Sample records for shot count reduction

  1. Multi-Aperture-Based Probabilistic Noise Reduction of Random Telegraph Signal Noise and Photon Shot Noise in Semi-Photon-Counting Complementary-Metal-Oxide-Semiconductor Image Sensor

    PubMed Central

    Ishida, Haruki; Kagawa, Keiichiro; Komuro, Takashi; Zhang, Bo; Seo, Min-Woong; Takasawa, Taishi; Yasutomi, Keita; Kawahito, Shoji

    2018-01-01

    A probabilistic method to remove the random telegraph signal (RTS) noise and to increase the signal level is proposed, and was verified by simulation based on measured real sensor noise. Although semi-photon-counting-level (SPCL) ultra-low noise complementary-metal-oxide-semiconductor (CMOS) image sensors (CISs) with high conversion gain pixels have emerged, they still suffer from huge RTS noise, which is inherent to the CISs. The proposed method utilizes a multi-aperture (MA) camera that is composed of multiple sets of an SPCL CIS and a moderately fast and compact imaging lens to emulate a very fast single lens. Due to the redundancy of the MA camera, the RTS noise is removed by the maximum likelihood estimation where noise characteristics are modeled by the probability density distribution. In the proposed method, the photon shot noise is also relatively reduced because of the averaging effect, where the pixel values of all the multiple apertures are considered. An extremely low-light condition that the maximum number of electrons per aperture was the only 2e− was simulated. PSNRs of a test image for simple averaging, selective averaging (our previous method), and the proposed method were 11.92 dB, 11.61 dB, and 13.14 dB, respectively. The selective averaging, which can remove RTS noise, was worse than the simple averaging because it ignores the pixels with RTS noise and photon shot noise was less improved. The simulation results showed that the proposed method provided the best noise reduction performance. PMID:29587424

  2. Full counting statistics and shot noise of cotunneling in quantum dots and single-molecule transistors

    NASA Astrophysics Data System (ADS)

    Kaasbjerg, Kristen; Belzig, Wolfgang

    2015-06-01

    We develop a conceptually simple scheme based on a master-equation approach to evaluate the full-counting statistics (FCS) of elastic and inelastic off-resonant tunneling (cotunneling) in quantum dots (QDs) and molecules. We demonstrate the method by showing that it reproduces known results for the FCS and shot noise in the cotunneling regime. For a QD with an excited state, we obtain an analytic expression for the cumulant generating function (CGF) taking into account elastic and inelastic cotunneling. From the CGF we find that the shot noise above the inelastic threshold in the cotunneling regime is inherently super-Poissonian when external relaxation is weak. Furthermore, a complete picture of the shot noise across the different transport regimes is given. In the case where the excited state is a blocking state, strongly enhanced shot noise is predicted both in the resonant and cotunneling regimes.

  3. Practical proof of CP element based design for 14nm node and beyond

    NASA Astrophysics Data System (ADS)

    Maruyama, Takashi; Takita, Hiroshi; Ikeno, Rimon; Osawa, Morimi; Kojima, Yoshinori; Sugatani, Shinji; Hoshino, Hiromi; Hino, Toshio; Ito, Masaru; Iizuka, Tetsuya; Komatsu, Satoshi; Ikeda, Makoto; Asada, Kunihiro

    2013-03-01

    To realize HVM (High Volume Manufacturing) with CP (Character Projection) based EBDW, the shot count reduction is the essential key. All device circuits should be composed with predefined character parts and we call this methodology "CP element based design". In our previous work, we presented following three concepts [2]. 1) Memory: We reported the prospects of affordability for the CP-stencil resource. 2) Logic cell: We adopted a multi-cell clustering approach in the physical synthesis. 3) Random interconnect: We proposed an ultra-regular layout scheme using fixed size wiring tiles containing repeated tracks and cutting points at the tile edges. In this paper, we will report the experimental proofs in these methodologies. In full chip layout, CP stencil resource management is critical key. From the MCC-POC (Proof of Concept) result [1], we assumed total available CP stencil resource as 9000um2. We should manage to layout all circuit macros within this restriction. Especially the issues in assignment of CP-stencil resource for the memory macros are the most important as they consume considerable degree of resource because of the various line-ups such as 1RW-, 2RW-SRAMs, Resister Files and ROM which require several varieties of large size peripheral circuits. Furthermore the memory macros typically take large area of more than 40% of die area in the forefront logic LSI products so that the shot count increase impact is serious. To realize CP-stencil resource saving we had constructed automatic CP analyzing system. We developed two types of extraction mode of simple division by block and layout repeatability recognition. By properly controlling these models based upon each peripheral circuit characteristics, we could minimize the consumption of CP stencil resources. The estimation for 14nm technology node had been performed based on the analysis of practical memory compiler. The required resource for memory macro is proved to be affordable value which is 60% of full CP stencil resource and wafer level converted shot count is proved to be the level which meets 100WPH throughput. In logic cell design, circuit performance verification result after the cell clustering has been estimated. The cell clustering by the acknowledgment of physical distance proved to owe large penalty mainly in the wiring length. To reduce this design penalty, we proposed CP cell clustering by the acknowledgment of logical distance. For shot-count reduction of random interconnect area design, we proposed a more structural routing architecture which consists of the track exchange and the via position arrangement. Putting these design approaches together, we can design CP stencils to hit the target throughput within the area constraint. From the analysis for other macros such as analog, I/O, and DUMMY, it has proved that we don't need special CP design approach than legacy pattern matching CP extraction. From all these experimental results we get good prospects to the reality of full CP element based layout.

  4. Extraction and utilization of the repeating patterns for CP writing in mask making

    NASA Astrophysics Data System (ADS)

    Shoji, Masahiro; Inoue, Tadao; Yamabe, Masaki

    2010-05-01

    In May 2006, the Mask Design, Drawing, and Inspection Technology Research Department (Mask D2I) at the Association of Super-Advanced Electronics Technologies (ASET) launched a 4-year program for reducing mask manufacturing cost and TAT by concurrent optimization of Mask Data Preparation (MDP), mask writing, and mask inspection [1]. Figure 1 shows an outline of the project at Mask D2I at ASET. As one of the tasks being pursued at the Mask Design Data Technology Research Laboratory we have evaluated the effect of reducing the writing shot counts by utilizing the repeating patterns, and that showed positive impact on mask making by using CP writing. During the past four years, we have developed a software to extract repeating patterns from fractured OPCed mask data and have evaluated the efficiency of reducing the writing shot counts using the repeating patterns with this software. In this evaluation, we have used many actual device production data obtained from the member companies of Mask D2I. To the extraction software, we added new functions for extracting common repeating patterns from a set of multiple masks, and studied how this step affects the ratio of reducing the shot counts in comparison to the case of utilization of the repeating patterns for single mask. We have also developed a software that uses the result of extracting repeating patterns and prepares writing-data for the MCC/CP writing system which has been developed at the Mask Writing Equipment Technology Research Laboratory. With this software, we have examined how EB proximity effect on CP writing affects in reducing the shot count where CP shots with large CD errors have to be divided into VSB shots. In this paper we will report on making common CP mask from a set of multiple actual device data by using these software, and will also report on the results of CP writing and calculation of writing-TAT by MCC/CP writing system.

  5. Description of the Role of Shot Noise in Spectroscopic Absorption and Emission Measurements with Photodiode and Photomultiplier Tube Detectors: Information for an Instrumental Analysis Course

    ERIC Educational Resources Information Center

    McClain, Robert L.; Wright, John C.

    2014-01-01

    A description of shot noise and the role it plays in absorption and emission measurements using photodiode and photomultiplier tube detection systems is presented. This description includes derivations of useful forms of the shot noise equation based on Poisson counting statistics. This approach can deepen student understanding of a fundamental…

  6. Artifact reduction in the CSPAD detectors used for LCLS experiments.

    PubMed

    Pietrini, Alberto; Nettelblad, Carl

    2017-09-01

    The existence of noise and column-wise artifacts in the CSPAD-140K detector and in a module of the CSPAD-2.3M large camera, respectively, is reported for the L730 and L867 experiments performed at the CXI Instrument at the Linac Coherent Light Source (LCLS), in low-flux and low signal-to-noise ratio regime. Possible remedies are discussed and an additional step in the preprocessing of data is introduced, which consists of performing a median subtraction along the columns of the detector modules. Thus, we reduce the overall variation in the photon count distribution, lowering the mean false-positive photon detection rate by about 4% (from 5.57 × 10 -5 to 5.32 × 10 -5  photon counts pixel -1 frame -1 in L867, cxi86715) and 7% (from 1.70 × 10 -3 to 1.58 × 10 -3  photon counts pixel -1 frame -1 in L730, cxi73013), and the standard deviation in false-positive photon count per shot by 15% and 35%, while not making our average photon detection threshold more stringent. Such improvements in detector noise reduction and artifact removal constitute a step forward in the development of flash X-ray imaging techniques for high-resolution, low-signal and in serial nano-crystallography experiments at X-ray free-electron laser facilities.

  7. 7 CFR 51.885 - U.S. No. 1 Institutional.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... one variety, except when designated as assorted varieties, which are at least fairly well colored... cause. (f) Bunches not damaged by: (1) Shot berries; (2) Dried berries; (3) Other defective berries; (4... berries: Exclusive of shot berries and dried berries, 75 percent, by count, of the berries on each bunch...

  8. 7 CFR 51.885 - U.S. No. 1 Institutional.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... one variety, except when designated as assorted varieties, which are at least fairly well colored... cause. (f) Bunches not damaged by: (1) Shot berries; (2) Dried berries; (3) Other defective berries; (4... berries: Exclusive of shot berries and dried berries, 75 percent, by count, of the berries on each bunch...

  9. Designing to win in sub-90nm mask production

    NASA Astrophysics Data System (ADS)

    Zhang, Yuan

    2005-11-01

    An informal survey conducted with key customers by Photronics indicates that the time gap between technology nodes has accelerated in recent years. Previously the cycle was three years. However, between 130nm and 90nm there was less than a 2 year gap, and between 90nm and 65nm a 1.5 year gap exists. As a result, the technical challenges have increased substantially. In addition, mask costs are rising exponentially due to high capital equipment cost, a shrinking customer base, long write times and increased applications of 193nm EAPSM or AAPSM. Collaboration among EDA companies, mask houses and wafer manufacturers is now more important than ever. This paper will explore avenues for reducing mask costs, mainly in the areas of: write-time reduction through design for manufacturing (DFM), and yield improvement through specification relaxation. Our study conducted through layout vertex modeling suggests that a simple design shape such as a square versus a circle or an angled structure helps reduce shot count and write time. Shot count reduction through mask layout optimization, and advancement in new generation E-beam writers can reduce write time up to 65%. An advanced laser writer can produce those less critical E-beam layers in less than half the time of an e-beam writer. Additionally, the emerging imprint lithography brings new life and new challenges to the photomask industry with applications in many fields outside of the semiconductor industry. As immersion lithography is introduced for 45nm device production, polarization and MEEF effects due to the mask will become severe. Larger magnification not only provides benefits on CD control and MEEF, but also extends the life time of current 90nm/65nm tool sets where 45nm mask sets can be produced at a lower cost.

  10. 7 CFR 51.880 - U.S. Extra Fancy Table.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... U.S. Extra Fancy Table. “U.S. Extra Fancy Table” consists of bunches of well developed grapes of one... damaged by: (1) Shot berries; (2) Dried berries; (3) Other defective berries; (4) Trimming away of...) Size: (1) For berries: Exclusive of shot berries and dried berries, not less than 90 percent, by count...

  11. 7 CFR 51.880 - U.S. Extra Fancy Table.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... U.S. Extra Fancy Table. “U.S. Extra Fancy Table” consists of bunches of well developed grapes of one... damaged by: (1) Shot berries; (2) Dried berries; (3) Other defective berries; (4) Trimming away of...) Size: (1) For berries: Exclusive of shot berries and dried berries, not less than 90 percent, by count...

  12. 7 CFR 51.880 - U.S. Extra Fancy Table.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... U.S. Extra Fancy Table. “U.S. Extra Fancy Table” consists of bunches of well developed grapes of one... damaged by: (1) Shot berries; (2) Dried berries; (3) Other defective berries; (4) Trimming away of...) Size: (1) For berries: Exclusive of shot berries and dried berries, not less than 90 percent, by count...

  13. Design and fabrication of nano-imprint templates using unique pattern transforms and primitives

    NASA Astrophysics Data System (ADS)

    MacDonald, Susan; Mellenthin, David; Rentzsch, Kevin; Kramer, Kenneth; Ellenson, James; Hostetler, Tim; Enck, Ron

    2005-11-01

    Increasing numbers of MEMS, photonic, and integrated circuit manufacturers are investigating the use of Nano-imprint Lithography or Step and Flash Imprint Lithography (SFIL) as a lithography choice for making various devices and products. Their main interests in using these technologies are the lack of aberrations inherent in traditional optical reduction lithography, and the relative low cost of imprint tools. Since imprint templates are at 1X scale, the small sizes of these structures have necessitated the use of high-resolution 50KeV, and 100KeV e-beam lithography tools to build these templates. For MEMS and photonic applications, the structures desired are often circles, arches, and other non-orthogonal shapes. It has long been known that both 50keV, and especially 100keV e-beam lithography tools are extremely accurate, and can produce very high resolution structures, but the trade off is long write times. The main drivers in write time are shot count and stage travel. This work will show how circles and other non-orthogonal shapes can be produced with a 50KeV Variable Shaped Beam (VSB) e-beam lithography system using unique pattern transforms and primitive shapes, while keeping the shot count and write times under control. The quality of shapes replicated into the resist on wafer using an SFIL tool will also be presented.

  14. 7 CFR 51.884 - U.S. No. 1 Table.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Grades § 51.884 U.S. No. 1 Table. “U.S. No. 1 Table” consists of bunches of well developed grapes of one...) Mold; (2) Decay. (f) Berries not damaged by: (1) Any other cause. (g) Bunches not damaged by: (1) Shot...: Exclusive of shot berries and dried berries, 75 percent, by count, of the berries on each bunch shall have...

  15. 7 CFR 51.884 - U.S. No. 1 Table.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Grades § 51.884 U.S. No. 1 Table. “U.S. No. 1 Table” consists of bunches of well developed grapes of one...) Mold; (2) Decay. (f) Berries not damaged by: (1) Any other cause. (g) Bunches not damaged by: (1) Shot...: Exclusive of shot berries and dried berries, 75 percent, by count, of the berries on each bunch shall have...

  16. ON THE USE OF SHOT NOISE FOR PHOTON COUNTING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zmuidzinas, Jonas, E-mail: jonas@caltech.edu

    Lieu et al. have recently claimed that it is possible to substantially improve the sensitivity of radio-astronomical observations. In essence, their proposal is to make use of the intensity of the photon shot noise as a measure of the photon arrival rate. Lieu et al. provide a detailed quantum-mechanical calculation of a proposed measurement scheme that uses two detectors and conclude that this scheme avoids the sensitivity degradation that is associated with photon bunching. If correct, this result could have a profound impact on radio astronomy. Here I present a detailed analysis of the sensitivity attainable using shot-noise measurement schemesmore » that use either one or two detectors, and demonstrate that neither scheme can avoid the photon bunching penalty. I perform both semiclassical and fully quantum calculations of the sensitivity, obtaining consistent results, and provide a formal proof of the equivalence of these two approaches. These direct calculations are furthermore shown to be consistent with an indirect argument based on a correlation method that establishes an independent limit to the sensitivity of shot-noise measurement schemes. Furthermore, these calculations are directly applicable to the regime of interest identified by Lieu et al. Collectively, these results conclusively demonstrate that the photon-bunching sensitivity penalty applies to shot-noise measurement schemes just as it does to ordinary photon counting, in contradiction to the fundamental claim made by Lieu et al. The source of this contradiction is traced to a logical fallacy in their argument.« less

  17. Fracture Decoupling of Small Chemical Explosions in Granite and Limestone

    NASA Astrophysics Data System (ADS)

    Stroujkova, A. F.; Bonner, J. L.; Reinke, R.; Lenox, E. A.

    2012-12-01

    Reduction of the seismic amplitudes produced by underground explosions due to dissipation in a low-coupling medium poses a significant challenge for nuclear test monitoring. We examined the data from two experiments, which involved conducting explosions in the damage zone created by previous explosions ("repeat shots"). The first experiment was conducted in central New Hampshire in a fluid saturated granodiorite. The experiment involved detonating two 46 kg explosions: one in virgin rock and the other in the fractured rock zone produced by a larger (232 kg) explosion. The second experiment took place near Albuquerque, NM, in dry limestone. In this scenario the second explosion was conducted in the cavity created by the first explosion. Both limestone explosions had yields of 90.5 kg. The reduction of the seismic amplitudes was observed for both repeat shots: in granodiorite the amplitudes were reduced by a factor of 2-3, in limestone by a factor of 3-4 compared to the shots in the undamaged rocks. For the granodiorite repeat shot the decoupling ratios were frequency dependent with stronger amplitude reduction at higher frequencies. In addition, the virgin rock shot produced higher corner frequency and overshoot parameter than the repeat shot. For the limestone shot the decoupling ratios were nearly flat at all frequencies with similar corner frequencies. This observation suggests different mechanisms of energy dissipation for the two experiments.

  18. Effects of lead shot ingestion on selected cells of the mallard immune system

    USGS Publications Warehouse

    Rocke, T.E.; Samuel, M.D.

    1991-01-01

    The immunologic effects of lead were measured in game-farm mallards (Anas platyrhynchos) that ingested lead shot while foraging naturally, mallards intubated with lead shot, and unexposed controls. Circulating white blood cells (WBC) declined significantly in male mallards exposed to lead by either natural ingestion or intubation, but not females. Spleen plaque-forming cell (SPFC) counts were significantly lower in mallards intubated with lead pellets compared to controls. Declines in WBC and SPFC means with increasing tissue lead concentrations provide further evidence that lead exposure reduced immunologic cell numbers. Hormonal activity and diet may have influenced the immunologic effects of lead exposure in this study.

  19. Monitoring Hitting Load in Tennis Using Inertial Sensors and Machine Learning.

    PubMed

    Whiteside, David; Cant, Olivia; Connolly, Molly; Reid, Machar

    2017-10-01

    Quantifying external workload is fundamental to training prescription in sport. In tennis, global positioning data are imprecise and fail to capture hitting loads. The current gold standard (manual notation) is time intensive and often not possible given players' heavy travel schedules. To develop an automated stroke-classification system to help quantify hitting load in tennis. Nineteen athletes wore an inertial measurement unit (IMU) on their wrist during 66 video-recorded training sessions. Video footage was manually notated such that known shot type (serve, rally forehand, slice forehand, forehand volley, rally backhand, slice backhand, backhand volley, smash, or false positive) was associated with the corresponding IMU data for 28,582 shots. Six types of machine-learning models were then constructed to classify true shot type from the IMU signals. Across 10-fold cross-validation, a cubic-kernel support vector machine classified binned shots (overhead, forehand, or backhand) with an accuracy of 97.4%. A second cubic-kernel support vector machine achieved 93.2% accuracy when classifying all 9 shot types. With a view to monitoring external load, the combination of miniature inertial sensors and machine learning offers a practical and automated method of quantifying shot counts and discriminating shot types in elite tennis players.

  20. a Vacuum Ultraviolet Study of the Alcator C Tokamak Plasma Using a High Resolution, One-Dimensional Photon Counting Detector.

    NASA Astrophysics Data System (ADS)

    Benjamin, Russell D.

    A photon counting detector based on an image intensified photodiode array was developed to meet the needs of one particular area of spectroscopic study, the determination of the kinetic temperature of impurity species. The image intensifier incorporates 3 high strip current ( ~300 muA) microchannel plates in a 'Z' configuration to achieve the gain required for the detection of single photon events. The design, construction, and laboratory testing of this system to determine its suitability for fusion plasma diagnostics is described, in particular, the ability to measure emission line profiles in order to determine the kinetic temperature of the emitting species. The photon counting detector, mounted on the exit plane of a 1m Ebert-Fastie spectrometer, was used to make spectroscopic measurements of the local ion temperature in Alcator C plasmas using impurity emission lines. Alcator experiments on one particular method of RF heating in a tokamak plasma, the launching of Ion Bernstein waves (IBW), are discussed. The O V kinetic temperature increases during IBW injection as the pre-RF plasma density is raised (on a shot-to-shot basis) above the region in which significant increases in the central ion temperature are observed. In addition, ion temperature profiles were measured during Ion Bernstein wave experiments by combining this point derived from the fit to the emission line of O VII with neutral particle analyzer data. The incorporation of the O VII temperature point in the determination of the pre-RF ion temperature profile results in a significant reduction (~0.4 cm) in the characteristic width of this profile. The high resolution and geometric stability of the photon counting detector made possible the measurement of small wavelength shifts (Deltalambda ~ 0.01 A) and, therefore, the determination of small bulk plasma motions (in this case, poloidal rotation of the plasma) through the Doppler shift of impurity emission lines. The Zeeman effect makes a significant contribution to the measured line profile in high field tokamaks, even in the ultraviolet. Modelling of the Zeeman effect is discussed and applied to the impurity species observed in Alcator C plasmas. (Abstract shortened with permission of author.).

  1. An evaluation of the use of chlorine dioxide (Tristel One-Shot) in an automated washer/disinfector (Medivator) fitted with a chlorine dioxide generator for decontamination of flexible endoscopes.

    PubMed

    Coates, D

    2001-05-01

    Microbiological tests were carried out to evaluate a new chlorine dioxide sterilant: Tristel OneShot. Preliminary in vitro suspension tests showed that solutions containing around 140 ppm chlorine dioxide achieved a reduction factor exceeding 10(6) of Staphylococcus aureus in 1min and of Bacillus subtilis spores in 2.5 min in the presence of 3g/L bovine albumin. Subsequent tests evaluated the effectiveness of Tristel One-Shot in a Medivator washer/disinfector fitted with a Tristel Generator for processing flexible endoscopes. Each test run involved three stages. In the first, the instrument and air-water channels of a gastroscope were inoculated with a suspension of Pseudomonas aeruginosa (10(8)cfu/ml) in 10% sodium glutamate and serum (0, 5 or 10%) and then drained, partially dried, and saline flushed through for total viable counts (TVCs). In the second stage, the channels were re-inoculated with test organisms; detergent was flushed through the channels which were then brushed; and saline was flushed through for TVCs. In the third stage, the channels were re-inoculated; detergent was flushed through the channels which were then brushed; the endoscope was processed in the Medivator; and saline was flushed through for TVCs. Carrying out all three stages enabled determination of (1) the contribution played by manual cleaning of channels prior to processing in the Medivator, and (2) the combined effect of manual cleaning followed by processing. Two series of test runs were done. In the first, the Tristel Generator was set to generate 230ppm chlorine dioxide, and in the second 150ppm. In the first, cleaning followed by processing in the Medivator consistently achieved a >/= 10(6)-fold reduction of test organisms, and in the second a >/= 10(5)-fold reduction. Pre-cleaning of channels was very important-when done the initial concentration of serum in the inoculum (0-10%) had no affect on the results obtained after processing. Copyright 2001 The Hospital infection Society.

  2. Linear optical quantum metrology with single photons: Experimental errors, resource counting, and quantum Cramér-Rao bounds

    NASA Astrophysics Data System (ADS)

    Olson, Jonathan P.; Motes, Keith R.; Birchall, Patrick M.; Studer, Nick M.; LaBorde, Margarite; Moulder, Todd; Rohde, Peter P.; Dowling, Jonathan P.

    2017-07-01

    Quantum number-path entanglement is a resource for supersensitive quantum metrology and in particular provides for sub-shot-noise or even Heisenberg-limited sensitivity. However, such number-path entanglement is thought to have been resource intensive to create in the first place, typically requiring either very strong nonlinearities or nondeterministic preparation schemes with feedforward, which are difficult to implement. Recently [K. R. Motes et al., Phys. Rev. Lett. 114, 170802 (2015), 10.1103/PhysRevLett.114.170802], it was shown that number-path entanglement from a BosonSampling inspired interferometer can be used to beat the shot-noise limit. In this paper we compare and contrast different interferometric schemes, discuss resource counting, calculate exact quantum Cramér-Rao bounds, and study details of experimental errors.

  3. An optimized OPC and MDP flow for reducing mask write time and mask cost

    NASA Astrophysics Data System (ADS)

    Yang, Ellyn; Li, Cheng He; Park, Se Jin; Zhu, Yu; Guo, Eric

    2010-09-01

    In the process of optical proximity correction, layout edge or fragment is migrating to proper position in order to minimize edge placement error (EPE). During this fragment migration, several factors other than EPE can be also taken into account as a part of cost function for optimal fragment displacement. Several factors are devised in favor of OPC stability, which can accommodate room for high mask error enhancement factor (MEEF), lack of process window, catastrophic pattern failure such as pinch/bridge and improper fragmentation. As technology node becomes finer, there happens conflict between OPC accuracy and stability. Especially for metal layers, OPC has focused on the stability by loss of accurate OPC results. On this purpose, several techniques have been introduced, which are target smoothing, process window aware OPC, model-based retargeting and adaptive OPC. By utilizing those techniques, OPC enables more stabilized patterning, instead of realizing design target exactly on wafer. Inevitably, post-OPC layouts become more complicated because those techniques invoke additional edge, or fragments prior to correction or during OPC iteration. As a result, jogs of post OPC layer can be dramatically increased, which results in huge number of shot count after data fracturing. In other words, there is trade-off relationship between data complexity and various methods for OPC stability. In this paper, those relationships have been investigated with respect to several technology nodes. The mask shot count reduction is achieved by reducing the number of jogs with which EPE difference are within pre-specified value. The effect of jog smoothing on OPC output - in view of OPC performance and mask data preparation - was studied quantitatively for respective technology nodes.

  4. Electron-beam lithography with character projection technique for high-throughput exposure with line-edge quality control

    NASA Astrophysics Data System (ADS)

    Ikeno, Rimon; Maruyama, Satoshi; Mita, Yoshio; Ikeda, Makoto; Asada, Kunihiro

    2016-07-01

    The high throughput of character projection (CP) electron-beam (EB) lithography makes it a promising technique for low-to-medium volume device fabrication with regularly arranged layouts, such as for standard-cell logics and memory arrays. However, non-VLSI applications such as MEMS and MOEMS may not be able to fully utilize the benefits of the CP method due to the wide variety of layout figures including curved and oblique edges. In addition, the stepwise shapes that appear because of the EB exposure process often result in intolerable edge roughness, which degrades device performances. In this study, we propose a general EB lithography methodology for such applications utilizing a combination of the CP and variable-shaped beam methods. In the process of layout data conversion with CP character instantiation, several control parameters were optimized to minimize the shot count, improve the edge quality, and enhance the overall device performance. We have demonstrated EB shot reduction and edge-quality improvement with our methodology by using a leading-edge EB exposure tool, ADVANTEST F7000S-VD02, and a high-resolution hydrogen silsesquioxane resist. Atomic force microscope observations were used to analyze the resist edge profiles' quality to determine the influence of the control parameters used in the data conversion process.

  5. Single-Shot Laser Ablation Split-Stream (SS-LASS) Analysis Depth Profiling

    NASA Astrophysics Data System (ADS)

    Kylander-Clark, A. R.; Stearns, M. A.; Viete, D. R.; Cottle, J. M.; Hacker, B. R.

    2014-12-01

    Laser ablation depth profiling of geochronometers—such as zircon, monazite, titanite and rutile—has become popular in recent years as a tool to both determine date vs. depth or trace-element (TE) composition vs. depth; the former allows the dating of thin rims and, potentially, inversion of Pb-loss profiles for thermal histories, whereas the latter can yield insight into changes in PTX or mineral parageneses and inversion of trace-element profiles for thermal histories. In this study, we combine both techniques, enabling simultaneous acquisition of U-Th/Pb isotopic ratios and trace-element compositions, by joining a 193 nm excimer laser to a multi-collector ICP-MS and single-collector ICP-MS. The simultaneous acquisition allows direct shot-by-shot linkage between time and petrology, expanding our ability to understand the evolution of complex geologic systems. We construct each depth profile by capturing the analyte with a succession of individual laser pulses (each ~100 nm deep) . This has two main advantages over a typical time-dependent analysis of a multi-shot routine composed of tens to hundreds of shots and a several μm deep hole. 1) The reference material is analyzed between each shot for a more-accurate standardization of each aliquot of ablated material. 2) There is no mixing of material ablated from successive laser pulses during transmission to the ICP. The method is limited by count rate, which depends on spot size, excavation rate, instrument sensitivity, etc., and, for single-collector ICP, the switching time, which limits the number of elements that can be analyzed and their total counts. We explore the latter theoretically and experimentally to provide insight on both the ideal number of elements to measure and the dwell time in any given sample. Examples of the utility of SS-LASS include the comparison of apparent Pb loss to diffusion profiles of trace elements in rims of metamorphic rutile and titanite, as well as the determination of the timing and petrologic conditions of thin zircon rims in metamorphic rocks.

  6. Confined ion energy >200 keV and increased fusion yield in a DPF with monolithic tungsten electrodes and pre-ionization

    NASA Astrophysics Data System (ADS)

    Lerner, Eric J.; Hassan, Syed M.; Karamitsos, Ivana; Von Roessel, Fred

    2017-10-01

    To reduce impurities in the dense plasma focus FF-1 device, we used monolithic tungsten electrodes with pre-ionization. With this new set-up, we demonstrated a three-fold reduction of impurities by mass and a ten-fold reduction by ion number. FF-1 produced a 50% increase in fusion yield over our previous copper electrodes, both for a single shot and for a mean of ten consecutive shots with the same conditions. These results represent a doubling of fusion yield as compared with any other plasma focus device with the same 60 kJ energy input. In addition, FF-1 produced a new single-shot record of 240 ± 20 keV for mean ion energy, a record for any confined fusion plasma, using any device, and a 50% improvement in ten-shot mean ion energy. With a deuterium-nitrogen mix and corona-discharge pre-ionization, we were also able to reduce the standard deviation in the fusion yield to about 15%, a four-fold reduction over the copper-electrode results. We intend to further reduce impurities with new experiments using microwave treatment of tungsten electrodes, followed by the use of beryllium electrodes.

  7. Injection Drug Users' Perceived Barriers to Using Self-Initiated Harm Reduction Strategies.

    PubMed

    Bonar, Erin E; Rosenberg, Harold

    2014-08-01

    Increasing the frequency with which injecting drug users (IDUs) engage in self-initiated harm reduction strategies could improve their health, but few investigations have examined IDUs' perceived barriers to engaging in these behaviors. We interviewed 90 IDUs recruited from needle exchanges to assess: a) perceived obstacles to their use of two specific harm reduction strategies (i.e., test shots and pre-injection skin cleaning) designed to reduce two unhealthy outcomes (i.e., overdose and bacterial infections, respectively) and b) their use of other risk-reduction practices. The most frequently cited barrier for both test shots and skin cleaning was being in a rush to inject one's drugs. Other, less commonly cited barriers were strategy-specific (e.g., buying drugs from a known dealer as a reason not to do a test shot; not having access to cleaning supplies as a reason not to clean skin). Regarding other risk reduction practices, participants' most frequently reported using new or clean injecting supplies and avoiding sharing needles and injecting supplies. Some, but not all, of the barriers generated by participants in our study were similar to those frequently reported in other investigations, perhaps due to differences in the type of sample recruited or in the harm reduction behaviors investigated.

  8. Injection Drug Users’ Perceived Barriers to Using Self-Initiated Harm Reduction Strategies

    PubMed Central

    Rosenberg, Harold

    2014-01-01

    Introduction and Aims Increasing the frequency with which injecting drug users (IDUs) engage in self-initiated harm reduction strategies could improve their health, but few investigations have examined IDUs’ perceived barriers to engaging in these behaviors. Method We interviewed 90 IDUs recruited from needle exchanges to assess: a) perceived obstacles to their use of two specific harm reduction strategies (i.e., test shots and pre-injection skin cleaning) designed to reduce two unhealthy outcomes (i.e., overdose and bacterial infections, respectively) and b) their use of other risk-reduction practices. Results The most frequently cited barrier for both test shots and skin cleaning was being in a rush to inject one’s drugs. Other, less commonly cited barriers were strategy-specific (e.g., buying drugs from a known dealer as a reason not to do a test shot; not having access to cleaning supplies as a reason not to clean skin). Regarding other risk reduction practices, participants’ most frequently reported using new or clean injecting supplies and avoiding sharing needles and injecting supplies. Discussion and Conclusions Some, but not all, of the barriers generated by participants in our study were similar to those frequently reported in other investigations, perhaps due to differences in the type of sample recruited or in the harm reduction behaviors investigated. PMID:25419201

  9. A Fracture Decoupling Experiment

    NASA Astrophysics Data System (ADS)

    Stroujkova, A. F.; Bonner, J. L.; Leidig, M.; Ferris, A. N.; Kim, W.; Carnevale, M.; Rath, T.; Lewkowicz, J.

    2012-12-01

    Multiple observations made at the Semipalatinsk Test Site suggest that conducting nuclear tests in the fracture zones left by previous explosions results in decreased seismic amplitudes for the second nuclear tests (or "repeat shots"). Decreased seismic amplitudes reduce both the probability of detection and the seismically estimated yield of a "repeat shot". In order to define the physical mechanism responsible for the amplitude reduction and to quantify the degree of the amplitude reduction in fractured rocks, Weston Geophysical Corp., in collaboration with Columbia University's Lamont Doherty Earth Observatory, conducted a multi-phase Fracture Decoupling Experiment (FDE) in central New Hampshire. The FDE involved conducting explosions of various yields in the damage/fracture zones of previously detonated explosions. In order to quantify rock damage after the blasts we performed well logging and seismic cross-hole tomography studies of the source region. Significant seismic velocity reduction was observed around the source regions after the initial explosions. Seismic waves produced by the explosions were recorded at near-source and local seismic networks, as well as several regional stations throughout northern New England. Our analysis confirms frequency dependent seismic amplitude reduction for the repeat shots compared to the explosions in un-fractured rocks. The amplitude reduction is caused by pore closing and/or by frictional losses within the fractured media.

  10. Explosion Amplitude Reduction due to Fractures in Water-Saturated and Dry Granite

    NASA Astrophysics Data System (ADS)

    Stroujkova, A. F.; Leidig, M.; Bonner, J. L.

    2013-12-01

    Empirical observations made at the Semipalatinsk Test Site suggest that nuclear tests in the fracture zones left by previous explosions ('repeat shots') show reduced seismic amplitudes compared to the nuclear tests in virgin rocks. Likely mechanisms for the amplitude reduction in the repeat shots include increased porosity and reduced strength and elastic moduli, leading to pore closing and frictional sliding. Presence of pore water significantly decreases rock compressibility and strength, thus affecting seismic amplitudes. A series of explosion experiments were conducted in order to define the physical mechanism responsible for the amplitude reduction and to quantify the degree of the amplitude reduction in fracture zones of previously detonated explosions. Explosions in water-saturated granite were conducted in central New Hampshire in 2011 and 2012. Additional explosions in dry granite were detonated in Barre, VT in 2013. The amplitude reduction is different between dry and water-saturated crystalline rocks. Significant reduction in seismic amplitudes (by a factor of 2-3) in water-saturated rocks was achieved only when the repeat shot was detonated in the extensive damage zone created by a significantly larger (by a factor of 5) explosion. In case where the first and the second explosions were similar in yield, the amplitude reduction was relatively modest (5-20%). In dry rocks the amplitude reduction reached a factor of 2 even in less extensive damage zones. In addition there are differences in frequency dependence of the spectral amplitude ratios between explosions in dry and water-saturated rocks. Thus the amplitude reduction is sensitive to the extent of the damage zone as well as the pore water content.

  11. Full counting statistics in a serially coupled double quantum dot system with spin-orbit coupling

    NASA Astrophysics Data System (ADS)

    Wang, Qiang; Xue, Hai-Bin; Xie, Hai-Qing

    2018-04-01

    We study the full counting statistics of electron transport through a serially coupled double quantum dot (QD) system with spin-orbit coupling (SOC) weakly coupled to two electrodes. We demonstrate that the spin polarizations of the source and drain electrodes determine whether the shot noise maintains super-Poissonian distribution, and whether the sign transitions of the skewness from positive to negative values and of the kurtosis from negative to positive values take place. In particular, the interplay between the spin polarizations of the source and drain electrodes and the magnitude of the external magnetic field, can give rise to a gate-voltage-tunable strong negative differential conductance (NDC) and the shot noise in this NDC region is significantly enhanced. Importantly, for a given SOC parameter, the obvious variation of the high-order current cumulants as a function of the energy-level detuning in a certain range, especially the dip position of the Fano factor of the skewness can be used to qualitatively extract the information about the magnitude of the SOC.

  12. Self-Consistent Theory of Shot Noise Suppression in Ballistic Conductors

    NASA Astrophysics Data System (ADS)

    Bulashenko, O. M.; Rubí, J. M.; Kochelap, V. A.

    Shot-noise measurements become a fundamental tool to probe carrier interactions in mesoscopic systems [1]. A matter of particular interest is the significance of Coulomb interaction which may keep nearby electrons more regularly spaced rather than strictly at random and lead to the noise reduction. That effect occurs in different physical situations. Among them are charge-limited ballistic transport, resonant tunneling, single-electron tunneling, etc. In this communication we address the problem of Coulomb correlations in ballistic conductors under the space-charge-limited transport conditions, and present for the first time a semiclassical self-consistent theory of shot noise in these conductors by solving analytically the kinetic equation coupled self-consistently with a Poisson equation. Basing upon this theory, exact results for current noise in a two-terminal ballistic conductor under the action of long-range Coulomb correlations has been derived. The noise reduction factor (in respect to the uncorrelated value) is obtained in a closed analytical form for a full range of biases ranging from thermal to shot-noise limits which describe perfectly the results of the Monte Carlo simulations for a nondegenerate electron gas [2]. The magnitude of the noise reduction exceeds 0.01, which is of interest from the point of view of possible applications. Using these analytical results one may estimate a relative contribution to the noise from different groups of carriers (in energy space and/or real space) and to investigate in great detail the correlations between different groups of carriers. This leads us to suggest an electron energy spectroscopy experiment to probe the Coulomb correlations in ballistic conductors. Indeed, while the injected carriers are uncorrelated, those in the volume of the conductor are strongly correlated, as follows from the derived formulas for the fluctuation of the distribution function. Those correlations may be observed experimentally by making use of a combination of two already realized techniques: a hot-electron spectrometer [3,4] which allows one to analyze different energy groups of electrons collected at the contact and shot-noise measurements [5,6]. Such "shot noise reduction spectroscopy" allows one to measure the novel phenomena. In particular, we predict the (anti)correlation of the "tangent" electrons having the energy close to the potential barrier height, to all other electron energy groups collected at the receiving contact.

  13. LINEAR COUNT-RATE METER

    DOEpatents

    Henry, J.J.

    1961-09-01

    A linear count-rate meter is designed to provide a highly linear output while receiving counting rates from one cycle per second to 100,000 cycles per second. Input pulses enter a linear discriminator and then are fed to a trigger circuit which produces positive pulses of uniform width and amplitude. The trigger circuit is connected to a one-shot multivibrator. The multivibrator output pulses have a selected width. Feedback means are provided for preventing transistor saturation in the multivibrator which improves the rise and decay times of the output pulses. The multivibrator is connected to a diode-switched, constant current metering circuit. A selected constant current is switched to an averaging circuit for each pulse received, and for a time determined by the received pulse width. The average output meter current is proportional to the product of the counting rate, the constant current, and the multivibrator output pulse width.

  14. Estimating random errors due to shot noise in backscatter lidar observations.

    PubMed

    Liu, Zhaoyan; Hunt, William; Vaughan, Mark; Hostetler, Chris; McGill, Matthew; Powell, Kathleen; Winker, David; Hu, Yongxiang

    2006-06-20

    We discuss the estimation of random errors due to shot noise in backscatter lidar observations that use either photomultiplier tube (PMT) or avalanche photodiode (APD) detectors. The statistical characteristics of photodetection are reviewed, and photon count distributions of solar background signals and laser backscatter signals are examined using airborne lidar observations at 532 nm using a photon-counting mode APD. Both distributions appear to be Poisson, indicating that the arrival at the photodetector of photons for these signals is a Poisson stochastic process. For Poisson- distributed signals, a proportional, one-to-one relationship is known to exist between the mean of a distribution and its variance. Although the multiplied photocurrent no longer follows a strict Poisson distribution in analog-mode APD and PMT detectors, the proportionality still exists between the mean and the variance of the multiplied photocurrent. We make use of this relationship by introducing the noise scale factor (NSF), which quantifies the constant of proportionality that exists between the root mean square of the random noise in a measurement and the square root of the mean signal. Using the NSF to estimate random errors in lidar measurements due to shot noise provides a significant advantage over the conventional error estimation techniques, in that with the NSF, uncertainties can be reliably calculated from or for a single data sample. Methods for evaluating the NSF are presented. Algorithms to compute the NSF are developed for the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations lidar and tested using data from the Lidar In-space Technology Experiment.

  15. Estimating Random Errors Due to Shot Noise in Backscatter Lidar Observations

    NASA Technical Reports Server (NTRS)

    Liu, Zhaoyan; Hunt, William; Vaughan, Mark A.; Hostetler, Chris A.; McGill, Matthew J.; Powell, Kathy; Winker, David M.; Hu, Yongxiang

    2006-01-01

    In this paper, we discuss the estimation of random errors due to shot noise in backscatter lidar observations that use either photomultiplier tube (PMT) or avalanche photodiode (APD) detectors. The statistical characteristics of photodetection are reviewed, and photon count distributions of solar background signals and laser backscatter signals are examined using airborne lidar observations at 532 nm using a photon-counting mode APD. Both distributions appear to be Poisson, indicating that the arrival at the photodetector of photons for these signals is a Poisson stochastic process. For Poisson-distributed signals, a proportional, one-to-one relationship is known to exist between the mean of a distribution and its variance. Although the multiplied photocurrent no longer follows a strict Poisson distribution in analog-mode APD and PMT detectors, the proportionality still exists between the mean and the variance of the multiplied photocurrent. We make use of this relationship by introducing the noise scale factor (NSF), which quantifies the constant of proportionality that exists between the root-mean-square of the random noise in a measurement and the square root of the mean signal. Using the NSF to estimate random errors in lidar measurements due to shot noise provides a significant advantage over the conventional error estimation techniques, in that with the NSF uncertainties can be reliably calculated from/for a single data sample. Methods for evaluating the NSF are presented. Algorithms to compute the NSF are developed for the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) lidar and tested using data from the Lidar In-space Technology Experiment (LITE). OCIS Codes:

  16. Improvement of Surface Layer Characteristics by Shot Lining

    NASA Astrophysics Data System (ADS)

    Harada, Yasunori

    In the present study, lining of the metal with foils using shot peening was investigated to improve the surface layer characteristics. In the shot peening experiment, the foils set on the metal are pelted with hard particles traveling at a high velocity. The foils are bonded to the metal surface due to plastic deformation induced by the collision of the particles. The foils and the metal are heated to heighten the bondability because of the reduction of flow stress. Lining the metal with the hard powder sandwiched between two aluminum foil sheets was also attempted. In this experiment, a centrifugal shot peening machine wite an electrical heater was employed. The metals are commercially aluminium alloys and magnesium alloys, and the foils are commercially aluminum, titanium and nickel. The effects of shot speed and the heating temperature on the bondability were examined. Wear resistance was also evaluated by grinding. The foils were successfully bonded to the metal surface. It was found that the present method is effective in improving of surface layer characteristics.

  17. Sub-Poissonian light and photocurrent shot-noise suppression in closed opto-electronic loop

    NASA Technical Reports Server (NTRS)

    Masalov, A. V.; Putilin, A. A.; Vasilyev, Michael V.

    1994-01-01

    We examine experimentally photocurrent noise reduction in the opto-electronic closed loop. Photocurrent noise density 12.5 dB below the shot-noise was observed. So large suppression was not reached in previous experiments and cannot be explained in terms of an ordinary sub-Poissonian light in the loop. We propose the concept of anticorrelation state for the description of light in the loop.

  18. On the Path to SunShot: Advancing Concentrating Solar Power Technology Performance and Dispatchability.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mehos, Mark; Turchi, Craig; Jorgensen, Jennie

    2016-03-01

    Since the SunShot Vision Study (DOE 2012) was published, global deployment of concentrating solar power (CSP) has increased threefold to nearly 4,500 MW, with a similar threefold increase in operational capacity to 1,650 MW within the United States. Growth in U.S. CSP capacity has primarily been driven by policy support at the state and federal levels. State-driven renewable portfolio standards (RPSs), combined with a 30% federal investment tax credit (ITC) and federal loan guarantees, provided the opportunity for CSP developers to kick-start construction of CSP plants throughout the Southwest. Figure ES-1 demonstrates that deployment and private- and public-sector research andmore » development have led to dramatic cost reductions that have placed CSP well on the path to reaching the U.S. Department of Energy’s SunShot Initiative goal of 6 cents/kWh by 2020. In comparing the estimated capital costs from the SunShot Vision Study and the current analysis, we find that parabolic trough solar-field costs have fallen more rapidly than predicted, although the drop in solar-field costs was offset by the additional costs of moving from a wet-cooled power block in 2010 to a more expensive dry-cooled power block in 2015. The predicted 2015 decline in tower costs was in line with expectations, primarily driven by reduced heliostat costs. Figure ES-1 shows the reduction in levelized cost of electricity (LCOE) for both parabolic trough and tower systems, in addition to the projected 2020 SunShot target.« less

  19. Single-shot speckle reduction in numerical reconstruction of digitally recorded holograms.

    PubMed

    Hincapie, Diego; Herrera-Ramírez, Jorge; Garcia-Sucerquia, Jorge

    2015-04-15

    A single-shot method to reduce the speckle noise in the numerical reconstructions of electronically recorded holograms is presented. A recorded hologram with the dimensions N×M is split into S=T×T sub-holograms. The uncorrelated superposition of the individually reconstructed sub-holograms leads to an image with the speckle noise reduced proportionally to the 1/S law. The experimental results are presented to support the proposed methodology.

  20. Discrimination of shot-noise-driven Poisson processes by external dead time - Application of radioluminescence from glass

    NASA Technical Reports Server (NTRS)

    Saleh, B. E. A.; Tavolacci, J. T.; Teich, M. C.

    1981-01-01

    Ways in which dead time can be used to constructively enhance or diminish the effects of point processes that display bunching in the shot-noise-driven doubly stochastic Poisson point process (SNDP) are discussed. Interrelations between photocount bunching arising in the SNDP and the antibunching character arising from dead-time effects are investigated. It is demonstrated that the dead-time-modified count mean and variance for an arbitrary doubly stochastic Poisson point process can be obtained from the Laplace transform of the single-fold and joint-moment-generating functions for the driving rate process. The theory is in good agreement with experimental values for radioluminescence radiation in fused silica, quartz, and glass, and the process has many applications in pulse, particle, and photon detection.

  1. The influence of surface contamination on the ion emission from nanosecond-pulsed laser ablation of Al and Cu

    NASA Astrophysics Data System (ADS)

    Ullah, S.; Dogar, A. H.; Qayyum, H.; Rehman, Z. U.; Qayyum, A.

    2018-04-01

    Ions emitted from planar Al and Cu targets irradiated with a 1064 nm pulsed laser were investigated with the help of a time-resolving Langmuir probe. It was found that the intensity of the ions emitted from a target area rapidly decreases with the increasing number of laser shots, and seems to reach saturation after about 10 laser shots. The saturated intensity of Al and Cu ions was approximately 0.1 and 0.3 times the intensity of the respective ions measured at the first laser shot, respectively. The higher target ion intensity for the first few shots is thought to be due to the enhanced ionization of target atoms by vacuum-ultraviolet radiations emitted from the thermally excited/ionized surface contaminants. The reduction of target ion intensity with an increasing number of laser shots thus indicates the removal of contaminants from the irradiated surface area. Laser-cleaned Al and Cu surfaces were then allowed to be recontaminated with residual vacuum gases and the ion intensity was measured at various time delays. The prolonged exposure of the cleaned target to vacuum residual gases completely restores the ion intensity. Regarding surface contaminants removal, laser shots of higher intensities were found to be more effective than a higher number of laser shots having lower intensities.

  2. Illinois Kids Count: A Snap Shot of Our Future. County by County Profiles of Child Well-Being '92.

    ERIC Educational Resources Information Center

    Voices for Illinois Children, Chicago.

    This booklet presents statistics concerning the well-being of Illinois' 3.3 million children between 1980 and 1990. Statistics are compared county by county for each of the state's 102 counties, and statewide statistics are compared with those of the entire nation. A statewide analysis focuses on spending per pupil on education, the percentage of…

  3. Electron-beam lithography with character projection exposure for throughput enhancement with line-edge quality optimization

    NASA Astrophysics Data System (ADS)

    Ikeno, Rimon; Maruyama, Satoshi; Mita, Yoshio; Ikeda, Makoto; Asada, Kunihiro

    2016-03-01

    Among various electron-beam lithography (EBL) techniques, variable-shaped beam (VSB) and character projection (CP) methods have attracted many EBL users for their high-throughput feature, but they are considered to be more suited to small-featured VLSI fabrication with regularly-arranged layouts like standard-cell logics and memory arrays. On the other hand, non-VLSI applications like photonics, MEMS, MOEMS, and so on, have not been fully utilized the benefit of CP method due to their wide variety of layout patterns. In addition, the stepwise edge shapes by VSB method often causes intolerable edge roughness to degrade device characteristics from its intended performance with smooth edges. We proposed an overall EBL methodology applicable to wade-variety of EBL applications utilizing VSB and CP methods. Its key idea is in our layout data conversion algorithm that decomposes curved or oblique edges of arbitrary layout patterns into CP shots. We expect significant reduction in EB shot count with a CP-bordered exposure data compared to the corresponding VSB-alone conversion result. Several CP conversion parameters are used to optimize EB exposure throughput, edge quality, and resultant device characteristics. We demonstrated out methodology using the leading-edge VSB/CP EBL tool, ADVANTEST F7000S-VD02, with high resolution Hydrogen Silsesquioxane (HSQ) resist. Through our experiments of curved and oblique edge lithography under various data conversion conditions, we learned correspondence of the conversion parameters to the resultant edge roughness and other conditions. They will be utilized as the fundamental data for further enhancement of our EBL strategy for optimized EB exposure.

  4. On the Path to SunShot - The Role of Advancements in Solar Photovoltaic Efficiency, Reliability, and Costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodhouse, Michael; Jones-Albertus, Rebecca; Feldman, David

    2016-05-01

    Although tremendous progress has been made in reducing the cost of PV systems, additional LCOE reductions of 40%–50% between 2015 and 2020 will be required to reach the SunShot Initiative’s targets (see Woodhouse et al. 2016). Understanding the tradeoffs between installed prices and other PV system characteristics—such as module efficiency, module degradation rate, and system lifetime—are vital. For example, with 29%-efficient modules and high reliability (a 50-year lifetime and a 0.2%/year module degradation rate), a residential PV system could achieve the SunShot LCOE goal with modules priced at almost $1.20/W. But change the lifetime to 10 years and the degradationmore » rate to 2%/year, and the system would need those very high-efficiency modules at zero cost to achieve the same LCOE. Although these examples are extreme, they serve to illustrate the wide range of technological combinations that could help drive PV toward the LCOE goals. SunShot’s PV roadmaps illustrate specific potential pathways to the target cost reductions.« less

  5. The SunShot Initiative’s 2030 Goal: 3¢ per Kilowatt Hour for Solar Electricity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    In 2011, when solar power comprised less than 0.1% of the U.S. electricity supply, the U.S. Department of Energy (DOE) launched the SunShot Initiative with the goal of making solar electricity cost-competitive with traditionally generated electricity by 2020 without subsidies. At the time, this meant reducing photovoltaic (PV) and concentrating solar power (CSP) prices by approximately 75% across the residential, commercial, and utility-scale sectors. For utility-scale solar, this target is a levelized cost of energy (LCOE) of 6¢ per kilowatt hour (kWh)1. Rapid progress has been made in accelerating achievement of these cost reductions, and DOE’s Solar Energy Technologies Officemore » (SETO) sees clear pathways to meeting the SunShot 2020 cost targets on schedule.2 Enabled by the cost reductions to date, solar-generated electricity has become mainstream. In 2014 and 2015, solar represented about one-third of new electrical generating capacity installed in the United States Halfway through 2016, solar was supplying 1% of U.S. electricity demand and growing with an installed capacity of 30 gigawatts.« less

  6. Multiple echo multi-shot diffusion sequence.

    PubMed

    Chabert, Steren; Galindo, César; Tejos, Cristian; Uribe, Sergio A

    2014-04-01

    To measure both transversal relaxation time (T2 ) and diffusion coefficients within a single scan using a multi-shot approach. Both measurements have drawn interest in many applications, especially in skeletal muscle studies, which have short T2 values. Multiple echo single-shot schemes have been proposed to obtain those variables simultaneously within a single scan, resulting in a reduction of the scanning time. However, one problem with those approaches is the associated long echo read-out. Consequently, the minimum achievable echo time tends to be long, limiting the application of these sequences to tissues with relatively long T2 . To address this problem, we propose to extend the multi-echo sequences using a multi-shot approach, so that to allow shorter echo times. A multi-shot dual-echo EPI sequence with diffusion gradients and echo navigators was modified to include independent diffusion gradients in any of the two echoes. The multi-shot approach allows us to drastically reduce echo times. Results showed a good agreement for the T2 and mean diffusivity measurements with gold standard sequences in phantoms and in vivo data of calf muscles from healthy volunteers. A fast and accurate method is proposed to measure T2 and diffusion coefficients simultaneously, tested in vitro and in healthy volunteers. Copyright © 2013 Wiley Periodicals, Inc.

  7. Increased distance of shooting on basketball jump shot.

    PubMed

    Okazaki, Victor Hugo Alves; Rodacki, André Luiz Félix

    2012-01-01

    The present study analyzed the effect of increased distance on basketball jump shot outcome and performance. Ten male expert basketball players were filmed and a number of kinematic variables analyzed during jump shot that were performed from three conditions to represent close, intermediate and far distances (2.8, 4.6, and 6.4m, respectively). Shot accuracy decreased from 59% (close) to 37% (far), in function of the task constraints (p < 0.05). Ball release height decreased (p < 0.05) from 2.46 m (close) to 2.38m (intermediate) and to 2.33m (long). Release angle also decreased (p < 0.05) when shot was performed from close (78.92°) in comparison to intermediate distances (65.60°). While, ball release velocity increased (p < 0.05) from 4.39 m/s (close) to 5.75 m·s(-1) (intermediate) to 6.89 m·s(-1) (far). These changes in ball release height, angle and velocity, related to movement performance adaptations were suggested as the main factors that influence jump shot accuracy when distance is augmented. Key pointsThe increased distance leads to greater spatial con-straint over shot movement that demands an adapta-tion of the movement for the regulation of the accu-racy and the impulse generation to release the ball.The reduction in balls release height and release angle, in addition to the increase in balls release ve-locity, were suggested as the main factors that de-creased shot accuracy with the distance increased.Players should look for release angles of shooting that provide an optimal balls release velocity to im-prove accuracy.

  8. Comparison of Two Treatment Methods "One Shot" and "Sequential" on Reduction the Level of Hemoglobin in Patients with Percutaneous Nephrolithotripsy in Al Zahra Hospital in 2012-2013.

    PubMed

    Khorrami, Mohammad Hatef; Izadpanahi, Mohammad Hossein; Mohammadi, Mehrdad; Alizadeh, Farshid; Zargham, Mahtab; Khorrami, Farbod; Isfahani, Felora Farahini

    2017-01-01

    Access dilation is the most important part of percutaneous nephrolithotripsy (PCNL) that is done by different methods, especially metal telescoping and one shot. In this study, two different methods of access dilation one shot and telescoping were compared. In observational cross-sectional study, 240 patients who were a candidate for PCNL were selected and randomly divided into two groups. The first group was undergone one-shot method and the second group was undergone telescoping method. The decrease in hemoglobin (Hb), duration of hospitalization and the time of radiation exposure during access dilation was compared in two groups by SPSS software version 21, (SPSS Inc., Chicago, IL, USA). The decrease of Hb level after intervention in one-shot group was 1.08 ± 1.23 g/dl and in telescoping, group was 1.51 ± 1.08 g/dl with no difference statistically ( P = 0.37). The mean duration of hospitalization in one shot and telescoping group were 2.36 ± 0.67 and 2.28 ± 0.61 days, respectively. According to t -test, there was no significant difference between the two groups ( P = 0.37). Average radiation exposure in one shot group was 7.13 s and in telescoping, group was 35.75 s, and there was a significant difference between the two groups ( P < 0.001). One-shot method is superior to telescoping method due to less time for radiation exposure and no more blood loss and other complications during PCNL.

  9. Subradiant spontaneous undulator emission through collective suppression of shot noise

    DOE PAGES

    Ratner, D.; Hemsing, E.; Gover, A.; ...

    2015-05-01

    The phenomenon of Dicke’s subradiance, in which the collective properties of a system suppress radiation, has received broad interest in atomic physics. Recent theoretical papers in the field of relativistic electron beams have proposed schemes to achieve subradiance through suppression of shot noise current fluctuations. The resulting “quiet” beam generates less spontaneous radiation than emitted even by a shot noise beam when oscillating in an undulator. Quiet beams could have diverse accelerator applications, including lowering power requirements for seeded free-electron lasers and improving efficiency of hadron cooling. In this paper we present experimental observation of a strong reduction in undulatormore » radiation, demonstrating the feasibility of noise suppression as a practical tool in accelerator physics.« less

  10. Subradiant spontaneous undulator emission through collective suppression of shot noise

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ratner, D.; Hemsing, E.; Gover, A.

    The phenomenon of Dicke’s subradiance, in which the collective properties of a system suppress radiation, has received broad interest in atomic physics. Recent theoretical papers in the field of relativistic electron beams have proposed schemes to achieve subradiance through suppression of shot noise current fluctuations. The resulting “quiet” beam generates less spontaneous radiation than emitted even by a shot noise beam when oscillating in an undulator. Quiet beams could have diverse accelerator applications, including lowering power requirements for seeded free-electron lasers and improving efficiency of hadron cooling. In this paper we present experimental observation of a strong reduction in undulatormore » radiation, demonstrating the feasibility of noise suppression as a practical tool in accelerator physics.« less

  11. Stitching-error reduction in gratings by shot-shifted electron-beam lithography

    NASA Technical Reports Server (NTRS)

    Dougherty, D. J.; Muller, R. E.; Maker, P. D.; Forouhar, S.

    2001-01-01

    Calculations of the grating spatial-frequency spectrum and the filtering properties of multiple-pass electron-beam writing demonstrate a tradeoff between stitching-error suppression and minimum pitch separation. High-resolution measurements of optical-diffraction patterns show a 25-dB reduction in stitching-error side modes.

  12. Performance and capacity analysis of Poisson photon-counting based Iter-PIC OCDMA systems.

    PubMed

    Li, Lingbin; Zhou, Xiaolin; Zhang, Rong; Zhang, Dingchen; Hanzo, Lajos

    2013-11-04

    In this paper, an iterative parallel interference cancellation (Iter-PIC) technique is developed for optical code-division multiple-access (OCDMA) systems relying on shot-noise limited Poisson photon-counting reception. The novel semi-analytical tool of extrinsic information transfer (EXIT) charts is used for analysing both the bit error rate (BER) performance as well as the channel capacity of these systems and the results are verified by Monte Carlo simulations. The proposed Iter-PIC OCDMA system is capable of achieving two orders of magnitude BER improvements and a 0.1 nats of capacity improvement over the conventional chip-level OCDMA systems at a coding rate of 1/10.

  13. Evaluation of a near-infrared photomultiplier

    NASA Technical Reports Server (NTRS)

    Evans, W. E.

    1978-01-01

    A high performance near infrared sensitive photomultiplier tube was procured and evaluated with emphasis on those characteristics affecting its use over the very large amplitude range of signals encountered by an airborne lidar intended for mapping the distribution of stratospheric aerosols. A cathode quantum efficiency of 4.3 percent at 1.06 micrometer wavelength and a background count of less than 10,000 per second were realized. It is recommended that the tube be stored and operated at a temperature near -20 C, or cooler. Performance was found acceptable for the application in both pulse counting and analog modes, but careful design, probably including dynamic gain control, will be required to effectively utilize both modes on the same lidar shot.

  14. Bell pair creation in current of Kondo-correlated dot

    NASA Astrophysics Data System (ADS)

    Sakano, Rui; Oguri, Akira; Nishikawa, Yunori; Abe, Eisuke

    Recently, local-Fermi-liquid properties in non-linear currents and shot noises through the Kondo dot have been investigated both theoretically and experimentally. We suggest a new entangled-electron-pair generator utilizing mechanism of quasiparticle-pair creation which has been observed as enhancement of shot noise in the quantum dot. Using the renormalized perturbation theory for an orbital-degenerate impurity Anderson model and the full counting statistics, we calculate the Clauser-Horne-Shimony-Holt type Bell's correlator for currents through correlated two different channels of a Kondo correlated dot. It is shown that residual exchange-interactions of the local-Fermi-liquid create spin-entangled quasiparticle-pairs in nonlinear current and this results in violation of the Bell's inequality. This work was partially supported by JSPS KAKENHI Grant Numbers JP26220711, JP26400319, JP15K05181 and JP16K17723.

  15. SU-E-T-213: Comparison of Treatment Efficiency of Gamma Knife SRS Plans for Brain Metastases with Different Planning Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Y; Huang, Z; Lo, S

    2015-06-15

    Purpose: To improve Gamma Knife SRS treatment efficiency for brain metastases and compare the differences of treatment time and radiobiological effects between two different planning methods of automatic filling and manual placement of shots with inverse planning. Methods: T1-weighted MRI images with gadolinium contrast from five patients with a single brain metastatic-lesion were used in this retrospective study. Among them, two were from primary breast cancer, two from primary melanoma cancer and one from primary prostate cancer. For each patient, two plans were generated in Leksell GammaPlan10.1.1 for radiosurgical treatment with a Leksell GammaKnife Perfexion machine: one with automatic filling,more » automatic sector configuration and inverse optimization (Method1); and the other with manual placement of shots, manual setup of collimator sizes, manual setup of sector blocking and inverse optimization (Method2). Dosimetric quality of the plans was evaluated with parameters of Coverage, Selectivity, Gradient-Index and DVH. Beam-on Time, Number-of-Shots and Tumor Control Probability(TCP) were compared for the two plans while keeping their dosimetric quality very similar. Relative reduction of Beam-on Time and Number-of-Shots were calculated as the ratios among the two plans and used for quantitative analysis. Results: With very similar dosimetric and radiobiological plan quality, plans created with Method 2 had significantly reduced treatment time. Relative reduction of Beam-on Time ranged from 20% to 51 % (median:29%,p=0.001), and reduction of Number-of-Shots ranged from 5% to 67% (median:40%,p=0.0002), respectively. Time of plan creation for Method1 and Method2 was similar, approximately 20 minutes, excluding the time for tumor delineation. TCP calculated for the tumors from differential DVHs did not show significant difference between the two plans (p=0.35). Conclusion: The method of manual setup combined with inverse optimization in LGP for treatment of brain metastatic lesions with the Perfexion can achieve significantly higher time efficiency without degrading treatment quality.« less

  16. Effectiveness of Shot Peening In Suppressing Fatigue Cracking At Non-Metallic Inclusions In Udimet(Registered Trademark)720

    NASA Technical Reports Server (NTRS)

    Barrie, Robert L.; Gabb, Timothy P.; Telesman, Jack; Kantzos, Peter T.; Prescenzi, Anthony; Biles, T.; Bonacuse, P. J.

    2006-01-01

    The fatigue lives of modern powder metallurgy disk alloys can be reduced over an order of magnitude by cracking at inherent non-metallic inclusions. The objective of this work was to study the effectiveness of shot peening in suppressing LCF crack initiation and growth at surface nonmetallic inclusions. Inclusions were carefully introduced at elevated levels during powder metallurgy processing of the nickel-base disk superalloy Udimet 720. Multiple strain-controlled fatigue tests were then performed on machined specimens with and without shot peened test sections at 427 C and 650 C. The low cycle fatigue lives and failure initiation sites varied as functions of inclusion content, shot peening, and fatigue conditions. A large majority of the failures in as-machined specimens with the introduced inclusions occurred at cracks initiating from inclusions intersecting the specimen surface. These inclusions reduced fatigue life by up to 100X, when compared to lives of material without inclusions residing at specimen surface. Large inclusions produced the greatest reductions in life for tests at low strain ranges and high strain ratios. Shot peening improved life in many cases by reducing the most severe effects of inclusions.

  17. Model-based MPC enables curvilinear ILT using either VSB or multi-beam mask writers

    NASA Astrophysics Data System (ADS)

    Pang, Linyong; Takatsukasa, Yutetsu; Hara, Daisuke; Pomerantsev, Michael; Su, Bo; Fujimura, Aki

    2017-07-01

    Inverse Lithography Technology (ILT) is becoming the choice for Optical Proximity Correction (OPC) of advanced technology nodes in IC design and production. Multi-beam mask writers promise significant mask writing time reduction for complex ILT style masks. Before multi-beam mask writers become the main stream working tools in mask production, VSB writers will continue to be the tool of choice to write both curvilinear ILT and Manhattanized ILT masks. To enable VSB mask writers for complex ILT style masks, model-based mask process correction (MB-MPC) is required to do the following: 1). Make reasonable corrections for complex edges for those features that exhibit relatively large deviations from both curvilinear ILT and Manhattanized ILT designs. 2). Control and manage both Edge Placement Errors (EPE) and shot count. 3. Assist in easing the migration to future multi-beam mask writer and serve as an effective backup solution during the transition. In this paper, a solution meeting all those requirements, MB-MPC with GPU acceleration, will be presented. One model calibration per process allows accurate correction regardless of the target mask writer.

  18. Comparison of muzzle suppression and ear-level hearing protection in firearm use.

    PubMed

    Branch, Matthew Parker

    2011-06-01

    To compare noise reduction of commercially available ear-level hearing protection (muffs/inserts) to that of firearm muzzle suppressors. Experimental sound measurements under consistent environmental conditions. None. Muzzle suppressors for 2 pistol and 2 rifle calibers were tested using the Bruel & Kjaer 2209 sound meter and Bruel & Kjaer 4136 microphone calibrated with the Bruel & Kjaer Pistonphone using Military-Standard 1474D placement protocol. Five shots were recorded unsuppressed and 10 shots suppressed under consistent environmental conditions. Sound reduction was then compared with the real-world noise reduction rate of the best available ear-level protectors. All suppressors offered significantly greater noise reduction than ear-level protection, usually greater than 50% better. Noise reduction of all ear-level protectors is unable to reduce the impulse pressure below 140 dB for certain common firearms, an international standard for prevention of sensorineural hearing loss. Modern muzzle-level suppression is vastly superior to ear-level protection and the only available form of suppression capable of making certain sporting arms safe for hearing. The inadequacy of standard hearing protectors with certain common firearms is not recognized by most hearing professionals or their patients and should affect the way hearing professionals counsel patients and the public.

  19. Lead poisoning of passerines at a trap and skeet range

    USGS Publications Warehouse

    Vyas, N.B.; Spann, J.W.; Heinz, G.H.; Beyer, W.N.; Jaquette, J.A.; Mengelkoch, J.M.

    2000-01-01

    Our objective was to determine if ground foraging passerines in a woodland surrounding a trap and skeet range were subject to lead poisoning. Lead availability to birds was determined by shot counts and soil and earthworm analysis. Avian exposure to lead was identified by measuring free-erythrocyte protoporphyrin levels in blood and lead in tissues of three passerine species. Results showed that most shot were found in the top 3 cm of soil. Lead measurements ranged from 110 to 27,000 ppm (dry wt) in soil and were 660 and 840 ppm in earthworms. Sparrows held in an aviary at the range (p = 0.02) and free-flying juncos (p = 0.0005) mistnetted at the range displayed significantly higher protoporphyrin levels than those at an uncontaminated site. Sparrow and cowbird carcasses from the aviary carried 37 and 39 ppm lead (dry wt), respectively, whereas a junco liver contained 9.3 ppm lead.

  20. Real-time passenger counting by active linear cameras

    NASA Astrophysics Data System (ADS)

    Khoudour, Louahdi; Duvieubourg, Luc; Deparis, Jean-Pierre

    1996-03-01

    The companies operating subways are very much concerned with counting the passengers traveling through their transport systems. One of the most widely used systems for counting passengers consists of a mechanical gate equipped with a counter. However, such simple systems are not able to count passengers jumping above the gates. Moreover, passengers carrying large luggage or bags may meet some difficulties when going through such gates. The ideal solution is a contact-free counting system that would bring more comfort of use for the passengers. For these reasons, we propose to use a video processing system instead of these mechanical gates. The optical sensors discussed in this paper offer several advantages including well defined detection areas, fast response time and reliable counting capability. A new technology has been developed and tested, based on linear cameras. Preliminary results show that this system is very efficient when the passengers crossing the optical gate are well separated. In other cases, such as in compact crowd conditions, reasonable accuracy has been demonstrated. These results are illustrated by means of a number of sequences shot in field conditions. It is our belief that more precise measurements could be achieved, in the case of compact crowd, by other algorithms and acquisition techniques of the line images that we are presently developing.

  1. The BOS-X approach: achieving drastic cost reduction in CPV through holistic power plant level innovation

    NASA Astrophysics Data System (ADS)

    Plesniak, A.; Garboushian, V.

    2012-10-01

    In 2011, the Amonix Advanced Technology Group was awarded DOE SunShot funding in the amount of 4.5M to design a new Balance of System (BOS) architecture utilizing Amonix MegaModules™ focused on reaching the SunShot goal of 0.06-$0.08/kWhr LCOE. The project proposal presented a comprehensive re-evaluation of the cost components of a utility scale CPV plant and identified critical areas of focus where innovation is needed to achieve cost reduction. As the world's premier manufacturer and most experienced installer of CPV power plants, Amonix is uniquely qualified to lead a rethinking of BOS architecture for CPV. The presentation will focus on the structure of the BOS-X approach, which looks for the next wave of cost reduction in CPV through evaluation of non-module subsystems and the interaction between subsystems during the lifecycle of a solar power plant. Innovation around nonmodule components is minimal to date because CPV companies are just now getting enough practice through completion of large projects to create ideas and tests on how to improve baseline designs and processes. As CPV companies increase their installed capacity, they can utilize an approach similar to the methodology of BOS-X to increase the competitiveness of their product. Through partnership with DOE, this holistic approach is expected to define a path for CPV well aligned with the goals of the SunShot Initiative.

  2. Electron beam mask writer EBM-9500 for logic 7nm node generation

    NASA Astrophysics Data System (ADS)

    Matsui, Hideki; Kamikubo, Takashi; Nakahashi, Satoshi; Nomura, Haruyuki; Nakayamada, Noriaki; Suganuma, Mizuna; Kato, Yasuo; Yashima, Jun; Katsap, Victor; Saito, Kenichi; Kobayashi, Ryoei; Miyamoto, Nobuo; Ogasawara, Munehiro

    2016-10-01

    Semiconductor scaling is slowing down because of difficulties of device manufacturing below logic 7nm node generation. Various lithography candidates which include ArF immersion with resolution enhancement technology (like Inversed Lithography technology), Extreme Ultra Violet lithography and Nano Imprint lithography are being developed to address the situation. In such advanced lithography, shot counts of mask patterns are estimated to increase explosively in critical layers, and then it is hoped that multi beam mask writer (MBMW) is released to handle them within realistic write time. However, ArF immersion technology with multiple patterning will continue to be a mainstream lithography solution for most of the layers. Then, the shot counts in less critical layers are estimated to be stable because of the limitation of resolution in ArF immersion technology. Therefore, single beam mask writer (SBMW) can play an important role for mask production still, relative to MBMW. Also the demand of SBMW seems actually strong for the logic 7nm node. To realize this, we have developed a new SBMW, EBM-9500 for mask fabrication in this generation. A newly introduced electron beam source enables higher current density of 1200A/cm2. Heating effect correction function has also been newly introduced to satisfy the requirements for both pattern accuracy and throughput. In this paper, we will report the configuration and performance of EBM-9500.

  3. Resolution enhancement in integral microscopy by physical interpolation.

    PubMed

    Llavador, Anabel; Sánchez-Ortiga, Emilio; Barreiro, Juan Carlos; Saavedra, Genaro; Martínez-Corral, Manuel

    2015-08-01

    Integral-imaging technology has demonstrated its capability for computing depth images from the microimages recorded after a single shot. This capability has been shown in macroscopic imaging and also in microscopy. Despite the possibility of refocusing different planes from one snap-shot is crucial for the study of some biological processes, the main drawback in integral imaging is the substantial reduction of the spatial resolution. In this contribution we report a technique, which permits to increase the two-dimensional spatial resolution of the computed depth images in integral microscopy by a factor of √2. This is made by a double-shot approach, carried out by means of a rotating glass plate, which shifts the microimages in the sensor plane. We experimentally validate the resolution enhancement as well as we show the benefit of applying the technique to biological specimens.

  4. Resolution enhancement in integral microscopy by physical interpolation

    PubMed Central

    Llavador, Anabel; Sánchez-Ortiga, Emilio; Barreiro, Juan Carlos; Saavedra, Genaro; Martínez-Corral, Manuel

    2015-01-01

    Integral-imaging technology has demonstrated its capability for computing depth images from the microimages recorded after a single shot. This capability has been shown in macroscopic imaging and also in microscopy. Despite the possibility of refocusing different planes from one snap-shot is crucial for the study of some biological processes, the main drawback in integral imaging is the substantial reduction of the spatial resolution. In this contribution we report a technique, which permits to increase the two-dimensional spatial resolution of the computed depth images in integral microscopy by a factor of √2. This is made by a double-shot approach, carried out by means of a rotating glass plate, which shifts the microimages in the sensor plane. We experimentally validate the resolution enhancement as well as we show the benefit of applying the technique to biological specimens. PMID:26309749

  5. Serious Hazards of Transfusion (SHOT) haemovigilance and progress is improving transfusion safety

    PubMed Central

    Bolton-Maggs, Paula H B; Cohen, Hannah

    2013-01-01

    Summary The Serious Hazards of Transfusion (SHOT) UK confidential haemovigilance reporting scheme began in 1996. Over the 16 years of reporting, the evidence gathered has prompted changes in transfusion practice from the selection and management of donors to changes in hospital practice, particularly better education and training. However, half or more reports relate to errors in the transfusion process despite the introduction of several measures to improve practice. Transfusion in the UK is very safe: 2·9 million components were issued in 2012, and very few deaths are related to transfusion. The risk of death from transfusion as estimated from SHOT data in 2012 is 1 in 322 580 components issued and for major morbidity, 1 in 21 413 components issued; the risk of transfusion-transmitted infection is much lower. Acute transfusion reactions and transfusion-associated circulatory overload carry the highest risk for morbidity and death. The high rate of participation in SHOT by National Health Service organizations, 99·5%, is encouraging. Despite the very useful information gained about transfusion reactions, the main risks remain human factors. The recommendations on reduction of errors through a ‘back to basics’ approach from the first annual SHOT report remain absolutely relevant today. PMID:24032719

  6. Broadband 2D electronic spectrometer using white light and pulse shaping: noise and signal evaluation at 1 and 100 kHz.

    PubMed

    Kearns, Nicholas M; Mehlenbacher, Randy D; Jones, Andrew C; Zanni, Martin T

    2017-04-03

    We have developed a broad bandwidth two-dimensional electronic spectrometer that operates shot-to-shot at repetition rates up to 100 kHz using an acousto-optic pulse shaper. It is called a two-dimensional white-light (2D-WL) spectrometer because the input is white-light supercontinuum. Methods for 100 kHz data collection are studied to understand how laser noise is incorporated into 2D spectra during measurement. At 100 kHz, shot-to-shot scanning of the delays and phases of the pulses in the pulse sequence produces a 2D spectrum 13-times faster and with the same signal-to-noise as using mechanical stages and a chopper. Comparing 100 to 1 kHz repetition rates, data acquisition time is decreased by a factor of 200, which is beyond the improvement expected by the repetition rates alone due to reduction in 1/f noise. These improvements arise because shot-to-shot readout and modulation of the pulse train at 100 kHz enables the electronic coherences to be measured faster than the decay in correlation between laser intensities. Using white light supercontinuum for the pump and probe pulses produces high signal-to-noise spectra on samples with optical densities <0.1 within a few minutes of averaging and an instrument response time of <46 fs thereby demonstrating that that simple broadband continuum sources, although weak, are sufficient to create high quality 2D spectra with >200 nm bandwidth.

  7. In situ diagnosis of pulsed UV laser surface ablation of tungsten carbide hardmetal by using laser-induced optical emission spectroscopy

    NASA Astrophysics Data System (ADS)

    Li, Tiejun; Lou, Qihong; Wei, Yunrong; Huang, Feng; Dong, Jingxing; Liu, Jingru

    2001-12-01

    Surface ablation of cobalt cemented tungsten carbide hardmetal with pulsed UV laser has been in situ diagnosed by using the technique of laser-induced optical emission spectroscopy. The dependence of emission intensity of cobalt lines on number of laser shots was investigated at laser fluence of 2.5 J/cm 2. As a comparison, the reliance of emission intensity of cobalt lines as a function of laser pulse number by using pure cobalt as ablation sample was also studied at the same laser condition. It was found that for surface ablation of tungsten carbide hardmetal at laser fluence of 2.5 J/cm 2, the intensities of cobalt lines fell off dramatically in the first 300 consecutive laser shots and then slowed down to a low stable level with even more shots. For surface ablation of pure cobalt at the same laser condition, the intensities of cobalt lines remained constant more or less even after 500 laser shots and then reduced very slowly with even more shots. It was concluded that selective evaporation of cobalt at this laser fluence should be responsible for the dramatic fall-off of cobalt lines with laser shots accumulation for surface ablation of tungsten carbide hardmetal. In contrast, for surface ablation of pure cobalt, the slow reduction of cobalt lines with pulse number accumulation should be due to the formation of laser-induced crater effect.

  8. Considerations in high-resolution skeletal muscle diffusion tensor imaging using single-shot echo planar imaging with stimulated-echo preparation and sensitivity encoding.

    PubMed

    Karampinos, Dimitrios C; Banerjee, Suchandrima; King, Kevin F; Link, Thomas M; Majumdar, Sharmila

    2012-05-01

    Previous studies have shown that skeletal muscle diffusion tensor imaging (DTI) can noninvasively probe changes in the muscle fiber architecture and microstructure in diseased and damaged muscles. However, DTI fiber reconstruction in small muscles and in muscle regions close to aponeuroses and tendons remains challenging because of partial volume effects. Increasing the spatial resolution of skeletal muscle single-shot diffusion-weighted echo planar imaging (DW-EPI) can be hindered by the inherently low signal-to-noise ratio (SNR) of muscle DW-EPI because of the short muscle T(2) and the high sensitivity of single-shot EPI to off-resonance effects and T(2)* blurring. In this article, eddy current-compensated diffusion-weighted stimulated-echo preparation is combined with sensitivity encoding (SENSE) to maintain good SNR properties and to reduce the sensitivity to distortions and T(2)* blurring in high-resolution skeletal muscle single-shot DW-EPI. An analytical framework is developed to optimize the reduction factor and diffusion weighting time to achieve maximum SNR. Arguments for the selection of the experimental parameters are then presented considering the compromise between SNR, B(0)-induced distortions, T(2)* blurring effects and tissue incoherent motion effects. On the basis of the selected parameters in a high-resolution skeletal muscle single-shot DW-EPI protocol, imaging protocols at lower acquisition matrix sizes are defined with matched bandwidth in the phase-encoding direction and SNR. In  vivo results show that high-resolution skeletal muscle DTI with minimized sensitivity to geometric distortions and T(2)* blurring is feasible using the proposed methodology. In particular, a significant benefit is demonstrated from a reduction in partial volume effects for resolving multi-pennate muscles and muscles with small cross-sections in calf muscle DTI. Copyright © 2011 John Wiley & Sons, Ltd.

  9. Crystallography Without Crystals: Determining the Structure of Individual Biological Molecules and Nanoparticles

    ScienceCinema

    Ourmazd, Abbas [University of Wisconsin, Milwaukee, Wisconsin, USA

    2017-12-09

    Ever shattered a valuable vase into 10 to the 6th power pieces and tried to reassemble it under a light providing a mean photon count of 10 minus 2 per detector pixel with shot noise? If you can do that, you can do single-molecule crystallography. This talk will outline how this can be done in principle. In more technical terms, the talk will describe how the combination of scattering physics and Bayesian algorithms can be used to reconstruct the 3-D diffracted intensity distribution from a collection of individual 2-D diffiraction patterns down to a mean photon count of 10 minus 2 per pixel, the signal level anticipated from the Linac Coherent Light Source, and hence determine the structure of individual macromolecules and nanoparticles.

  10. Radiation Tolerance Characterization of Dual Band InAs/GaSb Type-II Strain-Layer Superlattice pBp Detectors Using 63 MeV Protons

    DTIC Science & Technology

    2012-01-01

    detectors . Using g and JD to also estimate the detec- tor sensitivity, expressed here in this letter by shot- noise - limited D*, is then done to...observed. To approximate the expected reduction in sensitivity with increasing UP, the shot- noise limited D* for the 45 lm detector was then calculated... noise limited D* (black squares) for 45 lm mesa detector with UP ranging from 0 to 3.75 1012 cm2 and post-anneal and with g (red circles) and JD

  11. Operation IVY, Pacific Proving Grounds, November 1952. Project 11.5. Radiobiological Studies at Eniwetok before and after Mike Shot

    DTIC Science & Technology

    1953-06-01

    by Species 4.3.3 Radiochemical Analysis 4.4 Invertebrates 4.4.1 Pretest . 4.4.2 Posttest . 15 16 16 18 19 19 19 19 20 20...with Highest Activity, Pretest 4.7 Frequencies of Invertebrate Ashed-sample Counts by Magnitudes, Pre- anc" Posttest .......... 4.8...JANET) BOGOMBOGO (BELLE) BOGALLUA (ALICE) 0 1 2 3 4 5 - PRETEST STATION • - POSTTEST STATION AOMON (SALLY) BIIJIRI (TILDA) ROJOA (URSULA

  12. HgCdTe APD-based linear-mode photon counting components and ladar receivers

    NASA Astrophysics Data System (ADS)

    Jack, Michael; Wehner, Justin; Edwards, John; Chapman, George; Hall, Donald N. B.; Jacobson, Shane M.

    2011-05-01

    Linear mode photon counting (LMPC) provides significant advantages in comparison with Geiger Mode (GM) Photon Counting including absence of after-pulsing, nanosecond pulse to pulse temporal resolution and robust operation in the present of high density obscurants or variable reflectivity objects. For this reason Raytheon has developed and previously reported on unique linear mode photon counting components and modules based on combining advanced APDs and advanced high gain circuits. By using HgCdTe APDs we enable Poisson number preserving photon counting. A metric of photon counting technology is dark count rate and detection probability. In this paper we report on a performance breakthrough resulting from improvement in design, process and readout operation enabling >10x reduction in dark counts rate to ~10,000 cps and >104x reduction in surface dark current enabling long 10 ms integration times. Our analysis of key dark current contributors suggest that substantial further reduction in DCR to ~ 1/sec or less can be achieved by optimizing wavelength, operating voltage and temperature.

  13. Recent results of PADReS, the Photon Analysis Delivery and REduction System, from the FERMI FEL commissioning and user operations.

    PubMed

    Zangrando, Marco; Cocco, Daniele; Fava, Claudio; Gerusina, Simone; Gobessi, Riccardo; Mahne, Nicola; Mazzucco, Eric; Raimondi, Lorenzo; Rumiz, Luca; Svetina, Cristian

    2015-05-01

    The Photon Analysis Delivery and REduction System of FERMI (PADReS) has been routinely used during the machine commissioning and operations of FERMI since 2011. It has also served the needs of several user runs at the facility from late 2012. The system is endowed with online and shot-to-shot diagnostics giving information about intensity, spatial-angular distribution, spectral content, as well as other diagnostics to determine coherence, pulse length etc. Moreover, PADReS is capable of manipulating the beam in terms of intensity and optical parameters. Regarding the optics, besides a standard refocusing system based on an ellipsoidal mirror, the Kirkpatrick-Baez active optics systems are key elements and have been used intensively to meet users' requirements. A general description of the system is given, together with some selected results from the commissioning/operations/user beam time.

  14. Evaluation of Surface Residual Stresses in Friction Stir Welds Due to Laser and Shot Peening

    NASA Technical Reports Server (NTRS)

    Hatamleh, Omar; Rivero, Iris V.; Lyons, Jed

    2007-01-01

    The effects of laser, and shot peening on the residual stresses in Friction Stir Welds (FSW) has been investigated. The surface residual stresses were measured at five different locations across the weld in order to produce an adequate residual stress profile. The residual stresses before and after sectioning the coupon from the welded plate were also measured, and the effect of coupon size on the residual stress relaxation was determined and characterized. Measurements indicate that residual stresses were not uniform along the welded plate, and large variation in stress magnitude could be exhibited at various locations along the FSW plate. Sectioning resulted in significant residual stress relaxation in the longitudinal direction attributed to the large change in dimensions in this direction. Overall, Laser and shot peening resulted in a significant reduction in tensile residual stresses at the surface of the specimens.

  15. Ground Squirrel Shooting and Potential Lead Exposure in Breeding Avian Scavengers

    PubMed Central

    Eagles-Smith, Collin A.; Wagner, Mason T.

    2016-01-01

    Recreational ground squirrel shooting is a popular activity throughout the western United States and serves as a tool for managing ground squirrel populations in agricultural regions. Belding’s ground squirrels (Spermophilus beldingi) are routinely shot in California, Nevada, and Oregon across habitats that overlap with breeding avian scavengers. Ground squirrels shot with lead (Pb)-based bullets may pose a risk to avian scavengers if they consume carcasses containing Pb fragments. To assess the potential risk to breeding avian scavengers we developed a model to estimate the number, mass, and distribution of Pb fragments in shot ground squirrels using radiographic images. Eighty percent of shot carcasses contained detectible Pb fragments with an average of 38.6 mg of Pb fragments. Seven percent of all carcasses contained Pb fragment masses exceeding a lethal dose for a model raptor nestling (e.g. American kestrel Falco sparverius). Bullet type did not influence the number of fragments in shot ground squirrels, but did influence the mass of fragments retained. Belding’s ground squirrels shot with .17 Super Mag and unknown ammunition types contained over 28 and 17 times more mass of Pb fragments than those shot with .22 solid and .22 hollow point bullets, respectively. Ground squirrel body mass was positively correlated with both the number and mass of Pb fragments in carcasses, increasing on average by 76% and 56% respectively across the range of carcass masses. Although the mass of Pb retained in ground squirrel carcasses was small relative to the original bullet mass, avian scavenger nestlings that frequently consume shot ground squirrels may be at risk for Pb-induced effects (e.g., physiology, growth, or survival). Using modeling efforts we found that if nestling golden eagles (Aquila chrysaetos), red-tailed hawks (Buteo jamaicensis), and Swainson’s hawks (B. swainsoni) consumed shot ground squirrels proportionately to the nestling’s mass, energy needs, and diet, 100% of the nestling period would exceed a 50% reduction in delta-aminolevulinic acid dehydratase production threshold, the last 13–27% of the nestling stage would exceed a reduced growth rate threshold, but no nestlings would be expected to exceed a level of Pb ingestion that would be lethal. PMID:27942006

  16. Ground squirrel shooting and potential lead exposure in breeding avian scavengers

    USGS Publications Warehouse

    Herring, Garth; Eagles-Smith, Collin A.; Wagner, Mason T.

    2016-01-01

    Recreational ground squirrel shooting is a popular activity throughout the western United States and serves as a tool for managing ground squirrel populations in agricultural regions. Belding’s ground squirrels (Spermophilus beldingi) are routinely shot in California, Nevada, and Oregon across habitats that overlap with breeding avian scavengers. Ground squirrels shot with lead (Pb)-based bullets may pose a risk to avian scavengers if they consume carcasses containing Pb fragments. To assess the potential risk to breeding avian scavengers we developed a model to estimate the number, mass, and distribution of Pb fragments in shot ground squirrels using radiographic images. Eighty percent of shot carcasses contained detectible Pb fragments with an average of 38.6 mg of Pb fragments. Seven percent of all carcasses contained Pb fragment masses exceeding a lethal dose for a model raptor nestling (e.g. American kestrel Falco sparverius). Bullet type did not influence the number of fragments in shot ground squirrels, but did influence the mass of fragments retained. Belding’s ground squirrels shot with .17 Super Mag and unknown ammunition types contained over 28 and 17 times more mass of Pb fragments than those shot with .22 solid and .22 hollow point bullets, respectively. Ground squirrel body mass was positively correlated with both the number and mass of Pb fragments in carcasses, increasing on average by 76% and 56% respectively across the range of carcass masses. Although the mass of Pb retained in ground squirrel carcasses was small relative to the original bullet mass, avian scavenger nestlings that frequently consume shot ground squirrels may be at risk for Pb-induced effects (e.g., physiology, growth, or survival). Using modeling efforts we found that if nestling golden eagles (Aquila chrysaetos), red-tailed hawks (Buteo jamaicensis), and Swainson’s hawks (B. swainsoni) consumed shot ground squirrels proportionately to the nestling’s mass, energy needs, and diet, 100% of the nestling period would exceed a 50% reduction in delta-aminolevulinic acid dehydratase production threshold, the last 13–27% of the nestling stage would exceed a reduced growth rate threshold, but no nestlings would be expected to exceed a level of Pb ingestion that would be lethal.

  17. Phase noise in pulsed Doppler lidar and limitations on achievable single-shot velocity accuracy

    NASA Technical Reports Server (NTRS)

    Mcnicholl, P.; Alejandro, S.

    1992-01-01

    The smaller sampling volumes afforded by Doppler lidars compared to radars allows for spatial resolutions at and below some sheer and turbulence wind structure scale sizes. This has brought new emphasis on achieving the optimum product of wind velocity and range resolutions. Several recent studies have considered the effects of amplitude noise, reduction algorithms, and possible hardware related signal artifacts on obtainable velocity accuracy. We discuss here the limitation on this accuracy resulting from the incoherent nature and finite temporal extent of backscatter from aerosols. For a lidar return from a hard (or slab) target, the phase of the intermediate frequency (IF) signal is random and the total return energy fluctuates from shot to shot due to speckle; however, the offset from the transmitted frequency is determinable with an accuracy subject only to instrumental effects and the signal to noise ratio (SNR), the noise being determined by the LO power in the shot noise limited regime. This is not the case for a return from a media extending over a range on the order of or greater than the spatial extent of the transmitted pulse, such as from atmospheric aerosols. In this case, the phase of the IF signal will exhibit a temporal random walk like behavior. It will be uncorrelated over times greater than the pulse duration as the transmitted pulse samples non-overlapping volumes of scattering centers. Frequency analysis of the IF signal in a window similar to the transmitted pulse envelope will therefore show shot-to-shot frequency deviations on the order of the inverse pulse duration reflecting the random phase rate variations. Like speckle, these deviations arise from the incoherent nature of the scattering process and diminish if the IF signal is averaged over times greater than a single range resolution cell (here the pulse duration). Apart from limiting the high SNR performance of a Doppler lidar, this shot-to-shot variance in velocity estimates has a practical impact on lidar design parameters. In high SNR operation, for example, a lidar's efficiency in obtaining mean wind measurements is determined by its repetition rate and not pulse energy or average power. In addition, this variance puts a practical limit on the shot-to-shot hard target performance required of a lidar.

  18. The FERMIatElettra FEL Photon Transport System

    NASA Astrophysics Data System (ADS)

    Zangrando, M.; Cudin, I.; Fava, C.; Godnig, R.; Kiskinova, M.; Masciovecchio, C.; Parmigiani, F.; Rumiz, L.; Svetina, C.; Turchet, A.; Cocco, D.

    2010-06-01

    The FERMI@Elettra free electron laser (FEL) user facility is under construction at Sincrotrone Trieste (Italy), and it will be operative in late 2010. It is based on a seeded scheme providing an almost perfect transform-limited and fully spatially coherent photon beam. FERMI@Elettra will cover the wavelength range 100 to 3 nm with the fundamental harmonics, and down to 1 nm with higher harmonics. We present the layout of the photon beam transport system that includes: the first common part providing on-line and shot-to-shot beam diagnostics, called PADReS (Photon Analysis Delivery and Reduction System), and 3 independent beamlines feeding the experimental stations. Particular emphasis is given to the solutions adopted to preserve the wavefront, and to avoid damage on the different optical elements. Peculiar FEL devices, not common in the Synchrotron Radiation facilities, are described in more detail, e.g. the online photon energy spectrometer measuring shot-by-shot the spectrum of the emitted radiation, the beam splitting and delay line system dedicated to cross/auto correlation and pump-probe experiments, and the wavefront preserving active optics adapting the shape and size of the focused spot to meet the needs of the different experiments.

  19. Writing time estimation of EB mask writer EBM-9000 for hp16nm/logic11nm node generation

    NASA Astrophysics Data System (ADS)

    Kamikubo, Takashi; Takekoshi, Hidekazu; Ogasawara, Munehiro; Yamada, Hirokazu; Hattori, Kiyoshi

    2014-10-01

    The scaling of semiconductor devices is slowing down because of the difficulty in establishing their functionality at the nano-size level and also because of the limitations in fabrications, mainly the delay of EUV lithography. While multigate devices (FinFET) are currently the main driver for scalability, other types of devices, such as 3D devices, are being realized to relax the scaling of the node. In lithography, double or multiple patterning using ArF immersion scanners is still a realistic solution offered for the hp16nm node fabrication. Other lithography candidates are those called NGL (Next Generation Lithography), such as DSA (Directed-Self-Assembling) or nanoimprint. In such situations, shot count for mask making by electron beam writers will not increase. Except for some layers, it is not increasing as previously predicted. On the other hand, there is another aspect that increases writing time. The exposure dose for mask writing is getting higher to meet tighter specifications of CD uniformity, in other words, reduce LER. To satisfy these requirements, a new electron beam mask writer, EBM-9000, has been developed for hp16nm/logic11nm generation. Electron optical system, which has the immersion lens system, was evolved from EBM-8000 to achieve higher current density of 800A/cm2. In this paper, recent shot count and dose trend are discussed. Also, writing time is estimated for the requirements in EBM-9000.

  20. Estimation of parameters in Shot-Noise-Driven Doubly Stochastic Poisson processes using the EM algorithm--modeling of pre- and postsynaptic spike trains.

    PubMed

    Mino, H

    2007-01-01

    To estimate the parameters, the impulse response (IR) functions of some linear time-invariant systems generating intensity processes, in Shot-Noise-Driven Doubly Stochastic Poisson Process (SND-DSPP) in which multivariate presynaptic spike trains and postsynaptic spike trains can be assumed to be modeled by the SND-DSPPs. An explicit formula for estimating the IR functions from observations of multivariate input processes of the linear systems and the corresponding counting process (output process) is derived utilizing the expectation maximization (EM) algorithm. The validity of the estimation formula was verified through Monte Carlo simulations in which two presynaptic spike trains and one postsynaptic spike train were assumed to be observable. The IR functions estimated on the basis of the proposed identification method were close to the true IR functions. The proposed method will play an important role in identifying the input-output relationship of pre- and postsynaptic neural spike trains in practical situations.

  1. Strong suppression of shot noise in a feedback-controlled single-electron transistor

    NASA Astrophysics Data System (ADS)

    Wagner, Timo; Strasberg, Philipp; Bayer, Johannes C.; Rugeramigabo, Eddy P.; Brandes, Tobias; Haug, Rolf J.

    2017-03-01

    Feedback control of quantum mechanical systems is rapidly attracting attention not only due to fundamental questions about quantum measurements, but also because of its novel applications in many fields in physics. Quantum control has been studied intensively in quantum optics but progress has recently been made in the control of solid-state qubits as well. In quantum transport only a few active and passive feedback experiments have been realized on the level of single electrons, although theoretical proposals exist. Here we demonstrate the suppression of shot noise in a single-electron transistor using an exclusively electronic closed-loop feedback to monitor and adjust the counting statistics. With increasing feedback response we observe a stronger suppression and faster freezing of charge current fluctuations. Our technique is analogous to the generation of squeezed light with in-loop photodetection as used in quantum optics. Sub-Poisson single-electron sources will pave the way for high-precision measurements in quantum transport similar to optical or optomechanical equivalents.

  2. High resolution light-sheet based high-throughput imaging cytometry system enables visualization of intra-cellular organelles

    NASA Astrophysics Data System (ADS)

    Regmi, Raju; Mohan, Kavya; Mondal, Partha Pratim

    2014-09-01

    Visualization of intracellular organelles is achieved using a newly developed high throughput imaging cytometry system. This system interrogates the microfluidic channel using a sheet of light rather than the existing point-based scanning techniques. The advantages of the developed system are many, including, single-shot scanning of specimens flowing through the microfluidic channel at flow rate ranging from micro- to nano- lit./min. Moreover, this opens-up in-vivo imaging of sub-cellular structures and simultaneous cell counting in an imaging cytometry system. We recorded a maximum count of 2400 cells/min at a flow-rate of 700 nl/min, and simultaneous visualization of fluorescently-labeled mitochondrial network in HeLa cells during flow. The developed imaging cytometry system may find immediate application in biotechnology, fluorescence microscopy and nano-medicine.

  3. Final Technical Progress Report: Development of Low-Cost Suspension Heliostat; December 7, 2011 - December 6, 2012

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bender, W.

    2013-01-01

    Final technical progress report of SunShot Incubator Solaflect Energy. The project succeeded in demonstrating that the Solaflect Suspension Heliostat design is viable for large-scale CSP installations. Canting accuracy is acceptable and is continually improving as Solaflect improves its understanding of this design. Cost reduction initiatives were successful, and there are still many opportunities for further development and further cost reduction.

  4. Effects of fusion relevant transient energetic radiation, plasma and thermal load on PLANSEE double forged tungsten samples in a low-energy plasma focus device

    NASA Astrophysics Data System (ADS)

    Javadi, S.; Ouyang, B.; Zhang, Z.; Ghoranneviss, M.; Salar Elahi, A.; Rawat, R. S.

    2018-06-01

    Tungsten is the leading candidate for plasma facing component (PFC) material for thermonuclear fusion reactors and various efforts are ongoing to evaluate its performance or response to intense fusion relevant radiation, plasma and thermal loads. This paper investigates the effects of hot dense decaying pinch plasma, highly energetic deuterium ions and fusion neutrons generated in a low-energy (3.0 kJ) plasma focus device on the structure, morphology and hardness of the PLANSEE double forged tungsten (W) samples surfaces. The tungsten samples were provided by Forschungszentrum Juelich (FZJ), Germany via International Atomic Energy Agency, Vienna, Austria. Tungsten samples were irradiated using different number of plasma focus (PF) shots (1, 5 and 10) at a fixed axial distance of 5 cm from the anode top and also at various distances from the top of the anode (5, 7, 9 and 11 cm) using fixed number (5) of plasma focus shots. The virgin tungsten sample had bcc structure (α-W phase). After PF irradiation, the XRD analysis showed (i) the presence of low intensity new diffraction peak corresponding to β-W phase at (211) crystalline plane indicating the partial structural phase transition in some of the samples, (ii) partial amorphization, and (iii) vacancy defects formation and compressive stress in irradiated tungsten samples. Field emission scanning electron microscopy showed the distinctive changes to non-uniform surface with nanometer sized particles and particle agglomerates along with large surface cracks at higher number of irradiation shots. X-ray photoelectron spectroscopy analysis demonstrated the reduction in relative tungsten oxide content and the increase in metallic tungsten after irradiation. Hardness of irradiated samples initially increased for one shot exposure due to reduction in tungsten oxide phase, but then decreased with increasing number of shots due to increasing concentration of defects. It is demonstrated that the plasma focus device provides appropriate intense fusion relevant pulses for testing the structural, morphological and mechanical changes on irradiated tungsten samples.

  5. Impact of blood products on platelet function in patients with traumatic injuries: a translational study.

    PubMed

    Henriksen, Hanne Hee; Grand, Alexandra G; Viggers, Sandra; Baer, Lisa A; Solbeck, Sacha; Cotton, Bryan A; Matijevic, Nena; Ostrowski, Sisse R; Stensballe, Jakob; Fox, Erin E; Chen, Tzu-An; Holcomb, John B; Johansson, Pär I; Cardenas, Jessica C; Wade, Charles E

    2017-06-15

    Reductions in platelet (PLT) count and function are associated with poor outcomes in trauma patients. We proposed to determine if patients expected to receive blood products have a decrease in PLT function higher than expected based on the reduction in PLT count, and if the reduction in function could be associated with the donor plasma/supernatant received. PLT count and function were measured on admission to the emergency department and intensive care unit in severely injured patients expected to receive a transfusion. PLT function was measured by Multiplate aggregometry in response to five agonists. Function was corrected for alterations in count. In vitro studies were conducted in the blood of normal subjects to assess the effect of dilutions with AB donor plasma on PLT function. Forty-six patients were enrolled, with 87% requiring a transfusion. Median Injury Severity Score was 23 (13, 29) and mortality 15%. PLT count and function were decreased from emergency department to intensive care unit admission by 25% and 58%, respectively. Decreases in function persisted after adjustment for count. Patients requiring large volumes of blood products had reductions in function that were disproportionately greater. Reductions in PLT function were greatest after transfusion of PLTs. In in vitro studies with a 30% dilution by autologous plasma caused a relational reduction in function, whereas allogenic plasma resulted in greater decreases that were highly variable between donors. Within hours of injury a decrease in both PLT count and function occurs, that is aggravated with the administration of blood products, with transfusion of PLTs showing the greatest effect. The effect on PLT function of allogenic transfused plasma appears to be highly donor related. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Characterizing isolated attosecond pulses with angular streaking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Siqi; Guo, Zhaoheng; Coffee, Ryan N.

    Here, we present a reconstruction algorithm for isolated attosecond pulses, which exploits the phase dependent energy modulation of a photoelectron ionized in the presence of a strong laser field. The energy modulation due to a circularly polarized laser field is manifest strongly in the angle-resolved photoelectron momentum distribution, allowing for complete reconstruction of the temporal and spectral profile of an attosecond burst. We show that this type of reconstruction algorithm is robust against counting noise and suitable for single-shot experiments. This algorithm holds potential for a variety of applications for attosecond pulse sources.

  7. Characterizing isolated attosecond pulses with angular streaking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Sigi; Guo, Zhaoheng; Coffee, Ryan N.

    We present a reconstruction algorithm for isolated attosecond pulses, which exploits the phase dependent energy modulation of a photoelectron ionized in the presence of a strong laser field. The energy modulation due to a circularly polarized laser field is manifest strongly in the angle-resolved photoelectron momentum distribution, allowing for complete reconstruction of the temporal and spectral profile of an attosecond burst. We show that this type of reconstruction algorithm is robust against counting noise and suitable for single-shot experiments. This algorithm holds potential for a variety of applications for attosecond pulse sources.

  8. Characterizing isolated attosecond pulses with angular streaking

    DOE PAGES

    Li, Siqi; Guo, Zhaoheng; Coffee, Ryan N.; ...

    2018-02-12

    Here, we present a reconstruction algorithm for isolated attosecond pulses, which exploits the phase dependent energy modulation of a photoelectron ionized in the presence of a strong laser field. The energy modulation due to a circularly polarized laser field is manifest strongly in the angle-resolved photoelectron momentum distribution, allowing for complete reconstruction of the temporal and spectral profile of an attosecond burst. We show that this type of reconstruction algorithm is robust against counting noise and suitable for single-shot experiments. This algorithm holds potential for a variety of applications for attosecond pulse sources.

  9. Characterizing isolated attosecond pulses with angular streaking

    DOE PAGES

    Li, Sigi; Guo, Zhaoheng; Coffee, Ryan N.; ...

    2018-02-13

    We present a reconstruction algorithm for isolated attosecond pulses, which exploits the phase dependent energy modulation of a photoelectron ionized in the presence of a strong laser field. The energy modulation due to a circularly polarized laser field is manifest strongly in the angle-resolved photoelectron momentum distribution, allowing for complete reconstruction of the temporal and spectral profile of an attosecond burst. We show that this type of reconstruction algorithm is robust against counting noise and suitable for single-shot experiments. This algorithm holds potential for a variety of applications for attosecond pulse sources.

  10. Non-Hardware ("Soft") Cost-Reduction Roadmap for Residential and Small Commercial Solar Photovoltaics, 2013-2020

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ardani, K.; Seif, D.; Margolis, R.

    2013-08-01

    The objective of this analysis is to roadmap the cost reductions and innovations necessary to achieve the U.S. Department of Energy (DOE) SunShot Initiative's total soft-cost targets by 2020. The roadmap focuses on advances in four soft-cost areas: (1) customer acquisition; (2) permitting, inspection, and interconnection (PII); (3) installation labor; and (4) financing. Financing cost reductions are in terms of the weighted average cost of capital (WACC) for financing PV system installations, with real-percent targets of 3.0% (residential) and 3.4% (commercial).

  11. Serious hazards of transfusion - conference report: celebration of 20 years of UK haemovigilance.

    PubMed

    Bolton-Maggs, P H B

    2017-12-01

    The Annual SHOT Report for incidents in 2016 was published on July 12 and celebrated of 20 years of UK haemovigilance. Components are very safe, related in part to risk-reduction measures triggered by SHOT reporting. Transfusion-related acute lung injury is now very rare (all plasma components are provided from male donors), and infection transmission is also uncommon - a single transmission of hepatitis E in 2016 and no bacterial transmissions. Human factors (errors) account for 87% of all reports. Deaths and major morbidity most often result from transfusion-associated circulatory overload. Wrong transfusions and deaths from ABO-incompatible transfusion can be reduced by correct bedside checks. It is notable that information technology systems may not be safe. Standardisation is required for flags and alerts. SHOT key recommendations include: assess patients for transfusion-associated circulatory overload prior to transfusion. Be like a pilot - use a bedside checklist when setting up the transfusion. © 2017 British Blood Transfusion Society.

  12. Acoustic-noise-optimized diffusion-weighted imaging.

    PubMed

    Ott, Martin; Blaimer, Martin; Grodzki, David M; Breuer, Felix A; Roesch, Julie; Dörfler, Arnd; Heismann, Björn; Jakob, Peter M

    2015-12-01

    This work was aimed at reducing acoustic noise in diffusion-weighted MR imaging (DWI) that might reach acoustic noise levels of over 100 dB(A) in clinical practice. A diffusion-weighted readout-segmented echo-planar imaging (EPI) sequence was optimized for acoustic noise by utilizing small readout segment widths to obtain low gradient slew rates and amplitudes instead of faster k-space coverage. In addition, all other gradients were optimized for low slew rates. Volunteer and patient imaging experiments were conducted to demonstrate the feasibility of the method. Acoustic noise measurements were performed and analyzed for four different DWI measurement protocols at 1.5T and 3T. An acoustic noise reduction of up to 20 dB(A) was achieved, which corresponds to a fourfold reduction in acoustic perception. The image quality was preserved at the level of a standard single-shot (ss)-EPI sequence, with a 27-54% increase in scan time. The diffusion-weighted imaging technique proposed in this study allowed a substantial reduction in the level of acoustic noise compared to standard single-shot diffusion-weighted EPI. This is expected to afford considerably more patient comfort, but a larger study would be necessary to fully characterize the subjective changes in patient experience.

  13. SunShot solar power reduces costs and uncertainty in future low-carbon electricity systems.

    PubMed

    Mileva, Ana; Nelson, James H; Johnston, Josiah; Kammen, Daniel M

    2013-08-20

    The United States Department of Energy's SunShot Initiative has set cost-reduction targets of $1/watt for central-station solar technologies. We use SWITCH, a high-resolution electricity system planning model, to study the implications of achieving these targets for technology deployment and electricity costs in western North America, focusing on scenarios limiting carbon emissions to 80% below 1990 levels by 2050. We find that achieving the SunShot target for solar photovoltaics would allow this technology to provide more than a third of electric power in the region, displacing natural gas in the medium term and reducing the need for nuclear and carbon capture and sequestration (CCS) technologies, which face technological and cost uncertainties, by 2050. We demonstrate that a diverse portfolio of technological options can help integrate high levels of solar generation successfully and cost-effectively. The deployment of GW-scale storage plays a central role in facilitating solar deployment and the availability of flexible loads could increase the solar penetration level further. In the scenarios investigated, achieving the SunShot target can substantially mitigate the cost of implementing a carbon cap, decreasing power costs by up to 14% and saving up to $20 billion ($2010) annually by 2050 relative to scenarios with Reference solar costs.

  14. Mechanism for atmosphere dependence of laser damage morphology in HfO2/SiO2 high reflective films

    NASA Astrophysics Data System (ADS)

    Pu, Yunti; Ma, Ping; Chen, Songlin; Zhu, Jiliang; Wang, Gang; Pan, Feng; Sun, Ping; Zhu, Xiaohong; Zhu, Jianguo; Xiao, Dingquan

    2012-07-01

    We show in this paper single-shot and multi-shot laser-induced damage thresholds (LIDTs) of HfO2/SiO2 high reflective films (the reflectance = 99.9%) are affected by the presence of a water layer absorbed on the surface of the porous films. When the water layer was removed with the process of pumping, the single-shot LIDT measured in vacuum dropped to ˜48% of that measured in air, while the multi-shot LIDT in vacuum dropped to ˜47% of its atmospheric value for the high reflective films. Typical damage micrographs of the films in air and in vacuum were obtained, showing distinct damage morphologies. Such atmosphere dependence of the laser damage morphology was found to originate from that formation of a water layer on the surface of porous films could cause an increase of horizontal thermal conductivity and a reduction of vertical thermal conductivity. Moreover, laser-induced periodic ripple damages in air were found in the SiO2 layer from the micrographs. A model of deformation kinematics was used to illustrate the occurrence of the periodic ripple damage, showing that it could be attributed to a contraction of the HfO2 layer under irradiation by the 5-ns laser pulses in air.

  15. Combining cluster number counts and galaxy clustering

    NASA Astrophysics Data System (ADS)

    Lacasa, Fabien; Rosenfeld, Rogerio

    2016-08-01

    The abundance of clusters and the clustering of galaxies are two of the important cosmological probes for current and future large scale surveys of galaxies, such as the Dark Energy Survey. In order to combine them one has to account for the fact that they are not independent quantities, since they probe the same density field. It is important to develop a good understanding of their correlation in order to extract parameter constraints. We present a detailed modelling of the joint covariance matrix between cluster number counts and the galaxy angular power spectrum. We employ the framework of the halo model complemented by a Halo Occupation Distribution model (HOD). We demonstrate the importance of accounting for non-Gaussianity to produce accurate covariance predictions. Indeed, we show that the non-Gaussian covariance becomes dominant at small scales, low redshifts or high cluster masses. We discuss in particular the case of the super-sample covariance (SSC), including the effects of galaxy shot-noise, halo second order bias and non-local bias. We demonstrate that the SSC obeys mathematical inequalities and positivity. Using the joint covariance matrix and a Fisher matrix methodology, we examine the prospects of combining these two probes to constrain cosmological and HOD parameters. We find that the combination indeed results in noticeably better constraints, with improvements of order 20% on cosmological parameters compared to the best single probe, and even greater improvement on HOD parameters, with reduction of error bars by a factor 1.4-4.8. This happens in particular because the cross-covariance introduces a synergy between the probes on small scales. We conclude that accounting for non-Gaussian effects is required for the joint analysis of these observables in galaxy surveys.

  16. Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T.

    PubMed

    Morelli, John; Porter, David; Ai, Fei; Gerdes, Clint; Saettele, Megan; Feiweier, Thorsten; Padua, Abraham; Dix, James; Marra, Michael; Rangaswamy, Rajesh; Runge, Val

    2013-04-01

    Diffusion-weighted imaging (DWI) magnetic resonance imaging (MRI) is most commonly performed utilizing a single-shot echo-planar imaging technique (ss-EPI). Susceptibility artifact and image blur are severe when this sequence is utilized at 3 T. To evaluate a readout-segmented approach to DWI MR in comparison with single-shot echo planar imaging for brain MRI. Eleven healthy volunteers and 14 patients with acute and early subacute infarctions underwent DWI MR examinations at 1.5 and 3T with ss-EPI and readout-segmented echo-planar (rs-EPI) DWI at equal nominal spatial resolutions. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) calculations were made, and two blinded readers ranked the scans in terms of high signal intensity bulk susceptibility artifact, spatial distortions, image blur, overall preference, and motion artifact. SNR and CNR were greatest with rs-EPI (8.1 ± 0.2 SNR vs. 6.0 ± 0.2; P <10(-4) at 3T). Spatial distortions were greater with single-shot (0.23 ± 0.03 at 3T; P <0.001) than with rs-EPI (0.12 ± 0.02 at 3T). Combined with blur and artifact reduction, this resulted in a qualitative preference for the readout-segmented scans overall. Substantial image quality improvements are possible with readout-segmented vs. single-shot EPI - the current clinical standard for DWI - regardless of field strength (1.5 or 3 T). This results in improved image quality secondary to greater real spatial resolution and reduced artifacts from susceptibility in MR imaging of the brain.

  17. On the Path to SunShot. The Environmental and Public Health Benefits of Achieving High Solar Penetrations in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiser, Ryan; Mai, Trieu; Millstein, Dev

    Compared with fossil fuel generators, photovoltaics (PV) and concentrating solar power (CSP) produce far lower lifecycle levels of greenhouse gas (GHG) emissions and harmful pollutants including fine particular matter (PM2.5), sulfur dioxide (SO 2), and nitrogen oxides (NO x). In this report, we monetize the emission reductions from achieving the U.S. Department of Energy's SunShot deployment goals: 14% of U.S. electricity demand met by solar in 2030 and 27% in 2050. We estimate that achieving these goals could reduce cumulative power-sector GHG emissions by 10% between 2015 and 2050, resulting in savings of $238-$252 billion. This is equivalent to 2.0-2.2more » cents per kilowatt-hour of solar installed (cents/kWh-solar). Similarly, realizing these levels of solar deployment could reduce cumulative power-sector emissions of PM2.5 by 8%, SO 2 by 9%, and NOx by 11% between 2015 and 2050. This could produce $167 billion in savings from lower future health and environmental damages, or 1.4 cents/kWh-solar--while also preventing 25,000-59,000 premature deaths. To put this in perspective, this estimated combined benefit of 3.5 cents/kWh-solar due to SunShot-level solar deployment is approximately equal to the additional levelized cost of electricity reduction needed to make unsubsidized utility-scale solar competitive with conventional generators today. In addition, the analysis shows that achieving the SunShot goals could save 4% of total power-sector water withdrawals and 9% of total power-sector water consumption over the 2015-2050 period--a particularly important consideration for arid states where substantial solar will be deployed. These results have potential implications for policy innovation and the economic competitiveness of solar and other generation technologies.« less

  18. Microstructural variation through weld thickness and mechanical properties of peened friction stir welded 6061 aluminum alloy joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdulstaar, Mustafa A., E-mail: mustafa.abdulstaar

    The current study examined the effect of microstructure variation on the development of mechanical properties in friction stir welded joints of 6061-T6 aluminum alloy, which were subsequently processed by shot peening (SP). Following to FSW, fatigue specimens were extracted perpendicularly to the welding direction. Surface Skimming to 0.5 mm from crown and root sides of the joint was made and SP was later applied on the two sides using ceramic shots of two different Almen intensities of 0.18 mmA and 0.24 mmA. Microstructural examination by electron back scattered diffraction (EBSD) indicated variation in the grain refinement of the weld zone,more » with coarsest grains (5 μm) at the crown side and finest grains (2 μm) at the root side. Reduction of microhardness to 60 HV occurred in the weld zone for samples in FSW condition. Application of SP promoted significant strain hardening at the crown side, with Almen intensities of 0.24 mmA providing maximum increase in microhardness to 120 HV. On the contrary, only a maximum microhardness of 75 HV was obtained at the root side. The difference in strain hardening capability at the two sides was strongly dependent on grain size. The two Almen intensities produced similar distribution of compressive residual stresses in the subsurface regions that led to enhance the fatigue strength to the level of base metal for N ≥ 10{sup 5} cycles. Yet, the increase in fatigue strength was more pronounced with increasing Almen intensity to 0.24 mmA, demonstrating further enhancement by strain hardening. - Highlights: • Grain refinement was observed after friction stir welding of AA 6061-T6. • Reduction in microhardness and fatigue strength were obtained after welding. • Variation in grain refinement led to different hardening behavior after peening. • Shot peening induced beneficial compressive residual stresses. • Shot peening and surface skimming markedly improved the fatigue performance.« less

  19. Dual crystal x-ray spectrometer at 1.8 keV for high repetition-rate single-photon counting spectroscopy experiments

    DOE PAGES

    Gamboa, E. J.; Bachmann, B.; Kraus, D.; ...

    2016-08-01

    The recent development of high-repetition rate x-ray free electron lasers (FEL), makes it possible to perform x-ray scattering and emission spectroscopy measurements from thin foils or gasses heated to high-energy density conditions by integrating over many experimental shots. Since the expected signal may be weaker than the typical CCD readout noise over the region-of-interest, it is critical to the success of this approach to use a detector with high-energy resolution so that single x-ray photons may be isolated. We describe a dual channel x-ray spectrometer developed for the Atomic and Molecular Optics endstation at the Linac Coherent Light Source (LCLS)more » for x-ray spectroscopy near the K-edge of aluminum. The spectrometer is based on a pair of curved PET (002) crystals coupled to a single pnCCD detector which simultaneously measures x-ray scattering and emission in the forward and backward directions. Furthermore, the signals from single x-ray photons are accumulated permitting continuous single-shot acquisition at 120 Hz.« less

  20. A molecular Rayleigh scattering setup to measure density fluctuations in thermal boundary layers

    NASA Astrophysics Data System (ADS)

    Panda, J.

    2016-12-01

    A Rayleigh scattering-based density fluctuation measurement system was set up inside a low-speed wind tunnel of NASA Ames Research Center. The immediate goal was to study the thermal boundary layer on a heated flat plate. A large number of obstacles had to be overcome to set up the system, such as the removal of dust particles using air filters, the use of photoelectron counting electronics to measure low intensity light, an optical layout to minimize stray light contamination, the reduction in tunnel vibration, and an expanded calibration process to relate photoelectron arrival rate to air density close to the plate surface. To measure spectra of turbulent density fluctuations, a two-PMT cross-correlation system was used to minimize the shot noise floor. To validate the Rayleigh measurements, temperature fluctuations spectra were calculated from density spectra and then compared with temperature spectra measured with a cold-wire probe operated in constant current mode. The spectra from the downstream half of the plate were found to be in good agreement with cold-wire probe, whereas spectra from the leading edge differed. Various lessons learnt are discussed. It is believed that the present effort is the first measurement of density fluctuations spectra in a boundary layer flow.

  1. A generalized quantitative interpretation of dark-field contrast for highly concentrated microsphere suspensions

    PubMed Central

    Gkoumas, Spyridon; Villanueva-Perez, Pablo; Wang, Zhentian; Romano, Lucia; Abis, Matteo; Stampanoni, Marco

    2016-01-01

    In X-ray grating interferometry, dark-field contrast arises due to partial extinction of the detected interference fringes. This is also called visibility reduction and is attributed to small-angle scattering from unresolved structures in the imaged object. In recent years, analytical quantitative frameworks of dark-field contrast have been developed for highly diluted monodisperse microsphere suspensions with maximum 6% volume fraction. These frameworks assume that scattering particles are separated by large enough distances, which make any interparticle scattering interference negligible. In this paper, we start from the small-angle scattering intensity equation and, by linking Fourier and real-space, we introduce the structure factor and thus extend the analytical and experimental quantitative interpretation of dark-field contrast, for a range of suspensions with volume fractions reaching 40%. The structure factor accounts for interparticle scattering interference. Without introducing any additional fitting parameters, we successfully predict the experimental values measured at the TOMCAT beamline, Swiss Light Source. Finally, we apply this theoretical framework to an experiment probing a range of system correlation lengths by acquiring dark-field images at different energies. This proposed method has the potential to be applied in single-shot-mode using a polychromatic X-ray tube setup and a single-photon-counting energy-resolving detector. PMID:27734931

  2. CD4 cell responses to combination antiretroviral therapy in patients starting therapy at high CD4 cell counts.

    PubMed

    Wright, Stephen T; Carr, Andrew; Woolley, Ian; Giles, Michelle; Hoy, Jennifer; Cooper, David A; Law, Matthew G

    2011-09-01

    To examine CD4 cell responses to combination antiretroviral therapy (cART) in patients enrolled in the Australian HIV Observational Database who commenced cART at CD4 cell counts >350 cells per microliter. CD4 cell counts were modelled using random effects, repeated measurement models in 432 HIV-infected adults from Australian HIV Observational Database who commenced their first cART regimen and had a baseline CD4 count >350 cells per microliter. Using published AIDS and/or death incidence rates combined with the data summarized by time and predicted CD4 cell count, we calculated the expected reduction in risk of an event for different starting baseline CD4 strata. Mean CD4 counts increased above 500 cells per microliter in all baseline CD4 strata by 12 months (means of 596, 717, and 881 cells/μL in baseline CD4 strata 351-500, 501-650, and >650 cells/μL, respectively) and after 72 months since initiating cART, mean CD4 cell counts (by increasing baseline CD4 strata) were 689, 746, 742 cells per microliter. The expected reduction in risk of mortality for baseline CD4 counts >650 cells per microliter relative to 351-500 cells per microliter was approximately 8%, an absolute risk reduction 0.33 per 1000 treated patient-years. Patients starting cART at high CD4 cell counts (>650 cells/μL) tend to maintain this immunological level over 6 years of follow-up. Patients starting from 351 to 500 CD4 cells per microliter achieve levels of >650 cells per microliter after approximately 3 years of cART. Initiating cART with a baseline CD4 count 501-650 or >650 cells per microliter relative to 351-500 cells per microliter indicated a minimal reduction in risk of AIDS incidence and/or death.

  3. PROPELLER for motion-robust imaging of in vivo mouse abdomen at 9.4 T.

    PubMed

    Teh, Irvin; Golay, Xavier; Larkman, David J

    2010-11-01

    In vivo high-field MRI in the abdomen of small animals is technically challenging because of the small voxel sizes, short T(2) and physiological motion. In standard Cartesian sampling, respiratory and gastrointestinal motion can lead to ghosting artefacts. Although respiratory triggering and navigator echoes can either avoid or compensate for motion, they can lead to variable TRs, require invasive intubation and ventilation, or extend TEs. A self-navigated fast spin echo (FSE)-based periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) acquisition was implemented at 9.4 T to enable high-resolution in vivo MRI of mouse abdomen without the use of additional navigators or triggering. T(2)-weighted FSE-PROPELLER data were compared with single-shot FSE and multi-shot FSE data with and without triggering. Single-shot methods, although rapid and robust to motion, demonstrated strong blurring. Multi-shot FSE data showed better resolution, but suffered from marked blurring in the phase-encoding direction and motion in between shots, leading to ghosting artefacts. When respiratory triggering was used, motion artefacts were largely avoided. However, TRs and acquisition times were lengthened by up to approximately 20%. The PROPELLER data showed a 25% and 61% improvement in signal-to-noise ratio and contrast-to-noise ratio, respectively, compared with multi-shot FSE data, together with a 35% reduction in artefact power. A qualitative comparison between acquisition methods using diffusion-weighted imaging was performed. The results were similar, with the exception that respiratory triggering was unable to exclude major motion artefacts as a result of the sensitisation to motion by the diffusion gradients. The PROPELLER data were of consistently higher quality. Considerations specific to the use of PROPELLER at high field are discussed, including the selection of practical blade widths and the effects on contrast, resolution and artefacts.

  4. Apparent Explosion Moments from Rg Waves Recorded on SPE: Implications for the Late-Time Damage Source Model

    NASA Astrophysics Data System (ADS)

    Patton, H. J.; Larmat, C. S.; Rougier, E.

    2016-12-01

    Seismic moments for chemical shots making up Phase I of the Source Physics Experiments (SPE) are estimated from 6 Hz Rg waves under the assumption that the shots are pure explosions. These apparent explosion moments are compared to moments determined using the Reduced Displacement Potential (RDP) method applied to free field data. LIDAR/photogrammetry observations, strong ground motions on the free surface near ground zero, and moment tensor inversion results are evidence in support of the fourth shot SPE-4P being essentially a pure explosion. The apparent moment for SPE-4P is 9 × 1010 Nm in good agreement with the RDP moment 8 × 1010 Nm. In stark contrast, apparent moments for the first three shots are three to four times smaller than RDP moments. Data show that spallation occurred on these shots, as well as permanent deformations detected with ground-based LIDAR. As such, the source medium suffered late-time damage. The late-time damage source model predicts destructive interference between Rg waves radiated by explosion and damage sources, which reduces amplitudes and explains why apparent moments are smaller than RDP moments based on compressional energy emitted directly from the source. SPE-5 was conducted at roughly the same yield-scaled burial depth as SPE-2 and -3, but with five times the yield. As such, the damage source model predicts less reduction of apparent moment. At this writing, preliminary results from Rg interferometry and RDP moments confirm this prediction. SPE-6 is scheduled for the fall of 2016, and it should have the strongest damage source of all SPE shots. The damage model predicts that the polarity of Rg waves could be reversed. Realization of this prediction will be strong confirmation of the late-time damage source model. This abstract has a Los Alamos National Laboratory Unlimited Release Number LA-UR-16-25709.

  5. Above scaling short-pulse ion acceleration from flat foil and ``Pizza-top Cone'' targets at the Trident laser facility

    NASA Astrophysics Data System (ADS)

    Flippo, Kirk; Hegelich, B. Manuel; Cort Gautier, D.; Johnson, J. Randy; Kline, John L.; Shimada, Tsutomu; Fernández, Juan C.; Gaillard, Sandrine; Rassuchine, Jennifer; Le Galloudec, Nathalie; Cowan, Thomas E.; Malekos, Steve; Korgan, Grant

    2006-10-01

    Ion-driven Fast Ignition (IFI) has certain advantages over electron-driven FI due to a possible large reduction in the amount of energy required. Recent experiments at the Los Alamos National Laboratory's Trident facility have yielded ion energies and efficiencies many times in excess of recent published scaling laws, leading to even more potential advantages of IFI. Proton energies in excess of 35 MeV have been observed from targets produced by the University of Nevada, Reno - dubbed ``Pizza-top Cone'' targets - at intensities of only 1x10^19 W/cm^2 with 20 joules in 600 fs. Energies in excess of 24 MeV were observed from simple flat foil targets as well. The observed energies, above any published scaling laws, are attributed to target production, preparation, and shot to shot monitoring of many laser parameters, especially the laser ASE prepulse level and laser pulse duration. The laser parameters are monitored in real-time to keep the laser in optimal condition throughout the run providing high quality, reproducible shots.

  6. Forward treatment planning techniques to reduce the normalization effect in Gamma Knife radiosurgery.

    PubMed

    Cheng, Hao-Wen; Lo, Wei-Lun; Kuo, Chun-Yuan; Su, Yu-Kai; Tsai, Jo-Ting; Lin, Jia-Wei; Wang, Yu-Jen; Pan, David Hung-Chi

    2017-11-01

    In Gamma Knife forward treatment planning, normalization effect may be observed when multiple shots are used for treating large lesions. This effect can reduce the proportion of coverage of high-value isodose lines within targets. The aim of this study was to evaluate the performance of forward treatment planning techniques using the Leksell Gamma Knife for the normalization effect reduction. We adjusted the shot positions and weightings to optimize the dose distribution and reduce the overlap of high-value isodose lines from each shot, thereby mitigating the normalization effect during treatment planning. The new collimation system, Leksell Gamma Knife Perfexion, which contains eight movable sectors, provides an additional means to reduce the normalization effect by using composite shots. We propose different techniques in forward treatment planning that can reduce the normalization effect. Reducing the normalization effect increases the coverage proportion of higher isodose lines within targets, making the high-dose region within targets more uniform and increasing the mean dose to targets. Because of the increase in the mean dose to the target after reducing the normalization effect, we can set the prescribed marginal dose at a higher isodose level and reduce the maximum dose, thereby lowering the risk of complications. © 2017 Shuang Ho Hospital-Taipei Medical University. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  7. On the Path to SunShot. The Role of Advancements in Solar Photovoltaic Efficiency, Reliability, and Costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodhouse, Michael; Jones-Albertus, Rebecca; Feldman, David

    2016-05-01

    This report examines the remaining challenges to achieving the competitive photovoltaic (PV) costs and large-scale deployment envisioned under the U.S. Department of Energy's SunShot Initiative. Solar-energy cost reductions can be realized through lower PV module and balance-of-system (BOS) costs as well as improved system efficiency and reliability. Numerous combinations of PV improvements could help achieve the levelized cost of electricity (LCOE) goals because of the tradeoffs among key metrics like module price, efficiency, and degradation rate as well as system price and lifetime. Using LCOE modeling based on bottom-up cost analysis, two specific pathways are mapped to exemplify the manymore » possible approaches to module cost reductions of 29%-38% between 2015 and 2020. BOS hardware and soft cost reductions, ranging from 54%-77% of total cost reductions, are also modeled. The residential sector's high supply-chain costs, labor requirements, and customer-acquisition costs give it the greatest BOS cost-reduction opportunities, followed by the commercial sector, although opportunities are available to the utility-scale sector as well. Finally, a future scenario is considered in which very high PV penetration requires additional costs to facilitate grid integration and increased power-system flexibility--which might necessitate even lower solar LCOEs. The analysis of a pathway to 3-5 cents/kWh PV systems underscores the importance of combining robust improvements in PV module and BOS costs as well as PV system efficiency and reliability if such aggressive long-term targets are to be achieved.« less

  8. Reduction of CMOS Image Sensor Read Noise to Enable Photon Counting.

    PubMed

    Guidash, Michael; Ma, Jiaju; Vogelsang, Thomas; Endsley, Jay

    2016-04-09

    Recent activity in photon counting CMOS image sensors (CIS) has been directed to reduction of read noise. Many approaches and methods have been reported. This work is focused on providing sub 1 e(-) read noise by design and operation of the binary and small signal readout of photon counting CIS. Compensation of transfer gate feed-through was used to provide substantially reduced CDS time and source follower (SF) bandwidth. SF read noise was reduced by a factor of 3 with this method. This method can be applied broadly to CIS devices to reduce the read noise for small signals to enable use as a photon counting sensor.

  9. Considerations in high resolution skeletal muscle DTI using single-shot EPI with stimulated echo preparation and SENSE

    PubMed Central

    Karampinos, Dimitrios C.; Banerjee, Suchandrima; King, Kevin F.; Link, Thomas M.; Majumdar, Sharmila

    2011-01-01

    Previous studies have shown that skeletal muscle diffusion tensor imaging (DTI) can non-invasively probe changes in the muscle fiber architecture and microstructure in diseased and damaged muscles. However, DTI fiber reconstruction in small muscles and in muscle regions close to aponeuroses and tendons remains challenging because of partial volume effects. Increasing the spatial resolution of skeletal muscle single-shot diffusion weighted (DW)-EPI can be hindered by the inherently low SNR of muscle DW-EPI due to the short muscle T2 and the high sensitivity of single-shot EPI to off-resonance effects and T2* blurring. In the present work, eddy-current compensated diffusion-weighted stimulated echo preparation is combined with sensitivity encoding (SENSE) to maintain good SNR properties and reduce the sensitivity to distortions and T2* blurring in high resolution skeletal muscle single-shot DW-EPI. An analytical framework is developed for optimizing the reduction factor and diffusion weighting time to achieve maximum SNR. Arguments for the selection of the experimental parameters are then presented considering the compromise between SNR, B0-induced distortions, T2* blurring effects and tissue incoherent motion effects. Based on the selected parameters in a high resolution skeletal muscle single-shot DW-EPI protocol, imaging protocols at lower acquisition matrix sizes are defined with matched bandwidth in the phase-encoding direction and SNR. In vivo results show that high resolution skeletal muscle DTI with minimized sensitivity to geometric distortions and T2* blurring is feasible using the proposed methodology. In particular, a significant benefit is demonstrated from reducing partial volume effects on resolving multi-pennate muscles and muscles with small cross sections in calf muscle DTI. PMID:22081519

  10. A comparison of methods used to obtain age ratios of snow and Canada geese

    USGS Publications Warehouse

    Higgins, K.F.; Linder, R.L.; Springer, P.F.

    1969-01-01

    The validity of group counts, cannon-net catches, and hunter-bag checks for estimating productivity of lesser snow geese (Anser caerulescens caerulescens) and small Canada geese (Branta canadensis hutchinsii-parvipes complex) was studied at Sand Lake National Wildlife Refuge during the falls of 1965 and 1966. Age ratios of snow geese obtained from net-trapped samples were significantly higher (P < 0.01) than from group counts at the same site. Immature snow geese were shot in a significantly greater (P < 0.01) proportion than they existed in the population as determined by group counts. Cannon-net catches and hunter-bag checks of snow and Canada geese yielded age ratios which were biased because of behavioral characteristics of the geese. Immatures of both species were less wary of trap equipment and immature snow geese were more vulnerable to the gun than adults. It was believed that age ratios from group counts of snow geese were more representative of the population than those from net catches and hunter-bag checks. Sex ratios of net-trapped geese showed a preponderance of males for adult Canada and adult and immature snow geese, whereas females were predominant in the immature segment of Canada geese. Hunter selectivity of blue- or white-phase snow geese was not observed at Sand Lake Refuge. Differential vulnerability to hunting between snow and Canada geese resulted from differences m feeding-flight behavior.

  11. Laser-induced bulk damage of silica glass at 355nm and 266nm

    NASA Astrophysics Data System (ADS)

    Kashiwagi, R.; Aramomi, S.

    2016-12-01

    Laser processing machines using Nd:YAG 3rd harmonic wave (355 nm) and 4th harmonic wave (266 nm) have been developed and put into practical use lately. Due to this, optical elements with high laser durability to 355 nm and 266 nm are required. Silica glass is the optical element which has high UV transmission and high laser durability. Laser-induced surface damage of the silica glass has been studied in detail, but we hardly have the significant knowledge of laserinduced bulk damage. This knowledge is required in order to evaluate the silica glass itself. That is because cracks and scratches on the surface give rise to a higher possibility of damage. Therefore, we studied the laser durability of a variety of the silica glass samples by 1-on-1 and S-on-1 laser-induced bulk damage threshold (LIDT) at 355 nm and 266 nm. In this study, we gained knowledge in three areas about bulk damage to the silica glass. First, the LIDT became lower as shot counts increased. Second, the LIDT decreased as the hydroxyl content in the silica glass increased. Last, the LIDT became higher as the hydrogen concentration in the silica glass increased. Under the UV irradiation, impurities are generated and the silica glass absorbs more light. Therefore, the LIDT decreased as shot counts increased. Also, the hydroxyl in particular generates more impurities, so damage easily occurs. On the other hand, the hydrogen reacts with impurities and absorption is suppressed. Based on these results, we can improve laser durability at 355 nm and 266 nm by reducing the hydroxyl content and increasing the hydrogen concentration in the silica glass.

  12. Increased Microerythrocyte Count in Homozygous α+-Thalassaemia Contributes to Protection against Severe Malarial Anaemia

    PubMed Central

    Fowkes, Freya J. I; Allen, Stephen J; Allen, Angela; Alpers, Michael P; Weatherall, David J; Day, Karen P

    2008-01-01

    Background The heritable haemoglobinopathy α+-thalassaemia is caused by the reduced synthesis of α-globin chains that form part of normal adult haemoglobin (Hb). Individuals homozygous for α+-thalassaemia have microcytosis and an increased erythrocyte count. α+-Thalassaemia homozygosity confers considerable protection against severe malaria, including severe malarial anaemia (SMA) (Hb concentration < 50 g/l), but does not influence parasite count. We tested the hypothesis that the erythrocyte indices associated with α+-thalassaemia homozygosity provide a haematological benefit during acute malaria. Methods and Findings Data from children living on the north coast of Papua New Guinea who had participated in a case-control study of the protection afforded by α+-thalassaemia against severe malaria were reanalysed to assess the genotype-specific reduction in erythrocyte count and Hb levels associated with acute malarial disease. We observed a reduction in median erythrocyte count of ∼1.5 × 1012/l in all children with acute falciparum malaria relative to values in community children (p < 0.001). We developed a simple mathematical model of the linear relationship between Hb concentration and erythrocyte count. This model predicted that children homozygous for α+-thalassaemia lose less Hb than children of normal genotype for a reduction in erythrocyte count of >1.1 × 1012/l as a result of the reduced mean cell Hb in homozygous α+-thalassaemia. In addition, children homozygous for α+-thalassaemia require a 10% greater reduction in erythrocyte count than children of normal genotype (p = 0.02) for Hb concentration to fall to 50 g/l, the cutoff for SMA. We estimated that the haematological profile in children homozygous for α+-thalassaemia reduces the risk of SMA during acute malaria compared to children of normal genotype (relative risk 0.52; 95% confidence interval [CI] 0.24–1.12, p = 0.09). Conclusions The increased erythrocyte count and microcytosis in children homozygous for α+-thalassaemia may contribute substantially to their protection against SMA. A lower concentration of Hb per erythrocyte and a larger population of erythrocytes may be a biologically advantageous strategy against the significant reduction in erythrocyte count that occurs during acute infection with the malaria parasite Plasmodium falciparum. This haematological profile may reduce the risk of anaemia by other Plasmodium species, as well as other causes of anaemia. Other host polymorphisms that induce an increased erythrocyte count and microcytosis may confer a similar advantage. PMID:18351796

  13. Use of hot water for beef carcass decontamination.

    PubMed

    Castillo, A; Lucia, L M; Goodson, K J; Savell, J W; Acuff, G R

    1998-01-01

    Hot water treatment of beef carcass surfaces for reduction of Escherichia coli O157:H7, Salmonella typhimurium, and various indicator organisms was studied using a model carcass spray cabinet. Paired hot carcass surface regions with different external fat characteristics (inside round, outside round, brisket, flank, and clod) were removed from carcasses immediately after the slaughter and dressing process. All cuts were inoculated with bovine feces containing 10(6)/g each of rifampicin-resistant E. coli O157:H7 and S. typhimurium, or with uninoculated bovine feces. Surfaces then were exposed to a carcass water wash or a water wash followed by hot water spray (95 degrees C). Counts of rifampicin-resistant Salmonella and E. coli or aerobic plate count (APC) and coliform counts were conducted before and after each treatment. All treatments significantly reduced levels of pathogens from the initial inoculation level of 5.0 log(10) CFU/cm2. Treatments including hot water sprays provided mean reductions of initial counts for E. coli O157:H7 and S. typhimurium of 3.7 and 3.8 log, APC reductions of 2.9 log, and coliform and thermotolerant coliform count reductions of 3.3 log. The efficacy of hot water treatments was affected by the carcass surface region, but not by delaying the treatment (30 min) after contaminating the surface. Verification of efficacy of hot water interventions used as critical control points in a hazard analysis critical control point (HACCP) system may be possible using coliform counts.

  14. Use of simulation tools to illustrate the effect of data management practices for low and negative plate counts on the estimated parameters of microbial reduction models.

    PubMed

    Garcés-Vega, Francisco; Marks, Bradley P

    2014-08-01

    In the last 20 years, the use of microbial reduction models has expanded significantly, including inactivation (linear and nonlinear), survival, and transfer models. However, a major constraint for model development is the impossibility to directly quantify the number of viable microorganisms below the limit of detection (LOD) for a given study. Different approaches have been used to manage this challenge, including ignoring negative plate counts, using statistical estimations, or applying data transformations. Our objective was to illustrate and quantify the effect of negative plate count data management approaches on parameter estimation for microbial reduction models. Because it is impossible to obtain accurate plate counts below the LOD, we performed simulated experiments to generate synthetic data for both log-linear and Weibull-type microbial reductions. We then applied five different, previously reported data management practices and fit log-linear and Weibull models to the resulting data. The results indicated a significant effect (α = 0.05) of the data management practices on the estimated model parameters and performance indicators. For example, when the negative plate counts were replaced by the LOD for log-linear data sets, the slope of the subsequent log-linear model was, on average, 22% smaller than for the original data, the resulting model underpredicted lethality by up to 2.0 log, and the Weibull model was erroneously selected as the most likely correct model for those data. The results demonstrate that it is important to explicitly report LODs and related data management protocols, which can significantly affect model results, interpretation, and utility. Ultimately, we recommend using only the positive plate counts to estimate model parameters for microbial reduction curves and avoiding any data value substitutions or transformations when managing negative plate counts to yield the most accurate model parameters.

  15. Babies and shots

    MedlinePlus

    ... MMR - shots; Pneumococcal - shots; Polio - shots; IPV - shots; Rotavirus - shots; Tdap - shots ... conjugate vaccine Pneumococcal polysaccharide vaccine Polio immunization (vaccine) Rotavirus vaccine Tdap vaccine

  16. Hybrid Tandem Solar Cells | Photovoltaic Research | NREL

    Science.gov Websites

    Hybrid Tandem Solar Cells Hybrid Tandem Solar Cells To achieve aggressive cost reductions in photovoltaics (PV) beyond the 6¢/kWh SunShot Initiative 2020 goal, module efficiency must be increased beyond on a silicon platform and that aim to provide viable prototypes for commercialization. PV Research

  17. Phase Noise Reduction of Laser Diode

    NASA Technical Reports Server (NTRS)

    Zhang, T. C.; Poizat, J.-Ph.; Grelu, P.; Roch, J.-F.; Grangier, P.; Marin, F.; Bramati, A.; Jost, V.; Levenson, M. D.; Giacobino, E.

    1996-01-01

    Phase noise of single mode laser diodes, either free-running or using line narrowing technique at room temperature, namely injection-locking, has been investigated. It is shown that free-running diodes exhibit very large excess phase noise, typically more than 80 dB above shot-noise at 10 MHz, which can be significantly reduced by the above-mentioned technique.

  18. Reduction of CMOS Image Sensor Read Noise to Enable Photon Counting

    PubMed Central

    Guidash, Michael; Ma, Jiaju; Vogelsang, Thomas; Endsley, Jay

    2016-01-01

    Recent activity in photon counting CMOS image sensors (CIS) has been directed to reduction of read noise. Many approaches and methods have been reported. This work is focused on providing sub 1 e− read noise by design and operation of the binary and small signal readout of photon counting CIS. Compensation of transfer gate feed-through was used to provide substantially reduced CDS time and source follower (SF) bandwidth. SF read noise was reduced by a factor of 3 with this method. This method can be applied broadly to CIS devices to reduce the read noise for small signals to enable use as a photon counting sensor. PMID:27070625

  19. The microbiological conditions of carcasses from large game animals in Italy.

    PubMed

    Avagnina, A; Nucera, D; Grassi, M A; Ferroglio, E; Dalmasso, A; Civera, T

    2012-07-01

    This study investigates the microbiological conditions of large game animal carcasses following evisceration. Carcasses of animals (N=291) hunted in the Upper Susa Valley (Italian Alps) were analysed for pH, Aerobic Viable Count (AVC), Enterobacteriaceae, Yersinia spp., Listeria monocytogenes and Salmonella spp. After shooting, evisceration occurred within 60 min in 90.7% of animals and sampling within 90 min in 88.3% of animals. Mean pH values (5.97: ruminants; 5.77: wild boar) were similar to those of regularly slaughtered domestic species. AVC values were highest in animals shot in the abdomen. Within species, AVC and Enterobacteriaceae values did not differ across different shooting-evisceration/sampling times. However, these counts exceeded 5 and 2.5 log, respectively, in 18% of wild boar and 39% of ruminants; the highest values were detected in wild boar. No pathogens were detected in any species. These results reveal inadequate hygiene in game meat handling/harvesting, implicating the need for improved practices. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Dressed tunneling approximation for electronic transport through molecular transistors

    NASA Astrophysics Data System (ADS)

    Seoane Souto, R.; Yeyati, A. Levy; Martín-Rodero, A.; Monreal, R. C.

    2014-02-01

    A theoretical approach for the nonequilibrium transport properties of nanoscale systems coupled to metallic electrodes with strong electron-phonon interactions is presented. It consists of a resummation of the dominant Feynman diagrams from the perturbative expansion in the coupling to the leads. We show that this scheme eliminates the main pathologies found in previous simple analytical approaches for the polaronic regime. The results for the spectral and transport properties are compared with those from several other approaches for a wide range of parameters. The method can be formulated in a simple way to obtain the full counting statistics. Results for the shot and thermal noise are presented.

  1. Reduction of Energy Intake using Just-In-Time Feedback from a Wearable Sensor System

    PubMed Central

    Farooq, Muhammad; McCrory, Megan A.; Sazonov, Edward

    2017-01-01

    Objective This work explored the potential use of a wearable sensor system for providing just-in-time (JIT) feedback on the progression of a meal and tested its ability to reduce the total food mass intake. Methods Eighteen participants each consumed three meals in a lab while monitored by a wearable sensor system capable of accurately tracking chew counts. The baseline visit was used to establish the self-determined ingested mass and the associated chew counts. Real-time feedback on chew counts was provided in the next two visits during which the target chew counts was either the same as that at baseline or the baseline chew counts reduced by 25%, in randomized order. The target was concealed from the participant and from the experimenter. Nonparametric repeated-measures ANOVA were performed to compare mass of intake, meal duration, and ratings of hunger, appetite, and thirst across 3 meals. Results JIT feedback targeting a 25% reduction in chew counts resulted in a reduction in mass and energy intake without affecting perceived hunger or fullness. Conclusion JIT feedback on chewing behavior may reduce intake within a meal. This system can be further used to help develop individualized strategies to provide just-in-time adaptive interventions for reducing energy intake. PMID:28233942

  2. Reduction of energy intake using just-in-time feedback from a wearable sensor system.

    PubMed

    Farooq, Muhammad; McCrory, Megan A; Sazonov, Edward

    2017-04-01

    This work explored the potential use of a wearable sensor system for providing just-in-time (JIT) feedback on the progression of a meal and tested its ability to reduce the total food mass intake. Eighteen participants consumed three meals each in a lab while monitored by a wearable sensor system capable of accurately tracking chew counts. The baseline visit was used to establish the self-determined ingested mass and the associated chew counts. Real-time feedback on chew counts was provided in the next two visits, during which the target chew count was either the same as that at baseline or the baseline chew count reduced by 25% (in randomized order). The target was concealed from the participant and from the experimenter. Nonparametric repeated-measures ANOVAs were performed to compare mass of intake, meal duration, and ratings of hunger, appetite, and thirst across three meals. JIT feedback targeting a 25% reduction in chew counts resulted in a reduction in mass and energy intake without affecting perceived hunger or fullness. JIT feedback on chewing behavior may reduce intake within a meal. This system can be further used to help develop individualized strategies to provide JIT adaptive interventions for reducing energy intake. © 2017 The Obesity Society.

  3. Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    PubMed

    Zhang, Zhiyong; Frydman, Lucio

    2018-03-01

    Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio penalties due to its non-Fourier nature and due to diffusion losses-especially when seeking high resolution. This study explores partial Fourier transform approaches that, acting along either the readout or the spatiotemporally encoded dimensions, reduce these penalties. xSPEN uses an orthogonal (e.g., z) gradient to read, in direct space, the low-bandwidth (e.g., y) dimension. This substantially changes the nature of partial Fourier acquisitions vis-à-vis conventional imaging counterparts. A suitable theoretical analysis is derived to implement these procedures, along either the spatiotemporally or readout axes. Partial Fourier single-shot xSPEN images were recorded on preclinical and human scanners. Owing to their reduction in the experiments' acquisition times, this approach provided substantial sensitivity gains vis-à-vis previous implementations for a given targeted in-plane resolution. The physical origins of these gains are explained. Partial Fourier approaches, particularly when implemented along the low-bandwidth spatiotemporal dimension, provide several-fold sensitivity advantages at minimal costs to the execution and processing of the single-shot experiments. Magn Reson Med 79:1506-1514, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  4. High-temperature fusion of a multielectron leviton

    NASA Astrophysics Data System (ADS)

    Moskalets, Michael

    2018-04-01

    The state of electrons injected onto the surface of the Fermi sea depends on temperature. The state is pure at zero temperature and is mixed at finite temperature. In the case of a single-electron injection, such a transformation can be detected as a decrease in shot noise with increasing temperature. In the case of a multielectron injection, the situation is subtler. The mixedness helps the development of quantum-mechanical exchange correlations between injected electrons, even if such correlations are absent at zero temperature. These correlations enhance the shot noise, which in part counteracts the reduction of noise with temperature. Moreover, at sufficiently high temperatures, the correlation contribution to noise predominates over the contribution of individual particles. As a result, in the system of N electrons, the apparent charge (which is revealed via the shot noise) is changed from e at zero temperature to N e at high temperatures. It looks like the exchange correlations glue electrons into one particle of total charge and energy. This point of view is supported by both charge noise and heat noise. Interestingly, in the macroscopic limit, N →∞ , the correlation contribution completely suppresses the effect of temperature on noise.

  5. The Uncertainty of Biomass Estimates from Modeled ICESat-2 Returns Across a Boreal Forest Gradient

    NASA Technical Reports Server (NTRS)

    Montesano, P. M.; Rosette, J.; Sun, G.; North, P.; Nelson, R. F.; Dubayah, R. O.; Ranson, K. J.; Kharuk, V.

    2014-01-01

    The Forest Light (FLIGHT) radiative transfer model was used to examine the uncertainty of vegetation structure measurements from NASA's planned ICESat-2 photon counting light detection and ranging (LiDAR) instrument across a synthetic Larix forest gradient in the taiga-tundra ecotone. The simulations demonstrate how measurements from the planned spaceborne mission, which differ from those of previous LiDAR systems, may perform across a boreal forest to non-forest structure gradient in globally important ecological region of northern Siberia. We used a modified version of FLIGHT to simulate the acquisition parameters of ICESat-2. Modeled returns were analyzed from collections of sequential footprints along LiDAR tracks (link-scales) of lengths ranging from 20 m-90 m. These link-scales traversed synthetic forest stands that were initialized with parameters drawn from field surveys in Siberian Larix forests. LiDAR returns from vegetation were compiled for 100 simulated LiDAR collections for each 10 Mg · ha(exp -1) interval in the 0-100 Mg · ha(exp -1) above-ground biomass density (AGB) forest gradient. Canopy height metrics were computed and AGB was inferred from empirical models. The root mean square error (RMSE) and RMSE uncertainty associated with the distribution of inferred AGB within each AGB interval across the gradient was examined. Simulation results of the bright daylight and low vegetation reflectivity conditions for collecting photon counting LiDAR with no topographic relief show that 1-2 photons are returned for 79%-88% of LiDAR shots. Signal photons account for approximately 67% of all LiDAR returns, while approximately 50% of shots result in 1 signal photon returned. The proportion of these signal photon returns do not differ significantly (p greater than 0.05) for AGB intervals greater than 20 Mg · ha(exp -1). The 50m link-scale approximates the finest horizontal resolution (length) at which photon counting LiDAR collection provides strong model fits and minimizes forest structure uncertainty in the synthetic Larix stands. At this link-scale AGB greater than 20 Mg · ha(exp -1) has AGB error from 20-50% at the 95% confidence level. These results suggest that the theoretical sensitivity of ICESat-2 photon counting LiDAR measurements alone lack the ability to consistently discern differences in inferred AGB at 10 Mg · ha(exp -1) intervals in sparse forests characteristic of the taiga-tundra ecotone.

  6. Correlation between pill counts and biologic effects in an HIV-1 prevention clinical trial: implications for measuring adherence.

    PubMed

    Donnell, Deborah J; Baeten, Jared M; Hong, Ting; Lingappa, Jairam R; Mujugira, Andrew; Nakku-Joloba, Edith; Bangsberg, David; Celum, Connie

    2013-02-01

    Clinic-based pill counts of unused study medication are frequently used to measure adherence in HIV-1 prevention trials. Monthly pill count adherence data from the Partners in Prevention HSV/HIV Transmission Study, a double-blind, placebo controlled trial of twice-daily acyclovir suppression of herpes simplex virus type 2 (HSV-2) in HIV-1 infected persons was used to compare changes between 3,381 placebo and active arm participants in two objective biologic measures of acyclovir's drug activity: reduction in plasma HIV-1 RNA and HSV-2 genital ulcer disease (GUD). Higher acyclovir pill count adherence was associated with greater reductions in plasma HIV-1 RNA and GUD, indicating pill count data is strongly correlated with biological effects of adherence. However, when calculated adherence exceeded 102 % (i.e., fewer pills returned than expected) and when pill counts were missing because bottles were not returned, plasma HIV-1 RNA and GUD effects were diminished, likely indicating periods of non-adherence.

  7. Recent results from the first polar direct drive plastic capsule implosions on NIF

    NASA Astrophysics Data System (ADS)

    Schmitt, Mark J.

    2012-10-01

    Polar direct drive (PDD) offers a simplified platform for conducting strongly driven implosions on NIF to investigate mix, hydro-burn and ignition-relevant physics. Its successful use necessitates a firm understanding and predictive capability of its implosion characteristics including hydro performance, symmetry and yield. To assess this capability, the first two PDD implosions of deuterium filled CH capsules were recently conducted at NIF. The P2 Legendre mode symmetry seen in these implosions agreed with pre-shot predictions even though the 700kJ drive energy produced intensities that far exceeded thresholds for both Raman and Brillouin stimulated scattering. These shots were also the first to employ image backlighting driven by two laser quads. Preliminary results indicate that the yield from the uncoated 2.25 mm diameter, 42 μm thick, CH shells was reduced by about a factor of two owing to as-shot laser drive asymmetries. Similarly, a small (sim50 μm) centroid offset between the upper and lower shell hemispheres seen in the first shot appears to be indicative of the laser quad energies. Overall, the implosion trajectories agreed with pre-shot predictions of bangtime. The second shot incorporated an 80 ?m wide,10 ?m deep depression encircling the equator of the capsule. This engineered feature was imposed to test our capability to predict the effect of high-mode features on yield and mix. A predicted yield reduction factor of 3 was not observed.[4pt] In collaboration with P. A. Bradley, J. A. Cobble, P. Hakel, S. C. Hsu, N. S. Krasheninnikova, G. A. Kyrala, G. R. Magelssen, T. J. Murphy, K. A. Obrey, R. C. Shah, I. L. Tregillis and F. J. Wysocki of Los Alamos National Laboratory; M. Marinak, R. Wallace, T. Parham, M. Cowan, S. Glenn, R. Benedetti and the NIF Operations Team of Lawrence Livermore National Laboratory; R. S. Craxton and P. W. McKenty of the Univ. Rochester; P. Fitzsimmons and A. Nikroo of General Atomics; H. Rinderknecht, M. Rosenberg, and M. G. Johnson, MIT; Work supported by US DOE/NNSA, performed at LANL, operated by LANS LLC under contract DE-AC52-06NA25396.

  8. Noise reduction of pneumatic nailers of up to 8 bar working pressure, considering handling properties and service life

    NASA Astrophysics Data System (ADS)

    Damberg, W.; Floegel, K.; Sahm, A.

    1983-02-01

    A noise reduction device for pneumatic nailers was developed. Conditions of use, range of products available, market regulations and measuring methods were studied. Ease of operation, service life, functional reliability and maintenance capacity were studied. Results show that the essential noise sources of the device are the compressed air blasts of the working and relation phases and the impact of the piston on the bumper. Packages of measures implemented on a laboratory scale indicate noise reduction possibilities for nailers in the short, medium and long term. The sound level of a single shot can be reduced from 110 dB to 93 dB.

  9. Alternative Hand Contamination Technique To Compare the Activities of Antimicrobial and Nonantimicrobial Soaps under Different Test Conditions▿

    PubMed Central

    Fuls, Janice L.; Rodgers, Nancy D.; Fischler, George E.; Howard, Jeanne M.; Patel, Monica; Weidner, Patrick L.; Duran, Melani H.

    2008-01-01

    Antimicrobial hand soaps provide a greater bacterial reduction than nonantimicrobial soaps. However, the link between greater bacterial reduction and a reduction of disease has not been definitively demonstrated. Confounding factors, such as compliance, soap volume, and wash time, may all influence the outcomes of studies. The aim of this work was to examine the effects of wash time and soap volume on the relative activities and the subsequent transfer of bacteria to inanimate objects for antimicrobial and nonantimicrobial soaps. Increasing the wash time from 15 to 30 seconds increased reduction of Shigella flexneri from 2.90 to 3.33 log10 counts (P = 0.086) for the antimicrobial soap, while nonantimicrobial soap achieved reductions of 1.72 and 1.67 log10 counts (P > 0.6). Increasing soap volume increased bacterial reductions for both the antimicrobial and the nonantimicrobial soaps. When the soap volume was normalized based on weight (∼3 g), nonantimicrobial soap reduced Serratia marcescens by 1.08 log10 counts, compared to the 3.83-log10 reduction caused by the antimicrobial soap (P < 0.001). The transfer of Escherichia coli to plastic balls following a 15-second hand wash with antimicrobial soap resulted in a bacterial recovery of 2.49 log10 counts, compared to the 4.22-log10 (P < 0.001) bacterial recovery on balls handled by hands washed with nonantimicrobial soap. This indicates that nonantimicrobial soap was less active and that the effectiveness of antimicrobial soaps can be improved with longer wash time and greater soap volume. The transfer of bacteria to objects was significantly reduced due to greater reduction in bacteria following the use of antimicrobial soap. PMID:18441107

  10. Alternative hand contamination technique to compare the activities of antimicrobial and nonantimicrobial soaps under different test conditions.

    PubMed

    Fuls, Janice L; Rodgers, Nancy D; Fischler, George E; Howard, Jeanne M; Patel, Monica; Weidner, Patrick L; Duran, Melani H

    2008-06-01

    Antimicrobial hand soaps provide a greater bacterial reduction than nonantimicrobial soaps. However, the link between greater bacterial reduction and a reduction of disease has not been definitively demonstrated. Confounding factors, such as compliance, soap volume, and wash time, may all influence the outcomes of studies. The aim of this work was to examine the effects of wash time and soap volume on the relative activities and the subsequent transfer of bacteria to inanimate objects for antimicrobial and nonantimicrobial soaps. Increasing the wash time from 15 to 30 seconds increased reduction of Shigella flexneri from 2.90 to 3.33 log(10) counts (P = 0.086) for the antimicrobial soap, while nonantimicrobial soap achieved reductions of 1.72 and 1.67 log(10) counts (P > 0.6). Increasing soap volume increased bacterial reductions for both the antimicrobial and the nonantimicrobial soaps. When the soap volume was normalized based on weight (approximately 3 g), nonantimicrobial soap reduced Serratia marcescens by 1.08 log(10) counts, compared to the 3.83-log(10) reduction caused by the antimicrobial soap (P < 0.001). The transfer of Escherichia coli to plastic balls following a 15-second hand wash with antimicrobial soap resulted in a bacterial recovery of 2.49 log(10) counts, compared to the 4.22-log(10) (P < 0.001) bacterial recovery on balls handled by hands washed with nonantimicrobial soap. This indicates that nonantimicrobial soap was less active and that the effectiveness of antimicrobial soaps can be improved with longer wash time and greater soap volume. The transfer of bacteria to objects was significantly reduced due to greater reduction in bacteria following the use of antimicrobial soap.

  11. Effect of Shot Peening in Different Shot Distance and Shot Angle on Surface Morphology, Surface Roughness and Surface Hardness of 316L Biomaterial

    NASA Astrophysics Data System (ADS)

    Umbu Kondi Maliwemu, Erich; Malau, Viktor; Iswanto, Priyo Tri

    2018-01-01

    Shot peening is a mechanical surface treatment with a beneficial effect to generate compressive residual stress caused by plastic deformation on the surface of material. This plastic deformation can improve the surface characteristics of metallic materials, such as modification of surface morphology, surface roughness, and surface hardness. The objective of this study is to investigate the effect of shot peening in different shot distance and shot angle on surface morphology, surface roughness, and surface hardness of 316L biomaterial. Shot distance was varied at 6, 8, 10, and 12 cm and shot angle at 30, 60, and 90°, working pressure at 7 kg/cm2, shot duration for 20 minutes, and using steel balls S-170 with diameter of 0.6 mm. The results present that the shot distance and shot angle of shot peening give the significant effect to improve the surface morphology, surface roughness, and surface hardness of 316 L biomaterial. Shot peening can increase the surface roughness by the increasing of shot distance and by the decreasing of shot angle. The nearest shot distance (6 cm) and the largest shot angle (90°) give the best results on the grain refinement with the surface roughness of 1.04 μm and surface hardness of 534 kg/mm2.

  12. Study on Plastic Deformation Characteristics of Shot Peening of Ni-Based Superalloy GH4079

    NASA Astrophysics Data System (ADS)

    Zhong, L. Q.; Liang, Y. L.; Hu, H.

    2017-09-01

    In this paper, the X-ray stress diffractometer, surface roughness tester, field emission scanning electron microscope(SEM), dynamic ultra-small microhardness tester were used to measure the surface residual stress and roughness, topography and surface hardness changes of GH4079 superalloy, which was processed by metallographic grinding, turning, metallographic grinding +shot peening and turning + shot peening. Analysized the effects of shot peening parameters on shot peening plastic deformation features; and the effects of the surface state before shot peening on shot peening plastic deformation characteristics. Results show that: the surface residual compressive stress, surface roughness and surface hardness of GH4079 superalloy were increased by shot peening, in addition, the increment of the surface residual compressive stress, surface roughness and surface hardness induced by shot peening increased with increasing shot peening intensity, shot peening time, shot peening pressure and shot hardness, but harden layer depth was not affected considerably. The more plastic deformation degree of before shot peening surface state, the less increment of the surface residual compressive stress, surface roughness and surface hardness induced by shot peening.

  13. Composite Aircraft Life Cycle Cost Estimating Model

    DTIC Science & Technology

    2011-03-01

    X. The masked fit of the lines are as follows: • Part Count Percentage Reduction for Design hours ( HRE %) = • Part Count Percentage Reduction...multiplied by the respective labor rate (LR). Currently, CT is a percentage of total non- recurring development cost. HRE corresponds to recurring...Empty Weight Velocity RENGR HRE CRE 46 Figure 14: Non-Recurring Engineering CER Currently, CT is a percentage of non-recurring development

  14. The efficacy of Mentha arvensis L. and M. piperita L. essential oils in reducing pathogenic bacteria and maintaining quality characteristics in cashew, guava, mango, and pineapple juices.

    PubMed

    de Sousa Guedes, Jossana Pereira; da Costa Medeiros, José Alberto; de Souza E Silva, Richard Sidney; de Sousa, Janaína Maria Batista; da Conceição, Maria Lúcia; de Souza, Evandro Leite

    2016-12-05

    This study evaluated the ability of the essential oil from Mentha arvensis L. (MAEO) and M. piperita L. (MPEO) to induce ≥5-log reductions in counts (CFU/mL) of E. coli, L. monocytogenes, and Salmonella enterica serovar Enteritidis in Brain-Heart Infusion broth (BHIB) and cashew, guava, mango, and pineapple juices during refrigerated storage (4±0.5°C). The effects of the incorporation of these essential oils on some physicochemical and sensory parameters of juices were also evaluated. The incorporation of 5, 2.5, 1.25, or 0.625μL/mL of MAEO in BHIB caused a ≥5-log reduction in counts of E. coli and Salmonella Enteritidis after 24h of storage; but only 5μL/mL was able to cause the same reduction in counts of L.monocytogenes. The incorporation of 10μL/mL of MPEO in BHIB caused a ≥5-log reduction in counts of E. coli, Salmonella Enteritidis, and L. monocytogenes after 24h of storage; smaller reductions were observed in BHIB containing 5, 2.5, and 1.25μL/mL of MPEO. Similar reductions were observed when the MAEO or MPEO was incorporated at the same concentrations in mango juice. The incorporation of MAEO or MPEO at all tested concentrations in cashew, guava, and pineapple juices resulted in a ≥5-log reduction in pathogen counts within 1h. The incorporation of MAEO and MPEO (0.625 and 1.25μL/mL, respectively) in fruit juices did not induce alterations in °Brix, pH, and acidity, but negatively affected the taste, aftertaste, and overall acceptance. The use of MAEO or MPEO at low concentrations could constitute an interesting tool to achieve the required 5-log reduction of pathogenic bacteria in cashew, guava, mango, and pineapple fruit juices. However, new methods combining the use of MAEO or MPEO with other technologies are necessary to reduce their negative impacts on specific sensory properties of these juices. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Graphene production by laser shot on graphene oxide: An ab initio prediction

    NASA Astrophysics Data System (ADS)

    Zhang, Hong; Miyamoto, Yoshiyuki

    2012-01-01

    By performing the first-principles simulation of electron-ion dynamics based on the time-dependent density-functional theory, we propose a way to produce graphene from graphene oxides by means of the laser-induced reduction without using chemical species. Epoxy and hydroxyl groups on graphene sheets can be completely removed upon irradiation with femtosecond laser without damaging the graphene sheet. By comparing the simulated results with different pulse shapes and intensities, optimum conditions of the femtosecond laser for reduction of graphene oxide were determined. The current works will be useful for further experimental researches.

  16. Progress in development of neutron energy spectrometer for deuterium plasma operation in KSTAR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tomita, H., E-mail: tomita@nagoya-u.jp; Yamashita, F.; Nakayama, Y.

    2014-11-15

    Two types of DD neutron energy spectrometer (NES) are under development for deuterium plasma operation in KSTAR to understand behavior of beam ions in the plasma. One is based on the state-of-the-art nuclear emulsion technique. The other is based on a coincidence detection of a recoiled proton and a scattered neutron caused by an elastic scattering of an incident DD neutron, which is called an associated particle coincidence counting-NES. The prototype NES systems were installed at J-port in KSTAR in 2012. During the 2012 and 2013 experimental campaigns, multiple shots-integrated neutron spectra were preliminarily obtained by the nuclear emulsion-based NESmore » system.« less

  17. Progress in development of neutron energy spectrometer for deuterium plasma operation in KSTARa)

    NASA Astrophysics Data System (ADS)

    Tomita, H.; Yamashita, F.; Nakayama, Y.; Morishima, K.; Yamamoto, Y.; Sakai, Y.; Cheon, M. S.; Isobe, M.; Ogawa, K.; Hayashi, S.; Kawarabayashi, J.; Iguchi, T.

    2014-11-01

    Two types of DD neutron energy spectrometer (NES) are under development for deuterium plasma operation in KSTAR to understand behavior of beam ions in the plasma. One is based on the state-of-the-art nuclear emulsion technique. The other is based on a coincidence detection of a recoiled proton and a scattered neutron caused by an elastic scattering of an incident DD neutron, which is called an associated particle coincidence counting-NES. The prototype NES systems were installed at J-port in KSTAR in 2012. During the 2012 and 2013 experimental campaigns, multiple shots-integrated neutron spectra were preliminarily obtained by the nuclear emulsion-based NES system.

  18. Single-electron thermal noise

    NASA Astrophysics Data System (ADS)

    Nishiguchi, Katsuhiko; Ono, Yukinori; Fujiwara, Akira

    2014-07-01

    We report the observation of thermal noise in the motion of single electrons in an ultimately small dynamic random access memory (DRAM). The nanometer-scale transistors that compose the DRAM resolve the thermal noise in single-electron motion. A complete set of fundamental tests conducted on this single-electron thermal noise shows that the noise perfectly follows all the aspects predicted by statistical mechanics, which include the occupation probability, the law of equipartition, a detailed balance, and the law of kT/C. In addition, the counting statistics on the directional motion (i.e., the current) of the single-electron thermal noise indicate that the individual electron motion follows the Poisson process, as it does in shot noise.

  19. Single-electron thermal noise.

    PubMed

    Nishiguchi, Katsuhiko; Ono, Yukinori; Fujiwara, Akira

    2014-07-11

    We report the observation of thermal noise in the motion of single electrons in an ultimately small dynamic random access memory (DRAM). The nanometer-scale transistors that compose the DRAM resolve the thermal noise in single-electron motion. A complete set of fundamental tests conducted on this single-electron thermal noise shows that the noise perfectly follows all the aspects predicted by statistical mechanics, which include the occupation probability, the law of equipartition, a detailed balance, and the law of kT/C. In addition, the counting statistics on the directional motion (i.e., the current) of the single-electron thermal noise indicate that the individual electron motion follows the Poisson process, as it does in shot noise.

  20. Assessment of the effect of probiotic curd consumption on salivary pH and streptococcus mutans counts.

    PubMed

    Sudhir, R; Praveen, P; Anantharaj, A; Venkataraghavan, Karthik

    2012-07-01

    Antimicrobial methods of controlling dental caries that include probiotic agents can play a valuable role in establishing caries control in children at moderate to high risk for developing dental caries. Several studies have demonstrated the beneficial effects of use of various Probiotic products including curd. The objective of this study was to compare the effect of short-term consumption of probiotic curd containing Lactobacillus acidophilus and normal curd on salivary Streptococcus Mutans counts, as well as salivary pH. Forty, caries-free, 10-12 years old children were selected and randomly allocated to two groups. Test Group consisted of 20 children who consumed 200ml of probiotic curd daily for 30 days. Control Group consisted of 20 children who were given 200ml of regular curd for 30 days. Salivary pH and salivary Streptococcus Mutans counts were recorded at baseline and after 30 days and statistically compared using the Student's t-test. Consumption of probiotic curd resulted in a statistically significant reduction in S. Mutans colony counts (P<0.001) as compared to regular curd. However, there was a slight reduction in pH (P>0.05) in both the groups. Short-term consumption of probiotic curds can reduce oral S. Mutans counts. However, this caused a slight reduction in salivary pH.

  1. FY14 LLNL OMEGA Experimental Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heeter, R. F.; Fournier, K. B.; Baker, K.

    In FY14, LLNL’s High-Energy-Density Physics (HED) and Indirect Drive Inertial Confinement Fusion (ICF-ID) programs conducted several campaigns on the OMEGA laser system and on the EP laser system, as well as campaigns that used the OMEGA and EP beams jointly. Overall these LLNL programs led 324 target shots in FY14, with 246 shots using just the OMEGA laser system, 62 shots using just the EP laser system, and 16 Joint shots using Omega and EP together. Approximately 31% of the total number of shots (62 OMEGA shots, 42 EP shots) shots supported the Indirect Drive Inertial Confinement Fusion Campaign (ICF-ID).more » The remaining 69% (200 OMEGA shots and 36 EP shots, including the 16 Joint shots) were dedicated to experiments for High- Energy-Density Physics (HED). Highlights of the various HED and ICF campaigns are summarized in the following reports.« less

  2. Single-shot measurement of >1010 pulse contrast for ultra-high peak-power lasers

    NASA Astrophysics Data System (ADS)

    Wang, Yongzhi; Ma, Jingui; Wang, Jing; Yuan, Peng; Xie, Guoqiang; Ge, Xulei; Liu, Feng; Yuan, Xiaohui; Zhu, Heyuan; Qian, Liejia

    2014-01-01

    Real-time pulse-contrast observation with a high dynamic range is a prerequisite to tackle the contrast challenge in ultra-high peak-power lasers. However, the commonly used delay-scanning cross-correlator (DSCC) can only provide the time-consumed measurements for repetitive lasers. Single-shot cross-correlator (SSCC) becomes essential in optimizing laser systems and exploring contrast mechanisms. Here we report our progress in developing SSCC towards its practical use. By integrating both the techniques of scattering-noise reduction and sensitive parallel detection into SSCC, we demonstrate a high dynamic range of >1010, which, to our best knowledge, is the first demonstration of an SSCC with a dynamic range comparable to that of commercial DSCCs. The comparison of high-dynamic measurement performances between SSCC and a standard DSCC (Sequoia, Amplitude Technologies) is also carried out on a 200 TW Ti:sapphire laser, and the consistency of results verifies the veracity of our SSCC.

  3. Spectral properties of thermal fluctuations on simple liquid surfaces below shot-noise levels.

    PubMed

    Aoki, Kenichiro; Mitsui, Takahisa

    2012-07-01

    We study the spectral properties of thermal fluctuations on simple liquid surfaces, sometimes called ripplons. Analytical properties of the spectral function are investigated and are shown to be composed of regions with simple analytic behavior with respect to the frequency or the wave number. The derived expressions are compared to spectral measurements performed orders of magnitude below shot-noise levels, which is achieved using a novel noise reduction method. The agreement between the theory of thermal surface fluctuations and the experiment is found to be excellent, elucidating the spectral properties of the surface fluctuations. The measurement method requires relatively only a small sample both spatially (few μm) and temporally (~20 s). The method also requires relatively weak light power (~0.5 mW) so that it has a broad range of applicability, including local measurements, investigations of time-dependent phenomena, and noninvasive measurements.

  4. Invited Article: Single-shot THz detection techniques optimized for multidimensional THz spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teo, Stephanie M.; Ofori-Okai, Benjamin K.; Werley, Christopher A.

    Multidimensional spectroscopy at visible and infrared frequencies has opened a window into the transfer of energy and quantum coherences at ultrafast time scales. For these measurements to be performed in a manageable amount of time, one spectral axis is typically recorded in a single laser shot. An analogous rapid-scanning capability for THz measurements will unlock the multidimensional toolkit in this frequency range. Here, we first review the merits of existing single-shot THz schemes and discuss their potential in multidimensional THz spectroscopy. We then introduce improved experimental designs and noise suppression techniques for the two most promising methods: frequency-to-time encoding withmore » linear spectral interferometry and angle-to-time encoding with dual echelons. Both methods, each using electro-optic detection in the linear regime, were able to reproduce the THz temporal waveform acquired with a traditional scanning delay line. Although spectral interferometry had mediocre performance in terms of signal-to-noise, the dual echelon method was easily implemented and achieved the same level of signal-to-noise as the scanning delay line in only 4.5% of the laser pulses otherwise required (or 22 times faster). This reduction in acquisition time will compress day-long scans to hours and hence provides a practical technique for multidimensional THz measurements.« less

  5. Invited Article: Single-shot THz detection techniques optimized for multidimensional THz spectroscopy.

    PubMed

    Teo, Stephanie M; Ofori-Okai, Benjamin K; Werley, Christopher A; Nelson, Keith A

    2015-05-01

    Multidimensional spectroscopy at visible and infrared frequencies has opened a window into the transfer of energy and quantum coherences at ultrafast time scales. For these measurements to be performed in a manageable amount of time, one spectral axis is typically recorded in a single laser shot. An analogous rapid-scanning capability for THz measurements will unlock the multidimensional toolkit in this frequency range. Here, we first review the merits of existing single-shot THz schemes and discuss their potential in multidimensional THz spectroscopy. We then introduce improved experimental designs and noise suppression techniques for the two most promising methods: frequency-to-time encoding with linear spectral interferometry and angle-to-time encoding with dual echelons. Both methods, each using electro-optic detection in the linear regime, were able to reproduce the THz temporal waveform acquired with a traditional scanning delay line. Although spectral interferometry had mediocre performance in terms of signal-to-noise, the dual echelon method was easily implemented and achieved the same level of signal-to-noise as the scanning delay line in only 4.5% of the laser pulses otherwise required (or 22 times faster). This reduction in acquisition time will compress day-long scans to hours and hence provides a practical technique for multidimensional THz measurements.

  6. Aqueous extract of yellow maca (Lepidium meyenii) improves sperm count in experimental animals but response depends on hypocotyl size, pH and routes of administration.

    PubMed

    Sanchez-Salazar, L; Gonzales, G F

    2018-04-01

    Lepidium meyenii, a Peruvian plant growing over 4000 m.a.s.l., has effects on nutrition and fertility. The purpose of this study was to evaluate the sperm count in 105 male mice receiving boiled aqueous extract of yellow maca hypocotyls from different sizes, under different pH conditions and using two different routes of administration. Five mice per group were treated daily for 3 days with vehicle (oral and intraperitoneal) or maca aqueous extracts (5 mg/0.5 ml/day) belonging to the first, second, third and fourth categories, according to their hypocotyl size. On day four, sperm count was evaluated at testis, epididymis and vas deferens. Sperm count was higher in mice receiving maca from the larger sizes (first and second categories). Reduction in maca extract pH increased sperm count, whereas an increase in the pH resulted in a reduction in sperm count. The effect of pH reduction is observed only in maca from the first and second categories. Aqueous extract of maca was effective only after oral administration. In conclusion, the larger size of hypocotyls presented the best biological effect, and the low pH in the extract and the transformation after gastrointestinal passage are both important for its biological action. © 2017 Blackwell Verlag GmbH.

  7. 50 CFR 20.134 - Approval of nontoxic shot types and shot coatings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... erosion and absorption of one shot or coated shot in a 24-hour period. Define the nature of the toxic...) with one U.S. No. 4 pellet of lead shot. Dose each bird in one group of 8 males and 8 females with 8 U... males and 8 females with one U.S. No. 4 pellet of the candidate shot type or shot with the proposed...

  8. Noise characterization of a 512×16 spad line sensor for time-resolved spectroscopy applications

    NASA Astrophysics Data System (ADS)

    Finlayson, Neil; Usai, Andrea; Erdogan, Ahmet T.; Henderson, Robert K.

    2018-02-01

    Time-resolved spectroscopy in the presence of noise is challenging. We have developed a new 512 pixel line sensor with 16 single-photon-avalanche (SPAD) detectors per pixel and ultrafast in-pixel time-correlated single photon counting (TCSPC) histogramming for such applications. SPADs are near shot noise limited detectors but we are still faced with the problem of high dark count rate (DCR) SPADs. The noisiest SPADs can be switched off to optimise signal-to-noiseratios (SNR) at the expense of longer acquisition/exposure times than would be possible if more SPADs were exploited. Here we present detailed noise characterization of our array. We build a DCR map for the sensor and demonstrate the effect of switching off the noisiest SPADs in each pixel. 24% percent of SPADs in the array are measured to have DCR in excess of 1kHz, while the best SPAD selection per pixel reduces DCR to 53+/-7Hz across the entire array. We demonstrate that selection of the lowest DCR SPAD in each pixel leads to the emergence of sparse spatial sampling noise in the sensor.

  9. Robotics

    NASA Technical Reports Server (NTRS)

    Rothschild, Lynn J.

    2012-01-01

    Earth's upper atmosphere is an extreme environment: dry, cold, and irradiated. It is unknown whether our aerobiosphere is limited to the transport of life, or there exist organisms that grow and reproduce while airborne (aerophiles); the microenvironments of suspended particles may harbor life at otherwise uninhabited altitudes[2]. The existence of aerophiles would significantly expand the range of planets considered candidates for life by, for example, including the cooler clouds of a hot Venus-like planet. The X project is an effort to engineer a robotic exploration and biosampling payload for a comprehensive survey of Earth's aerobiology. While many one-shot samples have been retrieved from above 15 km, their results are primarily qualitative; variations in method confound comparisons, leaving such major gaps in our knowledge of aerobiology as quantification of populations at different strata and relative species counts[1]. These challenges and X's preliminary solutions are explicated below. X's primary balloon payload is undergoing a series of calibrations before beginning flights in Spring 2012. A suborbital launch is currently planned for Summer 2012. A series of ground samples taken in Winter 2011 is being used to establish baseline counts and identify likely background contaminants.

  10. A simulator for airborne laser swath mapping via photon counting

    NASA Astrophysics Data System (ADS)

    Slatton, K. C.; Carter, W. E.; Shrestha, R.

    2005-06-01

    Commercially marketed airborne laser swath mapping (ALSM) instruments currently use laser rangers with sufficient energy per pulse to work with return signals of thousands of photons per shot. The resulting high signal to noise level virtually eliminates spurious range values caused by noise, such as background solar radiation and sensor thermal noise. However, the high signal level approach requires laser repetition rates of hundreds of thousands of pulses per second to obtain contiguous coverage of the terrain at sub-meter spatial resolution, and with currently available technology, affords little scalability for significantly downsizing the hardware, or reducing the costs. A photon-counting ALSM sensor has been designed by the University of Florida and Sigma Space, Inc. for improved topographic mapping with lower power requirements and weight than traditional ALSM sensors. Major elements of the sensor design are presented along with preliminary simulation results. The simulator is being developed so that data phenomenology and target detection potential can be investigated before the system is completed. Early simulations suggest that precise estimates of terrain elevation and target detection will be possible with the sensor design.

  11. The variable and chaotic nature of professional golf performance.

    PubMed

    Stöckl, Michael; Lamb, Peter F

    2018-05-01

    In golf, unlike most other sports, individual performance is not the result of direct interactions between players. Instead decision-making and performance is influenced by numerous constraining factors affecting each shot. This study looked at the performance of PGA TOUR golfers in 2011 in terms of stability and variability on a shot-by-shot basis. Stability and variability were assessed using Recurrence Quantification Analysis (RQA) and standard deviation, respectively. About 10% of all shots comprised short stable phases of performance (3.7 ± 1.1 shots per stable phase). Stable phases tended to consist of shots of typical performance, rather than poor or exceptional shots; this finding was consistent for all shot categories. Overall, stability measures were not correlated with tournament performance. Variability across all shots was not related to tournament performance; however, variability in tee shots and short approach shots was higher than for other shot categories. Furthermore, tee shot variability was related to tournament standing: decreased variability was associated with better tournament ranking. The findings in this study showed that PGA TOUR golf performance is chaotic. Further research on amateur golf performance is required to determine whether the structure of amateur golf performance is universal.

  12. Shot model parameters for Cygnus X-1 through phase portrait fitting

    NASA Technical Reports Server (NTRS)

    Lochner, James C.; Swank, J. H.; Szymkowiak, A. E.

    1991-01-01

    Shot models for systems having about 1/f power density spectrum are developed by utilizing a distribution of shot durations. Parameters of the distribution are determined by fitting the power spectrum either with analytic forms for the spectrum of a shot model with a given shot profile, or with the spectrum derived from numerical realizations of trial shot models. The shot fraction is specified by fitting the phase portrait, which is a plot of intensity at a given time versus intensity at a delayed time and in principle is sensitive to different shot profiles. These techniques have been extensively applied to the X-ray variability of Cygnus X-1, using HEAO 1 A-2 and an Exosat ME observation. The power spectra suggest models having characteristic shot durations lasting from milliseconds to a few seconds, while the phase portrait fits give shot fractions of about 50 percent. Best fits to the portraits are obtained if the amplitude of the shot is a power-law function of the duration of the shot. These fits prefer shots having a symmetric exponential rise and decay. Results are interpreted in terms of a distribution of magnetic flares in the accretion disk.

  13. Combined action of nisin and carvacrol on Bacillus cereus and Listeria monocytogenes.

    PubMed

    Pol, I E; Smid, E J

    1999-09-01

    Nisin, a small antimicrobial protein, was tested for its bactericidal action against Listeria monocytogenes and Bacillus cereus and a typical biphasic reduction of the viable count was observed. The reduction was most fast during the first 10 min of exposure, while the viable count remained stable in the last part of the exposure period. Bacillus cereus was more sensitive towards nisin than L. monocytogenes and the inhibitory effect of nisin was stronger towards cells cultivated and exposed at 8 degrees C than towards cells cultivated and exposed at 20 degrees C. Combining nisin with sublethal doses of carvacrol resulted in an increased reduction in the viable count of both organisms, indicating synergy between nisin and carvacrol. Addition of lysozyme as a third preservative factor increased the synergistic effect between nisin and carvone, especially in the last part of the exposure period.

  14. The efficacy of a combined oral formulation of derquantel-abamectin against anthelmintic resistant gastro-intestinal nematodes of sheep in the UK.

    PubMed

    Geurden, Thomas; Hodge, Andrew; Noé, Laura; Winstanley, Dana; Bartley, David J; Taylor, Mike; Morgan, Colin; Fraser, Sarah J; Maeder, Steven; Bartram, David

    2012-10-26

    The objective of the present studies was to evaluate the efficacy of a combined formulation (Startect(®) Dual Active Oral Solution for Sheep, Pfizer Animal Health) of derquantel (DQL) and abamectin (ABA) for the treatment of: (1) sheep experimentally infected with a moxidectin (MOX)-resistant isolate of Teladorsagia circumcincta, and (2) multi-drug resistant gastrointestinal nematode parasites under UK field conditions. In the first study, a total of 40 animals were allocated into 4 treatment groups, and were either left untreated or treated with DQL+ABA, MOX or ABA. Faecal samples were collected on days 1-5 and on day 7 after treatment to examine the reduction in faecal egg excretion and to evaluate the egg viability. On day 14 post treatment all animals were euthanised for abomasal worm counts. There was a 100% reduction in geometric mean worm counts for the DQL+ABA treated animals compared to the untreated control animals (P<0.0001), whereas the percentage reduction in worm counts for the MOX- (P>0.05) and ABA-treated (P=0.0004) animals was 12.4% and 71.8%, respectively. The data from the egg hatch assay (EHA) indicated that in the MOX-treated and the ABA-treated animals, the majority of the eggs hatched after treatment. In the field study, performed on four farms, animals were allocated into 6 groups of 11-15 animals each in order to conduct a faecal egg count reduction test (FECRT), based on arithmetic mean egg counts. One group of animals remained untreated, whereas the other animals were treated with DQL+ABA, MOX, fenbendazole (FBZ), levamisole (LV) or ivermectin (IVM). On each of the farms the reduction in egg excretion after treatment with FBZ, LV or IVM was below 95.0%, indicating anthelmintic resistance. The efficacy of DQL+ABA ranged from 99.1 to 100%, yielding significantly lower egg counts compared to the untreated control group (P ≤ 0.003). For MOX the egg counts were significantly (P ≤ 0.003) lower compared to the untreated group at each farm, with reductions varying from 98.2 to 100%. The post-treatment copro-cultures for larva identification indicated that T. circumcincta was the most abundant worm species after treatment (52-99% of the larvae). The results of these studies confirm the high efficacy of the DQL+ABA combination formulation against anthelmintic resistant nematodes in the UK. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Shot Group Statistics for Small Arms Applications

    DTIC Science & Technology

    2017-06-01

    standard deviation. Analysis is presented as applied to one , n-round shot group and then is extended to treat multiple, n-round shot groups. A...dispersion measure for multiple, n-round shot groups can be constructed by selecting one of the dispersion measures listed above, measuring the dispersion of...as applied to one , n-round shot group and then is extended to treat multiple, n-round shot groups. A dispersion measure for multiple, n- round shot

  16. You can't measure what you can't see - detectors for microscopies

    NASA Astrophysics Data System (ADS)

    Denes, Peter

    For centuries, the human eye has been the imaging detector of choice thanks to its high sensitivity, wide dynamic range, and direct connection to a built-in data recording and analysis system. The eye, however, is limited to visible light, which excludes microscopies with electrons and X-rays, and the built-in recording system stores archival information at very low rates. The former limitation has been overcome by ``indirect'' detectors, which convert probe particles to visible light, and the latter by a variety of recording techniques, from photographic film to semiconductor-based imagers. Semiconductor imagers have been used for decades as ``direct'' detectors in particle physics, and almost as long for hard X-rays. For soft X-ray microscopy, the challenge has been the small signal levels - plus getting the X-rays into the detector itself, given how quickly they are absorbed in inert layers. For electron microscopy, the challenge has been reconciling detector spatial resolution and pixel count with the large multiple scattering of electrons with energies used for microscopy. Further, a high recording rate (``movies'' rather than ``snapshots'') enables time-resolved studies, time-dependent corrections, shot-by-shot experiments and scanning techniques - at the expense of creating large data volumes. This talk will discuss solutions to these challenges, as well as an outlook towards future developments.

  17. The Effect of Multiple Shot Peening on the Corrosion Behavior of Duplex Stainless Steel

    NASA Astrophysics Data System (ADS)

    Feng, Qiang; She, Jia; Wu, Xueyan; Wang, Chengxi; Jiang, Chuanhai

    2018-03-01

    Various types of shot peening treatments were applied to duplex stainless steel. The effects of shot peening intensity and working procedures on the microstructure were investigated. The domain size and microstrain evolution in the surface layer were characterized utilizing the Rietveld method. As the shot peening intensity increased, the surface roughness increased in the surface layer; however, it decreased after multiple (dual and triple) shot peening. The mole fraction of strain-induced martensite as a function of the intensity of shot peening was evaluated by XRD measurements. Both potentiodynamic polarization curves and salt spray tests of shot-peened samples in NaCl solution were investigated. The results indicate that traditional shot peening has negative effects on corrosion resistance with increasing shot peening intensity; however, the corrosion rate can be reduced by means of multiple shot peening.

  18. Shot Ingestion by Wintering Female Northern Pintails (Anas acuta) in the Texas Coastal Plain, 2012-14.

    PubMed

    Huck, Nathaniel R; Ballard, Bart M; Fedynich, Alan M; Kraai, Kevin J; Castro, Mauro E

    2016-01-01

    Historically, lead poisoning through lead shot ingestion was one of the largest health issues affecting waterfowl in North America. Lead shot was banned for use in waterfowl hunting in the US in 1991 and was banned in Canada in 1997. However, biologists need to understand how, and if, lead shot remaining in the environment will continue to impact waterfowl. Our goal was to estimate lead and nontoxic shot consumption by female Northern Pintails (Anas acuta) wintering along the Texas coast. We found shot or metal fragments (or both) in the gizzards of 39 (17%) of 227 female Northern Pintails collected along the Texas coast. Of these, lead shot was found in seven gizzards, steel shot was found in 24 gizzards, and other metal and fragments were found in 20 gizzards. Some females consumed multiple shot types. Overall, shot (lead and nontoxic combined) ingestion rates were similar to those found prior to the lead shot ban in Texas (14%) and Louisiana (17%); however, lead shot ingestion rates were considerably lower, suggesting that it is becoming less available over time. All Northern Pintails that had lead shot in their gizzards were collected from coastal habitats. While it seems that lead shot ingestion by Northern Pintails has decreased since the ban was put in place, monitoring lead shot ingestion rates from different regions will provide insight into its availability in different habitats and under various environmental conditions.

  19. Lead shot toxicity to passerines

    USGS Publications Warehouse

    Vyas, N.B.; Spann, J.W.; Heinz, G.H.

    2001-01-01

    This study evaluated the toxicity of a single size 7.5 lead shot to passerines. No mortalities or signs of plumbism were observed in dosed cowbirds (Molothrus ater) fed a commercial diet, but when given a more natural diet, three of 10 dosed birds died within 1 day. For all survivors from which shot were recovered, all but one excreted the shot within 24 h of dosing, whereas, the dead birds retained their shot. Shot erosion was significantly greater (P < 0.05) when weathered shot were ingested compared to new shot, and the greatest erosion was observed in those birds that died (2.2-9.7%). Blood lead concentrations of birds dosed with new shot were not significantly different (P=0.14) from those of birds exposed to weathered shot. Liver lead concentrations of birds that died ranged from 71 to 137 ppm, dry weight. Despite the short amount of time the shot was retained, songbirds may absorb sufficient lead to compromise their survival.

  20. Initial results from the rebuilt EXTRAP T2R RFP device

    NASA Astrophysics Data System (ADS)

    Brunsell, P. R.; Bergsåker, H.; Cecconello, M.; Drake, J. R.; Gravestijn, R. M.; Hedqvist\\ad{2 }, A.; Malmberg, J.-A.

    2001-11-01

    The EXTRAP T2R thin shell reversed-field pinch (RFP) device has recently resumed operation after a major rebuild including the replacement of the graphite armour with molybdenum limiters, a fourfold increase of the shell time constant, and the replacement of the helical coil used for the toroidal field with a conventional solenoid-type coil. Wall-conditioning using hydrogen glow discharge cleaning was instrumental for successful RFP operation. Carbon was permanently removed from the walls during the first week of operation. The initial results from RFP operation with relatively low plasma currents in the range Ip = 70-100 kA are reported. RFP discharges are sustained for more than three shell times. Significant improvements in plasma parameters are observed, compared to operation before the rebuild. There is a substantial reduction in the carbon impurity level. The electron density behaviour is more shot-to-shot reproducible. The typical density is ne = 0.5-1×1019 m-3. Monitors of Hα line radiation indicate that the plasma wall interaction is more toroidally symmetric and that there is less transient gas release from the wall. The minimum loop voltage is in the range Vt = 28-35 V, corresponding to a reduction by a factor of two to three compared to the value before the rebuild.

  1. POCS-based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): a general algorithm for reducing motion-related artifacts

    PubMed Central

    Chu, Mei-Lan; Chang, Hing-Chiu; Chung, Hsiao-Wen; Truong, Trong-Kha; Bashir, Mustafa R.; Chen, Nan-kuei

    2014-01-01

    Purpose A projection onto convex sets reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE) is developed to reduce motion-related artifacts, including respiration artifacts in abdominal imaging and aliasing artifacts in interleaved diffusion weighted imaging (DWI). Theory Images with reduced artifacts are reconstructed with an iterative POCS procedure that uses the coil sensitivity profile as a constraint. This method can be applied to data obtained with different pulse sequences and k-space trajectories. In addition, various constraints can be incorporated to stabilize the reconstruction of ill-conditioned matrices. Methods The POCSMUSE technique was applied to abdominal fast spin-echo imaging data, and its effectiveness in respiratory-triggered scans was evaluated. The POCSMUSE method was also applied to reduce aliasing artifacts due to shot-to-shot phase variations in interleaved DWI data corresponding to different k-space trajectories and matrix condition numbers. Results Experimental results show that the POCSMUSE technique can effectively reduce motion-related artifacts in data obtained with different pulse sequences, k-space trajectories and contrasts. Conclusion POCSMUSE is a general post-processing algorithm for reduction of motion-related artifacts. It is compatible with different pulse sequences, and can also be used to further reduce residual artifacts in data produced by existing motion artifact reduction methods. PMID:25394325

  2. High linearity SPAD and TDC array for TCSPC and 3D ranging applications

    NASA Astrophysics Data System (ADS)

    Villa, Federica; Lussana, Rudi; Bronzi, Danilo; Dalla Mora, Alberto; Contini, Davide; Tisa, Simone; Tosi, Alberto; Zappa, Franco

    2015-01-01

    An array of 32x32 Single-Photon Avalanche-Diodes (SPADs) and Time-to-Digital Converters (TDCs) has been fabricated in a 0.35 μm automotive-certified CMOS technology. The overall dimension of the chip is 9x9 mm2. Each pixel is able to detect photons in the 300 nm - 900 nm wavelength range with a fill-factor of 3.14% and either to count them or to time stamp their arrival time. In photon-counting mode an in-pixel 6-bit counter provides photon-numberresolved intensity movies at 100 kfps, whereas in photon-timing mode the 10-bit in-pixel TDC provides time-resolved maps (Time-Correlated Single-Photon Counting measurements) or 3D depth-resolved (through direct time-of-flight technique) images and movies, with 312 ps resolution. The photodetector is a 30 μm diameter SPAD with low Dark Count Rate (120 cps at room temperature, 3% hot-pixels) and 55% peak Photon Detection Efficiency (PDE) at 450 nm. The TDC has a 6-bit counter and a 4-bit fine interpolator, based on a Delay Locked Loop (DLL) line, which makes the TDC insensitive to process, voltage, and temperature drifts. The implemented sliding-scale technique improves linearity, giving 2% LSB DNL and 10% LSB INL. The single-shot precision is 260 ps rms, comprising SPAD, TDC and driving board jitter. Both optical and electrical crosstalk among SPADs and TDCs are negligible. 2D fast movies and 3D reconstructions with centimeter resolution are reported.

  3. 77 FR 14564 - Information Collection Request Sent to the Office of Management and Budget (OMB) for Approval...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-12

    ...; Approval Procedures for Nontoxic Shot and Shot Coatings AGENCY: Fish and Wildlife Service, Interior. ACTION... Number: 1018-0067. Title: Approval Procedures for Nontoxic Shot and Shot Coatings, 50 CFR 20.134. Service... Respondents: Businesses that produce and/or market approved nontoxic shot types or nontoxic shot coatings...

  4. 78 FR 65573 - Migratory Bird Hunting; Application for Approval of Copper-Clad Iron Shot and Fluoropolymer Shot...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-01

    ... supported approval of the shot and the coatings, and one contained no useful information. Therefore, as... Hunting; Application for Approval of Copper-Clad Iron Shot and Fluoropolymer Shot Coatings as Nontoxic for... environmental assessments. SUMMARY: We, the U.S. Fish and Wildlife Service, approve copper-clad iron shot and...

  5. Rolling contact fatigue strengths of shot-peened and crack-healed ceramics

    NASA Astrophysics Data System (ADS)

    Takahashi, K.; Oki, T.

    2018-06-01

    The effects of shot-peening (SP) and crack-healing on the rolling contact fatigue (RCF) strengths of Al2O3/SiC composite ceramics were investigated. Non-shot-peened, shot- peened, and shot-peened + crack-healed specimens were prepared. SP was performed using ZrO2 beads. The shot-peened + crack-healed specimen was crack-healed after SP. X-ray diffraction clearly showed that SP induced a compressive residual stress up to 300 MPa at the specimen surfaces. Furthermore, the shot-peened + crack-healed specimen retained a compressive residual stress of 200 MPa. The apparent surface fracture toughness of the shot- peened specimens increased owing to the positive effects of the compressive residual stress. RCF tests were performed using a thrust load-bearing test device. The RCF lives of the shot- peened specimens did not improve compared to that of the non-shot-peened specimen, because the numerous SP-introduced surface cracks could act as crack initiation sites during the RCF tests. However, the RCF life of the shot-peened + crack-healed specimen did improve compared to those of non-shot-peened and shot-peened specimens, implying that combining SP and crack-healing was an effective strategy for improving the RCF lives of Al2O3/SiC composite ceramics.

  6. FY16 LLNL Omega Experimental Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heeter, R. F.; Ali, S. J.; Benstead, J.

    In FY16, LLNL’s High-Energy-Density Physics (HED) and Indirect Drive Inertial Confinement Fusion (ICF-ID) programs conducted several campaigns on the OMEGA laser system and on the EP laser system, as well as campaigns that used the OMEGA and EP beams jointly. Overall, these LLNL programs led 430 target shots in FY16, with 304 shots using just the OMEGA laser system, and 126 shots using just the EP laser system. Approximately 21% of the total number of shots (77 OMEGA shots and 14 EP shots) supported the Indirect Drive Inertial Confinement Fusion Campaign (ICF-ID). The remaining 79% (227 OMEGA shots and 112more » EP shots) were dedicated to experiments for High-Energy-Density Physics (HED). Highlights of the various HED and ICF campaigns are summarized in the following reports. In addition to these experiments, LLNL Principal Investigators led a variety of Laboratory Basic Science campaigns using OMEGA and EP, including 81 target shots using just OMEGA and 42 shots using just EP. The highlights of these are also summarized, following the ICF and HED campaigns. Overall, LLNL PIs led a total of 553 shots at LLE in FY 2016. In addition, LLNL PIs also supported 57 NLUF shots on Omega and 31 NLUF shots on EP, in collaboration with the academic community.« less

  7. FY15 LLNL OMEGA Experimental Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heeter, R. F.; Baker, K. L.; Barrios, M. A.

    In FY15, LLNL’s High-Energy-Density Physics (HED) and Indirect Drive Inertial Confinement Fusion (ICF-ID) programs conducted several campaigns on the OMEGA laser system and on the EP laser system, as well as campaigns that used the OMEGA and EP beams jointly. Overall these LLNL programs led 468 target shots in FY15, with 315 shots using just the OMEGA laser system, 145 shots using just the EP laser system, and 8 Joint shots using Omega and EP together. Approximately 25% of the total number of shots (56 OMEGA shots and 67 EP shots, including the 8 Joint shots) supported the Indirect Drivemore » Inertial Confinement Fusion Campaign (ICF-ID). The remaining 75% (267 OMEGA shots and 86 EP shots) were dedicated to experiments for High-Energy-Density Physics (HED). Highlights of the various HED and ICF campaigns are summarized in the following reports.« less

  8. Single-shot speckle reduction in numerical reconstruction of digitally recorded holograms: comment.

    PubMed

    Maycock, Jonathan; Hennelly, Bryan; McDonald, John

    2015-09-01

    We comment on a recent Letter by Hincapie et al. [Opt. Lett.40, 1623 (2015)], in which the authors proposed a method to reduce the speckle noise in digital holograms. This method was previously published by us in Maycock ["Improving reconstructions of digital holograms," Ph.D. thesis (National University of Ireland, 2012)] and Maycock and Hennelly [Improving Reconstructions of Digital Holograms: Speckle Reduction and Occlusions in Digital Holography (Lambert Academic, 2014)]. We also wish to highlight an important limitation of the method resulting from the superposition of different perspectives of the object/scene, which was not addressed in their Letter.

  9. 77 FR 59158 - Migratory Bird Hunting; Application for Approval of Copper-Clad Iron Shot and Fluoropolymer Shot...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-26

    ... June 20, 2012 (77 FR 36980), and one for the fluoropolymer shot coatings on July 6, 2012 (77 FR 39983... Bird Hunting; Application for Approval of Copper-Clad Iron Shot and Fluoropolymer Shot Coatings as... approve copper-clad iron shot and fluoropolymer coatings for hunting waterfowl and coots. We published a...

  10. On the Path to SunShot. Utility Regulatory and Business Model Reforms for Addressing the Financial Impacts of Distributed Solar on Utilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barbose, Galen; Miller, John; Sigrin, Ben

    Net-energy metering (NEM) has helped drive the rapid growth of distributed PV (DPV) but has raised concerns about electricity cost shifts, utility financial losses, and inefficient resource allocation. These concerns have motivated real and proposed reforms to utility regulatory and business models. This report explores the challenges and opportunities associated with such reforms in the context of the U.S. Department of Energy's SunShot Initiative. Most of the reforms to date address NEM concerns by reducing the benefits provided to DPV customers and thus constraining DPV deployment. Eliminating NEM nationwide, by compensating exports of PV electricity at wholesale rather than retailmore » rates, could cut cumulative DPV deployment by 20% in 2050 compared with a continuation of current policies. This would slow the PV cost reductions that arise from larger scale and market certainty. It could also thwart achievement of the SunShot deployment goals even if the initiative's cost targets are achieved. This undesirable prospect is stimulating the development of alternative reform strategies that address concerns about distributed PV compensation without inordinately harming PV economics and growth. These alternatives fall into the categories of facilitating higher-value DPV deployment, broadening customer access to solar, and aligning utility profits and earnings with DPV. Specific strategies include utility ownership and financing of DPV, community solar, distribution network operators, services-driven utilities, performance-based incentives, enhanced utility system planning, pricing structures that incentivize high-value DPV configurations, and decoupling and other ratemaking reforms that reduce regulatory lag. These approaches represent near- and long-term solutions for preserving the legacy of the SunShot Initiative.« less

  11. Factors affecting the inactivation of the natural microbiota of milk processed by pulsed electric fields and cross-flow microfiltration.

    PubMed

    Rodríguez-González, Oscar; Walkling-Ribeiro, Markus; Jayaram, Shesha; Griffiths, Mansel W

    2011-08-01

    Prior to processing milk and cream were standardised and homogenised. Skim milk was cross-flow microfiltered (CFMF) prior to treatment with pulsed electric fields (PEF) or high temperature short time (HTST) pasteurization. The effect of temperature of the skim milk and product composition on the efficacy of PEF treatment was determined. The electrical conductivity of the product was related to fat and solids content and increased 5% for every g/kg increase of solids and decreased by nearly 0·7% for every g/kg increase of fat. From the three microbial groups analyzed (mesophilic, coliform, and psychrotroph) in milks differences (P<0·05) in the inactivation of mesophilic microorganisms were observed between the counts following PEF treatment, while HTST pasteurization resulted in higher reductions in all different counts than those obtained after PEF. Increasing the skim milk temperature prior to PEF treatment to about 34°C showed equivalent reductions in microbial counts to skim milk treated at 6°C in half the time. The reductions achieved by a combination of CFMF and PEF treatments were comparable to those achieved when CFMF was combined with HTST pasteurization. A higher reduction in coliform counts was observed in homogenised products subjected to PEF than in products that were only standardised for fat content.

  12. Investigation of industrial-scale carbon dioxide reduction using pulsed electron beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrov, G. M.; Apruzese, J. P.; Petrova, Tz. B.

    Carbon dioxide is the most important greenhouse gas contributing to global warming. To help mitigate increasing CO{sub 2} concentrations, we investigate a method of carbon dioxide reduction using high-power electron beams, which can be used on an industrial scale. A series of experiments are conducted in which the reduction of CO{sub 2} is measured for different gas compositions and power deposition rates. An electron beam deposition model is applied to compute reduction rates of CO{sub 2} and energy cost for breaking a CO{sub 2} molecule in flue gas and pure carbon dioxide at atmospheric pressure. For flue gas consisting ofmore » 82% N{sub 2}, 6% O{sub 2}, and 12% CO{sub 2}, the calculated energy cost is 85 eV per molecule. In order to dissociate 50% of the CO{sub 2} molecules, beam energy density deposition on the order of 20 J/cm{sup 3} is required. Electron beam irradiation of 12.6 liter gas volume containing 90% CO{sub 2} and 10% CH{sub 4} at beam energy density deposition of 4.2 J/cm{sup 3}, accumulated over 43 shots in a 20 min interval, reduced the CO{sub 2} concentration to 78%. Analogous experiments with a gas mixture containing 11.5% CO{sub 2}, 11.5% CH{sub 4}, and balance of Ar, reduced the CO{sub 2} concentration to below 11% with energy deposition 0.71 J/cm{sup 3}, accumulated over 10 shots in a 5 min interval. The experimental data and the theoretical predictions of CO{sub 2} reduction using pulsed electron beams are in agreement within the experimental error. Other techniques to enhance the removal of CO{sub 2} with pulsed electron beams are also explored, yielding new possible avenues of research.« less

  13. Comparison of Kato-Katz thick-smear and McMaster egg counting method for the assessment of drug efficacy against soil-transmitted helminthiasis in school children in Jimma Town, Ethiopia.

    PubMed

    Bekana, Teshome; Mekonnen, Zeleke; Zeynudin, Ahmed; Ayana, Mio; Getachew, Mestawet; Vercruysse, Jozef; Levecke, Bruno

    2015-10-01

    There is a paucity of studies that compare efficacy of drugs obtained by different diagnostic methods. We compared the efficacy of a single oral dose albendazole (400 mg), measured as egg reduction rate, against soil-transmitted helminth infections in 210 school children (Jimma Town, Ethiopia) using both Kato-Katz thick smear and McMaster egg counting method. Our results indicate that differences in sensitivity and faecal egg counts did not imply a significant difference in egg reduction rate estimates. The choice of a diagnostic method to assess drug efficacy should not be based on sensitivity and faecal egg counts only. © The Author 2015. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Effectiveness evaluation of several cattle anthelmintics via the fecal egg count reduction test.

    PubMed

    Yazwinski, T A; Tucker, C A; Hornsby, J A; Powell, J G; Reynolds, J L; Johnson, Z B; Lindsey, W; Silver, T K

    2009-07-01

    Utilizing groups of cograzed, naturally infected beef-type heifers, three fecal egg count reduction tests were conducted in the later months of 2007 at the University of Arkansas. Each test was 28 days in length consisting of individual animal fecal nematode egg counts and coprocultures. Both original and generic ivermectin injectable formulations were used in two of the tests at 0.2 mg/kg BW, with FECR percentages never exceeding 90% in either test. Oral fenbendazole was evaluated at 5 and 10 mg/kg BW, with FECR%'s exceeding 90% on all occasions, but with a precipitous drop when recently treated animals were treated at the lower dose. Evaluated in one test, injectable moxidectin given at 0.2 mg/kg BW resulted in egg count reductions of 96-92% (days 7 to 28). Also evaluated in one test, albendazole delivered orally at 10 mg/kg BW was 98% and 97% effective at 17 and 28 days post-treatment. For all tests, coprocultures conducted post-treatment contained only Cooperia spp. larvae (benzimidazole use), relatively unmodified percentages of Cooperia spp. and Haemonchus spp. larvae (ivermectin use), and primarily Cooperia spp. larvae with a small percentage of Haemonchus spp. larvae (moxidectin use).

  15. A systematic examination of the bone destruction pattern of the two-shot technique

    PubMed Central

    Stoetzer, Marcus; Stoetzer, Carsten; Rana, Majeed; Zeller, Alexander; Hanke, Alexander; Gellrich, Nils-Claudius; von See, Constantin

    2014-01-01

    Introduction: The two-shot technique is an effective stopping power method. The precise mechanisms of action on the bone and soft-tissue structures of the skull; however, remain largely unclear. The aim of this study is to compare the terminal ballistics of the two-shot and single-shot techniques. Materials and Methods: 40 fresh pigs’ heads were randomly divided into 4 groups (n = 10). Either a single shot or two shots were fired at each head with a full metal jacket or a semi-jacketed bullet. Using thin-layer computed tomography and photography, the diameter of the destruction pattern and the fractures along the bullet path were then imaged and assessed. Results: A single shot fired with a full metal jacket bullet causes minor lateral destruction along the bullet path. With two shots fired with a full metal jacket bullet, however, the maximum diameter of the bullet path is significantly greater (P < 0.05) than it is with a single shot fired with a full metal jacket bullet. In contrast, the maximum diameter with a semi-jacketed bullet is similar with the single-shot and two-shot techniques. Conclusion: With the two-shot technique, a full metal jacket bullet causes a destruction pattern that is comparable to that of a single shot fired with a semi-jacketed bullet. PMID:24812454

  16. Dialog detection in narrative video by shot and face analysis

    NASA Astrophysics Data System (ADS)

    Kroon, B.; Nesvadba, J.; Hanjalic, A.

    2007-01-01

    The proliferation of captured personal and broadcast content in personal consumer archives necessitates comfortable access to stored audiovisual content. Intuitive retrieval and navigation solutions require however a semantic level that cannot be reached by generic multimedia content analysis alone. A fusion with film grammar rules can help to boost the reliability significantly. The current paper describes the fusion of low-level content analysis cues including face parameters and inter-shot similarities to segment commercial content into film grammar rule-based entities and subsequently classify those sequences into so-called shot reverse shots, i.e. dialog sequences. Moreover shot reverse shot specific mid-level cues are analyzed augmenting the shot reverse shot information with dialog specific descriptions.

  17. Relative toxicity of lead and selected substitute shot types to game farm mallards

    USGS Publications Warehouse

    Irby, H.D.; Locke, L.N.; Bagley, George E.

    1967-01-01

    The acute toxicity of lead, three types of plastic-coated lead, two lead-magnesium alloys, iron, copper, zinc-coated iron, and molybdenum-coated iron shot were tested in year-old male game farm mallards. Mallards (Anus platyrhynchos) were fed eight number 6 shot of each type and observed for a period of 60 days. Ducks used totaled 230 and most shot types were tested in three replicates of 8 ducks each. Mortality and losses of body weight were the criteria used for judging toxicity. Three types of plastic-coated lead shot were as toxic (93 percent) as the commercial lead shot (96 percent). The average mortality in mallards fed lead-magnesium alloy shot was less (58 percent) than that occurring in birds fed commercial lead shot. Mortality among mallards fed iron, copper, zinc-coated iron or molybdenum-coated iron shot was significantly less than in birds fed lead shot, and was not significantly greater than the conrtols.

  18. Parameter Estimation with Entangled Photons Produced by Parametric Down-Conversion

    NASA Technical Reports Server (NTRS)

    Cable, Hugo; Durkin, Gabriel A.

    2010-01-01

    We explore the advantages offered by twin light beams produced in parametric down-conversion for precision measurement. The symmetry of these bipartite quantum states, even under losses, suggests that monitoring correlations between the divergent beams permits a high-precision inference of any symmetry-breaking effect, e.g., fiber birefringence. We show that the quantity of entanglement is not the key feature for such an instrument. In a lossless setting, scaling of precision at the ultimate "Heisenberg" limit is possible with photon counting alone. Even as photon losses approach 100% the precision is shot-noise limited, and we identify the crossover point between quantum and classical precision as a function of detected flux. The predicted hypersensitivity is demonstrated with a Bayesian simulation.

  19. Parameter estimation with entangled photons produced by parametric down-conversion.

    PubMed

    Cable, Hugo; Durkin, Gabriel A

    2010-07-02

    We explore the advantages offered by twin light beams produced in parametric down-conversion for precision measurement. The symmetry of these bipartite quantum states, even under losses, suggests that monitoring correlations between the divergent beams permits a high-precision inference of any symmetry-breaking effect, e.g., fiber birefringence. We show that the quantity of entanglement is not the key feature for such an instrument. In a lossless setting, scaling of precision at the ultimate "Heisenberg" limit is possible with photon counting alone. Even as photon losses approach 100% the precision is shot-noise limited, and we identify the crossover point between quantum and classical precision as a function of detected flux. The predicted hypersensitivity is demonstrated with a Bayesian simulation.

  20. Topologically protected charge transfer along the edge of a chiral p -wave superconductor

    NASA Astrophysics Data System (ADS)

    Gnezdilov, N. V.; van Heck, B.; Diez, M.; Hutasoit, Jimmy A.; Beenakker, C. W. J.

    2015-09-01

    The Majorana fermions propagating along the edge of a topological superconductor with px+i py pairing deliver a shot noise power of 1/2 ×e2/h per eV of voltage bias. We calculate the full counting statistics of the transferred charge and find that it becomes trinomial in the low-temperature limit, distinct from the binomial statistics of charge-e transfer in a single-mode nanowire or charge-2 e transfer through a normal-superconductor interface. All even-order correlators of current fluctuations have a universal quantized value, insensitive to disorder and decoherence. These electrical signatures are experimentally accessible, because they persist for temperatures and voltages large compared to the Thouless energy.

  1. High-speed multi-exposure laser speckle contrast imaging with a single-photon counting camera

    PubMed Central

    Dragojević, Tanja; Bronzi, Danilo; Varma, Hari M.; Valdes, Claudia P.; Castellvi, Clara; Villa, Federica; Tosi, Alberto; Justicia, Carles; Zappa, Franco; Durduran, Turgut

    2015-01-01

    Laser speckle contrast imaging (LSCI) has emerged as a valuable tool for cerebral blood flow (CBF) imaging. We present a multi-exposure laser speckle imaging (MESI) method which uses a high-frame rate acquisition with a negligible inter-frame dead time to mimic multiple exposures in a single-shot acquisition series. Our approach takes advantage of the noise-free readout and high-sensitivity of a complementary metal-oxide-semiconductor (CMOS) single-photon avalanche diode (SPAD) array to provide real-time speckle contrast measurement with high temporal resolution and accuracy. To demonstrate its feasibility, we provide comparisons between in vivo measurements with both the standard and the new approach performed on a mouse brain, in identical conditions. PMID:26309751

  2. Cellular imaging using temporally flickering nanoparticles.

    PubMed

    Ilovitsh, Tali; Danan, Yossef; Meir, Rinat; Meiri, Amihai; Zalevsky, Zeev

    2015-02-04

    Utilizing the surface plasmon resonance effect in gold nanoparticles enables their use as contrast agents in a variety of applications for compound cellular imaging. However, most techniques suffer from poor signal to noise ratio (SNR) statistics due to high shot noise that is associated with low photon count in addition to high background noise. We demonstrate an effective way to improve the SNR, in particular when the inspected signal is indistinguishable in the given noisy environment. We excite the temporal flickering of the scattered light from gold nanoparticle that labels a biological sample. By preforming temporal spectral analysis of the received spatial image and by inspecting the proper spectral component corresponding to the modulation frequency, we separate the signal from the wide spread spectral noise (lock-in amplification).

  3. The Problem of Shot Selection in Basketball

    PubMed Central

    Skinner, Brian

    2012-01-01

    In basketball, every time the offense produces a shot opportunity the player with the ball must decide whether the shot is worth taking. In this article, I explore the question of when a team should shoot and when they should pass up the shot by considering a simple theoretical model of the shot selection process, in which the quality of shot opportunities generated by the offense is assumed to fall randomly within a uniform distribution. Within this model I derive an answer to the question “how likely must the shot be to go in before the player should take it?” and I show that this lower cutoff for shot quality depends crucially on the number of shot opportunities remaining (say, before the shot clock expires), with larger demanding that only higher-quality shots should be taken. The function is also derived in the presence of a finite turnover rate and used to predict the shooting rate of an optimal-shooting team as a function of time. The theoretical prediction for the optimal shooting rate is compared to data from the National Basketball Association (NBA). The comparison highlights some limitations of the theoretical model, while also suggesting that NBA teams may be overly reluctant to shoot the ball early in the shot clock. PMID:22295109

  4. The problem of shot selection in basketball.

    PubMed

    Skinner, Brian

    2012-01-01

    In basketball, every time the offense produces a shot opportunity the player with the ball must decide whether the shot is worth taking. In this article, I explore the question of when a team should shoot and when they should pass up the shot by considering a simple theoretical model of the shot selection process, in which the quality of shot opportunities generated by the offense is assumed to fall randomly within a uniform distribution. Within this model I derive an answer to the question "how likely must the shot be to go in before the player should take it?" and I show that this lower cutoff for shot quality f depends crucially on the number n of shot opportunities remaining (say, before the shot clock expires), with larger n demanding that only higher-quality shots should be taken. The function f(n) is also derived in the presence of a finite turnover rate and used to predict the shooting rate of an optimal-shooting team as a function of time. The theoretical prediction for the optimal shooting rate is compared to data from the National Basketball Association (NBA). The comparison highlights some limitations of the theoretical model, while also suggesting that NBA teams may be overly reluctant to shoot the ball early in the shot clock.

  5. Comparative evaluation of antibacterial property and substantivity of chlorhexidine containing dentifrices with sodium lauryl sulfate and Tween as surfactants: an in vivo study.

    PubMed

    Venu, V; Prabhakar, A R; Basappa, N

    2013-01-01

    The aim of the study was to determine the antibacterial property and substantivity of chlorhexidine containing dentifrices with sodium lauryl sulfate (SLS) and Tween as surfactants. It is a double-blind cross over the study, a total of 20 children within their mixed dentition period (7-13 year) having Streptococci mutans count more than 10(6) were selected for the main study. Three types of chlorhexidine containing dentifrices were used with a washout period of 1 week. Out of the three toothpastes, one was without surfactant and other two toothpastes contained SLS and Tween as surfactants respectively. 20 volunteers brushed for 1 min during the study day with their assigned toothpaste. Saliva samples were collected before brushing, immediately after brushing and 1, 3, 5, and 7 hand sent for microbial analysis. The culture carried out by inoculating saliva sample onto Mitis salivarius agar for selective isolation of S. mutans followed by counting of colony forming unit. Group I and III (Chlorhexidine and CHX + Tween) had shown statistically significant reduction in bacterial count until 7 h when compared to their baseline values ( P < 0.001). Group II toothpaste (CHX + SLS) had shown significant reduction in bacterial count until 3 h only. On inter group comparison, Group III had shown good amount of percentage reduction in bacterial count when compared to other groups. CHX + Tween toothpaste had shown statistically significant reduction in antibacterial activity and substantivity than other groups. These findings show chlorhexidine containing toothpaste with non-ionic surfactant will be able to maintain the antibacterial property and substantivity of chlorhexidine.

  6. Field suppression of the invasive ant Wasmannia auropunctata (Hymenoptera: Formicidae) in a tropical fruit orchard in Hawaii.

    PubMed

    Souza, Evann; Follett, Peter A; Price, Don K; Stacy, Elizabeth A

    2008-08-01

    The little fire ant, Wasmannia auropunctata (Roger) (Hymenoptera: Formicidae), is an invasive ant that forms supercolonies when it successfully invades new areas. W. auropunctata was first reported in Hawaii in 1999, and it has since invaded a variety of agricultural sites, including nurseries, orchards, and pastures. Amdro (hydramethylnon; in bait stations), Esteem (pyriproxyfen; broadcast bait), and Conserve (spinosad; ground spray) were tested for their efficacy against W. auropunctata in a rambutan, Nephelium lappaceum L. and mangosteen, Garcinia mangostana L., orchard by making treatments every 2 wk for 16 wk. Relative estimates of ant numbers in plots was determined by transect sampling using peanut butter-baited sticks. Significant treatment effects were observed on weeks 13-17, with reductions in ant counts occurring in the Amdro and Esteem treatments. During this period, the reduction in ant numbers from pretreatment counts averaged 47.1 and 92.5% in the Amdro and Esteem plots, respectively, whereas ant numbers in the untreated control plots increased by 185.9% compared with pretreatment counts. Conserve did not cause a reduction in ant counts as applied in our experiment. No plots for any of the treatments achieved 100% reduction. Pseudococcidae were counted on branch terminals at 4-wk intervals. The two predominant species, Nipaecoccus nipae (Maskell) and Nipaecoccus viridis (Newstead) were significantly lower in the Amdro and Esteem treatments on week 16 compared with controls. Many W. auropunctata were found nesting in protected sites in the orchard trees, which may have compromised the ground-based control methods. Absolute density estimates from shallow core samples taken from the orchard floor indicated the W. auropunctata supercolony exceeded 244 million ants and 22.7 kg wet weight per ha.

  7. Spent shot availability and ingestion on areas managed for mourning doves

    USGS Publications Warehouse

    Schulz, J.H.; Millspaugh, J.J.; Washburn, B.E.; Wester, G.R.; Lanigan, J. T.; Franson, J.C.

    2002-01-01

    Mourning dove (Zenaida macroura) hunting is becoming increasingly popular, especially in managed shooting fields. Given the possible increase in the availability of lead (Pb) shot on these areas, our objective was to estimate availability and ingestion of spent shot at the Eagle Bluffs Conservation Area (EBCA, hunted with nontoxic shot) and the James A. Reed Memorial Wildlife Area (JARWA, hunted with Pb shot) in Missouri. During 1998, we collected soil samples one or 2 weeks prior to the hunting season (prehunt) and after 4 days of dove hunting (posthunt). We also collected information on number of doves harvested, number of shots fired, shotgun gauge, and shotshell size used. Dove carcasses were collected on both areas during 1998-99. At EBCA, 60 hunters deposited an estimated 64,775 pellets/ha of nontoxic shot on or around the managed field. At JARWA, approximately 1,086,275 pellets/ha of Pb shot were deposited by 728 hunters. Our posthunt estimates of spent-shot availability from soil sampling were 0 pellets/ha for EBCA and 6,342 pellets/ha for JARWA. Our findings suggest that existing soil sampling protocols may not provide accurate estimates of spent-shot availability in managed dove shooting fields. During 1998-99, 15 of 310 (4.8%) mourning doves collected from EBCA had ingested nontoxic shot. Of those doves, 6 (40.0%) contained a?Y7 shot pellets. In comparison, only 2 of 574 (0.3%) doves collected from JARWA had ingested Pb shot. Because a greater proportion of doves ingested multiple steel pellets compared to Pb pellets, we suggest that doves feeding in fields hunted with Pb shot may succumb to acute Pb toxicosis and thus become unavailable to harvest, resulting in an underestimate of ingestion rates. Although further research is needed to test this hypothesis, our findings may partially explain why previous studies have shown few doves with ingested Pb shot despite their feeding on areas with high Pb shot availability.

  8. Twelve-month results of the rapid renal sympathetic denervation for resistant hypertension using the OneShotTM ablation system (RAPID) study.

    PubMed

    Verheye, Stefan; Ormiston, John; Bergmann, Martin W; Sievert, Horst; Schwindt, Arne; Werner, Nikos; Vogel, Britta; Colombo, Antonio

    2015-02-01

    Renal denervation has emerged as a treatment option for patients with drug-resistant hypertension. This study was designed to assess the safety and effectiveness of the OneShotª Renal Denervation System. RAPID is a prospective, multicentre, single-arm study which enrolled 50 patients at 11 clinical sites in Europe and New Zealand. Eligible patients had an office systolic blood pressure (SBP) ≥160 mmHg and were on a stable regimen of ≥3 antihypertensive medications including a diuretic. The primary safety endpoints were acute procedural safety at discharge and chronic procedural safety at six months. The primary effectiveness endpoint was the rate of office SBP reduction ≥10 mmHg at six months compared to baseline. While not a predefined endpoint, change in 24-hour ambulatory BP was evaluated. The mean baseline office SBP and diastolic BP measurements were 181.6±20.8 and 95.5±15.5 mmHg, respectively. Patients were on a mean of 5.1 antihypertensive medications at baseline. The mean office BP decreased by -20/-8 mmHg (p<0.0001/p=0.0002), and -22/-8 mmHg (p<0.0001/p=0.0014), from baseline to six and 12 months, respectively. The 24-hour ABPM was also significantly reduced by -11/-6 mmHg at six months compared to baseline (p=0.0085/p=0.037). There were no serious adverse events (SAE) at discharge related to groin and vascular access complication or renal artery injury or SAE/adverse device effects at six months. The results of the RAPID study demonstrate safe delivery of RF energy by the OneShot Renal Denervation System for renal sympathetic denervation and sustained efficacy, as evidenced by a significant reduction in office and 24-hour ABPM for six months, which was sustained up to 12 months. ClinicalTrials.gov Identifier: NCT01520506.

  9. Get Important Shots

    MedlinePlus

    ... checkup. Make a plan with your doctor or nurse to get the shots you need. You may also be able to get shots at your local pharmacy. Use this vaccine clinic locator to find out where you can get important shots. Get a seasonal flu shot every year. Remember, everyone age 6 months ...

  10. Effect of shot peening on the residual stress and mechanical behaviour of low-temperature and high-temperature annealed martensitic gear steel 18CrNiMo7-6

    NASA Astrophysics Data System (ADS)

    Yang, R.; Zhang, X.; Mallipeddi, D.; Angelou, N.; Toftegaard, H. L.; Li, Y.; Ahlström, J.; Lorentzen, L.; Wu, G.; Huang, X.

    2017-07-01

    A martensitic gear steel (18CrNiMo7-6) was annealed at 180 °C for 2h and at ˜ 750 °C for 1h to design two different starting microstructures for shot peening. One maintains the original as-transformed martensite while the other contains irregular-shaped sorbite together with ferrite. These two materials were shot peened using two different peening conditions. The softer sorbite + ferrite microstructure was shot peened using 0.6 mm conditioned cut steel shots at an average speed of 25 m/s in a conventional shot peening machine, while the harder tempered martensite steel was shot peened using 1.5 mm steel shots at a speed of 50 m/s in an in-house developed shot peening machine. The shot speeds in the conventional shot peening machine were measured using an in-house lidar set-up. The microstructure of each sample was characterized by optical and scanning electron microscopy, and the mechanical properties examined by microhardness and tensile testing. The residual stresses were measured using an Xstress 3000 G2R diffractometer equipped with a Cr Kα x-ray source. The correspondence between the residual stress profile and the gradient structure produced by shot peening, and the relationship between the microstructure and strength, are analyzed and discussed.

  11. Basketball Shot Types and Shot Success in Different Levels of Competitive Basketball

    PubMed Central

    2015-01-01

    The purpose of our research was to investigate the relative frequencies of different types of basketball shots (above head, hook shot, layup, dunk, tip-in), some details about their technical execution (one-legged, two-legged, drive, cut, …), and shot success in different levels of basketball competitions. We analysed video footage and categorized 5024 basketball shots from 40 basketball games and 5 different levels of competitive basketball (National Basketball Association (NBA), Euroleague, Slovenian 1st Division, and two Youth basketball competitions). Statistical analysis with hierarchical multinomial logistic regression models reveals that there are substantial differences between competitions. However, most differences decrease or disappear entirely after we adjust for differences in situations that arise in different competitions (shot location, player type, and attacks in transition). Differences after adjustment are mostly between the Senior and Youth competitions: more shots executed jumping or standing on one leg, more uncategorised shot types, and more dribbling or cutting to the basket in the Youth competitions, which can all be attributed to lesser technical and physical ability of developing basketball players. The two discernible differences within the Senior competitions are that, in the NBA, dunks are more frequent and hook shots are less frequent compared to European basketball, which can be attributed to better athleticism of NBA players. The effect situational variables have on shot types and shot success are found to be very similar for all competitions. PMID:26038836

  12. Basketball shot types and shot success in different levels of competitive basketball.

    PubMed

    Erčulj, Frane; Štrumbelj, Erik

    2015-01-01

    The purpose of our research was to investigate the relative frequencies of different types of basketball shots (above head, hook shot, layup, dunk, tip-in), some details about their technical execution (one-legged, two-legged, drive, cut, …), and shot success in different levels of basketball competitions. We analysed video footage and categorized 5024 basketball shots from 40 basketball games and 5 different levels of competitive basketball (National Basketball Association (NBA), Euroleague, Slovenian 1st Division, and two Youth basketball competitions). Statistical analysis with hierarchical multinomial logistic regression models reveals that there are substantial differences between competitions. However, most differences decrease or disappear entirely after we adjust for differences in situations that arise in different competitions (shot location, player type, and attacks in transition). Differences after adjustment are mostly between the Senior and Youth competitions: more shots executed jumping or standing on one leg, more uncategorised shot types, and more dribbling or cutting to the basket in the Youth competitions, which can all be attributed to lesser technical and physical ability of developing basketball players. The two discernible differences within the Senior competitions are that, in the NBA, dunks are more frequent and hook shots are less frequent compared to European basketball, which can be attributed to better athleticism of NBA players. The effect situational variables have on shot types and shot success are found to be very similar for all competitions.

  13. 50 CFR 20.134 - Nontoxic shot.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... relevant data, predicting the toxic effect in waterfowl of complete erosion and absorption of one shot or... pellet of lead shot. Dose one group (8 males and 8 females) with eight size No. 4 pellets of steel shot...) and provide commercial breeder mash. Dosing of the 3 groups with one pellet of No. 4 lead shot...

  14. 77 FR 39983 - Migratory Bird Hunting; Application for Approval of Fluoropolymeric Shot Coatings as Nontoxic for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-06

    ... of Fluoropolymeric Shot Coatings as Nontoxic for Waterfowl Hunting AGENCY: Fish and Wildlife Service, Interior. ACTION: Notice of application for nontoxic shot approval. SUMMARY: We, the U.S. Fish and Wildlife Service, announce that Spectra Shot, LLC, of Lafayette, Louisiana, has applied for approval of steel shot...

  15. 50 CFR 20.134 - Nontoxic shot.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... relevant data, predicting the toxic effect in waterfowl of complete erosion and absorption of one shot or... pellet of lead shot. Dose one group (8 males and 8 females) with eight size No. 4 pellets of steel shot...) and provide commercial breeder mash. Dosing of the 3 groups with one pellet of No. 4 lead shot...

  16. 50 CFR 20.134 - Nontoxic shot.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... relevant data, predicting the toxic effect in waterfowl of complete erosion and absorption of one shot or... pellet of lead shot. Dose one group (8 males and 8 females) with eight size No. 4 pellets of steel shot...) and provide commercial breeder mash. Dosing of the 3 groups with one pellet of No. 4 lead shot...

  17. 50 CFR 20.134 - Nontoxic shot.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... relevant data, predicting the toxic effect in waterfowl of complete erosion and absorption of one shot or... pellet of lead shot. Dose one group (8 males and 8 females) with eight size No. 4 pellets of steel shot...) and provide commercial breeder mash. Dosing of the 3 groups with one pellet of No. 4 lead shot...

  18. Continuous video coherence computing model for detecting scene boundaries

    NASA Astrophysics Data System (ADS)

    Kang, Hang-Bong

    2001-07-01

    The scene boundary detection is important in the semantic understanding of video data and is usually determined by coherence between shots. To measure the coherence, two approaches have been proposed. One is a discrete approach and the other one is a continuous approach. In this paper, we use the continuous approach and propose some modifications on the causal First-In-First-Out(FIFO) short-term memory-based model. One modification is that we allow dynamic memory size in computing coherence reliably regardless of the size of each shot. Another modification is that some shots can be removed from the memory buffer not by the FIFO rule. These removed shots have no or small foreground objects. Using this model, we detect scene boundaries by computing shot coherence. In computing coherence, we add one new term which is the number of intermediate shots between two comparing shots because the effect of intermediate shots is important in computing shot recall. In addition, we also consider shot activity because this is important to reflect human perception. We experiment our computing model on different genres of videos and have obtained reasonable results.

  19. Envisioning a Low-Cost Solar Future: Exploring the Potential Impact of Achieving the SunShot 2030 Targets for Photovoltaics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, Wesley J; Frew, Bethany A; Gagnon, Pieter J

    In the context of recent dramatic solar energy cost reductions, the U.S. Department of Energy set new levelized cost of energy goals for photovoltaics (PV) to achieve by 2030 to enable significantly greater PV adoption: $0.03/kWh for utility-scale, $0.04/kWh for commercial, and $0.05/kWh for residential PV systems. We analyze the potential impacts of achieving these 'SunShot 2030' cost targets for the contiguous United States using the Regional Energy Deployment System (ReEDS) and Distributed Generation (dGen) capacity expansion models. We consider the impacts under a wide range of future conditions. We find that PV could provide 13%-18% of U.S. electricity demandmore » in 2030 and 28%-64% of demand if the SunShot 2030 goals are achieved, with PV deployment increasing in every state. The availability of low-cost storage has the largest impact on projected deployment, followed by natural gas prices and electricity demand. For comparison, PV deployed under a business-as-usual scenario could provide only 5% of generation in 2030 and 17% in 2050. We find that the high levels of PV deployment explored here lead to lower electricity prices and system costs, lower carbon dioxide emissions, lower water consumption, increased renewable energy curtailment, and increased storage deployment compared with the business-as-usual scenario.« less

  20. Single-shot pressure-sensitive paint lifetime measurements on fast rotating blades using an optimized double-shutter technique

    NASA Astrophysics Data System (ADS)

    Weiss, Armin; Geisler, Reinhard; Schwermer, Till; Yorita, Daisuke; Henne, Ulrich; Klein, Christian; Raffel, Markus

    2017-09-01

    A pressure-sensitive paint (PSP) system is presented to measure global surface pressures on fast rotating blades. It is dedicated to solve the problem of blurred image data employing the single-shot lifetime method. The efficient blur reduction capability of an optimized double-shutter imaging technique is demonstrated omitting error-prone post-processing or laborious de-rotation setups. The system is applied on Mach-scaled DSA-9A helicopter blades in climb at various collective pitch settings and blade tip Mach and chord Reynolds numbers (M_{ {tip}} = 0.29-0.57; Re_{ {tip}} = 4.63-9.26 × 10^5). Temperature effects in the PSP are corrected by a theoretical approximation validated against measured temperatures using temperature-sensitive paint (TSP) on a separate blade. Ensemble-averaged PSP results are comparable to pressure-tap data on the same blade to within 250 Pa. Resulting pressure maps on the blade suction side reveal spatially high resolved flow features such as the leading edge suction peak, footprints of blade-tip vortices and evidence of laminar-turbulent boundary-layer (BL) transition. The findings are validated by a separately conducted BL transition measurement by means of TSP and numerical simulations using a 2D coupled Euler/boundary-layer code. Moreover, the principal ability of the single-shot technique to capture unsteady flow phenomena is stressed revealing three-dimensional pressure fluctuations at stall.

  1. Vitamin E modifies the ultrastructure of testis and epididymis in mice exposed to lead intoxication.

    PubMed

    Fahim, Mohamed A; Tariq, Saeed; Adeghate, Ernest

    2013-05-01

    Lead (Pb) is known to cause abnormal function of several systems including the male reproductive system, where it has been shown to reduce sperm count. In order to examine the morphological basis of the reduction in sperm count and a possible effect of vitamin E, lead acetate (1 mg/kg body weight) was given to control and vitamin E-treated mice daily, intraperitoneally for 3 weeks. The testis and body of epididymis of the mice were subjected to electron microscopy study. Pb caused degenerative changes in spermatids inducing vacuolization and a reduction in the number of cytoplasmic organelles in Leydig cells. Pb also destroyed the stereocilia of epididymal epithelium. The addition of vitamin E ameliorated the severity of these morphological changes. In conclusion, Pb-induced reduction in sperm count may be due to changes in the ultrastructure of spermatids, epididymal epithelia and Leydig cells. These changes can be reduced by vitamin E. Copyright © 2012 Elsevier GmbH. All rights reserved.

  2. Activity of AFN-1252, a novel FabI inhibitor, against Staphylococcus aureus in an in vitro pharmacodynamic model simulating human pharmacokinetics

    PubMed Central

    Tsuji, Brian T; Harigaya, Yoriko; Lesse, Alan J; Forrest, Alan; Ngo, Dung

    2013-01-01

    AFN-1252, a potent enoyl-ACP reductase (FabI) inhibitor, is under development for the treatment of Staphylococcus aureus infections. The activity of AFN-1252 against two isolates of S. aureus, MSSA 26213 and MRSA S186, was studied in an in vitro pharmacodynamic model simulating AFN-1252 pharmacokinetics in man. Reductions in bacterial viable count over the first 6 hours were generally 1–2 logs and maximal reductions in viable count were generally achieved at fAUC/MIC ratios of 100–200. Maximum reductions in viable count against MSSA 29213 and MRSA S186 were approximately 4 logs, achieved by 450 mg q12h (fAUC/MIC = 1875) dosing at 28 hours. Staphylococcal resistance to AFN-1252 did not develop throughout the 48-hour experiments. As multidrug resistance continues to increase, these studies support the continued investigation of AFN-1252 as a targeted therapeutic for staphylococcal infections. PMID:23433442

  3. Microfilarial reduction following ProHeart® 6 and ProHeart® SR-12 treatment in dogs experimentally inoculated with a resistant isolate of Dirofilaria immitis.

    PubMed

    McTier, Tom L; Pullins, Aleah; Inskeep, Gregory A; Gagnon, Genevieve; Fan, Huihao; Schoell, Adam; Bidgood, Tara; Login, Joyce; Meeus, Patrick

    2017-11-09

    Emerging resistance of heartworms (Dirofilaria immitis) to macrocyclic lactone (ML) preventives is an increasing concern for veterinarians, pet owners and animal health companies that supply heartworm preventives, with recent reports of resistant isolates identified from the Mississippi Delta region of the United States. Products that are effective in eliminating microfilariae (MF) in dogs harboring resistant heartworm infections could be important in reducing the spread of heartworm resistance. The current study was conducted to investigate the potential for ProHeart® 6 (PH 6; Zoetis) and ProHeart® SR-12 (PH 12; Zoetis) to reduce MF in dogs experimentally inoculated with an isolate of D. immitis (ZoeMo-2012) confirmed to be resistant to MLs. Twenty-three dogs with preexisting heartworm infections (via surgical transplantation) were randomly allocated to four groups based on pretreatment (Day -14) MF counts. On Day 0, dogs received a subcutaneous injection of either saline (placebo-treated control, 6 dogs), PH 6 (0.17 mg/kg, 6 dogs), PH 12 (0.5 mg/kg, 5 dogs) or a single oral dose of moxidectin powder in a gelatin capsule (0.25 mg/kg, 6 dogs). All dogs were bled for MF counts (modified Knott's test) on Days 0 (pretreatment), 1, 3, 7, 14, 21, 28, 42, 56, and 84. Dogs in control and PH 6 groups were also bled for MF counts on Days 112, 140, and 168. No adverse events associated with treatment were observed for any dog. Average reductions in MF counts compared with controls for PH 6 were 9.7% on Day 1, increasing to 75.0% on Day 7, and further to 86.5% on Day 28. On Day 42, average MF reduction increased to 90.3%. Reductions increased further over the next several months with reductions of 91.3, 96.8, 96.6, and 98.9% on Days 56, 84, 112, and 140, respectively. On Day 168, the reduction was 99.3% (P < 0.0001). Average reductions in MF counts compared with controls for PH 12 were 20.9% on Day 1, increasing to 78.9% on Day 7, and further to 91.2% on Day 28. On Day 84, the reduction was 96.9%. For dogs receiving a single oral moxidectin (0.25 mg/kg) on Day 0, reductions in MF were 86.3% on Day 1 and fluctuated between 74.4 and 83.6% through Day 28. On Days 42 and 56, percentage reductions were 87.1 and 81.8%, respectively, and 92.6% at the final time point (Day 84). Both PH 6 and PH 12 were highly effective in reducing the MF levels of a confirmed ML-resistant heartworm isolate following a single dose.

  4. The effect of court location and available time on the tactical shot selection of elite squash players.

    PubMed

    Vučković, Goran; James, Nic; Hughes, Mike; Murray, Stafford; Sporiš, Goran; Perš, Janez

    2013-01-01

    No previous research in squash has considered the time between shots or the proximity of the ball to a wall, which are two important variables that influence shot outcomes. The aim of this paper was to analyse shot types to determine the extent to which they are played in different court areas and a more detailed analysis to determine whether the time available had an influence on the shot selected. Ten elite matches, contested by fifteen of the world's top right handed squash players (age 27 ± 3.2, height 1.81 ± 0.06 m, weight 76.3 ± 3.7 kg), at the men's World Team Championships were processed using the SAGIT/Squash tracking system with shot information manually added to the system. Results suggested that shot responses were dependent upon court location and the time between shots. When these factors were considered repeatable performance existed to the extent that one of two shots was typically played when there was limited time to play the shot (< 1.20s). For example, it was clear that when players did not have a lot of time to hit the ball (low time i.e. < 1.06s, and mid time i.e. 1.06 - 1.20s) in the front left corner close to the side wall, the crosscourt lob was used frequently (44.30% and 36.31% respectively) whereas when there was more time this shot was seldom used (13.64%). Consequently variant and invariant behaviour were shown to exist in elite squash although for the first time it was suggested that the availability of time to play a shot contributed to which of these behaviours was evident. This analysis could be extended by adopting a case study approach to see how individual differences in strategy and tactics affect shot selections. Key pointsPrevious research has suggested that a playing strategy, elements decided in advance of the match, may be evident for elite players by examining court location and preceding shot type, however these parameters alone are unlikely to be sufficient predictors.At present there is no known analysis in squash, or indeed in any of the racket sports, that has quantified the time available to respond to different shot types. An understanding of the time interval between shots and the movement characteristics of the player responding to different shots according to the court positions might facilitate a better understanding of the dynamics that determine shot selection.Some elements of a general playing strategy were evident e.g. predominately hitting to the back left of the court, but tactical differences in shot selection were also evident on the basis of court location and time available to play a shot.

  5. The Effect of Court Location and Available Time on the Tactical Shot Selection of Elite Squash Players

    PubMed Central

    Vučković, Goran; James, Nic; Hughes, Mike; Murray, Stafford; Sporiš, Goran; Perš, Janez

    2013-01-01

    No previous research in squash has considered the time between shots or the proximity of the ball to a wall, which are two important variables that influence shot outcomes. The aim of this paper was to analyse shot types to determine the extent to which they are played in different court areas and a more detailed analysis to determine whether the time available had an influence on the shot selected. Ten elite matches, contested by fifteen of the world’s top right handed squash players (age 27 ± 3.2, height 1.81 ± 0.06 m, weight 76.3 ± 3.7 kg), at the men’s World Team Championships were processed using the SAGIT/Squash tracking system with shot information manually added to the system. Results suggested that shot responses were dependent upon court location and the time between shots. When these factors were considered repeatable performance existed to the extent that one of two shots was typically played when there was limited time to play the shot (< 1.20s). For example, it was clear that when players did not have a lot of time to hit the ball (low time i.e. < 1.06s, and mid time i.e. 1.06 - 1.20s) in the front left corner close to the side wall, the crosscourt lob was used frequently (44.30% and 36.31% respectively) whereas when there was more time this shot was seldom used (13.64%). Consequently variant and invariant behaviour were shown to exist in elite squash although for the first time it was suggested that the availability of time to play a shot contributed to which of these behaviours was evident. This analysis could be extended by adopting a case study approach to see how individual differences in strategy and tactics affect shot selections. Key points Previous research has suggested that a playing strategy, elements decided in advance of the match, may be evident for elite players by examining court location and preceding shot type, however these parameters alone are unlikely to be sufficient predictors. At present there is no known analysis in squash, or indeed in any of the racket sports, that has quantified the time available to respond to different shot types. An understanding of the time interval between shots and the movement characteristics of the player responding to different shots according to the court positions might facilitate a better understanding of the dynamics that determine shot selection. Some elements of a general playing strategy were evident e.g. predominately hitting to the back left of the court, but tactical differences in shot selection were also evident on the basis of court location and time available to play a shot. PMID:24149727

  6. Lead in tissues of mallard ducks dosed with two types of lead shot

    USGS Publications Warehouse

    Finley, M.T.; Dieter, M.P.; Locke, L.N.

    1976-01-01

    Mallard ducks (Anas platyrhynchos) were sacrificed one month after ingesting one number 4 all-lead shot or one number 4 lead-iron shot. Livers, kidneys, blood, wingbones, and eggs were analyzed for lead by atomic absorption. Necropsy of sacrificed ducks failed to reveal any of the tissue lesions usually associated with lead poisoning in waterfowl. Lead levels in ducks given all-lead shot averaged about twice those in ducks given lead-iron shot, reflecting the amount of lead in the two types of shot. Lead in the blood of ducks dosed with all-lead shot averaged 0.64 ppm, and 0.28 ppm in ducks given lead-iron shot. Lead residues in livers and kidneys of females given all-lead shot were significantly higher than in males. In both dosed groups, lead levels in wingbones of females were about 10 times those in males, and were significantly correlated with the number of eggs laid after dosage. Lead levels in contents and shells of eggs laid by hens dosed with all-lead shot were about twice those in eggs laid by hens dosed with lead-iron shot. Eggshells were found to best reflect levels of lead in the blood. Our results indicate that mallards maintained on a balanced diet and dosed with one lead shot may not accumulate extremely high lead levels in the liver and kidney. However, extremely high lead deposition may result in the bone of laying hens after ingesting sublethal amounts of lead shot as a result of mobilization of calcium from the bone during eggshell formation.

  7. EVALUATION OF PROMPT DOSE ENVIRONMENT IN THE NATIONAL IGNITION FACILITY DURING D-D AND THD SHOTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khater, H; Dauffy, L; Sitaraman, S

    2009-04-28

    Evaluation of the prompt dose environment expected in the National Ignition Facility (NIF) during Deuterium-Deuterium (D-D) and Tritium-Hydrogen-Deuterium (THD) shots have been completed. D-D shots resulting in the production of an annual fusion yield of up to 2.4 kJ (200 shots with 10{sup 13} neutrons per shot) are considered. During the THD shot campaign, shots generating a total of 2 x 10{sup 14} neutrons per shot are also planned. Monte Carlo simulations have been performed to estimate prompt dose values inside the facility as well as at different locations outside the facility shield walls. The Target Chamber shielding, along withmore » Target Bay and Switchyard walls, roofs, and shield doors (when needed) will reduce dose levels in occupied areas to acceptable values during these shot campaigns. The calculated dose values inside occupied areas are small, estimated at 25 and 85 {micro}rem per shot during the D-D and THD shots, respectively. Dose values outside the facility are insignificant. The nearest building to the NIF facility where co-located workers may reside is at a distance of about 100 m from the Target Chamber Center (TCC). The dose in such a building is estimated at a fraction of a ?rem during a D-D or a THD shot. Dose at the nearest site boundary location (350 m from TCC), is caused by skyshine and to a lesser extent by direct radiation. The maximum off-site dose during any of the shots considered is less than 10 nano rem.« less

  8. Lead shot incidence on a New Mexico public hunting area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schranck, B.W.; Dollahon, G.R.

    The incidence of lead shot was investigated on a 20.2-ha (50-acre) seasonal marsh used for waterfowl hunting at the Bitter Lake National Wildlife Refuge, Roswell, New Mexico. Of the 162 soil samples taken randomly, 59% contained 1 to 5 lead shot. A minimum lead shot incidence of 98,985 shot per ha (40,075 per acre) was calculated. More shot was found in firm than in mucky soils. Management recommendations to limit waterfowl exposure to lead ingestion are offered.

  9. Comparison of the clinical efficacy of oral terbinafine and ketoconazole combined with cephalexin in the treatment of Malassezia dermatitis in dogs--a pilot study.

    PubMed

    Rosales, Millie S; Marsella, Rosanna; Kunkle, Gail; Harris, Bradley L; Nicklin, Constance F; Lopez, Jennifer

    2005-06-01

    The purpose of this randomized, single blinded clinical trial was to evaluate cytologically and clinically the efficacy of oral cephalexin alone and its combination with terbinafine or ketoconazole for the treatment of Malassezia dermatitis in dogs. Twenty-two client-owned dogs with Malassezia dermatitis completed the 3-week study. All received cephalexin (generic, 250 mg or 500 mg) at 22-30 mg kg(-1) twice daily. Eight dogs received terbinafine at 30 mg kg(-1) once daily and seven dogs received ketoconazole (generic, 200 mg) at 5-10 mg kg(-1) twice daily. The remaining seven dogs received cephalexin alone. At week 0 (visit 1) and week 3 (visit 2), mean yeast counts were determined from three affected areas using tape-strip cytology, a clinical index score (CIS) was assigned to the affected areas, and owners evaluated pruritus using a visual analogue scale. All groups showed reduction in mean yeast counts, CIS and pruritus. There was an 86.8%, 80.2% and 28.8% reduction in mean yeast counts from visit 1 to visit 2 for the terbinafine, ketoconazole and cephalexin-only groups, respectively. However, within treatment group comparisons a significant reduction in mean yeast count was only evident for the terbinafine (P < 0.002) and ketoconazole (P < 0.01) groups. Pruritus reduction was only significant for the terbinafine group. These preliminary results suggest that terbinafine should be further assessed for the treatment of canine Malassezia dermatitis.

  10. Evaluation of effect of topical ozone therapy on salivary Candidal carriage in oral candidiasis.

    PubMed

    Khatri, Isha; Moger, Ganapathi; Kumar, N Anil

    2015-01-01

    Ozone is highly valued for various therapeutic applications such as antimicrobial, antihypoxic, analgesic, and immunostimulating for more than a century in the medical profession. Ozone therapy is now gaining a strong foothold in dentistry. Ozone has bactericidal, fungicidal, and virucidal properties. Oral candidiasis is one of the most common opportunistic fungal infections of the oral cavity. Hence, a study was conducted to evaluate and compare the ability of ozonated water and topical clotrimazole in reducing the Candidal species colony-forming unit (CFU) count in oral candidiasis. The study included 40 candidiasis patients of either sex aged between 18 and 60 years attending the Department of Oral Medicine and Radiology. The patients were randomly assigned to either topical ozone therapy or topical clotrimazole groups. Salivary Candidal CFU counts were assessed during and after the treatments. There was gradual but significant reduction in Candidal CFU count in both groups. At the end of the treatment, Candidal CFU count reduction in ozone group (60.5% reduction) was more than the clotrimazole group (32.3% reduction). 14 patients (70%) with candidiasis in ozone group were reduced to 6 (30%) whereas only 8 patients (40%) out of 13 (65%) in clotrimazole group, although intergroup comparison was not statistically significant. Ozone therapy was much more effective in reducing the patients with candidiasis to a state of carriers. These findings suggest that ozonated water might be useful to treat oral candidiasis.

  11. Semantic Shot Classification in Sports Video

    NASA Astrophysics Data System (ADS)

    Duan, Ling-Yu; Xu, Min; Tian, Qi

    2003-01-01

    In this paper, we present a unified framework for semantic shot classification in sports videos. Unlike previous approaches, which focus on clustering by aggregating shots with similar low-level features, the proposed scheme makes use of domain knowledge of a specific sport to perform a top-down video shot classification, including identification of video shot classes for each sport, and supervised learning and classification of the given sports video with low-level and middle-level features extracted from the sports video. It is observed that for each sport we can predefine a small number of semantic shot classes, about 5~10, which covers 90~95% of sports broadcasting video. With the supervised learning method, we can map the low-level features to middle-level semantic video shot attributes such as dominant object motion (a player), camera motion patterns, and court shape, etc. On the basis of the appropriate fusion of those middle-level shot classes, we classify video shots into the predefined video shot classes, each of which has a clear semantic meaning. The proposed method has been tested over 4 types of sports videos: tennis, basketball, volleyball and soccer. Good classification accuracy of 85~95% has been achieved. With correctly classified sports video shots, further structural and temporal analysis, such as event detection, video skimming, table of content, etc, will be greatly facilitated.

  12. Self-Paced and Temporally Constrained Throwing Performance by Team-Handball Experts and Novices without Foreknowledge of Target Position

    PubMed Central

    Rousanoglou, Elissavet N.; Noutsos, Konstantinos S.; Bayios, Ioannis A.; Boudolos, Konstantinos D.

    2015-01-01

    The fixed duration of a team-handball game and its continuously changing situations incorporate an inherent temporal pressure. Also, the target’s position is not foreknown but online determined by the player’s interceptive processing of visual information. These ecological limitations do not favour throwing performance, particularly in novice players, and are not reflected in previous experimental settings of self-paced throws with foreknowledge of target position. The study investigated the self-paced and temporally constrained throwing performance without foreknowledge of target position, in team-handball experts and novices in three shot types (Standing Shot, 3Step Shot, Jump Shot). The target position was randomly illuminated on a tabloid surface before (self-paced condition) and after (temporally constrained condition) shot initiation. Response time, throwing velocity and throwing accuracy were measured. A mixed 2 (experience) X 2 (temporal constraint condition) ANOVA was applied. The novices performed with significantly lower throwing velocity and worse throwing accuracy in all shot types (p = 0.000) and, longer response time only in the 3Step Shot (p = 0.013). The temporal constraint (significantly shorter response times in all shot types at p = 0.000) had a shot specific effect with lower throwing velocity only in the 3Step Shot (p = 0.001) and an unexpected greater throwing accuracy only in the Standing Shot (p = 0.002). The significant interaction between experience and temporal constraint condition in throwing accuracy (p = 0.003) revealed a significant temporal constraint effect in the novices (p = 0.002) but not in the experts (p = 0.798). The main findings of the study are the shot specificity of the temporal constraint effect, as well as that, depending on the shot, the novices’ throwing accuracy may benefit rather than worsen under temporal pressure. Key points The temporal constraint induced a shot specific significant difference in throwing velocity in both the experts and the novices. The temporal constraint induced a shot specific significant difference in throwing accuracy only in the novices. Depending on the shot demands, the throwing accuracy of the novices may benefit under temporally constrained situations. PMID:25729288

  13. Short Shot Tower for Silicon

    NASA Technical Reports Server (NTRS)

    Bates, H. E.; Hill, D. M.; Jewett, D. N.

    1983-01-01

    Drop length necessary to convert molten silicon to shot reduced by proposed new process. Conversion of silicon from powder or chunks to shot often simplifies processing. Shot is more easily handled in most processing equipment. Drops of liquid silicon fall through protective cloud of argon, then through rapidly cooling bath of methanol, where they quickly turn into solid shot.

  14. Effectiveness of Polyvalent Bacterial Lysate and Autovaccines Against Upper Respiratory Tract Bacterial Colonization by Potential Pathogens: A Randomized Study

    PubMed Central

    Zagólski, Olaf; Stręk, Paweł; Kasprowicz, Andrzej; Białecka, Anna

    2015-01-01

    Background Polyvalent bacterial lysate (PBL) is an oral immunostimulating vaccine consisting of bacterial standardized lysates obtained by lysis of different strains of bacteria. Autovaccines are individually prepared based on the results of smears obtained from the patient. Both types of vaccine can be used to treat an ongoing chronic infection. This study sought to determine which method is more effective against nasal colonization by potential respiratory tract pathogens. Material/Methods We enrolled 150 patients with aerobic Gram stain culture and count results indicating bacterial colonization of the nose and/or throat by potential pathogens. The participants were randomly assigned to each of the following groups: 1. administration of PBL, 2. administration of autovaccine, and 3. no intervention (controls). Results Reduction of the bacterial count in Streptococcus pneumoniae-colonized participants was significant after the autovaccine (p<0.001) and PBL (p<0.01). Reduction of the bacterial count of other β-hemolytic streptococcal strains after treatment with the autovaccine was significant (p<0.01) and was non-significant after PBL. In Haemophilus influenzae colonization, significant reduction in the bacterial count was noted in the PBL group (p<0.01). Methicillin-resistant Staphylococcus aureus colonization did not respond to either treatment. Conclusions The autovaccine is more effective than PBL for reducing bacterial count of Streptococcus pneumoniae and β-hemolytic streptococci, while PBL was more effective against Haemophilus influenzae colonization. PMID:26434686

  15. Mold and aflatoxin reduction by gamma radiation of packed hot peppers and their evolution during storage.

    PubMed

    Iqbal, Qumer; Amjad, Muhammad; Asi, Muhammad Rafique; Ariño, Agustin

    2012-08-01

    The effect of gamma radiation on moisture content, total mold counts, Aspergillus counts, and aflatoxins of three hot pepper hybrids (Sky Red, Maha, and Wonder King) was investigated. Whole dried peppers packed in polyethylene bags were gamma irradiated at 0 (control), 2, 4, and 6 kGy and stored at 25°C for 90 days. Gamma radiation proved to be effective in reducing total mold and Aspergillus counts in a dose-dependent relationship. Total mold counts in irradiated peppers immediately after treatments were significantly lowered compared with those in nonirradiated samples, achieving 90 and 99% reduction at 2- and 4-kGy doses, respectively. Aspergillus counts were significantly reduced, by 93 and 97%, immediately after irradiation at doses of 2 and 4 kGy, respectively. A radiation dose of 6 kGy completely eliminated the population of total molds and Aspergillus fungi. The evolution of total molds in control and irradiated samples indicated no further fungal proliferation during 3 months of storage at 25°C. Aflatoxin levels were slightly affected by radiation doses of 2 and 4 kGy and showed a nonsignificant reduction of 6% at the highest radiation dose of 6 kGy. The distinct effectiveness of gamma radiation in molds and aflatoxins can be explained by the target theory of food irradiation, which states that the likelihood of a microorganism or a molecule being inactivated by gamma rays increases as its size increases.

  16. Hepatitis B

    MedlinePlus

    ... 12 hours after birth, followed by a second shot 1 month later, and the third shot 5 months ... the hepatitis B virus should get the first shot within 1 to 2 months after birth, the second shot ...

  17. On the residual stress modeling of shot-peened AISI 4340 steel: finite element and response surface methods

    NASA Astrophysics Data System (ADS)

    Asgari, Ali; Dehestani, Pouya; Poruraminaie, Iman

    2018-02-01

    Shot peening is a well-known process in applying the residual stress on the surface of industrial parts. The induced residual stress improves fatigue life. In this study, the effects of shot peening parameters such as shot diameter, shot speed, friction coefficient, and the number of impacts on the applied residual stress will be evaluated. To assess these parameters effect, firstly the shot peening process has been simulated by finite element method. Then, effects of the process parameters on the residual stress have been evaluated by response surface method as a statistical approach. Finally, a strong model is presented to predict the maximum residual stress induced by shot peening process in AISI 4340 steel. Also, the optimum parameters for the maximum residual stress are achieved. The results indicate that effect of shot diameter on the induced residual stress is increased by increasing the shot speed. Also, enhancing the friction coefficient magnitude always cannot lead to increase in the residual stress.

  18. 100-kHz shot-to-shot broadband data acquisition for high-repetition-rate pump-probe spectroscopy.

    PubMed

    Kanal, Florian; Keiber, Sabine; Eck, Reiner; Brixner, Tobias

    2014-07-14

    Shot-to-shot broadband detection is common in ultrafast pump-probe spectroscopy. Taking advantage of the intensity correlation of subsequent laser pulses improves the signal-to-noise ratio. Finite data readout times of CCD chips in the employed spectrometer and the maximum available speed of mechanical pump-beam choppers typically limit this approach to lasers with repetition rates of a few kHz. For high-repetition (≥ 100 kHz) systems, one typically averages over a larger number of laser shots leading to inferior signal-to-noise ratios or longer measurement times. Here we demonstrate broadband shot-to-shot detection in transient absorption spectroscopy with a 100-kHz femtosecond laser system. This is made possible using a home-built high-speed chopper with external laser synchronization and a fast CCD line camera. Shot-to-shot detection can reduce the data acquisition time by two orders of magnitude compared to few-kHz lasers while keeping the same signal-to-noise ratio.

  19. Clinical and MRI activity as determinants of sample size for pediatric multiple sclerosis trials

    PubMed Central

    Verhey, Leonard H.; Signori, Alessio; Arnold, Douglas L.; Bar-Or, Amit; Sadovnick, A. Dessa; Marrie, Ruth Ann; Banwell, Brenda

    2013-01-01

    Objective: To estimate sample sizes for pediatric multiple sclerosis (MS) trials using new T2 lesion count, annualized relapse rate (ARR), and time to first relapse (TTFR) endpoints. Methods: Poisson and negative binomial models were fit to new T2 lesion and relapse count data, and negative binomial time-to-event and exponential models were fit to TTFR data of 42 children with MS enrolled in a national prospective cohort study. Simulations were performed by resampling from the best-fitting model of new T2 lesion count, number of relapses, or TTFR, under various assumptions of the effect size, trial duration, and model parameters. Results: Assuming a 50% reduction in new T2 lesions over 6 months, 90 patients/arm are required, whereas 165 patients/arm are required for a 40% treatment effect. Sample sizes for 2-year trials using relapse-related endpoints are lower than that for 1-year trials. For 2-year trials and a conservative assumption of overdispersion (ϑ), sample sizes range from 70 patients/arm (using ARR) to 105 patients/arm (TTFR) for a 50% reduction in relapses, and 230 patients/arm (ARR) to 365 patients/arm (TTFR) for a 30% relapse reduction. Assuming a less conservative ϑ, 2-year trials using ARR require 45 patients/arm (60 patients/arm for TTFR) for a 50% reduction in relapses and 145 patients/arm (200 patients/arm for TTFR) for a 30% reduction. Conclusion: Six-month phase II trials using new T2 lesion count as an endpoint are feasible in the pediatric MS population; however, trials powered on ARR or TTFR will need to be 2 years in duration and will require multicentered collaboration. PMID:23966255

  20. Comparison of athlete-coach perceptions of internal and external load markers for elite junior tennis training.

    PubMed

    Murphy, Alistair P; Duffield, Rob; Kellett, Aaron; Reid, Machar

    2014-09-01

    To investigate the discrepancy between coach and athlete perceptions of internal load and notational analysis of external load in elite junior tennis. Fourteen elite junior tennis players and 6 international coaches were recruited. Ratings of perceived exertion (RPEs) were recorded for individual drills and whole sessions, along with a rating of mental exertion, coach rating of intended session exertion, and athlete heart rate (HR). Furthermore, total stroke count and unforced-error count were notated using video coding after each session, alongside coach and athlete estimations of shots and errors made. Finally, regression analyses explained the variance in the criterion variables of athlete and coach RPE. Repeated-measures analyses of variance and interclass correlation coefficients revealed that coaches significantly (P < .01) underestimated athlete session RPE, with only moderate correlation (r = .59) demonstrated between coach and athlete. However, athlete drill RPE (P = .14; r = .71) and mental exertion (P = .44; r = .68) were comparable and substantially correlated. No significant differences in estimated stroke count were evident between athlete and coach (P = .21), athlete notational analysis (P = .06), or coach notational analysis (P = .49). Coaches estimated significantly greater unforced errors than either athletes or notational analysis (P < .01). Regression analyses found that 54.5% of variance in coach RPE was explained by intended session exertion and coach drill RPE, while drill RPE and peak HR explained 45.3% of the variance in athlete session RPE. Coaches misinterpreted session RPE but not drill RPE, while inaccurately monitoring error counts. Improved understanding of external- and internal-load monitoring may help coach-athlete relationships in individual sports like tennis avoid maladaptive training.

  1. Bladder irrigation in patients with indwelling catheters.

    PubMed

    Bruun, J N; Digranes, A

    1978-01-01

    The effect of intermittent bladder irrigation on the bacterial counts in urine samples was studied in patients with indwelling catheter and pre-existing urinary tract infection. Four different irrigating solutions were used. Irrigation with saline or 0.25% acetic acid had no effect on the urinary bacterial count. The bacterial counts were effectively reduced during intermittent irrigation both with 0.02% chlorhexidine and with 0.25% silver nitrate. Silver nitrate gave the greatest reduction of bacterial counts but chlorhexidine is preferable due to fewer side effects and greater convenience.

  2. Single-shot measurement of >1010 pulse contrast for ultra-high peak-power lasers

    PubMed Central

    Wang, Yongzhi; Ma, Jingui; Wang, Jing; Yuan, Peng; Xie, Guoqiang; Ge, Xulei; Liu, Feng; Yuan, Xiaohui; Zhu, Heyuan; Qian, Liejia

    2014-01-01

    Real-time pulse-contrast observation with a high dynamic range is a prerequisite to tackle the contrast challenge in ultra-high peak-power lasers. However, the commonly used delay-scanning cross-correlator (DSCC) can only provide the time-consumed measurements for repetitive lasers. Single-shot cross-correlator (SSCC) becomes essential in optimizing laser systems and exploring contrast mechanisms. Here we report our progress in developing SSCC towards its practical use. By integrating both the techniques of scattering-noise reduction and sensitive parallel detection into SSCC, we demonstrate a high dynamic range of >1010, which, to our best knowledge, is the first demonstration of an SSCC with a dynamic range comparable to that of commercial DSCCs. The comparison of high-dynamic measurement performances between SSCC and a standard DSCC (Sequoia, Amplitude Technologies) is also carried out on a 200 TW Ti:sapphire laser, and the consistency of results verifies the veracity of our SSCC. PMID:24448655

  3. Optically-sectioned two-shot structured illumination microscopy with Hilbert-Huang processing.

    PubMed

    Patorski, Krzysztof; Trusiak, Maciej; Tkaczyk, Tomasz

    2014-04-21

    We introduce a fast, simple, adaptive and experimentally robust method for reconstructing background-rejected optically-sectioned images using two-shot structured illumination microscopy. Our innovative data demodulation method needs two grid-illumination images mutually phase shifted by π (half a grid period) but precise phase displacement between two frames is not required. Upon frames subtraction the input pattern with increased grid modulation is obtained. The first demodulation stage comprises two-dimensional data processing based on the empirical mode decomposition for the object spatial frequency selection (noise reduction and bias term removal). The second stage consists in calculating high contrast image using the two-dimensional spiral Hilbert transform. Our algorithm effectiveness is compared with the results calculated for the same input data using structured-illumination (SIM) and HiLo microscopy methods. The input data were collected for studying highly scattering tissue samples in reflectance mode. Results of our approach compare very favorably with SIM and HiLo techniques.

  4. A Ballistics Examination of Firearm Injuries Involving Breast Implants.

    PubMed

    Pannucci, Christopher J; Cyr, Adam J; Moores, Neal G; Young, Jason B; Szegedi, Martin

    2018-03-01

    This ballistics study examines whether saline breast implants can decrease tissue penetration in firearm injuries. We hypothesize that the fluid column within a saline breast implant can alter bullet velocity and/or bullet pattern of mushrooming. The two experimental groups included saline implants with 7.4 cm projection and a no implant group. The experimental design allowed the bullet to pass-through an implant and into ballistics gel (n = 10) or into ballistics gel without passage through an implant (n = 11). Shots that passed through an implant had 20.6% decreased penetration distance when compared to shots that did not pass-through an implant; this difference was statistically significant (31.9 cm vs. 40.2 cm, p < 0.001). Implant group bullets mushroomed prior to gel entry, but the no implant group mushroomed within the gel. Bullet passage through a saline breast implant results in direct bullet velocity reduction and earlier bullet mushrooming; this causes significantly decreased ballistics gel penetration. © 2017 American Academy of Forensic Sciences.

  5. Single shot speckle and coherence analysis of the hard X-ray free electron laser LCLS

    DOE PAGES

    Lee, Sooheyong; Roseker, W.; Gutt, C.; ...

    2013-10-08

    The single shot based coherence properties of hard x-ray pulses from the Linac Coherent Light Source (LCLS) were measured by analyzing coherent diffraction patterns from nano-particles and gold nanopowder. The intensity histogram of the small angle x-ray scattering ring from nano-particles reveals the fully transversely coherent nature of the LCLS beam with a number of transverse modemore » $$\\langle$$M s$$\\rangle$$ = 1.1. On the other hand, the speckle contrasts measured at a large wavevector yields information about the longitudinal coherence of the LCLS radiation after a silicon (111) monochromator. The quantitative agreement between our data and the simulation confirms a mean coherence time of 2.2 fs and a x-ray pulse duration of 29 fs. Lastly the observed reduction of the speckle contrast generated by x-rays with pulse duration longer than 30 fs indicates ultrafast dynamics taking place at an atomic length scale prior to the permanent sample damage.« less

  6. Benchmarking Non-Hardware Balance-of-System (Soft) Costs for U.S. Photovoltaic Systems, Using a Bottom-Up Approach and Installer Survey - Second Edition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedman, B.; Ardani, K.; Feldman, D.

    2013-10-01

    This report presents results from the second U.S. Department of Energy (DOE) sponsored, bottom-up data-collection and analysis of non-hardware balance-of-system costs -- often referred to as 'business process' or 'soft' costs -- for U.S. residential and commercial photovoltaic (PV) systems. In service to DOE's SunShot Initiative, annual expenditure and labor-hour-productivity data are analyzed to benchmark 2012 soft costs related to (1) customer acquisition and system design (2) permitting, inspection, and interconnection (PII). We also include an in-depth analysis of costs related to financing, overhead, and profit. Soft costs are both a major challenge and a major opportunity for reducing PVmore » system prices and stimulating SunShot-level PV deployment in the United States. The data and analysis in this series of benchmarking reports are a step toward the more detailed understanding of PV soft costs required to track and accelerate these price reductions.« less

  7. Jello shot consumption among older adolescents: a pilot study of a newly identified public health problem.

    PubMed

    Binakonsky, Jane; Giga, Noreen; Ross, Craig; Siegel, Michael

    2011-01-01

    We investigated the extent of jello shot consumption among underage youths. We conducted a pilot study among a nonrandom national sample of 108 drinkers, aged 16-20 years, recruited from the Knowledge Networks Internet panel in 2010 by using consecutive sampling. The prevalence of past 30-day jello shot consumption among the 108 drinkers, aged 16-20 years, in our sample was 21.4%, and among those who consumed jello shots, the percentage of alcohol consumption attributable to jello shots averaged 14.5%. We concluded that jello shot use is prevalent among youths, representing a substantial proportion of their alcohol intake. Surveillance of youth alcohol use should include jello shot consumption.

  8. 78 FR 78275 - Migratory Bird Hunting; Revision of Language for Approval of Nontoxic Shot for Use in Waterfowl...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-26

    ... product from one small source (e.g., ``HOT SHOT'' device from Stream Systems) when metal detection... of complete erosion and absorption of one shot or coated shot in a 24-hour period. Define the nature... Approval of Nontoxic Shot for Use in Waterfowl Hunting AGENCY: Fish and Wildlife Service, Interior. ACTION...

  9. Effect of antimicrobial photodynamic therapy on the counts of salivary Streptococcus mutans in children with severe early childhood caries.

    PubMed

    Fekrazad, Reza; Seraj, Bahman; Chiniforush, Nasim; Rokouei, Mehrak; Mousavi, Niloofar; Ghadimi, Sara

    2017-06-01

    Antimicrobial photodynamic therapy (aPDT) is a novel technique for reduction of pathogenic microorganisms in dentistry. The aim of this study was to evaluate the effects of aPDT on Streptococcus mutans reduction in children with severe early childhood caries. Twenty-two children with severe early childhood caries aged 3-6 years were treated with toluoidine blue O (TBO) for 1min and irradiated by a Light Emitting Diode (LED; FotoSan, CMS Dental, Denmark) with the exposure time of 150s. Saliva samples were collected at baseline, 1h and 7 days after treatment. S. mutans counts were determined using the Dentocult SM Strip mutans. The counts of S. mutans in saliva decreased significantly after 1h (P<0.001). However, the difference in reduction of S. mutans counts in saliva was not significant between the baseline and 7 days after treatment (P>0.05). aPDT seems to be efficient to reduce salivary S. mutans immediately after treatment in children with severe early childhood caries. However, further research is needed to evaluate different doses and frequency of irradiation in combination with restoring carious teeth to find more durable results. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Hepatitis A and the Vaccine (Shot) to Prevent It

    MedlinePlus

    ... Resources Maternal Immunization Resources Related Links Vaccines & Immunizations Hepatitis A and the Vaccine (Shot) to Prevent It ... the vaccine. Why should my child get the hepatitis A shot? The hepatitis A shot: Protects your ...

  11. An Invitation to Imitation

    DTIC Science & Technology

    2015-03-15

    Super Mario Bros, 2010b. URL http://www.youtube.com/watch?v=anOI0xZ3kGM. S. Ross and J. A. Bagnell. Efficient reductions for imitation learning. In...learning to drive a car in a video game by performing a direct mapping from screen shots to steering angles. Figure 4 illustrates the classic super - an...same distribution and thus the super - vised learning assumption of independent and identically distributed (i.i.d.) data is badly violated. A natural

  12. OPERATION DOMINIC, SHOT SWORD FISH. Project Officer’s Report. Project 1. 1. Underwater Pressures

    DTIC Science & Technology

    1985-09-01

    LEVEL ACCESSION FOR NT1S GRAfcl DTK TAB UNANNOUNCED JUSTIFICATION D D BY DISTRIBUTION / AVAILABILrTY CODES DIST AW AVAIL AND/OR SPECIAL...The batteries ueed to power the recorderi were composed of new nickel-cadnlum cells with the ssse capacity rating as those used during Hardtack...the better cell quality and approximately 35-percent reduction in power requirements. A new battery-charging circuit of Increased convenience and

  13. Availability of Care Concordant With Patient-centered Medical Home Principles Among Those With Chronic Conditions: Measuring Care Outcomes.

    PubMed

    Pourat, Nadereh; Charles, Shana A; Snyder, Sophie

    2016-03-01

    Care delivery redesign in the form of patient-centered medical home (PCMH) is considered as a potential solution to improve patient outcomes and reduce costs, particularly for patients with chronic conditions. But studies of prevalence or impact at the population level are rare. We aimed to assess whether desired outcomes indicating better care delivery and patient-centeredness were associated with receipt of care according to 3 important PCMH principles. We analyzed data from a representative population survey in California in 2009, focusing on a population with chronic condition who had a usual source of care. We used bivariate, logistic, and negative-binomial regressions. The indicators of PCMH concordant care included continuity of care (personal doctor), care coordination, and care management (individual treatment plan). Outcomes included flu shots, count of outpatient visits, any emergency department visit, timely provider communication, and confidence in self-care. We found that patients whose care was concordant with all 3 PCMH principles were more likely to receive flu shots, more outpatient care, and timely response from providers. Concordance with 2 principles led to some desired outcomes. Concordance with only 1 principle was not associated with desired outcomes. Patients who received care that met 3 key aspects of PCMH: coordination, continuity, and management, had better quality of care and more efficient use of the health care system.

  14. A comparison of transcatheter arterial embolization with one shot therapy for the patients with hepatic cell carcinoma.

    PubMed

    Monna, T; Kanno, T; Marumo, T; Harihara, S; Kuroki, T; Yamamoto, S; Kobayashi, N; Sato, M; Nakamura, K; Nakatsuka, H; Onoyama, Y; Yamada, R

    1982-12-01

    It has been confirmed gradually that transcatheter arterial embolization is the most effective, conservative therapy for the treatment of unresectable hepatic cell carcinoma (hepatoma). Embolization or one shot therapy was carried out in a clinical trial involving 41 patients with unresectable hepatoma visiting our department. Embolization group (emboli G): 19 cases. 1 to 6 embolizations in each case. One shot group (one shot G): 22 cases. Medications: Mitomycin C 10-40 mg and others. Disappearance rate of icterus after treatment was 50% (emboli G) and 25% (one shot G). Decrease in size of hepatomegaly or tumor was seen in 84% (emboli G) and 32% (one shot G) which was statistically significant (less than 1%). Serum AFP titer after embolization decreased in all cases but in only 5 of 12 cases (ca 41%) after one shot (less than 1%). Effective cases measured by Karnofsky's method were 18 out of 19 cases (95%) in emboli G, but in one shot G only 10 out of 22 cases (ca 45%)(less than 0.1%). Survival rate after each therapy was 67% (emboli G) and 38% (one shot G) after 6 months, and 59% (emboli G) and 19% (one shot G) at 1 year respectively. One study showed that transcatheter arterial embolization therapy was much more effective than one shot therapy.

  15. Effect of shot peening on the microstructure of laser hardened 17-4PH

    NASA Astrophysics Data System (ADS)

    Wang, Zhou; Jiang, Chuanhai; Gan, Xiaoyan; Chen, Yanhua

    2010-12-01

    In order to investigate the influence of shot peening on microstructure of laser hardened steel and clarify how much influence of initial microstructure induced by laser hardening treatment on final microstructure of laser hardened steel after shot peening treatment, measurements of retained austenite, measurements of microhardness and microstructural analysis were carried out on three typical areas including laser hardened area, transitional area and matrix area of laser hardened 17-4PH steel. The results showed that shot peening was an efficient cold working method to eliminate the retained austenite on the surface of laser hardened samples. The surface hardness increased dramatically when shot peening treatments were carried out. The analyses of microstructure of laser hardened 17-4PH after shot peening treatment were carried out in matrix area and laser hardened area via Voigt method. With the increasing peening intensity, the influence depth of shot peening on hardness and microstructure increased but the surface hardness and microstructure did not change when certain peening intensity was reached. Influence depth of shot peening on hardness was larger than influence depth of shot peening on microstructure due to the kinetic energy loss along the depth during shot peening treatment. From the microstructural result, it can be shown that the shot peening treatment can influence the domain size and microstrain of treated samples but laser hardening treatment can only influence the microstrain of treated samples.

  16. Efficacy of tigecycline alone and in combination with gentamicin in the treatment of experimental endocarditis due to linezolid-resistant Enterococcus faecium.

    PubMed

    Pontikis, Konstantinos; Pefanis, Angelos; Tsaganos, Thomas; Tzepi, Ira-Maria; Carrer, Dionyssia-Pinelopi; Giamarellou, Helen

    2013-07-01

    We evaluated the efficacy of tigecycline in a rabbit model of experimental endocarditis caused by a linezolid-resistant clinical strain of Enterococcus faecium. Tigecycline-treated animals had a 2.8-log10-CFU/g reduction in microbial counts in excised vegetations compared with controls. Addition of gentamicin caused a further arithmetical reduction in colony counts. The therapeutic effect was sustained 5 days after completion of treatment, as shown by relapse studies performed in treatment groups.

  17. Efficacy of Tigecycline Alone and in Combination with Gentamicin in the Treatment of Experimental Endocarditis Due to Linezolid-Resistant Enterococcus faecium

    PubMed Central

    Pefanis, Angelos; Tsaganos, Thomas; Tzepi, Ira-Maria; Carrer, Dionyssia-Pinelopi; Giamarellou, Helen

    2013-01-01

    We evaluated the efficacy of tigecycline in a rabbit model of experimental endocarditis caused by a linezolid-resistant clinical strain of Enterococcus faecium. Tigecycline-treated animals had a 2.8-log10-CFU/g reduction in microbial counts in excised vegetations compared with controls. Addition of gentamicin caused a further arithmetical reduction in colony counts. The therapeutic effect was sustained 5 days after completion of treatment, as shown by relapse studies performed in treatment groups. PMID:23587961

  18. Noise models for low counting rate coherent diffraction imaging.

    PubMed

    Godard, Pierre; Allain, Marc; Chamard, Virginie; Rodenburg, John

    2012-11-05

    Coherent diffraction imaging (CDI) is a lens-less microscopy method that extracts the complex-valued exit field from intensity measurements alone. It is of particular importance for microscopy imaging with diffraction set-ups where high quality lenses are not available. The inversion scheme allowing the phase retrieval is based on the use of an iterative algorithm. In this work, we address the question of the choice of the iterative process in the case of data corrupted by photon or electron shot noise. Several noise models are presented and further used within two inversion strategies, the ordered subset and the scaled gradient. Based on analytical and numerical analysis together with Monte-Carlo studies, we show that any physical interpretations drawn from a CDI iterative technique require a detailed understanding of the relationship between the noise model and the used inversion method. We observe that iterative algorithms often assume implicitly a noise model. For low counting rates, each noise model behaves differently. Moreover, the used optimization strategy introduces its own artefacts. Based on this analysis, we develop a hybrid strategy which works efficiently in the absence of an informed initial guess. Our work emphasises issues which should be considered carefully when inverting experimental data.

  19. Jello Shot Consumption among Older Adolescents: A Pilot Study of a Newly Identified Public Health Problem

    PubMed Central

    Binakonsky, Jane; Giga, Noreen; Ross, Craig; Siegel, Michael

    2011-01-01

    We investigated the extent of jello shot consumption among underage youth. We conducted a pilot study among a non-random national sample of 108 drinkers, ages 16-20 years, recruited from the Knowledge Networks internet panel in 2010 using consecutive sampling. The prevalence of past 30-day jello shot consumption among the 108 16-20 year-old drinkers in our sample was 21.4% and among those who consumed jello shots, the percentage of alcohol consumption attributable to jello shots averaged 14.5%. We conclude that jello shot use is prevalent among youth, representing a substantial proportion of their alcohol intake. Surveillance of youth alcohol use should include jello shot consumption. PMID:21174500

  20. Comparison of optimization algorithms for the slow shot phase in HPDC

    NASA Astrophysics Data System (ADS)

    Frings, Markus; Berkels, Benjamin; Behr, Marek; Elgeti, Stefanie

    2018-05-01

    High-pressure die casting (HPDC) is a popular manufacturing process for aluminum processing. The slow shot phase in HPDC is the first phase of this process. During this phase, the molten metal is pushed towards the cavity under moderate plunger movement. The so-called shot curve describes this plunger movement. A good design of the shot curve is important to produce high-quality cast parts. Three partially competing process goals characterize the slow shot phase: (1) reducing air entrapment, (2) avoiding temperature loss, and (3) minimizing oxide caused by the air-aluminum contact. Due to the rough process conditions with high pressure and temperature, it is hard to design the shot curve experimentally. There exist a few design rules that are based on theoretical considerations. Nevertheless, the quality of the shot curve design still depends on the experience of the machine operator. To improve the shot curve it seems to be natural to use numerical optimization. This work compares different optimization strategies for the slow shot phase optimization. The aim is to find the best optimization approach on a simple test problem.

  1. The spectraplakin Short stop is an essential microtubule regulator involved in epithelial closure in Drosophila

    PubMed Central

    Takács, Zsanett; Vilmos, Péter; Lénárt, Péter; Röper, Katja; Erdélyi, Miklós

    2017-01-01

    ABSTRACT Dorsal closure of the Drosophila embryonic epithelium provides an excellent model system for the in vivo analysis of molecular mechanisms regulating cytoskeletal rearrangements. In this study, we investigated the function of the Drosophila spectraplakin Short stop (Shot), a conserved cytoskeletal structural protein, during closure of the dorsal embryonic epithelium. We show that Shot is essential for the efficient final zippering of the opposing epithelial margins. By using isoform-specific mutant alleles and genetic rescue experiments with truncated Shot variants, we demonstrate that Shot functions as an actin–microtubule cross-linker in mediating zippering. At the leading edge of epithelial cells, Shot regulates protrusion dynamics by promoting filopodia formation. Fluorescence recovery after photobleaching (FRAP) analysis and in vivo imaging of microtubule growth revealed that Shot stabilizes dynamic microtubules. The actin- and microtubule-binding activities of Shot are simultaneously required in the same molecule, indicating that Shot is engaged as a physical crosslinker in this process. We propose that Shot-mediated interactions between microtubules and actin filaments facilitate filopodia formation, which promotes zippering by initiating contact between opposing epithelial cells. PMID:28062848

  2. Birth Control Shot

    MedlinePlus

    ... Safe Videos for Educators Search English Español Birth Control Shot KidsHealth / For Teens / Birth Control Shot What's in this article? What Is It? ... La inyección anticonceptiva What Is It? The birth control shot is a long-acting form of progesterone, ...

  3. Histopathology of mallards dosed with lead and selected substitute shot

    USGS Publications Warehouse

    Locke, L.N.; Irby, H.D.; Bagley, George E.

    1967-01-01

    The histopathological response of male game farm mallards fed lead, three types of plastic-coated lead, two lead-magnesium alloys, iron, copper, zinc-coated iron, and molybdenum-coated iron shot was studied. Mallards fed lead, plastic-coated lead, or lead-magnesium alloy shot developed a similar pathological response, including the formation of acid-fast intranuclear inclusion bodies in the kidneys. Birds fed iron or molybdenum-coated iron shot developed hemosiderosis of the liver. Two of four mallards fed zinc-coated iron shot also developed hemosiderosis of the liver. No lesions were found in mallards fed copper shot.

  4. Duration of mentally simulated movement before and after a golf shot.

    PubMed

    Koyama, Satoshi; Tsuruhara, Kiyoshi; Yamamoto, Yuji

    2009-02-01

    This report examined the temporal consistency of preshot routines and the temporal similarity and variability between simulated movements before and after a shot. 12 male amateur golfers ages 32 to 69 years (M=53.4, SD=10.5) were assigned into two groups according to their handicaps: skilled (M=4.0 handicap, SD=3.1) and less-skilled (M=16.0 handicap, SD=6.5). They performed their shots mentally from their preshot routines to the points when the balls came to rest, then performed the same shots physically and again recalled the shots mentally. For each of four par-three holes, participants' performances were filmed, and the durations of mental and actual shots were timed. Analysis showed that the skilled golfers had more consistent preshot routines in actual movement, and they also had longer durations for the ball flight phase than the less-skilled golfers in simulated movement. The present findings support the importance of consistent preshot routines for high performance in golf, however, the duration of simulated movements was underestimated both before and after the shots. This also suggests that skilled golfers attend to performance goals both before and after shots to execute their shots under proceduralized control and to correct their movements for their next shot.

  5. 45 CFR 261.42 - Which reductions count in determining the caseload reduction credit?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... AND HUMAN SERVICES ENSURING THAT RECIPIENTS WORK How Will We Determine Caseload Reduction Credit for... requirements or State changes in eligibility rules since FY 2005 that directly affect a family's eligibility..., time limits, full family sanctions, and other new requirements that deny families assistance when an...

  6. On the Path to SunShot. Emerging Opportunities and Challenges in U.S. Solar Manufacturing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chung, Donald; Horowitz, Kelsey; Kurup, Parthiv

    This report provides insights into photovoltaic (PV) and concentrating solar power (CSP) manufacturing in the context of the U.S. Department of Energy's SunShot Initiative. Although global PV price reductions and deployment have been strong recently, PV manufacturing faces challenges. Slowing rates of manufacturing cost reductions, combined with the relatively low price of incumbent electricity generating sources in most large global PV markets, may constrain profit opportunities for firms and poses a potential challenge to the sustainable operation and growth of the global PV manufacturing base. In the United States, manufacturers also face a factors-of-production cost disadvantage compared with competing nations.more » However, the United States is one of the world's most competitive and innovative countries as well as one of the best locations for PV manufacturing. In conjunction with strong projected PV demand in the United States and across the Americas, these advantages could increase the share of PV technologies produced by U.S. manufacturers as the importance of innovation-driven PV cost reductions increases. Compared with PV, CSP systems are much more complex and require a much larger minimum effective scale, resulting in much higher total CAPEX requirements for system construction, lengthier development cycles, and ultimately higher costs of energy produced. The global lack of consistent CSP project development creates challenges for companies that manufacture specialty CSP components, and the potential lack of a near-term U.S. market could hinder domestic CSP manufacturers. However, global and U.S. CSP deployment is expected to expand beyond 2020, and U.S. CSP manufacturers could benefit from U.S. innovation advantages similar to those associated with PV. Expansion of PV and CSP manufacturing also presents U.S. job-growth opportunities.« less

  7. Evaluation of USDA approved antimicrobials on the reduction of Salmonella and Campylobacter in ground chicken frames and their effect on meat quality.

    PubMed

    Moore, A; Nannapaneni, R; Kiess, A; Sharma, C S

    2017-07-01

    The main objective of this study was to examine the efficacy of USDA approved antimicrobials in reducing Salmonella Heidelberg (S. H.) and Campylobacter jejuni (C. j.) in ground chicken frames and to determine the treatment effects on total aerobic counts and meat color. Six antimicrobials (0.1% peracetic acid [PAA], 0.6% cetylpyridinium chloride [CPC], 0.005% sodium hypochlorite, 1.5% acidified lactic acid [ALA], 0.3% propionic acid, and 0.1% lauric arginate [LAE]) applied as dip treatments were evaluated in their efficacy in reducing S. Heidelberg and C. jejuni. Fresh chicken frames were spot inoculated with nalidixic acid resistant S. H. and C. j. (ATCC 33291) to achieve a recovery level of ca. 3 log CFU/g in the ground product. Frames were dipped for 10 s in each antimicrobial solution and each treatment was replicated on 3 frames. Three separate replications were conducted for this experiment. Frames were blended, and ground samples similar to mechanically separated chicken (MSC) were obtained and stored at 4°C for 24 hours. Samples were analyzed after grinding on d zero (2 h) and d one (24 h) to determine reduction in S. H. and C. j. counts in MSC. PAA and LAE treatments had the highest reductions on Salmonella counts (P ≤ 0.05), both treatments resulting in 0.9 log CFU/g reduction as compared to control on d zero. PAA and CPC reduced Salmonella counts by 1.4 and 0.9 log CFU/g, respectively, on d one; PAA, propionic acid, ALA, and LAE resulted in one log CFU/g reductions of C. j. as compared to control on d one. There was no significant difference among the treatments in their ability to reduce C. j. on d one. The treatments had no effect on total aerobic counts. The findings from the study indicate that PAA, CPC, and LAE can reduce S. H. in ground chicken frames, whereas all the antimicrobials tested in the study, except chlorine, have the ability to reduce C. j. in ground chicken frames, a product similar to commercial MSC. © 2017 Poultry Science Association Inc.

  8. Investigation of kinematics of knuckling shot in soccer

    NASA Astrophysics Data System (ADS)

    Asai, T.; Hong, S.

    2017-02-01

    In this study, we use four high-speed video cameras to investigate the swing characteristics of the kicking leg while delivering the knuckling shot in soccer. We attempt to elucidate the impact process of the kicking foot at the instant of its impact with the ball and the technical mechanisms of the knuckling shot via comparison of its curved motion with that of the straight and curved shots. Two high-speed cameras (Fastcam, Photron Inc., Tokyo, Japan; 1000 fps, 1024 × 1024 pixels) are set up 2 m away from the site of impact with a line of sight perpendicular to the kicking-leg side. In addition, two semi-high-speed cameras (EX-F1, Casio Computer Co., Ltd., Tokyo, Japan; 300 fps; 720 × 480 pixels) are positioned, one at the rear and the other on the kicking-leg side, to capture the kicking motion. We observe that the ankle joint at impact in the knuckling shot flexes in an approximate L-shape in a manner similar to the joint flexing for the curve shot. The hip's external rotation torque in the knuckling shot is greater than those of other shots, which suggests the tendency of the kicker to push the heel forward and impact with the inside of the foot. The angle of attack in the knuckling shot is smaller than that in other shots, and we speculate that this small attack angle is a factor in soccer kicks which generate shots with smaller rotational frequencies of the ball.

  9. Acute effects of countermovement jumping and sprinting on shot put performance.

    PubMed

    Terzis, Gerasimos; Karampatsos, Giorgos; Kyriazis, Thomas; Kavouras, Stavros A; Georgiadis, Giorgos

    2012-03-01

    The purpose of this study was to investigate the acute effects of countermovement jumping and sprinting on shot put performance in experienced shot putters. Ten shot putters (best performance 13.16-20.36 m) participated in the study. After a standard warm-up including jogging, stretching, and 4-6 submaximal puts, they performed 3 shot put attempts with maximum effort, separated with 1.5-minute interval. Three minutes later, they performed 3 maximal consecutive countermovement jumps (CMJs). Immediately after jumping, they performed 3 shot put attempts with maximum effort, separated with a 1.5-minute interval. One week later, they carried out a similar protocol, at similar external conditions, but they performed a bout of 20-m sprinting instead of the CMJs, to potentiate shot put performance. Muscular strength (1 repetition maximum in squat, snatch, bench press, incline bench press) and body composition (dual x-ray absorptiometry) were measured during the same training period (±10 days from the jumping and sprinting protocols). Shot put performance was significantly increased after the CMJs (15.45 ± 2.36 vs. 15.85 ± 2.41 m, p = 0.0003). Similarly, shot put performance was significantly increased after sprinting (15.34 ± 2.41 vs. 15.90 ± 2.46 m, p = 0.0007). The increase in performance after sprinting was significantly higher compared with the increase after jumping (2.64 ± 1.59 vs. 3.74 ± 1.88%, p = 0.02). In conclusion, the results of this study indicate that a standard warm-up protocol followed by 3 maximal bouts of shot put and either 3 consecutive countermovement jumps or a bout of 20-m sprinting induce an acute increase in shot put performance in experienced shot putters.

  10. A new method for assessing squash tactics using 15 court areas for ball locations.

    PubMed

    Vučković, Goran; James, Nic; Hughes, Mike; Murray, Stafford; Milanović, Zoran; Perš, Janez; Sporiš, Goran

    2014-04-01

    Tactics in squash have typically been assessed using the frequency of different shot types played at different locations on the court either without reference to other relevant information or on the basis of the preceding shot. This paper presents a new squash specific method for categorizing court locations in which the ball was played, a novel techniques for assessing the reliability of this method and presents typical shots responses in these new areas controlled for preceding shot as well as the time between shots and the handedness of the players. Twelve games were viewed using the SAGIT/Squash software and 2907 shots viewed a second time from a video image taken from behind the court with an overall agreement of 88.90% for the court location data and 99.52% for shot type. 3192 shots from 9 matches from the 2003 World Team Championships were analyzed in SAGIT/Squash. In the court areas analyzed between 2 and 7 shot responses were predominant suggesting tactical patterns were evident. This was supported by differences evident between shot responses played from the two back corners where the backhand side was characterized by a predominance of straight drives whereas straight and crosscourt drives were played on the forehand side. These results tended to confirm that tactics i.e., consistent shot types, are played although these are only apparent when factors that determine shot selection are accounted for. This paper has controlled for some of these factors but others need to be considered e.g., if individual player profiles are to be ascertained. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Breaking the Cycle: A Special Report by Arkansas Kids Count.

    ERIC Educational Resources Information Center

    Huddleston, Rich; Duran, Angela

    In response to federal welfare reform legislation, Arkansas created the Transitional Employment Assistance (TEA) program in April 1997. The goal of this Kids Count report is to increase awareness regarding issues underlying the early implementation of TEA, focusing on caseload reductions, demographic composition of the caseload, level of support…

  12. Movement Analysis Applied to the Basketball Jump Shot--Part II.

    ERIC Educational Resources Information Center

    Martin, Thomas P.

    1981-01-01

    The jump shot is one of the most important shots in the game of basketball. The movement analysis of the jump shot designates four phases: (1) preparatory position; (2) movement phase I (crouch); (3) movement phase II (jump); and (4) follow-through. (JN)

  13. Surface roughness formation during shot peen forming

    NASA Astrophysics Data System (ADS)

    Koltsov, V. P.; Vinh, Le Tri; Starodubtseva, D. A.

    2018-03-01

    Shot peen forming (SPF) is used for forming panels and skins, and for hardening. As a rule, shot peen forming is performed after milling. Surface roughness is a complex structure, a combination of an original microrelief and shot peen forming indentations of different depths and chaotic distribution along the surface. As far as shot peen forming is a random process, surface roughness resulted from milling and shot peen forming is random too. During roughness monitoring, it is difficult to determine the basic surface area which would ensure accurate results. It can be assumed that the basic area depends on the random roughness which is characterized by the degree of shot peen forming coverage. The analysis of depth and shot peen forming indentations distribution along the surface made it possible to identify the shift of an original center profile plane and create a mathematical model for the arithmetic mean deviation of the profile. Experimental testing proved model validity and determined an inversely proportional dependency of the basic area on the degree of coverage.

  14. Shot Peening Numerical Simulation of Aircraft Aluminum Alloy Structure

    NASA Astrophysics Data System (ADS)

    Liu, Yong; Lv, Sheng-Li; Zhang, Wei

    2018-03-01

    After shot peening, the 7050 aluminum alloy has good anti-fatigue and anti-stress corrosion properties. In the shot peening process, the pellet collides with target material randomly, and generated residual stress distribution on the target material surface, which has great significance to improve material property. In this paper, a simplified numerical simulation model of shot peening was established. The influence of pellet collision velocity, pellet collision position and pellet collision time interval on the residual stress of shot peening was studied, which is simulated by the ANSYS/LS-DYNA software. The analysis results show that different velocity, different positions and different time intervals have great influence on the residual stress after shot peening. Comparing with the numerical simulation results based on Kriging model, the accuracy of the simulation results in this paper was verified. This study provides a reference for the optimization of the shot peening process, and makes an effective exploration for the precise shot peening numerical simulation.

  15. Re-presentations of space in Hollywood movies: an event-indexing analysis.

    PubMed

    Cutting, James; Iricinschi, Catalina

    2015-03-01

    Popular movies present chunk-like events (scenes and subscenes) that promote episodic, serial updating of viewers' representations of the ongoing narrative. Event-indexing theory would suggest that the beginnings of new scenes trigger these updates, which in turn require more cognitive processing. Typically, a new movie event is signaled by an establishing shot, one providing more background information and a longer look than the average shot. Our analysis of 24 films reconfirms this. More important, we show that, when returning to a previously shown location, the re-establishing shot reduces both context and duration while remaining greater than the average shot. In general, location shifts dominate character and time shifts in event segmentation of movies. In addition, over the last 70 years re-establishing shots have become more like the noninitial shots of a scene. Establishing shots have also approached noninitial shot scales, but not their durations. Such results suggest that film form is evolving, perhaps to suit more rapid encoding of narrative events. Copyright © 2014 Cognitive Science Society, Inc.

  16. Agent-Based Simulation to Support the Effectiveness, Procurement, and Employment of Non-Lethal Weapon Systems

    DTIC Science & Technology

    2017-06-01

    cases have the most significant impact on reducing the number of lethal shots fired in the simulation. Table 10 shows the reduction in the average...Figure ES-2 was developed to show the results of the focused study on maximum effective range. After analyzing the results of the 1,700 simulated...toward other agents based on whose side they are on at that time. This attribute is critical to this study as the sidedness of the local population is

  17. Supersonic Aerodynamic Design Improvements of an Arrow-Wing HSCT Configuration Using Nonlinear Point Design Methods

    NASA Technical Reports Server (NTRS)

    Unger, Eric R.; Hager, James O.; Agrawal, Shreekant

    1999-01-01

    This paper is a discussion of the supersonic nonlinear point design optimization efforts at McDonnell Douglas Aerospace under the High-Speed Research (HSR) program. The baseline for these optimization efforts has been the M2.4-7A configuration which represents an arrow-wing technology for the High-Speed Civil Transport (HSCT). Optimization work on this configuration began in early 1994 and continued into 1996. Initial work focused on optimization of the wing camber and twist on a wing/body configuration and reductions of 3.5 drag counts (Euler) were realized. The next phase of the optimization effort included fuselage camber along with the wing and a drag reduction of 5.0 counts was achieved. Including the effects of the nacelles and diverters into the optimization problem became the next focus where a reduction of 6.6 counts (Euler W/B/N/D) was eventually realized. The final two phases of the effort included a large set of constraints designed to make the final optimized configuration more realistic and they were successful albeit with a loss of performance.

  18. Survival of cold-stressed Campylobacter jejuni on ground chicken and chicken skin during frozen storage.

    PubMed

    Bhaduri, Saumya; Cottrell, Bryan

    2004-12-01

    Campylobacter jejuni is prevalent in poultry, but the effect of combined refrigerated and frozen storage on its survival, conditions relevant to poultry processing and storage, has not been evaluated. Therefore, the effects of refrigeration at 4 degrees C, freezing at -20 degrees C, and a combination of refrigeration and freezing on the survival of C. jejuni in ground chicken and on chicken skin were examined. Samples were enumerated using tryptic soy agar containing sheep's blood and modified cefoperazone charcoal deoxycholate agar. Refrigerated storage alone for 3 to 7 days produced a reduction in cell counts of 0.34 to 0.81 log10 CFU/g in ground chicken and a reduction in cell counts of 0.31 to 0.63 log10 CFU/g on chicken skin. Declines were comparable for each sample type using either plating medium. Frozen storage, alone and with prerefrigeration, produced a reduction in cell counts of 0.56 to 1.57 log10 CFU/g in ground chicken and a reduction in cell counts of 1.38 to 3.39 log10 CFU/g on chicken skin over a 2-week period. The recovery of C. jejuni following freezing was similar on both plating media. The survival following frozen storage was greater in ground chicken than on chicken skin with or without prerefrigeration. Cell counts after freezing were lower on chicken skin samples that had been prerefrigerated for 7 days than in those that had been prerefrigerated for 0, 1, or 3 days. This was not observed for ground chicken samples, possibly due to their composition. C. jejuni survived storage at 4 and -20 degrees C with either sample type. This study indicates that, individually or in combination, refrigeration and freezing are not a substitute for safe handling and proper cooking of poultry.

  19. Music video shot segmentation using independent component analysis and keyframe extraction based on image complexity

    NASA Astrophysics Data System (ADS)

    Li, Wei; Chen, Ting; Zhang, Wenjun; Shi, Yunyu; Li, Jun

    2012-04-01

    In recent years, Music video data is increasing at an astonishing speed. Shot segmentation and keyframe extraction constitute a fundamental unit in organizing, indexing, retrieving video content. In this paper a unified framework is proposed to detect the shot boundaries and extract the keyframe of a shot. Music video is first segmented to shots by illumination-invariant chromaticity histogram in independent component (IC) analysis feature space .Then we presents a new metric, image complexity, to extract keyframe in a shot which is computed by ICs. Experimental results show the framework is effective and has a good performance.

  20. Investigations of shot reproducibility for the SMP diode at 4.5 MV.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennett, Nichelle; Crain, Marlon D.; Droemer, Darryl W.

    In experiments conducted on the RITS-6 accelerator, the SMP diode exhibits sig- ni cant shot-to-shot variability. Speci cally, for identical hardware operated at the same voltage, some shots exhibit a catastrophic drop in diode impedance. A study is underway to identify sources of shot-to-shot variations which correlate with diode impedance collapse. To remove knob emission as a source, only data from a shot series conducted with a 4.5-MV peak voltage are considered. The scope of this report is limited to sources of variability which occur away from the diode, such as power ow emission and trajectory changes, variations in pulsedmore » power, dustbin and transmission line alignment, and di erent knob shapes. We nd no changes in the transmission line hardware, alignment, or hardware preparation methods which correlate with impedance collapse. However, in classifying good versus poor shots, we nd that there is not a continuous spectrum of diode impedance behavior but that the good and poor shots can be grouped into two distinct impedance pro les. This result forms the basis of a follow-on study focusing on the variability resulting from diode physics. 3« less

  1. A robust multi-shot scan strategy for high-resolution diffusion weighted MRI enabled by multiplexed sensitivity-encoding (MUSE)

    PubMed Central

    Chen, Nan-kuei; Guidon, Arnaud; Chang, Hing-Chiu; Song, Allen W.

    2013-01-01

    Diffusion weighted magnetic resonance imaging (DWI) data have been mostly acquired with single-shot echo-planar imaging (EPI) to minimize motion induced artifacts. The spatial resolution, however, is inherently limited in single-shot EPI, even when the parallel imaging (usually at an acceleration factor of 2) is incorporated. Multi-shot acquisition strategies could potentially achieve higher spatial resolution and fidelity, but they are generally susceptible to motion-induced phase errors among excitations that are exacerbated by diffusion sensitizing gradients, rendering the reconstructed images unusable. It has been shown that shot-to-shot phase variations may be corrected using navigator echoes, but at the cost of imaging throughput. To address these challenges, a novel and robust multi-shot DWI technique, termed multiplexed sensitivity-encoding (MUSE), is developed here to reliably and inherently correct nonlinear shot-to-shot phase variations without the use of navigator echoes. The performance of the MUSE technique is confirmed experimentally in healthy adult volunteers on 3 Tesla MRI systems. This newly developed technique should prove highly valuable for mapping brain structures and connectivities at high spatial resolution for neuroscience studies. PMID:23370063

  2. The killing efficiency of soft iron shot

    USGS Publications Warehouse

    Andrews, R.; Longcore, J.R.

    1969-01-01

    A cooperative research effort between the ammunition industry and the Bureau of Sport Fisheries and Wildlife is aimed at finding a suitable non-toxic substitute for lead shot. A contract study by an independent research organization evaluated ways of coating or detoxifying lead shot or replacing it with another metal. As a result of that study, the only promising candidate is soft iron. Previous tests of hard iron shot had suggested that its killing effectiveness was poor at longer ranges due to the lower density. In addition, its hardness caused excessive damage to shotgun barrels. A unique, automated shooting facility was constructed at the Patuxent Wildlife Research Center to test the killing effectiveness of soft iron shot under controlled conditions. Tethered game-farm mallards were transported across a shooting point in a manner simulating free flight. A microswitch triggered a mounted shotgun so that each shot was 'perfect.' A soft iron shot, in Number 4 size, was produced by the ammunition industry and loaded in 12-gauge shells to give optimum ballistic performance. Commercial loads of lead shot in both Number 4 and Number 6 size were used for comparison. A total of 2,010 ducks were shot at ranges of 30 to 65 yards and at broadside and head-on angles in a statistically designed procedure. The following data were recorded for each duck: time until death, broken wing or leg bones, and number of embedded shot. Those ducks not killed outright were held for 10 days. From these data, ducks were categorized as 'probably bagged,' 'probably lost cripples,' or survivors. The test revealed that the killing effectiveness of this soft iron shot was superior to its anticipated performance and close to that obtained with commercial lead loads containing an equal number of pellets. Bagging a duck, in terms of rapid death or broken wing, was primarily dependent on the probability of a shot striking that vital area, and therefore a function of range. There was no indication that iron shot would result in greater crippling loss. Despite the apparent effectiveness of this iron shot, transition to its use in waterfowl hunting is not now possible. The sample used for this test was produced by a laboratory procedure that is unsuitable for manufacture. There is no process for producing soft iron shot in the quantities needed. Industry is doing its best to resolve this problem.

  3. Effectiveness of a steam cleaning unit for disinfection in a veterinary hospital.

    PubMed

    Wood, Cheryl L; Tanner, Benjamin D; Higgins, Laura A; Dennis, Jeffrey S; Luempert, Louis G

    2014-12-01

    To evaluate whether the application of steam to a variety of surface types in a veterinary hospital would effectively reduce the number of bacteria. 5 surface types. Steam was applied as a surface treatment for disinfection to 18 test sites of 5 surface types in a veterinary hospital. A pretreatment sample was obtained by collection of a swab specimen from the left side of each defined test surface. Steam disinfection was performed on the right side of each test surface, and a posttreatment sample was then collected in the same manner from the treated (right) side of each test surface. Total bacteria for pretreatment and posttreatment samples were quantified by heterotrophic plate counts and for Staphylococcus aureus, Pseudomonas spp, and total coliforms by counts on selective media. Significant reductions were observed in heterotrophic plate counts after steam application to dog runs and dog kennel floors. A significant reduction in counts of Pseudomonas spp was observed after steam application to tub sinks. Bacterial counts were reduced, but not significantly, on most other test surfaces that had adequate pretreatment counts for quantification. Development of health-care-associated infections is of increasing concern in human and veterinary medicine. The application of steam significantly reduced bacterial numbers on a variety of surfaces within a veterinary facility. Steam disinfection may prove to be an alternative or adjunct to chemical disinfection within veterinary practices.

  4. Feasibility and reliability of the SHOT: A short scale for measuring pretreatment severity of alcohol withdrawal in the emergency department.

    PubMed

    Gray, Sara; Borgundvaag, Bjug; Sirvastava, Anita; Randall, Ian; Kahan, Meldon

    2010-10-01

    Use of a symptom-triggered scale to measure the severity of alcohol withdrawal could reduce the rate of seizures and other complications. The current standard scale, the Clinical Institute of Withdrawal Assessment (CIWA), takes a mean (±SD) of 5 minutes to complete, requiring 30 minutes of nursing time per patient when multiple measures are required. The objective was to assess the feasibility and reliability of a brief scale of alcohol withdrawal severity. The SHOT is a brief scale designed to assess alcohol withdrawal in the emergency department (ED). It includes four items: sweating, hallucinations, orientation, and tremor (SHOT). It was developed based on a literature review and a consensus process by emergency and addiction physicians. The SHOT was first piloted in one ED, and then a prospective observational study was conducted at a different ED to measure its feasibility and reliability. Subjects included patients who were in alcohol withdrawal. One nurse administered the SHOT and CIWA, and the physician repeated the SHOT independently. The SHOT was done only at baseline, before treatment was administered. In the pilot study (12 patients), the SHOT took 1 minute to complete on average, and the CIWA took 5 minutes. Sixty-one patients participated in the prospective study. For the SHOT and the CIWA done by the same nurse, the kappa was 0.88 (95% confidence interval [CI] = 0.52 to 1.0; p < 0.0001), and the Pearson's r was 0.71 (p < 0.001). The kappa for the nurse's CIWA score and the physician's SHOT score was 0.61 (95% CI = 0.25 to 0.97; p < 0.0006), and the Pearson's r was 0.48 (p = 0.002). The SHOTs performed by the nurse and physician agreed on the need for benzodiazepine treatment in 30 of 37 cases (82% agreement, kappa = 0.35, 95% CI = 0.03 to 0.67; p < 0.02). The mean (±SD) time taken by nurses and physicians to complete the SHOT was 1 (± 0.52) minute (median = 0.6 minutes). Seventeen percent of patients scored positive on the SHOT for hallucinations or disorientation. The SHOT has potential as a feasible and acceptable tool for measuring pretreatment alcohol withdrawal severity in the ED. Further research is needed to validate the SHOT, to assess the utility of serial measurements of the SHOT, and to demonstrate that its use reduces length of stay and improves clinical outcomes. © 2010 by the Society for Academic Emergency Medicine.

  5. Muscular power, neuromuscular activation, and performance in shot put athletes at preseason and at competition period.

    PubMed

    Kyriazis, Thomas A; Terzis, Gerasimos; Boudolos, Konstantinos; Georgiadis, Georgios

    2009-09-01

    The aim of this study was to investigate changes in shot put performance, muscular power, and neuromuscular activation of the lower extremities, between the preseason and the competition period, in skilled shot put athletes using the rotational technique. Shot put performance was assessed at the start of the pre-season period as well as after 12 weeks, at the competition period, in nine shot putters. Electromyographic (EMG) activity of the right vastus lateralis muscle was recorded during all shot put trials. Maximum squat strength (1RM) and mechanical parameters during the countermovement jump (CMJ) on a force platform were also determined at pre-season and at competition period. Shot put performance increased 4.7% (p < 0.05), while 1RM squat increased 6.5% (p < 0.025). EMG activity during the delivery phase was increased significantly (p < 0.025) after the training period. Shot put performance was significantly related with muscular power and takeoff velocity during the CMJ, at competition period (r = 0.66, p < 0.05 and 0.70, p < 0.05), but not with maximum vertical force. One RM squat was not related significantly with shot put performance. These results suggest that muscular power of the lower extremities is a better predictor of rotational shot put performance than absolute muscular strength in skilled athletes, at least during the competition period.

  6. Indirect monitoring shot-to-shot shock waves strength reproducibility during pump-probe experiments

    NASA Astrophysics Data System (ADS)

    Pikuz, T. A.; Faenov, A. Ya.; Ozaki, N.; Hartley, N. J.; Albertazzi, B.; Matsuoka, T.; Takahashi, K.; Habara, H.; Tange, Y.; Matsuyama, S.; Yamauchi, K.; Ochante, R.; Sueda, K.; Sakata, O.; Sekine, T.; Sato, T.; Umeda, Y.; Inubushi, Y.; Yabuuchi, T.; Togashi, T.; Katayama, T.; Yabashi, M.; Harmand, M.; Morard, G.; Koenig, M.; Zhakhovsky, V.; Inogamov, N.; Safronova, A. S.; Stafford, A.; Skobelev, I. Yu.; Pikuz, S. A.; Okuchi, T.; Seto, Y.; Tanaka, K. A.; Ishikawa, T.; Kodama, R.

    2016-07-01

    We present an indirect method of estimating the strength of a shock wave, allowing on line monitoring of its reproducibility in each laser shot. This method is based on a shot-to-shot measurement of the X-ray emission from the ablated plasma by a high resolution, spatially resolved focusing spectrometer. An optical pump laser with energy of 1.0 J and pulse duration of ˜660 ps was used to irradiate solid targets or foils with various thicknesses containing Oxygen, Aluminum, Iron, and Tantalum. The high sensitivity and resolving power of the X-ray spectrometer allowed spectra to be obtained on each laser shot and to control fluctuations of the spectral intensity emitted by different plasmas with an accuracy of ˜2%, implying an accuracy in the derived electron plasma temperature of 5%-10% in pump-probe high energy density science experiments. At nano- and sub-nanosecond duration of laser pulse with relatively low laser intensities and ratio Z/A ˜ 0.5, the electron temperature follows Te ˜ Ilas2/3. Thus, measurements of the electron plasma temperature allow indirect estimation of the laser flux on the target and control its shot-to-shot fluctuation. Knowing the laser flux intensity and its fluctuation gives us the possibility of monitoring shot-to-shot reproducibility of shock wave strength generation with high accuracy.

  7. The Use of Match Statistics that Discriminate Between Successful and Unsuccessful Soccer Teams

    PubMed Central

    Castellano, Julen; Casamichana, David; Lago, Carlos

    2012-01-01

    Three soccer World Cups were analysed with the aim of identifying the match statistics which best discriminated between winning, drawing and losing teams. The analysis was based on 177 matches played during the three most recent World Cup tournaments: Korea/Japan 2002 (59), Germany 2006 (59) and South Africa 2010 (59). Two categories of variables were studied: 1) those related to attacking play: goals scored, total shots, shots on target, shots off target, ball possession, number of off-sides committed, fouls received and corners; and 2) those related to defence: total shots received, shots on target received, shots off target received, off-sides received, fouls committed, corners against, yellow cards and red cards. Discriminant analysis of these matches revealed the following: (a) the variables related to attacking play that best differentiated between winning, drawing and losing teams were total shots, shots on target and ball possession; and (b) the most discriminating variables related to defence were total shots received and shots on target received. These results suggest that winning, drawing and losing national teams may be discriminated from one another on the basis of variables such as ball possession and the effectiveness of their attacking play. This information may be of benefit to both coaches and players, adding to their knowledge about soccer performance indicators and helping to guide the training process. PMID:23487020

  8. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kojima, Sadaoki, E-mail: kojima-s@ile.osaka-u.ac.jp, E-mail: sfujioka@ile.osaka-u.ac.jp; Ikenouchi, Takahito; Arikawa, Yasunobu

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10{sup 13} photons/shot) hard X-rays. However, high energy resolution (Δhv/hv < 0.1) is not achievable with a differential energy threshold (DET) X-ray spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolutionmore » than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO{sub 2} converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.« less

  9. Waterfowl exposure to lead and steel shot on selected hunting areas

    USGS Publications Warehouse

    White, D.H.; Stendell, R.C.

    1977-01-01

    Gizzards and wingbones from immature mallards (Anas platyrhynchos), pintails (Anas acuta), black ducks (A. rubripes), and Canada geese (Branta canadensis) were collected from 12 national and stat hunting are.as during the hunting season of 1974-75. The gizzards were examined for the occurrence of lead and steel shot and the wingbones were analyzed for lead residues. Incidence of lead shot in gizzards ranged from 1.3 percent in mallards from Monte Vista National Wildlife Refuge to 29 percent in pintails from Sauvie Island Wildlife Management Area. Lead in wingbones ranged from trace residues (<0.5 ppm) to 345 ppm. The incidence of steel shot in gizzards surpassed lead shot on some refuges that have had mandatory steel shot programs. There was a significant correlation between frequency of lead shot in gizzards and lead residues in wingbones.

  10. GENERALITY OF THE MATCHING LAW AS A DESCRIPTOR OF SHOT SELECTION IN BASKETBALL

    PubMed Central

    Alferink, Larry A; Critchfield, Thomas S; Hitt, Jennifer L; Higgins, William J

    2009-01-01

    Based on a small sample of highly successful teams, past studies suggested that shot selection (two- vs. three-point field goals) in basketball corresponds to predictions of the generalized matching law. We examined the generality of this finding by evaluating shot selection of college (Study 1) and professional (Study 3) players. The matching law accounted for the majority of variance in shot selection, with undermatching and a bias for taking three-point shots. Shot-selection matching varied systematically for players who (a) were members of successful versus unsuccessful teams, (b) competed at different levels of collegiate play, and (c) served as regulars versus substitutes (Study 2). These findings suggest that the matching law is a robust descriptor of basketball shot selection, although the mechanism that produces matching is unknown. PMID:20190921

  11. High-performance dual-energy imaging with a flat-panel detector: imaging physics from blackboard to benchtop to bedside

    NASA Astrophysics Data System (ADS)

    Siewerdsen, J. H.; Shkumat, N. A.; Dhanantwari, A. C.; Williams, D. B.; Richard, S.; Daly, M. J.; Paul, N. S.; Moseley, D. J.; Jaffray, D. A.; Yorkston, J.; Van Metter, R.

    2006-03-01

    The application of high-performance flat-panel detectors (FPDs) to dual-energy (DE) imaging offers the potential for dramatically improved detection and characterization of subtle lesions through reduction of "anatomical noise," with applications ranging from thoracic imaging to image-guided interventions. In this work, we investigate DE imaging performance from first principles of image science to preclinical implementation, including: 1.) generalized task-based formulation of NEQ and detectability as a guide to system optimization; 2.) measurements of imaging performance on a DE imaging benchtop; and 3.) a preclinical system developed in our laboratory for cardiac-gated DE chest imaging in a research cohort of 160 patients. Theoretical and benchtop studies directly guide clinical implementation, including the advantages of double-shot versus single-shot DE imaging, the value of differential added filtration between low- and high-kVp projections, and optimal selection of kVp pairs, filtration, and dose allocation. Evaluation of task-based NEQ indicates that the detectability of subtle lung nodules in double-shot DE imaging can exceed that of single-shot DE imaging by a factor of 4 or greater. Filter materials are investigated that not only harden the high-kVp beam (e.g., Cu or Ag) but also soften the low-kVp beam (e.g., Ce or Gd), leading to significantly increased contrast in DE images. A preclinical imaging system suitable for human studies has been constructed based upon insights gained from these theoretical and experimental studies. An important component of the system is a simple and robust means of cardiac-gated DE image acquisition, implemented here using a fingertip pulse oximeter. Timing schemes that provide cardiac-gated image acquisition on the same or successive heartbeats is described. Preclinical DE images to be acquired under research protocol will afford valuable testing of optimal deployment, facilitate the development of DE CAD, and support comparison of DE diagnostic imaging performance to low-dose CT and radiography.

  12. 28 CFR 79.11 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Criteria for Claims Relating to Leukemia § 79.11 Definitions. (a) Affected area means one of the following... Island, Christmas Island, the test site for the shot during Operation Wigwam, the test site for Shot Yucca during Operation Hardtack I, and the test sites for Shot Frigate Bird and Shot Swordfish during...

  13. 28 CFR 79.11 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Criteria for Claims Relating to Leukemia § 79.11 Definitions. (a) Affected area means one of the following... Island, Christmas Island, the test site for the shot during Operation Wigwam, the test site for Shot Yucca during Operation Hardtack I, and the test sites for Shot Frigate Bird and Shot Swordfish during...

  14. 28 CFR 79.11 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Criteria for Claims Relating to Leukemia § 79.11 Definitions. (a) Affected area means one of the following... Island, Christmas Island, the test site for the shot during Operation Wigwam, the test site for Shot Yucca during Operation Hardtack I, and the test sites for Shot Frigate Bird and Shot Swordfish during...

  15. 28 CFR 79.11 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Criteria for Claims Relating to Leukemia § 79.11 Definitions. (a) Affected area means one of the following... Island, Christmas Island, the test site for the shot during Operation Wigwam, the test site for Shot Yucca during Operation Hardtack I, and the test sites for Shot Frigate Bird and Shot Swordfish during...

  16. 28 CFR 79.11 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Criteria for Claims Relating to Leukemia § 79.11 Definitions. (a) Affected area means one of the following... Island, Christmas Island, the test site for the shot during Operation Wigwam, the test site for Shot Yucca during Operation Hardtack I, and the test sites for Shot Frigate Bird and Shot Swordfish during...

  17. Mindfulness meditation training effects on CD4+ T lymphocytes in HIV-1 infected adults: A small randomized controlled trial

    PubMed Central

    Creswell, J. David; Myers, Hector F.; Cole, Steven W.; Irwin, Michael R.

    2009-01-01

    Mindfulness meditation training has stress reduction benefits in various patient populations, but its effects on biological markers of HIV-1 progression are unknown. The present study tested the efficacy of an 8-week Mindfulness-based stress reduction (MBSR) meditation program compared to a 1-day control seminar on CD4+ T lymphocyte counts in stressed HIV infected adults. A single-blind randomized controlled trial was conducted with enrollment and follow-up occurring between November 2005 and December 2007. A diverse community sample of 48 HIV-1 infected adults was randomized and entered treatment in either an 8-week MBSR or a 1-day control stress reduction education seminar. The primary outcome was circulating counts of CD4+ T lymphocytes. Participants in the 1-day control seminar showed declines in CD4+ T lymphocyte counts whereas counts among participants in the 8-week MBSR program were unchanged from baseline to post-intervention (time × treatment condition interaction, p = .02). This effect was independent of antiretroviral (ARV) medication use. Additional analyses indicated that treatment adherence to the mindfulness meditation program, as measured by class attendance, mediated the effects of mindfulness meditation training on buffering CD4+ T lymphocyte declines. These findings provide an initial indication that mindfulness meditation training can buffer CD4+ T lymphocyte declines in HIV-1 infected adults. PMID:18678242

  18. Effect of Saccharomyces Boulardii Cell Wall Extracts on Colon Cancer Prevention in Male F344 Rats Treated with 1,2-Dimethylhydrazine.

    PubMed

    Fortin, Olivier; Aguilar-Uscanga, Blanca R; Vu, Khanh D; Salmieri, Stephane; Lacroix, Monique

    2018-01-01

    The effect of Saccharomyces boulardii cell wall extracts on colon cancer prevention in rats treated with 1,2-dimethylhydrazine was investigated. A crude insoluble glucan (0.5 and 1.0 mg/kg/day) and a crude mannoprotein extract (0.3 and 3.0 mg/kg/day) were administered in rats by gavage for 12 weeks along with a high fat low fiber diet whereupon rats were sacrificed and aberrant crypt foci (ACF) were counted in the colon. Moreover, NAD(P)H: quinone reductase (QR) and harmful fecal enzymes (β-glucosidase and β-glucuronidase) were quantified in the liver and in the caecum, respectively. Results showed a reduction in ACF counts, a decreased β-glucuronidase activity and an increased QR activity when rats were treated only with insoluble glucan. While these enzymatic modulations may be constituted one of the mechanisms that is responsible for the reduction of ACF counts observed, the reduction of ACF counts caused by insoluble glucan should be addressed, at least, as a biomarker of their cancer-prevention properties. To our knowledge, this is the first study demonstrated that crude cell wall extract obtained from S. boulardii could have a potential role in colon cancer prevention in vivo by revealing the potential implication of QR and β-glucuronidase modulation.

  19. A two-fold reduction in measurement time for neutron assay: Initial tests of a prototype dual-gated shift register

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, J.E.; Bourret, S.C.; Krick, M.S.

    1996-09-01

    Neutron coincidence counting (NCC) is used routinely around the world for nondestructive mass assay of uranium and plutonium in many forms, including waste. Compared with other methods, NCC is generally the most flexible, economic, and rapid. Many applications of NCC would benefit from a reduction in counting time required for a fixed random error. We have developed and tested the first prototype of a dual- gated, shift-register-based electronics unit that offers the potential of decreased measurement time for all passive and active NCC applications.

  20. A two-fold reduction in measurement time for neutron assay: Initial tests of a prototype dual-gated shift register

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, J.E.; Bourret, S.C.; Krick, M.S.

    1996-12-31

    Neutron coincidence counting (NCC) is used routinely around the world for nondestructive mass assay of uranium and plutonium in many forms, including waste. Compared with other methods, NCC is generally the most flexible, economic, and rapid. Many applications of NCC would benefit from a reduction in counting time required for a fixed random error. The authors have developed and tested the first prototype of a dual-gated, shift-register-based electronics unit that offers the potential of decreased measurement time for all passive and active NCC applications.

  1. Speckle reduction in digital holography with resampling ring masks

    NASA Astrophysics Data System (ADS)

    Zhang, Wenhui; Cao, Liangcai; Jin, Guofan

    2018-01-01

    One-shot digital holographic imaging has the advantages of high stability and low temporal cost. However, the reconstruction is affected by the speckle noise. Resampling ring-mask method in spectrum domain is proposed for speckle reduction. The useful spectrum of one hologram is divided into several sub-spectra by ring masks. In the reconstruction, angular spectrum transform is applied to guarantee the calculation accuracy which has no approximation. N reconstructed amplitude images are calculated from the corresponding sub-spectra. Thanks to speckle's random distribution, superimposing these N uncorrelated amplitude images would lead to a final reconstructed image with lower speckle noise. Normalized relative standard deviation values of the reconstructed image are used to evaluate the reduction of speckle. Effect of the method on the spatial resolution of the reconstructed image is also quantitatively evaluated. Experimental and simulation results prove the feasibility and effectiveness of the proposed method.

  2. Video Shot Boundary Detection Using QR-Decomposition and Gaussian Transition Detection

    NASA Astrophysics Data System (ADS)

    Amiri, Ali; Fathy, Mahmood

    2010-12-01

    This article explores the problem of video shot boundary detection and examines a novel shot boundary detection algorithm by using QR-decomposition and modeling of gradual transitions by Gaussian functions. Specifically, the authors attend to the challenges of detecting gradual shots and extracting appropriate spatiotemporal features that affect the ability of algorithms to efficiently detect shot boundaries. The algorithm utilizes the properties of QR-decomposition and extracts a block-wise probability function that illustrates the probability of video frames to be in shot transitions. The probability function has abrupt changes in hard cut transitions, and semi-Gaussian behavior in gradual transitions. The algorithm detects these transitions by analyzing the probability function. Finally, we will report the results of the experiments using large-scale test sets provided by the TRECVID 2006, which has assessments for hard cut and gradual shot boundary detection. These results confirm the high performance of the proposed algorithm.

  3. Influence of Running on Pistol Shot Hit Patterns.

    PubMed

    Kerkhoff, Wim; Bolck, Annabel; Mattijssen, Erwin J A T

    2016-01-01

    In shooting scene reconstructions, risk assessment of the situation can be important for the legal system. Shooting accuracy and precision, and thus risk assessment, might be correlated with the shooter's physical movement and experience. The hit patterns of inexperienced and experienced shooters, while shooting stationary (10 shots) and in running motion (10 shots) with a semi-automatic pistol, were compared visually (with confidence ellipses) and statistically. The results show a significant difference in precision (circumference of the hit patterns) between stationary shots and shots fired in motion for both inexperienced and experienced shooters. The decrease in precision for all shooters was significantly larger in the y-direction than in the x-direction. The precision of the experienced shooters is overall better than that of the inexperienced shooters. No significant change in accuracy (shift in the hit pattern center) between stationary shots and shots fired in motion can be seen for all shooters. © 2015 American Academy of Forensic Sciences.

  4. Effect of high pressure treatment on liquid whole egg

    NASA Astrophysics Data System (ADS)

    Németh, Csaba; Dalmadi, István; Mráz, Balázs; Friedrich, László; Zeke, Ildikó; Juhász, Réka; Suhajda, Ágnes; Balla, Csaba

    2012-06-01

    In our tests, we artificially infected liquid whole egg samples with Salmonella enteritidis, Listeria monocytogenes, and Staphylococcus aureus bacteria, and then treated the samples in "Food Lab900" high hydrostatic pressure (HHP) instrument for 3-17 min at 200-400 MPa. Subsequently, the change of the viable cell count of the specific bacteria has been tested. In addition to the samples infected with various bacteria, non-infected samples were also treated in each test and the change in viable cell count, colour and viscosity of the samples upon the effect of the treatment. In summary, it can be concluded that in each test of our investigations, the viable cell count of S. enteritidis critical for egg products is reduced significantly, while the reduction of the total viable cell count was around two magnitudes. Additionally, based on our results, microbial destruction, reduction of enthalpy (denaturation of egg white) caused by the treatment at HPP, and colour change are primarily affected by the pressure level, while the changes in rheological properties are also significantly affected by the duration of high pressure treatment (p<0.05).

  5. 30 CFR 75.1320 - Multiple-shot blasting.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... in a round shall be initiated in sequence from the opener hole or holes. (e) Arrangement of detonator... blasting coal off the solid— (i) Each shot in the round shall be initiated in sequence from the opener hole or holes; and (ii) After the first shot or shots, the interval between the designated delay periods...

  6. 30 CFR 75.1320 - Multiple-shot blasting.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... in a round shall be initiated in sequence from the opener hole or holes. (e) Arrangement of detonator... blasting coal off the solid— (i) Each shot in the round shall be initiated in sequence from the opener hole or holes; and (ii) After the first shot or shots, the interval between the designated delay periods...

  7. 30 CFR 75.1320 - Multiple-shot blasting.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... in a round shall be initiated in sequence from the opener hole or holes. (e) Arrangement of detonator... blasting coal off the solid— (i) Each shot in the round shall be initiated in sequence from the opener hole or holes; and (ii) After the first shot or shots, the interval between the designated delay periods...

  8. 30 CFR 75.1320 - Multiple-shot blasting.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... in a round shall be initiated in sequence from the opener hole or holes. (e) Arrangement of detonator... blasting coal off the solid— (i) Each shot in the round shall be initiated in sequence from the opener hole or holes; and (ii) After the first shot or shots, the interval between the designated delay periods...

  9. 30 CFR 75.1320 - Multiple-shot blasting.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... in a round shall be initiated in sequence from the opener hole or holes. (e) Arrangement of detonator... blasting coal off the solid— (i) Each shot in the round shall be initiated in sequence from the opener hole or holes; and (ii) After the first shot or shots, the interval between the designated delay periods...

  10. 50 CFR 32.44 - Missouri.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... approved nontoxic shot (see § 32.2(k)). 2. We allow upland game hunting on the 131-acre mainland unit of... Statewide seasons using archery methods or shotguns using shot no larger than BB. C. Big Game Hunting. We... with shot no larger than BB. 6. You may possess only approved nontoxic shot while hunting on the refuge...

  11. 50 CFR 32.44 - Missouri.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... approved nontoxic shot (see § 32.2(k)). 2. We allow upland game hunting on the 131-acre mainland unit of... Statewide seasons using archery methods or shotguns using shot no larger than BB. C. Big Game Hunting. We... with shot no larger than BB. 6. You may possess only approved nontoxic shot while hunting on the refuge...

  12. AN ECOLOGICAL RISK ASSESSMENT OF LEAD SHOT EXPOSURE IN NON-WATERFOWL AVIAN SPECIES: UPLAND GAME BIRDS AND RAPTORS

    EPA Science Inventory

    There is increasing concern that birds in terrestrial ecosystems may be exposed to spent lead shot. Evidence exists that upland birds, particularly mourning doves (Zenaida macroura), ingest spent lead shot and that raptors ingest lead shot by consuming wounded game. Mortality, ne...

  13. 50 CFR 32.44 - Missouri.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... approved nontoxic shot (see § 32.2(k)). 2. We allow upland game hunting on the 131-acre mainland unit of... Statewide seasons using archery methods or shotguns using shot no larger than BB. C. Big Game Hunting. We... with shot no larger than BB. 6. You may possess only approved nontoxic shot while hunting on the refuge...

  14. Using persuasive messages to encourage hunters to support regulation of lead shot

    USGS Publications Warehouse

    Schroeder, Susan A.; Fulton, David C.; Penning, William; Doncarlos, Kathy

    2012-01-01

    Lead shot from hunting adds the toxic metal to environments worldwide. The United States banned lead shot for hunting waterfowl in 1991 and 26 states have lead shot restrictions beyond those mandated for waterfowl hunting. The Minnesota Department of Natural Resources (MDNR) was interested in studying hunter attitudes about expanded restrictions on the use of lead shot for hunting small game to understand what communication strategies might increase public support for potential restrictions on lead shot. We mailed messages about lead shot, including 1,200 control messages and 400 of each of 9 treatment messages, and surveys to 4,800 resident small game hunters. We compared attitudes and intentions related to a possible ban among control and treatment groups. Compared to the control message, all treatment messages elicited more positive attitudes and intentions to support a ban. A basic factual message, messages with references to Ducks Unlimited, and a first-person narrative message generated the strongest support for a ban. Results also demonstrated a substantial relationship between the use of lead shot and response to persuasive messages supporting a ban.

  15. Shot-by-shot Spectrum Model for Rod-pinch, Pulsed Radiography Machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wood, William Monford

    A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thusmore » allowing for rapid optimization of the model across many shots. “Goodness of fit” is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays (“MCNPX”) model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. In conclusion, improvements to the model, specifically for application to other geometries, are discussed.« less

  16. Shot-by-shot Spectrum Model for Rod-pinch, Pulsed Radiography Machines

    DOE PAGES

    Wood, William Monford

    2018-02-07

    A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thusmore » allowing for rapid optimization of the model across many shots. “Goodness of fit” is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays (“MCNPX”) model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. In conclusion, improvements to the model, specifically for application to other geometries, are discussed.« less

  17. Effect of shot peening on surface fatigue life of carburized and hardened AISI 9310 spur gears

    NASA Technical Reports Server (NTRS)

    Townsend, D. P.; Zaretsky, E. V.

    1982-01-01

    Surface fatigue tests were conducted on two groups of AISI 9310 spur gears. Both groups were manufactured with standard ground tooth surfaces, with the second group subjected to an additional shot peening process on the gear tooth flanks. The gear pitch diameter was 8.89 cm (3.5 in.). Test conditions were a gear temperature of 350 K (170 F), a maximum Hertz stress of 1.71 billion N/sq m (248,000 psi), and a speed of 10,000 rpm. The shot peened gears exhibited pitting fatigue lives 1.6 times the life of standard gears without shot peening. Residual stress measurements and analysis indicate that the longer fatigue life is the result of the higher compressive stress produced by the shot peening. The life for the shot peened gear was calculated to be 1.5 times that for the plain gear by using the measured residual stress difference for the standard and shot peened gears. The measured residual stress for the shot peened gears was much higher than that for the standard gears.

  18. Shot-by-shot spectrum model for rod-pinch, pulsed radiography machines

    NASA Astrophysics Data System (ADS)

    Wood, Wm M.

    2018-02-01

    A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thus allowing for rapid optimization of the model across many shots. "Goodness of fit" is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays ("MCNPX") model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. Improvements to the model, specifically for application to other geometries, are discussed.

  19. Comparative toxicity of lead shot in black ducks and mallards

    USGS Publications Warehouse

    Rattner, B.A.; Fleming, W.J.

    1988-01-01

    An extreme sensitivity of pen-reared black ducks (BDs) to lead shot was observed incidental to development of an enzyme assay (Pain & Rattner, 1988). Intubation of pen-reared BDs with one no. 4 lead shot resulted in 60% mortality in 6 days. It was concluded that BDs were more sensitive to lead shot than expected, or that lead toxicity may be exacerbated by stressful conditions (elevated temperature, confinement in small pens). We reexamined lead shot toxicity in BDs and mallards (MLs). In winter 1986 (Ta=1.7-14.6? C), pen-reared and wild BDs, and game-farm and wild MLs were sham-dosed or given one no. 4 shot. After 14 days, dosed birds were redosed with two or four additional shot. Since the original observation of enhanced. shot toxicity to BDs occurred during summer, the study was also repeated in summer 1987 (Ta=I7:6-30.9?C), with pen-reared BDs and game-farm MLs. Mortality, overt intoxication, weight change, aminolevulinic acid dehydratase activity, and protoporphyrin concentration were used to compare sensitivity among groups. Sensitivity to lead shot was similar between BDs and MLs. However, the wild ducks appeared more vulnerable than their domesticated counterparts, and signs of intoxication were more pronounced in winter than in summer.

  20. Finding the gap: An empirical study of the most effective shots in elite goalball.

    PubMed

    Link, Daniel; Weber, Christoph

    2018-01-01

    This research identifies which shots types in goalball are most likely to lead to a goal and herby provides background information for improving training and competition. Therefore, we observed 117 elite level matches including 20,541 shots played in the regular situation (3 vs. 3) using notational analysis. We characterized the shots by using their target sector (A-E), technique (traditional, rotation), trajectory (flat, bounce), angle (straight, diagonal and outcome (goal, violation, out, blocked). In our data, a χ2-test showed a significantly higher goal rate for men (3.9%) compared to women (3.0%). For men, we found a significantly higher goal rate in the intersection sectors between players C (5.6%), D (4.9%), and in the outer sector A. In sector A, goal rate was higher only for straight shots (6.6%). Technique and trajectory did not affect goal rate for men, but flat shots showed a higher violation rate (3.2%) compared to bounce shouts (2.0%). In women's goalball, goal rate was higher only on sector D (4.4%). Bounce-rotation shots were the most successful (5.5%). We conclude that men should focus on shots to sectors C and D (called pocket) and straight shots to sector A, as long as there are no other tactical considerations. Women should shoot primarily towards the pocket. It might also be worth playing more bounce-rotation shots and practicing them in training.

  1. Motor and Gaze Behaviors of Youth Basketball Players Taking Contested and Uncontested Jump Shots

    PubMed Central

    van Maarseveen, Mariëtte J. J.; Oudejans, Raôul R. D.

    2018-01-01

    In this study, we examined the effects of a defender contesting jump shots on performance and gaze behaviors of basketball players taking jump shots. Thirteen skilled youth basketball players performed 48 shots from about 5 m from the basket; 24 uncontested and 24 contested. The participants wore mobile eye tracking glasses to measure their gaze behavior. As expected, an approaching defender trying to contest the shot led to significant changes in movement execution and gaze behavior including shorter shot execution time, longer jump time, longer ball flight time, later final fixation onset, and longer fixation on the defender. Overall, no effects were found for shooting accuracy. However, the effects on shot accuracy were not similar for all participants: six participants showed worse performance and six participants showed better performance in the contested compared to the uncontested condition. These changes in performance were accompanied by differences in gaze behavior. The participants with worse performance showed shorter absolute and relative final fixation duration and a tendency for an earlier final fixation offset in the contested condition compared to the uncontested condition, whereas gaze behavior of the participants with better performance for contested shots was relatively unaffected. The results confirm that a defender contesting the shot is a relevant constraint for basketball shooting suggesting that representative training designs should also include contested shots, and more generally other constraints that are representative of the actual performance setting such as time or mental pressure. PMID:29867671

  2. Indirect monitoring shot-to-shot shock waves strength reproducibility during pump–probe experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pikuz, T. A., E-mail: tatiana.pikuz@eie.eng.osaka-u.ac.jp; Photon Pioneers Center, Osaka University, Suita, Osaka 565-0871 Japan; Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow 125412

    We present an indirect method of estimating the strength of a shock wave, allowing on line monitoring of its reproducibility in each laser shot. This method is based on a shot-to-shot measurement of the X-ray emission from the ablated plasma by a high resolution, spatially resolved focusing spectrometer. An optical pump laser with energy of 1.0 J and pulse duration of ∼660 ps was used to irradiate solid targets or foils with various thicknesses containing Oxygen, Aluminum, Iron, and Tantalum. The high sensitivity and resolving power of the X-ray spectrometer allowed spectra to be obtained on each laser shot and tomore » control fluctuations of the spectral intensity emitted by different plasmas with an accuracy of ∼2%, implying an accuracy in the derived electron plasma temperature of 5%–10% in pump–probe high energy density science experiments. At nano- and sub-nanosecond duration of laser pulse with relatively low laser intensities and ratio Z/A ∼ 0.5, the electron temperature follows T{sub e} ∼ I{sub las}{sup 2/3}. Thus, measurements of the electron plasma temperature allow indirect estimation of the laser flux on the target and control its shot-to-shot fluctuation. Knowing the laser flux intensity and its fluctuation gives us the possibility of monitoring shot-to-shot reproducibility of shock wave strength generation with high accuracy.« less

  3. Finding the gap: An empirical study of the most effective shots in elite goalball

    PubMed Central

    Weber, Christoph

    2018-01-01

    This research identifies which shots types in goalball are most likely to lead to a goal and herby provides background information for improving training and competition. Therefore, we observed 117 elite level matches including 20,541 shots played in the regular situation (3 vs. 3) using notational analysis. We characterized the shots by using their target sector (A-E), technique (traditional, rotation), trajectory (flat, bounce), angle (straight, diagonal and outcome (goal, violation, out, blocked). In our data, a χ2-test showed a significantly higher goal rate for men (3.9%) compared to women (3.0%). For men, we found a significantly higher goal rate in the intersection sectors between players C (5.6%), D (4.9%), and in the outer sector A. In sector A, goal rate was higher only for straight shots (6.6%). Technique and trajectory did not affect goal rate for men, but flat shots showed a higher violation rate (3.2%) compared to bounce shouts (2.0%). In women's goalball, goal rate was higher only on sector D (4.4%). Bounce-rotation shots were the most successful (5.5%). We conclude that men should focus on shots to sectors C and D (called pocket) and straight shots to sector A, as long as there are no other tactical considerations. Women should shoot primarily towards the pocket. It might also be worth playing more bounce-rotation shots and practicing them in training. PMID:29698479

  4. Collider shot setup for Run 2 observations and suggestions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Annala, J.; Joshel, B.

    1996-01-31

    This note is intended to provoke discussion on Collider Run II shot setup. We hope this is a start of activities that will converge on a functional description of what is needed for shot setups in Collider Run II. We will draw on observations of the present shot setup to raise questions and make suggestions for the next Collider run. It is assumed that the reader has some familiarity with the Collider operational issues. Shot setup is defined to be the time between the end of a store and the time the Main Control Room declares colliding beams. This ismore » the time between Tevatron clock events SCE and SCB. This definition does not consider the time experiments use to turn on their detectors. This analysis was suggested by David Finley. The operational scenarios for Run II will require higher levels of reliability and speed for shot setup. See Appendix I and II. For example, we estimate that a loss of 3 pb{sup {minus}1}/week (with 8 hour stores) will occur if shot setups take 90 minutes instead of 30 minutes. In other words: If you do 12 shots for one week and accept an added delay of one minute in each shot, you will loose more than 60 nb{sup {minus}1} for that week alone (based on a normal shot setup of 30 minutes). These demands should lead us to be much more pedantic about all the factors that affect shot setups. Shot setup will be viewed as a distinct process that is composed of several inter- dependent `components`: procedures, hardware, controls, and sociology. These components don`t directly align with the different Accelerator Division departments, but are topical groupings of the needed accelerator functions. Defining these components, and categorizing our suggestions within them, are part of the goal of this document. Of course, some suggestions span several of these components.« less

  5. Vaccine shot-limiting: Estimating the prevalence, indicators, and impact on vaccination status - Michigan, 2012.

    PubMed

    Weinberg, Meghan; Dietz, Stephanie; Potter, Rachel; Swanson, Robert; Miller, Corinne; McFadden, Jevon

    2017-02-15

    Concerns regarding vaccine safety and pain have prompted certain parents to limit the number of shots their child receives per visit. We estimated the prevalence of shot-limited children in Michigan, described their characteristics, assessed whether shot-limited children were up-to-date on recommended vaccinations, and investigated possible intervention points for vaccination education. We analyzed vaccination registry and birth record data of children born in Michigan during 2012 who had ⩾2 vaccination visits, with ⩾1 visits after age 5months. Shot-limited was defined as receiving ⩽2 shots at all visits through age 24months. Nonlimited children received >2 shots at ⩾1 visits. Up-to-date vaccination was based on receipt of a seven-vaccine series and was determined at ages 24months and 35months. Risk ratios (RR) were calculated using risk regression. Of 101,443 children, a total of 2,967 (3%) children were shot-limited. Mothers of shot-limited children were more likely to be white (RR: 1.2; 95% confidence interval [CI]: 1.2-1.2), college graduate (RR: 1.9; 95% CI: 1.9-2.0), and married (RR: 1.5; 95% CI: 1.5-1.5). Compared with nonlimited children, shot-limited children were more likely to be born in a nonhospital setting (RR: 11.7; 95% CI: 9.4-14.6) and have a midwife attendant (RR: 1.9; 95% CI: 1.7-2.1). Shot-limited children were less likely to be up-to-date on recommended vaccinations (RR: 0.2; 95% CI: 0.2-0.3); this association was stronger for those with a midwife birth attendant (RR: 0.1; 95% CI: 0.1-0.2) rather than a medical doctor (RR: 0.3; 95% CI: 0.2-0.3). Shot-limited children are less likely to be up-to-date on vaccinations, possibly leading to increased risk for vaccine-preventable diseases. This association was stronger for those with a midwife birth attendant. This analysis should prompt targeted education, such as to midwives, concerning risks associated with shot-limiting behavior. Published by Elsevier Ltd.

  6. Vaccine shot-limiting: Estimating the prevalence, indicators, and impact on vaccination status — Michigan, 2012

    PubMed Central

    Weinberg, Meghan; Dietz, Stephanie; Potter, Rachel; Swanson, Robert; Miller, Corinne; McFadden, Jevon

    2017-01-01

    Background Concerns regarding vaccine safety and pain have prompted certain parents to limit the number of shots their child receives per visit. We estimated the prevalence of shot-limited children in Michigan, described their characteristics, assessed whether shot-limited children were up-to-date on recommended vaccinations, and investigated possible intervention points for vaccination education. Methods We analyzed vaccination registry and birth record data of children born in Michigan during 2012 who had ⩾2 vaccination visits, with ⩾1 visits after age 5 months. Shot-limited was defined as receiving ≤2 shots at all visits through age 24 months. Nonlimited children received >2 shots at ⩾1 visits. Up-to-date vaccination was based on receipt of a seven-vaccine series and was determined at ages 24 months and 35 months. Risk ratios (RR) were calculated using risk regression. Results Of 101,443 children, a total of 2,967 (3%) children were shot-limited. Mothers of shot-limited children were more likely to be white (RR: 1.2; 95% confidence interval [CI]: 1.2–1.2), college graduate (RR: 1.9; 95% CI: 1.9–2.0), and married (RR: 1.5; 95% CI: 1.5–1.5). Compared with nonlimited children, shot-limited children were more likely to be born in a nonhospital setting (RR: 11.7; 95% CI: 9.4–14.6) and have a midwife attendant (RR: 1.9; 95% CI: 1.7–2.1). Shot-limited children were less likely to be up-to-date on recommended vaccinations (RR: 0.2; 95% CI: 0.2–0.3); this association was stronger for those with a midwife birth attendant (RR: 0.1; 95% CI: 0.1–0.2) rather than a medical doctor (RR: 0.3; 95% CI: 0.2–0.3). Conclusions Shot-limited children are less likely to be up-to-date on vaccinations, possibly leading to increased risk for vaccine-preventable diseases. This association was stronger for those with a midwife birth attendant. This analysis should prompt targeted education, such as to midwives, concerning risks associated with shot-limiting behavior. PMID:28108229

  7. Quantitative assessment of growing hair counts, thickness and colour during and after treatments with a low-fluence, home-device laser: a randomized controlled trial.

    PubMed

    Thaysen-Petersen, D; Barbet-Pfeilsticker, M; Beerwerth, F; Nash, J F; Philipsen, P A; Staubach, P; Haedersdal, M

    2015-01-01

    At-home laser and intense pulsed-light hair removal continues to grow in popularity and availability. A relatively limited body of evidence is available on the course of hair growth during and after low-fluence laser usage. To assess growing hair counts, thickness and colour quantitatively during and after cessation of low-fluence laser treatment. Thirty-six women with skin phototypes I-IV and light to dark-brown axillary hairs were included. Entire axillary regions were randomized to zero or eight self-administered weekly treatments with an 810-nm home-use laser at 5·0-6·4 J cm(-2). Standardized clinical photographs were taken before each treatment and up to 3 months after the final treatment for computer-aided quantification of growing hair counts, thickness and colour. Thirty-two women completed the study protocol. During sustained treatment, there was a reduction in growing hair that reached a plateau of up to 59%, while remaining hairs became up to 38% thinner and 5% lighter (P < 0·001). The majority of subjects (77%) reported 'moderately' to 'much less hair' in treated than untreated axilla, and assessed remaining hairs as thinner and lighter (≥ 60%). After treatment cessation, hair growth gradually returned to baseline levels, and 3 months after the final treatment the count and thickness of actively growing hair exceeded pretreatment values by 29% and 7%, respectively (P ≤ 0·04). Sustained usage of low-fluence laser induced a stable reduction of growing hair counts, thickness and colour. The reduction was reversible and hairs regrew beyond baseline values after cessation of usage. Computer-aided image analysis was qualified for quantification of hair counts, thickness and colour after laser epilation. © 2014 British Association of Dermatologists.

  8. Educational outreach to reduce immunization pain in office settings.

    PubMed

    Schechter, Neil L; Bernstein, Bruce A; Zempsky, William T; Bright, Nancy S; Willard, Alice K

    2010-12-01

    The goal was to examine the impact of a teaching module on immunization pain reduction practices in pediatric offices 1 and 6 months after the intervention. Fourteen practices were selected randomly to receive a 1-hour teaching session on immunization pain reduction techniques, and 13 completed the study. Before the intervention, telephone interviews were conducted with parents concerning their children's recent immunization experiences. At 1 and 6 months after the intervention, parents of children who had recent immunizations were interviewed by using the same questionnaires. Clinicians also were surveyed at baseline and at 6 months. A total of 839 telephone interviews and 92 clinician surveys were included. Significant changes from baseline were identified at 1 and 6 months after the intervention. At 1 month, parents were more likely to report receiving information (P = .04), using strategies to reduce pain (P < .01), learning something new (P < .01), using a ShotBlocker (P < .01), using sucrose (P < .01), and having higher levels of satisfaction (P = .015). At 6 months, all rates remained significantly higher than baseline findings (all P < .01) except for satisfaction. Clinician surveys revealed significant increases in the use of longer needles, sucrose, pinwheels, focused breathing, and ShotBlockers at 6 months. A 1-hour teaching session had measurable effects on the use of pain-reducing strategies at 1 and 6 months after the intervention. This research supports the hypothesis that small-group teaching sessions at the site of care can be associated with changes in practice behaviors.

  9. Localized high-resolution DTI of the human midbrain using single-shot EPI, parallel imaging, and outer-volume suppression at 7 T

    PubMed Central

    Wargo, Christopher J.; Gore, John C.

    2013-01-01

    Localized high-resolution diffusion tensor images (DTI) from the midbrain were obtained using reduced field-of-view (rFOV) methods combined with SENSE parallel imaging and single-shot echo planar (EPI) acquisitions at 7 T. This combination aimed to diminish sensitivities of DTI to motion, susceptibility variations, and EPI artifacts at ultra-high field. Outer-volume suppression (OVS) was applied in DTI acquisitions at 2- and 1-mm2 resolutions, b=1000 s/mm2, and six diffusion directions, resulting in scans of 7- and 14-min durations. Mean apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were measured in various fiber tract locations at the two resolutions and compared. Geometric distortion and signal-to-noise ratio (SNR) were additionally measured and compared for reduced-FOV and full-FOV DTI scans. Up to an eight-fold data reduction was achieved using DTI-OVS with SENSE at 1 mm2, and geometric distortion was halved. The localization of fiber tracts was improved, enabling targeted FA and ADC measurements. Significant differences in diffusion properties were observed between resolutions for a number of regions suggesting that FA values are impacted by partial volume effects even at a 2-mm2 resolution. The combined SENSE DTI-OVS approach allows large reductions in DTI data acquisition and provides improved quality for high-resolution diffusion studies of the human brain. PMID:23541390

  10. Effect of Probiotic Curd on Salivary pH and Streptococcus mutans: A Double Blind Parallel Randomized Controlled Trial.

    PubMed

    Srivastava, Shivangi; Saha, Sabyasachi; Kumari, Minti; Mohd, Shafaat

    2016-02-01

    Dairy products like curd seem to be the most natural way to ingest probiotics which can reduce Streptococcus mutans level and also increase salivary pH thereby reducing the dental caries risk. To estimate the role of probiotic curd on salivary pH and Streptococcus mutans count, over a period of 7 days. This double blind parallel randomized clinical trial was conducted at the institution with 60 caries free volunteers belonging to the age group of 20-25 years who were randomly allocated into two groups. Test Group consisted of 30 subjects who consumed 100ml of probiotic curd daily for seven days while an equal numbered Control Group were given 100ml of regular curd for seven days. Saliva samples were assessed at baseline, after ½ hour 1 hour and 7 days of intervention period using pH meter and Mitis Salivarius Bacitracin agar to estimate salivary pH and S. mutans count. Data was statistically analysed using Paired and Unpaired t-test. The study revealed a reduction in salivary pH after ½ hour and 1 hour in both the groups. However after 7 days, normal curd showed a statistically significant (p< 0.05) reduction in salivary pH while probiotic curd showed a statistically significant (p< 0.05) increase in salivary pH. Similarly with regard to S. mutans colony counts probiotic curd showed statistically significant reduction (p< 0.05) as compared to normal curd. Short-term consumption of probiotic curds showed marked salivary pH elevation and reduction of salivary S. mutans counts and thus can be exploited for the prevention of enamel demineralization as a long-term remedy keeping in mind its cost effectiveness.

  11. 77 FR 36980 - Migratory Bird Hunting; Application for Approval of Copper-Clad Iron Shot as Nontoxic for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-20

    ... of Copper-Clad Iron Shot as Nontoxic for Waterfowl Hunting AGENCY: Fish and Wildlife Service, Interior. ACTION: Notice of application for nontoxic shot approval. SUMMARY: We, the U.S. Fish and Wildlife Service, announce that Environ- Metal, Inc., of Sweet Home, Oregon, has applied for our approval of shot...

  12. [Contact shot from infantry weapons with a flash-suppressor].

    PubMed

    Perdekamp, Markus Grosse; Braunwarth, Roland; Schmidt, Ulrike; Schmidt, Wolfgang; Pollak, Stefan

    2003-01-01

    The number of reports on contact shots from firearms with a flash suppressor attached to the muzzle is small. On the basis of a case report (suicidal shot to the forehead with a Kalschnikow AKMS 47 assault rifle) the morphological peculiarities (characteristics soot pattern, relatively small powder cavity and only minor skin tears in the presence of a bony support) are presented and the conclusions to be drawn from the findings regarding the flash-suppressor, the shot distance, the angle of the shot and the way of holding the weapon are discussed.

  13. Characterization of Bird Impacts on a Rigid Plate: Part 1

    DTIC Science & Technology

    1975-01-01

    a breech block at the breech end and a sabot stopper at the muzzle. Four longitudinal slits 46 cm long, 0. 318 cm wide, terminating 36 cm from the...series, the two PCB 118 transducers performed ratisfactorily for 71 shots and displayod no indications of imminent failure, 20 I1I Iz AFFDL-TR-75-5...75-5 Shot No. 4951; velocity 215 rn/s Shot No. 4965; velocity Z01 rn/s A-3 AFFDL-TR-75-5 Shot No. 2986; velocity 71 rn/s Shot No. 4987; velocity 105 i

  14. Mug shot exposure prior to lineup identification: interference, transference, and commitment effects.

    PubMed

    Dysart, J E; Lindsay, R C; Hammond, R; Dupuis, P

    2001-12-01

    The effects of viewing mug shots on subsequent identification performance are as yet unclear. Two experiments used a live staged-crime paradigm to determine if interpolated eyewitness exposure to mug shots caused interference, unconscious transference, or commitment effects influencing subsequent lineup accuracy. Experiment 1 (N = 104) tested interference effects. Similar correct decision rates were obtained for the mug shot and no mug shot groups from both perpetrator-present and absent lineups. Experiment 2 (N = 132) tested for commitment and transference effects. Results showed that the commitment group made significantly more incorrect identifications than either the control or the transference group, which had similar false-identification rates. Commitment effects present a serious threat to identification accuracy from lineups following mug shot searches.

  15. Billion shot flashlamp for spaceborne lasers

    NASA Technical Reports Server (NTRS)

    Richter, Linda; Schuda, Felix; Degnan, John

    1990-01-01

    A billion-shot flashlamp developed under a NASA contract for spaceborne laser missions is presented. Lifetime-limiting mechanisms are identified and addressed. Two energy loadings of 15 and 44 Joules were selected for the initial accelerated life testing. A fluorescence-efficiency test station was used for measuring the useful-light output degradation of the lamps. The design characteristics meeting NASA specifications are outlined. Attention is focused on the physical properties of tungsten-matrix cathodes, the chemistry of dispenser cathodes, and anode degradation. It is reported that out of the total 83 lamps tested in the program, 4 lamps reached a billion shots and one lamp is beyond 1.7 billion shots, while at 44 Joules, 4 lamps went beyond 100 million shots and one lamp reached 500 million shots.

  16. An upper limit on ultraviolet shot noise from Cygnus X-1

    NASA Technical Reports Server (NTRS)

    Duthie, J. G.; Mcmillan, R. S.

    1979-01-01

    Rapid photometry of Cygnus X-1 through an ultraviolet filter centered on 0.35 micron has been obtained at 100-ms sampling intervals. The autocorrelation function of these data has been examined for shot noise analogous to the behavior of the X-ray light curve. The ultraviolet data are entirely consistent with white noise. Considering randomly occurring ultraviolet shots with the same duration (0.5 s) and average rate (1 per sec) as the X-ray shots, a 3-sigma upper limit on the ratio of optical to X-ray energies per shot is estimated to be 0.13, before the ultraviolet light is attenuated by interstellar dust. This limit is then generalized for shots of arbitrary duration and rate.

  17. Mask data processing in the era of multibeam writers

    NASA Astrophysics Data System (ADS)

    Abboud, Frank E.; Asturias, Michael; Chandramouli, Maesh; Tezuka, Yoshihiro

    2014-10-01

    Mask writers' architectures have evolved through the years in response to ever tightening requirements for better resolution, tighter feature placement, improved CD control, and tolerable write time. The unprecedented extension of optical lithography and the myriad of Resolution Enhancement Techniques have tasked current mask writers with ever increasing shot count and higher dose, and therefore, increasing write time. Once again, we see the need for a transition to a new type of mask writer based on massively parallel architecture. These platforms offer a step function improvement in both dose and the ability to process massive amounts of data. The higher dose and almost unlimited appetite for edge corrections open new windows of opportunity to further push the envelope. These architectures are also naturally capable of producing curvilinear shapes, making the need to approximate a curve with multiple Manhattan shapes unnecessary.

  18. Design, Fabrication, Calibration, Testing and Satellite Integration of a Space-Radiation Dosimeter.

    DTIC Science & Technology

    1981-12-01

    on aI to tuec 11i’u te I ~ .t .r e t~tnJt IIIt Heil(-V- e Nxonknlt al Ii) ao (k Iowa rd’ t ht in i )I, ii, r’ iuie scent v-ia s p uift. i ne alipi. r...exponent are interpreted conventionally: M = m 1 + 2m2 + 4m 3 + 8m 4 + 1 6m 5 and E = e1 + 2e2 +4e 3 The minimum number of input counts required to cause a...R Q,, TE L26 INIT 0 ne One - f-..t ht shot ShoIEZTT CHI ST R,.et ST CAL ST s a D Q CAL ID mux c Hli DR I .10V R Cw DR 2 DR 3 LO. C.-H-FE DR 4 One

  19. Graz kHz SLR LIDAR: first results

    NASA Astrophysics Data System (ADS)

    Kirchner, Georg; Koidl, Franz; Kucharski, Daniel; Pachler, Walther; Seiss, Matthias; Leitgeb, Erich

    2009-05-01

    The Satellite Laser Ranging (SLR) Station Graz is measuring routinely distances to satellites with a 2 kHz laser, achieving an accuracy of 2-3 mm. Using this available equipment, we developed - and added as a byproduct - a kHz SLR LIDAR for the Graz station: Photons of each transmitted laser pulse are backscattered from clouds, atmospheric layers, aircraft vapor trails etc. An additional 10 cm diameter telescope - installed on our main telescope mount - and a Single- Photon Counting Module (SPCM) detect these photons. Using an ISA-Bus based FPGA card - developed in Graz for the kHz SLR operation - these detection times are stored with 100 ns resolution (15 m slots in distance). Event times of any number of laser shots can be accumulated in up to 4096 counters (according to > 60 km distance). The LIDAR distances are stored together with epoch time and telescope pointing information; any reflection point is therefore determined with 3D coordinates, with 15 m resolution in distance, and with the angular precision of the laser telescope pointing. First test results to clouds in full daylight conditions - accumulating up to several 100 laser shots per measurement - yielded high LIDAR data rates (> 100 points per second) and excellent detection of clouds (up to 10 km distance at the moment). Our ultimate goal is to operate the LIDAR automatically and in parallel with the standard SLR measurements, during day and night, collecting LIDAR data as a byproduct, and without any additional expenses.

  20. Spectraplakins promote microtubule-mediated axonal growth by functioning as structural microtubule-associated proteins and EB1-dependent +TIPs (tip interacting proteins).

    PubMed

    Alves-Silva, Juliana; Sánchez-Soriano, Natalia; Beaven, Robin; Klein, Melanie; Parkin, Jill; Millard, Thomas H; Bellen, Hugo J; Venken, Koen J T; Ballestrem, Christoph; Kammerer, Richard A; Prokop, Andreas

    2012-07-04

    The correct outgrowth of axons is essential for the development and regeneration of nervous systems. Axon growth is primarily driven by microtubules. Key regulators of microtubules in this context are the spectraplakins, a family of evolutionarily conserved actin-microtubule linkers. Loss of function of the mouse spectraplakin ACF7 or of its close Drosophila homolog Short stop/Shot similarly cause severe axon shortening and microtubule disorganization. How spectraplakins perform these functions is not known. Here we show that axonal growth-promoting roles of Shot require interaction with EB1 (End binding protein) at polymerizing plus ends of microtubules. We show that binding of Shot to EB1 requires SxIP motifs in Shot's C-terminal tail (Ctail), mutations of these motifs abolish Shot functions in axonal growth, loss of EB1 function phenocopies Shot loss, and genetic interaction studies reveal strong functional links between Shot and EB1 in axonal growth and microtubule organization. In addition, we report that Shot localizes along microtubule shafts and stabilizes them against pharmacologically induced depolymerization. This function is EB1-independent but requires net positive charges within Ctail which essentially contribute to the microtubule shaft association of Shot. Therefore, spectraplakins are true members of two important classes of neuronal microtubule regulating proteins: +TIPs (tip interacting proteins; plus end regulators) and structural MAPs (microtubule-associated proteins). From our data we deduce a model that relates the different features of the spectraplakin C terminus to the two functions of Shot during axonal growth.

  1. The kinematics of table tennis racquet: differences between topspin strokes.

    PubMed

    Bańkosz, Ziemowit; Winiarski, Sławomir

    2017-03-01

    Studies of shot kinematics in table tennis have not been sufficiently described in the literature. The assessment of the racquet trajectory, its speed and time characteristics makes it possible to emphasize on certain technical elements in the training process in order, for example, to increase strength, speed of rotation or speed of the shot while maintaining its accuracy. The aim of this work was to measure selected kinematic parameters of table tennis racquet during forehand and backhand topspin shots, while considering the differences between these strokes in table tennis. The measurements took place in a certified biomechanical laboratory using a motion analysis system. The study involved 12 female table tennis players in high-level sports training and performance. Each subject had to complete series of six tasks, presenting different varieties of topspin shots. The longest racquet trajectory was related to forehand shots, shots played against a ball with backspin and winner shots. The maximum racquet velocity was precisely in the moment of impact with the ball. The individual of velocity and distance were larger in the direction of the acting force, depending on the individual shot. Changing the type of topspin shot requires changes of time, velocity and primarily distance parameters as well as the direction of the playing racquet. The maximum speed of the racquet occurring at the moment of the impact is probably the most important principle in playing technique. The results can be directly used in improving training of table tennis techniques, especially in the application and use of topspin shots.

  2. Effect of resonant magnetic perturbations on three dimensional equilibria in the Madison Symmetric Torus reversed-field pinch

    NASA Astrophysics Data System (ADS)

    Munaretto, S.; Chapman, B. E.; Nornberg, M. D.; Boguski, J.; DuBois, A. M.; Almagri, A. F.; Sarff, J. S.

    2016-05-01

    The orientation of 3D equilibria in the Madison Symmetric Torus (MST) [R. N. Dexter et al., Fusion Technol. 19, 131 (1991)] reversed-field pinch can now be controlled with a resonant magnetic perturbation (RMP). Absent the RMP, the orientation of the stationary 3D equilibrium varies from shot to shot in a semi-random manner, making its diagnosis difficult. Produced with a poloidal array of saddle coils at the vertical insulated cut in MST's thick conducting shell, an m = 1 RMP with an amplitude br/B ˜ 10% forces the 3D structure into any desired orientation relative to MST's diagnostics. This control has led to improved diagnosis, revealing enhancements in both the central electron temperature and density. With sufficient amplitude, the RMP also inhibits the generation of high-energy (>20 keV) electrons, which otherwise emerge due to a reduction in magnetic stochasticity in the core. Field line tracing reveals that the RMP reintroduces stochasticity to the core. A m = 3 RMP of similar amplitude has little effect on the magnetic topology or the high-energy electrons.

  3. Simulation of the impact of refractive surgery ablative laser pulses with a flying-spot laser beam on intrasurgery corneal temperature.

    PubMed

    Shraiki, Mario; Arba-Mosquera, Samuel

    2011-06-01

    To evaluate ablation algorithms and temperature changes in laser refractive surgery. The model (virtual laser system [VLS]) simulates different physical effects of an entire surgical process, simulating the shot-by-shot ablation process based on a modeled beam profile. The model is comprehensive and directly considers applied correction; corneal geometry, including astigmatism; laser beam characteristics; and ablative spot properties. Pulse lists collected from actual treatments were used to simulate the temperature increase during the ablation process. Ablation efficiency reduction in the periphery resulted in a lower peripheral temperature increase. Steep corneas had lesser temperature increases than flat ones. The maximum rise in temperature depends on the spatial density of the ablation pulses. For the same number of ablative pulses, myopic corrections showed the highest temperature increase, followed by myopic astigmatism, mixed astigmatism, phototherapeutic keratectomy (PTK), hyperopic astigmatism, and hyperopic treatments. The proposed model can be used, at relatively low cost, for calibration, verification, and validation of the laser systems used for ablation processes and would directly improve the quality of the results.

  4. Comparative Effectiveness of Two Walking Interventions on Participation, Step Counts, and Health.

    PubMed

    Smith-McLallen, Aaron; Heller, Debbie; Vernisi, Kristin; Gulick, Diana; Cruz, Samantha; Snyder, Richard L

    2017-03-01

    To (1) compare the effects of two worksite-based walking interventions on employee participation rates; (2) compare average daily step counts between conditions, and; (3) examine the effects of increases in average daily step counts on biometric and psychologic outcomes. We conducted a cluster-randomized trial in which six employer groups were randomly selected and randomly assigned to condition. Four manufacturing worksites and two office-based worksite served as the setting. A total of 474 employees from six employer groups were included. A standard walking program was compared to an enhanced program that included incentives, feedback, competitive challenges, and monthly wellness workshops. Walking was measured by self-reported daily step counts. Survey measures and biometric screenings were administered at baseline and 3, 6, and 9 months after baseline. Analysis used linear mixed models with repeated measures. During 9 months, participants in the enhanced condition averaged 726 more steps per day compared with those in the standard condition (p < .001). A 1000-step increase in average daily steps was associated with significant weight loss for both men (-3.8 lbs.) and women (-2.1 lbs.), and reductions in body mass index (-0.41 men, -0.31 women). Higher step counts were also associated with improvements in mood, having more energy, and higher ratings of overall health. An enhanced walking program significantly increases participation rates and daily step counts, which were associated with weight loss and reductions in body mass index.

  5. Single-shot spiral imaging at 7 T.

    PubMed

    Engel, Maria; Kasper, Lars; Barmet, Christoph; Schmid, Thomas; Vionnet, Laetitia; Wilm, Bertram; Pruessmann, Klaas P

    2018-03-25

    The purpose of this work is to explore the feasibility and performance of single-shot spiral MRI at 7 T, using an expanded signal model for reconstruction. Gradient-echo brain imaging is performed on a 7 T system using high-resolution single-shot spiral readouts and half-shot spirals that perform dual-image acquisition after a single excitation. Image reconstruction is based on an expanded signal model including the encoding effects of coil sensitivity, static off-resonance, and magnetic field dynamics. The latter are recorded concurrently with image acquisition, using NMR field probes. The resulting image resolution is assessed by point spread function analysis. Single-shot spiral imaging is achieved at a nominal resolution of 0.8 mm, using spiral-out readouts of 53-ms duration. High depiction fidelity is achieved without conspicuous blurring or distortion. Effective resolutions are assessed as 0.8, 0.94, and 0.98 mm in CSF, gray matter and white matter, respectively. High image quality is also achieved with half-shot acquisition yielding image pairs at 1.5-mm resolution. Use of an expanded signal model enables single-shot spiral imaging at 7 T with unprecedented image quality. Single-shot and half-shot spiral readouts deploy the sensitivity benefit of high field for rapid high-resolution imaging, particularly for functional MRI and arterial spin labeling. © 2018 International Society for Magnetic Resonance in Medicine.

  6. Toxicity of Lead and Proposed Substitute Shot to Mallards

    USGS Publications Warehouse

    Longcore, J.R.; Andrews, R.; Locke, L.N.; Bagley, George E.; Young, L.T.

    1974-01-01

    Poisoning of North American waterfowl resulting from the ingestion of lead shot by ducks, geese, and swans causes an estimated annual mortality of 2 to 3% of the population (Bellrose 1959). To alleviate this problem the search for a suitable substitute for lead has been underway since the early 1950's. Proposed substitutes for lead shot were evaluated in a series of acute toxicity tests with pen-reared mallards (Anas platyrhynchos). Most candidate materials were as toxic to ducks as commercial lead shot. Coating or alloying lead with other metals only delayed mortality among dosed ducks. The reputedly 'disintegrable' lead shot with the water-soluble binder and the lead containing biochemical additives were also as toxic to mallards as the commercial lead shot. Mortality was not significantly different among lead-dosed adult or first-year hen and drake pen-reared mallards; lead-dosed adult, wild mallards of both sexes; and lead-dosed adult, male black ducks (Anas rubripes). The ingestion of one lead shot, size 4, by each of 80 pen-reared mallards caused an average 19% mortality. The presence and type of grit in the gizzard had a measurable effect on erosion of ingested shot and on shot retention among dosed mallards. Significantly fewer lead-dosed ducks died when fed crushed oystershell grit than when fed either quartz grit or no grit.

  7. A focal-spot diagnostic for on-shot characterization of high-energy petawatt lasers.

    PubMed

    Bromage, J; Bahk, S-W; Irwin, D; Kwiatkowski, J; Pruyne, A; Millecchia, M; Moore, M; Zuegel, J D

    2008-10-13

    An on-shot focal-spot diagnostic for characterizing high-energy, petawatt-class laser systems is presented. Accurate measurements at full energy are demonstrated using high-resolution wavefront sensing in combination with techniques to calibrate on-shot measurements with low-power sample beams. Results are shown for full-energy activation shots of the OMEGA EP Laser System.

  8. Investigation on surface layer characteristics of shot peened graphene reinforced Al composite by X-ray diffraction method

    NASA Astrophysics Data System (ADS)

    Zhan, Ke; Wu, Yihao; Li, Jiongli; Zhao, Bin; Yan, Ya; Xie, Lechun; Wang, Lianbo; Ji, V.

    2018-03-01

    Graphene reinforced Al composite with high mechanical property was successfully reported. However, there are quite limited studies about shot peening effect on this new type material. Here, 1.0 wt% graphene reinforced Al composite was produced by powder metallurgy and treated by shot peening. The surface layer characteristics of shot peened composite was investigated by X-ray diffraction line profile analysis. The microstructure including domain size, micro-strain, dislocation density and crystalline texture were analyzed. The results showed that after surface shot-peening, the domain size were refined, the dislocation density of the composite was increased sharply to 9.0 × 1011/cm2 at the top surface. The original strong texture was diminished after shot peening. Based on the calculated results, the microstructure variation of composite was more severe than that of Al without graphene reinforcement after shot peening. Besides, the micro-hardness of composite at the top surface increased up to 75HV one time higher than that of matrix. It is concluded that shot peening can be considered as an essential process of improving the surface properties of graphene reinforced Al composite.

  9. Seismic waveform tomography with shot-encoding using a restarted L-BFGS algorithm.

    PubMed

    Rao, Ying; Wang, Yanghua

    2017-08-17

    In seismic waveform tomography, or full-waveform inversion (FWI), one effective strategy used to reduce the computational cost is shot-encoding, which encodes all shots randomly and sums them into one super shot to significantly reduce the number of wavefield simulations in the inversion. However, this process will induce instability in the iterative inversion regardless of whether it uses a robust limited-memory BFGS (L-BFGS) algorithm. The restarted L-BFGS algorithm proposed here is both stable and efficient. This breakthrough ensures, for the first time, the applicability of advanced FWI methods to three-dimensional seismic field data. In a standard L-BFGS algorithm, if the shot-encoding remains unchanged, it will generate a crosstalk effect between different shots. This crosstalk effect can only be suppressed by employing sufficient randomness in the shot-encoding. Therefore, the implementation of the L-BFGS algorithm is restarted at every segment. Each segment consists of a number of iterations; the first few iterations use an invariant encoding, while the remainder use random re-coding. This restarted L-BFGS algorithm balances the computational efficiency of shot-encoding, the convergence stability of the L-BFGS algorithm, and the inversion quality characteristic of random encoding in FWI.

  10. Shots by STFM: value of immunization software to family medicine residency directors: a CERA study.

    PubMed

    Nowalk, Mary Patricia; Clinch, C Randall; Tarn, Derjung M; Chang, Tammy; Ncube, Collette N; Troy, Judith A; Zimmerman, Richard K

    2012-01-01

    The Group on Immunization Education (GIE) of the Society of Teachers of Family Medicine (STFM) has developed Shots by STFM immunization software, which is available free of charge for a variety of platforms. It is routinely updated with the Center for Disease Control and Prevention's (CDC's) most recent immunization schedules. Successful development and marketing of teaching resources requires periodic evaluation of their use and value to their target audience. This study was undertaken to evaluate the 2011 version of Shots by STFM. Family medicine residency directors were surveyed about their use of Shots by STFM for teaching residents and their ratings of its features. The response rate for the survey was 38% (172/452). While awareness of Shots by STFM among responding residency directors was low (57%), ratings by those using the resource were excellent. Thirty percent of respondents recommend or require their residents to use Shots by STFM. Better marketing of Shots by STFM to family medicine residency directors seems to be indicated.

  11. Jello Shot Consumption among Underage Youths in the United States

    PubMed Central

    SIEGEL, MICHAEL; GALLOWAY, ASHLEY; ROSS, CRAIG S.; BINAKONSKY, JANE; JERNIGAN, DAVID H.

    2015-01-01

    We sought, for the first time, to identify the extent of jello shot consumption among underage youth. We conducted a study among a national sample of 1,031 youth, aged 13 to 20, using a pre-recruited internet panel maintained by GfK Knowledge Networks to assess past 30-day consumption of jello shots. Nearly one-fifth of underage youth have consumed jello shots in the past 30 days and jello shots make up an average of nearly 20% of their overall alcohol intake. Jello shot users in our sample were approximately 1.5 times more likely to binge drink, consumed approximately 1.6 times as many drinks per month, and were 1.7 times more likely to have been in a physical fight related to their alcohol use as drinkers in general. Ascertainment of jello shot use should become a standard part of youth alcohol surveillance and states should consider banning the sale of these products. PMID:27087771

  12. Shot noise limit of chemically amplified resists with photodecomposable quenchers used for extreme ultraviolet lithography

    NASA Astrophysics Data System (ADS)

    Kozawa, Takahiro; Santillan, Julius Joseph; Itani, Toshiro

    2017-06-01

    In lithography using high-energy photons such as an extreme ultraviolet (EUV) radiation, the shot noise of photons is a critical issue. The shot noise is a cause of line edge/width roughness (LER/LWR) and stochastic defect generation and limits the resist performance. In this study, the effects of photodecomposable quenchers were investigated from the viewpoint of the shot noise limit. The latent images of line-and-space patterns with 11 nm half-pitch were calculated using a Monte Carlo method. In the simulation, the effect of secondary electron blur was eliminated to clarify the shot noise limits regarding stochastic phenomena such as LER. The shot noise limit for chemically amplified resists with acid generators and photodecomposable quenchers was approximately the same as that for chemically amplified resists with acid generators and conventional quenchers when the total sensitizer concentration was the same. The effect of photodecomposable quenchers on the shot noise limit was essentially the same as that of acid generators.

  13. Age-associated reduction of the count and functional activity of stromal precursor cells can be caused by both true reduction (exhaustion) of cell pool and regulatory effects of the organism.

    PubMed

    Gorskaya, Yu F; Danilova, T A; Nesterenko, V G

    2011-06-01

    The study was carried out on CBA mice using the method of heterotopic transplantation. A fragment of the femoral bone marrow (1/2) or spleen (1/5 of the organ) was transplanted under the renal capsule of a recipient. The following donor-recipient cross-transplantation variants were studied: young-young (Y-Y), young-old (Y-O), old-old (O-O), and old-young (O-Y). Cell suspensions were prepared from 2-month transplants inoculated in monolayer cultures and the cloning efficiency (ECF-F) of stromal precursor cells (CFC-F) was evaluated. The bone marrow transplant ECF-F and the count of CFC-F in the O-O group were 8-fold lower than in the Y-Y group. In the O-Y group, ECF-F was 3-fold higher than in the O-O group, but by 2.5 times lower than in the Y-Y group. ECF-F in Y-O group was 2-fold lower than in Y-Y group. The ECF-F and CFC-F count in spleen transplants in the O-O group were 4- and 6-fold lower, respectively, than in Y-Y group. However, in O-Y group ECF-F was 7-fold higher than in O-O group and higher than even in Y-Y group. The weight of induced ectopic bone tissue after transplantation of the osteoinductor (fragments of the allogenic urinary bladder mucosa) was 2-fold lower in the O-O vs. Y-Y group. However, comparison of the ectopic bone tissue weights in different experimental groups showed that osteoinductor activity of the bladder epithelium did not decrease, but increased 3-fold with age (O-Y:Y-Y). A 5-fold reduction of this proportion in groups where the osteoinductor was transplanted from old donors to old and young recipients (O-Y:O-O) could be attributed to age-specific reduction of the count of inducible osteogenic precursor cells (IOPC). The data in general suggest that age-specific reduction of the stromal precursor count and functional activity could be caused by the true reduction (exhaustion) of cell pool (bone marrow CFC-F; presumably, IOPC) and by the regulatory effects of the organism (bone marrow and splenic CFC-F, IOPC). These data seem to be significant for understanding of the role of osteogenic stromal precursor cells in the development of age-associated bone tissue defects, for example, senile osteoporosis.

  14. Seasonal ingestion of toxic and nontoxic shot by Canada geese

    USGS Publications Warehouse

    DeStefano, S.; Brand, C.J.; Samuel, M.D.

    1995-01-01

    We used rates of ingested shot and elevated blood-lead levels (≥0.18 ppm) to estimate the proportion of Canada geese (Branta canadensis) exposed to lead on 3 study areas in Manitoba, Minnesota, and Missouri. Lead exposure was prevalent on all areas and was common after the hunting season closed, when up to 15% of geese could have been exposed to lead shot. However, the proportion of steel shot ingested by geese has increased during the past 2 decades. We suggest that lead exposure is still a source of indirect hunting mortality in Canada geese but project that the prevalence of lead exposure in the Eastern Prairie Population and other waterfowl populations will decrease as nontoxic shot regulations persist and hunters use steel or other nontoxic shot.

  15. Body hair counts during hair length reduction procedures: a comparative study between Computer Assisted Image Analysis after Manual Processing (CAIAMP) and Trichoscan(™).

    PubMed

    Van Neste, D J J

    2015-08-01

    To compare two measurement methods for body hair. Calibration of computer assisted image analysis after manual processing (CAIAMP) showed variation <4% for thickness and <2.3% for densities. Images from 6 body sites with 'good natural contrast between hair and skin' were taken before hair dye, after hair dye or after hair length reduction without hair extraction or destruction. Data in the same targets were compared with Trichoscan(™) quoted for 'unambiguous evaluation of the hair growth after shaving'. CAIAMP detected a total of 337 hair and showed no statistically significant differences with the three procedures confirming 'good natural contrast between hair and skin' and that reduction methods did not affect hair counts. While CAIAMP found a mean number of 19 thick hair (≥30 μm) before dye, 18 after dye and 20 after hair reduction, Trichoscan(™) found in the same sites respectively 44, 73 and 61. Trichoscan(™) generated counts differed statistically significantly from CAIAMP-data. Automated analyses were considered un-specifically influenced by hair medulla and natural or artificial skin background. Quality control including all steps of human intervention and measurement technology are mandatory for body hair measurements during experimental or clinical trials on body hair grooming, shaving or removal. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Environmental Impact of Controlled-Source Explosions in Ethiopia (Project EAGLE): Surface Shaking, Ground Velocities, and Effects on Buildings

    NASA Astrophysics Data System (ADS)

    Les, A.; Klemperer, S. L.; Keranen, K.; Khan, A.; Maguire, P.

    2003-12-01

    In January 2003, as part of the Ethiopia-Afar Geoscientific Lithospheric Experiment (EAGLE) we conducted a refraction and wide-angle reflection survey of the Main Ethiopian Rift. 757 RefTek "Texan" seismographs with vertical geophones were deployed in 400 km-long axial and cross-rift lines, with another 231 in a central 3D array 100 km in diameter. An 80-instrument passive array of intermediate and broadband sensors was active during our experiment. We recorded 19 borehole shots loaded in nominal 50-meter boreholes, 2 quarry shots, and 2 lake shots. The shots ranged in size from 50-5750 kg, with the most common shot size being 1 tonne. Prior to loading each shot-hole, we measured distances between shots and the nearest structure, typically un-reinforced mud-and-wood houses, occasionally concrete irrigation ditches and aqueducts. We then used semi-empirical formulae derived by Oriard (Hendron and Oriard, 1972) to calculate expected maximum and minimum bounds on ground velocity at these structures, and selected an appropriate shot size to keep the predicted velocity below the "threshold for cosmetic damage", or 2 inches per second, at the most vulnerable structure. The Oriard formulae are derived from measurements associated with blasting for mining and civil engineering purposes and may not accurately predict the ground velocity from the source depths and explosive type used in the EAGLE and other controlled-source experiments. A detailed, trace-by-trace analysis of maximum ground velocities at our closest seismographs can provide data that will be useful in planning future large-scale seismic experiments. Preliminary results from traces within 20 km of our borehole shots suggest that maximum recorded ground velocities were within or below the maximum-minimum range predicted by Oriard, and hence that larger shot sizes could have been used with acceptable risks. A lake shot fired at the optimum depth (84 m for a 1 tonne shot) produced ground velocities that exceeded the predicted maximum at a few recodrers. However, optimum-depth shots are typically a significant distance offshore (c. 2.3 km for our shot) because of the required depth, so are unlikely to present a hazard to onshore structures. A lake shot fired in a shallower lake at half the optimum depth did not produce ground-velocities that exceed the Oriard maximum. Although we fired shots within 100 m of an unreinforced concrete aqueduct, and within 200 m of poorly engineered native buildings in poor structural condition, no damage was recorded. Our "Texan" seismometers recorded only vertical component velocity, using 4.5 Hz geophones. After removal of the geophone response the peak vertical velocity is typically measured at about 3 Hz and occurs shortly after the first arrival, presumably due to surface waves (ground roll). We are currently extending our analysis to include data from broadband, three-component recorders.

  17. Predicting survival in AIDS: refining the model.

    PubMed

    Hutchinson, S J; Brettle, R P; Gore, S M

    1997-11-01

    We tested the validity of a previously-published AIDS staging system by examining AIDS-defining diseases (ADDs) and CD4 counts as prognostic factors for survival of the 248 AIDS patients in the Edinburgh City Hospital Cohort, of whom 56% were injecting drug-users (IDUs). Cox regression was used to model the proportionality of risk of death as the CD4 count declined and more ADDs were experienced, and dependence upon post-AIDS treatment. Using the system of Mocroft et al. (Lancet 1995; 346:12-17) to grade severity, our data were well enough modelled, but we suggest: (i) regrading of HIV dementia (RR 3.9, 95% CI 2.5-6.0), mainly attributed to the drug users, to a very severe ADD; (ii) reduction in risk from zidovudine (RR 0.7, 95% CI 0.5-1.0) during AIDS follow-up for patients starting treatment at or after AIDS diagnosis; (iii) improved management of first mild ADDs (from 1987-89 to 1994-95: 40% reduction in IDUs appearing with mild index diseases, and an approximate three-fold reduction in risk associated with a mild ADD). This study supports previous findings on the significance of ADDs and lowest CD4 count in predicting the lifetime of AIDS patients.

  18. A Genetic Algorithm and Fuzzy Logic Approach for Video Shot Boundary Detection

    PubMed Central

    Thounaojam, Dalton Meitei; Khelchandra, Thongam; Singh, Kh. Manglem; Roy, Sudipta

    2016-01-01

    This paper proposed a shot boundary detection approach using Genetic Algorithm and Fuzzy Logic. In this, the membership functions of the fuzzy system are calculated using Genetic Algorithm by taking preobserved actual values for shot boundaries. The classification of the types of shot transitions is done by the fuzzy system. Experimental results show that the accuracy of the shot boundary detection increases with the increase in iterations or generations of the GA optimization process. The proposed system is compared to latest techniques and yields better result in terms of F1score parameter. PMID:27127500

  19. Real-time dynamic range and signal to noise enhancement in beam-scanning microscopy by integration of sensor characteristics, data acquisition hardware, and statistical methods

    NASA Astrophysics Data System (ADS)

    Kissick, David J.; Muir, Ryan D.; Sullivan, Shane Z.; Oglesbee, Robert A.; Simpson, Garth J.

    2013-02-01

    Despite the ubiquitous use of multi-photon and confocal microscopy measurements in biology, the core techniques typically suffer from fundamental compromises between signal to noise (S/N) and linear dynamic range (LDR). In this study, direct synchronous digitization of voltage transients coupled with statistical analysis is shown to allow S/N approaching the theoretical maximum throughout an LDR spanning more than 8 decades, limited only by the dark counts of the detector on the low end and by the intrinsic nonlinearities of the photomultiplier tube (PMT) detector on the high end. Synchronous digitization of each voltage transient represents a fundamental departure from established methods in confocal/multi-photon imaging, which are currently based on either photon counting or signal averaging. High information-density data acquisition (up to 3.2 GB/s of raw data) enables the smooth transition between the two modalities on a pixel-by-pixel basis and the ultimate writing of much smaller files (few kB/s). Modeling of the PMT response allows extraction of key sensor parameters from the histogram of voltage peak-heights. Applications in second harmonic generation (SHG) microscopy are described demonstrating S/N approaching the shot-noise limit of the detector over large dynamic ranges.

  20. Short range shooting distance estimation using variable pressure SEM images of the surroundings of bullet holes in textiles.

    PubMed

    Hinrichs, Ruth; Frank, Paulo Ricardo Ost; Vasconcellos, M A Z

    2017-03-01

    Modifications of cotton and polyester textiles due to shots fired at short range were analyzed with a variable pressure scanning electron microscope (VP-SEM). Different mechanisms of fiber rupture as a function of fiber type and shooting distance were detected, namely fusing, melting, scorching, and mechanical breakage. To estimate the firing distance, the approximately exponential decay of GSR coverage as a function of radial distance from the entrance hole was determined from image analysis, instead of relying on chemical analysis with EDX, which is problematic in the VP-SEM. A set of backscattered electron images, with sufficient magnification to discriminate micrometer wide GSR particles, was acquired at different radial distances from the entrance hole. The atomic number contrast between the GSR particles and the organic fibers allowed to find a robust procedure to segment the micrographs into binary images, in which the white pixel count was attributed to GSR coverage. The decrease of the white pixel count followed an exponential decay, and it was found that the reciprocal of the decay constant, obtained from the least-square fitting of the coverage data, showed a linear dependence on the shooting distance. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  1. Non-Markovian spin-resolved counting statistics and an anomalous relation between autocorrelations and cross correlations in a three-terminal quantum dot

    NASA Astrophysics Data System (ADS)

    Luo, JunYan; Yan, Yiying; Huang, Yixiao; Yu, Li; He, Xiao-Ling; Jiao, HuJun

    2017-01-01

    We investigate the noise correlations of spin and charge currents through an electron spin resonance (ESR)-pumped quantum dot, which is tunnel coupled to three electrodes maintained at an equivalent chemical potential. A recursive scheme is employed with inclusion of the spin degrees of freedom to account for the spin-resolved counting statistics in the presence of non-Markovian effects due to coupling with a dissipative heat bath. For symmetric spin-up and spin-down tunneling rates, an ESR-induced spin flip mechanism generates a pure spin current without an accompanying net charge current. The stochastic tunneling of spin carriers, however, produces universal shot noises of both charge and spin currents, revealing the effective charge and spin units of quasiparticles in transport. In the case of very asymmetric tunneling rates for opposite spins, an anomalous relationship between noise autocorrelations and cross correlations is revealed, where super-Poissonian autocorrelation is observed in spite of a negative cross correlation. Remarkably, with strong dissipation strength, non-Markovian memory effects give rise to a positive cross correlation of the charge current in the absence of a super-Poissonian autocorrelation. These unique noise features may offer essential methods for exploiting internal spin dynamics and various quasiparticle tunneling processes in mesoscopic transport.

  2. Comparison of hematologic measurements between local and central laboratories: data from the BABY HUG trial.

    PubMed

    Kalpatthi, Ram; Thompson, Bruce; Lu, Ming; Wang, Winfred C; Patel, Niren; Kutlar, Abdullah; Howard, Thomas; Luchtman-Jones, Lori; Miller, Scott T

    2013-02-01

    To investigate the concordance of blood count indices measured locally and at a central laboratory. In a multi-center clinical trial of hydroxyurea therapy in infants with sickle cell anemia (BABY HUG), the concordance between blood count indices measured locally and at a central laboratory was investigated. Local laboratory measurements of neutrophil and monocyte counts were significantly higher (44% and 37%, respectively) compared to the central measurements (p<0.0001), and mean corpuscular volume (MCV) was higher centrally. Overnight shipping with processing delay causes spurious reductions in absolute neutrophil count (ANC) and absolute monocyte count (AMC) that may result in incorrect monitoring decisions in multicenter clinical trials. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. The Physics of Shot Towers

    ERIC Educational Resources Information Center

    Lipscombe, Trevor C.; Mungan, Carl E.

    2012-01-01

    In the late 18th and throughout the 19th century, lead shot for muskets was prepared by use of a shot tower. Molten lead was poured from the top of a tower and, during its fall, the drops became spherical under the action of surface tension. In this article, we ask and answer the question: "How does the size of the lead shot depend on the height…

  4. The Source Physics Experiments (SPE): A Physics-Based Approach to Discriminate Low-Yield Nuclear Events (Invited)

    NASA Astrophysics Data System (ADS)

    Snelson, C. M.; Chipman, V.; White, R. L.; Emmitt, R.; Townsend, M.

    2013-12-01

    Discriminating low-yield nuclear explosions is one of the current challenges in the field of monitoring and verification. Work is currently underway in Nevada to address this challenge by conducting a series of experiments using a physics-based approach. This has been accomplished by using a multifaceted, multi-disciplinary approach that includes a range of activities, from characterizing the shallow subsurface to acquiring new explosion data both in the near field (< 100 m from the source) to the far field (> 100 m to 10 s km from the source). The Source Physics Experiment (SPE) is a collaborative project between National Security Technologies, LLC, Lawrence Livermore National Laboratory, Los Alamos National Laboratory, Sandia National Laboratories, the Defense Threat Reduction Agency, and the Air Force Technical Applications Center. The goal of the SPE is to understand the transition of seismic energy from the near field to the far field; to understand the development of S-waves in explosives sources; and to understand how anisotropy controls seismic energy transmission and partitioning. To fully explore these problems, the SPE test series includes tests in both simple and complex geology cases. The current series is being conducted in a highly fractured granite body. This location was chosen, in part, because it was the location of previous nuclear tests in the same rock body and because generally the geology has been well characterized. In addition to historic data, high-resolution seismic reflection, cross-hole tomography, core samples, LIDAR, hyperspectral, and fracture mapping data have been acquired to further characterize and detect changes after each of the shot across the test bed. The complex geology series includes 7 planned shots using conventional explosives in the same shot hole surrounded by Continuous Reflectometry for Radius vs. Time Experiment (CORRTEX), Time of Arrival, Velocity of Detonation, down-hole accelerometers, surface accelerometers, infrasound, and a suite of seismic sensors of various frequency bands from the near field to the far field. This allows for the use of a single test bed in the granite instead of multiple test beds to obtain the same results. The shots are planned at various depths to obtain a Green's function, scaled depth-of-burial data, nominal depth-of-burial data and damage-zone data. Three shots have been executed to date and the fourth is planned for August 2013 as a 220 lb (100 kg) TNT equivalent shot at a depth of 315 ft (96 m). Over 400 data channels have been recorded on the first series of shots with high fidelity. Once the complex geology site data have been exploited, a new test bed will be developed in a simpler geology to test these physics-based models. Ultimately, the results from this project will provide the next advances in the science of monitoring to enable a physics-based predicative capability. This work was done by National Security Technologies, LLC, under Contract No. DE-AC52-06NA25946 with the U.S. Department of Energy. DOE/NV/25946--1835.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snelson, C. M., Chipman, V. D., White, R. L., Emmitt, R. F., Townsend, M. J., Barker, D., Lee, P.

    Understanding the changes in seismic energy as it travels from the near field to the far field is the ultimate goal in monitoring for explosive events of interest. This requires a clear understanding of explosion phenomenology as it relates to seismic, infrasound, and acoustic signals. Although there has been much progress in modeling these phenomena, this has been primarily based in the empirical realm. As a result, the logical next step in advancing the seismic monitoring capability of the United States is to conduct field tests that can expand the predictive capability of the physics-based modeling currently under development. Themore » Source Physics Experiment at the Nevada National Security Site (SPE-N) is the first step in this endeavor to link the empirically based with the physics-based modeling. This is a collaborative project between National Security Technologies (NSTec), Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Sandia National Laboratories (SNL), the Defense Threat Reduction Agency (DTRA), and the Air Force Technical Applications Center (AFTAC). The test series require both the simple and complex cases to fully characterize the problem, which is to understand the transition of seismic energy from the near field to the far field; to understand the development of S-waves in explosives sources; and how anisotropy controls seismic energy transmission and partitioning. The current series is being conducted in a granite body called the Climax Stock. This location was chosen for several reasons, including the fairly homogenous granite; the location of previous nuclear tests in the same rock body; and generally the geology has been well characterized. The simple geology series is planned for 7 shots using conventional explosives in the same shot hole surrounded by Continuous Reflectometry for Radius vs. Time Experiment (CORRTEX), Time of Arrival (TOA), Velocity of Detonation (VOD), down-hole accelerometers, surface accelerometers, infrasound, and a suite of seismic sensors of various frequency bands from the near field to the far field. This allows for the use of a single test bed in the simple geology case instead of multiple tests beds to obtain the same results. The shots are planned at various depths to obtain a Green’s function, scaled-depth of burial data, nominal depth of burial data and damage zone data. SPE1-N was conducted in May 2011 as a 220 lb (100 kg) TNT equivalent calibration shot at a depth of 180 ft (55 m). SPE2-N was conducted in October 2011 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m). SPE3-N was conducted in July 2012 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m) in the damaged zone. Over 400 data channels were recorded for each of these shots and data recovery was about 95% with high signal to noise ratio. Once the simple geology site data has been utilized, a new test bed will be developed in a complex geology site to test these physics based models. Ultimately, the results from this project will provide the next advances in the science of monitoring to enable a physics-based predicative capability.« less

  6. Development of a single-shot CCD-based data acquisition system for time-resolved X-ray photoelectron spectroscopy at an X-ray free-electron laser facility

    PubMed Central

    Oura, Masaki; Wagai, Tatsuya; Chainani, Ashish; Miyawaki, Jun; Sato, Hiromi; Matsunami, Masaharu; Eguchi, Ritsuko; Kiss, Takayuki; Yamaguchi, Takashi; Nakatani, Yasuhiro; Togashi, Tadashi; Katayama, Tetsuo; Ogawa, Kanade; Yabashi, Makina; Tanaka, Yoshihito; Kohmura, Yoshiki; Tamasaku, Kenji; Shin, Shik; Ishikawa, Tetsuya

    2014-01-01

    In order to utilize high-brilliance photon sources, such as X-ray free-electron lasers (XFELs), for advanced time-resolved photoelectron spectroscopy (TR-PES), a single-shot CCD-based data acquisition system combined with a high-resolution hemispherical electron energy analyzer has been developed. The system’s design enables it to be controlled by an external trigger signal for single-shot pump–probe-type TR-PES. The basic performance of the system is demonstrated with an offline test, followed by online core-level photoelectron and Auger electron spectroscopy in ‘single-shot image’, ‘shot-to-shot image (image-to-image storage or block storage)’ and ‘shot-to-shot sweep’ modes at soft X-ray undulator beamline BL17SU of SPring-8. In the offline test the typical repetition rate for image-to-image storage mode has been confirmed to be about 15 Hz using a conventional pulse-generator. The function for correcting the shot-to-shot intensity fluctuations of the exciting photon beam, an important requirement for the TR-PES experiments at FEL sources, has been successfully tested at BL17SU by measuring Au 4f photoelectrons with intentionally controlled photon flux. The system has also been applied to hard X-ray PES (HAXPES) in ‘ordinary sweep’ mode as well as shot-to-shot image mode at the 27 m-long undulator beamline BL19LXU of SPring-8 and also at the SACLA XFEL facility. The XFEL-induced Ti 1s core-level spectrum of La-doped SrTiO3 is reported as a function of incident power density. The Ti 1s core-level spectrum obtained at low power density is consistent with the spectrum obtained using the synchrotron source. At high power densities the Ti 1s core-level spectra show space-charge effects which are analysed using a known mean-field model for ultrafast electron packet propagation. The results successfully confirm the capability of the present data acquisition system for carrying out the core-level HAXPES studies of condensed matter induced by the XFEL. PMID:24365935

  7. Shot-to-shot reproducibility of a self-magnetically insulated ion diode.

    PubMed

    Pushkarev, A I; Isakova, Yu I; Khailov, I P

    2012-07-01

    In this paper we present the analysis of shot to shot reproducibility of the ion beam which is formed by a self-magnetically insulated ion diode with an explosive emission graphite cathode. The experiments were carried out with the TEMP-4M accelerator operating in double-pulse mode: the first pulse is of negative polarity (300-500 ns, 100-150 kV), and this is followed by a second pulse of positive polarity (150 ns, 250-300 kV). The ion current density was 10-70 A/cm(2) depending on the diode geometry. The beam was composed from carbon ions (80%-85%) and protons. It was found that shot to shot variation in the ion current density was about 35%-40%, whilst the diode voltage and current were comparatively stable with the variation limited to no more than 10%. It was shown that focusing of the ion beam can improve the stability of the ion current generation and reduces the variation to 18%-20%. In order to find out the reason for the shot-to-shot variation in ion current density we examined the statistical correlation between the current density of the accelerated beam and other measured characteristics of the diode, such as the accelerating voltage, total current, and first pulse duration. The correlation between the ion current density measured simultaneously at different positions within the cross-section of the beam was also investigated. It was shown that the shot-to-shot variation in ion current density is mainly attributed to the variation in the density of electrons diffusing from the drift region into the A-K gap.

  8. Reducing Pb poisoning in birds and Pb exposure in game meat consumers: the dual benefit of effective Pb shot regulation.

    PubMed

    Mateo, Rafael; Vallverdú-Coll, Núria; López-Antia, Ana; Taggart, Mark A; Martínez-Haro, Monica; Guitart, Raimon; Ortiz-Santaliestra, Manuel E

    2014-02-01

    The use of lead (Pb) ammunition in the form of shot pellets has been identified as a Pb exposure risk in wildlife and their human consumers. We explore the hypothesis that Pb shot ban enforcement reduces the risk of avian Pb poisoning as well as Pb exposure in game meat consumers. We assessed compliance with a partial ban on Pb shot commencing in 2003 by examination of 937 waterbirds harvested by hunters between 2007 and 2012 in the Ebro delta (Spain). Prevalence of Pb shot ingestion was determined, as were Pb concentrations in liver and muscle tissue to evaluate the potential for Pb exposure in game meat consumers. Hunted birds with only embedded Pb shot (no steel) declined from 26.9% in 2007-08 to <2% over the following three hunting seasons after ban reinforcement. Pb shot ingestion in mallards decreased from a pre-ban value of 30.2% to 15.5% in the post-ban period. Liver Pb levels were predominantly defined by the presence of ingested shot, whereas muscle levels were defined by the presence of both ingested and embedded shot. Only 2.5% of mallard muscle tissue had Pb levels above European Union regulations for meat (0.1μg/g wet weight) in the 2008-09 season, when Pb shot ingestion prevalence was also at a minimum (5.1%). Effective restrictions in Pb ammunition use have a dual benefit since this reduces Pb exposure for game meat consumers due to embedded ammunition as well as reducing Pb poisoning in waterbirds. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Optimization of the prescription isodose line for Gamma Knife radiosurgery using the shot within shot technique.

    PubMed

    Johnson, Perry B; Monterroso, Maria I; Yang, Fei; Mellon, Eric

    2017-11-25

    This work explores how the choice of prescription isodose line (IDL) affects the dose gradient, target coverage, and treatment time for Gamma Knife radiosurgery when a smaller shot is encompassed within a larger shot at the same stereotactic coordinates (shot within shot technique). Beam profiles for the 4, 8, and 16 mm collimator settings were extracted from the treatment planning system and characterized using Gaussian fits. The characterized data were used to create over 10,000 shot within shot configurations by systematically changing collimator weighting and choice of prescription IDL. Each configuration was quantified in terms of the dose gradient, target coverage, and beam-on time. By analyzing these configurations, it was found that there are regions of overlap in target size where a higher prescription IDL provides equivalent dose fall-off to a plan prescribed at the 50% IDL. Furthermore, the data indicate that treatment times within these regions can be reduced by up to 40%. An optimization strategy was devised to realize these gains. The strategy was tested for seven patients treated for 1-4 brain metastases (20 lesions total). For a single collimator setting, the gradient in the axial plane was steepest when prescribed to the 56-63% (4 mm), 62-70% (8 mm), and 77-84% (16 mm) IDL, respectively. Through utilization of the optimization technique, beam-on time was reduced by more than 15% in 16/20 lesions. The volume of normal brain receiving 12 Gy or above also decreased in many cases, and in only one instance increased by more than 0.5 cm 3 . This work demonstrates that IDL optimization using the shot within shot technique can reduce treatment times without degrading treatment plan quality.

  10. Optimizing Controlling-Value-Based Power Gating with Gate Count and Switching Activity

    NASA Astrophysics Data System (ADS)

    Chen, Lei; Kimura, Shinji

    In this paper, a new heuristic algorithm is proposed to optimize the power domain clustering in controlling-value-based (CV-based) power gating technology. In this algorithm, both the switching activity of sleep signals (p) and the overall numbers of sleep gates (gate count, N) are considered, and the sum of the product of p and N is optimized. The algorithm effectively exerts the total power reduction obtained from the CV-based power gating. Even when the maximum depth is kept to be the same, the proposed algorithm can still achieve power reduction approximately 10% more than that of the prior algorithms. Furthermore, detailed comparison between the proposed heuristic algorithm and other possible heuristic algorithms are also presented. HSPICE simulation results show that over 26% of total power reduction can be obtained by using the new heuristic algorithm. In addition, the effect of dynamic power reduction through the CV-based power gating method and the delay overhead caused by the switching of sleep transistors are also shown in this paper.

  11. Optimization of single shot 3D breath-hold non-enhanced MR angiography of the renal arteries.

    PubMed

    Tan, Huan; Koktzoglou, Ioannis; Glielmi, Christopher; Galizia, Mauricio; Edelman, Robert R

    2012-05-19

    Cardiac and navigator-gated, inversion-prepared non-enhanced magnetic resonance angiography techniques can accurately depict the renal arteries without the need for contrast administration. However, the scan time and effectiveness of navigator-gated techniques depend on the subject respiratory pattern, which at times results in excessively prolonged scan times or suboptimal image quality. A single-shot 3D magnetization-prepared steady-state free precession technique was implemented to allow the full extent of the renal arteries to be depicted within a single breath-hold. Technical optimization of the breath-hold technique was performed with fourteen healthy volunteers. An alternative magnetization preparation scheme was tested to maximize inflow signal. Quantitative and qualitative comparisons were made between the breath-hold technique and the clinically accepted navigator-gated technique in both volunteers and patients on a 1.5 T scanner. The breath-hold technique provided an average of seven fold reduction in imaging time, without significant loss of image quality. Comparable single-to-noise and contrast-to-noise ratios of intra- and extra-renal arteries were found between the breath-hold and the navigator-gated techniques in volunteers. Furthermore, the breath-hold technique demonstrated good image quality for diagnostic purposes in a small number of patients in a pilot study. The single-shot, breath-hold technique offers an alternative to navigator-gated methods for non-enhanced renal magnetic resonance angiography. The initial results suggest a potential supplementary clinical role for the breath-hold technique in the evaluation of suspected renal artery diseases.

  12. SunShot 2030 for Photovoltaics (PV): Envisioning a Low-cost PV Future

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, Wesley J.; Frew, Bethany A.; Gagnon, Pieter J.

    In this report we summarize the implications, impacts, and deployment potential of reaching the SunShot 2030 targets for the electricity system in the contiguous United States. We model 25 scenarios of the U.S. power sector using the Regional Energy Deployment Systems (ReEDS) and Distributed Generation (dGen) capacity expansion models. The scenarios cover a wide range of sensitivities to capture future uncertainties relating to fuel prices, retirements, renewable energy capital costs, and load growth. We give special attention to the potential for storage costs to also rapidly decline due to its large synergies with low-cost solar. The ReEDS and dGen modelsmore » project utility- and distributed-scale power sector evolution, respectively, for the United States. Both models have been designed with special emphasis on capturing the unique traits of renewable energy, including variability and grid integration requirements. Across the suite of scenarios modeled, we find that reaching the SunShot 2030 target has the potential to lead to significant capacity additions of PV in the United States. By 2050, PV penetration levels are projected to reach 28-46 percent of total generation. If storage also sees significant reductions in cost, then the 2050 solar penetration levels could reach 41-64 percent. PV deployment is projected to occur in all of the lower 48 states, though the specific deployment level is scenario dependent. The growth in PV is projected to be dominated by utility-scale systems, but the actual mix between utility and distributed systems could ultimately vary depending on how policies, system costs, and rate structures evolve.« less

  13. Renal denervation for resistant hypertension using an irrigated radiofrequency balloon: 12-month results from the Renal Hypertension Ablation System (RHAS) trial.

    PubMed

    Ormiston, John A; Watson, Timothy; van Pelt, Niels; Stewart, Ralph; Stewart, James T; White, Jonathon M; Doughty, Robert N; Stewart, Fiona; Macdonald, Rhona; Webster, Mark W I

    2013-05-20

    Renal denervation using the point-by-point application of radiofrequency energy delivered by the first-generation Symplicity system is effective in lowering office blood pressure but may be time-consuming. The OneShot Renal Denervation System with a balloon-mounted spiral electrode potentially shortens and simplifies the procedure. This study is a hypothesis-generating first-in-human study to assess feasibility, and to provide preliminary efficacy and safety data. Eligible patients had a baseline office systolic blood pressure ≥160 mmHg (or ≥150 mmHg for diabetics) and were on two or more antihypertensive medications. Nine patients were enrolled. The primary endpoint, the insertion of the OneShot balloon into each renal artery and the delivery of radiofrequency energy, was achieved in 8/9 (89%) of patients. The one failure (the first patient) was due to generator high-impedance safety shut-off threshold set too low for humans. Adverse events were minor. No patient developed renal artery stenosis. Baseline BP was 185.67 ± 18.7 mmHg and the reductions at 1, 3, 6 and 12 months were 30.1 ± 13.6 (p=0.0004), 34.2 ± 20.2 (p=0.002), 33.6 ± 32.2 (p=0.021) and 30.6 ± 22.0 (p=0.019). The OneShot renal denervation system successfully delivered radiofrequency energy to the renal arteries in a short and straightforward procedure. Australian New Zealand Clinical Trials Registry - URL: anzctr.org.au. Trial identification: ACTRN12611000987965.

  14. Short communication: Inactivation of microbial contaminants in raw milk La Serena cheese by high-pressure treatments.

    PubMed

    Arqués, J L; Garde, S; Gaya, P; Medina, M; Nuñez, M

    2006-03-01

    La Serena cheese, a Spanish variety made from Merino ewes' raw milk, has a high pH value, low salt content, and high moisture, conditions that are all favorable for growth and survival of contaminating microorganisms, including pathogens. To improve its microbiological quality and safety, high-pressure treatments at 300 or 400 MPa for 10 min at 10 degrees C were applied to 2 batches of La Serena cheese on d 2 or 50 of ripening. Cheese treated on d 2 at 300 MPa showed viable aerobic counts that were 0.99 log units lower than those for control cheese on d 3 and showed counts of enterococci, coagulase-positive staphylococci, gram-negative bacteria, and coliforms that were 2.05, 0.49, 3.14, and 4.13 log units lower, respectively, than control cheese. For cheese treated on d 2 at 400 MPa, the respective reductions in counts were 2.02, 2.68, 1.45, 3.96, and 5.50 log units. On d 60, viable aerobic counts in cheese treated on d 50 at 300 MPa were 0.50 log units lower than those in control cheese, and counts of enterococci, gram-negative bacteria, and coliforms were 1.37, 2.30, and 4.85 log units lower, respectively. For cheese treated on d 50 at 400 MPa, the respective reductions in counts were 1.29, 1.98, 4.47, and > 5 log units. High-pressure treatments at 300 or 400 MPa on d 2 or 50 reduced significantly the counts of undesirable microorganisms, improving the microbiological quality and safety of La Serena cheese immediately after treatment and at the end of the ripening period.

  15. Immunizations - diabetes

    MedlinePlus

    ... In the lungs ( pneumonia ) You need at least one shot. A second shot may be needed if you ... given to healthy people 6 months or older. One type of shot is injected into a muscle (often the upper ...

  16. Cases of death caused by gas or warning firearms.

    PubMed

    Rothschild, M A; Maxeiner, H; Schneider, V

    1994-01-01

    Five cases of lethal injuries caused by gas or warning firearms are discussed. In one suicide case a modified weapon (elongated barrel) and steel bullets were used to fire a shot into the head, the bullets lodged in the skull and lethal bleeding resulted. In the other cases conventional gas weapons without evidence of alteration were used for contact shots; injuries were caused by the effect of propelling powder gases. Two of these cases were suicides (temporal contact shot and back of the neck contact shot), one was an accident (inguinal contact shot with lethal bleeding), and one was an attack by another person with a contact shot against the neck with bilateral tears of the hypopharynx. After successful surgery, a delayed death occurred 12 days later caused by bleeding into the airways from the ruptured external carotid artery.

  17. Sex hormone-dependent tRNA halves enhance cell proliferation in breast and prostate cancers.

    PubMed

    Honda, Shozo; Loher, Phillipe; Shigematsu, Megumi; Palazzo, Juan P; Suzuki, Ryusuke; Imoto, Issei; Rigoutsos, Isidore; Kirino, Yohei

    2015-07-21

    Sex hormones and their receptors play critical roles in the development and progression of the breast and prostate cancers. Here we report that a novel type of transfer RNA (tRNA)-derived small RNA, termed Sex HOrmone-dependent TRNA-derived RNAs (SHOT-RNAs), are specifically and abundantly expressed in estrogen receptor (ER)-positive breast cancer and androgen receptor (AR)-positive prostate cancer cell lines. SHOT-RNAs are not abundantly present in ER(-) breast cancer, AR(-) prostate cancer, or other examined cancer cell lines from other tissues. ER-dependent accumulation of SHOT-RNAs is not limited to a cell culture system, but it also occurs in luminal-type breast cancer patient tissues. SHOT-RNAs are produced from aminoacylated mature tRNAs by angiogenin-mediated anticodon cleavage, which is promoted by sex hormones and their receptors. Resultant 5'- and 3'-SHOT-RNAs, corresponding to 5'- and 3'-tRNA halves, bear a cyclic phosphate (cP) and an amino acid at the 3'-end, respectively. By devising a "cP-RNA-seq" method that is able to exclusively amplify and sequence cP-containing RNAs, we identified the complete repertoire of 5'-SHOT-RNAs. Furthermore, 5'-SHOT-RNA, but not 3'-SHOT-RNA, has significant functional involvement in cell proliferation. These results have unveiled a novel tRNA-engaged pathway in tumorigenesis of hormone-dependent cancers and implicate SHOT-RNAs as potential candidates for biomarkers and therapeutic targets.

  18. Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes

    NASA Astrophysics Data System (ADS)

    Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng

    2016-09-01

    Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ˜400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.

  19. Spectraplakins promote microtubule-mediated axonal growth by functioning as structural MAPs and EB1-dependent +TIPs

    PubMed Central

    Alves-Silva, J.; Sánchez-Soriano, N.; Beaven, R.; Klein, M.; Parkin, J.; Millard, T.H.; Bellen, H. J; Venken, K. J.T.; Ballestrem, C.; Kammerer, R.A.; Prokop, A.

    2013-01-01

    The correct outgrowth of axons is essential for the development and regeneration of nervous systems. Axon growth is primarily driven by microtubules. Key regulators of microtubules in this context are the spectraplakins, a family of evolutionarily conserved actin-microtubule linkers. Loss of function of the mouse spectraplakin ACF7 or of its close Drosophila homologue Short stop/Shot similarly cause severe axon shortening and microtubule disorganisation. How spectraplakins perform these functions is not known. Here we show that axonal growth promoting roles of Shot require interaction with EB1 (End binding protein) at polymerising plus ends of microtubules. We show that binding of Shot to EB1 requires SxIP motifs in Shot’s carboxyterminal tail (Ctail), mutations of these motifs abolish Shot functions in axonal growth, loss of EB1 function phenocopies Shot loss, and genetic interaction studies reveal strong functional links between Shot and EB1 in axonal growth and microtubule organisation. In addition, we report that Shot localises along microtubule shafts and stabilises them against pharmacologically induced depolymerisation. This function is EB1-independent but requires net positive charges within Ctail which essentially contribute to the microtubule shaft association of Shot. Therefore, spectraplakins are true members of two important classes of neuronal microtubule regulating proteins: +TIPs (plus end regulators) and structural MAPs (microtubule associated proteins). From our data we deduce a model that relates the different features of the spectraplakin carboxy-terminus to the two functions of Shot during axonal growth. PMID:22764224

  20. Sex hormone-dependent tRNA halves enhance cell proliferation in breast and prostate cancers

    PubMed Central

    Honda, Shozo; Loher, Phillipe; Shigematsu, Megumi; Palazzo, Juan P.; Suzuki, Ryusuke; Imoto, Issei; Rigoutsos, Isidore; Kirino, Yohei

    2015-01-01

    Sex hormones and their receptors play critical roles in the development and progression of the breast and prostate cancers. Here we report that a novel type of transfer RNA (tRNA)-derived small RNA, termed Sex HOrmone-dependent TRNA-derived RNAs (SHOT-RNAs), are specifically and abundantly expressed in estrogen receptor (ER)-positive breast cancer and androgen receptor (AR)-positive prostate cancer cell lines. SHOT-RNAs are not abundantly present in ER− breast cancer, AR− prostate cancer, or other examined cancer cell lines from other tissues. ER-dependent accumulation of SHOT-RNAs is not limited to a cell culture system, but it also occurs in luminal-type breast cancer patient tissues. SHOT-RNAs are produced from aminoacylated mature tRNAs by angiogenin-mediated anticodon cleavage, which is promoted by sex hormones and their receptors. Resultant 5′- and 3′-SHOT-RNAs, corresponding to 5′- and 3′-tRNA halves, bear a cyclic phosphate (cP) and an amino acid at the 3′-end, respectively. By devising a “cP-RNA-seq” method that is able to exclusively amplify and sequence cP-containing RNAs, we identified the complete repertoire of 5′-SHOT-RNAs. Furthermore, 5′-SHOT-RNA, but not 3′-SHOT-RNA, has significant functional involvement in cell proliferation. These results have unveiled a novel tRNA-engaged pathway in tumorigenesis of hormone-dependent cancers and implicate SHOT-RNAs as potential candidates for biomarkers and therapeutic targets. PMID:26124144

  1. Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes.

    PubMed

    Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng

    2016-09-01

    Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ∼400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.

  2. Using a situation awareness approach to determine decision-making behaviour in squash.

    PubMed

    Murray, Stafford; James, Nic; Perš, Janez; Mandeljc, Rok; Vučković, Goran

    2018-06-01

    Situation awareness (SA) refers to the awareness of all relevant sources of information, an ability to synthesise this information using domain knowledge gained from past experiences and the ability to physically respond to a situation. Expert-novice differences have been widely reported in decision-making in complex situations although determining the small differences in expert behaviour are more elusive. This study considered how expert squash players use SA to decide on what shot to play. Matches at the 2010 (n = 14) and 2011 (n = 27) Rowe British Grand Prix were recorded and processed using Tracker software. Shot type, ball location, players' positions on court and movement parameters between the time an opponent played a shot prior to the player's shot to the time of the opponent's following shot were captured 25 times per second. Six SA clusters were named to relate to the outcome of a shot ranging from a defensive shot played under pressure to create time to an attempted winner played under no pressure with the opponent out of position. This new methodology found fine-grained SA differences in expert behaviour, even for the same shot type played from the same court area, beyond the usual expert-novice differences.

  3. Analysis of radiation exposure, Third Marine Corps Provisional Atomic Exercise Brigade. Exercise Desert Rock VI, Operation Teapot. Technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goetz, J.; Klemm, J.; Ortlieb, E.

    The radiation dose is reconstructed for 3d MCPAEB personnel participating in exercises involving helicopter-lifted assaults in conjunction with Shot Bee of Operation Teapot, Exercise Desert Rock VI. Brigade personnel were exposed to initial radiation while in trenches at the time of the Shot Bee detonation. They were also exposed to residual radiation from an earlier test shot (Shot Turk) during their subsequent maneuvers and to residual radiation from Shot Bee during an inspection of equipment displays. The calculated total gamma doses to the bulk of the participating troops range from about 0.57-0.85 rem.

  4. Indicator 1.04: Number of native forest-associated species

    Treesearch

    C. H. Flather; M. S Knowles; C. H. Sieg

    2011-01-01

    This indicator provides information on the health of forest ecosystems through the number of native forest-associated species. Because one of the more general signs of ecosystem stress is a reduction in the variety of organisms inhabiting a given locale, species counts are often used in assessing ecosystem well-being. The count of forest-associated species in a region...

  5. What You Can Expect with a Cortisone Shot

    MedlinePlus

    ... should avoid before your cortisone shot. What you can expect During the cortisone shot Your doctor might ... ll then be positioned so that your doctor can easily insert the needle. The area around the ...

  6. Investigation of ultra low-dose scans in the context of quantum-counting clinical CT

    NASA Astrophysics Data System (ADS)

    Weidinger, T.; Buzug, T. M.; Flohr, T.; Fung, G. S. K.; Kappler, S.; Stierstorfer, K.; Tsui, B. M. W.

    2012-03-01

    In clinical computed tomography (CT), images from patient examinations taken with conventional scanners exhibit noise characteristics governed by electronics noise, when scanning strongly attenuating obese patients or with an ultra-low X-ray dose. Unlike CT systems based on energy integrating detectors, a system with a quantum counting detector does not suffer from this drawback. Instead, the noise from the electronics mainly affects the spectral resolution of these detectors. Therefore, it does not contribute to the image noise in spectrally non-resolved CT images. This promises improved image quality due to image noise reduction in scans obtained from clinical CT examinations with lowest X-ray tube currents or obese patients. To quantify the benefits of quantum counting detectors in clinical CT we have carried out an extensive simulation study of the complete scanning and reconstruction process for both kinds of detectors. The simulation chain encompasses modeling of the X-ray source, beam attenuation in the patient, and calculation of the detector response. Moreover, in each case the subsequent image preprocessing and reconstruction is modeled as well. The simulation-based, theoretical evaluation is validated by experiments with a novel prototype quantum counting system and a Siemens Definition Flash scanner with a conventional energy integrating CT detector. We demonstrate and quantify the improvement from image noise reduction achievable with quantum counting techniques in CT examinations with ultra-low X-ray dose and strong attenuation.

  7. Spectrometer for shot-to-shot photon energy characterization in the multi-bunch mode of the free electron laser at Hamburg

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palutke, S., E-mail: steffen.palutke@desy.de; Wurth, W.; Deutsches Elekronen Synchrotron

    The setup and first results from commissioning of a fast online photon energy spectrometer for the vacuum ultraviolet free electron laser at Hamburg (FLASH) at DESY are presented. With the use of the latest advances in detector development, the presented spectrometer reaches readout frequencies up to 1 MHz. In this paper, we demonstrate the ability to record online photon energy spectra on a shot-to-shot base in the multi-bunch mode of FLASH. Clearly resolved shifts in the mean wavelength over the pulse train as well as shot-to-shot wavelength fluctuations arising from the statistical nature of the photon generating self-amplified spontaneous emissionmore » process have been observed. In addition to an online tool for beam calibration and photon diagnostics, the spectrometer enables the determination and selection of spectral data taken with a transparent experiment up front over the photon energy of every shot. This leads to higher spectral resolutions without the loss of efficiency or photon flux by using single-bunch mode or monochromators.« less

  8. Facts about Vitamin K Deficiency Bleeding

    MedlinePlus

    ... K shot into a muscle in the thigh. One shot given just after birth will protect your baby ... easily preventable with just a single vitamin K shot at birth. References 1. Zipursky A. Prevention of vitamin K deficiency bleeding ...

  9. Protect Your Child against Hib Disease

    MedlinePlus

    ... 4 months old. With both vaccines, children need one booster shot when they are 12 through 15 months old. ... series of Hib shots as babies and need one booster shot when they are 12 through 15 months old. ...

  10. How to give a heparin shot

    MedlinePlus

    ... Ask your provider for a chart. Keep your shots 1 inch (2.5 centimeters) away from scars and 2 inches (5 centimeters) away from your navel. DO NOT put a shot in a spot that is bruised, swollen, or ...

  11. Removal of Retained Lead Shot Through Laparoscopic Appendectomy

    PubMed Central

    Lloyd, D. M.

    2003-01-01

    We describe a patient presenting with lead shot in his appendix. A plain radiograph of his lumbar spine was performed for back pain, and an incidental finding of lead shot retained within the appendix was seen. Lead shot in the appendix is associated with appendicitis, and 2 cases have been reported of lead intoxication. We suggest that an elective laparoscopic appendectomy should be offered to patients as a possible management option. PMID:12856854

  12. A compact and versatile tender X-ray single-shot spectrometer for online XFEL diagnostics.

    PubMed

    Rehanek, Jens; Milne, Christopher J; Szlachetko, Jakub; Czapla-Masztafiak, Joanna; Schneider, Jörg; Huthwelker, Thomas; Borca, Camelia N; Wetter, Reto; Patthey, Luc; Juranić, Pavle

    2018-01-01

    One of the remaining challenges for accurate photon diagnostics at X-ray free-electron lasers (FELs) is the shot-to-shot, non-destructive, high-resolution characterization of the FEL pulse spectrum at photon energies between 2 keV and 4 keV, the so-called tender X-ray range. Here, a spectrometer setup is reported, based on the von Hamos geometry and using elastic scattering as a fingerprint of the FEL-generated spectrum. It is capable of pulse-to-pulse measurement of the spectrum with an energy resolution (ΔE/E) of 10 -4 , within a bandwidth of 2%. The Tender X-ray Single-Shot Spectrometer (TXS) will grant to experimental scientists the freedom to measure the spectrum in a single-shot measurement, keeping the transmitted beam undisturbed. It will enable single-shot reconstructions for easier and faster data analysis.

  13. Measurement of shot noise in magnetic tunnel junction and its utilization for accurate system calibration

    NASA Astrophysics Data System (ADS)

    Tamaru, S.; Kubota, H.; Yakushiji, K.; Fukushima, A.; Yuasa, S.

    2017-11-01

    This work presents a technique to calibrate the spin torque oscillator (STO) measurement system by utilizing the whiteness of shot noise. The raw shot noise spectrum in a magnetic tunnel junction based STO in the microwave frequency range is obtained by first subtracting the baseline noise, and then excluding the field dependent mag-noise components reflecting the thermally excited spin wave resonances. As the shot noise is guaranteed to be completely white, the total gain of the signal path should be proportional to the shot noise spectrum obtained by the above procedure, which allows for an accurate gain calibration of the system and a quantitative determination of each noise power. The power spectral density of the shot noise as a function of bias voltage obtained by this technique was compared with a theoretical calculation, which showed excellent agreement when the Fano factor was assumed to be 0.99.

  14. Efficacy of the addition of salicylic acid to clindamycin and benzoyl peroxide combination for acne vulgaris.

    PubMed

    Akarsu, Sevgi; Fetil, Emel; Yücel, Filiz; Gül, Eylem; Güneş, Ali T

    2012-05-01

    Clindamycin phosphate (CDP), benzoyl peroxide (BPO) and salicylic acid (SA) are known to be effective acne therapy agents depending on their anti-inflammatory and comedolytic properties. The purpose of this study was to investigate the efficacy and tolerability of the addition of SA treatment to CDP and BPO (SA and CDP + BPO) and compare it with CDP + BPO in patients with mild to moderate facial acne vulgaris. Forty-nine patients were enrolled in a 12 week prospective, single-blind, randomized, comparative clinical study. Efficacy was assessed by lesion counts, global improvement, quality of life index and measurements of skin barrier functions. Local side effects were also evaluated. Both combinations were effective in reducing total lesion (TL), inflammatory lesion (IL) and non-inflammatory lesion (NIL) counts. There were statistically significant differences between treatment groups for reductions in NIL counts beyond 2 weeks, IL counts and TL counts throughout the all study weeks, and global improvement scores evaluated by patients and investigator at the end of the study in favor of SA and CDP + BPO treatment when compared to CDP + BPO treatment. Both combinations significantly decreased stratum corneum hydration, although skin sebum values decreased with SA and CDP + BPO treatment. These combinations were also well tolerated except significantly higher frequency of mild to moderate transient dryness in patients applied SA and CDP + BPO. The addition of SA to CDP + BPO treatment demonstrated significantly better and faster results in terms of reductions in acne lesion counts and well tolerated except for higher frequency of mild to moderate transient dryness. © 2011 Japanese Dermatological Association.

  15. Pain Control

    MedlinePlus

    ... inside the cheek or under the tongue. ■■ Injections (shots): There are two different kinds of shots: • Under the skin: Medicine is placed just under ... Subcutaneous (sub-kyu-TAY-nee-yus) injection : A shot under the skin. Sublingual : Under the tongue. Supplements : ...

  16. Your Guide to Medicare's Preventive Services

    MedlinePlus

    ... often is it covered? Most people only need one shot once in their lifetime. A different, second shot, ... Welcome to Medicare” preventive visit Medicare covers a one-time ... on important screenings and shots and to talk with your doctor about your ...

  17. 35. INTERIOR VIEW, WHEELBRATORFRYE SHOT PEENER FOR REMOVAL OF RUST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35. INTERIOR VIEW, WHEELBRATOR-FRYE SHOT PEENER FOR REMOVAL OF RUST AND SCALE; NOTE TOOLS ARE TUMBLED WITH BLASTED WITH LEAD SHOT TO CLEAN SURFACES - Warwood Tool Company, Foot of Nineteenth Street, Wheeling, Ohio County, WV

  18. Hermes III endpoint energy calculation from photonuclear activation of 197Au and 58Ni foils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parzyck, Christopher Thomas

    2014-09-01

    A new process has been developed to characterize the endpoint energy of HERMES III on a shot-to-shot basis using standard dosimetry tools from the Sandia Radiation Measurements Laboratory. Photonuclear activation readings from nickel and gold foils are used in conjunction with calcium fluoride thermoluminescent dosimeters to derive estimated electron endpoint energies for a series of HERMES shots. The results are reasonably consistent with the expected endpoint voltages on those shots.

  19. One-shot percutaneous electrical nerve stimulation vs. transcutaneous electrical nerve stimulation for low back pain: comparison of therapeutic effects.

    PubMed

    Hsieh, Ru-Lan; Lee, Wen-Chung

    2002-11-01

    To investigate the therapeutic effects of one shot of low-frequency percutaneous electrical nerve stimulation one shot of transcutaneous electrical nerve stimulation in patients with low back pain. In total, 133 low back pain patients were recruited for this randomized, control study. Group 1 patients received medication only. Group 2 patients received medication plus one shot of percutaneous electrical nerve stimulation. Group 3 patients received medication plus one shot of transcutaneous electrical nerve stimulation. Therapeutic effects were measured using a visual analog scale, body surface score, pain pressure threshold, and the Quebec Back Pain Disability Scale. Immediately after one-shot treatment, the visual analog scale improved 1.53 units and the body surface score improved 3.06 units in the percutaneous electrical nerve stimulation group. In the transcutaneous electrical nerve stimulation group, the visual analog scale improved 1.50 units and the body surface score improved 3.98 units. The improvements did not differ between the two groups. There were no differences in improvement at 3 days or 1 wk after the treatment among the three groups. Simple one-shot treatment with percutaneous electrical nerve stimulation or transcutaneous electrical nerve stimulation provided immediate pain relief for low back pain patients. One-shot transcutaneous electrical nerve stimulation treatment is recommended due to the rarity of side effects and its convenient application.

  20. High resolution human diffusion tensor imaging using 2-D navigated multi-shot SENSE EPI at 7 Tesla

    PubMed Central

    Jeong, Ha-Kyu; Gore, John C.; Anderson, Adam W.

    2012-01-01

    The combination of parallel imaging with partial Fourier acquisition has greatly improved the performance of diffusion-weighted single-shot EPI and is the preferred method for acquisitions at low to medium magnetic field strength such as 1.5 or 3 Tesla. Increased off-resonance effects and reduced transverse relaxation times at 7 Tesla, however, generate more significant artifacts than at lower magnetic field strength and limit data acquisition. Additional acceleration of k-space traversal using a multi-shot approach, which acquires a subset of k-space data after each excitation, reduces these artifacts relative to conventional single-shot acquisitions. However, corrections for motion-induced phase errors are not straightforward in accelerated, diffusion-weighted multi-shot EPI because of phase aliasing. In this study, we introduce a simple acquisition and corresponding reconstruction method for diffusion-weighted multi-shot EPI with parallel imaging suitable for use at high field. The reconstruction uses a simple modification of the standard SENSE algorithm to account for shot-to-shot phase errors; the method is called Image Reconstruction using Image-space Sampling functions (IRIS). Using this approach, reconstruction from highly aliased in vivo image data using 2-D navigator phase information is demonstrated for human diffusion-weighted imaging studies at 7 Tesla. The final reconstructed images show submillimeter in-plane resolution with no ghosts and much reduced blurring and off-resonance artifacts. PMID:22592941

  1. Ground Reaction Forces and Throwing Performance in Elite and Novice Players in Two Types of Handball Shot

    PubMed Central

    Rousanoglou, Elissavet; Noutsos, Konstantinos; Bayios, Ioannis; Boudolos, Konstantinos

    2014-01-01

    The purpose of this study was to examine the differences in the ground reaction force (GRF) patterns between elite and novice players during two types of handball shots, as well as the relationships between throwing performance and the GRF variables. Ball velocity and throwing accuracy were measured during jump shots and 3-step shots performed by 15 elite and 15 novice players. The GRF pattern was recorded for the vertical and the anterior-posterior GRF components (Kistler forceplate type-9281, 750Hz). One-way ANOVA was used for the group differences and the Pearson coefficient for the correlation between throwing performance and GRF variables (SPSS 21.0, p ≤ 0.05). The elite players performed better in both types of shot. Both groups developed consistent and similar GRF patterns, except for the novices’ inconsistent Fz pattern in the 3-step shot. The GRF variables differed significantly between groups in the 3-step shot (p ≤ 0.05). Significant correlations were found only for ball velocity and predominantly for the novice players during the 3-step shot (p ≤ 0.05). The results possibly highlight a shortage in the novice ability to effectively reduce their forward momentum so as to provide a stable base of support for the momentum transfer up the kinetic chain, a situation that may predispose athletes to injury. PMID:25031672

  2. Ground reaction forces and throwing performance in elite and novice players in two types of handball shot.

    PubMed

    Rousanoglou, Elissavet; Noutsos, Konstantinos; Bayios, Ioannis; Boudolos, Konstantinos

    2014-03-27

    The purpose of this study was to examine the differences in the ground reaction force (GRF) patterns between elite and novice players during two types of handball shots, as well as the relationships between throwing performance and the GRF variables. Ball velocity and throwing accuracy were measured during jump shots and 3-step shots performed by 15 elite and 15 novice players. The GRF pattern was recorded for the vertical and the anterior-posterior GRF components (Kistler forceplate type-9281, 750Hz). One-way ANOVA was used for the group differences and the Pearson coefficient for the correlation between throwing performance and GRF variables (SPSS 21.0, p ≤ 0.05). The elite players performed better in both types of shot. Both groups developed consistent and similar GRF patterns, except for the novices' inconsistent Fz pattern in the 3-step shot. The GRF variables differed significantly between groups in the 3-step shot (p ≤ 0.05). Significant correlations were found only for ball velocity and predominantly for the novice players during the 3-step shot (p ≤ 0.05). The results possibly highlight a shortage in the novice ability to effectively reduce their forward momentum so as to provide a stable base of support for the momentum transfer up the kinetic chain, a situation that may predispose athletes to injury.

  3. A large surface photomultiplier based on SiPMs

    NASA Astrophysics Data System (ADS)

    Barbarino, Giancarlo; de Asmundis, Riccardo; De Rosa, Gianfranca; Vivolo, Daniele; Mollo, Carlos Maximiliano

    2013-10-01

    Light detection through photosensitive devices represents one of the key issues for a large variety of experiments. In the recent years, Silicon PhotoMultipliers (SiPMs) based on limited Geiger-mode avalanche have been extensively studied in view of their future applications. However, their use is strongly limited by their small sensitive surfaces and by the fact that any increment in the surface turns out into an increase of the dark count rate. In the present work we describe the dark count rate reduction obtained by using a FPGA-based logical circuit for fast pre-processing of pulses from a 3×3 matrix of SiPMs. The prototype we developed supports two SiPMs: we show that a rate reduction from 6.6 Mcps (Mega counts per second) down to 0.436 Mcps at the lowest threshold (0.5 photon-equivalent) and from 1.2 kcps down to 0.02 cps for the highest threshold (3.5 photon-equivalent) is obtainable.

  4. Application of DNA Chip Scanning Technology for Automatic Detection of Chlamydia trachomatis and Chlamydia pneumoniae Inclusions

    PubMed Central

    Bogdanov, Anita; Endrész, Valeria; Urbán, Szabolcs; Lantos, Ildikó; Deák, Judit; Burián, Katalin; Önder, Kamil; Ayaydin, Ferhan; Balázs, Péter

    2014-01-01

    Chlamydiae are obligate intracellular bacteria that propagate in the inclusion, a specific niche inside the host cell. The standard method for counting chlamydiae is immunofluorescent staining and manual counting of chlamydial inclusions. High- or medium-throughput estimation of the reduction in chlamydial inclusions should be the basis of testing antichlamydial compounds and other drugs that positively or negatively influence chlamydial growth, yet low-throughput manual counting is the common approach. To overcome the time-consuming and subjective manual counting, we developed an automatic inclusion-counting system based on a commercially available DNA chip scanner. Fluorescently labeled inclusions are detected by the scanner, and the image is processed by ChlamyCount, a custom plug-in of the ImageJ software environment. ChlamyCount was able to measure the inclusion counts over a 1-log-unit dynamic range with a high correlation to the theoretical counts. ChlamyCount was capable of accurately determining the MICs of the novel antimicrobial compound PCC00213 and the already known antichlamydial antibiotics moxifloxacin and tetracycline. ChlamyCount was also able to measure the chlamydial growth-altering effect of drugs that influence host-bacterium interaction, such as gamma interferon, DEAE-dextran, and cycloheximide. ChlamyCount is an easily adaptable system for testing antichlamydial antimicrobials and other compounds that influence Chlamydia-host interactions. PMID:24189259

  5. Get Your Flu Shot!| NIH MedlinePlus the Magazine

    MedlinePlus

    ... of this page please turn Javascript on. Feature: Flu Shot Get Your Flu Shot! Past Issues / Winter 2011 Table of Contents ... failure, or lung disease "For the 2010–2011 flu season, the flu vaccine provides protection against the ...

  6. Allergy Shots: Could They Help Your Allergies?

    MedlinePlus

    ... do I have to get? Most people get 1 or 2 shots each week at first. After about 6 months ... Teens, Procedures & Devices, Your Health ResourcesTags: allergy, allergy shots April 1, 1998 Copyright © American Academy of Family Physicians This ...

  7. What Vaccinations Do You Need?

    MedlinePlus

    ... antibodies. This is why some vaccines might need one shot, while others need more than one shot. In some cases, a blood test is used ... Depending on the vaccine, you may need only one shot to protect you for life. Other vaccines may ...

  8. X-ray analog pixel array detector for single synchrotron bunch time-resolved imaging.

    PubMed

    Koerner, Lucas J; Gruner, Sol M

    2011-03-01

    Dynamic X-ray studies can reach temporal resolutions limited by only the X-ray pulse duration if the detector is fast enough to segregate synchrotron pulses. An analog integrating pixel array detector with in-pixel storage and temporal resolution of around 150 ns, sufficient to isolate pulses, is presented. Analog integration minimizes count-rate limitations and in-pixel storage captures successive pulses. Fundamental tests of noise and linearity as well as high-speed laser measurements are shown. The detector resolved individual bunch trains at the Cornell High Energy Synchrotron Source at levels of up to 3.7 × 10(3) X-rays per pixel per train. When applied to turn-by-turn X-ray beam characterization, single-shot intensity measurements were made with a repeatability of 0.4% and horizontal oscillations of the positron cloud were detected.

  9. X-ray analog pixel array detector for single synchrotron bunch time-resolved imaging

    PubMed Central

    Koerner, Lucas J.; Gruner, Sol M.

    2011-01-01

    Dynamic X-ray studies can reach temporal resolutions limited by only the X-ray pulse duration if the detector is fast enough to segregate synchrotron pulses. An analog integrating pixel array detector with in-pixel storage and temporal resolution of around 150 ns, sufficient to isolate pulses, is presented. Analog integration minimizes count-rate limitations and in-pixel storage captures successive pulses. Fundamental tests of noise and linearity as well as high-speed laser measurements are shown. The detector resolved individual bunch trains at the Cornell High Energy Synchrotron Source at levels of up to 3.7 × 103 X-rays per pixel per train. When applied to turn-by-turn X-ray beam characterization, single-shot intensity measurements were made with a repeatability of 0.4% and horizontal oscillations of the positron cloud were detected. PMID:21335901

  10. New recording package for VACM provides sensor flexibility

    USGS Publications Warehouse

    Strahle, William J.; Worrilow, S. E.; Fucile, S. E.; Martini, Marinna A.

    1994-01-01

    For the past three decades, the VACM has been a standard for ocean current measurements. A VACM is a true vector-averaging instrument that computes north and east current vectors and averages temperature continuously over a specified interval. It keeps a running total of rotor counts, and records one-shot samples of compass, vane position and time. Adding peripheral sensors to the data stream was easy. In today's economy, it seems imperative that operational centers concentrate on upgrading present inventory rather than purchasing newer instruments that often fall short of the flexible measurement platforms with high data capacities required by most researchers today. PCMCIA cards are rapidly becoming an industry standard with a wide range of storage capacities. By upgrading the VACM to a PCMCIA storage system with a flexible microprocessor, the VACM should continue to be a viable instrument into the next century

  11. Grainsize evolution and differential comminution in an experimental regolith

    NASA Technical Reports Server (NTRS)

    Horz, F.; Cintala, M.; See, T.

    1984-01-01

    The comminution of planetary surfaces by exposure to continuous meteorite bombardment was simulated by impacting the same fragmental gabbro target 200 times. The role of comminution and in situ gardening of planetary regoliths was addressed. Mean grain size continuously decreased with increasing shot number. Initially it decreased linearly with accumulated energy, but at some stage comminution efficiency started to decrease gradually. Point counting techniques, aided by the electron microprobe for mineral identification, were performed on a number of comminution products. Bulk chemical analyses of specific grain size fractions were also carried out. The finest sizes ( 10 microns) display generally the strongest enrichment/depletion factors. Similar, if not exactly identical, trends are reported from lunar soils. It is, therefore, not necessarily correct to explain the chemical characteristics of various grain sizes via different admixtures of materials from distant source terrains. Differential comminution of local source rocks may be the dominating factor.

  12. Introduction: From "The Popularization of Science through Film" to "The Public Understanding of Science".

    PubMed

    Vidal, Fernando

    2018-03-01

    Science in film, and usual equivalents such as science on film or science on screen, refer to the cinematographic representation, staging, and enactment of actors, information, and processes involved in any aspect or dimension of science and its history. Of course, boundaries are blurry, and films shot as research tools or documentation also display science on screen. Nonetheless, they generally count as scientific film, and science in and on film or screen tend to designate productions whose purpose is entertainment and education. Moreover, these two purposes are often combined, and inherently concern empirical, methodological, and conceptual challenges associated with popularization, science communication, and the public understanding of science. It is in these areas that the notion of the deficit model emerged to designate a point of view and a mode of understanding, as well as a set of practical and theoretical problems about the relationship between science and the public.

  13. PARPs and ADP-Ribosylation: 50 Years … and Counting.

    PubMed

    Kraus, W Lee

    2015-06-18

    Over 50 years ago, the discovery of poly(ADP-ribose) (PAR) set a new field of science in motion-the field of poly(ADP-ribosyl) transferases (PARPs) and ADP-ribosylation. The field is still flourishing today. The diversity of biological processes now known to require PARPs and ADP-ribosylation was practically unimaginable even two decades ago. From an initial focus on DNA damage detection and repair in response to genotoxic stresses, the field has expanded to include the regulation of chromatin structure, gene expression, and RNA processing in a wide range of biological systems, including reproduction, development, aging, stem cells, inflammation, metabolism, and cancer. This special focus issue of Molecular Cell includes a collection of three Reviews, three Perspectives, and a SnapShot, which together summarize the current state of the field and suggest where it may be headed. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Experimental chemotherapy in horses infected with benzimidazole-resistant small strongyles.

    PubMed

    Britt, D P; Clarkson, M J

    1988-08-27

    The presence of benzimidazole-resistant strains of equine small strongyles was confirmed in horses at two properties in north west England by a series of faecal egg counts and larval cultures after treatment with mebendazole. A trail formulation of mebendazole in combination with piperazine citrate gave greater reductions in faecal egg counts than mebendazole alone but was much less effective than pyrantel embonate or dichlorvos.

  15. Reduction of Escherichia coli 0157:H7 in shredded iceberg lettuce by chlorination and gamma irradiation

    NASA Astrophysics Data System (ADS)

    Foley, D. M.; Dufour, A.; Rodriguez, L.; Caporaso, F.; Prakash, A.

    2002-03-01

    Lettuce was inoculated with a six-strain cocktail of acid-adapted Escherichia coli 0157:H7 at a level of 1×10 7 CFU/g. Following chlorination at 200 μg/ml, the lettuce was irradiated at 0.15, 0.38, or 0.55 kGy using a 60Co source. Survival of E. coli 0157:H7, aerobic mesophiles and yeast and molds were measured over a period of 10 days. For quality analysis, chlorinated lettuce was subjected to irradiation at 0.33 and 0.53 kGy and stored at 1.0°C, 4.0°C or 7.0°C. Changes in texture and color were determined by instrumental means and changes in flavor, odor, and visual quality were determined by sensory testing. Chlorination plus irradiation at 0.55 kGy produced a 5.4-log reduction in E. coli 0157:H7 levels. Chlorination alone reduced the E. coli 0157:H7 counts by 1-2 logs. Irradiation at 0.55 kGy was also effective in reducing standard plate counts and yeast and mold counts. Irradiation at this level did not cause softening of lettuce and sensory attributes were not adversely affected. In general, appearance and flavor were affected more by the length of storage than by temperature conditions. The 5+log reduction in E. coli counts and lack of adverse effects on sensory attributes indicate that low-dose irradiation can improve the safety and shelf-life of fresh-cut iceberg lettuce for retail sale or food service.

  16. Liquid nitrogen for the treatment of actinic keratosis: a longitudinal assessment.

    PubMed

    Ianhez, Mayra; Miot, Hélio Amante; Bagatin, Edileia

    2014-08-01

    Cryosurgery with liquid nitrogen is one of the most used treatments for actinic keratosis. We aimed to study the effectiveness of two consecutive sessions of cryosurgery for actinic keratosis and investigate factors associated with its therapeutic success. Hence, we conducted a longitudinal study including 92 patients of both sexes, aged 50-75 years with 5-50 actinic keratosis on the face and forearms, who underwent cryosurgery and treatment with sunscreen SPF 30, at baseline and after 120 days. The lesions were counted in duplicate by the same examiner before the start of treatment and after 120 (N=92) and 300 days (N=33), represented by their medians and quartiles and compared using the generalized linear mixed effects model (negative binomial). Treatment behavior was investigated in relation to sex, age, education, skin type, smoking, sun exposure at work and the use of aspirin, anti-inflammatory and angiotensin-converting enzyme inhibitors. There was a significant reduction in the actinic keratosis count on the face and forearms (p<0.05). Our results confirmed the effectiveness of cryosurgery for actinic keratosis, with a 57% reduction in the number, and size of the lesions. Higher education levels (p=0.02) and less sun exposure at work (p=0.02) independently promoted a significant reduction in the actinic keratosis count. Different population groups showed characteristic responses to the treatment, which may be explained by the degree of adherence to the use of photoprotection. In two sessions, cryosurgery with liquid nitrogen reduced the actinic keratosis count. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Supercritical Carbon Dioxide Power Generation System Definition: Concept Definition and Capital Cost Estimate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoddard, Larry; Galluzzo, Geoff; Andrew, Daniel

    The Department of Energy’s (DOE’s) Office of Renewable Power (ORP) has been tasked to provide effective program management and strategic direction for all of the DOE’s Energy Efficiency & Renewable Energy’s (EERE’s) renewable power programs. The ORP’s efforts to accomplish this mission are aligned with national energy policies, DOE strategic planning, EERE’s strategic planning, Congressional appropriation, and stakeholder advice. ORP is supported by three renewable energy offices, of which one is the Solar Energy Technology Office (SETO) whose SunShot Initiative has a mission to accelerate research, development and large scale deployment of solar technologies in the United States. SETO hasmore » a goal of reducing the cost of Concentrating Solar Power (CSP) by 75 percent of 2010 costs by 2020 to reach parity with base-load energy rates, and 30 percent further reductions by 2030. The SunShot Initiative is promoting the implementation of high temperature CSP with thermal energy storage allowing generation during high demand hours. The SunShot Initiative has funded significant research and development work on component testing, with attention to high temperature molten salts, heliostats, receiver designs, and high efficiency high temperature supercritical CO 2 (sCO2) cycles. DOE retained Black & Veatch to support SETO’s SunShot Initiative for CSP solar power tower technology in the following areas: 1. Concept definition, including costs and schedule, of a flexible test facility to be used to test and prove components in part to support financing. 2. Concept definition, including costs and schedule, of an integrated high temperature molten salt (MS) facility with thermal energy storage and with a supercritical CO 2 cycle generating approximately 10MWe. 3. Concept definition, including costs and schedule, of an integrated high temperature falling particle facility with thermal energy storage and with a supercritical CO 2 cycle generating approximately 10MWe. This report addresses the concept definition of the sCO2 power generation system, a sub-set of items 2 and 3 above. Other reports address the balance of items 1 to 3 above as well as the MS/sCO2 integrated 10MWe facility, Item 2.« less

  18. On the Path to SunShot - The Environmental and Public Health Benefits of Achieving High Penetrations of Solar Energy in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiser, Ryan; Mai, Trieu; Millstein, Dev

    Monetizing the environmental health benefits of solar could add ~3.5¢/kWh to the value of solar energy (see Wiser et al. 2016). The monetary impacts due to environmental degradation and public health impacts seem far removed from the apparent “sticker price” of electricity. Yet quantifying these impacts is essential to understanding the true costs and benefits of solar and conventional generating technologies. Compared with fossil fuel generators, PV and CSP produce far lower lifecycle levels of greenhouse gas (GHG) emissions and harmful pollutants including fine particular matter (PM2.5), sulfur dioxide (SO2), and nitrogen oxides (NOx). Achieving the SunShot-level solar deployment targets—14%more » of U.S. electricity demand met by solar in 2030 and 27% in 2050—could reduce cumulative power-sector GHG emissions by 10% between 2015 and 2050, resulting in savings of $238–$252 billion. This is equivalent to 2.0–2.2 cents per kilowatt-hour of solar installed (¢/kWh-solar). Similarly, realizing these levels of solar deployment could reduce cumulative power-sector emissions of PM2.5 by 8%, SO2 by 9%, and NOx by 11% between 2015 and 2050. This could produce $167 billion in savings from lower future health and environmental damages, or 1.4¢/kWh-solar—while also preventing 25,000–59,000 premature deaths. To put this in perspective, the estimated 3.5¢/kWh-solar in benefits due to SunShot-level solar deployment is approximately equal to the additional LCOE reduction needed to make unsubsidized utility-scale solar competitive with conventional generators today. In addition, water savings from achieving the SunShot goals, could result in the 2015–2050 cumulative savings of 4% of total power-sector withdrawals and 9% of total power-sector consumption—a particularly important consideration for arid states where substantial solar will be deployed. Improving public health and the environment is but one aspect of solar’s many costs and benefits. Clearly, however, the assignment of value« less

  19. Potential Hazard to Human Health from Exposure to Fragments of Lead Bullets and Shot in the Tissues of Game Animals

    PubMed Central

    Pain, Deborah J.; Cromie, Ruth L.; Newth, Julia; Brown, Martin J.; Crutcher, Eric; Hardman, Pippa; Hurst, Louise; Mateo, Rafael; Meharg, Andrew A.; Moran, Annette C.; Raab, Andrea; Taggart, Mark A.; Green, Rhys E.

    2010-01-01

    Background Lead is highly toxic to animals. Humans eating game killed using lead ammunition generally avoid swallowing shot or bullets and dietary lead exposure from this source has been considered low. Recent evidence illustrates that lead bullets fragment on impact, leaving small lead particles widely distributed in game tissues. Our paper asks whether lead gunshot pellets also fragment upon impact, and whether lead derived from spent gunshot and bullets in the tissues of game animals could pose a threat to human health. Methodology/Principal Findings Wild-shot gamebirds (6 species) obtained in the UK were X-rayed to determine the number of shot and shot fragments present, and cooked using typical methods. Shot were then removed to simulate realistic practice before consumption, and lead concentrations determined. Data from the Veterinary Medicines Directorate Statutory Surveillance Programme documenting lead levels in raw tissues of wild gamebirds and deer, without shot being removed, are also presented. Gamebirds containing ≥5 shot had high tissue lead concentrations, but some with fewer or no shot also had high lead concentrations, confirming X-ray results indicating that small lead fragments remain in the flesh of birds even when the shot exits the body. A high proportion of samples from both surveys had lead concentrations exceeding the European Union Maximum Level of 100 ppb w.w. (0.1 mg kg−1 w.w.) for meat from bovine animals, sheep, pigs and poultry (no level is set for game meat), some by several orders of magnitude. High, but feasible, levels of consumption of some species could result in the current FAO/WHO Provisional Weekly Tolerable Intake of lead being exceeded. Conclusions/Significance The potential health hazard from lead ingested in the meat of game animals may be larger than previous risk assessments indicated, especially for vulnerable groups, such as children, and those consuming large amounts of game. PMID:20436670

  20. Real-time inverse planning for Gamma Knife radiosurgery.

    PubMed

    Wu, Q Jackie; Chankong, Vira; Jitprapaikulsarn, Suradet; Wessels, Barry W; Einstein, Douglas B; Mathayomchan, Boonyanit; Kinsella, Timothy J

    2003-11-01

    The challenges of real-time Gamma Knife inverse planning are the large number of variables involved and the unknown search space a priori. With limited collimator sizes, shots have to be heavily overlapped to form a smooth prescription isodose line that conforms to the irregular target shape. Such overlaps greatly influence the total number of shots per plan, making pre-determination of the total number of shots impractical. However, this total number of shots usually defines the search space, a pre-requisite for most of the optimization methods. Since each shot only covers part of the target, a collection of shots in different locations and various collimator sizes selected makes up the global dose distribution that conforms to the target. Hence, planning or placing these shots is a combinatorial optimization process that is computationally expensive by nature. We have previously developed a theory of shot placement and optimization based on skeletonization. The real-time inverse planning process, reported in this paper, is an expansion and the clinical implementation of this theory. The complete planning process consists of two steps. The first step is to determine an optimal number of shots including locations and sizes and to assign initial collimator size to each of the shots. The second step is to fine-tune the weights using a linear-programming technique. The objective function is to minimize the total dose to the target boundary (i.e., maximize the dose conformity). Results of an ellipsoid test target and ten clinical cases are presented. The clinical cases are also compared with physician's manual plans. The target coverage is more than 99% for manual plans and 97% for all the inverse plans. The RTOG PITV conformity indices for the manual plans are between 1.16 and 3.46, compared to 1.36 to 2.4 for the inverse plans. All the inverse plans are generated in less than 2 min, making real-time inverse planning a reality.

  1. Potential hazard to human health from exposure to fragments of lead bullets and shot in the tissues of game animals.

    PubMed

    Pain, Deborah J; Cromie, Ruth L; Newth, Julia; Brown, Martin J; Crutcher, Eric; Hardman, Pippa; Hurst, Louise; Mateo, Rafael; Meharg, Andrew A; Moran, Annette C; Raab, Andrea; Taggart, Mark A; Green, Rhys E

    2010-04-26

    Lead is highly toxic to animals. Humans eating game killed using lead ammunition generally avoid swallowing shot or bullets and dietary lead exposure from this source has been considered low. Recent evidence illustrates that lead bullets fragment on impact, leaving small lead particles widely distributed in game tissues. Our paper asks whether lead gunshot pellets also fragment upon impact, and whether lead derived from spent gunshot and bullets in the tissues of game animals could pose a threat to human health. Wild-shot gamebirds (6 species) obtained in the UK were X-rayed to determine the number of shot and shot fragments present, and cooked using typical methods. Shot were then removed to simulate realistic practice before consumption, and lead concentrations determined. Data from the Veterinary Medicines Directorate Statutory Surveillance Programme documenting lead levels in raw tissues of wild gamebirds and deer, without shot being removed, are also presented. Gamebirds containing > or =5 shot had high tissue lead concentrations, but some with fewer or no shot also had high lead concentrations, confirming X-ray results indicating that small lead fragments remain in the flesh of birds even when the shot exits the body. A high proportion of samples from both surveys had lead concentrations exceeding the European Union Maximum Level of 100 ppb w.w. (0.1 mg kg(-1) w.w.) for meat from bovine animals, sheep, pigs and poultry (no level is set for game meat), some by several orders of magnitude. High, but feasible, levels of consumption of some species could result in the current FAO/WHO Provisional Weekly Tolerable Intake of lead being exceeded. The potential health hazard from lead ingested in the meat of game animals may be larger than previous risk assessments indicated, especially for vulnerable groups, such as children, and those consuming large amounts of game.

  2. Query by example video based on fuzzy c-means initialized by fixed clustering center

    NASA Astrophysics Data System (ADS)

    Hou, Sujuan; Zhou, Shangbo; Siddique, Muhammad Abubakar

    2012-04-01

    Currently, the high complexity of video contents has posed the following major challenges for fast retrieval: (1) efficient similarity measurements, and (2) efficient indexing on the compact representations. A video-retrieval strategy based on fuzzy c-means (FCM) is presented for querying by example. Initially, the query video is segmented and represented by a set of shots, each shot can be represented by a key frame, and then we used video processing techniques to find visual cues to represent the key frame. Next, because the FCM algorithm is sensitive to the initializations, here we initialized the cluster center by the shots of query video so that users could achieve appropriate convergence. After an FCM cluster was initialized by the query video, each shot of query video was considered a benchmark point in the aforesaid cluster, and each shot in the database possessed a class label. The similarity between the shots in the database with the same class label and benchmark point can be transformed into the distance between them. Finally, the similarity between the query video and the video in database was transformed into the number of similar shots. Our experimental results demonstrated the performance of this proposed approach.

  3. Detection of hidden shot balls in a gas-cooled turbine blade with an NRT gadolinium tagging method

    NASA Astrophysics Data System (ADS)

    Sim, Cheul Muu; Kim, Yi Kyung; Kim, TaeJoo; Lee, Kye Hong; Kim, Jeong Uk

    2009-06-01

    This report provides a preliminary insight into the benefits and effectiveness of neutron radiography in identifying alien materials, namely shot balls hidden in a turbine blade that are otherwise undetected using other methods. The detection of 0.2-mm-diameter shot balls in gas-cooled turbine blades is possible for thermal neutron radiography. A tagging processing is more useful for a distinctive image of newer turbine blades. Areas of concern for the tagging process include the solution concentration and the possibility of a slight washing of the blades. The location of the shot balls within the turbine blades tagged with Gd((2%, 5%)+water) was shown. Shot balls were placed externally on a turbine blade (F100-700, F100-200) surface in order to check for a dead zone from a surface examination. The image is produced from neutron radiography after a 5 min exposure time. When the blade is tagged with 2% and 5% Gd with slight washing, the shot can also be effectively seen on the SR-45 film. Shot balls are more obvious on a neutron image SR-45 film than an image plate or a DR film.

  4. Deep learning based beat event detection in action movie franchises

    NASA Astrophysics Data System (ADS)

    Ejaz, N.; Khan, U. A.; Martínez-del-Amor, M. A.; Sparenberg, H.

    2018-04-01

    Automatic understanding and interpretation of movies can be used in a variety of ways to semantically manage the massive volumes of movies data. "Action Movie Franchises" dataset is a collection of twenty Hollywood action movies from five famous franchises with ground truth annotations at shot and beat level of each movie. In this dataset, the annotations are provided for eleven semantic beat categories. In this work, we propose a deep learning based method to classify shots and beat-events on this dataset. The training dataset for each of the eleven beat categories is developed and then a Convolution Neural Network is trained. After finding the shot boundaries, key frames are extracted for each shot and then three classification labels are assigned to each key frame. The classification labels for each of the key frames in a particular shot are then used to assign a unique label to each shot. A simple sliding window based method is then used to group adjacent shots having the same label in order to find a particular beat event. The results of beat event classification are presented based on criteria of precision, recall, and F-measure. The results are compared with the existing technique and significant improvements are recorded.

  5. Heavy metals in flamingos (Phoenicopterus ruber) from Italian wetlands: The problem of ingestion of lead shot

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ancora, Stefania; Bianchi, Nicola; Leonzio, Claudio

    2008-06-15

    Waterbirds are exposed to many contaminants, including lead from ingestion of shot and fishing sinkers. Lead poisoning had never been reported in flamingos wintering in Italian wetlands. Our investigation stems from a case of four flamingos found dead in Tuscany in 2002 with numerous lead shot in their gizzards. We therefore considered other specimens found dead in different Italian wetlands. Many lead shot found in gizzards and lead tissue concentrations confirmed the hypothesis of lead poisoning in two of the seven specimens analysed: concentrations in liver, kidney, and bone were 361.3, 265.09, and 43.31 {mu}g/g d.w., respectively. Lead organotropism wasmore » typical of acute poisoning. Cadmium and mercury were also determined, and found to be in line with what little data are available on this species in the literature. Although Italy recently endorsed the African-Eurasian Waterbird Agreement (AEWA) prohibiting use of lead shot for hunting in wetlands, our results reveal a first case of lead shot poisoning in flamingos wintering in Italian wetlands. This evidence sounds a further warning of the problem of spent lead shot in countries where hunting in wetlands is not strictly regulated.« less

  6. Kinematic and kinetic analysis of overhand, sidearm and underhand lacrosse shot techniques.

    PubMed

    Macaulay, Charles A J; Katz, Larry; Stergiou, Pro; Stefanyshyn, Darren; Tomaghelli, Luciano

    2017-12-01

    Lacrosse requires the coordinated performance of many complex skills. One of these skills is shooting on the opponents' net using one of three techniques: overhand, sidearm or underhand. The purpose of this study was to (i) determine which technique generated the highest ball velocity and greatest shot accuracy and (ii) identify kinematic and kinetic variables that contribute to a high velocity and high accuracy shot. Twelve elite male lacrosse players participated in this study. Kinematic data were sampled at 250 Hz, while two-dimensional force plates collected ground reaction force data (1000 Hz). Statistical analysis showed significantly greater ball velocity for the sidearm technique than overhand (P < 0.001) and underhand (P < 0.001) techniques. No statistical difference was found for shot accuracy (P > 0.05). Kinematic and kinetic variables were not significantly correlated to shot accuracy or velocity across all shot types; however, when analysed independently, the lead foot horizontal impulse showed a negative correlation with underhand ball velocity (P = 0.042). This study identifies the technique with the highest ball velocity, defines kinematic and kinetic predictors related to ball velocity and provides information to coaches and athletes concerned with improving lacrosse shot performance.

  7. Single-shot spectroscopy of broadband Yb fiber laser

    NASA Astrophysics Data System (ADS)

    Suzuki, Masayuki; Yoneya, Shin; Kuroda, Hiroto

    2017-02-01

    We have experimentally reported on a real-time single-shot spectroscopy of a broadband Yb-doped fiber (YDF) laser which based on a nonlinear polarization evolution by using a time-stretched dispersive Fourier transformation technique. We have measured an 8000 consecutive single-shot spectra of mode locking and noise-like pulse (NLP), because our developed broadband YDF oscillator can individually operate the mode locking and NLP by controlling a pump LD power and angle of waveplates. A shot-to-shot spectral fluctuation was observed in NLP. For the investigation of pulse formation dynamics, we have measured the spectral evolution in an initial fluctuations of mode locked broadband YDF laser at an intracavity dispersion of 1500 and 6200 fs2 for the first time. In both case, a build-up time between cw and steady-state mode locking was estimated to be 50 us, the dynamics of spectral evolution between cw and mode locking, however, was completely different. A shot-to-shot strong spectral fluctuation, as can be seen in NLP spectra, was observed in the initial timescale of 20 us at the intracavity dispersion of 1500 fs2. These new findings would impact on understanding the birth of the broadband spectral formation in fiber laser oscillator.

  8. A treatment planning study to assess the feasibility of laser-driven proton therapy using a compact gantry design.

    PubMed

    Hofmann, Kerstin M; Masood, Umar; Pawelke, Joerg; Wilkens, Jan J

    2015-09-01

    Laser-driven proton acceleration is suggested as a cost- and space-efficient alternative for future radiation therapy centers, although the properties of these beams are fairly different compared to conventionally accelerated proton beams. The laser-driven proton beam is extremely pulsed containing a very high proton number within ultrashort bunches at low bunch repetition rates of few Hz and the energy spectrum of the protons per bunch is very broad. Moreover, these laser accelerated bunches are subject to shot-to-shot fluctuations. Therefore, the aim of this study was to investigate the feasibility of a compact gantry design for laser-driven proton therapy and to determine limitations to comply with. Based on a published gantry beam line design which can filter parabolic spectra from an exponentially decaying broad initial spectrum, a treatment planning study was performed on real patient data sets. All potential parabolic spectra were fed into a treatment planning system and numerous spot scanning proton plans were calculated. To investigate limitations in the fluence per bunch, the proton number of the initial spectrum and the beam width at patient entrance were varied. A scenario where only integer shots are delivered as well as an intensity modulation from shot to shot was studied. The resulting plans were evaluated depending on their dosimetric quality and in terms of required treatment time. In addition, the influence of random shot-to-shot fluctuations on the plan quality was analyzed. The study showed that clinically relevant dose distributions can be produced with the system under investigation even with integer shots. For small target volumes receiving high doses per fraction, the initial proton number per bunch must remain between 1.4 × 10(8) and 8.3 × 10(9) to achieve acceptable delivery times as well as plan qualities. For larger target volumes and standard doses per fraction, the initial proton number is even more restricted to stay between 1.4 × 10(9) and 2.9 × 10(9). The lowest delivery time that could be reached for such a case was 16 min for a 10 Hz system. When modulating the intensity from shot to shot, the delivery time can be reduced to 6 min for this scenario. Since the shot-to-shot fluctuations are of random nature, a compensation effect can be observed, especially for higher laser shot numbers. Therefore, a fluctuation of ± 30% within the proton number does not translate into a dosimetric deviation of the same size. However, for plans with short delivery times these fluctuations cannot cancel out sufficiently, even for ± 10% fluctuations. Under the analyzed terms, it is feasible to achieve clinically relevant dose distributions with laser-driven proton beams. However, to keep the delivery times of the proton plans comparable to conventional proton plans for typical target volumes, a device is required which can modulate the bunch intensity from shot to shot. From the laser acceleration point of view, the proton number per bunch must be kept under control as well as the reproducibility of the bunches.

  9. A treatment planning study to assess the feasibility of laser-driven proton therapy using a compact gantry design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hofmann, Kerstin M., E-mail: kerstin.hofmann@lrz.tu-muenchen.de; Wilkens, Jan J.; Masood, Umar

    Purpose: Laser-driven proton acceleration is suggested as a cost- and space-efficient alternative for future radiation therapy centers, although the properties of these beams are fairly different compared to conventionally accelerated proton beams. The laser-driven proton beam is extremely pulsed containing a very high proton number within ultrashort bunches at low bunch repetition rates of few Hz and the energy spectrum of the protons per bunch is very broad. Moreover, these laser accelerated bunches are subject to shot-to-shot fluctuations. Therefore, the aim of this study was to investigate the feasibility of a compact gantry design for laser-driven proton therapy and tomore » determine limitations to comply with. Methods: Based on a published gantry beam line design which can filter parabolic spectra from an exponentially decaying broad initial spectrum, a treatment planning study was performed on real patient data sets. All potential parabolic spectra were fed into a treatment planning system and numerous spot scanning proton plans were calculated. To investigate limitations in the fluence per bunch, the proton number of the initial spectrum and the beam width at patient entrance were varied. A scenario where only integer shots are delivered as well as an intensity modulation from shot to shot was studied. The resulting plans were evaluated depending on their dosimetric quality and in terms of required treatment time. In addition, the influence of random shot-to-shot fluctuations on the plan quality was analyzed. Results: The study showed that clinically relevant dose distributions can be produced with the system under investigation even with integer shots. For small target volumes receiving high doses per fraction, the initial proton number per bunch must remain between 1.4 × 10{sup 8} and 8.3 × 10{sup 9} to achieve acceptable delivery times as well as plan qualities. For larger target volumes and standard doses per fraction, the initial proton number is even more restricted to stay between 1.4 × 10{sup 9} and 2.9 × 10{sup 9}. The lowest delivery time that could be reached for such a case was 16 min for a 10 Hz system. When modulating the intensity from shot to shot, the delivery time can be reduced to 6 min for this scenario. Since the shot-to-shot fluctuations are of random nature, a compensation effect can be observed, especially for higher laser shot numbers. Therefore, a fluctuation of ±30% within the proton number does not translate into a dosimetric deviation of the same size. However, for plans with short delivery times these fluctuations cannot cancel out sufficiently, even for ±10% fluctuations. Conclusions: Under the analyzed terms, it is feasible to achieve clinically relevant dose distributions with laser-driven proton beams. However, to keep the delivery times of the proton plans comparable to conventional proton plans for typical target volumes, a device is required which can modulate the bunch intensity from shot to shot. From the laser acceleration point of view, the proton number per bunch must be kept under control as well as the reproducibility of the bunches.« less

  10. The effect of 1% chlorhexidine varnish and 40% xylitol solution on Streptococcus mutans and plaque accumulation in children.

    PubMed

    Simões Moraes, Renata; Modesto, Adriana; Regina Netto Dos Santos, Kátia; Drake, David

    2011-01-01

    The purpose of this study was to determine the effect of the association of 1% chlorhexidine varnish (CHX) and 40% xylitol solution (XYL) on Streptococcus mutans (SM) counts and plaque indices in 2- to 5-year-olds. Sixty-eight children were selected with medium levels (1 x 10³) to very high levels (>1 x 10⁵) of SM in the saliva. Subjects were divided into 4 groups of 17 children each: (1) CHX; (2) CHX+XYL; (3) XYL; and(4) 0.05% sodium fluoride (F). An assessment of SM levels and plaque indices was done on all children at baseline, 15 days, and at 1, 3, and 6 months. SM levels were determined by the spatula method. Although the reduction in SM counts in all groups was statistically significant, differences among groups were not observed, and the CHX and F groups seemed to show the greatest effect. Plaque reduction was observed in all groups, whereas statistically significant decreases among groups were not observed. One percent chlorhexidine varnish associated with 40% xylitol solution tested in the present study does not provide significant suppression of Streptococcus mutans counts and reduction of plaque accumulation at any follow-up time points.

  11. Efficacy of a topical application of Certifect® (fipronil 6.26% w/v, amitraz 7.48% w/v, (S)-methoprene 5.63% w/v) for the treatment of canine generalized demodicosis.

    PubMed

    Fourie, Josephus; Dumont, Pascal; Halos, Lénaïg; Beugnet, Frederic; Pollmeier, Matthias

    2013-01-01

    The efficacy of the treatment with Certifect ® (containing fipronil 6.26% w/v, amitraz 7.48% w/v, (S)-methoprene 5.63% w/v) applied topically was assessed in 18 dogs diagnosed with clinical generalized demodicosis. Three treatment regimens were compared over a 3-month period. Starting at Day 0, dogs were treated monthly (group 1) or every two weeks (group 2) with the combination of fipronil, amitraz, and (S)-methoprene or with monthly topical applications of the combination of amitraz and metaflumizone (group 3, reference treatment). Clinical examinations including deep skin scrapings were performed every month in order to evaluate the resolution of clinical signs and the reduction in mite counts. On Day 84, the percentage reduction of mite counts in group 1 was 99.8%, whereas no Demodex canis could be detected in groups 2 and 3 (i.e. 100% parasitological efficacy). As a result of the Demodex mite count reduction, the skin condition of the dogs improved significantly in all groups. This study illustrates, that both monthly and bi-weekly treatments with Certifect were effective in treating dogs with generalized demodicosis over a 3-month period. © J. Fourie et al., published by EDP Sciences, 2013.

  12. Efficacy of a topical application of Certifect® (fipronil 6.26% w/v, amitraz 7.48% w/v, (S)-methoprene 5.63% w/v) for the treatment of canine generalized demodicosis

    PubMed Central

    Fourie, Josephus; Dumont, Pascal; Halos, Lénaïg; Beugnet, Frederic; Pollmeier, Matthias

    2013-01-01

    The efficacy of the treatment with Certifect ® (containing fipronil 6.26% w/v, amitraz 7.48% w/v, (S)-methoprene 5.63% w/v) applied topically was assessed in 18 dogs diagnosed with clinical generalized demodicosis. Three treatment regimens were compared over a 3-month period. Starting at Day 0, dogs were treated monthly (group 1) or every two weeks (group 2) with the combination of fipronil, amitraz, and (S)-methoprene or with monthly topical applications of the combination of amitraz and metaflumizone (group 3, reference treatment). Clinical examinations including deep skin scrapings were performed every month in order to evaluate the resolution of clinical signs and the reduction in mite counts. On Day 84, the percentage reduction of mite counts in group 1 was 99.8%, whereas no Demodex canis could be detected in groups 2 and 3 (i.e. 100% parasitological efficacy). As a result of the Demodex mite count reduction, the skin condition of the dogs improved significantly in all groups. This study illustrates, that both monthly and bi-weekly treatments with Certifect were effective in treating dogs with generalized demodicosis over a 3-month period. PMID:24256940

  13. The effect of trigger point management by positional release therapy on tension type headache.

    PubMed

    Ghanbari, Ali; Rahimijaberi, Abbas; Mohamadi, Marzieh; Abbasi, Leila; Sarvestani, Fahimeh Kamali

    2012-01-01

    The aim of this study was to compare the effectiveness of trigger points' management by Positional Release Therapy (PRT) and routine medical therapy in treatment of Tension Type Headache. Tension Type Headache is the most frequent headache with the basis of myofascial and trigger point disorders. PRT is an indirect technique that treats trigger points. 30 Patients with active trigger points in cervical muscles entered to the study. They were randomly assigned to PRT or medical therapy group. Headache frequency, intensity and duration and tablet count were recorded by use of a daily headache diary. Sensitivity of trigger points was assessed by numeric pain intensity and by use of a digital force gauge (FG 5020). Both groups showed significant reduction in headache frequency and duration and tablet count after treatment phase. However, the reduction of study variables was persisted only in PRT group after follow up phase. There was no significant reduction in headache intensity, neither in PRT and nor in medication group. Sensitivity of trigger points was significantly reduced. In comparison of the two study groups, there was no significant difference in headache frequency, intensity, duration and tablet count (p> 0.05). Both procedures were equally effective according to the study. Thus, PRT can be a treatment choice for patients with T.T.H.

  14. On the Eigenstrain Application of Shot-peened Residual Stresses within a Crystal Plasticity Framework: Application to Ni-base Superalloy Specimens (Postprint)

    DTIC Science & Technology

    2015-07-08

    Compressive surface residual stresses can be applied via multi ple techniques (shot/gravity peening, low plasticity burnishing, laser shock peening...eigenstrains are used include internal stresses due to inclusions/particles or fibers [48], differences in coefficient of thermal expansion of different phases...residual stresses induced by shot peening [44,52 54], laser shock peening [55 61], and welding [62 66]. For shot peening analysis, the amount of residual

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hurricane, O. A.; Clark, D. S.

    The work is summarized from several perspectives: 1D simulation perspective: Post-shot models agree with yield data to within a factor of ~2 at low implosion velocities, but the models diverge from the data as the velocity and convergence ratio increase. 2D simulation perspective: Integrated hohlraum-capsule post-shot models agree with primary data for most implosions, but overpredict yield and DSR for a few of the highest velocity implosions. High-resolution 3D post-shot capsule-only modeling captures much of the delivered performance of the one shot currently simulated.

  16. Doubled full shot noise in quantum coherent superconductor-semiconductor junctions.

    PubMed

    Lefloch, F; Hoffmann, C; Sanquer, M; Quirion, D

    2003-02-14

    We performed low temperature shot noise measurements in superconductor (TiN) strongly disordered normal metal (heavily doped Si) weakly transparent junctions. We show that the conductance has a maximum due to coherent multiple Andreev reflections at low energy and that the shot noise is then twice the Poisson noise (S = 4eI). When the subgap conductance reaches its minimum at finite voltage the shot noise changes to the normal value (S = 2eI) due to a large quasiparticle contribution.

  17. Shot-to-shot reproducibility of a self-magnetically insulated ion diode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pushkarev, A. I.; Isakova, Yu. I.; Khailov, I. P.

    In this paper we present the analysis of shot to shot reproducibility of the ion beam which is formed by a self-magnetically insulated ion diode with an explosive emission graphite cathode. The experiments were carried out with the TEMP-4M accelerator operating in double-pulse mode: the first pulse is of negative polarity (300-500 ns, 100-150 kV), and this is followed by a second pulse of positive polarity (150 ns, 250-300 kV). The ion current density was 10-70 A/cm{sup 2} depending on the diode geometry. The beam was composed from carbon ions (80%-85%) and protons. It was found that shot to shotmore » variation in the ion current density was about 35%-40%, whilst the diode voltage and current were comparatively stable with the variation limited to no more than 10%. It was shown that focusing of the ion beam can improve the stability of the ion current generation and reduces the variation to 18%-20%. In order to find out the reason for the shot-to-shot variation in ion current density we examined the statistical correlation between the current density of the accelerated beam and other measured characteristics of the diode, such as the accelerating voltage, total current, and first pulse duration. The correlation between the ion current density measured simultaneously at different positions within the cross-section of the beam was also investigated. It was shown that the shot-to-shot variation in ion current density is mainly attributed to the variation in the density of electrons diffusing from the drift region into the A-K gap.« less

  18. Use and Perceptions of Caffeinated Energy Drinks and Energy Shots in Canada.

    PubMed

    Wiggers, Danielle; Reid, Jessica L; White, Christine M; Hammond, David

    2017-12-01

    In Canada, energy drinks and energy shots are currently classified and regulated differently (food and drugs versus natural health products, respectively), on the assumption that they are used and perceived differently. The current study examined potential differences in use and perceptions of energy drinks and shots. An online survey was conducted in 2015 using a national commercial online panel of youth and young adults aged 12-24 years (n=2,040 retained for analysis in 2016). Participants were randomized to view an image of an energy shot or drink, and were asked about 14 potential reasons for using the product. Past consumption of each product was also assessed. Chi-square and t-tests were conducted to examine differences in use and perceptions between products. Overall, 15.6% of respondents reported using both energy shots and drinks. Of all respondents, <1% had tried only energy shots, whereas 58.0% had tried only energy drinks. For each product, the most commonly reported reasons for use were "to stay awake" and "to increase concentration or alertness." Out of 14 potential reasons for use, respondents were significantly more likely to endorse seven of the reasons for energy drinks rather than shots; however, the magnitude of these differences was modest and the ordering of the reasons for use of each product was comparable. Despite differences in prevalence of ever-use of energy shots and drinks, consumption patterns and perceived reasons for using the products are similar. The findings provide little support for regulating energy shots differently than energy drinks. Copyright © 2017 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  19. Experimental Study on Fatigue Behaviour of Shot-Peened Open-Hole Steel Plates

    PubMed Central

    Wang, Zhi-Yu; Wang, Qing-Yuan; Cao, Mengqin

    2017-01-01

    This paper presents an experimental study on the fatigue behaviour of shot-peened open-hole plates with Q345 steel. The beneficial effects induced by shot peening on the fatigue life improvement are highlighted. The characteristic fatigue crack initiation and propagation modes of open-hole details under fatigue loading are revealed. The surface hardening effect brought by the shot peening is analyzed from the aspects of in-depth micro-hardness and compressive residual stress. The fatigue life results are evaluated and related design suggestions are made as a comparison with codified detail categories. In particular, a fracture mechanics theory-based method is proposed and demonstrated its validity in predicting the fatigue life of studied shot-peened open-hole details. PMID:28841160

  20. Reduction of Salmonella on chicken meat and chicken skin by combined or sequential application of lytic bacteriophage with chemical antimicrobials.

    PubMed

    Sukumaran, Anuraj T; Nannapaneni, Rama; Kiess, Aaron; Sharma, Chander Shekhar

    2015-08-17

    The effectiveness of recently approved Salmonella lytic bacteriophage preparation (SalmoFresh™) in reducing Salmonella in vitro and on chicken breast fillets was examined in combination with lauric arginate (LAE) or cetylpyridinium chloride (CPC). In another experiment, a sequential spray application of this bacteriophage (phage) solution on Salmonella inoculated chicken skin after a 20s dip in chemical antimicrobials (LAE, CPC, peracetic acid, or chlorine) was also examined in reducing Salmonella counts on chicken skin. The application of phage in combination with CPC or LAE reduced S. Typhimurium, S. Heidelberg, and S. Enteritidis up to 5 log units in vitro at 4 °C. On chicken breast fillets, phage in combination with CPC or LAE resulted in significant (p<0.05) reductions of Salmonella ranging from 0.5 to 1.3 log CFU/g as compared to control up to 7 days of refrigerated storage. When phage was applied sequentially with chemical antimicrobials, all the treatments resulted in significant reductions of Salmonella. The application of chlorine (30 ppm) and PAA (400 ppm) followed by phage spray (10(9)PFU/ml) resulted in highest Salmonella reductions of 1.6-1.7 and 2.2-2.5l og CFU/cm(2), respectively. In conclusion, the surface applications of phage in combination with LAE or CPC significantly reduced Salmonella counts on chicken breast fillets. However, higher reductions in Salmonella counts were achieved on chicken skin by the sequential application of chemical antimicrobials followed by phage spray. The sequential application of chlorine, PAA, and phage can provide additional hurdles to reduce Salmonella on fresh poultry carcasses or cut up parts. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Evaluation of the effects of ultraviolet light on bacterial contaminants inoculated into whole milk and colostrum, and on colostrum immunoglobulin G

    PubMed Central

    Pereira, R. V.; Bicalho, M. L.; Machado, V. S.; Lima, S.; Teixeira, A. G.; Warnick, L. D.; Bicalho, R. C.

    2015-01-01

    Raw milk and colostrum can harbor dangerous micro-organisms that can pose serious health risks for animals and humans. According to the USDA, more than 58% of calves in the United States are fed unpasteurized milk. The aim of this study was to evaluate the effect of UV light on reduction of bacteria in milk and colostrum, and on colostrum IgG. A pilot-scale UV light continuous (UVC) flow-through unit (45 J/cm2) was used to treat milk and colostrum. Colostrum and sterile whole milk were inoculated with Listeria innocua, Mycobacterium smegmatis, Salmonella serovar Typhimurium, Escherichia coli, Staphylococcus aureus, Streptococcus agalactiae, and Acinetobacter baumannii before being treated with UVC. During UVC treatment, samples were collected at 5 time points and bacteria were enumerated using selective media. The effect of UVC on IgG was evaluated using raw colostrum from a nearby dairy farm without the addition of bacteria. For each colostrum batch, samples were collected at several different time points and IgG was measured using ELISA. The UVC treatment of milk resulted in a significant final count (log cfu/mL) reduction of Listeria monocytogenes (3.2 ± 0.3 log cfu/mL reduction), Salmonella spp. (3.7 ± 0.2 log cfu/mL reduction), Escherichia coli (2.8 ± 0.2 log cfu/mL reduction), Staph. aureus (3.4 ± 0.3 log cfu/mL reduction), Streptococcus spp. (3.4 ± 0.4 log cfu/mL reduction), and A. baumannii (2.8 ± 0.2 log cfu/mL reduction). The UVC treatment of milk did not result in a significant final count (log cfu/mL) reduction for M. smegmatis (1.8 ± 0.5 log cfu/mL reduction). The UVC treatment of colostrum was significantly associated with a final reduction of bacterial count (log cfu/mL) of Listeria spp. (1.4 ± 0.3 log cfu/mL reduction), Salmonella spp. (1.0 ± 0.2 log cfu/mL reduction), and Acinetobacter spp. (1.1 ± 0.3 log cfu/mL reduction), but not of E. coli (0.5 ± 0.3 log cfu/mL reduction), Strep. agalactiae (0.8 ± 0.2 log cfu/mL reduction), and Staph. aureus (0.4 ± 0.2 log cfu/mL reduction). The UVC treatment of colostrum significantly decreased the IgG concentration, with an observed final mean IgG reduction of approximately 50%. Development of new methods to reduce bacterial contaminants in colostrum must take into consideration the barriers imposed by its opacity and organic components, and account for the incidental damage to IgG caused by manipulating colostrum. PMID:24582452

  2. Evaluation of anthelmintic activity of Iris hookeriana against gastrointestinal nematodes of sheep.

    PubMed

    Tariq, K A; Chishti, M Z; Ahmad, F; Shawl, A S; Tantray, M A

    2008-06-01

    The objective of this study was to evaluate the anthelmintic efficacy of Iris hookeriana Linn. rhizome against gastrointestinal nematodes of sheep. A worm motility inhibition assay was used for in vitro study and a faecal egg count reduction assay was used for an in vivo study. The in vitro study revealed anthelmintic effects of crude aqueous extracts and crude ethanolic extracts on live Trichuris ovis worms (P < or = 0.05) as evident from their paralysis and/or death at 8 h after exposure. The aqueous extracts of I. hookeriana resulted in a mean worm motility inhibition of 54.0%, while ethanolic extracts resulted in a mean worm motility inhibition of 84.6%. The mean mortality index of aqueous extracts was 0.55, while for ethanolic extracts it was 0.85. The lethal concentration 50 for aqueous extracts was 0.45 mg ml- 1 and for ethanolic extracts it was 0.15 mg ml- 1. The in vivo anthelmintic activity of aqueous and ethanolic extracts of I. hookeriana in sheep naturally infected with mixed species of gastrointestinal nematodes demonstrated a maximum (45.62%) egg count reduction in sheep treated with ethanolic extracts at 2 g kg- 1 body weight on day 10 after treatment, closely followed by ethanolic extracts at 1 g kg- 1 body weight on day 10 after treatment (43.54% egg count reduction). The aqueous extracts resulted in a maximum of 31.53% reduction in faecal egg counts on day 10 after treatment with 1 g kg- 1 body weight. Thus ethanolic extracts exhibited greater anthelmintic activity under both in vitro and in vivo conditions; this could be due to the presence of alcohol-soluble active ingredients in I. hookeriana. From the present study it can be suggested that I. hookeriana rhizome exhibited significant anthelmintic activity against gastrointestinal nematodes of sheep and has the potential to contribute to the control of gastrointestinal nematode parasites of small ruminants.

  3. Confocal microscopy of corneal stroma and endothelium after LASIK and PRK.

    PubMed

    Amoozadeh, Javad; Aliakbari, Soheil; Behesht-Nejad, Amir-Houshang; Seyedian, Mohammad-Amin; Rezvan, Bijan; Hashemi, Hassan

    2009-10-01

    To compare with confocal microscopy the changes in stromal keratocyte density and endothelial cell count due to photorefractive keratectomy (PRK) and LASIK. In this prospective study, 32 eyes (16 myopic patients) were examined with the NIDEK Confoscan 3 confocal microscope before and 6 months after PRK and LASIK. The preoperative mean myopia was -2.85+/-0.99 diopters (D) (range: -1.00 to -4.00 D) in 24 eyes that underwent PRK and -2.94+/-0.96 D (range: -2.00 to -4.25 D) in 8 eyes that underwent LASIK. Keratocyte density in the anterior and posterior stroma and the endothelial cell count were measured. Statistically significant changes were assessed using the t test. P<.05 was considered statistically significant. Preoperative hexagonal cell percentage in the LASIK group was 52.17+/-11.43 and 51.33+/-10.98 in the PRK group. Postoperatively, the percentages were 52.96+/-7.55 and 53.34+/-10.2, respectively. Six months postoperatively, keratocyte density changed by 367.12+/-103.35 cells/mm(2) (34.7% reduction) in the anterior stroma (P<.05) and 9.25+/-28.28 cells/mm(2) (1.31% reduction) in the posterior stroma (P>.05) for the LASIK group. In the PRK group, these values were 319.71+/-83.45 cells/mm(2) (31.13% reduction) in the anterior stroma (P<.05) and 0.17+/-38.97 cells/mm(2) (0.02% reduction) in the posterior stroma (P>.05). The changes in keratocyte densities were not statistically significant between groups (P>.05). The mean number of keratocytes decreased by 37.2% in the retroablation zone of the LASIK group (P<.05). No changes were noted in endothelial cell counts. A significant decrease occurred in the number of stromal keratocytes in the anterior stroma. Despite differences in surgery, the change in keratocyte density and endothelial cell counts were similar between LASIK and PRK groups (P>.05). Copyright 2009, SLACK Incorporated.

  4. Measurement of sound emitted by flying projectiles with aeroacoustic sources

    NASA Technical Reports Server (NTRS)

    Cho, Y. I.; Shakkottai, P.; Harstad, K. G.; Back, L. H.

    1988-01-01

    Training projectiles with axisymmetric ring cavities that produce intense tones in an airstream were shot in a straight-line trajectory. A ground-based microphone was used to obtain the angular distribution of sound intensity produced from the flying projectile. Data reduction required calculation of Doppler and attenuation factors. Also, the directional sensitivity of the ground-mounted microphone was measured and used in the data reduction. A rapid angular variation of sound intensity produced from the projectile was found that can be used to plot an intensity contour map on the ground. A full-scale field test confirmed the validity of the aeroacoustic concept of producing a relatively intense whistle from the projectile, and the usefulness of short-range flight tests that yield acoustic data free of uncertainties associated with diffraction, reflection, and refraction at jet boundaries in free-jet tests.

  5. Shot trajectory parameters in gold medal stationary shot-putters during world-class competition.

    PubMed

    Frossard, Laurent; Smeathers, James; O'Riordan, Alison; Goodman, Scott

    2007-10-01

    The parameters of the shot's trajectory were reported for male and female gold medalists (classes F52, F53, F54, and F55) who competed at the 2000 Paralympic Games and the 2002 International Paralympic Committee (IPC) World Championships. The specific objective was to determine the magnitude of differences in these parameters across classes and genders. The release velocity of the shot increased with the performance and the classification for both males (8.30 m/s - 9.96 m/s) and females (4.58 m/s - 8.50 m/s). The measured angle of the shot's trajectory at release also increased with the performance and the classification for both males (27.54 degrees - 32.47 degrees) and females (9.02 degrees - 34.52 degrees). The position of the shot from a fixed reference point at release revealed a similar trend for both males (2.01 m - 2.68 m) and females (1.16 m - 1.98 m), although it was weaker.

  6. Algorithm for Detection of Ground and Canopy Cover in Micropulse Photon-Counting Lidar Altimeter Data in Preparation for the ICESat-2 Mission

    NASA Technical Reports Server (NTRS)

    Herzfeld, Ute Christina; McDonald, Brian W.; Neumann, Thomas Allen; Wallin, Bruce F.; Neumann, Thomas A.; Markus, Thorsten; Brenner, Anita; Field, Christopher

    2014-01-01

    NASA's Ice, Cloud and Land Elevation Satellite-II (ICESat-2) mission is a decadal survey mission (2016 launch). The mission objectives are to measure land ice elevation, sea ice freeboard, and changes in these variables, as well as to collect measurements over vegetation to facilitate canopy height determination. Two innovative components will characterize the ICESat-2 lidar: 1) collection of elevation data by a multibeam system and 2) application of micropulse lidar (photon-counting) technology. A photon-counting altimeter yields clouds of discrete points, resulting from returns of individual photons, and hence new data analysis techniques are required for elevation determination and association of the returned points to reflectors of interest. The objective of this paper is to derive an algorithm that allows detection of ground under dense canopy and identification of ground and canopy levels in simulated ICESat-2 data, based on airborne observations with a Sigma Space micropulse lidar. The mathematical algorithm uses spatial statistical and discrete mathematical concepts, including radial basis functions, density measures, geometrical anisotropy, eigenvectors, and geostatistical classification parameters and hyperparameters. Validation shows that ground and canopy elevation, and hence canopy height, can be expected to be observable with high accuracy by ICESat-2 for all expected beam energies considered for instrument design (93.01%-99.57% correctly selected points for a beam with expected return of 0.93 mean signals per shot (msp), and 72.85%-98.68% for 0.48 msp). The algorithm derived here is generally applicable for elevation determination from photoncounting lidar altimeter data collected over forested areas, land ice, sea ice, and land surfaces, as well as for cloud detection.

  7. The Source Physics Experiments (SPE) at the Nevada National Security Site (NNSS): An Overview

    NASA Astrophysics Data System (ADS)

    Snelson, C. M.; Chipman, V.; White, R. L.; Emmitt, R.; Townsend, M.; Barker, D.; Lee, P.

    2012-12-01

    Understanding the changes in seismic energy as it travels from the near field to the far field is the ultimate goal in monitoring for explosive events of interest. This requires a clear understanding of explosion phenomenology as it relates to seismic, infrasound, and acoustic signals. Although there has been much progress in modeling these phenomena, this has been primarily based in the empirical realm. As a result, the logical next step in advancing the seismic monitoring capability of the United States is to conduct field tests that can expand the predictive capability of the physics-based modeling currently under development. The Source Physics Experiment at the Nevada National Security Site (SPE) is the first step in this endeavor to link the empirically based with the physics-based modeling. This is a collaborative project between National Security Technologies (NSTec), Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Sandia National Laboratories (SNL), the Defense Threat Reduction Agency (DTRA), and the Air Force Technical Applications Center (AFTAC). The test series require both the simple and complex cases to fully characterize the problem, which is to understand the transition of seismic energy from the near field to the far field; to understand the development of S-waves in explosives sources; and how anisotropy controls seismic energy transmission and partitioning. The current series is being conducted in a granite body called the Climax Stock. This location was chosen for several reasons, including the fairly homogenous granite; the location of previous nuclear tests in the same rock body; and generally the geology has been well characterized. The simple geology series is planned for 7 shots using conventional explosives in the same shot hole surrounded by Continuous Reflectometry for Radius vs. Time Experiment (CORRTEX), Time of Arrival (TOA), Velocity of Detonation (VOD), down-hole accelerometers, surface accelerometers, infrasound, and a suite of seismic sensors of various frequency bands from the near field to the far field. This allows for the use of a single test bed in the simple geology case instead of multiple tests beds to obtain the same results. The shots are planned at various depths to obtain a Green's function, scaled-depth of burial data, nominal depth of burial data and damage zone data. SPE1 was conducted in May 2011 as a 220 lb (100 kg) TNT equivalent calibration shot at a depth of 180 ft (55 m). SPE2 was conducted in October 2011 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m). SPE3 was conducted in July 2012 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m) in the damaged zone. Over 400 data channels were recorded for each of these shots and data recovery was about 95% with high signal to noise ratio. Once the simple geology site data has been utilized, a new test bed will be developed in a complex geology site to test these physics based models. Ultimately, the results from this project will provide the next advances in the science of monitoring to enable a physics-based predicative capability. This work was done by National Security Technologies, LLC, under Contract No. DE-AC52-06NA25946 with the U.S. Department of Energy. DOE/NV/25946--1584

  8. Judgement bias in predicting the success of one's own basketball free throws but not those of others.

    PubMed

    Cañal-Bruland, Rouwen; Balch, Lars; Niesert, Loet

    2015-07-01

    Skilled basketball players are supposed to hit more often from the free throw distance than would be predicted by their shooting performances at adjacent distances. This is dubbed an especial skill. In the current study, we examined whether especial skills in free throw performance in basketball map onto especial skills in visually judging the success of basketball free throws. In addition, we tested whether this effect would be present in those who predict their own shots but absent in those who judge shots performed by another person. Eight skilled basketball players were coupled with eight equally skilled players, and performed 150 set shots from five different distances (including the free throw distance) while the yoked partner observed the shots. At the moment of ball release, the performers' and the observers' vision were synchronously occluded using liquid-crystal occlusion goggles, and both independently judged whether the shot was successful or not. Results did not replicate an especial skill effect in shooting performance. Based on signal detection theory (SDT) measures (d' and criterion c), results also revealed no especial skill for visually discriminating successful from unsuccessful shots at the foul line when compared to other distances. However, players showed an especial skill judgement bias towards judging balls 'in' at the foul line, but not at other distances. Importantly, this bias was only present in those who judged the success of their own shots, but not in those who judged the shots performed by someone else.

  9. Lead exposure in Canada geese of the Eastern Prairie Population

    USGS Publications Warehouse

    DeStefano, S.; Brand, C.J.; Rusch, D.H.; Finley, Daniel L.; Gillespie, M.M.

    1991-01-01

    We monitored lead exposure in Eastern Prairie Population Canada geese during summer-winter, 1986-1987 and 1987-1988 at 5 areas. Blood lead concentrations in geese trapped during summer at Cape Churchill Manitoba were below levels indicative of recent lead exposure (0.18 ppm). Geese exposed to lead (≥0.18 ppm blood lead) increased to 7.6% at Oak Hammock Wildlife Management Area (WMA), southern Manitoba, where lead shot was still in use, and to 10.0% at Roseau River WMA, northern Minnesota, when fall-staging geese were close to a source of lead shot in Manitoba. Proportion of birds exposed to lead dropped to <2% at Lac Qui Parle WMA, Minnesota, a steel shot zone since 1980. On the wintering grounds at Swan Lake National Wildlife Refuge in Missouri, 4.9% of all geese showed exposure to lead before the hunting season. Lead exposure rose to 10.0% after hunting ended and then decreased to 5.2% in late winter. Incidence of lead shot in gizzards and concentrations of lead in livers supported blood assay data. Soil samples indicated that lead shot continues to be available to geese at Swan Lake, even though the area was established as a non-toxic shot zone in 1978. Steel shot zones have reduced lead exposure in the Eastern Prairie Population, but lead shot persists in the environment and continues to account for lead exposure and mortality in Eastern Prairie Population Canada geese.

  10. Subjective State, Blood Pressure, and Behavioral Control Changes Produced by an "Energy Shot"

    PubMed

    Marczinski, Cecile A; Stamates, Amy L; Ossege, Julianne; Maloney, Sarah F; Bardgett, Mark E; Brown, Clifford J

    2014-06-01

    Background: Energy drinks and energy shots are popular consumer beverages that are advertised to increase feelings of alertness. Typically, these products include high levels of caffeine, a mild psychostimulant drug. The scientific evidence demonstrating the specific benefits of energy products to users in terms of subjective state and objective performance is surprisingly lacking. Moreover, there are rising health concerns associated with the use of these products. Therefore, the purpose of this study was to investigate the acute effects of a popular energy shot (5-Hour Energy ® ) on subjective and objective measures that were assessed hourly for 6 hours following consumption. Methods: Participants ( n =14) completed a three-session study where they received the energy shot, a placebo control, and no drink. Following dose administration, participants completed subjective Profile of Mood States ratings hourly for 6 hours. Participants also repeatedly completed a behavioral control task (the cued go/no-go task) and provided blood pressure and pulse rate readings at each hour. Results: Consumption of the energy shot did improve subjective state, as measured by increased ratings of vigor and decreased ratings of fatigue. However, the energy shot did not alter objective performance, which worsened over time. Importantly, the energy shot elevated both systolic and diastolic blood pressure. Conclusions: Consumption of one energy shot may only result in modest benefits to subjective state. Individuals with preexisting hypertension or other medical conditions should be cautious about using these new consumer products.

  11. Microbiological Load of Edible Insects Found in Belgium.

    PubMed

    Caparros Megido, Rudy; Desmedt, Sandrine; Blecker, Christophe; Béra, François; Haubruge, Éric; Alabi, Taofic; Francis, Frédéric

    2017-01-13

    Edible insects are gaining more and more attention as a sustainable source of animal protein for food and feed in the future. In Belgium, some insect products can be found on the market, and consumers are sourcing fresh insects from fishing stores or towards traditional markets to find exotic insects that are illegal and not sanitarily controlled. From this perspective, this study aims to characterize the microbial load of edible insects found in Belgium (i.e., fresh mealworms and house crickets from European farms and smoked termites and caterpillars from a traditional Congolese market) and to evaluate the efficiency of different processing methods (blanching for all species and freeze-drying and sterilization for European species) in reducing microorganism counts. All untreated insect samples had a total aerobic count higher than the limit for fresh minced meat (6.7 log cfu/g). Nevertheless, a species-dependent blanching step has led to a reduction of the total aerobic count under this limit, except for one caterpillar species. Freeze-drying and sterilization treatments on European species were also effective in reducing the total aerobic count. Yeast and mold counts for untreated insects were above the Good Manufacturing Practice limits for raw meat, but all treatments attained a reduction of these microorganisms under this limit. These results confirmed that fresh insects, but also smoked insects from non-European trades, need a cooking step (at least composed of a first blanching step) before consumption. Therefore, blanching timing for each studied insect species is proposed and discussed.

  12. Lymphocyte count as a sign of immunoparalysis and its correlation with nutritional status in pediatric intensive care patients with sepsis: A pilot study.

    PubMed

    Manzoli, Talita Freitas; Delgado, Artur Figueiredo; Troster, Eduardo Juan; de Carvalho, Werther Brunow; Antunes, Ana Caroline Barreto; Marques, Desirée Mayara; Zamberlan, Patrícia

    2016-11-01

    Developing malnutrition during hospitalization is well recognized worldwide, and children are at a relatively higher risk for malnutrition than adults. Malnutrition can lead to immune dysfunction, which is associated with a higher mortality rate due to sepsis, the most frequent cause of death in pediatric intensive care units (PICUs). The aim of this study was to investigate whether malnourished patients are more likely to have relative or absolute lymphopenia and, consequently, worse prognoses. We enrolled 14 consecutive patients with sepsis whose legal representatives provided written informed consent. Patients were classified as normal or malnourished based on anthropometric measurements. As an additional evaluation of nutritional status, serum albumin and zinc were measured on the 1st and 7th days of hospitalization. Lymphocyte count was also measured on the 1st and 7th days. Clinicaltrials.gov: NCT02698683. Malnutrition prevalence rates were 33.3% and 42.8% based on weight and height, respectively. Laboratory analyses revealed a reduction of serum albumin in 100% of patients and reduction of zinc in 93.3% of patients. A total of 35% of patients had fewer than 500 lymphocytes/mm3 on their first day in the PICU. Lymphocyte counts and zinc concentrations significantly increased during hospitalization. Nutritional evaluations, including anthropometric measurements, were not correlated with lymphocyte counts. Lymphocyte counts concomitantly increased with zinc levels, suggesting that micronutrient supplementation benefits patients with sepsis.

  13. Lymphocyte count as a sign of immunoparalysis and its correlation with nutritional status in pediatric intensive care patients with sepsis: A pilot study

    PubMed Central

    Manzoli, Talita Freitas; Delgado, Artur Figueiredo; Troster, Eduardo Juan; de Carvalho, Werther Brunow; Antunes, Ana Caroline Barreto; Marques, Desirée Mayara; Zamberlan, Patrícia

    2016-01-01

    OBJECTIVES: Developing malnutrition during hospitalization is well recognized worldwide, and children are at a relatively higher risk for malnutrition than adults. Malnutrition can lead to immune dysfunction, which is associated with a higher mortality rate due to sepsis, the most frequent cause of death in pediatric intensive care units (PICUs). The aim of this study was to investigate whether malnourished patients are more likely to have relative or absolute lymphopenia and, consequently, worse prognoses. METHODS: We enrolled 14 consecutive patients with sepsis whose legal representatives provided written informed consent. Patients were classified as normal or malnourished based on anthropometric measurements. As an additional evaluation of nutritional status, serum albumin and zinc were measured on the 1st and 7th days of hospitalization. Lymphocyte count was also measured on the 1st and 7th days. Clinicaltrials.gov: NCT02698683. RESULTS: Malnutrition prevalence rates were 33.3% and 42.8% based on weight and height, respectively. Laboratory analyses revealed a reduction of serum albumin in 100% of patients and reduction of zinc in 93.3% of patients. A total of 35% of patients had fewer than 500 lymphocytes/mm3 on their first day in the PICU. Lymphocyte counts and zinc concentrations significantly increased during hospitalization. CONCLUSIONS: Nutritional evaluations, including anthropometric measurements, were not correlated with lymphocyte counts. Lymphocyte counts concomitantly increased with zinc levels, suggesting that micronutrient supplementation benefits patients with sepsis. PMID:27982165

  14. Mumps and the Vaccine (Shot) to Prevent It

    MedlinePlus

    ... 6 months to 11 months old should have 1 dose of MMR shot before traveling abroad. Fact Sheet for Parents Color [ ... my child? To learn more about the MMR shot, talk to your child’s doctor, call 1-800-CDC-INFO, or visit www.cdc.gov/ ...

  15. Calibration Shots Recorded for the Salton Seismic Imaging Project, Salton Trough, California

    NASA Astrophysics Data System (ADS)

    Murphy, J. M.; Rymer, M. J.; Fuis, G. S.; Stock, J. M.; Goldman, M.; Sickler, R. R.; Miller, S. A.; Criley, C. J.; Ricketts, J. W.; Hole, J. A.

    2009-12-01

    The Salton Seismic Imaging Project (SSIP) is a collaborative venture between the U.S. Geological Survey, California Institute of Technology, and Virginia Polytechnic Institute and State University, to acquire seismic reflection/wide angle refraction data, and currently is scheduled for data acquisition in 2010. The purpose of the project is to get a detailed subsurface 3-D image of the structure of the Salton Trough (including both the Coachella and Imperial Valleys) that can be used for earthquake hazards analysis, geothermal studies, and studies of the transition from ocean-ocean to continent-continent plate-boundary. In June 2009, a series of calibration shots were detonated in the southern Imperial Valley with specific goals in mind. First, these shots were used to measure peak particle velocity and acceleration at various distances from the shots. Second, the shots were used to calibrate the propagation of energy through sediments of the Imperial Valley. Third, the shots were used to test the effects of seismic energy on buried clay drainage pipes, which are abundant throughout the irrigated parts of the Salton Trough. Fourth, we tested the ODEX drilling technique, which uses a down-hole casing hammer for a tight casing fit. Information obtained from the calibration shots will be used for final planning of the main project. The shots were located in an unused field adjacent to Hwy 7, about 6 km north of the U.S. /Mexican border (about 18 km southeast of El Centro). Three closely spaced shot points (16 meters apart) were aligned N-S and drilled to 21-m, 23.5-m, and 27-m depth. The holes were filled with 23-kg, 68-kg, and 123-kg of ammonium-nitrate explosive, respectively. Four instrument types were used to record the seismic energy - six RefTek RT130 6-channel recorders with a 3-component accelerometer and a 3-component 2-Hz velocity sensor, seven RefTek RT130 3-channel recorders with a 3-component 4.5-Hz velocity sensor, 35 Texans with a vertical component 4.5-Hz velocity sensor, and a 60-channel cabled array with 40-Hz sensors. Irrigation districts in both the Coachella Valley and Imperial Valley use clay drainage pipes buried beneath fields to remove irrigation water and prevent ponding. To determine the effect of seismic energy on the drain pipes, we exposed sections of pipe several meters long with a backhoe at distances of 7-15 meters from the shot holes, and, after each shot, visually inspected the pipes. Our shots produced no pipe damage.

  16. Flu shots and the characteristics of unvaccinated elderly Medicare beneficiaries.

    PubMed

    Lochner, Kimberly A; Wynne, Marc

    2011-12-21

    Data from the Medicare Current Beneficiary Survey, 2009. • Overall, 73% of Medicare beneficiaries aged 65 years and older reported receiving a flu shot for the 2008 flu season, but vaccination rates varied by socio-demographic characteristics. Flu vaccination was lowest for beneficiaries aged 65-74 years old, who were non-Hispanic Blacks and Hispanics, were not married, had less than a high school education, or who were eligible for Medicaid (i.e., dual eligibles). • Healthcare utilization and personal health behavior were also related to vaccination rates, with current smokers and those with no hospitalizations or physician visits being less likely to be vaccinated. • Among those beneficiaries who reported receiving a flu shot, 59% received it in a physician's office or clinic, with the next most common setting being in the community (21%); e.g., grocery store, shopping mall, library, or church. • Among those beneficiaries who did not receive a flu shot, the most common reasons were beliefs that the shot could cause side effects or disease (20%), that they didn't think the shot could prevent the flu (17%), or that the shot wasn't needed (16%). Less than 1% reported that they didn't get the flu shot because of cost. Elderly persons (aged 65 years and older) are at increased risk of complications from influenza, with the majority of influenza-related hospitalizations and deaths occurring among the elderly (Fiore et al., 2010). Most physicians recommend their elderly patients get a flu shot each year, and many hospitals inquire about elderly patient's immunization status upon admission, providing a vaccination if requested. The importance of getting a flu shot is underscored by the Department of Health and Human Services' Healthy People initiative, which has set a vaccination goal of 90% for the Nation's elderly by the year 2020 (Department of Health and Human Services [DHHS], 2011). Although all costs related to flu shots are covered by Medicare, requiring no co-pay on the part of the beneficiary (Centers for Medicare and Medicaid Services, 2011), for the 2008 flu season, only 73% of non-institutionalized Medicare beneficiaries, aged 65 years and older, reported receiving one. This report presents the most recent data on flu vaccination rates among non-institutionalized elderly Medicare beneficiaries and their association with socio-demographic and personal health characteristics. The report also describes the places beneficiaries received their flu shot and, for those not getting vaccinated, the reasons reported for not doing so. Public Domain.

  17. Bipolar radiofrequency ablation of benign thyroid nodules using a multiple overlapping shot technique in a 3-month follow-up.

    PubMed

    Kohlhase, Konstantin David; Korkusuz, Yücel; Gröner, Daniel; Erbelding, Christian; Happel, Christian; Luboldt, Wolfgang; Grünwald, Frank

    2016-08-01

    Purpose The aim of this study was to evaluate the decrease of benign thyroid nodules after bipolar radiofrequency ablation (RFA) in a 3-month follow-up using a multiple overlapping shot technique ('MOST'). Methods A total of 18 patients with 20 symptomatic benign thyroid nodules (17 cold nodules, 3 hyperfunctioning nodules) were treated in one single session by bipolar RFA. Bipolar ablation was performed using MOST. The nodule volumes were measured prior to ablation and 3 months after the procedure using ultrasound. The population consisted of either solid (>80% solid tissue within the volume of interest), complex, or cystic nodules (<20% solid tissue within the volume of interest). Results Bipolar RFA resulted in a highly significant (p < 0.0001) decrease of nodule volume (ΔV), median 5.3 mL (range 0.13-43.1 mL), corresponding to a relative reduction in mean of 56 ± 17.9%. Median initial volume was 8 mL (range 0.48-62 mL); 3 months after ablation a median volume of 2.3 mL (range 0.3-32 mL) was measured. Nodule growth ≥50% occurred in 70% (14 nodules). At the follow-up no complications such as infections, persisting pain, nerve injuries or immunogen stimulation occurred. Patients with cold nodules (15) remained euthyroid, with hyperfunctioning nodules either euthyroid (2) or latent hypofunctional (1). Conclusion The use of bipolar RFA is an effective, safe and suitable thermoablative technique to treat benign thyroid nodules. Combined with the multiple overlapping shot technique it allows sufficient ablation.

  18. Effect of resonant magnetic perturbations on three dimensional equilibria in the Madison Symmetric Torus reversed-field pinch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Munaretto, S., E-mail: smunaretto@wisc.edu; Chapman, B. E.; Nornberg, M. D.

    2016-05-15

    The orientation of 3D equilibria in the Madison Symmetric Torus (MST) [R. N. Dexter et al., Fusion Technol. 19, 131 (1991)] reversed-field pinch can now be controlled with a resonant magnetic perturbation (RMP). Absent the RMP, the orientation of the stationary 3D equilibrium varies from shot to shot in a semi-random manner, making its diagnosis difficult. Produced with a poloidal array of saddle coils at the vertical insulated cut in MST's thick conducting shell, an m = 1 RMP with an amplitude b{sub r}/B ∼ 10% forces the 3D structure into any desired orientation relative to MST's diagnostics. This control has led to improvedmore » diagnosis, revealing enhancements in both the central electron temperature and density. With sufficient amplitude, the RMP also inhibits the generation of high-energy (>20 keV) electrons, which otherwise emerge due to a reduction in magnetic stochasticity in the core. Field line tracing reveals that the RMP reintroduces stochasticity to the core. A m = 3 RMP of similar amplitude has little effect on the magnetic topology or the high-energy electrons.« less

  19. Coherent anti-Stokes Raman scattering and spontaneous Raman scattering diagnostics of nonequilibrium plasmas and flows

    NASA Astrophysics Data System (ADS)

    Lempert, Walter R.; Adamovich, Igor V.

    2014-10-01

    The paper provides an overview of the use of coherent anti-Stokes Raman scattering (CARS) and spontaneous Raman scattering for diagnostics of low-temperature nonequilibrium plasmas and nonequilibrium high-enthalpy flows. A brief review of the theoretical background of CARS, four-wave mixing and Raman scattering, as well as a discussion of experimental techniques and data reduction, are included. The experimental results reviewed include measurements of vibrational level populations, rotational/translational temperature, electric fields in a quasi-steady-state and transient molecular plasmas and afterglow, in nonequilibrium expansion flows, and behind strong shock waves. Insight into the kinetics of vibrational energy transfer, energy thermalization mechanisms and dynamics of the pulse discharge development, provided by these experiments, is discussed. Availability of short pulse duration, high peak power lasers, as well as broadband dye lasers, makes possible the use of these diagnostics at relatively low pressures, potentially with a sub-nanosecond time resolution, as well as obtaining single laser shot, high signal-to-noise spectra at higher pressures. Possibilities for the development of single-shot 2D CARS imaging and spectroscopy, using picosecond and femtosecond lasers, as well as novel phase matching and detection techniques, are discussed.

  20. Centroid stabilization in alignment of FOA corner cube: designing of a matched filter

    NASA Astrophysics Data System (ADS)

    Awwal, Abdul; Wilhelmsen, Karl; Roberts, Randy; Leach, Richard; Miller Kamm, Victoria; Ngo, Tony; Lowe-Webb, Roger

    2015-02-01

    The current automation of image-based alignment of NIF high energy laser beams is providing the capability of executing multiple target shots per day. An important aspect of performing multiple shots in a day is to reduce additional time spent aligning specific beams due to perturbations in those beam images. One such alignment is beam centration through the second and third harmonic generating crystals in the final optics assembly (FOA), which employs two retro-reflecting corner cubes to represent the beam center. The FOA houses the frequency conversion crystals for third harmonic generation as the beams enters the target chamber. Beam-to-beam variations and systematic beam changes over time in the FOA corner-cube images can lead to a reduction in accuracy as well as increased convergence durations for the template based centroid detector. This work presents a systematic approach of maintaining FOA corner cube centroid templates so that stable position estimation is applied thereby leading to fast convergence of alignment control loops. In the matched filtering approach, a template is designed based on most recent images taken in the last 60 days. The results show that new filter reduces the divergence of the position estimation of FOA images.

  1. One- and two-mode squeezed light in correlated interferometry

    NASA Astrophysics Data System (ADS)

    Ruo-Berchera, I.; Degiovanni, I. P.; Olivares, S.; Samantaray, N.; Traina, P.; Genovese, M.

    2015-11-01

    We study in detail a system of two interferometers aimed at detecting extremely faint phase fluctuations. This system can represent a breakthrough for detecting a faint correlated signal that would remain otherwise undetectable even using the most sensitive individual interferometric devices, as in the case of so-called holographic noise. The signature of this kind of noise emerges as a correlation between the output signals of the interferometers. On the other hand, when holographic noise is absent one expects uncorrelated signals since the time-averaged fluctuations due to shot noise and other independent contributions vanish (though limiting the overall sensitivity). We show how injecting quantum light in the free ports of the interferometers can reduce the photon noise of the system beyond the shot noise, enhancing the resolution in the phase-correlation estimation. We analyze the use of both the two-mode squeezed vacuum and two independent squeezed states. Our results confirm the benefit of using squeezed beams together with strong coherent beams in interferometry. We also investigate the possible use of the two-mode squeezed vacuum, discovering interesting and unexplored areas of application of bipartite entanglement, in particular the possibility of reaching in principle a surprising uncertainty reduction.

  2. Efficacy of silver diamine fluoride as an antibacterial as well as antiplaque agent compared to fluoride varnish and acidulated phosphate fluoride gel: an in vivo study.

    PubMed

    Shah, Shalin; Bhaskar, Vijay; Venkataraghavan, Karthik; Choudhary, Prashant; Ganesh, M; Trivedi, Krishna

    2013-01-01

    Silver diamine fluoride (SDF) is already proven as an antibacterial agent in vitro. Present study was formulated to compare the efficacy of SDF as an antibacterial as well as antiplaque agent in vivo with fluoride varnish and acidulated phosphate fluoride (APF) gel. Total 123 children (male = 82, female = 41) were included in the study for a period of 18 months. Children were divided into three different groups-Group 1: SDF; Group 2: fluoride varnish; and Group 3: APF gel. All subjects were evaluated via plaque score at 6 th, 12 th, and 18 th months as well as Streptococcus mutans counts in saliva at 72 h, 6 th, 12 th, and 18 th months of follow-up. Significant reduction was found in plaque score as well as S. mutans counts irrespective of group division. On intergroup comparison, no statistically significant difference was found in plaque score, but significant reduction in S. mutans counts was found in Group 1 as compared with Groups 2 and 3, while no significant difference was found between Groups 2 and 3. In vivo application of SDF on enamel significantly decreases S. mutans counts as compared to fluoride varnish and APF gel.

  3. The evolution of vertebral formulae in Hominoidea.

    PubMed

    Thompson, Nathan E; Almécija, Sergio

    2017-09-01

    Primate vertebral formulae have long been investigated because of their link to locomotor behavior and overall body plan. Knowledge of the ancestral vertebral formulae in the hominoid tree of life is necessary to interpret the pattern of evolution among apes, and to critically evaluate the morphological adaptations involved in the transition to hominin bipedalism. Though many evolutionary hypotheses have been proposed based on living and fossil species, the application of quantitative phylogenetic methods for thoroughly reconstructing ancestral vertebral formulae and formally testing patterns of vertebral evolution is lacking. To estimate the most probable scenarios of hominoid vertebral evolution, we utilized an iterative ancestral state reconstruction approach to determine likely ancestral vertebral counts in apes, humans, and other anthropoid out-groups. All available ape and hominin fossil taxa with an inferred regional vertebral count were included in the analysis. Sensitivity iterations were performed both by changing the phylogenetic position of fossil taxa with a contentious placement, and by changing the inferred number of vertebrae in taxa with uncertain morphology. Our ancestral state reconstruction results generally support a short-backed hypothesis of human evolution, with a Pan-Homo last common ancestor possessing a vertebral formulae of 7:13:4:6 (cervical:thoracic:lumbar:sacral). Our results indicate that an initial reduction in lumbar vertebral count and increase in sacral count is a synapomorphy of crown hominoids (supporting an intermediate-backed hypothesis for the origins of the great ape-human clade). Further reduction in lumbar count occurs independently in orangutans and African apes. Our results highlight the complexity and homoplastic nature of vertebral count evolution, and give little support to the long-backed hypothesis of human evolution. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. SunShot Initiative Portfolio Book 2014

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solar Energy Technologies Office

    2014-05-01

    The 2014 SunShot Initiative Portfolio Book outlines the progress towards the goals outlined in the SunShot Vision Study. Contents include overviews of each of SunShot’s five subprogram areas, as well as a description of every active project in the SunShot’s project portfolio as of May 2014.

  5. 32 CFR 632.5 - Use of firearms.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... not fire if shots are likely to harm innocent bystanders. (3) Since warning shots could harm innocent bystanders, avoid firing them. However, when lesser degrees of force have failed, the law enforcement or.... If able to avoid hazards to innocent persons in these cases, fire warning shots. (4) Aim to disable...

  6. Tdap (tetanus, diphtheria and pertussis) vaccine - what you need to know

    MedlinePlus

    ... in 3 adults) Redness or swelling where the shot was given (about 1 person in 5) Mild fever of at least ... Pain where the shot was given (up to 1 in 5 or 6) Redness or swelling where the shot was given (up to about 1 in 16 ...

  7. 32 CFR 552.100 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... designed or redesigned, made or remade, modified or remodified to automatically fire more than one shot by..., incendiary, blank, shotgun, black powder, and shot). Items shall only be considered as ammunition when loaded... smooth bore either a number of ball shot or a single projectile for each single pull of the trigger. (j...

  8. 32 CFR 552.100 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... designed or redesigned, made or remade, modified or remodified to automatically fire more than one shot by..., incendiary, blank, shotgun, black powder, and shot). Items shall only be considered as ammunition when loaded... smooth bore either a number of ball shot or a single projectile for each single pull of the trigger. (j...

  9. 16 CFR 1500.17 - Banned hazardous substances.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) Voluntary standard. (1) One alternative to the tip-angle requirement that the Commission considered is to... Multiple Shot requires that large multiple-tube devices not tip over (except as the result of the last shot) when shot on a 2-inch thick medium-density foam pad. The Commission cannot conclude that AFSL's...

  10. 32 CFR 552.100 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... designed or redesigned, made or remade, modified or remodified to automatically fire more than one shot by..., incendiary, blank, shotgun, black powder, and shot). Items shall only be considered as ammunition when loaded... smooth bore either a number of ball shot or a single projectile for each single pull of the trigger. (j...

  11. 32 CFR 552.100 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... designed or redesigned, made or remade, modified or remodified to automatically fire more than one shot by..., incendiary, blank, shotgun, black powder, and shot). Items shall only be considered as ammunition when loaded... smooth bore either a number of ball shot or a single projectile for each single pull of the trigger. (j...

  12. Vaccines for Your Children: Protect Your Child at Every Age

    MedlinePlus

    ... shots. 1 to 2 Months Learn about the 1-2 months shots and the importance of staying on schedule. 4 ... 18 Years Learn about the 13-18 year shots, vaccines needed for travel, and vaccines before ... Pregnancy Birth 1 to 2 months 4 months 6 months 7 ...

  13. 16 CFR 1500.17 - Banned hazardous substances.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) Voluntary standard. (1) One alternative to the tip-angle requirement that the Commission considered is to... Multiple Shot requires that large multiple-tube devices not tip over (except as the result of the last shot) when shot on a 2-inch thick medium-density foam pad. The Commission cannot conclude that AFSL's...

  14. Flu Facts

    MedlinePlus

    ... Your doctor will probably recommend that you get one. Flu vaccines are available as a shot. The shot contains killed flu viruses and will ... CDC). This nasal mist did not help prevent cases of flu between 2013 and ... don't have reactions to a flu shot, although a few may notice a fever, sore ...

  15. Optical Physics Study of Laser Interactions with Solids for Ultra-Trace Materials Analysis Using RIS. Phase 1.

    DTIC Science & Technology

    1987-04-24

    eliminated. Averaging the mass spectra from only 500 laser shots (50 seconds with this system) resulted in a detection limit of r15 ppb. The...resolution. Fluctuations in laser pulse energy from shot to shot appear as noise in the interleaved data, but averaging of several such traces gives a good...ranging from 0to 120 ix Wm- 2. quantity of material volatilized was proportional to the number of lase shots . A simple time-of-flight mass spectrometer was

  16. Statistical properties of radiation power levels from a high-gain free-electron laser at and beyond saturation

    NASA Astrophysics Data System (ADS)

    Schroeder, C. B.; Fawley, W. M.; Esarey, E.

    2003-07-01

    We investigate the statistical properties (e.g., shot-to-shot power fluctuations) of the radiation from a high-gain free-electron laser (FEL) operating in the nonlinear regime. We consider the case of an FEL amplifier reaching saturation whose shot-to-shot fluctuations in input radiation power follow a gamma distribution. We analyze the corresponding output power fluctuations at and beyond saturation, including beam energy spread effects, and find that there are well-characterized values of undulator length for which the fluctuations reach a minimum.

  17. Effects of Laser and Shot Peening on Fatigue Crack Growth in Friction Stir Welds

    NASA Technical Reports Server (NTRS)

    Hatamleh, Omar; Forman, Royce; Lyons, Jed

    2006-01-01

    The effects of laser, and shot peening on the fatigue life of Friction Stir Welds (FSW) have been investigated. The surface roughness resulting from various peening techniques was assessed, and the fracture surfaces microstructure was characterized. Laser peening resulted in an increase in fatigue life approximately 60%, while shot peening resulted in 10% increase when compared to the unpeened material. The surface roughness of shot peening was significantly higher compared to the base material, while specimens processed with laser peening were relatively smooth.

  18. Equation of State for RX-08-EL and RX-08-EP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, E.L.; Walton, J.

    1985-05-07

    JWL Equations of State (EOS's) have been estimated for RX-08-EL and RX-08-EP. The estimated JWL EOS parameters are listed. Previously, we derived a JWL EOS for RX-08-EN based on DYNA2D hydrodynamic code cylinder computations and comparisons with experimental cylinder test results are shown. The experimental cylinder shot results for RX-08-EL, shot K-473, were compared to the experimental cylinder shot results for RX-08-EN, shot K-463, as a reference. 10 figs., 6 tabs.

  19. Comparative toxicity of lead shot in black ducks (Anas rubripes) and mallards (Anas platyrhynchos)

    USGS Publications Warehouse

    Rattner, B.A.; Fleming, W.J.; Bunck, C.M.

    1989-01-01

    In winter, pen-reared and wild black ducks (Anas rubripes), and game farm and wild mallards (Anas platyrhynchos), maintained on pelleted feed, were sham-dosed or given one number 4 lead shot. After 14 days, dosed birds were redosed with two or four additional lead shot. This dosing regimen also was repeated in summer using pen-reared black ducks and game farm mallards. Based upon mortality, overt intoxication, weight change, delta-aminolevulinic acid dehydratase activity and protoporphyrin concentration, black ducks and mallards were found to be equally tolerant to lead shot. However, captive wild ducks were more sensitive than their domesticated counterparts, as evidenced by greater mortality and weight loss following lead shot administration. This difference may be related to stress associated with captivity and unnatural diet.

  20. Attention and the evolution of Hollywood film.

    PubMed

    Cutting, James E; DeLong, Jordan E; Nothelfer, Christine E

    2010-03-01

    Reaction times exhibit a spectral patterning known as 1/f, and these patterns can be thought of as reflecting time-varying changes in attention. We investigated the shot structure of Hollywood films to determine if these same patterns are found. We parsed 150 films with release dates from 1935 to 2005 into their sequences of shots and then analyzed the pattern of shot lengths in each film. Autoregressive and power analyses showed that, across that span of 70 years, shots became increasingly more correlated in length with their neighbors and created power spectra approaching 1/f. We suggest, as have others, that 1/f patterns reflect world structure and mental process. Moreover, a 1/f temporal shot structure may help harness observers' attention to the narrative of a film.

  1. High-dynamic-range cross-correlator for shot-to-shot measurement of temporal contrast

    NASA Astrophysics Data System (ADS)

    Kon, Akira; Nishiuchi, Mamiko; Kiriyama, Hiromitsu; Ogura, Koichi; Mori, Michiaki; Sakaki, Hironao; Kando, Masaki; Kondo, Kiminori

    2017-01-01

    The temporal contrast of an ultrahigh-intensity laser is a crucial parameter for laser plasma experiments. We have developed a multichannel cross-correlator (MCCC) for single-shot measurements of the temporal contrast in a high-power laser system. The MCCC is based on third-order cross-correlation, and has four channels and independent optical delay lines. We have experimentally demonstrated that the MCCC system achieves a high dynamic range of ˜1012 and a large temporal window of ˜1 ns. Moreover, we were able to measure the shot-to-shot fluctuations of a short-prepulse intensity at -26 ps and long-pulse (amplified spontaneous emission, ASE) intensities at -30, -450, and -950 ps before the arrival of the main pulse at the interaction point.

  2. Automatic video shot boundary detection using k-means clustering and improved adaptive dual threshold comparison

    NASA Astrophysics Data System (ADS)

    Sa, Qila; Wang, Zhihui

    2018-03-01

    At present, content-based video retrieval (CBVR) is the most mainstream video retrieval method, using the video features of its own to perform automatic identification and retrieval. This method involves a key technology, i.e. shot segmentation. In this paper, the method of automatic video shot boundary detection with K-means clustering and improved adaptive dual threshold comparison is proposed. First, extract the visual features of every frame and divide them into two categories using K-means clustering algorithm, namely, one with significant change and one with no significant change. Then, as to the classification results, utilize the improved adaptive dual threshold comparison method to determine the abrupt as well as gradual shot boundaries.Finally, achieve automatic video shot boundary detection system.

  3. High current nonlinear transmission line based electron beam driver

    NASA Astrophysics Data System (ADS)

    Hoff, B. W.; French, D. M.; Simon, D. S.; Lepell, P. D.; Montoya, T.; Heidger, S. L.

    2017-10-01

    A gigawatt-class nonlinear transmission line based electron beam driver is experimentally demonstrated. Four experimental series, each with a different Marx bank charge voltage (15, 20, 25, and 30 kV), were completed. Within each experimental series, shots at peak frequencies ranging from 950 MHz to 1.45 GHz were performed. Peak amplitude modulations of the NLTL output voltage signal were found to range between 18% and 35% for the lowest frequency shots and between 5% and 20% for the highest frequency shots (higher modulation at higher Marx charge voltage). Peak amplitude modulations of the electron beam current were found to range between 10% and 20% for the lowest frequency shots and between 2% and 7% for the highest frequency shots (higher modulation at higher Marx charge voltage).

  4. If it looks like a duck and quacks like a duck…: Energy "shots" should be regulated as energy drinks in Canada.

    PubMed

    Hammond, David; Reid, Jessica L

    2016-06-27

    In 2012, Health Canada transitioned caffeinated energy drinks from Natural Health Product to Food and Drug classification and regulations, implementing temporary guidelines with requirements such as caffeine content limits, mandatory cautionary labelling, and restrictions on health claims. "Energy shots" often contain as much or more caffeine compared to energy drinks and have been associated with a similar number of adverse health events. However, current requirements for energy drinks do not apply to energy shots, which remain classified as "natural health products" on the basis that they are "not consumed or perceived as foods" in the same way as energy drinks. An online survey was conducted with Canadian youth and young adults aged 12-24 years (N = 2040) in October 2014 to examine perceptions of energy shots. Respondents viewed an image of a popular energy shot and were asked which term best described it, with six randomly-ordered options. The vast majority (78.8%) perceived the energy shot as an "energy drink" (vs. "supplement", "vitamin drink", "natural health product", "soft drink" or "food product"). Given consumer perceptions and the similarity in product constituents, there is little basis for regulating energy shots differently from energy drinks; these products should be subject to similar labelling and health warning requirements.

  5. Development of Manufacturing Technology to Accelerate Cost Reduction of Low Concentration and

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Detrick, Adam

    The purpose of this project was to accelerate deployment of cost-effective US-based manufacturing of Solaria’s unique c-Si module technology. This effort successfully resulted in the development of US-based manufacturing technology to support two highly-differentiated, market leading product platforms. The project was initially predicated on developing Solaria’s low-concentration PV (LCPV) module technology which at the time of the award was uniquely positioned to exceed the SunShot price goal of $0.50/Wp for standard c-Si modules. The Solaria LCPV module is a 2.5x concentrator that leverages proven, high-reliability PV module materials and low silicon cell usage into a technology package that already hadmore » the lowest direct material cost and leading Levelized Cost of Electricity (LCOE). With over 25 MW commercially deployed globally, the Solaria module was well positioned to continue to lead in PV module cost reduction. Throughout the term of the contract, market conditions changed dramatically and so to did Solaria’s product offerings to support this. However, the manufacturing technology developed for the LCPV module was successfully leveraged and optimized to support two new and different product platforms. BIPV “PowerVision” and High-efficiency “PowerXT” modules. The primary barrier to enabling high-volume PV module manufacturing in the US is the high manual labor component in certain unique aspects of our manufacturing process. The funding was used to develop unique manufacturing automation which makes the manual labor components of these key processes more efficient and increase throughput. At the core of Solaria’s product offerings are its unique and proprietary techniques for dicing and re-arranging solar cells into modules with highly-differentiated characteristics that address key gaps in the c-Si market. It is these techniques that were successfully evolved and deployed into US-based manufacturing site with SunShot funding. Today, Solaria is currently positioned to become the market leader with these two technologies over the coming 24 months largely due to the successful innovations of the underlying manufacturing technology. This success will leverage US-based manufacturing technology and the associated US-jobs to support. Solaria views the project as highly successful and a great example of SunShot funding enabling the creating of US jobs and the deployment of ubiquitous solar energy products.« less

  6. Plague in a Colony of Gunnison's Prairie Dogs ( Cynomys gunnisoni) Despite Three Years of Infusions of Burrows with 0.05% Deltamethrin to Kill Fleas.

    PubMed

    Hoogland, John L; Biggins, Dean E; Blackford, Nathaniel; Eads, David A; Long, Dustin; Rodriguez, Mariana Rivera; Ross, Lauren M; Tobey, Sarah; White, Emma M

    2018-04-01

    At Valles Caldera National Preserve in New Mexico, US, infusing Gunnison's prairie dog ( Cynomys gunnisoni) burrows with an insecticide dust containing 0.05% deltamethrin killed fleas which transmit bubonic plague. The reduction in the number of fleas per prairie dog was significant and dramatic immediately after infusions, with a suggestion that the reduction persisted for as long as 12 mo. Despite the lower flea counts, however, a plague epizootic killed >95% of prairie dogs after 3 yr of infusions (once per year). More research is necessary for a better understanding of the efficacy of insecticide dusts at lowering flea counts and protecting prairie dogs from plague.

  7. A new method of passive counting of nuclear missile warheads -a white paper for the Defense Threat Reduction Agency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, Christopher; Durham, J. Matthew; Guardincerri, Elena

    Cosmic ray muon imaging has been studied for the past several years as a possible technique for nuclear warhead inspection and verification as part of the New Strategic Arms Reduction Treaty between the United States and the Russian Federation. The Los Alamos team has studied two different muon imaging methods for this application, using detectors on two sides and one side of the object of interest. In this report we present results obtained on single sided imaging of configurations aimed at demonstrating the potential of this technique for counting nuclear warheads in place with detectors above the closed hatch ofmore » a ballistic missile submarine.« less

  8. Detection of anthelmintic resistance in sheep and goat against fenbendazole by faecal egg count reduction test.

    PubMed

    Singh, Ramandeep; Bal, M S; Singla, L D; Kaur, Paramjit

    2017-06-01

    Anthelmintic resistance against commonly used anthelmintic fenbendazole was evaluated by employing faecal egg count reduction test (FECRT) in naturally occurring gastrointestinal (GI) nematodes in the semi organized sheep and goat farms of Ludhiana and Amritsar districts. A total of 80 animals (20 each for sheep and goat in both districts) were randomly selected and their faecal samples were examined by qualitative and quantitative parasitological techniques. Results indicate presence of high level of resistance against fenbendazole in both sheep and goat population of Ludhiana and Amritsar districts. More resistance was observed in the GI nematodes from animals reared in Amritsar district as compared to Ludhiana district. The level of anthelmintic resistance observed was apparently more in sheep than goats.

  9. Short-term effects of fire and other fuel reduction treatments on breeding birds in a Southern Appalachian upland hardwood forest

    Treesearch

    Cathryn H. Greenberg; Aimee Livings Tomcho; J. Drew Lanham; Thomas a. Waldrop; Jospeh Tomcho; Ross J. Phillips; Dean Simon

    2007-01-01

    We compared the effects of 3 fuel reduction techniques and a control on breeding birds during 2001–2005 using 50-m point counts. Four experimental units, each .14 ha, were contained within each of 3 replicate blocks at the Green River Game Land, Polk County, North Carolina, USA. Treatments were 1) prescribed burn, 2) mechanical understory reduction (chainsaw-felling...

  10. Field evaluation of the efficacy of common anthelmintics used in the control of gastrointestinal nematodes of sheep in Dabat district, Northwest Ethiopia.

    PubMed

    Seyoum, Zewdu; Demessie, Yitayew; Bogale, Basazinew; Melaku, Achenef

    2017-01-01

    Gastrointestinal nematode (GIN) infections are the main impediments that restrict the welfare and productivity of small ruminant in the world. Effective management of GINs in grazing sheep relies heavily on the use of highly efficacious anthelmintic drugs. However, anthelmintic resistance is becoming a significant concern in the world, and this phenomenon severely threatens the potential utilisation of this control strategy. Therefore, this study was conducted 1) to evaluate the efficacy of commonly used anthelmintic on GINs in naturally infected sheep and 2) to assess the farmers' perception on anthelmintics utilisation practices in Dabat district, Northwest Ethiopia. One hundred twenty nematode infected sheep were used in this study. Sheep were selected based on the egg count (≥150 eggs per gram of faeces). The animals were allocated randomly into four groups (30 animals per group). Group-I, II and III were treated with Albendazole, Tetramisole, and Ivermectin, respectively. The 4th group was left untreated (as control). Faecal samples were collected on day 0 (before treatment), on day 3, 7, 10 and 14 (post-treatment). The modified McMaster technique was used for quantifying the eggs. Faecal egg count reduction test (FECRT) was applied to determine the efficacy of anthelmintic at day 14 (post-treatment). In addition, a questionnaire survey was conducted on 100 randomly selected sheep owners. All anthelmintics tested revealed significant ( P  < 0.05) reduction in nematode egg excretion in the sheep post-treatment. Faecal egg count reduction (FECR) levels for Albendazole, Tetramisole, and Ivermectin were 97.2, 98.9 and 97.7%, respectively. Post-treatment egg counts and percentage reduction of egg counts were not significantly different ( P  > 0.05) among the treatment groups. The nematode genera identified before treatment were Haemonchus , Trichostrongylus , Cooperia , Trichuris , Teladorsagia , Bunostomum, and Strongyloides. Haemonchus and Trichostrongylus were detected after treatment with Albendazole and Ivermectin. The questionnaire survey revealed that Albendazole was the most commonly (90%) used anthelmintic to treat nematodes in sheep, followed by Tetramisole (36%) and Tetraclozan (Tetramisole-Oxyclozanide combination) (20%). Respondents expressed that anthelmintic selection was made based on veterinarian prescription (84%), colour (27%), efficacy (4%), price affordability (1%) and availability (1%). This study demonstrated that the tested anthelmintics had an acceptable level of efficacy against GINs of sheep.

  11. The Effects of Shot and Laser Peening on Fatigue Life and Crack Growth in 2024 Aluminum Alloy and 4340 Steel

    NASA Technical Reports Server (NTRS)

    Everett, R. A., Jr.; Matthews, W. T.; Prabhakaran, R.; Newman, J. C., Jr.; Dubberly, M. J.

    2001-01-01

    Fatigue and crack growth tests have been conducted on 4340 steel and 2024-T3 aluminum alloy, respectively, to assess the effects of shot peening on fatigue life and the effects of shot and laser peening on crack growth. Two current programs involving fixed and rotary-wing aircraft will not be using shot peened structures. Since the shot peening compressive residual stress depth is usually less than the 0.05-inch initial damage tolerance crack size, it is believed by some that shot peening should have no beneficial effects toward retarding crack growth. In this study cracks were initiated from an electronic-discharged machining flaw which was cycled to produce a fatigue crack of approximately 0.05-inches in length and then the specimens were peened. Test results showed that after peening the crack growth rates were noticeably slower when the cracks were fairly short for both the shot and laser peened specimens resulting in a crack growth life that was a factor of 2 to 4 times greater than the results of the average unpeened test. Once the cracks reached a length of approximately 0.1-inches the growth rates were about the same for the peened and unpeened specimens. Fatigue tests on 4340 steel showed that the endurance limit of a test specimen with a 0.002-inch-deep machining-like scratch was reduced by approximately 40 percent. However, if the "scratched" specimen was shot peened after inserting the scratch, the fatigue life returned to almost 100 percent of the unflawed specimens original fatigue life.

  12. Fluid Interactions with Explosion-Induced Fractures

    NASA Astrophysics Data System (ADS)

    Swanson, E.; Sussman, A. J.; Wilson, J.; Broome, S.

    2016-12-01

    Fluids can chemically interact with the fractures they flow through, a process that may affect the movement of fluids in the subsurface. This is a topic of interest to a large variety of research areas, including (but not limited to) production of oil and gas, contaminant tracking, geothermal energy production, CO2 sequestration, and nuclear test monitoring. A study performed as part of the Source Physics Experiment, designed to look at the effects of underground chemical explosions, provides a rare opportunity to compare cores from pre-shot and post-shot rock, from damage created in situ. We present data on the variability of microfracture density with distance from the explosion, as well as the occurrence of fractures that either open or contain clay infill. We find that both open and filled fractures occur more frequently within the post-shot samples (by a factor of up to 4x), with similar spatial distributions. This calls into question the validity of the commonly made assumption that all filled fractures were present prior to the explosive shot, and only open fractures can represent explosion-induced damage. These results suggest that fluid-rock interactions might have a significant influence on the permeabilities that result from explosions, even within a few weeks. Additional data on the mechanical properties of the pre-shot and post-shot core samples show an unexpected pattern during unconfined compressive strength tests: the samples retrieved following 2 successive shots failed at higher stresses than did samples retrieved after 1 shot. We present these results, along with some evidence this behavior may arise from trace differences in water content during testing.

  13. One-shot estimate of MRMC variance: AUC.

    PubMed

    Gallas, Brandon D

    2006-03-01

    One popular study design for estimating the area under the receiver operating characteristic curve (AUC) is the one in which a set of readers reads a set of cases: a fully crossed design in which every reader reads every case. The variability of the subsequent reader-averaged AUC has two sources: the multiple readers and the multiple cases (MRMC). In this article, we present a nonparametric estimate for the variance of the reader-averaged AUC that is unbiased and does not use resampling tools. The one-shot estimate is based on the MRMC variance derived by the mechanistic approach of Barrett et al. (2005), as well as the nonparametric variance of a single-reader AUC derived in the literature on U statistics. We investigate the bias and variance properties of the one-shot estimate through a set of Monte Carlo simulations with simulated model observers and images. The different simulation configurations vary numbers of readers and cases, amounts of image noise and internal noise, as well as how the readers are constructed. We compare the one-shot estimate to a method that uses the jackknife resampling technique with an analysis of variance model at its foundation (Dorfman et al. 1992). The name one-shot highlights that resampling is not used. The one-shot and jackknife estimators behave similarly, with the one-shot being marginally more efficient when the number of cases is small. We have derived a one-shot estimate of the MRMC variance of AUC that is based on a probabilistic foundation with limited assumptions, is unbiased, and compares favorably to an established estimate.

  14. Persistent increase of blood lead level and suppression of δ-ALAD activity in northern bobwhite quail orally dosed with even a single 2-mm spent lead shot.

    PubMed

    Holladay, S D; Kerr, R; Holladay, J P; Meldrum, B; Williams, S M; Gogal, R M

    2012-10-01

    Birds that display grit ingestion behavior are potentially at risk of lead (Pb) poisoning from mistaken ingestion of spent Pb shot pellets. The majority of available studies designed to assess such risk have used unspent shot pellets rather than field-obtained spent shot, which is oxidized and otherwise changed by weathering. Available studies also often administered more or heavier shot pellets to a bird than it might be expected to ingest. The current study dosed northern bobwhite quail (Colinus virginianus) weighing 194.6 ± 23.1 g (female birds) and 199.3 ± 12.2 g (male birds) with one to three spent no. 9 Pb shot collected from a skeet range, with particular interest in the toxicity that may occur from ingestion of a single 2-mm, 50 mg shot. An 8 week post-dosing clinical observation period was employed, over which feed consumption, body weight, blood Pb levels, and a battery of blood physiological parameters were made. Weight loss occurred in the birds, including male birds dosed with one Pb pellet. Erythrocyte delta aminolevulinic acid dehydratase (δ-ALAD) levels were decreased for the duration of the study across exposures and to levels associated with injury in wild bird populations. Decreased ALAD was particularly severe in female birds dosed with one Pb pellet and was still 92 % decreased at 8 weeks after dosing. Together, these results suggest that inadvertent ingestion of a single no. 9 Pb shot pellet can adversely affect the health of northern bobwhite quail.

  15. The reliability and internal consistency of one-shot and flicker change detection for measuring individual differences in visual working memory capacity.

    PubMed

    Pailian, Hrag; Halberda, Justin

    2015-04-01

    We investigated the psychometric properties of the one-shot change detection task for estimating visual working memory (VWM) storage capacity-and also introduced and tested an alternative flicker change detection task for estimating these limits. In three experiments, we found that the one-shot whole-display task returns estimates of VWM storage capacity (K) that are unreliable across set sizes-suggesting that the whole-display task is measuring different things at different set sizes. In two additional experiments, we found that the one-shot single-probe variant shows improvements in the reliability and consistency of K estimates. In another additional experiment, we found that a one-shot whole-display-with-click task (requiring target localization) also showed improvements in reliability and consistency. The latter results suggest that the one-shot task can return reliable and consistent estimates of VWM storage capacity (K), and they highlight the possibility that the requirement to localize the changed target is what engenders this enhancement. Through a final series of four experiments, we introduced and tested an alternative flicker change detection method that also requires the observer to localize the changing target and that generates, from response times, an estimate of VWM storage capacity (K). We found that estimates of K from the flicker task correlated with estimates from the traditional one-shot task and also had high reliability and consistency. We highlight the flicker method's ability to estimate executive functions as well as VWM storage capacity, and discuss the potential for measuring multiple abilities with the one-shot and flicker tasks.

  16. Preoperative Disinfection of Surgeons' Hands: Use of Alcoholic Solutions and Effects of Gloves on Skin Flora

    PubMed Central

    Lowbury, E. J. L.; Lilly, H. A.; Ayliffe, G. A. J.

    1974-01-01

    A single application of about 10 ml of 95% alcoholic chlorhexidine (0·5%) or tetrabrom-o-methyl phenol (0·1%) rubbed on to the hands until they were dry led to mean reduction in viable bacterial counts from standard handwashings of 97·9 ± 1·09% and 91·8 ± 4·63% respectively. After six of such treatments, three on each of two successive days, the mean reductions in relation to viable counts before the first treatment were 99·7 ± 0·09% for alcoholic chlorhexidine and 99·5 ± 0·17% for tetrabrom-o-methyl phenol. These reductions were greater than those obtained with 4% chlorhexidine detergent solution— 87·1 ± 3·5% and 98·2 ± 1·6%, and with 95% or 70% ethyl alcohol and with aqueous 0·5% chlorhexidine. Preoperative washing of the surgeon's hands with alcoholic chlorhexidine used without addition of water is more effective and less expensive than handwashing with antiseptic detergent preparations and running water. The viable counts of washings from hands treated with various antiseptics, including ethyl alcohol, were lower in relation to the pretreatment levels when gloves had been worn for three hours than when samples for counts were taken immediately after the antiseptic treatment. No such difference was found in samplings from hands washed with unmedicated soap. Tests for residual action of antiseptics on the skin showed a greater effect with alcoholic chlorhexidine than with tetrabrom-o-methyl phenol, though both showed greater residual activity than an Irgasan DP 300 detergent preparation. No residual action was shown after 70% ethyl alcohol. PMID:4609555

  17. FINESSE

    Science.gov Websites

    Screen Shot 2016-01-26 at 4.17.19 PM SSERVI / Exploration Science Forum July 2016 The Exploration Science Moon, Near Earth Asteroids, and Phobos & Deimos. Screen Shot 2016-07-07 at 3.43.02 PM Third System. Screen Shot 2016-01-26 at 4.15.52 PM Craters of the Moon National Monument & Preserve (COTM

  18. 3D Visual Proxemics: Recognizing Human Interactions in 3D from a Single Image (Open Access)

    DTIC Science & Technology

    2013-06-28

    accurate tracking and identity associations of people’s motions in videos. Proxemics is a subfield of anthropology that involves study of people...cinematography where the shot composition and camera viewpoint is optimized for visual weight [1]. In cinema , a shot is either a long shot, a medium

  19. 30 CFR 57.22606 - Explosive materials and blasting units (III mines).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... gassy environment. The notice shall also include the millisecond-delay interval between successive shots and between the first and last shot in a round. (b) Faces shall be examined for proper placement of... holes. (c) Multiple-shot blasts shall be initiated with detonators encased in copper-based alloy shells...

  20. 30 CFR 57.22606 - Explosive materials and blasting units (III mines).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... gassy environment. The notice shall also include the millisecond-delay interval between successive shots and between the first and last shot in a round. (b) Faces shall be examined for proper placement of... holes. (c) Multiple-shot blasts shall be initiated with detonators encased in copper-based alloy shells...

  1. 50 CFR 32.67 - Washington.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... nontoxic shot while in the field (see § 32.2(k)). 2. You may not shoot or discharge any firearm from... regulations subject to the following conditions: 1. You may only possess approved nontoxic shot while on the... possess only approved nontoxic shot while on the refuge. 2. We allow only shotguns and archery hunting. 3...

  2. Effects of Laser Peening, and Shot Peening, on Friction Stir Welding

    NASA Technical Reports Server (NTRS)

    Hatamleh, Omar; Hackel, Lloyd; Rankin, Jon; Truong, Chanh; Walter, Matt

    2006-01-01

    A viewgraph presentation describing the effects of laser peening and shot peening on friction stir welding is shown. The topics include: 1) Background; 2) Friction Stir Welding (FSW); 3) Microstructure; 4) Laser & Shot Peening; 5) Residual Stresses; 6) Tensile Behavior; 7) Fatigue Life & Surface Roughness; 8) Crack Growth; and 9) Benefits.

  3. Tdap Vaccine (Tetanus, Diphtheria and Pertussis): What You Need to Know

    MedlinePlus

    ... in 3 adults) • Redness or swelling where the shot was given (about 1 person in 5) • Mild fever of at least ... Pain where the shot was given (up to 1 in 5 or 6) • Redness or swelling where the shot was given (up to about 1 in 16 ...

  4. 50 CFR 32.35 - Kansas.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... 2. Hunters may possess only approved nontoxic shot (see § 32.2(k)). 3. We prohibit the use of... extended white-tailed deer antlerless season in January. 3. We require the use of approved nontoxic shot... upland game. 4. We require the use of approved nontoxic shot (see § 32.2(k)). C. Big Game Hunting. We...

  5. 30 CFR 57.22606 - Explosive materials and blasting units (III mines).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... gassy environment. The notice shall also include the millisecond-delay interval between successive shots and between the first and last shot in a round. (b) Faces shall be examined for proper placement of... holes. (c) Multiple-shot blasts shall be initiated with detonators encased in copper-based alloy shells...

  6. 50 CFR 32.35 - Kansas.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... 2. Hunters may possess only approved nontoxic shot (see § 32.2(k)). 3. We prohibit the use of... extended white-tailed deer antlerless season in January. 3. We require the use of approved nontoxic shot... upland game. 4. We require the use of approved nontoxic shot (see § 32.2(k)). C. Big Game Hunting. We...

  7. 30 CFR 57.22606 - Explosive materials and blasting units (III mines).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... gassy environment. The notice shall also include the millisecond-delay interval between successive shots and between the first and last shot in a round. (b) Faces shall be examined for proper placement of... holes. (c) Multiple-shot blasts shall be initiated with detonators encased in copper-based alloy shells...

  8. Space based lidar shot pattern targeting strategies for small targets such as streams

    NASA Technical Reports Server (NTRS)

    Spiers, Gary D.

    2001-01-01

    An analysis of the effectiveness of four different types of lidar shot distribution is conducted to determine which is best for concentrating shots in a given location. A simple preemptive targeting strategy is found to work as adequately as a more involved dynamic strategy for most target sizes considered.

  9. 50 CFR 32.55 - Oklahoma.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... hunt duck during designated refuge seasons. 6. You may only possess approved nontoxic shot while in the... during designated refuge seasons. 4. Shotgun hunters may only possess approved nontoxic shot while in the... shot while in the field (see § 32.2(k)). 2. We require hunters to check-in and out of the refuge. 3...

  10. 50 CFR 32.32 - Illinois.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... hunter(s) moving through an area with the intent of displacing one or more deer in the direction of... nontoxic shot shells while in the field, including shot shells used for hunting wild turkey (see § 32.2(k... regulations subject to the following conditions: 1. You may only possess approved nontoxic shot while hunting...

  11. 50 CFR 32.35 - Kansas.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... 2. Hunters may possess only approved nontoxic shot (see § 32.2(k)). 3. We prohibit the use of... extended white-tailed deer antlerless season in January. 3. We require the use of approved nontoxic shot... upland game. 4. We require the use of approved nontoxic shot (see § 32.2(k)). C. Big Game Hunting. We...

  12. 16 CFR § 1500.17 - Banned hazardous substances.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) Voluntary standard. (1) One alternative to the tip-angle requirement that the Commission considered is to... Multiple Shot requires that large multiple-tube devices not tip over (except as the result of the last shot) when shot on a 2-inch thick medium-density foam pad. The Commission cannot conclude that AFSL's...

  13. 50 CFR 32.67 - Washington.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... prohibit overnight parking and/or camping. 2. You may possess only approved nontoxic shot for hunting (see.../or parking. 2. You may possess only approved nontoxic shot for hunting (see § 32.2(k)). 3. We... approved nontoxic shot for hunting (see § 32.2(k)). 3. We prohibit discharge of any firearm within 1/4 mile...

  14. 30 CFR 57.22606 - Explosive materials and blasting units (III mines).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... gassy environment. The notice shall also include the millisecond-delay interval between successive shots and between the first and last shot in a round. (b) Faces shall be examined for proper placement of... holes. (c) Multiple-shot blasts shall be initiated with detonators encased in copper-based alloy shells...

  15. Data driven models of the performance and repeatability of NIF high foot implosions

    NASA Astrophysics Data System (ADS)

    Gaffney, Jim; Casey, Dan; Callahan, Debbie; Hartouni, Ed; Ma, Tammy; Spears, Brian

    2015-11-01

    Recent high foot (HF) inertial confinement fusion (ICF) experiments performed at the national ignition facility (NIF) have consisted of enough laser shots that a data-driven analysis of capsule performance is feasible. In this work we use 20-30 individual implosions of similar design, spanning laser drive energies from 1.2 to 1.8 MJ, to quantify our current understanding of the behavior of HF ICF implosions. We develop a probabilistic model for the projected performance of a given implosion and use it to quantify uncertainties in predicted performance including shot-shot variations and observation uncertainties. We investigate the statistical significance of the observed performance differences between different laser pulse shapes, ablator materials, and capsule designs. Finally, using a cross-validation technique, we demonstrate that 5-10 repeated shots of a similar design are required before real trends in the data can be distinguished from shot-shot variations. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. LLNL-ABS-674957.

  16. Adaptation of the FLU-FOBT Program for a primary care clinic serving a low-income Chinese American community: new evidence of effectiveness.

    PubMed

    Potter, Michael B; Yu, Tina M; Gildengorin, Ginny; Yu, Albert Y; Chan, Kit; McPhee, Stephen J; Green, Lawrence W; Walsh, Judith M

    2011-02-01

    We sought to adapt and evaluate the FLU-FOBT Program for a primary care clinic serving a low-income Chinese American community. We compared colorectal cancer screening (CRCS) rate changes for patients who received flu shots versus those who did not receive flu shots during the FLU-FOBT Program. Analysis of data from the year prior to the intervention was used to validate the results. Rates of CRCS increased by 18.0 percentage points for flu shot recipients during the FLU-FOBT Program vs. 1.7 percentage points for flu shot non-recipients (p<.001 for change difference). In the year prior to the FLU-FOBT Program, flu shot recipients had only a 3.3 percentage point increase in the CRCS rate vs. a 1.9 percentage point decline for flu shot non-recipients (p=.08 for change difference). The FLU-FOBT Program as adapted was effective at increasing CRCS rates for primary care patients in this low-income Chinese American community.

  17. Full report of laser doppler velocimetry (Het-V) data, results , and analysis for pRad shot 0632

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tupa, Dale; Tainter, Amy Marie

    This was a collaborative shot with AWE investigators Paul Willis-Patel, David Bell, Seth Grant, David Tarr, and James Richley. The shot was assembled in Los Alamos, after which David Bell set up the probe holder and finalized the alignment. The probe holder location and configuration was modified from previous years to make room for the laser illuminated visible imaging diagnostic. The LANL pRad PDV team was Dale Tupa, Amy Tainter, and Patrick Medina. This shot had three PDV probes: one aimed at the center, one aimed at a feature, one aimed at the reverse side of the shot. The shotmore » also had 9 points of a spectroscopy diagnostic. The pRad team helped set up and field the spectroscopy, but did not help with any data analysis. (The support documentation for the PDV results includes a timing map for the spectroscopy.) Please direct questions on the velocimetry to Dale Tupa or Amy Tainter. The shot radiographs were classified, but the data from the optical diagnostics are not.« less

  18. Damage threshold of platinum coating used for optics for self-seeding of soft x-ray free electron laser

    DOE PAGES

    Krzywinski, Jacek; Cocco, Daniele; Moeller, Stefan; ...

    2015-02-23

    We investigated the experimental damage threshold of platinum coating on a silicon substrate illuminated by soft x-ray radiation at grazing incidence angle of 2.1 deg. The coating was the same as the blazed grating used for the soft X-ray self-seeding optics of the Linac Coherent Light Source free electron laser. The irradiation condition was chosen such that the absorbed dose was similar to the maximum dose expected for the grating. The expected dose was simulated by solving the Helmholtz equation in non-homogenous media. The experiment was performed at 900 eV photon energy for both single pulse and multi-shot conditions. Wemore » have not observed single shot damage. This corresponds to a single shot damage threshold being higher than 3 J/cm 2. The multiple shot damage threshold measured for 10 shots and about 600 shots was determined to be 0.95 J/cm 2 and 0.75 J/cm 2 respectively. The damage threshold occurred at an instantaneous dose which is higher that the melt dose of platinum.« less

  19. Analysis of Tactical, Decisional and Executional Behaviour according to the Level of Expertise in Squash

    PubMed Central

    Catalán-Eslava, María; González-Víllora, Sixto; Pastor-Vicedo, Juan C.; Contreras-Jordán, Onofre R.

    2018-01-01

    Abstract The objective of this study was to analyse the differences in tactical principles, decision-making and execution of the return shot and drop shot of squash players at different levels of proficiency. The sample was composed of 80 players, divided into four levels of expertise (first national category, second national category, autonomous regional level and provincial level). The Squash Performance Evaluation Tool was used for recording the level of decision-making and execution. The results revealed that reading of the context of the game improved as the level of the player’s expertise of both the return shot and the drop shot increased. The correlation between correct decision-making and better quality execution for both the return shot and the drop shot in squash also improved with the player’s level of expertise. According to these results, improvements in situational tactical principles and the application of tactical principles, correct decision-making and high-quality execution are essential to develop the athletic performance level among squash players. PMID:29599875

  20. Practical quantum random number generator based on measuring the shot noise of vacuum states

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen Yong; Zou Hongxin; Tian Liang

    2010-06-15

    The shot noise of vacuum states is a kind of quantum noise and is totally random. In this paper a nondeterministic random number generation scheme based on measuring the shot noise of vacuum states is presented and experimentally demonstrated. We use a homodyne detector to measure the shot noise of vacuum states. Considering that the frequency bandwidth of our detector is limited, we derive the optimal sampling rate so that sampling points have the least correlation with each other. We also choose a method to extract random numbers from sampling values, and prove that the influence of classical noise canmore » be avoided with this method so that the detector does not have to be shot-noise limited. The random numbers generated with this scheme have passed ent and diehard tests.« less

Top