Repeatability study of replicate crash tests: A signal analysis approach.
Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason
2017-10-03
To provide an objective basis on which to evaluate the repeatability of vehicle crash test methods, a recently developed signal analysis method was used to evaluate correlation of sensor time history data between replicate vehicle crash tests. The goal of this study was to evaluate the repeatability of rollover crash tests performed with the Dynamic Rollover Test System (DRoTS) relative to other vehicle crash test methods. Test data from DRoTS tests, deceleration rollover sled (DRS) tests, frontal crash tests, frontal offset crash tests, small overlap crash tests, small overlap impact (SOI) crash tests, and oblique crash tests were obtained from the literature and publicly available databases (the NHTSA vehicle database and the Insurance Institute for Highway Safety TechData) to examine crash test repeatability. Signal analysis of the DRoTS tests showed that force and deformation time histories had good to excellent repeatability, whereas vehicle kinematics showed only fair repeatability due to the vehicle mounting method for one pair of tests and slightly dissimilar mass properties (2.2%) in a second pair of tests. Relative to the DRS, the DRoTS tests showed very similar or higher levels of repeatability in nearly all vehicle kinematic data signals with the exception of global X' (road direction of travel) velocity and displacement due to the functionality of the DRoTS fixture. Based on the average overall scoring metric of the dominant acceleration, DRoTS was found to be as repeatable as all other crash tests analyzed. Vertical force measures showed good repeatability and were on par with frontal crash barrier forces. Dynamic deformation measures showed good to excellent repeatability as opposed to poor repeatability seen in SOI and oblique deformation measures. Using the signal analysis method as outlined in this article, the DRoTS was shown to have the same or better repeatability of crash test methods used in government regulatory and consumer evaluation test protocols.
de Oliveira, Anapolino Macedo; Fonseca, Antônio Augusto; Camargos, Marcelo Fernandes; Orzil, Lívia Maria; Laguardia-Nascimento, Mateus; Oliveira, Anna Gabriella Guimarães; Rodrigues, Jacqueline Gomes; Sales, Mariana Lázaro; de Oliveira, Tatiana Flávia Pinheiro; de Melo, Cristiano Barros
2018-07-01
Vesicular stomatitis is an infectious disease that occurs mainly in countries of the Western Hemisphere and affects cattle, swine and horses. The clinical symptoms in cattle and swine are similar to foot-and-mouth disease and include vesicular ulceration of the tongue and mouth. The disease requires a rapid and accurate differential diagnosis, aiming for immediate implementation of control measures. The objective of the present study was to develop and perform validation tests of multiplex RT-qPCR(s) for the detection of RNA from Alagoas vesiculovirus, considering the parameters of sensitivity and analytical specificity, analytical performance (repeatability and reproducibility criteria) and the uncertainty of the measurement. The threshold cycle values obtained in triplicate from each sample were evaluated by considering the variations between days, analysts and equipment in an analysis of variance aimed at determining the variances of repeatability and reproducibility. The results showed that RT-qPCRs had excellent sensitivity and specificity in the detection of RNA of the Alagoas vesiculovirus. The validation parameters showed low coefficients of variation and were equivalent to those found in other validation studies, indicating that the tests presented excellent repeatability and reproducibility. Copyright © 2018 Elsevier B.V. All rights reserved.
Fang, Danqi; Tang, Fang Yao; Huang, Haifan; Cheung, Carol Y; Chen, Haoyu
2018-05-29
To investigate the repeatability, interocular correlation and agreement of quantitative swept-source optical coherence tomography angiography (SS-OCTA) metrics in healthy subjects. Thirty-three healthy normal subjects were enrolled. The macula was scanned four times by an SS-OCTA system using the 3 mm×3 mm mode. The superficial capillary map images were analysed using a MATLAB program. A series of parameters were measured: foveal avascular zone (FAZ) area, FAZ perimeter, FAZ circularity, parafoveal vessel density, fractal dimension and vessel diameter index (VDI). The repeatability of four scans was determined by intraclass correlation coefficient (ICC). Then the averaged results were analysed for intereye difference, correlation and agreement using paired t-test, Pearson's correlation coefficient (r), ICC and Bland-Altman plot. The repeatability assessment of the macular metrics exported high ICC values (ranged from 0.853 to 0.996). There is no statistically significant difference in the OCTA metrics between the two eyes. FAZ area (ICC=0.961, r=0.929) and FAZ perimeter (ICC=0.884, r=0.802) showed excellent binocular correlation. Fractal dimension (ICC=0.732, r=0.578) and VDI (ICC=0.707, r=0.547) showed moderate binocular correlation, while parafoveal vessel density had poor binocular correlation. Bland-Altman plots showed the range of agreement was from -0.0763 to 0.0954 mm 2 for FAZ area and from -0.0491 to 0.1136 for parafoveal vessel density. The macular metrics obtained using SS-OCTA showed excellent repeatability in healthy subjects. We showed high intereye correlation in FAZ area and perimeter, moderate correlation in fractal dimension and VDI, while vessel density had poor correlation in normal healthy subjects. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Longo, F; Nicetto, T; Banzato, T; Savio, G; Drigo, M; Meneghello, R; Concheri, G; Isola, M
2018-02-01
The aim of this ex vivo study was to test a novel three-dimensional (3D) automated computer-aided design (CAD) method (aCAD) for the computation of femoral angles in dogs from 3D reconstructions of computed tomography (CT) images. The repeatability and reproducibility of three manual radiography, manual CT reconstructions and the aCAD method for the measurement of three femoral angles were evaluated: (1) anatomical lateral distal femoral angle (aLDFA); (2) femoral neck angle (FNA); and (3) femoral torsion angle (FTA). Femoral angles of 22 femurs obtained from 16 cadavers were measured by three blinded observers. Measurements were repeated three times by each observer for each diagnostic technique. Femoral angle measurements were analysed using a mixed effects linear model for repeated measures to determine the levels of intra-observer agreement (repeatability) and inter-observer agreement (reproducibility). Repeatability and reproducibility of measurements using the aCAD method were excellent (intra-class coefficients, ICCs≥0.98) for all three angles assessed. Manual radiography and CT exhibited excellent agreement for the aLDFA measurement (ICCs≥0.90). However, FNA repeatability and reproducibility were poor (ICCs<0.8), whereas FTA measurement showed slightly higher ICCs values, except for the radiographic reproducibility, which was poor (ICCs<0.8). The computation of the 3D aCAD method provided the highest repeatability and reproducibility among the tested methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.
When Do Individuals with Autism Spectrum Disorder Show Superiority in Visual Search?
ERIC Educational Resources Information Center
Shirama, Aya; Kato, Nobumasa; Kashino, Makio
2017-01-01
Although superior visual search skills have been repeatedly reported for individuals with autism spectrum disorder, the underlying mechanisms remain controversial. To specify the locus where individuals with autism spectrum disorder excel in visual search, we compared the performance of autism spectrum disorder adults and healthy controls in…
Ratiometric near infrared luminescent thermometer based on lanthanide metal-organic frameworks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yue, Dan; Zhang, Jun; Zhao, Dian
2016-09-15
A near infrared luminescent MOFs thermometer (Nd{sub 0.676}Yb{sub 0.324}BTC) was prepared via a simple solvothermal method using Ln{sup 3+} (Ln=Nd, Yb) ions and 1, 3, 5-benznenetricarboxylic acid (H{sub 3}BTC), and characterized by PXRD, TGA, ICP, and photoluminescence (PL) spectrum. These results indicate that the Nd{sub 0.676}Yb{sub 0.324}BTC displays high relative sensitivity and excellent repeatability in the physiological temperature range (288–323 K), and the maximum relative sensitivity is determined to be 1.187% K{sup −1} at 323 K. These NIR luminescent MOFs may have potential applications in physiological temperature sensing. - Graphical abstract: A near infrared luminescent MOFs thermometer (Nd{sub 0.054}Yb{sub 0.946}BTCmore » ) displays high relative sensitivity and excellent repeatability in the physiological temperature range (288–323 K). Display Omitted - Highlights: • A ratiometric near infrared luminescent MOFs thermometer (Nd{sub 0.676}Yb{sub 0.324}BTC) was prepared via a simple solvothermal method. • The maximum relative sensitivity of Nd{sub 0.676}Yb{sub 0.324}BTC is determined to be 1.187% K{sup −1} at 323 K. • Nd{sub 0.676}Yb{sub 0.324}BTC showed excellent repeatability in the physiological temperature range (288–323 K).« less
Omari, Taher I.; Savilampi, Johanna; Kokkinn, Karmen; Schar, Mistyka; Lamvik, Kristin; Doeltgen, Sebastian; Cock, Charles
2016-01-01
Purpose. We evaluated the intra- and interrater agreement and test-retest reliability of analyst derivation of swallow function variables based on repeated high resolution manometry with impedance measurements. Methods. Five subjects swallowed 10 × 10 mL saline on two occasions one week apart producing a database of 100 swallows. Swallows were repeat-analysed by six observers using software. Swallow variables were indicative of contractility, intrabolus pressure, and flow timing. Results. The average intraclass correlation coefficients (ICC) for intra- and interrater comparisons of all variable means showed substantial to excellent agreement (intrarater ICC 0.85–1.00; mean interrater ICC 0.77–1.00). Test-retest results were less reliable. ICC for test-retest comparisons ranged from slight to excellent depending on the class of variable. Contractility variables differed most in terms of test-retest reliability. Amongst contractility variables, UES basal pressure showed excellent test-retest agreement (mean ICC 0.94), measures of UES postrelaxation contractile pressure showed moderate to substantial test-retest agreement (mean Interrater ICC 0.47–0.67), and test-retest agreement of pharyngeal contractile pressure ranged from slight to substantial (mean Interrater ICC 0.15–0.61). Conclusions. Test-retest reliability of HRIM measures depends on the class of variable. Measures of bolus distension pressure and flow timing appear to be more test-retest reliable than measures of contractility. PMID:27190520
Kinematic repeatability of a multi-segment foot model for dance.
Carter, Sarah L; Sato, Nahoko; Hopper, Luke S
2018-03-01
The purpose of this study was to determine the intra and inter-assessor repeatability of a modified Rizzoli Foot Model for analysing the foot kinematics of ballet dancers. Six university-level ballet dancers performed the movements; parallel stance, turnout plié, turnout stance, turnout rise and flex-point-flex. The three-dimensional (3D) position of individual reflective markers and marker triads was used to model the movement of the dancers' tibia, entire foot, hindfoot, midfoot, forefoot and hallux. Intra and inter-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability for the first metatarsophalangeal joint in the sagittal plane. Intra-assessor reliability demonstrated excellent (ICC ≥ 0.75) repeatability during flex-point-flex across all inter-segmental angles except for the tibia-hindfoot and hindfoot-midfoot frontal planes. Inter-assessor repeatability ranged from poor to excellent (0.5 > ICC ≥ 0.75) for the 3D segment rotations. The most repeatable measure was the tibia-foot dorsiflexion/plantar flexion articulation whereas the least repeatable measure was the hindfoot-midfoot adduction/abduction articulation. The variation found in the inter-assessor results is likely due to inconsistencies in marker placement. This 3D dance specific multi-segment foot model provides insight into which kinematic measures can be reliably used to ascertain in vivo technical errors and/or biomechanical abnormalities in a dancer's foot motion.
Precision analysis of a quantitative CT liver surface nodularity score.
Smith, Andrew; Varney, Elliot; Zand, Kevin; Lewis, Tara; Sirous, Reza; York, James; Florez, Edward; Abou Elkassem, Asser; Howard-Claudio, Candace M; Roda, Manohar; Parker, Ellen; Scortegagna, Eduardo; Joyner, David; Sandlin, David; Newsome, Ashley; Brewster, Parker; Lirette, Seth T; Griswold, Michael
2018-04-26
To evaluate precision of a software-based liver surface nodularity (LSN) score derived from CT images. An anthropomorphic CT phantom was constructed with simulated liver containing smooth and nodular segments at the surface and simulated visceral and subcutaneous fat components. The phantom was scanned multiple times on a single CT scanner with adjustment of image acquisition and reconstruction parameters (N = 34) and on 22 different CT scanners from 4 manufacturers at 12 imaging centers. LSN scores were obtained using a software-based method. Repeatability and reproducibility were evaluated by intraclass correlation (ICC) and coefficient of variation. Using abdominal CT images from 68 patients with various stages of chronic liver disease, inter-observer agreement and test-retest repeatability among 12 readers assessing LSN by software- vs. visual-based scoring methods were evaluated by ICC. There was excellent repeatability of LSN scores (ICC:0.79-0.99) using the CT phantom and routine image acquisition and reconstruction parameters (kVp 100-140, mA 200-400, and auto-mA, section thickness 1.25-5.0 mm, field of view 35-50 cm, and smooth or standard kernels). There was excellent reproducibility (smooth ICC: 0.97; 95% CI 0.95, 0.99; CV: 7%; nodular ICC: 0.94; 95% CI 0.89, 0.97; CV: 8%) for LSN scores derived from CT images from 22 different scanners. Inter-observer agreement for the software-based LSN scoring method was excellent (ICC: 0.84; 95% CI 0.79, 0.88; CV: 28%) vs. good for the visual-based method (ICC: 0.61; 95% CI 0.51, 0.69; CV: 43%). Test-retest repeatability for the software-based LSN scoring method was excellent (ICC: 0.82; 95% CI 0.79, 0.84; CV: 12%). The software-based LSN score is a quantitative CT imaging biomarker with excellent repeatability, reproducibility, inter-observer agreement, and test-retest repeatability.
Zhou, Hua; Wang, Hongxia; Niu, Haitao; Gestos, Adrian; Wang, Xungai; Lin, Tong
2012-05-08
A superhydrophobic fabric coating made of a crosslinked polydimethylsiloxane elastomer, containing well-dispersed hydrophobic silica nanoparticles and fluorinated alkyl silane, shows remarkable durability against repeated machine washes, severe abrasion, strong acid or base, boiling water or beverages and excellent stain resistance. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A Dual-Range Strain Gage Weighing Transducer Employing Automatic Switching
Rodger A. Arola
1968-01-01
Describes a dual-range strain gage transducer which has proven to be an excellent weight-sensing device for weighing trees and tree-length logs; discusses basic principals of the design and operation; and shows that a single transducer having two sensitivity ranges with automatic internal switching can sense weight with good repeatability and that one calibration curve...
2018-01-01
This study aimed to assess and validate the repeatability and agreement of quantitative elastography of novel shear wave methods on four individual tissue-mimicking liver fibrosis phantoms with different known Young’s modulus. We used GE Logiq E9 2D-SWE, Philips iU22 ARFI (pSWE), Samsung TS80A SWE (pSWE), Hitachi Ascendus (SWM) and Transient Elastography (TE). Two individual investigators performed all measurements non-continued and in parallel. The methods were evaluated for inter- and intraobserver variability by intraclass correlation, coefficient of variation and limits of agreement using the median elastography value. All systems used in this study provided high repeatability in quantitative measurements in a liver fibrosis phantom and excellent inter- and intraclass correlations. All four elastography platforms showed excellent intra-and interobserver agreement (interclass correlation 0.981–1.000 and intraclass correlation 0.987–1.000) and no significant difference in mean elasticity measurements for all systems, except for TE on phantom 4. All four liver fibrosis phantoms could be differentiated by quantitative elastography, by all platforms (p<0.001). In the Bland-Altman analysis the differences in measurements were larger for the phantoms with higher Young’s modulus. All platforms had a coefficient of variation in the range 0.00–0.21 for all four phantoms, equivalent to low variance and high repeatability. PMID:29293527
Does Dry Eye Affect Repeatability of Corneal Topography Measurements?
Doğan, Aysun Şanal; Gürdal, Canan; Köylü, Mehmet Talay
2018-04-01
The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy). Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198) and gender (M/F: 4/29 vs. 8/32, p=0.366). Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90). The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.
NASA Technical Reports Server (NTRS)
Nguyen, Truong X.; Ely, Jay J.; Koppen, Sandra V.
2001-01-01
This paper describes the implementation of mode-stirred method for susceptibility testing according to the current DO-160D standard. Test results on an Engine Data Processor using the implemented procedure and the comparisons with the standard anechoic test results are presented. The comparison experimentally shows that the susceptibility thresholds found in mode-stirred method are consistently higher than anechoic. This is consistent with the recent statistical analysis finding by NIST that the current calibration procedure overstates field strength by a fixed amount. Once the test results are adjusted for this value, the comparisons with the anechoic results are excellent. The results also show that test method has excellent chamber to chamber repeatability. Several areas for improvements to the current procedure are also identified and implemented.
History, rare, and multiple events of mechanical unfolding of repeat proteins
NASA Astrophysics Data System (ADS)
Sumbul, Fidan; Marchesi, Arin; Rico, Felix
2018-03-01
Mechanical unfolding of proteins consisting of repeat domains is an excellent tool to obtain large statistics. Force spectroscopy experiments using atomic force microscopy on proteins presenting multiple domains have revealed that unfolding forces depend on the number of folded domains (history) and have reported intermediate states and rare events. However, the common use of unspecific attachment approaches to pull the protein of interest holds important limitations to study unfolding history and may lead to discarding rare and multiple probing events due to the presence of unspecific adhesion and uncertainty on the pulling site. Site-specific methods that have recently emerged minimize this uncertainty and would be excellent tools to probe unfolding history and rare events. However, detailed characterization of these approaches is required to identify their advantages and limitations. Here, we characterize a site-specific binding approach based on the ultrastable complex dockerin/cohesin III revealing its advantages and limitations to assess the unfolding history and to investigate rare and multiple events during the unfolding of repeated domains. We show that this approach is more robust, reproducible, and provides larger statistics than conventional unspecific methods. We show that the method is optimal to reveal the history of unfolding from the very first domain and to detect rare events, while being more limited to assess intermediate states. Finally, we quantify the forces required to unfold two molecules pulled in parallel, difficult when using unspecific approaches. The proposed method represents a step forward toward more reproducible measurements to probe protein unfolding history and opens the door to systematic probing of rare and multiple molecule unfolding mechanisms.
J.W." Jerry" Van Sambeek; Larry D. Godsey; William D. Walter; Harold E. Garrett; John P. Dwyer
2016-01-01
Benefits of repeated air-root-pruning of seedlings when stepping up to progressively larger containers include excellent lateral root distribution immediately below the root collar and an exceptionally fibrous root ball. To evaluate long-term field performance of repeatedly air-root-pruned container stock, three plantings of swamp white oak (Quercus bicolor...
A new approach to the measurement of pelvic asymmetry: proposed methods and reliability.
Gnat, Rafael; Biały, Maciej
2015-05-01
This is a methodological study presenting a novel method of pelvic asymmetry (PA) measurement for use in the research laboratory setting. The purpose of the study is (1) to establish intrarater and interrater reliability of the proposed measures of PA, (2) to verify the influence of repeated measurements on the reliability, and (3) to assess correlation between the proposed measures of PA. Twelve healthy volunteers participated, and 2 teams of raters were involved. Registration of anatomic landmarks' positions in the optical motion capture system was repeated 3 times. Two asymmetry indexes were calculated: for pelvic torsion and for lateral pelvic tilt. Interclass correlation coefficients (ICCs), standard errors of measurement, and smallest detectable differences were used to describe the intrarater and interrater reliability of the 2 indexes. After 2 repeated registrations of pelvic landmarks' positions, the reliability of our asymmetry indexes was good and excellent. The ICCs for intrarater reliability ranged from 0.96 to 0.97; the ICCs for interrater reliability ranged 0.81 to 0.90. There was moderate, nonsignificant correlation between asymmetry indexes for pelvis torsion and for lateral pelvic tilt (r = 0.45, P = .14). The 2 proposed asymmetry indexes showed good and excellent intrarater and interrater reliability after 2 repeated registrations of pelvic landmarks' positions and thus may be useful in the research laboratory setting. However, these indexes are not strongly correlated, which suggests that the 2 types of PA may constitute different clinical entities. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
Yu, Sha-Sha; Song, Hui; Tang, Xin
2017-01-01
AIM To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. METHODS Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability. RESULTS Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. CONCLUSION Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically. PMID:29181314
Yu, Sha-Sha; Song, Hui; Tang, Xin
2017-01-01
To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability. Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically.
Östling, Gerd; Nilsson, Peter M.
2015-01-01
Introduction Arterial stiffness is an independent risk factor for cardiovascular morbidity and can be assessed by applanation tonometry by measuring pulse wave velocity (PWV) and augmentation index (AIX) by pressure pulse wave analysis (PWA). As an inexpensive and operator independent alternative, photoelectric plethysmography (PPG) has been introduced with analysis of the digital volume pulse wave (DPA) and its second derivatives of wave reflections. Objective The objective was to investigate the repeatability of arterial stiffness parameters measured by digital pulse wave analysis (DPA) and the associations to applanation tonometry parameters. Methods and Results 112 pregnant and non-pregnant individuals of different ages and genders were examined with SphygmoCor arterial wall tonometry and Meridian DPA finger photoplethysmography. Coefficients of repeatability, Bland-Altman plots, intraclass correlation coefficients and correlations to heart rate (HR) and body height were calculated for DPA variables, and the DPA variables were compared to tonometry variables left ventricular ejection time (LVET), PWV and AIX. No DPA variable showed any systematic measurement error or excellent repeatability, but dicrotic index (DI), dicrotic dilatation index (DDI), cardiac ejection elasticity index (EEI), aging index (AI) and second derivatives of the crude pulse wave curve, b/a and e/a, showed good repeatability. Overall, the correlations to AIX were better than to PWV, with correlations coefficients >0.70 for EEI, AI and b/a. Considering the level of repeatability and the correlations to tonometry, the overall best DPA parameters were EEI, AI and b/a. The two pansystolic time parameters, ejection time compensated (ETc) by DPA and LVET by tonometry, showed a significant but weak correlation. Conclusion For estimation of the LV function, ETc, EEI and b/a are suitable, for large artery stiffness EEI, and for small arteries DI and DDI. The only global parameter, AI, showed a high repeatability and the overall best correlations with AIX and PWV. PMID:26291079
Marsella, Luca; Sirocco, Francesco; Trovato, Antonio; Seno, Flavio; Tosatto, Silvio C.E.
2009-01-01
Motivation: Proteins with solenoid repeats evolve more quickly than non-repetitive ones and their periodicity may be rapidly hidden at sequence level, while still evident in structure. In order to identify these repeats, we propose here a novel method based on a metric characterizing amino-acid properties (polarity, secondary structure, molecular volume, codon diversity, electric charge) using five previously derived numerical functions. Results: The five spectra of the candidate sequences coding for structural repeats, obtained by Discrete Fourier Transform (DFT), show common features allowing determination of repeat periodicity with excellent results. Moreover it is possible to introduce a phase space parameterized by two quantities related to the Fourier spectra which allow for a clear distinction between a non-homologous set of globular proteins and proteins with solenoid repeats. The DFT method is shown to be competitive with other state of the art methods in the detection of solenoid structures, while improving its performance especially in the identification of periodicities, since it is able to recognize the actual repeat length in most cases. Moreover it highlights the relevance of local structural propensities in determining solenoid repeats. Availability: A web tool implementing the algorithm presented in the article (REPETITA) is available with additional details on the data sets at the URL: http://protein.bio.unipd.it/repetita/. Contact: silvio.tosatto@unipd.it PMID:19478001
Huang, Jinhai; Savini, Giacomo; Wu, Fan; Yu, Xinxin; Yang, Jing; Yu, Ayong; Yu, Ye; Wang, Qinmei
2015-10-01
To assess the precision of ocular biometry with a new noncontact optical low-coherence interferometer (Aladdin) in healthy subjects and patients with cataracts. Eye Hospital of Wenzhou Medical University, Wenzhou, China. Observational cross-sectional study. Eyes from healthy subjects and eyes from patients with cataracts were examined with the new interferometer. Axial length (AL), anterior chamber depth (ACD), keratometry (K), and white-to-white (WTW) values were measured by 2 operators. The test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were calculated to evaluate intraoperator repeatability. Different-operator comparison was analyzed with paired t tests and Bland-Altman plots to assess interoperator reproducibility. Ninety-eight people were enrolled for this study, of which 52 eyes were from healthy subjects and 46 eyes were from patients with cataracts. The AL was the most repeatable and reproducible parameter. The ACD, K values, and WTW measurements were highly repeatable in healthy subjects with CoV less than 0.89% and ICC more than 0.94. However, in patients with cataracts, high repeatability could only be observed for AL, ACD, and K values, whereas WTW measurement had test-retest repeatability of 0.80 mm and an ICC of 0.795. Bland-Altman analysis also showed good agreement between the 2 operators for ocular component measurements, except that the WTW in patients with cataracts had wider 95% limits of agreement (range -0.88 to 0.95 mm). The new biometer showed excellent intraoperator repeatability and interoperator reproducibility for AL, ACD, and K values measurements in both groups. The precision of WTW measurements was lower in patients with cataracts. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Strampe, Margaret R; Huckenpahler, Alison L; Higgins, Brian P; Tarima, Sergey; Visotcky, Alexis; Stepien, Kimberly E; Kay, Christine N; Carroll, Joseph
2018-05-01
To examine repeatability and reproducibility of ellipsoid zone (EZ) width measurements in patients with retinitis pigmentosa (RP) using a longitudinal reflectivity profile (LRP) analysis. We examined Bioptigen optical coherence tomography (OCT) scans from 48 subjects with RP or Usher syndrome. Nominal scan lengths were 6, 7, or 10 mm, and the lateral scale of each scan was calculated using axial length measurements. LRPs were generated from OCT line scans, and the peak corresponding to EZ was manually identified using ImageJ. The locations at which the EZ peak disappeared were used to calculate EZ width. Each scan was analyzed twice by each of two observers, who were masked to their previous measurements and those of the other observer. On average, horizontal width (HW) was significantly greater than vertical width (VW), and there was high interocular symmetry for both HW and VW. We observed excellent intraobserver repeatability with intraclass correlation coefficients (ICCs) ranging from 0.996 to 0.998 for HW and VW measurements. Interobserver reproducibility was also excellent for both HW (ICC = 0.989; 95% confidence interval [CI] = 0.983-0.995) and VW (ICC = 0.991; 95% CI = 0.985-0.996), with no significant bias observed between observers. EZ width can be measured using LRPs with excellent repeatability and reproducibility. Our observation of greater HW than VW is consistent with previous observations in RP, though the reason for this anisotropy remains unclear. We describe repeatability and reproducibility of a method for measuring EZ width in patients with RP or Usher syndrome. This approach could facilitate measurement of retinal band thickness and/or intensity.
Diversity and Excellence in Higher Education: Is There a Conflict?
ERIC Educational Resources Information Center
Ghosh, Ratna
2012-01-01
In her teaching, research, and community activities in Canada, the author has repeatedly confronted questions regarding equality, diversity, and power. In this article, the author discusses diversity and equal opportunity to achieve excellence in education. Reflecting on these issues should help everyone to understand the complexities involved in…
Huang, Jinhai; Liao, Na; Savini, Giacomo; Li, Yuanguang; Bao, Fangjun; Yu, Ye; Yu, Ayong; Wang, Qinmei
2015-02-01
To determine the repeatability and reproducibility of measurements of central corneal thickness (CCT) using optical low-coherence reflectometry (Lenstar LS900; Haag Streit) in normal eyes and post-femtosecond laser in situ keratomileusis (post-FS-LASIK) eyes and evaluate their agreement with ultrasound (US) pachymetry. CCT was measured using Lenstar and US pachymetry sequentially in normal and post-FS-LASIK eyes by 2 experienced observers. Intraoperator repeatability and interoperator reproducibility were assessed by within-subject standard deviation, test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient. Paired t-tests and Bland-Altman plots were used for analyzing agreement between the 2 devices. In this study, 55 healthy subjects and 50 post-FS-LASIK patients were recruited. Test-retest repeatability of Lenstar was within 10 μm, CoV was less than 1.0%, and intraclass correlation coefficient was more than 0.9 in both normal and post-FS-LASIK groups. Mean difference between these methods was 1.4 ± 4.2 μm and -1.7 ± 5.4 μm, respectively. Moreover, measurements of CCT showed narrow 95% limits of agreement (range, normal group: -6.8 and 9.6 μm; post-FS-LASIK group: -12.4 and 8.9 μm), which implied good agreement. Measurements of CCT using Lenstar showed excellent intraoperator repeatability and interoperator reproducibility both in normal eyes and post-FS-LASIK eyes. Measurements of CCT using Lenstar and US pachymetry showed good agreement and both can be used interchangeably.
Niu, Zhiqiang; Zhou, Weiya; Chen, Jun; Feng, Guoxing; Li, Hong; Hu, Yongsheng; Ma, Wenjun; Dong, Haibo; Li, Jinzhu; Xie, Sishen
2013-02-25
Ultrathin SWCNT transparent and conductive films on flexible and transparent substrates are prepared via repeatedly halving the directly grown SWCNT films and flexible and transparent supercapacitors with excellent performance were fabricated. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, Y.Z., E-mail: singyuanzhi@sina.com; Zhou, J.F.; Song, Y., E-mail: songyang@mail.buct.edu.cn
Graphical abstract: Electrochemical deposition of netlike gold nanoparticles (GNPs) on the surface of glassy carbon electrode and preparation of netlike GNPs in aqueous solution using ampicillin as a stabilizing reagent were proposed. The catalytic properties of netlike gold nanoparticles on the glassy carbon electrode for dopamine were demonstrated. The results indicate that the netlike gold nanoparticle modified electrode has an excellent repeatability and reproducibility. Display Omitted Highlights: ► Synthesis of netlike gold nanoparticles using ampicillin as a stabilizing reagent. ► Excellent repeatability and reproducibility of netlike gold nanoparticle modified glassy carbon electrode. ► The catalytic properties of netlike gold nanoparticlemore » for dopamine. -- Abstract: Electrochemical deposition of netlike gold nanoparticles on the surface of glassy carbon electrode and preparation of netlike GNPs in aqueous solution using ampicillin as a stabilizing reagent were proposed. The netlike gold nanoparticles were characterized by scanning electron microscope, transmission electron microscope, infrared spectrometer, UV spectrophotometer, powder X-ray diffractometer and electrochemical analyzer. The catalysis of the netlike gold nanoparticles on the glassy carbon electrode for dopamine was demonstrated. The results indicate that the gold nanoparticle modified electrode has an excellent repeatability and reproducibility.« less
Strömberg, Tomas; Sjöberg, Folke; Bergstrand, Sara
2017-09-01
Forearm skin hyperemia during release after brachial occlusion has been proposed for evaluating peripheral arterial disease and endothelial dysfunction. We used a novel fiberoptic system integrating Laser Doppler Flowmetry and Diffuse Reflectance Spectroscopy for a comprehensive pointwise model based microcirculation characterization. The aim was to evaluate and compare the temporal and the spatiotemporal variabilities in forearm skin microcirculation parameters (speed resolved perfusion; low speed <1mm/s, Perf SR, <1 ; mid-speed 1-10mm/s, high speed >10mm/s, and total perfusion (Perf SR, tot ); the concentration and oxygenation of red blood cells, C RBC and S O2 ). Ten healthy subjects underwent arterial and venous forearm occlusions (AO, VO), repeated within one week. The repeatability was calculated as the coefficient of variation (CV) and the agreement as the intra-class correlation coefficient (ICC). The temporal CVs for conventional perfusion, Perf conv , Perf SR, tot , C RBC and S O2 were 14%, 12%, 9% and 9%, respectively, while the ICC were >0.75 (excellent). The perfusion measures generally had a higher spatiotemporal than temporal variability, which was not the case for S O2 and C RBC . The corresponding spatiotemporal CVs were 33%, 32%, 18% and 15%, respectively. During VO, C RBC had a CV<35% and ICC>0.40 (fair-good), and after release this was the case for C RBC (AO and VO), S O2 (VO) and Perf SR, <1 (VO). In conclusion, the skin microcirculation parameters showed excellent temporal repeatability, while the spatiotemporal repeatability especially for perfusion was poorer. The parameters with acceptable repeatability and fair-good agreement were: C RBC during and after release of VO, the Perf SR, <1 after release of VO, the S O2 and the C RBC after release of AO. However, the value of these parameters in discriminating endothelial function remains to be studied. Copyright © 2017 Elsevier Inc. All rights reserved.
The Stag Hunt Game: An Example of an Excel-Based Probabilistic Game
ERIC Educational Resources Information Center
Bridge, Dave
2016-01-01
With so many role-playing simulations already in the political science education literature, the recent repeated calls for new games is both timely and appropriate. This article answers and extends those calls by advocating the creation of probabilistic games using Microsoft Excel. I introduce the example of the Stag Hunt Game--a short, effective,…
NASA Astrophysics Data System (ADS)
Chen, Chieh-Li; Bojikian, Karine D.; Xin, Chen; Wen, Joanne C.; Gupta, Divakar; Zhang, Qinqin; Mudumbai, Raghu C.; Johnstone, Murray A.; Chen, Philip P.; Wang, Ruikang K.
2016-06-01
Optical coherence tomography angiography (OCTA) has increasingly become a clinically useful technique in ophthalmic imaging. We evaluate the repeatability and reproducibility of blood perfusion in the optic nerve head (ONH) measured using optical microangiography (OMAG)-based OCTA. Ten eyes from 10 healthy volunteers are recruited and scanned three times with a 68-kHz Cirrus HD-OCT 5000-based OMAG prototype system (Carl Zeiss Meditec Inc., Dublin, California) centered at the ONH involving two separate visits within six weeks. Vascular images are generated with OMAG processing by detecting the differences in OCT signals between consecutive B-scans acquired at the same retina location. ONH perfusion is quantified as flux, vessel area density, and normalized flux within the ONH for the prelaminar, lamina cribrosa, and the full ONH. Coefficient of variation (CV) and intraclass correlation coefficient (ICC) are used to evaluate intravisit and intervisit repeatability, and interobserver reproducibility. ONH perfusion measurements show high repeatability [CV≤3.7% (intravisit) and ≤5.2% (intervisit)] and interobserver reproducibility (ICC≤0.966) in all three layers by three metrics. OCTA provides a noninvasive method to visualize and quantify ONH perfusion in human eyes with excellent repeatability and reproducibility, which may add additional insight into ONH perfusion in clinical practice.
Cooper, Dale J; Scammell, Brigitte E; Batt, Mark E; Palmer, Debbie
2018-01-17
The impracticalities and comparative expense of carrying out a clinical assessment is an obstacle in many large epidemiological studies. The purpose of this study was to develop and validate a series of electronic self-reported line drawing instruments based on the modified Beighton scoring system for the assessment of self-reported generalised joint hypermobility. Five sets of line drawings were created to depict the 9-point Beighton score criteria. Each instrument consisted of an explanatory question whereby participants were asked to select the line drawing which best represented their joints. Fifty participants completed the self-report online instrument on two occasions, before attending a clinical assessment. A blinded expert clinical observer then assessed participants' on two occasions, using a standardised goniometry measurement protocol. Validity of the instrument was assessed by participant-observer agreement and reliability by participant repeatability and observer repeatability using unweighted Cohen's kappa (k). Validity and reliability were assessed for each item in the self-reported instrument separately, and for the sum of the total scores. An aggregate score for generalised joint hypermobility was determined based on a Beighton score of 4 or more out of 9. Observer-repeatability between the two clinical assessments demonstrated perfect agreement (k 1.00; 95% CI 1.00, 1.00). Self-reported participant-repeatability was lower but it was still excellent (k 0.91; 95% CI 0.74, 1.00). The participant-observer agreement was excellent (k 0.96; 95% CI 0.87, 1.00). Validity was excellent for the self-report instrument, with a good sensitivity of 0.87 (95% CI 0.81, 0.91) and excellent specificity of 0.99 (95% CI 0.98, 1.00). The self-reported instrument provides a valid and reliable assessment of the presence of generalised joint hypermobility and may have practical use in epidemiological studies.
Puri, Basant K; Egan, Mary; Wallis, Fintan; Jakeman, Philip
2018-03-22
To investigate the repeatability of proton magnetic resonance spectroscopy in the in vivo measurement of human cerebral levels of choline-containing compounds (Cho). Two consecutive scans were carried out in six healthy resting subjects at a magnetic field strength of 1.5 T. On each occasion, neurospectroscopy data were collected from 64 voxels using the same 2D chemical shift imaging (CSI) sequence. The data were analyzed in the same way, using the same software, to obtain the values for each voxel of the ratio of Cho to creatine. The Wilcoxon related-samples signed-rank test, coefficient of variation (CV), repeatability coefficient (RC), and intraclass correlation coefficient (ICC) were used to assess the repeatability. The CV ranged from 2.75% to 33.99%, while the minimum RC was 5.68%. There was excellent reproducibility, as judged by significant ICC values, in 26 voxels. Just three voxels showed significant differences according to the Wilcoxon related-samples signed-rank test. It is therefore concluded that when CSI multivoxel proton neurospectroscopy is used to measure cerebral choline-containing compounds at 1.5 T, the reproducibility is highly acceptable.
Dresler, Maria Magdalena; Kociszewski, Jacek; Pędraszewski, Piotr; Trzeciak, Agnieszka; Surkont, Grzegorz
2017-01-01
Introduction Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes. PMID:28856017
Evolution-Inspired Computational Design of Symmetric Proteins.
Voet, Arnout R D; Simoncini, David; Tame, Jeremy R H; Zhang, Kam Y J
2017-01-01
Monomeric proteins with a number of identical repeats creating symmetrical structures are potentially very valuable building blocks with a variety of bionanotechnological applications. As such proteins do not occur naturally, the emerging field of computational protein design serves as an excellent tool to create them from nonsymmetrical templates. Existing pseudo-symmetrical proteins are believed to have evolved from oligomeric precursors by duplication and fusion of identical repeats. Here we describe a computational workflow to reverse-engineer this evolutionary process in order to create stable proteins consisting of identical sequence repeats.
Furukawa, Koji; Hashimoto, Makoto; Kaneco, Satoshi
2017-01-01
A rapid determination of aniline in environmental water was examined based on liquid chromatography/tandem mass spectrometry (LC/MS/MS). Environmental water samples were diluted 20-fold with Mill-Q water and measured by LC/MS/MS after adding a surrogate substance (aniline-d 5 ). In the results of the present study, the calibration curve of aniline showed good linearity in the range of 0.05 - 2.0 μg/L. Since the RSD (repeatability) by measuring repeatedly an aniline standard solution (0.05 μg/L, n = 7) was 3.2%, the repeatability of this work was very excellent. In addition, the recovery rate of aniline in environmental water was in the range of 99.0 - 102% with RSD 3.4 - 7.7%, and very good recovery test results were obtained. From these results, this analytical method was confirmed to be effective for aniline measurements of environmental water samples. Also, it is possible to conduct rapid analyses of aniline in environmental water without any solid-phase extraction process, compared to the solid-phase extraction-GC/MS method.
Mostafa, Ayman A; Cunningham, Devin P; Boudrieau, Randy J; Kowaleski, Michael P; Griffon, Dominique J
2018-04-01
To determine repeatability of and correlation between 2 radiographic measurements of femoral anteversion angles (FAA) and to determine their influence on a score derived from tibial plateau angle (TPA) and FAA to predict the risk of cranial cruciate ligament disease (CCLD). Prospective clinical study. Forty-eight Labrador retrievers with or without CCLD. FAA and CCLD scores were calculated for each limb from extended pelvic radiographs (t-FAA) or angled (a-FAA) projections of the femur by 3 investigators. One investigator repeated measurements twice. Data were analyzed for repeatability, correlation between t-FAA and a-FAA, and their influence on CCLD scores. FAA correlated most strongly with the distance between the femoral head and the femoral axis on mediolateral radiographs, a measurement with excellent repeatability. t-FAA and a-FAA correlated with each other (r > 0.79, P < .0001), although t-FAA were about 1° greater than a-FAA (P = .01). Intrainvestigator and interinvestigator repeatability of the CCLD score was fair when derived from t-FAA and good to excellent when derived from a-FAA. CCLD scores differed between radiographic techniques but led to different predictions in only 9 (10%) limbs, all with lower TPA and CCLD scores than the rest of the population. a-FAA correlated strongly with t-FAA and improved the repeatability of CCLD scores within and between investigators. A craniocaudal angled beam projection of the femur is a suitable alternative to a ventrodorsal pelvic radiograph when measuring FAA and may improve the repeatability and positive predictive value of CCLD scores. © 2018 The American College of Veterinary Surgeons.
Ponrartana, Skorn; Andrade, Kristine E; Wren, Tishya A L; Ramos-Platt, Leigh; Hu, Houchun H; Bluml, Stefan; Gilsanz, Vicente
2014-06-01
The purpose of this study was to assess the repeatability of water-fat MRI and diffusion-tensor imaging (DTI) as quantitative biomarkers of pediatric lower extremity skeletal muscle. MRI at 3 T of a randomly selected thigh and lower leg of seven healthy children was studied using water-fat separation and DTI techniques. Muscle-fat fraction, apparent diffusion coefficient (ADC), and fractional anisotropy (FA) values were calculated. Test-retest and interrater repeatability were assessed by calculating the Pearson correlation coefficient, intraclass correlation coefficient, and Bland-Altman analysis. Bland-Altman plots show that the mean difference between test-retest and interrater measurements of muscle-fat fraction, ADC, and FA was near 0. The correlation coefficients and intraclass correlation coefficients were all between 0.88 and 0.99 (p < 0.05), suggesting excellent reliability of the measurements. Muscle-fat fraction measurements from water-fat MRI exhibited the highest intraclass correlation coefficient. Interrater agreement was consistently better than test-retest comparisons. Water-fat MRI and DTI measurements in lower extremity skeletal muscles are objective repeatable biomarkers in children. This knowledge should aid in the understanding of the number of participants needed in clinical trials when using these determinations as an outcome measure to noninvasively monitor neuromuscular disease.
Ghosh, Saurabh; Bonshek, Richard; Morgan, Stephen J
2013-01-01
Purpose To report a case of corneal graft failure due to epithelial ingrowth after an uneventful combined Descemet stripping automated endothelial keratoplasty (DSAEK) and phacoemulsification cataract surgery with intraocular lens implant treated successfully with a repeat DSAEK. Methods A 77-year-old male patient underwent combined DSAEK and phacoemulsification with intraocular lens implant implantation for Fuchs’ endothelial dystrophy plus cataract in the right eye. The donor cornea was cut on the Moria ALTK system and introduced using a suture pull-through technique. After an episode of endothelial rejection, the graft failed, with signs suggesting epithelial ingrowth. It was stripped from the host cornea using a Descemet’s membrane stripper, and a Simcoe irrigation-aspiration cannula was used to remove all traces of interface material. The excised lenticule was examined histologically using a hematoxylin and eosin stain. Result The patient regained and maintained excellent visual acuity with no sign of recurrence of epithelial ingrowth. Histopathological evaluation of the donor tissue of the first graft showed epithelial ingrowth on the stromal surface of the graft and very few endothelial cells, in keeping with the diagnosis of graft failure. Conclusion Epithelial ingrowth is a possible cause of endothelial graft failure, but histologically proven cases are rare. Surgical intervention can achieve successful clearance, with the potential for cure and an excellent outcome. PMID:23754868
A parent‐completed respiratory questionnaire for 1‐year‐old children: repeatability
Strippoli, Marie‐Pierre F; Silverman, Michael; Michel, Gisela; Kuehni, Claudia E
2007-01-01
Background and aims There are few standardised questionnaires for the assessment of respiratory symptoms in preschool children. We have developed and tested the short‐term repeatability of a postal questionnaire on respiratory symptoms for 1‐year‐old children. Methods A newly developed postal questionnaire for the assessment of wheeze and other respiratory symptoms was sent to parents of a population‐based random sample of 4300 children aged 12–24 months. After an interval of 3 months, a random sample of 800 respondents received the questionnaire a second time. The responses were compared using Cohen's kappa (κ) to assess agreement corrected for chance. Results The first questionnaire was returned by 3194 (74%) families, the second one by 460/800 (58%). Repeatability was excellent (κ 0.80–0.96) for questions on household characteristics, environmental exposures and family history, good (κ 0.61–0.80) for questions on prevalence, severity and treatment of wheeze, and moderate (κ 0.39–0.66) for chronic cough and upper respiratory symptoms. Conclusions This short postal questionnaire designed for use in population‐based studies has excellent repeatability for family and household characteristics and good repeatability for questions on wheeze. Short‐term changes in symptom status might be responsible for variable answers on recent chronic cough and upper respiratory symptoms. Overall, the questionnaire is a valuable instrument for community‐based research on respiratory symptoms in 1 to 2‐year‐old children. PMID:17502330
Precision and repeatability of the Optotrak 3020 motion measurement system.
States, R A; Pappas, E
2006-01-01
Several motion analysis systems are used by researchers to quantify human motion and to perform accurate surgical procedures. The Optotrak 3020 is one of these systems and despite its widespread use there is not any published information on its precision and repeatability. We used a repeated measures design study to evaluate the precision and repeatability of the Optotrak 3020 by measuring distance and angle in three sessions, four distances and three conditions (motion, static vertical, and static tilted). Precision and repeatability were found to be excellent for both angle and distance although they decreased with increasing distance from the sensors and with tilt from the plane of the sensors. Motion did not have a significant effect on the precision of the measurements. In conclusion, the measurement error of the Optotrak is minimal. Further studies are needed to evaluate its precision and repeatability under human motion conditions.
Validity of automated refraction after segmented refractive multifocal intraocular lens implantation
Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo
2017-01-01
AIM To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). METHODS Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. RESULTS Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected. PMID:29181318
Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo
2017-01-01
To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.
Reproducibility of the vertical dimension of occlusion with an improved measuring gauge.
Morikawa, M; Kozono, Y; Noguchi, B S; Toyoda, S
1988-07-01
An improved gauge using an eyeglass frame, the TOM gauge, was devised. The reproducibility of the record of vertical dimension with this gauge was evaluated through repeated measurements on subjects having a definite centric stop with the natural dentition. Because of the stabilization provided by the frame and the reference point on the apex nasi, the TOM gauge showed excellent reproducibility of the record compared with the conventional gauges. The TOM gauge can be expected to significantly reduce the risk of errors in measuring the vertical dimension of occlusion especially in complete denture fabrication.
Precise and rapid isotopomic analysis by (1)H-(13)C 2D NMR: Application to triacylglycerol matrices.
Merchak, Noelle; Silvestre, Virginie; Rouger, Laetitia; Giraudeau, Patrick; Rizk, Toufic; Bejjani, Joseph; Akoka, Serge
2016-08-15
An optimized HSQC sequence was tested and applied to triacylglycerol matrices to determine their isotopic and metabolomic profiles. Spectral aliasing and non-uniform sampling approaches were used to decrease the experimental time and to improve the resolution, respectively. An excellent long-term repeatability of signal integrals was achieved enabling to perform isotopic measurements. Thirty-two commercial vegetable oils were analyzed by this methodology. The results show that this method can be used to classify oil samples according to their geographical and botanical origins. Copyright © 2016 Elsevier B.V. All rights reserved.
Zhang, Lijing; Cao, Hua; Zhang, Jiaxin; Yang, Chengli; Hu, Tingting; Li, Huili; Yang, Wu; He, Gu; Song, Xiangrong; Tong, Aiping; Guo, Gang; Li, Rui; Jiang, Yu; Liu, Jiyan; Cai, Lulu; Zheng, Yu
2017-02-01
Specific delivery of drugs to bone tissue is very challenging due to the architecture and structure of bone tissue. A seven-repeat sequence of aspartate, a representative bone-targeting oligopeptide, is preferentially used for targeted therapy for bone diseases. In this study, Asp7-cholesterol((Asp)7-CHOL) was synthesized and (Asp)7-CHOL-modified liposome loaded with doxorubicin (DOX) was successfully prepared using both pre-insertion (pre-L) and post-insertion (post-L) methods. The formulation was optimized according to particle size, zeta potential and the drug-loading efficiency of the liposome. In addition, the bone affinity of the (Asp)7-CHOL-modified liposome was evaluated using a hydroxyapatite (HA) absorption method. The results suggested that (Asp)7-CHOL-modified liposome show excellent HA absorption; pre-L showed slightly higher HA binding than post-L. However, post-L had a higher DOX entrapment efficiency than pre-L. In vivo imaging further demonstrated that pre-L showed a higher bone-targeting efficiency than post-L, which was consistent with in vitro results. In all, (Asp)7-CHOL-modified liposome showed excellent bone-targeting activity, suggesting their potential for use as a drug delivery system for bone disease-targeted therapies.
Deployment Testing of Flexible Composite Hinges in Bi-Material Beams
NASA Technical Reports Server (NTRS)
Sauder, Jonathan F.; Trease, Brian
2016-01-01
Composites have excellent properties for strength, thermal stability, and weight. However, they are traditionally highly rigid, and when used in deployable structures require hinges bonded to the composite material, which increases complexity and opportunities for failure. Recent research in composites has found by adding an elastomeric soft matrix, often silicone instead of an epoxy, the composite becomes flexible. This work explores the deployment repeatability of silicone matrix composite hinges which join rigid composite beams. The hinges were found to have sub-millimeter linear deployment repeatability, and sub-degree angular deployment repeatability. Also, an interesting relaxation effect was discovered, as a hinges deployment error would decrease with time.
Glutamate quantification by PRESS or MEGA-PRESS: Validation, repeatability, and concordance.
van Veenendaal, Tamar M; Backes, Walter H; van Bussel, Frank C G; Edden, Richard A E; Puts, Nicolaas A J; Aldenkamp, Albert P; Jansen, Jacobus F A
2018-05-01
While PRESS is often employed to measure glutamate concentrations, MEGA-PRESS enables simultaneous Glx (glutamate and glutamine) and GABA measurements. This study aimed to compare validation, repeatability, and concordance of different approaches for glutamate quantification at 3T to aid future studies in their selection of the appropriate sequence and quantification method. Nine phantoms with different glutamate and glutamine concentrations and five healthy participants were scanned twice to assess respectively the validation and repeatability of measurements with PRESS and MEGA-PRESS. To assess concordance between the different methods, results from 95 human participants were compared. PRESS, MEGA-PRESS (i.e. difference), and the MEGA-PRESS OFF spectra were analyzed with both LCModel and Gannet. In vitro, excellent agreement was shown between actual and measured glutamate concentrations for all measurements (r>0.98). In vivo CVs were better for PRESS (2.9%) than MEGA-PRESS (4.9%) and MEGA-PRESS OFF (4.2%). However, the concordance between the sequences was low (PRESS and MEGA-PRESS OFF, r=0.3) to modest (MEGA-PRESS versus MEGA-PRESS OFF, r=0.8). Both PRESS and MEGA-PRESS can be employed to measure in vivo glutamate concentrations, although PRESS shows a better repeatability. Comparisons between in vivo glutamate measures of different sequences however need to be interpreted cautiously. Copyright © 2018 Elsevier Inc. All rights reserved.
Bioimpedance for the spot measurement of tissue density
NASA Astrophysics Data System (ADS)
Dylke, E. S.; Ward, L. C.; Stannard, C.; Leigh, A.; Kilbreath, S. L.
2013-04-01
Long-standing lymphoedema is characterised by tissues changes which are currently not detectable using bioimpedance spectroscopy. It has been suggested that a combination of bipolar and tetrapolar measurements may be used to detect these tissues changes for a single site in the transverse direction. This was technique was trialled in a group of control participants with no history of lymphoedema or recent upper limb trauma. Repeated spot measurements were done without removal of electrodes to determine biological variability as well as with removal of electrodes to determine technical reproducibility. The inter-limb spot ratio of the controls was then compared to that of a number of women previously diagnosed with secondary lymphoedema in the forearm. Biological variability was not found to greatly influence repeated measures but only moderate technical reliability was found despite excellent co-efficient of variation for the majority of the measurements. A difference was seen between those with more severe swelling and the controls. This novel technique shows promise in detecting tissue changes associated with long-standing lymphoedema.
Accuracy and Reliability of the Kinect Version 2 for Clinical Measurement of Motor Function
Kayser, Bastian; Mansow-Model, Sebastian; Verrel, Julius; Paul, Friedemann; Brandt, Alexander U.; Schmitz-Hübsch, Tanja
2016-01-01
Background The introduction of low cost optical 3D motion tracking sensors provides new options for effective quantification of motor dysfunction. Objective The present study aimed to evaluate the Kinect V2 sensor against a gold standard motion capture system with respect to accuracy of tracked landmark movements and accuracy and repeatability of derived clinical parameters. Methods Nineteen healthy subjects were concurrently recorded with a Kinect V2 sensor and an optical motion tracking system (Vicon). Six different movement tasks were recorded with 3D full-body kinematics from both systems. Tasks included walking in different conditions, balance and adaptive postural control. After temporal and spatial alignment, agreement of movements signals was described by Pearson’s correlation coefficient and signal to noise ratios per dimension. From these movement signals, 45 clinical parameters were calculated, including ranges of motions, torso sway, movement velocities and cadence. Accuracy of parameters was described as absolute agreement, consistency agreement and limits of agreement. Intra-session reliability of 3 to 5 measurement repetitions was described as repeatability coefficient and standard error of measurement for each system. Results Accuracy of Kinect V2 landmark movements was moderate to excellent and depended on movement dimension, landmark location and performed task. Signal to noise ratio provided information about Kinect V2 landmark stability and indicated larger noise behaviour in feet and ankles. Most of the derived clinical parameters showed good to excellent absolute agreement (30 parameters showed ICC(3,1) > 0.7) and consistency (38 parameters showed r > 0.7) between both systems. Conclusion Given that this system is low-cost, portable and does not require any sensors to be attached to the body, it could provide numerous advantages when compared to established marker- or wearable sensor based system. The Kinect V2 has the potential to be used as a reliable and valid clinical measurement tool. PMID:27861541
NASA Astrophysics Data System (ADS)
Park, Hyung Ju; Chi, Young Shik; Choi, Insung S.; Yun, Wan Soo
2010-07-01
We report a simple method of enhancing electric conductance in nanogap devices without any additional treatments, such as silver-enhancing process. The low electric conductance after selective immobilization of biofunctionalized gold nanoparticles in the gap region was greatly enhanced by repeated I-V scans at relatively high voltage ranges of -5 to 5 V, which was attributed to the formation of a new conduction pathway across the gap. The higher conduction state of the nanogap device showed a very stable I-V curve, which was used as an excellent measure of the existence of prostate-specific antigen.
Optical fiber pressure sensor based on fiber Bragg grating
NASA Astrophysics Data System (ADS)
Song, Dongcao
In oil field, it is important to measure the high pressure and temperature for down-hole oil exploration and well-logging, the available traditional electronic sensor is challenged due to the harsh, flammable environment. Recently, applications based on fiber Bragg grating (FBG) sensor in the oil industry have become a popular research because of its distinguishing advantages such as electrically passive operation, immunity to electromagnetic interference, high resolution, insensitivity to optical power fluctuation etc. This thesis is divided into two main sections. In the first section, the design of high pressure sensor based on FBG is described. Several sensing elements based on FBG for high pressure measurements have been proposed, for example bulk-modulus or free elastic modulus. But the structure of bulk-modulus and free elastic modulus is relatively complex and not easy to fabricate. In addition, the pressure sensitivity is not high and the repeatability of the structure has not been investigated. In this thesis, a novel host material of carbon fiber laminated composite (CFLC) for high pressure sensing is proposed. The mechanical characteristics including principal moduli in three directions and the shape repeatability are investigated. Because of it's Young's modulus in one direction and anisotropic characteristics, the pressure sensor made by CFLC has excellent sensitivity. This said structure can be used in very high pressure measurement due to carbon fiber composite's excellent shape repetition even under high pressure. The experimental results show high pressure sensitivity of 0.101nm/MPa and high pressure measurement up to 70MPa. A pressure sensor based on CFLC and FBG with temperature compensation has been designed. In the second section, the design of low pressure sensor based on FBG is demonstrated. Due to the trade off between measurement range and sensitivity, a sensor for lower pressure range needs more sensitivity. A novel material of carbon fiber ribbon-wound composite cylindrical shell is proposed. The mechanical characteristics are analyzed. Due to the smaller longitudinal Young's modulus of this novel material, the sensitivity is improved to 0.452nm/MPa and the measurement range can reach 8MPa. The experimental results indicated excellent repeatability of the material and a good linearity between Bragg wavelength shift and the applied pressure. The sensor has the potential to find many industrial low pressure applications.
Mass Manufacturing Challenges For CPV Primary And Secondary Optics
NASA Astrophysics Data System (ADS)
Luce, Thomas; Cohen, Joel
2010-10-01
Crucial for the performance and longevity of CPV installations is the efficiency of the optics used. Low production cost and high performance are key for the economical success of a CPV concept. To be able to compete with existing energy sources, proven mass production methods as well as high performance materials have to be employed. The injection molding process is the ideal serial production process capable to deliver at the same time high part quantities, excellent part precision and repeatable part quality at low manufacturing cost. Primary and secondary optics require different materials to be applied. The Pros and Cons of these materials in terms of production properties and achievable part precision will be discussed. We will show quality results for primary Fresnel optics using PMMA and, alternatively Silicone on Glass. For secondary optics we will demonstrate the use of optical silicone lenses widely used for high power LED applications today. Optical grade silicone has an excellent environmental stability even when encountering high energy density levels. The experience of Eschenbach Optik in injection molding silicone optics shows that this material is a very cost competitive alternative for glass secondary optics providing both highest optical performance and precision.
Nüesch, Corina; Roos, Elena; Pagenstert, Geert; Mündermann, Annegret
2017-05-24
Inertial sensor systems are becoming increasingly popular for gait analysis because their use is simple and time efficient. This study aimed to compare joint kinematics measured by the inertial sensor system RehaGait® with those of an optoelectronic system (Vicon®) for treadmill walking and running. Additionally, the test re-test repeatability of kinematic waveforms and discrete parameters for the RehaGait® was investigated. Twenty healthy runners participated in this study. Inertial sensors and reflective markers (PlugIn Gait) were attached according to respective guidelines. The two systems were started manually at the same time. Twenty consecutive strides for walking and running were recorded and each software calculated sagittal plane ankle, knee and hip kinematics. Measurements were repeated after 20min. Ensemble means were analyzed calculating coefficients of multiple correlation for waveforms and root mean square errors (RMSE) for waveforms and discrete parameters. After correcting the offset between waveforms, the two systems/models showed good agreement with coefficients of multiple correlation above 0.950 for walking and running. RMSE of the waveforms were below 5° for walking and below 8° for running. RMSE for ranges of motion were between 4° and 9° for walking and running. Repeatability analysis of waveforms showed very good to excellent coefficients of multiple correlation (>0.937) and RMSE of 3° for walking and 3-7° for running. These results indicate that in healthy subjects sagittal plane joint kinematics measured with the RehaGait® are comparable to those using a Vicon® system/model and that the measured kinematics have a good repeatability, especially for walking. Copyright © 2017 Elsevier Ltd. All rights reserved.
Pourcel, Christine; Minandri, Fabrizia; Hauck, Yolande; D'Arezzo, Silvia; Imperi, Francesco; Vergnaud, Gilles; Visca, Paolo
2011-01-01
Acinetobacter baumannii is an important opportunistic pathogen responsible for nosocomial outbreaks, mostly occurring in intensive care units. Due to the multiplicity of infection sources, reliable molecular fingerprinting techniques are needed to establish epidemiological correlations among A. baumannii isolates. Multiple-locus variable-number tandem-repeat analysis (MLVA) has proven to be a fast, reliable, and cost-effective typing method for several bacterial species. In this study, an MLVA assay compatible with simple PCR- and agarose gel-based electrophoresis steps as well as with high-throughput automated methods was developed for A. baumannii typing. Preliminarily, 10 potential polymorphic variable-number tandem repeats (VNTRs) were identified upon bioinformatic screening of six annotated genome sequences of A. baumannii. A collection of 7 reference strains plus 18 well-characterized isolates, including unique types and representatives of the three international A. baumannii lineages, was then evaluated in a two-center study aimed at validating the MLVA assay and comparing it with other genotyping assays, namely, macrorestriction analysis with pulsed-field gel electrophoresis (PFGE) and PCR-based sequence group (SG) profiling. The results showed that MLVA can discriminate between isolates with identical PFGE types and SG profiles. A panel of eight VNTR markers was selected, all showing the ability to be amplified and good amounts of polymorphism in the majority of strains. Independently generated MLVA profiles, composed of an ordered string of allele numbers corresponding to the number of repeats at each VNTR locus, were concordant between centers. Typeability, reproducibility, stability, discriminatory power, and epidemiological concordance were excellent. A database containing information and MLVA profiles for several A. baumannii strains is available from http://mlva.u-psud.fr/. PMID:21147956
Investigation of relationships between AIMS shape properties and VST friction values.
DOT National Transportation Integrated Search
2015-02-01
A thorough analysis was conducted for AIMS shape properties measured for virgin aggregates, aggregates : polished in the Micro-Deval (MD) for 105 and 210 minutes, and VST friction samples. Excellent repeatability of : AIMS angularity and texture meas...
Daneshfar, Amin; Gahreman, Daniel E.; Koozehchian, Majid S.; Amani Shalamzari, Sadegh; Hassanzadeh Sablouei, Mozhgan; Rosemann, Thomas; Knechtle, Beat; Nikolaidis, Pantelis T.
2018-01-01
The aim of the present study was to examine the validity and reliability of a 10 × (6 × 5 m) multi-directional repeated sprint ability test (RSM) in elite young team handball (TH) players. Participants were members of the Iranian national team (n = 20, age 16.4 ± 0.7 years, weight 82.5 ± 5.5 kg, height 184.8 ± 4.6 cm, body fat 15.4 ± 4.3%). The validity of RSM was tested against a 10 × (15 + 15 m) repeated sprint ability test (RSA), Yo-Yo Intermittent Recovery test Level 1 (Yo-Yo IR1), squat jump (SJ) and countermovement jump (CMJ). To test the reliability of RSM, the participants repeated the testing sessions of RSM and RSA 1 week later. Both RSA and RSM tests showed good to excellent reliability of the total time (TT), best time (BT), and weakest time (WT). The results of the correlation analysis showed significant inverse correlations between maximum aerobic capacity and TT in RSA (r = −0.57, p ≤ 0.05) and RSM (r = −0.76, p ≤ 0.01). There was also a significant inverse correlation between maximum aerobic capacity with fatigue index (FI) in RSA test (r = −0.64, p ≤ 0.01) and in RSM test (r = −0.53, p ≤ 0.05). BT, WT, and TT of RSA was largely-to-very largely correlated with BT (r = 0.58, p ≤ 0.01), WT (r = 0.62, p ≤ 0.01), and TT (r = 0.65, p ≤ 0.01) of RSM. BT in RSM was also correlated with FI in RSM (r = 0.88, p ≤ 0.01). In conclusion, based on the findings of the current study, the recently developed RSM test is a valid and reliable test and should be utilized for assessment of repeated sprint ability in handball players. PMID:29670536
Daneshfar, Amin; Gahreman, Daniel E; Koozehchian, Majid S; Amani Shalamzari, Sadegh; Hassanzadeh Sablouei, Mozhgan; Rosemann, Thomas; Knechtle, Beat; Nikolaidis, Pantelis T
2018-01-01
The aim of the present study was to examine the validity and reliability of a 10 × (6 × 5 m) multi-directional repeated sprint ability test (RSM) in elite young team handball (TH) players. Participants were members of the Iranian national team ( n = 20, age 16.4 ± 0.7 years, weight 82.5 ± 5.5 kg, height 184.8 ± 4.6 cm, body fat 15.4 ± 4.3%). The validity of RSM was tested against a 10 × (15 + 15 m) repeated sprint ability test (RSA), Yo-Yo Intermittent Recovery test Level 1 (Yo-Yo IR1), squat jump (SJ) and countermovement jump (CMJ). To test the reliability of RSM, the participants repeated the testing sessions of RSM and RSA 1 week later. Both RSA and RSM tests showed good to excellent reliability of the total time (TT), best time (BT), and weakest time (WT). The results of the correlation analysis showed significant inverse correlations between maximum aerobic capacity and TT in RSA ( r = -0.57, p ≤ 0.05) and RSM ( r = -0.76, p ≤ 0.01). There was also a significant inverse correlation between maximum aerobic capacity with fatigue index (FI) in RSA test ( r = -0.64, p ≤ 0.01) and in RSM test ( r = -0.53, p ≤ 0.05). BT, WT, and TT of RSA was largely-to-very largely correlated with BT ( r = 0.58, p ≤ 0.01), WT ( r = 0.62, p ≤ 0.01), and TT ( r = 0 .65, p ≤ 0.01) of RSM. BT in RSM was also correlated with FI in RSM ( r = 0.88, p ≤ 0.01). In conclusion, based on the findings of the current study, the recently developed RSM test is a valid and reliable test and should be utilized for assessment of repeated sprint ability in handball players.
Herold, Ingeborg H F; Saporito, Salvatore; Bouwman, R Arthur; Houthuizen, Patrick; van Assen, Hans C; Mischi, Massimo; Korsten, Hendrikus H M
2016-01-05
The aim of this study is to investigate the inter and intra-rater reliability, repeatability, and reproducibility of pulmonary transit time (PTT) measurement in patients using contrast enhanced ultrasound (CEUS), as an indirect measure of preload and left ventricular function. Mean transit times (MTT) were measured by drawing a region of interest (ROI) in right and left cardiac ventricle in the CEUS loops. Acoustic intensity dilution curves were obtained from the ROIs. MTTs were calculated by applying model-based fitting on the dilution curves. PTT was calculated as the difference of the MTTs. Eight raters with different levels of experience measured the PTT (time moment 1) and repeated the measurement within a week (time moment 2). Reliability and agreement were assessed using intra-class correlations (ICC) and Bland-Altman analysis. Repeatability was tested by estimating the variance of means (ANOVA) of three injections in each patient at different doses. Reproducibility was tested by the ICC of the two time moments. Fifteen patients with heart failure were included. The mean PTT was 11.8 ± 3.1 s at time moment 1 and 11.7 ± 2.9 s at time moment 2. The inter-rater reliability for PTT was excellent (ICC = 0.94). The intra-rater reliability per rater was between 0.81-0.99. Bland-Altman analysis revealed a bias of 0.10 s within the rater groups. Reproducibility for PTT showed an ICC = 0.94 between the two time moments. ANOVA showed no significant difference between the means of the three different doses F = 0.048 (P = 0.95). The mean and standard deviation for PTT estimates at three different doses was 11.6 ± 3.3 s. PTT estimation using CEUS shows a high inter- and intra-rater reliability, repeatability at three different doses, and reproducibility by ROI drawing. This makes the minimally invasive PTT measurement using contrast echocardiography ready for clinical evaluation in patients with heart failure and for preload estimation.
England, Clare Y; Thompson, Janice L; Jago, Russ; Cooper, Ashley R; Andrews, Rob C
2017-02-01
Dietary advice is fundamental in the prevention and management of type 2 diabetes (T2DM). Advice is improved by individual assessment but existing methods are time-consuming and require expertise. We developed a twenty-five-item questionnaire, the UK Diabetes and Diet Questionnaire (UKDDQ), for quick assessment of an individual's diet. The present study examined the UKDDQ's repeatability and relative validity compared with 4 d food diaries. The UKDDQ was completed twice with a median 3 d gap (interquartile range=1-7 d) between tests. A 4 d food diary was completed after the second UKDDQ. Diaries were analysed and food groups were mapped on to the UKDDQ. Absolute agreement between total scores was examined using intra-class correlation (ICC). Agreement for individual items was tested with Cohen's weighted kappa (κ w). South West of England. Adults (n 177, 50·3 % women) with, or at high risk for, T2DM; mean age 55·8 (sd 8·6) years, mean BMI 34·4 (sd 7·3) kg/m2; participants were 91 % White British. The UKDDQ showed excellent repeatability (ICC=0·90 (0·82, 0·94)). For individual items, κ w ranged from 0·43 ('savoury pastries') to 0·87 ('vegetables'). Total scores from the UKDDQ and food diaries compared well (ICC=0·54 (0·27, 0·70)). Agreement for individual items varied and was good for 'alcohol' (κ w=0·71) and 'breakfast cereals' (κ w=0·70), with no agreement for 'vegetables' (κ w=0·08) or 'savoury pastries' (κ w=0·09). The UKDDQ is a new British dietary questionnaire with excellent repeatability. Comparisons with food diaries found agreements similar to those for international dietary questionnaires currently in use. It targets foods and habits important in diabetes prevention and management.
Machado, Filipe Brum; Machado, Fabricio Brum; Faria, Milena Amendro; Lovatel, Viviane Lamim; Alves da Silva, Antonio Francisco; Radic, Claudia Pamela; De Brasi, Carlos Daniel; Rios, Álvaro Fabricio Lopes; de Sousa Lopes, Susana Marina Chuva; da Silveira, Leonardo Serafim; Ruiz-Miranda, Carlos Ramon; Ramos, Ester Silveira; Medina-Acosta, Enrique
2014-01-01
X-chromosome inactivation (XCI) is the epigenetic transcriptional silencing of an X-chromosome during the early stages of embryonic development in female eutherian mammals. XCI assures monoallelic expression in each cell and compensation for dosage-sensitive X-linked genes between females (XX) and males (XY). DNA methylation at the carbon-5 position of the cytosine pyrimidine ring in the context of a CpG dinucleotide sequence (5meCpG) in promoter regions is a key epigenetic marker for transcriptional gene silencing. Using computational analysis, we revealed an extragenic tandem GAAA repeat 230-bp from the landmark CpG island of the human X-linked retinitis pigmentosa 2 RP2 promoter whose 5meCpG status correlates with XCI. We used this RP2 onshore tandem GAAA repeat to develop an allele-specific 5meCpG-based PCR assay that is highly concordant with the human androgen receptor (AR) exonic tandem CAG repeat-based standard HUMARA assay in discriminating active (Xa) from inactive (Xi) X-chromosomes. The RP2 onshore tandem GAAA repeat contains neutral features that are lacking in the AR disease-linked tandem CAG repeat, is highly polymorphic (heterozygosity rates approximately 0.8) and shows minimal variation in the Xa/Xi ratio. The combined informativeness of RP2/AR is approximately 0.97, and this assay excels at determining the 5meCpG status of alleles at the Xp (RP2) and Xq (AR) chromosome arms in a single reaction. These findings are relevant and directly translatable to nonhuman primate models of XCI in which the AR CAG-repeat is monomorphic. We conducted the RP2 onshore tandem GAAA repeat assay in the naturally occurring chimeric New World monkey marmoset (Callitrichidae) and found it to be informative. The RP2 onshore tandem GAAA repeat will facilitate studies on the variable phenotypic expression of dominant and recessive X-linked diseases, epigenetic changes in twins, the physiology of aging hematopoiesis, the pathogenesis of age-related hematopoietic malignancies and the clonality of cancers in human and nonhuman primates.
Machado, Filipe Brum; Machado, Fabricio Brum; Faria, Milena Amendro; Lovatel, Viviane Lamim; Alves da Silva, Antonio Francisco; Radic, Claudia Pamela; De Brasi, Carlos Daniel; Rios, Álvaro Fabricio Lopes; de Sousa Lopes, Susana Marina Chuva; da Silveira, Leonardo Serafim; Ruiz-Miranda, Carlos Ramon; Ramos, Ester Silveira; Medina-Acosta, Enrique
2014-01-01
X-chromosome inactivation (XCI) is the epigenetic transcriptional silencing of an X-chromosome during the early stages of embryonic development in female eutherian mammals. XCI assures monoallelic expression in each cell and compensation for dosage-sensitive X-linked genes between females (XX) and males (XY). DNA methylation at the carbon-5 position of the cytosine pyrimidine ring in the context of a CpG dinucleotide sequence (5meCpG) in promoter regions is a key epigenetic marker for transcriptional gene silencing. Using computational analysis, we revealed an extragenic tandem GAAA repeat 230-bp from the landmark CpG island of the human X-linked retinitis pigmentosa 2 RP2 promoter whose 5meCpG status correlates with XCI. We used this RP2 onshore tandem GAAA repeat to develop an allele-specific 5meCpG-based PCR assay that is highly concordant with the human androgen receptor (AR) exonic tandem CAG repeat-based standard HUMARA assay in discriminating active (Xa) from inactive (Xi) X-chromosomes. The RP2 onshore tandem GAAA repeat contains neutral features that are lacking in the AR disease-linked tandem CAG repeat, is highly polymorphic (heterozygosity rates approximately 0.8) and shows minimal variation in the Xa/Xi ratio. The combined informativeness of RP2/AR is approximately 0.97, and this assay excels at determining the 5meCpG status of alleles at the Xp (RP2) and Xq (AR) chromosome arms in a single reaction. These findings are relevant and directly translatable to nonhuman primate models of XCI in which the AR CAG-repeat is monomorphic. We conducted the RP2 onshore tandem GAAA repeat assay in the naturally occurring chimeric New World monkey marmoset (Callitrichidae) and found it to be informative. The RP2 onshore tandem GAAA repeat will facilitate studies on the variable phenotypic expression of dominant and recessive X-linked diseases, epigenetic changes in twins, the physiology of aging hematopoiesis, the pathogenesis of age-related hematopoietic malignancies and the clonality of cancers in human and nonhuman primates. PMID:25078280
Van den Kerckhove, Eric; Fieuws, Steffen; Massagé, Patrick; Hierner, Robert; Boeckx, Willy; Deleuze, Jean-Paul; Laperre, Jan; Anthonissen, Mieke
2007-08-01
This study investigated the reproducibility of repeated measurements with the Kikuhime pressure sensor under two different types of pressure garments used in the treatment and prevention of scars after burns. Also efficiency of garments was assessed in clinical circumstances by assessing pressure loss and residual pressure after 1 month. Intra- and inter-observer reproducibility and repeated measurements with 1-month time lapse were examined on 55 sites in 26 subjects by means of intra-class correlation coefficients and standard error of measurements. Results showed good to excellent ICC and low SEMs in the two conditions. There was a significant difference in pressure after 1 month between elastic tricot and weft knit garments, although evolution of pressure loss after 1 month was similar. Concerning different locations, there was a significant difference in pressure loss after 1 month between gloves and sleeves with the largest pressure loss for sleeves. Considering these results we concluded that the Kikuhime pressure sensor provides valid and reliable information and can be used in comparative clinical trials to evaluate pressure garments used in burn scar treatment. Secondly, elastic tricot garments in our study tended to have higher clinical pressures but both types of garments had similar pressure loss over time.
A comparison of computer-assisted and manual wound size measurement.
Thawer, Habiba A; Houghton, Pamela E; Woodbury, M Gail; Keast, David; Campbell, Karen
2002-10-01
Accurate and precise wound measurements are a critical component of every wound assessment. To examine the reliability and validity of a new computerized technique for measuring human and animal wounds, chronic human wounds (N = 45) and surgical animal wounds (N = 38) were assessed using manual and computerized techniques. Using intraclass correlation coefficients, intrarater and interrater reliability of surface area measurements obtained using the computerized technique were compared to those obtained using acetate tracings and planimetry. A single measurement of surface area using either technique produced excellent intrarater and interrater reliability for both human and animal wounds, but the computerized technique was more precise than the manual technique for measuring the surface area of animal wounds. For both types of wounds and measurement techniques, intrarater and interrater reliability improved when the average of three repeated measurements was obtained. The precision of each technique with human wounds and the precision of the manual technique with animal wounds also improved when three repeated measurement results were averaged. Concurrent validity between the two techniques was excellent for human wounds but poor for the smaller animal wounds, regardless of whether single or the average of three repeated surface area measurements was used. The computerized technique permits reliable and valid assessment of the surface area of both human and animal wounds.
Fixation-free assessment of the Hirschberg ratio.
Model, Dmitri; Eizenman, Moshe; Sturm, Veit
2010-08-01
To describe a novel methodology by which to measure the Hirschberg ratio (HR) in infants. The methodology does not require fixation on specific points, and measurements are made while infants look naturally at a display. The HR is calculated automatically from measurements of the direction of the optical axis, the position of the pupil center, and corneal reflexes in video images from an advanced two-camera eye-tracking system. The performance of the novel fixation-free procedure (FFP) was evaluated in 43 adults by measuring the average difference and the 95% limits of agreement with the standard fixation-based procedure (FBP). Repeatability of the HR measurements was evaluated by assessing the 95% limits of agreement between two independent measurements. Performance of the FFP was also evaluated in five infants. In adults, the average HR was 12.89 +/- 1.22 degrees/mm for FFP and 12.81 +/- 1.22 degrees/mm for FBP. FFP and FBP measurements were highly correlated (r = 0.95; P < 0.001). The 95% limits of agreement between FFP and FBP were +/-0.86 degrees/mm. The 95% limits of agreement of repeated measurements were +/-0.66 degrees/mm for FFP and +/-0.77 degrees/mm for FBP. In infants, the 95% limits of agreement of repeated measurements by FFP were +/-0.63 degrees/mm. In adults, the FFP provides accurate measurements of the HR that are in excellent agreement with measurements by FBP. In infants, measurements of HR by FFP show the same repeatability and consistency.
7075-T6 and 2024-T351 Aluminum Alloy Fatigue Crack Growth Rate Data
NASA Technical Reports Server (NTRS)
Forth, Scott C.; Wright, Christopher W.; Johnston, William M., Jr.
2005-01-01
Experimental test procedures for the development of fatigue crack growth rate data has been standardized by the American Society for Testing and Materials. Over the past 30 years several gradual changes have been made to the standard without rigorous assessment of the affect these changes have on the precision or variability of the data generated. Therefore, the ASTM committee on fatigue crack growth has initiated an international round robin test program to assess the precision and variability of test results generated using the standard E647-00. Crack growth rate data presented in this report, in support of the ASTM roundrobin, shows excellent precision and repeatability.
Evaluating the Fine Arts Program at the Center for Excellence in Disabilities
ERIC Educational Resources Information Center
Schlosnagle, Leo; McBean, Amanda L.; Cutlip, Milisa; Panzironi, Helen; Jarmolowicz, David P.
2014-01-01
Art programs for people with disabilities may encourage creativity, promote engagement, emphasize inclusion, and extend access and opportunities for community involvement. This mixed methods study utilized quantitative and qualitative data, repeated measures, action research, and stakeholder collaboration to develop and implement an evaluation…
Majeský, Ľuboš; Schwarzacher, Trude; Gornall, Richard; Heslop-Harrison, Pat
2017-01-01
Chloroplast DNA sequences show substantial variation between higher plant species, and less variation within species, so are typically excellent markers to investigate evolutionary, population and genetic relationships and phylogenies. We sequenced the plastomes of Taraxacum obtusifrons Markl. (O978); T. stridulum Trávniček ined. (S3); and T. amplum Markl. (A978), three apomictic triploid (2n = 3x = 24) dandelions from the T. officinale agg. We aimed to characterize the variation in plastomes, define relationships and correlations with the apomictic microspecies status, and refine placement of the microspecies in the evolutionary or phylogenetic context of the Asteraceae. The chloroplast genomes of accessions O978 and S3 were identical and 151,322 bp long (where the nuclear genes are known to show variation), while A978 was 151,349 bp long. All three genomes contained 135 unique genes, with an additional copy of the trnF-GGA gene in the LSC region and 20 duplicated genes in the IR region, along with short repeats, the typical major Inverted Repeats (IR1 and IR2, 24,431bp long), and Large and Small Single Copy regions (LSC 83,889bp and SSC 18,571bp in O978). Between the two Taraxacum plastomes types, we identified 28 SNPs. The distribution of polymorphisms suggests some parts of the Taraxacum plastome are evolving at a slower rate. There was a hemi-nested inversion in the LSC region that is common to Asteraceae, and an SSC inversion from ndhF to rps15 found only in some Asteraceae lineages. A comparative repeat analysis showed variation between Taraxacum and the phylogenetically close genus Lactuca, with many more direct repeats of 40bp or more in Lactuca (1% larger plastome than Taraxacum). When individual genes and non-coding regions were for Asteraceae phylogeny reconstruction, not all showed the same evolutionary scenario suggesting care is needed for interpretation of relationships if a limited number of markers are used. Studying genotypic diversity in plastomes is important to characterize the nature of evolutionary processes in nuclear and cytoplasmic genomes with the different selection pressures, population structures and breeding systems. PMID:28182646
M Salih, Rubar Hussein; Majeský, Ľuboš; Schwarzacher, Trude; Gornall, Richard; Heslop-Harrison, Pat
2017-01-01
Chloroplast DNA sequences show substantial variation between higher plant species, and less variation within species, so are typically excellent markers to investigate evolutionary, population and genetic relationships and phylogenies. We sequenced the plastomes of Taraxacum obtusifrons Markl. (O978); T. stridulum Trávniček ined. (S3); and T. amplum Markl. (A978), three apomictic triploid (2n = 3x = 24) dandelions from the T. officinale agg. We aimed to characterize the variation in plastomes, define relationships and correlations with the apomictic microspecies status, and refine placement of the microspecies in the evolutionary or phylogenetic context of the Asteraceae. The chloroplast genomes of accessions O978 and S3 were identical and 151,322 bp long (where the nuclear genes are known to show variation), while A978 was 151,349 bp long. All three genomes contained 135 unique genes, with an additional copy of the trnF-GGA gene in the LSC region and 20 duplicated genes in the IR region, along with short repeats, the typical major Inverted Repeats (IR1 and IR2, 24,431bp long), and Large and Small Single Copy regions (LSC 83,889bp and SSC 18,571bp in O978). Between the two Taraxacum plastomes types, we identified 28 SNPs. The distribution of polymorphisms suggests some parts of the Taraxacum plastome are evolving at a slower rate. There was a hemi-nested inversion in the LSC region that is common to Asteraceae, and an SSC inversion from ndhF to rps15 found only in some Asteraceae lineages. A comparative repeat analysis showed variation between Taraxacum and the phylogenetically close genus Lactuca, with many more direct repeats of 40bp or more in Lactuca (1% larger plastome than Taraxacum). When individual genes and non-coding regions were for Asteraceae phylogeny reconstruction, not all showed the same evolutionary scenario suggesting care is needed for interpretation of relationships if a limited number of markers are used. Studying genotypic diversity in plastomes is important to characterize the nature of evolutionary processes in nuclear and cytoplasmic genomes with the different selection pressures, population structures and breeding systems.
Rafiee, Banafsheh; Fakhari, Ali Reza
2013-08-15
Nickel oxide nanoparticles modified nafion-multiwalled carbon nanotubes screen printed electrode (NiONPs/Nafion-MWCNTs/SPE) were prepared using pulsed electrodeposition of NiONPs on the MWCNTs/SPE surface. The size, distribution and structure of the NiONPs/Nafion-MWCNTs were characterized by transmission electron microscopy (TEM) and x-ray diffraction (XRD) and also the results show that NiO nanoparticles were homogeneously electrodeposited on the surfaces of MWCNTs. Also, the electrochemical behavior of NiONPs/Nafion-MWCNTs composites in aqueous alkaline solutions of insulin was studied by cyclic voltammetry, chronoamperometry and electrochemical impedance spectroscopy (EIS). It was found that the prepared nanoparticles have excellent electrocatalytic activity towards insulin oxidation due to special properties of NiO nanoparticles. Cyclic voltammetric studies showed that the NiONPs/Nafion-MWCNTs film modified SPE, lowers the overpotentials and improves electrochemical behavior of insulin oxidation, as compared to the bare SPE. Amperometry was also used to evaluate the analytical performance of modified electrode in the quantitation of insulin. Excellent analytical features, including high sensitivity (1.83 μA/μM), low detection limit (6.1 nM) and satisfactory dynamic range (20.0-260.0 nM), were achieved under optimized conditions. Moreover, these sensors show good repeatability and a high stability after a while or successive potential cycling. Copyright © 2013 Elsevier B.V. All rights reserved.
de Andrade, Jucimara Kulek; de Andrade, Camila Kulek; Komatsu, Emy; Perreault, Hélène; Torres, Yohandra Reyes; da Rosa, Marcos Roberto; Felsner, Maria Lurdes
2017-08-01
Corn syrups, important ingredients used in food and beverage industries, often contain high levels of 5-hydroxymethyl-2-furfural (HMF), a toxic contaminant. In this work, an in house validation of a difference spectrophotometric method for HMF analysis in corn syrups was developed using sophisticated statistical tools by the first time. The methodology showed excellent analytical performance with good selectivity, linearity (R 2 =99.9%, r>0.99), accuracy and low limits (LOD=0.10mgL -1 and LOQ=0.34mgL -1 ). An excellent precision was confirmed by repeatability (RSD (%)=0.30) and intermediate precision (RSD (%)=0.36) estimates and by Horrat value (0.07). A detailed study of method precision using a nested design demonstrated that variation sources such as instruments, operators and time did not interfere in the variability of results within laboratory and consequently in its intermediate precision. The developed method is environmentally friendly, fast, cheap and easy to implement resulting in an attractive alternative for corn syrups quality control in industries and official laboratories. Copyright © 2017 Elsevier Ltd. All rights reserved.
Retooling Education: Testing and the Liberal Arts
ERIC Educational Resources Information Center
Jackson, Robert L.
2007-01-01
The motivation and methodology for measuring intelligence have changed repeatedly in the modern history of large-scale student testing. Test makers have always sought to identify raw aptitude for cultivation, but they have never figured out how to promote excellence while preserving equality. They've settled for egalitarianism, which gives rise to…
NASA Astrophysics Data System (ADS)
Alizadeh, Morteza; Khoramkhorshid, Saba; Taghvaei, Amir Hossein; Gokuldoss, Prashanth Konda
2017-07-01
Devitrified Al84Gd6Ni7Co3 glassy particles have been used to reinforce Al-matrix composites through repeated roll bonding (RRB) process. Microstructural characterization of the produced composites after various rolling cycles was performed by scanning electron microscopy. Mechanical properties of the fabricated composites were evaluated by the tensile and microhardness tests. The results indicate that the RRB process is successful to produce composites with the negligible amount of flaws and porosity, and it is followed by homogeneous distribution of Al84Gd6Ni7Co3 particles in the Al matrix after nine rolling passes. Elongation of the composites improves significantly upon RRB cycles and the tensile strength and microhardness of them increase more than two times compared to unreinforced Al. According to fractography results, the enhanced mechanical properties are correlated with formation of excellent bonding at the interface of Al84Gd6Ni7Co3 particles and Al matrix. The theoretical values of composites hardness and yield strength calculated based on iso-strain model show a good agreement with respect to the experimental results.
Pereira, Luísa; Alshamali, Farida; Andreassen, Rune; Ballard, Ruth; Chantratita, Wasun; Cho, Nam Soo; Coudray, Clotilde; Dugoujon, Jean-Michel; Espinoza, Marta; González-Andrade, Fabricio; Hadi, Sibte; Immel, Uta-Dorothee; Marian, Catalin; Gonzalez-Martin, Antonio; Mertens, Gerhard; Parson, Walther; Perone, Carlos; Prieto, Lourdes; Takeshita, Haruo; Rangel Villalobos, Héctor; Zeng, Zhaoshu; Zhivotovsky, Lev; Camacho, Rui; Fonseca, Nuno A
2011-09-01
Because of their sensitivity and high level of discrimination, short tandem repeat (STR) maker systems are currently the method of choice in routine forensic casework and data banking, usually in multiplexes up to 15-17 loci. Constraints related to sample amount and quality, frequently encountered in forensic casework, will not allow to change this picture in the near future, notwithstanding the technological developments. In this study, we present a free online calculator named PopAffiliator ( http://cracs.fc.up.pt/popaffiliator ) for individual population affiliation in the three main population groups, Eurasian, East Asian and sub-Saharan African, based on genotype profiles for the common set of STRs used in forensics. This calculator performs affiliation based on a model constructed using machine learning techniques. The model was constructed using a data set of approximately fifteen thousand individuals collected for this work. The accuracy of individual population affiliation is approximately 86%, showing that the common set of STRs routinely used in forensics provide a considerable amount of information for population assignment, in addition to being excellent for individual identification.
Deployment Testing of Flexible Composite Hinges in Bi-Material Beams
NASA Technical Reports Server (NTRS)
Sauder, Jonathan F.; Trease, Brian
2016-01-01
Composites have excellent properties for strength, thermal stability, and weight. However, they are traditionally highly rigid, and when used in deployable structures require hinges bonded to the composite material, which increases complexity and opportunities for failure. Recent research in composites has found by adding an elastomeric soft matrix, often silicone instead of an epoxy, the composite becomes flexible. This work explores the deployment repeatability of silicone matrix composite hinges which join rigid composite beams. The hinges were found to have sub-millimeter deployment repeatability. Also, an interesting creep effect was discovered, that a hinges deployment error would decrease with time.
First demonstration of olfactory learning and long term memory in honey bee queens.
Gong, Zhiwen; Tan, Ken; Nieh, James C
2018-05-18
As the primary source of colony reproduction, social insect queens play a vital role. However, the cognitive abilities of queens are not well understood, although queen learning and memory are essential in multiple species such as honey bees, in which virgin queens must leave the nest and then successful learn to navigate back over repeated nuptial flights. Honey bee queen learning has never been previously demonstrated. We therefore tested olfactory learning in queens and workers and examined the role of DNA methylation, which plays a key role in long term memory formation. We provide the first evidence that honey bee queens have excellent learning and memory. The proportion of honey bee queens that exhibited learning was 5-fold higher than workers at every tested age and, for memory, 4-fold higher than workers at a very young age. DNA methylation may play a key role in this queen memory because queens exhibiting remote memory had a more consistent elevation in Dnmt3 gene expression as compared to workers. Both castes also showed excellent remote memory (7 day memory), which was reduced by 14-20% by the DNA methylation inhibitor, zebularine. Given that queens live about 10-fold longer than workers, these results suggest that queens can serve as an excellently long-term reservoir of colony memory. © 2018. Published by The Company of Biologists Ltd.
Photometric Repeatability of Scanned Imagery: UVIS
NASA Astrophysics Data System (ADS)
Shanahan, Clare E.; McCullough, Peter; Baggett, Sylvia
2017-08-01
We provide the preliminary results of a study on the photometric repeatability of spatial scans of bright, isolated white dwarf stars with the UVIS channel of the Wide Field Camera 3 (WFC3) on the Hubble Space Telescope (HST). We analyze straight-line scans from the first pair of identical orbits of HST program 14878 to assess if sub 0.1% repeatability can be attained with WFC3/UVIS. This study is motivated by the desire to achieve better signal-to-noise in the UVIS contamination and stability monitor, in which observations of standard stars in staring mode have been taken from the installation of WFC3 in 2009 to the present to assess temporal photometric stability. Higher signal to noise in this program would greatly benefit the sensitivity to detect contamination, and to better characterize the observed small throughput drifts over time. We find excellent repeatability between identical visits of program 14878, with sub 0.1% repeatability achieved in most filters. These! results support the initiative to transition the staring mode UVIS contamination and photometric stability monitor from staring mode images to spatial scans.
Wong, Yu-Tung; Finley, Charles C; Giallo, Joseph F; Buckmire, Robert A
2011-08-01
To introduce a novel method of combining robotics and the CO(2) laser micromanipulator to provide excellent precision and performance repeatability designed for surgical applications. Pilot feasibility study. We developed a portable robotic controller that appends to a standard CO(2) laser micromanipulator. The robotic accuracy and laser beam path repeatability were compared to six experienced users of the industry standard micromanipulator performing the same simulated surgical tasks. Helium-neon laser beam video tracking techniques were employed. The robotic controller demonstrated superiority over experienced human manual micromanipulator control in accuracy (laser path within 1 mm of idealized centerline), 97.42% (standard deviation [SD] 2.65%), versus 85.11% (SD 14.51%), P = .018; and laser beam path repeatability (area of laser path divergence on successive trials), 21.42 mm(2) (SD 4.35 mm(2) ) versus 65.84 mm(2) (SD 11.93 mm(2) ), P = .006. Robotic micromanipulator control enhances accuracy and repeatability for specific laser tasks. Computerized control opens opportunity for alternative user interfaces and additional safety features. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.
Typing Clostridium difficile strains based on tandem repeat sequences
2009-01-01
Background Genotyping of epidemic Clostridium difficile strains is necessary to track their emergence and spread. Portability of genotyping data is desirable to facilitate inter-laboratory comparisons and epidemiological studies. Results This report presents results from a systematic screen for variation in repetitive DNA in the genome of C. difficile. We describe two tandem repeat loci, designated 'TR6' and 'TR10', which display extensive sequence variation that may be useful for sequence-based strain typing. Based on an investigation of 154 C. difficile isolates comprising 75 ribotypes, tandem repeat sequencing demonstrated excellent concordance with widely used PCR ribotyping and equal discriminatory power. Moreover, tandem repeat sequences enabled the reconstruction of the isolates' largely clonal population structure and evolutionary history. Conclusion We conclude that sequence analysis of the two repetitive loci introduced here may be highly useful for routine typing of C. difficile. Tandem repeat sequence typing resolves phylogenetic diversity to a level equivalent to PCR ribotypes. DNA sequences may be stored in databases accessible over the internet, obviating the need for the exchange of reference strains. PMID:19133124
Eerdekens, Maarten; Staes, Filip; Pilkington, Thomas; Deschamps, Kevin
2017-01-01
Application of in-shoe multi-segment foot kinematic analyses currently faces a number of challenges, including: (i) the difficulty to apply regular markers onto the skin, (ii) the necessity for an adequate shoe which fits various foot morphologies and (iii) the need for adequate repeatability throughout a repeated measure condition. The aim of this study therefore was to design novel magnet based 3D printed markers for repeated in-shoe measurements while using accordingly adapted modified shoes for a specific multi-segment foot model. Multi-segment foot kinematics of ten participants were recorded and kinematics of hindfoot, midfoot and forefoot were calculated. Dynamic trials were conducted to check for intra and inter-session repeatability when combining novel markers and modified shoes in a repeated measures design. Intraclass correlation coefficients were calculated to determine reliability. Both repeatability and reliability were proven to be good to excellent with maximum joint angle deviations of 1.11° for intra-session variability and 1.29° for same-day inter-session variability respectively and ICC values of >0.91. The novel markers can be reliably used in future research settings using in-shoe multi-segment foot kinematic analyses with multiple shod conditions.
75 FR 4632 - Voluntary Service National Advisory Committee; Notice of Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-28
... Awards, VAVS Award for Excellence, and the NAC Volunteer of the Year Awards. The April 8 business session... volunteers, cultural transformation, and assisting homeless veterans. On April 9, the educational workshops will be repeated in the morning and the business session will be held in the afternoon and will include...
Chapter 3. Planning and design for habitat monitoring
Christina D. Vojta; Lyman L. McDonald; C. Kenneth Brewer; Kevin S. McKelvey; Mary M Rowland; Michael I. Goldstein
2013-01-01
This chapter provides guidance for designing a habitat monitoring program so that it will meet the monitoring objective, will be repeatable, and will adequately represent habitat within the spatial extent of interest. Although a number of excellent resources are available for planning and designing a monitoring program for wildlife populations (e.g., Busch and Trexler...
USDA-ARS?s Scientific Manuscript database
The economically valuable giant genus Solanum, containing dozens of functional food species such as eggplant and tomato, affords an excellent system to compare and correlate metabolic chemistry with species morphology and evolution. Here, we devised a strategy based on repeatable reversed-phase LC-T...
Humeniuk, Stephan; Büchler, Hans Peter
2017-12-08
We present a method for computing the full probability distribution function of quadratic observables such as particle number or magnetization for the Fermi-Hubbard model within the framework of determinantal quantum Monte Carlo calculations. Especially in cold atom experiments with single-site resolution, such a full counting statistics can be obtained from repeated projective measurements. We demonstrate that the full counting statistics can provide important information on the size of preformed pairs. Furthermore, we compute the full counting statistics of the staggered magnetization in the repulsive Hubbard model at half filling and find excellent agreement with recent experimental results. We show that current experiments are capable of probing the difference between the Hubbard model and the limiting Heisenberg model.
Performance data of the new free-piston shock tunnel at GALCIT
NASA Technical Reports Server (NTRS)
Hornung, Hans G.
1992-01-01
The new free-piston shock tunnel has been partially calibrated, and a range of operating conditions has been found. A large number of difficulties were encountered during the shake-down period, of which the ablation of various parts was the most severe. Solutions to these problems were found. The general principles of high-enthalpy simulation are outlined, and the parameter space covered by T5 is given. Examples of the operating data show that, with care, excellent repeatability may be obtained. The temporal uniformity of the reservoir pressure is very good, even at high enthalpy, because it is possible to operate at tailored-interface and tuned-piston conditions over the whole enthalpy range. Examples of heat transfer and Pitot-pressure measurements are also presented.
Yu, Jia; Yu, Zhichao; Tang, Chenlong
2016-07-04
The hot work environment of electronic components in the instrument cabin of spacecraft was researched, and a new thermal protection structure, namely graphite carbon foam, which is an impregnated phase-transition material, was adopted to implement the thermal control on the electronic components. We used the optimized parameters obtained from ANSYS to conduct 2D optimization, 3-D modeling and simulation, as well as the strength check. Finally, the optimization results were verified by experiments. The results showed that after optimization, the structured carbon-based energy-storing composite material could reduce the mass and realize the thermal control over electronic components. This phase-transition composite material still possesses excellent temperature control performance after its repeated melting and solidifying.
López-Miguel, Alberto; Martínez-Almeida, Loreto; González-García, María J; Coco-Martín, María B; Sobrado-Calvo, Paloma; Maldonado, Miguel J
2013-02-01
To assess the intrasession and intersession precision of ocular, corneal, and internal higher-order aberrations (HOAs) measured using an integrated topographer and Hartmann-Shack wavefront sensor (Topcon KR-1W) in refractive surgery candidates. IOBA-Eye Institute, Valladolid, Spain. Evaluation of diagnostic technology. To analyze intrasession repeatability, 1 experienced examiner measured eyes 9 times successively. To study intersession reproducibility, the same clinician obtained measurements from another set of eyes in 2 consecutive sessions 1 week apart. Ocular, corneal, and internal HOAs were obtained. Coma and spherical aberrations, 3rd- and 4th-order aberrations, and total HOAs were calculated for a 6.0 mm pupil diameter. For intrasession repeatability (75 eyes), excellent intraclass correlation coefficients (ICCs) were obtained (ICC >0.87), except for internal primary coma (ICC = 0.75) and 3rd-order (ICC = 0.72) HOAs. Repeatability precision (1.96 × S(w)) values ranged from 0.03 μm (corneal primary spherical) to 0.08 μm (ocular primary coma). For intersession reproducibility (50 eyes), ICCs were good (>0.8) for ocular primary spherical, 3rd-order, and total higher-order aberrations; reproducibility precision values ranged from 0.06 μm (corneal primary spherical) to 0.21 μm (internal 3rd order), with internal HOAs having the lowest precision (≥0.12 μm). No systematic bias was found between examinations on different days. The intrasession repeatability was high; therefore, the device's ability to measure HOAs in a reliable way was excellent. Under intersession reproducibility conditions, dependable corneal primary spherical aberrations were provided. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Vu, Kim-Nhien; Gilbert, Guillaume; Chalut, Marianne; Chagnon, Miguel; Chartrand, Gabriel; Tang, An
2016-05-01
To assess the agreement between published magnetic resonance imaging (MRI)-based regions of interest (ROI) sampling methods using liver mean proton density fat fraction (PDFF) as the reference standard. This retrospective, internal review board-approved study was conducted in 35 patients with type 2 diabetes. Liver PDFF was measured by magnetic resonance spectroscopy (MRS) using a stimulated-echo acquisition mode sequence and MRI using a multiecho spoiled gradient-recalled echo sequence at 3.0T. ROI sampling methods reported in the literature were reproduced and liver mean PDFF obtained by whole-liver segmentation was used as the reference standard. Intraclass correlation coefficients (ICCs), Bland-Altman analysis, repeated-measures analysis of variance (ANOVA), and paired t-tests were performed. ICC between MRS and MRI-PDFF was 0.916. Bland-Altman analysis showed excellent intermethod agreement with a bias of -1.5 ± 2.8%. The repeated-measures ANOVA found no systematic variation of PDFF among the nine liver segments. The correlation between liver mean PDFF and ROI sampling methods was very good to excellent (0.873 to 0.975). Paired t-tests revealed significant differences (P < 0.05) with ROI sampling methods that exclusively or predominantly sampled the right lobe. Significant correlations with mean PDFF were found with sampling methods that included higher number of segments, total area equal or larger than 5 cm(2) , or sampled both lobes (P = 0.001, 0.023, and 0.002, respectively). MRI-PDFF quantification methods should sample each liver segment in both lobes and include a total surface area equal or larger than 5 cm(2) to provide a close estimate of the liver mean PDFF. © 2015 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Cao, Jiliang; Wang, Chaoxia
2017-05-01
Multifunctional silk fabrics with electrical conductive, anti-ultraviolet and water repellent were successfully prepared by surface modification with graphene oxide (GO). The yellow-brown GO deposited on the surface of silk fabric was converted into graphitic black reduced graphene (RGO) by sodium hydrosulfite. The surface properties of silk fabrics were changed by repeatedly RGO coating process, which have been proved by SEM and XPS. The SEM results showed that the RGO sheets were successive form a continuously thin film on the surface of silk fabrics, and the deposition of GO or RGO also can be proved by XPS. The electrical conductivity was tested by electrical surface resistance value of the silk fabric, the surface resistance decreased with increasing of RGO surface modification times, and a low surface resistance value reached to 3.24 KΩ cm-1 after 9 times of modification, indicating the silk obtained excellent conductivity. The UPF value of one time GO modification silk fabric (silk-1RGO) was enhanced significantly to 24.45 in comparison to 10.40 of original silk. The contact angle of RGO coating silk samples was all above of 120°. The durability of RGO coated silk fabrics was tested by laundering. The electrical surface resistance of silk-4RGO (65.74 KΩ cm-1), silk-6RGO (15.54 KΩ cm-1) and silk-8RGO (3.86 KΩ cm-1) fabrics was up to 86.82, 22.30 and 6.57 KΩ cm-1 after 10 times of standard washing, respectively. The UPF value, contact angle and color differences of RGO modified silk fabric slightly changed before and after 10 times of standard washing. Therefore, the washing fastness of electric conduction, anti-ultraviolet and water repellent multifunctional silk fabrics was excellent.
Investigation of 3D diamond detector dosimetric characteristics
NASA Astrophysics Data System (ADS)
Kanxheri, K.; Alunni Solestizi, L.; Biasini, M.; Caprai, M.; Dipilato, A. C.; Iacco, M.; Ionica, M.; Lagomarsino, S.; Menichelli, M.; Morozzi, A.; Passeri, D.; Sciortino, S.; Talamonti, C.; Zucchetti, C.; Servoli, L.
2018-06-01
Recently, a polycrystalline chemical vapor deposited (pCVD) 3D diamond detector with graphitic in bulk electrodes, fabricated using a pulsed laser technique has been evaluated for photon beam radiation dosimetry during in-air exposure. The same 3D diamond detector, has now been investigated to evaluate its performance under clinically relevant conditions putting the detector inside a Polymethylmethacrylate (PMMA) phantom, to obtain higher precision dosimetric measurements. The detector leakage current was of the order of ± 25 pA or less for bias voltages up to ‑100 V. The 3D detector was tested for time stability and repeatability showing excellent performance with less than 0.6% signal variation. It also showed a linear response for low dose rates with a deviation from linearity of 2%. It was also possible to verify the detector response as a function of the depth in PMMA up to 18 cm.
ImageJ: A Free, Easy, and Reliable Method to Measure Leg Ulcers Using Digital Pictures.
Aragón-Sánchez, Javier; Quintana-Marrero, Yurena; Aragón-Hernández, Cristina; Hernández-Herero, María José
2017-12-01
Wound measurement to document the healing course of chronic leg ulcers has an important role in the management of these patients. Digital cameras in smartphones are readily available and easy to use, and taking pictures of wounds is becoming a routine in specialized departments. Analyzing digital pictures with appropriate software provides clinicians a quick, clean, and easy-to-use tool for measuring wound area. A set of 25 digital pictures of plain foot and leg ulcers was the basis of this study. Photographs were taken placing a ruler next to the wound in parallel with the healthy skin with the iPhone 6S (Apple Inc, Cupertino, CA), which has a camera of 12 megapixels using the flash. The digital photographs were visualized with ImageJ 1.45s freeware (National Institutes of Health, Rockville, MD; http://imagej.net/ImageJ ). Wound area measurement was carried out by 4 raters: head of the department, wound care nurse, physician, and medical student. We assessed intra- and interrater reliability using the interclass correlation coefficient. To determine intraobserver reliability, 2 of the raters repeated the measurement of the set 1 week after the first reading. The interrater model displayed an interclass correlation coefficient of 0.99 with 95% confidence interval of 0.999 to 1.000, showing excellent reliability. The intrarater model of both examiners showed excellent reliability. In conclusion, analyzing digital images of leg ulcers with ImageJ estimates wound area with excellent reliability. This method provides a free, rapid, and accurate way to measure wounds and could routinely be used to document wound healing in daily clinical practice.
Koo, Terry K; Cohen, Jeffrey H; Zheng, Yongping
2011-11-01
Soft tissue exhibits nonlinear stress-strain behavior under compression. Characterizing its nonlinear elasticity may aid detection, diagnosis, and treatment of soft tissue abnormality. The purposes of this study were to develop a rate-controlled Mechano-Acoustic Indentor System and a corresponding finite element optimization method to extract nonlinear elastic parameters of soft tissue and evaluate its test-retest reliability. An indentor system using a linear actuator to drive a force-sensitive probe with a tip-mounted ultrasound transducer was developed. Twenty independent sites at the upper lateral quadrant of the buttock from 11 asymptomatic subjects (7 men and 4 women from a chiropractic college) were indented at 6% per second for 3 sessions, each consisting of 5 trials. Tissue thickness, force at 25% deformation, and area under the load-deformation curve from 0% to 25% deformation were calculated. Optimized hyperelastic parameters of the soft tissue were calculated with a finite element model using a first-order Ogden material model. Load-deformation response on a standardized block was then simulated, and the corresponding area and force parameters were calculated. Between-trials repeatability and test-retest reliability of each parameter were evaluated using coefficients of variation and intraclass correlation coefficients, respectively. Load-deformation responses were highly reproducible under repeated measurements. Coefficients of variation of tissue thickness, area under the load-deformation curve from 0% to 25% deformation, and force at 25% deformation averaged 0.51%, 2.31%, and 2.23%, respectively. Intraclass correlation coefficients ranged between 0.959 and 0.999, indicating excellent test-retest reliability. The automated Mechano-Acoustic Indentor System and its corresponding optimization technique offers a viable technology to make in vivo measurement of the nonlinear elastic properties of soft tissue. This technology showed excellent between-trials repeatability and test-retest reliability with potential to quantify the effects of a wide variety of manual therapy techniques on the soft tissue elastic properties. Copyright © 2011 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
Saengsuwan, Jittima; Berger, Lucia; Schuster-Amft, Corina; Nef, Tobias; Hunt, Kenneth J
2016-09-06
Exercise testing devices for evaluating cardiopulmonary fitness in patients with severe disability after stroke are lacking, but we have adapted a robotics-assisted tilt table (RATT) for cardiopulmonary exercise testing (CPET). Using the RATT in a sample of patients after stroke, this study aimed to investigate test-retest reliability and repeatability of CPET and to prospectively investigate changes in cardiopulmonary outcomes over a period of four weeks. Stroke patients with all degrees of disability underwent 3 separate CPET sessions: 2 tests at baseline (TB1 and TB2) and 1 test at follow up (TF). TB1 and TB2 were at least 24 h apart. TB2 and TF were 4 weeks apart. A RATT equipped with force sensors in the thigh cuffs, a work rate estimation algorithm and a real-time visual feedback system was used to guide the patients' exercise work rate during CPET. Test-retest reliability and repeatability of CPET variables were analysed using paired t-tests, the intraclass correlation coefficient (ICC), the coefficient of variation (CoV), and Bland and Altman limits of agreement. Changes in cardiopulmonary fitness during four weeks were analysed using paired t-tests. Seventeen sub-acute and chronic stroke patients (age 62.7 ± 10.4 years [mean ± SD]; 8 females) completed the test sessions. The median time post stroke was 350 days. There were 4 severely disabled, 1 moderately disabled and 12 mildly disabled patients. For test-retest, there were no statistically significant differences between TB1 and TB2 for most CPET variables. Peak oxygen uptake, peak heart rate, peak work rate and oxygen uptake at the ventilatory anaerobic threshold (VAT) and respiratory compensation point (RCP) showed good to excellent test-retest reliability (ICC 0.65-0.94). For all CPET variables, CoV was 4.1-14.5 %. The mean difference was close to zero in most of the CPET variables. There were no significant changes in most cardiopulmonary performance parameters during the 4-week period (TB2 vs TF). These findings provide the first evidence of test-retest reliability and repeatability of the principal CPET variables using the novel RATT system and testing methodology, and high success rates in identification of VAT and RCP: good to excellent test-retest reliability and repeatability were found for all submaximal and maximal CPET variables. Reliability and repeatability of the main CPET parameters in stroke patients on the RATT were comparable to previous findings in stroke patients using standard exercise testing devices. The RATT has potential to be used as an alternative exercise testing device in patients who have limitations for use of standard exercise testing devices.
Sarkar, Vikramjit; Mukhopadhyay, Balaram
2015-04-10
A linear strategy has been developed for the synthesis of the tetrasaccharide repeating unit of the O-polysaccharide from Azospirillum brasilense SR80. Stepwise glycosylation of the rationally protected thioglycoside donors activated by NIS in the presence of La(OTf)3 furnished the target tetrasaccharide. The glycosylation reactions resulted in the formation of the desired linkage with absolute stereoselectivity and afforded the required derivatives in good to excellent yields. The phthalimido group has been used as the precursor of the desired acetamido group to meet the requirement of 1,2-trans glycosidic linkage. Copyright © 2015 Elsevier Ltd. All rights reserved.
Piezoresistive strain sensing of carbon black /silicone composites above percolation threshold
NASA Astrophysics Data System (ADS)
Shang, Shuying; Yue, Yujuan; Wang, Xiaoer
2016-12-01
A series of flexible composites with a carbon black (CB) filled silicone rubber matrix were made by an improved process in this work. A low percolation threshold with a mass ratio of 2.99% CB was achieved. The piezoresistive behavior of CB/silicone composites above the critical value, with the mass ratio of carbon black to the silicone rubber ranging from 0.01 to 0.2, was studied. The piezoresistive behavior was different from each other for the composites with different CB contents. But, the composites show an excellent repeatability of piezoresistivity under cyclic compression, no matter with low filler content or with high filler content. The most interesting phenomena were that the plots of gauge factor versus strain of the composites with different CB contents constructed a master curve and the curve could be well fitted by a function. It was showed that the gauge factor of the composites was strain-controlled showing a promising prospect of application.
Yang, Xiaohong; Han, Ying; Qi, Meiling; Chen, Chuanfeng
2016-05-06
Unique structures and molecular recognition ability endow iptycene derivatives with great potential as stationary phases in chromatography, which, however, has not been explored yet. Herein, we report the first example of utilizing a pentiptycene quinone (PQ) for gas chromatographic (GC) separations. Remarkably, the statically coated capillary column with the stationary phase achieved extremely high column efficiency of 4800 plates/m. It exhibited preferential retention and high resolving capability for H-bonding and aromatic analytes and positional isomers, showing advantages over the ordinary polysiloxane phase. Moreover, the fabricated iptycene column showed excellent separation repeatability with RSD values of 0.02-0.06% for intra-day, 0.20-0.35% for inter-day and 3.1-5.5% for between-column, respectively. In conclusion, iptycene derivatives as a new class of stationary phases show promising future for their use in GC separations. Copyright © 2016 Elsevier B.V. All rights reserved.
Radiation Resistant Vanadium-Graphene Nanolayered Composite
Kim, Youbin; Baek, Jinwook; Kim, Sunghwan; Kim, Sangmin; Ryu, Seunghwa; Jeon, Seokwoo; Han, Seung Min
2016-01-01
Ultra high strength V-graphene nanolayers were developed for the first time that was demonstrated to have an excellent radiation tolerance as revealed by the He+ irradiation study. Radiation induced hardening, evaluated via nanopillar compressions before and after He+ irradiation, is significantly reduced with the inclusion of graphene layers; the flow stresses of V-graphene nanolayers with 110 nm repeat layer spacing showed an increase of 25% while pure V showed an increase of 88% after He+ dosage of 13.5 dpa. The molecular dynamics simulations confirmed that the graphene interface can spontaneously absorb the nearby crystalline defects that are produced from a collision cascade, thereby enhancing the lifetime of the V-graphene nanolayers via this self-healing effect. In addition, the impermeability of He gas through the graphene resulted in suppression of He bubble agglomerations that in turn reduced embrittlement. In-situ SEM compression also showed the ability of graphene to hinder crack propagation that suppressed the failure. PMID:27098407
Using the Melamine Contamination of Foods to Enhance the Chemistry Classroom
ERIC Educational Resources Information Center
Kimbrough, Doris Renate; Jensen, Anna Chick
2010-01-01
An introduction to the chemistry of the triazine compound, melamine, is presented as well as a brief discussion of the health impacts on humans and pets when melamine contaminates milk products and pet food. Melamine has repeatedly been in the news, and its topical nature provides an excellent springboard for applications of a variety of chemical…
Majidi, Mir Reza; Ghaderi, Seyran
2017-12-01
High surface area nanoporous Cu film (NPCF) has been successfully synthesized using a hydrogen bubble dynamic template on the graphene nanosheets (GNs) modified glassy carbon electrode (GCE). The effect of different synthesis conditions such as applied potential and deposition time on the NPCF morphology was investigated. The structure and constituent of the NPCF-GNs/GCE were characterized by scanning electron microscopy (SEM), energy-dispersive x-ray (EDX), X-ray diffraction (XRD), electrochemical impedance spectroscopy (EIS) and electrochemical methods. The study on electrocatalytic performance of the NPCF-GNs/GCE demonstrated that this electrode has excellent catalytic activity toward nitrite oxidation. The quantitative measurement of nitrite by amperometric method showed a wide concentration range (0.1-100µmolL -1 ) with a detection limit and a sensitivity of 8.87 × 10 -8 molL -1 and 3.1 AL/molcm 2 , respectively. The excellent electrochemical response and high sensitivity of the proposed electrode were attributed to the 3D structure of NPCF and the synergic effect of NPCF and GNs. Furthermore, this electrode showed some other advantages including good repeatability, high reproducibility, long-term stability and anti-interference performance toward nitrite sensing. The applicability of the proposed electrode was proved by successful determination of nitrite in real samples (tap water, river water and sausage samples). Copyright © 2017 Elsevier B.V. All rights reserved.
von Arx, Thomas; Janner, Simone F M; Hänni, Stefan; Bornstein, Michael M
2016-02-01
Conventional 2-dimensional radiography uses defined criteria for outcome assessment of apical surgery. However, these radiographic healing criteria are not applicable for 3-dimensional radiography. The present study evaluated the repeatability and reproducibility of new cone-beam computed tomographic (CBCT)-based healing criteria for the judgment of periapical healing 1 year after apical surgery. CBCT scans taken 1 year after apical surgery (61 roots of 54 teeth in 54 patients, mean age = 54.4 years) were evaluated by 3 blinded and calibrated observers using 4 different indices. Reformatted buccolingual CBCT sections through the longitudinal axis of the treated roots were analyzed. Radiographic healing was assessed at the resection plane (R index), within the apical area (A index), of the cortical plate (C index), and regarding a combined apical-cortical area (B index). All readings were performed twice to calculate the intraobserver agreement (repeatability). Second-time readings were used for analyzing the interobserver agreement (reproducibility). Various statistical tests (Cohen, kappa, Fisher, and Spearman) were performed to measure the intra- and interobserver concurrence, the variability of score ratios, and the correlation of indices. For all indices, the rates of identical first- and second-time scores were always higher than 80% (intraobserver Cohen κ values ranging from 0.793 to 0.963). The B index (94.0%) showed the highest intraobserver agreement. Regarding interobserver agreement, the highest rate was found for the B index (72.1%). The Fleiss' κ values for R and B indices exhibited substantial agreement (0.626 and 0.717, respectively), whereas the values for A and C indices showed moderate agreement (0.561 and 0.573, respectively). The Spearman correlation coefficients for R, A, C, and B indices all exhibited a moderate to very strong correlation with the highest correlation found between C and B indices (rs = 0.8069). All indices showed an excellent intraobserver agreement (repeatability). With regard to interobserver agreement (reproducibility), the B index (healing of apical and cortical defects combined) and the R index (healing on the resection plane) showed substantial congruence and thus are to be recommended in future studies when using buccolingual CBCT sections for radiographic outcome assessment of apical surgery. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Tieqiang; Wang, Shuli; Zhang, Xun; Song, Guoshuai; Yu, Ye; Chen, Xinyang; Fu, Yu; Zhang, Junhu; Yang, Bai
2015-07-01
In this paper, we demonstrate a responsive etalon fabricated through combining colloidal lithography and surface-initiated atom-transfer radical polymerization (SI-ATRP). The responsive etalon is simply constructed with one responsive spacer sandwiched by two reflective layers, and the middle responsive spacer is constructed by grafting thermo-responsive poly(N-isopropylacrylamide) (PNIPAM) brushes on a SiO2 nanosphere array. The etalon possesses one single interference peak in the visible region, and the interference peak changes sensitively against the concentration of the external stimulant (water vapor) or the temperature of the system, owing to the responsiveness of the PNIPAM brush. Importantly, the as-prepared etalon shows a rapid response rate and excellent stability, and it is also handy to realize the miniaturization and integration of the responsive etalon based on a conventional micro-fabrication method. These features all make the as-prepared responsive etalon an attractive candidate for future sensing applications. We believe such responsive etalons are promising for the fabrication of smart photonic materials and optical sensors that may be useful in tissue engineering, medical diagnosis, public security, and biochip areas.
Use of the smartphone for end vertebra selection in scoliosis.
Pepe, Murad; Kocadal, Onur; Iyigun, Abdullah; Gunes, Zafer; Aksahin, Ertugrul; Aktekin, Cem Nuri
2017-03-01
The aim of our study was to develop a smartphone-aided end vertebra selection method and to investigate its effectiveness in Cobb angle measurement. Twenty-nine adolescent idiopathic scoliosis patients' pre-operative posteroanterior scoliosis radiographs were used for end vertebra selection and Cobb angle measurement by standard method and smartphone-aided method. Measurements were performed by 7 examiners. The intraclass correlation coefficient was used to analyze selection and measurement reliability. Summary statistics of variance calculations were used to provide 95% prediction limits for the error in Cobb angle measurements. A paired 2-tailed t test was used to analyze end vertebra selection differences. Mean absolute Cobb angle difference was 3.6° for the manual method and 1.9° for the smartphone-aided method. Both intraobserver and interobserver reliability were found excellent in manual and smartphone set for Cobb angle measurement. Both intraobserver and interobserver reliability were found excellent in manual and smartphone set for end vertebra selection. But reliability values of manual set were lower than smartphone. Two observers selected significantly different end vertebra in their repeated selections for manual method. Smartphone-aided method for end vertebra selection and Cobb angle measurement showed excellent reliability. We can expect a reduction in measurement error rates with the widespread use of this method in clinical practice. Level III, Diagnostic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.
In vivo and in vitro assessment of an intraoral dental colorimeter.
Karaagaclioglu, Lale; Terzioglu, Hakan; Yilmaz, Burak; Yurdukoru, Bengul
2010-06-01
The purpose of this study was to assess the performance of an intraoral dental colorimeter. In vivo repeatability of an intraoral colorimeter was assessed by performing color measurements of 30 individuals' right maxillary central incisor. Three consecutive measurements from each individual were made. In the in vitro part of the study, 25 metal-ceramic and 25 all-ceramic specimens were prepared. Five shades of metal-ceramic and all-ceramic specimens were selected for color determination. A widely recognized in vitro colorimeter was used as the control group for the in vitro performance assessment of the in vivo colorimeter. The color differentiation capability of two colorimeters was compared with the readings obtained from ceramic specimens. DeltaE values between shade groups of ceramic specimens were calculated and statistically analyzed with Student's t-test. The repeatability of the intraoral instrument was evaluated statistically with Intraclass correlation coefficient. The in vivo evaluation results showed that the overall repeatability coefficient values of L*, a*, and b* notations of the intraoral colorimeter were "excellent." The color differences (DeltaE) calculated between the colorimeters were significant only between shades A(1)-B(1) for metal-ceramic specimens (p= 0.002); however, from 5 of 10 shade couples of all-ceramic specimens, the color differences obtained from the readings of the in vivo colorimeter were significantly different from that of the in vitro colorimeter (p < 0.001). For all specimens, the differences between DeltaE values were within clinically acceptable limits (<3.5). Within the limitations of this study, the intraoral colorimeter exhibited successful in vivo repeatability; however, the color difference detection performance of the device varied depending on the translucency of the specimens.
Design and applications of a clamp for Green Fluorescent Protein with picomolar affinity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hansen, Simon; Stüber, Jakob C.; Ernst, Patrick
Green fluorescent protein (GFP) fusions are pervasively used to study structures and processes. Specific GFP-binders are thus of great utility for detection, immobilization or manipulation of GFP-fused molecules. We determined structures of two designed ankyrin repeat proteins (DARPins), complexed with GFP, which revealed different but overlapping epitopes. Here in this paper we show a structure-guided design strategy that, by truncation and computational reengineering, led to a stable construct where both can bind simultaneously: by linkage of the two binders, fusion constructs were obtained that “wrap around” GFP, have very high affinities of about 10–30 pM, and extremely slow off-rates. Theymore » can be natively produced in E. coli in very large amounts, and show excellent biophysical properties. Their very high stability and affinity, facile site-directed functionalization at introduced unique lysines or cysteines facilitate many applications. As examples, we present them as tight yet reversible immobilization reagents for surface plasmon resonance, as fluorescently labelled monomeric detection reagents in flow cytometry, as pull-down ligands to selectively enrich GFP fusion proteins from cell extracts, and as affinity column ligands for inexpensive large-scale protein purification. We have thus described a general design strategy to create a “clamp” from two different high-affinity repeat proteins, even if their epitopes overlap.« less
Design and applications of a clamp for Green Fluorescent Protein with picomolar affinity
Hansen, Simon; Stüber, Jakob C.; Ernst, Patrick; ...
2017-11-24
Green fluorescent protein (GFP) fusions are pervasively used to study structures and processes. Specific GFP-binders are thus of great utility for detection, immobilization or manipulation of GFP-fused molecules. We determined structures of two designed ankyrin repeat proteins (DARPins), complexed with GFP, which revealed different but overlapping epitopes. Here in this paper we show a structure-guided design strategy that, by truncation and computational reengineering, led to a stable construct where both can bind simultaneously: by linkage of the two binders, fusion constructs were obtained that “wrap around” GFP, have very high affinities of about 10–30 pM, and extremely slow off-rates. Theymore » can be natively produced in E. coli in very large amounts, and show excellent biophysical properties. Their very high stability and affinity, facile site-directed functionalization at introduced unique lysines or cysteines facilitate many applications. As examples, we present them as tight yet reversible immobilization reagents for surface plasmon resonance, as fluorescently labelled monomeric detection reagents in flow cytometry, as pull-down ligands to selectively enrich GFP fusion proteins from cell extracts, and as affinity column ligands for inexpensive large-scale protein purification. We have thus described a general design strategy to create a “clamp” from two different high-affinity repeat proteins, even if their epitopes overlap.« less
NASA Astrophysics Data System (ADS)
Clapuyt, Francois; Vanacker, Veerle; Van Oost, Kristof
2016-05-01
Combination of UAV-based aerial pictures and Structure-from-Motion (SfM) algorithm provides an efficient, low-cost and rapid framework for remote sensing and monitoring of dynamic natural environments. This methodology is particularly suitable for repeated topographic surveys in remote or poorly accessible areas. However, temporal analysis of landform topography requires high accuracy of measurements and reproducibility of the methodology as differencing of digital surface models leads to error propagation. In order to assess the repeatability of the SfM technique, we surveyed a study area characterized by gentle topography with an UAV platform equipped with a standard reflex camera, and varied the focal length of the camera and location of georeferencing targets between flights. Comparison of different SfM-derived topography datasets shows that precision of measurements is in the order of centimetres for identical replications which highlights the excellent performance of the SfM workflow, all parameters being equal. The precision is one order of magnitude higher for 3D topographic reconstructions involving independent sets of ground control points, which results from the fact that the accuracy of the localisation of ground control points strongly propagates into final results.
Feng, Juanjuan; Sun, Min; Bu, Yanan; Luo, Chuannan
2015-01-01
A novel nanostructured copper-based solid-phase microextraction fiber was developed and applied for determining the two most common types of phthalate environmental estrogens (dibutyl phthalate and diethylhexyl phthalate) in aqueous samples, coupled to gas chromatography with flame ionization detection. The copper film was coated onto a stainless-steel wire via an electroless plating process, which involved a surface activation process to improve the surface properties of the fiber. Several parameters affecting extraction efficiency such as extraction time, extraction temperature, ionic strength, desorption temperature, and desorption time were optimized by a factor-by-factor procedure to obtain the highest extraction efficiency. The as-established method showed wide linear ranges (0.05-250 μg/L). Precision of single fiber repeatability was <7.0%, and fiber-to-fiber repeatability was <10%. Limits of detection were 0.01 μg/L. The proposed method exhibited better or comparable extraction performance compared with commercial and other lab-made fibers, and excellent thermal stability and durability. The proposed method was applied successfully for the determination of model analytes in plastic soaking water. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Novel Low-Cost Sensor for Human Bite Force Measurement
Fastier-Wooller, Jarred; Phan, Hoang-Phuong; Dinh, Toan; Nguyen, Tuan-Khoa; Cameron, Andrew; Öchsner, Andreas; Dao, Dzung Viet
2016-01-01
This paper presents the design and development of a low cost and reliable maximal voluntary bite force sensor which can be manufactured in-house by using an acrylic laser cutting machine. The sensor has been designed for ease of fabrication, assembly, calibration, and safe use. The sensor is capable of use within an hour of commencing production, allowing for rapid prototyping/modifications and practical implementation. The measured data shows a good linear relationship between the applied force and the electrical resistance of the sensor. The output signal has low drift, excellent repeatability, and a large measurable range of 0 to 700 N. A high signal-to-noise response to human bite forces was observed, indicating the high potential of the proposed sensor for human bite force measurement. PMID:27509496
Optical coherence tomography of the intracranial vasculature and Wingspan stent in a patient
Given, Curtis Alden; Ramsey, Christian Norman; Attizzani, Guilherme Ferragut; Jones, Michael R; Brooks, William H; Bezerra, Hiram G; Costa, Marco A
2014-01-01
Summary A 67-year-old man with medically refractory vertebrobasilar insufficiency and short segment occlusions of the intracranial vertebral arteries was treated with angioplasty and stent placement. Fifteen hours after the procedure the patient developed symptoms of posterior fossa ischemia and repeat angiography showed thrombus formation within the stent which was treated with thrombolytic and aggressive antiplatelet therapy. Angiography revealed lysis of the clot, but concerns regarding the mechanism of the thrombotic phenomenon prompted frequency-domain optical coherence tomography (FDOCT) assessment. FDOCT provided excellent visualization of the stent and vessel wall interactions, as well as excluding residual flow-limiting stenosis, obviating the need for further intervention. The potential utility of FDOCT in the evaluation of intracranial atherosclerotic disease and additional intracranial applications are discussed. PMID:24835808
GDP: A new source for shallow high-resolution seismic exploration
NASA Astrophysics Data System (ADS)
Rashed, Mohamed A.
2009-06-01
Gas-Driven Piston (GDP) is a new source for shallow seismic exploration. This source works by igniting a small amount of gas inside a closed chamber connected to a vertical steel cylinder. The gas explosion drives a steel piston, mounted inside the cylinder, downward so that the piston's thick head hits a steel base at the end of the cylinder generating a strong shock wave into the ground. Experimental field tests conducted near Ismailia, Egypt, prove that the portable, inexpensive and environmentally benign GDP generates stronger seismic waves than the sledgehammer that is commonly used in shallow seismic exploration. Tests also show that GDP is a highly repeatable and controllable and that its seismic waves contain a good amount of high frequencies which makes the GDP an excellent source for shallow seismic exploration.
Enhanced glucose biosensor properties of gold nanoparticle-decorated ZnO nanorods
NASA Astrophysics Data System (ADS)
Wang, Zi-Hao; Yang, Chih-Chiang; Su, Yan-Kuin; Ruand, Jian-Long
2017-04-01
As new materials have been reported and more knowledge on detailed mechanism of glucose oxidation has been unveiled, the non-enzymatic glucose sensor keeps coming closer to practical applications. Nanostructures with higher surface specific area has great potential applications in sensing devices ZnO nanoords were synthesized in a hydrothermal method using simply available laboratory chemicals. Results showed that as-synthesized Gold Nanoparticle-decorated ZnO Nanorods possessing higher specific surface area, significantly increased the non-enzyme efficiency which in turn improved the sensing performances. The electrode also demonstrated excellent performance in sensing glucose concentration with remarkable sensitivity (46.6 μA/mM-cm2) and good repeatability. This work is expected to open a new avenue to fabricate non-enzymatic electrochemical sensors of glucose involving co-mediating.
Discovery of DF-461, a Potent Squalene Synthase Inhibitor
2013-01-01
We report the development of a new trifluoromethyltriazolobenzoxazepine series of squalene synthase inhibitors. Structure–activity studies and pharmacokinetics optimization on this series led to the identification of compound 23 (DF-461), which exhibited potent squalene synthase inhibitory activity, high hepatic selectivity, excellent rat hepatic cholesterol synthesis inhibitory activity, and plasma lipid lowering efficacy in nonrodent repeated dose studies. PMID:24900587
Indexical Relations and Sound Motion Pictures in L2 Curricula: The Dynamic Role of the Teacher
ERIC Educational Resources Information Center
Chen, Liang; Oller, John W., Jr.
2005-01-01
Well-chosen sound motion pictures (SMPs) can be excellent language teaching tools for presenting facts and providing comprehensible input in the target language. They give access to content and authentic surface forms in the target language as well as to the associations between them. SMPs also allow repeated exposures, but they are rarely…
Stoller, Oliver; de Bruin, Eling D; Schindelholz, Matthias; Schuster-Amft, Corina; de Bie, Rob A; Hunt, Kenneth J
2014-10-11
Exercise capacity is seriously reduced after stroke. While cardiopulmonary assessment and intervention strategies have been validated for the mildly and moderately impaired populations post-stroke, there is a lack of effective concepts for stroke survivors suffering from severe motor limitations. This study investigated the test-retest reliability and repeatability of cardiopulmonary exercise testing (CPET) using feedback-controlled robotics-assisted treadmill exercise (FC-RATE) in severely motor impaired individuals early after stroke. 20 subjects (age 44-84 years, <6 month post-stroke) with severe motor limitations (Functional Ambulatory Classification 0-2) were selected for consecutive constant load testing (CLT) and incremental exercise testing (IET) within a powered exoskeleton, synchronised with a treadmill and a body weight support system. A manual human-in-the-loop feedback system was used to guide individual work rate levels. Outcome variables focussed on standard cardiopulmonary performance parameters. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean difference, limits of agreement, and coefficient of variation (CoV) were estimated to assess repeatability. Peak performance parameters during IET yielded good to excellent relative reliability: absolute peak oxygen uptake (ICC =0.82), relative peak oxygen uptake (ICC =0.72), peak work rate (ICC =0.91), peak heart rate (ICC =0.80), absolute gas exchange threshold (ICC =0.91), relative gas exchange threshold (ICC =0.88), oxygen cost of work (ICC =0.87), oxygen pulse at peak oxygen uptake (ICC =0.92), ventilation rate versus carbon dioxide output slope (ICC =0.78). For these variables, SEM was 4-13%, MDC 12-36%, and CoV 0.10-0.36. CLT revealed high mean differences and insufficient test-retest reliability for all variables studied. This study presents first evidence on reliability and repeatability for CPET in severely motor impaired individuals early after stroke using a feedback-controlled robotics-assisted treadmill. The results demonstrate good to excellent test-retest reliability and appropriate repeatability for the most important peak cardiopulmonary performance parameters. These findings have important implications for the design and implementation of cardiovascular exercise interventions in severely impaired populations. Future research needs to develop advanced control strategies to enable the true limit of functional exercise capacity to be reached and to further assess test-retest reliability and repeatability in larger samples.
Repeatability testing of a new Hybrid III 6-year-old ATD lower extremity.
Boucher, Laura C; Ryu, Yeonsu; Kang, Yun-Seok; Bolte, John H
2017-05-29
Vehicle safety is improving, thus decreasing the number of life-threatening injuries and increasing the need for research in other areas of the body. The current child anthropomorphic test device (ATD) does not have the capabilities or instrumentation to measure many of the potential interactions between the lower extremity and the vehicle interior. A prototype Hybrid III 6-year-old ATD lower extremity (ATD-LE) was developed and contains a tibia load cell and a more biofidelic ankle. The repeatability of the device has not yet been assessed; thus, the objective was to evaluate the repeatability of the ATD-LE. Additionally, a dynamic assessment was conducted to quantify injury threshold values. A pneumatic ram impactor was used at 2 velocities to evaluate repeatability. The ATD-LE was fixed to a table and impacted on the plantar aspect of the forefoot. Three repeated trials at 1.3 and 2.3 m/s without shoes and 2.3 m/s with shoes were conducted. The consistency of tibia force (N), bending moment (Nm), ankle range of motion (ROM, °), and stiffness (Nm/°) were quantified. A dynamic assessment using knee bolster airbag (KBA) tests was also conducted. The ATD-LE was positioned to mimic 3 worst-case scenarios: toes touching the mid-dashboard, touching the lower dashboard, and flat on the floor prior to airbag deployment. The impact responses in the femur and tibia were directly collected and compared with published injury threshold values. Ram impact testing indicated primarily excellent repeatability for the variables tested. For all 3 conditions the coefficients of variance (CV) were as follows: tibia force, 1.9-2.7%; tibia moment, 1.0-2.2%; ROM, 1.3-1.4%; ankle stiffness, 4.8-15.6%. The shoe-on condition resulted in a 25% reduction in tibia force and a 56% reduction in tibia bending moment. The KBA tests indicate that the highest injury risk may be when the toes touch the lower dashboard, due to the high bending moments recorded in the tibia at 76.2 Nm, which was above the injury threshold. The above work has demonstrated that the repeatability of the ATD-LE was excellent for tibia force, bending moment, and ankle ROM. The ATD-LE has the ability to provide new information to engineers and researchers due to its ability to directly evaluate the crash response of the ankle and leg. New information on injury mechanism and injury tolerance may lead to injury reduction and thus help advance the safety of children.
Blackledge, Matthew D; Tunariu, Nina; Orton, Matthew R; Padhani, Anwar R; Collins, David J; Leach, Martin O; Koh, Dow-Mu
2016-01-01
Quantitative whole-body diffusion-weighted MRI (WB-DWI) is now possible using semi-automatic segmentation techniques. The method enables whole-body estimates of global Apparent Diffusion Coefficient (gADC) and total Diffusion Volume (tDV), both of which have demonstrated considerable utility for assessing treatment response in patients with bone metastases from primary prostate and breast cancers. Here we investigate the agreement (inter-observer repeatability) between two radiologists in their definition of Volumes Of Interest (VOIs) and subsequent assessment of tDV and gADC on an exploratory patient cohort of nine. Furthermore, each radiologist was asked to repeat his or her measurements on the same patient data sets one month later to identify the intra-observer repeatability of the technique. Using a Markov Chain Monte Carlo (MCMC) estimation method provided full posterior probabilities of repeatability measures along with maximum a-posteriori values and 95% confidence intervals. Our estimates of the inter-observer Intraclass Correlation Coefficient (ICCinter) for log-tDV and median gADC were 1.00 (0.97-1.00) and 0.99 (0.89-0.99) respectively, indicating excellent observer agreement for these metrics. Mean gADC values were found to have ICCinter = 0.97 (0.81-0.99) indicating a slight sensitivity to outliers in the derived distributions of gADC. Of the higher order gADC statistics, skewness was demonstrated to have good inter-user agreement with ICCinter = 0.99 (0.86-1.00), whereas gADC variance and kurtosis performed relatively poorly: 0.89 (0.39-0.97) and 0.96 (0.69-0.99) respectively. Estimates of intra-observer repeatability (ICCintra) demonstrated similar results: 0.99 (0.95-1.00) for log-tDV, 0.98 (0.89-0.99) and 0.97 (0.83-0.99) for median and mean gADC respectively, 0.64 (0.25-0.88) for gADC variance, 0.85 (0.57-0.95) for gADC skewness and 0.85 (0.57-0.95) for gADC kurtosis. Further investigation of two anomalous patient cases revealed that a very small proportion of voxels with outlying gADC values lead to instability in higher order gADC statistics. We therefore conclude that estimates of median/mean gADC and tumour volume demonstrate excellent inter- and intra-observer repeatability whilst higher order statistics of gADC should be used with caution when ascribing significance to clinical changes.
Kliner, Dustin; Wang, Li; Winger, Daniel; Follansbee, William P; Soman, Prem
2015-12-01
Gated single-photon emission computed tomography (SPECT) is widely used for myocardial perfusion imaging and provides an automated assessment of left ventricular ejection fraction (LVEF). We prospectively tested the repeatability of serial SPECT-derived LVEF. This information is essential in order to inform the interpretation of a change in LV function on serial testing. Consenting patients (n = 50) from among those referred for clinically indicated gated myocardial perfusion SPECT (MPs) were recruited. Following the clinical rest-stress study, patients were repositioned on the camera table for a second acquisition using identical parameters. Patient positioning, image acquisition and processing for the second scan were independently performed by a technologist blinded to the clinical scan. Quantitative LVEF was generated by Quantitative Gated SPECT and recorded as EF1 and EF2, respectively. Repeatability of serial results was assessed using the Bland-Altman method. The limits of repeatability and repeatability coefficients were generated to determine the maximum variation in LVEF that can be expected to result from test variability. Repeatability was tested across a broad range of LV systolic function and myocardial perfusion. The mean difference between EF1 and EF2 was 1.6% (EF units), with 95% limits of repeatability of +9.1% to -6.0% (repeatability coefficient 7.5%). Correlation between serial EF measurements was excellent (r = 0.9809). Similar results were obtained in subgroups based on normal or abnormal EF and myocardial perfusion. The largest repeatability coefficient of 8.1% was seen in patients with abnormal LV systolic function. When test protocol and acquisition parameters are kept constant, a difference of >8% EF units on serial MPs is indicative of a true change 95% of the time.
Ultra Lightweight Mirror Fabrication Technology
1983-12-01
supported on-back at three points, 120 degrees apart at the 0.7 radial zone. The surface deformation, produced by a one-g gravity load applied to a...reliable and repeatable simulation of zero- gravity . 16 * ....- • • ~~~~~~. ,. ........ ...... ....... o....... .. -.. . ...... " . - tively... gravity loading. The stability of this mirru, over these environmental conditions is considered to be excellent. The interferometrically measured surface
Development of QCM Trimethylamine Sensor Based on Water Soluble Polyaniline.
Li, Guang; Zheng, Junbao; Ma, Xingfa; Sun, Yu; Fu, Jun; Wu, Gang
2007-10-17
A rapid, sensitive, low-cost device to detect trimethylamine was presented in thispaper. The preparation of water soluble polyaniline was firstly studied. Then the polyanilinewas characterized via Fourier transform infrared spectroscopy (FTIR), UV-visiblespectroscopy and scanning electron microscopy (SEM). Based on the water solublepolyaniline film, a quartz crystal microbalance (QCM) sensor for trimethylamine detectionwas fabricated and its characteristics were examined. The sensor consisted of one quartzcrystal oscillator coated with the polyaniline film for sensing and the other one forreference. Pretreated with trimethylamine, the QCM sensor had an excellent linearsensitivity to trimethylamine. Easily recovered by N2 purgation, the response of the sensorexhibited a good repeatability. Responses of the sensor to trimethylamine, ethanol and ethylacetate were compared, and the results showed that the response was related to the polarityof the analyte vapor. Experimental result also showed that the sensitivity of the sensor wasrelatively stable within one month. The simple and feasible method to prepare and coat thepolyaniline sensing film makes it promising for mass production.
Bio-inspired Edible Superhydrophobic Interface for Reducing Residual Liquid Food.
Li, Yao; Bi, Jingran; Wang, Siqi; Zhang, Tan; Xu, Xiaomeng; Wang, Haitao; Cheng, Shasha; Zhu, Bei-Wei; Tan, Mingqian
2018-03-07
Significant wastage of residual liquid food, such as milk, yogurt, and honey, in food containers has attracted great attention. In this work, a bio-inspired edible superhydrophobic interface was fabricated using U.S. Food and Drug Administration-approved and edible honeycomb wax, arabic gum, and gelatin by a simple and low-cost method. The bio-inspired edible superhydrophobic interface showed multiscale structures, which were similar to that of a lotus leaf surface. This bio-inspired edible superhydrophobic interface displayed high contact angles for a variety of liquid foods, and the residue of liquid foods could be effectively reduced using the bio-inspired interface. To improve the adhesive force of the superhydrophobic interface, a flexible edible elastic film was fabricated between the interface and substrate material. After repeated folding and flushing for a long time, the interface still maintained excellent superhydrophobic property. The bio-inspired edible superhydrophobic interface showed good biocompatibility, which may have potential applications as a functional packaging interface material.
Qu, Jianying; Dong, Ying; Yong, Wang; Lou, Tongfang; Du, Xueping; Qu, Jianhang
2016-03-01
Fe3O4 magnetic nanoparticles were synthesized by chemical co-precipitation with sodium citrate as surfactant and were characterized by FT-IR spectrometer, X-ray diffraction and transmission electron microscopy. A novel nitrite sensor was fabricated by electropolymerization of alizarin red on the surface of glassy carbon electrode modified with Fe3O4-multiwalled carbon nanotubes composite nanofilm. Under the optimal experimental conditions, it was showed that the proposed sensor exhibited good electrocatalytic activity to the oxidation of nitrite, and the peak current increased linearly with the nitrite concentration from 9.64 x 10(-6) mol x L(-1) to 1.30 x 10(-3) mol x L(-1) (R = 0.9976) with a detection limit of 1.19 x 10(-6) mol x L(-1) (S/N = 3). This sensor showed excellent sensitivity, wide linear range, stability and repeatability for nitrite determination with potential applications.
Jia, Jing; Xu, Lili; Wang, Shuai; Wang, Licheng; Liu, Xia
2014-05-01
Nanotubular titania film was prepared in situ on titanium wire and was used as the fiber substrate for solid-phase microextraction (SPME) because of its high surface-to-volume ratio, easy preparation, and mechanical stability. Three different functional coatings, β-cyclodextrin (β-CD), β-cyclodextrin-co-poly(ethylenepropylene glycol) (β-CD/PEG), and polyethylene glycol (PEG)-based sorbents were chemically bonded to the nanostructured wire surface via sol-gel technology to further enhance the absorbing capability and extraction selectivity. Coupled to gas chromatography-flame ionic detection (GC-FID), the prepared SPME fibers were investigated using diverse compounds. The results indicated that the fibers showed good mechanical strength, excellent thermal stability, and wonderful capacity and selectivity to polar compounds, including polar aromatic compounds, alcohols, and ketones. Combining the superior hydrophilic property of a bonded functional molecule and the highly porous structure of a fiber coating, the prepared PEG-coated SPME fiber showed much higher adsorption affinity to ephedrine and methylephedrine than β-CD and β-CD/PEG fibers. The as-established PEG-coated SPME-GC analytical method provided excellent sensitivity (LODs, 0.004 and 0.001 ng mL(-1) for ephedrine and methylephedrine, respectively) and better linear range (0.01-2 000 μg L(-1)). In addition, it has surprising repeatability and reproducibility. Finally, the present approach was used to analyze ephedrine and methylephedrine from real urine samples, and reliable results were obtained.
de Araujo-Barbosa, Paulo Henrique Ferreira; de Menezes, Lidiane Teles; Costa, Abraão Souza; Couto Paz, Clarissa Cardoso Dos Santos; Fachin-Martins, Emerson
2015-05-01
Described as an alternative way of assessing weight-bearing asymmetries, the measures obtained from digital scales have been used as an index to classify weight-bearing distribution. This study aimed to describe the intra-test and the test/retest reliability of measures in subjects with and without hemiparesis during quiet stance. The percentage of body weight borne by one limb was calculated for a sample of subjects with hemiparesis and for a control group that was matched by gender and age. A two-way analysis of variance was used to verify the intra-test reliability. This analysis was calculated using the differences between the averages of the measures obtained during single, double or triple trials. The intra-class correlation coefficient (ICC) was utilized and data plotted using the Bland-Altman method. The intra-test analysis showed significant differences, only observed in the hemiparesis group, between the measures obtained by single and triple trials. Excellent and moderate ICC values (0.69-0.84) between test and retest were observed in the hemiparesis group, while for control groups ICC values (0.41-0.74) were classified as moderate, progressing from almost poor for measures obtained by a single trial to almost excellent for those obtained by triple trials. In conclusion, good reliability ranging from moderate to excellent classifications was found for participants with and without hemiparesis. Moreover, an improvement of the repeatability was observed with fewer trials for participants with hemiparesis, and with more trials for participants without hemiparesis.
NASA Astrophysics Data System (ADS)
Lyu, Shaoyi; Chang, Huanjun; Fu, Feng; Hu, La; Huang, Jingda; Wang, Siqun
2016-09-01
A paper-based wearable supercapacitor with excellent foldability and tailorability is fabricated from a chopped carbon fiber (CCF)-reinforced cellulose paper electrode material by coating with reduced graphene oxide (RGO) and polypyrrole (PPy) via in situ polymerization. The CCFs not only form an interpenetrating conducting network that acts as highly conductive electron transfer highways for the RGO/PPy layer in the paper electrode, but also endow the resulting electrode with an excellent areal capacitance of 363 mF cm-2 and a volumetric energy density of 0.28 mW h cm-3. Further, the CCFs give the electrode remarkable mechanical robustness, guaranteeing foldability and tailorability, with only slight loss of capacitance after repeated folding 600 times. Even after being subjected to severe cut-in fracture, the capacitance retention is up to 84%, indicating outstanding damage tolerance. The present study reveals a promising candidate for flexible wearable energy storage devices that are required to function in harsh environments.
Liu, Weijie; Liu, Nishuang; Yue, Yang; Rao, Jiangyu; Cheng, Feng; Su, Jun; Liu, Zhitian; Gao, Yihua
2018-04-01
Piezoresistive sensor is a promising pressure sensor due to its attractive advantages including uncomplicated signal collection, simple manufacture, economical and practical characteristics. Here, a flexible and highly sensitive pressure sensor based on wrinkled graphene film (WGF)/innerconnected polyvinyl alcohol (PVA) nanowires/interdigital electrodes is fabricated. Due to the synergistic effect between WGF and innerconnected PVA nanowires, the as-prepared pressure sensor realizes a high sensitivity of 28.34 kPa -1 . In addition, the device is able to discern lightweight rice about 22.4 mg (≈2.24 Pa) and shows excellent durability and reliability after 6000 repeated loading and unloading cycles. What is more, the device can detect subtle pulse beat and monitor various human movement behaviors in real-time. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Li, Yu; Milbourn, David
Vanadium microalloying is highly effective in high strength strip steels produced by thin slab casting and direct rolled process. Because of the high solubility of V(C,N) in austenite, vanadium is likely to remain in solution during casting, equalisation and rolling. Vanadium microalloyed steels have better hot ductility and are less prone to transverse cracking than niobium containing steels. Despite a coarse as-cast austenite grain size before rolling, significant grain refinement can be achieved in vanadium microalloyed steels by repeated recrystallization during rolling, resulting in a fine uniform ferrite microstructure in final strip. Almost all vanadium present in microalloyed steels is available to precipitate in ferrite as very fine particles, contributing to precipitation strengthening. Vanadium microalloyed steels show less sensitivity to rolling process variables and exhibit excellent combination of strength and toughness.
NASA Astrophysics Data System (ADS)
Wen, Jiahong; Zhao, Xiaoyu; Li, Qian; Zhang, Sheng; Wang, Dunhui; Du, Youwei
2018-04-01
Multilevel resistance switching (RS) effect has attracted more and more attention due to its promising potential for the increase of storage density in memory devices. In this work, the transport properties are investigated in an Au/La2/3Ba1/3MnO3 (LBMO)/Pt heterostructure. Taking advantage of the strong interplay among the spin, charge, orbital and lattice of LBMO, the Au/LBMO/Pt device can exhibit bipolar RS effect and magnetoresistance effect simultaneously. Under the coaction of electric field and magnetic field, four different resistance states are achieved in this device. These resistance states show excellent repeatability and retentivity and can be switched between any two states, which suggest the potential applications in the multilevel RS memory devices with enhanced storage density.
Rezaei, Babak; Shoushtari, Ahmad Mousavi; Rabiee, Mohammad; Uzun, Lokman; Mak, Wing Cheung; Turner, Anthony P F
2018-05-15
A sandwich-type nanostructured immunosensor based on carboxylated multi-walled carbon nanotube (CMWCNT)-embedded whiskered nanofibres (WNFs) was developed for detection of cardiac Troponin I (cTnI). WNFs were directly fabricated on glassy carbon electrodes (GCE) by removing the sacrificial component (polyethylene glycol, PEG) after electrospinning of polystyrene/CMWCNT/PEG nanocomposite nanofibres, and utilised as a transducer layer for enzyme-labeled amperometric immunoassay of cTnI. The whiskered segments of CMWCNTs were activated and utilised to immobilise anti-cTnT antibodies. It was observed that the anchored CMWCNTs within the nanofibres were suitably stabilised with excellent electrochemical repeatability. A sandwich-type immuno-complex was formed between cTnI and horseradish peroxidase-conjugated anti-cTnI (HRP-anti-cTnI). The amperometric responses of the immunosensor were studied using cyclic voltammetry (CV) through an enzymatic reaction between hydrogen peroxide and HRP conjugated to the secondary antibody. The nanostructured immunosensor delivered a wide detection range for cTnI from the clinical borderline for a normal person (0.5-2ngmL -1 ) to the concentration present in myocardial infarction patients (> 20ngmL -1 ), with a detection limit of ~ 0.04ngmL -1 . It also showed good reproducibility and repeatability for three different cTnI concentration (1, 10 and 25ngmL -1 ) with satisfactory relative standard deviations (RSD). Hence, the proposed nanostructured immunosensor shows potential for point-of-care testing. Copyright © 2018 Elsevier B.V. All rights reserved.
Drug Self-Delivery Systems Based on Hyperbranched Polyprodrugs towards Tumor Therapy.
Duan, Xiao; Chen, Jianxin; Wu, Yalan; Wu, Si; Shao, Dongyan; Kong, Jie
2018-04-16
Amphiphilic hyperbranched polyprodrugs (DOX-S-S-PEG) with drug repeat units in hydrophobic core linked by disulfide bonds were developed as drug self-delivery systems for cancer therapy. The hydroxyl groups and the amine group in doxorubicin (DOX) were linked by 3,3'-dithiodipropanoic acid as hydrophobic hyperbranched cores, then amino-terminated polyethylene glycol monomethyl ether (mPEG-NH 2 ) as hydrophilic shell was linked to hydrophobic cores to form amphiphilic and glutathione (GSH)-responsive micelle of hyperbranched polyprodrugs. The amphiphilic micelles can be disrupted under GSH (1 mg mL -1 ) circumstance. Cell viability of A549 cells and 293T cells was evaluated by CCK-8 and Muse Annexin V & Dead Cell Kit. The disrupted polyprodrugs maintained drug activity for killing tumor cells. Meanwhile, the undisrupted polyprodrugs possessed low cytotoxicity to normal cells. The cell uptake experiments showed that the micelles of DOX-S-S-PEG were taken up by A549 cells and distributed to cell nuclei. Thus, the drug self-delivery systems with drug repeat units in hydrophobic cores linked by disulfide bonds showed significant special advantages: 1) facile one-pot synthesis; 2) completely without toxic or non-degradable polymers; 3) DOX itself functions as fluorescent labeled molecule and self-delivery carrier; 4) drug with inactive form in hyperbranched cores and low cytotoxicity to normal cells. These advantages make them excellent drug self-delivery systems for potential high efficient cancer therapy. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
She, Jiarong; Tian, Cuihua; Wu, Yiqiang; Li, Xianjun; Luo, Sha; Qing, Yan; Jiang, Zheng
2018-06-01
Cellulose nanofibrils (CNFs), disintegrated from natural fibers, are promising alternatives in wastewater purification for the porous structure and numerous hydroxyls. The pristine CNFs aerogel has limited mechanical strength and are vulnerable to collapse when exposed to water. In this work, eco-friendly and recycled CNFs aerogel adsorbents were successfully prepared using cellulose nanofibrils (CNFs), which cross-linked by poly(vinyl alcohol) (PVA) and acrylic acid (AA). The combination of PVA and AA endowed CNFs aerogel strong three-dimensional porous structure and desirable adsorption properties. The heavy metal ions were adsorbed on the CNFs-PVA-AA (CPA) adsorbents efficiently and the maximum adsorption capacities for Cu2+ and Pb2+ approached 30.0 mg/g and 131.5 mg/g, respectively. The CPA adsorbent also showed excellent reusability and their adsorption capacities maintained 89% and 88% for Cu2+ and Pb2+ after 5 repeated uses. The adsorption of these heavy metal ions were confirmed to follow pseudo-second-order kinetic and Langmuir isotherm model. The functions of C ═ O and -OH were the major adsorption sites. Chemical adsorption combined with the porous physical adsorption made the CPA to be excellent adsorbent for the removal of heavy metal ions in wastewater.
Campagna, Giuseppe; Zampetti, Simona; Gallozzi, Alessia; Giansanti, Sara; Chiesa, Claudio; Pacifico, Lucia; Buzzetti, Raffaella
2016-01-01
In a previous study, we found that wrist circumference, in particular its bone component, was associated with insulin resistance in a population of overweight/obese children. The aim of the present study was to evaluate the intra- and inter-operator variability in wrist circumference measurement in a population of obese children and adolescents. One hundred and two (54 male and 48 female) obese children and adolescents were consecutively enrolled. In all subjects wrist circumferences were measured by two different operators two times to assess intra- and inter-operator variability. Statistical analysis was performed using SAS v.9.4 and JMP v.12. Measurements of wrist circumference showed excellent inter-operator reliability with Intra class Correlation Coefficients (ICC) of 0.96 and ICC of 0.97 for the first and the second measurement, respectively. The intra-operator reliability was, also, very strong with a Concordance Correlation Coefficient (CCC) of 0.98 for both operators. The high reproducibility demonstrated in our results suggests that wrist circumference measurement, being safe, non-invasive and repeatable can be easily used in out-patient settings to identify youths with increased risk of insulin-resistance. This can avoid testing the entire population of overweight/obese children for insulin resistance parameters. PMID:27294398
Bi, Liyan; Wang, Yunqing; Yang, Ying; Li, Yuling; Mo, Shanshan; Zheng, Qingyin; Chen, Lingxin
2018-05-09
Conventional research on surface-enhanced Raman scattering (SERS)-based pH sensors often depends on nanoparticle aggregation, whereas the variability in nanoparticle aggregation gives rise to poor repeatability in the SERS signal. Herein, we fabricated a gold nanorod array platform via an efficient evaporative self-assembly method. The platform exhibits great SERS sensitivity with an enhancement factor of 5.6 × 10 7 and maintains excellent recyclability and reproducibility with relative standard deviation (RSD) values of less than 8%. On the basis of the platform, we developed a highly sensitive bovine serum albumin (BSA)-coated 4-mercaptopyridine (4-MPy)-linked (BMP) SERS-based pH sensor to report pH ranging from pH 3.0 to pH 8.0. The intensity ratio variation of 1004 and 1096 cm -1 in 4-MPy showed excellent pH sensitivity, which decreased as the surrounding pH increased. Furthermore, this BMP SERS-based pH sensor was employed to measure the pH value in C57BL/6 mouse blood. We have demonstrated that the pH sensor has great advantages such as good stability, reliability, and accuracy, which could be extended for the design of point-of-care devices.
NASA Astrophysics Data System (ADS)
Li, Beibei; Jiang, Yizhe; Jiang, Fan; Cao, Daxian; Wang, Hongkang; Niu, Chunming
2017-02-01
Bird's nest-like nanographene shell (NGS) encapsulated Si@SiO2 nanoparticles have been prepared by a simple chemical vapor deposition (CVD) method. The shell is comprised of a conformed coating with 4-10 layers of the nanographene, and nanographene spikes with the same thickness grown on the coating surface. The high crystallinity of the shell is demonstrated by XRD, HRTEM and Raman characterization. After SiO2 has been removed, distinctive void space is created between Si core and nested NGS. Statistical estimation from TEM images of 50 Si@void@NGS particles shows that the volume of void space is about 2.82 times of that of Si nanoparticle, sufficient to accommodate volume change from Si to Li15Si4. Evaluation of Si@void@NGS for Li ion anode reveals a specific capacity of 2634 mAh g-1 at a current density of 0.2 A g-1, and an excellent rate and cycling performance. The capacity decreases by 5.2%-2497 mAh g-1 after cycling at current densities of 0.5, 1, 2, 5 10, 20 A g-1. The excellent performance can be attributed to high conductivity and high stability of the shell, which remains intact after repeated cycling.
Pomper, Gregory J; Rick, Margaret E; Epstein, Jay S; Read, Elizabeth J; Leitman, Susan F
2003-11-01
Rare and severe forms of VWD are associated with trace or absent VWF. The feasibility of supporting a child with severe VWD from birth through age 12 with cryoprecipitate derived from DDAVP-stimulated plasma exchange of a single dedicated donor is reported. An infant with excessive hemorrhage at circumcision was found to have Type 3 VWD. His father carried an allele with a mutation at the level of VWF mRNA expression but did not have a history of bleeding. Cryoprecipitate was prepared from serial DDAVP-stimulated plasma exchanges of the father. Repeated plasma-exchange donations were performed to provide all of the VWF needed for his son. An average of 14 cryoprecipitate units was prepared from each donation, and the units contained markedly elevated levels of FVIII:C. The cryoprecipitate was stored for up to 102 months. Components tested after more than 8 years of storage showed 48 to 130 percent of original FVIII:C activity. Ninety-seven percent of the bleeding episodes, such as epistaxis, tongue-biting accidents, and other minor lacerations, were successfully managed with a single 50- to 100-percent replacement dose of FVIII. The patient experienced normal growth and development and is free of any long-term sequelae attributable to his disease. Cryoprecipitate prepared by repeated plasma exchange of a VWD carrier provided excellent hemostatic function, even after storage intervals of more than a year. Plasma exchange of a committed donor was a cost-effective and safe option for long-term management of VWD.
Photocatalytic degradation of diclofenac using TiO2-SnO2 mixed oxide catalysts.
Mugunthan, E; Saidutta, M B; Jagadeeshbabu, P E
2017-12-26
The complex nature of diclofenac limits its biological degradation, posing a serious threat to aquatic organisms. Our present work aims to eliminate diclofenac from wastewater through photocatalytic degradation using TiO 2 -SnO 2 mixed-oxide catalysts under various operating conditions such as catalyst loading, initial diclofenac concentration and initial pH. Different molar ratios of Ti-Sn (1:1, 5:1, 10:1, 20:1 and 30:1) were prepared by the hydrothermal method and were characterized. The results indicated that addition of Sn in small quantity enhances the catalytic activity of TiO 2 . Energy Band gap of the TiO 2 -SnO 2 catalysts was found to increase with an increase in Tin content. TiO 2 -SnO 2 catalyst with a molar ratio of 20:1 was found to be the most effective when compared to other catalysts. The results suggested that initial drug concentration of 20 mg/L, catalyst loading of 0.8 g/L and pH 5 were the optimum operating conditions for complete degradation of diclofenac. Also, the TiO 2 -SnO 2 catalyst was effective in complete mineralization of diclofenac with a maximum total organic carbon removal of 90% achieved under ultraviolet irradiation. The repeatability and stability results showed that the TiO 2 -SnO 2 catalyst exhibited an excellent repeatability and better stability over the repeated reaction cycles. The photocatalytic degradation of diclofenac resulted in several photoproducts, which were identified through LC-MS.
Maximum likelihood decoding analysis of Accumulate-Repeat-Accumulate Codes
NASA Technical Reports Server (NTRS)
Abbasfar, Aliazam; Divsalar, Dariush; Yao, Kung
2004-01-01
Repeat-Accumulate (RA) codes are the simplest turbo-like codes that achieve good performance. However, they cannot compete with Turbo codes or low-density parity check codes (LDPC) as far as performance is concerned. The Accumulate Repeat Accumulate (ARA) codes, as a subclass of LDPC codes, are obtained by adding a pre-coder in front of RA codes with puncturing where an accumulator is chosen as a precoder. These codes not only are very simple, but also achieve excellent performance with iterative decoding. In this paper, the performance of these codes with (ML) decoding are analyzed and compared to random codes by very tight bounds. The weight distribution of some simple ARA codes is obtained, and through existing tightest bounds we have shown the ML SNR threshold of ARA codes approaches very closely to the performance of random codes. We have shown that the use of precoder improves the SNR threshold but interleaving gain remains unchanged with respect to RA code with puncturing.
Study of pre-seismic kHz EM emissions by means of complex systems
NASA Astrophysics Data System (ADS)
Balasis, Georgios; Papadimitriou, Constantinos; Eftaxias, Konstantinos
2010-05-01
The field of study of complex systems holds that the dynamics of complex systems are founded on universal principles that may used to describe disparate problems ranging from particle physics to economies of societies. A corollary is that transferring ideas and results from investigators in hitherto disparate areas will cross-fertilize and lead to important new results. It is well-known that the Boltzmann-Gibbs statistical mechanics works best in dealing with systems composed of either independent subsystems or interacting via short-range forces, and whose subsystems can access all the available phase space. For systems exhibiting long-range correlations, memory, or fractal properties, non-extensive Tsallis statistical mechanics becomes the most appropriate mathematical framework. As it was mentioned a central property of the magnetic storm, solar flare, and earthquake preparation process is the possible occurrence of coherent large-scale collective with a very rich structure, resulting from the repeated nonlinear interactions among collective with a very rich structure, resulting from the repeated nonlinear interactions among its constituents. Consequently, the non-extensive statistical mechanics is an appropriate regime to investigate universality, if any, in magnetic storm, solar flare, earthquake and pre-failure EM emission occurrence. A model for earthquake dynamics coming from a non-extensive Tsallis formulation, starting from first principles, has been recently introduced. This approach leads to a Gutenberg-Richter type law for the magnitude distribution of earthquakes which provides an excellent fit to seismicities generated in various large geographic areas usually identified as "seismic regions". We examine whether the Gutenberg-Richter law corresponding to a non-extensive Tsallis statistics is able to describe the distribution of amplitude of earthquakes, pre-seismic kHz EM emissions (electromagnetic earthquakes), solar flares, and magnetic storms. The analysis shows that the introduced non-extensive model provides an excellent fit to the experimental data, incorporating the characteristics of universality by means of non-extensive statistics into the extreme events under study.
Research@ARL. Imaging & Image Processing. Volume 3, Issue 1
2014-01-01
goal, the focal plane arrays (FPAs) the Army deploys must excel in all areas of performance including thermal sensitivity, image resolution, speed of...are available only in relatively small sizes. Further, the difference in thermal expansion coefficients between a CZT substrate and its silicon (Si...read-out integrated circuitry reduces the reliability of large format FPAs due to repeated thermal cycling. Some in the community believed this
Garcia-Martin, Elena; Pinilla, Isabel; Sancho, Eva; Almarcegui, Carmen; Dolz, Isabel; Rodriguez-Mena, Diego; Fuertes, Isabel; Cuenca, Nicolas
2012-09-01
To evaluate the ability of time-domain and Fourier-domain optical coherence tomographies (OCTs) to detect macular and retinal nerve fiber layer atrophies in retinitis pigmentosa (RP). To test the intrasession reproducibility using three OCT instruments (Stratus, Cirrus, and Spectralis). Eighty eyes of 80 subjects (40 RP patients and 40 healthy subjects) underwent a visual field examination, together with 3 macular scans and 3 optic disk evaluations by the same experienced examiner using 3 OCT instruments. Differences between healthy and RP eyes were compared. The relationship between measurements with each OCT instrument was evaluated. Repeatability was studied by intraclass correlation coefficients and coefficients of variation. Macular and retinal nerve fiber layer atrophies were detected in RP patients for all OCT parameters. Macular and retinal nerve fiber layer thicknesses, as determined by the different OCTs, were correlated but significantly different (P < 0.05). Reproducibility was moderately high using Stratus, good using Cirrus and Spectralis, and excellent using the Tru-track technology of Spectralis. In RP eyes, measurements showed higher variability compared with healthy eyes. Differences in thickness measurements existed between OCT instruments, despite there being a high degree of correlation. Fourier-domain OCT can be considered a valid and repeatability technique to detect retinal nerve fiber layer atrophy in RP patients.
Flexible Lithium-Ion Batteries with High Areal Capacity Enabled by Smart Conductive Textiles.
Ha, Sung Hoon; Shin, Kyu Hang; Park, Hae Won; Lee, Yun Jung
2018-02-05
Increasing demand for flexible devices in various applications, such as smart watches, healthcare, and military applications, requires the development of flexible energy-storage devices, such as lithium-ion batteries (LIBs) with high flexibility and capacity. However, it is difficult to ensure high capacity and high flexibility simultaneously through conventional electrode preparation processes. Herein, smart conductive textiles are employed as current collectors for flexible LIBs owing to their inherent flexibility, fibrous network, rough surface for better adhesion, and electrical conductivity. Conductivity and flexibility are further enhanced by nanosizing lithium titanate oxide (LTO) and lithium iron phosphate (LFP) active materials, and hybridizing them with a flexible 2D graphene template. The resulting LTO/LFP full cells demonstrate high areal capacity and flexibility with tolerance to mechanical fatigue. The battery achieves a capacity of 1.2 mA h cm -2 while showing excellent flexibility. The cells demonstrate stable open circuit voltage retention under repeated flexing for 1000 times at a bending radius of 10 mm. The discharge capacity of the unflexed battery is retained in cells subjected to bending for 100 times at bending radii of 30, 20, and 10 mm, respectively, confirming that the suggested electrode configuration successfully prevents structural damage (delamination or cracking) upon repeated deformation. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Arabi, H; Bendeddouche, I; Khalfaoui, S; Louardi, N; Ameur, A; Lebreton, F; Amarenco, G
2013-04-01
The objective was to translate and linguistically validate in classical Arabic; the French version of the Urinary Symptom Profile (USP), the scale adapted to vesico-sphincter disorders. Prospective study of 30 patients suffering the vesico-sphincter disorders. The translation was obtained by the method: translation back-translation. Patients completed the final questionnaire on day 0 and day 15. The feasibility, acceptability, internal consistency using Cronbach's alpha and test-retest repeatability by the interclass correlation coefficient (ICC) with the confidence interval (CI) were studied. The sample consisted of 30 subjects including 20 men (66.6%) and 10 women (33.3%). The mean age was 48±18, 14 years ranging from 25 to 70 years. The questionnaire was feasible and acceptable. The Cronbach's alpha of the three dimensions, urinary stress incontinence, overactive bladder and voiding difficulties was respectively 0.9880, 0.9774 and 0.9683, respectively; the ICC was 0.9762 (95% CI: 0.9307-0.9919), 0.9558 (CI 95%: 0.8738-0.9849) and 0.9385 (95% CI: 0.8274-0.9789). The Arabic version of the classic USP had excellent internal consistency and excellent repeatability enable a full assessment of all urinary disorders and their severity. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Jones, Alvin
2016-05-01
This research examined cutoff scores for the Effort Index (EI), an embedded measure of performance validity, for the Repeatable Battery for the Assessment of Neuropsychological Status. EI cutoffs were explored for an active-duty military sample composed mostly of patients with traumatic brain injury. Four psychometrically defined malingering groups including a definite malingering, probable to definite malingering, probable malingering, and a combined group were formed based on the number of validity tests failed. Excellent specificities (0.97 or greater) were found for all cutoffs examined (EI ≥ 1 to EI ≥ 3). Excellent sensitivities (0.80 to 0.89) were also found for the definite malingering group. Sensitivities were 0.49 or below for the other groups. Positive and negative predictive values and likelihood ratios indicated that the cutoffs for EI were much stronger for ruling-in than ruling-out malingering. Analyses indicated the validity tests used to form the malingering groups were uncorrelated, which serves to enhance the validity of the formation of the malingering groups. Cutoffs were similar to other research using samples composed predominantly of head-injured individuals. Published by Oxford University Press 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Fakhri, Georges El
2011-01-01
82Rb cardiac PET allows the assessment of myocardial perfusion using a column generator in clinics that lack a cyclotron. We and others have previously shown that quantitation of myocardial blood flow (MBF) and coronary flow reserve (CFR) is feasible using dynamic 82Rb PET and factor and compartment analyses. The aim of the present work was to determine the intra- and inter-observer variability of MBF estimation using 82Rb PET as well as the reproducibility of our generalized factor + compartment analyses methodology to estimate MBF and assess its accuracy by comparing, in the same subjects, 82Rb estimates of MBF to those obtained using 13N-ammonia. Methods Twenty-two subjects were included in the reproducibility and twenty subjects in the validation study. Patients were injected with 60±5mCi of 82Rb and imaged dynamically for 6 minutes at rest and during dipyridamole stress Left and right ventricular (LV+RV) time-activity curves were estimated by GFADS and used as input to a 2-compartment kinetic analysis that estimates parametric maps of myocardial tissue extraction (K1) and egress (k2), as well as LV+RV contributions (fv,rv). Results Our results show excellent reproducibility of the quantitative dynamic approach itself with coefficients of repeatability of 1.7% for estimation of MBF at rest, 1.4% for MBF at peak stress and 2.8% for CFR estimation. The inter-observer reproducibility between the four observers that participated in this study was also very good with correlation coefficients greater than 0.87 between any two given observers when estimating coronary flow reserve. The reproducibility of MBF in repeated 82Rb studies was good at rest and excellent at peak stress (r2=0.835). Furthermore, the slope of the correlation line was very close to 1 when estimating stress MBF and CFR in repeated 82Rb studies. The correlation between myocardial flow estimates obtained at rest and during peak stress in 82Rb and 13N-ammonia studies was very good at rest (r2=0.843) and stress (r2=0.761). The Bland-Altman plots show no significant presence of proportional error at rest or stress, nor a dependence of the variations on the amplitude of the myocardial blood flow at rest or stress. A small systematic overestimation of 13N-ammonia MBF was observed with 82Rb at rest (0.129 ml/g/min) and the opposite, i.e., underestimation, at stress (0.22 ml/g/min). Conclusions Our results show that absolute quantitation of myocardial bloof flow is reproducible and accurate with 82Rb dynamic cardiac PET as compared to 13N-ammonia. The reproducibility of the quantitation approach itself was very good as well as inter-observer reproducibility. PMID:19525467
Al-Amri, Mohammad; Al Balushi, Hilal; Mashabi, Abdulrhman
2017-12-01
Self-paced treadmill walking is becoming increasingly popular for the gait assessment and re-education, in both research and clinical settings. Its day-to-day repeatability is yet to be established. This study scrutinised the test-retest repeatability of key gait parameters, obtained from the Gait Real-time Analysis Interactive Lab (GRAIL) system. Twenty-three male able-bodied adults (age: 34.56 ± 5.12 years) completed two separate gait assessments on the GRAIL system, separated by 5 ± 3 days. Key gait kinematic, kinetic, and spatial-temporal parameters were analysed. The Intraclass-Correlation Coefficients (ICC), Standard Error Measurement (SEM), Minimum Detectable Change (MDC), and the 95% limits of agreements were calculated to evaluate the repeatability of these gait parameters. Day-to-day agreements were excellent (ICCs > 0.87) for spatial-temporal parameters with low MDC and SEM values, <0.153 and <0.055, respectively. The repeatability was higher for joint kinetic than kinematic parameters, as reflected in small values of SEM (<0.13 Nm/kg and <3.4°) and MDC (<0.335 Nm/kg and <9.44°). The obtained values of all parameters fell within the 95% limits of agreement. Our findings demonstrate the repeatability of the GRAIL system available in our laboratory. The SEM and MDC values can be used to assist researchers and clinicians to distinguish 'real' changes in gait performance over time.
Ali Eissa, Ali A; Reyad, Raafat M; Saleh, Emad G; El-Saman, Amr
2015-10-01
We conducted a retrospective study to evaluate the efficacy and duration of pain relief for idiopathic trigeminal neuralgia (TN) patients after continuous radiofrequency (CRF) combined with pulsed radiofrequency (PRF) treatment of the Gasserian ganglion (GG). Twenty-one patients were treated with pulsed RF for 6 min repeated after rotating the needle tip by 180°, at a pulse width of 10 ms and at 45 °C. This was followed by conventional RF at 60 °C for 60 s, repeated after needle rotation by 180°, then finally at 65 °C for 60 s also repeated after needle rotation by 180°. Patients were assessed for pain intensity and consumption of analgesics at baseline and 7 days, 1 month, 6 months, and 12 months after the procedure. The patients' global impression of change (PGIC) scale was also assessed 7 days, 1 month, 6 months, and 12 months after the procedure. The incidence of facial dysthesia was evaluated 7 days after the procedure. Excellent pain relief was achieved for 15 of 21 patients (71.4 %) after 1 week, 1 month, and 6 months. and for 14 of 21 patients (66.7 %) after 12 months. Consumption of analgesics was significantly reduced for more than 6 months, and for fifteen patients the PGIC scale result was very much improved 12 months after the procedure compared with baseline. Eighteen of the 21 patients (85.7 %) experienced facial dysthesia 1 week after the procedure. Excellent pain relief and reduced consumption of analgesics for more than 6 months were observed in patients who received PRF combined with CRF to the GG for treatment of idiopathic TN.
Costa, M P; Balthazar, C F; Franco, R M; Mársico, E T; Cruz, A G; Conte, C A
2014-05-01
Goat milk yogurt is an excellent source of fatty acids, protein, and minerals; however, it is not well accepted by many consumers, due to its typical flavor derived from caprylic, capric, and caproic acids present in this milk and dairy products. Recently, the repeated-exposure test has been used to increase the consumption of particular foods. This methodology has been used to increase children's willingness to eat food in some settings and has also been used to reduce sodium in soup. Based on these considerations, the aim of this study was to investigate whether repeated exposures may increase acceptance of both goat milk yogurt and probiotic goat milk yogurt. In a pre-exposure session, a total of 45 panelists (28 females and 17 males) from southeastern Brazil, who were not used to consuming dairy goat milk, evaluated the expected taste perception and the perceived liking after tasting 3 yogurt preparations. Then, consumers were randomly divided into 3 groups and participated in rapidly repeated exposure sessions performed within 6 d. Each panelist consumed only the yogurt that he or she would be exposed to. The day after the exposure sessions, all panelists returned to participate in the postexposure session and were asked to evaluate acceptance, familiarity, and the "goaty taste" characteristic of each yogurt. Regarding the expected liking before tasting, results showed higher expectations for cow milk yogurt compared with goat milk yogurt, which proved that consumers were not familiar with the goat milk yogurt. Likewise, only cow milk yogurt presented high acceptance and familiarity rates, confirming that these panelists were used to consuming cow milk products. With respect to the rapidly repeated exposure, 6 d were enough to significantly increase the consumers' familiarity with goat milk yogurt and probiotic goat milk yogurt. However, this method was not suitable to significantly increase the acceptance of such products. Nonetheless, a correlation existed between the exposure sessions and the increase in acceptance of the exposure groups. Thus, hypothetically, the increasing of exposure sessions could be a strategy to increase goat milk product acceptance. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Stretchable Platinum Network-Based Transparent Electrodes for Highly Sensitive Wearable Electronics.
Wang, Yuting; Cheng, Jing; Xing, Yan; Shahid, Muhammad; Nishijima, Hiroki; Pan, Wei
2017-07-01
A platinum network-based transparent electrode has been fabricated by electrospinning. The unique nanobelt structured electrode demonstrates low sheet resistance (about 16 Ω sq -1 ) and high transparency of 80% and excellent flexibility. One of the most interesting demonstrations of this Pt nanobelt electrode is its excellent reversibly resilient characteristic. The electric conductivity of the flexible Pt electrode can recover to its initial value after 160% extending and this performance is repeatable and stable. The good linear relationship between the resistance and strain of the unique structured Pt electrode makes it possible to assemble a wearable high sensitive strain sensor. Present reported Pt nanobelt electrode also reveals potential applications in electrode for flexible fuel cells and highly transparent ultraviolet (UV) sensors. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Issa, Kimona; Pierce, Todd P; Brothers, Alexander; McInerney, Vincent K; Chughtai, Morad; Mistry, Jaydev B; Bryant, Wayne W; Delanois, Ronald E; Harwin, Steven F; Mont, Michael A
2016-04-01
Manipulation under anesthesia (MUA) can help post-total knee arthroplasty (TKA) patients who have knee stiffness regain range-of-motion. However, despite undergoing MUA, patients may have persistent knee stiffness. Often, this persistent knee stiffness is treated with a repeat MUA. Therefore, the purpose of this study was to evaluate repeat MUAs by assessing: (1) demographic characteristics, (2) range-of-motion, (3) clinical outcomes, and (4) rate of revision surgery in post-TKA patients with persistent knee stiffness who either underwent a single MUA or repeat MUAs. One-hundred-and-sixty-seven post-TKA who had undergone an MUA between 2005 and 2011 at two institutions were reviewed. Patients were stratified into those who had a single-MUA (138 knees) and those who had a repeat MUA (29 knees). The mean follow-up period was 63 months (range, 36 to 90 months). The incidence of repeat MUA within this cohort was determined. Demographics and ROM were compared using Student t-test and Chi-square as appropriate. Functional outcomes were assessed using Knee Society scores (KSS) and compared between the two cohorts. Among the 167 patients who underwent a MUA, 29 (17%) required repeat manipulations. The repeat MUA cohort was younger and more likely to have osteonecrosis as the underlying cause of knee disease. For the repeat MUA cohort, 17 patients (59%) had achieved satisfactory mean gains in ROM after their repeat MUAs. These patients had also achieved excellent mean Knee Society objective and functional scores. However, another seven knees (24%) had further persistent knee stiffness requiring arthrolysis of adhesions and five patients (17%) had undergone revision of the polyethylene spacer or patellar component to improve range-of-motion. In this study, the majority of patients who had undergone a repeat MUA were able to achieve improvements in flexion range-of-motion and functional outcomes. However, the remaining patients required more invasive procedure to treat persistent knee stiffness. In patients who have persistent knee stiffness after MUAs, a repeat MUA may be helpful to increase range-of-motion and function.
Kunert, Kathleen S; Peter, Monika; Blum, Marcus; Haigis, Wolfgang; Sekundo, Walter; Schütze, Juliane; Büehren, Tobias
2016-01-01
To estimate the repeatability of biometric parameters obtained with a new swept-source biometer and to compare the agreement with that of partial coherence interferometry (PCI) and optical low-coherence reflectometry (OLCR). Department of Ophthalmology, Helios Hospital Erfurt, Erfurt, Julius-Maximilians University, Würzburg, and Philipps University, Marburg, Germany. Prospective comparative multicenter clinical study. Biometry was taken with the use of 3 different biometers: the IOLMaster 700 swept-source biometer, the PCI-based IOLMaster 500, and the OCLR-based Lenstar LS 900. Axial length (AL), anterior chamber depth (ACD), and spherical equivalent (SE) were compared between swept-source and PCI biometry and central corneal thickness (CCT) and lens thickness (LT) between swept-source and OLCR biometry. The repeatability of swept-source biometry was evaluated on the basis of 3 measurements captured for each patient. One hundred twenty cataract eyes were included in the study. The mean difference between swept-source and PCI biometry for AL, ACD, and SE measurements was 4 μm ± 25 (SD), 17 ± 122 μm, and -0.001 ± 0.19 diopter (D), respectively. The mean difference between swept-source and OLCR biometry for LT and CCT measurements was 21 ± 122 μm and 0.15 ± 4.51 μm, respectively. Differences between swept-source biometry and the other devices distributed around zero without statistical significance. The standard deviation of repeatability for AL, ACD, LT, CCT, and SE was 8.8 μm, 9.8 μm, 2.3 μm, 19.5 μm, and 0.1 D, respectively. Swept-source biometry showed high repeatability performance for all biometric parameters. The agreement of AL, ACD, and SE between swept-source and PCI biometry as well as that of LT and CCT between swept-source and OLCR biometry was excellent. It remains to be validated whether high repeatability shown by swept-source biometry will result in better postoperative refractive outcomes. Drs. Blum and Sekundo are members of the Scientific Advisory Board of Carl Zeiss Meditec AG. Drs. Peter and Bühren are employees of Carl Zeiss Meditec AG. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Hoenig, Helen M; Amis, Kristopher; Edmonds, Carol; Morgan, Michelle S; Landerman, Lawrence; Caves, Kevin
2017-01-01
Background There is limited research about the effects of video quality on the accuracy of assessments of physical function. Methods A repeated measures study design was used to assess reliability and validity of the finger-nose test (FNT) and the finger-tapping test (FTT) carried out with 50 veterans who had impairment in gross and/or fine motor coordination. Videos were scored by expert raters under eight differing conditions, including in-person, high definition video with slow motion review and standard speed videos with varying bit rates and frame rates. Results FTT inter-rater reliability was excellent with slow motion video (ICC 0.98-0.99) and good (ICC 0.59) under the normal speed conditions. Inter-rater reliability for FNT 'attempts' was excellent (ICC 0.97-0.99) for all viewing conditions; for FNT 'misses' it was good to excellent (ICC 0.89) with slow motion review but substantially worse (ICC 0.44) on the normal speed videos. FTT criterion validity (i.e. compared to slow motion review) was excellent (β = 0.94) for the in-person rater and good ( β = 0.77) on normal speed videos. Criterion validity for FNT 'attempts' was excellent under all conditions ( r ≥ 0.97) and for FNT 'misses' it was good to excellent under all conditions ( β = 0.61-0.81). Conclusions In general, the inter-rater reliability and validity of the FNT and FTT assessed via video technology is similar to standard clinical practices, but is enhanced with slow motion review and/or higher bit rate.
Clément, Julien; Raison, Maxime; Rouleau, Dominique M
2018-02-08
None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, particularly in terms of reproducibility. Therefore, this study aims to evaluate the reproducibility of the reachable workspace over a period of several weeks, and to assess the effects of two proposed acquisition protocols, as well as those of gender, and hand dominancy. Shoulder movements were recorded using a motion capture system on 10 female and 10 male healthy subjects during a random protocol, i.e. simply asking them to achieve the farthest points they could reach with their hands, and during a standardized protocol, i.e. asking them to perform predefined shoulder elevations while keeping their trunk and elbow straight. The standardized protocol was repeated 7 weeks later. Repeated measures showed no significant difference, good to excellent intraclass correlation coefficients (0.46-0.81) and small bias (0.0-1.2%). The random protocol provided significantly lower and more scattered values for the reachable workspace (80.0 ± 22.6% vs. 91.0 ± 8.1%, p = .004), whereas gender and hand-dominancy had no effect. This study showed that the reachable workspace was highly reliable over a period of 7 weeks and that both upper limbs provided similar results. It could be used to monitor various pathologies of the upper limbs and to assess treatment efficiency, using a subject's healthy limb as reference. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kinetics of Semiconductor Surface Chemistry: Silicon Atomic Layer Processing
1993-05-01
H20 --> Si-OH + HCI; and (B) Si-OH + SiCl4 -- > Si-O-SiCl 3 + HC1. We examined reaction (A) for SiO 2 growth on Si(111)7x7 and porous silicon and... SiCl4 > Si-O-SiCl3 + HCI Repeat... • Reaction (A) and (B) are self-limiting * Expect excellent conformality Si-Cl + H20 ->Si-OH + HC1 SiCl2 LITD
Forte, Antonio Elia; Etard, Octave; Reichenbach, Tobias
2017-10-10
Humans excel at selectively listening to a target speaker in background noise such as competing voices. While the encoding of speech in the auditory cortex is modulated by selective attention, it remains debated whether such modulation occurs already in subcortical auditory structures. Investigating the contribution of the human brainstem to attention has, in particular, been hindered by the tiny amplitude of the brainstem response. Its measurement normally requires a large number of repetitions of the same short sound stimuli, which may lead to a loss of attention and to neural adaptation. Here we develop a mathematical method to measure the auditory brainstem response to running speech, an acoustic stimulus that does not repeat and that has a high ecological validity. We employ this method to assess the brainstem's activity when a subject listens to one of two competing speakers, and show that the brainstem response is consistently modulated by attention.
Palomino Cabello, Carlos; Arean, Carlos Otero; Parra, José B; Ania, Conchi O; Rumori, P; Turnes Palomino, G
2015-06-07
We report on a facile and rapid microwave-assisted method for preparing a sodium-cadmium metal-organic framework (having coordinatively unsaturated sodium ions) that considerably shortens the conventional synthesis time from 5 days to 1 hour. The obtained (Na,Cd)-MOF showed an excellent volumetric CO2 adsorption capacity (5.2 mmol cm(-3) at 298 K and 1 bar) and better CO2 adsorption properties than those shown by the same metal-organic framework when synthesized following a more conventional procedure. Moreover, the newly prepared material was found to display high selectivity for adsorption of carbon dioxide over nitrogen, and good regenerability and stability during repeated CO2 adsorption-desorption cycles, which are the required properties for any adsorbent intended for carbon dioxide capture and sequestration (CSS) from the post-combustion flue gas of fossil fuelled power stations.
Thermochromic halide perovskite solar cells.
Lin, Jia; Lai, Minliang; Dou, Letian; Kley, Christopher S; Chen, Hong; Peng, Fei; Sun, Junliang; Lu, Dylan; Hawks, Steven A; Xie, Chenlu; Cui, Fan; Alivisatos, A Paul; Limmer, David T; Yang, Peidong
2018-03-01
Smart photovoltaic windows represent a promising green technology featuring tunable transparency and electrical power generation under external stimuli to control the light transmission and manage the solar energy. Here, we demonstrate a thermochromic solar cell for smart photovoltaic window applications utilizing the structural phase transitions in inorganic halide perovskite caesium lead iodide/bromide. The solar cells undergo thermally-driven, moisture-mediated reversible transitions between a transparent non-perovskite phase (81.7% visible transparency) with low power output and a deeply coloured perovskite phase (35.4% visible transparency) with high power output. The inorganic perovskites exhibit tunable colours and transparencies, a peak device efficiency above 7%, and a phase transition temperature as low as 105 °C. We demonstrate excellent device stability over repeated phase transition cycles without colour fade or performance degradation. The photovoltaic windows showing both photoactivity and thermochromic features represent key stepping-stones for integration with buildings, automobiles, information displays, and potentially many other technologies.
Thermochromic halide perovskite solar cells
NASA Astrophysics Data System (ADS)
Lin, Jia; Lai, Minliang; Dou, Letian; Kley, Christopher S.; Chen, Hong; Peng, Fei; Sun, Junliang; Lu, Dylan; Hawks, Steven A.; Xie, Chenlu; Cui, Fan; Alivisatos, A. Paul; Limmer, David T.; Yang, Peidong
2018-03-01
Smart photovoltaic windows represent a promising green technology featuring tunable transparency and electrical power generation under external stimuli to control the light transmission and manage the solar energy. Here, we demonstrate a thermochromic solar cell for smart photovoltaic window applications utilizing the structural phase transitions in inorganic halide perovskite caesium lead iodide/bromide. The solar cells undergo thermally-driven, moisture-mediated reversible transitions between a transparent non-perovskite phase (81.7% visible transparency) with low power output and a deeply coloured perovskite phase (35.4% visible transparency) with high power output. The inorganic perovskites exhibit tunable colours and transparencies, a peak device efficiency above 7%, and a phase transition temperature as low as 105 °C. We demonstrate excellent device stability over repeated phase transition cycles without colour fade or performance degradation. The photovoltaic windows showing both photoactivity and thermochromic features represent key stepping-stones for integration with buildings, automobiles, information displays, and potentially many other technologies.
Organic bistable memory devices based on MoO3 nanoparticle embedded Alq3 structures.
Abhijith, T; Kumar, T V Arun; Reddy, V S
2017-03-03
Organic bistable memory devices were fabricated by embedding a thin layer of molybdenum trioxide (MoO 3 ) between two tris-(8-hydroxyquinoline)aluminum (Alq 3 ) layers. The device exhibited excellent switching characteristics with an ON/OFF current ratio of 1.15 × 10 3 at a read voltage of 1 V. The device showed repeatable write-erase capability and good stability in both the conductance states. These conductance states are non-volatile in nature and can be obtained by applying appropriate voltage pulses. The effect of MoO 3 layer thickness and its location in the Alq 3 matrix on characteristics of the memory device was investigated. The field emission scanning electron microscopy (FE-SEM) images of the MoO 3 layer revealed the presence of isolated nanoparticles. Based on the experimental results, a mechanism has been proposed for explaining the conductance switching of fabricated devices.
Cryogenic temperature effects on sting-balance deflections in the National Transonic Facility
NASA Technical Reports Server (NTRS)
Popernack, Thomas G., Jr.; Adcock, Jerry B.
1990-01-01
An investigation was conducted at the National Transonic Facility (NTF) to document the change in sting-balance deflections from ambient to cryogenic temperatures. Space limitations in some NTF models do not allow the use of on-board angle of attack instrumentation. In order to obtain angle of attack data, pre-determined sting-balance bending data must be combined with arc sector angle measurements. Presently, obtaining pretest sting-balance data requires several cryogenic cycles and cold loadings over a period of several days. A method of reducing the calibration time required is to obtain only ambient temperature sting-balance bending data and correct for changes in material properties at cryogenic temperatures. To validate this method, two typical NTF sting-balance combinations were tested. The test results show excellent agreement with the predicted values and the repeatability of the data was 0.01 degree.
Pose estimation of teeth through crown-shape matching
NASA Astrophysics Data System (ADS)
Mok, Vevin; Ong, Sim Heng; Foong, Kelvin W. C.; Kondo, Toshiaki
2002-05-01
This paper presents a technique for determining a tooth's pose given a dental plaster cast and a set of generic tooth models. The ultimate goal of pose estimation is to obtain information about the sizes and positions of the roots, which lie hidden within the gums, without the use of X-rays, CT or MRI. In our approach, the tooth of interest is first extracted from the 3D dental cast image through segmentation. 2D views are then generated from the extracted tooth and are matched against a target view generated from the generic model with known pose. Additional views are generated in the vicinity of the best view and the entire process is repeated until convergence. Upon convergence, the generic tooth is superimposed onto the dental cast to show the position of the root. The results of applying the technique to canines demonstrate the excellent potential of the algorithm for generic tooth fitting.
High performance flexible pH sensor based on polyaniline nanopillar array electrode.
Yoon, Jo Hee; Hong, Seok Bok; Yun, Seok-Oh; Lee, Seok Jae; Lee, Tae Jae; Lee, Kyoung G; Choi, Bong Gill
2017-03-15
Flexible pH sensor technologies have attracted a great deal of attention in many applications, such as, wearable health care devices and monitors for chemical and biological processes. Here, we fabricated flexible and thin pH sensors using a two electrode configuration comprised of a polyaniline nanopillar (PAN) array working electrode and an Ag/AgCl reference electrode. In order to provide nanostructure, soft lithography using a polymeric blend was employed to create a flexible nanopillar backbone film. Polyaniline-sensing materials were deposited on a patterned-nanopillar array by electrochemical deposition. The pH sensors produced exhibited a near-Nernstian response (∼60.3mV/pH), which was maintained in a bent state. In addition, pH sensors showed other excellent sensor performances in terms of response time, reversibility, repeatability, selectivity, and stability. Copyright © 2016 Elsevier Inc. All rights reserved.
Organic bistable memory devices based on MoO3 nanoparticle embedded Alq3 structures
NASA Astrophysics Data System (ADS)
Abhijith, T.; Kumar, T. V. Arun; Reddy, V. S.
2017-03-01
Organic bistable memory devices were fabricated by embedding a thin layer of molybdenum trioxide (MoO3) between two tris-(8-hydroxyquinoline)aluminum (Alq3) layers. The device exhibited excellent switching characteristics with an ON/OFF current ratio of 1.15 × 103 at a read voltage of 1 V. The device showed repeatable write-erase capability and good stability in both the conductance states. These conductance states are non-volatile in nature and can be obtained by applying appropriate voltage pulses. The effect of MoO3 layer thickness and its location in the Alq3 matrix on characteristics of the memory device was investigated. The field emission scanning electron microscopy (FE-SEM) images of the MoO3 layer revealed the presence of isolated nanoparticles. Based on the experimental results, a mechanism has been proposed for explaining the conductance switching of fabricated devices.
Calibration of erythemally weighted broadband instruments: A comparison between PMOD/WRC and MSL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swift, Neil; Nield, Kathryn; Hamlin, John
A Yankee Environmental Systems (YES) UVB-1 ultraviolet pyranometer, designed to measure erythemally weighted total solar irradiance, was calibrated by the Measurement Standards Laboratory (MSL) in Lower Hutt, New Zealand during August 2010. The calibration was then repeated during July and August 2011 by the Physikalisch-Meteorologisches Obervatorium Davos, World Radiation Center (PMOD/WRC) located in Davos, Switzerland. Calibration results show that measurements of the relative spectral and angular response functions at the two institutes are in excellent agreement, thus providing a good degree of confidence in these measurement facilities. However, measurements to convert the relative spectral response into an absolute calibration disagreemore » significantly depending on whether an FEL lamp or solar spectra are used to perform this scaling. This is the first serious comparison of these scaling methods to formally explore the potential systematic errors which could explain the discrepancy.« less
Reusable self-healing hydrogels realized via in situ polymerization.
Vivek, Balachandran; Prasad, Edamana
2015-04-09
In this work, a self-healing hydrogel has been prepared using in situ polymerization of acrylic acid and acrylamide in the presence of glycogen. The hydrogel was characterized using NMR, SEM, FT-IR, rheology, and dynamic light scattering (DLS) studies. The developed hydrogel exhibits self-healing properties at neutral pH, high swelling ability, high elasticity, and excellent mechanical strength. The hydrogel exhibits modulus values (G', G″) as high as 10(6) Pa and shows an exceptionally high degree of swelling ratio (∼3.5 × 10(3)). Further, the polymer based hydrogel adsorbs toxic metal ions (Cd(2+), Pb(2+), and Hg(2+)) and organic dyes (methylene blue and methyl orange) from contaminated water with remarkable efficiency (90-98%). The mechanistic analysis indicated the presence of pseudo-second-order reaction kinetics. The reusability of the hydrogel has been demonstrated by repeating the adsorption-desorption process over five cycles with identical results in the adsorption efficiency.
Ca2+-stabilized adhesin helps an Antarctic bacterium reach out and bind ice.
Vance, Tyler D R; Olijve, Luuk L C; Campbell, Robert L; Voets, Ilja K; Davies, Peter L; Guo, Shuaiqi
2014-07-04
The large size of a 1.5-MDa ice-binding adhesin [MpAFP (Marinomonas primoryensis antifreeze protein)] from an Antarctic Gram-negative bacterium, M. primoryensis, is mainly due to its highly repetitive RII (Region II). MpAFP_RII contains roughly 120 tandem copies of an identical 104-residue repeat. We have previously determined that a single RII repeat folds as a Ca2+-dependent immunoglobulin-like domain. Here, we solved the crystal structure of RII tetra-tandemer (four tandem RII repeats) to a resolution of 1.8 Å. The RII tetra-tandemer reveals an extended (~190-Å × ~25-Å), rod-like structure with four RII-repeats aligned in series with each other. The inter-repeat regions of the RII tetra-tandemer are strengthened by Ca2+ bound to acidic residues. SAXS (small-angle X-ray scattering) profiles indicate the RII tetra-tandemer is significantly rigidified upon Ca2+ binding, and that the protein's solution structure is in excellent agreement with its crystal structure. We hypothesize that >600 Ca2+ help rigidify the chain of ~120 104-residue repeats to form a ~0.6 μm rod-like structure in order to project the ice-binding domain of MpAFP away from the bacterial cell surface. The proposed extender role of RII can help the strictly aerobic, motile bacterium bind ice in the upper reaches of the Antarctic lake where oxygen and nutrients are most abundant. Ca2+-induced rigidity of tandem Ig-like repeats in large adhesins might be a general mechanism used by bacteria to bind to their substrates and help colonize specific niches.
Momosawa, Akira; Kurita, Masakazu; Ozaki, Mine; Miyamoto, Shinpei; Kobayashi, Yo; Ban, Izumi; Harii, Kiyonori
2008-01-01
Periorbital skin hyperpigmentation, so-called dark circles, is of major concern for many people. However, only a few reports refer to the morbidity and treatment, and as far as the authors know, there are no reports of the condition in Asians. A total of 18 Japanese patients underwent combined therapy using Q-switched ruby laser to eliminate dermal pigmentation following topical bleaching treatment with tretinoin aqueous gel and hydroquinone ointment performed initially (6 weeks) to reduce epidermal melanin. Both steps were repeated two to four times until physical clearance of the pigmentation was confirmed and patient satisfaction was achieved. Skin biopsy was performed at baseline in each patient and at the end of treatment in three patients, all with informed consent. Clinical and histologic appearances of periorbital hyperpigmentation were evaluated and rated as excellent, good, fair, poor, or default. Seven of 18 patients (38.9 percent) showed excellent clearing after treatment and eight (44.4 percent) were rated good. Only one (5.6 percent) was rated fair and none was rated poor. Postinflammatory hyperpigmentation was observed in only two patients (11.1 percent). Histologic examination showed obvious epidermal hyperpigmentation in 10 specimens. Dermal pigmentation was observed in all specimens but was not considered to be melanocytosis. Remarkable reduction of dermal pigmentation was observed in the biopsy specimens of three patients after treatment. The new treatment protocol combining Q-switched ruby laser and topical bleaching treatment using tretinoin and hydroquinone is considered effective for improvement of periorbital skin hyperpigmentation, with a low incidence of postinflammatory hyperpigmentation.
Dasary, Samuel S.R.; Zones, Yolanda K.; Barnes, Sandra L.; Ray, P. C.; Singh, Anant K.
2015-01-01
Alizarin functionalized on plasmonic gold nanoparticle displays strong surface enhanced Raman scattering from the various Raman modes of Alizarin, which can be exploited in multiple ways for heavy metal sensing purposes. The present article reports a surface enhanced Raman spectroscopy (SERS) probe for trace level Cadmium in water samples. Alizarin, a highly Raman active dye was functionalized on plasmonic gold surface as a Raman reporter, and then 3-mercaptopropionic acid, 2,6-Pyridinedicarboxylic acid at pH 8.5 was immobilized on the surface of the nanoparticle for the selective coordination of the Cd (II). Upon addition of Cadmium, gold nanoparticle provide an excellent hotspot for Alizarin dye and Raman signal enhancement. This plasmonic SERS assay provided an excellent sensitivity for Cadmium detection from the drinking water samples. We achieved as low as 10 ppt sensitivity from various drinking water sources against other Alkali and heavy metal ions. The developed SERS probe is quite simple and rapid with excellent repeatability and has great potential for prototype scale up for field application. PMID:26770012
Mansberger, Steven L; Sheppler, Christina R; McClure, Tina M; Vanalstine, Cory L; Swanson, Ingrid L; Stoumbos, Zoey; Lambert, William E
2013-09-01
To report the psychometrics of the Glaucoma Treatment Compliance Assessment Tool (GTCAT), a new questionnaire designed to assess adherence with glaucoma therapy. We developed the questionnaire according to the constructs of the Health Belief Model. We evaluated the questionnaire using data from a cross-sectional study with focus groups (n = 20) and a prospective observational case series (n=58). Principal components analysis provided assessment of construct validity. We repeated the questionnaire after 3 months for test-retest reliability. We evaluated predictive validity using an electronic dosing monitor as an objective measure of adherence. Focus group participants provided 931 statements related to adherence, of which 88.7% (826/931) could be categorized into the constructs of the Health Belief Model. Perceived barriers accounted for 31% (288/931) of statements, cues-to-action 14% (131/931), susceptibility 12% (116/931), benefits 12% (115/931), severity 10% (91/931), and self-efficacy 9% (85/931). The principal components analysis explained 77% of the variance with five components representing Health Belief Model constructs. Reliability analyses showed acceptable Cronbach's alphas (>.70) for four of the seven components (severity, susceptibility, barriers [eye drop administration], and barriers [discomfort]). Predictive validity was high, with several Health Belief Model questions significantly associated (P <.05) with adherence and a correlation coefficient (R (2)) of .40. Test-retest reliability was 90%. The GTCAT shows excellent repeatability, content, construct, and predictive validity for glaucoma adherence. A multisite trial is needed to determine whether the results can be generalized and whether the questionnaire accurately measures the effect of interventions to increase adherence.
Li, Hongkai; Yuan, Zhongshang; Ji, Jiadong; Xu, Jing; Zhang, Tao; Zhang, Xiaoshuai; Xue, Fuzhong
2016-03-09
We propose a novel Markov Blanket-based repeated-fishing strategy (MBRFS) in attempt to increase the power of existing Markov Blanket method (DASSO-MB) and maintain its advantages in omic data analysis. Both simulation and real data analysis were conducted to assess its performances by comparing with other methods including χ(2) test with Bonferroni and B-H adjustment, least absolute shrinkage and selection operator (LASSO) and DASSO-MB. A serious of simulation studies showed that the true discovery rate (TDR) of proposed MBRFS was always close to zero under null hypothesis (odds ratio = 1 for each SNPs) with excellent stability in all three scenarios of independent phenotype-related SNPs without linkage disequilibrium (LD) around them, correlated phenotype-related SNPs without LD around them, and phenotype-related SNPs with strong LD around them. As expected, under different odds ratio and minor allel frequency (MAFs), MBRFS always had the best performances in capturing the true phenotype-related biomarkers with higher matthews correlation coefficience (MCC) for all three scenarios above. More importantly, since proposed MBRFS using the repeated fishing strategy, it still captures more phenotype-related SNPs with minor effects when non-significant phenotype-related SNPs emerged under χ(2) test after Bonferroni multiple correction. The various real omics data analysis, including GWAS data, DNA methylation data, gene expression data and metabolites data, indicated that the proposed MBRFS always detected relatively reasonable biomarkers. Our proposed MBRFS can exactly capture the true phenotype-related biomarkers with the reduction of false negative rate when the phenotype-related biomarkers are independent or correlated, as well as the circumstance that phenotype-related biomarkers are associated with non-phenotype-related ones.
Management of Lignite Fly Ash for Improving Soil Fertility and Crop Productivity
NASA Astrophysics Data System (ADS)
Ram, Lal C.; Srivastava, Nishant K.; Jha, Sangeet K.; Sinha, Awadhesh K.; Masto, Reginald E.; Selvi, Vetrivel A.
2007-09-01
Lignite fly ash (LFA), being alkaline and endowed with excellent pozzolanic properties, a silt loam texture, and plant nutrients, has the potential to improve soil quality and productivity. Long-term field trials with groundnut, maize, and sun hemp were carried out to study the effect of LFA on growth and yield. Before crop I was sown, LFA was applied at various doses with and without press mud (an organic waste from the sugar industry, used as an amendment and source of nutrients). LFA with and without press mud was also applied before crops III and V were cultivated. Chemical fertilizer, along with gypsum, humic acid, and biofertilizer, was applied in all treatments, including the control. With one-time and repeat applications of LFA (with and without press mud), yield increased significantly (7.0-89.0%) in relation to the control crop. The press mud enhanced the yield (3.0-15.0%) with different LFA applications. The highest yield LFA dose was 200 t/ha for one-time and repeat applications, the maximum yield being with crop III (combination treatment). One-time and repeat application of LFA (alone and in combination with press mud) improved soil quality and the nutrient content of the produce. The highest dose of LFA (200 t/ha) with and without press mud showed the best residual effects (eco-friendly increases in the yield of succeeding crops). Some increase in trace- and heavy-metal contents and in the level of γ-emitters in soil and crop produce, but well within permissible limits, was observed. Thus, LFA can be used on a large scale to boost soil fertility and productivity with no adverse effects on the soil or crops, which may solve the problem of bulk disposal of fly ash in an eco-friendly manner.
Gu, Dongfeng; Zhao, Qi; Chen, Jing; Chen, Ji-Chun; Huang, Jianfeng; Bazzano, Lydia A; Lu, Fanghong; Mu, Jianjun; Li, Jianxin; Cao, Jie; Mills, Katherine; Chen, Chung-Shiuan; Rice, Treva; Hamm, L Lee; He, Jiang
2013-09-01
Blood pressure responses to dietary sodium and potassium interventions vary among individuals. We studied the long-term reproducibility of blood pressure responses to dietary sodium and potassium intake. We repeated the dietary sodium and potassium interventions among 487 Chinese adults 4.5 years after the original dietary intervention. The identical dietary intervention protocol, which included a 7-day low-sodium feeding (51.3 mmol/d), a 7-day high-sodium feeding (307.8 mmol/d), and a 7-day high-sodium feeding with oral potassium supplementation (60.0 mmol/d), was applied in both the initial and repeated studies. Three blood pressure measurements were obtained during each of the 3 days of baseline observation and on days 5, 6, and 7 of each intervention period. The results from the 24-hour urinary excretion of sodium and potassium showed excellent compliance with the study diet. Blood pressure responses to dietary intervention in the original and repeated studies were highly correlated. For example, the correlation coefficients (95% confidence interval) for systolic blood pressure levels were 0.77 (0.73-0.80) at baseline, 0.79 (0.75-0.82) during low sodium, 0.80 (0.77-0.83) during high sodium, and 0.82 (0.79-0.85) during high sodium and potassium supplementation interventions (all P<0.0001). The correlation coefficients for systolic blood pressure changes were 0.37 (0.29-0.44) from baseline to low sodium, 0.37 (0.29-0.44) from low to high sodium, and 0.28 (0.20-0.36) from high sodium to high sodium plus potassium supplementation (all P<0.0001). These data indicate that blood pressure responses to dietary sodium and potassium interventions have long-term reproducibility and stable characteristics in the general population.
Reproducibility of regional DEXA examinations of abdominal fat and lean tissue.
Tallroth, Kaj; Kettunen, Jyrki A; Kujala, Urho M
2013-01-01
The aim of this study was to develop and test the validity of a new repeatable method to delimit abdominal areas for follow-up of fat mass (FM) and lean tissue mass (LM) in DEXA examinations. 37 male volunteers underwent two DEXA examinations. Total body FM and LM measurements and corresponding abdominal measurements in a carefully defined region were calculated from the first scan. After repositioning of the subjects and a second scan, the delimited region was copied and the abdominal tissues re-calculated. The mean LM of the abdominal area was 2.804 kg (SD 0.556), and the mean FM was 1.026 kg (SD 0.537). The intra-class correlation coefficient for the repeated abdominal LM, FM, and LM/FM ratio measurements was 0.99. The mean difference (bias) for the repeated abdominal LM measurements was -13 g (95% confidence interval (CI) -193.0 to 166.8), and for the repeated abdominal FM measurements it was -35 g (95% CI -178.9 to 108.5). The results indicate that regional DEXA is a sensitive method with excellent reproducibility in the measurements of the abdominal fat and lean tissues. The method may serve as a useful tool for evaluation and follow-up of various dietary and training programmes.
Reproducibility of Regional DEXA Examinations of Abdominal Fat and Lean Tissue
Tallroth, Kaj; Kettunen, Jyrki A.; Kujala, Urho M.
2013-01-01
Objective The aim of this study was to develop and test the validity of a new repeatable method to delimit abdominal areas for follow-up of fat mass (FM) and lean tissue mass (LM) in DEXA examinations. Methods 37 male volunteers underwent two DEXA examinations. Total body FM and LM measurements and corresponding abdominal measurements in a carefully defined region were calculated from the first scan. After repositioning of the subjects and a second scan, the delimited region was copied and the abdominal tissues re-calculated. Results The mean LM of the abdominal area was 2.804 kg (SD 0.556), and the mean FM was 1.026 kg (SD 0.537). The intra-class correlation coefficient for the repeated abdominal LM, FM, and LM/FM ratio measurements was 0.99. The mean difference (bias) for the repeated abdominal LM measurements was −13 g (95% confidence interval (CI) −193.0 to 166.8), and for the repeated abdominal FM measurements it was −35 g (95% CI −178.9 to 108.5). Conclusions The results indicate that regional DEXA is a sensitive method with excellent reproducibility in the measurements of the abdominal fat and lean tissues. The method may serve as a useful tool for evaluation and follow-up of various dietary and training programmes. PMID:23615566
NASA Technical Reports Server (NTRS)
Arnold, Steven M. (Technical Monitor); Bansal, Yogesh; Pindera, Marek-Jerzy
2004-01-01
The High-Fidelity Generalized Method of Cells is a new micromechanics model for unidirectionally reinforced periodic multiphase materials that was developed to overcome the original model's shortcomings. The high-fidelity version predicts the local stress and strain fields with dramatically greater accuracy relative to the original model through the use of a better displacement field representation. Herein, we test the high-fidelity model's predictive capability in estimating the elastic moduli of periodic composites characterized by repeating unit cells obtained by rotation of an infinite square fiber array through an angle about the fiber axis. Such repeating unit cells may contain a few or many fibers, depending on the rotation angle. In order to analyze such multi-inclusion repeating unit cells efficiently, the high-fidelity micromechanics model's framework is reformulated using the local/global stiffness matrix approach. The excellent agreement with the corresponding results obtained from the standard transformation equations confirms the new model's predictive capability for periodic composites characterized by multi-inclusion repeating unit cells lacking planes of material symmetry. Comparison of the effective moduli and local stress fields with the corresponding results obtained from the original Generalized Method of Cells dramatically highlights the original model's shortcomings for certain classes of unidirectional composites.
1998-06-05
judgment, intuition, and empathy . Integration is most clearly identified in CTC lessons learned, particularly in its relation to the synchronization of...and empathy can be inferred from the results of some battles, but is not discussed in CALL materials. Some observations can be made about initiative...operations. Repeated practice can increase both knowledge and experi- ence and increase intuition and empathy as well. A seasoned combat commander
NASA Astrophysics Data System (ADS)
Wang, Fan; Zhang, Lijuan; Wang, Yeying; Liu, Xijian; Rohani, Sohrab; Lu, Jie
2017-10-01
The graphene oxide (GO) functionalized by Fe3O4@SiO2@CS-TETA nanoparticles, Fe3O4@SiO2@CS-TETA-GO, was firstly fabricated in a mild way as a novel adsorbent for the removal of Cu(II) ions and methylene blue (MB) from aqueous solutions. The magnetic composites showed a good dispersity in water and can be conveniently collected for reuse through magnetic separation due to its excellent magnetism. When the Fe3O4@SiO2@CS- TETA-GO was used as an absorbent for the absorption of MB and Cu(II), the adsorption kinetics and isotherms data well fitted the pseudo-second-order model and the Langmuir model, respectively. Under the optimized pH and initial concentration, the maximum adsorption capacity was about 529.1 mg g-1 for MB in 20 min and 324.7 mg g-1 for Cu(II) in 16 min, respectively, exhibiting a better adsorption performance than other GO-based adsorbents reported recently. More importantly, the synthesized adsorbent could be effectively regenerated and repeatedly utilized without significant capacity loss after six times cycles. All the results demonstrated that Fe3O4@SiO2@CS-TETA-GO could be used as an excellent adsorbent for the adsorption of Cu(II) and MB in many fields.
Zhao, Rongtao; Kong, Wen; Sun, Mingxuan; Yang, Yi; Liu, Wanying; Lv, Min; Song, Shiping; Wang, Lihua; Song, Hongbin; Hao, Rongzhang
2018-05-30
Various silver nanoparticle (AgNP)-decorated graphene oxide (GO) nanocomposites (GO-Ag) have received increasing attention owing to their antimicrobial activity and biocompatibility; however, their aggregation in physiological solutions and the generally complex synthesis methods warrant improvement. This study aimed to synthesize a polyethyleneimine (PEI)-modified and AgNP-decorated GO nanocomposite (GO-PEI-Ag) through a facile approach through microwave irradiation without any extra reductants and surfactants; its antimicrobial activity was investigated on Gram-negative/-positive bacteria (including drug-resistant bacteria) and fungi. Compared with GO-Ag, GO-PEI-Ag acquired excellent stability in physiological solutions and electropositivity, showing substantially higher antimicrobial efficacy. Moreover, GO-PEI-Ag exhibited particularly excellent long-term effects, presenting no obvious decline in antimicrobial activity after 1 week storage in physiological saline and repeated use for three times and the lasting inhibition of bacterial growth in nutrient-rich culture medium. In contrast, GO-Ag exhibited a >60% decline in antimicrobial activity after storage. Importantly, GO-PEI-Ag effectively eliminated adhered bacteria, thereby preventing biofilm formation. The primary antimicrobial mechanisms of GO-PEI-Ag were evidenced as physical damage to the pathogen structure, causing cytoplasmic leakage. Hence, stable GO-PEI-Ag with robust, long-term antimicrobial activity holds promise in combating public-health threats posed by drug-resistant bacteria and biofilms.
Paseiro-Cerrato, R; de Quirós, A Rodríguez-Bernaldo; Sendón, Raquel; Bustos, Juana; Ruíz, E; Cruz, J M; Paseiro-Losada, P
2011-10-07
This paper describes the development of a multi-analyte method for the determination of polyfunctional amines commonly used as monomers in the manufacture of food contact materials. Amines were analyzed by high-performance-liquid chromatography with diode-array detection (HPLC-DAD) after derivatization with dansyl chloride. The chromatographic analysis and the derivatization conditions were optimized. The proposed method was validated in terms of linearity, limits of detection and repeatabilities. The method showed an excellent sensitivity (LOD≤0.05 μg/mL) and appropriate repeatabilites (RSD (n=7)≤5%)). LC-MS/MS was used as a confirmatory technique. The stability of the amines in five food simulants (distilled water, 3% acetic acid, 10% ethanol, 50% ethanol and olive oil) under the most common testing conditions (10 days at 40 °C) was also studied. Results showed that amines had an acceptable stability in aqueous simulants but in the olive oil a loss of 100% was observed for all analytes. Copyright © 2011. Published by Elsevier B.V.
Siddiq, Abdur R; Kennedy, Andrew R
2015-02-01
Porous PEEK structures with approximately 85% open porosity have been made using PEEK-OPTIMA® powder and a particulate leaching technique using porous, near-spherical, sodium chloride beads. A novel manufacturing approach is presented and compared with a traditional dry mixing method. Irrespective of the method used, the use of near-spherical beads with a fairly narrow size range results in uniform pore structures. However the integration, by tapping, of fine PEEK into a pre-existing network salt beads, followed by compaction and "sintering", produces porous structures with excellent repeatability and homogeneity of density; more uniform pore and strut sizes; an improved and predictable level of connectivity via the formation of "windows" between the cells; faster salt removal rates and lower levels of residual salt. Although tapped samples show a compressive yield stress >1 MPa and stiffness >30 MPa for samples with 84% porosity, the presence of windows in the cell walls means that tapped structures show lower strengths and lower stiffnesses than equivalent structures made by mixing. Copyright © 2014 Elsevier B.V. All rights reserved.
Junction-Free Electrospun Ag Fiber Electrodes for Flexible Organic Light-Emitting Diodes.
Choi, Junhee; Shim, Yong Sub; Park, Cheol Hwee; Hwang, Ha; Kwack, Jin Ho; Lee, Dong Jun; Park, Young Wook; Ju, Byeong-Kwon
2018-02-01
Fabrication of junction-free Ag fiber electrodes for flexible organic light-emitting diodes (OLEDs) is demonstrated. The junction-free Ag fiber electrodes are fabricated by electrospun polymer fibers used as an etch mask and wet etching of Ag thin film. This process facilitates surface roughness control, which is important in transparent electrodes based on metal wires to prevent electrical instability of the OLEDs. The transmittance and resistance of Ag fiber electrodes can be independently adjusted by controlling spinning time and Ag deposition thickness. The Ag fiber electrode shows a transmittance of 91.8% (at 550 nm) at a sheet resistance of 22.3 Ω □ -1 , leading to the highest OLED efficiency. In addition, Ag fiber electrodes exhibit excellent mechanical durability, as shown by measuring the change in resistance under repeatable mechanical bending and various bending radii. The OLEDs with Ag fiber electrodes on a flexible substrate are successfully fabricated, and the OLEDs show an enhancement of EQE (≈19%) compared to commercial indium tin oxide electrodes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Dubourg, Georges; Segkos, Apostolos; Katona, Jaroslav; Radović, Marko; Savić, Slavica; Crnojević-Bengin, Vesna
2017-01-01
This paper describes the fabrication and the characterization of an original example of a miniaturized resistive-type humidity sensor, printed on flexible substrate in a large-scale manner. The fabrication process involves laser ablation for the design of interdigitated electrodes on PET (Poly-Ethylene Terephthalate) substrate and a screen-printing process for the deposition of the sensitive material, which is based on TiO2 nanoparticles. The laser ablation process was carefully optimized to obtain micro-scale and well-resolved electrodes on PET substrate. A functional paste based on cellulose was prepared in order to allow the precise screen-printing of the TiO2 nanoparticles as sensing material on the top of the electrodes. The current against voltage (I–V) characteristic of the sensor showed good linearity and potential for low-power operation. The results of a humidity-sensing investigation and mechanical testing showed that the fabricated miniaturized sensors have excellent mechanical stability, sensing characteristics, good repeatability, and relatively fast response/recovery times operating at room temperature. PMID:28800063
Identification of positive selection in disease response genes within members of the Poaceae.
Rech, Gabriel E; Vargas, Walter A; Sukno, Serenella A; Thon, Michael R
2012-12-01
Millions of years of coevolution between plants and pathogens can leave footprints on their genomes and genes involved on this interaction are expected to show patterns of positive selection in which novel, beneficial alleles are rapidly fixed within the population. Using information about upregulated genes in maize during Colletotrichum graminicola infection and resources available in the Phytozome database, we looked for evidence of positive selection in the Poaceae lineage, acting on protein coding sequences related with plant defense. We found six genes with evidence of positive selection and another eight with sites showing episodic selection. Some of them have already been described as evolving under positive selection, but others are reported here for the first time including genes encoding isocitrate lyase, dehydrogenases, a multidrug transporter, a protein containing a putative leucine-rich repeat and other proteins with unknown functions. Mapping positively selected residues onto the predicted 3-D structure of proteins showed that most of them are located on the surface, where proteins are in contact with other molecules. We present here a set of Poaceae genes that are likely to be involved in plant defense mechanisms and have evidence of positive selection. These genes are excellent candidates for future functional validation.
Yang, Zhiman; Xu, Xiaohui; Dai, Meng; Wang, Lin; Shi, Xiaoshuang; Guo, Rongbo
2018-04-22
The batch and fed-batch tests were performed to evaluate the efficiency of bioaugmentation in combination with biostimulation for remediation of paddy soil contaminated with 2,4-dichlorophenoxyacetic acid (2,4-D). 2,4-D degrading enrichments were used for bioaugmentation, and effluents prepared through biological hydrogen production process were used as substrate for biostimulation. The batch tests indicated that 2,4-D degradation depended on the enrichment/substrate ratio (E/S), where E/S of 0.03 showed an excellent performance. The fed-batch tests showed that biostimulation only led to an improvement in 2,4-D degradation, while the pattern of repeated augmentation of enrichments (FRA) together with biostimulation obviously improved degradation of 2,4-D, 2-chlorophenol (2-CP) and phenol. DNA-sequencing approach showed that the FRA pattern altered the bacterial community composition, and high removal of 2,4-D, 2-CP and phenol may be attributed to the acclimation and persistence of Thauera. The findings demonstrated the importance of the FRA pattern on remediation of paddy soil contaminated with 2,4-D. Copyright © 2018 Elsevier B.V. All rights reserved.
Hydrogel Walkers with Electro-Driven Motility for Cargo Transport.
Yang, Chao; Wang, Wei; Yao, Chen; Xie, Rui; Ju, Xiao-Jie; Liu, Zhuang; Chu, Liang-Yin
2015-08-28
In this study, soft hydrogel walkers with electro-driven motility for cargo transport have been developed via a facile mould-assisted strategy. The hydrogel walkers consisting of polyanionic poly(2-acrylamido-2-methylpropanesulfonic acid-co-acrylamide) exhibit an arc looper-like shape with two "legs" for walking. The hydrogel walkers can reversibly bend and stretch via repeated "on/off" electro-triggers in electrolyte solution. Based on such bending/stretching behaviors, the hydrogel walkers can move their two "legs" to achieve one-directional walking motion on a rough surface via repeated "on/off" electro-triggering cycles. Moreover, the hydrogel walkers loaded with very heavy cargo also exhibit excellent walking motion for cargo transport. Such hydrogel systems create new opportunities for developing electro-controlled soft systems with simple design/fabrication strategies in the soft robotic field for remote manipulation and transportation.
Validation of a portable nitric oxide analyzer for screening in primary ciliary dyskinesias.
Harris, Amanda; Bhullar, Esther; Gove, Kerry; Joslin, Rhiannon; Pelling, Jennifer; Evans, Hazel J; Walker, Woolf T; Lucas, Jane S
2014-02-10
Nasal nitric oxide (nNO) levels are very low in primary ciliary dyskinesia (PCD) and it is used as a screening test. We assessed the reliability and usability of a hand-held analyser in comparison to a stationary nitric oxide (NO) analyser in 50 participants (15 healthy, 13 PCD, 22 other respiratory diseases; age 6-79 years). Nasal NO was measured using a stationary NO analyser during a breath-holding maneuver, and using a hand-held analyser during tidal breathing, sampling at 2 ml/sec or 5 ml/sec. The three methods were compared for their specificity and sensitivity as a screen for PCD, their success rate in different age groups, within subject repeatability and acceptability. Correlation between methods was assessed. Valid nNO measurements were obtained in 94% of participants using the stationary analyser, 96% using the hand-held analyser at 5 ml/sec and 76% at 2 ml/sec. The hand-held device at 5 ml/sec had excellent sensitivity and specificity as a screening test for PCD during tidal breathing (cut-off of 30 nL/min,100% sensitivity, >95% specificity). The cut-off using the stationary analyser during breath-hold was 38 nL/min (100% sensitivity, 95% specificity). The stationary and hand-held analyser (5 ml/sec) showed reasonable within-subject repeatability(% coefficient of variation = 15). The hand-held NO analyser provides a promising screening tool for PCD.
2014-01-01
Background Mechanical loads induced through muscle contraction, vibration, or compressive forces are thought to modulate tissue plasticity. With the emergence of regenerative medicine, there is a need to understand the optimal mechanical environment (vibration, load, or muscle force) that promotes cellular health. To our knowledge no mechanical system has been proposed to deliver these isolated mechanical stimuli in human tissue. We present the design, performance, and utilization of a new technology that may be used to study localized mechanical stimuli on human tissues. A servo-controlled vibration and limb loading system were developed and integrated into a single instrument to deliver vibration, compression, or muscle contractile loads to a single limb (tibia) in humans. The accuracy, repeatability, transmissibility, and safety of the mechanical delivery system were evaluated on eight individuals with spinal cord injury (SCI). Findings The limb loading system was linear, repeatable, and accurate to less than 5, 1, and 1 percent of full scale, respectively, and transmissibility was excellent. The between session tests on individuals with spinal cord injury (SCI) showed high intra-class correlations (>0.9). Conclusions All tests supported that therapeutic loads can be delivered to a lower limb (tibia) in a safe, accurate, and measureable manner. Future collaborations between engineers and cellular physiologists will be important as research programs strive to determine the optimal mechanical environment for developing cells and tissues in humans. PMID:24894666
NASA Astrophysics Data System (ADS)
Sitnikov, Dmitri G.; Monnin, Cian S.; Vuckovic, Dajana
2016-12-01
The comparison of extraction methods for global metabolomics is usually executed in biofluids only and focuses on metabolite coverage and method repeatability. This limits our detailed understanding of extraction parameters such as recovery and matrix effects and prevents side-by-side comparison of different sample preparation strategies. To address this gap in knowledge, seven solvent-based and solid-phase extraction methods were systematically evaluated using standard analytes spiked into both buffer and human plasma. We compared recovery, coverage, repeatability, matrix effects, selectivity and orthogonality of all methods tested for non-lipid metabolome in combination with reversed-phased and mixed-mode liquid chromatography mass spectrometry analysis (LC-MS). Our results confirmed wide selectivity and excellent precision of solvent precipitations, but revealed their high susceptibility to matrix effects. The use of all seven methods showed high overlap and redundancy which resulted in metabolite coverage increases of 34-80% depending on LC-MS method employed as compared to the best single extraction protocol (methanol/ethanol precipitation) despite 7x increase in MS analysis time and sample consumption. The most orthogonal methods to methanol-based precipitation were ion-exchange solid-phase extraction and liquid-liquid extraction using methyl-tertbutyl ether. Our results help facilitate rational design and selection of sample preparation methods and internal standards for global metabolomics.
Wang, Yimin; Fawzi, Amani A.; Varma, Rohit; Sadun, Alfredo A.; Zhang, Xinbo; Tan, Ou; Izatt, Joseph A.
2011-01-01
Purpose. To investigate blood flow changes in retinal and optic nerve diseases with Doppler Fourier domain optical coherence tomography (OCT). Methods. Sixty-two participants were divided into five groups: normal, glaucoma, nonarteritic ischemic optic neuropathy (NAION), treated proliferative diabetic retinopathy (PDR), and branch retinal vein occlusion (BRVO). Doppler OCT was used to scan concentric circles of 3.4- and 3.75-mm diameters around the optic nerve head. Flow in retinal veins was calculated from the OCT velocity profiles. Arterial and venous diameters were measured from OCT Doppler and reflectance images. Results. Total retinal blood flow in normal subjects averaged 47.6 μL/min. The coefficient of variation of repeated measurements was 11% in normal eyes and 14% in diseased eyes. Eyes with glaucoma, NAION, treated PDR, and BRVO had significantly decreased retinal blood flow compared with normal eyes (P < 0.001). In glaucoma patients, the decrease in blood flow was highly correlated with the severity of visual field loss (P = 0.003). In NAION and BRVO patients, the hemisphere with more severe disease also had lower blood flow. Conclusions. Doppler OCT retinal blood flow measurements showed good repeatability and excellent correlation with visual field and clinical presentations. This approach could enhance our understanding of retinal and optic nerve diseases and facilitate the development of new therapies. PMID:21051715
Sitnikov, Dmitri G.; Monnin, Cian S.; Vuckovic, Dajana
2016-01-01
The comparison of extraction methods for global metabolomics is usually executed in biofluids only and focuses on metabolite coverage and method repeatability. This limits our detailed understanding of extraction parameters such as recovery and matrix effects and prevents side-by-side comparison of different sample preparation strategies. To address this gap in knowledge, seven solvent-based and solid-phase extraction methods were systematically evaluated using standard analytes spiked into both buffer and human plasma. We compared recovery, coverage, repeatability, matrix effects, selectivity and orthogonality of all methods tested for non-lipid metabolome in combination with reversed-phased and mixed-mode liquid chromatography mass spectrometry analysis (LC-MS). Our results confirmed wide selectivity and excellent precision of solvent precipitations, but revealed their high susceptibility to matrix effects. The use of all seven methods showed high overlap and redundancy which resulted in metabolite coverage increases of 34–80% depending on LC-MS method employed as compared to the best single extraction protocol (methanol/ethanol precipitation) despite 7x increase in MS analysis time and sample consumption. The most orthogonal methods to methanol-based precipitation were ion-exchange solid-phase extraction and liquid-liquid extraction using methyl-tertbutyl ether. Our results help facilitate rational design and selection of sample preparation methods and internal standards for global metabolomics. PMID:28000704
Wang, Kai; Meng, Qinghai; Zhang, Yajie; Wei, Zhixiang; Miao, Menghe
2013-03-13
Fine count two-ply yarn supercapacitors are constructed from carbon nanotube yarns and polyaniline nanowires. The thread-like supercapacitor possess excellent electrochemical capacity and are very strong and flexible. When being woven or knitted into wearable electronic devices, alone or in combination with conventional textile yarns, the two-ply yarn supercapacitors can be flexed and stretched repeatedly without significant loss of capacitance. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Population mixture model for nonlinear telomere dynamics
NASA Astrophysics Data System (ADS)
Itzkovitz, Shalev; Shlush, Liran I.; Gluck, Dan; Skorecki, Karl
2008-12-01
Telomeres are DNA repeats protecting chromosomal ends which shorten with each cell division, eventually leading to cessation of cell growth. We present a population mixture model that predicts an exponential decrease in telomere length with time. We analytically solve the dynamics of the telomere length distribution. The model provides an excellent fit to available telomere data and accounts for the previously unexplained observation of telomere elongation following stress and bone marrow transplantation, thereby providing insight into the nature of the telomere clock.
McClellan, Taylor; Allen, Brian C; Kappus, Matthew; Bhatti, Lubna; Dafalla, Randa A; Snyder, Laurie D; Bashir, Mustafa R
To determine interreader and intrareader repeatability and correlations among measurements of computerized tomography-based anthropomorphic measurements in patients with pulmonary fibrosis undergoing lung transplantation. This was an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study of 23 randomly selected subjects (19 male and 4 female; median age = 69 years; range: 66-77 years) with idiopathic pulmonary fibrosis undergoing pulmonary transplantation, who had also undergone preoperative thoracoabdominal computerized tomography. Five readers of varying imaging experience independently performed the following cross-sectional area measurements at the inferior endplate of the L3 vertebral body: right and left psoas muscles, right and left paraspinal muscles, total abdominal musculature, and visceral and subcutaneous fat. The following measurements were obtained at the inferior endplate of T6: right and left paraspinal muscles with and without including the trapezius muscles and subcutaneous fat. Three readers repeated all measurements to assess intrareader repeatability. Intrareader repeatability was nearly perfect (interclass correlation coefficients = 0.99, P < 0.001). Interreader agreement was excellent across all 5 readers (interclass correlation coefficients: 0.71-0.99, P < 0.001). Coefficients of variance between measures ranged from 3.2%-6.8% for abdominal measurements, but were higher for thoracic measurements, up to 23.9%. Correlation between total paraspinal and total psoas muscle area was strong (r 2 = 0.67, P < 0.001). Thoracic and abdominal musculature had a weaker correlation (r 2 = 0.35-0.38, P < 0.001). Measures of thoracic and abdominal muscle and fat area are highly repeatable in patients with pulmonary fibrosis undergoing lung transplantation. Measures of muscle area are strongly correlated among abdominal locations, but inversely correlated between abdominal and thoracic locations. Copyright © 2017 Elsevier Inc. All rights reserved.
Rockall, Andrea G; Avril, Norbert; Lam, Raymond; Iannone, Robert; Mozley, P David; Parkinson, Christine; Bergstrom, Donald; Sala, Evis; Sarker, Shah-Jalal; McNeish, Iain A; Brenton, James D
2014-05-15
Repeatability of baseline FDG-PET/CT measurements has not been tested in ovarian cancer. This dual-center, prospective study assessed variation in tumor 2[18F]fluoro-2-deoxy-D-glucose (FDG) uptake, tumor diameter, and tumor volume from sequential FDG-PET/CT and contrast-enhanced computed tomography (CECT) in patients with recurrent platinum-sensitive ovarian cancer. Patients underwent two pretreatment baseline FDG-PET/CT (n = 21) and CECT (n = 20) at two clinical sites with different PET/CT instruments. Patients were included if they had at least one target lesion in the abdomen with a standardized uptake value (SUV) maximum (SUVmax) of ≥ 2.5 and a long axis diameter of ≥ 15 mm. Two independent reading methods were used to evaluate repeatability of tumor diameter and SUV uptake: on site and at an imaging clinical research organization (CRO). Tumor volume reads were only performed by CRO. In each reading set, target lesions were independently measured on sequential imaging. Median time between FDG-PET/CT was two days (range 1-7). For site reads, concordance correlation coefficients (CCC) for SUVmean, SUVmax, and tumor diameter were 0.95, 0.94, and 0.99, respectively. Repeatability coefficients were 16.3%, 17.3%, and 8.8% for SUVmean, SUVmax, and tumor diameter, respectively. Similar results were observed for CRO reads. Tumor volume CCC was 0.99 with a repeatability coefficient of 28.1%. There was excellent test-retest repeatability for FDG-PET/CT quantitative measurements across two sites and two independent reading methods. Cutoff values for determining change in SUVmean, SUVmax, and tumor volume establish limits to determine metabolic and/or volumetric response to treatment in platinum-sensitive relapsed ovarian cancer. ©2014 American Association for Cancer Research.
Poon, Anna K; Meyer, Michelle L; Reaven, Gerald; Knowles, Joshua W; Selvin, Elizabeth; Pankow, James S; Couper, David; Loehr, Laura; Heiss, Gerardo
2018-06-01
The homeostatic model assessment of insulin resistance (HOMA-IR) and triglyceride (TG)/high-density lipoprotein cholesterol (HDL-C) ratio (TG/HDL-C) are insulin resistance indexes routinely used in clinical and population-based studies; however, their short-term repeatability is not well characterized. To quantify the short-term repeatability of insulin resistance indexes and their analytes, consisting of fasting glucose and insulin for HOMA-IR and TG and HDL-C for TG/HDL-C. Prospective cohort study. A total of 102 adults 68 to 88 years old without diabetes attended an initial examination and repeated examination (mean, 46 days; range, 28 to 102 days). Blood samples were collected, processed, shipped, and assayed following a standardized protocol. Repeatability was quantified using the intraclass correlation coefficient (ICC) and within-person coefficient of variation (CV). Minimum detectable change (MDC95) and minimum detectable difference with 95% confidence (MDD95) were quantified. For HOMA-IR, insulin, and fasting glucose, the ICCs were 0.70, 0.68, and 0.70, respectively; their respective within-person CVs were 30.4%, 28.8%, and 5.6%. For TG/HDL-C, TG, and HDL-C, the ICCs were 0.80, 0.68, and 0.91, respectively; their respective within-person CVs were 23.0%, 20.6%, and 8.2%. The MDC95 was 2.3 for HOMA-IR and 1.4 for TG/HDL-C. The MDD95 for a sample of n = 100 was 0.8 for HOMA-IR and 0.6 for TG/HDL-C. Short-term repeatability was fair to good for HOMA-IR and excellent for TG/HDL-C according to suggested benchmarks, reflecting the short-term variability of their analytes. These measurement properties can inform the use of these indexes in clinical and population-based studies.
High-speed and low-power repeater for VLSI interconnects
NASA Astrophysics Data System (ADS)
Karthikeyan, A.; Mallick, P. S.
2017-10-01
This paper proposes a repeater for boosting the speed of interconnects with low power dissipation. We have designed and implemented at 45 and 32 nm technology nodes. Delay and power dissipation performances are analyzed for various voltage levels at these technology nodes using Spice simulations. A significant reduction in delay and power dissipation are observed compared to a conventional repeater. The results show that the proposed high-speed low-power repeater has a reduced delay for higher load capacitance. The proposed repeater is also compared with LPTG CMOS repeater, and the results shows that the proposed repeater has reduced delay. The proposed repeater can be suitable for high-speed global interconnects and has the capacity to drive large loads.
Fitzgibbon, William E
2015-08-01
It is my distinct pleasure to introduce this volume honoring the 70th birthday of Professor Glenn F. Webb. The existence of this compiled volume is in itself a testimony of Glenn's dedication to, his pursuit of, and his achievement of scientific excellence. As we honor Glenn, we honor what is excellent in our profession. Aristotle clearly articulated his concept of excellence. ``We are what we repeatedly do. Excellence, then, is not an act, but a habit." As we look over the course of his career we observe ample evidence of Glenn Webb's habitual practice of excellence. Beginning with Glenn's first paper [1], one observes a constant stream of productivity and high impact work. Glenn has authored or co-authored over 160 papers, written one research monograph, and co-edited six volumes. He has delivered plenary lectures, colloquia, and seminars across the globe, and he serves on the editorial boards of 11 archival journals. He is a Fellow of the American Mathematical Society. Glenn's scientific career chronicles an evolution of scientific work that began with his interest in nonlinear semigroup theory and leads up to his current activity in biomedical mathematics. At each stage we see seminal contributions in the areas of nonlinear semigroups, functional differential equations, infinite dimensional dynamical systems, mathematical population dynamics, mathematical biology and biomedical mathematics. Glenn's work is distinguished by a clarity and accessibility of exposition, a precise identification and description of the problem or model under consideration, and thorough referencing. He uses elementary methods whenever possible but couples this with an ability to employ power abstract methods when necessitated by the problem.
Dermatocosmetologic aspects of treatment of basal-cell skin cancer
NASA Astrophysics Data System (ADS)
Geinitz, A. V.; Stranadko, Ye. F.; Yusupova, Zh. M.; Tkachenko, S. B.
2005-08-01
The obtained clinical findings demonstrate excellent results after surgical MSC treatment with the application of modem laser surgical technologies. All the operated patients were under oncologist"s control during 1.5-2.5 years. In 6 cases we observed topical recurrences which needed a repeated intervention. Thus, our experience of applying LPh for surgical treatment of basal-cell carcinomas of the head and neck dem- onstrate that in the analysed cases it is more reasonable to use two models of laser devices different in their physical parameters. These devices are used at different surgical stages so as to provide a precise effect in laser tumour va- porization within the borders of the healthy tissue, to make better vascular coagulation and laser smoothing of wound surface. Immediate, direct and long-term results of modern surgical lasers" application for treating skin BSC almost in all cases give good and excellent cosmetic effect after such intenventions.
Reliability of the ECHOWS Tool for Assessment of Patient Interviewing Skills.
Boissonnault, Jill S; Evans, Kerrie; Tuttle, Neil; Hetzel, Scott J; Boissonnault, William G
2016-04-01
History taking is an important component of patient/client management. Assessment of student history-taking competency can be achieved via a standardized tool. The ECHOWS tool has been shown to be valid with modest intrarater reliability in a previous study but did not demonstrate sufficient power to definitively prove its stability. The purposes of this study were: (1) to assess the reliability of the ECHOWS tool for student assessment of patient interviewing skills and (2) to determine whether the tool discerns between novice and experienced skill levels. A reliability and construct validity assessment was conducted. Three faculty members from the United States and Australia scored videotaped histories from standardized patients taken by students and experienced clinicians from each of these countries. The tapes were scored twice, 3 to 6 weeks apart. Reliability was assessed using interclass correlation coefficients (ICCs) and repeated measures. Analysis of variance models assessed the ability of the tool to discern between novice and experienced skill levels. The ECHOWS tool showed excellent intrarater reliability (ICC [3,1]=.74-.89) and good interrater reliability (ICC [2,1]=.55) as a whole. The summary of performance (S) section showed poor interrater reliability (ICC [2,1]=.27). There was no statistical difference in performance on the tool between novice and experienced clinicians. A possible ceiling effect may occur when standardized patients are not coached to provide complex and obtuse responses to interviewer questions. Variation in familiarity with the ECHOWS tool and in use of the online training may have influenced scoring of the S section. The ECHOWS tool demonstrates excellent intrarater reliability and moderate interrater reliability. Sufficient training with the tool prior to student assessment is recommended. The S section must evolve in order to provide a more discerning measure of interviewing skills. © 2016 American Physical Therapy Association.
Baert, Isabel A C; Lluch, Enrique; Struyf, Thomas; Peeters, Greta; Van Oosterwijck, Sophie; Tuynman, Joanna; Rufai, Salim; Struyf, Filip
2018-06-01
The therapeutic value of proprioceptive-based exercises in knee osteoarthritis (KOA) management warrants investigation of proprioceptive testing methods easily accessible in clinical practice. To estimate inter- and intrarater reliability of the knee joint position sense (KJPS) test and knee force sense (KFS) test in subjects with and without KOA. Cross-sectional test-retest design. Two blinded raters performed independently repeated measures of the KJPS and KFS test, using an analogue inclinometer and handheld dynamometer, respectively, in eight KOA patients (12 symptomatic knees) and 26 healthy controls (52 asymptomatic knees). Intraclass correlation coefficients (ICCs; model 2,1), standard error of measurement (SEM) and minimal detectable change with 95% confidence bounds (MDC 95 ) were calculated. For KJPS, results showed good to excellent test-retest agreement (ICCs 0.70-0.95 in KOA patients; ICCs 0.65-0.85 in healthy controls). A 2° measurement error (SEM 1°) was reported when measuring KJPS in multiple test positions and calculating mean repositioning error. Testing KOA patients pre and post therapy a repositioning error larger than 4° (MDC 95 ) is needed to consider true change. Measuring KFS using handheld dynamometry showed poor to fair interrater and poor to excellent intrarater reliability in subjects with and without KOA. Measuring KJPS in multiple test positions using an analogue inclinometer and calculating mean repositioning error is reliable and can be used in clinical practice. We do not recommend the use of the KFS test to clinicians. Further research is required to establish diagnostic accuracy and validity of our KJPS test in larger knee pain populations. Copyright © 2017 Elsevier Ltd. All rights reserved.
Taborri, Juri; Rossi, Stefano; Palermo, Eduardo; Patanè, Fabrizio; Cappa, Paolo
2014-09-02
In this work, we decided to apply a hierarchical weighted decision, proposed and used in other research fields, for the recognition of gait phases. The developed and validated novel distributed classifier is based on hierarchical weighted decision from outputs of scalar Hidden Markov Models (HMM) applied to angular velocities of foot, shank, and thigh. The angular velocities of ten healthy subjects were acquired via three uni-axial gyroscopes embedded in inertial measurement units (IMUs) during one walking task, repeated three times, on a treadmill. After validating the novel distributed classifier and scalar and vectorial classifiers-already proposed in the literature, with a cross-validation, classifiers were compared for sensitivity, specificity, and computational load for all combinations of the three targeted anatomical segments. Moreover, the performance of the novel distributed classifier in the estimation of gait variability in terms of mean time and coefficient of variation was evaluated. The highest values of specificity and sensitivity (>0.98) for the three classifiers examined here were obtained when the angular velocity of the foot was processed. Distributed and vectorial classifiers reached acceptable values (>0.95) when the angular velocity of shank and thigh were analyzed. Distributed and scalar classifiers showed values of computational load about 100 times lower than the one obtained with the vectorial classifier. In addition, distributed classifiers showed an excellent reliability for the evaluation of mean time and a good/excellent reliability for the coefficient of variation. In conclusion, due to the better performance and the small value of computational load, the here proposed novel distributed classifier can be implemented in the real-time application of gait phases recognition, such as to evaluate gait variability in patients or to control active orthoses for the recovery of mobility of lower limb joints.
Younossi, Zobair M; Afendy, Arian; Stepanova, Maria; Racila, Andrei; Nader, Fatema; Gomel, Rachel; Safer, Ricky; Lenderking, William R; Skalicky, Anne; Kleinman, Leah; Myers, Robert P; Subramanian, G Mani; McHutchison, John G; Levy, Cynthia; Bowlus, Christopher L; Kowdley, Kris; Muir, Andrew J
2017-11-20
Primary sclerosing cholangitis (PSC) is a chronic liver disease associated with inflammation and biliary fibrosis that leads to cholangitis, cirrhosis, and impaired quality of life. Our objective was to develop and validate a PSC-specific patient-reported outcome (PRO) instrument. We developed a 42-item PSC PRO instrument that contains two modules (Symptoms and Impact of Symptoms) and conducted an external validation. Reliability and validity were evaluated using clinical data and a battery of other validated instruments. Test-retest reliability was assessed in a subgroup of patients who repeated the PSC PRO after the first administration. One hundred two PSC subjects (44 ± 13 years; 32% male, 74% employed, 39% with cirrhosis, 14% with a history of decompensated cirrhosis, 38% history of depression, and 68% with inflammatory bowel disease [IBD]) completed PSC PRO and other PRO instruments (Short Form 36 V2 [SF-36], Chronic Liver Disease Questionnaire [CLDQ], Primary Biliary Cholangitis - 40 [PBC-40], and five dimensions [5-D Itch]). PSC PRO demonstrated excellent internal consistency (Cronbach alphas, 0.84-0.94) and discriminant validity (41 of 42 items had the highest correlations with their own domains). There were good correlations between PSC PRO domains and relevant domains of SF-36, CLDQ, and PBC-40 (R = 0.69-0.90; all P < 0.0001), but lower (R = 0.31-0.60; P < 0.001) with 5-D Itch. Construct validity showed that PSC PRO can differentiate patients according to the presence and severity of cirrhosis and history of depression (P < 0.05), but not by IBD (P > 0.05). Test-retest reliability was assessed in 53 subjects who repeated PSC PRO within a median (interquartile range) of 37 (27-47) days. There was excellent reliability for most domains with intraclass correlations (0.71-0.88; all P < 0.001). PSC PRO is a self-administered disease-specific instrument developed according to U.S. Food and Drug Administration guidelines. This preliminary validation study suggests good psychometric properties. Further validation of the instrument in a larger and more diverse sample of PSC patients is needed. (Hepatology 2017). © 2017 by the American Association for the Study of Liver Diseases.
Wheat, J S; Clarkson, S; Flint, S W; Simpson, C; Broom, D R
2018-05-21
Three dimensional (3D) surface imaging is a viable alternative to traditional body morphology measures, but the feasibility of using this technique with people with obesity has not been fully established. Therefore, the aim of this study was to investigate the validity, repeatability and acceptability of a consumer depth camera 3D surface imaging system in imaging people with obesity. The concurrent validity of the depth camera based system was investigated by comparing measures of mid-trunk volume to a gold-standard. The repeatability and acceptability of the depth camera system was assessed in people with obesity at a clinic. There was evidence of a fixed systematic difference between the depth camera system and the gold standard but excellent correlation between volume estimates (r 2 =0.997), with little evidence of proportional bias. The depth camera system was highly repeatable - low typical error (0.192L), high intraclass correlation coefficient (>0.999) and low technical error of measurement (0.64%). Depth camera based 3D surface imaging was also acceptable to people with obesity. It is feasible (valid, repeatable and acceptable) to use a low cost, flexible 3D surface imaging system to monitor the body size and shape of people with obesity in a clinical setting. Copyright © 2018 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.
Repeating and non-repeating fast radio bursts from binary neutron star mergers
NASA Astrophysics Data System (ADS)
Yamasaki, Shotaro; Totani, Tomonori; Kiuchi, Kenta
2018-04-01
Most fast radio bursts (FRB) do not show evidence of repetition, and such non-repeating FRBs may be produced at the time of a merger of binary neutron stars (BNS), provided that the BNS merger rate is close to the high end of the currently possible range. However, the merger environment is polluted by dynamical ejecta, which may prohibit the radio signal from propagating. We examine this by using a general-relativistic simulation of a BNS merger, and show that the ejecta appears about 1 ms after the rotation speed of the merged star becomes the maximum. Therefore there is a time window in which an FRB signal can reach outside, and the short duration of non-repeating FRBs can be explained by screening after ejecta formation. A fraction of BNS mergers may leave a rapidly rotating and stable neutron star, and such objects may be the origin of repeating FRBs like FRB 121102. We show that a merger remnant would appear as a repeating FRB on a time scale of ˜1-10 yr, and expected properties are consistent with the observations of FRB 121102. We construct an FRB rate evolution model that includes these two populations of repeating and non-repeating FRBs from BNS mergers, and show that the detection rate of repeating FRBs relative to non-repeating ones rapidly increases with improving search sensitivity. This may explain why only the repeating FRB 121102 was discovered by the most sensitive FRB search with Arecibo. Several predictions are made, including the appearance of a repeating FRB 1-10 yr after a BNS merger that is localized by gravitational waves and subsequent electromagnetic radiation.
Repeating and non-repeating fast radio bursts from binary neutron star mergers
NASA Astrophysics Data System (ADS)
Yamasaki, Shotaro; Totani, Tomonori; Kiuchi, Kenta
2018-06-01
Most fast radio bursts (FRB) do not show evidence of repetition, and such non-repeating FRBs may be produced at the time of a merger of binary neutron stars (BNS), provided that the BNS merger rate is close to the high end of the currently possible range. However, the merger environment is polluted by dynamical ejecta, which may prohibit the radio signal from propagating. We examine this by using a general-relativistic simulation of a BNS merger, and show that the ejecta appears about 1 ms after the rotation speed of the merged star becomes the maximum. Therefore there is a time window in which an FRB signal can reach outside, and the short duration of non-repeating FRBs can be explained by screening after ejecta formation. A fraction of BNS mergers may leave a rapidly rotating and stable neutron star, and such objects may be the origin of repeating FRBs like FRB 121102. We show that a merger remnant would appear as a repeating FRB on a time scale of ˜1-10 yr, and expected properties are consistent with the observations of FRB 121102. We construct an FRB rate evolution model that includes these two populations of repeating and non-repeating FRBs from BNS mergers, and show that the detection rate of repeating FRBs relative to non-repeating ones rapidly increases with improving search sensitivity. This may explain why only the repeating FRB 121102 was discovered by the most sensitive FRB search with Arecibo. Several predictions are made, including the appearance of a repeating FRB 1-10 yr after a BNS merger that is localized by gravitational waves and subsequent electromagnetic radiation.
Mansberger, Steven L.; Sheppler, Christina R.; McClure, Tina M.; VanAlstine, Cory L.; Swanson, Ingrid L.; Stoumbos, Zoey; Lambert, William E.
2013-01-01
Purpose: To report the psychometrics of the Glaucoma Treatment Compliance Assessment Tool (GTCAT), a new questionnaire designed to assess adherence with glaucoma therapy. Methods: We developed the questionnaire according to the constructs of the Health Belief Model. We evaluated the questionnaire using data from a cross-sectional study with focus groups (n = 20) and a prospective observational case series (n=58). Principal components analysis provided assessment of construct validity. We repeated the questionnaire after 3 months for test-retest reliability. We evaluated predictive validity using an electronic dosing monitor as an objective measure of adherence. Results: Focus group participants provided 931 statements related to adherence, of which 88.7% (826/931) could be categorized into the constructs of the Health Belief Model. Perceived barriers accounted for 31% (288/931) of statements, cues-to-action 14% (131/931), susceptibility 12% (116/931), benefits 12% (115/931), severity 10% (91/931), and self-efficacy 9% (85/931). The principal components analysis explained 77% of the variance with five components representing Health Belief Model constructs. Reliability analyses showed acceptable Cronbach’s alphas (>.70) for four of the seven components (severity, susceptibility, barriers [eye drop administration], and barriers [discomfort]). Predictive validity was high, with several Health Belief Model questions significantly associated (P <.05) with adherence and a correlation coefficient (R2) of .40. Test-retest reliability was 90%. Conclusion: The GTCAT shows excellent repeatability, content, construct, and predictive validity for glaucoma adherence. A multisite trial is needed to determine whether the results can be generalized and whether the questionnaire accurately measures the effect of interventions to increase adherence. PMID:24072942
Qin, Xuzhen; Rui, Jianzhong; Xia, Yong; Mu, Hong; Song, Sang Hoon; Raja Aziddin, Raja Elina; Miles, Gabrielle; Sun, Yuli
2018-01-01
Background The immunosuppressant drugs (ISDs), tacrolimus and cyclosporine, are vital for solid organ transplant patients to prevent rejection. However, toxicity is a concern, and absorption is highly variable across patients; therefore, ISD levels need to be precisely monitored. In the Asia-Pacific (APAC) region, tacrolimus and cyclosporine concentrations are typically measured using immunoassays. The objective of this study was to assess the analytical performance of Roche Elecsystacrolimus and cyclosporinee electrochemiluminescence immunoassays (ECLIAs). Methods This evaluation was performed in seven centers across China, South Korea, and Malaysia. Imprecision (repeatability and reproducibility), assay accuracy, and lot-to-lot reagent variability were tested. The Elecsys ECLIAs were compared with commercially available immunoassays (Architect, Dimension, and Viva-E systems) using whole blood samples from patients with various transplant types (kidney, liver, heart, and bone marrow). Results Coefficients of variation for repeatability and reproducibility were ≤5.4% and ≤12.4%, respectively, for the tacrolimus ECLIA, and ≤5.1% and ≤7.3%, respectively, for the cyclosporine ECLIA. Method comparisons of the tacrolimus ECLIA with Architect, Dimension, and Viva-E systems yielded slope values of 1.01, 1.14, and 0.897, respectively. The cyclosporine ECLIA showed even closer agreements with the Architect, Dimension, and Viva-E systems (slope values of 1.04, 1.04, and 1.09, respectively). No major differences were observed among the different transplant types. Conclusions The tacrolimus and cyclosporine ECLIAs demonstrated excellent precision and close agreement with other immunoassays tested. These results show that both assays are suitable for ISD monitoring in an APAC population across a range of different transplant types. PMID:29214751
The assessment of neuromuscular fatigue during 120 min of simulated soccer exercise.
Goodall, Stuart; Thomas, Kevin; Harper, Liam David; Hunter, Robert; Parker, Paul; Stevenson, Emma; West, Daniel; Russell, Mark; Howatson, Glyn
2017-04-01
This investigation examined the development of neuromuscular fatigue during a simulated soccer match incorporating a period of extra time (ET) and the reliability of these responses on repeated test occasions. Ten male amateur football players completed a 120 min soccer match simulation (SMS). Before, at half time (HT), full time (FT), and following a period of ET, twitch responses to supramaximal femoral nerve and transcranial magnetic stimulation (TMS) were obtained from the knee-extensors to measure neuromuscular fatigue. Within 7 days of the first SMS, a second 120 min SMS was performed by eight of the original ten participants to assess the reliability of the fatigue response. At HT, FT, and ET, reductions in maximal voluntary force (MVC; -11, -20 and -27%, respectively, P ≤ 0.01), potentiated twitch force (-15, -23 and -23%, respectively, P < 0.05), voluntary activation (FT, -15 and ET, -18%, P ≤ 0.01), and voluntary activation measured with TMS (-11, -15 and -17%, respectively, P ≤ 0.01) were evident. The fatigue response was robust across both trials; the change in MVC at each time point demonstrated a good level of reliability (CV range 6-11%; ICC 2,1 0.83-0.94), whilst the responses identified with motor nerve stimulation showed a moderate level of reliability (CV range 5-18%; ICC 2,1 0.63-0.89) and the data obtained with motor cortex stimulation showed an excellent level of reliability (CV range 3-6%; ICC 2,1 0.90-0.98). Simulated soccer exercise induces a significant level of fatigue, which is consistent on repeat tests, and involves both central and peripheral mechanisms.
Feasibility of online IMPT adaptation using fast, automatic and robust dose restoration
NASA Astrophysics Data System (ADS)
Bernatowicz, Kinga; Geets, Xavier; Barragan, Ana; Janssens, Guillaume; Souris, Kevin; Sterpin, Edmond
2018-04-01
Intensity-modulated proton therapy (IMPT) offers excellent dose conformity and healthy tissue sparing, but it can be substantially compromised in the presence of anatomical changes. A major dosimetric effect is caused by density changes, which alter the planned proton range in the patient. Three different methods, which automatically restore an IMPT plan dose on a daily CT image were implemented and compared: (1) simple dose restoration (DR) using optimization objectives of the initial plan, (2) voxel-wise dose restoration (vDR), and (3) isodose volume dose restoration (iDR). Dose restorations were calculated for three different clinical cases, selected to test different capabilities of the restoration methods: large range adaptation, complex dose distributions and robust re-optimization. All dose restorations were obtained in less than 5 min, without manual adjustments of the optimization settings. The evaluation of initial plans on repeated CTs showed large dose distortions, which were substantially reduced after restoration. In general, all dose restoration methods improved DVH-based scores in propagated target volumes and OARs. Analysis of local dose differences showed that, although all dose restorations performed similarly in high dose regions, iDR restored the initial dose with higher precision and accuracy in the whole patient anatomy. Median dose errors decreased from 13.55 Gy in distorted plan to 9.75 Gy (vDR), 6.2 Gy (DR) and 4.3 Gy (iDR). High quality dose restoration is essential to minimize or eventually by-pass the physician approval of the restored plan, as long as dose stability can be assumed. Motion (as well as setup and range uncertainties) can be taken into account by including robust optimization in the dose restoration. Restoring clinically-approved dose distribution on repeated CTs does not require new ROI segmentation and is compatible with an online adaptive workflow.
Ping, Hang; Xie, Hao; Xiang, Mingyu; Su, Bao-Lian; Wang, Yucheng; Zhang, Jinyong; Zhang, Fan; Fu, Zhengyi
2016-10-01
Biomineral formation processes in nature are temporally and spatially regulated under the functions of biomolecules in a confined space. It is potentially very productive to rationally design a mineralized system by taking into account confined space as well as biomolecules. The laboratory technique of "bacterial cell surface display" is an ideal platform to host catalytically active proteins in a three-dimensionally confined space. In the present study, aiming to regulate the synthesis of nanostructured TiO 2 anatase, repeating segments of silaffin were displayed on Escherichia coli surfaces through genetic manipulation. The displayed protein electrostatically interacted with a titanium source and catalyzed the hydrolysis of titanium dioxide precursors through hydrogen bonding interactions on the cell surface. In the subsequent calcination process, the genetically modified cells not only served as a framework for producing rod-shaped TiO 2 assembled by nanoparticles, but also provided a carbon source in situ . The size of nanoparticles was controlled by changing the number of tandem repeats of the protein segment. The as prepared TiO 2 anatase exhibited unique characteristics including nanosized anatase crystals, mesoporous structure and carbon coating. When tested as the anode electrode of a lithium-ion battery, it showed excellent lithium storage performance. The carbon coated anatase anode shows a higher specific capacity of 207 mA h g -1 after 200 cycles at a current rate of 1C and an ultra-long cycling lifetime of 5000 cycles with an outstanding retention capacity of 149 mA h g -1 at a higher rate of 10C. This bioprocess-inspired approach may help broaden the scope and impact of nanosized biominerals.
Ketogal: A Derivative Ketorolac Molecule with Minor Ulcerogenic and Renal Toxicity.
Russo, Roberto; De Caro, Carmen; Avallone, Bice; Magliocca, Salvatore; Nieddu, Maria; Boatto, Gianpiero; Troiano, Roberta; Cuomo, Rosario; Cirillo, Carla; Avagliano, Carmen; Cristiano, Claudia; La Rana, Giovanna; Sarnelli, Giovanni; Calignano, Antonio; Rimoli, Maria G
2017-01-01
Ketorolac is a powerful non-steroidal anti-inflammatory drug (NSAID), with a great analgesic activity, present on the Italian market since 1991. Despite the excellent therapeutic activity, the chronic use of ketorolac has long been limited owing to the high incidence of gastrointestinal and kidney side events. In our previous study, we demonstrated that ketorolac-galactose conjugate (ketogal), synthesized and tested in a single-dose study, was able to reduce ulcerogenicity, while preserving the high pharmacological efficacy of its parent drug. In this paper, in order to verify the suitability of this compound, for repeated administration, ex vivo experiments on naïve mice were performed. Mice were treated for 5 or 7 days with the highest doses of two drugs (ketorolac 10 mg/kg and ketogal 16.3 mg/kg), and the expression of both gastric COX-1 and PGsyn was evaluated. Results showed that oral ketorolac treatment significantly reduced both enzymes; surprisingly, oral treatment with ketogal did not produce significant variation in the expression of the two constitutive enzymes. Moreover, histological experiments on stomach and kidneys clearly indicated that repeated administration of ketogal induced lower toxicity than ketorolac. At same time, in vivo results clearly showed that both ketorolac and ketogal had a similar therapeutic activity in a model of inflammation and in pain perception. These effects were accompanied by the reduction of enzyme expression such as COX-2 and iNOS, and by the modulation of levels of nuclear NF-κB and cytosolic IκB-α in the inflamed paws. These very encouraging results demonstrate for the first time that ketogal could represent a valid and novel therapeutic alternative to the ketorolac and might pave the way for clinical studies.
Brocks, Dion R
2015-07-01
Pharmacokinetics can be a challenging topic to teach due to the complex relationships inherent between physiological parameters, mathematical descriptors and equations, and their combined impact on shaping the blood fluid concentration vs. time curves of drugs. A computer program was developed within Microsoft Excel for Windows, designed to assist in the instruction of basic pharmacokinetics within an entry-to-practice pharmacy class environment. The program is composed of a series of spreadsheets (modules) linked by Visual Basic for Applications, intended to illustrate the relationships between pharmacokinetic and in some cases physiological parameters, doses and dose rates and the drug blood fluid concentration vs. time curves. Each module is accompanied by a simulation user's guide, prompting the user to change specific independent parameters and then observe the impact of the change(s) on the drug concentration vs. time curve and on other dependent parameters. "Slider" (or "scroll") bars can be selected to readily see the effects of repeated changes on the dependencies. Topics covered include one compartment single dose administration (iv bolus, oral, short infusion), intravenous infusion, repeated doses, renal and hepatic clearance, nonlinear elimination, two compartment model, plasma protein binding and the relationship between pharmacokinetics and drug effect. The program has been used in various forms in the classroom over a number of years, with positive ratings generally being received from students for its use in the classroom. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Rantalainen, Timo; Gastin, Paul B; Spangler, Rhys; Wundersitz, Daniel
2018-09-01
The purpose of the present study was to evaluate the concurrent validity and test-retest repeatability of torso-worn IMU-derived power and jump height in a counter-movement jump test. Twenty-seven healthy recreationally active males (age, 21.9 [SD 2.0] y, height, 1.76 [0.7] m, mass, 73.7 [10.3] kg) wore an IMU and completed three counter-movement jumps a week apart. A force platform and a 3D motion analysis system were used to concurrently measure the jumps and subsequently derive power and jump height (based on take-off velocity and flight time). The IMU significantly overestimated power (mean difference = 7.3 W/kg; P < 0.001) compared to force-platform-derived power but good correspondence between methods was observed (Intra-class correlation coefficient [ICC] = 0.69). IMU-derived power exhibited good reliability (ICC = 0.67). Velocity-derived jump heights exhibited poorer concurrent validity (ICC = 0.72 to 0.78) and repeatability (ICC = 0.68) than flight-time-derived jump heights, which exhibited excellent validity (ICC = 0.93 to 0.96) and reliability (ICC = 0.91). Since jump height and power are closely related, and flight-time-derived jump height exhibits excellent concurrent validity and reliability, flight-time-derived jump height could provide a more desirable measure compared to power when assessing athletic performance in a counter-movement jump with IMUs.
Plain film measurement error in acute displaced midshaft clavicle fractures
Archer, Lori Anne; Hunt, Stephen; Squire, Daniel; Moores, Carl; Stone, Craig; O’Dea, Frank; Furey, Andrew
2016-01-01
Background Clavicle fractures are common and optimal treatment remains controversial. Recent literature suggests operative fixation of acute displaced mid-shaft clavicle fractures (DMCFs) shortened more than 2 cm improves outcomes. We aimed to identify correlation between plain film and computed tomography (CT) measurement of displacement and the inter- and intraobserver reliability of repeated radiographic measurements. Methods We obtained radiographs and CT scans of patients with acute DMCFs. Three orthopedic staff and 3 residents measured radiographic displacement at time zero and 2 weeks later. The CT measurements identified absolute shortening in 3 dimensions (by subtracting the length of the fractured from the intact clavicle). We then compared shortening measured on radiographs and shortening measured in 3 dimensions on CT. Interobserver and intraobserver reliability were calculated. Results We reviewed the fractures of 22 patients. Bland–Altman repeatability coefficient calculations indicated that radiograph and CT measurements of shortening could not be correlated owing to an unacceptable amount of measurement error (6 cm). Interobserver reliability for plain radiograph measurements was excellent (Cronbach α = 0.90). Likewise, intraobserver reliabilities for plain radiograph measurements as calculated with paired t tests indicated excellent correlation (p > 0.05 in all but 1 observer [p = 0.04]). Conclusion To establish shortening as an indication for DMCF fixation, reliable measurement tools are required. The low correlation between plain film and CT measurements we observed suggests further research is necessary to establish what imaging modality reliably predicts shortening. Our results indicate weak correlation between radiograph and CT measurement of acute DMCF shortening. PMID:27438054
Klement, R J; Hoerner-Rieber, J; Adebahr, S; Andratschke, N; Blanck, O; Boda-Heggemann, J; Duma, M; Eble, M J; Eich, H C; Flentje, M; Gerum, S; Hass, P; Henkenberens, C; Hildebrandt, G; Imhoff, D; Kahl, K H; Klass, N D; Krempien, R; Lohaus, F; Petersen, C; Schrade, E; Wendt, T G; Wittig, A; Guckenberger, M
2018-03-03
Stereotactic body radiotherapy (SBRT) for oligometastatic disease is characterized by an excellent safety profile; however, experiences are mostly based on treatment of one single metastasis. It was the aim of this study to evaluate safety and efficacy of SBRT for multiple pulmonary metastases. This study is based on a retrospective database of the DEGRO stereotactic working group, consisting of 637 patients with 858 treatments. Cox regression and logistic regression were used to analyze the association between the number of SBRT treatments or the number and the timing of repeat SBRT courses with overall survival (OS) and the risk of early death. Out of 637 patients, 145 patients were treated for multiple pulmonary metastases; 88 patients received all SBRT treatments within one month whereas 57 patients were treated with repeat SBRT separated by at least one month. Median OS for the total patient population was 23.5 months and OS was not significantly influenced by the overall number of SBRT treatments or the number and timing of repeat SBRT courses. The risk of early death within 3 and 6 months was not increased in patients treated with multiple SBRT treatments, and no grade 4 or grade 5 toxicity was observed in these patients. In appropriately selected patients, synchronous SBRT for multiple pulmonary oligometastases and repeat SBRT may have a comparable safety and efficacy profile compared to SBRT for one single oligometastasis. Copyright © 2018 Elsevier B.V. All rights reserved.
An integrated molecular cytogenetic map of Cucumis sativus L. chromosome 2.
Han, Yonghua; Zhang, Zhonghua; Huang, Sanwen; Jin, Weiwei
2011-01-27
Integration of molecular, genetic and cytological maps is still a challenge for most plant species. Recent progress in molecular and cytogenetic studies created a basis for developing integrated maps in cucumber (Cucumis sativus L.). In this study, eleven fosmid clones and three plasmids containing 45S rDNA, the centromeric satellite repeat Type III and the pericentriomeric repeat CsRP1 sequences respectively were hybridized to cucumber metaphase chromosomes to assign their cytological location on chromosome 2. Moreover, an integrated molecular cytogenetic map of cucumber chromosomes 2 was constructed by fluorescence in situ hybridization (FISH) mapping of 11 fosmid clones together with the cucumber centromere-specific Type III sequence on meiotic pachytene chromosomes. The cytogenetic map was fully integrated with genetic linkage map since each fosmid clone was anchored by a genetically mapped simple sequence repeat marker (SSR). The relationship between the genetic and physical distances along chromosome was analyzed. Recombination was not evenly distributed along the physical length of chromosome 2. Suppression of recombination was found in centromeric and pericentromeric regions. Our results also indicated that the molecular markers composing the linkage map for chromosome 2 provided excellent coverage of the chromosome.
Maas, M; Akkerman, E M; Venema, H W; Stoker, J; Den Heeten, G J
2001-01-01
The purpose of this work was to explore the reproducibility of fat-fraction measurements using Dixon quantitative chemical shift imaging (QCSI) in the lumbar spine (L3, L4, and L5) of healthy volunteers. Sixteen healthy volunteers were examined at 1.5 T two times to obtain a repeated measurement in the same slice and a third time in three parallel slices. Single slice, two point Dixon SE (TR/TE 2,500/22.3) sequences were used, from which fat-fraction images were calculated. The fat-fraction results are presented as averages over regions of interest, which were derived from the contours of the vertebrae. Reproducibility measures related to repeated measurements on different days, slice position, and contour drawing were calculated. The mean fat fraction was 0.37 (SD 0.08). The SD due to repeated measurement was small (sigmaR = 0.013-0.032), almost all of which can be explained by slice-(re)-positioning errors. When used to evaluate the same person longitudinally in time, Dixon QCSI fat-fraction measurement has an excellent reproducibility. It is a powerful noninvasive tool in the evaluation of bone marrow composition.
Rechargeable LiNiO2/carbon cells
NASA Astrophysics Data System (ADS)
Dahn, J. R.; von Sacken, U.; Juzkow, M. W.; Al-Janaby, H.
1991-08-01
Rechargeable cells can be made using two different intercalation compounds, in which the chemical potential of the intercalant differs by several eV, for the electrodes. The factors that play a role in the selection of appropriate lithium intercalation compounds for such cells are discussed. For the ease of cell assembly, the cathode should be stable in air when it is fully intercalated, like LiNiO2. For the anode, the chemical potential of the intercalated Li should be close to that of Li metal, like it is in Li(x)C6. The intercalation of Li in LiNiO2 is discussed, and then in petroleum coke. Then, it is shown that LiNiO2/coke cells have high energy density, long cycle life, excellent high-temperature performance, low self-discharge rates, can be repeatedly discharged to zero volts without damage, and are easily fabricated. It is considered that this type of cell shows far more promise for widespread applications than traditional secondary Li cells using metallic Li anodes.
Galileo probe lithium-sulfur dioxide cell life testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hofland, L.M.; Stofel, E.J.; Taenaka, R.K.
Several hundred D-sized, Li/SO{sub 2} battery cells have been in a carefully controlled quiescent storage test for up to 14 years, starting at Honeywell but completing at the NASA Ames Research Center, in support of the Atmospheric Probe portion of the Galileo Mission to the planet Jupiter. This population of cells includes similar samples from 8 different manufacturing lots; the earliest from October 1981, the latest from October 1988. The baseline samples have been divided among several storage chambers, each having its own constant temperature, respectively set between 0 to 40 C. Non-invasive measurements have been made repeatedly of openmore » circuit voltage and internal resistance (at 1,000 Hz). At intervals, a small portion of the cells has been removed from storage and fully discharged under repetitive conditions, thus assessing any storage related loss of discharge capacity. The results show that for storage up to 20 C the cells have excellent stability. Above 20 C noticeable degradation occurs.« less
Sol-Gel Synthesis of Carbon Xerogel-ZnO Composite for Detection of Catechol
Li, Dawei; Zang, Jun; Zhang, Jin; Ao, Kelong; Wang, Qingqing; Dong, Quanfeng; Wei, Qufu
2016-01-01
Carbon xerogel-zinc oxide (CXZnO) composites were synthesized by a simple method of sol-gel condensation polymerization of formaldehyde and resorcinol solution containing zinc salt followed by drying and thermal treatment. ZnO nanoparticles were observed to be evenly dispersed on the surfaces of the carbon xerogel microspheres. The as-prepared CXZnO composites were mixed with laccase (Lac) and Nafion to obtain a mixture solution, which was further modified on an electrode surface to construct a novel biosensing platform. Finally, the prepared electrochemical biosensor was employed to detect the environmental pollutant, catechol. The analysis result was satisfactory, the sensor showed excellent electrocatalysis towards catechol with high sensitivity (31.2 µA·mM−1), a low detection limit (2.17 µM), and a wide linear range (6.91–453 µM). Moreover, the biosensor also displayed favorable repeatability, reproducibility, selectivity, and stability besides being successfully used in the trace detection of catechol existing in lake water environments. PMID:28773407
Application of molecularly imprinted polymers to selective removal of clofibric acid from water.
Dai, Chaomeng; Zhang, Juan; Zhang, Yalei; Zhou, Xuefei; Liu, Shuguang
2013-01-01
A new molecularly imprinted polymer (MIP) adsorbent for clofibric acid (CA) was prepared by a non-covalent protocol. Characterization of the obtained MIP was achieved by scanning electron microscopy (SEM) and nitrogen sorption. Sorption experimental results showed that the MIP had excellent binding affinity for CA and the adsorption of CA by MIP was well described by pseudo-second-order model. Scatchard plot analysis revealed that two classes of binding sites were formed in the MIP with dissociation constants of 7.52 ± 0.46 mg L(-1) and 114 ± 4.2 mg L(-1), respectively. The selectivity of MIP demonstrated higher affinity for CA over competitive compound than that of non-imprinted polymers (NIP). The MIP synthesized was used to remove CA from spiked surface water and exhibited significant binding affinity towards CA in the presence of total dissolved solids (TDS). In addition, MIP reusability was demonstrated for at least 12 repeated cycles without significant loss in performance.
Superparamagnetic IPN gels of carrageenan/PHEMA excelling in shape retention.
Tsuru, Takahiro; Sugimura, Kazuki; Nishio, Yoshiyuki
2017-12-15
Iron oxide nanoparticles-incorporated carrageenan (CAR)/PHEMA composites of interpenetrating network (IPN) type were successfully prepared by in situ ferrite synthesis in the polymer network. The IPN structure was constructed at CAR/PHEMA compositions of 15/85 and 40/60 (wt/wt) by polymerization and cross-linking of 2-hydroxyethylmethacrylate as an impregnating solvent of CAR gels. As a result of this IPN construction, the composites were firm and showed a good shape-retentivity in their gelatinous state. SQUID magnetometry and X-ray diffractometry were conducted for evaluation of the magnetic property of the inorganic-hybridized IPN composites. Magnetite particles with 10-30nm sizes were distributed inside the IPNs treated with the repeatable ferrite synthesis; thereby, the hybrids displayed a superparamagnetic character at ambient temperature. Specifically, the 40/60 CAR/PHEMA IPN imparted a practically passable value (10-15emu (g sample) -1 ) of saturation magnetization. The present IPN system offers a potential for application as a biocompatible magnetic material used in hydro-surroundings. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zheng, Qiaofeng; Han, Baoguo; Ou, Jinping
2018-07-01
In this paper, a ship-bridge collision monitoring system based on flexible quantum tunneling composite (QTC) with cushioning capability is proposed by investigating the sensing capability and positioning capability of QTC to collisions. QTCs with different rubber matrix and thickness were fabricated, and collision tests between steel ball and QTCs sensors were designed to simulate ship-bridge collision. The results show that QTCs have a sensing range over 50 MPa with stress resolution ranging between 0.017 and 0.13 MPa, enough to achieve the full-time monitoring of ship-bridge collision. The system has instant and repeatable respond to impact load, and can accurately position the collisions. Moreover, QTC can remarkably absorb the kinetic energy during collisions, exhibiting excellent cushioning capability. These findings indicate the proposed ship-bridge collision monitoring system has great potential for application to detecting collision information such as collision occurrence and duration, impact load and collision location, as well as providing basis for citizen evacuation, post-accident damage estimation and rescue strategy.
Wearable woven supercapacitor fabrics with high energy density and load-bearing capability.
Shen, Caiwei; Xie, Yingxi; Zhu, Bingquan; Sanghadasa, Mohan; Tang, Yong; Lin, Liwei
2017-10-30
Flexible power sources with load bearing capability are attractive for modern wearable electronics. Here, free-standing supercapacitor fabrics that can store high electrical energy and sustain large mechanical loads are directly woven to be compatible with flexible systems. The prototype with reduced package weight/volume provides an impressive energy density of 2.58 mWh g -1 or 3.6 mWh cm -3 , high tensile strength of over 1000 MPa, and bearable pressure of over 100 MPa. The nanoporous thread electrodes are prepared by the activation of commercial carbon fibers to have three-orders of magnitude increase in the specific surface area and 86% retention of the original strength. The novel device configuration woven by solid electrolyte-coated threads shows excellent flexibility and stability during repeated mechanical bending tests. A supercapacitor watchstrap is used to power a liquid crystal display as an example of load-bearing power sources with various form-factor designs for wearable electronics.
A simple experimental method to study depigmenting agents.
Abella, M L; de Rigal, J; Neveux, S
2007-08-01
The first objective of the study was to verify that a controlled UV exposure of four areas of the forearms together with randomized product application enabled to compare treatment efficacy and then to compare the depigmenting efficacy of different products with a simple experimental method. Sixteen volunteers received 0.7 minimal erythermal dose for four consecutive days. Products tested were ellagic acid (0.5%), vitamin C (5%) and C8-LHA (2%). Product application started 72 h post last exposure, was repeated for 42 days, the control zone being exposed, non-treated. Colour measurements included Chromameter, Chromasphere, Spectro-colorimeter and visual assessment. Comparison of colour values at day 1 and at day 7 showed that all zones were comparably tanned, allowing a rigorous comparison of the treatments. We report a new simple experimental model, which enables the rapid comparison of different depigmenting products. The efficacy and good tolerance of C8-LHA make it an excellent candidate for the treatment of hyperpigmentory disorders.
André, L; Pauss, A; Ribeiro, T
2017-03-01
The chemical oxygen demand (COD) is an essential parameter in waste management, particularly when monitoring wet anaerobic digestion processes. An adapted method to determine COD was developed for solid waste (total solids >15%). This method used commercial COD tubes and did not require sample dilution. A homemade plastic weighing support was used to transfer the solid sample into COD tubes. Potassium hydrogen phthalate and glucose used as standards showed an excellent repeatability. A small underestimation of the theoretical COD value (standard values around 5% lower than theoretical values) was also observed, mainly due to the intrinsic COD of the weighing support and to measurement uncertainties. The adapted COD method was tested using various solid wastes in the range of 1-8 mg COD , determining the COD of dried and ground cellulose, cattle manure, straw and a mixed-substrate sample. This new adapted method could be used to monitor and design dry anaerobic digestion processes.
Application of Molecularly Imprinted Polymers to Selective Removal of Clofibric Acid from Water
Dai, Chaomeng; Zhang, Juan; Zhang, Yalei; Zhou, Xuefei; Liu, Shuguang
2013-01-01
A new molecularly imprinted polymer (MIP) adsorbent for clofibric acid (CA) was prepared by a non-covalent protocol. Characterization of the obtained MIP was achieved by scanning electron microscopy (SEM) and nitrogen sorption. Sorption experimental results showed that the MIP had excellent binding affinity for CA and the adsorption of CA by MIP was well described by pseudo-second-order model. Scatchard plot analysis revealed that two classes of binding sites were formed in the MIP with dissociation constants of 7.52±0.46 mg L−1 and 114±4.2 mg L−1, respectively. The selectivity of MIP demonstrated higher affinity for CA over competitive compound than that of non-imprinted polymers (NIP). The MIP synthesized was used to remove CA from spiked surface water and exhibited significant binding affinity towards CA in the presence of total dissolved solids (TDS). In addition, MIP reusability was demonstrated for at least 12 repeated cycles without significant loss in performance. PMID:24205143
NASA Astrophysics Data System (ADS)
Li, Desheng; Wang, Dongya; Rui, Kun; Ma, Zhongyuan; Xie, Ling; Liu, Jinhua; Zhang, Yu; Chen, Runfeng; Yan, Yan; Lin, Huijuan; Xie, Xiaoji; Zhu, Jixin; Huang, Wei
2018-04-01
The emerging wearable and foldable electronic devices drive the development of flexible lithium ion batteries (LIBs). Carbon materials are considered as one of the most promising electrode materials for LIBs due to their light weight, low cost and good structural stability against repeated deformations. However, the specific capacity, rate capability and long-term cycling performance still need to be improved for their applications in next-generation LIBs. Herein, we report a facile approach for immobilizing phosphorus into a large-area carbon nanosheets/nanofibers interwoven free-standing paper for LIBs. As an anode material for LIBs, it shows high reversible capacity of 1100 mAh g-1 at a current density of 200 mA g-1, excellent rate capabilities (e.g., 200 mAh g-1 at 20,000 mA g-1). Even at a high current density of 1000 mA g-1, it still maintains a superior specific capacity of 607 mAh g-1 without obvious decay.
Nanomolar detection of methylparaben by a cost-effective hemoglobin-based biosensor.
Hajian, A; Ghodsi, J; Afraz, A; Yurchenko, O; Urban, G
2016-12-01
This work describes the development of a new biosensor for methylparaben determination using electrocatalytic properties of hemoglobin in the presence of hydrogen peroxide. The voltammetric oxidation of methylparaben by the proposed biosensor in phosphate buffer (pH=7.0), a physiological pH, was studied and it was confirmed that methylparaben undergoes a one electron-one proton reaction in a diffusion-controlled process. The biosensor was fabricated by carbon paste electrode modified with hemoglobin and multiwalled carbon nanotube. Based on the excellent electrochemical properties of the modified electrode, a sensitive voltammetric method was used for determination of methylparaben within a linear range from 0.1 to 13μmolL(-1) and detection limit of 25nmolL(-1). The developed biosensor possessed accurate and rapid response to methylparaben and showed good sensitivity, stability, and repeatability. Finally, the applicability of the proposed biosensor was verified by methylparaben evaluation in various real samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Porous carbon-free SnSb anodes for high-performance Na-ion batteries
NASA Astrophysics Data System (ADS)
Choi, Jeong-Hee; Ha, Choong-Wan; Choi, Hae-Young; Seong, Jae-Wook; Park, Cheol-Min; Lee, Sang-Min
2018-05-01
A simple melt-spinning/chemical-etching process is developed to create porous carbon-free SnSb anodes. Sodium ion batteries (SIBs) incorporating these anodes exhibit excellent electrochemical performances by accomodating large volume changes during repeated cycling. The porous carbon-free SnSb anode produced by the melt-spinning/chemical-etching process shows a high reversible capacity of 481 mAh g-1, high ICE of 80%, stable cyclability with a high capacity retention of 99% after 100 cycles, and a fast rate capability of 327 mAh g-1 at 4C-rate. Ex-situ X-ray diffraction and high resolution-transmission electron microscopy analyses demonstrate that the synthesized porous carbon-free SnSb anodes involve the highly reversible reaction with sodium through the conversion and recombination reactions during sodiation/desodiation process. The novel and simple melt-spinning/chemical-etching synthetic process represents a technological breakthrough in the commercialization of Na alloy-able anodes for SIBs.
Wang, Yongcheng; Tang, Jing; Peng, Zheng; Wang, Yuhang; Jia, Dingsi; Kong, Biao; Elzatahry, Ahmed A; Zhao, Dongyuan; Zheng, Gengfeng
2014-06-11
We report the development of a multifunctional, solar-powered photoelectrochemical (PEC)-pseudocapacitive-sensing material system for simultaneous solar energy conversion, electrochemical energy storage, and chemical detection. The TiO2 nanowire/NiO nanoflakes and the Si nanowire/Pt nanoparticle composites are used as photoanodes and photocathodes, respectively. A stable open-circuit voltage of ∼0.45 V and a high pseudocapacitance of up to ∼455 F g(-1) are obtained, which also exhibit a repeating charging-discharging capability. The PEC-pseudocapacitive device is fully solar powered, without the need of any external power supply. Moreover, this TiO2 nanowire/NiO nanoflake composite photoanode exhibits excellent glucose sensitivity and selectivity. Under the sun light illumination, the PEC photocurrent shows a sensitive increase upon different glucose additions. Meanwhile in the dark, the open-circuit voltage of the charged pseudocapacitor also exhibits a corresponding signal over glucose analyte, thus serving as a full solar-powered energy conversion-storage-utilization system.
Li, Fei; Yu, Fengshou; Du, Jian; Wang, Yong; Zhu, Yong; Li, Xiaona; Sun, Licheng
2017-10-18
Water splitting mediated by electron-coupled-proton buffer (ECPB) provides an efficient way to avoid gas mixing by separating oxygen evolution from hydrogen evolution in space and time. Though electrochemical and photoelectrochemcial water oxidation have been incorporated in such a two-step water splitting system, alternative ways to reduce the cost and energy input for decoupling two half-reactions are desired. Herein, we show the feasibility of photocatalytic oxygen evolution in a powder system with BiVO 4 as a photocatalyst and polyoxometalate H 3 PMo 12 O 40 as an electron and proton acceptor. The resulting reaction mixture was allowed to be directly used for the subsequent hydrogen evolution with the reduced H 3 PMo 12 O 40 as electron and proton donors. Our system exhibits excellent stability in repeated oxygen and hydrogen evolution, which brings considerable convenience to decoupled water splitting. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fucoxanthin bioavailability from fucoxanthin-fortified milk: In vivo and in vitro study.
Mok, Il-Kyoon; Lee, Jae Kwon; Kim, Jeong Hwa; Pan, Cheol-Ho; Kim, Sang Min
2018-08-30
Our previous study reported the improved stability of fucoxanthin (FX) fortified in whole milk (WM) and skimmed milk (SM). In this study, in vivo and in vitro FX bioavailability were investigated using FX-fortified milk (FX-SM and FX-WM) and microalga Phaeodactylum tricornutum biomass (Pt-powder). Organ tissue accumulation of FX and its metabolites (FXOH: fucoxanthinol, AXA: amarouciaxanthin A) after repeated oral administration was in the following order: FX-SM > FX-WM > Pt-powder. In vivo pharmacokinetic study with a single oral administration also demonstrated that the absorption of FXOH and AXA was the highest for FX-SM. To reinforce the in vivo results, in vitro-simulated digestion and Caco-2 cell uptake assays were performed, which revealed that FX-SM showed the highest FX bioaccessibility (release from food matrices) and cellular uptake efficiency of FX and FXOH. In conclusion, skimmed milk was validated as an excellent food matrix for FX application in terms of stability and bioavailability. Copyright © 2018 Elsevier Ltd. All rights reserved.
Zhang, Gaosheng; Ren, Zongming; Zhang, Xiwang; Chen, Jing
2013-08-01
To obtain a highly efficient and low-cost adsorbent for arsenic removal from water, a novel nanostructured Fe-Cu binary oxide was synthesized via a facile co-precipitation method. Various techniques including BET surface area measurement, powder XRD, SEM, and XPS were used to characterize the synthetic Fe-Cu binary oxide. It showed that the oxide was poorly crystalline, 2-line ferrihydrite-like and was aggregated with many nanosized particles. Laboratory experiments were performed to investigate adsorption kinetics, adsorption isotherms, pH adsorption edge and regeneration of spent adsorbent. The results indicated that the Fe-Cu binary oxide with a Cu: Fe molar ratio of 1:2 had excellent performance in removing both As(V) and As(III) from water, and the maximal adsorption capacities for As(V) and As(III) were 82.7 and 122.3 mg/g at pH 7.0, respectively. The values are favorable, compared to those reported in the literature using other adsorbents. The coexisting sulfate and carbonate had no significant effect on arsenic removal. However, the presence of phosphate obviously inhibited the arsenic removal, especially at high concentrations. Moreover, the Fe-Cu binary oxide could be readily regenerated using NaOH solution and be repeatedly used. The Fe-Cu binary oxide could be a promising adsorbent for both As(V) and As(III) removal because of its excellent performance, facile and low-cost synthesis process, and easy regeneration. Copyright © 2013 Elsevier Ltd. All rights reserved.
Amino acid sequence analysis of the annexin super-gene family of proteins.
Barton, G J; Newman, R H; Freemont, P S; Crumpton, M J
1991-06-15
The annexins are a widespread family of calcium-dependent membrane-binding proteins. No common function has been identified for the family and, until recently, no crystallographic data existed for an annexin. In this paper we draw together 22 available annexin sequences consisting of 88 similar repeat units, and apply the techniques of multiple sequence alignment, pattern matching, secondary structure prediction and conservation analysis to the characterisation of the molecules. The analysis clearly shows that the repeats cluster into four distinct families and that greatest variation occurs within the repeat 3 units. Multiple alignment of the 88 repeats shows amino acids with conserved physicochemical properties at 22 positions, with only Gly at position 23 being absolutely conserved in all repeats. Secondary structure prediction techniques identify five conserved helices in each repeat unit and patterns of conserved hydrophobic amino acids are consistent with one face of a helix packing against the protein core in predicted helices a, c, d, e. Helix b is generally hydrophobic in all repeats, but contains a striking pattern of repeat-specific residue conservation at position 31, with Arg in repeats 4 and Glu in repeats 2, but unconserved amino acids in repeats 1 and 3. This suggests repeats 2 and 4 may interact via a buried saltbridge. The loop between predicted helices a and b of repeat 3 shows features distinct from the equivalent loop in repeats 1, 2 and 4, suggesting an important structural and/or functional role for this region. No compelling evidence emerges from this study for uteroglobin and the annexins sharing similar tertiary structures, or for uteroglobin representing a derivative of a primordial one-repeat structure that underwent duplication to give the present day annexins. The analyses performed in this paper are re-evaluated in the Appendix, in the light of the recently published X-ray structure for human annexin V. The structure confirms most of the predictions and shows the power of techniques for the determination of tertiary structural information from the amino acid sequences of an aligned protein family.
NASA Astrophysics Data System (ADS)
Dominguez, L. A.; Taira, T.; Hjorleifsdottir, V.; Santoyo, M. A.
2015-12-01
Repeating earthquake sequences are sets of events that are thought to rupture the same area on the plate interface and thus provide nearly identical waveforms. We systematically analyzed seismic records from 2001 through 2014 to identify repeating earthquakes with highly correlated waveforms occurring along the subduction zone of the Cocos plate. Using the correlation coefficient (cc) and spectral coherency (coh) of the vertical components as selection criteria, we found a set of 214 sequences whose waveforms exceed cc≥95% and coh≥95%. Spatial clustering along the trench shows large variations in repeating earthquakes activity. Particularly, the rupture zone of the M8.1, 1985 earthquake shows an almost absence of characteristic repeating earthquakes, whereas the Guerrero Gap zone and the segment of the trench close to the Guerrero-Oaxaca border shows a significantly larger number of repeating earthquakes sequences. Furthermore, temporal variations associated to stress changes due to major shows episodes of unlocking and healing of the interface. Understanding the different components that control the location and recurrence time of characteristic repeating sequences is a key factor to pinpoint areas where large megathrust earthquakes may nucleate and consequently to improve the seismic hazard assessment.
Results of the supplementary comparison SIM.M.FF-S12 for volume of liquids at 20 L
NASA Astrophysics Data System (ADS)
Maldonado, M.; Castillo, E.; Rodríguez, L. D.
2018-01-01
A supplementary comparison was performed in order to compare national measurement systems to determine volume of liquids, particularly at fixed volume of 20 L. The participants were CENAM (Mexico), LACOMET (Costa Rica) and RECOPE (Costa Rica). The measurements were carried out from October 2016 to June 2017. The chosen value of volume (20 L) is representative of the Calibration and Measurement Capabilities (CMCs) declared by the three participants. The transfer standard (TS) was a stainless steel pipette for volume at 20 L. Prior to the beginning of the comparison, the TS was tested by CENAM. The results of the test phase showed excellent values for both repeatability and reproducibility. During the SIM.M.FF-S12, the results of the laboratories showed good agreement with the reference values. The best estimation of the measurands, as reported by the participants, showed a +/- 0.0022 % as the largest difference among the laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Gamba, Thiago O; Oliveira, Matheus L; Flores, Isadora L; Cruz, Adriana D; Almeida, Solange M; Haiter-Neto, Francisco; Lopes, Sérgio L P C
2014-03-01
To compare dental plaster model (DPM) and cone-beam computed tomography (CBCT) in the measurement of the dental arches, and investigate whether CBCT image artifacts compromise the reliability of such measurements. Twenty patients were divided into two groups based on the presence or absence of metallic restorations in the posterior teeth. Both dental arches of the patients were scanned with the CBCT unit i-CAT, and DPMs were obtained. Two examiners obtained eight arch measurements on the CBCT images and DPMs and repeated this procedure 15 days later. The arch measurements of each patient group were compared separately by the Wilcoxon rank sum (Mann-Whitney U) test, with a significance level of 5% (α = .05). Intraclass correlation measured the level of intraobserver agreement. Patients with healthy teeth showed no significant difference between all DPM and CBCT arch measurements (P > .05). Patients with metallic restoration showed significant difference between DPM and CBCT for the majority of the arch measurements (P > .05). The two examiners showed excellent intraobserver agreement for both measuring methods with intraclass correlation coefficient higher than 0.95. CBCT provided the same accuracy as DPM in the measurement of the dental arches, and was negatively influenced by the presence of image artifacts.
Osteo-odonto keratoprosthesis: systematic review of surgical outcomes and complication rates.
Tan, Anna; Tan, Donald T; Tan, Xiao-Wei; Mehta, Jodhbir S
2012-01-01
Case series on osteo-odonto keratoprosthesis (OOKP) published in English from 1950-June 2010 were identified in Medline/PubMed. Indications for surgery, visual acuity, anatomical survival, complication and repeat surgery rates were compared among the different studies. Our own case series is a retrospective review of all OOKP surgeries performed in our center from February 2004-July 2011. Eight case series including our own were systematically reviewed. Sample sizes ranged from 4-181 eyes. The most common indications for surgery were severe cases of Stevens-Johnson syndrome and thermal and chemical burns that were unamenable to other forms of surgery or had had previous surgical failure. Anatomical survival rate in all the studies was 87.8% (range 67-100%) at 5 years, and three studies showed survival rates of 81.0% (range 65-98%) at 20 years. Visual acuity was more than 6/18 in 52% (range 46-72%) of the eyes with OOKP surgery. The most common intraoperative complication was vitreous hemorrhage (0-52%) and the most common long-term blinding complication was glaucoma (7-47%). Endophthalmitis rates ranged from 2-8%. The most common repeat surgical procedure was mucosal trimming due to mucosal overgrowth at the optical cylinder and mucosal grafting for extrusion of the OOKP or mucosal ulceration. Of the available biological and synthetic keratoprosthesis, OOKP appears to be an excellent option for the treatment of end-stage corneal diseases. Copyright © 2012 Elsevier Inc. All rights reserved.
Liu, Pengpeng; Ge, Xingbo; Wang, Rongyue; Ma, Houyi; Ding, Yi
2009-01-06
Ultrathin Pt films from one to several atomic layers are successfully decorated onto nanoporous gold (NPG) membranes by utilizing under potential deposition (UPD) of Cu onto Au or Pt surfaces, followed by in situ redox replacement reaction (RRR) of UPD Cu by Pt. The thickness of Pt layers can be controlled precisely by repeating the Cu-UPD-RRR cycles. TEM observations coupled with electrochemical testing suggest that the morphology of Pt overlayers changes from an ultrathin epitaxial film in the case of one or two atomic layers to well-dispersed nanoislands in the case of four and more atomic layers. Electron diffraction (ED) patterns confirm that the as-prepared NPG-Pt membranes maintain a single-crystalline structure, even though the thickness of Pt films reaches six atomic layers, indicating the decorated Pt films hold the same crystallographic relationship to the NPG substrate during the entire fabrication process. Due to the regular modulation of Pt utilization, the electrocatalytic activity of NPG-Pt exhibits interesting surface structure dependence in methanol, ethanol, and CO electrooxidation reactions. These novel bimetallic nanocatalysts show excellent electrocatalytic activity and much enhanced poison tolerance as compared to the commercial Pt/C catalysts. The success in the fabrication of NPG-Pt-type materials provides a new path to prepare electrocatalysts with ultralow Pt loading and high Pt utilization, which is of great significance in energy-related applications, such as direct alcohol fuel cells (DAFCs).
Instrumented figure skating blade for measuring on-ice skating forces
NASA Astrophysics Data System (ADS)
Acuña, S. A.; Smith, D. M.; Robinson, J. M.; Hawks, J. C.; Starbuck, P.; King, D. L.; Ridge, S. T.; Charles, S. K.
2014-12-01
Competitive figure skaters experience substantial, repeated impact loading during jumps and landings. Although these loads, which are thought to be as high as six times body weight, can lead to overuse injuries, it is not currently possible to measure these forces on-ice. Consequently, efforts to improve safety for skaters are significantly limited. Here we present the development of an instrumented figure skating blade for measuring forces on-ice. The measurement system consists of strain gauges attached to the blade, Wheatstone bridge circuit boards, and a data acquisition device. The system is capable of measuring forces in the vertical and horizontal directions (inferior-superior and anterior-posterior directions, respectively) in each stanchion with a sampling rate of at least 1000 Hz and a resolution of approximately one-tenth of body weight. The entire system weighs 142 g and fits in the space under the boot. Calibration between applied and measured force showed excellent agreement (R > 0.99), and a preliminary validation against a force plate showed good predictive ability overall (R ≥ 0.81 in vertical direction). The system overestimated the magnitude of the first and second impact peaks but detected their timing with high accuracy compared to the force plate.
Bending strength of delaminated aerospace composites.
Kinawy, Moustafa; Butler, Richard; Hunt, Giles W
2012-04-28
Buckling-driven delamination is considered among the most critical failure modes in composite laminates. This paper examines the propagation of delaminations in a beam under pure bending. A pre-developed analytical model to predict the critical buckling moment of a thin sub-laminate is extended to account for propagation prediction, using mixed-mode fracture analysis. Fractography analysis is performed to distinguish between mode I and mode II contributions to the final failure of specimens. Comparison between experimental results and analysis shows agreement to within 5 per cent in static propagation moment for two different materials. It is concluded that static fracture is almost entirely driven by mode II effects. This result was unexpected because it arises from a buckling mode that opens the delamination. For this reason, and because of the excellent repeatability of the experiments, the method of testing may be a promising means of establishing the critical value of mode II fracture toughness, G(IIC), of the material. Fatigue testing on similar samples showed that buckled delamination resulted in a fatigue threshold that was over 80 per cent lower than the static propagation moment. Such an outcome highlights the significance of predicting snap-buckling moment and subsequent propagation for design purposes.
Determining stability in connected speech in primary progressive aphasia and Alzheimer's disease.
Beales, Ashleigh; Whitworth, Anne; Cartwright, Jade; Panegyres, Peter K; Kane, Robert T
2018-03-08
Using connected speech to assess progressive language disorders is confounded by uncertainty around whether connected speech is stable over successive sampling, and therefore representative of an individual's performance, and whether some contexts and/or language behaviours show greater stability than others. A repeated measure, within groups, research design was used to investigate stability of a range of behaviours in the connected speech of six individuals with primary progressive aphasia and three individuals with Alzheimer's disease. Stability was evaluated, at a group and individual level, across three samples, collected over 3 weeks, involving everyday monologue, narrative and picture description, and analysed for lexical content, fluency and communicative informativeness and efficiency. Excellent and significant stability was found on the majority of measures, at a group and individual level, across all genres, with isolated measures (e.g. nouns use, communicative efficiency) showing good, but greater variability, within one of the three genres. Findings provide evidence of stability on measures of lexical content, fluency and communicative informativeness and efficiency. While preliminary evidence suggests that task selection is influential when considering stability of particular connected speech measures, replication over a larger sample is necessary to reproduce findings.
Detection of Biological Pathogens Using Multiple Wireless Magnetoelastic Biosensors
NASA Astrophysics Data System (ADS)
Shen, Wen
A number of recent, high-profile incidences of food-borne illness spreading through the food supply and the use of anthrax by terrorists after the September 11, 2001 attacks have demonstrated the need for new technologies that can rapidly detect the presence of biological pathogens. A bevy of biosensors show excellent detection sensitivity and specificity. However, false positive and false negative signals remain one of the primary reasons that many of these newly developed biosensors have not found application in the marketplace. The research described in this dissertation focuses on developing a free-standing magnetoelastic based bio-sensing system using a pulse method. This method allows fast detection, eliminates the bias magnetic field that is necessary in current methods, makes the system more simply and suitable for in-field detection. This system has two pairs of transformer coils, where a measurement sensor and a control sensor can be put in each pair of coils. The control sensor is used to compensate for environmental variables. The effect of pulse power on the performance of the magnetoelastic sensors in the pulse system is studied. The system is found to have excellent stability, good detection repeatability when used with multiple sensors. This research has investigated and demonstrated a multiple sensors approach. Because it will involve the simultaneous measurement of many sensors, it will significantly reduce problems encountered with false positive indications. The positioning and interference of sensors are investigated. By adding a multi-channel structure to the pulse detection system, the effect of sensor interference is minimized. The result of the repeatability test shows that the standard deviation when measuring three 1 mm magnetoelastic sensors is around 500 Hz, which is smaller than the minimum requirement for actual spores/bacteria detection. Magnetoelastic sensors immobilized with JRB7 phages and E2 phages have been used to specifically detect Bacillus anthracis spores and Salmonella typhimurium bacteria. The real-time monitoring of the detection of B. anthracis spores in a flowing system was performed using 2 mm sensors and 1 mm sensors. The detection of S. typhimurium in air has been performed using the pulse based system with both single and grouped sensors. Because grouped sensor detection involves the simultaneous measurement of many sensors, statistical evaluation shows that it can significantly reduce problems encountered with false positive indications. This method has been implemented in an investigation of a method that allows direct detection of S. typhimurium on cantaloupe surfaces. It has been demonstrated that multiple E2 phage based magnetoelastic sensors are able to detect Salmonella directly on fresh cantaloupe surfaces. Confirmation of the spore or bacteria binding to the sensor surfaces was achieved through SEM study of the sensor surfaces.
Ruschel, Caroline; Haupenthal, Alessandro; Jacomel, Gabriel Fernandes; Fontana, Heiliane de Brito; Santos, Daniela Pacheco dos; Scoz, Robson Dias; Roesler, Helio
2015-05-20
Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance. To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force. Validity (concurrent approach) and reliability (test and test-retest approach) study. University laboratory. 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study). Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study). In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles. The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.
Nomura, N; Saito, K; Ikeda, M; Yuasa, S; Pastore, M; Chabert, C; Kono, E; Sakai, A; Tanaka, H; Ikemoto, T; Takubo, T
2015-08-01
We evaluated the basic performance of Microsemi CRP, an unique automated hematology analyzer which can simultaneously measure CBC including 3-part WBC differential (3-Diff) and CRP using whole blood treated with EDTA-2K anticoagulant. We found that it produced generally the acceptable results for all parameters performed (repeatability, reproducibility, linearity, interference effect, carry over, and correlation) using control materials, fresh human whole bloods, and serum samples. CBC data examined using Microsemi CRP showed the good correlation with the previous model, Micros CRP200 (r ≧ 0.9), and also those obtained using the routine analyzer, ADVIA 2120i (r ≧ 0.989). Concerning the 3-Diff, both GRA (%) and LYM (%) showed the excellent correlation coefficient between Microsemi CRP and Micros CRP200 (r ≧ 0.992) as well as ADVIA 2120i (r ≧ 0.957). MON (%) showed good correlation between Microsemi CRP and Micros CRP200 (r = 0.959), but lower correlation between Microsemi CRP and ADVIA 2120 i (r = 0.471). CRP data showed the good correlation with HITACHI7600 (r ≧ 0.997) and Micros CRP200 (r ≧ 0.997). From these findings, we concluded that Microsemi CRP seemed the convenient laboratory analyzer in the setting of point of care testing (POCT) especially at NICU or primary care unit. © 2014 John Wiley & Sons Ltd.
Arnold, John B; Mackintosh, Shylie; Jones, Sara; Thewlis, Dominic
2013-06-01
Confidence in 3D multi-segment foot models has been limited by a lack of repeatability data, particularly in older populations that may display unique functional foot characteristics. This study aimed to determine the intra and inter-observer repeatability of stance phase kinematic data from a multi-segment foot model described by Leardini et al. [2] in people aged 50 years or older. Twenty healthy adults participated (mean age 65.4 years SD 8.4). A repeated measures study design was used with data collected from four testing sessions on two days from two observers. Intra (within-day and between-day) and inter-observer coefficient of multiple correlations revealed moderate to excellent similarity of stance phase joint range of motion (0.621-0.975). Relative to the joint range of motion (ROM), mean differences (MD) between sessions were highest for the within-day comparison for all planar ROM at the metatarsus-midfoot articulation (sagittal plane ROM 5.2° vs. 3.9°, MD 3.1°; coronal plane ROM 3.9 vs. 3.1°, MD 2.3°; transverse plane ROM 6.8° vs. 5.16°, MD 3.5°). Consequently, data from the metatarsus-midfoot articulation in the Istituto Ortopedico Rizzoli (IOR) foot model in adults aged over 50 years needs to be considered with respect to the findings of this study. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.
Repeatability of intravital capillaroscopic measurement of capillary density.
Lamah, M; Chaudhry, H; Mortimer, P S; Dormandy, J A
1996-01-01
The reliability of intravital capillaroscopy for determining capillary density (CD) of skin has been questioned because it depends upon the variability of the measuring process and subjective interpretation of data as well as the intrinsic heterogeneity of capillary spacing. The aim of this study was to assess the repeatability of a standardised method for measuring CD of the skin of the dorsum of foot. In each of 30 subjects (10 controls and 20 patients with peripheral vascular disease), the foot was systematically mapped by examining 20 sites on the dorsum of foot and 2 sites on each toe, using white light (native) videomicroscopy at 40 x magnification. Off-line analysis of videoprints was then undertaken to determine CD at each site, by counting capillaries within areas of acceptable photographic quality only, having first defined the criteria for counting capillaries. The mean values were then calculated and taken to represent the CD of the foot or toes. Repeatability of the measuring equipment was first assessed by noting the presence or absence of each corresponding capillary in 2 prints, taken at intervals of hours or days (in 10 subjects) or months (in 2 patients), of an identical area of skin which was marked by a microtattoo on the first occasion. On average, 95% of corresponding capillaries were identified in both prints (from controls and patients), thus implying little intrinsic temporal variation of capillary anatomy as well as excellent repeatability of the measuring equipment. Repeatability of data analysis was assessed by the same observer reading the same 20 prints in a blinded manner on three separate occasions (intraobserver repeatability), and 2 observers reading the same 24 prints (interobserver repeatability). The mean coefficient of intraobserver variation of CD estimate was 5.6% and the interobserver correlation coefficient was 0.94. Finally, overall repeatability of the method was assessed by repeating the procedure on a subsequent occasion (mean time interval of 5 days) in 10 subjects. The rate of agreement in mean CD between the two procedures [defined as 100- (difference between the two measurements/mean of the two measurements) x 100]% ranged from 86.4 to 97.1% (mean 93.5%). Thus using the above methodological technique, native capillaroscopy can be reliably used to determine CD of the dorsum of foot in comparing patient subgroups, as well as in longitudinal studies.
Algorithms and Complexity Results for Genome Mapping Problems.
Rajaraman, Ashok; Zanetti, Joao Paulo Pereira; Manuch, Jan; Chauve, Cedric
2017-01-01
Genome mapping algorithms aim at computing an ordering of a set of genomic markers based on local ordering information such as adjacencies and intervals of markers. In most genome mapping models, markers are assumed to occur uniquely in the resulting map. We introduce algorithmic questions that consider repeats, i.e., markers that can have several occurrences in the resulting map. We show that, provided with an upper bound on the copy number of repeated markers and with intervals that span full repeat copies, called repeat spanning intervals, the problem of deciding if a set of adjacencies and repeat spanning intervals admits a genome representation is tractable if the target genome can contain linear and/or circular chromosomal fragments. We also show that extracting a maximum cardinality or weight subset of repeat spanning intervals given a set of adjacencies that admits a genome realization is NP-hard but fixed-parameter tractable in the maximum copy number and the number of adjacent repeats, and tractable if intervals contain a single repeated marker.
Bright, Molly G; Murphy, Kevin
2013-12-01
Cerebrovascular reactivity (CVR) can be mapped using BOLD fMRI to provide a clinical insight into vascular health that can be used to diagnose cerebrovascular disease. Breath-holds are a readily accessible method for producing the required arterial CO2 increases but their implementation into clinical studies is limited by concerns that patients will demonstrate highly variable performance of breath-hold challenges. This study assesses the repeatability of CVR measurements despite poor task performance, to determine if and how robust results could be achieved with breath-holds in patients. Twelve healthy volunteers were scanned at 3 T. Six functional scans were acquired, each consisting of 6 breath-hold challenges (10, 15, or 20 s duration) interleaved with periods of paced breathing. These scans simulated the varying breath-hold consistency and ability levels that may occur in patient data. Uniform ramps, time-scaled ramps, and end-tidal CO2 data were used as regressors in a general linear model in order to measure CVR at the grey matter, regional, and voxelwise level. The intraclass correlation coefficient (ICC) quantified the repeatability of the CVR measurement for each breath-hold regressor type and scale of interest across the variable task performances. The ramp regressors did not fully account for variability in breath-hold performance and did not achieve acceptable repeatability (ICC<0.4) in several regions analysed. In contrast, the end-tidal CO2 regressors resulted in "excellent" repeatability (ICC=0.82) in the average grey matter data, and resulted in acceptable repeatability in all smaller regions tested (ICC>0.4). Further analysis of intra-subject CVR variability across the brain (ICCspatial and voxelwise correlation) supported the use of end-tidal CO2 data to extract robust whole-brain CVR maps, despite variability in breath-hold performance. We conclude that the incorporation of end-tidal CO2 monitoring into scanning enables robust, repeatable measurement of CVR that makes breath-hold challenges suitable for routine clinical practice. © 2013.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shukla-Dave, A; Lu, Y; Hatzoglou, V
2014-06-15
Purpose: To investigate the repeatability of reduced field-of-view diffusion-weighted imaging (rFOV DWI) in quantifying apparent diffusion coefficients (ADCs) for human thyroid glands in a clinical setting. Methods: Nine healthy human volunteers were enrolled and underwent 3T MRI exams. For each volunteer, 3 longitudinal exams (2 weeks apart) with 2 repetitive sessions within each exam, including rFOV and conventional full field-of-view (fFOV) DWI scans, were performed. In the acquired DWI images, a fixed-size region of interest (ROI; diameter=8mm) was placed on thyroid glands to calculate ADC. ADC was calculated using a monoexponential function with a noise correction scheme. The repeatability ofmore » ADC was assessed by using coefficient variation (CV) across sessions or exams, which was defined to be: r = 1-CV, 0 < r < 1, where CV=STD/m, STD is the standard deviation of ADC, and m is the average of ADC across sessions or exams. An experienced radiologist assessed and scored rFOV and fFOV DW images based on image characteristics (1, nondiagnostic; 2, poor; 3, satisfactory; 4, good; and 5, excellent).Analysis of variance (ANOVA) was performed to compare ADC values, CV of ADC, repeatability of ADC across sessions and exams, and radiologic scores between rFOV and fFOV DWI techniques. Results: There was no significant difference in ADC values across sessions and exams either in rFOV or fFOV DWI. The average CVs of both rFOV and fFOV DWI were less than 13%. The repeatability of ADC measurement between rFOV and fFOV DWI was not significantly different. The overall image quality was significantly higher with rFOV DWI than with fFOV DWI. Conclusion: This study suggested that ADCs from both rFOV and fFOV DWI were repeatable, but rFOV DWI had superior imaging quality for human thyroid glands in a clinical setting.« less
Isolation of human simple repeat loci by hybridization selection.
Armour, J A; Neumann, R; Gobert, S; Jeffreys, A J
1994-04-01
We have isolated short tandem repeat arrays from the human genome, using a rapid method involving filter hybridization to enrich for tri- or tetranucleotide tandem repeats. About 30% of clones from the enriched library cross-hybridize with probes containing trimeric or tetrameric tandem arrays, facilitating the rapid isolation of large numbers of clones. In an initial analysis of 54 clones, 46 different tandem arrays were identified. Analysis of these tandem repeat loci by PCR showed that 24 were polymorphic in length; substantially higher levels of polymorphism were displayed by the tetrameric repeat loci isolated than by the trimeric repeats. Primary mapping of these loci by linkage analysis showed that they derive from 17 chromosomes, including the X chromosome. We anticipate the use of this strategy for the efficient isolation of tandem repeats from other sources of genomic DNA, including DNA from flow-sorted chromosomes, and from other species.
A water-responsive shape memory ionomer with permanent shape reconfiguration ability
NASA Astrophysics Data System (ADS)
Bai, Yongkang; Zhang, Jiwen; Tian, Ran; Chen, Xin
2018-04-01
In this work, a water-responsive shape memory ionomer with high toughness was fabricated by cross-linking hyaluronic acid sodium (HAS) and polyvinyl alcohol (PVA) through coordination interactions. The strong Fe3+-carboxyl (from HAS) coordination interactions served as main physical cross-linking points for the performance of water-responsive shape memory, which associated with the flexibility of PVA chain producing excellent mechanical properties of this ionomer. The optimized ionomer was not only able to recover to its original shape within just 22 s by exposing to water, but exhibited high tensile strength up to 35.4 MPa and 4 times higher tractility than the ionomer without PVA. Moreover, the ionomers can be repeatedly programed to various new permanent shapes on demand due to the reversible physical interactions, which still performed complete and fast geometric recovery under stimuli even after 4 cycles of reprograming with 3 different shapes. The excellent shape memory and strong mechanical behaviors make our ionomers significant and promising smart materials for variety of applications.
The Design and Performance Evaluation of Hydroformed Tubular Torsion Beam Axle
NASA Astrophysics Data System (ADS)
Kim, Jaehyun; Oh, Jinho; Choi, Hanho
2010-06-01
Suspensions for vehicles are structural devices used for suspending a vehicle body and absorbing shocks from the road. Thus, the suspensions must be designed such that they can attenuate shocks from a road and make passengers feel comfortable despite the shocks, and improve steering stability, determined by the ground contact force of tires during running of vehicles. Another important factor to be considered while designing suspensions is that the suspensions must maintain desired stiffness and desired durability despite the repeated application of shocks from roads thereto. The present relates, in general, to a tubular torsion beam for rear suspensions of vehicles and a manufacturing method thereof and, more particularly, to the provision of tubular torsion beams having excellent roll stiffness and excellent roll strength, produced through hydroforming. The hydroforming technology has a lot of benefit which is shape accuracy, good durability caused by compressive pressure, and good forming quality. In this study, the performance evaluation of the hydroformed tubular torsion beam axle is evaluated.
Yang, Qu; Zhou, Ziyao; Wang, Liqian; Zhang, Hongjia; Cheng, Yuxin; Hu, Zhongqiang; Peng, Bin; Liu, Ming
2018-05-01
To meet the demand of developing compatible and energy-efficient flexible spintronics, voltage manipulation of magnetism on soft substrates is in demand. Here, a voltage tunable flexible field-effect transistor structure by ionic gel (IG) gating in perpendicular synthetic anti-ferromagnetic nanostructure is demonstrated. As a result, the interlayer Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction can be tuned electrically at room temperature. With a circuit gating voltage, anti-ferromagnetic (AFM) ordering is enhanced or converted into an AFM-ferromagnetic (FM) intermediate state, accompanying with the dynamic domain switching. This IG gating process can be repeated stably at different curvatures, confirming an excellent mechanical property. The IG-induced modification of interlayer exchange coupling is related to the change of Fermi level aroused by the disturbance of itinerant electrons. The voltage modulation of RKKY interaction with excellent flexibility proposes an application potential for wearable spintronic devices with energy efficiency and ultralow operation voltage. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A study on the trinucleotide repeat associated with Huntington`s disease in the Chinese
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bing-wen Soong; Jih-tsuu Wang
1994-09-01
Analysis of the polymorphic (CAG)n repeat in the hungingtin gene in the chinese confirmed the presence of an expanded repeat on all Huntington`s disease chromosomes. Measurement of the specific CAG repeat sequence in 34 HD chromosomes from 15 unrelated families and 190 control chromosomes from the Chinese population showed a range from 9 to 29 repeats in normal subjects and 40 to 58 in affected subjects. The size distributions of normal and affected alleles did not overlap. A clear correlation bewteen early onset of symptoms and very high repeat number was seen, but the spread of the age-at-onset in themore » major repeat range producing characteristic HD it too wide to be of diagnostic value. There was also variability in the transmitted repeat size for both sexes in the HD size range. Maternal HD alleles showed a moderate instability with a preponderance of size decrease, while paternal HD alleles had a tendency to increase in repeat size on transmission, the degree of which appeared proportional to the initial size.« less
Environmental stress induces trinucleotide repeat mutagenesis in human cells
Chatterjee, Nimrat; Lin, Yunfu; Santillan, Beatriz A.; Yotnda, Patricia; Wilson, John H.
2015-01-01
The dynamic mutability of microsatellite repeats is implicated in the modification of gene function and disease phenotype. Studies of the enhanced instability of long trinucleotide repeats (TNRs)—the cause of multiple human diseases—have revealed a remarkable complexity of mutagenic mechanisms. Here, we show that cold, heat, hypoxic, and oxidative stresses induce mutagenesis of a long CAG repeat tract in human cells. We show that stress-response factors mediate the stress-induced mutagenesis (SIM) of CAG repeats. We show further that SIM of CAG repeats does not involve mismatch repair, nucleotide excision repair, or transcription, processes that are known to promote TNR mutagenesis in other pathways of instability. Instead, we find that these stresses stimulate DNA rereplication, increasing the proportion of cells with >4 C-value (C) DNA content. Knockdown of the replication origin-licensing factor CDT1 eliminates both stress-induced rereplication and CAG repeat mutagenesis. In addition, direct induction of rereplication in the absence of stress also increases the proportion of cells with >4C DNA content and promotes repeat mutagenesis. Thus, environmental stress triggers a unique pathway for TNR mutagenesis that likely is mediated by DNA rereplication. This pathway may impact normal cells as they encounter stresses in their environment or during development or abnormal cells as they evolve metastatic potential. PMID:25775519
Environmental stress induces trinucleotide repeat mutagenesis in human cells.
Chatterjee, Nimrat; Lin, Yunfu; Santillan, Beatriz A; Yotnda, Patricia; Wilson, John H
2015-03-24
The dynamic mutability of microsatellite repeats is implicated in the modification of gene function and disease phenotype. Studies of the enhanced instability of long trinucleotide repeats (TNRs)-the cause of multiple human diseases-have revealed a remarkable complexity of mutagenic mechanisms. Here, we show that cold, heat, hypoxic, and oxidative stresses induce mutagenesis of a long CAG repeat tract in human cells. We show that stress-response factors mediate the stress-induced mutagenesis (SIM) of CAG repeats. We show further that SIM of CAG repeats does not involve mismatch repair, nucleotide excision repair, or transcription, processes that are known to promote TNR mutagenesis in other pathways of instability. Instead, we find that these stresses stimulate DNA rereplication, increasing the proportion of cells with >4 C-value (C) DNA content. Knockdown of the replication origin-licensing factor CDT1 eliminates both stress-induced rereplication and CAG repeat mutagenesis. In addition, direct induction of rereplication in the absence of stress also increases the proportion of cells with >4C DNA content and promotes repeat mutagenesis. Thus, environmental stress triggers a unique pathway for TNR mutagenesis that likely is mediated by DNA rereplication. This pathway may impact normal cells as they encounter stresses in their environment or during development or abnormal cells as they evolve metastatic potential.
Gupta, Rashmi; Mirdha, Bijay Ranjan; Guleria, Randeep; Kumar, Lalit; Luthra, Kalpana; Agarwal, Sanjay Kumar; Sreenivas, Vishnubhatla
2013-01-01
Pneumocystis jirovecii is an opportunistic pathogen that causes severe pneumonia in immunocompromised patients. To study the genetic diversity of P. jirovecii in India the upstream conserved sequence (UCS) region of Pneumocystis genome was amplified, sequenced and genotyped from a set of respiratory specimens obtained from 50 patients with a positive result for nested mitochondrial large subunit ribosomal RNA (mtLSU rRNA) PCR during the years 2005-2008. Of these 50 cases, 45 showed a positive PCR for UCS region. Variations in the tandem repeats in UCS region were characterized by sequencing all the positive cases. Of the 45 cases, one case showed five repeats, 11 cases showed four repeats, 29 cases showed three repeats and four cases showed two repeats. By running amplified DNA from all these cases on a high-resolution gel, mixed infection was observed in 12 cases (26.7%, 12/45). Forty three of 45 cases included in this study had previously been typed at mtLSU rRNA and internal transcribed spacer (ITS) region by our group. In the present study, the genotypes at those two regions were combined with UCS repeat patterns to construct allelic profiles of 43 cases. A total of 36 allelic profiles were observed in 43 isolates indicating high genetic variability. A statistically significant association was observed between mtLSU rRNA genotype 1, ITS type Ea and UCS repeat pattern 4. Copyright © 2012 Elsevier B.V. All rights reserved.
DNA-binding proteins from marine bacteria expand the known sequence diversity of TALE-like repeats
de Lange, Orlando; Wolf, Christina; Thiel, Philipp; Krüger, Jens; Kleusch, Christian; Kohlbacher, Oliver; Lahaye, Thomas
2015-01-01
Transcription Activator-Like Effectors (TALEs) of Xanthomonas bacteria are programmable DNA binding proteins with unprecedented target specificity. Comparative studies into TALE repeat structure and function are hindered by the limited sequence variation among TALE repeats. More sequence-diverse TALE-like proteins are known from Ralstonia solanacearum (RipTALs) and Burkholderia rhizoxinica (Bats), but RipTAL and Bat repeats are conserved with those of TALEs around the DNA-binding residue. We study two novel marine-organism TALE-like proteins (MOrTL1 and MOrTL2), the first to date of non-terrestrial origin. We have assessed their DNA-binding properties and modelled repeat structures. We found that repeats from these proteins mediate sequence specific DNA binding conforming to the TALE code, despite low sequence similarity to TALE repeats, and with novel residues around the BSR. However, MOrTL1 repeats show greater sequence discriminating power than MOrTL2 repeats. Sequence alignments show that there are only three residues conserved between repeats of all TALE-like proteins including the two new additions. This conserved motif could prove useful as an identifier for future TALE-likes. Additionally, comparing MOrTL repeats with those of other TALE-likes suggests a common evolutionary origin for the TALEs, RipTALs and Bats. PMID:26481363
Koon, Alex C.; Chan, Ho Yin Edwin
2017-01-01
For nearly a century, the fruit fly, Drosophila melanogaster, has proven to be a valuable tool in our understanding of fundamental biological processes, and has empowered our discoveries, particularly in the field of neuroscience. In recent years, Drosophila has emerged as a model organism for human neurodegenerative and neuromuscular disorders. In this review, we highlight a number of recent studies that utilized the Drosophila model to study repeat-expansion associated diseases (READs), such as polyglutamine diseases, fragile X-associated tremor/ataxia syndrome (FXTAS), myotonic dystrophy type 1 (DM1) and type 2 (DM2), and C9ORF72-associated amyotrophic lateral sclerosis/frontotemporal dementia (C9-ALS/FTD). Discoveries regarding the possible mechanisms of RNA toxicity will be focused here. These studies demonstrate Drosophila as an excellent in vivo model system that can reveal novel mechanistic insights into human disorders, providing the foundation for translational research and therapeutic development. PMID:28377694
Drira, Ines; Hadrich, Ines; Neji, Sourour; Mahfouth, Nedia; Trabelsi, Houaida; Sellami, Hayet; Makni, Fattouma
2014-01-01
Trichophyton interdigitale is the second most frequent cause of superficial fungal infections of various parts of the human body. Studying the population structure and genotype differentiation of T. interdigitale strains may lead to significant improvements in clinical practice. The present study aimed to develop and select suitable variable-number tandem-repeat (VNTR) markers for 92 clinical strains of T. interdigitale. On the basis of an analysis of four VNTR markers, four to eight distinct alleles were detected for each marker. The marker with the highest discriminatory power had eight alleles and a D value of 0.802. The combination of all four markers yielded a D value of 0.969 with 29 distinct multilocus genotypes. VNTR typing revealed the genetic diversity of the strains, identifying three populations according to their colonization sites. A correlation between phenotypic characteristics and multilocus genotypes was observed. Seven patients harbored T. interdigitale strains with different genotypes. Typing of clinical T. interdigitale samples by VNTR markers displayed excellent discriminatory power and 100% reproducibility. PMID:24989614
Namdari, Mehrdad; Eatemadi, Ali; Soleimaninejad, Maryam; Hammed, Aiyelabegan T
2017-03-01
Herbal medicines have been routinely employed all over the world dated back from the ancient time and have been identified by patients and physicians for their excellent therapeutic value as they have lower adverse effects when compared with the modern medicines. Phytotherapeutics requires a scientific technique to deliver the active herbal extract in a controlled manner to avoid repeated administration and increase patient compliance. This can be reached by fabricating a novel drug delivery systems (NDDS) for herbal components. NDDSs does not only decrease the repeated dose to overcome ineffectiveness, but also help to increase potency by decreasing toxicity and elevating drug bioavailability. Nano-sized DDS of herbal drugs have a potential application for improving the activity and countering the problems related to herbal medicines. Hence, application of nanocarriers as an NDDS in the traditional herbal medicine system is important to treat more chronic diseases like infectious endocarditis. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Investigation of a Quadruplex-Forming Repeat Sequence Highly Enriched in Xanthomonas and Nostoc sp.
Rehm, Charlotte; Wurmthaler, Lena A; Li, Yuanhao; Frickey, Tancred; Hartig, Jörg S
2015-01-01
In prokaryotes simple sequence repeats (SSRs) with unit sizes of 1-5 nucleotides (nt) are causative for phase and antigenic variation. Although an increased abundance of heptameric repeats was noticed in bacteria, reports about SSRs of 6-9 nt are rare. In particular G-rich repeat sequences with the propensity to fold into G-quadruplex (G4) structures have received little attention. In silico analysis of prokaryotic genomes show putative G4 forming sequences to be abundant. This report focuses on a surprisingly enriched G-rich repeat of the type GGGNATC in Xanthomonas and cyanobacteria such as Nostoc. We studied in detail the genomes of Xanthomonas campestris pv. campestris ATCC 33913 (Xcc), Xanthomonas axonopodis pv. citri str. 306 (Xac), and Nostoc sp. strain PCC7120 (Ana). In all three organisms repeats are spread all over the genome with an over-representation in non-coding regions. Extensive variation of the number of repetitive units was observed with repeat numbers ranging from two up to 26 units. However a clear preference for four units was detected. The strong bias for four units coincides with the requirement of four consecutive G-tracts for G4 formation. Evidence for G4 formation of the consensus repeat sequences was found in biophysical studies utilizing CD spectroscopy. The G-rich repeats are preferably located between aligned open reading frames (ORFs) and are under-represented in coding regions or between divergent ORFs. The G-rich repeats are preferentially located within a distance of 50 bp upstream of an ORF on the anti-sense strand or within 50 bp from the stop codon on the sense strand. Analysis of whole transcriptome sequence data showed that the majority of repeat sequences are transcribed. The genetic loci in the vicinity of repeat regions show increased genomic stability. In conclusion, we introduce and characterize a special class of highly abundant and wide-spread quadruplex-forming repeat sequences in bacteria.
Investigation of a Quadruplex-Forming Repeat Sequence Highly Enriched in Xanthomonas and Nostoc sp.
Rehm, Charlotte; Wurmthaler, Lena A.; Li, Yuanhao; Frickey, Tancred; Hartig, Jörg S.
2015-01-01
In prokaryotes simple sequence repeats (SSRs) with unit sizes of 1–5 nucleotides (nt) are causative for phase and antigenic variation. Although an increased abundance of heptameric repeats was noticed in bacteria, reports about SSRs of 6–9 nt are rare. In particular G-rich repeat sequences with the propensity to fold into G-quadruplex (G4) structures have received little attention. In silico analysis of prokaryotic genomes show putative G4 forming sequences to be abundant. This report focuses on a surprisingly enriched G-rich repeat of the type GGGNATC in Xanthomonas and cyanobacteria such as Nostoc. We studied in detail the genomes of Xanthomonas campestris pv. campestris ATCC 33913 (Xcc), Xanthomonas axonopodis pv. citri str. 306 (Xac), and Nostoc sp. strain PCC7120 (Ana). In all three organisms repeats are spread all over the genome with an over-representation in non-coding regions. Extensive variation of the number of repetitive units was observed with repeat numbers ranging from two up to 26 units. However a clear preference for four units was detected. The strong bias for four units coincides with the requirement of four consecutive G-tracts for G4 formation. Evidence for G4 formation of the consensus repeat sequences was found in biophysical studies utilizing CD spectroscopy. The G-rich repeats are preferably located between aligned open reading frames (ORFs) and are under-represented in coding regions or between divergent ORFs. The G-rich repeats are preferentially located within a distance of 50 bp upstream of an ORF on the anti-sense strand or within 50 bp from the stop codon on the sense strand. Analysis of whole transcriptome sequence data showed that the majority of repeat sequences are transcribed. The genetic loci in the vicinity of repeat regions show increased genomic stability. In conclusion, we introduce and characterize a special class of highly abundant and wide-spread quadruplex-forming repeat sequences in bacteria. PMID:26695179
Almeida, Gustavo J; Irrgang, James J; Fitzgerald, G Kelley; Jakicic, John M; Piva, Sara R
2016-06-01
Few instruments that measure physical activity (PA) can accurately quantify PA performed at light and moderate intensities, which is particularly relevant in older adults. The evidence of their reliability in free-living conditions is limited. The study objectives were: (1) to determine the test-retest reliability of the Actigraph (ACT), SenseWear Armband (SWA), and Community Healthy Activities Model Program for Seniors (CHAMPS) questionnaire in assessing free-living PA at light and moderate intensities in people after total knee arthroplasty; (2) to compare the reliability of the 3 instruments relative to each other; and (3) to determine the reliability of commonly used monitoring time frames (24 hours, waking hours, and 10 hours from awakening). A one-group, repeated-measures design was used. Participants wore the activity monitors for 2 weeks, and the CHAMPS questionnaire was completed at the end of each week. Test-retest reliability was determined by using the intraclass correlation coefficient (ICC [2,k]) to compare PA measures from one week with those from the other week. Data from 28 participants who reported similar PA during the 2 weeks were included in the analysis. The mean age of these participants was 69 years (SD=8), and 75% of them were women. Reliability ranged from moderate to excellent for the ACT (ICC=.75-.86) and was excellent for the SWA (ICC=.93-.95) and the CHAMPS questionnaire (ICC=.86-.92). The 95% confidence intervals (95% CI) of the ICCs from the SWA were the only ones within the excellent reliability range (.85-.98). The CHAMPS questionnaire showed systematic bias, with less PA being reported in week 2. The reliability of PA measures in the waking-hour time frame was comparable to that in the 24-hour time frame and reflected most PA performed during this period. Reliability may be lower for time intervals longer than 1 week. All PA measures showed good reliability. The reliability of the ACT was lower than those of the SWA and the CHAMPS questionnaire. The SWA provided more precise reliability estimates. Wearing PA monitors during waking hours provided sufficiently reliable measures and can reduce the burden on people wearing them. © 2016 American Physical Therapy Association.
NASA Astrophysics Data System (ADS)
Zha, Daosong; Fu, Yongsheng; Zhang, Lili; Zhu, Junwu; Wang, Xin
2018-02-01
Nickel cobalt sulfides (NiCo-S) are promising electrode materials for high-performance supercapacitors but normally show poor rate capability and unsatisfactory long-term endurance. To overcome these disadvantages, a properly constructed electrode architecture with abundant electron transport channels, excellent electronic conductivity and robust structural stability is required. Herein, considering that in situ transformation can mostly retain the specific structural advantages of the precursors, a two-step strategy is purposefully developed to construct a binder-free electrode composed of interconnected NiCo-S nanosheets on Ni foam (NiCo-S/NF), in which NiCo-S/NF is synthesized via the in situ sulfuration of networked acetate anion-intercalated nickel cobalt layered double hydroxide nanosheets loaded on Ni foam (A-NiCo-LDH/NF). Noticeably, the optimized Ni1Co1-S/NF exhibits an ultrahigh specific capacitance of 2553.9 F g-1 at 0.5 A g-1, excellent rate capability (1898.1 F g-1 at 50 A g-1) and superior cycling stability (nearly 90% capacitance retention after 10,000 cycles). Furthermore, the assembled asymmetric supercapacitor based on Ni1Co1-S/NF demonstrates a high energy density of 58.1 Wh kg-1 at a power density of 796 W kg-1 and impressive long-term durability even after a repeated charge/discharge process as long as 70,000 cycles (∼92% capacitance retention). The attractive properties endow the Ni1Co1-S/NF electrode with significant potential for high-performance energy storage devices.
Scaglioni-Solano, Pietro; Aragón-Vargas, Luis F
2014-06-01
Standing balance is an important motor task. Postural instability associated with age typically arises from deterioration of peripheral sensory systems. The modified Clinical Test of Sensory Integration for Balance and the Tandem test have been used to screen for balance. Timed tests present some limitations, whereas quantification of the motions of the center of pressure (CoP) with portable and inexpensive equipment may help to improve the sensitivity of these tests and give the possibility of widespread use. This study determines the validity and reliability of the Wii Balance Board (Wii BB) to quantify CoP motions during the mentioned tests. Thirty-seven older adults completed three repetitions of five balance conditions: eyes open, eyes closed, eyes open on a compliant surface, eyes closed on a compliant surface, and tandem stance, all performed on a force plate and a Wii BB simultaneously. Twenty participants repeated the trials for reliability purposes. CoP displacement was the main outcome measure. Regression analysis indicated that the Wii BB has excellent concurrent validity, and Bland-Altman plots showed good agreement between devices with small mean differences and no relationship between the difference and the mean. Intraclass correlation coefficients (ICCs) indicated modest-to-excellent test-retest reliability (ICC=0.64-0.85). Standard error of measurement and minimal detectable change were similar for both devices, except the 'eyes closed' condition, with greater standard error of measurement for the Wii BB. In conclusion, the Wii BB is shown to be a valid and reliable method to quantify CoP displacement in older adults.
Ultrahigh broadband photoresponse of SnO2 nanoparticle thin film/SiO2/p-Si heterojunction.
Ling, Cuicui; Guo, Tianchao; Lu, Wenbo; Xiong, Ya; Zhu, Lei; Xue, Qingzhong
2017-06-29
The SnO 2 /Si heterojunction possesses a large band offset and it is easy to control the transportation of carriers in the SnO 2 /Si heterojunction to realize high-response broadband detection. Therefore, we investigated the potential of the SnO 2 nanoparticle thin film/SiO 2 /p-Si heterojunction for photodetectors. It is demonstrated that this heterojunction shows a stable, repeatable and broadband photoresponse from 365 nm to 980 nm. Meanwhile, the responsivity of the device approaches a high value in the range of 0.285-0.355 A W -1 with the outstanding detectivity of ∼2.66 × 10 12 cm H 1/2 W -1 and excellent sensitivity of ∼1.8 × 10 6 cm 2 W -1 , and its response and recovery times are extremely short (<0.1 s). This performance makes the device stand out among previously reported oxide or oxide/Si based photodetectors. In fact, the photosensitivity and detectivity of this heterojunction are an order of magnitude higher than that of 2D material based heterojunctions such as (Bi 2 Te 3 )/Si and MoS 2 /graphene (photosensitivity of 7.5 × 10 5 cm 2 W -1 and detectivity of ∼2.5 × 10 11 cm H 1/2 W -1 ). The excellent device performance is attributed to the large Fermi energy difference between the SnO 2 nanoparticle thin film and Si, SnO 2 nanostructure, oxygen vacancy defects and thin SiO 2 layer. Consequently, practical highly-responsive broadband PDs may be actualized in the future.
Du, Yucheng; Zhang, Shihao; Wang, Jinshu; Wu, Junshu; Dai, Hongxing
2018-04-01
Niobium oxide nanowire-deposited carbon fiber (CF) samples were prepared using a hydrothermal method with amorphous Nb 2 O 5 ·nH 2 O as precursor. The physical properties of the samples were characterized by means of numerous techniques, including X-ray diffraction (XRD), energy-dispersive spectroscopy (EDS), scanning electron microscopy (SEM), transmission electron microscopy (TEM), selected-area electron diffraction (SAED), UV-visible spectroscopy (UV-vis), N 2 adsorption-desorption, Fourier transform infrared spectroscopy (FT-IR), and X-ray photoelectron spectroscopy. The efficiency for the removal of Cr(VI) was determined. Parameters such as pH value and initial Cr(VI) concentration could influence the Cr(VI) removal efficiency or adsorption capacity of the Nb 2 O 5 /carbon fiber sample obtained after hydrothermal treatment at 160°C for 14hr. The maximal Cr(VI) adsorption capacity of the Nb 2 O 5 nanowire/CF sample was 115mg/g. This Nb 2 O 5 /CF sample also showed excellent photocatalytic activity and stability for the reduction of Cr(VI) under UV-light irradiation: the Cr(VI) removal efficiency reached 99.9% after UV-light irradiation for 1hr and there was no significant decrease in photocatalytic performance after the use of the sample for 10 repeated cycles. Such excellent Cr(VI) adsorption capacity and photocatalytic performance was related to its high surface area, abundant surface hydroxyl groups, and good UV-light absorption ability. Copyright © 2017. Published by Elsevier B.V.
High-Intensity Small-Sided Games versus Repeated Sprint Training in Junior Soccer Players.
Eniseler, Niyazi; Şahan, Çağatay; Özcan, Ilker; Dinler, Kıvanç
2017-12-01
The aim of this study was to compare the effects of high-intensity small-sided games training (SSGT) versus repeated-sprint training (RST) on repeated-sprint ability (RSA), soccer specific endurance performance and short passing ability among junior soccer players. The junior soccer players were recruited from of a professional team (age 16.9 ± 1.1 years). The tests included the repeated-shuttle-sprint ability test (RSSAT), Yo-Yo Intermittent Recovery Test level 1 (Yo-Yo IR1) and Loughborough Soccer Passing Test (LSPT). Nineteen participants were randomly assigned to either the small-sided games training (SSGTG) (n = 10) or repeated-sprint training group (RSTG) (n = 9). Small-sided games or repeated-sprint training were added to the regular training sessions for two days of the regular practice week. The Wilcoxon signed-rank and Mann-Whitney U tests were used to examine differences in groups and training effects. A time x training group effect was found in the improvement of short-passing ability for the smallsided games training group which showed significantly better scores than the repeated-sprint training group (p ≤ 0.05). Both groups showed similar improvements in RSAdecrement (p < 0.05). Only the repeated-sprint training group improved in the Yo-Yo IR1 (p < 0.05). This study clearly shows that high-intensity small-sided games training can be used as an effective training mode to enhance both repeated sprint ability and short-passing ability.
High-Intensity Small-Sided Games versus Repeated Sprint Training in Junior Soccer Players
Şahan, Çağatay; Özcan, Ilker; Dinler, Kıvanç
2017-01-01
Abstract The aim of this study was to compare the effects of high-intensity small-sided games training (SSGT) versus repeated-sprint training (RST) on repeated-sprint ability (RSA), soccer specific endurance performance and short passing ability among junior soccer players. The junior soccer players were recruited from of a professional team (age 16.9 ± 1.1 years). The tests included the repeated-shuttle-sprint ability test (RSSAT), Yo-Yo Intermittent Recovery Test level 1 (Yo-Yo IR1) and Loughborough Soccer Passing Test (LSPT). Nineteen participants were randomly assigned to either the small-sided games training (SSGTG) (n = 10) or repeated-sprint training group (RSTG) (n = 9). Small-sided games or repeated-sprint training were added to the regular training sessions for two days of the regular practice week. The Wilcoxon signed-rank and Mann-Whitney U tests were used to examine differences in groups and training effects. A time x training group effect was found in the improvement of short-passing ability for the smallsided games training group which showed significantly better scores than the repeated-sprint training group (p ≤ 0.05). Both groups showed similar improvements in RSAdecrement (p < 0.05). Only the repeated-sprint training group improved in the Yo-Yo IR1 (p < 0.05). This study clearly shows that high-intensity small-sided games training can be used as an effective training mode to enhance both repeated sprint ability and short-passing ability. PMID:29339990
Witonski, D. ; Stefanova, R.; Ranganathan, A.; Schutze, G. E.; Eisenach, K. D.; Cave, M. D.
2006-01-01
The genome of Salmonella enterica subsp. enterica serovar Typhimurium strain LT2 was analyzed for direct repeats, and 54 sequences containing variable-number tandem repeat loci were identified. Ten primer pairs that anneal upstream and downstream of each selected locus were designed and used to amplify PCR targets in isolates of S. enterica serovars Typhimurium and Newport. Four of the 10 loci did not show polymorphism in the length of products. Six loci were selected for analysis. Isolates of S. enterica serovars Typhimurium and Newport that were related to specific outbreaks and showed identical pulsed-field gel electrophoresis patterns were indistinguishable by the length of the six variable-number tandem repeats. Isolates that differed in their pulsed-field gel electrophoresis patterns showed polymorphism in variable-number tandem repeat profiles. Length of the products was confirmed by DNA sequence analysis. Only 2 of the 10 loci contained exact integers of the direct repeat. Eight loci contained partial copies. The partial copies were maintained at the ends of the variable-number tandem repeat loci in all isolates. In spite of having partial copies that were maintained in all isolates, the number of direct repeats at a locus was polymorphic. Six variable-number tandem repeat loci were useful in distinguishing isolates of S. enterica serovars Typhimurium and Newport that had different pulsed-field gel electrophoresis patterns and in identifying outbreak-associated cases that shared a common pulsed-field gel pattern. PMID:16943354
NASA Astrophysics Data System (ADS)
Gasmi, Taieb
2018-04-01
An extra-cavity CO2-TEA laser pulse clipper for high spatial resolution atmospheric monitoring is presented. The clipper uses pulsed high voltageto facilitate the breakdown of the gas within the clipper cell. Complete extinction of the nitrogen tail, that degrades the range resolution of LIDARS, is obtained at pressures from 375 up to 1500 Torr for nitrogen and argon gases whereas an attenuation coefficient of almost 102 is achieved for helium. Excellent energy stability and pulse width repeatability were achieved using high voltage pre-ionized gas technique.
A compact plasma pre-ionized TEA-CO2 laser pulse clipper for material processing
NASA Astrophysics Data System (ADS)
Gasmi, Taieb
2017-08-01
An extra-laser cavity CO2-TEA laser pulse clipper using gas breakdown techniques for high spatial resolution material processing and shallow material engraving and drilling processes is presented. Complete extinction of the nitrogen tail, that extends the pulse width, is obtained at pressures from 375 up to 1500 torr for nitrogen and argon gases. Excellent energy stability and pulse repeatability were further enhanced using high voltage assisted preionized plasma gas technique. Experimental data illustrates the direct correlation between laser pulse width and depth of engraving in aluminum and alumina materials.
Advances with holographic DESA emulsions
NASA Astrophysics Data System (ADS)
Dünkel, Lothar; Eichler, Jürgen; Schneeweiss, Claudia; Ackermann, Gerhard
2006-02-01
DESA emulsions represent layer systems based on ultra-fine grained silver halide (AgX) technology. The new layers have an excellent performance for holographic application. The technology has been presented repeatedly in recent years, including the emulsion characterization and topics of chemical and spectral sensitization. The paper gives a survey of actual results referring to panchromatic sensitization and other improvements like the application of silver halide sensitized gelatine (SHSG) procedure. These results are embedded into intensive collaborations with small and medium enterprises (SME's) to commercialize DESA layers. Predominant goals are innovative products with holographic components and layers providing as well as cost effectiveness and high quality.
NASA Astrophysics Data System (ADS)
Sukmasari, S.; Lestari, W.; Ko, B. B.; Noh, Z.; Asmail, N.; Yaacob, N.
2017-08-01
Newly introduced ICDAS II as a visual method, laser fluorescence as another technique that have ability to quantify early mineral loss of tooth structure and intra oral radiograph, are methods can be used in the clinic. To provide standardization for comprehensive caries management at an early stage, all methods supposed to be tested between users. The objective of this research is to evaluate the repeatability of each system. It is a comparative cross sectional study using 100 extracted permanent teeth without obvious cavitation (premolar & molar) that were collected and stored in thymol solution. The teeth were embedded on the wax block and labeled with numbers. All 5 surfaces were examined by 5 examiners using visual (ICDAS II), laser fluorescence (LF) and radiographic examination. The data were then analyzed to measure intra and inter examiner repeatability using Cronbach’s alpha and inter-item correlation matrix. Intra-examiner repeatability for all examiners was >0.7. Chronbach’s a value for inter-examiner repeatability for ICDAS II was >0.8 on 3 surfaces except on buccal and lingual. LF exhibit repeatability of >0.8 on all surfaces. Radiograph shows a low value of inter examiner repeatability (<0.7). Lecturer examiners showed the highest agreement followed by undergraduate students for inter-item correlation while the 2nd and 3rd reading of LF displays the best agreement. ICDAS II score favors more non-invasive treatment compared to LF. ICDAS II showed good repeatability except on buccal and lingual surfaces. In line with some of the previous study, ICDAS II is applicable for caries detection in daily clinical basis. Laser fluorescence exhibits the highest repeatability while the radiograph showed weak inter-examiner repeatability. Treatment decisions of ICDAS II propose more preventive treatment for early caries lesions compared to laser fluorescence.
Dalby, Andrew R.
2009-01-01
Background Microsatellites have been used extensively in the field of comparative genomics. By studying microsatellites in coding regions we have a simple model of how genotypic changes undergo selection as they are directly expressed in the phenotype as altered proteins. The simplest of these tandem repeats in coding regions are the tri-nucleotide repeats which produce a repeat of a single amino acid when translated into proteins. Tri-nucleotide repeats are often disease associated, and are also known to be unstable to both expansion and contraction. This makes them sensitive markers for studying proteome evolution, in closely related species. Results The evolutionary history of the family of malarial causing parasites Plasmodia is complex because of the life-cycle of the organism, where it interacts with a number of different hosts and goes through a series of tissue specific stages. This study shows that the divergence between the primate and rodent malarial parasites has resulted in a lineage specific change in the simple amino acid repeat distribution that is correlated to A–T content. The paper also shows that this altered use of amino acids in SAARs is consistent with the repeat distributions being under selective pressure. Conclusions The study shows that simple amino acid repeat distributions can be used to group related species and to examine their phylogenetic relationships. This study also shows that an outgroup species with a similar A–T content can be distinguished based only on the amino acid usage in repeats, and suggest that this might be a useful feature for proteome clustering. The lineage specific use of amino acids in repeat regions suggests that comparative studies of SAAR distributions between proteomes gives an insight into the mechanisms of expansion and the selective pressures acting on the organism. PMID:19597555
How does the human impact of footpaths affect flora biodiversity in the rainforest?
NASA Astrophysics Data System (ADS)
Chan, J. H. F.
2017-12-01
Tioman Island is the largest Island in the Pahang region in Malaysia, known for its biodiverse reefs and dense rainforests, making it a popular tourist site. Over the course of two weeks, I was able to collect data on how the heavy development of Tioman Island's tourist industry was affecting the biodiversity of the region, specifically the implementation of infrastructure like footpaths. Tioman was an excellent setting for my research as it provided both primary and secondary rainforest with varying amounts of developments, allowing me to draw parallels between the data of the two distinct footpaths. To measure biodiversity against the prevalence of footpaths in forests, I set up 10 adjacent two by one meter quadrats perpendicular to the path, the first being on the path, and counted the quantities of different species within each quadrat. This process was repeated three times with five meter spacings between the various transects to better represent biodiversity in the region. Those three trials were then repeated at a site of contrasting human impact to come up with 60 quadrats' worth of data. Individually, each quadrat's biodiversity was then quantified using the Simpson's Diversity Index, which was then given a Spearman's Rank Correlation Coefficient before being compared with one another. The results of my research showed a general increase in biodiversity levels the further away it was from the path, until a certain point where it dropped and displayed a steady state, which did not fulfill the linear trend I was expecting in my hypothesis.
Delextrat, A; Bateman, J; Esser, P; Targen, N; Dawes, H
2016-08-01
To assess the feasibility of Zumba Gold(®) in people with PD, and to investigate the effects of dance styles and number of sessions on activity levels and physiological load. Repeated measure uncontrolled (single group) feasibility study. Eleven participants (age: 64.0±8.1years) with mild-to-moderate idiopathic PD (Hoehn & Yahr stage<3.0) took part in a screening session, followed by six Zumba Gold(®) workouts each separated by one week, and a follow-up interview six months later. The main feasibility parameters measured were retention, compliance, and adverse events. Furthermore, during each Zumba Gold(®) session, physical activity levels were measured using tri-axial accelerometers, while physiological load was assessed by average heart rate (HRmean). A two-way ANOVA with repeated measures assessed the effects of dance styles and session number on activity level and HR. 73% retention and 81% compliance were achieved, and no adverse events were recorded. Participants' enjoyment was high and 38% started Zumba Gold(®) classes in the community after intervention. HR values were similar between dance styles and within the American College of Sports Medicine (ACSM)'s recommendations in 50% of participants. Backwards steps reduced physiological load but improvements in activity levels between the first and last sessions show that steps could be learnt with time. Zumba Gold(®) is safe and enjoyable for people with PD. The excellent compliance and positive participants' feedback suggest the need for a larger-scale trial. Copyright © 2016 Elsevier Ltd. All rights reserved.
Cescutti, Paola; Foschiatti, Michela; Furlanis, Linda; Lagatolla, Cristina; Rizzo, Roberto
2010-07-02
The repeating unit of cepacian, the exopolysaccharide produced by the majority of the microorganisms belonging to the Burkholderia cepacia complex, was isolated from inner bacterial membranes and investigated by mass spectrometry, with and without prior derivatisation. Interpretation of the mass spectra led to the determination of the biological repeating unit primary structure, thus disclosing the nature of the oligosaccharide produced in vivo. Moreover, mass spectra recorded on the native sample revealed that acetyl substitution was very variable, producing a mixture of repeating units containing zero to four acyl groups. At the same time, finding acetylated oligosaccharides showed that binding of these substituents occurred in the cellular periplasmic space, before the polymerisation process took place. In the chromatographic peak containing the repeating unit, oligosaccharides shorter than the repeating unit co-eluted. Mass spectrometric analysis showed that they were biosynthetic intermediates of the repeating unit and further investigation revealed the biosynthetic sequence of cepacian building block. Copyright 2010 Elsevier Ltd. All rights reserved.
DNA-binding proteins from marine bacteria expand the known sequence diversity of TALE-like repeats.
de Lange, Orlando; Wolf, Christina; Thiel, Philipp; Krüger, Jens; Kleusch, Christian; Kohlbacher, Oliver; Lahaye, Thomas
2015-11-16
Transcription Activator-Like Effectors (TALEs) of Xanthomonas bacteria are programmable DNA binding proteins with unprecedented target specificity. Comparative studies into TALE repeat structure and function are hindered by the limited sequence variation among TALE repeats. More sequence-diverse TALE-like proteins are known from Ralstonia solanacearum (RipTALs) and Burkholderia rhizoxinica (Bats), but RipTAL and Bat repeats are conserved with those of TALEs around the DNA-binding residue. We study two novel marine-organism TALE-like proteins (MOrTL1 and MOrTL2), the first to date of non-terrestrial origin. We have assessed their DNA-binding properties and modelled repeat structures. We found that repeats from these proteins mediate sequence specific DNA binding conforming to the TALE code, despite low sequence similarity to TALE repeats, and with novel residues around the BSR. However, MOrTL1 repeats show greater sequence discriminating power than MOrTL2 repeats. Sequence alignments show that there are only three residues conserved between repeats of all TALE-like proteins including the two new additions. This conserved motif could prove useful as an identifier for future TALE-likes. Additionally, comparing MOrTL repeats with those of other TALE-likes suggests a common evolutionary origin for the TALEs, RipTALs and Bats. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.
High-Temperature Extensometry and PdCr Temperature-Compensated Wire Resistance Strain Gages Compared
NASA Technical Reports Server (NTRS)
1997-01-01
A detailed experimental evaluation is underway at the NASA Lewis Research Center to compare and contrast the performance of the PdCr/Pt dual-element temperature-compensated wire resistance strain gage with that of conventional high-temperature extensometry. The advanced PdCr gage, developed by researchers at Lewis, exhibits desirable properties and a relatively small and repeatable apparent strain to 800 C. This gage represents a significant advance in technology because existing commercial resistance strain gages are not reliable for quasi-static strain measurements above approx. 400 C. Various thermal and mechanical loading spectra are being applied by a high-temperature thermomechanical uniaxial testing system to evaluate the two strain-measurement systems. This is being done not only to compare and contrast the two strain sensors, but also to investigate the applicability of the PdCr strain gage to the coupon-level specimen testing environment typically employed when the high-temperature mechanical behavior of structural materials is characterized. Strain measurement capabilities to 800 C are being investigated with a nickel-base superalloy, Inconel 100 (IN 100), substrate material and application to TMC's is being examined with the model system, SCS-6/Ti-15-3. Furthermore, two gage application techniques are being investigated in the comparison study: namely, flame-sprayed and spot welding. The apparent strain responses of both the weldable and flame-sprayed PdCr wire strain gages were found to be cyclically repeatable on both IN 100 and SCS-6/Ti-15-3 [0]_8. In general, each gage exhibited some uniqueness with respect to apparent strain behavior. Gages mounted on the IN 100 specimens tended to show a repeatable apparent strain within the first few cycles, because the thermal response of IN 100 was stable. This was not the case, however, for the TMC specimens, which typically required several thermal cycles to stabilize the thermal strain response. Thus, progressive changes in the apparent strain behavior were corroborated by the extensometer, which unlike the mounted gage can distinguish quantitative changes in the material's thermal strain response. One specimen was instrumented with both a fixed and floating gage. From the difference in output of these two gages, the thermal expansion strains were calculated. These data, which are given in the figure, show excellent agreement with the values measured by the high-temperature extensometry.
MSH3 polymorphisms and protein levels affect CAG repeat instability in Huntington's disease mice.
Tomé, Stéphanie; Manley, Kevin; Simard, Jodie P; Clark, Greg W; Slean, Meghan M; Swami, Meera; Shelbourne, Peggy F; Tillier, Elisabeth R M; Monckton, Darren G; Messer, Anne; Pearson, Christopher E
2013-01-01
Expansions of trinucleotide CAG/CTG repeats in somatic tissues are thought to contribute to ongoing disease progression through an affected individual's life with Huntington's disease or myotonic dystrophy. Broad ranges of repeat instability arise between individuals with expanded repeats, suggesting the existence of modifiers of repeat instability. Mice with expanded CAG/CTG repeats show variable levels of instability depending upon mouse strain. However, to date the genetic modifiers underlying these differences have not been identified. We show that in liver and striatum the R6/1 Huntington's disease (HD) (CAG)∼100 transgene, when present in a congenic C57BL/6J (B6) background, incurred expansion-biased repeat mutations, whereas the repeat was stable in a congenic BALB/cByJ (CBy) background. Reciprocal congenic mice revealed the Msh3 gene as the determinant for the differences in repeat instability. Expansion bias was observed in congenic mice homozygous for the B6 Msh3 gene on a CBy background, while the CAG tract was stabilized in congenics homozygous for the CBy Msh3 gene on a B6 background. The CAG stabilization was as dramatic as genetic deficiency of Msh2. The B6 and CBy Msh3 genes had identical promoters but differed in coding regions and showed strikingly different protein levels. B6 MSH3 variant protein is highly expressed and associated with CAG expansions, while the CBy MSH3 variant protein is expressed at barely detectable levels, associating with CAG stability. The DHFR protein, which is divergently transcribed from a promoter shared by the Msh3 gene, did not show varied levels between mouse strains. Thus, naturally occurring MSH3 protein polymorphisms are modifiers of CAG repeat instability, likely through variable MSH3 protein stability. Since evidence supports that somatic CAG instability is a modifier and predictor of disease, our data are consistent with the hypothesis that variable levels of CAG instability associated with polymorphisms of DNA repair genes may have prognostic implications for various repeat-associated diseases.
MSH3 Polymorphisms and Protein Levels Affect CAG Repeat Instability in Huntington's Disease Mice
Simard, Jodie P.; Clark, Greg W.; Slean, Meghan M.; Swami, Meera; Shelbourne, Peggy F.; Tillier, Elisabeth R. M.; Monckton, Darren G.; Messer, Anne; Pearson, Christopher E.
2013-01-01
Expansions of trinucleotide CAG/CTG repeats in somatic tissues are thought to contribute to ongoing disease progression through an affected individual's life with Huntington's disease or myotonic dystrophy. Broad ranges of repeat instability arise between individuals with expanded repeats, suggesting the existence of modifiers of repeat instability. Mice with expanded CAG/CTG repeats show variable levels of instability depending upon mouse strain. However, to date the genetic modifiers underlying these differences have not been identified. We show that in liver and striatum the R6/1 Huntington's disease (HD) (CAG)∼100 transgene, when present in a congenic C57BL/6J (B6) background, incurred expansion-biased repeat mutations, whereas the repeat was stable in a congenic BALB/cByJ (CBy) background. Reciprocal congenic mice revealed the Msh3 gene as the determinant for the differences in repeat instability. Expansion bias was observed in congenic mice homozygous for the B6 Msh3 gene on a CBy background, while the CAG tract was stabilized in congenics homozygous for the CBy Msh3 gene on a B6 background. The CAG stabilization was as dramatic as genetic deficiency of Msh2. The B6 and CBy Msh3 genes had identical promoters but differed in coding regions and showed strikingly different protein levels. B6 MSH3 variant protein is highly expressed and associated with CAG expansions, while the CBy MSH3 variant protein is expressed at barely detectable levels, associating with CAG stability. The DHFR protein, which is divergently transcribed from a promoter shared by the Msh3 gene, did not show varied levels between mouse strains. Thus, naturally occurring MSH3 protein polymorphisms are modifiers of CAG repeat instability, likely through variable MSH3 protein stability. Since evidence supports that somatic CAG instability is a modifier and predictor of disease, our data are consistent with the hypothesis that variable levels of CAG instability associated with polymorphisms of DNA repair genes may have prognostic implications for various repeat-associated diseases. PMID:23468640
Nagatomo, Daiki; Taniai, Madoka; Ariyasu, Harumi; Taniguchi, Mutsuko; Aga, Miho; Ariyasu, Toshio; Ohta, Tsunetaka; Fukuda, Shigeharu
2015-01-01
We encapsulated tumor necrosis factor-α (TNF-α), a major proinflammatory cytokine, into cholesteryl pullulan (CHP) to prepare TNF/CHP nanoparticles. In this report, we describe the immune-enhancing capability of the nanoparticles to act as a vaccine adjuvant. TNF/CHP nanoparticles showed excellent storage stability and enhanced host immune responses to external immunogens. The nanoparticles were effective via the nasal route of administration for inducing systemic IgG1 as well as mucosal IgA. We applied the nanoparticles in a model experimental influenza virus infection to investigate their adjuvant ability. TNF/CHP nanoparticles combined with a conventional split vaccine protected mice via nasal administration against a lethal challenge of A/PR/8/34 (H1N1) influenza virus. Mechanistic studies showed that the nanoparticles enhanced antigen uptake by dendritic cells (DCs) and moderately induced the expression of inflammation-related genes in nasopharynx lymphoid tissue (NALT), leading to the activation of both B and T cells. Preliminary safety study revealed no severe toxicity to TNF/CHP nanoparticles. Slight-to-moderate influences in nasal mucosa were observed only in the repeated administration and they seemed to be reversible. Our data show that TNF/CHP nanoparticles effectively enhance both humoral and cellular immunity and could be a potential adjuvant for vaccines against infectious diseases, especially in the mucosa. PMID:26421290
Kawakami, I; Shiraishi, S; Tsuda, M
2002-09-01
Ascidians are lower chordates and their simple tadpole-like larvae share a basic body plan with vertebrates. Newly hatched larvae show no response to a stimulus of light. 4 h after hatching, the larvae were induced to swim upon a step-down of light and stop swimming upon a step-up of light. At weaker intensity of light, the larvae show the same response to a stimulus after presentation of repeated stimuli. When intensity of actinic light was increased, the larvae show sensitization and habituation of the swimming response to a stimulus after repeated stimuli of step-down and step-up of the light. Between 2 h 20 min and 3 h 40 min after hatching the larvae did not show any response to the first stimulus, but after several repeatedstimuli they show swimming response to a step-down of light. A repeated series of stimulus cause sensitization. Between 4 h and 7 h after hatching, the larvae show photoresponse to the first stimulus, but after several repetition of the stimuli, the larvae could not stop swimming to a stimulus of a step-up of the actinic light. A repeated series of stimulus cause greaterhabituation. Both sensitization and habituation depend upon intensity ofactinic light.
All-photonic quantum repeaters
Azuma, Koji; Tamaki, Kiyoshi; Lo, Hoi-Kwong
2015-01-01
Quantum communication holds promise for unconditionally secure transmission of secret messages and faithful transfer of unknown quantum states. Photons appear to be the medium of choice for quantum communication. Owing to photon losses, robust quantum communication over long lossy channels requires quantum repeaters. It is widely believed that a necessary and highly demanding requirement for quantum repeaters is the existence of matter quantum memories. Here we show that such a requirement is, in fact, unnecessary by introducing the concept of all-photonic quantum repeaters based on flying qubits. In particular, we present a protocol based on photonic cluster-state machine guns and a loss-tolerant measurement equipped with local high-speed active feedforwards. We show that, with such all-photonic quantum repeaters, the communication efficiency scales polynomially with the channel distance. Our result paves a new route towards quantum repeaters with efficient single-photon sources rather than matter quantum memories. PMID:25873153
Jung, Soyeon; Chin, Hee Seung; Kim, Na Rae; Lee, Kang Won; Jung, Ji Won
2017-01-01
To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeatability was evaluated. The axial length (AL), anterior chamber depth (ACD), keratometry (K), white-to-white (WTW) corneal diameter, central corneal thickness (CCT), and lens thickness (LT) were measured and postoperative predictability was compared. Measurements could not be obtained with the IOLMaster 700 in one eye and in seven eyes with the Galilei G6 due to dense cataract. Both the IOLMaster 700 and Galilei G6 showed good repeatability, although the IOLMaster 700 showed better repeatability than the Galilei G6. There were no statistically significant differences in AL, ACD, steepest K, WTW, and LT ( P > 0.050), although flattest K, mean K, and CCT differed ( P < 0.050). The proportion of eyes with an absolute prediction error within 0.5 D was 85.0% for the IOLMaster 700 and was 80.0% for the Galilei G6 based on the SRK/T formula. Two biometers showed high repeatability and relatively good agreements. The swept-source optical biometer demonstrated better repeatability, penetration, and an overall lower prediction error.
High Temperature Brush Seal Tuft Testing of Selected Nickel-Chrome and Cobalt-Chrome Superalloys
NASA Technical Reports Server (NTRS)
Fellenstein, James A.; DellaCorte, Christopher; Moore, Kenneth D.; Boyes, Esther
1997-01-01
The tribology of brush seals is of considerable interest to turbine engine designers because bristle wear continues to limit long term seal performance and life. To provide better materials characterization and foster the development of improved seals, NASA Lewis has developed a brush seal tuft tester. In this test, a 'paintbrush' sample tuft is loaded under constant contact pressure against the outside diameter of a rotating journal. With this configuration, load and friction are directly measured and accurate wear measurements are possible. Previously reported research using this facility showed excellent data repeatability and wear morphology similar to published seal data and dynamic rig tests. This paper is an update of the ongoing research into the tribology of brush seals. The effects of wire materials processing on seal wear and the tribological results for three journal coatings are discussed. Included in the materials processing were two nickel-chrome superalloys each processed to two different yield strengths. The results suggest that seal wear is dependent more on material composition than processing conditions.
Juillet, Y; Dubois, C; Bintein, F; Dissard, J; Bossée, A
2014-08-01
A new rapid, sensitive and reliable method was developed for the determination of phosgene in air samples using thermal desorption (TD) followed by gas chromatography-mass spectrometry (GC-MS). The method is based on a fast (10 min) active sampling of only 1 L of air onto a Tenax® GR tube doped with 0.5 mL of derivatizing mixture containing dimercaptotoluene and triethylamine in hexane solution. Validation of the TD-GC-MS method showed a low limit of detection (40 ppbv), acceptable repeatability, intermediate fidelity (relative standard deviation within 12 %) and excellent accuracy (>95%). Linearity was demonstrated for two concentration ranges (0.04 to 2.5 ppmv and 2.5 to 10 ppmv) owing to variation of derivatization recovery between low and high concentration levels. Due to its simple on-site implementation and its close similarity with recommended operating procedure (ROP) for chemical warfare agents vapour sampling, the method is particularly useful in the process of verification of the Chemical Weapons Convention.
Devos, Christophe; David, Frank; Sandra, Pat
2012-10-26
According to recent directives of the European Union (EU), limits of quantification (LOQ) for the determination of tributyltin (TBT) in surface waters should be ca. 60 pg/L (ppq). This put very stringent requirements on analytical methodologies; definitely when they have to be applied in a routine environment. Stir bar sorptive extraction (SBSE), followed by thermal desorption (TD) and capillary gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS) can provide accurate and precise data at the 2 ng/L level (ppt). For lower concentrations, matrix and reagent interferences together with contamination may provide too high TBT values. A two-dimensional heart-cut GC method was developed to fractionate TBT from interferences. The GC-GC-MS/MS method shows excellent linearity in the range 50 pg/L-4 ng/L, good repeatability (RSD<20% at 200 pg/L), and a limit of detection of 11 pg/L. The method performance is demonstrated with representative samples i.e. harbor water and waste water samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Ciftci, Hakan; Oztekin, Yasemin; Tamer, Ugur; Ramanaviciene, Almira; Ramanavicius, Arunas
2014-11-01
This study is focused on the investigation of electrocatalytic effect of glucose oxidase (GOx) immobilized on the graphite rod (GR) electrode. The enzyme modified electrode was prepared by encapsulation of immobilized GOx within enzymatically formed poly(1,10-phenanthroline-5,6-dione) (pPD) film. The electrochemical responses of such enzymatic electrode (pPD/GOx/GR) vs. different glucose concentrations were examined chronoamperometrically in acetate-phosphate buffer solution (A-PBS), pH 6.0, under aerobic or anaerobic conditions. Amperometric signals of the pPD/GOx/GR electrode exhibited well-defined hyperbolic dependence upon glucose concentration. Amperometric signals at 100mM of glucose were 41.17 and 32.27 μA under aerobic and anaerobic conditions, respectively. Amperometric signals of the pPD/GOx/GR electrode decreased by 6% within seven days. The pPD/GOx/GR electrode showed excellent selectivity in the presence of dopamine and uric acid. Furthermore it had a good reproducibility and repeatability with standard deviation of 9.4% and 8.0%, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.
Diester Molecules for Organic-Based Electrical and Photoelectrical Devices
NASA Astrophysics Data System (ADS)
Topal, Giray; Tombak, Ahmet; Yigitalp, Esref; Batibay, Derya; Kilicoglu, Tahsin; Ocak, Yusuf Selim
2017-07-01
Diester derivatives of terephthalic acid molecules were synthesized according to the literature. Au/Diester derivatives/ n-Si organic-inorganic (OI) heterojunction-type devices were fabricated, and the current-voltage ( I- V) characteristics of the devices have been investigated at room temperature. I- V characteristics demonstrated that all diodes had excellent rectification properties. Primary diode parameters such as series resistance and barrier height were extracted by using semi-log I- V plots and Norde methods, and were compared. It was seen that there was a substantial agreement between results obtained from two methods. Calculated barrier height values were about the same with 0.02-eV differences that were attributed to the series resistance. Ideality factors, which show how the diode closes to ideal diodes, were also extracted from semi-log I- V plots. Thus, the modification of the Au/ n-Si diode potential barrier was accomplished using diester derivatives as an interlayer. The I- V measurements were repeated to characterize the devices at 100 mW/cm2 illumination intensity with the help of a solar simulator with an AM1.5G filter.
Stipcovich, Tea; Barbero, Gerardo F; Ferreiro-González, Marta; Palma, Miguel; Barroso, Carmelo G
2018-01-15
A rapid high-performance liquid chromatography method with a C18 reverse-phase fused-core column has been developed for the determination and quantification of the main capsaicinoids (nornordihydrocapsaicin, nordihydrocapsaicin, capsaicin, dihydrocapsaicin, homocapsaicin and homodihydrocapsaicin) present in Naga Jolokia peppers. A fused-core Kinetex™ C18 column (50×2.1mm i.d.; 2.6μm) was used for the analysis. The chromatographic separation was obtained with a gradient method in which the mobile phase was water (0.1% acetic acid) as solvent A and acetonitrile (0.1% acetic acid) as solvent B. The separation of all compounds was achieved in less than 3min with a total analysis time (sample-to-sample) of 10min. The robustness of the method was evaluated. The method showed excellent repeatability and intermediate precision expressed as coefficient of variance of less than 2%. The developed method was employed for the quantification of the major capsaicinoids present in different peppers and commercial products containing chilli peppers. Copyright © 2017 Elsevier Ltd. All rights reserved.
CMOS integration of inkjet-printed graphene for humidity sensing.
Santra, S; Hu, G; Howe, R C T; De Luca, A; Ali, S Z; Udrea, F; Gardner, J W; Ray, S K; Guha, P K; Hasan, T
2015-11-30
We report on the integration of inkjet-printed graphene with a CMOS micro-electro-mechanical-system (MEMS) microhotplate for humidity sensing. The graphene ink is produced via ultrasonic assisted liquid phase exfoliation in isopropyl alcohol (IPA) using polyvinyl pyrrolidone (PVP) polymer as the stabilizer. We formulate inks with different graphene concentrations, which are then deposited through inkjet printing over predefined interdigitated gold electrodes on a CMOS microhotplate. The graphene flakes form a percolating network to render the resultant graphene-PVP thin film conductive, which varies in presence of humidity due to swelling of the hygroscopic PVP host. When the sensors are exposed to relative humidity ranging from 10-80%, we observe significant changes in resistance with increasing sensitivity from the amount of graphene in the inks. Our sensors show excellent repeatability and stability, over a period of several weeks. The location specific deposition of functional graphene ink onto a low cost CMOS platform has the potential for high volume, economic manufacturing and application as a new generation of miniature, low power humidity sensors for the internet of things.
CMOS integration of inkjet-printed graphene for humidity sensing
Santra, S.; Hu, G.; Howe, R. C. T.; De Luca, A.; Ali, S. Z.; Udrea, F.; Gardner, J. W.; Ray, S. K.; Guha, P. K.; Hasan, T.
2015-01-01
We report on the integration of inkjet-printed graphene with a CMOS micro-electro-mechanical-system (MEMS) microhotplate for humidity sensing. The graphene ink is produced via ultrasonic assisted liquid phase exfoliation in isopropyl alcohol (IPA) using polyvinyl pyrrolidone (PVP) polymer as the stabilizer. We formulate inks with different graphene concentrations, which are then deposited through inkjet printing over predefined interdigitated gold electrodes on a CMOS microhotplate. The graphene flakes form a percolating network to render the resultant graphene-PVP thin film conductive, which varies in presence of humidity due to swelling of the hygroscopic PVP host. When the sensors are exposed to relative humidity ranging from 10–80%, we observe significant changes in resistance with increasing sensitivity from the amount of graphene in the inks. Our sensors show excellent repeatability and stability, over a period of several weeks. The location specific deposition of functional graphene ink onto a low cost CMOS platform has the potential for high volume, economic manufacturing and application as a new generation of miniature, low power humidity sensors for the internet of things. PMID:26616216
Engelken, Florian; Wassilew, Georgi I; Köhlitz, Torsten; Brockhaus, Sebastian; Hamm, Bernd; Perka, Carsten; Diederichs, und Gerd
2014-01-01
The purpose of this study was to quantify the performance of the Goutallier classification for assessing fatty degeneration of the gluteus muscles from magnetic resonance (MR) images and to compare its performance to a newly proposed system. Eighty-four hips with clinical signs of gluteal insufficiency and 50 hips from asymptomatic controls were analyzed using a standard classification system (Goutallier) and a new scoring system (Quartile). Interobserver reliability and intraobserver repeatability were determined, and accuracy was assessed by comparing readers' scores with quantitative estimates of the proportion of intramuscular fat based on MR signal intensities (gold standard). The existing Goutallier classification system and the new Quartile system performed equally well in assessing fatty degeneration of the gluteus muscles, both showing excellent levels of interrater and intrarater agreement. While the Goutallier classification system has the advantage of being widely known, the benefit of the Quartile system is that it is based on more clearly defined grades of fatty degeneration. Copyright © 2014 Elsevier Inc. All rights reserved.
Long Term Influence of Carbon Nanoparticles on Health and Liver Status in Rats
Strojny, Barbara; Kurantowicz, Natalia; Sawosz, Ewa; Grodzik, Marta; Jaworski, Sławomir; Kutwin, Marta; Wierzbicki, Mateusz; Hotowy, Anna; Lipińska, Ludwika; Chwalibog, André
2015-01-01
Due to their excellent biocompatibility, carbon nanoparticles have been widely investigated for prospective biomedical applications. However, their impact on an organism with prolonged exposure is still not well understood. Here, we performed an experiment investigating diamond, graphene oxide and graphite nanoparticles, which were repeatedly administrated intraperitoneally into Wistar rats for four weeks. Some of the animals was sacrificed after the last injection, whereas the rest were sacrificed twelve weeks after the last exposure. We evaluated blood morphology and biochemistry, as well as the redox and inflammatory state of the liver. The results show the retention of nanoparticles within the peritoneal cavity in the form of prominent aggregates in proximity to the injection site, as well as the presence of some nanoparticles in the mesentery. Small aggregates were also visible in the liver serosa, suggesting possible transportation to the liver. However, none of the tested nanoparticles affected the health of animals. This lack of toxic effect may suggest the potential applicability of nanoparticles as drug carriers for local therapies, ensuring accumulation and slow release of drugs into a targeted tissue without harmful systemic side effects. PMID:26657282
Long Term Influence of Carbon Nanoparticles on Health and Liver Status in Rats.
Strojny, Barbara; Kurantowicz, Natalia; Sawosz, Ewa; Grodzik, Marta; Jaworski, Sławomir; Kutwin, Marta; Wierzbicki, Mateusz; Hotowy, Anna; Lipińska, Ludwika; Chwalibog, André
2015-01-01
Due to their excellent biocompatibility, carbon nanoparticles have been widely investigated for prospective biomedical applications. However, their impact on an organism with prolonged exposure is still not well understood. Here, we performed an experiment investigating diamond, graphene oxide and graphite nanoparticles, which were repeatedly administrated intraperitoneally into Wistar rats for four weeks. Some of the animals was sacrificed after the last injection, whereas the rest were sacrificed twelve weeks after the last exposure. We evaluated blood morphology and biochemistry, as well as the redox and inflammatory state of the liver. The results show the retention of nanoparticles within the peritoneal cavity in the form of prominent aggregates in proximity to the injection site, as well as the presence of some nanoparticles in the mesentery. Small aggregates were also visible in the liver serosa, suggesting possible transportation to the liver. However, none of the tested nanoparticles affected the health of animals. This lack of toxic effect may suggest the potential applicability of nanoparticles as drug carriers for local therapies, ensuring accumulation and slow release of drugs into a targeted tissue without harmful systemic side effects.
Demonstration test of burner liner strain measuring system
NASA Technical Reports Server (NTRS)
Stetson, K. A.
1984-01-01
A demonstration test was conducted for two systems of static strain measurement that had been shown to have potential for application jet engine combustors. A modified JT12D combustor was operated in a jet burner test stand while subjected simultaneously to both systems of instrumentation, i.e., Kanthal A-1 wire strain gages and laser speckle photography. A section of the burner was removed for installation and calibration of the wire gages, and welded back into the burner. The burner test rig was modified to provide a viewing port for the laser speckle photography such that the instrumented section could be observed during operation. Six out of ten wire gages survived testing and showed excellent repeatability. The extensive precalibration procedures were shown to be effective in compensating for the large apparent strains associated with these gages. Although all portions of the speckle photography system operated satisfactorily, a problem was encountered in the form of optical inhomogeneities in the hot, high-pressure gas flowing by the combustor case which generate large and random apparent strain distributions.
Direct growth of freestanding GaN on C-face SiC by HVPE.
Tian, Yuan; Shao, Yongliang; Wu, Yongzhong; Hao, Xiaopeng; Zhang, Lei; Dai, Yuanbin; Huo, Qin
2015-06-02
In this work, high quality GaN crystal was successfully grown on C-face 6H-SiC by HVPE using a two steps growth process. Due to the small interaction stress between the GaN and the SiC substrate, the GaN was self-separated from the SiC substrate even with a small thickness of about 100 μm. Moreover, the SiC substrate was excellent without damage after the whole process so that it can be repeatedly used in the GaN growth. Hot phosphoric acid etching (at 240 °C for 30 min) was employed to identify the polarity of the GaN layer. According to the etching results, the obtained layer was Ga-polar GaN. High-resolution X-ray diffraction (HRXRD) and electron backscatter diffraction (EBSD) were done to characterize the quality of the freestanding GaN. The Raman measurements showed that the freestanding GaN film grown on the C-face 6H-SiC was stress-free. The optical properties of the freestanding GaN layer were determined by photoluminescence (PL) spectra.
Extending the solvent-free MALDI sample preparation method.
Hanton, Scott D; Parees, David M
2005-01-01
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is an important technique to characterize many different materials, including synthetic polymers. MALDI mass spectral data can be used to determine the polymer average molecular weights, repeat units, and end groups. One of the key issues in traditional MALDI sample preparation is making good solutions of the analyte and the matrix. Solvent-free sample preparation methods have been developed to address these issues. Previous results of solvent-free or dry prepared samples show some advantages over traditional wet sample preparation methods. Although the results of the published solvent-free sample preparation methods produced excellent mass spectra, we found the method to be very time-consuming, with significant tool cleaning, which presents a significant possibility of cross contamination. To address these issues, we developed an extension of the solvent-free method that replaces the mortar and pestle grinding with ball milling the sample in a glass vial with two small steel balls. This new method generates mass spectra with equal quality of the previous methods, but has significant advantages in productivity, eliminates cross contamination, and is applicable to liquid and soft or waxy analytes.
CMOS integration of inkjet-printed graphene for humidity sensing
NASA Astrophysics Data System (ADS)
Santra, S.; Hu, G.; Howe, R. C. T.; de Luca, A.; Ali, S. Z.; Udrea, F.; Gardner, J. W.; Ray, S. K.; Guha, P. K.; Hasan, T.
2015-11-01
We report on the integration of inkjet-printed graphene with a CMOS micro-electro-mechanical-system (MEMS) microhotplate for humidity sensing. The graphene ink is produced via ultrasonic assisted liquid phase exfoliation in isopropyl alcohol (IPA) using polyvinyl pyrrolidone (PVP) polymer as the stabilizer. We formulate inks with different graphene concentrations, which are then deposited through inkjet printing over predefined interdigitated gold electrodes on a CMOS microhotplate. The graphene flakes form a percolating network to render the resultant graphene-PVP thin film conductive, which varies in presence of humidity due to swelling of the hygroscopic PVP host. When the sensors are exposed to relative humidity ranging from 10-80%, we observe significant changes in resistance with increasing sensitivity from the amount of graphene in the inks. Our sensors show excellent repeatability and stability, over a period of several weeks. The location specific deposition of functional graphene ink onto a low cost CMOS platform has the potential for high volume, economic manufacturing and application as a new generation of miniature, low power humidity sensors for the internet of things.
The processive kinetics of gene conversion in bacteria
Paulsson, Johan; El Karoui, Meriem; Lindell, Monica
2017-01-01
Summary Gene conversion, non‐reciprocal transfer from one homologous sequence to another, is a major force in evolutionary dynamics, promoting co‐evolution in gene families and maintaining similarities between repeated genes. However, the properties of the transfer – where it initiates, how far it proceeds and how the resulting conversion tracts are affected by mismatch repair – are not well understood. Here, we use the duplicate tuf genes in Salmonella as a quantitatively tractable model system for gene conversion. We selected for conversion in multiple different positions of tuf, and examined the resulting distributions of conversion tracts in mismatch repair‐deficient and mismatch repair‐proficient strains. A simple stochastic model accounting for the essential steps of conversion showed excellent agreement with the data for all selection points using the same value of the conversion processivity, which is the only kinetic parameter of the model. The analysis suggests that gene conversion effectively initiates uniformly at any position within a tuf gene, and proceeds with an effectively uniform conversion processivity in either direction limited by the bounds of the gene. PMID:28256783
Surface plasmon resonance immunoassay analysis of pituitary hormones in urine and serum samples.
Treviño, Juan; Calle, Ana; Rodríguez-Frade, José Miguel; Mellado, Mario; Lechuga, Laura M
2009-05-01
Direct determination of four pituitary peptide hormones: human thyroid stimulating hormone (hTSH), growth hormone (hGH), follicle stimulating hormone (hFSH), and luteinizing hormone (hLH) has been carried out using a portable surface plasmon resonance (SPR) immunosensor. A commercial SPR biosensor was employed. The immobilization of the hormones was optimized and monoclonal antibodies were selected in order to obtain the best sensor performance. Assay parameters as running buffer and regeneration solution composition or antibody concentration were adjusted to achieve a sensitive analyte detection. The performance of the assays was assessed in buffer solution, serum and urine, showing sensitivity in the range from 1 to 6 ng/mL. The covalent attachment of the hormones ensured the stability of the SPR signal through repeated use in up to 100 consecutive assay cycles. Mean intra- and inter-day coefficients of variation were all <7%, while batch-assay variability using different sensor surfaces was <5%. Taking account both the excellent reutilization performance and the outstanding reproducibility, this SPR immunoassay method turns on a highly reliable tool for endocrine monitoring in laboratory and point-of-care (POC) settings.
Macedo, Fabio; Marsico, Eliane Teixeira; Conte-Júnior, Carlos Adam; de Resende, Michele Fabri; Brasil, Taila Figueiredo; Pereira Netto, Annibal Duarte
2015-07-15
An analytical method was developed and validated for the simultaneous determination of four macrocyclic lactones (ML) (abamectin, doramectin, ivermectin and moxidectin) in butter, using liquid chromatography with fluorescence detection. The method employed heated liquid-liquid extraction and a mixture of acetonitrile, ethyl acetate and water, with preconcentration and derivatization, to produce stable fluorescent derivatives. The chromatographic run time was <12.5 min, with excellent separation. The method validation followed international guidelines and employed fortified butter samples. The figures of merit obtained, e.g. recovery (72.4-106.5%), repeatability (8.8%), within-laboratory reproducibility (15.7%) and limits of quantification (0.09-0.16 μg kg(-1)) were satisfactory for the desired application. The application of the method to real samples showed that ML residues were present in six of the ten samples evaluated. The method proved to be simple, easy and appropriate for simultaneous determination of ML residues in butter. To our knowledge, this is the first method described for the evaluation of ML in butter. Copyright © 2015. Published by Elsevier Ltd.
Umamaheswari, Selvaraj; Mainzen Prince, Ponnaian Stanely
2007-01-01
'Ilogen-Excel', an Ayurvedic herbal formulation is composed of eight medicinal plants (Curcuma longa, Strychnos potatorum, Salacia oblonga, Tinospora cordifolia, Vetivelia zizanioides, Coscinium fenestratum, Andrographis paniculata and Mimosa pudica). The present study evaluates the antihyperglycemic effect of 'Ilogen-Excel' in streptozotocin induced diabetic rats. Rats were rendered diabetic by streptozotocin (STZ) (45 mg/kg body weight). Oral administration of 'Ilogen-Excel' (50 mg/kg and 100 mg/kg) for 60 days resulted in significantly lowered levels of blood glucose and significantly increased levels of plasma insulin, hepatic glycogen and total hemoglobin. 'Ilogen-Excel' administration also decreased the levels of glycosylated hemoglobin, plasma thiobarbituric acid reactive substances, hydroperoxides, ceruloplasmin and vitamin E in diabetic rats. Plasma reduced glutathione and vitamin C were significantly elevated by oral administration of 'Ilogen-Excel'. Administration of insulin normalized all the biochemical parameters studied in diabetic rats. The effect at a dose of 100 mg/kg was more pronounced than 50 mg/kg and brought back all the parameters to near normal levels. Thus, our study shows the antihyperglycemic effects of 'Ilogen-Excel' in STZ-induced diabetic rats. Our study also shows that combined therapy is better than individual therapy.
Translation, reliability, and clinical utility of the Melbourne Assessment 2.
Gerber, Corinna N; Plebani, Anael; Labruyère, Rob
2017-10-12
The aims were to (i) provide a German translation of the Melbourne Assessment 2 (MA2), a quantitative test to measure unilateral upper limb function in children with neurological disabilities and (ii) to evaluate its reliability and aspects of clinical utility. After its translation into German and approval of the back translation by the original authors, the MA2 was performed and videotaped twice with 30 children with neuromotor disorders. For each participant, two raters scored the video of the first test for inter-rater reliability. To determine test-retest reliability, one rater additionally scored the video of the second test while the other rater repeated the scoring of the first video to evaluate intra-rater reliability. Time needed for rater training, test administration, and scoring was recorded. The four subscale scores showed excellent intra-, inter-rater, and test-retest reliability with intraclass correlation coefficients of 0.90-1.00 (95%-confidence intervals 0.78-1.00). Score items revealed substantial to almost perfect intra-rater reliability (weighted kappa k w = 0.66-1.00) for the more affected side. Score item inter-rater and test-retest reliability of the same extremity were, with one exception, moderate to almost perfect (k w = 0.42-0.97; k w = 0.40-0.89). Furthermore, the MA2 was feasible and acceptable for patients and clinicians. The MA2 showed excellent subscale and moderate to almost perfect score item reliability. Implications for Rehabilitation There is a lack of high-quality studies about psychometric properties of upper limb measurement tools in the neuropediatric population. The Melbourne Assessment 2 is a promising tool for reliable measurement of unilateral upper limb movement quality in the neuropediatric population. The Melbourne Assessment 2 is acceptable and practicable to therapists and patients for routine use in clinical care.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, Syam; Sitha
2015-06-15
Purpose: Determination of source dwell positions of HDR brachytherapy using 2D 729 ion chamber array Methods: Nucletron microselectron HDR and PTW 2D array were used for the study. Different dwell positions were assigned in the HDR machine. Rigid interstitial needles and vaginal applicator were positioned on the 2D array. The 2D array was exposed for this programmed dwell positions. The positional accuracy of the source was analyzed after the irradiation of the 2D array. This was repeated for different dwell positions. Different test plans were transferred from the Oncentra planning system and irradiated with the same applicator position on themore » 2D array. The results were analyzed using the in house developed excel program. Results: Assigned dwell positions versus corresponding detector response were analyzed. The results show very good agreement with the film measurements. No significant variation found between the planned and measured dwell positions. Average dose response with 2D array between the planned and nearby dwell positions was found to be 0.0804 Gy for vaginal cylinder applicator and 0.1234 Gy for interstitial rigid needles. Standard deviation between the doses for all the measured dwell positions for interstitial rigid needle for 1 cm spaced positions were found to be 0.33 and 0.37 for 2cm spaced dwell positions. For intracavitory vaginal applicator this was found to be 0.21 for 1 cm spaced dwell positions and 0.06 for 2cm spaced dwell positions. Intracavitory test plans reproduced on the 2D array with the same applicator positions shows the ideal dose distribution with the TPS planned. Conclusion: 2D array is a good tool for determining the dwell position of HDR brachytherapy. With the in-house developed program in excel it is easy and accurate. The traditional way with film analysis can be replaced by this method, as the films will be more costly.« less
Taborri, Juri; Rossi, Stefano; Palermo, Eduardo; Patanè, Fabrizio; Cappa, Paolo
2014-01-01
In this work, we decided to apply a hierarchical weighted decision, proposed and used in other research fields, for the recognition of gait phases. The developed and validated novel distributed classifier is based on hierarchical weighted decision from outputs of scalar Hidden Markov Models (HMM) applied to angular velocities of foot, shank, and thigh. The angular velocities of ten healthy subjects were acquired via three uni-axial gyroscopes embedded in inertial measurement units (IMUs) during one walking task, repeated three times, on a treadmill. After validating the novel distributed classifier and scalar and vectorial classifiers-already proposed in the literature, with a cross-validation, classifiers were compared for sensitivity, specificity, and computational load for all combinations of the three targeted anatomical segments. Moreover, the performance of the novel distributed classifier in the estimation of gait variability in terms of mean time and coefficient of variation was evaluated. The highest values of specificity and sensitivity (>0.98) for the three classifiers examined here were obtained when the angular velocity of the foot was processed. Distributed and vectorial classifiers reached acceptable values (>0.95) when the angular velocity of shank and thigh were analyzed. Distributed and scalar classifiers showed values of computational load about 100 times lower than the one obtained with the vectorial classifier. In addition, distributed classifiers showed an excellent reliability for the evaluation of mean time and a good/excellent reliability for the coefficient of variation. In conclusion, due to the better performance and the small value of computational load, the here proposed novel distributed classifier can be implemented in the real-time application of gait phases recognition, such as to evaluate gait variability in patients or to control active orthoses for the recovery of mobility of lower limb joints. PMID:25184488
Smith, Seth A; Farrell, Jonathan A D; Jones, Craig K; Reich, Daniel S; Calabresi, Peter A; van Zijl, Peter C M
2006-10-01
Pulsed magnetization transfer (MT) imaging has been applied to quantitatively assess brain pathology in several diseases, especially multiple sclerosis (MS). To date, however, because of the high power deposition associated with the use of short, rapidly repeating MT prepulses, clinical application has been limited to lower field strengths. The contrast-to-noise ratio (CNR) of MT is limited, and this method would greatly benefit from the use of higher magnetic fields and phased-array coil reception. However, power deposition is proportional to the square of the magnetic field and scales with coil size, and MT experiments are already close to the SAR limit at 1.5T even when smaller transmit coils are used instead of the body coil. Here we show that these seemingly great obstacles can be ameliorated by the increased T(1) of tissue water at higher field, which allows for longer maintenance of sufficiently high saturation levels while using a reduced duty cycle. This enables a fast (5-6 min) high-resolution (1.5 mm isotropic) whole-brain MT acquisition with excellent anatomical visualization of gray matter (GM) and white matter (WM) structures, and even substructures. The method is demonstrated in nine normal volunteers and five patients with relapsing remitting MS (RRMS), and the results show a clear delineation of heterogeneous lesions.
Huang, Mengqi; Zhou, Xiaoming; Wang, Huiying; Xing, Da
2018-02-06
A novel CRISPR/Cas9 triggered isothermal exponential amplification reaction (CAS-EXPAR) strategy based on CRISPR/Cas9 cleavage and nicking endonuclease (NEase) mediated nucleic acids amplification was developed for rapid and site-specific nucleic acid detection. CAS-EXPAR was primed by the target DNA fragment produced by cleavage of CRISPR/Cas9, and the amplification reaction performed cyclically to generate a large number of DNA replicates which were detected using a real-time fluorescence monitoring method. This strategy that combines the advantages of CRISPR/Cas9 and exponential amplification showed high specificity as well as rapid amplification kinetics. Unlike conventional nucleic acids amplification reactions, CAS-EXPAR does not require exogenous primers, which often cause target-independent amplification. Instead, primers are first generated by Cas9/sgRNA directed site-specific cleavage of target and accumulated during the reaction. It was demonstrated this strategy gave a detection limit of 0.82 amol and showed excellent specificity in discriminating single-base mismatch. Moreover, the applicability of this method to detect DNA methylation and L. monocytogenes total RNA was also verified. Therefore, CAS-EXPAR may provide a new paradigm for efficient nucleic acid amplification and hold the potential for molecular diagnostic applications.
Xu, Guochuang; Zhang, Miao; Zhou, Qinqin; Chen, Hongwu; Gao, Tiantian; Li, Chun; Shi, Gaoquan
2017-11-16
A high-performance actuator should be able to deliver large-shape deformations, fast actuations and sensitive responses to multiple stimuli. Here, we report such an actuator constructed from one layer of polyvinylidene fluoride (PVDF) with a high coefficient of thermal expansion (CTE), and another layer of small sheets of graphene oxide (SGO) with a negative CTE. The opposite deformations of both actuation layers make the SGO/PVDF bilayer actuator highly sensitive to the temperature stimulus with a large bending sensitivity of 1.5 cm -1 °C -1 . Upon irradiation with 60 mW cm -2 infrared light, this SGO/PVDF bilayer actuator displayed an extremely rapid tip displacement rate of 140 mm s -1 . Furthermore, this actuator can also sensitively respond to moisture because of its SGO layer, showing a curvature change from -22 to 13 cm -1 upon changing the relative humidity (RH) from 11% to 86%. This actuator can generate a contractile or relaxed stress 18 times that of mammalian skeletal muscle, under light irradiation or moisture with a response time as short as 1 s, being capable of lifting an object with a weight 80 times that of itself. Furthermore, it also showed excellent stability and repeatability.
Molecular characterization and distribution of a 145-bp tandem repeat family in the genus Populus.
Rajagopal, J; Das, S; Khurana, D K; Srivastava, P S; Lakshmikumaran, M
1999-10-01
This report aims to describe the identification and molecular characterization of a 145-bp tandem repeat family that accounts for nearly 1.5% of the Populus genome. Three members of this repeat family were cloned and sequenced from Populus deltoides and P. ciliata. The dimers of the repeat were sequenced in order to confirm the head-to-tail organization of the repeat. Hybridization-based analysis using the 145-bp tandem repeat as a probe on genomic DNA gave rise to ladder patterns which were identified to be a result of methylation and (or) sequence heterogeneity. Analysis of the methylation pattern of the repeat family using methylation-sensitive isoschizomers revealed variable methylation of the C residues and lack of methylation of the A residues. Sequence comparisons between the monomers revealed a high degree of sequence divergence that ranged between 6% and 11% in P. deltoides and between 4.2% and 8.3% in P. ciliata. This indicated the presence of sub-families within the 145-bp tandem family of repeats. Divergence was mainly due to the accumulation of point mutations and was concentrated in the central region of the repeat. The 145-bp tandem repeat family did not show significant homology to known tandem repeats from plants. A short stretch of 36 bp was found to show homology of 66.7% to a centromeric repeat from Chironomus plumosus. Dot-blot analysis and Southern hybridization data revealed the presence of the repeat family in 13 of the 14 Populus species examined. The absence of the 145-bp repeat from P. euphratica suggested that this species is relatively distant from other members of the genus, which correlates with taxonomic classifications. The widespread occurrence of the tandem family in the genus indicated that this family may be of ancient origin.
Automated extraction and validation of children's gait parameters with the Kinect.
Motiian, Saeid; Pergami, Paola; Guffey, Keegan; Mancinelli, Corrie A; Doretto, Gianfranco
2015-12-02
Gait analysis for therapy regimen prescription and monitoring requires patients to physically access clinics with specialized equipment. The timely availability of such infrastructure at the right frequency is especially important for small children. Besides being very costly, this is a challenge for many children living in rural areas. This is why this work develops a low-cost, portable, and automated approach for in-home gait analysis, based on the Microsoft Kinect. A robust and efficient method for extracting gait parameters is introduced, which copes with the high variability of noisy Kinect skeleton tracking data experienced across the population of young children. This is achieved by temporally segmenting the data with an approach based on coupling a probabilistic matching of stride template models, learned offline, with the estimation of their global and local temporal scaling. A preliminary study conducted on healthy children between 2 and 4 years of age is performed to analyze the accuracy, precision, repeatability, and concurrent validity of the proposed method against the GAITRite when measuring several spatial and temporal children's gait parameters. The method has excellent accuracy and good precision, with segmenting temporal sequences of body joint locations into stride and step cycles. Also, the spatial and temporal gait parameters, estimated automatically, exhibit good concurrent validity with those provided by the GAITRite, as well as very good repeatability. In particular, on a range of nine gait parameters, the relative and absolute agreements were found to be good and excellent, and the overall agreements were found to be good and moderate. This work enables and validates the automated use of the Kinect for children's gait analysis in healthy subjects. In particular, the approach makes a step forward towards developing a low-cost, portable, parent-operated in-home tool for clinicians assisting young children.
Rasmussen, Helle Mätzke; Nielsen, Dennis Brandborg; Pedersen, Niels Wisbech; Overgaard, Søren; Holsgaard-Larsen, Anders
2015-07-01
The Gait Deviation Index (GDI) and Gait Profile Score (GPS) are the most used summary measures of gait in children with cerebral palsy (CP). However, the reliability and agreement of these indices have not been investigated, limiting their clinimetric quality for research and clinical practice. The aim of this study was to investigate the intra-rater reliability and agreement of summary measures of gait (GDI; GPS; and the Gait Variable Score (GVS) derived from the GPS). The intra-rater reliability and agreement were investigated across two repeated sessions in 18 children aged 5-12 years diagnosed with spastic CP. No systematic bias was observed between the sessions and no heteroscedasticity was observed in Bland-Altman plots. For the GDI and GPS, excellent reliability with intraclass correlation coefficient (ICC) values of 0.8-0.9 was found, while the GVS was found to have fair to good reliability with ICCs of 0.4-0.7. The agreement for the GDI and the logarithmically transformed GPS, in terms of the standard error of measurement as a percentage of the grand mean (SEM%) varied from 4.1 to 6.7%, whilst the smallest detectable change in percent (SDC%) ranged from 11.3 to 18.5%. For the logarithmically transformed GVS, we found a fair to large variation in SEM% from 7 to 29% and in SDC% from 18 to 81%. The GDI and GPS demonstrated excellent reliability and acceptable agreement proving that they can both be used in research and clinical practice. However, the observed large variability for some of the GVS requires cautious consideration when selecting outcome measures. Copyright © 2015 Elsevier B.V. All rights reserved.
Computer-based Astronomy Labs for Non-science Majors
NASA Astrophysics Data System (ADS)
Smith, A. B. E.; Murray, S. D.; Ward, R. A.
1998-12-01
We describe and demonstrate two laboratory exercises, Kepler's Third Law and Stellar Structure, which are being developed for use in an astronomy laboratory class aimed at non-science majors. The labs run with Microsoft's Excel 98 (Macintosh) or Excel 97 (Windows). They can be run in a classroom setting or in an independent learning environment. The intent of the labs is twofold; first and foremost, students learn the subject matter through a series of informational frames. Next, students enhance their understanding by applying their knowledge in lab procedures, while also gaining familiarity with the use and power of a widely-used software package and scientific tool. No mathematical knowledge beyond basic algebra is required to complete the labs or to understand the computations in the spreadsheets, although the students are exposed to the concepts of numerical integration. The labs are contained in Excel workbook files. In the files are multiple spreadsheets, which contain either a frame with information on how to run the lab, material on the subject, or one or more procedures. Excel's VBA macro language is used to automate the labs. The macros are accessed through button interfaces positioned on the spreadsheets. This is done intentionally so that students can focus on learning the subject matter and the basic spreadsheet features without having to learn advanced Excel features all at once. Students open the file and progress through the informational frames to the procedures. After each procedure, student comments and data are automatically recorded in a preformatted Lab Report spreadsheet. Once all procedures have been completed, the student is prompted for a filename in which to save their Lab Report. The lab reports can then be printed or emailed to the instructor. The files will have full worksheet and workbook protection, and will have a "redo" feature at the end of the lab for students who want to repeat a procedure.
Baron, Suzanne J; Chinnakondepalli, Khaja; Magnuson, Elizabeth A; Kandzari, David E; Puskas, John D; Ben-Yehuda, Ori; van Es, Gerrit-Anne; Taggart, David P; Morice, Marie-Claude; Lembo, Nicholas J; Brown, W Morris; Banning, Adrian; Simonton, Charles A; Kappetein, A Pieter; Sabik, Joseph F; Serruys, Patrick W; Stone, Gregg W; Cohen, David J
2017-12-26
The EXCEL (Evaluation of Xience Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) trial compared outcomes in patients with unprotected left main coronary artery disease (LMCAD) treated with coronary artery bypass graft (CABG) or percutaneous coronary intervention (PCI) using everolimus-eluting stents. Whereas rates of death, stroke, and myocardial infarction were similar at 36 months, event timing and repeat revascularization rates differed by treatment group. To understand the effects of revascularization strategy from the patient's perspective, a prospective quality of life (QoL) substudy was performed alongside the EXCEL trial. Between September 2010 and March 2014, 1,905 patients with LMCAD were randomized to undergo CABG or PCI, of whom 1,788 participated in the QoL substudy. QoL was assessed at baseline and 1, 12, and 36 months using the Seattle Angina Questionnaire, the 12-Item Short Form Health Survey, the Rose Dyspnea Scale, the Patient Health Questionnaire-8, and the EQ-5D. Differences between PCI and CABG were assessed using longitudinal random-effect growth curve models. Over 36 months, both PCI and CABG were associated with significant improvements in QoL compared with baseline. At 1 month, PCI was associated with better QoL than CABG. By 12 months though, these differences were largely attenuated, and by 36 months, there were no significant QoL differences between PCI and CABG. Among selected patients with LMCAD, both PCI and CABG result in similar QoL improvement through 36 months, although a greater early benefit is seen with PCI. Taken together with the 3-year clinical results of EXCEL, these findings suggest that PCI and CABG provide similar intermediate-term outcomes for patients with LMCAD. (Evaluation of Xience Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization [EXCEL]; NCT01205776). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Schneider, M M; Balke, M; Koenen, P; Fröhlich, M; Wafaisade, A; Bouillon, B; Banerjee, M
2016-07-01
The reliability of the Rockwood classification, the gold standard for acute acromioclavicular (AC) joint separations, has not yet been tested. The purpose of this study was to investigate the reliability of visual and measured AC joint lesion grades according to the Rockwood classification. Four investigators (two shoulder specialists and two second-year residents) examined radiographs (bilateral panoramic stress and axial views) in 58 patients and graded the injury according to the Rockwood classification using the following sequence: (1) visual classification of the AC joint lesion, (2) digital measurement of the coracoclavicular distance (CCD) and the horizontal dislocation (HD) with Osirix Dicom Viewer (Pixmeo, Switzerland), (3) classification of the AC joint lesion according to the measurements and (4) repetition of (1) and (2) after repeated anonymization by an independent physician. Visual and measured Rockwood grades as well as the CCD and HD of every patient were documented, and a CC index was calculated (CCD injured/CCD healthy). All records were then used to evaluate intra- and interobserver reliability. The disagreement between visual and measured diagnosis ranged from 6.9 to 27.6 %. Interobserver reliability for visual diagnosis was good (0.72-0.74) and excellent (0.85-0.93) for measured Rockwood grades. Intraobserver reliability was good to excellent (0.67-0.93) for visual diagnosis and excellent for measured diagnosis (0.90-0.97). The correlations between measurements of the axial view varied from 0.68 to 0.98 (good to excellent) for interobserver reliability and from 0.90 to 0.97 (excellent) for intraobserver reliability. Bilateral panoramic stress and axial radiographs are reliable examinations for grading AC joint injuries according to Rockwood's classification. Clinicians of all experience levels can precisely classify AC joint lesions according to the Rockwood classification. We recommend to grade acute ACG lesions by performing a digital measurement instead of a sole visual diagnosis because of the higher intra- and interobserver reliability. Case series, Level IV.
Shieh, Frederick K.; Gunaratnam, Naresh; Mohamud, Sagal O.; Schoenfeld, Philip
2012-01-01
Background Polyethylene Glycol-3350 without electrolytes (MiraLAX®; Schering-Plough Healthcare Products Inc.) + a carbohydrate-electrolyte solution (Gatorade; PepsiCo Inc.) + bisacodyl is frequently used for bowel cleansing, although limited data quantifies its efficacy and safety. No prior studies have assessed this in a community setting or with PM-only dosing, which is still used frequently. Aim To compare the frequency of excellent/good/fair/poor bowel cleansing with PM-only dosing of MiraLAX®-Gatorade-bisacodyl vs. 4L GoLytely®. Methods This is a retrospective endoscopic database analysis of ≥ 50 year old average-risk individuals with a normal screening colonoscopy at a community hospital and ambulatory endoscopy center. Data was extracted for the last four months when 4L GoLytely® was the preferred bowel purgative and the first 4 months when 238g MiraLAX® in 64 ounces Gatorade and four 5-mg bisacodyl tablets became the preferred purgative. All patients used PM-only dosing of bowel purgative. Results 778 subjects [GoLytely® (n=395) vs. MiraLAX® + Gatorade + bisacodyl (n=383)] were identified. Patients who took the MiraLAX® bowel preparation were more likely to achieve an excellent/good bowel cleansing compared to patients taking the GoLytely® preparation (93.3% vs. 89.3%, respectively; p = 0.048). However, when only ASA Class I patients are studied, there was no difference in frequency of excellent/good bowel cleansing (91.1% vs 93.6%, respectively; p = 0.498). No serious adverse events were identified. An excellent/good bowel cleansing was strongly associated with a recommendation for repeat colonoscopy in 10 years compared to patients with a fair cleansing [OR = 28.01; 95% CI: 13.96-56.19]. Conclusions The MiraLAX® + Gatorade + bisacodyl combination produces similar rates of excellent/good bowel cleansing as compared to GoLytely® in most average-risk individuals undergoing colonoscopy for CRC screening in a community setting. PMID:23060223
Mina, Mary; Elgarhy, Lamia; Al-Saeid, Hanan; Ibrahim, Zeinab
2018-03-12
Several treatment modalities had been used for the treatment of vitiligo, but the optimal treatment has not yet been identified. To study the efficacy of microneedling with 5-flurouracil vs its efficacy with tacrolimus in the treatment of vitiligo. Twenty-five patients with vitiligo were subjected to microneedling of 2 patches of vitiligo with dermapen, then application of 5-fluorouracil to 1 patch and tacrolimus on the other patch. This procedure was repeated every 2 weeks for every patient for maximum 6 months (12 sessions). The patients were followed up for 3 months after the last session. The overall repigmentation was significantly higher in 5-fluorouracil-treated patches compared with tacrolimus. Excellent improvement occurred in 48% of 5- flurouracil-treated patches while only in 16% of tacrolimus-treated patches. In the acral parts, 40% of the patches treated with 5-fluorouracil achieved excellent improvement (repigmentation >75%), while no patch in the acral parts achieved excellent improvement with tacrolimus. However, there was significant difference between the 2 drugs,regarding inflammation, ulceration, and hyperpigmentation which occurred with 5-fluorouracil. Microneedling combined with 5-fluorouracil or tacrolimus is safe and effective treatment of vitiligo. However, 5-fluorouracil achieved a greater percentage of repigmentation than tacrolimus particularly in the acral parts. © 2018 Wiley Periodicals, Inc.
Quantitative MR Imaging of Hepatic Steatosis: Validation in Ex Vivo Human Livers
Bannas, Peter; Kramer, Harald; Hernando, Diego; Agni, Rashmi; Cunningham, Ashley M.; Mandal, Rakesh; Motosugi, Utaroh; Sharma, Samir D.; del Rio, Alejandro Munoz; Fernandez, Luis; Reeder, Scott B.
2015-01-01
Emerging magnetic resonance imaging (MRI) biomarkers of hepatic steatosis have demonstrated tremendous promise for accurate quantification of hepatic triglyceride concentration. These methods quantify the “proton density fat-fraction” (PDFF), which reflects the concentration of triglycerides in tissue. Previous in vivo studies have compared MRI-PDFF with histologic steatosis grading for assessment of hepatic steatosis. However, the correlation of MRI-PDFF with the underlying hepatic triglyceride content remained unknown. The aim of this ex vivo study was to validate the accuracy of MRI-PDFF as an imaging biomarker of hepatic steatosis. Using ex vivo human livers, we compared MRI-PDFF with magnetic resonance spectroscopy-PDFF (MRS-PDFF), biochemical triglyceride extraction and histology as three independent reference standards. A secondary aim was to compare the precision of MRI-PDFF relative to biopsy for the quantification of hepatic steatosis. MRI-PDFF was prospectively performed at 1.5T in 13 explanted human livers. We performed co-localized paired evaluation of liver fat content in all nine Couinaud segments using single-voxel MRS-PDFF (n=117), tissue wedges for biochemical triglyceride extraction (n=117), and five core biopsies performed in each segment for histologic grading (n=585). Accuracy of MRI-PDFF was assessed through linear regression with MRS-PDFF, triglyceride extraction and histology. Intra-observer agreement, inter-observer agreement and repeatability of MRI-PDFF and histologic grading were assessed through Bland-Altman analyses. MRI-PDFF showed an excellent correlation with MRS-PDFF (r=0.984; CI: 0.978–0.989) and strong correlation with histology (r=0.850; CI: 0.791–0.894) and triglyceride extraction (r=0.871; CI: 0.818–0.909). Intra-observer agreement, inter-observer agreement and repeatability showed a significantly smaller variance for MRI-PDFF than for histologic steatosis grading (all p<0.001). Conclusion MRI-PDFF is an accurate, precise and reader-independent non-invasive imaging biomarker of liver triglyceride content, capable of steatosis quantification over the entire liver. PMID:26224591
AbouShabana, N M; AbdelKader, R; Abdel-Rahman, S; Abdel-Gawad, H S; Abdel-Galil, A M
2018-05-22
The current study was conducted to investigate the effect of ExcelMOS® in enhancing the immune system of Sparus aurata broodstock and their impact on offspring health through displaying the maternal transfer of immunity. Broodstock were divided into two groups: one was injected intraperitoneally with ExcelMOS® 1 month before spawning, while the other group was used as a control (without injection). Comprehensive increase in survival rate was observed for larvae hatched from ExcelMOS®-injected broodstock than those of the control (P ≤ 0.05). Hematological analysis showed increases in leukocyte count and hematocrit percentage (P ≤ 0.05) and significant enhancement in immune assays as phagocytic, respiratory burst, lysozyme activities in ExcelMOS®-injected broodstock (P ≤ 0.05). Additionally, total immunoglobulin levels in the serum, eggs, and larvae resulted from ExcelMOS®-injected broodstock were highly significant (P ≤ 0.05) than those in the control ones. Transmission electron microscopy and semi-thin sections in posterior intestine of ExcelMOS®-injected broodstock revealed reinforcement of the epithelial barrier structure, intestinal integrity, and functionality in combination with the stimulation of innate immune system. In conclusion, immunostimulation of Sparus aurata broodstock using ExcelMOS® has improved survival of larvae and enhanced both innate and adaptive immune defense mechanisms. Further investigations are required to show the effect of ExcelMOS® on fish cultured in intensive culture systems.
Takács, Péter
2016-01-01
We compared the repeatability, reproducibility (intra- and inter-measurer similarity), separative power and subjectivity (measurer effect on results) of four morphometric methods frequently used in ichthyological research, the “traditional” caliper-based (TRA) and truss-network (TRU) distance methods and two geometric methods that compare landmark coordinates on the body (GMB) and scales (GMS). In each case, measurements were performed three times by three measurers on the same specimen of three common cyprinid species (roach Rutilus rutilus (Linnaeus, 1758), bleak Alburnus alburnus (Linnaeus, 1758) and Prussian carp Carassius gibelio (Bloch, 1782)) collected from three closely-situated sites in the Lake Balaton catchment (Hungary) in 2014. TRA measurements were made on conserved specimens using a digital caliper, while TRU, GMB and GMS measurements were undertaken on digital images of the bodies and scales. In most cases, intra-measurer repeatability was similar. While all four methods were able to differentiate the source populations, significant differences were observed in their repeatability, reproducibility and subjectivity. GMB displayed highest overall repeatability and reproducibility and was least burdened by measurer effect. While GMS showed similar repeatability to GMB when fish scales had a characteristic shape, it showed significantly lower reproducability (compared with its repeatability) for each species than the other methods. TRU showed similar repeatability as the GMS. TRA was the least applicable method as measurements were obtained from the fish itself, resulting in poor repeatability and reproducibility. Although all four methods showed some degree of subjectivity, TRA was the only method where population-level detachment was entirely overwritten by measurer effect. Based on these results, we recommend a) avoidance of aggregating different measurer’s datasets when using TRA and GMS methods; and b) use of image-based methods for morphometric surveys. Automation of the morphometric workflow would also reduce any measurer effect and eliminate measurement and data-input errors. PMID:27327896
Rovozzo, René; Korza, George; Baker, Mei W.; Li, Meng; Bhattacharyya, Anita; Barbarese, Elisa; Carson, John H.
2016-01-01
CGG repeats in the 5’UTR of Fragile X Mental Retardation 1 (FMR1) RNA mediate RNA localization and translation in granules. Large expansions of CGG repeats (> 200 repeats) in FMR1, referred to as full mutations, are associated with fragile X syndrome (FXS). Smaller expansions (55–200 repeats), referred to as premutations, are associated with fragile X tremor ataxia syndrome (FXTAS) and fragile X premature ovarian insufficiency (FXPOI). TMPyP4 is a porphyrin ring compound that destabilizes CGG repeat RNA secondary structure. Here we show that exogenous CGG repeat RNA by itself, lacking the FMRP ORF, microinjected into hippocampal neurons is localized in RNA granules and inhibits translation of ARC RNA, which is localized in the same granules. TMPyP4 rescues translation of ARC RNA in granules. We also show that in human premutation fibroblasts with endogenous CGG repeat expansions in the FMR1 gene, translation of ARC RNA is inhibited and calcium homeostasis is disrupted and both phenotypes are rescued by TMPyP4. Inhibition of granule translation by expanded CGG repeats and rescue of granule translation by TMPy4, represent potential pathogenic mechanism and therapeutic strategy, respectively, for FXTAS and FXPOI. PMID:28005950
Melters, Daniël P; Bradnam, Keith R; Young, Hugh A; Telis, Natalie; May, Michael R; Ruby, J Graham; Sebra, Robert; Peluso, Paul; Eid, John; Rank, David; Garcia, José Fernando; DeRisi, Joseph L; Smith, Timothy; Tobias, Christian; Ross-Ibarra, Jeffrey; Korf, Ian; Chan, Simon W L
2013-01-30
Centromeres are essential for chromosome segregation, yet their DNA sequences evolve rapidly. In most animals and plants that have been studied, centromeres contain megabase-scale arrays of tandem repeats. Despite their importance, very little is known about the degree to which centromere tandem repeats share common properties between different species across different phyla. We used bioinformatic methods to identify high-copy tandem repeats from 282 species using publicly available genomic sequence and our own data. Our methods are compatible with all current sequencing technologies. Long Pacific Biosciences sequence reads allowed us to find tandem repeat monomers up to 1,419 bp. We assumed that the most abundant tandem repeat is the centromere DNA, which was true for most species whose centromeres have been previously characterized, suggesting this is a general property of genomes. High-copy centromere tandem repeats were found in almost all animal and plant genomes, but repeat monomers were highly variable in sequence composition and length. Furthermore, phylogenetic analysis of sequence homology showed little evidence of sequence conservation beyond approximately 50 million years of divergence. We find that despite an overall lack of sequence conservation, centromere tandem repeats from diverse species showed similar modes of evolution. While centromere position in most eukaryotes is epigenetically determined, our results indicate that tandem repeats are highly prevalent at centromeres of both animal and plant genomes. This suggests a functional role for such repeats, perhaps in promoting concerted evolution of centromere DNA across chromosomes.
2013-01-01
Background Centromeres are essential for chromosome segregation, yet their DNA sequences evolve rapidly. In most animals and plants that have been studied, centromeres contain megabase-scale arrays of tandem repeats. Despite their importance, very little is known about the degree to which centromere tandem repeats share common properties between different species across different phyla. We used bioinformatic methods to identify high-copy tandem repeats from 282 species using publicly available genomic sequence and our own data. Results Our methods are compatible with all current sequencing technologies. Long Pacific Biosciences sequence reads allowed us to find tandem repeat monomers up to 1,419 bp. We assumed that the most abundant tandem repeat is the centromere DNA, which was true for most species whose centromeres have been previously characterized, suggesting this is a general property of genomes. High-copy centromere tandem repeats were found in almost all animal and plant genomes, but repeat monomers were highly variable in sequence composition and length. Furthermore, phylogenetic analysis of sequence homology showed little evidence of sequence conservation beyond approximately 50 million years of divergence. We find that despite an overall lack of sequence conservation, centromere tandem repeats from diverse species showed similar modes of evolution. Conclusions While centromere position in most eukaryotes is epigenetically determined, our results indicate that tandem repeats are highly prevalent at centromeres of both animal and plant genomes. This suggests a functional role for such repeats, perhaps in promoting concerted evolution of centromere DNA across chromosomes. PMID:23363705
A new family of dispersed repeats from Brassica nigra: characterization and localization.
Kapila, R; Negi, M S; This, P; Delseny, M; Srivastava, P S; Lakshmikumaran, M
1996-11-01
The 459-bp HindIII (pBN-4) and the 1732-bp Eco RI (pBNE8) fragments from the Brassica nigra genome were cloned and shown to be members of a dispersed repeat family. Of the three major diploid Brassica species, the repeat pBN-4 was found to be highly specific for the B. nigra genome. The family also hybridized to Sinapis arvensis showing that B. nigra had a closer relationship with the S. arvensis genome than with B. oleracea or B. campestris. The clone pBNE8 showed homology to a number of tRNA species indicating that this family of repeats may have originated from a tRNA sequence. The species-specific 459-bp repeat pBN-4 was localized on the B. nigra chromosomes using monosomic addition lines. In addition to the localization of pBN-4, the chromosomal distribution of two other species-specific repeats, pBN34 and pBNBH35 (reported earlier), was studied. The dispersed repeats pBN-4 and pBNBH35 were found to be present on all of the chromosomes, whereas the tandem repeat pBN34 was localized on two chromosomes.
Does it really feel the same? Changes in life satisfaction following repeated life events.
Luhmann, Maike; Eid, Michael
2009-08-01
Unemployment, divorce, and marriage are common life events for most people in Western societies. In a longitudinal study, the authors investigated how these life events affect life satisfaction when they occur repeatedly. Data came from the German Socio-Economic Panel, a large-scale representative panel study, and were analyzed using multilevel modeling. Results showed that, in general, life satisfaction decreases with repeated unemployment (sensitization). For repeated divorces, life satisfaction is higher at the second divorce than it had been at the first divorce (adaptation). Finally, life satisfaction is similar at repeated marriages. Neuroticism, extraversion, and gender accounted for interindividual differences in changes in life satisfaction. For instance, the general sensitization pattern associated with repeated unemployment was less pronounced for women. The authors also found main effects of age and the duration of the first event on general differences in life satisfaction. Finally, those with repeated events generally report lower life satisfaction than those with only one occasion of these events, even before the first event actually occurred. Findings show that repeated events can have very different effects on life satisfaction that depend on the nature of the event.
Adamietz, B; Cavallaro, A; Radkow, T; Alibek, S; Holter, W; Bautz, W A; Staatz, G
2007-08-01
To investigate the tolerance of MR examinations in children and adolescents performed in a 1.5 Tesla MR scanner with an expanded bore diameter. 163 patients, ages 4 to 25, underwent MR examinations in a 1.5 Tesla MR scanner with an open design (MAGNETOM Espree, Siemens, Erlangen, Germany), characterized by a compact length of 125 cm and an expanded 70 cm bore diameter. MR imaging of the brain was carried out in most cases (78.5 %), followed by examinations of the spinal canal (9.8 %), the extremities (9.2 %) and the neck (2.5 %). The patients were divided into four age groups and the success rate, motion artifacts and diagnostic quality of the MR examinations were assessed using a 3-grade scale. In 119 of 163 patients (73.0 %), MR examination was possible without any motion artifacts. With respect to the different age groups, 41.7 % of the 4 - 7-year-old children, 67.6 % of the 8 - 10-year-old children, 84.1 % of the 11 - 16-year-old children and 95.8 % of the patients older than 17 showed tolerance grade I without motion artifacts and excellent diagnostic image quality. In 39 of 163 children (23.9 %), the MR images showed moderate motion artifacts but had sufficient diagnostic quality. With regard to the different age groups, 52.8 % of the 4 - 7-year-old children, 26.5 % of the 8 - 10-year-old children, 15.9 % of the 11 - 16-year-old children and none of the patients older than 17 showed tolerance grade II with moderate motion artifacts and sufficient diagnostic image quality. In only 4 of 124 children < 10 years old and 1 child > 10 years old, the MR examination was not feasible and had to be repeated under sedation. Pediatric MR imaging using a 1.5 Tesla MR scanner with an open design can be conducted in children and adolescents with excellent acceptance. The failure rate of 3.0 % of cases for pediatric MR imaging is comparable to that of a conventional low-field open MR scanner.
Validity and Reliability of a Portable Balance Tracking System, BTrackS, in Older Adults.
Levy, Susan S; Thralls, Katie J; Kviatkovsky, Shiloah A
Falls are the leading cause of disability, injury, hospital admission, and injury-related death among older adults. Balance limitations have consistently been identified as predictors of falls and increased fall risk. Field measures of balance are limited by issues of subjectivity, ceiling effects, and low sensitivity to change. The gold standard for measuring balance is the force plate; however, its field use is untenable due to high cost and lack of portability. Thus, a critical need is observed for valid objective field measures of balance to accurately assess balance and identify limitations over time. The purpose of this study was to examine the concurrent validity and 3-day test-retest reliability of Balance Tracking System (BTrackS) in community-dwelling older adults. Minimal detectable change values were also calculated to reflect changes in balance beyond measurement error. Postural sway data were collected from community-dwelling older adults (N = 49, mean [SD] age = 71.3 [7.3] years) with a force plate and BTrackS in multitrial eyes open (EO) and eyes closed (EC) static balance conditions. Force sensors transmitted BTrackS data via a USB to a computer running custom software. Three approaches to concurrent validity were taken including calculation of Pearson product moment correlation coefficients, repeated-measures ANOVAs, and Bland-Altman plots. Three-day test-retest reliability of BTrackS was examined in a second sample of 47 community-dwelling older adults (mean [SD] age = 75.8 [7.7] years) using intraclass correlation coefficients and MDC values at 95% CI (MDC95) were calculated. BTrackS demonstrated good validity using Pearson product moment correlations (r > 0.90). Repeated-measures ANOVA and Bland-Altman plots indicated some BTrackS bias with center of pressure (COP) values higher than FP COP values in the EO (mean [SD] bias = 4.0 [6.8]) and EC (mean [SD] bias = 9.6 [12.3]) conditions. Test-retest reliability using intraclass correlation coefficients (ICC2.1 was excellent (0.83) and calculated MDC95 for EO (9.6 cm) and EC (19.4 cm) and suggested that postural sway changes of these amounts are meaningful. BTrackS showed some bias with values exceeding force plate values in both EO and EC conditions. Excellent test-retest reliability and resulting MDC95 values indicated that BTrackS has the potential to identify meaningful changes in balance that may warrant intervention. BTrackS is an objective measure of balance that can be used to monitor balance in community-dwelling older adults over time. It can reliably identify changes that may require further attention (eg, fall-prevention strategies, declines in physical function) and shows promise for assessing intervention efficacy in this growing segment of the population.
Metsu, Sofie; Rainger, Jacqueline K; Debacker, Kim; Bernhard, Birgitta; Rooms, Liesbeth; Grafodatskaya, Daria; Weksberg, Rosanna; Fombonne, Eric; Taylor, Martin S; Scherer, Stephen W; Kooy, R Frank; FitzPatrick, David R
2014-11-01
We report de novo occurrence of the 7p11.2 folate-sensitive fragile site FRA7A in a male with an autistic spectrum disorder (ASD) due to a CGG-repeat expansion mutation (∼450 repeats) in a 5' intron of ZNF713. This expanded allele showed hypermethylation of the adjacent CpG island with reduced ZNF713 expression observed in a proband-derived lymphoblastoid cell line (LCL). His unaffected mother carried an unmethylated premutation (85 repeats). This CGG-repeat showed length polymorphism in control samples (five to 22 repeats). In a second unrelated family, three siblings with ASD and their unaffected father were found to carry FRA7A premutations, which were partially or mosaically methylated. In one of the affected siblings, mitotic instability of the premutation was observed. ZNF713 expression in LCLs in this family was increased in three of these four premutation carriers. A firm link cannot yet be established between ASD and the repeat expansion mutation but plausible pathogenic mechanisms are discussed. © 2014 WILEY PERIODICALS, INC.
Guizard, Sébastien; Piégu, Benoît; Arensburger, Peter; Guillou, Florian; Bigot, Yves
2016-08-19
The program RepeatMasker and the database Repbase-ISB are part of the most widely used strategy for annotating repeats in animal genomes. They have been used to show that avian genomes have a lower repeat content (8-12 %) than the sequenced genomes of many vertebrate species (30-55 %). However, the efficiency of such a library-based strategies is dependent on the quality and completeness of the sequences in the database that is used. An alternative to these library based methods are methods that identify repeats de novo. These alternative methods have existed for a least a decade and may be more powerful than the library based methods. We have used an annotation strategy involving several complementary de novo tools to determine the repeat content of the model genome galGal4 (1.04 Gbp), including identifying simple sequence repeats (SSRs), tandem repeats and transposable elements (TEs). We annotated over one Gbp. of the galGal4 genome and showed that it is composed of approximately 19 % SSRs and TEs repeats. Furthermore, we estimate that the actual genome of the red jungle fowl contains about 31-35 % repeats. We find that library-based methods tend to overestimate TE diversity. These results have a major impact on the current understanding of repeats distributions throughout chromosomes in the red jungle fowl. Our results are a proof of concept of the reliability of using de novo tools to annotate repeats in large animal genomes. They have also revealed issues that will need to be resolved in order to develop gold-standard methodologies for annotating repeats in eukaryote genomes.
Rodrigues, Letícia C.; Marques, Aline P.; Barros, Paula B.; Michaelsen, Stella M.
2014-01-01
BACKGROUND: The Balance Evaluation Systems Test (BESTest) was recently created to allow the development of treatments according to the specific balance system affected in each patient. The Brazilian version of the BESTest has not been specifically tested after stroke. OBJECTIVE: To evaluate the intra- and inter-rater reliability and concurrent and convergent validity of the total score of the BESTest and BESTest sections for adults with hemiparesis after stroke. METHOD: The study included 16 subjects (61.1±7.5 years) with chronic hemiparesis (54.5±43.5 months after stroke). The BESTest was administered by two raters in the same week and one of the raters repeated the test after a one-week interval. Intraclass correlation coefficient (ICC) was calculated to assess intra- and interrater reliability. Concurrent validity with the Berg Balance Scale (BBS) and convergent validity with the Activities-specific Balance Confidence scale (ABC-Brazil) were assessed using Pearson's correlation coefficient. RESULTS: Both the BESTest total score (ICC=0.98) and the BESTest sections (ICC between 0.85 and 0.96) have excellent intrarater reliability. Interrater reliability for the total score was excellent (ICC=0.93) and, for the sections, it ranged between 0.71 and 0.94. The correlation coefficient between the BESTest and the BBS and ABC-Brazil were 0.78 and 0.59, respectively. CONCLUSIONS: The Brazilian version of the BESTest demonstrated adequate reliability when measured by sections and could identify what balance system was affected in patients after stroke. Concurrent validity was excellent with the BBS total score and good to excellent with the sections. The total scores but not the sections present adequate convergent validity with the ABC-Brazil. However, other psychometric properties should be further investigated. PMID:25003281
Ara, Mirian; Ferreras, Antonio; Pajarin, Ana B; Calvo, Pilar; Figus, Michele; Frezzotti, Paolo
2015-01-01
To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.
Greguš, Michal; Foret, František; Kubáň, Petr
2015-02-01
The analysis of ionic content of exhaled breath condensate (EBC) from one single breath by CE with C(4) D is demonstrated for the first time. A miniature sampler made from a 2-mL syringe and an aluminum cooling cylinder for collection of EBC was developed. Various parameters of the sampler that influence its collection efficiency, repeatability, and effect of respiratory patterns were studied in detail. Efficient procedures for the cleanup of the miniature sampler were also developed and resulted in significant improvement of sampling repeatability. Analysis of EBC was performed by CE-C(4) D in a 60 mM MES/l-histidine BGE with 30 μM CTAB and 2 mM 18-crown-6 at pH 6 and excellent repeatability of migration times (RSD < 1.3% (n = 7)) and peak areas (RSD < 7% (n = 7)) of 12 inorganic anions, cations, and organic acids was obtained. It has been shown that the breathing pattern has a significant impact on the concentration of the analytes in the collected EBC. As the ventilatory pattern can be easily controlled during single exhalation, the developed collection system and method provides a highly reproducible and fast way of collecting EBC with applicability in point-of-care diagnostics. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Development of Pineapple Microsatellite Markers and Germplasm Genetic Diversity Analysis
Tong, Helin; Chen, You; Wang, Jingyi; Chen, Yeyuan; Sun, Guangming; He, Junhu; Wu, Yaoting
2013-01-01
Two methods were used to develop pineapple microsatellite markers. Genomic library-based SSR development: using selectively amplified microsatellite assay, 86 sequences were generated from pineapple genomic library. 91 (96.8%) of the 94 Simple Sequence Repeat (SSR) loci were dinucleotide repeats (39 AC/GT repeats and 52 GA/TC repeats, accounting for 42.9% and 57.1%, resp.), and the other three were mononucleotide repeats. Thirty-six pairs of SSR primers were designed; 24 of them generated clear bands of expected sizes, and 13 of them showed polymorphism. EST-based SSR development: 5659 pineapple EST sequences obtained from NCBI were analyzed; among 1397 nonredundant EST sequences, 843 were found containing 1110 SSR loci (217 of them contained more than one SSR locus). Frequency of SSRs in pineapple EST sequences is 1SSR/3.73 kb, and 44 types were found. Mononucleotide, dinucleotide, and trinucleotide repeats dominate, accounting for 95.6% in total. AG/CT and AGC/GCT were the dominant type of dinucleotide and trinucleotide repeats, accounting for 83.5% and 24.1%, respectively. Thirty pairs of primers were designed for each of randomly selected 30 sequences; 26 of them generated clear and reproducible bands, and 22 of them showed polymorphism. Eighteen pairs of primers obtained by the one or the other of the two methods above that showed polymorphism were selected to carry out germplasm genetic diversity analysis for 48 breeds of pineapple; similarity coefficients of these breeds were between 0.59 and 1.00, and they can be divided into four groups accordingly. Amplification products of five SSR markers were extracted and sequenced, corresponding repeat loci were found and locus mutations are mainly in copy number of repeats and base mutations in the flanking region. PMID:24024187
Photoresponse in La0.9Hf0.1MnO3/0.05wt%Nb-doped SrTiO3 heteroepitaxial junctions
NASA Astrophysics Data System (ADS)
Qi, Yaping; Ni, Hao; Zheng, Ming; Zeng, Jiali; Jiang, Yucheng; Gao, Ju
2018-05-01
Excellent photo detectors need to have the rapid response and good repeatability from the requirement of industrial applications. In this paper, transport behavior and opto-response of heterostructures made with La0.9Hf0.1MnO3 and 0.05wt%Nb-doped SrTiO3 were investigated. The heterojunctions exhibited an excellent rectifying feature with very low leakage in a broad temperature region (from 40 to 300 K). These thin films presented persistent and stable photovoltages upon light illumination. Rapid shift between small and large voltages corresponding to "light OFF" and "light ON" states, respectively, was observed, demonstrating reliable photo detection behavior. A semiconductor laser with a wavelength of 650 nm was used as the light source. It is also noted that the observed photovoltages are strongly determined by light intensity. The injection of photoexcited charge carriers (electrons) could be responsible for the appearance of the observed opto-response. Such manipulative features by light irradiation exhibit great potential for light detectors for visible light.
Preparation of β-cyclodextrin entrapped graphite composite for sensitive detection of dopamine.
Palanisamy, Selvakumar; Sakthinathan, S; Chen, Shen-Ming; Thirumalraj, Balamurugan; Wu, Tsung-Han; Lou, Bih-Show; Liu, Xiaoheng
2016-01-01
A simple dopamine (DA) electrochemical sensor was developed based on a screen-printed carbon electrode (SPCE) modified with β-cyclodextrin entrapped graphite (GR/β-CD) composite for the first time. The polar hydroxyl groups on the β-CD rims interact with polar groups of edges of GR sheets resulting into the high dispersion ability of GR in β-CD solution. The GR/β-CD modified electrode exhibited a higher electrochemical response to DA with a lower oxidation potential (0.224V) than that of bare/β-CD (0.38V) and GR (0.525V) modified SPCEs, revealing an excellent electro-oxidation behavior of GR/β-CD composite toward DA. Under optimum conditions, the fabricated sensor detects the DA in the linear concentration range from 0.1 to 58.5μM with a limit of detection of 0.011μM and the sensitivity of 1.27±0.02μAμM(-1)cm(-2). The fabricated sensor also exhibits the excellent repeatability, practicality, reproducibility, storage stability along with acceptable selectivity. Copyright © 2015 Elsevier Ltd. All rights reserved.
Zhang, Jingyuan Linda; Lagoudakis, Konstantinos G.; Tzeng, Yan -Kai; ...
2017-10-23
Arrays of identical and individually addressable qubits lay the foundation for the creation of scalable quantum hardware such as quantum processors and repeaters. Silicon-vacancy (SiV) centers in diamond offer excellent physical properties such as low inhomogeneous broadening, fast photon emission, and a large Debye–Waller factor. The possibility for all-optical ultrafast manipulation and techniques to extend the spin coherence times makes them promising candidates for qubits. Here, we have developed arrays of nanopillars containing single (SiV) centers with high yield, and we demonstrate ultrafast all-optical complete coherent control of the excited state population of a single SiV center at the opticalmore » transition frequency. The high quality of the chemical vapor deposition (CVD) grown SiV centers provides excellent spectral stability, which allows us to coherently manipulate and quasi-resonantly read out the excited state population of individual SiV centers on picosecond timescales using ultrafast optical pulses. Furthermore, this work opens new opportunities to create a scalable on-chip diamond platform for quantum information processing and scalable nanophotonics applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jingyuan Linda; Lagoudakis, Konstantinos G.; Tzeng, Yan -Kai
Arrays of identical and individually addressable qubits lay the foundation for the creation of scalable quantum hardware such as quantum processors and repeaters. Silicon-vacancy (SiV) centers in diamond offer excellent physical properties such as low inhomogeneous broadening, fast photon emission, and a large Debye–Waller factor. The possibility for all-optical ultrafast manipulation and techniques to extend the spin coherence times makes them promising candidates for qubits. Here, we have developed arrays of nanopillars containing single (SiV) centers with high yield, and we demonstrate ultrafast all-optical complete coherent control of the excited state population of a single SiV center at the opticalmore » transition frequency. The high quality of the chemical vapor deposition (CVD) grown SiV centers provides excellent spectral stability, which allows us to coherently manipulate and quasi-resonantly read out the excited state population of individual SiV centers on picosecond timescales using ultrafast optical pulses. Furthermore, this work opens new opportunities to create a scalable on-chip diamond platform for quantum information processing and scalable nanophotonics applications.« less
Assessment of programs in space biology and medicine
NASA Technical Reports Server (NTRS)
1991-01-01
Over the past 30 or more years, the National Research Council Space Studies Board and its various committees have published hundreds of recommendations concerning life sciences research. Several particularly noteworthy themes appear consistently: (1) Balance - the need for a well-balanced research program in terms of ground versus flight, basic versus clinical, and internal versus extramural; (2) Excellence - because of the extremely limited number of flight opportunities (as well as their associated relative costs), the need for absolute excellence in the research that is conducted, in terms of topic, protocol, and investigator, and (3) Facilities - the single most important facility for life sciences research in space, an on-board, variable force centrifuge. In this first assessment report, the Committee on Space Biology and Medicine emphasizes that these long-standing themes remain as essential today as when first articulated. On the brink of the twenty-first century, the nation is contemplating the goal of human space exploration; consequently, the themes bear repeating. Each is a critical component of what will be necessary to successfully achieve such a goal.
Service Academy 2006 Gender Relations Survey: Tabulations of Responses
2006-07-01
with you without your consent .....56 c. Someone repeatedly showed you pornographic materials, even after you asked him/her not to...harassment, sexual assault, or neither? Assume the behaviors were offensive and harmful to you. c. Someone repeatedly showed you pornographic materials
NASA Astrophysics Data System (ADS)
Will, R. A.; Balch, R. S.
2015-12-01
The Southwest Partnership on Carbon Sequestration is performing seismic based characterization and monitoring activities at an active CO2 EOR project at Farnsworth Field, Texas. CO2 is anthropogenically sourced from a fertilizer and an ethanol plant. The field has 13 CO2 injectors and has sequestered 302,982 metric tonnes of CO2 since October 2013. The field site provides an excellent laboratory for testing a range of monitoring technologies in an operating CO2 flood since planned development is sequential and allows for multiple opportunities to record zero CO2 baseline data, mid-flood data, and fully flooded data. The project is comparing and contrasting several scales of seismic technologies in order to determine best practices for large scale commercial sequestration projects. Characterization efforts include an 85 km2 3D surface seismic survey, baseline and repeat 3D VSP surveys centered on injection wells, cross-well tomography baseline and repeat surveys between injector/producer pairs, and a borehole passive seismic array to monitor induced seismicity. All surveys have contributed to detailed geologic models which were then used for fluid flow and risk assessment simulations. 3D VSP and cross-well data with repeat surveys have allowed for direct comparisons of the reservoir prior to CO2 injection and at eight months into injection, with a goal of imaging the CO2 plume as it moves away from injection wells. Additional repeat surveys at regular intervals will continue to refine the plume. The goal of this work is to demonstrate seismic based technologies to monitor CO2 sequestration projects, and to contribute to best practices manuals for commercial scale CO2 sequestration projects. In this talk the seismic plan will be outlined, progress towards goals enumerated, and preliminary results from baseline and repeat seismic data will be discussed. Funding for this project is provided by the U.S. Department of Energy under Award No. DE-FC26-05NT42591.
Loftus, Russell; Nugent, Zoann; Graff, Lesley A; Schumacher, Frederick; Bernstein, Charles N; Singh, Harminder
2013-01-01
Patient experiences with endoscopy visits within a large central Canadian health region were evaluated to determine the relationship between the visit experience and the patients' willingness to return for future endoscopy, and to identify the factors associated with patients' willingness to return. A self-report survey was distributed to 1200 consecutive individuals undergoing an upper and⁄or lower gastrointestinal endoscopy at any one of the six hospital-based endoscopy facilities in the region. The Spearman correlation coefficient was used to assess the association between the patients' overall rating of the visits and willingness to return for repeat procedures under similar medical circumstances. Logistic regression analyses were performed to identify the factors associated with willingness to return for repeat endoscopy and overall satisfaction (rating) of the visit. A total of 529 (44%) individuals returned the questionnaire, with 45% rating the visit as excellent and 56% indicating they were extremely likely to return for repeat endoscopy. There was a low moderate correlation between overall rating of the visit and patients' willingness to return for repeat endoscopy (r=0.30). The factors independently associated with patient willingness to return for repeat endoscopy included perceived technical skills of the endoscopists (OR 2.7 [95% CI 1.3 to 5.5]), absence of pain during the procedure (OR 2.2 [95% CI 1.3 to 3.6]) and history of previous endoscopy (OR 2.4 [95% CI 1.4 to 4.1]). In contrast, the independent factors associated with the overall rating of the visit included information provided pre- and postprocedure, wait time before and on the day of the visit, and the physical environment. To facilitate patient return for needed endoscopy, it is important to assess patients' willingness to return because positive behavioural intent is not simply a function of satisfaction with the visit.
Validation of OCT-based Crystalline Lens Thickness Measurements in Children
Lehman, Bret M.; Berntsen, David A.; Bailey, Melissa D.; Zadnik, Karla
2010-01-01
Purpose To evaluate the validity and repeatability of crystalline lens thickness measurements obtained by anterior segment optical coherence tomography. Methods Forty-seven normal children (mean age, 11.06 ± 2.30 years) had their crystalline lens thickness measured with the Visante anterior segment optical coherence tomography (OCT) (Carl Zeiss Meditec, Dublin, CA) and with conventional corneal touch A-scan ultransonography (ultrasound) (Humphrey 820). The subjects’ right corneas were anesthetized, and their right eyes were cyclopleged. Five ultrasound measurements were recorded per eye, and three Visante OCT measurements were recorded per eye. Thirty-eight subjects had measurements at a second visit where three additional Visante OCT measurements were recorded. Results The mean of the differences between the Visante OCT and ultrasound was −0.045 mm (p = 0.017) with 95% limits of agreement from −0.29 to 0.20 mm indicating that the measurement of crystalline lens thickness was slightly thinner with the Visante OCT. When validity was assessed using only Visante OCT images that contained the corneal reflex, the mean of the differences was 0.019 mm (p = 0.11) with 95% limits of agreement from −0.091 to 0.13 mm. For the repeatability of the Visante OCT, the mean of the differences between visit one and visit two was −0.008 mm (p = 0.25) with 95% limits of agreement from −0.088 to 0.072 mm. Repeatability improved when reassessed using only images that contain the corneal reflex; the mean of the differences was −0.0001 mm (p = 0.97) with 95% limits of agreement from −0.030 to 0.030 mm. Conclusion The Visante OCT is a non-contact instrument that is simple to use, and it provides valid crystalline lens thickness measurements with excellent repeatability. Validity and repeatability are optimized when the Visante OCT images contain the corneal reflex and a consistent corneal index refraction is applied to the entire image. PMID:19182701
Role of memory errors in quantum repeaters
NASA Astrophysics Data System (ADS)
Hartmann, L.; Kraus, B.; Briegel, H.-J.; Dür, W.
2007-03-01
We investigate the influence of memory errors in the quantum repeater scheme for long-range quantum communication. We show that the communication distance is limited in standard operation mode due to memory errors resulting from unavoidable waiting times for classical signals. We show how to overcome these limitations by (i) improving local memory and (ii) introducing two operational modes of the quantum repeater. In both operational modes, the repeater is run blindly, i.e., without waiting for classical signals to arrive. In the first scheme, entanglement purification protocols based on one-way classical communication are used allowing to communicate over arbitrary distances. However, the error thresholds for noise in local control operations are very stringent. The second scheme makes use of entanglement purification protocols with two-way classical communication and inherits the favorable error thresholds of the repeater run in standard mode. One can increase the possible communication distance by an order of magnitude with reasonable overhead in physical resources. We outline the architecture of a quantum repeater that can possibly ensure intercontinental quantum communication.
RGO-coated elastic fibres as wearable strain sensors for full-scale detection of human motions
NASA Astrophysics Data System (ADS)
Mi, Qing; Wang, Qi; Zang, Siyao; Mao, Guoming; Zhang, Jinnan; Ren, Xiaomin
2018-01-01
In this study, we chose highly-elastic fabric fibres as the functional carrier and then simply coated the fibres with reduced graphene oxide (rGO) using plasma treatment, dip coating and hydrothermal reduction steps, finally making a wearable strain sensor. As a result, the full-scale detection of human motions, ranging from bending joints to the pulse beat, has been achieved by these sensors. Moreover, high sensitivity, good stability and excellent repeatability were realized. The good sensing performances and economical fabrication process of this wearable strain sensor have strengthened our confidence in practical applications in smart clothing, smart fabrics, healthcare, and entertainment fields.
Joint seismic-infrasonic processing of recordings from a repeating source of atmospheric explosions.
Gibbons, Steven J; Ringdal, Frode; Kvaerna, Tormod
2007-11-01
A database has been established of seismic and infrasonic recordings from more than 100 well-constrained surface explosions, conducted by the Finnish military to destroy old ammunition. The recorded seismic signals are essentially identical and indicate that the variation in source location and magnitude is negligible. In contrast, the infrasonic arrivals on both seismic and infrasound sensors exhibit significant variation both with regard to the number of detected phases, phase travel times, and phase amplitudes, which would be attributable to atmospheric factors. This data set provides an excellent database for studies in sound propagation, infrasound array detection, and direction estimation.
Injectable Self-Healing Hydrogel with Antimicrobial and Antifouling Properties.
Li, Lin; Yan, Bin; Yang, Jingqi; Huang, Weijuan; Chen, Lingyun; Zeng, Hongbo
2017-03-22
Microbial adhesion, biofilm formation and associated microbial infection are common challenges faced by implanted biomaterials (e.g., hydrogels) in bioengineering applications. In this work, an injectable self-healing hydrogel with antimicrobial and antifouling properties was prepared through self-assembly of an ABA triblock copolymer employing catechol functionalized polyethylene glycol (PEG) as A block and poly{[2-(methacryloyloxy)-ethyl] trimethylammonium iodide}(PMETA) as B block. This hydrogel exhibits excellent thermosensitivity, and can effectively inhibit the growth of E. coli (>99.8% killing efficiency) and prevent cell attachment. It can also heal autonomously from repeated damage, through mussel-inspired catechol-mediated hydrogen bonding and aromatic interactions, exhibiting great potential in bioengineering applications.
Novel fiber optic immunosensor instrument
NASA Astrophysics Data System (ADS)
Wang, Zhiyu; Huang, Wenling; Tang, Lei; Zhou, Bo; Li, Yugi; He, Jun
1996-09-01
It has developed and performed a novel fiberoptic immunosensor instrument with operating wavelength 400 - 760 nm and repeatability cv equals 0.27%. The instrument has many excellent features such as simplified operation, faster testing time, higher sensitivity and economic cost. It has completely eliminated recovery period which traditional immunosensor owned due to use separative sensor structure. It can widely apply to test for bacteria, virus, hormone, parasite and cancer protein in clinical examination. The instrument has operated in laboratory and relevant medicine units and successfully tested monoclonal rat-anti-human of 413 cases in clinic and prepared with existing ELISA method, the coincidence probability reached 94 to 100%.
Ratiometric near infrared luminescent thermometer based on lanthanide metal-organic frameworks
NASA Astrophysics Data System (ADS)
Yue, Dan; Zhang, Jun; Zhao, Dian; Lian, Xiusheng; Cui, Yuanjing; Yang, Yu; Qian, Guodong
2016-09-01
A near infrared luminescent MOFs thermometer (Nd0.676Yb0.324BTC) was prepared via a simple solvothermal method using Ln3+ (Ln=Nd, Yb) ions and 1, 3, 5-benznenetricarboxylic acid (H3BTC), and characterized by PXRD, TGA, ICP, and photoluminescence (PL) spectrum. These results indicate that the Nd0.676Yb0.324BTC displays high relative sensitivity and excellent repeatability in the physiological temperature range (288-323 K), and the maximum relative sensitivity is determined to be 1.187% K-1 at 323 K. These NIR luminescent MOFs may have potential applications in physiological temperature sensing.
Cardiac asystole following cannabis (marijuana) usage--additional mechanism for sudden death?
Menahem, Samuel
2013-12-10
A 21 year old university student previously operated during infancy for an unobstructed total anomalous pulmonary venous drainage with an excellent result, was noted on a routine follow up 24 h Holter monitor to have multiple pauses related to cardiac asystole, the longest lasting 5.8 s and temporally related to marijuana inhalation. A repeat Holter was normal following a two week cessation of marijuana usage and again when carried out 3 months later. The documented periods of asystole may be a precursor of sudden death seen in addicts even without evidence of ischaemic heart disease. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Highly sensitive heavy metal ion detection using AlQ3 microwire functionalized QCM
NASA Astrophysics Data System (ADS)
Can, Nursel; Aǧar, Meltem; Altındal, Ahmet
2016-03-01
Tris(8-hydroxyquinoline) aluminum (Alq3) microwires was successfully synthesized for the fabrication of Alq3 microwires-coated QCM sensors to detect the heavy metal ions in aqueous solution. AT-cut quartz crystal microbalance (QCM) of 10 MHz fundamental resonance frequency having gold electrodes were used as transducers. Typical measuring cycle consisted of repeated flow of target measurands through the flow cell and subsequent washing to return the baseline. The QCM results indicated that the Alq3 microwires exhibit excellent sensitivity, stability and short response-recovery time, which are much attractive for the development of portable and highly sensitive heavy metal ion sensors in water samples.
Du, Chixin; Shen, Meixiao; Li, Ming; Zhu, Dexi; Wang, Michael R.; Wang, Jianhua
2012-01-01
Purpose To measure by ultra-long scan depth optical coherence tomography (UL-OCT) dimensional changes in the anterior segment of human eyes during accommodation. Design Evaluation of diagnostic test or technology. Participants Forty-one right eyes of healthy subjects with a mean age of 34 years (range, 22–41 years) and a mean refraction of −2.5±2.6 diopters (D) were imaged in two repeated measurements at minimal and maximal accommodation. Methods A specially adapted designed UL-OCT instrument was used to image from the front surface of the cornea to the back surface of the crystalline lens. Custom software corrected the optical distortion of the images and yielded the biometric measurements. The coefficient of repeatability (COR) and the intraclass correlation coefficient (ICC) were calculated to evaluate the repeatability and reliability. Main Outcome Measures Anterior segment parameters and associated repeatability and reliability upon accommodation. The dimensional results included central corneal thickness (CCT), anterior chamber depth and width (ACD, ACW), pupil diameter (PD), lens thickness (LT), anterior segment length (ASL=ACD+LT), lens central position (LCP=ACD+1/2LT) and horizontal radii of the lens anterior and posterior surface curvatures (LAC, LPC). Results Repeated measurements of each variable within each accommodative state did not differ significantly (P>0.05). The CORs and ICCs for CCT, ACW, ACD, LT, LCP, and ASL were excellent (1.2% to 3.59% and 0.998 to 0.877, respectively). They were higher for PD (18.90% to 21.63% and 0.880 to 0.874, respectively), and moderate for LAC and LPC (34.86% to 42.72% and 0.669 to 0.251, respectively) in the two accommodative states. Compared to minimal accommodation, PD, ACD, LAC, LPC, and LCP decreased and LT and ASL increased significantly at maximal accommodation (P<0.05), while CCT and ACW did not change (P>0.05). Conclusions UL-OCT measured changes in anterior segment dimensions during accommodation with good repeatability and reliability. During accommodation, the back surface of the lens became steeper as the lens moved forward. PMID:22902211
Jiao, Yunlong; Li, Chuanzong; Wu, Sizhu; Hu, Yanlei; Li, Jiawen; Yang, Liang; Wu, Dong; Chu, Jiaru
2018-05-16
We present here a kind of novel multiscale TiO 2 square micropillar arrays on titanium sheets through vertically crossed scanning of femtosecond laser. This multiscale micro-/nanostructure is ascribed to the combination of laser ablation/shock compression/debris self-deposition, which shows superaerophobicity in water with a very small sliding angle. The laser-induced sample displays switchable bubble wettability in water via heating in a dark environment and ultraviolet (UV) irradiation in alcohol. After heating in a dark environment (0.5 h), the ablated titanium surface shows superaerophilicity in water with a bubble contact angle (BCA) of ∼4°, which has a great ability of capturing bubbles in water. After UV irradiation in alcohol (1 h), the sample recovered its superaerophobicity in water and the BCA turns into 156°. The mechanism of reversible switching is believed as the chemical conversion between Ti-OH and Ti-O. It is worth noting that our proposed switching strategy is time-saving and the switch wetting cycle costs only 1.5 h. Then we repeat five switching cycles on the reversibility and the method shows excellent reproducibility and stability. Moreover, laser-induced samples with different scanning spacing (50-120 μm) are fabricated and all of them show switchable underwater bubble wettability via the above tunable methods. Finally, we fabricate hybrid-patterned microstructures to show different patterned bubbles in water on the heated samples. We believe the original works will provide some new insights to researchers in bubble manipulation and gas collection fields.
A study of the Huntington's disease associated trinucleotide repeat in the Scottish population.
Barron, L H; Warner, J P; Porteous, M; Holloway, S; Simpson, S; Davidson, R; Brock, D J
1993-01-01
Accurate measurements of a specific CAG repeat sequence in the Huntington's disease (HD) gene in 337 HD patients and 229 normal controls from the Scottish population showed a range from 35 to 62 repeats in affected subjects and eight to 33 in normal subjects. A link between early onset of symptoms and very high repeat number was seen. For HD patients with the most common affected allele sizes (39 to 42 repeats) absolute repeat size was a poor index for the age at onset of symptoms. There was variability in the transmitted repeat size for both sexes in the HD size range. We observed a significant increase of repeat size for paternal transmission of the disease and greater instability for paternally transmitted CAG repeats in the HD size range. Images PMID:8133495
ACCA phosphopeptide recognition by the BRCT repeats of BRCA1.
Ray, Hind; Moreau, Karen; Dizin, Eva; Callebaut, Isabelle; Venezia, Nicole Dalla
2006-06-16
The tumour suppressor gene BRCA1 encodes a 220 kDa protein that participates in multiple cellular processes. The BRCA1 protein contains a tandem of two BRCT repeats at its carboxy-terminal region. The majority of disease-associated BRCA1 mutations affect this region and provide to the BRCT repeats a central role in the BRCA1 tumour suppressor function. The BRCT repeats have been shown to mediate phospho-dependant protein-protein interactions. They recognize phosphorylated peptides using a recognition groove that spans both BRCT repeats. We previously identified an interaction between the tandem of BRCA1 BRCT repeats and ACCA, which was disrupted by germ line BRCA1 mutations that affect the BRCT repeats. We recently showed that BRCA1 modulates ACCA activity through its phospho-dependent binding to ACCA. To delineate the region of ACCA that is crucial for the regulation of its activity by BRCA1, we searched for potential phosphorylation sites in the ACCA sequence that might be recognized by the BRCA1 BRCT repeats. Using sequence analysis and structure modelling, we proposed the Ser1263 residue as the most favourable candidate among six residues, for recognition by the BRCA1 BRCT repeats. Using experimental approaches, such as GST pull-down assay with Bosc cells, we clearly showed that phosphorylation of only Ser1263 was essential for the interaction of ACCA with the BRCT repeats. We finally demonstrated by immunoprecipitation of ACCA in cells, that the whole BRCA1 protein interacts with ACCA when phosphorylated on Ser1263.
Stability of Tandem Repeats in the Drosophila Melanogaster HSR-Omega Nuclear RNA
Hogan, N. C.; Slot, F.; Traverse, K. L.; Garbe, J. C.; Bendena, W. G.; Pardue, M. L.
1995-01-01
The Drosophila melanogaster Hsr-omega locus produces a nuclear RNA containing >5 kb of tandem repeat sequences. These repeats are unique to Hsr-omega and show concerted evolution similar to that seen with classical satellite DNAs. In D. melanogaster the monomer is ~280 bp. Sequences of 191/2 monomers differ by 8 +/- 5% (mean +/- SD), when all pairwise comparisons are considered. Differences are single nucleotide substitutions and 1-3 nucleotide deletions/insertions. Changes appear to be randomly distributed over the repeat unit. Outer repeats do not show the decrease in monomer homogeneity that might be expected if homogeneity is maintained by recombination. However, just outside the last complete repeat at each end, there are a few fragments of sequence similar to the monomer. The sequences in these flanking regions are not those predicted for sequences decaying in the absence of recombination. Instead, the fragmentation of the sequence homology suggests that flanking regions have undergone more severe disruptions, possibly during an insertion or amplification event. Hsr-omega alleles differing in the number of repeats are detected and appear to be stable over a few thousand generations; however, both increases and decreases in repeat numbers have been observed. The new alleles appear to be as stable as their predecessors. No alleles of less than ~5 kb nor more than ~16 kb of repeats were seen in any stocks examined. The evidence that there is a limit on the minimum number of repeats is consistent with the suggestion that these repeats are important in the function of the unusual Hsr-omega nuclear RNA. PMID:7540581
Next generation dilatometer for highest accuracy thermal expansion measurement of ZERODUR®
NASA Astrophysics Data System (ADS)
Jedamzik, Ralf; Engel, Axel; Kunisch, Clemens; Westenberger, Gerhard; Fischer, Peter; Westerhoff, Thomas
2015-09-01
In the recent years, the ever tighter tolerance for the Coefficient of thermal expansion (CTE) of IC Lithography component materials is requesting significant progress in the metrology accuracy to determine this property as requested. ZERODUR® is known for its extremely low CTE between 0°C to 50°C. The current measurement of the thermal expansion coefficient is done using push rod dilatometer measurement systems developed at SCHOTT. In recent years measurements have been published showing the excellent CTE homogeneity of ZERODUR® in the one-digit ppb/K range using these systems. The verifiable homogeneity was limited by the CTE(0°C, 50°C) measurement repeatability in the range of ± 1.2 ppb/K of the current improved push rod dilatometer setup using an optical interferometer as detector instead of an inductive coil. With ZERODUR® TAILORED, SCHOTT introduced a low thermal expansion material grade that can be adapted to individual customer application temperature profiles. The basis for this product is a model that has been developed in 2010 for better understanding of the thermal expansion behavior under given temperature versus time conditions. The CTE behavior predicted by the model has proven to be in very good alignment with the data determined in the thermal expansions measurements. The measurements to determine the data feeding the model require a dilatometer setup with excellent stability and accuracy for long measurement times of several days. In the past few years SCHOTT spent a lot of effort to drive a dilatometer measurement technology based on the push rod setup to its limit, to fulfill the continuously demand for higher CTE accuracy and deeper material knowledge of ZERODUR®. This paper reports on the status of the dilatometer technology development at SCHOTT.
Jasmine, Farzana; Shinkle, Justin; Sabarinathan, Mekala; Ahsan, Habibul; Pierce, Brandon L; Kibriya, Muhammad G
2018-03-12
Relative telomere length (RTL) is a potential biomarker of aging and risk for chronic disease. Previously, we developed a probe-based RTL assay on Luminex platform, where probes for Telomere (T) and reference gene (R) for a given DNA sample were tested in a single well. Here, we describe a method of pooling multiple samples in one well to increase the throughput and cost-effectiveness. We used four different microbeads for the same T-probe and four different microbeads for the same R-probe. Each pair of probe sets were hybridized to DNA in separate plates and then pooled in a single plate for all the subsequent steps. We used DNA samples from 60 independent individuals and repeated in multiple batches to test the precision. The precision was good to excellent with Intraclass correlation coefficient (ICC) of 0.908 (95% CI 0.856-0.942). More than 67% of the variation in the RTL could be explained by sample-to-sample variation; less than 0.1% variation was due to batch-to-batch variation and 0.3% variation was explained by bead-to-bead variation. We increased the throughput of RTL Luminex assay from 60 to 240 samples per run. The new assay was validated against the original Luminex assay without pooling (r = 0.79, P = 1.44 × 10 -15 ). In an independent set of samples (n = 550), the new assay showed a negative correlation of RTL with age (r = -0.41), a result providing external validation for the method. We describe a novel high throughput pooled-sample multiplex Luminex assay for RTL with good to excellent precision suitable for large-scale studies. © 2018 Wiley Periodicals, Inc.
Validity and Reliability Study of Bahasa Malaysia Version of Voice Handicap Index-10.
Ong, Fei Ming; Husna Nik Hassan, Nik Fariza; Azman, Mawaddah; Sani, Abdullah; Mat Baki, Marina
2018-05-21
This study aimed to determine the validity and reliability of Bahasa Malaysia version of Voice Handicap Index-10 (mVHI-10). This cross-sectional study was carried out in the Otorhinolaryngology, Head and Neck Surgery Department of Universiti Kebangsaan Malaysia Medical Centre (UKMMC) from June 2015 to May 2016. The mVHI-10 was produced following a rigorous forward and backward translation. One hundred participants, including 50 healthy volunteers (17 male, 33 female) and 50 patients with voice disorders (26 male, 24 female), were recruited to complete the mVHI-10 before flexible laryngoscopic examinations and acoustic analysis. The mVHI-10 was repeated in 2 weeks via telephone interview or clinic visit. Its reliability and validity were assessed using interclass correlation. The test-retest reliability for total mVHI-10 and each item score was high, with the Cronbach alpha of >0.90. The total mVHI-10 score and domain scores were significantly higher (P < 0.001) in the pathology groups (20.92 ± 8.74) than healthy volunteers (1.54 ± 1.97), depicting excellent discriminant validity. The Kaiser-Meyer-Olkin measure was 0.92, which depicted excellent construct validity. There was a significant positive correlation between the mVHI-10 score and jitter and shimmer result (P < 0.001). The present study showed good reliability and validity of the mVHI-10 when applied to both healthy volunteers and patients with voice disorders. We recommend the use of the mVHI-10 in daily clinical practice among Bahasa Malaysia-speaking population. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Urrutia, Julio; Besa, Pablo; Campos, Mauricio; Cikutovic, Pablo; Cabezon, Mario; Molina, Marcelo; Cruz, Juan Pablo
2016-09-01
Grading inter-vertebral disc degeneration (IDD) is important in the evaluation of many degenerative conditions, including patients with low back pain. Magnetic resonance imaging (MRI) is considered the best imaging instrument to evaluate IDD. The Pfirrmann classification is commonly used to grade IDD; the authors describing this classification showed an adequate agreement using it; however, there has been a paucity of independent agreement studies using this grading system. The aim of this study was to perform an independent inter- and intra-observer agreement study using the Pfirrmann classification. T2-weighted sagittal images of 79 patients consecutively studied with lumbar spine MRI were classified using the Pfirrmann grading system by six evaluators (three spine surgeons and three radiologists). After a 6-week interval, the 79 cases were presented to the same evaluators in a random sequence for repeat evaluation. The intra-class correlation coefficient (ICC) and the weighted kappa (wκ) were used to determine the inter- and intra-observer agreement. The inter-observer agreement was excellent, with an ICC = 0.94 (0.93-0.95) and wκ = 0.83 (0.74-0.91). There were no differences between spine surgeons and radiologists. Likewise, there were no differences in agreement evaluating the different lumbar discs. Most differences among observers were only of one grade. Intra-observer agreement was also excellent with ICC = 0.86 (0.83-0.89) and wκ = 0.89 (0.85-0.93). In this independent study, the Pfirrmann classification demonstrated an adequate agreement among different observers and by the same observer on separate occasions. Furthermore, it allows communication between radiologists and spine surgeons.
Ejaz, Ammara; Jeon, Seungwon
2018-06-05
Pico sized Stannous oxide particles (SnO PPs) were synthesized in an ethanol-water solvent system on the surface of nitrogen doped graphene oxide (GO). The highly conductive support was a combination of dual interactions between 4-aminomethylbenzylamine (AMBA) and GO. The oppositely positioned -NH 2 linkers of the AMBA were covalently incorporated into the GO matrix through condensation reaction followed by the strong π - π stacking interactions between aromatic rings of AMBA and GO. The change in the local chemical environment of GO via dual interactions provided a suitable atmosphere for the growth and dispersion of SnO PPs on GO-AMBA surface. The possible mechanism for the formation of SnO in an ethanol-water solvent system was evaluated. Furthermore, a light was shed on the factors responsible for the pico size of SnO particles synthesis along with its phenomenal distribution on the GO-AMBA surface. The catalyst containing SnO PPs was deployed as a biosensor for the detection of ascorbic acid (AA) for the very first time. A very wide linear range of 5.0 × 10 -5 -7.0 × 10 -3 M, limit of detection (LOD) of 1.19 × 10 -5 M along with excellent practical feasibility, storage stability, repeatability and selectivity towards AA electrooxidation showed the excellent synergy between nitrogen-rich GO surface and SnO PPs. The sensitivity (885.54 µAmM -1 cm -2 ) of the catalyst was the most attractive feature, as it was obtained in the presence of 5 and 2-fold higher concentration of UA and DA interfering species respectively. Copyright © 2018 Elsevier B.V. All rights reserved.
Pourahmadi, Mohammad Reza; Ebrahimi Takamjani, Ismail; Jaberzadeh, Shapour; Sarrafzadeh, Javad; Sanjari, Mohammad Ali; Bagheri, Rasool; Jannati, Elham
2018-06-01
Sit-to-stand (STD) and stand-to-sit (SIT) analysis can provide information on functional independence in daily activities in patients with low back pain (LBP). However, in order for measurements to be clinically useful, data on psychometric properties should be available. The main purpose was to investigate intra-rater reliability of STD and SIT tasks in participants with and without chronic non-specific LBP (CNLBP). The second purpose was to detect any differences in lumbar spine and hips sagittal plane kinematics and coordination between asymptomatic individuals and CNLBP patients during STD and SIT. Cross-sectional study. Twenty-three CNLBP patients and 23 demographically-matched controls were recruited. Ten markers were placed on specific anatomical landmarks. Participants were asked to perform STD and SIT at a preferred speed. Peak flexion angles, mean angular velocities, lumbar to hip movement ratios, and relative phase angles were measured. The procedure was repeated after 2 h and 6-8 days. Differences between two groups were analyzed using independent t-test. Intraclass correlation coefficient (ICC 3,k), standard error of measurement (SEM), and limits of agreement (LOAs) were also estimated. The ICC values showed moderate to excellent intra-rater reliability, with relatively low SEM values (≤10.17°). The 95% LOAs demonstrated that there were no differences between the measured parameters. Furthermore, CNLBP patients had limited sagittal plane angles, smaller angular velocities, and lumbar-hip dis-coordination compared to asymptomatic participants. The results indicated moderate to excellent test-retest reliability of STD and SIT analysis. Moreover, CNLBP patients had altered kinematics during STD and its reverse. Copyright © 2017 Elsevier Ltd. All rights reserved.
Zhou, Xiaotong; Meng, Xiangjun; Cheng, Longmei; Su, Chong; Sun, Yantong; Sun, Lingxia; Tang, Zhaohui; Fawcett, John Paul; Yang, Yan; Gu, Jingkai
2017-05-16
Polyethylene glycols (PEGs) are synthetic polymers composed of repeating ethylene oxide subunits. They display excellent biocompatibility and are widely used as pharmaceutical excipients. To fully understand the biological fate of PEGs requires accurate and sensitive analytical methods for their quantitation. Application of conventional liquid chromatography-tandem mass spectrometry (LC-MS/MS) is difficult because PEGs have polydisperse molecular weights (MWs) and tend to produce multicharged ions in-source resulting in innumerable precursor ions. As a result, multiple reaction monitoring (MRM) fails to scan all ion pairs so that information on the fate of unselected ions is missed. This Article addresses this problem by application of liquid chromatography-triple-quadrupole/time-of-flight mass spectrometry (LC-Q-TOF MS) based on the MS ALL technique. This technique performs information-independent acquisition by allowing all PEG precursor ions to enter the collision cell (Q2). In-quadrupole collision-induced dissociation (CID) in Q2 then effectively generates several fragments from all PEGs due to the high collision energy (CE). A particular PEG product ion (m/z 133.08592) was found to be common to all linear PEGs and allowed their total quantitation in rat plasma with high sensitivity, excellent linearity and reproducibility. Assay validation showed the method was linear for all linear PEGs over the concentration range 0.05-5.0 μg/mL. The assay was successfully applied to the pharmacokinetic study in rat involving intravenous administration of linear PEG 600, PEG 4000, and PEG 20000. It is anticipated the method will have wide ranging applications and stimulate the development of assays for other pharmaceutical polymers in the future.
Stabilization of perfect and imperfect tandem repeats by single-strand DNA exonucleases
Feschenko, Vladimir V.; Rajman, Luis A.; Lovett, Susan T.
2003-01-01
Rearrangements between tandemly repeated DNA sequences are a common source of genetic instability. Such rearrangements underlie several human genetic diseases. In many organisms, the mismatch-repair (MMR) system functions to stabilize repeats when the repeat unit is short or when sequence imperfections are present between the repeats. We show here that the action of single-stranded DNA (ssDNA) exonucleases plays an additional, important role in stabilizing tandem repeats, independent of their role in MMR. For perfect repeats of ≈100 bp in Escherichia coli that are not susceptible to MMR, exonuclease (Exo)-I, ExoX, and RecJ exonuclease redundantly inhibit deletion. Our data suggest that >90% of potential deletion events are avoided by the combined action of these three exonucleases. Imperfect tandem repeats, less prone to rearrangements, are stabilized by both the MMR-pathway and ssDNA-specific exonucleases. For 100-bp repeats containing four mispairs, ExoI alone aborts most deletion events, even in the presence of a functional MMR system. By genetic analysis, we show that the inhibitory effect of ssDNA exonucleases on deletion formation is independent of the MutS and UvrD proteins. Exonuclease degradation of DNA displaced during the deletion process may abort slipped misalignment. Exonuclease action is therefore a significant force in genetic stabilization of many forms of repetitive DNA. PMID:12538867
Are There Multiple Populations of Fast Radio Bursts?
NASA Astrophysics Data System (ADS)
Palaniswamy, Divya; Li, Ye; Zhang, Bing
2018-02-01
The repeating FRB 121102 (the “repeater”) shows repetitive bursting activities and was localized in a host galaxy at z = 0.193. On the other hand, despite dozens of hours of telescope time spent on follow-up observations, no other fast radio bursts (FRBs) have been observed to repeat. Yet, it has been speculated that the repeater is the prototype of FRBs, and that other FRBs should show similar repeating patterns. Using the published data, we compare the repeater with other FRBs in the observed time interval (Δt)–flux ratio (S i /S i+1) plane. We find that whereas other FRBs occupy the upper (large S i /S i+1) and right (large Δt) regions of the plane due to the non-detections of other bursts, some of the repeater bursts fall into the lower left region of the plot (short interval and small flux ratio) excluded by the non-detection data of other FRBs. The trend also exists even if one only selects those bursts detectable by the Parkes radio telescope. If other FRBs were similar to the repeater, our simulations suggest that the probability that none of them have been detected to repeat with the current searches would be ∼(10‑4–10‑3). We suggest that the repeater is not representative of the entire FRB population, and that there is strong evidence of more than one population of FRBs.
Development of Human Posture Simulation Method for Assessing Posture Angles and Spinal Loads
Lu, Ming-Lun; Waters, Thomas; Werren, Dwight
2015-01-01
Video-based posture analysis employing a biomechanical model is gaining a growing popularity for ergonomic assessments. A human posture simulation method of estimating multiple body postural angles and spinal loads from a video record was developed to expedite ergonomic assessments. The method was evaluated by a repeated measures study design with three trunk flexion levels, two lift asymmetry levels, three viewing angles and three trial repetitions as experimental factors. The study comprised two phases evaluating the accuracy of simulating self and other people’s lifting posture via a proxy of a computer-generated humanoid. The mean values of the accuracy of simulating self and humanoid postures were 12° and 15°, respectively. The repeatability of the method for the same lifting condition was excellent (~2°). The least simulation error was associated with side viewing angle. The estimated back compressive force and moment, calculated by a three dimensional biomechanical model, exhibited a range of 5% underestimation. The posture simulation method enables researchers to simultaneously quantify body posture angles and spinal loading variables with accuracy and precision comparable to on-screen posture matching methods. PMID:26361435
A marker placement laser device for improving repeatability in 3D-foot motion analysis.
Kalkum, Eva; van Drongelen, Stefan; Mussler, Johannes; Wolf, Sebastian I; Kuni, Benita
2016-02-01
In 3D gait analysis, the repeated positioning of markers is associated with a high error rate, particularly when using a complex foot model with many markers. Therefore, a marker placement laser device was developed that ensures a reliable repositioning of markers. We report the development and reliability of this device for the foot at different tape conditions. In 38 subjects, markers were placed at the foot according to the Heidelberg foot measurement method. Subjects were tested barefoot and barefoot with three different tape conditions. For all conditions, a static standing trial was captured. We analyzed differences in distances between markers and the intra-class correlation coefficients (ICC). Small differences between the conditions (0.03-3.28 mm) and excellent ICCs (0.91-0.97 mm) were found for all parameters. The laser marker placement device appeared to be a reliable method to place markers on a tape at previously palpated positions and ensures an exact position. The device could find a wide application in different clinical research fields. Copyright © 2015 Elsevier B.V. All rights reserved.
Hotel shows health system keys to service excellence.
2003-08-01
Ritz-Carlton partnership part of broader program pursuing service excellence. Nearly 600 system leaders will participate in day-long seminars. GE, Harvard serve as strategic partners for ongoing educational efforts.
Characterization of genetic sequence variation of 58 STR loci in four major population groups.
Novroski, Nicole M M; King, Jonathan L; Churchill, Jennifer D; Seah, Lay Hong; Budowle, Bruce
2016-11-01
Massively parallel sequencing (MPS) can identify sequence variation within short tandem repeat (STR) alleles as well as their nominal allele lengths that traditionally have been obtained by capillary electrophoresis. Using the MiSeq FGx Forensic Genomics System (Illumina), STRait Razor, and in-house excel workbooks, genetic variation was characterized within STR repeat and flanking regions of 27 autosomal, 7 X-chromosome and 24 Y-chromosome STR markers in 777 unrelated individuals from four population groups. Seven hundred and forty six autosomal, 227 X-chromosome, and 324 Y-chromosome STR alleles were identified by sequence compared with 357 autosomal, 107 X-chromosome, and 189 Y-chromosome STR alleles that were identified by length. Within the observed sequence variation, 227 autosomal, 156 X-chromosome, and 112 Y-chromosome novel alleles were identified and described. One hundred and seventy six autosomal, 123 X-chromosome, and 93 Y-chromosome sequence variants resided within STR repeat regions, and 86 autosomal, 39 X-chromosome, and 20 Y-chromosome variants were located in STR flanking regions. Three markers, D18S51, DXS10135, and DYS385a-b had 1, 4, and 1 alleles, respectively, which contained both a novel repeat region variant and a flanking sequence variant in the same nucleotide sequence. There were 50 markers that demonstrated a relative increase in diversity with the variant sequence alleles compared with those of traditional nominal length alleles. These population data illustrate the genetic variation that exists in the commonly used STR markers in the selected population samples and provide allele frequencies for statistical calculations related to STR profiling with MPS data. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Telles, Rosa Weiss; Costa-Silva, Luciana; Machado, Luciana A C; Reis, Rodrigo Citton Padilha Dos; Barreto, Sandhi Maria
To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). A test-retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5mm and ≤1.7mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference=1.08; coefficient of variation (%CV)=54.68%; intraclass correlation coefficient (ICC) (95%CI)=0.59 (0.34-0.77)]; JSW [SD of mean difference=0.34-0.61; %CV=4.48%-9.80%; ICC (95%CI)=0.74 (0.55-0.85)-0.94 (0.87-0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK. Copyright © 2016. Published by Elsevier Editora Ltda.
Schmuziger, Nicolas; Probst, Rudolf; Smurzynski, Jacek
2004-04-01
The purposes of the study were: (1) To evaluate the intrasession test-retest reliability of pure-tone thresholds measured in the 0.5-16 kHz frequency range for a group of otologically healthy subjects using Sennheiser HDA 200 circumaural and Etymotic Research ER-2 insert earphones and (2) to compare the data with existing criteria of significant threshold shifts related to ototoxicity and noise-induced hearing loss. Auditory thresholds in the frequency range from 0.5 to 6 kHz and in the extended high-frequency range from 8 to 16 kHz were measured in one ear of 138 otologically healthy subjects (77 women, 61 men; mean age, 24.4 yr; range, 12-51 yr) using HDA 200 and ER-2 earphones. For each subject, measurements of thresholds were obtained twice for both transducers during the same test session. For analysis, the extended high-frequency range from 8 to 16 kHz was subdivided into 8 to 12.5 and 14 to 16 kHz ranges. Data for each frequency and frequency range were analyzed separately. There were no significant differences in repeatability for the two transducer types for all frequency ranges. The intrasession variability increased slightly, but significantly, as frequency increased with the greatest amount of variability in the 14 to 16 kHz range. Analyzing each individual frequency, variability was increased particularly at 16 kHz. At each individual frequency and for both transducer types, intrasession test-retest repeatability from 0.5 to 6 kHz and 8 to 16 kHz was within 10 dB for >99% and >94% of measurements, respectively. The results indicated a false-positive rate of <3% in reference to the criteria for cochleotoxicity for both transducer types. In reference to the Occupational Safety and Health Administration Standard Threshold Shift criteria for noise-induced hazards, the results showed a minor false-positive rate of <1% for the HDA 200. Repeatability was similar for both transducer types. Intrasession test-retest repeatability from 0.5 to 12.5 kHz at each individual frequency including the frequency range susceptible to noise-induced hearing loss was excellent for both transducers. Repeatability was slightly, but significantly poorer in the frequency range from 14 to 16 kHz compared with the frequency ranges from 0.5 to 6 or 8 to 12.5 kHz. Measurements in the extended high-frequency range from 8 to 14 kHz, but not up to 16 kHz, may be recommended for monitoring purposes.
Recent social conditions affect boldness repeatability in individual sticklebacks.
Jolles, Jolle Wolter; Aaron Taylor, Benjamin; Manica, Andrea
2016-02-01
Animal personalities are ubiquitous across the animal kingdom and have been shown both to influence individual behaviour in the social context and to be affected by it. However, little attention has been paid to possible carryover effects of social conditions on personality expression, especially when individuals are alone. Here we investigated how the recent social context affected the boldness and repeatability of three-spined sticklebacks, Gasterosteus aculeatus , during individual assays. We housed fish either solitarily, solitarily part of the time or socially in groups of four, and subjected them twice to a risk-taking task. The social conditions had a large effect on boldness repeatability, with fish housed solitarily before the trials showing much higher behavioural repeatability than fish housed socially, for which repeatability was not significant. Social conditions also had a temporal effect on the boldness of the fish, with only fish housed solitarily taking more risks during the first than the second trial. These results show that recent social conditions can thus affect the short-term repeatability of behaviour and obfuscate the expression of personality even in later contexts when individuals are alone. This finding highlights the need to consider social housing conditions when designing personality studies and emphasizes the important link between animal personality and the social context by showing the potential role of social carryover effects.
Recent social conditions affect boldness repeatability in individual sticklebacks
Jolles, Jolle Wolter; Aaron Taylor, Benjamin; Manica, Andrea
2016-01-01
Animal personalities are ubiquitous across the animal kingdom and have been shown both to influence individual behaviour in the social context and to be affected by it. However, little attention has been paid to possible carryover effects of social conditions on personality expression, especially when individuals are alone. Here we investigated how the recent social context affected the boldness and repeatability of three-spined sticklebacks, Gasterosteus aculeatus, during individual assays. We housed fish either solitarily, solitarily part of the time or socially in groups of four, and subjected them twice to a risk-taking task. The social conditions had a large effect on boldness repeatability, with fish housed solitarily before the trials showing much higher behavioural repeatability than fish housed socially, for which repeatability was not significant. Social conditions also had a temporal effect on the boldness of the fish, with only fish housed solitarily taking more risks during the first than the second trial. These results show that recent social conditions can thus affect the short-term repeatability of behaviour and obfuscate the expression of personality even in later contexts when individuals are alone. This finding highlights the need to consider social housing conditions when designing personality studies and emphasizes the important link between animal personality and the social context by showing the potential role of social carryover effects. PMID:26949265
Datta, Indrani; Bhadri, Naini; Shahani, Pradnya; Majumdar, Debanjana; Sowmithra, Sowmithra; Razdan, Rema; Bhonde, Ramesh
2017-10-01
Diabetic neuropathy (DN) is among the most debilitating complications of diabetes. Here, we investigated the effects of human dental pulp stem cell (DPSC) transplantation in Streptozotocin (STZ)-induced neuropathic rats. Six weeks after STZ injection, DPSCs were transplanted through two routes, intravenous (IV) or intramuscular (IM), in single or two repeat doses. Two weeks after transplantation, a significant improvement in hyperalgesia, grip-strength, motor coordination and nerve conduction velocity was observed in comparison with controls. A rapid improvement in neuropathic symptoms was observed for a single dose of DPSC IV; however, repeat dose of DPSC IV did not bring about added improvement. A single dose of DPSC IM showed steady improvement, and further recovery continued upon repeat IM administration. DPSC single dose IV showed greater improvement than DPSC single dose IM, but IM transplantation brought about better improvement in body weight. A marked reduction in tumor necrosis factor (TNF) α and C-reactive protein (CRP) levels was observed in the blood plasma for all treated groups, as compared with controls. With respect to inflammatory cytokines, repeat dose of DPSC IM showed further improvement, suggesting that a repeat dose is required to maintain the improved inflammatory state. Gene expression of inflammatory markers in liver confirmed amelioration in inflammation. Arachidonic acid level was unaffected by IV DPSC transplantation but showed noticeable increase through IM administration of a repeat dose. These results suggest that DPSC transplantation through both routes and dosage was beneficial for the retrieval of neuropathic parameters of DN; transplantation via the IM route with repeat dose was the most effective. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.
Aporntewan, Chatchawit; Pin-on, Piyapat; Chaiyaratana, Nachol; Pongpanich, Monnat; Boonyaratanakornkit, Viroj; Mutirangura, Apiwat
2013-10-01
A-repeats are the simplest form of tandem repeats and are found ubiquitously throughout genomes. These mononucleotide repeats have been widely believed to be non-functional 'junk' DNA. However, studies in yeasts suggest that A-repeats play crucial biological functions, and their role in humans remains largely unknown. Here, we showed a non-random pattern of distribution of sense A- and T-repeats within 20 kb around transcription start sites (TSSs) in the human genome. Different distributions of these repeats are observed upstream and downstream of TSSs. Sense A-repeats are enriched upstream, whereas sense T-repeats are enriched downstream of TSSs. This enrichment directly correlates with repeat size. Genes with different functions contain different lengths of repeats. In humans, tissue-specific genes are enriched for short repeats of <10 bp, whereas housekeeping genes are enriched for long repeats of ≥10 bp. We demonstrated that DICER1 and Argonaute proteins are required for the cis-regulatory role of A-repeats. Moreover, in the presence of a synthetic polymer that mimics an A-repeat, protein binding to A-repeats was blocked, resulting in a dramatic change in the expression of genes containing upstream A-repeats. Our findings suggest a length-dependent cis-regulatory function of A-repeats and that Argonaute proteins serve as trans-acting factors, binding to A-repeats.
Dubey, Deepak
2011-01-01
Introduction: Direct visual internal urethrotomy (DVIU) followed by intermittent self-dilatation (ISD) is the most commonly performed intervention for urethral stricture disease. The objective of this paper is to outline the current scientific evidence supporting this approach for its use in the management of anterior urethral strictures. Materials and Methods: A Pubmed database search was performed with the words “internal urethrotomy” and “internal urethrotomy” self-catheterization. All papers dealing with this subject were scrutinized. Cross-references from the retrieved articles were also viewed. Only English language articles were included in the analyses. Studies were analyzed to identify predictors for success for DVIU. Results: Initial studies showed excellent outcomes with DVIU with success rates ranging from 50% to 85%. However, these studies reported only short-term results. Recent studies with longer followup have shown a poor success rate ranging from 6% to 28%. Stricture length and degree of fibrosis (luminal narrowing) were found to be predictors of response. Repeated urethrotomies were associated with poor results. Studies involving intermittent self-catheterization following DVIU have shown no role in short-term ISD with one study reporting beneficial effects if continued for more than a year. A significant number of studies have shown long-term complications with SC and high dropout rates. Conclusions: DVIU is associated with poor long-term cure rates. It remains as a treatment of first choice for bulbar urethral strictures <1 cm with minimal spongiofibrosis. There is no role for repeated urethrotomy as outcomes are uniformly poor. ISD, when used for more than a year on a weekly or biweekly basis may delay the onset of stricture recurrence. PMID:22022065
Cleary, John D; Tomé, Stéphanie; López Castel, Arturo; Panigrahi, Gagan B; Foiry, Laurent; Hagerman, Katharine A; Sroka, Hana; Chitayat, David; Gourdon, Geneviève; Pearson, Christopher E
2010-09-01
Myotonic dystrophy, caused by DM1 CTG/CAG repeat expansions, shows varying instability levels between tissues and across ages within patients. We determined DNA replication profiles at the DM1 locus in patient fibroblasts and tissues from DM1 transgenic mice of various ages showing different instability. In patient cells, the repeat is flanked by two replication origins demarcated by CTCF sites, with replication diminished at the expansion. In mice, the expansion replicated from only the downstream origin (CAG as lagging template). In testes from mice of three different ages, replication toward the repeat paused at the earliest age and was relieved at later ages-coinciding with increased instability. Brain, pancreas and thymus replication varied with CpG methylation at DM1 CTCF sites. CTCF sites between progressing forks and repeats reduced replication depending on chromatin. Thus, varying replication progression may affect tissue- and age-specific repeat instability.
The Repeated Name Penalty, the Overt Pronoun Penalty, and Topic in Japanese.
Shoji, Shinichi; Dubinsky, Stanley; Almor, Amit
2017-02-01
When reading sentences with an anaphoric reference to a subject antecedent, repeated-name anaphors result in slower reading times relative to pronouns (the Repeated Name Penalty: RNP), and overt pronouns are read slower than null pronouns (the Overt Pronoun Penalty: OPP). Because in most languages previously tested, the grammatical subject is typically also the discourse topic it remains unclear whether these effects reflect anaphors' subject-hood or their topic-hood. To address this question we conducted a self-paced reading experiment in Japanese, a language which morphologically marks both subjects and topics overtly. Our results show that both repeated-name topic-subject anaphors and repeated-name non-topic-subject anaphors exhibit the RNP and that both overt-pronoun topic-subject and overt-pronoun non-topic-subject anaphors show the OPP. However, a detailed examination of performance revealed an interaction between the anaphor topic marking, reference form, and the antecedent's grammatical status, indicating that the effect of the antecedent's grammatical status is strongest for null pronoun and repeated name subject anaphors and that the overt form most similar to null pronouns is the repeated name topic anaphor. We discuss the implications of these findings for theories of anaphor processing.
StaRProtein, A Web Server for Prediction of the Stability of Repeat Proteins
Xu, Yongtao; Zhou, Xu; Huang, Meilan
2015-01-01
Repeat proteins have become increasingly important due to their capability to bind to almost any proteins and the potential as alternative therapy to monoclonal antibodies. In the past decade repeat proteins have been designed to mediate specific protein-protein interactions. The tetratricopeptide and ankyrin repeat proteins are two classes of helical repeat proteins that form different binding pockets to accommodate various partners. It is important to understand the factors that define folding and stability of repeat proteins in order to prioritize the most stable designed repeat proteins to further explore their potential binding affinities. Here we developed distance-dependant statistical potentials using two classes of alpha-helical repeat proteins, tetratricopeptide and ankyrin repeat proteins respectively, and evaluated their efficiency in predicting the stability of repeat proteins. We demonstrated that the repeat-specific statistical potentials based on these two classes of repeat proteins showed paramount accuracy compared with non-specific statistical potentials in: 1) discriminate correct vs. incorrect models 2) rank the stability of designed repeat proteins. In particular, the statistical scores correlate closely with the equilibrium unfolding free energies of repeat proteins and therefore would serve as a novel tool in quickly prioritizing the designed repeat proteins with high stability. StaRProtein web server was developed for predicting the stability of repeat proteins. PMID:25807112
Xie, Lingling; Xu, Yuandong; Cao, Xiaoyu
2013-07-01
In this work, a highly sensitive hydrogen peroxide (H2O2) biosensor based on immobilization of hemoglobin (Hb) at Au nanoparticles (AuNPs)/flower-like zinc oxide/graphene (AuNPs/ZnO/Gr) composite modified glassy carbon electrode (GCE) was constructed, where ZnO and Au nanoparticles were modified through layer-by-layer onto Gr/GCE. Flower-like ZnO nanoparticles could be easily prepared by adding ethanol to the precursor solution having higher concentration of hydroxide ions. The Hb/AuNPs/ZnO/Gr composite film showed a pair of well-defined, quasi-reversible redox peaks with a formal potential (E(0)) of -0.367 V, characteristic features of heme redox couple of Hb. The electron transfer rate constant (k(s)) of immobilized Hb was 1.3 s(-1). The developed biosensor showed a very fast response (<2 s) toward H2O2 with good sensitivity, wide linear range, and low detection limit of 0.8 μM. The fabricated biosensor showed interesting features, including high selectivity, acceptable stability, good reproducibility, and repeatability along with excellent conductivity, facile electron mobility of Gr, and good biocompatibility of ZnO and AuNPs. The fabrication method of this biosensor was simple and effective for determination of H2O2 in real samples with quick response, good sensitivity, high selectivity, and acceptable recovery. Copyright © 2013 Elsevier B.V. All rights reserved.
Tanaka, Hirokazu; Chikamori, Taishiro; Hida, Satoshi; Uchida, Kenji; Igarashi, Yuko; Yokoyama, Tsuyoshi; Takahashi, Masaki; Shiba, Chie; Yoshimura, Mana; Tokuuye, Koichi; Yamashina, Akira
2013-01-01
Cadmium-zinc-telluride (CZT) solid-state detectors have been recently introduced into the field of myocardial perfusion imaging. The aim of this study was to prospectively compare the diagnostic performance of the CZT high-speed gamma camera (Discovery NM 530c) with that of the standard 3-head gamma camera in the same group of patients. The study group consisted of 150 consecutive patients who underwent a 1-day stress-rest (99m)Tc-sestamibi or tetrofosmin imaging protocol. Image acquisition was performed first on a standard gamma camera with a 15-min scan time each for stress and for rest. All scans were immediately repeated on a CZT camera with a 5-min scan time for stress and a 3-min scan time for rest, using list mode. The correlations between the CZT camera and the standard camera for perfusion and function analyses were strong within narrow Bland-Altman limits of agreement. Using list mode analysis, image quality for stress was rated as good or excellent in 97% of the 3-min scans, and in 100% of the ≥4-min scans. For CZT scans at rest, similarly, image quality was rated as good or excellent in 94% of the 1-min scans, and in 100% of the ≥2-min scans. The novel CZT camera provides excellent image quality, which is equivalent to standard myocardial single-photon emission computed tomography, despite a short scan time of less than half of the standard time.
The long-term reliability of static and dynamic quantitative sensory testing in healthy individuals.
Marcuzzi, Anna; Wrigley, Paul J; Dean, Catherine M; Adams, Roger; Hush, Julia M
2017-07-01
Quantitative sensory tests (QSTs) have been increasingly used to investigate alterations in somatosensory function in a wide range of painful conditions. The interpretation of these findings is based on the assumption that the measures are stable and reproducible. To date, reliability of QST has been investigated for short test-retest intervals. The aim of this study was to investigate the long-term reliability of a multimodal QST assessment in healthy people, with testing conducted on 3 occasions over 4 months. Forty-two healthy people were enrolled in the study. Static and dynamic tests were performed, including cold and heat pain threshold (CPT, HPT), mechanical wind-up [wind-up ratio (WUR)], pressure pain threshold (PPT), 2-point discrimination (TPD), and conditioned pain modulation (CPM). Systematic bias, relative reliability and agreement were analysed using repeated measure analysis of variance, intraclass correlation coefficients (ICCs3,1) and SE of the measurement (SEM), respectively. Static QST (CPT, HPT, PPT, and TPD) showed good-to-excellent reliability (ICCs: 0.68-0.90). Dynamic QST (WUR and CPM) showed poor-to-good reliability (ICCs: 0.35-0.61). A significant linear decrease over time was observed for mechanical QST at the back (PPT and TPD) and for CPM (P < 0.01). Static QST were stable over a period of 4 months; however, a small systematic decrease over time has been observed for mechanical QST. Dynamic QST showed considerable variability over time; in particular, CPM using PPT as the test stimulus did not show adequate reliability, suggesting that this test paradigm may be less useful for monitoring individuals over time.
Spinocerebellar ataxia 17: full phenotype in a 41 CAG/CAA repeats carrier.
Origone, Paola; Gotta, Fabio; Lamp, Merit; Trevisan, Lucia; Geroldi, Alessandro; Massucco, Davide; Grazzini, Matteo; Massa, Federico; Ticconi, Flavia; Bauckneht, Matteo; Marchese, Roberta; Abbruzzese, Giovanni; Bellone, Emilia; Mandich, Paola
2018-01-01
Spinocerebellar ataxia 17 (SCA17) is one of the most heterogeneous forms of autosomal dominant cerebellar ataxias with a large clinical spectrum which can mimic other movement disorders such as Huntington disease (HD), dystonia and parkinsonism. SCA17 is caused by an expansion of CAG/CAA repeat in the Tata binding protein ( TBP ) gene. Normal alleles contain 25 to 40 CAG/CAA repeats, alleles with 50 or greater CAG/CAA repeats are pathological with full penetrance. Alleles with 43 to 49 CAG/CAA repeats were also reported and their penetrance is estimated between 50 and 80%. Recently few symptomatic individuals having 41 and 42 repeats were reported but it is still unclear whether CAG/CAA repeats of 41 or 42 are low penetrance disease-causing alleles. Thus, phenotypic variability like the disease course in subject with SCA17 locus restricted expansions remains to be fully understood. The patients was a 63-year-old woman who, at 54 years, showed personality changes and increased frequency of falls. At 55 years of age neuropsychological tests showed executive attention and visuospatial deficit. At the age of 59 the patient developed dysarthria and a progressive cognitive deficit. The neurological examination showed moderate gait ataxia, dysdiadochokinesia and dysmetria, dysphagia, dysarthria and abnormal saccadic pursuit, severe axial asynergy during postural changes, choreiform dyskinesias. Molecular analysis of the TBP gene demonstrated an allele with 41 repeat suggesting that 41 CAG/CCG TBP repeats could be an allele associated with the full clinical spectrum of SCA17. The described case with the other similar cases described in the literature suggests that 41 CAG/CAA trinucleotides should be considered as critical threshold in SCA17. We suggest that SCA17 diagnosis should be suspected in patients presenting with movement disorders associated with other neurodegenerative signs and symptoms.
Muscle deoxygenation and neural drive to the muscle during repeated sprint cycling.
Racinais, Sébastien; Bishop, David; Denis, Romain; Lattier, Grégory; Mendez-Villaneuva, Alberto; Perrey, Stéphane
2007-02-01
To investigate muscle deoxygenation and neural drive-related changes during repeated cycling sprints in a fatiguing context. Nine healthy male subjects performed a repeated-sprint test (consisting of 10 x 6-s maximal sprints interspaced by 30 s of recovery). Oxygen uptake was measured breath-by-breath; muscle deoxygenation of the vastus lateralis was assessed continuously using the near-infrared spectroscopy technique. Surface electromyograms (RMS) of both vastus lateralis and biceps femoris were also recorded. Furthermore, before and after the repeated-sprint test, the percentage of muscle activation by voluntary drive (twitch-interpolated method) was measured during a maximal voluntary contraction. Consistent with previous research, our data showed a significant power decrement during repeated-sprint exercise. There was also a progressive muscle deoxygenation, but our data showed that the ability of the subjects to use available O2 throughout the entire repeated-sprint test was well preserved. Our data displayed a significant decrement in the RMS activity during the acceleration phase of each sprint across the repeated-sprint exercise. Moreover, decrement in motor drive was confirmed after exercise by a significant decrease in both percentage of voluntary activation and RMS/M-wave ratio during a maximal voluntary contraction. In this experimental design, our findings suggest that the ability to repeat short-duration (6 s) sprints was associated with the occurrence of both peripheral and central fatigue.
Goren, Moran G; Yosef, Ido; Auster, Oren; Qimron, Udi
2012-10-12
We analyzed sequences of newly inserted repeats in an Escherichia coli CRISPR (clustered regularly interspaced short palindromic repeats) array in vivo and showed that a base previously thought to belong to the repeat is actually derived from a protospacer. Based on further experimental results, we propose to use the term "duplicon" for a repeated sequence in a CRISPR array that serves as a template for a new duplicon. Our findings suggest the possibility of redrawing the borders between repeats, spacers, and protospacer adjacent motifs. Copyright © 2012 Elsevier Ltd. All rights reserved.
Mousavi, S A; Hermundstad, B; Kjustad Frøyland, E M; Llohn, A H; Knutsen, T R
2014-08-01
Anecdotal evidence suggests that missed donation appointments among repeat whole-blood donors are associated with decreased likelihood of future blood donation. This study sought to examine the relationship between missed donation appointments and intention to donate again among repeat whole-blood donors and to examine whether demographic variables are related to appointment-keeping behaviour. During the period February-June 2013, telephone interviews were conducted with repeat donors who either did not show up for or cancelled their donation appointments on the day of the appointment. We asked them whether or not they wanted to schedule appointments for subsequent donations. Rates of missed donation appointments varied by age, but not gender. Although a statistically significant difference between male and female donors was not found with regard to willingness to donate again, female donors were more likely than male donors to call and cancel their appointment. Finally, compared with repeat donors who called and cancelled their appointment, no-show donors were 2.5 times less likely to schedule appointments for subsequent donations (P < 0.001). The results demonstrate that poor appointment-keeping behaviour, and in particular no-show behaviour, is significantly associated with decreased likelihood of future blood donation among repeat whole-blood donors. © 2014 The Authors. Transfusion Medicine © 2014 British Blood Transfusion Society.
Previous work showed that trichloroethylene (TCE) impairs sustained attention as evidenced by a reduction in accuracy and elevation of response latencies in rats trained to perform a visual signal detection task (SDT). This work also showed that these effects abate during repeat...
Development of electrochemical super capacitors for EMA applications
NASA Technical Reports Server (NTRS)
Kosek, J. A.; Dunning, T.; Laconti, A. B.
1995-01-01
In a NASA SBIR Phase I program (Contract No. NAS8-40119), Giner, Inc. evaluated the feasibility of fabricating an all-solid-ionomer multicell electrochemical capacitor having a unit cell capacitance greater than 2 F/sq cm and a repeating element thickness of 6 mils. This capacitor can possibly be used by NASA as a high-rate energy source for electromechanical actuator (EMA) activation for advanced space missions. The high unit cell capacitance and low repeating element thickness will allow for the fabrication of a low-volume, low-weight device, favorable characteristics for space applications. These same characteristics also make the capacitor attractive for terrestrial applications, such as load-leveling batteries or fuel cells in electric vehicle applications. Although the projected energy densities for electrochemical capacitors are about two orders of magnitude lower than that of batteries, the high-power-density characteristics of these devices render them as potentially viable candidates for meeting pulse or peak electrical power requirements for some anticipated aerospace mission scenarios, especially those with discharge times on the millisecond to second time scale. On a volumetric or gravimetric basis, the advantages of utilizing electrochemical capacitors rather than batteries for meeting the peak power demands associated with a specific mission scenario will largely depend upon the total and pulse durations of the power peaks. The effect of preparation conditions on RuO(x), the active component in an all-solid-ionomer electrochemical capacitor, was evaluated during this program. Methods were identified to prepare RuO(x) having a surface areagreater than 180 sq m/g, and a capacitance of greater than 2 F/sq cm. Further efforts to reproducibly obtain these high-surface-area materials in scaled-up batches will be evaluated in Phase 2. During this Phase 1 program we identified a superior Nafion 105 membrane, having a film thickness of 5 mils, that showed excellent performance in our all-solid-ionomer capacitors and resulted in electrochemical capacitors with a repeating element thickness of 8 mils. We are currently working with membrane manufacturers to obtain a high performance membrane in less than 3 mil thickness to obtain a repeating element thickness of 6 mils or less. A 10-cell all-solid ionomer capacitor stack, with each cell having a 222 sq cm active area, was fabricated and evaluated as part of the Phase 1 program. Further Scale-up of a high-energy-density stack is plannedin Phase 2.
Nandini, Seetharamaiah; Nalini, Seetharamaiah; Reddy, M B Madhusudana; Suresh, Gurukar Shivappa; Melo, Jose Savio; Niranjana, Pathappa; Sanetuntikul, Jakkid; Shanmugam, Sangaraju
2016-08-01
This manuscript reports a new approach for the synthesis of one dimensional gold nanostructure (AuNs) and its application in the development of cholesterol biosensor. Au nanostructures have been synthesized by exploiting β-diphenylalanine (β-FF) as an sacrificial template, whereas the Au nanoparticles (AuNPs) were synthesized by ultrasound irradiation. X-ray diffractometer (XRD), scanning electron microscope (SEM) and energy dispersive analysis of X-rays (EDAX) have been employed to characterize the morphology and composition of the prepared samples. With the aim to develop a highly sensitive cholesterol biosensor, cholesterol oxidase (ChOx) was immobilized on AuNs which were appended on the graphite (Gr) electrode via chemisorption onto thiol-functionalized graphene oxide (GO-SH). This Gr/GO-SH/AuNs/ChOx biosensor has been characterized using cyclic voltammetry (CV), electrochemical impedance spectroscopy and chronoamperometry. CV results indicated a direct electron transfer between the enzyme and the electrode surface. A new potentiostat intermitant titration technique (PITT) has been studied to determine the diffusion coefficient and maxima potential value. The proposed biosensor showed rapid response, high sensitivity, wide linear range and low detection limit. Furthermore, our AuNs modified electrode showed excellent selectivity, repeatability, reproducibility and long term stability. The proposed electrode has also been used successfully to determine cholesterol in serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.
An Enzyme-Induced Novel Biosensor for the Sensitive Electrochemical Determination of Isoniazid
Chokkareddy, Rajasekhar; Bhajanthri, Natesh Kumar; Redhi, Gan G.
2017-01-01
In this present work, a glassy carbon electrode (GCE) was modified primarily with multiwalled carbon nanotubes (MWCNTs) and a composite of MWCNTs and titanium oxide nanoparticles (TiO2NPs). The enzyme horseradish peroxidase (HRP) was immobilized to enhance the sensing ability of GCE. The proposed biosensor was used for the sensitive determination of isoniazid (INZ) in various pharmaceutical samples. The electrochemical behaviour of the developed MWCNT-TiO2NPs-HRP-GCE biosensor was studied by using cyclic voltammetry (CV) and differential pulse voltammetric (DPV) techniques. Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), thermogravimetry (TGA) and transmission electron microscopy (TEM) techniques were used to characterize the developed sensor. Phosphate buffer solution (PBS) with pH 7 was used as supporting electrolyte in the present investigation. The cyclic voltammetric results revealed that the increment of anodic peak currents for the enzyme-induced sensor was almost 8-fold greater than that of a bare GCE. The DPV technique exhibited good limit of detection and limit of quantification values, viz., 0.0335 μM and 0.1118 μM, respectively. Moreover, the developed sensor showed long-lasting stability and repeatability without any interferents. This strongly indicates that the fabricated sensor shows outstanding electrochemical performance towards INZ, with excellent selectivity and sensitivity. The developed sensor was successfully applied to pharmaceutical samples and gave good percentages of recoveries. PMID:28587260
Ara, Mirian; Pajarin, Ana B.
2015-01-01
Objective. To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. Methods. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. Results. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. Conclusions. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression. PMID:26185762
RNA editing of non-coding RNA and its role in gene regulation.
Daniel, Chammiran; Lagergren, Jens; Öhman, Marie
2015-10-01
It has for a long time been known that repetitive elements, particularly Alu sequences in human, are edited by the adenosine deaminases acting on RNA, ADAR, family. The functional interpretation of these events has been even more difficult than that of editing events in coding sequences, but today there is an emerging understanding of their downstream effects. A surprisingly large fraction of the human transcriptome contains inverted Alu repeats, often forming long double stranded structures in RNA transcripts, typically occurring in introns and UTRs of protein coding genes. Alu repeats are also common in other primates, and similar inverted repeats can frequently be found in non-primates, although the latter are less prone to duplex formation. In human, as many as 700,000 Alu elements have been identified as substrates for RNA editing, of which many are edited at several sites. In fact, recent advancements in transcriptome sequencing techniques and bioinformatics have revealed that the human editome comprises at least a hundred million adenosine to inosine (A-to-I) editing sites in Alu sequences. Although substantial additional efforts are required in order to map the editome, already present knowledge provides an excellent starting point for studying cis-regulation of editing. In this review, we will focus on editing of long stem loop structures in the human transcriptome and how it can effect gene expression. Copyright © 2015 Elsevier B.V. and Société Française de Biochimie et Biologie Moléculaire (SFBBM). All rights reserved.
Keys, C; Kemper, S; Keim, P
2005-01-01
Evaluation of the Escherichia coli genome for variable number tandem repeat (VNTR) loci in order to provide a subtyping tool with greater discrimination and more efficient capacity. Twenty-nine putative VNTR loci were identified from the E. coli genomic sequence. Their variability was validated by characterizing the number of repeats at each locus in a set of 56 E. coli O157:H7/HN and O55:H7 isolates. An optimized multiplex assay system was developed to facility high capacity analysis. Locus diversity values ranged from 0.23 to 0.95 while the number of alleles ranged from two to 29. This multiple-locus VNTR analysis (MLVA) data was used to describe genetic relationships among these isolates and was compared with PFGE (pulse field gel electrophoresis) data from a subset of the same strains. Genetic similarity values were highly correlated between the two approaches, through MLVA was capable of discrimination amongst closely related isolates when PFGE similar values were equal to 1.0. Highly variable VNTR loci exist in the E. coli O157:H7 genome and are excellent estimators of genetic relationships, in particular for closely related isolates. Escherichia coli O157:H7 MLVA offers a complimentary analysis to the more traditional PFGE approach. Application of MLVA to an outbreak cluster could generate superior molecular epidemiology and result in a more effective public health response.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schaefer, F.V.; Calikoglu, A.S.; Whetsell, L.H.
1994-09-01
Instability and enlargement of a CAG repeat region at the beginning of the huntingtin gene (IT-15) has been linked with Huntington`s disease. The CAG repeat size shows a highly significant correlation with age-of-onset of clinicial features in individuals with 40 or more repeats who have Huntington disease. The clinical status of nonsymptomatic individuals with 30 to 39 CAG repeats is considered ambiguous. In order to define more carefully the nature of the HD expansion instability, we examined patients in our HD population using a discriminating fluorescence-based PCR approach. The degree of somatic mutation increases with both earlier age of onsetmore » and the size of the inherited allele. A single prominent band one repeat larger than the index peak was typical in individuals with 40-41 CAG repeats. Three to four larger bands are typically discerned in individuals with 50 or more repeats. In an extreme example, an individual with approximately 95 repeats had at least 8 prominent bands. Plotting the degree of somatic mutation relative to the size of the HD allele shows somatic mutation activity increases with size. By this approach 40-60% of the alleles in a 40-41 CAG repeat HD loci is represented in the primary allele. In contrast, the primary allele represents a relatively minor proportion of the total alleles for expansions greater than 50 CAG repeats (10-20%). The limited range of somatic mutation suggest that the instability is restricted to very early stages of embryogenesis before tissue development diverges or that persistent somatic instability occurs at a slow rate. Therefore, the properties of somatic instability in Huntington`s disease have aspects that are both in common but also different from that found in other trinucleotide repeat expanding diseases such as myotonic muscular dystrophy and fragile X syndrome.« less
ERIC Educational Resources Information Center
Nakata, Tatsuya
2017-01-01
Although research shows that repetition increases second language vocabulary learning, only several studies have examined the long-term effects of increasing retrieval frequency in one learning session. With this in mind, the present study examined the effects of within-session repeated retrieval on vocabulary learning. The study is original in…
Previous work showed that trichloroethylene (TCE) impairs accuracy and latency in a signal detection task (SDT) in rats, and that these effects abate during repeated exposures if rats inhale TCE during SDT testing. The present experiment compared the effects of acute and repeated...
The myotonic dystrophy kinase 3{prime}-untranslated region and its effect on gene expression
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ang, C.W.Y.; Sabourin, L.A.; Narang, M.A.
1994-09-01
Myotonic dystrophy (DM) is an autosomal dominant neuromuscular disease involving the expansion of an unstable CTG repeat in the 3{prime}-untranslated (3{prime}-UTR) region of the DM kinase (DMK) gene. Increased levels of mRNA in congenital compared to normal tissue have been shown, suggesting elevated DMK levels may be responsible for the disease phenotype. To study the effect of the DMK 3{prime}UTR on gene expression, a reporter gene system was constructed using the constitutive CMV promoter with the chloramphenicol acetyl transferase (CAT) open reading frame and the DMK 3{prime}UTR containing from 5 repeats up to 90 repeats. Transient transfection into a rhabdomyosarcomamore » cell line shows a three-fold increase in CAT activity from constructs containing a wildtype 3{prime}UTR (5 and 20 repeats) compared to a control construct containing only a poly(A) signal. Reporter constructs with repeats in the protomutation (50 repeats) and mutation (90 repeats) range show a greater than 10-fold increase over control CAT activity. These results suggest the presence of elements in the DMK 3{prime}UTR capable of conferring increased gene expression. We are currently investigating cell-specific activity of the constructs and conducting deletion mapping to identify regulatory elements in the 3{prime}-UTR.« less
NASA Astrophysics Data System (ADS)
Song, Tingting; Liu, Qi; Liu, Jingyuan; Yang, Wanlu; Chen, Rongrong; Jing, Xiaoyan; Takahashi, Kazunobu; Wang, Jun
2015-11-01
Inspired by natural plants such as Nepenthes pitcher plants, super slippery surfaces have been developed to improve the attributes of repellent surfaces. In this report, super slippery porous anodic aluminium oxide (AAO) surfaces have fabricated by a simple and reproducible method. Firstly, the aluminium substrates were treated by an anodic process producing micro-nano structured sheet-layered pores, and then immersed in Methyl Silicone Oil, Fluororalkylsilane (FAS) and DuPont Krytox, respectively, generating super slippery surfaces. Such a good material with excellent anti-corrosion property through a simple and repeatable method may be potential candidates for metallic application in anti-corrosion and extreme environment.
Cheng, Bei; Xu, Peisheng
2017-01-01
Various gold nanoparticles have been explored in biomedical systems and proven to be promising in photothermal therapy and drug delivery. Among them, nanoshells were regarded as traditionally strong near infrared absorbers that have been widely used to generate photothermal effect for cancer therapy. However, the nanoshell is not photo-thermal stable and thus is not suitable for repeated irradiation. Here, we describe a novel discrete gold nanostructure by mimicking the continuous gold nanoshell-gold/mesoporous silica hybrid nanoparticle (GoMe). It possesses the best characteristics of both conventional gold nanoparticles and mesoporous silica nanoparticles, such as excellent photothermal converting ability as well as high drug loading capacity and triggerable drug release.
Cannulation in patients with large periampullary diverticulum using SpyBite miniforceps.
Balkrishanan, Mahadevan; Jain, Mayank; Snk, Chenduran; Cg, Sridhar; Ramakrishnan, Ravi; Venkataraman, Jayanthi
2018-03-01
Cannulation is difficult in patients with periampullary diverticulum (PAD). The described success rate varies from 61% to 95.4%. Four cases with PAD in which, despite repeated attempts, we were unable to locate the papilla and cannulate. To overcome this difficulty, we used SpyBite forceps (Boston Scientific) to pull out the papillary orifice and then perform the cannulation using a sphincterotome introduced through the same working channel. This method reduced the time required for cannulation. In all four of our cases, we had 100% success in cannulation. Use of SpyBite miniforceps in difficult cannulations in patients with PAD is useful and has an excellent success rate.
A polydimethylsiloxane (PDMS) sponge for the selective absorption of oil from water.
Choi, Sung-Jin; Kwon, Tae-Hong; Im, Hwon; Moon, Dong-Il; Baek, David J; Seol, Myeong-Lok; Duarte, Juan P; Choi, Yang-Kyu
2011-12-01
We present a sugar-templated polydimethylsiloxane (PDMS) sponge for the selective absorption of oil from water. The process for fabricating the PDMS sponge does not require any intricate synthesis processes or equipment and it is not environmentally hazardous, thus promoting potential in environmental applications. The proposed PDMS sponge can be elastically deformed into any shape, and it can be compressed repeatedly in air or liquids without collapsing. Therefore, absorbed oils and organic solvents can be readily removed and reused by simply squeezing the PDMS sponge, enabling excellent recyclability. Furthermore, through appropriately combining various sugar particles, the absorption capacity of the PDMS sponge is favorably optimized. © 2011 American Chemical Society
A new helium gas bearing turboexpander
NASA Astrophysics Data System (ADS)
Xiong, L. Y.; Chen, C. Z.; Liu, L. Q.; Hou, Y.; Wang, J.; Lin, M. F.
2002-05-01
A new helium gas bearing turboexpander of a helium refrigeration system used for space environment simulation experiments is described in this paper. The main design parameters and construction type of some key parts are presented. An improved calculation of thermodynamic efficiency and instability speed of this turboexpander has been obtained by a multiple objects optimization program. Experiments of examining mechanical and thermodynamic performance have been repeatedly conducted in the laboratory by using air at ambient and liquid nitrogen temperature, respectively. In order to predict the helium turboexpander performance, a similarity principles study has been developed. According to the laboratory and on-the-spot experiments, the mechanical and thermodynamic performances of this helium turboexpander are excellent.
NASA Astrophysics Data System (ADS)
Avila, Julian A.; Lucon, Enrico; Sowards, Jeffrey; Mei, Paulo Roberto; Ramirez, Antonio J.
2016-06-01
Friction-stir welding (FSW) is an alternative welding process for pipelines. This technology offers sound welds, good repeatability, and excellent mechanical properties. However, it is of paramount importance to determine the toughness of the welds at low temperatures in order to establish the limits of this technology. Ductile-to-brittle transition curves were generated in the present study by using a small-scale instrumented Charpy machine and miniaturized V-notch specimens (Kleinstprobe, KLST); notches were located in base metal, heat-affected, stirred, and hard zones within a FSW joint of API-5L X80 Pipeline Steel. Specimens were tested at temperatures between 77 K (-196 °C) and 298 K (25 °C). Based on the results obtained, the transition temperatures for the base material and heat-affected zone were below 173 K (-100 °C); conversely, for the stirred and hard zones, it was located around 213 K (-60 °C). Fracture surfaces were characterized and showed a ductile fracture mechanism at high impact energies and a mixture of ductile and brittle mechanisms at low impact energies.
Graphene-Carbon-Metal Composite Film for a Flexible Heat Sink.
Cho, Hyunjin; Rho, Hokyun; Kim, Jun Hee; Chae, Su-Hyeong; Pham, Thang Viet; Seo, Tae Hoon; Kim, Hak Yong; Ha, Jun-Seok; Kim, Hwan Chul; Lee, Sang Hyun; Kim, Myung Jong
2017-11-22
The heat generated from electronic devices such as light emitting diodes (LEDs), batteries, and highly integrated transistors is one of the major causes obstructing the improvement of their performance and reliability. Herein, we report a comprehensive method to dissipate the generated heat to a vast area by using the new type of graphene-carbon-metal composite film as a heat sink. The unique porous graphene-carbon-metal composite film that consists of an electrospun carbon nanofiber with arc-graphene (Arc-G) fillers and an electrochemically deposited copper (Cu) layer showed not only high electrical and thermal conductivity but also high mechanical stability. Accordingly, superior thermal management of LED devices to that of conventional Cu plates and excellent resistance stability during the repeated 10 000 bending cycles has been achieved. The heat dissipation of LEDs has been enhanced by the high heat conduction in the composite film, heat convection in the air flow, and thermal radiation at low temperature in the porous carbon structure. This result reveals that the graphene-carbon-metal composite film is one of the most promising materials for a heat sink of electronic devices in modern electronics.
NASA Astrophysics Data System (ADS)
Beaulieu, L. Y.; Logan, E. R.; Gering, K. L.; Dahn, J. R.
2017-09-01
An automated system was developed to measure the viscosity of fluids as a function of temperature using image analysis tracking software. An Ostwald viscometer was placed in a three-wall dewar in which ethylene glycol was circulated using a thermal bath. The system collected continuous measurements during both heating and cooling cycles exhibiting no hysteresis. The use of video tracking analysis software greatly reduced the measurement errors associated with measuring the time required for the meniscus to pass through the markings on the viscometer. The stability of the system was assessed by performing 38 consecutive measurements of water at 42.50 ± 0.05 °C giving an average flow time of 87.7 ± 0.3 s. A device was also implemented to repeatedly deliver a constant volume of liquid of 11.00 ± 0.03 ml leading to an average error in the viscosity of 0.04%. As an application, the system was used to measure the viscosity of two Li-ion battery electrolyte solvents from approximately 10 to 40 °C with results showing excellent agreement with viscosity values calculated using Gering's Advanced Electrolyte Model (AEM).
Estimation of Temporal Gait Parameters Using a Human Body Electrostatic Sensing-Based Method.
Li, Mengxuan; Li, Pengfei; Tian, Shanshan; Tang, Kai; Chen, Xi
2018-05-28
Accurate estimation of gait parameters is essential for obtaining quantitative information on motor deficits in Parkinson's disease and other neurodegenerative diseases, which helps determine disease progression and therapeutic interventions. Due to the demand for high accuracy, unobtrusive measurement methods such as optical motion capture systems, foot pressure plates, and other systems have been commonly used in clinical environments. However, the high cost of existing lab-based methods greatly hinders their wider usage, especially in developing countries. In this study, we present a low-cost, noncontact, and an accurate temporal gait parameters estimation method by sensing and analyzing the electrostatic field generated from human foot stepping. The proposed method achieved an average 97% accuracy on gait phase detection and was further validated by comparison to the foot pressure system in 10 healthy subjects. Two results were compared using the Pearson coefficient r and obtained an excellent consistency ( r = 0.99, p < 0.05). The repeatability of the purposed method was calculated between days by intraclass correlation coefficients (ICC), and showed good test-retest reliability (ICC = 0.87, p < 0.01). The proposed method could be an affordable and accurate tool to measure temporal gait parameters in hospital laboratories and in patients' home environments.
Mechanical Characterization of the Iter Mock-Up Insulation after Reactor Irradiation
NASA Astrophysics Data System (ADS)
Prokopec, R.; Humer, K.; Fillunger, H.; Maix, R. K.; Weber, H. W.
2010-04-01
The ITER mock-up project was launched in order to demonstrate the feasibility of an industrial impregnation process using the new cyanate ester/epoxy blend. The mock-up simulates the TF winding pack cross section by a stainless steel structure with the same dimensions as the TF winding pack at a length of 1 m. It consists of 7 plates simulating the double pancakes, each of them is wrapped with glass fiber/Kapton sandwich tapes. After stacking the 7 plates, additional insulation layers are wrapped to simulate the ground insulation. This paper presents the results of the mechanical quality tests on the mock-up pancake insulation. Tensile and short beam shear specimens were cut from the plates extracted from the mock-up and tested at 77 K using a servo-hydraulic material testing device. All tests were repeated after reactor irradiation to a fast neutron fluence of 1×1022 m-2 (E>0.1 MeV). In order to simulate the pulsed operation of ITER, tension-tension fatigue measurements were performed in the load controlled mode. Initial results show a high mechanical strength as expected from the high number of thin glass fiber layers, and an excellent homogeneity of the material.
A simple preparation of graphite/gelatin composite for electrochemical detection of dopamine.
Rajkumar, Chellakannu; Thirumalraj, Balamurugan; Chen, Shen-Ming; Chen, His-An
2017-02-01
In this study, we demonstrate a simple preparation of graphite (GR) sheets assisted with gelatin (GLN) polypeptide composite was developed for sensitive detection of dopamine (DA) sensor. The GR/GLN composite was prepared by GR powder in GLN solution (5mg/mL) via sonication process. The prepared GR/GLN composite displays well dispersion ability in biopolymer matrix and characterized via scanning electron microscope (SEM), Fourier transform infrared (FTIR) spectroscopy and electrochemical impedance spectroscopy (EIS) studies. The GR/GLN modified electrode showed an excellent electrocatalytic activity toward the oxidation of DA, suggesting that the successful formation of GR sheets crosslinked with the functional groups of GLN polypeptide. In addition, the GR/GLN modified electrode achieved a wide linear response ranging from 0.05 to 79.5μM with a detection limit of 0.0045μM. The calculated analytical sensitivity of the sensor was 1.36±0.02μAμM -1 cm -2 . Conversely, the modified electrode demonstrates a good storage stability, reproducibility and repeatability. In addition, the sensor manifests the determination of DA in human serum and urine samples for practical applications. Copyright © 2016 Elsevier Inc. All rights reserved.
Chen, Pei-Yen; Luo, Chin-Hsiang; Chen, Mei-Chin; Tsai, Feng-Jie; Chang, Nai-Fang; Shih, Ying
2011-01-01
Cobalt phthalocyanine (CoPc) films were deposited on the surface of a screen-printed carbon electrode using a simple drop coating method. The cyclic voltammogram of the resulting CoPc modified screen-printed electrode (CoPc/SPE) prepared under optimum conditions shows a well-behaved redox couple due to the (CoI/CoII) system. The CoPc/SPE surface demonstrates excellent electrochemical activity towards the oxidation of sulfur in a 0.01 mol·L−1 NaOH. A linear calibration curve with the detection limit (DL, S/N = 3) of 0.325 mg·L−1 was achieved by CoPc/SPE coupled with flow injection analysis of the sulfur concentration ranging from 4 to 1120 mg·L−1. The precision of the system response was evaluated (3.60% and 3.52% RSD for 12 repeated injections), in the range of 64 and 480 mg·L−1 sulfur. The applicability of the method was successfully demonstrated in a real sample analysis of sulfur in anti-acne creams, and good recovery was obtained. The CoPc/SPE displayed several advantages in sulfur determination including easy fabrication, high stability, and low cost. PMID:21747708
Experimental validation of Critical Temperature-Pressure theory of scuffing
NASA Astrophysics Data System (ADS)
Lee, Si C.; Chen, Huanliang
1995-07-01
A series of experiments was conducted for validating a newly developed theory of scuffing. The Critical temperature-Pressure (CTP) theory is based on the physisorption behavior of lubricants and is capable of predicting the onset of scuffing failures over a wide range of operating conditions, including the contacts operating in the boundary lubrication and in the partial elastohydrodynamic lubrication (EHL) regimes. According to the CTP theory, failures occur when the contact temperature exceeds a certain critical value which is a function of the lubricant pressure generated by the hydrodynamic action of the EHL contact. A special device capable of simulating the ambient conditions of the partial EHL conjunctions (of contact temperature, pressure, and the lubricant pressure) was constructed. A ball-on-flat type wear tester was put inside a pressure vessel, completely immersed in a highly pressurized bath of mineral oil. The temperature on the flat specimen was gradually increased while the ball was slowly traversed. At a certain critical temmperature, the friction force abruptly jumped indicating the incipiency of the lubrication breakdown. This experiment was repeated for several levels of hydrostatic pressure and the corresponding critical temperatures were obtained. The test results showed an excellent correlation with the newly developed CTP theory.
Dendrite-Free Sodium-Metal Anodes for High-Energy Sodium-Metal Batteries.
Sun, Bing; Li, Peng; Zhang, Jinqiang; Wang, Dan; Munroe, Paul; Wang, Chengyin; Notten, Peter H L; Wang, Guoxiu
2018-05-31
Sodium (Na) metal is one of the most promising electrode materials for next-generation low-cost rechargeable batteries. However, the challenges caused by dendrite growth on Na metal anodes restrict practical applications of rechargeable Na metal batteries. Herein, a nitrogen and sulfur co-doped carbon nanotube (NSCNT) paper is used as the interlayer to control Na nucleation behavior and suppress the Na dendrite growth. The N- and S-containing functional groups on the carbon nanotubes induce the NSCNTs to be highly "sodiophilic," which can guide the initial Na nucleation and direct Na to distribute uniformly on the NSCNT paper. As a result, the Na-metal-based anode (Na/NSCNT anode) exhibits a dendrite-free morphology during repeated Na plating and striping and excellent cycling stability. As a proof of concept, it is also demonstrated that the electrochemical performance of sodium-oxygen (Na-O 2 ) batteries using the Na/NSCNT anodes show significantly improved cycling performances compared with Na-O 2 batteries with bare Na metal anodes. This work opens a new avenue for the development of next-generation high-energy-density sodium-metal batteries. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wang, Yuting; Cheng, Jing; Yu, Suye; Alcocer, Enric Juan; Shahid, Muhammad; Wang, Ziyuan; Pan, Wei
2016-01-01
Here we report a high efficiency photocatalyst, i.e., Mn2+-doped and N-decorated ZnO nanofibers (NFs) enriched with vacancy defects, fabricated via electrospinning and a subsequent controlled annealing process. This nanocatalyst exhibits excellent visible-light photocatalytic activity and an apparent quantum efficiency up to 12.77%, which is 50 times higher than that of pure ZnO. It also demonstrates good stability and durability in repeated photocatalytic degradation experiments. A comprehensive structural analysis shows that high density of oxygen vacancies and nitrogen are introduced into the nanofibers surface. Hence, the significant enhanced visible photocatalytic properties for Mn-ZnO NFs are due to the synergetic effects of both Mn2+ doping and N decorated. Further investigations exhibit that the Mn2+-doping facilitates the formation of N-decorated and surface defects when annealing in N2 atmosphere. N doping induce the huge band gap decrease and thus significantly enhance the absorption of ZnO nanofibers in the range of visible-light. Overall, this paper provides a new approach to fabricate visible-light nanocatalysts using both doping and annealing under anoxic ambient. PMID:27600260
2017-01-01
Steam distillation is used to isolate scent of rose flowers. Rose aromatic water is commonly used in European cuisine and aromatherapy besides its use in cosmetic industry for its lovely scent. In this study, three different sampling techniques, liquid-liquid extraction (LLE), headspace technique (HS), and solid phase extraction (SPE), were compared for the analysis of volatile water-soluble compounds in commercial rose aromatic water. Some volatile water-soluble compounds of rose aromatic water were also analyzed by gas chromatography mass spectrometry (GCMS). In any case, it was concluded that one of the solid phase extraction methods led to higher recoveries for 2-phenylethyl alcohol (PEA) in the rose aromatic water than the liquid-liquid extraction and headspace technique. Liquid-liquid extraction method provided higher recovery ratios for citronellol, nerol, and geraniol than others. Ideal linear correlation coefficient values were observed by GCMS for quantitative analysis of volatile compounds (r2 ≥ 0.999). Optimized methods showed acceptable repeatability (RSDs < 5%) and excellent recovery (>95%). For compounds such as α-pinene, linalool, β-caryophyllene, α-humulene, methyl eugenol, and eugenol, the best recovery values were obtained with LLE and SPE. PMID:28791049
Organization and evolution of highly repeated satellite DNA sequences in plant chromosomes.
Sharma, S; Raina, S N
2005-01-01
A major component of the plant nuclear genome is constituted by different classes of repetitive DNA sequences. The structural, functional and evolutionary aspects of the satellite repetitive DNA families, and their organization in the chromosomes is reviewed. The tandem satellite DNA sequences exhibit characteristic chromosomal locations, usually at subtelomeric and centromeric regions. The repetitive DNA family(ies) may be widely distributed in a taxonomic family or a genus, or may be specific for a species, genome or even a chromosome. They may acquire large-scale variations in their sequence and copy number over an evolutionary time-scale. These features have formed the basis of extensive utilization of repetitive sequences for taxonomic and phylogenetic studies. Hybrid polyploids have especially proven to be excellent models for studying the evolution of repetitive DNA sequences. Recent studies explicitly show that some repetitive DNA families localized at the telomeres and centromeres have acquired important structural and functional significance. The repetitive elements are under different evolutionary constraints as compared to the genes. Satellite DNA families are thought to arise de novo as a consequence of molecular mechanisms such as unequal crossing over, rolling circle amplification, replication slippage and mutation that constitute "molecular drive". Copyright 2005 S. Karger AG, Basel.
High Productivity DRIE solutions for 3D-SiP and MEMS Volume Manufacturing
NASA Astrophysics Data System (ADS)
Puech, M.; Thevenoud, JM; Launay, N.; Arnal, N.; Godinat, P.; Andrieu, B.; Gruffat, JM
2006-04-01
Emerging 3D-SiP technologies and high volume MEMS applications require high productivity mass production DRIE systems. The Alcatel DRIE product range has recently been optimised to reach the highest process and hardware production performances. A study based on sub-micron high aspect ratio structures encountered in the most stringent 3D-SiP has been carried out. The optimization of the Bosch process parameters has resulted in ultra high silicon etch rates, with unrivalled uniformity and repeatability leading to excellent process. In parallel, most recent hardware and proprietary design optimization including vacuum pumping lines, process chamber, wafer chucks, pressure control system, gas delivery are discussed. These improvements have been monitored in a mass production environment for a mobile phone application. Field data analysis shows a significant reduction of cost of ownership thanks to increased throughput and much lower running costs. These benefits are now available for all 3D-SiP and high volume MEMS applications. The typical etched patterns include tapered trenches for CMOS imagers, through silicon via holes for die stacking, well controlled profile angle for 3D high precision inertial sensors, and large exposed area features for inkjet printer heads and Silicon microphones.
NASA Astrophysics Data System (ADS)
Zhang, Dongzhi; Jiang, Chuanxing; Tong, Jun; Zong, Xiaoqi; Hu, Wei
2018-04-01
Graphene is a potential building block for next generation electronic devices including field-effect transistors, chemical sensors, and radio frequency switches. Investigations of strain application of graphene-based films have emerged in recent years, but the challenges in synthesis and processing achieving control over its fabrication constitute the main obstacles towards device applications. This work presents an alternative approach, layer-by-layer self-assembly, allowing a controllable fabrication of graphene/polymer film strain sensor on flexible substrates of polyimide with interdigital electrodes. Carboxylated graphene and poly (diallyldimethylammonium chloride) (PDDA) were exploited to form hierarchical nanostructure due to electrostatic action. The morphology and structure of the film were inspected by using scanning electron microscopy, x-ray diffraction and Fourier transform infrared spectroscopy. The strain-sensing properties of the graphene/PDDA film sensor were investigated through tuning micrometer caliper exertion and a PC-assisted piezoresistive measurement system. Experimental result shows that the sensor exhibited not only excellent response and reversibility behavior as a function of deflection, but also good repeatability and acceptable linearity. The strain-sensing mechanism of the proposed sensor was attributed to the electrical resistance change resulted from piezoresistive effect.
Xu, Lili; Feng, Juanjuan; Li, Jubai; Liu, Xia; Jiang, Shengxiang
2012-01-01
A novel chemically bonded graphene oxide/fused-silica fiber was prepared and applied in solid-phase microextraction of six polycyclic aromatic hydrocarbons from water samples coupled with gas chromatography. It exhibited high extraction efficiency and excellent stability. Effects of extraction time, extraction temperature, ionic strength, stirring rate and desorption conditions were investigated and optimized in our work. Detection limits to the six polycyclic aromatic hydrocarbons were less than 0.08 μg/L, and their calibration curves were all linear (R(2)≥0.9954) in the range from 0.05 to 200 μg/L. Single fiber repeatability and fiber-to-fiber reproducibility were less than 6.13 and 15.87%, respectively. This novel fiber was then utilized to analyze two real water samples from the Yellow River and local waterworks, and the recoveries of samples spiked at 1 and 10 μg/L ranged from 84.48 to 118.24%. Compared with other coating materials, this graphene oxide-coated fiber showed many advantages: wide linear range, low detection limit, and good stability in acid, alkali, organic solutions and at high temperature. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Self-Rectifying Effect in Resistive Switching Memory Using Amorphous InGaZnO
NASA Astrophysics Data System (ADS)
Lee, Jin-Woo; Kwon, Hyeon-Min; Kim, Myeong-Ho; Lee, Seung-Ryul; Kim, Young-Bae; Choi, Duck-Kyun
2014-05-01
Resistance random access memory (ReRAM) has received attention as next-generation memory because of its excellent operating properties and high density integration capability as a crossbar array. However, the application of the existing ReRAM as a crossbar array may lead to crosstalk between adjacent cells due to its symmetric I- V characteristics. In this study, the self-rectifying effect of contact between amorphous In-Ga-Zn-O (a-IGZO) and TaO x was examined in a Pt/a-IGZO/TaO x /Al2O3/W structure. The experimental results show not only self-rectifying behavior but also forming-free characteristics. During the deposition of a-IGZO on the TaO x , an oxygen-rich TaO x interfacial layer was formed. The rectifying effect was observed regardless of the interface formation and is believed to be associated with Schottky contact formation between a-IGZO and TaO x . The current level remained unchanged despite repeated DC sweep cycles. The low resistance state/high resistance state ratio was about 101 at a read voltage of -0.5 V, and the rectifying ratio was about 103 at ±2 V.
Jodra, Adrián; López, Miguel Ángel; Escarpa, Alberto
2015-02-15
An electrochemical magnetoimmunosensor involving magnetic beads and disposable carbon screen-printed electrode (CSPE) for Fumonosins (FB1, FB2 and FB3) has been developed and evaluated through a certified reference material (CRM) and beer samples. Once the immunochemical reactions took place on the magnetic beads solution, they were confined on the surface of CSPE, where electrochemical detection is achieved through the addition of suitable substrate and mediator for enzymatic tracer (Horseradish peroxidase--HRP). A remarkable detection limit of 0.33 μg L(-1), outstanding repeatability and reproducibility (RSD(intraday) of 5.6% and 2.9%; RSD(interday) of 6.9% and 6.0%; both for 0 and 5 μg L(-1) FB1 respectively), and excellent accuracy with recovery rate of 85-96% showed the suggested approach to be a very suitable screening tool for the analysis of Fumonisin B1 and B2 in food samples. A simultaneous simplified calibration and analysis protocol allows a fast and reliable determination of Fumonisin in beer samples with recovery rate of 87-105%. This strategy enhanced the analytical merits of immunosensor approach towards truly disposable tools for food-safety monitoring. Copyright © 2014 Elsevier B.V. All rights reserved.
Ghaedi, Hamed; Afkhami, Abbas; Madrakian, Tayyebeh; Soltani-Felehgari, Farzaneh
2016-02-01
A new chemically modified carbon paste electrode (CMCPE) was applied to the simple, rapid, highly selective and sensitive determination of citalopram in human serum and pharmaceutical preparations using adsorptive square wave voltammetry (ASWV). The ZnO nanoparticles and multi-walled carbon nanotubes modified CPE (ZnO-MWCNT/CPE) electrode was prepared by incorporation of the ZnO nanoparticles and multi-walled carbon nanotubes (MWCNT) in carbon paste electrode. The limit of detection and the linear range were found to be 0.005 and 0.012 to 1.54μmolL(-1) of citalopram, respectively. The effects of potentially interfering substances on the determination of this compound were investigated and found that the electrode is highly selective. The proposed CMCPE was used to the determination of citalopram in human serum, urine and pharmaceutical samples. This reveals that ZnO-MWCNT/CPE shows excellent analytical performance for the determination of citalopram in terms of very low detection limit, high sensitivity, very good repeatability and reproducibility over other methods reported in the literature. Copyright © 2015. Published by Elsevier B.V.
Numerical investigations of low-density nozzle flow by solving the Boltzmann equation
NASA Technical Reports Server (NTRS)
Deng, Zheng-Tao; Liaw, Goang-Shin; Chou, Lynn Chen
1995-01-01
A two-dimensional finite-difference code to solve the BGK-Boltzmann equation has been developed. The solution procedure consists of three steps: (1) transforming the BGK-Boltzmann equation into two simultaneous partial differential equations by taking moments of the distribution function with respect to the molecular velocity u(sub z), with weighting factors 1 and u(sub z)(sup 2); (2) solving the transformed equations in the physical space based on the time-marching technique and the four-stage Runge-Kutta time integration, for a given discrete-ordinate. The Roe's second-order upwind difference scheme is used to discretize the convective terms and the collision terms are treated as source terms; and (3) using the newly calculated distribution functions at each point in the physical space to calculate the macroscopic flow parameters by the modified Gaussian quadrature formula. Repeating steps 2 and 3, the time-marching procedure stops when the convergent criteria is reached. A low-density nozzle flow field has been calculated by this newly developed code. The BGK Boltzmann solution and experimental data show excellent agreement. It demonstrated that numerical solutions of the BGK-Boltzmann equation are ready to be experimentally validated.
Antimicrobial activities of amphiphilic peptides covalently bonded to a water-insoluble resin.
Haynie, S L; Crum, G A; Doele, B A
1995-01-01
A series of polymer-bound antimicrobial peptides was prepared, and the peptides were tested for their antimicrobial activities. The immobilized peptides were prepared by a strategy that used solid-phase peptide synthesis that linked the carboxy-terminal amino acid with an ethylenediamine-modified polyamide resin (PepsynK). The acid-stable, permanent amide bond between the support and the nascent peptide renders the peptide resistant to cleavage from the support during the final acid-catalyzed deprotection step in the synthesis. Select immobilized peptides containing amino acid sequences that ranged from the naturally occurring magainin to simpler synthetic sequences with idealized secondary structures were excellent antimicrobial agents against several organisms. The immobilized peptides typically reduced the number of viable cells by > or = 5 log units. We show that the reduction in cell numbers cannot be explained by the action of a soluble component. We observed no leached or hydrolyzed peptide from the resin, nor did we observe any antimicrobial activity in soluble extracts from the immobilized peptide. The immobilized peptides were washed and reused for repeated microbial contact and killing. These results suggest that the surface actions by magainins and structurally related antimicrobial peptides are sufficient for their lethal activities. PMID:7726486
Vibro-Perception of Optical Bio-Inspired Fiber-Skin.
Li, Tao; Zhang, Sheng; Lu, Guo-Wei; Sunami, Yuta
2018-05-12
In this research, based on the principle of optical interferometry, the Mach-Zehnder and Optical Phase-locked Loop (OPLL) vibro-perception systems of bio-inspired fiber-skin are designed to mimic the tactile perception of human skin. The fiber-skin is made of the optical fiber embedded in the silicone elastomer. The optical fiber is an instinctive and alternative sensor for tactile perception with high sensitivity and reliability, also low cost and susceptibility to the magnetic interference. The silicone elastomer serves as a substrate with high flexibility and biocompatibility, and the optical fiber core serves as the vibro-perception sensor to detect physical motions like tapping and sliding. According to the experimental results, the designed optical fiber-skin demonstrates the ability to detect the physical motions like tapping and sliding in both the Mach-Zehnder and OPLL vibro-perception systems. For direct contact condition, the OPLL vibro-perception system shows better performance compared with the Mach-Zehnder vibro-perception system. However, the Mach-Zehnder vibro-perception system is preferable to the OPLL system in the indirect contact experiment. In summary, the fiber-skin is validated to have light touch character and excellent repeatability, which is highly-suitable for skin-mimic sensing.
High-throughput analysis of the satellitome illuminates satellite DNA evolution
NASA Astrophysics Data System (ADS)
Ruiz-Ruano, Francisco J.; López-León, María Dolores; Cabrero, Josefa; Camacho, Juan Pedro M.
2016-07-01
Satellite DNA (satDNA) is a major component yet the great unknown of eukaryote genomes and clearly underrepresented in genome sequencing projects. Here we show the high-throughput analysis of satellite DNA content in the migratory locust by means of the bioinformatic analysis of Illumina reads with the RepeatExplorer and RepeatMasker programs. This unveiled 62 satDNA families and we propose the term “satellitome” for the whole collection of different satDNA families in a genome. The finding that satDNAs were present in many contigs of the migratory locust draft genome indicates that they show many genomic locations invisible by fluorescent in situ hybridization (FISH). The cytological pattern of five satellites showing common descent (belonging to the SF3 superfamily) suggests that non-clustered satDNAs can become into clustered through local amplification at any of the many genomic loci resulting from previous dissemination of short satDNA arrays. The fact that all kinds of satDNA (micro- mini- and satellites) can show the non-clustered and clustered states suggests that all these elements are mostly similar, except for repeat length. Finally, the presence of VNTRs in bacteria, showing similar properties to non-clustered satDNAs in eukaryotes, suggests that this kind of tandem repeats show common properties in all living beings.
Ganiyu-Dada, Z; Bowcock, S
2011-12-01
Repeating normal laboratory tests can waste resources. This study aimed to quantify unnecessary repeat haematinic tests taken from the elderly in a district general hospital. Haematinic tests (ferritin, B12, serum folate) from patients age ≥ 70 years were reviewed for repeat tests during an 8-week period. Questionnaires were given to doctors to establish when the considered repeating a 'borderline low normal' result to be clinically justifiable. 7.7% of all haematinic tests were repeat tests and of these, the majority (83%) was performed following a previously normal result. Thirteen of 24 doctors believed repeating a normal result at the bottom of the normal range ('borderline low normal') was justifiable. After excluding 'borderline low normal' results, 6.0% (at minimum) of repeat tests were done following a previous normal result and were unnecessary. This audit showed that there are a significant number of unnecessary repeat haematinic tests being performed. © 2011 Blackwell Publishing Ltd.
Effect of repeated Ribavirin treatment on grapevine viruses.
Komínek, P; Komínková, M; Jandová, B
The effect of Ribavirin treatment for the chemotherapy of several grapevine viruses was evaluated. Four grapevine cultivars were repeatedly treated with Ribavirin in two different concentrations and with three different lengths of treatment. Repeating the Ribavirin treatment always had a significant effect on the number of healthy grapevine plants obtained. Ribavirin concentration and length of exposure showed a significant difference in sanitation of the Grapevine rupestris stem pitting-associated virus. During sanitation of the Grapevine Pinot gris virus and Grapevine fleck virus, those two factors did not show significant differences in the elimination of grapevine viruses.
Evolution of Protein Domain Repeats in Metazoa
Schüler, Andreas; Bornberg-Bauer, Erich
2016-01-01
Repeats are ubiquitous elements of proteins and they play important roles for cellular function and during evolution. Repeats are, however, also notoriously difficult to capture computationally and large scale studies so far had difficulties in linking genetic causes, structural properties and evolutionary trajectories of protein repeats. Here we apply recently developed methods for repeat detection and analysis to a large dataset comprising over hundred metazoan genomes. We find that repeats in larger protein families experience generally very few insertions or deletions (indels) of repeat units but there is also a significant fraction of noteworthy volatile outliers with very high indel rates. Analysis of structural data indicates that repeats with an open structure and independently folding units are more volatile and more likely to be intrinsically disordered. Such disordered repeats are also significantly enriched in sites with a high functional potential such as linear motifs. Furthermore, the most volatile repeats have a high sequence similarity between their units. Since many volatile repeats also show signs of recombination, we conclude they are often shaped by concerted evolution. Intriguingly, many of these conserved yet volatile repeats are involved in host-pathogen interactions where they might foster fast but subtle adaptation in biological arms races. Key Words: protein evolution, domain rearrangements, protein repeats, concerted evolution. PMID:27671125
The evolution of filamin – A protein domain repeat perspective
Light, Sara; Sagit, Rauan; Ithychanda, Sujay S.; Qin, Jun; Elofsson, Arne
2013-01-01
Particularly in higher eukaryotes, some protein domains are found in tandem repeats, performing broad functions often related to cellular organization. For instance, the eukaryotic protein filamin interacts with many proteins and is crucial for the cytoskeleton. The functional properties of long repeat domains are governed by the specific properties of each individual domain as well as by the repeat copy number. To provide better understanding of the evolutionary and functional history of repeating domains, we investigated the mode of evolution of the filamin domain in some detail. Among the domains that are common in long repeat proteins, sushi and spectrin domains evolve primarily through cassette tandem duplications while scavenger and immunoglobulin repeats appear to evolve through clustered tandem duplications. Additionally, immunoglobulin and filamin repeats exhibit a unique pattern where every other domain shows high sequence similarity. This pattern may be the result of tandem duplications, serve to avert aggregation between adjacent domains or it is the result of functional constraints. In filamin, our studies confirm the presence of interspersed integrin binding domains in vertebrates, while invertebrates exhibit more varied patterns, including more clustered integrin binding domains. The most notable case is leech filamin, which contains a 20 repeat expansion and exhibits unique dimerization topology. Clearly, invertebrate filamins are varied and contain examples of similar adjacent integrin-binding domains. Given that invertebrate integrin shows more similarity to the weaker filamin binder, integrin β3, it is possible that the distance between integrin-binding domains is not as crucial for invertebrate filamins as for vertebrates. PMID:22414427
The evolution of filamin-a protein domain repeat perspective.
Light, Sara; Sagit, Rauan; Ithychanda, Sujay S; Qin, Jun; Elofsson, Arne
2012-09-01
Particularly in higher eukaryotes, some protein domains are found in tandem repeats, performing broad functions often related to cellular organization. For instance, the eukaryotic protein filamin interacts with many proteins and is crucial for the cytoskeleton. The functional properties of long repeat domains are governed by the specific properties of each individual domain as well as by the repeat copy number. To provide better understanding of the evolutionary and functional history of repeating domains, we investigated the mode of evolution of the filamin domain in some detail. Among the domains that are common in long repeat proteins, sushi and spectrin domains evolve primarily through cassette tandem duplications while scavenger and immunoglobulin repeats appear to evolve through clustered tandem duplications. Additionally, immunoglobulin and filamin repeats exhibit a unique pattern where every other domain shows high sequence similarity. This pattern may be the result of tandem duplications, serve to avert aggregation between adjacent domains or it is the result of functional constraints. In filamin, our studies confirm the presence of interspersed integrin binding domains in vertebrates, while invertebrates exhibit more varied patterns, including more clustered integrin binding domains. The most notable case is leech filamin, which contains a 20 repeat expansion and exhibits unique dimerization topology. Clearly, invertebrate filamins are varied and contain examples of similar adjacent integrin-binding domains. Given that invertebrate integrin shows more similarity to the weaker filamin binder, integrin β3, it is possible that the distance between integrin-binding domains is not as crucial for invertebrate filamins as for vertebrates. Copyright © 2012 Elsevier Inc. All rights reserved.
The network impact of hijacking a quantum repeater
NASA Astrophysics Data System (ADS)
Satoh, Takahiko; Nagayama, Shota; Oka, Takafumi; Van Meter, Rodney
2018-07-01
In quantum networking, repeater hijacking menaces the security and utility of quantum applications. To deal with this problem, it is important to take a measure of the impact of quantum repeater hijacking. First, we quantify the work of each quantum repeater with regards to each quantum communication. Based on this, we show the costs for repeater hijacking detection using distributed quantum state tomography and the amount of work loss and rerouting penalties caused by hijacking. This quantitative evaluation covers both purification-entanglement swapping and quantum error correction repeater networks. Naive implementation of the checks necessary for correct network operation can be subverted by a single hijacker to bring down an entire network. Fortunately, the simple fix of randomly assigned testing can prevent such an attack.
Subliminal mere exposure and explicit and implicit positive affective responses.
Hicks, Joshua A; King, Laura A
2011-06-01
Research suggests that repeated subliminal exposure to environmental stimuli enhances positive affective responses. To date, this research has primarily concentrated on the effects of repeated exposure on explicit measures of positive affect (PA). However, recent research suggests that repeated subliminal presentations may increase implicit PA as well. The present study tested this hypothesis. Participants were either subliminally primed with repeated presentations of the same stimuli or only exposed to each stimulus one time. Results confirmed predictions showing that repeated exposure to the same stimuli increased both explicit and implicit PA. Implications for the role of explicit and implicit PA in attitudinal judgements are discussed.
Yu, Hong-Wei; Jiang, Jing-Hui; Zhang, Ze; Wan, Guang-Cai; Liu, Zhi-Yong; Chang, Dong; Pan, Hong-Zhi
2017-02-15
The assembly of quantum dots (QDs) in a simply method opens up opportunities to obtain access to the full potential of assembled QDs by virtue of the collective properties of the ensembles. In this study, quantum dots CdTe and graphene (Gr) nanocomposite was constructed for the simultaneous determination of uric acid (UA) and dopamine (DA). The CdTe QDs-Gr nanocomposite was prepared by ultrasonication and was characterized with microscopic techniques. The nanocomposite modified electrode was characterized by cyclicvoltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). Due to the synergistic effects between CdTe QDs and Gr, the fabricated electrode exhibited excellent electrochemical catalytic activities, good biological compatibility and high sensitivity toward the oxidation of UA and DA. Under optimum conditions, in the co-existence system the linear calibration plots for UA and DA were obtained over the range of 3-600 μM and 1-500 μM with detection limits of 1.0 μM and 0.33 μM. The fabricated biosensor also exhibits the excellent repeatability, reproducibility, storage stability along with acceptable selectivity. Copyright © 2016. Published by Elsevier Inc.
Han, Jin Kyu; Jeon, Do Hyun; Cho, Sam Yeon; Kang, Sin Wook; Lim, Jongsun; Bu, Sang Don
2017-10-07
Recently, composite-type nanogenerators (NGs) formed from piezoelectric nanostructures and multi-walled carbon nanotubes (CNTs), have become one of the excellent candidates for future energy harvesting because of their ability to apply the excellent electrical and mechanical properties of CNTs. However, the synthesis of NG devices with a high proportion of piezoelectric materials and a low polymer content, such as of polydimethylsiloxane (PDMS), continues to be problematic. In this work, high-piezoelectric-material-content flexible films produced from Pb(Zr,Ti)O₃ (PZT)-atomically-interconnected CNTs and polytetrafluoroethylene (PTFE) are presented. Various physical and chemical characterization techniques are employed to examine the morphology and structure of the materials. The direct growth of the piezoelectric material on the CNTs, by stirring the PZT and CNT mixed solution, results in various positive effects, such as a high-quality dispersion in the polymer matrix and addition of flexoelectricity to piezoelectricity, resulting in the enhancement of the output voltage by an external mechanical force. The NGs repeatedly generate an output voltage of 0.15 V. These results present a significant step toward the application of NGs using piezoelectric nanocomposite materials.
Lu, Zhiwei; Dai, Wanlin; Liu, Baichen; Mo, Guangquan; Zhang, Junjun; Ye, Jiaping; Ye, Jianshan
2018-04-18
In this work, we report a facile and green strategy for one pot and in-situ synthesis of a dandelion-like conductive polyaniline coated gold nanoparticle nanocomposites (Au@PANI). The Au@PANI was characterized by SEM, TEM, XRD, TGA, FTIR, UV-vis and conductivity measurement, respectively. Newly-designed Au@PANI materials possessed a significantly high conductivity and strong adsorption capability. Thus, the Au@PANI modified glassy carbon electrode (GCE) was utilized for construct a novel electrochemical sensor for the simultaneous assay of Pb 2+ and Cu 2+ using square wave anodic stripping voltammetry (SWASV). Under the optimized conditions, an excellent electrochemical response in the simultaneous of Pb 2+ and Cu 2+ with detection limit of 0.003 and 0.008 μM (S/N = 3), respectively. Moreover, the prepared sensors realized an excellent reproducibility, repeatability and long term stability, as well as reliable practical assays in real water samples. Besides, the possible formation mechanism and sensing mechanism of Au@PANI nanocomposites have been discussed in detail. We believe this study provides a novel method of fabrication of noble metal nanoparticles decorated conducting polymer materials for the electrochemical sensing applications. Copyright © 2018 Elsevier Inc. All rights reserved.
Synthesis and Application of Pyrrolidone-containing Shale Inhibitors
NASA Astrophysics Data System (ADS)
Liu, Yonggui; Hou, Jie; Zhang, Yang; Yan, Jing; Song, Tao; Xu, Yongjun
2018-03-01
New generation polyamine inhibitors are amino-terminated polyethers with excellent inhibiting capabilities; they play a key role in borehole stabilization and reservoir protection. However, polyamine inhibitors are limited by their poor thermal stability, which can be attributed to the presence of ether bonds in their molecular structures. We propose a three-step synthesis approach fora novel pyrrolidone-containing polyamine inhibitor (DYNP) by introducing N-vinyl-2-pyrrolidone (NVP) on divinyloxyethane. This polyamine inhibitor exhibits an optimized molecular structure and has enhanced heat resistance. Characterizations by infrared (IR) spectroscopy and evaluation tests demonstrate several advantages of DYNP inhibitors, including excellent inhibiting capability (superior to similar materials such as polyamines), improved heat resistance (reasonable stability at temperatures up to 240°C), and good compatibility with both fresh water and salt water drilling fluids. These can be attributed to the presence of considerable amounts of amino groups in the repeating unit of DYNP molecules. The DYNP inhibitor was applied in over 20 boreholes in tight oil blocks in Daqing Oilfield to relieve hydration of formations with high shale contents. For instance, drilling in the 2033.5m horizontal section of Dragon 2 borehole was smooth, with a borehole diameter expansion ratio below 10%.
Bhatia, S; Singh Negi, M; Lakshmikumaran, M
1996-11-01
EcoRI restriction of the B. nigra rDNA recombinants, isolated from a lambda genomic library, showed that the 3.9-kb fragment corresponded to the Intergenic Spacer (IGS), which was sequenced and found to be 3,928 bp in size. Sequence and dot-matrix analyses showed that the organization of the B. nigra rDNA IGS was typical of most rDNA spacers, consisting of a central repetitive region and flanking unique sequences on either side. The repetitive region was composed of two repeat families-RF 'A' and RF 'B.' The B. nigra RF 'A' consisted of a tandem array of three full-length copies of a 106-bp sequence element. RF 'B' was composed of 66 tandemly repeated elements. Each 'B' element was only 21-bp in size and this is the smallest repeat unit identified in plant rDNA to date. The putative transcription initiation site (TIS) was identified as nucleotide position 3,110. Based on the sequence analysis it was suggested that the present organization of the repeat families was generated by successive cycles of deletions and amplifications and was being maintained by homogenization processes such as gene conversion and crossing-over.A detailed comparison of the rDNA IGS sequences of the three diploid Brassica species-namely, B. nigra, B. campestris, and B. oleracea-was carried out. First, comparisons revealed that B. campestris and B. oleracea were close to each other as the repeat families in both showed high sequence homology between each other. Second, the repeat elements in both the species were organized in an interspersed manner. Third, a 52-bp sequence, present just downstream of the repeats in B. campestris, was found to be identical to the B. oleracea repeats, thereby suggesting a common progenitor. On the other hand, in B. nigra no interspersion pattern of organization of repeats was observed. Further, the B. nigra RF 'A' was identified as distinct from the repeat families of B. campestris and B. oleracea. Based on this analysis, it was suggested that during speciation B. campestris and B. oleracea evolved in one lineage whereas B. nigra diverged into a separate lineage. The comparative analysis of the IGS helped in identifying not only conserved ancestral sequence motifs of possible functional significance such as promoters and enhancers, but also sequences which showed variation between the three diploid species and were therefore identified as species-specific sequences.
Izumi, Yuishin; Maruyama, Hirofumi; Oda, Masaya; Morino, Hiroyuki; Okada, Takayuki; Ito, Hidefumi; Sasaki, Iwao; Tanaka, Hiroyasu; Komure, Osamu; Udaka, Fukashi; Nakamura, Shigenobu; Kawakami, Hideshi
2003-01-01
We analyzed the SCA8 CTA/CTG repeat in a large group of Japanese subjects. The frequency of large alleles (85–399 CTA/CTG repeats) was 1.9% in spinocerebellar ataxia (SCA), 0.4% in Parkinson disease, 0.3% in Alzheimer disease, and 0% in a healthy control group; the frequency was significantly higher in the group with SCA than in the control group. Homozygotes for large alleles were observed only in the group with SCA. In five patients with SCA from two families, a large SCA8 CTA/CTG repeat and a large SCA6 CAG repeat coexisted. Age at onset was correlated with SCA8 repeats rather than SCA6 repeats in these five patients. In one of these families, at least one patient showed only a large SCA8 CTA/CTG repeat allele, with no large SCA6 CAG repeat allele. We speculate that the presence of a large SCA8 CTA/CTG repeat allele influences the function of channels such as α1A-voltage–dependent calcium channel through changing or aberrant splicing, resulting in the development of cerebellar ataxia, especially in homozygous patients. PMID:12545428
Izumi, Yuishin; Maruyama, Hirofumi; Oda, Masaya; Morino, Hiroyuki; Okada, Takayuki; Ito, Hidefumi; Sasaki, Iwao; Tanaka, Hiroyasu; Komure, Osamu; Udaka, Fukashi; Nakamura, Shigenobu; Kawakami, Hideshi
2003-03-01
We analyzed the SCA8 CTA/CTG repeat in a large group of Japanese subjects. The frequency of large alleles (85-399 CTA/CTG repeats) was 1.9% in spinocerebellar ataxia (SCA), 0.4% in Parkinson disease, 0.3% in Alzheimer disease, and 0% in a healthy control group; the frequency was significantly higher in the group with SCA than in the control group. Homozygotes for large alleles were observed only in the group with SCA. In five patients with SCA from two families, a large SCA8 CTA/CTG repeat and a large SCA6 CAG repeat coexisted. Age at onset was correlated with SCA8 repeats rather than SCA6 repeats in these five patients. In one of these families, at least one patient showed only a large SCA8 CTA/CTG repeat allele, with no large SCA6 CAG repeat allele. We speculate that the presence of a large SCA8 CTA/CTG repeat allele influences the function of channels such as alpha(1A)-voltage-dependent calcium channel through changing or aberrant splicing, resulting in the development of cerebellar ataxia, especially in homozygous patients.
What Children Recall about a Repeated Event When One Instance Is Different from the Others
ERIC Educational Resources Information Center
Connolly, Deborah A.; Gordon, Heidi M.; Woiwod, Dayna M.; Price, Heather L.
2016-01-01
This research examined whether a memorable and unexpected change (deviation details) presented during 1 instance of a repeated event facilitated children's memory for that instance and whether a repeated event facilitated children's memory for deviation details. In Experiments 1 and 2, 8-year-olds (N = 167) watched 1 or 4 live magic shows.…
Impact of Inclusion or Exclusion of Repeaters on Test Equating
ERIC Educational Resources Information Center
Puhan, Gautam
2011-01-01
This study examined the effect of including or excluding repeaters on the equating process and results. New forms of two tests were equated to their respective old forms using either all examinees or only the first timer examinees in the new form sample. Results showed that for both tests used in this study, including or excluding repeaters in the…
ERIC Educational Resources Information Center
Fong, Anthony; Jaquet, Karina; Finkelstein, Neal
2016-01-01
The information provided in this report shows how students perform when they repeat algebra I and how the level of improvement varies depending on initial course performance and the academic measure (course grades or CST scores). This information can help inform decisions and policies regarding whether and under what circumstances students should…
van den Broek, Walther J A A; Nelen, Marcel R; Wansink, Derick G; Coerwinkel, Marga M; te Riele, Hein; Groenen, Patricia J T A; Wieringa, Bé
2002-01-15
The mechanism of expansion of the (CTG)n repeat in myotonic dystrophy (DM1) patients and the cause of its pathobiological effects are still largely unknown. Most likely, long repeats exert toxicity at the level of nuclear RNA transport or splicing. Here, we analyse cis- and trans-acting parameters that determine repeat behaviour in novel mouse models for DM1. Our mice carry 'humanized' myotonic dystrophy protein kinase (Dmpk) allele(s) with either a (CTG)84 or a (CTG)11 repeat, inserted at the correct position into the endogenous DM locus. Unlike in the human situation, the (CTG)84 repeat in the syntenic mouse environment was relatively stable during intergenerational segregation. However, somatic tissues showed substantial repeat expansions which were progressive upon aging and prominent in kidney, and in stomach and small intestine, where it was cell-type restricted. Other tissues examined showed only marginal size changes. The (CTG)11 allele was completely stable, as anticipated. Introducing the (CTG)84 allele into an Msh3-deficient background completely blocked the somatic repeat instability. In contrast, Msh6 deficiency resulted in a significant increase in the frequency of somatic expansions. Competition of Msh3 and Msh6 for binding to Msh2 in functional complexes with different DNA mismatch-recognition specificity may explain why the somatic (CTG)n expansion rate is differentially affected by ablation of Msh3 and Msh6.
Mendez-Bermudez, Aaron; Hills, Mark; Pickett, Hilda A.; Phan, Anh Tuân; Mergny, Jean-Louis; Riou, Jean-François; Royle, Nicola J.
2009-01-01
A number of different processes that impact on telomere length dynamics have been identified but factors that affect the turnover of repeats located proximally within the telomeric DNA are poorly defined. We have identified a particular repeat type (CTAGGG) that is associated with an extraordinarily high mutation rate (20% per gamete) in the male germline. The mutation rate is affected by the length and sequence homogeneity of the (CTAGGG)n array. This level of instability was not seen with other sequence-variant repeats, including the TCAGGG repeat type that has the same composition. Telomeres carrying a (CTAGGG)n array are also highly unstable in somatic cells with the mutation process resulting in small gains or losses of repeats that also occasionally result in the deletion of the whole (CTAGGG)n array. These sequences are prone to quadruplex formation in vitro but adopt a different topology from (TTAGGG)n (see accompanying article). Interestingly, short (CTAGGG)2 oligonucleotides induce a DNA damage response (γH2AX foci) as efficiently as (TTAGGG)2 oligos in normal fibroblast cells, suggesting they recruit POT1 from the telomere. Moreover, in vitro assays show that (CTAGGG)n repeats bind POT1 more efficiently than (TTAGGG)n or (TCAGGG)n. We estimate that 7% of human telomeres contain (CTAGGG)n repeats and when present, they create additional problems that probably arise during telomere replication. PMID:19656953
Evolutionary conservation of sequence and secondary structures inCRISPR repeats
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kunin, Victor; Sorek, Rotem; Hugenholtz, Philip
Clustered Regularly Interspaced Palindromic Repeats (CRISPRs) are a novel class of direct repeats, separated by unique spacer sequences of similar length, that are present in {approx}40% of bacterial and all archaeal genomes analyzed to date. More than 40 gene families, called CRISPR-associated sequences (CAS), appear in conjunction with these repeats and are thought to be involved in the propagation and functioning of CRISPRs. It has been proposed that the CRISPR/CAS system samples, maintains a record of, and inactivates invasive DNA that the cell has encountered, and therefore constitutes a prokaryotic analog of an immune system. Here we analyze CRISPR repeatsmore » identified in 195 microbial genomes and show that they can be organized into multiple clusters based on sequence similarity. All individual repeats in any given cluster were inferred to form characteristic RNA secondary structure, ranging from non-existent to pronounced. Stable secondary structures included G:U base pairs and exhibited multiple compensatory base changes in the stem region, indicating evolutionary conservation and functional importance. We also show that the repeat-based classification corresponds to, and expands upon, a previously reported CAS gene-based classification including specific relationships between CRISPR and CAS subtypes.« less
Zha, Wei; Kruger, Stanley J; Johnson, Kevin M; Cadman, Robert V; Bell, Laura C; Liu, Fang; Hahn, Andrew D; Evans, Michael D; Nagle, Scott K; Fain, Sean B
2018-05-01
A previous study demonstrated the feasibility of using 3D radial ultrashort echo time (UTE) oxygen-enhanced MRI (UTE OE-MRI) for functional imaging of healthy human lungs. The repeatability of quantitative measures from UTE OE-MRI needs to be established prior to its application in clinical research. To evaluate repeatability of obstructive patterns in asthma and cystic fibrosis (CF) with UTE OE-MRI with isotropic spatial resolution and full chest coverage. Volunteer and patient repeatability. Eighteen human subjects (five asthma, six CF, and seven normal subjects). Respiratory-gated free-breathing 3D radial UTE (80 μs) sequence at 1.5T. Two 3D radial UTE volumes were acquired sequentially under normoxic and hyperoxic conditions. A subset of subjects underwent repeat acquisitions on either the same day or ≤15 days apart. Asthma and CF subjects also underwent spirometry. A workflow including deformable registration and retrospective lung density correction was used to compute 3D isotropic percent signal enhancement (PSE) maps. Median PSE (MPSE) and ventilation defect percent (VDP) of the lung were measured from the PSE map. The relations between MPSE, VDP, and spirometric measures were assessed using Spearman correlations. The test-retest repeatability was evaluated using Bland-Altman analysis and intraclass correlation coefficients (ICC). Ventilation measures in normal subjects (MPSE = 8.0%, VDP = 3.3%) were significantly different from those in asthma (MPSE = 6.0%, P = 0.042; VDP = 21.7%, P = 0.018) and CF group (MPSE = 4.5%, P = 0.0006; VDP = 27.2%, P = 0.002). MPSE correlated significantly with forced expiratory lung volume in 1 second percent predicted (ρ = 0.72, P = 0.017). The ICC of the test-retest VDP and MPSE were both ≥0.90. In all subject groups, an anterior/posterior gradient was observed with higher MPSE and lower VDP in the posterior compared to anterior regions (P ≤ 0.0021 for all comparisons). 3D radial UTE OE-MRI supports quantitative differentiation of diseased vs. healthy lungs using either whole lung VDP or MPSE with excellent test-retest repeatability. 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1287-1297. © 2017 International Society for Magnetic Resonance in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desseroit, M; EE DACTIM, CHU de Poitiers, Poitiers; Tixier, F
2016-06-15
Purpose: The goal of this study was to evaluate the repeatability of radiomics features (intensity, shape and heterogeneity) in both PET and low-dose CT components of test-retest FDG-PET/CT images in a prospective multicenter cohort of 74 NSCLC patients from ACRIN 6678 and a similar Merck trial. Methods: Seventy-four patients with stage III-IV NCSLC were prospectively included. The primary tumor and up to 3 additional lesions per patient were analyzed. The Fuzzy Locally Adaptive Bayesian algorithm was used to automatically delineate metabolically active volume (MAV) in PET. The 3D SlicerTM software was exploited to delineate anatomical volumes (AV) in CT. Tenmore » intensity first-order features, as well as 26 textural features and four 3D shape descriptors were calculated from tumour volumes in both modalities. The repeatability of each metric was assessed by Bland-Altman analysis. Results: One hundred and five lesions (primary tumors and nodal or distant metastases) were delineated and characterized. The MAV and AV determination had a repeatability of −1.4±11.0% and −1.2±18.7% respectively. Several shape and heterogeneity features were found to be highly or moderately repeatable (e.g., sphericity, co-occurrence entropy or intensity size-zone matrix zone percentage), whereas others were confirmed as unreliable with much higher variability (more than twice that of the corresponding volume determination). Conclusion: Our results in this large multicenter cohort with more than 100 measurements confirm the PET findings in previous studies (with <30 lesions). In addition, our study is the first to explore the repeatability of radiomics features in the low-dose CT component of PET/CT acquisitions (previous studies considered dosimetry CT, CE-CT or CBCT). Several features were identified as reliable in both PET and CT components and could be used to build prognostic models. This work has received a French government support granted to the CominLabs excellence laboratory and managed by the National Research Agency in the “Investing for the Future” program under reference ANR-10-LABX-07-01, and support from the city of Brest.« less
Urvoas, Agathe; Guellouz, Asma; Valerio-Lepiniec, Marie; Graille, Marc; Durand, Dominique; Desravines, Danielle C; van Tilbeurgh, Herman; Desmadril, Michel; Minard, Philippe
2010-11-26
Repeat proteins have a modular organization and a regular architecture that make them attractive models for design and directed evolution experiments. HEAT repeat proteins, although very common, have not been used as a scaffold for artificial proteins, probably because they are made of long and irregular repeats. Here, we present and validate a consensus sequence for artificial HEAT repeat proteins. The sequence was defined from the structure-based sequence analysis of a thermostable HEAT-like repeat protein. Appropriate sequences were identified for the N- and C-caps. A library of genes coding for artificial proteins based on this sequence design, named αRep, was assembled using new and versatile methodology based on circular amplification. Proteins picked randomly from this library are expressed as soluble proteins. The biophysical properties of proteins with different numbers of repeats and different combinations of side chains in hypervariable positions were characterized. Circular dichroism and differential scanning calorimetry experiments showed that all these proteins are folded cooperatively and are very stable (T(m) >70 °C). Stability of these proteins increases with the number of repeats. Detailed gel filtration and small-angle X-ray scattering studies showed that the purified proteins form either monomers or dimers. The X-ray structure of a stable dimeric variant structure was solved. The protein is folded with a highly regular topology and the repeat structure is organized, as expected, as pairs of alpha helices. In this protein variant, the dimerization interface results directly from the variable surface enriched in aromatic residues located in the randomized positions of the repeats. The dimer was crystallized both in an apo and in a PEG-bound form, revealing a very well defined binding crevice and some structure flexibility at the interface. This fortuitous binding site could later prove to be a useful binding site for other low molecular mass partners. Copyright © 2010 Elsevier Ltd. All rights reserved.
Ba, Hengxing; Wu, Lang; Liu, Zongyue; Li, Chunyi
2016-01-01
Tandem repeat units are only detected in the left domain of the mitochondrial DNA control region in sika deer. Previous studies showed that Japanese sika deer have more tandem repeat units than its cousins from the Asian continent and Taiwan, which often have only three repeat units. To determine the origin and evolution of these additional repeat units in Japanese sika deer, we obtained the sequence of repeat units from an expanded dataset of the control region from all sika deer lineages. The functional constraint is inferred to act on the first repeat unit because this repeat has the least sequence divergence in comparison to the other units. Based on slipped-strand mispairing mechanisms, the illegitimate elongation model could account for the addition or deletion of these additional repeat units in the Japanese sika deer population. We also report that these additional repeat units could be occurring in the internal positions of tandem repeat regions, possibly via coupling with a homogenization mechanism within and among these lineages. Moreover, the increased number of repeat units in the Japanese sika deer population could reflect a balance between mutation and selection, as well as genetic drift.
Single-port videoscopic splanchnotomy for palliation of refractory chronic pancreatitis.
Kuijpers, Michiel; Klinkenberg, Theo J; Bouma, Wobbe; Beese, Ulrich; DeJongste, Mike J; Mariani, Massimo A
2016-04-01
Interrupting the afferent signals that travel through the splanchnic nerves by multiportal thoracoscopic splanchnotomy can offer effective palliation in chronic pancreatitis. However, obtained results weaken after time, possibly necessitating repeat procedures. Given the palliative nature of this procedure, potential for iatrogenic damage should be kept at a minimum. So, in order to minimize invasiveness while optimizing repeatability, we sought to create an easily reproducible single-access port operative strategy. Four patients suffering from intractable pain due to chronic pancreatitis for >10 years (12.8 ± 5.9) underwent a single-port unilateral R5-R11 splanchnotomy. Postoperative recovery was uneventful. No operative complications were observed. All 4 patients experienced excellent pain relief with a significant improvement of Visual Analogue Scale pain scores (8.8 ± 1.0 preoperatively to 3.0 ± 1.2 postoperatively, P = 0.003). We report the first series of single-port video-assisted thoracoscopic surgical (VATS) splanchnotomy for palliation of intractable pain due to chronic pancreatitis. From this small study, single-port VATS splanchnotomy seems to be a safe and effective alternative to multiportal or open procedures. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graham, Mark W.
2015-07-28
In a manufacturing process, a need is identified and a product is created to fill this need. While design and engineering of the final product is important, the tools and fixtures that aid in the creation of the final product are just as important, if not more so. Power supplies assembled at the TA-55 PF-5 have been designed by an excellent engineering team. The task in PF-5 now is to ensure that all steps of the assembly and manufacturing process can be completed safely, reliably, and in a quality repeatable manner. One of these process steps involves soldering fine wiresmore » to an electrical connector. During the process development phase, the method of soldering included placing the power supply in a vice in order to manipulate it into a position conducive to soldering. This method is unacceptable from a reliability, repeatability, and ergonomic standpoint. To combat these issues, a fixture was designed to replace the current method. To do so, a twelve step engineering design process was used to create the fixture that would provide a solution to a multitude of problems, and increase the safety and efficiency of production.« less
Erfurt, L; Schandry, R; Rubenbauer, S; Braun, U
2014-09-25
The present study investigated the effects of repeated administration of Korodin(®), a combination of camphor and crataegus berry extract, on blood pressure and attentional functioning. This study was conducted based on a randomized, placebo-controlled, double-blind design. 54 persons participated (33 female, 21 male) with a mean age of 24.3 years. Blood pressure and body mass index were in the normal range. Participants received 20 drops of either Korodin(®) or a placebo for four times with interjacent time intervals of about 10 min. Blood pressure was measured sphygmomanometrically before and after each administration. Attentional performance was quantified by using two paper-and-pencil tests, the d2 Test of Attention and Digit Symbol Test. Greater increases in blood pressure occurred after the four Korodin(®) administrations in comparison to the four placebo administrations. The performance in two parameters of d2 Test of Attention was consistently superior after the intake of Korodin(®). The excellent tolerability and safety of Korodin(®), even after a total consumption of 80 drops, was confirmed. Copyright © 2014 Elsevier GmbH. All rights reserved.
Generating constrained randomized sequences: item frequency matters.
French, Robert M; Perruchet, Pierre
2009-11-01
All experimental psychologists understand the importance of randomizing lists of items. However, randomization is generally constrained, and these constraints-in particular, not allowing immediately repeated items-which are designed to eliminate particular biases, frequently engender others. We describe a simple Monte Carlo randomization technique that solves a number of these problems. However, in many experimental settings, we are concerned not only with the number and distribution of items but also with the number and distribution of transitions between items. The algorithm mentioned above provides no control over this. We therefore introduce a simple technique that uses transition tables for generating correctly randomized sequences. We present an analytic method of producing item-pair frequency tables and item-pair transitional probability tables when immediate repetitions are not allowed. We illustrate these difficulties and how to overcome them, with reference to a classic article on word segmentation in infants. Finally, we provide free access to an Excel file that allows users to generate transition tables with up to 10 different item types, as well as to generate appropriately distributed randomized sequences of any length without immediately repeated elements. This file is freely available from http://leadserv.u-bourgogne.fr/IMG/xls/TransitionMatrix.xls.
Development and flight test of metal-lined CFRP cryogenic tank for reusable rocket
NASA Astrophysics Data System (ADS)
Higuchi, Ken; Takeuchi, Shinsuke; Sato, Eiichi; Naruo, Yoshihiro; Inatani, Yoshifumi; Namiki, Fumiharu; Tanaka, Kohtaro; Watabe, Yoko
2005-07-01
A cryogenic tank made of carbon fiber reinforced plastic (CFRP) shell with aluminum thin liner has been designed as a liquid hydrogen (LH2) tank for an ISAS reusable launch vehicle, and the function of it has been proven by repeated flights onboard the test vehicle called reusable vehicle testing (RVT) in October 2003. The liquid hydrogen tank has to be a pressure vessel, because the fuel of the engine of the test vehicle is supplied by fuel pressure. The pressure vessel of a combination of the outer shell of CFRP for strength element at a cryogenic temperature and the inner liner of aluminum for gas barrier has shown excellent weight merit for this purpose. Interfaces such as tank outline shape, bulk capacity, maximum expected operating pressure (MEOP), thermal insulation, pipe arrangement, and measurement of data are also designed to be ready onboard. This research has many aims, not only development of reusable cryogenic composite tank but also the demonstration of repeated operation including thermal cycle and stress cycle, familiarization with test techniques of operation of cryogenic composite tanks, and the accumulation of data for future design of tanks, vehicle structures, safety evaluation, and total operation systems.
A standardized protocol for repeated social defeat stress in mice
Golden, Sam A; Covington, Herbert E; Berton, Olivier; Russo, Scott J
2011-01-01
A major impediment to novel drug development has been the paucity of animal models that accurately reflect symptoms of affective disorders. In animal models, prolonged social stress has proven to be useful in understanding the molecular mechanisms underlying affective-like disorders. When considering experimental approaches for studying depression, social defeat stress, in particular, has been shown to have excellent etiological, predictive, discriminative and face validity. Described here is a protocol whereby C57BL/6J mice that are repeatedly subjected to bouts of social defeat by a larger and aggressive CD-1 mouse results in the development of a clear depressive-like syndrome, characterized by enduring deficits in social interactions. Specifically, the protocol consists of three important stages, beginning with the selection of aggressive CD-1 mice, followed by agonistic social confrontations between the CD-1 and C57BL/6J mice, and concluding with the confirmation of social avoidance in subordinate C57BL/6J mice. The automated detection of social avoidance allows a marked increase in throughput, reproducibility and quantitative analysis. This protocol is highly adaptable, but in its most common form it requires 3–4 weeks for completion. PMID:21799487
García, G; Ríos, N; Gutiérrez, V
2015-06-01
Among Neotropical fish fauna, the South American killifish genus Austrolebias (Cyprinodontiformes: Rivulidae) constitutes an excellent model to study the genomic evolutionary processes underlying speciation events. Recently, unusually large genome size has been described in 16 species of this genus, with an average DNA content of about 5.95 ± 0.45 pg per diploid cell (mean C-value of about 2.98 pg). In the present paper we explore the possible origin of this unparallel genomic increase by means of comparative analysis of the repetitive components using NGS (454-Roche) technology in the lowest and highest Rivulidae genomes. Here, we provide the first annotated Rivulidae-repeated sequences composition and their relative repetitive fraction in both genomes. Remarkably, the genomic proportion of the moderately repetitive DNA in Austrolebias charrua genome represents approximately twice (45%) of the repetitive components of the highly related rivulinae taxon Cynopoecilus melanotaenia (25%). Present work provides evidence about the impact of the repeat families that could be distinctly proliferated among sublineages within Rivulidae fish group, explaining the great genome size differences encompassing the differentiation and speciation events in this family.
Faragher, S G; Dalgarno, L
1986-07-20
The 3' untranslated (UT) sequences of the genomic RNAs of five geographic variants of the alphavirus Ross River virus (RRV) were determined and compared with the 3' UT sequence of RRV T48, the prototype strain. Part of the 3' UT region of Getah virus, a close serological relative of RRV, was also sequenced. The RRV 3' UT region varies markedly in length between variants. Large deletions or insertions, sequence rearrangements and single nucleotide substitutions are observed. A sequence tract of 49 to 58 nucleotides, which is repeated as four blocks in the RRV T48 3' UT region, occurs only once in the 3' UT region of one RRV strain (NB5092), indicating that the existence of repeat sequence blocks is not essential for RRV replication. However, the precise sequence of the 3' proximal copy of the repeat block and its position relative to the poly(A) tail were identical in all RRV isolates examined, suggesting that it has an important role in RRV replication. Nucleotide substitutions between RRV variants are distributed non-randomly along the length of the 3' UT region. The sequence of 120 to 130 nucleotides adjacent to the poly(A) tail is strongly conserved. Getah virus RNA contains three repeat sequence blocks in the 3' UT region. These are similar in sequence to those in RRV RNA but differ in their arrangement. Homology between the RRV and Getah 3' UT sequences is greatest in the 3' proximal repeat sequence block that shows three differences in 49 nucleotides. The 3' proximal repeat in Getah RNA occurs at the same position, relative to the poly(A) tail, as in all RRV variants. The RRV and Getah virus 3' UT sequences show extensive homology in the region between the 3' proximal repeat and the poly(A) tail but, apart from the repeat blocks themselves, they show no significant homology elsewhere.
A comparison of pairs figure skaters in repeated jumps.
Sands, William A; Kimmel, Wendy L; McNeal, Jeni R; Murray, Steven Ross; Stone, Michael H
2012-01-01
Trends in pairs figure skating have shown that increasingly difficult jumps have become an essential aspect of high-level performance, especially in the latter part of a competitive program. We compared a repeated jump power index in a 60 s repeated jump test to determine the relationship of repeated jump test to competitive rank and to measure 2D hip, knee, and ankle angles and angular velocities at 0, 20, 40, and 60 s. Eighteen National Team Pairs Figure Skaters performed a 60 s repeated jump test on a large switch-mat with timing of flight and ground durations and digital video recording. Each 60-s period was divided into 6, 10-s intervals, with power indexes (W/kg) calculated for each 10-s interval. Power index by 10-s interval repeated measures ANOVAs (RMANOVA) showed that males exceeded females at all intervals, and the highest power index interval was during 10 to 20 s for both sexes. RMANOVAs of angles and angular velocities showed main effects for time only. Power index and jumping techniques among figure skaters showed rapid and steady declines over the test duration. Power index can predict approximately 50% of competitive rank variance, and sex differences in jumping technique were rare. Key pointsThe repeated jumps test can account for about 50% of the variance in pairs ranks.Changes in technique are largely due to fatigue, but the athletes were able to maintain a maximum flexion knee angle very close to the desired 90 degrees. Changes in angular velocity and jump heights occurred as expected, again probably due to fatigue.As expected from metabolic information, the athletes' power indexes peak around 20s and decline thereafter. Coaches should be aware of this time as a boundary beyond which fatigue becomes more manifest, and use careful choreographic choices to provide rest periods that are disguised as less demanding skating elements to afford recovery.The repeated jumps test may be a helpful off-ice test of power-endurance for figure skaters.
Fitzpatrick, Terry; Huang, Sui
2012-01-01
Alu repeats within human genes may potentially alter gene expression. Here, we show that 3′-UTR-located inverted Alu repeats significantly reduce expression of an AcGFP reporter gene. Mutational analysis demonstrates that the secondary structure, but not the primary nucleotide sequence, of the inverted Alu repeats is critical for repression. The expression levels and nucleocytoplasmic distribution of reporter mRNAs with or without 3′-UTR inverted Alu repeats are similar; suggesting that reporter gene repression is not due to changes in mRNA levels or mRNA nuclear sequestration. Instead, reporter gene mRNAs harboring 3′-UTR inverted Alu repeats accumulate in cytoplasmic stress granules. These findings may suggest a novel mechanism whereby 3′-UTR-located inverted Alu repeats regulate human gene expression through sequestration of mRNAs within stress granules. PMID:22688648
Biased distributions and decay of long interspersed nuclear elements in the chicken genome.
Abrusán, György; Krambeck, Hans-Jürgen; Junier, Thomas; Giordano, Joti; Warburton, Peter E
2008-01-01
The genomes of birds are much smaller than mammalian genomes, and transposable elements (TEs) make up only 10% of the chicken genome, compared with the 45% of the human genome. To study the mechanisms that constrain the copy numbers of TEs, and as a consequence the genome size of birds, we analyzed the distributions of LINEs (CR1's) and SINEs (MIRs) on the chicken autosomes and Z chromosome. We show that (1) CR1 repeats are longest on the Z chromosome and their length is negatively correlated with the local GC content; (2) the decay of CR1 elements is highly biased, and the 5'-ends of the insertions are lost much faster than their 3'-ends; (3) the GC distribution of CR1 repeats shows a bimodal pattern with repeats enriched in both AT-rich and GC-rich regions of the genome, but the CR1 families show large differences in their GC distribution; and (4) the few MIRs in the chicken are most abundant in regions with intermediate GC content. Our results indicate that the primary mechanism that removes repeats from the chicken genome is ectopic exchange and that the low abundance of repeats in avian genomes is likely to be the consequence of their high recombination rates.
Stoller, Oliver; Schindelholz, Matthias; Hunt, Kenneth J
2016-01-01
Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP-root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. All criteria for feasibility were achieved. Mean V'O2peak was 106±9% of predicted V'O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V'O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V'O2max, and allowed determination of sub-maximal ventilatory thresholds. The reliability and repeatability were found to be high. There is potential for augmented RASC to be used for exercise testing and prescription in populations with neurological impairments who would benefit from repetitive task-specific training.
Assessment of different methods to estimate bovine colostrum quality on farm.
Bartens, M-C; Drillich, M; Rychli, K; Iwersen, M; Arnholdt, T; Meyer, L; Klein-Jöbstl, D
2016-09-01
To evaluate two different hydrometers and an optical and a digital Brix refractometer for the assessment of bovine colostrum quality, in terms of accuracy and precision compared with the measurement of IgG concentrations using radial immunodiffusion (RID), and to evaluate the reliability and repeatability of the Brix refractometers. To determine reliability and repeatability, 145 colostrum samples were tested by two independent observers twice, using the optical and digital Brix refractometers. A further 193 colostrum samples from Holstein cows were collected on one commercial dairy farm at first milking and tested with two hydrometers and an optical and digital Brix refractometer. An aliquot of each sample was frozen for RID measurement of IgG concentrations and samples were classified as poor (≤50 g IgG/L) or good (>50 g IgG/L) quality colostrum. Intraclass correlation coefficients (ICC) were used to determine inter- and intra-observer reliability and repeatability. Optimised cut-off values for the four devices were determined using receiver operating characteristics (ROC) analysis with the RID results as the reference. Using these cut-offs, sensitivities and specificities for determining good quality colostrum were calculated. The ICC for inter-observer reliability was 0.98 for the optical Brix refractometer, and for intra-observer repeatability was 0.97 and 0.98 for the optical and the digital Brix refractometers, respectively. For the 193 colostrum samples, 67 (34.7%) had concentrations of IgG ≤50 g/L determined by RID. Optimised cut-off values evaluated by ROC analysis were higher for all devices compared with manufacturer reference or previously published values. Using these values, the sensitivities for the two hydrometers, and the optical and the digital Brix refractometers were 0.73, 0.71, 0.56 and 0.79, respectively; specificities were 0.72, 0.61, 0.90 and 0.69, respectively. The Brix refractometers provided the most accurate assessment of colostrum quality of the devices evaluated, and demonstrated excellent precision in terms of repeatability. To provide optimal health for newborn calves, a sufficient intake of good quality colostrum is essential. The Brix refractometers provide rapid, convenient tools for classification of colostrum quality.
Stoller, Oliver; Schindelholz, Matthias; Hunt, Kenneth J.
2016-01-01
Background Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. Methods Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP−root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. Results All criteria for feasibility were achieved. Mean V′O2peak was 106±9% of predicted V′O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V′O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). Conclusions RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V′O2max, and allowed determination of sub-maximal ventilatory thresholds. The reliability and repeatability were found to be high. There is potential for augmented RASC to be used for exercise testing and prescription in populations with neurological impairments who would benefit from repetitive task-specific training. PMID:26849137
NASA Astrophysics Data System (ADS)
Haller, John W.; Botteron, K.; Brunsden, Barry S.; Sheline, Yvette I.; Walkup, Ronald K.; Black, Kevin J.; Gado, Mokhtar; Vannier, Michael W.
1994-09-01
Goal: To estimate hippocampal volumes from in vivo 3D magnetic resonance (MR) brain images and determine inter-rater and intra- rater repeatability. Objective: The precision and repeatability of hippocampal volume estimates using stereologic measurement methods is sought. Design: Five normal control and five schizophrenic subjects were MR scanned using a MPRAGE protocol. Fixed grid stereologic methods were used to estimate hippocampal volumes on a graphics workstation. The images were preprocessed using histogram analysis to standardize 3D MR image scaling from 16 to 8 bits and image volumes were interpolated to 0.5 mm3 isotropic voxels. The following variables were constant for the repeated stereologic measures: grid size, inter-slice distance (1.5 mm), voxel dimensions (0.5 mm3), number of hippocampi measured (10), total number of measurements per rater (40), and number of raters (5). Two grid sizes were tested to determine the coefficient of error associated with the number of sampled 'hits' (approximately 140 and 280) on the hippocampus. Starting slice and grid position were randomly varied to assure unbiased volume estimates. Raters were blind to subject identity, diagnosis, and side of the brain from which the image volumes were extracted and the order of subject presentation was randomized for each of the raters. Inter- and intra-rater intraclass correlation coefficients (ICC) were determined. Results: The data indicate excellent repeatability of fixed grid stereologic hippocampal volume measures when using an inter-slice distance of 1.5 mm and a 6.25 mm2 grid (inter-rater ICCs equals 0.86 - 0.97, intra- rater ICCs equals 0.85 - 0.97). One major advantage of the current study was the use of 3D MR data which significantly improved visualization of hippocampal boundaries by providing the ability to access simultaneous orthogonal views while counting stereological marks within the hippocampus. Conclusion: Stereological estimates of 3D volumes from 2D MR sections provide an inexpensive, unbiased and efficient way of determining brain structural volumes. The high precision and repeatability demonstrated with stereological MR volumetry suggest that these methods may be efficiently used to measure small volume reductions associated with schizophrenia and other brain disorders.
Demonstration of repeatability in a high-energy-density planar shear mixing layer experiment
Merritt, Elizabeth Catherine; Doss, Forrest William; Di Stefano, Carlos A.; ...
2017-03-11
On laser-driven platforms the assumption of experiment repeatability is particularly important due to a typically low data acquisition rate that doesn’t often allow for data redundancy. If the platform is repeatable, then measurements of the repeatable dynamics from multiple experiments can be treated as measurements of the same system. In high-energy-density hydrodynamic instability experiments the interface growth is assumed to be one of the repeatable aspects of the system. In this paper we demonstrate the repeatability of the instability growth in the counter-propagating shear experiment at the OMEGA laser facility, where the instability growth is characterized by the tracer layermore » thickness or mix-width evolution. Furthermore, in our previous experiment campaigns we have assumed the instability growth was repeatable enough to identify trends, but in this work we explicitly show that the mix-width measurements for nominally identical experiments are repeatable within the measurement error bars.« less
Broda, Magdalena; Kierzek, Elzbieta; Gdaniec, Zofia; Kulinski, Tadeusz; Kierzek, Ryszard
2005-08-16
Trinucleotide repeat expansion diseases (TREDs) are correlated with elongation of CNG DNA and RNA repeats to pathological level. This paper shows, for the first time, complete data concerning thermodynamic stabilities of RNA with CNG trinucleotide repeats. Our studies include the stability of oligoribonucleotides composed of two to seven of CAG, CCG, CGG, and CUG repeats. The thermodynamic parameters of helix propagation correlated with the presence of multiple N-N mismatches within CNG RNA duplexes were also determined. Moreover, the total stability of CNG RNA hairpins, as well as the contribution of trinucleotide repeats placed only in the stem or loop regions, was evaluated. The improved thermodynamic parameters allow to predict much more accurately the thermodynamic stabilities and structures of CNG RNAs.
Srivastava, Deepika; Shanker, Asheesh
2016-12-01
Basal angiosperms or Magnoliids is an important clade of commercially important plants which mainly include spices and edible fruits. In this study, 17 chloroplast genome sequences belonging to clade Magnoliids were screened for the identification of chloroplast simple sequence repeats (cpSSRs). Simple sequence repeats or microsatellites are short stretches of DNA up to 1-6 base pair in length. These repeats are ubiquitous and play important role in the development of molecular markers and to study the mapping of traits of economic, medical or ecological interest. A total of 479 SSRs were detected, showing average density of 1 SSR/6.91 kb. Depending on the repeat units, the length of SSRs ranged from 12 to 24 bp for mono-, 12 to 18 bp for di-, 12 to 26 bp for tri-, 12 to 24 bp for tetra-, 15 bp for penta- and 18 bp for hexanucleotide repeats. Mononucleotide repeats were the most frequent (207, 43.21 %) followed by tetranucleotide repeats (130, 27.13 %). Penta- and hexanucleotide repeats were least frequent or absent in these chloroplast genomes.
NASA Astrophysics Data System (ADS)
Chung, Yongjin; Hyun, Kyu Hwan; Kwon, Yongchai
2015-12-01
A model explaining the π-conjugated electron pathway effect induced by a novel cross-linker adopted enzyme catalyst is suggested and the performance and stability of an enzymatic biofuel cell (EBC) adopting the new catalyst are evaluated. For this purpose, new terephthalaldehyde (TPA) and conventional glutaraldehyde (GA) cross-linkers are adopted on a glucose oxidase (GOx), polyethyleneimine (PEI) and carbon nanotube (CNT)(GOx/PEI/CNT) structure. GOx/PEI/CNT cross-linked by TPA (TPA/[GOx/PEI/CNT]) results in a superior EBC performance and stability to other catalysts. It is attributed to the π bonds conjugated between the aldehyde of TPA and amine of the GOx/PEI molecules. By π conjugation, electrons bonded with carbon and nitrogen are delocalized, promoting the electron transfer and catalytic activity with an excellent EBC performance. The maximum power density (MPD) of an EBC adopting TPA/[GOx/PEI/CNT] (0.66 mW cm-2) is far better than that of the other EBCs (the MPD of EBC adopting GOx/PEI/CNT is 0.40 mW cm-2). Regarding stability, the covalent bonding formed between TPA and GOx/PEI plays a critical role in preventing the denaturation of GOx molecules, leading to an excellent stability. By repeated measurements of the catalytic activity, TPA/[GOx/PEI/CNT] maintains its activity to 92% of its initial value even after five weeks.A model explaining the π-conjugated electron pathway effect induced by a novel cross-linker adopted enzyme catalyst is suggested and the performance and stability of an enzymatic biofuel cell (EBC) adopting the new catalyst are evaluated. For this purpose, new terephthalaldehyde (TPA) and conventional glutaraldehyde (GA) cross-linkers are adopted on a glucose oxidase (GOx), polyethyleneimine (PEI) and carbon nanotube (CNT)(GOx/PEI/CNT) structure. GOx/PEI/CNT cross-linked by TPA (TPA/[GOx/PEI/CNT]) results in a superior EBC performance and stability to other catalysts. It is attributed to the π bonds conjugated between the aldehyde of TPA and amine of the GOx/PEI molecules. By π conjugation, electrons bonded with carbon and nitrogen are delocalized, promoting the electron transfer and catalytic activity with an excellent EBC performance. The maximum power density (MPD) of an EBC adopting TPA/[GOx/PEI/CNT] (0.66 mW cm-2) is far better than that of the other EBCs (the MPD of EBC adopting GOx/PEI/CNT is 0.40 mW cm-2). Regarding stability, the covalent bonding formed between TPA and GOx/PEI plays a critical role in preventing the denaturation of GOx molecules, leading to an excellent stability. By repeated measurements of the catalytic activity, TPA/[GOx/PEI/CNT] maintains its activity to 92% of its initial value even after five weeks. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06703k
DRD4 dopamine receptor allelic diversity in various primate species
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adamson, M.; Higley, D.; O`Brien, S.
The DRD4 dopamine receptor is uniquely characterized by a 48 bp repeating segment within the coding region, located in exon III. Different DRD4 alleles are produced by the presence of additional 48 bp repeats, each of which adds 16 amino acids to the length of the 3rd intracytoplasmic loop of the receptor. The DRD4 receptor is therefore an intriguing candidate gene for behaviors which are influenced by dopamine function. In several human populations, DRD4 alleles with 2-8 and 10 repeats have previously been identified, and the 4 and 7 repeat alleles are the most abundant. We have determined DRD4 genotypesmore » in the following nonhuman primate species: chimpanzee N=2, pygmy chimpanzee N=2, gorilla N=4, siamang N=2, Gelada baboon N=1, gibbon N=1, orangutan (Bornean and Sumatran) N=62, spider monkey N=4, owl monkey N=1, Colobus monkey N=1, Patas monkey N=1, ruffed lemur N=1, rhesus macaque N=8, and vervet monkey N=28. The degree of DRD4 polymorphism and which DRD4 alleles were present both showed considerable variation across primate species. In contrast to the human, rhesus macaque monkeys were monomorphic. The 4 and 7 repeat allels, highly abundant in the human, may not be present in certain other primates. For example, the four spider monkeys we studied showed the 7, 8 and 9 repeat length alleles and the only gibbon we analyzed was homozygous for the 9 repeat allele (thus far not observed in the human). Genotyping of other primate species and sequencing of the individual DRD4 repeat alleles in different species may help us determine the ancestral DRD4 repeat length and identify connections between DRD4 genotype and phenotype.« less
Meconi, Alicia; Wortman, Ryan C; Wright, David K; Neale, Katie J; Clarkson, Melissa; Shultz, Sandy R; Christie, Brian R
2018-01-01
Repeated concussion is becoming increasingly recognized as a serious public health concern around the world. Moreover, there is a greater awareness amongst health professionals of the potential for repeated pediatric concussions to detrimentally alter the structure and function of the developing brain. To better study this issue, we developed an awake closed head injury (ACHI) model that enabled repeated concussions to be performed reliably and reproducibly in juvenile rats. A neurological assessment protocol (NAP) score was generated immediately after each ACHI to help quantify the cumulative effects of repeated injury on level of consciousness, and basic motor and reflexive capacity. Here we show that we can produce a repeated ACHI (4 impacts in two days) in both male and female juvenile rats without significant mortality or pain. We show that both single and repeated injuries produce acute neurological deficits resembling clinical concussion symptoms that can be quantified using the NAP score. Behavioural analyses indicate repeated ACHI acutely impaired spatial memory in the Barnes maze, and an interesting sex effect was revealed as memory impairment correlated moderately with poorer NAP score performance in a subset of females. These cognitive impairments occurred in the absence of motor impairments on the Rotarod, or emotional changes in the open field and elevated plus mazes. Cresyl violet histology and structural magnetic resonance imaging (MRI) indicated that repeated ACHI did not produce significant structural damage. MRI also confirmed there was no volumetric loss in the cortex, hippocampus, or corpus callosum of animals at 1 or 7 days post-ACHI. Together these data indicate that the ACHI model can provide a reliable, high throughput means to study the effects of concussions in juvenile rats.
Abdelhamid, Hani Nasser; Khan, M Shahnawaz; Wu, Hui-Fen
2014-05-01
The design, preparation and performance for novel UV-light absorbing (room-temperature) ionic liquid matrices (UV-RTILMs) for matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) were reported. A series of UV-RTILMs was prepared by ultrasonication of equimolar of acid (mefenamic acid) and bases (aniline (ANI), pyridine (Pyr), dimethyl aniline (DMANI) and 2-methyl picoline (2-P)). The UV-RTILMs have not only significant absorbance at the desired wavelength (337 nm of the N2 Laser), but also have available protons that can easily undergo proton transfer reactions to ionize the target molecules. The novel UV-RTILMs have the ability to ionize different and wide classes of compounds such as drugs, carbohydrate, and amino acids. The new UV-RTILMs series have been successfully and selectively applied for biosensing the lysates of pathogenic bacteria in the presence of the cell macromolecules. A new strategy for biosensing pathogens was presented via sensing the pathogens lysate in the cell suspension. The new materials can effectively detect the bacterial toxins without separation or any pretreatment. They offered excellent ionization of labile oligosaccharides with protonated peaks. They could significantly enhance the analyte signals, produce homogeneous spotting, reducing spot-to-spot variation, excellent vacuum stability, higher ion peak intensity, and wide application possibility. The physical parameters such as molar refractivity, molar volume, parachor, surface tension, density and polarizability were calculated and tabulated. The new UV-RTILMs could offer excellent reproducibility and great repeatability and they are promising matrices for wide applications on MALDI-MS. Copyright © 2014. Published by Elsevier B.V.
Emergence of Fairness in Repeated Group Interactions
NASA Astrophysics Data System (ADS)
Van Segbroeck, S.; Pacheco, J. M.; Lenaerts, T.; Santos, F. C.
2012-04-01
Often groups need to meet repeatedly before a decision is reached. Hence, most individual decisions will be contingent on decisions taken previously by others. In particular, the decision to cooperate or not will depend on one’s own assessment of what constitutes a fair group outcome. Making use of a repeated N-person prisoner’s dilemma, we show that reciprocation towards groups opens a window of opportunity for cooperation to thrive, leading populations to engage in dynamics involving both coordination and coexistence, and characterized by cycles of cooperation and defection. Furthermore, we show that this process leads to the emergence of fairness, whose level will depend on the dilemma at stake.
NASA Astrophysics Data System (ADS)
Wex, Sebastian; Mancktelow, Neil; Hawemann, Friedrich; Camacho, Alfredo; Pennacchioni, Giorgio
2014-05-01
The Musgrave Ranges in Central Australia provide excellent exposure of the shallowly south-dipping Woodroffe Thrust, which placed ~1200 Ma granulites onto amphibolite facies gneisses. This ~400 km long E-W structure developed under mid-crustal conditions during the intracratonic Petermann Orogeny around 550 Ma. From field observations and measurements, the shortening direction is constrained to be N-S and the movement sense top-to-north. Ductile deformation during this process almost entirely localized in the footwall rocks, developing a zone of mylonites, ultramylonites and sheared pseudotachylytes, several hundred metres wide, with pseudotachylyte abundance rapidly decreasing further into the footwall. In contrast, the hanging wall behaved in a predominantly brittle manner, producing significant volumes of pseudotachylyte breccia and isolated veins, but was otherwise mostly unaffected and only weakly foliated. The difference in rheological behaviour is reflected in the pseudotachylyte fabric, which is dominantly sheared in the footwall and largely unsheared in the hanging wall. Low-strain domains in the footwall show that localized shearing initiated along pseudotachylyte veins and that shear zones and mylonitic foliations were in turn exploited by subsequent pseudotachylyte veins. Neither phyllonitization nor synkinematic growth of new muscovite is observed. In contrast to models with a simple brittle-to-viscous transition, these observations show that a continuous cycle of brittle fracturing and shearing is active in dry mid-crustal environments. The products of multiple earthquakes and ductile overprint, repeatedly exploiting the same structural discontinuity, are composite layers of sheared pseudotachylyte. In the Woodroffe Thrust, these layers are numerous and frequently observed parallel to the foliation in the footwall mylonites. The thickest of these sheared pseudotachylyte horizons (~15 m thick) mark the immediate contact to the hanging wall and almost entirely consist of pseudotachylyte matrix. Particularly in the footwall, but locally also in the hanging wall, shear strain can additionally be concentrated along the margins of dolerite dykes, whose mineral assemblages will be studied to determine the metamorphic conditions that were active during development of the Woodroffe Thrust.
Testing low cost OEM CO2 sensors for outdoor ecological studies
NASA Astrophysics Data System (ADS)
Macintyre, C. M.; Risk, D. A.
2011-12-01
IR (Infrared) gas sensors are used extensively in CO2 research but price and power requirement often limits low-cost distributed sensing. In the past three years, sensors have been introduced to the industrial market at prices as low as $100 US for air-handling and automotive application. These inexpensive sensors are small in size, and have low power demand making them potentially ideal for low-cost distributed deployments. However, the sensors are only tested and calibrated for indoor use and for industrial standards and may not show their true potential for outdoor ecological studies. This poster summarizes the results of a sensor inter-comparison test, to document functionality, response time, electrical noise, precision, and accuracy, under varying moistures and temperatures broadly representative of a wide range of outdoor settings. The three selected sensors were placed in a closed loop system with a valving system using a LiCor Li-7000 as reference, controlled by a CR1000 datalogger that controlled CO2 and moisture concentrations content within the cell on the basis of LiCor readings. To achieve different temperatures, the tests were repeated at room temperature, inside a freezer (-18°C) and incubator (40°C). The tests involved repeatedly stepping the sensors from 2000 ppm CO2 to 400 ppm CO2 in 200 ppm or 400 ppm increments, at various moisture contents, and under the various temperature regimes. Vaisala 222 and 343 sensors were also part of the test group as comparators, as both are used widely in ecological research. The OEM sensors displayed good linearity, fast response time, and results comparable to Vaisala probes. In most cases the sensors performed beyond our expectations with notably less electrical noise than the Vaisala sensors and excellent power thriftiness. Some sensors showed better response to extreme moisture and temperature conditions. Provided that suitable protective embodiments were built around them, and that they are deployed in an environment suiting their tolerance limits, most of the tested sensors would be suitable as low-cost alternatives to sensors currently being sold for outdoor ecological studies.
Inoue, Motoki; Sasaki, Makoto; Taguchi, Tetsushi
2012-01-01
Gelatins were crosslinked with organic acids and treated with alkali to impart to them endothelialization and anti-thrombogenic properties. These matrices were characterized by biochemical and physicochemical techniques. The amounts of residual amino groups in the matrices decreased with increasing crosslinker concentration. The matrices with the highest crosslinking densities showed excellent endothelial cell adhesion and proliferation. In addition, the adhesion of platelets and formation of fibrin networks on the matrices were suppressed with increasing crosslinker concentration. The matrices also exhibited excellent biodegradability, and the degradation rate decreased with increasing crosslinking density. All the organic acid-crosslinked alkali-treated gelatins showed excellent anti-thrombogenic and endothelialization properties, superior to those of glutaraldehyde-crosslinked alkali-treated gelatins. PMID:27877542
Pathways and intermediates in forced unfolding of spectrin repeats.
Altmann, Stephan M; Grünberg, Raik G; Lenne, Pierre-François; Ylänne, Jari; Raae, Arnt; Herbert, Kristina; Saraste, Matti; Nilges, Michael; Hörber, J K Heinrich
2002-08-01
Spectrin repeats are triple-helical coiled-coil domains found in many proteins that are regularly subjected to mechanical stress. We used atomic force microscopy technique and steered molecular dynamics simulations to study the behavior of a wild-type spectrin repeat and two mutants. The experiments indicate that spectrin repeats can form stable unfolding intermediates when subjected to external forces. In the simulations the unfolding proceeded via a variety of pathways. Stable intermediates were associated to kinking of the central helix close to a proline residue. A mutant stabilizing the central helix showed no intermediates in experiments, in agreement with simulation. Spectrin repeats may thus function as elastic elements, extendable to intermediate states at various lengths.
Triplet repeat RNA structure and its role as pathogenic agent and therapeutic target
Krzyzosiak, Wlodzimierz J.; Sobczak, Krzysztof; Wojciechowska, Marzena; Fiszer, Agnieszka; Mykowska, Agnieszka; Kozlowski, Piotr
2012-01-01
This review presents detailed information about the structure of triplet repeat RNA and addresses the simple sequence repeats of normal and expanded lengths in the context of the physiological and pathogenic roles played in human cells. First, we discuss the occurrence and frequency of various trinucleotide repeats in transcripts and classify them according to the propensity to form RNA structures of different architectures and stabilities. We show that repeats capable of forming hairpin structures are overrepresented in exons, which implies that they may have important functions. We further describe long triplet repeat RNA as a pathogenic agent by presenting human neurological diseases caused by triplet repeat expansions in which mutant RNA gains a toxic function. Prominent examples of these diseases include myotonic dystrophy type 1 and fragile X-associated tremor ataxia syndrome, which are triggered by mutant CUG and CGG repeats, respectively. In addition, we discuss RNA-mediated pathogenesis in polyglutamine disorders such as Huntington's disease and spinocerebellar ataxia type 3, in which expanded CAG repeats may act as an auxiliary toxic agent. Finally, triplet repeat RNA is presented as a therapeutic target. We describe various concepts and approaches aimed at the selective inhibition of mutant transcript activity in experimental therapies developed for repeat-associated diseases. PMID:21908410
Long interspersed repeated DNA (LINE) causes polymorphism at the rat insulin 1 locus.
Lakshmikumaran, M S; D'Ambrosio, E; Laimins, L A; Lin, D T; Furano, A V
1985-09-01
The insulin 1, but not the insulin 2, locus is polymorphic (i.e., exhibits allelic variation) in rats. Restriction enzyme analysis and hybridization studies showed that the polymorphic region is 2.2 kilobases upstream of the insulin 1 coding region and is due to the presence or absence of an approximately 2.7-kilobase repeated DNA element. DNA sequence determination showed that this DNA element is a member of a long interspersed repeated DNA family (LINE) that is highly repeated (greater than 50,000 copies) and highly transcribed in the rat. Although the presence or absence of LINE sequences at the insulin 1 locus occurs in both the homozygous and heterozygous states, LINE-containing insulin 1 alleles are more prevalent in the rat population than are alleles without LINEs. Restriction enzyme analysis of the LINE-containing alleles indicated that at least two versions of the LINE sequence may be present at the insulin 1 locus in different rats. Either repeated transposition of LINE sequences or gene conversion between the resident insulin 1 LINE and other sequences in the genome are possible explanations for this.
Nasir, Sadaf; Hussain, Manzar
2011-01-01
To determine the frequency of altered findings on repeat cranial tomography (CT) in patients with mild head injury along with stable neurological examination at tertiary care hospital. Cross-sectional study was done in the Department of Radiology, Liaquat National Hospital, Karachi from January 2008 to September 2010. All patients with mild head injury in terms of Glasgow Coma Scale (GCS) who underwent repeat scan without clinical or neurological deterioration in the emergency department of a tertiary care centre were included. The collected data were accordingly entered and analyzed by the principal investigator using Statistical Package for Social Sciences (SPSS) version 16.0. In all 275 patients, only 17 (6%) of the patients were found worseing on repeat CT, 120 (43.63%) scans improved, 138 (50.18%) unchanged and 17 (6.18%) worsened. None of these patients showed signs of clinical deterioration. Our results suggest that for patients with mild head injury and stable neurological examination, only 6% of them show deterioration on repeat CT, especially when patients'GCS is below 13.
Wu, Jun; Xu, Rui; Zhan, Rixing; Luo, Gaoxing; Niu, Xihua; Liu, Yi; Lee, Benjamin Tak-Kwong; Flury, Meinrad; Wong, Chun-Ho; Fok, Manson; Lau, Johnson Yiu-Nam
2016-08-01
Burn-induced hypertrophic scars are disfiguring and can be associated with severe and intractable pruritus. No effective treatment modalities are currently available for symptomatic control of pruritus for most patients. We assessed the effect of the Antipruritic Hydrogel (CQ-01) in the symptomatic treatment of severe and intractable pruritus associated with burn-induced hypertrophic scars in a prospective, multicenter, controlled trial. A pilot study was conducted in healthy adult volunteers to identify the most appropriate hydrogel formulation. A selected preparation called Chongqing No. 1 (CQ-01; a guar gum-based hydrogel impregnated with peppermint oil, menthol, and methyl salicylate by a nanoemulsion), showed an excellent symptomatic relief in an exploratory study in 2 patients with intractable pruritus. A statistically powered, prospective, multicenter, controlled study was then conducted in 74 patients to evaluate the efficacy and safety of a 24-h application of CQ-01 compared to a gel control and a negative control on three separate areas in each patient. Symptom assessment was based on our visual analog JW scale (ranging from 0 to 100) at baseline and various time points up to 7 days after application. Follow-up studies were conducted to determine the reproducibility of CQ-01 in repeated applications. Of the 74 enrolled subjects, the only observed adverse event was skin irritation reported in 6 patients (8%) and resolved shortly after gel removal. Compared to the baseline, the gauze negative control had a mean JW score reduction of 7; while the gel control and CQ-01 had a drop of 18 (p<0.001) and 36 (p<0.001), respectively. The CQ-01 clinical effect was significant for up to 3 days and waned slowly from 3 to 7 days. There was no statistical correlation between the treatment response and any of the demographic, patient or burn-related factors. Further studies showed a trend that repeated applications might be more effective, suggesting the absence of tachyphylaxis. This prospective, multicenter, controlled study showed that this novel hydrogel CQ-01 is safe and provides significant symptomatic relief for severe and intractable pruritus associated with hypertrophic scars, an unmet medical need for these patients. This effect is independent of the etiology of the burn trauma, extent of the scarring, and duration of the scar formation. Copyright © 2016. Published by Elsevier Ltd.
2012-01-01
The analysis of the dissolved organic fraction of hydrothermal fluids has been considered a real challenge due to sampling difficulties, complexity of the matrix, numerous interferences and the assumed ppb concentration levels. The present study shows, in a qualitative approach, that Stir Bar Sorptive Extraction (SBSE) followed by Thermal Desorption – Gas Chromatography – Mass Spectrometry (TD-GC-MS) is suitable for extraction of small sample volumes and detection of a wide range of volatile and semivolatile organic compounds dissolved in hydrothermal fluids. In a case study, the technique was successfully applied to fluids from the Rainbow ultramafic-hosted hydrothermal field located at 36°14’N on the Mid-Atlantic Ridge (MAR). We show that n-alkanes, mono- and poly- aromatic hydrocarbons as well as fatty acids can be easily identified and their retention times determined. Our results demonstrate the excellent repeatability of the method as well as the possibility of storing stir bars for at least three years without significant changes in the composition of the recovered organic matter. A preliminary comparative investigation of the organic composition of the Rainbow fluids showed the great potential of the method to be used for assessing intrafield variations and carrying out time series studies. All together our results demonstrate that SBSE-TD-GC-MS analyses of hydrothermal fluids will make important contributions to the understanding of geochemical processes, geomicrobiological interactions and formation of mineral deposits. PMID:23134621
Dynamic Graphics in Excel for Teaching Statistics: Understanding the Probability Density Function
ERIC Educational Resources Information Center
Coll-Serrano, Vicente; Blasco-Blasco, Olga; Alvarez-Jareno, Jose A.
2011-01-01
In this article, we show a dynamic graphic in Excel that is used to introduce an important concept in our subject, Statistics I: the probability density function. This interactive graphic seeks to facilitate conceptual understanding of the main aspects analysed by the learners.
NASA Astrophysics Data System (ADS)
Razak, N. A.; Hamida, B. A.; Irawati, N.; Habaebi, M. H.
2017-06-01
Adiabaticity is one of the essential criteria in producing good fabricated tapered fibers. Good tapered fibers can be use in sensor application such as humidity sensor, temperature sensor and refractive index sensor. In this paper, good tapering silica fiber is produced by using flame brushing technique and then, the microfiber is coated with polymer Polyaniline (PAni) to sense different type of alcohols with different concentrations. The outcome of this experiment gives excellent repeatability in the detection of alcohol sensing with a sensitivity of 0.1332 μW/% and a resolution of 3.764%. In conclusion, conducting polymer coated optical microfiber sensor for alcohol detection with low cost, effective and simple set-up was successfully achieved in this study.
Pediatric digital chest imaging.
Tarver, R D; Cohen, M; Broderick, N J; Conces, D J
1990-01-01
The Philips Computed Radiography system performs well with pediatric portable chest radiographs, handling the throughout of a busy intensive care service 24 hours a day. Images are excellent and routinely provide a conventional (unenhanced) image and an edge-enhanced image. Radiation dose is decreased by the lowered frequency of repeat examinations and the ability of the plates to respond to a much lower dose and still provide an adequate image. The high quality and uniform density of serial PCR portable radiographs greatly enhances diagnostic content of the films. Decreased resolution has not been a problem clinically. Image manipulation and electronic transfer to remote viewing stations appear to be helpful and are currently being evaluated further. The PCR system provides a marked improvement in pediatric portable chest radiology.
Yang, Xing-Xin; Zhang, Xiao-Xia; Chang, Rui-Miao; Wang, Yan-Wei; Li, Xiao-Ni
2011-01-01
A simple and reliable high performance liquid chromatography (HPLC) method has been developed for the simultaneous quantification of five major bioactive components in ‘Shu-Jin-Zhi-Tong’ capsules (SJZTC), for the purposes of quality control of this commonly prescribed traditional Chinese medicine. Under the optimum conditions, excellent separation was achieved, and the assay was fully validated in terms of linearity, precision, repeatability, stability and accuracy. The validated method was applied successfully to the determination of the five compounds in SJZTC samples from different production batches. The HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of SJZTC. PMID:29403711
Application of the boundary integral method to immiscible displacement problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Masukawa, J.; Horne, R.N.
1988-08-01
This paper presents an application of the boundary integral method (BIM) to fluid displacement problems to demonstrate its usefulness in reservoir simulation. A method for solving two-dimensional (2D), piston-like displacement for incompressible fluids with good accuracy has been developed. Several typical example problems with repeated five-spot patterns were solved for various mobility ratios. The solutions were compared with the analytical solutions to demonstrate accuracy. Singularity programming was found to be a major advantage in handling flow in the vicinity of wells. The BIM was found to be an excellent way to solve immiscible displacement problems. Unlike analytic methods, it canmore » accommodate complex boundary shapes and does not suffer from numerical dispersion at the front.« less
Balaresque, Patricia; King, Turi E; Parkin, Emma J; Heyer, Evelyne; Carvalho-Silva, Denise; Kraaijenbrink, Thirsa; de Knijff, Peter; Tyler-Smith, Chris; Jobling, Mark A
2014-01-01
The male-specific region of the human Y chromosome (MSY) contains eight large inverted repeats (palindromes), in which high-sequence similarity between repeat arms is maintained by gene conversion. These palindromes also harbor microsatellites, considered to evolve via a stepwise mutation model (SMM). Here, we ask whether gene conversion between palindrome microsatellites contributes to their mutational dynamics. First, we study the duplicated tetranucleotide microsatellite DYS385a,b lying in palindrome P4. We show, by comparing observed data with simulated data under a SMM within haplogroups, that observed heteroallelic combinations in which the modal repeat number difference between copies was large, can give rise to homoallelic combinations with zero-repeats difference, equivalent to many single-step mutations. These are unlikely to be generated under a strict SMM, suggesting the action of gene conversion. Second, we show that the intercopy repeat number difference for a large set of duplicated microsatellites in all palindromes in the MSY reference sequence is significantly reduced compared with that for nonpalindrome-duplicated microsatellites, suggesting that the former are characterized by unusual evolutionary dynamics. These observations indicate that gene conversion violates the SMM for microsatellites in palindromes, homogenizing copies within individual Y chromosomes, but increasing overall haplotype diversity among chromosomes within related groups. PMID:24610746
Chronic methadone use, poor bowel visualization and failed colonoscopy: A preliminary study
Verma, Siddharth; Fogel, Joshua; Beyda, David J; Bernstein, Brett; Notar-Francesco, Vincent; Mohanty, Smruti R
2012-01-01
AIM: To examine effects of chronic methadone usage on bowel visualization, preparation, and repeat colonoscopy. METHODS: In-patient colonoscopy reports from October, 2004 to May, 2009 for methadone dependent (MD) patients were retrospectively evaluated and compared to matched opioid naive controls (C). Strict criteria were applied to exclude patients with risk factors known to cause constipation or gastric dysmotility. Colonoscopy reports of all eligible patients were analyzed for degree of bowel visualization, assessment of bowel preparation (good, fair, or poor), and whether a repeat colonoscopy was required. Bowel visualization was scored on a 4 point scale based on multiple prior studies: excellent = 1, good = 2, fair = 3, or poor = 4. Analysis of variance (ANOVA) and Pearson χ2 test were used for data analyses. Subgroup analysis included correlation between methadone dose and colonoscopy outcomes. All variables significantly differing between MD and C groups were included in both univariate and multivariate logistic regression analyses. P values were two sided, and < 0.05 were considered statistically significant. RESULTS: After applying exclusionary criteria, a total of 178 MD patients and 115 C patients underwent a colonoscopy during the designated study period. A total of 67 colonoscopy reports for MD patients and 72 for C were included for data analysis. Age and gender matched controls were randomly selected from this population to serve as controls in a numerically comparable group. The average age for MD patients was 52.2 ± 9.2 years (range: 32-72 years) years compared to 54.6 ± 15.5 years (range: 20-81 years) for C (P = 0.27). Sixty nine percent of patients in MD and 65% in C group were males (P = 0.67). When evaluating colonoscopy reports for bowel visualization, MD patients had significantly greater percentage of solid stool (i.e., poor visualization) compared to C (40.3% vs 6.9%, P < 0.001). Poor bowel preparation (35.8% vs 9.7%, P < 0.001) and need for repeat colonoscopy (32.8% vs 12.5%, P = 0.004) were significantly higher in MD group compared to C, respectively. Under univariate analysis, factors significantly associated with MD group were presence of fecal particulate [odds ratio (OR), 3.89, 95% CI: 1.33-11.36, P = 0.01] and solid stool (OR, 13.5, 95% CI: 4.21-43.31, P < 0.001). Fair (OR, 3.82, 95% CI: 1.63-8.96, P = 0.002) and poor (OR, 8.10, 95% CI: 3.05-21.56, P < 0.001) assessment of bowel preparation were more likely to be associated with MD patients. Requirement for repeat colonoscopy was also significant higher in MD group (OR, 3.42, 95% CI: 1.44-8.13, P = 0.01). In the multivariate analyses, the only variable independently associated with MD group was presence of solid stool (OR, 7.77, 95% CI: 1.66-36.47, P = 0.01). Subgroup analysis demonstrated a general trend towards poorer bowel visualization with higher methadone dosage. ANOVA analysis demonstrated that mean methadone dose associated with presence of solid stool (poor visualization) was significantly higher compared to mean dosage for clean colon (excellent visualization, P = 0.02) or for those with liquid stool only (good visualization, P = 0.01). CONCLUSION: Methadone dependence is a risk factor for poor bowel visualization and leads to more repeat colonoscopies. More aggressive bowel preparation may be needed in MD patients. PMID:22969198
Lima, Leandro; Sinaimeri, Blerina; Sacomoto, Gustavo; Lopez-Maestre, Helene; Marchet, Camille; Miele, Vincent; Sagot, Marie-France; Lacroix, Vincent
2017-01-01
The main challenge in de novo genome assembly of DNA-seq data is certainly to deal with repeats that are longer than the reads. In de novo transcriptome assembly of RNA-seq reads, on the other hand, this problem has been underestimated so far. Even though we have fewer and shorter repeated sequences in transcriptomics, they do create ambiguities and confuse assemblers if not addressed properly. Most transcriptome assemblers of short reads are based on de Bruijn graphs (DBG) and have no clear and explicit model for repeats in RNA-seq data, relying instead on heuristics to deal with them. The results of this work are threefold. First, we introduce a formal model for representing high copy-number and low-divergence repeats in RNA-seq data and exploit its properties to infer a combinatorial characteristic of repeat-associated subgraphs. We show that the problem of identifying such subgraphs in a DBG is NP-complete. Second, we show that in the specific case of local assembly of alternative splicing (AS) events, we can implicitly avoid such subgraphs, and we present an efficient algorithm to enumerate AS events that are not included in repeats. Using simulated data, we show that this strategy is significantly more sensitive and precise than the previous version of KisSplice (Sacomoto et al. in WABI, pp 99-111, 1), Trinity (Grabherr et al. in Nat Biotechnol 29(7):644-652, 2), and Oases (Schulz et al. in Bioinformatics 28(8):1086-1092, 3), for the specific task of calling AS events. Third, we turn our focus to full-length transcriptome assembly, and we show that exploring the topology of DBGs can improve de novo transcriptome evaluation methods. Based on the observation that repeats create complicated regions in a DBG, and when assemblers try to traverse these regions, they can infer erroneous transcripts, we propose a measure to flag transcripts traversing such troublesome regions, thereby giving a confidence level for each transcript. The originality of our work when compared to other transcriptome evaluation methods is that we use only the topology of the DBG, and not read nor coverage information. We show that our simple method gives better results than Rsem-Eval (Li et al. in Genome Biol 15(12):553, 4) and TransRate (Smith-Unna et al. in Genome Res 26(8):1134-1144, 5) on both real and simulated datasets for detecting chimeras, and therefore is able to capture assembly errors missed by these methods.
Scoring Tools for the Analysis of Infant Respiratory Inductive Plethysmography Signals.
Robles-Rubio, Carlos Alejandro; Bertolizio, Gianluca; Brown, Karen A; Kearney, Robert E
2015-01-01
Infants recovering from anesthesia are at risk of life threatening Postoperative Apnea (POA). POA events are rare, and so the study of POA requires the analysis of long cardiorespiratory records. Manual scoring is the preferred method of analysis for these data, but it is limited by low intra- and inter-scorer repeatability. Furthermore, recommended scoring rules do not provide a comprehensive description of the respiratory patterns. This work describes a set of manual scoring tools that address these limitations. These tools include: (i) a set of definitions and scoring rules for 6 mutually exclusive, unique patterns that fully characterize infant respiratory inductive plethysmography (RIP) signals; (ii) RIPScore, a graphical, manual scoring software to apply these rules to infant data; (iii) a library of data segments representing each of the 6 patterns; (iv) a fully automated, interactive formal training protocol to standardize the analysis and establish intra- and inter-scorer repeatability; and (v) a quality control method to monitor scorer ongoing performance over time. To evaluate these tools, three scorers from varied backgrounds were recruited and trained to reach a performance level similar to that of an expert. These scorers used RIPScore to analyze data from infants at risk of POA in two separate, independent instances. Scorers performed with high accuracy and consistency, analyzed data efficiently, had very good intra- and inter-scorer repeatability, and exhibited only minor confusion between patterns. These results indicate that our tools represent an excellent method for the analysis of respiratory patterns in long data records. Although the tools were developed for the study of POA, their use extends to any study of respiratory patterns using RIP (e.g., sleep apnea, extubation readiness). Moreover, by establishing and monitoring scorer repeatability, our tools enable the analysis of large data sets by multiple scorers, which is essential for longitudinal and multicenter studies.
Six-month Longitudinal Comparison of a Portable Tablet Perimeter With the Humphrey Field Analyzer.
Prea, Selwyn Marc; Kong, Yu Xiang George; Mehta, Aditi; He, Mingguang; Crowston, Jonathan G; Gupta, Vinay; Martin, Keith R; Vingrys, Algis J
2018-06-01
To establish the medium-term repeatability of the iPad perimetry app Melbourne Rapid Fields (MRF) compared to Humphrey Field Analyzer (HFA) 24-2 SITA-standard and SITA-fast programs. Multicenter longitudinal observational clinical study. Sixty patients (stable glaucoma/ocular hypertension/glaucoma suspects) were recruited into a 6-month longitudinal clinical study with visits planned at baseline and at 2, 4, and 6 months. At each visit patients undertook visual field assessment using the MRF perimetry application and either HFA SITA-fast (n = 21) or SITA-standard (n = 39). The primary outcome measure was the association and repeatability of mean deviation (MD) for the MRF and HFA tests. Secondary measures were the point-wise threshold and repeatability for each test, as well as test time. MRF was similar to SITA-fast in speed and significantly faster than SITA-standard (MRF 4.6 ± 0.1 minutes vs SITA-fast 4.3 ± 0.2 minutes vs SITA-standard 6.2 ± 0.1 minutes, P < .001). Intraclass correlation coefficients (ICC) between MRF and SITA-fast for MD at the 4 visits ranged from 0.71 to 0.88. ICC values between MRF and SITA-standard for MD ranged from 0.81 to 0.90. Repeatability of MRF MD outcomes was excellent, with ICC for baseline and the 6-month visit being 0.98 (95% confidence interval: 0.96-0.99). In comparison, ICC at 6-month retest for SITA-fast was 0.95 and SITA-standard 0.93. Fewer points changed with the MRF, although for those that did, the MRF gave greater point-wise variability than did the SITA tests. MRF correlated strongly with HFA across 4 visits over a 6-month period, and has good test-retest reliability. MRF is suitable for monitoring visual fields in settings where conventional perimetry is not readily accessible. Copyright © 2018 Elsevier Inc. All rights reserved.
Padayachy, Llewellyn C; Padayachy, Vaishali; Galal, Ushma; Gray, Rebecca; Fieggen, A Graham
2016-10-01
The aim of this study was to investigate the relationship between optic nerve sheath diameter (ONSD) measurement and invasively measured intracranial pressure (ICP) in children. ONSD measurement was performed prior to invasive measurement of ICP. The mean binocular ONSD measurement was compared to the ICP reading. Physiological variables including systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), pulse rate, temperature, respiratory rate and end tidal carbon dioxide (ETCO2) level were recorded at the time of ONSD measurement. Diagnostic accuracy analysis was performed at various ICP thresholds and repeatability, intra- and inter-observer variability, correlation between measurements in different imaging planes as well the relationship over the entire patient cohort were examined in part I of this study. Data from 174 patients were analysed. Repeatability and intra-observer variability were excellent (α = 0.97-0.99). Testing for inter-observer variability revealed good correlation (r = 0.89, p < 0.001). Imaging in the sagittal plane demonstrated a slightly better correlation with ICP (r = 0.66, p < 0.001). The ONSD measurement with the best diagnostic accuracy for detecting an ICP ≥ 20 mmHg over the entire patient cohort was 5.5 mm, sensitivity 93.2 %, specificity 74 % and odds ratio (OR) of 39.3. Transorbital ultrasound measurement of the OSND is a reliable and reproducible technique, demonstrating a good relationship with ICP and high diagnostic accuracy for detecting raised ICP.
Piñero, David P; Plaza, Ana Belén; Alió, Jorge L
2008-01-01
To determine the interchangeability of 2 anterior segment imaging systems: a very-high-frequency (VHF) ultrasound scanning system (Artemis 2, Ultralink LLC) and an optical coherence tomography (OCT) system (Visante, Zeiss). Vissum Instituto Oftalmologico de Alicante, Alicante, Spain. This study comprised 20 eyes without pathology or previous surgery. The anterior chamber depth (ACD), central corneal thickness (CCT), angle-to-angle distance (ATA), and the iridocorneal angle size (IAS) at the 0-degree and 180-degree positions were measured with 2 imaging techniques: VHF ultrasound scanning and OCT. Analysis of agreement and interchangeability was performed by the Bland and Altman method. In addition, each measurement was performed 3 times consecutively to determine intrasession repeatability by means of the coefficient of variation (CV) and the intraclass correlation coefficient (ICC). No statistically significant differences were found between imaging techniques in ACD, CCT, or ATA (P>.40). The ranges of agreement were 0.20 mm, 16.11 mum, and 0.80 mm for ACD, CCT, and ATA, respectively. Regarding IAS, no statistically significant differences were found in the nasal (P = .78) or temporal (P = .63) measurements between devices. However, the range of agreement for nasal (14.3 degrees) and temporal (14.90 degrees) values was relevant, indicating the 2 techniques cannot be used interchangeably for IAS measurement. Excellent intrasession repeatability scores were obtained (CV and ICC). The Artemis 2 and the Visante OCT systems provide equivalent and repeatable measurements of the ACD, CCT, and ATA and can be used interchangeably for these purposes.
Lee, Ying Li; Chien, Tsai Feng; Kuo, Ming Chuan; Chang, Polun
2014-01-01
This study aims to understand the relationship between participating nurses' motivation, achievement and satisfaction before and after they learned to program in Excel Visual Basic for Applications (Excel VBA). We held a workshop to train nurses in developing simple Excel VBA information systems to support their clinical or administrative practices. Before and after the workshop, the participants were evaluated on their knowledge of Excel VBA, and a questionnaire was given to survey their learning motivation and satisfaction. Statistics softwares Winsteps and SPSS were used for data analysis. Results show that the participants are more knowledgeable about VBA as well as more motivated in learning VBA after the workshop. Participants were highly satisfied with the overall arrangement of the workshop and instructors, but didn't have enough confidence in promoting the application of Excel VBA themselves. In addition, we were unable to predict the participants' achievement by their demographic characteristics or pre-test motivation level.
ERIC Educational Resources Information Center
Zullo, Holly S.
2011-01-01
Card tricks based on mathematical principles can be a great way to get students interested in exploring some important mathematical ideas. In this article, the author discusses a simple spreadsheet implementation that shows students why the card trick works and allows them to explore several variations. As an added bonus, students are introduced…
Reducing the Matthew Effect: Lessons from the "ExCELL" Head Start Intervention
ERIC Educational Resources Information Center
Hindman, Annemarie H.; Erhart, Amber C.; Wasik, Barbara A.
2012-01-01
Evidence shows that the Matthew effect is a persistent problem among early education interventions. The current study examined the degree to which the "ExCELL" ("Ex"ceptional "C"oaching for "E"arly "L"anguage and "L"iteracy) language and literacy professional development intervention for…
Textbooks for Responsible Data Analysis in Excel
ERIC Educational Resources Information Center
Garrett, Nathan
2015-01-01
With 27 million users, Excel (Microsoft Corporation, Seattle, WA) is the most common business data analysis software. However, audits show that almost all complex spreadsheets have errors. The author examined textbooks to understand why responsible data analysis is taught. A purposeful sample of 10 textbooks was coded, and then compared against…
ERIC Educational Resources Information Center
Angervall, Petra
2016-01-01
The neo-liberal university not only changes systems of governance but also impacts on how subject positions are valued. These changes justify critical questions on how academics manoeuvre in academia. In this study focus is on the told experiences of 18 researchers who describe how they made an excellent career in academia. The results show that…
Singh, Gurjeet; Klar, Amar J S
2002-01-01
The mat2,3 region of the fission yeast Schizosaccharomyces pombe exhibits a phenomenon of transcriptional silencing. This region is flanked by two identical DNA sequence elements, 2.1 kb in length, present in inverted orientation: IRL on the left and IRR on the right of the silent region. The repeats do not encode any ORF. The inverted repeat DNA region is also present in a newly identified related species, which we named S. kambucha. Interestingly, the left and right repeats share perfect identity within a species, but show approximately 2% bases interspecies variation. Deletion of IRL results in variegated expression of markers inserted in the silent region, while deletion of the IRR causes their derepression. When deletions of these repeats were genetically combined with mutations in different trans-acting genes previously shown to cause a partial defect in silencing, only mutations in clr1 and clr3 showed additive defects in silencing with the deletion of IRL. The rate of mat1 switching is also affected by deletion of repeats. The IRL or IRR deletion did not cause significant derepression of the mat2 or mat3 loci. These results implicate repeats for maintaining full repression of the mat2,3 region, for efficient mat1 switching, and further support the notion that multiple pathways cooperate to silence the mat2,3 domain. PMID:12399374
Evolution and selection of Rhg1, a copy-number variant nematode-resistance locus
Lee, Tong Geon; Kumar, Indrajit; Diers, Brian W; Hudson, Matthew E
2015-01-01
The soybean cyst nematode (SCN) resistance locus Rhg1 is a tandem repeat of a 31.2 kb unit of the soybean genome. Each 31.2-kb unit contains four genes. One allele of Rhg1, Rhg1-b, is responsible for protecting most US soybean production from SCN. Whole-genome sequencing was performed, and PCR assays were developed to investigate allelic variation in sequence and copy number of the Rhg1 locus across a population of soybean germplasm accessions. Four distinct sequences of the 31.2-kb repeat unit were identified, and some Rhg1 alleles carry up to three different types of repeat unit. The total number of copies of the repeat varies from 1 to 10 per haploid genome. Both copy number and sequence of the repeat correlate with the resistance phenotype, and the Rhg1 locus shows strong signatures of selection. Significant linkage disequilibrium in the genome outside the boundaries of the repeat allowed the Rhg1 genotype to be inferred using high-density single nucleotide polymorphism genotyping of 15 996 accessions. Over 860 germplasm accessions were found likely to possess Rhg1 alleles. The regions surrounding the repeat show indications of non-neutral evolution and high genetic variability in populations from different geographic locations, but without evidence of fixation of the resistant genotype. A compelling explanation of these results is that balancing selection is in operation at Rhg1. PMID:25735447