Sample records for shorter operating time

  1. [Comparison of the results of laparotomy and laparoscopic surgery in patients with Crohn's disease].

    PubMed

    Horváth, Gyula; Simonka, Zsolt; Lázár, György

    2014-01-05

    Crohn's disease is an inflammatory bowel disease which may affect different parts of the gastrointestinal tract. To compare retrospectively the results of laparotomy and laparoscopic surgery performed in patients with Crohn's disease between January 1, 2005 and October 31, 2012 in the Department of Surgery, University of Szeged, Hungary. Patients were divided into two groups based on the types of surgery; 103 patients underwent laparotomy and 30 patients had laparoscopic surgery programmed. 22 patients had 24 primary acute interventions. The mean age was significantly lower in the laparoscopic surgery group (p = 0.042). The laparoscopic ileocecal resections have been found significantly shorter than laparotomies (p = 0.033). When ileocecal resection was performed the operation time was significantly longer (p = 0.033) while hospitalization time (p = 0.025) and intensive care unit treatment time (p<0.001) were shorter and the bowel passage also started earlier in the laparoscopic group as compared to the laparotomy group. Laparoscopic surgery results in smaller surgical trauma, better cosmetic outcome, shorter hospitalization time and not higher complication- and morbidity-rate as well as shorter operation time in certain cases. However, it requires more qualified surgical team and the operation expenses are higher.

  2. Stapled haemorrhoidopexy for the treatment of haemorrhoids: a systematic review.

    PubMed

    Burch, J; Epstein, D; Sari, A Baba-Akbari; Weatherly, H; Jayne, D; Fox, D; Woolacott, N

    2009-03-01

    This systematic review aimed to evaluate the short- and long-term safety, efficacy and costs of stapled haemorrhoidopexy (SH) compared with conventional haemorrhoidectomy. We searched 26 electronic databases and websites for studies in any language up to July 2006. Inclusion criteria were predefined, and each stage of the review process was conducted in duplicate. Twenty-seven randomized controlled trials were included (n = 2279). All had some methodological flaws. Postoperatively, 19 trials (95%) reported less pain, 17 (89%) reported a shorter operating time, 14 (88%) a shorter hospital stay, and 14 (93%) a shorter convalescence time following SH. However, prolapse was significantly more common after SH (OR 3.38; 95% CI: 1.00, 11.47). In the longer term, prolapse was significantly more common after SH (OR 4.34; 95% CI: 1.67, 11.28) as was reintervention for prolapse (OR 6.78; 95% CI: 2.00, 23.00). There were no differences in the rate or type of complications. Conventional haemorrhoidectomy and SH had similar costs during the initial admission. Compared with conventional haemorrhoidectomy, SH resulted in less postoperative pain, shorter operating time, a shorter hospital stay, and a shorter convalescence, but a higher rate of prolapse and reintervention for prolapse.

  3. [A comparison of laparoscopic versus open repair for the surgical treatment of perforated peptic ulcers].

    PubMed

    Domínguez-Vega, Gerardo; Pera, Manuel; Ramón, José M; Puig, Sonia; Membrilla, Estela; Sancho, Joan; Grande, Luis

    2013-01-01

    To analyse the outcomes of laparoscopic versus open repair for perforated peptic ulcers (PPU). All patients undergoing PPU repair between January 2002 and March 2012 were included in the study. Demographic characteristics, operation time, complications, and length of hospital stay were evaluated. Two hundred and twelve patients (median age, 49 years) were included, 60 in the laparoscopic group and 52 in the open group. Patients operated laparoscopically were significantly younger and had a higher consumption of tobacco, alcohol and cannabis. Median acute symptoms time was shorter in the laparoscopic group (6h) compared to the open group (12h; P=.025) Symptoms time was shorter in the laparoscopic group. Median operating time was significantly longer in the laparoscopic group (104.5min vs. 76min, P=.025). The percentage of conversion to open repair was 25%. There was no difference in morbidity between 2 groups, but there were 3 deaths in the open group. Median hospital stay was significantly shorter in patients treated laparoscopically when compared with the open group (6 days vs. 8 days; P=.041). Laparoscopic and open repair are equally safe in the management of PPU. A shorter hospital stay can be achieved in the laparoscopic group. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.

  4. 14 CFR 119.51 - Amending operations specifications.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... date proposed by the applicant for the amendment to become effective, unless a shorter time is approved... introduction of aircraft not before proven for use in air carrier or commercial operator operations. (ii) At...

  5. Short Operative Duration and Surgical Site Infection Risk in Hip and Knee Arthroplasty Procedures

    PubMed Central

    Dicks, Kristen V.; Baker, Arthur W.; Durkin, Michael J.; Anderson, Deverick J.; Moehring, Rebekah W.; Chen, Luke F.; Sexton, Daniel J.; Weber, David J.; Lewis, Sarah S.

    2016-01-01

    OBJECTIVE To determine the association (1) between shorter operative duration and surgical site infection (SSI) and (2) between surgeon median operative duration and SSI risk among first-time hip and knee arthroplasties. DESIGN Retrospective cohort study SETTING A total of 43 community hospitals located in the southeastern United States. PATIENTS Adults who developed SSIs according to National Healthcare Safety Network criteria within 365 days of first-time knee or hip arthroplasties performed between January 1, 2008 and December 31, 2012. METHODS Log-binomial regression models estimated the association (1) between operative duration and SSI outcome and (2) between surgeon median operative duration and SSI outcome. Hip and knee arthroplasties were evaluated in separate models. Each model was adjusted for American Society of Anesthesiology score and patient age. RESULTS A total of 25,531 hip arthroplasties and 42,187 knee arthroplasties were included in the study. The risk of SSI in knee arthroplasties with an operative duration shorter than the 25th percentile was 0.40 times the risk of SSI in knee arthroplasties with an operative duration between the 25th and 75th percentile (risk ratio [RR], 0.40; 95% confidence interval [CI], 0.38–0.56; P <.01). Short operative duration did not demonstrate significant association with SSI for hip arthroplasties (RR, 1.04; 95% CI, 0.79–1.37; P =.36). Knee arthroplasty surgeons with shorter median operative durations had a lower risk of SSI than surgeons with typical median operative durations (RR, 0.52; 95% CI, 0.43–0.64; P <.01). CONCLUSIONS Short operative durations were not associated with a higher SSI risk for knee or hip arthroplasty procedures in our analysis. PMID:26391277

  6. Anterior Cervical Corpectomy with free vascularized fibular graft versus multilevel discectomy and grafting for Cervical Spondylotic Myelopathy

    PubMed Central

    Addosooki, Ahmad I; El-deen, Mohamed Alam

    2015-01-01

    Purpose A retrospective study to compare the radiologic and clinical outcomes of 2 different anterior approaches, multilevel anterior cervical discectomy with fusion (ACDF) using autologus ticortical bone graft versus anterior cervical corpectomy with fusion (ACCF) using free vascularized fibular graft (FVFG) for the management of cervical spondylotic myelopathy(CSM). Methods A total of 15 patients who underwent ACDF or ACCF using FVFG for multilevel CSM were divided into two groups. Group A (n = 7) underwent ACDF and group B (n = 8) ACCF. Clinical outcomes using Japanese Orthopaedic Association (JOA) score, perioperative parameters including operation time and hospital stay, radiological parameters including fusion rate and cervical lordosis, and complications were compared. Results Both group A and group B demonstrated significant increases in JOA scores. Patients who underwent ACDF experienced significantly shorter operation times and hospital stay. Both groups showed significant increases in postoperative cervical lordosis and achieved the same fusion rate (100 %). No major complications were encountered in both groups. Conclusion Both ACDF and ACCF using FVFG provide satisfactory clinical outcomes and fusion rates for multilevel CSM. However, multilevel ACDF is associated with better radiologic parameters, shorter hospital stay and shorter operative times. PMID:26767152

  7. Is da Vinci Xi Better than da Vinci Si in Robotic Rectal Cancer Surgery? Comparison of the 2 Generations of da Vinci Systems.

    PubMed

    Ozben, Volkan; Cengiz, Turgut B; Atasoy, Deniz; Bayraktar, Onur; Aghayeva, Afag; Erguner, Ilknur; Baca, Bilgi; Hamzaoglu, Ismail; Karahasanoglu, Tayfun

    2016-10-01

    We aimed to compare perioperative outcomes for procedures using the latest generation of da Vinci robot versus its previous version in rectal cancer surgery. Fifty-three patients undergoing robotic rectal cancer surgery between January 2010 and March 2015 were included. Patients were classified into 2 groups (Xi, n=28 vs. Si, n=25) and perioperative outcomes were analyzed. The groups had significant differences including operative procedure, hybrid technique and redocking (P>0.05). In univariate analysis, the Xi group had shorter console times (265.7 vs. 317.1 min, P=0.006) and total operative times (321.6 vs. 360.4 min, P=0.04) and higher number of lymph nodes harvested (27.5 vs. 17.0, P=0.008). In multivariate analysis, Xi robot was associated with a shorter console time (odds ratio: 0.09, P=0.004) with no significant differences regarding other outcomes. Both generations of da Vinci robot led to similar short-term outcomes in rectal cancer surgery, but the Xi robot allowed shorter console times.

  8. [Comparison of the application between circular stapler and linear stapler in Billroth II( anastomosis of distal gastrectomy].

    PubMed

    Zhang, Nan; Su, Xiangqian; Xu, Kai

    2018-02-25

    To compare the safety and effectiveness of circular stapler and linear stapler in Billroth II( anastomosis following distal gastrectomy for gastric cancer patients. Clinical data of gastric adenocarcinoma patients who received distal gastrectomy with Billroth II( anastomosis at Ward IIII( of Gastrointestinal Cancer Center of Peking University Cancer Hospital from January 2013 to April 2017 were collected retrospectively. (1) patients identified as stage IIII( gastric cancer by preoperative clinical and postoperative pathological staging. (2) patients undergoing emergency operation due to perforation, obstruction, or bleeding of digestive tract. (3) patients receiving chemotherapy before operation. (4) patients undergoing combined organ resection due to tumor involving other organs. (5) patients complicating with other malignancies. A total of 116 cases were enrolled and divided into circular stapler (CS, 61 cases) group and linear stapler (LS, 55 cases) group according to the application of mechanical stapler. Clinicopathological characteristics, operative conditions and postoperative recovery were compared between two groups. Differences in baseline data, such as tumor size, Lauren classification, differentiation grade, and pathologic stage, between two groups were not statistically significant (all P>0.05). The mean operative time (230 min vs. 234 min), median intra-operative blood loss (50.0 ml vs. 50.0 ml), median number of harvested lymph node (28.0 vs. 26.0) and median number of positive lymph node (1.0 vs. 2.0) between LS group and CS group were not significantly different (all P>0.05) As compared to CS group, LS group presented shorter median time to the first flatus (3.0 days vs. 4.0 days, P=0.038), shorter median time to the first liquid diet (7.0 days vs. 8.0 days, P=0.000), shorter median time to remove the first abdominal drainage tube (7.0 days vs. 9.0 days, P=0.000) and shorter median time of postoperative hospital stay (8.0 days vs. 10.0 days, P=0.000). The morbidity of postoperative complication was 11.5% and 1.8% in CS group and LS group respectively without significant difference (P=0.092). In CS group, 1 case (1.6%) developed anastomotic hemorrhage, 3 cases (4.9%) gastric emptying disorder and 3 cases (4.9%) abdominal infection after operation, who all were cured by conservative treatment without duodenal stump fistula and re-operation. In LS group, only 1 case (1.8%) developed duodenal stump fistula and was cured by re-operation. In distal gastrectomy with Billroth II( anastomosis for gastric cancer, the application of linear stapler results in faster recovery of gastrointestinal function and shorter hospital stay, indicating more advantages.

  9. [Coronary bypass in treatment of high-risk patients].

    PubMed

    Avdagić, Harun; Mujanović, Emir; Mesanović, Nihad; Sijereić-Avdagić, Selma; Pirić, Melika

    2009-01-01

    Although it is possible to find a number of comparative studies in the world literature discussing the results of coronary artery bypass surgery (CABG) with and without cardiopulmonary bypass (CPB), until now such analysis has not been made in Bosnia and Herzegovina. The main aim of this scientific work was to compare morbidity and mortality, need for blood transfusions, length of stay in the intensive care unit, total length of hospitalisation and number of complication in two groups of patients operated with these methods. Patients with EuroScore > or =5 with CABG operated in Cardiovascular Clinic Tuzla, from May 2000 to May 2005 divided in two groups, were included in this study. There were 100 patients in the first group operated with CPB and 100 patients in the second group operated without CPB. The average time spent on respirators was shorter in patients operated without CPB (3.7 vs.9.74 hours, p = 0.023) and the time spent in Intensive care shorter too (19 vs. 23 days, p = 0.008). Volume of postoperative bleeding was less in patients operated without CPB (574.9 vs. 988.9 ml, p = 0.038), as volume after blood transfusion (168.8 vs. 350.3 mi, p = 0.001). Intraoperative inotrope support was less in patients operated without CPB (8.0 vs. 19.0%, p = 0.038) as postoperative inotrope support (6.0 vs. 17.0%, p = 0.027). The most usual postoperative complication was atrial fibrillation and there was no difference between patients operated with CPB and without CPB (24% vs. 17%, p = 0.293). Mortality was not different in patients operated with or without CPB (2.0% vs. 6.0%, p = 0.140). The average time of total hospitalisation was also shorter in patients operated without CPB (8.0 vs. 9.5 days, p = 0.039. In conclusion CABG without CPB has many advantages compared to the conventional method. Mortality and morbidity are reduced and there is less need for transfusion. The time spent on mechanical ventilation is reduced and less time is spent in intensive care. The total hospitalisation time is also reduced.

  10. May radiofrequency be the best choice for III-IV degree hemorrhoids?

    PubMed

    Milito, Giovanni; Lisi, Giorgio; Aronadio, Elena; Campanelli, Michela; Venditti, Dario; Grande, Simona; Grande, Michele

    2017-03-01

    Hemorrhoidectomy is considered the most efficient method to treat hemorrhoids of III and IV grades. The aim of this study was to compare conventional diathermy hemorrhoidectomy and radiofrequency hemorrhoidectomy based on a large series of patients. Between June 2001 and June 2014, 1000 patients have been treated with radiofrequency hemorrhoidectomy (group A) and 500 patients have been treated with diathermy (group B) as a day-case procedure. Operating time, postoperative pain score, hospital stay, early and late postoperative complications, wound healing time and time to return to normal activities were assessed. The mean follow-up was seven years. The mean operating time for radiofrequency hemorrhoidectomy was shorter than diathermy but not significantly. Patients treated with radiofrequency had significantly less postoperative pain (measured on a Visual Analogue Scale; P=0.001), a shorter wound healing time, less time off work and postoperative complications (P=0.001) than patients who had diathermy. Neither wound healing nor mean hospital stay (day-case surgery) was significantly different. Radiofrequency hemorrhoidectomyis a valid alternative to the conventional diathermy technique, due to the reduction of operative time, postoperative pain, early and late complication rate.

  11. Predictors of shorter sleep in early childhood

    PubMed Central

    McDonald, Laura; Wardle, Jane; Llewellyn, Clare H.; van Jaarsveld, Cornelia H.M.; Fisher, Abigail

    2014-01-01

    Objective The aim of this study was to identify socio-demographic and home environmental predictors of shorter sleep in early childhood, and to examine whether effects were mediated by the timing of bedtime or wake time. Methods Participants were from Gemini, a British birth cohort of twins, and included 1702 children; one randomly selected from each twin pair. Parents reported night-time sleep duration at an average age of 15.8 months (range 14–27 months) using a modified version of the Brief Infant Sleep Questionnaire. Multiple logistic regression models were used to identify predictors of shorter sleep for this study. Results Using a cut-off of <11 h a night, shorter sleep was reported in 14.1% of children. Lower maternal education, non-white ethnic background, being male, low birth weight, living in a home with >1 older child and watching >1 h of TV in the evening were independently associated with shorter sleep. Mediation analyses showed that associations between education, ethnicity, evening TV viewing and sleep were driven predominantly by later bedtimes, while sex differences were driven predominantly by earlier wake times in boys. Conclusion In this sample, multiple environmental factors were associated with shorter sleep in young children, with several operating predominantly through later bedtime. An emphasis on the importance of an early and consistent bedtime could help promote healthy sleep and reduce inequalities in child health. PMID:24726571

  12. Perioperative surgical outcome of conventional and robot-assisted total laparoscopic hysterectomy.

    PubMed

    van Weelden, W J; Gordon, B B M; Roovers, E A; Kraayenbrink, A A; Aalders, C I M; Hartog, F; Dijkhuizen, F P H L J

    2017-01-01

    To evaluate surgical outcome in a consecutive series of patients with conventional and robot assisted total laparoscopic hysterectomy. A retrospective cohort study was performed among patients with benign and malignant indications for a laparoscopic hysterectomy. Main surgical outcomes were operation room time and skin to skin operating time, complications, conversions, rehospitalisation and reoperation, estimated blood loss and length of hospital stay. A total of 294 patients were evaluated: 123 in the conventional total laparoscopic hysterectomy (TLH) group and 171 in the robot TLH group. After correction for differences in basic demographics with a multivariate linear regression analysis, the skin to skin operating time was a significant 18 minutes shorter in robot assisted TLH compared to conventional TLH (robot assisted TLH 92m, conventional TLH 110m, p0.001). The presence or absence of previous abdominal surgery had a significant influence on the skin to skin operating time as did the body mass index and the weight of the uterus. Complications were not significantly different. The robot TLH group had significantly less blood loss and lower rehospitalisation and reoperation rates. This study compares conventional TLH with robot assisted TLH and shows shorter operating times, less blood loss and lower rehospitalisation and reoperation rates in the robot TLH group.

  13. TVT-Exact and midurethral sling (SLING-IUFT) operative procedures: a randomized study

    PubMed Central

    Aniulis, Povilas; Skaudickas, Darijus

    2015-01-01

    Objectives The aim of the study is to compare results, effectiveness and complications of TVT exact and midurethral sling (SLING-IUFT) operations in the treatment of female stress urinary incontinence (SUI). Methods A single center nonblind, randomized study of women with SUI who were randomized to TVT-Exact and SLING-IUFT was performed by one surgeon from April 2009 to April 2011. SUI was diagnosed on coughing and Valsalva test and urodynamics (cystometry and uroflowmetry) were assessed before operation and 1 year after surgery. This was a prospective randomized study. The follow up period was 12 months. 76 patients were operated using the TVT-Exact operation and 78 patients – using the SLING-IUFT operation. There was no statistically significant differences between groups for BMI, parity, menopausal status and prolapsed stage (no patients had cystocele greater than stage II). Results Mean operative time was significantly shorter in the SLING-IUFT group (19 ± 5.6 min.) compared with the TVT-Exact group (27 ± 7.1 min.). There were statistically significant differences in the effectiveness of both procedures: TVT-Exact – at 94.5% and SLING-IUFT – at 61.2% after one year. Hospital stay was statistically significantly shorter in the SLING-IUFT group (1. 2 ± 0.5 days) compared with the TVT-Exact group (3.5 ± 1.5 days). Statistically significantly fewer complications occurred in the SLING-IUFT group. Conclusion the TVT-Exact and SLING-IUFT operations are both effective for surgical treatment of female stress urinary incontinence. The SLING-IUFT involved a shorter operation time and lower complications rate., the TVT-Exact procedure had statistically significantly more complications than the SLING-IUFT operation, but a higher effectiveness. PMID:28352711

  14. TVT-Exact and midurethral sling (SLING-IUFT) operative procedures: a randomized study.

    PubMed

    Aniuliene, Rosita; Aniulis, Povilas; Skaudickas, Darijus

    2015-01-01

    The aim of the study is to compare results, effectiveness and complications of TVT exact and midurethral sling (SLING-IUFT) operations in the treatment of female stress urinary incontinence (SUI). A single center nonblind, randomized study of women with SUI who were randomized to TVT-Exact and SLING-IUFT was performed by one surgeon from April 2009 to April 2011. SUI was diagnosed on coughing and Valsalva test and urodynamics (cystometry and uroflowmetry) were assessed before operation and 1 year after surgery. This was a prospective randomized study. The follow up period was 12 months. 76 patients were operated using the TVT-Exact operation and 78 patients - using the SLING-IUFT operation. There was no statistically significant differences between groups for BMI, parity, menopausal status and prolapsed stage (no patients had cystocele greater than stage II). Mean operative time was significantly shorter in the SLING-IUFT group (19 ± 5.6 min.) compared with the TVT-Exact group (27 ± 7.1 min.). There were statistically significant differences in the effectiveness of both procedures: TVT-Exact - at 94.5% and SLING-IUFT - at 61.2% after one year. Hospital stay was statistically significantly shorter in the SLING-IUFT group (1. 2 ± 0.5 days) compared with the TVT-Exact group (3.5 ± 1.5 days). Statistically significantly fewer complications occurred in the SLING-IUFT group. the TVT-Exact and SLING-IUFT operations are both effective for surgical treatment of female stress urinary incontinence. The SLING-IUFT involved a shorter operation time and lower complications rate., the TVT-Exact procedure had statistically significantly more complications than the SLING-IUFT operation, but a higher effectiveness.

  15. Hand-assisted laparoscopic versus robot-assisted laparoscopic partial nephrectomy: comparison of short-term outcomes and cost.

    PubMed

    Elsamra, Sammy E; Leone, Andrew R; Lasser, Michael S; Thavaseelan, Simone; Golijanin, Dragan; Haleblian, George E; Pareek, Gyan

    2013-02-01

    Robot-assisted laparoscopic partial nephrectomy (RALPN) and laparoscopic partial nephrectomy (LPN) have become standard for the surgical management of small renal masses (SRMs). However, no studies have evaluated the short-term outcomes or cost of RALPN as compared with hand-assisted laparoscopic partial nephrectomy (HALPN) in a standardized fashion. A retrospective review of all patients who underwent HALPN or RALPN from 2006 to 2010 were assessed for patient age, body mass index (BMI), American Society of Anesthesiologists (ASA) score, radiographic tumor size, nephrometry (radius, endo/exophytic, nearness to collecting system, anterior/posterior, lines of polarity [RENAL]) scores, operative and room times, hospital length of stay (LOS), estimated blood loss (EBL), requirement of hilar vessel clamping, warm ischemia time (WIT), pre- and postprocedural creatinine and hemoglobin levels, and complications. Total costs of the procedures were estimated based on operating room component (operative staff time, anesthesia, and supply) and hospital stay cost (room and board, pharmacy). A robotic premium cost, estimated based on the yearly overall cost of the da Vinci S surgical system divided by the annual number of cases, was included in the RALPN cost. Cost figures were obtained from hospital administration and applied to the mean HALPN and RALPN patient. Forty-seven patients underwent HALPN since 2006 and 21 patients underwent RALPN since 2008. ASA, BMI, EBL, tumor size, nephrometry score, positive margin rate, change in creatinine, change in hemoglobin, morphine equivalents used, and complication rate were all similar in both groups (p>0.05). Room time and operative time were significantly shorter for the HALPN cohort (p=0.001) whereas LOS was significantly shorter in the RALPN cohort (p=0.019). Despite the shorter LOS, RALPN was associated with a $1165 increased cost, mainly due to increased operating room time and premium cost of the robot. While early in our experience, RALPN offered no significant advantage in short-term outcomes over HALPN and was associated with an increased cost of over $1150.

  16. Comparison of fiber delivered CO2 laser and electrocautery in transoral robot assisted tongue base surgery.

    PubMed

    Karaman, Murat; Gün, Taylan; Temelkuran, Burak; Aynacı, Engin; Kaya, Cem; Tekin, Ahmet Mahmut

    2017-05-01

    To compare intra-operative and post-operative effectiveness of fiber delivered CO 2 laser to monopolar electrocautery in robot assisted tongue base surgery. Prospective non-randomized clinical study. Twenty moderate to severe obstructive sleep apnea (OSA) patients, non-compliant with Continuous Positive Airway Pressure (CPAP), underwent Transoral Robotic Surgery (TORS) using the Da Vinci surgical robot in our University Hospital. OSA was treated with monopolar electrocautery in 10 patients, and with flexible CO 2 laser fiber in another 10 patients. The following parameters in the two sets are analyzed: Intraoperative bleeding that required cauterization, robot operating time, need for tracheotomy, postoperative self-limiting bleeding, length of hospitalization, duration until start of oral intake, pre-operative and post-operative minimum arterial oxygen saturation, pre-operative and post-operative Epworth Sleepiness Scale score, postoperative airway complication and postoperative pain. Mean follow-up was 12 months. None of the patients required tracheotomy and there were no intraoperative complications related to the use of the robot or the CO 2 laser. The use of CO 2 laser in TORS-assisted tongue base surgery resulted in less intraoperative bleeding that required cauterization, shorter robot operating time, shorter length of hospitalization, shorter duration until start of oral intake and less postoperative pain, when compared to electrocautery. Postoperative apnea-hypopnea index scores showed better efficacy of CO 2 laser than electrocautery. Comparison of postoperative airway complication rates and Epworth sleepiness scale scores were found to be statistically insignificant between the two groups. The use of CO 2 laser in robot assisted tongue base surgery has various intraoperative and post-operative advantages when compared to monopolar electrocautery.

  17. Modified gastroduodenostomy in laparoscopy-assisted distal gastrectomy: a 'tornado' anastomosis.

    PubMed

    Kubota, Keisuke; Kuroda, Junko; Yoshida, Masashi; Okada, Akihiro; Nitori, Nobuhiro; Kitajima, Masaki

    2013-01-01

    This study was to examine the utility of a modified double-stapling end-to-end gastroduodenostomy method ('Tornado' anastomosis) compared to a method with an additional gastrotomy ('Anterior Incision' method) in laparoscopy-assisted distal gastrectomy. Forty-two patients with gastric cancer who underwent laparoscopy-assisted distal gastrectomy were analyzed retrospectively. Billroth-I using an additional gastrotomy was performed in 24 patients (AI group) and Billroth-I without an additional gastrotomy was performed in 18 (TOR group). Clinicopathological features, operative outcomes (lymph node dissection, operative time, operative blood loss) and postoperative outcomes (complications, postoperative hospital stay, and body weight loss at one year after surgery) were evaluated and compared between groups. Operative time was significantly shorter in the TOR group (251 min) than in the AI group (282 min) (p < 0.01). There were no statistically significant differences in operative blood loss, postoperative complications, and hospital stay between the 2 study groups. Body weight loss at one year after surgery was -5.8 kg in the TOR group and -6.5 kg in the AI group, without a statistically significant difference. Completion time for Billroth-I anastomosis was significantly shorter with Tornado anastomosis than with the Anterior Incision method, with safety equal between the two methods.

  18. Outcome after introduction of laparoscopic appendectomy in children: A cohort study.

    PubMed

    Svensson, Jan F; Patkova, Barbora; Almström, Markus; Eaton, Simon; Wester, Tomas

    2016-03-01

    Acute appendicitis in children is common and the optimal treatment modality is still debated, even if recent data suggest that laparoscopic surgery may result in shorter postoperative length of stay without an increased number of complications. The aim of the study was to compare the outcome of open and laparoscopic appendectomies during a transition period. This was a retrospective cohort study with prospectively collected data. All patients who underwent an operation for suspected appendicitis at the Astrid Lindgren Children's Hospital in Stockholm between 2006 and 2010 were included in the study. 1745 children were included in this study, of whom 1010 had a laparoscopic intervention. There were no significant differences in the rate of postoperative abscesses, wound infections, readmissions or reoperations between the two groups. The median operating time was longer for laparoscopic appendectomy than for open appendectomy, 51 vs. 37minutes (p<0.05). The postoperative length of stay was similar in the two groups. A simple comparison between the groups suggested that laparoscopic appendectomy had a shorter median postoperative length of stay, 43 vs. 57hours (p<0.05). However, there was a trend in time for a shorter postoperative length of stay, and a trend for more of the procedures to be performed laparoscopically over time so on regression analysis, the apparent decrease in length of stay with laparoscopy could be ascribed to the general trend toward decreased length of stay over time, with no specific additional effect of laparoscopy. Our data show no difference in outcome between open and laparoscopic surgery for acute appendicitis in children in regard of complications. The initial assumption that the patients treated with laparoscopic surgery had a shorter postoperative stay was not confirmed with linear regression, which showed that the assumed difference was due only to a trend toward shorter postoperative length of stay over time, regardless of the surgical intervention. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Comparison of short-term outcomes between laparoscopic-assisted and open complete mesocolic excision (CME) for the treatment of transverse colon cancer.

    PubMed

    Wang, Yong; Zhang, Chuan; Feng, Yi-Fei; Fu, Zan; Sun, Yue-Ming

    2017-02-01

    Colorectal cancer (CRC) is the third most common cancer worldwide. Although laparoscopic-assisted complete mesocolic excision (LCME) is a superior treatment, there are few studies available on it owe to the low incidence and technical difficulty of LCME in transverse colon cancer. The clinical data of 78 patients with transverse colon cancer who were treated by LCME and open complete mesocolic excision (OCME) were retrospectively analyzed. A total of 39 cases had been treated by LCME, compared with 39 cases treated by OCME. The patient characteristics and short-term outcomes including operation time, intra-operative blood loss, length of incision, time to first flatus, first postoperative ambulation, postoperative hospitalization time, number of harvested lymph nodes, length of resected specimen and incidence of complications were evaluated. There was no case converted to OCME in LCME group. LCME had significantly shorter length of incision, shorter operation time, less intra-operative blood loss, shorter postoperative hospitalization time (P<0.05). The length of resected specimen and the numbers of harvested lymph nodes were (26.5±5.4 cm) and (16.2±3.1) in LCME group, and (24.8±4.9 cm) and (15.1±3.5) in OCME group, with no differences between two groups. The incidence of wound infection was lower while the incidence of lymphatic leakage, anastomotic leakage, urinary tract infection and wound dehiscence had no significant differences between two groups. None of patients in these two groups developed urinary retention, anastomotic bleeding and postoperative intestinal obstruction. Our findings suggested that LCME is a safe, feasible and effective treatment method for the treatment of transverse colon cancer due to it can provide superior short-term outcomes including less intra-operative blood loss, faster recovery and lower incidence of wound infection.

  20. A randomised controlled trial of coblation, diode laser and cold dissection in paediatric tonsillectomy.

    PubMed

    Elbadawey, M R; Hegazy, H M; Eltahan, A E; Powell, J

    2015-11-01

    This study aimed to compare the efficacy of diode laser, coblation and cold dissection tonsillectomy in paediatric patients. A total of 120 patients aged 10-15 years with recurrent tonsillitis were recruited. Participants were prospectively randomised to diode laser, coblation or cold dissection tonsillectomy. Operative time and blood loss were recorded. Pain was recorded on a Wong-Baker FACES(®) pain scale. The operative time (10 ± 0.99 minutes), blood loss (20 ± 0.85 ml) and pain were significantly lower with coblation tonsillectomy than with cold dissection tonsillectomy (20 ± 1.0 minutes and 30 ± 1.0 ml; p = 0.0001) and diode laser tonsillectomy (15 ± 0.83 minutes and 25 ± 0.83 ml; p = 0.0001). Diode laser tonsillectomy had a shorter operative time (p = 0.0001) and less blood loss (p = 0.001) compared with cold dissection tonsillectomy. However, at post-operative day seven, the diode laser tonsillectomy group had significantly higher pain scores compared with the cold dissection (p = 0.042) and coblation (p = 0.04) tonsillectomy groups. Both coblation and diode laser tonsillectomy are associated with significantly reduced blood loss and shorter operative times compared with cold dissection tonsillectomy. However, we advocate coblation tonsillectomy because of the lower post-operative pain scores compared with diode laser and cold dissection tonsillectomy.

  1. Robotic assisted versus pure laparoscopic surgery of the adrenal glands: a case-control study comparing surgical techniques.

    PubMed

    Morelli, Luca; Tartaglia, Dario; Bronzoni, Jessica; Palmeri, Matteo; Guadagni, Simone; Di Franco, Gregorio; Gennai, Andrea; Bianchini, Matteo; Bastiani, Luca; Moglia, Andrea; Ferrari, Vincenzo; Fommei, Enza; Pietrabissa, Andrea; Di Candio, Giulio; Mosca, Franco

    2016-11-01

    The role of the da Vinci Robotic System ® in adrenal gland surgery is not yet well defined. The goal of this study was to compare robotic-assisted surgery with pure laparoscopic surgery in a single center. One hundred and 16 patients underwent minimally invasive adrenalectomies in our department between June 1994 and December 2014, 41 of whom were treated with a robotic-assisted approach (robotic adrenalectomy, RA). Patients who underwent RA were matched according to BMI, age, gender, and nodule dimensions, and compared with 41 patients who had undergone laparoscopic adrenalectomies (LA). Statistical analysis was performed using the Student's t test for independent samples, and the relationship between the operative time and other covariates were evaluated with a multivariable linear regression model. P < 0.05 was considered significant. Mean operative time was significantly shorter in the RA group compared to the LA group. The subgroup analysis showed a shorter mean operative time in the RA group in patients with nodules ≥6 cm, BMI ≥ 30 kg/m 2 and in those who had previous abdominal surgery (p < 0.05). Results from the multiple regression model confirmed a shorter mean operative time with RA with nodules ≥6 cm (p = 0.010). Conversion rate and postoperative complications were 2.4 and 4.8 % in the LA group and 0 and 4.8 % in the RA group. In our experience, RA shows potential benefits compared to classic LA, in particular on patients with nodules ≥6 cm, BMI ≥ 30 kg/m2, and with previous abdominal surgery.

  2. Sutureless versus Conventional Aortic Valve Replacement: Outcomes in 70 High-Risk Patients Undergoing Concomitant Cardiac Procedures.

    PubMed

    Hanedan, Muhammet Onur; Yuruk, Mehmet Ali; Parlar, Ali Ihsan; Ziyrek, Ugur; Arslan, Ali Kemal; Sayar, Ufuk; Mataraci, Ilker

    2018-02-01

    In elderly, high-risk surgical patients, sutureless aortic valve replacement (AVR) can often be an alternative to conventional AVR; shorter aortic cross-clamp and cardiopulmonary bypass times are the chief advantages. We compared the outcomes of sutureless AVR with those of conventional AVR in 70 elderly patients who underwent concomitant cardiac surgical procedures. We retrospectively analyzed the cases of 42 men and 28 women (mean age, 70.4 ± 10.3 yr; range, 34-93 yr) who underwent cardiac operations plus AVR with either a sutureless valve (group 1, n=38) or a conventional bioprosthetic or mechanical valve (group 2, n=32). Baseline patient characteristics were similar except for worse New York Heart Association functional status and the prevalence of diabetes mellitus in group 1. In group 1, the operative, cross-clamp, and cardiopulmonary bypass times were shorter (all P =0.001), postoperative drainage amounts were lower ( P =0.009), hospital stays were shorter ( P =0.004), and less red blood cell transfusion was needed ( P =0.037). Echocardiograms before patients' discharge from the hospital showed lower peak and mean aortic gradients in group 1 (mean transvalvular gradient, 8.4 ± 2.8 vs 12.2 ± 5.2 mmHg; P =0.012). We found that elderly, high-risk patients who underwent multiple cardiac surgical procedures and sutureless AVR had better hemodynamic outcomes and shorter ischemic times than did patients who underwent conventional AVR.

  3. Turbulent transport measurements with a laser Doppler velocimeter.

    NASA Technical Reports Server (NTRS)

    Edwards, R. V.; Angus, J. C.; Dunning, J. W., Jr.

    1972-01-01

    The power spectrum of phototube current from a laser Doppler velocimeter operating in the heterodyne mode has been computed. The spectral width and shape predicted by the theory are in agreement with experiment. For normal operating parameters the time-average spectrum contains information only for times shorter than the Lagrangian-integral time scale of the turbulence. To examine the long-time behavior, one must use either extremely small scattering angles, much-longer-wavelength radiation, or a different mode of signal analysis, e.g., FM detection.

  4. Laparoscopic versus open incisional hernia repair: a retrospective cohort study with costs analysis on 269 patients.

    PubMed

    Soliani, G; De Troia, A; Portinari, M; Targa, S; Carcoforo, P; Vasquez, G; Fisichella, P M; Feo, C V

    2017-08-01

    To compare clinical outcomes and institutional costs of elective laparoscopic and open incisional hernia mesh repairs and to identify independent predictors of prolonged operative time and hospital length of stay (LOS). Retrospective observational cohort study on 269 consecutive patients who underwent elective incisional hernia mesh repair, laparoscopic group (N = 94) and open group (N = 175), between May 2004 and July 2014. Operative time was shorter in the laparoscopic versus open group (p < 0.0001). Perioperative morbidity and mortality were similar in the two groups. Patients in the laparoscopic group were discharged a median of 2 days earlier (p < 0.0001). At a median follow-up over 50 months, no difference in hernia recurrence was detected between the groups. In laparoscopic group total institutional costs were lower (p = 0.02). At Cox regression analysis adjusted for potential confounders, large wall defect (W3) and higher operative risk (ASA score 3-4) were associated with prolonged operative time, while midline hernia site was associated with increased hospital LOS. Open surgical approach was associated with prolongation of both operative time and LOS. Laparoscopic approach may be considered safely to all patients for incisional hernia repair, regardless of patients' characteristics (age, gender, BMI, ASA score, comorbidities) and size of the wall defect (W2-3), with the advantage of shorter operating time and hospital LOS that yields reduced total institutional costs. Patients with higher ASA score and large hernia defects are at risk of prolonged operative time, while an open approach is associated with longer duration of surgical operation and hospital LOS.

  5. [Coronary artery bypass grafting without use of cardiopulmonary bypass].

    PubMed

    Mujanović, Emir; Bergsland, Jacob; Hadziselimović, Mehdin; Softić, Muniba; Azabagic, Azur; Stanimirović-Mujanović, Sanja; Kabil, Emir

    2002-01-01

    Although it is possible to find a number of comparative studies in the world literature discussing the results of coronary artery bypass surgery (CABG) with and without cardiopulmonary bypass (CPB), until now such analysis has not been made in Bosnia and Herzegovina. The main aim of this scientific work was to compare morbidity and mortality, need for blood transfusions, length of stay in the intensive care unit and total length of hospitalisation in two groups of patients operated with these methods. One hundred and four patients with coronary artery disease operated in Cardiovascular Clinic Tuzla, from September, 1998 to September 2002 divided in two groups, were included in this study. There were 52 patients in the first group operated with CPB and 52 patients in the second group operated without CPB. The groups were matched for gender, age, ejection fraction and preoperative risk factors. The incidence of postoperative complications was lower in patients operated without CPB (5.77% vs. 21.15%). The mortality rate was reduced in patients operated without CPB (0.00% vs. 5.76%). There were reduced need for transfusion in patients operated without CPB (0.28 vs. 1.11 units of blood). The average time spent on respirators was shorter in patients operated without CPB (1.50 vs. 4.76 hours). The average time of total hospitalisation was also shorter in patients operated withouth CPB (6.53 vs. 8.13 days). In conclusion CABG without CPB has many advantages compared to the conventional method. Mortality and morbidity are reduced and there is less need for transfusion. The time spent on mechanical ventilation is reduced and less time is spent in intensive care and the total hospitalisation time is also less.

  6. Quantitative contrast-enhanced ultrasonography for the differential diagnosis of endometrial hyperplasia and endometrial neoplasms

    PubMed Central

    Liu, Ying; Xu, Yi; Cheng, Wen; Liu, Xinghan

    2016-01-01

    The present study aimed to investigate the feasibility of applying contrast-enhanced ultrasonography (CEUS) imaging technology for distinguishing between benign and malignant endometrial lesions, and to screen markers that could be correlated with the pathological results. In this study, endometrial diseases were diagnosed by biopsy under hysteroscopy and CEUS examinations. The intensity and time parameters of the time-intensity curve (TIC) were analyzed. The mean arrival time (AT), time-to-peak (TTP), rise time (RT), washout half-time and clearance half-time of malignant lesions were shorter than those of benign lesions (P<0.05), whereas the average peak intensity (PI) and enhancement intensity (EI) of malignant lesions were higher than those of benign lesions (P<0.05). The receiver operating characteristic curve showed the following cut-off values: PI, 29.2 dB; EI, 21.35 dB; AT, 12.75 sec; TTP, 26.75 sec; RT, 13.2 sec; clearance half-time, 89.3 sec; and washout half-time, 75.45 sec. The lesions with PI, an EI higher than that of the cut-off and lesions with an AT, TTP, RT, half clearing time and washout half-time shorter than the cut-off were considered malignant. The TTP, RT and half clearing time were negatively correlated with microvessel density (MVD), i.e., MVD was higher when the TTP, RT and half clearing time were shorter. Overall, changes in the enhancement and clearing of lesions could be quantitatively analyzed by CEUS TIC and further discriminate benign from malignant lesions. In the present study, CEUS appeared to indirectly reflect blood vessel changes inside the lesions and provided a pre-operative non-invasive fast imaging method for the diagnosis of endometrial disease. PMID:27895728

  7. 14 CFR 91.1017 - Amending program manager's management specifications.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... applicant for the amendment to become effective, unless a shorter time is approved, in cases such as mergers, acquisitions of operational assets that require an additional showing of safety (for example, proving tests or...

  8. Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusion. Invited submission from the Joint Section Meeting On Disorders of the Spine and Peripheral Nerves, March 2005.

    PubMed

    Wang, Jeremy C; Haid, Regis W; Miller, Jay S; Robinson, James C

    2006-02-01

    The authors present the early clinical results obtained in patients who underwent SPIRE spinous process plate fixation following anterior lumbar interbody fusion (ALIF). Between May 2003 and January 2005, 32 patients underwent titanium cage and bone morphogenetic protein-augmented ALIF and subsequent SPIRE (21 cases) or bilateral pedicle screw (BPS; 11 cases) fixation. Pedicle screws were implanted using either the open approach (three cases) or using a tubular retractor (eight cases). Patients' charts were reviewed for operative time, estimated blood loss (EBL), hospital length of stay (LOS), and evidence of pseudarthrosis or hardware failure. In SPIRE plate-treated patients, the median EBL (75 ml) was lower than in BPS-treated patients (open BPS [150 ml]; tubular BPS [125 ml]). The median operative time in SPIRE plate-treated patients was also shorter (164 minutes compared with 239 and 250 minutes in the open and tubular BPS, respectively). The median LOS was 3 days for both the SPIRE and tubular BPS groups, but 4 days in the open BPS group. There were no instances of major surgery-induced complication, pseudarthrosis, or hardware failure during mean follow-up periods of 5.5, 7.2, and 4.9 months in the SPIRE, open PS, and tubular BPS groups, respectively. The SPIRE plate is easy to implant and is associated with minimal operative risk. Compared with BPS/rod constructs, SPIRE plate fixation leads to less EBL and shorter operative time, without an increase in the rate of pseudarthrosis. Hospital LOS was also shorter in SPIRE plate-treated patients, which is consistent with the goals of minimal access spinal technologies.

  9. [Effect of actoprotectors on the work capacity of operators during modeling of various factors of space flight].

    PubMed

    Bobkov, Iu G; Epishkin, A K

    1988-01-01

    This paper presents experimental findings indicating that bemithyl, an actoprotective agent, has a beneficial effect on the health status and work capacity of operators during simulated space flight and 56-hour continuous work. The drug enhanced psychophysiological tolerance of the operators and improved the quality of their work: the quality of their compensatory tracking was on the average 10% higher, the number of errors of their porsuit tracking was 1.8 times lower, and the time of visual signal detection was 2.4 times shorter as compared to the placebo controls.

  10. Surgical team composition has a major impact on effectiveness and costs in laparoscopic donor nephrectomy.

    PubMed

    Özdemir-van Brunschot, Denise M D; Warlé, Michiel C; van der Jagt, Michel F; Grutters, Janneke P C; van Horne, Sharon B C E; Kloke, Heinrich J; van der Vliet, Johannes A; Langenhuijsen, Johan F; d'Ancona, Frank C

    2015-05-01

    Limited evidence exists that optimization of surgical team composition may improve effectiveness of laparoscopic donor nephrectomy (LDN). A retrospective cohort study with 541 consecutive LDNs. From 2003 to 2012, surgical team composition was gradually optimized with regard to the surgeons' experience, proficient assistance and the use of fixed teams. Multivariable analysis showed that a surgical team with an experienced surgeon had a significantly shorter operation time (OT) (-18 min, 95% CI -28 to -9), less estimated blood loss (EBL) (-64 mL, 95% CI -108 to -19) and shorter length of stay (LOS) (-1 day, 95% CI -1.6 to 0). Proficient assistance was also independently associated with a shorter OT (-43 min, 95% CI -53 to -33) and reduced EBL (-58 mL, 95% CI -109 to -6), whereas those procedures performed by fixed teams were related to a shorter operation (-50 min, 95% CI -59 to -43) and warm ischemia time (-1.8, 95% CI -2.1 to -1.5), a reduced mean complication grade (-0.14 per patient, 95% CI -0.3 to -0.02) and a shorter LOS (-1.1 day, 95% CI -1.7 to -05). Health care costs for LDN by one staff surgeon with unproficient assistance were 7.707 Euro, whereas costs for LDN by two staff surgeons in fixed teams were 5.614 Euro. Surgical team composition has a major impact on variables that reflect the effectiveness of LDN from the donors' perspective. Health care costs are lower for LDNs performed by two experienced surgeons in fixed team composition. We advocate the use of two experienced surgeons in fixed team composition for LDN.

  11. Conventional plate fixation method versus pre-operative virtual simulation and three-dimensional printing-assisted contoured plate fixation method in the treatment of anterior pelvic ring fracture.

    PubMed

    Hung, Chun-Chi; Li, Yuan-Ta; Chou, Yu-Ching; Chen, Jia-En; Wu, Chia-Chun; Shen, Hsain-Chung; Yeh, Tsu-Te

    2018-05-03

    Treating pelvic fractures remains a challenging task for orthopaedic surgeons. We aimed to evaluate the feasibility, accuracy, and effectiveness of three-dimensional (3D) printing technology and computer-assisted virtual surgery for pre-operative planning in anterior ring fractures of the pelvis. We hypothesized that using 3D printing models would reduce operation time and significantly improve the surgical outcomes of pelvic fracture repair. We retrospectively reviewed the records of 30 patients with pelvic fractures treated by anterior pelvic fixation with locking plates (14 patients, conventional locking plate fixation; 16 patients, pre-operative virtual simulation with 3D, printing-assisted, pre-contoured, locking plate fixation). We compared operative time, instrumentation time, blood loss, and post-surgical residual displacements, as evaluated on X-ray films, among groups. Statistical analyses evaluated significant differences between the groups for each of these variables. The patients treated with the virtual simulation and 3D printing-assisted technique had significantly shorter internal fixation times, shorter surgery duration, and less blood loss (- 57 minutes, - 70 minutes, and - 274 ml, respectively; P < 0.05) than patients in the conventional surgery group. However, the post-operative radiological result was similar between groups (P > 0.05). The complication rate was less in the 3D printing group (1/16 patients) than in the conventional surgery group (3/14 patients). The 3D simulation and printing technique is an effective and reliable method for treating anterior pelvic ring fractures. With precise pre-operative planning and accurate execution of the procedures, this time-saving approach can provide a more personalized treatment plan, allowing for a safer orthopaedic surgery.

  12. Computer tomography urography assisted real-time ultrasound-guided percutaneous nephrolithotomy on renal calculus.

    PubMed

    Fang, You-Qiang; Wu, Jie-Ying; Li, Teng-Cheng; Zheng, Hao-Feng; Liang, Guan-Can; Chen, Yan-Xiong; Hong, Xiao-Bin; Cai, Wei-Zhong; Zang, Zhi-Jun; Di, Jin-Ming

    2017-06-01

    This study aimed to assess the role of pre-designed route on computer tomography urography (CTU) in the ultrasound-guided percutaneous nephrolithotomy (PCNL) for renal calculus.From August 2013 to May 2016, a total of 100 patients diagnosed with complex renal calculus in our hospital were randomly divided into CTU group and control group (without CTU assistance). CTU was used to design a rational route for puncturing in CTU group. Ultrasound was used in both groups to establish a working trace in the operation areas. Patients' perioperative parameters and postoperative complications were recorded.All operations were successfully performed, without transferring to open surgery. Time of channel establishment in CTU group (6.5 ± 4.3 minutes) was shorter than the control group (10.0 ± 6.7 minutes) (P = .002). In addition, there was shorter operation time, lower rates of blood transfusion, secondary operation, and less establishing channels. The incidence of postoperative complications including residual stones, sepsis, severe hemorrhage, and perirenal hematoma was lower in CTU group than in control group.Pre-designing puncture route on CTU images would improve the puncturing accuracy, lessen establishing channels as well as improve the security in the ultrasound-guided PCNL for complex renal calculus, but at the cost of increased radiation exposure.

  13. The risk of shorter fasting time for pediatric deep sedation.

    PubMed

    Clark, Mathew; Birisci, Esma; Anderson, Jordan E; Anliker, Christina M; Bryant, Micheal A; Downs, Craig; Dalabih, Abdallah

    2016-01-01

    Current guidelines adopted by the American Academy of Pediatrics calls for prolonged fasting times before performing pediatric procedural sedation and analgesia (PSA). PSA is increasingly provided to children outside of the operating theater by sedation trained pediatric providers and does not require airway manipulation. We investigated the safety of a shorter fasting time compared to a longer and guideline compliant fasting time. We tried to identify the association between fasting time and sedation-related complications. This is a prospective observational study that included children 2 months to 18 years of age and had an American Society of Anesthesiologists physical status classification of I or II, who underwent deep sedation for elective procedures, performed by pediatric critical care providers. Procedures included radiologic imaging studies, electroencephalograms, auditory brainstem response, echocardiograms, Botox injections, and other minor surgical procedures. Subjects were divided into two groups depending on the length of their fasting time (4-6 h and >6 h). Complication rates were calculated and compared between the three groups. In the studied group of 2487 subjects, 1007 (40.5%) had fasting time of 4-6 h and the remaining 1480 (59.5%) subjects had fasted for >6 h. There were no statistically significant differences in any of the studied complications between the two groups. This study found no difference in complication rate in regard to the fasting time among our subjects cohort, which included only healthy children receiving elective procedures performed by sedation trained pediatric critical care providers. This suggests that using shorter fasting time may be safe for procedures performed outside of the operating theater that does not involve high-risk patients or airway manipulation.

  14. Laparoscopic versus open abdominal surgery in children with sickle cell disease is associated with a shorter hospital stay.

    PubMed

    Goers, Trudie; Panepinto, Julie; Debaun, Michael; Blinder, Morey; Foglia, Robert; Oldham, Keith T; Field, Joshua J

    2008-03-01

    Limited information exists comparing the post-operative complication rate of laparoscopic or open abdominal surgeries in children with sickle cell disease (SCD). The primary objective of this study was to compare the outcomes in children with SCD who required laparoscopic or open abdominal surgery for a cholecystectomy or splenectomy. We conducted a retrospective analysis of laparoscopic and open abdominal surgeries performed in children with SCD (ages 0-20 years) at two medical centers from 1984 to 2004. The primary outcome measures were the rates of post-operative pain and acute chest syndrome (ACS) episodes following laparoscopic or open abdominal surgery. The secondary outcome was length of hospital stay following surgery. We also examined the potential contribution of pre-operative (transfusion) and intra-operative factors (operating time, estimated blood loss, and end-operative temperature) to post-operative SCD-related complications. A total of 140 cases were identified, 98 laparoscopic and 42 open. Episodes of post-operative pain and ACS episodes were comparable between laparoscopic and open procedures (pain: 4% vs. 3%, P = 0.619; ACS: 5% vs. 5%, P = 0.933). Additionally, laparoscopic surgeries were associated with a significantly shorter hospital stay (2.9 vs. 5.4 days, 95% CI -3.7 to -1.4, P < 0.001). There was no difference in the number of hospital readmissions within 1 month of the surgery. For children with SCD who need a cholecystectomy or splenectomy, laparoscopy is the preferred strategy because of a shorter hospital stay with a similar complication rate compared to open surgeries. (c) 2007 Wiley-Liss, Inc.

  15. The University of Colorado OSO-8 spectrometer experiment. IV - Mission operations

    NASA Technical Reports Server (NTRS)

    Hansen, E. R.; Bruner, E. C., Jr.

    1979-01-01

    The remote operation of two high-resolution ultraviolet spectrometers on the OSO-8 satellite is discussed. Mission operations enabled scientific observers to plan observations based on current solar data, interact with the observing program using real- or near real-time data and commands, evaluate quick-look instrument data, and analyze the observations for publication. During routine operations, experiments were planned a day prior to their execution, and the data from these experiments received a day later. When a shorter turnaround was required, a real-time mode was available. Here, the real-time data and command links into the remote control center were used to evaluate experiment operation and make satellite pointing or instrument configuration changes with a 1-90 minute turnaround.

  16. Turbulent transport measurements with a laser Doppler velocimeter

    NASA Technical Reports Server (NTRS)

    Edwards, R. V.; Angus, J. C.; Dunning, J. W., Jr.

    1972-01-01

    The power spectrum of phototube current from a laser Doppler velocimeter operating in the heterodyne mode has been computed. The spectrum is obtained in terms of the space time correlation function of the fluid. The spectral width and shape predicted by the theory are in agreement with experiment. For normal operating parameters the time average spectrum contains information only for times shorter than the Lagrangian integral time scale of the turbulence. To examine the long time behavior, one must use either extremely small scattering angles, much longer wavelength radiation or a different mode of signal analysis, e.g., FM detection.

  17. Comparison of Single-Port Percutaneous Extraperitoneal Repair and Three-Port Mini-Laparoscopic Repair for Pediatric Inguinal Hernia.

    PubMed

    Korkmaz, Mevlit; Güvenç, B Haluk

    2018-03-01

    Laparoscopy has been widely used in surgical practice in pediatric age, and many techniques for laparoscopic hernia repair have been described till now. In this study, we compared two laparoscopic techniques performed by two surgeons; each surgeon practicing only one of the two techniques. A retrospective analysis was performed on the surgical charts, enrolling 71 patients with uncomplicated inguinal hernia. Patients were divided into two groups according to the type of surgery: (Group A, 24 patients aged 2 months-8 years) laparoscopic percutaneous internal ring suturing technique and (Group B, 47 patients aged 35 days-12 years) three-port mini-laparoscopic technique. The hernia sac was ligated at the level of internal ring, using nonabsorbable 4/0-3/0 suture. Any unexpected contralateral opening was repaired in the same manner for both groups. Follow-up period was 4 months-2 years and 9 months-8 years, respectively. Operative time and complications were analyzed. Operation time (19.58 ± 7.06 minutes versus 35.87 ± 10.34 minutes, P < .001) was shorter in the percutaneous repair group. However, when subdivided by unilateral and bilateral presentation, only unilateral operative time was shorter compared to three-port group. There were no recurrences in Group A, while two recurrences occurred in Group B during the learning curve period. A contralateral opening accompanied the presenting unilateral hernia in 3 cases for Group A and 16 for Group B. One patient had to be converted open resulting from epigastric vessel injury, and postop hydrocele formation was seen in another in Group A. No intraoperative complications were seen in Group B. The overall experience shows that laparoscopic repair is a reliable approach regardless of the chosen technique. Percutaneous repair seems to be a less invasive method with shorter operative time, but it is not free of complications according to this series.

  18. Endoscopic Endonasal Pituitary Surgery: Impact of Surgical Education on Operation Length and Patient Morbidity

    PubMed Central

    Dedhia, Raj C.; Lord, Christopher A.; Pinheiro-Neto, Carlos D.; Fernandez-Miranda, Juan C.; Wang, Eric W.; Gardner, Paul A.; Snyderman, Carl H.

    2012-01-01

    Objectives To determine the difference in operative times and associated complications for cases performed solely by attending-level surgeons versus cases assisted by surgeons-in-training for endoscopic endonasal pituitary surgeries. Design Retrospective chart review. Setting Tertiary-care academic medical center. Participants A total of 228 patients having undergone endoscopic endonasal pituitary surgery from 2005 to 2011. Main Outcome Measure Duration of surgery comparing attending only (AO) and trainee-assisted (TA) surgeries. Results Thirty-seven (19%) of 198 cases were identified as AO surgeries, the remaining 161 (81%) were TA. Operative times (minutes) for the AO group were significantly shorter than the TA group (149.1 ± 54.8 vs 219.5 ± 83.7, p < 0.001). The AO group had fewer intraoperative cerebrospinal fluid leaks (30% vs 39%, p = 0.318), decreased estimated blood loss (408 mL vs 523 mL, p = 0.176), fewer postoperative complications (27% vs 37%, p = 0.268), and shorter length of stay (3.5 vs 4.3 days, p = 0.294). Conclusions This is the first study in otolaryngology or neurosurgery to compare operative times and outcomes for AO versus TA cases at a single academic institution. Operative times were significantly decreased and a trend toward a decrease in patient morbidity was noted for cases performed solely by attendings. The valuation of teaching activities in the operating room is a necessary first step toward optimizing the allocation of resources and funding of surgical education. PMID:24294558

  19. [The Joel-Cohen (Misgav Ladach) method--a new surgical technic for cesarean section and gynecological laparotomy].

    PubMed

    Katsulov, A; Nedialkov, K; Koleva, Zh; Iankov, M; Tashkov, B; Iotov, T; Kirov, K; Genov, M; Rusinov, P; Doncheva, Zh; Grŭncharov, I

    2000-01-01

    The authors make a review on this problem for first time in Bulgarian literature and for the first time by us operated with the Misgav Ladach method--cesarean section. The authors describe 50 cases wit Ladach method and as control 20 with Pfannenstiel. The authors establish shorter duration of the operation-Si] and 56.3 min. respective in benefit for Misgav method; the babies were extracted at 5.5 and 12.3 min. respect. The mothers with Misgav had better prognosis at the time of dehospitalization.

  20. Achieving Ships Mission Flexibility Through Designing, Printing And Operating Unmanned Systems With Additive Manufacturing And Delayed Differentiation

    DTIC Science & Technology

    2016-09-01

    the UAV’s reliability in fulfilling the mission as well as the build- time of the UAV. 14. SUBJECT TERMS design , print and operate, DPO...previously. There are opportunities to work on the design of the UAV to reduce the cognitive workload of the service member and time required to “print” and...the need arises to tailor the UAV for the specific mission. The modification of an existing design is expected to take a much shorter time than the

  1. The influence of the different forms of appendix base closure on patient outcome in laparoscopic appendectomy: a randomized trial.

    PubMed

    Delibegović, Samir; Mehmedovic, Zlatan

    2018-05-01

    During laparoscopic appendectomy, the base of the appendix is usually secured by loop ligature or stapling device. Hem-o-lok and DS clips have been shown as alternative techniques. The aim of this study was to compare the clinical outcomes of various forms of securing the base of the appendix, in order to find the most suitable method. The study included 120 patients with acute appendicitis randomly divided into four groups with 30 patients in each. In the first group, the base of the appendix was secured using an Endoloop, in the second group using a stapling device, in the third group using Hem-o-lok, and in the fourth group using a DS clip. The primary outcome was overall morbidity following securing the base of the appendix. Secondary outcomes were time of application and operative procedure, total length of stay, and surgical outcome. No morbidity was recorded in any group. The time of application was significantly longer in the Endoloop group than in the Stapler (P < 0.0001), Hem-o-lok (P < 0.0001), and DS clips (P < 0.0001) groups. The time of application in the Stapler group was significantly shorter than in the Hem-o-lok (P < 0.0001) and the DS clips (P < 0.0001) groups. The time of the operative procedure was significantly longer in the Endoloop than in the Stapler group (P < 0.0001). The time of the operative procedure in the Stapler group was significantly shorter than in the DS clips group (P < 0.0001) but did not differ significantly from the Hem-o-lok group (P = 0.199). The time of the operative procedure in the Hem-o-lok group was significantly shorter than in the DS clips group (P = 0.044). All forms of closure of the appendix base are acceptable, but Hem-o-lok and DS clips have the best potential for further development, and will probably become the method of choice in securing the base of the appendix.

  2. Comparing the Efficiencies of Third Molar Surgeries With and Without a Dentist Anesthesiologist.

    PubMed

    Reebye, Uday; Young, S; Boukas, E; Davidian, E; Carnahan, J

    2017-01-01

    Two different anesthesia models were compared in terms of surgical duration, safer outcomes, and economic implications. Third molar surgeries performed with and without a separate dentist anesthesiologist were evaluated by a retrospective data analysis of the surgical operative times. For more difficult surgeries, substantially shorter operative times were observed with the dentist anesthesiologist model, leading to a more favorable surgical outcome. An example calculation is presented to demonstrate economic advantages of scheduling the participation of a dentist anesthesiologist for more difficult surgeries.

  3. Short- and long-term outcomes after enucleation of pancreatic tumors: An evidence-based assessment.

    PubMed

    Zhou, Yanming; Zhao, Min; Wu, Lupeng; Ye, Feng; Si, Xiaoying

    Enucleation of pancreatic tumors is rarely performed. The aim of this study was to evaluate the published evidence for its short- and long-term outcomes. PubMed (MEDLINE) and EMBASE databases were searched from 1990 to March 2016. Studies including at least ten patients who underwent enucleation of pancreatic lesions were included. Data on the outcomes were synthesized and meta-analyzed where appropriate. Twenty-seven studies involving 1316 patients were included in the systematic review. The postoperative mortality was 0.3%, and the postoperative morbidity was 50.3%, mainly represented by pancreatic fistula (38.1%). Endocrine insufficiency, exocrine insufficiency and tumor recurrence was observed in 2.4%, 1.1% and 2.3% of the patients respectively. Compared with typical resection, the operation time, blood loss, length of hospital stay, and the incidence of endocrine and exocrine insufficiency were all significantly reduced after enucleation. The occurrence of pancreatic fistula was significantly higher in enucleation group, but overall morbidity, the reoperation rate and mortality were comparable between the two groups. There was no significant difference in disease recurrence between the two groups. Compared with central pancreatectomy, enucleation had a shorter operation time, lower blood loss, less morbidity, and better pancreatic function. Compared with open enucleation, minimally invasive enucleation had a shorter operation time and a shorter length of hospital stay. Enucleation is an appropriate surgical procedure in selected patients with benign or low-malignant lesions of the pancreas. The benefits of minimally invasive approach need to be validated in further investigations with larger groups of patients. Copyright © 2016 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  4. [Comparison of minimally invasive extraction and traditional method in the extraction of impacted mandibular third molar].

    PubMed

    Xu, Fang; Zhang, Hui-Xia

    2016-10-01

    To compare minimally invasive extraction and traditional method in the extraction of impacted mandibular third molar. One hundred and sixty patients with impacted mandibular third molar were equally divided into two groups. Patients in the experimental group were treated with minimally invasive extraction, using implant machine and luxator, while patients in the control group were treated with traditional methods including use of orthodox chisel. The operation time, intraoperative and postoperative complications including deformation of extraction sockets, dry socket, limitation of mouth opening, pain and swelling, and fear were observed and compared between the two groups. The data were analyzed with SPSS18.0 software package. The operation time was (17.32±1.01) min in the experimental group, significantly shorter than the control group which was (33.46±1.12)min (P<0.05); significant difference was found in the incidence of root fracture, medium or severe tooth sockets deformation and incidence of psychological fear during operation between the control group and experimental group(P<0.05); the degree of mouth opening after surgery, the incidence of moderate or severe pain after surgery was significantly lower in the experimental than in the control group(P<0.05). Minimally invasive extraction of mandibular impacted wisdom tooth is better than traditional method, with shorter operation time and less intraoperative and postoperative complications, which should be widely applied in clinic.

  5. Robotic surgery start-up with a fellow as the console surgeon.

    PubMed

    Reinhardt, Susanne; Ifaoui, Inge Boetker; Thorup, Jorgen

    2017-08-01

    Owing to the encouraging data on fellowship training in robotic pyeloplasty and the documented benefits of robotic pyeloplasty, the aim of this study was to test the feasibility of starting up pediatric urological robotic surgery in a center with a limited case volume. The operative parameters and clinical outcome of the first 25 robotic pyeloplasties performed were compared to data on open and laparoscopic procedures from the previous 5 year period. The fellow was the only console surgeon. An experienced non-robotic pediatric urologist was supervising at the patient site. The learning curve was in accordance with previously published data on fellows. The median operating time in robotic surgery was 182 min and was significantly shorter than in laparoscopic surgery (median 250 min) and the postoperative inpatient length of stay was significantly shorter after robotic surgery (median 1 day) than after both laparoscopic (median 2 days) and open surgery (median 3.5 days). For robotic cases, postoperative renography showed either stable or increased function of the hydronephrotic kidney. The only complication was in one case with ureteral orifice edema after JJ-stent removal, requiring nephrostomy for 6 weeks. The benefits of overall shorter postoperative hospital stay after robotic pyeloplasty and faster operating time compared to the laparoscopic procedure are clearly in accordance with data from the recent literature. The fast learning curve for robotic pyeloplasty will allow pediatric urology fellowship programs to be integrated in the start-up phase of a pediatric robotic program even though the case material is limited. Operative success rates were in accordance with the gold standard of open surgery.

  6. Lengthening Temporalis Myoplasty for Single-Stage Smile Reconstruction in Children with Facial Paralysis.

    PubMed

    Panossian, Andre

    2016-04-01

    Free muscle transfer for dynamic smile reanimation in facial paralysis is not always predictable with regard to cosmesis. Hospital stays range from 5 to 7 days. Prolonged operative times, longer hospital stays, and excessive cheek bulk are associated with free flap options. Lengthening temporalis myoplasty offers single-stage smile reanimation with theoretical advantages over free tissue transfer. From 2012 to 2014, 18 lengthening temporalis myoplasties were performed in 14 children for smile reconstruction. A retrospective chart review was completed for demographics, operative times, length of hospital stay, and perioperative complications. Fourteen consecutive patients with complete facial paralysis were included. Four patients underwent single-stage bilateral reconstruction, and 10 underwent unilateral procedures. Diagnoses included Möbius syndrome (n = 5), posterior cranial fossa tumors (n = 4), posttraumatic (n = 2), hemifacial microsomia (n = 1), and idiopathic (n = 2). Average patient age was 10.1 years. Average operative time was 410 minutes (499 minutes for bilateral lengthening temporalis myoplasty and 373 for unilateral lengthening temporalis myoplasty). Average length of stay was 3.3 days (4.75 days for bilateral lengthening temporalis myoplasty and 2.8 for unilateral lengthening temporalis myoplasty). Nine patients required minor revisions. Lengthening temporalis myoplasty is a safe alternative to free tissue transfer for dynamic smile reconstruction in children with facial paralysis. Limited donor-site morbidity, shorter operative times, and shorter hospital stays are some benefits over free flap options. However, revisions are required frequently secondary to tendon avulsions and adhesions. Therapeutic, IV.

  7. [A study of laparoscopic stoma creation for patients with malignant bowel obstruction].

    PubMed

    Nakata, Ken; Fukunaga, Mutsumi; Ebihara, Takeshi; Kato, Fumitaka; Amano, Kouji; Babaya, Akihito; Matsushita, Ako; Furukawa, Haruna; Matsushima, Yuko; Matsumoto, Hironori; Fujihara, Shinichi; Kawabata, Ryohei; Usui, Akihiro; Yamamoto, Tameyoshi; Oda, Kazuyuki; Kawase, Tomono; Kimura, Yutaka; Nakata, Yasuki; Ohzato, Hiroki

    2013-11-01

    We evaluated the efficacy of laparoscopic palliative stoma creation for patients with malignant bowel obstruction (MBO). Twenty-four patients with MBO who underwent laparoscopic stoma creation between January 2009 and December 2012 were studied and their clinical outcome was evaluated retrospectively. Compared to the open approach, the laparoscopic approach led to significantly shorter operation times and a significantly lower incidence of surgical site infection( SSI). The rate of removal of the intestinal tube and intravenous drip after surgery was 100% and 88%, respectively, and the rate of oral intake was 100% after palliative stoma creation. The prognosis was 58% in 3 months and 29% in 1 year, and the median survival time was approximately 4 months. The quality of surgery by the laparoscopic approach was better than that by the open approach, and the quality of life( QOL) after stoma creation was better than that before surgery. Given the shorter operation time, lower incidence of SSI, and better QOL, laparoscopic stoma creation is a beneficial choice for palliative treatment in patients with MBO.

  8. Transoral robotic surgery vs transoral laser microsurgery for resection of supraglottic cancer: a pilot surgery.

    PubMed

    Ansarin, Mohssen; Zorzi, Stefano; Massaro, Maria Angela; Tagliabue, Marta; Proh, Michele; Giugliano, Gioacchino; Calabrese, Luca; Chiesa, Fausto

    2014-03-01

    Transoral laser microsurgery (TLM) is a mature approach to supraglottic cancer, while transoral robotic surgery (TORS) is emerging. The present study compared these approaches. The first 10 patients (2002-2005) given TLM were compared with the first 10 (2007-2011) given TORS for cT1-3 cN0-cN2c supraglottic cancer. A feeding tube was used in four TLM and seven TORS patients. Margins were more often positive, but operating times shorter, in TORS. All 10 TORS patients are without evidence of disease, but only six TLM patients remain disease-free after much longer follow-up. TORS was considerably less uncomfortable and fatiguing for the surgeon. TORS seems as safe and effective as TLM. Shorter TORS operating times are probably attributable to prior experience with TLM. For laryngeal exposure, length of tube placement and margin evaluability, TLM was superior; however, this may change as TORS develops and transoral robotic instruments are optimized. Copyright © 2013 John Wiley & Sons, Ltd.

  9. A comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulation by experienced operators.

    PubMed

    He, Yi-Zhou; Zhong, Ming; Wu, Wei; Song, Jie-Qiong; Zhu, Du-Ming

    2017-04-01

    The axillary vein is an easily accessible vessel that can be used for ultrasound-guided central vascular access and offers an alternative to the internal jugular and subclavian veins. The objective of this study was to identify which transducer orientation, longitudinal or transverse, is better for imaging the axillary vein with ultrasound. We analyzed 236 patients who had undergone central venous cannulation of axillary vein in this retrospective study. Patients were divided into two groups, the longitudinal approach group (n=120) and transverse approach group (n=116). Recorded the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate. We perform chest radiography to confirm pneumothorax on all patients. We compared the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate between the two groups. The two groups were comparable with clinical characters of patients. The overall success rates of the longitudinal group and the transverse group were both 100%. The rate of one-attempt success in the longitudinal approach group is higher than the transverse approach group (91.7% vs. 82.8%, P=0.040). The transverse approach group had shorter operation time than the longitudinal group (184.7±8.1 vs. 287.5±19.6 seconds, P=0.000). The two groups had lower postoperative complications. Arterial puncture occurred in 1 of 120 longitudinal and 2 of 116 transverse attempts and this difference was no significant (P=0.541). No pneumothorax occurred in the two groups. The longitudinal approach during ultrasound-guided axillary vein cannulation is associated with greater one-attempt success rate compared with the transverse approach by experienced operators. The transverse approach has shorter operation time. The two groups have lower postoperative complications and are comparable with pneumothorax and arterial puncture.

  10. Operative treatment of acute acromioclavicular dislocations Rockwood III and V-Comparative study between K-wires combined with FiberTape(®) vs. TightRope System(®).

    PubMed

    Vrgoč, G; Japjec, M; Jurina, P; Gulan, G; Janković, S; Šebečić, B; Starešinić, M

    2015-11-01

    Acromioclavicular (AC) joint dislocations usually occur in a young active population as a result of a fall on the shoulder. Rockwood divided these dislocations into six types. Optimal treatment is still a matter of discussion. Many operative techniques have been developed, but the main choice is between open and minimally-invasive arthroscopic procedures. The aim of this study was to compare two different surgical methods on two groups of patients to find out which method is superior in terms of benefit to the patient. The methods were evaluated through objective and subjective scores, with a focus on complications and material costs. A retrospective two-centre study was conducted in patients with acute AC joint dislocation Rockwood types III and V. The two methods conducted were an open procedure using K-wires combined with FiberTape(®) (Arthrex, Naples, USA) (Group 1) and an arthroscopic procedure using the TightRope System(®) (Arthrex, Naples, USA) (Group 2). Groups underwent procedures during a two-year period. Diagnosis was based on the clinical and radiographic examination of both AC joints. Surgical treatment and rehabilitation were performed. Sixteen patients were included in this study: Group 1 comprised 10 patients, all male, average age 41.6 years (range 17-64 years), Rockwood type III (eight patients) and Rockwood type V (two patients); Group 2 had six patients, one female and five male, average age 37.8 years (range 18-58 years), Rockwood type III (two patients) and Rockwood type V (four patients). Time from injury to surgery was shorter and patients needed less time to return to daily activities in Group 1. Duration of the surgical procedure was shorter in Group 2 compared with Group 1. Complications of each method were noted. According to the measured scores and operative outcome between dislocation Rockwood type III and V, no significant difference was found. Implant material used in Group 2 was 4.7 times more expensive than that used in Group 1. Both methods offer many advantages with satisfying evaluated scores. K-wires with FiberTape(®) offer a shorter period for complete recovery and a significantly more cost-effective outcome, whereas the TightRope System(®) offers shorter operative procedure, better cosmetic result and avoidance of intraoperative fluoroscopy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Comparison of Both Sides for Retroperitoneal Laparoscopic Donor Nephrectomy: Experience From a Single Center in China.

    PubMed

    Qiu, Y; Wang, X; Song, T; Rao, Z; Liu, J; Huang, Z; Lin, T

    Laparoscopic donor nephrectomy (LDN) has gradually become the main approach to obtain live donor kidneys. However, the shorter right renal vein limits its wider application. The aim of this study was to compare the outcomes of left- and right-side retroperitoneal LDN. We reviewed the perioperative data of 527 consecutive donors receiving retroperitoneal pure LDN with a new method at our center between April 2009 and April 2014. The patients were divided into group A (the first 100 patients) and group B (the remaining 427 patients). A total of 423 cases of left donor surgery and 104 cases of right donor surgery were compared. The comparison of the laterality of LDN was also performed between group A and group B. This is currently the largest case series of LDN in our country. Although right-side LDN patients had longer operation time and a slightly higher incidence of intraoperative complications compared with left-side LDN patients, the operation time was shorter in both the groups compared with previous reports. In group B, patients undergoing right-side LDN had longer operation time and more frequent complications. Once the learning curve of 100 cases was completed, the incidence of complications and operation time were greatly reduced in both sides for LDN. There was no significant difference in the serum creatinine levels in recipients at 6 months of follow-up. Despite a slightly higher incidence of complications and longer operation time, right-side LDN can achieve equally safe and effective transplantation outcomes. This expands the source of potential donor kidneys. Copyright © 2017. Published by Elsevier Inc.

  12. Submental island pedicled flap vs radial forearm free flap for oral reconstruction: comparison of outcomes.

    PubMed

    Paydarfar, Joseph A; Patel, Urjeet A

    2011-01-01

    To compare intraoperative, postoperative, and functional results of submental island pedicled flap (SIPF) against radial forearm free flap (RFFF) reconstruction for tongue and floor-of-mouth reconstruction. Multi-institutional retrospective review. Academic tertiary referral center. Consecutive patients from February 2003 to December 2009 undergoing resection of oral tongue or floor of mouth followed by reconstruction with SIPF or RFFF. Two groups: SIPF vs RFFF. Duration of operation, hospital stay, surgical complications, and speech and swallowing function. The study included 60 patients, 27 with SIPF reconstruction and 33 with RFFF reconstruction. Sex, age, and TNM stage were similar for both groups. Mean flap size was smaller for SIPF (36 cm²) than for RFFF (50 cm²) (P < .001). Patients undergoing SIPF reconstruction had shorter operations (mean, 8 hours 44 minutes vs 13 hours 00 minutes; P < .001) and shorter hospitalization (mean, 10.6 days vs 14.0 days; P < .008) compared with patients who underwent RFFF. Donor site, flap-related, and other surgical complications were comparable between groups, as was speech and swallowing function. Reconstruction of oral cavity defects with the SIPF results in shorter operative time and hospitalization without compromising functional outcomes. The SIPF may be a preferable option in reconstruction of oral cavity defects less than 40 cm².

  13. Midface distraction osteogenesis: internal vs. external devices.

    PubMed

    Meling, T R; Høgevold, H-E; Due-Tønnessen, B J; Skjelbred, P

    2011-02-01

    This study compares internal and external distraction devices in the treatment of midface retrusion. 20 patients were treated with midface distraction (12 Crouzon, 4 Apert, 4 others); 12 with internal distraction (MID device), 8 with external distraction (Red or Blue device). The two groups were compared regarding operation time, peroperative blood loss and complications. The groups were comparable regarding patient age, sex, weight and diagnosis. In the MID-group, 7 of 12 patients (58%) underwent Le Fort III, 5 underwent 12 monobloc (32%). In the Blue device group, three of eight patients underwent Le Fort II (38%), three of eight underwent Le Fort III (38%), and two of eight underwent monobloc (25%). Operation time was shorter in the Blue device (mean 298 min) than in the MID group (mean 354 min). Peroperative blood loss and complication rates were similar. The internal distraction device is the 'gold standard' for treating midface retrusion. The use of an external distraction device in midface distraction osteogenesis is associated with a shorter operation time; peroperative blood loss and complications were similar. An external device affords better 3-dimensional control during the distraction process, so external distraction is preferable in patients who will tolerate this treatment. Copyright © 2010 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. [The randomized controlled trial of influences of T shape approach on the function of knee joint in the treatment of proximal tibial fractures].

    PubMed

    Peng, Wei-xiong; Zhang, Zhi; Liang, Jie-hong

    2008-04-01

    To investigate the clinical value of T shape approach in the treatment of proximal tibial fractures. One handrend and thirteen patients of proximal tibial fractures were randomly divided into two groups. Group A: 62 cases underwent the traditional exposure approach. According to Schatzker classification,the cases of II to VI type was 25, 10, 16, 6, 5 respectively. Group B:51 cases underwent T shape approach ahead of knee joint, the cases of II to VI type was 21, 8, 13, 5, 4 respectively. All data were analyzed by SPSS 10.0 to compare operation time, blood loss, duration of hospitalization, healing time, the time of osseous union and complications after operation. Sixty patients in group A and 50 patients in group B were followed-up from 12 to 24 months. (1) Operation time:group B was longer than A (P < 0.01). (2) Mean blood loss and duration of hospitalization was the same. (3) Clinical healing time:group B was shorter. (4) Mean time of osseous union: 48 group B was shorter. Function of knee: group B was better than group A. (Complication: group B was less than group A. As compared with traditional exposure approach, T shape approach of knee joint had advantages of small scar, fewer complications, faster union of fracture and earlier recovery of joint function. The approach is valuable for the treatment of proximal tibial fractures.

  15. Specific Resistance. Operational Control Tests for Wastewater Facilities. Instructor's Manual [and] Student Workbook.

    ERIC Educational Resources Information Center

    Wooley, John F.

    A commonly used test for determining filterability of conditioned sludge is the specific resistance (Buchner funnel) test. The sludge is filtered through filter paper using a Buchner funnel, and the time needed to obtain a given volume of filtrate (or for cake residue to begin to crack) is measured. The shorter the time, the better the…

  16. Two-micron (Thulium) Laser Prostatectomy: An Effective Method for BPH Treatment.

    PubMed

    Jiang, Qi; Xia, Shujie

    2014-01-01

    The two-micron (thulium) laser is the newest laser technique for treatment of bladder outlet obstruction resulting from benign prostatic hyperplasia (BPH). It takes less operative time than standard techniques, provides clear vision and lower blood loss as well as shorter catheterization times and hospitalization times. It has been identified to be a safe and efficient method for BPH treatment regardless of the prostate size.

  17. Robot-assisted approach improves surgical outcomes in obese patients undergoing partial nephrectomy.

    PubMed

    Malkoc, Ercan; Maurice, Matthew J; Kara, Onder; Ramirez, Daniel; Nelson, Ryan J; Caputo, Peter A; Mouracade, Pascal; Stein, Robert; Kaouk, Jihad H

    2017-02-01

    To assess the impact of approach on surgical outcomes in otherwise healthy obese patients undergoing partial nephrectomy for small renal masses. Using our institutional partial nephrectomy database, we abstracted data on otherwise healthy (Charlson comorbidity score ≤1 and bilateral kidneys), obese patients (body mass index >30 kg/m 2 ) with small renal masses (<4 cm) treated between 2011 and 2015. The primary outcomes were intra-operative transfusion, operating time, length of hospital stay (LOS), and postoperative complications. The association between approach, open (OPN) vs robot-assisted partial nephrectomy (RAPN), and outcomes was assessed by univariable and multivariable logistic regression analyses. Covariates included age, gender, obesity severity, tumour size and tumour complexity. Of 237 obese patients undergoing partial nephrectomy, 25% underwent OPN and 75% underwent RAPN. Apart from larger tumour size in the OPN group (2.8 vs 2.5 cm; P = 0.02), there was no significant difference between groups. The rate of intra-operative blood transfusion (1.1 vs 10%; P = 0.01), the median operating time (180 vs 207 min; P < 0.01) and the median ischaemia time (19.5 vs 27 min; P < 0.01) were all greater for OPN. The LOS was significantly shorter for RAPN (3 vs 4 days; P < 0.01). While the overall complication rate was higher for OPN (15.8 vs 31.7%; P < 0.01), major complications were not significantly different (5.6 vs 1.7%; P = 0.20). On multivariable analyses, OPN independently predicted longer operating time, longer length of stay, and more overall complications. At a high-volume centre, the robot-assisted approach offers less blood transfusion, shorter operating time, faster recovery, and fewer peri-operative complications compared with the open approach in obese patients undergoing partial nephrectomy for small renal masses. In this setting, RAPN may be a preferable treatment option. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  18. Comparing the Efficiencies of Third Molar Surgeries With and Without a Dentist Anesthesiologist

    PubMed Central

    Young, S.; Boukas, E.; Davidian, E.; Carnahan, J.

    2017-01-01

    Two different anesthesia models were compared in terms of surgical duration, safer outcomes, and economic implications. Third molar surgeries performed with and without a separate dentist anesthesiologist were evaluated by a retrospective data analysis of the surgical operative times. For more difficult surgeries, substantially shorter operative times were observed with the dentist anesthesiologist model, leading to a more favorable surgical outcome. An example calculation is presented to demonstrate economic advantages of scheduling the participation of a dentist anesthesiologist for more difficult surgeries. PMID:28128661

  19. The surgical outcomes of robot-assisted laparoscopic pancreaticoduodenectomy versus laparoscopic pancreaticoduodenectomy for periampullary neoplasms: a comparative study of a single center.

    PubMed

    Liu, Rong; Zhang, Tao; Zhao, Zhi-Ming; Tan, Xiang-Long; Zhao, Guo-Dong; Zhang, Xuan; Xu, Yong

    2017-06-01

    Pancreaticoduodenectomy (PD) is a difficult and complex operation. The introduction of robotics has opened up new angles in pancreatic surgery. This study aims to assess the surgical outcomes of robot-assisted laparoscopic pancreaticoduodenectomy relative to its laparoscopic counterpart. A retrospective study was designed to compare the surgical outcomes of 27 robot-assisted laparoscopic pancreaticoduodenectomy (RPD) and 25 laparoscopic pancreaticoduodenectomy (LPD). Perioperative data, including operating time, complication, morbidity and mortality, estimated blood loss, and postoperative length of stay, were analyzed. The robotic group exhibited significantly shorter operative time (mean 387 vs. 442 min), shorter hospital stay (mean 17 vs. 24 days), and less blood loss (mean 219 vs. 334 ml) than those in the LPD group. No statistical difference was observed between the two groups in terms of complication rate, mortality rate, R0 resection rate, and number of harvested lymph node. RPD is more efficient and secure process than LPD among properly selected patients. RPD is therefore a feasible alternative to the laparoscopic procedure. Further studies are needed to evaluate the cost effectiveness of the robotic approach for PD.

  20. Comparison of clinical outcomes of iris fixation and scleral fixation as treatment for intraocular lens dislocation.

    PubMed

    Kim, Kyeong Hwan; Kim, Wan Soo

    2015-09-01

    To compare the efficacy and safety of iris fixation with scleral fixation in surgical repositioning of dislocated intraocular lenses (IOLs). Retrospective, consecutive, comparative interventional case series. setting: Referral hospital. Seventy-eight consecutive patients who underwent surgical repositioning of dislocated intraocular lenses using suturing to the sclera or iris. Forty-four eyes of 44 patients underwent scleral fixation and 35 eyes of 34 patients underwent iris fixation of dislocated intraocular lenses. Visual acuity, refractive stability, operation time, and perioperative complications, including recurrence of IOL dislocation. Corrected distance visual acuity (CDVA) improved significantly 1 month postoperatively in both groups (P < .01 each), and remained stable for 12 months. One week postoperatively, however, CDVA improved significantly in the scleral fixation (P = .040) but not in the iris fixation (P = .058) group. The amount of refractive error significantly diminished 1 day after surgery (P = .028 in the scleral fixation and P = .046 in the iris fixation group). For the astigmatic components, Jackson crossed cylinders equivalent to conventional cylinders of positive power at axes of 0 degrees (J0) and 45 degrees (J45), J45 differed significantly in the scleral fixation and iris fixation groups (P = .009), whereas J0 was similar (P > .05). Operation time was significantly shorter (P = .0007), while immediate postoperative inflammation was significantly more severe (P = .001), in the iris fixation than in the scleral fixation group. Recurrence rates were similar (P > .05), but the mean time to recurrence was significantly shorter in the iris fixation than in the scleral fixation group (P = .031). Iris fixation and scleral fixation techniques had similar efficacy in the repositioning of dislocated intraocular lenses. Although operation time was shorter for iris fixation, it had several disadvantages, including induced astigmatism, immediate postoperative inflammation, earlier recurrence, and less stable refraction. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Soleus muscle H-reflex monitoring in endoscopic surgery under general anesthesia percutaneous interlaminar approach.

    PubMed

    Wang, Huixue; Gao, Yingji; Ji, Lixin; Bai, Wanshan

    2018-05-01

    The clinical value of soleus muscle H-reflex monitoring in general anesthesia percutaneous interlaminar approach was investigated. A total of 80 cases with unilateral L5-S1 disc herniation between January 2015 and October 2016 were randomly divided into control group (without soleus muscle H-reflex monitoring, n=40) and observation group (with soleus muscle H-reflex monitoring, n=40). Results showed that the operation time of the observation group was shorter than that of the control group (P<0.05), and the blood loss during the operation was less than that of the control group (P<0.05). The length of postoperative hospital stay was shorter than that of the control group (P<0.05). At 24 h after operation, the amplitude of H-reflex in diseased side soleus muscle was significantly lower than that in healthy side (P<0.05). The preoperative, postoperative and 24 h postoperatively, the latency of H-reflex in diseased side soleus muscle was shorter than that of healthy side (P<0.05). The latency and amplitude of H-reflex latency in soleus muscle were significantly lower (P<0.05), and the height of intervertebral space in observation group was significantly higher than that in control group (P<0.05). The total percentage of postsurgical sensory dysfunction, dyskinesia, post-root canal stenosis, disc herniation and cerebrospinal fluid leakage was lower than that of the control group (P<0.05). Japanese Orthopaedic Association score of the observation group was significantly higher at 1 month, and 1 year after operation lower than the control group (P<0.05). Taken together, soleus muscle H-reflex monitoring can effectively reduce the damage to the nerve roots under percutaneous endoscopic intervertebral endoscopic surgery under general anesthesia, improve the accuracy of surgery, reduce the complications, shorten the operation time and reduce the surgical bleeding, which is more beneficial to patients smooth recovery.

  2. Comparison of intra-operative specimen mammography to standard specimen mammography for excision of non-palpable breast lesions: a randomized trial.

    PubMed

    Miller, Cynthia L; Coopey, Suzanne B; Rafferty, Elizabeth; Gadd, Michele; Smith, Barbara L; Specht, Michelle C

    2016-02-01

    Standard specimen mammography (SSM) is performed in the radiology department after wire-localized excision of non-palpable breast lesions to confirm the presence of the target and evaluate margins. Alternatively, intra-operative specimen mammography (ISM) allows surgeons to view images in the operating room (OR). We conducted a randomized study comparing ISM and SSM. Women undergoing wire-localized excision for breast malignancy or imaging abnormality were randomized to SSM or ISM. For SSM, the specimen was transported to the radiology department for imaging and interpretation. For ISM, the specimen was imaged in the OR for interpretation by the surgeon and sent for SSM. Interpretation time was from specimen leaving OR until radiologist interpretation for SSM and from placement in ISM device until surgeon interpretation for ISM. Procedure and interpretation times were compared. Concordance between ISM and SSM for target and margins was evaluated. 72 patients were randomized, 36 ISM and 36 SSM. Median procedure times were similar, 48.5 (17-138) min for ISM, and 54 (17-40) min for SSM (p = 0.72), likely since specimens in both groups traveled to radiology for SSM. Median interpretation time was significantly shorter with ISM, 1 (0.5-2.0) and 9 (4-16) min for ISM and SSM, respectively (p < 0.0001). Among specimens with ISM and SSM, concordance was 100 % (35/35) for target and 93 % (14/15) for margins. In this randomized trial, use of ISM compared with SSM significantly reduced interpretation times, while accurately identifying the target. This could result in decreased operative costs from shorter OR times with use of ISM.

  3. Prospective Comparative Study of the Efficacy and Safety of New-Generation Versus First-Generation System for Super-Mini-Percutaneous Nephrolithotomy: A Revolutionary Approach to Improve Endoscopic Vision and Stone Removal.

    PubMed

    Zeng, Guohua; Zhu, Wei; Liu, Yang; Fan, Junhong; Lam, Wayne; Lan, Yu; Cai, Chao; Deng, Tuo; Li, Xiaohang; Zhao, Zhijian

    2017-11-01

    The study sought to compare the procedural and clinical results of super-mini-percutaneous nephrolithotomy (SMP) with the use of first- and new-generation devices. A prospective, comparative cohort study was carried out between February 2013 and January 2017. Patients who underwent either first- or new-generation SMP were eligible for the study. Inclusion criteria were adult patients with renal stone <4 cm, or in pediatric patients with renal stone <2.5 cm with a history of failed extracorporeal shockwave lithotripsy. The primary outcome of the present study was the operating time, which was calculated from the starting of percutaneous puncture to the wound closure. Secondary outcomes were the stone-free rate (SFR), blood loss (hemoglobin decrease), hospital stay, and postoperative complications. One hundred fifty-six consecutive patients who underwent SMP for treatment of renal stones were eligible for the study, with the first 85 patients undergoing SMP with the first-generation device, and the remaining 71 consecutive patients being treated with the new-generation SMP system. The two groups of patients had comparable demographic data, including age, BMI, stone size, Guy's score, stone location, comorbidities, grade of hydronephrosis, and history of urinary tract infection. The new-generation SMP had a shorter operation time (39.3 vs 50.5 min, p = 0.016) and shorter postoperative hospitalization time (2.1 vs 3.0 days, p < 0.001) than the first-generation SMP. No significant difference existed between the two groups for SFR, hemoglobin decrease, and tubeless rate. The overall operative complication rates using the Clavien-Dindo grading system were similar between the two cohorts of patients. The clinical outcomes of the new-generation SMP in patients with moderate-sized renal stone were comparable when compared with the first-generation SMP. New-generation SMP system using an irrigation/suction sheath improved intraoperative irrigation, a more efficient hydrodynamic mechanism for retrieval of fragments. This may account for the shorter operative time than the first-generation SMP system demonstrated in this study.

  4. Treatment of gallbladder stone with common bile duct stones in the laparoscopic era.

    PubMed

    Zhang, Wei-jie; Xu, Gui-fang; Huang, Qin; Luo, Kun-lun; Dong, Zhi-tao; Li, Jie-ming; Wu, Guo-zhong; Guan, Wen-xian

    2015-01-26

    Laparoscopic common bile duct exploration (LCBDE) for stone can be carried out by either laparoscopic transcystic stone extraction (LTSE) or laparoscopic choledochotomy (LC). It remains unknown as to which approach is optimal for management of gallbladder stone with common bile duct stones (CBDS) in Chinese patients. From May 2000 to February 2009, we prospective treated 346 consecutive patients with gallbladder stones and CBDS with laparoscopic cholecystectomy and LCBDE. Intraoperative findings, postoperative complications, postoperative hospital stay and costs were analyzed. Because of LCBDE failure,16 cases (4.6%) required open surgery. Of 330 successful LCBDE-treated patients, 237 underwent LTSE and 93 required LC. No mortality occurred in either group. The bile duct stone clearance rate was similar in both groups. Patients in the LTSE group were significantly younger and had fewer complications with smaller, fewer stones, shorter operative time and postoperative hospital stays, and lower costs, compared to those in the LC group. Compared with patients with T-tube insertion, patients in the LC group with primary closure had shorter operative time, shorter postoperative hospital stay, and lower costs. In cases requiring LCBDE, LTSE should be the first choice, whereas LC may be restricted to large, multiple stones. LC with primary closure without external drainage of the CBDS is as effective and safe as the T-tube insertion approach.

  5. Potential Benefits of Rib Fracture Fixation in Patients with Flail Chest and Multiple Non-flail Rib Fractures.

    PubMed

    Qiu, Meiguang; Shi, Zhanjun; Xiao, Jun; Zhang, Xuming; Ling, Shishui; Ling, Hao

    2016-12-01

    The purpose of this study is to evaluate the potential benefits of rib fracture fixation in patients with flail chest and multiple non-flail rib fractures versus conventional treatment modalities. A retrospective reviewed study compared 86 cases which received surgical treatment between June 2009 and May 2013 to 76 cases which received conservative treatment between January 2006 and May 2009. The patients were divided into the flail chest ( n  = 38) and multiple non-flail rib fracture groups ( n  = 124). In the flail chest group, the mechanical ventilation time, ICU monitoring time, tracheostomies, thoracic deformity, and impaired pulmonary function and return to full-time employment were compared. In the multiple non-flail rib fracture group, fracture healing, visual analog scale (VAS) pain score, inpatient length of stay, atelectatic, pulmonary complications, and normal activity-returning time were compared. Patients in the flail chest operative fixation group had significantly shorter ICU stay, decreased ventilator requirements, fewer tracheostomies, less thoracic deformity and impaired pulmonary function, and more returned to full-time employment. Patients in the multiple non-flail rib fracture operative fixation had shorter hospital stay, less pain, earlier return to normal activity, more fracture healing, less atelectasis, and fewer pulmonary infections. This study demonstrates the potential benefits of surgical stabilization of flail chest and multiple non-flail rib fractures with plate fixation. When compared with conventional conservative management, operatively managed patients demonstrated improved clinical outcomes.

  6. Comparison between submucosal tunneling endoscopic resection and video-assisted thoracoscopic surgery for large esophageal leiomyoma originating from the muscularis propria layer.

    PubMed

    Tan, Yuyong; Lv, Liang; Duan, Tianying; Zhou, Junfeng; Peng, Dongzi; Tang, Yao; Liu, Deliang

    2016-07-01

    Submucosal tunneling endoscopic resection (STER) has been proved to be safe and effective for removal of esophageal leiomyoma originating from the muscularis propria (MP) layer. However, there are still technical challenges for tumors ≥35 mm due to the limited space of the submucosal tunnel. The aim of the study was to estimate the safety and efficacy of STER for large esophageal leiomyoma originating from the MP layer as well as compare its efficacy with video-assisted thoracoscopic surgery (VATS), which is a standard procedure for treating esophageal leiomyoma. We retrospectively collected the clinical data of the patients with esophageal leiomyoma of 35-55 mm who underwent STER or VATS at our hospital between January 2010 and December 2014. Epidemiological data (gender, age), tumor location, tumor size, procedure-related parameters, complications, length of stay and cost were compared between STER and VATS. A total of 31 patients were enrolled, and 18 patients underwent STER and the other 13 received VATS. There was no significant difference between the two groups in gender, age, tumor location, tumor size, complications and rate of en bloc resection (P > 0.05). However, patients in the STER groups had a shorter operation time, a less decrease in hemoglobin level, a shorter length of hospital stay and a decreased cost (P < 0.05). No recurrence was noted in the STER and VATS groups during a mean follow-up of 10.9 and 30.8 months, respectively. The treatment efficacy was comparable between the STER and VATS for esophageal leiomyoma of 35-55 mm. However, STER is superior to VATS in a shorter operation time, a less decrease in hemoglobin level, a shorter length of hospital stay and a decreased cost.

  7. The new economics of radical prostatectomy: cost comparison of open, laparoscopic and robot assisted techniques.

    PubMed

    Lotan, Yair; Cadeddu, Jeffrey A; Gettman, Matthew T

    2004-10-01

    We evaluated the costs components of laparoscopic (LRP) and robot assisted prostatectomy (RAP), and compared their costs to those of open radical retropubic prostatectomy (RRP). A model was created using commercially available software to compare the costs of treatment with LRP, RAP or RRP. Hospital costs were obtained from a large county hospital. A literature search was performed to determine typical (average) robot costs, length of stay and operative time for RRP, LRP and RAP. We limited our analysis to mature series and included only the most recent efforts. The cost of the robot was estimated at 1,200,000 dollars with a 100,000 dollars yearly maintenance contract. It was assumed that the robot would be used across specialities for a total of 300 cases yearly in a 7-year period. We performed a series of 1 and 2-way sensitivity analyses to evaluate the costs of LRP, RAP and RRP, while varying robot costs, the number of robotic cases, hospital length of stay, operative time and cost of laparoscopic/robotic equipment. RRP was the most cost-effective approach with a cost advantage of 487 dollars and 1,726 dollars over LRP and RAP, respectively. If we excluded the initial cost of purchasing a robot, the cost difference between RRP and RAP was 1,155 dollars. This large difference in RRP and RAP costs resulted from a cost of 857 dollars per case to pay for robot purchase and maintenance, and the high cost of 1,705 dollars for equipment per case. An even shorter RAP operative time (140 vs 160 minutes) and length of stay (1.2 vs 2.5 days) did not compensate for the added expenditure. LRP cost more than RRP primarily due to equipment costs (533 dollars) since the shorter hospital stay (1.3 vs 2.5 days) was compensated for by longer operative time (200 vs 160 minutes). The costs of new technology are typically borne out in the first years of use and RAP is no exception with high robot costs for purchase, maintenance and operative equipment overshadowing savings gained by shorter length of stay. While RRP is currently the least costly approach, LRP has proved to be almost as cost competitive as RRP, whereas RAP will require a significant decrease in the cost of the device and maintenance fees.

  8. Endoscopic stenting versus operative gastrojejunostomy for malignant gastric outlet obstruction.

    PubMed

    Chandrasegaram, Manju D; Eslick, Guy D; Mansfield, Clare O; Liem, Han; Richardson, Mark; Ahmed, Sulman; Cox, Michael R

    2012-02-01

    Malignant gastric outlet obstruction represents a terminal stage in pancreatic cancer. Between 5% and 25% of patients with pancreatic cancer ultimately experience malignant gastric outlet obstruction. The aim in palliating patients with malignant gastric outlet obstruction is to reestablish an oral intake by restoring gastrointestinal continuity. This ultimately improves their quality of life in the advanced stages of cancer. The main drawback to operative bypass is the high incidence of delayed gastric emptying, particularly in this group of patients with symptomatic obstruction. This study aimed to compare surgical gastrojejunostomy and endoscopic stenting in palliation of malignant gastric outlet obstruction, acknowledging the diversity and heterogeneity of patients with this presentation. This retrospective study investigated patients treated for malignant gastric outlet obstruction from December 1998 to November 2008 at Nepean Hospital, Sydney, Australia. Endoscopic duodenal stenting was performed under fluoroscopic guidance for placement of the stent. The operative patients underwent open surgical gastrojejunostomy. The outcomes assessed included time to diet, hospital length of stay (LOS), biliary drainage procedures, morbidity, and mortality. Of the 45 participants in this study, 26 underwent duodenal stenting and 19 had operative bypass. Comparing the stenting and operative patients, the median time to fluid intake was respectively 0 vs. 7 days (P < 0.001), and the time to intake of solids was 2 vs. 9 days (P = 0.004). The median total LOS was shorter in the stenting group (11 vs. 25 days; P < 0.001), as was the median postprocedure LOS (5 vs. 10 days; P = 0.07). Endoscopic stenting is preferable to operative gastrojejunostomy in terms of shorter LOS, faster return to fluids and solids, and reduced morbidity and in-hospital mortality for patients with a limited life span.

  9. Utility of Intravascular US-Guided Portal Vein Access during Transjugular Intrahepatic Portosystemic Shunt Creation: Retrospective Comparison with Conventional Technique in 109 Patients.

    PubMed

    Pillai, Anil K; Andring, Brice; Faulconer, Nicholas; Reis, Stephen P; Xi, Yin; Iyamu, Ikponmwosa; Suthpin, Patrick D; Kalva, Sanjeeva P

    2016-08-01

    To compare safety and effectiveness of intravascular ultrasound (US)-guided portal vein access during transjugular intrahepatic portosystemic shunt (TIPS) creation with conventional TIPS technique. In this retrospective study, TIPS creation using intravascular US guidance in 55 patients was compared with conventional TIPS creation in 54 patients by 10 operators over a 3-year period. Operators were classified as experienced if they had performed ≥ 20 TIPS procedures at the beginning of the study period. Time to portal vein access, total radiation dose, and needle pass-related capsular perforation were recorded. Baseline demographic characteristics of patients were similar (P > .05). Mean time to portal venous access was 46 minutes ± 37 for conventional TIPS and 31 minutes ± 19 for intravascular US-guided TIPS (P = .007). Intravascular US guidance allowed significantly shorter times (48 min ± 30 vs 28 min ± 16; P = .01) to portal vein access among operators (n = 5) with limited experience but failed to achieve any significant time savings (44 min ± 43 vs 34 min ± 22; P = .89) among experienced operators (n = 5). Needle pass-related capsular perforation occurred in 17/54 (34%) patients with conventional TIPS and 5/55 (9%) patients with intravascular US-guided TIPS (P = .004). Radiation dose was 2,376 mGy ± 1,816 for conventional TIPS and 1,592 mGy ± 1,263 for intravascular US-guided TIPS (P = .004). Intravascular US-guided portal vein access during TIPS creation is associated with shorter portal vein access times, decreased needle pass-related capsular perforations, and reduced radiation dose. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  10. Hemi-transseptal Approach for Pituitary Surgery: A Follow-Up Study

    PubMed Central

    Fnais, Naif; Maio, Salvatore Di; Edionwe, Susan; Zeitouni, Anthony; Sirhan, Denis; Valdes, Constanza J.; Tewfik, Marc A.

    2016-01-01

    Objectives The hemi-transseptal (Hemi-T) approach was developed to overcome the potential drawbacks of the nasoseptal flap (NSF) in endoscopic endonasal transsphenoidal skull base surgery. In this study, we describe further refinements on the Hemi-T approach, and report long-term outcomes as compared with traditional methods of skull base reconstruction. Design A retrospective case-control study. Setting Montreal Neurological Institute and Jewish General Hospital, Montreal, Canada. Participants Patients who underwent endoscopic endonasal transsphenoidal approach to skull base pathology. Main Outcome Measures Operative time, CSF rhinorrhea, and postoperative nasal morbidity. Results A total of 105 patients underwent the Hemi-T approach versus 40 controls. Operative time was shorter using the Hemi-T technique (180.51 ± 56.9 vs. 202.9 ± 62 minutes; p = 0.048). The rates of nasal morbidity (septal perforation [5/102 vs. 6/37; p = 0.029] and mucosal adhesion [11/102 vs. 10/39 p = 0.027]), fascia lata harvest (21/100 vs. 18/39; p = 0.0028), and postoperative CSF leak rates (7/100 vs. 9/38; p = 0.006) were lower in the Hemi-T group. Conclusion Advantages of the Hemi-T approach over traditional exposure techniques include preservation of the nasal vascular pedicle, shorter operative time, reduced fascia lata harvest rates, and decreased nasal morbidity. PMID:28321378

  11. The use of LigaSure in patients with hyperthyroidism.

    PubMed

    Barbaros, Umut; Erbil, Yeşim; Bozbora, Alp; Deveci, Uğur; Aksakal, Nihat; Dinççağ, Ahmet; Ozarmağan, Selçuk

    2006-11-01

    Thyroidectomies of hyperthyroidic patients are known to be more blood-spattered than the operations performed for euthyroid nodular diseases and require careful hemostasis. Our purpose was to evaluate the efficacy of the use of LigaSure in patients with hyperthyroidism. Between January 2004 and October 2005, 100 patients underwent total or near-total thyroidectomy. Bipolar vessel ligation system (LigaSure) was the choice of modality for hemostasis in half of these patients, and the conventional suture ligation technique was used for the rest. The following data were evaluated non-randomized and prospectively in this study: patients demographics, thyroid pathology, operative duration, presence of complications, and the duration of the hospital stay. Comparisons of the data were evaluated by the Wilcoxon and chi-square tests. Among the patients of the LigaSure group, 14 patients were detected to have hyperthyroidism (seven patients with Graves' disease and another seven patients with multinodular toxic goiter), while 36 patients were found to be euthyroidic. The durations of the operation time and of the hospital stay of the patients in the LigaSure group were significantly lower than the conventional thyroidectomy group (p<0.05). The complication rates of the LigaSure and conventional thyroidectomy groups were 4 and 6%, respectively (p>0.05). The use of LigaSure as an operative technique in the treatment of Graves' disease and toxic goiter is a safe and effective modality that provides a shorter hospital stay and a shorter operation time as well.

  12. [The "gentle caesarean section" - an alternative to the classical way of sectio. A prospective comparison between the classical technique and the method of Misgav Ladach].

    PubMed

    Redlich, A; Köppe, I

    2001-11-01

    A new technical variant of caesarean section was described a few years ago, which is characterised by blunt surgical preparation and simplified seam technique. A prospective investigation compared the differences in the surgery and postoperative process as well as the rate of complications between this Misgav Ladach method and the conventional technique of Sectio. The individual postoperative well-being of the women was recorded by visual analog scales. - Women, whom realize the including criterias (first caesarean section, >/= 32. week of pregnancy, one baby), were examined in this study over one year: 105 patients operated with the Misgav Ladach method and 67 conventionally operated patients. The patients were randomized in a function of the first letter of the surname (A-K: Misgav-Ladach method; L-Z: classical technique). - The surgical time from the cut to the seam was significantly shorter (29.8 vs. 49.3 min; p < 0,001) in the Misgav Ladach group. There were no differences between the two methods in the rate of postoperative complications. The febrile morbidity was equivalent in both groups (7.6 % vs. 9 %), likewise the frequency of postoperative hematomas (3.8 % vs. 3 %). The postoperative period with consumption of analgetics was significantly longer in the group of conventionally operated patients (1.9 d vs. 2.4 d; p < 0.01). The postoperative presentness was estimated significantly better (p < 0,.01) by the patients of the Misgav ladach group - probably caused by the significantly earlier mobilization (p < 0.05). - The surgical technique described by Misgav and Ladach allows a safe execution of the caesarean section and represents an alternative to the conventional method. The duration of operation (cut-seam-time) was significantly shorter. The technique of less traumatising of tissue caused a significantly earlier mobilisation and a significantly shorter requirement of analgetics. The women estimated her postoperative physical condition as better.

  13. Comparative study of the ''Misgav Ladach'' and traditional Pfannenstiel surgical techniques for cesarean section.

    PubMed

    Belci, D; Kos, M; Zoricić, D; Kuharić, L; Slivar, A; Begić-Razem, E; Grdinić, I

    2007-06-01

    The aim of this study was to evaluate the advantages of the Misgav Ladach surgical technique compared to traditional cesarean section. A prospective randomized trial of 111 women undergoing cesarean section was carried out in the Pula General Hospital. Forty-nine operations were performed using the Pfannenstiel method of cesarean section, 55 by the Misgav Ladach method and 7 by lower midline laparotomy. It was proved that the cases where the Misgav Ladach method was implemented, compared to the Pfannenstiel method, showed a significantly shorter delivery/extraction and operative time (P=0.0009), the incision pain on the second postoperative day was significantly lower (0.021), we recorded a quicker stand up and walking time (P=0.013), significantly fewer analgesic injections and a shorter duration of analgesia were required (P=0.0009) and the bowel function was restored to normal sooner (P=0.001). The Misgav Ladach method of cesarean section has advantages over the Pfannenstiel method in so far as it is significantly quicker to perform, with diminished postoperative pain and less use of postoperative analgesics. The recovery of physiologic function is faster. No differences were found in intraoperative bleeding, maternal morbidity, scar appearance, uterus postoperative involution and the assessment of the inflammation response to the operative technique.

  14. Clinical outcome of using gastric remnant or jejunum or colon conduit in surgery for esophageal carcinoma with previous gastrectomy.

    PubMed

    Jun, Wang; Wei, Wen; Weibing, Wu; Jing, Xu; Fuxi, Zhen; Xiaoxiang, Xi; Bihong, Lu; Tong, Zhou; Liang, Chen; Jinhua, Luo

    2017-05-01

    For esophageal carcinoma patients with early gastrectomy, individualized surgical plans-including selection of replacement conduit and operation route based on patient's new lesion and surgical history-can achieve the desired therapeutic effect and improve postoperative life quality. We investigated the outcomes at our institution. The clinical data of 42 esophageal carcinoma patients with early gastrectomy were analyzed retrospectively. Esophagectomy was performed combining replacement with remnant stomach in 16 patients, jejunum in 17, and colon in 9. Esophagectomy combining replacement with gastric remnant got advantages of shorter operation time and less bleeding over that of replacement with jejunum or colon. Gastric remnant group scored higher on the QLQ-C30 questionnaire than jejunum or colon group with respect to overall quality of life, physical function, and social relationships. In QLQ-OES18 questionnaire, the scores of appetite recovery and reflux mitigation were more favorable in remnant stomach group than those in jejunum or colon group. Survival analysis showed no significant difference in survival rate among the patients undergoing replacement with gastric remnant, jejunum, or colon. For esophageal carcinoma patients with early gastrectomy, esophagus-gastric remnant anastomosis possesses advantages of shorter operation time, less surgical trauma, and greater life quality after surgery. © 2017 Wiley Periodicals, Inc.

  15. Crew Factors in Flight Operations 7: Psychophysiological Responses to Overnight Cargo Operations

    NASA Technical Reports Server (NTRS)

    Gander, Philippa H.; Gregory, Kevin B.; Connell, Linda J.; Miller, Donna L.; Graeber, R. Curtis; Rosekind, Mark R.

    1996-01-01

    To document the psychophysiological effects of flying overnight cargo operations, 41 B-727 crew members (average age 38 yr) were monitored before, during, and after one of two typical 8-day trip patterns. During daytime layovers, the average sleep episode was 3 hr (41%) shorter than nighttime sleeps and was rated as lighter, less restorative, and poorer overall. Sleep was frequently split into several episodes and totaled 1.2 hr less per 24 hr than on pretrip days. Each trip pattern included a night off, which was an effective countermeasure against the accumulating sleep debt. The organization of sleep during daytime layovers reflected the interaction of duty timing with circadian physiology. The circadian temperature rhythm did not adapt completely to the inverted wake-rest schedule on duty days, being delayed by about 3 hr. Highest subjective fatigue and lowest activation occurred around the time of the temperature minimum. On duty days, reports of headaches increased by 400%, of congested nose by 200%, and of burning eyes by 900%. Crew members also reported eating more snacks. Compared with daytime short-haul air-transport operations, the overnight cargo trips included fewer duty and flight hours, and had longer layovers. Overnight cargo crews also averaged 5.4 yr younger than their daytime short-haul counterparts. On trips, both groups lost a comparable amount of sleep per 24 hr, but the overnight cargo crews had shorter individual sleep episodes and more broken sleep. These data clearly demonstrate that overnight cargo operations, like other night work, involve physiological disruption not found in comparable daytime operations.

  16. A comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulation by experienced operators

    PubMed Central

    He, Yi-Zhou; Zhong, Ming; Wu, Wei; Song, Jie-Qiong

    2017-01-01

    Background The axillary vein is an easily accessible vessel that can be used for ultrasound-guided central vascular access and offers an alternative to the internal jugular and subclavian veins. The objective of this study was to identify which transducer orientation, longitudinal or transverse, is better for imaging the axillary vein with ultrasound. Methods We analyzed 236 patients who had undergone central venous cannulation of axillary vein in this retrospective study. Patients were divided into two groups, the longitudinal approach group (n=120) and transverse approach group (n=116). Recorded the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate. We perform chest radiography to confirm pneumothorax on all patients. We compared the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate between the two groups. Results The two groups were comparable with clinical characters of patients. The overall success rates of the longitudinal group and the transverse group were both 100%. The rate of one-attempt success in the longitudinal approach group is higher than the transverse approach group (91.7% vs. 82.8%, P=0.040). The transverse approach group had shorter operation time than the longitudinal group (184.7±8.1 vs. 287.5±19.6 seconds, P=0.000). The two groups had lower postoperative complications. Arterial puncture occurred in 1 of 120 longitudinal and 2 of 116 transverse attempts and this difference was no significant (P=0.541). No pneumothorax occurred in the two groups. Conclusions The longitudinal approach during ultrasound-guided axillary vein cannulation is associated with greater one-attempt success rate compared with the transverse approach by experienced operators. The transverse approach has shorter operation time. The two groups have lower postoperative complications and are comparable with pneumothorax and arterial puncture. PMID:28523170

  17. Bipolar microdebrider may reduce intraoperative blood loss and operating time during nasal polyp surgery.

    PubMed

    Kumar, Nishant; Sindwani, Raj

    2012-08-01

    Bleeding during endoscopic sinus surgery (ESS) can interrupt the flow of the procedure and increase the risk of complications. Advances in microdebrider design now allow for bleeding to be controlled by bipolar energy during the suctioning and shaving of polyps. We conducted a retrospective study to examine the effects of this technology on blood loss and operating times during ESS for chronic rhinosinusitis with nasal polyps (CRS+P). Our patient population was made up of 80 patients who had undergone ESS for CRS+P by the same surgeon from January 2007 through May 2008. All surgeries were performed with either the PK diego bipolar microdebrider (Gyrus ACMI, ENT Division; Bartlett, Tenn.) or a standard microdebrider. There were 40 patients in each group. The PK group was made up of 23 males and 17 females, aged 14 to 66 years (mean: 43.1), and the control group included 21 males and 19 females, aged 17 to 71 years (mean: 43.1); there were no statistically significant differences between the two groups in terms of sex and age. In addition to demographic data, the charts were reviewed for comorbidities and operative variables; the latter included blood loss, operating room (OR) time, and complications. The preoperative treatment and anesthesia protocols were similar for all patients, and all patients demonstrated a similar disease burden on imaging (mean Harvard CT stage: 3.12 for the PK group and 3.15 for the controls; p > 0.05). We found that during ESS, the PK group experienced significantly less intraoperative blood loss than did the controls (means: 86.0 and 123.0 ml, respectively; p = 0.015). In addition, the PK device was associated with significantly shorter OR times (means: 88.9 and 101.4 min, respectively; p = 0.026). There were no complications in either group. We conclude that using a microdebrider with bipolar capabilities during ESS may offer the advantages of less blood loss and shorter operating times in patients with nasal polyps.

  18. Cost analysis of injection laryngoplasty performed under local anaesthesia versus general anaesthesia: an Australian perspective.

    PubMed

    Chandran, D; Woods, C M; Schar, M; Ma, N; Ooi, E H; Athanasiadis, T

    2018-02-01

    To conduct a cost analysis of injection laryngoplasty performed in the operating theatre under local anaesthesia and general anaesthesia. The retrospective study included patients who had undergone injection laryngoplasty as day cases between July 2013 and March 2016. Cost data were obtained, along with patient demographics, anaesthetic details, type of injectant, American Society of Anesthesiologists score, length of stay, total operating theatre time and surgeon procedure time. A total of 20 cases (general anaesthesia = 6, local anaesthesia = 14) were included in the cost analysis. The mean total cost under general anaesthesia (AU$2865.96 ± 756.29) was significantly higher than that under local anaesthesia (AU$1731.61 ± 290.29) (p < 0.001). The mean operating theatre time, surgeon procedure time and length of stay were all significantly lower under local anaesthesia compared to general anaesthesia. Time variables such as operating theatre time and length of stay were the most significant predictors of the total costs. Procedures performed under local anaesthesia in the operating theatre are associated with shorter operating theatre time and length of stay in the hospital, and provide significant cost savings. Further savings could be achieved if local anaesthesia procedures were performed in the office setting.

  19. Comparison of Free-Beam- and Fiber-Type CO2 Laser Delivery Systems in Stapes Surgery.

    PubMed

    Chang, Mun Young; Choi, Hyun Seok; Lee, Sang-Youp; Koo, Ja-Won

    2017-07-01

    A free-beam-type CO 2 laser, which use a micromanipulator mounted on a microscope as the delivery system, has the merit of not being affected by hand tremor at the time of shooting. However, this delivery system has several disadvantages, including a restricted operation range and a risk of incorrect focusing. A fiber-type CO 2 laser uses a hand-held delivery system and has the opposite merits and demerits. We compared the results of stapes surgery with free-beam and fiber type delivery systems. The study enrolled 36 patients who underwent stapedotomy with free-beam- (n=26) or fiber- (n=10) type CO 2 lasers. The air-bone (AB) gap closure, bone conduction (BC) change, and operating time were evaluated. The AB gap closure was calculated by subtracting the preoperative BC thresholds from the postoperative air conduction thresholds. The BC change was calculated by subtracting the postoperative BC thresholds from the preoperative BC thresholds. The mean operating time was significantly ( p =0.035) shorter in the fiber-type group (72.5±8.2 min) than in the free-beam-type group (80.5±11.4 min). The mean AB gap closure did not differ significantly ( p =0.297) between the free-beamand fiber-type groups (5.8±10.1 and 1.4±6.8 dB, respectively). The mean BC change did not differ significantly ( p =0.873) between the free-beam- and fiber-type groups (2.4±6.9 and 2.8±5.3 dB, respectively). The hearing outcomes did not differ significantly between the two groups. Operating times were significantly shorter using the fiber-type CO 2 laser, while hearing outcomes did not differ significantly between the two groups.

  20. One-year follow-up of tension-free vaginal tape (TVT) and trans-obturator suburethral tape from inside to outside (TVT-O) for surgical treatment of female stress urinary incontinence: a prospective randomised trial.

    PubMed

    Zullo, Marzio Angelo; Plotti, Francesco; Calcagno, Marco; Marullo, Elettra; Palaia, Innocenza; Bellati, Filippo; Basile, Stefano; Muzii, Ludovico; Angioli, Roberto; Panici, Pierluigi Benedetti

    2007-05-01

    To compare tension-free vaginal tape (TVT) and trans-obturator suburethral tape from inside to outside (TVT-O) for surgical treatment of stress urinary incontinence (SUI) for complications (primary end point) and success rate (secondary end point). Seventy-two consecutive patients, with a mean age of 53.2 yr (range: 38-69 yr) and affected by SUI, were included in this randomised controlled trial. After preoperative assessment, patients were randomly allocated to the TVT or TVT-O procedure. Operative time, perioperative complications, and hospital stay were prospectively recorded. Cure of SUI was defined as no leakage of urine during the stress test at urodynamic testing at the 12-mo evaluation. The Wilcoxon signed rank sum test, Mann-Whitney U test, McNemar test, and Fisher exact test were used to verify statistical significance, set at p<0.05. All patients were evaluable at the 12-mo follow-up. The characteristics of patients were well balanced between groups after randomisation. The mean operative time was significantly shorter in the TVT-O group. Perioperative complications were significantly more common after the retropubic approach (5% and 27% in TVT-O and TVT groups, respectively, p<0.04). The groups did not differ significantly in intraoperative blood loss, hospital stays, and time to return to normal activities. Sixty-five patients (90%) were successfully treated for SUI 12 mo after the operation (89% and 91% for TVT-O and TVT groups, respectively). Both techniques appear to be equally effective in the surgical treatment of SUI. However, TVT-O had a shorter operative time and lower overall perioperative complication rate.

  1. Sleep and alertness in North Sea helicopter operations.

    PubMed

    Simons, Ries; Wilschut, Ellen S; Valk, Pierre J L

    2011-07-01

    Dutch North Sea helicopter operations are characterized by multiple sector flights to offshore platforms under difficult environmental conditions. In the context of a Ministry of Transport program to improve safety levels of helicopter operations, we assessed effects of pre-duty sleep, pre-duty travel time, and workload factors on the alertness and vigilance of pilots. Data of 24 pilots comprising 224 duty days were analyzed. Pilots performed 10-min test sessions after wake up, pre-duty, halfway-duty, end-duty, and at bedtime during normal duty rosters. Test sessions included completion of a vigilance task, vigor and sleepiness ratings, and questions on sleep and operational characteristics. Pilots wore an actometer to objectify sleep data. Vigor scores were high and sleepiness levels were low during the entire flight duty periods (FDPs), while vigilance was impaired only 6.8% in the course of the FDPs. Pre-duty sleep before morning duties was 1.5 h shorter than sleep before duties starting after midday. Longer pre-duty travel time was correlated with shorter pre-duty sleep and lower vigilance levels during duty. During the FDPs, pilots maintained alertness and vigilance levels that may be considered safe in terms of alertness-related flight safety. This favorable outcome may be attributed to reasonable length of FDPs, favorable circadian start and end times of duties, sufficient opportunities for restorative pre-duty sleep, and relatively good weather conditions. Appropriate FDP scheduling is an important measure to optimize alertness of helicopter pilots who have to cope with adverse environmental conditions and limited landing and air traffic control facilities.

  2. Comparison of posterior retroperitoneal and transabdominal lateral approaches in robotic adrenalectomy: an analysis of 200 cases.

    PubMed

    Kahramangil, Bora; Berber, Eren

    2018-04-01

    Although numerous studies have been published on robotic adrenalectomy (RA) in the literature, none has done a comparison of posterior retroperitoneal (PR) and transabdominal lateral (TL) approaches. The aim of this study was to compare the outcomes of robotic PR and TL adrenalectomy. This is a retrospective analysis of a prospectively maintained database. Between September 2008 and January 2017, perioperative outcomes of patients undergoing RA through PR and TL approaches were recorded into an IRB-approved database. Clinical and perioperative parameters were compared using Student's t test, Wilcoxon rank-sum test, and χ 2 test. Multivariate regression analysis was performed to determine factors associated with total operative time. 188 patients underwent 200 RAs. 110 patients were operated through TL and 78 patients through PR approach. Overall, conversion rate to open was 2.5% and 90-day morbidity 4.8%. The perioperative outcomes of TL and PR approaches were similar regarding estimated blood loss, rate of conversion to open, length of hospital stay, and 90-day morbidity. PR approach resulted in a shorter mean ± SD total operative time (136.3 ± 38.7 vs. 154.6 ± 48.4 min; p = 0.005) and lower visual analog scale pain score on postoperative day #1 (4.3 ± 2.5 vs. 5.4 ± 2.4; p = 0.001). After excluding tumors larger than 6 cm operated through TL approach, the difference in operative times persisted (136.3 ± 38.7 vs. 153.7 ± 45.7 min; p = 0.009). On multivariate regression analysis, increasing BMI and TL approaches were associated with longer total operative time. This study shows that robotic PR and TL approaches are equally safe and efficacious. With experience, shorter operative time and less postoperative pain can be achieved with PR technique. This supports the preferential utilization of PR approach in high-volume centers with enough experience.

  3. Three-dimensional printing enhances preparation for repair of double outlet right ventricular surgery.

    PubMed

    Zhao, Liyun; Zhou, Sijie; Fan, Taibing; Li, Bin; Liang, Weijie; Dong, Haoju

    2018-01-01

    To assess the clinical value of three-dimensional (3D) printing technology for treatment strategies for complex double outlet right ventricle (DORV). Twenty-five patients with complex double outlet right ventricle were enrolled in this study. The patients were divided into two groups: 3D printing group (eight patients) and a non-3-D printing control group (17 patients). The cardiac images of patients in the 3D printing group were transformed to Digital Imaging and Communications and were segmented and reconstructed to create a heart model. No cardiac models were created in the control group. A Pearson coefficient analysis was used to assess the correlation between measurements of 3D printed models and computed tomography angiography (CTA) data. Pre-operative assessment and planning were performed with 3D printed models, and then operative time and recovery time were compared between the two groups. There was good correlation (r = 0.977) between 3D printed models and CTA data. Patients in the 3D printing group had shorter aortic cross-clamp time (102.88 vs 127.76 min, P = 0.094) and cardiopulmonary bypass time (151.63 vs 184.24 min; P = 0.152) than patients in the control group. Patients with 3D printed models had significantly lower mechanical ventilation time (56.43 vs 96.76 h, P = 0.040) and significantly shorter intensive care unit time (99.04 vs 166.94 h, P = 0.008) than patients in the control group. 3D printed models can accurately demonstrate anatomic structures and are useful for pre-operative treatment strategies in DORV. © 2018 Wiley Periodicals, Inc.

  4. Single-incision versus conventional three-port laparoscopic appendectomy: A meta-analysis of randomized controlled trials.

    PubMed

    Chen, Jiang-Ming; Geng, Wei; Xie, Sheng-Xue; Liu, Fu-Bao; Zhao, Yi-Jun; Yu, Li-Quan; Geng, Xiao-Ping

    2015-01-01

    The aim of this article was to compare the advantages and disadvantages of single-incision laparoscopic appendectomy (SILA) and conventional three-port laparoscopic appendectomy (CTLA). A meta-analysis was performed by analyzing all randomized controlled trials (RCTs) published in English that compared SILA and CTLA for appendicitis in adults and children. These studies compared these two methods from different angles including outcomes of interest, patient characteristics, operative time, pain visual analogue scales scores (VAS scores), length of hospital stay, time to return to full activity, resumption of diet, postoperative complications and cosmetic results The risk ratios (RR) and mean difference (MD) with 95% confidence intervals (CIs) were employed to assess the outcome. Seven recent RCTs encompassing 1170 patients (586 SILA and 584 CTLA cases) were included in this meta-analysis. The pooled results demonstrated that conversion rate, drain inserted, reoperation, length of hospital stay, resumption of normal diet and postoperative complications were statistically comparable between the two groups. The postoperative abdominal pain within 24 h was -0.57 in favor of the SILA technique (p = 0.05). Compared with CTLA, SILA showed a better cosmetic satisfaction score (SMD, 0.58; 95% CI, 0.32-0.83; p < 0.0001) and shorter time to recover normal activity (WMD, -0.69; 95% CI, -1.11-0.26; p = 0.001). However, SILA has a longer operative time (WMD, 5.38; 95% CI, 2.94-7.83; p < 0.0001). In selected patients, SILA was confirmed to be as safe and effective as CTLA. Despite the longer operative time, SILA has higher cosmetic satisfaction and shorter recovery time to normal activity. Due to the limitations of the available data, further research is needed.

  5. [Intraoperational and postoperational complications of colo-rectal anastomosis prepared by classical and stapler techniques].

    PubMed

    Pasić, Fuad; Hasukić, Sefik; Serak, S; Mehmedagić, I; Mesić, Deso

    2008-01-01

    Resectional surgery on rectum, finishing with continued colo-rectal anastomosis by the classical manual technique, were burdened by a great number of post surgery complications of dehiscentio over 60%. If we take into reconsideration a high number of mortality 5-20% then we have valid reasons for developing modern and safer methods of surgical intervention of these patients. Two groups of 60 patients each, have been analyzed. They have been operated at the Surgical clinic University Clinical Center Tuzla because of rectum malignancy. The first group of patients where the colo-rectal anastomosis was manually operated was done between 1995-1998. In the second group of the patients being operated, colorectal continuity was done by stapler. The patients were operated in time period 2001-2002. The medium evaluation time was 20 months, for each group. All the patients were operated in elective programme, after endoscopic treatment and ph diagnosis done. The patients from the both analyzed groups were operated by the same surgeons. Preoperational procedure and postoperational observation was fullfilled according to the unified protocol. The patients with their colo-rectal continuity having been by stapler had a shorter surgery time, and less transfusion of blood. They had less ureter lesion. Also they have got a shorter hospitalization time with less number of anastomotic complications. Dehiscenc as well as bleeding. The patients with colorectal anastomosis made manually had more repeated surgeries. The patients from the manual group of the surgeries had more anastomotic relapses. The difference in the number of post operational strictures in both analyzed groups was not noticed. The patients with stapler colorectal anastomosis had no mortality. The manual group had one lethal case. The important thing that is noticed is a larger number of stapler colorectal anastomosis, not because of the illnes incidence increase but decrease of abdominoperineal rectum amputation. The patients have been safely operated from the oncologic point of wiev. They have continuing anastomosis which was not burdened with a larger number of morbidity and mortality. This was possible to do by improving surgical strategy and technique and introduction of stapler in every day surgical practice.

  6. Quantum gates by periodic driving

    PubMed Central

    Shi, Z. C.; Wang, W.; Yi, X. X.

    2016-01-01

    Topological quantum computation has been extensively studied in the past decades due to its robustness against decoherence. One way to realize the topological quantum computation is by adiabatic evolutions—it requires relatively long time to complete a gate, so the speed of quantum computation slows down. In this work, we present a method to realize single qubit quantum gates by periodic driving. Compared to adiabatic evolution, the single qubit gates can be realized at a fixed time much shorter than that by adiabatic evolution. The driving fields can be sinusoidal or square-well field. With the sinusoidal driving field, we derive an expression for the total operation time in the high-frequency limit, and an exact analytical expression for the evolution operator without any approximations is given for the square well driving. This study suggests that the period driving could provide us with a new direction in regulations of the operation time in topological quantum computation. PMID:26911900

  7. Quantum gates by periodic driving.

    PubMed

    Shi, Z C; Wang, W; Yi, X X

    2016-02-25

    Topological quantum computation has been extensively studied in the past decades due to its robustness against decoherence. One way to realize the topological quantum computation is by adiabatic evolutions-it requires relatively long time to complete a gate, so the speed of quantum computation slows down. In this work, we present a method to realize single qubit quantum gates by periodic driving. Compared to adiabatic evolution, the single qubit gates can be realized at a fixed time much shorter than that by adiabatic evolution. The driving fields can be sinusoidal or square-well field. With the sinusoidal driving field, we derive an expression for the total operation time in the high-frequency limit, and an exact analytical expression for the evolution operator without any approximations is given for the square well driving. This study suggests that the period driving could provide us with a new direction in regulations of the operation time in topological quantum computation.

  8. Comparative Short-Term Clinical Outcomes of Mediastinum Tumor Excision Performed by Conventional VATS and Single-Port VATS: Is It Worthwhile?

    PubMed

    Wu, Ching-Feng; Gonzalez-Rivas, Diego; Wen, Chih-Tsung; Liu, Yun-Hen; Wu, Yi-Cheng; Chao, Yin-Kai; Hsieh, Ming-Ju; Wu, Ching-Yang; Chen, Wei-Hsun

    2015-11-01

    Single-port video-assisted thoracoscopic surgery (VATS) has been widely applied recently. However, there are still only few reports describing its use in mediastinum tumor resection. We present the technique of single-port video-assisted thoracoscopic mediastinum tumor resection and compare it with conventional VATS with regard to short-term outcome.We retrospectively enrolled 105 patients who received mediastinum surgery in Chang Gung Memorial Hospital. Sixteen patients received sternotomy or thoracotomy, 29 patients received single-port VATS, and 60 patients received conventional VATS (3 ports). The operative time, blood loss, postoperation day 1 pain score, discharge day pain score, and postoperative hospital stay were compared. In order to establish a well balanced cohort study, we also use propensity scores match (1:1) to compare the short-term clinical outcome in 2 groups.No operative deaths occurred in this study. Single-port VATS was associated with shorter operative time, lower postoperation day 1 pain score, and shorter postoperation hospital stay in our cohort study (P = 0.001, <0.001, and 0.039), and propensity scores matched cohort study (P = 0.003, <0.001, and <0.001).Single-port VATS for mediastinum tumor appears to be a safe and promising technique with short-term outcome not inferior to conventional VATS in our cohort study. The long-term oncology outcome may require time and more enrolled patients to be further evaluated.

  9. Colonic exclusion and combined therapy for refractory constipation.

    PubMed

    Peng, Hong-Yun; Xu, Ai-Zhong

    2006-12-28

    To investigate the therapeutic effectiveness of colonic exclusion and combined therapy for refractory constipation. Thirty-two patients with refractory constipation were randomly divided into treatment group (n = 14) and control group (n = 18). Fourteen patients in treatment group underwent colonic exclusion and end-to-side colorectal anastomosis. Eighteen patients in control group received subtotal colectomy and end-to-end colorectal anastomosis. The therapeutic effects of the operations were assessed by comparing the surgical time, incision length, volume of blood losses, hospital stay, recovery rate and complication incidence. All patients received long-term follow-up. All operations were successful and patients recovered fully after the operations. In comparison of treatment group and control group, the surgical time (h), incision length (cm), volume of blood losses (mL), hospital stay (d) were 87 +/- 16 min vs 194 +/- 23 min (t = 9.85), 10.4 +/- 0.5 cm vs 21.2 +/- 1.8 cm (t = 14.26), 79.5 +/- 31.3 mL vs 286.3 +/- 49.2 mL (t = 17.24), and 11.8 +/- 2.4 d vs 18.6 +/- 2.6 d (t = 6.91), respectively (P < 0.001 for all). The recovery rate and complication incidence were 85.7% vs 88.9% (P = 0.14 > 0.05), 21.4% vs 33.3% (P = 0.73 > 0.05), respectively. Colonic exclusion has better therapeutic efficacy on refractory constipation. It has many advantages such as shorter surgical time, smaller incision, fewer blood losses and shorter hospital stay.

  10. OK432 versus doxycycline for treatment of macrocystic lymphatic malformations.

    PubMed

    Motz, Kevin M; Nickley, Katherine B; Bedwell, Joshua R; Yadav, Bhupender; Guzzetta, Philip C; Oh, Albert K; Bauman, Nancy M

    2014-02-01

    A variety of sclerotherapy agents are used to treat macrocystic lymphatic malformations (LMs). This retrospective study at a single institution was performed to compare the outcomes of pediatric macrocystic LMs of the head and neck that were treated with doxycycline or with OK432. The outcomes measured included early response to therapy, number of treatments required, operating room time, and adverse events. The rates of clinical success for OK432 and doxycycline were similar (83% and 82%, respectively; p > 0.05), although OK432-treated patients required more treatments than did doxycycline-treated patients (1.9 versus 1.0 injections; p = 0.01; 95% confidence interval, 1.57 to 0.27). The average operating room time for a single OK432 injection was significantly shorter than that for doxycycline (53.2 versus 98.1 minutes; p < 0.001); however, when the total number of treatments administered was considered, the overall times in the operating room were similar. Adverse events in the early postoperative period were more common in OK432-treated patients, who experienced marked postoperative swelling compared to doxycycline-treated patients. OK432 and doxycycline are both effective sclerosants for the treatment of predominantly macrocystic LMs. The administration time for OK432 is shorter than that for doxycycline, but OK432 required more treatments overall to achieve clinical success. Early adverse events were more common in OK432-treated patients, but longer follow-up is necessary to determine whether rates of recurrence and adverse events are similar, particularly in light of the risk of tooth discoloration in doxycycline-treated patients.

  11. Evaluation of Oral and Maxillofacial Surgery Residents' Operative Skills: Feasibility and Engagement Study Using SIMPL Software for a Mobile Phone.

    PubMed

    Kaban, Leonard B; Cappetta, Alyssa; George, Brian C; Lahey, Edward T; Bohnen, Jordan D; Troulis, Maria J

    2017-10-01

    There are no universally accepted tools to evaluate operative skills of surgical residents in a timely fashion. The purpose of this study was to determine the feasibility of using a smartphone application, SIMPL (System for Improving and Measuring Procedural Learning), developed by a multi-institutional research collaborative, to achieve a high rate of timely operative evaluations and resident communication and to collect performance data. The authors hypothesized that these goals would be achieved because the process is convenient and efficient. This was a prospective feasibility and engagement study using SIMPL to evaluate residents' operative skills. SIMPL requires the attending surgeon to answer 3 multiple-choice questions: 1) What level of help (Zwisch Scale) was required by the trainee? 2) What was the level of performance? 3) How complex was the case? The evaluator also can dictate a narrative. The sample was composed of 3 faculty members and 3 volunteer senior residents. Predictor variables were the surgeons, trainees, and procedures performed. Outcome variables included number and percentage of procedures performed by faculty-and-resident pairs assessed, time required to complete assessments, time lapsed to submission, percentage of assessments with narratives, and residents' response rates. From March through June 2016, 151 procedures were performed in the operating room by the faculty-and-resident teams. There were 107 assessments submitted (71%). Resident response (self-assessment) to faculty evaluations was 81%. Recorded time to complete assessments (n = 75 of 107) was shorter than 2 minutes. The time lapsed to submission was shorter than 72 hours (100%). Dictations were submitted for 35 evaluations (33%). Data for the type of help, performance, and complexity of cases were collected for each resident. SIMPL facilitates timely intraoperative evaluations of surgical skills, engagement by faculty and residents, and collection of detailed procedural data. Additional prospective trials to assess this tool further are planned. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. The Hand-Assisted Laparoscopic Approach to Resection of Pancreatic Mucinous Cystic Neoplasms: An Underused Technique?

    PubMed

    Postlewait, Lauren M; Ethun, Cecilia G; McInnis, Mia R; Merchant, Nipun; Parikh, Alexander; Idrees, Kamran; Isom, Chelsea A; Hawkins, William; Fields, Ryan C; Strand, Matthew; Weber, Sharon M; Cho, Clifford S; Salem, Ahmed; Martin, Robert C G; Scoggins, Charles; Bentrem, David; Kim, Hong J; Carr, Jacquelyn; Ahmad, Syed; Abbott, Daniel; Wilson, Gregory C; Kooby, David A; Maithel, Shishir K

    2018-01-01

    Pancreatic mucinous cystic neoplasms (MCNs) are rare tumors typically of the distal pancreas that harbor malignant potential. Although resection is recommended, data are limited on optimal operative approaches to distal pancreatectomy for MCN. MCN resections (2000-2014; eight institutions) were included. Outcomes of minimally invasive and open MCN resections were compared. A total of 289 patients underwent distal pancreatectomy for MCN: 136(47%) minimally invasive and 153(53%) open. Minimally invasive procedures were associated with smaller MCN size (3.9 vs 6.8 cm; P = 0.001), lower operative blood loss (192 vs 392 mL; P = 0.001), and shorter hospital stay(5 vs 7 days; P = 0.001) compared with open. Despite higher American Society of Anesthesiologists class, hand-assisted (n = 46) had similar advantages as laparoscopic/robotic (n = 76). When comparing hand-assisted to open, although MCN size was slightly smaller (4.1 vs 6.8 cm; P = 0.001), specimen length, operative time, and nodal yield were identical. Similar to laparoscopic/robotic, hand-assisted had lower operative blood loss (161 vs 392 mL; P = 0.001) and shorter hospital stay (5 vs 7 days; P = 0.03) compared with open, without increased complications. Hand-assisted laparoscopic technique is a useful approach for MCN resection because specimen length, lymph node yield, operative time, and complication profiles are similar to open procedures, but it still offers the advantages of a minimally invasive approach. Hand-assisted laparoscopy should be considered as an alternative to open technique or as a successive step before converting from total laparoscopic to open distal pancreatectomy for MCN.

  13. Discover cervical disc arthroplasty versus anterior cervical discectomy and fusion in symptomatic cervical disc diseases: A meta-analysis.

    PubMed

    Shangguan, Lei; Ning, Guang-Zhi; Tang, Yu; Wang, Zhe; Luo, Zhuo-Jing; Zhou, Yue

    2017-01-01

    Symptomatic cervical disc disease (SCDD) is a common degenerative disease, and Discover artificial cervical disc, a new-generation nonconstrained artificial disk, has been developed and performed gradually to treat it. We performed this meta-analysis to compare the efficacy and safety between Discover cervical disc arthroplasty (DCDA) and anterior cervical discectomy and fusion (ACDF) for SCDD. An exhaustive literature search of PubMed, EMBASE, and the Cochrane Library was conducted to identify randomized controlled trials that compared DCDA with ACDF for patients suffering SCDD. A random-effect model was used. Results were reported as standardized mean difference or risk ratio with 95% confidence interval. Of 33 articles identified, six studies were included. Compared with ACDF, DCDA demonstrated shorter operation time (P < 0.0001), and better range of motion (ROM) at the operative level (P < 0.00001). But no significant differences were observed in blood loss, neck disability index (NDI) scores, neck and arm pain scores, Japanese orthopaedic association (JOA) scores, secondary surgery procedures and adverse events (P > 0.05). Subgroup analyses did not demonstrated significant differences. In conclusion, DCDA presented shorter operation time, and better ROM at the operative level. However, no significant differences were observed in blood loss, NDI scores, neck and arm pain scores, JOA scores, secondary surgery procedures and adverse events between the two groups. Additionally, more studies of high quality with mid- to long-term follow-up are required in future.

  14. Ropivacaine for unilateral spinal anesthesia; hyperbaric or hypobaric?

    PubMed

    Cantürk, Mehmet; Kılcı, Oya; Ornek, Dilşen; Ozdogan, Levent; Pala, Yasar; Sen, Ozlem; Dikmen, Bayazit

    2012-01-01

    The aim of this study was to compare the unilaterality of subarachnoid block achieved with hyperbaric and hypobaric ropivacaine. The prospective, randomized trial was conducted in an orthopedics surgical suite. In all, 60 ASA I-III patients scheduled for elective total knee arthroplasty were included in the study. Group Hypo (n=30) received 11.25mg of ropivacaine (7.5mg.mL(-1)) + 2mL of distilled water (density at room temperature was 0.997) and group Hyper (n=30) received 11.25mg of ropivacaine (7.5mg.mL(-1)) + 2mL (5mg.mL(-1)) of dextrose (density at room temperature was 1,015). Patients in the hyperbaric group were positioned with the operated side down and in the 15° Fowler position, versus those in the hypobaric group with the operated side facing up and in the 15° Trendelenburg position. Combined spinal epidural anesthesia was performed midline at the L(3-4) lumbar interspace. Hemodynamic and spinal block parameters, regression time, success of unilateral spinal anesthesia, patient comfort, surgical comfort, surgeon comfort, first analgesic requirement time, and adverse effects were assessed. Time to reach the T10 dermatome level on the operated side was shorter in group Hyper (612.00±163.29s) than in group Hypo (763.63±208.35s) (p<0.05). Time to 2-segment regression of the sensory block level on both the operated and non-operated sides was shorter in group Hypo than in group Hyper. Both hyperbaric and hypobaric ropivacaine (11.25mg) provided adequate and dependable anesthesia for total knee replacement surgery, with a high level of patient and surgeon comfort. Hypobaric local anesthetic solutions provide a high level of unilateral anesthesia, with rapid recovery of both sensory and motor block, and therefore may be preferable in outpatient settings. Copyright © 2012 Elsevier Editora Ltda. All rights reserved.

  15. Retroperitoneal laparoscopic nephrectomy: the effect of the learning curve, and concentrating expertise, on operating times.

    PubMed

    Skinner, Adrian; Maoate, Kiki; Beasley, Spencer

    2010-05-01

    Laparoscopic nephrectomy is an accepted alternative to open nephrectomy. We analyzed our first 80 procedures of laparoscopic nephrectomy to evaluate the effect of experience and configuration of service on operative times. A retrospective review of 80 consecutive children who underwent retroperitoneal laparoscopic nephrectomy or heminephrectomy during an 11-year period from 1997 at Christchurch Hospital (Christchurch, New Zealand) was conducted. Operative times, in relation to the experience of the surgeon for this procedure, were analyzed. Four surgeons, assisted by an annually rotating trainee registrar, performed the procedure in 26 girls and 54 boys (range, 8 months to 15 years). Operating times ranged from 38 to 225 minutes (mean, 104). The average operative time fell from 105 to 90 minutes. One surgeon performed 40% of the procedures and assisted with a further 55%. The operative times for all surgeons showed a tendency to reduce, but this was not marked. Most procedures were performed by two surgeons working together, although one surgeon was involved in the majority of cases. The lead surgeon is often assisted by a fellow consultant colleague. Operative times were influenced by experience, but not markedly so. The shorter operative times and minimal "learning curve," compared with other reported series, may, in part, be due to the involvement of two surgeons experienced in laparoscopy for the majority of cases.

  16. Intervention on Surgical Systemic-to-Pulmonary Artery Shunts: Carotid Versus Femoral Access.

    PubMed

    Ligon, R Allen; Ooi, Yinn K; Kim, Dennis W; Vincent, Robert N; Petit, Christopher J

    2017-09-11

    The purpose of this study was to compare results between the femoral arterial (FA) and carotid arterial (CA) approaches in catheter-based interventions on Blalock-Taussig shunts (BTS). Transcatheter intervention on BTS is often performed in shunt-dependent, hypoxemic infants. The approach to BTS intervention likely has an impact on timeliness and overall success. The authors reviewed all cases of catheter intervention for BTS obstruction between 2012 and 2017 for their institution. They sought to compare procedural success rates and time, sheath time, time to arterial access, and time from access to stent implantation between FA and CA approaches. There were 42 BTS interventions between 34 patients. BTS intervention was more successful from the CA approach (p = 0.035). Among the FA cohort, BTS intervention was unsuccessful in 8 cases (25%), 5 of which were converted to CA with subsequent success. The CA cohort had lower procedure time (62 min vs. 104 min; p = 0.01) and anesthesia time (119 min vs. 151 min; p = 0.01). Additionally, CA access was associated with shorter time to arterial access (4.0 min vs. 9.3 min; p < 0.01), time to placement of the guidewire through the BTS (6.5 min vs. 13 min; p < 0.01), and time from the final sheath to BTS stent implantation (9 min vs. 20 min; p < 0.01). Operators should consider the route of access to the BTS deliberately. The authors' approach has been the carotid artery as an alternative access site-associated with greater procedural success, shorter procedural time, and shorter time to stent implantation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. The second “time-out”: a surgical safety checklist for lengthy robotic surgeries

    PubMed Central

    2013-01-01

    Robotic surgeries of long duration are associated with both increased risks to patients as well as distinct challenges for care providers. We propose a surgical checklist, to be completed during a second “time-out”, aimed at reducing peri-operative complications and addressing obstacles presented by lengthy robotic surgeries. A review of the literature was performed to identify the most common complications of robotic surgeries with extended operative times. A surgical checklist was developed with the goal of addressing these issues and maximizing patient safety. Extended operative times during robotic surgery increase patient risk for position-related complications and other adverse events. These cases also raise concerns for surgical, anesthesia, and nursing staff which are less common in shorter, non-robotic operations. Key elements of the checklist were designed to coordinate operative staff in verifying patient safety while addressing the unique concerns within each specialty. As robotic surgery is increasingly utilized, operations with long surgical times may become more common due to increased case complexity and surgeons overcoming the learning curve. A standardized surgical checklist, conducted three to four hours after the start of surgery, may enhance perioperative patient safety and quality of care. PMID:23731776

  18. Complete Versus Incomplete Angiography Prior to Percutaneous Coronary Intervention in ST-Elevation Myocardial Infarction.

    PubMed

    Stiver, Kevin; Gao, Xu; Shreenivas, Satya; Boudoulas, Konstantinos Dean; Mazzaferri, Ernie; Makki, Nader; Lilly, Scott M

    2017-08-01

    Shorter reperfusion times in ST-elevation myocardial infarction (STEMI) are associated with improved survival. Prehospital strategies have been developed to minimize door-to-balloon (DTB) time, but few strategies within the catheterization laboratory itself have been evaluated. Incomplete angiography (IA) prior to percutaneous coronary intervention (PCI) is undertaken in clinical practice as a means to further reduce DTB time. We sought to determine whether or not those with STEMI who underwent IA prior to PCI had different preprocedural characteristics or post-PCI outcomes. We retrospectively reviewed patients presenting to our institution between March 2013 and December 2015. Clinical, demographic, and angiographic data were reviewed. The frequency, predictors, and outcomes among those who received IA vs complete angiography (CA) prior to PCI were compared with analysis of variance. Two hundred fifty-six patients were identified; 68 patients (26.6%) underwent IA and 188 patients (73.4%) had CA prior to PCI. Patients who received IA were younger, but no other preprocedural factors were predictive of IA. The practice of IA did vary by operator (range, 0%-47%; P<.01). DTB times were shorter in the IA group (28.1 min vs 37.3 min; P<.01). Overall outcomes, including peak troponin values, length of stay, in-hospital mortality, and discharge ejection fraction did not differ between the groups. IA is associated with shorter DTB times, although in this population was not associated with improvements in short-term outcomes.

  19. Six years of evidence-based adult dissection tonsillectomy with ultrasonic scalpel, bipolar electrocautery, bipolar radiofrequency or 'cold steel' dissection.

    PubMed

    Ragab, S M

    2012-10-01

    To conduct an adequately powered, prospective, randomised, controlled trial comparing adult dissection tonsillectomy using either ultrasonic scalpel, bipolar electrocautery, bipolar radiofrequency or 'cold steel' dissection. Three hundred patients were randomised into four tonsillectomy technique groups. The operative time, intra-operative bleeding, post-operative pain, tonsillar fossa healing, return to full diet, return to work and post-operative complications were recorded. The bipolar radiofrequency group had a shorter mean operative time. The mean intra-operative blood loss during bipolar radiofrequency tonsillectomy was significantly less compared with cold dissection and ultrasonic scalpel tonsillectomy. Pain scores were significantly higher after bipolar electrocautery tonsillectomy. Patients undergoing bipolar electrocautery tonsillectomy required significantly more days to return to full diet and work. The bipolar electrocautery group showed significantly reduced tonsillar fossa healing during the first and second post-operative weeks. In this adult series, bipolar radiofrequency tonsillectomy was superior to ultrasonic, bipolar electrocautery and cold dissection tonsillectomies. This method combines the advantages of 'hot' and 'cold' tonsillectomy.

  20. Gelatin-thrombin hemostatic matrix in neurosurgical procedures: hemostasis effectiveness and economic value of clinical and surgical procedure-related benefits.

    PubMed

    Esposito, Felice; Cappabianca, Paolo; Angileri, Filippo F; Cavallo, Luigi M; Priola, Stefano M; Crimi, Salvatore; Solari, Domenico; Germanò, Antonino F; Tomasello, Francesco

    2016-07-26

    Gelatin-thrombin hemostatic matrix (FloSeal®) use is associated with shorter surgical times and less blood loss, parameters that are highly valued in neurosurgical procedures. We aimed to assess the effectiveness of gelatin-thrombin in neurosurgical procedures and estimate its economic value. In a 6-month retrospective evaluation at 2 hospitals, intraoperative and postoperative information were collected from patients undergoing neurosurgical procedures where bleeding was controlled with gelatin-thrombin matrix or according to local bleeding control guidelines (control group). Study endpoints were: length of surgery, estimated blood loss, hospitalization duration, blood units utilized, intensive care unit days, postoperative complications, and time-to-recovery. Statistical methods compared endpoints between the gelatin-thrombin and control groups and resource utilization costs were estimated. Seventy-eight patients (38 gelatin-thrombin; 40 control) were included. Gelatin-thrombin was associated with a shorter surgery duration than control 166±40 versus 185±55, p=0.0839); a lower estimated blood loss (185±80 versus 250±95ml; p=0.0017); a shorter hospital stay (10±3 versus 13±3 days; p<0.001); fewer intensive care unit days (10 days/3 patients and 20 days/4 patients); and shorter time-to-recovery (3±2.2 versus 4±2.8 weeks; p=0861). Fewer gelatin-thrombin patients experienced postoperative complications (3 minor) than the control group (5 minor; 3 major). No gelatin-thrombin patient required blood transfusion; 5 units were administered in the control group. The cost of gelatin-thrombin (€268.40/unit) was offset by the shorter surgery duration (difference of 19 minutes at €858 per hour) and the economic value of improved the other endpoint outcomes (ie, shorter hospital stay, less blood loss/lack of need for transfusion, fewer intensive care unit days, and complications). Gelatin-thrombin hemostatic matrix use in patients undergoing neurosurgical procedures was associated with better intra- and post-operative parameters than conventional hemostasis methods, with these parameters having substantial economic benefits.

  1. Impact of robotics on the outcome of elderly patients with endometrial cancer.

    PubMed

    Lavoue, Vincent; Zeng, Xing; Lau, Susie; Press, Joshua Z; Abitbol, Jeremie; Gotlieb, Raphael; How, Jeffrey; Wang, Yifan; Gotlieb, Walter H

    2014-06-01

    To evaluate the impact of introducing a robotics program on clinical outcome of elderly patients with endometrial cancer. Evaluation and comparison of peri-operative morbidity and disease-free interval in 163 consecutive elderly patients (≥70years) with endometrial cancer undergoing staging procedure with traditional open surgery compared to robotic surgery. All consecutive patients ≥70years of age with endometrial cancer who underwent robotic surgery (n=113) were compared with all consecutive patients ≥70years of age (n=50) before the introduction of a robotic program in December 2007. Baseline patient characteristics were similar in both eras. Patients undergoing robotic surgery had longer mean operating times (244 compared with 217minutes, p=0.009) but fewer minor adverse events (17% compared with 60%, p<0.001). The robotics cohort had less estimated mean blood loss (75 vs 334mL, p<0.0001) and shorter mean hospital stay (3 vs 6days, p<0.0001). There was no difference in disease-free survival (p=0.61) during the mean follow-up time of 2years. Transitioning from open surgery to a robotics program for the treatment of endometrial cancer in the elderly has significant benefits, including lower minor complication rate, less operative blood loss and shorter hospitalization without compromising 2-year disease-free survival. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. The Misgav-Ladach method of cesarean section: a step forward in operative technique in obstetrics.

    PubMed

    Hudić, Igor; Bujold, Emmanuel; Fatušić, Zlatan; Skokić, Fahrija; Latifagić, Anela; Kapidžić, Mirela; Fatušić, Jasenko

    2012-11-01

    The objective of this study is to compare the intraoperative and short-term outcomes of two cesarean techniques: the modified Misgav-Ladach and the Pfannenstiel-Kerr. We performed a prospective observational cohort study of women undergoing a primary cesarean at the Clinic for Obstetric and Gynecology Tuzla, Bosnia and Herzegovina, between January 2003 and December 2011. The two cesarean techniques were compared for intraoperative and short terms outcomes. A total of 4,944 women were included in this study, 4,336 allocated to the modified Misgav-Ladach and 608 to the Pfannenstiel-Kerr techniques. The rate of modified Misgav-Ladach increased from 74 % in 2003 to 99 % in 2011. The modified Misgav-Ladach technique was associated with a shorter operative time (13.3 min ± 7.4 vs. 19.1 min ± 6.8, p < 0.05), as well as significantly less surgical material (3.5 ± 2.5 vs. 7.9 ± 2.1, p < 0.05). The modified Misgav-Ladach technique was also associated with lower analgesic requirements, lower rates of febrile morbidity and wound infection compared to the Pfannenstiel-Kerr technique (p < 0.05). No significant differences were observed in the incidence of endometritis, wound dehiscence, bowel restitution, postoperative antibiotic use, and hospital stay. The modified Misgav-Ladach technique is associated with a shorter operative time than Pfannenstiel-Kerr and might lead to better postoperative outcomes.

  3. A systematic review and meta-analysis of randomized controlled trials comparing hysteroscopic morcellation with resectoscopy for patients with endometrial lesions.

    PubMed

    Li, Chunbo; Dai, Zhiyuan; Gong, Yuping; Xie, Bingying; Wang, Bei

    2017-01-01

    Results on the efficacy of hysteroscopic morcellation for patients with endometrial lesions remain conflicting. To compare hysteroscopic morcellation with conventional resectoscopy for removal of endometrial lesions. Electronic databases were searched for reports published up to February 1, 2016, using terms such as "morcellator," "morcellators," "morcellate," "morcellation," "morcellated," "hysteroscopy," "hysteroscopy," "uteroscope," and "transcervical." Randomized controlled trials were included if they assessed success rate, procedure speed, complications, tolerability, and/or learning curve. Data were extracted by two independent reviewers and a meta-analysis was performed. Four trials including 392 patients were analyzed. Successful removal of all endometrial lesions was more frequent with hysteroscopic morcellation than conventional resectoscopy (odds ratio 4.49, 95% confidence interval [CI] 1.94-10.41; P<0.001). Total operative time was also shorter with hysteroscopic morcellation (mean difference -4.94 minutes, 95% CI -7.20 to -2.68; P<0.001). No significant differences in complications were found. Meta-analyses were not possible for tolerability and learning curve. In one study, hysteroscopic morcellation was acceptable to more patients (P=0.009). Hysteroscopic morcellation is associated with a higher operative success rate and a shorter operative time among patients with endometrial lesions than is resectoscopy. More high-quality trials are required to validate these results. © 2016 International Federation of Gynecology and Obstetrics.

  4. Hypospadias and concomitant undescended testis: Comparison of no skin incision with inguinal and scrotal skin incision orchiopexy.

    PubMed

    Sabetkish, Shabnam; Kajbafzadeh, Abdol-Mohammad; Sabetkish, Nastaran

    2015-10-01

    To present the feasibility of no skin incision orchiopexy in children with concomitant hypospadias and undescended testis (UDT) by a single subcoronal incision technique. To introduce the creation of subdartos muscle scrotal pouch with no scrotal skin incision. From one thousand and twenty-one children with hypospadias, 61 patients presented with concomitant palpable UDT and hypospadias. In group I (N = 34) single subcoronal incision with no scrotal skin incision was applied. In group II (N = 27), multi-incision technique was applied for classical orchiopexy and hypospadias surgery. For hypospadias reconstruction, all patients had classical subcoronal and para urethral plate incision with penile skin degloving according to the location of urethral meatus. Early and late complications, surgical time, hospital stay, and cosmetic results were recorded. Children with unilateral UDT and hypospadias had one incision in group I and three skin incisions in group II. Patients with bilateral UDT had one incision in group I and five skin incisions in group II. The operation time was significantly shorter in group I (93 ± 11 min) compared with group II (138 ± 17 min) (P = 0.03). Both groups were operated as day care basis; however, the hospital stay was slightly longer in group II (group I = 12 ± 2 h, vs group II = 16 ± 3 h) (P = 0.07). All testes were satisfactorily positioned into the bottom of the scrotum without development of any testicular atrophy. Single subcoronal penile skin incision is a feasible, safe, and cosmetically satisfactory technique in patients with hypospadias and concomitant UDT. Reduced postoperative pain, better objective cosmetic results, shorter operative time and comfortable post-operative period are the most significant advantages of this approach. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  5. Antegrade versus retrograde cerebral perfusion for hemiarch replacement with deep hypothermic circulatory arrest: Does it matter? A propensity-matched analysis

    PubMed Central

    Ganapathi, Asvin M.; Hanna, Jennifer M.; Schechter, Matthew A.; Englum, Brian R.; Castleberry, Anthony W.; Gaca, Jeffrey G.; Hughes, G. Chad

    2015-01-01

    Objective The choice of cerebral perfusion strategy for aortic arch surgery has been debated, and the superiority of antegrade (ACP) or retrograde (RCP) cerebral perfusion has not been shown. We examined the early and late outcomes for ACP versus RCP in proximal (hemi-) arch replacement using deep hypothermic circulatory arrest (DHCA). Methods A retrospective analysis of a prospectively maintained database was performed for all patients undergoing elective and nonelective hemiarch replacement at a single referral institution from June 2005 to February 2013. Total arch cases were excluded to limit the analysis to shorter DHCA times and a more uniform patient population for whom clinical equipoise regarding ACP versus RCP exists. A total of 440 procedures were identified, with 360 (82%) using ACP and 80 (18%) using RCP. The endpoints included 30-day/in-hospital and late outcomes. A propensity score with 1:1 matching of 40 pre- and intraoperative variables was used to adjust for differences between the 2 groups. Results All 80 RCP patients were propensity matched to a cohort of 80 similar ACP patients. The pre- and intra-operative characteristics were not significantly different between the 2 groups after matching. No differences were found in 30-day/in-hospital mortality or morbidity outcomes. The only significant difference between the 2 groups was a shorter mean operative time in the RCP cohort (P = .01). No significant differences were noted in late survival (P = .90). Conclusions In proximal arch operations using DHCA, equivalent early and late outcomes can be achieved with RCP and ACP, although the mean operative time is significantly less with RCP, likely owing to avoidance of axillary cannulation. Questions remain regarding comparative outcomes with straight DHCA and lesser degrees of hypothermia. PMID:24908350

  6. Is the bipolar vessel sealer device an effective tool in robotic surgery? A retrospective analysis of our experience and a meta-analysis of the literature about different robotic procedures by investigating operative data and post-operative course.

    PubMed

    Ortenzi, Monica; Ghiselli, Roberto; Baldarelli, Maddalena; Cardinali, Luca; Guerrieri, Mario

    2018-04-01

    The latest robotic bipolar vessel sealing tools have been described to be effective allowing to perform procedures with reduced blood loss and shorter operative times. The aim of this study was to assess the efficacy and reliability of these devices applied in different robotic procedures. All robotic operations, between 2014 and 2016, were performed using the EndoWrist One VesselSealer (EWO, Intuitive Surgical, Sunnyvale, CA), a bipolar fully wristed device. Data, including age, gender, body mass index (BMI), were collected. Robot docking time, intraoperative blood loss, robot malfunctioning and overall operative time were analyzed. A meta-analysis of the literature was carried out to point the attention to three different parameters (mean blood loss, operating time and hospital stay) trying to identify how different coagulation devices may affect them. In 73 robotic procedures, the mean operative time was 118.2 minutes (75-125 minutes). Mean hospital stay was four days (2-10 days). There were two post-operative complications (2.74%). The bipolar vessel sealer offers the efficacy of bipolar diathermy and the advantages of a fully wristed instrument. It does not require any change of instruments for coagulation or involvement of the bedside assistant surgeon. These characteristics lead to a reduction in operative time.

  7. Genito-Urinary Function and Quality of Life after Elective Totally Laparoscopic Sigmoidectomy after at Least One Episode of Complicated Diverticular Disease According to Two Different Vascular Approaches: the IMA Low Ligation or the IMA Preservation.

    PubMed

    Mari, Giulio; Crippa, Jacopo; Costanzi, Andrea; Mazzola, Michele; Magistro, Carmelo; Ferrari, Giovanni; Maggioni, Dario

    2017-01-01

    The arterial ligation during elective laparoscopic sigmoidectomy for diverticular disease can affect genito-urinary function injuring the superior hypogastric plexus, and can weaken the distal colonic stump arterial perfusion. Ligation of the inferior mesenteric artery distal to the left colic artery or the complete preservation of the inferior mesenteric artery can therefore be compared in terms of preservation of the descending sympathetic fibres running along the aorta to the rectum resulting in a different post operative genito urinary function. From January 2015 to March 2016, 66 patients underwent elective laparoscopic sigmoidectomy for diverticular disease among two enrolling hospitals. In one centre 35 patients underwent laparoscopic sigmoidectomy with the ligation of the inferior mesenteric artery distal to the left colic artery (low ligation). In the other centre 31 patient were operated on the same procedure with complete inferior mesenteric artery preservation (IMA preservation). There was no difference in terms of major complication occurred, first passage of stool and length of hospital stay between the two groups. Time of surgery was significantly shorter in LL group compared to IMA preserving group and intra operative blood loss was significantly lower in the LL group. There were no differences in the genito urinary function between the two group pre operatively, at 1 and 9 months post operatively. Genito urinary function did not significantly change across surgery in each groups. The low ligation and the IMA preserving vascular approach are safe end feasible techniques in elective laparoscopic sigmoidectomy for diverticular disease. They both prevent from genito-urinary post-operative disfunction and allow good post operative quality of life. The low ligation approach is related to shorter operative time and slower intra operative blood loss. Celsius.

  8. Optimal Diabatic Dynamics of Majoarana-based Topological Qubits

    NASA Astrophysics Data System (ADS)

    Seradjeh, Babak; Rahmani, Armin; Franz, Marcel

    In topological quantum computing, unitary operations on qubits are performed by adiabatic braiding of non-Abelian quasiparticles such as Majorana zero modes and are protected from local environmental perturbations. This scheme requires slow operations. By using the Pontryagin's maximum principle, here we show the same quantum gates can be implemented in much shorter times through optimal diabatic pulses. While our fast diabatic gates no not enjoy topological protection, they provide significant practical advantages due to their optimal speed and remarkable robustness to calibration errors and noise. NSERC, CIfAR, NSF DMR- 1350663, BSF 2014345.

  9. A new modified speculum guided single nostril technique for endoscopic transnasal transsphenoidal surgery: an analysis of nasal complications.

    PubMed

    Waran, Vicknes; Tang, Ing Ping; Karuppiah, Ravindran; Abd Kadir, Khairul Azmi; Chandran, Hari; Muthusamy, Kalai Arasu; Prepageran, Narayanan

    2013-12-01

    Abstract The endoscopic transnasal, transsphenoidal surgical technique for pituitary tumour excision has generally been regarded as a less invasive technique, ranging from single nostril to dual nostril techniques. We propose a single nostril technique using a modified nasal speculum as a preferred technique. We initially reviewed 25 patients who underwent pituitary tumour excision, via endoscopic transnasal transsphenoidal surgery, using this new modified speculum-guided single nostril technique. The results show shorter operation time with reduced intra- and post-operative nasal soft tissue injuries and complications.

  10. Outcomes of robotic, laparoscopic and open hysterectomy for benign conditions in obese patients.

    PubMed

    Borahay, Mostafa A; Tapısız, Ömer Lütfi; Alanbay, İbrahim; Kılıç, Gökhan Sami

    2018-04-27

    To compare outcomes of robotic assisted (RAH), total laparoscopic (LH) and total abdominal (TAH) hysterectomy for benign conditions in obese patients. Retrospective cohort (Class II-2) analysis. All obese patients who underwent RAH, LH or TAH for benign conditions by a single surgeon at the University of Texas Medical Branch between January 2009 and December 2011 were identified and their charts reviewed. Patients' characteristics, operative data and post-operative outcomes were collected and statistically analyzed. A total of 208 patients who underwent RAH ( n= 51 ), LH ( n=24 ) or TAH ( n=133 ) were analyzed. There were no significant differences among groups in demographic characteristics, indications for surgery or pathologic findings. RAH and LH were associated with less estimated blood loss (EBL) ( P < .001) and shorter length of hospital stay (LOS) ( P < .001) compared to TAH. In addition, RAH and LH had lower intraoperative and early postoperative (≤ 6 weeks) complications compared with TAH ( P = .002). However, the procedure time was longer in RAH and LH ( P < .001). No significant differences were noted among groups for late post-operative complications (after 6 weeks) or unscheduled post-operative visits. Minimally invasive hysterectomy appears to be safe in obese patients with the advantages of less EBL, fewer intraoperative complications and shorter LOS.

  11. Comparison of pediatric appendectomy outcomes between pediatric surgeons and general surgery residents.

    PubMed

    Mizrahi, Ido; Mazeh, Haggi; Levy, Yair; Karavani, Gilad; Ghanem, Muhammad; Armon, Yaron; Vromen, Amos; Eid, Ahmed; Udassin, Raphael

    2013-04-01

    Appendectomy is the most common urgent procedure in children, and surgical outcomes may be affected by the surgeon's experience. This study's aim is to compare appendectomy outcomes performed by pediatric surgeons (PSs) and general surgery residents (GSRs). A retrospective review of all patients younger than 16y treated for appendicitis at two different campuses of the same institution during the years 2008-2009 was performed. Appendectomies were performed by PS in one campus and GSR in the other. Primary end points included postoperative morbidity and hospital length of stay. During the study period, 246 (61%) patients were operated by senior GSR (postgraduate year 5-7) versus 157 (39%) patients by PS. There was no significant difference in patients' characteristics at presentation to the emergency room and the rate of appendeceal perforation (11% versus 15%, P=0.32), and noninfectious appendicitis (5% versus 5% P=0.78) also was similar. Laparoscopic surgery was performed more commonly by GSR (16% versus 9%, P=0.02) with shorter operating time (54±1.5 versus 60±2.1, P=0.01). Interestingly, the emergency room to operating room time was shorter for GSR group (419±14 versus 529±24min, P<0.001). The hospital length of stay was shorter for the GSR group (4.0±0.2 versus 4.5±0.2, P=0.03), and broad-spectrum antibiotics were used less commonly (20% versus 53%, P<0.0001) and so was home antibiotics continuation (13% versus 30%, P<0.0001). Nevertheless, postoperative complication rate was similar (5% versus 7%, P=0.29) and so was the rate of readmissions (2% versus 5%, P=0.52). The results of this study suggest that the presence of a PS does not affect the outcomes of appendectomies. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Treatment of first metatarsophalangeal joint arthritis using hemiarthroplasty with a synthetic cartilage implant or arthrodesis: A comparison of operative and recovery time.

    PubMed

    Glazebrook, Mark; Younger, Alastair S E; Daniels, Timothy R; Singh, Dishan; Blundell, Chris; de Vries, Gwyneth; Le, Ian L D; Nielsen, Dominic; Pedersen, M Elizabeth; Sakellariou, Anthony; Solan, Matthew; Wansbrough, Guy; Baumhauer, Judith F

    2017-05-29

    First metatarsophalangeal joint (MTPJ1) hemiarthroplasty using a novel synthetic cartilage implant was as effective and safe as MTPJ1 arthrodesis in a randomized clinical trial. We retrospectively evaluated operative time and recovery period for implant hemiarthroplasty (n=152) and MTPJ1 arthrodesis (n=50). Perioperative data were assessed for operative and anaesthesia times. Recovery and return to function were prospectively assessed with the Foot and Ankle Ability Measure (FAAM) Sports and Activities of Daily Living (ADL) subscales and SF-36 Physical Functioning (PF) subscore. Mean operative time for hemiarthroplasty was 35±12.3min and 58±21.5min for arthrodesis (p<0.001). Anaesthesia duration was 28min shorter with hemiarthroplasty (p<0.001). At weeks 2 and 6 postoperative, hemiarthroplasty patients demonstrated clinically and statistically significantly higher FAAM Sport, FAAM ADL, and SF-36 PF subscores versus arthrodesis patients. MTPJ1 hemiarthroplasty with a synthetic cartilage implant took less operative time and resulted in faster recovery than arthrodesis. III, Retrospective case control study. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  13. Comparing Zero Ischemia Laparoscopic Radio Frequency Ablation Assisted Tumor Enucleation and Laparoscopic Partial Nephrectomy for Clinical T1a Renal Tumor: A Randomized Clinical Trial.

    PubMed

    Huang, Jiwei; Zhang, Jin; Wang, Yanqing; Kong, Wen; Xue, Wei; Liu, Dongming; Chen, YongHui; Huang, Yiran

    2016-06-01

    We evaluated the functional outcome, safety and efficacy of zero ischemia laparoscopic radio frequency ablation assisted tumor enucleation compared with conventional laparoscopic partial nephrectomy. A prospective randomized controlled trial was conducted from April 2013 to March 2015 in patients with cT1a renal tumor scheduled for laparoscopic nephron sparing surgery. All patients were followed for at least 12 months. Patients in the laparoscopic radio frequency ablation assisted tumor enucleation group underwent tumor enucleation after radio frequency ablation without hilar clamping. The primary outcome was the change in glomerular filtration rate of the affected kidney by renal scintigraphy at 12 months. Secondary outcomes included changes in estimated glomerular filtration rate, estimated blood loss, operative time, hospital stay, postoperative complications and oncologic outcomes. The Pearson chi-square or Fisher exact, Student t-test and Wilcoxon rank sum tests were used. The trial ultimately enrolled 89 patients, of whom 44 were randomized to the laparoscopic radio frequency ablation assisted tumor enucleation group and 45 to the laparoscopic partial nephrectomy group. In the laparoscopic partial nephrectomy group 1 case was converted to radical nephrectomy. Compared with the laparoscopic partial nephrectomy group, patients in the laparoscopic radio frequency ablation assisted tumor enucleation group had a smaller decrease in glomerular filtration rate of the affected kidney at 3 months (10.2% vs 20.5%, p=0.001) and 12 months (7.6% vs 16.2%, p=0.002). Patients in the laparoscopic radio frequency ablation assisted tumor enucleation group had a shorter operative time (p=0.002), lower estimated blood loss (p <0.001) and a shorter hospital stay (p=0.029) but similar postoperative complications (p=1.000). There were no positive margins or local recurrence in this study. Zero ischemia laparoscopic radio frequency ablation assisted tumor enucleation enables tumor excision with better renal function preservation compared to conventional laparoscopic partial nephrectomy. Less blood loss and a shorter operative time were achieved with similar postoperative complication rates. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  14. Histopathological and Postoperative Behavioral Comparison of Rodent Oral Tongue Resection: Fiber-Enabled CO2 Laser versus Electrocautery

    PubMed Central

    Shires, Courtney Brooke; Saputra, Jennifer Marie; King, Lauren; Thompson, Jerome W.; Heck, Detlef H.; Sebelik, Merry Ellen; Boughter, John Dudley

    2015-01-01

    Objective To compare operative time and hemostasis of fiber-enabled CO2 laser (FECL) energy to that of the electrocautery (EC) technique for oral tongue resection, to compare return to oral intake and preoperative weight after FECL and EC resection, and to compare histologic changes in adjacent tissue after FECL and EC resection. Study Design Prospective animal study. Setting Research laboratory. Subjects and Methods The CO2 laser fiber and the Bovie cautery were each used to resect the anterior tongue in 15 adult rats. Fixative perfusion and killing were performed on postoperative day 0 (n = 10), 3 (n = 10), or 7 (n = 10). Body weight, food intake, and water intake were recorded daily for 3- and 7-day survival rats. After preparation for histologic analysis, the tongue tissue was graded with a mucosal wound-healing scale (MWHS). Results A higher incidence of intraoperative bleeding and shorter operative times were noted in the EC group. No statistically significant difference in postoperative food or water intake between the EC and FECL groups was noted. The FECL group returned to baseline weight by postoperative day 6. MWHS scores were lower in the EC group by postoperative day 3 and lower in the FECL group by postoperative day 7. Conclusions Both EC and FECL are effective for resection of the tongue in rats. EC has the advantage of shorter operative time and lower MWHS scores by postoperative day 3; FECL has the advantages of less intraoperative bleeding, faster return to baseline body weight, and lower MWHS score by postoperative day 7. PMID:22535916

  15. Laparoscopic skill improvement after virtual reality simulator training in medical students as assessed by augmented reality simulator.

    PubMed

    Nomura, Tsutomu; Mamada, Yasuhiro; Nakamura, Yoshiharu; Matsutani, Takeshi; Hagiwara, Nobutoshi; Fujita, Isturo; Mizuguchi, Yoshiaki; Fujikura, Terumichi; Miyashita, Masao; Uchida, Eiji

    2015-11-01

    Definitive assessment of laparoscopic skill improvement after virtual reality simulator training is best obtained during an actual operation. However, this is impossible in medical students. Therefore, we developed an alternative assessment technique using an augmented reality simulator. Nineteen medical students completed a 6-week training program using a virtual reality simulator (LapSim). The pretest and post-test were performed using an object-positioning module and cholecystectomy on an augmented reality simulator(ProMIS). The mean performance measures between pre- and post-training on the LapSim were compared with a paired t-test. In the object-positioning module, the execution time of the task (P < 0.001), left and right instrument path length (P = 0.001), and left and right instrument economy of movement (P < 0.001) were significantly shorter after than before the LapSim training. With respect to improvement in laparoscopic cholecystectomy using a gallbladder model, the execution time to identify, clip, and cut the cystic duct and cystic artery as well as the execution time to dissect the gallbladder away from the liver bed were both significantly shorter after than before the LapSim training (P = 0.01). Our training curriculum using a virtual reality simulator improved the operative skills of medical students as objectively evaluated by assessment using an augmented reality simulator instead of an actual operation. We hope that these findings help to establish an effective training program for medical students. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  16. Laparoscopic versus open distal pancreatectomy-a propensity score-matched analysis from the German StuDoQ|Pancreas registry.

    PubMed

    Wellner, Ulrich Friedrich; Lapshyn, Hryhoriy; Bartsch, Detlef K; Mintziras, Ioannis; Hopt, Ulrich Theodor; Wittel, Uwe; Krämling, Hans-Jörg; Preissinger-Heinzel, Hubert; Anthuber, Matthias; Geissler, Bernd; Köninger, Jörg; Feilhauer, Katharina; Hommann, Merten; Peter, Luisa; Nüssler, Natascha C; Klier, Thomas; Mansmann, Ulrich; Keck, Tobias

    2017-02-01

    The aim of this study was to assess intraoperative, postoperative, and oncologic outcome in patients undergoing laparoscopic distal pancreatectomy (LDP) versus open distal pancreatectomy (ODP) for benign and malignant lesions of the pancreas. Data from patients undergoing distal pancreatic resection were extracted from the StuDoQ|Pancreas registry of the German Society for General and Visceral Surgery. After propensity score case matching, groups of LDP and ODP were compared regarding demography, comorbidities, operative details, histopathology, and perioperative outcome. At the time of data extraction, the StuDoQ|Pancreas registry included over 3000 pancreatic resections from over 50 surgical departments in Germany. Data from 353 patients undergoing ODP (n = 254) or LDP (n = 99) from September 2013 to February 2016 at 29 institutions were included in the analysis. Baseline data showed a strong selection bias in LDP patients, which disappeared after 1:1 propensity score matching. A comparison of the matched groups disclosed a significantly longer operation time, higher rate of spleen preservation, more grade A pancreatic fistula, shorter hospital stay, and increased readmissions for LDP. In the small group of patients operated for pancreatic cancer, a lower lymph node yield with a lower lymph node ratio was apparent in LDP. LDP needed more time but potential advantages include increased spleen preservation and shorter hospital stay, as well as a trend for less transfusion, ventilation, and mortality. LDP for pancreatic cancer was performed rarely and will need critical evaluation in the future. Data from a prospective randomized registry trial is needed to confirm these results.

  17. Hydraulic retention time and pH affect the performance and microbial communities of passive bioreactors for treatment of acid mine drainage.

    PubMed

    Aoyagi, Tomo; Hamai, Takaya; Hori, Tomoyuki; Sato, Yuki; Kobayashi, Mikio; Sato, Yuya; Inaba, Tomohiro; Ogata, Atsushi; Habe, Hiroshi; Sakata, Takeshi

    2017-12-01

    For acceleration of removing toxic metals from acid mine drainage (AMD), the effects of hydraulic retention time (HRT) and pH on the reactor performance and microbial community structure in the depth direction of a laboratory-scale packed-bed bioreactor containing rice bran as waste organic material were investigated. The HRT was shortened stepwise from 25 to 12 h, 8 h, and 6 to 5 h under the neutral condition using AMD neutralized with limestone (pH 6.3), and from 25 to 20 h, 12 h, and 8 to 7 h under the acid condition using AMD (pH 3.0). Under the neutral condition, the bioreactor stably operated up to 6 h HRT, which was shorter than under the acid condition (up to 20 h HRT). During stable sulfate reduction, both the organic matter-remaining condition and the low oxidation-reduction potential condition in lower parts of the reactor were observed. Principal coordinate analysis of Illumina sequencing data of 16S rRNA genes revealed a dynamic transition of the microbial communities at the boundary between stable and unstable operation in response to reductions in HRT. During stable operation under both the neutral and acid conditions, several fermentative operational taxonomic units (OTUs) from the phyla Firmicutes and Bacteroidetes dominated in lower parts of the bioreactor, suggesting that co-existence of these OTUs might lead to metabolic activation of sulfate-reducing bacteria. In contrast, during unstable operation at shorter HRTs, an OTU from the candidate phylum OP11 were found under both conditions. This study demonstrated that these microorganisms can be used to monitor the treatment of AMD, which suggests stable or deteriorated performance of the system.

  18. Utilization of Total Joint Arthroplasty in Physician-Owned Specialty Hospitals vs Acute Care Facilities.

    PubMed

    Chen, Antonia F; Pflug, Emily; O'Brien, Daniel; Maltenfort, Mitchell G; Parvizi, Javad

    2017-07-01

    The recent emergence of physician-owned specialty hospitals has sparked controversy about overutilization. Thus, the purpose of this study was to compare utilization patterns of total joint arthroplasty (TJA) between physician-specialty hospitals (PSHs) and acute care hospitals (ACHs). A retrospective study was conducted from January 2010 to August 2014 comparing primary TJA patients between a PSH and an ACH; 103 PSH patients were matched to 103 ACH patients by age, gender, BMI, and ASA classification with similar case distribution between facilities. All surgeons in the study operated at both hospitals and were shareholders of the PSH. Information on nonoperative treatments, and timing to the initial appointment, consent, and surgery were analyzed using univariate analysis. Nonoperative treatments before surgery were similar between hospitals (P = 1.00). The time from the initial appointment to consent was longer for PSH (P = .0001). However, the time from consent to the date of surgery (P = .04) and the timing from symptoms to initial appointment (P = .006) was shorter for PSH. The time from initial appointment to the day of surgery was similar between groups (P = .20). Patients were more likely to be consented for surgery on their first clinic visit when undergoing surgery at ACH (87 of 103, 84.4%) compared to PSH (61 of 103; 59.2%; P < .001). Length of stay was significantly shorter for both total knee arthroplasty (P = .001) and total hip arthroplasty patients (P = .001) at PSH. Facility ownership in PSH resulted in similar conservative treatment before TJA. The time to surgical consent after the initial appointment was longer PSH, whereas the time from consent to the date of surgery was shorter at the PSH. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Congenital Morgagni's hernia: a national multicenter study.

    PubMed

    Al-Salem, Ahmed H; Zamakhshary, Mohammed; Al Mohaidly, Mohammed; Al-Qahtani, Aayed; Abdulla, Mohamed Ramadan; Naga, Mohamed Ibrahim

    2014-04-01

    Congenital Morgagni's hernia (CMH) is rare and represents less than 5% of all congenital diaphragmatic hernias. This is a national review of our experience with CMH outlining clinical presentation, methods of diagnosis, associated anomalies, treatment, and outcome. The medical records of all patients with the diagnosis of CMH treated at four pediatric surgery units in Saudi Arabia were retrospectively reviewed for age at diagnosis, sex, presenting symptoms, associated anomalies, diagnosis, operative findings, treatment, and outcome. During a 20-year period (January 1990-December 2010), 53 infants and children with CMH were treated. There were 38 males and 15 females. Their age at diagnosis ranged from 1 month to 9 years (mean 22.2 months). Forty-three (81%) presented with recurrent chest infection. Twenty-two (44.5%) had right CMH, 15 (28.3%) had left-sided hernia and 16 (30.2%) had bilateral hernia. In 7, the diagnosis of bilaterality was made at the time of surgery. Associated anomalies were seen in 38 (71.7%). Twenty-one (39.6%) had congenital heart disease, 8 (15%) had malrotation, and 15 (28.3%) had Down syndrome. All were operated on. Twenty-nine (54.7%) underwent repair via an open approach. The remaining 24 (45.3%) underwent repair using minimal invasive surgery, laparoscopic-assisted hernia repair (19 patients) or totally laparoscopic approach (5 patients). At the time of surgery, the hernia sac content included the colon in 33 (62.3%), part of the left lobe of the liver in 13 (24.5%), the small intestines in 11 (20.75%), the omentum in 5 (9.4%), and the stomach in 4 (7.5%). In 12 (22.6%), the hernia sac was empty. When compared to the open repair, the laparoscopic-assisted approach was associated with a shorter operative time, an earlier commencement of feeds, less requirement for postoperative analgesia, a shorter hospital stay, and better cosmetic appearance. There was no mortality. On follow-up, 2 (7%) of the open surgical group developed recurrence. CMH is rare and in the pediatric age group commonly presents with recurrent chest infection and has a high incidence of associated anomalies, commonly congenital heart disease and Down syndrome. We advocate a laparoscopic-assisted approach to repair CMH. This is a simple technique that produces a sound repair, and when compared with the open approach it takes less operative time, requires less analgesia, allows earlier commencement of feeds, is associated with a shorter hospital stay, and has a better cosmetic outcome. © 2013 Elsevier Inc. All rights reserved.

  20. Pump-probe experiments at the TEMPO beamline using the low-α operation mode of Synchrotron SOLEIL.

    PubMed

    Silly, Mathieu G; Ferté, Tom; Tordeux, Marie Agnes; Pierucci, Debora; Beaulieu, Nathan; Chauvet, Christian; Pressacco, Federico; Sirotti, Fausto; Popescu, Horia; Lopez-Flores, Victor; Tortarolo, Marina; Sacchi, Maurizio; Jaouen, Nicolas; Hollander, Philippe; Ricaud, Jean Paul; Bergeard, Nicolas; Boeglin, Christine; Tudu, Bharati; Delaunay, Renaud; Luning, Jan; Malinowski, Gregory; Hehn, Michel; Baumier, Cédric; Fortuna, Franck; Krizmancic, Damjan; Stebel, Luigi; Sergo, Rudi; Cautero, Giuseppe

    2017-07-01

    The SOLEIL synchrotron radiation source is regularly operated in special filling modes dedicated to pump-probe experiments. Among others, the low-α mode operation is characterized by shorter pulse duration and represents the natural bridge between 50 ps synchrotron pulses and femtosecond experiments. Here, the capabilities in low-α mode of the experimental set-ups developed at the TEMPO beamline to perform pump-probe experiments with soft X-rays based on photoelectron or photon detection are presented. A 282 kHz repetition-rate femtosecond laser is synchronized with the synchrotron radiation time structure to induce fast electronic and/or magnetic excitations. Detection is performed using a two-dimensional space resolution plus time resolution detector based on microchannel plates equipped with a delay line. Results of time-resolved photoelectron spectroscopy, circular dichroism and magnetic scattering experiments are reported, and their respective advantages and limitations in the framework of high-time-resolution pump-probe experiments compared and discussed.

  1. Accelerated recovery from sevoflurane anesthesia with isocapnic hyperpnoea.

    PubMed

    Katznelson, Rita; Minkovich, Leonid; Friedman, Zeev; Fedorko, Ludvik; Beattie, W Scott; Fisher, Joseph A

    2008-02-01

    Isocapnic hyperpnoea (IH) reduces recovery time from isoflurane anesthesia in animals and humans. We studied the effect of IH on the emergence profile of sevoflurane-anesthetized patients by comparing postoperative recovery variables in patients administered IH (IH group) to those recovered in the customary fashion (control group). We enrolled 30 ASA I-III patients undergoing elective gynecological surgery. Induction and maintenance of anesthesia were standardized with a protocol consisting of fentanyl, propofol, rocuronium, and sevoflurane in air/O2. Patients were randomly assigned to control (C) or IH groups at the end of the surgery. We recorded time intervals from discontinuing sevoflurane to recovery milestones. Time to tracheal extubation was much shorter in the IH group compared with group C (6.2 +/- 2.1 vs 12.3 +/- 3.8 min, respectively, P < 0.01). The IH group also had shorter times to initiation of spontaneous ventilation (4.2 +/- 1.7 vs 6.5 +/- 3.8 min, P = 0.047), eye opening (5.5 +/- 1.4 vs 13.3 +/- 4.4 min, P < 0.01), bispectral index value >75 (3.9 +/- 1.1 vs 8.8 +/- 3.7 min, P < 0.01), leaving operating room (7.7 +/- 2.0 vs 15.3 +/- 3.4 min, P < 0.01), and eligibility for postanesthetic care unit discharge (67.2 +/- 19.3 vs 90.6 +/- 20.0 min, P < 0.01). IH accelerates recovery from sevoflurane anesthesia and shortens operating room and postanesthetic care unit stay.

  2. Intralesional curettage of central low-grade chondrosarcoma: A midterm follow-up study.

    PubMed

    Chen, Yi-Chou; Wu, Po-Kuei; Chen, Cheng-Fong; Chen, Wei-Ming

    2017-03-01

    The aim of this study was to review the experience of surgical treatment of low-grade chondrosarcoma and to assess the long-term oncological and functional outcomes between intralesional curettage and wide excision. We included 11 patients with central low-grade chondrosarcoma lesions treated with intralesional curettage or wide excision from 1998 to 2013. Seven patients were treated with intralesional curettage and local adjuvant treatment (Group A), and four patients were treated with wide excision and reconstructive surgery (Group B). The mean age of patients was 43.8±17.6 years (range, 20-71 years), and the mean duration of follow-up was 84.4±47.6 months (range, 48-194 months). Group A had a significantly lower complication rate than Group B; three complications were documented in Group B (0% vs. 75%, p=0.024). The operative time (177.1 hours vs. 366.3 hours, p=0.010) and the hospital stay (6.6 days vs. 12.5 days, p=0.010) were significantly shorter in Group A. There was one local recurrence in Group A without statistical significance. Also, there were no differences between intralesional curettage and wide excision with respect to the blood loss. No metastasis disease occurred in either group during the follow-up period. The Musculoskeletal Tumor Society (MSTS) scores in Groups A and B were 99.0±2.5 and 94.2±4.2, respectively, with statistically significant difference (p=0.048). Extended intralesional curettage has the benefits of good MSTS score, shorter operative time, shorter hospital stay, and lower complication rate without increasing local recurrence in central low-grade chondrosarcoma. For central low-grade chondrosarcoma, we suggest extended curettage to decrease soft tissue damage and surgical risk. Copyright © 2016. Published by Elsevier Taiwan LLC.

  3. The increase in the starting torque of PMSM motor by applying of FOC method

    NASA Astrophysics Data System (ADS)

    Plachta, Kamil

    2017-05-01

    The article presents field oriented control method of synchronous permanent magnet motor equipped in optical sensors. This method allows for a wide range regulation of torque and rotational speed of the electric motor. The paper presents mathematical model of electric motor and vector control method. Optical sensors have shorter time response as compared to the inductive sensors, which allow for faster response of the electronic control system to changes of motor loads. The motor driver is based on the digital signal processor which performs advanced mathematical operations in real time. The appliance of Clark and Park transformation in the software defines the angle of rotor position. The presented solution provides smooth adjustment of the rotational speed in the first operating zone and reduces the dead zone of the torque in the second and third operating zones.

  4. Working hours as a risk factor in the development of musculoskeletal complaints.

    PubMed

    Waersted, M; Westgaard, R H

    1991-03-01

    The length of daily working hours as a risk factor for the development of musculoskeletal complaints was studied by comparing the sick leave statistics of 408 sewing machine operators on full-time schedules (8 h working day) with 210 operators on part-time schedules (5 h working day). Working part-time was shown to postpone the occurrence of sick leave due to musculoskeletal disorders by approximately half a year. There was no lasting effect on the reduction in working hours on sick leave due to shoulder-neck complaints, but a reduction in low back complaints was indicated. It is suggested that any reorganization of work activities to counteract musculoskeletal injuries from repetitive work should aim to break up the muscular activity patterns over time periods considerably shorter than the 5 h working day of the part-time workers in the present study.

  5. Efficacy of Gastrografin® Compared with Standard Conservative Treatment in Management of Adhesive Small Bowel Obstruction at Mulago National Referral Hospital

    PubMed Central

    Haule, Caspar; Ongom, Peter A; Kimuli, Timothy

    2013-01-01

    Introduction The treatment of adhesive small bowel obstruction is controversial, with both operative and non-operative management practiced in different centers worldwide. Non-operative management is increasingly getting popular, though operative rates still remain high. A study to compare the efficacy of an oral water-soluble medium (Gastrografin®) with standard conservative management, both non-operative methods, in the management of this condition was conducted in a tertiary Sub Saharan hospital. Methods An open randomised controlled clinical trial was conducted between September 2012 and March 2013 at Mulago National Referral and Teaching Hospital, Uganda. Fifty patients of both genders, with adhesive small bowel obstruction, in the hospital’s emergency and general surgical wards were included. Randomisation was to Gastrografin® and standard conservative treatment groups. The primary outcomes were: the time interval between admission and relief of obstruction, the length of hospital stay, and the rates of operative surgery. Results All 50 recruited patients were followed up and analysed; 25 for each group. In the Gastrografin® group, 22 (88%) patients had relief of obstruction following the intervention, with 3 (12%) requiring surgery. The conservative treatment group had 16 (64%) patients relieved of obstruction conservatively, and 9 (36%) required surgery. The difference in operative rates between the two groups was not statistically significance (P = 0.67). Average time to relief of obstruction was shorter in the Gastrografin® group (72.52 hrs) compared to the conservative treatment group (117.75 hrs), a significant difference (P = 0.023). The average length of hospital stay was shorter in the Gastrografin® group (5.62 days) compared to the conservative treatment group (10.88 days), a significant difference (P = 0.04). Conclusion The use of Gastrografin® in patients with adhesive small bowel obstruction helps in earlier resolution of obstruction and reduces the length of hospital stay compared with standard conservative management. Its role in reducing the rate of laparotomies remains inconclusive. PMID:24729947

  6. Efficacy of Gastrografin® Compared with Standard Conservative Treatment in Management of Adhesive Small Bowel Obstruction at Mulago National Referral Hospital.

    PubMed

    Haule, Caspar; Ongom, Peter A; Kimuli, Timothy

    2013-12-01

    The treatment of adhesive small bowel obstruction is controversial, with both operative and non-operative management practiced in different centers worldwide. Non-operative management is increasingly getting popular, though operative rates still remain high. A study to compare the efficacy of an oral water-soluble medium (Gastrografin ® ) with standard conservative management, both non-operative methods, in the management of this condition was conducted in a tertiary Sub Saharan hospital. An open randomised controlled clinical trial was conducted between September 2012 and March 2013 at Mulago National Referral and Teaching Hospital, Uganda. Fifty patients of both genders, with adhesive small bowel obstruction, in the hospital's emergency and general surgical wards were included. Randomisation was to Gastrografin ® and standard conservative treatment groups. The primary outcomes were: the time interval between admission and relief of obstruction, the length of hospital stay, and the rates of operative surgery. All 50 recruited patients were followed up and analysed; 25 for each group. In the Gastrografin ® group, 22 (88%) patients had relief of obstruction following the intervention, with 3 (12%) requiring surgery. The conservative treatment group had 16 (64%) patients relieved of obstruction conservatively, and 9 (36%) required surgery. The difference in operative rates between the two groups was not statistically significance ( P = 0.67 ). Average time to relief of obstruction was shorter in the Gastrografin ® group (72.52 hrs) compared to the conservative treatment group (117.75 hrs), a significant difference ( P = 0.023 ). The average length of hospital stay was shorter in the Gastrografin ® group (5.62 days) compared to the conservative treatment group (10.88 days), a significant difference ( P = 0.04 ). The use of Gastrografin ® in patients with adhesive small bowel obstruction helps in earlier resolution of obstruction and reduces the length of hospital stay compared with standard conservative management. Its role in reducing the rate of laparotomies remains inconclusive.

  7. Performance updates of HAWK-I and preparation for the commissioning of the system GRAAL+HAWK-I

    NASA Astrophysics Data System (ADS)

    Hibon, Pascale; Paufique, Jerome; Kuntschner, Harald; Dobrzycka, Danuta; Le Louarn, Miska; Valenti, Elena; Neeser, Mark; Pompei, Emanuela; Arsenault, Robin; Siebenmorgen, Ralf; Madec, Pierre-Yves; Petr-Gotzens, Monika; La Fuente, Carlos; Urrutia, Josefina; Valenzuela, Javier; Castillo, Roberto; Baksai, Pedro; Garcia Dabo, Cesar Enrique; Jost, Andreas; Argomedo, Javier; Kolb, Johann; Kiekebusch, Mario; Hubin, Norbert; Duhoux, Philippe; Conzelmann, Ralf Dieter; Donaldson, Robert; Tordo, Sebastien; Huber, Stefan

    2016-08-01

    The High Acuity Wide field K-band Imager (HAWK-I) instrument is a cryogenic wide field imager operating in the wavelength range 0.9 to 2.5 microns. It has been in operations since 2007 on the UT4 at the Very Large Telescope Observatory in seeing-limited mode. In 2017-2018, GRound Layer Adaptive optics Assisted by Lasers module (GRAAL) will be in operation and the system GRAAL+HAWK-I will be commissioned. It will allow: deeper exposures for nearly point-source objects, or shorter exposure times for reaching the same magnitude, and/or deeper detection limiting magnitude. With GRAAL, HAWK-I will operate more than 80% of the time with an equivalent K-band seeing of 0.55" (instead of 0.7" without GRAAL). GRAAL is already installed and the operations without adaptive optics were commissioned in 2015. We discuss here the latest updates on performance from HAWK-I without Adaptive Optics (AO) and the preparation for the commissioning of the system GRAAL+HAWK-I.

  8. Time Management in the Operating Room: An Analysis of the Dedicated Minimally Invasive Surgery Suite

    PubMed Central

    Hsiao, Kenneth C.; Machaidze, Zurab

    2004-01-01

    Background: Dedicated minimally invasive surgery suites are available that contain specialized equipment to facilitate endoscopic surgery. Laparoscopy performed in a general operating room is hampered by the multitude of additional equipment that must be transported into the room. The objective of this study was to compare the preparation times between procedures performed in traditional operating rooms versus dedicated minimally invasive surgery suites to see whether operating room efficiency is improved in the specialized room. Methods: The records of 50 patients who underwent laparoscopic procedures between September 2000 and April 2002 were retrospectively reviewed. Twenty-three patients underwent surgery in a general operating room and 18 patients in an minimally invasive surgery suite. Nine patients were excluded because of cystoscopic procedures undergone prior to laparoscopy. Various time points were recorded from which various time intervals were derived, such as preanesthesia time, anesthesia induction time, and total preparation time. A 2-tailed, unpaired Student t test was used for statistical analysis. Results: The mean preanesthesia time was significantly faster in the minimally invasive surgery suite (12.2 minutes) compared with that in the traditional operating room (17.8 minutes) (P=0.013). Mean anesthesia induction time in the minimally invasive surgery suite (47.5 minutes) was similar to time in the traditional operating room (45.7 minutes) (P=0.734). The average total preparation time for the minimally invasive surgery suite (59.6 minutes) was not significantly faster than that in the general operating room (63.5 minutes) (P=0.481). Conclusion: The amount of time that elapses between the patient entering the room and anesthesia induction is statically shorter in a dedicated minimally invasive surgery suite. Laparoscopic surgery is performed more efficiently in a dedicated minimally invasive surgery suite versus a traditional operating room. PMID:15554269

  9. Electrical control of a solid-state flying qubit.

    PubMed

    Yamamoto, Michihisa; Takada, Shintaro; Bäuerle, Christopher; Watanabe, Kenta; Wieck, Andreas D; Tarucha, Seigo

    2012-03-18

    Solid-state approaches to quantum information technology are attractive because they are scalable. The coherent transport of quantum information over large distances is a requirement for any practical quantum computer and has been demonstrated by coupling super-conducting qubits to photons. Single electrons have also been transferred between distant quantum dots in times shorter than their spin coherence time. However, until now, there have been no demonstrations of scalable 'flying qubit' architectures-systems in which it is possible to perform quantum operations on qubits while they are being coherently transferred-in solid-state systems. These architectures allow for control over qubit separation and for non-local entanglement, which makes them more amenable to integration and scaling than static qubit approaches. Here, we report the transport and manipulation of qubits over distances of 6 µm within 40 ps, in an Aharonov-Bohm ring connected to two-channel wires that have a tunable tunnel coupling between channels. The flying qubit state is defined by the presence of a travelling electron in either channel of the wire, and can be controlled without a magnetic field. Our device has shorter quantum gates (<1 µm), longer coherence lengths (∼86 µm at 70 mK) and higher operating frequencies (∼100 GHz) than other solid-state implementations of flying qubits.

  10. Laparoscopic extraperitoneal inguinal hernia repair versus open mesh repair: a prospective randomized controlled trial.

    PubMed

    Andersson, Bodil; Hallén, Magnus; Leveau, Per; Bergenfelz, Anders; Westerdahl, Johan

    2003-05-01

    This study was designed to compare an open tension-free technique (Lichtenstein repair) with a laparoscopic totally extraperitoneal hernia repair (TEP). One hundred sixty-eight men aged 30 to 65 years with primary or recurrent inguinal hernia were randomized to TEP or open mesh technique in the manner of Lichtenstein. Follow-up was after 1 and 6 weeks, and 1 year. Eighty-one patients were randomized to TEP, and 87 to open repair. For 1 patient in each group, the operation was converted to a different type of repair. No difference was seen in overall complications between the 2 groups. However, 1 patient in the TEP group underwent operation for small bowel obstruction after surgery. A higher frequency of postoperative hematomas was seen in the open group (P <.05). Patients in the TEP group consumed less analgesic after surgery (P <.001), returned to work earlier (P <.01), and had a shorter time to full recovery (P <.01). Two recurrences occurred in the TEP group 1 year after surgery. The TEP technique was associated with less postoperative pain, a shorter time to full recovery, and an earlier return to work compared with the open tension-free repair. No difference was seen in overall complications. However, 2 recurrences did occur after 1 year in the TEP group.

  11. What is the optimal minimally invasive surgical procedure for endometrial cancer staging in the obese and morbidly obese woman?

    PubMed

    Gehrig, Paola A; Cantrell, Leigh A; Shafer, Aaron; Abaid, Lisa N; Mendivil, Alberto; Boggess, John F

    2008-10-01

    Thirty-three percent of U.S. women are either obese or morbidly obese. This is associated with an increased risk of death from all causes and is also associated with an increased risk of endometrial carcinoma. We sought to compare minimally invasive surgical techniques for staging the obese and morbidly obese woman with endometrial cancer. Consecutive robotic endometrial cancer staging procedures were collected from 2005-2007 and were compared to consecutive laparoscopic cases (2000-2004). Demographics including age, weight, body mass index (BMI), operative time, estimated blood loss, lymph node retrieval, hospital stay and complications were collected and compared. During the study period, there were 36 obese and 13 morbidly obese women who underwent surgery with the DaVinci robotic system and 25 obese and 7 morbidly obese women who underwent traditional laparoscopy. For both the obese and morbidly obese patient, robotic surgery was associated with shorter operative time (p=0.0004), less blood loss (p<0.0001), increased lymph node retrieval (p=0.004) and shorter hospital stay (p=0.0119). Robotic surgery is a useful minimally invasive tool for the comprehensive surgical staging of the obese and morbidly obese woman with endometrial cancer. As this patient population is at increased risk of death from all causes, including post-operative complications, all efforts should be made to improve their outcomes and minimally invasive surgery provides a useful platform by which this can occur.

  12. Patent ductus arteriosus in preterm infants: benefits of early surgical closure.

    PubMed

    Fonseca, Elizabeth; Georgiev, Stanimir G; Gorenflo, Matthias; Loukanov, Tsvetomir S

    2014-05-01

    Patent ductus arteriosus in preterm neonates leads to significant morbidity. Surgery is indicated when pharmacological treatment fails or is contraindicated, but the optimal timing remains unclear. We retrospectively studied all 41 preterm neonates with symptomatic ductus arteriosus who underwent ligation between 1988 and 2009. We compared early complications rates and late neurological outcomes of patients operated on before 21 days of age with these operated on later. The median gestational age at birth was 26 weeks (range 23-31 weeks) and median weight at birth was 930 g (range 510-1500 g); 34 (82.9%) received pharmacological treatment before surgery. Fourteen (34.1%) patients underwent surgical closure before 21 days of age and 27 (65.9%) after 21 days. The 2 groups did not differ significantly in gestational age and weight at birth, but those operated on after 21 days received significantly more pharmacological treatment cycles. Patients in the early closure group had shorter intubation times: median 23 days (range 13-35 days) vs. 43 days (range 27-84 days; p < 0.001) and shorter neonatal intensive care unit stay: median 44 days (range 31-66 days) vs. 76 days (range 41-97 days; p < 0.001), with significantly lower rates of bronchopulmonary dysplasia, intraventricular hemorrhage, and acute renal failure, and significantly better neurological outcomes. Performing early ligation of symptomatic ductus arteriosus after unsuccessful pharmacological therapy in preterm neonates might lower complication rates and improve neurological outcome. Prospective randomized studies are needed to determine the optimal treatment.

  13. Development of a Patient-Based Model for Estimating Operative Times for Robot-Assisted Radical Prostatectomy.

    PubMed

    Huben, Neil; Hussein, Ahmed; May, Paul; Whittum, Michelle; Kraswowki, Collin; Ahmed, Youssef; Jing, Zhe; Khan, Hijab; Kim, Hyung; Schwaab, Thomas; Underwood Iii, Willie; Kauffman, Eric; Mohler, James L; Guru, Khurshid A

    2018-04-10

    To develop a methodology for predicting operative times for robot-assisted radical prostatectomy (RARP) using preoperative patient, disease, procedural and surgeon variables to facilitate operating room (OR) scheduling. The model included preoperative metrics: BMI, ASA score, clinical stage, National Comprehensive Cancer Network (NCCN) risk, prostate weight, nerve-sparing status, extent and laterality of lymph node dissection, and operating surgeon (6 surgeons were included in the study). A binary decision tree was fit using a conditional inference tree method to predict operative times. The variables most associated with operative time were determined using permutation tests. The data was split at the value of the variable that results in the largest difference in means for surgical time across the split. This process was repeated recursively on the resultant data. 1709 RARPs were included. The variable most strongly associated with operative time was the surgeon (surgeons 2 and 4 - 102 minutes shorter than surgeons 1, 3, 5, and 6, p<0.001). Among surgeons 2 and 4, BMI had the strongest association with surgical time (p<0.001). Among patients operated by surgeons 1, 3, 5 and 6, RARP time was again most strongly associated with the surgeon performing RARP. Surgeons 1, 3, and 6 were on average 76 minutes faster than surgeon 5 (p<0.001). The regression tree output in the form of box plots showed operative time median and ranges according to patient, disease, procedural and surgeon metrics. We developed a methodology that can predict operative times for RARP based on patient, disease and surgeon variables. This methodology can be utilized for quality control, facilitate OR scheduling and maximize OR efficiency.

  14. [Results of the Misgav Ladach caesarean section].

    PubMed

    Heidenreich, W; Borgmann, U

    2001-11-01

    At the Department of Obstetrics and Gynecology, Allgemeines Krankenhaus Celle, 224 caesarean sections according to the Misgav Ladach technique were performed from 01. 05. 1998 to 30. 04. 1999. Anamnestic findings, intraoperative conditions, and postoperative course were compared to 125 conventionel caesarean deliveries. The Misgav Ladach technique resulted in notably shorter operative time, fewer complications of wound healing and reduced hospital stay. No further significant differences were observed in both groups. - The question of postoperative adhesions still remains to be answered. According to our experience the Misgav Ladach operation shows some advantages as compared to the usual method.

  15. Reductive stripping process for uranium recovery from organic extracts

    DOEpatents

    Hurst, F.J. Jr.

    1983-06-16

    In the reductive stripping of uranium from an organic extractant in a uranium recovery process, the use of phosphoric acid having a molarity in the range of 8 to 10 increases the efficiency of the reductive stripping and allows the strip step to operate with lower aqueous to organic recycle ratios and shorter retention time in the mixer stages. Under these operating conditions, less solvent is required in the process, and smaller, less expensive process equipment can be utilized. The high strength H/sub 3/PO/sub 4/ is available from the evaporator stage of the process.

  16. Reductive stripping process for uranium recovery from organic extracts

    DOEpatents

    Hurst, Jr., Fred J.

    1985-01-01

    In the reductive stripping of uranium from an organic extractant in a uranium recovery process, the use of phosphoric acid having a molarity in the range of 8 to 10 increases the efficiency of the reductive stripping and allows the strip step to operate with lower aqueous to organic recycle ratios and shorter retention time in the mixer stages. Under these operating conditions, less solvent is required in the process, and smaller, less expensive process equipment can be utilized. The high strength H.sub.3 PO.sub.4 is available from the evaporator stage of the process.

  17. Intraoperative Ultrasound for Peripheral Nerve Applications.

    PubMed

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Robotic surgery in gynecology.

    PubMed

    Magrina, J F

    2007-01-01

    Robotic technology is nothing more than an enhancement along the continuum of laparoscopic technological advances and represents only the beginning of numerous more forthcoming advances. It constitutes a major improvement in the efficiency, accuracy, ease, and comfort associated with the performance of laparoscopic operations. Instrument articulation, downscaling of movements, absence of tremor, 3-D image, and comfort for the surgeon, assistant and scrub nurse are all new to the practice of laparoscopy. In our hands, robotic operative times for simple and radical hysterectomy are shorter than those obtained by conventional laparoscopy. Robotic technology is preferable to conventional laparoscopic instrumentation for the surgical treatment of gynecologic malignancies and most operations for benign disease of certain complexity such as hysterectomy myomectomy, and invasive pelvic endometriosis.

  19. Comparison between Minimally Invasive Transforaminal Lumbar Interbody Fusion and Conventional Open Transforaminal Lumbar Interbody Fusion: An Updated Meta-analysis.

    PubMed

    Xie, Lei; Wu, Wen-Jian; Liang, Yu

    2016-08-20

    The previous studies agree that minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) has better function outcomes, less blood loss, and shorter hospital stay, when compared to open-TLIF. However, there are no significance differences on operative time, complication, and reoperation rate between the two procedures. This could be from less relative literatures and lower grade evidence. The further meta-analysis is needed with more and higher grade evidences to compare the above two TLIF procedures. Prospective and retrospective studies that compared open-TLIF and MIS-TLIF were identified by searching the Medline, Embase, Web of Science, China National Knowledge Infrastructure, Wanfang, and VIP database (the literature search comprised Medical Subject Heading terms and key words or Emtree term). The retrieval time ranged from the date when the database was founded to January 2015. Pooled risk ratios (RR s) and weighted mean differences (WMDs) with 95% confidence intervals were calculated for the clinical outcomes and perioperative data. Twenty-four studies (n = 1967 patients) were included in this review (n = 951, open-TLIF, n = 1016, MIS-TLIF). MIS-TLIF was associated with a significant decrease in the visual analog score (VAS)-back pain score (WMD = -0.44; P = 0.001), Oswestry Disabilities Index (WMD = -1.57; P = 0.005), early ambulation (WMD = -1.77; P = 0.0001), less blood loss (WMD = -265.59; P < 0.00001), and a shorter hospital stay (WMD = -1.89; P < 0.0001). However, there were no significant differences in the fusion rate (RR = 0.99; P = 0.34), VAS-leg pain (WMD = -0.10; P = 0.26), complication rate (RR = 0.84; P = 0.35), operation time (WMD = -5.23; P = 0.82), or reoperation rate (RR = 0.73; P = 0.32). MIS-TLIF resulted in a similar fusion rate with better functional outcome, less blood loss, shorter ambulation, and hospital stay; furthermore, it did not increase the complication or reoperation rate based on the existing evidence.

  20. Laparoendoscopic single-site surgery varicocelectomy versus conventional laparoscopic varicocele ligation: A meta-analysis

    PubMed Central

    Li, Mingchao; Wang, Zhengyun

    2016-01-01

    Objective To perform a meta-analysis of data from available published studies comparing laparoendoscopic single-site surgery varicocelectomy (LESSV) with conventional transperitoneal laparoscopic varicocele ligation. Methods A comprehensive data search was performed in PubMed and Embase to identify randomized controlled trials and comparative studies that compared the two surgical approaches for the treatment of varicoceles. Results Six studies were included in the meta-analysis. LESSV required a significantly longer operative time than conventional laparoscopic varicocelectomy but was associated with significantly less postoperative pain at 6 h and 24 h, a shorter recovery time and greater patient satisfaction with the cosmetic outcome. There was no difference between the two surgical approaches in terms of postoperative semen quality or the incidence of complications. Conclusion These data suggest that LESSV offers a well tolerated and efficient alternative to conventional laparoscopic varicocelectomy, with less pain, a shorter recovery time and better cosmetic satisfaction. Further well-designed studies are required to confirm these findings and update the results of this meta-analysis. PMID:27688686

  1. Adaptation of Timing Behavior to a Regular Change in Criterion

    PubMed Central

    Sanabria, Federico; Oldenburg, Liliana

    2013-01-01

    This study examined how operant behavior adapted to an abrupt but regular change in the timing of reinforcement. Pigeons were trained on a fixed interval (FI) 15-s schedule of reinforcement during half of each experimental session, and on an FI 45-s (Experiment 1), FI 60-s (Experiment 2), or extinction schedule (Experiment 3) during the other half. FI performance was well characterized by a mixture of two gamma-shaped distributions of responses. When a longer FI schedule was in effect in the first half of the session (Experiment 1), a constant interference by the shorter FI was observed. When a shorter FI schedule was in effect in the first half of the session (Experiments 1, 2, and 3), the transition between schedules involved a decline in responding and a progressive rightward shift in the mode of the response distribution initially centered around the short FI. These findings are discussed in terms of the constraints they impose to quantitative models of timing, and in relation to the implications for information-based models of associative learning. PMID:23962672

  2. Tighten water-chemistry control after boiler layup

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brestel, L.

    1994-01-01

    The potential for internal deposition and corrosion can affect boiler reliability by reducing thermal efficiency, tube integrity, and the time between chemical cleanings. While chemical control specifications for normal operation have been developed by consensus of manufacturers and industry, their impact on shutdowns, layups, and startups is not always appreciated. The discussion of chemical-control options applies to boiler systems operating in the medium- and high-pressure ranges. Identification and correction of root causes underlying the chemistry problems encountered and application of the principles involved should result in shorter startup times, improved control over phosphate hideout, and reduced need for chemical cleaning.more » Each of these has a significant cost impact; together, they are the true measure of a successful chemistry-control program.« less

  3. The organizational pendulum--healthcare management in Sweden 1865-1998.

    PubMed

    Axelsson, R

    2000-03-01

    In recent years, there have been a number of large-scale changes in the organization of healthcare in Sweden, as in many other countries. From a longer time perspective, however, there has been a more or less permanent oscillation between centralization and decentralization, and also between competition and co-operation, in Swedish healthcare organizations. In fact, there seems to be something like a pendulum moving all the time between opposite forms of organization. The frequency of these changes has been increasing during the last fifteen years, as different organizational models have replaced each other at shorter and shorter intervals. This development is partly due to the increasing rate of change in modern society, but partly also due to an element of fashion in the area of management. There is, however, a growing change fatigue in many healthcare organizations, and also increasing demands for empirical evidence on the efficiency and effectiveness of different organizational models before they are introduced into the healthcare system.

  4. Sutureless circumcision using 2-Octyl cyanoacrylate results in more rapid and less painful procedures with excellent cosmetic satisfaction.

    PubMed

    Van Haute, C; Tailly, T; Klockaerts, K; Ringoir, Y

    2015-06-01

    Circumcision is the most common surgical procedure in male children in the world and is performed because of cultural, religious or medical reasons. Traditionally, interrupted sutures are used to close the wound, but 2-Octyl cyanoacrylate (2-OCA) tissue glue can be used as an alternative method to close the circumcision wound. To compare the use of 2-OCA with absorbable sutures in circumcision wound closure in prepubescent patients in terms of operative time, complication rate, postoperative pain and cosmetic results. We retrospectively evaluated 662 circumcision procedures using sutures and 609 procedures using 2-OCA for wound closure in prepubescent boys. All circumcision procedures were performed by 2 surgeons in a single centre. Operative time was collected from the hospital surgical software system. 62% of the patients in the suture group and 59% of the patients in the 2-OCA group presented for a postoperative check-up 6 weeks after the circumcision. Data regarding postoperative pain, need for analgesia, cosmetic satisfaction and the ease of wound care were collected through questionnaires completed by 25% of the boy's parents in the suture group and 53% of the parents in the 2-OCA group. Mean operative time was significantly shorter in the 2-OCA group (13 min) than in the suture group (17 min). Complications were comparable and mostly minor. Reintervention was only required in 3 cases. According to the parents, the degree of postoperative pain and the postoperative need for analgesics was significantly lower in the 2-OCA group. Wounds closed with 2-OCA were easier to care for. The cosmetic results after 1 day, after 1 week and after 1 month in the 2-OCA group were significantly superior than in the suture group, according to the parents' evaluation. The use of 2-OCA in circumcision wound closure has been reported before. Previous studies with mainly limited patient numbers report less pain, shorter procedure times and a higher surgeon satisfaction in terms of cosmetic results. This study is the largest study comparing the use of 2-OCA and interrupted sutures in circumcision wound closure. The retrospective character of the study, the lack of a validated questionnaire tool for the cosmetic evaluation and the use of the parent's evaluation are the limitations of this study. The use of 2-OCA in circumcision wound closure results in a shorter operative time, in less postoperative pain, in easy postoperative wound care and in excellent cosmesis when compared to interrupted absorbable sutures. 2-OCA is our current technique of choice in circumcision wound closure. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  5. Diode laser assisted minimal invasive sphenoidotomy for endoscopic transphenoidal pituitary surgery: our technique and results.

    PubMed

    Lee, Jih-Chin; Lai, Wen-Sen; Ju, Da-Tong; Chu, Yueng-Hsiang; Yang, Jinn-Moon

    2015-03-01

    During endoscopic sinus surgery (ESS), intra-operative bleeding can significantly compromise visualization of the surgical field. The diode laser that provides good hemostatic and vaporization effects and excellent photocoagulation has been successfully applied in endoscopic surgery with several advantages. The current retrospective study demonstrates the feasibility of diode laser-combined endoscopic sinus surgery on sphenoidotomy. The patients who went through endoscopic transphenoidal pituitary surgery were enrolled. During the operation, the quality of the surgical field was assessed and graded by the operating surgeon using the scale proposed by Boezaart. The mean operation time was 37.80 ± 10.90 minutes. The mean score on the quality of surgical field was 1.95. A positive correlation between the lower surgical field quality score and the shorter surgical time was found with statistical significance (P < 0.0001). No infections, hemorrhages, or other complications occurred intra- or post-operatively. The diode laser-assisted sphenoidotomy is a reliable and safe approach of pituitary gland surgery with minimal invasiveness. It is found that application of diode laser significantly improved quality of surgical field and shortened operation time. © 2015 Wiley Periodicals, Inc.

  6. Health and Safety Benefits of Small Pressurized Suitport Rovers as EVA Surface Support Vehicles

    NASA Technical Reports Server (NTRS)

    Gernhardt, Michael L.; Abercromby, Andrew F. J.

    2008-01-01

    Pressurized safe-haven providing SPE protection and decompression sickness (DCS) treatment capabilities within 20 mins at all times. Up to 50% reduction in time spent in EVA suits (vs. Unpressurized Rovers) for equal or greater Boots-on-Surface EVA exploration time. Reduces suit-induced trauma and provides improved options for nutrition, hydration, and waste-management. Time spent inside SPR during long translations may be spent performing resistive and cardiovascular exercise. Multiple shorter EVAs versus single 8 hr EVAs increases DCS safety and decreases prebreathe requirements. SPRs also offer many potential operational, engineering and exploration benefits not addressed here.

  7. Statistical process control as a tool for controlling operating room performance: retrospective analysis and benchmarking.

    PubMed

    Chen, Tsung-Tai; Chang, Yun-Jau; Ku, Shei-Ling; Chung, Kuo-Piao

    2010-10-01

    There is much research using statistical process control (SPC) to monitor surgical performance, including comparisons among groups to detect small process shifts, but few of these studies have included a stabilization process. This study aimed to analyse the performance of surgeons in operating room (OR) and set a benchmark by SPC after stabilized process. The OR profile of 499 patients who underwent laparoscopic cholecystectomy performed by 16 surgeons at a tertiary hospital in Taiwan during 2005 and 2006 were recorded. SPC was applied to analyse operative and non-operative times using the following five steps: first, the times were divided into two segments; second, they were normalized; third, they were evaluated as individual processes; fourth, the ARL(0) was calculated;, and fifth, the different groups (surgeons) were compared. Outliers were excluded to ensure stability for each group and to facilitate inter-group comparison. The results showed that in the stabilized process, only one surgeon exhibited a significantly shorter total process time (including operative time and non-operative time). In this study, we use five steps to demonstrate how to control surgical and non-surgical time in phase I. There are some measures that can be taken to prevent skew and instability in the process. Also, using SPC, one surgeon can be shown to be a real benchmark. © 2010 Blackwell Publishing Ltd.

  8. Totally laparoscopic radical BII gastrectomy for the treatment of gastric cancer: a comparison with open surgery.

    PubMed

    Lee, Wei-Jei; Wang, Weu; Chen, Tai-Chi; Chen, Jung-Chieh; Ser, Kong-Han

    2008-08-01

    Laparoscopically assisted distal gastrectomy has been used for distal part early gastric cancer resection. However, use of totally laparoscopic gastric cancer resection remains limited because of technical problems, especially when standard D2 nodal dissection was applied. We had reported the first totally laparoscopic Billroth II (BII) subtotal gastrectomy with lymphadenectomy for early gastric cancer in the year 1998. The aim of this study is to determine whether this procedure is superior to conventional open technique. The clinical course of 34 consecutive patients who underwent totally laparoscopic BII gastrectomy using an upper to lower, right to left, and clockwise quadrant-to-quadrant technique was compared with 34 sex-matched and age-matched patients who underwent open gastrectomy. Main outcome measures included operative time, blood loss, length of stay, morbidity and mortality, adequacy of lymphadenectomy, and long-term outcome. In the laparoscopic group, all the operations were completed by laparoscopic technique, but 1 patient required secondary laparotomy for total gastrectomy owing to inadequate resection margin. There was no operation mortality in this study. The postoperative complication rates were similar in these 2 groups. The mean operative time for laparoscopic group was 283+/-122 minutes (range: 186 to 480 min), significantly longer than the 195+/-26 minutes in the conventional group (P<0.001). Laparoscopic group was associated with less intraoperative blood loss (74 vs. 190 mL; P<0.01), early flatus passage (2.9 vs. 4.9 d; P<0.01), less usage of analgesics (3.5 vs. 5.8 doses; P<0.05), and a shorter postoperative hospital stay (8.5 vs. 12.1 d; P<0.01). There was no significant difference between laparoscopic and conventional open radical gastrectomy with regard to ratio of free margin, number of harvested lymph nodes, and survival. Although totally laparoscopic BII gastrectomy using the upper to lower technique required a longer surgical time and was technically more demanding than conventional open surgery, it resulted in shorter recovery time, less analgesic use, and less severe physical discomfort without compromising the operative curability and oncologic outcomes.

  9. Evaluation of timings and outcomes in category-one caesarean sections: A retrospective cohort study

    PubMed Central

    Dunn, Clare Newton; Zhang, Qianpian; Sia, Josh Tjunrong; Assam, Pryseley Nkouibert; Tagore, Shephali; Sng, Ban Leong

    2016-01-01

    Background and Aims: A decision-to-delivery interval (DDI) of 30 min for category-one caesarean section (CS) deliveries is the standard of practice recommended by clinical guidelines. Our institution established a protocol for category-one (‘crash’) CS to expedite deliveries. The aim of this study is to evaluate DDI, factors that affect DDI and the mode of anaesthesia for category-one CS. Methods: This retrospective cohort study evaluated 390 women who underwent category-one CS in a tertiary obstetric centre. We analysed the factors associated with DDI, mode of anaesthesia and perinatal outcomes. Summary statistics were performed for the outcomes. The association factors were considered significant at P < 0.05. Results: The mean (standard deviation) DDI was 9.4 (3.2) min with all deliveries achieved within 30 min. The longest factor in the DDI was time taken to transfer patients. A shorter DDI was not significantly associated with improved perinatal outcomes. The majority (88.9%) of women had general anaesthesia (GA) for category-one CS. Of those who had an epidural catheter already in situ (34.4%), 25.6% had successful epidural extension. GA was associated with shorter DDI, but worse perinatal outcomes than regional anaesthesia (RA). Conclusions: Our ‘crash’ CS protocol achieved 100% of deliveries within 30 min. The majority (88.9%) of the patients had GA for category-one CS. GA was found to be associated with shorter anaesthesia and operation times, but poorer perinatal outcomes compared to RA. PMID:27601736

  10. Comparative study of Misgav-Ladach and Pfannenstiel-Kerr cesarean techniques: a randomized controlled trial.

    PubMed

    Naki, Mehmet Murat; Api, Oluş; Celik, Hasniye; Kars, Bülent; Yaşar, Esra; Unal, Orhan

    2011-02-01

    To compare Pfannenstiel-Kerr (PKM) and Misgav-Ladach (MLM) methods in terms of operation-related features and neonatal outcome in primary cesarean deliveries. A total of 180 pregnant women randomized into PKM (n = 90) or MLM (n = 90) groups were included in this study. Primary outcome measures were total operative and extraction times, Apgar score, blood loss, wound complications, and the suture use. Secondary outcome measures were wound seroma and infection incidence, time of bowel restitution, and the perceived pain. Total operation and extraction times were significantly shorter and less suture material was used in the MLM group than the PKM group (p < 0.001). Initially, higher scores obtained for 6 h-VAS in the MLM group (p < 0.05) were normalized after 24 h of the operation. PKM and MLM were similar in terms of preoperative and postoperative levels of hemoglobin and hematocrit, wound complication, bowel restitution, fever, seroma, infection, wound dehiscence and the need for transfusion, antibiotic, and analgesics. The operation-related morbidity of the MLM and PKM for primary C/S seem to be comparable; however, the MLM seems to be superior in terms of operation time and the amount of suture usage but inferior in pain scores in the early postoperative period.

  11. Plantar Pressure Anomalies After Open Reduction With Internal Fixation of High-Grade Calcaneal Fractures.

    PubMed

    Hetsroni, Iftach; Ben-Sira, David; Nyska, Meir; Ayalon, Moshe

    2014-07-01

    Plantar pressure abnormalities after open reduction with internal fixation (ORIF) of intra-articular calcaneal fractures have been observed previously, but high-grade fractures were not selectively investigated and follow-up times were shorter than 2 years. The purpose of this study was to characterize plantar pressure anomalies in patients with exclusively high-grade calcaneal fractures after ORIF with a minimum 2 years of follow-up, and to test the association between plantar pressure distribution and the clinical outcome. The orthopaedic registry was reviewed to identify patients with isolated high-grade calcaneal fractures (Sanders types III-IV) who were operated on and had a minimum 2 years of follow-up. Sixteen patients were evaluated. Mean age was 47 years and follow-up was between 2 and 6 years. The Pedar-Mobile system was used to measure 3 loading and 3 temporal variables and compare these between the operated and the uninjured limbs. Mean American Orthopaedic Foot and Ankle Society (AOFAS) score was 76 ± 7 at latest follow-up. Bohler's angle was 5 ± 8 degrees before surgery and 25 ± 7 degrees at latest follow-up. Stance was shorter in operated limbs (P = .001). Timing of the peak of pressure was delayed in operated limbs under the hallux and the second toe (P ≤ .03). Peak pressure, force time integral, and pressure time integral were increased under the lateral midfoot (P ≤ .03) and decreased under the second metatarsal (P ≤ .03). Force time integral was decreased under the first metatarsal (P = .02) and under the hallux and the lateral toes (P ≤ .05). Increased loading under the lateral midfoot and decreased loading under the lateral toes were correlated with poorer clinical outcome (r = -.53, P < .05, and r = .63, P < .01, respectively). Side-to-side plantar pressure mismatch persisted at more than 2 years after ORIF of high-grade calcaneal fractures performed via lateral approach, despite improvement of Bohler's angle. This was characterized by shortened stance phase, delayed timing of peak of pressure under the hallux and second toe, lateral load shift at the midfoot, and decreased toe pressures in operated limbs. Since loading abnormalities were correlated with the clinical outcome, modifications in treatment strategy that can improve foot loading may be desirable in these cases. Level III, case control. © The Author(s) 2014.

  12. [Reconstruction in plastic surgery using osmotic tissue expanders].

    PubMed

    Gronovich, Yoav; Binenboym, Rami; Retchkiman, Meir; Eizenman, Nirit; Lotan, Adi; Stuchiner, Barak; Tuchman, Izhak

    2015-03-01

    Tissue expander is a major reconstructive modality. Its main disadvantages include: long and inconvenient period of inflation with temporary deformity of the surrounding tissue. Osmotic expander was developed in order to eliminate some of these limitations. It is a self-filling device which absorbs fluids in order to achieve tissue expansion faster. We present our experience with 28 consecutive cases of tissue reconstruction using osmotic expanders. We wish to emphasize the main advantages and limitations of this device. The present study was launched in May 2008, until April 2014, for twenty eight patients, median age 26 years with reconstructions using an osmotic expander (total of 35 expanders). The reasons for using tissue expander included large congenital nevi (75%) and scars. In all of the cases, the operative and post-operative management was uneventful. During the expansion period, there were 2 outpatient clinical visits. The average expansion time was 9 weeks. In 11% (three patients) there was partial extrusion of the expander. In all other cases there were no complications and the final aesthetic results were satisfying. Osmotic expander is an advanced modality for tissue reconstruction. The final shape and size are precisely predictable. Its initial small size allows for a small surgical incision and short overall operating time. The expansion period is shorter and more convenient for the patient. Its main disadvantage includes the inability to control the filling rate and the need to remove the expander in case of damage to the overlying tissue. Osmotic expander is a reliable tool for tissue expansion. It allows for a satisfying aesthetic result in a shorter period of time and with less inconvenience to the patient.

  13. Implementation of enhanced recovery programme for laparoscopic distal pancreatectomy: feasibility, safety and cost analysis.

    PubMed

    Richardson, John; Di Fabio, Francesco; Clarke, Hannah; Bajalan, Mohammed; Davids, Joe; Abu Hilal, Mohammed

    2015-01-01

    The adoption of laparoscopy for distal pancreatectomy has proven to substantially improve short-term outcomes. Stress response after major surgery can be further minimized within an enhanced recovery programme (ERP). However, data on the potential benefit of an ERP for laparoscopic distal pancreatectomy are still lacking. The aim was to assess the feasibility, safety and cost of ERP for patients undergoing laparoscopic distal pancreatectomy. This is a case-control study from a Tertiary University Hospital. Sixty-six consecutive patients who underwent laparoscopic distal pancreatectomy were analyzed. Twenty-two patients were enrolled for the ERP and compared with previous consecutive 44 patients managed traditionally (1:2 ratio). Operative details, post-operative outcome and cost analysis were compared in the two groups. Patients enrolled in the ERP had similar intraoperative blood loss (median 165 ml vs. 200 ml; p = 0.176), operation time (225 min vs. 210 min; p = 0.633), time to remove naso-gastric tube (1 vs. 1 day; p = 0.081) but significantly shorter time to mobilization (median 1 vs. 2 days; p = 0.0001), start solid diet (2 vs. 3 days; p = 0004), and pass stools (3 vs. 5 days; p = 0.002) compared to the control group. Median length of stay was significantly shorter in the ERP group (3 vs. 6 days; p < 0.0001). No significant difference in readmission or complication rate was observed. Cost analysis was significantly in favor of the ERP group (p = 0.0004). Implementation of ERP optimizes outcomes for laparoscopic distal pancreatectomy with significant earlier return to normal gut function, reduced length of stay and cost saving. Copyright © 2015 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  14. Using methylene blue as a marker to find and remove tiny metallic foreign bodies embedded in the soft tissues of children: A randomised controlled trial.

    PubMed

    Su, Yuxi; Nan, Guoxin

    2016-05-01

    Embedment of metallic foreign bodies in the soft tissues is commonly encountered in the emergency room. Most foreign bodies are easily removed, but removal is difficult if the foreign body is very small or deeply embedded. To determine the usefulness of methylene blue staining in the surgical removal of tiny metallic foreign bodies embedded in the soft tissue. This prospective study involved 41 children treated between May 2007 and May 2012. The patients were randomly divided into a methylene blue group and a control group. In the control group, foreign bodies were located using a C-arm and removed via direct incision. In the methylene blue group, foreign bodies were located using a C-arm, marked with an injection of methylene blue and then removed surgically. The clinical outcomes, complications, operation time, surgical success rate, incision length, frequency of C-arm use, and length and depth of the foreign body were compared between the two groups. The surgical success rate was significantly higher in the methylene blue group. The average operation time was significantly shorter in the methylene blue group. The C-arm was used significantly less frequently in the methylene blue group than in the control group. The incision length was significantly shorter in the methylene blue group than in the control group. Methylene blue staining facilitated the location and removal of tiny metallic foreign bodies from the soft tissue, and significantly reduced operation time, incision length and radiation exposure compared to the conventional method. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  15. Transverse pinning versus intramedullary pinning in fifth metacarpal's neck fractures: A randomized controlled study with patient-reported outcome.

    PubMed

    Galal, Sherif; Safwat, Wael

    2017-01-01

    The 5th metacarpal fractures accounts for 38% of all hand fractures given that the neck is the weakest point in metacarpals, so neck fracture is the most common metacarpal fracture. Surgical fixation is also advocated for such fractures to prevent mal-rotation of the little finger which will lead to fingers overlap in a clenched fist. Various methods are available for fixation of such fractures, like intramedullary & transverse pinning. There are very few reports in the literature comparing both techniques. Authors wanted to compare outcomes and complications of transverse pinning versus intramedullary pinning in fifth metacarpal's neck fractures. A single-center, parallel group, prospective, randomized study was conducted at an academic Level 1 Trauma Center from October 2014 to December 2016. A total of 80 patients with 5th metacarpal's neck fractures were randomized to pinning using either transverse pinning (group A) or intramedullary pinning (group B). Patients were assessed clinically on range of motion, patient-reported outcome using the Quick-DASH (Disabilities of the Arm, Shoulder, and Hand) questionnaire & radiographically. Two blinded observers assessed outcomes. At final follow up for each patient (12 months) the statistically significant differences were observed in operative time, the transverse pinning group showed shorter operative time, as well as complication rate as complications were observed only in intramedullary pinning group. No differences were found in range of motion or the Quick -DASH score. Both techniques are equally safe and effective treatment option for 5th metacarpal's neck fractures. The only difference was shorter operative time & less incidence of complications in transverse pinning group. Level II, Therapeutic study.

  16. The role of ultrasound guidance in pediatric caudal block

    PubMed Central

    Erbüyün, Koray; Açıkgöz, Barış; Ok, Gülay; Yılmaz, Ömer; Temeltaş, Gökhan; Tekin, İdil; Tok, Demet

    2016-01-01

    Objectives: To compare the time interval of the procedure, possible complications, post-operative pain levels, additional analgesics, and nurse satisfaction in ultrasonography-guided and standard caudal block applications. Methods: This retrospective study was conducted in Celal Bayar University Hospital, Manisa, Turkey, between January and December 2014, included 78 pediatric patients. Caudal block was applied to 2 different groups; one with ultrasound guide, and the other using the standard method. Results: The time interval of the procedure was significantly shorter in the standard application group compared with ultrasound-guided group (p=0.020). Wong-Baker FACES Pain Rating Scale values obtained at the 90th minute was statistically lower in the standard application group compared with ultrasound-guided group (p=0.035). No statistically significant difference was found on the other parameters between the 2 groups. The shorter time interval of the procedure at standard application group should not be considered as a distinctive mark by the pediatric anesthesiologists, because this time difference was as short as seconds. Conclusion: Ultrasound guidance for caudal block applications would neither increase nor decrease the success of the treatment. However, ultrasound guidance should be needed in cases where the detection of sacral anatomy is difficult, especially by palpations. PMID:26837396

  17. Interoperative efficiency in minimally invasive surgery suites.

    PubMed

    van Det, M J; Meijerink, W J H J; Hoff, C; Pierie, J P E N

    2009-10-01

    Performing minimally invasive surgery (MIS) in a conventional operating room (OR) requires additional specialized equipment otherwise stored outside the OR. Before the procedure, the OR team must collect, prepare, and connect the equipment, then take it away afterward. These extra tasks pose a thread to OR efficiency and may lengthen turnover times. The dedicated MIS suite has permanently installed laparoscopic equipment that is operational on demand. This study presents two experiments that quantify the superior efficiency of the MIS suite in the interoperative period. Preoperative setup and postoperative breakdown times in the conventional OR and the MIS suite in an experimental setting and in daily practice were analyzed. In the experimental setting, randomly chosen OR teams simulated the setup and breakdown for a standard laparoscopic cholecystectomy (LC) and a complex laparoscopic sigmoid resection (LS). In the clinical setting, the interoperative period for 66 LCs randomly assigned to the conventional OR or the MIS suite were analyzed. In the experimental setting, the setup and breakdown times were significantly shorter in the MIS suite. The difference between the two types of OR increased for the complex procedure: 2:41 min for the LC (p < 0.001) and 10:47 min for the LS (p < 0.001). In the clinical setting, the setup and breakdown times as a whole were not reduced in the MIS suite. Laparoscopic setup and breakdown times were significantly shorter in the MIS suite (mean difference, 5:39 min; p < 0.001). Efficiency during the interoperative period is significantly improved in the MIS suite. The OR nurses' tasks are relieved, which may reduce mental and physical workload and improve job satisfaction and patient safety. Due to simultaneous tasks of other disciplines, an overall turnover time reduction could not be achieved.

  18. Retroperitoneal versus transperitoneal robotic-assisted laparoscopic partial nephrectomy: a matched-pair, bicenter analysis with cost comparison using time-driven activity-based costing.

    PubMed

    Laviana, Aaron A; Tan, Hung-Jui; Hu, Jim C; Weizer, Alon Z; Chang, Sam S; Barocas, Daniel A

    2018-03-01

    To perform a bicenter, retrospective study of perioperative outcomes of retroperitoneal versus transperitoneal robotic-assisted laparoscopic partial nephrectomy (RALPN) and assess costs using time-driven activity-based costing (TDABC). We identified 355 consecutive patients who underwent RALPN at University of California Los Angeles and the University of Michigan during 2009-2016. We matched according to RENAL nephrometry score, date, and institution for 78 retroperitoneal versus 78 transperitoneal RALPN. Unadjusted analyses were performed using McNemar's Chi-squared or paired t test, and adjusted analyses were performed using multivariable repeated measures regression analysis. From multivariable models, predicted probabilities were derived according to approach. Cost analysis was performed using TDABC. Patients treated with retroperitoneal versus transperitoneal RALPN were similar in age (P = 0.490), sex (P = 0.715), BMI (P = 0.273), and comorbidity (P = 0.393). Most tumors were posterior or lateral in both the retroperitoneal (92.3%) and transperitoneal (85.9%) groups. Retroperitoneal RALPN was associated with shorter operative times (167.0 versus 191.1 min, P = 0.001) and length of stay (LOS) (1.8 versus 2.7 days, P < 0.001). There were no differences in renal function preservation or cancer control. In adjusted analyses, retroperitoneal RALPN was 17.6-min shorter (P < 0.001) and had a 76% lower probability of LOS at least 2 days (P < 0.001). Utilizing TDABC, transperitoneal RALPN added $2337 in cost when factoring in disposable equipment, operative time, LOS, and personnel. In two high-volume, tertiary centers, retroperitoneal RALPN is associated with reduced operative times and shortened LOS in posterior and lateral tumors, whereas sharing similar clinicopathologic outcomes, which may translate into lower healthcare costs. Further investigation into anterior tumors is needed.

  19. Development of an image operation system with a motion sensor in dental radiology.

    PubMed

    Sato, Mitsuru; Ogura, Toshihiro; Yasumoto, Yoshiaki; Kadowaki, Yuta; Hayashi, Norio; Doi, Kunio

    2015-07-01

    During examinations and/or treatment, a dentist in the examination room needs to view images with a proper display system. However, they cannot operate the image display system by hands, because dentists always wear gloves to be kept their hands away from unsanitized materials. Therefore, we developed a new image operating system that uses a motion sensor. We used the Leap motion sensor technique to read the hand movements of a dentist. We programmed the system using C++ to enable various movements of the display system, i.e., click, double click, drag, and drop. Thus, dentists with their gloves on in the examination room can control dental and panoramic images on the image display system intuitively and quickly with movement of their hands only. We investigated the time required with the conventional method using a mouse and with the new method using the finger operation. The average operation time with the finger method was significantly shorter than that with the mouse method. This motion sensor method, with appropriate training for finger movements, can provide a better operating performance than the conventional mouse method.

  20. Laparoscopic Nissen fundoplication for gastro-oesophageal reflux disease in infants.

    PubMed

    Leung, Ling; Wong, Carol Wing Yan; Chung, Patrick Ho Yu; Wong, Kenneth Kak Yuen; Tam, Paul Kwong Hang

    2015-01-01

    Data on laparoscopic Nissen fundoplication for gastro-oesophageal reflux disease (GERD) in infants remain limited. We describe our experience with this operation in children and in particular, infants younger than 12 months old. Medical records of all paediatric patients who had laparoscopic fundoplication done for GERD from 1998 to 2013 were reviewed. Patients were divided into two groups based on age: group I: 0-12 months, and group II >12 months. Data on indications, patient's demographics, operative time, blood loss, conversions, complications, recurrences and duration of hospitalization were studied. A total of 86 patients were reviewed (group I, n = 21; group II, n = 65). While the mean age and body weight for group I were 8 ± 2.99 months and 6 ± 1.96 kg, the values for group II were 98 ± 65 months and 18 ± 9.6 kg, respectively. All patients had concurrent laparoscopic gastrostomy for feeding difficulties. The mean operative time was shorter in group I (157 ± 55 vs 169 ± 52 min, p = 0.66). Both groups had minimal blood loss only. The surgical outcomes in both groups were comparable in terms of recurrence (0 vs 3 %, p = 0.105) and complications (9.5 vs 6 %, p = 0.275). The median follow-up duration for group I and group II was 23 and 40 months, respectively. Sixteen (76 %) patients in group I and 45 (67 %) patients in group II did not develop pneumonia post fundoplication. Laparoscopic Nissen fundoplication can be safely performed in infants with outcomes comparable to older patients and a shorter operative duration. Low recurrence rate (up to 3 %) is shown by our long term follow-up data. We recommend laparoscopic Nissen fundoplication to be considered in managing infants with GERD.

  1. Effect of operating conditions on performance of silica gel-water air-fluidised desiccant cooler

    NASA Astrophysics Data System (ADS)

    Rogala, Zbigniew; Kolasiński, Piotr; Gnutek, Zbigniew

    2017-11-01

    Fluidised desiccant cooling is reported in the literature as an efficient way to provide cooling for air-conditioning purposes. The performance of this technology can be described by electric and thermal Coefficients of Performance (COP) and Specific Cooling Power (SCP). In this paper comprehensive theoretical study was carried out in order to assess the effect of operating conditions such as: superficial air velocity, desiccant particle diameter, bed switching time and desiccant filling height on the performance of fluidised desiccant cooler (FDC). It was concluded that FDC should be filled with as small as possible desiccant particles featuring diameters and should not be operated with shorter switching times than optimum. Moreover in order to efficiently run such systems superficial air velocities during adsorption and desorption should be similar. At last substantial effect of desiccant filling height on performance of FDC was presented.

  2. Cesarean techniques in cases with one previous cesarean delivery: comparison of modified Misgav-Ladach and Pfannenstiel-Kerr.

    PubMed

    Gedikbasi, Ali; Akyol, Alpaslan; Ulker, Volkan; Yildirim, Dogukan; Arslan, Oguz; Karaman, Erbil; Ceylan, Yavuz

    2011-04-01

    To compare the effectiveness of the Pfannenstiel-Kerr method (PKM) or modified Misgav-Ladach method (MMLM) in previous cesarean sections (C/Ss). Hundred and fifteen gravidas were included with previous one C/S, using either a PKM or MMLM. Demographic characteristics, operative outcomes, surgical complications, and neonatal outcomes were compared in two groups. The mean operative time (18.0 ± 3.5 vs. 23.5 ± 5.7 min; p < 0.0001) and mean extraction time (90.1 ± 41.2 vs. 208.1 ± 79.1 s; p < 0.0001) were significantly shorter in the MMLM group than the PKM group. Postoperative recovery (mobilization, normalization of bowel function, need for analgesics, time to oral feeding, and intra-operative blood loss) was similar between the MMLM and PKM groups. The MMLM appears to be a faster alternative to PKM for previous C/Ss, with similar results as in previous studies with primary CSs.

  3. Non-extracorporeal circulation for coronary artery bypass graft surgery is more beneficial than extracorporeal circulation.

    PubMed

    Yang, F-Y; Bao, Y-Z; Liu, F-S; Zhu, Y-C; Zheng, J; Zhang, J-H; Zheng, X-F; Wei, G-C

    2015-04-01

    The objective of this study was to compare coronary artery bypass graft (CABG) surgery with non-extracorporeal vs. extracorporeal circulation. The study outcomes included operative time, number of graft vessels, pulmonary infection rates, and systemic inflammatory markers. 96 patients received selective CABG, either with non-extracorporeal (study group; n = 48) or extracorporeal circulation (control group; n = 48). Operative time, pulmonary infection rates, and blood levels of inflammatory markers TNF-α, IL-6, and IL-8 before and 4, 24, and 48 hours after the surgery were quantified. Graft vessels were quantified using computed tomography. Operative time was significantly shorter in study group (4.58 ± 0.91 vs. 5.36 ± 1.12 hours in control group; p < 0.05). The number of graft vessels and pulmonary infection rates were comparable between both techniques. However, systemic inflammatory markers were significantly (p < 0.05) lower in study group at 4 and, partly, 24 hours after the surgery. Extracorporeal circulation prolongs operation and can aggravate systemic inflammatory response. Therefore, CABG with non-extracorporeal circulation offers more beneficial outcomes.

  4. Comparative Study of Hand-Sutured versus Circular Stapled Anastomosis for Gastrojejunostomy in Laparoscopy Assisted Distal Gastrectomy.

    PubMed

    Seo, Su Hyun; Kim, Ki Han; Kim, Min Chan; Choi, Hong Jo; Jung, Ghap Joong

    2012-06-01

    Mechanical stapler is regarded as a good alternative to the hand sewing technique, when used in gastric reconstruction. The circular stapling method has been widely applied to gastrectomy (open orlaparoscopic), for gastric cancer. We illustrated and compared the hand-sutured method to the circular stapling method, for Billroth-II, in patients who underwent laparoscopy assisted distal gastrectomy for gastric cancer. Between April 2009 and May 2011, 60 patients who underwent laparoscopy assisted distal gastrectomy, with Billroth-II, were enrolled. Hand-sutured Billroth-II was performed in 40 patients (manual group) and circular stapler Billroth-II was performed in 20 patients (stapler group). Clinicopathological features and post-operative outcomes were evaluated and compared between the two groups. Nosignificant differences were observed in clinicopathologic parameters and post-operative outcomes, except in the operation times. Operation times and anastomosis times were significantly shorter in the stapler group (P=0.004 and P<0.001). Compared to the hand-sutured method, the circular stapling method can be applied safely and more efficiently, when performing Billroth-II anastomosis, after laparoscopy assisted distal gastrectomy in patients with gastric cancer.

  5. Transoral robotic surgery for the base of tongue squamous cell carcinoma: a preliminary comparison between da Vinci Xi and Si.

    PubMed

    Alessandrini, Marco; Pavone, Isabella; Micarelli, Alessandro; Caporale, Claudio

    2017-09-13

    Considering the emerging advantages related to da Vinci Xi robotic platform, the aim of this study is to compare for the first time the operative outcomes of this tool to the previous da Vinci Si during transoral robotic surgery (TORS), both performed for squamous cell carcinomas (SCC) of the base of tongue (BOT). Intra- and peri-operative outcomes of eight patients with early stage (T1-T2) of the BOT carcinoma and undergoing TORS by means of the da Vinci Xi robotic platform (Xi-TORS) are compared with the da Vinci Si group ones (Si-TORS). With respect to Si-TORS group, Xi-TORS group demonstrated a significantly shorter overall operative time, console time, and intraoperative blood loss, as well as peri-operative pain intensity and length of mean hospital stays and nasogastric tube positioning. Considering recent advantages offered by surgical robotic techniques, the da Vinci Xi Surgical System preliminary outcomes could suggest its possible future routine implementation in BOT squamous cell carcinoma procedures.

  6. [Significance of three-dimensional reconstruction as a method of preoperative planning of laparoscopic radiofrequency ablation].

    PubMed

    Zhang, W W; Wang, H G; Shi, X J; Chen, M Y; Lu, S C

    2016-09-01

    To discuss the significance of three-dimensional reconstruction as a method of preoperative planning of laparoscopic radiofrequency ablation(LRFA). Thirty-two cases of LRFA admitted from January 2014 to December 2015 in Department of Hepatobiliary Surgery, Chinese People's Liberation Army General Hospital were analyzed(3D-LRFA group). Three-dimensional(3D) reconstruction were taken as a method of preoperative planning in 3D-LRFA group.Other 64 LRFA cases were paired over the same period without three-dimensional reconstruction before the operation (LRFA group). Hepatobiliary system contrast enhanced CT scan of 3D-RFA patients were taken by multi-slice spiral computed tomography(MSCT), and the DICOM data were processed by IQQA(®)-Liver and IQQA(®)-guide to make 3D reconstruction.Using 3D reconstruction model, diameter and scope of tumor were measured, suitable size (length and radiofrequency length) and number of RFA electrode were chosen, scope and effect of radiofrequency were simulated, reasonable needle track(s) was planed, position and angle of laparoscopic ultrasound (LUS) probe was designed and LUS image was simulated.Data of operation and recovery were collected and analyzed. Data between two sets of measurement data were compared with t test or rank sum test, and count data with χ(2) test or Fisher exact probability test.Tumor recurrence rate was analyzed with the Kaplan-Meier survival curve and Log-rank (Mantel-Cox) test. Compared with LRFA group ((216.8±66.2) minutes, (389.1±183.4) s), 3D-LRFA group ((173.3±59.4) minutes, (242.2±90.8) s) has shorter operation time(t=-3.138, P=0.002) and shorter mean puncture time(t=-2.340, P=0.021). There was no significant difference of blood loss(P=0.170), ablation rate (P=0.871) and incidence of complications(P=1.000). Compared with LRFA group ((6.3±3.9)days, (330±102)U/L, (167±64)ng/L), 3D-LRFA group ((4.3±3.1) days, (285±102) U/L, (139±43) ng/L) had shorter post-operative stay(t=-2.527, P=0.016), less post-operation ALT changes (t=-2.038, P=0.048) and post-operative TNF-α changes(t=-2.233, P=0.027). Disease-free survival between two groups was significantly different (χ(2)=4.049, P=0.046). Disease-free survival of 12 months survival rates were 77.6% and 65.7% in 3D-LRFA group and LRFA group, respectively.The median disease-free survival was 16.0 months in LRFA group and over 24.0 months in 3D-LRFA group. Three-dimensional model of liver reconstruction based on image information is a powerful tool in liver surgery planning.It helps to simulate tumor location and vital tubular structure, make plan for interventional treatment, and therefore mean puncture time and operation time is shortened, influence on liver function is reduced, hospital stay is decreased and DFS is prolonged.

  7. Perioperative outcomes and complications of open vs laparoscopic extraperitoneal inguinal hernia repair in a mature surgical practice.

    PubMed

    Winslow, E R; Quasebarth, M; Brunt, L M

    2004-02-01

    Although the laparoscopic totally extraperitoneal (TEP) approach to hernia repair has been associated with less pain and a faster postoperative recovery than traditional open repair, many practicing surgeons have been reluctant to adopt this technique because of the lengthy operative times and the learning curve for this procedure. Data from all patients undergoing TEP repair since 1997 and open mesh repair (OPEN) since 1999 were collected prospectively. Selection of surgical approach was based on local hernia factors, anesthetic risk, previous abdominal surgery, and patient preference. Statistical analyses were performed using unpaired t-tests and chi-squared tests. Data are mean +/- SD. TEP repairs were performed in 147 patients and open repairs in 198 patients. Patients in the OPEN group were significantly older (59 +/- 19 years OPEN vs 51 +/- 13 years TEP) and had a higher ASA (1.9 +/- 0.7 OPEN vs 1.5 +/- 0.6 TEP; p < 0.01). TEP repairs were more likely to be carried out for bilateral (33% TEP, 5% OPEN) or recurrent hernias (31% TEP, 11% OPEN) than were open repairs ( p < 0.01). Concurrent procedures accompanied 31% of TEP and 12% of OPEN repairs ( p < 0.01). Operative times (min) were significantly shorter in the TEP group for both unilateral (63 +/- 22 TEP, 70 +/- 20 OPEN; p = 0.02) and bilateral (78 +/- 27 TEP, 102 +/- 27 OPEN; p = 0.01) repairs. Mean operative times decreased over time in the TEP group for both unilateral and bilateral repairs ( p < 0.01). Patients undergoing TEP were more likely ( p < 0.01) to develop urinary retention (7.9% TEP, 1.1% OPEN), but were less likely ( p < 0.01) to have skin numbness (2.8% TEP, 35.8% OPEN) or prolonged groin discomfort (1.4% TEP, 5.3% OPEN). Despite a higher proportion of patients undergoing bilateral repairs, recurrent hernia repair, and concurrent procedures, operative times are shorter for laparoscopic TEP repair than for open mesh repair. TEP repairs can be performed efficiently and without major complications, even when the learning curve is included.

  8. Predictive factors for postoperative visual function of primary chronic rhegmatogenous retinal detachment after scleral buckling.

    PubMed

    Fang, Wei; Li, Jiu-Ke; Jin, Xiao-Hong; Dai, Yuan-Min; Li, Yu-Min

    2016-01-01

    To evaluate predictive factors for postoperative visual function of primary chronic rhegmatgenous retinal detachment (RRD) after sclera buckling (SB). Totally 48 patients (51 eyes) with primary chronic RRD were included in this prospective interventional clinical cases study, which underwent SB alone from June 2008 to December 2014. Age, sex, symptoms duration, detached extension, retinal hole position, size, type, fovea on/off, proliferative vitreoretinopathy (PVR), posterior vitreous detachment (PVD), baseline best corrected visual acuity (BCVA), operative duration, follow up duration, final BCVA were measured. Pearson correlation analysis, Spearman correlation analysis and multivariate linear stepwise regression were used to confirm predictive factors for better final visual acuity. Student's t-test, Wilcoxon two-sample test, Chi-square test and logistic stepwise regression were used to confirm predictive factors for better vision improvement. Baseline BCVA was 0.8313±0.6911 logMAR and final BCVA was 0.4761±0.4956 logMAR. Primary surgical success rate was 92.16% (47/51). Correlation analyses revealed shorter symptoms duration (r=0.3850, P=0.0053), less detached area (r=0.5489, P<0.0001), fovea (r=0.4605, P=0.0007), no PVR (r=0.3138, P=0.0250), better baseline BCVA (r=0.7291, P<0.0001), shorter operative duration (r=0.3233, P=0.0207) and longer follow up (r=-0.3358, P=0.0160) were related with better final BCVA, while independent predictive factors were better baseline BCVA [partial R-square (PR(2))=0.5316, P<0.0001], shorter symptoms duration (PR(2)=0.0609, P=0.0101), longer follow up duration (PR(2)=0.0278, P=0.0477) and shorter operative duration (PR(2)=0.0338, P=0.0350). Patients with vision improvement took up 49.02% (25/51). Univariate and multivariate analyses both revealed predictive factors for better vision improvement were better baseline vision [odds ratio (OR) =50.369, P=0.0041] and longer follow up duration (OR=1.144, P=0.0067). Independent predictive factors for better visual outcome of primary chronic RRD after SB are better baseline BCVA, shorter symptoms duration, shorter operative duration and longer follow up duration, while independent predictive factors for better vision improvement after operation are better baseline vision and longer follow up duration.

  9. Retrograde light-guided laryngoscopy for tracheal intubation: clinical practice and comparison with conventional direct laryngoscopy.

    PubMed

    Yang, Tao; Hou, Jiong; Li, Jinbao; Zhang, Xu; Zhu, Xiaoyan; Ni, Wen; Mao, Yanfei; Deng, Xiaoming

    2013-05-01

    Tracheal intubation with conventional laryngoscopy requires many trials until beginners are sufficiently skilled in intubating patients safely. To facilitate intubation, the authors used retrograde light-guided laryngoscopy (RLGL) and compared its feasibility with conventional direct laryngoscopy (DL). Twenty operators participated in a prospective, randomized, open-label, parallel-arm study. These operators intubated 205 patients randomly according to a computer-generated procedure by using either DL or RLGL (five intubations with each technique). The primary outcome was the success rate of tracheal intubation. The authors evaluated the success rate of tracheal intubation, the time to glottic exposure and tracheal intubation, and the Cormack and Lehane grades. Compared with DL, the success rate was greater in the RLGL group for all five intubations (72% vs. 47%; rate difference, 25%; 95% CI [11.84-38.16%], P < 0.001). This was associated with a shorter time to glottic exposure (median [25th and 75th percentile]; 27 [15; 42] vs. 45 [30; 73] s, P < 0.001), shorter intubation time (66 [44; 120] vs. 120 [69; 120] s, P < 0.001), and decreased throat soreness (mean ± SD; visual analog scale, 2.1 ± 0.9 vs. 3.7 ± 1.0 cm, P = 0.001) in the RLGL group compared to the DL group. RLGL is an alternative intubation technique. In our study, it enables beginners to intubate patients more successfully and quickly than conventional DL.

  10. A comparative study of female sterilization via modified Uchida and silver clip techniques in rural China.

    PubMed

    Qiu, Hongyan; Li, Li; Wu, Shangchun; Liang, Hong; Yuan, Wei; He, Yingqin

    2011-03-01

    To compare the specific effects of 2 female sterilization methods: the modified Uchida technique and the application of silver clips. A total of 2198 women living in rural areas who were still of reproductive age but opting for sterilization were enrolled. The participants were randomly divided into 2 groups, and underwent sterilization by either modified Uchida technique or silver clips. Information on acceptability, operation conditions, effectiveness, adverse effects, and complaints was collected 3, 6, and 12 months after the procedure. No significant difference in effectiveness, adverse effects or chief complaints between the 2 procedures was found. Differences in operative outcome, bleeding volume during the procedure, and operation time were found. A shorter operation time and less bleeding for the silver clip method indicated that female sterilization by this technique was as safe as that by modified Uchida technique. Copyright © 2010 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Examination of Daily Weather in the NCAR CCM

    NASA Astrophysics Data System (ADS)

    Cocke, S. D.

    2006-05-01

    The NCAR CCM is one of the most extensively studied climate models in the scientific community. However, most studies focus primarily on the long term mean behavior, typically monthly or longer time scales. In this study we examine the daily weather in the GCM by performing a series of daily or weekly 10 day forecasts for one year at moderate (T63) and high (T126) resolution. The model is initialized with operational "AVN" and ECMWF analyses, and model performance is compared to that of major operational centers, using conventional skill scores used by the major centers. Such a detailed look at the CCM at shorter time scales may lead to improvements in physical parameterizations, which may in turn lead to improved climate simulations. One finding from this study is that the CCM has a significant drying tendency in the lower troposphere compared to the operational analyses. Another is that the large scale predictability of the GCM is competitive with most of the operational models, particularly in the southern hemisphere.

  12. Effect of preoperative suggestion on postoperative gastrointestinal motility.

    PubMed Central

    Disbrow, E A; Bennett, H L; Owings, J T

    1993-01-01

    Autonomic behavior is subject to direct suggestion. We found that patients undergoing major operations benefit more from instruction than from information and reassurance. We compared the return of intestinal function after intra-abdominal operations in 2 groups of patients: the suggestion group received specific instructions for the early return of gastrointestinal motility, and the control group received an equal-length interview offering reassurance and nonspecific instructions. The suggestion group had a significantly shorter average time to the return of intestinal motility, 2.6 versus 4.1 days. Time to discharge was 6.5 versus 8.1 days. Covariates including duration of operation, amount of intraoperative bowel manipulation, and amount of postoperative narcotics were also examined using the statistical model analysis of covariance. An average savings of $1,200 per patient resulted from this simple 5-minute intervention. In summary, the use of specific physiologically active suggestions given preoperatively in a beleivable manner can reduce the morbidity associated with an intra-abdominal operation by reducing the duration of ileus. PMID:8342264

  13. Omental patch repair effectively treats perforated marginal ulcer following Roux-en-Y gastric bypass.

    PubMed

    Wendling, Mark R; Linn, John G; Keplinger, Kara M; Mikami, Dean J; Perry, Kyle A; Melvin, W Scott; Needleman, Bradley J

    2013-02-01

    Marginal ulcer formation remains a significant complication of Roux-en-Y gastric bypass (RYGB). Up to 1 % of all RYGB patients will develop free perforation of a marginal ulcer. Classically, this complication has required anastomotic revision; however, this approach is associated with significant morbidity. Several small series have suggested that omental patch repair may be effective. The aim of this study was to examine the management of perforated marginal ulcers following RYGB. All patients who underwent operative intervention for perforated ulcers between 2003 and 2011 were reviewed. Those with a history of RYGB with perforation of a marginal ulcer were included in the analysis. Data collected included operative approach, operative time, blood loss, length of hospital stay, complications, smoking history, and steroid or NSAID use. From January 2003 to December 2011, a total of 1,760 patients underwent RYGB at our institution. Eighteen (0.85 %) developed perforation of a marginal ulcer. Three patients' original procedure was performed at another institution. Eight patients (44 %) had at least one risk factor for ulcer formation. Treatment included omental patch repair (laparoscopic, n = 7; open, n = 9) or anastomotic revision (n = 2). Compared to anastomotic revision, omental patch repair had shorter OR time (101 ± 57 vs. 138 ± 2 min), decreased estimated blood loss (70 ± 72 vs. 250 ± 71 mL), and shorter total length of stay (5.6 ± 1.4 vs. 11.0 ± 5.7 days). Perforated marginal ulcer represents a significant complication of RYGB. Patients should be educated to reduce risk factors for perforation, as prolonged proton pump inhibitor therapy may not prevent this complication in a patient with even just one risk factor. In our sample population we found laparoscopic or open omental patch repair to be a safe and effective treatment for this condition and it was associated with decreased operative time, blood loss, and length of stay.

  14. Evaporative Heat Transfer Mechanisms within a Heat Melt Compactor

    NASA Technical Reports Server (NTRS)

    Golliher, Eric L.; Gotti, Daniel J.; Rymut, Joseph Edward; Nguyen, Brian K; Owens, Jay C.; Pace, Gregory S.; Fisher, John W.; Hong, Andrew E.

    2013-01-01

    This paper will discuss the status of microgravity analysis and testing for the development of a Heat Melt Compactor (HMC). Since fluids behave completely differently in microgravity, the evaporation process for the HMC is expected to be different than in 1-g. A thermal model is developed to support the design and operation of the HMC. Also, low-gravity aircraft flight data is described to assess the point at which water may be squeezed out of the HMC during microgravity operation. For optimum heat transfer operation of the HMC, the compaction process should stop prior to any water exiting the HMC, but nevertheless seek to compact as much as possible to cause high heat transfer and therefore shorter evaporation times.

  15. SNR-based queue observations at CFHT

    NASA Astrophysics Data System (ADS)

    Devost, Daniel; Moutou, Claire; Manset, Nadine; Mahoney, Billy; Burdullis, Todd; Cuillandre, Jean-Charles; Racine, René

    2016-07-01

    In an effort to optimize the night time utilizing the exquisite weather on Maunakea, CFHT has equipped its dome with vents and is now moving its Queued Scheduled Observing (QSO)1 based operations toward Signal to Noise Ratio (SNR) observing. In this new mode, individual exposure times for a science program are estimated using a model that uses measurements of the weather conditions as input and the science program is considered completed when the depth required by the scientific requirements are reached. These changes allow CFHT to make better use of the excellent seeing conditions provided by Maunakea, allowing us to complete programs in a shorter time than allocated to the science programs.

  16. Onboard Run-Time Goal Selection for Autonomous Operations

    NASA Technical Reports Server (NTRS)

    Rabideau, Gregg; Chien, Steve; McLaren, David

    2010-01-01

    We describe an efficient, online goal selection algorithm for use onboard spacecraft and its use for selecting goals at runtime. Our focus is on the re-planning that must be performed in a timely manner on the embedded system where computational resources are limited. In particular, our algorithm generates near optimal solutions to problems with fully specified goal requests that oversubscribe available resources but have no temporal flexibility. By using a fast, incremental algorithm, goal selection can be postponed in a "just-in-time" fashion allowing requests to be changed or added at the last minute. This enables shorter response cycles and greater autonomy for the system under control.

  17. 7 CFR 400.202 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... during the normal operation cycle of the business or within one year if the operation cycle is shorter...), International Business Systems (IBM)-defined, byte controlled communications protocol, using control characters...

  18. A comparison of the costs of laparoscopic myomectomy and open myomectomy at a teaching hospital in southern Taiwan.

    PubMed

    Chang, Chi-Chang

    2013-06-01

    To compare the costs of traditional open myomectomy (OM) with laparoscopic myomectomy (LM). A retrospective review was conducted of the medical records of 155 women who underwent traditional open myomectomy (OM) or laparoscopic myomectomy (LM) in a teaching hospital in Taiwan. The total medical service expense and the patient out-of-pocket expense were significantly higher for women who received LM than for women who received OM. However, the operative time and blood loss during surgery were significantly less in women who received LM than in women who received OM. The overall expense is higher for LM than for OM; however, the laparoscopic approach has numerous advantages for patients, including shorter operative time, less blood loss, and a more rapid recovery time. No difference existed in the rate of complications or in the recurrence of disease for the two procedures. Copyright © 2013. Published by Elsevier B.V.

  19. Evidence based medicine and surgical approaches for colon cancer: evidences, benefits and limitations of the laparoscopic vs open resection.

    PubMed

    Lorenzon, Laura; La Torre, Marco; Ziparo, Vincenzo; Montebelli, Francesco; Mercantini, Paolo; Balducci, Genoveffa; Ferri, Mario

    2014-04-07

    To report a meta-analysis of the studies that compared the laparoscopic with the open approach for colon cancer resection. Forty-seven manuscripts were reviewed, 33 of which employed for meta-analysis according to the PRISMA guidelines. The results were differentiated according to the study design (prospective randomized trials vs case-control series) and according to the tumor's location. Outcome measures included: (1) short-term results (operating times, blood losses, bowel function recovery, post-operative pain, return to the oral intake, complications and hospital stay); (2) oncological adequateness (number of nodes harvested in the surgical specimens); and (3) long-term results (including the survivals' rates and incidence of incisional hernias) and (4) costs. Meta-analysis of trials provided evidences in support of the laparoscopic procedures for a several short-term outcomes including: a lower blood loss, an earlier recovery of the bowel function, an earlier return to the oral intake, a shorter hospital stay and a lower morbidity rate. Opposite the operating time has been confirmed shorter in open surgery. The same trend has been reported investigating case-control series and cancer by sites, even though there are some concerns regarding the power of the studies in this latter field due to the small number of trials and the small sample of patients enrolled. The two approaches were comparable regarding the mean number of nodes harvested and long-term results, even though these variables were documented reviewing the literature but were not computable for meta-analysis. The analysis of the costs documented lower costs for the open surgery, however just few studies investigated the incidence of post-operative hernias. Laparoscopy is superior for the majority of short-term results. Future studies should better differentiate these approaches on the basis of tumors' location and the post-operative hernias.

  20. Does Wait-List Size at Registration Influence Time to Surgery? Analysis of a Population-Based Cardiac Surgery Registry

    PubMed Central

    Sobolev, Boris; Levy, Adrian; Hayden, Robert; Kuramoto, Lisa

    2006-01-01

    Objective To determine whether the probability of undergoing coronary bypass surgery within a certain time was related to the number of patients on the wait list at registration for the operation in a publicly funded health system. Methods A prospective cohort study comparing waiting times among patients registered on wait lists at the hospitals delivering adult cardiac surgery. For each calendar week, the list size, the number of new registrations, and the number of direct admissions immediately after angiography characterized the demand for surgery. Results The length of delay in undergoing treatment was associated with list size at registration, with shorter times for shorter lists (log-rank test 1,198.3, p<.0001). When the list size at registration required clearance time over 1 week patients had 42 percent lower odds of undergoing surgery compared with lists with clearance time less than 1 week (odds ratio [OR] 0.58 percent, 95 percent, confidence interval [CI] 0.53–0.63), after adjustment for age, sex, comorbidity, period, and hospital. The weekly number of new registrations exceeding weekly service capacity had an independent effect toward longer service delays when the list size at registration required clearance time less than 1 week (OR 0.56 percent, 95 percent CI 0.45–0.71), but not for longer lists. Every time the operation was performed for a patient requiring surgery without registration on wait lists, the odds of surgery for listed patients were reduced by 6 percent (OR 0.94, CI 0.93–0.95). Conclusion For wait-listed patients, time to surgery depends on the list size at registration, the number of new registrations, as well as on the weekly number of patients who move immediately from angiography to coronary bypass surgery without being registered on a wait list. Hospital managers may use these findings to improve resource planning and to reduce uncertainty when providing advice on expected treatment delays. PMID:16430599

  1. Top-up injection schemes for future circular lepton collider

    NASA Astrophysics Data System (ADS)

    Aiba, M.; Goddard, B.; Oide, K.; Papaphilippou, Y.; Saá Hernández, Á.; Shwartz, D.; White, S.; Zimmermann, F.

    2018-02-01

    Top-up injection is an essential ingredient for the future circular lepton collider (FCC-ee) to maximize the integrated luminosity and it determines the design performance. In ttbar operation mode, with a beam energy of 175 GeV, the design lifetime of ∼1 h is the shortest of the four anticipated operational modes, and the beam lifetime may be even shorter in actual operation. A highly robust top-up injection scheme is consequently imperative. Various top-up methods are investigated and a number of suitable schemes are considered in developing alternative designs for the injection straight section of the collider ring. For the first time, we consider multipole-kicker off-energy injection, for minimizing detector background in top-up operation, and the use of a thin wire septum in a lepton storage ring, for maximizing the luminosity.

  2. Effect of portal access system and surgery type on surgery times during laparoscopic ovariectomy and salpingectomy in captive African lions and cheetahs.

    PubMed

    Hartman, Marthinus Jacobus; Monnet, Eric; Kirberger, Robert Murco; Schoeman, Johan Petrus

    2016-03-02

    A prospective randomized study was used to compare surgery times for laparoscopic ovariectomy and salpingectomy in female African lion (Panthera leo) (n = 14) and cheetah (Acinonyx jubatus) (n = 20) and to compare the use of a multiple portal access system (MPAS) and single portal access system (SPAS) between groups. Two different portal techniques were used, namely MPAS (three separate ports) in lions and SPAS (SILS™ port) in cheetahs, using standard straight laparoscopic instruments. Portal access system and first ovary was not randomized. Five different surgery times were compared for the two different procedures as well as evaluating the use and application of MPAS and SPAS. Carbon dioxide volumes for lions were recorded. In adult lionesses operative time (OPT) (P = 0.016) and total surgical time (TST) (P = 0.032) were significantly shorter for salpingectomy compared to ovariectomy. Similarly in cheetahs OPT (P = 0.001) and TST (P = 0.005) were also shorter for salpingectomy compared to ovariectomy. In contrast, in lion cubs no difference was found in surgery times for ovariectomy and salpingectomy. Total unilateral procedure time was shorter than the respective bilateral time for both procedures (P = 0.019 and P = 0.001) respectively and unilateral salpingectomy was also faster than unilateral ovariectomy (P = 0.035) in cheetahs. Port placement time, suturing time and TST were significantly shorter for SPAS compared to MPAS (P = 0.008). There was, however, no difference in OPT between SPAS and MPAS. Instrument cluttering with SPAS was found to be negligible. There was no difference in mean volume CO2 required to complete ovariectomy in lions but the correlation between bodyweight and total volume of CO2 in lions was significant (rs = 0.867; P = 0.002). Laparoscopic salpingectomy was faster than ovariectomy in both adult lions and cheetahs. Using SPAS, both unilateral procedures were faster than bilateral procedures in cheetahs. Placement and suturing of SPAS in cheetahs was easier and faster compared to three separate ports in lions and lion cubs. The use of standard straight instruments during SPAS did not prolong surgery. Surgery was faster in cubs and CO2 required for laparoscopic sterilization in lions could be determined. Predictable surgery times and CO2 volumes will facilitate the accurate planning and execution of surgery in lions and cheetahs.

  3. Post-operative infection and prophylactic antibiotic administration after radical cystectomy with orthotopic neobladder urinary diversion.

    PubMed

    Shigemura, Katsumi; Tanaka, Kazushi; Matsumoto, Minori; Nakano, Yuzo; Shirakawa, Toshiro; Miyata, Masahiro; Yamashita, Masuo; Arakawa, Soichi; Fujisawa, Masato

    2012-08-01

    The purpose of this study was to investigate the association between prophylactic antibiotic administration (PAA) and post-operative infection in radical cystectomy with orthotopic neobladder urinary diversion carried out for patients with bladder cancer. Fifty-seven consecutive cases were analyzed retrospectively. Post-operative infections were categorized as urinary tract, wound, and remote infections. We used the antibiotics tazobactam/piperacillin (TAZ/PIPC), sulbactam/ampicillin (SBT/ABPC), flomoxef (FMOX), cefazolin (CEZ), cefotiam (CTM), and cefmetazole (CMZ). Twenty-five (43.9%) patients had post-operative infections. Five of these (8.77%) patients had wound infections, 22 (38.6%) patients had urinary tract infections, and 2 (3.51%) had remote infections. Our statistical analysis demonstrated that the patients with TAZ/PIPC used for PAA (5/18: 27.8%) had a significantly lower post-operative infection rate than patients with other antibiotics (24/39: 61.5%) (p = 0.0442). In addition, the patients with a shorter-duration PAA (within 72 h after the operation (48-72 h)) had a significantly lower rate of post-operative infections (12/33: 36.4%) than those with longer-duration PAA (longer than 72-96 h after the operation) (16/24: 66.7%) (p = 0.0239). Taken together, these results suggest that TAZ/PIPC with shorter PAA duration (within 72 h) might lead to a lower rate of post-operative infections. In conclusion, our data showed that PAA with TAZ/PIPC with a shorter duration PAA (within 72 h) might be recommended for radical cystectomy with orthotopic neobladder reconstruction. A prospective study based on our data is desirable to establish or revise guidelines for prophylactic medication for preventing post-operative infection after radical cystectomy with orthotopic neobladder urinary diversion.

  4. Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

    NASA Technical Reports Server (NTRS)

    Huz, Kateryna

    2014-01-01

    RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better detection via good peak separation with a longer run time is a better asset than moderate peak separation with a shorter run time. Even given that RESOLVE is highly interested in water and that mission timeline is of significant importance given the short seven-to-ten-day mission timeline, worse detection with an 8m column may lead to overlooking other substances existing on the moon that could advance planetary science. Thus, I recommend the 20m column. However, if mission timeline and water separation are deemed the highest priority, the 8m column should be selected due to its ability to separate water within a shorter run time than the 20m column.

  5. Peroral Endoscopic Myotomy Versus Heller Myotomy for Achalasia: Pros and Cons.

    PubMed

    Tefas, Cristian; Ababneh, Rami; Tanţău, Marcel

    2018-01-01

    Achalasia is an esophageal motor disorder that has multiple endoscopic and surgical methods of treatment. However, there is no consensus on optimal therapy in patients suffering from this disorder. This review discusses two therapies with similar but technically different concepts, peroral endoscopic myotomy and Heller surgical myotomy. After a brief introduction to the basic problems of achalasia, technical considerations, intra and postprocedural complications are presented and the advantages and disadvantages of the two procedures are discussed, based on the relevant articles in the literature. Heller surgical myotomy and peroral endoscopic myotomy appear to be similar in performance with similar results in terms of gastroesophageal reflux rates. However, with experience being gained in the field of endoscopic myotomy, this procedure seems more advantageous, with similar success rates to those of the established surgical technique, but offering shorter operating times, shorter hospitalizations and, ultimately, lower costs. Celsius.

  6. A fast microchannel plate-scintillator detector for velocity map imaging and imaging mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winter, B.; King, S. J.; Vallance, C., E-mail: claire.vallance@chem.ox.ac.uk

    2014-02-15

    The time resolution achievable using standard position-sensitive ion detectors, consisting of a chevron pair of microchannel plates coupled to a phosphor screen, is primarily limited by the emission lifetime of the phosphor, around 70 ns for the most commonly used P47 phosphor. We demonstrate that poly-para-phenylene laser dyes may be employed extremely effectively as scintillators, exhibiting higher brightness and much shorter decay lifetimes than P47. We provide an extensive characterisation of the properties of such scintillators, with a particular emphasis on applications in velocity-map imaging and microscope-mode imaging mass spectrometry. The most promising of the new scintillators exhibits an electron-to-photonmore » conversion efficiency double that of P47, with an emission lifetime an order of magnitude shorter. The new scintillator screens are vacuum stable and show no signs of signal degradation even over longer periods of operation.« less

  7. [The Misgav Ladach method for cesarean section].

    PubMed

    Habek, Dubravko; Kulas, Tomislav; Karsa, Matija

    2007-04-01

    The Misgav Ladach method for cesarean section is based on the principles of surgical minimalism. This is based on the Joel Cohen laparotomy, somewhat higher than the Pfannenstiel incision. Subcutaneous tissue is left undisturbed apart from the midline, rectus muscles are separated by pulling. The peritoneum is opened by stretching with index fingers. The hysterotomy is closed with one layer extraendometrial continuous absorbable stitches (Vicryl), and the visceral and parietal peritoneal layers are left open. Fascia is stitched with a continuous synthetic absorbable stitch. The skin is closed with intracutaneous resorptive suture or metallic stapler sutures. The Misgav Ladach method is restrictive in the use of sharp instruments preferring manual manipulation: it gives faster recovery, shorter period to normal bowel function, less peritoneal adhesions and less scarring in the abdominal layers, less use of postoperative antibiotics, analgesics and antipyretics, and a shorter anesthetic and operative time. It is ideal for emergency and planned cesarean section.

  8. [Application of individually designed trans-fissure approach in brain surgery: analysis of 90 cases].

    PubMed

    Zhao, Ji-Zong; Wang, Shuo; Zhang, Mao-Zhi; Wang, Lei; Wang, Rong; Tang, Ya-Juan

    2009-01-06

    To explore the feasibility and value of trans-fissure approaches in brain surgery through individually designed craniotomy. Ninety patients with intracranial space-occupying lesions, 47 males and 58 females, aged (43 +/- 14) (1 - 68), were treated by individualized trans-fissure approach surgeries. Linear scalp incision or "horseshoe shape" scalp incision were designed to perform the operation, with a bone flap 3 - 4 cm in diameter. The shortest approach to reach the lesion was decided under the guidance of neuro-navigation and real-time B-mode ultrasonography. Then the lesions were removed through natural cortical fissures. Another 79 patients with intracranial space-occupying lesions, 53 males and 51 females, aged (42 +/- 11) (15 -73), undergoing classical surgeries in the same period were used as control group. The average operation time, size of bone flap, amount of blood loss, hospitalization time, and hospitalization cost were compared between these 2 groups. The operation time of the individually designed trans-fissure approach group was (3.1 +/- 1.6) hours (1.33 - 10.83 hours), significantly shorter than that of the control group [(4.8 +/- 1.9) hrs, P < 0.05]. The amount of blood loss of the individually designed trans-fissure approach group was (173 +/- 168) ml (20 m - 500 ml), significantly less than that of the control group [(410 +/- 61) ml, P < 0.01]. The size of bone flap of the individually designed trans-fissure approach group was (12 +/- 5) cm2 [(1 - 25) cm2], significantly smaller than that of the control group [(20. +/- 9) cm2, P < 0.01]. Four of the 90 patients of the individually designed trans-fissure approach group received retransfusion, compared to 15 in the control group, during operation. No infection or other significant complications occurred after operation in the individually designed trans-fissure approach group. The hospitalization time of the individually designed trans-fissure approach group was (20 +/- 6) days (9 - 39 days), significantly shorter than that of the control group [(24 +/- 7) days, P < 0.01]. The average hospitalization cost of the individually designed trans-fissure approach group was (23171 +/- 7280) yuan RMB; significantly lower than that of the control group [(28096 +/- 10822) yuan, P < 0.01]. One of the land markers of minimally invasive neurosurgery, individualized trans-fissure approach has been proved to be an effective minimally invasive approach that leads to better outcome and fewer complications after operation.

  9. What factors influence cataract waiting list time?

    PubMed Central

    Churchill, A.; Vize, C.; Stewart, O.; Backhouse, O.

    2000-01-01

    AIMS—To determine whether there were any specific factors that influenced waiting list time (WLT) for patients undergoing cataract surgery.
METHODS—70 preoperative cataract patients were interviewed by one of the authors using a questionnaire to score visual acuity, coexisting ocular pathology and disabilities, threat to independent living/employment, and perceived visual handicap for detailed, gross, and driving vision. Individuals were analysed separately according to whether it was their first or second cataract operation.
RESULTS—The median WLT for first eye surgery was 9 months (n = 31) and 13 months for second eye surgery (n = 36). The WLT ranged from 2 to 25 months for first eyes and 0.25-18 months for second eyes. Where there was a perceived threat to independent living or employment the WLT was found to be significantly shorter than the median. A high overall score correlated with a shorter WLT. Surgical priority was also given to individuals with anisometropia >3 dioptres.
CONCLUSION—This study has demonstrated that there are specific factors that influence clinicians when prioritising patients for cataract surgery.

 PMID:10729304

  10. Arthroscopic ankle arthrodesis with intra-articular distraction.

    PubMed

    Kim, Hyong Nyun; Jeon, June Young; Noh, Kyu Cheol; Kim, Hong Kyun; Dong, Quanyu; Park, Yong Wook

    2014-01-01

    Arthroscopic ankle arthrodesis has shown high rates of union comparable to those with open arthrodesis but with substantially less postoperative morbidity, shorter operative times, less blood loss, and shorter hospital stays. To easily perform arthroscopic resection of the articular cartilage, sufficient distraction of the joint is necessary to insert the arthroscope and instruments. However, sometimes, standard noninvasive ankle distraction will not be sufficient in post-traumatic ankle arthritis, with the development of arthrofibrosis and joint contracture after severe ankle trauma. In the present report, we describe a technique to distract the ankle joint by inserting a 4.6-mm stainless steel cannula with a blunt trocar inside the joint. The cannula allowed sufficient intra-articular distraction, and, at the same time, a 4.0-mm arthroscope can be inserted through the cannula to view the joint. Screws can be inserted to fix the joint under fluoroscopic guidance without changing the patient's position or removing the noninvasive distraction device and leg holder, which are often necessary during standard arthroscopic arthrodesis with noninvasive distraction. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Electromagnetic Real Time Navigation in the Region of the Posterior Pelvic Ring: An Experimental In-Vitro Feasibility Study and Comparison of Image Guided Techniques.

    PubMed

    Pishnamaz, Miguel; Wilkmann, Christoph; Na, Hong-Sik; Pfeffer, Jochen; Hänisch, Christoph; Janssen, Max; Bruners, Philipp; Kobbe, Philipp; Hildebrand, Frank; Schmitz-Rode, Thomas; Pape, Hans-Christoph

    2016-01-01

    Electromagnetic tracking is a relatively new technique that allows real time navigation in the absence of radiation. The aim of this study was to prove the feasibility of this technique for the treatment of posterior pelvic ring fractures and to compare the results with established image guided procedures. Tests were performed in pelvic specimens (Sawbones®) with standardized sacral fractures (Type Denis I or II). A gel matrix simulated the operative approach and a cover was used to disable visual control. The electromagnetic setup was performed by using a custom made carbon reference plate and a prototype stainless steel K-wire with an integrated sensor coil. Four different test series were performed: Group OCT: Optical navigation using preoperative CT-scans; group O3D: Optical navigation using intraoperative 3-D-fluoroscopy; group Fluoro: Conventional 2-D-fluoroscopy; group EMT: Electromagnetic navigation combined with a preoperative Dyna-CT. Accuracy of screw placement was analyzed by standardized postoperative CT-scan for each specimen. Operation time and intraoperative radiation exposure for the surgeon was documented. All data was analyzed using SPSS (Version 20, 76 Chicago, IL, USA). Statistical significance was defined as p< 0.05. 160 iliosacral screws were placed (40 per group). EMT resulted in a significantly higher incidence of optimal screw placement (EMT: 36/40) compared to the groups Fluoro (30/40; p< 0.05) and OCT (31/40; p< 0.05). Results between EMT and O3D were comparable (O3D: 37/40; n.s.). Also, the operation time was comparable between groups EMT and O3D (EMT 7.62 min vs. O3D 7.98 min; n.s.), while the surgical time was significantly shorter compared to the Fluoro group (10.69 min; p< 0.001) and the OCT group (13.3 min; p< 0.001). Electromagnetic guided iliosacral screw placement is a feasible procedure. In our experimental setup, this method was associated with improved accuracy of screw placement and shorter operation time when compared with the conventional fluoroscopy guided technique and compared to the optical navigation using preoperative CT-scans. Further studies are necessary to rule out drawbacks of this technique regarding ferromagnetic objects.

  12. Facial Nerve Repair: Fibrin Adhesive Coaptation versus Epineurial Suture Repair in a Rodent Model

    PubMed Central

    Knox, Christopher J.; Hohman, Marc H.; Kleiss, Ingrid J.; Weinberg, Julie S.; Heaton, James T.; Hadlock, Tessa A.

    2013-01-01

    Objectives/Hypothesis Repair of the transected facial nerve has traditionally been accomplished with microsurgical neurorrhaphy; however, fibrin adhesive coaptation (FAC) of peripheral nerves has become increasingly popular over the past decade. We compared functional recovery following suture neurorrhaphy to FAC in a rodent facial nerve model. Study Design Prospective, randomized animal study. Methods Sixteen rats underwent transection and repair of the facial nerve proximal to the pes anserinus. Eight animals underwent epineurial suture (ES) neurorrhaphy, and eight underwent repair with fibrin adhesive (FA). Surgical times were documented for all procedures. Whisking function was analyzed on a weekly basis for both groups across 15 weeks of recovery. Results Rats experienced whisking recovery consistent in time course and degree with prior studies of rodent facial nerve transection and repair. There were no significant differences in whisking amplitude, velocity, or acceleration between suture and FA groups. However, the neurorrhaphy time with FA was 70% shorter than for ES (P < 0.05). Conclusion Although we found no difference in whisking recovery between suture and FA repair of the main trunk of the rat facial nerve, the significantly shorter operative time for FA repair makes this technique an attractive option. The relative advantages of both techniques are discussed. PMID:23188676

  13. Facial nerve repair: fibrin adhesive coaptation versus epineurial suture repair in a rodent model.

    PubMed

    Knox, Christopher J; Hohman, Marc H; Kleiss, Ingrid J; Weinberg, Julie S; Heaton, James T; Hadlock, Tessa A

    2013-07-01

    Repair of the transected facial nerve has traditionally been accomplished with microsurgical neurorrhaphy; however, fibrin adhesive coaptation (FAC) of peripheral nerves has become increasingly popular over the past decade. We compared functional recovery following suture neurorrhaphy to FAC in a rodent facial nerve model. Prospective, randomized animal study. Sixteen rats underwent transection and repair of the facial nerve proximal to the pes anserinus. Eight animals underwent epineurial suture (ES) neurorrhaphy, and eight underwent repair with fibrin adhesive (FA). Surgical times were documented for all procedures. Whisking function was analyzed on a weekly basis for both groups across 15 weeks of recovery. Rats experienced whisking recovery consistent in time course and degree with prior studies of rodent facial nerve transection and repair. There were no significant differences in whisking amplitude, velocity, or acceleration between suture and FA groups. However, the neurorrhaphy time with FA was 70% shorter than for ES (P < 0.05). Although we found no difference in whisking recovery between suture and FA repair of the main trunk of the rat facial nerve, the significantly shorter operative time for FA repair makes this technique an attractive option. The relative advantages of both techniques are discussed. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  14. Trainees do not negatively impact the institutional learning curve for robotic prostatectomy as characterized by operative time, estimated blood loss, and positive surgical margin rate.

    PubMed

    Schroeck, Florian R; de Sousa, Chiquita A Palha; Kalman, Ross A; Kalia, Maitri S; Pierre, Sean A; Haleblian, George E; Sun, Leon; Moul, Judd W; Albala, David M

    2008-04-01

    We evaluated the learning curves and perioperative outcomes of an experienced laparoscopic surgeon and his trainees to assess our structured teaching program. We retrieved 383 patients undergoing robot-assisted laparoscopic prostatectomy (RALP) from our database. Trainees completed a structured teaching program and were categorized as early (days 0 to 232), mid (days 566 to 797), and late (days 825 to 1218) according to the time period in which they were working with the mentor. We compared operative times, estimated blood loss (EBL), and positive surgical margin (PSM) rates between the trainees and the mentor (Mann-Whitney and Chi-square test). Association of EBL, body mass index (BMI), and prostate weight with operative time was evaluated in multivariate linear regression analysis. Median operative times of the early, mid, and late trainees (258, 220, and 200 minutes) significantly decreased and were similar to the corresponding senior surgeon's (254, 242, and 180 minutes). Operative times decreased with lower BMI, EBL, and prostate weight (P = 0.006, P <0.001, and P <0.001, respectively). Overall, EBL (150 mL vs. 150 mL, P = 0.215) and PSM rates (20% vs. 18.6%, P = 0.741) did not differ between the mentor and the trainees. A structured teaching program for RALP is effective and trainees are able to adopt the increased efficiency and skills of their mentor. Lower BMI, EBL, and prostate weight were associated with shorter operative times. Trainees performing the procedure did not negatively affect EBL and positive surgical margin rate.

  15. The Misgav Ladach method for cesarean section: method description.

    PubMed

    Holmgren, G; Sjöholm, L; Stark, M

    1999-08-01

    A method description is given for the Misgav Ladach method for cesarean section. This is based on the Joel-Cohen incision originally introduced for hysterectomy. The incision is a straight transverse incision somewhat higher than the Pfannenstiel incision. The subcutaneous tissue is left undisturbed apart from the midline. The rectus sheath is separated along its fibres. The rectus muscles are separated by pulling. The peritoneum is opened by stretching with index fingers. The uterus is opened with an index finger and the hole enlarged between the index finger of one hand and the thumb on the other. The uterus is closed with a one-layer continuous locking stitch. The visceral and parietal peritoneal layers are left open. The rectus muscle is not stitched. The rectus sheath is stitched with a continuous non-locking stitch. The skin is closed with two or three mattress sutures. The space in between is apposed with non-traumatic forceps for 5 minutes. The basic philosophy is to work in harmony with the body's anatomy and physiology and not against them. The method is restrictive in the use of sharp instruments, preferring manual manipulation. The method gives quicker recovery, less use of post-operative antibiotics, antifebrile medicines and analgesics. There is a shorter anesthetic and shorter working time for the operative team. It is suitable for both emergency and planned operations.

  16. [Effects of robot-assisted minimally invasive transforaminal lumbar interbody fusion and traditional open surgery in the treatment of lumbar spondylolisthesis].

    PubMed

    Cui, G Y; Tian, W; He, D; Xing, Y G; Liu, B; Yuan, Q; Wang, Y Q; Sun, Y Q

    2017-07-01

    Objective: To compare the clinical effects of robot-assisted minimally invasive transforaminal lumbar interbody fusion (TLIF) and traditional open TLIF in the treatment of lumbar spondylolisthesis. Methods: A total of 41 patients with lumbar spondylolisthesis accepted surgical treatment in Department of Spinal Surgery of Beijing Jishuitan Hospital From July 2015 to April 2016 were retrospectively analyzed. There were 16 cases accepted robot-assisted minimally invasive TLIF and 25 accepted traditional open TLIF. The operation time, X-ray radiation exposure time, perioperative bleeding, drainage volume, time of hospitalization, time for pain relief, time for ambulatory recovery, visual analogue scale (VAS), Oswestry disability index (ODI) and complications were compared. T test and χ(2) were used to analyze data. Results: There were no significant difference in gender, age, numbers, degrees, pre-operative VAS and ODI in spondylolisthesis (all P >0.05). Compared with traditional open TLIF group, the robot-assisted minimally invasive TLIF group had less perioperative bleeding ((187.5±18.4) ml vs . (332.1±23.5) ml), less drainage volume ((103.1±15.6) ml vs . (261.3±19.8) ml), shorter hospitalization ((7.8±1.9) days vs . (10.0±1.6) days), shorter time for pain relief ((2.8±1.0) days vs . (5.2±1.1) days), shorter time for ambulatory recovery ((1.7±0.9) days vs . (2.9±1.3) days) and less VAS of the third day postoperatively (2.2±0.9 vs . 4.2±2.4) ( t =2.762-16.738, all P <0.05), but need more operation time ((151.3±12.3) minutes vs . (102.2±7.1) minutes) and more X-ray radiation exposure ((26.1±3.3) seconds vs . (5.5±2.1) seconds) ( t =6.125, 15.168, both P <0.01). In both groups ODI was significantly lower in final follow-up than that of the pre-operation ( t =12.215, 14.036, P <0.01). Intervertebral disc height of the final follow-up in both groups were significantly larger than that of the preoperation (robot-assisted minimally invasive TLIF group: (11.8 ± 2.8) mm vs . (7.5 ± 1.9) mm, traditional open TLIF group: (12.7 ± 2.5) mm vs . (7.9±2.0) mm), and so was the lumbar lordosis angle (robot-assisted minimally invasive TLIF group: (48.7±9.2)° vs . (39.6±7.9)°, traditional open TLIF group: (50.1±10.8)° vs . (41.4±8.8)°), the lordosis angle of the slippage segment (robot-assisted minimally invasive TLIF group: (18.7±5.6)° vs . (10.9±3.8)°, traditional open TLIF group: (17.6±6.1)° vs .(8.7±3.2)°) ( t =4.128-16.738, all P <0.01). Slippage rate of the final follow-up in both groups were significantly smaller than those of the pre-operation (robot-assisted minimally invasive TLIF group: (5.3±2.3) % vs . (27.8±7.2) %, traditional open TLIF group: (6.6±2.8) % vs . (29.1±9.5) %) ( t =11.410, 18.504, both P <0.01). There was no difference of the upper data between two groups ( t =0.106-1.227, P >0.05). The results of the post-operative CT showed that the pedicle screws in the robot-assisted minimally invasive TLIF group were more precisely placed than traditional open TLIF group (χ(2)=4.247, P =0.039). The mean follow-up time was 8 months (ranging from 3 to 12 months). There were no significant difference in outcomes between the two groups (χ(2)=0.366, P =0.545). Conclusions: In the treatment of lumbar spondylolisthesis, Robot-assisted minimally invasive TLIF can lead to less perioperative bleeding, less post-operative pain, and quicker recovery than traditional open TLIF surgery, but it needs more operation time and radiation exposure.

  17. Bipolar plasma vaporization using plasma-cutting and plasma-loop electrodes versus cold-knife transurethral incision for the treatment of posterior urethral stricture: a prospective, randomized study.

    PubMed

    Cai, Wansong; Chen, Zhiyuan; Wen, Liping; Jiang, Xiangxin; Liu, Xiuheng

    2016-01-01

    Evaluate the efficiency and safety of bipolar plasma vaporization using plasma-cutting and plasma-loop electrodes for the treatment of posterior urethral stricture. Compare the outcomes following bipolar plasma vaporization with conventional cold-knife urethrotomy. A randomized trial was performed to compare patient outcomes from the bipolar and cold-knife groups. All patients were assessed at 6 and 12 months postoperatively via urethrography and uroflowmetry. At the end of the first postoperative year, ureteroscopy was performed to evaluate the efficacy of the procedure. The mean follow-up time was 13.9 months (range: 12 to 21 months). If re-stenosis was not identified by both urethrography and ureteroscopy, the procedure was considered "successful". Fifty-three male patients with posterior urethral strictures were selected and randomly divided into two groups: bipolar group (n=27) or cold-knife group (n=26). Patients in the bipolar group experienced a shorter operative time compared to the cold-knife group (23.45±7.64 hours vs 33.45±5.45 hours, respectively). The 12-month postoperative Qmax was faster in the bipolar group than in the cold-knife group (15.54±2.78 ml/sec vs 18.25±2.12 ml/sec, respectively). In the bipolar group, the recurrence-free rate was 81.5% at a mean follow-up time of 13.9 months. In the cold-knife group, the recurrence-free rate was 53.8%. The application of bipolar plasma-cutting and plasma-loop electrodes for the management of urethral stricture disease is a safe and reliable method that minimizes the morbidity of urethral stricture resection. The advantages include a lower recurrence rate and shorter operative time compared to the cold-knife technique.

  18. [Development and clinical application of a new type of anatomical locking plate for sternoclavicular joint fracture and dislocation].

    PubMed

    Sun, Yuanlin; Yang, Yunkang; Ge, Jianhua; Yang, Kun; Xiang, Feifan; Zhou, Ju; Liang, Jie

    2018-03-01

    To report a new type of anatomical locking plate for sternocalvicular joint, and investigate its effectiveness in treatment of sternoclavicular joint fracture and dislocation. A new type of anatomical locking plate for sternoclavicular joint was developed, which accorded with the anatomical features and biomechanical characteristics of Chinese sternoclavicular joint. By adopting the method of clinical randomized controlled study, 32 patients with the sternoclavicular joint fracture and dislocation who met the selection criteria between June 2008 and May 2015 were randomly divided into groups A and B ( n =16), and the patients were treated with new anatomic locking plate and distal radial T locking plate internal fixation, respectively. There was no significant difference between 2 groups in gender, age, injured side, body mass index, cause of injury, type of injury, the time from injury to operation, and preoperative Rockwood grading score ( P >0.05). The operation time, intraoperative blood loss, incision length, hospitalization time, and postoperative complications in 2 groups were recorded, and the effectiveness was evaluated by Rockwood grading score. The operations of 2 groups completed successfully. The operation time, intraoperative blood loss, and hospitalization time in group A were significantly less than those in group B ( P <0.05), but there was no significant difference in the incision length between 2 groups ( t =0.672, P =0.507). All the patients were followed up 18-30 months (mean, 24 months). In group A, there were 1 case of sternoclavicular joint pain and 2 cases of wound infection; in group B, there were 1 case of sternoclavicular joint pain, 1 case of internal fixation loosening, and 1 case of sternoclavicular joint re-dislocation; there was no significant difference in complication incidence between 2 groups ( P =1.000). The Rockwood grading scores at each time point after operation in 2 groups were significantly higher than those before operation. At 1 month after operation, the Rockwood grading score in group A was significantly higher than that in group B ( t= 2.270, P =0.031); but there was no significant difference in the Rockwood grading scores between the 2 groups at 6 months and at last follow-up ( P >0.05). At last follow-up, according to the Rockwood scoring standard, the results of group A were excellent in 13 cases, good in 2 cases, poor in 1 case, the excellent and good rate was 93.75%; the results of group B were excellent in 11 cases, good in 4 cases, poor in 1 case, and the excellent and good rate was 93.75%; there was no significant difference between 2 groups ( Z =-0.748, P =0.455). The new type of anatomic locking plate accords with the Chinese anatomical characteristics. It has the advantages of easy operative procedure, less surgical trauma, shorter operation time, less intraoperative blood loss, shorter hospitalization time, and it can achieve better results in the treatment of sternoclavicular joint fracture and dislocation.

  19. Ultrasound-assisted oxidative desulfurization of bunker-C oil using tert-butyl hydroperoxide.

    PubMed

    Tang, Qiong; Lin, Song; Cheng, Ying; Liu, Sujun; Xiong, Jun-Ru

    2013-09-01

    This work investigated the ultrasonic assisted oxidative desulfurization of bunker-C oil with TBHP/MoO3 system. The operational parameters for the desulfurization procedure such as ultrasonic irradiation time, ultrasonic wave amplitude, catalyst initial concentration and oxidation agent initial concentration were studied. The experimental results show that the present oxidation system was very efficient for the desulfurization of bunker-C oil and ~35% sulfur was removed which was dependent on operational parameters. The application of ultrasonic irradiation allowed sulfur removal in a shorter time. The stronger the solvent polarity is, the higher the sulfur removal rate, but the recovery rate of oil is lower. The sulfur compounds in bunker-C oil reacted with TBHP to produce corresponding sulfoxide, and further oxidation produced the corresponding sulfone. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Optimizing time management after perforation by colonoscopy results in better outcome for the patients.

    PubMed

    Rumstadt, Bernhard; Schilling, Dieter

    2008-01-01

    Perforation during colonoscopy is a rare but severe complication. The aim of this study was to assess the time management and laparoscopic therapy of this complication and to evaluate patient outcomes. A retrospective analysis was done on 15 patients operated for a perforation from colonoscopy between January 2000 and December 2006. Three perforations occurred during diagnostic and 12 perforations during interventional colonoscopy. Two perforations occurred as transmural thermal injury to the colon wall. Peritonitis was found in 4 cases and significantly correlated with the mean time between perforation and operation. Twelve perforations were oversewn laparoscopically and 3 perforations were oversewn by laparotomy. After laparoscopic treatment, hospital stay was significantly shorter than after laparotomy. One patient had a postoperative wound infection, mortality was 0%. Laparoscopic oversewing is a safe and effective method in the treatment of perforation from colonoscopy. Optimizing the time range between perforation and laparoscopic therapy results in a better outcome for the patients.

  1. Adjustable patella grapple versus cannulated screw and cable technique for treatment of transverse patellar fractures.

    PubMed

    Yan, Ning; Yang, Anli; Liu, Xiaodong; Cai, Feng; Liu, Liang; Chang, Shimin

    2014-03-01

    Although the cannulated screw and cable (CSC) tension band technique is an effective method for fixation of transverse patellar fractures, it has shortcomings, such as extensive soft tissue damage, osseous substance damage, and complex manipulation. We conducted a retrospective comparison of the adjustable patella grapple (APG) technique and the CSC tension band technique. We retrospectively reviewed 78 patients with transverse patellar fractures (45 in the APG group and 33 in the CSC group). Follow-up was 18 months. Comparison criteria were operation time, fracture reduction, fracture healing time, the knee injury and osteoarthritis outcome score for knee function, and complications. The APG group showed shorter operation time and equal fracture reduction, fracture healing time, and knee function compared with the CSC group. Eleven patients in the APG group experienced skin irritation generated by implants. There was no complication in the CSC group. The APG technique should be considered as an alternative method for treatment of transverse patellar fractures.

  2. The Analysis of Electrical Energy Consumption of the Impact Screwdriver During Assembly of Fixed Threaded Joints

    NASA Astrophysics Data System (ADS)

    Grinevich, I.; Nikishin, Vl.; Mozga, N.; Laitans, M.

    2017-06-01

    The paper deals with the possibilities of reducing the consumption of electrical energy of the impact screwdriver during the assembly of fixed threaded joints. The recommendations related to a decrease in electrical energy consumption would allow reducing product costs but so far there have been no such recommendations from the producers of the tool as to the effective operating regimes of the impact screwdrivers in relation to electrical energy consumption and necessary tightening moment of the nut. The aim of the study is to find out the economical operating mode of the electrical impact screwdriver when assembling fixed threaded joints. By varying the set speed of the rotor head and working time of the impact mechanism, there is an opportunity to determine electrical energy consumption of the tool for the given tightening moment. The results of the experiment show that at the same tightening moment obtained the electrical energy consumption of the impact screwdriver is less at a higher starting set speed of the rotor head but shorter operating time of the impact mechanism than at a lower speed of the rotor head and longer operating time of the impact mechanism.

  3. Recent advances in the reconstruction of cranio-maxillofacial defects using computer-aided design/computer-aided manufacturing.

    PubMed

    Oh, Ji-Hyeon

    2018-12-01

    With the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it has been possible to reconstruct the cranio-maxillofacial defect with more accurate preoperative planning, precise patient-specific implants (PSIs), and shorter operation times. The manufacturing processes include subtractive manufacturing and additive manufacturing and should be selected in consideration of the material type, available technology, post-processing, accuracy, lead time, properties, and surface quality. Materials such as titanium, polyethylene, polyetheretherketone (PEEK), hydroxyapatite (HA), poly-DL-lactic acid (PDLLA), polylactide-co-glycolide acid (PLGA), and calcium phosphate are used. Design methods for the reconstruction of cranio-maxillofacial defects include the use of a pre-operative model printed with pre-operative data, printing a cutting guide or template after virtual surgery, a model after virtual surgery printed with reconstructed data using a mirror image, and manufacturing PSIs by directly obtaining PSI data after reconstruction using a mirror image. By selecting the appropriate design method, manufacturing process, and implant material according to the case, it is possible to obtain a more accurate surgical procedure, reduced operation time, the prevention of various complications that can occur using the traditional method, and predictive results compared to the traditional method.

  4. Comparative Study of Hand-Sutured versus Circular Stapled Anastomosis for Gastrojejunostomy in Laparoscopy Assisted Distal Gastrectomy

    PubMed Central

    Seo, Su Hyun; Kim, Min Chan; Choi, Hong Jo; Jung, Ghap Joong

    2012-01-01

    Purpose Mechanical stapler is regarded as a good alternative to the hand sewing technique, when used in gastric reconstruction. The circular stapling method has been widely applied to gastrectomy (open orlaparoscopic), for gastric cancer. We illustrated and compared the hand-sutured method to the circular stapling method, for Billroth-II, in patients who underwent laparoscopy assisted distal gastrectomy for gastric cancer. Materials and Methods Between April 2009 and May 2011, 60 patients who underwent laparoscopy assisted distal gastrectomy, with Billroth-II, were enrolled. Hand-sutured Billroth-II was performed in 40 patients (manual group) and circular stapler Billroth-II was performed in 20 patients (stapler group). Clinicopathological features and post-operative outcomes were evaluated and compared between the two groups. Results Nosignificant differences were observed in clinicopathologic parameters and post-operative outcomes, except in the operation times. Operation times and anastomosis times were significantly shorter in the stapler group (P=0.004 and P<0.001). Conclusions Compared to the hand-sutured method, the circular stapling method can be applied safely and more efficiently, when performing Billroth-II anastomosis, after laparoscopy assisted distal gastrectomy in patients with gastric cancer. PMID:22792525

  5. [MINIMALLY INVASIVE PROCEDURE FOR CORRECTION OF PECTUS CARINATUM].

    PubMed

    Xu, Bing; Liu, Wenying

    2015-04-01

    To explore the method and experience in correction of pectus carinatum with minimally invasive procedure. Between June 2010 and January 2014, 30 patients with pectus carinatum were corrected by minimally invasive procedure. There were 21 boys and 9 girls whose average age was 13 years and 2 months (range, from 8 years and 10 months to 18 years and 9 months), including 24 cases of first operation, 2 recurrence after traditional pectus carinatum correction, and 4 cases secondary to median thoracotomy. Thirty patients had symmetric and asymmetric mild pectus carinatum. The operation was performed successfully in all patients, and no severe complication occurred. The operation time was 42-95 minutes (mean, 70 minutes). The bleeding volume during operation was 4-30 mL (mean, 10 mL). The time from operation to discharge was 6-10 days (mean, 7 days). The average time of follow-up was 25 months (range, 9-54 months). All surgical wound healed primarily with no infection. The X-ray films showed slight pneumothorax in 7 cases, and it was absorbed after 1 month without treatment. Loosening of internal fixation was found in 1 patient because of trauma at 6 months, and operation was performed again. The bar was removed at 2 years in 21 patients. The patients had good thoracic contour and normal activity. Minimally invasive procedure for correction of pectus carinatum is safe and will get satisfactory effect in maintaining thoracic contour. It has also less trauma and shorter operation time.

  6. [Application of hand-use ProTaper instruments in endodontic treatment of molar canals].

    PubMed

    Ma, Sui-qi; Xie, Qian; Zhou, Yin-feng

    2010-07-01

    To evaluate the application of hand-use ProTaper instruments in endodontic treatment of molar canals. A total of 203 permanent molars were randomly divided into the experimental group (99 molars) and control group (104 molars) prepared by hand-use ProTaper instruments and standard stainless steel K-file, respectively. The molars in the two groups were obturated by cold lateral condensation technique. The root canal preparation and obturation were evaluated by radiograph, and the working time of preparation and post-operative emergencies were analyzed. The preparation time in the experimental group was obviously shorter than that in the control group (P<0.01). The rate of satisfactory effect was significantly higher in the experimental group than in the control group (P<0.01), and the rate of post-operative emergencies was significantly lower in the experimental group (P<0.01). The application of hand-use ProTaper instruments may improve the effect of root canal treatment of the molars and shorten the working time and reduce the post-operative emergencies.

  7. [Comparative analysis of mechanical and manual cervical esophagogastric anastomosis following esophagectomy for esophageal cancer].

    PubMed

    Cayi, Ruijun; Li, Mei; Xiong, Gang; Cai, Kaican; Wang, Wujun

    2012-06-01

    To compare the complications associated with mechanical and manual cervical esophagogastric anastomosis following esophagectomy for esophageal cancer. From September, 2004 to June, 2007, 227 patients with middle and upper thoracic esophageal cancer underwent cervical esophagogastric anastomosis after esophagectomy. The patients were randomized into two groups and cervical esophagogastric anastomosis was performed using a stapler (n=102) or manually (n=125). The incidence of postoperative complications and operative time were compared between the two groups. In manual anastomosis group, anastomotic leak and anastomotic stricture occurred in 14.4% (18/125) and 8.8.% (11/125) of the patients, significantly higher than the incidences of 2.9% (3/102) and 3.9% (4/102) in the mechanical anastomosis group (P<0.01). Manual anastomosis required a significantly longer operative time than mechanical anastomosis (52∓12 vs 25∓5 min, P<0.01). The use of circular mechanical stapler in cervical esophagogastric anastomosis is associated with a lower rate of anastomotic leak and a shorter operative time, and is easy to learn and standardize to reduce the complications of the anastomosis.

  8. Comparison of Lichtenstein inguinal hernia repair with the tension-free Desarda technique: a clinical audit and review of the literature.

    PubMed

    Zulu, Halalisani Goodman; Mewa Kinoo, Suman; Singh, Bhugwan

    2016-07-01

    Ours was a retrospective chart review of all elective open inguinal hernia repairs performed in a single unit at King Edward VIII Hospital, South Africa over an 18-month period. Comparison was made regarding duration of operation, length of hospital stay and complications such as pain, haematoma formation and recurrence between the Lichtenstein and Desarda techniques. The latter was noted to have a shorter operative time and avoided cost and possible complications of mesh usage, which are significant in resource-deprived settings. A larger comparative study with longer follow-up is needed to evaluate the wider suitability of the Desarda repair. © The Author(s) 2016.

  9. Flight contaminant trace analyser. Phase 1: Chromatographic input system

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The development of a chromatographic column capable of resolving compounds associated with spacecraft atmospheres is presented. Consideration is given to sampling techniques, column parameters and operation, and column interface with a mass spectrometer. A capillary column coated with a mixture of polyalkylene glycols is found to provide the best selectivity for resolving multicomponent mixtures found in spacecraft atmospheres. Temperature programming and isothermal operation of the column are evaluated and it is found that temperature programming has a shorter analysis time for a given carrier gas flow rate and overall superior resolution. It is observed that hydrogen provides a 15% savings in analysis time over helium. Following the optimization of column operational parameters, a mixed phase Ucon capillary is prepared for evaluation during the column test period in which the test sample is automatically analyzed. Analysis of the multicomponent test mixture is completed within 45 minutes provided temperature programming is used. All but two of the test compounds are well resolved.

  10. Clinical efficacy of low-temperature radiofrequency ablation of pharyngolaryngeal cyst in 84 Chinese infants.

    PubMed

    Wang, Zhinan; Zhang, Yamin; Ye, Yuhua; Yao, Wei; Xu, Zhongqiang; Xia, Zhongfang; Wang, Shufen; Zhou, Chengyong

    2017-11-01

    The aim of the study is to investigate the advantages and disadvantages of low-temperature radiofrequency ablation of pharyngolaryngeal cyst.The study population was composed of 84 children diagnosed with pharyngolaryngeal cyst who underwent surgical treatment at the Department of Otolaryngology, Wuhan Children's Hospital, Wuhan, China, between January 1984 and December 2013. All patients were operated using a self-retaining laryngoscope and were divided into 3 groups: traditional cystectomy group (N = 9), dynamic cutting system group (N = 18), and low-temperature radiofrequency ablation group (N = 57). Clinical outcomes were analyzed to assess the efficacy of low-temperature radiofrequency ablation in treatment of pharyngolaryngeal cyst.Compared with traditional cystectomy group or dynamic cutting system group, operation time was shorter, bleeding was less and one-year recurrence rate was much lower in low-temperature radiofrequency ablation group. However, operation time and bleeding was not statistically different between traditional cystectomy and dynamic cutting system group.Low-temperature radiofrequency ablation may be an effective substitute for treating pharyngolaryngeal cyst.

  11. Experience and learning curve of retroperitoneal laparoscopic ureterolithotomy for upper ureteral calculi.

    PubMed

    Fan, Tianyong; Xian, Peng; Yang, Lu; Liu, Yong; Wei, Qiang; Li, Hong

    2009-11-01

    To summarize our experience and evaluate the learning curve of retroperitoneal laparoscopic ureterolithotomy of the upper ureter. Between May 2004 and May 2007, 40 patients underwent retroperitoneal laparoscopic ureterolithotomy of the upper ureter. We divided the first and last 20 patients into group I and group II. There was no statistical difference in stone size between groups. Operative time and complications were measured as a basis for the assessment of the learning curve. In group I, the complication rate was 15% (3/20), including two patients whose procedure was converted to open surgery because of intraoperative bleeding, and one patient who experienced urine leakage because of a displaced Double-J ureteral stent. In group II, no postoperative complications occurred, while the mean operative time was significantly shorter compared with the earlier operations (65 vs 120 min). Retroperitoneal laparoscopic ureterolithotomy is safe and effective for large or impacted stones of the upper ureter. It is associated with a short learning curve in the setting of an active laparoscopic practice for selected patients.

  12. Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method

    PubMed Central

    Hu, Ying Kai; Xie, Qian Yang; Yang, Chi; Xu, Guang Zhou

    2017-01-01

    Abstract The aim of this study was to introduce a novel method of mesiodens extraction using a vascularized pedicled bone flap by piezosurgery and to compare the differences between a computer-aided design surgical guide template and free-hand operation. A total of 8 patients with mesiodens, 4 with a surgical guide (group I), and 4 without it (group II) were included in the study. The surgical design was to construct a trapdoor pedicle on the superior mucoperiosteal attachment with application of piezosurgery. The bone lid was repositioned after mesiodens extraction. Group I patients underwent surgeries based on the preoperative planning with surgical guide templates, while group II patients underwent free-hand operation. The outcome variables were success rate, intraoperative time, anterior nasal spine (ANS) position, changes of nasolabial angle (NLA), and major complications. Data from the 2 groups were compared by SPSS 17.0, using Wilcoxon test. The operative time was significantly shorter in group I patients. All the mesiodentes were extracted successfully and no obvious differences of preoperative and postoperative ANS position and NLA value were found in both groups. The patients were all recovered uneventfully. Surgical guide templates can enhance clinical accuracy and reduce operative time by facilitating accurate osteotomies. PMID:28658139

  13. [Comparative study of three bonding methods in attaching removable thermoplastic appliances].

    PubMed

    Chu, Kejia; Wang, Haihui; Zheng, Zhijun; Li, Qi

    2015-10-01

    To evaluate the operation time and clinical effect of three types of materials (i.e., total-etching adhesive, self-etching adhesive, resin-modified glass ionomer cement) that are used to bond removable thermoplastic appliances. Thirty malocclusion patients (156 attachments) with removable thermoplastic appliances were randomly divided into three groups, with 10 individuals each. Attachments of groups A and B were bonded using 3M Adper Single Bond 2 and 3M Adper Easy One, respectively; both adhesives utilized 3M Z350 nano composite resin. Attachments of group C was directly bonded using GC Fuji Ortho LC. The operation time of each attachment was recorded. Failure rates of adhesion were evaluated during adhesion, 1 month after treatment, and 6 months after treatment. The operation time of group C was shorter than those of groups A and B (P<0.01). Significant difference of adhesion failure rates was not found among the three groups (P>0.05). No significant difference of adhesion failure rates was also observed in different times of the same group (P>0.05). The attachment stability of the three types of materials achieved satisfactory effects. However, the operation method of resin-modified glass ionomer cement is more concise and suitable for clinical promotion.

  14. Hysteroscopic Endometrial Polypectomy: Clinical and Economic Data in Decision Making.

    PubMed

    Franchini, Mario; Lippi, Giuseppe; Calzolari, Stefano; Giarrè, Giovanna; Gubbini, Giampietro; Catena, Ursula; Di Spiezio Sardo, Attilio; Florio, Pasquale

    To compare the costs of hysteroscopic polypectomy using mechanical and electrosurgical systems in the hospital operating room and an office-based setting. Retrospective cohort study (Canadian Task Force classification II-2). Tertiary referral hospital and center for gynecologic care. Seven hundred and fifty-four women who underwent endometrial polypectomy between January 20, 2015, and April 27, 2016. Hysteroscopic endometrial polypectomy performed in the same-day hospital setting or office setting using one of the following: bipolar electrode, loop electrode, mechanical device, or hysteroscopic tissue removal system. The various costs associated with the 2 clinical settings at Palagi Hospital, Florence, Italy were compiled, and a direct cost comparison was made using an activity-based cost-management system. The costs for using reusable loop electrode resection-16 or loop electrode resection-26 were significantly less expensive than using disposable loop electrode resection-27, the tissue removal system, or bipolar electrode resection (p = .0002). Total hospital costs for polypectomy with all systems were significantly less expensive in an office setting compared with same-day surgery in the hospital setting (p = .0001). Office-based hysteroscopic tissue removal was associated with shorter operative time compared with the other procedures (p = .0002) CONCLUSION: The total cost of hysteroscopic polypectomy is markedly higher when using disposable equipment compared with reusable equipment, both in the hospital operating room and the office setting. Same-day hospital or office-based surgery with reusable loop electrode resection is the most cost-effective approach in each settings, but requires experienced surgeons. Finally, the shorter surgical time should be taken into consideration for patients undergoing vaginal polypectomy in the office setting, owing more to patient comfort than to cost savings. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.

  15. Asymmetry in gait pattern following tibial shaft fractures - a prospective one-year follow-up study of 49 patients.

    PubMed

    Larsen, Peter; Laessoe, Uffe; Rasmussen, Sten; Graven-Nielsen, Thomas; Berre Eriksen, Christian; Elsoe, Rasmus

    2017-01-01

    Despite the high number of studies evaluating the outcomes following tibial shaft fractures, the literature lacks studies including objective assessment of patients' recovery regarding gait pattern. The purpose of the present study was to evaluate whether gait patterns at 6 and 12 months post-operatively following intramedullary nailing of a tibial shaft fracture are different compared with a healthy reference population. The study design was a prospective cohort study. The primary outcome measurement was the gait patterns at 6 and 12 months post-operatively measured with a 6-metre-long pressure-sensitive mat. The mat registers footprints and present gait speed, cadence as well as temporal and spatial parameters of the gait cycle. Gait patterns were compared to a healthy reference population. 49 patients were included with a mean age of 43.1 years (18-79 years). Forty-three patients completed the 12-month follow-up (88%). Gait speed and cadence were significantly increased between the 6- and 12-month follow-up (P<0.001). At 6-month follow-up, patients showed considerable asymmetry in the injured leg compared with the non-injured leg: single-support time 12.8% shorter, swing-time 12.8% longer, step-length 11.9% shorter, and rotation of the foot increased by 32.3%. At the 12-month follow-up, gait asymmetry become almost normalized compared to a healthy reference group. In patients treated by intramedullary nailing following a tibial shaft fracture, gait asymmetry accompanied with slower speed and cadence are common during the first 6 months and become normalized compared with a healthy reference population between 6 and 12 months post-operatively. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. A review on prognostic techniques for non-stationary and non-linear rotating systems

    NASA Astrophysics Data System (ADS)

    Kan, Man Shan; Tan, Andy C. C.; Mathew, Joseph

    2015-10-01

    The field of prognostics has attracted significant interest from the research community in recent times. Prognostics enables the prediction of failures in machines resulting in benefits to plant operators such as shorter downtimes, higher operation reliability, reduced operations and maintenance cost, and more effective maintenance and logistics planning. Prognostic systems have been successfully deployed for the monitoring of relatively simple rotating machines. However, machines and associated systems today are increasingly complex. As such, there is an urgent need to develop prognostic techniques for such complex systems operating in the real world. This review paper focuses on prognostic techniques that can be applied to rotating machinery operating under non-linear and non-stationary conditions. The general concept of these techniques, the pros and cons of applying these methods, as well as their applications in the research field are discussed. Finally, the opportunities and challenges in implementing prognostic systems and developing effective techniques for monitoring machines operating under non-stationary and non-linear conditions are also discussed.

  17. Laparoscopic cholecystectomy versus small incision cholecystectomy in symptomatic gallstones disease.

    PubMed

    Mehrvarz, Shaban; Mohebi, Hassan Ali; Kalantar Motamedi, Mohammad Hosein

    2012-10-01

    To compare the results and outcomes of the laparoscopic cholecystectomy (LC) with the small incision cholecystectomy (SIC). Observational study. Baqiyatallah Hospital, Tehran, Iran, from February 2008 to March 2009. Patients with symptomatic gallstones that were referred and enrolled in the study for LC or SIC. Operation, anaesthesia, analgesics and postoperative care were standardized. The patients were assessed for operation time, postoperative pain, nausea, vomiting, hospital stay, return to work time and complications in the postoperative period on day 1, 1 week, 1 month and 6 months, postoperatively. Of 144 patients, 81 underwent LC and 63 underwent SIC. Both groups were matched for age, gender, BMI, clinical findings and ASA grading. The mean duration of operation was 74 and 62 minutes in the LC and SIC groups, respectively (p = 0.0059). Duration of hospital stay and return to regular activities were shorter after LC compared to SIC. Pain scores, nausea and vomiting were the same in both groups, although the frequency of intra-operative complications were greater in LC compared to SIC. Outcome and complications of SIC were comparable with those of LC.

  18. The effect of dynamic scheduling and routing in a solid waste management system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johansson, Ola M.

    2006-07-01

    Solid waste collection and hauling account for the greater part of the total cost in modern solid waste management systems. In a recent initiative, 3300 Swedish recycling containers have been fitted with level sensors and wireless communication equipment, thereby giving waste collection operators access to real-time information on the status of each container. In this study, analytical modeling and discrete-event simulation have been used to evaluate different scheduling and routing policies utilizing the real-time data. In addition to the general models developed, an empirical simulation study has been performed on the downtown recycling station system in Malmoe, Sweden. From themore » study, it can be concluded that dynamic scheduling and routing policies exist that have lower operating costs, shorter collection and hauling distances, and reduced labor hours compared to the static policy with fixed routes and pre-determined pick-up frequencies employed by many waste collection operators today. The results of the analytical model and the simulation models are coherent, and consistent with experiences of the waste collection operators.« less

  19. Self-motion perception compresses time experienced in return travel.

    PubMed

    Seno, Takeharu; Ito, Hiroyuki; Shoji, Sunaga

    2011-01-01

    It is often anecdotally reported that time experienced in return travel (back to the start point) seems shorter than time spent in outward travel (travel to a new destination). Here, we report the first experimental results showing that return travel time is experienced as shorter than the actual time. This discrepancy is induced by the existence of self-motion perception.

  20. Outcomes and Resource Utilization of Endoscopic Mass-Closure Technique for Laryngeal Clefts.

    PubMed

    Balakrishnan, Karthik; Cheng, Esther; de Alarcon, Alessandro; Sidell, Douglas R; Hart, Catherine K; Rutter, Michael J

    2015-07-01

    To compare resource utilization and clinical outcomes between endoscopic mass-closure and open techniques for laryngeal cleft repair. Case series with chart review. Tertiary academic children's hospital. Pediatric patients undergoing repair for Benjamin-Inglis type 1-3 laryngeal clefts over a 15-year period. All 20 patients undergoing endoscopic repair were included. Eight control patients undergoing open repair were selected using matching by age and cleft type. Demographic, clinical, and resource utilization data were collected. Twenty-eight patients were included (20 endoscopic, 8 open). Mean age, rates of tracheostomy and vocal fold immobility, and distribution of cleft types were not different between the 2 groups (all P > .2). Mean operative time (P = .004) and duration of hospital stay (P < .001) were significantly shorter in the endoscopic group. All repairs were intact in both groups at final postoperative endoscopy. Rates of persistent laryngeal penetration or aspiration on swallow study were not different between groups (P = 1.000), although results were available for only 11 patients. Endoscopic laryngeal cleft repair using a mass-closure technique provides a durable result while requiring significantly shorter operative times and hospital stays than open repair and avoiding the potential morbidity of laryngofissure. However, open repair may allow the simultaneous performance of other airway reconstructive procedures and may be a useful salvage technique when endoscopic repair fails. Postoperative swallowing results require further study. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  1. Transperitoneal approach versus retroperitoneal approach: a meta-analysis of laparoscopic partial nephrectomy for renal cell carcinoma.

    PubMed

    Ren, Tong; Liu, Yan; Zhao, Xiaowen; Ni, Shaobin; Zhang, Cheng; Guo, Changgang; Ren, Minghua

    2014-01-01

    To compare the efficiency and safety of the transperitoneal approaches with retroperitoneal approaches in laparoscopic partial nephrectomy for renal cell carcinoma and provide evidence-based medicine support for clinical treatment. A systematic computer search of PUBMED, EMBASE, and the Cochrane Library was executed to identify retrospective observational and prospective randomized controlled trials studies that compared the outcomes of the two approaches in laparoscopic partial nephrectomy. Two reviewers independently screened, extracted, and evaluated the included studies and executed statistical analysis by using software STATA 12.0. Outcomes of interest included perioperative and postoperative variables, surgical complications and oncological variables. There were 8 studies assessed transperitoneal laparoscopic partial nephrectomy (TLPN) versus retroperitoneal laparoscopic partial nephrectomy (RLPN) were included. RLPN had a shorter operating time (SMD = 1.001,95%confidence interval[CI] 0.609-1.393,P<0.001), a lower estimated blood loss (SMD = 0.403,95%CI 0.015-0.791,P = 0.042) and a shorter length of hospital stay (WMD = 0.936 DAYS,95%CI 0.609-1.263,P<0.001) than TLPN. There were no significant differences between the transperitoneal and retroperitoneal approaches in other outcomes of interest. This meta-analysis indicates that, in appropriately selected patients, especially patients with intraperitoneal procedures history or posteriorly located renal tumors, the RLPN can shorten the operation time, reduce the estimated blood loss and shorten the length of hospital stay. RLPN may be equally safe and be faster compared with the TLPN.

  2. Two new mini-slings compared with transobturator tension-free vaginal tape for treatment of stress urinary incontinence: A 1-year follow-up randomized controlled trial.

    PubMed

    Gaber, Mohamed E; Borg, Tamer; Samour, Hazem; Nawara, Mai; Reda, Ahmed

    2016-12-01

    The aim of this study was to compare the outcome of two single-incision mini-slings (the Contasure-Needleless [C-NDL] and the endopelvic free anchorage) with the standard midurethral transobturator tension-free vaginal tape (TVT-O) procedure. A double blind randomized controlled study was conducted at Ain Shams University Maternity Hospital from August 2014 until July 2015. A total of 209 patients were randomized into three groups. The first group underwent the TVT-O procedure, the second group underwent the endopelvic free anchorage procedure and the third group underwent the C-NDL procedure. Patients were followed up for 12 months in terms of subjective cure, objective cure, and complications rate. After 12 months of follow-up, there were no differences among the three groups in terms of objective cure rate, subjective cure rate, patient satisfaction, or incidence of complications (de novo urge, hemorrhage, infection, and mesh erosion). The C-NDL was associated with a shorter operative time (P < 0.001) and less blood loss (P = 0.021) than the standard TVT-O. The new single-incision mini-slings showed similar efficacy and patient acceptance to that of the standard TVT-O for up to 12 months postoperatively with no difference in the complications rate. The C-NDL is associated with shorter operative time and less blood loss. © 2016 Japan Society of Obstetrics and Gynecology.

  3. [Advantage investigation of totally laparoscopic modified Roux-en-Y reconstruction].

    PubMed

    Liu, Tianzhou; Ma, Zhiming; Sun, Pengda; Li, Jinlong; Fang, Xuedong; Tong, Ti; Zhu, Jiaming

    2016-01-01

    To investigate the clinical advantage of the application of modified Roux-en-Y reconstruction after totally laparoscopic total gastrectomy. Clinical data of 36 patients who underwent totally laparoscopic total gastrectomy with Roux-en-Y reconstruction by one medical team for gastric adenocarcinoma between January 2014 and December 2014 in the Second Hospital of Jilin University were retrospectively analyzed. Patients were divided into classic Roux-en-Y group (CRY, 16 cases) and modified Roux-en-Y group (MRY, 20 cases) according to reconstructive methods. The data concerning the intraoperative and postoperative situation in two groups were compared. Operation was successfully completed in all the cases without conversion to laparotomy. Compared to CRY group, MRY group had shorter mean operative time [(260.9 ± 21.2) min vs. (287.9 ± 19.0) min, P=0.000], shorter mean reconstruction duration [(32.4 ± 9.2] min vs. (45.4 ± 13.2) min, P=0.001] and less intraoperative bleeding [(50.9 ± 23.5) ml vs. (67.0 ± 20.5) ml, P=0.000]. Jejunum mesentery dissection and jejunum resection were not necessary in MRY group. However, there were no significant differences in lymph nodes harvested, time to flatus, hospital stay and postoperative complications between two groups. As compared to classic Roux-en-Y reconstruction, the modified Roux-en-Y reconstruction can simplify the surgical procedures and achieve similar efficacy. It is feasible and safe, and worth further promotion in clinical practice.

  4. The Impact of Surgeon Volume on Perioperative Outcomes in Hysterectomy

    PubMed Central

    Vree, Florentien E. M.; Cohen, Sarah L.; Chavan, Niraj

    2014-01-01

    Background and Objectives: To estimate the effect of surgeon volume on key perioperative outcomes after all modes of hysterectomy. Methods: We performed a review of 1914 hysterectomies performed at a large, academic tertiary-care hospital. Women who underwent abdominal, laparoscopic, vaginal, or robotic hysterectomy for benign non-obstetric indications in 2006, 2009, and 2010 were included. Results: Gynecologic surgeons were categorized according their average annual hysterectomy case volume: low volume (<11 cases per year), intermediate volume (11–50 cases per year), and high-volume (>51 cases per year). Taking all modes of hysterectomy together, surgeries performed by high-volume surgeons required a shorter operative time (155.11 minutes vs 199.19–203.35 minutes, P < .001) and resulted in less estimated blood loss compared with low- and intermediate-volume surgeons (161.09 mL vs 205.58–237.96 mL, P < .001). The 3 surgical volume groups did not differ from each other significantly in the conversion to laparotomy, readmission rate, or incidence of intraoperative or postoperative complications. These findings were maintained when subgroup analyses were performed by type of hysterectomy, with few exceptions. In the subgroup of vaginal hysterectomies by intermediate-volume surgeons, there were slightly more postoperative complications. There were fewer intraoperative complications in laparoscopic/robotic hysterectomies performed by high-volume surgeons, though not statistically significant. Conclusions: Hysterectomies performed by high-volume surgeons at our institution during the 3-year study period were associated with shorter operative times and less estimated blood loss. PMID:24960479

  5. Effect of employment status on length of hospital stay, 30-day readmission and patient reported outcomes after spine surgery.

    PubMed

    Adogwa, Owoicho; Elsamadicy, Aladine A; Fialkoff, Jared; Mehta, Ankit I; Vasquez, Raul A; Cheng, Joseph; Karikari, Isaac O; Bagley, Carlos A

    2017-03-01

    Growing scrutiny has placed hospitals at the center of readmission prevention. The relationship between pre-operative employment status, length of hospital stays (LOS) and 30-day readmission rates after elective spine surgery remains unclear. The medical records of 360 patients (employed: n=174, unemployed: n=70, retired: n=40, disabled: n=76) undergoing elective spine surgery at a major academic medical center were reviewed. Patient demographics, comorbidities, and post-operative complication rates were recorded. All patients had comprehensive 1-year patient reported outcomes (PROs) measures. We hypothesized that employment status is associated with decreased LOS and decreased risk of 30-day readmission after elective spine surgery. All-cause readmissions within 30 days of discharge was the primary outcome variable. Baseline characteristics were similar in all cohorts. There was no difference in operative time, estimated blood loss (EBL), or number of fusion levels between all patient cohorts. There were no significant differences in peri-operative complication rates between patient cohorts. On average, the LOS was shorter for the employed compared to non-employed patients (4.89 vs. 5.26 days). The rate of 30-day readmission was 2-fold greater unemployed compared to employed patients (5.17% vs. 10%). At 1-year after surgery, employed patients were more likely to express functional improvement (change in ODI score) compared to unemployed patients (ODI: employed: 33.80 vs. unemployed: 41.93). Our study suggests that employment status may be associated with shorter duration of hospital stay, lower 30-day readmission rates and greater functional improvement. Future interventions to reduce unplanned hospital readmissions should consider pre-operative employment status.

  6. Quantum mechanical expansion of variance of a particle in a weakly non-uniform electric and magnetic field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, Poh Kam; Kosaka, Wataru; Oikawa, Shun-ichi

    We have solved the Heisenberg equation of motion for the time evolution of the position and momentum operators for a non-relativistic spinless charged particle in the presence of a weakly non-uniform electric and magnetic field. It is shown that the drift velocity operator obtained in this study agrees with the classical counterpart, and that, using the time dependent operators, the variances in position and momentum grow with time. The expansion rate of variance in position and momentum are dependent on the magnetic gradient scale length, however, independent of the electric gradient scale length. In the presence of a weakly non-uniformmore » electric and magnetic field, the theoretical expansion rates of variance expansion are in good agreement with the numerical analysis. It is analytically shown that the variance in position reaches the square of the interparticle separation, which is the characteristic time much shorter than the proton collision time of plasma fusion. After this time, the wavefunctions of the neighboring particles would overlap, as a result, the conventional classical analysis may lose its validity. The broad distribution of individual particle in space means that their Coulomb interactions with other particles become weaker than that expected in classical mechanics.« less

  7. Colorectal cancer surgery in the very elderly patient: a systematic review of laparoscopic versus open colorectal resection.

    PubMed

    Devoto, Laurence; Celentano, Valerio; Cohen, Richard; Khan, Jim; Chand, Manish

    2017-09-01

    Colorectal cancer is the second most common cause of death from neoplastic disease in men and third in women of all ages. Globally, life expectancy is increasing, and consequently, an increasing number of operations are being performed on more elderly patients with the trend set to continue. Elderly patients are more likely to have cardiovascular and pulmonary comorbidities that are associated with increased peri-operative risk. They further tend to present with more locally advanced disease, more likely to obstruct or have disseminated disease. The aim of this review was to investigate the feasibility of laparoscopic colorectal resection in very elderly patients, and whether there are benefits over open surgery for colorectal cancer. A systematic literature search was performed on Medline, Pubmed, Embase and Google Scholar. All comparative studies evaluating patients undergoing laparoscopic versus open surgery for colorectal cancer in the patients population over 85 were included. The primary outcomes were 30-day mortality and 30-day overall morbidity. Secondary outcomes were operating time, time to oral diet, number of retrieved lymph nodes, blood loss and 5-year survival. The search provided 1507 citations. Sixty-nine articles were retrieved for full text analysis, and only six retrospective studies met the inclusion criteria. Overall mortality for elective laparoscopic resection was 2.92% and morbidity 23%. No single study showed a significant difference between laparoscopic and open surgery for morbidity or mortality, but pooled data analysis demonstrated reduced morbidity in the laparoscopic group (p = 0.032). Patients undergoing laparoscopic surgery are more likely to have a shorter hospital stay and a shorter time to oral diet. Elective laparoscopic resection for colorectal cancer in the over 85 age group is feasible and safe and offers similar advantages over open surgery to those demonstrated in patients of younger ages.

  8. Antegrade versus retrograde cerebral perfusion for hemiarch replacement with deep hypothermic circulatory arrest: does it matter? A propensity-matched analysis.

    PubMed

    Ganapathi, Asvin M; Hanna, Jennifer M; Schechter, Matthew A; Englum, Brian R; Castleberry, Anthony W; Gaca, Jeffrey G; Hughes, G Chad

    2014-12-01

    The choice of cerebral perfusion strategy for aortic arch surgery has been debated, and the superiority of antegrade (ACP) or retrograde (RCP) cerebral perfusion has not been shown. We examined the early and late outcomes for ACP versus RCP in proximal (hemi-) arch replacement using deep hypothermic circulatory arrest (DHCA). A retrospective analysis of a prospectively maintained database was performed for all patients undergoing elective and nonelective hemiarch replacement at a single referral institution from June 2005 to February 2013. Total arch cases were excluded to limit the analysis to shorter DHCA times and a more uniform patient population for whom clinical equipoise regarding ACP versus RCP exists. A total of 440 procedures were identified, with 360 (82%) using ACP and 80 (18%) using RCP. The endpoints included 30-day/in-hospital and late outcomes. A propensity score with 1:1 matching of 40 pre- and intraoperative variables was used to adjust for differences between the 2 groups. All 80 RCP patients were propensity matched to a cohort of 80 similar ACP patients. The pre- and intraoperative characteristics were not significantly different between the 2 groups after matching. No differences were found in 30-day/in-hospital mortality or morbidity outcomes. The only significant difference between the 2 groups was a shorter mean operative time in the RCP cohort (P = .01). No significant differences were noted in late survival (P = .90). In proximal arch operations using DHCA, equivalent early and late outcomes can be achieved with RCP and ACP, although the mean operative time is significantly less with RCP, likely owing to avoidance of axillary cannulation. Questions remain regarding comparative outcomes with straight DHCA and lesser degrees of hypothermia. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  9. Novel calcium infusion regimen after parathyroidectomy for renal hyperparathyroidism

    PubMed Central

    Tan, Jih Huei; Tan, Henry Chor Lip; Arulanantham, Sarojah A/P

    2017-01-01

    Abstract Aim Calcium infusion is used after parathyroid surgery for renal hyperparathyroidism to treat postoperative hypocalcaemia. We compared a new infusion regimen to one commonly used in Malaysia based on 2003 K/DOQI guidelines. Methods Retrospective data on serum calcium and infusion rates was collected from 2011–2015. The relationship between peak calcium efflux (PER) and time was determined using a scatterplot and linear regression. A comparison between regimens was made based on treatment efficacy (hypocalcaemia duration, total infusion amount and time) and calcium excursions (outside target range, peak and trough calcium) using bar charts and an unpaired t‐test. Results Fifty‐one and 34 patients on the original and new regimens respectively were included. Mean PER was lower (2.16 vs 2.56 mmol/h; P = 0.03) and occurred earlier (17.6 vs 23.2 h; P = 0.13) for the new regimen. Both scatterplot and regression showed a large correlation between PER and time (R‐square 0.64, SE 1.53, P < 0.001). The new regimen had shorter period of hypocalcaemia (28.9 vs 66.4 h, P = 0.04), and required less calcium infusion (67.7 vs 127.2 mmol, P = 0.02) for a shorter duration (57.3 vs 102.9 h, P = 0.001). Calcium excursions, peak and trough calcium were not significantly different between regimens. Early postoperative high excursions occurred when the infusion was started in spite of elevated peri‐operative calcium levels. Conclusion The new infusion regimen was superior to the original in that it required a shorter treatment period and resulted in less hypocalcaemia. We found that early aggressive calcium replacement is unnecessary and raises the risk of rebound hypercalcemia. PMID:26952689

  10. Computer-assisted versus conventional free fibula flap technique for craniofacial reconstruction: an outcomes comparison.

    PubMed

    Seruya, Mitchel; Fisher, Mark; Rodriguez, Eduardo D

    2013-11-01

    There has been rising interest in computer-aided design/computer-aided manufacturing for preoperative planning and execution of osseous free flap reconstruction. The purpose of this study was to compare outcomes between computer-assisted and conventional fibula free flap techniques for craniofacial reconstruction. A two-center, retrospective review was carried out on patients who underwent fibula free flap surgery for craniofacial reconstruction from 2003 to 2012. Patients were categorized by the type of reconstructive technique: conventional (between 2003 and 2009) or computer-aided design/computer-aided manufacturing (from 2010 to 2012). Demographics, surgical factors, and perioperative and long-term outcomes were compared. A total of 68 patients underwent microsurgical craniofacial reconstruction: 58 conventional and 10 computer-aided design and manufacturing fibula free flaps. By demographics, patients undergoing the computer-aided design/computer-aided manufacturing method were significantly older and had a higher rate of radiotherapy exposure compared with conventional patients. Intraoperatively, the median number of osteotomies was significantly higher (2.0 versus 1.0, p=0.002) and the median ischemia time was significantly shorter (120 minutes versus 170 minutes, p=0.004) for the computer-aided design/computer-aided manufacturing technique compared with conventional techniques; operative times were shorter for patients undergoing the computer-aided design/computer-aided manufacturing technique, although this did not reach statistical significance. Perioperative and long-term outcomes were equivalent for the two groups, notably, hospital length of stay, recipient-site infection, partial and total flap loss, and rate of soft-tissue and bony tissue revisions. Microsurgical craniofacial reconstruction using a computer-assisted fibula flap technique yielded significantly shorter ischemia times amidst a higher number of osteotomies compared with conventional techniques. Therapeutic, III.

  11. Techniques for caesarean section.

    PubMed

    Hofmeyr, G J; Mathai, M; Shah, A; Novikova, N

    2008-01-23

    Rates of caesarean section (CS) have been rising globally. It is important to use the most effective and safe technique. To compare the effects of complete methods of caesarean section; and to summarise the findings of reviews of individual aspects of caesarean section technique. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (August 2007), the Cochrane Central Register of Controlled Trials (The Cochrane Library 2007, Issue 3) and reference lists of identified papers. Randomised controlled trials of intention to perform caesarean section using different techniques. Two review authors independently assessed studies and extracted data. 'Joel-Cohen based' compared with Pfannenstiel CS was associated with: less blood loss, (five trials, 481 women; weighted mean difference (WMD) -64.45 ml; 95% confidence interval (CI) -91.34 to -37.56 ml); shorter operating time (five trials, 581 women; WMD -18.65; 95% CI -24.84 to -12.45 minutes); postoperatively, reduced time to oral intake (five trials, 481 women; WMD -3.92; 95% CI -7.13 to -0.71 hours); less fever (eight trials, 1412 women; relative risk (RR) 0.47; 95% CI 0.28 to 0.81); shorter duration of postoperative pain (two comparisons from one trial, 172 women; WMD -14.18 hours; 95% CI -18.31 to -10.04 hours); fewer analgesic injections (two trials, 151 women; WMD -0.92; 95% CI -1.20 to -0.63); and shorter time from skin incision to birth of the baby (five trials, 575 women; WMD -3.84 minutes; 95% CI -5.41 to -2.27 minutes). Serious complications and blood transfusions were too few for analysis.Misgav-Ladach compared with the traditional method (lower midline abdominal incision) was associated with reduced: blood loss (339 women; WMD -93.00; 95% CI -132.72 to -53.28 ml); operating time (339 women; WMD-7.30; 95% CI -8.32 to -6.28 minutes); time to mobilisation (339 women; WMD -16.06; 95% CI -18.22 to -13.90 hours); and length of postoperative stay for the mother (339 women; WMD -0.82; 95% CI -1.08 to -0.56 days). Misgav-Ladach compared with modified Misgav-Ladach methods was associated with a longer time from skin incision to birth of the baby (116 women; WMD 2.10; 95% CI 1.10 to 3.10 minutes). 'Joel-Cohen based' methods have advantages compared to Pfannenstiel and to traditional (lower midline) CS techniques, which could translate to savings for the health system. However, these trials do not provide information on mortality and serious or long-term morbidity such as morbidly adherent placenta and scar rupture.

  12. Lean management in academic surgery.

    PubMed

    Collar, Ryan M; Shuman, Andrew G; Feiner, Sandra; McGonegal, Amy K; Heidel, Natalie; Duck, Mary; McLean, Scott A; Billi, John E; Healy, David W; Bradford, Carol R

    2012-06-01

    Lean is a management system designed to enhance productivity by eliminating waste. Surgical practice offers many opportunities for improving efficiency. Our objective was to determine whether systematic implementation of lean thinking in an academic otolaryngology operating room improves efficiency and profitability and preserves team morale and educational opportunities. In an 18-month prospective quasi-experimental study, a multidisciplinary task force systematically implemented lean thinking within an otolaryngology operating room of an academic health system. Operating room turnover time and turnaround time were measured during a baseline period; an observer-effect period in which workers were made aware that their efficiency was being measured but before implementing lean changes; and an intervention period after redesign principles had been used. The impact on teamwork, morale, and surgical resident education were measured during the baseline and intervention periods through validated surveys. A profit model was applied to estimate the financial implications of the study. There was no difference between the baseline and observer-effect periods of the study for turnover time (p = 0.98) or turnaround time (p = 0.20). During the intervention period, the mean turnover time and turnaround time were significantly shorter than during the baseline period (29 vs 38 minutes; p < 0.001 and 69 vs 89 minutes; p < 0.001, respectively). The composite morale score suggested improved morale after implementation (p = 0.011). Educational metrics were unchanged before and after implementation. The annual opportunity revenue for the involved operating room is $330,000; when extrapolated throughout the operating rooms, lean thinking could create 6,500 hours of capacity annually. Application of lean management techniques to a single operating room and surgical service improved operating room efficiency and morale, sustained resident education, and can provide considerable financial gains when scaled to an entire academic surgical suite. Copyright © 2012. Published by Elsevier Inc.

  13. Comparison between the Effects of Rocuronium, Vecuronium, and Cisatracurium Using Train-of-Four and Clinical Tests in Elderly Patients

    PubMed Central

    Sagir, Ozlem; Yucesoy Noyan, Funda; Koroglu, Ahmet; Cicek, Muslum; Ilksen Toprak, Huseyin

    2013-01-01

    Background Postoperative residual blockade, longer duration of action for neuromuscular blockade, and slower recovery were relatively common in elderly patients. Objectives We aimed to investigate the safety of train-of-four ratio and clinical tests in the assessment of patient recovery, and to determine the effects of the rocuronium, vecuronium, and cisatracurium on intubation, extubation and recovery times in elderly patients undergoing abdominal surgery. Patients and Methods After obtaining institutional approval and informed consent, 60 patients over 60 years old and undergoing elective abdominal operations were included in this double-blind, randomized clinical trial. Following a standard anesthesia induction, 0.6mg kg-1 rocuronium, 0.1mg kg-1 vecuronium, and 0.1mg kg-1 cisatracurium were administered to the patients in Group R, Group V, and Group C, respectively. Train-of-four (TOF) ratios were recorded at 10-minute intervals during and after the operation. Modified Aldrete Score (MAS) and clinical tests were recorded in the recovery room at 10-minute intervals. In addition, intubation and extubation times, duration of recovery room stay, and any complications were recorded. Results Intubation time was found to be shorter in Group R than that in Groups V and C (P ˂ 0.001). Times to positive visual disturbances and grip strength tests were shorter in Group C than that in Group V (P = 0.016 and P = 0.011, respectively). In Group R and group C, time to TOF ≥ 0.9 was significantly longer than all positive clinical test times except grip strength (P < 0.05). Conclusions We hold the opinion that cisatracurium is safer in elderly patients compared to other drugs. We also concluded that the usage of TOF ratio together with clinical tests is suitable for assessment of neuromuscular recovery in these patients. PMID:24223350

  14. Comparison of Early and Delayed Open Reduction and Internal Fixation for Treating Closed Tibial Pilon Fractures.

    PubMed

    Tang, Xin; Liu, Lei; Tu, Chong-qi; Li, Jian; Li, Qi; Pei, Fu-xing

    2014-07-01

    The timing of surgery for osteosynthesis of type C pilon (AO/OTA) fractures remains controversial. The aim of this study was to determine the outcome of early and delayed open reduction and internal fixation (ORIF) for treating closed type C pilon fractures. Forty-six patients with closed type C pilon fractures matched according to age, gender, soft tissue conditions, and fracture pattern were divided into group A (early group: underwent surgery within 36 hours of the injury) or group B (delayed group: underwent surgery 10 days to 3 weeks postinjury after the soft tissue swelling subsided). In the delayed group, 9 patients were treated first by temporary external fixation. All the closed fractures were managed by ORIF with locking plates. At follow-up, the clinical and radiographic results were retrospectively analyzed. The mean follow-up time was 25.8 months (range, 14 to 48 months) in group A and 26.0 months (range, 15 to 44 months) in group B. There was no significant difference (P > .05) between the 2 groups regarding the rate of soft tissue complication, the rate of fracture union, and the final functional score. The patients in group A had a significantly shorter mean time to fracture union (21.5 ± 4.0 weeks vs 23.3 ± 3.7 weeks, P < .05), operating time (84.3 ± 12.1 months vs 100.6 ± 13.7 months, P < .01), and hospital stay (7.6 ± 2.6 days vs 15.2 ± 4.2 days, P < .01). If soft tissue conditions are acceptable, early ORIF for treating closed type C pilon fractures can be safe and effective, with similar rates of wound complication, fracture union, and final good functional recovery but shorter operative time, union time, and hospital stay. These results favorably compare with delayed ORIF treatment. Level III, retrospective comparative study. © The Author(s) 2014.

  15. Continuous bind-and-elute protein A capture chromatography: Optimization under process scale column constraints and comparison to batch operation.

    PubMed

    Kaltenbrunner, Oliver; Diaz, Luis; Hu, Xiaochun; Shearer, Michael

    2016-07-08

    Recently, continuous downstream processing has become a topic of discussion and analysis at conferences while no industrial applications of continuous downstream processing for biopharmaceutical manufacturing have been reported. There is significant potential to increase the productivity of a Protein A capture step by converting the operation to simulated moving bed (SMB) mode. In this mode, shorter columns are operated at higher process flow and corresponding short residence times. The ability to significantly shorten the product residence time during loading without appreciable capacity loss can dramatically increase productivity of the capture step and consequently reduce the amount of Protein A resin required in the process. Previous studies have not considered the physical limitations of how short columns can be packed and the flow rate limitations due to pressure drop of stacked columns. In this study, we are evaluating the process behavior of a continuous Protein A capture column cycling operation under the known pressure drop constraints of a compressible media. The results are compared to the same resin operated under traditional batch operating conditions. We analyze the optimum system design point for a range of feed concentrations, bed heights, and load residence times and determine achievable productivity for any feed concentration and any column bed height. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:938-948, 2016. © 2016 American Institute of Chemical Engineers.

  16. Assessment of the SonixGPS system for its application in real-time ultrasonography navigation-guided percutaneous nephrolithotomy for the treatment of complex kidney stones.

    PubMed

    Li, Xiang; Long, Qingzhi; Chen, Xingfa; He, Dalin; He, Hui

    2017-04-01

    SonixGPS is a novel real-time ultrasonography navigation technology, which has been demonstrated to promote accuracy of puncture in surgical operations. The aim of this study is to evaluate its application in guiding the puncture during percutaneous nephrolithotomy (PCNL). We retrospectively reviewed our experience in treating a total of 74 patients with complex kidney stones with PCNL, in which puncture in 37 cases were guided by SonixGPS system, while the other 37 by conventional ultrasound. The effectiveness of operation was evaluated in terms of stone clearance rate, operation time, time to successful puncture, number of attempts for successful puncture and hospital stay. The safety of operation was examined by evaluating postoperative complications. Our retrospective review showed that although there were no significant differences in stone clearance rates between the groups, SonixGPS guidance resulted in more puncture accuracy with shorter puncture time and higher successful puncture rate. Under the help of SonixGPS, most patients (92 %) had no or just mild complications, compared to that (73 %) in conventional ultrasound group. Post-operative decrease of hemoglobin in SonixGPS group was 13.79 (7-33) mg/dl, significantly lower than that 20.97 (8-41) mg/dl in conventional ultrasound group. Our experience demonstrates that SonixGPS is superior to conventional ultrasound in guiding the puncture in PCNL for the treatment of complex kidney stone.

  17. Use of early gastrografin small bowel follow-through in small bowel obstruction management.

    PubMed

    Galardi, Nicholas; Collins, Jay; Friend, Kara

    2013-08-01

    Small bowel follow-through (SBFT) is a diagnostic tool commonly used in the management of patients with small bowel obstruction (SBO). This study assessed whether early implementation of Gastrografin SBFT would reduce the time to resolution of the SBO and decrease the time to operative intervention. In this retrospective chart review, 103 patients with the clinical diagnosis of adhesive SBO were evaluated. End points of the study were resolution of SBO with nonoperative management or operative intervention. The patient group that had received a SBFT was then compared with those that did not receive a SBFT. There were 103 patients with adhesive SBO who met inclusion criteria for this study. Seventy-two of 103 patients had undergone Gastrografin SBFT and 31 did not. In the SBFT group, mean time to the operating room was 1.0 days after SBFTs, whereas in the group that did not receive SBFT, it was 3.7 days (P < 0.0001). Mean time to nonoperative resolution of SBO in the SBFT group was 1.8 days and 4.7 days in the no SBFT group (P < 0.0001). There were no Gastrografin-related complications. Obtaining Gastrografin SBFT in patients with adhesive SBO leads to both a shorter time in identifying the need for operative intervention and to resolution of SBO with nonoperative management. SBFT seems to be a more definitive assessment of whether an SBO will resolve on its own or if operative intervention is necessary.

  18. Robot-assisted partial nephrectomy: continued refinement of outcomes beyond the initial learning curve.

    PubMed

    Paulucci, David J; Abaza, Ronney; Eun, Daniel D; Hemal, Ashok K; Badani, Ketan K

    2017-05-01

    To evaluate trends in peri-operative outcomes of 250 consecutive cases beyond the initial learning curve (LC) of robot-assisted partial nephrectomy (RAPN) among multiple surgeons. A multi-institutional database was used to evaluate trends in patient demographics (e.g. age, gender, comorbidities), tumour characteristics (e.g. size, complexity) and peri-operative outcomes (e.g. warm ischaemia time [WIT], operating time, complications, estimated blood loss [EBL], trifecta achievement) in consecutive cases 50-300 (n = 960) from 2008 to 2016 among four experienced surgeons. Trends in outcomes were assessed using multivariable regression models adjusted for demographic and tumour-specific variables. Outcomes for cases 50-99 were compared with those for cases 250-300. In the study period RAPN was increasingly performed in patients with larger tumours (β = 0.001, P = 0.048), hypertension (odds ratio [OR] 1.003; P = 0.008) diabetes (OR 1.003; P = 0.025) and previous abdominal surgery (OR 1.003; P = 0.006). Surgeon experience was associated with more trifecta achievement (OR 1.006; P < 0.001), shorter WIT (β = -0.036, P < 0.001), less EBL (β = -0.154, P = 0.009), fewer blood transfusions (OR 0.989, P = 0.024) and a reduced length of hospital stay (β = -0.002, P = 0.002), but not with operating time (P = 0.243), complications (P = 0.587) or surgical margin status (P = 0.102). Tumour size and WIT in cases 50-99 vs 250-300 were 2.7 vs 3.2 cm (P = 0.001) and 21.4 vs 16.2 min (P < 0.001), respectively. Refinement of RAPN outcomes, concomitant with the treatment of a patient population with larger tumours and more comorbidities, occurs after the initial LC is reached. Although RAPN can consistently be performed safely with acceptable outcomes after a small number of cases, improvement in trifecta achievement, WIT, EBL, blood transfusions and a shorter hospitalization continues to occur up to 300 procedures. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  19. Keyhole approach for repair of congenital duodenal obstruction.

    PubMed

    Kozlov, Y; Novogilov, V; Yurkov, P; Podkamenev, A; Weber, I; Sirkin, N

    2011-03-01

    We report on our experience of repair of congenital duodenal obstruction using a circumumbilical incision. The aim of this report is to describe how a Bianchi approach provides a safe and invisible alternative to transverse abdominal incision for the repair of duodenal atresia. Between January 2005 and December 2009, we treated 13 cases with congenital duodenal obstruction using a circumumbilical incision (Group I) and 14 cases with this condition repaired using a standard transverse right upper abdominal incision (Group II). Surgical procedures included a diamond-shaped duodenoduodenostomy as originally described by Kimura and standard duodenal web excision. The circumumbilical incision utilized at our institution is a classic Bianchi procedure. The 2 groups were compared with regard to patient demographics, operative reports and postoperative outcomes. There were no differences in preoperative parameters such as gestational age, age at surgery, or body weight at operation between the 2 groups. The circumumbilical cohort and transverse incision cohort had similar rates of congenital anomalies (61.54% vs. 64.29%), Kimura diamond-shaped anastomosis (61.54% vs. 64.29%) with only a slight female predominance in Group I. The mean operating time in Group I was 65.0 min while mean duration of the operation in Group II was 64.64 min. The difference between groups was statistically not significant (p>0.05). The mean time to full enteral feeding for patients with an umbilical incision was significantly shorter (p<0.0001) compared to patients with a standard incision (6.92 days vs. 11.86 days). Mean postoperative hospital stay was longer for patients in Group II (19.71 days vs. 12.38 days; p<0.0001). The postoperative course was uneventful for all patients. There were no intra- or postoperative complications. We report on a first series comparing umbilical and transverse right upper abdominal incision for the treatment of congenital duodenal obstruction. Our results suggest that an umbilical incision offers all the benefits of a minimal access approach, including earlier feeding and shorter times to discharge. We consider our approach an intermediate step, with laparoscopy likely to become the "gold standard" for the treatment of congenital duodenal obstruction. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Comparison of totally laparoscopic total gastrectomy using an endoscopic linear stapler with laparoscopic-assisted total gastrectomy using a circular stapler in patients with gastric cancer: A single-center experience.

    PubMed

    Gong, Chung Sik; Kim, Byung Sik; Kim, Hee Sung

    2017-12-28

    To evaluate the safety and efficacy of totally laparoscopic total gastrectomy (TLTG) with esophagojejunostomy using a linear stapler compared with laparoscopic-assisted total gastrectomy (LATG) using a circular stapler in gastric cancer patients. We retrospectively reviewed 687 patients who underwent laparoscopic total gastrectomy for gastric cancer at a single institution from August 2008 to August 2014. The patients were divided into two groups according to the type of operation: 421 patients underwent TLTG and 266 underwent LATG. Clinicopathologic characteristics and surgical outcomes in the two groups were compared and analyzed. The TLTG group had higher mean ages at the time of operation (57.78 ± 11.20 years and 55.69 ± 11.96 years, P = 0.020) and more histories of abdominal surgery (20.2% and 12.4%, P = 0.008) compared with the LATG group. Surgical outcomes such as intraoperative and postoperative transfusions, combined operations, pain scores and administration of analgesics, and complications were similar between the two groups. However, compared with the LATG group, the TLTG group required a shorter operation time (149 min vs 170 min, P < 0.001), had lower postoperative hematocrit change (3.49% vs 4.04%, P = 0.002), less intraoperative events (3.1% vs 10.2%, P < 0.001), less intraoperative anastomosis events (2.4% vs 7.1%, P = 0.003), faster postoperative recovery such as median time to first flatus (3.30 d vs 3.60 d, P < 0.001), faster median commencement of soft diet (4.30 d vs 4.60 d, P < 0.001) and shorter length of postoperative hospital stay (6.75 d vs 7.02 d, P = 0.005). The intracorporeal method for reconstruction of esophagojejunostomy using a linear stapler may be considered a feasible procedure comparing with extracorporeal anastomosis using circular stapler because TLTG is simpler and more straightforward than LATG. Therefore, TLTG can be recommended as an appropriate procedure for gastric cancer.

  1. Comparison of totally laparoscopic total gastrectomy using an endoscopic linear stapler with laparoscopic-assisted total gastrectomy using a circular stapler in patients with gastric cancer: A single-center experience

    PubMed Central

    Gong, Chung Sik; Kim, Byung Sik; Kim, Hee Sung

    2017-01-01

    AIM To evaluate the safety and efficacy of totally laparoscopic total gastrectomy (TLTG) with esophagojejunostomy using a linear stapler compared with laparoscopic-assisted total gastrectomy (LATG) using a circular stapler in gastric cancer patients. METHODS We retrospectively reviewed 687 patients who underwent laparoscopic total gastrectomy for gastric cancer at a single institution from August 2008 to August 2014. The patients were divided into two groups according to the type of operation: 421 patients underwent TLTG and 266 underwent LATG. Clinicopathologic characteristics and surgical outcomes in the two groups were compared and analyzed. RESULTS The TLTG group had higher mean ages at the time of operation (57.78 ± 11.20 years and 55.69 ± 11.96 years, P = 0.020) and more histories of abdominal surgery (20.2% and 12.4%, P = 0.008) compared with the LATG group. Surgical outcomes such as intraoperative and postoperative transfusions, combined operations, pain scores and administration of analgesics, and complications were similar between the two groups. However, compared with the LATG group, the TLTG group required a shorter operation time (149 min vs 170 min, P < 0.001), had lower postoperative hematocrit change (3.49% vs 4.04%, P = 0.002), less intraoperative events (3.1% vs 10.2%, P < 0.001), less intraoperative anastomosis events (2.4% vs 7.1%, P = 0.003), faster postoperative recovery such as median time to first flatus (3.30 d vs 3.60 d, P < 0.001), faster median commencement of soft diet (4.30 d vs 4.60 d, P < 0.001) and shorter length of postoperative hospital stay (6.75 d vs 7.02 d, P = 0.005). CONCLUSION The intracorporeal method for reconstruction of esophagojejunostomy using a linear stapler may be considered a feasible procedure comparing with extracorporeal anastomosis using circular stapler because TLTG is simpler and more straightforward than LATG. Therefore, TLTG can be recommended as an appropriate procedure for gastric cancer. PMID:29358863

  2. Efficacy and safety of interscalene block combined with general anesthesia for arthroscopic shoulder surgery: A meta-analysis.

    PubMed

    Yan, Siyi; Zhao, Yanjun; Zhang, Huan

    2018-06-01

    There is controversy regarding the efficacy and safety of using interscalene block (ISB) combined with general anesthesia (GA) for arthroscopic shoulder surgery. Our meta-analysis was undertaken to evaluate the utility of this approach. We searched the PubMed, Cochrane Library, EMBASE, CNKI, VIP and ClinicalTrials.gov databases for randomized controlled trials. The primary endpoint was extubation time. Secondary endpoints included intraoperative heart rate, pain scores on the day of and 1 day after the operation, intraoperative systolic blood pressure and adverse events. Ten RCTs involving 746 patients undergoing arthroscopic shoulder surgery met inclusion criteria. Compared with GA alone, ISB + GA was associated with a shorter extubation time(WMD = -6.13; 95% CI = -8.68 to -3.57; P < 0.00001; I 2  = 94%), a lower pain score on the day of the operation (WMD = -2.46; 95% CI = -4.53 to -0.40; P = 0.02; I 2  = 97%), a lower pain score 1 day after the operation (WMD = -1.49; 95% CI = -2.46 to -0.52; P = 0.003; I 2  = 88%), a lower intraoperative systolic blood pressure (WMD = -12.64; 95% CI = -20.90 to -4.39; P = 0.003; I 2  = 95%), a lower heart rate (WMD = -8.81; 95% CI = -15.34 to -2.28; P = 0.008; I 2  = 95%) and a lower incidence of adverse events (RR = 0.31; 95% CI = 0.15-0.66; P = 0.002; I 2  = 32%). In patients undergoing arthroscopic shoulder surgery, ISB + GA is associated with a lower heart rate, lower pain scores on the day of and 1 day after the operation, a lower intraoperative systolic blood pressure, a shorter extubation time and a lower incidence of adverse events compared with GA alone. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Ensemble Sampling vs. Time Sampling in Molecular Dynamics Simulations of Thermal Conductivity

    DOE PAGES

    Gordiz, Kiarash; Singh, David J.; Henry, Asegun

    2015-01-29

    In this report we compare time sampling and ensemble averaging as two different methods available for phase space sampling. For the comparison, we calculate thermal conductivities of solid argon and silicon structures, using equilibrium molecular dynamics. We introduce two different schemes for the ensemble averaging approach, and show that both can reduce the total simulation time as compared to time averaging. It is also found that velocity rescaling is an efficient mechanism for phase space exploration. Although our methodology is tested using classical molecular dynamics, the ensemble generation approaches may find their greatest utility in computationally expensive simulations such asmore » first principles molecular dynamics. For such simulations, where each time step is costly, time sampling can require long simulation times because each time step must be evaluated sequentially and therefore phase space averaging is achieved through sequential operations. On the other hand, with ensemble averaging, phase space sampling can be achieved through parallel operations, since each ensemble is independent. For this reason, particularly when using massively parallel architectures, ensemble sampling can result in much shorter simulation times and exhibits similar overall computational effort.« less

  4. Mentor Tutoring: An Efficient Method for Teaching Laparoscopic Colorectal Surgical Skills in a General Hospital.

    PubMed

    Ichikawa, Nobuki; Homma, Shigenori; Yoshida, Tadashi; Ohno, Yosuke; Kawamura, Hideki; Wakizaka, Kazuki; Nakanishi, Kazuaki; Kazui, Keizo; Iijima, Hiroaki; Shomura, Hiroki; Funakoshi, Tohru; Nakano, Shiro; Taketomi, Akinobu

    2017-12-01

    We retrospectively assessed the efficacy of our mentor tutoring system for teaching laparoscopic colorectal surgical skills in a general hospital. A series of 55 laparoscopic colectomies performed by 1 trainee were evaluated. Next, the learning curves for high anterior resection performed by the trainee (n=20) were compared with those of a self-trained surgeon (n=19). Cumulative sum analysis and multivariate regression analyses showed that 38 completed cases were needed to reduce the operative time. In high anterior resection, the mean operative times were significantly shorter after the seventh average for the tutored surgeon compared with that for the self-trained surgeon. In cumulative sum charting, the curve reached a plateau by the seventh case for the tutored surgeon, but continued to increase for the self-trained surgeon. Mentor tutoring effectively teaches laparoscopic colorectal surgical skills in a general hospital setting.

  5. Enhanced mesophilic anaerobic digestion of food waste by thermal pretreatment: Substrate versus digestate heating.

    PubMed

    Ariunbaatar, Javkhlan; Panico, Antonio; Yeh, Daniel H; Pirozzi, Francesco; Lens, Piet N L; Esposito, Giovanni

    2015-12-01

    Food waste (FW) represents a source of high potential renewable energy if properly treated with anaerobic digestion (AD). Pretreating the substrates could yield a higher biomethane production in a shorter time. In this study, the effects of thermal (heating the FW in a separate chamber) and thermophilic (heating the full reactor content containing both FW and inoculum) pretreatments at 50, 60, 70 and 80°C prior to mesophilic AD were studied through a series of batch experiments. Pretreatments at a lower temperature (50°C) and a shorter time (<12h) had a positive effect on the AD process. The highest enhancement of the biomethane production with an increase by 44-46% was achieved with a thermophilic pretreatment at 50°C for 6-12h or a thermal pretreatment at 80°C for 1.5h. Thermophilic pretreatments at higher temperatures (>55°C) and longer operating times (>12h) yielded higher soluble chemical oxygen demand (CODs), but had a negative effect on the methanogenic activity. The thermal pretreatments at the same conditions resulted in a lower solubilization of COD. Based on net energy calculations, the enhanced biomethane production is sufficient to heat up the FW for the thermal, but not for the thermophilic pretreatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Distributed measurement of acoustic vibration location with frequency multiplexed phase-OTDR

    NASA Astrophysics Data System (ADS)

    Iida, Daisuke; Toge, Kunihiro; Manabe, Tetsuya

    2017-07-01

    All-fiber distributed vibration sensing is attracting attention in relation to structural health monitoring because it is cost effective, offers high coverage of the monitored area and can detect various structural problems. And in particular the demand for high-speed vibration sensing operating at more than 10 kHz has increased because high frequency vibration indicates high energy and severe trouble in the monitored object. Optical fiber vibration sensing with phase-sensitive optical time domain reflectometry (phase-OTDR) has long been studied because it can be used for distributed vibration sensing in optical fiber. However, pulse reflectometry such as OTDR cannot measure high-frequency vibration whose cycle is shorter than the repetition time of the OTDR. That is, the maximum detectable frequency depends on fiber length. In this paper, we describe a vibration sensing technique with frequency-multiplexed OTDR that can detect the entire distribution of a high-frequency vibration thus allowing us to locate a high-speed vibration point. We can measure the position, frequency and dynamic change of a high-frequency vibration whose cycle is shorter than the repetition time. Both frequency and position are visualized simultaneously for a 5-km fiber with an 80-kHz frequency response and a 20-m spatial resolution.

  7. Comparing Outcomes and Cost of 3 Surgical Treatments for Sagittal Synostosis: A Retrospective Study Including Procedure-Related Cost Analysis.

    PubMed

    Garber, Sarah T; Karsy, Michael; Kestle, John R W; Siddiqi, Faizi; Spanos, Stephen P; Riva-Cambrin, Jay

    2017-10-01

    Neurosurgical techniques for repair of sagittal synostosis include total cranial vault (TCV) reconstruction, open sagittal strip (OSS) craniectomy, and endoscopic strip (ES) craniectomy. To evaluate outcomes and cost associated with these 3 techniques. Via retrospective chart review with waiver of informed consent, the last consecutive 100 patients with sagittal synostosis who underwent each of the 3 surgical correction techniques before June 30, 2013, were identified. Clinical, operative, and process of care variables and their associated specific charges were analyzed along with overall charge. The study included 300 total patients. ES patients had fewer transfusion requirements (13% vs 83%, P < .001) than TCV patients, fewer days in intensive care (0.3 vs 1.3, P < .001), and a shorter overall hospital stay (1.8 vs 4.2 d, P < .001), and they required fewer revisions (1% vs 6%, P = .05). The mean charge for the endoscopic procedure was $21 203, whereas the mean charge for the TCV reconstruction was $45 078 (P < .001). ES patients had more preoperative computed tomography scans (66% vs 44%, P = .003) than OSS patients, shorter operative times (68 vs 111 min, P < .001), and required fewer revision procedures (1% vs 8%, P < .001). The mean charge for the endoscopic procedure was $21 203 vs $20 535 for the OSS procedure (P = .62). The ES craniectomy for sagittal synostosis appeared to have less morbidity and a potential cost savings compared with the TCV reconstruction. The charges were similar to those incurred with OSS craniectomy, but patients had a shorter length of stay and fewer revisions. Copyright © 2017 by the Congress of Neurological Surgeons

  8. A population-based study comparing laparoscopic and robotic outcomes in colorectal surgery.

    PubMed

    Tam, Michael S; Kaoutzanis, Christodoulos; Mullard, Andrew J; Regenbogen, Scott E; Franz, Michael G; Hendren, Samantha; Krapohl, Greta; Vandewarker, James F; Lampman, Richard M; Cleary, Robert K

    2016-02-01

    Current data addressing the role of robotic surgery for the management of colorectal disease are primarily from single-institution and case-matched comparative studies as well as administrative database analyses. The purpose of this study was to compare minimally invasive surgery outcomes using a large regional protocol-driven database devoted to surgical quality, improvement in patient outcomes, and cost-effectiveness. This is a retrospective cohort study from the prospectively collected Michigan Surgical Quality Collaborative registry designed to compare outcomes of patients who underwent elective laparoscopic, hand-assisted laparoscopic, and robotic colon and rectal operations between July 1, 2012 and October 7, 2014. We adjusted for differences in baseline covariates between cases with different surgical approaches using propensity score quintiles modeled on patient demographics, general health factors, diagnosis, and preoperative co-morbidities. The primary outcomes were conversion rates and hospital length of stay. Secondary outcomes included operative time, and postoperative morbidity and mortality. A total of 2735 minimally invasive colorectal operations met inclusion criteria. Conversion rates were lower with robotic as compared to laparoscopic operations, and this was statistically significant for rectal resections (colon 9.0 vs. 16.9%, p < 0.06; rectum 7.8 vs. 21.2%, p < 0.001). The adjusted length of stay for robotic colon operations (4.00 days, 95% CI 3.63-4.40) was significantly shorter compared to laparoscopic (4.41 days, 95% CI 4.17-4.66; p = 0.04) and hand-assisted laparoscopic cases (4.44 days, 95% CI 4.13-4.78; p = 0.008). There were no significant differences in overall postoperative complications among groups. When compared to conventional laparoscopy, the robotic platform is associated with significantly fewer conversions to open for rectal operations, and significantly shorter length of hospital stay for colon operations, without increasing overall postoperative morbidity. These findings and the recent upgrades in minimally invasive technology warrant continued evaluation of the role of the robotic platform in colorectal surgery.

  9. Laparosopic hand-assisted living donor nephrectomy: the Niguarda experience.

    PubMed

    Maione, G; Sansalone, C V; Aseni, P; De Roberto, A; Soldano, S; Mangoni, I; Perrino, L; Minetti, E; Civati, G

    2005-01-01

    Perioperative donor morbidity, a barrier to living organ donation, may be mitigated by the laparoscopic approach. From September 2002 to September 2004, 15 living donors, of ages ranging from 36 to 59 years, underwent laparoscopic nephrectomy. We used a hand-assisted device to increase the safety of the procedure. The average operating time was 200 minutes. The average blood loss was about 100 mL. The patients resumed oral intake and started walking within 1 day. The average postoperative hospital stay was 6 days. Although laparoscopic operating times were longer than those for traditional surgery, we showed benefits to the laparoscopic donor to be less postoperative pain, better cosmesis, shorter recovery time, and faster return to normal activities. We therefore consider laparoscopic nephrectomy a good alternative to traditional surgery for selected patients. Despite a lack of strong evidence, such as large prospective randomized studies, laparoscopic donor nephrectomy is likely to become the gold standard for donor nephrectomy in the near future.

  10. Estimating Surgical Procedure Times Using Anesthesia Billing Data and Operating Room Records.

    PubMed

    Burgette, Lane F; Mulcahy, Andrew W; Mehrotra, Ateev; Ruder, Teague; Wynn, Barbara O

    2017-02-01

    The median time required to perform a surgical procedure is important in determining payment under Medicare's physician fee schedule. Prior studies have demonstrated that the current methodology of using physician surveys to determine surgical times results in overstated times. To measure surgical times more accurately, we developed and validated a methodology using available data from anesthesia billing data and operating room (OR) records. We estimated surgical times using Medicare 2011 anesthesia claims and New York Statewide Planning and Research Cooperative System 2011 OR times. Estimated times were validated using data from the National Surgical Quality Improvement Program. We compared our time estimates to those used by Medicare in the fee schedule. We estimate surgical times via piecewise linear median regression models. Using 3.0 million observations of anesthesia and OR times, we estimated surgical time for 921 procedures. Correlation between these time estimates and directly measured surgical time from the validation database was 0.98. Our estimates of surgical time were shorter than the Medicare fee schedule estimates for 78 percent of procedures. Anesthesia and OR times can be used to measure surgical time and thereby improve the payment for surgical procedures in the Medicare fee schedule. © Health Research and Educational Trust.

  11. POSSIBLE CHROMOSPHERIC ACTIVITY CYCLES IN AD LEO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buccino, Andrea P.; Petrucci, Romina; Mauas, Pablo J. D.

    2014-01-20

    AD Leo (GJ 388) is an active dM3 flare star that has been extensively observed both in the quiescent and flaring states. Since this active star is near the fully convective boundary, studying its long-term chromospheric activity in detail could be an appreciable contribution to dynamo theory. Here, using the Lomb-Scargle periodogram, we analyze the Ca II K line-core fluxes derived from CASLEO spectra obtained between 2001 and 2013 and the V magnitude from the ASAS database between 2004 and 2010. From both of these totally independent time series, we obtain a possible activity cycle with a period of approximately seven yearsmore » and a less significant shorter cycle of approximately two years. A tentative interpretation is that a dynamo operating near the surface could be generating the longer cycle, while a second dynamo operating in the deep convection zone could be responsible for the shorter one. Based on the long duration of our observing program at CASLEO and the fact that we observe different spectral features simultaneously, we also analyze the relation between simultaneous measurements of the Na I index (R{sub D}{sup ′}), Hα, and Ca II K fluxes at different activity levels of AD Leo, including flares.« less

  12. Analysis of Multi-Flight Common Routes for Traffic Flow Management

    NASA Technical Reports Server (NTRS)

    Sheth, Kapil; Clymer, Alexis; Morando, Alex; Shih, Fu-Tai

    2016-01-01

    When severe convective weather requires rerouting aircraft, FAA traffic managers employ severe weather avoidance plans (e.g., Playbook routes, Coded Departure Routes, etc.) These routes provide pilots with safe paths around weather-affected regions, and provide controllers with predictable, and often well-established flight plans. However, they often introduce large deviations to the nominal flight plans, which may not be necessary as weather conditions change. If and when the imposed traffic management initiatives (TMIs) become stale, updated shorter path flight trajectories may be found en route, providing significant time-savings to the affected flights. Multiple Flight Common Routes (MFCR) is a concept that allows multiple flights that are within a specified proximity or region, to receive updated shorter flight plans in an operationally efficient manner. MFCR is believed to provide benefits to the National Airspace System (NAS) by allowing traffic managers to update several flight plans of en route aircraft simultaneously, reducing operational workload within the TMUs of all affected ARTCCs. This paper will explore some aspects of the MFCR concept by analyzing multiple flights that have been selected for rerouting by the NAS Constraint Evaluation and Notification Tool (NASCENT). Various methods of grouping aircraft with common or similar routes will be presented, along with a comparison of the efficacy of these methods.

  13. Effect of nerve monitoring on complications of thyroid surgery

    PubMed Central

    Demiryas, Suleyman; Donmez, Turgut; Cekic, Erdinc

    2018-01-01

    OBJECTIVE: The most frequent and critical complications of thyroid surgery are recurrent laryngeal nerve palsy and hypocalcemia. In first years of the 21st century, intraoperative neuromonitoring (IONM) was introduced as a new technique to avoid the recurrent laryngeal nerve (RLN) injury. However, the role and the benefits of IONM are still controversial. In this study, we aimed to compare the postoperative complication rates during thyroid surgery with IONM usage (Group 1) and conventional direct visual technique without IONM usage (Group 2). METHODS: We conducted retrospective review of all patients undergoing thyroid surgery in Lütfiye Nuri Burat State Hospital General Surgery Department between 2014 and 2016 years. Patients have been classified in to two groups: Group 1 and 2. RESULTS: Overall, 191 patients were included in the study; Group 1 comprised 79 patients and Group 2 comprised 112 patients. Unilateral RLN paralysis was observed in 7 patients in Group 1 (8.9%) and 15 patients in Group 2 (13.4%) without any significant difference between the groups (p=0.368). Hypocalcemia was encountered in 5 patients (6.3%) in Group 1 and 18 patients (16.1%) in Group 2; this difference was statistically significant (p=0.045). Other complications (such as hematoma and suture reaction) were not significantly different. Operation time was found to be significantly shorter in Group 1 (Mean time, 93.08 min) than in Group 2 (116.54 min) (p=0.03). CONCLUSION: Proven effect of IONM on RLN paralysis is still controversial. However, easy identification of RLN, which gives more confidence to surgeon, and shorter operation time may be factors to lower hypocalcemia rates. PMID:29607426

  14. Robotic bariatric surgery: a systematic review.

    PubMed

    Fourman, Matthew M; Saber, Alan A

    2012-01-01

    Obesity is a nationwide epidemic, and the only evidence-based, durable treatment of this disease is bariatric surgery. This field has evolved drastically during the past decade. One of the latest advances has been the increased use of robotics within this field. The goal of our study was to perform a systematic review of the recent data to determine the safety and efficacy of robotic bariatric surgery. The setting was the University Hospitals Case Medical Center (Cleveland, OH). A PubMed search was performed for robotic bariatric surgery from 2005 to 2011. The inclusion criteria were English language, original research, human, and bariatric surgical procedures. Perioperative data were then collected from each study and recorded. A total of 18 studies were included in our review. The results of our systematic review showed that bariatric surgery, when performed with the use of robotics, had similar or lower complication rates compared with traditional laparoscopy. Two studies showed shorter operative times using the robot for Roux-en-Y gastric bypass, but 4 studies showed longer operative times in the robotic arm. In addition, the learning curve appears to be shorter when robotic gastric bypass is compared with the traditional laparoscopic approach. Most investigators agreed that robotic laparoscopic surgery provides superior imaging and freedom of movement compared with traditional laparoscopy. The application of robotics appears to be a safe option within the realm of bariatric surgery. Prospective randomized trials comparing robotic and laparoscopic outcomes are needed to further define the role of robotics within the field of bariatric surgery. Longer follow-up times would also help elucidate any long-term outcomes differences with the use of robotics versus traditional laparoscopy. Copyright © 2012 American Society for Metabolic and Bariatric Surgery. All rights reserved.

  15. Comparison between the short-term results of onlay and sublay mesh placement in the management of uncomplicated para-umbilical hernia: a prospective randomized study.

    PubMed

    Bessa, S S; El-Gendi, A M; Ghazal, A H A; Al-Fayoumi, T A

    2015-02-01

    The aim of this study was to compare between the short-term results of onlay and sublay mesh placement in the prosthetic repair of uncomplicated para-umbilical hernia (PUH). Eighty patients with a defect size ranging from 4 to 10 cm were prospectively randomized to either the onlay group (40 patients) or the sublay group (40 patients). The operative time, postoperative complications and short-term recurrence were reported. There were no statistically significant differences between both study groups as regards the patients' demographics, associated co-morbidities and mean defect size. The median operative time was significantly shorter in the onlay group compared to that in the sublay group (52 vs. 91 min respectively, p < 0.001). No statistically significant difference was found in the daily median pain score throughout the first postoperative week. The time required to remove the suction drain was significantly shorter in the sublay group compared to that in the onlay group (3 vs. 7 days respectively, p < 0.001).Complications were encountered in 4 patients (10%) in the onlay group compared to 3 patients (7.5%) in the sublay group (p = 1.000). Superficial wound infection was encountered in 1 patient (2.5%) in the sublay group, Seroma was encountered in 2 patients (5%) in the onlay group, Deep vein thrombosis was encountered in 1 patient (2.5%) in the onlay group, Chest infection was encountered in 2 patients (5%) in the sublay group compared to 1 patient (2.5%) in the onlay group. Throughout the 22 months median follow-up duration (range 6-42 months), 2 recurrences (5%) were encountered in either study group. Both techniques are safe, efficient and are associated with comparable complication and recurrence rates.

  16. Reversal of the Hartmann's procedure: A comparative study of laparoscopic versus open surgery.

    PubMed

    Melkonian, Ernesto; Heine, Claudio; Contreras, David; Rodriguez, Marcelo; Opazo, Patricio; Silva, Andres; Robles, Ignacio; Rebolledo, Rolando

    2017-01-01

    The Hartmann's operation, although less frequently performed today, is still used when initial colonic anastomosis is too risky in the short term. However, the subsequent procedure to restore gastrointestinal continuity is associated with significant morbidity and mortality. The review of an institutional review board (IRB)-approved prospectively maintained database provided data on the Hartmann's reversal procedure performed by either laparoscopic or open technique at our institution. The data collected included: demographic data, operative approach, conversion for laparoscopic cases and perioperative morbidity and mortality. Over a 14-year period from January 1997 to August 2011, 74 Hartmann's reversal procedures were performed (laparoscopic surgery-49, open surgery-25). The average age was 55 years for the laparoscopic and 57 years for the open surgery group, respectively. Male patients represent 61% of both groups. There was no significant difference in operative time between the two groups (149 min vs 151 min; P = 0.95), and there was a tendency to lower morbidity (3/49-7.3% vs 4/25-16%; P = 0.24) in the laparoscopic surgery group. In the laparoscopic group, eight patients (16.3%) were converted to open surgery, mostly due to severe adhesions. The length of hospital stay was significantly shorter for the laparoscopic group (5 days vs 7 days; P = 0.44). The Hartmann's reversal procedure can be safely performed in the majority of the cases using a laparoscopic approach with a low morbidity rate and achieving a shorter hospital stay.

  17. Use of Variable Pressure Suits, Intermittent Recompression and Nitrox Breathing Mixtures during Lunar Extravehicular Activities

    NASA Technical Reports Server (NTRS)

    Gernhardt, Michael L.; Abercromby, Andrew F.

    2009-01-01

    This slide presentation reviews the use of variable pressure suits, intermittent recompression and Nitrox breathing mixtures to allow for multiple short extravehicular activities (EVAs) at different locations in a day. This new operational concept of multiple short EVAs requires short purge times and shorter prebreathes to assure rapid egress with a minimal loss of the vehicular air. Preliminary analysis has begun to evaluate the potential benefits of the intermittent recompression, and Nitrox breathing mixtures when used with variable pressure suits to enable reduce purges and prebreathe durations.

  18. Expert database system for quality control

    NASA Astrophysics Data System (ADS)

    Wang, Anne J.; Li, Zhi-Cheng

    1993-09-01

    There are more competitors today. Markets are not homogeneous they are fragmented into increasingly focused niches requiring greater flexibility in the product mix shorter manufacturing production runs and above allhigher quality. In this paper the author identified a real-time expert system as a way to improve plantwide quality management. The quality control expert database system (QCEDS) by integrating knowledge of experts in operations quality management and computer systems use all information relevant to quality managementfacts as well as rulesto determine if a product meets quality standards. Keywords: expert system quality control data base

  19. Study of experiments on condensation of nitrogen by homogeneous nucleation at states modelling those on the national transonic facility

    NASA Technical Reports Server (NTRS)

    Wegener, P. P.

    1980-01-01

    A cryogenic wind tunnel is based on the twofold idea of lowering drive power and increasing Reynolds number by operating with nitrogen near its boiling point. There are two possible types of condensation problems involved in this mode of wind tunnel operation. They concern the expansion from the nozzle supply to the test section at relatively low cooling rates, and secondly the expansion around models in the test section. This secondary expansion involves higher cooling rates and shorter time scales. In addition to these two condensation problems it is not certain what purity of nitrogen can be achieved in a large facility. Therefore, one cannot rule out condensation processes other than those of homogeneous nucleation.

  20. Minimally invasive mitral valve surgery is associated with equivalent cost and shorter hospital stay when compared with traditional sternotomy.

    PubMed

    Atluri, Pavan; Stetson, Robert L; Hung, George; Gaffey, Ann C; Szeto, Wilson Y; Acker, Michael A; Hargrove, W Clark

    2016-02-01

    Mitral valve surgery is increasingly performed through minimally invasive approaches. There are limited data regarding the cost of minimally invasive mitral valve surgery. Moreover, there are no data on the specific costs associated with mitral valve surgery. We undertook this study to compare the costs (total and subcomponent) of minimally invasive mitral valve surgery relative to traditional sternotomy. All isolated mitral valve repairs performed in our health system from March 2012 through September 2013 were analyzed. To ensure like sets of patients, only those patients who underwent isolated mitral valve repairs with preoperative Society of Thoracic Surgeons scores of less than 4 were included in this study. A total of 159 patients were identified (sternotomy, 68; mini, 91). Total incurred direct cost was obtained from hospital financial records. Analysis demonstrated no difference in total cost (operative and postoperative) of mitral valve repair between mini and sternotomy ($25,515 ± $7598 vs $26,049 ± $11,737; P = .74). Operative costs were higher for the mini cohort, whereas postoperative costs were significantly lower. Postoperative intensive care unit and total hospital stays were both significantly shorter for the mini cohort. There were no differences in postoperative complications or survival between groups. Minimally invasive mitral valve surgery can be performed with overall equivalent cost and shorter hospital stay relative to traditional sternotomy. There is greater operative cost associated with minimally invasive mitral valve surgery that is offset by shorter intensive care unit and hospital stays. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  1. Anterolateral minithoracotomy versus median sternotomy for the treatment of congenital heart defects: a meta-analysis and systematic review.

    PubMed

    Ding, Chao; Wang, Chunmao; Dong, Aiqiang; Kong, Minjian; Jiang, Daming; Tao, Kaiyu; Shen, Zhonghua

    2012-05-04

    Anterolateral Minithoracotomy (ALMT) for the radical correction of Congenital Heart Defects is an alternative to Median Sternotomy (MS) due to reduce operative trauma accelerating recovery and yield a better cosmetic outcome after surgery. Our purpose is to conduct whether ALMT would bring more short-term benefits to patients than conventional Median Sternotomy by using a meta-analysis of case-control study in the published English Journal. 6 case control studies published in English from 1997 to 2011 were identified and synthesized to compare the short-term postoperative outcomes between ALMT and MS. These outcomes were cardiopulmonary bypass time, aortic cross-clamp time, intubation time, intensive care unit stay time, and postoperative hospital stay time. ALMT had significantly longer cardiopulmonary bypass times (8.00 min more, 95% CI 0.36 to 15.64 min, p = 0.04). Some evidence proved that aortic cross-clamp time of ALMT was longer, yet not significantly (2.38 min more, 95% CI -0.15 to 4.91 min, p = 0.06). In addition, ALMT had significantly shorter intubation time (1.66 hrs less, 95% CI -3.05 to -0.27 hrs, p = 0.02). Postoperative hospital stay time was significantly shorter with ALMT (1.52 days less, 95% CI -2.71 to -0.33 days, p = 0.01). Some evidence suggested a reduction in ICU stay time in the ALMT group. However, this did not prove to be statistically significant (0.88 days less, 95% CI -0.81 to 0.04 days, p = 0.08). ALMT can bring more benefits to patients with Congenital Heart Defects by reducing intubation time and postoperative hospital stay time, though ALMT has longer CPB time and aortic cross-clamp time.

  2. Severe retroperitoneal and intra-abdominal bleeding after stapling procedure for prolapsed haemorrhoids (PPH); diagnosis, treatment and 6-year follow-up of the case.

    PubMed

    Safadi, Wajdi; Altshuler, Alexander; Kiv, Sakal; Waksman, Igor

    2014-10-30

    Procedure for prolapsed haemorrhoids (PPH) is a popular treatment of haemorrhoids. PPH has the advantages of a shorter operation time, minor degree of postoperative pain, shorter hospital stay and quicker recovery but may be followed by several postoperative complications. Rectal bleeding, acute pain, chronic pain, rectovaginal fistula, complete rectal obliteration, rectal stenosis, rectal pocket, tenesmus, faecal urgency, faecal incontinence, rectal perforation, pelvic sepsis and rectal haematoma have all been reported as postoperative complications of PPH. Additionally, one rare complication of the procedure is intra-abdominal bleeding. There are a few case reports describing intra-abdominal bleeding after the procedure. We report a case of a 26-year-old man who developed severe intra-abdominal and retroperitoneal haemorrhage after PPH. The diagnosis was made on the second postoperative day by CT of the abdomen and pelvis. The patient was treated conservatively and had an uneventful recovery. 2014 BMJ Publishing Group Ltd.

  3. The Brief Death Implicit Association Test: Scoring recommendations, reliability, validity, and comparisons with the Death Implicit Association Test.

    PubMed

    Millner, Alexander J; Coppersmith, Daniel D L; Teachman, Bethany A; Nock, Matthew K

    2018-05-21

    Assessing suicidal thoughts and behaviors is difficult because at-risk individuals often fail to provide honest or accurate accounts of their suicidal thoughts or intentions. Research has shown that the Death Implicit Association Test (D-IAT), a behavioral test that measures implicit (i.e., outside of conscious control) associations between oneself and death concepts, can differentiate among people with different suicidal histories, such as those with different severity or recency of suicidal behaviors. We report here on the development and evaluation of a shorter and simpler version of the D-IAT called the Death Brief Implicit Association Test (D-BIAT). We recruited large (ns > 1,500) samples of participants to complete the original D-IAT and shorter D-BIAT via a public web-based platform and evaluated different scoring approaches, assessed the reliability and validity of the D-BIAT and compared it with the D-IAT. We found that the D-BIAT was reliable, provided significant group differences with effect sizes on par with the D-IAT, as well as similarly sized classification metrics (i.e., receiver operator characteristics). Although the D-IAT was nonsignificantly better on most outcomes, the D-BIAT is 1-1[1/2] minutes shorter and provided larger effect sizes for distinguishing between past year and lifetime attempters. Thus, there is a trade-off between administration time and improved outcomes associated with increased data. The D-BIAT should be considered for use where time or participant burden needs to be minimized, such as in clinical settings. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  4. Retroperitoneal Varix ligation with sclerotherapy: a prospective randomized comparative study

    PubMed Central

    Abdelsalam, Yaser M.; Saeed, Waleed M.; Elganainy, Ehab O.; Ahmed, Abdelfatah I.

    2017-01-01

    Introduction The aim of this article is to compare the results of high varix ligation with and without sclerotherapy. Material and methods Between November 2014 and December 2015, sixty patients with varicocele were included in this study. Patients were divided into two equal groups; group I (underwent high varix ligation), and group II (underwent high varix ligation with a retrograde injection of 2 mL of 5% ethanolamine oleate in the lower end of the bisected gonadal vein). The operative time, intra- and postoperative complications, postoperative pain, improvement of semen parameters, incidence of recurrence and achieving of unassisted pregnancy were recorded for both groups. Results The age range was 19–34 years in group I and 21–37 years in group II. The operative time was shorter in group I (34.6 ±7.81 min) than group II (43.3 ±8.5 min) (P <0.001), which was statistically significant. Improvement of semen parameters and the occurrence of spontaneous pregnancy were insignificant between both groups. No intraoperative complications occurred. The postoperative complications were statistically insignificant in both groups. Conclusions Combined varix ligation with retrograde sclerotherapy does not offer significant advantages over high varix ligation alone with a longer operative time and prolonged post-operative pain. PMID:29104794

  5. Outcomes and cost analysis of laparoscopic versus open appendectomy for treatment of acute appendicitis: 4-years experience in a district hospital

    PubMed Central

    2014-01-01

    Background Laparoscopic appendectomy is not yet unanimously considered the “gold standard” in the treatment of acute appendicitis because of its higher operative time, intra-abdominal abscess risk, and costs compared to open appendectomy. This study aimed to compare outcomes and cost of laparoscopic and open appendectomy in a district hospital. Methods A retrospective analysis of 230 patients who underwent appendectomy at the Division of General Surgery of the Civil Hospital of Ragusa, Italy, from May 2008 to May 2012 was performed. The variables analyzed included patients data (age, gender, previous abdominal surgery, preoperative WBC count, duration of symptoms, ASA risk score), rate of uncomplicated or complicated appendicitis, operative time, postoperative complications, length of hospital stay, and total costs. The patients were divided in two groups according to the surgical approach and compared for each variable. The results were analyzed using the t Student test for quantitative variables, and the Chi-square test with Yates correction and Fisher exact test for categorical. Results Laparoscopic appendectomy was performed in 139 patients, open appendectomy in 91. Two cases (1.4%) were converted to open procedure and included in the laparoscopic group data. Patient data and rate of complicated appendicitis were similar in the two study groups. There was no statistical difference (p = 0.476) in the mean operative time between the laparoscopic (52.2 min; range, 20–155) and open appendectomy (49.3 min; range, 20–110) groups. The overall incidence of minor and major complications was significantly lower (p = 0.006) after laparoscopic appendectomy (2.9%, 4 cases) than after open appendectomy (13.2%, 12 cases); rate of intra-abdominal abscess were similar. The length of hospital stay was significantly shorter (p = 0.001) in laparoscopic group (2.75 days; range, 1–8) than in open group (3.87 days; range, 1–19). The mean total cost was 2282 Euro in laparoscopic group and 2337 Euro in open group, with a no significant difference of 55 Euro (p = 0.812). Conclusion Laparoscopic appendectomy is associated with fewer complications, shorter hospital stay, and similar operative time, intra-abdominal abscess rate, and total costs, compared with open appendectomy. Therefore, laparoscopic appendectomy can be recommended as preferred approach in acute appendicitis. PMID:24646120

  6. Modified hysteroscopic myomectomy of large submucous fibroids.

    PubMed

    Darwish, Atef

    2003-01-01

    To compare the efficacy, feasibility, operative time and possible complications of a modified technique of hysteroscopic removal of large submucus myomata versus traditional morcellation technique, and to assess the efficacy of preoperative sonohysterography (SHG). A prospective comparative study. Gynecologic Endoscopy Unit, Assiut University Hospital, Assiut, Egypt. One hundred forty-two women of childbearing age with a clinical and transvaginal sonographic diagnosis of large solitary submucous myomata (>3 cm in diameter) with or without an intramural element. The patients were divided into two groups. In group A (65 patients), a modified resectoscopic technique was used where the base of the myoma was excised followed by ring forceps extraction after misoprostol priming. In group B (77 patients), the myoma was cut using traditional resectoscopic morcellation. For each patient, operating time, intra- and postoperative complications and feasibility of the procedure were recorded. The accuracy of preoperative SHG in localizing submucous myoma and detecting intramural extension was assessed by diagnostic hysteroscopy. Transvaginal SHG showed good agreement with hysteroscopy in localizing submucous myomata and detecting intramural extension (k = 0.83). The operating time was significantly shorter in group A (15.6 +/- 3.02 min) than in group B (28.9 +/- 4.3 min). The procedure was completed in 60 (92%) and 51 patients (66%), whereas a second session was required in 2 (3%) and 20 patients (25.9%) in both groups respectively. Glycine volume was highly significantly less in group A (2.3 +/- 0.86 vs. 6.3+/- 1.7 liters, p = 0.001). Intraoperative complications were encountered in 9 (13.8%) and 22 patients (28.5%) in both groups respectively (p = 0.03). Cervical laceration was diagnosed in 3 cases (4.6%) in group A. Postoperative visual disturbances were diagnosed in 4 cases (5%) in group B. Hysteroscopic resection of large submucous myomata with minimal intramural encroachment is feasible using a modified technique. It shows a minimal complication rate and fluid deficit and a shorter operative time than the standard morcellation technique. If the excised myoma is extracted as one mass, this carries a minimal risk of cervical lacerations and possible cervical incompetence in a subsequent pregnancy. Transvaginal SHG is a reliable diagnostic aid to assess submucous myomata. Copyright 2003 S. Karger AG, Basel

  7. Usefulness of video-laryngoscopy with the Airway Scope for intubation performance and learning: an experimental manikin controlled study.

    PubMed

    Declercq, Pierre-Louis; Bubenheim, Michael; Gelinotte, Stéphanie; Guernon, Kévin; Michot, Jean-Baptiste; Royon, Vincent; Carpentier, Dorothée; Béduneau, Gaëtan; Tamion, Fabienne; Girault, Christophe

    2016-12-01

    Different video-laryngoscopes (VDLs) for endotracheal intubation (ETI) have recently been developed. We compared the performance of the VDL Airway Scope (AWS) with the direct laryngoscopy by Macintosh (DLM) for ETI success, time and learning. We performed an experimental manikin controlled study. Twenty experienced (experts) and 40 inexperienced operators (novices) for DLM-ETI were enrolled. None of them had experience with the use of AWS-VDL. Novices were assigned to start learning with DLM or AWS, and two sub-groups of 20 novices were formed. Experts group constituted the control group. Each participant performed 10 ETI attempts with each device on the same standard manikin. The primary endpoint was the ETI success probability. Secondary endpoints were ETI time, technical validity and qualitative evaluation for each technique. We also assessed the learning order and the successive attempts effects for these parameters. Overall, 1200 ETI attempts were performed. ETI success probability was higher with the AWS than with the DLM for all operators (98 vs. 81 %; p < 0.0001) and for experts compared to novices using devices in the same order (97 vs. 83 %; p = 0.0002). Overall ETI time was shorter with the AWS than with the DLM (13 vs. 20 s; p < 0.0001) and for experts compared to novices using devices in the same order (11 vs. 21 s; p < 0.0001). Among novices, those starting learning with AWS had higher ETI success probability (89 vs. 83 %; p = 0.03) and shorter ETI time (18 vs. 21 s; p = 0.02). Technical validity was found better with the AWS than DLM for all operators. Novices expressed global satisfaction and device preference for the AWS, whereas experts were indifferent. AWS-VDL permits faster, easier and more reliable ETI compared to the DLM whatever the previous airway ETI experience and could be a useful device for DLM-ETI learning.

  8. Development of a New Time-Resolved Laser-Induced Fluorescence Technique

    NASA Astrophysics Data System (ADS)

    Durot, Christopher; Gallimore, Alec

    2012-10-01

    We are developing a time-resolved laser-induced fluorescence (LIF) technique to interrogate the ion velocity distribution function (VDF) of EP thruster plumes down to the microsecond time scale. Better measurements of dynamic plasma processes will lead to improvements in simulation and prediction of thruster operation and erosion. We present the development of the new technique and results of initial tests. Signal-to-noise ratio (SNR) is often a challenge for LIF studies, and it is only more challenging for time-resolved measurements since a lock-in amplifier cannot be used with a long time constant. The new system uses laser modulation on the order of MHz, which enables the use of electronic filtering and phase-sensitive detection to improve SNR while preserving time-resolved information. Statistical averaging over many cycles to further improve SNR is done in the frequency domain. This technique can have significant advantages, including (1) larger spatial maps enabled by shorter data acquisition time and (2) the ability to average data without creating a phase reference by modifying the thruster operating condition with a periodic cutoff in discharge current, which can modify the ion velocity distribution.

  9. Reusable single-port access device shortens operative time and reduces operative costs.

    PubMed

    Shussman, Noam; Kedar, Asaf; Elazary, Ram; Abu Gazala, Mahmoud; Rivkind, Avraham I; Mintz, Yoav

    2014-06-01

    In recent years, single-port laparoscopy (SPL) has become an attractive approach for performing surgical procedures. The pitfalls of this approach are technical and financial. Financial concerns are due to the increased cost of dedicated devices and prolonged operating room time. Our aim was to calculate the cost of SPL using a reusable port and instruments in order to evaluate the cost difference between this approach to SPL using the available disposable ports and standard laparoscopy. We performed 22 laparoscopic procedures via the SPL approach using a reusable single-port access system and reusable laparoscopic instruments. These included 17 cholecystectomies and five other procedures. Operative time, postoperative length of stay (LOS) and complications were prospectively recorded and were compared with similar data from our SPL database. Student's t test was used for statistical analysis. SPL was successfully performed in all cases. Mean operative time for cholecystectomy was 72 min (range 40-116). Postoperative LOS was not changed from our standard protocols and was 1.1 days for cholecystectomy. The postoperative course was within normal limits for all patients and perioperative morbidity was recorded. Both operative time and length of hospital stay were shorter for the 17 patients who underwent cholecystectomy using a reusable port than for the matched previous 17 SPL cholecystectomies we performed (p < 0.001). Prices of disposable SPL instruments and multiport access devices as well as extraction bags from different manufacturers were used to calculate the cost difference. Operating with a reusable port ended up with an average cost savings of US$388 compared with using disposable ports, and US$240 compared with standard laparoscopy. Single-port laparoscopic surgery is a technically challenging and expensive surgical approach. Financial concerns among others have been advocated against this approach; however, we demonstrate herein that using a reusable port and instruments reduces operative time and overall operative costs, even beyond the cost of standard laparoscopy.

  10. Two Different Percutaneous Bone-Anchored Hearing Aid Abutment Systems: Comparative Clinical Study.

    PubMed

    Polat, Beldan; İşeri, Mete; Orhan, Kadir Serkan; Yılmazer, Ayça Başkadem; Enver, Necati; Ceylan, Didem; Kara, Ahmet; Güldiken, Yahya; Çomoğlu, Şenol

    2016-04-01

    To compare two different percutaneous bone-anchored hearing aid (BAHA) abutment systems regarding operation time, scar healing, quality of life, implant stability, audiologic results, and complications. The study involves a prospective multi-center clinical evaluation. Thirty-two consecutive patients who had undergone BAHA surgery from January 2011 to January 2013 in two tertiary centers were included in the study. The Glasgow Inventory Benefit Score was used to assess the patients at least 6 months after surgery. The operation time and complications were recorded. Implant stability quotient (ISQ) values were recorded using resonance frequency analysis. Holger's classification was used to evaluate skin reactions. The mean length of the operation was 39.2±4 min for standard abutment and 18.3±5.7 min for hydroxyapatite-coated abutment. ISQ scores were significantly better for standard abutment in all tests. The mean total Glasgow Inventory Benefit Score was 39.3±19 for the standard abutment and 46.3±24.5 for the hydroxyapatite-coated abutment groups, but there was no statistical significance between the two groups. There was no difference in audiological improvement between the two groups after surgery. Hydroxyapatite-coated abutment provided a shorter operation time that was significantly different from standard abutment. There were no significant differences between standard abutment and hydroxyapatite-coated abutment regarding audiologic improvement, quality of life, loading time, and complications.

  11. Application study of evolutionary operation methods in optimization of process parameters for mosquito coils industry

    NASA Astrophysics Data System (ADS)

    Ginting, E.; Tambunanand, M. M.; Syahputri, K.

    2018-02-01

    Evolutionary Operation Methods (EVOP) is a method that is designed used in the process of running or operating routinely in the company to enables high productivity. Quality is one of the critical factors for a company to win the competition. Because of these conditions, the research for products quality has been done by gathering the production data of the company and make a direct observation to the factory floor especially the drying department to identify the problem which is the high water content in the mosquito incense coil. PT.X which is producing mosquito coils attempted to reduce product defects caused by the inaccuracy of operating conditions. One of the parameters of good quality insect repellent that is water content, that if the moisture content is too high then the product easy to mold and broken, and vice versa if it is too low the products are easily broken and burn shorter hours. Three factors that affect the value of the optimal water content, the stirring time, drying temperature and drying time. To obtain the required conditions Evolutionary Operation (EVOP) methods is used. Evolutionary Operation (EVOP) is used as an efficient technique for optimization of two or three variable experimental parameters using two-level factorial designs with center point. Optimal operating conditions in the experiment are stirring time performed for 20 minutes, drying temperature at 65°C, and drying time for 130 minutes. The results of the analysis based on the method of Evolutionary Operation (EVOP) value is the optimum water content of 6.90%, which indicates the value has approached the optimal in a production plant that is 7%.

  12. Preoperative sclerotherapy of facial venous malformations: impact on surgical parameters and long-term follow-up.

    PubMed

    James, Charles A; Braswell, Leah E; Wright, Lonnie B; Roberson, Paula K; Moore, Mary B; Waner, Milton; Buckmiller, Lisa M

    2011-07-01

    To analyze the operative benefit of preoperative sclerotherapy of facial venous malformations and assess long-term patient outcome. Preoperative sclerotherapy was performed in 24 consecutive patients referred before resection of facial venous malformation. Pretreatment imaging was reviewed for malformation dimensions (length, width, and height), and volumes were estimated. Sclerotherapy was performed with 3% sodium tetradecyl in the first 15 patients and 98% dehydrated alcohol in the remaining 9 patients. Operative blood loss, operative time, transfusion requirement, and hospital stay were recorded. Operative time per lesion volume and operative blood loss per lesion volume were calculated. Results were compared with 15 historical control patients who underwent resection of facial venous malformations without preoperative sclerotherapy. Long-term follow-up of study and control patients was performed. Compared with controls, patients undergoing preoperative venous sclerotherapy were significantly older (P = .0206) and had larger lesions in all three dimensions (height, P = .0002; length, P = .0010; width, P = .0004). Patients receiving sclerotherapy had shorter operative time per lesion volume (P < .0001) and reduced blood loss per lesion volume (P < .0001). Neither hospital stay nor the need for blood transfusion differed from the control patients (P = .2449 and P = .6857). Mild periprocedural complications were encountered in 12.5% of cases, and nerve paresis occurred in 8.3% of cases. Long-term follow-up revealed retreatment was required in 2 of 24 patients (8.3%). Preoperative sclerotherapy of venous malformations was associated with less operative time per lesion volume and less operative blood loss per lesion volume. Long-term follow-up revealed a low need for retreatment. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  13. Unipedicular versus bipedicular percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a prospective randomized study.

    PubMed

    Zhang, Liang; Liu, Zhongjun; Wang, Jingcheng; Feng, Xinmin; Yang, Jiandong; Tao, Yuping; Zhang, Shengfei

    2015-06-14

    Percutaneous vertebroplasty (PVP) typically involves conventional lower-viscosity cement injection via bipedicular approach. Limited evidence is available comparing the clinical outcomes and complications in treating osteoporotic vertebral compression fractures (OVCFs) with PVP using high-viscosity cement through unipedicular or bipedicular approach. Fifty patients with OVCFs were randomly allocated into two groups adopting unipedicular or bipedicular PVP. The efficacy of unipedicular and bipedicular PVP was assessed by comparing operation time, X-ray exposure time, incidence of complications, vertebral height restoration, and improvement of the visual analogue scale (VAS), Oswestry disability index (ODI) and Short Form-36 (SF-36) General Health Survey scores. The mean operative and exposure time to X-rays in the unipedicular PVP group was less than that of the bipedicular group (p < 0.05). No statistically significant differences were observed in the VAS score, ODI score, SF-36 score, cement leakage rate or vertebral height restoration between the two groups (p > 0.05). Unipedicular and bipedicular PVP are safe and effective treatments for OVCF. Compared with bipedicular PVP, unipedicular PVP entails a shorter surgical time and lower X-ray irradiation.

  14. Treatment of Intercondylar Humeral Fractures With 3D-Printed Osteosynthesis Plates

    PubMed Central

    Shuang, Feng; Hu, Wei; Shao, Yinchu; Li, Hao; Zou, Hongxing

    2016-01-01

    Abstract The aim of the study was to evaluate the efficacy custom 3D-printed osteosynthesis plates in the treatment of intercondylar humeral fractures. Thirteen patients with distal intercondylar humeral fractures were randomized to undergo surgery using either conventional plates (n = 7) or 3D-printed plates (n = 6) at our institution from March to October 2014. Both groups were compared in terms of operative time and elbow function at 6 month follow-up. All patients were followed-up for a mean of 10.6 months (range: 6–13 months). The 3D-printing group had a significantly shorter mean operative time (70.6 ± 12.1 min) than the conventional plates group (92.3 ± 17.4 min). At the last follow-up period, there was no significant difference between groups in the rate of patients with good or excellent elbow function, although the 3D-printing group saw a slightly higher rate of good or excellent evaluations (83.1%) compared to the conventional group (71.4%). Custom 3D printed osteosynthesis plates are safe and effective for the treatment of intercondylar humeral fractures and significantly reduce operative time. PMID:26817880

  15. Harmonic focus versus electrocautery in axillary lymph node dissection for breast cancer: a randomized clinical study.

    PubMed

    He, Qingqing; Zhuang, Dayong; Zheng, Luming; Fan, Ziyi; Zhou, Peng; Zhu, Jian; Lv, Zhen; Chai, Jixin; Cao, Lei

    2012-12-01

    Electrocautery has been proven to be associated with prolonged serous drainage that might result in several complications in patients requiring axillary lymph node dissection for breast cancer. We proposed that the Harmonic Focus might outperform electrocautery in axillary lymph node dissection, resulting in shorter operative times and reduced postoperative complications. One hundred twenty-eight women with confirmed T1-3 N1-2 breast cancer were randomly assigned to undergo mastectomy or breast-conserving surgery with axillary dissection by using Harmonic Focus or electrocautery. Sixty-four has surgery with Harmonic Focus (group A) and 64 with electrocautery (group B) by the same surgical team. Operative time, blood loss, total drainage volume and days, incidence of seroma, hematoma, pain score, and flap necrosis were recorded. Using Harmonic Focus significantly diminished operative time, blood loss, total drainage volume, days of stay, and visual analogue scale as compared with traditional electrocautery. There was no statistical difference between the 2 groups regarding seroma, hematoma, and flap necrosis. Axillary lymph node dissection using Harmonic Focus is feasible, safe, and a more comfortable design for the surgeon. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. The role of three-dimensional high-definition laparoscopic surgery for gynaecology.

    PubMed

    Usta, Taner A; Gundogdu, Elif C

    2015-08-01

    This article reviews the potential benefits and disadvantages of new three-dimensional (3D) high-definition laparoscopic surgery for gynaecology. With the new-generation 3D high-definition laparoscopic vision systems (LVSs), operation time and learning period are reduced and procedural error margin is decreased. New-generation 3D high-definition LVSs enable to reduce operation time both for novice and experienced surgeons. Headache, eye fatigue or nausea reported with first-generation systems are not different than two-dimensional (2D) LVSs. The system's being more expensive, having the obligation to wear glasses, big and heavy camera probe in some of the devices are accounted for negative aspects of the system that need to be improved. Depth loss in tissues in 2D LVSs and associated adverse events can be eliminated with 3D high-definition LVSs. By virtue of faster learning curve, shorter operation time, reduced error margin and lack of side-effects reported by surgeons with first-generation systems, 3D LVSs seem to be a strong competition to classical laparoscopic imaging systems. Thanks to technological advancements, using lighter and smaller cameras and monitors without glasses is in the near future.

  17. Waiting times for hospital admissions: the impact of GP fundholding.

    PubMed

    Propper, Carol; Croxson, Bronwyn; Shearer, Arran

    2002-03-01

    Waiting times for hospital care are a significant issue in the UK National Health Service (NHS). The reforms of the health service in 1990 gave a subset of family doctors (GP fundholders) both the ability to choose the hospital where their patients were treated and the means to pay for some services. One of the key factors influencing family doctors' choice of hospital was patient waiting time. However, without cash inducements, hospitals would get no direct reward from giving shorter waiting times to a subset of patients. Using a unique dataset, we investigate whether GP fundholders were able to secure shorter waiting times for their patients, whether they were able to do so in cases where they had no financial rewards to offer hospitals, and whether the impact of fundholding spilled over into shorter waiting times for all patients.

  18. Time-to-reperfusion in STEMI undergoing interhospital transfer using smartphone and WhatsApp messenger.

    PubMed

    Astarcioglu, Mehmet Ali; Sen, Taner; Kilit, Celal; Durmus, Halil Ibrahim; Gozubuyuk, Gokhan; Kalcik, Macit; Karakoyun, Suleyman; Yesin, Mahmut; Zencirkiran Agus, Hicaz; Amasyali, Basri

    2015-10-01

    The objective of this study is to assess the efficacy of WhatsApp application as a communication method among the emergency physician (EP) in a rural hospital without percutaneous coronary intervention (PCI) capability and the interventional cardiologist at a tertiary PCI center. Current guidelines recommend that patients with ST-segment elevation myocardial infarction (STEMI) receive primary PCI within 90 minutes. This door-to-balloon (D2B) time has been difficult to achieve in rural STEMI. We evaluated 108 patients with STEMI in a rural hospital with emergency department but without PCI capability to determine the impact of WhatsApp triage and activation of the cardiac catheterization laboratory on D2B time. The images were obtained from cases of suspected STEMI using the smartphones by the EP and were sent to the interventional cardiologist via the WhatsApp application (group 1, n=53). The control group included concurrently treated patients with STEMI during the same period but not receiving triage (group 2, n=55). The D2B time was significantly shorter in the intervention group (109±31 vs 130±46 minutes, P<.001) with significant reduction in false STEMI rate as well. This study demonstrates that use of WhatsApp triage with activation of the cardiac catheterization laboratory was associated with shorter D2B time and results in a greater proportion of patients achieving guideline recommendations. The method is cheap, quick, and easy to operate. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Comparable operative times with and without surgery resident participation.

    PubMed

    Uecker, John; Luftman, Kevin; Ali, Sadia; Brown, Carlos

    2013-01-01

    Both physicians and patients may perceive that having surgical residents participate in operative procedures may prolong operations and worsen outcomes. We hypothesized that resident participation would prolong operative times and potentially adversely affect postoperative outcomes. To evaluate the effect of general surgery resident participation in surgical procedures on operative times and postoperative patient outcomes. Retrospective study of general surgery procedures performed during two 1-year time periods, 2007 without residents and 2011 with residents. Procedures included laparoscopic appendectomy and cholecystectomy, thyroidectomy, breast procedure, hernia repair, lower extremity amputation, tunneled venous catheter, and percutaneous endoscopic gastrostomy. The primary outcome was operative time and secondary outcomes included length of stay (LOS) and mortality. Academic general surgery residency program. There were 2280 operative procedures performed during the 2 periods: 1150 with resident involvement (RES group) and 1130 without residents (NORES group). The RES and NORES groups were similar for patient age (42 vs 41, p = 0.14) and male gender (46% vs 45%, p = 0.68), and there was no difference in overall operative time (68min vs 66min, p = 0.58). More specifically there was no difference in operative time (minutes) for specific procedures including laparoscopic appendectomy (67 vs 71, p = 0.8), thyroidectomy (125 vs 109, p = 0.16), breast procedure (38 vs 26, p = 0.79), hernia repair (61 vs 60, p = 0.74), lower extremity amputation (65 vs 77, p = 0.16), tunneled venous catheter (49 vs 47, p = 0.75), and percutaneous endoscopic gastrostomy (49 vs 46, p = 0.76). However, laparoscopic cholecystectomy took slightly longer in the RES group (71 vs 66, p = 0.02). LOS was shorter during the year with resident involvement (2.6 days vs 3.7 days, p = 0.0004) and there was no difference in mortality (0.17% vs 0.35%, p = 0.45). There is no difference in operative time for common general surgery procedures with or without resident involvement. In addition, resident involvement is associated with a decrease in LOS. This information should be used to change physician and patient negative perceptions regarding resident involvement while performing surgical procedures. © 2013 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  20. 7 CFR 58.101 - Meaning of words.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... solution for the destruction of most human pathogens and other vegetative microorganisms to a level... the milk product, or the health of consumers. Sanitizing solutions shall comply with 21 CFR 178.1010... (higher heat shorter time pasteurization) 1.0 second. 194 °F (higher heat shorter time pasteurization) 0.5...

  1. 7 CFR 58.101 - Meaning of words.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... solution for the destruction of most human pathogens and other vegetative microorganisms to a level... the milk product, or the health of consumers. Sanitizing solutions shall comply with 21 CFR 178.1010... (higher heat shorter time pasteurization) 1.0 second. 194 °F (higher heat shorter time pasteurization) 0.5...

  2. 7 CFR 58.101 - Meaning of words.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... solution for the destruction of most human pathogens and other vegetative microorganisms to a level... the milk product, or the health of consumers. Sanitizing solutions shall comply with 21 CFR 178.1010... (higher heat shorter time pasteurization) 1.0 second. 194 °F (higher heat shorter time pasteurization) 0.5...

  3. Extracapsular dissection for Warthin tumor in the tail of parotid gland.

    PubMed

    Lee, Dong Hoon; Yoon, Tae Mi; Lee, Joon Kyoo; Lim, Sang Chul

    2017-09-01

    Extracapsular dissection conferred the advantage of reduced operation time and morbidity without any recurrence, and it could be considered as the treatment of choice for Warthin tumors in the tail of the parotid gland. The purpose of this study is to confirm the appropriate surgical procedure for Warthin tumor in the tail of the parotid gland, by comparing the results of extracapsular dissection and superficial parotidectomy. The medical records of 72 patients with Warthin tumor in the tail of the parotid gland who underwent surgery between January 2006 and December 2016 were retrospectively reviewed. In the extracapsular dissection group, a total of 44 parotid gland operations were performed in 40 patients. In the superficial parotidectomy group, a total of 34 parotid gland operations were performed in 32 patients. The operation time was significantly shorter in the extracapsular dissection group than in the superficial parotidectomy group (p<.001, Table 1). One patient in the extracapsular dissection group and five patients in the superficial parotidectomy group had postoperative facial nerve palsy. Recurrence of Warthin tumor in the tail portion of the parotid gland was identified in one patient who underwent superficial parotidectomy.

  4. Recent developments in high efficient freeze-drying of fruits and vegetables assisted by microwave: A review.

    PubMed

    Fan, Kai; Zhang, Min; Mujumdar, Arun S

    2018-01-10

    Microwave heating has been applied in the drying of high-value solids as it affords a number of advantages, including shorter drying time and better product quality. Freeze-drying at cryogenic temperature and extremely low pressure provides the advantage of high product quality, but at very high capital and operating costs due partly to very long drying time. Freeze-drying coupled with a microwave heat source speeds up the drying rate and yields good quality products provided the operating unit is designed and operated to achieve the potential for an absence of hot spot developments. This review is a survey of recent developments in the modeling and experimental results on microwave-assisted freeze-drying (MFD) over the past decade. Owing to the high costs involved, so far all applications are limited to small-scale operations for the drying of high-value foods such as fruits and vegetables. In order to promote industrial-scale applications for a broader range of products further research and development efforts are needed to offset the current limitations of the process. The needs and opportunities for future research and developments are outlined.

  5. Choice with frequently changing food rates and food ratios.

    PubMed

    Baum, William M; Davison, Michael

    2014-03-01

    In studies of operant choice, when one schedule of a concurrent pair is varied while the other is held constant, the constancy of the constant schedule may exert discriminative control over performance. In our earlier experiments, schedules varied reciprocally across components within sessions, so that while food ratio varied food rate remained constant. In the present experiment, we held one variable-interval (VI) schedule constant while varying the concurrent VI schedule within sessions. We studied five conditions, each with a different constant left VI schedule. On the right key, seven different VI schedules were presented in seven different unsignaled components. We analyzed performances at several different time scales. At the longest time scale, across conditions, behavior ratios varied with food ratios as would be expected from the generalized matching law. At shorter time scales, effects due to holding the left VI constant became more and more apparent, the shorter the time scale. In choice relations across components, preference for the left key leveled off as the right key became leaner. Interfood choice approximated strict matching for the varied right key, whereas interfood choice hardly varied at all for the constant left key. At the shortest time scale, visit patterns differed for the left and right keys. Much evidence indicated the development of a fix-and-sample pattern. In sum, the procedural difference made a large difference to performance, except for choice at the longest time scale and the fix-and-sample pattern at the shortest time scale. © Society for the Experimental Analysis of Behavior.

  6. CERT Resiliency Engineering Framework

    DTIC Science & Technology

    2007-03-01

    Heightened threat level and increasing uncertainty Shorter-lived skills 5 Operational risk management problems Poor planning and execution No asset...increasingly effective & efficient Today’s operational environment No operational boundaries Pervasive & rapidly changing technology Dynamic & expanding risks ...management function Seen as a technical function or responsibility Searching for magic bullet: CobiT , ITIL, ISO17799, NFP1600 Poorly defined and measured

  7. Surgical management of acute perforation of peptic ulcers. A single centre experience.

    PubMed

    Lemaitre, J; El Founas, W; Simoens, Chr; Ngongang, Chr; Smets, D; Mendes da Costa, P

    2005-01-01

    Acute perforation may occur in gastric and duodenal ulcers. During the past decade, the need for elective operation for peptic ulceration has decreased as medical treatment has improved. However, emergency operations for acute complications such as perforation or bleeding remain constant. Actually, the treatment of choice is simple suture-closure, with or without omentoplasty, and peritoneal lavage or even omentoplasty alone, associated with a high intravenous dose of inhibitors of the proton pump and Helicobacter pylori eradication, if needed. The standard treatment in our team is to perform a peritoneal lavage and drainage and a simple closure of the ulcer with an omentoplasty. A first retrospective analysis was made on data collected from 1996 to 2001 and we completed a prospective study from 2001 to 2003 to compare our results with our old data and with data collected from other teams. The mean age and the mean ASA score were similar in the two groups. For the majority of the patients, the diagnosis was made from symptoms and the presence of free abdominal air. The delay between arrival in the emergency room and the operating room was significantly shorter in the second group, but operating time was longer in this group. Morbidity was more frequent in the first group but mortality remained quite similar. Our results indicate that in a trained team the morbidity has decreased as the delay in surgery decreased and that the rate of diagnosis on plain abdominal film has increased. Laparoscopic suture of a perforated peptic ulcer is as safe as the open procedure but allows the surgeon to search for another cause of free air and offers the possibility, if conversion is needed, to perform a shorter laparotomy.

  8. Comparative study on usefulness of gentamycin-containing collagen implants in the treatment of patients with osteitis and osteomyelitis of the craniofacial skeleton.

    PubMed

    Zawadzki, Paweł J; Perkowski, Konrad; Kotlarski, Michał; Pietruczuk-Padzik, Anna; Chomicz, Lidia

    2017-05-11

    Introduction and objective. A reduction in incidences of peri-surgical complications due to infections is achieved by antibiotic prophylaxis The objective of the study was to assess the usefulness of gentamycin-containing collagen implants (GCCI) in the treatment of patients with osteitis and osteomyelitis of the craniofacial skeleton. Materials and method. The retrospective study included 103 patients with osteitis and osteomyelitis. 54 patients were treated intra-operatively with GCCI (Garamycin, EusaPharma, Europe). 49 patients were treated according to standard procedures. Light microscopy and in vitro culture techniques were applied for bacteria specific identification, and to investigate the resistance of detected microbiota to antibiotics. Patients received one dose of antibiotic pre-operatively. Post-operative antibiotic treatment was administered individually, according to clinical course and microbiological tests. The patients were followed-up on days 3, 7 and 14 after discharge for local complications; radiographic follow-up was performed 3, 6 and 12 months after surgery. Results. The course of post-operative antibiotic therapy was shorter in GCCI patients than in the control group (median 1 vs. 7 days); they also required shorter hospitalization (median 3 vs. 4 days). Implantation of GCCI significantly reduced the incidence of local complications (OR 0.30, 95%CI 0.11-0.83, p<0.0001), independently of the use of postoperative antibiotic therapy. On follow-up after 3-12 months, all patients presented with good soft tissue and bone healing. Conclusions. The results of this comparative study advocate the use of GCCI in osteomyelitis of various origin in oral and maxillofacial surgery, as they seemed to reduce the incidence of local complications, shorten antibiotic administration time and hospital stay.

  9. Root replacement using stentless valves in the small aortic root: a propensity score analysis.

    PubMed

    Kunihara, Takashi; Schmidt, Kathrin; Glombitza, Petra; Dzindzibadze, Vachtang; Lausberg, Henning; Schäfers, Hans-Joachim

    2006-10-01

    Root replacement using a stentless bioprosthesis may be the optimal approach to avoid patient-prosthesis mismatch in patients with a small aortic root. Primary root replacement, however, is considered to be associated with increased surgical risk. We compared early outcome of full root replacement with a stentless bioprosthesis with that of aortic valve replacement with a stented bioprosthesis using propensity score-matching analysis. Of 231 patients undergoing elective, first-time aortic valve replacement with a small root (< or = 22 mm), 120 patients were selected using propensity score-matching analysis. They underwent either root replacement using a 23-mm stentless bioprosthesis (stentless group, n = 60) or supra-annular aortic valve replacement using a 21-mm stented bioprosthesis (stented group, n = 60). Preoperative characteristics and frequency of concomitant operations were identical. Duration of operation (196 +/- 54 versus 174 +/- 49 minutes), cardiopulmonary bypass (112 +/- 36 versus 91 +/- 33 minutes), and aortic cross-clamping (76 +/- 21 versus 61 +/- 21 minutes) were significantly longer in the stentless group. However, the need for perioperative transfusion and the incidence of postoperative reexploration for bleeding (3% versus 8%) was lower, and ventilation time was shorter. Mean duration of intensive care and hospital stay were also significantly shorter (2.3 +/- 1.7 versus 4.0 +/- 3.9 days, 8.9 +/- 3.1 versus 12.4 +/- 5.7 days). In-hospital mortality was identical (5% each). No independent predictor for in-hospital mortality was identified. Full root replacement using a stentless bioprosthesis does not increase postoperative morbidity or mortality of aortic valve replacement and may be advantageous in patients with a small aortic root.

  10. Laparoscopic versus open major hepatectomy: a systematic review and meta-analysis of individual patient data.

    PubMed

    Kasai, Meidai; Cipriani, Federica; Gayet, Brice; Aldrighetti, Luca; Ratti, Francesca; Sarmiento, Juan M; Scatton, Olivier; Kim, Ki-Hun; Dagher, Ibrahim; Topal, Baki; Primrose, John; Nomi, Takeo; Fuks, David; Abu Hilal, Mohammad

    2018-05-01

    The role of laparoscopy for major hepatectomies remains a matter of development to be further assessed. The purpose of this study is to compare the short- and long-term outcomes between laparoscopic and open major hepatectomies meta-analyzing individual patient data from published comparative studies. All retrospective studies comparing between laparoscopic and open major hepatectomies published until March 2017 were identified independently by 2 reviewers by searching in PubMed and Cochrane Central Register of Controlled Trials. Individual patient data were sought from all selected studies. Postoperative outcomes, including intraoperative blood loss, operative time, hospital stay, postoperative complications, mortality rates, and long-term survival were analyzed. A total of 917 patients were divided into the laparoscopic (427) and open (490) groups from 8 selected studies. The hospital stay was significantly shorter, and the total morbidity was lower in the laparoscopic group. When classified by severity, the incidence of postoperative minor complications was lower; however, that of major complications was not significantly different. The operative time was longer in the laparoscopic group; however, intraoperative blood loss, perioperative mortality, and blood transfusions were comparable between the 2 groups. The overall survival in the patients with colorectal liver metastases and hepatocellular carcinoma was not significantly different between the 2 groups. Laparoscopic major hepatectomies offer some perioperative advantages, including fewer complications and shorter hospital stay, without increasing the blood loss volume and mortality. Whether these results can anticipate the outcomes in future randomized controlled trials has not been determined. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Flexible ureteroscopy versus laparoscopy for the treatment of patients who initially presented with obstructive pyelonephritis

    PubMed Central

    Sahin, Selcuk; Resorlu, Berkan; Eksi, Mithat; Aras, Bekir; Atar, Arda; Tugcu, Volkan

    2016-01-01

    Objective: To compare the safety and effectiveness of flexible ureteroscopy (F-URS) with transperitoneal laparoscopic ureterolithotomy (TPLU) in cases of obstructive pyelonephritis secondary to large proximal ureteral stones. Methods: A series of 42 patients presenting with obstructive pyelonephritis due to proximal ureteral stones larger than 1.5 cm were included from April 2006 to February 2015 in this comparative study. After drainage of pyonephrosis and resolution of sepsis, 22 patients treated with TPLU (Group I), and 20 patients were treated with F-URS (Group II). Preoperative patient and stone characteristics, procedure-related parameters and clinical outcomes were assessed for each group. Results: It was seen that both methods were effective in the treatment of large proximal ureteral stones. However TPLU provided a higher stone- free rate (100% vs 80%. p=0.043) and lower retreatment rate. There was no difference between the groups for the operative time and complication rate. On the other hand, patients treated with F-URS had less postoperative pain (p=0.008), a shorter hospital stay (p<0.001) and a faster return to daily activities (p<0.001). Conclusions: The results of our study show that both F-URS and TPLU are safe and effective surgical procedures for treatment of large proximal ureteral stones after controlling obstructive pyelonephritis. However, TPLU has a higher stone-free rate with comparable operating time and complication rate as compared to F-URS. On the other hand F-URS has the advantages of less postoperative pain, shorter hospital stay and faster return to daily activities. PMID:27375691

  12. A randomised trial comparing endometrial resection and abdominal hysterectomy for the treatment of menorrhagia.

    PubMed Central

    Gannon, M J; Holt, E M; Fairbank, J; Fitzgerald, M; Milne, M A; Crystal, A M; Greenhalf, J O

    1991-01-01

    OBJECTIVE--To determine the advantages and disadvantages of endometrial resection and abdominal hysterectomy for the surgical treatment of women with menorrhagia. DESIGN--Randomised study of two treatment groups with a minimum follow up of nine months. SETTING--Royal Berkshire Hospital, Reading. SUBJECTS--51 of 78 menorrhagic women without pelvic pathology who were on the waiting list for abdominal hysterectomy. TREATMENT--Endometrial resection or abdominal hysterectomy (according to randomisation). Endometrial resections were performed by an experienced hysteroscopic surgeon; hysterectomies were performed by two other gynaecological surgeons. MAIN OUTCOME MEASURES--Length of operating time, hospitalisation, recovery; cost of surgery; short term results of endometrial resection. RESULTS--Operating time was shorter for endometrial resection (median 30 (range 20-47) minutes) than for hysterectomy (50 (39-74) minutes). The hospital stay for endometrial resection (median 1 (range 1-3) days) was less than for hysterectomy (7 (5-12) days). Recovery after endometrial resection (median 16 (range 5-62) days) was shorter than after hysterectomy (58 (11-125) days). The cost was 407 pounds for endometrial resection and 1270 pounds for abdominal hysterectomy. Four women (16%) who did not have an acceptable improvement in symptoms after endometrial resection had repeat resections. No woman has required hysterectomy during a mean follow up of one year. CONCLUSION--For women with menorrhagia who have no pelvic pathology endometrial resection is a useful alternative to abdominal hysterectomy, with many short term benefits. Larger numbers and a longer follow up are needed to estimate the incidence of complications and the long term efficacy of endometrial resection. PMID:1760601

  13. Enrichment of denitrifying methanotrophic bacteria from municipal wastewater sludge in a membrane bioreactor at 20°C.

    PubMed

    Kampman, Christel; Temmink, Hardy; Hendrickx, Tim L G; Zeeman, Grietje; Buisman, Cees J N

    2014-06-15

    Simultaneous nitrogen and methane removal by the slow growing denitrifying methanotrophic bacterium 'Candidatus Methylomirabilis oxyfera' offers opportunities for a new approach to wastewater treatment. However, volumetric nitrite consumption rates should be increased by an order of magnitude before application in wastewater treatment becomes possible. A maximum volumetric nitrite consumption rate of 36 mg NO2(-)-N/L d was achieved in a membrane bioreactor inoculated with wastewater sludge and operated at 20°C. This rate is similar to maximum rates reported in literature, though it was thought that by strict biomass retention using membranes, higher rates would be achieved. In experiments lasting several years, growth was not stable: every experiment showed a decrease in activity after 1-2 years. The cause remains unknown. Rates increased after addition of copper and operating a membrane bioreactor at shorter hydraulic retention times. Further research should focus on long-term effects of copper addition and operation at hydraulic retention times in the order of hours using membrane bioreactors. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Laparoscopic Pediatric Inguinal Hernia Repair: Overview of "True Herniotomy" Technique and Review of Current Evidence.

    PubMed

    Feehan, Brendan P; Fromm, David S

    2017-05-01

    Inguinal hernia repair is one of the most commonly performed operations in the pediatric population. While the majority of pediatric surgeons routinely use laparoscopy in their practices, a relatively small number prefer a laparoscopic inguinal hernia repair over the traditional open repair. This article provides an overview of the three port laparoscopic technique for inguinal hernia repair, as well as a review of the current evidence with respect to visualization and identification of hernias, recurrence rates, operative times, complication rates, postoperative pain, and cosmesis. The laparoscopic repair presents a viable alternative to open repair and offers a number of benefits over the traditional approach. These include superior visualization of the relevant anatomy, ability to assess and repair a contralateral hernia, lower rates of metachronous hernia, shorter operative times in bilateral hernia, and the potential for lower complication rates and improved cosmesis. This is accomplished without increasing recurrence rates or postoperative pain. Further research comparing the different approaches, including standardization of techniques and large randomized controlled trials, will be needed to definitively determine which is superior. Copyright© South Dakota State Medical Association.

  15. Laparoscopic Adrenalectomy for Adrenal Tumors

    PubMed Central

    Chuan-yu, Sun; Yat-faat, Ho; Wei-hong, Ding; Yuan-cheng, Gou; Qing-feng, Hu; Ke, Xu; Bin, Gu; Guo-wei, Xia

    2014-01-01

    Objective. To evaluate the indication and the clinical value of laparoscopic adrenalectomy of different types of adrenal tumor. Methods. From 2009 to 2014, a total of 110 patients were diagnosed with adrenal benign tumor by CT scan and we performed laparoscopic adrenalectomy. The laparoscopic approach has been the procedure of choice for surgery of benign adrenal tumors, and the upper limit of tumor size was thought to be 6 cm. Results. 109 of 110 cases were successful; only one was converted to open surgery due to bleeding. The average operating time and intraoperative blood loss of pheochromocytoma were significantly more than the benign tumors (P < 0.05). After 3 months of follow-up, the preoperative symptoms were relieved and there was no recurrence. Conclusions. Laparoscopic adrenalectomy has the advantages of minimal invasion, less blood loss, fewer complications, quicker recovery, and shorter hospital stay. The full preparation before operation can decrease the average operating time and intraoperative blood loss of pheochromocytomas. Laparoscopic adrenalectomy should be considered as the first choice treatment for the resection of adrenal benign tumor. PMID:25132851

  16. Systematic review of perioperative outcomes and complications after open, laparoscopic and robot-assisted radical cystectomy.

    PubMed

    Palazzetti, A; Sanchez-Salas, R; Capogrosso, P; Barret, E; Cathala, N; Mombet, A; Prapotnich, D; Galiano, M; Rozet, F; Cathelineau, X

    2017-09-01

    Radical cystectomy and regional lymph node dissection is the standard treatment for localized muscle-invasive and for high-risk non-muscle-invasive bladder cancer, and represents one of the main surgical urologic procedures. The open surgical approach is still widely adopted, even if in the last two decades efforts have been made in order to evaluate if minimally invasive procedures, either laparoscopic or robot-assisted, might show a benefit compared to the standard technique. Open radical cystectomy is associated with a high complication rate, but data from the laparoscopic and robotic surgical series failed to demonstrate a clear reduction in post-operative complication rates compared to the open surgical series. Laparoscopic and robotic radical cystectomy show a reduction in blood loss, in-hospital stay and transfusion rates but a longer operative time, while open radical cystectomy is typically associated with a shorter operative time but with a longer in-hospital admission and possibly a higher rate of high grade complications. Copyright © 2016. Publicado por Elsevier España, S.L.U.

  17. Clinical efficacy of low-temperature radiofrequency ablation of pharyngolaryngeal cyst in 84 Chinese infants

    PubMed Central

    Wang, Zhinan; Zhang, Yamin; Ye, Yuhua; Yao, Wei; Xu, Zhongqiang; Xia, Zhongfang; Wang, Shufen; Zhou, Chengyong

    2017-01-01

    Abstract The aim of the study is to investigate the advantages and disadvantages of low-temperature radiofrequency ablation of pharyngolaryngeal cyst. The study population was composed of 84 children diagnosed with pharyngolaryngeal cyst who underwent surgical treatment at the Department of Otolaryngology, Wuhan Children's Hospital, Wuhan, China, between January 1984 and December 2013. All patients were operated using a self-retaining laryngoscope and were divided into 3 groups: traditional cystectomy group (N = 9), dynamic cutting system group (N = 18), and low-temperature radiofrequency ablation group (N = 57). Clinical outcomes were analyzed to assess the efficacy of low-temperature radiofrequency ablation in treatment of pharyngolaryngeal cyst. Compared with traditional cystectomy group or dynamic cutting system group, operation time was shorter, bleeding was less and one-year recurrence rate was much lower in low-temperature radiofrequency ablation group. However, operation time and bleeding was not statistically different between traditional cystectomy and dynamic cutting system group. Low-temperature radiofrequency ablation may be an effective substitute for treating pharyngolaryngeal cyst. PMID:29095253

  18. Surgical simulation in orthopaedic skills training.

    PubMed

    Atesok, Kivanc; Mabrey, Jay D; Jazrawi, Laith M; Egol, Kenneth A

    2012-07-01

    Mastering rapidly evolving orthopaedic surgical techniques requires a lengthy period of training. Current work-hour restrictions and cost pressures force trainees to face the challenge of acquiring more complex surgical skills in a shorter amount of time. As a result, alternative methods to improve the surgical skills of orthopaedic trainees outside the operating room have been developed. These methods include hands-on training in a laboratory setting using synthetic bones or cadaver models as well as software tools and computerized simulators that enable trainees to plan and simulate orthopaedic operations in a three-dimensional virtual environment. Laboratory-based training offers potential benefits in the development of basic surgical skills, such as using surgical tools and implants appropriately, achieving competency in procedures that have a steep learning curve, and assessing already acquired skills while minimizing concerns for patient safety, operating room time, and financial constraints. Current evidence supporting the educational advantages of surgical simulation in orthopaedic skills training is limited. Despite this, positive effects on the overall education of orthopaedic residents, and on maintaining the proficiency of practicing orthopaedic surgeons, are anticipated.

  19. Improved operative efficiency using a real-time MRI-guided stereotactic platform for laser amygdalohippocampotomy.

    PubMed

    Ho, Allen L; Sussman, Eric S; Pendharkar, Arjun V; Le, Scheherazade; Mantovani, Alessandra; Keebaugh, Alaine C; Drover, David R; Grant, Gerald A; Wintermark, Max; Halpern, Casey H

    2018-04-01

    OBJECTIVE MR-guided laser interstitial thermal therapy (MRgLITT) is a minimally invasive method for thermal destruction of benign or malignant tissue that has been used for selective amygdalohippocampal ablation for the treatment of temporal lobe epilepsy. The authors report their initial experience adopting a real-time MRI-guided stereotactic platform that allows for completion of the entire procedure in the MRI suite. METHODS Between October 2014 and May 2016, 17 patients with mesial temporal sclerosis were selected by a multidisciplinary epilepsy board to undergo a selective amygdalohippocampal ablation for temporal lobe epilepsy using MRgLITT. The first 9 patients underwent standard laser ablation in 2 phases (operating room [OR] and MRI suite), whereas the next 8 patients underwent laser ablation entirely in the MRI suite with the ClearPoint platform. A checklist specific to the real-time MRI-guided laser amydalohippocampal ablation was developed and used for each case. For both cohorts, clinical and operative information, including average case times and accuracy data, was collected and analyzed. RESULTS There was a learning curve associated with using this real-time MRI-guided system. However, operative times decreased in a linear fashion, as did total anesthesia time. In fact, the total mean patient procedure time was less in the MRI cohort (362.8 ± 86.6 minutes) than in the OR cohort (456.9 ± 80.7 minutes). The mean anesthesia time was significantly shorter in the MRI cohort (327.2 ± 79.9 minutes) than in the OR cohort (435.8 ± 78.4 minutes, p = 0.02). CONCLUSIONS The real-time MRI platform for MRgLITT can be adopted in an expedient manner. Completion of MRgLITT entirely in the MRI suite may lead to significant advantages in procedural times.

  20. Laparoscopic anterior versus endoscopic posterior approach for adrenalectomy: a shift to a new golden standard?

    PubMed

    Vrielink, O M; Wevers, K P; Kist, J W; Borel Rinkes, I H M; Hemmer, P H J; Vriens, M R; de Vries, J; Kruijff, S

    2017-08-01

    There has been an increased utilization of the posterior retroperitoneal approach (PRA) for adrenalectomy alongside the "classic" laparoscopic transabdominal technique (LTA). The aim of this study was to compare both procedures based on outcome variables at various ranges of tumor size. A retrospective analysis was performed on 204 laparoscopic transabdominal (UMC Groningen) and 57 retroperitoneal (UMC Utrecht) adrenalectomies between 1998 and 2013. We applied a univariate and multivariate regression analysis. Mann-Whitney and chi-squared tests were used to compare outcome variables between both approaches. Both mean operation time and median blood loss were significantly lower in the PRA group with 102.1 (SD 33.5) vs. 173.3 (SD 59.1) minutes (p < 0.001) and 0 (0-200) vs. 50 (0-1000) milliliters (p < 0.001), respectively. The shorter operation time in PRA was independent of tumor size. Complication rates were higher in the LTA (19.1%) compared to PRA (8.8%). There was no significant difference in recovery time between both approaches. Application of the PRA decreases operation time, blood loss, and complication rates compared to LTA. This might encourage institutions that use the LTA to start using PRA in patients with adrenal tumors, independent of tumor size.

  1. Thermalization time scales for WIMP capture by the Sun in effective theories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Widmark, A., E-mail: axel.widmark@fysik.su.se

    I study the process of dark matter capture by the Sun, under the assumption of a Weakly Interacting Massive Particle (WIMP), in the framework of non-relativistic effective field theory. Hypothetically, WIMPs from the galactic halo can scatter against atomic nuclei in the solar interior, settle to thermal equilibrium with the solar core and annihilate to produce an observable flux of neutrinos. In particular, I examine the thermalization process using Monte-Carlo integration of WIMP trajectories. I consider WIMPs in a mass range of 10–1000 GeV and WIMP-nucleon interaction operators with different dependence on spin and transferred momentum. I find that themore » density profiles of captured WIMPs are in accordance with a thermal profile described by the Sun's gravitational potential and core temperature. Depending on the operator that governs the interaction, the majority of the thermalization time is spent in either the solar interior or exterior. If normalizing the WIMP-nuclei interaction strength to a specific capture rate, I find that the thermalization time differs at most by 3 orders of magnitude between operators. In most cases of interest, the thermalization time is many orders of magnitude shorter than the age of the solar system.« less

  2. A comparison of sugammadex and neostigmine for reversal of rocuronium-induced neuromuscular blockade in children.

    PubMed

    Ammar, A S; Mahmoud, K M; Kasemy, Z A

    2017-04-01

    Sugammadex is designed to be a reversal agent for steroidal muscle relaxants. The current trial was aimed to compare between sugammadex and neostigmine concerning the recovery time from neuromuscular blockade. We hypothesised that sugammadex might have shorter recovery time than neostigmine. Sixty paediatric patients aged 2-10 years scheduled for lower abdominal surgeries were randomly assigned into two equal groups to receive 4 mg/kg sugammadex (Group S) or 0.35 mg/kg neostigmine and 0.02 mg/kg atropine (Group N) as a reversal agent for rocuronium at the end of surgery. Primary outcome was the recovery time [time from starting of sugammadex or neostigmine till reaching train of four (TOF) ratio> 0.9] whereas secondary outcomes included number of patients who needed another dose of sugammadex or neostigmine to reach TOF ratio> 0.9, extubation time (time from stoppage of anaesthetic inhalation until the patient fulfilled criteria for safe extubation, post-anaesthesia care unit (PACU) discharge time and post-operative adverse effects. The mean recovery and extubation times were significantly shorter (P = 0.002 and 0.005) in Group S compared with Group N (2.5 and 2.0 min vs. 12.6 min and 4.3 min respectively). In the Group N, eight patients needed another reversal dose compared with one patient in Group S (P = 0.035). PACU discharge time showed no significant difference between both groups. Incidence of nausea, vomiting, tachycardia, and dry mouth were significantly higher in Group N. Sugammadex administration in children resulted in faster recovery and extubation times and lower incidence of adverse events compared with neostigmine. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  3. Increased risk environment for emergency general surgery in the context of regionalization and specialization.

    PubMed

    Beecher, S; O'Leary, D P; McLaughlin, R

    2015-09-01

    The pressures on tertiary hospitals with increased volume and complexity related to regionalization and specialization has impacted upon availability of operating theatres with consequent displacement of emergencies to high risk out of hours settings. A retrospective review of an electronic emergency theatre list prospectively maintained database was performed over a two year period. Data gathered included type of operation performed, Time to Theatre (TTT), operation start time and length of stay (LOS). Of 7041 emergency operations 25% were performed out of hours. 2949 patient had general surgical emergency procedures with 910 (30%) performed out of hours. 53% of all emergency laparotomies and 54% of appendicectomies were out of hours. 57% of cases operated on out of hours had been awaiting surgery during the day. Mean TTT was shorter for those admitted at the weekend compared to those admitted during the week (15.6 vs 24.9 h) (p < 0.0001). The majority of major emergency surgery is performed out of hours in a way unfavorable to good clinical outcomes. It is of concern that more than half of the most life threating procedures involving laparotomy, take place out of hours. Regionalization needs to be accompanied by infrastructure planning to accommodate emergency surgery. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  4. Mechanisms of Exhaust Pollutants and Plume Formation in Continuous Combustion.

    DTIC Science & Technology

    1984-11-30

    drop swirler. A swirled air inlet decreased flame length . Two modes of operation were observed. At higher fuel loadings, reaction could be initiated...and maintained in the recirculation zone in the shadow of the step. The net result was a shorter overall flame length . The low-pressure drop swirler...yielded a shorter flame length relative to the higher pressure drop devices. - • u mmm m -m~amkn Jm• ml AM mmmmm TABLE OF CONTENTS Section Title Page

  5. Pressurization and expulsion of a flightweight liquid hydrogen tank

    NASA Technical Reports Server (NTRS)

    Vandresar, N. T.; Stochl, R. J.

    1993-01-01

    Experimental results are presented for pressurization and expulsion of a flight-weight 4.89 cu m liquid hydrogen storage tank under normal gravity conditions. Pressurization and expulsion times are parametrically varied to study the effects of longer transfer times expected in future space flight applications. It is found that the increase in pressurant consumption with increased operational time is significant at shorter pressurization or expulsion durations and diminishes as the duration lengthens. Gas-to-wall heat transfer in the ullage is the dominant mode of energy exchange, with more than 50 percent of the pressurant energy being lost to tank wall heating in expulsions and the long duration pressurizations. Advanced data analysis will require a multidimensional approach combined with improved measurement capabilities of liquid-vapor interfacial transport phenomena.

  6. Electron microscopy of electromagnetic waveforms.

    PubMed

    Ryabov, A; Baum, P

    2016-07-22

    Rapidly changing electromagnetic fields are the basis of almost any photonic or electronic device operation. We report how electron microscopy can measure collective carrier motion and fields with subcycle and subwavelength resolution. A collimated beam of femtosecond electron pulses passes through a metamaterial resonator that is previously excited with a single-cycle electromagnetic pulse. If the probing electrons are shorter in duration than half a field cycle, then time-frozen Lorentz forces distort the images quasi-classically and with subcycle time resolution. A pump-probe sequence reveals in a movie the sample's oscillating electromagnetic field vectors with time, phase, amplitude, and polarization information. This waveform electron microscopy can be used to visualize electrodynamic phenomena in devices as small and fast as available. Copyright © 2016, American Association for the Advancement of Science.

  7. Laparoscopic versus open repair for perforated peptic ulcer: A meta analysis of randomized controlled trials.

    PubMed

    Tan, Shanjun; Wu, Guohao; Zhuang, Qiulin; Xi, Qiulei; Meng, Qingyang; Jiang, Yi; Han, Yusong; Yu, Chao; Yu, Zhen; Li, Ning

    2016-09-01

    The role of laparoscopic surgery in the repair for peptic ulcer disease is unclear. The present study aimed to compare the safety and efficacy of laparoscopic versus open repair for peptic ulcer disease. Randomized controlled trials (RCTs) comparing laparoscopic versus open repair for peptic ulcer disease were identified from MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and references of identified articles and relevant reviews. Primary outcomes were postoperative complications, mortality, and reoperation. Secondary outcomes were operative time, postoperative pain, postoperative hospital stay, nasogastric tube duration, and time to resume diet. Statistical analysis was carried out by Review Manage software. Five RCTs investigating a total of 549 patients, of whom, 279 received laparoscopic repair and 270 received open repair, were included in the final analysis. There were no significant differences between these two procedures in some primary outcomes including overal postoperative complication rate, mortality, and reoperation rate. Subcategory analysis of postoperative complications showed that laparoscopic repair had also similar rates of repair site leakage, intra-abdominal abscess, postoperative ileus, pneumonia, and urinary tract infection as open surgery, except of the lower surgical site infection rate (P < 0.05). In addition, there were also no significant differences between these two procedures in some second outcomes including operative time, postoperative hospital stay, and time to resume diet, but laparoscopic repair had shorter nasogastric tube duration (P < 0.05) and less postoperative pain (P < 0.05) than open surgery. Laparoscopic surgery is comparable with open surgery in the setting of repair for perforated peptic ulcer. The obvious advantages of laparoscopic surgery are the lower surgical site infection rate, shorter nasogastric tube duration and less postoperative pain. However, more higher quality studies should be undertaken to further assess the safety and efficacy of laparoscopic repair for peptic ulcer disease. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  8. A Comparison of Robotic, Laparoscopic and Open Partial Nephrectomy

    PubMed Central

    Lucas, Steven M.; Mellon, Matthew J.; Erntsberger, Luke

    2012-01-01

    Introduction: Comparison of treatments for partial nephrectomy is limited by case selection. We compared robotic (RPN), laparoscopic (LPN), and open partial nephrectomy (OPN), controlling for tumor size, patient age, sex, and nephrometry score. Methods: RPN, LPN, and OPN procedures between March 2003 and March 2010 were reviewed. All RPN and LPN were included, and 2 OPN were matched for each RPN in tumor size (±0.5cm), patient age (±10 y), sex, and nephrometry score. Perioperative outcomes were compared. Results: Ninety-six partial nephrectomy procedures were reviewed: 27 RPN, 15 LPN, and 54 OPN. RPN, LPN, and OPN had similar median tumor size (2.4, 2.2, and 2.3cm, respectively), nephrometry score (6.0 each), and preoperative glomerular filtration rate (71.5, 84.6, and 77.0 mL/min/1.73m2, respectively). Blood loss was higher for OPN (250 mL) than for RPN or LPN (100 mL), P < .001. Operative time was shorter in OPN (147 min) than in RPN (190 min) or LPN (195 min), P < .001. Median warm ischemia time was shorter for OPN (12.0 min) than for RPN (25.0 min) or LPN (29.5 min), P < .05. Cold ischemia time for OPN was 25.0 min. A 10% glomerular filtration rate decline occurred in 10 RPN, 5 LPN, and 29 OPN cases (P = .252). Median hospital stay for LPN and RPN was 2.0 d versus 3.0 d for OPN (P < .001). Urine leak occurred in 1 RPN and 3 OPN cases. Postoperative complications occurred in 4 RPN (3 were Clavien grade 2 or less), 1 LPN (grade 1), and 7 OPN (6 were grade 2 or less) cases. Conclusion: Renal function preservation and complications are similar for each treatment modality. OPN offers faster operative and ischemia times at the expense of greater blood loss and hospital stay. PMID:23484568

  9. Incidental De Garengeot’s hernia: A case report of dual pathology to remember

    PubMed Central

    Whitehead-Clarke, Thomas; Parampalli, Umesh; Bhardwaj, Rakesh

    2015-01-01

    Introduction A De Garengeot’s hernia is the very rare dual pathology of a vermiform appendix within a femoral hernia. Presentation of case We discuss the rare case of a 62 year old female who presented as an emergency with a strangulated femoral hernia. Within the hernia sac a partly necrotic vermiform appendix was discovered. The patient successfully underwent an appendicectomy and repair of her femoral hernia. The post-operative period was uneventful, with no further issues at follow-up. Discussion Our case report displays the successful treatment of a De Garengeot's hernia as an emergency admission, with a shorter than average admission time, and no post-operative complications. Conclusion This is a rare case of dual pathology, of which we believe there are few published cases. PMID:26520035

  10. Special features of total knee replacement in hemophilia.

    PubMed

    Rodriguez-Merchan, Emerito Carlos

    2013-12-01

    Total knee replacement is an operation frequently needed by hemophilia patients, which greatly improves their quality of life. This operation, however, carries a higher risk of bleeding and infection for hemophiliacs than it does for osteoarthritis sufferers. It is advisable to implant prosthetic components using antibiotic-loaded cement. It is essential to maintain a level of 100% of the replacement clotting factor for 2 weeks. Hematological treatment must be established, depending on the patient's factor levels and other pharmacokinetic parameters such as recovery and half-life, optimal doses and treatment time. It is preferable to use general anesthesia due to the risk of spinal bleeding. The lifespan of total knee replacement in hemophilic patients is shorter than in patients with osteoarthritis because of the increased risk of infection.

  11. A randomized comparative study on modified Joel-Cohen incision versus Pfannenstiel incision for cesarean section

    PubMed Central

    Saha, Shyama Prasad; Bhattarcharjee, Nabendu; Das Mahanta, Sabysachi; Naskar, Animesh; Bhattacharyya, Sanjoy Kumar

    2013-01-01

    Objective: Pfanennstiel incision is the most commonly used incision for cesarean section, but may not be the best. This study compared the modified Joel-Cohen incision with the Pfannenstiel incision to evaluate whether techniques to open the abdomen might influence operative time, and maternal and neonatal outcomes. Material and Methods: In a randomized comparative trial, 302 women with gestational age >34 weeks, requiring cesarean section, were randomly assigned to either modified Joel-Cohen incision or Pfannenstiel incision for entry into the peritoneal cavity. The primary outcome measure was total time required for performing operation and secondary outcome measures were baby extraction time, number of haemostatic procedures used in the abdominal wall, postoperative morbidity, postoperative hospital stay and neonatal outcome. Results: Mean total operative time was significantly less in the modified Joel-Cohen group as compared to the Pfannenstiel group (29.81 vs 32.67 min, p<0.0001, 95%CI=2.253 to 3.467). Time taken to deliver the baby and haemostatic procedures required during operation were also significantly less in the modified Joel-Cohen group as compared to the Pfannenstiel group. Requirement of strong analgesics was higher in the Pfannenstiel group (53.64% vs 21.85%, p<0.0001). There was no statically significant difference in the incidence of postoperative wound complications but postoperative stay in hospital was significantly less in the modified Joel-Cohen group (p=0.002). Neonatal outcomes were similar in both groups. Conclusion: The modified Joel-Cohen incision for entry into peritoneal cavity during cesarean section is associated with reduced mean total operative and baby extraction times with less postoperative pain and shorter hospital stay, which may be beneficial and cost effective. PMID:24592067

  12. [Clinical effect of circumcision stapler in the treatment of phimosis and redundant prepuce].

    PubMed

    Huo, Zhong-chao; Liu, Gang; Wang, Wei; He, Da-guang; Yu, Hai; Fan, Wen-ju; Zhong, Zheng

    2015-04-01

    To observe the clinical effect and safety of circumcision stapler in the treatment of phimosis and redundant prepuce. We treated 120 patients with redundant prepuce or phimosis using circumcision stapler and another 60 by conventional dorsal-incision circumcision. We observed intraoperative blood loss, operation time, postoperative pain, wound healing time, cosmetic appearance of the penis, and postoperative complications and compared them between the two groups of patients. Stapler circumcision showed obvious advantages over the conventional method in intraoperative blood loss ([2. 3 ± 1. 3] vs [15.6 ± 2.9] ml), operation time ([7.1 ± 1.4] vs [22.6 ± 4.6] min), wound healing time ([12.0 ± 2.9] as [16.3 ± 3. 1] d), postoperative pain score (1. 9 ± 1. 3 vs 5. 2 ± 1. 7), incision edema, and cosmetic appearance of the penis (all P <0. 05). Besides, stapler circumcision exempted the patients from stitch-removal pain. However, the incidence rate of postoperative local ecchymosis was significantly higher in the circumcision stapler group than in the conventional circumcision group (20. 8% vs 8. 3% , P <0. 05). Circumcision stapler, with its advantages of easier manipulation, shorter operation time, better cosmetic penile appearance, less pain, and fewer complications, is superior to conventional circumcision in the treatment of phimosis and redundant prepuce.

  13. [Double localization of pancreatic insulinoma. Diagnostic and therapeutic difficulties].

    PubMed

    Ungureanu, C D; David, L; Braşoveanu, V; Herlea, V; Coculescu, M; Popescu, I

    2005-01-01

    Insulinomas are the most common cause of hypoglycemia resulting from endogenous hyperinsulinism. Because most of insulinomas are less than 2 cm in size and rarely they not may be visible by CT scan or transabdominal ultrasonography. Intraoperative ultrasonography may be a solution. Although as surgical method is preferred enucleation because operative time is shorter and easier and the low frequency postoperative complications, pancreaticoduodenectomy Whipple is indicated in selected cases. We report a case of double insulinoma located in the head of the pancreas in which the diagnosis and surgical treatment presented difficulties which determined a particular clinical evolution.

  14. [Comparative trial between traditional cesarean section and Misgav-Ladach technique].

    PubMed

    Gutiérrez, José Gabriel Tamayo; Coló, José Antonio Sereno; Arreola, María Sandra Huape

    2008-02-01

    The cesarean section was designed to extract to the neoborn, when the childbirth becomes difficult by the natural routes. The institutional obstetrical work demands long surgical time and high raw materials; therefore, simpler procedures must be implemented. To compare traditional cesarean section vs Misgav-Ladach technique to assess surgical time, and hospital stay and costs. Forty-eight pregnant patients at term with obstetrical indication for cesarean delivery were randomized in two groups: 24 were submitted to traditional cesarean and 24 to Misgav-Ladach technique. The outcomes included surgical time, bleeding, amount of sutures employed, pain intensity and some others adverse effects. The surgical time with Misgav-Ladach technique was shorter compared with traditional cesarean section, bleeding was consistently lesser and pain was also low. None adverse effects were registered in both groups. Although short follow-up showed significant operative time reduction and less bleeding, longer follow-up should be desirable in order to confirm no abdominal adhesions.

  15. Endotracheal Intubation With and Without Night Vision Goggles in a Helicopter and Emergency Room Setting: A Manikin Study.

    PubMed

    Gellerfors, Mikael; Svensén, Christer; Linde, Joacim; Lossius, Hans Morten; Gryth, Dan

    2015-09-01

    Securing the airway by endotracheal intubation (ETI) is a key issue in prehospital critical care. Night vision goggles (NVG) are used by personnel operating in low-light environments. We examined the feasibility of an anesthesiologist performed ETI using NVG in a helicopter setting. Twelve anesthesiologists performed ETI on a manikin in an emergency room (ER) setting and two helicopter settings, with randomization to either rotary wing daylight (RW-D) or rotary wing in total darkness using binocular NVG (RW-NVG). Primary endpoint was intubation time. Secondary endpoints included success rate, Cormack-Lehane (CL) score, and subjective difficulty according to the Visual Analoge Scale (VAS). The median intubation time was shorter for the RW-D compared to the RW-NVG setting (16.5 seconds vs. 30.0 seconds; p = 0,03). We found no difference in median intubation time for the ER and RW-D settings (16.8 seconds vs. 16.5 seconds; p = 0.91). For all scenarios, success rate was 100%. CL and VAS varied between the ER setting (CL 1.8, VAS 2.8), RW-D setting (CL 2.0, VAS 3.0), and RW-NVG setting (CL 3.0, VAS 6.5). This study suggests that anesthesiologists successfully and quickly can perform ETI in a helicopter setting both in daylight and in darkness using binocular NVG, but with shorter intubation times in daylight. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.

  16. Robotic vs. Retropubic radical prostatectomy in prostate cancer: A systematic review and a meta-analysis update

    PubMed Central

    Chen, Hongbo; Chen, Zhiqiang; Xu, Hua; Ye, Zhangqun

    2017-01-01

    CONTEXT The safety and feasibility of robotic-assisted radical prostatectomy (RARP) compared with retropubic radical prostatectomy(RRP) is debated. Recently, a number of large-scale and high-quality studies have been conducted. OBJECTIVE To obtain a more valid assessment, we update the meta-analysis of RARP compared with RRP to assessed its safety and feasibility in treatment of prostate cancer. METHODS A systematic search of Medline, Embase, Pubmed, and the Cochrane Library was performed to identify studies that compared RARP with RRP. Outcomes of interest included perioperative, pathologic variables and complications. RESULTS 78 studies assessing RARP vs. RRP were included for meta-analysis. Although patients underwent RRP have shorter operative time than RARP (WMD: 39.85 minutes; P < 0.001), patients underwent RARP have less intraoperative blood loss (WMD = -507.67ml; P < 0.001), lower blood transfusion rates (OR = 0.13; P < 0.001), shorter time to remove catheter (WMD = -3.04day; P < 0.001), shorter hospital stay (WMD = -1.62day; P < 0.001), lower PSM rates (OR:0.88; P = 0.04), fewer positive lymph nodes (OR:0.45;P < 0.001), fewer overall complications (OR:0.43; P < 0.001), higher 3- and 12-mo potent recovery rate (OR:3.19;P = 0.02; OR:2.37; P = 0.005, respectively), and lower readmission rate (OR:0.70, P = 0.03). The biochemical recurrence free survival of RARP is better than RRP (OR:1.33, P = 0.04). All the other calculated results are similar between the two groups. CONCLUSIONS Our results indicate that RARP appears to be safe and effective to its counterpart RRP in selected patients. PMID:27852051

  17. Learning curves and perioperative outcomes after endoscopic enucleation of the prostate: a comparison between GreenLight 532-nm and holmium lasers.

    PubMed

    Peyronnet, Benoit; Robert, Grégoire; Comat, Vincent; Rouprêt, Morgan; Gomez-Sancha, Fernando; Cornu, Jean-Nicolas; Misrai, Vincent

    2017-06-01

    To compare the learning curves, perioperative and early functional outcomes after HoLEP and GreenLEP. Data from the first 100 consecutive cases treated by GreenLEP and HoLEP by two surgeons were prospectively collected from dedicated databases and analysed retrospectively. En-bloc GreenLEP and two-lobar HoLEP enucleations were conducted using the GreenLight HPS™ 2090 laser and Lumenis™ holmium laser. Patients' characteristics, perioperative outcomes and functional outcomes after 1, 3 and 6 months were compared between groups. Total energy delivered and operative times were significantly shorter for GreenLEP (58 vs. 110 kJ, p < 0.0001; 60 vs. 90 min, p < 0.0001). Operative time reached a plateau after 30 procedures in each group. Length of catheterization and hospital stay were significantly shorter in the HoLEP group (2 vs. 1 day, p < 0.0001; 2 vs. 1 day, p < 0.0001). Postoperative complications were comparable between GreenLEP and HoLEP (19 vs. 25 %; p = 0.13). There was a greater increase of Q max at 3 months and a greater IPSS decrease at 1 month for GreenLEP, whereas decreases in IPSS and IPSS-Q8 at 6 months were greater for HoLEP. Transient stress urinary incontinence was comparable between both groups (6 vs. 9 % at 3 months; p = 0.42). Pentafecta was achieved in four consecutive patients after the 18th and the 40th procedure in the GreenLEP and HoLEP group, respectively. Learning curves ranged from 14 to 30 cases for GreenLEP and 22 to 40 cases for HoLEP. Learning curves of GreenLEP and HoLEP provided roughly similar peri-operative and short-term functional outcomes.

  18. New Technique for Caesarean Section.

    PubMed

    Vejnović, T R; Costa, S D; Ignatov, A

    2012-09-01

    Caesarean section is one of the most common operations worldwide and more than 30 % of procedures in perinatal centres in Germany are caesarean sections. In the last few years the technique used for caesarean sections has been simplified, resulting in a lower postoperative morbidity. But persistent problems associated with all caesarean section techniques include high intraoperative loss of blood, the risk of injury to the child during uterotomy and postoperative wound dehiscence of the uterine scar. We present here a modification of the most common Misgav-Ladach method. The initial skin incision is done along the natural skin folds and is extended intraoperatively depending on the circumference of the baby's head. After blunt expansion of the uterine incision using an anatomical forceps, the distal uterine wall is pushed behind the baby's head. The baby's head is rotated into the occipito-anterior or posterior position and delivery occurs through the application of gentle pressure on the uterine fundus. Closure of the uterotomy is done using 2 continuous sutures, which are then knotted together resulting in a short double-layer closure. The two ends of the skin suture are left open to allow for natural drainage. Our experience at the University Gynaecological Hospitals in Novi Sad and Magdeburg has shown that this modification is associated with shorter operating times, minimal blood loss and shorter in-hospital stay of patients as well as high rates of patient satisfaction.

  19. 77 FR 7640 - Self-Regulatory Organizations; BATS Y-Exchange, Inc.; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-13

    ... 30 days after the date of the filing, or such shorter time as the Commission may designate, it has...-4(f)(6)(iii) \\8\\ permits the Commission to designate a shorter time if such action is consistent... without further delay. The Exchange notes that the introduction of the additional optional variation of...

  20. 77 FR 7642 - Self-Regulatory Organizations; BATS Exchange, Inc.; Notice of Filing and Immediate Effectiveness...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-13

    ... 30 days after the date of the filing, or such shorter time as the Commission may designate, it has...-4(f)(6)(iii) \\8\\ permits the Commission to designate a shorter time if such action is consistent... trading costs without further delay. The Exchange notes that the introduction of the additional optional...

  1. [EFFECTIVENESS COMPARISON OF PROXIMAL FEMORAL NAIL ANTI-ROTATION IN SUPINE "SCISSORS" POSITION AND IN LITHOTOMY POSITION TO TREAT FEMORAL INTERTROCHANTERIC FRACTURES OF OLD PATIENTS].

    PubMed

    Du, Shihao; Yin, Fei; Wei, Xuming; Song, Sheng; Gu, Sanjun; Sun, Zhenzhong; Rui, Yongjun

    2016-02-01

    To compare the effectiveness of proximal femoral nail anti-rotation (PFNA) between in the supine "scissors" position and in the lithotomy position for treating femoral intertrochanteric fractures of old patients. A retrospective study was performed on 58 patients with femoral intertrochanteric fractures treated with PFNA between January 2013 and January 2015. Fracture was treated with PFNA in the lithotomy position in 28 cases (group A) and in the supine "scissors" position in 30 cases (group B). There was no significant difference in gender, age, side, cause of injury, fracture type, and interval from injury to operation between 2 groups (P>0.05). The incision length, operation time, perspective times, intraoperative blood loss, complications, and fracture healing time were recorded; Harris hip score was used to access the effectiveness. The wound healed by first intention without infection, pressure sores, deep vein thrombosis of lower extremity, and other complications. There was no significant difference in incision length between 2 groups (t=1.313, P=0.212). Group B was significantly better than group A in operation time, perspective times, and intraoperative blood loss (P<0.05). All patients were followed up 10-31 months (mean, 15.3 months). Stretch injury at normal side and perineal discomfort occurred in 1 case and 5 cases of group A respectively, and no nonunion and other complications was observed in the other patients. There was no significant difference in fracture healing time and Harris hip score at last follow-up between 2 groups (P>0.05). PFNA in the supine "scissors" position has exact effectiveness and advantages of shorter operation time, less intraoperative blood loss, less perspective times, and fewer complications.

  2. [Unidirectional versus multidirectional palmar locking osteosynthesis of unstable distal radius fractures: comparative analysis with LDR 2.4 mm versus 2.7 mm matrix-Smartlock].

    PubMed

    Hakimi, M; Jungbluth, P; Gehrmann, S; Nowak, J; Windolf, J; Wild, M

    2010-03-01

    Due to advances in the development of the unidirectional locking plates there is now an increased use of multidirectional palmar locking plates in the treatment of distal radius factures. The purpose of this study was to evaluate a possible improvement of the treatment and results. This prospective cohort study investigated 40 patients with C1 and C2 Colles' fractures who had been treated with unidirectional and multidirectional locking plates. The average time for the follow-up examinations was 12.3 months (range 12-15 months) after surgery. The intra-operative functional (neutral-zero method), radiological and subjective (DASH score, VAS) results were evaluated. The intra-operative fluoroscopy time of the unidirectional group was 58 s shorter compared to the multidirectional group. All fractures healed without any complication. The radiological, subjective (DASH score) and objective results for both groups were good and showed no differences. Unidirectional palmar locking plates are equally suited for the therapy of C1 and C2 fractures as multidirectional palmar locking plates but multidirectional plates require a longer fluoroscopy time.

  3. [Video-laparoscopic excision of pancreatic insulinoma. Experience with 3 cases].

    PubMed

    Pugliese, Raffaele; Boniardi, Marco; Sansonna, Fabio; Maggioni, Dario; Scandroglio, Ildo; Costanzi, Andrea; Rapetti, Rosangela; Oppizzi, Giuseppe; Loli, Paola

    2008-01-01

    Laparoscopic treatment of lesions of the distal pancreas has gained favour worldwide in the last decade. The objective of this study was to analyze 3 cases of insulinoma successfully treated with the laparoscopic approach. From 2000 to 2007 in our institution 3 patients with insulinoma of the left pancreas were treated with a laparoscopic approach. The insulinoma was diagnosed by helical CT scan, Two cases were treated by left pancreatectomy and one by enucleation. The resections were achieved by laparoscopy with no conversion to laparotomy. There were no intraoperative complications. Average blood loss was 180 mi (range: 150-350). Mean operative time was 232 minutes (range: 225-240). Morbidity consisted in one mild pancreatic fistula after left pancreatectomy that was healed by conservative treatment after 24 days. The mean hospital stay was 13 days (range: 10-20). During the follow-up insulinoma symptoms have disappeared in all patients. This study confirms the feasibility of laparoscopic resection for insulinoma. Operative times were quite acceptable and the conversion rate was nil. Times to oral intake and walking were shorter than after open surgery, as was the mean postoperative hospital stay.

  4. Time between the first and second operations for staged total knee arthroplasties when the interval is determined by the patient.

    PubMed

    Ishii, Yoshinori; Noguchi, Hideo; Takeda, Mitsuhiro; Sato, Junko; Toyabe, Shin-Ichi

    2014-01-01

    The purpose of this study was to evaluate the interval between the first and second operations for staged total knee arthroplasties (TKAs) in patients with bilateral knee osteoarthritis. Depending on satisfactory preoperative health status, the patients determined the timing of the second operation. We also analysed correlations between the interval and patient characteristics. Eighty-six patients with bilateral knee osteoarthritis were analysed. The mean follow-up time from the first TKA was 96 months. The side of the first TKA was chosen by the patients. The timing of the second TKA was determined by the patients, depending on their perceived ability to tolerate the additional pain and limitations to activities of daily living. The median interval between the first and second operations was 12.5 months, with a range of 2 to 113 months. In 43 (50%) patients, the interval was <12 months. There was no difference in the interval between females and males (p=0.861), and no correlation between the interval and body mass index or age. There was weak correlation between the year of the first TKA and the interval (R=-0.251, p=0.020), with the interval getting significantly shorter as the years progressed (p=0.032). The median interval between the first and second operations in patients who underwent staged TKAs for bilateral knee osteoarthritis was about 1 year. The results of the current study may help patients and physicians to plan effective treatment strategies for staged TKAs. Level II. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Long-term experience and outcomes of robotic assisted laparoscopic pyeloplasty in children and young adults.

    PubMed

    Minnillo, Brian J; Cruz, Jose A S; Sayao, Rogerio H; Passerotti, Carlo C; Houck, Constance S; Meier, Petra M; Borer, Joseph G; Diamond, David A; Retik, Alan B; Nguyen, Hiep T

    2011-04-01

    Laparoscopic pyeloplasty is one of the more common robotic assisted procedures performed in children. However, data regarding long-term experience and clinical outcomes for this procedure are limited. We evaluated the long-term outcomes in a large series of patients undergoing robotic assisted laparoscopic pyeloplasty at a teaching institution, and the effect of a collaborative program between the robotic surgeons, surgical nurses and anesthesiologists on overall operative time. We retrospectively reviewed 155 patients who underwent robotic assisted laparoscopic pyeloplasty between 2002 and 2009. Operative data, including surgical approach, type of procedure, total and specific operative times and placement of ureteral stents, were determined. Postoperative outcome measurements, including duration of hospital stay, duration of Foley catheter drainage, radiological findings and any subsequent complications, were assessed. Mean operative time and length of hospitalization decreased significantly by the end of the study. At a mean followup of 31.7 months the primary success rate was 96% (hydronephrosis was improved in 85% of patients and stable in 11%). The complication rate was 11%, and recurrent obstruction requiring redo robotic assisted laparoscopic pyeloplasty or open pyeloplasty developed in 3% of patients. Success rate and complication rate were unchanged during the study period. This study confirms that even within the confines of a pediatric urology training program successful collaboration between robotic surgeons, surgical nurses and anesthesiologists can lead to shorter operative times and hospital stays. Long-term surgical success and complication rates were comparable to open surgery. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Reclosing operation characteristics of the flux-coupling type SFCL in a single-line-to ground fault

    NASA Astrophysics Data System (ADS)

    Jung, B. I.; Cho, Y. S.; Choi, H. S.; Ha, K. H.; Choi, S. G.; Chul, D. C.; Sung, T. H.

    2011-11-01

    The recloser that is used in distribution systems is a relay system that behaves sequentially to protect power systems from transient and continuous faults. This reclosing operation of the recloser can improve the reliability and stability of the power supply. For cooperation with this recloser, the superconducting fault current limiter (SFCL) must properly perform the reclosing operation. This paper analyzed the reclosing operation characteristics of the three-phase flux-coupling type SFCL in the event of a ground fault. The fault current limiting characteristics according to the changing number of turns of the primary and secondary coils were examined. As the number of turns of the first coil increased, the first maximum fault current decreased. Furthermore, the voltage of the quenched superconducting element also decreased. This means that the power burden of the superconducting element decreases based on the increasing number of turns of the primary coil. The fault current limiting characteristic of the SFCL according to the reclosing time limited the fault current within a 0.5 cycles (8 ms), which is shorter than the closing time of the recloser. In other words, the superconducting element returned to the superconducting state before the second fault and normally performed the fault current limiting operation. If the SFCL did not recover before the recloser reclosing time, the normal current that was flowing in the transmission line after the recovery of the SFCL from the fault would have been limited and would have caused losses. Therefore, the fast recovery time of a SFCL is critical to its cooperation with the protection system.

  7. The effect of intermittent operation on a wind-powered membrane system for brackish water desalination.

    PubMed

    Park, G L; Schäfer, A I; Richards, B S

    2012-01-01

    Renewable energy powered membrane systems that are directly-connected must take account of both the inherent fluctuations and the intermittency of the energy resource. In order to determine the effect of intermittent operation, a membrane system was tested with variables of (i) amplitude from 60 to 300 W and (ii) length of time with no power from 0.5 to 3 min. This was performed over one hour periods with six on/off cycles to simulate the system operating under intermittent operation for short periods of time when directly-connected to a small wind turbine. The setup used a Filmtec BW30-4040 brackish water reverse osmosis membrane with feed waters of 2,750 mg/L and 5,500 mg/L NaCl. The results showed that the membrane system produced potable water under the majority of intermittency experiments performed. There was a relatively large increase in the average salt concentration of the permeate, especially when the system was off for shorter periods of time (0.5-1 min). Longer periods of no power (1-3 min) did not have as significant an effect on the average water quality. This is important when the need for energy buffering or short term storage is considered for these systems as it shows the potential for improving the overall flux and water quality using temporary energy storage.

  8. Mini vs standard percutaneous nephrolithotomy for renal stones: a comparative study.

    PubMed

    ElSheemy, Mohammed S; Elmarakbi, Akram A; Hytham, Mohammed; Ibrahim, Hamdy; Khadgi, Sanjay; Al-Kandari, Ahmed M

    2018-03-16

    To compare the outcome of mini-percutaneous nephrolithotomy (Mini-PNL) versus standard-PNL for renal stones. Retrospective study was performed between March 2010 and May 2013 for patients treated by Mini-PNL or standard-PNL through 18 and 30 Fr tracts, respectively, using pneumatic lithotripsy. Semirigid ureteroscope (8.5/11.5 Fr) was used for Mini-PNL and 24 Fr nephroscope for standard-PNL. Both groups were compared in stone free rate(SFR), complications and operative time using Student-t, Mann-Whitney, Chi square or Fisher's exact tests as appropriate in addition to logistic regression analysis. P < 0.05 was considered statistically significant. Mini-PNL (378) and standard-PNL (151) were nearly comparable in patients and stones criteria including stone burden (3.77 ± 2.21 vs 3.77 ± 2.43 cm 2 ; respectively). There was no significant difference in number of tracts or supracostal puncture. Mini-PNL had longer operative time (68.6 ± 29.09 vs 60.49 ± 11.38 min; p = 0.434), significantly shorter hospital stay (2.43 ± 1.46 vs 4.29 ± 1.28 days) and significantly higher rate of tubeless PNL (75.1 vs 4.6%). Complications were significantly higher in standard-PNL (7.9 vs 20.5%; p < 0.001). SFR was significantly lower in Mini-PNL (89.9 vs 96%; p = 0.022). This significant difference was found with multiple stones and large stone burden (> 2 cm 2 ), but the SFR was comparable between both groups with single stone or stone burden ≤ 2 cm. Logistic regression analysis confirmed significantly higher complications and SFR with standard-PNL but with significantly shorter operative time. Mini-PNL has significantly lower SFR when compared to standard-PNL (but clinically comparable) with markedly reduced complications and hospital stay. Most of cases can be performed tubeless. The significant difference in SFR was found with multiple stones or large stone burden (> 2 cm 2 ), but not with single stones or stone burden ≤ 2 cm 2 .

  9. Comparison of Wiltse's paraspinal approach and open book laminectomy for thoracolumbar burst fractures with greenstick lamina fractures: a randomized controlled trial.

    PubMed

    Chen, Zhi-da; Wu, Jin; Yao, Xiao-Tao; Cai, Tao-Yi; Zeng, Wen-Rong; Lin, Bin

    2018-03-02

    Posterior short-segment pedicle screw fixation is used to treat thoracolumbar burst fractures. However, no randomized controlled studies have compared the efficacy of the two approaches--the Wiltse's paraspinal approach and open book laminectomy in the treatment of thoracolumbar burst fractures with greenstick lamina fractures. Patients with burst fractures of the thoracolumbar spine without neurological deficit were randomized to receive either the Wiltse's paraspinal approach (group A, 24 patients) or open book laminectomy (group B, 23 patients). Patients were followed postoperatively for average of 27.4 months. Clinical and radiographic data of the two approaches were collected and compared. Our results showed the anterior segmental height, kyphotic angle, visual analog scale (VAS) score, and Smiley-Webster Scale (SWS) score significantly improved postoperatively in both groups, indicating that both the Wiltse's paraspinal approach and open book laminectomy can effectively treat thoracolumbar burst fractures with greenstick lamina fractures. The Wiltse's paraspinal approach was found to have significantly shorter operating time, less blood loss, and shorter length of hospital stay compared to open book laminectomy. However, there were two (2/24) patients in group A that had neurological deficits postoperatively and required a second exploratory operation. Dural tears and/or cauda equina entrapment were subsequently found in four patients in group B and all two patients of neurological deficits in group A during operation. No screw loosening, plate breakage, or other internal fixation failures were found at final follow-up. The results demonstrated that either of the two surgical approaches can achieve satisfactory results in treating thoracolumbar burst fractures in patients with greenstick lamina fractures. However, if there is any clinical or radiographic suspicion of a dural tear and/or cauda equina entrapment pre-operation, patients should receive an open book laminectomy to avoid a second exploratory operation. More research is still needed to optimize clinical decision-making regarding surgical approach.

  10. Novel synthesis approach for stable sodium superoxide (NaO2) nanoparticles for LPG sensing application

    NASA Astrophysics Data System (ADS)

    Nemade, Kailash; Waghuley, Sandeep

    2017-05-01

    The synthesis of stable superoxide is still great challenge for the researchers working in the field of materials science. Through this letter, we report the novel and simple synthesis approach for the preparation of stable sodium superoxide (NaO2) nanoparticles. NaO2 nanoparticles were prepared by a spray pyrolysis technique, under oxygen rich environment for gas sensing application. The texture characterizations show that as-obtained NaO2 nanoparticles have high structural purity. Most importantly, NaO2 nanoparticles exhibits higher sensing response, shorter response time and recovery time, low operating temperature and good stability during sensing of liquefied petroleum gas (LPG). The main accomplishment of present work is that as-fabricated sensor has low operating temperature (423 K), which is below auto-ignition temperature of LPG. The gas sensing mechanism of NaO2 nanoparticles was discussed without the conventional oxygen bridging mechanism. Through this short communication, LPG sensing application of stable sodium superoxide nanoparticle is explored.

  11. Addressing case specific biogas plant tasks: industry oriented methane yields derived from 5L Automatic Methane Potential Test Systems in batch or semi-continuous tests using realistic inocula, substrate particle sizes and organic loading.

    PubMed

    Kolbl, Sabina; Paloczi, Attila; Panjan, Jože; Stres, Blaž

    2014-02-01

    The primary aim of the study was to develop and validate an in-house upscale of Automatic Methane Potential Test System II for studying real-time inocula and real-scale substrates in batch, codigestion and enzyme enhanced hydrolysis experiments, in addition to semi-continuous operation of the developed equipment and experiments testing inoculum functional quality. The successful upscale to 5L enabled comparison of different process configurations in shorter preparation times with acceptable accuracy and high-through put intended for industrial decision making. The adoption of the same scales, equipment and methodologies in batch and semi-continuous tests mirroring those at full scale biogas plants resulted in matching methane yields between the two laboratory tests and full-scale, confirming thus the increased decision making value of the approach for industrial operations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Photoselective vaporization of the prostate with GreenLight 120-W laser versus transurethral resection of the prostate for benign prostatic hyperplasia: a systematic review with meta-analysis of randomized controlled trials.

    PubMed

    Zang, Ya-Chen; Deng, Xin-Xi; Yang, Dong-Rong; Xue, Bo-Xin; Xu, Li-Jun; Liu, Xiao-Long; Zhou, Yi-Bin; Shan, Yu-Xi

    2016-02-01

    The aim of this study is to assess the overall efficacy and safety of photoselective vaporization of the prostate (PVP) with GreenLight 120-W laser versus transurethral resection of the prostate (TURP) for treating patients of benign prostate hyperplasia (BPH) with lower urinary tract symptoms (LUTS). We performed a literature search of The Cochrane Library and the electronic databases, including Embase, Medline, and Web of Science. Manual searches were conducted of the conference proceedings, including European Association of Urology and American Urological Association (2007 to 2012). Outcomes reviewed included clinical baseline characteristics, perioperative data, complications, and postoperative functional results, such as postvoid residual (PVR), international prostate symptom score (IPSS), quality of life (QoL), and maximum flow rate (Qmax). Six randomized controlled trials (RCTs) were enrolled. Three hundred and forty-seven patients undergone 120-W PVP, and 350 patients were treated with TURP in the RCTs. There were no significant differences for clinical characteristics in these trials. In perioperative data, catheterization time and length of hospital stay were shorter in the PVP group. However, the operation time was shorter in the TURP group. Capsular perforation, blood transfusion, clot retention, and macroscopic hematuria were markedly less likely in PVP-treated subjects. The other complications between PVP and TURP did not demonstrate a statistic difference. There were no significant differences in QoL, PVR, IPSS, and Qmax in the 1, 3, 6, 12, and 24 months of postoperative follow-up. There was no significant difference at postoperation follow-up of functional outcomes including IPSS, PVR, Qmax, and QoL between the TURP-treated subjects and PVP-treated subjects. Owing to a shorter catheterization time, reduced hospital duration and less complication, PVP could be used as an alternative and a promising minimal invasive surgical procedure for the treatment of BPH.

  13. Processing time of addition or withdrawal of single or combined balance-stabilizing haptic and visual information

    PubMed Central

    Honeine, Jean-Louis; Crisafulli, Oscar; Sozzi, Stefania

    2015-01-01

    We investigated the integration time of haptic and visual input and their interaction during stance stabilization. Eleven subjects performed four tandem-stance conditions (60 trials each). Vision, touch, and both vision and touch were added and withdrawn. Furthermore, vision was replaced with touch and vice versa. Body sway, tibialis anterior, and peroneus longus activity were measured. Following addition or withdrawal of vision or touch, an integration time period elapsed before the earliest changes in sway were observed. Thereafter, sway varied exponentially to a new steady-state while reweighting occurred. Latencies of sway changes on sensory addition ranged from 0.6 to 1.5 s across subjects, consistently longer for touch than vision, and were regularly preceded by changes in muscle activity. Addition of vision and touch simultaneously shortened the latencies with respect to vision or touch separately, suggesting cooperation between sensory modalities. Latencies following withdrawal of vision or touch or both simultaneously were shorter than following addition. When vision was replaced with touch or vice versa, adding one modality did not interfere with the effect of withdrawal of the other, suggesting that integration of withdrawal and addition were performed in parallel. The time course of the reweighting process to reach the new steady-state was also shorter on withdrawal than addition. The effects of different sensory inputs on posture stabilization illustrate the operation of a time-consuming, possibly supraspinal process that integrates and fuses modalities for accurate balance control. This study also shows the facilitatory interaction of visual and haptic inputs in integration and reweighting of stance-stabilizing inputs. PMID:26334013

  14. Cost Analysis of Spinal Versus General Anesthesia for Lumbar Diskectomy and Laminectomy Spine Surgery.

    PubMed

    Agarwal, Prateek; Pierce, John; Welch, William C

    2016-05-01

    Lumbar spine surgery can be performed using various anesthetic modalities, most notably general or spinal anesthesia. Because data comparing the cost of these anesthetic modalities in spine surgery are scarce, this study asks whether spinal anesthesia is less costly than general anesthesia. A total of 542 patients who underwent elective lumbar diskectomy or laminectomy spine surgery between 2007 and 2011 were retrospectively identified, with 364 having received spinal anesthesia and 178 having received general anesthesia. Mean direct operating cost, indirect cost (general support staff, insurance, taxes, floor space, facility, and administrative costs), and total cost were compared among patients who received general and spinal anesthesia. Linear multiple regression analysis was used to identify the effect of anesthesia type on cost and determine the factors underlying this effect, while controlling for patient and procedure characteristics. When controlling for patient and procedure characteristics, use of spinal anesthesia was associated with a 41.1% lower direct operating cost (-$3629 ± $343, P < 0.001), 36.6% lower indirect cost (-$1603 ± $168, P < 0.001), and 39.6% lower total cost (-$5232 ± $482, P < 0.001) compared with general anesthesia. Shorter hospital stay, shorter duration of anesthesia, shorter duration of operation, and lower estimated blood loss contributed to lower costs for spinal anesthesia, but other factors beyond these were also responsible for lower direct operating and total costs. When comparing the benefits of spinal and general anesthesia, spinal anesthesia is less costly when used in patients undergoing lumbar diskectomy and laminectomy spine surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Costs and benefits of different methods of esophagectomy for esophageal cancer.

    PubMed

    Yanasoot, Alongkorn; Yolsuriyanwong, Kamtorn; Ruangsin, Sakchai; Laohawiriyakamol, Supparerk; Sunpaweravong, Somkiat

    2017-01-01

    Background A minimally invasive approach to esophagectomy is being used increasingly, but concerns remain regarding the feasibility, safety, cost, and outcomes. We performed an analysis of the costs and benefits of minimally invasive, hybrid, and open esophagectomy approaches for esophageal cancer surgery. Methods The data of 83 consecutive patients who underwent a McKeown's esophagectomy at Prince of Songkla University Hospital between January 2008 and December 2014 were analyzed. Open esophagectomy was performed in 54 patients, minimally invasive esophagectomy in 13, and hybrid esophagectomy in 16. There were no differences in patient characteristics among the 3 groups Minimally invasive esophagectomy was undertaken via a thoracoscopic-laparoscopic approach, hybrid esophagectomy via a thoracoscopic-laparotomy approach, and open esophagectomy by a thoracotomy-laparotomy approach. Results Minimally invasive esophagectomy required a longer operative time than hybrid or open esophagectomy ( p = 0.02), but these patients reported less postoperative pain ( p = 0.01). There were no significant differences in blood loss, intensive care unit stay, hospital stay, or postoperative complications among the 3 groups. Minimally invasive esophagectomy incurred higher operative and surgical material costs than hybrid or open esophagectomy ( p = 0.01), but there were no significant differences in inpatient care and total hospital costs. Conclusion Minimally invasive esophagectomy resulted in the least postoperative pain but the greatest operative cost and longest operative time. Open esophagectomy was associated with the lowest operative cost and shortest operative time but the most postoperative pain. Hybrid esophagectomy had a shorter learning curve while sharing the advantages of minimally invasive esophagectomy.

  16. Randomised clinical trial: prucalopride, a colonic pro-motility agent, reduces the duration of post-operative ileus after elective gastrointestinal surgery.

    PubMed

    Gong, J; Xie, Z; Zhang, T; Gu, L; Yao, W; Guo, Z; Li, Y; Lu, N; Zhu, W; Li, N; Li, J

    2016-04-01

    Previous studies have shown that recovery of colonic transit is a major determinant of post-operative ileus and clinical recovery after gastrointestinal surgery. Prucalopride is a highly selective 5-hydroxytryptamine receptor-4 agonist with colonic pro-motility effects. To evaluate the effect and safety of prucalopride on post-operative ileus and surgical outcomes after elective gastrointestinal surgery. In this phase II randomised clinical trial, 110 patients undergoing elective gastrointestinal surgery were randomised to either oral prucalopride (2 mg/day) (n = 55) or placebo (n = 55). Intervention was started 24 h after surgery and stopped after defecation or maximally at 7 days. The primary outcome was time to defecation. Secondary outcomes included time to first passage of flatus, tolerance of solid food, nasogastric tube reinsertion, post-operative length of stay, hospital readmission, overall cost, time to walk independently, surgical complications and inflammatory parameters. Patients who received prucalopride had a shorter time to defecation (65.0 vs. 94.5 h, P = 0.001), passage of flatus (53.0 vs. 73.0 h, P < 0.001), and post-operative length of stay (7.0 vs. 8.0 days, P = 0.001) than controls. The number of patients with prolonged ileus (>5 days) (16.4% vs. 34.5%, P = 0.026) and the C-reactive protein level on post-operative day 5 (35.67 vs. 59.07 mg/L, P = 0.040) were lower in the prucalopride group. There was no significant difference in post-operative Clavien-Dindo grade III and IV complications (P = 0.606) between the groups. Prucalopride is a safe and effective treatment to reduce post-operative ileus and systemic inflammation without affecting post-operative complications in patients undergoing elective gastrointestinal surgery. ClinicalTrials.gov: NCT02004652. © 2016 John Wiley & Sons Ltd.

  17. 77 FR 67409 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-09

    ...), 7410A (Definitions), 7420A (Applicability), 7430A (Synchronization of Member Business Clocks), 7440A... days after the date of the filing, or such shorter time as the Commission may designate if consistent... the proposed rule change, or such shorter time as designated by the Commission. \\11\\ 15 U.S.C. 78s(b...

  18. A Comparison of Robotic Versus Laparoscopic Adrenalectomy in Patients With Primary Hyperaldosteronism.

    PubMed

    Colvin, Jennifer; Krishnamurthy, Vikram; Jin, Judy; Shin, Joyce; Siperstein, Allan; Berber, Eren

    2017-10-01

    Over the last decade, robotic approaches have been described for removing adrenal tumors. Although there are reports comparing robotic and laparoscopic techniques in general, there are limited data on outcomes in patients with primary hyperaldosteronism (PHA). The aim of this study is to compare the safety and efficacy of robotic adrenalectomy (RA) versus laparoscopic adrenalectomy (LA) for PHA. The records of 20 patients who underwent RA for PHA were compared with 16 patients who underwent LA between 2000 and 2014. Data were retrospectively reviewed from a prospectively maintained, IRB-approved adrenal database. Statistical analysis was performed using t test and the Fisher exact analysis. Continuous variables are reported as mean±SEM. Demographic and clinical parameters were similar between the groups. There were no conversions to open in either group. Estimated blood loss, length of stay, and complication rates were comparable. Operative time was shorter in the robotic versus laparoscopic group (130±8.94 vs. 159±11.1 min, P=0.0487). In follow-up, the improvement in patients' blood pressure after adrenalectomy, as assessed by the reduction in the number of antihypertensive medications, was similar between the 2 groups. However, 1 patient in the RA and 1 patient in the LA group were not cured, as determined by postoperative aldosterone:renin levels. The biochemical cure rate between the groups was similar (P=0.529). To our knowledge, this is the first study comparing robotic versus laparoscopic resection of PHA. Our results show that the robotic approach was similar to laparoscopic regarding safety and efficacy. Operative time was shorter with the robotic approach, which could be related to more efficient dissection with wristed instrumentation.

  19. Awake Craniotomy Anesthesia: A Comparison of the Monitored Anesthesia Care and Asleep-Awake-Asleep Techniques.

    PubMed

    Eseonu, Chikezie I; ReFaey, Karim; Garcia, Oscar; John, Amballur; Quiñones-Hinojosa, Alfredo; Tripathi, Punita

    2017-08-01

    Commonly used sedation techniques for an awake craniotomy include monitored anesthesia care (MAC), using an unprotected airway, and the asleep-awake-asleep (AAA) technique, using a partially or totally protected airway. We present a comparative analysis of the MAC and AAA techniques, evaluating anesthetic management, perioperative outcomes, and complications in a consecutive series of patients undergoing the removal of an eloquent brain lesion. Eighty-one patients underwent awake craniotomy for an intracranial lesion over a 9-year period performed by a single-surgeon and a team of anesthesiologists. Fifty patients were treated using the MAC technique, and 31 were treated using the AAA technique. A retrospective analysis evaluated anesthetic management, intraoperative complications, postoperative outcomes, pain management, and complications. The MAC and AAA groups had similar preoperative patient and tumor characteristics. Mean operative time was shorter in the MAC group (283.5 minutes vs. 313.3 minutes; P = 0.038). Hypertension was the most common intraoperative complication seen (8% in the MAC group vs. 9.7% in the AAA group; P = 0.794). Intraoperative seizure occurred at a rate of 4% in the MAC group and 3.2% in the AAA group (P = 0.858). Awake cases were converted to general anesthesia in no patients in the MAC group and in 1 patient (3.2%) in the AAA group (P = 0.201). No cases were aborted in either group. The mean hospital length of stay was 3.98 days in the MAC group and 3.84 days in the AAA group (P = 0.833). Both the MAC and AAA sedation techniques provide an efficacious and safe method for managing awake craniotomy cases and produce similar perioperative outcomes, with the MAC technique associated with shorter operative time. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Review of contemporary role of robotics in bariatric surgery

    PubMed Central

    Bindal, Vivek; Bhatia, Parveen; Dudeja, Usha; Kalhan, Sudhir; Khetan, Mukund; John, Suviraj; Wadhera, Sushant

    2015-01-01

    With the rise in a number of bariatric procedures, surgeons are facing more complex and technically demanding surgical situations. Robotic digital platforms potentially provide a solution to better address these challenges. This review examines the published literature on the outcomes and complications of bariatric surgery using a robotic platform. Use of robotics to perform adjustable gastric banding, sleeve gastrectomy, roux-en-y gastric bypass (RYGB), biliopancreatic diversion with duodenal switch and revisional bariatric procedures (RBP) is assessed. A search on PubMed was performed for the most relevant articles in robotic bariatric surgery. A total of 23 articles was selected and reviewed in this article. The review showed that the use of robotics led to similar or lower complication rate in bariatric surgery when compared with laparoscopy. Two studies found a significantly lower leak rate for robotic gastric bypass when compared to laparoscopic method. The learning curve for RYGB seems to be shorter for robotic technique. Three studies revealed a significantly shorter operative time, while four studies found a longer operative time for robotic technique of gastric bypass. As for the outcomes of RBP, one study found a lower complication rate in robotic arm versus laparoscopic and open arms. Most authors stated that the use of robotics provides superior visualisation, more degrees of freedom and better ergonomics. The application of robotics in bariatric surgery seems to be a safe and feasible option. Use of robotics may provide specific advantages in some situations, and overcome limitations of laparoscopic surgery. Large and well-designed randomised clinical trials with long follow-up are needed to further define the role of digital platforms in bariatric surgery. PMID:25598594

  1. Controlled feasibility trial comparing the use of 1470nm and 940nm diode laser for the treatment of hyperplastic inferior nasal turbinates

    NASA Astrophysics Data System (ADS)

    Sroka, Ronald; Havel, Miriam; Leunig, Andreas; Betz, Christian S.

    2012-02-01

    Introduction: So far various laser systems have been used for volume reduction of hyperplastic nasal turbinates. In case of endonasal application, fiber controlled diode lasers are preferred due to reasons of cost and practicability. The aim of this clinical study was to compare the coagulative tissue effects using either λ=1470nm vs. λ=940nm emitting lasers in treatment of hyperplastic inferior nasal turbinates in an intraindividual manner. Patients and methods: This prospective, randomized, double-blind, clinical feasibility trial included 20 patients suffering from hyperplastic inferior nasal turbinates. In each case, one nasal cavity was treated using 1470nm laser at 4- 5W, the other one with 940nm laser at 12W. Treatment was performed endoscopically controlled in non-contact mode. Clinical presentation and patients symptoms were documented preoperatively and on day 1, 3, 7, 14 and 21 postoperatively using rhinomanometry, standardized questionnaires including SNOT 20 GAV (German adapted version), and separate endoscopic examination respectively. Results: None of the patients showed infections, hemorrhages or other complications occurred intra- or postoperatively. The mean operation time was significantly shorter using the 1470nm diode laser as compared to the 940nm laser, thus lower energy was applied. There was a significant reduction of nasal obstruction on day 21 postoperatively compared to the preoperative condition on both sides regardless of the laser system used. Evaluation of the SNOT-Scores as assessed before and three weeks after surgery showed significant subjective improvements. Conclusion: Compared with standard application of 940nm diode laser, 1470nm diode laser application provides an equivalent tissue reduction in shorter operation time using less total energy and a comparable relief of nasal obstruction postoperatively.

  2. Laparoscopic common bile duct exploration with primary closure for management of choledocholithiasis: a retrospective analysis and comparison with conventional T-tube drainage.

    PubMed

    Zhang, Hong-Wei; Chen, Ya-Jin; Wu, Chang-Hao; Li, Wen-Da

    2014-02-01

    Laparoscopic common bile duct exploration (LCBDE) had become one of the main options for management of choledocholithiasis. This retrospective comparative study aimed to evaluate on the feasibility and advantages of primary closure versus conventional T-tube drainage of the common bile duct (CBD) after laparoscopic choledochotomy. In this retrospective analysis, 100 patients (47 men and 53 women) with choledocholithiasis who underwent primary closure of the CBD (without T-tube drainage) after LCBDE (Group A) were compared with 92 patients who underwent LCBDE with T-tube drainage (Group B). Both groups were evaluated with regard to biliary complications, hospital stay, and recurrence of stones. The mean operation time was 104.12 minutes for Group A and 108.92 minutes for Group B (P = 0.069). The hospital stay was significantly shorter in Group A than that in Group B (6.95 days and 12.05 days, respectively; P < 0.001). In Group A, bile leakage occurred in two patients on postoperative Day 2 and Day 3, respectively. In Group B, bile leakage noted in one patient after removal of the T-tube on Day 14 after operation (P = 1.000). With a median follow-up time of 40 months for both groups, stone recurrence was noted in two patients in Group A and three patients in Group B (P = 0.672). Primary closure of the CBD is safe and feasible in selected patients after laparoscopic choledochotomy. It results in shorter duration of hospital stay without the need for carrying/care of a T-tube in the postoperative period and similar stone recurrence as that of the conventional method.

  3. Efficacy of transversus abdominis plane block with liposomal bupivacaine during open abdominal wall reconstruction.

    PubMed

    Fayezizadeh, Mojtaba; Majumder, Arnab; Neupane, Ruel; Elliott, Heidi L; Novitsky, Yuri W

    2016-09-01

    Transversus abdominis plane block (TAPb) is an analgesic adjunct used for abdominal surgical procedures. Liposomal bupivacaine (LB) demonstrates prolonged analgesic effects, up to 72 hours. We evaluated the analgesic efficacy of TAPb using LB for patients undergoing open abdominal wall reconstruction (AWR). Fifty patients undergoing AWR with TAPb using LB (TAP-group) were compared with a matched historical cohort undergoing AWR without TAPb (control group). Outcome measures included postoperative utilization of morphine equivalents, numerical rating scale pain scores, time to oral narcotics, and length of stay (LOS). Cohorts were matched demographically. No complications were associated with TAPb or LB. TAP-group evidenced significantly reduced narcotic requirements on operative day (9.5 mg vs 16.5 mg, P = .004), postoperative day (POD) 1 (26.7 mg vs 39.5 mg, P = .01) and POD2 (29.6 mg vs 40.7 mg, P = .047) and pain scores on operative day (5.1 vs 7.0, P <.001), POD1 (4.2 vs 5.5, P = .002), and POD2 (3.9 vs 4.8, P = .04). In addition, TAP-group demonstrated significantly shorter time to oral narcotics (2.7 days vs 4.0 days, P <.001) and median LOS (5.2 days vs 6.8 days, P = .004). TAPb with LB demonstrated significant reductions in narcotic consumption and improved pain control. TAPb allowed for earlier discontinuation of intravenous narcotics and shorter LOS. Intraoperative TAPb with LB appears to be an effective adjunct for perioperative analgesia in patients undergoing open AWR. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Does Robotic Roux-en-Y Gastric Bypass Provide Outcome Advantages over Standard Laparoscopic Approaches?

    PubMed

    Rogula, Tomasz; Koprivanac, Marijan; Janik, Michał Robert; Petrosky, Jacob A; Nowacki, Amy S; Dombrowska, Agnieszka; Kroh, Matthew; Brethauer, Stacy; Aminian, Ali; Schauer, Philip

    2018-04-10

    The aim was to compare clinical outcomes of patients treated with totally robotic Roux-en-Y gastric bypass (TRRYGB) with those treated with the different laparoscopic Roux-en-Y gastric bypass (LRYGB) techniques. The clinical benefit of the robotic approach to bariatric surgery compared to the standard laparoscopic approach is unclear. There are no studies directly comparing outcomes of TRRYGB with different LRYGB techniques. Outcomes of 578 obese patients who underwent RYGB between 2011 and 2014 at an academic center were assessed. Multivariable analysis and propensity matching were used for comparing TRRYGB to different LRYGB techniques, including 21-mm EEA circular-stapled gastrojejunal anastomosis (GJA, LRYGB-21CS), linear-stapled GJA (LRYGB-LS), and hand-sewn GJA (LRYGB-HS). The TRRYGB technique required a longer mean operative time compared to the other groups, respectively 204 ± 46 vs. 139 ± 30 min (LRYGB-21CS), 206 ± 37 vs. 158 ± 30 min (LRYGB-LS), and 210 ± 36 vs. 167 ± 30 min (LRYGB-HS). TRRYGB experienced a lower stricture rate (2 vs. 17%, P = 0.003), shorter hospital stay (2.6 ± 1.2 vs. 4.3 ± 5.5 days, P = 0.008), and lower readmission rate (12 vs. 28%, P = 0.009). No significant differences in outcomes were observed when comparing RRYGB to LRYGB-LS or LRYGB-HS. TRRYGB increases operative time compared to all LRYGB techniques. TRRYGB was superior to LRYGB-21CS in terms of significantly shorter hospital stay, lower readmission rate, and less frequent GJA stricture formation. TRRYGB provides no clinical advantages over the LRYGB-LS and LRYGB-HS techniques.

  5. Novel use of an ultrasonic bone-cutting device for endoscopic-assisted craniosynostosis surgery.

    PubMed

    Chaichana, Kaisorn L; Jallo, George I; Dorafshar, Amir H; Ahn, Edward S

    2013-07-01

    Endoscopic-assisted craniosynostosis surgery is associated with less blood loss and shorter operative times as compared to open surgery. However, in infants who have low circulating blood volumes, the endoscopic approach is still associated with significant blood loss. A major source of blood loss is the bone that is cut during surgery. We discuss the novel use of an ultrasonic bone-cutting device for craniosynostosis surgery, which decreases bone bleeding. This device, which has primarily only been used for spine and skull base surgery, may help reduce blood loss in these infants. All patients with single suture craniosynostosis who were operated on with the use of an ultrasonic bone-cutting device were identified. The information retrospectively recorded from patient charts included patient age, suture involved, blood loss, operative times, complications, preoperative hemoglobin, postoperative hemoglobin, length of hospital stay, and follow-up times. Thirteen patients (12 males, 1 female) underwent surgery with an ultrasonic bone-cutting device during the reviewed period. The average age (±standard deviation) of the patients was 11.8 (±1.6) weeks. Four patients had metopic synostosis and nine patients had sagittal synostosis. The average surgery time was 84 (±13) min. The median (interquartile range) blood loss was 20 (10-70) cc. No patients required blood transfusions. Three patients had dural tears. We demonstrate the novel use of an ultrasonic bone-cutting device for endoscopic-assisted craniosynostosis surgery. This device limited blood loss while maintaining short operative times for infants with low circulating blood volumes.

  6. A polymorphism in a transporter of testosterone is a determinant of androgen independence in prostate cancer.

    PubMed

    Sharifi, Nima; Hamada, Akinobu; Sissung, Tristan; Danesi, Romano; Venzon, David; Baum, Caitlin; Gulley, James L; Price, Douglas K; Dahut, William L; Figg, William D

    2008-08-05

    To determine if patients with advanced prostate cancer carrying a polymorphism that codes for a more active testosterone transporter have less durable responses to androgen-deprivation therapy (ADT) than patients not carrying this polymorphism. We previously determined that a polymorphism in SLCO1B3 affects testosterone transport and that those men who have at least one wild-type T allele at the 334 T > G polymorphism in this gene have a shorter survival. We hypothesized that the T allele which increases testosterone transport would be associated with a shorter interval from ADT to androgen independence. We examined the association between this SLCO1B3 polymorphism and time from ADT to androgen independence, ADT to prostate-specific antigen (PSA) nadir and PSA nadir to androgen independence in 68 Caucasian patients with advanced prostate cancer who were treated with ADT with metastatic disease (D2) or biochemical failure with no metastatic disease (D0). When examined separately, patients in the individual stages tended to have a shorter time to androgen independence with the T allele in the D0 (P = 0.11) and D2 (P = 0.18) groups. Combining these groups and stratifying by stage yielded a statistically significant shorter time to androgen independence with the T allele (P = 0.048). A polymorphism in a transporter that increases testosterone import is associated with a shorter time to androgen independence in patients with prostate cancer who are treated with ADT.

  7. Simplified Approach Charts Improve Data Retrieval Performance

    PubMed Central

    Stewart, Michael; Laraway, Sean; Jordan, Kevin; Feary, Michael S.

    2016-01-01

    The effectiveness of different instrument approach charts to deliver minimum visibility and altitude information during airport equipment outages was investigated. Eighteen pilots flew simulated instrument approaches in three conditions: (a) normal operations using a standard approach chart (standard-normal), (b) equipment outage conditions using a standard approach chart (standard-outage), and (c) equipment outage conditions using a prototype decluttered approach chart (prototype-outage). Errors and retrieval times in identifying minimum altitudes and visibilities were measured. The standard-outage condition produced significantly more errors and longer retrieval times versus the standard-normal condition. The prototype-outage condition had significantly fewer errors and shorter retrieval times than did the standard-outage condition. The prototype-outage condition produced significantly fewer errors but similar retrieval times when compared with the standard-normal condition. Thus, changing the presentation of minima may reduce risk and increase safety in instrument approaches, specifically with airport equipment outages. PMID:28491009

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radhi, Hassan

    Developments in the design and manufacture of photovoltaic cells have recently been a growing concern in the UAE. At present, the embodied energy pay-back time (EPBT) is the criterion used for comparing the viability of such technology against other forms. However, the impact of PV technology on the thermal performance of buildings is not considered at the time of EPBT estimation. If additional energy savings gained over the PV system life are also included, the total EPBT could be shorter. This paper explores the variation of the total energy of building integrated photovoltaic systems (BiPV) as a wall cladding systemmore » applied to the UAE commercial sector and shows that the ratio between PV output and saving in energy due to PV panels is within the range of 1:3-1:4. The result indicates that for the southern and western facades in the UAE, the embodied energy pay-back time for photovoltaic system is within the range of 12-13 years. When reductions in operational energy are considered, the pay-back time is reduced to 3.0-3.2 years. This study comes to the conclusion that the reduction in operational energy due to PV panels represents an important factor in the estimation of EPBT. (author)« less

  9. Reduced Operating Time but Not Blood Loss With Cruciate Retaining Total Knee Arthroplasty

    PubMed Central

    Vermesan, Dinu; Trocan, Ilie; Prejbeanu, Radu; Poenaru, Dan V; Haragus, Horia; Gratian, Damian; Marrelli, Massimo; Inchingolo, Francesco; Caprio, Monica; Cagiano, Raffaele; Tatullo, Marco

    2015-01-01

    Background There is no consensus regarding the use of retaining or replacing cruciate implants for patients with limited deformity who undergo a total knee replacement. Scope of this paper is to evaluate whether a cruciate sparing total knee replacement could have a reduced operating time compared to a posterior stabilized implant. Methods For this purpose, we performed a randomized study on 50 subjects. All procedures were performed by a single surgeon in the same conditions to minimize bias and only knees with a less than 20 varus deviation and/or maximum 15° fixed flexion contracture were included. Results Surgery time was significantly shorter with the cruciate retaining implant (P = 0.0037). The mean duration for the Vanguard implant was 68.9 (14.7) and for the NexGen II Legacy was 80.2 (11.3). A higher range of motion, but no significant Knee Society Scores at 6 months follow-up, was used as controls. Conclusions In conclusion, both implants had the potential to assure great outcomes. However, if a decision has to be made, choosing a cruciate retaining procedure could significantly reduce the surgical time. When performed under tourniquet, this gain does not lead to reduced blood loss. PMID:25584102

  10. The Misgav Ladach method: a step forward in the operative technique of caesarean section.

    PubMed

    Poonam; Banerjee, B; Singh, S N; Raina, A

    2006-01-01

    Caesarean delivery remains the most common intraperitoneal surgical procedure in obstetric and gynaecologic practice. Since time immemorial there have been countless efforts to improve the technique of caesarean section. One such innovative breakthrough technique is the Misgav Ladach method of caesarean of section. The objective of this trial was to compare the intraoperative and short-term postoperative outcomes between the conventional and the Misgav-Ladach technique for caesarean section. The randomized prospective comparative study was carried out in the department of Obstetrics and Gynaecology, B.P Koirala Institute of Health Sciences, Dharan Nepal. Four hundred patients were randomized to either Misgav Ladach or the Conventional method of caesarean section. Only term pregnancies with singleton foetuses' were included whereas pregnancies with previous caesarean section were excluded from the study. The study period was from September 2001 to September 2004. There was not much difference in the demographic variables between the two groups. The age of the patients ranged between 18-40 years. The mean age of patients in Misgav Ladach and conventional group was 24.5 and 23.6 years respectively. Foetal distress was the commonest indication for caesarean section followed by non progress of labour. The mean incision to delivery interval, operating time and blood loss in the Misgav Ladach group was 1 minute 30 seconds, 16 minutes and 35 0ml as compared to 3 minutes, 28 minutes and 600 ml in the conventional group respectively. 3.5%of patients in the Misgav Ladach group showed febrile morbidity as compared to 7% in the conventional group. 19% from conventional group and only 4%from Misgav Ladach group required added analgesia. Almost equal number of patients (10-12) in each group experienced significant headache.).0.1%in the Misgav group and 5% in the Conventional group required post operative blood transfusion. Four patients from the conventional group had their wound gaped. The number of neonates requiring intensive care was sixteen (8% ) in the conventional group and 3 (1.5%) in the Misgav group.6.5% from conventional group and 2% from Misgav Ladach group required maternal intensive care admissions. Misgav-Ladach technique has been be associated with shorter operative time, quicker recovery, and lesser need for postoperative medications, when compared with traditional caesarean section. It has also been shown to be more cost-effective. A further advantage of the technique may be the shorter time taken for the delivery of the child.

  11. Results of telerobotic hand controller study using force information and rate control

    NASA Technical Reports Server (NTRS)

    Willshire, Kelli F.; Harrison, F. W.; Hogge, Edward F.; Williams, Robert L.; Soloway, Donald

    1992-01-01

    To increase quantified information about the effectiveness and subjective workload of force information relayed through manipulator input control devices, a space related task was performed by eight subjects with kinesthetic force feedback and/or local force accommodation through three different input control devices (i.e., hand controllers) operating in rate control mode. Task completion time, manipulator work, and subjective responses were measured. Results indicated a difference among the hand controllers. For the Honeywell six degree-of-freedom hand controller, the overall task completion times were shortest, the amount of work exerted was the least, and was the most preferred by test subjects. Neither force accommodation with or without reflection resulted in shorter task completion times or reduced work although those conditions were better than no force information for some aspects. Comparisons of results from previous studies are discussed.

  12. The impact of service-specific staffing, case scheduling, turnovers, and first-case starts on anesthesia group and operating room productivity: a tutorial using data from an Australian hospital.

    PubMed

    McIntosh, Catherine; Dexter, Franklin; Epstein, Richard H

    2006-12-01

    In this tutorial, we consider the impact of operating room (OR) management on anesthesia group and OR labor productivity and costs. Most of the tutorial focuses on the steps required for each facility to refine its OR allocations using its own data collected during patient care. Data from a hospital in Australia are used throughout to illustrate the methods. OR allocation is a two-stage process. During the initial tactical stage of allocating OR time, OR capacity ("block time") is adjusted. For operational decision-making on a shorter-term basis, the existing workload can be considered fixed. Staffing is matched to that workload based on maximizing the efficiency of use of OR time. Scheduling cases and making decisions on the day of surgery to increase OR efficiency are worthwhile interventions to increase anesthesia group productivity. However, by far, the most important step is the appropriate refinement of OR allocations (i.e., planning service-specific staffing) 2-3 mo before the day of surgery. Reducing surgical and/or turnover times and delays in first-case-of-the-day starts generally provides small reductions in OR labor costs. Results vary widely because they are highly sensitive both to the OR allocations (i.e., staffing) and to the appropriateness of those OR allocations.

  13. Mandibular reconstruction with the vascularized fibula flap: comparison of virtual planning surgery and conventional surgery.

    PubMed

    Wang, Y Y; Zhang, H Q; Fan, S; Zhang, D M; Huang, Z Q; Chen, W L; Ye, J T; Li, J S

    2016-11-01

    This study evaluated the accuracy of mandibular reconstruction and assessed clinical outcomes in both virtual planning and conventional surgery patients. ProPlan CMF surgical planning software was used preoperatively in the virtual planning group. In the virtual planning group, fibula flaps were harvested and osteotomized, and the mandibles were resected and reconstructed assisted by the prefabricated cutting guides and templates. The main outcome measures included the operative time, postoperative computed tomography (CT) scans, facial appearance, and occlusal function. The ischemia time and total operation time were shorter in the virtual planning group than in the conventional surgery group. High precision with the use of the cutting guides and templates was found for both the fibula and mandible, and a good fit was noted among the pre-bent plate, mandible, and fibula segments in the virtual planning group. Postoperative CT scans also showed excellent mandibular contours of the fibula flaps in accordance with virtual plans in the virtual planning group. This study demonstrated that virtual surgical planning was able to achieve more accurate mandibular reconstruction than conventional surgery. The use of prefabricated cutting guides and plates makes fibula flap moulding and placement easier, minimizes the operating time, and improves clinical outcomes. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. Evaluation of the efficacy of laparoscopic resection for the management of exogenous cesarean scar pregnancy.

    PubMed

    Wang, Guangwei; Liu, Xiaofei; Bi, Fangfang; Yin, Lili; Sa, Rina; Wang, Dandan; Yang, Qing

    2014-05-01

    To retrospectively analyze the clinical data of 71 patients with exogenous cesarean scar pregnancy (CSP) treated in our hospital in the past 2 years, to compare the outcomes of exogenous CSP treated with different methods, and to evaluate the safety and feasibility of laparoscopic resection of exogenous CSP. Comparative observational study. Tertiary medical centers. 71 women with exogenous cesarean scar pregnancy. Hysteroscopic resection of CSP, and laparoscopic resection of CSP. Operation time, intraoperative blood loss, postoperative drainage of the uterine cavity, postoperative days in hospital, time for β-human chorionic gonadotropin (β-hCG) to return to normal levels, absorption time of the mass. For the laparoscopic group, the time for serum β-hCG to return normal levels and the postoperative drainage of the uterine cavity were significantly lower than in the patients who had undergone hysteroscopic resection. We found no statistically significant difference in the intraoperative blood loss and postoperative days in hospital between the two groups, but the operation time was longer in laparoscopic group. Laparoscopic surgery for a cesarean scar pregnancy has the advantages of a high success rate, fewer complications, and a shorter time for β-hCG levels to normalize. This procedure is especially suitable for the treatment of exogenous CSP. Copyright © 2014. Published by Elsevier Inc.

  15. Low-noise AlInAsSb avalanche photodiode

    NASA Astrophysics Data System (ADS)

    Woodson, Madison E.; Ren, Min; Maddox, Scott J.; Chen, Yaojia; Bank, Scott R.; Campbell, Joe C.

    2016-02-01

    We report low-noise avalanche gain from photodiodes composed of a previously uncharacterized alloy, Al0.7In0.3As0.3Sb0.7, grown on GaSb. The bandgap energy and thus the cutoff wavelength are similar to silicon; however, since the bandgap of Al0.7In0.3As0.3Sb0.7 is direct, its absorption depth is 5 to 10 times shorter than indirect-bandgap silicon, potentially enabling significantly higher operating bandwidths. In addition, unlike other III-V avalanche photodiodes that operate in the visible or near infrared, the excess noise factor is comparable to or below that of silicon, with a k-value of approximately 0.015. Furthermore, the wide array of absorber regions compatible with GaSb substrates enable cutoff wavelengths ranging from 1 μm to 12 μm.

  16. Incidental De Garengeot's hernia: A case report of dual pathology to remember.

    PubMed

    Whitehead-Clarke, Thomas; Parampalli, Umesh; Bhardwaj, Rakesh

    2015-01-01

    A De Garengeot's hernia is the very rare dual pathology of a vermiform appendix within a femoral hernia. We discuss the rare case of a 62 year old female who presented as an emergency with a strangulated femoral hernia. Within the hernia sac a partly necrotic vermiform appendix was discovered. The patient successfully underwent an appendicectomy and repair of her femoral hernia. The post-operative period was uneventful, with no further issues at follow-up. Our case report displays the successful treatment of a De Garengeot's hernia as an emergency admission, with a shorter than average admission time, and no post-operative complications. This is a rare case of dual pathology, of which we believe there are few published cases. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Passive Q switching and mode-locking of Er:glass lasers using VO2 mirrors

    NASA Astrophysics Data System (ADS)

    Pollack, S. A.; Chang, D. B.; Chudnovky, F. A.; Khakhaev, I. A.

    1995-09-01

    Passive Q switching of an Er:glass laser with the pulse width varying between 14 and 80 ns has been demonstrated, using three resonator vanadium-dioxide-coated (VO2) mirror samples with temperature-dependent reflectivity and differing in the reflectivity contrast. The reflectivity changes because of a phase transition from a semiconductor to a metallic state. Broad band operating characteristics of VO2 mirrors provide Q switching over a wide range of wavelengths. In addition, mode-locked pulses with much shorter time scales have been observed, due to exciton formation and recombination. A simple criterion is derived for the allowable ambient temperatures at which the Q switching operates effectively. A simple relation has also been found relating the duration of the Q-switched pulse to the contrast in reflectivities of the two mirror phases.

  18. Prostate implant nomograms for the North American scientific {sup 103}Pd seed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Jay J.; Stevens, Ritchie N

    Palladium-103-({sup 103}Pd) seed has been increasingly used in prostate implantation as either definitive or boost therapy because of its shorter half-life and higher initial dose rate. Because a growing number of radiation oncologists prefer real-time implantation in the operating room, it will be helpful if the total activity of the seeds can be determined based on the gland size before the patient is taken to the operating room. Based on our clinic data, nomograms have therefore been developed for one of the widely used {sup 103}Pd seeds, the MED3633 seed, which is produced by North American Scientific, Inc. (NASI). Themore » total activities for implant volume ranging from 15 cc to 55 cc are provided for both seed 'monotherapy' and seed boost.« less

  19. 3D-printed guiding templates for improved osteosarcoma resection

    NASA Astrophysics Data System (ADS)

    Ma, Limin; Zhou, Ye; Zhu, Ye; Lin, Zefeng; Wang, Yingjun; Zhang, Yu; Xia, Hong; Mao, Chuanbin

    2016-03-01

    Osteosarcoma resection is challenging due to the variable location of tumors and their proximity with surrounding tissues. It also carries a high risk of postoperative complications. To overcome the challenge in precise osteosarcoma resection, computer-aided design (CAD) was used to design patient-specific guiding templates for osteosarcoma resection on the basis of the computer tomography (CT) scan and magnetic resonance imaging (MRI) of the osteosarcoma of human patients. Then 3D printing technique was used to fabricate the guiding templates. The guiding templates were used to guide the osteosarcoma surgery, leading to more precise resection of the tumorous bone and the implantation of the bone implants, less blood loss, shorter operation time and reduced radiation exposure during the operation. Follow-up studies show that the patients recovered well to reach a mean Musculoskeletal Tumor Society score of 27.125.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong Sun Lee; Yu Ryang Pyun

    A food drying process in a tunnel dryer was modeled from Keey's drying model and experimental drying curve, and optimized in operating conditions consisting of inlet air temperature, air recycle ratio and air flow rate. Radish was chosen as a typical food material to be dried, because it has the typical drying characteristics of food and quality indexes of ascorbic acid destruction and browning during drying. Optimization results of cocurrent and counter current tunnel drying showed higher inlet air temperature, lower recycle ratio and higher air flow rate with shorter total drying time. Compared with cocurrent operation counter current dryingmore » used lower air temperature, lower recycle ratio and lower air flow rate, and appeared to be more efficient in energy usage. Most of consumed energy was shown to be used for sir heating and then escaped from the dryer in the form of exhaust air.« less

  1. Transurethral Nd:YALO3 laser prostatectomy for prostatic hyperplasia--18 cases

    NASA Astrophysics Data System (ADS)

    Chen, Wen B.; Chen, Zi-Fu; Huang, Chao; Gao, Xiang-Xun; Lin, Sheng-Sheng; Zhan, Tian-qi; Shen, Hong Y.; Zeng, Rui R.; Zhou, Ye P.; Yu, Gui F.; Huang, Cheng H.; Zeng, Zhang D.

    1994-05-01

    18 cases of BHP were treated since 1990 by Nd:YALO3 (Nd:YAP) laser transurethral prostatectomy. The ages of these patients from 54 to 88 years with a mean age of 69.6 years. In all cases, there were dysuria, 10 cases acute retention of urine, 5 cases residual urine more than 50 ml, 12 cases abnormal ECG. 4 cases chronic bronchitis and pulmonary emphysema, 4 cases hypertension and 3 cases diabetic. The working conditions of the laser machine are as follows: wavelength of laser: 1079.5 nm; output power of fiber: variation range from 0 to 100 w. The merits of the procedure were less bleeding during operation, shorter operation time and more quick convascence. Cure has been achieved in 11 cases and improvement in 2 cases. The indication, merits and complication of TULP were discussed.

  2. Robotics in reproductive surgery: strengths and limitations.

    PubMed

    Catenacci, M; Flyckt, R L; Falcone, T

    2011-09-01

    Minimally invasive surgical techniques are becoming increasingly common in gynecologic surgery. However, traditional laparoscopy can be challenging. A robotic surgical system gives several advantages over traditional laparoscopy and has been incorporated into reproductive gynecological surgeries. The objective of this article is to review recent publications on robotically-assisted laparoscopy for reproductive surgery. Recent clinical research supports robotic surgery as resulting in less post-operative pain, shorter hospital stays, faster return to normal activities, and decreased blood loss. Reproductive outcomes appear similar to alternative approaches. Drawbacks of robotic surgery include longer operating room times, the need for specialized training, and increased cost. Larger prospective studies comparing robotic approaches with laparoscopy and conventional open surgery have been initiated and information regarding long-term outcomes after robotic surgery will be important in determining the ultimate utility of these procedures. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Anterolateral minithoracotomy versus median sternotomy for the treatment of congenital heart defects: a meta-analysis and systematic review

    PubMed Central

    2012-01-01

    Background Anterolateral Minithoracotomy (ALMT) for the radical correction of Congenital Heart Defects is an alternative to Median Sternotomy (MS) due to reduce operative trauma accelerating recovery and yield a better cosmetic outcome after surgery. Our purpose is to conduct whether ALMT would bring more short-term benefits to patients than conventional Median Sternotomy by using a meta-analysis of case–control study in the published English Journal. Methods 6 case control studies published in English from 1997 to 2011 were identified and synthesized to compare the short-term postoperative outcomes between ALMT and MS. These outcomes were cardiopulmonary bypass time, aortic cross-clamp time, intubation time, intensive care unit stay time, and postoperative hospital stay time. Results ALMT had significantly longer cardiopulmonary bypass times (8.00 min more, 95% CI 0.36 to 15.64 min, p = 0.04). Some evidence proved that aortic cross-clamp time of ALMT was longer, yet not significantly (2.38 min more, 95% CI −0.15 to 4.91 min, p = 0.06). In addition, ALMT had significantly shorter intubation time (1.66 hrs less, 95% CI −3.05 to −0.27 hrs, p = 0.02). Postoperative hospital stay time was significantly shorter with ALMT (1.52 days less, 95% CI −2.71 to −0.33 days, p = 0.01). Some evidence suggested a reduction in ICU stay time in the ALMT group. However, this did not prove to be statistically significant (0.88 days less, 95% CI −0.81 to 0.04 days, p = 0.08). Conclusion ALMT can bring more benefits to patients with Congenital Heart Defects by reducing intubation time and postoperative hospital stay time, though ALMT has longer CPB time and aortic cross-clamp time. PMID:22559820

  4. Robot-assisted total mesorectal excision for rectal cancer: case-matched comparison of short-term surgical and functional outcomes between the da Vinci Xi and Si.

    PubMed

    Morelli, Luca; Di Franco, Gregorio; Guadagni, Simone; Rossi, Leonardo; Palmeri, Matteo; Furbetta, Niccolò; Gianardi, Desirée; Bianchini, Matteo; Caprili, Giovanni; D'Isidoro, Cristiano; Mosca, Franco; Moglia, Andrea; Cuschieri, Alfred

    2018-02-01

    Robotic rectal resection with da Vinci Si has some technical limitations, which could be overcome by the new da Vinci Xi. We compare short-term surgical and functional outcomes following robotic rectal resection with total mesorectal excision for cancer, with the da Vinci Xi (Xi-RobTME group) and the da Vinci Si (Si-RobTME group). The first consecutive 30 Xi-RobTME were compared with a Si-RobTME control group of 30 patients, selected using a one-to-one case-matched methodology from our prospectively collected Institutional database, comprising all cases performed between April 2010 and September 2016 by a single surgeon. Perioperative outcomes were compared. The impact of minimally invasive TME on autonomic function and quality of life was analyzed with specific questionnaires. The docking and overall operative time were shorter in the Xi-RobTME group (p < 0.001 and p < 0.05 respectively). The mean differences of overall operative time and docking time were -33.8 min (95% CI -5.1 to -64.5) and -6 min (95% CI -4.1 to -7.9), respectively. A fully-robotic approach with complete splenic flexure mobilization was used in 30/30 (100%) of the Xi-RobTME cases and in 7/30 (23%) of the Si-RobTME group (p < 0.001). The hybrid approach in males and patients with BMI > 25 kg/m 2 was necessary in ten patients (45 vs. 0%, p < 0.001) and in six patients (37 vs. 0%, p < 0.05), in the Si-RobTME and Xi-RobTME groups, respectively. There were no differences in conversion rate, mean hospital stay, pathological data, and in functional outcomes between the two groups before and at 1 year after surgery. The technical advantages offered by the da Vinci Xi seem to be mainly associated with a shorter docking and operative time and with superior ability to perform a fully-robotic approach. Clinical and functional outcomes seem not to be improved, with the introduction of the new Xi platform.

  5. Loop ileostomy closure: comparison of cost effectiveness between suture and stapler.

    PubMed

    Horisberger, Karoline; Beldi, Guido; Candinas, Daniel

    2010-12-01

    Closure of loop ileostomy can be safely performed using sutures or staplers. The aim of the present study was to compare the cost effectiveness of three different techniques. A total of 128 consecutive patients who underwent closure of loop ileostomy between January 2002 and December 2008 were analyzed retrospectively. The primary outcome parameter was operative cost. Closure of ileostomy was performed in 66 patients with hand-sewn anastomosis, in 25 patients with stapler only, and in 37 patients with a combination of stapler and suture. There were no differences in terms of early and late postoperative complications. Operative time was significantly longer for "suture only" (101.4 ± 26 min) than for "stapler/suture" (-4.9 min) and "stapler only" (-17.8 min); the difference between the three groups is significant (p = 0.05). Duration of hospital stay was not different among the three groups. Operative costs with "stapler/suture" (1,755.9 ± 355.6 EUR) were significantly higher than with "suture only" (-254 EUR; p = 0.001) and "stapler only" (-236 EUR; p = 0.005). Operative time using the stapler only is significantly shorter than with hand-sewn anastomosis or combinations of stapler and suture. Operative costs are significantly higher for a procedure that includes suture and stapler.

  6. Comparison of Piezosurgery and Hammer-Chisel in Endoscopic Dacryocystorhinostomy.

    PubMed

    Çukurova, Ibrahim; Bulğurcu, Suphi; Arslan, Ilker Burak; Dikilitaş, Bünyamin

    2018-05-08

    In this study, we compared the advantages and disadvantages of piezosurgery and hammer-chisel used in endoscopic dacryocystorhinostomy (EDCR). Between January 2012 and January 2016, 10 women and 8 men in whom piezosurgery was used (group 1) and 11 women and 7 men in whom hammer-chisel was used (group 2) during EDCR operations were compared retrospectively. Recurrence, operation time, postoperative bleeding, and operative cost were evaluated in patients who were followed for an average of 11.8 months. In addition, visual analogue scale (VAS) was used to assess pain at 6 hours postoperatively. No recurrence was observed in group 1, but recurrence was observed in 2 patients in group 2 (P = 0.685). There was no postoperative bleeding in both groups. The mean duration of operation was 30.6 ± 8.2 minutes in group 1 and 46.8 ± 9.5 minutes in group 2 (P = 0.038). The VAS score in group 1 was 2.7 ± 1.4 and the VAS score in group 2 was 5.8 ± 2.2 (P = 0.01). Piezosurgery costs an additional $325 for each patient while the use of the hammer-chisel does not incur additional costs. Piezosurgery causes shorter operation time, less recurrence, and less pain when compared with hammer-chisel.

  7. The Effects of Pre-Operative Enteral Nutrition from Nasal Feeding Tubes on Gastric Outlet Obstruction.

    PubMed

    Chen, Zhi-Hua; Lin, Su-Yong; Dai, Qi-Bao; Hua, Jin; Chen, Shao-Qin

    2017-04-10

    We examined gastric outlet obstruction (GOO) patients who received two weeks of strengthening pre-operative enteral nutrition therapy (pre-EN) through a nasal-jejenal feeding tube placed under a gastroscope to evaluate the feasibility and potential benefit of pre-EN compared to parenteral nutrition (PN). In this study, 68 patients confirmed to have GOO with upper-gastrointestinal contrast and who accepted the operation were randomized into an EN group and a PN group. The differences in nutritional status, immune function, post-operative complications, weight of patients, first bowel sound and first flatus time, pull tube time, length of hospital stay (LOH), and cost of hospitalization between pre-operation and post-operation were all recorded. Statistical analyses were performed using the chi square test and t -test; statistical significance was defined as p < 0.05. The success rate of the placement was 91.18% (three out of 31 cases). After pre-EN, the levels of weight, albumin (ALB), prealbumin (PA), and transferrin (TNF) in the EN group were significantly increased by pre-operation day compared to admission day, but were not significantly increased in the PN group; the weights in the EN group were significantly increased compared to the PN group by pre-operation day and day of discharge; total protein (TP), ALB, PA, and TNF of the EN group were significantly increased compared to the PN group on pre-operation and post-operative days one and three. The levels of CD3+, CD4+/CD8+, IgA, and IgM in the EN group were higher than those of the PN group at pre-operation and post-operation; the EN group had a significantly lower incidence of poor wound healing, peritoneal cavity infection, pneumonia, and a shorter first bowel sound time, first flatus time, and post-operation hospital stay than the PN group. Pre-EN through a nasal-jejunum feeding tube and placed under a gastroscope in GOO patients was safe, feasible, and beneficial to the nutrition status, immune function, and gastrointestinal function, and sped up recovery, while not increasing the cost of hospitalization.

  8. Fire Engine Support and On-scene Time in Prehospital Stroke Care - A Prospective Observational Study.

    PubMed

    Puolakka, Tuukka; Väyrynen, Taneli; Erkkilä, Elja-Pekka; Kuisma, Markku

    2016-06-01

    Introduction On-scene time (OST) previously has been shown to be a significant component of Emergency Medical Services' (EMS') operational delay in acute stroke. Since stroke patients are managed routinely by two-person ambulance crews, increasing the number of personnel available on the scene is a possible method to improve their performance. Hypothesis Using fire engine crews to support ambulances on the scene in acute stroke is hypothesized to be associated with a shorter OST. All patients transported to hospital as thrombolysis candidates during a one-year study period were registered by the ambulance crews using a case report form that included patient characteristics and operational EMS data. Seventy-seven patients (41 [53%] male; mean age of 68.9 years [SD=15]; mean Glasgow Coma Score [GCS] of 15 points [IQR=14-15]) were eligible for the study. Forty-five cases were managed by ambulance and fire engine crews together and 32 by the ambulance crews alone. The median ambulance response time was seven minutes (IQR=5-10) and the fire engine response time was six minutes (IQR=5-8). The number of EMS personnel on the scene was six (IQR=5-7) and two (IQR=2-2), and the OST was 21 minutes (IQR=18-26) and 24 minutes (IQR=20-32; P =.073) for the groups, respectively. In a following regression analysis, using stroke as the dispatch code was the only variable associated with short (<22 minutes) OST with an odds ratio of 3.952 (95% CI, 1.279-12.207). Dispatching fire engine crews to support ambulances in acute stroke care was not associated with a shorter on-scene stay when compared to standard management by two-person ambulance crews alone. Using stroke as the dispatch code was the only variable that was associated independently with a short OST. Puolakka T , Väyrynen T , Erkkilä E-P , Kuisma M . Fire engine support and on-scene time in prehospital stroke care - a prospective observational study. Prehosp Disaster Med. 2016;31(3):278-281.

  9. Magnetic navigation system assisted percutaneous coronary intervention: a comparison to the conventional approach in daily practice.

    PubMed

    Li, Chun-Jian; Wang, Hui; Yang, Zhi-Jian; Cao, Ke-Jiang

    2011-01-01

    The benefits of the magnetic navigation system (MNS) for percutaneous coronary intervention (PCI) remain unclear, and a comparison of the MNS assisted approach to the conventional approach for PCI, when used in daily practice, is little studied. This study aimed to investigate the benefits of an MNS assisted technique as compared to the conventional technique for PCI. Forty-eight consecutive patients scheduled for PCI were recruited between December 2009 and April 2010. MNS assisted PCIs were performed on 54 target vessels. Another 45 patients with 54 target vessels undergoing conventional PCIs were selected from a historical population of patients to match the MNS group according to the coronary lesion type (ACC/AHA classification). Emergency PCIs and chronic total occlusions were excluded from both groups. Analyses were performed using Stata 9.2 statistical software. There were no significant differences between the baseline characteristics of the MNS group and the control group. The success rates were 100.0% for the MNS assisted PCI and 98.1% for the conventional PCI, which did not reach a significant difference (P = 1.000); there were also no significant differences in terms of guide wire crossing time ((51.7 ± 30.5) seconds vs. (57.5 ± 49.4) seconds, P = 0.448), operation time ((28.4 ± 15.9) minutes vs. (28.0 ± 24.7) minutes, P = 0.935), X-ray exposure ((458.1 ± 350.1) µGym(2) vs. (558.7 ± 451.7) µGym(2), P = 0.197; and (94.2 ± 80.9) mGy vs. (96.2 ± 77.3) mGy, P = 0.895) or contrast usage ((7.3 ± 4.0) ml vs. (6.1 ± 3.7) ml, P = 0.121) between the two groups. However, a trend toward shorter guide wire crossing time and less X-ray exposure were observed for the magnetic group. In daily practice, MNS assisted PCI resulted in a similar procedural success rate, operation time, and contrast usage, with a trend toward shorter guide wire crossing time and less X-ray exposure when compared to the conventional PCI.

  10. Temperature analysis during bonding of brackets using LED or halogen light base units.

    PubMed

    Silva, Paulo César Gomes; De Fátima Zanirato Lizarelli, Rosane; Moriyama, Lílian Tan; De Toledo Porto Neto, Sizenando; Bagnato, Vanderlei Salvador

    2005-02-01

    The purpose of our investigation is to compare the intrapulpal temperature changes following blue LED system and halogen lamp irradiation at the enamel surface of permanent teeth. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Several light sources can be used: halogens, arc plasma, lasers, and recently blue LED systems. An important aspect to be observed during such a procedures is the temperature change. In this study, we have used nine human extracted permanent teeth: three central incisors, three lateral incisors, and three canines. Teeth were exposed to two light sources: blue LED system (preliminary commercial model LEC 470-II) and halogen lamp (conventional photo-cure equipment). The surface of teeth was exposed for 20, 40, and 60 sec at the buccal and lingual enamel surface with an angle of 45 degrees. Temperature values measured by a thermistor placed at pulpar chamber were read in time intervals of 1 sec. We obtained plots showing the temperature evolution as a function of time for each experiment. There is a correlation between heating quantity and exposition time of light source: with increasing exposition time, heating increases into the pulpal chamber. The halogen lamp showed higher heating than the LED system, which showed a shorter time of cooling than halogen lamp. The blue LED system seems like the indicated light source for photo-cure of composite resin during the bonding of brackets. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Blue LED equipment did not heat during its use. This could permit a shorter clinical time of operation and better performance.

  11. Conventional versus traction-assisted endoscopic submucosal dissection for gastric neoplasms: a multicenter, randomized controlled trial (with video).

    PubMed

    Yoshida, Masao; Takizawa, Kohei; Suzuki, Sho; Koike, Yoshiki; Nonaka, Satoru; Yamasaki, Yasushi; Minagawa, Takeyoshi; Sato, Chiko; Takeuchi, Chihiro; Watanabe, Ko; Kanzaki, Hiromitsu; Morimoto, Hiroyuki; Yano, Takafumi; Sudo, Kosuke; Mori, Keita; Gotoda, Takuji; Ono, Hiroyuki

    2018-05-01

    The aim of this study was to clarify whether dental floss clip (DFC) traction improves the technical outcomes of endoscopic submucosal dissection (ESD). A superiority, randomized control trial was conducted at 14 institutions across Japan. Patients with single gastric neoplasm meeting the indications of the Japanese guidelines for gastric treatment were enrolled and assigned to receive conventional ESD or DFC traction-assisted ESD (DFC-ESD). Randomization was performed according to a computer-generated random sequence with stratification by institution, tumor location, tumor size, and operator experience. The primary endpoint was ESD procedure time, defined as the time from the start of the submucosal injection to the end of the tumor removal procedure. Between July 2015 and September 2016, 640 patients underwent randomization. Of these, 316 patients who underwent conventional ESD and 319 patients who underwent DFC-ESD were included in our analysis. The mean ESD procedure time was 60.7 and 58.1 minutes for conventional ESD and DFC-ESD, respectively (P = .45). Perforation was less frequent in the DFC-ESD group (2.2% vs .3%, P = .04). For lesions located in the greater curvature of the upper or middle stomach, the mean procedure time was significantly shorter in the DFC-ESD group (104.1 vs 57.2 minutes, P = .01). Our findings suggest that DFC-ESD does not result in shorter procedure time in the overall patient population, but it can reduce the risk of perforation. When selectively applied to lesions located in the greater curvature of the upper or middle stomach, DFC-ESD provides a remarkable reduction in procedure time. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  12. A Comparison of Outcomes Following Laparoscopic and Open Hysterectomy With or Without Lymphadenectomy for Presumed Early-Stage Endometrial Cancer: Results From the Medical Research Council ASTEC Trial.

    PubMed

    Kyrgiou, Maria; Swart, Anne-Marie; Qian, Wendi; Warwick, Jane

    2015-10-01

    Laparoscopic hysterectomy (LH) is increasingly used for the management of endometrial malignancy. Its benefits may be particularly pronounced as these women are more likely to be older or obese. The aim of this study was to determine whether outcomes for LH are comparable to the open hysterectomy (OH). This was a prospective cohort study nested within the multicenter ASTEC (A Study in the Treatment of Endometrial Cancer) randomized controlled trial (1998-2005). Women with presumed early endometrial cancer were included. Laparoscopic hysterectomy was compared with OH with or without systematic lymphadenectomy. Overall survival, time to first recurrence, complication rates, and surgical outcomes were the main outcome measures. Of 1408 women, 1309 (93%) received OH, and 99 (7%) had LH. LH was associated with longer operating time (median, LH 105 minutes [interquartile range (IQR), 60-150] vs OH 80 minutes [IQR, 60-95]; P < 0.001) but 50% shorter hospital stay (median, LH 4 days [IQR, 3-5] vs OH 6 days [IQR, 5-7]). The number of harvested lymph nodes was similar (median, LH 13 [IQR, 10-16] vs OH 12 [IQR, 11-13]; P = 0.67). LH had fewer intraoperative and postoperative adverse events (9% difference, LH 21% vs OH 30%; borderline significance; P = 0.07). The rate of conversion to laparotomy for the LH group was high (27%). The median follow-up was 37 months. After adjusting for significant prognostic factors, the hazard ratio for overall survival in those who underwent LH compared with those who underwent OH was 0.67 (95% confidence interval, 0.31-1.43) (P = 0.30). Laparoscopic hysterectomy for early endometrial cancer is safe. Although it requires longer operating time it is associated with shorter hospital stay and favorable morbidity profile. Further studies are required to assess the long-term safety.

  13. MID-VASTUS VS MEDIAL PARA-PATELLAR APPROACH IN TOTAL KNEE REPLACEMENT—TIME TO DISCHARGE

    PubMed Central

    Mukherjee, P.; Press, J.; Hockings, M.

    2009-01-01

    Background It has been shown before that when compared with the medial para-patellar approach, the mid-vastus approach for TKR results in less post-operative pain for patients and more rapid recovery of straight leg raise. As far as we are aware the post-operative length of stay of the two groups of patients has not been compared. We postulated that the reduced pain and more rapid recovery of straight leg raise would translate into an earlier, safe, discharge home for the mid-vastus patients compared with those who underwent a traditional medial para-patellar approach. Methods Twenty patients operated on by each of five established knee arthroplasty surgeons were evaluated prospectively with regard to their pre and post-operative range of movement, time to achieve straight leg raise post-operatively and length of post-operative hospital stay. Only one of the surgeons performed the mid-vastus approach, and the measurements were recorded by physiotherapists who were blinded as to the approach used on each patient. Results The results were analysed using a standard statistical software package, and although the mean length of stay was lower for the mid-vastus patients, the difference did not reach a level of significance (p = 0.13). The time taken to achieve straight leg raise post-operatively was significantly less in the mid-vastus group (p<0.001). Conclusion Although this study confirms previous findings that the mid-vastus approach reduces the time taken for patients to achieve straight leg raise, when compared with the medial para-patellar approach, on its own it does not translate into a significantly shorter length of hospital stay. In order to reduce the length of post-operative hospital stay with an accelerated rehabilitation program for TKR, a multi-disciplinary approach is required. Patient expectations, GP support, physiotherapists and nursing staff all have a role to play and the mid-vastus approach, in permitting earlier straight leg raising, significantly contributes to this. PMID:19742080

  14. Simultaneous bilateral stereotactic procedure for deep brain stimulation implants: a significant step for reducing operation time.

    PubMed

    Fonoff, Erich Talamoni; Azevedo, Angelo; Angelos, Jairo Silva Dos; Martinez, Raquel Chacon Ruiz; Navarro, Jessie; Reis, Paul Rodrigo; Sepulveda, Miguel Ernesto San Martin; Cury, Rubens Gisbert; Ghilardi, Maria Gabriela Dos Santos; Teixeira, Manoel Jacobsen; Lopez, William Omar Contreras

    2016-07-01

    OBJECT Currently, bilateral procedures involve 2 sequential implants in each of the hemispheres. The present report demonstrates the feasibility of simultaneous bilateral procedures during the implantation of deep brain stimulation (DBS) leads. METHODS Fifty-seven patients with movement disorders underwent bilateral DBS implantation in the same study period. The authors compared the time required for the surgical implantation of deep brain electrodes in 2 randomly assigned groups. One group of 28 patients underwent traditional sequential electrode implantation, and the other 29 patients underwent simultaneous bilateral implantation. Clinical outcomes of the patients with Parkinson's disease (PD) who had undergone DBS implantation of the subthalamic nucleus using either of the 2 techniques were compared. RESULTS Overall, a reduction of 38.51% in total operating time for the simultaneous bilateral group (136.4 ± 20.93 minutes) as compared with that for the traditional consecutive approach (220.3 ± 27.58 minutes) was observed. Regarding clinical outcomes in the PD patients who underwent subthalamic nucleus DBS implantation, comparing the preoperative off-medication condition with the off-medication/on-stimulation condition 1 year after the surgery in both procedure groups, there was a mean 47.8% ± 9.5% improvement in the Unified Parkinson's Disease Rating Scale Part III (UPDRS-III) score in the simultaneous group, while the sequential group experienced 47.5% ± 15.8% improvement (p = 0.96). Moreover, a marked reduction in the levodopa-equivalent dose from preoperatively to postoperatively was similar in these 2 groups. The simultaneous bilateral procedure presented major advantages over the traditional sequential approach, with a shorter total operating time. CONCLUSIONS A simultaneous stereotactic approach significantly reduces the operation time in bilateral DBS procedures, resulting in decreased microrecording time, contributing to the optimization of functional stereotactic procedures.

  15. Stapled haemorrhoidectomy in the operative treatment of grade III and IV haemorrhoids.

    PubMed

    Shrestha, S; Pradhan, G B N; Shrestha, R; Poudel, P; Bhattachan, C L

    2014-09-01

    Stapled haemorrhoidectomy (SH) is a minimally invasive intervention that uses a stapling device which avoids the need for wounds in the sensitive anal area and reduces the pain after surgery. This study was undertaken in Nepal Medical College Teaching Hospital from January 2010 to December 2012 to evaluate the efficacy of this modality of treatment among patients (32) who presented in the Surgery OPD with grade III and grade IV haemorrhoids. The results of SH were evaluated by the relief of symptoms, severity of post operative pain, and complications of SH. Twenty five (78.1%) patients had grade III and 7 (21.9%) presented with grade IV hemorrhoids. The most frequent presentation reported in our study was bleeding per rectum with perianal prolapse. Mean operating time was 40-60 minutes whereas mean hospital stay was 1.9 days. Urinary retention was the most common complication found in 12 (37.5%) patients in the immediate post operative period. SH is a safe, rapid, and convenient surgical remedy for grade III and grade IV hemorrhoids with low rate of complications, minimal postoperative pain, and shorter hospital stay.

  16. Effect of a Standardized Protocol of Antibiotic Therapy on Surgical Site Infection after Laparoscopic Surgery for Complicated Appendicitis.

    PubMed

    Park, Hyoung-Chul; Kim, Min Jeong; Lee, Bong Hwa

    Although it is accepted that complicated appendicitis requires antibiotic therapy to prevent post-operative surgical infections, consensus protocols on the duration and regimens of treatment are not well established. This study aimed to compare the outcome of post-operative infectious complications in patients receiving old non-standardized and new standard antibiotic protocols, involving either 5 or 10 days of treatment, respectively. We enrolled 1,343 patients who underwent laparoscopic surgery for complicated appendicitis between January 2009 and December 2014. At the beginning of the new protocol, the patients were divided into two groups; 10 days of various antibiotic regimens (between January 2009 and June 2012, called the non-standardized protocol; n = 730) and five days of cefuroxime and metronidazole regimen (between July 2012 and December 2014; standardized protocol; n = 613). We compared the clinical outcomes, including surgical site infection (SSI) (superficial and deep organ/space infections) in the two groups. The standardized protocol group had a slightly shorter operative time (67 vs. 69 min), a shorter hospital stay (5 vs. 5.4 d), and lower medical cost (US$1,564 vs. US$1,654). Otherwise, there was no difference between the groups. No differences were found in the non-standardized and standard protocol groups with regard to the rate of superficial infection (10.3% vs. 12.7%; p = 0.488) or deep organ/space infection (2.3% vs. 2.1%; p = 0.797). In patients undergoing laparoscopic surgery for complicated appendicitis, five days of cefuroxime and metronidazole did not lead to more SSIs, and it decreased the medical costs compared with non-standardized antibiotic regimens.

  17. Randomized controlled trial of moderate hypothermia versus deep hypothermia anesthesia on brain injury during Stanford A aortic dissection surgery.

    PubMed

    Sun, Xufang; Yang, Hua; Li, Xinyu; Wang, Yue; Zhang, Chuncheng; Song, Zhimin; Pan, Zhenxiang

    2018-01-01

    This study aimed to compare the effects of moderate versus deep hypothermia anesthesia for Stanford A aortic dissection surgery on brain injury. A total of 82 patients who would undergo Stanford A aortic dissection surgery were randomized into two groups: moderate hypothermia group (MH, n = 40, nasopharyngeal temperature 25 °C, and rectal temperature 28 °C) and deep hypothermia group (DH, n = 42, nasopharyngeal temperature 20 °C, and rectal temperature 25 °C). Different vascular replacement techniques including aortic root replacement, Bentall, and Wheat were used. The intraoperative and postoperative indicators of these patients were recorded. There were no differences in intraoperative and postoperative measures between MH and DH groups. The concentrations of neuron-specific enolase and S-100β increased with operation time, and were significantly lower in MH group than those in the DH group (P < 0.05). The occurrence rates of complications including chenosis, postoperative agitation, and neurological complications in MH group were significantly lower than in DH group. The recovery time, postoperative tube, and ICU intubation stay were significantly shorter in MH group than those in DH group (P < 0.05). There were no significant differences revealed in hospital stay and death rate. MH exhibited better cerebral protective effects, less complications, and shorter tube time than DH in surgery for Stanford A aortic dissection.

  18. Comparative study of upper lip frenectomy with the CO2 laser versus the Er, Cr: YSGG laser

    PubMed Central

    Pié-Sánchez, Jordi; España-Tost, Antonio J.; Arnabat-Domínguez, Josep

    2012-01-01

    Objectives: To compare upper lip frenulum reinsertion, bleeding, surgical time and surgical wound healing in frenectomies performed with the CO2 laser versus the Er, Cr:YSGG laser. Study design: A prospective study was carried out on 50 randomized pediatric patients who underwent rhomboidal resection of the upper lip frenulum with either the CO2 laser or the Er,Cr:YSGG laser. Twenty-five patients were assigned to each laser system. All patients were examined at 7, 14, 21 days and 4 months after the operation in order to assess the surgical wound healing. Results: Insertion of the frenulum, which was preoperatively located between the upper central incisors, migrated to the mucogingival junction as a result of using both laser systems in all patients. Only two patients required a single dose of 650 mg of paracetamol, one of either study group. CO2 laser registered improved intraoperative bleeding control results and shorter surgical times. On the other hand, the Er,Cr:YSGG laser achieved faster healing. Conclusions: Upper lip laser frenectomy is a simple technique that results in minimum or no postoperative swelling or pain, and which involves upper lip frenulum reinsertion at the mucogingival junction. The CO2 laser offers a bloodless field and shorter surgical times compared with the Er,Cr:YSGG laser. On the other hand, the Er,Cr:YSGG laser achieved faster wound healing. Key words:Frenectomy, upper lip frenulum, CO2 laser, Er,Cr:YSGG laser, laser. PMID:22143683

  19. Discrimination in waiting times by insurance type and financial soundness of German acute care hospitals.

    PubMed

    Schwierz, Christoph; Wübker, Achim; Wübker, Ansgar; Kuchinke, Björn A

    2011-10-01

    This paper shows that patients with private health insurance (PHI) are being offered significantly shorter waiting times than patients with statutory health insurance (SHI) in German acute hospital care. This behavior may be driven by the higher expected profitability of PHI relative to SHI holders. Further, we find that hospitals offering private insurees shorter waiting times when compared with SHI holders have a significantly better financial performance than those abstaining from or with less discrimination.

  20. Modified Tumescent Solution for Creating Working Space During Endoscopic Thyroidectomy.

    PubMed

    Zhang, Li-Yong; Zhao, Wen-Xin; Wang, Bo; Yan, Shou-Yi; Wen, Jia

    2018-04-01

    To study the feasibility of gas-liquid mixing tumescent solution for creating a working space (WS) in endoscopic thyroidectomy (ET). A prospective study was performed on 186 patients with thyroid tumor who had undergone ET via chest and breast approach. Patients were randomly divided into 2 groups to receive traditional tumescent solution as group A and modified tumescent solution (gas-liquid mixing tumescent solution) as group B. This study compares the following surgical outcome parameters between the 2 groups, including changes of blood pressure, heart rate, and oxygen saturation before and after creating a WS, time for creating a WS, operative time, hemorrhage volume for creating a WS, overall hemorrhage volume, overall postoperative drainage volume, postoperative pain score, postoperative hospitalization, number of retrieved lymph nodes, total serum calcium, serum parathyroid hormone, and cases of transient and permanent recurrent laryngeal nerve palsy. No postoperative bleeding, permanent recurrent laryngeal nerve palsy, incision and surgical site infection, air embolism, flap injury occurred in both groups. The mean time for creating a WS and the whole operation in group B was significantly shorter than that in group A ( P < .05). There were no statistically significant differences in both groups in terms of other observation index ( P > .05). The clinical application of gas-liquid mixing tumescent solution can effectively reduce the time for creating a WS and whole operative time, and worthy of being widely used in ET as a safe and effective technique.

  1. Virtual reality training for surgical trainees in laparoscopic surgery.

    PubMed

    Nagendran, Myura; Gurusamy, Kurinchi Selvan; Aggarwal, Rajesh; Loizidou, Marilena; Davidson, Brian R

    2013-08-27

    Standard surgical training has traditionally been one of apprenticeship, where the surgical trainee learns to perform surgery under the supervision of a trained surgeon. This is time-consuming, costly, and of variable effectiveness. Training using a virtual reality simulator is an option to supplement standard training. Virtual reality training improves the technical skills of surgical trainees such as decreased time for suturing and improved accuracy. The clinical impact of virtual reality training is not known. To assess the benefits (increased surgical proficiency and improved patient outcomes) and harms (potentially worse patient outcomes) of supplementary virtual reality training of surgical trainees with limited laparoscopic experience. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library, MEDLINE, EMBASE and Science Citation Index Expanded until July 2012. We included all randomised clinical trials comparing virtual reality training versus other forms of training including box-trainer training, no training, or standard laparoscopic training in surgical trainees with little laparoscopic experience. We also planned to include trials comparing different methods of virtual reality training. We included only trials that assessed the outcomes in people undergoing laparoscopic surgery. Two authors independently identified trials and collected data. We analysed the data with both the fixed-effect and the random-effects models using Review Manager 5 analysis. For each outcome we calculated the mean difference (MD) or standardised mean difference (SMD) with 95% confidence intervals based on intention-to-treat analysis. We included eight trials covering 109 surgical trainees with limited laparoscopic experience. Of the eight trials, six compared virtual reality versus no supplementary training. One trial compared virtual reality training versus box-trainer training and versus no supplementary training, and one trial compared virtual reality training versus box-trainer training. There were no trials that compared different forms of virtual reality training. All the trials were at high risk of bias. Operating time and operative performance were the only outcomes reported in the trials. The remaining outcomes such as mortality, morbidity, quality of life (the primary outcomes of this review) and hospital stay (a secondary outcome) were not reported. Virtual reality training versus no supplementary training: The operating time was significantly shorter in the virtual reality group than in the no supplementary training group (3 trials; 49 participants; MD -11.76 minutes; 95% CI -15.23 to -8.30). Two trials that could not be included in the meta-analysis also showed a reduction in operating time (statistically significant in one trial). The numerical values for operating time were not reported in these two trials. The operative performance was significantly better in the virtual reality group than the no supplementary training group using the fixed-effect model (2 trials; 33 participants; SMD 1.65; 95% CI 0.72 to 2.58). The results became non-significant when the random-effects model was used (2 trials; 33 participants; SMD 2.14; 95% CI -1.29 to 5.57). One trial could not be included in the meta-analysis as it did not report the numerical values. The authors stated that the operative performance of virtual reality group was significantly better than the control group. Virtual reality training versus box-trainer training: The only trial that reported operating time did not report the numerical values. In this trial, the operating time in the virtual reality group was significantly shorter than in the box-trainer group. Of the two trials that reported operative performance, only one trial reported the numerical values. The operative performance was significantly better in the virtual reality group than in the box-trainer group (1 trial; 19 participants; SMD 1.46; 95% CI 0.42 to 2.50). In the other trial that did not report the numerical values, the authors stated that the operative performance in the virtual reality group was significantly better than the box-trainer group. Virtual reality training appears to decrease the operating time and improve the operative performance of surgical trainees with limited laparoscopic experience when compared with no training or with box-trainer training. However, the impact of this decreased operating time and improvement in operative performance on patients and healthcare funders in terms of improved outcomes or decreased costs is not known. Further well-designed trials at low risk of bias and random errors are necessary. Such trials should assess the impact of virtual reality training on clinical outcomes.

  2. Early age noise exposure increases loudness perception - A novel animal model of hyperacusis.

    PubMed

    Alkharabsheh, Ana'am; Xiong, Fen; Xiong, Binbin; Manohar, Senthilvelan; Chen, Guangdi; Salvi, Richard; Sun, Wei

    2017-04-01

    The neural mechanisms that give rise to hyperacusis, a reduction in loudness tolerance, are largely unknown. Some reports suggest that hyperacusis is linked to childhood hearing loss. However, the evidence for this is largely circumstantial. In order to rigorously test this hypothesis, we studied loudness changes in rats caused by intense noise exposure (12 kHz narrow band noise, 115 dB SPL, 4 h) at postnatal 16 days. Rats without noise exposure were used as controls. The exposed noise group (n = 7) showed a mean 40-50 dB hearing loss compared to the control group (n = 8) at high frequencies (>= 8 kHz) and less hearing loss at lower frequencies. Loudness was evaluated using sound reaction time and loudness response functions in an operant conditioning-based behavioral task using narrow-band noise (40-110 dB SPL, centered at 2, 4 and 12 kHz). Interestingly, the sound reaction time of the noise group was significantly shorter than the control group at supra-threshold levels. The average reaction time was less than 100 ms in the noise group at 100 dB SPL, which was three times shorter than the control group. Our results indicate that early noise-induced hearing loss leads to a significant increase of loudness, a behavior indicative of hyperacusis. Our results are consistent with clinical reports suggesting that hearing loss at an early age is a significant risk factor for hyperacusis. Published by Elsevier B.V.

  3. Additional band broadening of peptides in the first size-exclusion chromatographic dimension of an automated stop-flow two-dimensional high performance liquid chromatography.

    PubMed

    Xu, Jucai; Sun-Waterhouse, Dongxiao; Qiu, Chaoying; Zhao, Mouming; Sun, Baoguo; Lin, Lianzhu; Su, Guowan

    2017-10-27

    The need to improve the peak capacity of liquid chromatography motivates the development of two-dimensional analysis systems. This paper presented a fully automated stop-flow two-dimensional liquid chromatography system with size exclusion chromatography followed by reversed phase liquid chromatography (SEC×RPLC) to efficiently separate peptides. The effects of different stop-flow operational parameters (stop-flow time, peak parking position, number of stop-flow periods and column temperature) on band broadening in the first dimension (1 st D) SEC column were quantitatively evaluated by using commercial small proteins and peptides. Results showed that the effects of peak parking position and the number of stop-flow periods on band broadening were relatively small. Unlike stop-flow analysis of large molecules with a long running time, additional band broadening was evidently observed for small molecule analytes due to the relatively high effective diffusion coefficient (D eff ). Therefore, shorter analysis time and lower 1 st D column temperature were suggested for analyzing small molecules. The stop-flow two-dimensional liquid chromatography (2D-LC) system was further tested on peanut peptides and an evidently improved resolution was observed for both stop-flow heart-cutting and comprehensive 2D-LC analysis (in spite of additional band broadening in SEC). The stop-flow SEC×RPLC, especially heart-cutting analysis with shorter analysis time and higher 1 st D resolution for selected fractions, offers a promising approach for efficient analysis of complex samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. A prospective, randomised trial comparing closed intramedullary nailing with percutaneous plating in the treatment of distal metaphyseal fractures of the tibia.

    PubMed

    Guo, J J; Tang, N; Yang, H L; Tang, T S

    2010-07-01

    We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients' age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware. We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p < 0.001, and 97.9 vs 81.2 minutes, p < 0.001, respectively).After one year, all the fractures had united. Patients who had intramedullary nailing had a higher mean pain score (40 = no pain, 0 = severe pain), [corrected] but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed. We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with these fractures.

  5. Comparison of clinical results between novel percutaneous pedicle screw and traditional open pedicle screw fixation for thoracolumbar fractures without neurological deficit.

    PubMed

    Yang, Ming; Zhao, Qinpeng; Hao, Dingjun; Chang, Zhen; Liu, Shichang; Yin, Xinhua

    2018-06-16

    To compare the efficacy and safety of novel percutaneous minimally invasive pedicle screw fixation and traditional open surgery for thoracolumbar fractures without neurological deficit. Sixty adult patients with single thoracolumbar fracture between June 2014 and June 2016 were recruited in this study, randomly divided into open fixation group (group A) or minimally invasive percutaneous fixation group (group B). Clinical and surgical evaluation including surgery time, blood losses, radiation times, hospital stay, and complication were performed. The two groups of patients with pre-operative and last follow-up anterior height ratio of fracture vertebral, Cobb angle of fracture vertebral, and VAS score of back pain were compared. All patients completed valid follow-ups, with an average time period of 15.4 months (12-26 months). Group B achieved much better results in time of operation, intra-operative blood loss, and length of stay than group A (P < 0.05). Group A was significantly better than group B in the times of radiation (P < 0.05). The VAS score was significantly lower in group B than in group A at three days after the operation (P < 0.05). There were no significant differences between the two groups in the anterior height ratio of fracture vertebral, Cobb angle, and VAS score in the last follow-up (P > 0.05). No injured nerve or other severe complications occurred in both groups; one of the patients from group A had back and loin pain lasting for about one month, which resolved after analgesia and functional training. There was no significant difference between the two groups in incidence of complications. Novel percutaneous pedicle screws with angle reset function can achieve the same effect as traditional open pedicle screw fixation in the treatment of thoracolumbar fractures without nerve injuries. Percutaneous minimally invasive pedicle screw fixation has the characteristics of shorter operative time, less bleeding, and less pain, but it needs more radiation times.

  6. Evaluation of clinical curative effects of disposable stitching instrument in redundant prepuce patients

    PubMed Central

    Wang, Haitao; Chen, Ningjie; Huo, Ran; Yang, Jincun; Li, Xia; Xing, Nan

    2017-01-01

    The present study aimed to investigate the clinical curative effect of disposable stitching instrument operation in patients with redundant prepuce or phimosis. A total of 102 cases of patients with circumcision were randomly selected (from June 2013 to December 2014) from the department of plastic and aesthetic surgery of our hospital and were randomly divided into control and observation groups (n=51). Patients in the control group were treated by traditional circumcision operation, while patients in the observation group were treated by novel disposable circumcision stitching instrument. Operation time, bleeding volume, incision healing time, postoperative complications and incision aesthetic satisfaction in the groups were observed. As a result, intraoperative bleeding volume of patients in the observation group was significantly less in comparison to the control group. Operation time and incision healing time of patients in the observation group was shorter than that of the control group. Additionally, the incidence of postoperative complications of patients in the observation group was noted to be lower than that of the control group. On the other hand, the incision aesthetic satisfaction of patients in the observation group was higher than that of the control group. Blood vessel counting and nerve fiber counting of tissue specimen in the observation group were more than those of the control group. Postoperative VAS scores of patients in the observation group were significantly lower than that of the control group. Each rating scale scores of EPQ of patients in the observation group improved significantly compared with that of the control group. In conclusion, the present findings show that disposable circumcision stitching instrument operation is more advantageous in comparison to the traditional procedure along with minimal compilations and better post surgery health condition of patients. PMID:28672929

  7. RWPV bioreactor mass transport: earth-based and in microgravity

    NASA Technical Reports Server (NTRS)

    Begley, Cynthia M.; Kleis, Stanley J.

    2002-01-01

    Mass transport and mixing of perfused scalar quantities in the NASA Rotating Wall Perfused Vessel bioreactor are studied using numerical models of the flow field and scalar concentration field. Operating conditions typical of both microgravity and ground-based cell cultures are studied to determine the expected vessel performance for both flight and ground-based control experiments. Results are presented for the transport of oxygen with cell densities and consumption rates typical of colon cancer cells cultured in the RWPV. The transport and mixing characteristics are first investigated with a step change in the perfusion inlet concentration by computing the time histories of the time to exceed 10% inlet concentration. The effects of a uniform cell utilization rate are then investigated with time histories of the outlet concentration, volume average concentration, and volume fraction starved. It is found that the operating conditions used in microgravity produce results that are quite different then those for ground-based conditions. Mixing times for microgravity conditions are significantly shorter than those for ground-based operation. Increasing the differential rotation rates (microgravity) increases the mixing and transport, while increasing the mean rotation rate (ground-based) suppresses both. Increasing perfusion rates enhances mass transport for both microgravity and ground-based cases, however, for the present range of operating conditions, above 5-10 cc/min there are diminishing returns as much of the inlet fluid is transported directly to the perfusion exit. The results show that exit concentration is not a good indicator of the concentration distributions in the vessel. In microgravity conditions, the NASA RWPV bioreactor with the viscous pump has been shown to provide an environment that is well mixed. Even when operated near the theoretical minimum perfusion rates, only a small fraction of the volume provides less than the required oxygen levels. 2002 Wiley Periodicals, Inc.

  8. RWPV bioreactor mass transport: earth-based and in microgravity.

    PubMed

    Begley, Cynthia M; Kleis, Stanley J

    2002-11-20

    Mass transport and mixing of perfused scalar quantities in the NASA Rotating Wall Perfused Vessel bioreactor are studied using numerical models of the flow field and scalar concentration field. Operating conditions typical of both microgravity and ground-based cell cultures are studied to determine the expected vessel performance for both flight and ground-based control experiments. Results are presented for the transport of oxygen with cell densities and consumption rates typical of colon cancer cells cultured in the RWPV. The transport and mixing characteristics are first investigated with a step change in the perfusion inlet concentration by computing the time histories of the time to exceed 10% inlet concentration. The effects of a uniform cell utilization rate are then investigated with time histories of the outlet concentration, volume average concentration, and volume fraction starved. It is found that the operating conditions used in microgravity produce results that are quite different then those for ground-based conditions. Mixing times for microgravity conditions are significantly shorter than those for ground-based operation. Increasing the differential rotation rates (microgravity) increases the mixing and transport, while increasing the mean rotation rate (ground-based) suppresses both. Increasing perfusion rates enhances mass transport for both microgravity and ground-based cases, however, for the present range of operating conditions, above 5-10 cc/min there are diminishing returns as much of the inlet fluid is transported directly to the perfusion exit. The results show that exit concentration is not a good indicator of the concentration distributions in the vessel. In microgravity conditions, the NASA RWPV bioreactor with the viscous pump has been shown to provide an environment that is well mixed. Even when operated near the theoretical minimum perfusion rates, only a small fraction of the volume provides less than the required oxygen levels. 2002 Wiley Periodicals, Inc.

  9. Closure of colostomy.

    PubMed Central

    Beck, P H; Conklin, H B

    1975-01-01

    We analyzed the records of 77 cases of loop colostomy closure in Vietnam War Casualties. All records were complete from the date of injury to discharge following colostomy closure. Simple of the loop colostomy was performed in 44 patients and resection of the stoma and reanastomosis of bowel segments was performed in 33 patients. Average operating time for simple closure of the loop was 70 minutes compared to 115 minutes for resection and anastomosis. Nasogastric suction was used less frequently and for a shorter time with simple loop closure. The total postoperative complication rate was 9% with simple loop closure as compared to 24% for resection and anastomosis. Simple closure of the loop described in this report is technically easier and as safe as resection of the stoma and reanastomosis. Images Fig. 1. PMID:1094967

  10. Gaussian mixture models as flux prediction method for central receivers

    NASA Astrophysics Data System (ADS)

    Grobler, Annemarie; Gauché, Paul; Smit, Willie

    2016-05-01

    Flux prediction methods are crucial to the design and operation of central receiver systems. Current methods such as the circular and elliptical (bivariate) Gaussian prediction methods are often used in field layout design and aiming strategies. For experimental or small central receiver systems, the flux profile of a single heliostat often deviates significantly from the circular and elliptical Gaussian models. Therefore a novel method of flux prediction was developed by incorporating the fitting of Gaussian mixture models onto flux profiles produced by flux measurement or ray tracing. A method was also developed to predict the Gaussian mixture model parameters of a single heliostat for a given time using image processing. Recording the predicted parameters in a database ensures that more accurate predictions are made in a shorter time frame.

  11. A characterization of persistence at short times in the WFC3/IR detector

    NASA Astrophysics Data System (ADS)

    Gennaro, M.; Bajaj, V.; Long, K.

    2018-05-01

    Persistence in the WFC3/IR detector appears to decay as a power law as a function of time elapsed since the end of a stimulus. In this report we study departures from the power law at times shorter than a few hundreds seconds after the stimulus. In order to have better short-time cadence, we use the Multiaccum (.ima) files, which trace the accumulated charge in the pixels as function of time, rather than the final pipeline products (.flt files), which instead report the electron rate estimated via a linear fit to the accumulated charge vs. time relation. We note that at short times after the stimulus, the absolute change in persistence is the strongest, thus a linear fit to the accumulated signal (the .flt values) can be a poor representation of the strongly varying persistence signal. The already observed power-law decay of the persistence signal, still holds at shorter times, with typical values of the power law index, gamma in [-0.8,-1] for stimuli that saturate the WFC3 pixels. To a good degree of approximation, a single power law is a good fit to the persistence signal decay from 100 to 5000 seconds. We also detect a tapering-off in the power-law decay at increasingly shorter times. This change in behavior is of the order of Delta Gamma 0.02 - 0.05 when comparing power-law fits performed to the persistence signal from 0 up to 250 seconds and from 0 up to 4000 seconds after the stimulus, indicating that persistence decays slightly more rapidly as time progresses. Our results may suggest that for even shorter times, not probed by our study, the WFC3 persistence signal might deviate from a single power-law model.

  12. Impact of adherence to standard operating procedures for pneumonia on outcome of intensive care unit patients.

    PubMed

    Nachtigall, Irit; Tamarkin, Andrey; Tafelski, Sascha; Deja, Maria; Halle, Elke; Gastmeier, Petra; Wernecke, Klaus D; Bauer, Torsten; Kastrup, Marc; Spies, Claudia

    2009-01-01

    Pneumonia accounts for almost half of intensive care unit (ICU) infections and nearly 60% of deaths from nosocomial infections. It increases hospital stay by 7-9 days, crude mortality by 70% and attributable mortality by 30%. Our purpose was to assess the impact of standard operating procedures adapted to the local resistance rates in the initial empirical treatment for pneumonia on duration of first pneumonia episode, duration of mechanical ventilation, and length of ICU stay. Prospective observational cohort study with retrospective expert audit. Five anesthesiologically managed ICUs at University hospital (one cardio-surgical, one neurosurgical, two interdisciplinary, and one intermediate care). Of 524 consecutive patients with > or = 36 hr ICU treatment 131 patients with pneumonia on ICU were identified. Their first pneumonia episode was evaluated daily for adherence to standard operating procedures. Pneumonia was diagnosed according to the American Thoracic Society guidelines. Patients with > 70% compliance were assigned to high adherence group (HAG), patients with < or = 70% to low adherence group (LAG). HAG consisted of 45 (49 first episode) patients, LAG of 86 (82 first episode) patients, respectively. Mean duration of treatment of the first pneumonia episode was 10.11 +/- 7.95 days in the LAG and 6.22 +/- 3.27 days in the HAG (p = 0.001). Duration of mechanical ventilation was 317.59 +/- 336.18 hrs in the LAG and 178.07 +/- 191.33 hrs in the HAG (p = 0.017). Length of ICU stay was 20.24 +/- 16.59 days in the LAG and 12.04 +/- 10.42 days in the HAG (p = 0.001). Barriers in compliance need further evaluation. Adherence to standard operating procedure is associated with a shorter duration of treatment of first pneumonia episode, a shorter duration of mechanical ventilation, and a shorter ICU stay.

  13. Concept of Operations Evaluation for Using Remote-Guidance Ultrasound for Exploration Spaceflight.

    PubMed

    Hurst, Victor W; Peterson, Sean; Garcia, Kathleen; Ebert, Douglas; Ham, David; Amponsah, David; Dulchavsky, Scott

    2015-12-01

    Remote-guidance (RG) techniques aboard the International Space Station (ISS) have enabled astronauts to collect diagnostic-level ultrasound (US) images. Exploration-class missions will likely require nonformally trained sonographers to operate with greater autonomy given longer communication delays (> 6 s for missions beyond the Moon) and blackouts. Training requirements for autonomous collection of US images by non-US experts are being determined. Novice US operators were randomly assigned to one of three groups to collect standardized US images while drawing expertise from A) RG only, B) a computer training tool only, or C) both RG and a computer training tool. Images were assessed for quality and examination duration. All operators were given a 10-min standardized generic training session in US scanning. The imaging task included: 1) bone fracture assessment in a phantom and 2) Focused Assessment with Sonography in Trauma (FAST) examination in a healthy volunteer. A human factors questionnaire was also completed. Mean time for group B during FAST was shorter (20.4 vs. 22.7 min) than time for the other groups. Image quality scoring was lower than in groups A or C, but all groups produced images of acceptable diagnostic quality. RG produces US images of higher quality than those produced with only computer-based instruction. Extended communication delays in exploration missions will eliminate the option of real-time guidance, thus requiring autonomous operation. The computer program used appears effective and could be a model for future digital US expertise banks. Terrestrially, it also provides adequate self-training and mentoring mechanisms.

  14. Surgery for patients with primary hyperparathyroidism and negative sestamibi scintigraphy--a feasibility study.

    PubMed

    Thier, Mark; Nordenström, Erik; Bergenfelz, Anders; Westerdahl, Johan

    2009-09-01

    We report the surgical treatment of a consecutive series of scan negative patients with the intention of unilateral parathyroid exploration with the aid of intraoperative quick PTH (qPTH). The study included 35 consecutive sestamibi scan negative patients (27 women, eight men) with sporadic pHPT subjected to first time surgery. Median age was 70 years and median preoperative calcium level 2.8 mmol/L. Thirty-three patients had a histological diagnosis of a parathyroid adenoma (median weight 0.48 g [range 0.12 g-2.5 g]). Nineteen patients were explored bilaterally and 16 patients (46%) were operated unilaterally. The median operation time was 40 min in the unilateral group and 95 min in the bilateral group (p < 0.001). Three patients were treated for postoperative hypocalcemia after bilateral exploration versus none in the unilateral group (p = 0.23). With a minimum of 12 months of follow-up, 33 patients (94.3%) were cured. One case of recurrent HPT presented after bilateral exploration with visualization of four glands. One case of persistent HPT was observed after unilateral exploration. qPTH was predictive of operative failure in both patients. Forty-six percent of the patients in our study could be operated unilaterally with a total cure rate of 94%. Patients in the unilateral group had a significant shorter operation time and a lower incidence of postoperative hypocalcemia. In conclusion our investigation shows that limited parathyroid exploration can safely be performed on patients with negative sestamibi scintigraphy by the aid of qPTH.

  15. Robotic Enucleation for Benign or Borderline Tumours of the Pancreas: A Retrospective Analysis and Comparison from a High-Volume Centre in Asia.

    PubMed

    Jin, Jia-Bin; Qin, Kai; Li, Hua; Wu, Zhi-Chong; Zhan, Qian; Deng, Xia-Xing; Chen, Hao; Shen, Bai-Yong; Peng, Cheng-Hong; Li, Hong-Wei

    2016-12-01

    Enucleation is increasingly performed for benign or borderline tumours of the pancreas because it is a parenchyma-sparing and less invasive procedure compared to conventional pancreatectomy, which reduces the risk of exocrine and endocrine insufficiency. This study retrospectively evaluated and compared the pre-, intra-, and post-operative clinical characteristics after open and robotic approaches for pancreatic enucleation. Fifty-six cases of enucleation for benign or borderline tumours of the pancreas treated from March 2010 to July 2015 were identified by a retrospective search. These included 25 patients who underwent an open approach and 31 patients who underwent a robotic approach. The clinical characteristics were extracted and compared. The two groups had a similar location and pathology of the tumour. The robotic group had a significantly shorter operation time and significantly less blood loss than the open group. The rates of clinical pancreatic fistula (PF) formation and major complications were similar. The robotic approach could be applied for a tumour on the right side of the pancreas without increasing the incidence of clinical PF or other major complications. The patients with clinical PF had a significantly shorter distance between the lesion and the main pancreatic duct (MPD). Robotic enucleation appears to be a feasible and safe approach for benign or borderline tumours of the pancreas and was associated with similarly favourable surgical outcomes as the open approach. Identifying and avoiding the MPD is an important step during enucleation.

  16. Benefit from NASA

    NASA Image and Video Library

    1997-01-01

    A special lighting technology was developed for space-based commercial plant growth research on NASA's Space Shuttle. Surgeons have used this technology to treat brain cancer on Earth, in two successful operations. The treatment technique, called Photodynamic Therapy, requires the surgeon to use tiny, pinhead-size Light Emitting Diodes (LEDs) (a source that releases long wavelengths of light ) to activate light-sensitive, tumor-treating drugs. "A young woman operated on in May 1999 has fully recovered with no complications and no evidence of the tumor coming back," said Dr. Harry Whelan, a pediatric neurologist at the Medical Hospital of Wisconsin in Milwaukee. Laser light has been used for this type of surgery in the past, but the LED light illuminates through all nearby tissues, reaching parts of a tumor that shorter wavelengths of laser light carnot. The new probe is safer because the longer wavelengths of light are cooler than the shorter wavelengths of laser light, making the LED less likely to injure normal brain tissue near the tumor. It can be used for hours at a time while still remaining cool to the touch. The LED light source is compact, about the size of a briefcase, and can be purchased for a fraction of the cost of a laser. The LEDs, developed and managed by NASA's Marshall Space Flight Center, have been used on seven Space Shuttle flights inside the Microgravity Astroculture Facility. This technology has also been successfully used to further commercial research in crop growth.

  17. New Technique for Caesarean Section

    PubMed Central

    Vejnović, T. R.; Costa, S. D.; Ignatov, A.

    2012-01-01

    Caesarean section is one of the most common operations worldwide and more than 30 % of procedures in perinatal centres in Germany are caesarean sections. In the last few years the technique used for caesarean sections has been simplified, resulting in a lower postoperative morbidity. But persistent problems associated with all caesarean section techniques include high intraoperative loss of blood, the risk of injury to the child during uterotomy and postoperative wound dehiscence of the uterine scar. We present here a modification of the most common Misgav-Ladach method. The initial skin incision is done along the natural skin folds and is extended intraoperatively depending on the circumference of the babyʼs head. After blunt expansion of the uterine incision using an anatomical forceps, the distal uterine wall is pushed behind the babyʼs head. The babyʼs head is rotated into the occipito-anterior or posterior position and delivery occurs through the application of gentle pressure on the uterine fundus. Closure of the uterotomy is done using 2 continuous sutures, which are then knotted together resulting in a short double-layer closure. The two ends of the skin suture are left open to allow for natural drainage. Our experience at the University Gynaecological Hospitals in Novi Sad and Magdeburg has shown that this modification is associated with shorter operating times, minimal blood loss and shorter in-hospital stay of patients as well as high rates of patient satisfaction. PMID:25328165

  18. Light Emitting Diodes (LEDs)

    NASA Technical Reports Server (NTRS)

    1997-01-01

    A special lighting technology was developed for space-based commercial plant growth research on NASA's Space Shuttle. Surgeons have used this technology to treat brain cancer on Earth, in two successful operations. The treatment technique, called Photodynamic Therapy, requires the surgeon to use tiny, pinhead-size Light Emitting Diodes (LEDs) (a source that releases long wavelengths of light ) to activate light-sensitive, tumor-treating drugs. 'A young woman operated on in May 1999 has fully recovered with no complications and no evidence of the tumor coming back,' said Dr. Harry Whelan, a pediatric neurologist at the Medical Hospital of Wisconsin in Milwaukee. Laser light has been used for this type of surgery in the past, but the LED light illuminates through all nearby tissues, reaching parts of a tumor that shorter wavelengths of laser light carnot. The new probe is safer because the longer wavelengths of light are cooler than the shorter wavelengths of laser light, making the LED less likely to injure normal brain tissue near the tumor. It can be used for hours at a time while still remaining cool to the touch. The LED light source is compact, about the size of a briefcase, and can be purchased for a fraction of the cost of a laser. The LEDs, developed and managed by NASA's Marshall Space Flight Center, have been used on seven Space Shuttle flights inside the Microgravity Astroculture Facility. This technology has also been successfully used to further commercial research in crop growth.

  19. 25G compared with 20G vitrectomy under Resight non-contact wide-angle lenses for Terson syndrome.

    PubMed

    Mao, Xinbang; You, Zhipeng

    2017-08-01

    The aim of the present study was to compare the effectiveness of 25G vitrectomy to standard 20G vitrectomy for treatment of Terson syndrome under Resight non-contact wide-angle lenses. This was a case-control study of 20 patients with Terson syndrome (study group) that underwent 25G vitrectomy under Resight non-contact wide-angle lenses, with those of 20 matched patients that underwent 20G vitrectomy (control group). Medical records were reviewed from between July 2011 and October 2013. Data included results of the Early Treatment Diabetic Retinopathy Study examination, ophthalmology B-scan ultrasonography and fundus photography. The mean age, follow-up time, the preoperative visual acuity of LogMAR and the preoperative intraocular pressure (IOP) were all comparable in the two groups (all P>0.05). There were statistically significant differences in postoperative visual acuity of LogMAR compared with preoperative visual acuity (P<0.001) in both groups, but no difference between the groups (P=0.845). However, the operative times (13.5 min in study group vs. 42 min in control group) and post-operative IOP at day 1 (13.5 vs. 20 mmHg) were significantly reduced in the study group compared to the control group (P<0.001). Therefore, the present findings suggest that 25G Vitrectomy for Terson syndrome under Resight non-contact wide-angle lenses can achieve a significantly shorter operative time and lower post-operative IOP compared with 20G Vitrectomy.

  20. The limited role of recombination energy in common envelope removal

    NASA Astrophysics Data System (ADS)

    Grichener, Aldana; Sabach, Efrat; Soker, Noam

    2018-05-01

    We calculate the outward energy transport time by convection and photon diffusion in an inflated common envelope and find this time to be shorter than the envelope expansion time. We conclude therefore that most of the hydrogen recombination energy ends in radiation rather than in kinetic energy of the outflowing envelope. We use the stellar evolution code MESA and inject energy inside the envelope of an asymptotic giant branch star to mimic energy deposition by a spiraling-in stellar companion. During 1.7 years the envelope expands by a factor of more than 2. Along the entire evolution the convection can carry the energy very efficiently outwards, to the radius where radiative transfer becomes more efficient. The total energy transport time stays within several months, shorter than the dynamical time of the envelope. Had we included rapid mass loss, as is expected in the common envelope evolution, the energy transport time would have been even shorter. It seems that calculations that assume that most of the recombination energy ends in the outflowing gas might be inaccurate.

  1. Using low frequency and intensity ultrasound to enhance start-up and operation performance of Anammox process inoculated with the conventional sludge.

    PubMed

    Wang, Tao; Zhang, Diandian; Sun, Yating; Zhou, Shanshan; Li, Lin; Shao, Jingjing

    2018-04-01

    A lab-scale ultrasound enhancing Anammox reactor (R1) was established and irradiated once a week by ultrasound with the optimal parameter (frequency of 25 kHz, intensity of 0.2 W cm -2 and exposure time of 3 min) obtained by batch experiments. R1 and the controlled Anammox reactor (R2) without exposure to the ultrasound were operated in parallel. The start-up period of Anammox process (53 days) in R1 was shorter than that (61 days) in R2. The nitrogen loading-enhancing period (day 53-day 135) in R1 was also shorter than that (day 61-day 151) in R2. At the end of the nitrogen loading-enhancing period, NLR (0.76 kg N m -3  d -1 ) and NRR (0.68 kg N m -3  d -1 ) of R1 were both higher than NLR (0.66 kg N m -3  d -1 ) and NRR (0.56 kg N m -3  d -1 ) of R2. Moreover, The stability of Anammox process in R1 was better than that in R2. The results demonstrated that the periodical irradiation of ultrasound enhanced the start-up and operational performance of Anammox reactor. Microbial community analysis indicated that the ultrasound accelerated the microbial succession from some other bacteria to Anammox bacteria so that shorten the start-up period of Anammox process from the conventional activated sludge. It also indicated that the ultrasound strengthened the competitive advantage of Candidatus Kuenenia stuttgartiensis in Anammox bacteria of the mature sludge so as to enhance the nitrogen removal performance of the Anammox reactor under the operation condition of high nitrogen loading. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Comparison of Delta-Shape Anastomosis and Extracorporeal Billroth I Anastomosis after Laparoscopic Distal Gastrectomy for Gastric Cancer: A Systematic Review with Meta-Analysis of Short-Term Outcomes.

    PubMed

    Hu, Geng-Yuan; Tao, Feng; Ji, Ke-Wei; Wang, Wei

    2016-01-01

    The aim of this systematic review and meta-analysis is to evaluate the safety and relative benefits of delta-shape anastomosis (DA) by comparing to conventional laparoscopy-assisted distal gastrectomy with Billroth I gastroduodenostomy (LADG BI). Studies and relevant literature regarding DA versus LADG BI were searched in the electronic databases. Operation time, postoperative complications, estimated blood loss, number of retrieved lymph nodes, time to first flatus, time to oral intake, length of postoperative hospitalization in DA and LADG BI were pooled and compared using meta-analysis. Weighted mean differences (WMDs) and odds ratios (ORs) were calculated with 95% confidence intervals (CIs) to evaluate the effect of DA. Eight studies of 1739 patients were included in the meta-analysis. Compared with LADG BI, DA had shorter postoperative hospitalization (WMD = -0.47, 95%CI: -0.69 to -0.25, P<0.01), less blood loss (WMD = - 25.90, 95%CI: -43.11 to -8.70, P<0.01), shorter time to oral intake (WMD = -0.25, 95%CI: -0.49 to -0.01, P = 0.04), and more retrieved lymph nodes (WMD = 1.36, 95%CI: 0.30 to 2.43, P = 0.01). Operation time (WMD = -0.07, 95%CI -15.58 to 15.43, P = 0.99), overall postoperative complication rate (OR = 1.05, 95%CI: 0.74 to 1.49, P = 0.63), surgical complication rate (OR = 1.02, 95%CI: 0.70 to 1.49, P = 0.90), nonsurgical complication rate (OR = 1.21, 95%CI: 0.54 to 2.72, P = 0.64), leakage rate (OR = 2.54, 95%CI: 0.92 to 7.01, P = 0.07), stricture rate (OR = 0.36, 95%CI: 0.09 to 1.44, P = 0.15), wound complication rate (OR = 0.71, 95%CI: 0.33 to 1.55, P = 0.39), time to first flatus (WMD = -0.10, 95%CI: -0.27 to 0.07, P = 0.26), and proximal surgical margin (WMD = -0.25, 95%CI: -1.14 to 0.65, P = 0.59) was not statistically different. Compared with LADG BI, DA is a safe and feasible procedure, with significantly reduced blood loss, time to oral intake, and postoperative hospitalization.

  3. Prospective, randomized comparison of a prototype endoscope with deflecting working channels versus a conventional double-channel endoscope for rectal endoscopic submucosal dissection in an established experimental simulation model (with video).

    PubMed

    Jung, Yunho; Kato, Masayuki; Lee, Jongchan; Gromski, Mark A; Chuttani, Ram; Matthes, Kai

    2013-11-01

    A prototype endoscope was designed to improve visualization and dissection of tissue with the use of 2 working channels with different deflections. To evaluate the efficacy and operability of a prototype endoscope in comparison with a conventional double-channel endoscope for rectal endoscopic submucosal dissection (ESD). Randomized, prospective, controlled, ex vivo study. Academic medical center. A total of 80 standardized artificial lesions measuring 3 × 3 cm were created approximately 5 cm from the anal verge in fresh ex vivo porcine colorectal specimens. Two endoscopists each completed 20 cases with the prototype endoscope and 20 cases with the conventional endoscope. An independent observer recorded procedure time, specimen size, en bloc resection, and perforation rate. For the ESD novice, the mean submucosal dissection time (10.5 ± 3.8 vs 14.9 ± 7.3 minutes; P = .024) and total procedure time (18.1 ± 5.2 vs 23.6 ± 8.2 minutes; P = .015) were significantly shorter in the prototype group in comparison with the conventional group. For the ESD expert, there was no significant difference between the mean circumferential resection, submucosal dissection, and total procedure time (prototype group 14.2 ± 6.0 minutes, conventional group 14.2 ± 8.8 minutes; P = .992). The overall perforation and en bloc resection rates were not significantly different between groups. Ex vivo study. In this ex vivo prospective comparison study, there was a technical advantage for the ESD novice with the prototype endoscope that resulted in a shorter procedure time, which was not observed for cases performed by the ESD expert. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  4. Remotely controlled steerable sheath improves result and procedural parameters of atrial fibrillation ablation with magnetic navigation.

    PubMed

    Errahmouni, Abdelkarim; Latcu, Decebal Gabriel; Bun, Sok-Sithikun; Rijo, Nicolas; Dugourd, Céline; Saoudi, Nadir

    2015-07-01

    The magnetic navigation (MN) system may be coupled with a new advancement system that fully controls both the catheter and a robotic deflectable sheath (RSh) or with a fixed-curve sheath and a catheter-only advancement system (CAS). We aimed to compare these approaches for atrial fibrillation (AF) ablation. Atrial fibrillation ablation patients (45, 23 paroxysmal and 22 persistent) performed with MN-RSh (RSh group) were compared with a control group (37, 18 paroxysmal and19 persistent) performed with MN-CAS (CAS group). Setup duration was measured from the procedure's start to operator transfer to control room. Ablation step duration was defined as the time from the beginning of the first radiofrequency (RF) pulse to the end of the last one and was separately acquired for the left and the right pulmonary vein (PV) pairs. Clinical characteristics, left atrial size, and AF-type distribution were similar between the groups. Setup duration as well as mapping times was also similar. Ablation step duration for the left PVs was similar, but was shorter for the right PVs in RSh group (46 ± 9 vs. 63 ± 12 min, P < 0.0001). Radiofrequency delivery time (34 ± 9 vs. 40 ± 11 min, P = 0.007) and procedure duration (227 ± 36 vs. 254 ± 62 min, P = 0.01) were shorter in RSh group. No complication occurred in RSh group. During follow-up, there were five recurrences (11%) in RSh group and 11 (29%) in CAS group (P = 0.027). The use of the RSh for AF ablation with MN is safe and improves outcome. Right PV isolation is faster, RF delivery time and procedure time are reduced. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  5. Remotely controlled steerable sheath improves result and procedural parameters of atrial fibrillation ablation with magnetic navigation

    PubMed Central

    Errahmouni, Abdelkarim; Latcu, Decebal Gabriel; Bun, Sok-Sithikun; Rijo, Nicolas; Dugourd, Céline; Saoudi, Nadir

    2015-01-01

    Aims The magnetic navigation (MN) system may be coupled with a new advancement system that fully controls both the catheter and a robotic deflectable sheath (RSh) or with a fixed-curve sheath and a catheter-only advancement system (CAS). We aimed to compare these approaches for atrial fibrillation (AF) ablation. Methods and results Atrial fibrillation ablation patients (45, 23 paroxysmal and 22 persistent) performed with MN–RSh (RSh group) were compared with a control group (37, 18 paroxysmal and19 persistent) performed with MN–CAS (CAS group). Setup duration was measured from the procedure's start to operator transfer to control room. Ablation step duration was defined as the time from the beginning of the first radiofrequency (RF) pulse to the end of the last one and was separately acquired for the left and the right pulmonary vein (PV) pairs. Clinical characteristics, left atrial size, and AF-type distribution were similar between the groups. Setup duration as well as mapping times was also similar. Ablation step duration for the left PVs was similar, but was shorter for the right PVs in RSh group (46 ± 9 vs. 63 ± 12 min, P < 0.0001). Radiofrequency delivery time (34 ± 9 vs. 40 ± 11 min, P = 0.007) and procedure duration (227 ± 36 vs. 254 ± 62 min, P = 0.01) were shorter in RSh group. No complication occurred in RSh group. During follow-up, there were five recurrences (11%) in RSh group and 11 (29%) in CAS group (P = 0.027). Conclusion The use of the RSh for AF ablation with MN is safe and improves outcome. Right PV isolation is faster, RF delivery time and procedure time are reduced. PMID:25662989

  6. A procedure for rapid issue of red cells for emergency use.

    PubMed

    Weiskopf, Richard B; Webb, Mary; Stangle, Deena; Klinbergs, Gunter; Toy, Pearl

    2005-04-01

    A College of American Pathologists Q-Probe revealed that the median turnaround times for emergency requests for red blood cells from the operating room were 30 minutes to release of cells from the blood bank and 34 minutes to delivery to the operating room. These times may not be adequate to permit the red cells to provide sufficiently rapid delivery of oxygen in massively bleeding patients. To improve the time from emergency request for red cells to delivery to the operating room. A new emergency issue program was implemented for only the operating rooms; emergency issue to all other hospital locations remained unchanged. Six units of group O Rh-negative red blood cells (RBCs) are maintained in the blood bank in a separate basket with transfusion forms containing the unit numbers and expiration dates and a bag with one blood tubing segment from each unit. The times to issue and to delivery to the operating room suite were compared with time to issue of 2 group O Rh-negative RBCs for other hospital locations using the older system during the same time period and with the time to issue of 2 units to all other hospital locations during the preceding 2 years. A university hospital. Time between emergency request for red cells and delivery to the operating room. The time between blood bank notification and arrival in the operating room of the 6 units of RBCs was significantly shorter than the time required to just issue (not including delivery time) 2 units of RBCs to other hospital locations. With the new procedure, 82% of units issued reached the operating room within 2 minutes of request, 91% arrived within 3 minutes, and 100% arrived within 4 minutes. These percentages are significantly higher than those for only issue of blood (without delivery) using the older issuing procedure for all hospital locations during the previous 2 years (37%, 49%, and 66%, respectively; P = .007, .009, and .02, respectively) and for other locations during the same 7-month period (29%, 46%, and 73%, respectively; P = .004, .01, and .09, respectively). Time (mean [95% confidence interval]) from blood bank notification to delivery of RBCs to the operating room suite (2.1 [1.6-2.6] minutes, of which approximately 50-60 seconds is attributable to delivery time) was less than issue times (not including delivery times) using the older issuing procedure for other hospital locations during the same period (4.1 [3.1-5.0] minutes; P = .007). An emergency issue procedure can be used to issue several units of RBCs within 1 minute and have them delivered to the operating room within 2 minutes while maintaining sufficient controls and providing required information to satisfy patient and blood bank requirements.

  7. Time compression diseconomies in environmental management: the effect of assimilation on environmental performance.

    PubMed

    Lannelongue, Gustavo; Gonzalez-Benito, Javier; Gonzalez-Benito, Oscar; Gonzalez-Zapatero, Carmen

    2015-01-01

    This research addresses the relationship between an organisation's assimilation of its environmental management system (EMS), the experience it gains through it, and its environmental performance. Assimilation here refers to the degree to which the requirements of the management standard are integrated within a plant's daily operations. Basing ourselves on the heterogeneity of organisations, we argue that assimilation and experience will inform environmental performance. Furthermore, we posit that the relationship between assimilation and environmental performance depends on experience. The attempt to obtain greater assimilation in a shorter time leads an organisation to record a poorer environmental outcome, which we shall refer to as time compression diseconomies in environmental management. We provide empirical evidence based on 154 plants pertaining to firms in Spain subject to the European Union's CO2 Emissions Trading System. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. The optimization of total laboratory automation by simulation of a pull-strategy.

    PubMed

    Yang, Taho; Wang, Teng-Kuan; Li, Vincent C; Su, Chia-Lo

    2015-01-01

    Laboratory results are essential for physicians to diagnose medical conditions. Because of the critical role of medical laboratories, an increasing number of hospitals use total laboratory automation (TLA) to improve laboratory performance. Although the benefits of TLA are well documented, systems occasionally become congested, particularly when hospitals face peak demand. This study optimizes TLA operations. Firstly, value stream mapping (VSM) is used to identify the non-value-added time. Subsequently, batch processing control and parallel scheduling rules are devised and a pull mechanism that comprises a constant work-in-process (CONWIP) is proposed. Simulation optimization is then used to optimize the design parameters and to ensure a small inventory and a shorter average cycle time (CT). For empirical illustration, this approach is applied to a real case. The proposed methodology significantly improves the efficiency of laboratory work and leads to a reduction in patient waiting times and increased service level.

  9. Use of a disposable circumcision suture device versus conventional circumcision: a systematic review and meta-analysis

    PubMed Central

    Huo, Zhong-Chao; Liu, Gang; Li, Xiao-Yan; Liu, Fei; Fan, Wen-Ju; Guan, Ru-Hua; Li, Pei-Feng; Mo, De-Yang; He, Yong-Zhi

    2017-01-01

    This systematic review assessed the safety and efficacy of the disposable circumcision suture device (DCSD) and conventional circumcision (CC) in the treatment of redundant prepuce and phimosis. Two independent reviewers conducted a literature search for randomized controlled trials (RCTs) using the DCSD and CC for the treatment of redundant prepuce or phimosis in China and abroad. Nine RCTs (1898 cases) were included. Compared with the CC group, the DCSD group had a shorter operative time (standardized mean difference [SMD] = −21.44; 95% confidence intervals [95% CIs] [−25.08, −17.79]; P < 0.00001), shorter wound healing time (SMD = −3.66; 95% CI [−5.46, −1.85]; P < 0.0001), less intraoperative blood loss (SMD = −9.64; 95% CI [−11.37, −7.90]; P < 0.00001), better cosmetic penile appearance (odds ratio [OR] =8.77; 95% CI [5.90, 13.02]; P < 0.00001), lower intraoperative pain score, lower 24-h postoperative pain score, lower incidence of infection, less incision edema, and fewer adverse events. There were no differences between the CC and DCSD groups in the incidences of dehiscence, or hematoma. The results of this meta-analysis indicate that the DCSD appears to be safer and more effective than CC. However, additional high-quality RCTs with larger study populations are needed. PMID:26975486

  10. Minimally invasive mitral valve surgery through right mini-thoracotomy: recommendations for good exposure, stable cardiopulmonary bypass, and secure myocardial protection.

    PubMed

    Ito, Toshiaki

    2015-07-01

    An apparent advantage of minimally invasive mitral surgery through right mini-thoracotomy is cosmetic appearance. Possible advantages of this procedure are a shorter ventilation time, shorter hospital stay, and less blood transfusion. With regard to hard endpoints, such as operative mortality, freedom from reoperation, or cardiac death, this method is reportedly equivalent, but not superior, to the standard median sternotomy technique. However, perfusion-related complications (e.g., stroke, vascular damage, and limb ischemia) tend to occur more frequently in minimally invasive technique than with the standard technique. In addition, valve repair through a small thoracotomy is technically demanding. Therefore, screening out patients who are not appropriate for performing minimally invasive surgery is the first step. Vascular disease and inadequate anatomy can be evaluated with contrast-enhanced computed tomography. Peripheral cannulation should be carefully performed, using transesophageal echocardiography guidance. Preoperative detailed planning of the valve repair process is desirable because every step is time-consuming in minimally invasive surgery. Three-dimensional echocardiography is a powerful tool for this purpose. For satisfactory exposure and detailed observation of the valve, a special left atrial retractor and high-definition endoscope are useful. Valve repair can be performed in minimally invasive surgery as long as cardiopulmonary bypass is stable and bloodless exposure of the valve is obtained.

  11. Effects of sugammadex on incidence of postoperative residual neuromuscular blockade: a randomized, controlled study.

    PubMed

    Brueckmann, B; Sasaki, N; Grobara, P; Li, M K; Woo, T; de Bie, J; Maktabi, M; Lee, J; Kwo, J; Pino, R; Sabouri, A S; McGovern, F; Staehr-Rye, A K; Eikermann, M

    2015-11-01

    This study aimed to investigate whether reversal of rocuronium-induced neuromuscular blockade with sugammadex reduced the incidence of residual blockade and facilitated operating room discharge readiness. Adult patients undergoing abdominal surgery received rocuronium, followed by randomized allocation to sugammadex (2 or 4 mg kg(-1)) or usual care (neostigmine/glycopyrrolate, dosing per usual care practice) for reversal of neuromuscular blockade. Timing of reversal agent administration was based on the providers' clinical judgement. Primary endpoint was the presence of residual neuromuscular blockade at PACU admission, defined as a train-of-four (TOF) ratio <0.9, using TOF-Watch® SX. Key secondary endpoint was time between reversal agent administration and operating room discharge-readiness; analysed with analysis of covariance. Of 154 patients randomized, 150 had a TOF value measured at PACU entry. Zero out of 74 sugammadex patients and 33 out of 76 (43.4%) usual care patients had TOF-Watch SX-assessed residual neuromuscular blockade at PACU admission (odds ratio 0.0, 95% CI [0-0.06], P<0.0001). Of these 33 usual care patients, 2 also had clinical evidence of partial paralysis. Time between reversal agent administration and operating room discharge-readiness was shorter for sugammadex vs usual care (14.7 vs. 18.6 min respectively; P=0.02). After abdominal surgery, sugammadex reversal eliminated residual neuromuscular blockade in the PACU, and shortened the time from start of study medication administration to the time the patient was ready for discharge from the operating room. Clinicaltrials.gov:NCT01479764. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Systematic off-pump coronary artery revascularization in multivessel disease: experience of three hundred cases.

    PubMed

    Cartier, R; Brann, S; Dagenais, F; Martineau, R; Couturier, A

    2000-02-01

    We sought to report our recent experience with off-pump coronary artery revascularization in multivessel disease. Between October 1996 and December 1998, 300 off-pump beating heart operations were performed at the Montreal Heart Institute by a single surgeon, representing 94% of all procedures undertaken during this same time frame (97% for 1998). This cohort of patients was compared with 1870 patients operated on with cardiopulmonary bypass from 1995 to 1996. Mean age, sex distribution, and preoperative risk factors were comparable for the two groups. On average, 2.92 +/- 0.8 and 2.84 +/- 0.6 grafts per patient were completed in the beating heart and cardiopulmonary bypass groups, respectively. A majority of patients (70%) had either a triple or quadruple bypass. Coronary anastomoses were achieved with myocardial mechanical stabilization and heart "verticalization." Ischemic time was shorter in the beating heart group (29.8 +/- 0.9 vs 45 +/- 0.4 minutes, P <.05). Similarly, the need for transfusion was significantly less in the beating heart group (beating heart operations, 34%; cardiopulmonary bypass, 66%; P <.005). Reduced use of postoperative intra-aortic counterpulsation, as well as a lower rise in creatine kinase MB isoenzyme, was observed in the beating heart group. Operative mortality rates (beating heart operations, 1. 3%; cardiopulmonary bypass, 2%) and perioperative myocardial infarction (beating heart operations, 3.6%; cardiopulmonary bypass, 4.2%) were comparable for the two groups. In a majority of patients, off-pump complete coronary artery revascularization is an acceptable alternative to conventional operations, yielding good results given progressive experience, rigorous technique, and adequate coronary artery stabilization.

  13. Evidence for decay in verbal short-term memory: a commentary on Berman, Jonides, and Lewis (2009).

    PubMed

    Campoy, Guillermo

    2012-07-01

    M. G. Berman, J. Jonides, and R. L. Lewis (2009) adapted the recent-probes task to investigate the causes of forgetting in short-term memory. In 7 experiments, they studied the persistence of memory traces by assessing the level of proactive interference generated by previous-trial items over a range of intertrial intervals. None of the experiments found a reduction in proactive interference over time, which they interpreted as evidence against time-based decay. However, it is possible that decay actually occurred over a shorter time period than was tested in this study, wherein the shortest decay interval was 3,300 ms. By reducing the time scale, the 2 experiments reported in the current commentary revealed a sharp decrease in proactive interference over time, with this reduction reaching a plateau in less than 3 s. This pattern suggests that decay operates in the early stages, whereas subsequent forgetting is likely to be due to interference. 2012 APA, all rights reserved

  14. Access-in-turn test architecture for low-power test application

    NASA Astrophysics Data System (ADS)

    Wang, Weizheng; Wang, JinCheng; Wang, Zengyun; Xiang, Lingyun

    2017-03-01

    This paper presents a novel access-in-turn test architecture (AIT-TA) for testing of very large scale integrated (VLSI) designs. In the proposed scheme, each scan cell in a chain receives test data from shift-in line in turn while pushing its test response to the shift-out line. It solves the power problem of conventional scan architecture to a great extent and suppresses significantly the switching activity during shift and capture operation with acceptable hardware overhead. Thus, it can help to implement the test at much higher operation frequencies resulting shorter test application time. The proposed test approach enhances the architecture of conventional scan flip-flops and backward compatible with existing test pattern generation and simulation techniques. Experimental results obtained for some larger ISCAS'89 and ITC'99 benchmark circuits illustrate effectiveness of the proposed low-power test application scheme.

  15. Applang - A DSL for specification of mobile applications for android platform based on textX

    NASA Astrophysics Data System (ADS)

    Kosanović, Milan; Dejanović, Igor; Milosavljević, Gordana

    2016-06-01

    Mobile platforms become a ubiquitous part of our daily lives thus making more pressure to software developers to develop more applications faster and with the support for different mobile operating systems. To foster the faster development of mobile services and applications and to support various mobile operating systems a new software development approaches must be undertaken. Domain-Specific Languages (DSL) are a viable approach that promise to solve a problem of target platform diversity as well as to facilitate rapid application development and shorter time-to-market. This paper presents Applang, a DSL for the specification of mobile applications for the Android platform, based on textX meta-language. The application is described using Applang DSL and the source code for a target platform is automatically generated by the provided code generator. The same application defined using single Applang source can be transformed to various targets with little or no manual modifications.

  16. Effects of Shuttle bay environment on UV sensitive photographic film - Instrumentation for Get-Away-Special

    NASA Technical Reports Server (NTRS)

    Kreplin, R. W.; Dohne, B.; Feldman, U.; Neupert, W. M.

    1984-01-01

    An account is given of a Get-Away-Special experiment flown on Space Shuttles 7 and 8 investigating the effect of the space environment on Shumann emulsions. Shumann emulsions, having low gelatin content and no protective gelatin overcoating, are useful detectors of ultraviolet radiation shorter than 2200 angstroms but are extremely sensitive to environmental conditions and handling. The instrument required no interface with the Shuttle. It was turned on by an aneroid switch at an altitude of 50,000 feet. After that, its operation was controlled completely by a CMOS digital controller. Each hour, two temperatures and one voltage were read and stored in a CMOS programmable read only memory. At intervals, valves were opened and closed to expose SO 652 film strips of three sensitivities to the cargo bay environment for various time periods. The design and operation of the instrument package is described.

  17. Is simple nephrectomy truly simple? Comparison with the radical alternative.

    PubMed

    Connolly, S S; O'Brien, M Frank; Kunni, I M; Phelan, E; Conroy, R; Thornhill, J A; Grainger, R

    2011-03-01

    The Oxford English dictionary defines the term "simple" as "easily done" and "uncomplicated". We tested the validity of this terminology in relation to open nephrectomy surgery. Retrospective review of 215 patients undergoing open, simple (n = 89) or radical (n = 126) nephrectomy in a single university-affiliated institution between 1998 and 2002. Operative time (OT), estimated blood loss (EBL), operative complications (OC) and length of stay in hospital (LOS) were analysed. Statistical analysis employed Fisher's exact test and Stata Release 8.2. Simple nephrectomy was associated with shorter OT (mean 126 vs. 144 min; p = 0.002), reduced EBL (mean 729 vs. 859 cc; p = 0.472), lower OC (9 vs. 17%; 0.087), and more brief LOS (mean 6 vs. 8 days; p < 0.001). All parameters suggest favourable outcome for the simple nephrectomy group, supporting the use of this terminology. This implies "simple" nephrectomies are truly easier to perform with less complication than their radical counterpart.

  18. Is the Abramson technique effective in pectus carinatum repair?

    PubMed

    Katrancioglu, Ozgur; Akkas, Yucel; Karadayi, Sule; Sahin, Ekber; Kaptanoğlu, Melih

    2018-01-01

    The minimally invasive pectus carinatum (PC) surgery described by Abramson has been performed in many centers. We have been using this technique since 2011. This article describes our experience with PC correction. Between 2011 and 2016, 32 patients at our institution underwent minimally invasive repair of a PC deformity. All patients presented with cosmetic complaints. The deformity involved the lower sternum (all had chondrogladiolar type PC), and three patients had asymmetrical deformities. All operations followed the principles defined by Abramson. Satisfactory esthetic results were achieved in our patients. The hospital stay averaged 5.3 days (range 4-7 days). The most common early complication was pneumothorax, and the most common late complication was wire suture breakage. The Abramson technique is an effective, minimally invasive procedure for PC with shorter operating and hospitalization times and low morbidity rates. Copyright © 2016. Published by Elsevier Taiwan.

  19. Effect of giant charge-transfer resonance σCT 109 barn on operation of magnetic fusion reactor below ``critical energy.''

    NASA Astrophysics Data System (ADS)

    Hester, Timothy; Maglich, Bogdan; Scott, Dan; Vaucher, Alexander

    2016-10-01

    Charge transfer (CT) reactivity was assumed to be negligible compared to ionization (IO) before Belfast measurements1-3 revealed the opposite: CT predominance over IO, σCT 109 b , σCT /σIO U 100 , below critical `atomic unit of velocity', vo = 2.2 ×108cms-1 , which is orbital velocity of e in H atom. Near vo, U = 1 , i.e. σCT σIO . Critical ion energy is T0 (lab) = k 25 M [ KeV ] = 200 KeV for [ ERR : md : MbegChr = 0 x 2329 , MendChr = 0 x 232 A , nParams = 1 ] = ion mass [ amu ] = 4 for DT mix ; k = 2 . ``Burnout'' pumping that requires U << 1 is inoperable in the U >> 1 regime whereas CT continually acts like compressor increasing operating vacuum pressure during neutral beam discharge to 10-3 Torr/0.3 s; this, in turn, sets upper limits to ion life-time against neutralization to τ =10-6 s. τ is 105 times shorter than thermalization time constant; hence plasma cannot be created. Lawson4 was unaware of CT resonance; his ``critical temperature'' (30 KeV for DT) should be replaced with T0.

  20. Mesophilic biomethanation and treatment of poultry waste-water using pilot scale UASB reactor.

    PubMed

    Atuanya, Ernest I; Aigbirior, Moses

    2002-07-01

    The feasibility of applying the up-flow anaerobic sludge blanket (UASB) treatment for poultry waste (faeces) water was examined. A continuous-flow UASB pilot scale reactor of 3.50 L capacity using mixed culture was operated for 95 days to assess the treatability of poultry waste-water and its methane production. The maximum chemical oxygen demand (COD) removed was found to be 78% when organic loading rate (OLR) was 2.9 kg COD m(-3) day(-1) at hydraulic retention times (HRT) of 13.2 hr. The average biogas recovery was 0.26 m3 CH4 kg COD with an average methane content of 57% at mean temperature of 30 degrees C. Data indicate more rapid methanogenesis with higher loading rates and shorter hydraulic retention times. At feed concentration of 4.8 kg COD m(-3) day(-1), anaerobic digestion was severely retarded at all hydraulic retention time tested. This complication in the reactor operations may be linked to build-up of colloidal solids often associated with poultry waste water and ammonia toxicity. Isolates from granular sludge and effluent were found to be facultative anaerobes most of which were Pseudomonas genera.

  1. Ultrasonic Measurement of Erosion/corrosion Rates in Industrial Piping Systems

    NASA Astrophysics Data System (ADS)

    Sinclair, A. N.; Safavi, V.; Honarvar, F.

    2011-06-01

    Industrial piping systems that carry aggressive corrosion or erosion agents may suffer from a gradual wall thickness reduction that eventually threatens pipe integrity. Thinning rates could be estimated from the very small change in wall thickness values measured by conventional ultrasound over a time span of at least a few months. However, measurements performed over shorter time spans would yield no useful information—minor signal distortions originating from grain noise and ultrasonic equipment imperfections prevent a meaningful estimate of the minuscule reduction in echo travel time. Using a Model-Based Estimation (MBE) technique, a signal processing scheme has been developed that enables the echo signals from the pipe wall to be separated from the noise. This was implemented in a laboratory experimental program, featuring accelerated erosion/corrosion on the inner wall of a test pipe. The result was a reduction in the uncertainty in the wall thinning rate by a factor of four. This improvement enables a more rapid response by system operators to a change in plant conditions that could pose a pipe integrity problem. It also enables a rapid evaluation of the effectiveness of new corrosion inhibiting agents under plant operating conditions.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, Raj, E-mail: rajdas@nhs.net, E-mail: raj.das@stgeorges.nhs.uk; Lucatelli, Pierleone, E-mail: pierleone.lucatelli@gmail.com; Wang, Haofan, E-mail: wwhhff123@gmail.com

    AimA clear understanding of operator experience is important in improving technical success whilst minimising patient risk undergoing endovascular procedures, and there is the need to ensure that trainees have the appropriate skills as primary operators. The aim of the study is to retrospectively analyse uterine artery embolisation (UAE) procedures performed by interventional radiology (IR) trainees at an IR training unit analysing fluoroscopy times and radiation dose as surrogate markers of technical skill.MethodsTen IR fellows were primary operator in 200 UAE procedures over a 5-year period. We compared fluoroscopy times, radiation dose and complications, after having them categorised according to threemore » groups: Group 1, initial five, Group 2, >5 procedures and Group 3, penultimate five UAE procedures. We documented factors that may affect screening time (number of vials employed and use of microcatheters).ResultsMean fluoroscopy time was 18.4 (±8.1), 17.3 (±9.0), 16.3 (±8.4) min in Groups 1, 2 and 3, respectively. There was no statistically significant difference between these groups (p > 0.05) with respect to fluoroscopy time or radiation dose. Analysis after correction for confounding factors showed no statistical significance (p > 0.05). All procedures were technically successful, and total complication rate was 4 %.ConclusionUAE was chosen as a highly standardised procedure followed by IR practitioners. Although there is a non-significant trend for shorter screening times with experience, technical success and safety were not compromised with appropriate Consultant supervision, which illustrates a safe construct for IR training. This is important and reassuring information for patients undergoing a procedure in a training unit.« less

  3. Efficacy of Chandelier Illumination for Combined Cataract Operation and Penetrating Keratoplasty

    PubMed Central

    Hariya, Takehiro; Uematsu, Megumi; Meguro, Yasuhiko; Kobayashi, Wataru; Nishida, Kohji; Nakazawa, Toru

    2015-01-01

    Purpose: The aim of this study was to describe a method for non–open-sky continuous curvilinear capsulorhexis (CCC) with chandelier retroillumination for penetrating keratoplasty triple procedure and report its effectiveness in decreasing intraoperative complications and enabling successful primary intraocular lens (IOL) insertion in patients with moderate or dense central corneal opacities. Methods: Seventeen eyes of 17 patients were enrolled in this study, divided into a chandelier group, including 7 eyes of 7 patients, and a nonchandelier group, including 10 eyes of 10 patients. In each group, time to achieve CCC (in seconds), open-sky time (in seconds), and operation time (in minutes) were measured, and the rates of successful CCC completion, rupture of the posterior capsule or zonule of Zinn, and successful IOL insertion were recorded. Results: CCC time was not significantly different in both groups. In the chandelier group, however, open-sky time and operation time were significantly shorter than in the nonchandelier group (1429 ± 67 vs. 2016 ± 354 seconds, and 90.4 ± 3.5 vs. 108.9 ± 10.3 minutes, respectively). In the chandelier group, the rate of successful CCC completion was significantly higher than in the nonchandelier group (86% vs. 30%). The rates of posterior capsule or zonule of Zinn rupture and successful IOL insertion were not significantly different (14% vs. 40%, 14% vs. 10%, and 86% vs. 70%, respectively). Conclusions: Non–open-sky CCC with chandelier illumination has many advantages for penetrating keratoplasty triple procedure compared with open-sky CCC without chandelier illumination. PMID:25564335

  4. Relationship Between Final Performance and Block Times with the Traditional and the New Starting Platforms with A Back Plate in International Swimming Championship 50-M and 100-M Freestyle Events

    PubMed Central

    Garcia-Hermoso, Antonio; Escalante, Yolanda; Arellano, Raul; Navarro, Fernando; Domínguez, Ana M.; Saavedra, Jose M.

    2013-01-01

    The purpose of this study was to investigate the association between block time and final performance for each sex in 50-m and 100-m individual freestyle, distinguishing between classification (1st to 3rd, 4th to 8th, 9th to 16th) and type of starting platform (old and new) in international competitions. Twenty-six international competitions covering a 13-year period (2000-2012) were analysed retrospectively. The data corresponded to a total of 1657 swimmers’ competition histories. A two-way ANOVA (sex x classification) was performed for each event and starting platform with the Bonferroni post-hoc test, and another two-way ANOVA for sex and starting platform (sex x starting platform). Pearson’s simple correlation coefficient was used to determine correlations between the block time and the final performance. Finally, a simple linear regression analysis was done between the final time and the block time for each sex and platform. The men had shorter starting block times than the women in both events and from both platforms. For 50-m event, medalists had shorter block times than semi- finalists with the old starting platforms. Block times were directly related to performance with the old starting platforms. With the new starting platforms, however, the relationship was inverse, notably in the women’s 50-m event. The block time was related for final performance in the men’s 50- m event with the old starting platform, but with the new platform it was critical only for the women’s 50-m event. Key Points The men had shorter block times than the women in both events and with both platforms. For both distances, the swimmers had shorter block times in their starts from the new starting platform with a back plate than with the old platform. For the 50-m event with the old starting platform, the medalists had shorter block times than the semi-finalists. The new starting platform block time was only determinant in the women’s 50-m event. In order to improve performance, specific training with the new platform with a back plate should be considered. PMID:24421729

  5. Potential sulfur-free pulping methods

    Treesearch

    Edward L. Springer; Rajai H. Atalla; Richard S. Reiner

    2002-01-01

    Lodgepole pine chips were pulped to Kappa numbers of about 70 using soda–AQ, soda–ODiMAQ, and kraft methods. At a catalyst level of 0.20% (oven-dry wood basis), cooking times for the soda cooks were significantly shorter than that for the kraft cook. The ODiMAQ catalyzed cooking time was much shorter than that of the AQ cook. It might be possible to replace the kraft...

  6. The effect of tonal changes on voice onset time in Mandarin esophageal speech.

    PubMed

    Liu, Hanjun; Ng, Manwa L; Wan, Mingxi; Wang, Supin; Zhang, Yi

    2008-03-01

    The present study investigated the effect of tonal changes on voice onset time (VOT) between normal laryngeal (NL) and superior esophageal (SE) speakers of Mandarin Chinese. VOT values were measured from the syllables /pha/, /tha/, and /kha/ produced at four tone levels by eight NL and seven SE speakers who were native speakers of Mandarin. Results indicated that Mandarin tones were associated with significantly different VOT values for NL speakers, in which high-falling tone was associated with significantly shorter VOT values than mid-rising tone and falling-rising tone. Regarding speaker group, SE speakers showed significantly shorter VOT values than NL speakers across all tone levels. This may be related to their use of pharyngoesophageal (PE) segment as another sound source. SE speakers appear to take a shorter time to start PE segment vibration compared to NL speakers using the vocal folds for vibration.

  7. [Curative effect analysis on closed reduction and external fixator under local anesthesia for the treatment of intertrochanteric fracture in elderly patients with high-risk].

    PubMed

    Wang, Zeng-ping; Liu, Lin; Xue, Wen; Zhou, Hui-ru; Song, Yu-xin; Cai, Li-yang; Cheng, Xian-tang; Qian, Yao-wen

    2016-06-01

    To explore clinical efficacy of closed reduction and external fixation under local anesthesia for the treatment of high-risk elderly patients with intertrochanteric fracture. From March 2013 to March 2015, 10 patients with intertrochanteric fractures treated with closing reduction and external fixator under local anesthesia were analyszed, including 4 males and 6 females, aged from 69 to 88 years old with an average of 75.2 years old. All fractures were caused by injury and classified to type I (5 cases), II (3 cases), and V (2 cases) according to Evans classification. According to American Society of Anesthesiologists (ASA), 6 cases were type III and 4 cases were type IV. Blood loss,operative time,hospital stays, postoperative complications, ambulation time and fracture healing time were observed, and Harris scoring were used to evaluate hip joint function. All patients were followed up from 3 to 23 months with an average of 13.1 months. One patient with chronic obstructive pulmonary disease died for non-operation reason at 4 months after operation, the other fractures were healed at stage I, the mean fracture healing time was 5.6 months. There were no coxa vara, lower limb venous thrombosis, loosen and remove of needle passage. The average operative time was 46 min, blood loss was (35.00 ± 8.46) ml without blood transfusion. One patient was occurred pulmonary infection and stent-tract infection on the 2 nd and 3 rd day after operation, and improved with active anti-infection and dressing change; the other patients gone to ground activity at 4.2 d after operation. The patients stayed hospital for 10.6 d on average. According to Harris scoring at final following-up, the total score was 83.42 ± 3.27, 3 cases obtained excellent results, 5 cases good and 1 case poor. Closed reduction and external fixation under local anesthesia in treating high-risk elderly patients with intertrochanteric fracture,which has advantages of shorter operative time, less blood loss, good recovery of postoperative function, is a safe, stable and economic method.

  8. How many hours do people sleep in Bangladesh? A country-representative survey.

    PubMed

    Yunus, Fakir M; Khan, Safayet; Akter, Tahera; Jhohura, Fatema T; Reja, Saifur; Islam, Akramul; Rahman, Mahfuzar

    2016-06-01

    This study investigated total sleep time in the Bangladeshi population and identified the proportion of the population at greater risk of developing chronic diseases due to inadequate sleep. Using a cross-sectional survey, total sleep time was captured and analysed in 3968 respondents aged between 6 and 106 years in 24 (of 64) districts in Bangladesh. Total sleep time was defined as the hours of total sleep in the previous 24 h. We used National Sleep Foundation (2015) guidelines to determine the recommended sleep hours in different age categories. Less or more than the recommended total sleep time (in hours) was considered 'shorter' and 'longer' sleep time, respectively. Linear and multinomial logistic regression models were used to determine the relationship between demographic variables and estimated risk of shorter and longer total sleep time. The mean (±standard deviation) total sleep time of children (6-13 years), teenagers (14-17 years), young adults and adults (18-64 years) and older adults (≥65 years) were 8.6 (±1.1), 8.1 (±1.0), 7.7 (±0.9) and 7.8 (±1.4) h, respectively, which were significantly different (P < 0.01). More than half of school-age children (55%) slept less than, and 28.2% of older adults slept longer than, recommended. Residents in all divisions (except Chittagong) in Bangladesh were less likely to sleep longer than in the Dhaka division. Rural populations had a 3.96× greater chance of sleeping for a shorter time than urban residents. The Bangladeshi population tends to sleep for longer and/or shorter times than their respective recommended sleep hours, which is detrimental to health. © 2016 European Sleep Research Society.

  9. Comparison of abdominal, vaginal, and laparoscopic hysterectomies in a tertiary care hospital in Turkey.

    PubMed

    Inal, Z O; Inal, H A

    2018-05-01

    The aim of this retrospective study was to assess and compare the clinical results of three hysterectomy techniques: abdominal hysterectomy (AH), vaginal hysterectomy (VH), and laparoscopic hysterectomy (LH). A total of 2163 patients having undergone AH (n = 1226), VH (n = 426), and LH (n = 511) procedures were analyzed. The mean age, body mass index (BMI), parity, uterus weight, operation time, blood loss, duration of hospitalization, analgesic needs, intra- and postoperative complications, and indications for hysterectomy were analyzed and compared. There were no differences between the groups with respect to the BMI, parity, and intra- or postoperative major and minor complications. The operation time was significantly shorter in the VH group than in the other two groups (p < 0.001), and the blood loss was significantly lower in the LH group than in the others (p < 0.001). The duration of hospitalization and analgesic needs were the shortest in the LH group (p < 0.001), while the uterus weight and previous intra-abdominal surgery rate were the lowest in the VH group (p < 0.001). Despite the fact that the LH exhibited a longer operation time than the VH, the LH was considered to be a safe and effective surgical procedure due to the lesser blood loss, hospital stay, and analgesic needs.

  10. Continuous-flow electrophoretic separator for biologicals

    NASA Technical Reports Server (NTRS)

    Mccreight, L. R.; Griffin, R. N.; Locker, R. J.

    1976-01-01

    In the near absence of gravity, a continuous-flow type of electrophoretic separator can be operated with a much thicker separation chamber than is possible under 1 g conditions. This should permit either better resolution or shorter separation time per unit of sample. An apparatus to perform experiments on sounding rockets is under development and will be described. The electrophoresis cell is 5 mm thick by 5 cm wide with 10 cm long electrodes. It is supplied with buffer, sample, and coolant at about 4 C through the use of a passive refrigerant system. UV sample detection and provision for recovery and cold storage of up to 50 sample fractions are now being added to the basic unit. A wide range of operating conditions are electronically programmable into the unit, even up to a short time before flight, and a further range of some parameters can be achieved by exchanging power supplies and by changing gears in the motor drive units of the pump. The preliminary results of some separation studies on various biological products using a commercially available electrophoretic separator are also presented.

  11. Pre-reconstruction of cervical-to-petrous internal carotid artery: An improved technique for treatment of vascular lesions involving internal carotid artery at the lateral skull base.

    PubMed

    Li, Fang-Da; Gao, Zhi-Qiang; Ren, Hua-Liang; Liu, Chang-Wei; Song, Xiao-Jun; Li, Yan-Feng; Zheng, Yue-Hong

    2016-04-01

    Reconstruction of the internal carotid artery (ICA) is an operative challenge for lesions involving the lateral skull base because of excessive blood loss, intraoperative cranial nerve injury, and difficulties in cerebral protection. Between January 2010 and October 2014, 9 patients with vascular lesions at the lateral skull base were treated with a "pre-reconstruction" technique, which means reconstruction of the ICA in advance of excising the lesions. All operations were technically successful with no mortality or strokes. The mean blood loss was 921 ± 210 mL. The mean total clamping time was 18 ± 5 minutes. Among the 5 patients without invasion of specific cranial nerves, no long-term sequelae occurred during the follow-up period ranging from 11 to 54 months. With less blood loss, slighter cranial nerve injuries, and shorter clamping time, the "pre-reconstruction" technique was safe and effective for the treatment of vascular lesions at the lateral skull base. © 2016 Wiley Periodicals, Inc. Head Neck 38: E1562-E1567, 2016. © 2016 Wiley Periodicals, Inc.

  12. [Laparoscopic radical cystectomy with enteric urinary diversion. Alternative to open cystectomy?].

    PubMed

    Lucan, M; Iacob, G; Lucan, V; Măgurean, O; Elec, F; Burghelea, C; Bărbos, A

    2005-01-01

    Radical cystectomy is the standard therapy for invasive bladder cancer, with best oncological results compared to any other therapeutic alternative. Even if laparoscopic radical cystectomy (LRC) is a well established surgical procedure, performing the urinary diversion completely intracorporeal, is still a challenge due to technical difficulties and associated complications. The aim of our study is to present the first series of LRC with ureterosigmoidostomy. Since May 2004 were performed 7 LRC (5 males and 2 females) (Gr. A). All cases were T2N0 clinical stage. These patients were compared with a retrospective group of 50 patients who underwent open procedure (Gr. B) in term of: operative time, blood loss, analgesic requirements, and hospital stay. LRC has a longer operative time but with statistically significant lower blood loss, less analgesia, and shorter hospital stay. The resection margins of the surgical specimens were tumor free at pathologic examination. Long-term follow-up is pending. On short-term, the results of laparoscopic radical cystectomy are encouraging. When significant experience in laparoscopic surgery is lacking, surgeons should exercise caution with completely intracorporeal urinary diversion.

  13. Evaluating Concrete Bridge Deck Performance

    DOT National Transportation Integrated Search

    2006-06-01

    Since the service life of concrete bridge decks designed by traditional procedures is often shorter than desired, : their ability to withstand constant and heavy use in a variety of operating environments is of major concern. In : this project, the r...

  14. The enhancement of rapidly quenched galaxies in distant clusters at 0.5 < z < 1.0

    NASA Astrophysics Data System (ADS)

    Socolovsky, Miguel; Almaini, Omar; Hatch, Nina A.; Wild, Vivienne; Maltby, David T.; Hartley, William G.; Simpson, Chris

    2018-05-01

    We investigate the relationship between environment and galaxy evolution in the redshift range 0.5 < z < 1.0. Galaxy overdensities are selected using a friends-of-friends algorithm, applied to deep photometric data in the Ultra-Deep Survey field. A study of the resulting stellar mass functions reveals clear differences between cluster and field environments, with a strong excess of low-mass rapidly quenched galaxies in cluster environments compared to the field. Cluster environments also show a corresponding deficit of young, low-mass star-forming galaxies, which show a sharp radial decline towards cluster centres. By comparing mass functions and radial distributions, we conclude that young star-forming galaxies are rapidly quenched as they enter overdense environments, becoming post-starburst galaxies before joining the red sequence. Our results also point to the existence of two environmental quenching pathways operating in galaxy clusters, operating on different time-scales. Fast quenching acts on galaxies with high specific star formation rates, operating on time-scales shorter than the cluster dynamical time (<1 Gyr). In contrast, slow quenching affects galaxies with moderate specific star formation rates, regardless of their stellar mass, and acts on longer time-scales (≳ 1 Gyr). Of the cluster galaxies in the stellar mass range 9.0 < log (M/M⊙) < 10.5 quenched during this epoch, we find that 73 per cent were transformed through fast quenching, while the remaining 27 per cent followed the slow quenching route.

  15. Vaginal sacrospinous colpopexy and laparoscopic sacral colpopexy for vaginal vault prolapse.

    PubMed

    Marcickiewicz, J; Kjöllesdal, M; Engh, M Ellström; Eklind, S; Axén, C; Brännström, M; Stjerndahl, J-H

    2007-01-01

    Vaginal sacrospinous colpopexy (VSC) and laparoscopic sacral colpopexy (LSC) both correct vault prolapse. The present study compares the perioperative course and long-term results of VSC and LSC. This retrospective study of post-hysterectomy vault prolapse involved 111 patients operated with either VSC (n=51) or LSC (n=60). The median time for the postoperative follow-up visit was 33.6 (range: 13-60) months for the LSC group and 38.4 (range: 7-108) months for the VSC group. Prolapse grade as well as the patient's satisfaction was recorded at the follow-up visit. Operation time was significantly shorter in the VSC group (median: 62 min) compared to the LSC group (median: 129 min). The rate of perioperative complications was low in both groups. There were 3 laparotomies in the LSC group, due to perioperative complications. The inpatients days were similar, with 3.7 days (1-18) and 4.0 days (2-21) in the VSC and the LSC group, respectively. Surgery for the recurrence of vault prolapse at any time before the follow-up visit did not occur in the VSC group, but occurred in 7 patients in the LSC group. At the follow-up visit, there was no recurrence of vault prolapse in either group. The subjective success rate was 82% in the VSC and 78% in the LSC group. This study indicates that VSC and LSC are two equally effective surgical procedures to correct vaginal vault prolapse, but the LSC technique requires a longer operating time.

  16. Coherent-Radiation Spectroscopy of Few-Femtosecond Electron Bunches Using a Middle-Infrared Prism Spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, T. J.; Behrens, C.; Ding, Y.

    2013-10-28

    Modern, high-brightness electron beams such as those from plasma wakefield accelerators and free-electron laser linacs continue the drive to ever-shorter bunch durations. In low-charge operation ( ~ 20 pC ), bunches shorter than 10 fs are reported at the Linac Coherent Light Source (LCLS). Though suffering from a loss of phase information, spectral diagnostics remain appealing as compact, low-cost bunch duration monitors suitable for deployment in beam dynamics studies and operations instrumentation. Progress in middle-infrared (MIR) imaging has led to the development of a single-shot, MIR prism spectrometer to characterize the corresponding LCLS coherent beam radiation power spectrum for few-femtosecondmore » scale bunch length monitoring. In this Letter, we report on the spectrometer installation as well as the temporal reconstruction of 3 to 60 fs-long LCLS electron bunch profiles using single-shot coherent transition radiation spectra.« less

  17. Serum Iron Level Is Associated with Time to Antibiotics in Cystic Fibrosis.

    PubMed

    Gifford, Alex H; Dorman, Dana B; Moulton, Lisa A; Helm, Jennifer E; Griffin, Mary M; MacKenzie, Todd A

    2015-12-01

    Serum levels of hepcidin-25, a peptide hormone that reduces blood iron content, are elevated when patients with cystic fibrosis (CF) develop pulmonary exacerbation (PEx). Because hepcidin-25 is unavailable as a clinical laboratory test, we questioned whether a one-time serum iron level was associated with the subsequent number of days until PEx, as defined by the need to receive systemic antibiotics (ABX) for health deterioration. Clinical, biochemical, and microbiological parameters were simultaneously checked in 54 adults with CF. Charts were reviewed to determine when they first experienced a PEx after these parameters were assessed. Time to ABX was compared in subgroups with and without specific attributes. Multivariate linear regression was used to identify parameters that significantly explained variation in time to ABX. In univariate analyses, time to ABX was significantly shorter in subjects with Aspergillus-positive sputum cultures and CF-related diabetes. Multivariate linear regression models demonstrated that shorter time to ABX was associated with younger age, lower serum iron level, and Aspergillus sputum culture positivity. Serum iron, age, and Aspergillus sputum culture positivity are factors associated with shorter time to subsequent PEx in CF adults. © 2015 Wiley Periodicals, Inc.

  18. Anterolateral minithoracotomy versus median sternotomy for mitral valve disease: a meta-analysis.

    PubMed

    Ding, Chao; Jiang, Da-ming; Tao, Kai-yu; Duan, Qun-jun; Li, Jie; Kong, Min-jian; Shen, Zhong-hua; Dong, Ai-qiang

    2014-06-01

    Mitral valve disease tends to be treated with anterolateral minithoracotomy (ALMT) rather than median sternotomy (MS), as ALMT uses progressively smaller incisions to promote better cosmetic outcomes. This meta-analysis quantifies the effects of ALMT on surgical parameters and post-operative outcomes compared with MS. One randomized controlled study and four case-control studies, published in English from January 1996 to January 2013, were identified and evaluated. ALMT showed a significantly longer cardiopulmonary bypass time (P=0.001) and aortic cross-clamp time (P=0.05) compared with MS. However, the benefits of ALMT were evident as demonstrated by a shorter length of hospital stay (P<0.00001). According to operative complications, the onset of new arrhythmias following ALMT decreased significantly as compared with MS (P=0.05); however, the incidence of peri-operative mortality (P=0.62), re-operation for bleeding (P=0.37), neurologic events (P=0.77), myocardial infarction (P=0.84), gastrointestinal complications (P=0.89), and renal insufficiency (P=0.67) were similar to these of MS. Long-term follow-up data were also examined, and revealed equivalent survival and freedom from mitral valve events. Current clinical data suggest that ALMT is a safe and effective alternative to the conventional approach and is associated with better short-term outcomes and a trend towards longer survival.

  19. Anterolateral minithoracotomy versus median sternotomy for mitral valve disease: a meta-analysis

    PubMed Central

    Ding, Chao; Jiang, Da-ming; Tao, Kai-yu; Duan, Qun-jun; Li, Jie; Kong, Min-jian; Shen, Zhong-hua; Dong, Ai-qiang

    2014-01-01

    Objective: Mitral valve disease tends to be treated with anterolateral minithoracotomy (ALMT) rather than median sternotomy (MS), as ALMT uses progressively smaller incisions to promote better cosmetic outcomes. This meta-analysis quantifies the effects of ALMT on surgical parameters and post-operative outcomes compared with MS. Methods: One randomized controlled study and four case-control studies, published in English from January 1996 to January 2013, were identified and evaluated. Results: ALMT showed a significantly longer cardiopulmonary bypass time (P=0.001) and aortic cross-clamp time (P=0.05) compared with MS. However, the benefits of ALMT were evident as demonstrated by a shorter length of hospital stay (P<0.00001). According to operative complications, the onset of new arrhythmias following ALMT decreased significantly as compared with MS (P=0.05); however, the incidence of peri-operative mortality (P=0.62), re-operation for bleeding (P=0.37), neurologic events (P=0.77), myocardial infarction (P=0.84), gastrointestinal complications (P=0.89), and renal insufficiency (P=0.67) were similar to these of MS. Long-term follow-up data were also examined, and revealed equivalent survival and freedom from mitral valve events. Conclusions: Current clinical data suggest that ALMT is a safe and effective alternative to the conventional approach and is associated with better short-term outcomes and a trend towards longer survival. PMID:24903989

  20. [Innovation of characteristic medicinal cupping devices].

    PubMed

    Li, Jianping; Zhang, Hui; Yang, Jianmei; Xu, Xinchun; Niu, Yanxia; Cai, Jun

    2015-08-01

    To compare the differences in the characteristic medicinal cupping therapy between the traditional cupping device and the innovated cupping device. Fifty patients of neck and low back pain were selected. The self-comparison was adopted. The cupping therapy was applied to the acupoints located on the left or right side with the traditional cupping device and the innovated cupping device. The cupping sites were centered at bilateral Quyuan (SI 13) and Dachangshu (BL 25). The cups were retained for 10 min. The traditional cupping device was the glass with smooth border, 100mL. The innovated cupping device was the vacuum-sucking cup. The operative time, medicinal leakage, comfort and cupping marks were observed for the two different cupping devices. The operative time with the innovated medicinal cupping device was shorter obviously compared with the traditional one at Quyuan (SI 13) and Dachangshu (BL 25, both P<0. 05). The comfort with the innovated medicinal cupping device was remarkably improved as compared with the traditional one at the two acupoints (both P<0. 05). The medicinal leakage was similar between the two different devices during the cupping operation (both P>0. 05). The cupping marks with the innovated medicinal cupping device were much deeper than those with the traditional one after cupping therapy. The innovated cupping device is more convenent and comfortable in operation during the characteristic medicinal cupping therapy.

  1. Challenges of using new and repurposed drugs for the treatment of multidrug-resistant tuberculosis in children.

    PubMed

    Schaaf, H Simon; Garcia-Prats, Anthony J; McKenna, Lindsay; Seddon, James A

    2018-03-01

    New and repurposed antituberculosis drugs are urgently needed to more safely and effectively treat multidrug-resistant (MDR) tuberculosis (TB) in children. Multiple challenges limit timely access to new MDR-TB treatments in children. Areas covered: Diagnosis of MDR-TB in children remains a barrier, with few children with MDR-TB diagnosed and treated. Other barriers to timely access to new and repurposed drugs are discussed, and include delayed initiation of paediatric trials, limited funding for paediatric drug development, fragmented regulatory systems and operational challenges. The status of access to current repurposed and novel drugs is presented. Expert commentary: More timely initiation of paediatric trials is needed and paediatric work should happen and be funded in parallel with each phase of adult trials. Better quality data, increased regulator resources and expertise, harmonization of regulatory requirements across borders/organisations and registration fee waivers would improve registration timelines. Improved diagnosis, recording and reporting will establish better demand. Improved systems for procurement and supply chain management would reduce in-country operational barriers to getting medications to children. The challenges must be addressed to ensure timely and equitable access to new drugs and regimens that are urgently needed for effective, safe and shorter treatment of children with MDR-TB.

  2. Feasibility of UltraFast Doppler in Post-operative Evaluation of Hepatic Artery in Recipients following Liver Transplantation.

    PubMed

    Kim, Se-Young; Kim, Kyoung Won; Choi, Sang Hyun; Kwon, Jae Hyun; Song, Gi-Won; Kwon, Heon-Ju; Yun, Young Ju; Lee, Jeongjin; Lee, Sung-Gyu

    2017-11-01

    To determine the feasibility of using UltraFast Doppler in post-operative evaluation of the hepatic artery (HA) after liver transplantation (LT), we evaluated 283 simultaneous conventional and UltraFast Doppler sessions in 126 recipients over a 2-mo period after LT, using an Aixplorer scanner The Doppler indexes of the HA (peak systolic velocity [PSV], end-diastolic velocity [EDV], resistive index [RI] and systolic acceleration time [SAT]) by retrospective analysis of retrieved waves from UltraFast Doppler clips were compared with those obtained by conventional spectral Doppler. Correlation, performance in diagnosing the pathologic wave, examination time and reproducibility were evaluated. The PSV, EDV, RI and SAT of spectral and UltraFast Doppler measurements exhibited excellent correlation with favorable diagnostic performance. During the bedside examination, the mean time spent for UltraFast clip storing was significantly shorter than that for conventional Doppler US measurements. Both conventional and UltraFast Doppler exhibited good to excellent inter-analysis consistency. In conclusion, compared with conventional spectral Doppler, UltraFast Doppler values correlated excellently and yielded acceptable pathologic wave diagnostic performance with reduced examination time at the bedside and excellent reproducibility. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  3. Transurethral plasmakinetic resection of the prostate is a reliable minimal invasive technique for benign prostate hyperplasia: a meta-analysis of randomized controlled trials.

    PubMed

    Wang, Kai; Li, Yao; Teng, Jing-Fei; Zhou, Hai-Yong; Xu, Dan-Feng; Fan, Yi

    2015-01-01

    To evaluate the efficacy and safety of plasmakinetic resection of the prostate (PKRP) versus transurethral resection of the prostate (TURP) for the treatment of patients with benign prostate hyperplasia (BPH), a meta-analysis of randomized controlled trials was carried out. We searched PubMed, Embase, Web of Science and the Cochrane Library. The pooled estimates of maximum flow rate, International Prostate Symptom Score, operation time, catheterization time, irrigated volume, hospital stay, transurethral resection syndrome, transfusion, clot retention, urinary retention and urinary stricture were assessed. There was no notable difference in International Prostate Symptom Score between TURP and PKRP groups during the 1-month, 3 months, 6 months and 12 months follow-up period, while the pooled Q max at 1-month favored PKRP group. PKRP group was related to a lower risk rate of transurethral resection syndrome, transfusion and clot retention, and the catheterization time and operation time were also shorter than that of TURP. The irrigated volume, length of hospital stay, urinary retention and urinary stricture rate were similar between groups. In conclusion, our study suggests that the PKRP is a reliable minimal invasive technique and may anticipatorily prove to be an alternative electrosurgical procedure for the treatment of BPH.

  4. Anesthetic efficacy of ketamine-diazepam, ketamine-xylazine, and ketamine-acepromazine in Caspian Pond turtles (Mauremys caspica).

    PubMed

    Adel, Milad; Sadegh, Amin Bigham; Arizza, Vincenzo; Abbasi, Hossein; Inguglia, Luigi; Saravi, Hasan Nasrollahzadeh

    2017-01-01

    The objective of this study was to assess the efficacy of different anesthetic drug combinations on the Caspian Pond turtles ( Mauremys caspica ). Three groups of the Caspian Pond turtles ( n = 6) were anesthetized with three different drug combinations. Initially, a pilot study was conducted to determine the best drug doses for the anesthetization of the turtles, and according to these results, ketamine-diazepam (120 mg/kg ketamine hydrochloride [5%] and 2 mg/kg diazepam [5%]), ketamine-acepromazine (120 mg/kg ketamine hydrochloride [5%] and 1 mg/kg acepromazine [1%]), and ketamine-xylazine (120 mg/kg ketamine hydrochloride [5%] and 1 mg/kg xylazine [2%]) were injected intramuscularly. The onset times of anesthetization and the recovery time were measured. Statistical analysis of the data was performed using one-way analysis of variance followed by t -tests, and P < 0.05 was considered statistically significant. There were statistically significant differences in the mean of the onset times of anesthesia and recovery time among the three drug combinations depending on the treatment used. The onset of anesthesia of the animals treated with the ketamine-diazepam combination was 60% and 42% shorter, for male and female turtles, respectively, compared to that obtained with the ketamine-acepromazine combination and 64% (male turtles) and 50% (female turtles) shorter than that obtained with the ketamine-xylazine combination. Further, the recovery time, in male turtles, was 17% shorter in animals treated with the first drug combination than those treated with the ketamine-acepromazine combination and 37% shorter than those treated with the ketamine-xylazine combination. The recovery time, in female turtles, did not seem to be significantly different among treatments. The study showed that the ketamine-diazepam drug combination is the anesthetic combination with the fastest onset time and shortest recovery time.

  5. Role of recoverin in rod photoreceptor light adaptation.

    PubMed

    Morshedian, Ala; Woodruff, Michael L; Fain, Gordon L

    2018-04-15

    Recoverin is a small molecular-weight, calcium-binding protein in rod outer segments that can modulate the rate of rhodopsin phosphorylation. We describe two additional and perhaps more important functions during photoreceptor light adaptation. Recoverin influences the rate of change of adaptation. In wild-type rods, sensitivity and response integration time adapt with similar time constants of 150-200 ms. In Rv-/- rods lacking recoverin, sensitivity declines faster and integration time is already shorter and not significantly altered. During steady light exposure, rod circulating current slowly increases during a time course of tens of seconds, gradually extending the operating range of the rod. In Rv-/- rods, this mechanism is deleted, steady-state currents are already larger and rods saturate at brighter intensities. We propose that recoverin modulates spontaneous and light-activated phophodiesterase-6, the phototransduction effector enzyme, to increase sensitivity in dim light but improve responsiveness to change in brighter illumination. Recoverin is a small molecular-weight, calcium-binding protein in rod outer segments that binds to G-protein receptor kinase 1 and can alter the rate of rhodopsin phosphorylation. A change in phosphorylation should change the lifetime of light-activated rhodopsin and the gain of phototransduction, but deletion of recoverin has little effect on the sensitivity of rods either in the dark or in dim-to-moderate background light. We describe two additional functions perhaps of greater physiological significance. (i) When the ambient intensity increases, sensitivity and integration time decrease in wild-type (WT) rods with similar time constants of 150-200 ms. Recoverin is part of the mechanism controlling this process because, in Rv-/- rods lacking recoverin, sensitivity declines more rapidly and integration time is already shorter and not further altered. (ii) During steady light exposure, WT rod circulating current slowly increases during a time course of tens of seconds, gradually extending the operating range of the rod. In Rv-/- rods, this mechanism is also deleted, steady-state currents are already larger and rods saturate at brighter intensities. We argue that neither (i) nor (ii) can be caused by modulation of rhodopsin phosphorylation but may instead be produced by direct modulation of phophodiesterase-6 (PDE6), the phototransduction effector enzyme. We propose that recoverin in dark-adapted rods keeps the integration time long and the spontaneous PDE6 rate relatively high to improve sensitivity. In background light, the integration time is decreased to facilitate detection of change and motion and the spontaneous PDE6 rate decreases to augment the rod working range. © 2018 The Authors. The Journal of Physiology © 2018 The Physiological Society.

  6. [Clinical study of tissue-selecting therapy in the treatment of mixed hemorrhoids: a single-blind randomized controlled trail].

    PubMed

    He, Hongyan; He, Ping; Liu, Ning

    2014-06-01

    To evaluate the clinical efficacy and safety of tissue-selecting therapy (TST) in treatment of mixed hemorrhoids. A single-blind randomized study was carried out. A total of 120 patients with mixed hemorrhoids from January to December 2012 were prospectively enrolled in the study and equally divided into two groups, TST group and procedure for prolapse and hemorrhoids(PPH) group. Surgical data, efficacy and postoperative complications were compared between the two groups. As compared to PPH group, patients in TST group had shorter operation time [(15.9±5.18) min vs. (22.6±7.1) min, P<0.05], lower scores of rectal urgency (0.5±0.2 vs. 1.5±1.4, P<0.05), and shorter hospital stay [(11.2±3.7) d vs. (14.8±3.7) d, P<0.05]. No anastomotic stricture case was found in TST group, while 11 cases(18.3%) developed anastomotic stricture in PPH group. There were no significant differences in effective rate and pain score of first defecation between the two groups. TST is reliable and safe for mixed hemorrhoids with the advantage of simple, rapid recovery and less complications.

  7. Influence of an anomalous dimension effect on thermal instability in amorphous-InGaZnO thin-film transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Kuan-Hsien; Chou, Wu-Ching, E-mail: tcchang3708@gmail.com, E-mail: wuchingchou@mail.nctu.edu.tw; Chang, Ting-Chang, E-mail: tcchang3708@gmail.com, E-mail: wuchingchou@mail.nctu.edu.tw

    2014-10-21

    This paper investigates abnormal dimension-dependent thermal instability in amorphous indium-gallium-zinc-oxide (a-IGZO) thin-film transistors. Device dimension should theoretically have no effects on threshold voltage, except for in short channel devices. Unlike short channel drain-induced source barrier lowering effect, threshold voltage increases with increasing drain voltage. Furthermore, for devices with either a relatively large channel width or a short channel length, the output drain current decreases instead of saturating with an increase in drain voltage. Moreover, the wider the channel and the shorter the channel length, the larger the threshold voltage and output on-state current degradation that is observed. Because of themore » surrounding oxide and other thermal insulating material and the low thermal conductivity of the IGZO layer, the self-heating effect will be pronounced in wider/shorter channel length devices and those with a larger operating drain bias. To further clarify the physical mechanism, fast I{sub D}-V{sub G} and modulated peak/base pulse time I{sub D}-V{sub D} measurements are utilized to demonstrate the self-heating induced anomalous dimension-dependent threshold voltage variation and on-state current degradation.« less

  8. A Surgery-first approach in surgical-orthodontic treatment of mandibular prognathism--a case report.

    PubMed

    Yu, Chung-Chih; Chen, Po-Hsun; Liou, Eric J W; Huang, Chiung-Shing; Chen, Yu-Ray

    2010-01-01

    The conventional approach in orthodontic surgery treatment of dentofacial anomalies requires a varied period of pre-surgical orthodontic treatment. This presurgical period is considered to be important for adequate surgical treatment and stable results. This period is usually long bothersome for patients because dental decompensation is required and there is consequent deterioration of aesthetics and function, especially in cases of skeletal Class III occlusion. At Chang Gung Craniofacial Center, a surgery-first approach (SFA), i.e. minimal pre-surgical orthodontics, is one of the treatment choices for Class III patients. In this report, we present a 19-year-old man with mandibular prognathism, an anterior open bite and severe dental crowding treated with SFA. The patient received orthognathic surgery a week after bracing of the teeth. The operation and recovery were uneventful as well as the following orthodontic treatment. The total treatment time was only four months, much shorter than with the conventional approach. The patient benefitted from immediate improvement of the facial profile after surgery, and a much shorter total treatment, and the results were not compromised. We believe in selected cases, SFA is a good and effective treatment alternative.

  9. Robotic assisted gastrectomy compared with open resection: a case-matched study.

    PubMed

    Caruso, Riccardo; Vicente, Emilio; Quijano, Yolanda; Ielpo, Benedetto; Duran, Hipolito; Diaz, Eduardo; Fabra, Isabel; Ferri, Valentina

    2018-05-04

    In recent years, increasingly sophisticated tools have allowed for more complex robotic surgery. Robotic gastrectomy, however, is adopted in only a few selected centers. The goals of this study were to examine the adoption of robotic gastrectomy and to compare outcomes between open and robotic gastric resections. This is a case-matched analysis of patients who underwent robotic and open gastric resection performed at Sanchinarro University Hospital, Madrid from November 2011 to February 2017. Patient data were obtained retrospectively. Clinicopathologic characteristics and perioperative and postoperative outcomes were recorded and analyzed. Two groups of demographically similar patients were analyzed: the robotic group (n = 20) and the open surgery group (n = 19). The patient characteristics of the two groups have been compared. Robotic resection resulted in less blood loss, shorter postoperative hospital stay, and a longer operating time. The two groups had similar complication rates. Pathological data were similar for both procedures. Robotic gastrectomy for locally advanced gastric carcinoma is safe, and long-term outcomes are comparable to those patients who underwent open resection. Robotic gastrectomy resulted in a shorter hospital stay, less blood loss and morbidity comparable with the outcomes of open gastrectomy.

  10. Facial palsy in children: emergency department management and outcome.

    PubMed

    Wang, Cheng-Hsien; Chang, Yu-Che; Shih, Hong-Mo; Chen, Chun-Yu; Chen, Jih-Chang

    2010-02-01

    To describe the characteristics of children who present to an emergency department (ED) with facial palsy and determine the association of outcome with etiology, degree of initial paralysis, and ED management. This was a retrospective cohort study of children who presented to an ED with facial nerve paralysis (FNP). There were 85 patients with a mean age of 8.0 (SD, 6.1) years; 60% (n = 51) of the patients were male, and 65.9% (n = 56) were admitted to the hospital. Bell palsy (50.6%) was the most common etiology followed by infectious (22.4%), traumatic (16.5%), congenital (7.1%), and neoplastic etiologies (3.5%). Patients with Bell palsy had shorter recovery times (P = 0.049), and traumatic cases required a longer time for recovery (P = 0.016). Acute otitis media (AOM)-related pediatric FNP had shorter recovery times than non-AOM-related cases (P = 0.005) in infectious group. Patients given steroid therapy did not have a shorter recovery time (P = 0.237) or a better recovery (P = 0.269). There was no difference in recovery rate of pediatric patients with Bell palsy between hospitalization or not (P = 0.952). Bell palsy, infection, and trauma were most common etiologies of pediatric FNP. Recovery times were shorter in pediatric patients with Bell palsy and AOM-related FNP, whereas recovery took longer in traumatic cases. Steroid therapy did not seem beneficial for pediatric FNP. Hospitalization is not indicated for pediatric patients with Bell palsy.

  11. Reducing elective general surgery cancellations at a Canadian hospital

    PubMed Central

    Azari-Rad, Solmaz; Yontef, Alanna L.; Aleman, Dionne M.; Urbach, David R.

    2013-01-01

    Background In Canadian hospitals, which are typically financed by global annual budgets, overuse of operating rooms is a financial risk that is frequently managed by cancelling elective surgical procedures. It is uncertain how different scheduling rules affect the rate of elective surgery cancellations. Methods We used discrete event simulation modelling to represent perioperative processes at a hospital in Toronto, Canada. We tested the effects of the following 3 scenarios on the number of surgical cancellations: scheduling surgeons’ operating days based on their patients’ average length of stay in hospital, sequencing surgical procedures by average duration and variance, and increasing the number of post-surgical ward beds. Results The number of elective cancellations was reduced by scheduling surgeons whose patients had shorter average lengths of stay in hospital earlier in the week, sequencing shorter surgeries and those with less variance in duration earlier in the day, and by adding up to 2 additional beds to the postsurgical ward. Conclusion Discrete event simulation modelling can be used to develop strategies for improving efficiency in operating rooms. PMID:23351498

  12. Atlas and feature based 3D pathway visualization enhancement for skull base pre-operative fast planning from head CT

    NASA Astrophysics Data System (ADS)

    Aghdasi, Nava; Li, Yangming; Berens, Angelique; Moe, Kris S.; Bly, Randall A.; Hannaford, Blake

    2015-03-01

    Minimally invasive neuroendoscopic surgery provides an alternative to open craniotomy for many skull base lesions. These techniques provides a great benefit to the patient through shorter ICU stays, decreased post-operative pain and quicker return to baseline function. However, density of critical neurovascular structures at the skull base makes planning for these procedures highly complex. Furthermore, additional surgical portals are often used to improve visualization and instrument access, which adds to the complexity of pre-operative planning. Surgical approach planning is currently limited and typically involves review of 2D axial, coronal, and sagittal CT and MRI images. In addition, skull base surgeons manually change the visualization effect to review all possible approaches to the target lesion and achieve an optimal surgical plan. This cumbersome process relies heavily on surgeon experience and it does not allow for 3D visualization. In this paper, we describe a rapid pre-operative planning system for skull base surgery using the following two novel concepts: importance-based highlight and mobile portal. With this innovation, critical areas in the 3D CT model are highlighted based on segmentation results. Mobile portals allow surgeons to review multiple potential entry portals in real-time with improved visualization of critical structures located inside the pathway. To achieve this we used the following methods: (1) novel bone-only atlases were manually generated, (2) orbits and the center of the skull serve as features to quickly pre-align the patient's scan with the atlas, (3) deformable registration technique was used for fine alignment, (4) surgical importance was assigned to each voxel according to a surgical dictionary, and (5) pre-defined transfer function was applied to the processed data to highlight important structures. The proposed idea was fully implemented as independent planning software and additional data are used for verification and validation. The experimental results show: (1) the proposed methods provided greatly improved planning efficiency while optimal surgical plans were successfully achieved, (2) the proposed methods successfully highlighted important structures and facilitated planning, (3) the proposed methods require shorter processing time than classical segmentation algorithms, and (4) these methods can be used to improve surgical safety for surgical robots.

  13. Long Term Outcomes of Laparoscopic and Open Modified Lich-Gregoir Reimplantation in Adults: A multicentric comparative study.

    PubMed

    Atar, Arda; Eksi, Mithat; Güler, Ahmet Faysal; Tuncer, Murat; Akkas, Fatih; Tugcu, Volkan

    2017-01-01

    Obstructive ureteral pathologies in adult patients are most commonly due to ureteral strictures and secondary to surgical interventions. In this study, we aimed to compare open and laparoscopic modified Lich-Gregoir ureteral reimplantation with regards to outcomes in benign ureteral pathologies in adult patients. Between December 2008 and December 2014, 32 open cases and 29 laparoscopic cases were performed as per the data retrieved from surgical databases. All laparoscopic procedures were performed in Bakirkoy Dr. Sadi Konuk Training and Research Hospital(BEAH) and all open ureteral reimplantation procedures in Kartal Dr Lutfi Kirdar Training and Research Hospital(KEAH) and Okmeydani Training and Research Hospital(OEAH). The mean operation time was significantly lower in the group of patients operated with open group (142.5 minutes versus 188.9 minutes; P< 0.0001). The mean duration of follow-up was longer in the laparoscopy group (31 versus 28 months; p< 0.0001). The mean amount of operation associated blood loss was significantly lower in patients operated laparoscopically (93.7 mL versus 214 mL; P< 0.0001). The mean VAS score obtained six hours after surgery was 6.6 ± 0.8 in open group, and 5.8 ± 0.7 in laparoscopic group (p=0.0004). The mean VAS scores measured at post-operative day 1 was 4.5 ± 0.7 in open group and 3.7 ± 0.9 in laparoscopy group. Time required to achieve the pre-operative capability of daily activities was significantly longer in open group (15 ± 1.4 days vs 11 ± 1.4 days; p< 0.0001). Despite open techniques provide shorter operation time and laparoscopic techniques require long learning curve, we think that laparoscopic techniques are superior to open ones since that they provide a better post-operative comfort and are better tolerated in terms of complications.

  14. Long Term Outcomes of Laparoscopic and Open Modified Lich-Gregoir Reimplantation in Adults: A multicentric comparative study

    PubMed Central

    Atar, Arda; Eksi, Mithat; Güler, Ahmet Faysal; Tuncer, Murat; Akkas, Fatih; Tugcu, Volkan

    2017-01-01

    Background & Objective: Obstructive ureteral pathologies in adult patients are most commonly due to ureteral strictures and secondary to surgical interventions. In this study, we aimed to compare open and laparoscopic modified Lich-Gregoir ureteral reimplantation with regards to outcomes in benign ureteral pathologies in adult patients. Methods: Between December 2008 and December 2014, 32 open cases and 29 laparoscopic cases were performed as per the data retrieved from surgical databases. All laparoscopic procedures were performed in Bakirkoy Dr. Sadi Konuk Training and Research Hospital(BEAH) and all open ureteral reimplantation procedures in Kartal Dr Lutfi Kirdar Training and Research Hospital(KEAH) and Okmeydani Training and Research Hospital(OEAH). Results: The mean operation time was significantly lower in the group of patients operated with open group (142.5 minutes versus 188.9 minutes; P< 0.0001). The mean duration of follow-up was longer in the laparoscopy group (31 versus 28 months; p< 0.0001). The mean amount of operation associated blood loss was significantly lower in patients operated laparoscopically (93.7 mL versus 214 mL; P< 0.0001). The mean VAS score obtained six hours after surgery was 6.6 ± 0.8 in open group, and 5.8 ± 0.7 in laparoscopic group (p=0.0004). The mean VAS scores measured at post-operative day 1 was 4.5 ± 0.7 in open group and 3.7 ± 0.9 in laparoscopy group. Time required to achieve the pre-operative capability of daily activities was significantly longer in open group (15 ± 1.4 days vs 11 ± 1.4 days; p< 0.0001). Conclusion: Despite open techniques provide shorter operation time and laparoscopic techniques require long learning curve, we think that laparoscopic techniques are superior to open ones since that they provide a better post-operative comfort and are better tolerated in terms of complications. PMID:29067040

  15. Behavioral regulation of gravity - Schedule effects under escape-avoidance procedures

    NASA Technical Reports Server (NTRS)

    Clark, F. C.; Lange, K. O.; Belleville, R. E.

    1973-01-01

    Squirrel monkeys were restrained in a centrifuge capsule and trained to escape and avoid increases in artificial gravity. During escape-avoidance, lever responses reduced centrifugally simulated gravity or postponed scheduled increases. The effect of variation in the interval of postponement (equal to the duration of decrease produced by escape responses) was studied under a multiple schedule of four components. Three components were gravity escape-avoidance with postponement times of 20, 40, and 60 sec. The fourth component was extinction. Each component was associated with a different auditory stimulus. Rate of responding decreased with increasing postponement time and higher mean g-levels occurred at shorter intervals of postponement. Effects of the schedule parameter on response rate and mean g-level were similar to effects of the schedule on free-operant avoidance and on titration behavior maintained by shock.

  16. Optical clearing for luminal organ imaging with ultrahigh-resolution optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Liang, Yanmei; Yuan, Wu; Mavadia-Shukla, Jessica; Li, Xingde

    2016-08-01

    The imaging depth of optical coherence tomography (OCT) in highly scattering biological tissues (such as luminal organs) is limited, particularly for OCT operating at shorter wavelength regions (such as around 800 nm). For the first time, the optical clearing effect of the mixture of liquid paraffin and glycerol on luminal organs was explored with ultrahigh-resolution spectral domain OCT at 800 nm. Ex vivo studies were performed on pig esophagus and bronchus, and guinea pig esophagus with different volume ratios of the mixture. We found that the mixture of 40% liquid paraffin had the best optical clearing effect on esophageal tissues with a short effective time of ˜10 min, which means the clearing effect occurs about 10 min after the application of the clearing agent. In contrast, no obvious optical clearing effect was identified on bronchus tissues.

  17. Achieving a predictable 24-hour return to normal activities after breast augmentation: part II. Patient preparation, refined surgical techniques, and instrumentation.

    PubMed

    Tebbetts, John B

    2006-12-01

    The goal of this study was to develop practices that would allow patients undergoing subpectoral augmentation to predictably return to full normal activities within 24 hours after the operation, free of postoperative adjuncts. Part I of this study used motion and time study principles to reduce operative times, medication dosages, perioperative morbidity, and recovery times in augmentation mammaplasty. Part II of the study focuses on details of patient education, preoperative planning, instrumentation, and surgical technique modifications that were identified, modified, and implemented to achieve the results reported in part I. Two groups of 16 patients each (groups 1 and 2) were studied retrospectively for comparison to a third group of 627 patients (group 3) studied prospectively. Patients in group 1 had axillary partial retropectoral breast augmentations in 1982-1983, using dissociative anesthesia, blunt instrument implant pocket dissection, and Dow Corning, double-lumen implants containing 20 mg of methylprednisolone and 20 cc of saline in the outer lumen of the implants. Patients in group 2 (1990) had inframammary, retromammary augmentations by using a combination of blunt and electrocautery dissection, Surgitek Replicon polyurethane-covered, silicone gel-filled implants, and general endotracheal anesthesia. Patients in group 3 (1998 to 2001, n = 627) had inframammary partial retropectoral, inframammary retromammary, and axillary partial retropectoral augmentations under general endotracheal anesthesia. Refined practices and surgical techniques from studies of groups 1 and 2 were applied in group 3. Videotapes from operative procedures of groups 1 and 2 were analyzed with macromotion and micromotion study principles, and tables of events were formulated for each move during the operation for all personnel in the operating room. Extensive details of surgical technique were examined and reexamined in 13 different stages by using principles of motion and time studies described in part I of this study to maximize efficiency without any change in quality. Unnecessary or unproductive motions and techniques were progressively eliminated, and essential, productive techniques were streamlined to eliminate wasted time and motion. Instrumentation and surgical techniques were evaluated in detail and modified to minimize bleeding and tissue trauma. Detailed data were presented in part I of this study that document shorter operative times, recovery times, time to discharge home, and time to return to normal activities. This part focuses on the patient education, preoperative planning, instrumentation, and surgical technique changes that were implemented on the basis of the findings in part I of the study. More extensive patient information integrated with staged informed consent resulted in a more in formed and confident patient. Applying motion and time study principles to analysis and refinement of instrumentation and surgical techniques resulted in a substantial reduction in perioperative morbidity and a simpler, shorter 24-hour return to full normal activity for 96 percent of the patients undergoing breast augmentation in group 3 compared with groups 1 and 2. More than 96 percent of patients in group 3 were able to return to normal activities, lift their arms above their heads, lift normal-weight objects, and drive their car within 24 hours after their partial retropectoral breast augmentation. Patient education, preoperative planning, instrumentation, and surgical technique modifications based on motion and time study video analyses reduced surgical trauma and bleeding, reduced perioperative morbidity, and allowed 96 percent of 627 breast augmentation patients in group 3 a predictable return to full, normal activity in 24 hours or less. Specific surgical factors that contributed to these results included (1) prospective hemostasis techniques with a zero tolerance for even the smallest amount of bleeding, (2) strict "no-touch" techniques for periosteum and perichondrium, (3) eliminating all blunt dissection, (4) performing all dissection under direct vision, (5) modified and simplified instrumentation, and (6) optimal use of muscle relaxants during subpectoral dissection.

  18. Achieving a predictable 24-hour return to normal activities after breast augmentation: Part II. Patient preparation, refined surgical techniques, and instrumentation.

    PubMed

    Tebbetts, John B

    2002-01-01

    The goal of this study was to develop practices that would allow patients undergoing subpectoral augmentation to predictably return to full normal activities within 24 hours after the operation, free of postoperative adjuncts. Part I of this study used motion and time study principles to reduce operative times, medication dosages, perioperative morbidity, and recovery times in augmentation mammaplasty. Part II of the study focuses on details of patient education, preoperative planning, instrumentation, and surgical technique modifications that were identified, modified, and implemented to achieve the results reported in part I. Two groups of 16 patients each (groups 1 and 2) were studied retrospectively for comparison to a third group of 627 patients (group 3) studied prospectively. Patients in group 1 had axillary partial retropectoral breast augmentations in 1982-1983, using dissociative anesthesia, blunt instrument implant pocket dissection, and Dow Corning, double-lumen implants containing 20 mg of methylprednisolone and 20 cc of saline in the outer lumen of the implants. Patients in group 2 (1990) had inframammary, retromammary augmentations by using a combination of blunt and electrocautery dissection, Surgitek Replicon polyurethane-covered, silicone gel-filled implants, and general endotracheal anesthesia. Patients in group 3 (1998 to 2001, n = 627) had inframammary partial retropectoral, inframammary retromammary, and axillary partial retropectoral augmentations under general endotracheal anesthesia. Refined practices and surgical techniques from studies of groups 1 and 2 were applied in group 3. Videotapes from operative procedures of groups 1 and 2 were analyzed with macromotion and micromotion study principles, and tables of events were formulated for each move during the operation for all personnel in the operating room. Extensive details of surgical technique were examined and reexamined in 13 different stages by using principles of motion and time studies described in part I of this study to maximize efficiency without any change in quality. Unnecessary or unproductive motions and techniques were progressively eliminated, and essential, productive techniques were streamlined to eliminate wasted time and motion. Instrumentation and surgical techniques were evaluated in detail and modified to minimize bleeding and tissue trauma. Detailed data were presented in part I of this study that document shorter operative times, recovery times, time to discharge home, and time to return to normal activities. This part focuses on the patient education, preoperative planning, instrumentation, and surgical technique changes that were implemented on the basis of the findings in part I of the study. More extensive patient information integrated with staged informed consent resulted in a more informed and confident patient. Applying motion and time study principles to analysis and refinement of instrumentation and surgical techniques resulted in a substantial reduction in perioperative morbidity and a simpler, shorter 24-hour return to full normal activity for 96 percent of the patients undergoing breast augmentation in group 3 compared with groups 1 and 2. More than 96 percent of patients in group 3 were able to return to normal activities, lift their arms above their heads, lift normal-weight objects, and drive their car within 24 hours after their partial retropectoral breast augmentation. Patient education, preoperative planning, instrumentation, and surgical technique modifications based on motion and time study video analyses reduced surgical trauma and bleeding, reduced perioperative morbidity, and allowed 96 percent of 627 breast augmentation patients in group 3 a predictable return to full, normal activity in 24 hours or less. Specific surgical factors that contributed to these results included (1) prospective hemostasis techniques with a zero tolerance for even the smallest amount of bleeding, (2) strict "no-touch" techniques for periosteum and perichondrium, (3) eliminating all blunt dissection, (4) performing all dissection under direct vision, (5) modified and simplified instrumentation, and (6) optimal use of muscle relaxants during subpectoral dissection.

  19. [Clinical analysis of LPFP, PFNA and BPH in treating femoral intertrochanteric fractures in elderly patients].

    PubMed

    Zhu, Li-Jun; Li, Xiao-Fei; Liu, Chao; Lyu, Cheng-Yu

    2017-07-25

    To evaluate the clinical results of locking proximal femur plate(LPFP), proximal femoral nail antirotation(PFNA) and bipolar hemiarthroplasty(BPH) in the treatment of femoral intertrochanteric fractures in elderly patients. Retrospective analysis of the 86 elderly patients with femoral intertrochanteric fractures during June 2011 and August 2016 were enrolled in this study. The patients were divided into 3 groups: 26 cases in LPFP group included 10 males and 16 females with an average age of (72.54±4.78) years old, 5 cases of type II of Evans, 12 cases of type III and 9 cases of type IV; 39 cases in PFNA group included 17 males and 22 females with an average age of 74.41±5.65, 11 cases of type II, 18 cases of type III and 10 cases of type IV; 21 cases in BPH group included 9 males and 12 females with an average age of 76.23±6.97, 1 case of type II, 10 cases of type III and 10 cases of type IV. The data of three groups were collected for statistical analysis on the following aspects: operation time, intraoperative blood loss, the length of hospital stay, postoperative complications and Harris score of the hip joint function. The wound healed well and no complication occurred. Eighty-four cases were follow-up, while 2 cases were lost, the follow-up rate was 97.6%. The patients were followed up for 22 to 41 months with an average of 26.3 months. For comparison of operation time and time of the hospital stay, BPH group was shorter than the LPFP and PFNA group( F =19.782, 21.981, P <0.05). For comparison of the intraoperative blood loss, the BPH group was less blood loss than the LPFP and PFNA group( F =12.976, P <0.05), while there was no significant means between the LPFP and PFNA group( t =10.879, P >0.05). For comparison of the postoperative complications, LPFP group was higher than BHP and PFNA group( F =30.976, P <0.05), while there was no significant means between LPFP and PFNA group( t =9.902, P >0.05). For comparison of the Harris score of the hip joint at 1 year after operation, BPH and PFNA group were both higher than LPFP group( F =19.692, P <0.05), while there was no significant means between BPH and PFNA group ( t =4.971, P >0.05). For elder patient with femoral intertrochanteric fracture, BPH could be the best optional for the shorter operation time and less complications. And the PFNA also could be optional choice for the patients while the LPFP was forbidden for the elder patients.

  20. Outcomes of radiofrequency ablation (RFA) and CO2 laser for early glottic cancer.

    PubMed

    Shuang, Yu; Li, Chao; Zhou, Xuan; Huang, Yongwang; Zhang, Lun

    2016-01-01

    In the present study, the voice and functional outcomes of radiofrequency ablation (RFA) and CO2 laser for early glottic cancer were evaluated. One hundred sixty eight patients with early glottic cancer from October 2007 to June 2015 were included. Ninety-seven patients underwent RFA and seventy-one patients underwent CO2 laser. The operation time and score of visual analog scale (VAS) for pain on the second day after surgery were recorded. The electronic laryngoscopy was performed at one week, one month and three months of postoperation. The operation time in RFA was shorter than that in CO2 laser (8.52±1.43min vs. 11.76±1.67min, P<0.05). There was no statistical difference in VAS scores between two operation methods (2.86±0.52 vs. 2.89±0.68, P>0.05). One month after operation, the mucosal recovery in RFA group was better than that in CO2 laser group (P<0.05). The alterations of acoustic parameters Jitter, Shimmer and HNR at three time points after operation showed statistical significances in both RFA and CO2 laser groups (P<0.05). The significant differences in acoustic parameters between two groups were also observed (P<0.05). There were no differences in three-year survival rate, local recurrence rate, recurrence rate with anterior commissure involvement and postoperative adhesion rate with anterior commissure between the patients with RFA and CO2 laser (P>0.05). No patient underwent tracheotomy and had symptoms of bucking, dyspnea, severe pain, hemoptysis and other serious complications. Both RFA and CO2 laser are safe and effective for the treatment of early glottic cancer. RFA has the advantage of quick voice recovery, low mucosa injury and short operation time, which is worthy for wide clinical application. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Shortcuts to adiabatic passage for fast generation of Greenberger-Horne-Zeilinger states by transitionless quantum driving.

    PubMed

    Chen, Ye-Hong; Xia, Yan; Song, Jie; Chen, Qing-Qin

    2015-10-28

    Berry's approach on "transitionless quantum driving" shows how to set a Hamiltonian which drives the dynamics of a system along instantaneous eigenstates of a reference Hamiltonian to reproduce the same final result of an adiabatic process in a shorter time. In this paper, motivated by transitionless quantum driving, we construct shortcuts to adiabatic passage in a three-atom system to create the Greenberger-Horne-Zeilinger states with the help of quantum Zeno dynamics and of non-resonant lasers. The influence of various decoherence processes is discussed by numerical simulation and the result proves that the scheme is fast and robust against decoherence and operational imperfection.

  2. FeF(3) catalyzed cascade C-C and C-N bond formation: synthesis of differentially substituted triheterocyclic benzothiazole functionalities under solvent-free condition.

    PubMed

    Atar, Amol B; Jeong, Yeon Tae

    2014-05-01

    A series of diverse polyfunctionalized triheterocyclic benzothiazoles were easily prepared in excellent yields via the Biginelli reaction of 2-aminobenzothiazole with substituted benzaldehydes and α-methylene ketones using FeF(3) as an expeditious catalyst under solvent-free conditions. The protocol provides a practical and straightforward approach toward highly functionalized triheterocyclic benzothiazole derivatives in excellent yields. The reaction was conveniently promoted by FeF(3) and the catalyst could be recovered easily after the reaction and reused without any loss of its catalytic activity. The advantageous features of this methodology are high atom economy, operational simplicity, shorter reaction time, convergence, and facile automation.

  3. Further refinements of the polyp snare for interuterine surgery--a new modality for treatment of myomas and polyps.

    PubMed

    McLucas, B

    1995-01-01

    Hysteroscopic treatment of 30 patients suffering from menorrhagia or post-partum complications was accomplished using an electrosurgical polyp snare. Using this method, 18 polyps and 12 myomas were successfully removed in less than twenty minutes without complications. Local anaesthesia was used in 12 patients. Three patients have presented with recurrence of menorrhagia, with a minimum of six months follow-up. Benefits of this technique compared to uterine resectoscopy include shorter operative time, decreased risk of fluid overload, and less risk of uterine perforation. The snare is difficult to use and a learning curve exists. Higher currents than that used for resection are required.

  4. Does intraoperative navigation improve the accuracy of mandibular angle osteotomy: Comparison between augmented reality navigation, individualised templates and free-hand techniques.

    PubMed

    Zhu, Ming; Liu, Fei; Zhou, Chaozheng; Lin, Li; Zhang, Yan; Chai, Gang; Xie, Le; Qi, Fazhi; Li, Qingfeng

    2018-04-11

    Augmented reality (AR)-based navigation surgery has evolved to be an advanced assisted technology. The aim of this study is to manifest the accuracy of AR navigation for the intraoperative mandibular angle osteotomy by comparing the navigation with other interventional techniques. A retrospective study was conducted with 93 post-surgical patients with mandibular angle hypertrophy admitted at our plastic and reconstructive surgery department between September 2011 and June 2016. Thirty-one patients received osteotomy conducted using a navigation system based on augmented reality (AR group), 28 patients received osteotomy conducted using individualised templates (IT group) and the remaining 34 patients received osteotomy performed by free hand (free-hand group). The post-operative computed tomography (CT) images were reviewed and analysed by comparing with pre-surgical planning generated by three-dimensional (3D) software. The preparation time, cutting time, whole operating time and discrepancy in osteotomy lines were measured. The preparation time was much shorter for the free-hand group than that for the AR group and the IT group (P < 0.01). However, no significant difference in the whole operating time was observed among the three groups (P > 0.05). In addition, the discrepancy in osteotomy lines was lower for the AR group and in the IT group than for the free-hand group (P < 0.01). The navigation system based on AR has a higher accuracy, more reliability and better user friendliness for some particular clinical procedures than for other techniques, which has a promising clinical prospect. Copyright © 2018. Published by Elsevier Ltd.

  5. Chewing Xylitol Gum could Accelerate Bowel motility Recovery after Elective Open Proctectomy for Rectal Cancer.

    PubMed

    Yang, Ping; Long, Wu Jun; Wei, Li

    2018-01-01

    A number of studies with conflicting results have evaluated the effect of chewing gum on post-operative gastrointestinal recovery in patients after major colorectal surgery. The objective of the study was to study the efficacy of chewing gum in patients with rectal cancer after elective open proctectomy only. A randomized controlled clinical trial was performed. We recruited patients who would undergo elective open proctectomy for rectal cancer in Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital. Patients in the intervention arm received chewing gum 3 times a day postoperatively. All patients in the trial were placed on the same perioperative management and standardized post-operative care plans. The primary outcome was time to the first peristalsis sounds, time to first flatus and the first defecation. A total of 89 patients were recruited. The time to the first flatus was 42.33 ± 3.46 h in the gum group and 49.20 ± 1.42 h in the control group (p < 0.05). The time to the first defecation was significantly shorter in the gum-chewing group than in the control group (66.07 ± 2.36 vs. 78.37 ± 1.62 h; p < 0.05). Post-operative ileus (POI) was confirmed in 2 patients in the gum-chewing group and in 7 in the control group (7.0% vs. 23.9%; p = 0.028). The present study suggests that chewing gum is a method to reduce the time to first flatus, time to first defecation and POI in patients undergoing elective open proctectomy for rectal cancer. Copyright: © 2017 SecretarÍa de Salud.

  6. The comparative evaluation of safety and efficacy of unilateral paravertebral block with conventional spinal anaesthesia for inguinal hernia repair

    PubMed Central

    Sinha, Sunil Kumar; Brahmchari, Yudhyavir; Kaur, Manpreet; Jain, Aruna

    2016-01-01

    Background and Aims: Unilateral paravertebral block (PVB) as a sole anaesthetic technique is underutilised even in experienced hands. Hence, this study was undertaken regarding the efficacy and safety of PVB and compared with subarachnoid block (SAB) for inguinal hernia repair procedures. Methods: Sixty-three consenting adult male patients scheduled for unilateral inguinal hernia repair were randomly assigned to receive either PVB or SAB (Group P: PVBs at T10–L2 levels, 5 mL of 0.5% bupivacaine at each segment; Group S: SAB at L3–L4 level with 12.5 mg 0.5% of hyperbaric bupivacaine). Primary objective was to compare duration of post-operative analgesia and time to reach discharge criteria (modified Aldrete scores and modified post-anaesthetic discharge scoring [PADS] scores). Secondary objectives were to compare the block characteristics (time required for performing the block, time to surgical anaesthesia, time to ambulation, time to the first analgesic, total rescue analgesic consumption) and adverse effects. Independent Student's t-test was used for continuous data and Pearson Chi-square test for categorical data. P <0.05 was considered as statistically significant. Results: The duration of post-operative analgesia (min) was 384.57 ± 38.67 in Group P and 194.27 ± 20.30 in Group S (P < 0.05). Modified PADS scores were significantly higher at 4 h and 6 h (P < 0.0001) in Group P. Time to reach the discharge criteria was early in Group P than Group S. Conclusion: PVB provides excellent post-operative analgesic conditions with lesser adverse effects and shorter time to reach the discharge criteria compared to SAB. PMID:27512167

  7. Implementation of real-time nonuniformity correction with multiple NUC tables using FPGA in an uncooled imaging system

    NASA Astrophysics Data System (ADS)

    Oh, Gyong Jin; Kim, Lyang-June; Sheen, Sue-Ho; Koo, Gyou-Phyo; Jin, Sang-Hun; Yeo, Bo-Yeon; Lee, Jong-Ho

    2009-05-01

    This paper presents a real time implementation of Non Uniformity Correction (NUC). Two point correction and one point correction with shutter were carried out in an uncooled imaging system which will be applied to a missile application. To design a small, light weight and high speed imaging system for a missile system, SoPC (System On a Programmable Chip) which comprises of FPGA and soft core (Micro-blaze) was used. Real time NUC and generation of control signals are implemented using FPGA. Also, three different NUC tables were made to make the operating time shorter and to reduce the power consumption in a large range of environment temperature. The imaging system consists of optics and four electronics boards which are detector interface board, Analog to Digital converter board, Detector signal generation board and Power supply board. To evaluate the imaging system, NETD was measured. The NETD was less than 160mK in three different environment temperatures.

  8. Satellite orbit and data sampling requirements

    NASA Technical Reports Server (NTRS)

    Rossow, William

    1993-01-01

    Climate forcings and feedbacks vary over a wide range of time and space scales. The operation of non-linear feedbacks can couple variations at widely separated time and space scales and cause climatological phenomena to be intermittent. Consequently, monitoring of global, decadal changes in climate requires global observations that cover the whole range of space-time scales and are continuous over several decades. The sampling of smaller space-time scales must have sufficient statistical accuracy to measure the small changes in the forcings and feedbacks anticipated in the next few decades, while continuity of measurements is crucial for unambiguous interpretation of climate change. Shorter records of monthly and regional (500-1000 km) measurements with similar accuracies can also provide valuable information about climate processes, when 'natural experiments' such as large volcanic eruptions or El Ninos occur. In this section existing satellite datasets and climate model simulations are used to test the satellite orbits and sampling required to achieve accurate measurements of changes in forcings and feedbacks at monthly frequency and 1000 km (regional) scale.

  9. Comparison of flexible ureterorenoscopy and mini-percutaneous nephrolithotomy in treatment of lower calyceal stones smaller than 2 cm.

    PubMed

    Akbulut, Fatih; Kucuktopcu, Onur; Kandemir, Emre; Sonmezay, Erkan; Simsek, Abdulmuttalip; Ozgor, Faruk; Binbay, Murat; Muslumanoglu, Ahmet Yaser; Gurbuz, Gokhan

    2016-01-01

    To compare the outcomes of flexible ureterorenoscopy (F-URS) and mini-percutaneous nephrolithotomy (mini-PNL) in the treatment of lower calyceal stones smaller than 2 cm. Patients who underwent F-URS and mini-PNL for the treatment of lower calyceal stones smaller than 2 cm between March 2009 and December 2014 were retrospectively evaluated. Ninety-four patients were divided into two groups by treatment modality: F-URS (Group 1: 63 patients) and mini-PNL (Group 2: 31 patients). All patients were preoperatively diagnosed with intravenous pyelography or computed tomography. Success rates for F-URS and mini-PNL at postoperative first month were 85.7% and 90.3%, respectively. Operation time, fluoroscopy time, and hospitalization time for F-URS and mini-PNL patients were 44.40 min, 2.9 min, 22.4 h, and 91.9 min, 6.4 min, and 63.8 h, respectively. All three parameters were significantly shorter among the F-URS group (p < 0.001). Postoperative hemoglobin drop was significantly lower in F-URS group compared to mini-PNL group (0.39 mg/dL vs. 1.15 mg/dL, p = 0.001). A comparison of complications according to the Clavien classification demonstrated significant differences between the groups (p = 0.001). More patients in the F-URS groups require antibiotics due to urinary tract infection, and more patients in the mini-PNL group required ureteral double J catheter insertion under general anesthesia. Although both F-URS and mini-PNL have similar success rates for the treatment of lower calyceal stones, F-URS appears to be more favorable due to shorter fluoroscopy and hospitalization times; and lower hemoglobin drops. Multicenter and studies using higher patient volumes are needed to confirm these findings.

  10. Maternal and fetal effect of misgav ladach cesarean section in nigerian women: a randomized control study.

    PubMed

    Ezechi, Oc; Ezeobi, Pm; Gab-Okafor, Cv; Edet, A; Nwokoro, Ca; Akinlade, A

    2013-10-01

    The poor utilisation of the Misgav-Ladach (ML) caesarean section method in our environment despite its proven advantage has been attributed to several factors including its non-evaluation. A well designed and conducted trial is needed to provide evidence to convince clinician of its advantage over Pfannenstiel based methods. To evaluate the outcome of ML based caesarean section among Nigerian women. Randomised controlled open label study of 323 women undergoing primary caesarean section in Lagos Nigeria. The women were randomised to either ML method or Pfannenstiel based (PB) caesarean section technique using computer generated random numbers. The mean duration of surgery (P < 0.001), time to first bowel motion (P = 0.01) and ambulation (P < 0.001) were significantly shorter in the ML group compared to PB group. Postoperative anaemia (P < 0.01), analgesic needs (P = 0.02), extra suture use, estimated blood loss (P < 0.01) and post-operative complications (P = 0.001) were significantly lower in the ML group compared to PB group. Though the mean hospital stay was shorter (5.8 days) in the ML group as against 6.0 days, the difference was not significant statistically (P = 0.17). Of the fetal outcome measures compared, it was only in the fetal extraction time that there was significant difference between the two groups (P = 0.001). The mean fetal extraction time was 162 sec in ML group compared to 273 sec in the PB group. This study confirmed the already established benefit of ML techniques in Nigerian women, as it relates to the postoperative outcomes, duration of surgery, and fetal extraction time. The technique is recommended to clinicians as its superior maternal and fetal outcome and cost saving advantage makes it appropriate for use in poor resource setting.

  11. Urethroplasty for treatment of long anterior urethral stricture: buccal mucosa graft versus penile skin graft-does the stricture length matter?

    PubMed

    Hussein, Mohamed M; Almogazy, Hazem; Mamdouh, Ahmed; Farag, Fawzy; Rashed, Elnesr; Gamal, Wael; Rashed, Ahmed; Zaki, Mohamed; Salem, Esam; Ryad, Ahmed

    2016-11-01

    To investigate the surgical outcomes of dorsal onlay urethroplasty (DOU) using buccal mucosa graft (BMG) or penile skin graft (PSG) and to assess the effect of stricture length in men with anterior urethral strictures. A prospective cohort included men with anterior urethral strictures between 2008 and 2015. Patients underwent DOU using PSG or BMG. Patients had urethrography and uroflowmetry at 0, 3, 6, 12 months, and urethroscopy when needed. Student's t test, Mann-Whitney U tests, and Pearson's Chi-square test were used for analysis. Sixty-nine patients (43 ± 14 year) were included, 31 received BMG, and 38 received PSG. Mean stricture length was 8 ± 3 cm, mean operative time was 145 ± 31 min, and mean follow-up was 56 ± 10 mo. Success rate was 87 % (90 % BMG vs. 84 % PSG, p = 0.4). Mean operative time was significantly shorter in PSG group (136 ± 29 min vs. 256 ± 58 min, p = 0.0005). Complications of grade I developed in 36 % (wound infection = 10 %, postvoiding dribbling = 18.8 %). Thirty of 69 patients (43 %) had strictures ≥8 cm, and 39 (57 %) had strictures <8 cm-success rate was equal for both subgroups (87 %). Mean blood loss, mean operative time, and incidence of postvoid dribbling were significantly lower in strictures <8 cm. BMG and PSG have comparable success rates in treatment of long anterior urethral strictures. Operative time is significantly longer in BMG. Long-segment strictures are associated with longer operative time, more blood loss, and more occurrence of postvoid dribbling. However, the length of the stricture has no influence on the success rate and functional outcomes of DOU.

  12. Simultaneous image reproduction on CRT screen: Moves ultrasonic sectional view and electrocardiogram curves

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A method for simultaneous reproduction of images, requiring different amounts of time to reproduce, on a cathode ray tube (CRT) screen is disclosed. Ultrasonic sectional views and electrocardiogram curves are simultaneously reproduced on the CRT screen by producing the images on different areas of a screen with two phosphors having different persistence times and luminous colors, within the times required for the appearance of the images. In front of the area on which is produced the image requiring the shorter time is a color filter which is permeable to the color of the phosphor with the shorter persistence time by which absorbs the color of the other phosphor.

  13. Direct cost comparison of minimally invasive punch technique versus traditional approaches for percutaneous bone anchored hearing devices.

    PubMed

    Sardiwalla, Yaeesh; Jufas, Nicholas; Morris, David P

    2017-06-12

    Minimally Invasive Ponto Surgery (MIPS) was recently described as a new technique to facilitate the placement of percutaneous bone anchored hearing devices. The procedure has resulted in a simplification of the surgical steps and a dramatic reduction in surgical time while maintaining excellent patient outcomes. Given these developments, our group sought to move the procedure from the main operating suite where they have traditionally been performed. This study aims to test the null hypothesis that MIPS and open approaches have the same direct costs for the implantation of percutaneous bone anchored hearing devices in a Canadian public hospital setting. A retrospective direct cost comparison of MIPS and open approaches for the implantation of bone conduction implants was conducted. Indirect and future costs were not included in the fiscal analysis. A simple cost comparison of the two approaches was made considering time, staff and equipment needs. All 12 operations were performed on adult patients from 2013 to 2016 by the same surgeon at a single hospital site. MIPS has a total mean reduction in cost of CAD$456.83 per operation from the hospital perspective when compared to open approaches. The average duration of the MIPS operation was 7 min, which is on average 61 min shorter compared with open approaches. The MIPS technique was more cost effective than traditional open approaches. This primarily reflects a direct consequence of a reduction in surgical time, with further contributions from reduced staffing and equipment costs. This simple, quick intervention proved to be feasible when performed outside the main operating room. A blister pack of required equipment could prove convenient and further reduce costs.

  14. Defining the cost of care for lobectomy and segmentectomy: a comparison of open, video-assisted thoracoscopic, and robotic approaches.

    PubMed

    Deen, Shaun A; Wilson, Jennifer L; Wilshire, Candice L; Vallières, Eric; Farivar, Alexander S; Aye, Ralph W; Ely, Robson E; Louie, Brian E

    2014-03-01

    Knowledge about the cost of open, video-assisted thoracoscopic (VATS), or robotic lung resection and drivers of cost is crucial as the cost of care comes under scrutiny. This study aims to define the cost of anatomic lung resection and evaluate potential cost-saving measures. A retrospective review of patients who had anatomic resection for early stage lung cancer, carcinoid, or metastatic foci between 2008 and 2012 was performed. Direct hospital cost data were collected from 10 categories. Capital depreciation was separated for the robotic and VATS cases. Key costs were varied in a sensitivity analysis. In all, 184 consecutive patients were included: 69 open, 57 robotic, and 58 VATS. Comorbidities and complication rates were similar. Operative time was statistically different among the three modalities, but length of stay was not. There was no statistically significant difference in overall cost between VATS and open cases (Δ = $1,207) or open and robotic cases (Δ = $1,975). Robotic cases cost $3,182 more than VATS (p < 0.001) owing to the cost of robotic-specific supplies and depreciation. The main opportunities to reduce cost in open cases were the intensive care unit, respiratory therapy, and laboratories. Lowering operating time and supply costs were targets for VATS and robotic cases. VATS is the least expensive surgical approach. Robotic cases must be shorter in operative time or reduce supply costs, or both, to be competitive. Lessening operating time, eradicating unnecessary laboratory work, and minimizing intensive care unit stays will help decrease direct hospital costs. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Right mini-parasternotomy may be a good minimally invasive alternative to full sternotomy for cardiac valve operations-a propensity-adjusted analysis.

    PubMed

    Chiu, K M; Chen, R J; Lin, T Y; Chen, J S; Huang, J H; Huang, C Y; Chu, S H

    2014-03-26

    Limited realworld data existed for miniparasternotomy approach with good sample size in Asian cohorts and most previous studies were eclipsed by case heterogeneity. The goal of this study was to compare safety and quality outcomes of cardiac noncoronary valve operations by miniparasternotomy and full sternotomy approaches on riskadjusted basis. From our hospital database, we retrieved the cases of non-coronary valve operations from 1 January 2005 to 31 December 2012, including re-do, emergent, and combined procedures. Estimated EuroScore-II and propensity score for choosing mini-parasternotomy were adjusted for in the regression models on hospital mortality, complications (pneumonia, stroke, sepsis, etc.), and quality parameters (length of stay, ICU time, ventilator time, etc.). Non-complicated cases, defined as survival to discharge, ventilator use not over one week, and intensive care unit stay not over two weeks, were used for quality parameters. There were 283 miniparasternotomy and 177 full sternotomy cases. EuroScore-II differed significantly (medians 2.1 vs. 4.7, p<0.001). Propensity scores for choosing miniparasternotomy were higher with lower EuroScore-II (OR=0.91 per 1%, p<0.001), aortic regurgitation (OR=2.3, p=0.005), and aortic non-mitral valve disease (OR=3.9, p<0.001). Adjusted for propensity score and EuroScore-II, mini-parasternotomy group had less pneumonia (OR=0.32, p=0.043), less sepsis (OR=0.31, p=0.045), and shorter non-complicated length of stay (coefficient=7.2 (day), p<0.001) than full sternotomy group, whereas Kaplan-Meier survival, non-complicated ICU time, non-complicated ventilator time, and 30-day mortality did not differ significantly. The propensity-adjusted analysis demonstrated encouraging safety and quality outcomes for mini-parasternotomy valve operation in carefully selected patients.

  16. [A Comparative Study of Acute and Chronic Pain between Single Port and Triple Port Video-assisted Thoracic Surgery for Lung Cancer].

    PubMed

    Li, Caiwei; Xu, Meiqing; Xu, Guangwen; Xiong, Ran; Wu, Hanran; Xie, Mingran

    2018-04-20

    Through the comparative analysis of the acute and chronic pain postoperative between the single port and triple port video-assisted thoracic surgery to seek the better method which can reduce the incidence of acute and chronic pain in patients with lung cancer. Data of 232 patients who underwent single port -VATS (n=131) or triple port VATS (n=101) for non-small cell lung cancer (NSCLC) on January 1, 2016 to June 30, 2017 in our hospital were analyzed. The clinical and operative data were assessed, numeric rating scale (NRS) was used to evaluate the mean pain score on the 1th, 2th, 3th, 7th, 14th days, 3th months and 6th months postoperative. Both groups were similar in clinical characteristics, there were no perioperative death in two groups. In the 1th, 2th, 7th, 14th days and 3th, 6th months postoperative, the NRS score of the single port group was superior, and the difference was significant compared with the triple port (P<0.05). There was no statistically significant difference between the two groups in operative time, blood loss, postoperative hospitalization time, duration of chest tube, the NRS scores in the 3 d (P>0.05). Univariate and multivariate analysis of the occurrence on the chronic pain showed that the operation time, surgical procedure and the 14th NRS score were risk factors for chronic pain (P<0.05). The single port thoracoscopic surgery has an advantage in the incidence of acute and chronic pain in patients with non-small cell lung cancer. Shorter operative time can reduce the occurrence of chronic pain. The 14th day NRS score is a risk factor for chronic pain postoperative.

  17. Improving Minimally Invasive Adrenalectomy: Selection of Optimal Approach and Comparison of Outcomes.

    PubMed

    Lairmore, Terry C; Folek, Jessica; Govednik, Cara M; Snyder, Samuel K

    2016-07-01

    Minimally invasive adrenalectomy is commonly performed by either a transperitoneal laparoscopic (TLA) or posterior retroperitoneoscopic (PRA) approach. Our group described the technique for robot-assisted PRA (RAPRA) in 2010. Few studies are available that directly compare outcomes between the available operative approaches. We reviewed our results for minimally invasive adrenalectomy using the three different approaches over a 10-year period. Between January 2005 and April 2015, 160 minimally invasive adrenalectomies were performed. Clinicopathologic data were prospectively collected and retrospectively analyzed. The primary endpoints evaluated were operative time, blood loss, length of stay (LOS), and morbidity. The study included 67 TLA, 76 PRA, and 17 RAPRA procedures. Tumor size for PRA/RAPRA was smaller than for patients undergoing TLA (2.38 vs 3.6 cm, p ≤ 0.0001). Procedure time was shorter for PRA versus TLA (133.3 vs 152.8 min, p = 0.0381), as was LOS (1.85 vs 2.82 days, p = 0.0145). Procedure time was longer in RAPRA versus TLA/PRA (177 vs 153/133 min, p = 0.008), but LOS was significantly decreased (1.53 vs 2.82/1.85 days, p = 0.004). Minimally invasive adrenalectomy is associated with expected excellent outcomes regardless of approach. In our series, the posterior approach is associated with decreased operative time and LOS. Robotic technology provides potential advantages for the surgeon at the expense of more complex setup requirements and costs. Further study is required to demonstrate clear benefit of one surgical approach. Utilization of the entire spectrum of available operative techniques can allow for selection of the optimal approach based on individual patient factors.

  18. Right anterior mini-thoracotomy vs. conventional sternotomy for aortic valve replacement: a propensity-matched comparison

    PubMed Central

    Del Giglio, Mauro; Mikus, Elisa; Micari, Antonio; Calvi, Simone; Tripodi, Alberto; Campo, Gianluca; Maietti, Elisa; Castriota, Fausto; Cremonesi, Alberto

    2018-01-01

    Background Right anterior mini-thoracotomy (MIAVR) is a promising technique for aortic valve replacement. We aimed at comparing its outcomes with those obtained in a propensity-matched group of patients undergoing sternotomy at our two high-volume centers. Methods Main clinical and operative data of patients undergoing aortic valve replacement between January 2010 and May 2016 were retrospectively collected. A total of 678 patients were treated with a standard full sternotomy approach, while MIAVR was performed in 502. Propensity score matching identified 363 patients per each group. Results In-hospital mortality was not significantly different between the propensity-matched groups (1.7% in MIAVR patients vs. 2.2% in conventional sternotomy patients; P=0.79). No significant difference in the incidence of major post-operative complications was observed. Post-operative ventilation times (median 7, range 5–12 hours in MIAVR patients vs. median 7, range 5–12 in conventional sternotomy patients; P=0.72) were not significantly different between the two groups. Cardiopulmonary bypass time (61.0±21.0 vs. 65.9±24.7 min in conventional sternotomy group; P<0.01) and aortic cross-clamping time (48.3±16.7 vs. 53.2±19.6 min in full sternotomy group; P<0.01) were shorter in MIAVR group. EuroSCORE (OR 1.52, 95% CI, 1.12–2.06; P<0.01) was found to be the only independent predictor of intra-hospital mortality in the whole propensity-matched population. Conclusions Our experience shows that mini-access isolated aortic valve surgery is a reproducible, safe and effective procedure with similar outcomes and no longer operative times compared to conventional sternotomy. PMID:29707310

  19. Ultrafast charge separation dynamics in opaque, operational dye-sensitized solar cells revealed by femtosecond diffuse reflectance spectroscopy

    PubMed Central

    Ghadiri, Elham; Zakeeruddin, Shaik M.; Hagfeldt, Anders; Grätzel, Michael; Moser, Jacques-E.

    2016-01-01

    Efficient dye-sensitized solar cells are based on highly diffusive mesoscopic layers that render these devices opaque and unsuitable for ultrafast transient absorption spectroscopy measurements in transmission mode. We developed a novel sub-200 femtosecond time-resolved diffuse reflectance spectroscopy scheme combined with potentiostatic control to study various solar cells in fully operational condition. We studied performance optimized devices based on liquid redox electrolytes and opaque TiO2 films, as well as other morphologies, such as TiO2 fibers and nanotubes. Charge injection from the Z907 dye in all TiO2 morphologies was observed to take place in the sub-200 fs time scale. The kinetics of electron-hole back recombination has features in the picosecond to nanosecond time scale. This observation is significantly different from what was reported in the literature where the electron-hole back recombination for transparent films of small particles is generally accepted to occur on a longer time scale of microseconds. The kinetics of the ultrafast electron injection remained unchanged for voltages between +500 mV and –690 mV, where the injection yield eventually drops steeply. The primary charge separation in Y123 organic dye based devices was clearly slower occurring in two picoseconds and no kinetic component on the shorter femtosecond time scale was recorded. PMID:27095505

  20. Audit system on Quality of breast cancer diagnosis and Treatment (QT): results of quality indicators on screen-detected lesions in Italy, 2011-2012.

    PubMed

    Ponti, Antonio; Mano, Maria Piera; Tomatis, Mariano; Baiocchi, Diego; Barca, Alessandra; Berti, Rosa; Casella, Denise; D'Ambrosio, Enrico; Delos, Erika; Donati, Giovanni; Falcini, Fabio; Frammartino, Brunella; Frigerio, Alfonso; Giudici, Fabiola; Mantellini, Paola; Naldoni, Carlo; Olla Atzeni, Carlo; Orzalesi, Lorenzo; Pagano, Giovanni; Pietribiasi, Francesca; Pitarella, Sabina; Ravaioli, Alessandra; Silvestri, Anna; Taffurelli, Mario; Tidone, Enrica; Zanconati, Fabrizio; Segnan, Nereo

    2015-01-01

    This annual survey, conducted by the Italian group for mammography screening (GISMa), collects individual data on diagnosis and treatment of about 50% of screen-detected, operated lesions in Italy. The 2011-2012 results show good overall quality and an improving trend over time. A number of critical issues have been identified, including waiting times (which have had a worsening trend over the years) and compliance with the recommendation of not performing frozen section examination on small lesions. Pre-operative diagnosis improved constantly over time, but there is still a large variation between Regions and programmes. For almost 90% of screen-detected invasive cancers a sentinel lymph node (SLN) biopsy was performed on the axilla, avoiding a large number of potentially harmful dissections. On the other hand, potential overuse of SLN dissection for ductal carcinoma in situ, although apparently starting to decline, deserves further investigation. The detailed results have been distributed, among other ways by means of a web-based data-warehouse, to regional and local screening programmes, in order to allow multidisciplinary discussion and identification of the appropriate solutions to any issues documented by the data. The problem of waiting times should be assigned priority. Specialist Breast Units with adequate case volume and enough resources would provide the best setting for making monitoring effective in producing quality improvements with shorter waiting times.

  1. Tether dynamics and control results for tethered satellite system's initial flight

    NASA Astrophysics Data System (ADS)

    Chapel, Jim D.; Flanders, Howard

    The recent Tethered Satellite System-1 (TSS-1) mission has provided a wealth of data concerning the dynamics of tethered systems in space and has demonstrated the effectiveness of operational techniques designed to control these dynamics. In this paper, we review control techniques developed for managing tether dynamics, and discuss the results of using these techniques for the Tethered Satellite System's maiden flight on STS-46. In particular, the flight results of controlling libration dynamics, string dynamics, and slack tether are presented. These results show that tether dynamics can be safely managed. The overall stability of the system was found to be surprisingly good even at relatively short tether lengths. In fact, the system operated in passive mode at a tether length of 256 meters for over 9 hours. Only monitoring of the system was required during this time. Although flight anomalies prevented the planned deployment to 20 km, the extended operations at shorter tether lengths have proven the viability of using tethers in space. These results should prove invaluable in preparing for future missions with tethered objects in space.

  2. Tether dynamics and control results for tethered satellite system's initial flight

    NASA Technical Reports Server (NTRS)

    Chapel, Jim D.; Flanders, Howard

    1993-01-01

    The recent Tethered Satellite System-1 (TSS-1) mission has provided a wealth of data concerning the dynamics of tethered systems in space and has demonstrated the effectiveness of operational techniques designed to control these dynamics. In this paper, we review control techniques developed for managing tether dynamics, and discuss the results of using these techniques for the Tethered Satellite System's maiden flight on STS-46. In particular, the flight results of controlling libration dynamics, string dynamics, and slack tether are presented. These results show that tether dynamics can be safely managed. The overall stability of the system was found to be surprisingly good even at relatively short tether lengths. In fact, the system operated in passive mode at a tether length of 256 meters for over 9 hours. Only monitoring of the system was required during this time. Although flight anomalies prevented the planned deployment to 20 km, the extended operations at shorter tether lengths have proven the viability of using tethers in space. These results should prove invaluable in preparing for future missions with tethered objects in space.

  3. A systematic review and cost analysis of robot-assisted hysterectomy in malignant and benign conditions.

    PubMed

    Tapper, Anna-Maija; Hannola, Mikko; Zeitlin, Rainer; Isojärvi, Jaana; Sintonen, Harri; Ikonen, Tuija S

    2014-06-01

    In order to assess the effectiveness and costs of robot-assisted hysterectomy compared with conventional techniques we reviewed the literature separately for benign and malignant conditions, and conducted a cost analysis for different techniques of hysterectomy from a hospital economic database. Unlimited systematic literature search of Medline, Cochrane and CRD databases produced only two randomized trials, both for benign conditions. For the outcome assessment, data from two HTA reports, one systematic review, and 16 original articles were extracted and analyzed. Furthermore, one cost modelling and 13 original cost studies were analyzed. In malignant conditions, less blood loss, fewer complications and a shorter hospital stay were considered as the main advantages of robot-assisted surgery, like any mini-invasive technique when compared to open surgery. There were no significant differences between the techniques regarding oncological outcomes. When compared to laparoscopic hysterectomy, the main benefit of robot-assistance was a shorter learning curve associated with fewer conversions but the length of robotic operation was often longer. In benign conditions, no clinically significant differences were reported and vaginal hysterectomy was considered the optimal choice when feasible. According to Finnish data, the costs of robot-assisted hysterectomies were 1.5-3 times higher than the costs of conventional techniques. In benign conditions the difference in cost was highest. Because of expensive disposable supplies, unit costs were high regardless of the annual number of robotic operations. Hence, in the current distribution of cost pattern, economical effectiveness cannot be markedly improved by increasing the volume of robotic surgery. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. Plate fixation versus intramedullary nailing of completely displaced midshaft fractures of the clavicle: a prospective randomised controlled trial.

    PubMed

    Fuglesang, H F S; Flugsrud, G B; Randsborg, P H; Oord, P; Benth, J Š; Utvåg, S E

    2017-08-01

    This is a prospective randomised controlled trial comparing the functional outcomes of plate fixation and elastic stable intramedullary nailing (ESIN) of completely displaced mid-shaft fractures of the clavicle in the active adult population. We prospectively recruited 123 patients and randomised them to either plate fixation or ESIN. Patients completed the Quick Disabilities of the Arm, Shoulder and Hand (DASH) score at one to six weeks post-operatively. They were followed up at six weeks, three and six months and one year with radiographs, and their clinical outcome was assessed using both the DASH and the Constant Score. Plate fixation provided a faster functional recovery during the first six months compared with ESIN, but there was no difference after one year. The duration of surgery was shorter for ESIN (mean 53.4 minutes, 22 to 120) than for plate fixation (mean 69.7 minutes, 35 to 106, p < 0.001). The recovery after ESIN was slower with increasing fracture comminution and with open reduction (p < 0.05). Both methods return the patients to their pre-injury functional levels, but plate fixation has a faster recovery period in comminuted fractures than ESIN. ESIN has a shorter operative time and lower infection and implant rates of failure when using 2.5 mm nails or wider, suggesting that this is the preferred method in mid-shaft fractures with no comminution, whereas plate fixation is the superior method in comminuted fractures. Cite this article: Bone Joint J 2017;99-B:1095-1101. ©2017 The British Editorial Society of Bone & Joint Surgery.

  5. Effects of media stray field on electromigration characteristics in current-perpendicular-to-plane giant magnetoresistance spin-valve read sensors

    NASA Astrophysics Data System (ADS)

    Gui Zeng, Ding; Lee, Kyoung-il; Chung, Kyung-Won; Bae, Seongtae

    2012-05-01

    Effects of magnetic stray field retrieved from both longitudinal and perpendicular magnetic recording media (denoted by "media stray field") on electromigration (EM) characteristics of current-perpendicular-to-plane (CPP) giant magnetoresistance spin-valve (GMR SV) read sensors have been numerically studied to explore the electrical and magnetic stability of the read sensor under real operation. The mean-time-to-failure (MTTF) of the CPP GMR SV read sensors was found to have a strong dependence on the physical parameters of the recording media and recorded information status, such as the pulse width of media stray field, the bit length, and the head moving velocity. According to the numerical calculation results, it was confirmed that in the longitudinal media, the shorter the stray field pulse width (i.e., the sharper the media transition) allows for the longer MTTF of the CPP GMR SV read sensors; while in the perpendicular media, the sharper the media transition gives rise to a shorter MTTF. Interestingly, it was also revealed that the MTTF could be improved by reducing the bit length as well as increasing the head velocity in both longitudinal and perpendicular media. Furthermore, the bit distribution patterns, especially the number of consecutive `0' bits strongly affected the MTTF of GMR SV read sensors. The strong dependences of MTTF on the media stray field during CPP GMR SV sensor operation are thought to be mainly attributed to the thermal cycling (temperature rise and fall) caused by the resistance change due to GMR effects.

  6. Anesthetic drugs and onset of malignant hyperthermia.

    PubMed

    Visoiu, Mihaela; Young, Michael C; Wieland, Keith; Brandom, Barbara W

    2014-02-01

    The time between the beginning of anesthetic administration and recognition of the first sign of malignant hyperthermia (MH) (MH onset time) could differ among anesthetic drugs. We examined the time of the first signs of suspected MH, anesthetic drugs administered, subject age, and year of event in Adverse Metabolic/Musculoskeletal Reaction to Anesthesia reports in the North American Malignant Hyperthermia Registry. Inclusion criteria were judgment by the reporting clinician that the event was possible or fulminant MH, documentation of the time when anesthetic administration began, and the time when the first MH sign was noted. Descriptive statistics, Kruskal-Wallis analysis, and nonparametric correlation were used to assess the difference in MH onset times under different conditions. Four hundred seventy-seven cases met inclusion criteria; 58.5% were possible MH and 41.5% fulminant MH. Inhaled anesthetic and succinylcholine were given in 53.9% of cases, inhaled anesthetic only in 41.7%, and succinylcholine without inhaled anesthetics in 2.9%. No causative anesthetic drugs were reported in 7 MH cases. In 394 patients exposed to only 1 of the 4 inhaled anesthetics, without regard for subject age, MH onset time was shorter in the presence of halothane than any of the other anesthetics and shorter after succinylcholine in all anesthetics. If succinylcholine was not given, MH onset was shorter during sevoflurane anesthesia than during desflurane or isoflurane. In 322 cases, 1 rather than multiple first signs of MH were reported with masseter spasm as the earliest MH sign. In 339 cases in which masseter spasm was not reported, there was no difference in MH onset time with or without succinylcholine. In 146 cases in which masseter spasm was not reported and succinylcholine was not given, MH onset was shorter during halothane anesthesia, than during exposure to desflurane, or isoflurane. MH onset time during sevoflurane was shorter than during desflurane or isoflurane. MH was reported later in the course of anesthesia after 1998, when halothane and succinylcholine were less often reported. MH occurred after succinylcholine administration in the absence of inhaled anesthetics. We could not separate an effect of age from that of other variables. The onset of MH has been observed later during desflurane and isoflurane anesthesia than during exposure to sevoflurane. Since 1998, MH signs have more often appeared later, in the second or third hour of anesthesia, than they did before 1998.

  7. Call-to-balloon time dashboard in patients with ST-segment elevation myocardial infarction results in significant improvement in the logistic chain.

    PubMed

    Hermans, Maaike P J; Velders, Matthijs A; Smeekes, Martin; Drexhage, Olivier S; Hautvast, Raymond W M; Ytsma, Timon; Schalij, Martin J; Umans, Victor A W M

    2017-08-04

    Timely reperfusion with primary percutaneous coronary intervention (pPCI) in ST-segment elevation myocardial infarction (STEMI) patients is associated with superior clinical outcomes. Aiming to reduce ischaemic time, an innovative system for home-to-hospital (H2H) time monitoring was implemented, which enabled real-time evaluation of ischaemic time intervals, regular feedback and improvements in the logistic chain. The objective of this study was to assess the results after implementation of the H2H dashboard for monitoring and evaluation of ischaemic time in STEMI patients. Ischaemic time in STEMI patients transported by emergency medical services (EMS) and treated with pPCI in the Noordwest Ziekenhuis, Alkmaar before (2008-2009; n=495) and after the implementation of the H2H dashboard (2011-2014; n=441) was compared. Median time intervals were significantly shorter in the H2H group (door-to-balloon time 32 [IQR 25-43] vs. 40 [IQR 28-55] minutes, p-value <0.001, FMC-to-balloon time 62 [IQR 52-75] vs. 80 [IQR 67-103] minutes, p-value <0.001, and treatment delay 142 [IQR 103-221] vs. 159 [IQR 123-253] minutes, p-value <0.001). The H2H time dashboard was independently associated with shorter time delays. Real-time monitoring and feedback on time delay with the H2H dashboard improves the logistic chain in STEMI patients, resulting in shorter ischaemic time intervals.

  8. Compartmentalized self-replication under fast PCR cycling conditions yields Taq DNA polymerase mutants with increased DNA-binding affinity and blood resistance.

    PubMed

    Arezi, Bahram; McKinney, Nancy; Hansen, Connie; Cayouette, Michelle; Fox, Jeffrey; Chen, Keith; Lapira, Jennifer; Hamilton, Sarah; Hogrefe, Holly

    2014-01-01

    Faster-cycling PCR formulations, protocols, and instruments have been developed to address the need for increased throughput and shorter turn-around times for PCR-based assays. Although run times can be cut by up to 50%, shorter cycle times have been correlated with lower detection sensitivity and increased variability. To address these concerns, we applied Compartmentalized Self Replication (CSR) to evolve faster-cycling mutants of Taq DNA polymerase. After five rounds of selection using progressively shorter PCR extension times, individual mutations identified in the fastest-cycling clones were randomly combined using ligation-based multi-site mutagenesis. The best-performing combinatorial mutants exhibit 35- to 90-fold higher affinity (lower Kd ) for primed template and a moderate (2-fold) increase in extension rate compared to wild-type Taq. Further characterization revealed that CSR-selected mutations provide increased resistance to inhibitors, and most notably, enable direct amplification from up to 65% whole blood. We discuss the contribution of individual mutations to fast-cycling and blood-resistant phenotypes.

  9. Description of the life stages of quill mite Mironovia lagopus sp. nov. (Acari: Syringophilidae) parasitizing the rock ptarmigan Lagopus muta (Phasianidae) from Iceland.

    PubMed

    Bochkov, Andre V; Skirnisson, Karl

    2011-03-01

    A new species of syringophilid mites, Mironovia lagopus sp. nov. (Acari: Syringophilidae) is described from feather quills of the rock ptarigman Lagopus muta (Montin) (Phasianidae) from Iceland. Females of this new species differ from the closely related Mironovia rouloul Skoracki and Sikora by setae d2, which are subequal or 1.1-1.2 times shorter than setae e2 (vs. d2 1.4-1.5 times longer than e2 in Mironovia rouloul) and by setae ag1, which are 1.3-1.5 times shorter than ag2 (vs. ag1 1.7-1.8 times shorter than ag2). The postembryonic stages of this new species are figured and described in details. In ontogeny of Mironovia spp., the observed pattern of setal appearance is not different from the pattern in other galliform-associated genera such as Syringophilus and Colinophilus, with exception for tarsal setae p'I, II which are absent in protonymphs. The key to all four species of the genus Mironovia is also provided.

  10. Automated fault-management in a simulated spaceflight micro-world

    NASA Technical Reports Server (NTRS)

    Lorenz, Bernd; Di Nocera, Francesco; Rottger, Stefan; Parasuraman, Raja

    2002-01-01

    BACKGROUND: As human spaceflight missions extend in duration and distance from Earth, a self-sufficient crew will bear far greater onboard responsibility and authority for mission success. This will increase the need for automated fault management (FM). Human factors issues in the use of such systems include maintenance of cognitive skill, situational awareness (SA), trust in automation, and workload. This study examine the human performance consequences of operator use of intelligent FM support in interaction with an autonomous, space-related, atmospheric control system. METHODS: An expert system representing a model-base reasoning agent supported operators at a low level of automation (LOA) by a computerized fault finding guide, at a medium LOA by an automated diagnosis and recovery advisory, and at a high LOA by automate diagnosis and recovery implementation, subject to operator approval or veto. Ten percent of the experimental trials involved complete failure of FM support. RESULTS: Benefits of automation were reflected in more accurate diagnoses, shorter fault identification time, and reduced subjective operator workload. Unexpectedly, fault identification times deteriorated more at the medium than at the high LOA during automation failure. Analyses of information sampling behavior showed that offloading operators from recovery implementation during reliable automation enabled operators at high LOA to engage in fault assessment activities CONCLUSIONS: The potential threat to SA imposed by high-level automation, in which decision advisories are automatically generated, need not inevitably be counteracted by choosing a lower LOA. Instead, freeing operator cognitive resources by automatic implementation of recover plans at a higher LOA can promote better fault comprehension, so long as the automation interface is designed to support efficient information sampling.

  11. Real-time processing for full-range Fourier-domain optical-coherence tomography with zero-filling interpolation using multiple graphic processing units.

    PubMed

    Watanabe, Yuuki; Maeno, Seiya; Aoshima, Kenji; Hasegawa, Haruyuki; Koseki, Hitoshi

    2010-09-01

    The real-time display of full-range, 2048?axial pixelx1024?lateral pixel, Fourier-domain optical-coherence tomography (FD-OCT) images is demonstrated. The required speed was achieved by using dual graphic processing units (GPUs) with many stream processors to realize highly parallel processing. We used a zero-filling technique, including a forward Fourier transform, a zero padding to increase the axial data-array size to 8192, an inverse-Fourier transform back to the spectral domain, a linear interpolation from wavelength to wavenumber, a lateral Hilbert transform to obtain the complex spectrum, a Fourier transform to obtain the axial profiles, and a log scaling. The data-transfer time of the frame grabber was 15.73?ms, and the processing time, which includes the data transfer between the GPU memory and the host computer, was 14.75?ms, for a total time shorter than the 36.70?ms frame-interval time using a line-scan CCD camera operated at 27.9?kHz. That is, our OCT system achieved a processed-image display rate of 27.23 frames/s.

  12. The practical use of simplicity in developing ground water models

    USGS Publications Warehouse

    Hill, M.C.

    2006-01-01

    The advantages of starting with simple models and building complexity slowly can be significant in the development of ground water models. In many circumstances, simpler models are characterized by fewer defined parameters and shorter execution times. In this work, the number of parameters is used as the primary measure of simplicity and complexity; the advantages of shorter execution times also are considered. The ideas are presented in the context of constructing ground water models but are applicable to many fields. Simplicity first is put in perspective as part of the entire modeling process using 14 guidelines for effective model calibration. It is noted that neither very simple nor very complex models generally produce the most accurate predictions and that determining the appropriate level of complexity is an ill-defined process. It is suggested that a thorough evaluation of observation errors is essential to model development. Finally, specific ways are discussed to design useful ground water models that have fewer parameters and shorter execution times.

  13. The effects of in-vehicle tasks and time-gap selection while reclaiming control from adaptive cruise control (ACC) with bus simulator.

    PubMed

    Lin, Tsang-Wei; Hwang, Sheue-Ling; Su, Jau-Ming; Chen, Wan-Hui

    2008-05-01

    This research aimed to find out the effects of in-vehicle distractions and time-gap settings with a fix-based bus driving simulator in a following scenario. Professional bus drivers were recruited to perform in-vehicle tasks while driving with adaptive cruise control (ACC) of changeable time-gap settings in freeway traffic. Thirty subjects were divided equally into three groups for different in-vehicle task modes (between subjects), including no task distraction, hands-free, and manual modes. Further, time-gap settings for the experimental ACC were: shorter than 1.0 s, 1.0-1.5 s, 1.5-2.0 s, and longer than 2.0 s (within subjects). Longitudinal (mean headway, forward collision rate, and response time) and lateral control (mean lateral lane position and its standard deviation) performance was assessed. In the results, longitudinal control performance was worsened by both shorter time-gaps and heavier in-vehicle tasks. But the interaction indicated that the harm by heavier in-vehicle distraction could be improved by longer time-gaps. As for the lateral control, it would only be negatively affected by shorter time-gap settings. This research indicates the effects of time-gaps and in-vehicle distraction, as well as the interaction. Proper time-gap selection under different in-vehicle distractions can help avoid accidents and keep safe.

  14. Focus on Resiliency: A Process Improvement Approach to Security Introducing the Resiliency Engineering Framework

    DTIC Science & Technology

    2006-11-06

    operational environment -1 No operational boundaries Pervasiveness of technology Expanding and rapidly changing risk profile High dependency on upstream...partners Successes are short-lived Skills have shorter longevity Less resources, more demands 5 © 2006 Carnegie Mellon University y Resiliency...involved Usually bolted on as an afterthought Security seen as technical problem Searching for magic bullet: CobiT , ITIL, ISO17799 Poorly defined and

  15. Effect of axial length on laser spot size during photodynamic therapy: an experimental study in monkeys.

    PubMed

    Kondo, Mineo; Ito, Yasuki; Miyata, Kentaro; Kondo, Nagako; Ishikawa, Kohei; Terasaki, Hiroko

    2006-01-01

    To investigate the effect of shorter axial length on the laser spot size and laser energy during photodynamic therapy (PDT) in monkeys. Experimental study with four rhesus monkeys. PDT was performed on the normal retina of monkeys whose ocular axial lengths are shorter (19.55 to 20.25 mm) than that of humans. After the PDT, the eyes were enucleated, and the diameter of the irradiated laser spot was measured with a microcaliper. The area of actual laser spot was only 0.56 to 0.61 times of the planned area, which indicated that the laser energy/area was 1.64 to 1.78 times more intense than planned initially. These results are the in vivo demonstration that the diameter of PDT laser spot is smaller for eyes with shorter axial lengths.

  16. Personality Disorder Symptom Severity Predicts Onset of Mood Episodes and Conversion to Bipolar I Disorder in Individuals with Bipolar Spectrum Disorder

    PubMed Central

    Ng, Tommy H.; Burke, Taylor A.; Stange, Jonathan P.; Walshaw, Patricia D.; Weiss, Rachel B.; Urosevic, Snezana; Abramson, Lyn Y.; Alloy, Lauren B.

    2017-01-01

    Although personality disorders (PDs) are highly comorbid with bipolar spectrum disorders (BSDs), little longitudinal research has been conducted to examine the prospective impact of PD symptoms on the course of BSDs. The aim of this study is to examine whether PD symptom severity predicts shorter time to onset of bipolar mood episodes and conversion to bipolar I disorder over time among individuals with less severe BSDs. Participants (n = 166) with bipolar II disorder, cyclothymia, or bipolar disorder not otherwise specified completed diagnostic interview assessments of PD symptoms and self-report measures of mood symptoms at baseline. They were followed prospectively with diagnostic interviews every four months for an average of 3.02 years. Cox proportional hazard regression analyses indicated that overall PD symptom severity significantly predicted shorter time to onset of hypomanic (hazard ratio [HR]= 1.42; p < .001) and major depressive episodes (HR = 1.51; p < .001) and conversion to bipolar I disorder (HR = 2.51; p < .001), after controlling for mood symptoms. Results also suggested that cluster B severity predicted shorter time to onset of hypomanic episodes (HR = 1.38; p = .002) and major depressive episodes (HR = 1.35; p = .01) and conversion to bipolar I disorder (HR = 2.77; p < .001), whereas cluster C severity (HR= 1.56; p < .001) predicted shorter time to onset of major depressive episodes. These results support predisposition models in suggesting that PD symptoms may act as a risk factor for a more severe course of BSDs. PMID:28368159

  17. Personality disorder symptom severity predicts onset of mood episodes and conversion to bipolar I disorder in individuals with bipolar spectrum disorder.

    PubMed

    Ng, Tommy H; Burke, Taylor A; Stange, Jonathan P; Walshaw, Patricia D; Weiss, Rachel B; Urosevic, Snezana; Abramson, Lyn Y; Alloy, Lauren B

    2017-04-01

    Although personality disorders (PDs) are highly comorbid with bipolar spectrum disorders (BSDs), little longitudinal research has been conducted to examine the prospective impact of PD symptoms on the course of BSDs. The aim of this study is to examine whether PD symptom severity predicts shorter time to onset of bipolar mood episodes and conversion to bipolar I disorder over time among individuals with less severe BSDs. Participants (n = 166) with bipolar II disorder, cyclothymia, or bipolar disorder not otherwise specified completed diagnostic interview assessments of PD symptoms and self-report measures of mood symptoms at baseline. They were followed prospectively with diagnostic interviews every 4 months for an average of 3.02 years. Cox proportional hazard regression analyses indicated that overall PD symptom severity significantly predicted shorter time to onset of hypomanic (hazard ratio [HR] = 1.42; p < .001) and major depressive episodes (HR = 1.51; p < .001) and conversion to bipolar I disorder (HR = 2.51; p < .001), after controlling for mood symptoms. Results also suggested that cluster B severity predicted shorter time to onset of hypomanic episodes (HR = 1.38; p = .002) and major depressive episodes (HR = 1.35; p = .01) and conversion to bipolar I disorder (HR = 2.77; p < .001), whereas cluster C severity (HR = 1.56; p < .001) predicted shorter time to onset of major depressive episodes. These results support predisposition models in suggesting that PD symptoms may act as a risk factor for a more severe course of BSDs. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. Pessimistic orientation in relation to telomere length in older men: the VA Normative Aging Study

    PubMed Central

    Ikeda, Ai; Schwartz, Joel; Peters, Junenette L.; Baccarelli, Andrea A.; Hoxha, Mirjam; Dioni, Laura; Spiro, Avron; Sparrow, David; Vokonas, Pantel; Kubzansky, Laura D.

    2014-01-01

    Background Recent research suggests pessimistic orientation is associated with shorter leukocyte telomere length (LTL). However, this is the first study to look not only at effects of pessimistic orientation on average LTL at multiple time points, but also at effects on the rate of change in LTL over time. Methods Participants were older men from the VA Normative Aging Study (n=490). The Life Orientation Test (LOT) was used to measure optimistic and pessimistic orientations at study baseline, and relative LTL by telomere to single copy gene ratio (T:S ratio) was obtained repeatedly over the course of the study (1999-2008). A total of 1,010 observations were included in the analysis. Linear mixed effect models with a random subject intercept were used to estimate associations. Results Higher pessimistic orientation scores were associated with shorter average LTL (percent difference by 1-SD increase in pessimistic orientation (95% CI): -3.08 (-5.62, -0.46)), and the finding was maintained after adjusting for the higher likelihood that healthier individuals return for follow-up visits (-3.44 (-5.95,-0.86)). However, pessimistic orientation scores were not associated with rate of change in LTL over time. No associations were found between overall optimism and optimistic orientation subscale scores and LTL. Conclusion Higher pessimistic orientation scores were associated with shorter LTL in older men. While there was no evidence that pessimistic orientation was associated with rate of change in LTL over time, higher levels of pessimistic orientation were associated with shorter LTL at baseline and this association persisted over time. PMID:24636503

  19. Comparison of open and laparoscopic preperitoneal repair of groin hernia.

    PubMed

    Li, Jianwen; Wang, Xin; Feng, Xueyi; Gu, Yan; Tang, Rui

    2013-12-01

    Compared with laparoscopic groin herniorrhaphy, the open procedure used in most former studies was Lichtenstein repair. However, unlike the totally extraperitoneal (TEP) or transabdominal preperitoneal (TAPP) laparoscopic techniques, Lichtenstein procedure is a premuscular but not preperitoneal repair. This retrospective study compared the outcomes between laparoscopic preperitoneal and open preperitoneal procedure-modified Kugel (MK) herniorrhaphy. Groin hernia patients older than 18 years who underwent open MK or laparoscopic preperitoneal herniorrhaphy in our hospitals between January 2008 and December 2010 were enrolled. Baseline characteristics, recurrence, and intraoperative, short-term, and long-term postoperative complications were recorded. Among the 1,760 included patients (530 open and 1,230 laparoscopic), 96.08% completed the follow-up (24-60 months). The patients in the open group were older than laparoscopic group (p < 0.001). More bilateral (91.45%) and recurrent (82.12%) hernia patients underwent laparoscopic procedures (p < 0.001 and p = 0.004, respectively). The overall recurrence rate was 0.71%, with no significant difference between the two approaches (p = 0.227). The overall complication rate was lower for the laparoscopic than the open approach (14.47 vs. 19.25%, p = 0.012), whereas the rates of life-threatening complications were similar (1.51 vs. 0.98%, p = 0.332). The laparoscopic group had significantly lower incidence rates of wound infection and chronic pain (p = 0.016 and p < 0.001, respectively), shorter operative time, lower visual analogue scale scores, and faster recovery than the open group (p < 0.001). As preperitoneal herniorrhaphy, both MK and laparoscopic (TEP/TAPP) procedures are safe and effective, with low incidence rates of life-threatening complications and recurrence. The laparoscopic approach is superior in terms of lower incidence rates of infection and chronic pain, shorter operative time, and faster recovery; however, careful surgical procedure selection and implementation of technical details are required.

  20. Retroperitoneal Laparoscopic Partial Nephrectomy Versus Radical Nephrectomy for Clinical T1 Renal Hilar Tumor: Comparison of Perioperative Characteristics and Short-Term Functional and Oncologic Outcomes.

    PubMed

    Yang, Chuance; Wang, Zhenlong; Huang, Shanlong; Xue, Li; Fu, Delai; Chong, Tie

    2018-04-18

    To present our single-center experience with retroperitoneal laparoscopic partial nephrectomy (LPN) and retroperitoneal laparoscopic radical nephrectomy (LRN) for T1 renal hilar tumors and evaluate which one is better. A retrospective review of 63 patients with hilar tumors undergoing retroperitoneal LPN or LRN was performed. The perioperative characteristics, change in estimated glomerular filtration rate (eGFR) from baseline to month 3, and oncologic outcomes were summarized. In total, 25 patients underwent LPN, and 38 patients underwent LRN. The mean tumor size in the LPN and LRN groups was 4.5 and 4.9 cm, respectively. The mean operation time was longer in the LPN group than that in the LRN group (212.5 minutes versus 160.7 minutes, respectively; P < .05). Patients undergoing the LPN had a longer median length of hospital stay after surgery (9 days versus 7 days, P < .05). Four percent of patients in the LPN group experienced postoperative complications compared with 5% of patients in the LRN group, which was not significantly different. Compared with preoperative eGFR, postoperative eGFR at 3 months decreased by 15.2 mL/min/1.73 m 2 and 27.8 mL/min/1.73 m 2 in the LPN and the LRN groups, respectively (P < .05). There was one local recurrence in the LPN group and three local or distant recurrences in the LRN group (P > .05). In experienced hands, although retroperitoneal LRN can result in shorter operation times and shorter lengths of stay, retroperitoneal LPN can preserve renal function better than LRN. Retroperitoneal LPN should be the priority in selected patients with T1 renal hilar tumors, especially for patients with renal insufficiency.

Top