DOE Office of Scientific and Technical Information (OSTI.GOV)
Santoro, J. P.; McNamara, J.; Yorke, E.
2012-10-15
Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged imagesmore » for determining tumor deviations. Methods: Eleven stage II-IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction, seven required a single correction, one required two corrections, and one required three corrections. Mean residual GTV deviation (3D distance) following GTV-based systematic correction (mean {+-} 1 standard deviation 4.8 {+-} 1.5 mm) is significantly lower than for systematic skeletal-based (6.5 {+-} 2.9 mm, p= 0.015), and weekly skeletal-based correction (7.2 {+-} 3.0 mm, p= 0.001), but is not significantly lower than daily skeletal-based correction (5.4 {+-} 2.6 mm, p= 0.34). In two cases, first-day CBCT images reveal tumor changes-one showing tumor growth, the other showing large tumor displacement-that are not readily observed in radiographs. Differences in computed GTV deviations between respiration-correlated and respiration-averaged images are 0.2 {+-} 1.8 mm in the superior-inferior direction and are of similar magnitude in the other directions. Conclusions: An off-line protocol to correct GTV-based systematic error in locally advanced lung tumor cases can be effective at reducing tumor deviations, although the findings need confirmation with larger patient statistics. In some cases, a single cone-beam CT can be useful for assessing tumor changes early in treatment, if more than a few days elapse between simulation and the start of treatment. Tumor deviations measured with respiration-averaged CT and CBCT images are consistent with those measured with respiration-correlated images; the respiration-averaged method is more easily implemented in the clinic.« less
Nasal Septal Deviations: A Systematic Review of Classification Systems.
Teixeira, Jeffrey; Certal, Victor; Chang, Edward T; Camacho, Macario
2016-01-01
Objective. To systematically review the international literature for internal nasal septal deviation classification systems and summarize them for clinical and research purposes. Data Sources. Four databases (including PubMed/MEDLINE) were systematically searched through December 16, 2015. Methods. Systematic review, adhering to PRISMA. Results. After removal of duplicates, this study screened 952 articles for relevance. A final comprehensive review of 50 articles identified that 15 of these articles met the eligibility criteria. The classification systems defined in these articles included C-shaped, S-shaped, reverse C-shaped, and reverse S-shaped descriptions of the septal deviation in both the cephalocaudal and anteroposterior dimensions. Additional studies reported use of computed tomography and categorized deviation based on predefined locations. Three studies graded the severity of septal deviations based on the amount of deflection. The systems defined in the literature also included an evaluation of nasal septal spurs and perforations. Conclusion. This systematic review ascertained that the majority of the currently published classification systems for internal nasal septal deviations can be summarized by C-shaped or reverse C-shaped, as well as S-shaped or reverse S-shaped deviations in the anteroposterior and cephalocaudal dimensions. For imaging studies, predefined points have been defined along the septum. Common terminology can facilitate future research.
Ground state properties of 3d metals from self-consistent GW approach
Kutepov, Andrey L.
2017-10-06
The self consistent GW approach (scGW) has been applied to calculate the ground state properties (equilibrium Wigner–Seitz radius S WZ and bulk modulus B) of 3d transition metals Sc, Ti, V, Fe, Co, Ni, and Cu. The approach systematically underestimates S WZ with average relative deviation from the experimental data of about 1% and it overestimates the calculated bulk modulus with relative error of about 25%. We show that scGW is superior in accuracy as compared to the local density approximation but it is less accurate than the generalized gradient approach for the materials studied. If compared to the randommore » phase approximation, scGW is slightly less accurate, but its error for 3d metals looks more systematic. Lastly, the systematic nature of the deviation from the experimental data suggests that the next order of the perturbation theory should allow one to reduce the error.« less
Ground state properties of 3d metals from self-consistent GW approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kutepov, Andrey L.
The self consistent GW approach (scGW) has been applied to calculate the ground state properties (equilibrium Wigner–Seitz radius S WZ and bulk modulus B) of 3d transition metals Sc, Ti, V, Fe, Co, Ni, and Cu. The approach systematically underestimates S WZ with average relative deviation from the experimental data of about 1% and it overestimates the calculated bulk modulus with relative error of about 25%. We show that scGW is superior in accuracy as compared to the local density approximation but it is less accurate than the generalized gradient approach for the materials studied. If compared to the randommore » phase approximation, scGW is slightly less accurate, but its error for 3d metals looks more systematic. Lastly, the systematic nature of the deviation from the experimental data suggests that the next order of the perturbation theory should allow one to reduce the error.« less
Wang, Wei-Wei; Dong, Bao-Cheng
2017-11-01
This systematic review applied meta-analytic procedures to evaluate the curative effect of trans-septal suturing versus nasal packing after septoplasty. Computerized search of the published literature in PubMed, EMBASE, CENTRAL, Cochrane Database of Systematic Reviews, WANFANG, CNKI databases. Randomized trials investigating trans-septal suturing versus nasal packing following septoplasty in patients with deviated nasal septum. Adhesion, septal hematoma, bleeding, septal perforation, infection, pain, headache, or residual septal deviation per randomized patients. 19 randomized controlled trials of 1845 subjects were included. Meta-analysis showed that postoperative pain, headache, and adhesion were significantly lower in trans-septal suturing group. Nasal packing and trans-septal suturing technique appear to be equivalent with regard to postoperative bleeding, hematoma, septal perforation, infection, and residual septal deviation. Trans-septal suturing technology is not only associated with less patient pain, headache, and lower occurrence rate of adhesion after septoplasty but it also relates to higher patient satisfaction and an improved quality of life. The suturing technology can be used as a substitute for traditional nasal packing of the first-line treatment. More well-designed studies are needed to confirm the effect of trans-septal suturing following septoplasty.
Raico Gallardo, Yolanda Natali; da Silva-Olivio, Isabela Rodrigues Teixeira; Mukai, Eduardo; Morimoto, Susana; Sesma, Newton; Cordaro, Luca
2017-05-01
To systematically assess the current dental literature comparing the accuracy of computer-aided implant surgery when using different supporting tissues (tooth, mucosa, or bone). Two reviewers searched PubMed (1972 to January 2015) and the Cochrane Central Register of Controlled Trials (Central) (2002 to January 2015). For the assessment of accuracy, studies were included with the following outcome measures: (i) angle deviation, (ii) deviation at the entry point, and (iii) deviation at the apex. Eight clinical studies from the 1602 articles initially identified met the inclusion criteria for the qualitative analysis. Four studies (n = 599 implants) were evaluated using meta-analysis. The bone-supported guides showed a statistically significant greater deviation in angle (P < 0.001), entry point (P = 0.01), and the apex (P = 0.001) when compared to the tooth-supported guides. Conversely, when only retrospective studies were analyzed, not significant differences are revealed in the deviation of the entry point and apex. The mucosa-supported guides indicated a statistically significant greater reduction in angle deviation (P = 0.02), deviation at the entry point (P = 0.002), and deviation at the apex (P = 0.04) when compared to the bone-supported guides. Between the mucosa- and tooth-supported guides, there were no statistically significant differences for any of the outcome measures. It can be concluded that the tissue of the guide support influences the accuracy of computer-aided implant surgery. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Edvardsson, A.; Ceberg, S.
2013-06-01
The aim of this study was 1) to investigate interfraction set-up uncertainties for patients treated with respiratory gating for left-sided breast cancer, 2) to investigate the effect of the inter-fraction set-up on the absorbed dose-distribution for the target and organs at risk (OARs) and 3) optimize the set-up correction strategy. By acquiring multiple set-up images the systematic set-up deviation was evaluated. The effect of the systematic set-up deviation on the absorbed dose distribution was evaluated by 1) simulation in the treatment planning system and 2) measurements with a biplanar diode array. The set-up deviations could be decreased using a no action level correction strategy. Not using the clinically implemented adaptive maximum likelihood factor for the gating patients resulted in better set-up. When the uncorrected set-up deviations were simulated the average mean absorbed dose was increased from 1.38 to 2.21 Gy for the heart, 4.17 to 8.86 Gy to the left anterior descending coronary artery and 5.80 to 7.64 Gy to the left lung. Respiratory gating can induce systematic set-up deviations which would result in increased mean absorbed dose to the OARs if not corrected for and should therefore be corrected for by an appropriate correction strategy.
Bolann, B J; Asberg, A
2004-01-01
The deviation of test results from patients' homeostatic set points in steady-state conditions may complicate interpretation of the results and the comparison of results with clinical decision limits. In this study the total deviation from the homeostatic set point is defined as the maximum absolute deviation for 95% of measurements, and we present analytical quality requirements that prevent analytical error from increasing this deviation to more than about 12% above the value caused by biology alone. These quality requirements are: 1) The stable systematic error should be approximately 0, and 2) a systematic error that will be detected by the control program with 90% probability, should not be larger than half the value of the combined analytical and intra-individual standard deviation. As a result, when the most common control rules are used, the analytical standard deviation may be up to 0.15 times the intra-individual standard deviation. Analytical improvements beyond these requirements have little impact on the interpretability of measurement results.
NASA Astrophysics Data System (ADS)
Kolesnik, Y. B.
1995-12-01
15 catalogues produced in the 1980s and 12 catalogues made from 1960 to 1978 have been used to assess the consistency of the FK5 system with observations in the declination zone from -30deg to 30deg. Classical δ-dependent and α-dependent systematic differences (Cat-FK5) have been formed for individual instrumental systems of the catalogues. The weighted mean instrumental systems for two subsets of catalogues centred at the epochs 1970 and 1987 have been constructed. External systematic and random accuracy of the catalogues under analysis and errors of the mean instrumental systems for both selections of catalogues have been estimated and presented in tables. The individual systematic differences of the catalogues and the mean instrumental systems are shown in figures. Numerical values of the total systematic deviations for both mean instrumental systems are given in tables. The results of intercomparison are discussed to assess the actual systematic deviations of the FK5 at the respective epochs and its actual random accuracy. It has been found that the mutual consistency of individual instrumental systems of catalogues of 1980s with respect to zonal systematic differences in both right ascension and declination is significantly better when comparing with the earlier catalogues. Consistency of both catalogue subsets is comparable with respect to α-dependent systematic differences. It is shown that the claimed random errors of the FK5 positions and proper motions are rather realistic, while deviations of the FK5 right ascension and declination system in the equatorial zone for both mean epochs exceed expected ones from the formal considerations. Quick degradation of the FK5 system with time is detected in right ascension. The results in declination are recognized to be less reliable, due to larger inconsistency of the individual instrumental systems. The system of the Second Quito Astrolabe Catalogue (QAC 2) has been investigated by comparison with two subsets of catalogues. It shows rather good consistency with both mean instrumental systems. Some conspicuous local deviations are outlined and discussed. We conclude that the QAC 2 might successfully be used in the compilation of the future second general catalogue of astrolabes as a link between northern and southern astrolabe catalogues.
Dosimetry audit simulation of treatment planning system in multicenters radiotherapy
NASA Astrophysics Data System (ADS)
Kasmuri, S.; Pawiro, S. A.
2017-07-01
Treatment Planning System (TPS) is an important modality that determines radiotherapy outcome. TPS requires input data obtained through commissioning and the potentially error occurred. Error in this stage may result in the systematic error. The aim of this study to verify the TPS dosimetry to know deviation range between calculated and measurement dose. This study used CIRS phantom 002LFC representing the human thorax and simulated all external beam radiotherapy stages. The phantom was scanned using CT Scanner and planned 8 test cases that were similar to those in clinical practice situation were made, tested in four radiotherapy centers. Dose measurement using 0.6 cc ionization chamber. The results of this study showed that generally, deviation of all test cases in four centers was within agreement criteria with average deviation about -0.17±1.59 %, -1.64±1.92 %, 0.34±1.34 % and 0.13±1.81 %. The conclusion of this study was all TPS involved in this study showed good performance. The superposition algorithm showed rather poor performance than either analytic anisotropic algorithm (AAA) and convolution algorithm with average deviation about -1.64±1.92 %, -0.17±1.59 % and -0.27±1.51 % respectively.
Alcohol consumption for simulated driving performance: A systematic review.
Rezaee-Zavareh, Mohammad Saeid; Salamati, Payman; Ramezani-Binabaj, Mahdi; Saeidnejad, Mina; Rousta, Mansoureh; Shokraneh, Farhad; Rahimi-Movaghar, Vafa
2017-06-01
Alcohol consumption can lead to risky driving and increase the frequency of traffic accidents, injuries and mortalities. The main purpose of our study was to compare simulated driving performance between two groups of drivers, one consumed alcohol and the other not consumed, using a systematic review. In this systematic review, electronic resources and databases including Medline via Ovid SP, EMBASE via Ovid SP, PsycINFO via Ovid SP, PubMed, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINHAL) via EBSCOhost were comprehensively and systematically searched. The randomized controlled clinical trials that compared simulated driving performance between two groups of drivers, one consumed alcohol and the other not consumed, were included. Lane position standard deviation (LPSD), mean of lane position deviation (MLPD), speed, mean of speed deviation (MSD), standard deviation of speed deviation (SDSD), number of accidents (NA) and line crossing (LC) were considered as the main parameters evaluating outcomes. After title and abstract screening, the articles were enrolled for data extraction and they were evaluated for risk of biases. Thirteen papers were included in our qualitative synthesis. All included papers were classified as high risk of biases. Alcohol consumption mostly deteriorated the following performance outcomes in descending order: SDSD, LPSD, speed, MLPD, LC and NA. Our systematic review had troublesome heterogeneity. Alcohol consumption may decrease simulated driving performance in alcohol consumed people compared with non-alcohol consumed people via changes in SDSD, LPSD, speed, MLPD, LC and NA. More well-designed randomized controlled clinical trials are recommended. Copyright © 2017. Production and hosting by Elsevier B.V.
Wan, Xiang; Wang, Wenqian; Liu, Jiming; Tong, Tiejun
2014-12-19
In systematic reviews and meta-analysis, researchers often pool the results of the sample mean and standard deviation from a set of similar clinical trials. A number of the trials, however, reported the study using the median, the minimum and maximum values, and/or the first and third quartiles. Hence, in order to combine results, one may have to estimate the sample mean and standard deviation for such trials. In this paper, we propose to improve the existing literature in several directions. First, we show that the sample standard deviation estimation in Hozo et al.'s method (BMC Med Res Methodol 5:13, 2005) has some serious limitations and is always less satisfactory in practice. Inspired by this, we propose a new estimation method by incorporating the sample size. Second, we systematically study the sample mean and standard deviation estimation problem under several other interesting settings where the interquartile range is also available for the trials. We demonstrate the performance of the proposed methods through simulation studies for the three frequently encountered scenarios, respectively. For the first two scenarios, our method greatly improves existing methods and provides a nearly unbiased estimate of the true sample standard deviation for normal data and a slightly biased estimate for skewed data. For the third scenario, our method still performs very well for both normal data and skewed data. Furthermore, we compare the estimators of the sample mean and standard deviation under all three scenarios and present some suggestions on which scenario is preferred in real-world applications. In this paper, we discuss different approximation methods in the estimation of the sample mean and standard deviation and propose some new estimation methods to improve the existing literature. We conclude our work with a summary table (an Excel spread sheet including all formulas) that serves as a comprehensive guidance for performing meta-analysis in different situations.
Accounting for one-channel depletion improves missing value imputation in 2-dye microarray data.
Ritz, Cecilia; Edén, Patrik
2008-01-19
For 2-dye microarray platforms, some missing values may arise from an un-measurably low RNA expression in one channel only. Information of such "one-channel depletion" is so far not included in algorithms for imputation of missing values. Calculating the mean deviation between imputed values and duplicate controls in five datasets, we show that KNN-based imputation gives a systematic bias of the imputed expression values of one-channel depleted spots. Evaluating the correction of this bias by cross-validation showed that the mean square deviation between imputed values and duplicates were reduced up to 51%, depending on dataset. By including more information in the imputation step, we more accurately estimate missing expression values.
NASA Technical Reports Server (NTRS)
Mehdipour, M.; Kaastra, J. S.; Kallman, T.
2016-01-01
Atomic data and plasma models play a crucial role in the diagnosis and interpretation of astrophysical spectra, thus influencing our understanding of the Universe. In this investigation we present a systematic comparison of the leading photoionization codes to determine how much their intrinsic differences impact X-ray spectroscopic studies of hot plasmas in photoionization equilibrium. We carry out our computations using the Cloudy, SPEX, and XSTAR photoionization codes, and compare their derived thermal and ionization states for various ionizing spectral energy distributions. We examine the resulting absorption-line spectra from these codes for the case of ionized outflows in active galactic nuclei. By comparing the ionic abundances as a function of ionization parameter, we find that on average there is about 30 deviation between the codes in where ionic abundances peak. For H-like to B-like sequence ions alone, this deviation in is smaller at about 10 on average. The comparison of the absorption-line spectra in the X-ray band shows that there is on average about 30 deviation between the codes in the optical depth of the lines produced at log 1 to 2, reducing to about 20 deviation at log 3. We also simulate spectra of the ionized outflows with the current and upcoming high-resolution X-ray spectrometers, on board XMM-Newton, Chandra, Hitomi, and Athena. From these simulations we obtain the deviation on the best-fit model parameters, arising from the use of different photoionization codes, which is about 10 to40. We compare the modeling uncertainties with the observational uncertainties from the simulations. The results highlight the importance of continuous development and enhancement of photoionization codes for the upcoming era of X-ray astronomy with Athena.
Puelacher, Christian; Wagener, Max; Abächerli, Roger; Honegger, Ursina; Lhasam, Nundsin; Schaerli, Nicolas; Prêtre, Gil; Strebel, Ivo; Twerenbold, Raphael; Boeddinghaus, Jasper; Nestelberger, Thomas; Rubini Giménez, Maria; Hillinger, Petra; Wildi, Karin; Sabti, Zaid; Badertscher, Patrick; Cupa, Janosch; Kozhuharov, Nikola; du Fay de Lavallaz, Jeanne; Freese, Michael; Roux, Isabelle; Lohrmann, Jens; Leber, Remo; Osswald, Stefan; Wild, Damian; Zellweger, Michael J; Mueller, Christian; Reichlin, Tobias
2017-07-01
Exercise ECG stress testing is the most widely available method for evaluation of patients with suspected myocardial ischemia. Its major limitation is the relatively poor accuracy of ST-segment changes regarding ischemia detection. Little is known about the optimal method to assess ST-deviations. A total of 1558 consecutive patients undergoing bicycle exercise stress myocardial perfusion imaging (MPI) were enrolled. Presence of inducible myocardial ischemia was adjudicated using MPI results. The diagnostic value of ST-deviations for detection of exercise-induced myocardial ischemia was systematically analyzed 1) for each individual lead, 2) at three different intervals after the J-point (J+40ms, J+60ms, J+80ms), and 3) at different time points during the test (baseline, maximal workload, 2min into recovery). Exercise-induced ischemia was detected in 481 (31%) patients. The diagnostic accuracy of ST-deviations was highest at +80ms after the J-point, and at 2min into recovery. At this point, ST-amplitude showed an AUC of 0.63 (95% CI 0.59-0.66) for the best-performing lead I. The combination of ST-amplitude and ST-slope in lead I did not increase the AUC. Lead I reached a sensitivity of 37% and a specificity of 83%, with similar sensitivity to manual ECG analysis (34%, p=0.31) but lower specificity (90%, p<0.001). When using ECG stress testing for evaluation of patients with suspected myocardial ischemia, the diagnostic accuracy of ST-deviations is highest when evaluated at +80ms after the J-point, and at 2min into recovery. Copyright © 2017 Elsevier B.V. All rights reserved.
Abraha, Iosief; Cozzolino, Francesco; Orso, Massimiliano; Marchesi, Mauro; Germani, Antonella; Lombardo, Guido; Eusebi, Paolo; De Florio, Rita; Luchetta, Maria Laura; Iorio, Alfonso; Montedori, Alessandro
2017-04-01
To describe the characteristics, and estimate the incidence, of trials included in systematic reviews deviating from the intention-to-treat (ITT) principle. A 5% random sample of reviews were selected (Medline 2006-2010). Trials from reviews were classified based on the ITT: (1) ITT trials (trials reporting standard ITT analyses); (2) modified ITT (mITT) trials (modified ITT; trials deviating from standard ITT); or (3) no ITT trials. Of 222 reviews, 81 (36%) included at least one mITT trial. Reviews with mITT trials were more likely to contain trials that used placebo, that investigated drugs, and that reported favorable results. The incidence of reviews with mITT trial ranged from 29% (17/58) to 48% (23/48). Of the 2,349 trials, 597 (25.4%) were classified as ITT trials, 323 (13.8%) as mITT trials, and 1,429 (60.8%) as no ITT trials. The mITT trials were more likely to have reported exclusions compared to studies classified as ITT trials and to have received funding. The reporting of the type of ITT may differ according to the clinical area and the type of intervention. Deviation from ITT in randomized controlled trials is a widespread phenomenon that significantly affects systematic reviews. Copyright © 2017 Elsevier Inc. All rights reserved.
Unaccounted source of systematic errors in measurements of the Newtonian gravitational constant G
NASA Astrophysics Data System (ADS)
DeSalvo, Riccardo
2015-06-01
Many precision measurements of G have produced a spread of results incompatible with measurement errors. Clearly an unknown source of systematic errors is at work. It is proposed here that most of the discrepancies derive from subtle deviations from Hooke's law, caused by avalanches of entangled dislocations. The idea is supported by deviations from linearity reported by experimenters measuring G, similarly to what is observed, on a larger scale, in low-frequency spring oscillators. Some mitigating experimental apparatus modifications are suggested.
NASA Astrophysics Data System (ADS)
Kuruliuk, K. A.; Kulesh, V. P.
2016-10-01
An optical videogrammetry method using one digital camera for non-contact measurements of geometric shape parameters, position and motion of models and structural elements of aircraft in experimental aerodynamics was developed. The tests with the use of this method for measurement of six components (three linear and three angular ones) of real position of helicopter device in wind tunnel flow were conducted. The distance between camera and test object was 15 meters. It was shown in practice that, in the conditions of aerodynamic experiment instrumental measurement error (standard deviation) for angular and linear displacements of helicopter device does not exceed 0,02° and 0.3 mm, respectively. Analysis of the results shows that at the minimum rotor thrust deviations are systematic and generally are within ± 0.2 degrees. Deviations of angle values grow with the increase of rotor thrust.
Ismail, Shiek Abdullah; Button, Kate; Simic, Milena; Van Deursen, Robert; Pappas, Evangelos
2016-06-01
Altered joint motion that occurs in people with an anterior cruciate ligament deficient knee is proposed to play a role in the initiation of knee osteoarthritis, however, the exact mechanism is poorly understood. Although several studies have investigated gait deviations in individuals with chronic anterior cruciate ligament deficient knee in the frontal and transverse planes, no systematic review has summarized the kinematic and kinetic deviations in these two planes. We searched five electronic databases from inception to 14th October 2013, with key words related to anterior cruciate ligament, biomechanics and gait, and limited to human studies only. Two independent reviewers assessed eligibility based on predetermined inclusion/exclusion criteria and methodological quality was evaluated using the Strengthening the Reporting of Observational Studies in Epidemiology statement checklist. We identified 16 studies, totaling 183 subjects with anterior cruciate ligament deficient knee and 211 healthy subjects. Due to the variability in reported outcomes, we could only perform meta-analysis for 13 sagittal plane outcomes. The only significant finding from our meta-analysis showed that individuals with anterior cruciate ligament deficient knee demonstrated a significantly greater external hip flexor angular impulse compared to control (P=0.03). No consensus about what constitutes a typical walking pattern in individuals with anterior cruciate ligament deficient knee can be made, nor can conclusions be derived to explain if gait deviations in the frontal and transverse plane contributed to the development of the knee osteoarthritis among this population. Copyright © 2016 Elsevier Ltd. All rights reserved.
Repp, B H
1999-04-01
The detectability of a deviation from metronomic timing--of a small local increment in interonset interval (IOI) duration--in a musical excerpt is subject to positional biases, or "timing expectations," that are closely related to the expressive timing (sequence of IOI durations) typically produced by musicians in performance (Repp, 1992b, 1998c, 1998d). Experiment 1 replicated this finding with some changes in procedure and showed that the perception-performance correlation is not the result of formal musical training or availability of a musical score. Experiments 2 and 3 used a synchronization task to examine the hypothesis that participants' perceptual timing expectations are due to systematic modulations in the period of a mental timekeeper that also controls perceptual-motor coordination. Indeed, there was systematic variation in the asynchronies between taps and metronomically timed musical event onsets, and this variation was correlated both with the variations in IOI increment detectability (Experiment 1) and with the typical expressive timing pattern in performance. When the music contained local IOI increments (Experiment 2), they were almost perfectly compensated for on the next tap, regardless of their detectability in Experiment 1, which suggests a perceptual-motor feedback mechanism that is sensitive to subthreshold timing deviations. Overall, the results suggest that aspects of perceived musical structure influence the predictions of mental timekeeping mechanisms, thereby creating a subliminal warping of experienced time.
More reliable inference for the dissimilarity index of segregation
Allen, Rebecca; Burgess, Simon; Davidson, Russell; Windmeijer, Frank
2015-01-01
Summary The most widely used measure of segregation is the so‐called dissimilarity index. It is now well understood that this measure also reflects randomness in the allocation of individuals to units (i.e. it measures deviations from evenness, not deviations from randomness). This leads to potentially large values of the segregation index when unit sizes and/or minority proportions are small, even if there is no underlying systematic segregation. Our response to this is to produce adjustments to the index, based on an underlying statistical model. We specify the assignment problem in a very general way, with differences in conditional assignment probabilities underlying the resulting segregation. From this, we derive a likelihood ratio test for the presence of any systematic segregation, and bias adjustments to the dissimilarity index. We further develop the asymptotic distribution theory for testing hypotheses concerning the magnitude of the segregation index and show that the use of bootstrap methods can improve the size and power properties of test procedures considerably. We illustrate these methods by comparing dissimilarity indices across school districts in England to measure social segregation. PMID:27774035
SDSS-IV MaNGA: a distinct mass distribution explored in slow-rotating early-type galaxies
NASA Astrophysics Data System (ADS)
Rong, Yu; Li, Hongyu; Wang, Jie; Gao, Liang; Li, Ran; Ge, Junqiang; Jing, Yingjie; Pan, Jun; Fernández-Trincado, J. G.; Valenzuela, Octavio; Ortíz, Erik Aquino
2018-06-01
We study the radial acceleration relation (RAR) for early-type galaxies (ETGs) in the SDSS MaNGA MPL5 data set. The complete ETG sample show a slightly offset RAR from the relation reported by McGaugh et al. (2016) at the low-acceleration end; we find that the deviation is due to the fact that the slow rotators show a systematically higher acceleration relation than the McGaugh's RAR, while the fast rotators show a consistent acceleration relation to McGaugh's RAR. There is a 1σ significant difference between the acceleration relations of the fast and slow rotators, suggesting that the acceleration relation correlates with the galactic spins, and that the slow rotators may have a different mass distribution compared with fast rotators and late-type galaxies. We suspect that the acceleration relation deviation of slow rotators may be attributed to more galaxy merger events, which would disrupt the original spins and correlated distributions of baryons and dark matter orbits in galaxies.
Normal correspondence of tectal maps for saccadic eye movements in strabismus
Economides, John R.; Adams, Daniel L.
2016-01-01
The superior colliculus is a major brain stem structure for the production of saccadic eye movements. Electrical stimulation at any given point in the motor map generates saccades of defined amplitude and direction. It is unknown how this saccade map is affected by strabismus. Three macaques were raised with exotropia, an outwards ocular deviation, by detaching the medial rectus tendon in each eye at age 1 mo. The animals were able to make saccades to targets with either eye and appeared to alternate fixation freely. To probe the organization of the superior colliculus, microstimulation was applied at multiple sites, with the animals either free-viewing or fixating a target. On average, microstimulation drove nearly conjugate saccades, similar in both amplitude and direction but separated by the ocular deviation. Two monkeys showed a pattern deviation, characterized by a systematic change in the relative position of the two eyes with certain changes in gaze angle. These animals' saccades were slightly different for the right eye and left eye in their amplitude or direction. The differences were consistent with the animals' underlying pattern deviation, measured during static fixation and smooth pursuit. The tectal map for saccade generation appears to be normal in strabismus, but saccades may be affected by changes in the strabismic deviation that occur with different gaze angles. PMID:27605534
First Local Ties from Data of the Wettzell Triple Radio Telescope Array
NASA Astrophysics Data System (ADS)
Schüler, T.; Plötz, C.; Mähler, S.; Klügel, T.; Neidhardt, A.; Bertarini, A.; Halsig, S.; Nothnagel, A.; Lösler, M.; Eschelbach, C.; Anderson, J.
2016-12-01
The Geodetic Observatory Wettzell features three radio telescopes. Local ties between the reference points are available from terrestrial precision surveying with an expected accuracy below 0.7 mm. In addition, local VLBI data analysis is currently investigated to provide independent vectors and to provide quality feedback to the engineers. The preliminary results presented in this paper show a deviation from the local survey at the level of one millimeter with a clear systematic component. Sub-millimeter precision is reached after removal of this bias. This systematic effect is likely caused by omission of thermal expansion and gravity deformation, which is not yet implemented in our local VLBI analysis software.
Schrems, W A; Laemmer, R; Hoesl, L M; Horn, F K; Mardin, C Y; Kruse, F E; Tornow, R P
2011-10-01
To investigate the influence of atypical retardation pattern (ARP) on the distribution of peripapillary retinal nerve fibre layer (RNFL) thickness measured with scanning laser polarimetry in healthy individuals and to compare these results with RNFL thickness from spectral domain optical coherence tomography (OCT) in the same subjects. 120 healthy subjects were investigated in this study. All volunteers received detailed ophthalmological examination, GDx variable corneal compensation (VCC) and Spectralis-OCT. The subjects were divided into four subgroups according to their typical scan score (TSS): very typical with TSS=100, typical with 99 ≥ TSS ≥ 91, less typical with 90 ≥ TSS ≥ 81 and atypical with TSS ≤ 80. Deviations from very typical normal values were calculated for 32 sectors for each group. There was a systematic variation of the RNFL thickness deviation around the optic nerve head in the atypical group for the GDxVCC results. The highest percentage deviation of about 96% appeared temporal with decreasing deviation towards the superior and inferior sectors, and nasal sectors exhibited a deviation of 30%. Percentage deviations from very typical RNFL values decreased with increasing TSS. No systematic variation could be found if the RNFL thickness deviation between different TSS-groups was compared with the OCT results. The ARP has a major impact on the peripapillary RNFL distribution assessed by GDx VCC; thus, the TSS should be included in the standard printout.
Abraha, Iosief; Cherubini, Antonio; Cozzolino, Francesco; De Florio, Rita; Luchetta, Maria Laura; Rimland, Joseph M; Folletti, Ilenia; Marchesi, Mauro; Germani, Antonella; Orso, Massimiliano; Eusebi, Paolo; Montedori, Alessandro
2015-05-27
To examine whether deviation from the standard intention to treat analysis has an influence on treatment effect estimates of randomised trials. Meta-epidemiological study. Medline, via PubMed, searched between 2006 and 2010; 43 systematic reviews of interventions and 310 randomised trials were included. From each year searched, random selection of 5% of intervention reviews with a meta-analysis that included at least one trial that deviated from the standard intention to treat approach. Basic characteristics of the systematic reviews and randomised trials were extracted. Information on the reporting of intention to treat analysis, outcome data, risk of bias items, post-randomisation exclusions, and funding were extracted from each trial. Trials were classified as: ITT (reporting the standard intention to treat approach), mITT (reporting a deviation from the standard approach), and no ITT (reporting no approach). Within each meta-analysis, treatment effects were compared between mITT and ITT trials, and between mITT and no ITT trials. The ratio of odds ratios was calculated (value <1 indicated larger treatment effects in mITT trials than in other trial categories). 50 meta-analyses and 322 comparisons of randomised trials (from 84 ITT trials, 118 mITT trials, and 108 no ITT trials; 12 trials contributed twice to the analysis) were examined. Compared with ITT trials, mITT trials showed a larger intervention effect (pooled ratio of odds ratios 0.83 (95% confidence interval 0.71 to 0.96), P=0.01; between meta-analyses variance τ(2)=0.13). Adjustments for sample size, type of centre, funding, items of risk of bias, post-randomisation exclusions, and variance of log odds ratio yielded consistent results (0.80 (0.69 to 0.94), P=0.005; τ(2)=0.08). After exclusion of five influential studies, results remained consistent (0.85 (0.75 to 0.98); τ(2)=0.08). The comparison between mITT trials and no ITT trials showed no statistical difference between the two groups (adjusted ratio of odds ratios 0.92 (0.70 to 1.23); τ(2)=0.57). Trials that deviated from the intention to treat analysis showed larger intervention effects than trials that reported the standard approach. Where an intention to treat analysis is impossible to perform, authors should clearly report who is included in the analysis and attempt to perform multiple imputations. © Abraha et al 2015.
MUSiC - A general search for deviations from monte carlo predictions in CMS
NASA Astrophysics Data System (ADS)
Biallass, Philipp A.; CMS Collaboration
2009-06-01
A model independent analysis approach in CMS is presented, systematically scanning the data for deviations from the Monte Carlo expectation. Such an analysis can contribute to the understanding of the detector and the tuning of the event generators. Furthermore, due to the minimal theoretical bias this approach is sensitive to a variety of models of new physics, including those not yet thought of. Events are classified into event classes according to their particle content (muons, electrons, photons, jets and missing transverse energy). A broad scan of various distributions is performed, identifying significant deviations from the Monte Carlo simulation. The importance of systematic uncertainties is outlined, which are taken into account rigorously within the algorithm. Possible detector effects and generator issues, as well as models involving Supersymmetry and new heavy gauge bosons are used as an input to the search algorithm.
MUSiC - A Generic Search for Deviations from Monte Carlo Predictions in CMS
NASA Astrophysics Data System (ADS)
Hof, Carsten
2009-05-01
We present a model independent analysis approach, systematically scanning the data for deviations from the Standard Model Monte Carlo expectation. Such an analysis can contribute to the understanding of the CMS detector and the tuning of the event generators. Furthermore, due to the minimal theoretical bias this approach is sensitive to a variety of models of new physics, including those not yet thought of. Events are classified into event classes according to their particle content (muons, electrons, photons, jets and missing transverse energy). A broad scan of various distributions is performed, identifying significant deviations from the Monte Carlo simulation. We outline the importance of systematic uncertainties, which are taken into account rigorously within the algorithm. Possible detector effects and generator issues, as well as models involving supersymmetry and new heavy gauge bosons have been used as an input to the search algorithm.
MUSiC - Model-independent search for deviations from Standard Model predictions in CMS
NASA Astrophysics Data System (ADS)
Pieta, Holger
2010-02-01
We present an approach for a model independent search in CMS. Systematically scanning the data for deviations from the standard model Monte Carlo expectations, such an analysis can help to understand the detector and tune event generators. By minimizing the theoretical bias the analysis is furthermore sensitive to a wide range of models for new physics, including the uncounted number of models not-yet-thought-of. After sorting the events into classes defined by their particle content (leptons, photons, jets and missing transverse energy), a minimally prejudiced scan is performed on a number of distributions. Advanced statistical methods are used to determine the significance of the deviating regions, rigorously taking systematic uncertainties into account. A number of benchmark scenarios, including common models of new physics and possible detector effects, have been used to gauge the power of such a method. )
Simulation study on combination of GRACE monthly gravity field solutions
NASA Astrophysics Data System (ADS)
Jean, Yoomin; Meyer, Ulrich; Jäggi, Adrian
2016-04-01
The GRACE monthly gravity fields from different processing centers are combined in the frame of the project EGSIEM. This combination is done on solution level first to define weights which will be used for a combination on normal equation level. The applied weights are based on the deviation of the individual gravity fields from the arithmetic mean of all involved gravity fields. This kind of weighting scheme relies on the assumption that the true gravity field is close to the arithmetic mean of the involved individual gravity fields. However, the arithmetic mean can be affected by systematic errors in individual gravity fields, which consequently results in inappropriate weights. For the future operational scientific combination service of GRACE monthly gravity fields, it is necessary to examine the validity of the weighting scheme also in possible extreme cases. To investigate this, we make a simulation study on the combination of gravity fields. Firstly, we show how a deviated gravity field can affect the combined solution in terms of signal and noise in the spatial domain. We also show the impact of systematic errors in individual gravity fields on the resulting combined solution. Then, we investigate whether the weighting scheme still works in the presence of outliers. The result of this simulation study will be useful to understand and validate the weighting scheme applied to the combination of the monthly gravity fields.
MUSiC—An Automated Scan for Deviations between Data and Monte Carlo Simulation
NASA Astrophysics Data System (ADS)
Meyer, Arnd
2010-02-01
A model independent analysis approach is presented, systematically scanning the data for deviations from the standard model Monte Carlo expectation. Such an analysis can contribute to the understanding of the CMS detector and the tuning of event generators. The approach is sensitive to a variety of models of new physics, including those not yet thought of.
MUSiC - An Automated Scan for Deviations between Data and Monte Carlo Simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyer, Arnd
2010-02-10
A model independent analysis approach is presented, systematically scanning the data for deviations from the standard model Monte Carlo expectation. Such an analysis can contribute to the understanding of the CMS detector and the tuning of event generators. The approach is sensitive to a variety of models of new physics, including those not yet thought of.
Marlière, Daniel Amaral Alves; Demétrio, Maurício Silva; Picinini, Leonardo Santos; De Oliveira, Rodrigo Guerra; Chaves Netto, Henrique Duque De Miranda
2018-01-01
Assess clinical studies regarding accuracy between virtual planning of computer-guided surgery and actual outcomes of dental implant placements in total edentulous alveolar ridges. A PubMed search was performed to identify only clinical studies published between 2011 and 2016, searching the following combinations of keywords: “Accuracy AND Computer-Assisted Surgery AND Dental Implants.” Study designs were identified using the terms: Case Reports, Clinical study, Randomized Controlled Trial, Systematic Reviews, Meta-Analysis, humans. Level of agreement between the authors in the study selection process was substantial (k = 0.767), and the study eligibility was considered excellent (k = 0.863). Seven articles were included in this review. They describe the use of bone and muco-supported guides, demonstrating angular deviations cervically and apically ranging from (minimum and maximum means), respectively, 1.85–8.4 (°), 0.17–2.17 (mm), and 0.77–2.86 (mm). Angular deviations obtained most inaccuracy in maxila. For cervical and apical deviations, accuracy was preponderantly lower in maxilla. Despite the similar deviations measurement approaches described, clinical relevance of this study may be useful to warn the surgeon that safety margins in clinical situations. PMID:29657542
Not a Copernican observer: biased peculiar velocity statistics in the local Universe
NASA Astrophysics Data System (ADS)
Hellwing, Wojciech A.; Nusser, Adi; Feix, Martin; Bilicki, Maciej
2017-05-01
We assess the effect of the local large-scale structure on the estimation of two-point statistics of the observed radial peculiar velocities of galaxies. A large N-body simulation is used to examine these statistics from the perspective of random observers as well as 'Local Group-like' observers conditioned to reside in an environment resembling the observed Universe within 20 Mpc. The local environment systematically distorts the shape and amplitude of velocity statistics with respect to ensemble-averaged measurements made by a Copernican (random) observer. The Virgo cluster has the most significant impact, introducing large systematic deviations in all the statistics. For a simple 'top-hat' selection function, an idealized survey extending to ˜160 h-1 Mpc or deeper is needed to completely mitigate the effects of the local environment. Using shallower catalogues leads to systematic deviations of the order of 50-200 per cent depending on the scale considered. For a flat redshift distribution similar to the one of the CosmicFlows-3 survey, the deviations are even more prominent in both the shape and amplitude at all separations considered (≲100 h-1 Mpc). Conclusions based on statistics calculated without taking into account the impact of the local environment should be revisited.
Transport Coefficients from Large Deviation Functions
NASA Astrophysics Data System (ADS)
Gao, Chloe; Limmer, David
2017-10-01
We describe a method for computing transport coefficients from the direct evaluation of large deviation function. This method is general, relying on only equilibrium fluctuations, and is statistically efficient, employing trajectory based importance sampling. Equilibrium fluctuations of molecular currents are characterized by their large deviation functions, which is a scaled cumulant generating function analogous to the free energy. A diffusion Monte Carlo algorithm is used to evaluate the large deviation functions, from which arbitrary transport coefficients are derivable. We find significant statistical improvement over traditional Green-Kubo based calculations. The systematic and statistical errors of this method are analyzed in the context of specific transport coefficient calculations, including the shear viscosity, interfacial friction coefficient, and thermal conductivity.
Further evidence for cosmological evolution of the fine structure constant.
Webb, J K; Murphy, M T; Flambaum, V V; Dzuba, V A; Barrow, J D; Churchill, C W; Prochaska, J X; Wolfe, A M
2001-08-27
We describe the results of a search for time variability of the fine structure constant alpha using absorption systems in the spectra of distant quasars. Three large optical data sets and two 21 cm and mm absorption systems provide four independent samples, spanning approximately 23% to 87% of the age of the universe. Each sample yields a smaller alpha in the past and the optical sample shows a 4 sigma deviation: Delta alpha/alpha = -0.72+/-0.18 x 10(-5) over the redshift range 0.5
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giri, U; Ganesh, T; Saini, V
2016-06-15
Purpose: To quantify inherent uncertainty associated with a volumetric imaging system in its determination of positional shifts. Methods: The study was performed on an Elekta Axesse™ linac’s XVI cone beam computed tomography (CBCT) system. A CT image data set of a Penta- Guide phantom was used as reference image by placing isocenter at the center of the phantom.The phantom was placed arbitrarily on the couch close to isocenter and CBCT images were obtained. The CBCT dataset was matched with the reference image using XVI software and the shifts were determined in 6-dimensions. Without moving the phantom, this process was repeatedmore » 20 times consecutively within 30 minutes on a single day. Mean shifts and their standard deviations in all 6-dimensions were determined for all the 20 instances of imaging. For any given day, the first set of shifts obtained was kept as reference and the deviations of the subsequent 19 sets from the reference set were scored. Mean differences and their standard deviations were determined. In this way, data were obtained for 30 consecutive working days. Results: Tabulating the mean deviations and their standard deviations observed on each day for the 30 measurement days, systematic and random errors in the determination of shifts by XVI software were calculated. The systematic errors were found to be 0.03, 0.04 and 0.03 mm while random errors were 0.05, 0.06 and 0.06 mm in lateral, craniocaudal and anterio-posterior directions respectively. For rotational shifts, the systematic errors were 0.02°, 0.03° and 0.03° and random errors were 0.06°, 0.05° and 0.05° in pitch, roll and yaw directions respectively. Conclusion: The inherent uncertainties in every image guidance system should be assessed and baseline values established at the time of its commissioning. These shall be periodically tested as part of the QA protocol.« less
Autogenic training for stress and anxiety: a systematic review.
Ernst, E; Kanji, N
2000-06-01
The aim of this systematic review was to evaluate all controlled trials of autogenic training (AT) as a means of reducing stress and anxiety levels in human subjects. A search for all published and unpublished controlled trials was carried out in the four major databases, specifically CISCOM, Medline, PsychLit and CINAHL. Eight such trials were located, all of which are included here. The majority of trials were methodologically flawed. A range of outcome measures were used, with Spielberger's State-Trait Anxiety Inventory being the most popular. Deviations from the accepted technique of AT were conspicuous and trials using the classical AT were in the minority. Seven trials reported positive effects of AT in reducing stress. One study showed no such benefit. Since one trial had used AT in combination with another technique, visual imagery, no conclusion can be drawn about the effect of AT in this case. No firm conclusions could be drawn from this systematic review. AT, properly applied, remains to be tested in controlled trials that are appropriately planned and executed.
Numerical Investigations of Slip Phenomena in Centrifugal Compressor Impellers
NASA Astrophysics Data System (ADS)
Huang, Jeng-Min; Luo, Kai-Wei; Chen, Ching-Fu; Chiang, Chung-Ping; Wu, Teng-Yuan; Chen, Chun-Han
2013-03-01
This study systematically investigates the slip phenomena in the centrifugal air compressor impellers by CFD. Eight impeller blades for different specific speeds, wrap angles and exit blade angles are designed by compressor design software to analyze their flow fields. Except for the above three variables, flow rate and number of blades are the other two. Results show that the deviation angle decreases as the flow rate increases. The specific speed is not an important parameter regarding deviation angle or slip factor for general centrifugal compressor impellers. The slip onset position is closely related to the position of the peak value in the blade loading factor distribution. When no recirculation flow is present at the shroud, the variations of slip factor under various flow rates are mainly determined by difference between maximum blade angle and exit blade angle, Δβmax-2. The solidity should be of little importance to slip factor correlations in centrifugal compressor impellers.
A Flipped Pedagogy for Expert Problem Solving
NASA Astrophysics Data System (ADS)
Pritchard, David
The internet provides free learning opportunities for declarative (Wikipedia, YouTube) and procedural (Kahn Academy, MOOCs) knowledge, challenging colleges to provide learning at a higher cognitive level. Our ``Modeling Applied to Problem Solving'' pedagogy for Newtonian Mechanics imparts strategic knowledge - how to systematically determine which concepts to apply and why. Declarative and procedural knowledge is learned online before class via an e-text, checkpoint questions, and homework on edX.org (see http://relate.mit.edu/physicscourse); it is organized into five Core Models. Instructors then coach students on simple ``touchstone problems'', novel exercises, and multi-concept problems - meanwhile exercising three of the four C's: communication, collaboration, critical thinking and problem solving. Students showed 1.2 standard deviations improvement on the MIT final exam after three weeks instruction, a significant positive shift in 7 of the 9 categories in the CLASS, and their grades improved by 0.5 standard deviation in their following physics course (Electricity and Magnetism).
Impact of buildings on surface solar radiation over urban Beijing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Bin; Liou, Kuo-Nan; Gu, Yu
The rugged surface of an urban area due to varying buildings can interact with solar beams and affect both the magnitude and spatiotemporal distribution of surface solar fluxes. Here we systematically examine the impact of buildings on downward surface solar fluxes over urban Beijing by using a 3-D radiation parameterization that accounts for 3-D building structures vs. the conventional plane-parallel scheme. We find that the resulting downward surface solar flux deviations between the 3-D and the plane-parallel schemes are generally ±1–10 W m -2 at 800 m grid resolution and within ±1 W m -2 at 4 km resolution. Pairsmore » of positive–negative flux deviations on different sides of buildings are resolved at 800 m resolution, while they offset each other at 4 km resolution. Flux deviations from the unobstructed horizontal surface at 4 km resolution are positive around noon but negative in the early morning and late afternoon. The corresponding deviations at 800 m resolution, in contrast, show diurnal variations that are strongly dependent on the location of the grids relative to the buildings. Both the magnitude and spatiotemporal variations of flux deviations are largely dominated by the direct flux. Furthermore, we find that flux deviations can potentially be an order of magnitude larger by using a finer grid resolution. Atmospheric aerosols can reduce the magnitude of downward surface solar flux deviations by 10–65 %, while the surface albedo generally has a rather moderate impact on flux deviations. The results imply that the effect of buildings on downward surface solar fluxes may not be critically significant in mesoscale atmospheric models with a grid resolution of 4 km or coarser. However, the effect can play a crucial role in meso-urban atmospheric models as well as microscale urban dispersion models with resolutions of 1 m to 1 km.« less
Re-Os Systematics and HSE Distribution in Metal from Ochansk (H4) Chondrite
NASA Technical Reports Server (NTRS)
Smoliar, M. I.; Horan, M. F.; Alexander, C. M. OD.; Walker, R. J.
2003-01-01
Previous studies of the Re-Os systematics of chondrites have documented considerable variation in the Re/Os ratios of whole rock samples. For some whole rock chondrites, Re-Os systematics display large deviations from the primitive isochron that are considerably larger than deviations in other isotope systems. Possible interpretation of these facts is that the Re-Os system in chondrites is particularly sensitive to post-formation alteration processes, thus providing a useful tool to examine such processes. Significant variations that have been detected in highly siderophile element (HSE) patterns for ordinary chondrites support this conclusion. We report Re-Os isotope data for metal separates from the Ochansk H4 chondrite coupled with abundance data for Ru, Pd, Ir, and Pt, determined in the same samples by isotope dilution. We chose this meteorite mainly because it is an observed fall with minimal signs of weathering, and its low metamorphic grade (H4) and shock stage (S3).
Mass predictions of atomic nuclei in the infinite nuclear matter model
NASA Astrophysics Data System (ADS)
Nayak, R. C.; Satpathy, L.
2012-07-01
We present here the mass excesses, binding energies, one- and two-neutron, one- and two-proton and α-particle separation energies of 6727 nuclei in the ranges 4≤Z≤120 and 8≤A≤303 calculated in the infinite nuclear matter model. Compared to our predictions of 1999 mass table, the present ones are obtained using larger data base of 2003 mass table of Wapstra and Audi and resorting to higher accuracy in the solutions of the η-differential equations of the INM model. The local energy η's supposed to carry signature of the characteristic properties of nuclei are found to possess the predictive capability. In fact η-systematics reveal new magic numbers in the drip-line regions giving rise to new islands of stability supported by relativistic mean field theoretic calculations. This is a manifestation of a new phenomenon where shell-effect overcomes the instability due to repulsive components of the nucleon-nucleon force broadening the stability peninsula. The two-neutron separation energy-systematics derived from the present mass predictions reveal a general new feature for the existence of islands of inversion in the exotic neutron-rich regions of nuclear landscape, apart from supporting the presently known islands around 31Na and 62Ti. The five global parameters representing the properties of infinite nuclear matter, the surface, the Coulomb and the pairing terms are retained as per our 1999 mass table. The root-mean-square deviation of the present mass-fit to 2198 known masses is 342 keV, while the mean deviation is 1.3 keV, reminiscent of no left-over systematic effects. This is a substantive improvement over our 1999 mass table having rms deviation of 401 keV and mean deviation of 9 keV for 1884 data nuclei.
Setup and evaluation of a sensor tilting system for dimensional micro- and nanometrology
NASA Astrophysics Data System (ADS)
Schuler, Alexander; Weckenmann, Albert; Hausotte, Tino
2014-06-01
Sensors in micro- and nanometrology show their limits if the measurement objects and surfaces feature high aspect ratios, high curvature and steep surface angles. Their measurable surface angle is limited and an excess leads to measurement deviation and not detectable surface points. We demonstrate a principle to adapt the sensor's working angle during the measurement keeping the sensor in its optimal working angle. After the simulation of the principle, a hardware prototype was realized. It is based on a rotary kinematic chain with two rotary degrees of freedom, which extends the measurable surface angle to ±90° and is combined with a nanopositioning and nanomeasuring machine. By applying a calibration procedure with a quasi-tactile 3D sensor based on electrical near-field interaction the systematic position deviation of the kinematic chain is reduced. The paper shows for the first time the completed setup and integration of the prototype, the performance results of the calibration, the measurements with the prototype and the tilting principle, and finishes with the interpretation and feedback of the practical results.
Twining, Brian V.
2016-11-29
The U.S. Geological Survey (USGS), in cooperation with the U.S. Department of Energy, has maintained a water-level monitoring program at the Idaho National Laboratory (INL) since 1949. The purpose of the program is to systematically measure and report water-level data to assess the eastern Snake River Plain aquifer and long term changes in groundwater recharge, discharge, movement, and storage. Water-level data are commonly used to generate potentiometric maps and used to infer increases and (or) decreases in the regional groundwater system. Well deviation is one component of water-level data that is often overlooked and is the result of the well construction and the well not being plumb. Depending on measured slant angle, where well deviation generally increases linearly with increasing slant angle, well deviation can suggest artificial anomalies in the water table. To remove the effects of well deviation, the USGS INL Project Office applies a correction factor to water-level data when a well deviation survey indicates a change in the reference elevation of greater than or equal to 0.2 ft.Borehole well deviation survey data were considered for 177 wells completed within the eastern Snake River Plain aquifer, but not all wells had deviation survey data available. As of 2016, USGS INL Project Office database includes: 57 wells with gyroscopic survey data; 100 wells with magnetic deviation survey data; 11 wells with erroneous gyroscopic data that were excluded; and, 68 wells with no deviation survey data available. Of the 57 wells with gyroscopic deviation surveys, correction factors for 16 wells ranged from 0.20 to 6.07 ft and inclination angles (SANG) ranged from 1.6 to 16.0 degrees. Of the 100 wells with magnetic deviation surveys, a correction factor for 21 wells ranged from 0.20 to 5.78 ft and SANG ranged from 1.0 to 13.8 degrees, not including the wells that did not meet the correction factor criteria of greater than or equal to 0.20 ft.Forty-seven wells had gyroscopic and magnetic deviation survey data for the same well. Datasets for both survey types were compared for the same well to determine whether magnetic survey data were consistent with gyroscopic survey data. Of those 47 wells, 96 percent showed similar correction factor estimates (≤ 0.20 ft) for both magnetic and gyroscopic well deviation surveys. A linear comparison of correction factor estimates for both magnetic and gyroscopic deviation well surveys for all 47 wells indicate good linear correlation, represented by an r-squared of 0.88. The correction factor difference between the gyroscopic and magnetic surveys for 45 of 47 wells ranged from 0.00 to 0.18 ft, not including USGS 57 and USGS 125. Wells USGS 57 and USGS 125 show a correction factor difference of 2.16 and 0.36 ft, respectively; however, review of the data files suggest erroneous SANG data for both magnetic deviation well surveys. The difference in magnetic and gyroscopic well deviation SANG measurements, for all wells, ranged from 0.0 to 0.9 degrees. These data indicate good agreement between SANG data measured using the magnetic deviation survey methods and SANG data measured using gyroscopic deviation survey methods, even for surveys collected years apart.
Outcomes of deviation from treatment guidelines in status epilepticus: A systematic review.
Uppal, Preena; Cardamone, Michael; Lawson, John A
2018-04-16
Due to a gap between published clinical guidelines on status epilepticus SE and clinician management of SE, a systematic review was performed to investigate treatment adherence to SE guidelines and its impact on patient outcomes. Medline and Embase searches were conducted for studies appraising adherence to SE guidelines (from 1970 and 1st April 2018). The quality of eligible studies was assessed by QUADAS- 2 criteria. Comparison was made between patients where guidelines were followed and not followed. Various patient outcomes including intubation, ICU admission, morbidity and mortality were compared. A Forest plot was used to investigate the effect of adherence on outcome. A total of 3424 titles and abstracts were screened from the initial search after removal of duplicates. A total of 441 full text articles were reviewed in detail, and 22 articles were included in this study. The proportion of deviations ranged from 10.7% to 66.1%. Four studies were descriptive. Eighteen studies looked at the adverse effects of non-adherence. Eight studies showed respiratory depression and intubation were associated with excessive benzodiazepine use. A subset analysis showed 5.79 times higher odds of respiratory depression and intubation], if excessive benzodiazepines were given. The next most common variations were delayed management and insufficient treatment. These variations from the guidelines were associated with prolonged seizures. This review provides preliminary evidence that non-adherence to SE guidelines negatively impacts on patient outcomes. Appropriate and timely treatment is imperative for rapid seizure termination and improving outcomes. Copyright © 2018 British Epilepsy Association. All rights reserved.
Visch, Valentijn T; Tan, Ed S
2009-02-01
The reported study follows the footsteps of Heider, and Simmel (1944) [Heider, F., & Simmel, M. (1944). An experimental study of apparent behavior. American Journal of Psychology, 57, 243-249] and Michotte (1946/1963) [Michotte, A. (1963). The perception of causality (T.R. Miles & E. Miles, Trans.). London: Methuen (Original work published 1946)] who demonstrated the role of object movement in attributions of life-likeness to figures. It goes one step further in studying the categorization of film scenes as to genre as a function of object movements. In an animated film scene portraying a chase, movements of the chasing object were systematically varied as to parameters: velocity, efficiency, fluency, detail, and deformation. The object movements were categorized by viewers into genres: non-fiction, comedy, drama, and action. Besides this categorization, viewers rated their animacy attribution and emotional response. Results showed that non-expert viewers were consistent in categorizing the genres according to object movement parameters. The size of its deviation from the unmanipulated movement scene determined the assignment of any target scene to one of the fiction genres: small and moderate deviations resulted in categorization as drama and action, and large deviations as comedy. The results suggest that genre classification is achieved by, at least, three distinct cognitive processes: (a) animacy attribution, which influences the fiction versus non-fiction classification; (b) emotional responses, which influences the classification of a specific fiction genre; and (c) the amount of deviation from reality, at least with regard to movements.
Morkbak, Anne L; Heimdal, Randi M; Emmens, Kathleen; Molloy, Anne; Hvas, Anne-Mette; Schneede, Joern; Clarke, Robert; Scott, John M; Ueland, Per M; Nexo, Ebba
2005-01-01
A commercially available holotranscobalamin (holo-TC) radioimmunoassay (RIA) (Axis-Shield, Dundee, Scotland) was evaluated in four laboratories and compared with a holoTC ELISA run in one laboratory. The performance of the holoTC RIA assay was comparable in three of the four participating laboratories. The results from these three laboratories, involving at least 20 initial runs of "low", "medium" and "high" serum-based controls (mean holoTC concentrations 34, 60 and 110 pmol/L, respectively) yielded an intra-laboratory imprecision of 6-10%. No systematic inter-laboratory deviations were observed on runs involving 72 patient samples (holoTC concentration range 10-160 pmol/L). A fourth laboratory demonstrated higher assay imprecision for control samples and systematic deviation of results for the patient samples. Measurement of holoTC by ELISA showed an imprecision of 4-5%, and slightly higher mean values for the controls (mean holoTC concentrations 40, 70 and 114 pmol/L, respectively). Comparable results were obtained for the patient samples. The long-term intra-laboratory imprecision was 12% for the holoTC RIA and 6% for the ELISA. In conclusion, it would be prudent to check the calibration and precision prior to starting to use these holoTC assays in research or clinical practice. The results obtained using the holoTC RIA were similar to those obtained using the holoTC ELISA assay.
Mock, U; Dieckmann, K; Wolff, U; Knocke, T H; Pötter, R
1999-08-01
Geometrical accuracy in patient positioning can vary substantially during external radiotherapy. This study estimated the set-up accuracy during pelvic irradiation for gynecological malignancies for determination of safety margins (planning target volume, PTV). Based on electronic portal imaging devices (EPID), 25 patients undergoing 4-field pelvic irradiation for gynecological malignancies were analyzed with regard to set-up accuracy during the treatment course. Regularly performed EPID images were used in order to systematically assess the systematic and random component of set-up displacements. Anatomical matching of verification and simulation images was followed by measuring corresponding distances between the central axis and anatomical features. Data analysis of set-up errors referred to the x-, y-,and z-axes. Additionally, cumulative frequencies were evaluated. A total of 50 simulation films and 313 verification images were analyzed. For the anterior-posterior (AP) beam direction mean deviations along the x- and z-axes were 1.5 mm and -1.9 mm, respectively. Moreover, random errors of 4.8 mm (x-axis) and 3.0 mm (z-axis) were determined. Concerning the latero-lateral treatment fields, the systematic errors along the two axes were calculated to 2.9 mm (y-axis) and -2.0 mm (z-axis) and random errors of 3.8 mm and 3.5 mm were found, respectively. The cumulative frequency of misalignments < or =5 mm showed values of 75% (AP fields) and 72% (latero-lateral fields). With regard to cumulative frequencies < or =10 mm quantification revealed values of 97% for both beam directions. During external pelvic irradiation therapy for gynecological malignancies, EPID images on a regular basis revealed acceptable set-up inaccuracies. Safety margins (PTV) of 1 cm appear to be sufficient, accounting for more than 95% of all deviations.
NASA Astrophysics Data System (ADS)
Xu, Chong-yu; Tunemar, Liselotte; Chen, Yongqin David; Singh, V. P.
2006-06-01
Sensitivity of hydrological models to input data errors have been reported in the literature for particular models on a single or a few catchments. A more important issue, i.e. how model's response to input data error changes as the catchment conditions change has not been addressed previously. This study investigates the seasonal and spatial effects of precipitation data errors on the performance of conceptual hydrological models. For this study, a monthly conceptual water balance model, NOPEX-6, was applied to 26 catchments in the Mälaren basin in Central Sweden. Both systematic and random errors were considered. For the systematic errors, 5-15% of mean monthly precipitation values were added to the original precipitation to form the corrupted input scenarios. Random values were generated by Monte Carlo simulation and were assumed to be (1) independent between months, and (2) distributed according to a Gaussian law of zero mean and constant standard deviation that were taken as 5, 10, 15, 20, and 25% of the mean monthly standard deviation of precipitation. The results show that the response of the model parameters and model performance depends, among others, on the type of the error, the magnitude of the error, physical characteristics of the catchment, and the season of the year. In particular, the model appears less sensitive to the random error than to the systematic error. The catchments with smaller values of runoff coefficients were more influenced by input data errors than were the catchments with higher values. Dry months were more sensitive to precipitation errors than were wet months. Recalibration of the model with erroneous data compensated in part for the data errors by altering the model parameters.
Wehner, Rüdiger; Müller, Martin
2006-08-15
As textbook knowledge has it, bees and ants use polarized skylight as a backup cue whenever the main compass cue, the sun, is obscured by clouds. Here we show, by employing a unique experimental paradigm, that the celestial compass system of desert ants, Cataglyphis, relies predominantly on polarized skylight. If ants experience only parts of the polarization pattern during training but the full pattern in a subsequent test situation, they systematically deviate from their true homeward courses, with the systematics depending on what parts of the skylight patterns have been presented during training. This "signature" of the polarization compass remains unaltered, even if the ants can simultaneously experience the sun, which, if presented alone, enables the ants to select their true homeward courses. Information provided by direct sunlight and polarized skylight is picked up by different parts of the ant's compound eyes and is channeled into two rather separate systems of navigation.
Food price seasonality in Africa: Measurement and extent.
Gilbert, Christopher L; Christiaensen, Luc; Kaminski, Jonathan
2017-02-01
Everyone knows about seasonality. But what exactly do we know? This study systematically measures seasonal price gaps at 193 markets for 13 food commodities in seven African countries. It shows that the commonly used dummy variable or moving average deviation methods to estimate the seasonal gap can yield substantial upward bias. This can be partially circumvented using trigonometric and sawtooth models, which are more parsimonious. Among staple crops, seasonality is highest for maize (33 percent on average) and lowest for rice (16½ percent). This is two and a half to three times larger than in the international reference markets. Seasonality varies substantially across market places but maize is the only crop in which there are important systematic country effects. Malawi, where maize is the main staple, emerges as exhibiting the most acute seasonal differences. Reaching the Sustainable Development Goal of Zero Hunger requires renewed policy attention to seasonality in food prices and consumption.
Free Dendritic Growth of Succinonitrile-Acetone Alloys with Thermosolutal Melt Convection
NASA Technical Reports Server (NTRS)
Beckermann, Christoph; Li, Ben Q.
2003-01-01
A stagnant film model of the effects of thermosolutal convection on free dendritic growth of alloys is developed, and its predictions are compared to available earth-based experimental data for succinonitrileacetone alloys. It is found that the convection model gives excellent agreement with the measured dendrite tip velocities and radii for low solute concentrations. However, at higher solute concentrations the present predictions show some deviations from the measured data, and the measured (thermal) Peclet numbers tend to fall even below the predictions from diffusion theory. Furthermore, the measured selection parameter (sigma*) is significantly above the expected value of 0.02 and exhibits strong scatter. It is shown that convection is not responsible for these discrepancies. Some of the deviations between the predicted and measured data at higher supercoolings could be caused by measurement difficulties. The systematic disagreement in the selection parameter for higher solute concentrations and all supercoolings examined, indicates that the theory for the selection of the dendrite tip operating state in alloys may need to be reexamined.
Van Vugt, Floris Tijmen; Jabusch, Hans-Christian; Altenmüller, Eckart
2013-01-01
Whatever we do, we do it in our own way, and we recognize master artists by small samples of their work. This study investigates individuality of temporal deviations in musical scales in pianists in the absence of deliberate expressive intention. Note-by-note timing deviations away from regularity form a remarkably consistent “pianistic fingerprint.” First, eight professional pianists played C-major scales in two sessions, separated by 15 min. Euclidian distances between deviation traces originating from different pianists were reliably larger than traces originating from the same pianist. As a result, a simple classifier that matched deviation traces by minimizing their distance was able to recognize each pianist with 100% accuracy. Furthermore, within each pianist, fingerprints produced by the same movements were more similar than fingerprints resulting in the same scale sound. This allowed us to conclude that the fingerprints are mostly neuromuscular rather than intentional or expressive in nature. However, human listeners were not able to distinguish the temporal fingerprints by ear. Next, 18 pianists played C-major scales on a normal or muted piano. Recognition rates ranged from 83 to 100%, further supporting the view that auditory feedback is not implicated in the creation of the temporal signature. Finally, 20 pianists were recognized 20 months later at above chance level, showing signature effects to be long lasting. Our results indicate that even non-expressive playing of scales reveals consistent, partially effector-unspecific, but inaudible inter-individual differences. We suggest that machine learning studies into individuality in performance will need to take into account unintentional but consistent variability below the perceptual threshold. PMID:23519688
A neurophysiological explanation for biases in visual localization.
Moreland, James C; Boynton, Geoffrey M
2017-02-01
Observers show small but systematic deviations from equal weighting of all elements when asked to localize the center of an array of dots. Counter-intuitively, with small numbers of dots drawn from a Gaussian distribution, this bias results in subjects overweighting the influence of outlier dots - inconsistent with traditional statistical estimators of central tendency. Here we show that this apparent statistical anomaly can be explained by the observation that outlier dots also lie in regions of lower dot density. Using a standard model of V1 processing, which includes spatial integration followed by a compressive static nonlinearity, we can successfully predict the finding that dots in less dense regions of an array have a relatively greater influence on the perceived center.
Mass predictions of atomic nuclei in the infinite nuclear matter model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nayak, R.C., E-mail: rcnayak00@yahoo.com; Satpathy, L., E-mail: satpathy@iopb.res.in
We present here the mass excesses, binding energies, one- and two-neutron, one- and two-proton and {alpha}-particle separation energies of 6727 nuclei in the ranges 4{<=}Z{<=}120 and 8{<=}A{<=}303 calculated in the infinite nuclear matter model. Compared to our predictions of 1999 mass table, the present ones are obtained using larger data base of 2003 mass table of Wapstra and Audi and resorting to higher accuracy in the solutions of the {eta}-differential equations of the INM model. The local energy {eta}'s supposed to carry signature of the characteristic properties of nuclei are found to possess the predictive capability. In fact {eta}-systematics revealmore » new magic numbers in the drip-line regions giving rise to new islands of stability supported by relativistic mean field theoretic calculations. This is a manifestation of a new phenomenon where shell-effect overcomes the instability due to repulsive components of the nucleon-nucleon force broadening the stability peninsula. The two-neutron separation energy-systematics derived from the present mass predictions reveal a general new feature for the existence of islands of inversion in the exotic neutron-rich regions of nuclear landscape, apart from supporting the presently known islands around {sup 31}Na and {sup 62}Ti. The five global parameters representing the properties of infinite nuclear matter, the surface, the Coulomb and the pairing terms are retained as per our 1999 mass table. The root-mean-square deviation of the present mass-fit to 2198 known masses is 342 keV, while the mean deviation is 1.3 keV, reminiscent of no left-over systematic effects. This is a substantive improvement over our 1999 mass table having rms deviation of 401 keV and mean deviation of 9 keV for 1884 data nuclei.« less
Empirical Corrections to Nutation Amplitudes and Precession Computed from a Global VLBI Solution
NASA Astrophysics Data System (ADS)
Schuh, H.; Ferrandiz, J. M.; Belda-Palazón, S.; Heinkelmann, R.; Karbon, M.; Nilsson, T.
2017-12-01
The IAU2000A nutation and IAU2006 precession models were adopted to provide accurate estimations and predictions of the Celestial Intermediate Pole (CIP). However, they are not fully accurate and VLBI (Very Long Baseline Interferometry) observations show that the CIP deviates from the position resulting from the application of the IAU2006/2000A model. Currently, those deviations or offsets of the CIP (Celestial Pole Offsets - CPO), can only be obtained by the VLBI technique. The accuracy of the order of 0.1 milliseconds of arc (mas) allows to compare the observed nutation with theoretical prediction model for a rigid Earth and constrain geophysical parameters describing the Earth's interior. In this study, we empirically evaluate the consistency, systematics and deviations of the IAU 2006/2000A precession-nutation model using several CPO time series derived from the global analysis of VLBI sessions. The final objective is the reassessment of the precession offset and rate, and the amplitudes of the principal terms of nutation, trying to empirically improve the conventional values derived from the precession/nutation theories. The statistical analysis of the residuals after re-fitting the main nutation terms demonstrates that our empirical corrections attain an error reduction by almost 15 micro arc seconds.
High Frequency Fluctuations of Polar Motion During IGS'92 Campaign
NASA Astrophysics Data System (ADS)
Huang, Chengli; Jin, Wenjin; Liao, Dechun; Zhu, Wenyao; Wang, Jiexian
1994-09-01
During IGS'92 Campaign seven PM(Polar Motion) series provided by GPS Processing Centers are analysed in this paper. Some similar high frequency fluctuations in these PM series are detected by using spectra! analyses, least square adjustment and F-test as follows: there are short periodic fluctuations of 27.0, 16.5, 13.4, 10.4 day in X direction; and of 10.0, 20.5, 15.8 day in Y direction. And there are similar systematic deviations derived from the comparison of each series with EOP(IERS) 92 C 04. The inain cause of these systematic deviations is that the rotation between the reference frames of these series and ITRF91 exists. As for the reason, the coordinates of stations are not fixed (or partly fixed only) when solving X and Y with GPS data. The high frequency fluctuations of polar motion are explained to some extent by the excitation of atmospheric angular momentum.
Wu, Tzi-Yi; Chen, Bor-Kuan; Hao, Lin; Peng, Yu-Chun; Sun, I-Wen
2011-01-01
A systematic study of the effect of composition on the thermo-physical properties of the binary mixtures of 1-methyl-3-pentyl imidazolium hexafluorophosphate [MPI][PF6] with poly(ethylene glycol) (PEG) [Mw = 400] is presented. The excess molar volume, refractive index deviation, viscosity deviation, and surface tension deviation values were calculated from these experimental density, ρ, refractive index, n, viscosity, η, and surface tension, γ, over the whole concentration range, respectively. The excess molar volumes are negative and continue to become increasingly negative with increasing temperature; whereas the viscosity and surface tension deviation are negative and become less negative with increasing temperature. The surface thermodynamic functions, such as surface entropy, enthalpy, as well as standard molar entropy, Parachor, and molar enthalpy of vaporization for pure ionic liquid, have been derived from the temperature dependence of the surface tension values. PMID:21731460
Visual space under free viewing conditions.
Doumen, Michelle J A; Kappers, Astrid M L; Koenderink, Jan J
2005-10-01
Most research on visual space has been done under restricted viewing conditions and in reduced environments. In our experiments, observers performed an exocentric pointing task, a collinearity task, and a parallelity task in a entirely visible room. We varied the relative distances between the objects and the observer and the separation angle between the two objects. We were able to compare our data directly with data from experiments in an environment with less monocular depth information present. We expected that in a richer environment and under less restrictive viewing conditions, the settings would deviate less from the veridical settings. However, large systematic deviations from veridical settings were found for all three tasks. The structure of these deviations was task dependent, and the structure and the deviations themselves were comparable to those obtained under more restricted circumstances. Thus, the additional information was not used effectively by the observers.
NASA Astrophysics Data System (ADS)
Stier, P.; Schutgens, N. A. J.; Bian, H.; Boucher, O.; Chin, M.; Ghan, S.; Huneeus, N.; Kinne, S.; Lin, G.; Myhre, G.; Penner, J. E.; Randles, C.; Samset, B.; Schulz, M.; Yu, H.; Zhou, C.
2012-09-01
Simulated multi-model "diversity" in aerosol direct radiative forcing estimates is often perceived as measure of aerosol uncertainty. However, current models used for aerosol radiative forcing calculations vary considerably in model components relevant for forcing calculations and the associated "host-model uncertainties" are generally convoluted with the actual aerosol uncertainty. In this AeroCom Prescribed intercomparison study we systematically isolate and quantify host model uncertainties on aerosol forcing experiments through prescription of identical aerosol radiative properties in nine participating models. Even with prescribed aerosol radiative properties, simulated clear-sky and all-sky aerosol radiative forcings show significant diversity. For a purely scattering case with globally constant optical depth of 0.2, the global-mean all-sky top-of-atmosphere radiative forcing is -4.51 W m-2 and the inter-model standard deviation is 0.70 W m-2, corresponding to a relative standard deviation of 15%. For a case with partially absorbing aerosol with an aerosol optical depth of 0.2 and single scattering albedo of 0.8, the forcing changes to 1.26 W m-2, and the standard deviation increases to 1.21 W m-2, corresponding to a significant relative standard deviation of 96%. However, the top-of-atmosphere forcing variability owing to absorption is low, with relative standard deviations of 9% clear-sky and 12% all-sky. Scaling the forcing standard deviation for a purely scattering case to match the sulfate radiative forcing in the AeroCom Direct Effect experiment, demonstrates that host model uncertainties could explain about half of the overall sulfate forcing diversity of 0.13 W m-2 in the AeroCom Direct Radiative Effect experiment. Host model errors in aerosol radiative forcing are largest in regions of uncertain host model components, such as stratocumulus cloud decks or areas with poorly constrained surface albedos, such as sea ice. Our results demonstrate that host model uncertainties are an important component of aerosol forcing uncertainty that require further attention.
Ettlinger, Andreas; Neuner, Hans; Burgess, Thomas
2018-01-01
The topic of indoor positioning and indoor navigation by using observations from smartphone sensors is very challenging as the determined trajectories can be subject to significant deviations compared to the route travelled in reality. Especially the calculation of the direction of movement is the critical part of pedestrian positioning approaches such as Pedestrian Dead Reckoning (“PDR”). Due to distinct systematic effects in filtered trajectories, it can be assumed that there are systematic deviations present in the observations from smartphone sensors. This article has two aims: one is to enable the estimation of partial redundancies for each observation as well as for observation groups. Partial redundancies are a measure for the reliability indicating how well systematic deviations can be detected in single observations used in PDR. The second aim is to analyze the behavior of partial redundancy by modifying the stochastic and functional model of the Kalman filter. The equations relating the observations to the orientation are condition equations, which do not exhibit the typical structure of the Gauss-Markov model (“GMM”), wherein the observations are linear and can be formulated as functions of the states. To calculate and analyze the partial redundancy of the observations from smartphone-sensors used in PDR, the system equation and the measurement equation of a Kalman filter as well as the redundancy matrix need to be derived in the Gauss-Helmert model (“GHM”). These derivations are introduced in this article and lead to a novel Kalman filter structure based on condition equations, enabling reliability assessment of each observation. PMID:29385076
Ettlinger, Andreas; Neuner, Hans; Burgess, Thomas
2018-01-31
The topic of indoor positioning and indoor navigation by using observations from smartphone sensors is very challenging as the determined trajectories can be subject to significant deviations compared to the route travelled in reality. Especially the calculation of the direction of movement is the critical part of pedestrian positioning approaches such as Pedestrian Dead Reckoning ("PDR"). Due to distinct systematic effects in filtered trajectories, it can be assumed that there are systematic deviations present in the observations from smartphone sensors. This article has two aims: one is to enable the estimation of partial redundancies for each observation as well as for observation groups. Partial redundancies are a measure for the reliability indicating how well systematic deviations can be detected in single observations used in PDR. The second aim is to analyze the behavior of partial redundancy by modifying the stochastic and functional model of the Kalman filter. The equations relating the observations to the orientation are condition equations, which do not exhibit the typical structure of the Gauss-Markov model ("GMM"), wherein the observations are linear and can be formulated as functions of the states. To calculate and analyze the partial redundancy of the observations from smartphone-sensors used in PDR, the system equation and the measurement equation of a Kalman filter as well as the redundancy matrix need to be derived in the Gauss-Helmert model ("GHM"). These derivations are introduced in this article and lead to a novel Kalman filter structure based on condition equations, enabling reliability assessment of each observation.
NASA Astrophysics Data System (ADS)
Claret, A.; Willems, B.
2002-06-01
We revised the current status of the apsidal-motion test to stellar structure and evolution. The observational sample was increased by about 50% in comparison to previous studies. Classical and relativistic systems were analyzed simultaneously and only systems with accurate absolute dimensions were considered. New interior models incorporating recent opacity tables, stellar rotation, mass loss, and moderate core overshooting were used as theoretical tools to compare the predicted with the observed shifts of the position of the periastron. The stellar models were computed for the precise observed masses and the adopted chemical compositions are consistent with the corresponding tables of opacities to avoid the inherent problems of interpolation in mass and in (X, Z). The derived chemical composition for each individual system was used to infer the primordial helium content as well as a law of enrichment. The values found are in good agreement with those obtained from various independent sources. For the first time, the effects of dynamic tides are taken into account systematically to determine the contribution of the tidal distortion to the predicted apsidal-motion rate. The deviations between the apsidal-motion rates resulting from the classical formula and those determined by taking into account the effects of dynamic tides are presented as a function of the level of synchronism. For systems close to synchronisation, dynamic tides cause deviations with respect to the classical apsidal-motion formula due to the effects of the compressibility of the stellar fluid. For systems with higher rotational angular velocities, additional deviations due to resonances arise when the forcing frequencies of the dynamic tides come into the range of the free oscillation modes of the component stars. The resulting comparison shows a good agreement between the observed and theoretical apsidal-motion rates. No systematic effects in the sense that models are less mass concentrated than real stars and no correlations with the evolutionary status of the systems were detected.
Computational aspects of geometric correction data generation in the LANDSAT-D imagery processing
NASA Technical Reports Server (NTRS)
Levine, I.
1981-01-01
A method is presented for systematic and geodetic correction data calculation. It is based on presentation of image distortions as a sum of nominal distortions and linear effects caused by variation of the spacecraft position and attitude variables from their nominals. The method may be used for both MSS and TM image data and it is incorporated into the processing by means of mostly offline calculations. Modeling shows that the maximal of the method are of the order of 5m at the worst point in a frame; the standard deviations of the average errors less than .8m.
Measurement of prominent eta-decay branching fractions.
Lopez, A; Mehrabyan, S; Mendez, H; Ramirez, J; Ge, J Y; Miller, D H; Sanghi, B; Shipsey, I P J; Xin, B; Adams, G S; Anderson, M; Cummings, J P; Danko, I; Hu, D; Moziak, B; Napolitano, J; He, Q; Insler, J; Muramatsu, H; Park, C S; Thorndike, E H; Yang, F; Artuso, M; Blusk, S; Khalil, S; Li, J; Menaa, N; Mountain, R; Nisar, S; Randrianarivony, K; Sia, R; Skwarnicki, T; Stone, S; Wang, J C; Bonvicini, G; Cinabro, D; Dubrovin, M; Lincoln, A; Asner, D M; Edwards, K W; Naik, P; Briere, R A; Ferguson, T; Tatishvili, G; Vogel, H; Watkins, M E; Rosner, J L; Adam, N E; Alexander, J P; Cassel, D G; Duboscq, J E; Ehrlich, R; Fields, L; Galik, R S; Gibbons, L; Gray, R; Gray, S W; Hartill, D L; Heltsley, B K; Hertz, D; Jones, C D; Kandaswamy, J; Kreinick, D L; Kuznetsov, V E; Mahlke-Krüger, H; Mohapatra, D; Onyisi, P U E; Patterson, J R; Peterson, D; Riley, D; Ryd, A; Sadoff, A J; Shi, X; Stroiney, S; Sun, W M; Wilksen, T; Athar, S B; Patel, R; Yelton, J; Rubin, P; Eisenstein, B I; Karliner, I; Lowrey, N; Selen, M; White, E J; Wiss, J; Mitchell, R E; Shepherd, M R; Besson, D; Pedlar, T K; Cronin-Hennessy, D; Gao, K Y; Hietala, J; Kubota, Y; Klein, T; Lang, B W; Poling, R; Scott, A W; Zweber, P; Dobbs, S; Metreveli, Z; Seth, K K; Tomaradze, A; Ernst, J; Ecklund, K M; Severini, H; Love, W; Savinov, V
2007-09-21
The decay psi(2S) --> etaJ/psi is used to measure, for the first time, all prominent eta-meson branching fractions with the same experiment in the same dataset, thereby providing a consistent treatment of systematics across branching fractions. We present results for eta decays to gamma gamma, pi(+)pi(-)pi(0), 3pi(0), pi(+)pi(-)gamma and e(+)e(-)gamma, accounting for 99.9% of all eta decays. The precision of several of the branching fractions and their ratios is improved. Two channels, pi(+)pi(-)gamma and e(+)e(-)gamma, show results that differ at the level of three standard deviations from those previously determined.
Measurement of Prominent η-Decay Branching Fractions
NASA Astrophysics Data System (ADS)
Lopez, A.; Mehrabyan, S.; Mendez, H.; Ramirez, J.; Ge, J. Y.; Miller, D. H.; Sanghi, B.; Shipsey, I. P. J.; Xin, B.; Adams, G. S.; Anderson, M.; Cummings, J. P.; Danko, I.; Hu, D.; Moziak, B.; Napolitano, J.; He, Q.; Insler, J.; Muramatsu, H.; Park, C. S.; Thorndike, E. H.; Yang, F.; Artuso, M.; Blusk, S.; Khalil, S.; Li, J.; Menaa, N.; Mountain, R.; Nisar, S.; Randrianarivony, K.; Sia, R.; Skwarnicki, T.; Stone, S.; Wang, J. C.; Bonvicini, G.; Cinabro, D.; Dubrovin, M.; Lincoln, A.; Asner, D. M.; Edwards, K. W.; Naik, P.; Briere, R. A.; Ferguson, T.; Tatishvili, G.; Vogel, H.; Watkins, M. E.; Rosner, J. L.; Adam, N. E.; Alexander, J. P.; Cassel, D. G.; Duboscq, J. E.; Ehrlich, R.; Fields, L.; Galik, R. S.; Gibbons, L.; Gray, R.; Gray, S. W.; Hartill, D. L.; Heltsley, B. K.; Hertz, D.; Jones, C. D.; Kandaswamy, J.; Kreinick, D. L.; Kuznetsov, V. E.; Mahlke-Krüger, H.; Mohapatra, D.; Onyisi, P. U. E.; Patterson, J. R.; Peterson, D.; Riley, D.; Ryd, A.; Sadoff, A. J.; Shi, X.; Stroiney, S.; Sun, W. M.; Wilksen, T.; Athar, S. B.; Patel, R.; Yelton, J.; Rubin, P.; Eisenstein, B. I.; Karliner, I.; Lowrey, N.; Selen, M.; White, E. J.; Wiss, J.; Mitchell, R. E.; Shepherd, M. R.; Besson, D.; Pedlar, T. K.; Cronin-Hennessy, D.; Gao, K. Y.; Hietala, J.; Kubota, Y.; Klein, T.; Lang, B. W.; Poling, R.; Scott, A. W.; Zweber, P.; Dobbs, S.; Metreveli, Z.; Seth, K. K.; Tomaradze, A.; Ernst, J.; Ecklund, K. M.; Severini, H.; Love, W.; Savinov, V.
2007-09-01
The decay ψ(2S)→ηJ/ψ is used to measure, for the first time, all prominent η-meson branching fractions with the same experiment in the same dataset, thereby providing a consistent treatment of systematics across branching fractions. We present results for η decays to γγ, π+π-π0, 3π0, π+π-γ and e+e-γ, accounting for 99.9% of all η decays. The precision of several of the branching fractions and their ratios is improved. Two channels, π+π-γ and e+e-γ, show results that differ at the level of three standard deviations from those previously determined.
Surprisingly rational: probability theory plus noise explains biases in judgment.
Costello, Fintan; Watts, Paul
2014-07-01
The systematic biases seen in people's probability judgments are typically taken as evidence that people do not use the rules of probability theory when reasoning about probability but instead use heuristics, which sometimes yield reasonable judgments and sometimes yield systematic biases. This view has had a major impact in economics, law, medicine, and other fields; indeed, the idea that people cannot reason with probabilities has become a truism. We present a simple alternative to this view, where people reason about probability according to probability theory but are subject to random variation or noise in the reasoning process. In this account the effect of noise is canceled for some probabilistic expressions. Analyzing data from 2 experiments, we find that, for these expressions, people's probability judgments are strikingly close to those required by probability theory. For other expressions, this account produces systematic deviations in probability estimates. These deviations explain 4 reliable biases in human probabilistic reasoning (conservatism, subadditivity, conjunction, and disjunction fallacies). These results suggest that people's probability judgments embody the rules of probability theory and that biases in those judgments are due to the effects of random noise. (c) 2014 APA, all rights reserved.
Range and Energy Straggling in Ion Beam Transport
NASA Technical Reports Server (NTRS)
Wilson, John W.; Tai, Hsiang
2000-01-01
A first-order approximation to the range and energy straggling of ion beams is given as a normal distribution for which the standard deviation is estimated from the fluctuations in energy loss events. The standard deviation is calculated by assuming scattering from free electrons with a long range cutoff parameter that depends on the mean excitation energy of the medium. The present formalism is derived by extrapolating Payne's formalism to low energy by systematic energy scaling and to greater depths of penetration by a second-order perturbation. Limited comparisons are made with experimental data.
Couch height–based patient setup for abdominal radiation therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohira, Shingo; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita; Ueda, Yoshihiro
2016-04-01
There are 2 methods commonly used for patient positioning in the anterior-posterior (A-P) direction: one is the skin mark patient setup method (SMPS) and the other is the couch height–based patient setup method (CHPS). This study compared the setup accuracy of these 2 methods for abdominal radiation therapy. The enrollment for this study comprised 23 patients with pancreatic cancer. For treatments (539 sessions), patients were set up by using isocenter skin marks and thereafter treatment couch was shifted so that the distance between the isocenter and the upper side of the treatment couch was equal to that indicated on themore » computed tomographic (CT) image. Setup deviation in the A-P direction for CHPS was measured by matching the spine of the digitally reconstructed radiograph (DRR) of a lateral beam at simulation with that of the corresponding time-integrated electronic portal image. For SMPS with no correction (SMPS/NC), setup deviation was calculated based on the couch-level difference between SMPS and CHPS. SMPS/NC was corrected using 2 off-line correction protocols: no action level (SMPS/NAL) and extended NAL (SMPS/eNAL) protocols. Margins to compensate for deviations were calculated using the Stroom formula. A-P deviation > 5 mm was observed in 17% of SMPS/NC, 4% of SMPS/NAL, and 4% of SMPS/eNAL sessions but only in one CHPS session. For SMPS/NC, 7 patients (30%) showed deviations at an increasing rate of > 0.1 mm/fraction, but for CHPS, no such trend was observed. The standard deviations (SDs) of systematic error (Σ) were 2.6, 1.4, 0.6, and 0.8 mm and the root mean squares of random error (σ) were 2.1, 2.6, 2.7, and 0.9 mm for SMPS/NC, SMPS/NAL, SMPS/eNAL, and CHPS, respectively. Margins to compensate for the deviations were wide for SMPS/NC (6.7 mm), smaller for SMPS/NAL (4.6 mm) and SMPS/eNAL (3.1 mm), and smallest for CHPS (2.2 mm). Achieving better setup with smaller margins, CHPS appears to be a reproducible method for abdominal patient setup.« less
When things go pear shaped: contour variations of contacts
NASA Astrophysics Data System (ADS)
Utzny, Clemens
2013-04-01
Traditional control of critical dimensions (CD) on photolithographic masks considers the CD average and a measure for the CD variation such as the CD range or the standard deviation. Also systematic CD deviations from the mean such as CD signatures are subject to the control. These measures are valid for mask quality verification as long as patterns across a mask exhibit only size variations and no shape variation. The issue of shape variations becomes especially important in the context of contact holes on EUV masks. For EUV masks the CD error budget is much smaller than for standard optical masks. This means that small deviations from the contact shape can impact EUV waver prints in the sense that contact shape deformations induce asymmetric bridging phenomena. In this paper we present a detailed study of contact shape variations based on regular product data. Two data sets are analyzed: 1) contacts of varying target size and 2) a regularly spaced field of contacts. Here, the methods of statistical shape analysis are used to analyze CD SEM generated contour data. We demonstrate that contacts on photolithographic masks do not only show size variations but exhibit also pronounced nontrivial shape variations. In our data sets we find pronounced shape variations which can be interpreted as asymmetrical shape squeezing and contact rounding. Thus we demonstrate the limitations of classic CD measures for describing the feature variations on masks. Furthermore we show how the methods of statistical shape analysis can be used for quantifying the contour variations thus paving the way to a new understanding of mask linearity and its specification.
Basic life support: evaluation of learning using simulation and immediate feedback devices1.
Tobase, Lucia; Peres, Heloisa Helena Ciqueto; Tomazini, Edenir Aparecida Sartorelli; Teodoro, Simone Valentim; Ramos, Meire Bruna; Polastri, Thatiane Facholi
2017-10-30
to evaluate students' learning in an online course on basic life support with immediate feedback devices, during a simulation of care during cardiorespiratory arrest. a quasi-experimental study, using a before-and-after design. An online course on basic life support was developed and administered to participants, as an educational intervention. Theoretical learning was evaluated by means of a pre- and post-test and, to verify the practice, simulation with immediate feedback devices was used. there were 62 participants, 87% female, 90% in the first and second year of college, with a mean age of 21.47 (standard deviation 2.39). With a 95% confidence level, the mean scores in the pre-test were 6.4 (standard deviation 1.61), and 9.3 in the post-test (standard deviation 0.82, p <0.001); in practice, 9.1 (standard deviation 0.95) with performance equivalent to basic cardiopulmonary resuscitation, according to the feedback device; 43.7 (standard deviation 26.86) mean duration of the compression cycle by second of 20.5 (standard deviation 9.47); number of compressions 167.2 (standard deviation 57.06); depth of compressions of 48.1 millimeter (standard deviation 10.49); volume of ventilation 742.7 (standard deviation 301.12); flow fraction percentage of 40.3 (standard deviation 10.03). the online course contributed to learning of basic life support. In view of the need for technological innovations in teaching and systematization of cardiopulmonary resuscitation, simulation and feedback devices are resources that favor learning and performance awareness in performing the maneuvers.
A simple method to relate microwave radiances to upper tropospheric humidity
NASA Astrophysics Data System (ADS)
Buehler, S. A.; John, V. O.
2005-01-01
A brightness temperature (BT) transformation method can be applied to microwave data to retrieve Jacobian weighted upper tropospheric relative humidity (UTH) in a broad layer centered roughly between 6 and 8 km altitude. The UTH bias is below 4% RH, and the relative UTH bias below 20%. The UTH standard deviation is between 2 and 6.5% RH in absolute numbers, or between 10 and 27% in relative numbers. The standard deviation is dominated by the regression noise, resulting from vertical structure not accounted for by the simple transformation relation. The UTH standard deviation due to radiometric noise alone has a relative standard deviation of approximately 7% for a radiometric noise level of 1 K. The retrieval performance was shown to be of almost constant quality for all viewing angles and latitudes, except for problems at high latitudes due to surface effects. A validation of AMSU UTH against radiosonde UTH shows reasonable agreement if known systematic differences between AMSU and radiosonde are taken into account. When the method is applied to supersaturation studies, regression noise and radiometric noise could lead to an apparent supersaturation even if there were no supersaturation. For a radiometer noise level of 1 K the drop-off slope of the apparent supersaturation is 0.17% RH-1, for a noise level of 2 K the slope is 0.12% RH-1. The main conclusion from this study is that the BT transformation method is very well suited for microwave data. Its particular strength is in climatological applications where the simplicity and the a priori independence are key advantages.
NASA Astrophysics Data System (ADS)
Zhao, Kui; Lv, Bing; Deng, Liangzi; Xue, Yuyi; Chu, Paul; High pressure low temperature lab Team
2014-03-01
Extensive studies have been carried out on the induction of bulk superconductivity in the Fe-pnictide 122 system with a Tc up to 38 K through doping and/or pressure. However, non-bulk superconductivity has also been detected unexpectedly in undoped AFe2As2 where A = Ca, Sr, and Ba with Tc = ~12K, ~22K and ~23K, respectively. The reason for the observation remains unknown. Recently, systematic investigation shows that highly anisotropic superconductivity with a Tc up to 49 K and superparamagnetism occur in rare-earth doped Ca122. Further examination reveals slight deviation from the 1:2:2 stoichiometry which correlates closely with the occurrence of non-bulk superconductivity and superparamagnetism in these samples. We have therefore decided to investigate systematically the stoichiometry, defects, magnetism and superconductivity in undoped AFe2As2 single crystals under different synthesis conditions where A = Ca, Sr, and Ba. Results will be presented and discussed.
Wehner, Rüdiger; Müller, Martin
2006-01-01
As textbook knowledge has it, bees and ants use polarized skylight as a backup cue whenever the main compass cue, the sun, is obscured by clouds. Here we show, by employing a unique experimental paradigm, that the celestial compass system of desert ants, Cataglyphis, relies predominantly on polarized skylight. If ants experience only parts of the polarization pattern during training but the full pattern in a subsequent test situation, they systematically deviate from their true homeward courses, with the systematics depending on what parts of the skylight patterns have been presented during training. This “signature” of the polarization compass remains unaltered, even if the ants can simultaneously experience the sun, which, if presented alone, enables the ants to select their true homeward courses. Information provided by direct sunlight and polarized skylight is picked up by different parts of the ant’s compound eyes and is channeled into two rather separate systems of navigation. PMID:16888039
Hardman, John; Al-Hadithy, Nawfal; Hester, Thomas; Anakwe, Raymond
2015-12-01
There remains little consensus regarding the optimal management of distal radius fractures. Fixed angle volar devices have gained recent popularity, but have also been associated with soft tissue complications. Intramedullary (IM) devices offer fixed angle stabilisation with minimally invasive surgical technique and low, IM profile. No formal review of outcomes could be identified. We conducted a systematic review of clinical studies regarding the use of fixed angle IM devices in acute extra-articular or simple intra-articular distal radius fractures. Preferred Reporting Items for Systematic Reviews (PRISMA) guidance was followed. Numerical data regarding functional scores, ranges of movement, radiological outcomes and complications were pooled to produce aggregate means and standard deviation. A total of 310 titles and abstracts were identified. Fourteen papers remained for analysis. Total patient number was 357, mean age 63.72 years and mean follow-up 12.77 months. Mean functional scores were all rated as 'excellent'. Aggregate means: flexion 53.62°, extension 56.38°, pronation 69.10°, supination 70.29°, ulnar deviation 28.35°, radial deviation 18.12°, radial height 8.98 mm, radial inclination 16.51°, volar tilt 5.35°, ulnar variance 0.66 mm and grip strength 90.37 %. Overall complication rate was 19.6 %. Tendon rupture was unreported. Tendon irritation was 0.88 %. Radial nerve paraesthesia was 11.44 %. Fixed angle IM devices facilitate excellent functional outcomes, with radiological and clinical parameters at least equivalent to volar plate devices. Low rates of tendon irritation and absence of tendon rupture are advantageous. Significant limitations include a lack of application for complex articular injuries and the propensity to cause a transient neuritis of the superficial branch of the radial nerve.
The geomechanical strength of carbonate rock in Kinta valley, Ipoh, Perak Malaysia
NASA Astrophysics Data System (ADS)
Mazlan, Nur Amanina; Lai, Goh Thian; Razib, Ainul Mardhiyah Mohd; Rafek, Abdul Ghani; Serasa, Ailie Sofyiana; Simon, Norbert; Surip, Noraini; Ern, Lee Khai; Mohamed, Tuan Rusli
2018-04-01
The stability of both cut rocks and underground openings were influenced by the geomechanical strength of rock materials, while the strength characteristics are influenced by both material characteristics and the condition of weathering. This paper present a systematic approach to quantify the rock material strength characteristics for material failure and material & discontinuities failure by using uniaxial compressive strength, point load strength index and Brazilian tensile strength for carbonate rocks. Statistical analysis of the results at 95 percent confidence level showed that the mean value of compressive strength, point load strength index and Brazilian tensile strength for with material failure and material & discontinuities failure were 76.8 ± 4.5 and 41.2 ± 4.1 MPa with standard deviation of 15.2 and 6.5 MPa, respectively. The point load strength index for material failure and material & discontinuities failure were 3.1 ± 0.2 MPa and 1.8 ± 0.3 MPa with standard deviation of 0.9 and 0.6 MPa, respectively. The Brazilian tensile strength with material failure and material & discontinuities failure were 7.1 ± 0.3 MPa and 4.1 ± 0.3 MPa with standard deviation of 1.4 and 0.6 MPa, respectively. The results of this research revealed that the geomechanical strengths of rock material of carbonate rocks for material & discontinuities failure deteriorates approximately ½ from material failure.
Scaling relations in mountain streams: colluvial and Quaternary controls
NASA Astrophysics Data System (ADS)
Brardinoni, Francesco; Hassan, Marwan; Church, Michael
2010-05-01
In coastal British Columbia, Canada, the glacial palimpsest profoundly affects the geomorphic structure of mountain drainage basins. In this context, by combining remotely sensed, field- and GIS-based data, we examine the scaling behavior of bankfull width and depth with contributing area in a process-based framework. We propose a novel approach that, by detailing interactions between colluvial and fluvial processes, provides new insights on the geomorphic functioning of mountain channels. This approach evaluates the controls exerted by a parsimonious set of governing factors on channel size. Results indicate that systematic deviations from simple power-law trends in bankfull width and depth are common. Deviations are modulated by interactions between the inherited glacial and paraglacial topography (imposed slope), coarse grain-size fraction, and chiefly the rate of colluvial sediment delivery to streams. Cumulatively, departures produce distal cross-sections that are typically narrower and shallower than expected. These outcomes, while reinforcing the notion that mountain drainage basins in formerly glaciated systems are out of balance with current environmental conditions, show that cross-sectional scaling relations are useful metrics for understanding colluvial-alluvial interactions.
Regional infant brain development: an MRI-based morphometric analysis in 3 to 13 month olds.
Choe, Myong-Sun; Ortiz-Mantilla, Silvia; Makris, Nikos; Gregas, Matt; Bacic, Janine; Haehn, Daniel; Kennedy, David; Pienaar, Rudolph; Caviness, Verne S; Benasich, April A; Grant, P Ellen
2013-09-01
Elucidation of infant brain development is a critically important goal given the enduring impact of these early processes on various domains including later cognition and language. Although infants' whole-brain growth rates have long been available, regional growth rates have not been reported systematically. Accordingly, relatively less is known about the dynamics and organization of typically developing infant brains. Here we report global and regional volumetric growth of cerebrum, cerebellum, and brainstem with gender dimorphism, in 33 cross-sectional scans, over 3 to 13 months, using T1-weighted 3-dimensional spoiled gradient echo images and detailed semi-automated brain segmentation. Except for the midbrain and lateral ventricles, all absolute volumes of brain regions showed significant growth, with 6 different patterns of volumetric change. When normalized to the whole brain, the regional increase was characterized by 5 differential patterns. The putamen, cerebellar hemispheres, and total cerebellum were the only regions that showed positive growth in the normalized brain. Our results show region-specific patterns of volumetric change and contribute to the systematic understanding of infant brain development. This study greatly expands our knowledge of normal development and in future may provide a basis for identifying early deviation above and beyond normative variation that might signal higher risk for neurological disorders.
Regional Infant Brain Development: An MRI-Based Morphometric Analysis in 3 to 13 Month Olds
Choe, Myong-sun; Ortiz-Mantilla, Silvia; Makris, Nikos; Gregas, Matt; Bacic, Janine; Haehn, Daniel; Kennedy, David; Pienaar, Rudolph; Caviness, Verne S.; Benasich, April A.; Grant, P. Ellen
2013-01-01
Elucidation of infant brain development is a critically important goal given the enduring impact of these early processes on various domains including later cognition and language. Although infants’ whole-brain growth rates have long been available, regional growth rates have not been reported systematically. Accordingly, relatively less is known about the dynamics and organization of typically developing infant brains. Here we report global and regional volumetric growth of cerebrum, cerebellum, and brainstem with gender dimorphism, in 33 cross-sectional scans, over 3 to 13 months, using T1-weighted 3-dimensional spoiled gradient echo images and detailed semi-automated brain segmentation. Except for the midbrain and lateral ventricles, all absolute volumes of brain regions showed significant growth, with 6 different patterns of volumetric change. When normalized to the whole brain, the regional increase was characterized by 5 differential patterns. The putamen, cerebellar hemispheres, and total cerebellum were the only regions that showed positive growth in the normalized brain. Our results show region-specific patterns of volumetric change and contribute to the systematic understanding of infant brain development. This study greatly expands our knowledge of normal development and in future may provide a basis for identifying early deviation above and beyond normative variation that might signal higher risk for neurological disorders. PMID:22772652
Krimmel, R.M.
1999-01-01
Net mass balance has been measured since 1958 at South Cascade Glacier using the 'direct method,' e.g. area averages of snow gain and firn and ice loss at stakes. Analysis of cartographic vertical photography has allowed measurement of mass balance using the 'geodetic method' in 1970, 1975, 1977, 1979-80, and 1985-97. Water equivalent change as measured by these nearly independent methods should give similar results. During 1970-97, the direct method shows a cumulative balance of about -15 m, and the geodetic method shows a cumulative balance of about -22 m. The deviation between the two methods is fairly consistent, suggesting no gross errors in either, but rather a cumulative systematic error. It is suspected that the cumulative error is in the direct method because the geodetic method is based on a non-changing reference, the bedrock control, whereas the direct method is measured with reference to only the previous year's summer surface. Possible sources of mass loss that are missing from the direct method are basal melt, internal melt, and ablation on crevasse walls. Possible systematic measurement errors include under-estimation of the density of lost material, sinking stakes, or poorly represented areas.
Khamis, Sam; Carmeli, Eli
2017-09-01
Controversy still exists as to the clinical significance of leg length discrepancy (LLD) in spite of the fact that further evidence has been emerging regarding the relationship between several clinical conditions and LLD. The objectives of our study were to review the available research with regard to LLD as a cause of clinically significant gait deviations, to determine if there is a relationship between the magnitude of LLD and the presence of gait deviations and to identify the most common gait deviations associated with LLD. In line with the PRISMA guidelines, a literature search was carried out throughout the Medline, CINAHL and EMBASE databases. Twelve articles met the predetermined inclusion criteria and were included in the review. Quality assessment using the Methodological Index for Non-Randomized Studies (MINORS) scale was completed for all included studies. Two main methodologies were found in 4 studies evaluating gait asymmetry in patients or healthy participants with anatomic LLD and 8 studies evaluating gait deviations while simulating LLD by employing artificial lifts of 1-5cm on healthy subjects. A significant relationship was found between anatomic LLD and gait deviation. Evidence suggests that gait deviations may occur with discrepancies of >1cm, with greater impact seen as the discrepancy increases. Compensatory strategies were found to occur in both the shorter and longer limb, throughout the lower limb. As the discrepancy increases, more compensatory strategies occur. Sagittal plane deviations seem to be the most effective deviations, although, frontal plane compensations also occur in the pelvis, hip and foot. Copyright © 2017 Elsevier B.V. All rights reserved.
21 CFR 862.1660 - Quality control material (assayed and unassayed).
Code of Federal Regulations, 2013 CFR
2013-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry... control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations...
21 CFR 862.1660 - Quality control material (assayed and unassayed).
Code of Federal Regulations, 2014 CFR
2014-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry... control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations...
21 CFR 862.1660 - Quality control material (assayed and unassayed).
Code of Federal Regulations, 2012 CFR
2012-04-01
... SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry... control material (assayed and unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations...
Tests of local Lorentz invariance violation of gravity in the standard model extension with pulsars.
Shao, Lijing
2014-03-21
The standard model extension is an effective field theory introducing all possible Lorentz-violating (LV) operators to the standard model and general relativity (GR). In the pure-gravity sector of minimal standard model extension, nine coefficients describe dominant observable deviations from GR. We systematically implemented 27 tests from 13 pulsar systems to tightly constrain eight linear combinations of these coefficients with extensive Monte Carlo simulations. It constitutes the first detailed and systematic test of the pure-gravity sector of minimal standard model extension with the state-of-the-art pulsar observations. No deviation from GR was detected. The limits of LV coefficients are expressed in the canonical Sun-centered celestial-equatorial frame for the convenience of further studies. They are all improved by significant factors of tens to hundreds with existing ones. As a consequence, Einstein's equivalence principle is verified substantially further by pulsar experiments in terms of local Lorentz invariance in gravity.
A meta-analysis of instructional systems applied in science teaching
NASA Astrophysics Data System (ADS)
Willett, John B.; Yamashita, June J. M.; Anderson, Ronald D.
This article is a report of a meta-analysis on the question: What are the effects of different instructional systems used in science teaching? The studies utilized in this meta-analysis were identified by a process that included a systematic screening of all dissertations completed in the field of science education since 1950, an ERIC search of the literature, a systematic screening of selected research journals, and the standard procedure of identifying potentially relevant studies through examination of the bibliographies of the studies reviewed. In all, the 130 studies coded gave rise to 341 effect sizes. The mean effect size produced over all systems was 0.10 with a standard deviation of 0.41, indicating that, on the average, an innovative teaching system in this sample produced one-tenth of a standard deviation better performance than traditional science teaching. Particular kinds of teaching systems, however, produced results that varied from this overall result. Mean effect sizes were also computed by year of publication, form of publication, grade level, and subject matter.
Inter-technique validation of tropospheric slant total delays
NASA Astrophysics Data System (ADS)
Kačmařík, Michal; Douša, Jan; Dick, Galina; Zus, Florian; Brenot, Hugues; Möller, Gregor; Pottiaux, Eric; Kapłon, Jan; Hordyniec, Paweł; Václavovic, Pavel; Morel, Laurent
2017-06-01
An extensive validation of line-of-sight tropospheric slant total delays (STD) from Global Navigation Satellite Systems (GNSS), ray tracing in numerical weather prediction model (NWM) fields and microwave water vapour radiometer (WVR) is presented. Ten GNSS reference stations, including collocated sites, and almost 2 months of data from 2013, including severe weather events were used for comparison. Seven institutions delivered their STDs based on GNSS observations processed using 5 software programs and 11 strategies enabling to compare rather different solutions and to assess the impact of several aspects of the processing strategy. STDs from NWM ray tracing came from three institutions using three different NWMs and ray-tracing software. Inter-techniques evaluations demonstrated a good mutual agreement of various GNSS STD solutions compared to NWM and WVR STDs. The mean bias among GNSS solutions not considering post-fit residuals in STDs was -0.6 mm for STDs scaled in the zenith direction and the mean standard deviation was 3.7 mm. Standard deviations of comparisons between GNSS and NWM ray-tracing solutions were typically 10 mm ± 2 mm (scaled in the zenith direction), depending on the NWM model and the GNSS station. Comparing GNSS versus WVR STDs reached standard deviations of 12 mm ± 2 mm also scaled in the zenith direction. Impacts of raw GNSS post-fit residuals and cleaned residuals on optimal reconstructing of GNSS STDs were evaluated at inter-technique comparison and for GNSS at collocated sites. The use of raw post-fit residuals is not generally recommended as they might contain strong systematic effects, as demonstrated in the case of station LDB0. Simplified STDs reconstructed only from estimated GNSS tropospheric parameters, i.e. without applying post-fit residuals, performed the best in all the comparisons; however, it obviously missed part of tropospheric signals due to non-linear temporal and spatial variations in the troposphere. Although the post-fit residuals cleaned of visible systematic errors generally showed a slightly worse performance, they contained significant tropospheric signal on top of the simplified model. They are thus recommended for the reconstruction of STDs, particularly during high variability in the troposphere. Cleaned residuals also showed a stable performance during ordinary days while containing promising information about the troposphere at low-elevation angles.
NASA Astrophysics Data System (ADS)
Tannenbaum, Michael
2017-01-01
Although it was demonstrated more than 13 years ago that the increase in midrapidity dNch / dη with increasing centrality of Au+Au collisions at RHIC was linearly proportional to the number of constituent quark participants (or ``wounded quarks'', QW) in the collision, it was only in the last few years that generating the spatial positions of the three quarks in a nucleon according to the Fourier transform of the measured electric charge form factor of the proton could be used to connect dNch / dη /QW as a function of centrality in p(d) +A and A +A collisions with the same value of dNch / dη /QW determined in p +p collisions. One calculation, which only compared its calculated dNch / dη /QW in p +p at √{sNN} = 200 GeV to the least central of 12 centrality bin measurements in Au +Au by PHENIX, claimed that the p +p value was higher by ``about 30%'' from the band of measurements vs. centrality. However the clearly quoted systematic errors were ignored for which a 1 standard deviation systematic shift would move all the 12 Au +Au data points to within 1.3 standard deviations of the p +p value, or if the statistical and systematic errors are added in quadrature a difference of 35 +/- 21%. Rearch supported by U.S. Department of Energy, Contract No. DE-SC0012704.
A Visual Model for the Variance and Standard Deviation
ERIC Educational Resources Information Center
Orris, J. B.
2011-01-01
This paper shows how the variance and standard deviation can be represented graphically by looking at each squared deviation as a graphical object--in particular, as a square. A series of displays show how the standard deviation is the size of the average square.
Suppression of Systematic Errors of Electronic Distance Meters for Measurement of Short Distances
Braun, Jaroslav; Štroner, Martin; Urban, Rudolf; Dvořáček, Filip
2015-01-01
In modern industrial geodesy, high demands are placed on the final accuracy, with expectations currently falling below 1 mm. The measurement methodology and surveying instruments used have to be adjusted to meet these stringent requirements, especially the total stations as the most often used instruments. A standard deviation of the measured distance is the accuracy parameter, commonly between 1 and 2 mm. This parameter is often discussed in conjunction with the determination of the real accuracy of measurements at very short distances (5–50 m) because it is generally known that this accuracy cannot be increased by simply repeating the measurement because a considerable part of the error is systematic. This article describes the detailed testing of electronic distance meters to determine the absolute size of their systematic errors, their stability over time, their repeatability and the real accuracy of their distance measurement. Twenty instruments (total stations) have been tested, and more than 60,000 distances in total were measured to determine the accuracy and precision parameters of the distance meters. Based on the experiments’ results, calibration procedures were designed, including a special correction function for each instrument, whose usage reduces the standard deviation of the measurement of distance by at least 50%. PMID:26258777
Suppression of Systematic Errors of Electronic Distance Meters for Measurement of Short Distances.
Braun, Jaroslav; Štroner, Martin; Urban, Rudolf; Dvoček, Filip
2015-08-06
In modern industrial geodesy, high demands are placed on the final accuracy, with expectations currently falling below 1 mm. The measurement methodology and surveying instruments used have to be adjusted to meet these stringent requirements, especially the total stations as the most often used instruments. A standard deviation of the measured distance is the accuracy parameter, commonly between 1 and 2 mm. This parameter is often discussed in conjunction with the determination of the real accuracy of measurements at very short distances (5-50 m) because it is generally known that this accuracy cannot be increased by simply repeating the measurement because a considerable part of the error is systematic. This article describes the detailed testing of electronic distance meters to determine the absolute size of their systematic errors, their stability over time, their repeatability and the real accuracy of their distance measurement. Twenty instruments (total stations) have been tested, and more than 60,000 distances in total were measured to determine the accuracy and precision parameters of the distance meters. Based on the experiments' results, calibration procedures were designed, including a special correction function for each instrument, whose usage reduces the standard deviation of the measurement of distance by at least 50%.
Triplet energy differences and the low lying structure of 62Ga
NASA Astrophysics Data System (ADS)
Henry, T. W.; Bentley, M. A.; Clark, R. M.; Davies, P. J.; Bader, V. M.; Baugher, T.; Bazin, D.; Beausang, C. W.; Berryman, J. S.; Bruce, A. M.; Campbell, C. M.; Crawford, H. L.; Cromaz, M.; Fallon, P.; Gade, A.; Henderson, J.; Iwasaki, H.; Jenkins, D. G.; Lee, I. Y.; Lemasson, A.; Lenzi, S. M.; Macchiavelli, A. O.; Napoli, D. R.; Nichols, A. J.; Paschalis, S.; Petri, M.; Recchia, F.; Rissanen, J.; Simpson, E. C.; Stroberg, S. R.; Wadsworth, R.; Weisshaar, D.; Wiens, A.; Walz, C.
2015-08-01
Background: Triplet energy differences (TED) can be studied to yield information on isospin-non-conserving interactions in nuclei. Purpose: The systematic behavior of triplet energy differences (TED) of T =1 , Jπ=2+ states is examined. The A =62 isobar is identified as having a TED value that deviates significantly from an otherwise very consistent trend. This deviation can be attributed to the tentative assignments of the pertinent states in 62Ga and 62Ge . Methods: An in-beam γ -ray spectroscopy experiment was performed to identify excited states in 62Ga using Gamma-Ray Energy Tracking In-Beam Nuclear Array with the S800 spectrometer at NSCL using a two-nucleon knockout approach. Cross-section calculations for the knockout process and shell-model calculations have been performed to interpret the population and decay properties observed. Results: Using the systematics as a guide, a candidate for the transition from the T =1 , 2+ state is identified. However, previous work has identified similar states with different Jπ assignments. Cross-section calculations indicate that the relevant T =1 , 2+ state should be one of the states directly populated in this reaction. Conclusions: As spins and parities were not measurable, it is concluded that an unambiguous identification of the first T =1 , 2+ state is required to reconcile our understanding of TED systematics.
TH-AB-201-01: A Feasibility Study of Independent Dose Verification for CyberKnife
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sato, A; Noda, T; Keduka, Y
2016-06-15
Purpose: CyberKnife irradiation is composed of tiny-size, multiple and intensity-modulated beams compared to conventional linacs. Few of the publications for Independent dose calculation verification for CyberKnife have been reported. In this study, we evaluated the feasibility of independent dose verification for CyberKnife treatment as Secondary check. Methods: The followings were measured: test plans using some static and single beams, clinical plans in a phantom and using patient’s CT. 75 patient plans were collected from several treatment sites of brain, lung, liver and bone. In the test plans and the phantom plans, a pinpoint ion-chamber measurement was performed to assess dosemore » deviation for a treatment planning system (TPS) and an independent verification program of Simple MU Analysis (SMU). In the clinical plans, dose deviation between the SMU and the TPS was performed. Results: In test plan, the dose deviations were 3.3±4.5%, and 4.1±4.4% for the TPS and the SMU, respectively. In the phantom measurements for the clinical plans, the dose deviations were −0.2±3.6% for the TPS and −2.3±4.8% for the SMU. In the clinical plans using the patient’s CT, the dose deviations were −3.0±2.1% (Mean±1SD). The systematic difference was partially derived from inverse square law and penumbra calculation. Conclusion: The independent dose calculation for CyberKnife shows −3.0±4.2% (Mean±2SD) and our study, the confidence limit was achieved within 5% of the tolerance level from AAPM task group 114 for non-IMRT treatment. Thus, it may be feasible to use independent dose calculation verification for CyberKnife treatment as the secondary check. This research is partially supported by Japan Agency for Medical Research and Development (AMED)« less
Numerical Large Deviation Analysis of the Eigenstate Thermalization Hypothesis
NASA Astrophysics Data System (ADS)
Yoshizawa, Toru; Iyoda, Eiki; Sagawa, Takahiro
2018-05-01
A plausible mechanism of thermalization in isolated quantum systems is based on the strong version of the eigenstate thermalization hypothesis (ETH), which states that all the energy eigenstates in the microcanonical energy shell have thermal properties. We numerically investigate the ETH by focusing on the large deviation property, which directly evaluates the ratio of athermal energy eigenstates in the energy shell. As a consequence, we have systematically confirmed that the strong ETH is indeed true even for near-integrable systems. Furthermore, we found that the finite-size scaling of the ratio of athermal eigenstates is a double exponential for nonintegrable systems. Our result illuminates the universal behavior of quantum chaos, and suggests that a large deviation analysis would serve as a powerful method to investigate thermalization in the presence of the large finite-size effect.
The neural basis of financial risk taking.
Kuhnen, Camelia M; Knutson, Brian
2005-09-01
Investors systematically deviate from rationality when making financial decisions, yet the mechanisms responsible for these deviations have not been identified. Using event-related fMRI, we examined whether anticipatory neural activity would predict optimal and suboptimal choices in a financial decision-making task. We characterized two types of deviations from the optimal investment strategy of a rational risk-neutral agent as risk-seeking mistakes and risk-aversion mistakes. Nucleus accumbens activation preceded risky choices as well as risk-seeking mistakes, while anterior insula activation preceded riskless choices as well as risk-aversion mistakes. These findings suggest that distinct neural circuits linked to anticipatory affect promote different types of financial choices and indicate that excessive activation of these circuits may lead to investing mistakes. Thus, consideration of anticipatory neural mechanisms may add predictive power to the rational actor model of economic decision making.
Leecaster, Molly K; Weir, Charlene R; Drews, Frank A; Hellewell, James L; Bolton, Daniel; Jones, Makoto M; Nebeker, Jonathan R
2017-07-01
Electronic health records (EHRs) continue to be criticized for providing poor cognitive support. Defining cognitive support has lacked theoretical foundation. We developed a measurement model of cognitive support based on the Contextual Control Model (COCOM), which describes control characteristics of an "orderly" joint system and proposes 4 levels of control: scrambled, opportunistic, tactical, and strategic. 35 clinicians (5 centers) were interviewed pre and post outpatient clinical visits and audiotaped during the visit. Behaviors pertaining to hypertension management were systematically mapped to the COCOM control characteristics of: (1) time horizon, (2) uncertainty assessment, (3) consideration of multiple goals, (4) causal model described, and (5) explicitness of plan. Each encounter was classified for overall mode of control. Visits with deviation versus no deviation from hypertension goals were compared. Reviewer agreement was high. Control characteristics differed significantly between deviation groups (Wilcox rank sum p<.01). K-means cluster analysis of control characteristics, stratified by deviation were distinct, with higher goal deviations associated with more control characteristics. The COCOM control characteristics appear to be areas of potential yield for improved user-experience design. Published by Elsevier Inc.
Random matrix approach to cross correlations in financial data
NASA Astrophysics Data System (ADS)
Plerou, Vasiliki; Gopikrishnan, Parameswaran; Rosenow, Bernd; Amaral, Luís A.; Guhr, Thomas; Stanley, H. Eugene
2002-06-01
We analyze cross correlations between price fluctuations of different stocks using methods of random matrix theory (RMT). Using two large databases, we calculate cross-correlation matrices
NASA Astrophysics Data System (ADS)
Stier, P.; Schutgens, N. A. J.; Bellouin, N.; Bian, H.; Boucher, O.; Chin, M.; Ghan, S.; Huneeus, N.; Kinne, S.; Lin, G.; Ma, X.; Myhre, G.; Penner, J. E.; Randles, C. A.; Samset, B.; Schulz, M.; Takemura, T.; Yu, F.; Yu, H.; Zhou, C.
2013-03-01
Simulated multi-model "diversity" in aerosol direct radiative forcing estimates is often perceived as a measure of aerosol uncertainty. However, current models used for aerosol radiative forcing calculations vary considerably in model components relevant for forcing calculations and the associated "host-model uncertainties" are generally convoluted with the actual aerosol uncertainty. In this AeroCom Prescribed intercomparison study we systematically isolate and quantify host model uncertainties on aerosol forcing experiments through prescription of identical aerosol radiative properties in twelve participating models. Even with prescribed aerosol radiative properties, simulated clear-sky and all-sky aerosol radiative forcings show significant diversity. For a purely scattering case with globally constant optical depth of 0.2, the global-mean all-sky top-of-atmosphere radiative forcing is -4.47 Wm-2 and the inter-model standard deviation is 0.55 Wm-2, corresponding to a relative standard deviation of 12%. For a case with partially absorbing aerosol with an aerosol optical depth of 0.2 and single scattering albedo of 0.8, the forcing changes to 1.04 Wm-2, and the standard deviation increases to 1.01 W-2, corresponding to a significant relative standard deviation of 97%. However, the top-of-atmosphere forcing variability owing to absorption (subtracting the scattering case from the case with scattering and absorption) is low, with absolute (relative) standard deviations of 0.45 Wm-2 (8%) clear-sky and 0.62 Wm-2 (11%) all-sky. Scaling the forcing standard deviation for a purely scattering case to match the sulfate radiative forcing in the AeroCom Direct Effect experiment demonstrates that host model uncertainties could explain about 36% of the overall sulfate forcing diversity of 0.11 Wm-2 in the AeroCom Direct Radiative Effect experiment. Host model errors in aerosol radiative forcing are largest in regions of uncertain host model components, such as stratocumulus cloud decks or areas with poorly constrained surface albedos, such as sea ice. Our results demonstrate that host model uncertainties are an important component of aerosol forcing uncertainty that require further attention.
Saltzman, B M; Frank, J M; Slikker, W; Fernandez, J J; Cohen, M S; Wysocki, R W
2015-06-01
We conducted a systematic review of studies reporting clinical outcomes after proximal row carpectomy or to four-corner arthrodesis for scaphoid non-union advanced collapse or scapholunate advanced collapse arthritis. Seven studies (Levels I-III; 240 patients, 242 wrists) were evaluated. Significantly different post-operative values were as follows for four-corner arthrodesis versus proximal row carpectomy groups: wrist extension, 39 (SD 11º) versus 43 (SD 11º); wrist flexion, 32 (SD 10º) versus 36 (SD 11º); flexion-extension arc, 62 (SD 14º) versus 75 (SD 10º); radial deviation, 14 (SD 5º) versus 10 (SD 5º); hand grip strength as a percentage of contralateral side, 74% (SD 13) versus 67% (SD 16); overall complication rate, 29% versus 14%. The most common post-operative complications were non-union (grouped incidence, 7%) after four-corner arthrodesis and synovitis and clinically significant oedema (3.1%) after proximal row carpectomy. Radial deviation and post-operative hand grip strength (as a percentage of the contralateral side) were significantly better after four-corner arthrodesis. Four-corner arthrodesis gave significantly greater post-operative radial deviation and grip strength as a percentage of the opposite side. Wrist flexion, extension, and the flexion-extension arc were better after proximal row carpectomy, which also had a lower overall complication rate. © The Author(s) 2014.
An approximate fluvial equilibrium topography for the Alps
NASA Astrophysics Data System (ADS)
Stüwe, K.; Hergarten, S.
2012-04-01
This contribution addresses the question whether the present topography of the Alps can be approximated by a fluvial equilibrium topography and whether this can be used to determine uplift rates. Based on a statistical analysis of the present topography we use a stream-power approach for erosion where the erosion rate is proportional to the square root of the catchment size for catchment sizes larger than 12 square kilometers and a logarithmic dependence to mimic slope processes at smaller catchment sizes. If we assume a homogeneous uplift rate over the entire region (block uplift), the best-fit fluvial equilibrium topography differs from the real topography by about 500 m RMS (root mean square) with a strong systematic deviation. Regions of low elevation are too high in the equilibrium topography, while high-mountain regions are too low. The RMS difference significantly decreases if a spatially variable uplift function is allowed. If a strong variation of the uplift rate on a scale of 5 km is allowed, the systematic deviation becomes rather small, and the RMS difference decreases to about 150 m. A significant part of the remaining deviation apparently arises from glacially-shaped valleys, while another part may result from prematurity of the relief (Hergarten, Wagner & Stüwe, EPSL 297:453, 2010). The best-fit uplift function can probably be used for forward or backward simulation of the landform evolution.
NASA Astrophysics Data System (ADS)
Brousmiche, S.; Souris, K.; Orban de Xivry, J.; Lee, J. A.; Macq, B.; Seco, J.
2017-11-01
Proton range random and systematic uncertainties are the major factors undermining the advantages of proton therapy, namely, a sharp dose falloff and a better dose conformality for lower doses in normal tissues. The influence of CT artifacts such as beam hardening or scatter can easily be understood and estimated due to their large-scale effects on the CT image, like cupping and streaks. In comparison, the effects of weakly-correlated stochastic noise are more insidious and less attention is drawn on them partly due to the common belief that they only contribute to proton range uncertainties and not to systematic errors thanks to some averaging effects. A new source of systematic errors on the range and relative stopping powers (RSP) has been highlighted and proved not to be negligible compared to the 3.5% uncertainty reference value used for safety margin design. Hence, we demonstrate that the angular points in the HU-to-RSP calibration curve are an intrinsic source of proton range systematic error for typical levels of zero-mean stochastic CT noise. Systematic errors on RSP of up to 1% have been computed for these levels. We also show that the range uncertainty does not generally vary linearly with the noise standard deviation. We define a noise-dependent effective calibration curve that better describes, for a given material, the RSP value that is actually used. The statistics of the RSP and the range continuous slowing down approximation (CSDA) have been analytically derived for the general case of a calibration curve obtained by the stoichiometric calibration procedure. These models have been validated against actual CSDA simulations for homogeneous and heterogeneous synthetical objects as well as on actual patient CTs for prostate and head-and-neck treatment planning situations.
The Morphosyntax of Discontinuous Exponence
ERIC Educational Resources Information Center
Campbell, Amy Melissa
2012-01-01
This thesis offers a systematic treatment of discontinuous exponence, a pattern of inflection in which a single feature or a set of features bundled in syntax is expressed by multiple, distinct morphemes. This pattern is interesting and theoretically relevant because it represents a deviation from the expected one-to-one relationship between…
European Starlings Are Capable of Discriminating Subtle Size Asymmetries in Paired Stimuli
ERIC Educational Resources Information Center
Swaddle, John P.; Johnson, Charles W.
2007-01-01
Small deviations from bilateral symmetry (fluctuating asymmetries) are cues to fitness differences in some animals. Therefore, researchers have considered whether animals use these small asymmetries as visual cues to determine appropriate behavioral responses (e.g., mate preferences). However, there have been few systematic studies of animals'…
NASA Astrophysics Data System (ADS)
Del Giudice, Dario; Löwe, Roland; Madsen, Henrik; Mikkelsen, Peter Steen; Rieckermann, Jörg
2015-07-01
In urban rainfall-runoff, commonly applied statistical techniques for uncertainty quantification mostly ignore systematic output errors originating from simplified models and erroneous inputs. Consequently, the resulting predictive uncertainty is often unreliable. Our objective is to present two approaches which use stochastic processes to describe systematic deviations and to discuss their advantages and drawbacks for urban drainage modeling. The two methodologies are an external bias description (EBD) and an internal noise description (IND, also known as stochastic gray-box modeling). They emerge from different fields and have not yet been compared in environmental modeling. To compare the two approaches, we develop a unifying terminology, evaluate them theoretically, and apply them to conceptual rainfall-runoff modeling in the same drainage system. Our results show that both approaches can provide probabilistic predictions of wastewater discharge in a similarly reliable way, both for periods ranging from a few hours up to more than 1 week ahead of time. The EBD produces more accurate predictions on long horizons but relies on computationally heavy MCMC routines for parameter inferences. These properties make it more suitable for off-line applications. The IND can help in diagnosing the causes of output errors and is computationally inexpensive. It produces best results on short forecast horizons that are typical for online applications.
Gaschler, Robert; Progscha, Johanna; Smallbone, Kieran; Ram, Nilam; Bilalić, Merim
2014-01-01
Learning curves have been proposed as an adequate description of learning processes, no matter whether the processes manifest within minutes or across years. Different mechanisms underlying skill acquisition can lead to differences in the shape of learning curves. In the current study, we analyze the tournament performance data of 1383 chess players who begin competing at young age and play tournaments for at least 10 years. We analyze the performance development with the goal to test the adequacy of learning curves, and the skill acquisition theories they are based on, for describing and predicting expertise acquisition. On the one hand, we show that the skill acquisition theories implying a negative exponential learning curve do a better job in both describing early performance gains and predicting later trajectories of chess performance than those theories implying a power function learning curve. On the other hand, the learning curves of a large proportion of players show systematic qualitative deviations from the predictions of either type of skill acquisition theory. While skill acquisition theories predict larger performance gains in early years and smaller gains in later years, a substantial number of players begin to show substantial improvements with a delay of several years (and no improvement in the first years), deviations not fully accounted for by quantity of practice. The current work adds to the debate on how learning processes on a small time scale combine to large-scale changes.
Dohn, A O; Jónsson, E Ö; Levi, G; Mortensen, J J; Lopez-Acevedo, O; Thygesen, K S; Jacobsen, K W; Ulstrup, J; Henriksen, N E; Møller, K B; Jónsson, H
2017-12-12
A multiscale density functional theory-quantum mechanics/molecular mechanics (DFT-QM/MM) scheme is presented, based on an efficient electrostatic coupling between the electronic density obtained from a grid-based projector augmented wave (GPAW) implementation of density functional theory and a classical potential energy function. The scheme is implemented in a general fashion and can be used with various choices for the descriptions of the QM or MM regions. Tests on H 2 O clusters, ranging from dimer to decamer show that no systematic energy errors are introduced by the coupling that exceeds the differences in the QM and MM descriptions. Over 1 ns of liquid water, Born-Oppenheimer QM/MM molecular dynamics (MD) are sampled combining 10 parallel simulations, showing consistent liquid water structure over the QM/MM border. The method is applied in extensive parallel MD simulations of an aqueous solution of the diplatinum [Pt 2 (P 2 O 5 H 2 ) 4 ] 4- complex (PtPOP), spanning a total time period of roughly half a nanosecond. An average Pt-Pt distance deviating only 0.01 Å from experimental results, and a ground-state Pt-Pt oscillation frequency deviating by <2% from experimental results were obtained. The simulations highlight a remarkable harmonicity of the Pt-Pt oscillation, while also showing clear signs of Pt-H hydrogen bonding and directional coordination of water molecules along the Pt-Pt axis of the complex.
On the importance of image formation optics in the design of infrared spectroscopic imaging systems
Mayerich, David; van Dijk, Thomas; Walsh, Michael; Schulmerich, Matthew; Carney, P. Scott
2014-01-01
Infrared spectroscopic imaging provides micron-scale spatial resolution with molecular contrast. While recent work demonstrates that sample morphology affects the recorded spectrum, considerably less attention has been focused on the effects of the optics, including the condenser and objective. This analysis is extremely important, since it will be possible to understand effects on recorded data and provides insight for reducing optical effects through rigorous microscope design. Here, we present a theoretical description and experimental results that demonstrate the effects of commonly-employed cassegranian optics on recorded spectra. We first combine an explicit model of image formation and a method for quantifying and visualizing the deviations in recorded spectra as a function of microscope optics. We then verify these simulations with measurements obtained from spatially heterogeneous samples. The deviation of the computed spectrum from the ideal case is quantified via a map which we call a deviation map. The deviation map is obtained as a function of optical elements by systematic simulations. Examination of deviation maps demonstrates that the optimal optical configuration for minimal deviation is contrary to prevailing practice in which throughput is maximized for an instrument without a sample. This report should be helpful for understanding recorded spectra as a function of the optics, the analytical limits of recorded data determined by the optical design, and potential routes for optimization of imaging systems. PMID:24936526
On the importance of image formation optics in the design of infrared spectroscopic imaging systems.
Mayerich, David; van Dijk, Thomas; Walsh, Michael J; Schulmerich, Matthew V; Carney, P Scott; Bhargava, Rohit
2014-08-21
Infrared spectroscopic imaging provides micron-scale spatial resolution with molecular contrast. While recent work demonstrates that sample morphology affects the recorded spectrum, considerably less attention has been focused on the effects of the optics, including the condenser and objective. This analysis is extremely important, since it will be possible to understand effects on recorded data and provides insight for reducing optical effects through rigorous microscope design. Here, we present a theoretical description and experimental results that demonstrate the effects of commonly-employed cassegranian optics on recorded spectra. We first combine an explicit model of image formation and a method for quantifying and visualizing the deviations in recorded spectra as a function of microscope optics. We then verify these simulations with measurements obtained from spatially heterogeneous samples. The deviation of the computed spectrum from the ideal case is quantified via a map which we call a deviation map. The deviation map is obtained as a function of optical elements by systematic simulations. Examination of deviation maps demonstrates that the optimal optical configuration for minimal deviation is contrary to prevailing practice in which throughput is maximized for an instrument without a sample. This report should be helpful for understanding recorded spectra as a function of the optics, the analytical limits of recorded data determined by the optical design, and potential routes for optimization of imaging systems.
SU-E-T-613: Dosimetric Consequences of Systematic MLC Leaf Positioning Errors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kathuria, K; Siebers, J
2014-06-01
Purpose: The purpose of this study is to determine the dosimetric consequences of systematic MLC leaf positioning errors for clinical IMRT patient plans so as to establish detection tolerances for quality assurance programs. Materials and Methods: Dosimetric consequences were simulated by extracting mlc delivery instructions from the TPS, altering the file by the specified error, reloading the delivery instructions into the TPS, recomputing dose, and extracting dose-volume metrics for one head-andneck and one prostate patient. Machine error was simulated by offsetting MLC leaves in Pinnacle in a systematic way. Three different algorithms were followed for these systematic offsets, and aremore » as follows: a systematic sequential one-leaf offset (one leaf offset in one segment per beam), a systematic uniform one-leaf offset (same one leaf offset per segment per beam) and a systematic offset of a given number of leaves picked uniformly at random from a given number of segments (5 out of 10 total). Dose to the PTV and normal tissue was simulated. Results: A systematic 5 mm offset of 1 leaf for all delivery segments of all beams resulted in a maximum PTV D98 deviation of 1%. Results showed very low dose error in all reasonably possible machine configurations, rare or otherwise, which could be simulated. Very low error in dose to PTV and OARs was shown in all possible cases of one leaf per beam per segment being offset (<1%), or that of only one leaf per beam being offset (<.2%). The errors resulting from a high number of adjacent leaves (maximum of 5 out of 60 total leaf-pairs) being simultaneously offset in many (5) of the control points (total 10–18 in all beams) per beam, in both the PTV and the OARs analyzed, were similarly low (<2–3%). Conclusions: The above results show that patient shifts and anatomical changes are the main source of errors in dose delivered, not machine delivery. These two sources of error are “visually complementary” and uncorrelated (albeit not additive in the final error) and one can easily incorporate error resulting from machine delivery in an error model based purely on tumor motion.« less
Measurement tools for the diagnosis of nasal septal deviation: a systematic review
2014-01-01
Objective To perform a systematic review of measurement tools utilized for the diagnosis of nasal septal deviation (NSD). Methods Electronic database searches were performed using MEDLINE (from 1966 to second week of August 2013), EMBASE (from 1966 to second week of August 2013), Web of Science (from 1945 to second week of August 2013) and all Evidence Based Medicine Reviews Files (EBMR); Cochrane Database of Systematic Review (CDSR), Cochrane Central Register of Controlled Trials (CCTR), Cochrane Methodology Register (CMR), Database of Abstracts of Reviews of Effects (DARE), American College of Physicians Journal Club (ACP Journal Club), Health Technology Assessments (HTA), NHS Economic Evaluation Database (NHSEED) till the second quarter of 2013. The search terms used in database searches were ‘nasal septum’, ‘deviation’, ‘diagnosis’, ‘nose deformities’ and ‘nose malformation’. The studies were reviewed using the updated Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Results Online searches resulted in 23 abstracts after removal of duplicates that resulted from overlap of studies between the electronic databases. An additional 15 abstracts were excluded due to lack of relevance. A total of 8 studies were systematically reviewed. Conclusions Diagnostic modalities such as acoustic rhinometry, rhinomanometry and nasal spectral sound analysis may be useful in identifying NSD in anterior region of the nasal cavity, but these tests in isolation are of limited utility. Compared to anterior rhinoscopy, nasal endoscopy, and imaging the above mentioned index tests lack sensitivity and specificity in identifying the presence, location, and severity of NSD. PMID:24762010
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takahashi, R; Kamima, T; Tachibana, H
2016-06-15
Purpose: To investigate the effect of the trajectory files from linear accelerator for Clarkson-based independent dose verification in IMRT and VMAT plans. Methods: A CT-based independent dose verification software (Simple MU Analysis: SMU, Triangle Products, Japan) with a Clarksonbased algorithm was modified to calculate dose using the trajectory log files. Eclipse with the three techniques of step and shoot (SS), sliding window (SW) and Rapid Arc (RA) was used as treatment planning system (TPS). In this study, clinically approved IMRT and VMAT plans for prostate and head and neck (HN) at two institutions were retrospectively analyzed to assess the dosemore » deviation between DICOM-RT plan (PL) and trajectory log file (TJ). An additional analysis was performed to evaluate MLC error detection capability of SMU when the trajectory log files was modified by adding systematic errors (0.2, 0.5, 1.0 mm) and random errors (5, 10, 30 mm) to actual MLC position. Results: The dose deviations for prostate and HN in the two sites were 0.0% and 0.0% in SS, 0.1±0.0%, 0.1±0.1% in SW and 0.6±0.5%, 0.7±0.9% in RA, respectively. The MLC error detection capability shows the plans for HN IMRT were the most sensitive and 0.2 mm of systematic error affected 0.7% dose deviation on average. Effect of the MLC random error did not affect dose error. Conclusion: The use of trajectory log files including actual information of MLC location, gantry angle, etc should be more effective for an independent verification. The tolerance level for the secondary check using the trajectory file may be similar to that of the verification using DICOM-RT plan file. From the view of the resolution of MLC positional error detection, the secondary check could detect the MLC position error corresponding to the treatment sites and techniques. This research is partially supported by Japan Agency for Medical Research and Development (AMED)« less
Reproducibility of geometrical acquisition of intra-thoracic organs of children on CT scans.
Coulongeat, François; Jarrar, Mohamed-Salah; Serre, Thierry; Thollon, Lionel
2011-08-01
This paper analyses geometry of intra-thoracic organs from computed tomography (CT) scans performed on 20 children aged from 4 months to 16 years. A set of two measurements on lungs and heart were performed by the same observer. A third set was performed by a second observer. Thus, the intra- and inter-observer relative deviation of measurements was analysed. Multiple regressions were used in order to study the relationship between the CT properties (scanner, voltage, dose, pixel size, slice increment) and the relative deviation of measurements. There is a very low systematic intra- and inter-observer bias in measurements except for the volume of the heart. None of the CT data properties has a significant influence on the relative deviation of measurement. In the present paper, the measurements and 3D reconstruction protocol described can be applied to characterise the growth of the intra-thoracic organs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dowdell, S; Grassberger, C; Paganetti, H
2014-06-01
Purpose: Evaluate the sensitivity of intensity-modulated proton therapy (IMPT) lung treatments to systematic and random setup uncertainties combined with motion effects. Methods: Treatment plans with single-field homogeneity restricted to ±20% (IMPT-20%) were compared to plans with no restriction (IMPT-full). 4D Monte Carlo simulations were performed for 10 lung patients using the patient CT geometry with either ±5mm systematic or random setup uncertainties applied over a 35 × 2.5Gy(RBE) fractionated treatment course. Intra-fraction, inter-field and inter-fraction motions were investigated. 50 fractionated treatments with systematic or random setup uncertainties applied to each fraction were generated for both IMPT delivery methods and threemore » energy-dependent spot sizes (big spots - BS σ=18-9mm, intermediate spots - IS σ=11-5mm, small spots - SS σ=4-2mm). These results were compared to a Monte Carlo recalculation of the original treatment plan, with results presented as the difference in EUD (ΔEUD), V{sub 95} (ΔV{sub 95}) and target homogeneity (ΔD{sub 1}–D{sub 99}) between the 4D simulations and the Monte Carlo calculation on the planning CT. Results: The standard deviations in the ΔEUD were 1.95±0.47(BS), 1.85±0.66(IS) and 1.31±0.35(SS) times higher in IMPT-full compared to IMPT-20% when ±5mm systematic setup uncertainties were applied. The ΔV{sub 95} variations were also 1.53±0.26(BS), 1.60±0.50(IS) and 1.38±0.38(SS) times higher for IMPT-full. For random setup uncertainties, the standard deviations of the ΔEUD from 50 simulated fractionated treatments were 1.94±0.90(BS), 2.13±1.08(IS) and 1.45±0.57(SS) times higher in IMPTfull compared to IMPT-20%. For all spot sizes considered, the ΔD{sub 1}-D{sub 99} coincided within the uncertainty limits for the two IMPT delivery methods, with the mean value always higher for IMPT-full. Statistical analysis showed significant differences between the IMPT-full and IMPT-20% dose distributions for the majority of scenarios studied. Conclusion: Lung IMPT-full treatments are more sensitive to both systematic and random setup uncertainties compared to IMPT-20%. This work was supported by the NIH R01 CA111590.« less
NASA Astrophysics Data System (ADS)
Pötzi, Werner; Veronig, Astrid M.; Temmer, Manuela; Baumgartner, Dietmar J.; Freislich, Heinrich; Strutzmann, Heinz
2016-11-01
The Kanzelhöhe Observatory (KSO) was founded during World War II by the Deutsche Luftwaffe (German Airforce) as one station of a network of observatories that were set up to provide information on solar activity in order to better assess the actual conditions of the Earth's ionosphere in terms of radio-wave propagation. Solar observations began in 1943 with photographs of the photosphere and drawings of sunspots, plage regions, and faculae, as well as patrol observations of the solar corona. At the beginning, all data were sent to Freiburg (Germany). After WW II, international cooperation was established and the data were sent to Zurich, Paris, Moscow, and Greenwich. Relative sunspot numbers have been derived since 1944. The agreement between relative sunspot numbers derived at KSO and the new International Sunspot Number (ISN) (SILSO World Data Center in International Sunspot Number Monthly Bulletin and online catalogue, 1945 - 2015) lies within {≈} 10 %. However, revisiting the historical data, we also find periods with larger deviations. The reasons for the deviations were twofold: On the one hand, a major instrumental change took place during which the instrument was relocated and modified. On the other hand, a period of frequent replacements of personnel caused significant deviations; this clearly shows the importance of experienced observers. In the long term, the instrumental improvements led to better image quality. Additionally, we find a long-term trend towards better seeing conditions that began in 2000.
Back-arc spreading of the northern Izu-Ogasawara (Bonin) Islands arc clarified by GPS data
NASA Astrophysics Data System (ADS)
Nishimura, Takuya
2011-11-01
We examined GPS data in the northwestern Pacific region, which includes the Izu-Ogasawara (Bonin)-Mariana (IBM) arc and the Japan arc. GPS velocity vectors on the Izu Islands, including Hachijo-jima and Aoga-shima, show systematic eastward movement deviating from that predicted by the rigid rotation of the Philippine Sea plate; this deviation supports the active back-arc spreading model suggested by previous geological studies. The results of a statistical F-test analysis with 99% confidence level showed that the forearc of the Izu Islands arc has an independent motion with respect to the rigid part of the Philippine Sea plate. We developed a kinematic block-fault model to estimate both rigid rotations of crustal blocks and elastic deformation due to locked faults on the block boundaries. The model suggests that the back-arc opening rate along the Izu back-arc rift zone ranges from 2 mm/yr at its southern end to 9 mm/yr near Miyake-jima, its northern end. It also predicts 23-28 mm/yr of relative motion along the Sagami Trough in the direction of ~ N25°W, where the Izu forearc subducts beneath central Japan. The orientation of this motion is supported by slip vectors of recent medium-size earthquakes, repeated slow-slip events, and the 1923 M = 7.9 Kanto earthquake.
Polarization reconstruction algorithm for a Compton polarimeter
NASA Astrophysics Data System (ADS)
Vockert, M.; Weber, G.; Spillmann, U.; Krings, T.; Stöhlker, Th
2018-05-01
We present the technique of Compton polarimetry using X-ray detectors based on double-sided segmented semiconductor crystals that were developed within the SPARC collaboration. In addition, we discuss the polarization reconstruction algorithm with particular emphasis on systematic deviations between the observed detector response and our model function for the Compton scattering distribution inside the detector.
Corrected Launch Speed for a Projectile Motion Laboratory
ERIC Educational Resources Information Center
Sanders, Justin M.; Boleman, Michael W.
2013-01-01
At our university, students in introductory physics classes perform a laboratory exercise to measure the range of a projectile fired at an assigned angle. A set of photogates is used to determine the initial velocity of the projectile (the launch velocity). We noticed a systematic deviation between the experimentally measured range and the range…
Parents' and Teachers' Differing Views of Short Children's Behavior.
ERIC Educational Resources Information Center
Holmes, Clarissa S.; And Others
Children over two standard deviations below height expectations have been described by researchers as being behaviorally immature and shown to be emotionally inhibited. The present study seeks to extend these findings by systematically evaluating what role age, sex, and etiology factors may have in the behavioral adjustment of groups of children…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petyuk, Vladislav A.; Mayampurath, Anoop M.; Monroe, Matthew E.
2009-12-16
Hybrid two-stage mass spectrometers capable of both highly accurate mass measurement and MS/MS fragmentation have become widely available in recent years and have allowed for sig-nificantly better discrimination between true and false MS/MS pep-tide identifications by applying relatively narrow windows for maxi-mum allowable deviations for parent ion mass measurements. To fully gain the advantage of highly accurate parent ion mass meas-urements, it is important to limit systematic mass measurement errors. The DtaRefinery software tool can correct systematic errors in parent ion masses by reading a set of fragmentation spectra, searching for MS/MS peptide identifications, then fitting a model that canmore » estimate systematic errors, and removing them. This results in a new fragmentation spectrum file with updated parent ion masses.« less
Das, Biswajit; Gangopadhyay, Gautam
2018-05-07
In the framework of large deviation theory, we have characterized nonequilibrium turnover statistics of enzyme catalysis in a chemiostatic flow with externally controllable parameters, like substrate injection rate and mechanical force. In the kinetics of the process, we have shown the fluctuation theorems in terms of the symmetry of the scaled cumulant generating function (SCGF) in the transient and steady state regime and a similar symmetry rule is reflected in a large deviation rate function (LDRF) as a property of the dissipation rate through boundaries. Large deviation theory also gives the thermodynamic force of a nonequilibrium steady state, as is usually recorded experimentally by a single molecule technique, which plays a key role responsible for the dynamical symmetry of the SCGF and LDRF. Using some special properties of the Legendre transformation, here, we have provided a relation between the fluctuations of fluxes and dissipation rates, and among them, the fluctuation of the turnover rate is routinely estimated but the fluctuation in the dissipation rate is yet to be characterized for small systems. Such an enzymatic reaction flow system can be a very good testing ground to systematically understand the rare events from the large deviation theory which is beyond fluctuation theorem and central limit theorem.
NASA Astrophysics Data System (ADS)
Das, Biswajit; Gangopadhyay, Gautam
2018-05-01
In the framework of large deviation theory, we have characterized nonequilibrium turnover statistics of enzyme catalysis in a chemiostatic flow with externally controllable parameters, like substrate injection rate and mechanical force. In the kinetics of the process, we have shown the fluctuation theorems in terms of the symmetry of the scaled cumulant generating function (SCGF) in the transient and steady state regime and a similar symmetry rule is reflected in a large deviation rate function (LDRF) as a property of the dissipation rate through boundaries. Large deviation theory also gives the thermodynamic force of a nonequilibrium steady state, as is usually recorded experimentally by a single molecule technique, which plays a key role responsible for the dynamical symmetry of the SCGF and LDRF. Using some special properties of the Legendre transformation, here, we have provided a relation between the fluctuations of fluxes and dissipation rates, and among them, the fluctuation of the turnover rate is routinely estimated but the fluctuation in the dissipation rate is yet to be characterized for small systems. Such an enzymatic reaction flow system can be a very good testing ground to systematically understand the rare events from the large deviation theory which is beyond fluctuation theorem and central limit theorem.
Systematic comparison of static and dynamic headspace sampling techniques for gas chromatography.
Kremser, Andreas; Jochmann, Maik A; Schmidt, Torsten C
2016-09-01
Six automated, headspace-based sample preparation techniques were used to extract volatile analytes from water with the goal of establishing a systematic comparison between commonly available instrumental alternatives. To that end, these six techniques were used in conjunction with the same gas chromatography instrument for analysis of a common set of volatile organic carbon (VOC) analytes. The methods were thereby divided into three classes: static sampling (by syringe or loop), static enrichment (SPME and PAL SPME Arrow), and dynamic enrichment (ITEX and trap sampling). For PAL SPME Arrow, different sorption phase materials were also included in the evaluation. To enable an effective comparison, method detection limits (MDLs), relative standard deviations (RSDs), and extraction yields were determined and are discussed for all techniques. While static sampling techniques exhibited sufficient extraction yields (approx. 10-20 %) to be reliably used down to approx. 100 ng L(-1), enrichment techniques displayed extraction yields of up to 80 %, resulting in MDLs down to the picogram per liter range. RSDs for all techniques were below 27 %. The choice on one of the different instrumental modes of operation (aforementioned classes) was thereby the most influential parameter in terms of extraction yields and MDLs. Individual methods inside each class showed smaller deviations, and the least influences were observed when evaluating different sorption phase materials for the individual enrichment techniques. The option of selecting specialized sorption phase materials may, however, be more important when analyzing analytes with different properties such as high polarity or the capability of specific molecular interactions. Graphical Abstract PAL SPME Arrow during the extraction of volatile analytes from the headspace of an aqueous sample.
NASA Astrophysics Data System (ADS)
Flemming, Burghard W.
2017-08-01
This study investigates the effect of particle shape on the transport and deposition of mixed siliciclastic-bioclastic sediments in the lower mesotidal Langebaan Lagoon along the South Atlantic coast of South Africa. As the two sediment components have undergone mutual sorting for the last 7 ka, they can be expected to have reached a highest possible degree of hydraulic equivalence. A comparison of sieve and settling tube data shows that, with progressive coarsening of the size fractions, the mean diameters of individual sediment components increasingly depart from the spherical quartz standard, the experimental data demonstrating the hydraulic incompatibility of the sieve data. Overall, the spatial distribution patterns of textural parameters (mean settling diameter, sorting and skewness) of the siliciclastic and bioclastic sediment components are very similar. Bivariate plots between them reveal linear trends when averaged over small intervals. A systematic deviation is observed in sorting, the trend ranging from uniformity at poorer sorting levels to a progressively increasing lag of the bioclastic component relative to the siliciclastic one as overall sorting improves. The deviation amounts to 0.8 relative sorting units at the optimal sorting level. The small textural differences between the two components are considered to reflect the influence of particle shape, which prevents the bioclastic fraction from achieving complete textural equivalence with the siliciclastic one. This is also reflected in the inferred transport behaviour of the two shape components, the bioclastic fraction moving closer to the bed than the siliciclastic one because of the higher drag experienced by low shape factor particles. As a consequence, the bed-phase development of bioclastic sediments departs significantly from that of siliciclastic sediments. Systematic flume experiments, however, are currently still lacking.
NASA Astrophysics Data System (ADS)
Lazarina, Maria; Kallimanis, Athanasios S.; Pantis, John D.; Sgardelis, Stefanos P.
2014-11-01
The species-area relationship (SAR) is one of the few generalizations in ecology. However, many different relationships are denoted as SARs. Here, we empirically evaluated the differences between SARs derived from nested-contiguous and non-contiguous sampling designs, using plants, birds and butterflies datasets from Great Britain, Greece, Massachusetts, New York and San Diego. The shape of SAR depends on the sampling scheme, but there is little empirical documentation on the magnitude of the deviation between different types of SARs and the factors affecting it. We implemented a strictly nested sampling design to construct nested-contiguous SAR (SACR), and systematic nested but non-contiguous, and random designs to construct non-contiguous species richness curves (SASRs for systematic and SACs for random designs) per dataset. The SACR lay below any SASR and most of the SACs. The deviation between them was related to the exponent f of the power law relationship between sampled area and extent. The lower the exponent f, the higher was the deviation between the curves. We linked SACR to SASR and SAC through the concept of "effective" area (Ae), i.e. the nested-contiguous area containing equal number of species with the accumulated sampled area (AS) of a non-contiguous sampling. The relationship between effective and sampled area was modeled as log(Ae) = klog(AS). A Generalized Linear Model was used to estimate the values of k from sampling design and dataset properties. The parameter k increased with the average distance between samples and with beta diversity, while k decreased with f. For both systematic and random sampling, the model performed well in predicting effective area in both the training set and in the test set which was totally independent from the training one. Through effective area, we can link different types of species richness curves based on sampling design properties, sampling effort, spatial scale and beta diversity patterns.
NASA Astrophysics Data System (ADS)
Schweitzer, Susanne; Nemitz, Wolfgang; Sommer, Christian; Hartmann, Paul; Fulmek, Paul; Nicolics, Johann; Pachler, Peter; Hoschopf, Hans; Schrank, Franz; Langer, Gregor; Wenzl, Franz P.
2014-09-01
For a systematic approach to improve the white light quality of phosphor converted light-emitting diodes (LEDs) for general lighting applications it is imperative to get the individual sources of error for color temperature reproducibility under control. In this regard, it is imperative to understand how compositional, optical and materials properties of the color conversion element (CCE), which typically consists of phosphor particles embedded in a transparent matrix material, affect the constancy of a desired color temperature of a white LED source. In this contribution we use an LED assembly consisting of an LED die mounted on a printed circuit board (PCB) by chip-on-board technology and a CCE with a glob-top configuration as a model system and discuss the impact of potential sources for color temperature deviation among individual devices. Parameters that are investigated include imprecisions in the amount of materials deposition, deviations from the target value for the phosphor concentration in the matrix material, deviations from the target value for the particle sizes of the phosphor material, deviations from the target values for the refractive indexes of phosphor and matrix material as well as deviations from the reflectivity of the substrate surface. From these studies, some general conclusions can be drawn which of these parameters have the largest impact on color deviation and have to be controlled most precisely in a fabrication process in regard of color temperature reproducibility among individual white LED sources.
Alternative sampling designs and estimators for annual surveys
Paul C. Van Deusen
2000-01-01
Annual forest inventory systems in the United States have generally converged on sampling designs that: (1) measure equal proportions of the total number of plots each year; and (2) call for the plots to be systematically dispersed. However, there will inevitably be a need to deviate from the basic design to respond to special requests, natural disasters, and budgetary...
ERIC Educational Resources Information Center
Niedzielski, Henri
1970-01-01
This article suggests applying the methods of linguistic investigation which dialectologists use in field work to the systematically programmed training of foreign language teachers in hearing and correcting the phonemic deviations in their students' pronunciation of the target language. (Author/FB)
Pressure beneath the Surface of a Fluid: Measuring the Correct Depth
ERIC Educational Resources Information Center
McCall, Richard P.
2013-01-01
Systematic errors can cause measurements to deviate from the actual value of the quantity being measured. Faulty equipment (such as a meterstick that is not marked correctly), inaccurate calibration of measuring devices (such as a scale to measure mass that has not been properly zeroed), and improper use of equipment by the experimenter (such as…
Hoche, S; Hussein, M A; Becker, T
2015-03-01
The accuracy of density, reflection coefficient, and acoustic impedance determination via multiple reflection method was validated experimentally. The ternary system water-maltose-ethanol was used to execute a systematic, temperature dependent study over a wide range of densities and viscosities aiming an application as inline sensor in beverage industries. The validation results of the presented method and setup show root mean square errors of: 1.201E-3 g cm(-3) (±0.12%) density, 0.515E-3 (0.15%) reflection coefficient and 1.851E+3 kg s(-1) m(-2) (0.12%) specific acoustic impedance. The results of the diffraction corrected absorption showed an average standard deviation of only 0.12%. It was found that the absorption change shows a good correlation to concentration variations and may be useful for laboratory analysis of sufficiently pure liquids. The main part of the observed errors can be explained by the observed noise, temperature variation and the low signal resolution of 50 MHz. In particular, the poor signal-to-noise ratio of the second reflector echo was found to be a main accuracy limitation. Concerning the investigation of liquids the unstable properties of the reference material PMMA, due to hygroscopicity, were identified to be an additional, unpredictable source of uncertainty. While dimensional changes can be considered by adequate methodology, the impact of the time and temperature dependent water absorption on relevant reference properties like the buffer's sound velocity and density could not be considered and may explain part of the observed deviations. Copyright © 2014 Elsevier B.V. All rights reserved.
Ronchi, Roberta; Revol, Patrice; Katayama, Masahiro; Rossetti, Yves; Farnè, Alessandro
2011-01-01
During the procedure of prism adaptation, subjects execute pointing movements to visual targets under a lateral optical displacement: As consequence of the discrepancy between visual and proprioceptive inputs, their visuo-motor activity is characterized by pointing errors. The perception of such final errors triggers error-correction processes that eventually result into sensori-motor compensation, opposite to the prismatic displacement (i.e., after-effects). Here we tested whether the mere observation of erroneous pointing movements, similar to those executed during prism adaptation, is sufficient to produce adaptation-like after-effects. Neurotypical participants observed, from a first-person perspective, the examiner's arm making incorrect pointing movements that systematically overshot visual targets location to the right, thus simulating a rightward optical deviation. Three classical after-effect measures (proprioceptive, visual and visual-proprioceptive shift) were recorded before and after first-person's perspective observation of pointing errors. Results showed that mere visual exposure to an arm that systematically points on the right-side of a target (i.e., without error correction) produces a leftward after-effect, which mostly affects the observer's proprioceptive estimation of her body midline. In addition, being exposed to such a constant visual error induced in the observer the illusion “to feel” the seen movement. These findings indicate that it is possible to elicit sensori-motor after-effects by mere observation of movement errors. PMID:21731649
Sokolenko, Stanislav; Aucoin, Marc G
2015-09-04
The growing ubiquity of metabolomic techniques has facilitated high frequency time-course data collection for an increasing number of applications. While the concentration trends of individual metabolites can be modeled with common curve fitting techniques, a more accurate representation of the data needs to consider effects that act on more than one metabolite in a given sample. To this end, we present a simple algorithm that uses nonparametric smoothing carried out on all observed metabolites at once to identify and correct systematic error from dilution effects. In addition, we develop a simulation of metabolite concentration time-course trends to supplement available data and explore algorithm performance. Although we focus on nuclear magnetic resonance (NMR) analysis in the context of cell culture, a number of possible extensions are discussed. Realistic metabolic data was successfully simulated using a 4-step process. Starting with a set of metabolite concentration time-courses from a metabolomic experiment, each time-course was classified as either increasing, decreasing, concave, or approximately constant. Trend shapes were simulated from generic functions corresponding to each classification. The resulting shapes were then scaled to simulated compound concentrations. Finally, the scaled trends were perturbed using a combination of random and systematic errors. To detect systematic errors, a nonparametric fit was applied to each trend and percent deviations calculated at every timepoint. Systematic errors could be identified at time-points where the median percent deviation exceeded a threshold value, determined by the choice of smoothing model and the number of observed trends. Regardless of model, increasing the number of observations over a time-course resulted in more accurate error estimates, although the improvement was not particularly large between 10 and 20 samples per trend. The presented algorithm was able to identify systematic errors as small as 2.5 % under a wide range of conditions. Both the simulation framework and error correction method represent examples of time-course analysis that can be applied to further developments in (1)H-NMR methodology and the more general application of quantitative metabolomics.
Khosravi, H R; Nodehi, Mr Golrokh; Asnaashari, Kh; Mahdavi, S R; Shirazi, A R; Gholami, S
2012-07-01
The aim of this study was to evaluate and analytically compare different calculation algorithms applied in our country radiotherapy centers base on the methodology developed by IAEA for treatment planning systems (TPS) commissioning (IAEA TEC-DOC 1583). Thorax anthropomorphic phantom (002LFC CIRS inc.), was used to measure 7 tests that simulate the whole chain of external beam TPS. The dose were measured with ion chambers and the deviation between measured and TPS calculated dose was reported. This methodology, which employs the same phantom and the same setup test cases, was tested in 4 different hospitals which were using 5 different algorithms/ inhomogeneity correction methods implemented in different TPS. The algorithms in this study were divided into two groups including correction based and model based algorithms. A total of 84 clinical test case datasets for different energies and calculation algorithms were produced, which amounts of differences in inhomogeneity points with low density (lung) and high density (bone) was decreased meaningfully with advanced algorithms. The number of deviations outside agreement criteria was increased with the beam energy and decreased with advancement of the TPS calculation algorithm. Large deviations were seen in some correction based algorithms, so sophisticated algorithms, would be preferred in clinical practices, especially for calculation in inhomogeneous media. Use of model based algorithms with lateral transport calculation, is recommended. Some systematic errors which were revealed during this study, is showing necessity of performing periodic audits on TPS in radiotherapy centers. © 2012 American Association of Physicists in Medicine.
Makundi, Emmanuel; Kapiriri, Lydia; Norheim, Ole Frithjof
2007-09-24
Procedures for priority setting need to incorporate both scientific evidence and public values. The aim of this study was to test out a model for priority setting which incorporates both scientific evidence and public values, and to explore use of evidence by a selection of stakeholders and to study reasons for the relative ranking of health care interventions in a setting of extreme resource scarcity. Systematic search for and assessment of relevant evidence for priority setting in a low-income country. Development of a balance sheet according to Eddy's explicit method. Eight group interviews (n-85), using a modified nominal group technique for eliciting individual and group rankings of a given set of health interventions. The study procedure made it possible to compare the groups' ranking before and after all the evidence was provided to participants. A rank deviation is significant if the rank order of the same intervention differed by two or more points on the ordinal scale. A comparison between the initial rank and the final rank (before deliberation) showed a rank deviation of 67%. The difference between the initial rank and the final rank after discussion and voting gave a rank deviation of 78%. Evidence-based and deliberative decision-making does change priorities significantly in an experimental setting. Our use of the balance sheet method was meant as a demonstration project, but could if properly developed be feasible for health planners, experts and health workers, although more work is needed before it can be used for laypersons.
Luminosity and Stellar Mass Functions from the 6dF Galaxy Survey
NASA Astrophysics Data System (ADS)
Colless, M.; Jones, D. H.; Peterson, B. A.; Campbell, L.; Saunders, W.; Lah, P.
2007-12-01
The completed 6dF Galaxy Survey includes redshifts for over 124,000 galaxies. We present luminosity functions in optical and near-infrared passbands that span a range of 10^4 in luminosity. These luminosity functions show systematic deviations from the Schechter form. The corresponding luminosity densities in the optical and near-infrared are consistent with an old stellar population and a moderately declining star formation rate. Stellar mass functions, derived from the K band luminosities and simple stellar population models selected by b_J-r_F colour, lead to an estimate of the present-day stellar mass density of ρ_* = (5.00 ± 0.11) × 10^8 h M_⊙ Mpc^{-3}, corresponding to Ω_* h = (1.80 ± 0.04) × 10^{-3}.
Some methodical peculiarities of analysis of small-mass samples by SRXFA
NASA Astrophysics Data System (ADS)
Kudryashova, A. F.; Tarasov, L. S.; Ulyanov, A. A.; Baryshev, V. B.
1989-10-01
The stability of work of the element analysis station on the storage rings VEPP-3 and VEPP-4 in INP (Novosibirsk, USSR) was demonstrated on the example of three sets of rare element analyses carried out by SRXFA in May 1985, January and May-June 1988. These data show that there are some systematic deviations in the results of measurements of Zr and La contents. SRXFA and INAA data have been compared for the latter element. A false linear correlation on the Rb-Sr plot in one set of analyses has been attributed to an overlapping artificial Sr peak on a Rb peak. The authors proposed sequences of registration of spectra and computer treatment for samples and standards. Such sequences result in better final concentration data.
Understanding overlay signatures using machine learning on non-lithography context information
NASA Astrophysics Data System (ADS)
Overcast, Marshall; Mellegaard, Corey; Daniel, David; Habets, Boris; Erley, Georg; Guhlemann, Steffen; Thrun, Xaver; Buhl, Stefan; Tottewitz, Steven
2018-03-01
Overlay errors between two layers can be caused by non-lithography processes. While these errors can be compensated by the run-to-run system, such process and tool signatures are not always stable. In order to monitor the impact of non-lithography context on overlay at regular intervals, a systematic approach is needed. Using various machine learning techniques, significant context parameters that relate to deviating overlay signatures are automatically identified. Once the most influential context parameters are found, a run-to-run simulation is performed to see how much improvement can be obtained. The resulting analysis shows good potential for reducing the influence of hidden context parameters on overlay performance. Non-lithographic contexts are significant contributors, and their automatic detection and classification will enable the overlay roadmap, given the corresponding control capabilities.
NASA Astrophysics Data System (ADS)
Lippens, R. M.; Cerf, C.; Hallenga, K.
The theory of the transferred nuclear Overhauser effect is presented in the framework of an extended relaxation matrix representation. This matrix representation allows a coherent description of all one- and two-dimensional experiments. We present analytical solutions for the buildup of magnetization in the 2D transfer-NOE experiment, for all ratios of the off rate k to the cross-relaxation rates R involved. We show that systematic deviations in distance determination occur when the off rate becomes comparable to or smaller than the relaxation rates. Experimental results on the peptide/protein system oxytocin/neurophysin confirming this analysis are presented. The importance of residual mobility in the bound ligand, as demonstrated by the experimental data, is also discussed.
Systematic study of α-decay half-lives using Royer and related formula
NASA Astrophysics Data System (ADS)
Akrawy, Dashty T.; Hassanabadi, H.; Hosseini, S. S.; Santhosh, K. P.
2018-03-01
The alpha decay half-lives of 356 isotopes were studied using the Royer and related Formula and are compared with experimental data. The study shows that the predicted half-lives match well with experimental data over a wide range for each (Z , N) parity of the parent nuclei. We have calculated the standard deviation of log10 Tα (s), for each formula and our study indicate that, for alpha decay studies, generally, analytical ℓ-dependent formula proposed by Royer, with σRB = 0.4373, is the best model followed by the formula proposed by Denisov and Khudenko (DK), σDK = 0.4743 for all 356 nuclei. We hope the present study is a clear indicator of the predictive power of Royer and related formula.
A Brief Critique of the TATES Procedure.
Aliev, Fazil; Salvatore, Jessica E; Agrawal, Arpana; Almasy, Laura; Chan, Grace; Edenberg, Howard J; Hesselbrock, Victor; Kuperman, Samuel; Meyers, Jacquelyn; Dick, Danielle M
2018-03-01
The Trait-based test that uses the Extended Simes procedure (TATES) was developed as a method for conducting multivariate GWAS for correlated phenotypes whose underlying genetic architecture is complex. In this paper, we provide a brief methodological critique of the TATES method using simulated examples and a mathematical proof. Our simulated examples using correlated phenotypes show that the Type I error rate is higher than expected, and that more TATES p values fall outside of the confidence interval relative to expectation. Thus the method may result in systematic inflation when used with correlated phenotypes. In a mathematical proof we further demonstrate that the distribution of TATES p values deviates from expectation in a manner indicative of inflation. Our findings indicate the need for caution when using TATES for multivariate GWAS of correlated phenotypes.
Hinton-Bayre, Anton D
2011-02-01
There is an ongoing debate over the preferred method(s) for determining the reliable change (RC) in individual scores over time. In the present paper, specificity comparisons of several classic and contemporary RC models were made using a real data set. This included a more detailed review of a new RC model recently proposed in this journal, that used the within-subjects standard deviation (WSD) as the error term. It was suggested that the RC(WSD) was more sensitive to change and theoretically superior. The current paper demonstrated that even in the presence of mean practice effects, false-positive rates were comparable across models when reliability was good and initial and retest variances were equivalent. However, when variances differed, discrepancies in classification across models became evident. Notably, the RC using the WSD provided unacceptably high false-positive rates in this setting. It was considered that the WSD was never intended for measuring change in this manner. The WSD actually combines systematic and error variance. The systematic variance comes from measurable between-treatment differences, commonly referred to as practice effect. It was further demonstrated that removal of the systematic variance and appropriate modification of the residual error term for the purpose of testing individual change yielded an error term already published and criticized in the literature. A consensus on the RC approach is needed. To that end, further comparison of models under varied conditions is encouraged.
Lantry, B.F.; Rudstam, L. G.; Forney, J.L.; VanDeValk, A.J.; Mills, E.L.; Stewart, D.J.; Adams, J.V.
2008-01-01
Daily consumption was estimated from the stomach contents of walleyes Sander vitreus collected weekly from Oneida Lake, New York, during June-October 1975, 1992, 1993, and 1994 for one to four age-groups per year. Field rations were highly variable between weeks, and trends in ration size varied both seasonally and annually. The coefficient of variation for weekly field rations within years and ages ranged from 45% to 97%. Field estimates were compared with simulated consumption from a bioenergetics model. The simulation averages of daily ration deviated from those of the field estimates by -20.1% to +70.3%, with a mean across all simulations of +14.3%. The deviations for each time step were much greater than those for the simulation averages, ranging from -92.8% to +363.6%. A systematic trend in the deviations was observed, the model producing overpredictions at rations less than 3.7% of body weight. Analysis of variance indicated that the deviations were affected by sample year and week but not age. Multiple linear regression using backwards selection procedures and Akaike's information criterion indicated that walleye weight, walleye growth, lake temperature, prey energy density, and the proportion of gizzard shad Dorosoma cepedianum in the diet significantly affected the deviations between simulated and field rations and explained 32% of the variance. ?? Copyright by the American Fisheries Society 2008.
[Risk factors and burnout levels in Primary Care nurses: A systematic review].
Gómez-Urquiza, Jose L; Monsalve-Reyes, Carolina S; San Luis-Costas, Concepción; Fernández-Castillo, Rafael; Aguayo-Estremera, Raimundo; Cañadas-de la Fuente, Guillermo A
2017-02-01
To determine the risk factors and levels of burnout in Primary Care nurses. A systematic review was performed. CINAHL, CUIDEN, LILACS, PubMed, ProQuest, ScienceDirect and Scopus databases were consulted. Search equations were 'burnout AND community health nursing' and 'burnout AND primary care nursing'. The search was performed in October 2015. The final sample was n=12 studies. Quantitative primary studies that used Maslach Burnout Inventory for burnout assessment in Primary Care nurses were included without restriction by publication date. The main variables were the mean and standard deviation of the three burnout dimensions, high, medium and low prevalence rates of each dimension, and socio-demographic, occupational and psychological variables that potentially influence burnout level. Studies show high prevalence rates, generally between 23% and 31%, of emotional exhaustion. The prevalence rates of high depersonalisation and low personal accomplishment show heterogeneity, varying between 8%-32% and 4%-92% of the sample, respectively. Studies show that older nurses with more seniority, anxiety and depression, among other variables, have higher burnout levels, while nurses with higher salary, high job satisfaction, organisational support, and good self-concept have less burnout. High emotional exhaustion is the main affected dimension of burnout in Primary Care nursing. There is heterogeneity in depersonalisation and personal accomplishment. Burnout must be prevented in these professionals, by increasing protective factors and monitoring its appearance in those with risk factors. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Flores-Alamo, Marcos; del Carmen Romero-Quiroz, María; Morgado, Jorge
2010-01-01
In the title compound {systematic name: 2-[(E)-but-2-en-1-yl]isoindoline-1,3-dione}, C12H11NO2, the phthalimide ring system is essentially planar, with a maximum deviation of 0.008 (1) Å, while the plane of the N-crotyl substituent is orthogonal to the phthalimide ring system, making a dihedral angle of 87.5 (1)°. PMID:21589502
Equilibrium figures in geodesy and geophysics.
NASA Astrophysics Data System (ADS)
Moritz, H.
There is an enormous literature on geodetic equilibrium figures, but the various works have not always been interrelated, also for linguistic reasons (English, French, German, Italian, Russian). The author attempts to systematize the various approaches and to use the standard second-order theory for a study of the deviation of the actual earth and of the equipotential reference ellipsoid from an equilibrium figure.
Decision Making Under Uncertainty
2010-11-01
A sound approach to rational decision making requires a decision maker to establish decision objectives, identify alternatives, and evaluate those...often violate the axioms of rationality when making decisions under uncertainty. The systematic description of such observations may lead to the...which leads to “anchoring” on the initial value. The fact that individuals have been shown to deviate from rationality when making decisions
Cellular Contraction and Polarization Drive Collective Cellular Motion.
Notbohm, Jacob; Banerjee, Shiladitya; Utuje, Kazage J C; Gweon, Bomi; Jang, Hwanseok; Park, Yongdoo; Shin, Jennifer; Butler, James P; Fredberg, Jeffrey J; Marchetti, M Cristina
2016-06-21
Coordinated motions of close-packed multicellular systems typically generate cooperative packs, swirls, and clusters. These cooperative motions are driven by active cellular forces, but the physical nature of these forces and how they generate collective cellular motion remain poorly understood. Here, we study forces and motions in a confined epithelial monolayer and make two experimental observations: 1) the direction of local cellular motion deviates systematically from the direction of the local traction exerted by each cell upon its substrate; and 2) oscillating waves of cellular motion arise spontaneously. Based on these observations, we propose a theory that connects forces and motions using two internal state variables, one of which generates an effective cellular polarization, and the other, through contractile forces, an effective cellular inertia. In agreement with theoretical predictions, drugs that inhibit contractility reduce both the cellular effective elastic modulus and the frequency of oscillations. Together, theory and experiment provide evidence suggesting that collective cellular motion is driven by at least two internal variables that serve to sustain waves and to polarize local cellular traction in a direction that deviates systematically from local cellular velocity. Copyright © 2016 Biophysical Society. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keeling, V; Jin, H; Hossain, S
2014-06-15
Purpose: To evaluate setup accuracy and quantify individual systematic and random errors for the various hardware and software components of the frameless 6D-BrainLAB ExacTrac system. Methods: 35 patients with cranial lesions, some with multiple isocenters (50 total lesions treated in 1, 3, 5 fractions), were investigated. All patients were simulated with a rigid head-and-neck mask and the BrainLAB localizer. CT images were transferred to the IPLAN treatment planning system where optimized plans were generated using stereotactic reference frame based on the localizer. The patients were setup initially with infrared (IR) positioning ExacTrac system. Stereoscopic X-ray images (XC: X-ray Correction) weremore » registered to their corresponding digitally-reconstructed-radiographs, based on bony anatomy matching, to calculate 6D-translational and rotational (Lateral, Longitudinal, Vertical, Pitch, Roll, Yaw) shifts. XC combines systematic errors of the mask, localizer, image registration, frame, and IR. If shifts were below tolerance (0.7 mm translational and 1 degree rotational), treatment was initiated; otherwise corrections were applied and additional X-rays were acquired to verify patient position (XV: X-ray Verification). Statistical analysis was used to extract systematic and random errors of the different components of the 6D-ExacTrac system and evaluate the cumulative setup accuracy. Results: Mask systematic errors (translational; rotational) were the largest and varied from one patient to another in the range (−15 to 4mm; −2.5 to 2.5degree) obtained from mean of XC for each patient. Setup uncertainty in IR positioning (0.97,2.47,1.62mm;0.65,0.84,0.96degree) was extracted from standard-deviation of XC. Combined systematic errors of the frame and localizer (0.32,−0.42,−1.21mm; −0.27,0.34,0.26degree) was extracted from mean of means of XC distributions. Final patient setup uncertainty was obtained from the standard deviations of XV (0.57,0.77,0.67mm,0.39,0.35,0.30degree). Conclusion: Statistical analysis was used to calculate cumulative and individual systematic errors from the different hardware and software components of the 6D-ExacTrac-system. Patients were treated with cumulative errors (<1mm,<1degree) with XV image guidance.« less
Scaling theory for information networks.
Moses, Melanie E; Forrest, Stephanie; Davis, Alan L; Lodder, Mike A; Brown, James H
2008-12-06
Networks distribute energy, materials and information to the components of a variety of natural and human-engineered systems, including organisms, brains, the Internet and microprocessors. Distribution networks enable the integrated and coordinated functioning of these systems, and they also constrain their design. The similar hierarchical branching networks observed in organisms and microprocessors are striking, given that the structure of organisms has evolved via natural selection, while microprocessors are designed by engineers. Metabolic scaling theory (MST) shows that the rate at which networks deliver energy to an organism is proportional to its mass raised to the 3/4 power. We show that computational systems are also characterized by nonlinear network scaling and use MST principles to characterize how information networks scale, focusing on how MST predicts properties of clock distribution networks in microprocessors. The MST equations are modified to account for variation in the size and density of transistors and terminal wires in microprocessors. Based on the scaling of the clock distribution network, we predict a set of trade-offs and performance properties that scale with chip size and the number of transistors. However, there are systematic deviations between power requirements on microprocessors and predictions derived directly from MST. These deviations are addressed by augmenting the model to account for decentralized flow in some microprocessor networks (e.g. in logic networks). More generally, we hypothesize a set of constraints between the size, power and performance of networked information systems including transistors on chips, hosts on the Internet and neurons in the brain.
Galli, C
2001-07-01
It is well established that the use of polychromatic radiation in spectrophotometric assays leads to excursions from the Beer-Lambert limit. This Note models the resulting systematic error as a function of assay spectral width, slope of molecular extinction coefficient, and analyte concentration. The theoretical calculations are compared with recent experimental results; a parameter is introduced which can be used to estimate the magnitude of the systematic error in both chromatographic and nonchromatographic spectrophotometric assays. It is important to realize that the polychromatic radiation employed in common laboratory equipment can yield assay errors up to approximately 4%, even at absorption levels generally considered 'safe' (i.e. absorption <1). Thus careful consideration of instrumental spectral width, analyte concentration, and slope of molecular extinction coefficient is required to ensure robust analytical methods.
Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision.
Ender, Andreas; Mehl, Albert
2013-02-01
A new approach to both 3-dimensional (3D) trueness and precision is necessary to assess the accuracy of intraoral digital impressions and compare them to conventionally acquired impressions. The purpose of this in vitro study was to evaluate whether a new reference scanner is capable of measuring conventional and digital intraoral complete-arch impressions for 3D accuracy. A steel reference dentate model was fabricated and measured with a reference scanner (digital reference model). Conventional impressions were made from the reference model, poured with Type IV dental stone, scanned with the reference scanner, and exported as digital models. Additionally, digital impressions of the reference model were made and the digital models were exported. Precision was measured by superimposing the digital models within each group. Superimposing the digital models on the digital reference model assessed the trueness of each impression method. Statistical significance was assessed with an independent sample t test (α=.05). The reference scanner delivered high accuracy over the entire dental arch with a precision of 1.6 ±0.6 µm and a trueness of 5.3 ±1.1 µm. Conventional impressions showed significantly higher precision (12.5 ±2.5 µm) and trueness values (20.4 ±2.2 µm) with small deviations in the second molar region (P<.001). Digital impressions were significantly less accurate with a precision of 32.4 ±9.6 µm and a trueness of 58.6 ±15.8µm (P<.001). More systematic deviations of the digital models were visible across the entire dental arch. The new reference scanner is capable of measuring the precision and trueness of both digital and conventional complete-arch impressions. The digital impression is less accurate and shows a different pattern of deviation than the conventional impression. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Meyer, Swanhild U.; Kaiser, Sebastian; Wagner, Carola; Thirion, Christian; Pfaffl, Michael W.
2012-01-01
Background Adequate normalization minimizes the effects of systematic technical variations and is a prerequisite for getting meaningful biological changes. However, there is inconsistency about miRNA normalization performances and recommendations. Thus, we investigated the impact of seven different normalization methods (reference gene index, global geometric mean, quantile, invariant selection, loess, loessM, and generalized procrustes analysis) on intra- and inter-platform performance of two distinct and commonly used miRNA profiling platforms. Methodology/Principal Findings We included data from miRNA profiling analyses derived from a hybridization-based platform (Agilent Technologies) and an RT-qPCR platform (Applied Biosystems). Furthermore, we validated a subset of miRNAs by individual RT-qPCR assays. Our analyses incorporated data from the effect of differentiation and tumor necrosis factor alpha treatment on primary human skeletal muscle cells and a murine skeletal muscle cell line. Distinct normalization methods differed in their impact on (i) standard deviations, (ii) the area under the receiver operating characteristic (ROC) curve, (iii) the similarity of differential expression. Loess, loessM, and quantile analysis were most effective in minimizing standard deviations on the Agilent and TLDA platform. Moreover, loess, loessM, invariant selection and generalized procrustes analysis increased the area under the ROC curve, a measure for the statistical performance of a test. The Jaccard index revealed that inter-platform concordance of differential expression tended to be increased by loess, loessM, quantile, and GPA normalization of AGL and TLDA data as well as RGI normalization of TLDA data. Conclusions/Significance We recommend the application of loess, or loessM, and GPA normalization for miRNA Agilent arrays and qPCR cards as these normalization approaches showed to (i) effectively reduce standard deviations, (ii) increase sensitivity and accuracy of differential miRNA expression detection as well as (iii) increase inter-platform concordance. Results showed the successful adoption of loessM and generalized procrustes analysis to one-color miRNA profiling experiments. PMID:22723911
A three-dimensional code for muon propagation through the rock: MUSIC
NASA Astrophysics Data System (ADS)
Antonioli, P.; Ghetti, C.; Korolkova, E. V.; Kudryavtsev, V. A.; Sartorelli, G.
1997-10-01
We present a new three-dimensional Monte-Carlo code MUSIC (MUon SImulation Code) for muon propagation through the rock. All processes of muon interaction with matter with high energy loss (including the knock-on electron production) are treated as stochastic processes. The angular deviation and lateral displacement of muons due to multiple scattering, as well as bremsstrahlung, pair production and inelastic scattering are taken into account. The code has been applied to obtain the energy distribution and angular and lateral deviations of single muons at different depths underground. The muon multiplicity distributions obtained with MUSIC and CORSIKA (Extensive Air Shower simulation code) are also presented. We discuss the systematic uncertainties of the results due to different muon bremsstrahlung cross-sections.
Expected utility violations evolve under status-based selection mechanisms.
Dickson, Eric S
2008-10-07
The expected utility theory of decision making under uncertainty, a cornerstone of modern economics, assumes that humans linearly weight "utilities" for different possible outcomes by the probabilities with which these outcomes occur. Despite the theory's intuitive appeal, both from normative and from evolutionary perspectives, many experiments demonstrate systematic, though poorly understood, patterns of deviation from EU predictions. This paper offers a novel theoretical account of such patterns of deviation by demonstrating that EU violations can emerge from evolutionary selection when individual "status" affects inclusive fitness. In humans, battles for resources and social standing involve high-stakes decision making, and assortative mating ensures that status matters for fitness outcomes. The paper therefore proposes grounding the study of decision making under uncertainty in an evolutionary game-theoretic framework.
Ganni, Sandeep; Botden, Sanne M B I; Schaap, Dennis P; Verhoeven, Bas H; Goossens, Richard H M; Jakimowicz, Jack J
To establish whether a systematized approach to self-assessment in a laparoscopic surgical skills course improves accordance between expert- and self-assessment. A systematic training course in self-assessment using Competency Assessment Tool was introduced into the normal course of evaluation within a Laparoscopic Surgical Skills training course for the test group (n = 30). Differences between these and a control group (n = 30) who did not receive the additional training were assessed. Catharina Hospital, Eindhoven, The Netherlands (n = 27), and GSL Medical College, Rajahmundry, India (n = 33). Sixty postgraduate year 2 and 3 surgical residents who attended the 2-day Laparoscopic Surgical Skills grade 1 level 1 curriculum were invited to participate. The test group (n = 30) showed better accordance between expert- and self-assessment (difference of 1.5, standard deviation [SD] = 0.2 versus 3.83, SD = 0.6, p = 0.009) as well as half the number (7 versus 14) of cases of overreporting. Furthermore, the test group also showed higher overall mean performance (mean = 38.1, SD = 0.7 versus mean = 31.8, SD = 1.0, p < 0.001) than the control group (n = 30). The systematic approach to self-assessment can be viewed as responsible for this and can be seen as "reflection-before-practice" within the framework of reflective practice as defined by Donald Schon. Our results suggest that "reflection-before-practice" in implementing self-assessment is an important step in the development of surgical skills, yielding both better understanding of one's strengths and weaknesses and also improving overall performance. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Łacka, Katarzyna; Florczak, Jolanta; Gradecka-Kubik, Ilona; Rajewska, Justyna; Junik, Roman
2010-03-01
Lack of thyroid hormones in the womb and the first years of life causes changes in the nervous system and mental retardation. The aim of the study was to assess changes in peripheral and central nervous system in 29 adult patients with primary congenital hypothyroidism (PCH) depending on the cause of the disease and systematic treatment of L-thyroxine. The analysis was performed in 29 adult patients with PCH (16 women, 13 men) on the basis of the results of neurological examination, EEG, SPECT (Computer tomography single photon emission) of the brain. Changes in the nervous system were found in 72% of respondents. Patients who had implemented replacement therapy L-thyroxine after completing 12 months of age showed the most neurological disorders. There were variations in the cranial nerves III, IX, IV and VI. In 34% of respondents revealed paraneoplastic cerebellar symptoms, while the pyramid, and extrapyramidal symptoms in 10% and 3% of the people. EEG showed changes in brain bioelectrical activity in the entire study group. In the 83% found a significant asymmetry in regional cerebral blood flow (rCBF). Hypoperfusion outbreak occurred mainly in the stands and leading occipital. The relationship between time of initiation of treatment, and the presence of a systematic change in the nervous system was inversely proportional. In turn, analyzing the causes of most PCH deviations were found in the nervous system in patients with athyreosis. Brain SPECT study in these patients confirmed the organic changes in brain development. CONCLUSIONS. The presence and extent of changes in peripheral and central nervous system depends on the cause PCH, pending the implementation of L-thyroxine treatment and systematic. Studies of brain SPECT and EEG confirmed the existence of developmental changes of the brain in patients with PCH.
FREQUENCY SHIFTS OF RESONANT MODES OF THE SUN DUE TO NEAR-SURFACE CONVECTIVE SCATTERING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhattacharya, J.; Hanasoge, S.; Antia, H. M.
Measurements of oscillation frequencies of the Sun and stars can provide important independent constraints on their internal structure and dynamics. Seismic models of these oscillations are used to connect structure and rotation of the star to its resonant frequencies, which are then compared with observations, the goal being that of minimizing the difference between the two. Even in the case of the Sun, for which structure models are highly tuned, observed frequencies show systematic deviations from modeled frequencies, a phenomenon referred to as the “surface term.” The dominant source of this systematic effect is thought to be vigorous near-surface convection,more » which is not well accounted for in both stellar modeling and mode-oscillation physics. Here we bring to bear the method of homogenization, applicable in the asymptotic limit of large wavelengths (in comparison to the correlation scale of convection), to characterize the effect of small-scale surface convection on resonant-mode frequencies in the Sun. We show that the full oscillation equations, in the presence of temporally stationary three-dimensional (3D) flows, can be reduced to an effective “quiet-Sun” wave equation with altered sound speed, Brünt–Väisäla frequency, and Lamb frequency. We derive the modified equation and relations for the appropriate averaging of 3D flows and thermal quantities to obtain the properties of this effective medium. Using flows obtained from 3D numerical simulations of near-surface convection, we quantify their effect on solar oscillation frequencies and find that they are shifted systematically and substantially. We argue therefore that consistent interpretations of resonant frequencies must include modifications to the wave equation that effectively capture the impact of vigorous hydrodynamic convection.« less
New fundamental evidence of non-classical structure in the combination of natural concepts.
Aerts, D; Sozzo, S; Veloz, T
2016-01-13
We recently performed cognitive experiments on conjunctions and negations of two concepts with the aim of investigating the combination problem of concepts. Our experiments confirmed the deviations (conceptual vagueness, underextension, overextension etc.) from the rules of classical (fuzzy) logic and probability theory observed by several scholars in concept theory, while our data were successfully modelled in a quantum-theoretic framework developed by ourselves. In this paper, we isolate a new, very stable and systematic pattern of violation of classicality that occurs in concept combinations. In addition, the strength and regularity of this non-classical effect leads us to believe that it occurs at a more fundamental level than the deviations observed up to now. It is our opinion that we have identified a deep non-classical mechanism determining not only how concepts are combined but, rather, how they are formed. We show that this effect can be faithfully modelled in a two-sector Fock space structure, and that it can be exactly explained by assuming that human thought is the superposition of two processes, a 'logical reasoning', guided by 'logic', and a 'conceptual reasoning', guided by 'emergence', and that the latter generally prevails over the former. All these findings provide new fundamental support to our quantum-theoretic approach to human cognition. © 2015 The Author(s).
The Astrometric Recognition of the Solar Clementine Gnomon (1702)
NASA Astrophysics Data System (ADS)
Sigismondi, Costantino
The Clementine gnomon has been built in 1702 to measure the Earth's obliquity variation. For this reason the pinhole was located in the walls of Diocletian's times (305 a. D.) in order to remain stable along the centuries, but its original form and position have been modified. We used an astrometric method to recover the original position of the pinhole: reshaping the pinhole to a circle of 1.5 cm of diameter, the positions of the Northern and Southern limbs have been compared with the ephemerides. A sistematic shift of 4.5 mm Southward of the whole solar image shows that the original pinhole was 4.5 mm North of the actual position, as the images in the Bianchini's book (1703) suggest. The oval shape of the actual pinhole is also wrong. Using a circle the larger solar spots are clearly visible. Some reference stars of the catalogue of Philippe de la Hire (1702), used originally for measuring the ecliptic latitude of the Sun, are written next to the meridian line, but after the last restauration (2000), four of them are wrongly located. Finally the deviation from the true North, of the meridian line's azimuth confirms the value recovered in 1750. This, with the local deviations of a true line, will remain as systematic error, like for all these historical instruments.
Heyman, Gene M.; Grisanzio, Katherine A.; Liang, Victor
2016-01-01
We tested whether principles that describe the allocation of overt behavior, as in choice experiments, also describe the allocation of cognition, as in attention experiments. Our procedure is a cognitive version of the “two-armed bandit choice procedure.” The two-armed bandit procedure has been of interest to psychologistsand economists because it tends to support patterns of responding that are suboptimal. Each of two alternatives provides rewards according to fixed probabilities. The optimal solution is to choose the alternative with the higher probability of reward on each trial. However, subjects often allocate responses so that the probability of a response approximates its probability of reward. Although it is this result which has attracted most interest, probability matching is not always observed. As a function of monetary incentives, practice, and individual differences, subjects tend to deviate from probability matching toward exclusive preference, as predicted by maximizing. In our version of the two-armed bandit procedure, the monitor briefly displayed two, small adjacent stimuli that predicted correct responses according to fixed probabilities, as in a two-armed bandit procedure. We show that in this setting, a simple linear equation describes the relationship between attention and correct responses, and that the equation’s solution is the allocation of attention between the two stimuli. The calculations showed that attention allocation varied as a function of the degree to which the stimuli predicted correct responses. Linear regression revealed a strong correlation (r = 0.99) between the predictiveness of a stimulus and the probability of attending to it. Nevertheless there were deviations from probability matching, and although small, they were systematic and statistically significant. As in choice studies, attention allocation deviated toward maximizing as a function of practice, feedback, and incentives. Our approach also predicts the frequency of correct guesses and the relationship between attention allocation and response latencies. The results were consistent with these two predictions, the assumptions of the equations used to calculate attention allocation, and recent studies which show that predictiveness and reward are important determinants of attention. PMID:27014109
Semi-supervised anomaly detection - towards model-independent searches of new physics
NASA Astrophysics Data System (ADS)
Kuusela, Mikael; Vatanen, Tommi; Malmi, Eric; Raiko, Tapani; Aaltonen, Timo; Nagai, Yoshikazu
2012-06-01
Most classification algorithms used in high energy physics fall under the category of supervised machine learning. Such methods require a training set containing both signal and background events and are prone to classification errors should this training data be systematically inaccurate for example due to the assumed MC model. To complement such model-dependent searches, we propose an algorithm based on semi-supervised anomaly detection techniques, which does not require a MC training sample for the signal data. We first model the background using a multivariate Gaussian mixture model. We then search for deviations from this model by fitting to the observations a mixture of the background model and a number of additional Gaussians. This allows us to perform pattern recognition of any anomalous excess over the background. We show by a comparison to neural network classifiers that such an approach is a lot more robust against misspecification of the signal MC than supervised classification. In cases where there is an unexpected signal, a neural network might fail to correctly identify it, while anomaly detection does not suffer from such a limitation. On the other hand, when there are no systematic errors in the training data, both methods perform comparably.
NASA Astrophysics Data System (ADS)
Joyce, Meridith; Chaboyer, Brian
2016-01-01
Synthetic Red Giant Branch Bump (RGBB) magnitudes are generated with the most recent theoretical stellar evolution models computed with the Dartmouth Stellar Evolution Program (DSEP) code. They are compared to the observational work of Nataf et al. (2013), who present RGBB magnitudes for 72 globular clusters. A DSEP model using a chemical composition with enhanced α capture [α/Fe] =+0.4 and an age of 13 Gyr shows agreement with observations over metallicities ranging from [Fe/H] = 0 to [Fe/H] ≈-1.5, with discrepancy emerging at lower metallicities. A model-independent, density-based outlier detection routine known as the Local Outlying Factor (LOF) algorithm is applied to the observations in order to identify clusters that deviate most in magnitude-metallicity space from the bulk of the observations. Our model's fit is scrutinized with a series of χ^2 routines performed on subsets of the data from which highly anomalous clusters have been selectively removed based on LOF identification. In particular, NGCs 6254, 6681, 6218, and 1904 are tagged recurrently as outliers. The effects of systematic and non-systematic error in metallicity are assessed, and the robustness of observational error bars is investigated.
NASA Astrophysics Data System (ADS)
Braun, Jaroslav; Štroner, Martin; Urban, Rudolf
2015-05-01
All surveying instruments and their measurements suffer from some errors. To refine the measurement results, it is necessary to use procedures restricting influence of the instrument errors on the measured values or to implement numerical corrections. In precise engineering surveying industrial applications the accuracy of the distances usually realized on relatively short distance is a key parameter limiting the resulting accuracy of the determined values (coordinates, etc.). To determine the size of systematic and random errors of the measured distances were made test with the idea of the suppression of the random error by the averaging of the repeating measurement, and reducing systematic errors influence of by identifying their absolute size on the absolute baseline realized in geodetic laboratory at the Faculty of Civil Engineering CTU in Prague. The 16 concrete pillars with forced centerings were set up and the absolute distances between the points were determined with a standard deviation of 0.02 millimetre using a Leica Absolute Tracker AT401. For any distance measured by the calibrated instruments (up to the length of the testing baseline, i.e. 38.6 m) can now be determined the size of error correction of the distance meter in two ways: Firstly by the interpolation on the raw data, or secondly using correction function derived by previous FFT transformation usage. The quality of this calibration and correction procedure was tested on three instruments (Trimble S6 HP, Topcon GPT-7501, Trimble M3) experimentally using Leica Absolute Tracker AT401. By the correction procedure was the standard deviation of the measured distances reduced significantly to less than 0.6 mm. In case of Topcon GPT-7501 is the nominal standard deviation 2 mm, achieved (without corrections) 2.8 mm and after corrections 0.55 mm; in case of Trimble M3 is nominal standard deviation 3 mm, achieved (without corrections) 1.1 mm and after corrections 0.58 mm; and finally in case of Trimble S6 is nominal standard deviation 1 mm, achieved (without corrections) 1.2 mm and after corrections 0.51 mm. Proposed procedure of the calibration and correction is in our opinion very suitable for increasing of the accuracy of the electronic distance measurement and allows the use of the common surveying instrument to achieve uncommonly high precision.
Computational Precision of Mental Inference as Critical Source of Human Choice Suboptimality.
Drugowitsch, Jan; Wyart, Valentin; Devauchelle, Anne-Dominique; Koechlin, Etienne
2016-12-21
Making decisions in uncertain environments often requires combining multiple pieces of ambiguous information from external cues. In such conditions, human choices resemble optimal Bayesian inference, but typically show a large suboptimal variability whose origin remains poorly understood. In particular, this choice suboptimality might arise from imperfections in mental inference rather than in peripheral stages, such as sensory processing and response selection. Here, we dissociate these three sources of suboptimality in human choices based on combining multiple ambiguous cues. Using a novel quantitative approach for identifying the origin and structure of choice variability, we show that imperfections in inference alone cause a dominant fraction of suboptimal choices. Furthermore, two-thirds of this suboptimality appear to derive from the limited precision of neural computations implementing inference rather than from systematic deviations from Bayes-optimal inference. These findings set an upper bound on the accuracy and ultimate predictability of human choices in uncertain environments. Copyright © 2016 Elsevier Inc. All rights reserved.
Two-step transition in a magnetoelectric ferrimagnet Cu2OSeO3
NASA Astrophysics Data System (ADS)
Živković, I.; Pajić, D.; Ivek, T.; Berger, H.
2012-06-01
We report a detailed single-crystal investigation of a magnetoelectric ferrimagnet Cu2OSeO3 using dc magnetization and ac susceptibility along the three principal directions [100], [110], and [111]. We have observed that in small magnetic fields two magnetic transitions occur, one at Tc=57 K and the second one at TN=58 K. At Tc the nonlinear susceptibility reveals the emergence of the ferromagnetic component and below Tc the magnetization measurements show the splitting between field-cooled and zero-field-cooled regimes. Above 1000 Oe the magnetization saturates and the system is in a single domain state. The temperature dependence of the saturation below Tc can be well described by μ(T)=μ(0)[1-(T/Tc)2]β, with μ(0)=0.56μB/Cu, corresponding to the 3-up-1-down configuration. The dielectric constant measured on a thin single crystal shows a systematic deviation below the transition, indicating an intrinsic magnetoelectric effect.
Analytical probabilistic proton dose calculation and range uncertainties
NASA Astrophysics Data System (ADS)
Bangert, M.; Hennig, P.; Oelfke, U.
2014-03-01
We introduce the concept of analytical probabilistic modeling (APM) to calculate the mean and the standard deviation of intensity-modulated proton dose distributions under the influence of range uncertainties in closed form. For APM, range uncertainties are modeled with a multivariate Normal distribution p(z) over the radiological depths z. A pencil beam algorithm that parameterizes the proton depth dose d(z) with a weighted superposition of ten Gaussians is used. Hence, the integrals ∫ dz p(z) d(z) and ∫ dz p(z) d(z)2 required for the calculation of the expected value and standard deviation of the dose remain analytically tractable and can be efficiently evaluated. The means μk, widths δk, and weights ωk of the Gaussian components parameterizing the depth dose curves are found with least squares fits for all available proton ranges. We observe less than 0.3% average deviation of the Gaussian parameterizations from the original proton depth dose curves. Consequently, APM yields high accuracy estimates for the expected value and standard deviation of intensity-modulated proton dose distributions for two dimensional test cases. APM can accommodate arbitrary correlation models and account for the different nature of random and systematic errors in fractionated radiation therapy. Beneficial applications of APM in robust planning are feasible.
Patel, K; Abbassi-Ghadi, N; Markar, S; Kumar, S; Jethwa, P; Zaninotto, G
2016-10-01
Peroral endoscopic myotomy (POEM) is a novel approach to performing esophageal myotomy for the treatment of achalasia. This review aims to assess subjective and objective metrics of achalasia treatment efficacy, perioperative adverse events and the incidence of postoperative gastroesophageal reflux disease in patients treated with POEM. Secondary aims include a pooled analysis comparison of the clinical outcomes and procedural safety of POEM versus laparoscopic Heller's myotomy (LHM). A systematic review of the literature, up to and including January 15, 2015, was conducted for studies reporting POEM outcomes. Studies comparing POEM to LHM were also included for the purpose of pooled analysis. Outcomes from 1122 POEM patients, from 22 studies, are reported in this systematic review. Minor operative adverse events included capno/pneumo-peritoneum (30.6%), capno/pneumo-thorax (11.0%) and subcutaneous emphysema (31.6%). Major operative adverse events included mediastinal leak (0.3%), postoperative bleeding (1.1%) and a single mortality (0.09%). There was an improvement in lower esophageal sphincter pressure and timed barium esophagram column height of 66% and 80% post-POEM, respectively. Symptom improvement was demonstrated with a pre- and post-POEM Eckardt score ± standard deviation of 6.8 ± 1.0 and 1.2 ± 0.6, respectively. Pre- and post-POEM endoscopy showed esophagitis in 0% and 19% of patients, respectively. The median (interquartile range) points scored for study quality was 15 (14-16) out of total of 32. Pooled analysis of three comparative studies between LHM and POEM showed similar results for adverse events, perforation rate, operative time and a nonsignificant trend toward a reduced length of hospital stay in the POEM group. In conclusion, POEM is a safe and effective treatment for achalasia, showing significant improvements in objective metrics and achalasia-related symptoms. Randomized comparative studies of LHM and POEM are required to determine the most effective treatment modality for achalasia. © 2015 International Society for Diseases of the Esophagus.
Ranking and validation of spallation models for isotopic production cross sections of heavy residua
NASA Astrophysics Data System (ADS)
Sharma, Sushil K.; Kamys, Bogusław; Goldenbaum, Frank; Filges, Detlef
2017-07-01
The production cross sections of isotopically identified residual nuclei of spallation reactions induced by 136Xe projectiles at 500AMeV on hydrogen target were analyzed in a two-step model. The first stage of the reaction was described by the INCL4.6 model of an intranuclear cascade of nucleon-nucleon and pion-nucleon collisions whereas the second stage was analyzed by means of four different models; ABLA07, GEM2, GEMINI++ and SMM. The quality of the data description was judged quantitatively using two statistical deviation factors; the H-factor and the M-factor. It was found that the present analysis leads to a different ranking of models as compared to that obtained from the qualitative inspection of the data reproduction. The disagreement was caused by sensitivity of the deviation factors to large statistical errors present in some of the data. A new deviation factor, the A factor, was proposed, that is not sensitive to the statistical errors of the cross sections. The quantitative ranking of models performed using the A-factor agreed well with the qualitative analysis of the data. It was concluded that using the deviation factors weighted by statistical errors may lead to erroneous conclusions in the case when the data cover a large range of values. The quality of data reproduction by the theoretical models is discussed. Some systematic deviations of the theoretical predictions from the experimental results are observed.
Hao, Teng-teng; Xie, Yan-ming; Liao, Xing; Wang, Jing
2015-10-01
The paper is to systematically evaluate the effect and safety of Shenqi Fuzheng injection (SFI) combined with first-line chemotherapy for non-small cell lung cancer (NSCLC). Randomized controlled trials (RCTs) on Shenqi Fuzheng injection (SFI) combined with first-line chemotherapy (experiment group) and chemotherapy alone group ( control group) were electronically retrieved from Medline, EMbase, Clinical Trials, Cochrane Library, CBM, CNKI, VIP, and Wanfang Data base. All trials were assessed for quality according to the Cochrane Reviewer's Handbook for Systematic Reviews of Intervention and then Meta-analysis was performed withRevMan5. 2 Software. A total of 43 RCTs (3433 patients) were included after screening and selecting. Results of Meta-analysis showed that: Objective remission rate (ORR): ORR of experimental group was about 20% higher than that of control group [RR = 1.23, 95% CI (1.11,1.35), P < 0.0001]. Disease control rate (DCR):DCR of SFI combined with first-line chemotherapy was 11% higher than that of first-line chemotherapy alone [RR = 1.11, 95% CI (1.07, 1.16), P < 0.000 01]. Life quality evaluated by Kosovan performance status (KPS) showed that: life quality improvement rate of experimental group was about twice of that in control group [RR = 2.02, 95% CI (1.81, 2.26), P < 0.000 01]. Toxic and side reaction analysis showed that: the incidence of side reactions in experimental group was about 50% lower than that in control group [RR = 0.59, 95% CI (0.53, 0.66), P < 0.000 01]. Immune function test showed that: the function of experimental group was 3.2 (standard deviations) times greater than that of control group [MD = 3.23, 95% CI (2.86, 3.60), P < 0.000 01]. We can see that SFI combined with first-line chemotherapy for NSCLC can increase objective efficacy, improve life quality, decrease toxic and side reactionsinduced by chemotherapy, and improve the immune functions. As most of the included studies in this systematic evaluation had poor quality, the evidence to support conclusion was weak, so it was necessary to conduct more multi-center clinical trials with high quality methods and rigorous design.
Analytical approach to chromatic correction in the final focus system of circular colliders
Cai, Yunhai
2016-11-28
Here, a conventional final focus system in particle accelerators is systematically analyzed. We find simple relations between the parameters of two focus modules in the final telescope. Using the relations, we derive the chromatic Courant-Snyder parameters for the telescope. The parameters are scaled approximately according to (L*/βmore » $$*\\atop{y}$$)δ, where L* is the distance from the interaction point to the first quadrupole, β$$*\\atop{y}$$ the vertical beta function at the interaction point, and δ the relative momentum deviation. Most importantly, we show how to compensate its chromaticity order by order in δ by a traditional correction module flanked by an asymmetric pair of harmonic multipoles. The method enables a circular Higgs collider with 2% momentum aperture and illuminates a path forward to 4% in the future.« less
Observation of the baryonic B decay B{sup 0}{yields}{Lambda}{sub c}{sup +}{Lambda}K{sup -}
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lees, J. P.; Poireau, V.; Tisserand, V.
2011-10-01
We report the observation of the baryonic B decay B{sup 0}{yields}{Lambda}{sub c}{sup +}{Lambda}K{sup -} with a significance larger than 7 standard deviations based on 471x10{sup 6} BB pairs collected with the BABAR detector at the PEP-II storage ring at SLAC. We measure the branching fraction for the decay B{sup 0}{yields}{Lambda}{sub c}{sup +}{Lambda}K{sup -} to be (3.8{+-}0.8{sub stat}{+-}0.2{sub sys}{+-}1.0{sub {Lambda}}{sub c}{sup +})x10{sup -5}. The uncertainties are statistical, systematic, and due to the uncertainty in the {Lambda}{sub c}{sup +} branching fraction. We find that the {Lambda}{sub c}{sup +}K{sup -} invariant-mass distribution shows an enhancement above 3.5 GeV/c{sup 2}.
Interobserver delineation variation in lung tumour stereotactic body radiotherapy
Persson, G F; Nygaard, D E; Hollensen, C; Munck af Rosenschöld, P; Mouritsen, L S; Due, A K; Berthelsen, A K; Nyman, J; Markova, E; Roed, A P; Roed, H; Korreman, S; Specht, L
2012-01-01
Objectives In radiotherapy, delineation uncertainties are important as they contribute to systematic errors and can lead to geographical miss of the target. For margin computation, standard deviations (SDs) of all uncertainties must be included as SDs. The aim of this study was to quantify the interobserver delineation variation for stereotactic body radiotherapy (SBRT) of peripheral lung tumours using a cross-sectional study design. Methods 22 consecutive patients with 26 tumours were included. Positron emission tomography/CT scans were acquired for planning of SBRT. Three oncologists and three radiologists independently delineated the gross tumour volume. The interobserver variation was calculated as a mean of multiple SDs of distances to a reference contour, and calculated for the transversal plane (SDtrans) and craniocaudal (CC) direction (SDcc) separately. Concordance indexes and volume deviations were also calculated. Results Median tumour volume was 13.0 cm3, ranging from 0.3 to 60.4 cm3. The mean SDtrans was 0.15 cm (SD 0.08 cm) and the overall mean SDcc was 0.26 cm (SD 0.15 cm). Tumours with pleural contact had a significantly larger SDtrans than tumours surrounded by lung tissue. Conclusions The interobserver delineation variation was very small in this systematic cross-sectional analysis, although significantly larger in the CC direction than in the transversal plane, stressing that anisotropic margins should be applied. This study is the first to make a systematic cross-sectional analysis of delineation variation for peripheral lung tumours referred for SBRT, establishing the evidence that interobserver variation is very small for these tumours. PMID:22919015
Estimating Mixed Broadleaves Forest Stand Volume Using Dsm Extracted from Digital Aerial Images
NASA Astrophysics Data System (ADS)
Sohrabi, H.
2012-07-01
In mixed old growth broadleaves of Hyrcanian forests, it is difficult to estimate stand volume at plot level by remotely sensed data while LiDar data is absent. In this paper, a new approach has been proposed and tested for estimating stand forest volume. The approach is based on this idea that forest volume can be estimated by variation of trees height at plots. In the other word, the more the height variation in plot, the more the stand volume would be expected. For testing this idea, 120 circular 0.1 ha sample plots with systematic random design has been collected in Tonekaon forest located in Hyrcanian zone. Digital surface model (DSM) measure the height values of the first surface on the ground including terrain features, trees, building etc, which provides a topographic model of the earth's surface. The DSMs have been extracted automatically from aerial UltraCamD images so that ground pixel size for extracted DSM varied from 1 to 10 m size by 1m span. DSMs were checked manually for probable errors. Corresponded to ground samples, standard deviation and range of DSM pixels have been calculated. For modeling, non-linear regression method was used. The results showed that standard deviation of plot pixels with 5 m resolution was the most appropriate data for modeling. Relative bias and RMSE of estimation was 5.8 and 49.8 percent, respectively. Comparing to other approaches for estimating stand volume based on passive remote sensing data in mixed broadleaves forests, these results are more encouraging. One big problem in this method occurs when trees canopy cover is totally closed. In this situation, the standard deviation of height is low while stand volume is high. In future studies, applying forest stratification could be studied.
Berg, Michael; Bolotin, Jakov; Hofstetter, Thomas B
2007-03-15
Solid-phase microextraction (SPME) coupled to gas chromatography/isotope ratio mass spectrometry was used to determine the delta15N and delta13C signatures of selected nitroaromatic contaminants such as the explosive 2,4,6-trinitrotoluene (TNT) for derivation of isotopic enrichment factors of contaminant transformation. Parameters for efficient extraction of nitroaromatic compounds (NACs) and substituted anilines from water samples were evaluated by SPME-GC/MS. delta13C signatures determined by SPME-GC/IRMS and elemental analyzer IRMS (EA-IRMS) were in good agreement, generally within +/-0.7 per thousand, except for 2,4-dinitrotoluene (2,4-DNT) and TNT, which showed slight deviations (<1.3 per thousand). Limits of detection (LODs) for delta13C analysis by SPME-GC/IRMS were between 73 and 780 microg L-1 and correlated with the extraction efficiencies of the compounds determined by SPME-GC/MS. Nitrogen isotope measurements by SPME-GC/IRMS were of similar precision (standard deviations <0.8 per thousand) for all NACs except for TNT. delta15N signatures matched the reference values obtained by EA-IRMS within +/-1.3 per thousand (+2.5 per thousand for TNT), but no systematic trend was found for the deviations. LODs of delta15N measurements ranged from 1.6 to 9.6 mg L-1 for nitrotoluenes, chlorinated NACs and DNTs (22 mg L-1 for TNT). The SPME-GC/IRMS method is well suited for the determination of isotopic enrichment factors of various NAC transformation processes and provides so far unexplored possibilities to elucidate behavior and degradation mechanisms of nitroaromatic contaminants in soils and groundwaters.
NASA Astrophysics Data System (ADS)
Lottermoser, Werner; Redhammer, Günther J.; Weber, Sven-Ulf; Litterst, Fred Jochen; Tippelt, Gerold; Dlugosz, Stephen; Bank, Hermann; Amthauer, Georg; Grodzicki, Michael
2011-12-01
This work reports on the evaluation of the electric field gradient (EFG) in natural chrysoberyl Al2BeO4 and sinhalite MgAlBO4 using two different procedures: (1) experimental, with single crystal Mössbauer spectroscopy (SCMBS) on the three principal sections of each sample and (2) a "fully quantitative" method with cluster molecular orbital calculations based on the density functional theory. Whereas the experimental and theoretical results for the EFG tensor are in quantitative agreement, the calculated isomer shifts and optical d-d-transitions exhibit systematic deviations from the measured values. These deviations indicate that the substitution of Al and Mg with iron should be accompanied by considerable local expansion of the coordination octahedra.
Process influences and correction possibilities for high precision injection molded freeform optics
NASA Astrophysics Data System (ADS)
Dick, Lars; Risse, Stefan; Tünnermann, Andreas
2016-08-01
Modern injection molding processes offer a cost-efficient method for manufacturing high precision plastic optics for high volume applications. Besides form deviation of molded freeform optics, internal material stress is a relevant influencing factor for the functionality of a freeform optics in an optical system. This paper illustrates dominant influence parameters of an injection molding process relating to form deviation and internal material stress based on a freeform demonstrator geometry. Furthermore, a deterministic and efficient way for 3D mold correcting of systematic, asymmetrical shrinkage errors is shown to reach micrometer range shape accuracy at diameters up to 40 mm. In a second case, a stress-optimized parameter combination using unusual molding conditions was 3D corrected to reach high precision and low stress freeform polymer optics.
Neural correlates of strategic reasoning during competitive games.
Seo, Hyojung; Cai, Xinying; Donahue, Christopher H; Lee, Daeyeol
2014-10-17
Although human and animal behaviors are largely shaped by reinforcement and punishment, choices in social settings are also influenced by information about the knowledge and experience of other decision-makers. During competitive games, monkeys increased their payoffs by systematically deviating from a simple heuristic learning algorithm and thereby countering the predictable exploitation by their computer opponent. Neurons in the dorsomedial prefrontal cortex (dmPFC) signaled the animal's recent choice and reward history that reflected the computer's exploitative strategy. The strength of switching signals in the dmPFC also correlated with the animal's tendency to deviate from the heuristic learning algorithm. Therefore, the dmPFC might provide control signals for overriding simple heuristic learning algorithms based on the inferred strategies of the opponent. Copyright © 2014, American Association for the Advancement of Science.
Optical-frequency transfer over a single-span 1840 km fiber link.
Droste, S; Ozimek, F; Udem, Th; Predehl, K; Hänsch, T W; Schnatz, H; Grosche, G; Holzwarth, R
2013-09-13
To compare the increasing number of optical frequency standards, highly stable optical signals have to be transferred over continental distances. We demonstrate optical-frequency transfer over a 1840-km underground optical fiber link using a single-span stabilization. The low inherent noise introduced by the fiber allows us to reach short term instabilities expressed as the modified Allan deviation of 2×10(-15) for a gate time τ of 1 s reaching 4×10(-19) in just 100 s. We find no systematic offset between the sent and transferred frequencies within the statistical uncertainty of about 3×10(-19). The spectral noise distribution of our fiber link at low Fourier frequencies leads to a τ(-2) slope in the modified Allan deviation, which is also derived theoretically.
Maximum Entropy, Word-Frequency, Chinese Characters, and Multiple Meanings
Yan, Xiaoyong; Minnhagen, Petter
2015-01-01
The word-frequency distribution of a text written by an author is well accounted for by a maximum entropy distribution, the RGF (random group formation)-prediction. The RGF-distribution is completely determined by the a priori values of the total number of words in the text (M), the number of distinct words (N) and the number of repetitions of the most common word (kmax). It is here shown that this maximum entropy prediction also describes a text written in Chinese characters. In particular it is shown that although the same Chinese text written in words and Chinese characters have quite differently shaped distributions, they are nevertheless both well predicted by their respective three a priori characteristic values. It is pointed out that this is analogous to the change in the shape of the distribution when translating a given text to another language. Another consequence of the RGF-prediction is that taking a part of a long text will change the input parameters (M, N, kmax) and consequently also the shape of the frequency distribution. This is explicitly confirmed for texts written in Chinese characters. Since the RGF-prediction has no system-specific information beyond the three a priori values (M, N, kmax), any specific language characteristic has to be sought in systematic deviations from the RGF-prediction and the measured frequencies. One such systematic deviation is identified and, through a statistical information theoretical argument and an extended RGF-model, it is proposed that this deviation is caused by multiple meanings of Chinese characters. The effect is stronger for Chinese characters than for Chinese words. The relation between Zipf’s law, the Simon-model for texts and the present results are discussed. PMID:25955175
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, Congwu; Zeng, Grace G.; Department of Radiation Oncology, University of Toronto, Toronto, ON
2014-08-15
We investigated the setup variations over the treatment courses of 113 patients with intact prostate treated with 78Gy/39fx. Institutional standard bladder and bowel preparation and image guidance protocols were used in CT simulation and treatment. The RapidArc treatment plans were optimized in Varian Eclipse treatment planning system and delivered on Varian 2100X Clinacs equipped with On-Board Imager to localize the target before beam-on. The setup variations were calculated in terms of mean and standard deviation of couch shifts. No correlation was observed between the mean shift and standard deviation over the treatment course and patient age, initial prostate volume andmore » rectum size. The mean shifts in the first and last 5 fractions are highly correlated (P < 10{sup −10}) while the correlation of the standard deviations cannot be determined. The Mann-Kendall tests indicate trends of the mean daily Ant-Post and Sup-Inf shifts of the group. The target is inferior by ∼1mm to the planned position when the treatment starts and moves superiorly, approaching the planned position at 10th fraction, and then gradually moves back inferiorly by ∼1mm in the remain fractions. In the Ant-Post direction, the prostate gradually moves posteriorly during the treatment course from a mean shift of ∼2.5mm in the first fraction to ∼1mm in the last fraction. It may be related to a systematic rectum size change in the progress of treatment. The biased mean shifts in Ant-Post and Sup-Inf direction of most patients suggest systematically larger rectum and smaller bladder during the treatment than at CT simulation.« less
SU-C-207A-04: Accuracy of Acoustic-Based Proton Range Verification in Water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, KC; Sehgal, CM; Avery, S
2016-06-15
Purpose: To determine the accuracy and dose required for acoustic-based proton range verification (protoacoustics) in water. Methods: Proton pulses with 17 µs FWHM and instantaneous currents of 480 nA (5.6 × 10{sup 7} protons/pulse, 8.9 cGy/pulse) were generated by a clinical, hospital-based cyclotron at the University of Pennsylvania. The protoacoustic signal generated in a water phantom by the 190 MeV proton pulses was measured with a hydrophone placed at multiple known positions surrounding the dose deposition. The background random noise was measured. The protoacoustic signal was simulated to compare to the experiments. Results: The maximum protoacoustic signal amplitude at 5more » cm distance was 5.2 mPa per 1 × 10{sup 7} protons (1.6 cGy at the Bragg peak). The background random noise of the measurement was 27 mPa. Comparison between simulation and experiment indicates that the hydrophone introduced a delay of 2.4 µs. For acoustic data collected with a signal-to-noise ratio (SNR) of 21, deconvolution of the protoacoustic signal with the proton pulse provided the most precise time-of-flight range measurement (standard deviation of 2.0 mm), but a systematic error (−4.5 mm) was observed. Conclusion: Based on water phantom measurements at a clinical hospital-based cyclotron, protoacoustics is a potential technique for measuring the proton Bragg peak range with 2.0 mm standard deviation. Simultaneous use of multiple detectors is expected to reduce the standard deviation, but calibration is required to remove systematic error. Based on the measured background noise and protoacoustic amplitude, a SNR of 5.3 is projected for a deposited dose of 2 Gy.« less
Isaksen, Jonas; Leber, Remo; Schmid, Ramun; Schmid, Hans-Jakob; Generali, Gianluca; Abächerli, Roger
2017-02-01
The first-order high-pass filter (AC coupling) has previously been shown to affect the ECG for higher cut-off frequencies. We seek to find a systematic deviation in computer measurements of the electrocardiogram when the AC coupling with a 0.05 Hz first-order high-pass filter is used. The standard 12-lead electrocardiogram from 1248 patients and the automated measurements of their DC and AC coupled version were used. We expect a large unipolar QRS-complex to produce a deviation in the opposite direction in the ST-segment. We found a strong correlation between the QRS integral and the offset throughout the ST-segment. The coefficient for J amplitude deviation was found to be -0.277 µV/(µV⋅s). Potential dangerous alterations to the diagnostically important ST-segment were found. Medical professionals and software developers for electrocardiogram interpretation programs should be aware of such high-pass filter effects since they could be misinterpreted as pathophysiology or some pathophysiology could be masked by these effects. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Ramirez, Daniel Perez; Whiteman, David N.; Veselovskii, Igor; Kolgotin, Alexei; Korenskiy, Michael; Alados-Arboledas, Lucas
2013-01-01
In this work we study the effects of systematic and random errors on the inversion of multiwavelength (MW) lidar data using the well-known regularization technique to obtain vertically resolved aerosol microphysical properties. The software implementation used here was developed at the Physics Instrumentation Center (PIC) in Troitsk (Russia) in conjunction with the NASA/Goddard Space Flight Center. Its applicability to Raman lidar systems based on backscattering measurements at three wavelengths (355, 532 and 1064 nm) and extinction measurements at two wavelengths (355 and 532 nm) has been demonstrated widely. The systematic error sensitivity is quantified by first determining the retrieved parameters for a given set of optical input data consistent with three different sets of aerosol physical parameters. Then each optical input is perturbed by varying amounts and the inversion is repeated. Using bimodal aerosol size distributions, we find a generally linear dependence of the retrieved errors in the microphysical properties on the induced systematic errors in the optical data. For the retrievals of effective radius, number/surface/volume concentrations and fine-mode radius and volume, we find that these results are not significantly affected by the range of the constraints used in inversions. But significant sensitivity was found to the allowed range of the imaginary part of the particle refractive index. Our results also indicate that there exists an additive property for the deviations induced by the biases present in the individual optical data. This property permits the results here to be used to predict deviations in retrieved parameters when multiple input optical data are biased simultaneously as well as to study the influence of random errors on the retrievals. The above results are applied to questions regarding lidar design, in particular for the spaceborne multiwavelength lidar under consideration for the upcoming ACE mission.
PTV margin determination in conformal SRT of intracranial lesions
Parker, Brent C.; Shiu, Almon S.; Maor, Moshe H.; Lang, Frederick F.; Liu, H. Helen; White, R. Allen; Antolak, John A.
2002-01-01
The planning target volume (PTV) includes the clinical target volume (CTV) to be irradiated and a margin to account for uncertainties in the treatment process. Uncertainties in miniature multileaf collimator (mMLC) leaf positioning, CT scanner spatial localization, CT‐MRI image fusion spatial localization, and Gill‐Thomas‐Cosman (GTC) relocatable head frame repositioning were quantified for the purpose of determining a minimum PTV margin that still delivers a satisfactory CTV dose. The measured uncertainties were then incorporated into a simple Monte Carlo calculation for evaluation of various margin and fraction combinations. Satisfactory CTV dosimetric criteria were selected to be a minimum CTV dose of 95% of the PTV dose and at least 95% of the CTV receiving 100% of the PTV dose. The measured uncertainties were assumed to be Gaussian distributions. Systematic errors were added linearly and random errors were added in quadrature assuming no correlation to arrive at the total combined error. The Monte Carlo simulation written for this work examined the distribution of cumulative dose volume histograms for a large patient population using various margin and fraction combinations to determine the smallest margin required to meet the established criteria. The program examined 5 and 30 fraction treatments, since those are the only fractionation schemes currently used at our institution. The fractionation schemes were evaluated using no margin, a margin of just the systematic component of the total uncertainty, and a margin of the systematic component plus one standard deviation of the total uncertainty. It was concluded that (i) a margin of the systematic error plus one standard deviation of the total uncertainty is the smallest PTV margin necessary to achieve the established CTV dose criteria, and (ii) it is necessary to determine the uncertainties introduced by the specific equipment and procedures used at each institution since the uncertainties may vary among locations. PACS number(s): 87.53.Kn, 87.53.Ly PMID:12132939
Bernard, A M; Burgot, J L
1981-12-01
The reversibility of the determination reaction is the most frequent cause of deviations from linearity of thermometric titration curves. Because of this, determination of the equivalence point by the tangent method is associated with a systematic error. The authors propose a relationship which connects this error quantitatively with the equilibrium constant. The relation, verified experimentally, is deduced from a mathematical study of the thermograms and could probably be generalized to apply to other linear methods of determination.
NASA Astrophysics Data System (ADS)
Jung, Jae Hong; Jung, Joo-Young; Bae, Sun Hyun; Moon, Seong Kwon; Cho, Kwang Hwan
2016-10-01
The purpose of this study was to compare patient setup deviations for different image-guided protocols (weekly vs. biweekly) that are used in TomoDirect three-dimensional conformal radiotherapy (TD-3DCRT) for whole-breast radiation therapy (WBRT). A total of 138 defined megavoltage computed tomography (MVCT) image sets from 46 breast cancer cases were divided into two groups based on the imaging acquisition times: weekly or biweekly. The mean error, three-dimensional setup displacement error (3D-error), systematic error (Σ), and random error (σ) were calculated for each group. The 3D-errors were 4.29 ± 1.11 mm and 5.02 ± 1.85 mm for the weekly and biweekly groups, respectively; the biweekly error was 14.6% higher than the weekly error. The systematic errors in the roll angle and the x, y, and z directions were 0.48°, 1.72 mm, 2.18 mm, and 1.85 mm for the weekly protocol and 0.21°, 1.24 mm, 1.39 mm, and 1.85 mm for the biweekly protocol. Random errors in the roll angle and the x, y, and z directions were 25.7%, 40.6%, 40.0%, and 40.8% higher in the biweekly group than in the weekly group. For the x, y, and z directions, the distributions of the treatment frequency at less than 5 mm were 98.6%, 91.3%, and 94.2% in the weekly group and 94.2%, 89.9%, and 82.6% in the biweekly group. Moreover, the roll angles with 0 - 1° were 79.7% and 89.9% in the weekly and the biweekly groups, respectively. Overall, the evaluation of setup deviations for the two protocols revealed no significant differences (p > 0.05). Reducing the frequency of MVCT imaging could have promising effects on imaging doses and machine times during treatment. However, the biweekly protocol was associated with increased random setup deviations in the treatment. We have demonstrated a biweekly protocol of TD-3DCRT for WBRT, and we anticipate that our method may provide an alternative approach for considering the uncertainties in the patient setup.
Shell model description of heavy nuclei and abnormal collective motions
NASA Astrophysics Data System (ADS)
Qi, Chong
2018-05-01
In this contribution I present systematic calculations on the spectroscopy and electromagnetic transition properties of intermediate-mass and heavy nuclei around 100Sn and 208Pb. We employed the large-scale configuration interaction shell model approach with realistic interactions. Those nuclei are the longest isotopic chains that can be studied by the nuclear shell model. I will show that the yrast spectra of Te isotopes show a vibrational-like equally spaced pattern but the few known E2 transitions show rotational-like behaviour. These kinds of abnormal collective behaviors cannot be reproduced by standard collective models and provide excellent background to study the competition of single-particle and various collective degrees of freedom. Moreover, the calculated B(E2) values for neutron-deficient and heavier Te isotopes show contrasting different behaviours along the yrast line, which may be related to the enhanced neutron-proton correlation when approaching N=50. The deviations between theory and experiment concerning the energies and E2 transition properties of low-lying 0+ and 2+ excited states and isomeric states in those nuclei may provide a constraint on our understanding of nuclear deformation and intruder configuration in that region.
Stevenson, Jim; Kreppner, Jana; Pimperton, Hannah; Worsfold, Sarah; Kennedy, Colin
2015-05-01
The aim of this study is to estimate the extent to which children and adolescents with hearing impairment (HI) show higher rates of emotional and behavioural difficulties compared to normally hearing children. Studies of emotional and behavioural difficulties in children and adolescents were traced from computerized systematic searches supplemented, where appropriate, by studies referenced in previous narrative reviews. Effect sizes (Hedges' g) were calculated for all studies. Meta-analyses were conducted on the weighted effect sizes obtained for studies adopting the Strength and Difficulties Questionnaire (SDQ) and on the unweighted effect sizes for non-SDQ studies. 33 non-SDQ studies were identified in which emotional and behavioural difficulties in children with HI could be compared to normally hearing children. The unweighted average g for these studies was 0.36. The meta-analysis of the 12 SDQ studies gave estimated effect sizes of 0.23 (95% CI 0.07, 0.40), 0.34 (95% CI 0.19, 0.49) and -0.01 (95% CI -0.32, 0.13) for Parent, Teacher and Self-ratings of Total Difficulties, respectively. The SDQ sub-scale showing consistent differences across raters between groups with HI and those with normal hearing was Peer Problems. Children and adolescents with HI have scores on emotional and behavioural difficulties measures about a quarter to a third of a standard deviation higher than hearing children. Children and adolescents with HI are in need of support to help their social relationships particularly with their peers.
Developmental Dyslexia, Neurolinguistic Theory and Deviations in Brain Morphology.
ERIC Educational Resources Information Center
Hynd, George W.; And Others
1991-01-01
Reviews computer tomography and magnetic resonance imaging studies examining deviations in brain morphology. Discusses methodological and technical issues. Concludes that dyslexics show variations in specific brain regions. Suggests that neuroimaging procedures appear to provide direct evidence supporting the importance of deviations in normal…
Seay, Joseph F.; Gregorczyk, Karen N.; Hasselquist, Leif
2016-01-01
Abstract Influences of load carriage and inclination on spatiotemporal parameters were examined during treadmill and overground walking. Ten soldiers walked on a treadmill and overground with three load conditions (00 kg, 20 kg, 40 kg) during level, uphill (6% grade) and downhill (-6% grade) inclinations at self-selected speed, which was constant across conditions. Mean values and standard deviations for double support percentage, stride length and a step rate were compared across conditions. Double support percentage increased with load and inclination change from uphill to level walking, with a 0.4% stance greater increase at the 20 kg condition compared to 00 kg. As inclination changed from uphill to downhill, the step rate increased more overground (4.3 ± 3.5 steps/min) than during treadmill walking (1.7 ± 2.3 steps/min). For the 40 kg condition, the standard deviations were larger than the 00 kg condition for both the step rate and double support percentage. There was no change between modes for step rate standard deviation. For overground compared to treadmill walking, standard deviation for stride length and double support percentage increased and decreased, respectively. Changes in the load of up to 40 kg, inclination of 6% grade away from the level (i.e., uphill or downhill) and mode (treadmill and overground) produced small, yet statistically significant changes in spatiotemporal parameters. Variability, as assessed by standard deviation, was not systematically lower during treadmill walking compared to overground walking. Due to the small magnitude of changes, treadmill walking appears to replicate the spatiotemporal parameters of overground walking. PMID:28149338
NASA Astrophysics Data System (ADS)
Gaunaa, Mac; Heinz, Joachim; Skrzypiński, Witold
2016-09-01
The crossflow principle is one of the key elements used in engineering models for prediction of the aerodynamic loads on wind turbine blades in standstill or blade installation situations, where the flow direction relative to the wind turbine blade has a component in the direction of the blade span direction. In the present work, the performance of the crossflow principle is assessed on the DTU 10MW reference blade using extensive 3D CFD calculations. Analysis of the computational results shows that there is only a relatively narrow region in which the crossflow principle describes the aerodynamic loading well. In some conditions the deviation of the predicted loadings can be quite significant, having a large influence on for instance the integral aerodynamic moments around the blade centre of mass; which is very important for single blade installation applications. The main features of these deviations, however, have a systematic behaviour on all force components, which in this paper is employed to formulate the first version of an engineering correction method to the crossflow principle applicable for wind turbine blades. The new correction model improves the agreement with CFD results for the key aerodynamic loads in crossflow situations. The general validity of this model for other blade shapes should be investigated in subsequent works.
Hilbert, Martin
2012-03-01
A single coherent framework is proposed to synthesize long-standing research on 8 seemingly unrelated cognitive decision-making biases. During the past 6 decades, hundreds of empirical studies have resulted in a variety of rules of thumb that specify how humans systematically deviate from what is normatively expected from their decisions. Several complementary generative mechanisms have been proposed to explain those cognitive biases. Here it is suggested that (at least) 8 of these empirically detected decision-making biases can be produced by simply assuming noisy deviations in the memory-based information processes that convert objective evidence (observations) into subjective estimates (decisions). An integrative framework is presented to show how similar noise-based mechanisms can lead to conservatism, the Bayesian likelihood bias, illusory correlations, biased self-other placement, subadditivity, exaggerated expectation, the confidence bias, and the hard-easy effect. Analytical tools from information theory are used to explore the nature and limitations that characterize such information processes for binary and multiary decision-making exercises. The ensuing synthesis offers formal mathematical definitions of the biases and their underlying generative mechanism, which permits a consolidated analysis of how they are related. This synthesis contributes to the larger goal of creating a coherent picture that explains the relations among the myriad of seemingly unrelated biases and their potential psychological generative mechanisms. Limitations and research questions are discussed.
NASA Astrophysics Data System (ADS)
Ma, Na Na; Zhang, Hai Fei; Yin, Peng; Bao, Xiao Jun; Zhang, Hong Fei
2017-08-01
Within the improved Weizsäcker-Skyrme (WS)-type nuclear mass formulas, we systematically calculated one-nucleon and two-nucleon separated energy, α-decay and β-decay energies, and the odd-even staggering (OES) of nuclear binding energies. As a result, the root-mean-square (rms) deviations of 2267 nuclei within the new improved WS-type mass formula are dropped from 493 to 167 keV, where 2267 nuclei are extracted from the atomic mass evaluation of 2012. Simultaneously, all the rms deviations of one-nucleon and two-nucleon separation energies and decay energies Qα,Qβ-,Qβ+, and QEC for more than 3000 nuclei are cut down by about 100-400 keV. Further, some basic physical observations of 988 boundary nuclei are predicted for providing reference to experiments. Finally, the overall neutron OESs and proton OESs have been systemically investigated and the residual error satisfies a normal distribution. The pairing gaps Δn and Δp of the isotopes of O, Ca, Ni, Zr, Sn, Gd, Qs, Pb, Pa, Ds and the isotonic magic chains of N =28 ,50 ,82 ,126 and even-even nuclei are also studied with dramatic improvements obtained. Especially, the rms of Δn and Δp in these nuclei have been reduced by about 200 keV. The above physical quantities show important information for nuclear charts and the features of nuclear structure.
NASA Astrophysics Data System (ADS)
Titov, O. A.; Lopez, Yu. R.
2018-03-01
We consider a method of reconstructing the structure delay of extended radio sources without constructing their radio images. The residuals derived after the adjustment of geodetic VLBI observations are used for this purpose. We show that the simplest model of a radio source consisting of two point components can be represented by four parameters (the angular separation of the components, the mutual orientation relative to the poleward direction, the flux-density ratio, and the spectral index difference) that are determined for each baseline of a multi-baseline VLBI network. The efficiency of this approach is demonstrated by estimating the coordinates of the radio source 0014+813 observed during the two-week CONT14 program organized by the International VLBI Service (IVS) in May 2014. Large systematic deviations have been detected in the residuals of the observations for the radio source 0014+813. The averaged characteristics of the radio structure of 0014+813 at a frequency of 8.4 GHz can be calculated from these deviations. Our modeling using four parameters has confirmed that the source consists of two components at an angular separation of 0.5 mas in the north-south direction. Using the structure delay when adjusting the CONT14 observations leads to a correction of the average declination estimate for the radio source 0014+813 by 0.070 mas.
Macedo Ribeiro, Ana Freire; Bergmann, Anke; Lemos, Thiago; Pacheco, Antônio Guilherme; Mello Russo, Maitê; Santos de Oliveira, Laura Alice; de Carvalho Rodrigues, Erika
The main objective of this study was to review the literature to identify reference values for angles and distances of body segments related to upright posture in healthy adult women with the Postural Assessment Software (PAS/SAPO). Electronic databases (BVS, PubMed, SciELO and Scopus) were assessed using the following descriptors: evaluation, posture, photogrammetry, physical therapy, postural alignment, postural assessment, and physiotherapy. Studies that performed postural evaluation in healthy adult women with PAS/SAPO and were published in English, Portuguese and Spanish, between the years 2005 and 2014 were included. Four studies met the inclusion criteria. Data from the included studies were grouped to establish the statistical descriptors (mean, variance, and standard deviation) of the body angles and distances. A total of 29 variables were assessed (10 in the anterior views, 16 in the lateral right and left views, and 3 in the posterior views), and its respective mean and standard deviation were calculated. Reference values for the anterior and posterior views showed no symmetry between the right and left sides of the body in the frontal plane. There were also small differences in the calculated reference values for the lateral view. The proposed reference values for quantitative evaluation of the upright posture in healthy adult women estimated in the present study using PAS/SAPO could guide future studies and help clinical practice. Copyright © 2017. Published by Elsevier Inc.
Grueber, Catherine E; Hogg, Carolyn J; Ivy, Jamie A; Belov, Katherine
2015-04-01
Maintaining genetic diversity is a crucial goal of intensive management of threatened species, particularly for those populations that act as sources for translocation or re-introduction programmes. Most captive genetic management is based on pedigrees and a neutral theory of inheritance, an assumption that may be violated by selective forces operating in captivity. Here, we explore the conservation consequences of early viability selection: differential offspring survival that occurs prior to management or research observations, such as embryo deaths in utero. If early viability selection produces genotypic deviations from Mendelian predictions, it may undermine management strategies intended to minimize inbreeding and maintain genetic diversity. We use empirical examples to demonstrate that straightforward approaches, such as comparing litter sizes of inbred vs. noninbred breeding pairs, can be used to test whether early viability selection likely impacts estimates of inbreeding depression. We also show that comparing multilocus genotype data to pedigree predictions can reveal whether early viability selection drives systematic biases in genetic diversity, patterns that would not be detected using pedigree-based statistics alone. More sophisticated analysis combining genomewide molecular data with pedigree information will enable conservation scientists to test whether early viability selection drives deviations from neutrality across wide stretches of the genome, revealing whether this form of selection biases the pedigree-based statistics and inference upon which intensive management is based. © 2015 John Wiley & Sons Ltd.
Kim, Kyung-Seon; Park, Soo-Byung; Kim, Seong-Sik; Kim, Yong-Il
2013-01-01
Objective In this study, we aimed to examine the relationship between chin deviation and the positional and morphological features of the mandible and to determine the factors that contributed to chin deviation in individuals with a unilateral cleft lip and palate (UCLP). Methods Cone-beam computed tomography (CBCT) images of 28 adults with UCLP were analyzed in this study. Segmented three-dimensional temporomandibular fossa and mandible images were reconstructed, and angular, linear, and volumetric parameters were measured. Results For all 28 individuals, the chin was found to deviate to the cleft side by 1.59 mm. Moreover, among these 28 individuals, only 7 showed distinct (more than 4 mm) chin deviation, which was toward the cleft side. Compared to the non-cleft side, the mandibular body length, frontal ramal inclination, and vertical position of the condyle were lower and inclination of the temporomandibular fossa was steeper on the cleft side. Furthermore, the differences in inclination of the temporomandibular fossa, mandibular body length, ramus length, and condylar volume ratio (non-deviated/deviated) were positively correlated with chin deviation. Conclusions UCLP individuals show mild chin deviation to the cleft side. Statistical differences were noted in the parameters that represented positional and morphological asymmetries of the mandible and temporomandibular fossa; however, these differences were too small to indicate clinical significance. PMID:24015386
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Bin; Pettitt, Bernard M.
Electrostatic free energies of solvation for 15 neutral amino acid side chain analogs are computed. We compare three methods of varying computational complexity and accuracy for three force fields: free energy simulations, Poisson-Boltzmann (PB), and linear response approximation (LRA) using AMBER, CHARMM, and OPLSAA force fields. We find that deviations from simulation start at low charges for solutes. The approximate PB and LRA produce an overestimation of electrostatic solvation free energies for most of molecules studied here. These deviations are remarkably systematic. The variations among force fields are almost as large as the variations found among methods. Our study confirmsmore » that success of the approximate methods for electrostatic solvation free energies comes from their ability to evaluate free energy differences accurately.« less
Cuppo, F L S; Gómez, S L; Figueiredo Neto, A M
2004-04-01
In this paper is reported a systematic experimental study of the linear-optical-absorption coefficient of ferrofluid-doped isotropic lyotropic mixtures as a function of the magnetic-grains concentration. The linear optical absorption of ferrolyomesophases increases in a nonlinear manner with the concentration of magnetic grains, deviating from the usual Beer-Lambert law. This behavior is associated to the presence of correlated micelles in the mixture which favors the formation of small-scale aggregates of magnetic grains (dimers), which have a higher absorption coefficient with respect to that of isolated grains. We propose that the indirect heating of the micelles via the ferrofluid grains (hyperthermia) could account for this nonlinear increase of the linear-optical-absorption coefficient as a function of the grains concentration.
Maeda, Yoshikazu; Sato, Yoshitaka; Shibata, Satoshi; Bou, Sayuri; Yamamoto, Kazutaka; Tamamura, Hiroyasu; Fuwa, Nobukazu; Takamatsu, Shigeyuki; Sasaki, Makoto; Tameshige, Yuji; Kume, Kyo; Minami, Hiroki; Saga, Yusuke; Saito, Makoto
2018-05-01
We quantified interfractional movements of the prostate, seminal vesicles (SVs), and rectum during computed tomography (CT) image-guided proton therapy for prostate cancer and studied the range variation in opposed lateral proton beams. We analyzed 375 sets of daily CT images acquired throughout the proton therapy treatment of ten patients. We analyzed daily movements of the prostate, SVs, and rectum by simulating three image-matching strategies: bone matching, prostate center (PC) matching, and prostate-rectum boundary (PRB) matching. In the PC matching, translational movements of the prostate center were corrected after bone matching. In the PRB matching, we performed PC matching and correction along the anterior-posterior direction to match the boundary between the prostate and the rectum's anterior region. In each strategy, we evaluated systematic errors (Σ) and random errors (σ) by measuring the daily movements of certain points on each anatomic structure. The average positional deviations in millimeter of each point were determined by the Van Herk formula of 2.5Σ + 0.7σ. Using these positional deviations, we created planning target volumes of the prostate and SVs and analyzed the daily variation in the water equivalent length (WEL) from the skin surface to the target along the lateral beam directions using the density converted from the daily CT number. Based on this analysis, we designed prostate cancer treatment planning and evaluated the dose volume histograms (DVHs) for these strategies. The SVs' daily movements showed large variations over the superior-inferior direction, as did the rectum's anterior region. The average positional deviations of the prostate in the anterior, posterior, superior, inferior, and lateral sides (mm) in bone matching, PC matching, and PRB matching were (8.9, 9.8, 7.5, 3.6, 1.6), (5.6, 6.1, 3.5, 4.5, 1.9), and (8.6, 3.2, 3.5, 4.5, 1.9) (mm), respectively. Moreover, the ones of the SV tip were similarly (22.5, 15.5, 11.0, 7.6, 6.0), (11.8, 8.4, 7.8, 5.2, 6.3), and (9.9, 7.5, 7.8, 5.2, 6.3). PRB matching showed the smallest positional deviations at all portions except for the anterior portion of the prostate and was able to markedly reduce the positional deviations at the posterior portion. The averaged WEL variations at the distal and proximal sides of planning target volumes were estimated 7-9 mm and 4-6 mm, respectively, and showed the increasing of a few millimeters in PC and PRB matching compared to bone matching. In the treatment planning simulation, the DVH values of the rectum in PRB matching were reduced compared to those obtained with other matching strategies. The positional deviations for the prostate on the posterior side and the SVs were smaller by PRB matching than the other strategies and effectively reduced the rectal dose. 3D dose calculations indicate that PRB matching with CT image guidance may do a better job relative to other positioning methods to effectively reduce the rectal complications. The WEL variation was quite large, and the appropriate margin (approx. 10 mm) must be adapted to the proton range in an initial planning to maintain the coverage of target volumes throughout entire treatment. © 2018 American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, H; Song, K; Chetty, I
Purpose: To determine the 6 degree of freedom systematic deviations between 2D/3D and CBCT image registration with various imaging setups and fusion algorithms on the Varian Edge Linac. Methods: An anthropomorphic head phantom with radio opaque targets embedded was scanned with CT slice thicknesses of 0.8, 1, 2, and 3mm. The 6 DOF systematic errors were assessed by comparing 2D/3D (kV/MV with CT) with 3D/3D (CBCT with CT) image registrations with different offset positions, similarity measures, image filters, and CBCT slice thicknesses (1 and 2 mm). The 2D/3D registration accuracy of 51 fractions for 26 cranial SRS patients was alsomore » evaluated by analyzing 2D/3D pre-treatment verification taken after 3D/3D image registrations. Results: The systematic deviations of 2D/3D image registration using kV- kV, MV-kV and MV-MV image pairs were within ±0.3mm and ±0.3° for translations and rotations with 95% confidence interval (CI) for a reference CT with 0.8 mm slice thickness. No significant difference (P>0.05) on target localization was observed between 0.8mm, 1mm, and 2mm CT slice thicknesses with CBCT slice thicknesses of 1mm and 2mm. With 3mm CT slice thickness, both 2D/3D and 3D/3D registrations performed less accurately in longitudinal direction than thinner CT slice thickness (0.60±0.12mm and 0.63±0.07mm off, respectively). Using content filter and using similarity measure of pattern intensity instead of mutual information, improved the 2D/3D registration accuracy significantly (P=0.02 and P=0.01, respectively). For the patient study, means and standard deviations of residual errors were 0.09±0.32mm, −0.22±0.51mm and −0.07±0.32mm in VRT, LNG and LAT directions, respectively, and 0.12°±0.46°, −0.12°±0.39° and 0.06°±0.28° in RTN, PITCH, and ROLL directions, respectively. 95% CI of translational and rotational deviations were comparable to those in phantom study. Conclusion: 2D/3D image registration provided on the Varian Edge radiosurgery, 6 DOF-based system provides accurate target positioning for frameless image-guided cranial stereotactic radiosurgery.« less
A Comparison of Observed Abundances in Five Well-Studied Planetary Nebulae
NASA Astrophysics Data System (ADS)
Tanner, Jolene; Balick, B.; Kwitter, K. B.
2013-01-01
We have assembled data and derived abundances in several recent careful studies for five bright planetary nebulae (PNe) of low, moderate, and high ionization and relatively simple morphology. Each of the studies employ different apertures, aperture placement, and facilities for the observations. Various methods were used to derive total abundances. All used spectral windows that included [OII]3727 in the UV through Argon lines in the red. Our ultimate goal is to determine the extent to which the derived abundances are consistent. We show that the reddening-corrected line ratios are surprisingly similar despite the different modes of observation and that the various abundance analysis methods yield generally consistent results for He/H, N/H, O/H, and Ne/H (within 50% with a few larger deviations). In addition we processed the line ratios from the different sources using a common abundance derivation method (ELSA) to search for clues of systematic methodological inconsistencies. None were uncovered.
Effects of vegetation canopy on the radar backscattering coefficient
NASA Technical Reports Server (NTRS)
Mo, T.; Blanchard, B. J.; Schmugge, T. J.
1983-01-01
Airborne L- and C-band scatterometer data, taken over both vegetation-covered and bare fields, were systematically analyzed and theoretically reproduced, using a recently developed model for calculating radar backscattering coefficients of rough soil surfaces. The results show that the model can reproduce the observed angular variations of radar backscattering coefficient quite well via a least-squares fit method. Best fits to the data provide estimates of the statistical properties of the surface roughness, which is characterized by two parameters: the standard deviation of surface height, and the surface correlation length. In addition, the processes of vegetation attenuation and volume scattering require two canopy parameters, the canopy optical thickness and a volume scattering factor. Canopy parameter values for individual vegetation types, including alfalfa, milo and corn, were also determined from the best-fit results. The uncertainties in the scatterometer data were also explored.
Todorović, Dejan
2008-01-01
Every image of a scene produced in accord with the rules of linear perspective has an associated projection centre. Only if observed from that position does the image provide the stimulus which is equivalent to the one provided by the original scene. According to the perspective-transformation hypothesis, observing the image from other vantage points should result in specific transformations of the structure of the conveyed scene, whereas according to the vantage-point compensation hypothesis it should have little effect. Geometrical analyses illustrating the transformation theory are presented. An experiment is reported to confront the two theories. The results provide little support for the compensation theory and are generally in accord with the transformation theory, but also show systematic deviations from it, possibly due to cue conflict and asymmetry of visual angles.
Temporal Structure of Volatility Fluctuations
NASA Astrophysics Data System (ADS)
Wang, Fengzhong; Yamasaki, Kazuko; Stanley, H. Eugene; Havlin, Shlomo
Volatility fluctuations are of great importance for the study of financial markets, and the temporal structure is an essential feature of fluctuations. To explore the temporal structure, we employ a new approach based on the return interval, which is defined as the time interval between two successive volatility values that are above a given threshold. We find that the distribution of the return intervals follows a scaling law over a wide range of thresholds, and over a broad range of sampling intervals. Moreover, this scaling law is universal for stocks of different countries, for commodities, for interest rates, and for currencies. However, further and more detailed analysis of the return intervals shows some systematic deviations from the scaling law. We also demonstrate a significant memory effect in the return intervals time organization. We find that the distribution of return intervals is strongly related to the correlations in the volatility.
Feasibility analysis of marine ecological on-line integrated monitoring system
NASA Astrophysics Data System (ADS)
Chu, D. Z.; Cao, X.; Zhang, S. W.; Wu, N.; Ma, R.; Zhang, L.; Cao, L.
2017-08-01
The in-situ water quality sensors were susceptible to biological attachment. Moreover, sea water corrosion and wave impact damage, and many sensors scattered distribution would cause maintenance inconvenience. The paper proposed a highly integrated marine ecological on-line integrated monitoring system, which can be used inside monitoring station. All sensors were reasonably classified, the similar in series, the overall in parallel. The system composition and workflow were described. In addition, the paper proposed attention issues of the system design and corresponding solutions. Water quality multi-parameters and 5 nutrient salts as the verification index, in-situ and systematic data comparison experiment were carried out. The results showed that the data consistency of nutrient salt, PH and salinity was better. Temperature and dissolved oxygen data trend was consistent, but the data had deviation. Turbidity fluctuated greatly; the chlorophyll trend was similar with it. Aiming at the above phenomena, three points system optimization direction were proposed.
Forest-fire model as a supercritical dynamic model in financial systems
NASA Astrophysics Data System (ADS)
Lee, Deokjae; Kim, Jae-Young; Lee, Jeho; Kahng, B.
2015-02-01
Recently large-scale cascading failures in complex systems have garnered substantial attention. Such extreme events have been treated as an integral part of self-organized criticality (SOC). Recent empirical work has suggested that some extreme events systematically deviate from the SOC paradigm, requiring a different theoretical framework. We shed additional theoretical light on this possibility by studying financial crisis. We build our model of financial crisis on the well-known forest fire model in scale-free networks. Our analysis shows a nontrivial scaling feature indicating supercritical behavior, which is independent of system size. Extreme events in the supercritical state result from bursting of a fat bubble, seeds of which are sown by a protracted period of a benign financial environment with few shocks. Our findings suggest that policymakers can control the magnitude of financial meltdowns by keeping the economy operating within reasonable duration of a benign environment.
Solar wind and coronal structure near sunspot minimum - Pioneer and SMM observations from 1985-1987
NASA Technical Reports Server (NTRS)
Mihalov, J. D.; Barnes, A.; Hundhausen, A. J.; Smith, E. J.
1990-01-01
Changes in solar wind speed and magnetic polarity observed at the Pioneer spacecraft are discussed here in terms of the changing magnetic geometry implied by SMM coronagraph observations over the period 1985-1987. The pattern of recurrent solar wind streams, the long-term average speed, and the sector polarity of the interplanetary magnetic field all changed in a manner suggesting both a temporal variation, and a changing dependence on heliographic latitude. Coronal observations during this epoch show a systematic variation in coronal structure and the magnetic structure imposed on the expanding solar wind. These observations suggest interpretation of the solar wind speed variations in terms of the familiar model where the speed increases with distance from a nearly flat interplanetary current sheet, and where this current sheet becomes aligned with the solar equatorial plane as sunspot minimum approaches, but deviates rapidly from that orientation after minimum.
The relationship between physical workload and quality within line-based assembly.
Ivarsson, Anna; Eek, Frida
2016-07-01
Reducing costs and improvement of product quality are considered important to ensure productivity within a company. Quality deviations during production processes and ergonomics have previously shown to be associated. This study explored the relationship between physical workload and real (found during production processes) and potential (need of extra time and assistance to complete tasks) quality deviations in a line-based assembly plant. The physical workload on and the work rotation between 52 workstations were assessed. As the outcome, real and potential quality deviations were studied during 10 weeks. Results show that workstations with higher physical workload had significantly more real deviations compared to lower workload stations. Static work posture had significantly more potential deviations. Rotation between high and low workload was related to fewer quality deviations compared to rotation between only high workload stations. In conclusion, physical ergonomics seems to be related to real and potential quality deviation within line-based assembly. Practitioner Summary: To ensure good productivity in manufacturing industries, it is important to reduce costs and improve product quality. This study shows that high physical workload is associated with quality deviations and need of extra time and assistance to complete tasks within line-based assembly, which can be financially expensive for a company.
Aerosol Optical Depth as Observed by the Mars Science Laboratory REMS UV Photodiodes
NASA Astrophysics Data System (ADS)
Smith, M. D.; Zorzano, M. P.; Lemmon, M. T.; Martín-Torres, J.; Mendaza de Cal, T.
2016-12-01
Systematic observations taken by the REMS UV photodiodes on a daily basis throughout the landed Mars Science Laboratory mission provide a highly useful tool for characterizing aerosols above Gale Crater. Radiative transfer modeling is used to model the more than two Mars Years of observations taken to date taking into account multiple scattering from aerosols and the extended field of view of the REMS UV photodiodes. The retrievals show in detail the annual cycle of aerosol optical depth, which is punctuated with numerous short timescale events of increased optical depth. Dust deposition onto the photodiodes is accounted for by comparison with aerosol optical depth derived from direct imaging of the Sun by Mastcam. The effect of dust on the photodiodes is noticeable, but does not dominate the signal. Cleaning of dust from the photodiodes was observed in the season around Ls=270°, but not during other seasons. Systematic deviations in the residuals from the retrieval fit are indicative of changes in aerosol effective particle size, with larger particles present during periods of increased optical depth. This seasonal dependence of aerosol particle size is expected as dust activity injects larger particles into the air, while larger aerosols settle out of the atmosphere more quickly leading to a smaller average particle size over time.
Aerosol optical depth as observed by the Mars Science Laboratory REMS UV photodiodes
NASA Astrophysics Data System (ADS)
Smith, Michael D.; Zorzano, María-Paz; Lemmon, Mark; Martín-Torres, Javier; Mendaza de Cal, Teresa
2016-12-01
Systematic observations taken by the REMS UV photodiodes on a daily basis throughout the landed Mars Science Laboratory mission provide a highly useful tool for characterizing aerosols above Gale Crater. Radiative transfer modeling is used to model the approximately 1.75 Mars Years of observations taken to date taking into account multiple scattering from aerosols and the extended field of view of the REMS UV photodiodes. The retrievals show in detail the annual cycle of aerosol optical depth, which is punctuated with numerous short timescale events of increased optical depth. Dust deposition onto the photodiodes is accounted for by comparison with aerosol optical depth derived from direct imaging of the Sun by Mastcam. The effect of dust on the photodiodes is noticeable, but does not dominate the signal. Cleaning of dust from the photodiodes was observed in the season around Ls=270°, but not during other seasons. Systematic deviations in the residuals from the retrieval fit are indicative of changes in aerosol effective particle size, with larger particles present during periods of increased optical depth. This seasonal dependence of aerosol particle size is expected as dust activity injects larger particles into the air, while larger aerosols settle out of the atmosphere more quickly leading to a smaller average particle size over time.
The impact of growth hormone therapy on adult height in noonan syndrome: a systematic review.
Giacomozzi, Claudio; Deodati, Annalisa; Shaikh, Mohamad Guftar; Ahmed, Syed Faisal; Cianfarani, Stefano
2015-01-01
Recombinant human growth hormone (rhGH) is being used to promote linear growth in short children with Noonan syndrome. However, its efficacy is still controversial. To systematically determine the impact of rhGH therapy on adult height in children with Noonan syndrome. We searched the Cochrane Central Register of Controlled Trials, ISI Web of Science, MEDLINE, and the bibliographic references from all retrieved articles published until April 2014. Studies reporting adult/near-adult height in children with Noonan syndrome treated with rhGH or reporting at least a 3-year follow-up were analysed. Quality and strength of recommendation were assessed according to the Endocrine Society criteria. No controlled trials reporting adult height were available. Five studies were identified reporting adult height or near adult height. Data comparison showed inter-individual variability in the response to rhGH, mean height gain standard deviation score ranging between 0.6 and 1.4 according to national standards, and between 0.6 and 2 according to Noonan standards. Significant biases affected all the studies. High-quality controlled trials on the impact of rhGH therapy on adult height are lacking, and the robustness of available data is not sufficient to recommend such therapy in children with Noonan syndrome. © 2015 S. Karger AG, Basel.
Rhenium-osmium systematics of calcium-aluminium-rich inclusions in carbonaceous chondrites
Becker, H.; Morgan, J.W.; Walker, R.J.; MacPherson, G.J.; Grossman, J.N.
2001-01-01
The Re-Os isotopic systematics of calcium-aluminium-rich inclusions (CAIs) in chondrites were investigated in order to shed light on the behavior of the Re-Os system in bulk chondrites, and to constrain the timing of chemical fractionation in primitive chondrites. CAIs with relatively unfractionated rare earth element (REE) patterns (groups I, III, V, VI) define a narrow range of 187Re/188Os (0.3764-0.4443) and 187Os/188Os (0.12599-0.12717), and high but variable Re and Os abundances (3209-41,820 ppb Os). In contrast, CAIs that show depletions in highly refractory elements and strongly fractionated REE patterns (group II) also show a much larger range in 187Re/188Os (0.409-0.535) and 187Os/188Os (0.12695-0.13770), and greater than an order of magnitude lower Re and Os abundances than other groups (e.g., 75.7-680.2 ppb Os). Sixteen bulk CAIs and CAI splits plot within analytical uncertainty of a 4558 Ga reference isochron, as is expected for materials of this antiquity. Eight samples, however, plot off the isochron. Several possible reasons for these deviations are discussed. Data for multiple splits of one CAI indicate that the nonisochronous behavior for at least this CAI is the result of Re-Os reequilibration at approximately 1.6 Ga. Thus, the most likely explanation for the deviations of most of the nonisochronous CAIs is late-stage open-system behavior of Re and Os in the asteroidal environment. The 187Os/188Os-Os systematics of CAIs are consistent with previous models that indicate group II CAIs are mixtures of components that lost the bulk of their highly refractory elements in a previous condensation event and a minor second component that provided refractory elements at chondritic relative proportions. The high Re/Os of group II CAIs relative to other CAIs and chondrite bulk rocks may have been caused by variable mobilization of Re and Os during medium- to low-temperature parent body alteration ??4.5 Ga ago. This model is favored over nebular models, which pose several difficulties. The narrow range of 187Os/188Os in group I, III, V, and VI bulk CAIs, and the agreement with 187Os/188Os of whole rock carbonaceous chondrites suggest that on a bulk inclusion scale, secondary alteration only modestly fractionated Re/Os in these CAIs. The average of 187Os/188Os for group I, III, V, and VI CAIs is indistinguishable from average CI chondrites, indicating a modern solar system value for 187Os/188Os of 0.12650, corresponding to a 187Re/188Os of 0.3964. Copyright ?? 2001 Elsevier Science Ltd.
Heparin Reversal After Cardiopulmonary Bypass: Are Point-of-Care Coagulation Tests Interchangeable?
Willems, Ariane; Savan, Veaceslav; Faraoni, David; De Ville, Andrée; Rozen, Laurence; Demulder, Anne; Van der Linden, Philippe
2016-10-01
Protamine is used to neutralize heparin after patient separation from cardiopulmonary bypass (CPB). Different bedside tests are used to monitor the adequacy of heparin neutralization. For this study, the interchangeability of the activated coagulation time (ACT) and thromboelastometry (ROTEM; Tem Innovations GmbH, Basel, Switzerland) clotting time (CT) ratios in children undergoing cardiac surgery was assessed. Single-center, retrospective, cohort study between September 2010 and January 2012. University children's hospital. The study comprised children 0 to 16 years old undergoing elective cardiac surgery with CPB. Exclusion criteria were preoperative coagulopathy, Jehovah's witnesses, and children in a moribund condition (American Society of Anesthesiologists score 5). None. After heparin neutralization with protamine, the ratio between ACT, with and without heparinase, and the CT measured with INTEM/HEPTEM (intrinsic test activated with ellagic acid was performed without heparinase [INTEM] and with heparinase [HEPTEM]) using tests of ROTEM were calculated. Agreement was evaluated using Cohen's kappa statistics, Passing-Bablok regression, and Bland-Altman analysis. Among the 173 patients included for analysis, agreement between both tests showed a Cohen's kappa statistic of 0.06 (95% CI: -0.02 to 0.14; p = 0.22). Bland-Altman analysis showed a bias of 0.01, with a standard deviation of 0.13, and limits of agreement between -0.24 and 0.26. Passing-Bablok regression showed a systematic difference of 0.40 (95% CI: 0.16-0.59) and a proportional difference of 0.61 (95% CI: 0.42-0.86). The residual standard deviation was 0.11 (95% CI: -0.22 to 0.22), and the test for linearity showed p = 0.10. ACT, with or without heparinase, and the INTEM/HEPTEM CT ratios are not interchangeable to evaluate heparin reversal after pediatric patient separation from CPB. Therefore, the results of these tests should be corroborated with the absence/presence of bleeding and integrated into center-specific treatment algorithms. Copyright © 2016 Elsevier Inc. All rights reserved.
Cosmic shear as a probe of galaxy formation physics
Foreman, Simon; Becker, Matthew R.; Wechsler, Risa H.
2016-09-01
Here, we evaluate the potential for current and future cosmic shear measurements from large galaxy surveys to constrain the impact of baryonic physics on the matter power spectrum. We do so using a model-independent parametrization that describes deviations of the matter power spectrum from the dark-matter-only case as a set of principal components that are localized in wavenumber and redshift. We perform forecasts for a variety of current and future data sets, and find that at least ~90 per cent of the constraining power of these data sets is contained in no more than nine principal components. The constraining powermore » of different surveys can be quantified using a figure of merit defined relative to currently available surveys. With this metric, we find that the final Dark Energy Survey data set (DES Y5) and the Hyper Suprime-Cam Survey will be roughly an order of magnitude more powerful than existing data in constraining baryonic effects. Upcoming Stage IV surveys (Large Synoptic Survey Telescope, Euclid, and Wide Field Infrared Survey Telescope) will improve upon this by a further factor of a few. We show that this conclusion is robust to marginalization over several key systematics. The ultimate power of cosmic shear to constrain galaxy formation is dependent on understanding systematics in the shear measurements at small (sub-arcminute) scales. Lastly, if these systematics can be sufficiently controlled, cosmic shear measurements from DES Y5 and other future surveys have the potential to provide a very clean probe of galaxy formation and to strongly constrain a wide range of predictions from modern hydrodynamical simulations.« less
Haghighatdoost, Fahimeh; Nobakht M Gh, B Fatemeh; Hariri, Mitra
2017-01-01
Our objective was to perform a systematic review and meta-analysis on randomized controlled trials (RCTs) assessing the effect of green tea on serum adiponectin concentration. We searched PubMed, ISI Web of Science, Scopus, and the Google Scholar databases up to November 2016. RCTs conducted among human adults studied the effects of green tea and green tea extract on serum adiponectin concentrations as an outcome variable was included. The weighted mean differences and standard deviations (SD) of change in serum adiponectin levels were calculated. The random effects model was used for deriving a summary of mean estimates with their corresponding SDs. The protocol was registered with PROSPERO (No. CRD42017057716). Fourteen RCTs were eligible to be included in the systematic review and the meta-analysis. Our analysis showed that green tea did not significantly affect adiponectin concentrations in comparison with placebo (weighted mean difference = -0.02 µg/ml, 95% confidence interval [CI], -0.41, 0.38; p = 0.936). There was a substantial heterogeneity between studies (I 2 = 91.7%; p < 0.0001). Subgroup analyses based on sex, type of intervention, continent, and body mass index (BMI) could not explain the sources of heterogeneity. Metaregression analyses revealed that the dose and duration of green tea ingestion did not have any effect on adiponectin concentrations. Green tea could not change the circulatory adiponectin levels. The dose and duration of green tea could not change the result. RCTs with longer follow-up periods and higher doses are needed to replicate our results.
Association of Omega-3 Fatty Acid and Epileptic Seizure in Epileptic Patients: A Systematic Review.
Pourmasoumi, Makan; Vosoughi, Nooshin; Derakhshandeh-Rishehri, Seyedeh-Masoumeh; Assarroudi, Mostafa; Heidari-Beni, Motahar
2018-01-01
The evidence on the association between omega-3 consumption and epileptic seizure is inconsistent. Therefore, we have conducted this systematic review to clarify the possible relationship. Original articles were searched in electronic databases (PubMed, Scopus, Google Scholar, Cochrane, and Ovid) and by reviewing the reference lists of retrieved articles. The main evaluated outcome was the epileptic seizures. We included the English language studies that reported the original data on the effect of omega-3 on epileptic human patients. We included the nine articles with 230 patients in the present systematic review. The mean ± standard deviation age of them was about 31.01 ± 14.99 years. The average of study duration was 22 ± 15.27 weeks. Omega-3 fatty acid supplements were defined as the sum of docosahexaenoic acid (DHA) and eicosapentaenoic acid (EPA) (1100 mg/d); as the sum of EPA, DHA, and alpha-linolenic acid (5 g/d); and as the sum of EPA alone (565 mg/d) in different studies. Among the nine studies, four studies reported a significant positive association between omega-3 fatty acids and epileptic seizures. However, power and quality of these studies are low, and we cannot consider the beneficial effect of omega-3 on seizures. In addition, five studies did not reveal any significant effect. Majority of the included studies did not show a significant association between omega-3 and epileptic seizure in epileptic patients, but further studies are necessary. It is controversial whether omega-3 fatty acids can produce positive effects on epileptic patients or not.
Elemental composition of solar energetic particles
NASA Technical Reports Server (NTRS)
Cook, W. R.; Stone, E. C.; Vogt, R. E.
1984-01-01
The Low Energy Telescopes on the Voyager spacecraft have been used to measure the elemental composition (Z = 2-28) and energy spectra (5-15 MeV per nucleon) of solar energetic particles (SEPs) in seven large flare events. Four flare events were selected which have SEP abundance ratios approximately independent of energy per nucleon. For these selected flare events, SEP composition results may be described by an average composition plus a systematic flare-to-flare deviation about the average. The four-flare average SEP composition is systematically different from the solar composition determined by photospheric spectroscopy. These systematic composition differences are apparently not due to SEP propagation or acceleration effects. In contrast, the four-flare average SEP composition is in agreement with measured solar wind abundances and with a number of recent spectroscopic coronal abundance measurements. These findings suggest that SEPs originate in the corona, and that both SEPs and the solar wind sample a coronal composition which is significantly and persistently different from that measured for the photosphere.
NASA Astrophysics Data System (ADS)
Liu, Zhixiang; Xing, Tingwen; Jiang, Yadong; Lv, Baobin
2018-02-01
A two-dimensional (2-D) shearing interferometer based on an amplitude chessboard grating was designed to measure the wavefront aberration of a high numerical-aperture (NA) objective. Chessboard gratings offer better diffraction efficiencies and fewer disturbing diffraction orders than traditional cross gratings. The wavefront aberration of the tested objective was retrieved from the shearing interferogram using the Fourier transform and differential Zernike polynomial-fitting methods. Grating manufacturing errors, including the duty-cycle and pattern-deviation errors, were analyzed with the Fourier transform method. Then, according to the relation between the spherical pupil and planar detector coordinates, the influence of the distortion of the pupil coordinates was simulated. Finally, the systematic error attributable to grating alignment errors was deduced through the geometrical ray-tracing method. Experimental results indicate that the measuring repeatability (3σ) of the wavefront aberration of an objective with NA 0.4 was 3.4 mλ. The systematic-error results were consistent with previous analyses. Thus, the correct wavefront aberration can be obtained after calibration.
NASA Astrophysics Data System (ADS)
Bundesmann, Carsten; Lautenschläge, Thomas; Spemann, Daniel; Finzel, Annemarie; Mensing, Michael; Frost, Frank
2017-10-01
The correlation between process parameters and properties of TiO2 films grown by ion beam sputter deposition from a ceramic target was investigated. TiO2 films were grown under systematic variation of ion beam parameters (ion species, ion energy) and geometrical parameters (ion incidence angle, polar emission angle) and characterized with respect to film thickness, growth rate, structural properties, surface topography, composition, optical properties, and mass density. Systematic variations of film properties with the scattering geometry, namely the scattering angle, have been revealed. There are also considerable differences in film properties when changing the process gas from Ar to Xe. Similar systematics were reported for TiO2 films grown by reactive ion beam sputter deposition from a metal target [C. Bundesmann et al., Appl. Surf. Sci. 421, 331 (2017)]. However, there are some deviations from the previously reported data, for instance, in growth rate, mass density and optical properties.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johannsen, Tim; Psaltis, Dimitrios
According to the no-hair theorem, astrophysical black holes are fully characterized by their masses and spins and are described by the Kerr metric. This theorem can be tested observationally by measuring (at least) three different multipole moments of the spacetimes of black holes. In this paper, we calculate the profiles of fluorescent iron lines emitted from the accretion flows around black hole candidates within a framework that allows us to perform the calculation as a function of its mass and spin as well as of a free parameter that measures potential deviations from the Kerr metric. We show that suchmore » deviations lead to line profiles that are significantly altered and may exhibit a modified flux ratio of the two peaks in their characteristic double-peaked shape. We also show that the disk inclination can be measured independently of the spin and the deviation parameter at low to intermediate inclination angles, as in the case of Kerr black holes. We estimate the precision that near-future X-ray missions such as Astro-H and ATHENA+ are required to achieve in order to resolve deviations from the Kerr metric in iron line profiles and show that constraints on such deviations will be strongest for rapidly spinning black holes. More generally, we show that measuring the line profile with a precision of {approx}5% at disk inclinations of 30 Degree-Sign or 60 Degree-Sign constrains the deviation parameter to order unity for values of the spin a {approx}> 0.5M.« less
Kolakovic, Mirela; Held, Ulrike; Schmidlin, Patrick R; Sahrmann, Philipp
2014-12-22
Relevant benefits of adjunctive medication of antibiotica after conventional root surface debridement in terms of enhanced pocket depth (PD) reduction have been shown. However, means and standard deviations of enhanced reductions are difficult to translate into clinical relevant treatment outcomes such as pocket resolution or avoidance of additional surgical interventions. Accordingly, the aim of this systematic review was to calculate odds ratios for relevant cut-off values of PD after mechanical periodontal treatment with and without antibiotics, specifically the combination of amoxicilline and metronidazol, from published studies. As clinical relevant cut-off values "pocket closure" for PD ≤ 3mm and "avoidance of surgical intervention" for PD ≤ 5 mm were determined. The databases PubMed, Embase and Central were searched for randomized clinical studies assessing the beneficial effect of the combination of amoxicillin and metronidazole after non-surgical mechanical debridement. Titles, abstracts and finally full texts were scrutinized for possible inclusion by two independent investigators. Quality and heterogeneity of the studies were assessed and the study designs were examined. From published means and standard deviations for PD after therapy, odds ratios for the clinically relevant cut-off values were calculated using a specific statistical approach. Meta-analyses were performed for the time points 3 and 6 month after mechanical therapy. Generally, a pronounced chance for pocket closure from 3 to 6 months of healing was shown. The administration of antibiotics resulted in a 3.55 and 4.43 fold higher probability of pocket closure after 3 and 6 months as compared to mechanical therapy alone. However, as the estimated risk for residual pockets > 5 mm was 0 for both groups, no odds ratio could be calculated for persistent needs for surgery. Generally, studies showed a moderate to high quality and large heterogeneity regarding treatment protocol, dose of antibiotic medication and maintenance. With the performed statistical approach, a clear benefit in terms of an enhanced chance for pocket closure by co-administration of the combination of amoxicillin and metronidazole as an adjunct to non-surgical mechanical periodontal therapy has been shown. However, data calculation failed to show a benefit regarding the possible avoidance of surgical interventions.
Christophe, Laure; Chabanat, Eric; Delporte, Ludovic; Revol, Patrice; Volckmann, Pierre; Jacquin-Courtois, Sophie; Rossetti, Yves
Complex Regional Pain Syndrome (CRPS) is an invalidating chronic condition subsequent to peripheral lesions. There is growing consensus for a central contribution to CRPS. However, the nature of this central body representation disorder is increasingly debated. Although it has been repeatedly argued that CRPS results in motor neglect of the affected side, visual egocentric reference frame was found to be deviated toward the pain, that is, neglect of the healthy side. Accordingly, prism adaptation has been successfully used to normalize this deviation. This study aimed at clarifying whether 7 CRPS patients exhibited neglect as well as exploring the pathophysiological mechanisms of this manifestation and of the therapeutic effects of prism adaptation. Pain and quality of life, egocentric reference frames (visual and proprioceptive straight-ahead), and neglect tests (line bisection, kinematic analyses of motor neglect and motor extinction) were repeatedly assessed prior to, during, and following a one-week intense prism adaptation intervention. First, our results provide no support for visual and motor neglect in CRPS. Second, reference frames for body representations were not systematically deviated. Third, intensive prism adaptation intervention durably ameliorated pain and quality of life. As for spatial neglect, understanding the therapeutic effects of prism adaptation deserves further investigations.
Evaluation of methods for measuring particulate matter emissions from gas turbines.
Petzold, Andreas; Marsh, Richard; Johnson, Mark; Miller, Michael; Sevcenco, Yura; Delhaye, David; Ibrahim, Amir; Williams, Paul; Bauer, Heidi; Crayford, Andrew; Bachalo, William D; Raper, David
2011-04-15
The project SAMPLE evaluated methods for measuring particle properties in the exhaust of aircraft engines with respect to the development of standardized operation procedures for particulate matter measurement in aviation industry. Filter-based off-line mass methods included gravimetry and chemical analysis of carbonaceous species by combustion methods. Online mass methods were based on light absorption measurement or used size distribution measurements obtained from an electrical mobility analyzer approach. Number concentrations were determined using different condensation particle counters (CPC). Total mass from filter-based methods balanced gravimetric mass within 8% error. Carbonaceous matter accounted for 70% of gravimetric mass while the remaining 30% were attributed to hydrated sulfate and noncarbonaceous organic matter fractions. Online methods were closely correlated over the entire range of emission levels studied in the tests. Elemental carbon from combustion methods and black carbon from optical methods deviated by maximum 5% with respect to mass for low to medium emission levels, whereas for high emission levels a systematic deviation between online methods and filter based methods was found which is attributed to sampling effects. CPC based instruments proved highly reproducible for number concentration measurements with a maximum interinstrument standard deviation of 7.5%.
Santana, Juan A.; Krogel, Jaron T.; Kent, Paul R. C.; ...
2016-05-03
We have applied the diffusion quantum Monte Carlo (DMC) method to calculate the cohesive energy and the structural parameters of the binary oxides CaO, SrO, BaO, Sc 2O 3, Y 2O 3 and La 2O 3. The aim of our calculations is to systematically quantify the accuracy of the DMC method to study this type of metal oxides. The DMC results were compared with local and semi-local Density Functional Theory (DFT) approximations as well as with experimental measurements. The DMC method yields cohesive energies for these oxides with a mean absolute deviation from experimental measurements of 0.18(2) eV, while withmore » local and semi-local DFT approximations the deviation is 3.06 and 0.94 eV, respectively. For lattice constants, the mean absolute deviation in DMC, local and semi-local DFT approximations, are 0.017(1), 0.07 and 0.05 , respectively. In conclusion, DMC is highly accurate method, outperforming the local and semi-local DFT approximations in describing the cohesive energies and structural parameters of these binary oxides.« less
Deviation-based spam-filtering method via stochastic approach
NASA Astrophysics Data System (ADS)
Lee, Daekyung; Lee, Mi Jin; Kim, Beom Jun
2018-03-01
In the presence of a huge number of possible purchase choices, ranks or ratings of items by others often play very important roles for a buyer to make a final purchase decision. Perfectly objective rating is an impossible task to achieve, and we often use an average rating built on how previous buyers estimated the quality of the product. The problem of using a simple average rating is that it can easily be polluted by careless users whose evaluation of products cannot be trusted, and by malicious spammers who try to bias the rating result on purpose. In this letter we suggest how trustworthiness of individual users can be systematically and quantitatively reflected to build a more reliable rating system. We compute the suitably defined reliability of each user based on the user's rating pattern for all products she evaluated. We call our proposed method as the deviation-based ranking, since the statistical significance of each user's rating pattern with respect to the average rating pattern is the key ingredient. We find that our deviation-based ranking method outperforms existing methods in filtering out careless random evaluators as well as malicious spammers.
NASA Astrophysics Data System (ADS)
Scharnagl, Benedikt; Durner, Wolfgang
2013-04-01
Models are inherently imperfect because they simplify processes that are themselves imperfectly known and understood. Moreover, the input variables and parameters needed to run a model are typically subject to various sources of error. As a consequence of these imperfections, model predictions will always deviate from corresponding observations. In most applications in soil hydrology, these deviations are clearly not random but rather show a systematic structure. From a statistical point of view, this systematic mismatch may be a reason for concern because it violates one of the basic assumptions made in inverse parameter estimation: the assumption of independence of the residuals. But what are the consequences of simply ignoring the autocorrelation in the residuals, as it is current practice in soil hydrology? Are the parameter estimates still valid even though the statistical foundation they are based on is partially collapsed? Theory and practical experience from other fields of science have shown that violation of the independence assumption will result in overconfident uncertainty bounds and that in some cases it may lead to significantly different optimal parameter values. In our contribution, we present three soil hydrological case studies, in which the effect of autocorrelated residuals on the estimated parameters was investigated in detail. We explicitly accounted for autocorrelated residuals using a formal likelihood function that incorporates an autoregressive model. The inverse problem was posed in a Bayesian framework, and the posterior probability density function of the parameters was estimated using Markov chain Monte Carlo simulation. In contrast to many other studies in related fields of science, and quite surprisingly, we found that the first-order autoregressive model, often abbreviated as AR(1), did not work well in the soil hydrological setting. We showed that a second-order autoregressive, or AR(2), model performs much better in these applications, leading to parameter and uncertainty estimates that satisfy all the underlying statistical assumptions. For theoretical reasons, these estimates are deemed more reliable than those estimates based on the neglect of autocorrelation in the residuals. In compliance with theory and results reported in the literature, our results showed that parameter uncertainty bounds were substantially wider if autocorrelation in the residuals was explicitly accounted for, and also the optimal parameter vales were slightly different in this case. We argue that the autoregressive model presented here should be used as a matter of routine in inverse modeling of soil hydrological processes.
Linear maps preserving maximal deviation and the Jordan structure of quantum systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamhalter, Jan
2012-12-15
In the algebraic approach to quantum theory, a quantum observable is given by an element of a Jordan algebra and a state of the system is modelled by a normalized positive functional on the underlying algebra. Maximal deviation of a quantum observable is the largest statistical deviation one can obtain in a particular state of the system. The main result of the paper shows that each linear bijective transformation between JBW algebras preserving maximal deviations is formed by a Jordan isomorphism or a minus Jordan isomorphism perturbed by a linear functional multiple of an identity. It shows that only onemore » numerical statistical characteristic has the power to determine the Jordan algebraic structure completely. As a consequence, we obtain that only very special maps can preserve the diameter of the spectra of elements. Nonlinear maps preserving the pseudometric given by maximal deviation are also described. The results generalize hitherto known theorems on preservers of maximal deviation in the case of self-adjoint parts of von Neumann algebras proved by Molnar.« less
Isoscalar-isovector mass splittings in excited mesons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geiger, P.
1994-06-01
Mass splittings between the isovector and isoscalar members of meson nonets arise in part from hadronic loop diagrams which violate the Okubo-Zweig-Iizuka rule. Using a model for these loop processes which works qualitatively well in the established nonets, I tabulate predictions for the splittings and associated isoscalar mixing angles in the remaining nonets below about 2 GeV, and explain some of their systematic features. The model predicts significant deviations from ideal mixing in the excited vector nonets.
Effect of patient setup errors on simultaneously integrated boost head and neck IMRT treatment plans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siebers, Jeffrey V.; Keall, Paul J.; Wu Qiuwen
2005-10-01
Purpose: The purpose of this study is to determine dose delivery errors that could result from random and systematic setup errors for head-and-neck patients treated using the simultaneous integrated boost (SIB)-intensity-modulated radiation therapy (IMRT) technique. Methods and Materials: Twenty-four patients who participated in an intramural Phase I/II parotid-sparing IMRT dose-escalation protocol using the SIB treatment technique had their dose distributions reevaluated to assess the impact of random and systematic setup errors. The dosimetric effect of random setup error was simulated by convolving the two-dimensional fluence distribution of each beam with the random setup error probability density distribution. Random setup errorsmore » of {sigma} = 1, 3, and 5 mm were simulated. Systematic setup errors were simulated by randomly shifting the patient isocenter along each of the three Cartesian axes, with each shift selected from a normal distribution. Systematic setup error distributions with {sigma} = 1.5 and 3.0 mm along each axis were simulated. Combined systematic and random setup errors were simulated for {sigma} = {sigma} = 1.5 and 3.0 mm along each axis. For each dose calculation, the gross tumor volume (GTV) received by 98% of the volume (D{sub 98}), clinical target volume (CTV) D{sub 90}, nodes D{sub 90}, cord D{sub 2}, and parotid D{sub 50} and parotid mean dose were evaluated with respect to the plan used for treatment for the structure dose and for an effective planning target volume (PTV) with a 3-mm margin. Results: Simultaneous integrated boost-IMRT head-and-neck treatment plans were found to be less sensitive to random setup errors than to systematic setup errors. For random-only errors, errors exceeded 3% only when the random setup error {sigma} exceeded 3 mm. Simulated systematic setup errors with {sigma} = 1.5 mm resulted in approximately 10% of plan having more than a 3% dose error, whereas a {sigma} = 3.0 mm resulted in half of the plans having more than a 3% dose error and 28% with a 5% dose error. Combined random and systematic dose errors with {sigma} = {sigma} = 3.0 mm resulted in more than 50% of plans having at least a 3% dose error and 38% of the plans having at least a 5% dose error. Evaluation with respect to a 3-mm expanded PTV reduced the observed dose deviations greater than 5% for the {sigma} = {sigma} = 3.0 mm simulations to 5.4% of the plans simulated. Conclusions: Head-and-neck SIB-IMRT dosimetric accuracy would benefit from methods to reduce patient systematic setup errors. When GTV, CTV, or nodal volumes are used for dose evaluation, plans simulated including the effects of random and systematic errors deviate substantially from the nominal plan. The use of PTVs for dose evaluation in the nominal plan improves agreement with evaluated GTV, CTV, and nodal dose values under simulated setup errors. PTV concepts should be used for SIB-IMRT head-and-neck squamous cell carcinoma patients, although the size of the margins may be less than those used with three-dimensional conformal radiation therapy.« less
NASA Astrophysics Data System (ADS)
Slanina, J.; Möls, J. J.; Baard, J. H.
The results of a wet deposition monitoring experiment, carried out by eight identical wet-only precipitation samplers operating on the basis of 24 h samples, have been used to investigate the accuracy and uncertainties in wet deposition measurements. The experiment was conducted near Lelystad, The Netherlands over the period 1 March 1983-31 December 1985. By rearranging the data for one to eight samplers and sampling periods of 1 day to 1 month both systematic and random errors were investigated as a function of measuring strategy. A Gaussian distribution of the results was observed. Outliers, detected by a Dixon test ( a = 0.05) influenced strongly both the yearly averaged results and the standard deviation of this average as a function of the number of samplers and the length of the sampling period. The systematic bias in bulk elements, using one sampler, varies typically from 2 to 20% and for trace elements from 10 to 500%, respectively. Severe problems are encountered in the case of Zn, Cu, Cr, Ni and especially Cd. For the sensitive detection of trends generally more than one sampler per measuring station is necessary as the standard deviation in the yearly averaged wet deposition is typically 10-20% relative for one sampler. Using three identical samplers, trends of, e.g. 3% per year will be generally detected in 6 years.
Visuospatial biases in preschool children: Evidence from line bisection in three-dimensional space.
Patro, Katarzyna; Nuerk, Hans-Christoph; Brugger, Peter
2018-04-09
Spatial attention in adults is characterized by systematic asymmetries across all three spatial dimensions. These asymmetries are evident when participants bisect horizontal, vertical, or radial lines and misplace their midpoints to the left, the top, or far from the body, respectively. However, bisection errors are rarely examined during early childhood. In this study, we examined the development of spatial-attentional asymmetries in three-dimensional (3D) space by asking preschool children (aged 3-6 years) to bisect horizontal, vertical, and radial lines. Children erred to the left with horizontal lines and to the top with vertical lines, consistent with the pattern reported in adults. These biases got stronger with age and were absent in the youngest preschoolers. However, by controlling for a possible failure in hitting the line, we observed an additional unpredicted pattern: Children's pointing systematically deviated away from the line to an empty space on its left side (for vertical and radial lines) or above it (for horizontal lines). Notably, this task-irrelevant deviation was pronounced in children as young as 3 or 4 years. We conclude that asymmetries in spatial-attentional functions should be measured not only in task-relevant dimensions but also in task-irrelevant dimensions because the latter may reveal biases in very young children not typically observed in task-relevant measures. Copyright © 2018 Elsevier Inc. All rights reserved.
Quantifying the Precision of Single-Molecule Torque and Twist Measurements Using Allan Variance.
van Oene, Maarten M; Ha, Seungkyu; Jager, Tessa; Lee, Mina; Pedaci, Francesco; Lipfert, Jan; Dekker, Nynke H
2018-04-24
Single-molecule manipulation techniques have provided unprecedented insights into the structure, function, interactions, and mechanical properties of biological macromolecules. Recently, the single-molecule toolbox has been expanded by techniques that enable measurements of rotation and torque, such as the optical torque wrench (OTW) and several different implementations of magnetic (torque) tweezers. Although systematic analyses of the position and force precision of single-molecule techniques have attracted considerable attention, their angle and torque precision have been treated in much less detail. Here, we propose Allan deviation as a tool to systematically quantitate angle and torque precision in single-molecule measurements. We apply the Allan variance method to experimental data from our implementations of (electro)magnetic torque tweezers and an OTW and find that both approaches can achieve a torque precision better than 1 pN · nm. The OTW, capable of measuring torque on (sub)millisecond timescales, provides the best torque precision for measurement times ≲10 s, after which drift becomes a limiting factor. For longer measurement times, magnetic torque tweezers with their superior stability provide the best torque precision. Use of the Allan deviation enables critical assessments of the torque precision as a function of measurement time across different measurement modalities and provides a tool to optimize measurement protocols for a given instrument and application. Copyright © 2018 Biophysical Society. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, H; Chetty, I; Wen, N
Purpose: Determine systematic deviations between 2D/3D and 3D/3D image registrations with six degrees of freedom (6DOF) for various imaging modalities and registration algorithms on the Varian Edge Linac. Methods: The 6DOF systematic errors were assessed by comparing automated 2D/3D (kV/MV vs. CT) with 3D/3D (CBCT vs. CT) image registrations from different imaging pairs, CT slice thicknesses, couch angles, similarity measures, etc., using a Rando head and a pelvic phantom. The 2D/3D image registration accuracy was evaluated at different treatment sites (intra-cranial and extra-cranial) by statistically analyzing 2D/3D pre-treatment verification against 3D/3D localization of 192 Stereotactic Radiosurgery/Stereotactic Body Radiation Therapy treatmentmore » fractions for 88 patients. Results: The systematic errors of 2D/3D image registration using kV-kV, MV-kV and MV-MV image pairs using 0.8 mm slice thickness CT images were within 0.3 mm and 0.3° for translations and rotations with a 95% confidence interval (CI). No significant difference between 2D/3D and 3D/3D image registrations (P>0.05) was observed for target localization at various CT slice thicknesses ranging from 0.8 to 3 mm. Couch angles (30, 45, 60 degree) did not impact the accuracy of 2D/3D image registration. Using pattern intensity with content image filtering was recommended for 2D/3D image registration to achieve the best accuracy. For the patient study, translational error was within 2 mm and rotational error was within 0.6 degrees in terms of 95% CI for 2D/3D image registration. For intra-cranial sites, means and std. deviations of translational errors were −0.2±0.7, 0.04±0.5, 0.1±0.4 mm for LNG, LAT, VRT directions, respectively. For extra-cranial sites, means and std. deviations of translational errors were - 0.04±1, 0.2±1, 0.1±1 mm for LNG, LAT, VRT directions, respectively. 2D/3D image registration uncertainties for intra-cranial and extra-cranial sites were comparable. Conclusion: The Varian Edge radiosurgery 6DOF-based system, can perform 2D/3D image registration with high accuracy for target localization in image-guided stereotactic radiosurgery. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.« less
Return Intervals Approach to Financial Fluctuations
NASA Astrophysics Data System (ADS)
Wang, Fengzhong; Yamasaki, Kazuko; Havlin, Shlomo; Stanley, H. Eugene
Financial fluctuations play a key role for financial markets studies. A new approach focusing on properties of return intervals can help to get better understanding of the fluctuations. A return interval is defined as the time between two successive volatilities above a given threshold. We review recent studies and analyze the 1000 most traded stocks in the US stock markets. We find that the distribution of the return intervals has a well approximated scaling over a wide range of thresholds. The scaling is also valid for various time windows from one minute up to one trading day. Moreover, these results are universal for stocks of different countries, commodities, interest rates as well as currencies. Further analysis shows some systematic deviations from a scaling law, which are due to the nonlinear correlations in the volatility sequence. We also examine the memory in return intervals for different time scales, which are related to the long-term correlations in the volatility. Furthermore, we test two popular models, FIGARCH and fractional Brownian motion (fBm). Both models can catch the memory effect but only fBm shows a good scaling in the return interval distribution.
The Effect of Microphone Type on Acoustical Measures of Synthesized Vowels.
Kisenwether, Jessica Sofranko; Sataloff, Robert T
2015-09-01
The purpose of this study was to compare microphones of different directionality, transducer type, and cost, with attention to their effects on acoustical measurements of period perturbation, amplitude perturbation, and noise using synthesized sustained vowel samples. This was a repeated measures design. Synthesized sustained vowel stimuli (with known acoustic characteristics and systematic changes in jitter, shimmer, and noise-to-harmonics ratio) were recorded by a variety of dynamic and condenser microphones. Files were then analyzed for mean fundamental frequency (fo), fo standard deviation, absolute jitter, shimmer in dB, peak-to-peak amplitude variation, and noise-to-harmonics ratio. Acoustical measures following recording were compared with the synthesized, known acoustical measures before recording. Although informal analyses showed some differences among microphones, and analyses of variance showed that type of microphone is a significant predictor, t-tests revealed that none of the microphones generated different means compared with the generated acoustical measures. In this sample, microphone type, directionality, and cost did not have a significant effect on the validity of acoustic measures. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Turbulence as a Problem in Non-equilibrium Statistical Mechanics
NASA Astrophysics Data System (ADS)
Goldenfeld, Nigel; Shih, Hong-Yan
2017-05-01
The transitional and well-developed regimes of turbulent shear flows exhibit a variety of remarkable scaling laws that are only now beginning to be systematically studied and understood. In the first part of this article, we summarize recent progress in understanding the friction factor of turbulent flows in rough pipes and quasi-two-dimensional soap films, showing how the data obey a two-parameter scaling law known as roughness-induced criticality, and exhibit power-law scaling of friction factor with Reynolds number that depends on the precise form of the nature of the turbulent cascade. These results hint at a non-equilibrium fluctuation-dissipation relation that applies to turbulent flows. The second part of this article concerns the lifetime statistics in smooth pipes around the transition, showing how the remarkable super-exponential scaling with Reynolds number reflects deep connections between large deviation theory, extreme value statistics, directed percolation and the onset of coexistence in predator-prey ecosystems. Both these phenomena reflect the way in which turbulence can be fruitfully approached as a problem in non-equilibrium statistical mechanics.
NASA Technical Reports Server (NTRS)
Beutter, B. R.; Mulligan, J. B.; Stone, L. S.; Statler, Irving C. (Technical Monitor)
1994-01-01
Mulligan showed that the perceived direction of a moving grating can be biased by the shape of the Gaussian window in which it is viewed. We sought to determine if a 2-D pattern with an unambiguous velocity would also show such biases. Observers viewed a drifting plaid (sum of two orthogonal 2.5 c/d sinusoidal gratings of 12% contrast, each with a TF of 4 Hz.) whose contrast was modulated spatially by a stationary, asymmetric 2-D Gaussian window (i.e. unequal standard deviations in the principal directions). The direction of plaid motion with respect to the orientation of the window's major axis (Delta Theta) was varied while all other motion parameters were held fixed. Observers reported the perceived plaid direction of motion by adjusting the orientation of a pointer. All five observers showed systematic biases in perceived plaid direction that depended on Delta Theta and the aspect ratio of the Gaussian window (lambda). For circular Gaussian windows Lambda = 1), plaid direction was veridically perceived. However, biases of up to 10 deg. were found for lambda = 2 and Delta Theta = 30 deg. These data present a challenge to models of motion perception which do not explicitly consider the integration of information across the visual field.
Bondarkov, Mikhail D; Zheltonozhsky, Viktor A; Zheltonozhskaya, Maryna V; Kulich, Nadezhda V; Maksimenko, Andrey M; Farfán, Eduardo B; Jannik, G Timothy; Marra, James C
2011-10-01
Fuel-containing materials sampled from within the Chernobyl Nuclear Power Plant (ChNPP) Unit 4 Confinement Shelter were spectroscopically studied for gamma and alpha content. Isotopic ratios for cesium, europium, plutonium, americium, and curium were identified, and the fuel burn-up in these samples was determined. A systematic deviation in the burn-up values based on the cesium isotopes in comparison with other radionuclides was observed. The studies conducted were the first ever performed to demonstrate the presence of significant quantities of 242Cm and 243Cm. It was determined that there was a systematic underestimation of activities of transuranic radionuclides in fuel samples from inside of the ChNPP Confinement Shelter, starting from 241Am (and going higher) in comparison with the theoretical calculations.
Shiwa, Yuh; Hachiya, Tsuyoshi; Furukawa, Ryohei; Ohmomo, Hideki; Ono, Kanako; Kudo, Hisaaki; Hata, Jun; Hozawa, Atsushi; Iwasaki, Motoki; Matsuda, Koichi; Minegishi, Naoko; Satoh, Mamoru; Tanno, Kozo; Yamaji, Taiki; Wakai, Kenji; Hitomi, Jiro; Kiyohara, Yutaka; Kubo, Michiaki; Tanaka, Hideo; Tsugane, Shoichiro; Yamamoto, Masayuki; Sobue, Kenji; Shimizu, Atsushi
2016-01-01
Differences in DNA collection protocols may be a potential confounder in epigenome-wide association studies (EWAS) using a large number of blood specimens from multiple biobanks and/or cohorts. Here we show that pre-analytical procedures involved in DNA collection can induce systematic bias in the DNA methylation profiles of blood cells that can be adjusted by cell-type composition variables. In Experiment 1, whole blood from 16 volunteers was collected to examine the effect of a 24 h storage period at 4°C on DNA methylation profiles as measured using the Infinium HumanMethylation450 BeadChip array. Our statistical analysis showed that the P-value distribution of more than 450,000 CpG sites was similar to the theoretical distribution (in quantile-quantile plot, λ = 1.03) when comparing two control replicates, which was remarkably deviated from the theoretical distribution (λ = 1.50) when comparing control and storage conditions. We then considered cell-type composition as a possible cause of the observed bias in DNA methylation profiles and found that the bias associated with the cold storage condition was largely decreased (λadjusted = 1.14) by taking into account a cell-type composition variable. As such, we compared four respective sample collection protocols used in large-scale Japanese biobanks or cohorts as well as two control replicates. Systematic biases in DNA methylation profiles were observed between control and three of four protocols without adjustment of cell-type composition (λ = 1.12–1.45) and no remarkable biases were seen after adjusting for cell-type composition in all four protocols (λadjusted = 1.00–1.17). These results revealed important implications for comparing DNA methylation profiles between blood specimens from different sources and may lead to discovery of disease-associated DNA methylation markers and the development of DNA methylation profile-based predictive risk models. PMID:26799745
Shiwa, Yuh; Hachiya, Tsuyoshi; Furukawa, Ryohei; Ohmomo, Hideki; Ono, Kanako; Kudo, Hisaaki; Hata, Jun; Hozawa, Atsushi; Iwasaki, Motoki; Matsuda, Koichi; Minegishi, Naoko; Satoh, Mamoru; Tanno, Kozo; Yamaji, Taiki; Wakai, Kenji; Hitomi, Jiro; Kiyohara, Yutaka; Kubo, Michiaki; Tanaka, Hideo; Tsugane, Shoichiro; Yamamoto, Masayuki; Sobue, Kenji; Shimizu, Atsushi
2016-01-01
Differences in DNA collection protocols may be a potential confounder in epigenome-wide association studies (EWAS) using a large number of blood specimens from multiple biobanks and/or cohorts. Here we show that pre-analytical procedures involved in DNA collection can induce systematic bias in the DNA methylation profiles of blood cells that can be adjusted by cell-type composition variables. In Experiment 1, whole blood from 16 volunteers was collected to examine the effect of a 24 h storage period at 4°C on DNA methylation profiles as measured using the Infinium HumanMethylation450 BeadChip array. Our statistical analysis showed that the P-value distribution of more than 450,000 CpG sites was similar to the theoretical distribution (in quantile-quantile plot, λ = 1.03) when comparing two control replicates, which was remarkably deviated from the theoretical distribution (λ = 1.50) when comparing control and storage conditions. We then considered cell-type composition as a possible cause of the observed bias in DNA methylation profiles and found that the bias associated with the cold storage condition was largely decreased (λ adjusted = 1.14) by taking into account a cell-type composition variable. As such, we compared four respective sample collection protocols used in large-scale Japanese biobanks or cohorts as well as two control replicates. Systematic biases in DNA methylation profiles were observed between control and three of four protocols without adjustment of cell-type composition (λ = 1.12-1.45) and no remarkable biases were seen after adjusting for cell-type composition in all four protocols (λ adjusted = 1.00-1.17). These results revealed important implications for comparing DNA methylation profiles between blood specimens from different sources and may lead to discovery of disease-associated DNA methylation markers and the development of DNA methylation profile-based predictive risk models.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soltz, R. A.; Danagoulian, A.; Sheets, S.
Theoretical calculations indicate that the value of the Feynman variance, Y2F for the emitted distribution of neutrons from ssionable exhibits a strong monotonic de- pendence on a the multiplication, M, of a quantity of special nuclear material. In 2012 we performed a series of measurements at the Passport Inc. facility using a 9- MeV bremsstrahlung CW beam of photons incident on small quantities of uranium with liquid scintillator detectors. For the set of objects studies we observed deviations in the expected monotonic dependence, and these deviations were later con rmed by MCNP simulations. In this report, we modify the theorymore » to account for the contri- bution from the initial photo- ssion and benchmark the new theory with a series of MCNP simulations on DU, LEU, and HEU objects spanning a wide range of masses and multiplication values.« less
NASA Technical Reports Server (NTRS)
Bauschlicher, C. W., Jr.; Jaffe, R. L.; Langhoff, S. R.; Partridge, H.; Mascarello, F. G.
1985-01-01
Theoretical calculations of selected excitation energies and oscillator strengths for Ba are presented that overcome the difficulties of previous theoretical treatments. A relativistic effective-core potential treatment is used to account for the relativistic core contraction, but the outermost ten electrons are treated explicitly. Core-valence correlation can be included in this procedure in a rigorous and systematic way through a configuration-interaction calculation. Insight is gained into the importance of relativistic effects by repeating many of the calculations using an all-electron nonrelativistic treatment employing an extended Slater basis set. It is found that the intensity of the intercombination line 3P1-1S0 is accurately determined by accounting for the deviation from LS coupling through spin-orbit mixing with the 1P1 state, and that deviations from the Lande interval rule provide an accurate measure of the degree of mixing.
NASA Astrophysics Data System (ADS)
Zulkifli, A. Z.; Latiff, A. A.; Paul, M. C.; Yasin, M.; Ahmad, H.; Harun, S. W.
2016-12-01
In this paper, a dual-wavelength fiber laser (DWFL) using nano-engineered Thulium-doped fiber as a gain medium with a bent singlemode-multimode-singlemode fiber structure (SMS) is demonstrated. The SMS structure is packaged systematically using Cr-39 polymer plates to provide linear bending via applied load. Experimental results have proved that the bent SMS is capable to provide highly effective wavelength filter and wavelengths stabilizer by balancing the net cavity gain between the two wavelengths. The DWFL provides very narrow spacing of 0.9 nm, narrow 3 dB spectral linewidth of ∼0.07 nm and SNR of ∼42 dB. Based on stability test, very small mode hopping is observed at the two wavelengths having deviations of ±0 nm and ±0.04 nm respectively. In conjunction, the DWFL provides very stable relative wavelength spacing with a deviation of ±0.04 nm.
A holistic approach to SIM platform and its application to early-warning satellite system
NASA Astrophysics Data System (ADS)
Sun, Fuyu; Zhou, Jianping; Xu, Zheyao
2018-01-01
This study proposes a new simulation platform named Simulation Integrated Management (SIM) for the analysis of parallel and distributed systems. The platform eases the process of designing and testing both applications and architectures. The main characteristics of SIM are flexibility, scalability, and expandability. To improve the efficiency of project development, new models of early-warning satellite system were designed based on the SIM platform. Finally, through a series of experiments, the correctness of SIM platform and the aforementioned early-warning satellite models was validated, and the systematical analyses for the orbital determination precision of the ballistic missile during its entire flight process were presented, as well as the deviation of the launch/landing point. Furthermore, the causes of deviation and prevention methods will be fully explained. The simulation platform and the models will lay the foundations for further validations of autonomy technology in space attack-defense architecture research.
Indication of multiscaling in the volatility return intervals of stock markets
NASA Astrophysics Data System (ADS)
Wang, Fengzhong; Yamasaki, Kazuko; Havlin, Shlomo; Stanley, H. Eugene
2008-01-01
The distribution of the return intervals τ between price volatilities above a threshold height q for financial records has been approximated by a scaling behavior. To explore how accurate is the scaling and therefore understand the underlined nonlinear mechanism, we investigate intraday data sets of 500 stocks which consist of Standard & Poor’s 500 index. We show that the cumulative distribution of return intervals has systematic deviations from scaling. We support this finding by studying the m -th moment μm≡⟨(τ/⟨τ⟩)m⟩1/m , which show a certain trend with the mean interval ⟨τ⟩ . We generate surrogate records using the Schreiber method, and find that their cumulative distributions almost collapse to a single curve and moments are almost constant for most ranges of ⟨τ⟩ . Those substantial differences suggest that nonlinear correlations in the original volatility sequence account for the deviations from a single scaling law. We also find that the original and surrogate records exhibit slight tendencies for short and long ⟨τ⟩ , due to the discreteness and finite size effects of the records, respectively. To avoid as possible those effects for testing the multiscaling behavior, we investigate the moments in the range 10<⟨τ⟩≤100 , and find that the exponent α from the power law fitting μm˜⟨τ⟩α has a narrow distribution around α≠0 which depends on m for the 500 stocks. The distribution of α for the surrogate records are very narrow and centered around α=0 . This suggests that the return interval distribution exhibits multiscaling behavior due to the nonlinear correlations in the original volatility.
Briguglio, Antonino; Hohenegger, Johann; Less, György
2015-01-01
Four specimens of larger benthic foraminifera (the Recent Palaeonummulites venosus and Operculina ammonoides, and the phylogenetically related Paleogene Nummulites fabianii and N. fichteli) were investigated by X-ray tomography. The resulting three-dimensional measurements enabled a comprehensive, quantitative study of shell morphology to interpret cell growth without specific shell preparation and/or destruction. After segmentation and extraction of all scanned lumina, the following characters were measured on all chambers of each specimen: chamber volume, septal distance, chamber height, and chamber width. The sequence of chamber lumina follows either a logistic function (Palaeonummulites, Operculina), where the deceleration in growth rate of the latest chambers could mark the onset of reproduction, or it can be modeled by a series of stepwise functions with differing constants (Nummulites). Variations around the growth model are either periodic, following external cycles, or random as expressed by abrupt deviations. Therefore, they may reflect the response of the cell to environmental changes in terms of cyclic changes (e.g., seasonality) or single events (e.g., predator attack). Correlations between chamber volume and the other chamber parameters show that septal distance always matches the sequence in chamber volume and can therefore be used as a proxy for environmental analyses in both growth models. Chamber height and width often remain constant around their function and rarely deviate drastically to accommodate the needed lumen for retaining test size and shape. Chamber width may vary according to chamber volume in involute specimens, whereas both chamber height and width correlate with volume in those tests following an Archimedean spiral. X-ray-tomography shows particular promise in determining which parameters that can be assessed routinely in two dimensions primarily reflect environmental conditions vs. parameters best used for taxonomic identification and for systematic lineage reconstruction. PMID:26166915
NASA Astrophysics Data System (ADS)
Nüske, Feliks; Wu, Hao; Prinz, Jan-Hendrik; Wehmeyer, Christoph; Clementi, Cecilia; Noé, Frank
2017-03-01
Many state-of-the-art methods for the thermodynamic and kinetic characterization of large and complex biomolecular systems by simulation rely on ensemble approaches, where data from large numbers of relatively short trajectories are integrated. In this context, Markov state models (MSMs) are extremely popular because they can be used to compute stationary quantities and long-time kinetics from ensembles of short simulations, provided that these short simulations are in "local equilibrium" within the MSM states. However, over the last 15 years since the inception of MSMs, it has been controversially discussed and not yet been answered how deviations from local equilibrium can be detected, whether these deviations induce a practical bias in MSM estimation, and how to correct for them. In this paper, we address these issues: We systematically analyze the estimation of MSMs from short non-equilibrium simulations, and we provide an expression for the error between unbiased transition probabilities and the expected estimate from many short simulations. We show that the unbiased MSM estimate can be obtained even from relatively short non-equilibrium simulations in the limit of long lag times and good discretization. Further, we exploit observable operator model (OOM) theory to derive an unbiased estimator for the MSM transition matrix that corrects for the effect of starting out of equilibrium, even when short lag times are used. Finally, we show how the OOM framework can be used to estimate the exact eigenvalues or relaxation time scales of the system without estimating an MSM transition matrix, which allows us to practically assess the discretization quality of the MSM. Applications to model systems and molecular dynamics simulation data of alanine dipeptide are included for illustration. The improved MSM estimator is implemented in PyEMMA of version 2.3.
Briguglio, Antonino; Hohenegger, Johann; Less, György
2013-01-01
Four specimens of larger benthic foraminifera (the Recent Palaeonummulites venosus and Operculina ammonoides , and the phylogenetically related Paleogene Nummulites fabianii and N. fichteli ) were investigated by X-ray tomography. The resulting three-dimensional measurements enabled a comprehensive, quantitative study of shell morphology to interpret cell growth without specific shell preparation and/or destruction. After segmentation and extraction of all scanned lumina, the following characters were measured on all chambers of each specimen: chamber volume, septal distance, chamber height, and chamber width. The sequence of chamber lumina follows either a logistic function ( Palaeonummulites , Operculina ), where the deceleration in growth rate of the latest chambers could mark the onset of reproduction, or it can be modeled by a series of stepwise functions with differing constants ( Nummulites ). Variations around the growth model are either periodic, following external cycles, or random as expressed by abrupt deviations. Therefore, they may reflect the response of the cell to environmental changes in terms of cyclic changes (e.g., seasonality) or single events (e.g., predator attack). Correlations between chamber volume and the other chamber parameters show that septal distance always matches the sequence in chamber volume and can therefore be used as a proxy for environmental analyses in both growth models. Chamber height and width often remain constant around their function and rarely deviate drastically to accommodate the needed lumen for retaining test size and shape. Chamber width may vary according to chamber volume in involute specimens, whereas both chamber height and width correlate with volume in those tests following an Archimedean spiral. X-ray-tomography shows particular promise in determining which parameters that can be assessed routinely in two dimensions primarily reflect environmental conditions vs. parameters best used for taxonomic identification and for systematic lineage reconstruction.
Cairnduff, Victoria; Dean, Moira; Koidis, Anastasios
2016-09-01
Food preparation and storage behaviors in the home deviating from the "best practice" food safety recommendations may result in foodborne illnesses. Currently, there are limited tools available to fully evaluate the consumer knowledge, perceptions, and behavior in the area of refrigerator safety. The current study aimed to develop a valid and reliable tool in the form of a questionnaire, the Consumer Refrigerator Safety Questionnaire (CRSQ), for assessing systematically all these aspects. Items relating to refrigerator safety knowledge (n =17), perceptions (n =46), and reported behavior (n =30) were developed and pilot tested by an expert reference group and various consumer groups to assess face and content validity (n =20), item difficulty and consistency (n =55), and construct validity (n =23). The findings showed that the CRSQ has acceptable face and content validity with acceptable levels of item difficulty. Item consistency was observed for 12 of 15 in refrigerator safety knowledge. Further, all 5 of the subscales of consumer perceptions of refrigerator safety practices relating to risk of developing foodborne disease showed acceptable internal consistency (Cronbach's α value > 0.8). Construct validity of the CRSQ was shown to be very good (P = 0.022). The CRSQ exhibited acceptable test-retest reliability at 14 days with the majority of knowledge items (93.3%) and reported behavior items (96.4%) having correlation coefficients of greater than 0.70. Overall, the CRSQ was deemed valid and reliable in assessing refrigerator safety knowledge and behavior; therefore, it has the potential for future use in identifying groups of individuals at increased risk of deviating from recommended refrigerator safety practices, as well as the assessment of refrigerator safety knowledge and behavior for use before and after an intervention.
Evaluation of impression accuracy for a four-implant mandibular model--a digital approach.
Stimmelmayr, Michael; Erdelt, Kurt; Güth, Jan-Frederik; Happe, Arndt; Beuer, Florian
2012-08-01
Implant-supported prosthodontics requires precise impressions to achieve a passive fit. Since the early 1990s, in vitro studies comparing different implant impression techniques were performed, capturing the data mostly mechanically. The purpose of this study was to evaluate the accuracy of three different impression techniques digitally. Dental implants were inserted bilaterally in ten polymer lower-arch models at the positions of the first molars and canines. From each original model, three different impressions (A, transfer; B, pick-up; and C, splinted pick-up) were taken. Scan-bodies were mounted on the implants of the polymer and on the lab analogues of the stone models and digitized. The scan-body in position 36 (FDI) of the digitized original and master casts were each superimposed, and the deviations of the remaining three scan-bodies were measured three-dimensionally. The systematic error of digitizing the models was 13 μm for the polymer and 5 μm for the stone model. The mean discrepancies of the original model to the stone casts were 124 μm (±34) μm for the transfer technique, 116 (±46) μm for the pick-up technique, and 80 (±25) μm for the splinted pick-up technique. There were statistically significant discrepancies between the evaluated impression techniques (p ≤ 0.025; ANOVA test). The splinted pick-up impression showed the least deviation between original and stone model; transfer and pick-up techniques showed similar results. For better accuracy of implant-supported prosthodontics, the splinted pick-up technique should be used for impressions of four implants evenly spread in edentulous jaws.
Mills, Kathryn; Hunt, Michael A; Ferber, Reed
2013-10-01
To identify which gait deviations are consistently associated with knee osteoarthritis (KOA) and how these are influenced by disease severity, the involved compartment, and sex. Five electronic databases and reference lists of publications were searched. Cross-sectional, observational studies comparing temporospatial variables, joint kinematics, and joint moments between individuals with KOA and healthy controls or between KOA subgroups were considered for review. Only publications scoring ≥50% on a modified methodology quality index were included. Because of the number of gait deviations examined, only biomechanical variables reported by ≥4 publications were further analyzed. Where possible, a meta-analysis was performed using effect sizes (ES) calculated from discrete variables. In total, 41 publications examining 20 variables were included. The majority of consistent gait deviations associated with KOA were exhibited by those with severe disease in the temporospatial domain. Individuals with severe KOA exhibited greater stride duration than controls (ES 1.35 [95% confidence interval (95% CI) 1.03, 1.67]) and a decrease in cadence (ES -0.75 [95% CI -1.12, -0.39]) compared with controls. The evidence for kinematic and joint moment change was primarily limited or conflicting. There was a lack of evidence for alterations in the external knee adduction moment. Individuals with KOA exhibit a range of gait deviations compared with controls. Despite its common usage in KOA gait studies, we did not find consistent evidence that knee adduction moment differs between those with and without KOA or between disease severity levels. Further research examining the reasons for a lack of difference in many gait variables in those with knee OA is needed. Copyright © 2013 by the American College of Rheumatology.
CAD/CAM produces dentures with improved fit.
Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca
2018-02-22
Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.
The Ghanaian Economic Recovery
2013-12-01
Adjustment Programs6 instituted by the IMF and World Bank, combined with currency devaluation and smaller government, are responsible for Ghana’s recent...study shows that every negative deviation year was preceded by protectionist policies, and, with one exception (explained by currency devaluation ...negative deviation year was preceded by protectionist policies, and, with one exception (explained by currency devaluation ), every positive deviation
Toward unbiased determination of the redshift evolution of Lyman-alpha forest clouds
NASA Technical Reports Server (NTRS)
Lu, Limin; Zuo, Lin
1994-01-01
The possibility of using D(sub A), the mean depression of a quasar spectrum due to Ly-alpha forest absorption, to study the number density evolution of the Ly-alpha forest clouds is examined in some detail. Current D(sub A) measurements are made against a continuum that is a power-law extrapolation from the continuum longward of Ly-alpha emission. Compared to the line-counting approach, the D(sub A)-method has the advantage that the D(sub A) measurements are not affected by line-blending effects. However, we find using low-redshift quasar spectra obtained with the Hubble Space Telescope (HST), where the true continuum in the Ly-alpha forest can be estimated fairly reliably because of the much lower density of the Ly-alpha forest lines, that the extrapolated continuum often deviates systematically from the true continuum in the forest region. Such systematic continuum errors introduce large errors in the D(sub A) measurements. The current D(sub A) measurements may also be significantly biased by the possible presence of the Gunn-Peterson absorption. We propose a modification to the existing D(sub A)-method, namely, to measure D(sub A) against a locally established continuum in the Ly-alpha forest. Under conditions that the quasar spectrum has good resolution and S/N to allow for a reliable estimate of the local continuum in the Ly-alpha forest, the modified D(sub A) measurements should be largely free of the systematic uncertainties suffered by the existing D(sub A) measurements. We also introduce a formalism based on the work of Zuo (1993) to simplify the application of the D(sub A)-method(s) to real data. We discuss the merits and limitations of the modified D(sub A)-method, and conclude that it is a useful alternative. Our findings that the extrapolated continuum from longward of Ly-alpha emission often deviates systematically from the true continuum in the Ly-alpha forest present a major problem in the study of the Gunn-Peterson absorption.
Robitschek, Jon; Dresner, Harley; Hilger, Peter
2017-12-01
Photographic nasal analysis constitutes a critical step along the path toward accurate diagnosis and precise surgical planning in rhinoplasty. The learned process by which one assesses photographs, analyzes relevant anatomical landmarks, and generates a global view of the nasal aesthetic is less widely described. To discern the common pitfalls in performing photographic nasal analysis and to quantify the utility of a systematic approach model in teaching photographic nasal analysis to otolaryngology residents. This prospective observational study included 20 participants from a university-based otolaryngology residency program. The control and intervention groups underwent baseline graded assessment of 3 patients. The intervention group received instruction on a systematic approach model for nasal analysis, and both groups underwent postintervention testing at 10 weeks. Data were collected from October 1, 2015, through June 1, 2016. A 10-minute, 11-slide presentation provided instruction on a systematic approach to nasal analysis to the intervention group. Graded photographic nasal analysis using a binary 18-point system. The 20 otolaryngology residents (15 men and 5 women; age range, 24-34 years) were adept at mentioning dorsal deviation and dorsal profile with focused descriptions of tip angle and contour. Areas commonly omitted by residents included verification of the Frankfort plane, position of the lower lateral crura, radix position, and ratio of the ala to tip lobule. The intervention group demonstrated immediate improvement after instruction on the teaching model, with the mean (SD) postintervention test score doubling compared with their baseline performance (7.5 [2.7] vs 10.3 [2.5]; P < .001). At 10 weeks after the intervention, the mean comparative improvement in overall graded nasal analysis was 17% (95% CI, 10%-23%; P < .001). Otolaryngology residents demonstrated proficiency at incorporating nasal deviation, tip angle, and dorsal profile contour into their nasal analysis. They often omitted verification of the Frankfort plane, position of lower lateral crura, radix depth, and ala-to-tip lobule ratio. Findings with this novel 10-minute teaching model should be validated at other teaching institutions, and the instruction model should be further enhanced to teach more sophisticated analysis to residents as they proceed through training. NA.
A compensated multi-pole linear ion trap mercury frequency standard for ultra-stable timekeeping.
Burt, Eric A; Diener, William A; Tjoelker, Robert L
2008-12-01
The multi-pole linear ion trap frequency standard (LITS) being developed at the Jet Propulsion Laboratory (JPL) has demonstrated excellent short- and long-term stability. The technology has now demonstrated long-term field operation providing a new capability for timekeeping standards. Recently implemented enhancements have resulted in a record line Q of 5 x 10(12) for a room temperature microwave atomic transition and a short-term fractional frequency stability of 5 x 10(-14)/tau(1/2). A scheme for compensating the second order Doppler shift has led to a reduction of the combined sensitivity to the primary LITS systematic effects below 5 x 10(-17) fractional frequency. Initial comparisons to JPL's cesium fountain clock show a systematic floor of less than 2 x 10(-16). The compensated multi-pole LITS at JPL was operated continuously and unattended for a 9-mo period from October 2006 to July 2007. During that time it was used as the frequency reference for the JPL geodetic receiver known as JPLT, enabling comparisons to any clock used as a reference for an International GNSS Service (IGS) site. Comparisons with the laser-cooled primary frequency standards that reported to the Bureau International des Poids et Mesures (BIPM) over this period show a frequency deviation less than 2.7 x 10(-17)/day. In the capacity of a stand-alone ultra-stable flywheel, such a standard could be invaluable for long-term timekeeping applications in metrology labs while its methodology and robustness make it ideal for space applications as well.
A simplified physical model for assessing solar radiation over Brazil using GOES 8 visible imagery
NASA Astrophysics Data System (ADS)
Ceballos, Juan Carlos; Bottino, Marcus Jorge; de Souza, Jaidete Monteiro
2004-01-01
Solar radiation assessment by satellite is constrained by physical limitations of imagery and by the accuracy of instantaneous local atmospheric parameters, suggesting that one should use simplified but physically consistent models for operational work. Such a model is presented for use with GOES 8 imagery applied to atmospheres with low aerosol optical depth. Fundamental satellite-derived parameters are reflectance and cloud cover. A classification method applied to a set of images shows that reflectance, usually defined as upper-threshold Rmax in algorithms assessing cloud cover, would amount ˜0.465, corresponding to the transition between a cumuliform and a stratiform cloud field. Ozone absorption is limited to the stratosphere. The model considers two spectral broadband intervals for tropospheric radiative transfer: ultraviolet and visible intervals are essentially nonabsorbing and can be processed as a single interval, while near-infrared intervals have negligible atmospheric scattering and very low cloud transmittance. Typical values of CO2 and O3 content and of precipitable water are considered. A comparison of daily values of modeled mean irradiance with data of three sites (in rural, urban industrial, and urban coastal environments), September-October 2002, exhibits a bias of +5 W m-2 and a standard deviation of ˜15 W m-2 (0.4 and 1.3 MJ m-2 for daily irradiation). A comparison with monthly means from about 80 automatic weather stations (covering a large area throughout the Brazilian territory) still shows a bias generally within ±10 W m-2 and a low standard deviation (<20 W m-2), but the bias has a trend in September-December 2002, suggesting an annual cycle of local Rmax values. Systematic (mean) errors in partial cloud cover and in nearly clear-sky situations may be enhanced using regional values for atmospheric and surface parameters, such as precipitable water, Rmax, and ground reflectance. The larger errors are observed in situations of high aerosol load (especially in regions with industrial activity or forest or agricultural fires). The last case is evident when sites in the Amazonian region or São Paulo city are selected. When considering daily values averaged within 2.5° × 2.5° cells, the standard error is lower than 20 W m-2; present results suggest an annual cycle of mean bias ranging from +10 to -10 W m-2, with an amplitude of ˜10 W m-2. These values are close to the proposed requirements of 10 W m-2 for the mean deviation and 25 W m-2 for the standard deviation. It is expected that the introduction of a reference grid containing mean values of parameters within a cell could induce a decrease in the standard deviation of mean errors and the correction of their annual cycle. A model adaptation for assessing the effect of high aerosol loads is needed in order to extend improvements to the whole Brazilian area.
NASA Astrophysics Data System (ADS)
Møller, Søren H.; Vester-Petersen, Joakim; Nazir, Adnan; Eriksen, Emil H.; Julsgaard, Brian; Madsen, Søren P.; Balling, Peter
2018-02-01
Quantitative measurements of the electric near-field distribution of star-shaped gold nanoparticles have been performed by femtosecond laser ablation. Measurements were carried out on and off the plasmon resonance. A detailed comparison with numerical simulations of the electric fields is presented. Semi-quantitative agreement is found, with slight systematic differences between experimentally observed and simulated near-field patterns close to strong electric-field gradients. The deviations are attributed to carrier transport preceding ablation.
Viking relativity experiment - Verification of signal retardation by solar gravity
NASA Technical Reports Server (NTRS)
Reasenberg, R. D.; Shapiro, I. I.; Macneil, P. E.; Goldstein, R. B.; Breidenthal, J. C.; Brenkle, J. P.; Cain, D. L.; Kaufman, T. M.; Komarek, T. A.; Zygielbaum, A. I.
1979-01-01
Analysis of 14 months of data obtained from radio ranging to the Viking spacecraft verified, to an estimated accuracy of 0.1%, the prediction of the general theory of relativity that the round-trip times of light signals traveling between the earth and Mars are increased by the direct effect of solar gravity. The corresponding value for the metric parameter gamma is 1.000 plus or minus 0.002, where the quoted uncertainty, twice the formal standard deviation, allows for possible systematic errors.
Potential bias in TEOS10 density of sea water samples
NASA Astrophysics Data System (ADS)
Budéus, G. Th.
2018-04-01
Direct density measurements of ocean water samples are compared to TEOS10 derived densities. The water sample set includes waters from remote areas as Antarctic waters and the central Arctic, but also waters of regions that resemble closely the reference composition of TEOS10. With few exceptions, the measured densities are smaller than those derived according to TEOS10. The result suggests a potential systematic overestimation of density by TEOS10. For the majority of waters the deviations are about 10 g/m3.
Key comparison CCPR-K1.a as an interlaboratory comparison of correlated color temperature
NASA Astrophysics Data System (ADS)
Kärhä, P.; Vaskuri, A.; Pulli, T.; Ikonen, E.
2018-02-01
We analyze the results of spectral irradiance key comparison CCPR-K1.a for correlated color temperature (CCT). For four participants out of 13, the uncertainties of CCT, calculated using traditional methods, not accounting for correlations, would be too small. The reason for the failure of traditional uncertainty calculation is spectral correlations, producing systematic deviations of the same sign over certain wavelength regions. The results highlight the importance of accounting for such correlations when calculating uncertainties of spectrally integrated quantities.
NASA Astrophysics Data System (ADS)
Cahyono, A. B.; Deviantari, U. W.
2017-12-01
According to statutory regulation issued by Ministry of Land and Spatial Planning/Head of National Land Agency (BPN) number 35/2016, Comprehensive Systematic land registration is a sequential activity of which continuously and systematically carried out by the government ranging from collecting, processing, recording and presenting, as well as maintaining the physical and juridical data in the form of map and list of land-plots and flats, including the transfer of legal title for land plots and flats with their inherent rights. Delineation is one method to identify land plots by utilizing map image or high resolution photo and defining the boundaries by drawing lines to determine the valid and recognizable boundaries. A guideline to delineate the unregistered land plots may be determined from this two methods’ accuracy result, using general boundary applied to aerial photo taken by multicopter RTF. Data taken from a height of 70 meter on an area obtained a number of 156 photos with 5 GCP resulting in an photo map with GSD 2.14 cm. The 11 samples parcels are selected in the sites of ± 7 ha. There are 11 samples of land parcels are tested. The area difference test for every parcel using a average standard deviation of 17,043 indicates that there are three land parcels which have significant area difference and 8 others do not have significant area difference. Based on the tolerance of National Land Agency, among 11 parcels studied, there are 8 parcels that fullfill the tolerances and three others do not fullfill tolerances. The percentage of area difference average between land registration map and orthophoto is 4,72%. The result shows that the differences in boundaries and areas that may be caused by a systematic error of method in describing the boundaries of the ground.
Complexity analysis based on generalized deviation for financial markets
NASA Astrophysics Data System (ADS)
Li, Chao; Shang, Pengjian
2018-03-01
In this paper, a new modified method is proposed as a measure to investigate the correlation between past price and future volatility for financial time series, known as the complexity analysis based on generalized deviation. In comparison with the former retarded volatility model, the new approach is both simple and computationally efficient. The method based on the generalized deviation function presents us an exhaustive way showing the quantization of the financial market rules. Robustness of this method is verified by numerical experiments with both artificial and financial time series. Results show that the generalized deviation complexity analysis method not only identifies the volatility of financial time series, but provides a comprehensive way distinguishing the different characteristics between stock indices and individual stocks. Exponential functions can be used to successfully fit the volatility curves and quantify the changes of complexity for stock market data. Then we study the influence for negative domain of deviation coefficient and differences during the volatile periods and calm periods. after the data analysis of the experimental model, we found that the generalized deviation model has definite advantages in exploring the relationship between the historical returns and future volatility.
Radhika, R; Shankar, R; Vijayakumar, S; Kolandaivel, P
2018-05-01
The theoretical studies on DNA with the anticancer drug 6-Mercaptopurine (6-MP) are investigated using theoretical methods to shed light on drug designing. Among the DNA base pairs considered, 6-MP is stacked with GC with the highest interaction energy of -46.19 kcal/mol. Structural parameters revealed that structure of the DNA base pairs is deviated from the planarity of the equilibrium position due to the formation of hydrogen bonds and stacking interactions with 6-MP. These deviations are verified through the systematic comparison between X-H bond contraction and elongation and the associated blue shift and red shift values by both NBO analysis and vibrational analysis. Bent's rule is verified for the C-H bond contraction in the 6-MP interacted base pairs. The AIM results disclose that the higher values of electron density (ρ) and Laplacian of electron density (∇ 2 ρ) indicate the increased overlap between the orbitals that represent the strong interaction and positive values of the total electron density show the closed-shell interaction. The relative sensitivity of the chemical shift values for the DNA base pairs with 6-MP is investigated to confirm the hydrogen bond strength. Molecular dynamics simulation studies of G-quadruplex DNA d(TGGGGT) 4 with 6-MP revealed that the incorporation of 6-MP appears to cause local distortions and destabilize the G-quadruplex DNA.
Neutronics Investigations for the Lower Part of a Westinghouse SVEA-96+ Assembly
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murphy, M.F.; Luethi, A.; Seiler, R.
2002-05-15
Accurate critical experiments have been performed for the validation of total fission (F{sub tot}) and {sup 238}U-capture (C{sub 8}) reaction rate distributions obtained with CASMO-4, HELIOS, BOXER, and MCNP4B for the lower axial region of a real Westinghouse SVEA-96+ fuel assembly. The assembly comprised fresh fuel with an average {sup 235}U enrichment of 4.02 wt%, a maximum enrichment of 4.74 wt%, 14 burnable-absorber fuel pins, and full-density water moderation. The experimental configuration investigated was core 1A of the LWR-PROTEUS Phase I project, where 61 different fuel pins, representing {approx}64% of the assembly, were gamma-scanned individually. Calculated (C) and measured (E)more » values have been compared in terms of C/E distributions. For F{sub tot}, the standard deviations are 1.2% for HELIOS, 0.9% for CASMO-4, 0.8% for MCNP4B, and 1.7% for BOXER. Standard deviations of 1.1% for HELIOS, CASMO-4, and MCNP4B and 1.2% for BOXER were obtained in the case of C{sub 8}. Despite the high degree of accuracy observed on the average, it was found that the five burnable-absorber fuel pins investigated showed a noticeable underprediction of F{sub tot}, quite systematically, for the deterministic codes evaluated (average C/E for the burnable-absorber fuel pins in the range 0.974 to 0.988, depending on the code)« less
Mean and Fluctuating Force Distribution in a Random Array of Spheres
NASA Astrophysics Data System (ADS)
Akiki, Georges; Jackson, Thomas; Balachandar, Sivaramakrishnan
2015-11-01
This study presents a numerical study of the force distribution within a cluster of mono-disperse spherical particles. A direct forcing immersed boundary method is used to calculate the forces on individual particles for a volume fraction range of [0.1, 0.4] and a Reynolds number range of [10, 625]. The overall drag is compared to several drag laws found in the literature. As for the fluctuation of the hydrodynamic streamwise force among individual particles, it is shown to have a normal distribution with a standard deviation that varies with the volume fraction only. The standard deviation remains approximately 25% of the mean streamwise force on a single sphere. The force distribution shows a good correlation between the location of two to three nearest upstream and downstream neighbors and the magnitude of the forces. A detailed analysis of the pressure and shear forces contributions calculated on a ghost sphere in the vicinity of a single particle in a uniform flow reveals a mapping of those contributions. The combination of the mapping and number of nearest neighbors leads to a first order correction of the force distribution within a cluster which can be used in Lagrangian-Eulerian techniques. We also explore the possibility of a binary force model that systematically accounts for the effect of the nearest neighbors. This work was supported by the National Science Foundation (NSF OISE-0968313) under Partnership for International Research and Education (PIRE) in Multiphase Flows at the University of Florida.
SYFSA: A Framework for Systematic Yet Flexible Systems Analysis
Johnson, Todd R.; Markowitz, Eliz; Bernstam, Elmer V.; Herskovic, Jorge R.; Thimbleby, Harold
2013-01-01
Although technological or organizational systems that enforce systematic procedures and best practices can lead to improvements in quality, these systems must also be designed to allow users to adapt to the inherent uncertainty, complexity, and variations in healthcare. We present a framework, called Systematic Yet Flexible Systems Analysis (SYFSA) that supports the design and analysis of Systematic Yet Flexible (SYF) systems (whether organizational or technical) by formally considering the tradeoffs between systematicity and flexibility. SYFSA is based on analyzing a task using three related problem spaces: the idealized space, the natural space, and the system space. The idealized space represents the best practice—how the task is to be accomplished under ideal conditions. The natural space captures the task actions and constraints on how the task is currently done. The system space specifies how the task is done in a redesigned system, including how it may deviate from the idealized space, and how the system supports or enforces task constraints. The goal of the framework is to support the design of systems that allow graceful degradation from the idealized space to the natural space. We demonstrate the application of SYFSA for the analysis of a simplified central line insertion task. We also describe several information-theoretic measures of flexibility that can be used to compare alternative designs, and to measure how efficiently a system supports a given task, the relative cognitive workload, and learnability. PMID:23727053
NASA Astrophysics Data System (ADS)
Adams, T.; Batra, P.; Bugel, L.; Camilleri, L.; Conrad, J. M.; de Gouvêa, A.; Fisher, P. H.; Formaggio, J. A.; Jenkins, J.; Karagiorgi, G.; Kobilarcik, T. R.; Kopp, S.; Kyle, G.; Loinaz, W. A.; Mason, D. A.; Milner, R.; Moore, R.; Morfín, J. G.; Nakamura, M.; Naples, D.; Nienaber, P.; Olness, F. I.; Owens, J. F.; Pate, S. F.; Pronin, A.; Seligman, W. G.; Shaevitz, M. H.; Schellman, H.; Schienbein, I.; Syphers, M. J.; Tait, T. M. P.; Takeuchi, T.; Tan, C. Y.; van de Water, R. G.; Yamamoto, R. K.; Yu, J. Y.
We extend the physics case for a new high-energy, ultra-high statistics neutrino scattering experiment, NuSOnG (Neutrino Scattering On Glass) to address a variety of issues including precision QCD measurements, extraction of structure functions, and the derived Parton Distribution Functions (PDF's). This experiment uses a Tevatron-based neutrino beam to obtain a sample of Deep Inelastic Scattering (DIS) events which is over two orders of magnitude larger than past samples. We outline an innovative method for fitting the structure functions using a parametrized energy shift which yields reduced systematic uncertainties. High statistics measurements, in combination with improved systematics, will enable NuSOnG to perform discerning tests of fundamental Standard Model parameters as we search for deviations which may hint of "Beyond the Standard Model" physics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farfan, E.; Jannik, T.; Marra, J.
2011-10-01
Fuel-containing materials sampled from within the Chernobyl Nuclear Power Plant (ChNPP) 4th Reactor Unit Confinement Shelter were spectroscopically studied for gamma and alpha content. Isotopic ratios for cesium, europium, plutonium, americium, and curium were identified and the fuel burnup in these samples was determined. A systematic deviation in the burnup values based on the cesium isotopes, in comparison with other radionuclides, was observed. The conducted studies were the first ever performed to demonstrate the presence of significant quantities of {sup 242}Cm and {sup 243}Cm. It was determined that there was a systematic underestimation of activities of transuranic radionuclides in fuelmore » samples from inside of the ChNPP Confinement Shelter, starting from {sup 241}Am (and going higher), in comparison with the theoretical calculations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pizzuti, L.; Sartoris, B.; Borgani, S.
We use high-precision kinematic and lensing measurements of the total mass profile of the dynamically relaxed galaxy cluster MACS J1206.2-0847 at z=0.44 to estimate the value of the ratio η=Ψ/Φ between the two scalar potentials in the linear perturbed Friedmann-Lemaitre-Robertson-Walker metric. An accurate measurement of this ratio, called anisotropic stress, could show possible, interesting deviations from the predictions of the theory of General Relativity, according to which Ψ should be equal to Φ. Complementary kinematic and lensing mass profiles were derived from exhaustive analyses using the data from the Cluster Lensing And Supernova survey with Hubble (CLASH) and the spectroscopicmore » follow-up with the Very Large Telescope (CLASH-VLT). Whereas the kinematic mass profile tracks only the time-time part of the perturbed metric (i.e. only Φ), the lensing mass profile reflects the contribution of both time-time and space-space components (i.e. the sum Φ+Ψ). We thus express η as a function of the mass profiles and perform our analysis over the radial range 0.5 Mpc≤ r≤ r{sub 200}=1.96 Mpc. Using a spherical Navarro-Frenk-White mass profile, which well fits the data, we obtain η(r{sub 200})=1.01 {sub −0.28}{sup +0.31} at the 68% C.L. We discuss the effect of assuming different functional forms for mass profiles and of the orbit anisotropy in the kinematic reconstruction. Interpreting this result within the well-studied f(R) modified gravity model, the constraint on η translates into an upper bound to the interaction length (inverse of the scalaron mass) smaller than 2 Mpc. This tight constraint on the f(R) interaction range is however substantially relaxed when systematic uncertainties in the analysis are considered. Our analysis highlights the potential of this method to detect deviations from general relativity, while calling for the need of further high-quality data on the total mass distribution of clusters and improved control on systematic effects.« less
TH-AB-BRA-04: Dosimetric Evaluation of MR-Guided HDR Brachytherapy Planning for Cervical Cancer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamio, Y; Barkati, M; Beliveau-Nadeau, D
2016-06-15
Purpose: To perform a retrospective study on 16 patients that had both CT and T2-weighted MR scans done at first fraction using the Utrecht CT/MR applicator (Elekta Brachytherapy) in order to evaluate uncertainties associated with an MR-only planning workflow. Methods: MR-workflow uncertainties were classified in three categories: reconstruction, registration and contouring. A systematic comparison of the CT and MR contouring, manual reconstruction and optimization process was performed to evaluate the impact of these uncertainties on the recommended GEC ESTRO DVH parameters: D90% and V100% for HR-CTV as well as D2cc for bladder, rectum, sigmoid colon and small bowel. This comparisonmore » was done using the following four steps: 1. Catheter reconstruction done on MR images with original CT-plan contours and dwell times. 2. OAR contours adjusted on MR images with original CT-plan reconstruction and dwell times. 3. Both reconstruction and contours done on MR images with original CT-plan dwell times. 4. Entire MR-based workflow optimized dwell times reimported to the original CT-plan. Results: The MR-based reconstruction process showed average D2cc deviations of 4.5 ± 3.0%, 1.5 ± 2.0%, 2.5 ± 2.0% and 2.0 ± 1.0% for the bladder, rectum, sigmoid colon and small bowels respectively with a maximum of 10%, 6%, 6% and 4%. The HR-CTV’s D90% and V100% average deviations was found to be 4.0 ± 3.0%, and 2.0 ± 2.0% respectively with a maximum of 10% and 6%. Adjusting contours on MR-images was found to have a similar impact. Finally, the optimized MR-based workflow dwell times were found to still give acceptable plans when re-imported to the original CT-plan which validated the entire workflow. Conclusion: This work illustrates a systematic validation method for centers wanting to move towards an MR-only workflow. This work will be expanded to model based reconstruction, PD-weighted images and other types of applicators.« less
Weir, Christopher J; Butcher, Isabella; Assi, Valentina; Lewis, Stephanie C; Murray, Gordon D; Langhorne, Peter; Brady, Marian C
2018-03-07
Rigorous, informative meta-analyses rely on availability of appropriate summary statistics or individual participant data. For continuous outcomes, especially those with naturally skewed distributions, summary information on the mean or variability often goes unreported. While full reporting of original trial data is the ideal, we sought to identify methods for handling unreported mean or variability summary statistics in meta-analysis. We undertook two systematic literature reviews to identify methodological approaches used to deal with missing mean or variability summary statistics. Five electronic databases were searched, in addition to the Cochrane Colloquium abstract books and the Cochrane Statistics Methods Group mailing list archive. We also conducted cited reference searching and emailed topic experts to identify recent methodological developments. Details recorded included the description of the method, the information required to implement the method, any underlying assumptions and whether the method could be readily applied in standard statistical software. We provided a summary description of the methods identified, illustrating selected methods in example meta-analysis scenarios. For missing standard deviations (SDs), following screening of 503 articles, fifteen methods were identified in addition to those reported in a previous review. These included Bayesian hierarchical modelling at the meta-analysis level; summary statistic level imputation based on observed SD values from other trials in the meta-analysis; a practical approximation based on the range; and algebraic estimation of the SD based on other summary statistics. Following screening of 1124 articles for methods estimating the mean, one approximate Bayesian computation approach and three papers based on alternative summary statistics were identified. Illustrative meta-analyses showed that when replacing a missing SD the approximation using the range minimised loss of precision and generally performed better than omitting trials. When estimating missing means, a formula using the median, lower quartile and upper quartile performed best in preserving the precision of the meta-analysis findings, although in some scenarios, omitting trials gave superior results. Methods based on summary statistics (minimum, maximum, lower quartile, upper quartile, median) reported in the literature facilitate more comprehensive inclusion of randomised controlled trials with missing mean or variability summary statistics within meta-analyses.
Observations of the global haze redistribution on Titan from 2006 to 2015 with OSIRIS at Keck
NASA Astrophysics Data System (ADS)
Ádámkovics, Máté; de Pater, Imke
2017-07-01
We observed Titan with the OH Suppressing InfraRed Imaging Spectrograph (OSIRIS) at the W. M. Keck observatory from 2006 through 2015 using adaptive optics. The sunlight scattered by atmospheric haze was spatially resolved in the 2.0 μm (K) band window, and the spectra were analyzed with a radiative transfer model to determine the vertical (altitude) and meridional (latitudinal) variation in the haze distribution over this time period. This study complements recent work by Karkoschka (2016) in the season of observations, in the time span and sampling interval, in wavelength coverage and spectral resolution, as well as in the radiative transfer methodology and analysis. We observe the largest meridional gradient in haze opacity above 20 km toward the northern hemisphere in January 2010. Individual observations can show significant deviations from a relatively smooth linear gradient in haze across the entire disk. The variation in haze below 20 km is rarely well-described by a simple model and there is a systematically smaller amount of haze opacity retrieved from the equator to 10° S when observing the disk with a sub-observer longitude near 150° W. This correlation with longitude suggests one of the following; a localized decrease in haze scattering, a localized increase in gas opacity, or a systematic over-estimate of the surface albedo in this region.
NASA Astrophysics Data System (ADS)
Lewerenz, Meinert; Münnix, Jens; Schmalstieg, Johannes; Käbitz, Stefan; Knips, Marcus; Sauer, Dirk Uwe
2017-03-01
The contribution introduces a new theory explaining the capacity increase that is often observed in early stages of life of lithium-ion batteries. This reversible and SOC-depending capacity rise is explained by the passive electrode effect in this work. The theory assumes a slow, compensating flow of active lithium between the passive and the active part of the anode, where the passive part represents the geometric excess anode with respect to the cathode. The theory is validated using a systematic test of 50 cylindrical 8 Ah LiFePO4|Graphite battery cells analyzed during cyclic and calendaric aging. The cyclic aging has been performed symmetrically at 40 °C cell temperature, varying current rates and DODs. The calendar aging is executed at three temperatures and up to four SOCs. The aging is dominated by capacity fade while the increase of internal resistance is hardly influenced. Surprisingly shallow cycling between 45 and 55% SOC shows stronger aging than aging at higher DOD and tests at 4 C exhibit less aging than aging at lower C-rates. Aging mechanisms at 60 °C seem to deviate from those at 40 °C or lower. The data of this aging matrix is used for further destructive and non-destructive characterization in future contributions.
Systematic description of the effect of particle shape on the strength properties of granular media
NASA Astrophysics Data System (ADS)
Azéma, Emilien; Estrada, Nicolas; Preechawuttipong, Itthichai; Delenne, Jean-Yves; Radjai, Farhang
2017-06-01
In this paper, we explore numerically the effect of particle shape on the mechanical behavior of sheared granular packings. In the framework of the Contact Dynamic (CD)Method, we model angular shape as irregular polyhedral particles, non-convex shape as regular aggregates of four overlapping spheres, elongated shape as rounded cap rectangles and platy shape as square-plates. Binary granular mixture consisting of disks and elongated particles are also considered. For each above situations, the number of face of polyhedral particles, the overlap of spheres, the aspect ratio of elongated and platy particles, are systematically varied from spheres to very angular, non-convex, elongated and platy shapes. The level of homogeneity of binary mixture varies from homogenous packing to fully segregated packings. Our numerical results suggest that the effects of shape parameters are nonlinear and counterintuitive. We show that the shear strength increases as shape deviate from spherical shape. But, for angular shapes it first increases up to a maximum value and then saturates to a constant value as the particles become more angular. For mixture of two shapes, the strength increases with respect of the increase of the proportion of elongated particles, but surprisingly it is independent with the level of homogeneity of the mixture. A detailed analysis of the contact network topology, evidence that various contact types contribute differently to stress transmission at the micro-scale.
Aerosol Optical Depth as Observed by the Mars Science Laboratory REMS UV Photodiodes
NASA Technical Reports Server (NTRS)
Smith, M. D.; Zorzano, M.-P.; Lemmon, M.; Martin-Torres, J.; Mendaza de Cal, T.
2017-01-01
Systematic observations taken by the REMS UV photodiodes on a daily basis throughout the landed Mars Science Laboratory mission provide a highly useful tool for characterizing aerosols above Gale Crater. Radiative transfer modeling is used to model the approximately two Mars Years of observations taken to date taking into account multiple scattering from aerosols and the extended field of view of the REMS UV photodiodes. The retrievals show in detail the annual cycle of aerosol optical depth, which is punctuated with numerous short timescale events of increased optical depth. Dust deposition onto the photodiodes is accounted for by comparison with aerosol optical depth derived from direct imaging of the Sun by Mastcam. The effect of dust on the photodiodes is noticeable, but does not dominate the signal. Cleaning of dust from the photodiodes was observed in the season around Ls=270deg, but not during other seasons. Systematic deviations in the residuals from the retrieval fit are indicative of changes in aerosol effective particle size, with larger particles present during periods of increased optical depth. This seasonal dependence of aerosol particle size is expected as dust activity injects larger particles into the air, while larger aerosols settle out of the atmosphere more quickly leading to a smaller average particle size over time. A full description of these observations, the retrieval algorithm, and the results can be found in Smith et al. (2016).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wen, N., E-mail: nwen1@hfhs.org; Snyder, K. C.; Qin, Y.
2016-05-15
Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2more » mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balderson, Michael, E-mail: michael.balderson@rmp.uhn.ca; Brown, Derek; Johnson, Patricia
The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic–based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for themore » different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15 mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT.« less
40 CFR 63.8640 - What records must I keep?
Code of Federal Regulations, 2010 CFR
2010-07-01
... to show continuous compliance with each emission limitation that applies to you. (c) You must also... deviation of an operating limit parameter value, the date, time, and duration of the deviation, a brief...
Volckmann, Pierre; Jacquin-Courtois, Sophie
2016-01-01
Complex Regional Pain Syndrome (CRPS) is an invalidating chronic condition subsequent to peripheral lesions. There is growing consensus for a central contribution to CRPS. However, the nature of this central body representation disorder is increasingly debated. Although it has been repeatedly argued that CRPS results in motor neglect of the affected side, visual egocentric reference frame was found to be deviated toward the pain, that is, neglect of the healthy side. Accordingly, prism adaptation has been successfully used to normalize this deviation. This study aimed at clarifying whether 7 CRPS patients exhibited neglect as well as exploring the pathophysiological mechanisms of this manifestation and of the therapeutic effects of prism adaptation. Pain and quality of life, egocentric reference frames (visual and proprioceptive straight-ahead), and neglect tests (line bisection, kinematic analyses of motor neglect and motor extinction) were repeatedly assessed prior to, during, and following a one-week intense prism adaptation intervention. First, our results provide no support for visual and motor neglect in CRPS. Second, reference frames for body representations were not systematically deviated. Third, intensive prism adaptation intervention durably ameliorated pain and quality of life. As for spatial neglect, understanding the therapeutic effects of prism adaptation deserves further investigations. PMID:27668094
Downs, Stephen; Marquez, Jodie; Chiarelli, Pauline
2014-06-01
What is the mean Berg Balance Scale score of healthy elderly people living in the community and how does it vary with age? How much variability in Berg Balance Scale scores is present in groups of healthy elderly people and how does this vary with age? Systematic review with meta-analysis. Any group of healthy community-dwelling people with a mean age of 70 years or greater that has undergone assessment using the Berg Balance Scale. Mean and standard deviations of Berg Balance Scale scores within cohorts of elderly people of known mean age. The search yielded 17 relevant studies contributing data from a total of 1363 participants. The mean Berg Balance Scale scores ranged from 37 to 55 out of a possible maximum score of 56. The standard deviation of Berg Balance Scale scores varied from 1.0 to 9.2. Although participants aged around 70 years had very close to normal Berg Balance Scale scores, there was a significant decline in balance with age at a rate of 0.7 points on the 56-point Berg Balance Scale per year. There was also a strong association between increasing age and increasing variability in balance (R(2) = 0.56, p < 0.001). Healthy community-dwelling elderly people have modest balance deficits, as measured by the Berg Balance Scale, although balance scores deteriorate and become more variable with age. Copyright © 2014. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Elsner, F.; Feulner, G.; Hopp, U.
2008-01-01
Aims:We estimate stellar masses of galaxies in the high redshift universe with the intention of determining the influence of newly available Spitzer/IRAC infrared data on the analysis. Based on the results, we probe the mass assembly history of the universe. Methods: We use the GOODS-MUSIC catalog, which provides multiband photometry from the U-filter to the 8 μm Spitzer band for almost 15 000 galaxies with either spectroscopic (for ≈7% of the sample) or photometric redshifts, and apply a standard model fitting technique to estimate stellar masses. We than repeat our calculations with fixed photometric redshifts excluding Spitzer photometry and directly compare the outcomes to look for systematic deviations. Finally we use our results to compute stellar mass functions and mass densities up to redshift z = 5. Results: We find that stellar masses tend to be overestimated on average if further constraining Spitzer data are not included into the analysis. Whilst this trend is small up to intermediate redshifts z ⪉ 2.5 and falls within the typical error in mass, the deviation increases strongly for higher redshifts and reaches a maximum of a factor of three at redshift z ≈ 3.5. Thus, up to intermediate redshifts, results for stellar mass density are in good agreement with values taken from literature calculated without additional Spitzer photometry. At higher redshifts, however, we find a systematic trend towards lower mass densities if Spitzer/IRAC data are included.
Artes, Paul H; Henson, David B; Harper, Robert; McLeod, David
2003-06-01
To compare a multisampling suprathreshold strategy with conventional suprathreshold and full-threshold strategies in detecting localized visual field defects and in quantifying the area of loss. Probability theory was applied to examine various suprathreshold pass criteria (i.e., the number of stimuli that have to be seen for a test location to be classified as normal). A suprathreshold strategy that requires three seen or three missed stimuli per test location (multisampling suprathreshold) was selected for further investigation. Simulation was used to determine how the multisampling suprathreshold, conventional suprathreshold, and full-threshold strategies detect localized field loss. To determine the systematic error and variability in estimates of loss area, artificial fields were generated with clustered defects (0-25 field locations with 8- and 16-dB loss) and, for each condition, the number of test locations classified as defective (suprathreshold strategies) and with pattern deviation probability less than 5% (full-threshold strategy), was derived from 1000 simulated test results. The full-threshold and multisampling suprathreshold strategies had similar sensitivity to field loss. Both detected defects earlier than the conventional suprathreshold strategy. The pattern deviation probability analyses of full-threshold results underestimated the area of field loss. The conventional suprathreshold perimetry also underestimated the defect area. With multisampling suprathreshold perimetry, the estimates of defect area were less variable and exhibited lower systematic error. Multisampling suprathreshold paradigms may be a powerful alternative to other strategies of visual field testing. Clinical trials are needed to verify these findings.
Time-resolved dosimetry using a pinpoint ionization chamber as quality assurance for IMRT and VMAT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Louwe, Robert J. W., E-mail: rob.louwe@ccdbh.org.nz; Satherley, Thomas; Day, Rebecca A.
Purpose: To develop a method to verify the dose delivery in relation to the individual control points of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using an ionization chamber. In addition to more effective problem solving during patient-specific quality assurance (QA), the aim is to eventually map out the limitations in the treatment chain and enable a targeted improvement of the treatment technique in an efficient way. Methods: Pretreatment verification was carried out for 255 treatment plans that included a broad range of treatment indications in two departments using the equipment of different vendors. In-house developed softwaremore » was used to enable calculation of the dose delivery for the individual beamlets in the treatment planning system (TPS), for data acquisition, and for analysis of the data. The observed deviations were related to various delivery and measurement parameters such as gantry angle, field size, and the position of the detector with respect to the field edge to distinguish between error sources. Results: The average deviation of the integral fraction dose during pretreatment verification of the planning target volume dose was −2.1% ± 2.2% (1 SD), −1.7% ± 1.7% (1 SD), and 0.0% ± 1.3% (1 SD) for IMRT at the Radboud University Medical Center (RUMC), VMAT (RUMC), and VMAT at the Wellington Blood and Cancer Centre, respectively. Verification of the dose to organs at risk gave very similar results but was generally subject to a larger measurement uncertainty due to the position of the detector at a high dose gradient. The observed deviations could be related to limitations of the TPS beam models, attenuation of the treatment couch, as well as measurement errors. The apparent systematic error of about −2% in the average deviation of the integral fraction dose in the RUMC results could be explained by the limitations of the TPS beam model in the calculation of the beam penumbra. Conclusions: This study showed that time-resolved dosimetry using an ionization chamber is feasible and can be largely automated which limits the required additional time compared to integrated dose measurements. It provides a unique QA method which enables identification and quantification of the contribution of various error sources during IMRT and VMAT delivery.« less
Prediction uncertainty and optimal experimental design for learning dynamical systems.
Letham, Benjamin; Letham, Portia A; Rudin, Cynthia; Browne, Edward P
2016-06-01
Dynamical systems are frequently used to model biological systems. When these models are fit to data, it is necessary to ascertain the uncertainty in the model fit. Here, we present prediction deviation, a metric of uncertainty that determines the extent to which observed data have constrained the model's predictions. This is accomplished by solving an optimization problem that searches for a pair of models that each provides a good fit for the observed data, yet has maximally different predictions. We develop a method for estimating a priori the impact that additional experiments would have on the prediction deviation, allowing the experimenter to design a set of experiments that would most reduce uncertainty. We use prediction deviation to assess uncertainty in a model of interferon-alpha inhibition of viral infection, and to select a sequence of experiments that reduces this uncertainty. Finally, we prove a theoretical result which shows that prediction deviation provides bounds on the trajectories of the underlying true model. These results show that prediction deviation is a meaningful metric of uncertainty that can be used for optimal experimental design.
Civai, Claudia; Rumiati, Raffaella Ida; Rustichini, Aldo
2013-09-01
Behavior in one-shot bargaining games, like the Ultimatum Game (UG), has been interpreted as an expression of social preferences, such as inequity aversion and negative reciprocity; however, the traditional UG design limits the range of possible psychological interpretation of the results. Here, we employed three different designs for ultimatum games, finding support for a more comprehensive theory: behavior is driven by cognitive factors implementing rules such as equal splitting, speaking up for the idea that equity works as a cognitive heuristic, applicable when the environment provides no reason to behave otherwise. Instead subjects deviate from this rule when environment changes, as, for instance, when personal interest is at stake. Results show that behavior varies systematically with contextual cues, balancing the self-interest with the automatic application of the equity heuristic. Thus, the context suggests the rule to be applied in a specific situation. Copyright © 2013 Elsevier B.V. All rights reserved.
Copy number variations and genetic admixtures in three Xinjiang ethnic minority groups
Lou, Haiyi; Li, Shilin; Jin, Wenfei; Fu, Ruiqing; Lu, Dongsheng; Pan, Xinwei; Zhou, Huaigu; Ping, Yuan; Jin, Li; Xu, Shuhua
2015-01-01
Xinjiang is geographically located in central Asia, and it has played an important historical role in connecting eastern Eurasian (EEA) and western Eurasian (WEA) people. However, human population genomic studies in this region have been largely underrepresented, especially with respect to studies of copy number variations (CNVs). Here we constructed the first CNV map of the three major ethnic minority groups, the Uyghur, Kazakh and Kirgiz, using Affymetrix Genome-Wide Human SNP Array 6.0. We systematically compared the properties of CNVs we identified in the three groups with the data from representatives of EEA and WEA. The analyses indicated a typical genetic admixture pattern in all three groups with ancestries from both EEA and WEA. We also identified several CNV regions showing significant deviation of allele frequency from the expected genome-wide distribution, which might be associated with population-specific phenotypes. Our study provides the first genome-wide perspective on the CNVs of three major Xinjiang ethnic minority groups and has implications for both evolutionary and medical studies. PMID:25026903
Erosion properties of cohesive sediments in the Colorado River in Grand Canyon
Akahori, R.; Schmeeckle, M.W.; Topping, D.J.; Melis, T.S.
2008-01-01
Cohesive sediment deposits characterized by a high fraction of mud (silt plus clay) significantly affect the morphology and ecosystem of rivers. Potentially cohesive sediment samples were collected from deposits in the Colorado River in Marble and Grand Canyons. The erosion velocities of these samples were measured in a laboratory flume under varying boundary shear stresses. The non-dimensional boundary shear stress at which erosion commenced showed a systematic deviation from that of non-cohesive sediments at mud fractions greater than 0.2. An empirical relation for the boundary shear stress threshold of erosion as a function of mud fraction was proposed. The mass erosion rate was modelled using the Ariathurai-Partheniades equation. The erosion rate parameter of this equation was found to be a strong function of mud fraction. Under similar boundary shear stress and sediment supply conditions in the Colorado River, cohesive lateral eddy deposits formed of mud fractions in excess of 0.2 will erode less rapidly than non-cohesive deposits. Copyright ?? 2008 John Wiley & Sons, Ltd.
Forkey, Joseph N.; Quinlan, Margot E.; Goldman, Yale E.
2005-01-01
A new approach is presented for measuring the three-dimensional orientation of individual macromolecules using single molecule fluorescence polarization (SMFP) microscopy. The technique uses the unique polarizations of evanescent waves generated by total internal reflection to excite the dipole moment of individual fluorophores. To evaluate the new SMFP technique, single molecule orientation measurements from sparsely labeled F-actin are compared to ensemble-averaged orientation data from similarly prepared densely labeled F-actin. Standard deviations of the SMFP measurements taken at 40 ms time intervals indicate that the uncertainty for individual measurements of axial and azimuthal angles is ∼10° at 40 ms time resolution. Comparison with ensemble data shows there are no substantial systematic errors associated with the single molecule measurements. In addition to evaluating the technique, the data also provide a new measurement of the torsional rigidity of F-actin. These measurements support the smaller of two values of the torsional rigidity of F-actin previously reported. PMID:15894632
Copy number variations and genetic admixtures in three Xinjiang ethnic minority groups.
Lou, Haiyi; Li, Shilin; Jin, Wenfei; Fu, Ruiqing; Lu, Dongsheng; Pan, Xinwei; Zhou, Huaigu; Ping, Yuan; Jin, Li; Xu, Shuhua
2015-04-01
Xinjiang is geographically located in central Asia, and it has played an important historical role in connecting eastern Eurasian (EEA) and western Eurasian (WEA) people. However, human population genomic studies in this region have been largely underrepresented, especially with respect to studies of copy number variations (CNVs). Here we constructed the first CNV map of the three major ethnic minority groups, the Uyghur, Kazakh and Kirgiz, using Affymetrix Genome-Wide Human SNP Array 6.0. We systematically compared the properties of CNVs we identified in the three groups with the data from representatives of EEA and WEA. The analyses indicated a typical genetic admixture pattern in all three groups with ancestries from both EEA and WEA. We also identified several CNV regions showing significant deviation of allele frequency from the expected genome-wide distribution, which might be associated with population-specific phenotypes. Our study provides the first genome-wide perspective on the CNVs of three major Xinjiang ethnic minority groups and has implications for both evolutionary and medical studies.
Columnar organization of orientation domains in V1
NASA Astrophysics Data System (ADS)
Liedtke, Joscha; Wolf, Fred
In the primary visual cortex (V1) of primates and carnivores, the functional architecture of basic stimulus selectivities appears similar across cortical layers (Hubel & Wiesel, 1962) justifying the use of two-dimensional cortical models and disregarding organization in the third dimension. Here we show theoretically that already small deviations from an exact columnar organization lead to non-trivial three-dimensional functional structures. We extend two-dimensional random field models (Schnabel et al., 2007) to a three-dimensional cortex by keeping a typical scale in each layer and introducing a correlation length in the third, columnar dimension. We examine in detail the three-dimensional functional architecture for different cortical geometries with different columnar correlation lengths. We find that (i) topological defect lines are generally curved and (ii) for large cortical curvatures closed loops and reconnecting topological defect lines appear. This theory extends the class of random field models by introducing a columnar dimension and provides a systematic statistical assessment of the three-dimensional functional architecture of V1 (see also (Tanaka et al., 2011)).
Rose garden promises of intelligent tutoring systems: Blossom or thorn
NASA Technical Reports Server (NTRS)
Shute, Valerie J.
1991-01-01
Intelligent tutoring systems (ITS) have been in existence for over a decade. However, few controlled evaluation studies have been conducted comparing the effectiveness of these systems to more traditional instruction methods. Two main promises of ITSs are examined: (1) Engender more effective and efficient learning in relation to traditional formats; and (2) Reduce the range of learning outcome measures where a majority of individuals are elevated to high performance levels. Bloom (1984) has referred to these as the two sigma problem; to achieve two standard deviation improvements with tutoring over traditional instruction methods. Four ITSs are discussed in relation to the two promises. These tutors have undergone systematic, controlled evaluations: (1) The LISP tutor (Anderson Farrell and Sauers, 1984); (2) Smithtown (Shute and Glaser, in press); (3) Sherlock (Lesgold, Lajoie, Bunzo and Eggan, 1990); and (4) The Pascal ITS (Bonar, Cunningham, Beatty and Well, 1988). Results show that these four tutors do accelerate learning with no degradation in final outcome. Suggestions for improvements to the design and evaluation of ITSs are discussed.
Protection from sunburn with beta-Carotene--a meta-analysis.
Köpcke, Wolfgang; Krutmann, Jean
2008-01-01
Nutritional protection against skin damage from sunlight is increasingly advocated to the general public, but its effectiveness is controversial. In this meta-analysis, we have systematically reviewed the existing literature on human supplementation studies on dietary protection against sunburn by beta-carotene. A review of literature until June 2007 was performed in PubMed, ISI Web of Science and EBM Cochrane library and identified a total of seven studies which evaluated the effectiveness of beta-carotene in protection against sunburn. Data were abstracted from these studies by means of a standardized data collection protocol. The subsequent meta-analysis showed that (1) beta-carotene supplementation protects against sunburn and (2) the study duration had a significant influence on the effected size. Regression plot analysis revealed that protection required a minimum of 10 weeks of supplementation with a mean increase of the protective effect of 0.5 standard deviations with every additional month of supplementation. Thus, dietary supplementation of humans with beta-carotene provides protection against sunburn in a time-dependent manner.
A locally-blazed ant trail achieves efficient collective navigation despite limited information
Fonio, Ehud; Heyman, Yael; Boczkowski, Lucas; Gelblum, Aviram; Kosowski, Adrian; Korman, Amos; Feinerman, Ofer
2016-01-01
Any organism faces sensory and cognitive limitations which may result in maladaptive decisions. Such limitations are prominent in the context of groups where the relevant information at the individual level may not coincide with collective requirements. Here, we study the navigational decisions exhibited by Paratrechina longicornis ants as they cooperatively transport a large food item. These decisions hinge on the perception of individuals which often restricts them from providing the group with reliable directional information. We find that, to achieve efficient navigation despite partial and even misleading information, these ants employ a locally-blazed trail. This trail significantly deviates from the classical notion of an ant trail: First, instead of systematically marking the full path, ants mark short segments originating at the load. Second, the carrying team constantly loses the guiding trail. We experimentally and theoretically show that the locally-blazed trail optimally and robustly exploits useful knowledge while avoiding the pitfalls of misleading information. DOI: http://dx.doi.org/10.7554/eLife.20185.001 PMID:27815944
Extreme Right Axis Deviation in Acute Myocardial Infarction: A Hazardous Signal of Poor Prognosis.
Wang, Qingyu; Pan, Shuo; Liu, Fuqiang; Yang, Dan; Wang, Jun-Kui
2018-05-11
BACKGROUND New-onset extreme right axis deviation and right bundle branch block (RBBB) are rare during acute myocardial infarction (AMI), and has only been reported in several cases reflecting the severity of AMI. It could predict severe clinical complications and higher risks in coronary artery disease. Although there is little electrophysiological explanation, the complications are severe. They should be emphasized in newly diagnosed extreme right axis deviation and RBBB in AMI. CASE REPORT A 72-year-old male was admitted to our department with a chief complaint of intermittent retrosternal chest pain and was diagnosed with extensive anterior myocardial infarction with RBBB, by elevated myocardial enzymes and ECG. The main wave direction of QRS in lead aVR was positive and showed an extreme right axis deviation. After a month, the patient's chest distress and the RBBB vanished, but a right axis deviation still existed. The echocardiogram showed prior extensive anterior myocardial infarction (including apex myocardia) and lower LVEF. CONCLUSIONS New diagnosed RBBB and right axis deviation is uncommon and could be a useful clue to evaluate myocardial ischemia in AMI cases. This electrocardiographic marker can identify coronary artery occlusion where ST-segments are hard to evaluate, and hence, patients may benefit most from early and complete revascularization strategies such as primary angioplasty.
Assessment of Solder Joint Fatigue Life Under Realistic Service Conditions
NASA Astrophysics Data System (ADS)
Hamasha, Sa'd.; Jaradat, Younis; Qasaimeh, Awni; Obaidat, Mazin; Borgesen, Peter
2014-12-01
The behavior of lead-free solder alloys under complex loading scenarios is still not well understood. Common damage accumulation rules fail to account for strong effects of variations in cycling amplitude, and random vibration test results cannot be interpreted in terms of performance under realistic service conditions. This is a result of the effects of cycling parameters on materials properties. These effects are not yet fully understood or quantitatively predictable, preventing modeling based on parameters such as strain, work, or entropy. Depending on the actual spectrum of amplitudes, Miner's rule of linear damage accumulation has been shown to overestimate life by more than an order of magnitude, and greater errors are predicted for other combinations. Consequences may be particularly critical for so-called environmental stress screening. Damage accumulation has, however, been shown to scale with the inelastic work done, even if amplitudes vary. This and the observation of effects of loading history on subsequent work per cycle provide for a modified damage accumulation rule which allows for the prediction of life. Individual joints of four different Sn-Ag-Cu-based solder alloys (SAC305, SAC105, SAC-Ni, and SACXplus) were cycled in shear at room temperature, alternating between two different amplitudes while monitoring the evolution of the effective stiffness and work per cycle. This helped elucidate general trends and behaviors that are expected to occur in vibrations of microelectronics assemblies. Deviations from Miner's rule varied systematically with the combination of amplitudes, the sequences of cycles, and the strain rates in each. The severity of deviations also varied systematically with Ag content in the solder, but major effects were observed for all the alloys. A systematic analysis was conducted to assess whether scenarios might exist in which the more fatigue-resistant high-Ag alloys would fail sooner than the lower-Ag ones.
Measurements of {Gamma}(Z{sup O} {yields} b{bar b})/{Gamma}(Z{sup O} {yields} hadrons) using the SLD
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neal, H.A. Jr. II
1995-07-01
The quantity R{sub b} = {Gamma}(Z{sup o} {yields}b{bar b})/{Gamma}(Z{sup o} {yields} hadrons) is a sensitive measure of corrections to the Zbb vertex. The precision necessary to observe the top quark mass dependent corrections is close to being achieved. LEP is already observing a 1.8{sigma} deviation from the Standard Model prediction. Knowledge of the top quark mass combined with the observation of deviations from the Standard Model prediction would indicate new physics. Models which include charged Higgs or light SUSY particles yield predictions for R{sub b} appreciably different from the Standard Model. In this thesis two independent methods are used tomore » measure R{sub b}. One uses a general event tag which determines R{sub b} from the rate at which events are tagged as Z{sup o} {yields} b{bar b} in data and the estimated rates at which various flavors of events are tagged from the Monte Carlo. The second method reduces the reliance on the Monte Carlo by separately tagging each hemisphere as containing a b-decay. The rates of single hemisphere tagged events and both hemisphere tagged events are used to determine the tagging efficiency for b-quarks directly from the data thus eliminating the main sources of systematic error present in the event tag. Both measurements take advantage of the unique environment provided by the SLAC Linear Collider (SLC) and the SLAC Large Detector (SLD). From the event tag a result of R{sub b} = 0.230{plus_minus}0.004{sub statistical}{plus_minus}0.013{sub systematic} is obtained. The higher precision hemisphere tag result obtained is R{sub b} = 0.218{plus_minus}0.004{sub statistical}{plus_minus}0.004{sub systematic}{plus_minus}0.003{sub Rc}.« less
NASA Astrophysics Data System (ADS)
Petrishcheva, E.; Abart, R.
2012-04-01
We address mathematical modeling and computer simulations of phase decomposition in a multicomponent system. As opposed to binary alloys with one common diffusion parameter, our main concern is phase decomposition in real geological systems under influence of strongly different interdiffusion coefficients, as it is frequently encountered in mineral solid solutions with coupled diffusion on different sub-lattices. Our goal is to explain deviations from equilibrium element partitioning which are often observed in nature, e.g., in a cooled ternary feldspar. To this end we first adopt the standard Cahn-Hilliard model to the multicomponent diffusion problem and account for arbitrary diffusion coefficients. This is done by using Onsager's approach such that flux of each component results from the combined action of chemical potentials of all components. In a second step the generalized Cahn-Hilliard equation is solved numerically using finite-elements approach. We introduce and investigate several decomposition scenarios that may produce systematic deviations from the equilibrium element partitioning. Both ideal solutions and ternary feldspar are considered. Typically, the slowest component is initially "frozen" and the decomposition effectively takes place only for two "fast" components. At this stage the deviations from the equilibrium element partitioning are indeed observed. These deviations may became "frozen" under conditions of cooling. The final equilibration of the system occurs on a considerably slower time scale. Therefore the system may indeed remain unaccomplished at the observation point. Our approach reveals the intrinsic reasons for the specific phase separation path and rigorously describes it by direct numerical solution of the generalized Cahn-Hilliard equation.
Results and Systematic Studies of the UCN Lifetime Experiment at NIST
NASA Astrophysics Data System (ADS)
Huffer, Craig Reeves
The neutron beta-decay lifetime is important in understanding weak interactions in the framework of the Standard Model, and it is an input to nuclear astrophysics and Big Bang Nucleosynthesis. Current measurements of the neutron beta-decay lifetime disagree, which has motivated additional experiments that are sensitive to different sets of systematic effects. An effort continues at the NIST Center for Neutron Research (NCNR) to improve the statistical and systematic limitations of an experiment to measure the neutron beta-decay lifetime using magnetically trapped UCN. In the experiment, a monoenergetic 0:89 nm cold neutron is incident on a superfluid 4He target within the minimum field region of an Ioffe type magnetic trap. Some of the neutrons are subsequently downscattered by single phonons in the helium to low energies (≈ 200 neV), and those in the appropriate spin state become trapped. The inverse process, upscattering of UCN, is suppressed by the low phonon density in the < 300 mK helium. When the neutron decays, the energetic electron creates EUV scintillation light, which is down-converted and transported out of the cell to PMTs operated at room temperature. With this method, the decay of the UCN population can be monitored in situ. The apparatus, analysis, data, and systematics will be discussed. After accounting for the systematic effects the measured lifetime disagrees with the current PDG mean neutron beta-decay lifetime by about 9 of our standard deviations, which is a strong indication of unaccounted for systematic effects. Additional 3He contamination will be shown to be the most likely candidate for the additional systematic shift, which motivated the commissioning and initial operation of a heat flush purifier for purifying additional 4He. This work ends with a description of the 4He purifier and its performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, T. S.
Meeting the science goals for many current and future ground-based optical large-area sky surveys requires that the calibrated broadband photometry is stable in time and uniform over the sky to 1% precision or better. Past surveys have achieved photometric precision of 1-2% by calibrating the survey's stellar photometry with repeated measurements of a large number of stars observed in multiple epochs. The calibration techniques employed by these surveys only consider the relative frame-by-frame photometric zeropoint offset and the focal plane position-dependent illumination corrections, which are independent of the source color. However, variations in the wavelength dependence of the atmospheric transmissionmore » and the instrumental throughput induce source color-dependent systematic errors. These systematic errors must also be considered to achieve the most precise photometric measurements. In this paper, we examine such systematic chromatic errors using photometry from the Dark Energy Survey (DES) as an example. We define a natural magnitude system for DES and calculate the systematic errors on stellar magnitudes, when the atmospheric transmission and instrumental throughput deviate from the natural system. We conclude that the systematic chromatic errors caused by the change of airmass in each exposure, the change of the precipitable water vapor and aerosol in the atmosphere over time, and the non-uniformity of instrumental throughput over the focal plane, can be up to 2% in some bandpasses. We compare the calculated systematic chromatic errors with the observed DES data. For the test sample data, we correct these errors using measurements of the atmospheric transmission and instrumental throughput. The residual after correction is less than 0.3%. We also find that the errors for non-stellar objects are redshift-dependent and can be larger than those for stars at certain redshifts.« less
Density Large Deviations for Multidimensional Stochastic Hyperbolic Conservation Laws
NASA Astrophysics Data System (ADS)
Barré, J.; Bernardin, C.; Chetrite, R.
2018-02-01
We investigate the density large deviation function for a multidimensional conservation law in the vanishing viscosity limit, when the probability concentrates on weak solutions of a hyperbolic conservation law. When the mobility and diffusivity matrices are proportional, i.e. an Einstein-like relation is satisfied, the problem has been solved in Bellettini and Mariani (Bull Greek Math Soc 57:31-45, 2010). When this proportionality does not hold, we compute explicitly the large deviation function for a step-like density profile, and we show that the associated optimal current has a non trivial structure. We also derive a lower bound for the large deviation function, valid for a more general weak solution, and leave the general large deviation function upper bound as a conjecture.
DeSantis, Michael C; DeCenzo, Shawn H; Li, Je-Luen; Wang, Y M
2010-03-29
Standard deviation measurements of intensity profiles of stationary single fluorescent molecules are useful for studying axial localization, molecular orientation, and a fluorescence imaging system's spatial resolution. Here we report on the analysis of the precision of standard deviation measurements of intensity profiles of single fluorescent molecules imaged using an EMCCD camera.We have developed an analytical expression for the standard deviation measurement error of a single image which is a function of the total number of detected photons, the background photon noise, and the camera pixel size. The theoretical results agree well with the experimental, simulation, and numerical integration results. Using this expression, we show that single-molecule standard deviation measurements offer nanometer precision for a large range of experimental parameters.
Mattes, Richard D; Shikany, James M; Kaiser, Kathryn A; Allison, David B
2010-01-01
Nutritively sweetened beverages (NSBs) may play a role in the obesity epidemic. We abstracted data from randomized controlled trials (RCTs) and evidence-based reviews through January 2009 concerning effects of consumption of NSBs on changes in body weight and adiposity. Studies included were those 1) conducted in humans; 2) lasting at least 3 weeks; 3) incorporating random assignment of subjects to conditions that differed only in the consumption of NSBs; and 4) including an adiposity indicator as an outcome. Twelve studies met the inclusion criteria. Meta-analysis of 6 studies that added NSBs to persons’ diets showed dose-dependent increases in weight. Contrarily, meta-analysis of studies that attempted to reduce NSB consumption consistently showed no effect on BMI when all subjects were considered. Meta-analysis of studies providing access to results separately for subjects overweight at baseline showed a significant effect of a roughly 0.35 standard deviations lesser BMI change (i.e., more weight loss or less weight gain) relative to controls. The current evidence does not demonstrate conclusively that NSB consumption has uniquely contributed to obesity or that reducing NSB consumption will reduce BMI levels in general. We recommend an adequately powered RCT among overweight persons, among whom there is suggestive evidence of an effect. PMID:20524996
Comparison of ionospheric F2 peak parameters foF2 and hmF2 with IRI2001 at Hainan
NASA Astrophysics Data System (ADS)
Wang, X.; Shi, J. K.; Wang, G. J.; Gong, Y.
2009-06-01
Monthly median values of foF2, hmF2 and M(3000)F2 parameters, with quarter-hourly time interval resolution for the diurnal variation, obtained with DPS4 digisonde at Hainan (19.5°N, 109.1°E; Geomagnetic coordinates: 178.95°E, 8.1°N) are used to investigate the low-latitude ionospheric variations and comparisons with the International Reference Ionosphere (IRI) model predictions. The data used for the present study covers the period from February 2002 to April 2007, which is characterized by a wide range of solar activity, ranging from high solar activity (2002) to low solar activity (2007). The results show that (1) Generally, IRI predictions follow well the diurnal and seasonal variation patterns of the experimental values of foF2, especially in the summer of 2002. However, there are systematic deviation between experimental values and IRI predictions with either CCIR or URSI coefficients. Generally IRI model greatly underestimate the values of foF2 from about noon to sunrise of next day, especially in the afternoon, and slightly overestimate them from sunrise to about noon. It seems that there are bigger deviations between IRI Model predictions and the experimental observations for the moderate solar activity. (2) Generally the IRI-predicted hmF2 values using CCIR M(3000)F2 option shows a poor agreement with the experimental results, but there is a relatively good agreement in summer at low solar activity. The deviation between the IRI-predicted hmF2 using CCIR M(3000)F2 and observed hmF2 is bigger from noon to sunset and around sunrise especially at high solar activity. The occurrence time of hmF2 peak (about 1200 LT) of the IRI model predictions is earlier than that of observations (around 1500 LT). The agreement between the IRI hmF2 obtained with the measured M(3000)F2 and the observed hmF2 is very good except that IRI overestimates slightly hmF2 in the daytime in summer at high solar activity and underestimates it in the nighttime with lower values near sunrise at low solar activity.
Multiple sensor fault diagnosis for dynamic processes.
Li, Cheng-Chih; Jeng, Jyh-Cheng
2010-10-01
Modern industrial plants are usually large scaled and contain a great amount of sensors. Sensor fault diagnosis is crucial and necessary to process safety and optimal operation. This paper proposes a systematic approach to detect, isolate and identify multiple sensor faults for multivariate dynamic systems. The current work first defines deviation vectors for sensor observations, and further defines and derives the basic sensor fault matrix (BSFM), consisting of the normalized basic fault vectors, by several different methods. By projecting a process deviation vector to the space spanned by BSFM, this research uses a vector with the resulted weights on each direction for multiple sensor fault diagnosis. This study also proposes a novel monitoring index and derives corresponding sensor fault detectability. The study also utilizes that vector to isolate and identify multiple sensor faults, and discusses the isolatability and identifiability. Simulation examples and comparison with two conventional PCA-based contribution plots are presented to demonstrate the effectiveness of the proposed methodology. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huynh, Mioy T.; Anson, Colin W.; Cavell, Andrew C.
Quinones participate in diverse electron transfer and proton-coupled electron transfer processes in chemistry and biology. An experimental study of common quinones reveals a non-linear correlation between the 1 e – and 2 e –/2 H + reduction potentials. This unexpected observation prompted a computational study of 128 different quinones, probing their 1 e – reduction potentials, pKa values, and 2 e –/2 H + reduction potentials. The density functional theory calculations reveal an approximately linear correlation between these three properties and an effective Hammett constant associated with the quinone substituent(s). However, deviations from this linear scaling relationship are evident formore » quinones that feature halogen substituents, charged substituents, intramolecular hydrogen bonding in the hydroquinone, and/or sterically bulky substituents. These results, particularly the different substituent effects on the 1 e – versus 2 e – /2 H + reduction potentials, have important implications for designing quinones with tailored redox properties.« less
Ultimate explanations and suboptimal choice.
Vasconcelos, Marco; Machado, Armando; Pandeirada, Josefa N S
2018-07-01
Researchers have unraveled multiple cases in which behavior deviates from rationality principles. We propose that such deviations are valuable tools to understand the adaptive significance of the underpinning mechanisms. To illustrate, we discuss in detail an experimental protocol in which animals systematically incur substantial foraging losses by preferring a lean but informative option over a rich but non-informative one. To understand how adaptive mechanisms may fail to maximize food intake, we review a model inspired by optimal foraging principles that reconciles sub-optimal choice with the view that current behavioral mechanisms were pruned by the optimizing action of natural selection. To move beyond retrospective speculation, we then review critical tests of the model, regarding both its assumptions and its (sometimes counterintuitive) predictions, all of which have been upheld. The overall contention is that (a) known mechanisms can be used to develop better ultimate accounts and that (b) to understand why mechanisms that generate suboptimal behavior evolved, we need to consider their adaptive value in the animal's characteristic ecology. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Sanders, W. A.; Baaklini, G. Y.
1986-01-01
A sintered Si3N4-SiO2-Y2O3 composition, NASA 6Y, was developed that reached four-point flexural average strength/standard deviation values of 857/36, 544/33, and 462/59 MPa at room temperature, 1200 and 1370 C respectively. These strengths represented improvements of 56, 38, and 21 percent over baseline properties at the three test temperatures. At room temperature the standard deviation was reduced by over a factor of three. These accomplishments were realized by the iterative utilization of conventional x-radiography to characterize structural (density) uniformity as affected by systematic changes in powder processing and sintering parameters. Accompanying the improvement in mechanical properties was a change in the type of flaw causing failure from a pore to a large columnar beta- Si3N4 grain typically 40 to 80 microns long, 10 to 30 microns wide, and with an aspect ratio of 5:1.
Aaij, R; Adeva, B; Adinolfi, M; Ajaltouni, Z; Akar, S; Albrecht, J; Alessio, F; Alexander, M; Alfonso Albero, A; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amerio, S; Amhis, Y; An, L; Anderlini, L; Andreassi, G; Andreotti, M; Andrews, J E; Appleby, R B; Archilli, F; d'Argent, P; Arnau Romeu, J; Artamonov, A; Artuso, M; Aslanides, E; Atzeni, M; Auriemma, G; Baalouch, M; Babuschkin, I; Bachmann, S; Back, J J; Badalov, A; Baesso, C; Baker, S; Balagura, V; Baldini, W; Baranov, A; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Baryshnikov, F; Batozskaya, V; Battista, V; Bay, A; Beaucourt, L; Beddow, J; Bedeschi, F; Bediaga, I; Beiter, A; Bel, L J; Beliy, N; Bellee, V; Belloli, N; Belous, K; Belyaev, I; Ben-Haim, E; Bencivenni, G; Benson, S; Beranek, S; Berezhnoy, A; Bernet, R; Berninghoff, D; Bertholet, E; Bertolin, A; Betancourt, C; Betti, F; Bettler, M-O; van Beuzekom, M; Bezshyiko, Ia; Bifani, S; Billoir, P; Birnkraut, A; Bizzeti, A; Bjørn, M; Blake, T; Blanc, F; Blusk, S; Bocci, V; Boettcher, T; Bondar, A; Bondar, N; Bordyuzhin, I; Borghi, S; Borisyak, M; Borsato, M; Bossu, F; Boubdir, M; Bowcock, T J V; Bowen, E; Bozzi, C; Braun, S; Britton, T; Brodzicka, J; Brundu, D; Buchanan, E; Burr, C; Bursche, A; Buytaert, J; Byczynski, W; Cadeddu, S; Cai, H; Calabrese, R; Calladine, R; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Campora Perez, D H; Capriotti, L; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carniti, P; Carson, L; Carvalho Akiba, K; Casse, G; Cassina, L; Cattaneo, M; Cavallero, G; Cenci, R; Chamont, D; Chapman, M G; Charles, M; Charpentier, Ph; Chatzikonstantinidis, G; Chefdeville, M; Chen, S; Cheung, S F; Chitic, S-G; Chobanova, V; Chrzaszcz, M; Chubykin, A; Ciambrone, P; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Cogan, J; Cogneras, E; Cogoni, V; Cojocariu, L; Collins, P; Colombo, T; Comerma-Montells, A; Contu, A; Cook, A; Coombs, G; Coquereau, S; Corti, G; Corvo, M; Costa Sobral, C M; Couturier, B; Cowan, G A; Craik, D C; Crocombe, A; Cruz Torres, M; Currie, R; D'Ambrosio, C; Da Cunha Marinho, F; Dall'Occo, E; Dalseno, J; Davis, A; De Aguiar Francisco, O; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Serio, M; De Simone, P; Dean, C T; Decamp, D; Del Buono, L; Dembinski, H-P; Demmer, M; Dendek, A; Derkach, D; Deschamps, O; Dettori, F; Dey, B; Di Canto, A; Di Nezza, P; Dijkstra, H; Dordei, F; Dorigo, M; Dosil Suárez, A; Douglas, L; Dovbnya, A; Dreimanis, K; Dufour, L; Dujany, G; Durante, P; Dzhelyadin, R; Dziewiecki, M; Dziurda, A; Dzyuba, A; Easo, S; Ebert, M; Egede, U; Egorychev, V; Eidelman, S; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; Ely, S; Esen, S; Evans, H M; Evans, T; Falabella, A; Farley, N; Farry, S; Fazzini, D; Federici, L; Ferguson, D; Fernandez, G; Fernandez Declara, P; Fernandez Prieto, A; Ferrari, F; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fini, R A; Fiorini, M; Firlej, M; Fitzpatrick, C; Fiutowski, T; Fleuret, F; Fohl, K; Fontana, M; Fontanelli, F; Forshaw, D C; Forty, R; Franco Lima, V; Frank, M; Frei, C; Fu, J; Funk, W; Furfaro, E; Färber, C; Gabriel, E; Gallas Torreira, A; Galli, D; Gallorini, S; Gambetta, S; Gandelman, M; Gandini, P; Gao, Y; Garcia Martin, L M; García Pardiñas, J; Garra Tico, J; Garrido, L; Garsed, P J; Gascon, D; Gaspar, C; Gavardi, L; Gazzoni, G; Gerick, D; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gianì, S; Gibson, V; Girard, O G; Giubega, L; Gizdov, K; Gligorov, V V; Golubkov, D; Golutvin, A; Gomes, A; Gorelov, I V; Gotti, C; Govorkova, E; Grabowski, J P; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graverini, E; Graziani, G; Grecu, A; Greim, R; Griffith, P; Grillo, L; Gruber, L; Gruberg Cazon, B R; Grünberg, O; Gushchin, E; Guz, Yu; Gys, T; Göbel, C; Hadavizadeh, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hamilton, B; Han, X; Hancock, T H; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Hasse, C; Hatch, M; He, J; Hecker, M; Heinicke, K; Heister, A; Hennessy, K; Henrard, P; Henry, L; van Herwijnen, E; Heß, M; Hicheur, A; Hill, D; Hombach, C; Hopchev, P H; Hu, W; Huard, Z C; Hulsbergen, W; Humair, T; Hushchyn, M; Hutchcroft, D; Ibis, P; Idzik, M; Ilten, P; Jacobsson, R; Jalocha, J; Jans, E; Jawahery, A; Jiang, F; John, M; Johnson, D; Jones, C R; Joram, C; Jost, B; Jurik, N; Kandybei, S; Karacson, M; Kariuki, J M; Karodia, S; Kazeev, N; Kecke, M; Keizer, F; Kelsey, M; Kenzie, M; Ketel, T; Khairullin, E; Khanji, B; Khurewathanakul, C; Kirn, T; Klaver, S; Klimaszewski, K; Klimkovich, T; Koliiev, S; Kolpin, M; Kopecna, R; Koppenburg, P; Kosmyntseva, A; Kotriakhova, S; Kozeiha, M; Kravchuk, L; Kreps, M; Kress, F; Krokovny, P; Kruse, F; Krzemien, W; Kucewicz, W; Kucharczyk, M; Kudryavtsev, V; Kuonen, A K; Kvaratskheliya, T; Lacarrere, D; Lafferty, G; Lai, A; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; Leflat, A; Lefrançois, J; Lefèvre, R; Lemaitre, F; Lemos Cid, E; Leroy, O; Lesiak, T; Leverington, B; Li, P-R; Li, T; Li, Y; Li, Z; Likhomanenko, T; Lindner, R; Lionetto, F; Lisovskyi, V; Liu, X; Loh, D; Loi, A; Longstaff, I; Lopes, J H; Lucchesi, D; Lucio Martinez, M; Luo, H; Lupato, A; Luppi, E; Lupton, O; Lusiani, A; Lyu, X; Machefert, F; Maciuc, F; Macko, V; Mackowiak, P; Maddrell-Mander, S; Maev, O; Maguire, K; Maisuzenko, D; Majewski, M W; Malde, S; Malecki, B; Malinin, A; Maltsev, T; Manca, G; Mancinelli, G; Marangotto, D; Maratas, J; Marchand, J F; Marconi, U; Marin Benito, C; Marinangeli, M; Marino, P; Marks, J; Martellotti, G; Martin, M; Martinelli, M; Martinez Santos, D; Martinez Vidal, F; Massacrier, L M; Massafferri, A; Matev, R; Mathad, A; Mathe, Z; Matteuzzi, C; Mauri, A; Maurice, E; Maurin, B; Mazurov, A; McCann, M; McNab, A; McNulty, R; Mead, J V; Meadows, B; Meaux, C; Meier, F; Meinert, N; Melnychuk, D; Merk, M; Merli, A; Michielin, E; Milanes, D A; Millard, E; Minard, M-N; Minzoni, L; Mitzel, D S; Mogini, A; Molina Rodriguez, J; Mombächer, T; Monroy, I A; Monteil, S; Morandin, M; Morello, M J; Morgunova, O; Moron, J; Morris, A B; Mountain, R; Muheim, F; Mulder, M; Müller, D; Müller, J; Müller, K; Müller, V; Naik, P; Nakada, T; Nandakumar, R; Nandi, A; Nasteva, I; Needham, M; Neri, N; Neubert, S; Neufeld, N; Neuner, M; Nguyen, T D; Nguyen-Mau, C; Nieswand, S; Niet, R; Nikitin, N; Nikodem, T; Nogay, A; O'Hanlon, D P; Oblakowska-Mucha, A; Obraztsov, V; Ogilvy, S; Oldeman, R; Onderwater, C J G; Ossowska, A; Otalora Goicochea, J M; Owen, P; Oyanguren, A; Pais, P R; Palano, A; Palutan, M; Papanestis, A; Pappagallo, M; Pappalardo, L L; Parker, W; Parkes, C; Passaleva, G; Pastore, A; Patel, M; Patrignani, C; Pearce, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perret, P; Pescatore, L; Petridis, K; Petrolini, A; Petrov, A; Petruzzo, M; Picatoste Olloqui, E; Pietrzyk, B; Pikies, M; Pinci, D; Pisani, F; Pistone, A; Piucci, A; Placinta, V; Playfer, S; Plo Casasus, M; Polci, F; Poli Lener, M; Poluektov, A; Polyakov, I; Polycarpo, E; Pomery, G J; Ponce, S; Popov, A; Popov, D; Poslavskii, S; Potterat, C; Price, E; Prisciandaro, J; Prouve, C; Pugatch, V; Puig Navarro, A; Pullen, H; Punzi, G; Qian, W; Quagliani, R; Quintana, B; Rachwal, B; Rademacker, J H; Rama, M; Ramos Pernas, M; Rangel, M S; Raniuk, I; Ratnikov, F; Raven, G; Ravonel Salzgeber, M; Reboud, M; Redi, F; Reichert, S; Dos Reis, A C; Remon Alepuz, C; Renaudin, V; Ricciardi, S; Richards, S; Rihl, M; Rinnert, K; Rives Molina, V; Robbe, P; Robert, A; Rodrigues, A B; Rodrigues, E; Rodriguez Lopez, J A; Rogozhnikov, A; Roiser, S; Rollings, A; Romanovskiy, V; Romero Vidal, A; Ronayne, J W; Rotondo, M; Rudolph, M S; Ruf, T; Ruiz Valls, P; Ruiz Vidal, J; Saborido Silva, J J; Sadykhov, E; Sagidova, N; Saitta, B; Salustino Guimaraes, V; Sanchez Mayordomo, C; Sanmartin Sedes, B; Santacesaria, R; Santamarina Rios, C; Santimaria, M; Santovetti, E; Sarpis, G; Sarti, A; Satriano, C; Satta, A; Saunders, D M; Savrina, D; Schael, S; Schellenberg, M; Schiller, M; Schindler, H; Schmelling, M; Schmelzer, T; Schmidt, B; Schneider, O; Schopper, A; Schreiner, H F; Schubiger, M; Schune, M-H; Schwemmer, R; Sciascia, B; Sciubba, A; Semennikov, A; Sepulveda, E S; Sergi, A; Serra, N; Serrano, J; Sestini, L; Seyfert, P; Shapkin, M; Shapoval, I; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, V; Siddi, B G; Silva Coutinho, R; Silva de Oliveira, L; Simi, G; Simone, S; Sirendi, M; Skidmore, N; Skwarnicki, T; Smith, E; Smith, I T; Smith, J; Smith, M; Soares Lavra, L; Sokoloff, M D; Soler, F J P; Souza De Paula, B; Spaan, B; Spradlin, P; Sridharan, S; Stagni, F; Stahl, M; Stahl, S; Stefko, P; Stefkova, S; Steinkamp, O; Stemmle, S; Stenyakin, O; Stepanova, M; Stevens, H; Stone, S; Storaci, B; Stracka, S; Stramaglia, M E; Straticiuc, M; Straumann, U; Sun, J; Sun, L; Sutcliffe, W; Swientek, K; Syropoulos, V; Szumlak, T; Szymanski, M; T'Jampens, S; Tayduganov, A; Tekampe, T; Tellarini, G; Teubert, F; Thomas, E; van Tilburg, J; Tilley, M J; Tisserand, V; Tobin, M; Tolk, S; Tomassetti, L; Tonelli, D; Toriello, F; Tourinho Jadallah Aoude, R; Tournefier, E; Traill, M; Tran, M T; Tresch, M; Trisovic, A; Tsaregorodtsev, A; Tsopelas, P; Tully, A; Tuning, N; Ukleja, A; Usachov, A; Ustyuzhanin, A; Uwer, U; Vacca, C; Vagner, A; Vagnoni, V; Valassi, A; Valat, S; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; van Veghel, M; Velthuis, J J; Veltri, M; Veneziano, G; Venkateswaran, A; Verlage, T A; Vernet, M; Vesterinen, M; Viana Barbosa, J V; Viaud, B; Vieira, D; Vieites Diaz, M; Viemann, H; Vilasis-Cardona, X; Vitti, M; Volkov, V; Vollhardt, A; Voneki, B; Vorobyev, A; Vorobyev, V; Voß, C; de Vries, J A; Vázquez Sierra, C; Waldi, R; Wallace, C; Wallace, R; Walsh, J; Wang, J; Ward, D R; Wark, H M; Watson, N K; Websdale, D; Weiden, A; Weisser, C; Whitehead, M; Wicht, J; Wilkinson, G; Wilkinson, M; Williams, M; Williams, M P; Williams, M; Williams, T; Wilson, F F; Wimberley, J; Winn, M; Wishahi, J; Wislicki, W; Witek, M; Wormser, G; Wotton, S A; Wraight, K; Wyllie, K; Xie, Y; Xu, M; Xu, Z; Yang, Z; Yang, Z; Yao, Y; Yin, H; Yu, J; Yuan, X; Yushchenko, O; Zarebski, K A; Zavertyaev, M; Zhang, L; Zhang, Y; Zhelezov, A; Zheng, Y; Zhu, X; Zhukov, V; Zonneveld, J B; Zucchelli, S
2018-03-23
A measurement is reported of the ratio of branching fractions R(J/ψ)=B(B_{c}^{+}→J/ψτ^{+}ν_{τ})/B(B_{c}^{+}→J/ψμ^{+}ν_{μ}), where the τ^{+} lepton is identified in the decay mode τ^{+}→μ^{+}ν_{μ}ν[over ¯]_{τ}. This analysis uses a sample of proton-proton collision data corresponding to 3.0 fb^{-1} of integrated luminosity recorded with the LHCb experiment at center-of-mass energies of 7 and 8 TeV. A signal is found for the decay B_{c}^{+}→J/ψτ^{+}ν_{τ} at a significance of 3 standard deviations corrected for systematic uncertainty, and the ratio of the branching fractions is measured to be R(J/ψ)=0.71±0.17(stat)±0.18(syst). This result lies within 2 standard deviations above the range of central values currently predicted by the standard model.
Measurement of the Ratio of Branching Fractions B (Bc+→J /ψ τ+ντ)/B (Bc+→J /ψ μ+νμ)
NASA Astrophysics Data System (ADS)
Aaij, R.; Adeva, B.; Adinolfi, M.; Ajaltouni, Z.; Akar, S.; Albrecht, J.; Alessio, F.; Alexander, M.; Alfonso Albero, A.; Ali, S.; Alkhazov, G.; Alvarez Cartelle, P.; Alves, A. A.; Amato, S.; Amerio, S.; Amhis, Y.; An, L.; Anderlini, L.; Andreassi, G.; Andreotti, M.; Andrews, J. E.; Appleby, R. B.; Archilli, F.; d'Argent, P.; Arnau Romeu, J.; Artamonov, A.; Artuso, M.; Aslanides, E.; Atzeni, M.; Auriemma, G.; Baalouch, M.; Babuschkin, I.; Bachmann, S.; Back, J. J.; Badalov, A.; Baesso, C.; Baker, S.; Balagura, V.; Baldini, W.; Baranov, A.; Barlow, R. J.; Barschel, C.; Barsuk, S.; Barter, W.; Baryshnikov, F.; Batozskaya, V.; Battista, V.; Bay, A.; Beaucourt, L.; Beddow, J.; Bedeschi, F.; Bediaga, I.; Beiter, A.; Bel, L. J.; Beliy, N.; Bellee, V.; Belloli, N.; Belous, K.; Belyaev, I.; Ben-Haim, E.; Bencivenni, G.; Benson, S.; Beranek, S.; Berezhnoy, A.; Bernet, R.; Berninghoff, D.; Bertholet, E.; Bertolin, A.; Betancourt, C.; Betti, F.; Bettler, M.-O.; van Beuzekom, M.; Bezshyiko, Ia.; Bifani, S.; Billoir, P.; Birnkraut, A.; Bizzeti, A.; Bjørn, M.; Blake, T.; Blanc, F.; Blusk, S.; Bocci, V.; Boettcher, T.; Bondar, A.; Bondar, N.; Bordyuzhin, I.; Borghi, S.; Borisyak, M.; Borsato, M.; Bossu, F.; Boubdir, M.; Bowcock, T. J. V.; Bowen, E.; Bozzi, C.; Braun, S.; Britton, T.; Brodzicka, J.; Brundu, D.; Buchanan, E.; Burr, C.; Bursche, A.; Buytaert, J.; Byczynski, W.; Cadeddu, S.; Cai, H.; Calabrese, R.; Calladine, R.; Calvi, M.; Calvo Gomez, M.; Camboni, A.; Campana, P.; Campora Perez, D. H.; Capriotti, L.; Carbone, A.; Carboni, G.; Cardinale, R.; Cardini, A.; Carniti, P.; Carson, L.; Carvalho Akiba, K.; Casse, G.; Cassina, L.; Cattaneo, M.; Cavallero, G.; Cenci, R.; Chamont, D.; Chapman, M. G.; Charles, M.; Charpentier, Ph.; Chatzikonstantinidis, G.; Chefdeville, M.; Chen, S.; Cheung, S. F.; Chitic, S.-G.; Chobanova, V.; Chrzaszcz, M.; Chubykin, A.; Ciambrone, P.; Cid Vidal, X.; Ciezarek, G.; Clarke, P. E. L.; Clemencic, M.; Cliff, H. V.; Closier, J.; Cogan, J.; Cogneras, E.; Cogoni, V.; Cojocariu, L.; Collins, P.; Colombo, T.; Comerma-Montells, A.; Contu, A.; Cook, A.; Coombs, G.; Coquereau, S.; Corti, G.; Corvo, M.; Costa Sobral, C. M.; Couturier, B.; Cowan, G. A.; Craik, D. C.; Crocombe, A.; Cruz Torres, M.; Currie, R.; D'Ambrosio, C.; Da Cunha Marinho, F.; Dall'Occo, E.; Dalseno, J.; Davis, A.; De Aguiar Francisco, O.; De Bruyn, K.; De Capua, S.; De Cian, M.; De Miranda, J. M.; De Paula, L.; De Serio, M.; De Simone, P.; Dean, C. T.; Decamp, D.; Del Buono, L.; Dembinski, H.-P.; Demmer, M.; Dendek, A.; Derkach, D.; Deschamps, O.; Dettori, F.; Dey, B.; Di Canto, A.; Di Nezza, P.; Dijkstra, H.; Dordei, F.; Dorigo, M.; Dosil Suárez, A.; Douglas, L.; Dovbnya, A.; Dreimanis, K.; Dufour, L.; Dujany, G.; Durante, P.; Dzhelyadin, R.; Dziewiecki, M.; Dziurda, A.; Dzyuba, A.; Easo, S.; Ebert, M.; Egede, U.; Egorychev, V.; Eidelman, S.; Eisenhardt, S.; Eitschberger, U.; Ekelhof, R.; Eklund, L.; Ely, S.; Esen, S.; Evans, H. M.; Evans, T.; Falabella, A.; Farley, N.; Farry, S.; Fazzini, D.; Federici, L.; Ferguson, D.; Fernandez, G.; Fernandez Declara, P.; Fernandez Prieto, A.; Ferrari, F.; Ferreira Rodrigues, F.; Ferro-Luzzi, M.; Filippov, S.; Fini, R. A.; Fiorini, M.; Firlej, M.; Fitzpatrick, C.; Fiutowski, T.; Fleuret, F.; Fohl, K.; Fontana, M.; Fontanelli, F.; Forshaw, D. C.; Forty, R.; Franco Lima, V.; Frank, M.; Frei, C.; Fu, J.; Funk, W.; Furfaro, E.; Färber, C.; Gabriel, E.; Gallas Torreira, A.; Galli, D.; Gallorini, S.; Gambetta, S.; Gandelman, M.; Gandini, P.; Gao, Y.; Garcia Martin, L. M.; García Pardiñas, J.; Garra Tico, J.; Garrido, L.; Garsed, P. J.; Gascon, D.; Gaspar, C.; Gavardi, L.; Gazzoni, G.; Gerick, D.; Gersabeck, E.; Gersabeck, M.; Gershon, T.; Ghez, Ph.; Gianı, S.; Gibson, V.; Girard, O. G.; Giubega, L.; Gizdov, K.; Gligorov, V. V.; Golubkov, D.; Golutvin, A.; Gomes, A.; Gorelov, I. V.; Gotti, C.; Govorkova, E.; Grabowski, J. P.; Graciani Diaz, R.; Granado Cardoso, L. A.; Graugés, E.; Graverini, E.; Graziani, G.; Grecu, A.; Greim, R.; Griffith, P.; Grillo, L.; Gruber, L.; Gruberg Cazon, B. R.; Grünberg, O.; Gushchin, E.; Guz, Yu.; Gys, T.; Göbel, C.; Hadavizadeh, T.; Hadjivasiliou, C.; Haefeli, G.; Haen, C.; Haines, S. C.; Hamilton, B.; Han, X.; Hancock, T. H.; Hansmann-Menzemer, S.; Harnew, N.; Harnew, S. T.; Hasse, C.; Hatch, M.; He, J.; Hecker, M.; Heinicke, K.; Heister, A.; Hennessy, K.; Henrard, P.; Henry, L.; van Herwijnen, E.; Heß, M.; Hicheur, A.; Hill, D.; Hombach, C.; Hopchev, P. H.; Hu, W.; Huard, Z. C.; Hulsbergen, W.; Humair, T.; Hushchyn, M.; Hutchcroft, D.; Ibis, P.; Idzik, M.; Ilten, P.; Jacobsson, R.; Jalocha, J.; Jans, E.; Jawahery, A.; Jiang, F.; John, M.; Johnson, D.; Jones, C. R.; Joram, C.; Jost, B.; Jurik, N.; Kandybei, S.; Karacson, M.; Kariuki, J. M.; Karodia, S.; Kazeev, N.; Kecke, M.; Keizer, F.; Kelsey, M.; Kenzie, M.; Ketel, T.; Khairullin, E.; Khanji, B.; Khurewathanakul, C.; Kirn, T.; Klaver, S.; Klimaszewski, K.; Klimkovich, T.; Koliiev, S.; Kolpin, M.; Kopecna, R.; Koppenburg, P.; Kosmyntseva, A.; Kotriakhova, S.; Kozeiha, M.; Kravchuk, L.; Kreps, M.; Kress, F.; Krokovny, P.; Kruse, F.; Krzemien, W.; Kucewicz, W.; Kucharczyk, M.; Kudryavtsev, V.; Kuonen, A. K.; Kvaratskheliya, T.; Lacarrere, D.; Lafferty, G.; Lai, A.; Lanfranchi, G.; Langenbruch, C.; Latham, T.; Lazzeroni, C.; Le Gac, R.; Leflat, A.; Lefrançois, J.; Lefèvre, R.; Lemaitre, F.; Lemos Cid, E.; Leroy, O.; Lesiak, T.; Leverington, B.; Li, P.-R.; Li, T.; Li, Y.; Li, Z.; Likhomanenko, T.; Lindner, R.; Lionetto, F.; Lisovskyi, V.; Liu, X.; Loh, D.; Loi, A.; Longstaff, I.; Lopes, J. H.; Lucchesi, D.; Lucio Martinez, M.; Luo, H.; Lupato, A.; Luppi, E.; Lupton, O.; Lusiani, A.; Lyu, X.; Machefert, F.; Maciuc, F.; Macko, V.; Mackowiak, P.; Maddrell-Mander, S.; Maev, O.; Maguire, K.; Maisuzenko, D.; Majewski, M. W.; Malde, S.; Malecki, B.; Malinin, A.; Maltsev, T.; Manca, G.; Mancinelli, G.; Marangotto, D.; Maratas, J.; Marchand, J. F.; Marconi, U.; Marin Benito, C.; Marinangeli, M.; Marino, P.; Marks, J.; Martellotti, G.; Martin, M.; Martinelli, M.; Martinez Santos, D.; Martinez Vidal, F.; Massacrier, L. M.; Massafferri, A.; Matev, R.; Mathad, A.; Mathe, Z.; Matteuzzi, C.; Mauri, A.; Maurice, E.; Maurin, B.; Mazurov, A.; McCann, M.; McNab, A.; McNulty, R.; Mead, J. V.; Meadows, B.; Meaux, C.; Meier, F.; Meinert, N.; Melnychuk, D.; Merk, M.; Merli, A.; Michielin, E.; Milanes, D. A.; Millard, E.; Minard, M.-N.; Minzoni, L.; Mitzel, D. S.; Mogini, A.; Molina Rodriguez, J.; Mombächer, T.; Monroy, I. A.; Monteil, S.; Morandin, M.; Morello, M. J.; Morgunova, O.; Moron, J.; Morris, A. B.; Mountain, R.; Muheim, F.; Mulder, M.; Müller, D.; Müller, J.; Müller, K.; Müller, V.; Naik, P.; Nakada, T.; Nandakumar, R.; Nandi, A.; Nasteva, I.; Needham, M.; Neri, N.; Neubert, S.; Neufeld, N.; Neuner, M.; Nguyen, T. D.; Nguyen-Mau, C.; Nieswand, S.; Niet, R.; Nikitin, N.; Nikodem, T.; Nogay, A.; O'Hanlon, D. P.; Oblakowska-Mucha, A.; Obraztsov, V.; Ogilvy, S.; Oldeman, R.; Onderwater, C. J. G.; Ossowska, A.; Otalora Goicochea, J. M.; Owen, P.; Oyanguren, A.; Pais, P. R.; Palano, A.; Palutan, M.; Papanestis, A.; Pappagallo, M.; Pappalardo, L. L.; Parker, W.; Parkes, C.; Passaleva, G.; Pastore, A.; Patel, M.; Patrignani, C.; Pearce, A.; Pellegrino, A.; Penso, G.; Pepe Altarelli, M.; Perazzini, S.; Perret, P.; Pescatore, L.; Petridis, K.; Petrolini, A.; Petrov, A.; Petruzzo, M.; Picatoste Olloqui, E.; Pietrzyk, B.; Pikies, M.; Pinci, D.; Pisani, F.; Pistone, A.; Piucci, A.; Placinta, V.; Playfer, S.; Plo Casasus, M.; Polci, F.; Poli Lener, M.; Poluektov, A.; Polyakov, I.; Polycarpo, E.; Pomery, G. J.; Ponce, S.; Popov, A.; Popov, D.; Poslavskii, S.; Potterat, C.; Price, E.; Prisciandaro, J.; Prouve, C.; Pugatch, V.; Puig Navarro, A.; Pullen, H.; Punzi, G.; Qian, W.; Quagliani, R.; Quintana, B.; Rachwal, B.; Rademacker, J. H.; Rama, M.; Ramos Pernas, M.; Rangel, M. S.; Raniuk, I.; Ratnikov, F.; Raven, G.; Ravonel Salzgeber, M.; Reboud, M.; Redi, F.; Reichert, S.; dos Reis, A. C.; Remon Alepuz, C.; Renaudin, V.; Ricciardi, S.; Richards, S.; Rihl, M.; Rinnert, K.; Rives Molina, V.; Robbe, P.; Robert, A.; Rodrigues, A. B.; Rodrigues, E.; Rodriguez Lopez, J. A.; Rogozhnikov, A.; Roiser, S.; Rollings, A.; Romanovskiy, V.; Romero Vidal, A.; Ronayne, J. W.; Rotondo, M.; Rudolph, M. S.; Ruf, T.; Ruiz Valls, P.; Ruiz Vidal, J.; Saborido Silva, J. J.; Sadykhov, E.; Sagidova, N.; Saitta, B.; Salustino Guimaraes, V.; Sanchez Mayordomo, C.; Sanmartin Sedes, B.; Santacesaria, R.; Santamarina Rios, C.; Santimaria, M.; Santovetti, E.; Sarpis, G.; Sarti, A.; Satriano, C.; Satta, A.; Saunders, D. M.; Savrina, D.; Schael, S.; Schellenberg, M.; Schiller, M.; Schindler, H.; Schmelling, M.; Schmelzer, T.; Schmidt, B.; Schneider, O.; Schopper, A.; Schreiner, H. F.; Schubiger, M.; Schune, M.-H.; Schwemmer, R.; Sciascia, B.; Sciubba, A.; Semennikov, A.; Sepulveda, E. S.; Sergi, A.; Serra, N.; Serrano, J.; Sestini, L.; Seyfert, P.; Shapkin, M.; Shapoval, I.; Shcheglov, Y.; Shears, T.; Shekhtman, L.; Shevchenko, V.; Siddi, B. G.; Silva Coutinho, R.; Silva de Oliveira, L.; Simi, G.; Simone, S.; Sirendi, M.; Skidmore, N.; Skwarnicki, T.; Smith, E.; Smith, I. T.; Smith, J.; Smith, M.; Soares Lavra, l.; Sokoloff, M. D.; Soler, F. J. P.; Souza De Paula, B.; Spaan, B.; Spradlin, P.; Sridharan, S.; Stagni, F.; Stahl, M.; Stahl, S.; Stefko, P.; Stefkova, S.; Steinkamp, O.; Stemmle, S.; Stenyakin, O.; Stepanova, M.; Stevens, H.; Stone, S.; Storaci, B.; Stracka, S.; Stramaglia, M. E.; Straticiuc, M.; Straumann, U.; Sun, J.; Sun, L.; Sutcliffe, W.; Swientek, K.; Syropoulos, V.; Szumlak, T.; Szymanski, M.; T'Jampens, S.; Tayduganov, A.; Tekampe, T.; Tellarini, G.; Teubert, F.; Thomas, E.; van Tilburg, J.; Tilley, M. J.; Tisserand, V.; Tobin, M.; Tolk, S.; Tomassetti, L.; Tonelli, D.; Toriello, F.; Tourinho Jadallah Aoude, R.; Tournefier, E.; Traill, M.; Tran, M. T.; Tresch, M.; Trisovic, A.; Tsaregorodtsev, A.; Tsopelas, P.; Tully, A.; Tuning, N.; Ukleja, A.; Usachov, A.; Ustyuzhanin, A.; Uwer, U.; Vacca, C.; Vagner, A.; Vagnoni, V.; Valassi, A.; Valat, S.; Valenti, G.; Vazquez Gomez, R.; Vazquez Regueiro, P.; Vecchi, S.; van Veghel, M.; Velthuis, J. J.; Veltri, M.; Veneziano, G.; Venkateswaran, A.; Verlage, T. A.; Vernet, M.; Vesterinen, M.; Viana Barbosa, J. V.; Viaud, B.; Vieira, D.; Vieites Diaz, M.; Viemann, H.; Vilasis-Cardona, X.; Vitti, M.; Volkov, V.; Vollhardt, A.; Voneki, B.; Vorobyev, A.; Vorobyev, V.; Voß, C.; de Vries, J. A.; Vázquez Sierra, C.; Waldi, R.; Wallace, C.; Wallace, R.; Walsh, J.; Wang, J.; Ward, D. R.; Wark, H. M.; Watson, N. K.; Websdale, D.; Weiden, A.; Weisser, C.; Whitehead, M.; Wicht, J.; Wilkinson, G.; Wilkinson, M.; Williams, M.; Williams, M. P.; Williams, M.; Williams, T.; Wilson, F. F.; Wimberley, J.; Winn, M.; Wishahi, J.; Wislicki, W.; Witek, M.; Wormser, G.; Wotton, S. A.; Wraight, K.; Wyllie, K.; Xie, Y.; Xu, M.; Xu, Z.; Yang, Z.; Yang, Z.; Yao, Y.; Yin, H.; Yu, J.; Yuan, X.; Yushchenko, O.; Zarebski, K. A.; Zavertyaev, M.; Zhang, L.; Zhang, Y.; Zhelezov, A.; Zheng, Y.; Zhu, X.; Zhukov, V.; Zonneveld, J. B.; Zucchelli, S.; LHCb Collaboration
2018-03-01
A measurement is reported of the ratio of branching fractions R (J /ψ ) =B (Bc+→J /ψ τ+ντ)/B (Bc+→J /ψ μ+νμ) , where the τ+ lepton is identified in the decay mode τ+→μ+νμν¯τ. This analysis uses a sample of proton-proton collision data corresponding to 3.0 fb-1 of integrated luminosity recorded with the LHCb experiment at center-of-mass energies of 7 and 8 TeV. A signal is found for the decay Bc+→J /ψ τ+ντ at a significance of 3 standard deviations corrected for systematic uncertainty, and the ratio of the branching fractions is measured to be R (J /ψ ) =0.71 ±0.17 (stat ) ±0.18 (syst ) . This result lies within 2 standard deviations above the range of central values currently predicted by the standard model.
Lithologic mapping of silicate rocks using TIMS
NASA Technical Reports Server (NTRS)
Gillespie, A. R.
1986-01-01
Common rock-forming minerals have thermal infrared spectral features that are measured in the laboratory to infer composition. An airborne Daedalus scanner (TIMS) that collects six channels of thermal infrared radiance data (8 to 12 microns), may be used to measure these same features for rock identification. Previously, false-color composite pictures made from channels 1, 3, and 5 and emittance spectra for small areas on these images were used to make lithologic maps. Central wavelength, standard deviation, and amplitude of normal curves regressed on the emittance spectra are related to compositional information for crystalline igneous silicate rocks. As expected, the central wavelength varies systematically with silica content and with modal quartz content. Standard deviation is less sensitive to compositional changes, but large values may result from mixed admixture of vegetation. Compression of the six TIMS channels to three image channels made from the regressed parameters may be effective in improving geologic mapping from TIMS data, and these synthetic images may form a basis for the remote assessment of rock composition.
Husak, G.J.; Marshall, M. T.; Michaelsen, J.; Pedreros, Diego; Funk, Christopher C.; Galu, G.
2008-01-01
Reliable estimates of cropped area (CA) in developing countries with chronic food shortages are essential for emergency relief and the design of appropriate market-based food security programs. Satellite interpretation of CA is an effective alternative to extensive and costly field surveys, which fail to represent the spatial heterogeneity at the country-level. Bias-corrected, texture based classifications show little deviation from actual crop inventories, when estimates derived from aerial photographs or field measurements are used to remove systematic errors in medium resolution estimates. In this paper, we demonstrate a hybrid high-medium resolution technique for Central Ethiopia that combines spatially limited unbiased estimates from IKONOS images, with spatially extensive Landsat ETM+ interpretations, land-cover, and SRTM-based topography. Logistic regression is used to derive the probability of a location being crop. These individual points are then aggregated to produce regional estimates of CA. District-level analysis of Landsat based estimates showed CA totals which supported the estimates of the Bureau of Agriculture and Rural Development. Continued work will evaluate the technique in other parts of Africa, while segmentation algorithms will be evaluated, in order to automate classification of medium resolution imagery for routine CA estimation in the future.
Effects of Systemic Therapy on Mental Health of Children and Adolescents: A Meta-Analysis.
Riedinger, Verena; Pinquart, Martin; Teubert, Daniela
2017-01-01
Systemic therapy is a frequently used form of psychotherapy for the treatment of mental disorders in children and adolescents. The present study reports the results of the first meta-analysis on the effects of systemic treatment of mental disorders and behavior problems in children and adolescents. Based on systematic search in electronic databases (PsycINFO, Psyndex, PubMed, ISI Web of Knowledge, CINAHL), k = 56 randomized, controlled trials met the inclusion criteria. We computed a random-effects meta-analysis. Systemic therapy showed small-to-medium effects in comparison with an untreated control group (posttest: k = 7, g = .59 standard deviation units, follow-up: k = 2, g = .27) and alternative treatment (posttest: k = 43, g = .32, follow-up: k = 38, g = .28). At follow-up, longer interventions produced larger effect sizes. No other moderator effects were identified. Although available randomized, controlled trials show convincing results, their effects refer to a limited number of systemic approaches and mental disorders, and also pertain to adolescents rather than younger children. Thus, more research is needed before more general conclusions about the effects of systemic therapy can be drawn.
Microstructure Evolution and Composition Control During the Processing of Thin-Gage Metallic Foil
NASA Astrophysics Data System (ADS)
Semiatin, S. L.; Gross, M. E.; Matson, D. W.; Bennett, W. D.; Bonham, C. C.; Ustinov, A. I.; Ballard, D. L.
2012-12-01
The manufacture of thin-gage superalloy and gamma-titanium-aluminide foil products via near-conventional thermomechanical processing and two different vapor-deposition methods was investigated. Thermomechanical processing was based on hot-pack rolling of plate and sheet. Foils of the superalloy LSHR and the near-gamma titanium aluminide Ti-45.5Al-2Cr-2Nb made by this approach exhibited excellent gage control and fine two-phase microstructures. The vapor-phase techniques used magnetron sputtering (MS) of a target of the desired product composition or electron-beam physical vapor deposition (EBPVD) of separate targets of the specific alloying elements. Thin deposits of LSHR and Ti-48Al-2Cr-2Nb made by MS showed uniform thickness/composition and an ultrafine microstructure. However, systematic deviations from the specific target composition were found. During subsequent heat treatment, the microstructure of the MS samples showed various degrees of grain growth and coarsening. Foils of Ti-43Al and Ti-51Al-1V fabricated by EBPVD were fully dense. The microstructures developed during EBPVD were interpreted in terms of measured phase equilibria and the dependence of evaporant flux on temperature.
NASA Astrophysics Data System (ADS)
Husak, G. J.; Marshall, M. T.; Michaelsen, J.; Pedreros, D.; Funk, C.; Galu, G.
2008-07-01
Reliable estimates of cropped area (CA) in developing countries with chronic food shortages are essential for emergency relief and the design of appropriate market-based food security programs. Satellite interpretation of CA is an effective alternative to extensive and costly field surveys, which fail to represent the spatial heterogeneity at the country-level. Bias-corrected, texture based classifications show little deviation from actual crop inventories, when estimates derived from aerial photographs or field measurements are used to remove systematic errors in medium resolution estimates. In this paper, we demonstrate a hybrid high-medium resolution technique for Central Ethiopia that combines spatially limited unbiased estimates from IKONOS images, with spatially extensive Landsat ETM+ interpretations, land-cover, and SRTM-based topography. Logistic regression is used to derive the probability of a location being crop. These individual points are then aggregated to produce regional estimates of CA. District-level analysis of Landsat based estimates showed CA totals which supported the estimates of the Bureau of Agriculture and Rural Development. Continued work will evaluate the technique in other parts of Africa, while segmentation algorithms will be evaluated, in order to automate classification of medium resolution imagery for routine CA estimation in the future.
Spatial judgments in the horizontal and vertical planes from different vantage points.
Prytz, Erik; Scerbo, Mark W
2012-01-01
Todorović (2008 Perception 37 106-125) reported that there are systematic errors in the perception of 3-D space when viewing 2-D linear perspective drawings depending on the observer's vantage point. Because these findings were restricted to the horizontal plane, the current study was designed to determine the nature of these errors in the vertical plane. Participants viewed an image containing multiple colonnades aligned on parallel converging lines receding to a vanishing point. They were asked to judge where, in the physical room, the next column should be placed. The results support Todorović in that systematic deviations in the spatial judgments depended on vantage point for both the horizontal and vertical planes. However, there are also marked differences between the two planes. While judgments in both planes failed to compensate adequately for the vantage-point shift, the vertical plane induced greater distortions of the stimulus image itself within each vantage point.
Self-care and HIV/AIDS patients: nursing care systematization.
Caetano, Joselany Afio; Pagliuca, Lorita Marlena Freitag
2006-01-01
This research aimed at systematizing nursing care to HIV/aids patients in view of Orem's Self-care Deficit Nursing Theory, using the convergent-care method and the Self-Care Nursing Process. Subjects were thirteen HIV/AIDS patients attended at a non-governmental organization in Fortaleza/CE, Brazil. We used interview techniques, physical examination, observation and information records, with a structured instrument, addressing requisites related to universal self-care, development and health alterations. Self-care deficits corresponded to nineteen nursing diagnoses, named according to NANDA's Taxonomy II, ten of which were based on the requisites for universal self-care, five on the requisites for self-care related to development and four on the requisites for self-care related to health deviations. In care planning, goals were established and the system and health methods were selected, prioritizing support-education actions in order to engage HIV/aids patients in self-care.
Measurement of the 20F half-life
NASA Astrophysics Data System (ADS)
Hughes, M.; George, E. A.; Naviliat-Cuncic, O.; Voytas, P. A.; Chandavar, S.; Gade, A.; Huyan, X.; Liddick, S. N.; Minamisono, K.; Paulauskas, S. V.; Weisshaar, D.
2018-05-01
The half-life of the 20F ground state was measured using a radioactive beam implanted in a plastic scintillator and recording β γ coincidences together with four CsI(Na) detectors. The result, T1 /2=11.0011 (69) stat(30) sys s, is at variance by 17 combined standard deviations with the two most precise results. The present value revives the poor consistency of results for this half-life and calls for a new measurement, with a technique having different sources of systematic effects, to clarify the discrepancy.
Design of an optical PPM communication link in the presence of component tolerances
NASA Technical Reports Server (NTRS)
Chen, C.-C.
1988-01-01
A systematic approach is described for estimating the performance of an optical direct detection pulse position modulation (PPM) communication link in the presence of parameter tolerances. This approach was incorporated into the JPL optical link analysis program to provide a useful tool for optical link design. Given a set of system parameters and their tolerance specifications, the program will calculate the nominal performance margin and its standard deviation. Through use of these values, the optical link can be designed to perform adequately even under adverse operating conditions.
Terrace-like morphology of the boundary created through basal-prismatic transformation in magnesium
Liu, Bo -Yu; Wan, Liang; Wang, Jian; ...
2015-01-24
Here, the boundaries created through basal-prismatic transformation in submicron-sized single crystal magnesium have been investigated systematically using in situ transmission electron microscopy. We found that these boundaries not only deviated significantly from the twin plane associated with {101¯2} twin, but also possessed a non-planar morphology. After the sample was thinned to be less than 90 nm, aberration-corrected scanning transmission electron microscopy observation found that the basic components of these boundaries are actually terrace-like basal-prismatic interfaces.
Improved entrance optic for global irradiance measurements with a Brewer spectrophotometer.
Gröbner, Julian
2003-06-20
A new entrance optic for a Brewer spectrophotometer has been designed and tested both in the laboratory and during solar measurements. The integrated cosine response deviates by 2.4% from the ideal, with an uncertainty of +/- 1%. The systematic uncertainties of global solar irradiance measurements with this new entrance optic are considerably reduced compared with measurements with the traditional design. Simultaneous solar irradiance measurements between the Brewer spectrophotometer and a spectroradiometer equipped with a state-of-the-art shaped diffuser agreed to within +/- 2% during a five-day measurement period.
1987-09-25
rate constants, k2r using cyclic voltametry . The res tss are expressed in terms of systematic deviations oP sapparent measured" rate constants, k~b(app...concentration was taken to be lum unless otherwise noted. The voltammetric sweep rate was set at 20 V sŕ unless specified otherwise. The general procedure...peaks for the negative- and positive-going potential sweeps have opposite signs, the measured cathodic-anodic peak separation, AEp, will clearly be
Chen, Chieh-Li; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A; Kagemann, Larry; Schuman, Joel S
2016-01-01
Developing a novel image enhancement method so that nonframe-averaged optical coherence tomography (OCT) images become comparable to active eye-tracking frame-averaged OCT images. Twenty-one eyes of 21 healthy volunteers were scanned with noneye-tracking nonframe-averaged OCT device and active eye-tracking frame-averaged OCT device. Virtual averaging was applied to nonframe-averaged images with voxel resampling and adding amplitude deviation with 15-time repetitions. Signal-to-noise (SNR), contrast-to-noise ratios (CNR), and the distance between the end of visible nasal retinal nerve fiber layer (RNFL) and the foveola were assessed to evaluate the image enhancement effect and retinal layer visibility. Retinal thicknesses before and after processing were also measured. All virtual-averaged nonframe-averaged images showed notable improvement and clear resemblance to active eye-tracking frame-averaged images. Signal-to-noise and CNR were significantly improved (SNR: 30.5 vs. 47.6 dB, CNR: 4.4 vs. 6.4 dB, original versus processed, P < 0.0001, paired t -test). The distance between the end of visible nasal RNFL and the foveola was significantly different before (681.4 vs. 446.5 μm, Cirrus versus Spectralis, P < 0.0001) but not after processing (442.9 vs. 446.5 μm, P = 0.76). Sectoral macular total retinal and circumpapillary RNFL thicknesses showed systematic differences between Cirrus and Spectralis that became not significant after processing. The virtual averaging method successfully improved nontracking nonframe-averaged OCT image quality and made the images comparable to active eye-tracking frame-averaged OCT images. Virtual averaging may enable detailed retinal structure studies on images acquired using a mixture of nonframe-averaged and frame-averaged OCT devices without concerning about systematic differences in both qualitative and quantitative aspects.
[Drug assessment: IQWiG, G-BA, and an international comparison].
Glaeske, G
2016-01-01
Since the Pharmaceutical Market Restructuring Act (Arzneimittelmarktneuordnungsgesetz-AMNOG) went into effect on 1 January 2011, new medicinal products provided under statutory health insurance have to undergo an early benefit assessment, prepared on the basis of scientific dossiers drawn up by the German Institute for Quality and Cost Effectiveness in the Health Care Sector (Institut für Qualität und Wirtschaftlichkeit im Gesundheitswesen-IQWiG) and adopted by the Federal Joint Committee (Gemeinsamer Bundesausschuss-G-BA). These assessments, in which the additional benefit of a product is compared with existing standard therapy and ultimately has a bearing on price negotiations with the pharmaceutical companies, are carried out on the basis of clinical trial data presented by the latter. Results so far, however, show that the IQWIG's and the G-BA's assessments often vary, although both bodies have the same documentation. Such differences can also be observed on an international level. Using selected examples, the differences in the assessments of new pharmaceuticals are presented and reasons for national and international deviations are discussed. As yet, no systematic comparative analysis has been made of assessments of medicinal products by the respective institutions. For this reason, it was not possible to make a systematic selection of pharmaceuticals, and the cases were instead selected according to available information. An overview of the results shows that the diverging assessments-both national and international-are not always scientifically justifiable, but rather appear to be influenced by the-not always transparent-framework parameters of the respective health system. Assessments are always shaped by certain perspectives on the data and results under scrutiny. It would undoubtedly be worthwhile to evaluate these influences to gain a better understanding of the reasons for national and international discrepancies in the assessment of additional therapeutic value of new pharmaceutical products.
A systematic comparison of recurrent event models for application to composite endpoints.
Ozga, Ann-Kathrin; Kieser, Meinhard; Rauch, Geraldine
2018-01-04
Many clinical trials focus on the comparison of the treatment effect between two or more groups concerning a rarely occurring event. In this situation, showing a relevant effect with an acceptable power requires the observation of a large number of patients over a long period of time. For feasibility issues, it is therefore often considered to include several event types of interest, non-fatal or fatal, and to combine them within a composite endpoint. Commonly, a composite endpoint is analyzed with standard survival analysis techniques by assessing the time to the first occurring event. This approach neglects that an individual may experience more than one event which leads to a loss of information. As an alternative, composite endpoints could be analyzed by models for recurrent events. There exists a number of such models, e.g. regression models based on count data or Cox-based models such as the approaches of Andersen and Gill, Prentice, Williams and Peterson or, Wei, Lin and Weissfeld. Although some of the methods were already compared within the literature there exists no systematic investigation for the special requirements regarding composite endpoints. Within this work a simulation-based comparison of recurrent event models applied to composite endpoints is provided for different realistic clinical trial scenarios. We demonstrate that the Andersen-Gill model and the Prentice- Williams-Petersen models show similar results under various data scenarios whereas the Wei-Lin-Weissfeld model delivers effect estimators which can considerably deviate under commonly met data scenarios. Based on the conducted simulation study, this paper helps to understand the pros and cons of the investigated methods in the context of composite endpoints and provides therefore recommendations for an adequate statistical analysis strategy and a meaningful interpretation of results.
Chen, Chieh-Li; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A.; Kagemann, Larry; Schuman, Joel S.
2016-01-01
Purpose Developing a novel image enhancement method so that nonframe-averaged optical coherence tomography (OCT) images become comparable to active eye-tracking frame-averaged OCT images. Methods Twenty-one eyes of 21 healthy volunteers were scanned with noneye-tracking nonframe-averaged OCT device and active eye-tracking frame-averaged OCT device. Virtual averaging was applied to nonframe-averaged images with voxel resampling and adding amplitude deviation with 15-time repetitions. Signal-to-noise (SNR), contrast-to-noise ratios (CNR), and the distance between the end of visible nasal retinal nerve fiber layer (RNFL) and the foveola were assessed to evaluate the image enhancement effect and retinal layer visibility. Retinal thicknesses before and after processing were also measured. Results All virtual-averaged nonframe-averaged images showed notable improvement and clear resemblance to active eye-tracking frame-averaged images. Signal-to-noise and CNR were significantly improved (SNR: 30.5 vs. 47.6 dB, CNR: 4.4 vs. 6.4 dB, original versus processed, P < 0.0001, paired t-test). The distance between the end of visible nasal RNFL and the foveola was significantly different before (681.4 vs. 446.5 μm, Cirrus versus Spectralis, P < 0.0001) but not after processing (442.9 vs. 446.5 μm, P = 0.76). Sectoral macular total retinal and circumpapillary RNFL thicknesses showed systematic differences between Cirrus and Spectralis that became not significant after processing. Conclusion The virtual averaging method successfully improved nontracking nonframe-averaged OCT image quality and made the images comparable to active eye-tracking frame-averaged OCT images. Translational Relevance Virtual averaging may enable detailed retinal structure studies on images acquired using a mixture of nonframe-averaged and frame-averaged OCT devices without concerning about systematic differences in both qualitative and quantitative aspects. PMID:26835180
Analysis of using the tongue deviation angle as a warning sign of a stroke
2012-01-01
Background The symptom of tongue deviation is observed in a stroke or transient ischemic attack. Nevertheless, there is much room for the interpretation of the tongue deviation test. The crucial factor is the lack of an effective quantification method of tongue deviation. If we can quantify the features of the tongue deviation and scientifically verify the relationship between the deviation angle and a stroke, the information provided by the tongue will be helpful in recognizing a warning of a stroke. Methods In this study, a quantification method of the tongue deviation angle was proposed for the first time to characterize stroke patients. We captured the tongue images of stroke patients (15 males and 10 females, ranging between 55 and 82 years of age); transient ischemic attack (TIA) patients (16 males and 9 females, ranging between 53 and 79 years of age); and normal subjects (14 males and 11 females, ranging between 52 and 80 years of age) to analyze whether the method is effective. In addition, we used the receiver operating characteristic curve (ROC) for the sensitivity analysis, and determined the threshold value of the tongue deviation angle for the warning sign of a stroke. Results The means and standard deviations of the tongue deviation angles of the stroke, TIA, and normal groups were: 6.9 ± 3.1, 4.9 ± 2.1 and 1.4 ± 0.8 degrees, respectively. Analyzed by the unpaired Student’s t-test, the p-value between the stroke group and the TIA group was 0.015 (>0.01), indicating no significant difference in the tongue deviation angle. The p-values between the stroke group and the normal group, as well as between the TIA group and the normal group were both less than 0.01. These results show the significant differences in the tongue deviation angle between the patient groups (stroke and TIA patients) and the normal group. These results also imply that the tongue deviation angle can effectively identify the patient group (stroke and TIA patients) and the normal group. With respect to the visual examination, 40% and 32% of stroke patients, 24% and 16% of TIA patients, and 4% and 0% of normal subjects were found to have tongue deviations when physicians “A” and “B” examined them. The variation showed the essentiality of the quantification method in a clinical setting. In the receiver operating characteristic curve (ROC), the Area Under Curve (AUC, = 0.96) indicates good discrimination. The tongue deviation angle more than the optimum threshold value (= 3.2°) predicts a risk of stroke. Conclusions In summary, we developed an effective quantification method to characterize the tongue deviation angle, and we confirmed the feasibility of recognizing the tongue deviation angle as an early warning sign of an impending stroke. PMID:22908956
Analysis of using the tongue deviation angle as a warning sign of a stroke.
Wei, Ching-Chuan; Huang, Shu-Wen; Hsu, Sheng-Lin; Chen, Hsing-Chung; Chen, Jong-Shin; Liang, Hsinying
2012-08-21
The symptom of tongue deviation is observed in a stroke or transient ischemic attack. Nevertheless, there is much room for the interpretation of the tongue deviation test. The crucial factor is the lack of an effective quantification method of tongue deviation. If we can quantify the features of the tongue deviation and scientifically verify the relationship between the deviation angle and a stroke, the information provided by the tongue will be helpful in recognizing a warning of a stroke. In this study, a quantification method of the tongue deviation angle was proposed for the first time to characterize stroke patients. We captured the tongue images of stroke patients (15 males and 10 females, ranging between 55 and 82 years of age); transient ischemic attack (TIA) patients (16 males and 9 females, ranging between 53 and 79 years of age); and normal subjects (14 males and 11 females, ranging between 52 and 80 years of age) to analyze whether the method is effective. In addition, we used the receiver operating characteristic curve (ROC) for the sensitivity analysis, and determined the threshold value of the tongue deviation angle for the warning sign of a stroke. The means and standard deviations of the tongue deviation angles of the stroke, TIA, and normal groups were: 6.9 ± 3.1, 4.9 ± 2.1 and 1.4 ± 0.8 degrees, respectively. Analyzed by the unpaired Student's t-test, the p-value between the stroke group and the TIA group was 0.015 (>0.01), indicating no significant difference in the tongue deviation angle. The p-values between the stroke group and the normal group, as well as between the TIA group and the normal group were both less than 0.01. These results show the significant differences in the tongue deviation angle between the patient groups (stroke and TIA patients) and the normal group. These results also imply that the tongue deviation angle can effectively identify the patient group (stroke and TIA patients) and the normal group. With respect to the visual examination, 40% and 32% of stroke patients, 24% and 16% of TIA patients, and 4% and 0% of normal subjects were found to have tongue deviations when physicians "A" and "B" examined them. The variation showed the essentiality of the quantification method in a clinical setting. In the receiver operating characteristic curve (ROC), the Area Under Curve (AUC, = 0.96) indicates good discrimination. The tongue deviation angle more than the optimum threshold value (= 3.2°) predicts a risk of stroke. In summary, we developed an effective quantification method to characterize the tongue deviation angle, and we confirmed the feasibility of recognizing the tongue deviation angle as an early warning sign of an impending stroke.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bai, Sen; Li, Guangjun; Wang, Maojie
The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors weremore » 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.« less
Are Study and Journal Characteristics Reliable Indicators of "Truth" in Imaging Research?
Frank, Robert A; McInnes, Matthew D F; Levine, Deborah; Kressel, Herbert Y; Jesurum, Julia S; Petrcich, William; McGrath, Trevor A; Bossuyt, Patrick M
2018-04-01
Purpose To evaluate whether journal-level variables (impact factor, cited half-life, and Standards for Reporting of Diagnostic Accuracy Studies [STARD] endorsement) and study-level variables (citation rate, timing of publication, and order of publication) are associated with the distance between primary study results and summary estimates from meta-analyses. Materials and Methods MEDLINE was searched for meta-analyses of imaging diagnostic accuracy studies, published from January 2005 to April 2016. Data on journal-level and primary-study variables were extracted for each meta-analysis. Primary studies were dichotomized by variable as first versus subsequent publication, publication before versus after STARD introduction, STARD endorsement, or by median split. The mean absolute deviation of primary study estimates from the corresponding summary estimates for sensitivity and specificity was compared between groups. Means and confidence intervals were obtained by using bootstrap resampling; P values were calculated by using a t test. Results Ninety-eight meta-analyses summarizing 1458 primary studies met the inclusion criteria. There was substantial variability, but no significant differences, in deviations from the summary estimate between paired groups (P > .0041 in all comparisons). The largest difference found was in mean deviation for sensitivity, which was observed for publication timing, where studies published first on a topic demonstrated a mean deviation that was 2.5 percentage points smaller than subsequently published studies (P = .005). For journal-level factors, the greatest difference found (1.8 percentage points; P = .088) was in mean deviation for sensitivity in journals with impact factors above the median compared with those below the median. Conclusion Journal- and study-level variables considered important when evaluating diagnostic accuracy information to guide clinical decisions are not systematically associated with distance from the truth; critical appraisal of individual articles is recommended. © RSNA, 2017 Online supplemental material is available for this article.
Accounting for body size deviations when reporting bone mineral density variables in children.
Webber, C E; Sala, A; Barr, R D
2009-01-01
In a child, bone mineral density (BMD) may differ from an age-expected normal value, not only because of the presence of disease, but also because of deviations of height or weight from population averages. Appropriate adjustment for body size deviations simplifies interpretation of BMD measurements. For children, a bone mineral density (BMD) measurement is normally expressed as a Z score. Interpretation is complicated when weight or height distinctly differ from age-matched children. We develop a procedure to allow for the influence of body size deviations upon measured BMD. We examined the relation between body size deviation and spine, hip and whole body BMD deviation in 179 normal children (91 girls). Expressions were developed that allowed derivation of an expected BMD based on age, gender and body size deviation. The difference between measured and expected BMD was expressed as a HAW score (Height-, Age-, Weight-adjusted score). In a second independent sample of 26 normal children (14 girls), measured spine, total femur and whole body BMD all fell within the same single normal range after accounting for age, gender and body size deviations. When traditional Z scores and HAW scores were compared in 154 children, 17.5% showed differences of more than 1 unit and such differences were associated with height and weight deviations. For almost 1 in 5 children, body size deviations influence BMD to an extent that could alter clinical management.
NASA Astrophysics Data System (ADS)
Chetvertkov, Mikhail A.
Purpose: To develop standard and regularized principal component analysis (PCA) models of anatomical changes from daily cone beam CTs (CBCTs) of head and neck (H&N) patients, assess their potential use in adaptive radiation therapy (ART), and to extract quantitative information for treatment response assessment. Methods: Planning CT (pCT) images of H&N patients were artificially deformed to create "digital phantom" images, which modeled systematic anatomical changes during Radiation Therapy (RT). Artificial deformations closely mirrored patients' actual deformations, and were interpolated to generate 35 synthetic CBCTs, representing evolving anatomy over 35 fractions. Deformation vector fields (DVFs) were acquired between pCT and synthetic CBCTs (i.e., digital phantoms), and between pCT and clinical CBCTs. Patient-specific standard PCA (SPCA) and regularized PCA (RPCA) models were built from these synthetic and clinical DVF sets. Eigenvectors, or eigenDVFs (EDVFs), having the largest eigenvalues were hypothesized to capture the major anatomical deformations during treatment. Modeled anatomies were used to assess the dose deviations with respect to the planned dose distribution. Results: PCA models achieve variable results, depending on the size and location of anatomical change. Random changes prevent or degrade SPCA's ability to detect underlying systematic change. RPCA is able to detect smaller systematic changes against the background of random fraction-to-fraction changes, and is therefore more successful than SPCA at capturing systematic changes early in treatment. SPCA models were less successful at modeling systematic changes in clinical patient images, which contain a wider range of random motion than synthetic CBCTs, while the regularized approach was able to extract major modes of motion. For dose assessment it has been shown that the modeled dose distribution was different from the planned dose for the parotid glands due to their shrinkage and shift into the higher dose volumes during the radiotherapy course. Modeled DVHs still underestimated the effect of parotid shrinkage due to the large compression factor (CF) used to acquire DVFs. Conclusion: Leading EDVFs from both PCA approaches have the potential to capture systematic anatomical changes during H&N radiotherapy when systematic changes are large enough with respect to random fraction-to-fraction changes. In all cases the RPCA approach appears to be more reliable than SPCA at capturing systematic changes, enabling dosimetric consequences to be projected to the future treatment fractions based on trends established early in a treatment course, or, potentially, based on population models. This work showed that PCA has a potential in identifying the major mode of anatomical changes during the radiotherapy course and subsequent use of this information in future dose predictions is feasible. Use of smaller CF values for DVFs is preferred, otherwise anatomical motion will be underestimated.
Alagar, Ananda Giri Babu; Mani, Ganesh Kadirampatti; Karunakaran, Kaviarasu
2016-01-08
Small fields smaller than 4 × 4 cm2 are used in stereotactic and conformal treatments where heterogeneity is normally present. Since dose calculation accuracy in both small fields and heterogeneity often involves more discrepancy, algorithms used by treatment planning systems (TPS) should be evaluated for achieving better treatment results. This report aims at evaluating accuracy of four model-based algorithms, X-ray Voxel Monte Carlo (XVMC) from Monaco, Superposition (SP) from CMS-Xio, AcurosXB (AXB) and analytical anisotropic algorithm (AAA) from Eclipse are tested against the measurement. Measurements are done using Exradin W1 plastic scintillator in Solid Water phantom with heterogeneities like air, lung, bone, and aluminum, irradiated with 6 and 15 MV photons of square field size ranging from 1 to 4 cm2. Each heterogeneity is introduced individually at two different depths from depth-of-dose maximum (Dmax), one setup being nearer and another farther from the Dmax. The central axis percentage depth-dose (CADD) curve for each setup is measured separately and compared with the TPS algorithm calculated for the same setup. The percentage normalized root mean squared deviation (%NRMSD) is calculated, which represents the whole CADD curve's deviation against the measured. It is found that for air and lung heterogeneity, for both 6 and 15 MV, all algorithms show maximum deviation for field size 1 × 1 cm2 and gradually reduce when field size increases, except for AAA. For aluminum and bone, all algorithms' deviations are less for 15 MV irrespective of setup. In all heterogeneity setups, 1 × 1 cm2 field showed maximum deviation, except in 6MV bone setup. All algorithms in the study, irrespective of energy and field size, when any heterogeneity is nearer to Dmax, the dose deviation is higher compared to the same heterogeneity far from the Dmax. Also, all algorithms show maximum deviation in lower-density materials compared to high-density materials.
2015-01-01
The 0–0 energies of 80 medium and large molecules have been computed with a large panel of theoretical formalisms. We have used an approach computationally tractable for large molecules, that is, the structural and vibrational parameters are obtained with TD-DFT, the solvent effects are accounted for with the PCM model, whereas the total and transition energies have been determined with TD-DFT and with five wave function approaches accounting for contributions from double excitations, namely, CIS(D), ADC(2), CC2, SCS-CC2, and SOS-CC2, as well as Green’s function based BSE/GW approach. Atomic basis sets including diffuse functions have been systematically applied, and several variations of the PCM have been evaluated. Using solvent corrections obtained with corrected linear-response approach, we found that three schemes, namely, ADC(2), CC2, and BSE/GW allow one to reach a mean absolute deviation smaller than 0.15 eV compared to the measurements, the two former yielding slightly better correlation with experiments than the latter. CIS(D), SCS-CC2, and SOS-CC2 provide significantly larger deviations, though the latter approach delivers highly consistent transition energies. In addition, we show that (i) ADC(2) and CC2 values are extremely close to each other but for systems absorbing at low energies; (ii) the linear-response PCM scheme tends to overestimate solvation effects; and that (iii) the average impact of nonequilibrium correction on 0–0 energies is negligible. PMID:26574326
NASA Astrophysics Data System (ADS)
Kuderer, Matthias; Hammer, Samuel; Levin, Ingeborg
2018-06-01
Atmospheric Δ14CO2 measurements are a well-established tool to estimate the regional fossil-fuel-derived CO2 component. However, emissions from nuclear facilities can significantly alter the regional Δ14CO2 level. In order to accurately quantify the signal originating from fossil CO2 emissions, a correction term for anthropogenic 14CO2 sources has to be determined. In this study, the HYSPLIT atmospheric dispersion model has been applied to calculate this correction for the long-term Δ14CO2 monitoring site in Heidelberg. Wind fields with a spatial resolution of 2.5° × 2.5°, 1° × 1°, and 0.5° × 0.5° show systematic deviations, with coarser resolved wind fields leading to higher mean values for the correction. The finally applied mean Δ14CO2 correction for the period from 1986-2014 is 2.3 ‰ with a standard deviation of 2.1 ‰ and maximum values up to 15.2 ‰. These results are based on the 0.5° × 0.5° wind field simulations in years when these fields were available (2009, 2011-2014), and for the other years they are based on 2.5° × 2.5° wind field simulations, corrected with a factor of 0.43. After operations at the Philippsburg boiling water reactor ceased in 2011, the monthly nuclear correction terms decreased to less than 2 ‰, with a mean value of 0.44 ± 0.32 ‰ from 2012 to 2014.
Cheng, Lan; Gauss, Jürgen; Ruscic, Branko; ...
2017-01-12
Benchmark scalar-relativistic coupled-cluster calculations for dissociation energies of the 20 diatomic molecules containing 3d transition metals in the 3dMLBE20 database ( J. Chem. Theory Comput. 2015, 11, 2036) are reported in this paper. Electron correlation and basis set effects are systematically studied. The agreement between theory and experiment is in general satisfactory. For a subset of 16 molecules, the standard deviation between computational and experimental values is 9 kJ/mol with the maximum deviation being 15 kJ/mol. The discrepancies between theory and experiment remain substantial (more than 20 kJ/mol) for VH, CrH, CoH, and FeH. To explore the source of themore » latter discrepancies, the analysis used to determine the experimental dissociation energies for VH and CrH is revisited. It is shown that, if improved values are used for the heterolytic C–H dissociation energies of di- and trimethylamine involved in the experimental determination, the experimental values for the dissociation energies of VH and CrH are increased by 18 kJ/mol, such that D 0(VH) = 223 ± 7 kJ/mol and D 0(CrH) = 204 ± 7 kJ/mol (or D e(VH) = 233 ± 7 kJ/mol and D e(CrH) = 214 ± 7 kJ/mol). Finally, the new experimental values agree quite well with the calculated values, showing the consistency of the computation and the measured reaction thresholds.« less
Static Scene Statistical Non-Uniformity Correction
2015-03-01
Error NUC Non-Uniformity Correction RMSE Root Mean Squared Error RSD Relative Standard Deviation S3NUC Static Scene Statistical Non-Uniformity...Deviation ( RSD ) which normalizes the standard deviation, σ, to the mean estimated value, µ using the equation RS D = σ µ × 100. The RSD plot of the gain...estimates is shown in Figure 4.1(b). The RSD plot shows that after a sample size of approximately 10, the different photocount values and the inclusion
Walker, R.J.; Horan, M.F.; Morgan, J.W.; Becker, H.; Grossman, J.N.; Rubin, A.E.
2002-01-01
A suite of 47 carbonaceous, enstatite, and ordinary chondrites are examined for Re-Os isotopic systematics. There are significant differences in the 187Re/188Os and 187Os/188Os ratios of carbonaceous chondrites compared with ordinary and enstatite chondrites. The average 187Re/188Os for carbonaceous chondrites is 0.392 ?? 0.015 (excluding the CK chondrite, Karoonda), compared with 0.422 ?? 0.025 and 0.421 ?? 0.013 for ordinary and enstatite chondrites (1?? standard deviations). These ratios, recast into elemental Re/Os ratios, are as follows: 0.0814 ?? 0.0031, 0.0876 ?? 0.0052 and 0.0874 ?? 0.0027 respectively. Correspondingly, the 187Os/188Os ratios of carbonaceous chondrites average 0.1262 ?? 0.0006 (excluding Karoonda), and ordinary and enstatite chondrites average 0.1283 ?? 0.0017 and 0.1281 ?? 0.0004, respectively (1?? standard deviations). The new results indicate that the Re/Os ratios of meteorites within each group are, in general, quite uniform. The minimal overlap between the isotopic compositions of ordinary and enstatite chondrites vs. carbonaceous chondrites indicates long-term differences in Re/Os for these materials, most likely reflecting chemical fractionation early in solar system history. A majority of the chondrites do not plot within analytical uncertainties of a 4.56-Ga reference isochron. Most of the deviations from the isochron are consistent with minor, relatively recent redistribution of Re and/or Os on a scale of millimeters to centimeters. Some instances of the redistribution may be attributed to terrestrial weathering; others are most likely the result of aqueous alteration or shock events on the parent body within the past 2 Ga. The 187Os/188Os ratio of Earth's primitive upper mantle has been estimated to be 0.1296 ?? 8. If this composition was set via addition of a late veneer of planetesimals after core formation, the composition suggests the veneer was dominated by materials that had Re/Os ratios most similar to ordinary and enstatite chondrites. ?? 2002 Elsevier Science Ltd.
[ELEMENTS OF A SYSTEMATIC APPROACH TO HYGIENIC REGULATION OF XENOBIOTICS].
Shtabskiy, B M; Gzhegotskiy, M R; Shafran, L M
2016-01-01
Hygienic standardization (HS) of chemicals remains to be the one of the effective ways to ensure chemical safety of the population. At that hygienic standards (such as maximum allowable concentrations--MACs) are interrelated and aggregated into the coherent systems. Therefore, the task of the study was in establishment of the logic of inter- standard relations between the existing standards and actualization of legitimate relations of the interrelations such as MACwz/MACatm, (i.e., to systematize standards) and so as CL₅₀/MACwz (reflecting the ratio of reliability). In the suggested systemic approach the benchmark indices of the proposed HS system are the values of the MACwz. Standards for other media, including atmosphere air may be only some compartments of MACwz. The performed studies and calculations allowed to justify and implement the system approach into the practice of HS in Ukraine. There is need for further search for additional solutions in nonreachability of LC₅₀ in the experiment, justification of standards for the population in the absence of MACwz, comparison with the data of normative databases of other countries. It is necessary to introduce the value of permissible deviation from the requirements of the systemness, to embody conditions (1)-(7) into the general principle of the prohibition of greater deviation and to harmonize acting and newly introduced standards within frameworks of modern ideology and methods of HS of harmful substances. This opens up broad prospects for the new phase of HS and a significant increase in the reliability of results obtained by the various methods and in different laboratories.
Harvey, E M; Miller, J M; Dobson, V
1995-01-01
AIMS--To evaluate the overall accuracy and reproducibility of the Alcon portable autokeratometer (PAK) measurements in infants and young children. METHODS--The accuracy of the Alcon PAK in measuring toric reference surfaces (1, 3, 5, and 7 D) under various suboptimal measurement conditions was assessed, and the reproducibility of PAK measurements of corneal astigmatism in newborn infants (n = 5), children (n = 19, age 3-5 years), and adults (n = 14) was evaluated. RESULTS--Measurements of toric reference surfaces indicated (a) no significant effect of distance (17-30 mm) on accuracy of measurements, (b) no systematic relation between amount of toricity and accuracy of measurements, (c) no systematic relation between angle of measurement and accuracy, (d) no difference in accuracy of measurements when the PAK is hand held in comparison with when it is mounted, (e) no difference in accuracy of measurements when axis of toricity is oriented obliquely than when it is oriented horizontally, with respect to the PAK, and (f) a small positive bias (+0.16 D) in measurement of spherical equivalent. The PAK did not prove useful for screening newborns. However, measurements were successfully obtained from 18/19 children and 14/14 adults. There was no significant difference in median measurement deviation (deviation of a subject's five measurements from his/her mean) between children (0.21 D) and adults (0.13 D). CONCLUSIONS--The PAK produces accurate measurements of surface curvature under a variety of suboptimal conditions. Variability of PAK measurements in preschool children is small enough to suggest that it would be useful for screening for corneal astigmatism in young children. PMID:8534668
Allocentric information is used for memory-guided reaching in depth: A virtual reality study.
Klinghammer, Mathias; Schütz, Immo; Blohm, Gunnar; Fiehler, Katja
2016-12-01
Previous research has demonstrated that humans use allocentric information when reaching to remembered visual targets, but most of the studies are limited to 2D space. Here, we study allocentric coding of memorized reach targets in 3D virtual reality. In particular, we investigated the use of allocentric information for memory-guided reaching in depth and the role of binocular and monocular (object size) depth cues for coding object locations in 3D space. To this end, we presented a scene with objects on a table which were located at different distances from the observer and served as reach targets or allocentric cues. After free visual exploration of this scene and a short delay the scene reappeared, but with one object missing (=reach target). In addition, the remaining objects were shifted horizontally or in depth. When objects were shifted in depth, we also independently manipulated object size by either magnifying or reducing their size. After the scene vanished, participants reached to the remembered target location on the blank table. Reaching endpoints deviated systematically in the direction of object shifts, similar to our previous results from 2D presentations. This deviation was stronger for object shifts in depth than in the horizontal plane and independent of observer-target-distance. Reaching endpoints systematically varied with changes in object size. Our results suggest that allocentric information is used for coding targets for memory-guided reaching in depth. Thereby, retinal disparity and vergence as well as object size provide important binocular and monocular depth cues. Copyright © 2016 Elsevier Ltd. All rights reserved.
Improved ambiguity resolution for URTK with dynamic atmosphere constraints
NASA Astrophysics Data System (ADS)
Tang, Weiming; Liu, Wenjian; Zou, Xuan; Li, Zongnan; Chen, Liang; Deng, Chenlong; Shi, Chuang
2016-12-01
Raw observation processing method with prior knowledge of ionospheric delay could strengthen the ambiguity resolution (AR), but it does not make full use of the relatively longer wavelength of wide-lane (WL) observation. Furthermore, the accuracy of calculated atmospheric delays from the regional augmentation information has quite different in quality, while the atmospheric constraint used in the current methods is usually set to an empirical value. A proper constraint, which matches the accuracy of calculated atmospheric delays, can most effectively compensate the residual systematic biases caused by large inter-station distances. Therefore, the standard deviation of the residual atmospheric parameters should be fine-tuned. This paper presents an atmosphere-constrained AR method for undifferenced network RTK (URTK) rover, whose ambiguities are sequentially fixed according to their wavelengths. Furthermore, this research systematically analyzes the residual atmospheric error and finds that it mainly varies along the positional relationship between the rover and the chosen reference stations. More importantly, its ionospheric part of certain location will also be cyclically influenced every day. Therefore, the standard deviation of residual ionospheric error can be modeled by a daily repeated cosine or other functions with the help of data one day before, and applied by rovers as pseudo-observation. With the data collected at 29 stations from a continuously operating reference station network in Guangdong Province (GDCORS) in China, the efficiency of the proposed approach is confirmed by improving the success and error rates of AR for 10-20 % compared to that of the WL-L1-IF one, as well as making much better positioning accuracy.
A microwave satellite water vapour column retrieval for polar winter conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perro, Christopher; Lesins, Glen; Duck, Thomas J.
A new microwave satellite water vapour retrieval for the polar winter atmosphere is presented. The retrieval builds on the work of Miao et al. (2001) and Melsheimer and Heygster (2008), employing auxiliary information for atmospheric conditions and numerical optimization. It was tested using simulated and actual measurements from the Microwave Humidity Sounder (MHS) satellite instruments. Ground truth was provided by the G-band vapour radiometer (GVR) at Barrow, Alaska. For water vapour columns less than 6 kg m -2, comparisons between the retrieval and GVR result in a root mean square (RMS) deviation of 0.39 kg m -2 and a systematic bias of 0.08 kg m -2. These results aremore » compared with RMS deviations and biases at Barrow for the retrieval of Melsheimer and Heygster (2008), the AIRS and MIRS satellite data products, and the ERA-Interim, NCEP, JRA-55, and ASR reanalyses. When applied to MHS measurements, the new retrieval produces a smaller RMS deviation and bias than for the earlier retrieval and satellite data products. The RMS deviations for the new retrieval were comparable to those for the ERA-Interim, JRA-55, and ASR reanalyses; however, the MHS retrievals have much finer horizontal resolution (15 km at nadir) and reveal more structure. The new retrieval can be used to obtain pan-Arctic maps of water vapour columns of unprecedented quality. It may also be applied to measurements from the Special Sensor Microwave/Temperature 2 (SSM/T2), Advanced Microwave Sounding Unit B (AMSU-B), Special Sensor Microwave Imager/Sounder (SSMIS), Advanced Technology Microwave Sounder (ATMS), and Chinese MicroWave Humidity Sounder (MWHS) instruments.« less
Hendriks, A Jan; Awkerman, Jill A; de Zwart, Dick; Huijbregts, Mark A J
2013-11-01
While variable sensitivity of model species to common toxicants has been addressed in previous studies, a systematic analysis of inter-species variability for different test types, modes of action and species is as of yet lacking. Hence, the aim of the present study was to identify similarities and differences in contaminant levels affecting cold-blooded and warm-blooded species administered via different routes. To that end, data on lethal water concentrations LC50, tissue residues LR50 and oral doses LD50 were collected from databases, each representing the largest of its kind. LC50 data were multiplied by a bioconcentration factor (BCF) to convert them to internal concentrations that allow for comparison among species. For each endpoint data set, we calculated the mean and standard deviation of species' lethal level per compound. Next, the means and standard deviations were averaged by mode of action. Both the means and standard deviations calculated depended on the number of species tested, which is at odds with quality standard setting procedures. Means calculated from (BCF) LC50, LR50 and LD50 were largely similar, suggesting that different administration routes roughly yield similar internal levels. Levels for compounds interfering biochemically with elementary life processes were about one order of magnitude below that of narcotics disturbing membranes, and neurotoxic pesticides and dioxins induced death in even lower amounts. Standard deviations for LD50 data were similar across modes of action, while variability of LC50 values was lower for narcotics than for substances with a specific mode of action. The study indicates several directions to go for efficient use of available data in risk assessment and reduction of species testing. Copyright © 2013 Elsevier Inc. All rights reserved.
Galaxy–galaxy lensing estimators and their covariance properties
Singh, Sukhdeep; Mandelbaum, Rachel; Seljak, Uros; ...
2017-07-21
Here, we study the covariance properties of real space correlation function estimators – primarily galaxy–shear correlations, or galaxy–galaxy lensing – using SDSS data for both shear catalogues and lenses (specifically the BOSS LOWZ sample). Using mock catalogues of lenses and sources, we disentangle the various contributions to the covariance matrix and compare them with a simple analytical model. We show that not subtracting the lensing measurement around random points from the measurement around the lens sample is equivalent to performing the measurement using the lens density field instead of the lens overdensity field. While the measurement using the lens densitymore » field is unbiased (in the absence of systematics), its error is significantly larger due to an additional term in the covariance. Therefore, this subtraction should be performed regardless of its beneficial effects on systematics. Comparing the error estimates from data and mocks for estimators that involve the overdensity, we find that the errors are dominated by the shape noise and lens clustering, which empirically estimated covariances (jackknife and standard deviation across mocks) that are consistent with theoretical estimates, and that both the connected parts of the four-point function and the supersample covariance can be neglected for the current levels of noise. While the trade-off between different terms in the covariance depends on the survey configuration (area, source number density), the diagnostics that we use in this work should be useful for future works to test their empirically determined covariances.« less
Automated Detection of Knickpoints and Knickzones Across Transient Landscapes
NASA Astrophysics Data System (ADS)
Gailleton, B.; Mudd, S. M.; Clubb, F. J.
2017-12-01
Mountainous regions are ubiquitously dissected by river channels, which transmit climate and tectonic signals to the rest of the landscape by adjusting their long profiles. Fluvial response to allogenic forcing is often expressed through the upstream propagation of steepened reaches, referred to as knickpoints or knickzones. The identification and analysis of these steepened reaches has numerous applications in geomorphology, such as modelling long-term landscape evolution, understanding controls on fluvial incision, and constraining tectonic uplift histories. Traditionally, the identification of knickpoints or knickzones from fluvial profiles requires manual selection or calibration. This process is both time-consuming and subjective, as different workers may select different steepened reaches within the profile. We propose an objective, statistically-based method to systematically pick knickpoints/knickzones on a landscape scale using an outlier-detection algorithm. Our method integrates river profiles normalised by drainage area (Chi, using the approach of Perron and Royden, 2013), then separates the chi-elevation plots into a series of transient segments using the method of Mudd et al. (2014). This method allows the systematic detection of knickpoints across a DEM, regardless of size, using a high-performance algorithm implemented in the open-source Edinburgh Land Surface Dynamics Topographic Tools (LSDTopoTools) software package. After initial knickpoint identification, outliers are selected using several sorting and binning methods based on the Median Absolute Deviation, to avoid the influence sample size. We test our method on a series of DEMs and grid resolutions, and show that our method consistently identifies accurate knickpoint locations across each landscape tested.
NASA Astrophysics Data System (ADS)
Holloway, Christopher L.; Simons, Matt T.; Gordon, Joshua A.; Dienstfrey, Andrew; Anderson, David A.; Raithel, Georg
2017-06-01
We investigate the relationship between the Rabi frequency (ΩRF, related to the applied electric field) and Autler-Townes (AT) splitting, when performing atom-based radio-frequency (RF) electric (E) field strength measurements using Rydberg states and electromagnetically induced transparency (EIT) in an atomic vapor. The AT splitting satisfies, under certain conditions, a well-defined linear relationship with the applied RF field amplitude. The EIT/AT-based E-field measurement approach derived from these principles is currently being investigated by several groups around the world as a means to develop a new SI-traceable RF E-field measurement technique. We establish conditions under which the measured AT-splitting is an approximately linear function of the RF electric field. A quantitative description of systematic deviations from the linear relationship is key to exploiting EIT/AT-based atomic-vapor spectroscopy for SI-traceable field measurement. We show that the linear relationship is valid and can be used to determine the E-field strength, with minimal error, as long as the EIT linewidth is small compared to the AT-splitting. We also discuss interesting aspects of the thermal dependence (i.e., hot- versus cold-atom) of this EIT-AT technique. An analysis of the transition from cold- to hot-atom EIT in a Doppler-mismatched cascade system reveals a significant change of the dependence of the EIT linewidth on the optical Rabi frequencies and of the AT-splitting on ΩRF.
Galaxy–galaxy lensing estimators and their covariance properties
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, Sukhdeep; Mandelbaum, Rachel; Seljak, Uros
Here, we study the covariance properties of real space correlation function estimators – primarily galaxy–shear correlations, or galaxy–galaxy lensing – using SDSS data for both shear catalogues and lenses (specifically the BOSS LOWZ sample). Using mock catalogues of lenses and sources, we disentangle the various contributions to the covariance matrix and compare them with a simple analytical model. We show that not subtracting the lensing measurement around random points from the measurement around the lens sample is equivalent to performing the measurement using the lens density field instead of the lens overdensity field. While the measurement using the lens densitymore » field is unbiased (in the absence of systematics), its error is significantly larger due to an additional term in the covariance. Therefore, this subtraction should be performed regardless of its beneficial effects on systematics. Comparing the error estimates from data and mocks for estimators that involve the overdensity, we find that the errors are dominated by the shape noise and lens clustering, which empirically estimated covariances (jackknife and standard deviation across mocks) that are consistent with theoretical estimates, and that both the connected parts of the four-point function and the supersample covariance can be neglected for the current levels of noise. While the trade-off between different terms in the covariance depends on the survey configuration (area, source number density), the diagnostics that we use in this work should be useful for future works to test their empirically determined covariances.« less
Galaxy-galaxy lensing estimators and their covariance properties
NASA Astrophysics Data System (ADS)
Singh, Sukhdeep; Mandelbaum, Rachel; Seljak, Uroš; Slosar, Anže; Vazquez Gonzalez, Jose
2017-11-01
We study the covariance properties of real space correlation function estimators - primarily galaxy-shear correlations, or galaxy-galaxy lensing - using SDSS data for both shear catalogues and lenses (specifically the BOSS LOWZ sample). Using mock catalogues of lenses and sources, we disentangle the various contributions to the covariance matrix and compare them with a simple analytical model. We show that not subtracting the lensing measurement around random points from the measurement around the lens sample is equivalent to performing the measurement using the lens density field instead of the lens overdensity field. While the measurement using the lens density field is unbiased (in the absence of systematics), its error is significantly larger due to an additional term in the covariance. Therefore, this subtraction should be performed regardless of its beneficial effects on systematics. Comparing the error estimates from data and mocks for estimators that involve the overdensity, we find that the errors are dominated by the shape noise and lens clustering, which empirically estimated covariances (jackknife and standard deviation across mocks) that are consistent with theoretical estimates, and that both the connected parts of the four-point function and the supersample covariance can be neglected for the current levels of noise. While the trade-off between different terms in the covariance depends on the survey configuration (area, source number density), the diagnostics that we use in this work should be useful for future works to test their empirically determined covariances.
Fesharaki, Maryam; Karagiannis, Peter; Tweed, Douglas; Sharpe, James A.; Wong, Agnes M. F.
2016-01-01
Purpose Skew deviation is a vertical strabismus caused by damage to the otolithic–ocular reflex pathway and is associated with abnormal ocular torsion. This study was conducted to determine whether patients with skew deviation show the normal pattern of three-dimensional eye control called Listing’s law, which specifies the eye’s torsional angle as a function of its horizontal and vertical position. Methods Ten patients with skew deviation caused by brain stem or cerebellar lesions and nine normal control subjects were studied. Patients with diplopia and neurologic symptoms less than 1 month in duration were designated as acute (n = 4) and those with longer duration were classified as chronic (n = 10). Serial recordings were made in the four patients with acute skew deviation. With the head immobile, subjects made saccades to a target that moved between straight ahead and eight eccentric positions, while wearing search coils. At each target position, fixation was maintained for 3 seconds before the next saccade. From the eye position data, the plane of best fit, referred to as Listing’s plane, was fitted. Violations of Listing’s law were quantified by computing the “thickness” of this plane, defined as the SD of the distances to the plane from the data points. Results Both the hypertropic and hypotropic eyes in patients with acute skew deviation violated Listing’s and Donders’ laws—that is, the eyes did not show one consistent angle of torsion in any given gaze direction, but rather an abnormally wide range of torsional angles. In contrast, each eye in patients with chronic skew deviation obeyed the laws. However, in chronic skew deviation, Listing’s planes in both eyes had abnormal orientations. Conclusions Patients with acute skew deviation violated Listing’s law, whereas those with chronic skew deviation obeyed it, indicating that despite brain lesions, neural adaptation can restore Listing’s law so that the neural linkage between horizontal, vertical, and torsional eye position remains intact. Violation of Listing’s and Donders’ laws during fixation arises primarily from torsional drifts, indicating that patients with acute skew deviation have unstable torsional gaze holding that is independent of their horizontal–vertical eye positions. PMID:18172094
Parabolic trough receiver heat loss and optical efficiency round robin 2015/2016
NASA Astrophysics Data System (ADS)
Pernpeintner, Johannes; Schiricke, Björn; Sallaberry, Fabienne; de Jalón, Alberto García; López-Martín, Rafael; Valenzuela, Loreto; de Luca, Antonio; Georg, Andreas
2017-06-01
A round robin for parabolic trough receiver heat loss and optical efficiency in the laboratory was performed between five institutions using five receivers in 2015/2016. Heat loss testing was performed at three cartridge heater test benches and one Joule heating test bench in the temperature range between 100 °C and 550 °C. Optical efficiency testing was performed with two spectrometric test bench and one calorimetric test bench. Heat loss testing results showed standard deviations at the order of 6% to 12 % for most temperatures and receivers and a standard deviation of 17 % for one receiver at 100 °C. Optical efficiency is presented normalized for laboratories showing standard deviations of 0.3 % to 1.3 % depending on the receiver.
Hurricane track forecast cones from fluctuations
Meuel, T.; Prado, G.; Seychelles, F.; Bessafi, M.; Kellay, H.
2012-01-01
Trajectories of tropical cyclones may show large deviations from predicted tracks leading to uncertainty as to their landfall location for example. Prediction schemes usually render this uncertainty by showing track forecast cones representing the most probable region for the location of a cyclone during a period of time. By using the statistical properties of these deviations, we propose a simple method to predict possible corridors for the future trajectory of a cyclone. Examples of this scheme are implemented for hurricane Ike and hurricane Jimena. The corridors include the future trajectory up to at least 50 h before landfall. The cones proposed here shed new light on known track forecast cones as they link them directly to the statistics of these deviations. PMID:22701776
Large Deviations and Transitions Between Equilibria for Stochastic Landau-Lifshitz-Gilbert Equation
NASA Astrophysics Data System (ADS)
Brzeźniak, Zdzisław; Goldys, Ben; Jegaraj, Terence
2017-11-01
We study a stochastic Landau-Lifshitz equation on a bounded interval and with finite dimensional noise. We first show that there exists a pathwise unique solution to this equation and that this solution enjoys the maximal regularity property. Next, we prove the large deviations principle for the small noise asymptotic of solutions using the weak convergence method. An essential ingredient of the proof is the compactness, or weak to strong continuity, of the solution map for a deterministic Landau-Lifschitz equation when considered as a transformation of external fields. We then apply this large deviations principle to show that small noise can cause magnetisation reversal. We also show the importance of the shape anisotropy parameter for reducing the disturbance of the solution caused by small noise. The problem is motivated by applications from ferromagnetic nanowires to the fabrication of magnetic memories.
Malu, Omojo O.; Kram, Yoseph A.; Song, Sungjin A.; Tolisano, Anthony M.; Kushida, Clete A.
2016-01-01
Objective. To systematically review the international literature for studies evaluating internal (NoZovent) and external (Breathe Right Strips) nasal dilators as treatment for obstructive sleep apnea (OSA). Study Design. Systematic review with meta-analysis. Methods. Four databases, including PubMed/MEDLINE, were searched through September 29, 2016. Results. One-hundred twelve studies were screened, fifty-eight studies were reviewed, and fourteen studies met criteria. In 147 patients, the apnea-hypopnea index (AHI) was reported, and there was an improvement from a mean ± standard deviation (M ± SD) of 28.7 ± 24.0 to 27.4 ± 23.3 events/hr, p value 0.64. There was no significant change in AHI, lowest oxygen saturation, or snoring index in OSA patients when using nasal dilators. However, a subanalysis demonstrated a slight reduction in apnea index (AI) with internal nasal dilators (decrease by 4.87 events/hr) versus minimal change for external nasal dilators (increase by 0.64 events/hr). Conclusion. Although nasal dilators have demonstrated improved nasal breathing, they have not shown improvement in obstructive sleep apnea outcomes, with the exception of mild improvement in apnea index when internal nasal dilators were used. PMID:28070421
Nonsteroidal Anti-Inflammatory Drugs and Bone-Healing: A Systematic Review of Research Quality.
Marquez-Lara, Alejandro; Hutchinson, Ian D; Nuñez, Fiesky; Smith, Thomas L; Miller, Anna N
2016-03-15
Nonsteroidal anti-inflammatory drugs (NSAIDs) are often avoided by orthopaedic surgeons because of their possible influence on bone-healing. This belief stems from multiple studies, in particular animal studies, that show delayed bone-healing or nonunions associated with NSAID exposure. The purpose of this review was to critically analyze the quality of published literature that evaluates the impact of NSAIDs on clinical bone-healing. A MEDLINE and Embase search was conducted to identify all articles relating to bone and fracture-healing and the utilization of NSAIDs. All human studies, including review articles, were identified for further analysis. Non-English-language manuscripts and in vitro and animal studies were excluded. A total of twelve clinical articles and twenty-four literature reviews were selected for analysis. The quality of the clinical studies was assessed with a modified Coleman Methodology Score with emphasis on the NSAID utilization. Review articles were analyzed with regard to variability in the cited literature and final conclusions. The mean modified Coleman Methodology Score (and standard deviation) was significantly lower (p = 0.032) in clinical studies that demonstrated a negative effect of NSAIDs on bone-healing (40.0 ± 14.3 points) compared with those that concluded that NSAIDs were safe (58.8 ± 10.3 points). Review articles also demonstrated substantial variability in the number of cited clinical studies and overall conclusions. There were only two meta-analyses and twenty-two narrative reviews. The mean number (and standard deviation) of clinical studies cited was significantly greater (p = 0.008) for reviews that concluded that NSAIDs were safe (8.0 ± 4.8) compared with those that recommended avoiding them (2.1 ± 2.1). Unanimously, all reviews admitted to the need for prospective randomized controlled trials to help clarify the effects of NSAIDs on bone-healing. This systematic literature review highlights the great variability in the interpretation of the literature addressing the impact of NSAIDs on bone-healing. Unfortunately, there is no consensus regarding the safety of NSAIDs following orthopaedic procedures, and future studies should aim for appropriate methodological designs to help to clarify existing discrepancies to improve the quality of care for orthopaedic patients. This systematic review highlights the limitations in the current understanding of the effects of NSAIDs on bone healing. Thus, withholding these medications does not have any proven scientific benefit to patients and may even cause harm by increasing narcotic requirements in cases in which they could be beneficial for pain management. This review should encourage further basic-science and clinical studies to clarify the risks and benefits of anti-inflammatory medications in the postoperative period, with the aim of improving patient outcomes.
Ahn, Jaechan; Kim, Sung-Jin; Lee, Ji-Yeon; Chung, Chooryung J; Kim, Kyung-Ho
2017-01-01
The purposes of this study were to compare the buccolingual inclinations of the posterior teeth in skeletal Class III patients with and without facial asymmetry with those of skeletal Class I patients and to investigate their relationships with sagittal and transverse skeletal discrepancies. Sixty-three skeletal Class III adult patients were divided into 2 groups according to the degree of menton deviation: a symmetry group with deviation less than 2 mm (n = 30), and an asymmetry group with deviation greater than 4 mm (n = 33). The control group comprised 25 skeletal Class I patients. The buccolingual inclinations of the posterior teeth measured on cone-beam computed tomography images were compared among the 3 groups, and regression analysis was performed to investigate the relationships between the inclinations and the sagittal and transverse skeletal discrepancies. The symmetry group showed greater buccal inclinations of the maxillary posterior teeth and lingual inclinations of the mandibular second molars than did the control, and this was correlated with the ANB angles. The deviated sides in the asymmetry group showed the greatest transverse dental compensation, which was correlated with menton deviation, whereas the nondeviated sides showed no significant transverse dental compensation. Transverse dental compensation is closely related to sagittal and transverse skeletal discrepancy in skeletal Class III patients. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Sub-grain induced crack deviation in multi-crystalline silicon
NASA Astrophysics Data System (ADS)
Zhao, Lv; Nelias, Daniel; Bardel, Didier; Wang, Meng; Marie, Benoit
2017-06-01
The fracture process in crystalline silicon is dictated by energy dissipation. Here, we show that sub-grains can deviate the crack path from the most energetically favorable ( 111) plane. Albeit a small misorientation across the sub-grain boundary is identified, upon entering into the sub-grain region, the crack either slightly deviates from the ideal ( 111) plane or directly chooses the secondly most favorable ( 110) one. We propose that the deviation is related to the dislocation core in the ( 111) crystal plane, which leads to a discontinuous atom debonding process and consequently a pronounced lattice trapping. In this circumstance, localized crystal defects prevail in the fracture process of silicon, while energetical criterion fails to interpret the crack path.
Using walker during walking: a pilot study for health elder.
Po-Chan, Yeh; Cherng-Yee, Leung
2012-01-01
Walker operation completely relies on the walker handle, however most marketed walkers possess two horizontal handles. Several researchers have suggested that horizontal handles might lead to wrist injury. Therefore, the purpose of this study is to assess the relevant design aspects of walker for elderly people. 28 elders participated in this study; when the experiment was started, subject walked on the tile for 3 meter distance twice by using walker. Data for analysis were selected at the corresponding wrist deviation and vertical force. The results showed that during walker using, the mean wrist deviation was greater than zero. The largest vertical force is significantly larger than the smallest one, and different wrist deviation occurred at three phases, the largest wrist deviation while raising walker is larger than the smallest one, however, no significant different was found between the largest and smallest wrist deviation while pressing walker. No significant correlation occurred between weight and wrist deviation. The correlation between weight and vertical force was significantly positive. With wrist deviation walker use may cause injury to upper-limb, however wrists remain in a neutral position during hand movement to prevent damage. The findings of this study should improve the design of walker handles to reduce the wrist deviations of users.
Differential processing of melodic, rhythmic and simple tone deviations in musicians--an MEG study.
Lappe, Claudia; Lappe, Markus; Pantev, Christo
2016-01-01
Rhythm and melody are two basic characteristics of music. Performing musicians have to pay attention to both, and avoid errors in either aspect of their performance. To investigate the neural processes involved in detecting melodic and rhythmic errors from auditory input we tested musicians on both kinds of deviations in a mismatch negativity (MMN) design. We found that MMN responses to a rhythmic deviation occurred at shorter latencies than MMN responses to a melodic deviation. Beamformer source analysis showed that the melodic deviation activated superior temporal, inferior frontal and superior frontal areas whereas the activation pattern of the rhythmic deviation focused more strongly on inferior and superior parietal areas, in addition to superior temporal cortex. Activation in the supplementary motor area occurred for both types of deviations. We also recorded responses to similar pitch and tempo deviations in a simple, non-musical repetitive tone pattern. In this case, there was no latency difference between the MMNs and cortical activation was smaller and mostly limited to auditory cortex. The results suggest that prediction and error detection of musical stimuli in trained musicians involve a broad cortical network and that rhythmic and melodic errors are processed in partially different cortical streams. Copyright © 2015 Elsevier Inc. All rights reserved.
Weinstein, Ronald S; Krupinski, Elizabeth A; Weinstein, John B; Graham, Anna R; Barker, Gail P; Erps, Kristine A; Holtrust, Angelette L; Holcomb, Michael J
2016-01-01
A medical school general pathology course has been reformatted into a K-12 general pathology course. This new course has been implemented at a series of 7 to 12 grade levels and the student outcomes compared. Typically, topics covered mirrored those in a medical school general pathology course serving as an introduction to the mechanisms of diseases. Assessment of student performance was based on their score on a multiple-choice final examination modeled after an examination given to medical students. Two Tucson area schools, in a charter school network, participated in the study. Statistical analysis of examination performances showed that there were no significant differences as a function of school ( F = 0.258, P = .6128), with students at school A having an average test scores of 87.03 (standard deviation = 8.99) and school B 86.00 (standard deviation = 8.18; F = 0.258, P = .6128). Analysis of variance was also conducted on the test scores as a function of gender and class grade. There were no significant differences as a function of gender ( F = 0.608, P = .4382), with females having an average score of 87.18 (standard deviation = 7.24) and males 85.61 (standard deviation = 9.85). There were also no significant differences as a function of grade level ( F = 0.627, P = .6003), with 7th graders having an average of 85.10 (standard deviation = 8.90), 8th graders 86.00 (standard deviation = 9.95), 9th graders 89.67 (standard deviation = 5.52), and 12th graders 86.90 (standard deviation = 7.52). The results demonstrated that middle and upper school students performed equally well in K-12 general pathology. Student course evaluations showed that the course met the student's expectations. One class voted K-12 general pathology their "elective course-of-the-year."
Flexner 3.0—Democratization of Medical Knowledge for the 21st Century
Krupinski, Elizabeth A.; Weinstein, John B.; Graham, Anna R.; Barker, Gail P.; Erps, Kristine A.; Holtrust, Angelette L.; Holcomb, Michael J.
2016-01-01
A medical school general pathology course has been reformatted into a K-12 general pathology course. This new course has been implemented at a series of 7 to 12 grade levels and the student outcomes compared. Typically, topics covered mirrored those in a medical school general pathology course serving as an introduction to the mechanisms of diseases. Assessment of student performance was based on their score on a multiple-choice final examination modeled after an examination given to medical students. Two Tucson area schools, in a charter school network, participated in the study. Statistical analysis of examination performances showed that there were no significant differences as a function of school (F = 0.258, P = .6128), with students at school A having an average test scores of 87.03 (standard deviation = 8.99) and school B 86.00 (standard deviation = 8.18; F = 0.258, P = .6128). Analysis of variance was also conducted on the test scores as a function of gender and class grade. There were no significant differences as a function of gender (F = 0.608, P = .4382), with females having an average score of 87.18 (standard deviation = 7.24) and males 85.61 (standard deviation = 9.85). There were also no significant differences as a function of grade level (F = 0.627, P = .6003), with 7th graders having an average of 85.10 (standard deviation = 8.90), 8th graders 86.00 (standard deviation = 9.95), 9th graders 89.67 (standard deviation = 5.52), and 12th graders 86.90 (standard deviation = 7.52). The results demonstrated that middle and upper school students performed equally well in K-12 general pathology. Student course evaluations showed that the course met the student’s expectations. One class voted K-12 general pathology their “elective course-of-the-year.” PMID:28725762
Misperceptions in the Trajectories of Objects undergoing Curvilinear Motion
Yilmaz, Ozgur; Tripathy, Srimant P.; Ogmen, Haluk
2012-01-01
Trajectory perception is crucial in scene understanding and action. A variety of trajectory misperceptions have been reported in the literature. In this study, we quantify earlier observations that reported distortions in the perceived shape of bilinear trajectories and in the perceived positions of their deviation. Our results show that bilinear trajectories with deviation angles smaller than 90 deg are perceived smoothed while those with deviation angles larger than 90 degrees are perceived sharpened. The sharpening effect is weaker in magnitude than the smoothing effect. We also found a correlation between the distortion of perceived trajectories and the perceived shift of their deviation point. Finally, using a dual-task paradigm, we found that reducing attentional resources allocated to the moving target causes an increase in the perceived shift of the deviation point of the trajectory. We interpret these results in the context of interactions between motion and position systems. PMID:22615775
A deviation display method for visualising data in mobile gamma-ray spectrometry.
Kock, Peder; Finck, Robert R; Nilsson, Jonas M C; Ostlund, Karl; Samuelsson, Christer
2010-09-01
A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded (137)Cs and (241)Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialization time of about 10min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.
Kessler, Thomas; Neumann, Jörg; Mummendey, Amélie; Berthold, Anne; Schubert, Thomas; Waldzus, Sven
2010-09-01
To explain the determinants of negative behavior toward deviants (e.g., punishment), this article examines how people evaluate others on the basis of two types of standards: minimal and maximal. Minimal standards focus on an absolute cutoff point for appropriate behavior; accordingly, the evaluation of others varies dichotomously between acceptable or unacceptable. Maximal standards focus on the degree of deviation from that standard; accordingly, the evaluation of others varies gradually from positive to less positive. This framework leads to the prediction that violation of minimal standards should elicit punishment regardless of the degree of deviation, whereas punishment in response to violations of maximal standards should depend on the degree of deviation. Four studies assessed or manipulated the type of standard and degree of deviation displayed by a target. Results consistently showed the expected interaction between type of standard (minimal and maximal) and degree of deviation on punishment behavior.
Endometrioid adenocarcinoma of the uterus with a minimal deviation invasive pattern.
Landry, D; Mai, K T; Senterman, M K; Perkins, D G; Yazdi, H M; Veinot, J P; Thomas, J
2003-01-01
Minimal deviation adenocarcinoma of endometrioid type is a rare pathological entity. We describe a variant of typical endometrioid adenocarcinoma associated with minimal deviation adenocarcinoma of endometrioid type. One 'pilot' case of minimal deviation adenocarcinoma of endometrioid type associated with typical endometrioid adenocarcinoma was encountered at our institution in 2001. A second case of same type was received in consultation. We reviewed 168 consecutive hysterectomy specimens diagnosed with 'endometrioid adenocarcinoma' specifically to identify areas of minimal deviation adenocarcinoma of endometrioid type. Immunohistochemistry was done with the following antibodies: MIB1, p53, oestrogen receptor (ER), progesterone receptor (PR), cytokeratin 7 (CK7), cytokeratin 20 (CK20), carcinoembryonic antigen (CEA), and vimentin (VIM). Four additional cases of minimal deviation adenocarcinoma of endometrioid type were identified. All six cases of minimal deviation adenocarcinoma of endometrioid type were associated with superficial endometrioid adenocarcinoma. In two cases with a large amount of minimal deviation adenocarcinoma of endometrioid type, the cervix was involved. The immunoprofile of two representative cases was ER+, PR+, CK7+, CK20-, CEA-, VIM+. MIB1 immunostaining of four cases revealed little proliferative activity of the minimal deviation adenocarcinoma of endometrioid type glandular cells (0-1%) compared with the associated 'typical' endometrioid adenocarcinoma (20-30%). The same four cases showed no p53 immunostaining in minimal deviation adenocarcinoma of endometrioid type compared with a range of positive staining in the associated endometrioid adenocarcinoma. Minimal deviation adenocarcinoma of endometrioid type more often develops as a result of differentiation from typical endometrioid adenocarcinoma than de novo. Due to its deceptively benign microscopic appearance, minimal deviation adenocarcinoma of endometrioid type may be overlooked and may lead to incorrect assessment of tumour depth and pathological stage. There was a tendency for tumour with a large amount of minimal deviation adenocarcinoma of endometrioid type to invade the cervix.
A Correlational Study of Scoliosis and Trunk Balance in Adult Patients with Mandibular Deviation
Yang, Yang; Wang, Na; Wang, Wenyong; Ding, Yin; Sun, Shiyao
2013-01-01
Previous studies have confirmed that patients with mandibular deviation often have abnormal morphology of their cervical vertebrae. However, the relationship between mandibular deviation, scoliosis, and trunk balance has not been studied. Currently, mandibular deviation is usually treated as a single pathology, which leads to poor clinical efficiency. We investigated the relationship of spine coronal morphology and trunk balance in adult patients with mandibular deviation, and compared the finding to those in healthy volunteers. 35 adult patients with skeletal mandibular deviation and 10 healthy volunteers underwent anterior X-ray films of the head and posteroanterior X-ray films of the spine. Landmarks and lines were drawn and measured on these films. The axis distance method was used to measure the degree of scoliosis and the balance angle method was used to measure trunk balance. The relationship of mandibular deviation, spine coronal morphology and trunk balance was evaluated with the Pearson correlation method. The spine coronal morphology of patients with mandibular deviation demonstrated an “S” type curve, while a straight line parallel with the gravity line was found in the control group (significant difference, p<0.01). The trunk balance of patients with mandibular deviation was disturbed (imbalance angle >1°), while the control group had a normal trunk balance (imbalance angle <1°). There was a significant difference between the two groups (p<0.01). The degree of scoliosis and shoulder imbalance correlated with the degree of mandibular deviation, and presented a linear trend. The direction of mandibular deviation was the same as that of the lateral bending of thoracolumbar vertebrae, which was opposite to the direction of lateral bending of cervical vertebrae. Our study shows the degree of mandibular deviation has a high correlation with the degree of scoliosis and trunk imbalance, all the three deformities should be clinically evaluated in the management of mandibular deviation. PMID:23555836
SU-E-T-506: Intercomparison Study On Small Field Output Factor Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Talamonti, C; Casati, M; Compagnucci, A
2015-06-15
Purpose In radiotherapy, uncertainties due to small field measurements (SFM) introduce systematic errors to the treatment process and the development of new dosimeters for quality assurance programs is a challenge. In this work we analyze the behavior of seven detectors measuring output factors of 6MV photon beam. Methods The dosimeters employed are: a single cristal diamond detector (SCCD) developed at the University of Rome Tor Vergata, a silicon diode developed within the project MAESTRO, a IBA Razor silicon diode, A1SL and A26 Exradin ion chambers, an EBT3 Gafchromic film and the Exradin W1 Scintillator.Diamond sensitive volume is a cylinder 2.2mmmore » in diameter and 1μm thick. MAESTRO diode is 2×2mm2 active area. Razor sensitive volume is a cylinder 0.6 mm in diameter and 0.02 mm thick. A16 and A1Sl have a collecting volume of 0,015cc and 0,053cc. The W1 is an optical fiber with an active volume of 0.002cc. All measurements were performed in a water phantom, with detector positioned at the isocenter (SSD=90cm, d=10cm), MAESTRO diode being sandwiched in solid water to obtain an equivalent experimental setup. Results These measurements are challenging due to the absence of charged particle equilibrium conditions, detector size and positioning problems. They are in good agreement among each other, especially GAF, Razor, W1 and SCDD. Maximum deviations reported are related to the field 0.8×0.8cm2 for MAESTRO and chambers data with respect to EBT3: around 15% (A1SLvsEBT3), 16% (MAESTROvsEBT3). Razor and W1 show a deviation around 3% with respect to SCDD. Conclusion In this work measurements made with a variety of detectors are compared. These study show the possibility to choose different detectors for SFM and that smaller ion chambers are still not competitive with solid state detectors. Silicon, diamond and optical fiber dosimeters show a similar behavior with minor discrepancies for the smallest field.« less
Fabbiani, Massimiliano; Di Giambenedetto, Simona; Cingolani, Antonella; Fanti, Iuri; Colafigli, Manuela; Tamburrini, Enrica; Cauda, Roberto; Navarra, Pierluigi; De Luca, Andrea; Murri, Rita
2016-01-01
The aim of the study was to explore relationships between self-reported adherence, antiretroviral drug concentration measurement (TDM) and self-reported symptoms. We systematically administered to human immunodeficiency (HIV)-infected outpatients a questionnaire evaluating measures of self-reported adherence (missing doses during last week, deviations from the prescribed timing of therapy, self-initiated discontinuations for > 24 or 48 h, exhausting drugs and present sense of how patients are taking therapy) and a panel of referred symptoms (a symptom score was built summing self-reported scores for each listed symptom). We selected patients who completed the questionnaire and also had a TDM (mainly reflecting adherence in the past few days or weeks), thus comparing these two tools as measures of adherence. A total of 130 patients (64.6% males, median age 44 years, 76.2% with HIV RNA < 50 copies/ml, median CD4 540 cells/μl) were included. Mean self-reported adherence (on a 0-100 visual analogue scale) was 80% (standard deviation, 18.7). Drug concentration was subtherapeutic in 16 patients (12.3%), of which 7 (5.4%) had undetectable drug levels (< 0.05 mg/L). Of these last seven patients, five (71.4%) reported an adherence below 80%. In a multivariable analysis, females and patients with undetectable drug levels (mean change -18.43%, 95% confidence intervals (CIs) -31.83 to -5.03, p = 0.007) showed a lower self-reported adherence, while those with HIV RNA < 50 copies/ml showed a higher adherence. Lower self-reported adherence (odds ratio 0.62 per 10% increase, 95% CI = 0.43-0.89, p = 0.009) and longer time from last drug intake were independently related to the development of undetectable drug levels. We also found that a higher symptom score was associated with a lower self-reported adherence and with a higher proportion of undetectable drug levels. Self-reported adherence and TDM showed a correlation and seemed to be comparable tools for adherence estimation. Self-reported symptoms were associated with lower adherence and undetectable drug levels.
Rational models as theories - not standards - of behavior.
McKenzie, Craig R.M.
2003-09-01
When people's behavior in laboratory tasks systematically deviates from a rational model, the implication is that real-world performance could be improved by changing the behavior. However, recent studies suggest that behavioral violations of rational models are at least sometimes the result of strategies that are well adapted to the real world (and not necessarily to the laboratory task). Thus, even if one accepts that certain behavior in the laboratory is irrational, compelling evidence that real-world behavior ought to change accordingly is often lacking. It is suggested here that rational models be seen as theories, and not standards, of behavior.
Perceptions of midline deviations among different facial types.
Williams, Ryan P; Rinchuse, Daniel J; Zullo, Thomas G
2014-02-01
The correction of a deviated midline can involve complicated mechanics and a protracted treatment. The threshold below which midline deviations are considered acceptable might depend on multiple factors. The objective of this study was to evaluate the effect of facial type on laypersons' perceptions of various degrees of midline deviation. Smiling photographs of male and female subjects were altered to create 3 facial type variations (euryprosopic, mesoprosopic, and leptoprosopic) and deviations in the midline ranging from 0.0 to 4.0 mm. Evaluators rated the overall attractiveness and acceptability of each photograph. Data were collected from 160 raters. The overall threshold for the acceptability of a midline deviation was 2.92 ± 1.10 mm, with the threshold for the male subject significantly lower than that for the female subject. The euryprosopic facial type showed no decrease in mean attractiveness until the deviations were 2 mm or more. All other facial types were rated as decreasingly attractive from 1 mm onward. Among all facial types, the attractiveness of the male subject was only affected at deviations of 2 mm or greater; for the female subject, the attractiveness scores were significantly decreased at 1 mm. The mesoprosopic facial type was most attractive for the male subject but was the least attractive for the female subject. Facial type and sex may affect the thresholds at which a midline deviation is detected and above which a midline deviation is considered unacceptable. Both the euryprosopic facial type and male sex were associated with higher levels of attractiveness at relatively small levels of deviations. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Outcome reporting following navigated high tibial osteotomy of the knee: a systematic review.
Yan, James; Musahl, Volker; Kay, Jeffrey; Khan, Moin; Simunovic, Nicole; Ayeni, Olufemi R
2016-11-01
This systematic review evaluates radiographic and clinical outcome reporting following navigated high tibial osteotomy (HTO). Conventional HTO was used as a control to compare outcomes and furthermore investigate the quality of evidence in studies reporting outcomes for navigated HTO. It was hypothesized that navigated HTO will show superior clinical and radiographic outcomes compared to conventional HTO. Two independent reviewers searched PubMed, Ovid (MEDLINE), EMBASE, and Cochrane databases for studies reporting outcomes following navigated HTO. Titles, abstracts, and full-text were screened in duplicate using an a priori inclusion and exclusion criteria. Descriptive statistics were calculated using Minitab ® statistical software. Methodological Index for Nonrandomized Studies (MINORS) and Cochrane Risk of Bias Scores were used to evaluate methodological quality. Thirty-four studies which involved 2216 HTOs were analysed in this review, 1608 (72.6 %) navigated HTOs and 608 (27.4 %) conventional HTOs. The majority of studies were of level IV evidence (16). Clinical outcomes were reported in knee and function scores or range of motion comparisons. Postoperative clinical and functional scores were improved by navigated HTO although it is not demonstrated if there is significant improvement compared to conventional HTO. Most common clinical outcome score reported was Lysholm scores (6) which report postoperative scores of 87.8 (standard deviation 5.9) and 88.8 (standard deviation 5.9) for conventional and navigation-assisted HTO, respectively. Radiographic outcomes reported commonly were weight-bearing mechanical axis, coronal plane angle, and posterior tibial slope angle in the sagittal plane. Studies have shown HTO gives significant correction of mechanical alignment and navigated HTO produces significantly less change in posterior tibial slope postoperatively compared to conventional. The mean MINORS for the 17 non-comparative studies was 9/16, and 15/24 for the 14 non-randomized comparative studies. Navigation HTO results in improved mechanical axis alignment and demonstrates significantly better control over the tibial slope angle change postoperatively compared to conventional methods; however, these improvements have not yet been reflected in clinical outcome scores. Overall the studies report HTO does create significantly improved knee scores and functions compared to patients' preoperative ratings regardless of technique. Future studies on HTO outcomes need to focus on consistency of outcome reporting. IV.
Preparation and purification of organic samples for selenium isotope studies.
Banning, Helena; Stelling, Monika; König, Stephan; Schoenberg, Ronny; Neumann, Thomas
2018-01-01
Selenium (Se) is an important micronutrient but also a strong toxin with a narrow tolerance range for many organisms. As such, a globally heterogeneous Se distribution in soils is responsible for various disease patterns (i.e. Se excess and deficiency) and environmental problems, whereby plants play a key role for the Se entrance into the biosphere. Selenium isotope variations were proved to be a powerful tracer for redox processes and are therefore promising for the exploration of the species dependent Se metabolism in plants and the Se cycling within the Critical Zone. Plant cultivation setups enable systematic controlled investigations, but samples derived from them-plant tissue and phytoagar-are particularly challenging and require specific preparation and purification steps to ensure precise and valid Se isotope analytics performed with HG-MC-ICP-MS. In this study, different methods for the entire process from solid tissue preparation to Se isotope measurements were tested, optimized and validated. A particular microwave digestion procedure for plant tissue and a vacuum filtration method for phytoagar led to full Se recoveries, whereby unfavorable organic residues were reduced to a minimum. Three purification methods predominantly described in the literature were systematically tested with pure Se solution, high concentrated multi-element standard solution as well as plant and phytoagar as target matrices. All these methods efficiently remove critical matrix elements, but differ in Se recovery and organic residues. Validation tests doping Se-free plant material and phytoagar with a reference material of known Se isotope composition revealed the high impact of organic residues on the accuracy of MC-ICP-MS measurements. Only the purification method with no detectable organic residues, hydride generation and trapping, results in valid mass bias correction for plant samples with an average deviation to true δ82/76Se values of 0.2 ‰ and a reproducibility (2 SD) of ± 0.2 ‰. For phytoagar this test yields a higher deviation of 1.1 ‰ from the true value and a 2 SD of ± 0.1 ‰. The application of the developed methods to cultivated plants shows sufficient accuracy and precision and is a promising approach to resolve plant internal Se isotope fractionations, for which respective δ82/76Se values of +2.3 to +3.5 ‰ for selenate and +1.2 to +1.9 ‰ for selenite were obtained.
Preparation and purification of organic samples for selenium isotope studies
Stelling, Monika; König, Stephan; Schoenberg, Ronny; Neumann, Thomas
2018-01-01
Selenium (Se) is an important micronutrient but also a strong toxin with a narrow tolerance range for many organisms. As such, a globally heterogeneous Se distribution in soils is responsible for various disease patterns (i.e. Se excess and deficiency) and environmental problems, whereby plants play a key role for the Se entrance into the biosphere. Selenium isotope variations were proved to be a powerful tracer for redox processes and are therefore promising for the exploration of the species dependent Se metabolism in plants and the Se cycling within the Critical Zone. Plant cultivation setups enable systematic controlled investigations, but samples derived from them–plant tissue and phytoagar–are particularly challenging and require specific preparation and purification steps to ensure precise and valid Se isotope analytics performed with HG-MC-ICP-MS. In this study, different methods for the entire process from solid tissue preparation to Se isotope measurements were tested, optimized and validated. A particular microwave digestion procedure for plant tissue and a vacuum filtration method for phytoagar led to full Se recoveries, whereby unfavorable organic residues were reduced to a minimum. Three purification methods predominantly described in the literature were systematically tested with pure Se solution, high concentrated multi-element standard solution as well as plant and phytoagar as target matrices. All these methods efficiently remove critical matrix elements, but differ in Se recovery and organic residues. Validation tests doping Se-free plant material and phytoagar with a reference material of known Se isotope composition revealed the high impact of organic residues on the accuracy of MC-ICP-MS measurements. Only the purification method with no detectable organic residues, hydride generation and trapping, results in valid mass bias correction for plant samples with an average deviation to true δ82/76Se values of 0.2 ‰ and a reproducibility (2 SD) of ± 0.2 ‰. For phytoagar this test yields a higher deviation of 1.1 ‰ from the true value and a 2 SD of ± 0.1 ‰. The application of the developed methods to cultivated plants shows sufficient accuracy and precision and is a promising approach to resolve plant internal Se isotope fractionations, for which respective δ82/76Se values of +2.3 to +3.5 ‰ for selenate and +1.2 to +1.9 ‰ for selenite were obtained. PMID:29509798
NASA Astrophysics Data System (ADS)
Li, Xiaoliang; Luo, Lei; Li, Pengwei; Yu, Qingkui
2018-03-01
The image sensor in satellite optical communication system may generate noise due to space irradiation damage, leading to deviation for the determination of the light spot centroid. Based on the irradiation test data of CMOS devices, simulated defect spots in different sizes have been used for calculating the centroid deviation value by grey-level centroid algorithm. The impact on tracking & pointing accuracy of the system has been analyzed. The results show that both the amount and the position of irradiation-induced defect pixels contribute to spot centroid deviation. And the larger spot has less deviation. At last, considering the space radiation damage, suggestions are made for the constraints of spot size selection.
Mani, Ganesh Kadirampatti; Karunakaran, Kaviarasu
2016-01-01
Small fields smaller than 4×4 cm2 are used in stereotactic and conformal treatments where heterogeneity is normally present. Since dose calculation accuracy in both small fields and heterogeneity often involves more discrepancy, algorithms used by treatment planning systems (TPS) should be evaluated for achieving better treatment results. This report aims at evaluating accuracy of four model‐based algorithms, X‐ray Voxel Monte Carlo (XVMC) from Monaco, Superposition (SP) from CMS‐Xio, AcurosXB (AXB) and analytical anisotropic algorithm (AAA) from Eclipse are tested against the measurement. Measurements are done using Exradin W1 plastic scintillator in Solid Water phantom with heterogeneities like air, lung, bone, and aluminum, irradiated with 6 and 15 MV photons of square field size ranging from 1 to 4 cm2. Each heterogeneity is introduced individually at two different depths from depth‐of‐dose maximum (Dmax), one setup being nearer and another farther from the Dmax. The central axis percentage depth‐dose (CADD) curve for each setup is measured separately and compared with the TPS algorithm calculated for the same setup. The percentage normalized root mean squared deviation (%NRMSD) is calculated, which represents the whole CADD curve's deviation against the measured. It is found that for air and lung heterogeneity, for both 6 and 15 MV, all algorithms show maximum deviation for field size 1×1 cm2 and gradually reduce when field size increases, except for AAA. For aluminum and bone, all algorithms' deviations are less for 15 MV irrespective of setup. In all heterogeneity setups, 1×1 cm2 field showed maximum deviation, except in 6 MV bone setup. All algorithms in the study, irrespective of energy and field size, when any heterogeneity is nearer to Dmax, the dose deviation is higher compared to the same heterogeneity far from the Dmax. Also, all algorithms show maximum deviation in lower‐density materials compared to high‐density materials. PACS numbers: 87.53.Bn, 87.53.kn, 87.56.bd, 87.55.Kd, 87.56.jf PMID:26894345
NASA Astrophysics Data System (ADS)
Shirmohamadi, Mohamad; Kadkhodaie, Ali; Rahimpour-Bonab, Hossain; Faraji, Mohammad Ali
2017-04-01
Velocity deviation log (VDL) is a synthetic log used to determine pore types in reservoir rocks based on a combination of the sonic log with neutron-density logs. The current study proposes a two step approach to create a map of porosity and pore types by integrating the results of petrographic studies, well logs and seismic data. In the first step, velocity deviation log was created from the combination of the sonic log with the neutron-density log. The results allowed identifying negative, zero and positive deviations based on the created synthetic velocity log. Negative velocity deviations (below - 500 m/s) indicate connected or interconnected pores and fractures, while positive deviations (above + 500 m/s) are related to isolated pores. Zero deviations in the range of [- 500 m/s, + 500 m/s] are in good agreement with intercrystalline and microporosities. The results of petrographic studies were used to validate the main pore type derived from velocity deviation log. In the next step, velocity deviation log was estimated from seismic data by using a probabilistic neural network model. For this purpose, the inverted acoustic impedance along with the amplitude based seismic attributes were formulated to VDL. The methodology is illustrated by performing a case study from the Hendijan oilfield, northwestern Persian Gulf. The results of this study show that integration of petrographic, well logs and seismic attributes is an instrumental way for understanding the spatial distribution of main reservoir pore types.
Perception of midline deviations in smile esthetics by laypersons.
Ferreira, Jamille Barros; Silva, Licínio Esmeraldo da; Caetano, Márcia Tereza de Oliveira; Motta, Andrea Fonseca Jardim da; Cury-Saramago, Adriana de Alcantara; Mucha, José Nelson
2016-01-01
To evaluate the esthetic perception of upper dental midline deviation by laypersons and if adjacent structures influence their judgment. An album with 12 randomly distributed frontal view photographs of the smile of a woman with the midline digitally deviated was evaluated by 95 laypersons. The frontal view smiling photograph was modified to create from 1 mm to 5 mm deviations in the upper midline to the left side. The photographs were cropped in two different manners and divided into two groups of six photographs each: group LCN included the lips, chin, and two-thirds of the nose, and group L included the lips only. The laypersons performed the rate of each smile using a visual analog scale (VAS). Wilcoxon test, Student's t-test and Mann-Whitney test were applied, adopting a 5% level of significance. Laypersons were able to perceive midline deviations starting at 1 mm. Statistically significant results (p< 0.05) were found for all multiple comparisons of the values in photographs of group LCN and for almost all comparisons in photographs of group L. Comparisons between the photographs of groups LCN and L showed statistically significant values (p< 0.05) when the deviation was 1 mm. Laypersons were able to perceive the upper dental midline deviations of 1 mm, and above when the adjacent structures of the smiles were included. Deviations of 2 mm and above when the lips only were included. The visualization of structures adjacent to the smile demonstrated influence on the perception of midline deviation.
A critical assessment of two types of personal UV dosimeters.
Seckmeyer, Gunther; Klingebiel, Marcus; Riechelmann, Stefan; Lohse, Insa; McKenzie, Richard L; Liley, J Ben; Allen, Martin W; Siani, Anna-Maria; Casale, Giuseppe R
2012-01-01
Doses of erythemally weighted irradiances derived from polysulphone (PS) and electronic ultraviolet (EUV) dosimeters have been compared with measurements obtained using a reference spectroradiometer. PS dosimeters showed mean absolute deviations of 26% with a maximum deviation of 44%, the calibrated EUV dosimeters showed mean absolute deviations of 15% (maximum 33%) around noon during several test days in the northern hemisphere autumn. In the case of EUV dosimeters, measurements with various cut-off filters showed that part of the deviation from the CIE erythema action spectrum was due to a small, but significant sensitivity to visible radiation that varies between devices and which may be avoided by careful preselection. Usually the method of calibrating UV sensors by direct comparison to a reference instrument leads to reliable results. However, in some circumstances the quality of measurements made with simple sensors may be over-estimated. In the extreme case, a simple pyranometer can be used as a UV instrument, providing acceptable results for cloudless skies, but very poor results under cloudy conditions. It is concluded that while UV dosimeters are useful for their design purpose, namely to estimate personal UV exposures, they should not be regarded as an inexpensive replacement for meteorological grade instruments. © 2011 Wiley Periodicals, Inc. Photochemistry and Photobiology © 2011 The American Society of Photobiology.
HF radar transmissions that deviate from great-circle paths: new insight from e-POP RRI
NASA Astrophysics Data System (ADS)
Perry, G. W.; Miller, E. S.; James, H. G.; Howarth, A. D.; St-Maurice, J. P.; Yau, A. W.
2016-12-01
Significant deviations of SuperDARN radar transmissions from their expected great-circle paths have been detected at ionospheric altitudes using the Radio Receiver Instrument (RRI) on the Enhanced Polar Outflow Probe (e-POP). Experiments between SuperDARN Rankin Inlet and e-POP RRI were conducted at similar local times over consecutive days. Customized experiment modes which incorporated the agile frequency switching capabilities of each system were used. The RRI measurements show deviations of radar transmissions from their expected paths by as much as 2 or 3 SuperDARN beam widths, equivalent to 6° - 10° in bearing from Rankin Inlet. The deviations displayed a dependence on the radar carrier frequency and a day-to-day variability, suggesting that the deviations were transient in nature. We will discuss the deviations in the context of 3D ray trace modeling and measurements from the Resolute Bay Incoherent Scatter Radar - North (RISR-N). The latter provided diagnostic information of the ionosphere along the ray path between RRI and Rankin Inlet during the experiments.
Gutman, Shawn; Kim, Daniel; Tarafder, Solaiman; Velez, Sergio; Jeong, Julia; Lee, Chang H
2018-02-01
To determine the regionally variant quality of collagen alignment in human TMJ discs and its statistical correlation with viscoelastic properties. For quantitative analysis of the quality of collagen alignment, horizontal sections of human TMJ discs with Pricrosirius Red staining were imaged under circularly polarized microscopy. Mean angle and angular deviation of collagen fibers in each region were analyzed using a well-established automated image-processing for angular gradient. Instantaneous and relaxation moduli of each disc region were measured under stress-relaxation test both in tensile and compression. Then Spearman correlation analysis was performed between the angular deviation and the moduli. To understand the effect of glycosaminoglycans on the correlation, TMJ disc samples were treated by chondroitinase ABC (C-ABC). Our imaging processing analysis showed the region-variant direction of collagen alignment, consistently with previous findings. Interestingly, the quality of collagen alignment, not only the directions, was significantly different in between the regions. The angular deviation of fiber alignment in the anterior and intermediate regions were significantly smaller than the posterior region. Medial and lateral regions showed significantly bigger angular deviation than all the other regions. The regionally variant angular deviation values showed statistically significant correlation with the tensile instantaneous modulus and the relaxation modulus, partially dependent on C-ABC treatment. Our findings suggest the region-variant degree of collagen fiber alignment is likely attributed to the heterogeneous viscoelastic properties of TMJ disc that may have significant implications in development of regenerative therapy for TMJ disc. Copyright © 2017 Elsevier Ltd. All rights reserved.
New Evidence on the Relationship Between Climate and Conflict
NASA Astrophysics Data System (ADS)
Burke, M.
2015-12-01
We synthesize a large new body of research on the relationship between climate and conflict. We consider many types of human conflict, ranging from interpersonal conflict -- domestic violence, road rage, assault, murder, and rape -- to intergroup conflict -- riots, coups, ethnic violence, land invasions, gang violence, and civil war. After harmonizing statistical specifications and standardizing estimated effect sizes within each conflict category, we implement a meta-analysis that allows us to estimate the mean effect of climate variation on conflict outcomes as well as quantify the degree of variability in this effect size across studies. Looking across more than 50 studies, we find that deviations from moderate temperatures and precipitation patterns systematically increase the risk of conflict, often substantially, with average effects that are highly statistically significant. We find that contemporaneous temperature has the largest average effect by far, with each 1 standard deviation increase toward warmer temperatures increasing the frequency of contemporaneous interpersonal conflict by 2% and of intergroup conflict by more than 10%. We also quantify substantial heterogeneity in these effect estimates across settings.
The Orbital Ephemeris of the Classical Nova RR Pictoris: Presence of a Third Body?
NASA Astrophysics Data System (ADS)
Vogt, N.; Schreiber, M. R.; Hambsch, F.-J.; Retamales, G.; Tappert, C.; Schmidtobreick, L.; Fuentes-Morales, I.
2017-01-01
The ex-nova RR Pic presents a periodic hump in its light curve which is considered to refer to its orbital period. By analyzing all available epochs of these hump maxima in the literature and then combining them with those from new light curves obtained in 2013 and 2014, we establish an unique cycle count scheme valid during the past 50 years and derive an ephemeris with the orbital period 0.145025959(15) days. The O—C diagram of this linear ephemeris reveals systematic deviations that could have different causes. One of them could be a light-travel-time effect caused by the presence of a hypothetical third body near the star/brown dwarf mass limit, with an orbital period of the order of 70 years. We also examine the difficulty of the problematic of detecting substellar or planetary companions of close red-dwarf white-dwarf binaries (including cataclysmic variables) and discuss other possible mechanisms responsible for the observed deviations in O—C. For RR Pic, we propose strategies to solve this question by new observations.
Fügener, Andreas; Schiffels, Sebastian; Kolisch, Rainer
2017-03-01
The planning of surgery durations is crucial for efficient usage of operating theaters. Both planning too long and too short durations for surgeries lead to undesirable consequences, e.g. idle time, overtime, or rescheduling of surgeries. We define these consequences as operating room inefficiency. The overall objective of planning surgery durations is to minimize expected operating room inefficiency, since surgery durations are stochastic. While most health care studies assume economically rational behavior of decision makers, experimental studies have shown that decision makers often do not act according to economic incentives. Based on insights from health care operations management, medical decision making, behavioral operations management, as well as empirical observations, we derive hypotheses that surgeons' behavior deviates from economically rational behavior. To investigate this, we undertake an experimental study where experienced surgeons are asked to plan surgeries with uncertain durations. We discover systematic deviations from optimal decision making and offer behavioral explanations for the observed biases. Our research provides new insights to tackle a major problem in hospitals, i.e. low operating room utilization going along with staff overtime.
Testing SgrA{sup *} with the spectrum of its accretion structure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Nan; Li, Zilong; Bambi, Cosimo
2015-09-01
SgrA{sup *} is the supermassive black hole candidate at the center of the Galaxy and an ideal laboratory to test general relativity. Following previous work by other authors, we use the Polish doughnut model to describe an optically thin and constant angular momentum ion torus in hydrodynamical equilibrium and model the accretion structure around SgrA{sup *}. The radiation mechanisms are bremsstrahlung, synchrotron emission, and inverse Compton scattering. We compute the spectrum as seen by a distant observer in Kerr and non-Kerr spacetimes and we study how an accurate measurement can constrain possible deviations form the Kerr solution. As in themore » case of emission from a thin accretion disk, we find a substantial degeneracy between the determination of the spin and of possible deviations from the Kerr geometry, even when the parameters of the ion torus are fixed. This means that this technique cannot independently test the nature of SgrA{sup *} even in the presence of good data and with the systematics under control. However, it might do it in combination with other measurements (black hole shadow, radio pulsar, etc.)« less
Differences in grip force control between young and late middle-aged adults.
Zheng, Lianrong; Li, Kunyang; Wang, Qian; Chen, Wenhui; Song, Rong; Liu, Guanzheng
2017-09-01
Grip force control is a crucial function for human to guarantee the quality of life. To examine the effects of age on grip force control, 10 young adults and 11 late middle-aged adults participated in visually guided tracking tasks using different target force levels (25, 50, and 75% of the subject's maximal grip force). Multiple measures were used to evaluate the tracking performance during force rising phase and force maintenance phase. The measurements include the rise time, fuzzy entropy, mean force percentage, coefficient of variation, and target deviation ratio. The results show that the maximal grip force was significantly lower in the late middle-aged adults than in the young adults. The time of rising phase was systematically longer among late middle-aged adults. The fuzzy entropy is a useful indicator for quantitating the force variability of the grip force signal at higher force levels. These results suggest that the late middle-aged adults applied a compensatory strategy that allow allows for sufficient time to reach the required grip force and reduce the impact of the early and subtle degenerative changes in hand motor function.
Tucker, Jalie A; Roth, David L; Vignolo, Mary J; Westfall, Andrew O
2009-04-01
Data were pooled from 3 studies of recently resolved community-dwelling problem drinkers to determine whether a behavioral economic index of the value of rewards available over different time horizons distinguished among moderation (n = 30), abstinent (n = 95), and unresolved (n = 77) outcomes. Moderation over 1- to 2-year prospective follow-up intervals was hypothesized to involve longer term behavior regulation processes than abstinence or relapse and to be predicted by more balanced preresolution monetary allocations between short-term and longer term objectives (i.e., drinking and saving for the future). Standardized odds ratios (ORs) based on changes in standard deviation units from a multinomial logistic regression indicated that increases on this "Alcohol-Savings Discretionary Expenditure" index predicted higher rates of abstinence (OR = 1.93, p = .004) and relapse (OR = 2.89, p < .0001) compared with moderation outcomes. The index had incremental utility in predicting moderation in complex models that included other established predictors. The study adds to evidence supporting a behavioral economic analysis of drinking resolutions and shows that a systematic analysis of preresolution spending patterns aids in predicting moderation.
Disseminated intracranial xanthoma disseminatum: a rare case report and review of literature.
Yang, Guang-Zhi; Li, Jing; Wang, Lu-Ping
2016-08-17
Xanthoma disseminatum (XD) is a rare benign histiocytic proliferating disease of non-Langerhans cell origin, which is clinically mainly characterized by cutaneous or mucous lesions. Although XD is acknowledged of one systematic disease, involvement of the central nervous system is quite rare. We presented one 34-year-old Chinese female with disseminated intracranial XD without cutaneous or oral mucosal papules and masses of the other organs. MR imaging displayed multiple heterogeneous masses with intense enhancement in the right frontal lobe, temporal lobe, corpus callosum, left cuneus, suprasellar region, and right cerebellum. Pathological examination showed a neoplastic lesion composed of plentiful epitheloid or spindle cells. The cell had pink cytoplasm of vacuolation and foam with deviated nucleus absent of atypia and mitosis. The histiocytic markers including CD163, CD11c, Mac387 and CD68 were positive, whereas S-100, CD1a, GFAP, CD21, CD23 and so on were negative immunohistochemically. Intracranial XD without systemic involvement was extremely rare, which was supposed to be considered in differential diagnosis with other neoplasms of histiocytic origin or gliomas.
Distinctive features of transport in topological insulators
NASA Astrophysics Data System (ADS)
Sacksteder, Vincent; Wu, Quansheng; Arnardottir, Kristin; Shelykh, Ivan; Kettemann, Stefan
2015-03-01
The surface states of a topological insulator in a fine-tuned magnetic field are ideal candidates for realizing a topological metal which is protected against disorder. Its signatures are (1) a conductance plateau in long wires and (2) a conductivity which always increases with sample size. We numerically show that the bulk substantially accelerates the conductance plateaus's decay in a magnetic field. It also reduces the effects of surface disorder and causes the magnitude of the surface conductivity and the magnetoconductivity to depend systematically on sample details such as doping and disorder strength. In addition, we predict a new signature of the topological state: at low temperatures the magnetoresistance will deviate strongly from the Hikami-Larkin-Nagaoka (HLN) formula. In this regime the magnetoresistance is dominated by scattering processes which wrap around the TI sample. The HLN formula's shoulder is replaced by a feature with a larger critical field magnetic strength that is caused by wrapping. Inside the wrapping regime the magnetoconductance will lose its dependence on temperature. This new topological signature should be visible in the same samples and temperatures where the Altshuler-Aronov-Spivak (AAS) effect has already been observed.
Theoretical Modeling of 99 Tc NMR Chemical Shifts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hall, Gabriel B.; Andersen, Amity; Washton, Nancy M.
Technetium (Tc) displays a rich chemistry due to the wide range of oxidation states (from -I to +VII) and ability to form coordination compounds. Determination of Tc speciation in complex mixtures is a major challenge, and 99Tc NMR spec-troscopy is widely used to probe chemical environments of Tc in odd oxidation states. However interpretation of the 99Tc NMR data is hindered by the lack of reference compounds. DFT computations can help fill this gap, but to date few com-putational studies have focused on 99Tc NMR of compounds and complexes. This work systematically evaluates the inclu-sion small percentages of Hartree-Fock exchangemore » correlation and relativistic effects in DFT computations to support in-terpretation of the 99Tc NMR spectra. Hybrid functionals are found to perform better than their pure GGA counterparts, and non-relativistic calculations have been found to generally show a lower mean absolute deviation from experiment. Overall non-relativistic PBE0 and B3PW91 calculations are found to most accurately predict 99Tc NMR chemical shifts.« less
Pérez-Vázquez, Francisco J; Orta-García, Sandra T; Ochoa-Martínez, Ángeles C; Pruneda-Álvarez, Lucia G; Ruiz-Vera, Tania; Jiménez-Avalos, Jorge Armando; González-Palomo, Ana K; Pérez-Maldonado, Iván N
2016-01-01
The aim of this study was to assess the levels of polybrominated diphenyl ethers (PBDEs) in soils from the city of San Luis Potosi in Mexico and perform an ecological and human health risk characterization. In order to confirm the presence of PBDEs, outdoor surface soil samples were collected and the concentrations of PBDEs in urban, industrial, agricultural, and brick kiln industry areas were determined. The mean total PBDEs levels obtained in the study sites were 25.0 ± 39.5 μg/kg (geometric mean ± standard deviation) in the brick kiln industry zone; 34.5 ± 36.0 μg/kg in the urban zone; 8.00 ± 7.10 μg/kg in the industrial zone and 16.6 ± 15.3 μg/kg in the agricultural zone. The ecological and human health risk characterization showed relatively low-hazard quotient values. However, the moderately high PBDEs levels found in soils highlight the necessity to establish a systematic monitoring process for PBDEs in environmental and biological samples.
Posture systematically alters ear-canal reflectance and DPOAE properties
Voss, Susan E.; Adegoke, Modupe F.; Horton, Nicholas J.; Sheth, Kevin N.; Rosand, Jonathan; Shera, Christopher A.
2010-01-01
Several studies have demonstrated that the auditory system is sensitive to changes in posture, presumably through changes in intracranial pressure (ICP) that in turn alter the intracochlear pressure, which affects the stiffness of the middle-ear system. This observation has led to efforts to develop an ear-canal based noninvasive diagnostic measure for monitoring ICP, which is currently monitored invasively via access through the skull or spine. Here, we demonstrate the effects of postural changes, and presumably ICP changes, on distortion product otoacoustic emissions (DPOAE) magnitude, DPOAE angle, and power reflectance. Measurements were made on 12 normal-hearing subjects in two postural positions: upright at 90 degrees and tilted at −45 degrees to the horizontal. Measurements on each subject were repeated five times across five separate measurement sessions. All three measures showed significant changes (p < 0.001) between upright and tilted for frequencies between 500 and 2000 Hz, and DPOAE angle changes were significant at all measured frequencies (500–4000 Hz). Intrasubject variability, assessed via standard deviations for each subject’s multiple measurements, were generally smaller in the upright position relative to the tilted position. PMID:20227475
Small Sample Sizes Yield Biased Allometric Equations in Temperate Forests
Duncanson, L.; Rourke, O.; Dubayah, R.
2015-01-01
Accurate quantification of forest carbon stocks is required for constraining the global carbon cycle and its impacts on climate. The accuracies of forest biomass maps are inherently dependent on the accuracy of the field biomass estimates used to calibrate models, which are generated with allometric equations. Here, we provide a quantitative assessment of the sensitivity of allometric parameters to sample size in temperate forests, focusing on the allometric relationship between tree height and crown radius. We use LiDAR remote sensing to isolate between 10,000 to more than 1,000,000 tree height and crown radius measurements per site in six U.S. forests. We find that fitted allometric parameters are highly sensitive to sample size, producing systematic overestimates of height. We extend our analysis to biomass through the application of empirical relationships from the literature, and show that given the small sample sizes used in common allometric equations for biomass, the average site-level biomass bias is ~+70% with a standard deviation of 71%, ranging from −4% to +193%. These findings underscore the importance of increasing the sample sizes used for allometric equation generation. PMID:26598233
Exploring the Nature of Galaxies with Abundance Gradient Anomalies in the SDSS-IV/MaNGA Survey
NASA Astrophysics Data System (ADS)
Keith, Celeste; Tremonti, Christy; Pace, Zach; Schaefer, Adam
2018-01-01
Disk galaxies are known to have radial oxygen abundance gradients with their centers being more chemically enriched than their outskirts. The steepness of the abundance gradient has recently been shown to correlate with galaxy stellar mass, on average. However, individual galaxies sometimes show pronounced deviations from the expected trends, such as flatter or steeper slopes than expected for their mass, abrupt changes in slope, or azimuthal asymmetries. Here we report on a systematic search for galaxies with abundance gradient anomalies using 2-D spectroscopy from the Sloan Digital Sky Survey IV MaNGA. We construct nebular oxygen and nitrogen abundance maps for 300 moderately inclined non-interacting disk galaxies and use visual inspection to identify the most interesting cases. We use this training set to develop an automated pipeline to flag galaxies with abundance anomalies from the larger MaNGA dataset for visual inspection. We combine the metallicity maps with kinematic data and measurements of the galaxies' local environments to better understand the processes that shape the radial abundance gradients of disk galaxies.
Tian, Chunqiu; Tan, Huarong; Gao, Liping; Shen, Huqin; Qi, Kezong
2011-11-01
A high performance capillary electrophoresis (HPCE) method was developed for the simultaneous determination of penicillin intermediate and penicillins in milk, including 6-amino-penicillanic acid (6-APA), penicillin G (PEN), ampicillin (AMP) and amoxicillin (AMO). The main parameters including the ion concentration and pH value of running buffer, separation voltage and column temperature were optimized systematically by orthogonal test. The four penicillins (PENs) were baseline separated within 4.5 min with the running buffer of 40 mmol/L potassium dihydrogen phosphate-20 mmol/L borax solution (pH 7.8), separation voltage of 28 kV and column temperature of 30 degrees C. The calibration curves showed good linearity in the range of 1.56 - 100 mg/L, and the correlation coefficients (r2) were between 0.9979 and 0.9998. The average recoveries at three spiked levels were in the range of 84.91% - 96.72% with acceptable relative standard deviations (RSDs) of 1.11% - 9.11%. The method is simple, fast, accurate and suitable for the determination of penicillins in real samples.
The character of pulse delays during radio bursts in the pulsar B0943+10
NASA Astrophysics Data System (ADS)
Suleymanova, S. A.; Pugachev, V. D.
2017-05-01
Results of a new series of observations of the anomalous pulsar B0943+10 carried out on the Large Scanning Antenna and DKR-1000 radio telescope of the Pushchino Radio Astronomy Observatory at 112 and 62 MHz, respectively, are presented. Several hundred pulse-arrival times (PATs) obtained on various days in 2013-2016 that correspond to the burst (B) mode emission are analyzed. A method for establishing the many-hour pulse shift in the emission window from 3.5-minute fragments is proposed. The delay of the mean pulse relative to the pre-calculated value follows an exponential law with a relaxation time of about 47 minutes. The pulse delay grows by 6 ms during the five hours following the onset of a burst. The random scatter of the residual PAT deviations is comparable to the amplitude of the systematic variations in these times over the lifetime of the B mode. These observations show that the character of the pulse delay as a function of time is the same at 112 and 62 MHz.
X-ray analysis of the galaxy group UGC 03957 beyond R200 with Suzaku
NASA Astrophysics Data System (ADS)
Thölken, Sophia; Lovisari, Lorenzo; Reiprich, Thomas H.; Hasenbusch, Jan
2016-07-01
Context. In the last few years, the outskirts of galaxy clusters have been studied in detail and the analyses have brought up interesting results such as indications of possible gas clumping and the breakdown of hydrostatic, thermal, and ionization equilibrium. These phenomena affect the entropy profiles of clusters, which often show deviations from the self-similar prediction around R200. However, significant uncertainties remain for groups of galaxies. In particular the question, of whether entropy profiles are similar to those of galaxy clusters. Aims: We investigated the gas properties of the galaxy group UGC 03957 up to 1.4 R200 ≈ 1.4 Mpc in four azimuthal directions with the Suzaku satellite. We checked for azimuthal symmetry and obtained temperature, entropy, density, and gas mass profiles. Previous studies point to deviations from equilibrium states at the outskirts of groups and clusters and so we studied the hydrodynamical status of the gas at these large radii. Methods: We performed a spectral analysis of five Suzaku observations of UGC 03957 with ~138 ks good exposure time in total and five Chandra snapshot observations for point source detection. We investigated systematic effects such as point spread function and uncertainties in the different background components, and performed a deprojection of the density and temperature profile. Results: We found a temperature drop of a factor of ~3 from the center to the outskirts that is consistent with previous results for galaxy clusters. The metal abundance profile shows a flat behavior towards large radii, which is a hint for galactic winds as the primary ICM enrichment process. The entropy profile is consistent with numerical simulations after applying a gas mass fraction correction. Feedback processes and AGN activity might be one explanation for entropy modification, imprinting out to larger radii in galaxy groups than in galaxy clusters. Previous analyses for clusters and groups often showed an entropy flattening or even a drop around ~ R200, which can be an indication of clumping or non-equilibrium states in the outskirts. Such entropy behavior is absent in UGC 03957. The gas mass fraction is well below the cosmic mean but rises above this value beyond R200, which could be a hint for deviations from hydrostatic equilibrium at these large radii. By measuring the abundance of the α-elements Si and S at intermediate radii we determined the relative number of different supernovae types and found that the abundance pattern can be described by a relative contribution of 80%-100% of core-collapse supernovae. This result is in agreement with previous measurements for galaxy groups.
Balderson, Michael; Brown, Derek; Johnson, Patricia; Kirkby, Charles
2016-01-01
The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic-based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for the different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Optimal strategy for polarization modulation in the LSPE-SWIPE experiment
NASA Astrophysics Data System (ADS)
Buzzelli, A.; de Bernardis, P.; Masi, S.; Vittorio, N.; de Gasperis, G.
2018-01-01
Context. Cosmic microwave background (CMB) B-mode experiments are required to control systematic effects with an unprecedented level of accuracy. Polarization modulation by a half wave plate (HWP) is a powerful technique able to mitigate a large number of the instrumental systematics. Aims: Our goal is to optimize the polarization modulation strategy of the upcoming LSPE-SWIPE balloon-borne experiment, devoted to the accurate measurement of CMB polarization at large angular scales. Methods: We departed from the nominal LSPE-SWIPE modulation strategy (HWP stepped every 60 s with a telescope scanning at around 12 deg/s) and performed a thorough investigation of a wide range of possible HWP schemes (either in stepped or continuously spinning mode and at different azimuth telescope scan-speeds) in the frequency, map and angular power spectrum domain. In addition, we probed the effect of high-pass and band-pass filters of the data stream and explored the HWP response in the minimal case of one detector for one operation day (critical for the single-detector calibration process). We finally tested the modulation performance against typical HWP-induced systematics. Results: Our analysis shows that some stepped HWP schemes, either slowly rotating or combined with slow telescope modulations, represent poor choices. Moreover, our results point out that the nominal configuration may not be the most convenient choice. While a large class of spinning designs provides comparable results in terms of pixel angle coverage, map-making residuals and BB power spectrum standard deviations with respect to the nominal strategy, we find that some specific configurations (e.g., a rapidly spinning HWP with a slow gondola modulation) allow a more efficient polarization recovery in more general real-case situations. Conclusions: Although our simulations are specific to the LSPE-SWIPE mission, the general outcomes of our analysis can be easily generalized to other CMB polarization experiments.
Validation of Caregiver-Centered Delirium Detection Tools: A Systematic Review.
Rosgen, Brianna; Krewulak, Karla; Demiantschuk, Danielle; Ely, E Wesley; Davidson, Judy E; Stelfox, Henry T; Fiest, Kirsten M
2018-04-18
To summarize the validity of caregiver-centered delirium detection tools in hospitalized adults and assess associated patient and caregiver outcomes. Systematic review. We searched MEDLINE, EMBASE, PsycINFO, CINAHL, and Scopus from inception to May 15, 2017. Hospitalized adults. Caregiver-centered delirium detection tools. We drafted a protocol from the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Two reviewers independently completed abstract and full-text review, data extraction, and quality assessment. We summarized findings using descriptive statistics including mean, median, standard deviation, range, frequencies (percentages), and Cohen's kappa. Studies that reported on the validity of caregiver-centered delirium detection tools or associated patient and caregiver outcomes and were cohort or cross-sectional in design were included. We reviewed 6,056 titles and abstracts, included 6 articles, and identified 6 caregiver-centered tools. All tools were designed to be administered in several minutes or less and had 11 items or fewer. Three tools were caregiver administered (completed independently by caregivers): Family Confusion Assessment Method (FAM-CAM), Informant Assessment of Geriatric Delirium (I-AGeD), and Sour Seven. Three tools were caregiver informed (administered by a healthcare professional using caregiver input): Single Question in Delirium (SQiD), Single Screening Question Delirium (SSQ-Delirium), and Stressful Caregiving Response to Experiences of Dying. Caregiver-administered tools had better psychometric properties (FAM-CAM sensitivity 75%, 95% confidence interval (CI)=35-95%, specificity 91%, 95% CI=74-97%; Sour Seven positive predictive value 89.5%, negative predictive value 90%) than caregiver-informed tools (SQiD: sensitivity 80%, 95% CI=28.4-99.5%; specificity 71%, 95% CI=41.9-91.6%; SSQ-Delirium sensitivity 79.6%, specificity 56.1%). Delirium detection is essential for appropriate delirium management. Caregiver-centered delirium detection tools show promise in improving delirium detection and associated patient and caregiver outcomes. Comparative studies using larger sample sizes and multiple centers are required to determine validity and reliability characteristics. © 2018, Copyright the Authors Journal compilation © 2018, The American Geriatrics Society.
Stevenson, Gareth P; Baker, Ruth E; Kennedy, Gareth F; Bond, Alan M; Gavaghan, David J; Gillow, Kathryn
2013-02-14
The potential-dependences of the rate constants associated with heterogeneous electron transfer predicted by the empirically based Butler-Volmer and fundamentally based Marcus-Hush formalisms are well documented for dc cyclic voltammetry. However, differences are often subtle, so, presumably on the basis of simplicity, the Butler-Volmer method is generally employed in theoretical-experimental comparisons. In this study, the ability of Large Amplitude Fourier Transform AC Cyclic Voltammetry to distinguish the difference in behaviour predicted by the two formalisms has been investigated. The focus of this investigation is on the difference in the profiles of the first to sixth harmonics, which are readily accessible when a large amplitude of the applied ac potential is employed. In particular, it is demonstrated that systematic analysis of the higher order harmonic responses in suitable kinetic regimes provides predicted deviations of Marcus-Hush from Butler-Volmer behaviour to be established from a single experiment under conditions where the background charging current is minimal.
NASA Astrophysics Data System (ADS)
Gonzalez-Fuentes, C.; Dumas, R. K.; García, C.
2018-01-01
A theoretical and experimental study of the influence of small offsets of the magnetic field (δH) on the measurement accuracy of the spectroscopic g-factor (g) and saturation magnetization (Ms) obtained by broadband ferromagnetic resonance (FMR) measurements is presented. The random nature of δH generates systematic and opposite sign deviations of the values of g and Ms with respect to their true values. A δH on the order of a few Oe leads to a ˜10% error of g and Ms for a typical range of frequencies employed in broadband FMR experiments. We propose a simple experimental methodology to significantly minimize the effect of δH on the fitted values of g and Ms, eliminating their apparent dependence in the range of frequencies employed. Our method was successfully tested using broadband FMR measurements on a 5 nm thick Ni80Fe20 film for frequencies ranging between 3 and 17 GHz.
Resolving the neutron lifetime puzzle
NASA Astrophysics Data System (ADS)
Mumm, Pieter
2018-05-01
Free electrons and protons are stable, but outside atomic nuclei, free neutrons decay into a proton, electron, and antineutrino through the weak interaction, with a lifetime of ∼880 s (see the figure). The most precise measurements have stated uncertainties below 1 s (0.1%), but different techniques, although internally consistent, disagree by 4 standard deviations given the quoted uncertainties. Resolving this “neutron lifetime puzzle” has spawned much experimental effort as well as exotic theoretical mechanisms, thus far without a clear explanation. On page 627 of this issue, Pattie et al. (1) present the most precise measurement of the neutron lifetime to date. A new method of measuring trapped neutrons in situ allows a more detailed exploration of one of the more pernicious systematic effects in neutron traps, neutron phase-space evolution (the changing orbits of neutrons in the trap), than do previous methods. The precision achieved, combined with a very different set of systematic uncertainties, gives hope that experiments such as this one can help resolve the current situation with the neutron lifetime.
H0, q0 and the local velocity field. [Hubble and deceleration constants in Big Bang expansion
NASA Technical Reports Server (NTRS)
Sandage, A.; Tammann, G. A.
1982-01-01
An attempt is made to find a systematic deviation from linearity for distances that are under the control of the Virgo cluster, and to determine the value of the mean random motion about the systematic flow, in order to improve the measurement of the Hubble and the deceleration constants. The velocity-distance relation for large and intermediate distances is studied, and type I supernovae are calibrated relatively as distance indicators and absolutely to obtain a new value for the Hubble constant. Methods of determining the deceleration constant are assessed, including determination from direct measurement, mean luminosity density, virgocentric motion, and the time scale test. The very local velocity field is investigated, and a solution is preferred with a random peculiar radial velocity of very nearby field galaxies of 90-100 km/s, and a Virgocentric motion of the local group of 220 km/s, leading to an underlying expansion rate of 55, in satisfactory agreement with the global value.
Peest, Christian; Schinke, Carsten; Brendel, Rolf; Schmidt, Jan; Bothe, Karsten
2017-01-01
Spectrophotometers are operated in numerous fields of science and industry for a variety of applications. In order to provide confidence for the measured data, analyzing the associated uncertainty is valuable. However, the uncertainty of the measurement results is often unknown or reduced to sample-related contributions. In this paper, we describe our approach for the systematic determination of the measurement uncertainty of the commercially available two-channel spectrophotometer Agilent Cary 5000 in accordance with the Guide to the expression of uncertainty in measurements. We focus on the instrumentation-related uncertainty contributions rather than the specific application and thus outline a general procedure which can be adapted for other instruments. Moreover, we discover a systematic signal deviation due to the inertia of the measurement amplifier and develop and apply a correction procedure. Thereby we increase the usable dynamic range of the instrument by more than one order of magnitude. We present methods for the quantification of the uncertainty contributions and combine them into an uncertainty budget for the device.
A Statistical Analysis of Reviewer Agreement and Bias in Evaluating Medical Abstracts 1
Cicchetti, Domenic V.; Conn, Harold O.
1976-01-01
Observer variability affects virtually all aspects of clinical medicine and investigation. One important aspect, not previously examined, is the selection of abstracts for presentation at national medical meetings. In the present study, 109 abstracts, submitted to the American Association for the Study of Liver Disease, were evaluated by three “blind” reviewers for originality, design-execution, importance, and overall scientific merit. Of the 77 abstracts rated for all parameters by all observers, interobserver agreement ranged between 81 and 88%. However, corresponding intraclass correlations varied between 0.16 (approaching statistical significance) and 0.37 (p < 0.01). Specific tests of systematic differences in scoring revealed statistically significant levels of observer bias on most of the abstract components. Moreover, the mean differences in interobserver ratings were quite small compared to the standard deviations of these differences. These results emphasize the importance of evaluating the simple percentage of rater agreement within the broader context of observer variability and systematic bias. PMID:997596
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brahlek, Matthew; Zhang, Lei; Eaton, Craig
Stoichiometric SrVO{sub 3} thin films were grown over a range of cation fluxes on (001) (La{sub 0.3}Sr{sub 0.7})(Al{sub 0.65}Ta{sub 0.35})O{sub 3} substrates using hybrid molecular beam epitaxy, where a thermal effusion cell was employed to generate a Sr flux and V was supplied using the metal-organic precursor vanadium oxytriisopropoxide (VTIP). By systematically varying the VTIP flux while keeping the Sr flux constant, a range of flux ratios were discovered in which the structural and electronic properties of the SrVO{sub 3} films remained unaltered. The intrinsic film lattice parameter and residual resistivity were found to be the smallest inside the growthmore » window, indicating the lowest defect concentration of the films, and rapidly increased for cation flux ratios deviating from ideal growth condition. Reflection high-energy electron diffraction showed that films grown within this range had smooth surfaces and diffraction patterns were free of additional spots, while otherwise the growing surface was rough and contained additional crystalline phases. Results show the existence of a SrVO{sub 3} growth window at sufficiently high growth temperature, in which high-quality, stoichiometric films can be grown in a robust, highly reproducible manner that is invulnerable to unintentional flux variation.« less
On the basis set convergence of electron–electron entanglement measures: helium-like systems
Hofer, Thomas S.
2013-01-01
A systematic investigation of three different electron–electron entanglement measures, namely the von Neumann, the linear and the occupation number entropy at full configuration interaction level has been performed for the four helium-like systems hydride, helium, Li+ and Be2+ using a large number of different basis sets. The convergence behavior of the resulting energies and entropies revealed that the latter do in general not show the expected strictly monotonic increase upon increase of the one–electron basis. Overall, the three different entanglement measures show good agreement among each other, the largest deviations being observed for small basis sets. The data clearly demonstrates that it is important to consider the nature of the chemical system when investigating entanglement phenomena in the framework of Gaussian type basis sets: while in case of hydride the use of augmentation functions is crucial, the application of core functions greatly improves the accuracy in case of cationic systems such as Li+ and Be2+. In addition, numerical derivatives of the entanglement measures with respect to the nucleic charge have been determined, which proved to be a very sensitive probe of the convergence leading to qualitatively wrong results (i.e., the wrong sign) if too small basis sets are used. PMID:24790952
On the basis set convergence of electron-electron entanglement measures: helium-like systems.
Hofer, Thomas S
2013-01-01
A systematic investigation of three different electron-electron entanglement measures, namely the von Neumann, the linear and the occupation number entropy at full configuration interaction level has been performed for the four helium-like systems hydride, helium, Li(+) and Be(2+) using a large number of different basis sets. The convergence behavior of the resulting energies and entropies revealed that the latter do in general not show the expected strictly monotonic increase upon increase of the one-electron basis. Overall, the three different entanglement measures show good agreement among each other, the largest deviations being observed for small basis sets. The data clearly demonstrates that it is important to consider the nature of the chemical system when investigating entanglement phenomena in the framework of Gaussian type basis sets: while in case of hydride the use of augmentation functions is crucial, the application of core functions greatly improves the accuracy in case of cationic systems such as Li(+) and Be(2+). In addition, numerical derivatives of the entanglement measures with respect to the nucleic charge have been determined, which proved to be a very sensitive probe of the convergence leading to qualitatively wrong results (i.e., the wrong sign) if too small basis sets are used.
Intraoral distalizer effects with conventional and skeletal anchorage: a meta-analysis.
Grec, Roberto Henrique da Costa; Janson, Guilherme; Branco, Nuria Castello; Moura-Grec, Patrícia Garcia; Patel, Mayara Paim; Castanha Henriques, José Fernando
2013-05-01
The aims of this meta-analysis were to quantify and to compare the amounts of distalization and anchorage loss of conventional and skeletal anchorage methods in the correction of Class II malocclusion with intraoral distalizers. The literature was searched through 5 electronic databases, and inclusion criteria were applied. Articles that presented pretreatment and posttreatment cephalometric values were preferred. Quality assessments of the studies were performed. The averages and standard deviations of molar and premolar effects were extracted from the studies to perform a meta-analysis. After applying the inclusion and exclusion criteria, 40 studies were included in the systematic review. After the quality analysis, 2 articles were classified as high quality, 27 as medium quality, and 11 as low quality. For the meta-analysis, 6 studies were included, and they showed average molar distalization amounts of 3.34 mm with conventional anchorage and 5.10 mm with skeletal anchorage. The meta-analysis of premolar movement showed estimates of combined effects of 2.30 mm (mesialization) in studies with conventional anchorage and -4.01 mm (distalization) in studies with skeletal anchorage. There was scientific evidence that both anchorage systems are effective for distalization; however, with skeletal anchorage, there was no anchorage loss when direct anchorage was used. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics
Rist, Manuela J.; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard
2013-01-01
It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at −20 °C, on dry ice, at −80 °C or in liquid nitrogen and then stored at −20 °C, −80 °C or in liquid nitrogen vapor phase for 1–5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at −20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol. PMID:24957990
Influence of Freezing and Storage Procedure on Human Urine Samples in NMR-Based Metabolomics.
Rist, Manuela J; Muhle-Goll, Claudia; Görling, Benjamin; Bub, Achim; Heissler, Stefan; Watzl, Bernhard; Luy, Burkhard
2013-04-09
It is consensus in the metabolomics community that standardized protocols should be followed for sample handling, storage and analysis, as it is of utmost importance to maintain constant measurement conditions to identify subtle biological differences. The aim of this work, therefore, was to systematically investigate the influence of freezing procedures and storage temperatures and their effect on NMR spectra as a potentially disturbing aspect for NMR-based metabolomics studies. Urine samples were collected from two healthy volunteers, centrifuged and divided into aliquots. Urine aliquots were frozen either at -20 °C, on dry ice, at -80 °C or in liquid nitrogen and then stored at -20 °C, -80 °C or in liquid nitrogen vapor phase for 1-5 weeks before NMR analysis. Results show spectral changes depending on the freezing procedure, with samples frozen on dry ice showing the largest deviations. The effect was found to be based on pH differences, which were caused by variations in CO2 concentrations introduced by the freezing procedure. Thus, we recommend that urine samples should be frozen at -20 °C and transferred to lower storage temperatures within one week and that freezing procedures should be part of the publication protocol.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grantham, K; Santanam, L; Goddu, S
Purpose: We retrospectively evaluate the dosimetric impact of a 3.5% range uncertainty on CTV coverage and normal organ toxicity for a cohort of brain patients. Methods: Twenty treatment plans involving 20 brain cancer patients treated with Mevions S250 were reviewed. Forty uncertain plans were made by changing the ranges in original plans by ±3.5% while keeping all devices unchanged. Fidelity to the original plans was evaluated with gamma index. Changes in generalized equivalent uniform dose (gEUD) were reported for the following structures: CTV coverage, brainstem, optic chiasm, and optic nerves. Comparisons were made by plotting the relevant endpoints from themore » uncertain plans as a function of the same endpoints from the original clinical plan. Results: Gamma-index analysis resulted in a 50% pass rate of the uncertain plans using a 90% passing rate and 3%/3mm criterion. A 9.5% decrease in the slope of gEUD plot for the CTV was observed for the 3.5% downward range shift. However, the change in slope did not result in a gEUD change greater than 1.1% for the CTV. The slopes of the gEUD plots for normal structures increased by 3.1% 3.9% 2.4% and 0.2% for the chiasm, brainstem, left optic nerve and right optic nerve respectively. The maximum deviation from the gEUD of the clinical plan for normal structures was: 64% in the chiasm, 31% for the brainstem, and 19% for both optic nerves. Conclusion: A retrospective review shows moderate radiobiological impact of range uncertainty in passively scattered proton therapy with sporadic catastrophe. The linear regression analysis on the statistical data indicates a systematic deviation of gEUD from treatment planning in the light of range uncertainty.« less
The midnight density maximum in the S. Marco V and the S. Marco III equatorial density data sets
NASA Astrophysics Data System (ADS)
Arduini, C.; Laneve, G.; Ponzi, U.
In a previous paper we showed some systematic deviations of the S. Marco V drag balance equatorial density data with respect to the MSIS86 model. We interpreted these deviations as due, at least in part, to the presence of a variable ``Midnight Density Maximum'' (MDM). In the data, there was in fact evidence of some altitude and seasonal variation of this pattern. In the present paper we consider, besides the S. Marco V data base (density measured during 1988), the S. Marco III data base, collected in 1971 almost in the same seasonal period and altitude range, with an instrument very similar to that of the S. Marco V. The use of both data sets is allowing a rather detailed description of the phenomenon as seen by the DBI instrument, for what concerns both the ``seasonal'' and altitude variations. In addition also some longitude effects are evidenced, for instance, by the MITS and QUITO data subsets of S. Marco III, taken respectively around 40 deg and 280 deg East longitude. Notice in addition that S. M. III data refer to the year 1971 (descending part of solar cycle 20) while SMV was launched in 1988 (ascending part of solar cycle 22); the comparison is thus allowing to evidence the persistence of the phenomenon and of its main characteristics. The observed data are consistent ``at large'' for both S. Marco III and V, while the differences in the details are providing hints on the mechanisms of the thermospheric dynamics (tidal theory and neutral-charged interactions). The paper presents the above said features together with a discussion on the characteristics of the two data bases and on their possible relevance for modeling the considered MDM feature.
Effects of visual information regarding allocentric processing in haptic parallelity matching.
Van Mier, Hanneke I
2013-10-01
Research has revealed that haptic perception of parallelity deviates from physical reality. Large and systematic deviations have been found in haptic parallelity matching most likely due to the influence of the hand-centered egocentric reference frame. Providing information that increases the influence of allocentric processing has been shown to improve performance on haptic matching. In this study allocentric processing was stimulated by providing informative vision in haptic matching tasks that were performed using hand- and arm-centered reference frames. Twenty blindfolded participants (ten men, ten women) explored the orientation of a reference bar with the non-dominant hand and subsequently matched (task HP) or mirrored (task HM) its orientation on a test bar with the dominant hand. Visual information was provided by means of informative vision with participants having full view of the test bar, while the reference bar was blocked from their view (task VHP). To decrease the egocentric bias of the hands, participants also performed a visual haptic parallelity drawing task (task VHPD) using an arm-centered reference frame, by drawing the orientation of the reference bar. In all tasks, the distance between and orientation of the bars were manipulated. A significant effect of task was found; performance improved from task HP, to VHP to VHPD, and HM. Significant effects of distance were found in the first three tasks, whereas orientation and gender effects were only significant in tasks HP and VHP. The results showed that stimulating allocentric processing by means of informative vision and reducing the egocentric bias by using an arm-centered reference frame led to most accurate performance on parallelity matching. © 2013 Elsevier B.V. All rights reserved.
Fitting the constitution type Ia supernova data with the redshift-binned parametrization method
NASA Astrophysics Data System (ADS)
Huang, Qing-Guo; Li, Miao; Li, Xiao-Dong; Wang, Shuang
2009-10-01
In this work, we explore the cosmological consequences of the recently released Constitution sample of 397 Type Ia supernovae (SNIa). By revisiting the Chevallier-Polarski-Linder (CPL) parametrization, we find that, for fitting the Constitution set alone, the behavior of dark energy (DE) significantly deviates from the cosmological constant Λ, where the equation of state (EOS) w and the energy density ρΛ of DE will rapidly decrease along with the increase of redshift z. Inspired by this clue, we separate the redshifts into different bins, and discuss the models of a constant w or a constant ρΛ in each bin, respectively. It is found that for fitting the Constitution set alone, w and ρΛ will also rapidly decrease along with the increase of z, which is consistent with the result of CPL model. Moreover, a step function model in which ρΛ rapidly decreases at redshift z˜0.331 presents a significant improvement (Δχ2=-4.361) over the CPL parametrization, and performs better than other DE models. We also plot the error bars of DE density of this model, and find that this model deviates from the cosmological constant Λ at 68.3% confidence level (CL); this may arise from some biasing systematic errors in the handling of SNIa data, or more interestingly from the nature of DE itself. In addition, for models with same number of redshift bins, a piecewise constant ρΛ model always performs better than a piecewise constant w model; this shows the advantage of using ρΛ, instead of w, to probe the variation of DE.
A disc corona-jet model for the radio/X-ray correlation in black hole X-ray binaries
NASA Astrophysics Data System (ADS)
Qiao, Erlin; Liu, B. F.
2015-04-01
The observed tight radio/X-ray correlation in the low spectral state of some black hole X-ray binaries implies the strong coupling of the accretion and jet. The correlation of L_R ∝ L_X^{˜ 0.5-0.7} was well explained by the coupling of a radiatively inefficient accretion flow and a jet. Recently, however, a growing number of sources show more complicated radio/X-ray correlations, e.g. L_R ∝ L_X^{˜ 1.4} for LX/LEdd ≳ 10-3, which is suggested to be explained by the coupling of a radiatively efficient accretion flow and a jet. In this work, we interpret the deviation from the initial radio/X-ray correlation for LX/LEdd ≳ 10-3 with a detailed disc corona-jet model. In this model, the disc and corona are radiatively and dynamically coupled. Assuming a fraction of the matter in the accretion flow, η ≡ dot{M}_jet/dot{M}, is ejected to form the jet, we can calculate the emergent spectrum of the disc corona-jet system. We calculate LR and LX at different dot{M}, adjusting η to fit the observed radio/X-ray correlation of the black hole X-ray transient H1743-322 for LX/LEdd > 10-3. It is found that always the X-ray emission is dominated by the disc corona and the radio emission is dominated by the jet. We noted that the value of η for the deviated radio/X-ray correlation for LX/LEdd > 10-3 is systematically less than that of the case for LX/LEdd < 10-3, which is consistent with the general idea that the jet is often relatively suppressed at the high-luminosity phase in black hole X-ray binaries.
Habes, M; Janowitz, D; Erus, G; Toledo, J B; Resnick, S M; Doshi, J; Van der Auwera, S; Wittfeld, K; Hegenscheid, K; Hosten, N; Biffar, R; Homuth, G; Völzke, H; Grabe, H J; Hoffmann, W; Davatzikos, C
2016-04-05
We systematically compared structural imaging patterns of advanced brain aging (ABA) in the general-population, herein defined as significant deviation from typical BA to those found in Alzheimer disease (AD). The hypothesis that ABA would show different patterns of structural change compared with those found in AD was tested via advanced pattern analysis methods. In particular, magnetic resonance images of 2705 participants from the Study of Health in Pomerania (aged 20-90 years) were analyzed using an index that captures aging atrophy patterns (Spatial Pattern of Atrophy for Recognition of BA (SPARE-BA)), and an index previously shown to capture atrophy patterns found in clinical AD (Spatial Patterns of Abnormality for Recognition of Early Alzheimer's Disease (SPARE-AD)). We studied the association between these indices and risk factors, including an AD polygenic risk score. Finally, we compared the ABA-associated atrophy with typical AD-like patterns. We observed that SPARE-BA had significant association with: smoking (P<0.05), anti-hypertensive (P<0.05), anti-diabetic drug use (men P<0.05, women P=0.06) and waist circumference for the male cohort (P<0.05), after adjusting for age. Subjects with ABA had spatially extensive gray matter loss in the frontal, parietal and temporal lobes (false-discovery-rate-corrected q<0.001). ABA patterns of atrophy were partially overlapping with, but notably deviating from those typically found in AD. Subjects with ABA had higher SPARE-AD values; largely due to the partial spatial overlap of associated patterns in temporal regions. The AD polygenic risk score was significantly associated with SPARE-AD but not with SPARE-BA. Our findings suggest that ABA is likely characterized by pathophysiologic mechanisms that are distinct from, or only partially overlapping with those of AD.
Assessment of Stable Isotope Distribution in Complex Systems
NASA Astrophysics Data System (ADS)
He, Y.; Cao, X.; Wang, J.; Bao, H.
2017-12-01
Biomolecules in living organisms have the potential to approach chemical steady state and even apparent isotope equilibrium because enzymatic reactions are intrinsically reversible. If an apparent local equilibrium can be identified, enzymatic reversibility and its controlling factors may be quantified, which helps to understand complex biochemical processes. Earlier research on isotope fractionation tends to focus on specific process and compare mostly two different chemical species. Using linear regression, "Thermodynamic order", which refers to correlated δ13C and 13β values, has been proposed to be present among many biomolecules by Galimov et al. However, the concept "thermodynamic order" they proposed and the approach they used has been questioned. Here, we propose that the deviation of a complex system from its equilibrium state can be rigorously described as a graph problem as is applied in discrete mathematics. The deviation of isotope distribution from equilibrium state and apparent local isotope equilibrium among a subset of biomolecules can be assessed using an apparent fractionation difference matrix (|Δα|). Applying the |Δα| matrix analysis to earlier published data of amino acids, we show the existence of apparent local equilibrium among different amino acids in potato and a kind of green alga. The existence of apparent local equilibrium is in turn consistent with the notion that enzymatic reactions can be reversible even in living systems. The result also implies that previous emphasis on external carbon source intake may be misplaced when studying isotope distribution in physiology. In addition to the identification of local equilibrium among biomolecules, the difference matrix approach has the potential to explore chemical or isotope equilibrium state in extraterrestrial bodies, to distinguish living from non-living systems, and to classify living species. This approach will benefit from large numbers of systematic data and advanced pattern recognition techniques.
Systematic variation of rare earths in monazite
Murata, K.J.; Rose, H.J.; Carron, M.K.
1953-01-01
Ten monazites from widely scattered localities have been analyzed for La, Ce, Pr, Nd, Sm, Gd, Y and Th by means of a combined chemical and emission spectrographic method. The analytical results, calculated to atomic percent of total rare earths (thorium excluded), show a considerable variation in the proportions of every element except praseodymium, which is relatively constant. The general variation trends of the elements may be calculated by assuming that the monazites represent different stages in a fractional precipitation process, and by assuming that there is a gradational increase in the precipitability of rare earth elements with decreasing ionic radius. Fractional precipitation brings about an increase in lanthanum and cerium, little change in praseodymium, and a decrease in neodymium, samarium, gadolinium, and yttrium. Deviations from the calculated lines of variation consist of a simultaneous, abnormal increase or decrease in the proportions of cerium, praseodymium, and neodymium with antipathetic decrease or increase in the proportions of the other elements. These deviations are ascribed to abnormally high or low temperatures that affect the precipitability of the central trio of elements (Ce, Pr, Nd) relatively more than that of the other elements. The following semiquantitative rules have been found useful in describing the composition of rare earths from monazite: 1. 1. The sum of lanthanum and neodymium is very nearly a constant at 42 ?? 2 atomic percent. 2. 2. Praseodymium is very nearly constant at 5 ?? 1 atomic percent. 3. 3. The sum of Ce, Sm, Gd, and Y is very nearly a constant at 53 ?? 3 atomic percent. No correlation could be established between the content of Th and that of any of the rare earth elements. ?? 1953.
Ardekani, Siamak; Selva, Luis; Sayre, James; Sinha, Usha
2006-11-01
Single-shot echo-planar based diffusion tensor imaging is prone to geometric and intensity distortions. Parallel imaging is a means of reducing these distortions while preserving spatial resolution. A quantitative comparison at 3 T of parallel imaging for diffusion tensor images (DTI) using k-space (generalized auto-calibrating partially parallel acquisitions; GRAPPA) and image domain (sensitivity encoding; SENSE) reconstructions at different acceleration factors, R, is reported here. Images were evaluated using 8 human subjects with repeated scans for 2 subjects to estimate reproducibility. Mutual information (MI) was used to assess the global changes in geometric distortions. The effects of parallel imaging techniques on random noise and reconstruction artifacts were evaluated by placing 26 regions of interest and computing the standard deviation of apparent diffusion coefficient and fractional anisotropy along with the error of fitting the data to the diffusion model (residual error). The larger positive values in mutual information index with increasing R values confirmed the anticipated decrease in distortions. Further, the MI index of GRAPPA sequences for a given R factor was larger than the corresponding mSENSE images. The residual error was lowest in the images acquired without parallel imaging and among the parallel reconstruction methods, the R = 2 acquisitions had the least error. The standard deviation, accuracy, and reproducibility of the apparent diffusion coefficient and fractional anisotropy in homogenous tissue regions showed that GRAPPA acquired with R = 2 had the least amount of systematic and random noise and of these, significant differences with mSENSE, R = 2 were found only for the fractional anisotropy index. Evaluation of the current implementation of parallel reconstruction algorithms identified GRAPPA acquired with R = 2 as optimal for diffusion tensor imaging.
Zgarbová, Marie; Otyepka, Michal; Sponer, Jirí; Hobza, Pavel; Jurecka, Petr
2010-09-21
The intermolecular interaction energy components for several molecular complexes were calculated using force fields available in the AMBER suite of programs and compared with Density Functional Theory-Symmetry Adapted Perturbation Theory (DFT-SAPT) values. The extent to which such comparison is meaningful is discussed. The comparability is shown to depend strongly on the intermolecular distance, which means that comparisons made at one distance only are of limited value. At large distances the coulombic and van der Waals 1/r(6) empirical terms correspond fairly well with the DFT-SAPT electrostatics and dispersion terms, respectively. At the onset of electronic overlap the empirical values deviate from the reference values considerably. However, the errors in the force fields tend to cancel out in a systematic manner at equilibrium distances. Thus, the overall performance of the force fields displays errors an order of magnitude smaller than those of the individual interaction energy components. The repulsive 1/r(12) component of the van der Waals expression seems to be responsible for a significant part of the deviation of the force field results from the reference values. We suggest that further improvement of the force fields for intermolecular interactions would require replacement of the nonphysical 1/r(12) term by an exponential function. Dispersion anisotropy and its effects are discussed. Our analysis is intended to show that although comparing the empirical and non-empirical interaction energy components is in general problematic, it might bring insights useful for the construction of new force fields. Our results are relevant to often performed force-field-based interaction energy decompositions.
Fitting the constitution type Ia supernova data with the redshift-binned parametrization method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang Qingguo; Kavli Institute for Theoretical Physics China, Chinese Academy of Sciences, Beijing 100190; Li Miao
2009-10-15
In this work, we explore the cosmological consequences of the recently released Constitution sample of 397 Type Ia supernovae (SNIa). By revisiting the Chevallier-Polarski-Linder (CPL) parametrization, we find that, for fitting the Constitution set alone, the behavior of dark energy (DE) significantly deviates from the cosmological constant {lambda}, where the equation of state (EOS) w and the energy density {rho}{sub {lambda}} of DE will rapidly decrease along with the increase of redshift z. Inspired by this clue, we separate the redshifts into different bins, and discuss the models of a constant w or a constant {rho}{sub {lambda}} in each bin,more » respectively. It is found that for fitting the Constitution set alone, w and {rho}{sub {lambda}} will also rapidly decrease along with the increase of z, which is consistent with the result of CPL model. Moreover, a step function model in which {rho}{sub {lambda}} rapidly decreases at redshift z{approx}0.331 presents a significant improvement ({delta}{chi}{sup 2}=-4.361) over the CPL parametrization, and performs better than other DE models. We also plot the error bars of DE density of this model, and find that this model deviates from the cosmological constant {lambda} at 68.3% confidence level (CL); this may arise from some biasing systematic errors in the handling of SNIa data, or more interestingly from the nature of DE itself. In addition, for models with same number of redshift bins, a piecewise constant {rho}{sub {lambda}} model always performs better than a piecewise constant w model; this shows the advantage of using {rho}{sub {lambda}}, instead of w, to probe the variation of DE.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, J.; Cameron, R. H.; Schüssler, M., E-mail: jiejiang@nao.cas.cn
The tilt angles of sunspot groups represent the poloidal field source in Babcock-Leighton-type models of the solar dynamo and are crucial for the build-up and reversals of the polar fields in surface flux transport (SFT) simulations. The evolution of the polar field is a consequence of Hale's polarity rules, together with the tilt angle distribution which has a systematic component (Joy's law) and a random component (tilt-angle scatter). We determine the scatter using the observed tilt angle data and study the effects of this scatter on the evolution of the solar surface field using SFT simulations with flux input basedmore » upon the recorded sunspot groups. The tilt angle scatter is described in our simulations by a random component according to the observed distributions for different ranges of sunspot group size (total umbral area). By performing simulations with a number of different realizations of the scatter we study the effect of the tilt angle scatter on the global magnetic field, especially on the evolution of the axial dipole moment. The average axial dipole moment at the end of cycle 17 (a medium-amplitude cycle) from our simulations was 2.73 G. The tilt angle scatter leads to an uncertainty of 0.78 G (standard deviation). We also considered cycle 14 (a weak cycle) and cycle 19 (a strong cycle) and show that the standard deviation of the axial dipole moment is similar for all three cycles. The uncertainty mainly results from the big sunspot groups which emerge near the equator. In the framework of Babcock-Leighton dynamo models, the tilt angle scatter therefore constitutes a significant random factor in the cycle-to-cycle amplitude variability, which strongly limits the predictability of solar activity.« less
Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo A; Sánchez-Labraca, Nuria; Quesada-Rubio, José Manuel; Granero-Molina, José; Moreno-Lorenzo, Carmen
2011-01-01
Fibromyalgia is a prevalent musculoskeletal disorder associated with widespread mechanical tenderness, fatigue, non-refreshing sleep, depressed mood and pervasive dysfunction of the autonomic nervous system: tachycardia, postural intolerance, Raynaud's phenomenon and diarrhoea. To determine the effects of craniosacral therapy on sensitive tender points and heart rate variability in patients with fibromyalgia. A randomized controlled trial. Ninety-two patients with fibromyalgia were randomly assigned to an intervention group or placebo group. Patients received treatments for 20 weeks. The intervention group underwent a craniosacral therapy protocol and the placebo group received sham treatment with disconnected magnetotherapy equipment. Pain intensity levels were determined by evaluating tender points, and heart rate variability was recorded by 24-hour Holter monitoring. After 20 weeks of treatment, the intervention group showed significant reduction in pain at 13 of the 18 tender points (P < 0.05). Significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement versus baseline values were observed in the intervention group but not in the placebo group. At two months and one year post therapy, the intervention group showed significant differences versus baseline in tender points at left occiput, left-side lower cervical, left epicondyle and left greater trochanter and significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement. Craniosacral therapy improved medium-term pain symptoms in patients with fibromyalgia.
Testing the equivalence principle on cosmological scales
NASA Astrophysics Data System (ADS)
Bonvin, Camille; Fleury, Pierre
2018-05-01
The equivalence principle, that is one of the main pillars of general relativity, is very well tested in the Solar system; however, its validity is more uncertain on cosmological scales, or when dark matter is concerned. This article shows that relativistic effects in the large-scale structure can be used to directly test whether dark matter satisfies Euler's equation, i.e. whether its free fall is characterised by geodesic motion, just like baryons and light. After having proposed a general parametrisation for deviations from Euler's equation, we perform Fisher-matrix forecasts for future surveys like DESI and the SKA, and show that such deviations can be constrained with a precision of order 10%. Deviations from Euler's equation cannot be tested directly with standard methods like redshift-space distortions and gravitational lensing, since these observables are not sensitive to the time component of the metric. Our analysis shows therefore that relativistic effects bring new and complementary constraints to alternative theories of gravity.
Pagel, Tobias; Franklin, Jeremy; Baethge, Christopher
2014-03-01
Schizoaffective disorder is viewed as a heterogeneous diagnosis among psychotic illnesses. Different diagnostic systems differ in their definition with DSM (-IIIR, -IV, and -V) providing a narrower definition than RDC and ICD-10. It is unclear whether this difference is reflected in patient samples diagnosed according to different diagnostic systems. Exploratory study based on a systematic review of studies of schizoaffective disorder samples diagnosed by either RDC and ICD-10 (group of "broad criteria") or DSM-IIIR and -IV ("narrow criteria"); comparison (by Mann-Whitney-U-tests) of key characteristics, such as age, number of hospitalizations, or scores in psychometric tests, between more broadly and more narrowly defined schizoaffective disorder samples using standard deviations as a measurement of heterogeneity as well as weighted means and percentages. To reduce selection bias only studies including schizoaffective patient samples together with affective disorder and schizophrenia samples were selected. 55 studies were included, 14 employing RDC, 4 ICD-10, 20 DSM-IIIR, and 17 DSM-IV. Thirteen characteristics were compared: patients diagnosed according to broader criteria had fewer previous hospitalizations (2.2 vs. 5.4) and were both less often male (42 vs. 51%) and married (21 vs. 40%). Heterogeneity was similar in both groups but slightly higher in RDC and ICD-10 samples than in DSM-IIIR and -IV-samples: +4% regarding demographic and clinical course data and +13% regarding psychometric tests (pooled SD). Secular trends and different designs may have confounded the results and limit generalizability. Some comparisons were underpowered. Differences in diagnostic criteria are reflected in key characteristics of samples. The association of larger heterogeneity with wider diagnostic criteria supports employing standard deviations as a measurement of heterogeneity. Copyright © 2013 Elsevier B.V. All rights reserved.
Influence of Systematic Increases in Treadmill Walking Speed on Gait Kinematics After Stroke
Tyrell, Christine M.; Roos, Margaret A.; Rudolph, Katherine S.
2011-01-01
Background Fast treadmill training improves walking speed to a greater extent than training at a self-selected speed after stroke. It is unclear whether fast treadmill walking facilitates a more normal gait pattern after stroke, as has been suggested for treadmill training at self-selected speeds. Given the massed stepping practice that occurs during treadmill training, it is important for therapists to understand how the treadmill speed selected influences the gait pattern that is practiced on the treadmill. Objective The purpose of this study was to characterize the effect of systematic increases in treadmill speed on common gait deviations observed after stroke. Design A repeated-measures design was used. Methods Twenty patients with stroke walked on a treadmill at their self-selected walking speed, their fastest speed, and 2 speeds in between. Using a motion capture system, spatiotemporal gait parameters and kinematic gait compensations were measured. Results Significant improvements in paretic- and nonparetic-limb step length and in single- and double-limb support were found. Asymmetry of these measures improved only for step length. Significant improvements in paretic hip extension, trailing limb position, and knee flexion during swing also were found as speed increased. No increases in circumduction or hip hiking were found with increasing speed. Limitations Caution should be used when generalizing these results to survivors of a stroke with a self-selected walking speed of less than 0.4 m/s. This study did not address changes with speed during overground walking. Conclusions Faster treadmill walking facilitates a more normal walking pattern after stroke, without concomitant increases in common gait compensations, such as circumduction. The improvements in gait deviations were observed with small increases in walking speed. PMID:21252308
NASA Astrophysics Data System (ADS)
Lees, J. P.; Poireau, V.; Tisserand, V.; Garra Tico, J.; Grauges, E.; Palano, A.; Eigen, G.; Stugu, B.; Brown, D. N.; Kerth, L. T.; Kolomensky, Yu. G.; Lynch, G.; Koch, H.; Schroeder, T.; Asgeirsson, D. J.; Hearty, C.; Mattison, T. S.; McKenna, J. A.; So, R. Y.; Khan, A.; Blinov, V. E.; Buzykaev, A. R.; Druzhinin, V. P.; Golubev, V. B.; Kravchenko, E. A.; Onuchin, A. P.; Serednyakov, S. I.; Skovpen, Yu. I.; Solodov, E. P.; Todyshev, K. Yu.; Yushkov, A. N.; Bondioli, M.; Kirkby, D.; Lankford, A. J.; Mandelkern, M.; Atmacan, H.; Gary, J. W.; Liu, F.; Long, O.; Vitug, G. M.; Campagnari, C.; Hong, T. M.; Kovalskyi, D.; Richman, J. D.; West, C. A.; Eisner, A. M.; Kroseberg, J.; Lockman, W. S.; Martinez, A. J.; Schumm, B. A.; Seiden, A.; Chao, D. S.; Cheng, C. H.; Echenard, B.; Flood, K. T.; Hitlin, D. G.; Ongmongkolkul, P.; Porter, F. C.; Rakitin, A. Y.; Andreassen, R.; Huard, Z.; Meadows, B. T.; Sokoloff, M. D.; Sun, L.; Bloom, P. C.; Ford, W. T.; Gaz, A.; Nauenberg, U.; Smith, J. G.; Wagner, S. R.; Ayad, R.; Toki, W. H.; Spaan, B.; Schubert, K. R.; Schwierz, R.; Bernard, D.; Verderi, M.; Clark, P. J.; Playfer, S.; Bettoni, D.; Bozzi, C.; Calabrese, R.; Cibinetto, G.; Fioravanti, E.; Garzia, I.; Luppi, E.; Munerato, M.; Negrini, M.; Piemontese, L.; Santoro, V.; Baldini-Ferroli, R.; Calcaterra, A.; de Sangro, R.; Finocchiaro, G.; Patteri, P.; Peruzzi, I. M.; Piccolo, M.; Rama, M.; Zallo, A.; Contri, R.; Guido, E.; Lo Vetere, M.; Monge, M. R.; Passaggio, S.; Patrignani, C.; Robutti, E.; Bhuyan, B.; Prasad, V.; Lee, C. L.; Morii, M.; Edwards, A. J.; Adametz, A.; Uwer, U.; Lacker, H. M.; Lueck, T.; Dauncey, P. D.; Behera, P. K.; Mallik, U.; Chen, C.; Cochran, J.; Meyer, W. T.; Prell, S.; Rubin, A. E.; Gritsan, A. V.; Guo, Z. J.; Arnaud, N.; Davier, M.; Derkach, D.; Grosdidier, G.; Le Diberder, F.; Lutz, A. M.; Malaescu, B.; Roudeau, P.; Schune, M. H.; Stocchi, A.; Wormser, G.; Lange, D. J.; Wright, D. M.; Chavez, C. A.; Coleman, J. P.; Fry, J. R.; Gabathuler, E.; Hutchcroft, D. E.; Payne, D. J.; Touramanis, C.; Bevan, A. J.; Di Lodovico, F.; Sacco, R.; Sigamani, M.; Cowan, G.; Brown, D. N.; Davis, C. L.; Denig, A. G.; Fritsch, M.; Gradl, W.; Griessinger, K.; Hafner, A.; Prencipe, E.; Barlow, R. J.; Jackson, G.; Lafferty, G. D.; Behn, E.; Cenci, R.; Hamilton, B.; Jawahery, A.; Roberts, D. A.; Dallapiccola, C.; Cowan, R.; Dujmic, D.; Sciolla, G.; Cheaib, R.; Lindemann, D.; Patel, P. M.; Robertson, S. H.; Biassoni, P.; Neri, N.; Palombo, F.; Stracka, S.; Cremaldi, L.; Godang, R.; Kroeger, R.; Sonnek, P.; Summers, D. J.; Nguyen, X.; Simard, M.; Taras, P.; De Nardo, G.; Monorchio, D.; Onorato, G.; Sciacca, C.; Martinelli, M.; Raven, G.; Jessop, C. P.; LoSecco, J. M.; Wang, W. F.; Honscheid, K.; Kass, R.; Brau, J.; Frey, R.; Sinev, N. B.; Strom, D.; Torrence, E.; Feltresi, E.; Gagliardi, N.; Margoni, M.; Morandin, M.; Posocco, M.; Rotondo, M.; Simi, G.; Simonetto, F.; Stroili, R.; Akar, S.; Ben-Haim, E.; Bomben, M.; Bonneaud, G. R.; Briand, H.; Calderini, G.; Chauveau, J.; Hamon, O.; Leruste, Ph.; Marchiori, G.; Ocariz, J.; Sitt, S.; Biasini, M.; Manoni, E.; Pacetti, S.; Rossi, A.; Angelini, C.; Batignani, G.; Bettarini, S.; Carpinelli, M.; Casarosa, G.; Cervelli, A.; Forti, F.; Giorgi, M. A.; Lusiani, A.; Oberhof, B.; Paoloni, E.; Perez, A.; Rizzo, G.; Walsh, J. J.; Lopes Pegna, D.; Olsen, J.; Smith, A. J. S.; Telnov, A. V.; Anulli, F.; Faccini, R.; Ferrarotto, F.; Ferroni, F.; Gaspero, M.; Li Gioi, L.; Mazzoni, M. A.; Piredda, G.; Bünger, C.; Grünberg, O.; Hartmann, T.; Leddig, T.; Schröder, H.; Voss, C.; Waldi, R.; Adye, T.; Olaiya, E. O.; Wilson, F. F.; Emery, S.; Hamel de Monchenault, G.; Vasseur, G.; Yèche, Ch.; Aston, D.; Bard, D. J.; Bartoldus, R.; Benitez, J. F.; Cartaro, C.; Convery, M. R.; Dorfan, J.; Dubois-Felsmann, G. P.; Dunwoodie, W.; Ebert, M.; Field, R. C.; Franco Sevilla, M.; Fulsom, B. G.; Gabareen, A. M.; Graham, M. T.; Grenier, P.; Hast, C.; Innes, W. R.; Kelsey, M. H.; Kim, P.; Kocian, M. L.; Leith, D. W. G. S.; Lewis, P.; Lindquist, B.; Luitz, S.; Luth, V.; Lynch, H. L.; MacFarlane, D. B.; Muller, D. R.; Neal, H.; Nelson, S.; Perl, M.; Pulliam, T.; Ratcliff, B. N.; Roodman, A.; Salnikov, A. A.; Schindler, R. H.; Snyder, A.; Su, D.; Sullivan, M. K.; Va'vra, J.; Wagner, A. P.; Wisniewski, W. J.; Wittgen, M.; Wright, D. H.; Wulsin, H. W.; Young, C. C.; Ziegler, V.; Park, W.; Purohit, M. V.; White, R. M.; Wilson, J. R.; Randle-Conde, A.; Sekula, S. J.; Bellis, M.; Burchat, P. R.; Miyashita, T. S.; Alam, M. S.; Ernst, J. A.; Gorodeisky, R.; Guttman, N.; Peimer, D. R.; Soffer, A.; Lund, P.; Spanier, S. M.; Ritchie, J. L.; Ruland, A. M.; Schwitters, R. F.; Wray, B. C.; Izen, J. M.; Lou, X. C.; Bianchi, F.; Gamba, D.; Lanceri, L.; Vitale, L.; Martinez-Vidal, F.; Oyanguren, A.; Ahmed, H.; Albert, J.; Banerjee, Sw.; Bernlochner, F. U.; Choi, H. H. F.; King, G. J.; Kowalewski, R.; Lewczuk, M. J.; Nugent, I. M.; Roney, J. M.; Sobie, R. J.; Tasneem, N.; Gershon, T. J.; Harrison, P. F.; Latham, T. E.; Puccio, E. M. T.; Band, H. R.; Dasu, S.; Pan, Y.; Prepost, R.; Wu, S. L.
2013-03-01
We present improved measurements of CP-violation parameters in the decays B0→π+π-, B0→K+π-, and B0→π0π0, and of the branching fractions for B0→π0π0 and B0→K0π0. The results are obtained with the full data set collected at the Υ(4S) resonance by the BABAR experiment at the PEP-II asymmetric-energy B factory at the SLAC National Accelerator Laboratory, corresponding to (467±5)×106 BB¯ pairs. We find the CP-violation parameter values and branching fractions: Sπ+π-=-0.68±0.10±0.03, Cπ+π-=-0.25±0.08±0.02, AK-π+=-0.107±0.016-0.004+0.006, Cπ0π0=-0.43±0.26±0.05, B(B0→π0π0)=(1.83±0.21±0.13)×10-6, B(B0→K0π0)=(10.1±0.6±0.4)×10-6, where in each case, the first uncertainties are statistical and the second are systematic. We observe CP violation with a significance of 6.7 standard deviations for B0→π+π- and 6.1 standard deviations for B0→K+π-, including systematic uncertainties. Constraints on the unitarity triangle angle α are determined from the isospin relations among the B→ππ rates and asymmetries. Considering only the solution preferred by the Standard Model, we find α to be in the range [71°,109°] at the 68% confidence level.
Baek, Chaehwan; Paeng, Jun-Young; Lee, Janice S; Hong, Jongrak
2012-05-01
A systematic classification is needed for the diagnosis and surgical treatment of facial asymmetry. The purposes of this study were to analyze the skeletal structures of patients with facial asymmetry and to objectively classify these patients into groups according to these structural characteristics. Patients with facial asymmetry and recent computed tomographic images from 2005 through 2009 were included in this study, which was approved by the institutional review board. Linear measurements, angles, and reference planes on 3-dimensional computed tomograms were obtained, including maxillary (upper midline deviation, maxilla canting, and arch form discrepancy) and mandibular (menton deviation, gonion to midsagittal plane, ramus height, and frontal ramus inclination) measurements. All measurements were analyzed using paired t tests with Bonferroni correction followed by K-means cluster analysis using SPSS 13.0 to determine an objective classification of facial asymmetry in the enrolled patients. Kruskal-Wallis test was performed to verify differences among clustered groups. P < .05 was considered statistically significant. Forty-three patients (18 male, 25 female) were included in the study. They were classified into 4 groups based on cluster analysis. Their mean age was 24.3 ± 4.4 years. Group 1 included subjects (44% of patients) with asymmetry caused by a shift or lateralization of the mandibular body. Group 2 included subjects (39%) with a significant difference between the left and right ramus height with menton deviation to the short side. Group 3 included subjects (12%) with atypical asymmetry, including deviation of the menton to the short side, prominence of the angle/gonion on the larger side, and reverse maxillary canting. Group 4 included subjects (5%) with severe maxillary canting, ramus height differences, and menton deviation to the short side. In this study, patients with asymmetry were classified into 4 statistically distinct groups according to their anatomic features. This diagnostic classification method will assist in treatment planning for patients with facial asymmetry and may be used to explore the etiology of these variants of facial asymmetry. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Reciprocity in the electronic stopping of slow ions in matter
NASA Astrophysics Data System (ADS)
Sigmund, P.
2008-04-01
The principle of reciprocity, i.e., the invariance of the inelastic excitation in ion-atom collisions against interchange of projectile and target, has been applied to the electronic stopping cross section of low-velocity ions and tested empirically on ion-target combinations supported by a more or less adequate amount of experimental data. Reciprocity is well obeyed (within ~10%) for many systems studied, and deviations exceeding ~20% are exceptional. Systematic deviations such as gas-solid or metal-insulator differences have been looked for but not identified on the present basis. A direct consequence of reciprocity is the equivalence of Z1 with Z2 structure for random slowing down. This feature is reasonably well supported empirically for ion-target combinations involving carbon, nitrogen, aluminium and argon. Reciprocity may be utilized as a criterion to reject questionable experimental data. In cases where a certain stopping cross section has not been or cannot be measured, the stopping cross section for the inverted system may be available and serve as a first estimate. It is suggested to build in reciprocity as a fundamental requirement into empirical interpolation schemes directed at the stopping of low-velocity ions. Examination of the SRIM and MSTAR codes reveals cases where reciprocity is obeyed accurately, but deviations of up to a factor of two are common. In case of heavy ions such as gold, electronic stopping cross sections predicted by SRIM are asserted to be almost an order of magnitude too high.
Evaluating deviations in prostatectomy patients treated with IMRT.
Sá, Ana Cravo; Peres, Ana; Pereira, Mónica; Coelho, Carina Marques; Monsanto, Fátima; Macedo, Ana; Lamas, Adrian
2016-01-01
To evaluate the deviations in prostatectomy patients treated with IMRT in order to calculate appropriate margins to create the PTV. Defining inappropriate margins can lead to underdosing in target volumes and also overdosing in healthy tissues, increasing morbidity. 223 CBCT images used for alignment with the CT planning scan based on bony anatomy were analyzed in 12 patients treated with IMRT following prostatectomy. Shifts of CBCT images were recorded in three directions to calculate the required margin to create PTV. The mean and standard deviation (SD) values in millimetres were -0.05 ± 1.35 in the LR direction, -0.03 ± 0.65 in the SI direction and -0.02 ± 2.05 the AP direction. The systematic error measured in the LR, SI and AP direction were 1.35 mm, 0.65 mm, and 2.05 mm with a random error of 2.07 mm; 1.45 mm and 3.16 mm, resulting in a PTV margin of 4.82 mm; 2.64 mm, and 7.33 mm, respectively. With IGRT we suggest a margin of 5 mm, 3 mm and 8 mm in the LR, SI and AP direction, respectively, to PTV1 and PTV2. Therefore, this study supports an anisotropic margin expansion to the PTV being the largest expansion in the AP direction and lower in SI.
NASA Astrophysics Data System (ADS)
Zhu, Xiaowei; Iungo, G. Valerio; Leonardi, Stefano; Anderson, William
2017-02-01
For a horizontally homogeneous, neutrally stratified atmospheric boundary layer (ABL), aerodynamic roughness length, z_0, is the effective elevation at which the streamwise component of mean velocity is zero. A priori prediction of z_0 based on topographic attributes remains an open line of inquiry in planetary boundary-layer research. Urban topographies - the topic of this study - exhibit spatial heterogeneities associated with variability of building height, width, and proximity with adjacent buildings; such variability renders a priori, prognostic z_0 models appealing. Here, large-eddy simulation (LES) has been used in an extensive parametric study to characterize the ABL response (and z_0) to a range of synthetic, urban-like topographies wherein statistical moments of the topography have been systematically varied. Using LES results, we determined the hierarchical influence of topographic moments relevant to setting z_0. We demonstrate that standard deviation and skewness are important, while kurtosis is negligible. This finding is reconciled with a model recently proposed by Flack and Schultz (J Fluids Eng 132:041203-1-041203-10, 2010), who demonstrate that z_0 can be modelled with standard deviation and skewness, and two empirical coefficients (one for each moment). We find that the empirical coefficient related to skewness is not constant, but exhibits a dependence on standard deviation over certain ranges. For idealized, quasi-uniform cubic topographies and for complex, fully random urban-like topographies, we demonstrate strong performance of the generalized Flack and Schultz model against contemporary roughness correlations.
Neoclassical canons of facial beauty: Do we see the deviations?
Pavlic, Andrej; Trinajstic Zrinski, Magda; Katic, Visnja; Spalj, Stjepan
2017-05-01
To explore the presence of neoclassical canons of facial beauty among young people in Croatia and to question possible psychosocial repercussions occurring in those who demonstrate deviations in relation to canons. The study was cross-sectional and the sample included 249 subjects (60% female) aged 12-39 (median 20). Their en face and profile photographs were taken in Natural Head Position. Photogrammetry included analysis of nine neoclassical canons of facial beauty originating from the Renaissance. Psychosocial issues were assessed using the Self-Esteem Scale, Big Five Inventory and three domains of Orthognathic Quality of Life Questionnaire. Significant deviations from neoclassical facial beauty canons were observed in 55-65% of adolescents and young adults. Gender and age showed no relation to deviations. The deviations from canons that influenced the quality of life were mainly those related to vertical facial proportions and demonstrated increased facial aesthetics concern and social impact, and higher self-reported treatment need (p < 0.05). Deviations from canons were not related to self-esteem but a decrease in openness, agreeableness and neuroticism was observed. Neoclassical canons were not valid for the majority of adolescents and young adults in Croatia. Only deviations from some canons appear to provoke mild psychosocial repercussions. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Wang, Zhiguo; Theeuwes, Jan
2014-01-01
Previous studies have shown that saccades may deviate towards or away from task irrelevant visual distractors. This observation has been attributed to active suppression (inhibition) of the distractor location unfolding over time: early in time inhibition at the distractor location is incomplete causing deviation towards the distractor, while later in time when inhibition is complete the eyes deviate away from the distractor. In a recent computational study, Wang, Kruijne and Theeuwes proposed an alternative theory that the lateral interactions in the superior colliculus (SC), which are characterized by short-distance excitation and long-distance inhibition, are sufficient for generating both deviations towards and away from distractors. In the present study, we performed a meta-analysis of the literature, ran model simulations and conducted two behavioral experiments to further explore this unconventional theory. Confirming predictions generated by the model simulations, the behavioral experiments show that a) saccades deviate towards close distractors and away from remote distractors, and b) the amount of deviation depends on the strength of fixation activity in the SC, which can be manipulated by turning off the fixation stimulus before or after target onset (Experiment 1), or by varying the eccentricity of the target and distractor (Experiment 2). PMID:25551552
Research on frequency control strategy of interconnected region based on fuzzy PID
NASA Astrophysics Data System (ADS)
Zhang, Yan; Li, Chunlan
2018-05-01
In order to improve the frequency control performance of the interconnected power grid, overcome the problems of poor robustness and slow adjustment of traditional regulation, the paper puts forward a frequency control method based on fuzzy PID. The method takes the frequency deviation and tie-line deviation of each area as the control objective, takes the regional frequency deviation and its deviation as input, and uses fuzzy mathematics theory, adjusts PID control parameters online. By establishing the regional frequency control model of water-fire complementary power generation in MATLAB, the regional frequency control strategy is given, and three control modes (TBC-FTC, FTC-FTC, FFC-FTC) are simulated and analyzed. The simulation and experimental results show that, this method has better control performance compared with the traditional regional frequency regulation.
Stimuli eliciting sexual arousal in males who offend adult women: an experimental study.
Kolárský, A; Madlafousek, J; Novotná, V
1978-03-01
The sexually arousing effects of short film scenes showing a naked actress's seductive behavior were phalloplethysmographically measured in 14 sexual deviates. These were males who had offended adult women, predominantly exhibitionists. Controls were 14 normal men. Deviates responded positively to the scenes and differentiated strong and weak seduction scenes similarly to normals. Consequently, the question arises of why deviates avoid their victim's erotic cooperation and why they do not offend their regular sexual partners. Post hoc analysis of five scenes which elicited a strikingly higher response in deviates than in normals suggested that these scenes contained reduced seductive behavior but unrestrained presentation of the genitals. This finding further encourages the laboratory study of stimulus conditions for abnormal sexual arousal which occurs during the sexual offense.
Scaling Deviations for Neutrino Reactions in Aysmptotically Free Field Theories
DOE R&D Accomplishments Database
Wilczek, F. A.; Zee, A.; Treiman, S. B.
1974-11-01
Several aspects of deep inelastic neutrino scattering are discussed in the framework of asymptotically free field theories. We first consider the growth behavior of the total cross sections at large energies. Because of the deviations from strict scaling which are characteristic of such theories the growth need not be linear. However, upper and lower bounds are established which rather closely bracket a linear growth. We next consider in more detail the expected pattern of scaling deviation for the structure functions and, correspondingly, for the differential cross sections. The analysis here is based on certain speculative assumptions. The focus is on qualitative effects of scaling breakdown as they may show up in the X and y distributions. The last section of the paper deals with deviations from the Callan-Gross relation.
Jannink, I; Bennen, J N; Blaauw, J; van Diest, P J; Baak, J P
1995-01-01
This study compares the influence of two different nuclear sampling methods on the prognostic value of assessments of mean and standard deviation of nuclear area (MNA, SDNA) in 191 consecutive invasive breast cancer patients with long term follow up. The first sampling method used was 'at convenience' sampling (ACS); the second, systematic random sampling (SRS). Both sampling methods were tested with a sample size of 50 nuclei (ACS-50 and SRS-50). To determine whether, besides the sampling methods, sample size had impact on prognostic value as well, the SRS method was also tested using a sample size of 100 nuclei (SRS-100). SDNA values were systematically lower for ACS, obviously due to (unconsciously) not including small and large nuclei. Testing prognostic value of a series of cut off points, MNA and SDNA values assessed by the SRS method were prognostically significantly stronger than the values obtained by the ACS method. This was confirmed in Cox regression analysis. For the MNA, the Mantel-Cox p-values from SRS-50 and SRS-100 measurements were not significantly different. However, for the SDNA, SRS-100 yielded significantly lower p-values than SRS-50. In conclusion, compared with the 'at convenience' nuclear sampling method, systematic random sampling of nuclei is not only superior with respect to reproducibility of results, but also provides a better prognostic value in patients with invasive breast cancer.
Tongue retaining devices for obstructive sleep apnea: A systematic review and meta-analysis.
Chang, Edward T; Fernandez-Salvador, Camilo; Giambo, Jeremy; Nesbitt, Blaine; Liu, Stanley Yung-Chuan; Capasso, Robson; Kushida, Clete A; Camacho, Macario
Tongue Retaining Devices (TRD) anteriorly displace the tongue with suction forces while patients sleep. TRD provide a non-surgical treatment option for patients with Obstructive Sleep Apnea (OSA). Our objective was to conduct a systematic review of the international literature for TRD outcomes as treatment for OSA. Three authors independently and systematically searched four databases (including PubMed/MEDLINE) through June 26, 2016. We followed guidelines set within the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Sixteen studies with 242 patients met criteria. The overall means±standard deviations (M±SD) for apnea-hypopnea index (AHI) decreased from 33.6±21.1/h to 15.8±16.0/h (53% reduction). Seven studies (81 patients) reported lowest oxygen saturation (LSAT), which improved from 79.8±17.5% to 83.9±8.6%. Four studies (93 patients) reported Epworth sleepiness scale (ESS), which decreased from 10.8±4.8 to 8.2±4.5, p <0.0001. Four studies (31 patients) reported Oxygen Desaturation Index (ODI) which decreased from 29.6±32.1 to 12.9±8.7, a 56.4% reduction. Current international literature demonstrates that tongue retaining devices reduce apnea-hypopnea index by 53%, increase lowest oxygen saturation by 4.1 oxygen saturation points, decrease oxygen desaturation index by 56% and decrease Epworth sleepiness scale scores by 2.8 points. Tongue retaining devices provide a statistically effective alternative treatment option for obstructive sleep apnea. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Muji Susantoro, Tri; Wikantika, Ketut; Saepuloh, Asep; Handoyo Harsolumakso, Agus
2018-05-01
Selection of vegetation indices in plant mapping is needed to provide the best information of plant conditions. The methods used in this research are the standard deviation and the linear regression. This research tried to determine the vegetation indices used for mapping the sugarcane conditions around oil and gas fields. The data used in this study is Landsat 8 OLI/TIRS. The standard deviation analysis on the 23 vegetation indices with 27 samples has resulted in the six highest standard deviations of vegetation indices, termed as GRVI, SR, NLI, SIPI, GEMI and LAI. The standard deviation values are 0.47; 0.43; 0.30; 0.17; 0.16 and 0.13. Regression correlation analysis on the 23 vegetation indices with 280 samples has resulted in the six vegetation indices, termed as NDVI, ENDVI, GDVI, VARI, LAI and SIPI. This was performed based on regression correlation with the lowest value R2 than 0,8. The combined analysis of the standard deviation and the regression correlation has obtained the five vegetation indices, termed as NDVI, ENDVI, GDVI, LAI and SIPI. The results of the analysis of both methods show that a combination of two methods needs to be done to produce a good analysis of sugarcane conditions. It has been clarified through field surveys and showed good results for the prediction of microseepages.
Perception of midline deviations in smile esthetics by laypersons
Ferreira, Jamille Barros; da Silva, Licínio Esmeraldo; Caetano, Márcia Tereza de Oliveira; da Motta, Andrea Fonseca Jardim; Cury-Saramago, Adriana de Alcantara; Mucha, José Nelson
2016-01-01
ABSTRACT Objective: To evaluate the esthetic perception of upper dental midline deviation by laypersons and if adjacent structures influence their judgment. Methods: An album with 12 randomly distributed frontal view photographs of the smile of a woman with the midline digitally deviated was evaluated by 95 laypersons. The frontal view smiling photograph was modified to create from 1 mm to 5 mm deviations in the upper midline to the left side. The photographs were cropped in two different manners and divided into two groups of six photographs each: group LCN included the lips, chin, and two-thirds of the nose, and group L included the lips only. The laypersons performed the rate of each smile using a visual analog scale (VAS). Wilcoxon test, Student’s t-test and Mann-Whitney test were applied, adopting a 5% level of significance. Results: Laypersons were able to perceive midline deviations starting at 1 mm. Statistically significant results (p< 0.05) were found for all multiple comparisons of the values in photographs of group LCN and for almost all comparisons in photographs of group L. Comparisons between the photographs of groups LCN and L showed statistically significant values (p< 0.05) when the deviation was 1 mm. Conclusions: Laypersons were able to perceive the upper dental midline deviations of 1 mm, and above when the adjacent structures of the smiles were included. Deviations of 2 mm and above when the lips only were included. The visualization of structures adjacent to the smile demonstrated influence on the perception of midline deviation. PMID:28125140
Influence of asymmetrical drawing radius deviation in micro deep drawing
NASA Astrophysics Data System (ADS)
Heinrich, L.; Kobayashi, H.; Shimizu, T.; Yang, M.; Vollertsen, F.
2017-09-01
Nowadays, an increasing demand for small metal parts in electronic and automotive industries can be observed. Deep drawing is a well-suited technology for the production of such parts due to its excellent qualities for mass production. However, the downscaling of the forming process leads to new challenges in tooling and process design, such as high relative deviation of tool geometry or blank displacement compared to the macro scale. FEM simulation has been a widely-used tool to investigate the influence of symmetrical process deviations as for instance a global variance of the drawing radius. This study shows a different approach that allows to determine the impact of asymmetrical process deviations on micro deep drawing. In this particular case the impact of an asymmetrical drawing radius deviation and blank displacement on cup geometry deviation was investigated for different drawing ratios by experiments and FEM simulation. It was found that both variations result in an increasing cup height deviation. Nevertheless, with increasing drawing ratio a constant drawing radius deviation has an increasing impact, while blank displacement results in a decreasing offset of the cups geometry. This is explained by different mechanisms that result in an uneven cup geometry. While blank displacement leads to material surplus on one side of the cup, an unsymmetrical radius deviation on the other hand generates uneven stretching of the cups wall. This is intensified for higher drawing ratios. It can be concluded that the effect of uneven radius geometry proves to be of major importance for the production of accurately shaped micro cups and cannot be compensated by intentional blank displacement.
Predictive model for disinfection by-product in Alexandria drinking water, northern west of Egypt.
Abdullah, Ali M; Hussona, Salah El-dien
2013-10-01
Chlorine has been utilized in the early stages of water treatment processes as disinfectant. Disinfection for drinking water reduces the risk of pathogenic infection but may pose a chemical threat to human health due to disinfection residues and their by-products (DBP) when the organic and inorganic precursors are present in water. In the last two decades, many modeling attempts have been made to predict the occurrence of DBP in drinking water. Models have been developed based on data generated in laboratory-scale and field-scale investigations. The objective of this paper is to develop a predictive model for DBP formation in the Alexandria governorate located at the northern west of Egypt based on field-scale investigations as well as laboratory-controlled experimentations. The present study showed that the correlation coefficient between trihalomethanes (THM) predicted and THM measured was R (2)=0.88 and the minimum deviation percentage between THM predicted and THM measured was 0.8 %, the maximum deviation percentage was 89.3 %, and the average deviation was 17.8 %, while the correlation coefficient between dichloroacetic acid (DCAA) predicted and DCAA measured was R (2)=0.98 and the minimum deviation percentage between DCAA predicted and DCAA measured was 1.3 %, the maximum deviation percentage was 47.2 %, and the average deviation was 16.6 %. In addition, the correlation coefficient between trichloroacetic acid (TCAA) predicted and TCAA measured was R (2)=0.98 and the minimum deviation percentage between TCAA predicted and TCAA measured was 4.9 %, the maximum deviation percentage was 43.0 %, and the average deviation was 16.0 %.
Screen Twice, Cut Once: Assessing the Predictive Validity of Teacher Selection Tools
ERIC Educational Resources Information Center
Goldhaber, Dan; Grout, Cyrus; Huntington-Klein, Nick
2015-01-01
It is well documented that teachers can have profound effects on student outcomes. Empirical estimates find that a one standard deviation increase in teacher quality raises student test achievement by 10 to 25 percent of a standard deviation. More recent evidence shows that the effectiveness of teachers can affect long-term student outcomes, such…
Assessment of visceral pain associated with metritis in dairy cows.
Stojkov, J; von Keyserlingk, M A G; Marchant-Forde, J N; Weary, D M
2015-08-01
Metritis is a common disease in dairy cattle, but to our knowledge, no work has assessed pain associated with this disease. Tissue palpation is commonly used to assess pain in human and veterinary medicine. The objective of this study was to evaluate visceral pain responses during rectal palpation, with and without uterine palpation, in healthy cows and in cows diagnosed with metritis. A total of 49 Holstein dairy cows (mean ± standard deviation parity of 2.8±1.8) were subjected to systematic health checks every 3 d after parturition for 21 d, scoring for vaginal discharge (0 to 4); 13 cows showed a discharge score ≥2 during at least 1 health check and were classified as metritic, whereas 29 cows were classified as healthy and showed no sign of this or any other disease (including mastitis and lameness). Back arch and heart rate variability before examination and during palpation were recorded using video and heart rate monitors. Back arch (cm(2)) on the day of diagnosis was greater in metritic versus healthy cows (1,034±72 vs. 612±48cm(2)), and greater during rectal palpation with uterine palpation versus rectal palpation without uterine palpation (869±45 vs. 777±45cm(2)). Heart rate frequency domain analysis showed that the low-frequency portion was higher in cows with metritis versus healthy cows (16.5±1.2 vs. 12.9±1.0). Time domain analysis showed that the standard deviation between normal to normal interbeat intervals and the root mean square of successive differences both decreased during rectal palpation with uterine palpation versus rectal palpation without uterine palpation (1.9±0.1 vs. 2.5±0.1 and 1.3±0.1 vs. 1.7±0.1, respectively). Together, these results indicate that the inflammation associated with metritis is painful, and that the pain response can be detected during rectal palpation with and without uterine palpation. Rectal palpation with uterine palpation appears to be more aversive than rectal palpation without uterine palpation, suggesting that the former should be avoided when possible. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Global carbonyl sulfide (OCS) measured by MIPAS/Envisat during 2002-2012
NASA Astrophysics Data System (ADS)
Glatthor, Norbert; Höpfner, Michael; Leyser, Adrian; Stiller, Gabriele P.; von Clarmann, Thomas; Grabowski, Udo; Kellmann, Sylvia; Linden, Andrea; Sinnhuber, Björn-Martin; Krysztofiak, Gisèle; Walker, Kaley A.
2017-02-01
We present a global carbonyl sulfide (OCS) data set covering the period June 2002 to April 2012, derived from FTIR (Fourier transform infrared) limb emission spectra measured with the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) on the ENVISAT satellite. The vertical resolution is 4-5 km in the height region 6-15 km and 15 at 40 km altitude. The total estimated error amounts to 40-50 pptv between 10 and 20 km and to 120 pptv at 40 km altitude. MIPAS OCS data show no systematic bias with respect to balloon observations, with deviations mostly below ±50 pptv. However, they are systematically higher than the OCS volume mixing ratios of the ACE-FTS instrument on SCISAT, with maximum deviations of up to 100 pptv in the altitude region 13-16 km. The data set of MIPAS OCS exhibits only moderate interannual variations and low interhemispheric differences. Average concentrations at 10 km altitude range from 480 pptv at high latitudes to 500-510 pptv in the tropics and at northern mid-latitudes. Seasonal variations at 10 km altitude amount to up to 35 pptv in the Northern and up to 15 pptv in the Southern Hemisphere. Northern hemispheric OCS abundances at 10 km altitude peak in June in the tropics and around October at high latitudes, while the respective southern hemispheric maxima were observed in July and in November. Global OCS distributions at 250 hPa (˜ 10-11 km) show enhanced values at low latitudes, peaking during boreal summer above the western Pacific and the Indian Ocean, which indicates oceanic release. Further, a region of depleted OCS amounts extending from Brazil to central and southern Africa was detected at this altitude, which is most pronounced in austral summer. This depletion is related to seasonally varying vegetative uptake by the tropical forests. Typical signatures of biomass burning like the southern hemispheric biomass burning plume are not visible in MIPAS data, indicating that this process is only a minor source of upper tropospheric OCS. At the 150 hPa level (˜ 13-14 km) enhanced amounts of OCS were also observed inside the Asian monsoon anticyclone, but this enhancement is not especially outstanding compared to other low latitude regions at the same altitude. At the 80 hPa level (˜ 17-18 km), equatorward transport of mid-latitude air masses containing lower OCS amounts around the summertime anticyclones was observed. A significant trend could not be detected in upper tropospheric MIPAS OCS amounts, which points to globally balanced sources and sinks. Simulations with the ECHAM-MESSy model reproduce the observed latitudinal cross sections fairly well.
Han, Julia L; Gandhi, Shreyas; Bockoven, Crystal G; Narayan, Vikram M; Dahm, Philipp
2017-04-01
To assess the quality of published systematic reviews in the urology literature (an extension of our previously reported work), as high-quality systematic reviews play a paramount role in informing evidence-based clinical practice. Our focus was on systematic reviews in the urology literature that incorporated questions of prevention and therapy. To identify such reviews published during a 36-month period (2013-2015), we systematically searched PubMed and hand-searched the table of contents of four major urology journals. Two reviewers independently assessed the methodological quality of those reviews, using the 11-point 'Assessment of Multiple Systematic Reviews' (AMSTAR) instrument. We performed protocol-driven analyses of the data from our present study's 36-month period alone, as well as in aggregate with the data from our previously reported work's study periods (2009-2012 and 1998-2008). In our literature search of the 36-month period (2013-2015), we initially identified 490 possibly relevant reviews, of which 125 met our inclusion criteria. The most common topic of reviews for the 2013-2015 period was oncology (51.2%; n = 64), followed by voiding dysfunction (21.6%; n = 27). The mean [standard deviation (SD)] AMSTAR score in the 2013-2015 period (n = 125) was 4.8 (2.4); 2009-2012 (n = 113), 5.4 (2.3); and 1998-2008 (n = 57), 4.8 (2.0) (P = 0.127). In the 2013-2015 period, the mean (SD) AMSTAR score for the BJU International (n = 25) was 5.6 (2.9); for The Journal of Urology (n = 20), 5.1 (2.6); for European Urology (n = 60), 4.5 (2.2); and for Urology (n = 20), 4.4 (2.2) (P = 0.106). The number of systematic reviews published in the urology literature has exponentially increased, year by year, but their methodological quality has stagnated. To enhance the validity and impact of systematic reviews, all authors and editors must apply established methodological standards. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.
Cumulants and large deviations of the current through non-equilibrium steady states
NASA Astrophysics Data System (ADS)
Bodineau, Thierry; Derrida, Bernard
2007-06-01
Using a generalisation of detailed balance for systems maintained out of equilibrium by contact with 2 reservoirs at unequal temperatures or at unequal densities, one can recover the fluctuation theorem for the large deviation function of the current. For large diffusive systems, we show how the large deviation function of the current can be computed using a simple additivity principle. The validity of this additivity principle and the occurrence of phase transitions are discussed in the framework of the macroscopic fluctuation theory. To cite this article: T. Bodineau, B. Derrida, C. R. Physique 8 (2007).
Higher-order geodesic deviation for charged particles and resonance induced by gravitational waves
NASA Astrophysics Data System (ADS)
Heydari-Fard, M.; Hasani, S. N.
We generalize the higher-order geodesic deviation for the structure-less test particles to the higher-order geodesic deviation equations of the charged particles [R. Kerner, J. W. van Holten and R. Colistete Jr., Class. Quantum Grav. 18 (2001) 4725]. By solving these equations for charged particles moving in a constant magnetic field in the spacetime of a gravitational wave, we show for both cases when the gravitational wave is parallel and perpendicular to the constant magnetic field, a magnetic resonance appears at wg = Ω. This feature might be useful to detect the gravitational wave with high frequencies.
Importance sampling large deviations in nonequilibrium steady states. I.
Ray, Ushnish; Chan, Garnet Kin-Lic; Limmer, David T
2018-03-28
Large deviation functions contain information on the stability and response of systems driven into nonequilibrium steady states and in such a way are similar to free energies for systems at equilibrium. As with equilibrium free energies, evaluating large deviation functions numerically for all but the simplest systems is difficult because by construction they depend on exponentially rare events. In this first paper of a series, we evaluate different trajectory-based sampling methods capable of computing large deviation functions of time integrated observables within nonequilibrium steady states. We illustrate some convergence criteria and best practices using a number of different models, including a biased Brownian walker, a driven lattice gas, and a model of self-assembly. We show how two popular methods for sampling trajectory ensembles, transition path sampling and diffusion Monte Carlo, suffer from exponentially diverging correlations in trajectory space as a function of the bias parameter when estimating large deviation functions. Improving the efficiencies of these algorithms requires introducing guiding functions for the trajectories.
Importance sampling large deviations in nonequilibrium steady states. I
NASA Astrophysics Data System (ADS)
Ray, Ushnish; Chan, Garnet Kin-Lic; Limmer, David T.
2018-03-01
Large deviation functions contain information on the stability and response of systems driven into nonequilibrium steady states and in such a way are similar to free energies for systems at equilibrium. As with equilibrium free energies, evaluating large deviation functions numerically for all but the simplest systems is difficult because by construction they depend on exponentially rare events. In this first paper of a series, we evaluate different trajectory-based sampling methods capable of computing large deviation functions of time integrated observables within nonequilibrium steady states. We illustrate some convergence criteria and best practices using a number of different models, including a biased Brownian walker, a driven lattice gas, and a model of self-assembly. We show how two popular methods for sampling trajectory ensembles, transition path sampling and diffusion Monte Carlo, suffer from exponentially diverging correlations in trajectory space as a function of the bias parameter when estimating large deviation functions. Improving the efficiencies of these algorithms requires introducing guiding functions for the trajectories.
Dukic, T; Hanson, L; Falkmer, T
2006-01-15
The study examined the effects of manual control locations on two groups of randomly selected young and old drivers in relation to visual time off road, steering wheel deviation and safety perception. Measures of visual time off road, steering wheel deviations and safety perception were performed with young and old drivers during real traffic. The results showed an effect of both driver's age and button location on the dependent variables. Older drivers spent longer visual time off road when pushing the buttons and had larger steering wheel deviations. Moreover, the greater the eccentricity between the normal line of sight and the button locations, the longer the visual time off road and the larger the steering wheel deviations. No interaction effect between button location and age was found with regard to visual time off road. Button location had an effect on perceived safety: the further away from the normal line of sight the lower the rating.
Zijlstra, Eric; Heinemann, Lutz; Fischer, Annelie; Kapitza, Christoph
2016-01-01
Background: The objective was to evaluate the performance (in terms of accuracy, precision, and trueness) of 5 CE-certified and commercially available blood glucose (BG) systems (meters plus test strips) using an innovative clinical-experimental study design with a 3-step glucose clamp approach and frequent capillary BG measurements. Methods: Sixteen subjects with type 1 diabetes participated in this open label, single center trial. BG was clamped at 3 levels for 60 minutes each: 60-100-200 mg/dL. Medical staff performed regular finger pricks (up to 10 per BG level) to obtain capillary blood samples for paired BG measurements with the 5 BG systems and a laboratory method as comparison. Results: Three BG systems displayed significantly lower mean absolute relative deviations (MARD) (ACCU-Chek® Aviva Nano [5.4%], BGStar® [5.1%], iBGStar® [5.3%]) than 2 others (FreeStyle InsuLinx® [7.7%], OneTouch Verio®IQ [10.3%]). The measurement precision of all BG systems was comparable, but relative bias was also lower for the 3 systems with lower MARD (ACCU-Chek [1.3%], BGStar [–0.9%], iBGStar [1.0%]) compared with the 2 others (FreeStyle [–7.2%], OneTouch [8.9%]). Conclusions: This 3 range glucose clamp approach enables a systematic performance evaluation of BG systems under controlled and reproducible conditions. The random error of the tested BG systems was comparable, but some showed a lower systematic error than others. These BG systems allow an accurate glucose measurement at low, normal and high BG levels. PMID:27605592
Santos, Roberto G; Santos, Rachel Boba
2015-10-01
Police agencies around the country are implementing various strategies to reduce crime in their communities that need to be evaluated. These strategies are often based on systematic crime analysis and are focused on crime occurring in hot spots, which are areas of disproportionate amounts of crime. This article takes a practice-based research approach to evaluate whether evidence-based police strategies implemented by one police agency as its normal everyday crime reduction practice are effective in reducing residential burglary incidents in micro-time hot spots. A quasi-experimental ex post facto design is employed using 5 years of data from one police agency that has institutionalized the identification and response to micro-time hot spots into its day-to-day practices. Propensity score matching is used to match 54 pairs of micro-time hot spots using logistic regression to compute the propensity scores and greedy 1 to 1 matching with a caliper width of 0.5 of the standard deviation of the logit to match the cases. Independent t-tests show that tactical police response to micro-time hot spots can lead to significant reductions in residential burglary incidents without the spatial displacement of crime. Tactical police responses that seek to achieve short-term reductions in crime appear to be well suited for micro-time hot spots since they are, by nature, short term. Importantly, the conclusions are based on the evaluation of an agency's systematic implementation of the evidence-based practices as its normal practices and not for the sake of research. © The Author(s) 2015.
Zijlstra, Eric; Heinemann, Lutz; Fischer, Annelie; Kapitza, Christoph
2016-11-01
The objective was to evaluate the performance (in terms of accuracy, precision, and trueness) of 5 CE-certified and commercially available blood glucose (BG) systems (meters plus test strips) using an innovative clinical-experimental study design with a 3-step glucose clamp approach and frequent capillary BG measurements. Sixteen subjects with type 1 diabetes participated in this open label, single center trial. BG was clamped at 3 levels for 60 minutes each: 60-100-200 mg/dL. Medical staff performed regular finger pricks (up to 10 per BG level) to obtain capillary blood samples for paired BG measurements with the 5 BG systems and a laboratory method as comparison. Three BG systems displayed significantly lower mean absolute relative deviations (MARD) (ACCU-Chek® Aviva Nano [5.4%], BGStar® [5.1%], iBGStar® [5.3%]) than 2 others (FreeStyle InsuLinx® [7.7%], OneTouch Verio®IQ [10.3%]). The measurement precision of all BG systems was comparable, but relative bias was also lower for the 3 systems with lower MARD (ACCU-Chek [1.3%], BGStar [-0.9%], iBGStar [1.0%]) compared with the 2 others (FreeStyle [-7.2%], OneTouch [8.9%]). This 3 range glucose clamp approach enables a systematic performance evaluation of BG systems under controlled and reproducible conditions. The random error of the tested BG systems was comparable, but some showed a lower systematic error than others. These BG systems allow an accurate glucose measurement at low, normal and high BG levels. © 2016 Diabetes Technology Society.
Root, Katharina; Wittwer, Yves; Barylyuk, Konstantin; Anders, Ulrike; Zenobi, Renato
2017-09-01
Native ESI-MS is increasingly used for quantitative analysis of biomolecular interactions. In such analyses, peak intensity ratios measured in mass spectra are treated as abundance ratios of the respective molecules in solution. While signal intensities of similar-size analytes, such as a protein and its complex with a small molecule, can be directly compared, significant distortions of the peak ratio due to unequal signal response of analytes impede the application of this approach for large oligomeric biomolecular complexes. We use a model system based on concatenated maltose binding protein units (MBPn, n = 1, 2, 3) to systematically study the behavior of protein mixtures in ESI-MS. The MBP concatamers differ from each other only by their mass while the chemical composition and other properties remain identical. We used native ESI-MS to analyze model mixtures of MBP oligomers, including equimolar mixtures of two proteins, as well as binary mixtures containing different fractions of the individual components. Pronounced deviation from a linear dependence of the signal intensity with concentration was observed for all binary mixtures investigated. While equimolar mixtures showed linear signal dependence at low concentrations, distinct ion suppression was observed above 20 μM. We systematically studied factors that are most often used in the literature to explain the origin of suppression effects. Implications of this effect for quantifying protein-protein binding affinity by native ESI-MS are discussed in general and demonstrated for an example of an anti-MBP antibody with its ligand, MBP. Graphical Abstract ᅟ.
NASA Astrophysics Data System (ADS)
Ramos, S. B.; González Lemus, N. V.; Deluque Toro, C. E.; Cabeza, G. F.; Fernández Guillermet, A.
2017-07-01
Motivated by the high solubility of In in ( mC44) η'-Cu6Sn5 compound as well as the occurrence of an In-doped η'-intermetallic in the microstructure of Cu/In-Sn/Cu solder joints, a theoretical study has been carried out to investigate the various physical effects of incorporating In at Sn Wyckoff sites of the binary η'-phase. Systematic ab initio calculations using the projected augmented wave method and Vienna Ab initio Simulation Package were used to determine the composition dependence of the structural and cohesive properties of η'-Cu6(Sn,In)5 compounds, compared with those expected from the binary end-member compounds Cu6Sn5 and Cu6In5. The molar volume shows significant deviations from Vegard's law. The predicted composition dependence of the cohesive properties is discussed using two complementary approaches, viz. a valence-electron density approach as well as a bond-number approach, both accounting for the roughly linear dependence of the cohesive energy on the In content. A microscopic interpretation for this general trend is given in terms of the key contributions to chemical bonding in this class of compounds, namely Cu d-electron overlap and hybridization of Cu d-states with In and Sn p-electron states. Moreover, a crystallographic site approach is developed to accurately establish the phase-stabilizing effect of incorporating In at specific Wyckoff positions of the ( mC44) η'-Cu6Sn5 structure.
Can decision making in general surgery be based on evidence? An empirical study of Cochrane Reviews.
Diener, Markus K; Wolff, Robert F; von Elm, Erik; Rahbari, Nuh N; Mavergames, Chris; Knaebel, Hanns-Peter; Seiler, Christoph M; Antes, Gerd
2009-09-01
This empirical study analyzes the current status of Cochrane Reviews (CRs) and their strength of recommendation for evidence-based decision making in the field of general surgery. Systematic literature search of the Cochrane Database of Systematic Reviews and the Cochrane Collaboration's homepage to identify available CRs on surgical topics. Quantitative and qualitative characteristics, utilization, and formulated treatment recommendations were evaluated by 2 independent reviewers. Association of review characteristics with treatment recommendation was analyzed using univariate and multivariate logistic regression models. Ninety-three CRs, including 1,403 primary studies and 246,473 patients, were identified. Mean number of included primary studies per CR was 15.1 (standard deviation [SD] 14.5) including 2,650 (SD 3,340) study patients. Two and a half (SD 8.3) nonrandomized trials were included per analyzed CR. Seventy-two (77%) CRs were published or updated in 2005 or later. Explicit treatment recommendations were given in 45 (48%). Presence of a treatment recommendation was associated with the number of included primary studies and the proportion of randomized studies. Utilization of surgical CRs remained low and showed large inter-country differences. The most surgical CRs were accessed in UK, USA, and Australia, followed by several Western and Eastern European countries. Only a minority of available CRs address surgical questions and their current usage is low. Instead of unsystematically increasing the number of surgical CRs it would be far more efficient to focus the review process on relevant surgical questions. Prioritization of CRs needs valid methods which should be developed by the scientific surgical community.
Can reduction of uncertainties in cervix cancer brachytherapy potentially improve clinical outcome?
Nesvacil, Nicole; Tanderup, Kari; Lindegaard, Jacob C; Pötter, Richard; Kirisits, Christian
2016-09-01
The aim of this study was to quantify the impact of different types and magnitudes of dosimetric uncertainties in cervix cancer brachytherapy (BT) on tumour control probability (TCP) and normal tissue complication probability (NTCP) curves. A dose-response simulation study was based on systematic and random dose uncertainties and TCP/NTCP models for CTV and rectum. Large patient cohorts were simulated assuming different levels of dosimetric uncertainties. TCP and NTCP were computed, based on the planned doses, the simulated dose uncertainty, and an underlying TCP/NTCP model. Systematic uncertainties of 3-20% and random uncertainties with a 5-30% standard deviation per BT fraction were analysed. Systematic dose uncertainties of 5% lead to a 1% decrease/increase of TCP/NTCP, while random uncertainties of 10% had negligible impact on the dose-response curve at clinically relevant dose levels for target and OAR. Random OAR dose uncertainties of 30% resulted in an NTCP increase of 3-4% for planned doses of 70-80Gy EQD2. TCP is robust to dosimetric uncertainties when dose prescription is in the more flat region of the dose-response curve at doses >75Gy. For OARs, improved clinical outcome is expected by reduction of uncertainties via sophisticated dose delivery and treatment verification. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Effect of stoichiometry on magnetic and transport properties in polycrystalline Y2Ir2O7
NASA Astrophysics Data System (ADS)
Dwivedi, Vinod Kumar; Mukhopadhyay, Soumik
2018-05-01
In this paper we discuss synthesis of polycrystalline Y2Ir2O7 by solid state reaction route. XRD analysis shows deviation from stoichiometry which is also confirmed by SEM-EDX analysis. SEM analysis indicates average particle size ranging from 100 nm to 800 µm. EDX analysis gives clear evidence for deviation of stoichiometry of the product. Magnetic analysis is indicating effect of stoichiometry and showing ferromagnetic interaction unlike antiferromagnetic feature. Electrical resistivity is showing similar behavior as reported earlier and reveals no effect of different size of grains or grain boundaries from room temperature to 125 K.
Glide path preparation in S-shaped canals with rotary pathfinding nickel-titanium instruments.
Ajuz, Natasha C C; Armada, Luciana; Gonçalves, Lucio S; Debelian, Gilberto; Siqueira, José F
2013-04-01
This study compared the incidence of deviation along S-shaped (double-curved) canals after glide path preparation with 2 nickel-titanium (NiTi) rotary pathfinding instruments and hand K-files. S-shaped canals from 60 training blocks were filled with ink, and preinstrumentation images were obtained by using a stereomicroscope. Glide path preparation was performed by an endodontist who used hand stainless steel K-files (up to size 20), rotary NiTi PathFile instruments (up to size 19), or rotary NiTi Scout RaCe instruments (up to size 20). Postinstrumentation images were taken by using exactly the same conditions as for the preinstrumentation images, and both pictures were superimposed. Differences along the S-shaped canal for the mesial and distal aspects were measured to evaluate the occurrence of deviation. Intragroup analysis showed that all instruments promoted some deviation in virtually all levels. Overall, regardless of the group, deviations were observed in the mesial wall at the canal terminus and at levels 4, 5, 6 and 7 mm and in the distal wall at levels 1, 2, and 3 mm. These levels corresponded to the inner walls of each curvature. Both rotary NiTi instruments performed significantly better than hand K-files at all levels (P < .05), except for PathFiles at the 0-mm level. ScoutRaCe instruments showed significantly better results than PathFiles at levels 0, 2, 3, 5, and 6 mm (P < .05). Findings suggest that rotary NiTi instruments are suitable for adequate glide path preparation because they promoted less deviation from the original canal anatomy when compared with hand-operated instruments. Of the 2 rotary pathfinding instruments, Scout RaCe showed an overall significantly better performance. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Pasler, Marlies; Michel, Kilian; Marrazzo, Livia; Obenland, Michael; Pallotta, Stefania; Björnsgard, Mari; Lutterbach, Johannes
2017-09-01
The purpose of this study was to characterize a new single large-area ionization chamber, the integral quality monitor system (iRT, Germany), for online and real-time beam monitoring. Signal stability, monitor unit (MU) linearity and dose rate dependence were investigated for static and arc deliveries and compared to independent ionization chamber measurements. The dose verification capability of the transmission detector system was evaluated by comparing calculated and measured detector signals for 15 volumetric modulated arc therapy plans. The error detection sensitivity was tested by introducing MLC position and linac output errors. Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation (2%/2 mm and 3%/3 mm). The detector signal is linearly dependent on linac output and shows negligible (<0.4%) dose rate dependence up to 460 MU min -1 . Signal stability is within 1% for cumulative detector output; substantial variations were observed for the segment-by-segment signal. Calculated versus measured cumulative signal deviations ranged from -0.16%-2.25%. DVH, mean 2D γ-value and detector signal evaluations showed increasing deviations with regard to the respective reference with growing MLC and dose output errors; good correlation between DVH metrics and detector signal deviation was found (e.g. PTV D mean : R 2 = 0.97). Positional MLC errors of 1 mm and errors in linac output of 2% were identified with the transmission detector system. The extensive tests performed in this investigation show that the new transmission detector provides a stable and sensitive cumulative signal output and is suitable for beam monitoring during patient treatment.
Validation of 10 years of SAO OMI Ozone Profiles with Ozonesonde and MLS Observations
NASA Astrophysics Data System (ADS)
Huang, G.; Liu, X.; Chance, K.; Bhartia, P. K.
2015-12-01
To evaluate the accuracy and long-term stability of the SAO OMI ozone profile product, we validate ~10 years of ozone profile product (Oct. 2004-Dec. 2014) against collocated ozonesonde and MLS data. Ozone profiles as well stratospheric, tropospheric, lower tropospheric ozone columns are compared with ozonesonde data for different latitude bands, and time periods (e.g., 2004-2008/2009-2014 for without/with row anomaly. The mean biases and their standard deviations are also assessed as a function of time to evaluate the long-term stability and bias trends. In the mid-latitude and tropical regions, OMI generally shows good agreement with ozonesonde observations. The mean ozone profile biases are generally within 6% with up to 30% standard deviations. The biases of stratospheric ozone columns (SOC) and tropospheric ozone columns (TOC) are -0.3%-2.2% and -0.2%-3%, while standard deviations are 3.9%-5.8% and 14.4%-16.0%, respectively. However, the retrievals during 2009-2014 show larger standard deviations and larger temporal variations; the standard deviations increase by ~5% in the troposphere and ~2% in the stratosphere. Retrieval biases at individual levels in the stratosphere and upper troposphere show statistically significant trends and different trends for 2004-2008 and 2009-2014 periods. The trends in integrated ozone partial columns are less significant due to cancellation from various layers, except for significant trend in tropical SOC. These results suggest the need to perform time dependent radiometric calibration to maintain the long-term stability of this product. Similarly, we are comparing the OMI stratospheric ozone profiles and SOC with collocated MLS data, and the results will be reported.
NASA Astrophysics Data System (ADS)
Pasler, Marlies; Michel, Kilian; Marrazzo, Livia; Obenland, Michael; Pallotta, Stefania; Björnsgard, Mari; Lutterbach, Johannes
2017-09-01
The purpose of this study was to characterize a new single large-area ionization chamber, the integral quality monitor system (iRT, Germany), for online and real-time beam monitoring. Signal stability, monitor unit (MU) linearity and dose rate dependence were investigated for static and arc deliveries and compared to independent ionization chamber measurements. The dose verification capability of the transmission detector system was evaluated by comparing calculated and measured detector signals for 15 volumetric modulated arc therapy plans. The error detection sensitivity was tested by introducing MLC position and linac output errors. Deviations in dose distributions between the original and error-induced plans were compared in terms of detector signal deviation, dose-volume histogram (DVH) metrics and 2D γ-evaluation (2%/2 mm and 3%/3 mm). The detector signal is linearly dependent on linac output and shows negligible (<0.4%) dose rate dependence up to 460 MU min-1. Signal stability is within 1% for cumulative detector output; substantial variations were observed for the segment-by-segment signal. Calculated versus measured cumulative signal deviations ranged from -0.16%-2.25%. DVH, mean 2D γ-value and detector signal evaluations showed increasing deviations with regard to the respective reference with growing MLC and dose output errors; good correlation between DVH metrics and detector signal deviation was found (e.g. PTV D mean: R 2 = 0.97). Positional MLC errors of 1 mm and errors in linac output of 2% were identified with the transmission detector system. The extensive tests performed in this investigation show that the new transmission detector provides a stable and sensitive cumulative signal output and is suitable for beam monitoring during patient treatment.
Accuracy of Digitally Fabricated Wax Denture Bases and Conventional Completed Complete Dentures.
Stawarczyk, Bogna; Lümkemann, Nina; Eichberger, Marlis; Wimmer, Timea
2017-12-19
The purpose of this investigation was to analyze the accuracy of digitally fabricated wax trial dentures and conventionally finalized complete dentures in comparison to a surface tessellation language (STL)-dataset. A generated data set for the denture bases and the tooth sockets was used, converted into STL-format, and saved as reference. Five mandibular and 5 maxillary denture bases were milled from wax blanks and denture teeth were waxed into their tooth sockets. Each complete denture was checked on fit, waxed onto the dental cast, and digitized using an optical laboratory scanning device. The complete dentures were completed conventionally using the injection method, finished, and scanned. The resulting STL-datasets were exported into the three-dimensional (3D) software GOM Inspect. Each of the 5 mandibular and 5 maxillary complete dentures was aligned with the STL- and the wax trial denture dataset. Alignment was performed based on a best-fit algorithm. A three-dimensional analysis of the spatial divergences in x -, y - and z -axes was performed by the 3D software and visualized in a color-coded illustration. The mean positive and negative deviations between the datasets were calculated automatically. In a direct comparison between maxillary wax trial dentures and complete dentures, complete dentures showed higher deviations from the STL-dataset than the wax trial dentures. The deviations occurred in the area of the teeth as well as in the distal area of the denture bases. In contrast, the highest deviations in both the mandibular wax trial dentures and the mandibular complete dentures were observed in the distal area. The complete dentures showed higher deviations on the occlusal surfaces of the teeth compared to the wax dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated wax dentures exhibited fewer deviations from the STL-reference than the complete dentures. The deviations were significantly greater in the vicinity of the denture teeth area and the bases. The conventional transfer of CAD/CAM-fabricated wax dentures into acrylic resin leads to the highest deviations from the STL-reference.
Method of surface error visualization using laser 3D projection technology
NASA Astrophysics Data System (ADS)
Guo, Lili; Li, Lijuan; Lin, Xuezhu
2017-10-01
In the process of manufacturing large components, such as aerospace, automobile and shipping industry, some important mold or stamped metal plate requires precise forming on the surface, which usually needs to be verified, if necessary, the surface needs to be corrected and reprocessed. In order to make the correction of the machined surface more convenient, this paper proposes a method based on Laser 3D projection system, this method uses the contour form of terrain contour, directly showing the deviation between the actually measured data and the theoretical mathematical model (CAD) on the measured surface. First, measure the machined surface to get the point cloud data and the formation of triangular mesh; secondly, through coordinate transformation, unify the point cloud data to the theoretical model and calculate the three-dimensional deviation, according to the sign (positive or negative) and size of the deviation, use the color deviation band to denote the deviation of three-dimensional; then, use three-dimensional contour lines to draw and represent every coordinates deviation band, creating the projection files; finally, import the projection files into the laser projector, and make the contour line projected to the processed file with 1:1 in the form of a laser beam, compare the Full-color 3D deviation map with the projection graph, then, locate and make quantitative correction to meet the processing precision requirements. It can display the trend of the machined surface deviation clearly.
Human influences on streamflow drought characteristics in England and Wales
NASA Astrophysics Data System (ADS)
Tijdeman, Erik; Hannaford, Jamie; Stahl, Kerstin
2018-02-01
Human influences can affect streamflow drought characteristics and propagation. The question is where, when and why? To answer these questions, the impact of different human influences on streamflow droughts were assessed in England and Wales, across a broad range of climate and catchments conditions. We used a dataset consisting of catchments with near-natural flow as well as catchments for which different human influences have been indicated in the metadata (Factors Affecting Runoff
) of the UK National River Flow Archive (NRFA). A screening approach was applied on the streamflow records to identify human-influenced records with drought characteristics that deviated from those found for catchments with near-natural flow. Three different deviations were considered, specifically deviations in (1) the relationship between streamflow drought duration and the base flow index, BFI (specifically, BFIHOST, the BFI predicted from the hydrological properties of soils), (2) the correlation between streamflow and precipitation and (3) the temporal occurrence of streamflow droughts compared to precipitation droughts, i.e. an increase or decrease in streamflow drought months relative to precipitation drought months over the period of record. The identified deviations were then related to the indicated human influences. Results showed that the majority of catchments for which human influences were indicated did not show streamflow drought characteristics that deviated from those expected under near-natural conditions. For the catchments that did show deviating streamflow drought characteristics, prolonged streamflow drought durations were found in some of the catchments affected by groundwater abstractions. Weaker correlations between streamflow and precipitation were found for some of the catchments with reservoirs, water transfers or groundwater augmentation schemes. An increase in streamflow drought occurrence towards the end of their records was found for some of the catchments affected by groundwater abstractions and a decrease in streamflow drought occurrence for some of the catchments with either reservoirs or groundwater abstractions. In conclusion, the proposed screening approaches were sometimes successful in identifying streamflow records with deviating drought characteristics that are likely related to different human influences. However, a quantitative attribution of the impact of human influences on streamflow drought characteristics requires more detailed case-by-case information about the type and degree of all different human influences. Given that, in many countries, such information is often not readily accessible, the approaches adopted here could provide useful in targeting future efforts. In England and Wales specifically, the catchments with deviating streamflow drought characteristics identified in this study could serve as the starting point of detailed case study research.
Khalil, E; Najjar, S; Sallam, A
2000-04-01
Aqueous solubility of diclofenac diethylamine (DDEA), a nonsteroidal anti-inflammatory drug currently formulated as a topical emulgel, was studied in the presence of pharmaceutical additives and compared with diclofenac sodium (DS). Electrolytes at low concentrations exhibited a salting-in effect on DDEA with peak solubility that was attributed to the association of DDEA into micelles, followed by a salting-out effect at higher concentrations, by which structure formation by DDEA molecules increased and precipitation occurred. For DS, which is not capable of forming micelles, the salting-out effect was dominant due to the common ion effect. Cosolvents displayed significant enhancement in solubility of both salts except glycerol, which showed a slight increase in solubility of DDEA and a decrease in solubility of DS due to transformation into the less soluble hydrate form. Ethanol and polyethylene glycol (PEG) 400 cosolvent systems at all concentrations showed positive deviations from the log-linear solubility equation. In the case of propylene glycol (PG) cosolvent systems, negative deviations were observed at low volume fractions of cosolvent, while positive deviations were observed at high volume fractions of cosolvent for DS and DDEA. The parent drug, being less ionizable and highly nonpolar, showed negative deviations up to 90% PG content. Thus, the positive deviations for DS and DDEA could be attributed to the more ionizable carboxylic group and its higher ability for hydrogen bonding at higher fractions of cosolvent. Polyvinylpyrrolidone (PVP) and PEG4000 or PEG6000 enhanced the solubility of DS and DDEA, with PVP exerting higher solubilizing efficiency and DS showing better solubility than DDEA. Solubilities of DS in Tween 80 (T80) and Pluronic F-127 (PF127) aqueous solutions were almost similar, while the solubility of DDEA in the presence of T80 was higher than the solubility in the presence of PF127. DS appeared to be located more in the polyoxyethylene mantle of the micelles, while DDEA was located more in the core of the micelles.
Lin, Yifan; Chen, Gui; Fu, Zhen; Ma, Lian; Li, Weiran
2015-01-01
To evaluate, using cone-beam computed tomography (CBCT), both the condylar-fossa relationships and the mandibular and condylar asymmetries between unilateral cleft lip and palate (UCLP) patients and non-cleft patients with class III skeletal relationship, and to investigate the factors of asymmetry contributing to chin deviation. The UCLP and non-cleft groups consisted of 30 and 40 subjects, respectively, in mixed dentition with class III skeletal relationships. Condylar-fossa relationships and the dimensional and positional asymmetries of the condyles and mandibles were examined using CBCT. Intra-group differences were compared between two sides in both groups using a paired t-test. Furthermore, correlations between each measurement and chin deviation were assessed. It was observed that 90% of UCLP and 67.5% of non-cleft subjects had both condyles centered, and no significant asymmetry was found. The axial angle and the condylar center distances to the midsagittal plane were significantly greater on the cleft side than on the non-cleft side (P=0.001 and P=0.028, respectively) and were positively correlated with chin deviation in the UCLP group. Except for a larger gonial angle on the cleft side, the two groups presented with consistent asymmetries showing shorter mandibular bodies and total mandibular lengths on the cleft (deviated) side. The average chin deviation was 1.63 mm to the cleft side, and the average absolute chin deviation was significantly greater in the UCLP group than in the non-cleft group (P=0.037). Compared with non-cleft subjects with similar class III skeletal relationships, the subjects with UCLP showed more severe lower facial asymmetry. The subjects with UCLP presented with more asymmetrical positions and rotations of the condyles on axial slices, which were positively correlated with chin deviation.
Zhang, Lin; Li, Xiue; Yan, Hong; Huang, Lei
2018-01-01
Salivary matrix metalloproteinase (MMP)-8 is currently considered to be one of the most promising biomarkers for early diagnosis of periodontitis, however, several recent studies showed conflicting results. To determine the salivary matrix metalloproteinase (MMP)-8 levels between periodontitis patients and healthy individuals, and to assess its diagnostic value in periodontitis. Literatures were searched on PubMed and Embase databases up to August 2017, for articles reporting salivary MMP-8 levels between periodontitis patients and health controls with the data of means ± standard deviation (SD). Methodological quality was assessed by the Newcastle Ottawa scale (NOS). Standard mean differences (SMDs), heterogeneity, and publication bias were assessed by Stata 13.0 software. A total of 10 studies including 485 periodontitis patients and 379 healthy controls that met the preset inclusion criteria were included, the qualities of these studies were either good (n = 7) or moderate (n = 3). Eight studies showed salivary MMP-8 levels were higher in periodontitis patients compared with healthy controls (P < .05), while 2 studies showed opposite results (P > .05). The pooled SMD was 1.195 (95% CI: 0.720-1.670), with I of 89.3%, indicating high heterogeneity. Funnel plot showed publication bias existed. Our meta-analysis showed that salivary MMP-8 levels were significantly higher in periodontitis patients compared with healthy controls overall. Due to the heterogeneity and publication bias of included studies, further high quality studies are still needed to verify the conclusion. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Dong; Campos, Edwin; Liu, Yangang
2014-09-01
Statistical characteristics of cloud variability are examined for their dependence on averaging scales and best representation of probability density function with the decade-long retrieval products of cloud liquid water path (LWP) from the tropical western Pacific (TWP), Southern Great Plains (SGP), and North Slope of Alaska (NSA) sites of the Department of Energy's Atmospheric Radiation Measurement Program. The statistical moments of LWP show some seasonal variation at the SGP and NSA sites but not much at the TWP site. It is found that the standard deviation, relative dispersion (the ratio of the standard deviation to the mean), and skewness all quickly increase with the averaging window size when the window size is small and become more or less flat when the window size exceeds 12 h. On average, the cloud LWP at the TWP site has the largest values of standard deviation, relative dispersion, and skewness, whereas the NSA site exhibits the least. Correlation analysis shows that there is a positive correlation between the mean LWP and the standard deviation. The skewness is found to be closely related to the relative dispersion with a correlation coefficient of 0.6. The comparison further shows that the lognormal, Weibull, and gamma distributions reasonably explain the observed relationship between skewness and relative dispersion over a wide range of scales.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Dong; Campos, Edwin; Liu, Yangang
2014-09-17
Statistical characteristics of cloud variability are examined for their dependence on averaging scales and best representation of probability density function with the decade-long retrieval products of cloud liquid water path (LWP) from the tropical western Pacific (TWP), Southern Great Plains (SGP), and North Slope of Alaska (NSA) sites of the Department of Energy’s Atmospheric Radiation Measurement Program. The statistical moments of LWP show some seasonal variation at the SGP and NSA sites but not much at the TWP site. It is found that the standard deviation, relative dispersion (the ratio of the standard deviation to the mean), and skewness allmore » quickly increase with the averaging window size when the window size is small and become more or less flat when the window size exceeds 12 h. On average, the cloud LWP at the TWP site has the largest values of standard deviation, relative dispersion, and skewness, whereas the NSA site exhibits the least. Correlation analysis shows that there is a positive correlation between the mean LWP and the standard deviation. The skewness is found to be closely related to the relative dispersion with a correlation coefficient of 0.6. The comparison further shows that the log normal, Weibull, and gamma distributions reasonably explain the observed relationship between skewness and relative dispersion over a wide range of scales.« less
NASA Astrophysics Data System (ADS)
Qian, Shinan; Geckeler, Ralf D.; Just, Andreas; Idir, Mourad; Wu, Xuehui
2015-06-01
Since the development of the Nano-Optic-Measuring Machine (NOM), the accuracy of measuring the profile of an optical surface has been enhanced to the 100-nrad rms level or better. However, to update the accuracy of the NOM system to sub-50 nrad rms, the large saw-tooth deviation (269 nrad rms) of an existing electronic autocollimator, the Elcomat 3000/8, must be resolved. We carried out simulations to assess the saw-tooth-like deviation. We developed a method for setting readings to reduce the deviation to sub-50 nrad rms, suitable for testing plane mirrors. With this method, we found that all the tests conducted in a slowly rising section of the saw-tooth show a small deviation of 28.8 to <40 nrad rms. We also developed a dense-measurement method and an integer-period method to lower the saw-tooth deviation during tests of sphere mirrors. Further research is necessary for formulating a precise test for a spherical mirror. We present a series of test results from our experiments that verify the value of the improvements we made.
Frisén, Lars
2010-12-01
Deviations of the subjective visual vertical in the roll or fronto-parallel plane occur commonly in disorders of the brainstem and have been extensively explored. In contrast, little is known about deviations in other directions. The present retrospective study focused on deviations in the pitch (sagittal) direction in 176 patients with a wide variety of disorders. The test task was to set a self-illuminated rod in the apparent upright position, in total darkness. Abnormal results (outside ± 4°) were recorded in 58% of the subjects. Negative (top backward) deviations were the most common, particularly with mass lesions in the pineal region, obstructive hydrocephalus, cerebellar lesions and crowding at the craniocervical junction. Positive and negative deviations were about equally common with focal intra-axial lesions. Negative deviations appeared related to dorsal locations of lesions and vice versa. Normal pressure hydrocephalus, Parkinson's disease and progressive supranuclear palsy were associated with smaller deviations, without a clear directional preponderance, and a larger individual variability. Most subjects lacked overt clinical corollaries. The most common ocular signs were aqueduct syndromes (n = 17) and ocular tilt reactions (n = 12), which were associated with deviations in 47 and 92% of instances, respectively. Subjective corollaries of deviation were never reported, not even by those subjects who showed a dramatic improvement upon resolution of the underlying condition. Deviations were also assessed in roll in a subgroup of 40 patients with focal lesions. Thirty subjects returned abnormal results: 13% in roll, 47% in pitch and 40% in pitch and roll. The direction of roll deviation appeared primarily related to laterality, with clockwise deviations with right-sided lesions and vice versa. All subjects with ocular tilt reactions had combined pitch and roll deviations, implying a common neural substrate. Correlation analyses, geometrical modelling and experimental self-observations indicated that deviations in pitch were attributable to cyclotorsional asymmetries between the eyes. The frequent co-existence of abnormal pitch and roll results implies that the true axis of deviation in focal brainstem disorders commonly falls outside traditional reference planes. The term 'visual upright in three dimensions' is suggested to identify unrestricted measurements, preserving the established term 'visual vertical' for measurements confined to the roll plane. Assessment of the visual upright in three dimensions provides a new, quantitative angle on brainstem disorders. The test appears useful for identifying a ubiquitous yet clinically silent feature of brainstem disease and also for monitoring the evolution of underlying conditions. More detailed explorations appear well motivated.
A finite element algorithm for high-lying eigenvalues with Neumann and Dirichlet boundary conditions
NASA Astrophysics Data System (ADS)
Báez, G.; Méndez-Sánchez, R. A.; Leyvraz, F.; Seligman, T. H.
2014-01-01
We present a finite element algorithm that computes eigenvalues and eigenfunctions of the Laplace operator for two-dimensional problems with homogeneous Neumann or Dirichlet boundary conditions, or combinations of either for different parts of the boundary. We use an inverse power plus Gauss-Seidel algorithm to solve the generalized eigenvalue problem. For Neumann boundary conditions the method is much more efficient than the equivalent finite difference algorithm. We checked the algorithm by comparing the cumulative level density of the spectrum obtained numerically with the theoretical prediction given by the Weyl formula. We found a systematic deviation due to the discretization, not to the algorithm itself.
NASA Technical Reports Server (NTRS)
Connor, Charles B.; Stoiber, Richard E.; Malinconico, Lawrence L., Jr.
1988-01-01
Variation in SO2 emissions from Halemaumau crater, Kilauea volcano, Hawaii is analyzed using a set of techniques known as exploratory data analysis. SO2 flux was monitored using a correlation spectrometer. A total of 302 measurements were made on 73 days over a 90-day period. The mean flux was 171 t/d with a standard deviation of 52 t/d. A significant increase in flux occurs during increased seismic activity beneath the caldera. SO2 flux prior to this change varies in a systematic way and may be related to variation in the tidal modulation envelope.
Methodology for evaluating pattern transfer completeness in inkjet printing with irregular edges
NASA Astrophysics Data System (ADS)
Huang, Bo-Cin; Chan, Hui-Ju; Hong, Jian-Wei; Lo, Cheng-Yao
2016-06-01
A methodology for quantifying and qualifying pattern transfer completeness in inkjet printing through examining both pattern dimensions and pattern contour deviations from reference design is proposed, which enables scientifically identifying and evaluating inkjet-printed lines, corners, circles, ellipses, and spirals with irregular edges of bulging, necking, and unpredictable distortions resulting from different process conditions. This methodology not only avoids differences in individual perceptions of ambiguous pattern distortions but also indicates the systematic effects of mechanical stresses applied in different directions to a polymer substrate, and is effective for both optical and electrical microscopy in direct and indirect lithography or lithography-free patterning.
Patra, Goutam Kumar; Mukherjee, Anindita; Ng, Seik Weng
2009-01-01
The title compound (systematic name: 1,1′,2,2′-tetraphenyl-2,2′-azinodiethanone), C28H20N2O2, was obtained by the reaction of benzil monohydrazone with chromium(III) nitrate. The dibenzylidene hydrazine unit is nearly planar (r.m.s. deviation = 0.073 Å) and the two benzoyl units are oriented almost perpendicular to it [dihedral angle = 87.81 (2), 87.81 (2)°]. The molecules are linked into chains along the c axis by C—H⋯O hydrogen bonds and the chains are cross-linked via C—H⋯π interactions involving the benzoyl phenyl rings. PMID:21583456
What Children Recall about a Repeated Event When One Instance Is Different from the Others
ERIC Educational Resources Information Center
Connolly, Deborah A.; Gordon, Heidi M.; Woiwod, Dayna M.; Price, Heather L.
2016-01-01
This research examined whether a memorable and unexpected change (deviation details) presented during 1 instance of a repeated event facilitated children's memory for that instance and whether a repeated event facilitated children's memory for deviation details. In Experiments 1 and 2, 8-year-olds (N = 167) watched 1 or 4 live magic shows.…
On the Linear Relation between the Mean and the Standard Deviation of a Response Time Distribution
ERIC Educational Resources Information Center
Wagenmakers, Eric-Jan; Brown, Scott
2007-01-01
Although it is generally accepted that the spread of a response time (RT) distribution increases with the mean, the precise nature of this relation remains relatively unexplored. The authors show that in several descriptive RT distributions, the standard deviation increases linearly with the mean. Results from a wide range of tasks from different…
Mancia, G; Ferrari, A; Gregorini, L; Parati, G; Pomidossi, G; Bertinieri, G; Grassi, G; Zanchetti, A
1980-12-01
1. Intra-arterial blood pressure and heart rate were recorded for 24 h in ambulant hospitalized patients of variable age who had normal blood pressure or essential hypertension. Mean 24 h values, standard deviations and variation coefficient were obtained as the averages of values separately analysed for 48 consecutive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation aations and variation coefficient were obtained as the averages of values separately analysed for 48 consecurive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for heart rate were smaller. 3. In hypertensive subjects standard deviation for mean arterial pressure was greater than in normotensive subjects of similar ages, but this was not the case for variation coefficient, which was slightly smaller in the former than in the latter group. Normotensive and hypertensive subjects showed no difference in standard deviation and variation coefficient for heart rate. 4. In both normotensive and hypertensive subjects standard deviation and even more so variation coefficient were slightly or not related to arterial baroreflex sensitivity as measured by various methods (phenylephrine, neck suction etc.). 5. It is concluded that blood pressure variability increases and heart rate variability decreases with age, but that changes in variability are not so obvious in hypertension. Also, differences in variability among subjects are only marginally explained by differences in baroreflex function.
Han, Zhifeng; Liu, Jianye; Li, Rongbing; Zeng, Qinghua; Wang, Yi
2017-07-04
BeiDou system navigation messages are modulated with a secondary NH (Neumann-Hoffman) code of 1 kbps, where frequent bit transitions limit the coherent integration time to 1 millisecond. Therefore, a bit synchronization algorithm is necessary to obtain bit edges and NH code phases. In order to realize bit synchronization for BeiDou weak signals with large frequency deviation, a bit synchronization algorithm based on differential coherent and maximum likelihood is proposed. Firstly, a differential coherent approach is used to remove the effect of frequency deviation, and the differential delay time is set to be a multiple of bit cycle to remove the influence of NH code. Secondly, the maximum likelihood function detection is used to improve the detection probability of weak signals. Finally, Monte Carlo simulations are conducted to analyze the detection performance of the proposed algorithm compared with a traditional algorithm under the CN0s of 20~40 dB-Hz and different frequency deviations. The results show that the proposed algorithm outperforms the traditional method with a frequency deviation of 50 Hz. This algorithm can remove the effect of BeiDou NH code effectively and weaken the influence of frequency deviation. To confirm the feasibility of the proposed algorithm, real data tests are conducted. The proposed algorithm is suitable for BeiDou weak signal bit synchronization with large frequency deviation.
ERP correlates of unexpected word forms in a picture–word study of infants and adults
Duta, M.D.; Styles, S.J.; Plunkett, K.
2012-01-01
We tested 14-month-olds and adults in an event-related potentials (ERPs) study in which pictures of familiar objects generated expectations about upcoming word forms. Expected word forms labelled the picture (word condition), while unexpected word forms mismatched by either a small deviation in word medial vowel height (mispronunciation condition) or a large deviation from the onset of the first speech segment (pseudoword condition). Both infants and adults showed sensitivity to both types of unexpected word form. Adults showed a chain of discrete effects: positivity over the N1 wave, negativity over the P2 wave (PMN effect) and negativity over the N2 wave (N400 effect). Infants showed a similar pattern, including a robust effect similar to the adult P2 effect. These observations were underpinned by a novel visualisation method which shows the dynamics of the ERP within bands of the scalp over time. The results demonstrate shared processing mechanisms across development, as even subtle deviations from expected word forms were indexed in both age groups by a reduction in the amplitude of characteristic waves in the early auditory evoked potential. PMID:22483072
Systematic approach in Mg2+ ions analysis with a combination of tailored fluorophore design.
Lvova, L; Guanais Gonçalves, C; Prodi, L; Sgarzi, M; Zaccheroni, N; Lombardo, M; Legin, A; Di Natale, C; Paolesse, R
2017-10-02
A systematic study of a series of diaza-18-crown-6 8-hydroxyquinoline (DCHQ) chemosensors, devoted to Mg(II) ion detection, was performed. Functionalization of DCHQ by peripheral substituents allowed the development of novel all-solid-state optodes via inclusion inside PVC-based polymeric films. The influence on the DCHQ-based optode response of the lipophilic sites functionalization and of the nature of the plasticizer, was investigated. Fluorimetric studies on optodes sensitivity towards a number of different metal cations (Ca 2+ , Na + , K + , Li + , Co 2+ , Cd 2+ , Pb 2+ , Cu 2+ , Hg 2+ , Zn 2+ ) and NH 4 + were carried out. The results demonstrated the suitability of the DCHQ optodes to perform fast monitoring (<10s) of magnesium (II) ions. Emission light signal was sufficiently brilliant to be captured by a low-cost computer webcam. The phenyl-substituted DCHQ-Ph derivative showed the best performance with a wide range for Mg(II) ion determination between 2.7 × 10 -7 and 2.2 × 10 -2 mol/L. It was possible, therefore, to determine the concentrations of Mg(II) in commercial fertilizer samples by DCHQ-Ph-based optodes with acceptable results: recoveries of 96.2-104.9% and relative standard deviation (RSD, n = 6) less than 5%. Moreover, in comparison to single sensors, the use of an array composed of five optodes (the ones showing the best performances in the preliminary tests) has allowed to reduce the RSD of magnesium determination in real samples (down to 3.7% with respect to 5.5% for single optodes) and to achieve a detection limit (estimated by s/n = 3 method) as low as 4.6 × 10 -7 mol/L. Copyright © 2017 Elsevier B.V. All rights reserved.
VLBI-derived troposphere parameters during CONT08
NASA Astrophysics Data System (ADS)
Heinkelmann, R.; Böhm, J.; Bolotin, S.; Engelhardt, G.; Haas, R.; Lanotte, R.; MacMillan, D. S.; Negusini, M.; Skurikhina, E.; Titov, O.; Schuh, H.
2011-07-01
Time-series of zenith wet and total troposphere delays as well as north and east gradients are compared, and zenith total delays ( ZTD) are combined on the level of parameter estimates. Input data sets are provided by ten Analysis Centers (ACs) of the International VLBI Service for Geodesy and Astrometry (IVS) for the CONT08 campaign (12-26 August 2008). The inconsistent usage of meteorological data and models, such as mapping functions, causes systematics among the ACs, and differing parameterizations and constraints add noise to the troposphere parameter estimates. The empirical standard deviation of ZTD among the ACs with regard to an unweighted mean is 4.6 mm. The ratio of the analysis noise to the observation noise assessed by the operator/software impact (OSI) model is about 2.5. These and other effects have to be accounted for to improve the intra-technique combination of VLBI-derived troposphere parameters. While the largest systematics caused by inconsistent usage of meteorological data can be avoided and the application of different mapping functions can be considered by applying empirical corrections, the noise has to be modeled in the stochastic model of intra-technique combination. The application of different stochastic models shows no significant effects on the combined parameters but results in different mean formal errors: the mean formal errors of the combined ZTD are 2.3 mm (unweighted), 4.4 mm (diagonal), 8.6 mm [variance component (VC) estimation], and 8.6 mm (operator/software impact, OSI). On the one hand, the OSI model, i.e. the inclusion of off-diagonal elements in the cofactor-matrix, considers the reapplication of observations yielding a factor of about two for mean formal errors as compared to the diagonal approach. On the other hand, the combination based on VC estimation shows large differences among the VCs and exhibits a comparable scaling of formal errors. Thus, for the combination of troposphere parameters a combination of the two extensions of the stochastic model is recommended.
Keles, Ali; Keskin, Cangül
2018-06-01
The present study aimed to quantitatively analyze apical foramen deviations of mesial root canals of mandibular first molar teeth by means of micro-computed tomographic (micro-CT) imaging. Micro-CT images of the mesial roots of 109 mandibular first molar teeth with independent mesiobuccal (MB) and mesiolingual (ML) root canals were analyzed. The deviations of the apical foramina of the MB, ML, and middle mesial root canals from the anatomic apex were measured. The vertical distance between the apical foramina of each mesial root canal in relation to each other was also calculated. The distances from the apical foramina of the MB, ML, and middle mesial root canals to the anatomic apex of the mesial root were up to 2.51 mm, 3.21 mm, and 5.67 mm, respectively. There was no significant difference between the deviations of MB and ML root canals from each other (P > .05). The middle mesial root canal showed the greatest deviation compared with the MB and ML canals (P < .05). The apical foramina of mesial root canals of mandibular first molar teeth showed greater variations from each other and anatomic apices than previously reported. Clinically, the use of electronic apex locators for the detection of minor apical foramen of each mesial root canal is of the utmost important. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Welding deviation detection algorithm based on extremum of molten pool image contour
NASA Astrophysics Data System (ADS)
Zou, Yong; Jiang, Lipei; Li, Yunhua; Xue, Long; Huang, Junfen; Huang, Jiqiang
2016-01-01
The welding deviation detection is the basis of robotic tracking welding, but the on-line real-time measurement of welding deviation is still not well solved by the existing methods. There is plenty of information in the gas metal arc welding(GMAW) molten pool images that is very important for the control of welding seam tracking. The physical meaning for the curvature extremum of molten pool contour is revealed by researching the molten pool images, that is, the deviation information points of welding wire center and the molten tip center are the maxima and the local maxima of the contour curvature, and the horizontal welding deviation is the position difference of these two extremum points. A new method of weld deviation detection is presented, including the process of preprocessing molten pool images, extracting and segmenting the contours, obtaining the contour extremum points, and calculating the welding deviation, etc. Extracting the contours is the premise, segmenting the contour lines is the foundation, and obtaining the contour extremum points is the key. The contour images can be extracted with the method of discrete dyadic wavelet transform, which is divided into two sub contours including welding wire and molten tip separately. The curvature value of each point of the two sub contour lines is calculated based on the approximate curvature formula of multi-points for plane curve, and the two points of the curvature extremum are the characteristics needed for the welding deviation calculation. The results of the tests and analyses show that the maximum error of the obtained on-line welding deviation is 2 pixels(0.16 mm), and the algorithm is stable enough to meet the requirements of the pipeline in real-time control at a speed of less than 500 mm/min. The method can be applied to the on-line automatic welding deviation detection.
NASA Astrophysics Data System (ADS)
Bertello, L.; Henney, C. J.; Ulrich, R. K.; Varadi, F.; Kosovichev, A. G.; Scherrer, P. H.; Cortés, T. Roca; Thiery, S.; Boumier, P.; Gabriel, A. H.; Turck-Chièze, S.
2000-06-01
During the years 1996 through 1998 the Michelson Doppler Imager (MDI) and the Global Oscillations at Low Frequency (GOLF) experiments on the Solar and Heliospheric Observatory (SOHO) mission have provided unique and nearly uninterrupted sequences of helioseismic observations. This paper describes the analysis carried out on power spectra from 759 days of calibrated disk-averaged velocity signals provided by these two experiments. The period investigated in this work is from 1996 May 25 to 1998 June 22. We report the results of frequency determination of low-degree (l<=3) acoustic modes in the frequency range between 1.4 mHz and 3.7 mHz. Rotational splittings are also measured for nonradial modes up to 3.0 mHz. The power spectrum estimation of the signals is performed using classical Fourier analysis and the line-profile parameters of the modes are determined by means of a maximum likelihood method. All parameters have been estimated using both symmetrical and asymmetrical line profile-fitting formula. The line asymmetry parameter of all modes with frequency higher than 2.0 mHz is systematically negative and independent of l. This result is consistent with the fact that both MDI and GOLF data sets investigated in this paper are predominantly velocity signals, in agreement with previous results. A comparison of the results between the symmetric and asymmetric fits shows that there is a systematic shift in the frequencies for modes above 2.0 mHz. Below this frequency, the line width of the modes is very small and the time base of the data does not provide enough statistics to reveal an asymmetry. In general, the results show that frequency and rotational splitting values obtained from both the MDI and GOLF signals are in excellent agreement, and no significant differences exist between the two data sets within the accuracy of the measurements. Our results are consistent with a uniform rotation of the solar core at the rate of about 435 nHz and show only very small deviations of the core structure from the standard solar model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kawai, D; Takahashi, R; Kamima, T
Purpose: Actual irradiated prescription dose to patients cannot be verified. Thus, independent dose verification and second treatment planning system are used as the secondary check. AAA dose calculation engine has contributed to lung SBRT. We conducted a multi-institutional study to assess variation of prescription dose for lung SBRT when using AAA in reference to using Acuros XB and Clarkson algorithm. Methods: Six institutes in Japan participated in this study. All SBRT treatments were planed using AAA in Eclipse and Adaptive Convolve (AC) in Pinnacle3. All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU,more » Triangle Product, Ishikawa, Japan), which implemented a Clarkson-based dose calculation algorithm using CT image dataset. A retrospective analysis for lung SBRT plans (73 patients) was performed to compute the confidence limit (CL, Average±2SD) in dose between the AAA and the SMU. In one of the institutes, a additional analysis was conducted to evaluate the variations between the AAA and the Acuros XB (AXB). Results: The CL for SMU shows larger systematic and random errors of 8.7±9.9 % for AAA than the errors of 5.7±4.2 % for AC. The variations of AAA correlated with the mean CT values in the voxels of PTV (a correlation coefficient : −0.7) . The comparison of AXB vs. AAA shows smaller systematic and random errors of −0.7±1.7%. The correlation between dose variations for AXB and the mean CT values in PTV was weak (0.4). However, there were several plans with more than 2% deviation of AAPM TG114 (Maximum: −3.3 %). Conclusion: In comparison for AC, prescription dose calculated by AAA may be more variable in lung SBRT patient. Even AXB comparison shows unexpected variation. Care should be taken for the use of AAA in lung SBRT. This research is partially supported by Japan Agency for Medical Research and Development (AMED)« less
NASA Astrophysics Data System (ADS)
McKay, N.
2017-12-01
As timescale increases from years to centuries, the spatial scale of covariability in the climate system is hypothesized to increase as well. Covarying spatial scales are larger for temperature than for hydroclimate, however, both aspects of the climate system show systematic changes on large-spatial scales on orbital to tectonic timescales. The extent to which this phenomenon is evident in temperature and hydroclimate at centennial timescales is largely unknown. Recent syntheses of multidecadal to century-scale variability in hydroclimate during the past 2k in the Arctic, North America, and Australasia show little spatial covariability in hydroclimate during the Common Era. To determine 1) the evidence for systematic relationships between the spatial scale of climate covariability as a function of timescale, and 2) whether century-scale hydroclimate variability deviates from the relationship between spatial covariability and timescale, we quantify this phenomenon during the Common Era by calculating the e-folding distance in large instrumental and paleoclimate datasets. We calculate this metric of spatial covariability, at different timescales (1, 10 and 100-yr), for a large network of temperature and precipitation observations from the Global Historical Climatology Network (n=2447), from v2.0.0 of the PAGES2k temperature database (n=692), and from moisture-sensitive paleoclimate records North America, the Arctic, and the Iso2k project (n = 328). Initial results support the hypothesis that the spatial scale of covariability is larger for temperature, than for precipitation or paleoclimate hydroclimate indicators. Spatially, e-folding distances for temperature are largest at low latitudes and over the ocean. Both instrumental and proxy temperature data show clear evidence for increasing spatial extent as a function of timescale, but this phenomenon is very weak in the hydroclimate data analyzed here. In the proxy hydroclimate data, which are predominantly indicators of effective moisture, e-folding distance increases from annual to decadal timescales, but does not continue to increase to centennial timescales. Future work includes examining additional instrumental and proxy datasets of moisture variability, and extending the analysis to millennial timescales of variability.
Hajizadeh, Maryam; Hashemi Oskouei, Alireza; Ghalichi, Farzan; Sole, Gisela
2016-06-01
Biomechanical changes have been reported for patients with anterior cruciate ligament deficiency (ACLD) and anterior cruciate ligament (ACL reconstruction) (ACLR), likely due to loss of stability and changes in proprioception and neuromotor control. This review evaluated kinematics and kinetics of ACLD and ACLR knees, compared with those on the contralateral uninjured sides, as well as and those in asymptomatic controls during stair navigation. This is a systematic review and meta-analysis. Electronic database searches were conducted from their original available dates to January 2015. Studies that included participants with ACLD or ACLR and reported knee joint angles or moments during stair ascent or descent were included. Nine studies met the inclusion criteria, and the methodological quality of these was assessed with a modified Downs and Black checklist. Effect sizes for differences between injured leg and uninjured contralateral leg or controls were calculated, and meta-analyses were performed if two or more studies considered the same variable. Quality assessment showed an average (± standard deviation) of 70.3% ± 7.2%. Meta-analysis showed less knee flexion at initial contact for ACLR knees compared with that in contralateral knees during stair ascent, with a moderate effect size and minimal heterogeneity. Knees with ACLD showed less peak knee flexion compared with that on contralateral sides during stair ascent, with minimal heterogeneity. External knee flexion moments were lower for ACLR compared with those in controls and contralateral sides during ascent and descent, whereas these moments were decreased for the ACLD compared with controls only during ascent. Meta-analysis results exhibited moderate/high heterogeneity or small/trivial effect sizes. Differences for kinematics and kinetics for the ACL-injured knees indicate long-term compensatory and asymmetric movement patterns while ascending and descending stairs. Due to the heterogeneity as well as the small numbers of available studies, the consequences of these differences in terms of long-term function or posttraumatic osteoarthritis need further exploration. Copyright © 2016. Published by Elsevier Inc.
On the Quality of Point-Clouds Derived from Sfm-Photogrammetry Applied to UAS Imagery
NASA Astrophysics Data System (ADS)
Carbonneau, P.; James, T.
2014-12-01
Structure from Motion photogrammetry (SfM-photogrammetry) recently appeared in environmental sciences as an impressive tool allowing for the creation of topographic data from unstructured imagery. Several authors have tested the performance of SfM-photogrammetry vs that of TLS or dGPS. Whilst the initial results were very promising, there is currently a growing awareness that systematic deformations occur in DEMs and point-clouds derived from SfM-photogrammetry. Notably, some authors have identified a systematic doming manifest as an increasing error vs distance to the model centre. Simulation studies have confirmed that this error is due to errors in the calibration of camera distortions. This work aims to further investigate these effects in the presence of real data. We start with a dataset of 220 images acquired from a sUAS. After obtaining an initial self-calibration of the camera lens with Agisoft Photoscan, our method consists in applying systematic perturbations to 2 key lens parameters: Focal length and the k1 distortion parameter. For each perturbation, a point-cloud was produced and compared to LiDAR data. After deriving the mean and standard deviation of the error residuals (ɛ), a 2nd order polynomial surface was fitted to the errors point-cloud and the peak ɛ defined as the mathematical extrema of this surface. The results are presented in figure 1. This figure shows that lens perturbations can induce a range of errors with systematic behaviours. Peak ɛ is primarily controlled by K1 with a secondary control exerted by the focal length. These results allow us to state that: To limit the peak ɛ to 10cm, the K1 parameter must be calibrated to within 0.00025 and the focal length to within 2.5 pixels (≈10 µm). This level of calibration accuracy can only be achieved with proper design of image acquisition and control network geometry. Our main point is therefore that SfM is not a bypass to a rigorous and well-informed photogrammetric approach. Users of SfM-photogrammetry will still require basic training and knowledge in the fundamentals of photogrammetry. This is especially true for applications where very small topographic changes need to be detected or where gradient-sensitive processes need to be modelled.
Diagnostics for insufficiencies of posterior calculations in Bayesian signal inference.
Dorn, Sebastian; Oppermann, Niels; Ensslin, Torsten A
2013-11-01
We present an error-diagnostic validation method for posterior distributions in Bayesian signal inference, an advancement of a previous work. It transfers deviations from the correct posterior into characteristic deviations from a uniform distribution of a quantity constructed for this purpose. We show that this method is able to reveal and discriminate several kinds of numerical and approximation errors, as well as their impact on the posterior distribution. For this we present four typical analytical examples of posteriors with incorrect variance, skewness, position of the maximum, or normalization. We show further how this test can be applied to multidimensional signals.
Houseknecht, D.W.; Bensley, D.F.; Hathon, L.A.; Kastens, P.H.
1993-01-01
Analysis and interpretation of dispersed vitrinite reflectance data in regions of high thermal maturity (> 2% vitrinite reflectance) have been equivocal partly because of an increase in width and complexity of reflectance histograms with increasing mean reflectance. Such complexity is illustrated by random reflectance (Rran) data from the Arkoma Basin that display a linear increase in standard deviation of Rran with an increase in mean Rran from 1 to 5%. Evaluating how much of the dispersion in these data is the result of vitrinite anisotropy and how much is the result of mixing of kerogen populations by sedimentary processes and/or sampling procedures has been problematic. Automated collection of reflectance data during polarizer rotation provides preliminary data for solution of this problem. Rotational reflectance data collected from a subset of Arkoma Basin samples reveal positive, linear relationships among maximum (R???max), random (Rran), rotational (Rrot), and minimum (R???min) reflectance, as well as a systematic increase in bireflectance (R???max-R???min) with increasing reflectance. R???max and Rrot display lower standard deviations and narrower, more nearly unimodal histograms than Rran and R???min, suggesting that R???max and Rrot are superior (less ambiguous) indices of thermal maturity. These data patterns are inferred to be mostly an indication of increasing vitrinite anisotropy with increasing thermal maturity, suggesting that the linear covariance observed between mean Rran and standard deviation in dispersed organic data sets from regions of high thermal maturity may be explained mostly as the result of increasing vitrinite anisotropy with increasing thermal maturity. ?? 1993.
Carrez, Laurent; Bouchoud, Lucie; Fleury-Souverain, Sandrine; Combescure, Christophe; Falaschi, Ludivine; Sadeghipour, Farshid; Bonnabry, Pascal
2017-03-01
Background and objectives Centralized chemotherapy preparation units have established systematic strategies to avoid errors. Our work aimed to evaluate the accuracy of manual preparations associated with different control methods. Method A simulation study in an operational setting used phenylephrine and lidocaine as markers. Each operator prepared syringes that were controlled using a different method during each of three sessions (no control, visual double-checking, and gravimetric control). Eight reconstitutions and dilutions were prepared in each session, with variable doses and volumes, using different concentrations of stock solutions. Results were analyzed according to qualitative (choice of stock solution) and quantitative criteria (accurate, <5% deviation from the target concentration; weakly accurate, 5%-10%; inaccurate, 10%-30%; wrong, >30% deviation). Results Eleven operators carried out 19 sessions. No final preparation (n = 438) contained a wrong drug. The protocol involving no control failed to detect 1 of 3 dose errors made and double-checking failed to detect 3 of 7 dose errors. The gravimetric control method detected all 5 out of 5 dose errors. The accuracy of the doses measured was equivalent across the control methods ( p = 0.63 Kruskal-Wallis). The final preparations ranged from 58% to 60% accurate, 25% to 27% weakly accurate, 14% to 17% inaccurate and 0.9% wrong. A high variability was observed between operators. Discussion Gravimetric control was the only method able to detect all dose errors, but it did not improve dose accuracy. A dose accuracy with <5% deviation cannot always be guaranteed using manual production. Automation should be considered in the future.
How humans use visual optic flow to regulate stepping during walking.
Salinas, Mandy M; Wilken, Jason M; Dingwell, Jonathan B
2017-09-01
Humans use visual optic flow to regulate average walking speed. Among many possible strategies available, healthy humans walking on motorized treadmills allow fluctuations in stride length (L n ) and stride time (T n ) to persist across multiple consecutive strides, but rapidly correct deviations in stride speed (S n =L n /T n ) at each successive stride, n. Several experiments verified this stepping strategy when participants walked with no optic flow. This study determined how removing or systematically altering optic flow influenced peoples' stride-to-stride stepping control strategies. Participants walked on a treadmill with a virtual reality (VR) scene projected onto a 3m tall, 180° semi-cylindrical screen in front of the treadmill. Five conditions were tested: blank screen ("BLANK"), static scene ("STATIC"), or moving scene with optic flow speed slower than ("SLOW"), matched to ("MATCH"), or faster than ("FAST") walking speed. Participants took shorter and faster strides and demonstrated increased stepping variability during the BLANK condition compared to the other conditions. Thus, when visual information was removed, individuals appeared to walk more cautiously. Optic flow influenced both how quickly humans corrected stride speed deviations and how successful they were at enacting this strategy to try to maintain approximately constant speed at each stride. These results were consistent with Weber's law: healthy adults more-rapidly corrected stride speed deviations in a no optic flow condition (the lower intensity stimuli) compared to contexts with non-zero optic flow. These results demonstrate how the temporal characteristics of optic flow influence ability to correct speed fluctuations during walking. Copyright © 2017 Elsevier B.V. All rights reserved.
Chaintreau, Alain; Fieber, Wolfgang; Sommer, Horst; Gilbert, Alexis; Yamada, Keita; Yoshida, Naohiro; Pagelot, Alain; Moskau, Detlef; Moreno, Aitor; Schleucher, Jürgen; Reniero, Fabiano; Holland, Margaret; Guillou, Claude; Silvestre, Virginie; Akoka, Serge; Remaud, Gérald S
2013-07-25
Isotopic (13)C NMR spectrometry, which is able to measure intra-molecular (13)C composition, is of emerging demand because of the new information provided by the (13)C site-specific content of a given molecule. A systematic evaluation of instrumental behaviour is of importance to envisage isotopic (13)C NMR as a routine tool. This paper describes the first collaborative study of intra-molecular (13)C composition by NMR. The main goals of the ring test were to establish intra- and inter-variability of the spectrometer response. Eight instruments with different configuration were retained for the exercise on the basis of a qualification test. Reproducibility at the natural abundance of isotopic (13)C NMR was then assessed on vanillin from three different origins associated with specific δ (13)Ci profiles. The standard deviation was, on average, between 0.9 and 1.2‰ for intra-variability. The highest standard deviation for inter-variability was 2.1‰. This is significantly higher than the internal precision but could be considered good in respect of a first ring test on a new analytical method. The standard deviation of δ (13)Ci in vanillin was not homogeneous over the eight carbons, with no trend either for the carbon position or for the configuration of the spectrometer. However, since the repeatability for each instrument was satisfactory, correction factors for each carbon in vanillin could be calculated to harmonize the results. Copyright © 2013 Elsevier B.V. All rights reserved.
A nonlinear generalization of the Savitzky-Golay filter and the quantitative analysis of saccades
Dai, Weiwei; Selesnick, Ivan; Rizzo, John-Ross; Rucker, Janet; Hudson, Todd
2017-01-01
The Savitzky-Golay (SG) filter is widely used to smooth and differentiate time series, especially biomedical data. However, time series that exhibit abrupt departures from their typical trends, such as sharp waves or steps, which are of physiological interest, tend to be oversmoothed by the SG filter. Hence, the SG filter tends to systematically underestimate physiological parameters in certain situations. This article proposes a generalization of the SG filter to more accurately track abrupt deviations in time series, leading to more accurate parameter estimates (e.g., peak velocity of saccadic eye movements). The proposed filtering methodology models a time series as the sum of two component time series: a low-frequency time series for which the conventional SG filter is well suited, and a second time series that exhibits instantaneous deviations (e.g., sharp waves, steps, or more generally, discontinuities in a higher order derivative). The generalized SG filter is then applied to the quantitative analysis of saccadic eye movements. It is demonstrated that (a) the conventional SG filter underestimates the peak velocity of saccades, especially those of small amplitude, and (b) the generalized SG filter estimates peak saccadic velocity more accurately than the conventional filter. PMID:28813566
Accuracy of the HST Standard Astrometric Catalogs w.r.t. Gaia
NASA Astrophysics Data System (ADS)
Kozhurina-Platais, V.; Grogin, N.; Sabbi, E.
2018-02-01
The goal of astrometric calibration of the HST ACS/WFC and WFC3/UVIS imaging instruments is to provide a coordinate system free of distortion to the precision level of 0.1 pixel 4-5 mas or better. This astrometric calibration is based on two HST astrometric standard fields in the vicinity of the globular clusters, 47 Tuc and omega Cen, respectively. The derived calibration of the geometric distortion is assumed to be accurate down to 2-3 mas. Is this accuracy in agreement with the true value? Now, with the access to globally accurate positions from the first Gaia data release (DR1), we found that there are measurable offsets, rotation, scale and other deviations of distortion parameters in two HST standard astrometric catalogs. These deviations from the distortion-free and properly aligned coordinate system should be accounted and corrected for, so that the high precision HST positions are free of any systematic errors. We also found that the precision of the HST pixel coordinates is substantially better than the accuracy listed in the Gaia DR1. Therefore, in order to finalize the components of distortion in the HST standard catalogs, the next release of Gaia data is needed.