Sample records for shorter time frames

  1. Methodological Approaches in Conducting Overviews: Current State in HTA Agencies

    ERIC Educational Resources Information Center

    Pieper, Dawid; Antoine, Sunya-Lee; Morfeld, Jana-Carina; Mathes, Tim; Eikermann, Michaela

    2014-01-01

    Objectives: Overviews search for reviews rather than for primary studies. They might have the potential to support decision making within a shorter time frame by reducing production time. We aimed to summarize available instructions for authors intending to conduct overviews as well as the currently applied methodology of overviews in…

  2. Short-Term Play Therapy for Children. Second Edition

    ERIC Educational Resources Information Center

    Kaduson, Heidi Gerard, Ed.; Schaefer, Charles E., Ed.

    2006-01-01

    Now in a thoroughly revised and updated second edition, this volume presents a variety of play approaches that facilitate children's healing in a shorter time frame. Invaluable for clinicians working within managed care and all those seeking to optimize limited time with clients, the book describes effective methods for individual, family, and…

  3. TH-A-9A-05: Initial Setup Accuracy Comparison Between Frame-Based and Frameless Stereotactic Radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tseng, T; Sheu, R; Todorov, B

    2014-06-15

    Purpose: To evaluate initial setup accuracy for stereotactic radiosurgery (SRS) between Brainlab frame-based and frameless immobilization system, also to discern the magnitude frameless system has on setup parameters. Methods: The correction shifts from the original setup were compared for total 157 SRS cranial treatments (69 frame-based vs. 88 frameless). All treatments were performed on a Novalis linac with ExacTrac positioning system. Localization box with isocenter overlay was used for initial setup and correction shift was determined by ExacTrac 6D auto-fusion to achieve submillimeter accuracy for treatment. For frameless treatments, mean time interval between simulation and treatment was 5.7 days (rangemore » 0–13). Pearson Chi-Square was used for univariate analysis. Results: The correctional radial shifts (mean±STD, median) for the frame and frameless system measured by ExacTrac were 1.2±1.2mm, 1.1mm and 3.1±3.3mm, 2.0mm, respectively. Treatments with frameless system had a radial shift >2mm more often than those with frames (51.1% vs. 2.9%; p<.0001). To achieve submillimeter accuracy, 85.5% frame-based treatments did not require shift and only 23.9% frameless treatment could succeed with initial setup. There was no statistical significant system offset observed in any direction for either system. For frameless treatments, those treated ≥ 3 days from simulation had statistically higher rates of radial shifts between 1–2mm and >2mm compared to patients treated in a shorter amount of time from simulation (34.3% and 56.7% vs. 28.6% and 33.3%, respectively; p=0.006). Conclusion: Although image-guided positioning system can also achieve submillimeter accuracy for frameless system, users should be cautious regarding the inherent uncertainty of its capability of immobilization. A proper quality assurance procedure for frameless mask manufacturing and a protocol for intra-fraction imaging verification will be crucial for frameless system. Time interval between simulation and treatment was influential to initial setup accuracy. A shorter time frame for frameless SRS treatment could be helpful in minimizing uncertainties in localization.« less

  4. 75 FR 22884 - Self-Regulatory Organizations; NYSE Arca, Inc.; Notice of Filing and Immediate Effectiveness of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-30

    ... uniform time frame for the introduction of new LEAPS on equity option classes, options on exchange traded... minimum volume threshold per underlying class to qualify for the introduction of a new expiration year of... 30 days from the date on which it was filed, or such shorter time as the Commission may designate if...

  5. Three Accelerated Developmental Education Programs: Features, Student Outcomes, and Implications

    ERIC Educational Resources Information Center

    Jaggars, Shanna Smith; Hodara, Michelle; Cho, Sung-Woo; Xu, Di

    2015-01-01

    To support the long-term success of underprepared students, many community colleges are experimenting with accelerated developmental education models, which allow students to complete remediation and enroll in college-level math and English within a shorter time frame. This study examines three developmental acceleration programs, including two in…

  6. Short-Term Play Therapy for Children.

    ERIC Educational Resources Information Center

    Kaduson, Heidi Gerard, Ed.; Schaefer, Charles E., Ed.

    Play therapy offers a powerful means of helping children resolve a wide range of psychological difficulties, and many play approaches are ideally suited to short-term work. This book brings together leading play therapists to share their expertise on facilitating children's healing in a shorter time frame. The book provides knowledge and skills…

  7. Non-random temporary emigration and the robust design: Conditions for bias at the end of a time series: Section VIII

    USGS Publications Warehouse

    Langtimm, Catherine A.

    2008-01-01

    Knowing the extent and magnitude of the potential bias can help in making decisions as to what time frame provides the best estimates or the most reliable opportunity to model and test hypotheses about factors affecting survival probability. To assess bias, truncating the capture histories to shorter time frames and reanalyzing the data to compare time-specific estimates may help identify spurious effects. Running simulations that mimic the parameter values and movement conditions in the real situation can provide estimates of standardized bias that can be used to identify those annual estimates that are biased to the point where the 95% confidence intervals are inadequate in describing the uncertainty of the estimates.

  8. Regional Environmental Monitoring and Assessment Program Data (REMAP)

    EPA Pesticide Factsheets

    The Regional Environmental Monitoring and Assessment Program (REMAP) was initiated to test the applicability of the Environmental Monitoring and Assessment Program (EMAP) approach to answer questions about ecological conditions at regional and local scales. Using EMAP's statistical design and indicator concepts, REMAP conducts projects at smaller geographic scales and in shorter time frames than the national EMAP program.

  9. Real-time processing for full-range Fourier-domain optical-coherence tomography with zero-filling interpolation using multiple graphic processing units.

    PubMed

    Watanabe, Yuuki; Maeno, Seiya; Aoshima, Kenji; Hasegawa, Haruyuki; Koseki, Hitoshi

    2010-09-01

    The real-time display of full-range, 2048?axial pixelx1024?lateral pixel, Fourier-domain optical-coherence tomography (FD-OCT) images is demonstrated. The required speed was achieved by using dual graphic processing units (GPUs) with many stream processors to realize highly parallel processing. We used a zero-filling technique, including a forward Fourier transform, a zero padding to increase the axial data-array size to 8192, an inverse-Fourier transform back to the spectral domain, a linear interpolation from wavelength to wavenumber, a lateral Hilbert transform to obtain the complex spectrum, a Fourier transform to obtain the axial profiles, and a log scaling. The data-transfer time of the frame grabber was 15.73?ms, and the processing time, which includes the data transfer between the GPU memory and the host computer, was 14.75?ms, for a total time shorter than the 36.70?ms frame-interval time using a line-scan CCD camera operated at 27.9?kHz. That is, our OCT system achieved a processed-image display rate of 27.23 frames/s.

  10. 36 CFR 1254.92 - How do I submit a request to microfilm records and donated historical materials?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., records preparation, and other NARA requirements in a shorter time frame. (1) You may include in your request only one project to microfilm a complete body of documents, such as an entire series, a major continuous segment of a very large series which is reasonably divisible, or a limited number of separate...

  11. 36 CFR 1254.92 - How do I submit a request to microfilm records and donated historical materials?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., records preparation, and other NARA requirements in a shorter time frame. (1) You may include in your request only one project to microfilm a complete body of documents, such as an entire series, a major continuous segment of a very large series which is reasonably divisible, or a limited number of separate...

  12. Asymmetry in gait pattern following bicondylar tibial plateau fractures-A prospective one-year cohort study.

    PubMed

    Elsoe, Rasmus; Larsen, Peter

    2017-07-01

    Despite the high number of studies evaluating outcomes following tibial plateau fractures, the literature lacks studies including the objective assessment of gait pattern. The purpose of the present study was to evaluate asymmetry in gait patterns at 12 months after frame removal following ring fixation of a tibial plateau fracture. The study design was a prospective cohort study. The primary outcome measurement was the gait patterns 12 months after frame removal measured with a pressure-sensitive mat. The mat registers footprints and present gait speed, cadence, as well as temporal and spatial parameters of the gait cycle. Gait patterns were compared to a healthy reference population. Twenty-three patients were included with a mean age of 54.4 years (32-78 years). Patients presented with a shorter step-length of the injured leg compared to the non-injured leg (asymmetry of 11.3%). Analysis of single-support showed shorter support time of the injured leg compared to the non-injured leg (asymmetry of 8.7%). Moreover, analysis of swing-time showed increased swing-time of the injured leg (asymmetry of 8.9%). Compared to a healthy reference population, increased asymmetry in all gait patterns was observed. The association between asymmetry and health-related quality of life (HRQOL) showed moderate associations (single-support: R=0.50, P=0.03; step-length: R=0.43, P=0.07; swing-time: R=0.46, P=0.05). Compared to a healthy reference population, gait asymmetry is common 12 months after frame removal in patients treated with external ring fixation following a tibial plateau fracture of the tibia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Translation, modification and cellular distribution of two AC4 variants of African cassava mosaic virus in yeast and their pathogenic potential in plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hipp, Katharina, E-mail: katharina.hipp@bio.uni-st

    Plant infecting geminiviruses encode a small (A)C4 protein within the open reading frame of the replication-initiator protein. In African cassava mosaic virus, two in-frame start codons may be used for the translation of a longer and a shorter AC4 variant. Both were fused to green fluorescent protein or glutathione-S-transferase genes and expressed in fission yeast. The longer variant accumulated in discrete spots in the cytoplasm, whereas the shorter variant localized to the plasma membrane. A similar expression pattern was found in plants. A myristoylation motif may promote a targeting of the shorter variant to the plasma membrane. Mass spectrometry analysismore » of the yeast-expressed shorter variant detected the corresponding myristoylation. The biological relevance of the second start codon was confirmed using mutated infectious clones. Whereas mutating the first start codon had no effect on the infectivity in Nicotiana benthamiana plants, the second start codon proved to be essential. -- Highlights: •The ACMV AC4 may be translated from one or the other in-frame start codon. •Both AC4 variants are translated in fission yeast. •The long AC4 protein localizes to the cytoplasm, the short to the plasma membrane. •The short variant is myristoylated in yeast and may promote membrane localization. •Only the shorter AC4 variant has an impact on viral infections in plants.« less

  14. Cheetah: A high frame rate, high resolution SWIR image camera

    NASA Astrophysics Data System (ADS)

    Neys, Joel; Bentell, Jonas; O'Grady, Matt; Vermeiren, Jan; Colin, Thierry; Hooylaerts, Peter; Grietens, Bob

    2008-10-01

    A high resolution, high frame rate InGaAs based image sensor and associated camera has been developed. The sensor and the camera are capable of recording and delivering more than 1700 full 640x512pixel frames per second. The FPA utilizes a low lag CTIA current integrator in each pixel, enabling integration times shorter than one microsecond. On-chip logics allows for four different sub windows to be read out simultaneously at even higher rates. The spectral sensitivity of the FPA is situated in the SWIR range [0.9-1.7 μm] and can be further extended into the Visible and NIR range. The Cheetah camera has max 16 GB of on-board memory to store the acquired images and transfer the data over a Gigabit Ethernet connection to the PC. The camera is also equipped with a full CameralinkTM interface to directly stream the data to a frame grabber or dedicated image processing unit. The Cheetah camera is completely under software control.

  15. How consumers are affected by product descriptions in online shopping: Event-related potentials evidence of the attribute framing effect.

    PubMed

    Jin, Jia; Zhang, Wuke; Chen, Mingliang

    2017-12-01

    Due to the limitations of the human ability to process information, e-consumers' decisions are likely to be influenced by various cognitive biases, such as the attribute framing effect. This effect has been well studied by numerous scholars; however, the associated underlying neural mechanisms with a critical temporal resolution have not been revealed. Thus, this study applies the measurement of event-related potentials (ERPs) to directly examine the role of attribute framing in information processing and decision-making in online shopping. The behavioral results showed that participants demonstrated a higher purchase intention with a shorter reaction time under a positive framing condition compared to participants under a negative framing condition. Compared with positive framing messages, the results of ERPs indicated that negative framing messages attracted more attention resources at the early stage of rapid automatic processing (larger P2 amplitude) and resulted in greater cognitive conflict and decision difficulty (larger P2-N2 complex). Moreover, compared with negative messages, positive framing messages allowed consumers to perceive a better future performance of products and classify these products as a categorization of higher evaluation (larger LPP amplitude) at the late cognitive processing stage of evaluation. Based on these results, we provide evidence for a better understanding of how different attribute framing messages are processed and ultimately lead to the framing effect. Copyright © 2017 Elsevier Ireland Ltd and Japan Neuroscience Society. All rights reserved.

  16. Effect of drug-related cues on response inhibition through abstinence: A pilot study in male heroin abstainers.

    PubMed

    Su, Bobo; Yang, Ling; Wang, Grace Y; Wang, Sha; Li, Shaomei; Cao, Hua; Zhang, Yan

    2017-11-01

    Chronic heroin use can cause a deficit of inhibitory function, leading to a loss of control over drug use. Exposure to drug-related cues is considered as one of the contributing factors. However, it is unclear whether there are dynamic changes on the effect of drug-related cues on response inhibition following prolonged abstinence. The present study investigated the effect of drug-related cues on response inhibition in heroin abstainers at different abstinent phases. 26 shorter-term (2-6 months) and 26 longer-term (19-24 months) male heroin abstainers performed on a modified two-choice Oddball task, which included two conditions: in the cued condition, neutral pictures served as the background of standard stimuli (yellow frame) and heroin-related pictures served as the background of deviant stimuli (blue frame), reversed in the controlled conditions. Compared to longer-term abstainers, mean reaction time (RT) for drug deviants in shorter-term abstainers was significantly longer. Shorter-term abstainers also showed markedly slower response to neutral deviants relative to drug deviants, but this tendency was not observed in longer-term abstainers. Nevertheless, both groups had similar RT for standard stimuli regardless of their paired background pictures. Effect of drug-related cues on response inhibition remains at the early stage of abstinence; however, this effect may be reduced following a longer period of drug abstinence. Our findings highlight the importance of assessing and improving the ability of inhibiting drug-related cue reactivity during treatment.

  17. Annual Geocenter Motion from Space Geodesy and Models

    NASA Astrophysics Data System (ADS)

    Ries, J. C.

    2013-12-01

    Ideally, the origin of the terrestrial reference frame and the center of mass of the Earth are always coincident. By construction, the origin of the reference frame is coincident with the mean Earth center of mass, averaged over the time span of the satellite laser ranging (SLR) observations used in the reference frame solution, within some level of uncertainty. At shorter time scales, tidal and non-tidal mass variations result in an offset between the origin and geocenter, called geocenter motion. Currently, there is a conventional model for the tidally-coherent diurnal and semi-diurnal geocenter motion, but there is no model for the non-tidal annual variation. This annual motion reflects the largest-scale mass redistribution in the Earth system, so it essential to observe it for a complete description of the total mass transport. Failing to model it can also cause false signals in geodetic products such as sea height observations from satellite altimeters. In this paper, a variety of estimates for the annual geocenter motion are presented based on several different geodetic techniques and models, and a ';consensus' model from SLR is suggested.

  18. Eye pupil detection system using an ensemble of regression forest and fast radial symmetry transform with a near infrared camera

    NASA Astrophysics Data System (ADS)

    Jeong, Mira; Nam, Jae-Yeal; Ko, Byoung Chul

    2017-09-01

    In this paper, we focus on pupil center detection in various video sequences that include head poses and changes in illumination. To detect the pupil center, we first find four eye landmarks in each eye by using cascade local regression based on a regression forest. Based on the rough location of the pupil, a fast radial symmetric transform is applied using the previously found pupil location to rearrange the fine pupil center. As the final step, the pupil displacement is estimated between the previous frame and the current frame to maintain the level of accuracy against a false locating result occurring in a particular frame. We generated a new face dataset, called Keimyung University pupil detection (KMUPD), with infrared camera. The proposed method was successfully applied to the KMUPD dataset, and the results indicate that its pupil center detection capability is better than that of other methods and with a shorter processing time.

  19. TEMPORAL EVOLUTION AND SPATIAL DISTRIBUTION OF WHITE-LIGHT FLARE KERNELS IN A SOLAR FLARE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawate, T.; Ishii, T. T.; Nakatani, Y.

    2016-12-10

    On 2011 September 6, we observed an X2.1-class flare in continuum and H α with a frame rate of about 30 Hz. After processing images of the event by using a speckle-masking image reconstruction, we identified white-light (WL) flare ribbons on opposite sides of the magnetic neutral line. We derive the light curve decay times of the WL flare kernels at each resolution element by assuming that the kernels consist of one or two components that decay exponentially, starting from the peak time. As a result, 42% of the pixels have two decay-time components with average decay times of 15.6 andmore » 587 s, whereas the average decay time is 254 s for WL kernels with only one decay-time component. The peak intensities of the shorter decay-time component exhibit good spatial correlation with the WL intensity, whereas the peak intensities of the long decay-time components tend to be larger in the early phase of the flare at the inner part of the flare ribbons, close to the magnetic neutral line. The average intensity of the longer decay-time components is 1.78 times higher than that of the shorter decay-time components. If the shorter decay time is determined by either the chromospheric cooling time or the nonthermal ionization timescale and the longer decay time is attributed to the coronal cooling time, this result suggests that WL sources from both regions appear in 42% of the WL kernels and that WL emission of the coronal origin is sometimes stronger than that of chromospheric origin.« less

  20. Quicker, faster, darker: Changes in Hollywood film over 75 years

    PubMed Central

    Cutting, James E; Brunick, Kaitlin L; DeLong, Jordan E; Iricinschi, Catalina; Candan, Ayse

    2011-01-01

    We measured 160 English-language films released from 1935 to 2010 and found four changes. First, shot lengths have gotten shorter, a trend also reported by others. Second, contemporary films have more motion and movement than earlier films. Third, in contemporary films shorter shots also have proportionately more motion than longer shots, whereas there is no such relation in older films. And finally films have gotten darker. That is, the mean luminance value of frames across the length of a film has decreased over time. We discuss psychological effects associated with these four changes and suggest that all four linear trends have a single cause: Filmmakers have incrementally tried to exercise more control over the attention of filmgoers. We suggest these changes are signatures of the evolution of popular film; they do not reflect changes in film style. PMID:23145246

  1. Infections of the developing world.

    PubMed

    Murthy, Srinivas; Keystone, Jay; Kissoon, Niranjan

    2013-07-01

    Access to critical care is rapidly growing in areas of the world where it was previously nonexistent and where infectious diseases often comprise the largest disease burden. Additionally, with crowding, mass migrations, and air travel, infectious diseases previously geographically confined are quickly spread across the planet, often in shorter time frames than disease incubation periods. Hence, critical care practitioners must be familiar with infectious diseases previously confined to the developing world. This article reviews selected tropical diseases that are seen in diverse locales and often require critical care services. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. EIGER detector: application in macromolecular crystallography.

    PubMed

    Casanas, Arnau; Warshamanage, Rangana; Finke, Aaron D; Panepucci, Ezequiel; Olieric, Vincent; Nöll, Anne; Tampé, Robert; Brandstetter, Stefan; Förster, Andreas; Mueller, Marcus; Schulze-Briese, Clemens; Bunk, Oliver; Wang, Meitian

    2016-09-01

    The development of single-photon-counting detectors, such as the PILATUS, has been a major recent breakthrough in macromolecular crystallography, enabling noise-free detection and novel data-acquisition modes. The new EIGER detector features a pixel size of 75 × 75 µm, frame rates of up to 3000 Hz and a dead time as low as 3.8 µs. An EIGER 1M and EIGER 16M were tested on Swiss Light Source beamlines X10SA and X06SA for their application in macromolecular crystallography. The combination of fast frame rates and a very short dead time allows high-quality data acquisition in a shorter time. The ultrafine ϕ-slicing data-collection method is introduced and validated and its application in finding the optimal rotation angle, a suitable rotation speed and a sufficient X-ray dose are presented. An improvement of the data quality up to slicing at one tenth of the mosaicity has been observed, which is much finer than expected based on previous findings. The influence of key data-collection parameters on data quality is discussed.

  3. Limb Lengthening and Then Insertion of an Intramedullary Nail: A Case-matched Comparison

    PubMed Central

    Kleinman, Dawn; Fragomen, Austin T.; Ilizarov, Svetlana

    2008-01-01

    Distraction osteogenesis is an effective method for lengthening, deformity correction, and treatment of nonunions and bone defects. The classic method uses an external fixator for both distraction and consolidation leading to lengthy times in frames and there is a risk of refracture after frame removal. We suggest a new technique: lengthening and then nailing (LATN) technique in which the frame is used for gradual distraction and then a reamed intramedullary nail inserted to support the bone during the consolidation phase, allowing early removal of the external fixator. We performed a retrospective case-matched comparison of patients lengthened with LATN (39 limbs in 27 patients) technique versus the classic (34 limbs in 27 patients). The LATN group wore the external fixator for less time than the classic group (12 versus 29 weeks). The LATN group had a lower external fixation index (0.5 versus 1.9) and a lower bone healing index (0.8 versus 1.9) than the classic group. LATN confers advantages over the classic method including shorter times needed in external fixation, quicker bone healing, and protection against refracture. There are also advantages over the lengthening over a nail and internal lengthening nail techniques. Level of Evidence: Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18800209

  4. The Temptation of Zero Price: Event-Related Potentials Evidence of How Price Framing Influences the Purchase of Bundles.

    PubMed

    Ma, Haiying; Mo, Zan; Zhang, Huijun; Wang, Cuicui; Fu, Huijian

    2018-01-01

    Studies have revealed that consumers are susceptible to price framing effect, a common cognitive bias, due to their limited capacity in processing information. The effect of price framing in a bundling context and its neural correlates, however, remain not clearly characterized. The present study applied the event-related potentials (ERPs) approach to investigate the role of price framing in information processing and purchase decision making in a bundling context. Three price frames were created with practically identical total prices (with a maximum difference of ¥0.1, which was about equal to 0.016 US dollars) for a bundle with two components, a focal product and a tie-in product. In normal price condition (NP), both the focal and tie-in products were offered at a normal discounted price; in zero price condition (ZP), the tie-in product was offered free while the total price of the bundle remained the same as NP; whereas in low price condition (LP), the tie-in product was offered at a low token price (¥0.1), and the focal product shared the same price as the focal product of ZP. The behavioral results showed a higher purchase rate and a shorter reaction time for ZP in contrast to NP. Neurophysiologically, enlarged LPP amplitude was elicited by ZP relative to NP, suggesting that ZP triggered a stronger positive affect that could motivate decision to buy. Thus, this study provides both behavioral and neural evidence for how different price framing information is processed and ultimately gives rise to price framing effect in purchase decision making.

  5. Fuel cell manifold sealing system

    DOEpatents

    Grevstad, Paul E.; Johnson, Carl K.; Mientek, Anthony P.

    1980-01-01

    A manifold-to-stack seal and sealing method for fuel cell stacks. This seal system solves the problem of maintaining a low leak rate manifold seal as the fuel cell stack undergoes compressive creep. The seal system eliminates the problem of the manifold-to-stack seal sliding against the rough stack surface as the stack becomes shorter because of cell creep, which relative motion destroys the seal. The seal system described herein utilizes a polymer seal frame firmly clamped between the manifold and the stack such that the seal frame moves with the stack. Thus, as the stack creeps, the seal frame creeps with it, and there is no sliding at the rough, tough to seal, stack-to-seal frame interface. Here the sliding is on a smooth easy to seal location between the seal frame and the manifold.

  6. Method for producing a fuel cell manifold seal

    DOEpatents

    Grevstad, Paul E.; Johnson, Carl K.; Mientek, Anthony P.

    1982-01-01

    A manifold-to-stack seal and sealing method for fuel cell stacks. This seal system solves the problem of maintaining a low leak rate manifold seal as the fuel cell stack undergoes compressive creep. The seal system eliminates the problem of the manifold-to-stack seal sliding against the rough stack surface as the stack becomes shorter because of cell creep, which relative motion destroys the seal. The seal system described herein utilizes a polymer seal frame firmly clamped between the manifold and the stack such that the seal frame moves with the stack. Thus, as the stack creeps, the seal frame creeps with it, and there is no sliding at the rough, tough to seal, stack-to-seal frame interface. Here the sliding is on a smooth easy to seal location between the seal frame and the manifold.

  7. High-speed varifocal imaging with a tunable acoustic gradient index of refraction lens.

    PubMed

    Mermillod-Blondin, Alexandre; McLeod, Euan; Arnold, Craig B

    2008-09-15

    Fluidic lenses allow for varifocal optical elements, but current approaches are limited by the speed at which focal length can be changed. Here we demonstrate the use of a tunable acoustic gradient (TAG) index of refraction lens as a fast varifocal element. The optical power of the TAG lens varies continuously, allowing for rapid selection and modification of the effective focal length at time scales of 1 mus and shorter. The wavefront curvature applied to the incident light is experimentally quantified as a function of time, and single-frame imaging is demonstrated. Results indicate that the TAG lens can successfully be employed to perform high-rate imaging at multiple locations.

  8. Frameless robot-assisted stereoelectroencephalography in children: technical aspects and comparison with Talairach frame technique.

    PubMed

    Abel, Taylor J; Varela Osorio, René; Amorim-Leite, Ricardo; Mathieu, Francois; Kahane, Philippe; Minotti, Lorella; Hoffmann, Dominique; Chabardes, Stephan

    2018-04-20

    OBJECTIVE Robot-assisted stereoelectroencephalography (SEEG) is gaining popularity as a technique for localization of the epileptogenic zone (EZ) in children with pharmacoresistant epilepsy. Here, the authors describe their frameless robot-assisted SEEG technique and report preliminary outcomes and relative complications in children as compared to results with the Talairach frame-based SEEG technique. METHODS The authors retrospectively analyzed the results of 19 robot-assisted SEEG electrode implantations in 17 consecutive children (age < 17 years) with pharmacoresistant epilepsy, and compared these results to 19 preceding SEEG electrode implantations in 18 children who underwent the traditional Talairach frame-based SEEG electrode implantation. The primary end points were seizure-freedom rates, operating time, and complication rates. RESULTS Seventeen children (age < 17 years) underwent a total of 19 robot-assisted SEEG electrode implantations. In total, 265 electrodes were implanted. Twelve children went on to have EZ resection: 4 demonstrated Engel class I outcomes, whereas 2 had Engel class II outcomes, and 6 had Engel class III-IV outcomes. Of the 5 patients who did not have resection, 2 underwent thermocoagulation. One child reported transient paresthesia associated with 2 small subdural hematomas, and 3 other children had minor asymptomatic intracranial hemorrhages. There were no differences in complication rates, rates of resective epilepsy surgery, or seizure freedom rates between this cohort and the preceding 18 children who underwent Talairach frame-based SEEG. The frameless robot-assisted technique was associated with shorter operating time (p < 0.05). CONCLUSIONS Frameless robot-assisted SEEG is a safe and effective means of identifying the EZ in children with pharmacoresistant partial epilepsy. Robot-assisted SEEG is faster than the Talairach frame-based method, and has equivalent safety and efficacy. The former, furthermore, facilitates more electrode trajectory possibilities, which may improve the localization of epileptic networks.

  9. The Temptation of Zero Price: Event-Related Potentials Evidence of How Price Framing Influences the Purchase of Bundles

    PubMed Central

    Ma, Haiying; Mo, Zan; Zhang, Huijun; Wang, Cuicui; Fu, Huijian

    2018-01-01

    Studies have revealed that consumers are susceptible to price framing effect, a common cognitive bias, due to their limited capacity in processing information. The effect of price framing in a bundling context and its neural correlates, however, remain not clearly characterized. The present study applied the event-related potentials (ERPs) approach to investigate the role of price framing in information processing and purchase decision making in a bundling context. Three price frames were created with practically identical total prices (with a maximum difference of ¥0.1, which was about equal to 0.016 US dollars) for a bundle with two components, a focal product and a tie-in product. In normal price condition (NP), both the focal and tie-in products were offered at a normal discounted price; in zero price condition (ZP), the tie-in product was offered free while the total price of the bundle remained the same as NP; whereas in low price condition (LP), the tie-in product was offered at a low token price (¥0.1), and the focal product shared the same price as the focal product of ZP. The behavioral results showed a higher purchase rate and a shorter reaction time for ZP in contrast to NP. Neurophysiologically, enlarged LPP amplitude was elicited by ZP relative to NP, suggesting that ZP triggered a stronger positive affect that could motivate decision to buy. Thus, this study provides both behavioral and neural evidence for how different price framing information is processed and ultimately gives rise to price framing effect in purchase decision making. PMID:29731705

  10. Relationship between selected orientation rest frame, circular vection and space motion sickness

    NASA Technical Reports Server (NTRS)

    Harm, D. L.; Parker, D. E.; Reschke, M. F.; Skinner, N. C.

    1998-01-01

    Space motion sickness (SMS) and spatial orientation and motion perception disturbances occur in 70-80% of astronauts. People select "rest frames" to create the subjective sense of spatial orientation. In microgravity, the astronaut's rest frame may be based on visual scene polarity cues and on the internal head and body z axis (vertical body axis). The data reported here address the following question: Can an astronaut's orientation rest frame be related and described by other variables including circular vection response latencies and space motion sickness? The astronaut's microgravity spatial orientation rest frames were determined from inflight and postflight verbal reports. Circular vection responses were elicited by rotating a virtual room continuously at 35 degrees/s in pitch, roll and yaw with respect to the astronaut. Latency to the onset of vection was recorded from the time the crew member opened their eyes to the onset of vection. The astronauts who used visual cues exhibited significantly shorter vection latencies than those who used internal z axis cues. A negative binomial regression model was used to represent the observed total SMS symptom scores for each subject for each flight day. Orientation reference type had a significant effect, resulting in an estimated three-fold increase in the expected motion sickness score on flight day 1 for astronauts who used visual cues. The results demonstrate meaningful classification of astronauts' rest frames and their relationships to sensitivity to circular vection and SMS. Thus, it may be possible to use vection latencies to predict SMS severity and duration.

  11. The effects of intermittent illumination on a visual inspection task.

    PubMed

    Kennedy, A; Brysbaert, M; Murray, W S

    1998-02-01

    Two experiments are described in which eye movements were monitored as subjects performed a simple target-spotting task under conditions of intermittent illumination produced by varying the display-screen frame rate on a computer VDU. In Experiment 1, subjects executed a saccade from a fixation point to a target which appeared randomly at a fixed eccentricity of 14 character positions to the left or right. Saccade latency did not differ reliably as a function of screen refresh rate, but average saccade extent at 70 Hz and 110 Hz was reliably shorter than at 90 Hz and 100 Hz. Experiment 2 examined the same task using a range of target eccentricities (7, 14, and 28 character positions to the left and right) and across a wider range of screen refresh rates. The results confirmed the curvilinear relationship obtained in Experiment 1, with average saccade extent reliably shorter at refresh rates of 50 Hz and 125 Hz than at 75 Hz and 100 Hz. While the effect was greater for remote targets, analyses of the proportional target error failed to show a reliable interaction between target eccentricity and display refresh rate. In contrast to Experiment 1, there was a pronounced effect of refresh rate on saccade latency (corrected for time to write the screen frame), with shorter latencies at higher refresh rates. It may be concluded that pulsation at frequencies above fusion disrupts saccade control. However, the curvilinear functional relationship between screen refresh rate and saccade extent obtained in these studies differs from previously reported effects of intermittent illumination on the average size of "entry saccades" (the first saccade to enter a given word) in a task involving word identification (Kennedy & Murray, 1993a, 1996). This conflict of data may arise in part because within-word adjustments in viewing position, which are typical of normal reading, influence measures of average saccade extent.

  12. Pilot production system cost/benefit analysis: Digital document storage project

    NASA Technical Reports Server (NTRS)

    1989-01-01

    The Digital Document Storage (DDS)/Pilot Production System (PPS) will provide cost effective electronic document storage, retrieval, hard copy reproduction, and remote access for users of NASA Technical Reports. The DDS/PPS will result in major benefits, such as improved document reproduction quality within a shorter time frame than is currently possible. In addition, the DDS/PPS will provide an important strategic value through the construction of a digital document archive. It is highly recommended that NASA proceed with the DDS Prototype System and a rapid prototyping development methodology in order to validate recent working assumptions upon which the success of the DDS/PPS is dependent.

  13. A novel rotational matrix and translation vector algorithm: geometric accuracy for augmented reality in oral and maxillofacial surgeries.

    PubMed

    Murugesan, Yahini Prabha; Alsadoon, Abeer; Manoranjan, Paul; Prasad, P W C

    2018-06-01

    Augmented reality-based surgeries have not been successfully implemented in oral and maxillofacial areas due to limitations in geometric accuracy and image registration. This paper aims to improve the accuracy and depth perception of the augmented video. The proposed system consists of a rotational matrix and translation vector algorithm to reduce the geometric error and improve the depth perception by including 2 stereo cameras and a translucent mirror in the operating room. The results on the mandible/maxilla area show that the new algorithm improves the video accuracy by 0.30-0.40 mm (in terms of overlay error) and the processing rate to 10-13 frames/s compared to 7-10 frames/s in existing systems. The depth perception increased by 90-100 mm. The proposed system concentrates on reducing the geometric error. Thus, this study provides an acceptable range of accuracy with a shorter operating time, which provides surgeons with a smooth surgical flow. Copyright © 2018 John Wiley & Sons, Ltd.

  14. Judgment and judgment latency for freedom and responsibility relatedness as a function of subtle linguistic variations.

    PubMed

    Wilkerson, Keith; McGahan, Joseph R; Stevens, Rick; Williamson, David; Low, Jean

    2009-12-01

    The goal of this study was to determine whether differential response formats to covariation problems influence corresponding response latencies. The authors provided participants with 3 trials of 16 statements addressing positive and negative relations between freedom and responsibility. The authors framed half of the items around responsibility given freedom and the other half around freedom given responsibility. Response formats comprised true-false, agree-disagree, and yes-no answers as a between-participants factor. Results indicated that the manipulation of response format did not affect latencies. However, latencies differed according to the framing of the items. For items framed around freedom given responsibility, latencies were shorter. In addition, participants were more likely to report a positive relation between freedom and responsibility when items were framed around freedom given responsibility. The authors discuss implications relative to previous research in this area and give recommendations for future research.

  15. FDDI network test adaptor error injection circuit

    NASA Technical Reports Server (NTRS)

    Eckenrode, Thomas (Inventor); Stauffer, David R. (Inventor); Stempski, Rebecca (Inventor)

    1994-01-01

    An apparatus for injecting errors into a FDDI token ring network is disclosed. The error injection scheme operates by fooling a FORMAC into thinking it sent a real frame of data. This is done by using two RAM buffers. The RAM buffer normally accessed by the RBC/DPC becomes a SHADOW RAM during error injection operation. A dummy frame is loaded into the shadow RAM in order to fool the FORMAC. This data is just like the data that would be used if sending a normal frame, with the restriction that it must be shorter than the error injection data. The other buffer, the error injection RAM, contains the error injection frame. The error injection data is sent out to the media by switching a multiplexor. When the FORMAC is done transmitting the data, the multiplexor is switched back to the normal mode. Thus, the FORMAC is unaware of what happened and the token ring remains operational.

  16. Revisiting black holes and wormholes under Weyl transformations

    NASA Astrophysics Data System (ADS)

    Hammad, Fayçal

    2018-06-01

    The behavior of black hole horizons and wormholes under the Weyl conformal transformation is investigated. First, a shorter (but more general) derivation of the Weyl transformation of the simple prescription for detecting horizons and wormholes given recently in the literature for spherically symmetric spacetimes is provided. The derivation allows for a simple and intuitive way to understand why and when horizons and wormholes might arise in the conformal frame even if they were absent in the original frame. Then, the conformal behavior of black holes horizon and wormholes in more general spacetimes, based on more "sophisticated" definitions, is provided. The study shows that black holes and wormholes might always arise in the new frame even if they were absent in the original frame. Moreover, it is shown that some of the definitions found in the literature might be transformed into one another under such transformations. Worked-out examples are given.

  17. Methodological approaches in conducting overviews: current state in HTA agencies.

    PubMed

    Pieper, Dawid; Antoine, Sunya-Lee; Morfeld, Jana-Carina; Mathes, Tim; Eikermann, Michaela

    2014-09-01

    Overviews search for reviews rather than for primary studies. They might have the potential to support decision making within a shorter time frame by reducing production time. We aimed to summarize available instructions for authors intending to conduct overviews as well as the currently applied methodology of overviews in international Health Technology Assessment (HTA) agencies. We identified 127 HTA agencies and scanned their websites for methodological handbooks as well as published overviews as HTA reports. Additionally, we contacted HTA agencies by e-mail to retrieve possible unidentified handbooks or other related sources. In total, eight HTA agencies providing methodological support were found. Thirteen HTA agencies were found to have produced overviews since 2007, but only six of them published more than four overviews. Overviews were mostly employed in HTA products related to rapid assessment. Additional searches for primary studies published after the last review are often mentioned in order to update results. Although the interest in overviews is rising, little methodological guidance for the conduct of overviews is provided by HTA agencies. Overviews are of special interest in the context of rapid assessments to support policy-making within a short time frame. Therefore, empirical work on overviews needs to be extended. National strategies and experience should be disclosed and discussed. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Gaussian mixture models as flux prediction method for central receivers

    NASA Astrophysics Data System (ADS)

    Grobler, Annemarie; Gauché, Paul; Smit, Willie

    2016-05-01

    Flux prediction methods are crucial to the design and operation of central receiver systems. Current methods such as the circular and elliptical (bivariate) Gaussian prediction methods are often used in field layout design and aiming strategies. For experimental or small central receiver systems, the flux profile of a single heliostat often deviates significantly from the circular and elliptical Gaussian models. Therefore a novel method of flux prediction was developed by incorporating the fitting of Gaussian mixture models onto flux profiles produced by flux measurement or ray tracing. A method was also developed to predict the Gaussian mixture model parameters of a single heliostat for a given time using image processing. Recording the predicted parameters in a database ensures that more accurate predictions are made in a shorter time frame.

  19. Recent advances in a linear micromirror array for high-resolution projection

    NASA Astrophysics Data System (ADS)

    Picard, Francis; Doucet, Michel; Niall, Keith K.; Larouche, Carl; Savard, Maxime; Crisan, Silviu; Thibault, Simon; Jerominek, Hubert

    2004-05-01

    The visual displays of contemporary military flight simulators lack adequate definition to represent scenes in basic fast-jet fighter tasks. For example, air-to-air and air-to-ground targets are not projected with sufficient contrast and resolution for a pilot to perceive aspect, aspect rate and object detail at real world slant ranges. Simulator display geometries require the development of ultra-high resolution projectors with greater than 20 megapixel resolution at 60 Hz frame rate. A new micromirror device has been developed to address this requirement; it is able to modulate light intensity in an analog fashion with switching times shorter than 5 μs. When combined with a scanner, a laser and Schlieren optics, a linear array of these flexible micromirrors can display images composed of thousands of lines at a frame rate of 60 Hz. Recent results related to evaluation of this technology for high resolution projection are presented. Alternate operation modes for light modulation with flexible micromirrors are proposed. The related importance of controlling the residual micromirror curvature is discussed and results of experiments investigating the use of the deposition pressure to achieve such control are reported. Moreover, activities aiming at minimizing the micromirror response time and, so doing, maximizing the number of image columns per image frame are discussed. Finally, contrast measurement and estimate of the contrast limit achievable with the flexible micromirror technology are presented. All reported activities support the development of a fully addressable 2000-element micromirror array.

  20. Length estimations of presumed upward connecting leaders in lightning flashes to flat water and flat ground

    NASA Astrophysics Data System (ADS)

    Stolzenburg, Maribeth; Marshall, Thomas C.; Karunarathne, Sumedhe; Orville, Richard E.

    2018-10-01

    Using video data recorded at 50,000 frames per second for nearby negative lightning flashes, estimates are derived for the length of positive upward connecting leaders (UCLs) that presumably formed prior to new ground attachments. Return strokes were 1.7 to 7.8 km distant, yielding image resolutions of 4.25 to 19.5 m. No UCLs are imaged in these data, indicating those features were too transient or too dim compared to other lightning processes that are imaged at these resolutions. Upper bound lengths for 17 presumed UCLs are determined from the height above flat ground or water of the successful stepped leader tip in the image immediately prior to (within 20 μs before) the return stroke. Better estimates of maximum UCL lengths are determined using the downward stepped leader tip's speed of advance and the estimated return stroke time within its first frame. For 17 strokes, the upper bound length of the possible UCL averages 31.6 m and ranges from 11.3 to 50.3 m. Among the close strokes (those with spatial resolution <8 m per pixel), the five which connected to water (salt water lagoon) have UCL upper bound estimates averaging significantly shorter (24.1 m) than the average for the three close strokes which connected to land (36.9 m). The better estimates of maximum UCL lengths for the eight close strokes average 20.2 m, with slightly shorter average of 18.3 m for the five that connected to water. All the better estimates of UCL maximum lengths are <38 m in this dataset

  1. Video attention deviation estimation using inter-frame visual saliency map analysis

    NASA Astrophysics Data System (ADS)

    Feng, Yunlong; Cheung, Gene; Le Callet, Patrick; Ji, Yusheng

    2012-01-01

    A viewer's visual attention during video playback is the matching of his eye gaze movement to the changing video content over time. If the gaze movement matches the video content (e.g., follow a rolling soccer ball), then the viewer keeps his visual attention. If the gaze location moves from one video object to another, then the viewer shifts his visual attention. A video that causes a viewer to shift his attention often is a "busy" video. Determination of which video content is busy is an important practical problem; a busy video is difficult for encoder to deploy region of interest (ROI)-based bit allocation, and hard for content provider to insert additional overlays like advertisements, making the video even busier. One way to determine the busyness of video content is to conduct eye gaze experiments with a sizable group of test subjects, but this is time-consuming and costineffective. In this paper, we propose an alternative method to determine the busyness of video-formally called video attention deviation (VAD): analyze the spatial visual saliency maps of the video frames across time. We first derive transition probabilities of a Markov model for eye gaze using saliency maps of a number of consecutive frames. We then compute steady state probability of the saccade state in the model-our estimate of VAD. We demonstrate that the computed steady state probability for saccade using saliency map analysis matches that computed using actual gaze traces for a range of videos with different degrees of busyness. Further, our analysis can also be used to segment video into shorter clips of different degrees of busyness by computing the Kullback-Leibler divergence using consecutive motion compensated saliency maps.

  2. The Timescale-dependent Color Variability of Quasars Viewed with /GALEX

    NASA Astrophysics Data System (ADS)

    Zhu, Fei-Fan; Wang, Jun-Xian; Cai, Zhen-Yi; Sun, Yu-Han

    2016-11-01

    In a recent work by Sun et al., the color variation of quasars, namely the bluer-when-brighter trend, was found to be timescale dependent using the SDSS g/r band light curves in Stripe 82. Such timescale dependence, I.e., bluer variation at shorter timescales, supports the thermal fluctuation origin of the UV/optical variation in quasars, and can be modeled well with the inhomogeneous accretion disk model. In this paper, we extend the study to much shorter wavelengths in the rest frame (down to extreme UV) using GALaxy Evolution eXplorer (GALEX) photometric data of quasars collected in two ultraviolet bands (near-UV and far-UV). We develop Monte Carlo simulations to correct for possible biases due to the considerably larger photometric uncertainties in the GALEX light curves (particularly in the far-UV, compared with the SDSS g/r bands), which otherwise could produce artificial results. We securely confirm the previously discovered timescale dependence of the color variability with independent data sets and at shorter wavelengths. We further find that the slope of the correlation between the amplitude of the color variation and timescale appears even steeper than predicted by the inhomogeneous disk model, which assumes that disk fluctuations follow a damped random walk (DRW) process. The much flatter structure function observed in the far-UV compared with that at longer wavelengths implies deviation from the DRW process in the inner disk, where rest-frame extreme UV radiation is produced.

  3. A calendar method of collecting remittance use data in a remittance dependent setting of Nepal1

    PubMed Central

    Bhandari, Prem; Chaudhary, Indra

    2018-01-01

    This methodological paper describes the design and refinement of a calendar method of collecting data on remittance receipt and remittance use and its piloting in a rural remittance dependent setting of Nepal. Much of the previous national surveys collected remittance receipt and remittance use cross-sectional data that used a time frame ranging from 12 – 24 months. These surveys collected remittance receipt data by asking, ‘How much money has he/she sent in the past 12 months or 2 years?’ We believe that the long time frame of one to two years adds burden to respondents for unnecessary calculations and is prone to re-call bias. Moreover, these surveys used vague words such as ‘capital formation’ or ‘daily consumption’ to measure the uses of remittances. Thus, the instrument per se is unreliable posing threats to collecting valid responses. Considering these flaws, in 2013, we designed a calendar with shorter timing cues and simple words for collecting longitudinal data on remittance receipt and remittance use. First, we describe the calendar design process. Next, we provide descriptive results of household responses on the amount of remittance received and the remittance used on various socio-economic and cultural dimensions of household activities. The implications of the insights gained from this study are discussed. PMID:29399417

  4. Rapid motif compliance scoring with match weight sets.

    PubMed

    Venezia, D; O'Hara, P J

    1993-02-01

    Most current implementations of motif matching in biological sequences have sacrificed the generality of weight matrix scoring for shorter runtimes. The program MOTIF incorporates a weight matrix and a rapid, backtracking tree-search algorithm to score motif compliance with greatly enhanced performance while placing no constraints on the motif. In addition, any positions within a motif can be marked as 'inviolate', thereby requiring an exact match. MOTIF allows a choice of regular expression formats and can use both motif and sequence libraries as either targets or queries. Nucleic acid sequences can optionally be translated by MOTIF in any frame(s) and used against peptide motifs.

  5. Comparative Effectiveness of Frame-based, Frameless and Intraoperative MRI Guided Brain Biopsy Techniques

    PubMed Central

    Lu, Yi; Yeung, Cecil; Radmanesh, Alireza; Wiemann, Robert; Black, Peter M.; Golby, Alexandra J.

    2015-01-01

    Objective Intraoperative MRI (IoMRI) guided brain biopsy provides a real time visual feedback of the lesion that is sampled during surgery. The objective of the study is to compare the diagnostic yield and safety profiles of ioMRI needle brain biopsy with two traditional brain biopsy methods: frame-based and frameless stereotactic brain biopsies. Methods A retrospective analysis from 288 consecutive needle brain biopsies in 277 patients undergoing stereotactic brain biopsy with any of the three biopsy methods at Brigham and Women's Hospital from 2000 to 2008 was performed. Variables such as age, sex, history of radiation and previous surgery, pathology results, complications and postoperative stays were analyzed. Results Over the course of eight years, 288 brain biopsies were performed. 253 (87.8%) biopsies yielded positive diagnostic tissue. Young age (<40 years), history of brain radiation or surgery were significant negative predictors for a positive biopsy diagnostic yield. Excluding patients with prior radiation or surgeries, no significant difference in diagnostic yield was detected among the three groups, with frame-based, frameless and ioMRI guided needle biopsies yield 96.9%, 91.8% and 89.9% positive diagnostic yield, respectively. 19 biopsies (6.6%) were complicated by serious adverse events. The ioMRI-guided brain biopsy was associated with less serious adverse events and the shortest postoperative hospital stay. Conclusions Frame-based, frameless stereotactic and ioMRI guided brain needle biopsy have comparable diagnostic yield for patients with no prior treatments (either radiation or surgery). IoMRI guided brain biopsy is associated with fewer serious adverse events and shorter hospital stay. PMID:25088233

  6. On the Use of Parmetric-CAD Systems and Cartesian Methods for Aerodynamic Design

    NASA Technical Reports Server (NTRS)

    Nemec, Marian; Aftosmis, Michael J.; Pulliam, Thomas H.

    2004-01-01

    Automated, high-fidelity tools for aerodynamic design face critical issues in attempting to optimize real-life geometry arid in permitting radical design changes. Success in these areas promises not only significantly shorter design- cycle times, but also superior and unconventional designs. To address these issues, we investigate the use of a parmetric-CAD system in conjunction with an embedded-boundary Cartesian method. Our goal is to combine the modeling capabilities of feature-based CAD with the robustness and flexibility of component-based Cartesian volume-mesh generation for complex geometry problems. We present the development of an automated optimization frame-work with a focus on the deployment of such a CAD-based design approach in a heterogeneous parallel computing environment.

  7. Sex and age-level differences of walking time in preschool children on an obstacle frame

    PubMed Central

    2012-01-01

    Background Stepping over an obstacle is a kind of compound movement that makes walking more difficult, especially for preschool children. This study examines sex and age-level differences in walking time in preschool children on an obstacle frame. Methods The participants included 324 healthy preschool children: four-year-old boys (51) and girls (51), five-year-old boys (50) and girls (60), and six-year-old boys (62) and girls (50). A 5 cm- or 10 cm-high obstacle (depth 11.5 cm, width 23.5 cm) was set at the halfway point of a 200 cm × 10 cm walking course. Results The participants walked to the end of the course and back as fast as possible under three conditions: no obstacle, low obstacle and high obstacle. Walking time showed age-level differences in all conditions, but there were no differences in sex. Age levels were divided into two groups, with one group within the first six months of their birthday, and the second group within the last six months of that year. Walking time for children in the first half of their fourth year was longer than that of the five- and six-year-old children. In addition, for children in the last half of their fourth year, walking time was longer than both sexes in the last half of their fifth and sixth years. The children in the latter half of their fifth year had a longer walking time in the high obstacle condition than those in the last half of their sixth year. In the four-year-old participants, walking time was shorter with no obstacles than with a high obstacle frame. Conclusions In the above data, obstacle course walking time does not show a gender difference, except that the four-year-old participants needed longer than the five- and six-year-old children. Setting the obstacle 10 cm high also produced a different walking time in the five- and six-year-old participants. The high obstacle step test (10 cm) best evaluated the dynamic balance of preschool children. PMID:22738328

  8. Measuring the quality-of-life effects of diagnostic and screening tests.

    PubMed

    Swan, J Shannon; Miksad, Rebecca A

    2009-08-01

    Health-related quality of life (HRQL) is a central concept for understanding the outcomes of medical care. When used in cost-effectiveness analysis, HRQL is typically measured for conditions persisting over long time frames (years), and quality-adjusted life year (QALY) values are generated. Consequently, years are the basic unit of time for cost-effectiveness analysis results: dollars spent per QALY gained. However, shorter term components of health care may also affect HRQL, and there is increased interest in measuring and accounting for these events. In radiology, the short-term HRQL effects of screening and diagnostic testing may affect a test's cost-effectiveness, even though they may only last for days. The unique challenge in radiology HRQL assessment is to realistically tap into the testing and screening experience while remaining consistent with QALY theory. The authors review HRQL assessment and highlight methods developed to specifically address the short-term effects of radiologic screening and testing.

  9. Refinement of the charcoal meal study by reduction of the fasting period.

    PubMed

    Prior, Helen; Ewart, Lorna; Bright, Jonathan; Valentin, Jean-Pierre

    2012-05-01

    The aim of this investigation was to determine whether a shorter fasting period than the one historically employed for the charcoal meal test, could be used when measuring gastric emptying and intestinal transit within the same animal, and to ascertain whether the scientific outcome would be affected by this benefit to animal welfare. Rats and mice were fasted for 0, 3, 6 or 18 hours before the oral administration of vehicle or atropine. One hour later, the animals were orally administered a charcoal meal, then 20 minutes later, they were killed and the stomach and small intestine were removed. Intestinal transit time (the position of the charcoal front as a percentage of the total length of the small intestine) and relative gastric emptying (weight of stomach contents) were measured. Rats and mice fasted for six hours showed results for gastric emptying and intestinal transit which were similar to those obtained in animals fasted for 18 hours. Reducing the fasting period reduced the body weight loss in both species, and mice on shorter fasts could be group-housed, as hunger-induced fighting was lessened. Therefore, a fasting period of six hours was subsequently adopted for charcoal meal studies at our institution. 2011 FRAME.

  10. Communicating likelihoods and probabilities in forecasts of volcanic eruptions

    NASA Astrophysics Data System (ADS)

    Doyle, Emma E. H.; McClure, John; Johnston, David M.; Paton, Douglas

    2014-02-01

    The issuing of forecasts and warnings of natural hazard events, such as volcanic eruptions, earthquake aftershock sequences and extreme weather often involves the use of probabilistic terms, particularly when communicated by scientific advisory groups to key decision-makers, who can differ greatly in relative expertise and function in the decision making process. Recipients may also differ in their perception of relative importance of political and economic influences on interpretation. Consequently, the interpretation of these probabilistic terms can vary greatly due to the framing of the statements, and whether verbal or numerical terms are used. We present a review from the psychology literature on how the framing of information influences communication of these probability terms. It is also unclear as to how people rate their perception of an event's likelihood throughout a time frame when a forecast time window is stated. Previous research has identified that, when presented with a 10-year time window forecast, participants viewed the likelihood of an event occurring ‘today’ as being of less than that in year 10. Here we show that this skew in perception also occurs for short-term time windows (under one week) that are of most relevance for emergency warnings. In addition, unlike the long-time window statements, the use of the phrasing “within the next…” instead of “in the next…” does not mitigate this skew, nor do we observe significant differences between the perceived likelihoods of scientists and non-scientists. This finding suggests that effects occurring due to the shorter time window may be ‘masking’ any differences in perception due to wording or career background observed for long-time window forecasts. These results have implications for scientific advice, warning forecasts, emergency management decision-making, and public information as any skew in perceived event likelihood towards the end of a forecast time window may result in an underestimate of the likelihood of an event occurring ‘today’ leading to potentially inappropriate action choices. We thus present some initial guidelines for communicating such eruption forecasts.

  11. Perceptually specific and perceptually non-specific influences on rereading benefits for spatially transformed text: evidence from eye movements.

    PubMed

    Sheridan, Heather; Reingold, Eyal M

    2012-12-01

    The present study used eye tracking methodology to examine rereading benefits for spatially transformed text. Eye movements were monitored while participants read the same target word twice, in two different low-constraint sentence frames. The congruency of perceptual processing was manipulated by either applying the same type of transformation to the word during the first and second presentations (i.e., the congruent condition), or employing two different types of transformations across the two presentations of the word (i.e., the incongruent condition). Perceptual specificity effects were demonstrated such that fixation times for the second presentation of the target word were shorter for the congruent condition compared to the incongruent condition. Moreover, we demonstrated an additional perceptually non-specific effect such that second reading fixation times were shorter for the incongruent condition relative to a baseline condition that employed a normal typography (i.e., non-transformed) during the first presentation and a transformation during the second presentation. Both of these effects (i.e., perceptually specific and perceptually non-specific) were similar in magnitude for high and low frequency words, and both effects persisted across a 1 week lag between the first and second readings. We discuss the present findings in the context of the distinction between conscious and unconscious memory, and the distinction between perceptually versus conceptually driven processing. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Ultrafast dynamic contrast-enhanced mri of the breast using compressed sensing: breast cancer diagnosis based on separate visualization of breast arteries and veins.

    PubMed

    Onishi, Natsuko; Kataoka, Masako; Kanao, Shotaro; Sagawa, Hajime; Iima, Mami; Nickel, Marcel Dominik; Toi, Masakazu; Togashi, Kaori

    2018-01-01

    To evaluate the feasibility of ultrafast dynamic contrast-enhanced (UF-DCE) magnetic resonance imaging (MRI) with compressed sensing (CS) for the separate identification of breast arteries/veins and perform temporal evaluations of breast arteries and veins with a focus on the association with ipsilateral cancers. Our Institutional Review Board approved this study with retrospective design. Twenty-five female patients who underwent UF-DCE MRI at 3T were included. UF-DCE MRI consisting of 20 continuous frames was acquired using a prototype 3D gradient-echo volumetric interpolated breath-hold sequence including a CS reconstruction: temporal resolution, 3.65 sec/frame; spatial resolution, 0.9 × 1.3 × 2.5 mm. Two readers analyzed 19 maximum intensity projection images reconstructed from subtracted images, separately identified breast arteries/veins and the earliest frame in which they were respectively visualized, and calculated the time interval between arterial and venous visualization (A-V interval) for each breast. In total, 49 breasts including 31 lesions (breast cancer, 16; benign lesion, 15) were identified. In 39 of the 49 breasts (breasts with cancers, 16; breasts with benign lesions, 10; breasts with no lesions, 13), both breast arteries and veins were separately identified. The A-V intervals for breasts with cancers were significantly shorter than those for breasts with benign lesions (P = 0.043) and no lesions (P = 0.007). UF-DCE MRI using CS enables the separate identification of breast arteries/veins. Temporal evaluations calculating the time interval between arterial and venous visualization might be helpful in the differentiation of ipsilateral breast cancers from benign lesions. 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:97-104. © 2017 International Society for Magnetic Resonance in Medicine.

  13. As the world turns: short-term human spatial memory in egocentric and allocentric coordinates.

    PubMed

    Banta Lavenex, Pamela; Lecci, Sandro; Prêtre, Vincent; Brandner, Catherine; Mazza, Christian; Pasquier, Jérôme; Lavenex, Pierre

    2011-05-16

    We aimed to determine whether human subjects' reliance on different sources of spatial information encoded in different frames of reference (i.e., egocentric versus allocentric) affects their performance, decision time and memory capacity in a short-term spatial memory task performed in the real world. Subjects were asked to play the Memory game (a.k.a. the Concentration game) without an opponent, in four different conditions that controlled for the subjects' reliance on egocentric and/or allocentric frames of reference for the elaboration of a spatial representation of the image locations enabling maximal efficiency. We report experimental data from young adult men and women, and describe a mathematical model to estimate human short-term spatial memory capacity. We found that short-term spatial memory capacity was greatest when an egocentric spatial frame of reference enabled subjects to encode and remember the image locations. However, when egocentric information was not reliable, short-term spatial memory capacity was greater and decision time shorter when an allocentric representation of the image locations with respect to distant objects in the surrounding environment was available, as compared to when only a spatial representation encoding the relationships between the individual images, independent of the surrounding environment, was available. Our findings thus further demonstrate that changes in viewpoint produced by the movement of images placed in front of a stationary subject is not equivalent to the movement of the subject around stationary images. We discuss possible limitations of classical neuropsychological and virtual reality experiments of spatial memory, which typically restrict the sensory information normally available to human subjects in the real world. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. A comparison of the mechanical properties of fiberglass cast materials and their clinical relevance.

    PubMed

    Berman, A T; Parks, B G

    1990-01-01

    The mechanical properties of five synthetic fiberglass casting materials were evaluated and compared with the properties of plaster of Paris. Two of the tests were designed to bear clinical relevance and the third to determine intrinsic material properties. The effect of water on strength degradation was also evaluated. It was found that the synthetics as a group are far superior to plaster of Paris in all methods of testing and that, among the synthetics, KCast Tack Free, Deltalite "S", and KCast Improved were the stronger materials. Clinically, the most important results are that the synthetics attain their relatively high strength in a much shorter time frame than does plaster of Paris, and retain 70-90% of their strength after being immersed in water and allowed to dry.

  15. Analysis of Costs and Time Frame for Reducing CO2 Emissions by 70% in the U.S. Auto and Energy Sectors by 2050.

    PubMed

    Supekar, Sarang D; Skerlos, Steven J

    2017-10-03

    Using a least-cost optimization framework, it is shown that unless emissions reductions beyond those already in place begin at the latest by 2025 (±2 years) for the U.S. automotive sector, and by 2026 (-3 years) for the U.S. electric sector, 2050 targets to achieve necessary within-sector preventative CO 2 emissions reductions of 70% or more relative to 2010 will be infeasible. The analysis finds no evidence to justify delaying climate action in the name of reducing technological costs. Even without considering social and environmental damage costs, delaying aggressive climate action does not reduce CO 2 abatement costs even under the most optimistic trajectories for improvements in fuel efficiencies, demand, and technology costs in the U.S. auto and electric sectors. In fact, the abatement cost for both sectors is found to increase sharply with every year of delay beyond 2020. When further considering reasonable limits to technology turnover, retirements, and new capacity additions, these costs would be higher, and the feasible time frame for initiating successful climate action on the 70% by 2050 target would be shorter, perhaps having passed already. The analysis also reveals that optimistic business-as-usual scenarios in the U.S. will, conservatively, release 79-108 billion metric tons of CO 2 . This could represent up to 13% of humanity's remaining carbon budget through 2050.

  16. The effect of character contextual diversity on eye movements in Chinese sentence reading.

    PubMed

    Chen, Qingrong; Zhao, Guoxia; Huang, Xin; Yang, Yiming; Tanenhaus, Michael K

    2017-12-01

    Chen, Huang, et al. (Psychonomic Bulletin & Review, 2017) found that when reading two-character Chinese words embedded in sentence contexts, contextual diversity (CD), a measure of the proportion of texts in which a word appears, affected fixation times to words. When CD is controlled, however, frequency did not affect reading times. Two experiments used the same experimental designs to examine whether there are frequency effects of the first character of two-character words when CD is controlled. In Experiment 1, yoked triples of characters from a control group, a group matched for character CD that is lower in frequency, and a group matched in frequency with the control group, but higher in character CD, were rotated through the same sentence frame. In Experiment 2 each character from a larger set was embedded in a separate sentence frame, allowing for a larger difference in log frequency compared to Experiment 1 (0.8 and 0.4, respectively). In both experiments, early and later eye movement measures were significantly shorter for characters with higher CD than for characters with lower CD, with no effects of character frequency. These results place constraints on models of visual word recognition and suggest ways in which Chinese can be used to tease apart the nature of context effects in word recognition and language processing in general.

  17. Implementation of enhanced recovery programme after pancreatoduodenectomy: a single-centre UK pilot study.

    PubMed

    Abu Hilal, Mohammed; Di Fabio, Francesco; Badran, Abdallah; Alsaati, Hani; Clarke, Hannah; Fecher, Imogen; Armstrong, Thomas H; Johnson, Colin D; Pearce, Neil W

    2013-01-01

    Data on enhanced recovery programmes after pancreatoduodenectomy (ERP-PD) is limited. The aim of this pilot study was to evaluate the feasibility, safety and clinical outcomes of ERP-PD when implemented at a high-volume UK university referral centre. This was an observational single-surgeon case-control study (before-and-after pathway). A total of 20 consecutive patients were prospectively enrolled for the ERP-PD and compared with 24 consecutive patients previously treated during an equal time frame. Patients in the ERP-PD group had a significant shorter time to remove naso-gastric tube (median of 5 vs. 7 days, p = 0.0001), start liquid diet (median of 2 vs. 5 days, p < 0.0001), start solid food (median of 4 vs. 9 days, p < 0.0001), pass stools (median of 6 vs. 7 days, p = 0.002), and had shorter length of stay (median of 8.5 days vs. 13 days, p = 0.015) compared to the pre-pathway group. Postoperative complications were overall less frequent but not significantly different in the ERP-PD group (p = 0.077). No difference in mortality and readmission rates was found. Our findings support the feasibility and safety of ERP-PD. Improved patients' outcomes, significant bed day savings and increase National Health Service productivity are anticipated with implementation of ERP-PD on a larger scale. Copyright © 2012 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  18. Coronal Fine Structure in Dynamic Events Observed by Hi-C

    NASA Technical Reports Server (NTRS)

    Winebarger, Amy; Schuler, Timothy

    2013-01-01

    The High-Resolution Coronal Imager (Hi-C) flew aboard a NASA sounding rocket on 2012 July 11 and captured roughly 345 s of high spatial and temporal resolution images of the solar corona in a narrowband 193 Angstrom channel. We have analyzed the fluctuations in intensity of Active Region 11520. We selected events based on a lifetime greater than 11 s (two Hi-C frames) and intensities greater than a threshold determined from the photon and readout noise. We compare the Hi-C events with those determined from AIA. We find that HI-C detects shorter and smaller events than AIA. We also find that the intensity increase in the Hi-C events is approx. 3 times greater than the intensity increase in the AIA events we conclude the events are related to linear sub-structure that is unresolved by AIA

  19. Predicting drug hydrolysis based on moisture uptake in various packaging designs.

    PubMed

    Naversnik, Klemen; Bohanec, Simona

    2008-12-18

    An attempt was made to predict the stability of a moisture sensitive drug product based on the knowledge of the dependence of the degradation rate on tablet moisture. The moisture increase inside a HDPE bottle with the drug formulation was simulated with the sorption-desorption moisture transfer model, which, in turn, allowed an accurate prediction of the drug degradation kinetics. The stability prediction, obtained by computer simulation, was made in a considerably shorter time frame and required little resources compared to a conventional stability study. The prediction was finally upgraded to a stochastic Monte Carlo simulation, which allowed quantitative incorporation of uncertainty, stemming from various sources. The resulting distribution of the outcome of interest (amount of degradation product at expiry) is a comprehensive way of communicating the result along with its uncertainty, superior to single-value results or confidence intervals.

  20. Discovery of an X-ray Violently Variable Broad Absorption Line Quasar

    NASA Technical Reports Server (NTRS)

    Ghosh, Kajal K.; Gutierrez, Carlos M.; Punsly, Brian; Chevallier, Loic; Goncalves, Anabela C.

    2006-01-01

    In this letter, we report on a quasar that is violently variable in the X-rays, XVV. It is also a broad absorption line quasar (BALQSO) that exhibits both high ionization and low ionization UV absorption lines (LoBALQSO). It is very luminous in the X-rays (approximately 10(exp 46) ergs s(sup -l) over the entire X-ray band). Surprisingly, this does not over ionize the LoBAL outflow. The X-rays vary by a factor of two within minutes in the quasar rest frame, which is shorter than 1/30 of the light travel time across a scale length equal to the black hole radius. We concluded that the X-rays are produced in a relativistic jet beamed toward earth in which variations in the Doppler enhancement produce the XVV behavior.

  1. Three-dimensional particle tracking velocimetry algorithm based on tetrahedron vote

    NASA Astrophysics Data System (ADS)

    Cui, Yutong; Zhang, Yang; Jia, Pan; Wang, Yuan; Huang, Jingcong; Cui, Junlei; Lai, Wing T.

    2018-02-01

    A particle tracking velocimetry algorithm based on tetrahedron vote, which is named TV-PTV, is proposed to overcome the limited selection problem of effective algorithms for 3D flow visualisation. In this new cluster-matching algorithm, tetrahedrons produced by the Delaunay tessellation are used as the basic units for inter-frame matching, which results in a simple algorithmic structure of only two independent preset parameters. Test results obtained using the synthetic test image data from the Visualisation Society of Japan show that TV-PTV presents accuracy comparable to that of the classical algorithm based on new relaxation method (NRX). Compared with NRX, TV-PTV possesses a smaller number of loops in programming and thus a shorter computing time, especially for large particle displacements and high particle concentration. TV-PTV is confirmed practically effective using an actual 3D wake flow.

  2. Fractional Langevin Equation Model for Characterization of Anomalous Brownian Motion from NMR Signals

    NASA Astrophysics Data System (ADS)

    Lisý, Vladimír; Tóthová, Jana

    2018-02-01

    Nuclear magnetic resonance is often used to study random motion of spins in different systems. In the long-time limit the current mathematical description of the experiments allows proper interpretation of measurements of normal and anomalous diffusion. The shorter-time dynamics is however correctly considered only in a few works that do not go beyond the standard Langevin theory of the Brownian motion (BM). In the present work, the attenuation function S (t) for an ensemble of spins in a magnetic-field gradient, expressed in a form applicable for any kind of stationary stochastic dynamics of spins with or without a memory, is calculated in the frame of the model of fractional BM. The solution of the model for particles trapped in a harmonic potential is obtained in a simple way and used for the calculation of S (t). In the limit of free particles coupled to a fractal heat bath, the results compare favorably with experiments acquired in human neuronal tissues.

  3. Impacts of GNSS position offsets on global frame stability

    NASA Astrophysics Data System (ADS)

    Griffiths, Jake; Ray, Jim

    2015-04-01

    Positional offsets appear in Global Navigation Satellite System (GNSS) time series for a variety of reasons. Antenna or radome changes are the most common cause for these discontinuities. Many others are from earthquakes, receiver changes, and different anthropogenic modifications at or near the stations. Some jumps appear for unknown or undocumented reasons. Accurate determination of station velocities, and therefore geophysical parameters and terrestrial reference frames, requires that positional offsets be correctly found and compensated. Williams (2003) found that undetected offsets introduce a random walk error component in individual station time series. The topic of detecting positional offsets has received considerable attention in recent years (e.g., Detection of Offsets in GPS Experiment; DOGEx), and most research groups using GNSS have adopted a mix of manual and automated methods for finding them. The removal of a positional offset from a time series is usually handled by estimating the average station position on both sides of the discontinuity. Except for large earthquake events, the velocity is usually assumed constant and continuous across the positional jump. This approach is sufficient in the absence of time-correlated errors. However, GNSS time series contain periodic and power-law (flicker) errors. In this paper, we evaluate the impact to individual station results and the overall stability of the global reference frame from adding increasing numbers of positional discontinuities. We use the International GNSS Service (IGS) weekly SINEX files, and iteratively insert positional offset parameters. Each iteration includes a restacking of the modified SINEX files using the CATREF software from Institut National de l'Information Géographique et Forestière (IGN). Comparisons of successive stacked solutions are used to assess the impacts on the time series of x-pole and y-pole offsets, along with changes in regularized position and secular velocity for stations with more than 2.5 years of data. Our preliminary results indicate that the change in polar motion scatter is logarithmic with increasing numbers of discontinuities. The best-fit natural logarithm to the changes in scatter for x-pole has R2 = 0.58; the fit for the y-pole series has R2 = 0.99. From these empirical functions, we find that polar motion scatter increases from zero when the total rate of discontinuities exceeds 0.2 (x-pole) and 1.3 (y-pole) per station, on average (the IGS has 0.65 per station). Thus, the presence of position offsets in GNSS station time series is likely already a contributor to IGS polar motion inaccuracy and global frame instability. Impacts to station position and velocity estimates depend on noise features found in that station's positional time series. For instance, larger changes in velocity occur for stations with shorter and noisier data spans. This is because an added discontinuity parameter for an individual station time series can induce changes in average position on both sides of the break. We will expand on these results, and consider remaining questions about the role of velocity discontinuities and the effects caused by non-core reference frame stations.

  4. 28 CFR 570.21 - Time-frames.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Time-frames. 570.21 Section 570.21... PROGRAMS Pre-Release Community Confinement § 570.21 Time-frames. (a) Community confinement. Inmates may be... inmate's term of imprisonment or six months. (c) Exceeding time-frames. These time-frames may be exceeded...

  5. 28 CFR 570.21 - Time-frames.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Time-frames. 570.21 Section 570.21... PROGRAMS Pre-Release Community Confinement § 570.21 Time-frames. (a) Community confinement. Inmates may be... inmate's term of imprisonment or six months. (c) Exceeding time-frames. These time-frames may be exceeded...

  6. 28 CFR 570.21 - Time-frames.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Time-frames. 570.21 Section 570.21... PROGRAMS Pre-Release Community Confinement § 570.21 Time-frames. (a) Community confinement. Inmates may be... inmate's term of imprisonment or six months. (c) Exceeding time-frames. These time-frames may be exceeded...

  7. 28 CFR 570.21 - Time-frames.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Time-frames. 570.21 Section 570.21... PROGRAMS Pre-Release Community Confinement § 570.21 Time-frames. (a) Community confinement. Inmates may be... inmate's term of imprisonment or six months. (c) Exceeding time-frames. These time-frames may be exceeded...

  8. 28 CFR 570.21 - Time-frames.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Time-frames. 570.21 Section 570.21... PROGRAMS Pre-Release Community Confinement § 570.21 Time-frames. (a) Community confinement. Inmates may be... inmate's term of imprisonment or six months. (c) Exceeding time-frames. These time-frames may be exceeded...

  9. 12 CFR 516.190 - Will a meeting affect application processing time frames?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... time frames? 516.190 Section 516.190 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE... processing time frames? If OTS decides to conduct a meeting, it may suspend applicable application processing time frames, including the time frames for deeming an application complete and the applicable approval...

  10. Resource and energy management of synfuels production with hydrogen and oxygen requirements from electrolysis

    NASA Astrophysics Data System (ADS)

    Shannon, R. H.; Richardson, R. D.

    The Resource and Energy Management System (REM), which uses electrolytic H2 and O2 to produce synthetic crude and light oils from heavy hydrocarbons is described. The heavy hydrocarbon feedstocks include heavy oils, tar sand bitumens, heavy residual oils, oil shale kerogens, liquefied coal, and pyrolytically-extracted coal liquids. The system includes mini-upgraders, which can be implemented in modular form, to pump electrolytically-derived H2 into heavy oils to upgrade their energy content. Projected costs for the production of synthetic light oils using U.S. coal reserves with the REM process after liquefaction are $30-35/bbl, with the H2 costs being a controlling factor. The modular systems could be built in a much shorter time frame than much larger projects, and would be instrumental in establishing the electrolytic H2 production infrastructure needed for eventual full conversion to an H2-based economy.

  11. A new approach to accelerated drug-excipient compatibility testing.

    PubMed

    Sims, Jonathan L; Carreira, Judith A; Carrier, Daniel J; Crabtree, Simon R; Easton, Lynne; Hancock, Stephen A; Simcox, Carol E

    2003-01-01

    The purpose of this study was to develop a method of qualitatively predicting the most likely degradants in a formulation or probing specific drug-excipient interactions in a significantly shorter time frame than the typical 1 month storage testing. In the example studied, accelerated storage testing of a solid dosage form at 50 degrees C, the drug substance SB-243213-A degraded via the formation of two oxidative impurities. These impurities reached a level of 1% PAR after 3 months. Various stressing methods were examined to try to recreate this degradation and in doing so provide a practical and reliable method capable of predicting drug-excipient interactions. The technique developed was able to mimic the 1-month's accelerated degradation in just 1 hr. The method was suitable for automated analysis, capable of multisample stressing, and ideal for use in drug-excipient compatibility screening.

  12. 42 CFR 405.942 - Time frame for filing a request for a redetermination.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Time frame for filing a request for a...) Redeterminations § 405.942 Time frame for filing a request for a redetermination. (a) Time frame for filing a.... (b) Extending the time frame for filing a request. General rule. If the 120 calendar day period in...

  13. How does a soap film burst during generation?

    NASA Astrophysics Data System (ADS)

    Rio, Emmanuelle; Saulnier, Laurie; Restagno, Frederic; Langevin, Dominique

    2011-11-01

    Foams are dispersions of bubbles in a liquid matrix in the presence of stabilizing surfactants. Even if foams are ubiquitous, the ability of a solution to create a certain foam quantity is still not fully understood. As a first step, we choose to work on a simplified system and studied the stability of a soap film during its generation. We have built an experiment, in which we determine simultaneously the velocity of a frame pulled out of a soapy solution and the entire shape of the liquid film. We found that the film is made of two parts: the bottom part is of uniform and stationary thickness, well described by the classical Frankel's law; in the top part, the film drains until a black film appears near the frame upper boundary frame, and then bursts. In this study, we characterize both part of the films and show that the Frankel law breaks down at high capillary number due to surfactants confinement. We also explain why films pulled at high velocity have a shorter lifetime than those pulled at low velocity. L. Saulnier is funded by CNES.

  14. Situations of car-to-pedestrian contact.

    PubMed

    Matsui, Yasuhiro; Hitosugi, Masahito; Takahashi, Kunio; Doi, Tsutomu

    2013-01-01

    To reduce the severity of injuries and the number of pedestrian deaths in traffic accidents, active safety devices providing pedestrian detection are considered effective countermeasures. The features of car-to-pedestrian collisions need to be known in detail to develop such safety devices. Because information on real-world accidents is limited, this study investigated near-miss situations captured by drive recorders installed in passenger cars. We showed similarities of the contact situation between near-miss incidents and real-world fatal pedestrian accidents in Japan. We analyzed the near-miss incident data via video capturing pedestrians crossing the road in front of forward-moving cars. Using a video frame captured by a drive recorder, the time to collision (TTC) was calculated from the car velocity and the distance between the car and pedestrian at the moment that the pedestrian initially appeared. The average TTC in the cases where pedestrians were not using a pedestrian crossing was shorter than that in the cases where pedestrians were using a pedestrian crossing. The average TTC in the cases where pedestrians emerged from behind obstructions was shorter than that in the cases where drivers had unobstructed views of the pedestrians. We propose that the specifications of the safety device for pedestrian detection and automatic braking should reflect the severe approach situation for a pedestrian and car including the TTC observed for near-miss incidents.

  15. Innovations in Clinical Trial Design in the Era of Molecular Profiling.

    PubMed

    Wulfkuhle, Julia D; Spira, Alexander; Edmiston, Kirsten H; Petricoin, Emanuel F

    2017-01-01

    Historically, cancer has been studied, and therapeutic agents have been evaluated based on organ site, clinical staging, and histology. The science of molecular profiling has expanded our knowledge of cancer at the cellular and molecular level such that numerous subtypes are being described based on biomarker expression and genetic mutations rather than traditional classifications of the disease. Drug development has experienced a concomitant revolution in response to this knowledge with many new targeted therapeutic agents becoming available, and this has necessitated an evolution in clinical trial design. The traditional, large phase II and phase III adjuvant trial models need to be replaced with smaller, shorter, and more focused trials. These trials need to be more efficient and adaptive in order to quickly assess the efficacy of new agents and develop new companion diagnostics. We are now seeing a substantial shift from the traditional multiphase trial model to an increase in phase II adjuvant and neoadjuvant trials in earlier-stage disease incorporating surrogate endpoints for long-term survival to assess efficacy of therapeutic agents in shorter time frames. New trial designs have emerged with capabilities to assess more efficiently multiple disease types, multiple molecular subtypes, and multiple agents simultaneously, and regulatory agencies have responded by outlining new pathways for accelerated drug approval that can help bring effective targeted therapeutic agents to the clinic more quickly for patients in need.

  16. The effect of life expectancy on aggression and generativity: a life history perspective.

    PubMed

    Dunkel, Curtis S; Mathes, Eugene; Papini, Dennis R

    2010-09-23

    Following a model that is inclusive of both dispositional and situational influences on life-history behaviors and attitudes, the effect of life expectancies on aggression and generativity was examined. Consistent with the hypotheses it was found that shorter life expectancies led to an increase in the desire to aggress and a decrease in the desire to engage in generative behaviors. The results are discussed in terms of how life history theory can be used to frame research on person-situation interactions.

  17. 10 CFR 710.35 - Time frames.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Time frames. 710.35 Section 710.35 Energy DEPARTMENT OF... Matter or Special Nuclear Material Miscellaneous § 710.35 Time frames. Statements of time established for processing aspects of a case under this subpart are the agency's desired time frames in implementing the...

  18. 10 CFR 710.35 - Time frames.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Time frames. 710.35 Section 710.35 Energy DEPARTMENT OF... Matter or Special Nuclear Material Miscellaneous § 710.35 Time frames. Statements of time established for processing aspects of a case under this subpart are the agency's desired time frames in implementing the...

  19. 10 CFR 710.35 - Time frames.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Time frames. 710.35 Section 710.35 Energy DEPARTMENT OF... Matter or Special Nuclear Material Miscellaneous § 710.35 Time frames. Statements of time established for processing aspects of a case under this subpart are the agency's desired time frames in implementing the...

  20. 10 CFR 710.35 - Time frames.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Time frames. 710.35 Section 710.35 Energy DEPARTMENT OF... Matter or Special Nuclear Material Miscellaneous § 710.35 Time frames. Statements of time established for processing aspects of a case under this subpart are the agency's desired time frames in implementing the...

  1. Early dynamic 18F-FDG PET to detect hyperperfusion in hepatocellular carcinoma liver lesions.

    PubMed

    Schierz, Jan-Henning; Opfermann, Thomas; Steenbeck, Jörg; Lopatta, Eric; Settmacher, Utz; Stallmach, Andreas; Marlowe, Robert J; Freesmeyer, Martin

    2013-06-01

    In addition to angiographic data on vascularity and vascular access, demonstration of hepatocellular carcinoma (HCC) liver nodule hypervascularization is a prerequisite for certain intrahepatic antitumor therapies. Early dynamic (ED) (18)F-FDG PET/CT could serve this purpose when the current standard method, contrast-enhanced (CE) CT, or other CE morphologic imaging modalities are unsuitable. A recent study showed ED (18)F-FDG PET/CT efficacy in this setting but applied a larger-than-standard (18)F-FDG activity and an elaborate protocol likely to hinder routine use. We developed a simplified protocol using standard activities and easily generated visual and descriptive or quantitative endpoints. This pilot study assessed the ability of these endpoints to detect HCC hyperperfusion and, thereby, evaluated the suitability in of the protocol everyday practice. Twenty-seven patients with 34 HCCs (diameter ≥ 1.5 cm) with hypervascularization on 3-phase CE CT underwent liver ED (18)F-FDG PET for 240 s, starting with (18)F-FDG (250-MBq bolus injection). Four frames at 15-s intervals, followed by 3 frames at 60-s intervals were reconstructed. Endpoints included focal tracer accumulation in the first 4 frames (60 s), subsequent focal washout, and visual and quantitative differences between tumor and liver regions of interest in maximum and mean ED standardized uptake value (ED SUVmax and ED SUVmean, respectively) 240-s time-activity curves. All 34 lesions were identified by early focal (18)F-FDG accumulation and faster time-to-peak ED SUVmax or ED SUVmean than in nontumor tissue. Tumor peak ED SUVmax and ED SUVmean exceeded liver levels in 85% and 53%, respectively, of lesions. Nadir tumor signal showed no consistent pattern relative to nontumor signal. HCC had a significantly shorter time to peak and significantly faster rate to peak for both ED SUVmax and ED SUVmean curves and a significantly higher peak ED SUVmax but not peak ED SUVmean than the liver. This pilot study provided proof of principle that our simplified ED (18)F-FDG PET/CT protocol includes endpoints that effectively detect HCC hypervascularization; this finding suggests that the protocol can be used routinely.

  2. A 65k pixel, 150k frames-per-second camera with global gating and micro-lenses suitable for fluorescence lifetime imaging

    NASA Astrophysics Data System (ADS)

    Burri, Samuel; Powolny, François; Bruschini, Claudio E.; Michalet, Xavier; Regazzoni, Francesco; Charbon, Edoardo

    2014-05-01

    This paper presents our work on a 65k pixel single-photon avalanche diode (SPAD) based imaging sensor realized in a 0.35μm standard CMOS process. At a resolution of 512 by 128 pixels the sensor is read out in 6.4μs to deliver over 150k monochrome frames per second. The individual pixel has a size of 24μm2 and contains the SPAD with a 12T quenching and gating circuitry along with a memory element. The gating signals are distributed across the chip through a balanced tree to minimize the signal skew between the pixels. The array of pixels is row-addressable and data is sent out of the chip on 128 lines in parallel at a frequency of 80MHz. The system is controlled by an FPGA which generates the gating and readout signals and can be used for arbitrary real-time computation on the frames from the sensor. The communication protocol between the camera and a conventional PC is USB2. The active area of the chip is 5% and can be significantly improved with the application of a micro-lens array. A micro-lens array, for use with collimated light, has been designed and its performance is reviewed in the paper. Among other high-speed phenomena the gating circuitry capable of generating illumination periods shorter than 5ns can be used for Fluorescence Lifetime Imaging (FLIM). In order to measure the lifetime of fluorophores excited by a picosecond laser, the sensor's illumination period is synchronized with the excitation laser pulses. A histogram of the photon arrival times relative to the excitation is then constructed by counting the photons arriving during the sensitive time for several positions of the illumination window. The histogram for each pixel is transferred afterwards to a computer where software routines extract the lifetime at each location with an accuracy better than 100ps. We show results for fluorescence lifetime measurements using different fluorophores with lifetimes ranging from 150ps to 5ns.

  3. A Blue Spectral Shift of the Hemoglobin Soret Band Correlates with the Age (Time Since Deposition) of Dried Bloodstains

    PubMed Central

    Hanson, Erin K.; Ballantyne, Jack

    2010-01-01

    The ability to determine the time since deposition of a bloodstain found at a crime scene could prove invaluable to law enforcement investigators, defining the time frame in which the individual depositing the evidence was present. Although various methods of accomplishing this have been proposed, none has gained widespread use due to poor time resolution and weak age correlation. We have developed a method for the estimation of the time since deposition (TSD) of dried bloodstains using UV-VIS spectrophotometric analysis of hemoglobin (Hb) that is based upon its characteristic oxidation chemistry. A detailed study of the Hb Soret band (λmax = 412 nm) in aged bloodstains revealed a blue shift (shift to shorter wavelength) as the age of the stain increases. The extent of this shift permits, for the first time, a distinction to be made between bloodstains that were deposited minutes, hours, days and weeks prior to recovery and analysis. The extent of the blue shift was found to be a function of ambient relative humidity and temperature. The method is extremely sensitive, requiring as little as a 1 µl dried bloodstain for analysis. We demonstrate that it might be possible to perform TSD measurements at the crime scene using a portable low-sample-volume spectrophotometer. PMID:20877468

  4. The effects of the framing of time on delay discounting.

    PubMed

    DeHart, William Brady; Odum, Amy L

    2015-01-01

    We examined the effects of the framing of time on delay discounting. Delay discounting is the process by which delayed outcomes are devalued as a function of time. Time in a titrating delay discounting task is often framed in calendar units (e.g., as 1 week, 1 month, etc.). When time is framed as a specific date, delayed outcomes are discounted less compared to the calendar format. Other forms of framing time; however, have not been explored. All participants completed a titrating calendar unit delay-discounting task for money. Participants were also assigned to one of two delay discounting tasks: time as dates (e.g., June 1st, 2015) or time in units of days (e.g., 5000 days), using the same delay distribution as the calendar delay-discounting task. Time framed as dates resulted in less discounting compared to the calendar method, whereas time framed as days resulted in greater discounting compared to the calendar method. The hyperboloid model fit best compared to the hyperbola and exponential models. How time is framed may alter how participants attend to the delays as well as how the delayed outcome is valued. Altering how time is framed may serve to improve adherence to goals with delayed outcomes. © Society for the Experimental Analysis of Behavior.

  5. Thinking Fast Increases Framing Effects in Risky Decision Making.

    PubMed

    Guo, Lisa; Trueblood, Jennifer S; Diederich, Adele

    2017-04-01

    Every day, people face snap decisions when time is a limiting factor. In addition, the way a problem is presented can influence people's choices, which creates what are known as framing effects. In this research, we explored how time pressure interacts with framing effects in risky decision making. Specifically, does time pressure strengthen or weaken framing effects? On one hand, research has suggested that framing effects evolve through the deliberation process, growing larger with time. On the other hand, dual-process theory attributes framing effects to an intuitive, emotional system that responds automatically to stimuli. In our experiments, participants made decisions about gambles framed in terms of either gains or losses, and time pressure was manipulated across blocks. Results showed increased framing effects under time pressure in both hypothetical and incentivized choices, which supports the dual-process hypothesis that these effects arise from a fast, intuitive system.

  6. High-frame-rate infrared and visible cameras for test range instrumentation

    NASA Astrophysics Data System (ADS)

    Ambrose, Joseph G.; King, B.; Tower, John R.; Hughes, Gary W.; Levine, Peter A.; Villani, Thomas S.; Esposito, Benjamin J.; Davis, Timothy J.; O'Mara, K.; Sjursen, W.; McCaffrey, Nathaniel J.; Pantuso, Francis P.

    1995-09-01

    Field deployable, high frame rate camera systems have been developed to support the test and evaluation activities at the White Sands Missile Range. The infrared cameras employ a 640 by 480 format PtSi focal plane array (FPA). The visible cameras employ a 1024 by 1024 format backside illuminated CCD. The monolithic, MOS architecture of the PtSi FPA supports commandable frame rate, frame size, and integration time. The infrared cameras provide 3 - 5 micron thermal imaging in selectable modes from 30 Hz frame rate, 640 by 480 frame size, 33 ms integration time to 300 Hz frame rate, 133 by 142 frame size, 1 ms integration time. The infrared cameras employ a 500 mm, f/1.7 lens. Video outputs are 12-bit digital video and RS170 analog video with histogram-based contrast enhancement. The 1024 by 1024 format CCD has a 32-port, split-frame transfer architecture. The visible cameras exploit this architecture to provide selectable modes from 30 Hz frame rate, 1024 by 1024 frame size, 32 ms integration time to 300 Hz frame rate, 1024 by 1024 frame size (with 2:1 vertical binning), 0.5 ms integration time. The visible cameras employ a 500 mm, f/4 lens, with integration time controlled by an electro-optical shutter. Video outputs are RS170 analog video (512 by 480 pixels), and 12-bit digital video.

  7. Minimally-Invasive, Image-Guided Cochlear Implantation Surgery: First report of clinical implementation

    PubMed Central

    Labadie, Robert F; Balachandran, Ramya; Noble, Jack H; Blachon, Grégoire S; Mitchell, Jason E; Reda, Fitsum A; Dawant, Benoit M; Fitzpatrick, J Michael

    2015-01-01

    OBJECTIVE Minimally-invasive image-guided approach to cochlear implantation (CI) involves drilling a narrow, linear tunnel to the cochlea. Reported herein is the first clinical implementation of this approach. STUDY DESIGN Prospective, cohort study. METHODS On preoperative CT, a safe linear trajectory through the facial recess targeting the scala tympani was planned. Intraoperatively, fiducial markers were bone-implanted, a second CT was acquired, and the trajectory was transferred from preoperative to intraoperative CT. A customized microstereotactic frame was rapidly designed and constructed to constrain a surgical drill along the desired trajectory. Following sterilization, the frame was employed to drill the tunnel to the middle ear. After lifting a tympanomeatal flap and performing a cochleostomy, the electrode array was threaded through the drilled tunnel and into the cochlea. RESULTS Eight of nine patients were successfully implanted using the proposed approach with six insertions completely within scala tympani. Traditional mastoidectomy was performed on one patient following difficulty threading the electrode array via the narrow tunnel. Other difficulties encountered included use of the back-up implant when an electrode was dislodged during threading via the tunnel, tip fold-over, and facial nerve paresis (House-Brackmann II/VII at 12 months) secondary to heat during drilling. Average time of intervention was 182±36 minutes. CONCLUSION Minimally-invasive, image-guided CI is clinically achievable. Further clinical study is necessary to address technological difficulties during drilling and insertion and to assess potential benefits including decreased time of intervention, standardization of surgical intervention, and decreased tissue dissection potentially leading to shorter recovery and earlier implant activation. PMID:24272427

  8. 42 CFR 457.1160 - Program specific review process: Time frames.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Program specific review process: Time frames. 457... process: Time frames. (a) Eligibility or enrollment matter. A State must complete the review of a matter described in § 457.1130(a) within a reasonable amount of time. In setting time frames, the State must...

  9. Reintroduction of Lake Sturgeon (Acipenser fulvescens) into the St. Regis River, NY: Post-release assessment of habitat use and growth

    USGS Publications Warehouse

    Dittman, Dawn E.; Chalupnicki, Marc A.; Johnson, James H.; Snyder, James

    2015-01-01

    One of the depleted endemic fish species of the Great Lakes, Acipenser fulvescens (Lake Sturgeon), has been the target of extensive conservation efforts. One strategy is reintroduction into historically productive waters. The St. Regis River, NY, represents one such adaptive-management effort, with shared management between New York and the St. Regis Mohawk Tribe. Between 1998 and 2004, a total of 4977 young-of-year Lake Sturgeon were released. Adaptive management requires intermediate progress metrics. During 2004 and 2005, we measured growth, habitat use, and survivorship metrics of the released fish. We captured a total of 95 individuals of all stocked ages. Year-class minimal-survival rates ranged from 0.19–2.1%. The size-at-age and length/biomass relationships were comparable to those reported for juveniles in other Great Lakes waters. These intermediate assessment metrics can provide feedback to resource managers who make restoration-program decisions on a much shorter time-scale than the time-frame in which the ultimate goal of a self-sustaining population can be attained.

  10. Characteristics of the three-half-turn-antenna-driven RF discharge in the Uragan-3M torsatron

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grigor’eva, L. I.; Chechkin, V. V., E-mail: chechkin@ipp.kharkov.ua; Moiseenko, V. E.

    In the ℓ = 3 Uragan-3M torsatron hydrogen plasma is produced by RF fields in the Alfvén range of frequencies (ω ≤ ω{sub ci}). The initial (target) plasma with the line-averaged density of units 10{sup 12} cm{sup −3} is produced by a frame antenna with a broad spectrum of generated parallel wavenumbers. After this, to heat the plasma and bring its density to ∼10{sup 13} cm{sup –3}, another, shorter wavelength three-half-turn antenna with large transverse currents is used. The behavior of the density, electron temperature, and loss of the plasma supported by the three-half-turn antenna is studied depending on themore » RF power fed to the antenna and initial values of the density and electron temperature supplied by the frame antenna.« less

  11. Comparison of method using phase-sensitive motion estimator with speckle tracking method and application to measurement of arterial wall motion

    NASA Astrophysics Data System (ADS)

    Miyajo, Akira; Hasegawa, Hideyuki

    2018-07-01

    At present, the speckle tracking method is widely used as a two- or three-dimensional (2D or 3D) motion estimator for the measurement of cardiovascular dynamics. However, this method requires high-level interpolation of a function, which evaluates the similarity between ultrasonic echo signals in two frames, to estimate a subsample small displacement in high-frame-rate ultrasound, which results in a high computational cost. To overcome this problem, a 2D motion estimator using the 2D Fourier transform, which does not require any interpolation process, was proposed by our group. In this study, we compared the accuracies of the speckle tracking method and our method using a 2D motion estimator, and applied the proposed method to the measurement of motion of a human carotid arterial wall. The bias error and standard deviation in the lateral velocity estimates obtained by the proposed method were 0.048 and 0.282 mm/s, respectively, which were significantly better than those (‑0.366 and 1.169 mm/s) obtained by the speckle tracking method. The calculation time of the proposed phase-sensitive method was 97% shorter than the speckle tracking method. Furthermore, the in vivo experimental results showed that a characteristic change in velocity around the carotid bifurcation could be detected by the proposed method.

  12. First-line intra-arterial versus intravenous chemotherapy in unilateral sporadic group D retinoblastoma: evidence of better visual outcomes, ocular survival and shorter time to success with intra-arterial delivery from retrospective review of 20 years of treatment.

    PubMed

    Munier, Francis L; Mosimann, Pascal; Puccinelli, Francesco; Gaillard, Marie-Claire; Stathopoulos, Christina; Houghton, Susan; Bergin, Ciara; Beck-Popovic, Maja

    2017-08-01

    The introduction of intra-arterial chemotherapy (IAC) as salvage treatment has improved the prognosis for eye conservation in group D retinoblastoma. The aim of this study was to compare the outcomes of consecutive patients with advanced unilateral disease treated with either first-line intravenous chemotherapy (IVC) or first-line IAC. This is a retrospective mono-centric comparative review of consecutive patients. Sporadic unilateral retinoblastoma group D cases treated conservatively at Jules-Gonin Eye Hospital and CHUV between 1997 and 2014. From January 1997 to August 2008, IVC, combined with focal treatments, was the primary treatment approach. From September 2008 to October 2014, IAC replaced IVC as first-line therapy. 48 patients met the inclusion criteria, receiving only either IAC or IVC as primary treatment modality. Outcomes of 23 patients treated by IVC were compared with those of 25 treated by IAC; mean follow-up was 105.3 months (range 29.2-218.6) and 41.7 months (range 19.6-89.5), respectively. Treatment duration was significantly shorter in the IAC group (p<0.001). Ten eyes in the IVC group underwent enucleation. Recordable visual acuity of the salvaged eyes was significantly better in the IAC group (0.9 vs 1.4 logarithm of the minimum angle of resolution, p<0.01). No extraocular disease, metastases or long-term systemic complications were observed in either group. The difference in the time frame between treatment groups had an impact on the availability of intravitreal chemotherapy treatment. Despite this, the results reported here imply that eyes treated with first-line IAC will have shorter treatment period, better ocular survival and visual acuity than first-line IVC. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. 42 CFR 405.950 - Time frame for making a redetermination.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... decision-making time frame begins on the date the contractor receives the late-filed request for... filed, the contractor's 60 calendar day decision-making time frame is extended for up to 14 calendar... 42 Public Health 2 2010-10-01 2010-10-01 false Time frame for making a redetermination. 405.950...

  14. Nonchronological video synopsis and indexing.

    PubMed

    Pritch, Yael; Rav-Acha, Alex; Peleg, Shmuel

    2008-11-01

    The amount of captured video is growing with the increased numbers of video cameras, especially the increase of millions of surveillance cameras that operate 24 hours a day. Since video browsing and retrieval is time consuming, most captured video is never watched or examined. Video synopsis is an effective tool for browsing and indexing of such a video. It provides a short video representation, while preserving the essential activities of the original video. The activity in the video is condensed into a shorter period by simultaneously showing multiple activities, even when they originally occurred at different times. The synopsis video is also an index into the original video by pointing to the original time of each activity. Video Synopsis can be applied to create a synopsis of an endless video streams, as generated by webcams and by surveillance cameras. It can address queries like "Show in one minute the synopsis of this camera broadcast during the past day''. This process includes two major phases: (i) An online conversion of the endless video stream into a database of objects and activities (rather than frames). (ii) A response phase, generating the video synopsis as a response to the user's query.

  15. Electronic clinical predictive thermometer using logarithm for temperature prediction

    NASA Technical Reports Server (NTRS)

    Cambridge, Vivien J. (Inventor); Koger, Thomas L. (Inventor); Nail, William L. (Inventor); Diaz, Patrick (Inventor)

    1998-01-01

    A thermometer that rapidly predicts body temperature based on the temperature signals received from a temperature sensing probe when it comes into contact with the body. The logarithms of the differences between the temperature signals in a selected time frame are determined. A line is fit through the logarithms and the slope of the line is used as a system time constant in predicting the final temperature of the body. The time constant in conjunction with predetermined additional constants are used to compute the predicted temperature. Data quality in the time frame is monitored and if unacceptable, a different time frame of temperature signals is selected for use in prediction. The processor switches to a monitor mode if data quality over a limited number of time frames is unacceptable. Determining the start time on which the measurement time frame for prediction is based is performed by summing the second derivatives of temperature signals over time frames. When the sum of second derivatives in a particular time frame exceeds a threshold, the start time is established.

  16. Do foreign exchange and equity markets co-move in Latin American region? Detrended cross-correlation approach

    NASA Astrophysics Data System (ADS)

    Bashir, Usman; Yu, Yugang; Hussain, Muntazir; Zebende, Gilney F.

    2016-11-01

    This paper investigates the dynamics of the relationship between foreign exchange markets and stock markets through time varying co-movements. In this sense, we analyzed the time series monthly of Latin American countries for the period from 1991 to 2015. Furthermore, we apply Granger causality to verify the direction of causality between foreign exchange and stock market and detrended cross-correlation approach (ρDCCA) for any co-movements at different time scales. Our empirical results suggest a positive cross correlation between exchange rate and stock price for all Latin American countries. The findings reveal two clear patterns of correlation. First, Brazil and Argentina have positive correlation in both short and long time frames. Second, the remaining countries are negatively correlated in shorter time scale, gradually moving to positive. This paper contributes to the field in three ways. First, we verified the co-movements of exchange rate and stock prices that were rarely discussed in previous empirical studies. Second, ρDCCA coefficient is a robust and powerful methodology to measure the cross correlation when dealing with non stationarity of time series. Third, most of the studies employed one or two time scales using co-integration and vector autoregressive approaches. Not much is known about the co-movements at varying time scales between foreign exchange and stock markets. ρDCCA coefficient facilitates the understanding of its explanatory depth.

  17. The Evolution of Quasar C IV and Si IV Broad Absorption Lines over Multi-year Timescales

    NASA Astrophysics Data System (ADS)

    Gibson, Robert R.; Brandt, W. N.; Gallagher, S. C.; Hewett, Paul C.; Schneider, Donald P.

    2010-04-01

    We investigate the variability of C IV λ1549 broad absorption line (BAL) troughs over rest-frame timescales of up to ≈7 yr in 14 quasars at redshifts z >~ 2.1. For nine sources at sufficiently high redshift, we also compare the C IV and Si IV λ1400 absorption variation. We compare shorter and longer term variability using spectra from up to four different epochs per source and find complex patterns of variation in the sample overall. The scatter in the change of absorption equivalent width (EW), ΔEW, increases with the time between observations. BALs do not, in general, strengthen or weaken monotonically, and variation observed over shorter (lsimmonths) timescales is not predictive of multi-year variation. We find no evidence for asymmetry in the distribution of ΔEW that would indicate that BALs form and decay on different timescales, and we constrain the typical BAL lifetime to be gsim30 yr. The BAL absorption for one source, LBQS 0022+0150, has weakened and may now be classified as a mini-BAL. Another source, 1235+1453, shows evidence of variable, blue continuum emission that is relatively unabsorbed by the BAL outflow. C IV and Si IV BAL shape changes are related in at least some sources. Given their high velocities, BAL outflows apparently traverse large spatial regions and may interact with parsec-scale structures such as an obscuring torus. Assuming BAL outflows are launched from a rotating accretion disk, notable azimuthal symmetry is required in the outflow to explain the relatively small changes observed in velocity structure over times up to 7 yr.

  18. Determining the locations of the various CIRC recording format information blocks (user data blocks, C2 and C1 words and EFM frames) on a recorded compact disc

    NASA Technical Reports Server (NTRS)

    Howe, Dennis G.

    1993-01-01

    Just prior to its being EFM modulated (i.e., converted to eight-to-fourteen channel data by the EFM encoder) and written to a Compact Disc (CD), information that passes through the CIRC Block Encoder is grouped into 33-byte blocks referred to as EFM frames. Twenty four of the bytes that make up a given EFM frame are user data that was input into the CIRC encoder at various (different) times, 4 of the bytes of this same EFM frame were created by the C2 ECC encoder (each at a different time), and another 4 were created by the C1 ECC encoder (again, each at a different time). The one remaining byte of the given EFM frame, which is known as the EFM frame C&D (for Control & Display) byte, carries information that identifies which portion of the current disc program track the given EFM frame belongs to and also specifies the location of the given EFM frame on the disc (in terms of a time stamp that has a resolution of l/75th second, or 98 EFM frames). (Note: since the program track and time information is stored as a 98-byte word, a logical group consisting of 98 consecutive EFM frames must be read, and their respective C&D bytes must be catenated and decoded, before the program track identification and time position information that pertains to the entire block of 98 EFM frames can be obtained.) The C&D byte is put at the start (0th byte) of an EFM frame in real time; its placement completes the construction of the EFM frame - it is assigned just before the EFM frame enters the EFM encoder. Four distinct blocks of data are referred to: 24-byte User Input Data Blocks; 28-byte C2 words; 32-byte C1 words; and 33-byte EFM frames.

  19. Characteristic properties of the frame-antenna-produced RF discharge evolution in the Uragan-3M torsatron

    NASA Astrophysics Data System (ADS)

    Chechkin, V. V.; Grigor'eva, L. I.; Pavlichenko, R. O.; Kulaga, A. Ye.; Zamanov, N. V.; Moiseenko, V. E.; Burchenko, P. Ya.; Lozin, A. V.; Tsybenko, S. A.; Tarasov, I. K.; Pankratov, I. M.; Grekov, D. L.; Beletskii, A. A.; Kasilov, A. A.; Voitsenya, V. S.; Pashnev, V. K.; Konovalov, V. G.; Shapoval, A. N.; Mironov, Yu. K.; Romanov, V. S.

    2014-08-01

    In the ℓ = 3 Uragan-3M torsatron, hydrogen plasma is produced and heated by RF fields in the Alfvén range of frequencies (ω ≲ ω ci ). To this end, a frame antenna with a broad spectrum of generated parallel wavenumbers is used. The RF discharge evolution is studied experimentally at different values of the RF power fed to the antenna (the anode voltage of the oscillator and the antenna current) and the initial pressure of the fueling gas. It is shown that, depending on the antenna current and hydrogen pressure, the discharge can operate in two regimes differing in the plasma density, temperature, and particle loss. The change in the discharge regime with increasing anode voltage is steplike in character. The particular values of the anode voltage and pressure at which the change occurs are affected by RF preionization or breakdown stabilization by a microwave discharge. The obtained results will be used in future experiments to choose the optimal regimes of the frame-antenna-produced RF discharge as a target for the production and heating of a denser plasma by another, shorter wavelength three-half-turn antenna.

  20. 25 CFR 900.135 - May the time frames for action set out in this subpart be reduced?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false May the time frames for action set out in this subpart be... EDUCATION ASSISTANCE ACT Construction § 900.135 May the time frames for action set out in this subpart be reduced? Yes. The time frames in this subpart are intended to be maximum times and may be reduced based on...

  1. The metabolic cost of changing walking speeds is significant, implies lower optimal speeds for shorter distances, and increases daily energy estimates.

    PubMed

    Seethapathi, Nidhi; Srinivasan, Manoj

    2015-09-01

    Humans do not generally walk at constant speed, except perhaps on a treadmill. Normal walking involves starting, stopping and changing speeds, in addition to roughly steady locomotion. Here, we measure the metabolic energy cost of walking when changing speed. Subjects (healthy adults) walked with oscillating speeds on a constant-speed treadmill, alternating between walking slower and faster than the treadmill belt, moving back and forth in the laboratory frame. The metabolic rate for oscillating-speed walking was significantly higher than that for constant-speed walking (6-20% cost increase for ±0.13-0.27 m s(-1) speed fluctuations). The metabolic rate increase was correlated with two models: a model based on kinetic energy fluctuations and an inverted pendulum walking model, optimized for oscillating-speed constraints. The cost of changing speeds may have behavioural implications: we predicted that the energy-optimal walking speed is lower for shorter distances. We measured preferred human walking speeds for different walking distances and found people preferred lower walking speeds for shorter distances as predicted. Further, analysing published daily walking-bout distributions, we estimate that the cost of changing speeds is 4-8% of daily walking energy budget. © 2015 The Author(s).

  2. The metabolic cost of changing walking speeds is significant, implies lower optimal speeds for shorter distances, and increases daily energy estimates

    PubMed Central

    Seethapathi, Nidhi; Srinivasan, Manoj

    2015-01-01

    Humans do not generally walk at constant speed, except perhaps on a treadmill. Normal walking involves starting, stopping and changing speeds, in addition to roughly steady locomotion. Here, we measure the metabolic energy cost of walking when changing speed. Subjects (healthy adults) walked with oscillating speeds on a constant-speed treadmill, alternating between walking slower and faster than the treadmill belt, moving back and forth in the laboratory frame. The metabolic rate for oscillating-speed walking was significantly higher than that for constant-speed walking (6–20% cost increase for ±0.13–0.27 m s−1 speed fluctuations). The metabolic rate increase was correlated with two models: a model based on kinetic energy fluctuations and an inverted pendulum walking model, optimized for oscillating-speed constraints. The cost of changing speeds may have behavioural implications: we predicted that the energy-optimal walking speed is lower for shorter distances. We measured preferred human walking speeds for different walking distances and found people preferred lower walking speeds for shorter distances as predicted. Further, analysing published daily walking-bout distributions, we estimate that the cost of changing speeds is 4–8% of daily walking energy budget. PMID:26382072

  3. Systematic Analysis of Long Non-Coding RNAs and mRNAs in the Ovaries of Duroc Pigs During Different Follicular Stages Using RNA Sequencing.

    PubMed

    Liu, Yi; Li, Mengxun; Bo, Xinwen; Li, Tao; Ma, Lipeng; Zhai, Tenjiao; Huang, Tao

    2018-06-11

    The dynamic process involving the selection and maturation of follicles is regulated and controlled by a highly synchronized and exquisitely timed cascade of gene expression. Studies have shown that long non-coding RNA (lncRNA) is essential for the normal maintenance of animal reproductive function and has an important regulatory function in ovarian development and hormone secretion. In this study, a total of 2076 lncRNAs (1362 known lncRNAs and 714 new lncRNAs) and 25,491 mRNAs were identified in libraries constructed from Duroc ovaries on days 0, 2 and 4 of follicle development. lncRNAs were shorter, had fewer exons, exhibited a shorter ORF (Open Reading Frame) length and lower expression levels, and were less conserved than mRNAs. Furthermore, 1694 transcripts (140 lncRNAs and 1554 mRNAs) were found to be differentially expressed in pairwise comparisons. A total of 6945 co-localized mRNAs were detected in cis in 2076 lncRNAs. The most enriched GO (Gene Ontology) terms were related to developmental processes. KEGG (Kyoto Encyclopedia of Genes and Genomes) pathway analysis revealed that the differentially expressed lncRNAs targeted mRNAs, and the differentially expressed mRNAs were related to the TGF-β signaling pathway, the PI3K-Akt signaling pathway, the Retinol metabolic pathway and the Wnt signaling pathway. This study deepened our understanding of the genetic basis and molecular mechanisms of follicular development in pigs.

  4. Online Planning Algorithm

    NASA Technical Reports Server (NTRS)

    Rabideau, Gregg R.; Chien, Steve A.

    2010-01-01

    AVA v2 software selects goals for execution from a set of goals that oversubscribe shared resources. The term goal refers to a science or engineering request to execute a possibly complex command sequence, such as image targets or ground-station downlinks. Developed as an extension to the Virtual Machine Language (VML) execution system, the software enables onboard and remote goal triggering through the use of an embedded, dynamic goal set that can oversubscribe resources. From the set of conflicting goals, a subset must be chosen that maximizes a given quality metric, which in this case is strict priority selection. A goal can never be pre-empted by a lower priority goal, and high-level goals can be added, removed, or updated at any time, and the "best" goals will be selected for execution. The software addresses the issue of re-planning that must be performed in a short time frame by the embedded system where computational resources are constrained. In particular, the algorithm addresses problems with well-defined goal requests without temporal flexibility that oversubscribes available resources. By using a fast, incremental algorithm, goal selection can be postponed in a "just-in-time" fashion allowing requests to be changed or added at the last minute. Thereby enabling shorter response times and greater autonomy for the system under control.

  5. Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics

    NASA Technical Reports Server (NTRS)

    Nguyen, Quang-Viet; Fischer, David G.; Kojima, Jun

    2011-01-01

    Accurate experimental measurement of spatially and temporally resolved variations in chemical composition (species concentrations) and temperature in turbulent flames is vital for characterizing the complex phenomena occurring in most practical combustion systems. These diagnostic measurements are called multiscalar because they are capable of acquiring multiple scalar quantities simultaneously. Multiscalar diagnostics also play a critical role in the area of computational code validation. In order to improve the design of combustion devices, computational codes for modeling turbulent combustion are often used to speed up and optimize the development process. The experimental validation of these codes is a critical step in accepting their predictions for engine performance in the absence of cost-prohibitive testing. One of the most critical aspects of setting up a time-resolved stimulated Raman scattering (SRS) diagnostic system is the temporal optical gating scheme. A short optical gate is necessary in order for weak SRS signals to be detected with a good signal- to-noise ratio (SNR) in the presence of strong background optical emissions. This time-synchronized optical gating is a classical problem even to other spectroscopic techniques such as laser-induced fluorescence (LIF) or laser-induced breakdown spectroscopy (LIBS). Traditionally, experimenters have had basically two options for gating: (1) an electronic means of gating using an image intensifier before the charge-coupled-device (CCD), or (2) a mechanical optical shutter (a rotary chopper/mechanical shutter combination). A new diagnostic technology has been developed at the NASA Glenn Research Center that utilizes a frame-transfer CCD sensor, in conjunction with a pulsed laser and multiplex optical fiber collection, to realize time-resolved Raman spectroscopy of turbulent flames that is free from optical background noise (interference). The technology permits not only shorter temporal optical gating (down to <1 s, in principle), but also higher optical throughput, thus resulting in a substantial increase in measurement SNR.

  6. Modeling the formation of N-nitrosodimethylamine (NDMA) from the reaction of natural organic matter (NOM) with monochloramine.

    PubMed

    Chen, Zhuo; Valentine, Richard L

    2006-12-01

    This paper presents mechanistic studies on the formation of NDMA, a newly identified chloramination disinfection byproduct, from reactions of monochloramine with natural organic matter. A kinetic model was developed to validate proposed reactions and to predict NDMA formation in chloraminated water during the time frame of 1-5 days. This involved incorporating NDMA formation reactions into an established comprehensive model describing the oxidation of humic-type natural organic matter by monochloramine. A rate-limiting step involving the oxidation of NOM is theorized to control the rate of NDMA formation which is assumed to be proportional to the rate of NOM oxidized by monochloramine. The applicability of the model to describe NDMA formation in the presence of three NOM sources over a wide range in water quality (i.e., pH, DOC, and ammonia concentrations) was evaluated. Results show that with accurate measurement of monochloramine demand for a specific supply, NDMA formation could be modeled over an extended range of experimental conditions by considering a single NOM source-specific value of thetaNDMA, a stoichiometric coefficient relating the amount of NDMA produced to the amount of NOM oxidized, and several kinetic parameters describing NOM oxidation. Furthermore, the oxidation of NOM is the rate-limiting step governing NDMA formation. This suggests that NDMA formation over a 1-5 day time frame may be estimated from information on the chloramine or free chlorine demand of the NOM and the source-specific linear relationship between this demand and NDMA formation. Although the proposed model has not yet been validated for shorter time periods that may better characterize the residence time in some distribution systems, the improved understanding of the important reactions governing NDMA formation and the resulting model should benefit the water treatment industry as a tool in developing strategies that minimize NDMA formation.

  7. Gain versus loss framing in adherence-promoting communication targeting patients with chronic diseases: the moderating effect of individual time perspective.

    PubMed

    Zhao, Xiaoquan; Villagran, Melinda M; Kreps, Gary L; McHorney, Colleen

    2012-01-01

    This study investigated the joint effect of message framing and time perspective in adherence-promoting communication targeting patients with chronic diseases. Based on previous framing and time perspective research, it was hypothesized that the gain frame would show an advantage over the loss frame among future-oriented patients; for present-oriented patients, it was hypothesized that the framing effect would be relatively indistinct. In total, 1,108 currently nonadherent patients with chronic disease participated in an experiment where they were randomly assigned to either gain- or loss-framed messages addressing key beliefs underlying their nonadherence or a no-message control condition. Intention and attitude regarding future adherence as well as message perceptions were measured after message presentation. Results of this study generally supported the hypotheses. Message topics-whether the messages addressed patients' perceived need for medications or concerns about side effects-did not moderate the effect of framing or the interaction between framing and time perspective. Theoretical and practical implications are discussed.

  8. Endovascular aortic sealing with Nellix reduces intraoperative radiation dose when compared to endovascular aortic repair.

    PubMed

    Ockert, Stefan; Heinrich, Mirjam; Kaufmann, Thomas; Syburra, Thomas; Lopez, Ruben; Seelos, Robert

    2018-04-01

    To analyze radiation exposure during endovascular aortic sealing (EVAS) in comparison with standard endovascular aortic repair (EVAR) in clinical practice. From December 2013 to October 2016 (35 months), 60 patients were analyzed for intraoperative radiation exposure during EVAR: 30 consecutive patients (mean age, 73.10 years; 28 male) received EVAS (Nellix Endologix); within the same time frame, 30 patients were treated with standard EVAR (mean age, 71.87 years; 30 male). An indirect dose analysis was performed for both groups of patients, including effective dose and cumulative air kerma. Furthermore, fluoroscopy time (FT), dose area product, and time of procedure were included in the study. The effective dose was significantly reduced in the EVAS group (3.72 mSv) compared with the group treated with standard EVAR (6.8 mSv; P ≤ .001). The cumulative air kerma was also lowered in EVAS (67.65 mGy vs 139 mGy in EVAR; P ≤ .001). FT for the entire group was 13 minutes and was shorter (P < .001) for EVAS (9 minutes) in comparison with EVAR (19 minutes). The dose area product for the entire cohort was 16.95 Gy.cm 2 and was lower during EVAS (12.4 Gy.cm 2 ) than during EVAR (22.6 Gy.cm 2 ; P < .001). The median operating time for the entire group was 123.5 minutes and was significantly shorter (P < .01) for EVAS (119 minutes vs EVAR at 132 minutes). The FT shows a significant correlation with the patient's weight (P = .022), body mass index (P = .004), and time of procedure (P = .005). EVAS is associated with a relevant decrease in indirect measured radiation dose and time of procedure compared with standard EVAR. A relevant reduction in dose during EVAS is highly likely to result in lower exposure to radiation for physicians and staff. Such a result would be highly advantageous and calls for further analysis. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  9. 45 CFR 286.160 - What are the applicable time frames and procedures for submitting a Tribal Family Assistance Plan?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false What are the applicable time frames and procedures... and Processing § 286.160 What are the applicable time frames and procedures for submitting a Tribal... Secretary according to the following time frames: Implementation date: Letter of intent due to ACF and the...

  10. A transform from absorption to Raman excitation profile. A time-dependent approach

    NASA Astrophysics Data System (ADS)

    Lee, Soo-Y.; Yeo, Robert C. K.

    1994-04-01

    An alternative time-frame approach, which is canonically conjugate to the energy-frame approach, for implementing the transform relations for calculating Raman excitation profiles directly from the optical absorption spectrum is presented. Practical and efficient fast Fourier transformation in the time frame replaces the widely used Chan and Page algorithm for evaluating the Hilbert transform in the energy frame. The time-frame approach is applied to: (a) a two-mode model which illustrates the missing mode effect in both absorption and Raman excitation profiles, (b) carotene, in which both the absorption spectrum and the Raman excitation profile show vibrational structure and (c) hexamethylbenzene: TCNE electron donor—acceptor complex where the same spectra are structureless and the Raman excitation profile for the 168 cm -1 mode poses a problem for the energy-frame approach. A similar time-frame approach can be used for the inverse transform from the Raman excitation profile to the optical absorption spectrum.

  11. DNA polymerase ι: The long and the short of it!

    PubMed

    Frank, Ekaterina G; McLenigan, Mary P; McDonald, John P; Huston, Donald; Mead, Samantha; Woodgate, Roger

    2017-10-01

    The cDNA encoding human DNA polymerase ι (POLI) was cloned in 1999. At that time, it was believed that the POLI gene encoded a protein of 715 amino acids. Advances in DNA sequencing technologies led to the realization that there is an upstream, in-frame initiation codon that would encode a DNA polymerase ι (polι) protein of 740 amino acids. The extra 25 amino acid region is rich in acidic residues (11/25) and is reasonably conserved in eukaryotes ranging from fish to humans. As a consequence, the curated Reference Sequence (RefSeq) database identified polι as a 740 amino acid protein. However, the existence of the 740 amino acid polι has never been shown experimentally. Using highly specific antibodies to the 25 N-terminal amino acids of polι, we were unable to detect the longer 740 amino acid (ι-long) isoform in western blots. However, trace amounts of the ι-long isoform were detected after enrichment by immunoprecipitation. One might argue that the longer isoform may have a distinct biological function, if it exhibits significant differences in its enzymatic properties from the shorter, well-characterized 715 amino acid polι. We therefore purified and characterized recombinant full-length (740 amino acid) polι-long and compared it to full-length (715 amino acid) polι-short in vitro. The metal ion requirements for optimal catalytic activity differ slightly between ι-long and ι-short, but under optimal conditions, both isoforms exhibit indistinguishable enzymatic properties in vitro. We also report that like ι-short, the ι-long isoform can be monoubiquitinated and polyubiuquitinated in vivo, as well as form damage induced foci in vivo. We conclude that the predominant isoform of DNA polι in human cells is the shorter 715 amino acid protein and that if, or when, expressed, the longer 740 amino acid isoform has identical properties to the considerably more abundant shorter isoform. Published by Elsevier B.V.

  12. Noninertial coordinate time: A new concept affecting time standards, time transfers, and clock synchronization

    NASA Technical Reports Server (NTRS)

    Deines, Steven D.

    1992-01-01

    Relativity compensations must be made in precise and accurate measurements whenever an observer is accelerated. Although many believe the Earth-centered frame is sufficiently inertial, accelerations of the Earth, as evidenced by the tides, prove that it is technically a noninertial system for even an Earth-based observer. Using the constant speed of light, a set of fixed remote clocks in an inertial frame can be synchronized to a fixed master clock transmitting its time in that frame. The time on the remote clock defines the coordinate time at that coordinate position. However, the synchronization procedure for an accelerated frame is affected, because the distance between the master and remote clocks is altered due to the acceleration of the remote clock toward or away from the master clock during the transmission interval. An exact metric that converts observations from noninertial frames to inertial frames was recently derived. Using this metric with other physical relationships, a new concept of noninertial coordinate time is defined. This noninertial coordinate time includes all relativity compensations. This new issue raises several timekeeping issues, such as proper time standards, time transfer process, and clock synchronization, all in a noninertial frame such as Earth.

  13. Gaining perspective: the effects of message frame on viewer attention to and recall of osteoporosis prevention print advertisements.

    PubMed

    O'Malley, Deborah A; Latimer-Cheung, Amy E

    2013-11-01

    This study examined how framed messages affect viewer attention to and cognitive processing of osteoporosis prevention print ads. Attention was measured with eye tracking technology. Cognitive processing was assessed through masked recall. A total of 60 college-aged women viewed 12 gain-framed, 12 loss-framed, and 12 neutral-framed ads. Number of fixations, dwell time, and recall of gain-framed osteoporosis prevention ads were higher than loss-framed or neutral-framed ads, p < .01. Message recall was positively correlated with the number of fixations and dwell time for the gain-framed and neutral-framed messages, p < .01. These findings provide preliminary insight into potential mechanisms underlying message framing effects.

  14. Appropriateness of selecting different averaging times for modelling chronic and acute exposure to environmental odours

    NASA Astrophysics Data System (ADS)

    Drew, G. H.; Smith, R.; Gerard, V.; Burge, C.; Lowe, M.; Kinnersley, R.; Sneath, R.; Longhurst, P. J.

    Odour emissions are episodic, characterised by periods of high emission rates, interspersed with periods of low emissions. It is frequently the short term, high concentration peaks that result in annoyance in the surrounding population. Dispersion modelling is accepted as a useful tool for odour impact assessment, and two approaches can be adopted. The first approach of modelling the hourly average concentration can underestimate total odour concentration peaks, resulting in annoyance and complaints. The second modelling approach involves the use of short averaging times. This study assesses the appropriateness of using different averaging times to model the dispersion of odour from a landfill site. We also examine perception of odour in the community in conjunction with the modelled odour dispersal, by using community monitors to record incidents of odour. The results show that with the shorter averaging times, the modelled pattern of dispersal reflects the pattern of observed odour incidents recorded in the community monitoring database, with the modelled odour dispersing further in a north easterly direction. Therefore, the current regulatory method of dispersion modelling, using hourly averaging times, is less successful at capturing peak concentrations, and does not capture the pattern of odour emission as indicated by the community monitoring database. The use of short averaging times is therefore of greater value in predicting the likely nuisance impact of an odour source and in framing appropriate regulatory controls.

  15. Experimental anti-GBM nephritis as an analytical tool for studying spontaneous lupus nephritis.

    PubMed

    Du, Yong; Fu, Yuyang; Mohan, Chandra

    2008-01-01

    Systemic lupus erythematosus (SLE) is an autoimmune disease that results in immune-mediated damage to multiple organs. Among these, kidney involvement is the most common and fatal. Spontaneous lupus nephritis (SLN) in mouse models has provided valuable insights into the underlying mechanisms of human lupus nephritis. However, SLN in mouse models takes 6-12 months to manifest; hence there is clearly the need for a mouse model that can be used to unveil the pathogenic processes that lead to immune nephritis over a shorter time frame. In this article more than 25 different molecules are reviewed that have been studied both in the anti-glomerular basement membrane (anti-GBM) model and in SLN and it was found that these molecules influence both diseases in a parallel fashion, suggesting that the two disease settings share common molecular mechanisms. Based on these observations, the authors believe the experimental anti-GBM disease model might be one of the best tools currently available for uncovering the downstream molecular mechanisms leading to SLN.

  16. SS 433: Total Coverage of 162-Day Precession Phase in Four Years

    NASA Technical Reports Server (NTRS)

    Band, David L.

    1997-01-01

    The observations prior to AO-4 covered a number of precession phases, leaving a gap at phase 0.8. In addition, ASCA and previous observations of SS 433 did not observe the spectrum above approx. 10 keV, and consequently the continuum underlying the spectral lines was poorly constrained. Therefore RXTE observations were scheduled for April 1997 to extend the observed spectrum to higher energies; these observations were planned to sample the X-ray lightcurve during the 13.08 day binary period, concentrating on the eclipse of the compact object which emits the jets. We proposed and were awarded ASCA observations simultaneous with the RXTE observations; the purpose of the ASCA observations was to provide greater spectral resolution at the low end of the spectrum observed by RXTE, and to complete the phase coverage of SS 433. As a result of scheduling difficulties early in the mission the RXTE observations were confined to a much shorter time range than originally planned, April 18-91 1997. Optical observations of SS 433 were performed at a number of observatories. The ASCA observations occurred from April 18 13:10 (UT) to April 21 13:20 (UT) for a total effective exposure of 120 ks. The continuum X-ray light curve shows that the ASCA observations started shortly before the ingress into the X-ray partial eclipse, and ended approximately at the time of the egress. Light curves were also obtained for the prominent Fe emission lines in the blue-shifted frame (approaching jet), red-shifted frame (receding jet), and the stationary frame (fluorescent line from the ambient matter). Through the eclipse mapping technique using the light curves, the parameters of the jet emission model were constrained, showing that the kinetic power in the jet exceeds 104? erg s-l. If the energy source is gravitational accretion, as is commonly believed, the derived l;inetic power implies extremely supercritical accretion even for a black; hole with 10M. These results will be described more fully in a major presentation of all the ASCA observations of SS 433.

  17. Southern Auroras Over Saturn

    NASA Image and Video Library

    2017-07-28

    Cassini gazed toward high southern latitudes near Saturn's south pole to observe ghostly curtains of dancing light -- Saturn's southern auroras, or southern lights. These natural light displays at the planet's poles are created by charged particles raining down into the upper atmosphere, making gases there glow. The dark area at the top of this scene is Saturn's night side. The auroras rotate from left to right, curving around the planet as Saturn rotates over about 70 minutes, compressed here into a movie sequence of about five seconds. Background stars are seen sliding behind the planet. Cassini was moving around Saturn during the observation, keeping its gaze fixed on a particular spot on the planet, which causes a shift in the distant background over the course of the observation. Some of the stars seem to make a slight turn to the right just before disappearing. This effect is due to refraction -- the starlight gets bent as it passes through the atmosphere, which acts as a lens. Random bright specks and streaks appearing from frame to frame are due to charged particles and cosmic rays hitting the camera detector. The aim of this observation was to observe seasonal changes in the brightness of Saturn's auroras, and to compare with the simultaneous observations made by Cassini's infrared and ultraviolet imaging spectrometers. The original images in this movie sequence have a size of 256x256 pixels; both the original size and a version enlarged to 500x500 pixels are available here. The small image size is the result of a setting on the camera that allows for shorter exposure times than full-size (1024x1024 pixel) images. This enabled Cassini to take more frames in a short time and still capture enough photons from the auroras for them to be visible. The images were taken in visible light using the Cassini spacecraft narrow-angle camera on July 20, 2017, at a distance of about 620,000 miles (1 million kilometers) from Saturn. The views look toward 74 degrees south latitude on Saturn. Image scale is about 0.9 mile (1.4 kilometers) per pixel on Saturn. An animation is available at https://photojournal.jpl.nasa.gov/catalog/PIA21623

  18. Advanced optical network architecture for integrated digital avionics

    NASA Astrophysics Data System (ADS)

    Morgan, D. Reed

    1996-12-01

    For the first time in the history of avionics, the network designer now has a choice in selecting the media that interconnects the sources and sinks of digital data on aircraft. Electrical designs are already giving way to photonics in application areas where the data rate times distance product is large or where special design requirements such as low weight or EMI considerations are critical. Future digital avionic architectures will increasingly favor the use of photonic interconnects as network data rates of one gigabit/second and higher are needed to support real-time operation of high-speed integrated digital processing. As the cost of optical network building blocks is reduced and as temperature-rugged laser sources are matured, metal interconnects will be forced to retreat to applications spanning shorter and shorter distances. Although the trend is already underway, the widespread use of digital optics will first occur at the system level, where gigabit/second, real-time interconnects between sensors, processors, mass memories and displays separated by a least of few meters will be required. The application of photonic interconnects for inter-printed wiring board signalling across the backplane will eventually find application for gigabit/second applications since signal degradation over copper traces occurs before one gigabit/second and 0.5 meters are reached. For the foreseeable future however, metal interconnects will continue to be used to interconnect devices on printed wiring boards since 5 gigabit/second signals can be sent over metal up to around 15 centimeters. Current-day applications of optical interconnects at the system level are described and a projection of how advanced optical interconnect technology will be driven by the use of high speed integrated digital processing on future aircraft is presented. The recommended advanced network for application in the 2010 time frame is a fiber-based system with a signalling speed of around 2-3 gigabits per second. This switch-based unified network will interconnect sensors, displays, mass memory and controls and displays to computer modules within the processing complex. The characteristics of required building blocks needed for the future are described. These building blocks include the fiber, an optical switch, a laser-based transceiver, blind-mate connectors and an optical backplane.

  19. Stapled haemorrhoidopexy for the treatment of haemorrhoids: a systematic review.

    PubMed

    Burch, J; Epstein, D; Sari, A Baba-Akbari; Weatherly, H; Jayne, D; Fox, D; Woolacott, N

    2009-03-01

    This systematic review aimed to evaluate the short- and long-term safety, efficacy and costs of stapled haemorrhoidopexy (SH) compared with conventional haemorrhoidectomy. We searched 26 electronic databases and websites for studies in any language up to July 2006. Inclusion criteria were predefined, and each stage of the review process was conducted in duplicate. Twenty-seven randomized controlled trials were included (n = 2279). All had some methodological flaws. Postoperatively, 19 trials (95%) reported less pain, 17 (89%) reported a shorter operating time, 14 (88%) a shorter hospital stay, and 14 (93%) a shorter convalescence time following SH. However, prolapse was significantly more common after SH (OR 3.38; 95% CI: 1.00, 11.47). In the longer term, prolapse was significantly more common after SH (OR 4.34; 95% CI: 1.67, 11.28) as was reintervention for prolapse (OR 6.78; 95% CI: 2.00, 23.00). There were no differences in the rate or type of complications. Conventional haemorrhoidectomy and SH had similar costs during the initial admission. Compared with conventional haemorrhoidectomy, SH resulted in less postoperative pain, shorter operating time, a shorter hospital stay, and a shorter convalescence, but a higher rate of prolapse and reintervention for prolapse.

  20. Solid-state framing camera with multiple time frames

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, K. L.; Stewart, R. E.; Steele, P. T.

    2013-10-07

    A high speed solid-state framing camera has been developed which can operate over a wide range of photon energies. This camera measures the two-dimensional spatial profile of the flux incident on a cadmium selenide semiconductor at multiple times. This multi-frame camera has been tested at 3.1 eV and 4.5 keV. The framing camera currently records two frames with a temporal separation between the frames of 5 ps but this separation can be varied between hundreds of femtoseconds up to nanoseconds and the number of frames can be increased by angularly multiplexing the probe beam onto the cadmium selenide semiconductor.

  1. 39 CFR 775.12 - Time frames for environmental impact statement actions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Time frames for environmental impact statement... NATIONAL ENVIRONMENTAL POLICY ACT PROCEDURES § 775.12 Time frames for environmental impact statement... environmental impact statements received in that office during the preceding week. The minimum time periods for...

  2. Self-motion perception compresses time experienced in return travel.

    PubMed

    Seno, Takeharu; Ito, Hiroyuki; Shoji, Sunaga

    2011-01-01

    It is often anecdotally reported that time experienced in return travel (back to the start point) seems shorter than time spent in outward travel (travel to a new destination). Here, we report the first experimental results showing that return travel time is experienced as shorter than the actual time. This discrepancy is induced by the existence of self-motion perception.

  3. Older adults display concurrent but not delayed associations between life stressors and depressive symptoms: a microlongitudinal study.

    PubMed

    Dautovich, Natalie D; Dzierzewski, Joseph M; Gum, Amber M

    2014-11-01

    The present study investigated the temporal association between life event stressors relevant to older adults and depressive symptoms using a micro-longitudinal design (i.e., monthly increments over a six-month period). Existing research on stress and depressive symptoms has not examined this association over shorter time periods (e.g., monthly), over multiple time increments, or within-persons. An in-person initial interview was followed by six monthly interviews conducted by telephone. Community. Data were drawn from a study of 144 community-dwelling older adults with depressive symptoms. Stressful life events were measured using the Geriatric Life Events Scale (GALES), and depressive symptoms were assessed with the Short - Geriatric Depression Scale (S-GDS). Using multilevel modeling, 31% of the S-GDS' and 39% of the GALES' overall variance was due to within-person variability. Females and persons with worse health reported more depressive symptoms. Stressful life events predicted concurrent depressive symptoms, but not depressive symptoms one month later. The lack of a time-lagged relationship suggests that older adults with depressive symptoms may recover more quickly from life stressors than previously thought, although additional research using varying time frames is needed to pinpoint the timing of this recovery as well as to identify older adults at risk of long-term effects of life stressors. Copyright © 2014 American Association for Geriatric Psychiatry. All rights reserved.

  4. Quantification of cell cycle kinetics by EdU (5-ethynyl-2′-deoxyuridine)-coupled-fluorescence-intensity analysis

    PubMed Central

    Cabrita, Marisa; Bekman, Evguenia; Braga, José; Rino, José; Santus, Renè; Filipe, Paulo L.; Sousa, Ana E.; Ferreira, João A.

    2017-01-01

    We propose a novel single-deoxynucleoside-based assay that is easy to perform and provides accurate values for the absolute length (in units of time) of each of the cell cycle stages (G1, S and G2/M). This flow-cytometric assay takes advantage of the excellent stoichiometric properties of azide-fluorochrome detection of DNA substituted with 5-ethynyl-2′-deoxyuridine (EdU). We show that by pulsing cells with EdU for incremental periods of time maximal EdU-coupled fluorescence is reached when pulsing times match the length of S phase. These pulsing times, allowing labelling for a full S phase of a fraction of cells in asynchronous populations, provide accurate values for the absolute length of S phase. We characterized additional, lower intensity signals that allowed quantification of the absolute durations of G1 and G2 phases. Importantly, using this novel assay data on the lengths of G1, S and G2/M phases are obtained in parallel. Therefore, these parameters can be estimated within a time frame that is shorter than a full cell cycle. This method, which we designate as EdU-Coupled Fluorescence Intensity (E-CFI) analysis, was successfully applied to cell types with distinctive cell cycle features and shows excellent agreement with established methodologies for analysis of cell cycle kinetics. PMID:28465489

  5. Predictors of shorter sleep in early childhood

    PubMed Central

    McDonald, Laura; Wardle, Jane; Llewellyn, Clare H.; van Jaarsveld, Cornelia H.M.; Fisher, Abigail

    2014-01-01

    Objective The aim of this study was to identify socio-demographic and home environmental predictors of shorter sleep in early childhood, and to examine whether effects were mediated by the timing of bedtime or wake time. Methods Participants were from Gemini, a British birth cohort of twins, and included 1702 children; one randomly selected from each twin pair. Parents reported night-time sleep duration at an average age of 15.8 months (range 14–27 months) using a modified version of the Brief Infant Sleep Questionnaire. Multiple logistic regression models were used to identify predictors of shorter sleep for this study. Results Using a cut-off of <11 h a night, shorter sleep was reported in 14.1% of children. Lower maternal education, non-white ethnic background, being male, low birth weight, living in a home with >1 older child and watching >1 h of TV in the evening were independently associated with shorter sleep. Mediation analyses showed that associations between education, ethnicity, evening TV viewing and sleep were driven predominantly by later bedtimes, while sex differences were driven predominantly by earlier wake times in boys. Conclusion In this sample, multiple environmental factors were associated with shorter sleep in young children, with several operating predominantly through later bedtime. An emphasis on the importance of an early and consistent bedtime could help promote healthy sleep and reduce inequalities in child health. PMID:24726571

  6. NMR signals within the generalized Langevin model for fractional Brownian motion

    NASA Astrophysics Data System (ADS)

    Lisý, Vladimír; Tóthová, Jana

    2018-03-01

    The methods of Nuclear Magnetic Resonance belong to the best developed and often used tools for studying random motion of particles in different systems, including soft biological tissues. In the long-time limit the current mathematical description of the experiments allows proper interpretation of measurements of normal and anomalous diffusion. The shorter-time dynamics is however correctly considered only in a few works that do not go beyond the standard memoryless Langevin description of the Brownian motion (BM). In the present work, the attenuation function S (t) for an ensemble of spin-bearing particles in a magnetic-field gradient, expressed in a form applicable for any kind of stationary stochastic dynamics of spins with or without a memory, is calculated in the frame of the model of fractional BM. The solution of the model for particles trapped in a harmonic potential is obtained in an exceedingly simple way and used for the calculation of S (t). In the limit of free particles coupled to a fractal heat bath, the results compare favorably with experiments acquired in human neuronal tissues. The effect of the trap is demonstrated by introducing a simple model for the generalized diffusion coefficient of the particle.

  7. Development and performance assessment of a luminex xMAP® direct hybridization assay for the detection and identification of indoor air fungal contamination.

    PubMed

    Libert, Xavier; Packeu, Ann; Bureau, Fabrice; Roosens, Nancy H; De Keersmaecker, Sigrid C J

    2017-01-01

    Considered as a public health problem, indoor fungal contamination is generally monitored using classical protocols based on culturing. However, this culture dependency could influence the representativeness of the fungal population detected in an analyzed sample as this includes the dead and uncultivable fraction. Moreover, culture-based protocols are often time-consuming. In this context, molecular tools are a powerful alternative, especially those allowing multiplexing. In this study a Luminex xMAP® assay was developed for the simultaneous detection of 10 fungal species which are most frequently in indoor air and that may cause health problems. This xMAP® assay was found to be sensitive, i.e. its limit of detection is ranging between 0.05 and 0.01 ng of gDNA. The assay was subsequently tested with environmental air samples which were also analyzed with a classical protocol. All the species identified with the classical method were also detected with the xMAP® assay, however in a shorter time frame. These results demonstrate that the Luminex xMAP® fungal assay developed in this study could contribute to the improvement of public health and specifically to the indoor fungal contamination treatment.

  8. Sound Clocks and Sonic Relativity

    NASA Astrophysics Data System (ADS)

    Todd, Scott L.; Menicucci, Nicolas C.

    2017-10-01

    Sound propagation within certain non-relativistic condensed matter models obeys a relativistic wave equation despite such systems admitting entirely non-relativistic descriptions. A natural question that arises upon consideration of this is, "do devices exist that will experience the relativity in these systems?" We describe a thought experiment in which `acoustic observers' possess devices called sound clocks that can be connected to form chains. Careful investigation shows that appropriately constructed chains of stationary and moving sound clocks are perceived by observers on the other chain as undergoing the relativistic phenomena of length contraction and time dilation by the Lorentz factor, γ , with c the speed of sound. Sound clocks within moving chains actually tick less frequently than stationary ones and must be separated by a shorter distance than when stationary to satisfy simultaneity conditions. Stationary sound clocks appear to be length contracted and time dilated to moving observers due to their misunderstanding of their own state of motion with respect to the laboratory. Observers restricted to using sound clocks describe a universe kinematically consistent with the theory of special relativity, despite the preferred frame of their universe in the laboratory. Such devices show promise in further probing analogue relativity models, for example in investigating phenomena that require careful consideration of the proper time elapsed for observers.

  9. Behavioral changes and cholinesterase activity of rats acutely treated with propoxur.

    PubMed

    Thiesen, F V; Barros, H M; Tannhauser, M; Tannhauser, S L

    1999-01-01

    Early assessment of neurological and behavioral effects is extremely valuable for early identification of intoxications because preventive measures can be taken against more severe or chronic toxic consequences. The time course of the effects of an oral dose of the anticholinesterase agent propoxur (8.3 mg/kg) was determined on behaviors displayed in the open-field and during an active avoidance task by rats and on blood and brain cholinesterase activity. Maximum inhibition of blood cholinesterase was observed within 30 min after administration of propoxur. The half-life of enzyme-activity recovery was estimated to be 208.6 min. Peak brain cholinesterase inhibition was also detected between 5 and 30 min of the pesticide administration, but the half-life for enzyme activity recovery was much shorter, in the range of 85 min. Within this same time interval of the enzyme effects, diminished motor and exploratory activities and decreased performance of animals in the active avoidance task were observed. Likewise, behavioral normalization after propoxur followed a time frame similar to that of brain cholinesterase. These data indicate that behavioral changes that occur during intoxication with low oral doses of propoxur may be dissociated from signs characteristic of cholinergic over-stimulation but accompany brain cholinesterase activity inhibition.

  10. Relationship between linear type and fertility traits in Nguni cows.

    PubMed

    Zindove, T J; Chimonyo, M; Nephawe, K A

    2015-06-01

    The objective of the study was to assess the dimensionality of seven linear traits (body condition score, body stature, body length, heart girth, navel height, body depth and flank circumference) in Nguni cows using factor analysis and indicate the relationship between the extracted latent variables and calving interval (CI) and age at first calving (AFC). The traits were measured between December 2012 and November 2013 on 1559 Nguni cows kept under thornveld, succulent karoo, grassland and bushveld vegetation types. Low partial correlations (-0.04 to 0.51), high Kaiser statistic for measure of sampling adequacy scores and significance of the Bartlett sphericity test (P1. Factor 1 included body condition score, body depth, flank circumference and heart girth and represented body capacity of cows. Factor 2 included body length, body stature and navel height and represented frame size of cows. CI and AFC decreased linearly with increase of factor 1. There was a quadratic increase in AFC as factor 2 increased (P<0.05). It was concluded that the linear type traits under study can be grouped into two distinct factors, one linked to body capacity and the other to the frame size of the cows. Small-framed cows with large body capacities have shorter CI and AFC.

  11. Coincidence ion imaging with a fast frame camera

    NASA Astrophysics Data System (ADS)

    Lee, Suk Kyoung; Cudry, Fadia; Lin, Yun Fei; Lingenfelter, Steven; Winney, Alexander H.; Fan, Lin; Li, Wen

    2014-12-01

    A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.

  12. A low-noise 15-μm pixel-pitch 640×512 hybrid InGaAs image sensor for night vision

    NASA Astrophysics Data System (ADS)

    Guellec, Fabrice; Dubois, Sébastien; de Borniol, Eric; Castelein, Pierre; Martin, Sébastien; Guiguet, Romain; Tchagaspanian, Micha"l.; Rouvié, Anne; Bois, Philippe

    2012-03-01

    Hybrid InGaAs focal plane arrays are very interesting for night vision because they can benefit from the nightglow emission in the Short Wave Infrared band. Through a collaboration between III-V Lab and CEA-Léti, a 640x512 InGaAs image sensor with 15μm pixel pitch has been developed. The good crystalline quality of the InGaAs detectors opens the door to low dark current (around 20nA/cm2 at room temperature and -0.1V bias) as required for low light level imaging. In addition, the InP substrate can be removed to extend the detection range towards the visible spectrum. A custom readout IC (ROIC) has been designed in a standard CMOS 0.18μm technology. The pixel circuit is based on a capacitive transimpedance amplifier (CTIA) with two selectable charge-to-voltage conversion gains. Relying on a thorough noise analysis, this input stage has been optimized to deliver low-noise performance in high-gain mode with a reasonable concession on dynamic range. The exposure time can be maximized up to the frame period thanks to a rolling shutter approach. The frame rate can be up to 120fps or 60fps if the Correlated Double Sampling (CDS) capability of the circuit is enabled. The first results show that the CDS is effective at removing the very low frequency noise present on the reference voltage in our test setup. In this way, the measured total dark noise is around 90 electrons in high-gain mode for 8.3ms exposure time. It is mainly dominated by the dark shot noise for a detector temperature settling around 30°C when not cooled. The readout noise measured with shorter exposure time is around 30 electrons for a dynamic range of 71dB in high-gain mode and 108 electrons for 79dB in low-gain mode.

  13. Toward the greening of nuclear energy: A content analysis of nuclear energy frames from 1991 to 2008

    NASA Astrophysics Data System (ADS)

    Miller, Sonya R.

    Framing theory has emerged as one of the predominant theories employed in mass communications research in the 21st century. Frames are identified as interpretive packages for content where some issue attributes are highlighted over other attributes. While framing effects studies appear plentiful, longitudinal studies assessing trends in dominant framing packages and story elements for an issue appear to be less understood. Through content analysis, this study examines dominant frame packages, story elements, headline tone, story tone, stereotypes, and source attribution for nuclear energy from 1991-2008 in the New York Times, USA Today, the Wall Street Journal, and the Washington Post. Unlike many content analysis studies, this study compares intercoder reliability among three indices---percentage agreement, proportional reduction of loss and Scott's Pi. The newspapers represented in this study possess a commonality in the types of dominant frames packages employed. Significant dominant frame packages among the four newspapers include human/health, proliferation, procedural, and marketplace. While the procedural frame package was more likely to appear prior to the 1997 Kyoto Protocol, the proliferation frame packaged was more likely to appear after the Kyoto Protol. Over time, the sustainable frame package demonstrated increased significance. This study is part of the growing literature regarding the function of frames over time.

  14. Role of "the frame cycle time" in portal dose imaging using an aS500-II EPID.

    PubMed

    Al Kattar Elbalaa, Zeina; Foulquier, Jean Noel; Orthuon, Alexandre; Elbalaa, Hanna; Touboul, Emmanuel

    2009-09-01

    This paper evaluates the role of an acquisition parameter, the frame cycle time "FCT", in the performance of an aS500-II EPID. The work presented rests on the study of the Varian EPID aS500-II and the image acquisition system 3 (IAS3). We are interested in integrated acquisition using asynchronous mode. For better understanding the image acquisition operation, we investigated the influence of the "frame cycle time" on the speed of acquisition, the pixel value of the averaged gray-scale frame and the noise, using 6 and 15MV X-ray beams and dose rates of 1-6Gy/min on 2100 C/D Linacs. In the integrated mode not synchronized to beam pulses, only one parameter the frame cycle time "FCT" influences the pixel value. The pixel value of the averaged gray-scale frame is proportional to this parameter. When the FCT <55ms (speed of acquisition V(f/s)>18 frames/s), the speed of acquisition becomes unstable and leads to a fluctuation of the portal dose response. A timing instability and saturation are detected when the dose per frame exceeds 1.53MU/frame. Rules were deduced to avoid saturation and to optimize this dosimetric mode. The choice of the acquisition parameter is essential for the accurate portal dose imaging.

  15. 40 CFR 35.110 - Time frame for EPA action.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 1 2012-07-01 2012-07-01 false Time frame for EPA action. 35.110... ASSISTANCE STATE AND LOCAL ASSISTANCE Environmental Program Grants Epa Action on Application § 35.110 Time frame for EPA action. The Regional Administrator will review a complete application and either approve...

  16. 40 CFR 35.105 - Time frame for submitting an application.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Time frame for submitting an application. 35.105 Section 35.105 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER....105 Time frame for submitting an application. An applicant should submit a complete application to EPA...

  17. 42 CFR 405.922 - Time frame for processing initial determinations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Time frame for processing initial determinations. 405.922 Section 405.922 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH... § 405.922 Time frame for processing initial determinations. The contractor issues initial determinations...

  18. 40 CFR 35.506 - Time frame for submitting an application.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Time frame for submitting an application. 35.506 Section 35.506 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER... Application § 35.506 Time frame for submitting an application. An applicant should submit a complete...

  19. 40 CFR 35.510 - Time frame for EPA action.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Time frame for EPA action. 35.510 Section 35.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL....510 Time frame for EPA action. The Regional Administrator will review a complete application and...

  20. 40 CFR 35.510 - Time frame for EPA action.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Time frame for EPA action. 35.510 Section 35.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL....510 Time frame for EPA action. The Regional Administrator will review a complete application and...

  1. 40 CFR 35.510 - Time frame for EPA action.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 1 2012-07-01 2012-07-01 false Time frame for EPA action. 35.510 Section 35.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL....510 Time frame for EPA action. The Regional Administrator will review a complete application and...

  2. I spy with my little eye: cognitive processing of framed physical activity messages.

    PubMed

    Bassett-Gunter, Rebecca L; Latimer-Cheung, Amy E; Martin Ginis, Kathleen A; Castelhano, Monica

    2014-01-01

    The primary purpose was to examine the relative cognitive processing of gain-framed versus loss-framed physical activity messages following exposure to health risk information. Guided by the Extended Parallel Process Model, the secondary purpose was to examine the relation between dwell time, message recall, and message-relevant thoughts, as well as perceived risk, personal relevance, and fear arousal. Baseline measures of perceived risk for inactivity-related disease and health problems were administered to 77 undergraduate students. Participants read population-specific health risk information while wearing a head-mounted eye tracker, which measured dwell time on message content. Perceived risk was then reassessed. Next, participants read PA messages while the eye tracker measured dwell time on message content. Immediately following message exposure, recall, thought-listing, fear arousal, and personal relevance were measured. Dwell time on gain-framed messages was significantly greater than loss-framed messages. However, message recall and thought-listing did not differ by message frame. Dwell time was not significantly related to recall or thought-listing. Consistent with the Extended Parallel Process Model, fear arousal was significantly related to recall, thought-listing, and personal relevance. In conclusion, gain-framed messages may evoke greater dwell time than loss-famed messages. However, dwell time alone may be insufficient for evoking further cognitive processing.

  3. 76 FR 67343 - Airworthiness Directives; The Boeing Company Model 737-300, -400, and -500 Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-01

    ... times for those actions. This AD was prompted by reports of cracking in the frame, or in the frame and frame reinforcement, common to the 1.04- inch nominal diameter wire penetration hole intended for wire routing; and recent reports of multiple adjacent frame cracking found before the compliance time required...

  4. The Contribution of Thermally-Pulsing Asymptotic Giant Branch and Red Supergiant Starts to the Luminosities of the Magellanic Clouds at 1-24 micrometers

    NASA Technical Reports Server (NTRS)

    Melbourne, J.; Boyer, Martha L.

    2013-01-01

    We present the near-through mid-infrared flux contribution of thermally-pulsing asymptotic giant branch (TP-AGB) and massive red supergiant (RSG) stars to the luminosities of the Large and Small Magellanic Clouds (LMC and SMC, respectively). Combined, the peak contribution from these cool evolved stars occurs at approx 3 - 4 micron, where they produce 32% of the SMC light, and 25% of the LMC flux. The TP-AGB star contribution also peaks at approx 3 - 4 micron and amounts to 21% in both galaxies. The contribution from RSG stars peaks at shorter wavelengths, 2.2 micron, where they provide 11% of the SMC flux, and 7% for the LMC. Both TP-AGB and RSG stars are short lived, and thus potentially impose a large stochastic scatter on the near-IR derived mass-to-light (M/L) ratios of galaxies at rest-frame 1 - 4 micron. To minimize their impact on stellar mass estimates, one can use the M/L ratio at shorter wavelengths (e.g., at 0.8 - 1 micron). At longer wavelengths (much > 8 micron), emission from dust in the interstellar medium dominates the flux. In the LMC, which shows strong polycyclic aromatic hydrocarbon (PAH) emission at 8 micron, TP-AGB and RSG contribute less than 4% of the 8 micron flux. However, 19% of the SMC 8 micron flux is from evolved stars, nearly half of which is produced by the rarest, dustiest, carbon-rich TP-AGB stars. Thus, star formation rates of galaxies, based on an 8 micron flux (e.g., observed-frame 24 micron at z = 2), may be biased modestly high, especially for galaxies with little PAH emission.

  5. Evaluating the Human Damage of Tsunami at Each Time Frame in Aggregate Units Based on GPS data

    NASA Astrophysics Data System (ADS)

    Ogawa, Y.; Akiyama, Y.; Kanasugi, H.; Shibasaki, R.; Kaneda, H.

    2016-06-01

    Assessments of the human damage caused by the tsunami are required in order to consider disaster prevention at such a regional level. Hence, there is an increasing need for the assessments of human damage caused by earthquakes. However, damage assessments in japan currently usually rely on static population distribution data, such as statistical night time population data obtained from national census surveys. Therefore, human damage estimation that take into consideration time frames have not been assessed yet. With these backgrounds, the objectives of this study are: to develop a method for estimating the population distribution of the for each time frame, based on location positioning data observed with mass GPS loggers of mobile phones, to use a evacuation and casualties models for evaluating human damage due to the tsunami, and evaluate each time frame by using the data developed in the first objective, and 3) to discuss the factors which cause the differences in human damage for each time frame. By visualizing the results, we clarified the differences in damage depending on time frame, day and area. As this study enables us to assess damage for any time frame in and high resolution, it will be useful to consider provision for various situations when an earthquake may hit, such as during commuting hours or working hours and week day or holiday.

  6. Results from the JPL IGS Analysis Center IGS14 Reprocessing Campaign

    NASA Astrophysics Data System (ADS)

    Ries, P. A.; Amiri, N.; Heflin, M. B.; Sakumura, C.; Sibois, A. E.; Sibthorpe, A.; David, M. W.

    2017-12-01

    The JPL IGS analysis center has begun a campaign to reprocess GPS orbits and clocks in the IGS14 reference frame. Though the new frame is only a few millimeters offset from the previous IGb08 frame, a reprocessing is required for consistent use of the new frame due to a change in the satellite phase center offsets between the frames. We will present results on the reprocessing campaign from 2002 to present in order to evaluate any effects caused by the new frame. We also create long-term time-series and periodograms of translation, rotation, and scale parameters to see if there is any divergence between the frames. We will also process long-term PPP time series and derived velocities for a well-distributed set of stations in each frame to compare with the published frame offsets.

  7. Hardware accelerator design for tracking in smart camera

    NASA Astrophysics Data System (ADS)

    Singh, Sanjay; Dunga, Srinivasa Murali; Saini, Ravi; Mandal, A. S.; Shekhar, Chandra; Vohra, Anil

    2011-10-01

    Smart Cameras are important components in video analysis. For video analysis, smart cameras needs to detect interesting moving objects, track such objects from frame to frame, and perform analysis of object track in real time. Therefore, the use of real-time tracking is prominent in smart cameras. The software implementation of tracking algorithm on a general purpose processor (like PowerPC) could achieve low frame rate far from real-time requirements. This paper presents the SIMD approach based hardware accelerator designed for real-time tracking of objects in a scene. The system is designed and simulated using VHDL and implemented on Xilinx XUP Virtex-IIPro FPGA. Resulted frame rate is 30 frames per second for 250x200 resolution video in gray scale.

  8. A Possible Approach to Inclusion of Space and Time in Frame Fields of Quantum Representations of Real and Complex Numbers

    DOE PAGES

    Benioff, Paul

    2009-01-01

    Tmore » his work is based on the field of reference frames based on quantum representations of real and complex numbers described in other work. Here frame domains are expanded to include space and time lattices. Strings of qukits are described as hybrid systems as they are both mathematical and physical systems. As mathematical systems they represent numbers. As physical systems in each frame the strings have a discrete Schrodinger dynamics on the lattices. he frame field has an iterative structure such that the contents of a stage j frame have images in a stage j - 1 (parent) frame. A discussion of parent frame images includes the proposal that points of stage j frame lattices have images as hybrid systems in parent frames. he resulting association of energy with images of lattice point locations, as hybrid systems states, is discussed. Representations and images of other physical systems in the different frames are also described.« less

  9. 78 FR 46528 - Surety Bond Guarantee Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-01

    ... proposing to reduce the time frame allowed for a Surety to reimburse or credit SBA for salvage and recovery... the time frame reference required by the Recovery Act, which has expired, and by inserting the...)(1). SBA is proposing to reduce the time frame allowed for a Prior Approval Surety to submit a claim...

  10. 5 CFR 890.807 - When do enrollments terminate, cancel or suspend?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... on whose service the health benefits are based. (2) OPM may authorize a longer time frame for the...) Termination of enrollment for failure to pay premiums within the time frame established in accordance with... the enrollment of a former spouse who fails to make an election within the specified time frame will...

  11. 21 CFR 60.28 - Time frame for determining regulatory review periods.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Time frame for determining regulatory review periods. 60.28 Section 60.28 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL PATENT TERM RESTORATION Regulatory Review Period Determinations § 60.28 Time frame for...

  12. 42 CFR 403.251 - Loss ratio date and time frame provisions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Loss ratio date and time frame provisions. 403.251 Section 403.251 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... Certification Program: Loss Ratio Provisions § 403.251 Loss ratio date and time frame provisions. (a) Initial...

  13. Coincidence ion imaging with a fast frame camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Suk Kyoung; Cudry, Fadia; Lin, Yun Fei

    2014-12-15

    A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots onmore » each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.« less

  14. Time scales of porphyry Cu deposit formation: insights from titanium diffusion in quartz

    USGS Publications Warehouse

    Mercer, Celestine N.; Reed, Mark H.; Mercer, Cameron M.

    2015-01-01

    Porphyry dikes and hydrothermal veins from the porphyry Cu-Mo deposit at Butte, Montana, contain multiple generations of quartz that are distinct in scanning electron microscope-cathodoluminescence (SEM-CL) images and in Ti concentrations. A comparison of microprobe trace element profiles and maps to SEM-CL images shows that the concentration of Ti in quartz correlates positively with CL brightness but Al, K, and Fe do not. After calibrating CL brightness in relation to Ti concentration, we use the brightness gradient between different quartz generations as a proxy for Ti gradients that we model to determine time scales of quartz formation and cooling. Model results indicate that time scales of porphyry magma residence are ~1,000s of years and time scales from porphyry quartz phenocryst rim formation to porphyry dike injection and cooling are ~10s of years. Time scales for the formation and cooling of various generations of hydrothermal vein quartz range from 10s to 10,000s of years. These time scales are considerably shorter than the ~0.6 m.y. overall time frame for each porphyry-style mineralization pulse determined from isotopic studies at Butte, Montana. Simple heat conduction models provide a temporal reference point to compare chemical diffusion time scales, and we find that they support short dike and vein formation time scales. We interpret these relatively short time scales to indicate that the Butte porphyry deposit formed by short-lived episodes of hydrofracturing, dike injection, and vein formation, each with discrete thermal pulses, which repeated over the ~3 m.y. generation of the deposit.

  15. Waiting times for hospital admissions: the impact of GP fundholding.

    PubMed

    Propper, Carol; Croxson, Bronwyn; Shearer, Arran

    2002-03-01

    Waiting times for hospital care are a significant issue in the UK National Health Service (NHS). The reforms of the health service in 1990 gave a subset of family doctors (GP fundholders) both the ability to choose the hospital where their patients were treated and the means to pay for some services. One of the key factors influencing family doctors' choice of hospital was patient waiting time. However, without cash inducements, hospitals would get no direct reward from giving shorter waiting times to a subset of patients. Using a unique dataset, we investigate whether GP fundholders were able to secure shorter waiting times for their patients, whether they were able to do so in cases where they had no financial rewards to offer hospitals, and whether the impact of fundholding spilled over into shorter waiting times for all patients.

  16. Coincidence electron/ion imaging with a fast frame camera

    NASA Astrophysics Data System (ADS)

    Li, Wen; Lee, Suk Kyoung; Lin, Yun Fei; Lingenfelter, Steven; Winney, Alexander; Fan, Lin

    2015-05-01

    A new time- and position- sensitive particle detection system based on a fast frame CMOS camera is developed for coincidence electron/ion imaging. The system is composed of three major components: a conventional microchannel plate (MCP)/phosphor screen electron/ion imager, a fast frame CMOS camera and a high-speed digitizer. The system collects the positional information of ions/electrons from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of MCPs processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of electron/ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide. We further show that a time resolution of 30 ps can be achieved when measuring electron TOF spectrum and this enables the new system to achieve a good energy resolution along the TOF axis.

  17. 7 CFR 58.101 - Meaning of words.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... solution for the destruction of most human pathogens and other vegetative microorganisms to a level... the milk product, or the health of consumers. Sanitizing solutions shall comply with 21 CFR 178.1010... (higher heat shorter time pasteurization) 1.0 second. 194 °F (higher heat shorter time pasteurization) 0.5...

  18. 7 CFR 58.101 - Meaning of words.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... solution for the destruction of most human pathogens and other vegetative microorganisms to a level... the milk product, or the health of consumers. Sanitizing solutions shall comply with 21 CFR 178.1010... (higher heat shorter time pasteurization) 1.0 second. 194 °F (higher heat shorter time pasteurization) 0.5...

  19. 7 CFR 58.101 - Meaning of words.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... solution for the destruction of most human pathogens and other vegetative microorganisms to a level... the milk product, or the health of consumers. Sanitizing solutions shall comply with 21 CFR 178.1010... (higher heat shorter time pasteurization) 1.0 second. 194 °F (higher heat shorter time pasteurization) 0.5...

  20. 45 CFR 287.55 - What time frames and guidelines apply regarding the obligation and liquidation periods for NEW...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false What time frames and guidelines apply regarding... NEW Program Funding § 287.55 What time frames and guidelines apply regarding the obligation and... be returned to the Federal government through the issuance of a negative grant award. Unobligated...

  1. 26 CFR 301.6343-1 - Requirement to release levy and notice of release.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... expedited determination, the taxpayer must submit, within the time frame specified in paragraph (c)(2) of... cases where a request for release of a levy is made within the time frame specified in paragraph (c)(2... time frame specified in paragraph (c)(2) of this section, the information required in paragraph (c)(1...

  2. 20 CFR 30.421 - What are the time frames for submitting bills and reimbursement requests?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false What are the time frames for submitting bills and reimbursement requests? 30.421 Section 30.421 Employees' Benefits OFFICE OF WORKERS' COMPENSATION... AMENDED Medical and Related Benefits Medical Bills § 30.421 What are the time frames for submitting bills...

  3. 20 CFR 10.336 - What are the time frames for submitting bills?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false What are the time frames for submitting bills? 10.336 Section 10.336 Employees' Benefits OFFICE OF WORKERS' COMPENSATION PROGRAMS, DEPARTMENT OF...' COMPENSATION ACT, AS AMENDED Medical and Related Benefits Medical Bills § 10.336 What are the time frames for...

  4. Understanding the exposure-time effect on speckle contrast measurements for laser displays

    NASA Astrophysics Data System (ADS)

    Suzuki, Koji; Kubota, Shigeo

    2018-02-01

    To evaluate the influence of exposure time on speckle noise for laser displays, speckle contrast measurement method was developed observable at a human eye response time using a high-sensitivity camera which has a signal multiplying function. The nonlinearity of camera light sensitivity was calibrated to measure accurate speckle contrasts, and the measuring lower limit noise of speckle contrast was improved by applying spatial-frequency low pass filter to the captured images. Three commercially available laser displays were measured over a wide range of exposure times from tens of milliseconds to several seconds without adjusting the brightness of laser displays. The speckle contrast of raster-scanned mobile projector without any speckle-reduction device was nearly constant over various exposure times. On the contrary to this, in full-frame projection type laser displays equipped with a temporally-averaging speckle-reduction device, some of their speckle contrasts close to the lower limits noise were slightly increased at the shorter exposure time due to the noise. As a result, the exposure-time effect of speckle contrast could not be observed in our measurements, although it is more reasonable to think that the speckle contrasts of laser displays, which are equipped with the temporally-averaging speckle-reduction device, are dependent on the exposure time. This discrepancy may be attributed to the underestimation of temporal averaging factor. We expected that this method is useful for evaluating various laser displays and clarify the relationship between the speckle noise and the exposure time for a further verification of speckle reduction.

  5. [Effectiveness of eyeglasses for protection against ultraviolet rays].

    PubMed

    Sakamoto, Y; Kojima, M; Sasaki, K

    1999-05-01

    The relationship between eyeglass size and protection of the eye surface from the effects of solar ultraviolet (UV) rays was investigated. Solar UV rays irradiating the eye surface were measured on a mannequin which modeled the standard facial bone structure of a Japanese female. UV sensor chips (photo-sensitivity: 260-400 nm) were attached to the ocular surface of the lid fissure. UV measurement was done from 12:00 to 15:00 on a sunny day in March. UV intensity was measured under the following conditions: 1) with or without eyeglasses, 2) wearing sunglasses with side protectors, and 3) wearing a cap with a 7 cm brim. Eyeglasses of four frame sizes (width: 48-57 mm) were put on the mannequin. All lenses were made of plastic and coated so as to be impervious to rays shorter than 400 nm. The refractive power was 0 diopters. At the same time, UV irradiation intensity from all directions (excluding from the earth direction) was measured using a polyhedron type UV sensor with 25 sensor chips. Except for eyeglasses with the smallest frame size, eyeglasses effectively reduced UV exposure to sunlight from the upper front direction. However, protection against rays from the upper temporal direction was extremely poor. Sunlight from the upper back was reflected by the posterior surface of the eyeglasses and reached the eye surface. The efficacy of eyeglasses against UV depends on their size. The shape of the eyeglasses and reflection from the posterior lens surface are also of great importance. Small eyeglasses do not offer ideal UV protection for the Japanese face shape.

  6. Relative linkages of peatland methane and carbon dioxide fluxes with climatic, environmental and ecological parameters and their inter-comparison

    NASA Astrophysics Data System (ADS)

    Banerjee, Tirtha; Hommeltenberg, Janina; Roy, Avipsa; De Roo, Frederik; Mauder, Matthias

    2016-04-01

    Although methane (CH4) is the second most important greenhouse gas (GHG) after CO2, about 80% of its global production is biogenic (wetlands, enteric fermentation and water disposal from animals) contrary to major anthropogenic sources of most other GHGs. Although on a shorter time scale, global emissions of methane are greater (10 year time frame) or about 80% (20 year time frame) of those of carbon dioxide in terms of their influence on global warming, methane emissions have been studied much less than CO2 emissions. Lakes, reservoirs and wetlands are estimated to contribute about 15-40% to the global methane source budget, which is higher than total oceanic CH4 emission. Half of the world's wetlands are represented by peatlands which cover 3% of the global total land area. Peatlands have a thick water-logged organic soil layer (peat) made up of dead and decaying plant material. Moreover, they are carbon rich, containing twice as much stock as the entire forest biomass of the world (550 Gt carbon). When disturbed, they can become significant sources of greenhouse gas emissions. The organic carbon exposed to air due to various mechanisms can release CH4 or CO2 in the atmosphere. Thus the nature of vegetation cover, radiation environment, wind turbulence, soil characteristics, water table depth etc. are expected to be important forcings that influence the emission of CH4 or CO2 in the shorter time scale. However, long term climate change can also influence these governing factors themselves over a larger time scale, which in turn can influence the wetland GHG emissions. Thus developing a predictive framework and long term source appropriation for wetland CH4 or CO2 warrants an identification of the major environmental forcings on the CH4 or CO2 flux. In the present work, we use a simple and systematic data-analytics approach to determine the relative linkages of different climate and environmental variables with the canopy level half-hourly CH4 or CO2 fluxes over a peatland in Germany. We utilize multivariate pattern recognition techniques of principle component and factor analysis to group and classify climatic, environmental and ecological variables based on their similarity as drivers. Three biophysical process components emerge from the clustering analysis which describe the system-data variances. We find that soil conditions (soil temperature and soil heat flux) are most important in explaining the CH4 flux. The radiation and energy components (sensible heat flux, photosynthetically active radiation (PAR), latent heat flux, net radiation) and turbulence components (wind speed, friction velocity) are moderately linked with the CH4 flux. On the other hand, the CO2 flux has poor linkage with the soil environment variables, while it is strongly linked with the radiation environment components and the turbulence parameters. Quantifying these linkages using factor analysis can be up-scaled to include decadal scale variability to study the effect of climate change on wetland GHG emissions as well.

  7. Optimizing the night time with dome vents and SNR-QSO at CFHT

    NASA Astrophysics Data System (ADS)

    Devost, Daniel; Mahoney, Billy; Moutou, Claire; CFHT QSO Team, CFHT software Group

    2017-06-01

    Night time is a precious and costly commodity and it is important to get everything we can out of every second of every night of observing. In 2012 the Canada-France-Hawaii Telescope started operating 12 new vent doors installed on the dome over the course of the previous two years. The project was highly successful and seeing measurements show that venting the dome greatly enhances image quality at the focal plane. In order to capitalize on the gains brought by the new vents, the observatory started exploring a new mode of observation called SNR-QSO. This mode consist of a new implementation inside our Queued Service Observation (QSO) system. Exposure times are adjusted for each frame depending on the weather conditions in order to reach a specific depth, Signal to Noise Ratio (SNR) at a certain magnitude. The goal of this new mode is to capitalize on the exquisite seeing provided by Maunakea, complemented by the minimized dome turbulence, to use the least amount of time to reach the depth required by the science programs. Specific implementations were successfully tested on two different instruments, our wide field camera MegaCam and our high resolution spectrograph ESPaDOnS. I will present the methods used for each instrument to achieve SNR observing and the gains produced by these new observing modes in order to reach the scientific goals of accepted programs in a shorter amount of time.

  8. 20 CFR 666.205 - What are the time frames under which States submit performance progress reports and apply for...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false What are the time frames under which States submit performance progress reports and apply for incentive grants? 666.205 Section 666.205 Employees... the time frames under which States submit performance progress reports and apply for incentive grants...

  9. Regenerative responses after mild heart injuries for cardiomyocyte proliferation in zebrafish

    PubMed Central

    Itou, Junji; Akiyama, Ryutaro; Pehoski, Steve; Yu, Xiaodan; Kawakami, Hiroko; Kawakami, Yasuhiko

    2014-01-01

    Background The zebrafish heart regenerates after various severe injuries. Common processes of heart regeneration are cardiomyocyte proliferation, activation of epicardial tissue and neovascularization. In order to further characterize heart regeneration processes, we introduced milder injuries and compared responses to those induced by ventricular apex resection, a widely used injury method. We used scratching of the ventricular surface and puncturing of the ventricle with a fine tungsten needle as injury inducing techniques. Results Scratching the ventricular surface induced subtle cardiomyocyte proliferation and responses of the epicardium. Endothelial cell accumulation was limited to the surface of the heart. Ventricular puncture induced cardiomyocyte proliferation, endocardial and epicardial activation and neo-vascularization, similar to the resection method. However, the degree of the responses was milder, correlating with milder injury. Sham operation induced epicardial aldh1a2 expression but not tbx18 and WT1. Conclusions Puncturing the ventricle induces responses equivalent to resection at milder degrees in a shorter time frame and would be used as simple injury model. Scratching the ventricle did not induce heart regeneration and would be used for studying wound responses to epicardium. PMID:25074230

  10. Modeling of a microchannel plate working in pulsed mode

    NASA Astrophysics Data System (ADS)

    Secroun, Aurelia; Mens, Alain; Segre, Jacques; Assous, Franck; Piault, Emmanuel; Rebuffie, Jean-Claude

    1997-05-01

    MicroChannel Plates (MCPs) are used in high speed cinematography systems such as MCP framing cameras and streak camera readouts. In order to know the dynamic range or the signal to noise ratio that are available in these devices, a good knowledge of the performances of the MCP is essential. The point of interest of our simulation is the working mode of the microchannel plate--that is light pulsed mode--, in which the signal level is relatively high and its duration can be shorter than the time needed to replenish the wall of the channel, when other papers mainly studied night vision applications with weak continuous and nearly single electron input signal. Also our method allows the simulation of saturation phenomena due to the large number of electrons involved, whereas the discrete models previously used for simulating pulsed mode might not be properly adapted. Here are presented the choices made in modeling the microchannel, more specifically as for the physics laws, the secondary emission parameters and the 3D- geometry. In a last part first results are shown.

  11. Novel transcripts of the estrogen receptor α gene in channel catfish

    USGS Publications Warehouse

    Patino, Reynaldo; Xia, Zhenfang; Gale, William L.; Wu, Chunfa; Maule, Alec G.; Chang, Xiaotian

    2000-01-01

    Complementary DNA libraries from liver and ovary of an immature female channel catfish were screened with a homologous ERα cDNA probe. The hepatic library yielded two new channel catfish ER cDNAs that encode N-terminal ERα variants of different sizes. Relative to the catfish ERα (medium size; 581 residues) previously reported, these new cDNAs encode Long-ERα (36 residues longer) and Short-ERα (389 residues shorter). The 5′-end of Long-ERα cDNA is identical to that of Medium-ERα but has an additional 503-bp segment with an upstream, in-frame translation-start codon. Recombinant Long-ERα binds estrogen with high affinity (Kd = 3.4 nM), similar to that previously reported for Medium-ERα but lower than reported for catfish ERβ. Short-ERα cDNA encodes a protein that lacks most of the receptor protein and does not bind estrogen. Northern hybridization confirmed the existence of multiple hepatic ERα RNAs that include the size range of the ERα cDNAs obtained from the libraries as well as additional sizes. Using primers for RT-PCR that target locations internal to the protein-coding sequence, we also established the presence of several ERα cDNA variants with in-frame insertions in the ligand-binding and DNA-binding domains and in-frame or out-of-frame deletions in the ligand-binding domain. These internal variants showed patterns of expression that differed between the ovary and liver. Further, the ovarian library yielded a full-length, ERα antisense cDNA containing a poly(A) signal and tail. A limited survey of histological preparations from juvenile catfish by in situ hybridization using directionally synthesized cRNA probes also suggested the expression of ERα antisense RNA in a tissue-specific manner. In conclusion, channel catfish seemingly have three broad classes of ERα mRNA variants: those encoding N-terminal truncated variants, those encoding internal variants (including C-terminal truncated variants), and antisense mRNA. The sense variants may encode functional ERα or related proteins that modulate ERα or ERβ activity. The existence of ER antisense mRNA is reported in this study for the first time. Its role may be to participate in the regulation of ER gene expression.

  12. [Comparison of the results of laparotomy and laparoscopic surgery in patients with Crohn's disease].

    PubMed

    Horváth, Gyula; Simonka, Zsolt; Lázár, György

    2014-01-05

    Crohn's disease is an inflammatory bowel disease which may affect different parts of the gastrointestinal tract. To compare retrospectively the results of laparotomy and laparoscopic surgery performed in patients with Crohn's disease between January 1, 2005 and October 31, 2012 in the Department of Surgery, University of Szeged, Hungary. Patients were divided into two groups based on the types of surgery; 103 patients underwent laparotomy and 30 patients had laparoscopic surgery programmed. 22 patients had 24 primary acute interventions. The mean age was significantly lower in the laparoscopic surgery group (p = 0.042). The laparoscopic ileocecal resections have been found significantly shorter than laparotomies (p = 0.033). When ileocecal resection was performed the operation time was significantly longer (p = 0.033) while hospitalization time (p = 0.025) and intensive care unit treatment time (p<0.001) were shorter and the bowel passage also started earlier in the laparoscopic group as compared to the laparotomy group. Laparoscopic surgery results in smaller surgical trauma, better cosmetic outcome, shorter hospitalization time and not higher complication- and morbidity-rate as well as shorter operation time in certain cases. However, it requires more qualified surgical team and the operation expenses are higher.

  13. Spacecraft Reed-Solomon downlink module

    NASA Technical Reports Server (NTRS)

    Luong, Huy H. (Inventor); Donaldson, James A. (Inventor); Wood, Steven H. (Inventor)

    1998-01-01

    Apparatus and method for providing downlink frames to be transmitted from a spacecraft to a ground station. Each downlink frame includes a synchronization pattern and a transfer frame. The apparatus may comprise a monolithic Reed-Solomon downlink (RSDL) encoding chip coupled to data buffers for storing transfer frames. The RSKL chip includes a timing device, a bus interface, a timing and control unit, a synchronization pattern unit, and a Reed-Solomon encoding unit, and a bus arbiter.

  14. 40 CFR 35.110 - Time frame for EPA action.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Time frame for EPA action. 35.110 Section 35.110 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL... frame for EPA action. The Regional Administrator will review a complete application and either approve...

  15. 12 CFR 1805.503 - Time frame for raising match.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Time frame for raising match. 1805.503 Section 1805.503 Banks and Banking COMMUNITY DEVELOPMENT FINANCIAL INSTITUTIONS FUND, DEPARTMENT OF THE... frame for raising match. Applicants shall satisfy matching funds requirements within the period set...

  16. Time Pressure Increases Cooperation in Competitively Framed Social Dilemmas

    PubMed Central

    Cone, Jeremy; Rand, David G.

    2014-01-01

    What makes people willing to pay costs to benefit others? Does such cooperation require effortful self-control, or do automatic, intuitive processes favor cooperation? Time pressure has been shown to increase cooperative behavior in Public Goods Games, implying a predisposition towards cooperation. Consistent with the hypothesis that this predisposition results from the fact that cooperation is typically advantageous outside the lab, it has further been shown that the time pressure effect is undermined by prior experience playing lab games (where selfishness is the more advantageous strategy). Furthermore, a recent study found that time pressure increases cooperation even in a game framed as a competition, suggesting that the time pressure effect is not the result of social norm compliance. Here, we successfully replicate these findings, again observing a positive effect of time pressure on cooperation in a competitively framed game, but not when using the standard cooperative framing. These results suggest that participants' intuitions favor cooperation rather than norm compliance, and also that simply changing the framing of the Public Goods Game is enough to make it appear novel to participants and thus to restore the time pressure effect. PMID:25551386

  17. Time pressure increases cooperation in competitively framed social dilemmas.

    PubMed

    Cone, Jeremy; Rand, David G

    2014-01-01

    What makes people willing to pay costs to benefit others? Does such cooperation require effortful self-control, or do automatic, intuitive processes favor cooperation? Time pressure has been shown to increase cooperative behavior in Public Goods Games, implying a predisposition towards cooperation. Consistent with the hypothesis that this predisposition results from the fact that cooperation is typically advantageous outside the lab, it has further been shown that the time pressure effect is undermined by prior experience playing lab games (where selfishness is the more advantageous strategy). Furthermore, a recent study found that time pressure increases cooperation even in a game framed as a competition, suggesting that the time pressure effect is not the result of social norm compliance. Here, we successfully replicate these findings, again observing a positive effect of time pressure on cooperation in a competitively framed game, but not when using the standard cooperative framing. These results suggest that participants' intuitions favor cooperation rather than norm compliance, and also that simply changing the framing of the Public Goods Game is enough to make it appear novel to participants and thus to restore the time pressure effect.

  18. Nature, nurture, or that fast food hamburger: media framing of diabetes in the New York Times from 2000 to 2010.

    PubMed

    Stefanik-Sidener, Kelsey

    2013-01-01

    Diabetes is a growing yet misunderstood health concern in the United States. This study examined the ways in which diabetes has been framed by the New York Times over the past decade. The public's perception of the causes and solutions to complex problems such as diabetes has significant implications for the way public policy interventions are viewed; therefore, understanding how diabetes is being framed in the media can be an important first step in shifting public opinion about ways to combat the disease. A content analysis of 239 articles published in the New York Times between 2000 and 2010 revealed that nearly one-third of articles failed to differentiate between type 1, type 2, and gestational diabetes, which may cause confusion given substantial differences in the root cause and treatment of each. An examination of frames used within each type of diabetes showed that the overall dominant frame across types was either a medical frame or a behavioral frame, with deficient use of a societal frame. The limited use of societal-level framing may make it difficult for the public to see the wider consequences of diabetes and decreases the likelihood of public support for policy solutions to combat the disease.

  19. Pushing x-ray photon correlation spectroscopy beyond the continuous frame rate limit

    DOE PAGES

    Dufresne, Eric M.; Narayanan, Suresh; Sandy, Alec R.; ...

    2016-01-06

    We demonstrate delayed-frame X-ray Photon Correlation Spectroscopy with 120 microsecond time resolution, limited only by sample scattering rates, with a prototype Pixel-array detector capable of taking two image frames separated by 153 ns or less. Although the overall frame rate is currently limited to about 4 frame pairs per second, we easily measured millisecond correlation functions. In conclusion, this technology, coupled to the use of brighter synchrotrons such as Petra III or the NSLS-II should enable X-ray Photon Correlation Spectroscopy on microsecond time scales on a wider variety of materials.

  20. Reference Frames in Relativistic Space-Time

    NASA Astrophysics Data System (ADS)

    Soffel, M.; Herold, H.; Ruder, H.; Schneider, M.

    Three fundamental concepts of reference frames in relativistic space-time are confronted: 1. the gravitation compass, 2. the stellar compass and 3. the inertial compass. It is argued that under certain conditions asymptotically fixed (stellar) reference frames can be introduced with the same rigour as local Fermi frames, thereby eliminating one possible psychological reason why the importance of Fermi frames frequently has been overestimated in the past. As applications of these three concepts the authors discuss: 1. a relativistic definition of the geoid, 2. a relativistic astrometric problem and 3. the post-Newtonian theory of a laser gyroscope fixed to the Earth's surface.

  1. High-frequency video capture and a computer program with frame-by-frame angle determination functionality as tools that support judging in artistic gymnastics.

    PubMed

    Omorczyk, Jarosław; Nosiadek, Leszek; Ambroży, Tadeusz; Nosiadek, Andrzej

    2015-01-01

    The main aim of this study was to verify the usefulness of selected simple methods of recording and fast biomechanical analysis performed by judges of artistic gymnastics in assessing a gymnast's movement technique. The study participants comprised six artistic gymnastics judges, who assessed back handsprings using two methods: a real-time observation method and a frame-by-frame video analysis method. They also determined flexion angles of knee and hip joints using the computer program. In the case of the real-time observation method, the judges gave a total of 5.8 error points with an arithmetic mean of 0.16 points for the flexion of the knee joints. In the high-speed video analysis method, the total amounted to 8.6 error points and the mean value amounted to 0.24 error points. For the excessive flexion of hip joints, the sum of the error values was 2.2 error points and the arithmetic mean was 0.06 error points during real-time observation. The sum obtained using frame-by-frame analysis method equaled 10.8 and the mean equaled 0.30 error points. Error values obtained through the frame-by-frame video analysis of movement technique were higher than those obtained through the real-time observation method. The judges were able to indicate the number of the frame in which the maximal joint flexion occurred with good accuracy. Using the real-time observation method as well as the high-speed video analysis performed without determining the exact angle for assessing movement technique were found to be insufficient tools for improving the quality of judging.

  2. Rapid divergence and convergence of life-history in experimentally evolved Drosophila melanogaster.

    PubMed

    Burke, Molly K; Barter, Thomas T; Cabral, Larry G; Kezos, James N; Phillips, Mark A; Rutledge, Grant A; Phung, Kevin H; Chen, Richard H; Nguyen, Huy D; Mueller, Laurence D; Rose, Michael R

    2016-09-01

    Laboratory selection experiments are alluring in their simplicity, power, and ability to inform us about how evolution works. A longstanding challenge facing evolution experiments with metazoans is that significant generational turnover takes a long time. In this work, we present data from a unique system of experimentally evolved laboratory populations of Drosophila melanogaster that have experienced three distinct life-history selection regimes. The goal of our study was to determine how quickly populations of a certain selection regime diverge phenotypically from their ancestors, and how quickly they converge with independently derived populations that share a selection regime. Our results indicate that phenotypic divergence from an ancestral population occurs rapidly, within dozens of generations, regardless of that population's evolutionary history. Similarly, populations sharing a selection treatment converge on common phenotypes in this same time frame, regardless of selection pressures those populations may have experienced in the past. These patterns of convergence and divergence emerged much faster than expected, suggesting that intermediate evolutionary history has transient effects in this system. The results we draw from this system are applicable to other experimental evolution projects, and suggest that many relevant questions can be sufficiently tested on shorter timescales than previously thought. © 2016 The Author(s). Evolution © 2016 The Society for the Study of Evolution.

  3. Health Insurance Instability Among Older Immigrants: Region of Origin Disparities in Coverage

    PubMed Central

    Hardy, Melissa

    2015-01-01

    Objectives. We provide a detailed analysis of how the dynamics of health insurance coverage (HIC) at older ages differs among Latino, Asian, and European immigrants in the United States. Method. Using Survey of Income and Program Participation data from the 2004 and 2008 panels, we estimate discrete-time event history models to examine first and second transitions into and out of HIC, highlighting substantial differences in hazard rates among immigrants aged 50–64 from Asia, Latin America, and Europe. Results. We find that the likelihood of having HIC at first observation and the rates of gaining and losing coverage within a relatively short time frame are least favorable for older Latino immigrants, although immigrants from all three regions are at a disadvantage relative to native-born non-Hispanic Whites. This disparity among immigrant groups persists even when lower rates of citizenship, greater difficulty with English, and low-skill job placements are taken into account. Discussion. Factors that have contributed to the lower rates and shorter durations of HIC among older immigrants, particularly those from Latin America, may not be easily resolved by the Affordable Care Act. The importance of region of origin and assimilation characteristics for the risk of being uninsured in later life argues that immigration and health care policy should be jointly addressed. PMID:25637934

  4. Galaxy Evolution Studies with the SPace IR Telescope for Cosmology and Astrophysics (SPICA): The Power of IR Spectroscopy

    NASA Astrophysics Data System (ADS)

    Spinoglio, L.; Alonso-Herrero, A.; Armus, L.; Baes, M.; Bernard-Salas, J.; Bianchi, S.; Bocchio, M.; Bolatto, A.; Bradford, C.; Braine, J.; Carrera, F. J.; Ciesla, L.; Clements, D. L.; Dannerbauer, H.; Doi, Y.; Efstathiou, A.; Egami, E.; Fernández-Ontiveros, J. A.; Ferrara, A.; Fischer, J.; Franceschini, A.; Gallerani, S.; Giard, M.; González-Alfonso, E.; Gruppioni, C.; Guillard, P.; Hatziminaoglou, E.; Imanishi, M.; Ishihara, D.; Isobe, N.; Kaneda, H.; Kawada, M.; Kohno, K.; Kwon, J.; Madden, S.; Malkan, M. A.; Marassi, S.; Matsuhara, H.; Matsuura, M.; Miniutti, G.; Nagamine, K.; Nagao, T.; Najarro, F.; Nakagawa, T.; Onaka, T.; Oyabu, S.; Pallottini, A.; Piro, L.; Pozzi, F.; Rodighiero, G.; Roelfsema, P.; Sakon, I.; Santini, P.; Schaerer, D.; Schneider, R.; Scott, D.; Serjeant, S.; Shibai, H.; Smith, J.-D. T.; Sobacchi, E.; Sturm, E.; Suzuki, T.; Vallini, L.; van der Tak, F.; Vignali, C.; Yamada, T.; Wada, T.; Wang, L.

    2017-11-01

    IR spectroscopy in the range 12-230 μm with the SPace IR telescope for Cosmology and Astrophysics (SPICA) will reveal the physical processes governing the formation and evolution of galaxies and black holes through cosmic time, bridging the gap between the James Webb Space Telescope and the upcoming Extremely Large Telescopes at shorter wavelengths and the Atacama Large Millimeter Array at longer wavelengths. The SPICA, with its 2.5-m telescope actively cooled to below 8 K, will obtain the first spectroscopic determination, in the mid-IR rest-frame, of both the star-formation rate and black hole accretion rate histories of galaxies, reaching lookback times of 12 Gyr, for large statistically significant samples. Densities, temperatures, radiation fields, and gas-phase metallicities will be measured in dust-obscured galaxies and active galactic nuclei, sampling a large range in mass and luminosity, from faint local dwarf galaxies to luminous quasars in the distant Universe. Active galactic nuclei and starburst feedback and feeding mechanisms in distant galaxies will be uncovered through detailed measurements of molecular and atomic line profiles. The SPICA's large-area deep spectrophotometric surveys will provide mid-IR spectra and continuum fluxes for unbiased samples of tens of thousands of galaxies, out to redshifts of z 6.

  5. NMR longitudinal relaxation enhancement in metal halides by heteronuclear polarization exchange during magic-angle spinning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shmyreva, Anna A.; Safdari, Majid; Furó, István

    2016-06-14

    Orders of magnitude decrease of {sup 207}Pb and {sup 199}Hg NMR longitudinal relaxation times T{sub 1} upon magic-angle-spinning (MAS) are observed and systematically investigated in solid lead and mercury halides MeX{sub 2} (Me = Pb, Hg and X = Cl, Br, I). In lead(II) halides, the most dramatic decrease of T{sub 1} relative to that in a static sample is in PbI{sub 2}, while it is smaller but still significant in PbBr{sub 2}, and not detectable in PbCl{sub 2}. The effect is magnetic-field dependent but independent of the spinning speed in the range 200–15 000 Hz. The observed relaxation enhancementmore » is explained by laboratory-frame heteronuclear polarization exchange due to crossing between energy levels of spin-1/2 metal nuclei and adjacent quadrupolar-spin halogen nuclei. The enhancement effect is also present in lead-containing organometal halide perovskites. Our results demonstrate that in affected samples, it is the relaxation data recorded under non-spinning conditions that characterize the local properties at the metal sites. A practical advantage of fast relaxation at slow MAS is that spectral shapes with orientational chemical shift anisotropy information well retained can be acquired within a shorter experimental time.« less

  6. 77 FR 7640 - Self-Regulatory Organizations; BATS Y-Exchange, Inc.; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-13

    ... 30 days after the date of the filing, or such shorter time as the Commission may designate, it has...-4(f)(6)(iii) \\8\\ permits the Commission to designate a shorter time if such action is consistent... without further delay. The Exchange notes that the introduction of the additional optional variation of...

  7. 77 FR 7642 - Self-Regulatory Organizations; BATS Exchange, Inc.; Notice of Filing and Immediate Effectiveness...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-13

    ... 30 days after the date of the filing, or such shorter time as the Commission may designate, it has...-4(f)(6)(iii) \\8\\ permits the Commission to designate a shorter time if such action is consistent... trading costs without further delay. The Exchange notes that the introduction of the additional optional...

  8. Drifty shifty deluxe.m

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Josh Sugar, Dave Robinson

    2014-01-24

    Performs a cross-correlation calculation to align images. This is particularly useful for aligning frames of a movie so that an object of interest does not spatially drift. For in situ microscopy experiments. Movies are collected where an object changes with time. At the same time, the object usually drifts too. This shifts the movie frames so that the object is aligned from frame to frame. Then it is easy to see the object changes without the added complication of it moving too.

  9. Echocardiogram video summarization

    NASA Astrophysics Data System (ADS)

    Ebadollahi, Shahram; Chang, Shih-Fu; Wu, Henry D.; Takoma, Shin

    2001-05-01

    This work aims at developing innovative algorithms and tools for summarizing echocardiogram videos. Specifically, we summarize the digital echocardiogram videos by temporally segmenting them into the constituent views and representing each view by the most informative frame. For the segmentation we take advantage of the well-defined spatio- temporal structure of the echocardiogram videos. Two different criteria are used: presence/absence of color and the shape of the region of interest (ROI) in each frame of the video. The change in the ROI is due to different modes of echocardiograms present in one study. The representative frame is defined to be the frame corresponding to the end- diastole of the heart cycle. To locate the end-diastole we track the ECG of each frame to find the exact time the time- marker on the ECG crosses the peak of the end-diastole we track the ECG of each frame to find the exact time the time- marker on the ECG crosses the peak of the R-wave. The corresponding frame is chosen to be the key-frame. The entire echocardiogram video can be summarized into either a static summary, which is a storyboard type of summary and a dynamic summary, which is a concatenation of the selected segments of the echocardiogram video. To the best of our knowledge, this if the first automated system for summarizing the echocardiogram videos base don visual content.

  10. [Dynamics of food transit in gastrectomized patients with and without dumping syndrome studied with the gamma camera and a marked meal].

    PubMed

    Palermo, F; Boccaletto, F; Allegri, F; Tommaseo, T; Chiara, G

    1988-01-01

    Scintigraphy was performed on a group of patients following the administration of a solid radiolabelled meal. As a tracer, human albumin microspheres were used with 99mTc, mixed with fresh scrambled eggs, eaten as a sandwich in two slices of white bread. The analysis of transit and emptying-rate of the radiolabelled meal in the gastric or derivative loop areas was performed by means of a medium field (300 mm) gamma camera interfaced with a digital computer; the data were collected at 15" frames for 90'-120'. Twenty-nine patients were examined who had undergone sub-total gastrectomy: 11 of them were "dumpers" and 18 "non-dumpers"; moreover, 9 volunteers without any history of gastrointestinal diseases and 11 patients with different gastric disorders were checked. In the first group of gastrectomized patients the half-emptying time (T50) was significantly shorter than in the 11 people being checked (Md = 27.5 +/- 10.8 versus 69.6 +/- 19 minutes); in "non-dumpers" T50 was even shorter (Md = 24.2 +/- 13 min). There was no significant statistical difference between the two classes of gastroresected patients in both T50 and emptying-rate of the radioactive solid food, which excludes the accelerated transit as a factor in the functional post-prandial symptoms of the dumping syndrome. On the contrary, the dynamic selective analysis of the radiolabelled food transit through derivative afferent and efferent loops showed different patterns in the two groups of gastroresected patients: the progression of the propulsive wave was very irregular and constantly hyperperistaltic only in the dumpers.

  11. Short-term mechanisms of toxic action of airborne particulates underlie dose-rate dependent health risks and support control of one-hour airborne particle levels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michaels, R.A.; Kleinman, M.T.

    1999-07-01

    Twenty-four-hour airborne particle mass levels permissible under the NAAQS have been associated with mortality and morbidity in communities, motivating reconsideration of the standard. Reports of shorter-term mechanisms of toxic action exerted by airborne PM and PM constituents are emerging. The mechanisms are diverse, but have in common a short time frame of toxic action, from minutes to hours. In view of documented PM excursions also lasting minutes to hours, this study inquires whether such short-term mechanisms might contribute to explaining daily morbidity and mortality. Toxicology experiments have demonstrated the harmfulness of brief exposure to PM levels in the range ofmore » observed excursions. This suggests that toxicological processes initiated by short-term inhalation of PM may exert clinically important effects, and that weak associations of 24-hour-average particle mass with mortality and morbidity may represent artifacts of stronger, shorter-term associations whose full magnitude remains to be quantified. In one study, the area of lung surface developing lesions was elevated in rats breathing the same four-hour dose of aerosols, when the four-hour average rate of aerosol delivery included a short-term (five-minute) burst fifty percent above the average dose rate. Elevations were observed with each of two aerosols tested. The magnitude of the effect was higher with one of the two aerosols, whose dose rate included four excursions rather than just one excursion. Particulate matter inhaled or instilled intratracheally has produced morbidity in animals, including apnea and electrophysiological effects in dogs. Other studies reveal that PM can kill rats via electrophysiological and possibly other mechanisms. PM has also adversely affected asthmatic people in controlled clinical settings during exercise or, in one study, at rest.« less

  12. Real time heart rate variability assessment from Android smartphone camera photoplethysmography: Postural and device influences.

    PubMed

    Guede-Fernandez, F; Ferrer-Mileo, V; Ramos-Castro, J; Fernandez-Chimeno, M; Garcia-Gonzalez, M A

    2015-01-01

    The aim of this paper is to present a smartphone based system for real-time pulse-to-pulse (PP) interval time series acquisition by frame-to-frame camera image processing. The developed smartphone application acquires image frames from built-in rear-camera at the maximum available rate (30 Hz) and the smartphone GPU has been used by Renderscript API for high performance frame-by-frame image acquisition and computing in order to obtain PPG signal and PP interval time series. The relative error of mean heart rate is negligible. In addition, measurement posture and the employed smartphone model influences on the beat-to-beat error measurement of heart rate and HRV indices have been analyzed. Then, the standard deviation of the beat-to-beat error (SDE) was 7.81 ± 3.81 ms in the worst case. Furthermore, in supine measurement posture, significant device influence on the SDE has been found and the SDE is lower with Samsung S5 than Motorola X. This study can be applied to analyze the reliability of different smartphone models for HRV assessment from real-time Android camera frames processing.

  13. A system for EPID-based real-time treatment delivery verification during dynamic IMRT treatment.

    PubMed

    Fuangrod, Todsaporn; Woodruff, Henry C; van Uytven, Eric; McCurdy, Boyd M C; Kuncic, Zdenka; O'Connor, Daryl J; Greer, Peter B

    2013-09-01

    To design and develop a real-time electronic portal imaging device (EPID)-based delivery verification system for dynamic intensity modulated radiation therapy (IMRT) which enables detection of gross treatment delivery errors before delivery of substantial radiation to the patient. The system utilizes a comprehensive physics-based model to generate a series of predicted transit EPID image frames as a reference dataset and compares these to measured EPID frames acquired during treatment. The two datasets are using MLC aperture comparison and cumulative signal checking techniques. The system operation in real-time was simulated offline using previously acquired images for 19 IMRT patient deliveries with both frame-by-frame comparison and cumulative frame comparison. Simulated error case studies were used to demonstrate the system sensitivity and performance. The accuracy of the synchronization method was shown to agree within two control points which corresponds to approximately ∼1% of the total MU to be delivered for dynamic IMRT. The system achieved mean real-time gamma results for frame-by-frame analysis of 86.6% and 89.0% for 3%, 3 mm and 4%, 4 mm criteria, respectively, and 97.9% and 98.6% for cumulative gamma analysis. The system can detect a 10% MU error using 3%, 3 mm criteria within approximately 10 s. The EPID-based real-time delivery verification system successfully detected simulated gross errors introduced into patient plan deliveries in near real-time (within 0.1 s). A real-time radiation delivery verification system for dynamic IMRT has been demonstrated that is designed to prevent major mistreatments in modern radiation therapy.

  14. Real-time CT-video registration for continuous endoscopic guidance

    NASA Astrophysics Data System (ADS)

    Merritt, Scott A.; Rai, Lav; Higgins, William E.

    2006-03-01

    Previous research has shown that CT-image-based guidance could be useful for the bronchoscopic assessment of lung cancer. This research drew upon the registration of bronchoscopic video images to CT-based endoluminal renderings of the airway tree. The proposed methods either were restricted to discrete single-frame registration, which took several seconds to complete, or required non-real-time buffering and processing of video sequences. We have devised a fast 2D/3D image registration method that performs single-frame CT-Video registration in under 1/15th of a second. This allows the method to be used for real-time registration at full video frame rates without significantly altering the physician's behavior. The method achieves its speed through a gradient-based optimization method that allows most of the computation to be performed off-line. During live registration, the optimization iteratively steps toward the locally optimal viewpoint at which a CT-based endoluminal view is most similar to a current bronchoscopic video frame. After an initial registration to begin the process (generally done in the trachea for bronchoscopy), subsequent registrations are performed in real-time on each incoming video frame. As each new bronchoscopic video frame becomes available, the current optimization is initialized using the previous frame's optimization result, allowing continuous guidance to proceed without manual re-initialization. Tests were performed using both synthetic and pre-recorded bronchoscopic video. The results show that the method is robust to initialization errors, that registration accuracy is high, and that continuous registration can proceed on real-time video at >15 frames per sec. with minimal user-intervention.

  15. Modeling laser-plasma acceleration in the laboratory frame

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2011-01-01

    A simulation of laser-plasma acceleration in the laboratory frame. Both the laser and the wakefield buckets must be resolved over the entire domain of the plasma, requiring many cells and many time steps. While researchers often use a simulation window that moves with the pulse, this reduces only the multitude of cells, not the multitude of time steps. For an artistic impression of how to solve the simulation by using the boosted-frame method, watch the video "Modeling laser-plasma acceleration in the wakefield frame".

  16. A new reference frame for astronomically-tuned Plio-Pleistocene climate variability derived from a benthic oxygen isotope splice of the Mediterranean

    NASA Astrophysics Data System (ADS)

    Lourens, L. J.; Ziegler, M.; Konijnendijk, T. Y. M.; Hilgen, F. J.; Bos, R.; Beekvelt, B.; van Loevezijn, A.; Collin, S.

    2017-12-01

    The astronomical theory of climate has revolutionized our understanding of past climate change and the development of highly accurate geologic time scales for the entire Cenozoic. Most of this understanding has come from the construction of astronomically tuned global ocean benthic foraminiferal oxygen isotope (δ18O) stacked record, derived by the international drilling operations of DSDP, ODP and IODP. The tuning includes fixed phase relationships between the obliquity and precession cycles and the inferred high-latitude climate, i.e. glacial-interglacial, response, which hark back to SPECMAP, using simple ice sheet models and a limited number of radiometric dates. This approach was largely implemented in the widely applied LR04 stack, though LR04 assumed shorter response times for the smaller ice caps during the Pliocene. In the past decades, an astronomically calibrated time scale for the Pliocene and Pleistocene of the Mediterranean has been developed, which has become the reference for the standard Geologic Time Scale. Typical of the Mediterranean marine sediments are the cyclic lithological alternations, reflecting the interference between obliquity and precession-paced low latitude climate variability, such as the African monsoon. Here we present the first benthic foraminiferal based oxygen isotope record of the Mediterranean reference scale, which strikingly mirrors the LR04. We will use this record to discuss the assumed open ocean glacial-interglacial related phase relations over the past 5.3 million years.

  17. Cloud Photogrammetry from Space

    NASA Astrophysics Data System (ADS)

    Zaksek, K.; Gerst, A.; von der Lieth, J.; Ganci, G.; Hort, M.

    2015-04-01

    The most commonly used method for satellite cloud top height (CTH) compares brightness temperature of the cloud with the atmospheric temperature profile. Because of the uncertainties of this method, we propose a photogrammetric approach. As clouds can move with high velocities, even instruments with multiple cameras are not appropriate for accurate CTH estimation. Here we present two solutions. The first is based on the parallax between data retrieved from geostationary (SEVIRI, HRV band; 1000 m spatial resolution) and polar orbiting satellites (MODIS, band 1; 250 m spatial resolution). The procedure works well if the data from both satellites are retrieved nearly simultaneously. However, MODIS does not retrieve the data at exactly the same time as SEVIRI. To compensate for advection in the atmosphere we use two sequential SEVIRI images (one before and one after the MODIS retrieval) and interpolate the cloud position from SEVIRI data to the time of MODIS retrieval. CTH is then estimated by intersection of corresponding lines-of-view from MODIS and interpolated SEVIRI data. The second method is based on NASA program Crew Earth observations from the International Space Station (ISS). The ISS has a lower orbit than most operational satellites, resulting in a shorter minimal time between two images, which is needed to produce a suitable parallax. In addition, images made by the ISS crew are taken by a full frame sensor and not a push broom scanner that most operational satellites use. Such data make it possible to observe also short time evolution of clouds.

  18. 77 FR 67409 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-09

    ...), 7410A (Definitions), 7420A (Applicability), 7430A (Synchronization of Member Business Clocks), 7440A... days after the date of the filing, or such shorter time as the Commission may designate if consistent... the proposed rule change, or such shorter time as designated by the Commission. \\11\\ 15 U.S.C. 78s(b...

  19. 42 CFR 62.73 - What are the procedures for participation in the Special Repayment Program?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... with the site to obtain employment at the site. (f) Effect of failure to meet established time frames... medical specialty for which the National Health service Corps has no need. (d) Time frames for matching... frames described in paragraph (d) of this section, the Secretary will determine that such individual is...

  20. A frame-critical policy analysis of Canada's response to the World Food Summit 1998-2008.

    PubMed

    Mah, Catherine L; Hamill, Catherine; Rondeau, Krista; McIntyre, Lynn

    2014-01-01

    The 2012 visit to Canada of Olivier De Schutter, the United Nations Special Rapporteur on the Right to Food, led to a public rebuff by Canadian governmental officials. This paper adapts the frame-critical policy analysis of Schön and Rein (1994), to explore the rhetorical basis for this conflict. This examination is offered as an illustrative example of how food insecurity is framed as a public policy problem in a high-income nation and how this framing has changed over time. We analyze Canada's decade of sequential responses to the 1996 World Food Summit, spanning 1998-2008, in the form of Canada's Action Plan on Food Security, and its subsequent Progress Reports. We conducted a qualitative policy analysis, adapting the frame-critical approach first delineated by Schön and Rein (1994). This analysis uses a social constructionist approach to map out the relationships between tacit understanding of policy by particular actors, explicit rhetoric in the public domain, and action in this policy area over time. We identify three key ways in which competing rhetorical frames arise over time: frame shifts (e.g., a shift away from language highlighting the right to food and health); frame blending (e.g., discussion about poverty becomes obscured by complexity discourse); and within-frame incongruence (e.g., monitoring for health indicators that are unrelated to policy solutions). Together, these frames illustrate how the conflict embodied in the UN Special Rapporteur's visit has been deeply woven into the policy discourse on food insecurity in Canada over time. Frame-critical analysis is instructive for exposing and also predicting tensions that impede forward progress on difficult policy issues. Accordingly, such analyses may be helpful in not only dissecting how policy can become 'stuck' in the process of change but in active reframing towards new policy solutions.

  1. Motion-Blur-Free High-Speed Video Shooting Using a Resonant Mirror

    PubMed Central

    Inoue, Michiaki; Gu, Qingyi; Takaki, Takeshi; Ishii, Idaku; Tajima, Kenji

    2017-01-01

    This study proposes a novel concept of actuator-driven frame-by-frame intermittent tracking for motion-blur-free video shooting of fast-moving objects. The camera frame and shutter timings are controlled for motion blur reduction in synchronization with a free-vibration-type actuator vibrating with a large amplitude at hundreds of hertz so that motion blur can be significantly reduced in free-viewpoint high-frame-rate video shooting for fast-moving objects by deriving the maximum performance of the actuator. We develop a prototype of a motion-blur-free video shooting system by implementing our frame-by-frame intermittent tracking algorithm on a high-speed video camera system with a resonant mirror vibrating at 750 Hz. It can capture 1024 × 1024 images of fast-moving objects at 750 fps with an exposure time of 0.33 ms without motion blur. Several experimental results for fast-moving objects verify that our proposed method can reduce image degradation from motion blur without decreasing the camera exposure time. PMID:29109385

  2. A polymorphism in a transporter of testosterone is a determinant of androgen independence in prostate cancer.

    PubMed

    Sharifi, Nima; Hamada, Akinobu; Sissung, Tristan; Danesi, Romano; Venzon, David; Baum, Caitlin; Gulley, James L; Price, Douglas K; Dahut, William L; Figg, William D

    2008-08-05

    To determine if patients with advanced prostate cancer carrying a polymorphism that codes for a more active testosterone transporter have less durable responses to androgen-deprivation therapy (ADT) than patients not carrying this polymorphism. We previously determined that a polymorphism in SLCO1B3 affects testosterone transport and that those men who have at least one wild-type T allele at the 334 T > G polymorphism in this gene have a shorter survival. We hypothesized that the T allele which increases testosterone transport would be associated with a shorter interval from ADT to androgen independence. We examined the association between this SLCO1B3 polymorphism and time from ADT to androgen independence, ADT to prostate-specific antigen (PSA) nadir and PSA nadir to androgen independence in 68 Caucasian patients with advanced prostate cancer who were treated with ADT with metastatic disease (D2) or biochemical failure with no metastatic disease (D0). When examined separately, patients in the individual stages tended to have a shorter time to androgen independence with the T allele in the D0 (P = 0.11) and D2 (P = 0.18) groups. Combining these groups and stratifying by stage yielded a statistically significant shorter time to androgen independence with the T allele (P = 0.048). A polymorphism in a transporter that increases testosterone import is associated with a shorter time to androgen independence in patients with prostate cancer who are treated with ADT.

  3. Time and outcome framing in intertemporal tradeoffs.

    PubMed

    Scholten, Marc; Read, Daniel

    2013-07-01

    A robust anomaly in intertemporal choice is the delay-speedup asymmetry: Receipts are discounted more, and payments are discounted less, when delayed than when expedited over the same interval. We developed 2 versions of the tradeoff model (Scholten & Read, 2010) to address such situations, in which an outcome is expected at a given time but then its timing is changed. The outcome framing model generalizes the approach taken by the hyperbolic discounting model (Loewenstein & Prelec, 1992): Not obtaining a positive outcome when expected is a worse than expected state, to which people are over-responsive, or hypersensitive, and not incurring a negative outcome when expected is a better than expected state, to which people are under-responsive, or hyposensitive. The time framing model takes a new approach: Delaying a positive outcome or speeding up a negative one involves a loss of time to which people are hypersensitive, and speeding up a positive outcome or delaying a negative one involves a gain of time to which people are hyposensitive. We compare the models on their quantitative predictions of indifference data from matching and preference data from choice. The time framing model systematically outperforms the outcome framing model. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  4. Between Accommodating and Activating: Framing Policy Reforms in Response to Workforce Aging across Europe.

    PubMed

    Kroon, Anne C; Vliegenthart, Rens; van Selm, Martine

    2017-07-01

    In the past decade, European governments have implemented activating policy reforms to maximize older workers' employment and employability, representing a paradigmatic change in approaches to work and retirement. This study isolates the factors that explain the relative success and failure of competitive frames that are either in favor of or against activating policies in European news coverage, by applying time-series analysis (ordinary least squares with panel-corrected standard errors) to monthly aggregated news coverage in the Netherlands, the United Kingdom, Denmark, and Spain over the timespan 2006-2013. The results show that pro-activating and counteractivating frames generally coincide in competitive framing environments. The pro-activating frame proliferated in times of high employment protection, whereas the counteractivating frame prevailed stronger in conservative compared with progressive newspapers, and gained momentum during the aftermath of the financial crisis and in times governments on the economic left were in power. The study advances knowledge of competitive issue framing by demonstrating how the economic, policy, and political context matters for the emergence and evolvement of competing frames. In addition, the findings contribute to the understanding of the factors that contribute to news representations that promote active aging in European news, which may foster support for policy reforms that sustain older workers' employability.

  5. Ultra-fast high-resolution hybrid and monolithic CMOS imagers in multi-frame radiography

    NASA Astrophysics Data System (ADS)

    Kwiatkowski, Kris; Douence, Vincent; Bai, Yibin; Nedrow, Paul; Mariam, Fesseha; Merrill, Frank; Morris, Christopher L.; Saunders, Andy

    2014-09-01

    A new burst-mode, 10-frame, hybrid Si-sensor/CMOS-ROIC FPA chip has been recently fabricated at Teledyne Imaging Sensors. The intended primary use of the sensor is in the multi-frame 800 MeV proton radiography at LANL. The basic part of the hybrid is a large (48×49 mm2) stitched CMOS chip of 1100×1100 pixel count, with a minimum shutter speed of 50 ns. The performance parameters of this chip are compared to the first generation 3-frame 0.5-Mpixel custom hybrid imager. The 3-frame cameras have been in continuous use for many years, in a variety of static and dynamic experiments at LANSCE. The cameras can operate with a per-frame adjustable integration time of ~ 120ns-to- 1s, and inter-frame time of 250ns to 2s. Given the 80 ms total readout time, the original and the new imagers can be externally synchronized to 0.1-to-5 Hz, 50-ns wide proton beam pulses, and record up to ~1000-frame radiographic movies typ. of 3-to-30 minute duration. The performance of the global electronic shutter is discussed and compared to that of a high-resolution commercial front-illuminated monolithic CMOS imager.

  6. Comparison between Frame-Constrained Fix-Pixel-Value and Frame-Free Spiking-Dynamic-Pixel ConvNets for Visual Processing

    PubMed Central

    Farabet, Clément; Paz, Rafael; Pérez-Carrasco, Jose; Zamarreño-Ramos, Carlos; Linares-Barranco, Alejandro; LeCun, Yann; Culurciello, Eugenio; Serrano-Gotarredona, Teresa; Linares-Barranco, Bernabe

    2012-01-01

    Most scene segmentation and categorization architectures for the extraction of features in images and patches make exhaustive use of 2D convolution operations for template matching, template search, and denoising. Convolutional Neural Networks (ConvNets) are one example of such architectures that can implement general-purpose bio-inspired vision systems. In standard digital computers 2D convolutions are usually expensive in terms of resource consumption and impose severe limitations for efficient real-time applications. Nevertheless, neuro-cortex inspired solutions, like dedicated Frame-Based or Frame-Free Spiking ConvNet Convolution Processors, are advancing real-time visual processing. These two approaches share the neural inspiration, but each of them solves the problem in different ways. Frame-Based ConvNets process frame by frame video information in a very robust and fast way that requires to use and share the available hardware resources (such as: multipliers, adders). Hardware resources are fixed- and time-multiplexed by fetching data in and out. Thus memory bandwidth and size is important for good performance. On the other hand, spike-based convolution processors are a frame-free alternative that is able to perform convolution of a spike-based source of visual information with very low latency, which makes ideal for very high-speed applications. However, hardware resources need to be available all the time and cannot be time-multiplexed. Thus, hardware should be modular, reconfigurable, and expansible. Hardware implementations in both VLSI custom integrated circuits (digital and analog) and FPGA have been already used to demonstrate the performance of these systems. In this paper we present a comparison study of these two neuro-inspired solutions. A brief description of both systems is presented and also discussions about their differences, pros and cons. PMID:22518097

  7. Comparison between Frame-Constrained Fix-Pixel-Value and Frame-Free Spiking-Dynamic-Pixel ConvNets for Visual Processing.

    PubMed

    Farabet, Clément; Paz, Rafael; Pérez-Carrasco, Jose; Zamarreño-Ramos, Carlos; Linares-Barranco, Alejandro; Lecun, Yann; Culurciello, Eugenio; Serrano-Gotarredona, Teresa; Linares-Barranco, Bernabe

    2012-01-01

    Most scene segmentation and categorization architectures for the extraction of features in images and patches make exhaustive use of 2D convolution operations for template matching, template search, and denoising. Convolutional Neural Networks (ConvNets) are one example of such architectures that can implement general-purpose bio-inspired vision systems. In standard digital computers 2D convolutions are usually expensive in terms of resource consumption and impose severe limitations for efficient real-time applications. Nevertheless, neuro-cortex inspired solutions, like dedicated Frame-Based or Frame-Free Spiking ConvNet Convolution Processors, are advancing real-time visual processing. These two approaches share the neural inspiration, but each of them solves the problem in different ways. Frame-Based ConvNets process frame by frame video information in a very robust and fast way that requires to use and share the available hardware resources (such as: multipliers, adders). Hardware resources are fixed- and time-multiplexed by fetching data in and out. Thus memory bandwidth and size is important for good performance. On the other hand, spike-based convolution processors are a frame-free alternative that is able to perform convolution of a spike-based source of visual information with very low latency, which makes ideal for very high-speed applications. However, hardware resources need to be available all the time and cannot be time-multiplexed. Thus, hardware should be modular, reconfigurable, and expansible. Hardware implementations in both VLSI custom integrated circuits (digital and analog) and FPGA have been already used to demonstrate the performance of these systems. In this paper we present a comparison study of these two neuro-inspired solutions. A brief description of both systems is presented and also discussions about their differences, pros and cons.

  8. Slow Speed--Fast Motion: Time-Lapse Recordings in Physics Education

    ERIC Educational Resources Information Center

    Vollmer, Michael; Möllmann, Klaus-Peter

    2018-01-01

    Video analysis with a 30 Hz frame rate is the standard tool in physics education. The development of affordable high-speed-cameras has extended the capabilities of the tool for much smaller time scales to the 1 ms range, using frame rates of typically up to 1000 frames s[superscript -1], allowing us to study transient physics phenomena happening…

  9. Time-series animation techniques for visualizing urban growth

    USGS Publications Warehouse

    Acevedo, W.; Masuoka, P.

    1997-01-01

    Time-series animation is a visually intuitive way to display urban growth. Animations of landuse change for the Baltimore-Washington region were generated by showing a series of images one after the other in sequential order. Before creating an animation, various issues which will affect the appearance of the animation should be considered, including the number of original data frames to use, the optimal animation display speed, the number of intermediate frames to create between the known frames, and the output media on which the animations will be displayed. To create new frames between the known years of data, the change in each theme (i.e. urban development, water bodies, transportation routes) must be characterized and an algorithm developed to create the in-between frames. Example time-series animations were created using a temporal GIS database of the Baltimore-Washington area. Creating the animations involved generating raster images of the urban development, water bodies, and principal transportation routes; overlaying the raster images on a background image; and importing the frames to a movie file. Three-dimensional perspective animations were created by draping each image over digital elevation data prior to importing the frames to a movie file. ?? 1997 Elsevier Science Ltd.

  10. Molecular Frame Reconstruction Using Time-Domain Photoionization Interferometry.

    PubMed

    Marceau, Claude; Makhija, Varun; Platzer, Dominique; Naumov, A Yu; Corkum, P B; Stolow, Albert; Villeneuve, D M; Hockett, Paul

    2017-08-25

    Photoionization of molecular species is, essentially, a multipath interferometer with both experimentally controllable and intrinsic molecular characteristics. In this work, XUV photoionization of impulsively aligned molecular targets (N_{2}) is used to provide a time-domain route to "complete" photoionization experiments, in which the rotational wave packet controls the geometric part of the photoionization interferometer. The data obtained is sufficient to determine the magnitudes and phases of the ionization matrix elements for all observed channels, and to reconstruct molecular frame interferograms from lab frame measurements. In principle, this methodology provides a time-domain route to complete photoionization experiments and the molecular frame, which is generally applicable to any molecule (no prerequisites), for all energies and ionization channels.

  11. Enhancement of dynamic myocardial perfusion PET images based on low-rank plus sparse decomposition.

    PubMed

    Lu, Lijun; Ma, Xiaomian; Mohy-Ud-Din, Hassan; Ma, Jianhua; Feng, Qianjin; Rahmim, Arman; Chen, Wufan

    2018-02-01

    The absolute quantification of dynamic myocardial perfusion (MP) PET imaging is challenged by the limited spatial resolution of individual frame images due to division of the data into shorter frames. This study aims to develop a method for restoration and enhancement of dynamic PET images. We propose that the image restoration model should be based on multiple constraints rather than a single constraint, given the fact that the image characteristic is hardly described by a single constraint alone. At the same time, it may be possible, but not optimal, to regularize the image with multiple constraints simultaneously. Fortunately, MP PET images can be decomposed into a superposition of background vs. dynamic components via low-rank plus sparse (L + S) decomposition. Thus, we propose an L + S decomposition based MP PET image restoration model and express it as a convex optimization problem. An iterative soft thresholding algorithm was developed to solve the problem. Using realistic dynamic 82 Rb MP PET scan data, we optimized and compared its performance with other restoration methods. The proposed method resulted in substantial visual as well as quantitative accuracy improvements in terms of noise versus bias performance, as demonstrated in extensive 82 Rb MP PET simulations. In particular, the myocardium defect in the MP PET images had improved visual as well as contrast versus noise tradeoff. The proposed algorithm was also applied on an 8-min clinical cardiac 82 Rb MP PET study performed on the GE Discovery PET/CT, and demonstrated improved quantitative accuracy (CNR and SNR) compared to other algorithms. The proposed method is effective for restoration and enhancement of dynamic PET images. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. TURBULENCE IN THE SOLAR WIND MEASURED WITH COMET TAIL TEST PARTICLES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeForest, C. E.; Howard, T. A.; Matthaeus, W. H.

    2015-10-20

    By analyzing the motions of test particles observed remotely in the tail of Comet Encke, we demonstrate that the solar wind undergoes turbulent processing enroute from the Sun to the Earth and that the kinetic energy entrained in the large-scale turbulence is sufficient to explain the well-known anomalous heating of the solar wind. Using the heliospheric imaging (HI-1) camera on board NASA's STEREO-A spacecraft, we have observed an ensemble of compact features in the comet tail as they became entrained in the solar wind near 0.4 AU. We find that the features are useful as test particles, via mean-motion analysismore » and a forward model of pickup dynamics. Using population analysis of the ensemble's relative motion, we find a regime of random-walk diffusion in the solar wind, followed, on larger scales, by a surprising regime of semiconfinement that we attribute to turbulent eddies in the solar wind. The entrained kinetic energy of the turbulent motions represents a sufficient energy reservoir to heat the solar wind to observed temperatures at 1 AU. We determine the Lagrangian-frame diffusion coefficient in the diffusive regime, derive upper limits for the small scale coherence length of solar wind turbulence, compare our results to existing Eulerian-frame measurements, and compare the turbulent velocity with the size of the observed eddies extrapolated to 1 AU. We conclude that the slow solar wind is fully mixed by turbulence on scales corresponding to a 1–2 hr crossing time at Earth; and that solar wind variability on timescales shorter than 1–2 hr is therefore dominated by turbulent processing rather than by direct solar effects.« less

  13. Internet video telephony allows speech reading by deaf individuals and improves speech perception by cochlear implant users.

    PubMed

    Mantokoudis, Georgios; Dähler, Claudia; Dubach, Patrick; Kompis, Martin; Caversaccio, Marco D; Senn, Pascal

    2013-01-01

    To analyze speech reading through Internet video calls by profoundly hearing-impaired individuals and cochlear implant (CI) users. Speech reading skills of 14 deaf adults and 21 CI users were assessed using the Hochmair Schulz Moser (HSM) sentence test. We presented video simulations using different video resolutions (1280 × 720, 640 × 480, 320 × 240, 160 × 120 px), frame rates (30, 20, 10, 7, 5 frames per second (fps)), speech velocities (three different speakers), webcameras (Logitech Pro9000, C600 and C500) and image/sound delays (0-500 ms). All video simulations were presented with and without sound and in two screen sizes. Additionally, scores for live Skype™ video connection and live face-to-face communication were assessed. Higher frame rate (>7 fps), higher camera resolution (>640 × 480 px) and shorter picture/sound delay (<100 ms) were associated with increased speech perception scores. Scores were strongly dependent on the speaker but were not influenced by physical properties of the camera optics or the full screen mode. There is a significant median gain of +8.5%pts (p = 0.009) in speech perception for all 21 CI-users if visual cues are additionally shown. CI users with poor open set speech perception scores (n = 11) showed the greatest benefit under combined audio-visual presentation (median speech perception +11.8%pts, p = 0.032). Webcameras have the potential to improve telecommunication of hearing-impaired individuals.

  14. Design and Principles Enabling the Space Reference FOM

    NASA Technical Reports Server (NTRS)

    Moeller, Bjoern; Dexter, Dan; Madden, Michael; Crues, Edwin Z.; Garro, Alfredo; Skuratovskiy, Anton

    2017-01-01

    A first complete draft of the Simulation Interoperability Standards Organization (SISO) Space Reference Federation Object Model (FOM) has now been produced. This paper provides some insights into its capabilities and discusses the opportunity for reuse in other domains. The focus of this first version of the standard is execution control, time management and coordinate systems, well-known reference frames, as well as some basic support for physical entities. The biggest part of the execution control is the coordinated start-up process. This process contains a number of steps, including checking of required federates, handling of early versus late joiners, sharing of federation wide configuration data and multi-phase initialization. An additional part of Execution Control is the coordinated and synchronized transition between Run mode, Freeze mode and Shutdown. For time management, several time lines are defined, including real-time, scenario time, High Level Architecture (HLA) logical time and physical time. A strategy for mixing simulations that use different time steps is introduced, as well as an approach for finding common boundaries for fully synchronized freeze. For describing spatial information, a mechanism with a set of reference frames is specified. Each reference frame has a position and orientation related to a parent reference frame. This makes it possible for federates to perform calculations in reference frames that are convenient to them. An operation on the Moon can be performed using lunar coordinates whereas an operation on Earth can be performed using Earth coordinates. At the same time, coordinates in one reference frame have an unambiguous relationship to a coordinate in another reference frame. While the Space Reference FOM is originally being developed for Space operations, the authors believe that many parts of it can be reused for any simulation that has a focus on physical processes with one or more coordinate systems, and require high fidelity and repeatability.

  15. Telemetry Standards, Part 1

    DTIC Science & Technology

    2015-07-01

    IMAGE FRAME RATE (R-x\\ IFR -n) PRE-TRIGGER FRAMES (R-x\\PTG-n) TOTAL FRAMES (R-x\\TOTF-n) EXPOSURE TIME (R-x\\EXP-n) SENSOR ROTATION (R-x...0” (Single frame). “1” (Multi-frame). “2” (Continuous). Allowed when: When R\\CDT is “IMGIN” IMAGE FRAME RATE R-x\\ IFR -n R/R Ch 10 Status: RO...the settings that the user wishes to modify. Return Value The impact : A partial IHAL <configuration> element containing only the new settings for

  16. Living Color Frame System: PC graphics tool for data visualization

    NASA Technical Reports Server (NTRS)

    Truong, Long V.

    1993-01-01

    Living Color Frame System (LCFS) is a personal computer software tool for generating real-time graphics applications. It is highly applicable for a wide range of data visualization in virtual environment applications. Engineers often use computer graphics to enhance the interpretation of data under observation. These graphics become more complicated when 'run time' animations are required, such as found in many typical modern artificial intelligence and expert systems. Living Color Frame System solves many of these real-time graphics problems.

  17. Discrimination in waiting times by insurance type and financial soundness of German acute care hospitals.

    PubMed

    Schwierz, Christoph; Wübker, Achim; Wübker, Ansgar; Kuchinke, Björn A

    2011-10-01

    This paper shows that patients with private health insurance (PHI) are being offered significantly shorter waiting times than patients with statutory health insurance (SHI) in German acute hospital care. This behavior may be driven by the higher expected profitability of PHI relative to SHI holders. Further, we find that hospitals offering private insurees shorter waiting times when compared with SHI holders have a significantly better financial performance than those abstaining from or with less discrimination.

  18. Automatic detection of end-diastolic and end-systolic frames in 2D echocardiography.

    PubMed

    Zolgharni, Massoud; Negoita, Madalina; Dhutia, Niti M; Mielewczik, Michael; Manoharan, Karikaran; Sohaib, S M Afzal; Finegold, Judith A; Sacchi, Stefania; Cole, Graham D; Francis, Darrel P

    2017-07-01

    Correctly selecting the end-diastolic and end-systolic frames on a 2D echocardiogram is important and challenging, for both human experts and automated algorithms. Manual selection is time-consuming and subject to uncertainty, and may affect the results obtained, especially for advanced measurements such as myocardial strain. We developed and evaluated algorithms which can automatically extract global and regional cardiac velocity, and identify end-diastolic and end-systolic frames. We acquired apical four-chamber 2D echocardiographic video recordings, each at least 10 heartbeats long, acquired twice at frame rates of 52 and 79 frames/s from 19 patients, yielding 38 recordings. Five experienced echocardiographers independently marked end-systolic and end-diastolic frames for the first 10 heartbeats of each recording. The automated algorithm also did this. Using the average of time points identified by five human operators as the reference gold standard, the individual operators had a root mean square difference from that gold standard of 46.5 ms. The algorithm had a root mean square difference from the human gold standard of 40.5 ms (P<.0001). Put another way, the algorithm-identified time point was an outlier in 122/564 heartbeats (21.6%), whereas the average human operator was an outlier in 254/564 heartbeats (45%). An automated algorithm can identify the end-systolic and end-diastolic frames with performance indistinguishable from that of human experts. This saves staff time, which could therefore be invested in assessing more beats, and reduces uncertainty about the reliability of the choice of frame. © 2017, Wiley Periodicals, Inc.

  19. A characterization of persistence at short times in the WFC3/IR detector

    NASA Astrophysics Data System (ADS)

    Gennaro, M.; Bajaj, V.; Long, K.

    2018-05-01

    Persistence in the WFC3/IR detector appears to decay as a power law as a function of time elapsed since the end of a stimulus. In this report we study departures from the power law at times shorter than a few hundreds seconds after the stimulus. In order to have better short-time cadence, we use the Multiaccum (.ima) files, which trace the accumulated charge in the pixels as function of time, rather than the final pipeline products (.flt files), which instead report the electron rate estimated via a linear fit to the accumulated charge vs. time relation. We note that at short times after the stimulus, the absolute change in persistence is the strongest, thus a linear fit to the accumulated signal (the .flt values) can be a poor representation of the strongly varying persistence signal. The already observed power-law decay of the persistence signal, still holds at shorter times, with typical values of the power law index, gamma in [-0.8,-1] for stimuli that saturate the WFC3 pixels. To a good degree of approximation, a single power law is a good fit to the persistence signal decay from 100 to 5000 seconds. We also detect a tapering-off in the power-law decay at increasingly shorter times. This change in behavior is of the order of Delta Gamma 0.02 - 0.05 when comparing power-law fits performed to the persistence signal from 0 up to 250 seconds and from 0 up to 4000 seconds after the stimulus, indicating that persistence decays slightly more rapidly as time progresses. Our results may suggest that for even shorter times, not probed by our study, the WFC3 persistence signal might deviate from a single power-law model.

  20. Support time-dependent transformations for surveying and GIS : current status and upcoming challenges

    NASA Astrophysics Data System (ADS)

    Mahmoudabadi, H.; Lercier, D.; Vielliard, S.; Mein, N.; Briggs, G.

    2016-12-01

    The support of time-dependent transformations for surveying and GIS is becoming a critical issue. We need to convert positions from the realizations of the International Terrestrial Reference Frame to any national reference frame. This problem is easy to solve when all of the required information is available. But it becomes really complicated in a worldwide context. We propose an overview of the current ITRF-aligned reference frames and we describe a global solution to support time-dependent transformations between them and the International Terrestrial Reference Frame. We focus on the uncertainties of station velocities used. In a first approximation, we use a global tectonic plate model to calculate point velocities. We show the impact of the velocity model on the coordinate accuracies. Several countries, particularly in active regions, are developing semi-dynamic reference frames. These frames include local displacement models updated regularly and/or after major events (such as earthquakes). Their integration into surveying or GIS applications is an upcoming challenge. We want to encourage the geodetic community to develop and use standard formats.

  1. [A comparison of laparoscopic versus open repair for the surgical treatment of perforated peptic ulcers].

    PubMed

    Domínguez-Vega, Gerardo; Pera, Manuel; Ramón, José M; Puig, Sonia; Membrilla, Estela; Sancho, Joan; Grande, Luis

    2013-01-01

    To analyse the outcomes of laparoscopic versus open repair for perforated peptic ulcers (PPU). All patients undergoing PPU repair between January 2002 and March 2012 were included in the study. Demographic characteristics, operation time, complications, and length of hospital stay were evaluated. Two hundred and twelve patients (median age, 49 years) were included, 60 in the laparoscopic group and 52 in the open group. Patients operated laparoscopically were significantly younger and had a higher consumption of tobacco, alcohol and cannabis. Median acute symptoms time was shorter in the laparoscopic group (6h) compared to the open group (12h; P=.025) Symptoms time was shorter in the laparoscopic group. Median operating time was significantly longer in the laparoscopic group (104.5min vs. 76min, P=.025). The percentage of conversion to open repair was 25%. There was no difference in morbidity between 2 groups, but there were 3 deaths in the open group. Median hospital stay was significantly shorter in patients treated laparoscopically when compared with the open group (6 days vs. 8 days; P=.041). Laparoscopic and open repair are equally safe in the management of PPU. A shorter hospital stay can be achieved in the laparoscopic group. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.

  2. Automating Frame Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanfilippo, Antonio P.; Franklin, Lyndsey; Tratz, Stephen C.

    2008-04-01

    Frame Analysis has come to play an increasingly stronger role in the study of social movements in Sociology and Political Science. While significant steps have been made in providing a theory of frames and framing, a systematic characterization of the frame concept is still largely lacking and there are no rec-ognized criteria and methods that can be used to identify and marshal frame evi-dence reliably and in a time and cost effective manner. Consequently, current Frame Analysis work is still too reliant on manual annotation and subjective inter-pretation. The goal of this paper is to present an approach to themore » representation, acquisition and analysis of frame evidence which leverages Content Analysis, In-formation Extraction and Semantic Search methods to provide a systematic treat-ment of a Frame Analysis and automate frame annotation.« less

  3. SU-G-BRA-02: Development of a Learning Based Block Matching Algorithm for Ultrasound Tracking in Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shepard, A; Bednarz, B

    Purpose: To develop an ultrasound learning-based tracking algorithm with the potential to provide real-time motion traces of anatomy-based fiducials that may aid in the effective delivery of external beam radiation. Methods: The algorithm was developed in Matlab R2015a and consists of two main stages: reference frame selection, and localized block matching. Immediately following frame acquisition, a normalized cross-correlation (NCC) similarity metric is used to determine a reference frame most similar to the current frame from a series of training set images that were acquired during a pretreatment scan. Segmented features in the reference frame provide the basis for the localizedmore » block matching to determine the feature locations in the current frame. The boundary points of the reference frame segmentation are used as the initial locations for the block matching and NCC is used to find the most similar block in the current frame. The best matched block locations in the current frame comprise the updated feature boundary. The algorithm was tested using five features from two sets of ultrasound patient data obtained from MICCAI 2014 CLUST. Due to the lack of a training set associated with the image sequences, the first 200 frames of the image sets were considered a valid training set for preliminary testing, and tracking was performed over the remaining frames. Results: Tracking of the five vessel features resulted in an average tracking error of 1.21 mm relative to predefined annotations. The average analysis rate was 15.7 FPS with analysis for one of the two patients reaching real-time speeds. Computations were performed on an i5-3230M at 2.60 GHz. Conclusion: Preliminary tests show tracking errors comparable with similar algorithms at close to real-time speeds. Extension of the work onto a GPU platform has the potential to achieve real-time performance, making tracking for therapy applications a feasible option. This work is partially funded by NIH grant R01CA190298.« less

  4. The limited role of recombination energy in common envelope removal

    NASA Astrophysics Data System (ADS)

    Grichener, Aldana; Sabach, Efrat; Soker, Noam

    2018-05-01

    We calculate the outward energy transport time by convection and photon diffusion in an inflated common envelope and find this time to be shorter than the envelope expansion time. We conclude therefore that most of the hydrogen recombination energy ends in radiation rather than in kinetic energy of the outflowing envelope. We use the stellar evolution code MESA and inject energy inside the envelope of an asymptotic giant branch star to mimic energy deposition by a spiraling-in stellar companion. During 1.7 years the envelope expands by a factor of more than 2. Along the entire evolution the convection can carry the energy very efficiently outwards, to the radius where radiative transfer becomes more efficient. The total energy transport time stays within several months, shorter than the dynamical time of the envelope. Had we included rapid mass loss, as is expected in the common envelope evolution, the energy transport time would have been even shorter. It seems that calculations that assume that most of the recombination energy ends in the outflowing gas might be inaccurate.

  5. Inclusion of mobile telephone numbers into an ongoing population health survey in New South Wales, Australia, using an overlapping dual-frame design: impact on the time series.

    PubMed

    Barr, Margo L; Ferguson, Raymond A; Steel, David G

    2014-08-12

    Since 1997, the NSW Population Health Survey (NSWPHS) had selected the sample using random digit dialing of landline telephone numbers. When the survey began coverage of the population by landline phone frames was high (96%). As landline coverage in Australia has declined and continues to do so, in 2012, a sample of mobile telephone numbers was added to the survey using an overlapping dual-frame design. Details of the methodology are published elsewhere. This paper discusses the impacts of the sampling frame change on the time series, and provides possible approaches to handling these impacts. Prevalence estimates were calculated for type of phone-use, and a range of health indicators. Prevalence ratios (PR) for each of the health indicators were also calculated using Poisson regression analysis with robust variance estimation by type of phone-use. Health estimates for 2012 were compared to 2011. The full time series was examined for selected health indicators. It was estimated from the 2012 NSWPHS that 20.0% of the NSW population were mobile-only phone users. Looking at the full time series for overweight or obese and current smoking if the NSWPHS had continued to be undertaken only using a landline frame, overweight or obese would have been shown to continue to increase and current smoking would have been shown to continue to decrease. However, with the introduction of the overlapping dual-frame design in 2012, overweight or obese increased until 2011 and then decreased in 2012, and current smoking decreased until 2011, and then increased in 2012. Our examination of these time series showed that the changes were a consequence of the sampling frame change and were not real changes. Both the backcasting method and the minimal coverage method could adequately adjust for the design change and allow for the continuation of the time series. The inclusion of the mobile telephone numbers, through an overlapping dual-frame design, did impact on the time series for some of the health indicators collected through the NSWPHS, but only in that it corrected the estimates that were being calculated from a sample frame that was progressively covering less of the population.

  6. Media framing and construction of childhood obesity: a content analysis of Swedish newspapers.

    PubMed

    van Hooft, J; Patterson, C; Löf, M; Alexandrou, C; Hilton, S; Nimegeer, A

    2018-02-01

    Despite lower prevalence than most European countries, childhood obesity is a Swedish public health priority due to its lasting health impacts and socioeconomic patterning. Mass media content influences public and political perceptions of health issues, and media framing of childhood obesity may influence perceptions of its solutions. This study examines framing of childhood obesity in Swedish morning and evening newspapers from 1996 to 2014. Content analysis of 726 articles about childhood obesity published in the five most-circulated Swedish newspapers. Article content coded quantitatively and subjected to statistical analysis, describing relationships between themes and trends over time. Childhood obesity was consistently problematised, primarily in health terms, and linked to socio-economic and geographical factors. The yearly frequency of articles peaked in 2004, followed by a decline, corresponding with evidence about prevalence. Childhood obesity was framed as being driven by individual behaviours more frequently than structural or environmental factors. Structural framings increased over time, but constructions of the problem as driven by individual behaviours, particularly parenting, remained prominent. A relative growth in structural framings of causes and solutions over time, combined with prominent coverage of socio-economic inequalities, might be indicative of public and political amenability towards societal-level solutions, but individual behaviours remain prominent in framing of the issue. Health advocates might incorporate these insights into media engagement.

  7. CaMKIIalpha 3' untranslated region-directed mRNA translocation in living neurons: visualization by GFP linkage

    NASA Technical Reports Server (NTRS)

    Rook, M. S.; Lu, M.; Kosik, K. S.

    2000-01-01

    The CaMKIIalpha mRNA extends into distal hippocampal dendrites, and the 3' untranslated region (3'UTR) is sufficient to mediate this localization. We labeled the 3'UTR of the CaMKIIalpha mRNA in hippocampal cultures by using a green fluorescent protein (GFP)/MS2 bacteriophage tagging system. The CaMKIIalpha 3'UTR formed discrete granules throughout the dendrites of transfected cells. The identity of the fluorescent granules was verified by in situ hybridization. Over 30 min time periods these granules redistributed without a net increase in granule number; with depolarization there is a tendency toward increased numbers of granules in the dendrites. These observations suggest that finer time resolution of granule motility might reveal changes in the motility characteristics of granules after depolarization. So that motile granules could be tracked, shorter periods of observation were required. The movements of motile granules can be categorized as oscillatory, unidirectional anterograde, or unidirectional retrograde. Colocalization of CaMKIIalpha 3'UTR granules and synapses suggested that oscillatory movements allowed the granules to sample several local synapses. Neuronal depolarization increased the number of granules in the anterograde motile pool. Based on the time frame over which the granule number increased, the translocation of granules may serve to prepare the dendrite for mounting an adequate local translation response to future stimuli. Although the resident pool of granules can respond to signals that induce local translation, the number of granules in a dendrite might reflect its activation history.

  8. A candidate secular variation model for IGRF-12 based on Swarm data and inverse geodynamo modelling

    NASA Astrophysics Data System (ADS)

    Fournier, Alexandre; Aubert, Julien; Thébault, Erwan

    2015-05-01

    In the context of the 12th release of the international geomagnetic reference field (IGRF), we present the methodology we followed to design a candidate secular variation model for years 2015-2020. An initial geomagnetic field model centered around 2014.3 is first constructed, based on Swarm magnetic measurements, for both the main field and its instantaneous secular variation. This initial model is next fed to an inverse geodynamo modelling framework in order to specify, for epoch 2014.3, the initial condition for the integration of a three-dimensional numerical dynamo model. The initialization phase combines the information contained in the initial model with that coming from the numerical dynamo model, in the form of three-dimensional multivariate statistics built from a numerical dynamo run unconstrained by data. We study the performance of this novel approach over two recent 5-year long intervals, 2005-2010 and 2009-2014. For a forecast horizon of 5 years, shorter than the large-scale secular acceleration time scale (˜10 years), we find that it is safer to neglect the flow acceleration and to assume that the flow determined by the initialization is steady. This steady flow is used to advance the three-dimensional induction equation forward in time, with the benefit of estimating the effects of magnetic diffusion. The result of this deterministic integration between 2015.0 and 2020.0 yields our candidate average secular variation model for that time frame, which is thus centered on 2017.5.

  9. A comparison between findings from the DREEM questionnaire and that from qualitative interviews.

    PubMed

    Denz-Penhey, Harriet; Murdoch, J Campbell

    2009-10-01

    The Rural Clinical School of Western Australia educates one quarter of all Western Australian medical students in their first clinical year in rural settings. As part of a comprehensive evaluation programme students give feedback regularly. To identify if the Dundee Ready Education Environment Measurement (DREEM) data could be used qualitatively and descriptively to determine specific problems from the data alone despite the small numbers at some sites. The DREEM questionnaire was administered on the same day as qualitative interviews were undertaken. The qualitative interviews were analysed thematically first and then compared with findings from DREEM. Each major (student related) evaluation issue identified by the qualitative interviews was also identified by the DREEM questionnaire analysis. When the DREEM study was undertaken in the Rural Clinical School of Western Australia there was no real expectation that it would provide sufficient information to identify issues picked up in the extensive and time consuming qualitative study. About half of the work undertaken by the qualitative evaluation, that of the experiences of the students at the site, was picked up by the DREEM questionnaire in a much shorter time frame and at less cost of staff time and resources. The DREEM questionnaire can be used qualitatively to assess very specific issues relating to each of the subscales. These findings extend the use of DREEM from quantitative and statistically significant research to qualitative meaning-filled interpretations. The issues then need to be addressed sensitively.

  10. 75 FR 22109 - Aluminum Extrusions from the People's Republic of China: Initiation of Antidumping Duty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-27

    ... frames, door frames, solar panels, curtain walls, or furniture. Such parts that otherwise meet the... the time of entry, such as finished windows with glass, doors, picture frames, and solar panels. The...

  11. Development of two-framing camera with large format and ultrahigh speed

    NASA Astrophysics Data System (ADS)

    Jiang, Xiaoguo; Wang, Yuan; Wang, Yi

    2012-10-01

    High-speed imaging facility is important and necessary for the formation of time-resolved measurement system with multi-framing capability. The framing camera which satisfies the demands of both high speed and large format needs to be specially developed in the ultrahigh speed research field. A two-framing camera system with high sensitivity and time-resolution has been developed and used for the diagnosis of electron beam parameters of Dragon-I linear induction accelerator (LIA). The camera system, which adopts the principle of light beam splitting in the image space behind the lens with long focus length, mainly consists of lens-coupled gated image intensifier, CCD camera and high-speed shutter trigger device based on the programmable integrated circuit. The fastest gating time is about 3 ns, and the interval time between the two frames can be adjusted discretely at the step of 0.5 ns. Both the gating time and the interval time can be tuned to the maximum value of about 1 s independently. Two images with the size of 1024×1024 for each can be captured simultaneously in our developed camera. Besides, this camera system possesses a good linearity, uniform spatial response and an equivalent background illumination as low as 5 electrons/pix/sec, which fully meets the measurement requirements of Dragon-I LIA.

  12. Post-Newtonian Reference Frames for Advanced Theory of the Lunar Motion and a New Generation of Lunar Laser Ranging

    NASA Astrophysics Data System (ADS)

    Xie, Yi; Kopeikin, Sergei Affiliaiton: AB(Department of Physics and Astronomy, University of Missouri, USA kopeikins@missouri.edu)

    2010-08-01

    We overview a set of post-Newtonian reference frames for a comprehensive study of the orbital dynamics and rotational motion of Moon and Earth by means of lunar laser ranging (LLR). We employ a scalar-tensor theory of gravity depending on two post-Newtonian parameters, and , and utilize the relativistic resolutions on reference frames adopted by the International Astronomical Union (IAU) in 2000. We assume that the solar system is isolated and space-time is asymptotically flat at infinity. The primary reference frame covers the entire space-time, has its origin at the solar-system barycenter (SSB) and spatial axes stretching up to infinity. The SSB frame is not rotating with respect to a set of distant quasars that are forming the International Celestial Reference Frame (ICRF). The secondary reference frame has its origin at the Earth-Moon barycenter (EMB). The EMB frame is locally-inertial and is not rotating dynamically in the sense that equation of motion of a test particle moving with respect to the EMB frame, does not contain the Coriolis and centripetal forces. Two other local frames geocentric (GRF) and selenocentric (SRF) have their origins at the center of mass of Earth and Moon respectively and do not rotate dynamically. Each local frame is subject to the geodetic precession both with respect to other local frames and with respect to the ICRF because of their relative motion with respect to each other. Theoretical advantage of the dynamically non-rotating local frames is in a more simple mathematical description. Each local frame can be aligned with the axes of ICRF after applying the matrix of the relativistic precession. The set of one global and three local frames is introduced in order to fully decouple the relative motion of Moon with respect to Earth from the orbital motion of the Earth-Moon barycenter as well as to connect the coordinate description of the lunar motion, an observer on Earth, and a retro-reflector on Moon to directly measurable quantities such as the proper time and the round-trip laser-light distance. We solve the gravity field equations and find out the metric tensor and the scalar field in all frames which description includes the post-Newtonian multipole moments of the gravitational field of Earth and Moon. We also derive the post-Newtonian coordinate transformations between the frames and analyze the residual gauge freedom.

  13. Relationship Between Final Performance and Block Times with the Traditional and the New Starting Platforms with A Back Plate in International Swimming Championship 50-M and 100-M Freestyle Events

    PubMed Central

    Garcia-Hermoso, Antonio; Escalante, Yolanda; Arellano, Raul; Navarro, Fernando; Domínguez, Ana M.; Saavedra, Jose M.

    2013-01-01

    The purpose of this study was to investigate the association between block time and final performance for each sex in 50-m and 100-m individual freestyle, distinguishing between classification (1st to 3rd, 4th to 8th, 9th to 16th) and type of starting platform (old and new) in international competitions. Twenty-six international competitions covering a 13-year period (2000-2012) were analysed retrospectively. The data corresponded to a total of 1657 swimmers’ competition histories. A two-way ANOVA (sex x classification) was performed for each event and starting platform with the Bonferroni post-hoc test, and another two-way ANOVA for sex and starting platform (sex x starting platform). Pearson’s simple correlation coefficient was used to determine correlations between the block time and the final performance. Finally, a simple linear regression analysis was done between the final time and the block time for each sex and platform. The men had shorter starting block times than the women in both events and from both platforms. For 50-m event, medalists had shorter block times than semi- finalists with the old starting platforms. Block times were directly related to performance with the old starting platforms. With the new starting platforms, however, the relationship was inverse, notably in the women’s 50-m event. The block time was related for final performance in the men’s 50- m event with the old starting platform, but with the new platform it was critical only for the women’s 50-m event. Key Points The men had shorter block times than the women in both events and with both platforms. For both distances, the swimmers had shorter block times in their starts from the new starting platform with a back plate than with the old platform. For the 50-m event with the old starting platform, the medalists had shorter block times than the semi-finalists. The new starting platform block time was only determinant in the women’s 50-m event. In order to improve performance, specific training with the new platform with a back plate should be considered. PMID:24421729

  14. Potential sulfur-free pulping methods

    Treesearch

    Edward L. Springer; Rajai H. Atalla; Richard S. Reiner

    2002-01-01

    Lodgepole pine chips were pulped to Kappa numbers of about 70 using soda–AQ, soda–ODiMAQ, and kraft methods. At a catalyst level of 0.20% (oven-dry wood basis), cooking times for the soda cooks were significantly shorter than that for the kraft cook. The ODiMAQ catalyzed cooking time was much shorter than that of the AQ cook. It might be possible to replace the kraft...

  15. The effect of tonal changes on voice onset time in Mandarin esophageal speech.

    PubMed

    Liu, Hanjun; Ng, Manwa L; Wan, Mingxi; Wang, Supin; Zhang, Yi

    2008-03-01

    The present study investigated the effect of tonal changes on voice onset time (VOT) between normal laryngeal (NL) and superior esophageal (SE) speakers of Mandarin Chinese. VOT values were measured from the syllables /pha/, /tha/, and /kha/ produced at four tone levels by eight NL and seven SE speakers who were native speakers of Mandarin. Results indicated that Mandarin tones were associated with significantly different VOT values for NL speakers, in which high-falling tone was associated with significantly shorter VOT values than mid-rising tone and falling-rising tone. Regarding speaker group, SE speakers showed significantly shorter VOT values than NL speakers across all tone levels. This may be related to their use of pharyngoesophageal (PE) segment as another sound source. SE speakers appear to take a shorter time to start PE segment vibration compared to NL speakers using the vocal folds for vibration.

  16. How many hours do people sleep in Bangladesh? A country-representative survey.

    PubMed

    Yunus, Fakir M; Khan, Safayet; Akter, Tahera; Jhohura, Fatema T; Reja, Saifur; Islam, Akramul; Rahman, Mahfuzar

    2016-06-01

    This study investigated total sleep time in the Bangladeshi population and identified the proportion of the population at greater risk of developing chronic diseases due to inadequate sleep. Using a cross-sectional survey, total sleep time was captured and analysed in 3968 respondents aged between 6 and 106 years in 24 (of 64) districts in Bangladesh. Total sleep time was defined as the hours of total sleep in the previous 24 h. We used National Sleep Foundation (2015) guidelines to determine the recommended sleep hours in different age categories. Less or more than the recommended total sleep time (in hours) was considered 'shorter' and 'longer' sleep time, respectively. Linear and multinomial logistic regression models were used to determine the relationship between demographic variables and estimated risk of shorter and longer total sleep time. The mean (±standard deviation) total sleep time of children (6-13 years), teenagers (14-17 years), young adults and adults (18-64 years) and older adults (≥65 years) were 8.6 (±1.1), 8.1 (±1.0), 7.7 (±0.9) and 7.8 (±1.4) h, respectively, which were significantly different (P < 0.01). More than half of school-age children (55%) slept less than, and 28.2% of older adults slept longer than, recommended. Residents in all divisions (except Chittagong) in Bangladesh were less likely to sleep longer than in the Dhaka division. Rural populations had a 3.96× greater chance of sleeping for a shorter time than urban residents. The Bangladeshi population tends to sleep for longer and/or shorter times than their respective recommended sleep hours, which is detrimental to health. © 2016 European Sleep Research Society.

  17. Cross-National Applicability of a Parsimonious Measure of Acculturation to Global Consumer Culture.

    PubMed

    Gupta, Nitin

    2016-04-01

    Durvasula and Lysonski's paper presented a shorter version of the Acculturation to Global Consumer Culture Scale (hereafter AGCC), which was developed by Cleveland and Laroche to address scarcity of measurements that determined how individuals acquired and became a part of the emerging global consumer culture. The following critique discusses a few concerns and three major shortcomings of the paper, including skewed sample frame and incorrect choice of countries for assessing cross-national applicability of the scale, not discussing the differences in the means of the seven distinct dimensions of AGCC across the four nations studied by the authors, and absence of any critical review of existing consumer acculturation scales vis-à-vis AGCC. © The Author(s) 2016.

  18. First Update of the Criteria for Certification of Chest Pain Units in Germany: Facelift or New Model?

    PubMed

    Breuckmann, Frank; Rassaf, Tienush

    2016-03-01

    In an effort to provide a systematic and specific standard-of-care for patients with acute chest pain, the German Cardiac Society introduced criteria for certification of specialized chest pain units (CPUs) in 2008, which have been replaced by a recent update published in 2015. We reviewed the development of CPU establishment in Germany during the past 7 years and compared and commented the current update of the certification criteria. As of October 2015, 228 CPUs in Germany have been successfully certified by the German Cardiac Society; 300 CPUs are needed for full coverage closing gaps in rural regions. Current changes of the criteria mainly affect guideline-adherent adaptions of diagnostic work-ups, therapeutic strategies, risk stratification, in-hospital timing and education, and quality measures, whereas the overall structure remained unchanged. Benchmarking by participation within the German CPU registry is encouraged. Even though the history is short, the concept of certified CPUs in Germany is accepted and successful underlined by its recent implementation in national and international guidelines. First registry data demonstrated a high standard of quality-of-care. The current update provides rational adaptions to new guidelines and developments without raising the level for successful certifications. A periodic release of fast-track updates with shorter time frames and an increase of minimum requirements should be considered.

  19. Compensation of temporal and spatial dispersion for multiphoton acousto-optic laser-scanning microscopy

    NASA Astrophysics Data System (ADS)

    Iyer, Vijay; Saggau, Peter

    2003-10-01

    In laser-scanning microscopy, acousto-optic (AO) deflection provides a means to quickly position a laser beam to random locations throughout the field-of-view. Compared to conventional laser-scanning using galvanometer-driven mirrors, this approach increases the frame rate and signal-to-noise ratio, and reduces time spent illuminating sites of no interest. However, random-access AO scanning has not yet been combined with multi-photon microscopy, primarily because the femtosecond laser pulses employed are subject to significant amounts of both spatial and temporal dispersion upon propagation through common AO materials. Left uncompensated, spatial dispersion reduces the microscope"s spatial resolution while temporal dispersion reduces the multi-photon excitation efficacy. In previous work, we have demonstrated, 1) the efficacy of a single diffraction grating scheme which reduces the spatial dispersion at least 3-fold throughout the field-of-view, and 2) the use of a novel stacked-prism pre-chirper for compensating the temporal dispersion of a pair of AODs using a shorter mechanical path length (2-4X) than standard prism-pair arrangements. In this work, we demonstrate for the first time the use of these compensation approaches with a custom-made large-area slow-shear TeO2 AOD specifically suited for the development of a high-resolution 2-D random-access AO scanning multi-photon laser-scanning microscope (AO-MPLSM).

  20. Evaluation of Counter-Based Dynamic Load Balancing Schemes for Massive Contingency Analysis on Over 10,000 Cores

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Yousu; Huang, Zhenyu; Rice, Mark J.

    Contingency analysis studies are necessary to assess the impact of possible power system component failures. The results of the contingency analysis are used to ensure the grid reliability, and in power market operation for the feasibility test of market solutions. Currently, these studies are performed in real time based on the current operating conditions of the grid with a set of pre-selected contingency list, which might result in overlooking some critical contingencies caused by variable system status. To have a complete picture of a power grid, more contingencies need to be studied to improve grid reliability. High-performance computing techniques holdmore » the promise of being able to perform the analysis for more contingency cases within a much shorter time frame. This paper evaluates the performance of counter-based dynamic load balancing schemes for a massive contingency analysis program on 10,000+ cores. One million N-2 contingency analysis cases with a Western Electricity Coordinating Council power grid model have been used to demonstrate the performance. The speedup of 3964 with 4096 cores and 7877 with 10240 cores are obtained. This paper reports the performance of the load balancing scheme with a single counter and two counters, describes disk I/O issues, and discusses other potential techniques for further improving the performance.« less

  1. Report of the panel on earth rotation and reference frames, section 7

    NASA Technical Reports Server (NTRS)

    Dickey, Jean O.; Dickman, Steven R.; Eubanks, Marshall T.; Feissel, Martine; Herring, Thomas A.; Mueller, Ivan I.; Rosen, Richard D.; Schutz, Robert E.; Wahr, John M.; Wilson, Charles R.

    1991-01-01

    Objectives and requirements for Earth rotation and reference frame studies in the 1990s are discussed. The objectives are to observe and understand interactions of air and water with the rotational dynamics of the Earth, the effects of the Earth's crust and mantle on the dynamics and excitation of Earth rotation variations over time scales of hours to centuries, and the effects of the Earth's core on the rotational dynamics and the excitation of Earth rotation variations over time scales of a year or longer. Another objective is to establish, refine and maintain terrestrial and celestrial reference frames. Requirements include improvements in observations and analysis, improvements in celestial and terrestrial reference frames and reference frame connections, and improved observations of crustal motion and mass redistribution on the Earth.

  2. Solutions to Three-Dimensional Thin-Layer Navier-Stokes Equations in Rotating Coordinates for Flow Through Turbomachinery

    NASA Technical Reports Server (NTRS)

    Ghosh, Amrit Raj

    1996-01-01

    The viscous, Navier-Stokes solver for turbomachinery applications, MSUTC has been modified to include the rotating frame formulation. The three-dimensional thin-layer Navier-Stokes equations have been cast in a rotating Cartesian frame enabling the freezing of grid motion. This also allows the flow-field associated with an isolated rotor to be viewed as a steady-state problem. Consequently, local time stepping can be used to accelerate convergence. The formulation is validated by running NASA's Rotor 67 as the test case. results are compared between the rotating frame code and the absolute frame code. The use of the rotating frame approach greatly enhances the performance of the code with respect to savings in computing time, without degradation of the solution.

  3. --No Title--

    Science.gov Websites

    Column descriptions ID : Unique integer for each control time simulation LABEL : Description unique to each ID (see paper) Z : Redshift TIMEAREA : Observer-frame control time x area at 'Z' (year-arcmin ^2) Z2 : Second redshift TIMEVOL : Total rest-frame control time x volume between 'Z' and 'Z2' (year

  4. A brief note on Weyl frames and canonical transformations in geometrical scalar–tensor theories of gravity

    NASA Astrophysics Data System (ADS)

    Barreto, A. B.; Pucheu, M. L.; Romero, C.

    2018-02-01

    We consider scalar–tensor theories of gravity defined in Weyl integrable space-time and show that for time-lapse extended Robertson–Walker metrics in the ADM formalism a class of Weyl transformations corresponding to change of frames induce canonical transformations between different representations of the phase space. In this context, we discuss the physical equivalence of two distinct Weyl frames at the classical level.

  5. The influence of visual and vestibular orientation cues in a clock reading task.

    PubMed

    Davidenko, Nicolas; Cheong, Yeram; Waterman, Amanda; Smith, Jacob; Anderson, Barrett; Harmon, Sarah

    2018-05-23

    We investigated how performance in the real-life perceptual task of analog clock reading is influenced by the clock's orientation with respect to egocentric, gravitational, and visual-environmental reference frames. In Experiment 1, we designed a simple clock-reading task and found that observers' reaction time to correctly tell the time depends systematically on the clock's orientation. In Experiment 2, we dissociated egocentric from environmental reference frames by having participants sit upright or lie sideways while performing the task. We found that both reference frames substantially contribute to response times in this task. In Experiment 3, we placed upright or rotated participants in an upright or rotated immersive virtual environment, which allowed us to further dissociate vestibular from visual cues to the environmental reference frame. We found evidence of environmental reference frame effects only when visual and vestibular cues were aligned. We discuss the implications for the design of remote and head-mounted displays. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Contrast-enhanced magnetic resonance angiography: first-pass arterial enhancement as a function of gadolinium-chelate concentration, and the saline chaser volume and injection rate.

    PubMed

    Husarik, Daniela B; Bashir, Mustafa R; Weber, Paul W; Nichols, Eli B; Howle, Laurens E; Merkle, Elmar M; Nelson, Rendon C

    2012-02-01

    To evaluate the effect of the contrast medium (CM) concentration and the saline chaser volume and injection rate on first-pass aortic enhancement characteristics in contrast-enhanced magnetic resonance angiography using a physiologic flow phantom. Imaging was performed on a 3.0-T magnetic resonance system (MAGNETOM Trio, Siemens Healthcare Solutions, Inc, Erlangen, Germany) using a 2-dimensional fast low angle shot T1-weighted sequence (repetition time, 500 milliseconds; echo time, 1.23 milliseconds; flip angle, 8 degrees; 1 frame/s × 60 seconds). The following CM concentrations injected at 2 mL/s were used with 3 different contrast agents (gadolinium [Gd]-BOPTA, Gd-HP-DO3A, Gd-DTPA): 20 mL of undiluted CM (100%) and 80%, 40%, 20%, 10%, 5%, and 2.5% of the full amount, all diluted in saline to a volume of 20 mL to ensure equal bolus volume. The CM was followed by saline chasers of 20 to 60 mL injected at 2 mL/s and 6 mL/s. Aortic signal intensity (SI) was measured, and normalized SI versus time (SI/Tn) curves were generated. The maximal SI (SI(max)), bolus length, and areas under the SI/Tn curve were calculated. Decreasing the CM concentration from 100% to 40% resulted in a decrease of SI(max) to 86.1% (mean). Further decreasing the CM concentration to 2.5% decreased SI(max) to 5.1% (mean). Altering the saline chaser volume had no significant effect on SI(max). Increasing the saline chaser injection rate had little effect (mean increase, 2.2%) on SI(max) when using ≥40% of CM. There was a larger effect (mean increase, 19.6%) when ≤20% of CM were used. Bolus time length was significantly shorter (P < 0.001), and area under the SI/T(n) curve was significantly smaller (P < 0.01) for the CM protocols followed by a saline chaser injected at 6 mL/s compared with a saline chaser injected at 2 mL/s. With 40% of CM and a fast saline chaser, SImax close to that with undiluted CM can be achieved. An increased saline chaser injection rate has a more pronounced effect on aortic enhancement characteristics at lower CM concentrations than at higher CM concentrations.

  7. Transformative Relation of Kinematical Descriptive Quantities Defined by Different Spatial Referential Frame, Its Property and Application

    NASA Astrophysics Data System (ADS)

    Luo, Ji

    2012-08-01

    Quantitative transformations between corresponding kinetic quantities defined by any two spatial referential frames, whose relative kinematics relations (purely rotational and translational movement) are known, are presented based on necessarily descriptive definitions of the fundamental concepts (instant, time, spatial referential frame that distinguishes from Maths. Coordination, physical point) had being clarified by directly empirical observation with artificially descriptive purpose. Inductive investigation of the transformation reveals that all physical quantities such as charge, temperature, time, volume, length, temporal rate of the quantities and relations like temporal relation between signal source and observer as such are independent to spatial frames transformation except above kinematical quantities transformations, kinematics related dynamics such as Newton ’ s second law existing only in inertial frames and exchange of kinetic energy of mass being valid only in a selected inertial frame. From above bas is, we demonstrate a series of inferences and applications such as phase velocity of light being direct respect to medium (including vacuum) rather than to the frame, using spatial referential frame to describe any measurable field (electric field, magnetic field, gravitational field) and the field ’ s variation; and have tables to contrast and evaluate all aspects of those hypotheses related with spacetime such as distorted spacetime around massive stellar, four dimension spacetime, gravitational time dilation and non - Euclid geometry with new one. The demonstration strongly suggests all the hypotheses are invalid in capable tested concepts ’ meaning and relations. The conventional work on frame transformation and its property, hypothesized by Voigt, Heaviside, Lorentz, Poincare and Einstein a century ago with some mathematical speculation lacking rigorous definition of the fundamental concepts such as instant, time, spatial reference, straight line, plane area, merely good in building up patchwork to do self p referred explanation by making up derivative concepts or accumulating new hypothesis, has disturbed people to describe the physical nature by setting up the sound basis of concept and relations with capable tested method, it’s time to be replaced by empirically effective alternative.

  8. Time evolution of an SLR reference frame

    NASA Astrophysics Data System (ADS)

    Angermann, D.; Gerstl, M.; Kelm, R.; Müller, H.; Seemüller, W.; Vei, M.

    2002-07-01

    On the basis of LAGEOS-1 and LAGEOS-2 data we computed a 10-years (1990-2000) solution for SLR station positions and velocities. The paper describes the data processing with the DGFI software package DOGS. We present results for station coordinates and their time variation for 41 stations of the global SLR network, and discuss the stability and time evolution of the SLR reference frame established in the same way. We applied different methods to assess the quality and consistency of the SLR results. The results presented in this paper include: (1) a time series of weekly estimated station coordinates; (2) a comparison of a 10-year LAGEOS-1 and LAGEOS-2 solution; (3) a comparison of 2.5-year solutions with the combined 10-year solution to assess the internal stability and the time evolution of the SLR reference frame; (4) a comparison of the SLR reference frame with ITRF97; and (5) a comparison of SLR station velocities with those of ITRF97 and NNR NUVEL-1A.

  9. Bicycle weight and commuting time: randomised trial.

    PubMed

    Groves, J

    2010-12-09

    To determine whether the author's 20.9 lb (9.5 kg) carbon frame bicycle reduced commuting time compared with his 29.75 lb (13.5 kg) steel frame bicycle. Randomised trial. Sheffield and Chesterfield, United Kingdom, between mid-January 2010 and mid-July 2010. One consultant in anaesthesia and intensive care. Total time to complete the 27 mile (43.5 kilometre) journey from Sheffield to Chesterfield Royal Hospital and back. The total distance travelled on the steel frame bicycle during the study period was 809 miles (1302 km) and on the carbon frame bicycle was 711 miles (1144 km). The difference in the mean journey time between the steel and carbon bicycles was 00:00:32 (hr:min:sec; 95% CI -00:03:34 to 00:02:30; P=0.72). A lighter bicycle did not lead to a detectable difference in commuting time. Cyclists may find it more cost effective to reduce their own weight rather than to purchase a lighter bicycle.

  10. Serum Iron Level Is Associated with Time to Antibiotics in Cystic Fibrosis.

    PubMed

    Gifford, Alex H; Dorman, Dana B; Moulton, Lisa A; Helm, Jennifer E; Griffin, Mary M; MacKenzie, Todd A

    2015-12-01

    Serum levels of hepcidin-25, a peptide hormone that reduces blood iron content, are elevated when patients with cystic fibrosis (CF) develop pulmonary exacerbation (PEx). Because hepcidin-25 is unavailable as a clinical laboratory test, we questioned whether a one-time serum iron level was associated with the subsequent number of days until PEx, as defined by the need to receive systemic antibiotics (ABX) for health deterioration. Clinical, biochemical, and microbiological parameters were simultaneously checked in 54 adults with CF. Charts were reviewed to determine when they first experienced a PEx after these parameters were assessed. Time to ABX was compared in subgroups with and without specific attributes. Multivariate linear regression was used to identify parameters that significantly explained variation in time to ABX. In univariate analyses, time to ABX was significantly shorter in subjects with Aspergillus-positive sputum cultures and CF-related diabetes. Multivariate linear regression models demonstrated that shorter time to ABX was associated with younger age, lower serum iron level, and Aspergillus sputum culture positivity. Serum iron, age, and Aspergillus sputum culture positivity are factors associated with shorter time to subsequent PEx in CF adults. © 2015 Wiley Periodicals, Inc.

  11. Program Helps Generate And Manage Graphics

    NASA Technical Reports Server (NTRS)

    Truong, L. V.

    1994-01-01

    Living Color Frame Maker (LCFM) computer program generates computer-graphics frames. Graphical frames saved as text files, in readable and disclosed format, easily retrieved and manipulated by user programs for wide range of real-time visual information applications. LCFM implemented in frame-based expert system for visual aids in management of systems. Monitoring, diagnosis, and/or control, diagrams of circuits or systems brought to "life" by use of designated video colors and intensities to symbolize status of hardware components (via real-time feedback from sensors). Status of systems can be displayed. Written in C++ using Borland C++ 2.0 compiler for IBM PC-series computers and compatible computers running MS-DOS.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duchaineau, M.; Wolinsky, M.; Sigeti, D.E.

    Terrain visualization is a difficult problem for applications requiring accurate images of large datasets at high frame rates, such as flight simulation and ground-based aircraft testing using synthetic sensor stimulation. On current graphics hardware, the problem is to maintain dynamic, view-dependent triangle meshes and texture maps that produce good images at the required frame rate. We present an algorithm for constructing triangle meshes that optimizes flexible view-dependent error metrics, produces guaranteed error bounds, achieves specified triangle counts directly, and uses frame-to-frame coherence to operate at high frame rates for thousands of triangles per frame. Our method, dubbed Real-time Optimally Adaptingmore » Meshes (ROAM), uses two priority queues to drive split and merge operations that maintain continuous triangulations built from pre-processed bintree triangles. We introduce two additional performance optimizations: incremental triangle stripping and priority-computation deferral lists. ROAM execution time is proportionate to the number of triangle changes per frame, which is typically a few percent of the output mesh size, hence ROAM performance is insensitive to the resolution and extent of the input terrain. Dynamic terrain and simple vertex morphing are supported.« less

  13. Is conscious perception a series of discrete temporal frames?

    PubMed

    White, Peter A

    2018-04-01

    This paper reviews proposals that conscious perception consists, in whole or part, of successive discrete temporal frames on the sub-second time scale, each frame containing information registered as simultaneous or static. Although the idea of discrete frames in conscious perception cannot be regarded as falsified, there are many problems. Evidence does not consistently support any proposed duration or range of durations for frames. EEG waveforms provide evidence of periodicity in brain activity, but not necessarily in conscious perception. Temporal properties of perceptual processes are flexible in response to competing processing demands, which is hard to reconcile with the relative inflexibility of regular frames. There are also problems concerning the definition of frames, the need for informational connections between frames, the means by which boundaries between frames are established, and the apparent requirement for a storage buffer for information awaiting entry to the next frame. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Characteristics of revisits of children at risk for serious infections in pediatric emergency care.

    PubMed

    de Vos-Kerkhof, Evelien; Geurts, Dorien H F; Steyerberg, Ewout W; Lakhanpaul, Monica; Moll, Henriette A; Oostenbrink, Rianne

    2018-04-01

    In this study, we aimed to identify characteristics of (unscheduled) revisits and its optimal time frame after Emergency Department (ED) discharge. Children with fever, dyspnea, or vomiting/diarrhea (1 month-16 years) who attended the ED of Erasmus MC-Sophia, Rotterdam (2010-2013), the Netherlands, were prospectively included. Three days after ED discharge, we applied standardized telephonic questionnaires on disease course and revisits. Multivariable logistic regression analysis was used to identify independent characteristics of revisits. Young age, parental concern, and alarming signs and symptoms (chest wall retractions, ill appearance, clinical signs of dehydration, and tachypnea) were associated with revisits (n = 527) in children at risk for serious infections discharged from the ED (n = 1765). Children revisited the ED within a median of 2 days (IQR 1.0-3.0), but this was proven to be shorter in children with vomiting/diarrhea (1.0 day (IQR 1.0-2.0)) compared to children with fever or dyspnea (2.0 (IQR 1.0-3.0)). Young age, parental concern, and alarming signs and symptoms (chest wall retractions, ill appearance, clinical signs of dehydration, and tachypnea) were associated with emergency health care revisits in children with fever, dyspnea, and vomiting/diarrhea. These characteristics could help to define targeted review of children during post-discharge period. We observed a disease specific and differential timing of control revisits after ED discharge. What is Known • Fever, dyspnea, and vomiting/diarrhea are major causes of emergency care attendance in children. • As uncertainty remains on uneventful recovery, patients at risk need to be identified on order to improve safety netting after discharge from the ED. What is New • In children with fever, dyspnea, and vomiting/diarrhea, young age, parental concern and chest wall retractions, ill appearance, clinical signs of dehydration, and tachypnea help to define targeted review of children during the post-discharge period. • A revisit after ED discharge is disease-specific and seems to be shorter for children with vomiting/diarrhea than others.

  15. Quantum frames

    NASA Astrophysics Data System (ADS)

    Brown, Matthew J.

    2014-02-01

    The framework of quantum frames can help unravel some of the interpretive difficulties i the foundation of quantum mechanics. In this paper, I begin by tracing the origins of this concept in Bohr's discussion of quantum theory and his theory of complementarity. Engaging with various interpreters and followers of Bohr, I argue that the correct account of quantum frames must be extended beyond literal space-time reference frames to frames defined by relations between a quantum system and the exosystem or external physical frame, of which measurement contexts are a particularly important example. This approach provides superior solutions to key EPR-type measurement and locality paradoxes.

  16. Identifying Issue Frames in Text

    PubMed Central

    Sagi, Eyal; Diermeier, Daniel; Kaufmann, Stefan

    2013-01-01

    Framing, the effect of context on cognitive processes, is a prominent topic of research in psychology and public opinion research. Research on framing has traditionally relied on controlled experiments and manually annotated document collections. In this paper we present a method that allows for quantifying the relative strengths of competing linguistic frames based on corpus analysis. This method requires little human intervention and can therefore be efficiently applied to large bodies of text. We demonstrate its effectiveness by tracking changes in the framing of terror over time and comparing the framing of abortion by Democrats and Republicans in the U.S. PMID:23874909

  17. Anesthetic efficacy of ketamine-diazepam, ketamine-xylazine, and ketamine-acepromazine in Caspian Pond turtles (Mauremys caspica).

    PubMed

    Adel, Milad; Sadegh, Amin Bigham; Arizza, Vincenzo; Abbasi, Hossein; Inguglia, Luigi; Saravi, Hasan Nasrollahzadeh

    2017-01-01

    The objective of this study was to assess the efficacy of different anesthetic drug combinations on the Caspian Pond turtles ( Mauremys caspica ). Three groups of the Caspian Pond turtles ( n = 6) were anesthetized with three different drug combinations. Initially, a pilot study was conducted to determine the best drug doses for the anesthetization of the turtles, and according to these results, ketamine-diazepam (120 mg/kg ketamine hydrochloride [5%] and 2 mg/kg diazepam [5%]), ketamine-acepromazine (120 mg/kg ketamine hydrochloride [5%] and 1 mg/kg acepromazine [1%]), and ketamine-xylazine (120 mg/kg ketamine hydrochloride [5%] and 1 mg/kg xylazine [2%]) were injected intramuscularly. The onset times of anesthetization and the recovery time were measured. Statistical analysis of the data was performed using one-way analysis of variance followed by t -tests, and P < 0.05 was considered statistically significant. There were statistically significant differences in the mean of the onset times of anesthesia and recovery time among the three drug combinations depending on the treatment used. The onset of anesthesia of the animals treated with the ketamine-diazepam combination was 60% and 42% shorter, for male and female turtles, respectively, compared to that obtained with the ketamine-acepromazine combination and 64% (male turtles) and 50% (female turtles) shorter than that obtained with the ketamine-xylazine combination. Further, the recovery time, in male turtles, was 17% shorter in animals treated with the first drug combination than those treated with the ketamine-acepromazine combination and 37% shorter than those treated with the ketamine-xylazine combination. The recovery time, in female turtles, did not seem to be significantly different among treatments. The study showed that the ketamine-diazepam drug combination is the anesthetic combination with the fastest onset time and shortest recovery time.

  18. Noise reduction in single time frame optical DNA maps

    PubMed Central

    Müller, Vilhelm; Westerlund, Fredrik

    2017-01-01

    In optical DNA mapping technologies sequence-specific intensity variations (DNA barcodes) along stretched and stained DNA molecules are produced. These “fingerprints” of the underlying DNA sequence have a resolution of the order one kilobasepairs and the stretching of the DNA molecules are performed by surface adsorption or nano-channel setups. A post-processing challenge for nano-channel based methods, due to local and global random movement of the DNA molecule during imaging, is how to align different time frames in order to produce reproducible time-averaged DNA barcodes. The current solutions to this challenge are computationally rather slow. With high-throughput applications in mind, we here introduce a parameter-free method for filtering a single time frame noisy barcode (snap-shot optical map), measured in a fraction of a second. By using only a single time frame barcode we circumvent the need for post-processing alignment. We demonstrate that our method is successful at providing filtered barcodes which are less noisy and more similar to time averaged barcodes. The method is based on the application of a low-pass filter on a single noisy barcode using the width of the Point Spread Function of the system as a unique, and known, filtering parameter. We find that after applying our method, the Pearson correlation coefficient (a real number in the range from -1 to 1) between the single time-frame barcode and the time average of the aligned kymograph increases significantly, roughly by 0.2 on average. By comparing to a database of more than 3000 theoretical plasmid barcodes we show that the capabilities to identify plasmids is improved by filtering single time-frame barcodes compared to the unfiltered analogues. Since snap-shot experiments and computational time using our method both are less than a second, this study opens up for high throughput optical DNA mapping with improved reproducibility. PMID:28640821

  19. Facial palsy in children: emergency department management and outcome.

    PubMed

    Wang, Cheng-Hsien; Chang, Yu-Che; Shih, Hong-Mo; Chen, Chun-Yu; Chen, Jih-Chang

    2010-02-01

    To describe the characteristics of children who present to an emergency department (ED) with facial palsy and determine the association of outcome with etiology, degree of initial paralysis, and ED management. This was a retrospective cohort study of children who presented to an ED with facial nerve paralysis (FNP). There were 85 patients with a mean age of 8.0 (SD, 6.1) years; 60% (n = 51) of the patients were male, and 65.9% (n = 56) were admitted to the hospital. Bell palsy (50.6%) was the most common etiology followed by infectious (22.4%), traumatic (16.5%), congenital (7.1%), and neoplastic etiologies (3.5%). Patients with Bell palsy had shorter recovery times (P = 0.049), and traumatic cases required a longer time for recovery (P = 0.016). Acute otitis media (AOM)-related pediatric FNP had shorter recovery times than non-AOM-related cases (P = 0.005) in infectious group. Patients given steroid therapy did not have a shorter recovery time (P = 0.237) or a better recovery (P = 0.269). There was no difference in recovery rate of pediatric patients with Bell palsy between hospitalization or not (P = 0.952). Bell palsy, infection, and trauma were most common etiologies of pediatric FNP. Recovery times were shorter in pediatric patients with Bell palsy and AOM-related FNP, whereas recovery took longer in traumatic cases. Steroid therapy did not seem beneficial for pediatric FNP. Hospitalization is not indicated for pediatric patients with Bell palsy.

  20. A study of applications scribe frame data verifications using design rule check

    NASA Astrophysics Data System (ADS)

    Saito, Shoko; Miyazaki, Masaru; Sakurai, Mitsuo; Itoh, Takahisa; Doi, Kazumasa; Sakurai, Norioko; Okada, Tomoyuki

    2013-06-01

    In semiconductor manufacturing, scribe frame data generally is generated for each LSI product according to its specific process design. Scribe frame data is designed based on definition tables of scanner alignment, wafer inspection and customers specified marks. We check that scribe frame design is conforming to specification of alignment and inspection marks at the end. Recently, in COT (customer owned tooling) business or new technology development, there is no effective verification method for the scribe frame data, and we take a lot of time to work on verification. Therefore, we tried to establish new verification method of scribe frame data by applying pattern matching and DRC (Design Rule Check) which is used in device verification. We would like to show scheme of the scribe frame data verification using DRC which we tried to apply. First, verification rules are created based on specifications of scanner, inspection and others, and a mark library is also created for pattern matching. Next, DRC verification is performed to scribe frame data. Then the DRC verification includes pattern matching using mark library. As a result, our experiments demonstrated that by use of pattern matching and DRC verification our new method can yield speed improvements of more than 12 percent compared to the conventional mark checks by visual inspection and the inspection time can be reduced to less than 5 percent if multi-CPU processing is used. Our method delivers both short processing time and excellent accuracy when checking many marks. It is easy to maintain and provides an easy way for COT customers to use original marks. We believe that our new DRC verification method for scribe frame data is indispensable and mutually beneficial.

  1. NChina16: A stable geodetic reference frame for geological hazard studies in North China

    NASA Astrophysics Data System (ADS)

    Wang, Guoquan; Bao, Yan; Gan, Weijun; Geng, Jianghui; Xiao, Gengru; Shen, Jack S.

    2018-04-01

    We have developed a stable North China Reference Frame 2016 (NChina16) using five years of continuous GPS observations (2011.8-2016.8) from 12 continuously operating reference stations (CORS) fixed to the North China Craton. Applications of NChina16 in landslide and subsidence studies are illustrated in this article. A method for realizing a regional geodetic reference frame is introduced. The primary result of this study is the seven parameters for transforming Cartesian ECEF (Earth-Centered, Earth-Fixed) coordinates X, Y, and Z from the International GNSS Service Reference Frame 2008 (IGS08) to NChina16. The seven parameters include the epoch that is used to align the regional reference frame to IGS08 and the time derivatives of three translations and three rotations. The GIPSY-OASIS (V6.4) software package was used to obtain the precise point positioning (PPP) daily solutions with respect to IGS08. The frame stability of NChina16 is approximately 0.5 mm/year in both horizontal and vertical directions. This study also developed a regional model for correcting seasonal motions superimposed into the vertical component of the GPS-derived displacement time series. Long-term GPS observations (1999-2016) from five CORS in North China were used to develop the seasonal model. According to this study, the PPP daily solutions with respect to NChina16 could achieve 2-3 mm horizontal accuracy and 4-5 mm vertical accuracy after being modified by the regional model. NChina16 will be critical to study geodynamic problems in North China, such as earthquakes, faulting, subsidence, and landslides. The regional reference frame will be periodically updated every few years to mitigate degradation of the frame with time and be synchronized with the update of IGS reference frame.

  2. A framed, 16-image Kirkpatrick–Baez x-ray microscope

    DOE PAGES

    Marshall, F. J.; Bahr, R. E.; Goncharov, V. N.; ...

    2017-09-08

    A 16-image Kirkpatrick–Baez (KB)–type x-ray microscope consisting of compact KB mirrors has been assembled for the first time with mirrors aligned to allow it to be coupled to a high-speed framing camera. The high-speed framing camera has four independently gated strips whose emission sampling interval is ~30 ps. Images are arranged four to a strip with ~60-ps temporal spacing between frames on a strip. By spacing the timing of the strips, a frame spacing of ~15 ps is achieved. A framed resolution of ~6-um is achieved with this combination in a 400-um region of laser–plasma x-ray emission in the 2-more » to 8-keV energy range. A principal use of the microscope is to measure the evolution of the implosion stagnation region of cryogenic DT target implosions on the University of Rochester’s OMEGA Laser System. The unprecedented time and spatial resolution achieved with this framed, multi-image KB microscope have made it possible to accurately determine the cryogenic implosion core emission size and shape at the peak of stagnation. In conclusion, these core size measurements, taken in combination with those of ion temperature, neutron-production temporal width, and neutron yield allow for inference of core pressures, currently exceeding 50 GBar in OMEGA cryogenic target implosions.« less

  3. A framed, 16-image Kirkpatrick–Baez x-ray microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, F. J.; Bahr, R. E.; Goncharov, V. N.

    A 16-image Kirkpatrick–Baez (KB)–type x-ray microscope consisting of compact KB mirrors has been assembled for the first time with mirrors aligned to allow it to be coupled to a high-speed framing camera. The high-speed framing camera has four independently gated strips whose emission sampling interval is ~30 ps. Images are arranged four to a strip with ~60-ps temporal spacing between frames on a strip. By spacing the timing of the strips, a frame spacing of ~15 ps is achieved. A framed resolution of ~6-um is achieved with this combination in a 400-um region of laser–plasma x-ray emission in the 2-more » to 8-keV energy range. A principal use of the microscope is to measure the evolution of the implosion stagnation region of cryogenic DT target implosions on the University of Rochester’s OMEGA Laser System. The unprecedented time and spatial resolution achieved with this framed, multi-image KB microscope have made it possible to accurately determine the cryogenic implosion core emission size and shape at the peak of stagnation. In conclusion, these core size measurements, taken in combination with those of ion temperature, neutron-production temporal width, and neutron yield allow for inference of core pressures, currently exceeding 50 GBar in OMEGA cryogenic target implosions.« less

  4. Suppression and Narrative Time Shifts in Adults with Right-Hemisphere Brain Damage

    ERIC Educational Resources Information Center

    Scharp, Victoria L.; Tompkins, Connie A.

    2013-01-01

    Purpose: This study examined the functioning of a central comprehension mechanism, suppression, in adults with right-hemisphere damage (RHD) while they processed narratives that cued a shift in time frame. In normal language comprehension, mental activation of concepts from a prior time frame is suppressed. The (re)activation of information…

  5. A geometric rationale for invariance, covariance and constitutive relations

    NASA Astrophysics Data System (ADS)

    Romano, Giovanni; Barretta, Raffaele; Diaco, Marina

    2018-01-01

    There are, in each branch of science, statements which, expressed in ambiguous or even incorrect but seemingly friendly manner, were repeated for a long time and eventually became diffusely accepted. Objectivity of physical fields and of their time rates and frame indifference of constitutive relations are among such notions. A geometric reflection on the description of frame changes as spacetime automorphisms, on induced push-pull transformations and on proper physico-mathematical definitions of material, spatial and spacetime tensor fields and of their time-derivatives along the motion, is here carried out with the aim of pointing out essential notions and of unveiling false claims. Theoretical and computational aspects of nonlinear continuum mechanics, and especially those pertaining to constitutive relations, involving material fields and their time rates, gain decisive conceptual and operative improvement from a proper geometric treatment. Outcomes of the geometric analysis are frame covariance of spacetime velocity, material stretching and material spin. A univocal and frame-covariant tool for evaluation of time rates of material fields is provided by the Lie derivative along the motion. The postulate of frame covariance of material fields is assessed to be a natural physical requirement which cannot interfere with the formulation of constitutive laws, with claims of the contrary stemming from an improper imposition of equality in place of equivalence.

  6. Nonequilibrium dynamics of the O( N ) model on dS3 and AdS crunches

    NASA Astrophysics Data System (ADS)

    Kumar, S. Prem; Vaganov, Vladislav

    2018-03-01

    We study the nonperturbative quantum evolution of the interacting O( N ) vector model at large- N , formulated on a spatial two-sphere, with time dependent couplings which diverge at finite time. This model - the so-called "E-frame" theory, is related via a conformal transformation to the interacting O( N ) model in three dimensional global de Sitter spacetime with time independent couplings. We show that with a purely quartic, relevant deformation the quantum evolution of the E-frame model is regular even when the classical theory is rendered singular at the end of time by the diverging coupling. Time evolution drives the E-frame theory to the large- N Wilson-Fisher fixed point when the classical coupling diverges. We study the quantum evolution numerically for a variety of initial conditions and demonstrate the finiteness of the energy at the classical "end of time". With an additional (time dependent) mass deformation, quantum backreaction lowers the mass, with a putative smooth time evolution only possible in the limit of infinite quartic coupling. We discuss the relevance of these results for the resolution of crunch singularities in AdS geometries dual to E-frame theories with a classical gravity dual.

  7. Temporal enhancement of two-dimensional color doppler echocardiography

    NASA Astrophysics Data System (ADS)

    Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.

    2016-03-01

    Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.

  8. A motion-tolerant approach for monitoring SpO2 and heart rate using photoplethysmography signal with dual frame length processing and multi-classifier fusion.

    PubMed

    Fan, Feiyi; Yan, Yuepeng; Tang, Yongzhong; Zhang, Hao

    2017-12-01

    Monitoring pulse oxygen saturation (SpO 2 ) and heart rate (HR) using photoplethysmography (PPG) signal contaminated by a motion artifact (MA) remains a difficult problem, especially when the oximeter is not equipped with a 3-axis accelerometer for adaptive noise cancellation. In this paper, we report a pioneering investigation on the impact of altering the frame length of Molgedey and Schuster independent component analysis (ICAMS) on performance, design a multi-classifier fusion strategy for selecting the PPG correlated signal component, and propose a novel approach to extract SpO 2 and HR readings from PPG signal contaminated by strong MA interference. The algorithm comprises multiple stages, including dual frame length ICAMS, a multi-classifier-based PPG correlated component selector, line spectral analysis, tree-based HR monitoring, and post-processing. Our approach is evaluated by multi-subject tests. The root mean square error (RMSE) is calculated for each trial. Three statistical metrics are selected as performance evaluation criteria: mean RMSE, median RMSE and the standard deviation (SD) of RMSE. The experimental results demonstrate that a shorter ICAMS analysis window probably results in better performance in SpO 2 estimation. Notably, the designed multi-classifier signal component selector achieved satisfactory performance. The subject tests indicate that our algorithm outperforms other baseline methods regarding accuracy under most criteria. The proposed work can contribute to improving the performance of current pulse oximetry and personal wearable monitoring devices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Internet Video Telephony Allows Speech Reading by Deaf Individuals and Improves Speech Perception by Cochlear Implant Users

    PubMed Central

    Mantokoudis, Georgios; Dähler, Claudia; Dubach, Patrick; Kompis, Martin; Caversaccio, Marco D.; Senn, Pascal

    2013-01-01

    Objective To analyze speech reading through Internet video calls by profoundly hearing-impaired individuals and cochlear implant (CI) users. Methods Speech reading skills of 14 deaf adults and 21 CI users were assessed using the Hochmair Schulz Moser (HSM) sentence test. We presented video simulations using different video resolutions (1280×720, 640×480, 320×240, 160×120 px), frame rates (30, 20, 10, 7, 5 frames per second (fps)), speech velocities (three different speakers), webcameras (Logitech Pro9000, C600 and C500) and image/sound delays (0–500 ms). All video simulations were presented with and without sound and in two screen sizes. Additionally, scores for live Skype™ video connection and live face-to-face communication were assessed. Results Higher frame rate (>7 fps), higher camera resolution (>640×480 px) and shorter picture/sound delay (<100 ms) were associated with increased speech perception scores. Scores were strongly dependent on the speaker but were not influenced by physical properties of the camera optics or the full screen mode. There is a significant median gain of +8.5%pts (p = 0.009) in speech perception for all 21 CI-users if visual cues are additionally shown. CI users with poor open set speech perception scores (n = 11) showed the greatest benefit under combined audio-visual presentation (median speech perception +11.8%pts, p = 0.032). Conclusion Webcameras have the potential to improve telecommunication of hearing-impaired individuals. PMID:23359119

  10. Do you want the good news or the bad news? Gain- versus loss-framed messages following health risk information: The effects on leisure time physical activity beliefs and cognitions.

    PubMed

    Bassett-Gunter, Rebecca L; Martin Ginis, Kathleen A; Latimer-Cheung, Amy E

    2013-12-01

    The primary purpose was to examine the relative effectiveness of chronic disease and psychological health risk information combined with gain- versus loss-framed leisure time physical activity (LTPA) messages for changing perceived personal risk, LTPA response efficacy (i.e., the belief that LTPA can effectively reduce risk), and LTPA intentions. A secondary purpose was to explore the relationship between message framing and cognitive processing. Baseline assessments of perceived risk for inactivity-related disease and psychological health problems, LTPA response efficacy, and intentions were measured among 96 individuals with spinal cord injury (SCI). Participants read population-specific information about the risk for inactivity-related disease and psychological health problems following SCI, and perceived risk was reassessed. Participants were then randomized to read LTPA response efficacy messages emphasizing the benefits of LTPA (gain framed) or the risks of inactivity (loss framed). Immediately following message exposure, cognitive processing (i.e., thought listing and message recall), LTPA response efficacy, and LTPA intentions were assessed. Changes in perceived risk were observed following exposure to health risk information. Changes in LTPA response efficacy and intentions were greater following loss-framed messages targeting psychological health compared with gain-framed messages. Greater cognitive processing was observed following loss-framed messages compared with gain-framed messages. Following exposure to psychological health risk information, loss-framed messages may be more effective than gain-framed messages for eliciting cognitive processing and changing LTPA beliefs and intentions.

  11. Persuading People to Drink Less Alcohol: The Role of Message Framing, Temporal Focus and Autonomy.

    PubMed

    Churchill, Susan; Pavey, Louisa; Jessop, Donna; Sparks, Paul

    2016-11-01

    Health information can be used to try to persuade people to follow safe drinking recommendations. However, both the framing of information and the dispositional characteristics of message recipients need to be considered. An online study was conducted to examine how level of autonomy moderated the effect on drinking behaviour of gain- and loss-framed messages about the short- vs. long-term consequences of alcohol use. At Time 1, participants (N = 335) provided demographic information and completed a measure of autonomy. At Time 2, participants reported baseline alcohol use and read a gain-framed or loss-framed health message that highlighted either short- or long-term outcomes of alcohol consumption. Alcohol consumption was reported 7 days later. The results showed a significant three-way interaction between message framing (loss vs. gain), temporal focus (short-term vs. long-term) and autonomy. For low-autonomy (but not high-autonomy) individuals, the loss-framed health message was associated with lower levels of alcohol consumption than was the gain-framed message but only if the short-term outcomes were conveyed. This research provides evidence that the interaction between message framing and temporal focus may depend on a person's level of autonomy, which has implications for health promotion and the construction of effective health communication messages. We examined how autonomy moderated the effect on drinking behaviour of gain- and loss-framed messages about the short- vs. long-term consequences of alcohol use. For low-autonomy individuals, the loss-framed health message was associated with lower alcohol consumption than was the gain-framed message but only if the short-term outcomes were conveyed. © The Author 2016. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  12. Design of Visco-Elastic Dampers for RC Frame for Site-Specific Earthquake

    NASA Astrophysics Data System (ADS)

    Kamatchi, P.; Rama Raju, K.; Ravisankar, K.; Iyer, Nagesh R.

    2016-12-01

    Number of Reinforced Concrete (RC) framed buildings have got damaged at Ahmedabad city, India located at about 240 km away from epicenter during January 2001, 7.6 moment magnitude (Mw) Bhuj earthquake. In the present study, two dimensional nonlinear time history dynamic analyses of a typical 13 storey frame assumed to be located at Ahmedabad is carried out with the rock level and surface level site-specific ground motion for scenario earthquake of Mw 7.6 from Bhuj. Artificial ground motions are generated using extended finite source stochastic model with seismological parameters reported in literature for 2001 Bhuj earthquake. Surface level ground motions are obtained for a typical soil profile of 100 m depth reported in literature through one dimensional equivalent linear wave propagation analyses. From the analyses, failure of frame is observed for surface level ground motions which indicates that, in addition to the in-adequacy of the cross sections and reinforcement of the RC members of the frame chosen, the rich energy content of the surface level ground motion near the fundamental time period of the frame has also contributed for the failure of frame. As a part of retrofitting measure, five Visco-elastic Dampers (VED) in chevron bracing are added to frame. For the frame considered in the present study, provision of VED is found to be effective to mitigate damage for the soil site considered.

  13. Outcome after introduction of laparoscopic appendectomy in children: A cohort study.

    PubMed

    Svensson, Jan F; Patkova, Barbora; Almström, Markus; Eaton, Simon; Wester, Tomas

    2016-03-01

    Acute appendicitis in children is common and the optimal treatment modality is still debated, even if recent data suggest that laparoscopic surgery may result in shorter postoperative length of stay without an increased number of complications. The aim of the study was to compare the outcome of open and laparoscopic appendectomies during a transition period. This was a retrospective cohort study with prospectively collected data. All patients who underwent an operation for suspected appendicitis at the Astrid Lindgren Children's Hospital in Stockholm between 2006 and 2010 were included in the study. 1745 children were included in this study, of whom 1010 had a laparoscopic intervention. There were no significant differences in the rate of postoperative abscesses, wound infections, readmissions or reoperations between the two groups. The median operating time was longer for laparoscopic appendectomy than for open appendectomy, 51 vs. 37minutes (p<0.05). The postoperative length of stay was similar in the two groups. A simple comparison between the groups suggested that laparoscopic appendectomy had a shorter median postoperative length of stay, 43 vs. 57hours (p<0.05). However, there was a trend in time for a shorter postoperative length of stay, and a trend for more of the procedures to be performed laparoscopically over time so on regression analysis, the apparent decrease in length of stay with laparoscopy could be ascribed to the general trend toward decreased length of stay over time, with no specific additional effect of laparoscopy. Our data show no difference in outcome between open and laparoscopic surgery for acute appendicitis in children in regard of complications. The initial assumption that the patients treated with laparoscopic surgery had a shorter postoperative stay was not confirmed with linear regression, which showed that the assumed difference was due only to a trend toward shorter postoperative length of stay over time, regardless of the surgical intervention. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Mid-Ventilation Concept for Mobile Pulmonary Tumors: Internal Tumor Trajectory Versus Selective Reconstruction of Four-Dimensional Computed Tomography Frames Based on External Breathing Motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guckenberger, Matthias; Wilbert, Juergen; Krieger, Thomas

    2009-06-01

    Purpose: To evaluate the accuracy of direct reconstruction of mid-ventilation and peak-phase four-dimensional (4D) computed tomography (CT) frames based on the external breathing signal. Methods and Materials: For 11 patients with 15 pulmonary targets, a respiration-correlated CT study (4D CT) was acquired for treatment planning. After retrospective time-based sorting of raw projection data and reconstruction of eight CT frames equally distributed over the breathing cycle, mean tumor position (P{sub mean}), mid-ventilation frame, and breathing motion were evaluated based on the internal tumor trajectory. Analysis of the external breathing signal (pressure sensor around abdomen) with amplitude-based sorting of projections was performedmore » for direct reconstruction of the mid-ventilation frame and frames at peak phases of the breathing cycle. Results: On the basis of the eight 4D CT frames equally spaced in time, tumor motion was largest in the craniocaudal direction, with 12 {+-} 7 mm on average. Tumor motion between the two frames reconstructed at peak phases was not different in the craniocaudal and anterior-posterior directions but was systematically smaller in the left-right direction by 1 mm on average. The 3-dimensional distance between P{sub mean} and the tumor position in the mid-ventilation frame based on the internal tumor trajectory was 1.2 {+-} 1 mm. Reconstruction of the mid-ventilation frame at the mean amplitude position of the external breathing signal resulted in tumor positions 2.0 {+-} 1.1 mm distant from P{sub mean}. Breathing-induced motion artifacts in mid-ventilation frames caused negligible changes in tumor volume and shape. Conclusions: Direct reconstruction of the mid-ventilation frame and frames at peak phases based on the external breathing signal was reliable. This makes the reconstruction of only three 4D CT frames sufficient for application of the mid-ventilation technique in clinical practice.« less

  15. Simultaneous image reproduction on CRT screen: Moves ultrasonic sectional view and electrocardiogram curves

    NASA Technical Reports Server (NTRS)

    1978-01-01

    A method for simultaneous reproduction of images, requiring different amounts of time to reproduce, on a cathode ray tube (CRT) screen is disclosed. Ultrasonic sectional views and electrocardiogram curves are simultaneously reproduced on the CRT screen by producing the images on different areas of a screen with two phosphors having different persistence times and luminous colors, within the times required for the appearance of the images. In front of the area on which is produced the image requiring the shorter time is a color filter which is permeable to the color of the phosphor with the shorter persistence time by which absorbs the color of the other phosphor.

  16. A typology of time-scale mismatches and behavioral interventions to diagnose and solve conservation problems

    USGS Publications Warehouse

    Wilson, Robyn S.; Hardisty, David J.; Epanchin-Niell, Rebecca S.; Runge, Michael C.; Cottingham, Kathryn L.; Urban, Dean L.; Maguire, Lynn A.; Hastings, Alan; Mumby, Peter J.; Peters, Debra P.C.

    2016-01-01

    Ecological systems often operate on time scales significantly longer or shorter than the time scales typical of human decision making, which causes substantial difficulty for conservation and management in socioecological systems. For example, invasive species may move faster than humans can diagnose problems and initiate solutions, and climate systems may exhibit long-term inertia and short-term fluctuations that obscure learning about the efficacy of management efforts in many ecological systems. We adopted a management-decision framework that distinguishes decision makers within public institutions from individual actors within the social system, calls attention to the ways socioecological systems respond to decision makers’ actions, and notes institutional learning that accrues from observing these responses. We used this framework, along with insights from bedeviling conservation problems, to create a typology that identifies problematic time-scale mismatches occurring between individual decision makers in public institutions and between individual actors in the social or ecological system. We also considered solutions that involve modifying human perception and behavior at the individual level as a means of resolving these problematic mismatches. The potential solutions are derived from the behavioral economics and psychology literature on temporal challenges in decision making, such as the human tendency to discount future outcomes at irrationally high rates. These solutions range from framing environmental decisions to enhance the salience of long-term consequences, to using structured decision processes that make time scales of actions and consequences more explicit, to structural solutions aimed at altering the consequences of short-sighted behavior to make it less appealing. Additional application of these tools and long-term evaluation measures that assess not just behavioral changes but also associated changes in ecological systems are needed.

  17. Mapping Diffusion in a Living Cell via the Phasor Approach

    PubMed Central

    Ranjit, Suman; Lanzano, Luca; Gratton, Enrico

    2014-01-01

    Diffusion of a fluorescent protein within a cell has been measured using either fluctuation-based techniques (fluorescence correlation spectroscopy (FCS) or raster-scan image correlation spectroscopy) or particle tracking. However, none of these methods enables us to measure the diffusion of the fluorescent particle at each pixel of the image. Measurement using conventional single-point FCS at every individual pixel results in continuous long exposure of the cell to the laser and eventual bleaching of the sample. To overcome this limitation, we have developed what we believe to be a new method of scanning with simultaneous construction of a fluorescent image of the cell. In this believed new method of modified raster scanning, as it acquires the image, the laser scans each individual line multiple times before moving to the next line. This continues until the entire area is scanned. This is different from the original raster-scan image correlation spectroscopy approach, where data are acquired by scanning each frame once and then scanning the image multiple times. The total time of data acquisition needed for this method is much shorter than the time required for traditional FCS analysis at each pixel. However, at a single pixel, the acquired intensity time sequence is short; requiring nonconventional analysis of the correlation function to extract information about the diffusion. These correlation data have been analyzed using the phasor approach, a fit-free method that was originally developed for analysis of FLIM images. Analysis using this method results in an estimation of the average diffusion coefficient of the fluorescent species at each pixel of an image, and thus, a detailed diffusion map of the cell can be created. PMID:25517145

  18. A typology of time-scale mismatches and behavioral interventions to diagnose and solve conservation problems.

    PubMed

    Wilson, Robyn S; Hardisty, David J; Epanchin-Niell, Rebecca S; Runge, Michael C; Cottingham, Kathryn L; Urban, Dean L; Maguire, Lynn A; Hastings, Alan; Mumby, Peter J; Peters, Debra P C

    2016-02-01

    Ecological systems often operate on time scales significantly longer or shorter than the time scales typical of human decision making, which causes substantial difficulty for conservation and management in socioecological systems. For example, invasive species may move faster than humans can diagnose problems and initiate solutions, and climate systems may exhibit long-term inertia and short-term fluctuations that obscure learning about the efficacy of management efforts in many ecological systems. We adopted a management-decision framework that distinguishes decision makers within public institutions from individual actors within the social system, calls attention to the ways socioecological systems respond to decision makers' actions, and notes institutional learning that accrues from observing these responses. We used this framework, along with insights from bedeviling conservation problems, to create a typology that identifies problematic time-scale mismatches occurring between individual decision makers in public institutions and between individual actors in the social or ecological system. We also considered solutions that involve modifying human perception and behavior at the individual level as a means of resolving these problematic mismatches. The potential solutions are derived from the behavioral economics and psychology literature on temporal challenges in decision making, such as the human tendency to discount future outcomes at irrationally high rates. These solutions range from framing environmental decisions to enhance the salience of long-term consequences, to using structured decision processes that make time scales of actions and consequences more explicit, to structural solutions aimed at altering the consequences of short-sighted behavior to make it less appealing. Additional application of these tools and long-term evaluation measures that assess not just behavioral changes but also associated changes in ecological systems are needed. © 2015 Society for Conservation Biology.

  19. Framing of task performance strategies: effects on performance in a multiattribute dynamic decision making environment.

    PubMed

    Nygren, T E

    1997-09-01

    It is well documented that the way a static choice task is "framed" can dramatically alter choice behavior, often leading to observable preference reversals. This framing effect appears to result from perceived changes in the nature or location of a person's initial reference point, but it is not clear how framing effects might generalize to performance on dynamic decision making tasks that are characterized by high workload, time constraints, risk, or stress. A study was conducted to examine the hypothesis that framing can introduce affective components to the decision making process and can influence, either favorably (positive frame) or adversely (negative frame), the implementation and use of decision making strategies in dynamic high-workload environments. Results indicated that negative frame participants were significantly impaired in developing and employing a simple optimal decision strategy relative to a positive frame group. Discussion focuses on implications of these results for models of dynamic decision making.

  20. A fast double shutter for CCD-based metrology

    NASA Astrophysics Data System (ADS)

    Geisler, R.

    2017-02-01

    Image based metrology such as Particle Image Velocimetry (PIV) depends on the comparison of two images of an object taken in fast succession. Cameras for these applications provide the so-called `double shutter' mode: One frame is captured with a short exposure time and in direct succession a second frame with a long exposure time can be recorded. The difference in the exposure times is typically no problem since illumination is provided by a pulsed light source such as a laser and the measurements are performed in a darkened environment to prevent ambient light from accumulating in the long second exposure time. However, measurements of self-luminous processes (e.g. plasma, combustion ...) as well as experiments in ambient light are difficult to perform and require special equipment (external shutters, highspeed image sensors, multi-sensor systems ...). Unfortunately, all these methods incorporate different drawbacks such as reduced resolution, degraded image quality, decreased light sensitivity or increased susceptibility to decalibration. In the solution presented here, off-the-shelf CCD sensors are used with a special timing to combine neighbouring pixels in a binning-like way. As a result, two frames of short exposure time can be captured in fast succession. They are stored in the on-chip vertical register in a line-interleaved pattern, read out in the common way and separated again by software. The two resultant frames are completely congruent; they expose no insensitive lines or line shifts and thus enable sub-pixel accurate measurements. A third frame can be captured at the full resolution analogue to the double shutter technique. Image based measurement techniques such as PIV can benefit from this mode when applied in bright environments. The third frame is useful e.g. for acceleration measurements or for particle tracking applications.

  1. A prospective interrupted time series study of interventions to improve the quality, rating, framing and structure of goal-setting in community-based brain injury rehabilitation.

    PubMed

    Hassett, Leanne; Simpson, Grahame; Cotter, Rachel; Whiting, Diane; Hodgkinson, Adeline; Martin, Diane

    2015-04-01

    To investigate whether the introduction of an electronic goals system followed by staff training improved the quality, rating, framing and structure of goals written by a community-based brain injury rehabilitation team. Interrupted time series design. Two interventions were introduced six months apart. The first intervention comprised the introduction of an electronic goals system. The second intervention comprised a staff goal training workshop. An audit protocol was devised to evaluate the goals. A random selection of goal statements from the 12 months prior to the interventions (Time 1 baseline) were compared with all goal statements written after the introduction of the electronic goals system (Time 2) and staff training (Time 3). All goals were de-identified for client and time-period, and randomly ordered. A total of 745 goals (Time 1 n = 242; Time 2 n = 283; Time 3 n = 220) were evaluated. Compared with baseline, the introduction of the electronic goals system alone significantly increased goal rating, framing and structure (χ(2) tests 144.7, 18.9, 48.1, respectively, p < 0.001). The addition of staff training meant that the improvement in goal quality, which was only a trend at Time 2, was statistically significant at Time 3 (χ(2) 15.0, p ≤ 001). The training also led to a further significant increase in the framing and structuring of goals over the electronic goals system (χ(2) 11.5, 12.5, respectively, p ≤ 0.001). An electronic goals system combined with staff training improved the quality, rating, framing and structure of goal statements. © The Author(s) 2014.

  2. 19 CFR 192.14 - Electronic information for outward cargo required in advance of departure.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... Specifically, to effect the advance electronic transmission of the required cargo information to CBP, the USPPI... two hours prior to the arrival of the train at the border. (2) Applicability of time frames. The time... compliance with the time frames provided in paragraph (b)(1) of this section. Requirements placed on exports...

  3. High-speed cinematography of muscle contraction.

    PubMed

    HAUPT, R E; WALL, D M

    1962-07-13

    Motion pictures of the "twitch" of an excised frog gastrocnemius muscle taken at rates of 6000 frames per second provide a means of very accurately timing the phases. The extreme "slow motion" reveals surface phenomena not observable by other techniques. Evidence of "active relaxation" is suggested by results of frame-by-frame analysis.

  4. Decisions, decisions: analysis of age, cohort, and time of testing on framing of risky decision options.

    PubMed

    Mayhorn, Christopher B; Fisk, Arthur D; Whittle, Justin D

    2002-01-01

    Decision making in uncertain environments is a daily challenge faced by adults of all ages. Framing decision options as either gains or losses is a common method of altering decision-making behavior. In the experiment reported here, benchmark decision-making data collected in the 1970s by Tversky and Kahneman (1981, 1988) were compared with data collected from current samples of young and older adults to determine whether behavior was consistent across time. Although differences did emerge between the benchmark and the present samples, the effect of framing on decision behavior was relatively stable. The present findings suggest that adults of all ages are susceptible to framing effects. Results also indicated that apparent age differences might be better explained by an analysis of cohort and time-of-testing effects. Actual or potential applications of this research include an understanding of how framing might influence the decision-making behavior of people of all ages in a number of applied contexts, such as product warning interactions and medical decision scenarios.

  5. Rapid convergence of optimal control in NMR using numerically-constructed toggling frames

    NASA Astrophysics Data System (ADS)

    Coote, Paul; Anklin, Clemens; Massefski, Walter; Wagner, Gerhard; Arthanari, Haribabu

    2017-08-01

    We present a numerical method for rapidly solving the Bloch equation for an arbitrary time-varying spin-1/2 Hamiltonian. The method relies on fast, vectorized computations such as summation and quaternion multiplication, rather than slow computations such as matrix exponentiation. A toggling frame is constructed in which the Hamiltonian is time-invariant, and therefore has a simple analytical solution. The key insight is that constructing this frame is faster than solving the system dynamics in the original frame. Rapidly solving the Bloch equations for an arbitrary Hamiltonian is particularly useful in the context of NMR optimal control. Optimal control theory can be used to design pulse shapes for a range of tasks in NMR spectroscopy. However, it requires multiple simulations of the Bloch equations at each stage of the algorithm, and for each relevant set of parameters (e.g. chemical shift frequencies). This is typically time consuming. We demonstrate that by working in an appropriate toggling frame, optimal control pulses can be generated much faster. We present a new alternative to the well-known GRAPE algorithm to continuously update the toggling-frame as the optimal pulse is generated, and demonstrate that this approach is extremely fast. The use and benefit of rapid optimal pulse generation is demonstrated for 19F fragment screening experiments.

  6. Frame Rate Considerations for Real-Time Abdominal Acoustic Radiation Force Impulse Imaging

    PubMed Central

    Fahey, Brian J.; Palmeri, Mark L.; Trahey, Gregg E.

    2008-01-01

    With the advent of real-time Acoustic Radiation Force Impulse (ARFI) imaging, elevated frame rates are both desirable and relevant from a clinical perspective. However, fundamental limitations on frame rates are imposed by thermal safety concerns related to incident radiation force pulses. Abdominal ARFI imaging utilizes a curvilinear scanning geometry that results in markedly different tissue heating patterns than those previously studied for linear arrays or mechanically-translated concave transducers. Finite Element Method (FEM) models were used to simulate these tissue heating patterns and to analyze the impact of tissue heating on frame rates available for abdominal ARFI imaging. A perfusion model was implemented to account for cooling effects due to blood flow and frame rate limitations were evaluated in the presence of normal, reduced and negligible tissue perfusions. Conventional ARFI acquisition techniques were also compared to ARFI imaging with parallel receive tracking in terms of thermal efficiency. Additionally, thermocouple measurements of transducer face temperature increases were acquired to assess the frame rate limitations imposed by cumulative heating of the imaging array. Frame rates sufficient for many abdominal imaging applications were found to be safely achievable utilizing available ARFI imaging techniques. PMID:17521042

  7. Multiple-frame IR photo-recorder KIT-3M

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roos, E; Wilkins, P; Nebeker, N

    2006-05-15

    This paper reports the experimental results of a high-speed multi-frame infrared camera which has been developed in Sarov at VNIIEF. Earlier [1] we discussed the possibility of creation of the multi-frame infrared radiation photo-recorder with framing frequency about 1 MHz. The basis of the photo-recorder is a semiconductor ionization camera [2, 3], which converts IR radiation of spectral range 1-10 micrometers into a visible image. Several sequential thermal images are registered by using the IR converter in conjunction with a multi-frame electron-optical camera. In the present report we discuss the performance characteristics of a prototype commercial 9-frame high-speed IR photo-recorder.more » The image converter records infrared images of thermal fields corresponding to temperatures ranging from 300 C to 2000 C with an exposure time of 1-20 {micro}s at a frame frequency up to 500 KHz. The IR-photo-recorder camera is useful for recording the time evolution of thermal fields in fast processes such as gas dynamics, ballistics, pulsed welding, thermal processing, automotive industry, aircraft construction, in pulsed-power electric experiments, and for the measurement of spatial mode characteristics of IR-laser radiation.« less

  8. Anesthetic drugs and onset of malignant hyperthermia.

    PubMed

    Visoiu, Mihaela; Young, Michael C; Wieland, Keith; Brandom, Barbara W

    2014-02-01

    The time between the beginning of anesthetic administration and recognition of the first sign of malignant hyperthermia (MH) (MH onset time) could differ among anesthetic drugs. We examined the time of the first signs of suspected MH, anesthetic drugs administered, subject age, and year of event in Adverse Metabolic/Musculoskeletal Reaction to Anesthesia reports in the North American Malignant Hyperthermia Registry. Inclusion criteria were judgment by the reporting clinician that the event was possible or fulminant MH, documentation of the time when anesthetic administration began, and the time when the first MH sign was noted. Descriptive statistics, Kruskal-Wallis analysis, and nonparametric correlation were used to assess the difference in MH onset times under different conditions. Four hundred seventy-seven cases met inclusion criteria; 58.5% were possible MH and 41.5% fulminant MH. Inhaled anesthetic and succinylcholine were given in 53.9% of cases, inhaled anesthetic only in 41.7%, and succinylcholine without inhaled anesthetics in 2.9%. No causative anesthetic drugs were reported in 7 MH cases. In 394 patients exposed to only 1 of the 4 inhaled anesthetics, without regard for subject age, MH onset time was shorter in the presence of halothane than any of the other anesthetics and shorter after succinylcholine in all anesthetics. If succinylcholine was not given, MH onset was shorter during sevoflurane anesthesia than during desflurane or isoflurane. In 322 cases, 1 rather than multiple first signs of MH were reported with masseter spasm as the earliest MH sign. In 339 cases in which masseter spasm was not reported, there was no difference in MH onset time with or without succinylcholine. In 146 cases in which masseter spasm was not reported and succinylcholine was not given, MH onset was shorter during halothane anesthesia, than during exposure to desflurane, or isoflurane. MH onset time during sevoflurane was shorter than during desflurane or isoflurane. MH was reported later in the course of anesthesia after 1998, when halothane and succinylcholine were less often reported. MH occurred after succinylcholine administration in the absence of inhaled anesthetics. We could not separate an effect of age from that of other variables. The onset of MH has been observed later during desflurane and isoflurane anesthesia than during exposure to sevoflurane. Since 1998, MH signs have more often appeared later, in the second or third hour of anesthesia, than they did before 1998.

  9. Call-to-balloon time dashboard in patients with ST-segment elevation myocardial infarction results in significant improvement in the logistic chain.

    PubMed

    Hermans, Maaike P J; Velders, Matthijs A; Smeekes, Martin; Drexhage, Olivier S; Hautvast, Raymond W M; Ytsma, Timon; Schalij, Martin J; Umans, Victor A W M

    2017-08-04

    Timely reperfusion with primary percutaneous coronary intervention (pPCI) in ST-segment elevation myocardial infarction (STEMI) patients is associated with superior clinical outcomes. Aiming to reduce ischaemic time, an innovative system for home-to-hospital (H2H) time monitoring was implemented, which enabled real-time evaluation of ischaemic time intervals, regular feedback and improvements in the logistic chain. The objective of this study was to assess the results after implementation of the H2H dashboard for monitoring and evaluation of ischaemic time in STEMI patients. Ischaemic time in STEMI patients transported by emergency medical services (EMS) and treated with pPCI in the Noordwest Ziekenhuis, Alkmaar before (2008-2009; n=495) and after the implementation of the H2H dashboard (2011-2014; n=441) was compared. Median time intervals were significantly shorter in the H2H group (door-to-balloon time 32 [IQR 25-43] vs. 40 [IQR 28-55] minutes, p-value <0.001, FMC-to-balloon time 62 [IQR 52-75] vs. 80 [IQR 67-103] minutes, p-value <0.001, and treatment delay 142 [IQR 103-221] vs. 159 [IQR 123-253] minutes, p-value <0.001). The H2H time dashboard was independently associated with shorter time delays. Real-time monitoring and feedback on time delay with the H2H dashboard improves the logistic chain in STEMI patients, resulting in shorter ischaemic time intervals.

  10. Temporal compressive imaging for video

    NASA Astrophysics Data System (ADS)

    Zhou, Qun; Zhang, Linxia; Ke, Jun

    2018-01-01

    In many situations, imagers are required to have higher imaging speed, such as gunpowder blasting analysis and observing high-speed biology phenomena. However, measuring high-speed video is a challenge to camera design, especially, in infrared spectrum. In this paper, we reconstruct a high-frame-rate video from compressive video measurements using temporal compressive imaging (TCI) with a temporal compression ratio T=8. This means that, 8 unique high-speed temporal frames will be obtained from a single compressive frame using a reconstruction algorithm. Equivalently, the video frame rates is increased by 8 times. Two methods, two-step iterative shrinkage/threshold (TwIST) algorithm and the Gaussian mixture model (GMM) method, are used for reconstruction. To reduce reconstruction time and memory usage, each frame of size 256×256 is divided into patches of size 8×8. The influence of different coded mask to reconstruction is discussed. The reconstruction qualities using TwIST and GMM are also compared.

  11. Compartmentalized self-replication under fast PCR cycling conditions yields Taq DNA polymerase mutants with increased DNA-binding affinity and blood resistance.

    PubMed

    Arezi, Bahram; McKinney, Nancy; Hansen, Connie; Cayouette, Michelle; Fox, Jeffrey; Chen, Keith; Lapira, Jennifer; Hamilton, Sarah; Hogrefe, Holly

    2014-01-01

    Faster-cycling PCR formulations, protocols, and instruments have been developed to address the need for increased throughput and shorter turn-around times for PCR-based assays. Although run times can be cut by up to 50%, shorter cycle times have been correlated with lower detection sensitivity and increased variability. To address these concerns, we applied Compartmentalized Self Replication (CSR) to evolve faster-cycling mutants of Taq DNA polymerase. After five rounds of selection using progressively shorter PCR extension times, individual mutations identified in the fastest-cycling clones were randomly combined using ligation-based multi-site mutagenesis. The best-performing combinatorial mutants exhibit 35- to 90-fold higher affinity (lower Kd ) for primed template and a moderate (2-fold) increase in extension rate compared to wild-type Taq. Further characterization revealed that CSR-selected mutations provide increased resistance to inhibitors, and most notably, enable direct amplification from up to 65% whole blood. We discuss the contribution of individual mutations to fast-cycling and blood-resistant phenotypes.

  12. Is da Vinci Xi Better than da Vinci Si in Robotic Rectal Cancer Surgery? Comparison of the 2 Generations of da Vinci Systems.

    PubMed

    Ozben, Volkan; Cengiz, Turgut B; Atasoy, Deniz; Bayraktar, Onur; Aghayeva, Afag; Erguner, Ilknur; Baca, Bilgi; Hamzaoglu, Ismail; Karahasanoglu, Tayfun

    2016-10-01

    We aimed to compare perioperative outcomes for procedures using the latest generation of da Vinci robot versus its previous version in rectal cancer surgery. Fifty-three patients undergoing robotic rectal cancer surgery between January 2010 and March 2015 were included. Patients were classified into 2 groups (Xi, n=28 vs. Si, n=25) and perioperative outcomes were analyzed. The groups had significant differences including operative procedure, hybrid technique and redocking (P>0.05). In univariate analysis, the Xi group had shorter console times (265.7 vs. 317.1 min, P=0.006) and total operative times (321.6 vs. 360.4 min, P=0.04) and higher number of lymph nodes harvested (27.5 vs. 17.0, P=0.008). In multivariate analysis, Xi robot was associated with a shorter console time (odds ratio: 0.09, P=0.004) with no significant differences regarding other outcomes. Both generations of da Vinci robot led to similar short-term outcomes in rectal cancer surgery, but the Xi robot allowed shorter console times.

  13. Description of the life stages of quill mite Mironovia lagopus sp. nov. (Acari: Syringophilidae) parasitizing the rock ptarmigan Lagopus muta (Phasianidae) from Iceland.

    PubMed

    Bochkov, Andre V; Skirnisson, Karl

    2011-03-01

    A new species of syringophilid mites, Mironovia lagopus sp. nov. (Acari: Syringophilidae) is described from feather quills of the rock ptarigman Lagopus muta (Montin) (Phasianidae) from Iceland. Females of this new species differ from the closely related Mironovia rouloul Skoracki and Sikora by setae d2, which are subequal or 1.1-1.2 times shorter than setae e2 (vs. d2 1.4-1.5 times longer than e2 in Mironovia rouloul) and by setae ag1, which are 1.3-1.5 times shorter than ag2 (vs. ag1 1.7-1.8 times shorter than ag2). The postembryonic stages of this new species are figured and described in details. In ontogeny of Mironovia spp., the observed pattern of setal appearance is not different from the pattern in other galliform-associated genera such as Syringophilus and Colinophilus, with exception for tarsal setae p'I, II which are absent in protonymphs. The key to all four species of the genus Mironovia is also provided.

  14. Kepler Fine Guidance Sensor Data

    NASA Technical Reports Server (NTRS)

    Van Cleve, Jeffrey; Campbell, Jennifer Roseanna

    2017-01-01

    The Kepler and K2 missions collected Fine Guidance Sensor (FGS) data in addition to the science data, as discussed in the Kepler Instrument Handbook (KIH, Van Cleve and Caldwell 2016). The FGS CCDs are frame transfer devices (KIH Table 7) located in the corners of the Kepler focal plane (KIH Figure 24), which are read out 10 times every second. The FGS data are being made available to the user community for scientific analysis as flux and centroid time series, along with a limited number of FGS full frame images which may be useful for constructing a World Coordinate System (WCS) or otherwise putting the time series data in context. This document will describe the data content and file format, and give example MATLAB scripts to read the time series. There are three file types delivered as the FGS data.1. Flux and Centroid (FLC) data: time series of star signal and centroid data. 2. Ancillary FGS Reference (AFR) data: catalog of information about the observed stars in the FLC data. 3. FGS Full-Frame Image (FGI) data: full-frame image snapshots of the FGS CCDs.

  15. Celestial reference frames and the gauge freedom in the post-Newtonian mechanics of the Earth-Moon system

    NASA Astrophysics Data System (ADS)

    Kopeikin, Sergei; Xie, Yi

    2010-11-01

    We introduce the Jacobi coordinates adopted to the advanced theoretical analysis of the relativistic Celestial Mechanics of the Earth-Moon system. Theoretical derivation utilizes the relativistic resolutions on reference frames adopted by the International Astronomical Union (IAU) in 2000. The resolutions assume that the Solar System is isolated and space-time is asymptotically flat at infinity and the primary reference frame covers the entire space-time, has its origin at the Solar System barycenter (SSB) with spatial axes stretching up to infinity. The SSB frame is not rotating with respect to a set of distant quasars that are assumed to be at rest on the sky forming the International Celestial Reference Frame (ICRF). The second reference frame has its origin at the Earth-Moon barycenter (EMB). The EMB frame is locally inertial and is not rotating dynamically in the sense that equation of motion of a test particle moving with respect to the EMB frame, does not contain the Coriolis and centripetal forces. Two other local frames—geocentric and selenocentric—have their origins at the center of mass of Earth and Moon respectively and do not rotate dynamically. Each local frame is subject to the geodetic precession both with respect to other local frames and with respect to the ICRF because of their relative motion with respect to each other. Theoretical advantage of the dynamically non-rotating local frames is in a more simple mathematical description of the metric tensor and relative equations of motion of the Moon with respect to Earth. Each local frame can be converted to kinematically non-rotating one after alignment with the axes of ICRF by applying the matrix of the relativistic precession as recommended by the IAU resolutions. The set of one global and three local frames is introduced in order to decouple physical effects of gravity from the gauge-dependent effects in the equations of relative motion of the Moon with respect to Earth.

  16. Using Temporal Fill Factor to Reduce Frame Reconstruction Rates

    NASA Technical Reports Server (NTRS)

    Larimer, James; Balram, Nikhil; Gille, Jennifer; Luszcz, Jeffery

    1997-01-01

    The newer active matrix display technologies such as TFT-LCD, DMD, PDP maintain their pixel values through the entire frame time, presenting a 100% temporal fill factor, in contrast to the duty cycle produced by the phosphor impulse response of the CRT. This sample-and-hold characteristic can be exploited to lower the displayed frame rate without affecting visual quality. The lower frame rate results in significantly lower transmission bandwidth, power, and cost.

  17. The practical use of simplicity in developing ground water models

    USGS Publications Warehouse

    Hill, M.C.

    2006-01-01

    The advantages of starting with simple models and building complexity slowly can be significant in the development of ground water models. In many circumstances, simpler models are characterized by fewer defined parameters and shorter execution times. In this work, the number of parameters is used as the primary measure of simplicity and complexity; the advantages of shorter execution times also are considered. The ideas are presented in the context of constructing ground water models but are applicable to many fields. Simplicity first is put in perspective as part of the entire modeling process using 14 guidelines for effective model calibration. It is noted that neither very simple nor very complex models generally produce the most accurate predictions and that determining the appropriate level of complexity is an ill-defined process. It is suggested that a thorough evaluation of observation errors is essential to model development. Finally, specific ways are discussed to design useful ground water models that have fewer parameters and shorter execution times.

  18. Submillisecond X-ray photon correlation spectroscopy from a pixel array detector with fast dual gating and no readout dead-time

    DOE PAGES

    Zhang, Qingteng; Dufresne, Eric M.; Grybos, Pawel; ...

    2016-04-19

    Small-angle scattering X-ray photon correlation spectroscopy (XPCS) studies were performed using a novel photon-counting pixel array detector with dual counters for each pixel. Each counter can be read out independently from the other to ensure there is no readout dead-time between the neighboring frames. A maximum frame rate of 11.8 kHz was achieved. Results on test samples show good agreement with simple diffusion. Lastly, the potential of extending the time resolution of XPCS beyond the limit set by the detector frame rate using dual counters is also discussed.

  19. Submillisecond X-ray photon correlation spectroscopy from a pixel array detector with fast dual gating and no readout dead-time

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Qingteng; Dufresne, Eric M.; Grybos, Pawel

    Small-angle scattering X-ray photon correlation spectroscopy (XPCS) studies were performed using a novel photon-counting pixel array detector with dual counters for each pixel. Each counter can be read out independently from the other to ensure there is no readout dead-time between the neighboring frames. A maximum frame rate of 11.8 kHz was achieved. Results on test samples show good agreement with simple diffusion. Lastly, the potential of extending the time resolution of XPCS beyond the limit set by the detector frame rate using dual counters is also discussed.

  20. Population control of self-replicating systems

    NASA Technical Reports Server (NTRS)

    Mccord, R. L.

    1982-01-01

    The literature concerning fibonacci sequence and the mathematics of self replication are reviewed. One option allows each primary to generate n-replicas, one in each sequential time frame after its own generation with no restrictions on the number of ancestors per replica. The state vector of the replicas in an efficient manner is determined. Option-B has a fixed number of replicas per primary and no restrictions on the number of ancestors for a replica. Any element fij represents the number of elements of type-j in time frame k+1 generated from type-i in time frame k. Option-D is a diagonal matrix whose eigenvalues are precisely those of f.

  1. Submillisecond X-ray photon correlation spectroscopy from a pixel array detector with fast dual gating and no readout dead-time.

    PubMed

    Zhang, Qingteng; Dufresne, Eric M; Grybos, Pawel; Kmon, Piotr; Maj, Piotr; Narayanan, Suresh; Deptuch, Grzegorz W; Szczygiel, Robert; Sandy, Alec

    2016-05-01

    Small-angle scattering X-ray photon correlation spectroscopy (XPCS) studies were performed using a novel photon-counting pixel array detector with dual counters for each pixel. Each counter can be read out independently from the other to ensure there is no readout dead-time between the neighboring frames. A maximum frame rate of 11.8 kHz was achieved. Results on test samples show good agreement with simple diffusion. The potential of extending the time resolution of XPCS beyond the limit set by the detector frame rate using dual counters is also discussed.

  2. The effects of in-vehicle tasks and time-gap selection while reclaiming control from adaptive cruise control (ACC) with bus simulator.

    PubMed

    Lin, Tsang-Wei; Hwang, Sheue-Ling; Su, Jau-Ming; Chen, Wan-Hui

    2008-05-01

    This research aimed to find out the effects of in-vehicle distractions and time-gap settings with a fix-based bus driving simulator in a following scenario. Professional bus drivers were recruited to perform in-vehicle tasks while driving with adaptive cruise control (ACC) of changeable time-gap settings in freeway traffic. Thirty subjects were divided equally into three groups for different in-vehicle task modes (between subjects), including no task distraction, hands-free, and manual modes. Further, time-gap settings for the experimental ACC were: shorter than 1.0 s, 1.0-1.5 s, 1.5-2.0 s, and longer than 2.0 s (within subjects). Longitudinal (mean headway, forward collision rate, and response time) and lateral control (mean lateral lane position and its standard deviation) performance was assessed. In the results, longitudinal control performance was worsened by both shorter time-gaps and heavier in-vehicle tasks. But the interaction indicated that the harm by heavier in-vehicle distraction could be improved by longer time-gaps. As for the lateral control, it would only be negatively affected by shorter time-gap settings. This research indicates the effects of time-gaps and in-vehicle distraction, as well as the interaction. Proper time-gap selection under different in-vehicle distractions can help avoid accidents and keep safe.

  3. Human action recognition based on kinematic similarity in real time

    PubMed Central

    Chen, Longting; Luo, Ailing; Zhang, Sicong

    2017-01-01

    Human action recognition using 3D pose data has gained a growing interest in the field of computer robotic interfaces and pattern recognition since the availability of hardware to capture human pose. In this paper, we propose a fast, simple, and powerful method of human action recognition based on human kinematic similarity. The key to this method is that the action descriptor consists of joints position, angular velocity and angular acceleration, which can meet the different individual sizes and eliminate the complex normalization. The angular parameters of joints within a short sliding time window (approximately 5 frames) around the current frame are used to express each pose frame of human action sequence. Moreover, three modified KNN (k-nearest-neighbors algorithm) classifiers are employed in our method: one for achieving the confidence of every frame in the training step, one for estimating the frame label of each descriptor, and one for classifying actions. Additional estimating of the frame’s time label makes it possible to address single input frames. This approach can be used on difficult, unsegmented sequences. The proposed method is efficient and can be run in real time. The research shows that many public datasets are irregularly segmented, and a simple method is provided to regularize the datasets. The approach is tested on some challenging datasets such as MSR-Action3D, MSRDailyActivity3D, and UTD-MHAD. The results indicate our method achieves a higher accuracy. PMID:29073131

  4. Compressive Video Recovery Using Block Match Multi-Frame Motion Estimation Based on Single Pixel Cameras

    PubMed Central

    Bi, Sheng; Zeng, Xiao; Tang, Xin; Qin, Shujia; Lai, King Wai Chiu

    2016-01-01

    Compressive sensing (CS) theory has opened up new paths for the development of signal processing applications. Based on this theory, a novel single pixel camera architecture has been introduced to overcome the current limitations and challenges of traditional focal plane arrays. However, video quality based on this method is limited by existing acquisition and recovery methods, and the method also suffers from being time-consuming. In this paper, a multi-frame motion estimation algorithm is proposed in CS video to enhance the video quality. The proposed algorithm uses multiple frames to implement motion estimation. Experimental results show that using multi-frame motion estimation can improve the quality of recovered videos. To further reduce the motion estimation time, a block match algorithm is used to process motion estimation. Experiments demonstrate that using the block match algorithm can reduce motion estimation time by 30%. PMID:26950127

  5. Effect of axial length on laser spot size during photodynamic therapy: an experimental study in monkeys.

    PubMed

    Kondo, Mineo; Ito, Yasuki; Miyata, Kentaro; Kondo, Nagako; Ishikawa, Kohei; Terasaki, Hiroko

    2006-01-01

    To investigate the effect of shorter axial length on the laser spot size and laser energy during photodynamic therapy (PDT) in monkeys. Experimental study with four rhesus monkeys. PDT was performed on the normal retina of monkeys whose ocular axial lengths are shorter (19.55 to 20.25 mm) than that of humans. After the PDT, the eyes were enucleated, and the diameter of the irradiated laser spot was measured with a microcaliper. The area of actual laser spot was only 0.56 to 0.61 times of the planned area, which indicated that the laser energy/area was 1.64 to 1.78 times more intense than planned initially. These results are the in vivo demonstration that the diameter of PDT laser spot is smaller for eyes with shorter axial lengths.

  6. Assessment of second- and third-order ionospheric effects on regional networks: case study in China with longer CMONOC GPS coordinate time series

    NASA Astrophysics Data System (ADS)

    Deng, Liansheng; Jiang, Weiping; Li, Zhao; Chen, Hua; Wang, Kaihua; Ma, Yifang

    2017-02-01

    Higher-order ionospheric (HOI) delays are one of the principal technique-specific error sources in precise global positioning system analysis and have been proposed to become a standard part of precise GPS data processing. In this research, we apply HOI delay corrections to the Crustal Movement Observation Network of China's (CMONOC) data processing (from January 2000 to December 2013) and furnish quantitative results for the effects of HOI on CMONOC coordinate time series. The results for both a regional reference frame and global reference frame are analyzed and compared to clarify the HOI effects on the CMONOC network. We find that HOI corrections can effectively reduce the semi-annual signals in the northern and vertical components. For sites with lower semi-annual amplitudes, the average decrease in magnitude can reach 30 and 10 % for the northern and vertical components, respectively. The noise amplitudes with HOI corrections and those without HOI corrections are not significantly different. Generally, the HOI effects on CMONOC networks in a global reference frame are less obvious than the results in the regional reference frame, probably because the HOI-induced errors are smaller in comparison to the higher noise levels seen when using a global reference frame. Furthermore, we investigate the combined contributions of environmental loading and HOI effects on the CMONOC stations. The largest loading effects on the vertical displacement are found in the mid- to high-latitude areas. The weighted root mean square differences between the corrected and original weekly GPS height time series of the loading model indicate that the mass loading adequately reduced the scatter on the CMONOC height time series, whereas the results in the global reference frame showed better agreements between the GPS coordinate time series and the environmental loading. When combining the effects of environmental loading and HOI corrections, the results with the HOI corrections reduced the scatter on the observed GPS height coordinates better than the height when estimated without HOI corrections, and the combined solutions in the regional reference frame indicate more preferred improvements. Therefore, regional reference frames are recommended to investigate the HOI effects on regional networks.

  7. LCFM - LIVING COLOR FRAME MAKER: PC GRAPHICS GENERATION AND MANAGEMENT TOOL FOR REAL-TIME APPLICATIONS

    NASA Technical Reports Server (NTRS)

    Truong, L. V.

    1994-01-01

    Computer graphics are often applied for better understanding and interpretation of data under observation. These graphics become more complicated when animation is required during "run-time", as found in many typical modern artificial intelligence and expert systems. Living Color Frame Maker is a solution to many of these real-time graphics problems. Living Color Frame Maker (LCFM) is a graphics generation and management tool for IBM or IBM compatible personal computers. To eliminate graphics programming, the graphic designer can use LCFM to generate computer graphics frames. The graphical frames are then saved as text files, in a readable and disclosed format, which can be easily accessed and manipulated by user programs for a wide range of "real-time" visual information applications. For example, LCFM can be implemented in a frame-based expert system for visual aids in management of systems. For monitoring, diagnosis, and/or controlling purposes, circuit or systems diagrams can be brought to "life" by using designated video colors and intensities to symbolize the status of hardware components (via real-time feedback from sensors). Thus status of the system itself can be displayed. The Living Color Frame Maker is user friendly with graphical interfaces, and provides on-line help instructions. All options are executed using mouse commands and are displayed on a single menu for fast and easy operation. LCFM is written in C++ using the Borland C++ 2.0 compiler for IBM PC series computers and compatible computers running MS-DOS. The program requires a mouse and an EGA/VGA display. A minimum of 77K of RAM is also required for execution. The documentation is provided in electronic form on the distribution medium in WordPerfect format. A sample MS-DOS executable is provided on the distribution medium. The standard distribution medium for this program is one 5.25 inch 360K MS-DOS format diskette. The contents of the diskette are compressed using the PKWARE archiving tools. The utility to unarchive the files, PKUNZIP.EXE, is included. The Living Color Frame Maker tool was developed in 1992.

  8. Personality Disorder Symptom Severity Predicts Onset of Mood Episodes and Conversion to Bipolar I Disorder in Individuals with Bipolar Spectrum Disorder

    PubMed Central

    Ng, Tommy H.; Burke, Taylor A.; Stange, Jonathan P.; Walshaw, Patricia D.; Weiss, Rachel B.; Urosevic, Snezana; Abramson, Lyn Y.; Alloy, Lauren B.

    2017-01-01

    Although personality disorders (PDs) are highly comorbid with bipolar spectrum disorders (BSDs), little longitudinal research has been conducted to examine the prospective impact of PD symptoms on the course of BSDs. The aim of this study is to examine whether PD symptom severity predicts shorter time to onset of bipolar mood episodes and conversion to bipolar I disorder over time among individuals with less severe BSDs. Participants (n = 166) with bipolar II disorder, cyclothymia, or bipolar disorder not otherwise specified completed diagnostic interview assessments of PD symptoms and self-report measures of mood symptoms at baseline. They were followed prospectively with diagnostic interviews every four months for an average of 3.02 years. Cox proportional hazard regression analyses indicated that overall PD symptom severity significantly predicted shorter time to onset of hypomanic (hazard ratio [HR]= 1.42; p < .001) and major depressive episodes (HR = 1.51; p < .001) and conversion to bipolar I disorder (HR = 2.51; p < .001), after controlling for mood symptoms. Results also suggested that cluster B severity predicted shorter time to onset of hypomanic episodes (HR = 1.38; p = .002) and major depressive episodes (HR = 1.35; p = .01) and conversion to bipolar I disorder (HR = 2.77; p < .001), whereas cluster C severity (HR= 1.56; p < .001) predicted shorter time to onset of major depressive episodes. These results support predisposition models in suggesting that PD symptoms may act as a risk factor for a more severe course of BSDs. PMID:28368159

  9. Personality disorder symptom severity predicts onset of mood episodes and conversion to bipolar I disorder in individuals with bipolar spectrum disorder.

    PubMed

    Ng, Tommy H; Burke, Taylor A; Stange, Jonathan P; Walshaw, Patricia D; Weiss, Rachel B; Urosevic, Snezana; Abramson, Lyn Y; Alloy, Lauren B

    2017-04-01

    Although personality disorders (PDs) are highly comorbid with bipolar spectrum disorders (BSDs), little longitudinal research has been conducted to examine the prospective impact of PD symptoms on the course of BSDs. The aim of this study is to examine whether PD symptom severity predicts shorter time to onset of bipolar mood episodes and conversion to bipolar I disorder over time among individuals with less severe BSDs. Participants (n = 166) with bipolar II disorder, cyclothymia, or bipolar disorder not otherwise specified completed diagnostic interview assessments of PD symptoms and self-report measures of mood symptoms at baseline. They were followed prospectively with diagnostic interviews every 4 months for an average of 3.02 years. Cox proportional hazard regression analyses indicated that overall PD symptom severity significantly predicted shorter time to onset of hypomanic (hazard ratio [HR] = 1.42; p < .001) and major depressive episodes (HR = 1.51; p < .001) and conversion to bipolar I disorder (HR = 2.51; p < .001), after controlling for mood symptoms. Results also suggested that cluster B severity predicted shorter time to onset of hypomanic episodes (HR = 1.38; p = .002) and major depressive episodes (HR = 1.35; p = .01) and conversion to bipolar I disorder (HR = 2.77; p < .001), whereas cluster C severity (HR = 1.56; p < .001) predicted shorter time to onset of major depressive episodes. These results support predisposition models in suggesting that PD symptoms may act as a risk factor for a more severe course of BSDs. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  10. Pessimistic orientation in relation to telomere length in older men: the VA Normative Aging Study

    PubMed Central

    Ikeda, Ai; Schwartz, Joel; Peters, Junenette L.; Baccarelli, Andrea A.; Hoxha, Mirjam; Dioni, Laura; Spiro, Avron; Sparrow, David; Vokonas, Pantel; Kubzansky, Laura D.

    2014-01-01

    Background Recent research suggests pessimistic orientation is associated with shorter leukocyte telomere length (LTL). However, this is the first study to look not only at effects of pessimistic orientation on average LTL at multiple time points, but also at effects on the rate of change in LTL over time. Methods Participants were older men from the VA Normative Aging Study (n=490). The Life Orientation Test (LOT) was used to measure optimistic and pessimistic orientations at study baseline, and relative LTL by telomere to single copy gene ratio (T:S ratio) was obtained repeatedly over the course of the study (1999-2008). A total of 1,010 observations were included in the analysis. Linear mixed effect models with a random subject intercept were used to estimate associations. Results Higher pessimistic orientation scores were associated with shorter average LTL (percent difference by 1-SD increase in pessimistic orientation (95% CI): -3.08 (-5.62, -0.46)), and the finding was maintained after adjusting for the higher likelihood that healthier individuals return for follow-up visits (-3.44 (-5.95,-0.86)). However, pessimistic orientation scores were not associated with rate of change in LTL over time. No associations were found between overall optimism and optimistic orientation subscale scores and LTL. Conclusion Higher pessimistic orientation scores were associated with shorter LTL in older men. While there was no evidence that pessimistic orientation was associated with rate of change in LTL over time, higher levels of pessimistic orientation were associated with shorter LTL at baseline and this association persisted over time. PMID:24636503

  11. A systematic review and meta-analysis of quantitative interviewing tools to investigate self-reported HIV and STI associated behaviours in low- and middle-income countries.

    PubMed

    Phillips, Anna E; Gomez, Gabriella B; Boily, Marie-Claude; Garnett, Geoffrey P

    2010-12-01

    Studies identifying risks and evaluating interventions for human immunodeficiency virus (HIV) and other sexually transmitted infections often rely on self-reported measures of sensitive behaviours. Such self-reports can be subject to social desirability bias. Concerns over the accuracy of these measures have prompted efforts to improve the level of privacy and anonymity of the interview setting. This study aims to determine whether such novel tools minimize misreporting of sensitive information. Systematic review and meta-analysis of studies in low- and middle-income countries comparing traditional face-to-face interview (FTFI) with innovative tools for reporting HIV risk behaviour. Crude odds ratios (ORs) and 95% confidence intervals (CIs) were calculated. Cochran's chi-squared test of heterogeneity was performed to explore differences between estimates. Pooled estimates were determined by gender, region, education, setting and question time frame using a random effects model. We found and included 15 data sets in the meta-analysis. Most studies compared audio computer-assisted self interview (ACASI) with FTFI. There was significant heterogeneity across studies for three outcomes of interest: 'ever had sex' (I(2) = 93.4%, P < 0.001), non-condom use (I(2) = 89.3%, P < 0.001), and number of partners (I(2) = 75.3%, P < 0.001). For the fourth outcome, 'forced sex', there was homogenous increased reporting by non-FTFI methods (OR 1.47; 95% CI 1.11-1.94). Overall, non-FTFI methods were not consistently associated with a significant increase in the reporting of all outcomes. However, there was increased reporting associated with non-FTFI with region (Asia), setting (urban), education (>60% had secondary education) and a shorter question time frame. Contrary to expectation, differences between FTFI and non-interviewer-administered interview methods for the reported sensitive behaviour investigated were not uniform. However, we observed trends and variations in the level of reporting according to the outcome, study and population characteristics. FTFI may not always be inferior to innovative interview tools depending on the sensitivity of the question as well as the population assessed.

  12. Controlling the Display of Capsule Endoscopy Video for Diagnostic Assistance

    NASA Astrophysics Data System (ADS)

    Vu, Hai; Echigo, Tomio; Sagawa, Ryusuke; Yagi, Keiko; Shiba, Masatsugu; Higuchi, Kazuhide; Arakawa, Tetsuo; Yagi, Yasushi

    Interpretations by physicians of capsule endoscopy image sequences captured over periods of 7-8 hours usually require 45 to 120 minutes of extreme concentration. This paper describes a novel method to reduce diagnostic time by automatically controlling the display frame rate. Unlike existing techniques, this method displays original images with no skipping of frames. The sequence can be played at a high frame rate in stable regions to save time. Then, in regions with rough changes, the speed is decreased to more conveniently ascertain suspicious findings. To realize such a system, cue information about the disparity of consecutive frames, including color similarity and motion displacements is extracted. A decision tree utilizes these features to classify the states of the image acquisitions. For each classified state, the delay time between frames is calculated by parametric functions. A scheme selecting the optimal parameters set determined from assessments by physicians is deployed. Experiments involved clinical evaluations to investigate the effectiveness of this method compared to a standard-view using an existing system. Results from logged action based analysis show that compared with an existing system the proposed method reduced diagnostic time to around 32.5 ± minutes per full sequence while the number of abnormalities found was similar. As well, physicians needed less effort because of the systems efficient operability. The results of the evaluations should convince physicians that they can safely use this method and obtain reduced diagnostic times.

  13. Employment and work schedule are related to telomere length in women

    PubMed Central

    Parks, C G; DeRoo, L A; Miller, D B; McCanlies, E C; Cawthon, R M; Sandler, D P

    2011-01-01

    Objectives To examine the association of employment and work schedule with shorter DNA telomeres, a marker of cellular ageing and disease risk factor, and consider whether differences were related to health, behaviours and sociodemographic factors, or varied by stress levels or menopausal status. Methods This cross-sectional analysis of 608 women aged 35–74 in the Sister Study examined determinants of relative telomere length (rTL) measured by quantitative PCR in leucocyte DNA. Age-adjusted regression models estimated base pair (bp) rTL differences for current and lifetime schedule characteristics (ie, part-time, full-time or overtime hours; multiple jobs; irregular hours; shiftwork; work at night). Covariates included race, smoking, perceived stress, sleep, physical activity, health and menopausal status, education, marital status, live births, children under 18, measured body mass index and urinary stress hormones. Results Compared with non-employed women with moderate or substantial past work histories (n=190), those currently working full-time (n=247; median 40 h/week) had a shorter rTL, an age-adjusted difference of −329 bp (95% CI −110 to −548). Longer-duration full-time work was also associated with shorter rTL (age-adjusted difference of −472 bp, 95% CI −786 to −158 for 20+ vs 1–5 years). Findings were not explained by health and demographic covariates. However, rTL differences for working at least full-time were greater in women with higher stress and epinephrine levels. Conclusions Current and long-term full-time work were associated with shorter rTL, with differences of similar magnitude to smoking and history of heart disease or diabetes. Longitudinal data with specific stress measures are needed to further evaluate the impact of work schedule on rTL. PMID:21540175

  14. Employment and work schedule are related to telomere length in women.

    PubMed

    Parks, C G; DeRoo, L A; Miller, D B; McCanlies, E C; Cawthon, R M; Sandler, D P

    2011-08-01

    To examine the association of employment and work schedule with shorter DNA telomeres, a marker of cellular ageing and disease risk factor, and consider whether differences were related to health, behaviours and sociodemographic factors, or varied by stress levels or menopausal status. This cross-sectional analysis of 608 women aged 35-74 in the Sister Study examined determinants of relative telomere length (rTL) measured by quantitative PCR in leucocyte DNA. Age-adjusted regression models estimated base pair (bp) rTL differences for current and lifetime schedule characteristics (ie, part-time, full-time or overtime hours; multiple jobs; irregular hours; shiftwork; work at night). Covariates included race, smoking, perceived stress, sleep, physical activity, health and menopausal status, education, marital status, live births, children under 18, measured body mass index and urinary stress hormones. Compared with non-employed women with moderate or substantial past work histories (n=190), those currently working full-time (n=247; median 40 h/week) had a shorter rTL, an age-adjusted difference of -329 bp (95% CI -110 to -548). Longer-duration full-time work was also associated with shorter rTL (age-adjusted difference of -472 bp, 95% CI -786 to -158 for 20+ vs 1-5 years). Findings were not explained by health and demographic covariates. However, rTL differences for working at least full-time were greater in women with higher stress and epinephrine levels. Current and long-term full-time work were associated with shorter rTL, with differences of similar magnitude to smoking and history of heart disease or diabetes. Longitudinal data with specific stress measures are needed to further evaluate the impact of work schedule on rTL.

  15. Icon flickering, flicker rate, and color combinations of an icon's symbol/background in visual search performance.

    PubMed

    Huang, Kuo-Chen; Chiang, Shu-Ying; Chen, Chen-Fu

    2008-02-01

    The effects of color combinations of an icon's symbol/background and components of flicker and flicker rate on visual search performance on a liquid crystal display screen were investigated with 39 subjects who searched for a target icon in a circular stimulus array (diameter = 20 cm) including one target and 19 distractors. Analysis showed that the icon's symbol/background color significantly affected search time. The search times for icons with black/red and white/blue were significantly shorter than for white/yellow, black/yellow, and black/blue. Flickering of different components of the icon significantly affected the search time. Search time for an icon's border flickering was shorter than for an icon symbol flickering; search for flicker rates of 3 and 5 Hz was shorter than that for 1 Hz. For icon's symbol/background color combinations, search error rate for black/blue was greater than for black/red and white/blue combinations, and the error rate for an icon's border flickering was lower than for an icon's symbol flickering. Interactions affected search time and error rate. Results are applicable to design of graphic user interfaces.

  16. Complementary frame reconstruction: a low-biased dynamic PET technique for low count density data in projection space

    NASA Astrophysics Data System (ADS)

    Hong, Inki; Cho, Sanghee; Michel, Christian J.; Casey, Michael E.; Schaefferkoetter, Joshua D.

    2014-09-01

    A new data handling method is presented for improving the image noise distribution and reducing bias when reconstructing very short frames from low count dynamic PET acquisition. The new method termed ‘Complementary Frame Reconstruction’ (CFR) involves the indirect formation of a count-limited emission image in a short frame through subtraction of two frames with longer acquisition time, where the short time frame data is excluded from the second long frame data before the reconstruction. This approach can be regarded as an alternative to the AML algorithm recently proposed by Nuyts et al, as a method to reduce the bias for the maximum likelihood expectation maximization (MLEM) reconstruction of count limited data. CFR uses long scan emission data to stabilize the reconstruction and avoids modification of algorithms such as MLEM. The subtraction between two long frame images, naturally allows negative voxel values and significantly reduces bias introduced in the final image. Simulations based on phantom and clinical data were used to evaluate the accuracy of the reconstructed images to represent the true activity distribution. Applicability to determine the arterial input function in human and small animal studies is also explored. In situations with limited count rate, e.g. pediatric applications, gated abdominal, cardiac studies, etc., or when using limited doses of short-lived isotopes such as 15O-water, the proposed method will likely be preferred over independent frame reconstruction to address bias and noise issues.

  17. Slow speed—fast motion: time-lapse recordings in physics education

    NASA Astrophysics Data System (ADS)

    Vollmer, Michael; Möllmann, Klaus-Peter

    2018-05-01

    Video analysis with a 30 Hz frame rate is the standard tool in physics education. The development of affordable high-speed-cameras has extended the capabilities of the tool for much smaller time scales to the 1 ms range, using frame rates of typically up to 1000 frames s-1, allowing us to study transient physics phenomena happening too fast for the naked eye. Here we want to extend the range of phenomena which may be studied by video analysis in the opposite direction by focusing on much longer time scales ranging from minutes, hours to many days or even months. We discuss this time-lapse method, needed equipment and give a few hints of how to produce respective recordings for two specific experiments.

  18. Validity and reproducibility of self-reported working hours among Japanese male employees.

    PubMed

    Imai, Teppei; Kuwahara, Keisuke; Miyamoto, Toshiaki; Okazaki, Hiroko; Nishihara, Akiko; Kabe, Isamu; Mizoue, Tetsuya; Dohi, Seitaro

    2016-07-22

    Working long hours is a potential health hazard. Although self-reporting of working hours in various time frames has been used in epidemiologic studies, its validity is unclear. The objective of this study was to examine the validity and reproducibility of self-reported working hours among Japanese male employees. The participants were 164 male employees of four large-scale companies in Japan. For validity, the Spearman correlation between self-reported working hours in the second survey and the working hours recorded by the company was calculated for the following four time frames: daily working hours, monthly overtime working hours in the last month, average overtime working hours in the last 3 months, and the frequency of long working months (≥45 h/month) within the last 12 months. For reproducibility, the intraclass correlation between the first (September 2013) and second surveys (December 2013) was calculated for each of the four time frames. The Spearman correlations between self-reported working hours and those based on company records were 0.74, 0.81, 0.85, and 0.89 for daily, monthly, 3-monthly, and yearly time periods, respectively. The intraclass correlations for self-reported working hours between the two questionnaire surveys were 0.63, 0.66, 0.73, and 0.87 for the respective time frames. The results of the present study among Japanese male employees suggest that the validity of self-reported working hours is high for all four time frames, whereas the reproducibility is moderate to high.

  19. A potential means of improving the evaluation of deformity corrections with Taylor spatial frames over time by using volumetric imaging: preliminary results.

    PubMed

    Starr, Vanessa; Olivecrona, H; Noz, M E; Maguire, G Q; Zeleznik, M P; Jannsson, Karl-åke

    2009-01-01

    In this study we explore the possibility of accurately and cost-effectively monitoring tibial deformation induced by Taylor Spatial Frames (TSFs), using time-separated computed tomography (CT) scans and a volume fusion technique to determine tibial rotation and translation. Serial CT examinations (designated CT-A and CT-B, separated by a time interval of several months) of two patients were investigated using a previously described and validated volume fusion technique, in which user-defined landmarks drive the 3D registration of the two CT volumes. Both patients had undergone dual osteotomies to correct for tibial length and rotational deformity. For each registration, 10 or more landmarks were selected, and the quality of the fused volume was assessed both quantitatively and via 2D and 3D visualization tools. First, the proximal frame segment and tibia in CT-A and CT-B were brought into alignment (registered) by selecting landmarks on the frame and/or tibia. In the resulting "fused" volume, the proximal frame segment and tibia from CT-A and CT-B were aligned, while the distal frame segment and tibia from CT-A and CT-B were likely not aligned as a result of tibial deformation or frame adjustment having occurred between the CT scans. Using the proximal fused volume, the distal frame segment and tibia were then registered by selecting landmarks on the frame and/or tibia. The difference between the centroids of the final distal landmarks was used to evaluate the lengthening of the tibia, and the Euler angles from the registration were used to evaluate the rotation. Both the frame and bone could be effectively registered (based on visual interpretation). Movement between the proximal frame and proximal bone could be visualized in both cases. The spatial effect on the tibia could be both visually assessed and measured: 34 mm, 10 degrees in one case; 5 mm, 1 degrees in the other. This retrospective analysis of spatial correction of the tibia using Taylor Spatial Frames shows that CT offers an interesting potential means of quantitatively monitoring the patient's treatment. Compared with traditional techniques, modern CT scans in conjunction with image processing provide a high-resolution, spatially correct, and three-dimensional measurement system which can be used to quickly and easily assess the patient's treatment at low cost to the patient and hospital.

  20. An Initial Investigation into Naturally Occurring Loss- and Gain-Framed Memorable Breast Cancer Messages

    PubMed Central

    LaPlante, Carolyn; Smith, Sandi; Kotowski, Michael; Nazione, Samantha; Stohl, Cynthia; Prestin, Abby; So, Jiyeon; Nabi, Robin

    2012-01-01

    Memorable message research examines interpersonal messages “…remembered for extremely long periods of time and which people perceive as a major influence on the course of their lives” (Knapp, Stohl, & Reardon, 1981, p. 27). They can also guide actions, such as health behaviors. This exploratory research examined self-reported memorable messages about breast cancer to determine if they were framed, emphasizing either the benefits (gain-framed) or the costs (loss-framed) of a behavior. About one-fourth of the messages were framed, with most being gain-framed. The messages tended to emphasize early detection actions. Study limitations and implications for future research are discussed. PMID:22539867

  1. From Game Protection to Wildlife Management: Frame Shifts, Organizational Development, and Field Practices

    ERIC Educational Resources Information Center

    Brulle, Robert J.; Benford, Robert D.

    2012-01-01

    One enduring question in social movements research is the relationship between cultural representations and organizational structure. In this article, we examine the development of different discursive frames over time, and how such frame shifts affect movement structure and practices. This approach seeks to illuminate the dialectical interplay…

  2. Reframing Practice: High School Mathematics Teachers' Learning through Interactions in Their Workplace Community

    ERIC Educational Resources Information Center

    Bannister, Nicole A.

    2009-01-01

    This dissertation seeks to understand how teachers learn through interactions in newly formed workplace communities by examining how mathematics teachers engaged in equity-oriented reforms frame problems of practice. It examines how teachers' framings develop over time, and how teachers' shifting frames connect to their learning in a community of…

  3. 40 CFR 260.34 - Standards and criteria for non-waste determinations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reasonable time frame and ensure that the hazardous secondary material will not be abandoned (for example... statistical or from a health and environmental risk perspective than would otherwise be released by the... hazardous secondary material in a reasonable time frame and ensure that the hazardous secondary material...

  4. User's manual for SYNC: A FORTRAN program for merging and time-synchronizing data

    NASA Technical Reports Server (NTRS)

    Maine, R. E.

    1981-01-01

    The FORTRAN 77 computer program SYNC for merging and time synchronizing data is described. The program SYNC reads one or more input files which contain either synchronous data frames or time-tagged data points, which can be compressed. The program decompresses and time synchronizes the data, correcting for any channel time skews. Interpolation and hold last value synchronization algorithms are available. The output from SYNC is a file of time synchronized data frames at any requested sample rate.

  5. The effects of publishing emergency department wait time on patient utilization patterns in a community with two emergency department sites: a retrospective, quasi-experiment design.

    PubMed

    Xie, Bin; Youash, Sabrina

    2011-06-14

    Providing emergency department (ED) wait time information to the public has been suggested as a mechanism to reduce lengthy ED wait times (by enabling patients to select the ED site with shorter wait time), but the effects of such a program have not been evaluated. We evaluated the effects of such a program in a community with two ED sites. Descriptive statistics for wait times of the two sites before and after the publication of wait time information were used to evaluate the effects of the publication of wait time information on wait times. Multivariate logistical regression was used to test whether or not individual patients used published wait time to decide which site to visit. We found that the rates of wait times exceeding 4 h, and the 95th percentile of wait times in the two sites decreased after the publication of wait time information, even though the average wait times experienced a slight increase. We also found that after controlling for other factors, the site with shorter wait time had a higher likelihood of being selected after the publication of wait time information, but there was no such relationship before the publication. These findings were consistent with the hypothesis that the publication of wait time information leads to patients selecting the site with shorter wait time. While publishing ED wait time information did not improve average wait time, it reduced the rates of lengthy wait times.

  6. Challenges and Opportunities for a Human Rights Frame in South Korea: Context and Strategizing in the Anti-Domestic Violence Movement.

    PubMed

    Heo, Min Sook; Rakowski, Cathy A

    2014-05-01

    Korean feminists are keenly aware that transnational feminists emphasize a human rights framework to eradicate violence against women. But in the 1990s, they based their anti-domestic violence campaign on a frame of "preservation of the family" because it was more culturally resonant at the time than a human rights frame. The results include passage of two legislative Acts, failure to implement as intended, and a continued search for a more effective frame. Ironically, the human rights frame has re-emerged as a possible solution. © The Author(s) 2014.

  7. As time passes by: Observed motion-speed and psychological time during video playback.

    PubMed

    Nyman, Thomas Jonathan; Karlsson, Eric Per Anders; Antfolk, Jan

    2017-01-01

    Research shows that psychological time (i.e., the subjective experience and assessment of the passage of time) is malleable and that the central nervous system re-calibrates temporal information in accordance with situational factors so that psychological time flows slower or faster. Observed motion-speed (e.g., the visual perception of a rolling ball) is an important situational factor which influences the production of time estimates. The present study examines previous findings showing that observed slow and fast motion-speed during video playback respectively results in over- and underproductions of intervals of time. Here, we investigated through three separate experiments: a) the main effect of observed motion-speed during video playback on a time production task and b) the interactive effect of the frame rate (frames per second; fps) and motion-speed during video playback on a time production task. No main effect of video playback-speed or interactive effect between video playback-speed and frame rate was found on time production.

  8. As time passes by: Observed motion-speed and psychological time during video playback

    PubMed Central

    Karlsson, Eric Per Anders; Antfolk, Jan

    2017-01-01

    Research shows that psychological time (i.e., the subjective experience and assessment of the passage of time) is malleable and that the central nervous system re-calibrates temporal information in accordance with situational factors so that psychological time flows slower or faster. Observed motion-speed (e.g., the visual perception of a rolling ball) is an important situational factor which influences the production of time estimates. The present study examines previous findings showing that observed slow and fast motion-speed during video playback respectively results in over- and underproductions of intervals of time. Here, we investigated through three separate experiments: a) the main effect of observed motion-speed during video playback on a time production task and b) the interactive effect of the frame rate (frames per second; fps) and motion-speed during video playback on a time production task. No main effect of video playback-speed or interactive effect between video playback-speed and frame rate was found on time production. PMID:28614353

  9. Effects of message framing on self-report and accelerometer-assessed physical activity across age and gender groups.

    PubMed

    Li, Kin-Kit; Cheng, Sheung-Tak; Fung, Helene H

    2014-02-01

    This study compared message-framing effects on physical activity (PA) across age and gender groups. Participants included 111 younger and 100 older adults (68% were women), randomly assigned to read gain-framed or loss-framed PA messages in promotion pamphlets, and who wore accelerometers for the following 14 days. Using regression analyses controlling for demographic and health factors, we found significant age-by-gender-by-framing interactions predicting self-report (B = -4.39, p = .01) and accelerometer-assessed PA (B = -2.44, p = .02) during the follow-up period. Gain-framed messages were more effective than loss-framed messages in promoting PA behaviors only among older men. We speculated that the age-related positivity effect, as well as the age and gender differences in issue involvement, explained the group differences in framing. In addition, more time availability and higher self-efficacy among older men might have contributed to the results.

  10. FAST MODES AND DUSTY HORSESHOES IN TRANSITIONAL DISKS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mittal, Tushar; Chiang, Eugene

    The brightest transitional protoplanetary disks are often azimuthally asymmetric: their millimeter-wave thermal emission peaks strongly on one side. Dust overdensities can exceed ∼100:1, while gas densities vary by factors less than a few. We propose that these remarkable ALMA observations—which may bear on how planetesimals form—reflect a gravitational global mode in the gas disk. The mode is (1) fast—its pattern speed equals the disk's mean Keplerian frequency; (2) of azimuthal wavenumber m = 1, displacing the host star from the barycenter; and (3) Toomre-stable. We solve for gas streamlines including the indirect stellar potential in the frame rotating with themore » pattern speed, under the drastic simplification that gas does not feel its own gravity. Near corotation, the gas disk takes the form of a horseshoe-shaped annulus. Dust particles with aerodynamic stopping times much shorter or much longer than the orbital period are dragged by gas toward the horseshoe center. For intermediate stopping times, dust converges toward a ∼45° wide arc on the corotation circle. Particles that do not reach their final accumulation points within disk lifetimes, either because of gas turbulence or long particle drift times, conform to horseshoe-shaped gas streamlines. Our mode is not self-consistent because we neglect gas self-gravity; still, we expect that trends between accumulation location and particle size, similar to those we have found, are generically predicted by fast modes and are potentially observable. Unlike vortices, global modes are not restricted in radial width to the pressure scale height; their large radial and azimuthal extents may better match observations.« less

  11. INFLUENCE OF THE GALACTIC GRAVITATIONAL FIELD ON THE POSITIONAL ACCURACY OF EXTRAGALACTIC SOURCES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larchenkova, Tatiana I.; Lutovinov, Alexander A.; Lyskova, Natalya S.

    We investigate the influence of random variations of the Galactic gravitational field on the apparent celestial positions of extragalactic sources. The basic statistical characteristics of a stochastic process (first-order moments, an autocorrelation function and a power spectral density) are used to describe a light ray deflection in a gravitational field of randomly moving point masses as a function of the source coordinates. We map a 2D distribution of the standard deviation of the angular shifts in positions of distant sources (including reference sources of the International Celestial Reference Frame) with respect to their true positions. For different Galactic matter distributionsmore » the standard deviation of the offset angle can reach several tens of μ as (microarcsecond) toward the Galactic center, decreasing down to 4–6 μ as at high galactic latitudes. The conditional standard deviation (“jitter”) of 2.5 μ as is reached within 10 years at high galactic latitudes and within a few months toward the inner part of the Galaxy. The photometric microlensing events are not expected to be disturbed by astrometric random variations anywhere except the inner part of the Galaxy as the Einstein–Chvolson times are typically much shorter than the jittering timescale. While a jitter of a single reference source can be up to dozens of μ as over some reasonable observational time, using a sample of reference sources would reduce the error in relative astrometry. The obtained results can be used for estimating the physical upper limits on the time-dependent accuracy of astrometric measurements.« less

  12. Deformation history of Mauna Loa (Hawaii) from 2003 to 2014 through InSAR data: understanding the shorter-term processes

    NASA Astrophysics Data System (ADS)

    La Marra, Daniele; Poland, Michael P.; Acocella, Valerio; Battaglia, Maurizio; Miklius, Asta

    2016-04-01

    Geodesy allows detecting the deformation of volcanoes, thus understanding magmatic processes. This becomes particularly efficient when time series are available and volcanoes can be monitored on the mean-term (decades), and not only during a specific event. Here we exploit the SBAS technique, using SAR images from ENVISAT (descending and ascending orbits; 2003 - 2010) and COSMO-SkyMed (descending and ascending orbits; 2012 - 2014), to study a decade of deformation at Mauna Loa (Hawaii). These data are merged time series data from 24 continuously operating GPS stations, which allows us to calibrate the InSAR time series. Our results show a long-term inflation of the volcano from 2003 to 2014, reaching a peak of ~11 cm/yr on the summit area between mid-2004 to mid-2005 and then slowing down. Within this frame, we were able to identify five main periods with approximately linear deformation behavior. The inversion of the deformation data in the first four periods suggests the repeated, though not constant, intrusion of one or more dikes below the summit caldera and the upper Southwest Rift Zone. Moreover, the dike intrusion coincides with minor acceleration of flank slip. Such a behavior is distinctive and, with the exception of the nearby Kilauea, has not been observed at any other volcano on the mean term. It is proposed that continuous, even though not constant flank instability of the SE flank may promote semi-continuous intrusions in a volcano with a ready magma supply.

  13. Why Is There an Abrupt Transition from Solid Rock to Low Crystallinity Magma in Drilled Magma Bodies?

    NASA Astrophysics Data System (ADS)

    Eichelberger, J. C.; Carrigan, C. R.; Sun, Y.; Lavallée, Y.

    2017-12-01

    We report on a preliminary evaluation, from basic principles of heat and mass transfer, on the unexpectedly abrupt transition from cuttings of solid rock to fragments of crystal poor glass during drilling into magma bodies. Our analysis is based on conditions determined and inferred for the 2009 IDDP-1 well in Krafla Caldera, which entered apparently liquidus rhyolite magma at about 900oC at a depth of 2104 m. Simple conduction would predict some 30 m of crystallization and partial crystallization since the latest time the magma could have been intruded, approximately 30 years prior to discovery by drilling. Option 1: The expected crystallization of magma has occurred but interstitial melt remains. The pressure difference between lithostatic load of about 50 MPa on the mush and 20 MPa hydrostatic pressure in the well causes pore melt to flow from the permeable mush into the borehole, where it becomes the source of the quenched melt chips. To be viable, this mechanism must work over the time frame of a day. Option 2: The expected crystallization is occurring, but high Rayleigh number thermal convection in the magma chamber continuously displaces crystallizing roof magma by liquidus magma from the interior of the body. To be viable, this mechanism must result in overturning magma in the chamber on a time scale that is much shorter than that of crystallization. Option 3: Flow-induced crystal migration away from zones of high shear created during drilling into magma may preferentially produce low-crystal-content melt at the boundary of the borehole, which is then sampled.

  14. KALREF—A Kalman filter and time series approach to the International Terrestrial Reference Frame realization

    NASA Astrophysics Data System (ADS)

    Wu, Xiaoping; Abbondanza, Claudio; Altamimi, Zuheir; Chin, T. Mike; Collilieux, Xavier; Gross, Richard S.; Heflin, Michael B.; Jiang, Yan; Parker, Jay W.

    2015-05-01

    The current International Terrestrial Reference Frame is based on a piecewise linear site motion model and realized by reference epoch coordinates and velocities for a global set of stations. Although linear motions due to tectonic plates and glacial isostatic adjustment dominate geodetic signals, at today's millimeter precisions, nonlinear motions due to earthquakes, volcanic activities, ice mass losses, sea level rise, hydrological changes, and other processes become significant. Monitoring these (sometimes rapid) changes desires consistent and precise realization of the terrestrial reference frame (TRF) quasi-instantaneously. Here, we use a Kalman filter and smoother approach to combine time series from four space geodetic techniques to realize an experimental TRF through weekly time series of geocentric coordinates. In addition to secular, periodic, and stochastic components for station coordinates, the Kalman filter state variables also include daily Earth orientation parameters and transformation parameters from input data frames to the combined TRF. Local tie measurements among colocated stations are used at their known or nominal epochs of observation, with comotion constraints applied to almost all colocated stations. The filter/smoother approach unifies different geodetic time series in a single geocentric frame. Fragmented and multitechnique tracking records at colocation sites are bridged together to form longer and coherent motion time series. While the time series approach to TRF reflects the reality of a changing Earth more closely than the linear approximation model, the filter/smoother is computationally powerful and flexible to facilitate incorporation of other data types and more advanced characterization of stochastic behavior of geodetic time series.

  15. Real-time unmanned aircraft systems surveillance video mosaicking using GPU

    NASA Astrophysics Data System (ADS)

    Camargo, Aldo; Anderson, Kyle; Wang, Yi; Schultz, Richard R.; Fevig, Ronald A.

    2010-04-01

    Digital video mosaicking from Unmanned Aircraft Systems (UAS) is being used for many military and civilian applications, including surveillance, target recognition, border protection, forest fire monitoring, traffic control on highways, monitoring of transmission lines, among others. Additionally, NASA is using digital video mosaicking to explore the moon and planets such as Mars. In order to compute a "good" mosaic from video captured by a UAS, the algorithm must deal with motion blur, frame-to-frame jitter associated with an imperfectly stabilized platform, perspective changes as the camera tilts in flight, as well as a number of other factors. The most suitable algorithms use SIFT (Scale-Invariant Feature Transform) to detect the features consistent between video frames. Utilizing these features, the next step is to estimate the homography between two consecutives video frames, perform warping to properly register the image data, and finally blend the video frames resulting in a seamless video mosaick. All this processing takes a great deal of resources of resources from the CPU, so it is almost impossible to compute a real time video mosaic on a single processor. Modern graphics processing units (GPUs) offer computational performance that far exceeds current CPU technology, allowing for real-time operation. This paper presents the development of a GPU-accelerated digital video mosaicking implementation and compares it with CPU performance. Our tests are based on two sets of real video captured by a small UAS aircraft; one video comes from Infrared (IR) and Electro-Optical (EO) cameras. Our results show that we can obtain a speed-up of more than 50 times using GPU technology, so real-time operation at a video capture of 30 frames per second is feasible.

  16. Shorter Perceived Outpatient MRI Wait Times Associated With Higher Patient Satisfaction.

    PubMed

    Holbrook, Anna; Glenn, Harold; Mahmood, Rabia; Cai, Qingpo; Kang, Jian; Duszak, Richard

    2016-05-01

    The aim of this study was to assess differences in perceived versus actual wait times among patients undergoing outpatient MRI examinations and to correlate those times with patient satisfaction. Over 15 weeks, 190 patients presenting for outpatient MR in a radiology department in which "patient experience" is one of the stated strategic priorities were asked to (1) estimate their wait times for various stages in the imaging process and (2) state their satisfaction with their imaging experience. Perceived times were compared with actual electronic time stamps. Perceived and actual times were compared and correlated with standardized satisfaction scores using Kendall τ correlation. The mean actual wait time between patient arrival and examination start was 53.4 ± 33.8 min, whereas patients perceived a mean wait time of 27.8 ± 23.1 min, a statistically significant underestimation of 25.6 min (P < .001). Both shorter actual and perceived wait times at all points during patient encounters were correlated with higher satisfaction scores (P < .001). Patients undergoing outpatient MR examinations in an environment designed to optimize patient experience underestimated wait times at all points during their encounters. Shorter perceived and actual wait times were both correlated with higher satisfaction scores. As satisfaction surveys play a larger role in an environment of metric transparency and value-based payments, better understanding of such factors will be increasingly important. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  17. Pre-hospital electrocardiogram triage with telemedicine near halves time to treatment in STEMI: A meta-analysis and meta-regression analysis of non-randomized studies.

    PubMed

    Brunetti, Natale Daniele; De Gennaro, Luisa; Correale, Michele; Santoro, Francesco; Caldarola, Pasquale; Gaglione, Antonio; Di Biase, Matteo

    2017-04-01

    A shorter time to treatment has been shown to be associated with lower mortality rates in acute myocardial infarction (AMI). Several strategies have been adopted with the aim to reduce any delay in diagnosis of AMI: pre-hospital triage with telemedicine is one of such strategies. We therefore aimed to measure the real effect of pre-hospital triage with telemedicine in case of AMI in a meta-analysis study. We performed a meta-analysis of non-randomized studies with the aim to quantify the exact reduction of time to treatment achieved by pre-hospital triage with telemedicine. Data were pooled and compared by relative time reduction and 95% C.I.s. A meta-regression analysis was performed in order to find possible predictors of shorter time to treatment. Eleven studies were selected and finally evaluated in the study. The overall relative reduction of time to treatment with pre-hospital triage and telemedicine was -38/-40% (p<0.001). Absolute time reduction was significantly correlated to time to treatment in the control groups (p<0.001), while relative time reduction was independent. A non-significant trend toward shorter relative time reductions was observed over years. Pre-hospital triage with telemedicine is associated with a near halved time to treatment in AMI. The benefit is larger in terms of absolute time to treatment reduction in populations with larger delays to treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Framing alters risk-taking behavior on a modified Balloon Analogue Risk Task (BART) in a sex-specific manner.

    PubMed

    Gabriel, Kara I; Williamson, Ashley

    2010-12-01

    Framing uncertain scenarios to emphasize potential positive or negative elements influences decision making and behavior. The current experiment investigated sex differences in framing effects on risk-taking propensity in a modified version of the Balloon Analogue Risk Task (BART). Male and female undergraduates completed questionnaires on sensation seeking, impulsiveness, and risk and benefit perception prior to viewing one of three framing conditions for the BART: (1) positively-framed instructions emphasizing the ability to earn money if balloons were inflated to large size; (2) negatively framed instructions emphasizing the possibility that money could be lost if balloons were inflated to bursting; and (3) completely framed instructions noting both possible outcomes. Results revealed correlations between BART performance and impulsiveness for both sexes. Compared to positive and complete framing, negatively framed instructions decreased balloon inflation time in women but not men, indicating sex differences in response to treatments designed to alter risk-taking behavior.

  19. Reference frames, gauge transformations and gravitomagnetism in the post-Newtonian theory of the lunar motion

    NASA Astrophysics Data System (ADS)

    Xie, Yi; Kopeikin, Sergei

    2010-01-01

    We construct a set of reference frames for description of the orbital and rotational motion of the Moon. We use a scalar-tensor theory of gravity depending on two parameters of the parametrized post-Newtonian (PPN) formalism and utilize the concepts of the relativistic resolutions on reference frames adopted by the International Astronomical Union in 2000. We assume that the solar system is isolated and space-time is asymptotically flat. The primary reference frame has the origin at the solar-system barycenter (SSB) and spatial axes are going to infinity. The SSB frame is not rotating with respect to distant quasars. The secondary reference frame has the origin at the Earth-Moon barycenter (EMB). The EMB frame is local with its spatial axes spreading out to the orbits of Venus and Mars and not rotating dynamically in the sense that both the Coriolis and centripetal forces acting on a free-falling test particle, moving with respect to the EMB frame, are excluded. Two other local frames, the geocentric (GRF) and the selenocentric (SRF) frames, have the origin at the center of mass of the Earth and Moon respectively. They are both introduced in order to connect the coordinate description of the lunar motion, observer on the Earth, and a retro-reflector on the Moon to the observable quantities which are the proper time and the laser-ranging distance. We solve the gravity field equations and find the metric tensor and the scalar field in all frames. We also derive the post-Newtonian coordinate transformations between the frames and analyze the residual gauge freedom of the solutions of the field equations. We discuss the gravitomagnetic effects in the barycentric equations of the motion of the Moon and argue that they are beyond the current accuracy of lunar laser ranging (LLR) observations.

  20. Continuous Positive Airway Pressure Device Time to Procurement in a Disadvantaged Population.

    PubMed

    DelRosso, Lourdes M; Hoque, Romy; Chesson, Andrew L

    2015-01-01

    Introduction. The management of obstructive sleep apnea (OSA) in patients who cannot afford a continuous positive airway pressure (CPAP) device is challenging. In this study we compare time to CPAP procurement in three groups of patients diagnosed with OSA: uninsured subsidized by a humanitarian grant (Group 1), uninsured unsubsidized (Group 2), and those with Medicare or Medicaid (Group 3). We evaluate follow-up and adherence in Group 1. We hypothesize that additional factors, rather than just the ability to obtain CPAP, may uniquely affect follow-up and adherence in uninsured patients. Methods. 30 patients were in Groups 1 and 2, respectively. 12 patients were in Group 3. Time of CPAP procurement from OSA diagnosis to CPAP initiation was assessed in all groups. CPAP adherence data was collected for Group 1 patients at 1, 3, 6, and 9 months. Results. There were no significant differences between groups in gender, age, body mass index, or apnea hypopnea index. The mean time to procurement in Group 1 was shorter compared to Group 2 but not significant. Compared to both Group 1 and Group 2, Group 3 patients had significantly shorter times to device procurement. Conclusion. Time to procurement of CPAP was significantly shorter in those with Medicaid/Medicare insurance compared to the uninsured.

  1. An adaptive large neighborhood search procedure applied to the dynamic patient admission scheduling problem.

    PubMed

    Lusby, Richard Martin; Schwierz, Martin; Range, Troels Martin; Larsen, Jesper

    2016-11-01

    The aim of this paper is to provide an improved method for solving the so-called dynamic patient admission scheduling (DPAS) problem. This is a complex scheduling problem that involves assigning a set of patients to hospital beds over a given time horizon in such a way that several quality measures reflecting patient comfort and treatment efficiency are maximized. Consideration must be given to uncertainty in the length of stays of patients as well as the possibility of emergency patients. We develop an adaptive large neighborhood search (ALNS) procedure to solve the problem. This procedure utilizes a Simulated Annealing framework. We thoroughly test the performance of the proposed ALNS approach on a set of 450 publicly available problem instances. A comparison with the current state-of-the-art indicates that the proposed methodology provides solutions that are of comparable quality for small and medium sized instances (up to 1000 patients); the two approaches provide solutions that differ in quality by approximately 1% on average. The ALNS procedure does, however, provide solutions in a much shorter time frame. On larger instances (between 1000-4000 patients) the improvement in solution quality by the ALNS procedure is substantial, approximately 3-14% on average, and as much as 22% on a single instance. The time taken to find such results is, however, in the worst case, a factor 12 longer on average than the time limit which is granted to the current state-of-the-art. The proposed ALNS procedure is an efficient and flexible method for solving the DPAS problem. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Advances in Volcanic Ash Cloud Photogrammetry from Space

    NASA Astrophysics Data System (ADS)

    Zaksek, K.; von der Lieth, J.; Merucci, L.; Hort, M. K.; Gerst, A.; Carboni, E.; Corradini, S.

    2015-12-01

    The quality of ash dispersion prediction is limited by the lack of high quality information on eruption source parameters. One of the most important one is the ash cloud top height (ACTH). Because of well-known uncertainties of currently operational methods, photogrammetric methods can be used to improve height estimates. Some satellites have on board multiangular instruments that can be used for photogrammetrical observations. Volcanic ash clouds, however, can move with velocities over several m/s making these instruments inappropriate for accurate ACTH estimation. Thus we propose here two novel methods tested on different case studies (Etna 2013/11/23, Zhupanovsky 2014/09/10). The first method is based on NASA program Crew Earth observations from International Space Station (ISS). ISS has a lower orbit than most operational satellites, resulting in a shorter minimal time between two images required to produce a suitable parallax. In addition, images made by the ISS crew are taken by a full frame sensor and not a line scanner that most operational satellites use. Such data make possible to observe also short time evolution of clouds. The second method is based on the parallax between data retrieved from two geostationary instruments. We implemented a combination of MSG SEVIRI (HRV band; 1000 m nadir spatial resolution, 5 min temporal resolution) and METEOSAT7 MVIRI (VIS band, 2500 m nadir spatial resolution, 30 min temporal resolution). The procedure works well if the data from both satellites are retrieved nearly simultaneously. However, MVIRI does not retrieve the data at exactly the same time as SEVIRI. To compensate for advection in the atmosphere we use two sequential SEVIRI images (one before and one after the MVIRI retrieval) and interpolate the cloud position from SEVIRI data to the time of MVIRI retrieval.

  3. Simulating Mass Removal of Groundwater Contaminant Plumes with Complex and Simple Models

    NASA Astrophysics Data System (ADS)

    Lopez, J.; Guo, Z.; Fogg, G. E.

    2016-12-01

    Chlorinated solvents used in industrial, commercial, and other applications continue to pose significant threats to human health through contamination of groundwater resources. A recent National Research Council report concludes that it is unlikely that remediation of these complex sites will be achieved in a time frame of 50-100 years under current methods and standards (NRC, 2013). Pump and treat has been a common strategy at many sites to contain and treat groundwater contamination. In these sites, extensive retention of contaminant mass in low-permeability materials (tailing) has been observed after years or decades of pumping. Although transport models can be built that contain enough of the complex, 3D heterogeneity to simulate the tailing and long cleanup times, this is seldom done because of the large data and computational burdens. Hence, useful, reliable models to simulate various cleanup strategies are rare. The purpose of this study is to explore other potential ways to simulate the mass-removal processes with shorter time and less cost but still produce robust results by capturing effects of the heterogeneity and long-term retention of mass. A site containing a trichloroethylene groundwater plume was selected as the study area. The plume is located within alluvial sediments in the Tucson Basin. A fully heterogeneous domain is generated first and MODFLOW is used to simulate the flow field. Contaminant transport is simulated using both MT3D and RWHet for the fully heterogeneous model. Other approaches, including dual-domain mass transfer and heterogeneous chemical reactions, are manipulated to simulate the mass removal in a less heterogeneous, or homogeneous, domain and results are compared to the results obtained from complex models. The capability of these simpler models to simulate remediation processes, especially capture the late-time tailing, are examined.

  4. Smartphone application for mechanical quality assurance of medical linear accelerators

    NASA Astrophysics Data System (ADS)

    Kim, Hwiyoung; Lee, Hyunseok; In Park, Jong; Choi, Chang Heon; Park, So-Yeon; Kim, Hee Jung; Kim, Young Suk; Ye, Sung-Joon

    2017-06-01

    Mechanical quality assurance (QA) of medical linear accelerators consists of time-consuming and human-error-prone procedures. We developed a smartphone application system for mechanical QA. The system consists of two smartphones: one attached to a gantry for obtaining real-time information on the mechanical parameters of the medical linear accelerator, and another displaying real-time information via a Bluetooth connection with the former. Motion sensors embedded in the smartphone were used to measure gantry and collimator rotations. Images taken by the smartphone’s high-resolution camera were processed to evaluate accuracies of jaw-positioning, crosshair centering and source-to-surface distance (SSD). The application was developed using Android software development kit and OpenCV library. The accuracy and precision of the system was validated against an optical rotation stage and digital calipers, prior to routine QA measurements of five medical linear accelerators. The system accuracy and precision in measuring angles and lengths were determined to be 0.05  ±  0.05° and 0.25  ±  0.14 mm, respectively. The mean absolute errors (MAEs) in QA measurements of gantry and collimator rotation were 0.05  ±  0.04° and 0.05  ±  0.04°, respectively. The MAE in QA measurements of light field was 0.39  ±  0.36 mm. The MAEs in QA measurements of crosshair centering and SSD were 0.40  ±  0.35 mm and 0.41  ±  0.32 mm, respectively. In conclusion, most routine mechanical QA procedures could be performed using the smartphone application system with improved precision and within a shorter time-frame, while eliminating potential human errors.

  5. Smartphone application for mechanical quality assurance of medical linear accelerators.

    PubMed

    Kim, Hwiyoung; Lee, Hyunseok; Park, Jong In; Choi, Chang Heon; Park, So-Yeon; Kim, Hee Jung; Kim, Young Suk; Ye, Sung-Joon

    2017-06-07

    Mechanical quality assurance (QA) of medical linear accelerators consists of time-consuming and human-error-prone procedures. We developed a smartphone application system for mechanical QA. The system consists of two smartphones: one attached to a gantry for obtaining real-time information on the mechanical parameters of the medical linear accelerator, and another displaying real-time information via a Bluetooth connection with the former. Motion sensors embedded in the smartphone were used to measure gantry and collimator rotations. Images taken by the smartphone's high-resolution camera were processed to evaluate accuracies of jaw-positioning, crosshair centering and source-to-surface distance (SSD). The application was developed using Android software development kit and OpenCV library. The accuracy and precision of the system was validated against an optical rotation stage and digital calipers, prior to routine QA measurements of five medical linear accelerators. The system accuracy and precision in measuring angles and lengths were determined to be 0.05  ±  0.05° and 0.25  ±  0.14 mm, respectively. The mean absolute errors (MAEs) in QA measurements of gantry and collimator rotation were 0.05  ±  0.04° and 0.05  ±  0.04°, respectively. The MAE in QA measurements of light field was 0.39  ±  0.36 mm. The MAEs in QA measurements of crosshair centering and SSD were 0.40  ±  0.35 mm and 0.41  ±  0.32 mm, respectively. In conclusion, most routine mechanical QA procedures could be performed using the smartphone application system with improved precision and within a shorter time-frame, while eliminating potential human errors.

  6. Space Shuttle Main Engine Propellant Path Leak Detection Using Sequential Image Processing

    NASA Technical Reports Server (NTRS)

    Smith, L. Montgomery; Malone, Jo Anne; Crawford, Roger A.

    1995-01-01

    Initial research in this study using theoretical radiation transport models established that the occurrence of a leak is accompanies by a sudden but sustained change in intensity in a given region of an image. In this phase, temporal processing of video images on a frame-by-frame basis was used to detect leaks within a given field of view. The leak detection algorithm developed in this study consists of a digital highpass filter cascaded with a moving average filter. The absolute value of the resulting discrete sequence is then taken and compared to a threshold value to produce the binary leak/no leak decision at each point in the image. Alternatively, averaging over the full frame of the output image produces a single time-varying mean value estimate that is indicative of the intensity and extent of a leak. Laboratory experiments were conducted in which artificially created leaks on a simulated SSME background were produced and recorded from a visible wavelength video camera. This data was processed frame-by-frame over the time interval of interest using an image processor implementation of the leak detection algorithm. In addition, a 20 second video sequence of an actual SSME failure was analyzed using this technique. The resulting output image sequences and plots of the full frame mean value versus time verify the effectiveness of the system.

  7. Optical Diagnostic System For Observation Of Laser-Produced Shock Waves

    NASA Astrophysics Data System (ADS)

    Wilke, Mark D.; Stone, Sidney N.

    1980-11-01

    Several standard plasma and gas dynamic diagnostic techniques have been integrated into a system for observing the formation and propagation of high-power Nd:glass-laser generated one- and two-dimensional shockwaves in air from 0.1 torr to atmospheric pres-sures. Diagnostics include either single-frame, two-wavelength holographic ruby-laser interferometry or single-frame, single-wavelength interferometry with ten frames of shadow-graphy. Streaks or ten frames of the early luminous shocked region also are taken on all shots, as well as time-resolved luminosity measurements using high-speed biplanar vacuum photodiodes with various wavelength interference filters. Shadowgraphy frames are 200-ns long at 1-μs intervals, while emission frames are variable with a maximum 10-ns exposure and 50-ns interval. Both the streak mode and emission measurements with the vacuum diode allow subnanosecond time resolution. The interferometry provides 20-ns exposures from 500 ns to late times. Methods for reducing and interpreting the data have been, or are currently being, developed. Interactive computer programs for digitizing the fringe patterns provide fringe-shift profiles for Abel inversion. This has provided neutral gas and electron density information in the spherical, one-dimensional cases. Diagrams and photographs of the experiment will be shown as well as examples of the data that have been taken. Methods for data reduction will be outlined and some of the results shown.

  8. 31 CFR Appendix A to Part 5 - Treasury Directive 34-01-Waiving Claims Against Treasury Employees for Erroneous Payments

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the time of the determination, to deduct up to 15%, or a greater amount if agreed to by the employee... procedures; (3) Establish time frames for employees to request a waiver in writing and for the bureau to review the waiver request. These time frames must take into consideration the responsibilities of the...

  9. Time and flow-direction responses of shear-styress-sensitive liquid crystal coatings

    NASA Technical Reports Server (NTRS)

    Reda, Daniel C.; Muraqtore, J. J.; Heinick, James T.

    1994-01-01

    Time and flow-direction responses of shear-stress liquid crystal coatings were exploresd experimentally. For the time-response experiments, coatings were exposed to transient, compressible flows created during the startup and off-design operation of an injector-driven supersonic wind tunnel. Flow transients were visualized with a focusing schlieren system and recorded with a 100 frame/s color video camera.

  10. Real-time look-up table-based color correction for still image stabilization of digital cameras without using frame memory

    NASA Astrophysics Data System (ADS)

    Luo, Lin-Bo; An, Sang-Woo; Wang, Chang-Shuai; Li, Ying-Chun; Chong, Jong-Wha

    2012-09-01

    Digital cameras usually decrease exposure time to capture motion-blur-free images. However, this operation will generate an under-exposed image with a low-budget complementary metal-oxide semiconductor image sensor (CIS). Conventional color correction algorithms can efficiently correct under-exposed images; however, they are generally not performed in real time and need at least one frame memory if they are implemented by hardware. The authors propose a real-time look-up table-based color correction method that corrects under-exposed images with hardware without using frame memory. The method utilizes histogram matching of two preview images, which are exposed for a long and short time, respectively, to construct an improved look-up table (ILUT) and then corrects the captured under-exposed image in real time. Because the ILUT is calculated in real time before processing the captured image, this method does not require frame memory to buffer image data, and therefore can greatly save the cost of CIS. This method not only supports single image capture, but also bracketing to capture three images at a time. The proposed method was implemented by hardware description language and verified by a field-programmable gate array with a 5 M CIS. Simulations show that the system can perform in real time with a low cost and can correct the color of under-exposed images well.

  11. Effects of context on risk taking and decision times in obsessive-compulsive disorder.

    PubMed

    Sip, Kamila E; Muratore, Alexandra F; Stern, Emily R

    2016-04-01

    Despite the fact that OCD patients show altered decision making in everyday life, few studies have investigated how patients make risky decisions and what contextual factors impact choices. We investigated cognitive context with the use of the "framing effect" task, which investigates decision making based on whether monetarily equivalent choice options are framed in terms of a potential to either lose (lose $20 out of $50) or gain (gain $30 out of $50) money. In addition, we manipulated social context by providing positive or neutral feedback on subjects' choices. Overall, participants were risk taking for options framed in terms of potential loss and risk averse for options framed in terms of potential gain (the classic framing effect). Although OCD patients were generally more risk averse, the effect of the frame on choices did not differ significantly from healthy participants and choices were not impacted by social context. Within OCD patients, greater self-reported indecisiveness was associated with a larger effect of the frame on choices. OCD patients were also significantly slower to make choices in the loss compared to gain frame, an effect that was not observed among healthy participants. Overall, our results suggest that the framing of choice options has a differential effect on decision times but not the actual choices made by OCD patients, and that patients are not sensitive to social feedback when making choices. The correlation between indecisiveness and the framing effect in OCD suggests that further work interrogating the relationship between specific symptoms and decision making among patients may yield new insights into the disorder. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Anesthetic efficacy of ketamine–diazepam, ketamine–xylazine, and ketamine–acepromazine in Caspian Pond turtles (Mauremys caspica)

    PubMed Central

    Adel, Milad; Sadegh, Amin Bigham; Arizza, Vincenzo; Abbasi, Hossein; Inguglia, Luigi; Saravi, Hasan Nasrollahzadeh

    2017-01-01

    Objectives: The objective of this study was to assess the efficacy of different anesthetic drug combinations on the Caspian Pond turtles (Mauremys caspica). Subjects and Methods: Three groups of the Caspian Pond turtles (n = 6) were anesthetized with three different drug combinations. Initially, a pilot study was conducted to determine the best drug doses for the anesthetization of the turtles, and according to these results, ketamine–diazepam (120 mg/kg ketamine hydrochloride [5%] and 2 mg/kg diazepam [5%]), ketamine–acepromazine (120 mg/kg ketamine hydrochloride [5%] and 1 mg/kg acepromazine [1%]), and ketamine–xylazine (120 mg/kg ketamine hydrochloride [5%] and 1 mg/kg xylazine [2%]) were injected intramuscularly. The onset times of anesthetization and the recovery time were measured. Statistical analysis of the data was performed using one-way analysis of variance followed by t-tests, and P < 0.05 was considered statistically significant. Results: There were statistically significant differences in the mean of the onset times of anesthesia and recovery time among the three drug combinations depending on the treatment used. The onset of anesthesia of the animals treated with the ketamine–diazepam combination was 60% and 42% shorter, for male and female turtles, respectively, compared to that obtained with the ketamine–acepromazine combination and 64% (male turtles) and 50% (female turtles) shorter than that obtained with the ketamine–xylazine combination. Further, the recovery time, in male turtles, was 17% shorter in animals treated with the first drug combination than those treated with the ketamine–acepromazine combination and 37% shorter than those treated with the ketamine–xylazine combination. The recovery time, in female turtles, did not seem to be significantly different among treatments. Conclusions: The study showed that the ketamine–diazepam drug combination is the anesthetic combination with the fastest onset time and shortest recovery time. PMID:28458430

  13. 77 FR 62191 - Approval and Promulgation of Air Quality Implementation Plans; New Mexico; Infrastructure and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-12

    ... such shorter period as EPA may prescribe. Section 110(a)(2) lists the specific infrastructure elements... Act (Act) requires that each state adopt and submit to EPA, within 3 years (or such shorter time... Tailoring Rule because the State does not have the authority to apply the meaning of the term ``subject to...

  14. Reactive nanolaminate pulsed-laser ignition mechanism: Modeling and experimental evidence of diffusion limited reactions

    DOE PAGES

    Yarrington, C. D.; Abere, M. J.; Adams, D. P.; ...

    2017-04-03

    We irradiated Al/Pt nanolaminates with a bilayer thickness (tb, width of an Al/Pt pair-layer) of 164 nm with single laser pulses with durations of 10 ms and 0.5 ms at 189 W/cm 2 and 1189 W/cm 2, respectively. The time to ignition was measured for each pulse, and shorter ignition times were observed for the higher power/shorter pulse width. While the shorter pulse shows uniform brightness, videographic images of the irradiated area shortly after ignition show a non-uniform radial brightness for the longer pulse. A diffusion-limited single step reaction mechanism was implemented in a finite element package to model themore » progress from reactants to products at both pulse widths. Finally, the model captures well both the observed ignition delay and qualitative observations regarding the non-uniform radial temperature.« less

  15. The Effect of Hyperbaric Oxygen on the Growth of Mucor sp. Aspergillus fumigatus.

    DTIC Science & Technology

    1980-02-01

    designations are for controls. 12 mamo 7<)U 4/ Figure 2. Aspergillus fumigatus Top Frame - Hyphae at day 2. Middle Frame - Plyphae with developing...conidiaphores, day 3. L~ower Frame - Hyphae with conidiophores and conidia, day 4. Time~ designations are for co~ntrols. 14 0 lOum Figure 3. Grouth curves

  16. How Does Expansive Framing Promote Transfer? Several Proposed Explanations and a Research Agenda for Investigating Them

    ERIC Educational Resources Information Center

    Engle, Randi A.; Lam, Diane P.; Meyer, Xenia S.; Nix, Sarah E.

    2012-01-01

    When contexts are framed expansively, students are positioned as actively contributing to larger conversations that extend across time, places, and people. A set of recent studies provides empirical evidence that the expansive framing of contexts can foster transfer. In this article, we present five potentially complementary explanations for how…

  17. Spot-Welding Gun Is Easy To Use

    NASA Technical Reports Server (NTRS)

    Morgan, Gene E.; Nguyen, Francis H.

    1991-01-01

    Electrical-resistance spot-welding gun designed to produce more welds per unit time by decreasing technician's effort and fatigue. Vacuum cups on frame secure welding gun to workpiece while compressed air drives welding tip against workpiece to make spot resistance weld. When weld completed, vacuum in frame cups released so frame and gun moved to position of next spot weld.

  18. High-Speed Large-Alphabet Quantum Key Distribution Using Photonic Integrated Circuits

    DTIC Science & Technology

    2014-01-28

    polarizing beam splitter, TDC: time-to-digital converter. Extra&loss& photon/bin frame size QSER secure bpp ECC secure&key&rate& none& 0.0031 64 14...to-digital converter. photon/frame frame size QSER secure bpp ECC secure&key& rate& 1.3 16 9.5 % 2.9 layered LDPC 7.3&Mbps& Figure 24: Operating

  19. Optimization of a shorter variable-acquisition time for legs to achieve true whole-body PET/CT images.

    PubMed

    Umeda, Takuro; Miwa, Kenta; Murata, Taisuke; Miyaji, Noriaki; Wagatsuma, Kei; Motegi, Kazuki; Terauchi, Takashi; Koizumi, Mitsuru

    2017-12-01

    The present study aimed to qualitatively and quantitatively evaluate PET images as a function of acquisition time for various leg sizes, and to optimize a shorter variable-acquisition time protocol for legs to achieve better qualitative and quantitative accuracy of true whole-body PET/CT images. The diameters of legs to be modeled as phantoms were defined based on data derived from 53 patients. This study analyzed PET images of a NEMA phantom and three plastic bottle phantoms (diameter, 5.68, 8.54 and 10.7 cm) that simulated the human body and legs, respectively. The phantoms comprised two spheres (diameters, 10 and 17 mm) containing fluorine-18 fluorodeoxyglucose solution with sphere-to-background ratios of 4 at a background radioactivity level of 2.65 kBq/mL. All PET data were reconstructed with acquisition times ranging from 10 to 180, and 1200 s. We visually evaluated image quality and determined the coefficient of variance (CV) of the background, contrast and the quantitative %error of the hot spheres, and then determined two shorter variable-acquisition protocols for legs. Lesion detectability and quantitative accuracy determined based on maximum standardized uptake values (SUV max ) in PET images of a patient using the proposed protocols were also evaluated. A larger phantom and a shorter acquisition time resulted in increased background noise on images and decreased the contrast in hot spheres. A visual score of ≥ 1.5 was obtained when the acquisition time was ≥ 30 s for three leg phantoms, and ≥ 120 s for the NEMA phantom. The quantitative %errors of the 10- and 17-mm spheres in the leg phantoms were ± 15 and ± 10%, respectively, in PET images with a high CV (scan < 30 s). The mean SUV max of three lesions using the current fixed-acquisition and two proposed variable-acquisition time protocols in the clinical study were 3.1, 3.1 and 3.2, respectively, which did not significantly differ. Leg acquisition time per bed position of even 30-90 s allows axial equalization, uniform image noise and a maximum ± 15% quantitative accuracy for the smallest lesion. The overall acquisition time was reduced by 23-42% using the proposed shorter variable than the current fixed-acquisition time for imaging legs, indicating that this is a useful and practical protocol for routine qualitative and quantitative PET/CT assessment in the clinical setting.

  20. Flight behaviour of honey bee (Apis mellifera) workers is altered by initial infections of the fungal parasite Nosema apis

    PubMed Central

    Dosselli, Ryan; Grassl, Julia; Carson, Andrew; Simmons, Leigh W.; Baer, Boris

    2016-01-01

    Honey bees (Apis mellifera) host a wide range of parasites, some being known contributors towards dramatic colony losses as reported over recent years. To counter parasitic threats, honey bees possess effective immune systems. Because immune responses are predicted to cause substantial physiological costs for infected individuals, they are expected to trade off with other life history traits that ultimately affect the performance and fitness of the entire colony. Here, we tested whether the initial onset of an infection negatively impacts the flight behaviour of honey bee workers, which is an energetically demanding behaviour and a key component of foraging activities. To do this, we infected workers with the widespread fungal pathogen Nosema apis, which is recognised and killed by the honey bee immune system. We compared their survival and flight behaviour with non-infected individuals from the same cohort and colony using radio frequency identification tags (RFID). We found that over a time frame of four days post infection, Nosema did not increase mortality but workers quickly altered their flight behaviour and performed more flights of shorter duration. We conclude that parasitic infections influence foraging activities, which could reduce foraging ranges of colonies and impact their ability to provide pollination services. PMID:27827404

  1. Short wavelength ion waves upstream of the earth's bow shock

    NASA Technical Reports Server (NTRS)

    Fuselier, S. A.; Gurnett, D. A.

    1984-01-01

    The identification and explanation of short wavelength antenna interference effects observed in spacecraft plasma wave data have provided an important new method of determining limits on the wavelength, direction of propagation, and Doppler shift of short wavelength electrostatic waves. Using the ISEE-1 wideband electric field data, antenna interference effects have been identified in the ion waves upstream of the earth's bow shock. This identification implies that wavelengths of the upstream ion waves are shorter than the antenna length. The interference effects also provide new measurements of the direction of propagation of the ion waves. The new measurements show that the wave vectors of the ion waves are not parallel to the interplanetary magnetic field (IMF) as previously reported. The direction of propagation does not appear to be controlled by the IMF. In addition, analysis of the Doppler shift of the short wavelength ion waves has provided a measurement of the dispersion relation. The upper limit of the rest frame frequency was found to be on the order of the ion plasma frequency. At this frequency, the wavelength is on the order of a few times the Debye length. The results of this study now provide strong evidence that the ion waves in the upstream region are Doppler-shifted ion acoustic waves. Previously announced in STAR as N83-36328

  2. Optimal speckle noise reduction filter for range gated laser illuminated imaging

    NASA Astrophysics Data System (ADS)

    Dayton, David; Gonglewski, John; Lasche, James; Hassall, Arthur

    2016-09-01

    Laser illuminated imaging has a number of applications in the areas of night time air-to-ground target surveillance, ID, and pointing and tracking. Using a laser illuminator, the illumination intensity and thus the signal to noise ratio can be controlled. With the advent of high performance range gated cameras in the short-wave infra-red band, higher spatial resolution can be achieved over passive thermal night imaging cameras in the mid-wave infra-red due to the shorter wave-length. If a coherent illuminator is used the resulting imagery often suffers from speckle noise due to the scattering off of a rough target surface, which gives it a grainy "salt and pepper" appearance. The probability density function for the intensity of focal plane speckle is well understood to follow a negative exponential distribution. This can be exploited to develop a Bayesian speckle noise filter. The filter has the advantage over simple frame averaging approaches in that it preserves target features and motion while reducing speckle noise without smearing or blurring the images. The resulting filtered images have the appearance of passive imagery and so are more amenable to sensor fusion with simultaneous mid-wave infra-red thermal images for enhanced target ID. The noise filter improvement is demonstrated using examples from real world laser imaging tests on tactical targets.

  3. Flight behaviour of honey bee (Apis mellifera) workers is altered by initial infections of the fungal parasite Nosema apis.

    PubMed

    Dosselli, Ryan; Grassl, Julia; Carson, Andrew; Simmons, Leigh W; Baer, Boris

    2016-11-09

    Honey bees (Apis mellifera) host a wide range of parasites, some being known contributors towards dramatic colony losses as reported over recent years. To counter parasitic threats, honey bees possess effective immune systems. Because immune responses are predicted to cause substantial physiological costs for infected individuals, they are expected to trade off with other life history traits that ultimately affect the performance and fitness of the entire colony. Here, we tested whether the initial onset of an infection negatively impacts the flight behaviour of honey bee workers, which is an energetically demanding behaviour and a key component of foraging activities. To do this, we infected workers with the widespread fungal pathogen Nosema apis, which is recognised and killed by the honey bee immune system. We compared their survival and flight behaviour with non-infected individuals from the same cohort and colony using radio frequency identification tags (RFID). We found that over a time frame of four days post infection, Nosema did not increase mortality but workers quickly altered their flight behaviour and performed more flights of shorter duration. We conclude that parasitic infections influence foraging activities, which could reduce foraging ranges of colonies and impact their ability to provide pollination services.

  4. The Impact of Biosampling Procedures on Molecular Data Interpretation*

    PubMed Central

    Sköld, Karl; Alm, Henrik; Scholz, Birger

    2013-01-01

    The separation between biological and technical variation without extensive use of technical replicates is often challenging, particularly in the context of different forms of protein and peptide modifications. Biosampling procedures in the research laboratory are easier to conduct within a shorter time frame and under controlled conditions as compared with clinical sampling, with the latter often having issues of reproducibility. But is the research laboratory biosampling really less variable? Biosampling introduces within minutes rapid tissue-specific changes in the cellular microenvironment, thus inducing a range of different pathways associated with cell survival. Biosampling involves hypoxia and, depending on the circumstances, hypothermia, circumstances for which there are evolutionarily conserved defense strategies in the range of species and also are relevant for the range of biomedical conditions. It remains unclear to what extent such adaptive processes are reflected in different biosampling procedures or how important they are for the definition of sample quality. Lately, an increasing number of comparative studies on different biosampling approaches, post-mortem effects and pre-sampling biological state, have investigated such immediate early biosampling effects. Commonalities between biosampling effects and a range of ischemia/reperfusion- and hypometabolism/anoxia-associated biological phenomena indicate that even small variations in post-sampling time intervals are likely to introduce a set of nonrandom and tissue-specific effects of experimental importance (both in vivo and in vitro). This review integrates the information provided by these comparative studies and discusses how an adaptive biological perspective in biosampling procedures may be relevant for sample quality issues. PMID:23382104

  5. Active optics for next generation space telescopes

    NASA Astrophysics Data System (ADS)

    Costes, V.; Perret, L.; Laubier, D.; Delvit, J. M.; Imbert, C.; Cadiergues, L.; Faure, C.

    2017-09-01

    High resolution observation systems need bigger and bigger telescopes. The design of such telescopes is a key issue for the whole satellite. In order to improve the imaging resolution with minimum impact on the satellite, a big effort must be made to improve the telescope compactness. Compactness is also important for the agility of the satellite and for the size and cost of the launcher. This paper shows how compact a high resolution telescope can be. A diffraction limited telescope can be less than ten times shorter than its focal length. But the compactness impacts drastically the opto-mechanical sensitivity and the optical performances. Typically, a gain of a factor of 2 leads to a mechanical tolerance budget 6 times more difficult. The need to implement active optics for positioning requirements raises very quickly. Moreover, the capability to compensate shape defaults of the primary mirror is the way to simplify the mirror manufacture, to mitigate the development risks and to minimize the cost. The larger the primary mirror is, the more interesting it is to implement active optics for shape compensations. CNES is preparing next generation of earth observation satellite in the frame of OTOS (Observation de la Terre Optique Super-Résolue; High resolution earth observing optical system). OTOS is a technology program. In particular, optical technological developments and breadboards dedicated to active optics are on-going. The aim is to achieve TRL 5 to TRL6 for these new technologies and to validate the global performances of such an active telescope.

  6. Voltage-based device tracking in a 1.5 Tesla MRI during imaging: initial validation in swine models.

    PubMed

    Schmidt, Ehud J; Tse, Zion T H; Reichlin, Tobias R; Michaud, Gregory F; Watkins, Ronald D; Butts-Pauly, Kim; Kwong, Raymond Y; Stevenson, William; Schweitzer, Jeffrey; Byrd, Israel; Dumoulin, Charles L

    2014-03-01

    Voltage-based device-tracking (VDT) systems are commonly used for tracking invasive devices in electrophysiological cardiac-arrhythmia therapy. During electrophysiological procedures, electro-anatomic mapping workstations provide guidance by integrating VDT location and intracardiac electrocardiogram information with X-ray, computerized tomography, ultrasound, and MR images. MR assists navigation, mapping, and radiofrequency ablation. Multimodality interventions require multiple patient transfers between an MRI and the X-ray/ultrasound electrophysiological suite, increasing the likelihood of patient-motion and image misregistration. An MRI-compatible VDT system may increase efficiency, as there is currently no single method to track devices both inside and outside the MRI scanner. An MRI-compatible VDT system was constructed by modifying a commercial system. Hardware was added to reduce MRI gradient-ramp and radiofrequency unblanking pulse interference. VDT patches and cables were modified to reduce heating. Five swine cardiac VDT electro-anatomic mapping interventions were performed, navigating inside and thereafter outside the MRI. Three-catheter VDT interventions were performed at >12 frames per second both inside and outside the MRI scanner with <3 mm error. Catheters were followed on VDT- and MRI-derived maps. Simultaneous VDT and imaging was possible in repetition time >32 ms sequences with <0.5 mm errors, and <5% MRI signal-to-noise ratio (SNR) loss. At shorter repetition times, only intracardiac electrocardiogram was reliable. Radiofrequency heating was <1.5°C. An MRI-compatible VDT system is feasible. Copyright © 2013 Wiley Periodicals, Inc.

  7. Health insurance instability among older immigrants: region of origin disparities in coverage.

    PubMed

    Reyes, Adriana M; Hardy, Melissa

    2015-03-01

    We provide a detailed analysis of how the dynamics of health insurance coverage (HIC) at older ages differs among Latino, Asian, and European immigrants in the United States. Using Survey of Income and Program Participation data from the 2004 and 2008 panels, we estimate discrete-time event history models to examine first and second transitions into and out of HIC, highlighting substantial differences in hazard rates among immigrants aged 50-64 from Asia, Latin America, and Europe. We find that the likelihood of having HIC at first observation and the rates of gaining and losing coverage within a relatively short time frame are least favorable for older Latino immigrants, although immigrants from all three regions are at a disadvantage relative to native-born non-Hispanic Whites. This disparity among immigrant groups persists even when lower rates of citizenship, greater difficulty with English, and low-skill job placements are taken into account. Factors that have contributed to the lower rates and shorter durations of HIC among older immigrants, particularly those from Latin America, may not be easily resolved by the Affordable Care Act. The importance of region of origin and assimilation characteristics for the risk of being uninsured in later life argues that immigration and health care policy should be jointly addressed. © The Author 2015. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Enhanced Early View of Ceres from Dawn

    NASA Image and Video Library

    2014-12-05

    As the Dawn spacecraft flies through space toward the dwarf planet Ceres, the unexplored world appears to its camera as a bright light in the distance, full of possibility for scientific discovery. This view was acquired as part of a final calibration of the science camera before Dawn's arrival at Ceres. To accomplish this, the camera needed to take pictures of a target that appears just a few pixels across. On Dec. 1, 2014, Ceres was about nine pixels in diameter, nearly perfect for this calibration. The images provide data on very subtle optical properties of the camera that scientists will use when they analyze and interpret the details of some of the pictures returned from orbit. Ceres is the bright spot in the center of the image. Because the dwarf planet is much brighter than the stars in the background, the camera team selected a long exposure time to make the stars visible. The long exposure made Ceres appear overexposed, and exaggerated its size; this was corrected by superimposing a shorter exposure of the dwarf planet in the center of the image. A cropped, magnified view of Ceres appears in the inset image at lower left. The image was taken on Dec. 1, 2014 with the Dawn spacecraft's framing camera, using a clear spectral filter. Dawn was about 740,000 miles (1.2 million kilometers) from Ceres at the time. Ceres is 590 miles (950 kilometers) across and was discovered in 1801. http://photojournal.jpl.nasa.gov/catalog/PIA19050

  9. [Systemic coronary surgery in the beating heart. Experience in 250 cases].

    PubMed

    Cartier, R; Bouchard, D; Martineau, R; Couturier, A

    1999-01-01

    To report our recent experience with off-pump coronary artery revascularization in multi-vessel disease. Between October 1996 and August 1998, 250 off-pump (OP) procedures were completed at the Montreal Heart Institute, representing more than 90% of all procedures done during the same time frame (97% for 1998). These patients have been compared to 1870 patients operated upon under cardiopulmonary bypass during the years 1995-1996 (CPB). Mean age, sexe distribution, and preoperative risk factors were comparable for both groups. On average 2.89 +/- 0.8 and 2.84 +/- 0.6 grafts/patient were completed in OP and CPB groups respectively. A majority (70%) of patients had either a triple or quadruple bypass. Coronary anastomoses were achieved with myocardial mechanical stabilization and heart "verticalization". Ischemic time was shorter in the OP group (29.8 +/- 0.9 vs 45 +/- 0.4 min, p < 0.05). Similarly, need for transfusion was significantly less (OP: 34 vs CPB: 66%, p < 0.005). Use of postoperative intra-aortic counterpulsation as well as the raise of CK-MB were lesser in the OP group. Operative mortality (OP: 1.6%, vs CPB: 2%, p = ns) and perioperative myocardial infarction rate (OP: 3.6% vs CPB: 4.2) were comparable for both groups. Off-pump complete coronary artery revascularization is an acceptable alternative to conventional surgery in a majority of patients with good results given progressive experience, rigorous technique, and adequate coronary artery stabilization.

  10. Imaging the Frame: Media Representations of Teachers, Their Unions, NCLB, and Education Reform

    ERIC Educational Resources Information Center

    Goldstein, Rebecca A.

    2011-01-01

    This article examines the political discourse surrounding NCLB, educational reform, and how that discourse shaped perceptions of public education during the Bush Administration. Examining mass media campaigns in the New York Times and Time Magazine, the article demonstrates how the media has visually and textually framed and reinforced NCLB and…

  11. High Resolution Anatomic and Elastographic Transrectal Ultrasound for Improved Diagnosis of Prostate Cancer

    DTIC Science & Technology

    2005-02-01

    2004. 3. Pesavento , A. and A. Lorenz. Real time stain imaging and in vivo applications in prostate cancer, in IEEE Ultrasonics Symposium. 2001. 4...Symposium. 2000. 6. Pesavento A, L.A., Ermert H, Sommerfeld H, Garcia-Schurmann M, Senge Th, Philippou S. Frame-to-frame statistics of real-time strain

  12. 21 CFR 814.40 - Time frames for reviewing a PMA.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES PREMARKET APPROVAL OF MEDICAL DEVICES FDA Action on a PMA § 814.40 Time frames for... the applicant does not submit a major amendment, FDA will review the PMA and, after receiving the report and recommendation of the appropriate FDA advisory committee, send the applicant an approval order...

  13. 21 CFR 814.40 - Time frames for reviewing a PMA.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES PREMARKET APPROVAL OF MEDICAL DEVICES FDA Action on a PMA § 814.40 Time frames for... the applicant does not submit a major amendment, FDA will review the PMA and, after receiving the report and recommendation of the appropriate FDA advisory committee, send the applicant an approval order...

  14. 21 CFR 814.40 - Time frames for reviewing a PMA.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES PREMARKET APPROVAL OF MEDICAL DEVICES FDA Action on a PMA § 814.40 Time frames for... the applicant does not submit a major amendment, FDA will review the PMA and, after receiving the report and recommendation of the appropriate FDA advisory committee, send the applicant an approval order...

  15. Suitability of the echo-time-shift method as laboratory standard for thermal ultrasound dosimetry

    NASA Astrophysics Data System (ADS)

    Fuhrmann, Tina; Georg, Olga; Haller, Julian; Jenderka, Klaus-Vitold

    2017-03-01

    Ultrasound therapy is a promising, non-invasive application with potential to significantly improve cancer therapies like surgery, viro- or immunotherapy. This therapy needs faster, cheaper and more easy-to-handle quality assurance tools for therapy devices as well as possibilities to verify treatment plans and for dosimetry. This limits comparability and safety of treatments. Accurate spatial and temporal temperature maps could be used to overcome these shortcomings. In this contribution first results of suitability and accuracy investigations of the echo-time-shift method for two-dimensional temperature mapping during and after sonication are presented. The analysis methods used to calculate time-shifts were a discrete frame-to-frame and a discrete frame-to-base-frame algorithm as well as a sigmoid fit for temperature calculation. In the future accuracy could be significantly enhanced by using continuous methods for time-shift calculation. Further improvements can be achieved by improving filtering algorithms and interpolation of sampled diagnostic ultrasound data. It might be a comparatively accurate, fast and affordable method for laboratory and clinical quality control.

  16. Controlling Surface Plasmons Through Covariant Transformation of the Spin-Dependent Geometric Phase Between Curved Metamaterials

    NASA Astrophysics Data System (ADS)

    Zhong, Fan; Li, Jensen; Liu, Hui; Zhu, Shining

    2018-06-01

    General relativity uses curved space-time to describe accelerating frames. The movement of particles in different curved space-times can be regarded as equivalent physical processes based on the covariant transformation between different frames. In this Letter, we use one-dimensional curved metamaterials to mimic accelerating particles in curved space-times. The different curved shapes of structures are used to mimic different accelerating frames. The different geometric phases along the structure are used to mimic different movements in the frame. Using the covariant principle of general relativity, we can obtain equivalent nanostructures based on space-time transformations, such as the Lorentz transformation and conformal transformation. In this way, many covariant structures can be found that produce the same surface plasmon fields when excited by spin photons. A new kind of accelerating beam, the Rindler beam, is obtained based on the Rindler metric in gravity. Very large effective indices can be obtained in such systems based on geometric-phase gradient. This general covariant design method can be extended to many other optical media.

  17. Framing the ecosystem concept through a longitudinal study of developments in science and policy.

    PubMed

    Aggestam, Filip

    2015-08-01

    This paper examines how scientific literature and policy documents frame the ecosystem concept and how these frames have shaped scientific dialogue and policy making over time. This was achieved by developing a frame typology, as a basis for organizing relevant value expressions, to assess how different frames have altered perspectives of the ecosystem concept. The frame typology and analysis is based on a semi-grounded and longitudinal document analysis of scientific literature and policy documents using the ecosystem concept. Despite changing discourses and public priorities (e.g., cultural constructs of biodiversity) both science and policy documents are characterized by stable value systems that have not changed substantially since the 1930s. These value systems were defined based on ethical principles that delineate 6 core frames: humans first, dual systems, eco-science, eco-holism, animals first, and multicentrism. Specific crises (e.g., climate change) and cross-disciplinary uptake and re-uptake of, for example, the ecosystem services concept, have brought new perspectives to the forefront of public discourse. These developments triggered changes in the core frames that, rather than being value based, are based on how the ecosystem is conceptualized under fixed value systems and over time. Fourteen subframes were developed to reflect these longitudinal changes. There are as such clear framing effects in both scientific literature and in policy. Ecosystem research is for instance often characterized by unstated value judgments even though the scientific community does not make these explicit. In contrast, policy documents are characterized by clear value expressions but are principally management driven and human centered. © 2015 Society for Conservation Biology.

  18. Hardware accelerator design for change detection in smart camera

    NASA Astrophysics Data System (ADS)

    Singh, Sanjay; Dunga, Srinivasa Murali; Saini, Ravi; Mandal, A. S.; Shekhar, Chandra; Chaudhury, Santanu; Vohra, Anil

    2011-10-01

    Smart Cameras are important components in Human Computer Interaction. In any remote surveillance scenario, smart cameras have to take intelligent decisions to select frames of significant changes to minimize communication and processing overhead. Among many of the algorithms for change detection, one based on clustering based scheme was proposed for smart camera systems. However, such an algorithm could achieve low frame rate far from real-time requirements on a general purpose processors (like PowerPC) available on FPGAs. This paper proposes the hardware accelerator capable of detecting real time changes in a scene, which uses clustering based change detection scheme. The system is designed and simulated using VHDL and implemented on Xilinx XUP Virtex-IIPro FPGA board. Resulted frame rate is 30 frames per second for QVGA resolution in gray scale.

  19. Life history traits in selfing versus outcrossing annuals: exploring the 'time-limitation' hypothesis for the fitness benefit of self-pollination

    PubMed Central

    Snell, Rebecca; Aarssen, Lonnie W

    2005-01-01

    Background Most self-pollinating plants are annuals. According to the 'time-limitation' hypothesis, this association between selfing and the annual life cycle has evolved as a consequence of strong r-selection, involving severe time-limitation for completing the life cycle. Under this model, selection from frequent density-independent mortality in ephemeral habitats minimizes time to flower maturation, with selfing as a trade-off, and / or selection minimizes the time between flower maturation and ovule fertilization, in which case selfing has a direct fitness benefit. Predictions arising from this hypothesis were evaluated using phylogenetically-independent contrasts of several life history traits in predominantly selfing versus outcrossing annuals from a data base of 118 species distributed across 14 families. Data for life history traits specifically related to maturation and pollination times were obtained by monitoring the start and completion of different stages of reproductive development in a greenhouse study of selfing and outcrossing annuals from an unbiased sample of 25 species involving five pair-wise family comparisons and four pair-wise genus comparisons. Results Selfing annuals in general had significantly shorter plant heights, smaller flowers, shorter bud development times, shorter flower longevity and smaller seed sizes compared with their outcrossing annual relatives. Age at first flower did not differ significantly between selfing and outcrossing annuals. Conclusions This is the first multi-species study to report these general life-history differences between selfers and outcrossers among annuals exclusively. The results are all explained more parsimoniously by selection associated with time-limitation than by selection associated with pollinator/mate limitation. The shorter bud development time reported here for selfing annuals is predicted explicitly by the time-limitation hypothesis for the fitness benefit of selfing (and not by the alternative 'reproductive assurance' hypothesis associated with pollinator/mate limitation). Support for the time-limitation hypothesis is also evident from published surveys: whereas selfers and outcrossers are about equally represented among annual species as a whole, selfers occur in much higher frequencies among the annual species found in two of the most severely time-limited habitats where flowering plants grow – deserts and cultivated habitats. PMID:15707481

  20. Individual differences in drivers' cognitive processing of road safety messages.

    PubMed

    Kaye, Sherrie-Anne; White, Melanie J; Lewis, Ioni M

    2013-01-01

    Using Gray and McNaughton's (2000) revised reinforcement sensitivity theory (r-RST), we examined the influence of personality on processing of words presented in gain-framed and loss-framed anti-speeding messages and how the processing biases associated with personality influenced message acceptance. The r-RST predicts that the nervous system regulates personality and that behaviour is dependent upon the activation of the behavioural activation system (BAS), activated by reward cues and the fight-flight-freeze system (FFFS), activated by punishment cues. According to r-RST, individuals differ in the sensitivities of their BAS and FFFS (i.e., weak to strong), which in turn leads to stable patterns of behaviour in the presence of rewards and punishments, respectively. It was hypothesised that individual differences in personality (i.e., strength of the BAS and the FFFS) would influence the degree of both message processing (as measured by reaction time to previously viewed message words) and message acceptance (measured three ways by perceived message effectiveness, behavioural intentions, and attitudes). Specifically, it was anticipated that, individuals with a stronger BAS would process the words presented in the gain-frame messages faster than those with a weaker BAS and individuals with a stronger FFFS would process the words presented in the loss-frame messages faster than those with a weaker FFFS. Further, it was expected that greater processing (faster reaction times) would be associated with greater acceptance for that message. Driver licence holding students (N=108) were recruited to view one of four anti-speeding messages (i.e., social gain-frame, social loss-frame, physical gain-frame, and physical loss-frame). A computerised lexical decision task assessed participants' subsequent reaction times to message words, as an indicator of the extent of processing of the previously viewed message. Self-report measures assessed personality and the three message acceptance measures. As predicted, the degree of initial processing of the content of the social gain-framed message mediated the relationship between the reward sensitive trait and message effectiveness. Initial processing of the physical loss-framed message partially mediated the relationship between the punishment sensitive trait and both message effectiveness and behavioural intention ratings. These results show that reward sensitivity and punishment sensitivity traits influence cognitive processing of gain-framed and loss-framed message content, respectively, and subsequently, message effectiveness and behavioural intention ratings. Specifically, a range of road safety messages (i.e., gain-frame and loss-frame messages) could be designed which align with the processing biases associated with personality and which would target those individuals who are sensitive to rewards and those who are sensitive to punishments. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Simulations of VLBI observations of a geodetic satellite providing co-location in space

    NASA Astrophysics Data System (ADS)

    Anderson, James M.; Beyerle, Georg; Glaser, Susanne; Liu, Li; Männel, Benjamin; Nilsson, Tobias; Heinkelmann, Robert; Schuh, Harald

    2018-02-01

    We performed Monte Carlo simulations of very-long-baseline interferometry (VLBI) observations of Earth-orbiting satellites incorporating co-located space-geodetic instruments in order to study how well the VLBI frame and the spacecraft frame can be tied using such measurements. We simulated observations of spacecraft by VLBI observations, time-of-flight (TOF) measurements using a time-encoded signal in the spacecraft transmission, similar in concept to precise point positioning, and differential VLBI (D-VLBI) observations using angularly nearby quasar calibrators to compare their relative performance. We used the proposed European Geodetic Reference Antenna in Space (E-GRASP) mission as an initial test case for our software. We found that the standard VLBI technique is limited, in part, by the present lack of knowledge of the absolute offset of VLBI time to Coordinated Universal Time at the level of microseconds. TOF measurements are better able to overcome this problem and provide frame ties with uncertainties in translation and scale nearly a factor of three smaller than those yielded from VLBI measurements. If the absolute time offset issue can be resolved by external means, the VLBI results can be significantly improved and can come close to providing 1 mm accuracy in the frame tie parameters. D-VLBI observations with optimum performance assumptions provide roughly a factor of two higher uncertainties for the E-GRASP orbit. We additionally simulated how station and spacecraft position offsets affect the frame tie performance.

  2. Advances in x-ray framing cameras at the National Ignition Facility to improve quantitative precision in x-ray imaging

    DOE PAGES

    Benedetti, L. R.; Holder, J. P.; Perkins, M.; ...

    2016-02-26

    We describe an experimental method to measure the gate profile of an x-ray framing camera and to determine several important functional parameters: relative gain (between strips), relative gain droop (within each strip), gate propagation velocity, gate width, and actual inter-strip timing. Several of these parameters cannot be measured accurately by any other technique. This method is then used to document cross talk-induced gain variations and artifacts created by radiation that arrives before the framing camera is actively amplifying x-rays. Electromagnetic cross talk can cause relative gains to vary significantly as inter-strip timing is varied. This imposes a stringent requirement formore » gain calibration. If radiation arrives before a framing camera is triggered, it can cause an artifact that manifests as a high-intensity, spatially varying background signal. Furthermore, we have developed a device that can be added to the framing camera head to prevent these artifacts.« less

  3. The effects of frame, appeal, and outcome extremity of antismoking messages on cognitive processing.

    PubMed

    Leshner, Glenn; Cheng, I-Huei

    2009-04-01

    Research on the impact of antismoking advertisements in countermarketing cigarette advertising is equivocal. Although many studies examined how different message appeal types influence people's attitudes and behavior, there have been few studies that have explored the mechanism of how individuals attend to and remember antismoking information. This study examined how message attributes of antismoking TV ads (frame, appeal type, and outcome extremity) interacted to influence people's attention (secondary task reaction time) and memory (recognition). Antismoking public service announcements were chosen that were either loss- or gain-framed, had either a health or social appeal, or had either a more or less extreme outcome described in the message. Among the key findings were that loss-framed messages with more extreme outcomes required the most processing resources (i.e., had the slowest secondary task reaction times) and were the best remembered (i.e., were best recognized). These findings indicate ways that different message attributes affect individuals' cognitive processing, and they are discussed in light of prior framing and persuasion research.

  4. Advances in x-ray framing cameras at the National Ignition Facility to improve quantitative precision in x-ray imaging.

    PubMed

    Benedetti, L R; Holder, J P; Perkins, M; Brown, C G; Anderson, C S; Allen, F V; Petre, R B; Hargrove, D; Glenn, S M; Simanovskaia, N; Bradley, D K; Bell, P

    2016-02-01

    We describe an experimental method to measure the gate profile of an x-ray framing camera and to determine several important functional parameters: relative gain (between strips), relative gain droop (within each strip), gate propagation velocity, gate width, and actual inter-strip timing. Several of these parameters cannot be measured accurately by any other technique. This method is then used to document cross talk-induced gain variations and artifacts created by radiation that arrives before the framing camera is actively amplifying x-rays. Electromagnetic cross talk can cause relative gains to vary significantly as inter-strip timing is varied. This imposes a stringent requirement for gain calibration. If radiation arrives before a framing camera is triggered, it can cause an artifact that manifests as a high-intensity, spatially varying background signal. We have developed a device that can be added to the framing camera head to prevent these artifacts.

  5. Quantum reference frames and their applications to thermodynamics.

    PubMed

    Popescu, Sandu; Sainz, Ana Belén; Short, Anthony J; Winter, Andreas

    2018-07-13

    We construct a quantum reference frame, which can be used to approximately implement arbitrary unitary transformations on a system in the presence of any number of extensive conserved quantities, by absorbing any back action provided by the conservation laws. Thus, the reference frame at the same time acts as a battery for the conserved quantities. Our construction features a physically intuitive, clear and implementation-friendly realization. Indeed, the reference system is composed of the same types of subsystems as the original system and is finite for any desired accuracy. In addition, the interaction with the reference frame can be broken down into two-body terms coupling the system to one of the reference frame subsystems at a time. We apply this construction to quantum thermodynamic set-ups with multiple, possibly non-commuting conserved quantities, which allows for the definition of explicit batteries in such cases.This article is part of a discussion meeting issue 'Foundations of quantum mechanics and their impact on contemporary society'. © 2018 The Author(s).

  6. Validity and reproducibility of self-reported working hours among Japanese male employees

    PubMed Central

    Imai, Teppei; Kuwahara, Keisuke; Miyamoto, Toshiaki; Okazaki, Hiroko; Nishihara, Akiko; Kabe, Isamu; Mizoue, Tetsuya; Dohi, Seitaro

    2016-01-01

    Objective: Working long hours is a potential health hazard. Although self-reporting of working hours in various time frames has been used in epidemiologic studies, its validity is unclear. The objective of this study was to examine the validity and reproducibility of self-reported working hours among Japanese male employees. Methods: The participants were 164 male employees of four large-scale companies in Japan. For validity, the Spearman correlation between self-reported working hours in the second survey and the working hours recorded by the company was calculated for the following four time frames: daily working hours, monthly overtime working hours in the last month, average overtime working hours in the last 3 months, and the frequency of long working months (≥45 h/month) within the last 12 months. For reproducibility, the intraclass correlation between the first (September 2013) and second surveys (December 2013) was calculated for each of the four time frames. Results: The Spearman correlations between self-reported working hours and those based on company records were 0.74, 0.81, 0.85, and 0.89 for daily, monthly, 3-monthly, and yearly time periods, respectively. The intraclass correlations for self-reported working hours between the two questionnaire surveys were 0.63, 0.66, 0.73, and 0.87 for the respective time frames. Conclusions: The results of the present study among Japanese male employees suggest that the validity of self-reported working hours is high for all four time frames, whereas the reproducibility is moderate to high. PMID:27265530

  7. Improved frame-based estimation of head motion in PET brain imaging.

    PubMed

    Mukherjee, J M; Lindsay, C; Mukherjee, A; Olivier, P; Shao, L; King, M A; Licho, R

    2016-05-01

    Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. The list mode data for PET acquisition is uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type.

  8. Dynamic heart model for the mathematical cardiac torso (MCAT) phantom to represent the invariant total heart volume

    NASA Astrophysics Data System (ADS)

    Pretorius, P. H.; King, Michael A.; Tsui, Benjamin M.; LaCroix, Karen; Xia, Weishi

    1998-07-01

    This manuscript documents the alteration of the heart model of the MCAT phantom to better represent cardiac motion. The objective of the inclusion of motion was to develop a digital simulation of the heart such that the impact of cardiac motion on single photon emission computed tomography (SPECT) imaging could be assessed and methods of quantitating cardiac function could be investigated. The motion of the dynamic MCAT's heart is modeled by a 128 time frame volume curve. Eight time frames are averaged together to obtain a gated perfusion acquisition of 16 time frames and ensure motion within every time frame. The position of the MCAT heart was changed during contraction to rotate back and forth around the long axis through the center of the left ventricle (LV) using the end systolic time frame as turning point. Simple respiratory motion was also introduced by changing the orientation of the heart model in a 2 dimensional (2D) plane with every time frame. The averaging effect of respiratory motion in a specific time frame was modeled by randomly selecting multiple heart locations between two extreme orientations. Non-gated perfusion phantoms were also generated by averaging over all time frames. Maximal chamber volumes were selected to fit a profile of a normal healthy person. These volumes were changed during contraction of the ventricles such that the increase in volume in the atria compensated for the decrease in volume in the ventricles. The myocardium were modeled to represent shortening of muscle fibers during contraction with the base of the ventricles moving towards a static apex. The apical region was modeled with moderate wall thinning present while myocardial mass was conserved. To test the applicability of the dynamic heart model, myocardial wall thickening was measured using maximum counts and full width half maximum measurements, and compared with published trends. An analytical 3D projector, with attenuation and detector response included, was used to generate radionuclide projection data sets. After reconstruction a linear relationship was obtained between maximum myocardial counts and myocardium thickness, similar to published results. A numeric difference in values from different locations exist due to different amounts of attenuation present. Similar results were obtained for FWHM measurements. Also, a hot apical region on the polar maps without attenuation compensation turns into an apical defect with attenuation compensation. The apical decrease was more prominent in ED than ES due to the change in the partial volume effect. Both of these agree with clinical trends. It is concluded that the dynamic MCAT (dMCAT) phantom can be used to study the influence of various physical parameters on radionuclide perfusion imaging.

  9. Measuring exertion time, duty cycle and hand activity level for industrial tasks using computer vision.

    PubMed

    Akkas, Oguz; Lee, Cheng Hsien; Hu, Yu Hen; Harris Adamson, Carisa; Rempel, David; Radwin, Robert G

    2017-12-01

    Two computer vision algorithms were developed to automatically estimate exertion time, duty cycle (DC) and hand activity level (HAL) from videos of workers performing 50 industrial tasks. The average DC difference between manual frame-by-frame analysis and the computer vision DC was -5.8% for the Decision Tree (DT) algorithm, and 1.4% for the Feature Vector Training (FVT) algorithm. The average HAL difference was 0.5 for the DT algorithm and 0.3 for the FVT algorithm. A sensitivity analysis, conducted to examine the influence that deviations in DC have on HAL, found it remained unaffected when DC error was less than 5%. Thus, a DC error less than 10% will impact HAL less than 0.5 HAL, which is negligible. Automatic computer vision HAL estimates were therefore comparable to manual frame-by-frame estimates. Practitioner Summary: Computer vision was used to automatically estimate exertion time, duty cycle and hand activity level from videos of workers performing industrial tasks.

  10. Role of accentuation in the selection/rejection task framing effect.

    PubMed

    Chen, Jing; Proctor, Robert W

    2017-04-01

    Procedure invariance is a basic assumption of rational theories of choice, however, it has been shown to be violated: Different response modes, or task frames, sometimes reveal opposite preferences. The current study focused on selection and rejection task frames, involving a unique type of problem with enriched and impoverished options, which has previously led to conflicting findings and theoretical explanations: the compatibility hypothesis (Shafir, 1993) and the accentuation hypothesis (Wedell, 1997). We examined the role of task frame by distinguishing these 2 hypotheses and evaluating the information-processing basis of the choices. Experiments conducted online (Experiments 1 and 3) and in-lab (Experiment 4 with eye-tracking technique) revealed a difference between the 2 task frames in the choice data (i.e., the task-framing effect) as a function of the relative attractiveness of the options. Also, this task-framing effect was not influenced by imposed time constraints (Experiments 5 and 6) and was similarly evident with a more direct measure for the option attractiveness (obtained in Experiment 7). Experiment 2, conducted in a lab setting with verbal-protocol requirements, yielded no task-framing effect, suggesting that a requirement to verbalize reasons for choice minimizes accentuation. With this exception, the choice data are in agreement with the accentuation hypothesis, and the combined findings in choice, decision time, task confusion, and eye-tracking data provide evidence of a basis in cognitive effort rather than motivation, as Wedell proposed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  11. Navigating the field of temporally framed care in the Danish home care sector.

    PubMed

    Tufte, Pernille; Dahl, Hanne Marlene

    2016-01-01

    The organisational and temporal framing of elderly care in Europe has changed in the wake of new public management reforms and standardised care services, the strict measurement of time and work schedules have become central aspects of care work. The article investigates the crafting of care in this framing: how care workers approach the services specified in their rotas and navigate between needs, demands and opportunities in the daily performance of duties. Applying feminist theory on time and anthropological theory on social navigation, it examines the practice of home care work in two Danish municipalities. Data are derived predominantly from participant observation. The article identifies two overarching temporal dilemmas in different home care situations: one where process time prevails over clock time and another where the care workers balance the two. Focusing on how care workers respond to these dilemmas in practice, the article identifies various navigation tactics, including leaving time outside, individualised routinisation, working on different paths simultaneously and postponing tasks. By assessing care workers' performance in the temporal framing of work and focusing on care workers' mediation between different time logics, this study provides an in-depth perspective on the broader feminist literature on the dilemmas of care. © 2015 Foundation for the Sociology of Health & Illness.

  12. The Ingenious Theory of Interstellar Trade

    NASA Astrophysics Data System (ADS)

    Radhakrishnan, Arun; Ganapathy, Rohan M.

    This paper extends interplanetary trade theory to an interstellar setting. It is chiefly concerned with the following question: How should interest charges on goods in transit be computed when the goods travel at speeds close to the actual speed of light? This is a problem because the time taken in transit will appear less to an observer travelling with the goods than to a stationary observer. An innovative and ingenious solution is derived from the economic theory, and two useless but TRUE theorems are proved. The interstellar trade would happen in such a way that two time frames must be considered namely that of the stationary observer whose time runs faster compared to the time frame of the observer in transit The interest in a given trade is purely based on the time taken for the debtor to pay the amount, once the goods have been delivered by the seller. But, in case of interstellar trade, the interest to be calculated in between two time frames would lead to the question of which time frame to be considered and moreover, the time taken for the goods to reach the destination is signicantly prolonged compared to the interplanetary trade, which means, even the slightest variations in the interest rate would be magnied. Apart from this, various new factors arise while calculating the interest. The factors include the time value of money, and the risk of variation in demand for goods, the risk of interspace accidents causing loss of the goods and the rate of perish-ability in case of organic goods. The first two factors considered, for which the time frame of the stationary observer is considered and the factors such as the risk of accidents and the rate of perish-ability of the goods are considered based on the time frame of the observer in transit's point of view. The reasons for such considerations and various assumptions on these concepts are dealt in this paper. The theorems that are formulated in this paper would provide the interstellar traders a basic framework on the uniqueness of interstellar trading as opposed to the interplanetary trading. The paper would also tackle problems based on the computation of the perish-ability factor and the risk of variation in demand, as per special relativity. On the whole, a realistic approach based in the current trade policies and accounting standards is given, for a futurist trading spectrum.

  13. Why the Greenwich Meridian Moved

    DTIC Science & Technology

    2015-08-01

    that are related to the geocentric reference frame introduced by the Bureau International de l’Heure (BIH) in 1984. This BIHTerrestrial System provided...the basis for orientation of subsequent geocentric reference frames, including all realizations of theWorld Geodetic Sys- tem 1984 and the...astronomical time. The coordinates of satellite-navigation receivers are provided in reference frames that are related to the geocentric reference

  14. Postoperative Stereotactic Radiosurgery Without Whole-Brain Radiation Therapy for Brain Metastases: Potential Role of Preoperative Tumor Size

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartford, Alan C., E-mail: Alan.C.Hartford@Hitchcock.org; Paravati, Anthony J.; Spire, William J.

    2013-03-01

    Purpose: Radiation therapy following resection of a brain metastasis increases the probability of disease control at the surgical site. We analyzed our experience with postoperative stereotactic radiosurgery (SRS) as an alternative to whole-brain radiotherapy (WBRT), with an emphasis on identifying factors that might predict intracranial disease control and overall survival (OS). Methods and Materials: We retrospectively reviewed all patients through December 2008, who, after surgical resection, underwent SRS to the tumor bed, deferring WBRT. Multiple factors were analyzed for time to intracranial recurrence (ICR), whether local recurrence (LR) at the surgical bed or “distant” recurrence (DR) in the brain, formore » time to WBRT, and for OS. Results: A total of 49 lesions in 47 patients were treated with postoperative SRS. With median follow-up of 9.3 months (range, 1.1-61.4 months), local control rates at the resection cavity were 85.5% at 1 year and 66.9% at 2 years. OS rates at 1 and 2 years were 52.5% and 31.7%, respectively. On univariate analysis (preoperative) tumors larger than 3.0 cm exhibited a significantly shorter time to LR. At a cutoff of 2.0 cm, larger tumors resulted in significantly shorter times not only for LR but also for DR, ICR, and salvage WBRT. While multivariate Cox regressions showed preoperative size to be significant for times to DR, ICR, and WBRT, in similar multivariate analysis for OS, only the graded prognostic assessment proved to be significant. However, the number of intracranial metastases at presentation was not significantly associated with OS nor with other outcome variables. Conclusions: Larger tumor size was associated with shorter time to recurrence and with shorter time to salvage WBRT; however, larger tumors were not associated with decrements in OS, suggesting successful salvage. SRS to the tumor bed without WBRT is an effective treatment for resected brain metastases, achieving local control particularly for tumors up to 3.0 cm diameter.« less

  15. Resin Flow Behavior Simulation of Grooved Foam Sandwich Composites with the Vacuum Assisted Resin Infusion (VARI) Molding Process

    PubMed Central

    Zhao, Chenhui; Zhang, Guangcheng; Wu, Yibo

    2012-01-01

    The resin flow behavior in the vacuum assisted resin infusion molding process (VARI) of foam sandwich composites was studied by both visualization flow experiments and computer simulation. Both experimental and simulation results show that: the distribution medium (DM) leads to a shorter molding filling time in grooved foam sandwich composites via the VARI process, and the mold filling time is linearly reduced with the increase of the ratio of DM/Preform. Patterns of the resin sources have a significant influence on the resin filling time. The filling time of center source is shorter than that of edge pattern. Point pattern results in longer filling time than of linear source. Short edge/center patterns need a longer time to fill the mould compared with Long edge/center sources.

  16. Electronic mail was not better than postal mail for surveying residents and faculty.

    PubMed

    Akl, Elie A; Maroun, Nancy; Klocke, Robert A; Montori, Victor; Schünemann, Holger J

    2005-04-01

    To compare response rate, time to response, and data quality of electronic and postal surveys in the setting of postgraduate medical education. A randomized controlled trial in a university-based internal medicine residency program. We randomized 119 residents and 83 faculty to an electronic versus a postal survey with up to two reminders and measured response rate, time to response, and data quality. For residents, the e-survey resulted in a lower response rate than the postal survey (63.3% versus 79.7%; difference -16.3%, 95% confidence interval (95% CI) -32.3% to -0.4%%; P=.049), but a shorter mean response time, by 3.8 days (95% CI 0.2-7.4; P=.042). For faculty, the e-survey did not result in a significantly lower response rate than the postal survey (85.4% vs. 81.0%; difference 4.4%, 95% CI -11.7 to 20.5%; P=.591), but resulted in a shorter average response time, by 8.4 days (95% CI 4.4 to 12.4; P < 0.001). There were no differences in the quality of data or responses to the survey between the two methods. E-surveys were not superior to postal surveys in terms of response rate, but resulted in shorter time to response and equivalent data quality.

  17. Optical cell tracking analysis using a straight-forward approach to minimize processing time for high frame rate data

    NASA Astrophysics Data System (ADS)

    Seeto, Wen Jun; Lipke, Elizabeth Ann

    2016-03-01

    Tracking of rolling cells via in vitro experiment is now commonly performed using customized computer programs. In most cases, two critical challenges continue to limit analysis of cell rolling data: long computation times due to the complexity of tracking algorithms and difficulty in accurately correlating a given cell with itself from one frame to the next, which is typically due to errors caused by cells that either come close in proximity to each other or come in contact with each other. In this paper, we have developed a sophisticated, yet simple and highly effective, rolling cell tracking system to address these two critical problems. This optical cell tracking analysis (OCTA) system first employs ImageJ for cell identification in each frame of a cell rolling video. A custom MATLAB code was written to use the geometric and positional information of all cells as the primary parameters for matching each individual cell with itself between consecutive frames and to avoid errors when tracking cells that come within close proximity to one another. Once the cells are matched, rolling velocity can be obtained for further analysis. The use of ImageJ for cell identification eliminates the need for high level MATLAB image processing knowledge. As a result, only fundamental MATLAB syntax is necessary for cell matching. OCTA has been implemented in the tracking of endothelial colony forming cell (ECFC) rolling under shear. The processing time needed to obtain tracked cell data from a 2 min ECFC rolling video recorded at 70 frames per second with a total of over 8000 frames is less than 6 min using a computer with an Intel® Core™ i7 CPU 2.80 GHz (8 CPUs). This cell tracking system benefits cell rolling analysis by substantially reducing the time required for post-acquisition data processing of high frame rate video recordings and preventing tracking errors when individual cells come in close proximity to one another.

  18. Adaptation of hidden Markov models for recognizing speech of reduced frame rate.

    PubMed

    Lee, Lee-Min; Jean, Fu-Rong

    2013-12-01

    The frame rate of the observation sequence in distributed speech recognition applications may be reduced to suit a resource-limited front-end device. In order to use models trained using full-frame-rate data in the recognition of reduced frame-rate (RFR) data, we propose a method for adapting the transition probabilities of hidden Markov models (HMMs) to match the frame rate of the observation. Experiments on the recognition of clean and noisy connected digits are conducted to evaluate the proposed method. Experimental results show that the proposed method can effectively compensate for the frame-rate mismatch between the training and the test data. Using our adapted model to recognize the RFR speech data, one can significantly reduce the computation time and achieve the same level of accuracy as that of a method, which restores the frame rate using data interpolation.

  19. Theory, implementation and applications of nonstationary Gabor frames

    PubMed Central

    Balazs, P.; Dörfler, M.; Jaillet, F.; Holighaus, N.; Velasco, G.

    2011-01-01

    Signal analysis with classical Gabor frames leads to a fixed time–frequency resolution over the whole time–frequency plane. To overcome the limitations imposed by this rigidity, we propose an extension of Gabor theory that leads to the construction of frames with time–frequency resolution changing over time or frequency. We describe the construction of the resulting nonstationary Gabor frames and give the explicit formula for the canonical dual frame for a particular case, the painless case. We show that wavelet transforms, constant-Q transforms and more general filter banks may be modeled in the framework of nonstationary Gabor frames. Further, we present the results in the finite-dimensional case, which provides a method for implementing the above-mentioned transforms with perfect reconstruction. Finally, we elaborate on two applications of nonstationary Gabor frames in audio signal processing, namely a method for automatic adaptation to transients and an algorithm for an invertible constant-Q transform. PMID:22267893

  20. Serial changes of humor comprehension for four-frame comic Manga: an fMRI study.

    PubMed

    Osaka, Mariko; Yaoi, Ken; Minamoto, Takehiro; Osaka, Naoyuki

    2014-07-25

    Serial changes of humor comprehension evoked by a well organized four-frame comic Manga were investigated by fMRI in each step of humor comprehension. The neural substrates underlying the amusing effects in response to funny and mixed order manga were compared. In accordance with the time course of the four frames, fMRI activations changed serially. Beginning with the second frame (development scene), activation of the temporo-parietal junction (TPJ) was observed, followed by activations in the temporal and frontal areas during viewing of the third frame (turn scene). For the fourth frame (punch line), strong increased activations were confirmed in the medial prefrontal cortex (MPFC) and cerebellum. Interestingly, distinguishable activation differences in the cerebellum between funny and non-funny conditions were also found for the fourth frame. These findings suggest that humor comprehension evokes activation that initiates in the TPJ and expands to the MPFC and cerebellum at the convergence level.

  1. Gelatin-thrombin hemostatic matrix in neurosurgical procedures: hemostasis effectiveness and economic value of clinical and surgical procedure-related benefits.

    PubMed

    Esposito, Felice; Cappabianca, Paolo; Angileri, Filippo F; Cavallo, Luigi M; Priola, Stefano M; Crimi, Salvatore; Solari, Domenico; Germanò, Antonino F; Tomasello, Francesco

    2016-07-26

    Gelatin-thrombin hemostatic matrix (FloSeal®) use is associated with shorter surgical times and less blood loss, parameters that are highly valued in neurosurgical procedures. We aimed to assess the effectiveness of gelatin-thrombin in neurosurgical procedures and estimate its economic value. In a 6-month retrospective evaluation at 2 hospitals, intraoperative and postoperative information were collected from patients undergoing neurosurgical procedures where bleeding was controlled with gelatin-thrombin matrix or according to local bleeding control guidelines (control group). Study endpoints were: length of surgery, estimated blood loss, hospitalization duration, blood units utilized, intensive care unit days, postoperative complications, and time-to-recovery. Statistical methods compared endpoints between the gelatin-thrombin and control groups and resource utilization costs were estimated. Seventy-eight patients (38 gelatin-thrombin; 40 control) were included. Gelatin-thrombin was associated with a shorter surgery duration than control 166±40 versus 185±55, p=0.0839); a lower estimated blood loss (185±80 versus 250±95ml; p=0.0017); a shorter hospital stay (10±3 versus 13±3 days; p<0.001); fewer intensive care unit days (10 days/3 patients and 20 days/4 patients); and shorter time-to-recovery (3±2.2 versus 4±2.8 weeks; p=0861). Fewer gelatin-thrombin patients experienced postoperative complications (3 minor) than the control group (5 minor; 3 major). No gelatin-thrombin patient required blood transfusion; 5 units were administered in the control group. The cost of gelatin-thrombin (€268.40/unit) was offset by the shorter surgery duration (difference of 19 minutes at €858 per hour) and the economic value of improved the other endpoint outcomes (ie, shorter hospital stay, less blood loss/lack of need for transfusion, fewer intensive care unit days, and complications). Gelatin-thrombin hemostatic matrix use in patients undergoing neurosurgical procedures was associated with better intra- and post-operative parameters than conventional hemostasis methods, with these parameters having substantial economic benefits.

  2. Perceiving Event Dynamics and Parsing Hollywood Films

    ERIC Educational Resources Information Center

    Cutting, James E.; Brunick, Kaitlin L.; Candan, Ayse

    2012-01-01

    We selected 24 Hollywood movies released from 1940 through 2010 to serve as a film corpus. Eight viewers, three per film, parsed them into events, which are best termed subscenes. While watching a film a second time, viewers scrolled through frames and recorded the frame number where each event began. Viewers agreed about 90% of the time. We then…

  3. 42 CFR 405.1016 - Time frames for deciding an appeal before an ALJ.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 2 2011-10-01 2011-10-01 false Time frames for deciding an appeal before an ALJ. 405.1016 Section 405.1016 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH..., Redeterminations, Reconsiderations, and Appeals Under Original Medicare (Part A and Part B) Alj Hearings § 405.1016...

  4. 42 CFR 405.1016 - Time frames for deciding an appeal before an ALJ.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Time frames for deciding an appeal before an ALJ. 405.1016 Section 405.1016 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH..., Redeterminations, Reconsiderations, and Appeals Under Original Medicare (Part A and Part B) Alj Hearings § 405.1016...

  5. Speech coding, reconstruction and recognition using acoustics and electromagnetic waves

    DOEpatents

    Holzrichter, J.F.; Ng, L.C.

    1998-03-17

    The use of EM radiation in conjunction with simultaneously recorded acoustic speech information enables a complete mathematical coding of acoustic speech. The methods include the forming of a feature vector for each pitch period of voiced speech and the forming of feature vectors for each time frame of unvoiced, as well as for combined voiced and unvoiced speech. The methods include how to deconvolve the speech excitation function from the acoustic speech output to describe the transfer function each time frame. The formation of feature vectors defining all acoustic speech units over well defined time frames can be used for purposes of speech coding, speech compression, speaker identification, language-of-speech identification, speech recognition, speech synthesis, speech translation, speech telephony, and speech teaching. 35 figs.

  6. Speech coding, reconstruction and recognition using acoustics and electromagnetic waves

    DOEpatents

    Holzrichter, John F.; Ng, Lawrence C.

    1998-01-01

    The use of EM radiation in conjunction with simultaneously recorded acoustic speech information enables a complete mathematical coding of acoustic speech. The methods include the forming of a feature vector for each pitch period of voiced speech and the forming of feature vectors for each time frame of unvoiced, as well as for combined voiced and unvoiced speech. The methods include how to deconvolve the speech excitation function from the acoustic speech output to describe the transfer function each time frame. The formation of feature vectors defining all acoustic speech units over well defined time frames can be used for purposes of speech coding, speech compression, speaker identification, language-of-speech identification, speech recognition, speech synthesis, speech translation, speech telephony, and speech teaching.

  7. Bounce universe from string-inspired Gauss-Bonnet gravity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bamba, Kazuharu; Makarenko, Andrey N.; Myagky, Alexandr N.

    2015-04-01

    We explore cosmology with a bounce in Gauss-Bonnet gravity where the Gauss-Bonnet invariant couples to a dynamical scalar field. In particular, the potential and and Gauss-Bonnet coupling function of the scalar field are reconstructed so that the cosmological bounce can be realized in the case that the scale factor has hyperbolic and exponential forms. Furthermore, we examine the relation between the bounce in the string (Jordan) and Einstein frames by using the conformal transformation between these conformal frames. It is shown that in general, the property of the bounce point in the string frame changes after the frame is movedmore » to the Einstein frame. Moreover, it is found that at the point in the Einstein frame corresponding to the point of the cosmological bounce in the string frame, the second derivative of the scale factor has an extreme value. In addition, it is demonstrated that at the time of the cosmological bounce in the Einstein frame, there is the Gauss-Bonnet coupling function of the scalar field, although it does not exist in the string frame.« less

  8. Parallel Key Frame Extraction for Surveillance Video Service in a Smart City.

    PubMed

    Zheng, Ran; Yao, Chuanwei; Jin, Hai; Zhu, Lei; Zhang, Qin; Deng, Wei

    2015-01-01

    Surveillance video service (SVS) is one of the most important services provided in a smart city. It is very important for the utilization of SVS to provide design efficient surveillance video analysis techniques. Key frame extraction is a simple yet effective technique to achieve this goal. In surveillance video applications, key frames are typically used to summarize important video content. It is very important and essential to extract key frames accurately and efficiently. A novel approach is proposed to extract key frames from traffic surveillance videos based on GPU (graphics processing units) to ensure high efficiency and accuracy. For the determination of key frames, motion is a more salient feature in presenting actions or events, especially in surveillance videos. The motion feature is extracted in GPU to reduce running time. It is also smoothed to reduce noise, and the frames with local maxima of motion information are selected as the final key frames. The experimental results show that this approach can extract key frames more accurately and efficiently compared with several other methods.

  9. Comparison of Stereotactic and Ultrasound-guided Biopsy of Solid Supratentorial Tumor: A Preliminary Report

    PubMed Central

    Satyarthee, Guru Dutta; Chandra, P. Sarat; Sharma, Bhawani S.; Mehta, V. S.

    2017-01-01

    Introduction: The computed tomography (CT) guided stereotactic biopsy (STB) is considered as method of choice for biopsy of intracranial mass lesions. However, it's disadvantages are frame fixation, time requirement for transportation between CT scan suit to the operation theater with added much higher equipment cost in the relatively resource scarred developing country. Ultrasound-guided biopsy (USGB) is relatively simpler, economical, less time consuming, and real-time procedure. Clinical Materials and Methods: Thirty-seven consecutively admitted patients with supratentorial brain tumors, who underwent biopsy of the lesion using CT compatible stereotactic and ultrasound-guided (USGB) procedure formed cohort of the study. Based on location and size of the lesions, the cases were divided into two groups, superficial and deep. Twenty-two patients underwent ultrasound-guided biopsy and 15 with STB. Results: The diagnostic yield of STB was 93% and 91% for ultrasound-guided biopsy. The mean operation time of STB group was 149.00 min and 94 min for USGB, which was statistically significant. Two cases in each group developed hematoma; however, one case in USGB group needed surgical evacuation. The real-time monitoring detected two hematoma intraoperatively, which were further also confirmed on postoperative CT scan head. Conclusions: The ultrasound-guided biopsy procedure (USGB) was simple, relatively shorter time-consuming procedure and equally efficacious and utilizing economical equipment and can act as a safer alternative to CT STB process for biopsy of the intracranial mass lesion. Furthermore, USGB also provided intra-operative real-time monitoring, which provided clue for close monitoring in the postoperative period after completion of biopsy to look for development of fresh hematoma development not only at the biopsy site but also along the biopsy track and adjoining area. Perhaps, a longer period of ultrasonic monitoring following the procedure would be of greater help to detect hematoma formation, which is one of the most common complications of the biopsy procedure. PMID:29114280

  10. Multilingual Connotation Frames: A Case Study on Social Media for Targeted Sentiment Analysis and Forecast

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rashkin, Hannah J.; Bell, Eric B.; Choi, Yejin

    People around the globe respond to major real world events through social media. To study targeted public sentiments across many languages and geographic locations, we introduce multilingual connotation frames: an extension from English connotation frames of Rashkin et al. (2016) with 10 additional European languages, focusing on the implied sentiments among event participants engaged in a frame. As a case study, we present large scale analysis on targeted public sentiments using 1.2 million multilingual connotation frames extracted from Twitter. We rely on connotation frames to build models to forecast country-specific connotation dynamics – perspective change over time towards salient entitiesmore » and events. Our results demonstrate that connotation dynamics can be accurately predicted up to half a week in advance.« less

  11. Frame average optimization of cine-mode EPID images used for routine clinical in vivo patient dose verification of VMAT deliveries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCowan, P. M., E-mail: pmccowan@cancercare.mb.ca; McCurdy, B. M. C.; Medical Physics Department, CancerCare Manitoba, 675 McDermot Avenue, Winnipeg, Manitoba R3E 0V9

    Purpose: The in vivo 3D dose delivered to a patient during volumetric modulated arc therapy (VMAT) delivery can be calculated using electronic portal imaging device (EPID) images. These images must be acquired in cine-mode (i.e., “movie” mode) in order to capture the time-dependent delivery information. The angle subtended by each cine-mode EPID image during an arc can be changed via the frame averaging number selected within the image acquisition software. A large frame average number will decrease the EPID’s angular resolution and will result in a decrease in the accuracy of the dose information contained within each image. Alternatively, lessmore » EPID images acquired per delivery will decrease the overall 3D patient dose calculation time, which is appealing for large-scale clinical implementation. Therefore, the purpose of this study was to determine the optimal frame average value per EPID image, defined as the highest frame averaging that can be used without an appreciable loss in 3D dose reconstruction accuracy for VMAT treatments. Methods: Six different VMAT plans and six different SBRT-VMAT plans were delivered to an anthropomorphic phantom. Delivery was carried out on a Varian 2300ix model linear accelerator (Linac) equipped with an aS1000 EPID running at a frame acquisition rate of 7.5 Hz. An additional PC was set up at the Linac console area, equipped with specialized frame-grabber hardware and software packages allowing continuous acquisition of all EPID frames during delivery. Frames were averaged into “frame-averaged” EPID images using MATLAB. Each frame-averaged data set was used to calculate the in vivo dose to the patient and then compared to the single EPID frame in vivo dose calculation (the single frame calculation represents the highest possible angular resolution per EPID image). A mean percentage dose difference of low dose (<20% prescription dose) and high dose regions (>80% prescription dose) was calculated for each frame averaged scenario for each plan. The authors defined their unacceptable loss of accuracy as no more than a ±1% mean dose difference in the high dose region. Optimal frame average numbers were then determined as a function of the Linac’s average gantry speed and the dose per fraction. Results: The authors found that 9 and 11 frame averages were suitable for all VMAT and SBRT-VMAT treatments, respectively. This resulted in no more than a 1% loss to any of the dose region’s mean percentage difference when compared to the single frame reconstruction. The optimized number was dependent on the treatment’s dose per fraction and was determined to be as high as 14 for 12 Gy/fraction (fx), 15 for 8 Gy/fx, 11 for 6 Gy/fx, and 9 for 2 Gy/fx. Conclusions: The authors have determined an optimal EPID frame averaging number for multiple VMAT-type treatments. These are given as a function of the dose per fraction and average gantry speed. These optimized values are now used in the authors’ clinical, 3D, in vivo patient dosimetry program. This provides a reduction in calculation time while maintaining the authors’ required level of accuracy in the dose reconstruction.« less

  12. Temporal Consequences, Message Framing, and Consideration of Future Consequences: Persuasion Effects on Adult Fruit Intake Intention and Resolve.

    PubMed

    de Bruijn, Gert-Jan; Budding, Jeen

    2016-08-01

    Message framing is a persuasive strategy that has seen mixed evidence for promoting fruit intake intentions, potentially because framed messages for fruit intake have not (a) explicitly compared short-term consequences versus long-term consequences, (b) considered individual-level differences in time perspective, and (c) used alternative measures of fruit intake intentions. In the present online study, the effects of persuasive messages created from temporal context (short term vs. long term) and message frame (gain framed vs. loss framed) were investigated on fruit intake intentions and resolve among a sample of Dutch adults who were categorized as either present oriented or future oriented. For intention and resolve, results showed a significant Type of Frame × Type of Temporal Context interaction, such that gain-framed messages were more persuasive when combined with long-term consequences and loss-framed messages were more persuasive when combined with short-term consequences. The effect sizes for these differences were similar for resolve and intention, but only differences for intentions were significant. No other effects were found. These results demonstrate that message framing theory may usefully consider the inclusion of temporal context of outcomes and alternative motivation measures to maximize their persuasive effects.

  13. Flexible nuclear medicine camera and method of using

    DOEpatents

    Dilmanian, F.A.; Packer, S.; Slatkin, D.N.

    1996-12-10

    A nuclear medicine camera and method of use photographically record radioactive decay particles emitted from a source, for example a small, previously undetectable breast cancer, inside a patient. The camera includes a flexible frame containing a window, a photographic film, and a scintillation screen, with or without a gamma-ray collimator. The frame flexes for following the contour of the examination site on the patient, with the window being disposed in substantially abutting contact with the skin of the patient for reducing the distance between the film and the radiation source inside the patient. The frame is removably affixed to the patient at the examination site for allowing the patient mobility to wear the frame for a predetermined exposure time period. The exposure time may be several days for obtaining early qualitative detection of small malignant neoplasms. 11 figs.

  14. The Effective Fracture Toughness of Aluminum at Rapid Heating Rates.

    DTIC Science & Technology

    1987-12-01

    Stress Versus Time Relation During Test Under HWdraulic (Tinius-Olsen) Loading Device 32 11. Creep Rupture Tester ( SATEC ) Drawing ...... 33 12. SEN...1B7 Machine Corp Creep Frame SATEC C C-3053-P 12,000 Load Cell MTS 661.20A 271 5500 lb .02% Load Cell Interface 1220BF 34279B 25000 lb 1.6% Extenso- MIS... SATEC creep frame. A drawing of the creep frame can be seen in Figure 11. The samples were placed in the frame and the dead weight load was applied

  15. Hemodialysis

    MedlinePlus

    ... center, hemodialysis is usually done 3 times per week for about 4 hours at a time. People who choose to do ... at home may do dialysis treatment more frequently, 4-7 times per week for shorter hours each time. Your doctor will give you a ...

  16. Enhancement Strategies for Frame-To Uas Stereo Visual Odometry

    NASA Astrophysics Data System (ADS)

    Kersten, J.; Rodehorst, V.

    2016-06-01

    Autonomous navigation of indoor unmanned aircraft systems (UAS) requires accurate pose estimations usually obtained from indirect measurements. Navigation based on inertial measurement units (IMU) is known to be affected by high drift rates. The incorporation of cameras provides complementary information due to the different underlying measurement principle. The scale ambiguity problem for monocular cameras is avoided when a light-weight stereo camera setup is used. However, also frame-to-frame stereo visual odometry (VO) approaches are known to accumulate pose estimation errors over time. Several valuable real-time capable techniques for outlier detection and drift reduction in frame-to-frame VO, for example robust relative orientation estimation using random sample consensus (RANSAC) and bundle adjustment, are available. This study addresses the problem of choosing appropriate VO components. We propose a frame-to-frame stereo VO method based on carefully selected components and parameters. This method is evaluated regarding the impact and value of different outlier detection and drift-reduction strategies, for example keyframe selection and sparse bundle adjustment (SBA), using reference benchmark data as well as own real stereo data. The experimental results demonstrate that our VO method is able to estimate quite accurate trajectories. Feature bucketing and keyframe selection are simple but effective strategies which further improve the VO results. Furthermore, introducing the stereo baseline constraint in pose graph optimization (PGO) leads to significant improvements.

  17. 3-D ultrasound volume reconstruction using the direct frame interpolation method.

    PubMed

    Scheipers, Ulrich; Koptenko, Sergei; Remlinger, Rachel; Falco, Tony; Lachaine, Martin

    2010-11-01

    A new method for 3-D ultrasound volume reconstruction using tracked freehand 3-D ultrasound is proposed. The method is based on solving the forward volume reconstruction problem using direct interpolation of high-resolution ultrasound B-mode image frames. A series of ultrasound B-mode image frames (an image series) is acquired using the freehand scanning technique and position sensing via optical tracking equipment. The proposed algorithm creates additional intermediate image frames by directly interpolating between two or more adjacent image frames of the original image series. The target volume is filled using the original frames in combination with the additionally constructed frames. Compared with conventional volume reconstruction methods, no additional filling of empty voxels or holes within the volume is required, because the whole extent of the volume is defined by the arrangement of the original and the additionally constructed B-mode image frames. The proposed direct frame interpolation (DFI) method was tested on two different data sets acquired while scanning the head and neck region of different patients. The first data set consisted of eight B-mode 2-D frame sets acquired under optimal laboratory conditions. The second data set consisted of 73 image series acquired during a clinical study. Sample volumes were reconstructed for all 81 image series using the proposed DFI method with four different interpolation orders, as well as with the pixel nearest-neighbor method using three different interpolation neighborhoods. In addition, volumes based on a reduced number of image frames were reconstructed for comparison of the different methods' accuracy and robustness in reconstructing image data that lies between the original image frames. The DFI method is based on a forward approach making use of a priori information about the position and shape of the B-mode image frames (e.g., masking information) to optimize the reconstruction procedure and to reduce computation times and memory requirements. The method is straightforward, independent of additional input or parameters, and uses the high-resolution B-mode image frames instead of usually lower-resolution voxel information for interpolation. The DFI method can be considered as a valuable alternative to conventional 3-D ultrasound reconstruction methods based on pixel or voxel nearest-neighbor approaches, offering better quality and competitive reconstruction time.

  18. Impact of Submesoscale Processes on Dynamics of Phytoplankton Filaments

    DTIC Science & Technology

    2015-02-12

    submesoscale processes on the formation of chlorophyll a filaments during late springearlier summer, and late summer time frames. We show that during...the late summer time frame, ASC leads to the development of filaments with high values of chlorophyll a concentration along the edge of the cold jet...in contrast to the earlier summer time, when the ASC mixes phytoplankton much deeper to the area below of the euphotic depth, and chlorophyll a

  19. Predictors of lapse in first week of smoking abstinence in PTSD and non-PTSD smokers.

    PubMed

    Beckham, Jean C; Calhoun, Patrick S; Dennis, Michelle F; Wilson, Sarah M; Dedert, Eric A

    2013-06-01

    Retrospective research suggests smokers with posttraumatic stress disorder (PTSD) lapse more quickly after their quit date. Ecological momentary assessment (EMA) research is needed to confirm the presence of early smoking lapse in PTSD and form conceptualizations that inform intervention. Smokers with (n = 55) and without (n = 52) PTSD completed alarm-prompted EMA of situational and psychiatric variables the week before and after a quit date, and self-initiated EMA following smoking lapses. Blood samples at baseline and on the quit date allowed assessment of dehydroepiandrosterone (DHEA) and dehydroepiandrosterone sulfate (DHEA(S)). PTSD was related to shorter time to lapse (hazard ratio [HR] = 1.677, 95% CI: 1.106-2.544). Increased smoking abstinence self-efficacy was related to longer time to lapse (HR = 0.608, 95% CI: 0.430-0.860). Analyses of participants' real-time reports revealed that smokers with PTSD were more likely to attribute first-time lapses to negative affect ( = 5.412, p = .020), and trauma reminders (Fisher's exact p = .003**). Finally, the quit date decrease in DHEA(S) was related to shorter time to lapse (HR = 1.009, 95% CI: 1.000-1.018, p < .05). Results provide evidence of shorter time to first smoking lapse in PTSD, and add to evidence that early lapse occasions are more strongly related to trauma reminders, negative affect, and cravings in smokers with PTSD.

  20. Retention time alignment of LC/MS data by a divide-and-conquer algorithm.

    PubMed

    Zhang, Zhongqi

    2012-04-01

    Liquid chromatography-mass spectrometry (LC/MS) has become the method of choice for characterizing complex mixtures. These analyses often involve quantitative comparison of components in multiple samples. To achieve automated sample comparison, the components of interest must be detected and identified, and their retention times aligned and peak areas calculated. This article describes a simple pairwise iterative retention time alignment algorithm, based on the divide-and-conquer approach, for alignment of ion features detected in LC/MS experiments. In this iterative algorithm, ion features in the sample run are first aligned with features in the reference run by applying a single constant shift of retention time. The sample chromatogram is then divided into two shorter chromatograms, which are aligned to the reference chromatogram the same way. Each shorter chromatogram is further divided into even shorter chromatograms. This process continues until each chromatogram is sufficiently narrow so that ion features within it have a similar retention time shift. In six pairwise LC/MS alignment examples containing a total of 6507 confirmed true corresponding feature pairs with retention time shifts up to five peak widths, the algorithm successfully aligned these features with an error rate of 0.2%. The alignment algorithm is demonstrated to be fast, robust, fully automatic, and superior to other algorithms. After alignment and gap-filling of detected ion features, their abundances can be tabulated for direct comparison between samples.

  1. Sutureless versus Conventional Aortic Valve Replacement: Outcomes in 70 High-Risk Patients Undergoing Concomitant Cardiac Procedures.

    PubMed

    Hanedan, Muhammet Onur; Yuruk, Mehmet Ali; Parlar, Ali Ihsan; Ziyrek, Ugur; Arslan, Ali Kemal; Sayar, Ufuk; Mataraci, Ilker

    2018-02-01

    In elderly, high-risk surgical patients, sutureless aortic valve replacement (AVR) can often be an alternative to conventional AVR; shorter aortic cross-clamp and cardiopulmonary bypass times are the chief advantages. We compared the outcomes of sutureless AVR with those of conventional AVR in 70 elderly patients who underwent concomitant cardiac surgical procedures. We retrospectively analyzed the cases of 42 men and 28 women (mean age, 70.4 ± 10.3 yr; range, 34-93 yr) who underwent cardiac operations plus AVR with either a sutureless valve (group 1, n=38) or a conventional bioprosthetic or mechanical valve (group 2, n=32). Baseline patient characteristics were similar except for worse New York Heart Association functional status and the prevalence of diabetes mellitus in group 1. In group 1, the operative, cross-clamp, and cardiopulmonary bypass times were shorter (all P =0.001), postoperative drainage amounts were lower ( P =0.009), hospital stays were shorter ( P =0.004), and less red blood cell transfusion was needed ( P =0.037). Echocardiograms before patients' discharge from the hospital showed lower peak and mean aortic gradients in group 1 (mean transvalvular gradient, 8.4 ± 2.8 vs 12.2 ± 5.2 mmHg; P =0.012). We found that elderly, high-risk patients who underwent multiple cardiac surgical procedures and sutureless AVR had better hemodynamic outcomes and shorter ischemic times than did patients who underwent conventional AVR.

  2. Concurrent schedules of wheel-running reinforcement: choice between different durations of opportunity to run in rats.

    PubMed

    Belke, Terry W

    2006-02-01

    How do animals choose between opportunities to run of different durations? Are longer durations preferred over shorter durations because they permit a greater number of revolutions? Are shorter durations preferred because they engender higher rates of running? Will longer durations be chosen because running is less constrained? The present study reports on three experiments that attempted to address these questions. In the first experiment, five male Wistar rats chose between 10-sec and 50-sec opportunities to run on modified concurrent variable-interval (VI) schedules. Across conditions, the durations associated with the alternatives were reversed. Response, time, and reinforcer proportions did not vary from indifference. In a second experiment, eight female Long-Evans rats chose between opportunities to run of equal (30 sec) and unequal durations (10 sec and 50 sec) on concurrent variable-ratio (VR) schedules. As in Experiment 1, between presentations of equal duration conditions, 10-sec and 50-sec durations were reversed. Results showed that response, time, and reinforcer proportions on an alternative did not vary with reinforcer duration. In a third experiment, using concurrent VR schedules, durations were systematically varied to decrease the shorter duration toward 0 sec. As the shorter duration decreased, response, time, and reinforcer proportions shifted toward the longer duration. In summary, differences in durations of opportunities to run did not affect choice behavior in a manner consistent with the assumption that a longer reinforcer is a larger reinforcer.

  3. Sequential detection of web defects

    DOEpatents

    Eichel, Paul H.; Sleefe, Gerard E.; Stalker, K. Terry; Yee, Amy A.

    2001-01-01

    A system for detecting defects on a moving web having a sequential series of identical frames uses an imaging device to form a real-time camera image of a frame and a comparitor to comparing elements of the camera image with corresponding elements of an image of an exemplar frame. The comparitor provides an acceptable indication if the pair of elements are determined to be statistically identical; and a defective indication if the pair of elements are determined to be statistically not identical. If the pair of elements is neither acceptable nor defective, the comparitor recursively compares the element of said exemplar frame with corresponding elements of other frames on said web until one of the acceptable or defective indications occur.

  4. Software Process Automation: Interviews, Survey, and Workshop Results.

    DTIC Science & Technology

    1997-10-01

    International Business Machines Coproration Foundation is a pending trademark of Foundation Software , Inc. FrameMaker is a registered trademark of Adobe, Inc...amount of technology Integration of technologies, con- flicting points of view between adopting org. and consultants E CM FrameMaker Labor/resource...Weaver FrameMaker , CM System Integration of CM tool L InConcert Cadre, AutoPlan, DBStar Ineffective process integration, poor training, time

  5. Numerical Algorithms for Precise and Efficient Orbit Propagation and Positioning

    NASA Astrophysics Data System (ADS)

    Bradley, Ben K.

    Motivated by the growing space catalog and the demands for precise orbit determination with shorter latency for science and reconnaissance missions, this research improves the computational performance of orbit propagation through more efficient and precise numerical integration and frame transformation implementations. Propagation of satellite orbits is required for astrodynamics applications including mission design, orbit determination in support of operations and payload data analysis, and conjunction assessment. Each of these applications has somewhat different requirements in terms of accuracy, precision, latency, and computational load. This dissertation develops procedures to achieve various levels of accuracy while minimizing computational cost for diverse orbit determination applications. This is done by addressing two aspects of orbit determination: (1) numerical integration used for orbit propagation and (2) precise frame transformations necessary for force model evaluation and station coordinate rotations. This dissertation describes a recently developed method for numerical integration, dubbed Bandlimited Collocation Implicit Runge-Kutta (BLC-IRK), and compare its efficiency in propagating orbits to existing techniques commonly used in astrodynamics. The BLC-IRK scheme uses generalized Gaussian quadratures for bandlimited functions. It requires significantly fewer force function evaluations than explicit Runge-Kutta schemes and approaches the efficiency of the 8th-order Gauss-Jackson multistep method. Converting between the Geocentric Celestial Reference System (GCRS) and International Terrestrial Reference System (ITRS) is necessary for many applications in astrodynamics, such as orbit propagation, orbit determination, and analyzing geoscience data from satellite missions. This dissertation provides simplifications to the Celestial Intermediate Origin (CIO) transformation scheme and Earth orientation parameter (EOP) storage for use in positioning and orbit propagation, yielding savings in computation time and memory. Orbit propagation and position transformation simulations are analyzed to generate a complete set of recommendations for performing the ITRS/GCRS transformation for a wide range of needs, encompassing real-time on-board satellite operations and precise post-processing applications. In addition, a complete derivation of the ITRS/GCRS frame transformation time-derivative is detailed for use in velocity transformations between the GCRS and ITRS and is applied to orbit propagation in the rotating ITRS. EOP interpolation methods and ocean tide corrections are shown to impact the ITRS/GCRS transformation accuracy at the level of 5 cm and 20 cm on the surface of the Earth and at the Global Positioning System (GPS) altitude, respectively. The precession-nutation and EOP simplifications yield maximum propagation errors of approximately 2 cm and 1 m after 15 minutes and 6 hours in low-Earth orbit (LEO), respectively, while reducing computation time and memory usage. Finally, for orbit propagation in the ITRS, a simplified scheme is demonstrated that yields propagation errors under 5 cm after 15 minutes in LEO. This approach is beneficial for orbit determination based on GPS measurements. We conclude with a summary of recommendations on EOP usage and bias-precession-nutation implementations for achieving a wide range of transformation and propagation accuracies at several altitudes. This comprehensive set of recommendations allows satellite operators, astrodynamicists, and scientists to make informed decisions when choosing the best implementation for their application, balancing accuracy and computational complexity.

  6. Time to relapse after epilepsy surgery in children: AED withdrawal policies are a contributing factor.

    PubMed

    Boshuisen, Kim; Schmidt, Dieter; Uiterwaal, Cuno S P M; Arzimanoglou, Alexis; Braun, Kees P J; Study Group, TimeToStop

    2014-09-01

    It was recently suggested that early postoperative seizure relapse implicates a failure to define and resect the epileptogenic zone, that late recurrences reflect the persistence or re-emergence of epileptogenic pathology, and that early recurrences are associated with poor treatment response. Timing of antiepileptic drugs withdrawal policies, however, have never been taken into account when investigating time to relapse following epilepsy surgery. Of the European paediatric epilepsy surgery cohort from the "TimeToStop" study, all 95 children with postoperative seizure recurrence following antiepileptic drug (AED) withdrawal were selected. We investigated how time intervals from surgery to AED withdrawal, as well as other previously suggested determinants of (timing of) seizure recurrence, related to time to relapse and to relapse treatability. Uni- and multivariable linear and logistic regression models were used. Based on multivariable analysis, a shorter interval to AED reduction was the only independent predictor of a shorter time to relapse. Based on univariable analysis, incomplete resection of the epileptogenic zone related to a shorter time to recurrence. Timing of recurrence was not related to the chance of regaining seizure freedom after reinstallation of medical treatment. For children in whom AED reduction is initiated following epilepsy surgery, the time to relapse is largely influenced by the timing of AED withdrawal, rather than by disease or surgery-specific factors. We could not confirm a relationship between time to recurrence and treatment response. Timing of AED withdrawal should be taken into account when studying time to relapse following epilepsy surgery, as early withdrawal reveals more rapidly whether surgery had the intended curative effect, independently of the other factors involved.

  7. AN ANALYSIS OF SYSTEMS FOR FEEDING HOT MEALS TO THE ARMY IN THE FIELD DURING 1975-1990 TIME FRAME.

    DTIC Science & Technology

    An analysis was conducted of a large number of potential systems for feeding hot meals to the Army in the field during the 1975-1990 time frame...system of company level feeding . An analysis of alternative mixed systems (company level and higher) is also made indicating greater potential for food

  8. 75 FR 29897 - Approval and Promulgation of Implementation Plans; New York State Implementation Plan Revision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-28

    ... requirements of Section 12(d) of the National Technology Transfer and Advancement Act of 1995 (15 U.S.C. 272..., (212) 637-3381. SUPPLEMENTARY INFORMATION: Table of Contents I. What is the history and time frame for... Executive Order Reviews I. What is the history and time frame for State Implementation Plan (SIP...

  9. Stern Frame and Hawsepipe Construction Technology

    DTIC Science & Technology

    1978-01-01

    to the classificationsocieties regarding possible changes in the rules governing stern frame and hawsepipe designs were also considered. In the first...which were most representativeof the ships being constructedor contemplatedfor constructionin U.S. shipyards,and comparing them from the standpoint of...equipmentneeded in the manufacturing process. Time: Length of time needed to completeunits on a comparative 1.3 Summary of Results The data obtained

  10. Modeling of ablation threshold dependence on pulse duration for dielectrics with ultrashort pulsed laser

    NASA Astrophysics Data System (ADS)

    Sun, Mingying; Zhu, Jianqiang; Lin, Zunqi

    2017-01-01

    We present a numerical model of plasma formation in ultrafast laser ablation on the dielectrics surface. Ablation threshold dependence on pulse duration is predicted with the model and the numerical results for water agrees well with the experimental data for pulse duration from 140 fs to 10 ps. Influences of parameters and approximations of photo- and avalanche-ionization on the ablation threshold prediction are analyzed in detail for various pulse lengths. The calculated ablation threshold is strongly dependent on electron collision time for all the pulse durations. The complete photoionization model is preferred for pulses shorter than 1 ps rather than the multiphoton ionization approximations. The transition time of inverse bremsstrahlung absorption needs to be considered when pulses are shorter than 5 ps and it can also ensure the avalanche ionization (AI) coefficient consistent with that in multiple rate equations (MREs) for pulses shorter than 300 fs. The threshold electron density for AI is only crucial for longer pulses. It is reasonable to ignore the recombination loss for pulses shorter than 100 fs. In addition to thermal transport and hydrodynamics, neglecting the threshold density for AI and recombination could also contribute to the disagreements between the numerical and the experimental results for longer pulses.

  11. TreeMAC: Localized TDMA MAC protocol for real-time high-data-rate sensor networks

    USGS Publications Warehouse

    Song, W.-Z.; Huang, R.; Shirazi, B.; Husent, R.L.

    2009-01-01

    Earlier sensor network MAC protocols focus on energy conservation in low-duty cycle applications, while some recent applications involve real-time high-data-rate signals. This motivates us to design an innovative localized TDMA MAC protocol to achieve high throughput and low congestion in data collection sensor networks, besides energy conservation. TreeMAC divides a time cycle into frames and frame into slots. Parent determines children's frame assigmnent based on their relative bandwidth demand, and each node calculates its own slot assignment based on its hop-count to the sink. This innovative 2-dimensional frame-slot assignment algorithm has the following nice theory properties. Firstly, given any node, at any time slot, there is at most one active sender in its neighborhood (includ ing itself). Secondly, the packet scheduling with TreelMAC is bufferless, which therefore minimizes the probability of network congestion. Thirdly, the data throughput to gateway is at least 1/3 of the optimum assuming reliable links. Our experiments on a 24 node test bed demonstrate that TreeMAC protocol significantly improves network throughput and energy efficiency, by comparing to the TinyOS's default CSMA MAC protocol and a recent TDMA MAC protocol Funneling-MAC[8]. ?? 2009 IEEE.

  12. Reduction of capsule endoscopy reading times by unsupervised image mining.

    PubMed

    Iakovidis, D K; Tsevas, S; Polydorou, A

    2010-09-01

    The screening of the small intestine has become painless and easy with wireless capsule endoscopy (WCE) that is a revolutionary, relatively non-invasive imaging technique performed by a wireless swallowable endoscopic capsule transmitting thousands of video frames per examination. The average time required for the visual inspection of a full 8-h WCE video ranges from 45 to 120min, depending on the experience of the examiner. In this paper, we propose a novel approach to WCE reading time reduction by unsupervised mining of video frames. The proposed methodology is based on a data reduction algorithm which is applied according to a novel scheme for the extraction of representative video frames from a full length WCE video. It can be used either as a video summarization or as a video bookmarking tool, providing the comparative advantage of being general, unbounded by the finiteness of a training set. The number of frames extracted is controlled by a parameter that can be tuned automatically. Comprehensive experiments on real WCE videos indicate that a significant reduction in the reading times is feasible. In the case of the WCE videos used this reduction reached 85% without any loss of abnormalities.

  13. Exploring inter-frame correlation analysis and wavelet-domain modeling for real-time caption detection in streaming video

    NASA Astrophysics Data System (ADS)

    Li, Jia; Tian, Yonghong; Gao, Wen

    2008-01-01

    In recent years, the amount of streaming video has grown rapidly on the Web. Often, retrieving these streaming videos offers the challenge of indexing and analyzing the media in real time because the streams must be treated as effectively infinite in length, thus precluding offline processing. Generally speaking, captions are important semantic clues for video indexing and retrieval. However, existing caption detection methods often have difficulties to make real-time detection for streaming video, and few of them concern on the differentiation of captions from scene texts and scrolling texts. In general, these texts have different roles in streaming video retrieval. To overcome these difficulties, this paper proposes a novel approach which explores the inter-frame correlation analysis and wavelet-domain modeling for real-time caption detection in streaming video. In our approach, the inter-frame correlation information is used to distinguish caption texts from scene texts and scrolling texts. Moreover, wavelet-domain Generalized Gaussian Models (GGMs) are utilized to automatically remove non-text regions from each frame and only keep caption regions for further processing. Experiment results show that our approach is able to offer real-time caption detection with high recall and low false alarm rate, and also can effectively discern caption texts from the other texts even in low resolutions.

  14. Phase unwinding for dictionary compression with multiple channel transmission in magnetic resonance fingerprinting.

    PubMed

    Lattanzi, Riccardo; Zhang, Bei; Knoll, Florian; Assländer, Jakob; Cloos, Martijn A

    2018-06-01

    Magnetic Resonance Fingerprinting reconstructions can become computationally intractable with multiple transmit channels, if the B 1 + phases are included in the dictionary. We describe a general method that allows to omit the transmit phases. We show that this enables straightforward implementation of dictionary compression to further reduce the problem dimensionality. We merged the raw data of each RF source into a single k-space dataset, extracted the transceiver phases from the corresponding reconstructed images and used them to unwind the phase in each time frame. All phase-unwound time frames were combined in a single set before performing SVD-based compression. We conducted synthetic, phantom and in-vivo experiments to demonstrate the feasibility of SVD-based compression in the case of two-channel transmission. Unwinding the phases before SVD-based compression yielded artifact-free parameter maps. For fully sampled acquisitions, parameters were accurate with as few as 6 compressed time frames. SVD-based compression performed well in-vivo with highly under-sampled acquisitions using 16 compressed time frames, which reduced reconstruction time from 750 to 25min. Our method reduces the dimensions of the dictionary atoms and enables to implement any fingerprint compression strategy in the case of multiple transmit channels. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Initial Demonstration of 9-MHz Framing Camera Rates on the FAST UV Drive Laser Pulse Trains

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lumpkin, A. H.; Edstrom Jr., D.; Ruan, J.

    2016-10-09

    We report the configuration of a Hamamatsu C5680 streak camera as a framing camera to record transverse spatial information of green-component laser micropulses at 3- and 9-MHz rates for the first time. The latter is near the time scale of the ~7.5-MHz revolution frequency of the Integrable Optics Test Accelerator (IOTA) ring and its expected synchroton radiation source temporal structure. The 2-D images are recorded with a Gig-E readout CCD camera. We also report a first proof of principle with an OTR source using the linac streak camera in a semi-framing mode.

  16. Potential capabilities for compression of information of certain data processing systems

    NASA Technical Reports Server (NTRS)

    Khodarev, Y. K.; Yevdokimov, V. P.; Pokras, V. M.

    1974-01-01

    This article undertakes to study a generalized block diagram of a data collection and processing system of a spacecraft in which a number of sensors or outputs of scientific instruments are cyclically interrogated by a commutator, methods of writing the supplementary information in a frame on the example of a certain hypothetical telemetry system, and the influence of statistics of number of active channels in a frame on frame compression factor. The separation of the data compression factor of the collection and processing system of spacecraft into two parts used in this work allows determination of the compression factor of an active frame depending not only on the statistics of activity of channels in the telemetry frame, but also on the method of introduction of the additional address and time information to each frame.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Webb, Aaron P.; Carlson, Charles T.

    A multi-part mask has a pattern plate, which includes a planar portion that has the desired aperture pattern to be used during workpiece processing. The multi-part mask also has a mounting frame, which is used to hold the pattern plate. Prior to assembly, the pattern plate has an aligning portion, which has one or more holes through which reusable alignment pins are inserted. These alignment pins enter kinematic joints disposed on the mounting frame, which serve to precisely align the pattern plate to the mounting frame. After the pattern plate has been secured to the mounting frame, the aligning portionmore » can be detached from the pattern plate. The alignment pins can be reused at a later time. In some embodiments, the pattern plate can later be removed from the mounting frame, so that the mounting frame may be reused.« less

  18. What to do? The effects of discrepancies, incentives, and time on dynamic goal prioritization.

    PubMed

    Schmidt, Aaron M; DeShon, Richard P

    2007-07-01

    This study examined factors that influence the dynamic pursuit of multiple goals over time. As hypothesized, goal-performance discrepancies were significantly related to subsequent time allocation. Greater distance from a given goal resulted in greater time subsequently allocated to that goal. In addition, the incentives offered for goal attainment determined the relative influence of discrepancies for each goal. When the incentives for each goal were equivalent, progress toward each goal exhibited equal influence, with greater time allocated to whichever goal was furthest from completion at the time. However, with an incentive available for only 1 of the 2 goals, time allocation was largely determined by progress toward the rewarded goal. Likewise, when incentives for each task differed in their approach-avoidance framing, progress toward the avoidance-framed goal was a stronger predictor of subsequent allocation than was progress toward the approach-framed goal. Finally, the influence of goal-performance discrepancies differed as a function of the time remaining for goal pursuit. The implications for future work on dynamic goal prioritization and the provision of performance incentives are discussed.

  19. Use of full-frame sensors for height estimation of volcanic clouds

    NASA Astrophysics Data System (ADS)

    Zakšek, Klemen; Schilling, Klaus; Tzschichholz, Tristan; Hort, Matthias

    2017-04-01

    The quality of ash dispersion prediction is limited by the lack of high-quality information on eruption source parameters. One of the most important ones is the Volcanic Cloud Top Height (VCTH). Because of well-known uncertainties of currently operational methods, photogrammetric methods can be used to improve VCTH estimates. But even photogrammetric methods have difficulties because appropriate data are lacking. Here we propose an application of full-frame sensors that are available on the new generation of small satellites. A full-frame sensor makes a 2D image in a fraction of a second and it does not require a satellite to move, as a typical push-broom sensor does. In addition, full-frame sensors usually provide a better spatial resolution than most operational satellite instruments, resulting in a shorter minimal distance between satellites to produce a suitable parallax. From such images, it is possible to reconstruct a volcanic plume in 3D using methodology Structure from Motion (SfM) using the following workflow. 1) Convert images to grayscale and use local adaptive Wallis filter to enhance texture in images. 2) Use SfM software for sparse 3D reconstruction, which includes pose estimation of the cameras, features detection, and features matching. 3) Densify 3D reconstruction, create a mesh and optionally cover it with texture. 4) Use a 7-parameters similarity transformation (based on the satellite's orbit) to geolocate the results. The procedure has been tested with photos of 2009 Sarychev Peak eruption made by astronauts on the International Space Station (ISS), as a part of the NASA program Crew Earth observations. The estimated VCTH values are a bit larger than already published estimates. The presented work is just a pre-study of the forthcoming NetSat (planned launch at the end of 2017) and TOM mission (planned launch in 2019). These missions will provide VCTH based on simultaneous observations of clouds from different satellites - 4 (NetSat) and 3 (TOM) CubeSats will be flying in a pearl of strings or cartwheel formation. Both missions will fly on the height of 600 km with a distance of 100 km between two of them.

  20. Motivation and incentive preferences of community health officers in Ghana: an economic behavioral experiment approach.

    PubMed

    Shiratori, Sakiko; Agyekum, Enoch Oti; Shibanuma, Akira; Oduro, Abraham; Okawa, Sumiyo; Enuameh, Yeetey; Yasuoka, Junko; Kikuchi, Kimiyo; Gyapong, Margaret; Owusu-Agyei, Seth; Ansah, Evelyn; Hodgson, Abraham; Jimba, Masamine

    2016-08-22

    Health worker shortage in rural areas is one of the biggest problems of the health sector in Ghana and many developing countries. This may be due to fewer incentives and support systems available to attract and retain health workers at the rural level. This study explored the willingness of community health officers (CHOs) to accept and hold rural and community job postings in Ghana. A discrete choice experiment was used to estimate the motivation and incentive preferences of CHOs in Ghana. All CHOs working in three Health and Demographic Surveillance System sites in Ghana, 200 in total, were interviewed between December 2012 and January 2013. Respondents were asked to choose from choice sets of job preferences. Four mixed logit models were used for the estimation. The first model considered (a) only the main effect. The other models included interaction terms for (b) gender, (c) number of children under 5 in the household, and (d) years worked at the same community. Moreover, a choice probability simulation was performed. Mixed logit analyses of the data project a shorter time frame before study leave as the most important motivation for most CHOs (β 2.03; 95 % CI 1.69 to 2.36). This is also confirmed by the largest simulated choice probability (29.1 %). The interaction effect of the number of children was significant for education allowance for children (β 0.58; 95 % CI 0.24 to 0.93), salary increase (β 0.35; 95 % CI 0.03 to 0.67), and housing provision (β 0.16; 95 % CI -0.02 to 0.60). Male CHOs had a high affinity for early opportunity to go on study leave (β 0.78; 95 % CI -0.06 to 1.62). CHOs who had worked at the same place for a long time greatly valued salary increase (β 0.28; 95 % CI 0.09 to 0.47). To reduce health worker shortage in rural settings, policymakers could provide "needs-specific" motivational packages. They should include career development opportunities such as shorter period of work before study leave and financial policy in the form of salary increase to recruit and retain them.

  1. Characterization, adaptive traffic shaping, and multiplexing of real-time MPEG II video

    NASA Astrophysics Data System (ADS)

    Agrawal, Sanjay; Barry, Charles F.; Binnai, Vinay; Kazovsky, Leonid G.

    1997-01-01

    We obtain network traffic model for real-time MPEG-II encoded digital video by analyzing video stream samples from real-time encoders from NUKO Information Systems. MPEG-II sample streams include a resolution intensive movie, City of Joy, an action intensive movie, Aliens, a luminance intensive (black and white) movie, Road To Utopia, and a chrominance intensive (color) movie, Dick Tracy. From our analysis we obtain a heuristic model for the encoded video traffic which uses a 15-stage Markov process to model the I,B,P frame sequences within a group of pictures (GOP). A jointly-correlated Gaussian process is used to model the individual frame sizes. Scene change arrivals are modeled according to a gamma process. Simulations show that our MPEG-II traffic model generates, I,B,P frame sequences and frame sizes that closely match the sample MPEG-II stream traffic characteristics as they relate to latency and buffer occupancy in network queues. To achieve high multiplexing efficiency we propose a traffic shaping scheme which sets preferred 1-frame generation times among a group of encoders so as to minimize the overall variation in total offered traffic while still allowing the individual encoders to react to scene changes. Simulations show that our scheme results in multiplexing gains of up to 10% enabling us to multiplex twenty 6 Mbps MPEG-II video streams instead of 18 streams over an ATM/SONET OC3 link without latency or cell loss penalty. This scheme is due for a patent.

  2. Testing safety eyewear: how frame and lens design affect lens retention.

    PubMed

    McMahon, Janice M; Beckerman, Stephen

    2007-02-01

    The aim of this study was to determine the role that frame and lens design play in lens retention during high-impact testing of safety eyewear that advertises conformance to the performance-based ANSI Z87.1-2003 standard. A total of 75 Z87 safety eyeglass frames (3 each of 25 frame models) were used in this study, procured from 5 of the leading U.S. safety frame manufacturers. Frames were fitted by an independent laboratory with 2.0-mm plano polycarbonate lenses in compliance with ANSI Z87.1-2003. Finished spectacles were sent to a subsequent laboratory testing facility where each frame was subjected to both high-mass and oblique-incidence high-velocity impacts to determine frame characteristics that were most highly associated with testing failure. Among the frame and lens parameters that were considered in this analysis were the A and B dimensions, effective diameter, distance between lenses, bridge type, frame material, bevel type, and frame cost. Certain variables were controlled for by maintaining consistency among all spectacle pairs, e.g., lens prescription, center thickness, and edge thickness. Multiple logistic regression was used to control potential confounding variables and to develop the best combination of them for predictive value. Of 25 separate frame models assessed, 10 passed both high-mass and high-velocity impact testing, i.e., none of the 3 frame/lens samples failed. Of the models that failed, 13 failures were caused by high-velocity testing, 1 by high-mass testing, and 1 failed both high-mass and high-velocity testing. None of the 15 spectacles with the SprinGuardtrade mark (Hilco, Plainville, Massachusetts) bevel design failed, although these were proprietary to 1 manufacturer and included only 5 frame models. Two spectacle designs (6 individual frames) incorporated an inverted bevel design of which 3 of the frames failed impact testing. Controlling for drop ball velocity among the 54 remaining standard "V" bevel spectacle pairs, the odds of failure were about 8 to 9 times higher for metal frames than Zylonite frames (odds ratio [OR], 8.5; 95% confidence interval [CI], 1.4 to 52.3; P = 0.02), and the odds of failure were about 4 times higher for lens effective diameters of less than 50 mm than for lens effective diameters more than 50 mm (OR, 4.1; 95% CI, 1.2 to 14.8; P = 0.03). Among our sample of safety spectacles, failure from high-mass impact resistance testing rarely occurred. No spectacles with the SprinGuard bevel design failed in our analysis, but this was limited to a small sample size from a single manufacturer. Among our sample of 54 spectacle pairs with a v-bevel design, metal frame material and an effective diameter of less than 50 mm were the strongest predictors of failure relative to high-velocity impact testing with a 45 degrees temporal angle projectile.

  3. Video segmentation using keywords

    NASA Astrophysics Data System (ADS)

    Ton-That, Vinh; Vong, Chi-Tai; Nguyen-Dao, Xuan-Truong; Tran, Minh-Triet

    2018-04-01

    At DAVIS-2016 Challenge, many state-of-art video segmentation methods achieve potential results, but they still much depend on annotated frames to distinguish between background and foreground. It takes a lot of time and efforts to create these frames exactly. In this paper, we introduce a method to segment objects from video based on keywords given by user. First, we use a real-time object detection system - YOLOv2 to identify regions containing objects that have labels match with the given keywords in the first frame. Then, for each region identified from the previous step, we use Pyramid Scene Parsing Network to assign each pixel as foreground or background. These frames can be used as input frames for Object Flow algorithm to perform segmentation on entire video. We conduct experiments on a subset of DAVIS-2016 dataset in half the size of its original size, which shows that our method can handle many popular classes in PASCAL VOC 2012 dataset with acceptable accuracy, about 75.03%. We suggest widely testing by combining other methods to improve this result in the future.

  4. Elasticity-based determination of isovolumetric phases in the human heart

    PubMed Central

    2010-01-01

    Background/Motivation To directly determine isovolumetric cardiac time intervals by magnetic resonance elastography (MRE) using the magnitude of the complex signal for deducing morphological information combined with the phase of the complex signal for tension-relaxation measurements. Methods Thirty-five healthy volunteers and 11 patients with relaxation abnormalities were subjected to transthoracic wave stimulation using vibrations of approximately 25 Hz. A k-space-segmented, ECG-gated gradient-recalled echo steady-state sequence with a 500-Hz bipolar motion-encoding gradient was used for acquiring a series of 360 complex images of a short-axis view of the heart at a frame rate of less than 5.2 ms. Magnitude images were employed for measuring the cross-sectional area of the left ventricle, while phase images were used for analyzing the amplitudes of the externally induced waves. The delay between the decrease in amplitude and onset of ventricular contraction was determined in all subjects and assigned to the time of isovolumetric tension. Conversely, the delay between the increase in wave amplitude and ventricular dilatation was used for measuring the time of isovolumetric elasticity relaxation. Results Wave amplitudes decreased during systole and increased during diastole. The variation in wave amplitude occurred ahead of morphological changes. In healthy volunteers the time of isovolumetric elasticity relaxation was 75 ± 31 ms, which is significantly shorter than the time of isovolumetric tension of 136 ± 36 ms (P < 0.01). In patients with relaxation abnormalities (mild diastolic dysfunction, n = 11) isovolumetric elasticity relaxation was significantly prolonged, with 133 ± 57 ms (P < 0.01), whereas isovolumetric tension time was in the range of healthy controls (161 ± 45 ms; P = 0.053). Conclusion The complex MRE signal conveys complementary information on cardiac morphology and elasticity, which can be combined for directly measuring isovolumetric tension and elasticity relaxation in the human heart. PMID:20979648

  5. Elasticity-based determination of isovolumetric phases in the human heart.

    PubMed

    Elgeti, Thomas; Beling, Mark; Hamm, Bernd; Braun, Jürgen; Sack, Ingolf

    2010-10-27

    BACKGROUND/MOTIVATION: To directly determine isovolumetric cardiac time intervals by magnetic resonance elastography (MRE) using the magnitude of the complex signal for deducing morphological information combined with the phase of the complex signal for tension-relaxation measurements. Thirty-five healthy volunteers and 11 patients with relaxation abnormalities were subjected to transthoracic wave stimulation using vibrations of approximately 25 Hz. A k-space-segmented, ECG-gated gradient-recalled echo steady-state sequence with a 500-Hz bipolar motion-encoding gradient was used for acquiring a series of 360 complex images of a short-axis view of the heart at a frame rate of less than 5.2 ms. Magnitude images were employed for measuring the cross-sectional area of the left ventricle, while phase images were used for analyzing the amplitudes of the externally induced waves. The delay between the decrease in amplitude and onset of ventricular contraction was determined in all subjects and assigned to the time of isovolumetric tension. Conversely, the delay between the increase in wave amplitude and ventricular dilatation was used for measuring the time of isovolumetric elasticity relaxation. Wave amplitudes decreased during systole and increased during diastole. The variation in wave amplitude occurred ahead of morphological changes. In healthy volunteers the time of isovolumetric elasticity relaxation was 75 ± 31 ms, which is significantly shorter than the time of isovolumetric tension of 136 ± 36 ms (P < 0.01). In patients with relaxation abnormalities (mild diastolic dysfunction, n = 11) isovolumetric elasticity relaxation was significantly prolonged, with 133 ± 57 ms (P < 0.01), whereas isovolumetric tension time was in the range of healthy controls (161 ± 45 ms; P = 0.053). The complex MRE signal conveys complementary information on cardiac morphology and elasticity, which can be combined for directly measuring isovolumetric tension and elasticity relaxation in the human heart.

  6. Speech coding, reconstruction and recognition using acoustics and electromagnetic waves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holzrichter, J.F.; Ng, L.C.

    The use of EM radiation in conjunction with simultaneously recorded acoustic speech information enables a complete mathematical coding of acoustic speech. The methods include the forming of a feature vector for each pitch period of voiced speech and the forming of feature vectors for each time frame of unvoiced, as well as for combined voiced and unvoiced speech. The methods include how to deconvolve the speech excitation function from the acoustic speech output to describe the transfer function each time frame. The formation of feature vectors defining all acoustic speech units over well defined time frames can be used formore » purposes of speech coding, speech compression, speaker identification, language-of-speech identification, speech recognition, speech synthesis, speech translation, speech telephony, and speech teaching. 35 figs.« less

  7. Denosumab and Bone Metastasis–Free Survival in Men With Nonmetastatic Castration-Resistant Prostate Cancer: Exploratory Analyses by Baseline Prostate-Specific Antigen Doubling Time

    PubMed Central

    Smith, Matthew R.; Saad, Fred; Oudard, Stephane; Shore, Neal; Fizazi, Karim; Sieber, Paul; Tombal, Bertrand; Damiao, Ronaldo; Marx, Gavin; Miller, Kurt; Van Veldhuizen, Peter; Morote, Juan; Ye, Zhishen; Dansey, Roger; Goessl, Carsten

    2013-01-01

    Purpose Denosumab, an anti–RANK ligand monoclonal antibody, significantly increases bone metastasis–free survival (BMFS; hazard ratio [HR], 0.85; P = .028) and delays time to first bone metastasis in men with nonmetastatic castration-resistant prostate cancer (CRPC) and baseline prostate-specific antigen (PSA) ≥ 8.0 ng/mL and/or PSA doubling time (PSADT) ≤ 10.0 months. To identify men at greatest risk for bone metastasis or death, we evaluated relationships between PSA and PSADT with BMFS in the placebo group and the efficacy and safety of denosumab in men with PSADT ≤ 10, ≤ 6, and ≤ 4 months. Patients and Methods A total of 1,432 men with nonmetastatic CRPC were randomly assigned 1:1 to monthly subcutaneous denosumab 120 mg or placebo. Enrollment began February 2006; primary analysis cutoff was July 2010, when approximately 660 men were anticipated to have developed bone metastases or died. Results In the placebo group, shorter BMFS was observed as PSADT decreased below 8 months. In analyses by shorter baseline PSADT, denosumab consistently increased BMFS by a median of 6.0, 7.2, and 7.5 months among men with PSADT ≤ 10 (HR, 0.84; P = .042), ≤ 6 (HR, 0.77; P = .006), and ≤ 4 months (HR, 0.71; P = .004), respectively. Denosumab also consistently increased time to bone metastasis by PSADT subset. No difference in survival was observed between treatment groups for the overall study population or PSADT subsets. Conclusion Patients with shorter PSADT are at greater risk for bone metastasis or death. Denosumab consistently improves BMFS in men with shorter PSADT and seems to have the greatest treatment effects in men at high risk for progression. PMID:24043751

  8. Denosumab and bone metastasis-free survival in men with nonmetastatic castration-resistant prostate cancer: exploratory analyses by baseline prostate-specific antigen doubling time.

    PubMed

    Smith, Matthew R; Saad, Fred; Oudard, Stephane; Shore, Neal; Fizazi, Karim; Sieber, Paul; Tombal, Bertrand; Damiao, Ronaldo; Marx, Gavin; Miller, Kurt; Van Veldhuizen, Peter; Morote, Juan; Ye, Zhishen; Dansey, Roger; Goessl, Carsten

    2013-10-20

    Denosumab, an anti-RANK ligand monoclonal antibody, significantly increases bone metastasis-free survival (BMFS; hazard ratio [HR], 0.85; P = .028) and delays time to first bone metastasis in men with nonmetastatic castration-resistant prostate cancer (CRPC) and baseline prostate-specific antigen (PSA) ≥ 8.0 ng/mL and/or PSA doubling time (PSADT) ≤ 10.0 months. To identify men at greatest risk for bone metastasis or death, we evaluated relationships between PSA and PSADT with BMFS in the placebo group and the efficacy and safety of denosumab in men with PSADT ≤ 10, ≤ 6, and ≤ 4 months. A total of 1,432 men with nonmetastatic CRPC were randomly assigned 1:1 to monthly subcutaneous denosumab 120 mg or placebo. Enrollment began February 2006; primary analysis cutoff was July 2010, when approximately 660 men were anticipated to have developed bone metastases or died. In the placebo group, shorter BMFS was observed as PSADT decreased below 8 months. In analyses by shorter baseline PSADT, denosumab consistently increased BMFS by a median of 6.0, 7.2, and 7.5 months among men with PSADT ≤ 10 (HR, 0.84; P = .042), ≤ 6 (HR, 0.77; P = .006), and ≤ 4 months (HR, 0.71; P = .004), respectively. Denosumab also consistently increased time to bone metastasis by PSADT subset. No difference in survival was observed between treatment groups for the overall study population or PSADT subsets. Patients with shorter PSADT are at greater risk for bone metastasis or death. Denosumab consistently improves BMFS in men with shorter PSADT and seems to have the greatest treatment effects in men at high risk for progression.

  9. Clinical and molecular predictors of disease severity and survival in chronic lymphocytic leukemia.

    PubMed

    Weinberg, J Brice; Volkheimer, Alicia D; Chen, Youwei; Beasley, Bethany E; Jiang, Ning; Lanasa, Mark C; Friedman, Daphne; Vaccaro, Gina; Rehder, Catherine W; Decastro, Carlos M; Rizzieri, David A; Diehl, Louis F; Gockerman, Jon P; Moore, Joseph O; Goodman, Barbara K; Levesque, Marc C

    2007-12-01

    Several parameters may predict disease severity and overall survival in chronic lymphocytic leukemia (CLL). The purpose of our study of 190 CLL patients was to compare immunoglobulin heavy chain variable region (IgV(H)) mutation status, cytogenetic abnormalities, and leukemia cell CD38 and Zap-70 to older, traditional parameters. We also wanted to construct a simple, inexpensive prognosis score that would significantly predict TTT and survival in patients at the time of diagnosis and help practicing clinicians. In univariate analyses, patients with higher clinical stage, higher leukocyte count at diagnosis, shorter leukocyte doubling time, elevated serum lactate dehydrogenase (LDH), unmutated immunoglobulin heavy chain variable region (IgV(H)) genes, and higher CD38 had a shorter overall survival and time-to-treatment (TTT). CLL cell Zap-70 expression was higher in patients with unmutated IgV(H), and those with higher Zap-70 tended to have shorter survival. IgV(H)4-34 or IgV(H)1-69 was the most common IgV(H) genes used (16 and 12%, respectively). Of those with IgV(H)1-69, 86% had unmutated IgV(H) and had a significantly shorter TTT. A cytogenetic abnormality was noted in 71% of the patients tested. Patients with 11q22 del and 17p13 del or complex abnormalities were significantly more likely to have unmutated IgV(H). We found that a prognostic score constructed using modified Rai stage, cellular CD38, and serum LDH (parameters easily obtained clinically) significantly predicted TTT and survival in patients at the time of diagnosis and performed as well or better than models using the newer markers.

  10. The Role of Prophylactic Endoscopic Sphincterotomy for Prevention of Postoperative Bile Leak in Hydatid Liver Disease: A Randomized Controlled Study.

    PubMed

    El-Gendi, Ahmed M; El-Shafei, Mohamed; Bedewy, Essam

    2018-03-12

    Bile leak is the main cause of morbidity and mortality after surgery for hydatid liver cysts. Aim was to assess the role of prophylactic endoscopic sphincterotomy (ES) in reducing postoperative bile leak in patients undergoing partial cystectomy. Fifty-four patients with hepatic hydatid cyst met inclusion criteria, 27 were excluded or declined to participate. Twenty-six women and 28 men (mean age 44.6 ± 10.1, range: 22-61 years) were randomly assigned to either group I with ES (n = 27) or group II without ES (n = 27). Demographics and clinical, laboratory, and radiological characteristics of cysts were not statistically different between two groups. Group I had a significant decrease in bile leak rate compared with group II (11.1% versus 40.7%, P = .013), with significantly shorter duration of hospital stay (P < .0001). Biliary fistula in group I had significantly lower daily output (100 mL/day versus 350 mL/day) with gradual reduction till stoppage of leak in 3-4 days without intervention. Biliary fistula in group II had a significantly higher need for biliary intervention through postoperative endoscopic retrograde cholangiopancreatography with ES compared with biliary fistula in group I ( FE P = .002), with significantly longer mean time of fistula closure (P = .011) and longer time to drain removal (P < .0001). Nonbiliary complications were comparable between two groups. Prophylactic ES provides significant reduction in postoperative bile leak rate with shorter hospital stay after partial cystectomy of hydatid cyst. Biliary fistula in patients with ES has significantly lower daily output with shorter time of drain removal and shorter time to closure than patients without ES.

  11. Estimating the time evolution of NMR systems via a quantum-speed-limit-like expression

    NASA Astrophysics Data System (ADS)

    Villamizar, D. V.; Duzzioni, E. I.; Leal, A. C. S.; Auccaise, R.

    2018-05-01

    Finding the solutions of the equations that describe the dynamics of a given physical system is crucial in order to obtain important information about its evolution. However, by using estimation theory, it is possible to obtain, under certain limitations, some information on its dynamics. The quantum-speed-limit (QSL) theory was originally used to estimate the shortest time in which a Hamiltonian drives an initial state to a final one for a given fidelity. Using the QSL theory in a slightly different way, we are able to estimate the running time of a given quantum process. For that purpose, we impose the saturation of the Anandan-Aharonov bound in a rotating frame of reference where the state of the system travels slower than in the original frame (laboratory frame). Through this procedure it is possible to estimate the actual evolution time in the laboratory frame of reference with good accuracy when compared to previous methods. Our method is tested successfully to predict the time spent in the evolution of nuclear spins 1/2 and 3/2 in NMR systems. We find that the estimated time according to our method is better than previous approaches by up to four orders of magnitude. One disadvantage of our method is that we need to solve a number of transcendental equations, which increases with the system dimension and parameter discretization used to solve such equations numerically.

  12. Mountain bicycle frame testing as an example of practical implementation of hybrid simulation using RTFEM

    NASA Astrophysics Data System (ADS)

    Mucha, Waldemar; Kuś, Wacław

    2018-01-01

    The paper presents a practical implementation of hybrid simulation using Real Time Finite Element Method (RTFEM). Hybrid simulation is a technique for investigating dynamic material and structural properties of mechanical systems by performing numerical analysis and experiment at the same time. It applies to mechanical systems with elements too difficult or impossible to model numerically. These elements are tested experimentally, while the rest of the system is simulated numerically. Data between the experiment and numerical simulation are exchanged in real time. Authors use Finite Element Method to perform the numerical simulation. The following paper presents the general algorithm for hybrid simulation using RTFEM and possible improvements of the algorithm for computation time reduction developed by the authors. The paper focuses on practical implementation of presented methods, which involves testing of a mountain bicycle frame, where the shock absorber is tested experimentally while the rest of the frame is simulated numerically.

  13. The time-dependence of exchange-induced relaxation during modulated radio frequency pulses.

    PubMed

    Sorce, Dennis J; Michaeli, Shalom; Garwood, Michael

    2006-03-01

    The problem of the relaxation of identical spins 1/2 induced by chemical exchange between spins with different chemical shifts in the presence of time-dependent RF irradiation (in the first rotating frame) is considered for the fast exchange regime. The solution for the time evolution under the chemical exchange Hamiltonian in the tilted doubly rotating frame (TDRF) is presented. Detailed derivation is specified to the case of a two-site chemical exchange system with complete randomization between jumps of the exchanging spins. The derived theory can be applied to describe the modulation of the chemical exchange relaxation rate constants when using a train of adiabatic pulses, such as the hyperbolic secant pulse. Theory presented is valid for quantification of the exchange-induced time-dependent rotating frame longitudinal T1rho,ex and transverse T2rho,ex relaxations in the fast chemical exchange regime.

  14. An application of a relational database system for high-throughput prediction of elemental compositions from accurate mass values.

    PubMed

    Sakurai, Nozomu; Ara, Takeshi; Kanaya, Shigehiko; Nakamura, Yukiko; Iijima, Yoko; Enomoto, Mitsuo; Motegi, Takeshi; Aoki, Koh; Suzuki, Hideyuki; Shibata, Daisuke

    2013-01-15

    High-accuracy mass values detected by high-resolution mass spectrometry analysis enable prediction of elemental compositions, and thus are used for metabolite annotations in metabolomic studies. Here, we report an application of a relational database to significantly improve the rate of elemental composition predictions. By searching a database of pre-calculated elemental compositions with fixed kinds and numbers of atoms, the approach eliminates redundant evaluations of the same formula that occur in repeated calculations with other tools. When our approach is compared with HR2, which is one of the fastest tools available, our database search times were at least 109 times shorter than those of HR2. When a solid-state drive (SSD) was applied, the search time was 488 times shorter at 5 ppm mass tolerance and 1833 times at 0.1 ppm. Even if the search by HR2 was performed with 8 threads in a high-spec Windows 7 PC, the database search times were at least 26 and 115 times shorter without and with the SSD. These improvements were enhanced in a low spec Windows XP PC. We constructed a web service 'MFSearcher' to query the database in a RESTful manner. Available for free at http://webs2.kazusa.or.jp/mfsearcher. The web service is implemented in Java, MySQL, Apache and Tomcat, with all major browsers supported. sakurai@kazusa.or.jp Supplementary data are available at Bioinformatics online.

  15. Long-Term Variations of the EOP and ICRF2

    NASA Technical Reports Server (NTRS)

    Zharov, Vladimir; Sazhin, Mikhail; Sementsov, Valerian; Sazhina, Olga

    2010-01-01

    We analyzed the time series of the coordinates of the ICRF radio sources. We show that part of the radio sources, including the defining sources, shows a significant apparent motion. The stability of the celestial reference frame is provided by a no-net-rotation condition applied to the defining sources. In our case this condition leads to a rotation of the frame axes with time. We calculated the effect of this rotation on the Earth orientation parameters (EOP). In order to improve the stability of the celestial reference frame we suggest a new method for the selection of the defining sources. The method consists of two criteria: the first one we call cosmological and the second one kinematical. It is shown that a subset of the ICRF sources selected according to cosmological criteria provides the most stable reference frame for the next decade.

  16. Flexible nuclear medicine camera and method of using

    DOEpatents

    Dilmanian, F. Avraham; Packer, Samuel; Slatkin, Daniel N.

    1996-12-10

    A nuclear medicine camera 10 and method of use photographically record radioactive decay particles emitted from a source, for example a small, previously undetectable breast cancer, inside a patient. The camera 10 includes a flexible frame 20 containing a window 22, a photographic film 24, and a scintillation screen 26, with or without a gamma-ray collimator 34. The frame 20 flexes for following the contour of the examination site on the patient, with the window 22 being disposed in substantially abutting contact with the skin of the patient for reducing the distance between the film 24 and the radiation source inside the patient. The frame 20 is removably affixed to the patient at the examination site for allowing the patient mobility to wear the frame 20 for a predetermined exposure time period. The exposure time may be several days for obtaining early qualitative detection of small malignant neoplasms.

  17. Multithreaded hybrid feature tracking for markerless augmented reality.

    PubMed

    Lee, Taehee; Höllerer, Tobias

    2009-01-01

    We describe a novel markerless camera tracking approach and user interaction methodology for augmented reality (AR) on unprepared tabletop environments. We propose a real-time system architecture that combines two types of feature tracking. Distinctive image features of the scene are detected and tracked frame-to-frame by computing optical flow. In order to achieve real-time performance, multiple operations are processed in a synchronized multi-threaded manner: capturing a video frame, tracking features using optical flow, detecting distinctive invariant features, and rendering an output frame. We also introduce user interaction methodology for establishing a global coordinate system and for placing virtual objects in the AR environment by tracking a user's outstretched hand and estimating a camera pose relative to it. We evaluate the speed and accuracy of our hybrid feature tracking approach, and demonstrate a proof-of-concept application for enabling AR in unprepared tabletop environments, using bare hands for interaction.

  18. Improved frame-based estimation of head motion in PET brain imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mukherjee, J. M., E-mail: joyeeta.mitra@umassmed.edu; Lindsay, C.; King, M. A.

    Purpose: Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. Methods: The list mode data for PET acquisition ismore » uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. Results: The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. Conclusions: The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type.« less

  19. Improved frame-based estimation of head motion in PET brain imaging

    PubMed Central

    Mukherjee, J. M.; Lindsay, C.; Mukherjee, A.; Olivier, P.; Shao, L.; King, M. A.; Licho, R.

    2016-01-01

    Purpose: Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. Methods: The list mode data for PET acquisition is uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. Results: The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. Conclusions: The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type. PMID:27147355

  20. Quantitative contrast-enhanced ultrasonography for the differential diagnosis of endometrial hyperplasia and endometrial neoplasms

    PubMed Central

    Liu, Ying; Xu, Yi; Cheng, Wen; Liu, Xinghan

    2016-01-01

    The present study aimed to investigate the feasibility of applying contrast-enhanced ultrasonography (CEUS) imaging technology for distinguishing between benign and malignant endometrial lesions, and to screen markers that could be correlated with the pathological results. In this study, endometrial diseases were diagnosed by biopsy under hysteroscopy and CEUS examinations. The intensity and time parameters of the time-intensity curve (TIC) were analyzed. The mean arrival time (AT), time-to-peak (TTP), rise time (RT), washout half-time and clearance half-time of malignant lesions were shorter than those of benign lesions (P<0.05), whereas the average peak intensity (PI) and enhancement intensity (EI) of malignant lesions were higher than those of benign lesions (P<0.05). The receiver operating characteristic curve showed the following cut-off values: PI, 29.2 dB; EI, 21.35 dB; AT, 12.75 sec; TTP, 26.75 sec; RT, 13.2 sec; clearance half-time, 89.3 sec; and washout half-time, 75.45 sec. The lesions with PI, an EI higher than that of the cut-off and lesions with an AT, TTP, RT, half clearing time and washout half-time shorter than the cut-off were considered malignant. The TTP, RT and half clearing time were negatively correlated with microvessel density (MVD), i.e., MVD was higher when the TTP, RT and half clearing time were shorter. Overall, changes in the enhancement and clearing of lesions could be quantitatively analyzed by CEUS TIC and further discriminate benign from malignant lesions. In the present study, CEUS appeared to indirectly reflect blood vessel changes inside the lesions and provided a pre-operative non-invasive fast imaging method for the diagnosis of endometrial disease. PMID:27895728

  1. Structural Characterization and Evolutionary Relationship of High-Molecular-Weight Glutenin Subunit Genes in Roegneria nakaii and Roegneria alashanica.

    PubMed

    Zhang, Lujun; Li, Zhixin; Fan, Renchun; Wei, Bo; Zhang, Xiangqi

    2016-07-19

    The Roegneria of Triticeae is a large genus including about 130 allopolyploid species. Little is known about its high-molecular-weight glutenin subunits (HMW-GSs). Here, we reported six novel HMW-GS genes from R. nakaii and R. alashanica. Sequencing indicated that Rny1, Rny3, and Ray1 possessed intact open reading frames (ORFs), whereas Rny2, Rny4, and Ray2 harbored in-frame stop codons. All of the six genes possessed a similar primary structure to known HMW-GS, while showing some unique characteristics. Their coding regions were significantly shorter than Glu-1 genes in wheat. The amino acid sequences revealed that all of the six genes were intermediate towards the y-type. The phylogenetic analysis showed that the HMW-GSs from species with St, StY, or StH genome(s) clustered in an independent clade, varying from the typical x- and y-type clusters. Thus, the Glu-1 locus in R. nakaii and R. alashanica is a very primitive glutenin locus across evolution. The six genes were phylogenetically split into two groups clustered to different clades, respectively, each of the two clades included the HMW-GSs from species with St (diploid and tetraploid species), StY, and StH genomes. Hence, it is concluded that the six Roegneria HMW-GS genes are from two St genomes undergoing slight differentiation.

  2. Implications of an Absolute Simultaneity Theory for Cosmology and Universe Acceleration

    PubMed Central

    Kipreos, Edward T.

    2014-01-01

    An alternate Lorentz transformation, Absolute Lorentz Transformation (ALT), has similar kinematics to special relativity yet maintains absolute simultaneity in the context of a preferred reference frame. In this study, it is shown that ALT is compatible with current experiments to test Lorentz invariance only if the proposed preferred reference frame is locally equivalent to the Earth-centered non-rotating inertial reference frame, with the inference that in an ALT framework, preferred reference frames are associated with centers of gravitational mass. Applying this theoretical framework to cosmological data produces a scenario of universal time contraction in the past. In this scenario, past time contraction would be associated with increased levels of blueshifted light emissions from cosmological objects when viewed from our current perspective. The observation that distant Type Ia supernovae are dimmer than predicted by linear Hubble expansion currently provides the most direct evidence for an accelerating universe. Adjusting for the effects of time contraction on a redshift–distance modulus diagram produces a linear distribution of supernovae over the full redshift spectrum that is consistent with a non-accelerating universe. PMID:25536116

  3. Implications of an absolute simultaneity theory for cosmology and universe acceleration.

    PubMed

    Kipreos, Edward T

    2014-01-01

    An alternate Lorentz transformation, Absolute Lorentz Transformation (ALT), has similar kinematics to special relativity yet maintains absolute simultaneity in the context of a preferred reference frame. In this study, it is shown that ALT is compatible with current experiments to test Lorentz invariance only if the proposed preferred reference frame is locally equivalent to the Earth-centered non-rotating inertial reference frame, with the inference that in an ALT framework, preferred reference frames are associated with centers of gravitational mass. Applying this theoretical framework to cosmological data produces a scenario of universal time contraction in the past. In this scenario, past time contraction would be associated with increased levels of blueshifted light emissions from cosmological objects when viewed from our current perspective. The observation that distant Type Ia supernovae are dimmer than predicted by linear Hubble expansion currently provides the most direct evidence for an accelerating universe. Adjusting for the effects of time contraction on a redshift-distance modulus diagram produces a linear distribution of supernovae over the full redshift spectrum that is consistent with a non-accelerating universe.

  4. Saturn's E Ring in Ultraviolet Light

    NASA Technical Reports Server (NTRS)

    2002-01-01

    Visible from Earth only at times of ring plane crossing, Saturn's tenuous E Ring was discovered during the 1966 crossings and imaged again in 1980. From these observations, its color is known to be distinctively blue. The E Ring was captured in ultraviolet light for the first time in this image taken with HST's Wide Field and Planetary Camera on 9 August 1995. Five individual images taken with a broadband 3000 A filter were combined, amounting to a total exposure time of 2200 sec. Shorter exposure images were also obtained with blue, red and infrared filters in order to characterize the ring's color. The peak brightness of the E Ring occurs at 3.9 Saturn radii (235,000 km), coinciding with the orbit of Enceladus. In the HST images it can be traced out to a maximum distance of approximately 8 Rs (480,000 km). The vertical thickness of the ring, on the other hand, is smallest at Enceladus' orbit, with the ring puffing up noticeably at larger distances to 15,000 km or more thick. Also visible in this image, between the E Ring and the overexposed outermost part of the main rings near the lower edge of the frame, is the tenuous, thin, 6000 km-wide G Ring at 2.8 Rs (170,000 km). This is among the first earth-based observations of the G Ring, which was discovered by the Pioneer 11 spacecraft in 1979. Noticeably thinner than the E Ring and more neutral in color, the G Ring is thought to be composed of larger, macroscopic particles, and to pose a significant hazard to spacecraft. The faint diagonal band in the lower right part of the image is due to diffracted light from the heavily-overexposed planet. Credit: Phil Nicholson (Cornell University), Mark Showalter (NASA-Ames/Stanford) and NASA

  5. Validating Satellite-Derived Land Surface Temperature with in Situ Measurements: A Public Health Perspective

    PubMed Central

    Brines, Shannon J.; Brown, Daniel G.; Dvonch, J. Timothy; Gronlund, Carina J.; Zhang, Kai; Oswald, Evan M.; O’Neill, Marie S.

    2013-01-01

    Background: Land surface temperature (LST) and percent surface imperviousness (SI), both derived from satellite imagery, have been used to characterize the urban heat island effect, a phenomenon in which urban areas are warmer than non-urban areas. Objectives: We aimed to assess the correlations between LSTs and SI images with actual temperature readings from a ground-based network of outdoor monitors. Methods: We evaluated the relationships among a) LST calculated from a 2009 summertime satellite image of the Detroit metropolitan region, Michigan; b) SI from the 2006 National Land Cover Data Set; and c) ground-based temperature measurements monitored during the same time period at 19 residences throughout the Detroit metropolitan region. Associations between these ground-based temperatures and the average LSTs and SI at different radii around the point of the ground-based temperature measurement were evaluated at different time intervals. Spearman correlation coefficients and corresponding p-values were calculated. Results: Satellite-derived LST and SI values were significantly correlated with 24-hr average and August monthly average ground temperatures at all but two of the radii examined (100 m for LST and 0 m for SI). Correlations were also significant for temperatures measured between 0400 and 0500 hours for SI, except at 0 m, but not LST. Statistically significant correlations ranging from 0.49 to 0.91 were observed between LST and SI. Conclusions: Both SI and LST could be used to better understand spatial variation in heat exposures over longer time frames but are less useful for estimating shorter-term, actual temperature exposures, which can be useful for public health preparedness during extreme heat events. PMID:23777856

  6. Sex differences in visual attention to sexually explicit videos: a preliminary study.

    PubMed

    Tsujimura, Akira; Miyagawa, Yasushi; Takada, Shingo; Matsuoka, Yasuhiro; Takao, Tetsuya; Hirai, Toshiaki; Matsushita, Masateru; Nonomura, Norio; Okuyama, Akihiko

    2009-04-01

    Although men appear to be more interested in sexual stimuli than women, this difference is not completely understood. Eye-tracking technology has been used to investigate visual attention to still sexual images; however, it has not been applied to moving sexual images. To investigate whether sex difference exists in visual attention to sexual videos. Eleven male and 11 female healthy volunteers were studied by our new methodology. The subjects viewed two sexual videos (one depicting sexual intercourse and one not) in which several regions were designated for eye-gaze analysis in each frame. Visual attention was measured across each designated region according to gaze duration. Sex differences, the region attracting the most attention, and visually favored sex were evaluated. In the nonintercourse clip, gaze time for the face and body of the actress was significantly shorter among women than among men. Gaze time for the face and body of the actor and nonhuman regions was significantly longer for women than men. The region attracting the most attention was the face of the actress for both men and women. Men viewed the opposite sex for a significantly longer period than did women, and women viewed their own sex for a significantly longer period than did men. However, gaze times for the clip showing intercourse were not significantly different between sexes. A sex difference existed in visual attention to a sexual video without heterosexual intercourse; men viewed the opposite sex for longer periods than did women, and women viewed the same sex for longer periods than did men. There was no statistically significant sex difference in viewing patterns in a sexual video showing heterosexual intercourse, and we speculate that men and women may have similar visual attention patterns if the sexual stimuli are sufficiently explicit.

  7. In search of optimal compression therapy for venous leg ulcers: a meta-analysis of studies comparing diverse [corrected] bandages with specifically designed stockings.

    PubMed

    Amsler, Felix; Willenberg, Torsten; Blättler, Werner

    2009-09-01

    In search of an optimal compression therapy for venous leg ulcers, a systematic review and meta-analysis was performed of randomized controlled trials (RCT) comparing compression systems based on stockings (MCS) with divers bandages. RCT were retrieved from six sources and reviewed independently. The primary endpoint, completion of healing within a defined time frame, and the secondary endpoints, time to healing, and pain were entered into a meta-analysis using the tools of the Cochrane Collaboration. Additional subjective endpoints were summarized. Eight RCT (published 1985-2008) fulfilled the predefined criteria. Data presentation was adequate and showed moderate heterogeneity. The studies included 692 patients (21-178/study, mean age 61 years, 56% women). Analyzed were 688 ulcerated legs, present for 1 week to 9 years, sizing 1 to 210 cm(2). The observation period ranged from 12 to 78 weeks. Patient and ulcer characteristics were evenly distributed in three studies, favored the stocking groups in four, and the bandage group in one. Data on the pressure exerted by stockings and bandages were reported in seven and two studies, amounting to 31-56 and 27-49 mm Hg, respectively. The proportion of ulcers healed was greater with stockings than with bandages (62.7% vs 46.6%; P < .00001). The average time to healing (seven studies, 535 patients) was 3 weeks shorter with stockings (P = .0002). In no study performed bandages better than MCS. Pain was assessed in three studies (219 patients) revealing an important advantage of stockings (P < .0001). Other subjective parameters and issues of nursing revealed an advantage of MCS as well. Leg compression with stockings is clearly better than compression with bandages, has a positive impact on pain, and is easier to use.

  8. Nutation determination using the Global Positioning System

    NASA Astrophysics Data System (ADS)

    Yao, Kunliang; Capitaine, Nicole; Umnig, Elke; Weber, Robert

    2012-08-01

    VLBI observation of extragalactic radio sources is the only technique that allows high accuracy determination of nutation on a regular basis. However, this is limited to periods of nutation greater than about 30 days due to the current resolution of VL BI estimation. It is there fore important to use another technique to improve nutation at shorter periods. It has been shown by Rothacher et al. (1999) and Weber & Rothacher (2001) that GPS is a potential technique for the determination of the short period terms of nutation. The met hod, which is based on the estimation of nutation rates with respect to an a priori model, is limited to nutation terms in the higher frequency range (with periods up to about 21 days) due to deficiencies in the modeling of the satellite orbits. The high accuracy and high time resolution of the GPS observations that are now achieved give us the possibility to estimate the nutation variations with respect to the IAU2000A nutation, with an expected precision of 10 microarcseconds (μas ). The purpose of our study is to use recent GPS observations obtained by 140 IGS stations (IGS08 Core Reference Frame sites included) to estimate the short period nutations. Two methods are applied: one is to investigate the retrograde diurnal term of polar motion with nutation fixed to the IAU 2006/2000 precession - nutation, using CNES/GRGS software GINS/DYNAMO at Observatoire de Paris; another one is to investigate the nutation time derivative, with polar motion fixed, using Bernese GPS software at University of Technology in Vienna. In this poster, we report on our preliminary results with data set covering a period of 3 years (2009 - 2011), with appropriate time resolutions and on the comparison between the two approaches.

  9. The relationship between initial route of heroin administration and speed of transition to daily heroin use.

    PubMed

    Hines, Lindsey A; Lynskey, Michael; Morley, Katherine I; Griffiths, Paul; Gossop, Michael; Powis, Beverly; Strang, John

    2017-09-01

    The effect of heroin administration route on speed of transition to regular use is unknown. This paper aims to determine whether the speed of transition from initiation of heroin use to daily heroin use differs by route of administration (injecting, chasing/inhaling or snorting). Privileged access interviewer survey of purposively selected sample of 395 current people who use heroin (both in and not in treatment) in London, UK (historical sample from 1991). Data on age and year of initiation, time from initiation to daily use and routes of administration were collected by means of a structured questionnaire. Generalised ordered logistic models were used to test the relationship between route of initial administration of heroin and speed of transition to daily heroin use. Analyses were adjusted for gender, ethnicity, daily use of other drug(s) at time of initiation, year of initiation and treatment status at interview. After adjustment, participants whose initial administration route was injecting had a 4.71 (95% confidence interval 1.34-16.5) increase in likelihood of progressing to daily use within 1-3 weeks of initiation, compared to those whose initial administration route was non-injecting. The speed of transition from first use to daily heroin use is faster if the individual injects heroin at initiation of use. Those who initiate heroin use through injecting have a shorter time frame for intervention before drug use escalation. [Hines LA, Lynskey M, Morley KI, Griffiths P, Gossop M, Powis B, Strang J. The relationship between initial route of heroin administration and speed of transition to daily heroin use. Drug Alcohol Rev 2017;00:000-000]. © 2017 Australasian Professional Society on Alcohol and other Drugs.

  10. A novel concept for CT with fixed anodes (FACT): Medical imaging based on the feasibility of thermal load capacity.

    PubMed

    Kellermeier, Markus; Bert, Christoph; Müller, Reinhold G

    2015-07-01

    Focussing primarily on thermal load capacity, we describe the performance of a novel fixed anode CT (FACT) compared with a 100 kW reference CT. Being a fixed system, FACT has no focal spot blurring of the X-ray source during projection. Monte Carlo and finite element methods were used to determine the fluence proportional to thermal capacity. Studies of repeated short-time exposures showed that FACT could operate in pulsed mode for an unlimited period. A virtual model for FACT was constructed to analyse various temporal sequences for the X-ray source ring, representing a circular array of 1160 fixed anodes in the gantry. Assuming similar detector properties at a very small integration time, image quality was investigated using an image reconstruction library. Our model showed that approximately 60 gantry rounds per second, i.e. 60 sequential targetings of the 1160 anodes per second, were required to achieve a performance level equivalent to that of the reference CT (relative performance, RP = 1) at equivalent image quality. The optimal projection duration in each direction was about 10 μs. With a beam pause of 1 μs between projections, 78.4 gantry rounds per second with consecutive source activity were thermally possible at a given thermal focal spot. The settings allowed for a 1.3-fold (RP = 1.3) shorter scan time than conventional CT while maintaining radiation exposure and image quality. Based on the high number of rounds, FACT supports a high image frame rate at low doses, which would be beneficial in a wide range of diagnostic and technical applications. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  11. Associations Between Pharmacy Students’ Attitudes Toward Debt, Stress, and Student Loans

    PubMed Central

    Spivey, Christina A.; Jaeger, Melanie C.; Williams, Jennifer

    2017-01-01

    Objective. To assess graduating pharmacy students’ attitudes toward debt and determine associations with stress, student loan debt, financial need, current employment, post-graduation plans, and expected length of time to repay loans. Methods. Survey was conducted using an attitudes-toward-debt scale (sub-scales: tolerant attitudes toward debt; contemplation and knowledge about loans; fear of debt), Perceived Stress Scale, and questions concerning current employment, estimated total student loan debt, post-graduation plans, and expected length of time to repay loans. Federal loan data were collected using financial aid records. Independent samples t-test, ANOVA, and Pearson’s r correlations were conducted. Results. There were 147 students (96.7%) who participated. The majority were female (59.2%), white (69.4%), and had federal student loans (90.5%). Mean total loan amount was $153,276 (SD $59,810), which included federal students loans accumulated before and during pharmacy school. No significant differences were noted on attitudes toward debt or stress based on whether respondents had federal student loans. Greater “fear of debt” was correlated with increased stress, estimated total student loan debt, total federal loan debt, and pharmacy school loan debt. Greater “contemplation and knowledge about loans” was correlated with lower estimated total student loan debt, total federal loan amount, and pharmacy school loan amount. Students with higher “contemplation and knowledge” scores expected to repay loans within a shorter time frame than students with lower scores. Conclusion. Increased fear of debt was related to greater perceived stress and higher student loan amounts borrowed, while increased contemplation and knowledge about loans was associated with lower amounts borrowed. Educational programming concerning loans, debt, and personal financial management may help reduce stress and amount borrowed. PMID:29109558

  12. Chandra X-ray Time-Domain Study of Alpha Centauri AB, Procyon, and their Environs

    NASA Astrophysics Data System (ADS)

    Ayres, Thomas R.

    2018-06-01

    For more than a decade, Chandra X-ray Observatory has been monitoring the central AB binary (G2V+K1V) of the α Centauri triple system with semi-annual pointings, using the High-Resolution Camera. This study has been extended in recent years to the mid-F subgiant, Procyon. The main objective is to follow the coronal (T~1MK) activity variations of the three stars, analogous to the Sun's 11-year sunspot cycle. Tentative periods of 20 yr and 8 yr have been deduced for α Cen A and B, respectively; but so far Procyon has shown only a slow, very modest decline in count rate, which could well reflect a slight instrumental degradation rather than intrinsic behavior. The negligible high-energy variability of Procyon sits in stark contrast to the dramatic factor of several to ten changes in the X-ray luminosities of α Cen AB and the Sun over their respective cycles. Further, although sunlike α Cen A has been observed by successive generations of X-ray observatories for nearly four decades, albeit sporadically, there are key gaps in the coverage that affect the determination of the cycle period. In fact, the most recent pointings suggest a downturn in A's count rate that might be signaling a shorter, more solar-like cycle following a delayed minimum in the 2005--2010 time frame (perhaps an exaggerated version of the extended solar minimum between recent Cycles 23 and 24). Beyond the coronal cycles of the three stars, the sequence of periodic X-ray images represents a unique time-domain history concerning steady as well as variable sources in the two 30'x30' fields. The most conspicuous of the variable objects -- in the α Cen field -- will be described here.

  13. A medico-legal review of cases involving quadriplegia following cervical spine surgery: Is there an argument for a no-fault compensation system?

    PubMed

    Epstein, Nancy E

    2010-04-07

    To determine whether patients who become quadriplegic following cervical spine surgery are adequately compensated by our present medico-legal system. The outcomes of malpractice suits obtained from Verdict Search (East Islip, NY, USA), a medico-legal journal, were evaluated over a 20-year period. Although the present malpractice system generously rewards many quadriplegic patients with substantial settlements/ Plaintiffs' verdicts, a subset receive lesser reimbursements (verdicts/settlements], while others with defense verdicts receive no compensatory damages. Utilizing Verdict Search, 54 cases involving quadriplegia following cervical spine surgery were reviewed for a 20-year interval (1988-2008). The reason(s) for the suit, the defendants, the legal outcome, and the time to outcome were identified. Operations included 25 anterior cervical procedures, 22 posterior cervical operations, 1 circumferential cervical procedure, and 6 cases in which the cervical operations were not defined. The four most prominent legal allegations for suits included negligent surgery (47 cases), lack of informed consent (23 cases), failure to diagnose/treat (33 cases), and failure to brace (15 cases). Forty-four of the 54 suits included spine surgeons. There were 19 Plaintiffs' verdicts (average US $5.9 million, range US $540,000-US $18.4 million), and 20 settlements (average US $2.8 million, range US $66,500-US $12.0 million). Fifteen quadriplegic patients with defense verdicts received no compensatory damages. The average time to verdicts/settlements was 4.3 years. For 54 patients who were quadriplegic following cervical spine surgery, 15 (28%) with defense verdicts received no compensatory damages. Under a No-Fault system, quadriplegic patients would qualify for a "reasonable" level of compensation over a "shorter" time frame.

  14. Comparison of X-ray Radiation Process in Single and Nested Wire Array Implosions

    NASA Astrophysics Data System (ADS)

    Li, Z. H.; Xu, Z. P.; Yang, J. L.; Xu, R. K.; Guo, C.; Grabovsky, E. V.; Oleynic, G. M.; Smirnov, V. P.

    2006-01-01

    In order to understanding the difference between tungsten single-wire-array and tungsten nested-wire-array Z-pinches, we have measured the x-ray power, the temporal-spatial distributions of x-ray radiation from each of the two loads. The measurements were performed with 0.1mm spatial and 1 ns temporal resolutions at 2.5- and 3.5-MA currents. The experimental conditions, including wire material, number of wires, wire-array length, electrode design, and implosion time, remained unchanged from shot to shot. Analysis of the radiation power profiles suggests that the nested-wire-array radiate slightly less x-ray energy in relatively shorter time interval than the single wire-array, leading to a much greater x-ray power in nested-wire-array implosion. The temporal-spatial distributions of x-ray power show that in both cases, plasmas formed by wire-array ablation radiate not simultaneously along load axis. For nested-wire-array Z-pinch, plasmas near the anode begin to radiate in 2ns later than that near the cathode. As a contrast, the temporal divergence of radiation among different plasma zones of single-wire-array Z-pinch along Z-axis is more than 6ns. Measurements of the x-ray emissions from small segments of pinch (2mm length along axis) indicate that local radiation power profiles almost do not vary for the two loads. Photographs taken by X-ray framing camera give a same description about the radiation process of pinch. One may expect that, as a result of this study, if the single-wire-array can be redesigned so ingeniously that the x-rays are emitted at the same time all over the pinch zone, the radiation power of single wire array Z-pinch may be much greater than what have been achieved.

  15. Associations Between Pharmacy Students' Attitudes Toward Debt, Stress, and Student Loans.

    PubMed

    Chisholm-Burns, Marie A; Spivey, Christina A; Jaeger, Melanie C; Williams, Jennifer

    2017-09-01

    Objective. To assess graduating pharmacy students' attitudes toward debt and determine associations with stress, student loan debt, financial need, current employment, post-graduation plans, and expected length of time to repay loans. Methods. Survey was conducted using an attitudes-toward-debt scale (sub-scales: tolerant attitudes toward debt; contemplation and knowledge about loans; fear of debt), Perceived Stress Scale, and questions concerning current employment, estimated total student loan debt, post-graduation plans, and expected length of time to repay loans. Federal loan data were collected using financial aid records. Independent samples t -test, ANOVA, and Pearson's r correlations were conducted. Results. There were 147 students (96.7%) who participated. The majority were female (59.2%), white (69.4%), and had federal student loans (90.5%). Mean total loan amount was $153,276 (SD $59,810), which included federal students loans accumulated before and during pharmacy school. No significant differences were noted on attitudes toward debt or stress based on whether respondents had federal student loans. Greater "fear of debt" was correlated with increased stress, estimated total student loan debt, total federal loan debt, and pharmacy school loan debt. Greater "contemplation and knowledge about loans" was correlated with lower estimated total student loan debt, total federal loan amount, and pharmacy school loan amount. Students with higher "contemplation and knowledge" scores expected to repay loans within a shorter time frame than students with lower scores. Conclusion. Increased fear of debt was related to greater perceived stress and higher student loan amounts borrowed, while increased contemplation and knowledge about loans was associated with lower amounts borrowed. Educational programming concerning loans, debt, and personal financial management may help reduce stress and amount borrowed.

  16. Effects of Temporal Framing on Response to Antismoking Messages: The Mediating Role of Perceived Relevance.

    PubMed

    Zhao, Xiaoquan; Peterson, Emily

    2017-01-01

    This study tested the effect of temporal framing on young adult smokers' response to antismoking communication messages. In two studies using largely identical designs, young adult smokers recruited from a large university (n = 52) and Amazon Mechanical Turk (n = 210) were exposed to either no messages or messages featuring different temporal frames. Analysis of the combined data (N = 262) showed that framing the health consequences of smoking in a proximal (vs. distal) time frame led to greater perceived message relevance, less use of heuristic processing, greater use of systematic processing, greater positive affect, and more intense fear. Mediation analysis showed that perceived relevance was a significant mediator of the effect of temporal framing on message processing and emotional responses. In separate analysis of the Amazon Mechanical Turk data, the proximal frame also showed a consistent pattern of stronger impact on behavioral intentions compared to the distal frame, but the difference was only significant on the measure of intending to try to quit. Overall, findings of this study suggest that using proximal (vs. distal) frames may enhance receptivity to antismoking messages among young adult smokers, although the behavioral impact of this framing strategy still awaits further research.

  17. Race walking gait and its influence on race walking economy in world-class race walkers.

    PubMed

    Gomez-Ezeiza, Josu; Torres-Unda, Jon; Tam, Nicholas; Irazusta, Jon; Granados, Cristina; Santos-Concejero, Jordan

    2018-03-06

    The aim of this study was to determine the relationships between biomechanical parameters of the gait cycle and race walking economy in world-class Olympic race walkers. Twenty-One world-class race walkers possessing the Olympic qualifying standard participated in this study. Participants completed an incremental race walking test starting at 10 km·h -1 , where race walking economy (ml·kg -1 ·km -1 ) and spatiotemporal gait variables were analysed at different speeds. 20-km race walking performance was related to race walking economy, being the fastest race walkers those displaying reduced oxygen cost at a given speed (R = 0.760, p < 0.001). Longer ground contact times, shorter flight times, longer midstance sub-phase and shorter propulsive sub-phase during stance were related to a better race walking economy (moderate effect, p < 0.05). According to the results of this study, the fastest race walkers were more economi cal than the lesser performers. Similarly, shorter flight times are associated with a more efficient race walking economy. Coaches and race walkers should avoid modifying their race walking style by increasing flight times, as it may not only impair economy, but also lead to disqualification.

  18. Serial changes of humor comprehension for four-frame comic Manga: an fMRI study

    PubMed Central

    Osaka, Mariko; Yaoi, Ken; Minamoto, Takehiro; Osaka, Naoyuki

    2014-01-01

    Serial changes of humor comprehension evoked by a well organized four-frame comic Manga were investigated by fMRI in each step of humor comprehension. The neural substrates underlying the amusing effects in response to funny and mixed order manga were compared. In accordance with the time course of the four frames, fMRI activations changed serially. Beginning with the second frame (development scene), activation of the temporo-parietal junction (TPJ) was observed, followed by activations in the temporal and frontal areas during viewing of the third frame (turn scene). For the fourth frame (punch line), strong increased activations were confirmed in the medial prefrontal cortex (MPFC) and cerebellum. Interestingly, distinguishable activation differences in the cerebellum between funny and non-funny conditions were also found for the fourth frame. These findings suggest that humor comprehension evokes activation that initiates in the TPJ and expands to the MPFC and cerebellum at the convergence level. PMID:25059843

  19. High-resolution LCOS microdisplay with sub-kHz frame rate for high performance, high precision 3D sensor

    NASA Astrophysics Data System (ADS)

    Lazarev, Grigory; Bonifer, Stefanie; Engel, Philip; Höhne, Daniel; Notni, Gunther

    2017-06-01

    We report about the implementation of the liquid crystal on silicon (LCOS) microdisplay with 1920 by 1080 resolution and 720 Hz frame rate. The driving solution is FPGA-based. The input signal is converted from the ultrahigh-resolution HDMI 2.0 signal into HD frames, which follow with the specified 720 Hz frame rate. Alternatively the signal is generated directly on the FPGA with built-in pattern generator. The display is showing switching times below 1.5 ms for the selected working temperature. The bit depth of the addressed image achieves 8 bit within each frame. The microdisplay is used in the fringe projection-based 3D sensing system, implemented by Fraunhofer IOF.

  20. Time reversibility in the quantum frame

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Masot-Conde, Fátima

    2014-12-04

    Classic Mechanics and Electromagnetism, conventionally taken as time-reversible, share the same concept of motion (either of mass or charge) as the basis of the time reversibility in their own fields. This paper focuses on the relationship between mobile geometry and motion reversibility. The goal is to extrapolate the conclusions to the quantum frame, where matter and radiation behave just as elementary mobiles. The possibility that the asymmetry of Time (Time’s arrow) is an effect of a fundamental quantum asymmetry of elementary particles, turns out to be a consequence of the discussion.

  1. Digital movie-based on automatic titrations.

    PubMed

    Lima, Ricardo Alexandre C; Almeida, Luciano F; Lyra, Wellington S; Siqueira, Lucas A; Gaião, Edvaldo N; Paiva Junior, Sérgio S L; Lima, Rafaela L F C

    2016-01-15

    This study proposes the use of digital movies (DMs) in a flow-batch analyzer (FBA) to perform automatic, fast and accurate titrations. The term used for this process is "Digital movie-based on automatic titrations" (DMB-AT). A webcam records the DM during the addition of the titrant to the mixing chamber (MC). While the DM is recorded, it is decompiled into frames ordered sequentially at a constant rate of 26 frames per second (FPS). The first frame is used as a reference to define the region of interest (ROI) of 28×13pixels and the R, G and B values, which are used to calculate the Hue (H) values for each frame. The Pearson's correlation coefficient (r) is calculated between the H values of the initial frame and each subsequent frame. The titration curves are plotted in real time using the r values and the opening time of the titrant valve. The end point is estimated by the second derivative method. A software written in C language manages all analytical steps and data treatment in real time. The feasibility of the method was attested by application in acid/base test samples and edible oils. Results were compared with classical titration and did not present statistically significant differences when the paired t-test at the 95% confidence level was applied. The proposed method is able to process about 117-128 samples per hour for the test and edible oil samples, respectively, and its precision was confirmed by overall relative standard deviation (RSD) values, always less than 1.0%. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Adding moxifloxacin is associated with a shorter time to culture conversion in pulmonary tuberculosis.

    PubMed

    Wang, J-Y; Wang, J-T; Tsai, T-H; Hsu, C-L; Yu, C-J; Hsueh, P-R; Lee, L-N; Yang, P-C

    2010-01-01

    To investigate whether adding moxifloxacin (MXF) to the standard anti-tuberculosis regimen can shorten the time to sputum culture conversion in pulmonary tuberculosis (PTB). Adults with culture-positive PTB were divided into two treatment groups by their choice: standard regimen alone (HERZ group) and standard regimen plus daily 400 mg MXF in the first 2 months (MXF group). Sputum samples were collected thrice weekly in the first 8 weeks. The propensity score was calculated to estimate the conditional probability of entering the MXF group. Factors influencing time to culture conversion were investigated using Cox proportional hazards regression analysis stratified by propensity score. Sixty-two patients were enrolled in the MXF group and 88 in the HERZ group; respectively 51 and 72 completed the study. The regimen was modified before culture conversion in respectively 6 (12%) and 12 (16%; P = 0.47) patients, due to adverse effects. The time to culture conversion was shorter in the MXF group (HR 2.1, 95%CI 1.4-3.2). The culture conversion rate after 6 weeks of treatment was respectively 82% and 61% (P = 0.011, <0.05/4, calculated using the modified Bonferroni method). Adding MXF to the standard anti-tuberculosis regimen in the first 2 months was associated with a shorter time to culture conversion, a higher 6-week culture conversion rate and reduced transmission of tuberculosis.

  3. Developing a weighting strategy to include mobile phone numbers into an ongoing population health survey using an overlapping dual-frame design with limited benchmark information

    PubMed Central

    2014-01-01

    Background In 2012 mobile phone numbers were included into the ongoing New South Wales Population Health Survey (NSWPHS) using an overlapping dual-frame design. Previously in the NSWPHS the sample was selected using random digit dialing (RDD) of landline phone numbers. The survey was undertaken using computer assisted telephone interviewing (CATI). The weighting strategy needed to be significantly expanded to manage the differing probabilities of selection by frame, including that of children of mobile-only phone users, and to adjust for the increased chance of selection of dual-phone users. This paper describes the development of the final weighting strategy to properly combine the data from two overlapping sample frames accounting for the fact that population benchmarks for the different sampling frames were not available at the state or regional level. Methods Estimates of the number of phone numbers for the landline and mobile phone frames used to calculate the differing probabilities of selection by frame, for New South Wales (NSW) and by stratum, were obtained by apportioning Australian estimates as none were available for NSW. The weighting strategy was then developed by calculating person selection probabilities, selection weights, applying a constant composite factor to the dual-phone users sample weights, and benchmarking to the latest NSW population by age group, sex and stratum. Results Data from the NSWPHS for the first quarter of 2012 was used to test the weighting strategy. This consisted of data on 3395 respondents with 2171 (64%) from the landline frame and 1224 (36%) from the mobile frame. However, in order to calculate the weights, data needed to be available for all core weighting variables and so 3378 respondents, 2933 adults and 445 children, had sufficient data to be included. Average person weights were 3.3 times higher for the mobile-only respondents, 1.3 times higher for the landline-only respondents and 1.7 times higher for dual-phone users in the mobile frame compared to the dual-phone users in the landline frame. The overall weight effect for the first quarter of 2012 was 1.93 and the coefficient of variation of the weights was 0.96. The weight effects for 2012 were similar to, and in many cases less than, the effects found in the corresponding quarter of the 2011 NSWPHS when only a landline based sample was used. Conclusions The inclusion of mobile phone numbers, through an overlapping dual-frame design, improved the coverage of the survey and an appropriate weighing procedure is feasible, although it added substantially to the complexity of the weighting strategy. Access to accurate Australian, State and Territory estimates of the number of landline and mobile phone numbers and type of phone use by at least age group and sex would greatly assist in the weighting of dual-frame surveys in Australia. PMID:25189826

  4. Developing a weighting strategy to include mobile phone numbers into an ongoing population health survey using an overlapping dual-frame design with limited benchmark information.

    PubMed

    Barr, Margo L; Ferguson, Raymond A; Hughes, Phil J; Steel, David G

    2014-09-04

    In 2012 mobile phone numbers were included into the ongoing New South Wales Population Health Survey (NSWPHS) using an overlapping dual-frame design. Previously in the NSWPHS the sample was selected using random digit dialing (RDD) of landline phone numbers. The survey was undertaken using computer assisted telephone interviewing (CATI). The weighting strategy needed to be significantly expanded to manage the differing probabilities of selection by frame, including that of children of mobile-only phone users, and to adjust for the increased chance of selection of dual-phone users. This paper describes the development of the final weighting strategy to properly combine the data from two overlapping sample frames accounting for the fact that population benchmarks for the different sampling frames were not available at the state or regional level. Estimates of the number of phone numbers for the landline and mobile phone frames used to calculate the differing probabilities of selection by frame, for New South Wales (NSW) and by stratum, were obtained by apportioning Australian estimates as none were available for NSW. The weighting strategy was then developed by calculating person selection probabilities, selection weights, applying a constant composite factor to the dual-phone users sample weights, and benchmarking to the latest NSW population by age group, sex and stratum. Data from the NSWPHS for the first quarter of 2012 was used to test the weighting strategy. This consisted of data on 3395 respondents with 2171 (64%) from the landline frame and 1224 (36%) from the mobile frame. However, in order to calculate the weights, data needed to be available for all core weighting variables and so 3378 respondents, 2933 adults and 445 children, had sufficient data to be included. Average person weights were 3.3 times higher for the mobile-only respondents, 1.3 times higher for the landline-only respondents and 1.7 times higher for dual-phone users in the mobile frame compared to the dual-phone users in the landline frame. The overall weight effect for the first quarter of 2012 was 1.93 and the coefficient of variation of the weights was 0.96. The weight effects for 2012 were similar to, and in many cases less than, the effects found in the corresponding quarter of the 2011 NSWPHS when only a landline based sample was used. The inclusion of mobile phone numbers, through an overlapping dual-frame design, improved the coverage of the survey and an appropriate weighing procedure is feasible, although it added substantially to the complexity of the weighting strategy. Access to accurate Australian, State and Territory estimates of the number of landline and mobile phone numbers and type of phone use by at least age group and sex would greatly assist in the weighting of dual-frame surveys in Australia.

  5. Self-guide framing and persuasion: responsibly increasing message processing to ideal levels.

    PubMed

    Evans, Lisa M; Petty, Richard E

    2003-03-01

    The current research examines the effect that framing persuasive messages in terms of self-guides (ideal vs. ought) has on the attitudes and cognitive responses of individuals with chronic ideal versus ought self-guides. The strength of participants' ideal and ought self-guides and the magnitude of participants' ideal and ought self-discrepancies were measured using a computerized reaction time program. One week later, participants read a persuasive message about a fictional breakfast product, framed in terms of either ideals or oughts. Matching framing to stronger self-guide led to enhanced message processing activity, especially among individuals who were low in need for cognition. Individuals who read messages framed to match their stronger self-guides paid more attention to argument quality, as reflected in their attitudes and cognitive responses. Messages with self-guide framing that matched individuals' stronger self-discrepancies did not have this effect on processing.

  6. Low-energy laser in the treatment of alopecia of the scalp

    NASA Astrophysics Data System (ADS)

    Ciuchita, Tavi; Usurelu, Mircea; Antipa, Ciprian

    1997-12-01

    The authors tried to verify the efficacy of low energy laser (LEL) in scalp alopecia. Sixty patients were divided in two groups: A) laser group, 33 patients treated with both LEL and classical therapy; B) control group, 27 patients treated only with classical therapy, Before, during and after treatment, historical samples were done. For the group A the results were rather superior but in a twice shorter time shorter time than group B. The maintenance of the good results needed classical therapy for a long period. We conclude that LEL therapy could have a useful complementary method for the treatment of scalp alopecia.

  7. Cyclical Annealing Technique To Enhance Reliability of Amorphous Metal Oxide Thin Film Transistors.

    PubMed

    Chen, Hong-Chih; Chang, Ting-Chang; Lai, Wei-Chih; Chen, Guan-Fu; Chen, Bo-Wei; Hung, Yu-Ju; Chang, Kuo-Jui; Cheng, Kai-Chung; Huang, Chen-Shuo; Chen, Kuo-Kuang; Lu, Hsueh-Hsing; Lin, Yu-Hsin

    2018-02-26

    This study introduces a cyclical annealing technique that enhances the reliability of amorphous indium-gallium-zinc-oxide (a-IGZO) via-type structure thin film transistors (TFTs). By utilizing this treatment, negative gate-bias illumination stress (NBIS)-induced instabilities can be effectively alleviated. The cyclical annealing provides several cooling steps, which are exothermic processes that can form stronger ionic bonds. An additional advantage is that the total annealing time is much shorter than when using conventional long-term annealing. With the use of cyclical annealing, the reliability of the a-IGZO can be effectively optimized, and the shorter process time can increase fabrication efficiency.

  8. Palliation of clinical signs in 48 dogs with nasal carcinomas treated with coarse-fraction radiation therapy.

    PubMed

    Gieger, Tracy; Rassnick, Kenneth; Siegel, Sheri; Proulx, David; Bergman, Philip; Anderson, Christine; LaDue, Tracy; Smith, Annette; Northrup, Nicole; Roberts, Royce

    2008-01-01

    Data from 48 dogs with nasal carcinomas treated with palliative radiation therapy (PRT) were retrospectively reviewed. Factors potentially influencing resolution of clinical signs and survival after PRT were evaluated. Clinical signs completely resolved in 66% of dogs for a median of 120 days. The overall median survival time was 146 days. Duration of response to PRT was shorter in dogs that had clinical signs for <90 days before PRT. Survival times were shorter in dogs that had partial or no resolution of clinical signs after PRT than in dogs that had complete resolution of clinical signs.

  9. Anterior Cervical Corpectomy with free vascularized fibular graft versus multilevel discectomy and grafting for Cervical Spondylotic Myelopathy

    PubMed Central

    Addosooki, Ahmad I; El-deen, Mohamed Alam

    2015-01-01

    Purpose A retrospective study to compare the radiologic and clinical outcomes of 2 different anterior approaches, multilevel anterior cervical discectomy with fusion (ACDF) using autologus ticortical bone graft versus anterior cervical corpectomy with fusion (ACCF) using free vascularized fibular graft (FVFG) for the management of cervical spondylotic myelopathy(CSM). Methods A total of 15 patients who underwent ACDF or ACCF using FVFG for multilevel CSM were divided into two groups. Group A (n = 7) underwent ACDF and group B (n = 8) ACCF. Clinical outcomes using Japanese Orthopaedic Association (JOA) score, perioperative parameters including operation time and hospital stay, radiological parameters including fusion rate and cervical lordosis, and complications were compared. Results Both group A and group B demonstrated significant increases in JOA scores. Patients who underwent ACDF experienced significantly shorter operation times and hospital stay. Both groups showed significant increases in postoperative cervical lordosis and achieved the same fusion rate (100 %). No major complications were encountered in both groups. Conclusion Both ACDF and ACCF using FVFG provide satisfactory clinical outcomes and fusion rates for multilevel CSM. However, multilevel ACDF is associated with better radiologic parameters, shorter hospital stay and shorter operative times. PMID:26767152

  10. Using a Virtual Environment to Study Pedestrian Behaviors: How Does Time Pressure Affect Children's and Adults' Street Crossing Behaviors?

    PubMed

    Morrongiello, Barbara A; Corbett, Michael; Switzer, Jessica; Hall, Tom

    2015-08-01

    The aim of this study was to examine how crossing under time pressure influences the pedestrian behaviors of children and adults. Using a highly immersive virtual reality system interfaced with a 3D movement measurement system, various indices of children's and adults' crossing behaviors were measured under time-pressure and no time-pressure conditions. Pedestrians engaged in riskier crossing behaviors on time-pressure trials as indicated by appraising traffic for a shorter period before initiating their crossing, selecting shorter more hazardous temporal gaps to cross into, and having the car come closer to them (less time to spare). There were no age or sex differences in how time pressure affected crossing behaviors. The current findings indicate that, at all ages, pedestrians experience greater exposure to traffic dangers when they cross under time pressure. © The Author 2015. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Intervention on Surgical Systemic-to-Pulmonary Artery Shunts: Carotid Versus Femoral Access.

    PubMed

    Ligon, R Allen; Ooi, Yinn K; Kim, Dennis W; Vincent, Robert N; Petit, Christopher J

    2017-09-11

    The purpose of this study was to compare results between the femoral arterial (FA) and carotid arterial (CA) approaches in catheter-based interventions on Blalock-Taussig shunts (BTS). Transcatheter intervention on BTS is often performed in shunt-dependent, hypoxemic infants. The approach to BTS intervention likely has an impact on timeliness and overall success. The authors reviewed all cases of catheter intervention for BTS obstruction between 2012 and 2017 for their institution. They sought to compare procedural success rates and time, sheath time, time to arterial access, and time from access to stent implantation between FA and CA approaches. There were 42 BTS interventions between 34 patients. BTS intervention was more successful from the CA approach (p = 0.035). Among the FA cohort, BTS intervention was unsuccessful in 8 cases (25%), 5 of which were converted to CA with subsequent success. The CA cohort had lower procedure time (62 min vs. 104 min; p = 0.01) and anesthesia time (119 min vs. 151 min; p = 0.01). Additionally, CA access was associated with shorter time to arterial access (4.0 min vs. 9.3 min; p < 0.01), time to placement of the guidewire through the BTS (6.5 min vs. 13 min; p < 0.01), and time from the final sheath to BTS stent implantation (9 min vs. 20 min; p < 0.01). Operators should consider the route of access to the BTS deliberately. The authors' approach has been the carotid artery as an alternative access site-associated with greater procedural success, shorter procedural time, and shorter time to stent implantation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time

    PubMed Central

    Shinozaki, Satoshi; Miura, Yoshimasa; Ino, Yuji; Shinozaki, Kenjiro; Lefor, Alan Kawarai; Yamamoto, Hironori

    2015-01-01

    Background/Aims: Poor suction ability through a narrow working channel prolongs esophagogastroduodenoscopy (EGD). The aim of this study was to evaluate suction with a new ultrathin endoscope (EG-580NW2; Fujifilm Corp.) having a 2.4-mm working channel in clinical practice. Methods: To evaluate in vitro suction, 200 mL water was suctioned and the suction time was measured. The clinical data of 117 patients who underwent EGD were retrospectively reviewed on the basis of recorded video, and the suction time was measured by using a stopwatch. Results: In vitro, the suction time with the EG-580NW2 endoscope was significantly shorter than that with the use of an ultrathin endoscope with a 2.0-mm working channel (EG-580NW; mean ± standard deviation, 22.7±1.1 seconds vs. 34.7±2.2 seconds; p<0.001). We analyzed the total time and the suction time for routine EGD in 117 patients (50 in the EG-580NW2 group and 67 in the EG-580NW group). In the EG-580NW2 group, the total time for EGD was significantly shorter than that in the EG-580NW group (275.3±42.0 seconds vs. 300.6±46.5 seconds, p=0.003). In the EG-580NW2 group, the suction time was significantly shorter than that in the EG-580NW group (19.2±7.6 seconds vs. 38.0±15.9 seconds, p<0.001). Conclusions: An ultrathin endoscope with a 2.4-mm working channel considerably shortens the routine EGD time by shortening the suction time, in comparison with an endoscope with a 2.0-mm working channel. PMID:26668798

  13. High-frame rate multiport CCD imager and camera

    NASA Astrophysics Data System (ADS)

    Levine, Peter A.; Patterson, David R.; Esposito, Benjamin J.; Tower, John R.; Lawler, William B.

    1993-01-01

    A high frame rate visible CCD camera capable of operation up to 200 frames per second is described. The camera produces a 256 X 256 pixel image by using one quadrant of a 512 X 512 16-port, back illuminated CCD imager. Four contiguous outputs are digitally reformatted into a correct, 256 X 256 image. This paper details the architecture and timing used for the CCD drive circuits, analog processing, and the digital reformatter.

  14. Evaluation and optimization of the performance of frame geometries for lithium-ion battery application by computer simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miranda, D.; Instituto Politécnico de Viana do Castelo, Viana do Castelo; Miranda, F.

    2016-06-08

    Tailoring battery geometries is essential for many applications, as geometry influences the delivered capacity value. Two geometries, frame and conventional, have been studied and, for a given scan rate of 330C, the square frame shows a capacity value of 305,52 Ahm{sup −2}, which is 527 times higher than the one for the conventional geometry for a constant the area of all components.

  15. Framing of feedback impacts student's satisfaction, self-efficacy and performance.

    PubMed

    van de Ridder, J M Monica; Peters, Claudia M M; Stokking, Karel M; de Ru, J Alexander; Ten Cate, Olle Th J

    2015-08-01

    Feedback is considered important to acquire clinical skills. Research evidence shows that feedback does not always improve learning and its effects may be small. In many studies, a variety of variables involved in feedback provision may mask either one of their effects. E.g., there is reason to believe that the way oral feedback is framed may affect its effect if other variables are held constant. In a randomised controlled trial we investigated the effect of positively and negatively framed feedback messages on satisfaction, self-efficacy, and performance. A single blind randomised controlled between-subject design was used, with framing of the feedback message (positively-negatively) as independent variable and examination of hearing abilities as the task. First year medical students' (n = 59) satisfaction, self-efficacy, and performance were the dependent variables and were measured both directly after the intervention and after a 2 weeks delay. Students in the positively framed feedback condition were significantly more satisfied and showed significantly higher self-efficacy measured directly after the performance. Effect sizes found were large, i.e., partial η (2) = 0.43 and η (2) = 0.32 respectively. They showed a better performance throughout the whole study. Significant performance differences were found both at the initial performance and when measured 2 weeks after the intervention: effects were of medium size, respectively r = -.31 and r = -.32. Over time in both conditions performance and self-efficacy decreased. Framing the feedback message in either a positive or negative manner affects students' satisfaction and self-efficacy directly after the intervention be it that these effects seem to fade out over time. Performance may be enhanced by positive framing, but additional studies need to confirm this. We recommend using a positive frame when giving feedback on clinical skills.

  16. The Role of Bolus Injection of Saline with Arm Elevation on Rocuronium onset Time: A Randomized Control Study

    PubMed Central

    Kulkarni, Malavika; Chuchendra, L. S.; Bhavya, P. J.

    2018-01-01

    Background: The onset time of neuromuscular blockade is a crucial time associated with the risk of hypoxia and pulmonary aspiration. Various strategies have been undertaken to shorten this onset time. Therefore, we investigated the effects of bolus of 20 ml saline followed by limb elevation after administration of rocuronium in a dose of 0.6 mg/kg to study the onset time. Methodology: Thirty patients were randomly allocated to the bolus saline group or control group. General anesthesia was induced and maintained with fentanyl and propofol. Rocuronium 0.6 mg/kg intravenous (IV) was administered followed by 20 ml saline bolus and limb elevation in the study group compared to administration of 0.6 mg/kg in a running drip only in the control. Onset of neuromuscular block was assessed by acceleromyography at the adductor pollicis muscle with train-of-four stimulation. Results: The lag time was shorter in bolus group (34 s median) than in control group (45 s median), P < 0.017. The onset time was shorter in bolus group (55 s median) than in control group (110 s median), P < 0.001. The T1 recovery to 25% was longer in bolus group (42 min median) than in control group (39 min median) which was statistically not significant. Conclusion: Rocuronium 0.6 mg/kg IV followed by bolus 20 ml saline and concomitant limb elevation resulted in shorter lag time, faster onset of neuromuscular blockade, good intubating conditions without prolonging clinical duration of action when compared to the control. PMID:29628555

  17. Real-time image sequence segmentation using curve evolution

    NASA Astrophysics Data System (ADS)

    Zhang, Jun; Liu, Weisong

    2001-04-01

    In this paper, we describe a novel approach to image sequence segmentation and its real-time implementation. This approach uses the 3D structure tensor to produce a more robust frame difference signal and uses curve evolution to extract whole objects. Our algorithm is implemented on a standard PC running the Windows operating system with video capture from a USB camera that is a standard Windows video capture device. Using the Windows standard video I/O functionalities, our segmentation software is highly portable and easy to maintain and upgrade. In its current implementation on a Pentium 400, the system can perform segmentation at 5 frames/sec with a frame resolution of 160 by 120.

  18. Earth - South America (first frame of Earth Spin Movie)

    NASA Technical Reports Server (NTRS)

    1990-01-01

    This color image of the Earth was obtained by Galileo at about 6:10 a.m. Pacific Standard Time on Dec. 11, 1990, when the spacecraft was about 1.3 million miles from the planet during the first of two Earth flybys on its way to Jupiter. The color composite used images taken through the red, green and violet filters. South America is near the center of the picture, and the white, sunlit continent of Antarctica is below. Picturesque weather fronts are visible in the South Atlantic, lower right. This is the first frame of the Galileo Earth spin movie, a 500- frame time-lapse motion picture showing a 25-hour period of Earth's rotation and atmospheric dynamics.

  19. Independence of reaction time and response force control during isometric leg extension.

    PubMed

    Fukushi, Tamami; Ohtsuki, Tatsuyuki

    2004-04-01

    In this study, we examined the relative control of reaction time and force in responses of the lower limb. Fourteen female participants (age 21.2 +/- 1.0 years, height 1.62 +/- 0.05 m, body mass 54.1 +/- 6.1 kg; mean +/- s) were instructed to exert their maximal isometric one-leg extension force as quickly as possible in response to an auditory stimulus presented after one of 13 foreperiod durations, ranging from 0.5 to 10.0 s. In the 'irregular condition' each foreperiod was presented in random order, while in the 'regular condition' each foreperiod was repeated consecutively. A significant interactive effect of foreperiod duration and regularity on reaction time was observed (P < 0.001 in two-way ANOVA with repeated measures). In the irregular condition the shorter foreperiod induced a longer reaction time, while in the regular condition the shorter foreperiod induced a shorter reaction time. Peak amplitude of isometric force was affected only by the regularity of foreperiod and there was a significant variation of changes in peak force across participants; nine participants were shown to significantly increase peak force for the regular condition (P < 0.001), three to decrease it (P < 0.05) and two showed no difference. These results indicate the independence of reaction time and response force control in the lower limb motor system. Variation of changes in peak force across participants may be due to the different attention to the bipolar nature of the task requirements such as maximal force and maximal speed.

  20. Predicting the time of conversion to MCI in the elderly: role of verbal expression and learning.

    PubMed

    Oulhaj, Abderrahim; Wilcock, Gordon K; Smith, A David; de Jager, Celeste A

    2009-11-03

    Increasing awareness that minimal or mild cognitive impairment (MCI) in the elderly may be a precursor of dementia has led to an increase in the number of people attending memory clinics. We aimed to develop a way of predicting the period of time before cognitive impairment occurs in community-dwelling elderly. The method is illustrated by the use of simple tests of different cognitive domains. A cohort of 241 normal elderly volunteers was followed for up to 20 years with regular assessments of cognitive abilities using the Cambridge Cognitive Examination (CAMCOG); 91 participants developed MCI. We used interval-censored survival analysis statistical methods to model which baseline cognitive tests best predicted the time to convert to MCI. Out of several baseline variables, only age and CAMCOG subscores for expression and learning/memory were predictors of the time to conversion. The time to conversion was 14% shorter for each 5 years of age, 17% shorter for each point lower in the expression score, and 15% shorter for each point lower in the learning score. We present in tabular form the probability of converting to MCI over intervals between 2 and 10 years for different combinations of expression and learning scores. In apparently normal elderly people, subtle measurable cognitive deficits that occur within the normal range on standard testing protocols reliably predict the time to clinically relevant cognitive impairment long before clinical symptoms are reported.

Top