Sample records for shows good repeatability

  1. Repeatability study of replicate crash tests: A signal analysis approach.

    PubMed

    Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason

    2017-10-03

    To provide an objective basis on which to evaluate the repeatability of vehicle crash test methods, a recently developed signal analysis method was used to evaluate correlation of sensor time history data between replicate vehicle crash tests. The goal of this study was to evaluate the repeatability of rollover crash tests performed with the Dynamic Rollover Test System (DRoTS) relative to other vehicle crash test methods. Test data from DRoTS tests, deceleration rollover sled (DRS) tests, frontal crash tests, frontal offset crash tests, small overlap crash tests, small overlap impact (SOI) crash tests, and oblique crash tests were obtained from the literature and publicly available databases (the NHTSA vehicle database and the Insurance Institute for Highway Safety TechData) to examine crash test repeatability. Signal analysis of the DRoTS tests showed that force and deformation time histories had good to excellent repeatability, whereas vehicle kinematics showed only fair repeatability due to the vehicle mounting method for one pair of tests and slightly dissimilar mass properties (2.2%) in a second pair of tests. Relative to the DRS, the DRoTS tests showed very similar or higher levels of repeatability in nearly all vehicle kinematic data signals with the exception of global X' (road direction of travel) velocity and displacement due to the functionality of the DRoTS fixture. Based on the average overall scoring metric of the dominant acceleration, DRoTS was found to be as repeatable as all other crash tests analyzed. Vertical force measures showed good repeatability and were on par with frontal crash barrier forces. Dynamic deformation measures showed good to excellent repeatability as opposed to poor repeatability seen in SOI and oblique deformation measures. Using the signal analysis method as outlined in this article, the DRoTS was shown to have the same or better repeatability of crash test methods used in government regulatory and consumer evaluation test protocols.

  2. Comparison of Repeatability and Agreement between Swept-Source Optical Biometry and Dual-Scheimpflug Topography.

    PubMed

    Jung, Soyeon; Chin, Hee Seung; Kim, Na Rae; Lee, Kang Won; Jung, Ji Won

    2017-01-01

    To assess the repeatability and agreement of parameters obtained with two biometers and to compare the predictability. Biometry was performed on 101 eyes with cataract using the IOLMaster 700 and the Galilei G6. Three measurements were obtained per eye with each device, and repeatability was evaluated. The axial length (AL), anterior chamber depth (ACD), keratometry (K), white-to-white (WTW) corneal diameter, central corneal thickness (CCT), and lens thickness (LT) were measured and postoperative predictability was compared. Measurements could not be obtained with the IOLMaster 700 in one eye and in seven eyes with the Galilei G6 due to dense cataract. Both the IOLMaster 700 and Galilei G6 showed good repeatability, although the IOLMaster 700 showed better repeatability than the Galilei G6. There were no statistically significant differences in AL, ACD, steepest K, WTW, and LT ( P > 0.050), although flattest K, mean K, and CCT differed ( P < 0.050). The proportion of eyes with an absolute prediction error within 0.5 D was 85.0% for the IOLMaster 700 and was 80.0% for the Galilei G6 based on the SRK/T formula. Two biometers showed high repeatability and relatively good agreements. The swept-source optical biometer demonstrated better repeatability, penetration, and an overall lower prediction error.

  3. Adaptive play stabilizes cooperation in continuous public goods games

    NASA Astrophysics Data System (ADS)

    Wu, Te; Wang, Long

    2018-04-01

    We construct a model to study the effects of repeated interaction on the evolution of cooperation in continuous public goods games. Instead of preassigning the duration of repeatedness, the likelihood of group entering next round interaction is positively dependent on the group's current cooperativeness. Meanwhile, when the disturbance happens, the interaction terminates. Under rare mutations, we show that such adaptive play can lead to the dominance of full cooperative state for weak disturbance. For fairly strong disturbance, all-or-none cooperative states share higher fractions of time in the long run, results similar to the ones reported in the study (Pinheiro et al., 2014) while differing from the ones reported in another relevant study (Van Segbroeck et al., 2012), although only strategy space and way determining next round vary. Our results remain valid when groups enter next round with a given probability independent of groups' cooperativeness. In the synergic public goods games, the positive effects of repeated interactions on promoting cooperation is further strengthened. In the discounted public goods game, only very weak disturbance can lead to the dominance of full cooperative state while fairly strong disturbance can favor both full cooperative state and a partially cooperative state. Our study thus enriches the literature on the evolution of cooperation in repeated public goods games.

  4. Measurement of central corneal thickness with optical low-coherence reflectometry and ultrasound pachymetry in normal and post-femtosecond laser in situ keratomileusis eyes.

    PubMed

    Huang, Jinhai; Liao, Na; Savini, Giacomo; Li, Yuanguang; Bao, Fangjun; Yu, Ye; Yu, Ayong; Wang, Qinmei

    2015-02-01

    To determine the repeatability and reproducibility of measurements of central corneal thickness (CCT) using optical low-coherence reflectometry (Lenstar LS900; Haag Streit) in normal eyes and post-femtosecond laser in situ keratomileusis (post-FS-LASIK) eyes and evaluate their agreement with ultrasound (US) pachymetry. CCT was measured using Lenstar and US pachymetry sequentially in normal and post-FS-LASIK eyes by 2 experienced observers. Intraoperator repeatability and interoperator reproducibility were assessed by within-subject standard deviation, test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient. Paired t-tests and Bland-Altman plots were used for analyzing agreement between the 2 devices. In this study, 55 healthy subjects and 50 post-FS-LASIK patients were recruited. Test-retest repeatability of Lenstar was within 10 μm, CoV was less than 1.0%, and intraclass correlation coefficient was more than 0.9 in both normal and post-FS-LASIK groups. Mean difference between these methods was 1.4 ± 4.2 μm and -1.7 ± 5.4 μm, respectively. Moreover, measurements of CCT showed narrow 95% limits of agreement (range, normal group: -6.8 and 9.6 μm; post-FS-LASIK group: -12.4 and 8.9 μm), which implied good agreement. Measurements of CCT using Lenstar showed excellent intraoperator repeatability and interoperator reproducibility both in normal eyes and post-FS-LASIK eyes. Measurements of CCT using Lenstar and US pachymetry showed good agreement and both can be used interchangeably.

  5. An electronic nose for reliable measurement and correct classification of beverages.

    PubMed

    Mamat, Mazlina; Samad, Salina Abdul; Hannan, Mahammad A

    2011-01-01

    This paper reports the design of an electronic nose (E-nose) prototype for reliable measurement and correct classification of beverages. The prototype was developed and fabricated in the laboratory using commercially available metal oxide gas sensors and a temperature sensor. The repeatability, reproducibility and discriminative ability of the developed E-nose prototype were tested on odors emanating from different beverages such as blackcurrant juice, mango juice and orange juice, respectively. Repeated measurements of three beverages showed very high correlation (r > 0.97) between the same beverages to verify the repeatability. The prototype also produced highly correlated patterns (r > 0.97) in the measurement of beverages using different sensor batches to verify its reproducibility. The E-nose prototype also possessed good discriminative ability whereby it was able to produce different patterns for different beverages, different milk heat treatments (ultra high temperature, pasteurization) and fresh and spoiled milks. The discriminative ability of the E-nose was evaluated using Principal Component Analysis and a Multi Layer Perception Neural Network, with both methods showing good classification results.

  6. An Electronic Nose for Reliable Measurement and Correct Classification of Beverages

    PubMed Central

    Mamat, Mazlina; Samad, Salina Abdul; Hannan, Mahammad A.

    2011-01-01

    This paper reports the design of an electronic nose (E-nose) prototype for reliable measurement and correct classification of beverages. The prototype was developed and fabricated in the laboratory using commercially available metal oxide gas sensors and a temperature sensor. The repeatability, reproducibility and discriminative ability of the developed E-nose prototype were tested on odors emanating from different beverages such as blackcurrant juice, mango juice and orange juice, respectively. Repeated measurements of three beverages showed very high correlation (r > 0.97) between the same beverages to verify the repeatability. The prototype also produced highly correlated patterns (r > 0.97) in the measurement of beverages using different sensor batches to verify its reproducibility. The E-nose prototype also possessed good discriminative ability whereby it was able to produce different patterns for different beverages, different milk heat treatments (ultra high temperature, pasteurization) and fresh and spoiled milks. The discriminative ability of the E-nose was evaluated using Principal Component Analysis and a Multi Layer Perception Neural Network, with both methods showing good classification results. PMID:22163964

  7. Negative differential resistance in GaN tunneling hot electron transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Zhichao; Nath, Digbijoy; Rajan, Siddharth

    Room temperature negative differential resistance is demonstrated in a unipolar GaN-based tunneling hot electron transistor. Such a device employs tunnel-injected electrons to vary the electron energy and change the fraction of reflected electrons, and shows repeatable negative differential resistance with a peak to valley current ratio of 7.2. The device was stable when biased in the negative resistance regime and tunable by changing collector bias. Good repeatability and double-sweep characteristics at room temperature show the potential of such device for high frequency oscillators based on quasi-ballistic transport.

  8. [Standard sample preparation method for quick determination of trace elements in plastic].

    PubMed

    Yao, Wen-Qing; Zong, Rui-Long; Zhu, Yong-Fa

    2011-08-01

    Reference sample was prepared by masterbatch method, containing heavy metals with known concentration of electronic information products (plastic), the repeatability and precision were determined, and reference sample preparation procedures were established. X-Ray fluorescence spectroscopy (XRF) analysis method was used to determine the repeatability and uncertainty in the analysis of the sample of heavy metals and bromine element. The working curve and the metrical methods for the reference sample were carried out. The results showed that the use of the method in the 200-2000 mg x kg(-1) concentration range for Hg, Pb, Cr and Br elements, and in the 20-200 mg x kg(-1) range for Cd elements, exhibited a very good linear relationship, and the repeatability of analysis methods for six times is good. In testing the circuit board ICB288G and ICB288 from the Mitsubishi Heavy Industry Company, results agreed with the recommended values.

  9. Simulated Keratometry Repeatability in Subjects with & without Down Syndrome

    PubMed Central

    Ravikumar, Ayeswarya; Marsack, Jason D.; Benoit, Julia S.; Anderson, Heather A.

    2016-01-01

    Purpose To assess the repeatability of simulated keratometry measures obtained with Zeiss Atlas topography for subjects with and without Down syndrome (DS). Methods Corneal topography was attempted on 140 subjects with DS and 138 controls (aged 7 to 59 years). Subjects who had at least 3 measures in each eye were included in analysis (DS: n=140 eyes (70 subjects) and controls: n=264 eyes (132 subjects)). For each measurement the steep corneal power (K), corneal astigmatism, flat K orientation, power vector representation of astigmatism (J0, J45), and astigmatic dioptric difference were determined for each measurement (collectively termed keratometry values here). For flat K orientation comparisons, only eyes with >0.50 DC of astigmatism were included (DS: n=131 eyes (68 subjects) and control: n=217 eyes (119 subjects)). Repeatability was assessed using 1) group mean variability (average standard deviation (SD) across subjects), 2) coefficient of repeatability (COR) 3) coefficient of variation (COV), and 4) intraclass correlation coefficient (ICC). Results The keratometry values showed good repeatability as evidenced by low group mean variability for DS vs control eyes (≤0.26D vs ≤0.09D for all dioptric values; 4.51° vs 3.16° for flat K orientation); however, the group mean variability was significantly higher in DS eyes than control eyes for all parameters (p≤0.03). On average, group mean variability was 2.5× greater in the DS eyes compared to control eyes across the keratometry values. Other metrics of repeatability also indicated good repeatability for both populations for each keratometry value, although repeatability was always better in the control eyes. Conclusions DS eyes showed more variability (on average: 2.5×) compared to controls for all keratometry values. Although differences were statistically significant, on average 91% of DS eyes had variability ≤0.50D for steep K and astigmatism, and 75% of DS eyes had variability ≤5 degrees for flat K orientation. PMID:27741083

  10. The role of feedback and differences between good and poor decoders in a repeated word reading paradigm in first grade.

    PubMed

    van Gorp, Karly; Segers, Eliane; Verhoeven, Ludo

    2017-04-01

    The direct, retention, and transfer effects of repeated word and pseudoword reading were studied in a pretest, training, posttest, retention design. First graders (48 good readers, 47 poor readers) read 25 CVC words and 25 CVC pseudowords in ten repeated word reading sessions, preceded and followed by a transfer task with a different set of items. Two weeks after training, trained items were assessed again in a retention test. Participants either received phonics feedback, in which each word was spelled out and repeated; word feedback, in which each word was repeated; or no feedback. During the training, both good and poor readers improved in accuracy and speed. The increase in speed was stronger for poor readers than for good readers. The good readers demonstrated a stronger increase for pseudowords than for words. This increase in speed was most prominent in the first four sessions. Two weeks after training, the levels of accuracy and speed were retained. Furthermore, transfer effects on speed were found for pseudowords in both groups of readers. Good readers performed most accurately during the training when they received no feedback while poor readers performed most accurately during the training with the help of phonics feedback. However, feedback did not differentiate for reading speed or for effects after the training. The effects of repeated word reading were found to be stronger for poor readers than for good readers. Moreover, these effects were found to be stronger for pseudowords than for words. This indicates that repeated word reading can be seen as an important trigger for the improvement of decoding skills.

  11. Measuring joint kinematics of treadmill walking and running: Comparison between an inertial sensor based system and a camera-based system.

    PubMed

    Nüesch, Corina; Roos, Elena; Pagenstert, Geert; Mündermann, Annegret

    2017-05-24

    Inertial sensor systems are becoming increasingly popular for gait analysis because their use is simple and time efficient. This study aimed to compare joint kinematics measured by the inertial sensor system RehaGait® with those of an optoelectronic system (Vicon®) for treadmill walking and running. Additionally, the test re-test repeatability of kinematic waveforms and discrete parameters for the RehaGait® was investigated. Twenty healthy runners participated in this study. Inertial sensors and reflective markers (PlugIn Gait) were attached according to respective guidelines. The two systems were started manually at the same time. Twenty consecutive strides for walking and running were recorded and each software calculated sagittal plane ankle, knee and hip kinematics. Measurements were repeated after 20min. Ensemble means were analyzed calculating coefficients of multiple correlation for waveforms and root mean square errors (RMSE) for waveforms and discrete parameters. After correcting the offset between waveforms, the two systems/models showed good agreement with coefficients of multiple correlation above 0.950 for walking and running. RMSE of the waveforms were below 5° for walking and below 8° for running. RMSE for ranges of motion were between 4° and 9° for walking and running. Repeatability analysis of waveforms showed very good to excellent coefficients of multiple correlation (>0.937) and RMSE of 3° for walking and 3-7° for running. These results indicate that in healthy subjects sagittal plane joint kinematics measured with the RehaGait® are comparable to those using a Vicon® system/model and that the measured kinematics have a good repeatability, especially for walking. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Coevolutionary dynamics of aspiration and strategy in spatial repeated public goods games

    NASA Astrophysics Data System (ADS)

    Wu, Te; Fu, Feng; Wang, Long

    2018-06-01

    The evolutionary dynamics remain largely unknown for spatial populations where individuals are more likely to interact repeatedly. Under this settings, individuals can make their decisions to cooperate or not based on the decisions previously adopted by others in their neighborhoods. Using repeated public goods game, we construct a spatial model and use a statistical physics approach to study the coevolutionary dynamics of aspiration and strategy. Individuals each have an aspiration towards the groups they are involved. According to the outcome of each group, individuals have assessment of whether their aspirations are satisfied. If satisfied, they cooperate next round. Otherwise, they switch to defecting. Results show threshold phenomenon for harsh collective dilemma: cooperators sticking to high levels of aspiration can prevail over defectors, while cooperators with other levels are invariably wiped out. When the collective dilemma is relaxed, cooperation is greatly facilitated by inducing a high level of diversity of aspiration. Snapshots further show the spatial patterns of how this coevolutionary process leads to the emergence of an optimal solution associated with aspiration level, whose corresponding strategy are most prevalent. This optimal solution lies in one and the highest aspiration level allowed, and depends on the intensity of the social dilemma. By removing the memory effect, our results also confirm that repeated interactions can promote cooperation, but to a limited degree.

  13. Molecular weight distribution of polysaccharides from edible seaweeds by high-performance size-exclusion chromatography (HPSEC).

    PubMed

    Gómez-Ordóñez, Eva; Jiménez-Escrig, Antonio; Rupérez, Pilar

    2012-05-15

    Biological properties of polysaccharides from seaweeds are related to their composition and structure. Many factors such as the kind of sugar, type of linkage or sulfate content of algal biopolymers exert an influence in the relationship between structure and function. Besides, the molecular weight (MW) also plays an important role. Thus, a simple, reliable and fast HPSEC method with refractive index detection was developed and optimized for the MW estimation of soluble algal polysaccharides. Chromatogram shape and repeatability of retention time was considerably improved when sodium nitrate was used instead of ultrapure water as mobile phase. Pullulan and dextran standards of different MW were used for method calibration and validation. Also, main polysaccharide standards from brown (alginate, fucoidan, laminaran) and red seaweeds (kappa- and iota-carrageenan) were used for quantification and method precision and accuracy. Relative standard deviation (RSD) of repeatability for retention time, peak areas and inter-day precision was below 0.7%, 2.5% and 2.6%, respectively, which indicated good repeatability and precision. Recoveries (96.3-109.8%) also showed its fairly good accuracy. Regarding linearity, main polysaccharide standards from brown or red seaweeds showed a highly satisfactory correlation coefficient (r>0.999). Moreover, a good sensitivity was shown, with corresponding limits of detection and quantitation in mg/mL of 0.05-0.21 and 0.16-0.31, respectively. The method was applied to the MW estimation of standard algal polysaccharides, as well as to the soluble polysaccharide fractions from the brown seaweed Saccharina latissima and the red Mastocarpus stellatus, respectively. Although distribution of molecular weight was broad, the good repeatability for retention time provided a good precision in MW estimation of polysaccharides. Water- and alkali-soluble fractions from S. latissima ranged from very high (>2400 kDa) to low MW compounds (<6 kDa); this high heterogeneity could be attributable to the complex polysaccharide composition of brown algae. Regarding M. stellatus, sulfated galactans followed a descending order of MW (>1400 kDa to <10 kDa), related to the different solubility of carrageenans in red seaweeds. In summary, the method developed allows for the molecular weight analysis of seaweed polysaccharides with very good precision, accuracy, linearity and sensitivity within a short time. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Intra-session repeatability of lower limb muscles activation pattern during pedaling.

    PubMed

    Dorel, Sylvain; Couturier, Antoine; Hug, François

    2008-10-01

    Assessment of intra-session repeatability of muscle activation pattern is of considerable relevance for research settings, especially when used to determine changes over time. However, the repeatability of lower limb muscles activation pattern during pedaling is not fully established. Thus, we tested the intra-session repeatability of the activation pattern of 10 lower limb muscles during a sub-maximal cycling exercise. Eleven triathletes participated to this study. The experimental session consisted in a reference sub-maximal cycling exercise (i.e. 150 W) performed before and after a 53-min simulated training session (mean power output=200+/-12 W). Repeatability of EMG patterns was assessed in terms of muscle activity level (i.e. RMS of the mean pedaling cycle and burst) and muscle activation timing (i.e. onset and offset of the EMG burst) for the 10 following lower limb muscles: gluteus maximus (GMax), semimembranosus (SM), Biceps femoris (BF), vastus medialis (VM), rectus femoris (RF), vastus lateralis (VL), gastrocnemius medianus (GM) and lateralis (GL), soleus (SOL) and tibialis anterior (TA). No significant differences concerning the muscle activation level were found between test and retest for all the muscles investigated. Only VM, SOL and TA showed significant differences in muscle activation timing parameters. Whereas ICC and SEM values confirmed this weak repeatability, cross-correlation coefficients suggest a good repeatability of the activation timing parameters for all the studied muscles. Overall, the main finding of this work is the good repeatability of the EMG pattern during pedaling both in term of muscle activity level and muscle activation timing.

  15. Beverage Intake Assessment Questionnaire: Relative Validity and Repeatability in a Spanish Population with Metabolic Syndrome from the PREDIMED-PLUS Study.

    PubMed

    Ferreira-Pêgo, Cíntia; Nissensohn, Mariela; Kavouras, Stavros A; Babio, Nancy; Serra-Majem, Lluís; Martín Águila, Adys; Mauromoustakos, Andy; Álvarez Pérez, Jacqueline; Salas-Salvadó, Jordi

    2016-07-30

    We assess the repeatability and relative validity of a Spanish beverage intake questionnaire for assessing water intake from beverages. The present analysis was performed within the framework of the PREDIMED-PLUS trial. The study participants were adults (aged 55-75) with a BMI ≥27 and <40 kg/m², and at least three components of Metabolic Syndrome (MetS). A trained dietitian completed the questionnaire. Participants provided 24-h urine samples, and the volume and urine osmolality were recorded. The repeatability of the baseline measurement at 6 and 1 year was examined by paired Student's t-test comparisons. A total of 160 participants were included in the analysis. The Bland-Altman analysis showed relatively good agreement between total daily fluid intake assessed using the fluid-specific questionnaire, and urine osmolality and 24-h volume with parameter estimates of -0.65 and 0.22, respectively (R² = 0.20; p < 0.001). In the repeatability test, no significant differences were found between neither type of beverage nor total daily fluid intake at 6 months and 1-year assessment, compared to baseline. The proposed fluid-specific assessment questionnaire designed to assess the consumption of water and other beverages in Spanish adult individuals was found to be relatively valid with good repeatability.

  16. Polymeric Ionic Networks with High Charge Density: Solid-like Electrolytes in Lithium Metal Batteries

    DOE PAGES

    Zhang, Pengfei; Li, Mingtao; Jiang, Xueguang; ...

    2015-11-02

    Polymerized ionic networks (PINs) with six ion pairs per repeating unit are synthesized by nucleophilic-substitution-mediated polymerization or radical polymerization of monomers bearing six 1-vinylimidazolium cations. PIN-based solid-like electrolytes show good ionic conductivities (up to 5.32 × 10 -3 S cm -1 at 22 °C), wide electrochemical stability windows (up to 5.6 V), and good interfacial compatibility with the electrodes.

  17. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    PubMed

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  18. Comparing the field and laboratory emission cell (FLEC) with traditional emissions testing chambers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roache, N.F.; Guo, Z.; Fortmann, R.

    1996-12-31

    A series of tests was designed to evaluate the performance of the field and laboratory emission cell (FLEC) as applied to the testing of emissions from two indoor coating materials, floor wax and latex paint. These tests included validation of the repeatability of the test method, evaluation of the effect of different air velocities on source emissions, and a comparison of FLEC versus small chamber characterization of emissions. The FLEC exhibited good repeatability in characterization of emissions when applied to both sources under identical conditions. Tests with different air velocities showed significant effects on the emissions from latex paint, yetmore » little effect on emissions from the floor wax. Comparisons of data from the FLEC and small chamber show good correlation for measurements involving floor wax, but less favorable results for emissions from latex paint. The procedures and findings are discussed; conclusions are limited and include emphasis on the need for additional study and development of a standard method.« less

  19. Beverage Intake Assessment Questionnaire: Relative Validity and Repeatability in a Spanish Population with Metabolic Syndrome from the PREDIMED-PLUS Study

    PubMed Central

    Ferreira-Pêgo, Cíntia; Nissensohn, Mariela; Kavouras, Stavros A.; Babio, Nancy; Serra-Majem, Lluís; Martín Águila, Adys; Mauromoustakos, Andy; Álvarez Pérez, Jacqueline; Salas-Salvadó, Jordi

    2016-01-01

    We assess the repeatability and relative validity of a Spanish beverage intake questionnaire for assessing water intake from beverages. The present analysis was performed within the framework of the PREDIMED-PLUS trial. The study participants were adults (aged 55–75) with a BMI ≥27 and <40 kg/m2, and at least three components of Metabolic Syndrome (MetS). A trained dietitian completed the questionnaire. Participants provided 24-h urine samples, and the volume and urine osmolality were recorded. The repeatability of the baseline measurement at 6 and 1 year was examined by paired Student’s t-test comparisons. A total of 160 participants were included in the analysis. The Bland–Altman analysis showed relatively good agreement between total daily fluid intake assessed using the fluid-specific questionnaire, and urine osmolality and 24-h volume with parameter estimates of −0.65 and 0.22, respectively (R2 = 0.20; p < 0.001). In the repeatability test, no significant differences were found between neither type of beverage nor total daily fluid intake at 6 months and 1-year assessment, compared to baseline. The proposed fluid-specific assessment questionnaire designed to assess the consumption of water and other beverages in Spanish adult individuals was found to be relatively valid with good repeatability. PMID:27483318

  20. The repeatability of three diagnostic methods (visual using ICDAS II, laser fluorescence, and radiographic) for early caries detection

    NASA Astrophysics Data System (ADS)

    Sukmasari, S.; Lestari, W.; Ko, B. B.; Noh, Z.; Asmail, N.; Yaacob, N.

    2017-08-01

    Newly introduced ICDAS II as a visual method, laser fluorescence as another technique that have ability to quantify early mineral loss of tooth structure and intra oral radiograph, are methods can be used in the clinic. To provide standardization for comprehensive caries management at an early stage, all methods supposed to be tested between users. The objective of this research is to evaluate the repeatability of each system. It is a comparative cross sectional study using 100 extracted permanent teeth without obvious cavitation (premolar & molar) that were collected and stored in thymol solution. The teeth were embedded on the wax block and labeled with numbers. All 5 surfaces were examined by 5 examiners using visual (ICDAS II), laser fluorescence (LF) and radiographic examination. The data were then analyzed to measure intra and inter examiner repeatability using Cronbach’s alpha and inter-item correlation matrix. Intra-examiner repeatability for all examiners was >0.7. Chronbach’s a value for inter-examiner repeatability for ICDAS II was >0.8 on 3 surfaces except on buccal and lingual. LF exhibit repeatability of >0.8 on all surfaces. Radiograph shows a low value of inter examiner repeatability (<0.7). Lecturer examiners showed the highest agreement followed by undergraduate students for inter-item correlation while the 2nd and 3rd reading of LF displays the best agreement. ICDAS II score favors more non-invasive treatment compared to LF. ICDAS II showed good repeatability except on buccal and lingual surfaces. In line with some of the previous study, ICDAS II is applicable for caries detection in daily clinical basis. Laser fluorescence exhibits the highest repeatability while the radiograph showed weak inter-examiner repeatability. Treatment decisions of ICDAS II propose more preventive treatment for early caries lesions compared to laser fluorescence.

  1. The Role of Feedback and Differences between Good and Poor Decoders in a Repeated Word Reading Paradigm in First Grade

    ERIC Educational Resources Information Center

    van Gorp, Karly; Segers, Eliane; Verhoeven, Ludo

    2017-01-01

    The direct, retention, and transfer effects of repeated word and pseudoword reading were studied in a pretest, training, posttest, retention design. First graders (48 good readers, 47 poor readers) read 25 CVC words and 25 CVC pseudowords in ten repeated word reading sessions, preceded and followed by a transfer task with a different set of items.…

  2. Measurement system with high accuracy for laser beam quality.

    PubMed

    Ke, Yi; Zeng, Ciling; Xie, Peiyuan; Jiang, Qingshan; Liang, Ke; Yang, Zhenyu; Zhao, Ming

    2015-05-20

    Presently, most of the laser beam quality measurement system collimates the optical path manually with low efficiency and low repeatability. To solve these problems, this paper proposed a new collimated method to improve the reliability and accuracy of the measurement results. The system accuracy controlled the position of the mirror to change laser beam propagation direction, which can realize the beam perpendicularly incident to the photosurface of camera. The experiment results show that the proposed system has good repeatability and the measuring deviation of M2 factor is less than 0.6%.

  3. 151-km single-end phase-sensitive optical time-domain reflectometer assisted by optical repeater

    NASA Astrophysics Data System (ADS)

    Song, Muping; Zhu, Weiji; Xia, Qiaolan; Yin, Cong; Lu, Yan; Wu, Ying; Zhuang, Shouwang

    2018-02-01

    A phase-sensitive optical time-domain reflectometry (ϕOTDR) system that can detect intrusion over 150 km is presented. The ϕOTDR system uses nonbalanced optical repeaters to extend the sensing distance. The repeater consists of two erbium-doped optical fiber amplifiers (EDFAs) and one Raman amplifier (RA). One EDFA power amplifier amplifies the forward-transmitting pulse, and one EDFA preamplifier is used for the backscattering signal, respectively. The RA helps keeping the power along the fiber stable. The optical repeater is installed at the connection of two adjacent fibers to compensate the power decline due to fiber loss. It is easy to install the repeater midway among the fiber links in the system for longer-distance sensing since there is no need of modifying the original sensing system. The theoretical analysis of the repeater is given to describe its effect on the distributed sensing. In experiments, several ϕOTDR traces show a good agreement with theoretical results. Using the optical repeater, 35-Hz vibration at 151 km is successfully measured with signal-to-noise ratio of 8 dB without extra signal processing.

  4. ANALYSIS OF THE CITIES INTENSIVELY REPORTED BY TV NEWS DURING THE EMERGENCY PERIOD ON THE 2011 OFF THE PACIFIC COAST OF TOHOKU EARTHQUAKE DISASTER

    NASA Astrophysics Data System (ADS)

    Kokubun, Eriko; Numada, Muneyoshi; Meguro, Kimiro

    In the 2011 off the Pacific coast of Tohoku earthquake, we could observe concentration of news on damage and disaster response activity of specific municipalities and the high emphasis on the nuclear power plant accident and so on. The concentration of TV news caused the concentration of support such as releaf goods and donations to the specific area. This problem was repeated from the past disaster. The purpose of this research is to analyze the cities where was repeatedly reported by TV news during the emergency period on the 2011 off the pacific coast of tohoku earthquake disaster. This research defined the ratio of reported-city to show the comparison of the level of repeatedly reported cities. The results shows the big difference of reported times among the cities with same number of casualities.

  5. Optimization of Analytical Conditions for a Rapid Determination of Aniline in Environmental Water by Liquid Chromatography/Tandem Mass Spectrometry.

    PubMed

    Furukawa, Koji; Hashimoto, Makoto; Kaneco, Satoshi

    2017-01-01

    A rapid determination of aniline in environmental water was examined based on liquid chromatography/tandem mass spectrometry (LC/MS/MS). Environmental water samples were diluted 20-fold with Mill-Q water and measured by LC/MS/MS after adding a surrogate substance (aniline-d 5 ). In the results of the present study, the calibration curve of aniline showed good linearity in the range of 0.05 - 2.0 μg/L. Since the RSD (repeatability) by measuring repeatedly an aniline standard solution (0.05 μg/L, n = 7) was 3.2%, the repeatability of this work was very excellent. In addition, the recovery rate of aniline in environmental water was in the range of 99.0 - 102% with RSD 3.4 - 7.7%, and very good recovery test results were obtained. From these results, this analytical method was confirmed to be effective for aniline measurements of environmental water samples. Also, it is possible to conduct rapid analyses of aniline in environmental water without any solid-phase extraction process, compared to the solid-phase extraction-GC/MS method.

  6. [Stability of whole cell biocatalyst for biodiesel production from renewable oils].

    PubMed

    Sun, Ting; Du, Wei; Liu, Dehua; Li, Wei; Zeng, Jing; Dai, Lingmei

    2009-09-01

    Lipase-mediated biodiesel production becomes increasingly important because of mild reaction conditions, pollution free during the process and easy product separation. Compared with traditional immobilized lipase, whole cell biocatalyst is promising for biodiesel production because it is easy to prepare and has higher enzyme activity recovery. Rhizopus oryzae IFO4697 can be used as the catalyst for biodiesel production. To further study the stability of the whole cell biocatalyst is extremely important for its further application on large scale. This paper focuses on the stability study of Rhizopus oryzae IFO4697 when used for the methanolysis of renewable oils for biodiesel production. The results showed that water content was important for achieving high catalytic activity and good stability of the biocatalyst. The optimum water content was found to be 5%-15%. Both particle size and desiccation methods showed no obvious effect on the stability of the biocatalyst. With GA cross-linking pretreatment, the stability of the biocatalyst could be improved significantly. When Rhizopus oryzae IFO4697 repeatedly used for next batch reaction, direct vacuum filtration was found to be a good way for the maintenance of good stability of the biocatalyst. Under the optimum reaction conditions, the methyl ester yield could keep over 80% during 20 repeated reaction batches.

  7. Volunteering as Red Queen Mechanism for Cooperation in Public Goods Games

    NASA Astrophysics Data System (ADS)

    Hauert, Christoph; De Monte, Silvia; Hofbauer, Josef; Sigmund, Karl

    2002-05-01

    The evolution of cooperation among nonrelated individuals is one of the fundamental problems in biology and social sciences. Reciprocal altruism fails to provide a solution if interactions are not repeated often enough or groups are too large. Punishment and reward can be very effective but require that defectors can be traced and identified. Here we present a simple but effective mechanism operating under full anonymity. Optional participation can foil exploiters and overcome the social dilemma. In voluntary public goods interactions, cooperators and defectors will coexist. We show that this result holds under very diverse assumptions on population structure and adaptation mechanisms, leading usually not to an equilibrium but to an unending cycle of adjustments (a Red Queen type of evolution). Thus, voluntary participation offers an escape hatch out of some social traps. Cooperation can subsist in sizable groups even if interactions are not repeated, defectors remain anonymous, players have no memory, and assortment is purely random.

  8. Repeatability and Reversibility of the Humidity Sensor Based on Photonic Crystal Fiber Interferometer

    NASA Astrophysics Data System (ADS)

    Hindal, S. S.; Taher, H. J.

    2018-05-01

    The RH sensor operation based on water vapor adsorption and desorption at the silica-air interface within the PCF. Sensor fabrication is simple; it includes splicing and cleaving the PCF with SMF only. PCF (LMA-10) with a certain length spliced to SMF (Corning-28). The PCFI spectrum exhibits good sensitivity to the variations of humidity. The PCFI response is observed for range of relative humidity values from (27% RH to 85% RH), the interference peaks position is found to be shifted to longer wavelength as the humidity increases. In this work, a 6cm length of PCFs is used, and it shows a sensitivity of (2.41pm / %RH), good repeatability, and reversible in nature. This humidity sensor has distinguished features as that the sensor does not require the use of a hygroscopic material, robust, compact size, immunity to electromagnetic interference, and it has potential applications for high humidity environments.

  9. Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis.

    PubMed

    Fukuda, Shinichi; Beheregaray, Simone; Hoshi, Sujin; Yamanari, Masahiro; Lim, Yiheng; Hiraoka, Takahiro; Yasuno, Yoshiaki; Oshika, Tetsuro

    2013-12-01

    To evaluate the ability of parameters measured by three-dimensional (3D) corneal and anterior segment optical coherence tomography (CAS-OCT) and a rotating Scheimpflug camera combined with a Placido topography system (Scheimpflug camera with topography) to discriminate between normal eyes and forme fruste keratoconus. Forty-eight eyes of 48 patients with keratoconus, 25 eyes of 25 patients with forme fruste keratoconus and 128 eyes of 128 normal subjects were evaluated. Anterior and posterior keratometric parameters (steep K, flat K, average K), elevation, topographic parameters, regular and irregular astigmatism (spherical, asymmetry, regular and higher-order astigmatism) and five pachymetric parameters (minimum, minimum-median, inferior-superior, inferotemporal-superonasal, vertical thinnest location of the cornea) were measured using 3D CAS-OCT and a Scheimpflug camera with topography. The area under the receiver operating curve (AUROC) was calculated to assess the discrimination ability. Compatibility and repeatability of both devices were evaluated. Posterior surface elevation showed higher AUROC values in discrimination analysis of forme fruste keratoconus using both devices. Both instruments showed significant linear correlations (p<0.05, Pearson's correlation coefficient) and good repeatability (ICCs: 0.885-0.999) for normal and forme fruste keratoconus. Posterior elevation was the best discrimination parameter for forme fruste keratoconus. Both instruments presented good correlation and repeatability for this condition.

  10. Can Teaching Social Dilemmas Make People More Prosocial? An Experiment

    ERIC Educational Resources Information Center

    Martins, Julia; Fortmüller, Richard; Powell, Owen

    2017-01-01

    Economics and business students regularly behave less prosocially than others. Can ethics training reverse this tendency? Results from a repeated public goods experiment reveal that it can. Students who attend an interactive lecture on social dilemmas show significantly more cooperation than others. However, the lecture does not appear to increase…

  11. Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes.

    PubMed

    Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske

    2014-01-01

    To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC ≧ 0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC ≧ 0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = -0.384 and -0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29 ± 0.21 vs. 6.96 ± 0.17 ms, p<0.05) and lower deformation amplitude (1.06 ± 0.07 vs. 1.17 ± 0.08 mm, p < 0.05). CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter.

  12. Imprints of superfluidity on magnetoelastic quasiperiodic oscillations of soft gamma-ray repeaters.

    PubMed

    Gabler, Michael; Cerdá-Durán, Pablo; Stergioulas, Nikolaos; Font, José A; Müller, Ewald

    2013-11-22

    Our numerical simulations show that axisymmetric, torsional, magnetoelastic oscillations of magnetars with a superfluid core can explain the whole range of observed quasiperiodic oscillations (QPOs) in the giant flares of soft gamma-ray repeaters. There exist constant phase QPOs at f is < or approximately equal to 150 Hz and resonantly excited high-frequency QPOs (f>500 Hz), in good agreement with observations. The range of magnetic field strengths required to match the observed QPO frequencies agrees with that from spin-down estimates. These results suggest that there is at least one superfluid species in magnetar cores.

  13. Successful treatment of growing basilar artery dissecting aneurysm by pipeline flow diversion embolization device.

    PubMed

    Gong, Dasen; Yan, Bernard; Dowling, Richard; Mitchell, Peter

    2014-07-01

    We describe a case of successful management of a growing basilar artery dissecting aneurysm by the Pipeline flow diversion embolization device (PED). A 48-year-old woman presented with severe headache, neck pain, and altered consciousness. Computed tomography showed subarachnoid hemorrhage located in basal cisterns, with a pontine infarct shown on magnetic resonance imaging. Digital subtraction angiography showed dissecting aneurysm of the trunk of the basilar artery, with growth over time on repeated imaging. Repeated imaging demonstrated growth in size of the aneurysm. The aneurysm was treated with PED with complete obliteration of the basilar artery aneurysm. Subsequent follow-up demonstrated good clinical recovery. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  14. Evaluation of wheelchair resistive forces during straight and turning trajectories across different wheelchair configurations using free-wheeling coast-down test.

    PubMed

    Lin, Jui-Te; Huang, Morris; Sprigle, Stephen

    2015-01-01

    The purpose of this study was to develop a simple approach to evaluate resistive frictional forces acting on manual wheelchairs (MWCs) during straight and turning maneuvers. Using a dummy-occupied MWC, decelerations were measured via axle-mounted encoders during a coast-down protocol that included straight trajectories and fixed-wheel turns. Eight coast-down trials were conducted to test repeatability and repeated on separate days to evaluate reliability. Without changing the inertia of the MWC system, three tire inflations were chosen to evaluate the sensitivity in discerning deceleration differences using effect sizes. The technique was also deployed to investigate the effect of different MWC masses and weight distributions on resistive forces. Results showed that the proposed coast-down technique had good repeatability and reliability in measuring decelerations and had good sensitivity in discerning differences in tire inflation, especially during turning. The results also indicated that increased loading on drive wheels reduced resistive losses in straight trajectories while increasing resistive losses during turning. During turning trajectories, the presence of tire scrub contributes significantly to the amount of resistive force. Overall, this new coast-down technique demonstrates satisfactory repeatability and sensitivity for detecting deceleration changes during straight and turning trajectories, indicating that it can be used to evaluate resistive loss of different MWC configurations and maneuvers.

  15. Comparison of Eyemetrics and Orbscan automated method to determine horizontal corneal diameter

    PubMed Central

    Venkataraman, Arvind; Mardi, Sapna K; Pillai, Sarita

    2010-01-01

    Purpose: To compare horizontal corneal diameter measurements using the Orbscan Eyemetrics function and Orbscan corneal topographer. Materials and Methods: Seventy-three eyes of 37 patients were included in the study. In all cases, the automated white-to-white (WTW) measurements were obtained using Orbscan by two observers. Using the Eyemetrics function, the WTW was measured manually by the same observers from limbus to limbus using the digital caliper passing through the five point corneal reflections on the Orbscan real image. The data was analyzed using SPSS software for correlation, reliability and inter-rater repeatability. Results: The mean horizontal corneal diameter was 11.74 ± 0.32mm (SD) with the Orbscan and 11.92 ± 0.33mm (SD) with Eyemetrics Software-based measurement. A good positive correlation (Spearman r = 0.720, P = 0.026) was found between these two measurements. The coefficient of inter-rater repeatability was 0.89 for the Orbscan and 0.94 for the Eyemetrics software measurements on the anterior segment images. The Bland and Altman analysis showed large limits of agreement between Orbscan WTW and Eyemetrics WTW measurements. The intra-session repeatability scores for repeat measurements for the Orbscan WTW and Eyemetrics measurements were good. Conclusion: Eyemetrics can be used to measure WTW and the Eyemetrics measured WTW was longer than the WTW measured by Orbscan. PMID:20413925

  16. A Dual-Range Strain Gage Weighing Transducer Employing Automatic Switching

    Treesearch

    Rodger A. Arola

    1968-01-01

    Describes a dual-range strain gage transducer which has proven to be an excellent weight-sensing device for weighing trees and tree-length logs; discusses basic principals of the design and operation; and shows that a single transducer having two sensitivity ranges with automatic internal switching can sense weight with good repeatability and that one calibration curve...

  17. The repeatability and characteristics of right ventricular longitudinal strain imaging by speckle-tracking echocardiography in healthy dogs.

    PubMed

    Morita, T; Nakamura, K; Osuga, T; Yokoyama, N; Khoirun, N; Morishita, K; Sasaki, N; Ohta, H; Takiguchi, M

    2017-08-01

    To assess the repeatability and characteristics of echocardiographic indices of the right ventricular (RV) function derived from speckle-tracking echocardiography. Fourteen laboratory Beagles and 103 privately owned dogs without cardiac disease were involved in this study. Right ventricular longitudinal strain, strain rate, and a strain-related index for assessing RV dyssynchrony derived from speckle-tracking echocardiography were obtained by two different observers using five Beagles. Within-day, between-day, and interobserver coefficients of variation and the intraclass correlation coefficient of speckle-tracking echocardiography indices were determined. Both speckle-tracking echocardiography and conventional indices of RV function, including the peak velocity of systolic tricuspid annular motion, tricuspid annulus plane systolic excursion, fractional area change, and the Tei index, were obtained from 14 Beagles and 103 privately owned dogs. Relationships between echocardiographic indices and the body weight, heart rate, age, and sex were estimated by regression analysis. Speckle-tracking echocardiographic indices showed good within-day repeatability, between-day and interobserver repeatability were moderate to good. In large dogs, RV longitudinal strain, strain rate, and fractional area change were significantly decreased, while the index of RV dyssynchrony, systolic tricuspid annular motion, tricuspid annulus plane systolic excursion, and the Tei index were increased. All speckle-tracking and conventional echocardiographic indices were correlated with the body weight. The speckle-tracking echocardiography indices were highly repeatable and body weight affected speckle-tracking echocardiography indices in dogs. Further studies are needed to apply speckle-tracking echocardiography indices in dogs with cardiac disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: quantification and reproducibility.

    PubMed

    Cutajar, Marica; Thomas, David L; Hales, Patrick W; Banks, T; Clark, Christopher A; Gordon, Isky

    2014-06-01

    To investigate the reproducibility of arterial spin labelling (ASL) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and quantitatively compare these techniques for the measurement of renal blood flow (RBF). Sixteen healthy volunteers were examined on two different occasions. ASL was performed using a multi-TI FAIR labelling scheme with a segmented 3D-GRASE imaging module. DCE MRI was performed using a 3D-FLASH pulse sequence. A Bland-Altman analysis was used to assess repeatability of each technique, and determine the degree of correspondence between the two methods. The overall mean cortical renal blood flow (RBF) of the ASL group was 263 ± 41 ml min(-1) [100 ml tissue](-1), and using DCE MRI was 287 ± 70 ml min(-1) [100 ml tissue](-1). The group coefficient of variation (CVg) was 18 % for ASL and 28 % for DCE-MRI. Repeatability studies showed that ASL was more reproducible than DCE with CVgs of 16 % and 25 % for ASL and DCE respectively. Bland-Altman analysis comparing the two techniques showed a good agreement. The repeated measures analysis shows that the ASL technique has better reproducibility than DCE-MRI. Difference analysis shows no significant difference between the RBF values of the two techniques. Reliable non-invasive monitoring of renal blood flow is currently clinically unavailable. Renal arterial spin labelling MRI is robust and repeatable. Renal dynamic contrast-enhanced MRI is robust and repeatable. ASL blood flow values are similar to those obtained using DCE-MRI.

  19. Nudge for (the Public) Good: How Defaults Can Affect Cooperation

    PubMed Central

    Fosgaard, Toke R.; Piovesan, Marco

    2015-01-01

    In this paper we test the effect of non-binding defaults on the level of contribution to a public good. We manipulate the default numbers appearing on the decision screen to nudge subjects toward a free-rider strategy or a perfect conditional cooperator strategy. Our results show that the vast majority of our subjects did not adopt the default numbers, but their stated strategy was affected by the default. Moreover, we find that our manipulation spilled over to a subsequent repeated public goods game where default was not manipulated. Here we found that subjects who previously saw the free rider default were significantly less cooperative than those who saw the perfect conditional cooperator default. PMID:26717569

  20. Nudge for (the Public) Good: How Defaults Can Affect Cooperation.

    PubMed

    Fosgaard, Toke R; Piovesan, Marco

    2015-01-01

    In this paper we test the effect of non-binding defaults on the level of contribution to a public good. We manipulate the default numbers appearing on the decision screen to nudge subjects toward a free-rider strategy or a perfect conditional cooperator strategy. Our results show that the vast majority of our subjects did not adopt the default numbers, but their stated strategy was affected by the default. Moreover, we find that our manipulation spilled over to a subsequent repeated public goods game where default was not manipulated. Here we found that subjects who previously saw the free rider default were significantly less cooperative than those who saw the perfect conditional cooperator default.

  1. Digital Photoplethysmography for Assessment of Arterial Stiffness: Repeatability and Comparison with Applanation Tonometry

    PubMed Central

    Östling, Gerd; Nilsson, Peter M.

    2015-01-01

    Introduction Arterial stiffness is an independent risk factor for cardiovascular morbidity and can be assessed by applanation tonometry by measuring pulse wave velocity (PWV) and augmentation index (AIX) by pressure pulse wave analysis (PWA). As an inexpensive and operator independent alternative, photoelectric plethysmography (PPG) has been introduced with analysis of the digital volume pulse wave (DPA) and its second derivatives of wave reflections. Objective The objective was to investigate the repeatability of arterial stiffness parameters measured by digital pulse wave analysis (DPA) and the associations to applanation tonometry parameters. Methods and Results 112 pregnant and non-pregnant individuals of different ages and genders were examined with SphygmoCor arterial wall tonometry and Meridian DPA finger photoplethysmography. Coefficients of repeatability, Bland-Altman plots, intraclass correlation coefficients and correlations to heart rate (HR) and body height were calculated for DPA variables, and the DPA variables were compared to tonometry variables left ventricular ejection time (LVET), PWV and AIX. No DPA variable showed any systematic measurement error or excellent repeatability, but dicrotic index (DI), dicrotic dilatation index (DDI), cardiac ejection elasticity index (EEI), aging index (AI) and second derivatives of the crude pulse wave curve, b/a and e/a, showed good repeatability. Overall, the correlations to AIX were better than to PWV, with correlations coefficients >0.70 for EEI, AI and b/a. Considering the level of repeatability and the correlations to tonometry, the overall best DPA parameters were EEI, AI and b/a. The two pansystolic time parameters, ejection time compensated (ETc) by DPA and LVET by tonometry, showed a significant but weak correlation. Conclusion For estimation of the LV function, ETc, EEI and b/a are suitable, for large artery stiffness EEI, and for small arteries DI and DDI. The only global parameter, AI, showed a high repeatability and the overall best correlations with AIX and PWV. PMID:26291079

  2. Optimisation of a sample preparation procedure for the screening of fungal infection and assessment of deoxynivalenol content in maize using mid-infrared attenuated total reflection spectroscopy.

    PubMed

    Kos, Gregor; Lohninger, Hans; Mizaikoff, Boris; Krska, Rudolf

    2007-07-01

    A sample preparation procedure for the determination of deoxynivalenol (DON) using attenuated total reflection mid-infrared spectroscopy is presented. Repeatable spectra were obtained from samples featuring a narrow particle size distribution. Samples were ground with a centrifugal mill and analysed with an analytical sieve shaker. Particle sizes of <100, 100-250, 250-500, 500-710 and 710-1000 microm were obtained. Repeatability, classification and quantification abilities for DON were compared with non-sieved samples. The 100-250 microm fraction showed the best repeatability. The relative standard deviation of spectral measurements improved from 20 to 4.4% and 100% of sieved samples were correctly classified compared with 79% of non-sieved samples. The DON level in analysed fractions was a good estimate of overall toxin content.

  3. Repeatability and reproducibility of ocular biometry using a new noncontact optical low-coherence interferometer.

    PubMed

    Huang, Jinhai; Savini, Giacomo; Wu, Fan; Yu, Xinxin; Yang, Jing; Yu, Ayong; Yu, Ye; Wang, Qinmei

    2015-10-01

    To assess the precision of ocular biometry with a new noncontact optical low-coherence interferometer (Aladdin) in healthy subjects and patients with cataracts. Eye Hospital of Wenzhou Medical University, Wenzhou, China. Observational cross-sectional study. Eyes from healthy subjects and eyes from patients with cataracts were examined with the new interferometer. Axial length (AL), anterior chamber depth (ACD), keratometry (K), and white-to-white (WTW) values were measured by 2 operators. The test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were calculated to evaluate intraoperator repeatability. Different-operator comparison was analyzed with paired t tests and Bland-Altman plots to assess interoperator reproducibility. Ninety-eight people were enrolled for this study, of which 52 eyes were from healthy subjects and 46 eyes were from patients with cataracts. The AL was the most repeatable and reproducible parameter. The ACD, K values, and WTW measurements were highly repeatable in healthy subjects with CoV less than 0.89% and ICC more than 0.94. However, in patients with cataracts, high repeatability could only be observed for AL, ACD, and K values, whereas WTW measurement had test-retest repeatability of 0.80 mm and an ICC of 0.795. Bland-Altman analysis also showed good agreement between the 2 operators for ocular component measurements, except that the WTW in patients with cataracts had wider 95% limits of agreement (range -0.88 to 0.95 mm). The new biometer showed excellent intraoperator repeatability and interoperator reproducibility for AL, ACD, and K values measurements in both groups. The precision of WTW measurements was lower in patients with cataracts. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. CRISPR Detection From Short Reads Using Partial Overlap Graphs.

    PubMed

    Ben-Bassat, Ilan; Chor, Benny

    2016-06-01

    Clustered regularly interspaced short palindromic repeats (CRISPR) are structured regions in bacterial and archaeal genomes, which are part of an adaptive immune system against phages. CRISPRs are important for many microbial studies and are playing an essential role in current gene editing techniques. As such, they attract substantial research interest. The exponential growth in the amount of bacterial sequence data in recent years enables the exploration of CRISPR loci in more and more species. Most of the automated tools that detect CRISPR loci rely on fully assembled genomes. However, many assemblers do not handle repetitive regions successfully. The first tool to work directly on raw sequence data is Crass, which requires reads that are long enough to contain two copies of the same repeat. We present a method to identify CRISPR repeats from raw sequence data of short reads. The algorithm is based on an observation differentiating CRISPR repeats from other types of repeats, and it involves a series of partial constructions of the overlap graph. This enables us to avoid many of the difficulties that assemblers face, as we merely aim to identify the repeats that belong to CRISPR loci. A preliminary implementation of the algorithm shows good results and detects CRISPR repeats in cases where other existing tools fail to do so.

  5. Fate of iprovalicarb, indoxacarb, and boscalid residues in grapes and wine by GC-ITMS analysis.

    PubMed

    Angioni, Alberto; Dedola, Fabrizio; Garau, Vincenzo Luigi; Schirra, Mario; Caboni, Pierluigi

    2011-06-22

    The behavior in field and the transfer from grapes to wine during winemaking of iprovalicarb, indoxacarb, and boscalid was studied. The residue levels found in grapes were far below the MRLs set for grapes in EU, accounting at harvest time 0.81, 0.43, and 4.23 mg/kg for iprovalicarb, indoxacarb, and boscalid, respectively. The residue levels in the samples treated with boscalid may have residual problems (due to an accumulation effect) if repeated field treatments will be performed. Winemaking experiments showed a complete transfer of all pesticide from grapes to the must, while in wine the residues were low or negligible due to the adsorbing effect of lees and pomace. The clarification experiments showed a good removal of pesticide residues from the wine media, for all pesticides. The GC-ITMS method showed good performance with adequate recoveries ranging from 75 to 115%, and good method limits of quantitation (LOQs) and of determination (LODs) far below MRLs.

  6. Variable Solutions to the Same Problem: Aberrant Practice Effects in Object Naming by Three Aphasic Patients

    ERIC Educational Resources Information Center

    Wingfield, Arthur; Brownell, Hiram; Hoyte, Ken J.

    2006-01-01

    Although deficits in confrontation naming are a common consequence of damage to the language areas of the left cerebral hemisphere, some patients with aphasia show relatively good naming ability. We measured effects of repeated practice on naming latencies for a set of pictured objects by three aphasic patients with near-normal naming ability and…

  7. Cross-cultural adaptation of an Arabic version of the 10-item hearing handicap inventory.

    PubMed

    Weinstein, Barbara E; Rasheedy, Doha; Taha, Hend M; Fatouh, Fathy N

    2015-05-01

    The purpose of this study was to translate and culturally adapt an Arabic version of the hearing handicap inventory for the elderly - screening (HHIE-S). The HHIE-S was translated following cross-cultural adaptation guidelines, and pretested in 20 elderly patients with hearing impairment. Next, the adapted Arabic HHIE-S underwent psychometric evaluation. The results were confirmed by pure-tone audiometer (PTA) examination. The patients completed the HHIE-S again after one hour. The validation of the questionnaire using Cronbach's alpha (internal consistency), (construct validity), and intraclass correlation coefficients (repeatability) was performed. Twenty elderly subjects with hearing impairment were recruited for the pretesting stage, and 100 elderly subjects were recruited for the psychometric evaluation stage. Patients with acute illness, functional dependency, cognitive impairment, and previous users of hearing aids were excluded. The adapted Arabic HHIE-S showed good internal consistency (α = 0.902). Construct validity was good, as high correlations were found between the scale and the PTA outcome (r = 0.688, p = 0.000). Repeatability was high (ICC = 0.986). This study showed that the adapted Arabic HHIE-S is a valid and reliable questionnaire for the assessment of handicapping hearing impairment in Egyptian elderly patients.

  8. [Study on HPLC fingerprint of flavonoids from Houttuynia cordata by comparing with fingerprint reference].

    PubMed

    Zhang, Ting-Ting; Wu, Yi; Hang, Tai-Jun

    2009-05-01

    To establish a stable and repeatable HPLC fingerprint standard and evaluate the flavonoids from Houttuynia cordata qualitatively and quantitatively. HPLC separation was performed on a C18 column with methanol-0.1% phosphoric acid mixed solution as mobile phase in gradient elution mode. The fingerprint reference was determined as one of the most typical chromatograms and used to be compared with other samples through Cosine and Relative Euclid Distance methods, thus the chromatographic fingerprints of flavonoids from Houttuynia cordata were evaluated by constitutes and contents, respectively. Fourteen mutual peaks were fixed in the HPLC fingerprint of flavonoids from Houttaynia cordata. It showed good results in validation tests in which the quercitrin's peak was set as the reference peak to calculate relative retention time and area of other peaks in the chromatograms, and the RSD were less than 0.2% and 5.0%, respectively. The linear ranges for quercitrin was 1.07-83.4 microg/mL (r=0.9999) and the average recovery was 100.3%. The method shows good repeatability, ruggedness and reliability. Comparing with the established reference fingerprint, the evaluation system including Cosine and Relative Euclid Distance methods lays dependable foundation for controlling the quality of Houttuynia cordata.

  9. [Clinical outcomes and economic analysis of two ovulation induction protocols in patients undergoing repeated IVF/ICSI cycles].

    PubMed

    Chen, Xiao; Geng, Ling; Li, Hong

    2014-04-01

    To compare the clinical outcomes and cost-effectiveness of luteal phase down-regulation with gonadotrophin-releasing hormone (GnRH) agonist protocol and GnRH antagonist protocol in patients undergoing repeated in vitro fertilization and intracytoplasmic sperm injection (IVF-ICSI) cycles. A retrospective analysis of clinical outcomes and costs was conducted among 198 patients undergoing repeated IVF-ICSI cycles, including 109 receiving luteal phase down-regulation with GnRH agonist protocol (group A) and 89 receiving GnRH antagonist protocol (group B). The numbers of oocytes retrieved and good embryos, clinical pregnancy rate, abortion rate, the live birth rate, mean total cost, and the cost-effective ratio were compared between the two groups. In patients undergoing repeated IVF-ICSI cycles, the two protocols produced no significant differences in the number of good embryos, clinical pregnancy rate, abortion rate, or twin pregnancy rate. Compared with group B, group A had better clinical outcomes though this difference was not statistically significant. The number of retrieved oocytes was significantly greater and live birth rate significantly higher in group A than in group B (9.13=4.98 vs 7.11=4.74, and 20.2% vs 9.0%, respectively). Compared with group B, group A had higher mean total cost per cycle but lower costs for each oocyte retrieved (2729.11 vs 3038.60 RMB yuan), each good embryo (8867.19 vs 9644.85 RMB yuan), each clinical pregnancy (77598.06 vs 96139.85 RMB yuan). For patients undergoing repeated IVF/ICSI cycle, luteal phase down-regulation with GnRH agonist protocol produces good clinical outcomes with also good cost-effectiveness in spite an unsatisfactory ovarian reserve.

  10. Repeated Prescribed Burning in Aspen

    Treesearch

    Donald A. Perala

    1974-01-01

    Infrequent burning weather, low flammability of the aspen-hardwood association, and prolific sprouting and seeding of shrubs and hardwoods made repeated dormant season burning a poor tool to convert good site aspen to conifers. Repeat fall burns for wildlife habitat maintenance is workable if species composition changes are not important.

  11. pH-responsive hydrogel coated fiber Bragg grating-based chemo mechanical sensor bioreactor applications

    NASA Astrophysics Data System (ADS)

    Kishore, P. V. N.; Sai Shankar, M.

    2017-04-01

    This paper describes a fiber optics based pH sensor by using wavelength modulated techniques. Fiber Bragg grating (FBG) is functionalized with a stimulus responsive hydrogel which induces a strain on FBG due to mechanical expansion of the gel in response to ambient pH changes. The gel is synthesized from the blends of Poly (vinyl alcohol)/Poly (acrylic acid). The induced strain results in a shift of FBG reflected peak which is monitored by an interrogator. The sensor system shows a good linearity in acidic pH range of 3 to 7 with a sensitivity of 12.16pm/pH. Besides that it shows good repeatability which proves it to be fit for pH sensing applications.

  12. Hydrogel-coated fiber Bragg grating sensor for pH monitoring

    NASA Astrophysics Data System (ADS)

    Pabbisetti, Vayu Nandana Kishore; Madhuvarasu, Sai Shankar

    2016-06-01

    We present a fiber-optic wavelength-modulated sensor for pH applications. Fiber Bragg grating (FBG) is functionalized with a stimulus-responsive hydrogel that induces a strain on FBG due to mechanical expansion of the gel in response to ambient pH changes. The gel is synthesized from the blends of poly (vinyl alcohol)/poly (acrylic acid). The induced strain results in a shift of FBG reflected peak that is monitored by an interrogator. The sensor system shows good linearity in the acidic pH range of 3 to 7 with a sensitivity of 12.16 pm/pH. In addition, it shows good repeatability and oscillator behavior, which proves it to be fit for pH sensing applications.

  13. Dual-Phase Lock-In Amplifier Based on FPGA for Low-Frequencies Experiments

    PubMed Central

    Macias-Bobadilla, Gonzalo; Rodríguez-Reséndiz, Juvenal; Mota-Valtierra, Georgina; Soto-Zarazúa, Genaro; Méndez-Loyola, Maurino; Garduño-Aparicio, Mariano

    2016-01-01

    Photothermal techniques allow the detection of characteristics of material without invading it. Researchers have developed hardware for some specific Phase and Amplitude detection (Lock-In Function) applications, eliminating space and unnecessary electronic functions, among others. This work shows the development of a Digital Lock-In Amplifier based on a Field Programmable Gate Array (FPGA) for low-frequency applications. This system allows selecting and generating the appropriated frequency depending on the kind of experiment or material studied. The results show good frequency stability in the order of 1.0 × 10−9 Hz, which is considered good linearity and repeatability response for the most common Laboratory Amplitude and Phase Shift detection devices, with a low error and standard deviation. PMID:26999138

  14. Dual-Phase Lock-In Amplifier Based on FPGA for Low-Frequencies Experiments.

    PubMed

    Macias-Bobadilla, Gonzalo; Rodríguez-Reséndiz, Juvenal; Mota-Valtierra, Georgina; Soto-Zarazúa, Genaro; Méndez-Loyola, Maurino; Garduño-Aparicio, Mariano

    2016-03-16

    Photothermal techniques allow the detection of characteristics of material without invading it. Researchers have developed hardware for some specific Phase and Amplitude detection (Lock-In Function) applications, eliminating space and unnecessary electronic functions, among others. This work shows the development of a Digital Lock-In Amplifier based on a Field Programmable Gate Array (FPGA) for low-frequency applications. This system allows selecting and generating the appropriated frequency depending on the kind of experiment or material studied. The results show good frequency stability in the order of 1.0 × 10(-9) Hz, which is considered good linearity and repeatability response for the most common Laboratory Amplitude and Phase Shift detection devices, with a low error and standard deviation.

  15. When being narrow minded is a good thing: locally biased people show stronger contextual cueing.

    PubMed

    Bellaera, Lauren; von Mühlenen, Adrian; Watson, Derrick G

    2014-01-01

    Repeated contexts allow us to find relevant information more easily. Learning such contexts has been proposed to depend upon either global processing of the repeated contexts, or alternatively processing of the local region surrounding the target information. In this study, we measured the extent to which observers were by default biased to process towards a more global or local level. The findings showed that the ability to use context to help guide their search was strongly related to an observer's local/global processing bias. Locally biased people could use context to help improve their search better than globally biased people. The results suggest that the extent to which context can be used depends crucially on the observer's attentional bias and thus also to factors and influences that can change this bias.

  16. Reliability of Corneal Dynamic Scheimpflug Analyser Measurements in Virgin and Post-PRK Eyes

    PubMed Central

    Chen, Xiangjun; Stojanovic, Aleksandar; Hua, Yanjun; Eidet, Jon Roger; Hu, Di; Wang, Jingting; Utheim, Tor Paaske

    2014-01-01

    Purpose To determine the measurement reliability of CorVis ST, a dynamic Scheimpflug analyser, in virgin and post-photorefractive keratectomy (PRK) eyes and compare the results between these two groups. Methods Forty virgin eyes and 42 post-PRK eyes underwent CorVis ST measurements performed by two technicians. Repeatability was evaluated by comparing three consecutive measurements by technician A. Reproducibility was determined by comparing the first measurement by technician A with one performed by technician B. Intraobserver and interobserver intraclass correlation coefficients (ICCs) were calculated. Univariate analysis of covariance (ANCOVA) was used to compare measured parameters between virgin and post-PRK eyes. Results The intraocular pressure (IOP), central corneal thickness (CCT) and 1st applanation time demonstrated good intraobserver repeatability and interobserver reproducibility (ICC≧0.90) in virgin and post-PRK eyes. The deformation amplitude showed a good or close to good repeatability and reproducibility in both groups (ICC≧0.88). The CCT correlated positively with 1st applanation time (r = 0.437 and 0.483, respectively, p<0.05) and negatively with deformation amplitude (r = −0.384 and −0.375, respectively, p<0.05) in both groups. Compared to post-PRK eyes, virgin eyes showed longer 1st applanation time (7.29±0.21 vs. 6.96±0.17 ms, p<0.05) and lower deformation amplitude (1.06±0.07 vs. 1.17±0.08 mm, p<0.05). Conclusions CorVis ST demonstrated reliable measurements for CCT, IOP, and 1st applanation time, as well as relatively reliable measurement for deformation amplitude in both virgin and post-PRK eyes. There were differences in 1st applanation time and deformation amplitude between virgin and post-PRK eyes, which may reflect corneal biomechanical changes occurring after the surgery in the latter. PMID:25302580

  17. Translation to Spanish and Validation of the Specific Saint George's Questionnaire for Idiopathic Pulmonary Fibrosis.

    PubMed

    Capparelli, Ignacio; Fernandez, Martín; Saadia Otero, Marcela; Steimberg, Jimena; Brassesco, María; Campobasso, Ana; Palacios, Sandra; Caro, Fabian; Alberti, María Laura; Rabinovich, Roberto A; Paulin, Francisco

    2018-02-01

    Interstitial lung disease (ILD) is associated with low exercise tolerance, dyspnea, and decreased health-related quality of life (HRQL). Idiopathic pulmonary fibrosis (IPF) is one of the most prevalent in the group. A specific version of the Saint George's questionnaire (SGRQ-I) has been developed to quantify the HRQL of IPF patients. However, this tool is not currently validated in the Spanish language. The objective was to translate into Spanish and validate the specific Saint George's Respiratory Questionnaire for idiopathic pulmonary fibrosis (SGRQ-I). The repeatability, internal consistency and construct validity of the SGRQ-I in Spanish were analyzed after a backtranslation process. In total, 23 outpatients with IPF completed the translated SGRQ-I twice, 7 days apart. Repeatability was studied, revealing good concordance in test-retest with an ICC (interclass correlation coefficient) of 0.96 (P<.001). Internal consistency was good for different questionnaire items (Cronbach's alpha of 0.9 including and 0.81 excluding the total value) (P<.001). The total score of the questionnaire showed good correlation with forced vital capacity FVC% (r=-0.44; P=.033), diffusing capacity of the lungs for carbon monoxide (DL CO %) (r=-0.55; P=.011), partial pressure of oxygen in arterial blood PaO 2 (r=-0.44; P=.036), Medical Research Council Dyspnea scale (r=-0.65; P<.001), and number of steps taken in 24hours (r=-0.47; P=.024). The Spanish version of SGRQ-Ideveloped by our group shows good internal consistency, reproducibility and validity, so it can be used for the evaluation of quality of life (QOL) in IPF patients. Copyright © 2017 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Repeatability of short-duration transient visual evoked potentials in normal subjects.

    PubMed

    Tello, Celso; De Moraes, Carlos Gustavo V; Prata, Tiago S; Derr, Peter; Patel, Jayson; Siegfried, John; Liebmann, Jeffrey M; Ritch, Robert

    2010-06-01

    To evaluate the within-session and inter-session repeatability of a new, short-duration transient visual evoked potential (SD-tVEP) device on normal individuals, we tested 30 normal subjects (20/20 visual acuity, normal 24-2 SITA Standard VF) with SD-tVEP. Ten of these subjects had their tests repeated within 1-2 months from the initial visit. Synchronized single-channel EEG was recorded using a modified Diopsys Enfant System (Diopsys, Inc., Pine Brook, New Jersey, USA). A checkerboard stimulus was modulated at two reversals per second. Two different contrasts of checkerboard reversal patterns were used: 85% Michelson contrast with a mean luminance of 66.25 cd/m(2) and 10% Michelson contrast with a mean luminance of 112 cd/m(2). Each test lasted 20 s. Both eyes, independently and together, were tested 10 times (5 times at each contrast level). The following information was identified from the filtered N75-P100-N135 complex: N75 amplitude, N75 latency, P100 amplitude, P100 latency, and Delta Amplitude (N75-P100). The median values for each eye's five SD-tVEP parameters were calculated and grouped into two data sets based on contrast level. Mean age was 27.3 +/- 5.2 years. For OD only, the median (95% confidence intervals) of Delta Amplitude (N75-P100) amplitudes at 10% and 85% contrast were 4.6 uV (4.1-5.9) and 7.1 uV (5.15-9.31). The median P100 latencies were 115.2 ms (112.0-117.7) and 104.0 ms (99.9-106.0). There was little within-session variability for any of these parameters. Intraclass correlation coefficients ranged between 0.64 and 0.98, and within subject coefficients of variation were 3-5% (P100 latency) and 15-30% (Delta Amplitude (N75-P100) amplitude). Bland-Altman plots showed good agreement between the first and fifth test sessions (85% contrast Delta Amplitude (N75-P100) delta amplitude, mean difference, 0.48 mV, 95% CI, -0.18-1.12; 85% contrast P100 latency delay, -0.82 ms, 95% CI, -3.12-1.46; 10% contrast Delta Amplitude (N75-P100) amplitude, 0.58 mV, 95% CI, -0.27-1.45; 10% contrast P100 latency delay, -2.05 mV, 95% CI, -5.12-1.01). The inter-eye correlation and agreement were significant for both SD-tVEP amplitude and P100 latency measurements. For the subset of eyes in which the inter-session repeatability was tested, the intraclass correlation coefficients ranged between 0.71 and 0.86 with good agreement shown on Bland-Altman plots. Short-duration transient VEP technology showed good within-session, inter-session repeatability, and good inter-eye correlation and agreement.

  19. Evaluation of the Implementation of Good Handling Practices in Food and Beverage Areas of Hotels.

    PubMed

    Serafim, A L; Hecktheuer, L H R; Stangarlin-Fiori, L; Medeiros, L B; Martello, L; Machado, C E

    2015-11-01

    Because of the major international-level events that have recently been held in Brazil, concerns about the sensory and hygienic-sanitary conditions of food have increased. The objective of this study was to evaluate the implementation of good handling practices in food and beverage areas of hotels, with and without outsourced professional intervention. We evaluated 19 food and beverage areas in hotels in Porto Alegre, Rio do Sul, Brazil, using a checklist that was developed by a municipal surveillance team based on existing laws for good handling practices. The evaluation was done by a skilled professional in the food safety area on two occasions, at the beginning of the study (January to May 2013) and at the end (July to November 2014), and the establishments were classified as good, regular, or poor. After the baseline evaluation, an action plan listing the noncompliance found at each location was given to those responsible for the establishments, and a period of 1 year 6 months was stipulated for improvements to be made. In the repeat evaluation, those responsible for the establishments were asked whether they had hired an outsourced professional to assist them in the improvements. The hotels showed improvement during the repeat evaluation, but a significant increase in the percentage of overall adequacy was seen only in the food and beverages areas of the 12 hotels that used the intervention of an outsourced professional. The better percentage of adequacy in establishments with outsourced professional intervention underlines the importance of an external and impartial view of routine activities in the implementation of good handling practices.

  20. Genetic Susceptibility for Individual Cooperation Preferences: The Role of Monoamine Oxidase A Gene (MAOA) in the Voluntary Provision of Public Goods

    PubMed Central

    Mertins, Vanessa; Schote, Andrea B.; Hoffeld, Wolfgang; Griessmair, Michele; Meyer, Jobst

    2011-01-01

    In the context of social dilemmas, previous research has shown that human cooperation is mainly based on the social norm of conditional cooperation. While in most cases individuals behave according to such a norm, deviant behavior is no exception. Recent research further suggests that heterogeneity in social behavior might be associated with varying genetic predispositions. In this study, we investigated the relationship between individuals' behavior in a public goods experiment and the promoter-region functional repeat polymorphism in the monoamine oxidase A gene (MAOA). In a dynamic setting of increasing information about others' contributions, we analyzed differences in two main components of conditional cooperation, namely the players' own contribution and their beliefs regarding the contribution of other players. We showed that there is a significant association between individuals' behavior in a repeated public goods game and MAOA. Our results suggest that male carriers of the low activity alleles cooperate significantly less than those carrying the high activity alleles given a situation where subjects had to rely on their innate beliefs about others' contributions. With increasing information about the others' cooperativeness, the genetic effect diminishes. Furthermore, significant opposing effects for female subjects carrying two low activity alleles were observed. PMID:21698196

  1. Validation of the King's Sarcoidosis Questionnaire (KSQ) in a Dutch sarcoidosis population.

    PubMed

    Van Manen, Mirjam J G; Wapenaar, Monique; Strookappe, Bert; Drent, Marjolein; Elfferich, Marjon; de Vries, Jolanda; Gosker, Harry R; Birring, Surinder S; Patel, Amit S; van den Toorn, Leon; van den Blink, Bernt; Boomars, Karin; Hoitsma, Elske; Wijsenbeek, Marlies S

    2016-03-29

    The King's Sarcoidosis Questionnaire (KSQ) is a brief questionnaire assessing health status using five modules (General Health Status, Lung, Eyes, Skin, Medication) in patients with sarcoidosis. The KSQ was only validated in one English sarcoidosis cohort. The aim of this study was to validate the KSQ in a Dutch sarcoidosis population. The KSQ was translated according to international guidelines and tested in interviews with patients. Consecutive outpatients completed multiple questionnaires twice, two weeks apart. Construct validity, internal consistency and repeatability were determined. Of the 98 patients included 85 had lung, 22 skin and 24 eye disease. There was good construct validity of the KSQ General Health Status module against the World Health Organization Quality of Life-BREF questionnaire. The Medication module correlated weak to moderate with most questionnaires. The correlations with organ-specific questionnaires varied from strong for Eyes (r=0.75), Skin (r=-0.62) to moderate for Lung (r=-0.45 with MRC breathlessness scale). Internal consistency was good for all KSQ modules (Cronbach's α 0.72-0.93). Intraclass correlation coefficients (0.70-0.90) and Bland-Altman plots showed good repeatability of the KSQ. The Dutch KSQ is the first translation of the English KSQ, validated in a Dutch sarcoidosis population.

  2. A new approach to the measurement of pelvic asymmetry: proposed methods and reliability.

    PubMed

    Gnat, Rafael; Biały, Maciej

    2015-05-01

    This is a methodological study presenting a novel method of pelvic asymmetry (PA) measurement for use in the research laboratory setting. The purpose of the study is (1) to establish intrarater and interrater reliability of the proposed measures of PA, (2) to verify the influence of repeated measurements on the reliability, and (3) to assess correlation between the proposed measures of PA. Twelve healthy volunteers participated, and 2 teams of raters were involved. Registration of anatomic landmarks' positions in the optical motion capture system was repeated 3 times. Two asymmetry indexes were calculated: for pelvic torsion and for lateral pelvic tilt. Interclass correlation coefficients (ICCs), standard errors of measurement, and smallest detectable differences were used to describe the intrarater and interrater reliability of the 2 indexes. After 2 repeated registrations of pelvic landmarks' positions, the reliability of our asymmetry indexes was good and excellent. The ICCs for intrarater reliability ranged from 0.96 to 0.97; the ICCs for interrater reliability ranged 0.81 to 0.90. There was moderate, nonsignificant correlation between asymmetry indexes for pelvis torsion and for lateral pelvic tilt (r = 0.45, P = .14). The 2 proposed asymmetry indexes showed good and excellent intrarater and interrater reliability after 2 repeated registrations of pelvic landmarks' positions and thus may be useful in the research laboratory setting. However, these indexes are not strongly correlated, which suggests that the 2 types of PA may constitute different clinical entities. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  3. SEM-based overlay measurement between via patterns and buried M1 patterns using high-voltage SEM

    NASA Astrophysics Data System (ADS)

    Hasumi, Kazuhisa; Inoue, Osamu; Okagawa, Yutaka; Shao, Chuanyu; Leray, Philippe; Halder, Sandip; Lorusso, Gian; Jehoul, Christiane

    2017-03-01

    The miniaturization of semiconductors continues, importance of overlay measurement is increasing. We measured overlay with analysis SEM called Miracle Eye which can output ultrahigh acceleration voltage in 1998. Meanwhile, since 2006, we have been working on SEM based overlay measurement and developed overlay measurement function of the same layer using CD-SEM. Then, we evaluated overlay of the same layer pattern after etching. This time, in order to measure overlay after lithography, we evaluated the see-through overlay using high voltage SEM CV5000 released in October 2016. In collaboration between imec and Hitachi High-Technologies, we evaluated repeatability, TIS of SEM-OVL as well as correlation between SEM-OVL and Opt-OVL in the M1@ADI and V0@ADI process. Repeatability and TIS results are reasonable and SEM-OVL has good correlation with Opt-OVL. By overlay measurement using CV 5000, we got the following conclusions. (1)SEM_OVL results of both M1 and V0 at ADI show good correlation to OPT_OVL. (2)High voltage SEM can prove the measurement capability of a small pattern(Less than 1 2um) like device that can be placed in-die area. (3)"In-die SEM based overlay" shows possibility for high order control of scanner

  4. Sonoelastographic Features of the Patellar Ligament in Clinically Normal Dogs.

    PubMed

    Piccionello, Angela P; Serrani, Daniele; Busoni, Valeria; Salvaggio, Alberto; Bonazzi, Mattia; Bergamino, Chiara; Volta, Antonella

    2018-06-11

     This article describes the sonoelastographic features of the patellar ligament of sound dogs and tests feasibility, reproducibility and repeatability.  Clinically healthy medium-to-large breed dogs were enrolled. Sonoelastographic images of the patellar ligaments were obtained in lateral recumbency with the stifle flexed by an experienced operator and by a senior veterinary student. The elasticity colour map included red (soft), green (intermediate) and blue (hard). Tissue elasticity was measured by calculating the percentage of softness with dedicated software. Categorical, qualitative data analysis was performed using a weighted kappa statistic for repeatability and reproducibility. A categorical qualitative assessment was performed based on a grading scale of 1 to 5 (soft, mostly soft, intermediate, mostly hard and hard).  Fourteen clinically normal dogs were considered. A total of 28 patellar ligaments were examined. Overall, 25 of the patellar ligaments were graded as soft or mostly soft and the remaining 3 as intermediate. Repeatability was 86.2%, with a weighted kappa of 0.64 (good), for the well-trained sonographer and 83.3%, with a weighted kappa of 0.53 (moderate), for the senior student. Reproducibility was 86.2%, with a weighed kappa of 0.65 (good).  Sonoelastography of the canine patellar ligament is a feasible and reproducible technique. Patellar ligaments in clinically normal dogs showed highly elastic biomechanical properties. Schattauer GmbH Stuttgart.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nata, Iryanti Fatyasari, E-mail: yanti_tkunlam@yahoo.com; Irawan, Chairul; Mardina, Primata

    Highly sulfonated carbonaceous spheres with diameter of 100–500 nm can be generated by hydrothermal carbonization of glucose in the presence of hydroxyethylsulfonic acid and acrylic acid at 180 °C for 4 h. The acidity of the prepared carbonaceous sphere C4-SO{sub 3}H can reach 2.10 mmol/g. It was used as a solid acid catalyst for the hydrolysis of cornstarch. Total reducing sugar (TRS) concentration of 19.91 mg/mL could be obtained by hydrolyzing 20 mg/mL cornstarch at 150 °C for 6 h using C4-SO{sub 3}H as solid acid catalyst. The solid acid catalyst demonstrated good stability that only 9% decrease in TRSmore » concentration was observed after five repeat uses. The as-prepared carbon-based solid acid catalyst can be an environmentally benign replacement for homogeneous catalyst. - Highlights: • Carbon solid acid was successfully prepared by one-step hydrothermal carbonization. • The acrylic acid as monomer was effectively reduce the diameter size of particle. • The solid acid catalyst show good catalytic performance of starch hydrolysis. • The solid acid catalyst is not significantly deteriorated after repeated use.« less

  6. Prism under cover test in alternate fixation horizontal strabismus.

    PubMed

    Tejedor, Jaime; Gutiérrez-Carmona, Francisco José

    2018-02-01

    To evaluate the applicability of the prism under cover test (PUCT) to quantify manifest deviation in horizontal strabismus with alternate fixation when simultaneous prism and cover test (SPCT) is not feasible. Children aged 4-11 years, with alternate fixation horizontal strabismus and alternate prism and cover test (APCT) distance deviation (DD) up to 25 PD were eligible. In group 1 of the study, SPCT was not feasible (n = 18), whereas in group 2, it was feasible (n = 24). Refraction, PUCT, APCT, central/peripheral fusion, and stereoacuity were measured. Repeatability of PUCT, agreement between PUCT and SPCT, and Pearson correlations between variables were studied. In group 1, mean DD was 15.6 and 9.5 PD using APCT and PUCT, respectively (intraclass correlation, ICC: 0.90). Mean stereoacuity was 201.1 arc seconds. PUCT was better correlated with stereoacuity than APCT, but not significantly (p = 0.12). Coefficient of repeatability for PUCT was 3.4 PD. In group 2, mean DD was 17.6, 14.1, and 12.5 PD using APCT, PUCT, and SPCT, respectively. Mean stereoacuity was 285.9 arc seconds. Correlations APCT-PUCT (0.87), APCT-SPCT (0.82), and SPCT-PUCT (0.95) were significant. APCT did not show as good correlation with stereoacuity (0.58) as SPCT and PUCT (0.74 and 0.78, respectively). Concordance correlation coefficient between SPCT and PUCT was 0.91, and Bland Altman agreement between the two variables was also good. PUCT is a procedure with good repeatability, of interest in children to estimate manifest deviation when SPCT is not feasible, and in support of the diagnosis of monofixation syndrome.

  7. Design and characterization of a wearable macrobending fiber optic sensor for human joint angle determination

    NASA Astrophysics Data System (ADS)

    Silva, Ana S.; Catarino, André; Correia, Miguel V.; Frazão, Orlando

    2013-12-01

    The work presented here describes the development and characterization of intensity fiber optic sensor integrated in a specifically designed piece of garment to measure elbow flexion. The sensing head is based on macrobending incorporated in the garment, and the increase of curvature number was studied in order to investigate which scheme provided a good result in terms of sensitivity and repeatability. Results showed the configuration that assured a higher sensitivity (0.644 dBm/deg) and better repeatability was the one with four loops. Ultimately, this sensor can be used for rehabilitation purposes to monitor human joint angles, namely, elbow flexion on stroke survivors while performing the reach functional task, which is the most common upper-limb human gesture.

  8. Population Fisher information matrix and optimal design of discrete data responses in population pharmacodynamic experiments.

    PubMed

    Ogungbenro, Kayode; Aarons, Leon

    2011-08-01

    In the recent years, interest in the application of experimental design theory to population pharmacokinetic (PK) and pharmacodynamic (PD) experiments has increased. The aim is to improve the efficiency and the precision with which parameters are estimated during data analysis and sometimes to increase the power and reduce the sample size required for hypothesis testing. The population Fisher information matrix (PFIM) has been described for uniresponse and multiresponse population PK experiments for design evaluation and optimisation. Despite these developments and availability of tools for optimal design of population PK and PD experiments much of the effort has been focused on repeated continuous variable measurements with less work being done on repeated discrete type measurements. Discrete data arise mainly in PDs e.g. ordinal, nominal, dichotomous or count measurements. This paper implements expressions for the PFIM for repeated ordinal, dichotomous and count measurements based on analysis by a mixed-effects modelling technique. Three simulation studies were used to investigate the performance of the expressions. Example 1 is based on repeated dichotomous measurements, Example 2 is based on repeated count measurements and Example 3 is based on repeated ordinal measurements. Data simulated in MATLAB were analysed using NONMEM (Laplace method) and the glmmML package in R (Laplace and adaptive Gauss-Hermite quadrature methods). The results obtained for Examples 1 and 2 showed good agreement between the relative standard errors obtained using the PFIM and simulations. The results obtained for Example 3 showed the importance of sampling at the most informative time points. Implementation of these expressions will provide the opportunity for efficient design of population PD experiments that involve discrete type data through design evaluation and optimisation.

  9. Reliability and criterion-related validity of a new repeated agility test

    PubMed Central

    Makni, E; Jemni, M; Elloumi, M; Chamari, K; Nabli, MA; Padulo, J; Moalla, W

    2016-01-01

    The study aimed to assess the reliability and the criterion-related validity of a new repeated sprint T-test (RSTT) that includes intense multidirectional intermittent efforts. The RSTT consisted of 7 maximal repeated executions of the agility T-test with 25 s of passive recovery rest in between. Forty-five team sports players performed two RSTTs separated by 3 days to assess the reliability of best time (BT) and total time (TT) of the RSTT. The intra-class correlation coefficient analysis revealed a high relative reliability between test and retest for BT and TT (>0.90). The standard error of measurement (<0.50) showed that the RSTT has a good absolute reliability. The minimal detectable change values for BT and TT related to the RSTT were 0.09 s and 0.58 s, respectively. To check the criterion-related validity of the RSTT, players performed a repeated linear sprint (RLS) and a repeated sprint with changes of direction (RSCD). Significant correlations between the BT and TT of the RLS, RSCD and RSTT were observed (p<0.001). The RSTT is, therefore, a reliable and valid measure of the intermittent repeated sprint agility performance. As this ability is required in all team sports, it is suggested that team sports coaches, fitness coaches and sports scientists consider this test in their training follow-up. PMID:27274109

  10. Intra-Platform Repeatability and Inter-Platform Comparability of MicroRNA Microarray Technology

    PubMed Central

    Sato, Fumiaki; Tsuchiya, Soken; Terasawa, Kazuya; Tsujimoto, Gozoh

    2009-01-01

    Over the last decade, DNA microarray technology has provided a great contribution to the life sciences. The MicroArray Quality Control (MAQC) project demonstrated the way to analyze the expression microarray. Recently, microarray technology has been utilized to analyze a comprehensive microRNA expression profiling. Currently, several platforms of microRNA microarray chips are commercially available. Thus, we compared repeatability and comparability of five different microRNA microarray platforms (Agilent, Ambion, Exiqon, Invitrogen and Toray) using 309 microRNAs probes, and the Taqman microRNA system using 142 microRNA probes. This study demonstrated that microRNA microarray has high intra-platform repeatability and comparability to quantitative RT-PCR of microRNA. Among the five platforms, Agilent and Toray array showed relatively better performances than the others. However, the current lineup of commercially available microRNA microarray systems fails to show good inter-platform concordance, probably because of lack of an adequate normalization method and severe divergence in stringency of detection call criteria between different platforms. This study provided the basic information about the performance and the problems specific to the current microRNA microarray systems. PMID:19436744

  11. Seven rules to avoid the tragedy of the commons.

    PubMed

    Murase, Yohsuke; Baek, Seung Ki

    2018-07-14

    Cooperation among self-interested players in a social dilemma is fragile and easily interrupted by mistakes. In this work, we study the repeated n-person public-goods game and search for a strategy that forms a cooperative Nash equilibrium in the presence of implementation error with a guarantee that the resulting payoff will be no less than any of the co-players'. By enumerating strategic possibilities for n=3, we show that such a strategy indeed exists when its memory length m equals three. It means that a deterministic strategy can be publicly employed to stabilize cooperation against error with avoiding the risk of being exploited. We furthermore show that, for general n-person public-goods game, m ≥ n is necessary to satisfy the above criteria. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  12. A wide range and highly sensitive optical fiber pH sensor using polyacrylamide hydrogel

    NASA Astrophysics Data System (ADS)

    Pathak, Akhilesh Kumar; Singh, Vinod Kumar

    2017-12-01

    In the present study we report the fabrication and characterization of no-core fiber sensor (NCFS) using smart hydrogel coating for pH measurement. The no-core fiber (NCF) is stubbed between two single-mode fibers with SMA connector before immobilizing of smart hydrogel. The wavelength interrogation technique is used to calculate the sensitivity of the proposed sensor. The result shows a high sensitivity of 1.94 nm/pH for a wide range of pH values varied from 3 to 10 with a good linear response. In addition to high sensitivity, the fabricated sensor provides a fast response time with a good stability, repeatability and reproducibility.

  13. Repeated transsphenoidal surgery or gamma knife radiosurgery in recurrent cushing disease after transsphenoidal surgery.

    PubMed

    Bodaghabadi, Mohammad; Riazi, Hooman; Aran, Shima; Bitaraf, Mohammad Ali; Alikhani, Mazdak; Alahverdi, Mahmud; Mohamadi, Masoumeh; Shalileh, Keivan; Azar, Maziar

    2014-03-01

    This study compared Gamma knife radiosurgery (GKRS) and repeated transsphenoidal adenomectomy (TSA) to find the best approach for recurrence of Cushing disease (CD) after unsuccessful first TSA. Fifty-two patients with relapse of CD after TSA were enrolled and randomly underwent a second surgery or GKRS as the next therapeutic approach. They were followed for a mean period of 3.05 ± 0.8 years by physical examination and hormone measurement as well as magnetic resonance imaging. No significant difference was observed in sex ratio, mean age, adenoma type, follow-up duration, and initial hormone level between the two groups. No significant relationship was found between preoperative 24-hour free urine cortisol and disease-free months or tumor volume among both groups. Our statistical analysis showed higher recurrence-free interval in the GKRS group compared with TSA group. With longer recurrence-free interval, GKRS could be considered a good treatment alternative to repeated TSA in recurrent CD. Georg Thieme Verlag KG Stuttgart · New York.

  14. Measurement system analysis of viscometers used for drilling mud characterization

    NASA Astrophysics Data System (ADS)

    Mat-Shayuti, M. S.; Adzhar, S. N.

    2017-07-01

    Viscometers in the Faculty of Chemical Engineering, University Teknologi MARA, are subject to heavy utilization from the members of the faculty. Due to doubts surrounding their result integrity and maintenance management, Measurement System Analysis was executed. 5 samples of drilling muds with varied barite content from 5 - 25 weight% were prepared and their rheological properties determined in 3 trials by 3 operators using the viscometers. Gage Linearity and Bias Study were performed using Minitab software and the result shows high biases in the range of 19.2% to 38.7%, with non-linear trend along the span of measurements. Gage Repeatability & Reproducibility (Nested) analysis later produces Percent Repeatability & Reproducibility more than 7.7% and Percent Tolerance above 30%. Lastly, good and marginal Distinct Categories output are seen among the results. Despite acceptable performance of the measurement system in Distinct Categories, the poor results in accuracy, linearity, and Percent Repeatability & Reproducibility render the gage generally not capable. Improvement to the measurement system is imminent.

  15. Temporal and spatiotemporal variability in comprehensive forearm skin microcirculation assessment during occlusion protocols.

    PubMed

    Strömberg, Tomas; Sjöberg, Folke; Bergstrand, Sara

    2017-09-01

    Forearm skin hyperemia during release after brachial occlusion has been proposed for evaluating peripheral arterial disease and endothelial dysfunction. We used a novel fiberoptic system integrating Laser Doppler Flowmetry and Diffuse Reflectance Spectroscopy for a comprehensive pointwise model based microcirculation characterization. The aim was to evaluate and compare the temporal and the spatiotemporal variabilities in forearm skin microcirculation parameters (speed resolved perfusion; low speed <1mm/s, Perf SR, <1 ; mid-speed 1-10mm/s, high speed >10mm/s, and total perfusion (Perf SR, tot ); the concentration and oxygenation of red blood cells, C RBC and S O2 ). Ten healthy subjects underwent arterial and venous forearm occlusions (AO, VO), repeated within one week. The repeatability was calculated as the coefficient of variation (CV) and the agreement as the intra-class correlation coefficient (ICC). The temporal CVs for conventional perfusion, Perf conv , Perf SR, tot , C RBC and S O2 were 14%, 12%, 9% and 9%, respectively, while the ICC were >0.75 (excellent). The perfusion measures generally had a higher spatiotemporal than temporal variability, which was not the case for S O2 and C RBC . The corresponding spatiotemporal CVs were 33%, 32%, 18% and 15%, respectively. During VO, C RBC had a CV<35% and ICC>0.40 (fair-good), and after release this was the case for C RBC (AO and VO), S O2 (VO) and Perf SR, <1 (VO). In conclusion, the skin microcirculation parameters showed excellent temporal repeatability, while the spatiotemporal repeatability especially for perfusion was poorer. The parameters with acceptable repeatability and fair-good agreement were: C RBC during and after release of VO, the Perf SR, <1 after release of VO, the S O2 and the C RBC after release of AO. However, the value of these parameters in discriminating endothelial function remains to be studied. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Evaluation of the Nova StatSensor® XpressTM Creatinine Point-Of-Care Handheld Analyzer

    PubMed Central

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification. PMID:25886375

  17. Evaluation of the Nova StatSensor® Xpress(TM) Creatinine point-of-care handheld analyzer.

    PubMed

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification.

  18. One and done? Equality of opportunity and repeated access to scarce, indivisible medical resources

    PubMed Central

    2012-01-01

    Background Existing ethical guidelines recommend that, all else equal, past receipt of a medical resource (e.g. a scarce organ) should not be considered in current allocation decisions (e.g. a repeat transplantation). Discussion One stated reason for this ethical consensus is that formal theories of ethics and justice do not persuasively accept or reject repeated access to the same medical resources. Another is that restricting attention to past receipt of a particular medical resource seems arbitrary: why couldn’t one just as well, it is argued, consider receipt of other goods such as income or education? In consequence, simple allocation by lottery or first-come-first-served without consideration of any past receipt is thought to best afford equal opportunity, conditional on equal medical need. There are three issues with this view that need to be addressed. First, public views and patient preferences are less ambiguous than formal theories of ethics. Empirical work shows strong preferences for fairness in health care that have not been taken into account: repeated access to resources has been perceived as unfair. Second, while difficult to consider receipt of many other prior resources including non-medical resources, this should not be used a motive for ignoring the receipt of any and all goods including the focal resource in question. Third, when all claimants to a scarce resource are equally deserving, then use of random allocation seems warranted. However, the converse is not true: mere use of a randomizer does not by itself make the merits of all claimants equal. Summary My conclusion is that not ignoring prior receipt of the same medical resource, and prioritizing those who have not previously had access to the medical resource in question, may be perceived as fairer and more equitable by society. PMID:22624597

  19. One and done? Equality of opportunity and repeated access to scarce, indivisible medical resources.

    PubMed

    Huesch, Marco D

    2012-05-24

    Existing ethical guidelines recommend that, all else equal, past receipt of a medical resource (e.g. a scarce organ) should not be considered in current allocation decisions (e.g. a repeat transplantation). One stated reason for this ethical consensus is that formal theories of ethics and justice do not persuasively accept or reject repeated access to the same medical resources. Another is that restricting attention to past receipt of a particular medical resource seems arbitrary: why couldn't one just as well, it is argued, consider receipt of other goods such as income or education? In consequence, simple allocation by lottery or first-come-first-served without consideration of any past receipt is thought to best afford equal opportunity, conditional on equal medical need.There are three issues with this view that need to be addressed. First, public views and patient preferences are less ambiguous than formal theories of ethics. Empirical work shows strong preferences for fairness in health care that have not been taken into account: repeated access to resources has been perceived as unfair. Second, while difficult to consider receipt of many other prior resources including non-medical resources, this should not be used a motive for ignoring the receipt of any and all goods including the focal resource in question. Third, when all claimants to a scarce resource are equally deserving, then use of random allocation seems warranted. However, the converse is not true: mere use of a randomizer does not by itself make the merits of all claimants equal. My conclusion is that not ignoring prior receipt of the same medical resource, and prioritizing those who have not previously had access to the medical resource in question, may be perceived as fairer and more equitable by society.

  20. Repeatability and Reproducibility of Virtual Subjective Refraction.

    PubMed

    Perches, Sara; Collados, M Victoria; Ares, Jorge

    2016-10-01

    To establish the repeatability and reproducibility of a virtual refraction process using simulated retinal images. With simulation software, aberrated images corresponding with each step of the refraction process were calculated following the typical protocol of conventional subjective refraction. Fifty external examiners judged simulated retinal images until the best sphero-cylindrical refraction and the best visual acuity were achieved starting from the aberrometry data of three patients. Data analyses were performed to assess repeatability and reproducibility of the virtual refraction as a function of pupil size and aberrometric profile of different patients. SD values achieved in three components of refraction (M, J0, and J45) are lower than 0.25D in repeatability analysis. Regarding reproducibility, we found SD values lower than 0.25D in the most cases. When the results of virtual refraction with different pupil diameters (4 and 6 mm) were compared, the mean of differences (MoD) obtained were not clinically significant (less than 0.25D). Only one of the aberrometry profiles with high uncorrected astigmatism shows poor results for the M component in reproducibility and pupil size dependence analysis. In all cases, vision achieved was better than 0 logMAR. A comparison between the compensation obtained with virtual and conventional subjective refraction was made as an example of this application, showing good quality retinal images in both processes. The present study shows that virtual refraction has similar levels of precision as conventional subjective refraction. Moreover, virtual refraction has also shown that when high low order astigmatism is present, the refraction result is less precise and highly dependent on pupil size.

  1. Heralded high-efficiency quantum repeater with atomic ensembles assisted by faithful single-photon transmission

    NASA Astrophysics Data System (ADS)

    Li, Tao; Deng, Fu-Guo

    2015-10-01

    Quantum repeater is one of the important building blocks for long distance quantum communication network. The previous quantum repeaters based on atomic ensembles and linear optical elements can only be performed with a maximal success probability of 1/2 during the entanglement creation and entanglement swapping procedures. Meanwhile, the polarization noise during the entanglement distribution process is harmful to the entangled channel created. Here we introduce a general interface between a polarized photon and an atomic ensemble trapped in a single-sided optical cavity, and with which we propose a high-efficiency quantum repeater protocol in which the robust entanglement distribution is accomplished by the stable spatial-temporal entanglement and it can in principle create the deterministic entanglement between neighboring atomic ensembles in a heralded way as a result of cavity quantum electrodynamics. Meanwhile, the simplified parity-check gate makes the entanglement swapping be completed with unity efficiency, other than 1/2 with linear optics. We detail the performance of our protocol with current experimental parameters and show its robustness to the imperfections, i.e., detuning and coupling variation, involved in the reflection process. These good features make it a useful building block in long distance quantum communication.

  2. Heralded high-efficiency quantum repeater with atomic ensembles assisted by faithful single-photon transmission.

    PubMed

    Li, Tao; Deng, Fu-Guo

    2015-10-27

    Quantum repeater is one of the important building blocks for long distance quantum communication network. The previous quantum repeaters based on atomic ensembles and linear optical elements can only be performed with a maximal success probability of 1/2 during the entanglement creation and entanglement swapping procedures. Meanwhile, the polarization noise during the entanglement distribution process is harmful to the entangled channel created. Here we introduce a general interface between a polarized photon and an atomic ensemble trapped in a single-sided optical cavity, and with which we propose a high-efficiency quantum repeater protocol in which the robust entanglement distribution is accomplished by the stable spatial-temporal entanglement and it can in principle create the deterministic entanglement between neighboring atomic ensembles in a heralded way as a result of cavity quantum electrodynamics. Meanwhile, the simplified parity-check gate makes the entanglement swapping be completed with unity efficiency, other than 1/2 with linear optics. We detail the performance of our protocol with current experimental parameters and show its robustness to the imperfections, i.e., detuning and coupling variation, involved in the reflection process. These good features make it a useful building block in long distance quantum communication.

  3. Heralded high-efficiency quantum repeater with atomic ensembles assisted by faithful single-photon transmission

    PubMed Central

    Li, Tao; Deng, Fu-Guo

    2015-01-01

    Quantum repeater is one of the important building blocks for long distance quantum communication network. The previous quantum repeaters based on atomic ensembles and linear optical elements can only be performed with a maximal success probability of 1/2 during the entanglement creation and entanglement swapping procedures. Meanwhile, the polarization noise during the entanglement distribution process is harmful to the entangled channel created. Here we introduce a general interface between a polarized photon and an atomic ensemble trapped in a single-sided optical cavity, and with which we propose a high-efficiency quantum repeater protocol in which the robust entanglement distribution is accomplished by the stable spatial-temporal entanglement and it can in principle create the deterministic entanglement between neighboring atomic ensembles in a heralded way as a result of cavity quantum electrodynamics. Meanwhile, the simplified parity-check gate makes the entanglement swapping be completed with unity efficiency, other than 1/2 with linear optics. We detail the performance of our protocol with current experimental parameters and show its robustness to the imperfections, i.e., detuning and coupling variation, involved in the reflection process. These good features make it a useful building block in long distance quantum communication. PMID:26502993

  4. Fabric strain sensor integrated with CNPECs for repeated large deformation

    NASA Astrophysics Data System (ADS)

    Yi, Weijing

    Flexible and soft strain sensors that can be used in smart textiles for wearable applications are much desired. They should meet the requirements of low modulus, large working range and good fatigue resistance as well as good sensing performances. However, there were no commercial products available and the objective of the thesis is to investigate fabric strain sensors based on carbon nanoparticle (CNP) filled elastomer composites (CNPECs) for potential wearing applications. Conductive CNPECs were fabricated and investigated. The introduction of silicone oil (SO) significantly decreased modulus of the composites to less than 1 MPa without affecting their deformability and they showed good stability after heat treatment. With increase of CNP concentration, a percolation appeared in electrical resistivity and the composites can be divided into three ranges. I-V curves and impedance spectra together with electro-mechanical studies demonstrated a balance between sensitivity and working range for the composites with CNP concentrations in post percolation range, and were preferred for sensing applications only if the fatigue life was improved. Due to the good elasticity and failure resist property of knitted fabric under repeated extension, it was adopted as substrate to increase the fatigue life of the conductive composites. After optimization of processing parameters, the conductive fabric with CNP concentration of 9.0CNP showed linear I-V curves when voltage is in the range of -1 V/mm and 1 V/mm and negligible capacitive behavior when frequency below 103 Hz even with strain of 60%. It showed higher sensitivity due to the combination of nonlinear resistance-strain behavior of the CNPECs and non-even strain distribution of knitted fabric under extension. The fatigue life of the conductive fabric was greatly improved. Extended on the studies of CNPECs and the coated conductive fabrics, a fabric strain sensor was designed, fabricated and packaged. The Young's modulus of the packaged fabric strain sensor was less than 1 MPa; the strain gauge factor was 4.76 within the strain range of 0-40% and the hysteresis was 5.5%; the resistance relaxation was 5.56% with a constant strain of 40%; the fatigue life of the sensor was more than 100,000 cycles.

  5. Thermoluminescent properties of some phosphor glasses based on aluminum oxide.

    PubMed

    El Mesady, I; Khaled, N; Hussein, A; El Samman, H; Alawsh, S

    2016-12-01

    The transparent thermoluminescent aluminum oxide-based glass of 15Al 2 O 3 -35P 2 O 5 -25CaO-25Na 2 CO 3 , abbreviated as APCN (all in mol%) doped with different concentrations of SiO 2 from 0.0-500 ppm was prepared using a conventional melt-quenching technique. The TL sensitivities of the prepared glasses were investigated at 3 Gy γ-dose using a 60 Co source and measured at a heating rate 10 C/sec. The highest TL intensity of the material doped with SiO 2 was found at a concentration of 500 ppm (APCNSi 5 ). Deconvolution of the glow curve from APCNSi 5 resulted in four peaks at about 161, 194, 237 and 293 C with a Figure Of Merit (FOM) of 1.28%. The APCNSi 5 specimen had the best dosimetric properties when compared with the other samples. Reproducibility, repeatability, dose-response curve and fading effect were checked for peak 3, which appeared at about 237 C. The results displayed that the APCNSi 5 glass system was a low-Z material (Z eff  ≈ 10), and had good reproducibility and good repeatability. Peak 3 showed good linearity over a dose range up to 20 Gy (R 2  = 0.999) and sublinearity behaviour was found. The signal from APCNSi 5 faded by about 11% after 2 days post irradiation, therefore it showed almost no significant loss. Such properties make the newly prepared glasses suitable for and highly recommended for use in γ-dosimeters. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  6. Elliptical broken line method for calculating capillary density in nailfold capillaroscopy: Proposal and evaluation.

    PubMed

    Karbalaie, Abdolamir; Abtahi, Farhad; Fatemi, Alimohammad; Etehadtavakol, Mahnaz; Emrani, Zahra; Erlandsson, Björn-Erik

    2017-09-01

    Nailfold capillaroscopy is a practical method for identifying and obtaining morphological changes in capillaries which might reveal relevant information about diseases and health. Capillaroscopy is harmless, and seems simple and repeatable. However, there is lack of established guidelines and instructions for acquisition as well as the interpretation of the obtained images; which might lead to various ambiguities. In addition, assessment and interpretation of the acquired images are very subjective. In an attempt to overcome some of these problems, in this study a new modified technique for assessment of nailfold capillary density is introduced. The new method is named elliptic broken line (EBL) which is an extension of the two previously known methods by defining clear criteria for finding the apex of capillaries in different scenarios by using a fitted elliptic. A graphical user interface (GUI) is developed for pre-processing, manual assessment of capillary apexes and automatic correction of selected apexes based on 90° rule. Intra- and inter-observer reliability of EBL and corrected EBL is evaluated in this study. Four independent observers familiar with capillaroscopy performed the assessment for 200 nailfold videocapillaroscopy images, form healthy subject and systemic lupus erythematosus patients, in two different sessions. The results show elevation from moderate (ICC=0.691) and good (ICC=0.753) agreements to good (ICC=0.750) and good (ICC=0.801) for intra- and inter-observer reliability after automatic correction of EBL. This clearly shows the potential of this method to improve the reliability and repeatability of assessment which motivates us for further development of automatic tool for EBL method. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Retrieval and Sleep Both Counteract the Forgetting of Spatial Information

    ERIC Educational Resources Information Center

    Antony, James W.; Paller, Ken A.

    2018-01-01

    Repeatedly studying information is a good way to strengthen memory storage. Nevertheless, testing recall often produces superior long-term retention. Demonstrations of this testing effect, typically with verbal stimuli, have shown that repeated retrieval through testing reduces forgetting. Sleep also benefits memory storage, perhaps through…

  8. MEMS-based wide-bandwidth electromagnetic energy harvester with electroplated nickel structure

    NASA Astrophysics Data System (ADS)

    Sun, Shi; Dai, Xuhan; Sun, Yunna; Xiang, Xiaojian; Ding, Guifu; Zhao, Xiaolin

    2017-11-01

    A novel nickel-based nonlinear electromagnetic energy harvester has been designed, fabricated, and characterized in this work. Electroplated nickel is very suitable for a stretching-based mechanism to broaden the bandwidth due to its good process and mechanical properties. A strong hardening nonlinearity is induced due to the large deformation of the thin nickel based guided-beam structure. Combining the merits of both the mechanical properties and guided-beam structure, the energy harvester shows good bandwidth performance. It is found that increasing the thickness of the central platform could guarantee nonlinearity. Static and dynamic models of the energy harvester are simulated and validated. Test results show that the energy harvester has good repeatability without any destruction under a large deformation condition. At the acceleration of 0.5 g, comparative large bandwidths of 129 and 59 Hz are obtained for displacement and RMS output voltage, respectively. Power output of 3.4 µW and normalized power density of 125.92 µW cm-3 g-2 are achieved with the load resistance of 38 Ω.

  9. Directional learning and the provisioning of public goods.

    PubMed

    Nax, Heinrich H; Perc, Matjaž

    2015-01-26

    We consider an environment where players are involved in a public goods game and must decide repeatedly whether to make an individual contribution or not. However, players lack strategically relevant information about the game and about the other players in the population. The resulting behavior of players is completely uncoupled from such information, and the individual strategy adjustment dynamics are driven only by reinforcement feedbacks from each player's own past. We show that the resulting "directional learning" is sufficient to explain cooperative deviations away from the Nash equilibrium. We introduce the concept of k-strong equilibria, which nest both the Nash equilibrium and the Aumann-strong equilibrium as two special cases, and we show that, together with the parameters of the learning model, the maximal k-strength of equilibrium determines the stationary distribution. The provisioning of public goods can be secured even under adverse conditions, as long as players are sufficiently responsive to the changes in their own payoffs and adjust their actions accordingly. Substantial levels of public cooperation can thus be explained without arguments involving selflessness or social preferences, solely on the basis of uncoordinated directional (mis)learning.

  10. Viral delivery of C9orf72 hexanucleotide repeat expansions in mice leads to repeat-length-dependent neuropathology and behavioural deficits

    PubMed Central

    Herranz-Martin, Saul; Lewis, Katherine; Mulcahy, Padraig; Higginbottom, Adrian; Walker, Callum; Valenzuela, Isabel Martinez-Pena y; Coldicott, Ian; Shaw, Pamela J.

    2017-01-01

    ABSTRACT Intronic GGGGCC repeat expansions in C9orf72 are the most common genetic cause of amyotrophic lateral sclerosis (ALS) and frontotemporal dementia (FTD). Two major pathologies stemming from the hexanucleotide RNA expansions (HREs) have been identified in postmortem tissue: intracellular RNA foci and repeat-associated non-ATG dependent (RAN) dipeptides, although it is unclear how these and other hallmarks of disease contribute to the pathophysiology of neuronal injury. Here, we describe two novel lines of mice that overexpress either 10 pure or 102 interrupted GGGGCC repeats mediated by adeno-associated virus (AAV) and recapitulate the relevant human pathology and disease-related behavioural phenotypes. Similar levels of intracellular RNA foci developed in both lines of mice, but only mice expressing 102 repeats generated C9orf72 RAN pathology, neuromuscular junction (NMJ) abnormalities, dispersal of the hippocampal CA1, enhanced apoptosis, and deficits in gait and cognition. Neither line of mice, however, showed extensive TAR DNA-binding protein 43 (TDP-43) pathology or neurodegeneration. Our data suggest that RNA foci pathology is not a good predictor of C9orf72 RAN dipeptide formation, and that RAN dipeptides and NMJ dysfunction are drivers of C9orf72 disease pathogenesis. These AAV-mediated models of C9orf72-associated ALS/FTD will be useful tools for studying disease pathophysiology and developing new therapeutic approaches. PMID:28550099

  11. Supply- and Demand-Side Factors Influencing Utilization of Infant and Young Child Feeding Counselling Services in Viet Nam.

    PubMed

    Nguyen, Phuong H; Kim, Sunny S; Nguyen, Tuan T; Tran, Lan M; Hajeebhoy, Nemat; Frongillo, Edward A; Ruel, Marie T; Rawat, Rahul; Menon, Purnima

    2016-01-01

    Adequate utilization of services is critical to maximize the impact of counselling on infant and young child feeding (IYCF), but little is known about factors affecting utilization. Our study examined supply- and demand-side factors associated with the utilization of IYCF counselling services in Viet Nam. We used survey data from mothers with children <2y (n = 1,008) and health staff (n = 60) from the evaluation of a program that embedded IYCF counseling into the existing government health system. The frequency of never users, one-time users, repeat users, and achievers of the recommended minimum number of visits at health facilities were 45.1%, 13.0%, 28.4% and 13.5%, respectively. Poisson regression showed that demand-generation strategies, especially invitation cards, were the key factors determining one-time use (Prevalence ratio, PR 3.0, 95% CI: 2.2-4.2), repeated use (PR 3.2, 95% CI: 2.4-4.2), and achievement of minimum visits (PR 5.5, 95% CI: 3.6-8.4). Higher maternal education was associated with higher utilization both for one-time and repeated use. Being a farmer, belonging to an ethnic minority, and having a wasted child were associated with greater likelihood of achieving the minimum recommended number of visits, whereas child stunting or illness were not. Distance to health center was a barrier to repeated visits. Among supply-side factors, good counselling skills (PR: 1.3-1.8) was the most important factor associated with any service use, whereas longer employment duration and greater work pressure of health center staff were associated with lower utilization. Population attributable risk estimations showed that an additional 25% of the population would have achieved the minimum number of visits if exposed to three demand-generation strategies, and further increased to 49% if the health staff had good counseling skills and low work pressure. Our study provides evidence that demand-generation strategies are essential to increase utilization of facility-based IYCF counselling services in Viet Nam, and may be relevant for increasing and sustaining use of nutrition services in similar contexts.

  12. Supply- and Demand-Side Factors Influencing Utilization of Infant and Young Child Feeding Counselling Services in Viet Nam

    PubMed Central

    Nguyen, Phuong H.; Kim, Sunny S.; Nguyen, Tuan T.; Tran, Lan M.; Hajeebhoy, Nemat; Frongillo, Edward A.; Ruel, Marie T.; Rawat, Rahul; Menon, Purnima

    2016-01-01

    Adequate utilization of services is critical to maximize the impact of counselling on infant and young child feeding (IYCF), but little is known about factors affecting utilization. Our study examined supply- and demand-side factors associated with the utilization of IYCF counselling services in Viet Nam. We used survey data from mothers with children <2y (n = 1,008) and health staff (n = 60) from the evaluation of a program that embedded IYCF counseling into the existing government health system. The frequency of never users, one-time users, repeat users, and achievers of the recommended minimum number of visits at health facilities were 45.1%, 13.0%, 28.4% and 13.5%, respectively. Poisson regression showed that demand-generation strategies, especially invitation cards, were the key factors determining one-time use (Prevalence ratio, PR 3.0, 95% CI: 2.2–4.2), repeated use (PR 3.2, 95% CI: 2.4–4.2), and achievement of minimum visits (PR 5.5, 95% CI: 3.6–8.4). Higher maternal education was associated with higher utilization both for one-time and repeated use. Being a farmer, belonging to an ethnic minority, and having a wasted child were associated with greater likelihood of achieving the minimum recommended number of visits, whereas child stunting or illness were not. Distance to health center was a barrier to repeated visits. Among supply-side factors, good counselling skills (PR: 1.3–1.8) was the most important factor associated with any service use, whereas longer employment duration and greater work pressure of health center staff were associated with lower utilization. Population attributable risk estimations showed that an additional 25% of the population would have achieved the minimum number of visits if exposed to three demand-generation strategies, and further increased to 49% if the health staff had good counseling skills and low work pressure. Our study provides evidence that demand-generation strategies are essential to increase utilization of facility-based IYCF counselling services in Viet Nam, and may be relevant for increasing and sustaining use of nutrition services in similar contexts. PMID:26962856

  13. Verification of intensity modulated profiles using a pixel segmented liquid-filled linear array.

    PubMed

    Pardo, J; Roselló, J V; Sánchez-Doblado, F; Gómez, F

    2006-06-07

    A liquid isooctane (C8H18) filled ionization chamber linear array developed for radiotherapy quality assurance, consisting of 128 pixels (each of them with a 1.7 mm pitch), has been used to acquire profiles of several intensity modulated fields. The results were compared with film measurements using the gamma test. The comparisons show a very good matching, even in high gradient dose regions. The volume-averaging effect of the pixels is negligible and the spatial resolution is enough to verify these regions. However, some mismatches between the detectors have been found in regions where low-energy scattered photons significantly contribute to the total dose. These differences are not very important (in fact, the measurements of both detectors are in agreement using the gamma test with tolerances of 3% and 3 mm in most of those regions), and may be associated with the film energy dependence. In addition, the linear array repeatability (0.27% one standard deviation) is much better than the film one ( approximately 3%). The good repeatability, small pixel size and high spatial resolution make the detector ideal for the real time profile verification of high gradient beam profiles like those present in intensity modulated radiation therapy and radiosurgery.

  14. Performance of optical biosensor using alcohol oxidase enzyme for formaldehyde detection

    NASA Astrophysics Data System (ADS)

    Sari, A. P.; Rachim, A.; Nurlely, Fauzia, V.

    2017-07-01

    The recent issue in the world is the long exposure of formaldehyde which is can increase the risk of human health, therefore, that is very important to develop a device and method that can be optimized to detect the formaldehyde elements accurately, have a long lifetime and can be fabricated and produced in large quantities. A new and simple prepared optical biosensor for detection of formaldehyde in aqueous solutions using alcohol oxidase (AOX) enzyme was successfully fabricated. The poly-n-butyl acrylic-co-N-acryloxysuccinimide (nBA-NAS) membranes containing chromoionophore ETH5294 were used for immobilization of alcohol oxidase enzyme (AOX). Biosensor response was based on the colour change of chromoionophore as a result of enzymatic oxidation of formaldehyde and correlated with the detection concentration of formaldehyde. The performance of biosensor parameters were measured through the optical absorption value using UV-Vis spectrophotometer including the repeatability, reproducibility, selectivity and lifetime. The results showed that the prepared biosensor has good repeatability (RSD = 1.9 %) and good reproducibility (RSD = 2.1 %). The biosensor was selective formaldehyde with no disturbance by methanol, ethanol, and acetaldehyde, and also stable before 49 days and decrease by 41.77 % after 49 days.

  15. Sequence repeats and protein structure

    NASA Astrophysics Data System (ADS)

    Hoang, Trinh X.; Trovato, Antonio; Seno, Flavio; Banavar, Jayanth R.; Maritan, Amos

    2012-11-01

    Repeats are frequently found in known protein sequences. The level of sequence conservation in tandem repeats correlates with their propensities to be intrinsically disordered. We employ a coarse-grained model of a protein with a two-letter amino acid alphabet, hydrophobic (H) and polar (P), to examine the sequence-structure relationship in the realm of repeated sequences. A fraction of repeated sequences comprises a distinct class of bad folders, whose folding temperatures are much lower than those of random sequences. Imperfection in sequence repetition improves the folding properties of the bad folders while deteriorating those of the good folders. Our results may explain why nature has utilized repeated sequences for their versatility and especially to design functional proteins that are intrinsically unstructured at physiological temperatures.

  16. Kinematic Analysis of a Six-Degrees-of-Freedom Model Based on ISB Recommendation: A Repeatability Analysis and Comparison with Conventional Gait Model.

    PubMed

    Żuk, Magdalena; Pezowicz, Celina

    2015-01-01

    Objective. The purpose of the present work was to assess the validity of a six-degrees-of-freedom gait analysis model based on the ISB recommendation on definitions of joint coordinate systems (ISB 6DOF) through a quantitative comparison with the Helen Hays model (HH) and repeatability assessment. Methods. Four healthy subjects were analysed with both marker sets: an HH marker set and four marker clusters in ISB 6DOF. A navigated pointer was used to indicate the anatomical landmark position in the cluster reference system according to the ISB recommendation. Three gait cycles were selected from the data collected simultaneously for the two marker sets. Results. Two protocols showed good intertrial repeatability, which apart from pelvic rotation did not exceed 2°. The greatest differences between protocols were observed in the transverse plane as well as for knee angles. Knee internal/external rotation revealed the lowest subject-to-subject and interprotocol repeatability and inconsistent patterns for both protocols. Knee range of movement in transverse plane was overestimated for the HH set (the mean is 34°), which could indicate the cross-talk effect. Conclusions. The ISB 6DOF anatomically based protocol enabled full 3D kinematic description of joints according to the current standard with clinically acceptable intertrial repeatability and minimal equipment requirements.

  17. Enhancement of humidity sensitivity of graphene through functionalization with polyethylenimine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ben Aziza, Zeineb; School of Electrical and Electronics Engineering, Nanyang Technological University, Block S1, 50 Nanyang Avenue, Singapore 639798; XLIM UMR 7252 Université de Limoges/CNRS, 123 Avenue Albert Thomas, 87060 Limoges

    2015-09-28

    In this work, we show that the sensing performance of graphene based humidity sensors can be largely improved through polymer functionalization. Chemical vapor deposited graphene is functionalized with amine rich polymer, leading to electron transfer from amine groups in the polymer to graphene. The functionalized graphene humidity sensor has demonstrated good sensitivity, recovery, and repeatability. Charge transfer between the functionalized graphene and water molecules and the sensing mechanism are studied systemically using field effect transistor geometry and scanning Kelvin probe microscopy.

  18. Identification and characterization of short tandem repeats in the Tibetan macaque genome based on resequencing data.

    PubMed

    Liu, San-Xu; Hou, Wei; Zhang, Xue-Yan; Peng, Chang-Jun; Yue, Bi-Song; Fan, Zhen-Xin; Li, Jing

    2018-07-18

    The Tibetan macaque, which is endemic to China, is currently listed as a Near Endangered primate species by the International Union for Conservation of Nature (IUCN). Short tandem repeats (STRs) refer to repetitive elements of genome sequence that range in length from 1-6 bp. They are found in many organisms and are widely applied in population genetic studies. To clarify the distribution characteristics of genome-wide STRs and understand their variation among Tibetan macaques, we conducted a genome-wide survey of STRs with next-generation sequencing of five macaque samples. A total of 1 077 790 perfect STRs were mined from our assembly, with an N50 of 4 966 bp. Mono-nucleotide repeats were the most abundant, followed by tetra- and di-nucleotide repeats. Analysis of GC content and repeats showed consistent results with other macaques. Furthermore, using STR analysis software (lobSTR), we found that the proportion of base pair deletions in the STRs was greater than that of insertions in the five Tibetan macaque individuals (P<0.05, t-test). We also found a greater number of homozygous STRs than heterozygous STRs (P<0.05, t-test), with the Emei and Jianyang Tibetan macaques showing more heterozygous loci than Huangshan Tibetan macaques. The proportion of insertions and mean variation of alleles in the Emei and Jianyang individuals were slightly higher than those in the Huangshan individuals, thus revealing differences in STR allele size between the two populations. The polymorphic STR loci identified based on the reference genome showed good amplification efficiency and could be used to study population genetics in Tibetan macaques. The neighbor-joining tree classified the five macaques into two different branches according to their geographical origin, indicating high genetic differentiation between the Huangshan and Sichuan populations. We elucidated the distribution characteristics of STRs in the Tibetan macaque genome and provided an effective method for screening polymorphic STRs. Our results also lay a foundation for future genetic variation studies of macaques.

  19. Repeated partial endoscopic resections as treatment for two patients with inoperable tracheal tumours

    PubMed Central

    Nakratzas, G.; Wagenaar, J. P. M.; Reintjes, M.; Scheffer, E.; Swierenga, J.

    1974-01-01

    Nakratzas, G., Wagenaar, J. P. M., Reintjes, M., Scheffer, E., and Swierenga, J. (1974).Thorax, 29, 125-131. Repeated partial endoscopic resections as treatment for two patients with inoperable tracheal tumours. Two cases of tracheal tumour are described, one a carcinoid and the other an adenoid cystic carcinoma (cylindroma). Both patients were treated by repeated partial bronchoscopic resections. The patients are in good health nine and three years respectively after treatment. Images PMID:4363463

  20. [Development and medical application of Er-YAG laser].

    PubMed

    Okamoto, Y; Kobayashi, A; Awazu, A; Ogino, H; Ban, T

    1993-09-01

    Result of developments of Er-YAG laser and its delivery system were reported. Er-YAG laser's wavelength is 2.94 microns, the beam absorption rate by water is higher than other laser beam. Er-YAG laser has repeated pulse oscillation, pulse width is 400 mu, sec, the repeat frequency is between 5 to 10 pulse per second. The mean power is 4 W maximum, 10 pps. The fibers of laser are made of zirconium-F-glass. We carried out a study on the possible application of the Er-YAG laser on the rabbit arteries and myocardium and human arteries were examined in vitro. Very clear cuts were observed on the histological examination. There were no evidence of thermal damage, no carbonization on the sharp cutting surface. Experimental result showed that Er-YAG lasers had good potential for angioplastic laser.

  1. Mapping methane plumes and the delta C-13 composition of anthropogenic sources in southwest Germany

    NASA Astrophysics Data System (ADS)

    Schmidt, Martina; Yeman, Christiane; Dinger, Florian; Ars, Sebastien; Yver Kwok, Camille

    2016-04-01

    A mobile analyser based on Cavity-Ring-Down Spectroscopy was installed on a vehicle, together with a GPS receiver. This allows us to measure atmospheric methane and carbon dioxide mole fractions and the C-13 isotopes of both gases while driving. Methane mole fraction measurements show a good repeatability even for high frequency measurements whereas the 13CH4 measurements need a longer averaging time of 1 minute for 1 ‰ repeatability and 15 minutes for 0.23 ‰ repeatability. Driving through an emission plume, the signal is typically only 60 seconds long. To overcome the precision problem for the isotope measurements we filled a 25 m tubing when driving through the plume, which was then flushed back through our analyser during 30 minutes. During several campaigns we visited a land fill site, a biogas plant, a dairy cow farm and a natural gas storage and measured an averaged isotopic methane signature(C-13) of -58.3 ±3 ‰, -62.5 ± 1‰, -62.2 ± 2‰, -51 ± 7‰, respectively.

  2. Effects of phonological contrast on auditory word discrimination in children with and without reading disability: A magnetoencephalography (MEG) study

    PubMed Central

    Wehner, Daniel T.; Ahlfors, Seppo P.; Mody, Maria

    2007-01-01

    Poor readers perform worse than their normal reading peers on a variety of speech perception tasks, which may be linked to their phonological processing abilities. The purpose of the study was to compare the brain activation patterns of normal and impaired readers on speech perception to better understand the phonological basis in reading disability. Whole-head magnetoencephalography (MEG) was recorded as good and poor readers, 7-13 years of age, performed an auditory word discrimination task. We used an auditory oddball paradigm in which the ‘deviant’ stimuli (/bat/, /kat/, /rat/) differed in the degree of phonological contrast (1 vs. 3 features) from a repeated standard word (/pat/). Both good and poor readers responded more slowly to deviants that were phonologically similar compared to deviants that were phonologically dissimilar to the standard word. Source analysis of the MEG data using Minimum Norm Estimation (MNE) showed that compared to good readers, poor readers had reduced left-hemisphere activation to the most demanding phonological condition reflecting their difficulties with phonological processing. Furthermore, unlike good readers, poor readers did not show differences in activation as a function of the degree of phonological contrast. These results are consistent with a phonological account of reading disability. PMID:17675109

  3. Surface plasmon resonance sensor for antibiotics detection based on photo-initiated polymerization molecularly imprinted array.

    PubMed

    Luo, Qiaohui; Yu, Neng; Shi, Chunfei; Wang, Xiaoping; Wu, Jianmin

    2016-12-01

    A surface plasmon resonance (SPR) sensor combined with nanoscale molecularly imprinted polymer (MIP) film as recognition element was developed for selective detection of the antibiotic ciprofloxacin (CIP). The MIP film on SPR sensor chip was prepared by in situ photo-initiated polymerization method which has the advantages of short polymerization time, controllable thickness and good uniformity. The surface wettability and thickness of MIP film on SPR sensor chip were characterized by static contact angle measurement and stylus profiler. The MIP-SPR sensor exhibited high selectivity, sensitivity and good stability for ciprofloxacin. The imprinting factors of the MIP-SPR sensor to ciprofloxacin and its structural analogue ofloxacin were 2.63 and 3.80, which is much higher than those to azithromycin, dopamine and penicillin. The SPR response had good linear relation with CIP concentration over the range 10 -11 -10 -7 molL -1 . The MIP-SPR sensor also showed good repeatability and stability during cyclic detections. On the basis of the photo-initiated polymerization method, a surface plasmon resonance imaging (SPRi) chip modified with three types of MIP sensing spots was fabricated. The MIPs-SPRi sensor shows different response patterns to ciprofloxacin and azithromycin, revealing the ability to recognize different antibiotic molecules. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Reasons for and functional results of repeated hip arthroscopy: A continuous prospective study of 17 revisions out of 295 primary hip arthroscopies at mean 28months' follow-up.

    PubMed

    Tissot, C; Merlini, L; Mercier, M; Bonin, N

    2017-09-01

    The rate of iterative arthroscopy has been increasing over the last decade as the technique has grown. The results of and reasons for these revision procedures, however, are not exactly known. We therefore conducted a prospective study to shed light on: 1) functional results and patient satisfaction following repeated arthroscopy, and 2) the relevant indications. Functional scores and patient satisfaction increase following repeated arthroscopy. MATERIALS AND METHOD: A single-center continuous prospective study without control group included patients undergoing repeated hip arthroscopy between September 2010 and September 2014, with a mean 28months' follow-up (median, 23.3months; range, 12-62months). Preoperative and follow-up functional assessment used the modified Harris hip, WOMAC and Christensen (NHAS) questionnaires, and a satisfaction scale. On etiological analysis, repeated arthroscopy was indicated if a cause of recurrent or persistent pain accessible to arthroscopic treatment was identified. Seventeen patients were included out of 295 primary arthroscopies (5.7%): 9 male, 8 female; median age, 29.6years (range, 16-48years). Indications for primary arthroscopy comprised 13 cases of femoroacetabular impingement, 3 labrum lesions with instability, 1 chondromatosis and 1 case of osteoarthritis. Eleven of the 17 primary lesions showed persistence, including 9 of the 13 cases of femoroacetabular impingement. There were 3 failures in 17 repeated arthroscopies. All functional scores improved, with a gain of 7 points (P<0.06) on modified Harris hip score, 25 points (P<0.0006) on WOMAC score, and 27 points (P<0.001) on NHAS score. Ten of the 17 patients were satisfied or very satisfied with the repeated arthroscopy (59%). Although less good than on primary arthroscopy, functional results on repeated hip arthroscopy were satisfactory in the short term. The main reason for repeated arthroscopy was persistence of initial abnormality due to insufficient treatment. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  5. Reproducibility and repeatability of peripheral microvascular assessment using iontophoresis in conjunction with laser Doppler imaging.

    PubMed

    Jadhav, Sachin; Sattar, Naveed; Petrie, John R; Cobbe, Stuart M; Ferrell, William R

    2007-09-01

    Interrogation of peripheral vascular function is increasingly recognized as a noninvasive surrogate marker for coronary vascular function and carries with it important prognostic information regarding future cardiovascular risk. Laser Doppler imaging (LDI) is a completely noninvasive method for looking at peripheral microvascular function. We sought to look at reproducibility and repeatability of LDI-derived assessment of peripheral microvascular function between arms and 8 weeks apart. We used LDI in conjunction with iontophoretic application of ACh and SNP to look at endothelium-dependent and -independent microvascular function, respectively, in a mixture of women with cardiac syndrome X and healthy volunteers. We looked at variation between arms (n = 40) and variation at 8 weeks apart (n = 22). When measurements were corrected for skin resistance, there was nonsignificant variation between arms for ACh (2.7%) and SNP (3.8%) and nonsignificant temporal variation for ACh (3.5%) and SNP (4.7%). Construction of Bland-Altman plots reinforce that measurements have good repeatability. Elimination of the baseline perfusion response had deleterious effects on repeatability. LDI can be used to assess peripheral vascular response with good repeatability as long as measurements are corrected for skin resistance, which affects drug delivery. This has important implications for the future use of LDI.

  6. Assessment of the repeatability and border-plate effects of the B158/B60 enzyme-linked-immunosorbent assay for the detection of circulating antigens (Ag-ELISA) of Taenia saginata.

    PubMed

    Jansen, Famke; Dorny, Pierre; Berkvens, Dirk; Van Hul, Anke; Van den Broeck, Nick; Makay, Caroline; Praet, Nicolas; Gabriël, Sarah

    2016-08-30

    The monoclonal antibody-based circulating antigen detecting ELISA (B158/B60 Ag-ELISA) has been used elaborately in several studies for the diagnosis of human, bovine and porcine cysticercosis. Interpretation of test results requires a good knowledge of the test characteristics, including the repeatability and the effect of the borders of the ELISA plates. Repeatability was tested for 4 antigen-negative and 5 antigen-positive reference bovine serum samples by calculating the Percentage Coefficient of Variation (%CV) within and between plates, within and between runs, overall, for two batches of monoclonal antibodies and by 2 laboratory technicians. All CV values obtained were below 20% (except one: 24.45%), which indicates a good repeatability and a negligible technician error. The value of 24.45% for indicating the variability between batches of monoclonal antibodies for one positive sample is still acceptable for repeatability measures. Border effects were determined by calculating the %CV values between the inner and outer wells of one plate for 2 positive serum samples. Variability is a little more present in the outer wells but this effect is very small and no significant border effect was found. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Repetitive Elements May Comprise Over Two-Thirds of the Human Genome

    PubMed Central

    de Koning, A. P. Jason; Gu, Wanjun; Castoe, Todd A.; Batzer, Mark A.; Pollock, David D.

    2011-01-01

    Transposable elements (TEs) are conventionally identified in eukaryotic genomes by alignment to consensus element sequences. Using this approach, about half of the human genome has been previously identified as TEs and low-complexity repeats. We recently developed a highly sensitive alternative de novo strategy, P-clouds, that instead searches for clusters of high-abundance oligonucleotides that are related in sequence space (oligo “clouds”). We show here that P-clouds predicts >840 Mbp of additional repetitive sequences in the human genome, thus suggesting that 66%–69% of the human genome is repetitive or repeat-derived. To investigate this remarkable difference, we conducted detailed analyses of the ability of both P-clouds and a commonly used conventional approach, RepeatMasker (RM), to detect different sized fragments of the highly abundant human Alu and MIR SINEs. RM can have surprisingly low sensitivity for even moderately long fragments, in contrast to P-clouds, which has good sensitivity down to small fragment sizes (∼25 bp). Although short fragments have a high intrinsic probability of being false positives, we performed a probabilistic annotation that reflects this fact. We further developed “element-specific” P-clouds (ESPs) to identify novel Alu and MIR SINE elements, and using it we identified ∼100 Mb of previously unannotated human elements. ESP estimates of new MIR sequences are in good agreement with RM-based predictions of the amount that RM missed. These results highlight the need for combined, probabilistic genome annotation approaches and suggest that the human genome consists of substantially more repetitive sequence than previously believed. PMID:22144907

  8. Inter and intra-observer reliability in assessment of the position of the lateral sesamoid in determining the severity of hallux valgus.

    PubMed

    Panchani, Sunil; Reading, Jonathan; Mehta, Jaysheel

    2016-06-01

    The position of the lateral sesamoid on standard dorso-plantar weight bearing radiographs, with respect to the lateral cortex of the first metatarsal, has been shown to correlate well with the degree of the hallux valgus angle. This study aimed to assess the inter- and intra-observer error of this new classification system. Five orthopaedic consultants and five trainee orthopaedic surgeons were recruited to assess and document the degree of displacement of the lateral sesamoid on 144 weight-bearing dorso-plantar radiographs on two separate occasions. The severity of hallux valgus was defined as normal (0%), mild (≤50%), moderate (51-≤99%) or severe (≥100%) depending on the percentage displacement of the lateral sesamoid body from the lateral cortical border of the first metatarsal. Consultant intra-observer variability showed good agreement between repeated assessment of the radiographs (mean Kappa=0.75). Intra-observer variability for trainee orthopaedic surgeons also showed good agreement with a mean Kappa=0.73. Intraclass correlations for consultants and trainee surgeons was also high. The new classification system of assessing the severity of hallux valgus shows high inter- and intra-observer variability with good agreement and reproducibility between surgeons of consultant and trainee grades. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Inter-laboratory validation of bioaccessibility testing for metals.

    PubMed

    Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R

    2014-10-01

    Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. SU-E-T-492: Implementing a Method for Brain Irradiation in Rats Utilizing a Commercially Available Radiosurgery Irradiator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cates, J; Drzymala, R

    2014-06-01

    Purpose: The purpose of the study was to implement a method for accurate rat brain irradiation using the Gamma Knife Perfexion unit. The system needed to be repeatable, efficient, and dosimetrically and spatially accurate. Methods: A platform (“rat holder”) was made such that it is attachable to the Leskell Gamma Knife G Frame. The rat holder utilizes two ear bars contacting bony anatomy and a front tooth bar to secure the rat. The rat holder fits inside of the Leskell localizer box, which utilizes fiducial markers to register with the GammaPlan planning system. This method allows for accurate, repeatable setup.Amore » cylindrical phantom was made so that film can be placed axially in the phantom. We then acquired CT image sets of the rat holder and localizer box with both a rat and the phantom. Three treatment plans were created: a plan on the rat CT dataset, a phantom plan with the same prescription dose as the rat plan, and a phantom plan with the same delivery time as the rat plan. Results: Film analysis from the phantom showed that our setup is spatially accurate and repeatable. It is also dosimetrically accurate, with an difference between predicted and measured dose of 2.9%. Film analysis with prescription dose equal between rat and phantom plans showed a difference of 3.8%, showing that our phantom is a good representation of the rat for dosimetry purposes, allowing for +/- 3mm diameter variation. Film analysis with treatment time equal showed an error of 2.6%, which means we can deliver a prescription dose within 3% accuracy. Conclusion: Our method for irradiation of rat brain has been shown to be repeatable, efficient, and accurate, both dosimetrically and spatially. We can treat a large number of rats efficiently while delivering prescription doses within 3% at millimeter level accuracy.« less

  11. Evaluation of the Microsemi CRP, an automated hematology analyzer for rapid 3-part WBC differential and CRP using whole blood.

    PubMed

    Nomura, N; Saito, K; Ikeda, M; Yuasa, S; Pastore, M; Chabert, C; Kono, E; Sakai, A; Tanaka, H; Ikemoto, T; Takubo, T

    2015-08-01

    We evaluated the basic performance of Microsemi CRP, an unique automated hematology analyzer which can simultaneously measure CBC including 3-part WBC differential (3-Diff) and CRP using whole blood treated with EDTA-2K anticoagulant. We found that it produced generally the acceptable results for all parameters performed (repeatability, reproducibility, linearity, interference effect, carry over, and correlation) using control materials, fresh human whole bloods, and serum samples. CBC data examined using Microsemi CRP showed the good correlation with the previous model, Micros CRP200 (r ≧ 0.9), and also those obtained using the routine analyzer, ADVIA 2120i (r ≧ 0.989). Concerning the 3-Diff, both GRA (%) and LYM (%) showed the excellent correlation coefficient between Microsemi CRP and Micros CRP200 (r ≧ 0.992) as well as ADVIA 2120i (r ≧ 0.957). MON (%) showed good correlation between Microsemi CRP and Micros CRP200 (r = 0.959), but lower correlation between Microsemi CRP and ADVIA 2120 i (r = 0.471). CRP data showed the good correlation with HITACHI7600 (r ≧ 0.997) and Micros CRP200 (r ≧ 0.997). From these findings, we concluded that Microsemi CRP seemed the convenient laboratory analyzer in the setting of point of care testing (POCT) especially at NICU or primary care unit. © 2014 John Wiley & Sons Ltd.

  12. Measurement properties of continuous text reading performance tests.

    PubMed

    Brussee, Tamara; van Nispen, Ruth M A; van Rens, Ger H M B

    2014-11-01

    Measurement properties of tests to assess reading acuity or reading performance have not been extensively evaluated. This study aims to provide an overview of the literature on available continuous text reading tests and their measurement properties. A literature search was performed in PubMed, Embase and PsycInfo. Subsequently, information on design and content of reading tests, study design and measurement properties were extracted using consensus-based standards for selection of health measurement instruments. Quality of studies, reading tests and measurement properties were systematically assessed using pre-specified criteria. From 2334 identified articles, 20 relevant articles were found on measurement properties of three reading tests in various languages: IReST, MNread Reading Test and Radner Reading Charts. All three reading tests scored high on content validity. Reproducibility studies (repeated measurements between different testing sessions) of the IReST and MNread of commercially available reading tests in different languages were missing. The IReST scored best on inter-language comparison, the MNread scored well in repeatability studies (repeated measurements under the same conditions) and the Radner showed good reproducibility in studies. Although in daily practice there are other continuous text reading tests available meeting the criteria of this review, measurement properties were described in scientific studies for only three of them. Of the few available studies, the quality and content of study design and methodology used varied. For testing existing reading tests and the development of new ones, for example in other languages, we make several recommendations, including careful description of patient characteristics, use of objective and subjective lighting levels, good control of working distance, documentation of the number of raters and their training, careful documentation of scoring rules and the use of Bland-Altman analyses or similar for reproducibility and repeatability studies. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  13. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation

    PubMed Central

    Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo

    2017-01-01

    AIM To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). METHODS Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. RESULTS Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected. PMID:29181318

  14. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation.

    PubMed

    Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo

    2017-01-01

    To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  15. Co-action provides rational basis for the evolutionary success of Pavlovian strategies

    NASA Astrophysics Data System (ADS)

    Sasidevan, V.; Sinha, Sitabhra

    2016-08-01

    Strategies incorporating direct reciprocity, e.g., Tit-for-Tat and Pavlov, have been shown to be successful for playing the Iterated Prisoners Dilemma (IPD), a paradigmatic problem for studying the evolution of cooperation among non-kin individuals. However it is an open question whether such reciprocal strategies can emerge as the rational outcome of repeated interactions between selfish agents. Here we show that adopting a co-action perspective, which takes into account the symmetry between agents - a relevant consideration in biological and social contexts - naturally leads to such a strategy. For a 2-player IPD, we show that the co-action solution corresponds to the Pavlov strategy, thereby providing a rational basis for it. For an IPD involving many players, an instance of the Public Goods game where cooperation is generally considered to be harder to achieve, we show that the cooperators always outnumber defectors in the co-action equilibrium. This can be seen as a generalization of Pavlov to contests involving many players. In general, repeated interactions allow rational agents to become aware of the inherent symmetry of their situation, enabling them to achieve robust cooperation through co-action strategies - which, in the case of IPD, is a reciprocal Pavlovian one.

  16. A case report of desmoid tumour-a forgotten aspect of FAP?

    PubMed

    Xuereb, Sarah; Xuereb, Rachel; Buhagiar, Chiara; Gauci, Jonathan; Magri, Claude

    2017-01-01

    Desmoid tumours are locally aggressive tumours which are common in Familial Adenomatous Polyposis (FAP). A 20-year old Familial Adenomatous Polyposis (FAP) patient presented with abdominal pain and distention. Abdominal imaging showed small bowel obstruction and hydronephrosis due to a pelvic mass. This mass showed significant enlargement on repeat imaging, and a diagnostic biopsy confirmed desmoid tumour. The mass was deemed unresectable and he was initially started on sulindac and raloxifene. Repeat imaging however showed further enlargement of the tumour, and therefore vinblastine+methotrexate chemotherapy was commenced, with a good response. FAP is an autosomal dominant condition caused by a germline mutation in the adenomatous polyposis coli (APC) gene. Gardner's syndrome is also caused by a mutation in the APC gene, and is now considered a different phenotypic presentation of FAP. Desmoid tumours are initially kept under observation while their size remains stable. Treatment options for enlarging desmoids tumours include surgery (first-line), radiotherapy, and systemic therapy with non-cytotoxic and cytotoxic therapy. FAP patients should be examined regularly post-panprocotocolectomy, since desmoid tumours may arise. The presence of epidermal cysts in this FAP patient suggests a diagnosis of Gardner's syndrome. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  17. Hydrogen peroxide biosensor based on hemoglobin immobilized at graphene, flower-like zinc oxide, and gold nanoparticles nanocomposite modified glassy carbon electrode.

    PubMed

    Xie, Lingling; Xu, Yuandong; Cao, Xiaoyu

    2013-07-01

    In this work, a highly sensitive hydrogen peroxide (H2O2) biosensor based on immobilization of hemoglobin (Hb) at Au nanoparticles (AuNPs)/flower-like zinc oxide/graphene (AuNPs/ZnO/Gr) composite modified glassy carbon electrode (GCE) was constructed, where ZnO and Au nanoparticles were modified through layer-by-layer onto Gr/GCE. Flower-like ZnO nanoparticles could be easily prepared by adding ethanol to the precursor solution having higher concentration of hydroxide ions. The Hb/AuNPs/ZnO/Gr composite film showed a pair of well-defined, quasi-reversible redox peaks with a formal potential (E(0)) of -0.367 V, characteristic features of heme redox couple of Hb. The electron transfer rate constant (k(s)) of immobilized Hb was 1.3 s(-1). The developed biosensor showed a very fast response (<2 s) toward H2O2 with good sensitivity, wide linear range, and low detection limit of 0.8 μM. The fabricated biosensor showed interesting features, including high selectivity, acceptable stability, good reproducibility, and repeatability along with excellent conductivity, facile electron mobility of Gr, and good biocompatibility of ZnO and AuNPs. The fabrication method of this biosensor was simple and effective for determination of H2O2 in real samples with quick response, good sensitivity, high selectivity, and acceptable recovery. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. [Determination of 27 elements in Maca nationality's medicine by microwave digestion ICP-MS].

    PubMed

    Yu, Gui-fang; Zhong, Hai-jie; Hu, Jun-hua; Wang, Jing; Huang, Wen-zhe; Wang, Zhen-zhong; Xiao, Wei

    2015-12-01

    An analysis method has been established to test 27 elements (Li, Be, B, Mg, Al, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Sr, Mo, Cd, Sn, Sb, Ba, La, Hg, Pb, Bi) in Maca nationality's medicine with microwave digestion-ICP-MS. Sample solutions were analyzed by ICP-MS after microwave digestion, and the contents of elements were calculated according to their calibration curves, and internal standard method was adopted to reduce matrix effect and other interference effects. The experimental results showed that the linear relations of all the elements were very good; the correlation coefficient (r) was 0.9994-1.0000 (Hg was 0.9982) ; the limits of detection were 0.003-2.662 microg x L(-1); the relative standard deviations for all elements of reproducibility were lower than 5% (except the individual elements); the recovery rate were 78.5%-123.7% with RSD lower than 5% ( except the individual elements). The analytical results of standard material showed acceptable agreement with the certified values. This method was applicable to determinate the contents of multi-elements in Maca which had a high sensitivity, good specificity and good repeatability, and provide basis for the quality control of Maca.

  19. Miniaturized flow system based on enzyme modified PMMA microreactor for amperometric determination of glucose.

    PubMed

    Cerdeira Ferreira, Luís Marcos; da Costa, Eric Tavares; do Lago, Claudimir Lucio; Angnes, Lúcio

    2013-09-15

    This paper describes the development of a microfluidic system having as main component an enzymatic reactor constituted by a microchannel assembled in poly(methyl methacrylate) (PMMA) substrate connected to an amperometric detector. A CO2 laser engraving machine was used to make the channels, which in sequence were thermally sealed. The internal surfaces of the microchannels were chemically modified with polyethyleneimine (PEI), which showed good effectiveness for the immobilization of the glucose oxidase enzyme using glutaraldehyde as crosslinking agent, producing a very effective microreactor for the detection of glucose. The hydrogen peroxide generated by the enzymatic reaction was detected in an electrochemical flow cell localized outside of the reactor using a platinum disk as the working electrode. The proposed system was applied to the differential amperometric determination of glucose content in soft drinks showing good repeatability (DPR=1.72%, n=50), low detection limit (1.40×10(-6)molL(-1)), high sampling frequency (calculated as 345 samples h(-1)), and relatively good stability for long-term use. The results were in close agreement with those obtained by the classical spectrophotometric method utilized to quantify glucose in biological fluids. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Directional learning and the provisioning of public goods

    PubMed Central

    Nax, Heinrich H.; Perc, Matjaž

    2015-01-01

    We consider an environment where players are involved in a public goods game and must decide repeatedly whether to make an individual contribution or not. However, players lack strategically relevant information about the game and about the other players in the population. The resulting behavior of players is completely uncoupled from such information, and the individual strategy adjustment dynamics are driven only by reinforcement feedbacks from each player's own past. We show that the resulting “directional learning” is sufficient to explain cooperative deviations away from the Nash equilibrium. We introduce the concept of k–strong equilibria, which nest both the Nash equilibrium and the Aumann-strong equilibrium as two special cases, and we show that, together with the parameters of the learning model, the maximal k–strength of equilibrium determines the stationary distribution. The provisioning of public goods can be secured even under adverse conditions, as long as players are sufficiently responsive to the changes in their own payoffs and adjust their actions accordingly. Substantial levels of public cooperation can thus be explained without arguments involving selflessness or social preferences, solely on the basis of uncoordinated directional (mis)learning. PMID:25619192

  1. 40 CFR 1065.526 - Repeating void modes or test intervals.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... or test intervals in any circumstances that would be inconsistent with good engineering judgment. For... that include hybrid energy storage features or emission controls that involve physical or chemical... shut down, restart the engine. (2) Use good engineering judgment to restart the test sequence using the...

  2. 40 CFR 1065.526 - Repeating of void modes or test intervals.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... or test intervals in any circumstances that would be inconsistent with good engineering judgment. For... that include hybrid energy storage features or emission controls that involve physical or chemical... follows: (1) If the engine has stalled or been shut down, restart the engine. (2) Use good engineering...

  3. 40 CFR 1065.526 - Repeating void modes or test intervals.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... or test intervals in any circumstances that would be inconsistent with good engineering judgment. For... that include hybrid energy storage features or emission controls that involve physical or chemical... shut down, restart the engine. (2) Use good engineering judgment to restart the test sequence using the...

  4. Measurement of elasticity and transepidermal water loss rate of burn scars with the Dermalab(®).

    PubMed

    Anthonissen, Mieke; Daly, Daniel; Fieuws, Steffen; Massagé, Patrick; Van Brussel, Michel; Vranckx, Jan; Van den Kerckhove, Eric

    2013-05-01

    This cross-sectional study investigated the reproducibility of repeated elasticity and transepidermal water loss (TEWL) measurements with the DermaLab(®) on 32 active burn scars and healthy skin. Intra- and inter-observer reproducibility was examined by means of intra-class correlation coefficients (ICC) and standard error of measurements (SEM). Results showed good ICC values and rather high SEM values for inter- and intra-observer reproducibility of elasticity measurements. For TEWL measurements, ICC values were good and SEM values were high for inter- and intra-observer reproducibility. There was a significant difference between the estimated mean elasticity values of normal skin and grafted scars and between normal skin and spontaneously healed scars (p≤0.003). For the estimated mean TEWL values, there was a significant difference between normal skin and spontaneously healed scars (p=0.036). A significant negative relation was reported between mean TEWL and time after burn (p=0.008). In clinical trials it is necessary to interpret patient-specific changes in elasticity and TEWL with caution, since the SEMs of both modes are rather high. We therefore recommend the use of a mean of repeated measurements of elasticity and TEWL to decrease the SEM. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.

  5. Screening of Cognitive Impairment in Schizophrenia: Reliability, Sensitivity, and Specificity of the Repeatable Battery for the Assessment of Neuropsychological Status in a Spanish Sample.

    PubMed

    De la Torre, Gabriel G; Perez, Maria J; Ramallo, Miguel A; Randolph, Christopher; González-Villegas, Macarena Bernal

    2016-04-01

    In recent years, a number of studies focusing on the evaluation of neuropsychological deficits in individuals with schizophrenia have shown deficits that include several cognitive functions. Attention deficits as well as memory or executive function deficits are common in this kind of disorder together with sustained attention problems, working memory deficiencies, and problem-solving difficulties, among many others. Currently, the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) is gaining special importance in the evaluation of the cognitive deficits associated with schizophrenia. In this article, we describe an RBANS screening in a sample of 88 Spanish patients diagnosed with schizophrenia. We also aimed to check the battery's reliability, sensitivity, and specificity in the studied sample. We performed a comparative study with 88 healthy participants. The results showed a reliability index value of α = .795 and an item value of α = .762. For total test reliability, we obtained an index value of α = .761 and an item value of α = .762. Sensitivity score was 87.5% and specificity 86.4%. RBANS obtained good reliability, sensitivity, and specificity scores and represents a good screening tool in detecting cognitive deficits associated with schizophrenia. © The Author(s) 2015.

  6. New Yellow Synergist for Stable Pigment Dispersion of Inkjet Ink.

    PubMed

    Song, Gihyun; Lee, Hayoon; Jung, Hyocheol; Kang, Seokwoo; Park, Jongwook

    2018-02-01

    Minimizing ink droplet and self-dispersed pigment mixture are becoming hot issues for high resolution of inkjet printing. New synergist including sulfonic acid group of PY-74 was suggested and synthesized. Pigment itself did not show water solubility but new synergist, SY-11 exhibited good solubility in water and organic solvents such as DMSO and DMF. When aqueous pigment ink was prepared with SY-11, storage stability of the ink has been remained for 7 days under periodically repeated heating and cooling conditions. Particle size of formulated ink was around 150 nm.

  7. Fiber optic humidity sensor based on the graphene oxide/PVA composite film

    NASA Astrophysics Data System (ADS)

    Wang, Youqing; Shen, Changyu; Lou, Weimin; Shentu, Fengying

    2016-08-01

    Fiber optic humidity sensor based on an in-fiber Mach-Zehnder interferometer (MZI) coated with graphene oxide (GO)/PVA composite film was investigated. The MZI is constructed of two waist-enlarged tapers. The length between two waist-enlarged tapers is 20 mm. By comparing the experiment results of MZI coated with different GO/PVA composite films, composite film formed by the ratio of 0.3 g PVA mixed with 10 ml GO dispersion shows a better performance of relative humidity sensing. By using the molecular structure model of the composited GO/PVA, the operation mechanism between GO/PVA composite film and water molecules was illustrated. The sensitivity of 0.193 dB/%RH with a linear correlation coefficient of 99.1% and good stability under the relative humidity range of 25-80% was obtained. Temperature effect on the proposed fiber optic humidity sensor was also considered and analyzed. According to the repetitive experimental results, the proposed humidity sensor shows a good repeatability.

  8. Ultra high performance liquid chromatography with ion-trap TOF-MS for the fast characterization of flavonoids in Citrus bergamia juice.

    PubMed

    Sommella, Eduardo; Pepe, Giacomo; Pagano, Francesco; Tenore, Gian Carlo; Dugo, Paola; Manfra, Michele; Campiglia, Pietro

    2013-10-01

    We have developed a fast ultra HPLC with ion-trap TOF-MS method for the analysis of flavonoids in Citrus bergamia juice. With respect to the typical methods for the analysis of these matrices based on conventional HPLC techniques, a tenfold faster separation was attained. The use of a core-shell particle column ensured high resolution within the fast analysis time of only 5 min. Unambiguous determination of flavonoid identity was obtained by the employment of a hybrid ion-trap TOF mass spectrometer with high mass accuracy (average error 1.69 ppm). The system showed good retention time and peak area repeatability, with maximum RSD% values of 0.36 and 3.86, respectively, as well as good linearity (R(2) ≥ 0.99). Our results show that ultra HPLC can be a useful tool for ultra fast qualitative/quantitative analysis of flavonoid compounds in citrus fruit juices. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. ZnO Nanorods Based Enzymatic Biosensor for Selective Determination of Penicillin

    PubMed Central

    Ibupoto, Zafar Hussain; Ali, Syed Muhammad Usman; Khun, Kimleang; Chey, Chan Oeurn; Nur, Omer; Willander, Magnus

    2011-01-01

    In this study, we have successfully demonstrated the fabrication of a biosensor based on well aligned single-crystal zinc oxide (ZnO) nanorods which were grown on gold coated glass substrate using a low temperature aqueous chemical growth (ACG) method. The ZnO nanorods were immobilized with penicillinase enzyme using the physical adsorption approach in combination with N-5-azido-2-nitrobenzoyloxysuccinimide (ANB-NOS) as cross linking molecules. The potentiometric response of the sensor configuration revealed good linearity over a large logarithmic concentration range from 100 µM to 100 mM. During the investigations, the proposed sensor showed a good stability with high sensitivity of ~121 mV/decade for sensing of penicillin. A quick electrochemical response of less than 5 s with a good selectivity, repeatability, reproducibility and a negligible response to common interferents such as Na1+, K1+, d-glucose, l-glucose, ascorbic acid, uric acid, urea, sucrose, lactose, glycine, penicilloic acid and cephalosporins, was observed. PMID:25585565

  10. ZnO Nanorods Based Enzymatic Biosensor for Selective Determination of Penicillin.

    PubMed

    Ibupoto, Zafar Hussain; Ali, Syed Muhammad Usman; Khun, Kimleang; Chey, Chan Oeurn; Nur, Omer; Willander, Magnus

    2011-10-27

    In this study, we have successfully demonstrated the fabrication of a biosensor based on well aligned single-crystal zinc oxide (ZnO) nanorods which were grown on gold coated glass substrate using a low temperature aqueous chemical growth (ACG) method. The ZnO nanorods were immobilized with penicillinase enzyme using the physical adsorption approach in combination with N-5-azido-2-nitrobenzoyloxysuccinimide (ANB-NOS) as cross linking molecules. The potentiometric response of the sensor configuration revealed good linearity over a large logarithmic concentration range from 100 µM to 100 mM. During the investigations, the proposed sensor showed a good stability with high sensitivity of ~121 mV/decade for sensing of penicillin. A quick electrochemical response of less than 5 s with a good selectivity, repeatability, reproducibility and a negligible response to common interferents such as Na1+, K1+, d-glucose, l-glucose, ascorbic acid, uric acid, urea, sucrose, lactose, glycine, penicilloic acid and cephalosporins, was observed.

  11. Adaptation and validation of a commercial head phantom for cranial radiosurgery dosimetry end-to-end audit.

    PubMed

    Dimitriadis, Alexis; Palmer, Antony L; Thomas, Russell A S; Nisbet, Andrew; Clark, Catharine H

    2017-06-01

    To adapt and validate an anthropomorphic head phantom for use in a cranial radiosurgery audit. Two bespoke inserts were produced for the phantom: one for providing the target and organ at risk for delineation and the other for performing dose measurements. The inserts were tested to assess their positional accuracy. A basic treatment plan dose verification with an ionization chamber was performed to establish a baseline accuracy for the phantom and beam model. The phantom and inserts were then used to perform dose verification measurements of a radiosurgery plan. The dose was measured with alanine pellets, EBT extended dose film and a plastic scintillation detector (PSD). Both inserts showed reproducible positioning (±0.5 mm) and good positional agreement between them (±0.6 mm). The basic treatment plan measurements showed agreement to the treatment planning system (TPS) within 0.5%. Repeated film measurements showed consistent gamma passing rates with good agreement to the TPS. For 2%-2 mm global gamma, the mean passing rate was 96.7% and the variation in passing rates did not exceed 2.1%. The alanine pellets and PSD showed good agreement with the TPS (-0.1% and 0.3% dose difference in the target) and good agreement with each other (within 1%). The adaptations to the phantom showed acceptable accuracies. The presence of alanine and PSD do not affect film measurements significantly, enabling simultaneous measurements by all three detectors. Advances in knowledge: A novel method for thorough end-to-end test of radiosurgery, with capability to incorporate all steps of the clinical pathway in a time-efficient and reproducible manner, suitable for a national audit.

  12. Application of graphene oxide-poly (vinyl alcohol) polymer nanocomposite for memory devices

    NASA Astrophysics Data System (ADS)

    Kaushal, Jyoti; Kaur, Ravneet; Sharma, Jadab; Tripathi, S. K.

    2018-05-01

    Significant attention has been gained by polymer nanocomposites because of their possible demands in future electronic memory devices. In the present work, device based on Graphene Oxide (GO) and polyvinyl alcohol (PVA) has been made and examined for the memory device application. The prepared Graphene oxide (GO) and GO-PVA nanocomposite (NC) has been characterized by X-ray Diffraction (XRD). GO nanosheets show the diffraction peak at 2θ = 11.60° and the interlayer spacing of 0.761 nm. The XRD of GO-PVA NC shows the diffraction peak at 2θ =18.56°. The fabricated device shows bipolar switching behavior having ON/OFF current ratio ˜102. The Write-Read-Erase-Read (WRER) cycles test shows that the Al/GO-PVA/Ag device has good stability and repeatability.

  13. Evolution of All-or-None Strategies in Repeated Public Goods Dilemmas

    PubMed Central

    2014-01-01

    Many problems of cooperation involve repeated interactions among the same groups of individuals. When collective action is at stake, groups often engage in Public Goods Games (PGG), where individuals contribute (or not) to a common pool, subsequently sharing the resources. Such scenarios of repeated group interactions materialize situations in which direct reciprocation to groups may be at work. Here we study direct group reciprocity considering the complete set of reactive strategies, where individuals behave conditionally on what they observed in the previous round. We study both analytically and by computer simulations the evolutionary dynamics encompassing this extensive strategy space, witnessing the emergence of a surprisingly simple strategy that we call All-Or-None (AoN). AoN consists in cooperating only after a round of unanimous group behavior (cooperation or defection), and proves robust in the presence of errors, thus fostering cooperation in a wide range of group sizes. The principles encapsulated in this strategy share a level of complexity reminiscent of that found already in 2-person games under direct and indirect reciprocity, reducing, in fact, to the well-known Win-Stay-Lose-Shift strategy in the limit of the repeated 2-person Prisoner's Dilemma. PMID:25393661

  14. Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe

    PubMed Central

    Dresler, Maria Magdalena; Kociszewski, Jacek; Pędraszewski, Piotr; Trzeciak, Agnieszka; Surkont, Grzegorz

    2017-01-01

    Introduction Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes. PMID:28856017

  15. Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Using 82Rb-PET: Comparison with 13N-Ammonia

    PubMed Central

    Fakhri, Georges El

    2011-01-01

    82Rb cardiac PET allows the assessment of myocardial perfusion using a column generator in clinics that lack a cyclotron. We and others have previously shown that quantitation of myocardial blood flow (MBF) and coronary flow reserve (CFR) is feasible using dynamic 82Rb PET and factor and compartment analyses. The aim of the present work was to determine the intra- and inter-observer variability of MBF estimation using 82Rb PET as well as the reproducibility of our generalized factor + compartment analyses methodology to estimate MBF and assess its accuracy by comparing, in the same subjects, 82Rb estimates of MBF to those obtained using 13N-ammonia. Methods Twenty-two subjects were included in the reproducibility and twenty subjects in the validation study. Patients were injected with 60±5mCi of 82Rb and imaged dynamically for 6 minutes at rest and during dipyridamole stress Left and right ventricular (LV+RV) time-activity curves were estimated by GFADS and used as input to a 2-compartment kinetic analysis that estimates parametric maps of myocardial tissue extraction (K1) and egress (k2), as well as LV+RV contributions (fv,rv). Results Our results show excellent reproducibility of the quantitative dynamic approach itself with coefficients of repeatability of 1.7% for estimation of MBF at rest, 1.4% for MBF at peak stress and 2.8% for CFR estimation. The inter-observer reproducibility between the four observers that participated in this study was also very good with correlation coefficients greater than 0.87 between any two given observers when estimating coronary flow reserve. The reproducibility of MBF in repeated 82Rb studies was good at rest and excellent at peak stress (r2=0.835). Furthermore, the slope of the correlation line was very close to 1 when estimating stress MBF and CFR in repeated 82Rb studies. The correlation between myocardial flow estimates obtained at rest and during peak stress in 82Rb and 13N-ammonia studies was very good at rest (r2=0.843) and stress (r2=0.761). The Bland-Altman plots show no significant presence of proportional error at rest or stress, nor a dependence of the variations on the amplitude of the myocardial blood flow at rest or stress. A small systematic overestimation of 13N-ammonia MBF was observed with 82Rb at rest (0.129 ml/g/min) and the opposite, i.e., underestimation, at stress (0.22 ml/g/min). Conclusions Our results show that absolute quantitation of myocardial bloof flow is reproducible and accurate with 82Rb dynamic cardiac PET as compared to 13N-ammonia. The reproducibility of the quantitation approach itself was very good as well as inter-observer reproducibility. PMID:19525467

  16. [Results from ten years newborn hearing screening in a secondary hospital].

    PubMed

    Sequi Canet, José Miguel; Sala Langa, Maria José; Collar Del Castillo, José Ignacio

    2016-10-01

    A critical analysis is performed on the results of a newborn hearing screening program in a regional hospital. Screening results from 14,247 newborns in our maternity ward from 2002 to 2013. Two step recordings of bilateral otoacoustic emissions (initial and repeat, if failed, at about one month of life). Assessment by clinical brainstem responses. The first step was performed on 14,015 newborns (98.3% of the total) reaching the screening objective. The first step pass figures were 93.7%, which implies a good pass rate with a few patients to repeat. The second step is also good because it has a pass rate of 88.9% of newborns examined (only 0.63% of initial group needed brainstem responses assessment), but 10.6% were lost to follow up, and that is a major problem. In newborns, scheduled for brainstem responses, the loss to follow-up is worse, with a figure of 29.5%, despite the high accuracy of this test given that 69.4% of those assessed showed hearing loss. This figure represents a 0.31% of the initial group, and is a similar to that published for congenital hearing loss. Including patients that were lost to follow up this figure could be greater. Newborn hearing screening is useful but needs stronger control to avoid the follow up loss. In order to achieve this, it is crucial to have a good database and a screening coordinator. Copyright © 2015 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Ensuring the reliability of stable isotope ratio data--beyond the principle of identical treatment.

    PubMed

    Carter, J F; Fry, B

    2013-03-01

    The need for inter-laboratory comparability is crucial to facilitate the globalisation of scientific networks and the development of international databases to support scientific and criminal investigations. This article considers what lessons can be learned from a series of inter-laboratory comparison exercises organised by the Forensic Isotope Ratio Mass Spectrometry (FIRMS) network in terms of reference materials (RMs), the management of data quality, and technical limitations. The results showed that within-laboratory precision (repeatability) was generally good but between-laboratory accuracy (reproducibility) called for improvements. This review considers how stable isotope laboratories can establish a system of quality control (QC) and quality assurance (QA), emphasising issues of repeatability and reproducibility. For results to be comparable between laboratories, measurements must be traceable to the international δ-scales and, because isotope ratio measurements are reported relative to standards, a key aspect is the correct selection, calibration, and use of international and in-house RMs. The authors identify four principles which promote good laboratory practice. The principle of identical treatment by which samples and RMs are processed in an identical manner and which incorporates three further principles; the principle of identical correction (by which necessary corrections are identified and evenly applied), the principle of identical scaling (by which data are shifted and stretched to the international δ-scales), and the principle of error detection by which QC and QA results are monitored and acted upon. To achieve both good repeatability and good reproducibility it is essential to obtain RMs with internationally agreed δ-values. These RMs will act as the basis for QC and can be used to calibrate further in-house QC RMs tailored to the activities of specific laboratories. In-house QA standards must also be developed to ensure that QC-based calibrations and corrections lead to accurate results for samples. The δ-values assigned to RMs must be recorded and reported with all data. Reference materials must be used to determine what corrections are necessary for measured data. Each analytical sequence of samples must include both QC and QA materials which are subject to identical treatment during measurement and data processing. Results for these materials must be plotted, monitored, and acted upon. Periodically international RMs should be analysed as an in-house proficiency test to demonstrate results are accurate.

  18. The incidence of anticipatory nausea and vomiting after repeat cycle chemotherapy: the effect of granisetron.

    PubMed Central

    Aapro, M. S.; Kirchner, V.; Terrey, J. P.

    1994-01-01

    Anticipatory nausea and vomiting (ANV) after repeated cycles of cytotoxic chemotherapy is thought to be a conditioned response to a conditioning stimulus. Good control of acute and delayed emesis may result in a lower incidence of ANV. We have analysed data from 574 chemotherapy patients who received granisetron as their antiemetic treatment during repeat cycle chemotherapy. Per treatment cycle, less than 10% of patients displayed symptoms of anticipatory nausea and 2% or less had symptoms of anticipatory vomiting. It is concluded that the use of granisetron as an antiemetic during the acute phase of chemotherapy may result in a lower incidence of ANV in patients undergoing repeat cycle chemotherapy. PMID:8180031

  19. Reliability of Pentacam HR Thickness Maps of the Entire Cornea in Normal, Post-Laser In Situ Keratomileusis, and Keratoconus Eyes.

    PubMed

    Xu, Zhe; Peng, Mei; Jiang, Jun; Yang, Chun; Zhu, Weigen; Lu, Fan; Shen, Meixiao

    2016-02-01

    To measure the repeatability and reproducibility of Pentacam HR system thickness maps for the entire cornea in normal, post-laser in situ keratomileusis (post-LASIK), and keratoconus (KC) eyes. Reliability study. Sixty normal subjects (60 eyes), 30 post-LASIK subjects (60 eyes), and 14 KC patients (27 eyes) were imaged with the Pentacam HR system by 2 well-trained operators. For pachymetry the cornea was divided into 4 zones: a central zone (2-mm diameter) and concentric pericentral zone (2-5 mm), transitional zone (5-7 mm), and peripheral zone (7-10 mm). The 3 concentric zones were subdivided into 8 sectors. Intraobserver repeatability and interobserver reproducibility of entire corneal thickness maps were tested by the repeatability and reproducibility coefficients, intraclass correlation coefficients, coefficient of variation, and 95% limits of agreement. From central to peripheral zones, the precision of corneal thickness measurements became gradually smaller. Central zone repeatability and reproducibility were the best in the normal, post-LASIK, and KC groups. The peripheral superior sectors showed poorer repeatability and reproducibility for all subjects. The intraobserver repeatability and interobserver reproducibility for all zones were ≤19.3 μm, ≤22.1 μm, and ≤20.7 μm, in the normal, post-LASIK, and KC groups, respectively. The intraobserver and interobserver coefficients of variation for all zones were ≤1.3%, ≤1.6%, and ≤1.6% for all 3 groups. Pentacam HR system pachymetry of the entire cornea provided good precision in normal, post-LASIK, and KC corneas. Thickness measurements in the peripheral cornea should be interpreted with caution in abnormal corneas after surgery or with diseases. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Use of repeat anterior maxillary distraction to correct residual midface hypoplasia in cleft patients.

    PubMed

    Richardson, Sunil; Krishna, Shreya; Bansal, Avi

    2017-12-01

    The study was designed to evaluate the efficacy of performing a second, repeat anterior maxillary distraction (AMD) to treat residual cleft maxillary hypoplasia. Five patients between the ages of 12 to 15 years with a history of AMD and with residual cleft maxillary hypoplasia were included in the study. Inclusion was irrespective of gender, type of cleft lip and palate, and the amount of advancement needed. Repeat AMD was executed in these patients 4 to 5 years after the primary AMD procedure to correct the cleft maxillary hypoplasia that had developed since the initial procedure. Orthopantomogram (OPG) and lateral cephalograms were taken for evaluation preoperatively, immediately after distraction, after consolidation, and one year postoperatively. The data obtained was tabulated and a Mann Whitney U-test was used for statistical comparisons. At the time of presentation, a residual maxillary hypoplasia was observed with a well maintained distraction gap on the OPG which ruled out the occurrence of a relapse. Favorable movement of the segments without any resistance was seen in all patients. Mean maxillary advancement of 10.56 mm was achieved at repeat AMD. Statistically significant increases in midfacial length, SNA angle, and nasion perpendicular to point A distance was achieved ( P =0.012, P =0.011, and P =0.012, respectively). Good profile was achieved for all patients. Minimal transient complications, for example anterior open bite and bleeding episodes, were managed. Addressing the problem of cleft maxillary hypoplasia at an early age (12-15 years) is beneficial for the child. Residual hypoplasia may develop in some patients, which may require additional corrective procedures. The results of our study show that AMD can be repeated when residual deformity develops with the previous procedure having no negative impact on the results of the repeat procedure.

  1. Competitive Bidding in a Certain Class of Auctions

    NASA Astrophysics Data System (ADS)

    Johansson, Mathias

    2006-11-01

    We consider the problem of determining the amount to bid in a certain type of auctions in which customers submit one sealed bid. The bid reflects the price a customer is willing to pay for one unit of the offered goods. The auction is repeated and at each auction each customer requests a certain amount of goods, an amount that we call the capacity of the customer and that varies among customers and over time. At each auction, only the customer with the largest bid-capacity product obtains any goods. The price paid by the winner equals his/her bid-capacity product, and the amount of goods obtained in return equals the winner's capacity. The auction is repeated many times, with only limited information concerning winning bid-capacity products being announced to the customers. This situation is motivated in for example wireless communication networks in which a possible way of obtaining a desired service level is to use dynamic pricing and competitive bidding. In this application, the capacity is typically uncertain when the bid is made. We derive bidding rules and loss functions for a few typical service requirements.

  2. A Palladium-Tin Modified Microband Electrode Array for Nitrate Determination

    PubMed Central

    Fu, Yexiang; Bian, Chao; Kuang, Jian; Wang, Jinfen; Tong, Jianhua; Xia, Shanhong

    2015-01-01

    A microband electrode array modified with palladium-tin bimetallic composite has been developed for nitrate determination. The microband electrode array was fabricated by Micro Electro-Mechanical System (MEMS) technique. Palladium and tin were electrodeposited successively on the electrode, forming a double-layer structure. The effect of the Pd-Sn composite was investigated and its enhancement of catalytic activity and lifetime was revealed. The Pd-Sn modified electrode showed good linearity (R2 = 0.998) from 1 mg/L to 20 mg/L for nitrate determination with a sensitivity of 398 μA/(mg∙L−1∙cm2). The electrode exhibited a satisfying analytical performance after 60 days of storage, indicating a long lifetime. Good repeatability was also displayed by the Pd-Sn modified electrodes. The results provided an option for nitrate determination in water. PMID:26389904

  3. The reliability and validity of fatigue measures during multiple-sprint work: an issue revisited.

    PubMed

    Glaister, Mark; Howatson, Glyn; Pattison, John R; McInnes, Gill

    2008-09-01

    The ability to repeatedly produce a high-power output or sprint speed is a key fitness component of most field and court sports. The aim of this study was to evaluate the validity and reliability of eight different approaches to quantify this parameter in tests of multiple-sprint performance. Ten physically active men completed two trials of each of two multiple-sprint running protocols with contrasting recovery periods. Protocol 1 consisted of 12 x 30-m sprints repeated every 35 seconds; protocol 2 consisted of 12 x 30-m sprints repeated every 65 seconds. All testing was performed in an indoor sports facility, and sprint times were recorded using twin-beam photocells. All but one of the formulae showed good construct validity, as evidenced by similar within-protocol fatigue scores. However, the assumptions on which many of the formulae were based, combined with poor or inconsistent test-retest reliability (coefficient of variation range: 0.8-145.7%; intraclass correlation coefficient range: 0.09-0.75), suggested many problems regarding logical validity. In line with previous research, the results support the percentage decrement calculation as the most valid and reliable method of quantifying fatigue in tests of multiple-sprint performance.

  4. Statistical Methodology for the Analysis of Repeated Duration Data in Behavioral Studies.

    PubMed

    Letué, Frédérique; Martinez, Marie-José; Samson, Adeline; Vilain, Anne; Vilain, Coriandre

    2018-03-15

    Repeated duration data are frequently used in behavioral studies. Classical linear or log-linear mixed models are often inadequate to analyze such data, because they usually consist of nonnegative and skew-distributed variables. Therefore, we recommend use of a statistical methodology specific to duration data. We propose a methodology based on Cox mixed models and written under the R language. This semiparametric model is indeed flexible enough to fit duration data. To compare log-linear and Cox mixed models in terms of goodness-of-fit on real data sets, we also provide a procedure based on simulations and quantile-quantile plots. We present two examples from a data set of speech and gesture interactions, which illustrate the limitations of linear and log-linear mixed models, as compared to Cox models. The linear models are not validated on our data, whereas Cox models are. Moreover, in the second example, the Cox model exhibits a significant effect that the linear model does not. We provide methods to select the best-fitting models for repeated duration data and to compare statistical methodologies. In this study, we show that Cox models are best suited to the analysis of our data set.

  5. Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography

    PubMed Central

    Li, Ming; Lu, Fan

    2017-01-01

    Objectives To evaluate the centration and movement of soft contact lenses and to verify the repeatability of two repeated measurements of the lens centration and movement using ultra-long scan depth optical coherence tomography (UL-OCT). Methods A 1-day Acuvue® Define™ lens was tested on both eyes of 10 subjects (5 males and 5 females; mean age, 31.6 years). The centration and blink-induced movement of the contact lens were measured using UL-OCT at 5 min and 30 min after insertion. The measurements were repeated once at each checkpoint. Results Good repeatability was found in the lens centration and movement between the two repeated measurements at either checkpoint. The values of the lens movement were 0.457 ± 0.248 mm and 0.402 ± 0.229 mm at 5 min and decreased to 0.197 ± 0.065 mm and 0.211 ± 0.110 mm at 30 min after insertion for the right and left eyes, respectively (P < 0.05). Conclusions The custom-built UL-OCT presented good repeatability of centration and movement in Define lenses at 5 min and 30 min after insertion. Most of the lenses were centered temporal and inferior to the cornea during the first 30 min wearing period. Compared with 5 min after insertion, the lens was centered better and exhibited less movement at 30 min. PMID:28751981

  6. Multi Directional Repeated Sprint Is a Valid and Reliable Test for Assessment of Junior Handball Players

    PubMed Central

    Daneshfar, Amin; Gahreman, Daniel E.; Koozehchian, Majid S.; Amani Shalamzari, Sadegh; Hassanzadeh Sablouei, Mozhgan; Rosemann, Thomas; Knechtle, Beat; Nikolaidis, Pantelis T.

    2018-01-01

    The aim of the present study was to examine the validity and reliability of a 10 × (6 × 5 m) multi-directional repeated sprint ability test (RSM) in elite young team handball (TH) players. Participants were members of the Iranian national team (n = 20, age 16.4 ± 0.7 years, weight 82.5 ± 5.5 kg, height 184.8 ± 4.6 cm, body fat 15.4 ± 4.3%). The validity of RSM was tested against a 10 × (15 + 15 m) repeated sprint ability test (RSA), Yo-Yo Intermittent Recovery test Level 1 (Yo-Yo IR1), squat jump (SJ) and countermovement jump (CMJ). To test the reliability of RSM, the participants repeated the testing sessions of RSM and RSA 1 week later. Both RSA and RSM tests showed good to excellent reliability of the total time (TT), best time (BT), and weakest time (WT). The results of the correlation analysis showed significant inverse correlations between maximum aerobic capacity and TT in RSA (r = −0.57, p ≤ 0.05) and RSM (r = −0.76, p ≤ 0.01). There was also a significant inverse correlation between maximum aerobic capacity with fatigue index (FI) in RSA test (r = −0.64, p ≤ 0.01) and in RSM test (r = −0.53, p ≤ 0.05). BT, WT, and TT of RSA was largely-to-very largely correlated with BT (r = 0.58, p ≤ 0.01), WT (r = 0.62, p ≤ 0.01), and TT (r = 0.65, p ≤ 0.01) of RSM. BT in RSM was also correlated with FI in RSM (r = 0.88, p ≤ 0.01). In conclusion, based on the findings of the current study, the recently developed RSM test is a valid and reliable test and should be utilized for assessment of repeated sprint ability in handball players. PMID:29670536

  7. Oxygen-weighted Hyperpolarized 3He MR Imaging: A Short-term Reproducibility Study in Human Subjects

    PubMed Central

    Ishii, Masaru; Hamedani, Hooman; Clapp, Justin T.; Kadlecek, Stephen J.; Xin, Yi; Gefter, Warren B.; Rossman, Milton D.

    2015-01-01

    Purpose To determine whether hyperpolarized helium 3 magnetic resonance (MR) imaging to measure alveolar partial pressure of oxygen (Pao2) shows sufficient test-retest repeatability and between-cohort differences to be used as a reliable technique for detection of alterations in gas exchange in asymptomatic smokers. Materials and Methods The protocol was approved by the local institutional review board and was HIPAA compliant. Informed consent was obtained from all subjects. Two sets of MR images were obtained 10 minutes apart in 25 subjects: 10 nonsmokers (five men, five women; mean ± standard deviation age, 50 years ± 6) and 15 smokers (seven women, eight men; mean age, 50 years ± 8). A mixed-effects model was developed to identify the regional repeatability of Pao2 measurements as an intraclass correlation coefficient. Ten smokers were matched with the 10 nonsmokers on the basis of signal-to-noise ratio (SNR). Three separate models were generated: one for nonsmokers, one for the SNR-matched smokers, and one for the five remaining smokers, who were imaged with a significantly higher SNR. Results Short-term back-to-back regional reproducibility was assessed by using intraclass correlation coefficients, which were 0.67 and 0.65 for SNR case-matched nonsmokers and smokers, respectively. Repeatability was a strong function of SNR; a 50% increase in SNR in the remaining smokers improved the intraclass correlation coefficient to 0.82. Although repeatability was not significantly different between the SNR-matched cohorts (P = .44), the smoker group showed higher spatial and temporal variability in Pao2. Conclusion The short-term test-retest repeatability of hyperpolarized gas MR imaging of regional Pao2 was good. Asymptomatic smokers exhibited greater spatial and temporal variability in Pao2 than did the nonsmokers, which suggests that this parameter allows detection of small functional alterations associated with smoking. © RSNA, 2015 Online supplemental material is available for this article. PMID:26110668

  8. Multi Directional Repeated Sprint Is a Valid and Reliable Test for Assessment of Junior Handball Players.

    PubMed

    Daneshfar, Amin; Gahreman, Daniel E; Koozehchian, Majid S; Amani Shalamzari, Sadegh; Hassanzadeh Sablouei, Mozhgan; Rosemann, Thomas; Knechtle, Beat; Nikolaidis, Pantelis T

    2018-01-01

    The aim of the present study was to examine the validity and reliability of a 10 × (6 × 5 m) multi-directional repeated sprint ability test (RSM) in elite young team handball (TH) players. Participants were members of the Iranian national team ( n = 20, age 16.4 ± 0.7 years, weight 82.5 ± 5.5 kg, height 184.8 ± 4.6 cm, body fat 15.4 ± 4.3%). The validity of RSM was tested against a 10 × (15 + 15 m) repeated sprint ability test (RSA), Yo-Yo Intermittent Recovery test Level 1 (Yo-Yo IR1), squat jump (SJ) and countermovement jump (CMJ). To test the reliability of RSM, the participants repeated the testing sessions of RSM and RSA 1 week later. Both RSA and RSM tests showed good to excellent reliability of the total time (TT), best time (BT), and weakest time (WT). The results of the correlation analysis showed significant inverse correlations between maximum aerobic capacity and TT in RSA ( r = -0.57, p ≤ 0.05) and RSM ( r = -0.76, p ≤ 0.01). There was also a significant inverse correlation between maximum aerobic capacity with fatigue index (FI) in RSA test ( r = -0.64, p ≤ 0.01) and in RSM test ( r = -0.53, p ≤ 0.05). BT, WT, and TT of RSA was largely-to-very largely correlated with BT ( r = 0.58, p ≤ 0.01), WT ( r = 0.62, p ≤ 0.01), and TT ( r = 0 .65, p ≤ 0.01) of RSM. BT in RSM was also correlated with FI in RSM ( r = 0.88, p ≤ 0.01). In conclusion, based on the findings of the current study, the recently developed RSM test is a valid and reliable test and should be utilized for assessment of repeated sprint ability in handball players.

  9. The effects of aging on conflict detection.

    PubMed

    Lucci, Giuliana; Berchicci, Marika; Spinelli, Donatella; Taddei, Francesco; Di Russo, Francesco

    2013-01-01

    Several cognitive changes characterize normal aging; one change regards inhibitory processing and includes both conflict monitoring and response suppression. We attempted to segregate these two aspects within a Go/No-go task, investigating three age categories. Accuracy, response times and event-related potentials (ERPs) were recorded. The ERP data were analyzed, and the Go and No-go trials were separated; in addition, the trials were organized in repeat trials (in which the subjects repeated the action delivered in the previous trial) and switch trials (in which the subjects produced a response opposite to the previous response). We assumed that the switch trials conveyed more conflict than the repeat trials. In general, the behavioral data and slower P3 latencies confirmed the well-known age-related speed/accuracy trade-off. The novel analyses of the repeat vs. switch trials indicated that the age-related P3 slowing was significant only for the high conflict condition; the switch-P3 amplitude increased only in the two older groups. The 'aging switch effect' on the P3 component suggests a failure in the conflict conditions and likely contributes to a generalized dysfunction. The absence of either a switch effect in the young group and the P3 slowing in middle-aged group indicate that switching was not particularly demanding for these participants. The N2 component was less sensitive to the repeat/switch manipulation; however, the subtractive waves also enhanced the age effects in this earlier time window. The topographic maps showed other notable age effects: the frontal No-go N2 was nearly undetectable in the elderly; in the identical time window, a large activity in the posterior and prefrontal scalp regions was observed. Moreover, the prefrontal activity showed a negative correlation with false alarms. These results suggest that the frontal involvement during action suppression becomes progressively dysfunctional with aging, and additional activity was required to reach a good level of accuracy.

  10. Identification of Variable-Number Tandem-Repeat (VNTR) Sequences in Acinetobacter baumannii and Interlaboratory Validation of an Optimized Multiple-Locus VNTR Analysis Typing Scheme▿†

    PubMed Central

    Pourcel, Christine; Minandri, Fabrizia; Hauck, Yolande; D'Arezzo, Silvia; Imperi, Francesco; Vergnaud, Gilles; Visca, Paolo

    2011-01-01

    Acinetobacter baumannii is an important opportunistic pathogen responsible for nosocomial outbreaks, mostly occurring in intensive care units. Due to the multiplicity of infection sources, reliable molecular fingerprinting techniques are needed to establish epidemiological correlations among A. baumannii isolates. Multiple-locus variable-number tandem-repeat analysis (MLVA) has proven to be a fast, reliable, and cost-effective typing method for several bacterial species. In this study, an MLVA assay compatible with simple PCR- and agarose gel-based electrophoresis steps as well as with high-throughput automated methods was developed for A. baumannii typing. Preliminarily, 10 potential polymorphic variable-number tandem repeats (VNTRs) were identified upon bioinformatic screening of six annotated genome sequences of A. baumannii. A collection of 7 reference strains plus 18 well-characterized isolates, including unique types and representatives of the three international A. baumannii lineages, was then evaluated in a two-center study aimed at validating the MLVA assay and comparing it with other genotyping assays, namely, macrorestriction analysis with pulsed-field gel electrophoresis (PFGE) and PCR-based sequence group (SG) profiling. The results showed that MLVA can discriminate between isolates with identical PFGE types and SG profiles. A panel of eight VNTR markers was selected, all showing the ability to be amplified and good amounts of polymorphism in the majority of strains. Independently generated MLVA profiles, composed of an ordered string of allele numbers corresponding to the number of repeats at each VNTR locus, were concordant between centers. Typeability, reproducibility, stability, discriminatory power, and epidemiological concordance were excellent. A database containing information and MLVA profiles for several A. baumannii strains is available from http://mlva.u-psud.fr/. PMID:21147956

  11. Zinc oxide crystal whiskers as a novel sorbent for solid-phase extraction of flavonoids.

    PubMed

    Wang, Licheng; Shangguan, Yangnan; Hou, Xiudan; Jia, Yong; Liu, Shujuan; Sun, Yingxin; Guo, Yong

    2017-08-15

    As a novel solid-phase extraction material, zinc oxide crystal whiskers were used to extract flavonoid compounds and showed good extraction abilities. X-ray diffraction, scanning electron microscopy with energy dispersive X-ray spectroscopy and surface area/pore volume characterized the sorbent. The zinc oxide was packed into a solid-phase extraction micro-column and its extraction ability was evaluated by four model flavonoid compounds. The sample loading and elution parameters were optimized and the zinc oxide based analytical method for flavonoids was established. It showed that the method has wide linearities from 1 to 150μg/L and low limits of detection at 0.25μg/L. The relative standard deviations of a single column repeatability and column to column reproducibility were less than 6.8% and 10.6%. Several real samples were analyzed by the established method and satisfactory results were obtained. The interactions between flavonoids and zinc oxide were calculated and proved to be from the Van der Waals' forces between the 4p and 5d orbitals from zinc atom and the neighboring π orbitals from flavonoid phenyl groups. Moreover, the zinc oxide crystal whiskers showed good stability and could be reused more than 50 times under the operation conditions. This work proves that the zinc oxide crystal whiskers are a good candidate for flavonoids enrichment. Copyright © 2017. Published by Elsevier B.V.

  12. Variable flip angle 3D ultrashort echo time (UTE) T1 mapping of mouse lung: A repeatability assessment.

    PubMed

    Alamidi, Daniel F; Smailagic, Amir; Bidar, Abdel W; Parker, Nicole S; Olsson, Marita; Hockings, Paul D; Lagerstrand, Kerstin M; Olsson, Lars E

    2018-03-08

    Lung T 1 is a potential translational biomarker of lung disease. The precision and repeatability of variable flip angle (VFA) T 1 mapping using modern 3D ultrashort echo time (UTE) imaging of the whole lung needs to be established before it can be used to assess response to disease and therapy. To evaluate the feasibility of regional lung T 1 quantification with VFA 3D-UTE and to investigate long- and short-term T 1 repeatability in the lungs of naive mice. Prospective preclinical animal study. Eight naive mice and phantoms. 3D free-breathing radial UTE (8 μs) at 4.7T. VFA 3D-UTE T 1 calculations were validated against T 1 values measured with inversion recovery (IR) in phantoms. Lung T 1 and proton density (S 0 ) measurements of whole lung and muscle were repeated five times over 1 month in free-breathing naive mice. Two consecutive T 1 measurements were performed during one of the imaging sessions. Agreement in T 1 between VFA 3D-UTE and IR in phantoms was assessed using Bland-Altman and Pearson 's correlation analysis. The T 1 repeatability in mice was evaluated using coefficient of variation (CV), repeated-measures analysis of variance (ANOVA), and paired t-test. Good T 1 agreement between the VFA 3D-UTE and IR methods was found in phantoms. T 1 in lung and muscle showed a 5% and 3% CV (1255 ± 63 msec and 1432 ± 42 msec, respectively, mean ± SD) with no changes in T 1 or S 0 over a month. Consecutive measurements resulted in an increase of 2% in both lung T 1 and S 0 . VFA 3D-UTE shows promise as a reliable T 1 mapping method that enables full lung coverage, high signal-to-noise ratio (∼25), and spatial resolution (300 μm) in freely breathing animals. The precision of the VFA 3D-UTE method will enable better design and powering of studies. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  13. Repeatability and oblique flow response characteristics of current meters

    USGS Publications Warehouse

    Fulford, Janice M.; Thibodeaux, Kirk G.; Kaehrle, William R.; ,

    1993-01-01

    Laboratory investigation into the precision and accuracy of various mechanical-current meters are presented. Horizontal-axis and vertical-axis meters that are used for the measurement of point velocities in streams and rivers were tested. Meters were tested for repeatability and response to oblique flows. Both horizontal- and vertical-axis meters were found to under- and over-register oblique flows with errors generally increasing as the velocity and angle of flow increased. For the oblique flow tests, magnitude of errors were smallest for horizontal-axis meters. Repeatability of all meters tested was good, with the horizontal- and vertical-axis meters performing similarly.

  14. Investigation of dimensional variation in parts manufactured by fused deposition modeling using Gauge Repeatability and Reproducibility

    NASA Astrophysics Data System (ADS)

    Mohamed, Omar Ahmed; Hasan Masood, Syed; Lal Bhowmik, Jahar

    2018-02-01

    In the additive manufacturing (AM) market, the question is raised by industry and AM users on how reproducible and repeatable the fused deposition modeling (FDM) process is in providing good dimensional accuracy. This paper aims to investigate and evaluate the repeatability and reproducibility of the FDM process through a systematic approach to answer this frequently asked question. A case study based on the statistical gage repeatability and reproducibility (gage R&R) technique is proposed to investigate the dimensional variations in the printed parts of the FDM process. After running the simulation and analysis of the data, the FDM process capability is evaluated, which would help the industry for better understanding the performance of FDM technology.

  15. Short-Term Repeatability of Noninvasive Aortic Pulse Wave Velocity Assessment: Comparison Between Methods and Devices.

    PubMed

    Grillo, Andrea; Parati, Gianfranco; Rovina, Matteo; Moretti, Francesco; Salvi, Lucia; Gao, Lan; Baldi, Corrado; Sorropago, Giovanni; Faini, Andrea; Millasseau, Sandrine C; Scalise, Filippo; Carretta, Renzo; Salvi, Paolo

    2017-12-08

    Aortic pulse wave velocity (PWV) is an indirect index of arterial stiffness and an independent cardiovascular risk factor. Consistency of PWV assessment over time is thus an essential feature for its clinical application. However, studies providing a comparative estimate of the reproducibility of PWV across different noninvasive devices are lacking, especially in the elderly and in individuals at high cardiovascular risk. Aimed at filling this gap, short-term repeatability of PWV, estimated with 6 different devices (Complior Analyse, PulsePen-ETT, PulsePen-ET, SphygmoCor Px/Vx, BPLab, and Mobil-O-Graph), was evaluated in 102 high cardiovascular risk patients hospitalized for suspected coronary artery disease (72 males, 65 ± 13 years). PWV was measured in a single session twice, at 15-minute interval, and its reproducibility was assessed though coefficient of variation (CV), coefficient of repeatability, and intraclass correlation coefficient. The CV of PWV, measured with any of these devices, was <10%. Repeatability was higher with cuff-based methods (BPLab: CV = 5.5% and Mobil-O-Graph: CV = 3.4%) than with devices measuring carotid-femoral PWV (Complior: CV = 8.2%; PulsePen-TT: CV = 8.0%; PulsePen-ETT: CV = 5.8%; and SphygmoCor: CV = 9.5%). In the latter group, PWV repeatability was lower in subjects with higher carotid-femoral PWV. The differences in PWV between repeated measurements, except for the Mobil-O-Graph, did not depend on short-term variations of mean blood pressure or heart rate. Our study shows that the short-term repeatability of PWV measures is good but not homogenous across different devices and at different PWV values. These findings, obtained in patients at high cardiovascular risk, may be relevant when evaluating the prognostic importance of PWV. © American Journal of Hypertension, Ltd 2017. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  16. Fuel ethanol production from sweet sorghum using repeated-batch fermentation.

    PubMed

    Chohnan, Shigeru; Nakane, Megumi; Rahman, M Habibur; Nitta, Youji; Yoshiura, Takanori; Ohta, Hiroyuki; Kurusu, Yasurou

    2011-04-01

    Ethanol was efficiently produced from three varieties of sweet sorghum using repeated-batch fermentation without pasteurization or acidification. Saccharomyces cerevisiae cells could be recycled in 16 cycles of the fermentation process with good ethanol yields. This technique would make it possible to use a broader range of sweet sorghum varieties for ethanol production. Copyright © 2010 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  17. A parent‐completed respiratory questionnaire for 1‐year‐old children: repeatability

    PubMed Central

    Strippoli, Marie‐Pierre F; Silverman, Michael; Michel, Gisela; Kuehni, Claudia E

    2007-01-01

    Background and aims There are few standardised questionnaires for the assessment of respiratory symptoms in preschool children. We have developed and tested the short‐term repeatability of a postal questionnaire on respiratory symptoms for 1‐year‐old children. Methods A newly developed postal questionnaire for the assessment of wheeze and other respiratory symptoms was sent to parents of a population‐based random sample of 4300 children aged 12–24 months. After an interval of 3 months, a random sample of 800 respondents received the questionnaire a second time. The responses were compared using Cohen's kappa (κ) to assess agreement corrected for chance. Results The first questionnaire was returned by 3194 (74%) families, the second one by 460/800 (58%). Repeatability was excellent (κ 0.80–0.96) for questions on household characteristics, environmental exposures and family history, good (κ 0.61–0.80) for questions on prevalence, severity and treatment of wheeze, and moderate (κ 0.39–0.66) for chronic cough and upper respiratory symptoms. Conclusions This short postal questionnaire designed for use in population‐based studies has excellent repeatability for family and household characteristics and good repeatability for questions on wheeze. Short‐term changes in symptom status might be responsible for variable answers on recent chronic cough and upper respiratory symptoms. Overall, the questionnaire is a valuable instrument for community‐based research on respiratory symptoms in 1 to 2‐year‐old children. PMID:17502330

  18. In situ transmission electron microscopy of individual carbon nanotetrahedron/ribbon structures in bending

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kohno, Hideo, E-mail: kohno.hideo@kochi-tech.ac.jp; Masuda, Yusuke

    2015-05-11

    When the direction of flattening of a carbon nanotube changes during growth mediated by a metal nanoparticle, a carbon nanotetrahedron is formed in the middle of the carbon nanoribbon. We report the bending properties of the carbon nanotetrahedron/nanoribbon structure using a micro-manipulator system in a transmission electron microscope. In many cases, bending occurs at an edge of the carbon nanotetrahedron. No significant change is observed in the tetrahedron's shape during bending, and the bending is reversible and repeatable. Our results show that the carbon nanotetrahedron/nanoribbon structure has good durability against mechanical bending.

  19. High precision optical fiber Fabry-Perot sensor for gas pressure detection

    NASA Astrophysics Data System (ADS)

    Mao, Yan; Tong, Xing-lin

    2013-09-01

    An optical fiber Fabry-Perot (F-P) sensor with quartz diaphragm for gas pressure testing was designed and fabricated. It consisted of single-mode fiber, hollow glass tube and quartz diaphragm. It uses the double peak demodulation to obtain the initialized cavity length. The variety of cavity length can be calcultated by the single peak demodulation after changing the gas pressure. The results show that the sensor is small in size, whose sensitivity is 19 pm/kPa in the range of the 10 ~ 260 kPa gas pressure. And it has good linearity and repeatability.

  20. Retrofit concept for small safety related stationary machines

    NASA Astrophysics Data System (ADS)

    Epple, S.; Jalba, C. K.; Muminovic, A.; Jung, R.

    2017-05-01

    More and more old machines have the problem that their control electronics’ lifecycle comes to its intended end of life, whilst the mechanics itself and process capability is still in very good condition. This article shows an example of a reactive ion etcher originally built in 1988, which was refitted with a new control concept. The original control unit was repaired several times based on manufacturer’s obsolescence management. At start of the retrofit project the integrated circuits were no longer available for further repair of the original control unit. Safety, repeatability and stability of the process were greatly improved.

  1. Improving frequencies range measurement of vibration sensor based on Fiber Bragg Grating (FBG)

    NASA Astrophysics Data System (ADS)

    Qomaruddin; Setiono, A.; Afandi, M. I.

    2017-04-01

    This research aimed to develop a vibration sensor based on Fiber Bragg Grating (FBG). The design was mainly done by attaching FBG at the cantilever. The free-end of the cantilever was tied to a vibration source in order to increase the measurement range of vibration frequencies. The results indicated that the developed sensor was capable of detecting wide range of frequencies (i.e. 10 - 1700 Hz). The results also showed both good stability and repeatability. The measured frequency range was 566 times greater than the range obtained from the previous works.

  2. Serine 192 in the tiny RS repeat of the adenoviral L4-33K splicing enhancer protein is essential for function and reorganization of the protein to the periphery of viral replication centers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oestberg, Sara, E-mail: sara.ostberg@imbim.uu.se; Toermaenen Persson, Heidi, E-mail: heidi.tormanen.persson@imbim.uu.se; Akusjaervi, Goeran, E-mail: goran.akusjarvi@imbim.uu.se

    2012-11-25

    The adenovirus L4-33K protein is a key regulator involved in the temporal shift from early to late pattern of mRNA expression from the adenovirus major late transcription unit. L4-33K is a virus-encoded alternative splicing factor, which enhances processing of 3 Prime splice sites with a weak sequence context. Here we show that L4-33K expressed from a plasmid is localized at the nuclear margin of uninfected cells. During an infection L4-33K is relocalized to the periphery of E2A-72K containing viral replication centers. We also show that serine 192 in the tiny RS repeat of the conserved carboxy-terminus of L4-33K, which ismore » critical for the splicing enhancer function of L4-33K, is necessary for the nuclear localization and redistribution of the protein to viral replication sites. Collectively, our results show a good correlation between the activity of L4-33K as a splicing enhancer protein and its localization to the periphery of viral replication centers.« less

  3. Development of the Internet addiction scale based on the Internet Gaming Disorder criteria suggested in DSM-5.

    PubMed

    Cho, Hyun; Kwon, Min; Choi, Ji-Hye; Lee, Sang-Kyu; Choi, Jung Seok; Choi, Sam-Wook; Kim, Dai-Jin

    2014-09-01

    This study was conducted to develop and validate a standardized self-diagnostic Internet addiction (IA) scale based on the diagnosis criteria for Internet Gaming Disorder (IGD) in the Diagnostic and Statistical Manual of Mental Disorder, 5th edition (DSM-5). Items based on the IGD diagnosis criteria were developed using items of the previous Internet addiction scales. Data were collected from a community sample. The data were divided into two sets, and confirmatory factor analysis (CFA) was performed repeatedly. The model was modified after discussion with professionals based on the first CFA results, after which the second CFA was performed. The internal consistency reliability was generally good. The items that showed significantly low correlation values based on the item-total correlation of each factor were excluded. After the first CFA was performed, some factors and items were excluded. Seven factors and 26 items were prepared for the final model. The second CFA results showed good general factor loading, Squared Multiple Correlation (SMC) and model fit. The model fit of the final model was good, but some factors were very highly correlated. It is recommended that some of the factors be refined through further studies. Copyright © 2014. Published by Elsevier Ltd.

  4. Bilateral cross-bite treated by repeated rapid maxillary expansions: a 17-year follow-up case.

    PubMed

    Cozzani, M; Mazzotta, L; Caprioglio, A

    2014-07-01

    The objective of this paper is to show the clinical results after the repeated application of a Haas expander for rapid maxillary expansion (RME) anchored onto deciduous teeth in a 7-year-old patient that presented bilateral cross-bite, superior crowding and no space for permanent lateral incisors eruption. A first Haas expander was applied to the patient. She was told to activate it once a day, each activation was equal to 0.20 mm. After the first RME, the bilateral cross-bite was solved but still there was not enough space for lateral incisor eruption. A second and then a third Haas expander were applied, with the same activation protocol as the first one, in order to gain space in the anterior region and to achieve proper eruption of the lateral incisors. The patient was then treated with fixed appliances. At debonding the patient presented well aligned arch-forms: space for lateral incisor eruption was gained and superior crowding was solved. Bilateral cross-bite was also corrected. She was seen again 10 years and 17 years after expansions: she showed no relapse and presented a good functional occlusion that had remained stable, and an aesthetically pleasant smile, however she exhibited gingival recessions. Repeated rapid maxillary expansion, anchored onto deciduous teeth, performed in early mixed dentition represents a safe and successful treatment to correct severe bilateral cross- bites and to create space for maxillary incisor eruption.

  5. Intra-dance variation among waggle runs and the design of efficient protocols for honey bee dance decoding.

    PubMed

    Couvillon, Margaret J; Riddell Pearce, Fiona C; Harris-Jones, Elisabeth L; Kuepfer, Amanda M; Mackenzie-Smith, Samantha J; Rozario, Laura A; Schürch, Roger; Ratnieks, Francis L W

    2012-05-15

    Noise is universal in information transfer. In animal communication, this presents a challenge not only for intended signal receivers, but also to biologists studying the system. In honey bees, a forager communicates to nestmates the location of an important resource via the waggle dance. This vibrational signal is composed of repeating units (waggle runs) that are then averaged by nestmates to derive a single vector. Manual dance decoding is a powerful tool for studying bee foraging ecology, although the process is time-consuming: a forager may repeat the waggle run 1- >100 times within a dance. It is impractical to decode all of these to obtain the vector; however, intra-dance waggle runs vary, so it is important to decode enough to obtain a good average. Here we examine the variation among waggle runs made by foraging bees to devise a method of dance decoding. The first and last waggle runs within a dance are significantly more variable than the middle run. There was no trend in variation for the middle waggle runs. We recommend that any four consecutive waggle runs, not including the first and last runs, may be decoded, and we show that this methodology is suitable by demonstrating the goodness-of-fit between the decoded vectors from our subsamples with the vectors from the entire dances.

  6. Intra-dance variation among waggle runs and the design of efficient protocols for honey bee dance decoding

    PubMed Central

    Couvillon, Margaret J.; Riddell Pearce, Fiona C.; Harris-Jones, Elisabeth L.; Kuepfer, Amanda M.; Mackenzie-Smith, Samantha J.; Rozario, Laura A.; Schürch, Roger; Ratnieks, Francis L. W.

    2012-01-01

    Summary Noise is universal in information transfer. In animal communication, this presents a challenge not only for intended signal receivers, but also to biologists studying the system. In honey bees, a forager communicates to nestmates the location of an important resource via the waggle dance. This vibrational signal is composed of repeating units (waggle runs) that are then averaged by nestmates to derive a single vector. Manual dance decoding is a powerful tool for studying bee foraging ecology, although the process is time-consuming: a forager may repeat the waggle run 1- >100 times within a dance. It is impractical to decode all of these to obtain the vector; however, intra-dance waggle runs vary, so it is important to decode enough to obtain a good average. Here we examine the variation among waggle runs made by foraging bees to devise a method of dance decoding. The first and last waggle runs within a dance are significantly more variable than the middle run. There was no trend in variation for the middle waggle runs. We recommend that any four consecutive waggle runs, not including the first and last runs, may be decoded, and we show that this methodology is suitable by demonstrating the goodness-of-fit between the decoded vectors from our subsamples with the vectors from the entire dances. PMID:23213438

  7. Brain pathology after mild traumatic brain injury: an exploratory study by repeated magnetic resonance examination.

    PubMed

    Lannsjö, Marianne; Raininko, Raili; Bustamante, Mariana; von Seth, Charlotta; Borg, Jörgen

    2013-09-01

    To explore brain pathology after mild traumatic brain injury by repeated magnetic resonance examination. A prospective follow-up study. Nineteen patients with mild traumatic brain injury presenting with Glasgow Coma Scale (GCS) 14-15. The patients were examined on day 2 or 3 and 3-7 months after the injury. The magnetic resonance protocol comprised conventional T1- and T2-weighted sequences including fluid attenuated inversion recovery (FLAIR), two susceptibility-weighted sequences to reveal haemorrhages, and diffusion-weighted sequences. Computer-aided volume comparison was performed. Clinical outcome was assessed by the Rivermead Post-Concussion Symptoms Questionnaire (RPQ), Hospital Anxiety and Depression Scale (HADS) and Glasgow Outcome Scale Extended (GOSE). At follow-up, 7 patients (37%) reported ≥  3 symptoms in RPQ, 5 reported some anxiety and 1 reported mild depression. Fifteen patients reported upper level of good recovery and 4 patients lower level of good recovery (GOSE 8 and 7, respectively). Magnetic resonance pathology was found in 1 patient at the first examination, but 4 patients (21%) showed volume loss at the second examination, at which 3 of them reported < 3 symptoms and 1 ≥ 3 symptoms, all exhibiting GOSE scores of 8. Loss of brain volume, demonstrated by computer-aided magnetic resonance imaging volumetry, may be a feasible marker of brain pathology after mild traumatic brain injury.

  8. Unresolved Galaxy Classifier for ESA/Gaia mission: Support Vector Machines approach

    NASA Astrophysics Data System (ADS)

    Bellas-Velidis, Ioannis; Kontizas, Mary; Dapergolas, Anastasios; Livanou, Evdokia; Kontizas, Evangelos; Karampelas, Antonios

    A software package Unresolved Galaxy Classifier (UGC) is being developed for the ground-based pipeline of ESA's Gaia mission. It aims to provide an automated taxonomic classification and specific parameters estimation analyzing Gaia BP/RP instrument low-dispersion spectra of unresolved galaxies. The UGC algorithm is based on a supervised learning technique, the Support Vector Machines (SVM). The software is implemented in Java as two separate modules. An offline learning module provides functions for SVM-models training. Once trained, the set of models can be repeatedly applied to unknown galaxy spectra by the pipeline's application module. A library of galaxy models synthetic spectra, simulated for the BP/RP instrument, is used to train and test the modules. Science tests show a very good classification performance of UGC and relatively good regression performance, except for some of the parameters. Possible approaches to improve the performance are discussed.

  9. CHARACTERISTICS OF THERMOLUMINESCENCE LiF:Mg,Cu,Ag NANOPHOSPHOR.

    PubMed

    Yahyaabadi, A; Torkzadeh, F; Rezaei-Ochbelagh, D

    2018-04-23

    A nanophosphor of LiF:Mg,Cu,Ag was prepared by planetary ball milling for the first time in the laboratory. The size and shape of the nanophosphor were confirmed by XRD and SEM, which showed that it was cubic in shape and ~53 nm in size. The thermoluminescence (TL) characteristics of this nanophosphor were then investigated. It was found that the optimum annealing condition was 250°C for 10 min. The TL sensitivity of the prepared nanopowder was less than that of its micropowder counterpart and the TL glow curve structure exhibited several peaks. The LiF:Mg,Cu,Ag nanophosphor exhibited a linear response over a range of doses from 1 Gy to ~10 kGy. From this study, it appears that LiF:Mg,Cu,Ag nanophosphor is a good candidate for dosimetry because of its linearity over a range of doses, low tendency to fade, good repeatability and simple glow curve structure.

  10. Selectivity of hexaphenylbenzene-based hydrocarbon stationary phase with propeller-like conformation for aromatic and aliphatic isomers.

    PubMed

    Yang, Yinhui; Chang, Zhengfeng; Yang, Xiaohong; Qi, Meiling; Wang, Jinliang

    2018-08-03

    Herein we report a propeller-like hexaphenylbenzene-based hydrocarbon material (denoted as BT) as the stationary phase for capillary gas chromatography (GC). The statically-coated BT capillary column showed a high column efficiency of 4340 plates m -1 and weak polarity. Owing to its unique conformation, π-electron toroidal delocalization and intrinsic microporosity, the BT stationary phase exhibited interesting selectivity for aromatic compounds over alkanes. Compared with the graphene (G) column, the BT column showed much prolonged retention and high selectivity for aromatic isomers, especially methylnaphthalenes, dimethylnaphthalenes and phenanthrene/anthracene, mainly because of its propeller-like conformation with rich intercalation effects. Moreover, it exhibited good column repeatability (intra-day, inter-day) and reproducibility (between-column) with RSD values on the retention times less than 0.08% for intra-day, 0.32% for inter-day and 3.8% for between-column, respectively. Also, it showed good potential for determination of minor isomer impurities in real samples. To the best of our knowledge, this work presents the first example of employing an neat aromatic hydrocarbon material as the GC stationary phase with high selectivity for analytes of a wide ranging polarity. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Humidity detection using chitosan film based sensor

    NASA Astrophysics Data System (ADS)

    Nasution, T. I.; Nainggolan, I.; Dalimunthe, D.; Balyan, M.; Cuana, R.; Khanifah, S.

    2018-02-01

    A humidity sensor made of the natural polymer chitosan has been successfully fabricated in the film form by a solution casting method. Humidity testing was performed by placing a chitosan film sensor in a cooling machine room, model KT-2000 Ahu. The testing results showed that the output voltage values of chitosan film sensor increased with the increase in humidity percentage. For the increase in humidity percentage from 30 to 90% showed that the output voltage of chitosan film sensor increased from 32.19 to 138.75 mV. It was also found that the sensor evidenced good repeatability and stability during the testing. Therefore, chitosan has a great potential to be used as new sensing material for the humidity detection of which was cheaper and environmentally friendly.

  12. Magnetic field sensing based on tilted fiber Bragg grating coated with nanoparticle magnetic fluid

    NASA Astrophysics Data System (ADS)

    Yang, Dexing; Du, Lei; Xu, Zengqi; Jiang, Yajun; Xu, Jian; Wang, Meirong; Bai, Yang; Wang, Haiyan

    2014-02-01

    A magnetic field sensor based on a tilted fiber Bragg grating (TFBG) coated with magnetic fluid is proposed and demonstrated experimentally. The sensing element is made by injecting the magnetic fluid into a capillary tube which contains a TFBG. The resonant wavelengths of the cladding modes of TFBG shift by varying the magnetic field which is perpendicular to the axis of TFBG. The results indicate that the resonant wavelength shifts of the cladding modes show a nonlinear dependence on the magnetic field. As the magnetic field increases to 32 mT, the largest resonant wavelength shift reaches to 106 pm. Moreover, this sensor shows good repeatability when it is used for magnetic field sensing.

  13. Thin-film-based optical fiber Fabry-Perot interferometer used for humidity sensing.

    PubMed

    Peng, Jiankun; Qu, Yapeng; Wang, Weijia; Sun, Tengpeng; Yang, Minghong

    2018-04-20

    A thin-film-based optical fiber Fabry-Perot interferometer that consists of ZrO 2 and SiO 2 porous thin films is designed and fabricated by electron beam physical vapor deposition. Since the SiO 2 porous thin film has the capability of water adsorption, the proposed Fabry-Perot interferometer is appropriate to detect humidity. Experimental results show that the prepared sensor has a humidity detection range from 0.06% RH to 70% RH. A cycling test shows that the humidity sensor has a responding or recover time of 4 s and good repeatability among different humidity environments. Especially, the proposed humidity sensor is insensitive to temperature variation and suitable for the detection of low relative humidity.

  14. Railgun armature velocity improvement, SBIR phase 2

    NASA Astrophysics Data System (ADS)

    Thurmond, Leo E.; Bauer, David P.

    1992-08-01

    Railgun hypervelocity performance has not been repeatably demonstrated at velocities over 6 km/s. A significant performance limiting phenomena is the formation of secondary current paths in parallel with the main projectile accelerating plasma. A confined plasma armature technique was developed to prevent secondary armature formation. Confinement prevents loss of ionized material from the plasma armature and thereby prevents formation of a low rail-to-rail conductance. We controlled pressure in the confined armature via controlled venting through ports in the rails. Railgun tests with the confined armature show that sealing at the rail-confinement vessel interface is critical and difficult to achieve. Our tests show that during low seal leakage operation secondaries are prevented. However, maintaining good seal for the entire launch is very difficult.

  15. Effects of the enlargement of poly-glutamine segments on the structure and folding of ataxin-2 and ataxin-3 proteins

    PubMed Central

    Wen, Jingran; Scoles, Daniel R.; Facelli, Julio C.

    2017-01-01

    Spinocerebellar ataxia type 2 (SCA2) and type 3 (SCA3) are two common autosomal-dominant inherited ataxia syndromes, both of which are related to the unstable expansion of tri-nucleotide CAG repeats in the coding region of the related ATXN2 and ATXN3 genes, respectively. The poly-glutamine (poly-Q) tract encoded by the CAG repeats has long been recognized as an important factor in disease pathogenesis and progress. In this study, using the I-TASSER method for 3D structure prediction, we investigated the effect of poly-Q tract enlargement on the structure and folding of ataxin-2 and ataxin-3 proteins. Our results show good agreement with the known experimental structures of the Josephin and UIM domains providing credence to the simulation results presented here, which show that the enlargement of the poly-Q region not only affects the local structure of these regions but also affects the structures of functional domains as well as the whole protein. The changes observed in the predicted models of the UIM domains in ataxin-3 when the poly-Q track is enlarged provide new insights on possible pathogenic mechanisms. PMID:26861241

  16. Firefighter Safety Zone: The effect of terrain slope of separation distance

    Treesearch

    Bret Butler; Jason Forthofer

    2010-01-01

    Perhaps one of the most critical decisions made on wildland fires is the identification of suitable safety zones for firefighters during daily fire management operations. To be effective (timely, repeatable, and accurate), these decisions rely on good training and good judgement. The current safety zone guidelines used in the US (see fig. 1) and published in the...

  17. Applicability Assessment of Uavsar Data in Wetland Monitoring: a Case Study of Louisiana Wetland

    NASA Astrophysics Data System (ADS)

    Zhao, J.; Niu, Y.; Lu, Z.; Yang, J.; Li, P.; Liu, W.

    2018-04-01

    Wetlands are highly productive and support a wide variety of ecosystem goods and services. Monitoring wetland is essential and potential. Because of the repeat-pass nature of satellite orbit and airborne, time-series of remote sensing data can be obtained to monitor wetland. UAVSAR is a NASA L-band synthetic aperture radar (SAR) sensor compact pod-mounted polarimetric instrument for interferometric repeat-track observations. Moreover, UAVSAR images can accurately map crustal deformations associated with natural hazards, such as volcanoes and earthquakes. And its polarization agility facilitates terrain and land-use classification and change detection. In this paper, the multi-temporal UAVSAR data are applied for monitoring the wetland change. Using the multi-temporal polarimetric SAR (PolSAR) data, the change detection maps are obtained by unsupervised and supervised method. And the coherence is extracted from the interfometric SAR (InSAR) data to verify the accuracy of change detection map. The experimental results show that the multi-temporal UAVSAR data is fit for wetland monitor.

  18. A clinical technique for virtual articulator mounting with natural head position by using calibrated stereophotogrammetry.

    PubMed

    Lam, Walter Y H; Hsung, Richard T C; Choi, Winnie W S; Luk, Henry W K; Cheng, Leo Y Y; Pow, Edmond H N

    2017-09-29

    Accurate articulator-mounted casts are essential for occlusion analysis and for fabrication of dental prostheses. Although the axis orbital plane has been commonly used as the reference horizontal plane, some clinicians prefer to register the horizontal plane with a spirit level when the patient is in the natural head position (NHP) to avoid anatomic landmark variations. This article presents a digital workflow for registering the patient's horizontal plane in NHP on a virtual articulator. An orientation reference board is used to calibrate a stereophotogrammetry device and a 3-dimensional facial photograph with the patient in NHP. The horizontal plane can then be automatically registered to the patient's virtual model and aligned to the virtual articulator at the transverse horizontal axis level. This technique showed good repeatability with positional differences of less than 1 degree and 1 mm in 5 repeated measurements in 1 patient. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Acute Subdural Hematoma in a Judo Player with Repeated Head Injuries.

    PubMed

    Yokota, Hiroshi; Ida, Yuki

    2016-07-01

    Acute subdural hematoma (ASDH) is the most important cause of severe head injuries occurring during judo practice in Japan. Repeated head injuries have been reported as a cause of fatal ASDH, although the mechanism remains unknown. A 16-year-old boy visited an emergency department with vomiting 3 days after a strong blow to the occipital region during judo practice. Although computed tomography was performed at that time, a small interhemispheric ASDH was overlooked. The patient sustained another head injury 19 days after the first, which led to convulsions and disturbance of consciousness. The ASDH was increased in size on computed tomography. We performed a surgical evacuation, which revealed tearing of a bridging vein, after which the patient showed a good recovery. It is important to be aware of the possibility of a small ASDH in concussed judo players after an initial impact, which may lead to subsequent fatal ASDH after another impact incident. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Cooperative Networks: Altruism, Group Solidarity, Reciprocity, and Sanctioning in Ugandan Producer Organizations.

    PubMed

    Baldassarri, Delia

    2015-09-01

    Repeated interaction and social networks are commonly considered viable solutions to collective action problems. This article identifies and systematically measures four general mechanisms--that is, generalized altruism, group solidarity, reciprocity, and the threat of sanctioning--and tests which of them brings about cooperation in the context of Ugandan producer organizations. Using an innovative methodological framework that combines "lab-in-the-field" experiments with survey interviews and complete social networks data, the article goes beyond the assessment of a relationship between social networks and collective outcomes to study the mechanisms that favor cooperative behavior. The article first establishes a positive relationship between position in the network structure and propensity to cooperate in the producer organization and then uses farmers' behavior in dictator and public goods games to test different mechanisms that may account for such a relationship. Results show that cooperation is induced by patterns of reciprocity that emerge through repeated interaction rather than other-regarding preferences like altruism or group solidarity.

  1. Preparation of highly stable fullerene C60 decorated graphene oxide nanocomposite and its sensitive electrochemical detection of dopamine in rat brain and pharmaceutical samples.

    PubMed

    Thirumalraj, Balamurugan; Palanisamy, Selvakumar; Chen, Shen-Ming; Lou, Bih-Show

    2016-01-15

    The research community has continuously paid much attention on the preparation of hybrid of carbon nanomaterials owing to combine their unique properties. Herein, we report the preparation of highly stable fullerene C60 (C60) wrapped graphene oxide (GO) nanocomposite by using a simple sonication method. The fabricated GO-C60 nanocomposite modified glassy carbon electrode shows a good sensitivity and lower oxidation overpotential towards dopamine (DA) than that of pristine GO and C60. The fabricated sensor detects the DA in the linear response range of 0.02-73.5μM. The limit of detection is estimated to be 0.008μM based on 3σ with a sensitivity of 4.23μAμM(-1)cm(-2). The fabricated sensor also exhibits other features such as good selectivity, stability, reproducibility and repeatability. The proposed sensor exhibits good practicality towards the detection of DA in rat brain and commercial DA injection samples. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Research on pressure tactile sensing technology based on fiber Bragg grating array

    NASA Astrophysics Data System (ADS)

    Song, Jinxue; Jiang, Qi; Huang, Yuanyang; Li, Yibin; Jia, Yuxi; Rong, Xuewen; Song, Rui; Liu, Hongbin

    2015-09-01

    A pressure tactile sensor based on the fiber Bragg grating (FBG) array is introduced in this paper, and the numerical simulation of its elastic body was implemented by finite element software (ANSYS). On the basis of simulation, fiber Bragg grating strings were implanted in flexible silicone to realize the sensor fabrication process, and a testing system was built. A series of calibration tests were done via the high precision universal press machine. The tactile sensor array perceived external pressure, which is demodulated by the fiber grating demodulation instrument, and three-dimension pictures were programmed to display visually the position and size. At the same time, a dynamic contact experiment of the sensor was conducted for simulating robot encountering other objects in the unknown environment. The experimental results show that the sensor has good linearity, repeatability, and has the good effect of dynamic response, and its pressure sensitivity was 0.03 nm/N. In addition, the sensor also has advantages of anti-electromagnetic interference, good flexibility, simple structure, low cost and so on, which is expected to be used in the wearable artificial skin in the future.

  3. Reputation and Competition in a Hidden Action Model

    PubMed Central

    Fedele, Alessandro; Tedeschi, Piero

    2014-01-01

    The economics models of reputation and quality in markets can be classified in three categories. (i) Pure hidden action, where only one type of seller is present who can provide goods of different quality. (ii) Pure hidden information, where sellers of different types have no control over product quality. (iii) Mixed frameworks, which include both hidden action and hidden information. In this paper we develop a pure hidden action model of reputation and Bertrand competition, where consumers and firms interact repeatedly in a market with free entry. The price of the good produced by the firms is contractible, whilst the quality is noncontractible, hence it is promised by the firms when a contract is signed. Consumers infer future quality from all available information, i.e., both from what they know about past quality and from current prices. According to early contributions, competition should make reputation unable to induce the production of high-quality goods. We provide a simple solution to this problem by showing that high quality levels are sustained as an outcome of a stationary symmetric equilibrium. PMID:25329387

  4. Reputation and competition in a hidden action model.

    PubMed

    Fedele, Alessandro; Tedeschi, Piero

    2014-01-01

    The economics models of reputation and quality in markets can be classified in three categories. (i) Pure hidden action, where only one type of seller is present who can provide goods of different quality. (ii) Pure hidden information, where sellers of different types have no control over product quality. (iii) Mixed frameworks, which include both hidden action and hidden information. In this paper we develop a pure hidden action model of reputation and Bertrand competition, where consumers and firms interact repeatedly in a market with free entry. The price of the good produced by the firms is contractible, whilst the quality is noncontractible, hence it is promised by the firms when a contract is signed. Consumers infer future quality from all available information, i.e., both from what they know about past quality and from current prices. According to early contributions, competition should make reputation unable to induce the production of high-quality goods. We provide a simple solution to this problem by showing that high quality levels are sustained as an outcome of a stationary symmetric equilibrium.

  5. On the Performance of the Marginal Homogeneity Test to Detect Rater Drift.

    PubMed

    Sgammato, Adrienne; Donoghue, John R

    2018-06-01

    When constructed response items are administered repeatedly, "trend scoring" can be used to test for rater drift. In trend scoring, raters rescore responses from the previous administration. Two simulation studies evaluated the utility of Stuart's Q measure of marginal homogeneity as a way of evaluating rater drift when monitoring trend scoring. In the first study, data were generated based on trend scoring tables obtained from an operational assessment. The second study tightly controlled table margins to disentangle certain features present in the empirical data. In addition to Q , the paired t test was included as a comparison, because of its widespread use in monitoring trend scoring. Sample size, number of score categories, interrater agreement, and symmetry/asymmetry of the margins were manipulated. For identical margins, both statistics had good Type I error control. For a unidirectional shift in margins, both statistics had good power. As expected, when shifts in the margins were balanced across categories, the t test had little power. Q demonstrated good power for all conditions and identified almost all items identified by the t test. Q shows substantial promise for monitoring of trend scoring.

  6. Piloted Evaluation of a UH-60 Mixer Equivalent Turbulence Simulation Model

    NASA Technical Reports Server (NTRS)

    Lusardi, Jeff A.; Blanken, Chris L.; Tischeler, Mark B.

    2002-01-01

    A simulation study of a recently developed hover/low speed Mixer Equivalent Turbulence Simulation (METS) model for the UH-60 Black Hawk helicopter was conducted in the NASA Ames Research Center Vertical Motion Simulator (VMS). The experiment was a continuation of previous work to develop a simple, but validated, turbulence model for hovering rotorcraft. To validate the METS model, two experienced test pilots replicated precision hover tasks that had been conducted in an instrumented UH-60 helicopter in turbulence. Objective simulation data were collected for comparison with flight test data, and subjective data were collected that included handling qualities ratings and pilot comments for increasing levels of turbulence. Analyses of the simulation results show good analytic agreement between the METS model and flight test data, with favorable pilot perception of the simulated turbulence. Precision hover tasks were also repeated using the more complex rotating-frame SORBET (Simulation Of Rotor Blade Element Turbulence) model to generate turbulence. Comparisons of the empirically derived METS model with the theoretical SORBET model show good agreement providing validation of the more complex blade element method of simulating turbulence.

  7. Fabrication and Characterization of Flexible and Miniaturized Humidity Sensors Using Screen-Printed TiO2 Nanoparticles as Sensitive Layer

    PubMed Central

    Dubourg, Georges; Segkos, Apostolos; Katona, Jaroslav; Radović, Marko; Savić, Slavica; Crnojević-Bengin, Vesna

    2017-01-01

    This paper describes the fabrication and the characterization of an original example of a miniaturized resistive-type humidity sensor, printed on flexible substrate in a large-scale manner. The fabrication process involves laser ablation for the design of interdigitated electrodes on PET (Poly-Ethylene Terephthalate) substrate and a screen-printing process for the deposition of the sensitive material, which is based on TiO2 nanoparticles. The laser ablation process was carefully optimized to obtain micro-scale and well-resolved electrodes on PET substrate. A functional paste based on cellulose was prepared in order to allow the precise screen-printing of the TiO2 nanoparticles as sensing material on the top of the electrodes. The current against voltage (I–V) characteristic of the sensor showed good linearity and potential for low-power operation. The results of a humidity-sensing investigation and mechanical testing showed that the fabricated miniaturized sensors have excellent mechanical stability, sensing characteristics, good repeatability, and relatively fast response/recovery times operating at room temperature. PMID:28800063

  8. Mesoporous Nickel Oxide (NiO) Nanopetals for Ultrasensitive Glucose Sensing

    NASA Astrophysics Data System (ADS)

    Mishra, Suryakant; Yogi, Priyanka; Sagdeo, P. R.; Kumar, Rajesh

    2018-01-01

    Glucose sensing properties of mesoporous well-aligned, dense nickel oxide (NiO) nanostructures (NSs) in nanopetals (NPs) shape grown hydrothermally on the FTO-coated glass substrate has been demonstrated. The structural study based investigations of NiO-NPs has been carried out by X-ray diffraction (XRD), electron and atomic force microscopies, energy dispersive X-ray (EDX), and X-ray photospectroscopy (XPS). Brunauer-Emmett-Teller (BET) measurements, employed for surface analysis, suggest NiO's suitability for surface activity based glucose sensing applications. The glucose sensor, which immobilized glucose on NiO-NPs@FTO electrode, shows detection of wide range of glucose concentrations with good linearity and high sensitivity of 3.9 μA/μM/cm2 at 0.5 V operating potential. Detection limit of as low as 1 μΜ and a fast response time of less than 1 s was observed. The glucose sensor electrode possesses good anti-interference ability, stability, repeatability & reproducibility and shows inert behavior toward ascorbic acid (AA), uric acid (UA) and dopamine acid (DA) making it a perfect non-enzymatic glucose sensor.

  9. Phonological learning in semantic dementia.

    PubMed

    Jefferies, Elizabeth; Bott, Samantha; Ehsan, Sheeba; Lambon Ralph, Matthew A

    2011-04-01

    Patients with semantic dementia (SD) have anterior temporal lobe (ATL) atrophy that gives rise to a highly selective deterioration of semantic knowledge. Despite pronounced anomia and poor comprehension of words and pictures, SD patients have well-formed, fluent speech and normal digit span. Given the intimate connection between phonological STM and word learning revealed by both neuropsychological and developmental studies, SD patients might be expected to show good acquisition of new phonological forms, even though their ability to map these onto meanings is impaired. In contradiction of these predictions, a limited amount of previous research has found poor learning of new phonological forms in SD. In a series of experiments, we examined whether SD patient, GE, could learn novel phonological sequences and, if so, under which circumstances. GE showed normal benefits of phonological knowledge in STM (i.e., normal phonotactic frequency and phonological similarity effects) but reduced support from semantic memory (i.e., poor immediate serial recall for semantically degraded words, characterised by frequent item errors). Next, we demonstrated normal learning of serial order information for repeated lists of single-digit number words using the Hebb paradigm: these items were well-understood allowing them to be repeated without frequent item errors. In contrast, patient GE showed little learning of nonsense syllable sequences using the same Hebb paradigm. Detailed analysis revealed that both GE and the controls showed a tendency to learn their own errors as opposed to the target items. Finally, we showed normal learning of phonological sequences for GE when he was prevented from repeating his errors. These findings confirm that the ATL atrophy in SD disrupts phonological processing for semantically degraded words but leaves the phonological architecture intact. Consequently, when item errors are minimised, phonological STM can support the acquisition of new phoneme sequences in patients with SD. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Suitability of open-field autorefractors as pupillometers and instrument design effects.

    PubMed

    Otero, Carles; Aldaba, Mikel; Ferrer, Oriol; Gascón, Andrea; Ondategui-Parra, Juan C; Pujol, Jaume

    2017-01-01

    To determine the agreement and repeatability of the pupil measurement obtained with VIP-200 (Neuroptics), PowerRef II (Plusoptix), WAM-5500 (Grand Seiko) and study the effects of instrument design on pupillometry. Forty patients were measured twice in low, mid and high mesopic. Repeatability was analyzed with the within-subject standard deviation (Sw) and paired t -tests. Agreement was studied with Bland-Altman plots and repeated measures ANOVA. Instrument design analysis consisted on measuring pupil size with PowerRef II simulating monocular and binocular conditions as well as with proximity cues and without proximity cues. The mean difference (±standard deviation) between test-retest for low, mid and high mesopic conditions were, respectively: -0.09 (±0.16), -0.05 (±0.18) and -0.08 (±0.23) mm for Neuroptics, -0.05 (±0.17), -0.12 (±0.23) and -0.17 (±0.34) mm for WAM-5500, -0.04 (±0.27), -0.13 (±0.37) and -0.11 (±0.28) mm for PowerRef II. Regarding agreement with Neuroptics, the mean difference for low, mid and high mesopic conditions were, respectively: -0.48 (±0.35), -0.83 (±0.52) and -0.38 (±0.56) mm for WAM-5500, -0.28 (±0.56), -0.70 (±0.55) and -0.61 (±0.54) mm for PowerRef II. The mean difference of binocular minus monocular pupil measurements was: -0.83 (±0.87) mm; and with proximity cues minus without proximity cues was: -0.30 (±0.77) mm. All the instruments show similar repeat-ability. In all illumination conditions, agreement of Neuroptics with WAM-5500 and PowerRef II is not good enough, which can be partially induced due to their open field design.

  11. Fabrication of polymer micro-lens array with pneumatically diaphragm-driven drop-on-demand inkjet technology.

    PubMed

    Xie, Dan; Zhang, Honghai; Shu, Xiayun; Xiao, Junfeng

    2012-07-02

    The paper reports an effective method to fabricate micro-lens arrays with the ultraviolet-curable polymer, using an original pneumatically diaphragm-driven drop-on-demand inkjet system. An array of plano convex micro-lenses can be formed on the glass substrate due to surface tension and hydrophobic effect. The micro-lens arrays have uniform focusing function, smooth and real planar surface. The fabrication process showed good repeatability as well, fifty micro-lenses randomly selected form 9 × 9 miro-lens array with an average diameter of 333.28μm showed 1.1% variations. Also, the focal length, the surface roughness and optical property of the fabricated micro-lenses are measured, analyzed and proved satisfactory. The technique shows great potential for fabricating polymer micro-lens arrays with high flexibility, simple technological process and low production cost.

  12. In-situ pre-concentration through repeated sampling and pyrolysis for ultrasensitive determination of thallium in drinking water by electrothermal atomic absorption spectrometry.

    PubMed

    Liu, Liwei; Zheng, Huaili; Xu, Bincheng; Xiao, Lang; Chigan, Yong; Zhangluo, Yilan

    2018-03-01

    In this paper, a procedure for in-situ pre-concentration in graphite furnace by repeated sampling and pyrolysis is proposed for the determination of ultra-trace thallium in drinking water by graphite furnace atomic absorption spectrometry (GF-AAS). Without any other laborious enrichment processes that routinely result in analyte loss and contamination, thallium was directly concentrated in the graphite furnace automatically and subsequently subject to analysis. The effects of several key factors, such as the temperature for pyrolysis and atomization, the chemical modifier, and the repeated sampling times were investigated. Under the optimized conditions, a limit of detection of 0.01µgL -1 was obtained, which fulfilled thallium determination in drinking water by GB 5749-2006 regulated by China. Successful analysis of thallium in certified water samples and drinking water samples was demonstrated, with analytical results in good agreement with the certified values and those by inductively coupled plasma mass spectrometry (ICP-MS), respectively. Routine spike-recovery tests with randomly selected drinking water samples showed satisfactory results of 80-96%. The proposed method is simple and sensitive for screening of ultra-trace thallium in drinking water samples. Copyright © 2017. Published by Elsevier B.V.

  13. Reproducibility of repeated measurements with the Kikuhime pressure sensor under pressure garments in burn scar treatment.

    PubMed

    Van den Kerckhove, Eric; Fieuws, Steffen; Massagé, Patrick; Hierner, Robert; Boeckx, Willy; Deleuze, Jean-Paul; Laperre, Jan; Anthonissen, Mieke

    2007-08-01

    This study investigated the reproducibility of repeated measurements with the Kikuhime pressure sensor under two different types of pressure garments used in the treatment and prevention of scars after burns. Also efficiency of garments was assessed in clinical circumstances by assessing pressure loss and residual pressure after 1 month. Intra- and inter-observer reproducibility and repeated measurements with 1-month time lapse were examined on 55 sites in 26 subjects by means of intra-class correlation coefficients and standard error of measurements. Results showed good to excellent ICC and low SEMs in the two conditions. There was a significant difference in pressure after 1 month between elastic tricot and weft knit garments, although evolution of pressure loss after 1 month was similar. Concerning different locations, there was a significant difference in pressure loss after 1 month between gloves and sleeves with the largest pressure loss for sleeves. Considering these results we concluded that the Kikuhime pressure sensor provides valid and reliable information and can be used in comparative clinical trials to evaluate pressure garments used in burn scar treatment. Secondly, elastic tricot garments in our study tended to have higher clinical pressures but both types of garments had similar pressure loss over time.

  14. The Beauty of the Acronym!: "Good Management Begins with Good People"

    ERIC Educational Resources Information Center

    Vicars, Dennis

    2010-01-01

    Acronyms are not only short and catchy, but they may also help one to quickly hone in on what's important and to set priorities. In a field that seems to bask in process, over-analysis, and repeated discussion, the acronym "cuts to the chase" and keeps everyone on the same page. The last Management Maxim column ("Exchange," March/April 2010)…

  15. Clostridium difficile Infection

    MedlinePlus

    ... These drugs can make your infection worse. Certain probiotics, or “good bacteria,” may help prevent repeat C. ... Your Doctor Drugs, Procedures & Devices Over-the-counter Products Procedures & Devices Prescription Medicines Health Tools Dictionary Symptom ...

  16. The human genome as "common good".

    PubMed

    Vesto, Aurora

    2017-07-01

    Objectivity of rights must be rebuilt in a dimension not only structural but also functional, despite being a "thing" that exactly repeats itself, it differs depending on what the person intended to make.

  17. Improved variance estimation of classification performance via reduction of bias caused by small sample size.

    PubMed

    Wickenberg-Bolin, Ulrika; Göransson, Hanna; Fryknäs, Mårten; Gustafsson, Mats G; Isaksson, Anders

    2006-03-13

    Supervised learning for classification of cancer employs a set of design examples to learn how to discriminate between tumors. In practice it is crucial to confirm that the classifier is robust with good generalization performance to new examples, or at least that it performs better than random guessing. A suggested alternative is to obtain a confidence interval of the error rate using repeated design and test sets selected from available examples. However, it is known that even in the ideal situation of repeated designs and tests with completely novel samples in each cycle, a small test set size leads to a large bias in the estimate of the true variance between design sets. Therefore different methods for small sample performance estimation such as a recently proposed procedure called Repeated Random Sampling (RSS) is also expected to result in heavily biased estimates, which in turn translates into biased confidence intervals. Here we explore such biases and develop a refined algorithm called Repeated Independent Design and Test (RIDT). Our simulations reveal that repeated designs and tests based on resampling in a fixed bag of samples yield a biased variance estimate. We also demonstrate that it is possible to obtain an improved variance estimate by means of a procedure that explicitly models how this bias depends on the number of samples used for testing. For the special case of repeated designs and tests using new samples for each design and test, we present an exact analytical expression for how the expected value of the bias decreases with the size of the test set. We show that via modeling and subsequent reduction of the small sample bias, it is possible to obtain an improved estimate of the variance of classifier performance between design sets. However, the uncertainty of the variance estimate is large in the simulations performed indicating that the method in its present form cannot be directly applied to small data sets.

  18. Use of repeat anterior maxillary distraction to correct residual midface hypoplasia in cleft patients

    PubMed Central

    2017-01-01

    Objectives The study was designed to evaluate the efficacy of performing a second, repeat anterior maxillary distraction (AMD) to treat residual cleft maxillary hypoplasia. Materials and Methods Five patients between the ages of 12 to 15 years with a history of AMD and with residual cleft maxillary hypoplasia were included in the study. Inclusion was irrespective of gender, type of cleft lip and palate, and the amount of advancement needed. Repeat AMD was executed in these patients 4 to 5 years after the primary AMD procedure to correct the cleft maxillary hypoplasia that had developed since the initial procedure. Orthopantomogram (OPG) and lateral cephalograms were taken for evaluation preoperatively, immediately after distraction, after consolidation, and one year postoperatively. The data obtained was tabulated and a Mann Whitney U-test was used for statistical comparisons. Results At the time of presentation, a residual maxillary hypoplasia was observed with a well maintained distraction gap on the OPG which ruled out the occurrence of a relapse. Favorable movement of the segments without any resistance was seen in all patients. Mean maxillary advancement of 10.56 mm was achieved at repeat AMD. Statistically significant increases in midfacial length, SNA angle, and nasion perpendicular to point A distance was achieved (P=0.012, P=0.011, and P=0.012, respectively). Good profile was achieved for all patients. Minimal transient complications, for example anterior open bite and bleeding episodes, were managed. Conclusion Addressing the problem of cleft maxillary hypoplasia at an early age (12–15 years) is beneficial for the child. Residual hypoplasia may develop in some patients, which may require additional corrective procedures. The results of our study show that AMD can be repeated when residual deformity develops with the previous procedure having no negative impact on the results of the repeat procedure. PMID:29333371

  19. Assessment of different methods to estimate bovine colostrum quality on farm.

    PubMed

    Bartens, M-C; Drillich, M; Rychli, K; Iwersen, M; Arnholdt, T; Meyer, L; Klein-Jöbstl, D

    2016-09-01

    To evaluate two different hydrometers and an optical and a digital Brix refractometer for the assessment of bovine colostrum quality, in terms of accuracy and precision compared with the measurement of IgG concentrations using radial immunodiffusion (RID), and to evaluate the reliability and repeatability of the Brix refractometers. To determine reliability and repeatability, 145 colostrum samples were tested by two independent observers twice, using the optical and digital Brix refractometers. A further 193 colostrum samples from Holstein cows were collected on one commercial dairy farm at first milking and tested with two hydrometers and an optical and digital Brix refractometer. An aliquot of each sample was frozen for RID measurement of IgG concentrations and samples were classified as poor (≤50 g IgG/L) or good (>50 g IgG/L) quality colostrum. Intraclass correlation coefficients (ICC) were used to determine inter- and intra-observer reliability and repeatability. Optimised cut-off values for the four devices were determined using receiver operating characteristics (ROC) analysis with the RID results as the reference. Using these cut-offs, sensitivities and specificities for determining good quality colostrum were calculated. The ICC for inter-observer reliability was 0.98 for the optical Brix refractometer, and for intra-observer repeatability was 0.97 and 0.98 for the optical and the digital Brix refractometers, respectively. For the 193 colostrum samples, 67 (34.7%) had concentrations of IgG ≤50 g/L determined by RID. Optimised cut-off values evaluated by ROC analysis were higher for all devices compared with manufacturer reference or previously published values. Using these values, the sensitivities for the two hydrometers, and the optical and the digital Brix refractometers were 0.73, 0.71, 0.56 and 0.79, respectively; specificities were 0.72, 0.61, 0.90 and 0.69, respectively. The Brix refractometers provided the most accurate assessment of colostrum quality of the devices evaluated, and demonstrated excellent precision in terms of repeatability. To provide optimal health for newborn calves, a sufficient intake of good quality colostrum is essential. The Brix refractometers provide rapid, convenient tools for classification of colostrum quality.

  20. Collective states in social systems with interacting learning agents

    NASA Astrophysics Data System (ADS)

    Semeshenko, Viktoriya; Gordon, Mirta B.; Nadal, Jean-Pierre

    2008-08-01

    We study the implications of social interactions and individual learning features on consumer demand in a simple market model. We consider a social system of interacting heterogeneous agents with learning abilities. Given a fixed price, agents repeatedly decide whether or not to buy a unit of a good, so as to maximize their expected utilities. This model is close to Random Field Ising Models, where the random field corresponds to the idiosyncratic willingness to pay. We show that the equilibrium reached depends on the nature of the information agents use to estimate their expected utilities. It may be different from the systems’ Nash equilibria.

  1. Mass measurement of 1 kg silicon spheres to establish a density standard

    NASA Astrophysics Data System (ADS)

    Mizushima, S.; Ueki, M.; Fujii, K.

    2004-04-01

    Air buoyancy causes a significant systematic effect in precision mass determination of 1 kg silicon spheres. In order to correct this effect accurately, mass measurement of the silicon sphere was conducted using buoyancy artefacts; additionally, in order to stabilize atmospheric conditions, we used a vacuum chamber in which a mass comparator had been installed. The silicon sphere was also weighed in vacuum to verify the air buoyancy correction. Mass differences measured in air and in vacuum showed good agreement with each other in spite of the desorption effect from weight surfaces. Furthermore, the result of weighing under vacuum conditions demonstrated better repeatability than that obtained in air.

  2. 40 CFR 1065.320 - Fuel-flow calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...

  3. 40 CFR 1065.320 - Fuel-flow calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...

  4. 40 CFR 1065.320 - Fuel-flow calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...

  5. 40 CFR 1065.320 - Fuel-flow calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...

  6. 40 CFR 1065.320 - Fuel-flow calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... manufacturer's instructions and use good engineering judgment to repeat the calibration. (b) You may also develop a procedure based on a chemical balance of carbon or oxygen in engine exhaust. (c) You may remove...

  7. 12 CFR 308.132 - Assessment of penalties.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... good faith of the bank or official, the gravity of the violation, the history of previous violations... bank's delinquency is lengthy or the bank has been delinquent repeatedly in making or publishing its...

  8. Absence of chronic traumatic encephalopathy in retired football players with multiple concussions and neurological symptomatology.

    PubMed

    Hazrati, Lili-Naz; Tartaglia, Maria C; Diamandis, Phedias; Davis, Karen D; Green, Robin E; Wennberg, Richard; Wong, Janice C; Ezerins, Leo; Tator, Charles H

    2013-01-01

    Chronic traumatic encephalopathy (CTE) is the term coined for the neurodegenerative disease often suspected in athletes with histories of repeated concussion and progressive dementia. Histologically, CTE is defined as a tauopathy with a distribution of tau-positive neurofibrillary tangles (NFTs) that is distinct from other tauopathies, and usually shows an absence of beta-amyloid deposits, in contrast to Alzheimer's disease (AD). Although the connection between repeated concussions and CTE-type neurodegeneration has been recently proposed, this causal relationship has not yet been firmly established. Also, the prevalence of CTE among athletes with multiple concussions is unknown. We performed a consecutive case series brain autopsy study on six retired professional football players from the Canadian Football League (CFL) with histories of multiple concussions and significant neurological decline. All participants had progressive neurocognitive decline prior to death; however, only 3 cases had post-mortem neuropathological findings consistent with CTE. The other 3 participants had pathological diagnoses of AD, amyotrophic lateral sclerosis (ALS), and Parkinson's disease (PD). Moreover, the CTE cases showed co-morbid pathology of cancer, vascular disease, and AD. Our case studies highlight that not all athletes with history of repeated concussions and neurological symptomology present neuropathological changes of CTE. These preliminary findings support the need for further research into the link between concussion and CTE as well as the need to expand the research to other possible causes of taupathy in athletes. They point to a critical need for prospective studies with good sampling methods to allow us to understand the relationship between multiple concussions and the development of CTE.

  9. [Establishment of Automation System for Detection of Alcohol in Blood].

    PubMed

    Tian, L L; Shen, Lei; Xue, J F; Liu, M M; Liang, L J

    2017-02-01

    To establish an automation system for detection of alcohol content in blood. The determination was performed by automated workstation of extraction-headspace gas chromatography (HS-GC). The blood collection with negative pressure, sealing time of headspace bottle and sample needle were checked and optimized in the abstraction of automation system. The automatic sampling was compared with the manual sampling. The quantitative data obtained by the automated workstation of extraction-HS-GC for alcohol was stable. The relative differences of two parallel samples were less than 5%. The automated extraction was superior to the manual extraction. A good linear relationship was obtained at the alcohol concentration range of 0.1-3.0 mg/mL ( r ≥0.999) with good repeatability. The method is simple and quick, with more standard experiment process and accurate experimental data. It eliminates the error from the experimenter and has good repeatability, which can be applied to the qualitative and quantitative detections of alcohol in blood. Copyright© by the Editorial Department of Journal of Forensic Medicine

  10. Application of methyl silane coated iron oxide magnetic nanoparticles for solid-phase extraction and determination of fat-soluble vitamins by high performance liquid chromatography.

    PubMed

    Momenbeik, Fariborz; Yazdani, Elham

    2015-01-01

    Methyl silane coated Fe3O4 magnetic nanoparticles were used for simultaneous extraction of the fat-soluble vitamins (FSVs). The amounts of extracted vitamins were determined by HPLC. The synthesized Fe3O4 nanoparticles were coated with silica and then modified with trimethoxymethylsilane (TMMS). The prepared particles were characterized by different methods. The best amounts of silica and TMMS in sorbent synthesis were 1.2 and 0.5 mL, respectively. The optimum pH values for the sample solution and washing buffer were 5 and 3, respectively. Application of 100 mg sorbent, 700 μL tetrahydrofuran, 5-fold dilution of the sample solution, and 1 min for sorption and desorption times were among the best conditions. At the optimum conditions, the calibration plots for each vitamin were obtained with good linearity (R(2) >0.9992) and suitable linear ranges. This method has a low LOD (<76.1 μg/mL), acceptable repeatability (RSD <5.63%) and reproducibility (RSD <4.71%), and good accuracy (recovery >90.3%). Preconcentration of low concentrations of vitamin D3 was performed, and results showed 3.7 times greater sensitivity after preconcentration. Finally, the amounts of the FSVs in pharmaceutical formulations were determined using the proposed method, and results showed good agreement with those reported by manufacturers.

  11. Inter- and intraobserver repeatability of the Salford Gait Tool: an observation-based clinical gait assessment tool.

    PubMed

    Toro, Brigitte; Nester, Christopher J; Farren, Pauline C

    2007-03-01

    To evaluate the inter- and intraobserver repeatability of the Salford Gait Tool (SF-GT), a new observation-based gait assessment tool for evaluating sagittal plane cerebral palsy (CP) gait. Masked comparative evaluation. University in the United Kingdom. A convenience sample of 23 pediatric physical therapists with varying degrees of clinical experience recruited from the Greater Manchester area. Participants viewed videotapes of the sagittal plane gait of 13 children and used the SF-GT to analyze their 13 different gait styles on 2 occasions. Eleven children had hemiplegic, diplegic, or quadriplegic CP and 2 were neurologically intact. Inter- and intraobserver repeatability of hip, knee, and ankle joint positions at 6 different phases of the gait cycle. The SF-GT demonstrated good interobserver (77%) and intraobserver (75%) repeatability. We have established that the SF-GT is a repeatable clinical assessment tool with which to guide the diagnosis, treatment planning, and evaluation of interventions by pediatric physical therapists of sagittal plane gait deviations in CP.

  12. Progression of Dysphagia in Spinocerebellar Ataxia Type 6.

    PubMed

    Isono, Chiharu; Hirano, Makito; Sakamoto, Hikaru; Ueno, Shuichi; Kusunoki, Susumu; Nakamura, Yusaku

    2017-06-01

    Spinocerebellar ataxia type 6 (SCA6), an autosomal dominant triplet repeat disease, predominantly affects the cerebellum with a late onset and generally good prognosis. Dysphagia is commonly associated with the outcomes of neurodegenerative diseases such as SCA6. Although the characteristics of dysphagia have been rarely reported in SCA6, our previous study indicated that dysphagia is generally milder in SCA6 than in SCA3, another inherited ataxia with multisystem involvement. However, abnormalities in the pharyngeal phase in SCA6 were indistinguishable from those in SCA3, with no explainable reason. To determine the reason, we repeatedly performed videofluoroscopic examinations (VF) in 14 patients with SCA6. The results showed that the gross progression of dysphagia was apparently slow, but four patients had progressive dysphagia at an early disease stage; dysphagia began within 10 years from the onset of ataxia and rapidly progressed. A common clinical feature of the four patients was a significantly older age at the onset of ataxia (74.0 vs. 60.3 years), associated with significantly shorter triplet repeats. This finding surprisingly indicated that patients who had shorter repeats and thereby later onset and potentially better prognoses were at risk for dysphagia-associated problems. Ischemic changes, homozygous mutation, and diabetes mellitus as well as aging might have contributed to the observed progressive dysphagia. We found that conventionally monitored somatosensory evoked potentials at least partly reflected progressive dysphagia. Despite the small study group, our findings suggest that clinicians should carefully monitor dysphagia in patients with SCA6 who are older at disease onset (>60 years).

  13. Characterization of the hyperrecombination phenotype of the pol3-t mutation of Saccharomyces cerevisiae.

    PubMed

    Galli, Alvaro; Cervelli, Tiziana; Schiestl, Robert H

    2003-05-01

    The DNA polymerase delta (Pol3p/Cdc2p) allele pol3-t of Saccharomyces cerevisiae has previously been shown to increase the frequency of deletions between short repeats (several base pairs), between homologous DNA sequences separated by long inverted repeats, and between distant short repeats, increasing the frequency of genomic deletions. We found that the pol3-t mutation increased intrachromosomal recombination events between direct DNA repeats up to 36-fold and interchromosomal recombination 14-fold. The hyperrecombination phenotype of pol3-t was partially dependent on the Rad52p function but much more so on Rad1p. However, in the double-mutant rad1 Delta rad52 Delta, the pol3-t mutation still increased spontaneous intrachromosomal recombination frequencies, suggesting that a Rad1p Rad52p-independent single-strand annealing pathway is involved. UV and gamma-rays were less potent inducers of recombination in the pol3-t mutant, indicating that Pol3p is partly involved in DNA-damage-induced recombination. In contrast, while UV- and gamma-ray-induced intrachromosomal recombination was almost completely abolished in the rad52 or the rad1 rad52 mutant, there was still good induction in those mutants in the pol3-t background, indicating channeling of lesions into the above-mentioned Rad1p Rad52p-independent pathway. Finally, a heterozygous pol3-t/POL3 mutant also showed an increased frequency of deletions and MMS sensitivity at the restrictive temperature, indicating that even a heterozygous polymerase delta mutation might increase the frequency of genetic instability.

  14. Agreement and repeatability of objective systems for assessment of the tear film.

    PubMed

    Fernández, Joaquín; Rodríguez-Vallejo, Manuel; Martínez, Javier; Tauste, Ana; García-Montesinos, Javier; Piñero, David P

    2018-04-18

    To assess the agreement and repeatability of two objective systems for measuring the tear film stability. Retrospective analysis of the tear film stability of 99 healthy right eyes measured with a videokeratoscope (VK) and the Optical Quality Analysis System (OQAS, Visiometrics). Two consecutive measures were taken with both systems, with an interval of 10 min between them. Variables included in the study were first and mean non-invasive break-up times (NIBUT and MNIBUT) measured with VK, and mean and standard deviation of the optical scattering index (OSIm and OSIsd) measured with OQAS. The agreement and repeatability of grading scales provided by both devices were also evaluated using the Cohen's k with quadratic weights. The Ocular Surface Disease index (OSDI) questionnaire was also passed out to all subjects. Correlations and associations between subjective and objective metrics were analyzed. Significant differences were found between consecutive measurements of NIBUT (p = 0.04) and MNIBUT (p = 0.01), but not for OSIm (p = 0.11) and OSIsd (p = 0.50). Grading scales resulted in fair (k = 0.20) or poor agreement (k = 0.04) between systems depending if the first or second trial was considered. The repeatability of the grading scale was good for OQAS (k = 0.59) and fair for VK (k = 0.37). No significant correlations or associations were found between OSDI and any of the metrics obtained with both devices (p ≥ 0.36). The two devices evaluated cannot be used interchangeably for the assessment of tear film stability. Good intrasession repeatability was obtained for tear film grading of the OQAS whereas it was fair for VK.

  15. Detection of Organophosphorus Pesticides with Colorimetry and Computer Image Analysis.

    PubMed

    Li, Yanjie; Hou, Changjun; Lei, Jincan; Deng, Bo; Huang, Jing; Yang, Mei

    2016-01-01

    Organophosphorus pesticides (OPs) represent a very important class of pesticides that are widely used in agriculture because of their relatively high-performance and moderate environmental persistence, hence the sensitive and specific detection of OPs is highly significant. Based on the inhibitory effect of acetylcholinesterase (AChE) induced by inhibitors, including OPs and carbamates, a colorimetric analysis was used for detection of OPs with computer image analysis of color density in CMYK (cyan, magenta, yellow and black) color space and non-linear modeling. The results showed that there was a gradually weakened trend of yellow intensity with the increase of the concentration of dichlorvos. The quantitative analysis of dichlorvos was achieved by Artificial Neural Network (ANN) modeling, and the results showed that the established model had a good predictive ability between training sets and predictive sets. Real cabbage samples containing dichlorvos were detected by colorimetry and gas chromatography (GC), respectively. The results showed that there was no significant difference between colorimetry and GC (P > 0.05). The experiments of accuracy, precision and repeatability revealed good performance for detection of OPs. AChE can also be inhibited by carbamates, and therefore this method has potential applications in real samples for OPs and carbamates because of high selectivity and sensitivity.

  16. [Development and evaluation of a rapid PCR detection kit for Ophiocordyceps sinensis].

    PubMed

    Hou, Fei-Xia; Cao, Jing; Wang, Sha-Sha; Wang, Xi; Yuan, Yuan; Peng, Cheng; Wan, De-Guang; Guo, Jin-Lin

    2017-03-01

    Ophiocordyceps sinensis is a valuable traditional Chinese medicine. Due to resource shortage, expensive price and huge market demand, there are many adulterants of O. sinensis in markets. Therefore, it is necessary to establish a rapid and effective method for distinguishing O. sinensis. Based on the species-specific PCR of O. sinensis, this study developed a detection kit by optimizing the components and evaluated the specificity, detection limit, repeatability and shelf life of the kit. The results showed that when the quality of O. sinensis accounted for more than 1/200 of that mixture, it could be detected successfully. Moreover, only O. sinensis could be amplified and glowed bright green fluorescence under ultraviolet light. The kit was still in effect when it was placed at 37 ℃ for three days, which indicated that it was stable and effective for one year stored in 4 ℃. The kit in the same batch under different operation conditions, and in different batch under the same operation conditions gave the same result and accuracy, which showed good repeatability of the kit. It is simple, rapid and accurate to distinguish O. sinensis from its adulterants using the kit, and lays the foundation for commercialization of traditional Chinese medicine fast detection kit. Copyright© by the Chinese Pharmaceutical Association.

  17. Instrumenting Beliefs in Threshold Public Goods

    PubMed Central

    2016-01-01

    Understanding the causal impact of beliefs on contributions in Threshold Public Goods (TPGs) is particularly important since the social optimum can be supported as a Nash Equilibrium and best-response contributions are a function of beliefs. Unfortunately, investigations of the impact of beliefs on behavior are plagued with endogeneity concerns. We create a set of instruments by cleanly and exogenously manipulating beliefs without deception. Tests indicate that the instruments are valid and relevant. Perhaps surprisingly, we fail to find evidence that beliefs are endogenous in either the one-shot or repeated-decision settings. TPG allocations are determined by a base contribution and beliefs in a one shot-setting. In the repeated-decision environment, once we instrument for first-round allocations, we find that second-round allocations are driven equally by beliefs and history. Moreover, we find that failing to instrument prior decisions overstates their importance. PMID:26859492

  18. Self-enforcing strategies to deter free-riding in the climate change mitigation game and other repeated public good games

    PubMed Central

    Heitzig, Jobst; Lessmann, Kai; Zou, Yong

    2011-01-01

    As the Copenhagen Accord indicates, most of the international community agrees that global mean temperature should not be allowed to rise more than two degrees Celsius above preindustrial levels to avoid unacceptable damages from climate change. The scientific evidence distilled in the Fourth Assessment Report of the Intergovernmental Panel on Climate Change and recent reports by the US National Academies shows that this can only be achieved by vast reductions of greenhouse gas emissions. Still, international cooperation on greenhouse gas emissions reductions suffers from incentives to free-ride and to renegotiate agreements in case of noncompliance, and the same is true for other so-called “public good games.” Using game theory, we show how one might overcome these problems with a simple dynamic strategy of linear compensation when the parameters of the problem fulfill some general conditions and players can be considered to be sufficiently rational. The proposed strategy redistributes liabilities according to past compliance levels in a proportionate and timely way. It can be used to implement any given allocation of target contributions, and we prove that it has several strong stability properties. PMID:21903930

  19. Validity and reliability of a Swedish version of the Non-Communicating Children's Pain Checklist--Postoperative Version.

    PubMed

    Johansson, M; Carlberg, E B; Jylli, L

    2010-06-01

    To test the validity and reliability of a Swedish version of the Non-Communicating Children's Pain Checklist-Postoperative Version (NCCPC-PV). Thirty-two consecutive children/adolescents (2-20 years of age) with cognitive impairment and no verbal communication from four habilitation centres were admitted to the study. Each child's behaviour was observed by a parent or a caregiver and by a physiotherapist in two calm and two painful situations within the child's everyday life. The raters independently assessed and graded the child's behaviour during 5 min according to the translated Swedish version of the NCCPC-PV. The intrarater and interrater reliability were determined, and the construct validity was examined. The results from 202 assessments showed that the construct validity was good: children's behavioural signs differed significantly between situations of pain and situations of calm (p < 0.001). Repeated assessments showed poor agreement both within and between raters [intraclass correlation coefficient (ICC) 0.51-0.65]. The agreement for pain was good (ICC 0.83). The Swedish version of the NCCPC-PV can be used for pain assessment in children with cognitive impairments who lack verbal communication. Aspects of reliability need to be further analysed.

  20. Urogenital infections in women: can probiotics help?

    PubMed Central

    Reid, G; Bruce, A

    2003-01-01

    Urogenital infections not caused by sexual transmission, namely yeast vaginitis, bacterial vaginosis, and urinary tract infection remain a major medical problem in terms of the number of women afflicted each year. Although antimicrobial therapy is generally effective at eradicating these infections, there is still a high incidence of recurrence. The patient's quality of life is affected and many women become frustrated by the cycle of repeated antimicrobial agents whose effectiveness is diminishing due to increasing development of microbial resistance. There is good clinical evidence to show that the intestinal and urogenital microbial flora have a central role in maintaining both the health and wellbeing of humans. Furthermore, the use of "good bacteria" to replace or augment bacterial populations is gradually achieving scientific acceptance. This application is termed probiotics: "live micro-organisms which when administered in adequate amounts confer a health benefit on the host". The role of the intestinal, vaginal, and urethral flora and probiotics in urogenital health will be the focus of this review. PMID:12954951

  1. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection

    PubMed Central

    Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek

    2017-01-01

    A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1–100 μg/L for urine, 5–100 μg/L for saliva, and 3–100 μg/L for sweat samples with determination coefficients (R) > 0.992. Low detection limits (LODs) in the range of 1.8 μg/L, 5.1 μg/L, and 5.8 μg/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples. PMID:29348966

  2. Relationship between long working hours and depression: a 3-year longitudinal study of clerical workers.

    PubMed

    Amagasa, Takashi; Nakayama, Takeo

    2013-08-01

    To clarify how long working hours affect the likelihood of current and future depression. Using data from four repeated measurements collected from 218 clerical workers, four models associating work-related factors to the depressive mood scale were established. The final model was constructed after comparing and testing the goodness-of-fit index using structural equation modeling. Multiple logistic regression analysis was also performed. The final model showed the best fit (normed fit index = 0.908; goodness-of-fit index = 0.936; root-mean-square error of approximation = 0.018). Its standardized total effect indicated that long working hours affected depression at the time of evaluation and 1 to 3 years later. The odds ratio for depression risk was 14.7 in employees who were not long-hours overworked according to the initial survey but who were long-hours overworked according to the second survey. Long working hours increase current and future risks of depression.

  3. Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection.

    PubMed

    Jaszczak, Ewa; Ruman, Marek; Narkowicz, Sylwia; Namieśnik, Jacek; Polkowska, Żaneta

    2017-01-01

    A simple and accurate ion chromatography (IC) method with pulsed amperometric detection (PAD) was proposed for the determination of cyanide ion in urine, sweat, and saliva samples. The sample pretreatment relies on alkaline digestion and application of Dionex OnGuard II H cartridge. Under the optimized conditions, the method showed good linearity in the range of 1-100  μ g/L for urine, 5-100  μ g/L for saliva, and 3-100  μ g/L for sweat samples with determination coefficients ( R ) > 0.992. Low detection limits (LODs) in the range of 1.8  μ g/L, 5.1  μ g/L, and 5.8  μ g/L for urine, saliva, and sweat samples, respectively, and good repeatability (CV < 3%, n = 3) were obtained. The proposed method has been successfully applied to the analysis of human biological samples.

  4. Value of HIV patients with regular follow-up as in-house internal controls of flow cytometry measurement of lymphocyte subsets.

    PubMed

    de Carvalho Bittencourt, Marcelo; Kohler, Chantal; Henard, Sandrine; Rabaud, Christian; Béné, Marie C; Faure, Gilbert C

    2013-01-01

    Quality assessment in flow cytometry cannot obey the same rules as those applicable to the measurement of chemical analytes. However, regular follow-up of known patients may provide a robust in-house control of cell subsets evaluation. Sequential blood samples assessed for 32 HIV patients over several years and showing good stability were retrospectively assessed to establish coefficient of variations of the percentages of CD3+, CD4+, CD8+ cells, and CD4+ absolute counts (ACs). Mean relative standard variations for the whole cohort were of 0.04, 0.14, 0.08, and 0.18 for CD3%, CD4%, CD8%, and CD4 ACs, respectively. In-house follow-up of regularly checked compliant patients is a good alternative to traditional and costly repeatability and reproducibility studies for the validation of routine flow cytometry. © 2013 International Clinical Cytometry Society. Copyright © 2013 International Clinical Cytometry Society.

  5. Value of HIV patients with regular follow-up as in-house internal controls of flow cytometry measurement of lymphocyte subsets.

    PubMed

    de Carvalho Bittencourt, Marcelo; Kohler, Chantal; Henard, Sandrine; Rabaud, Christian; Béné, Marie C; Faure, Gilbert C

    2013-07-08

    Background. Quality assessment in flow cytometry cannot obey the same rules as those applicable to the measurement of chemical analytes. However, regular follow-up of known patients may provide a robust in-house control of cell subsets evaluation. Methods. Sequential blood samples assessed for 32 HIV patients over several years and showing good stability were retrospectively assessed to establish coefficient of variations of the percentages of CD3+, CD4+, CD8+ cells and CD4+ absolute counts. Results. Mean relative standard variations for the whole cohort were of 0.04, 0.14, 0.08 and 0.18 for CD3%, CD4% CD8% and CD4 absolute counts respectively. Discussion. In-house follow up of regularly checked compliant patients is a good alternative to traditional and costly repeatability and reproducibility studies for the validation of routine flow cytometry. © 2013 Clinical Cytometry Society. Copyright © 2013 Clinical Cytometry Society.

  6. Conducting interactive experiments online.

    PubMed

    Arechar, Antonio A; Gächter, Simon; Molleman, Lucas

    2018-01-01

    Online labor markets provide new opportunities for behavioral research, but conducting economic experiments online raises important methodological challenges. This particularly holds for interactive designs. In this paper, we provide a methodological discussion of the similarities and differences between interactive experiments conducted in the laboratory and online. To this end, we conduct a repeated public goods experiment with and without punishment using samples from the laboratory and the online platform Amazon Mechanical Turk. We chose to replicate this experiment because it is long and logistically complex. It therefore provides a good case study for discussing the methodological and practical challenges of online interactive experimentation. We find that basic behavioral patterns of cooperation and punishment in the laboratory are replicable online. The most important challenge of online interactive experiments is participant dropout. We discuss measures for reducing dropout and show that, for our case study, dropouts are exogenous to the experiment. We conclude that data quality for interactive experiments via the Internet is adequate and reliable, making online interactive experimentation a potentially valuable complement to laboratory studies.

  7. Accuracy of MRI skeletal age estimation for subjects 12-19. Potential use for subjects of unknown age.

    PubMed

    Serinelli, Serenella; Panebianco, Valeria; Martino, Milvia; Battisti, Sofia; Rodacki, Karina; Marinelli, Enrico; Zaccagna, Fulvio; Semelka, Richard C; Tomei, Ernesto

    2015-05-01

    In forensic practice, there is a growing need for accurate methods of age estimation, especially in the cases of young individuals of unknown age. Age can be estimated through somatic features that are universally considered associated with chronological age. Unfortunately, these features do not always coincide with the real chronological age: for these reasons that age determination is often very difficult. Our aim is to evaluate accuracy of skeletal age estimation using Tomei's MRI method in subjects between 12 and 19 years old for forensic purposes. Two investigators analyzed MRI images of the left hand and wrist of 77 male and 74 female caucasian subjects, without chronic diseases or developmental disorders, whose age ranged from 12 to 19 years. Skeletal maturation was determined by two operators, who analyzed all MRI images separately, in blinded fashion to the chronological age. Inter-rater agreement was measured with Pearson (R (2)) coefficient. One of the examiners repeated the evaluation after 6 months, and intraobserver variation was analyzed. Bland-Altman plots were used to determine mean differences between skeletal and chronological age. Inter-rater agreement Pearson coefficient showed a good linear correlation, respectively, 0.98 and 0.97 in males and females. Bland-Altman analysis demonstrated that the differences between chronological and skeletal age are not significant. Spearman's correlation coefficient showed good correlation between skeletal and chronological age both in females (R (2) = 0.96) and in males (R (2) = 0.94). Our results show that MRI skeletal age is a reproducible method and has good correlation with chronological age.

  8. Characterization of Al/crystallized Al-based metallic glass composites produced by repeated roll bonding process

    NASA Astrophysics Data System (ADS)

    Alizadeh, Morteza; Khoramkhorshid, Saba; Taghvaei, Amir Hossein; Gokuldoss, Prashanth Konda

    2017-07-01

    Devitrified Al84Gd6Ni7Co3 glassy particles have been used to reinforce Al-matrix composites through repeated roll bonding (RRB) process. Microstructural characterization of the produced composites after various rolling cycles was performed by scanning electron microscopy. Mechanical properties of the fabricated composites were evaluated by the tensile and microhardness tests. The results indicate that the RRB process is successful to produce composites with the negligible amount of flaws and porosity, and it is followed by homogeneous distribution of Al84Gd6Ni7Co3 particles in the Al matrix after nine rolling passes. Elongation of the composites improves significantly upon RRB cycles and the tensile strength and microhardness of them increase more than two times compared to unreinforced Al. According to fractography results, the enhanced mechanical properties are correlated with formation of excellent bonding at the interface of Al84Gd6Ni7Co3 particles and Al matrix. The theoretical values of composites hardness and yield strength calculated based on iso-strain model show a good agreement with respect to the experimental results.

  9. A comprehensive analysis of three Asiatic black bear mitochondrial genomes (subspecies ussuricus, formosanus and mupinensis), with emphasis on the complete mtDNA sequence of Ursus thibetanus ussuricus (Ursidae).

    PubMed

    Hwang, Dae-Sik; Ki, Jang-Seu; Jeong, Dong-Hyuk; Kim, Bo-Hyun; Lee, Bae-Keun; Han, Sang-Hoon; Lee, Jae-Seong

    2008-08-01

    In the present paper, we describe the mitochondrial genome sequence of the Asiatic black bear (Ursus thibetanus ussuricus) with particular emphasis on the control region (CR), and compared with mitochondrial genomes on molecular relationships among the bears. The mitochondrial genome sequence of U. thibetanus ussuricus was 16,700 bp in size with mostly conserved structures (e.g. 13 protein-coding, two rRNA genes, 22 tRNA genes). The CR consisted of several typical conserved domains such as F, E, D, and C boxes, and a conserved sequence block. Nucleotide sequences and the repeated motifs in the CR were different among the bear species, and their copy numbers were also variable according to populations, even within F1 generations of U. thibetanus ussuricus. Comparative analyses showed that the CR D1 region was highly informative for the discrimination of the bear family. These findings suggest that nucleotide sequences of both repeated motifs and CR D1 in the bear family are good markers for species discriminations.

  10. Stability of the Medial Olivocochlear Reflex as Measured by Distortion Product Otoacoustic Emissions

    PubMed Central

    Abdala, Carolina

    2015-01-01

    Purpose The purpose of this study was to assess the repeatability of a fine-resolution, distortion product otoacoustic emission (DPOAE)–based assay of the medial olivocochlear (MOC) reflex in normal-hearing adults. Method Data were collected during 36 test sessions from 4 normal-hearing adults to assess short-term stability and 5 normal-hearing adults to assess long-term stability. DPOAE level and phase measurements were recorded with and without contralateral acoustic stimulation. MOC reflex indices were computed by (a) noting contralateral acoustic stimulation-induced changes in DPOAE level (both absolute and normalized) at fine-structure peaks, (b) recording the effect as a vector difference, and (c) separating DPOAE components and considering a component-specific metric. Results Analyses indicated good repeatability of all indices of the MOC reflex in most frequency ranges. Short- and long-term repeatability were generally comparable. Indices normalized to a subject's own baseline fared best, showing strong short- and long-term stability across all frequency intervals. Conclusions These results suggest that fine-resolution DPOAE-based measures of the MOC reflex measured at strategic frequencies are stable, and natural variance from day-to-day or week-to-week durations is small enough to detect between-group differences and possibly to monitor intervention-related success. However, this is an empirical question that must be directly tested to confirm its utility. PMID:25320951

  11. Repeatability of DTI-based skeletal muscle fiber tracking

    PubMed Central

    Heemskerk, Anneriet M.; Sinha, Tuhin K.; Wilson, Kevin J.; Ding, Zhaohua; Damon, Bruce M.

    2015-01-01

    Diffusion tensor imaging (DTI)-based muscle fiber tracking enables the measurement of muscle architectural parameters, such as pennation angle (θ) and fiber tract length (Lft), throughout the entire muscle. Little is known, however, about the repeatability of either the muscle architectural measures or the underlying diffusion measures. Therefore, the goal of this study was to investigate the repeatability of DTI fiber tracking-based measurements and θ and Lft. Four DTI acquisitions were performed on two days that allowed for between acquisition, within day, and between day analyses. The eigenvalues and fractional anisotropy were calculated at the maximum cross-sectional area of, and fiber tracking was performed in, the tibialis anterior muscle of nine healthy subjects. The between acquisitions condition had the highest repeatability for the DTI indices and the architectural parameters. The overall inter class correlation coefficients (ICC’s) were greater than 0.6 for both θ and Lft and the repeatability coefficients were θ <10.2° and Lft < 50 mm. In conclusion, under the experimental and data analysis conditions used, the repeatability of the diffusion measures is very good and repeatability of the architectural measurements is acceptable. Therefore, this study demonstrates the feasibility for longitudinal studies of alterations in muscle architecture using DTI-based fiber tracking, under similar noise conditions and with similar diffusion characteristics. PMID:20099372

  12. A novel magnet based 3D printed marker wand as basis for repeated in-shoe multi segment foot analysis: a proof of concept.

    PubMed

    Eerdekens, Maarten; Staes, Filip; Pilkington, Thomas; Deschamps, Kevin

    2017-01-01

    Application of in-shoe multi-segment foot kinematic analyses currently faces a number of challenges, including: (i) the difficulty to apply regular markers onto the skin, (ii) the necessity for an adequate shoe which fits various foot morphologies and (iii) the need for adequate repeatability throughout a repeated measure condition. The aim of this study therefore was to design novel magnet based 3D printed markers for repeated in-shoe measurements while using accordingly adapted modified shoes for a specific multi-segment foot model. Multi-segment foot kinematics of ten participants were recorded and kinematics of hindfoot, midfoot and forefoot were calculated. Dynamic trials were conducted to check for intra and inter-session repeatability when combining novel markers and modified shoes in a repeated measures design. Intraclass correlation coefficients were calculated to determine reliability. Both repeatability and reliability were proven to be good to excellent with maximum joint angle deviations of 1.11° for intra-session variability and 1.29° for same-day inter-session variability respectively and ICC values of >0.91. The novel markers can be reliably used in future research settings using in-shoe multi-segment foot kinematic analyses with multiple shod conditions.

  13. Androgen receptor repeat length polymorphism associated with male-to-female transsexualism.

    PubMed

    Hare, Lauren; Bernard, Pascal; Sánchez, Francisco J; Baird, Paul N; Vilain, Eric; Kennedy, Trudy; Harley, Vincent R

    2009-01-01

    There is a likely genetic component to transsexualism, and genes involved in sex steroidogenesis are good candidates. We explored the specific hypothesis that male-to-female transsexualism is associated with gene variants responsible for undermasculinization and/or feminization. Specifically, we assessed the role of disease-associated repeat length polymorphisms in the androgen receptor (AR), estrogen receptor beta (ERbeta), and aromatase (CYP19) genes. Subject-control analysis included 112 male-to-female transsexuals and 258 non-transsexual males. Associations and interactions were investigated between CAG repeat length in the AR gene, CA repeat length in the ERbeta gene, and TTTA repeat length in the CYP19 gene and male-to-female transsexualism. A significant association was identified between transsexualism and the AR allele, with transsexuals having longer AR repeat lengths than non-transsexual male control subjects (p=.04). No associations for transsexualism were evident in repeat lengths for CYP19 or ERbeta genes. Individuals were then classified as short or long for each gene polymorphism on the basis of control median polymorphism lengths in order to further elucidate possible combined effects. No interaction associations between the three genes and transsexualism were identified. This study provides evidence that male gender identity might be partly mediated through the androgen receptor.

  14. Androgen Receptor Repeat Length Polymorphism Associated with Male-to-Female Transsexualism

    PubMed Central

    Hare, Lauren; Bernard, Pascal; Sánchez, Francisco J.; Baird, Paul N.; Vilain, Eric; Kennedy, Trudy; Harley, Vincent R.

    2012-01-01

    Background There is a likely genetic component to transsexualism, and genes involved in sex steroidogenesis are good candidates. We explored the specific hypothesis that male-to-female transsexualism is associated with gene variants responsible for undermasculinization and/or feminization. Specifically, we assessed the role of disease-associated repeat length polymorphisms in the androgen receptor (AR), estrogen receptor β (ERβ), and aromatase (CYP19) genes. Methods Subject-control analysis included 112 male-to-female transsexuals and 258 non-transsexual males. Associations and interactions were investigated between CAG repeat length in the AR gene, CA repeat length in the ERβ gene, and TTTA repeat length in the CYP19 gene and male-to-female transsexualism. Results A significant association was identified between transsexualism and the AR allele, with transsexuals having longer AR repeat lengths than non-transsexual male control subjects (p = .04). No associations for transsexualism were evident in repeat lengths for CYP19 or ERβ genes. Individuals were then classified as short or long for each gene polymorphism on the basis of control median polymorphism lengths in order to further elucidate possible combined effects. No interaction associations between the three genes and transsexualism were identified. Conclusions This study provides evidence that male gender identity might be partly mediated through the androgen receptor. PMID:18962445

  15. Linking automatic evaluation to mood and information processing style: consequences for experienced affect, impression formation, and stereotyping.

    PubMed

    Chartrand, Tanya L; van Baaren, Rick B; Bargh, John A

    2006-02-01

    According to the feelings-as-information account, a person's mood state signals to him or her the valence of the current environment (N. Schwarz & G. Clore, 1983). However, the ways in which the environment automatically influences mood in the first place remain to be explored. The authors propose that one mechanism by which the environment influences affect is automatic evaluation, the nonconscious evaluation of environmental stimuli as good or bad. A first experiment demonstrated that repeated brief exposure to positive or negative stimuli (which leads to automatic evaluation) induces a corresponding mood in participants. In 3 additional studies, the authors showed that automatic evaluation affects information processing style. Experiment 4 showed that participants' mood mediates the effect of valenced brief primes on information processing. ((c) 2006 APA, all rights reserved).

  16. Linking Automatic Evaluation to Mood and Information Processing Style: Consequences for Experienced Affect, Impression Formation, and Stereotyping

    PubMed Central

    Chartrand, Tanya L.; van Baaren, Rick B.; Bargh, John A.

    2009-01-01

    According to the feelings-as-information account, a person’s mood state signals to him or her the valence of the current environment (N. Schwarz & G. Clore, 1983). However, the ways in which the environment automatically influences mood in the first place remain to be explored. The authors propose that one mechanism by which the environment influences affect is automatic evaluation, the nonconscious evaluation of environmental stimuli as good or bad. A first experiment demonstrated that repeated brief exposure to positive or negative stimuli (which leads to automatic evaluation) induces a corresponding mood in participants. In 3 additional studies, the authors showed that automatic evaluation affects information processing style. Experiment 4 showed that participants’ mood mediates the effect of valenced brief primes on information processing. PMID:16478316

  17. Optically stimulated luminescence of natural NaCl mineral from Dead Sea exposed to gamma radiation.

    PubMed

    Roman-Lopez, J; Piña López, Y I; Cruz-Zaragoza, E; Marcazzó, J

    2018-08-01

    In this work, the continuous wave - optically stimulated luminescence (CW-OSL) emissions of natural salt minerals, collected from Dead Sea in summer of 2015, were studied. The CW-OSL dose response of natural salt showed a linear range between 0.5Gy and 10Gy of gamma radiation of 60 Co. Samples exposed at 3Gy exhibited good repeatability with a variation coefficient of 4.6%. The CW-OSL response as function of the preheating temperature (50-250°C) was analyzed. An increase of 15% of the CW-OSL response was observed in NaCl samples during storage period of 336h. The results showed that the natural Dead Sea salt minerals could be applied as natural dosimeter of gamma radiation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. An ultrafast X-ray scintillating detector made of ZnO(Ga)

    NASA Astrophysics Data System (ADS)

    Zhang, Qingmin; Yan, Jun; Deng, Bangjie; Zhang, Jingwen; Lv, Jinge; Wen, Xin; Gao, Keqing

    2017-12-01

    Owing to its ultrafast scintillation, quite high light yield, strong radiation resistance, and non-deliquescence, ZnO(Ga) is a highly promising choice for an ultrafast X-ray detector. Because of its high deposition rate, good production repeatability and strong adhesive force, reactive magnetron sputtering was used to produce a ZnO(Ga) crystal on a quartz glass substrate, after the production conditions were optimized. The fluorescence lifetime of the sample was 173 ps. An ultrafast X-ray scintillating detector, equipped with a fast microchannel plate (MCP) photomultiplier tube (PMT), was developed and the X-ray tests show a signal full width at half maximum (FWHM) of only 385.5 ps. Moreover, derivation from the previous measurement shows the ZnO(Ga) has an ultrafast time response (FWHM = 355.1 ps) and a high light yield (14740 photons/MeV).

  19. Measurement of trace nitrate concentrations in seawater by ion chromatography with valve switching

    NASA Astrophysics Data System (ADS)

    Du, Juan; Fa, Yun; Zheng, Yue; Li, Xuebing; Du, Fanglin; Yang, Haiyan

    2014-05-01

    An ion chromatographic method with a valve switching facility was developed to determine trace nitrate concentrations in seawater using two pumps, two different suppressors, and two columns. A carbohydrate membrane desalter was used to reduce the high concentrations of sodium salts in samples. In this method, trace nitrate was eluted from the concentrator column to the analytical columns, while the matrix fl owed to waste. Neither chemical pre-treatment nor sample dilution was required. In the optimized separation conditions, the method showed good linearity ( R >0.99) in the 0.05 and 50 mg/L concentration range, and satisfactory repeatability (RSD<5%, n =6). The limit of detection for nitrate was 0.02 mg/L. Results showed that the valve switching system was suitable and practical for the determination of trace nitrate in seawater.

  20. Micro-structured femtosecond laser assisted FBG hydrogen sensor.

    PubMed

    Karanja, Joseph Muna; Dai, Yutang; Zhou, Xian; Liu, Bin; Yang, Minghong

    2015-11-30

    We discuss hydrogen sensors based on fiber Bragg gratings (FBGs) micro-machined by femtosecond laser to form microgrooves and sputtered with Pd/Ag composite film. The atomic ratio of the two metals is controlled at Pd:Ag = 3:1. At room temperature, the hydrogen sensitivity of the sensor probe micro-machined by 75 mW laser power and sputtered with 520 nm of Pd/Ag film is 16.5 pm/%H. Comparably, the standard FBG hydrogen sensitivity becomes 2.5 pm/%H towards the same 4% hydrogen concentration. At an ambient temperature of 35°C, the processed sensor head has a dramatic rise in hydrogen sensitivity. Besides, the sensor shows good response and repeatability during hydrogen concentration test.

  1. Feasibility of atmospheric pressure desorption/ionization on silicon mass spectrometry in analysis of drugs.

    PubMed

    Huikko, K; Ostman, P; Sauber, C; Mandel, F; Grigoras, K; Franssila, S; Kotiaho, T; Kostiainen, R

    2003-01-01

    The feasibility of atmospheric pressure desorption/ionization on silicon mass spectrometry (AP-DIOS-MS) for drug analysis was investigated. It was observed that only compounds with relative high proton affinity are efficiently ionized under AP-DIOS conditions. The limits of detection (LODs) achieved in MS mode with midazolam, propranolol, and angiotensin II were 80 fmol, 20 pmol, and 1 pmol, respectively. In MS/MS mode the LODs for midazolam and propranolol were 10 fmol and 5 pmol, respectively. The good linearity (r(2) > 0.991), linear dynamic range of 3 orders of magnitude, and reasonable repeatability showed that the method is suitable for quantitative analysis. Copyright 2003 John Wiley & Sons, Ltd.

  2. UV-photodetector based on NiO/diamond film

    NASA Astrophysics Data System (ADS)

    Chang, Xiaohui; Wang, Yan-Feng; Zhang, Xiaofan; Liu, Zhangcheng; Fu, Jiao; Fan, Shuwei; Bu, Renan; Zhang, Jingwen; Wang, Wei; Wang, Hong-Xing; Wang, Jingjing

    2018-01-01

    In this study, a NiO/diamond UV-photodetector has been fabricated and investigated. A single crystal diamond (SCD) layer was grown on a high-pressure-high-temperature Ib-type diamond substrate by using a microwave plasma chemical vapor deposition system. NiO films were deposited directly by the reactive magnetron sputtering technique in a mixture gas of oxygen and argon onto the SCD layer. Gold films were patterned on NiO films as electrodes to form the metal-semiconductor-metal UV-photodetector which shows good repeatability and a 2 orders of magnitude UV/visible rejection ratio. Also, the NiO/diamond photodetector has a higher responsivity and a wider response range in contrast to a diamond photodetector.

  3. High-speed and low-power repeater for VLSI interconnects

    NASA Astrophysics Data System (ADS)

    Karthikeyan, A.; Mallick, P. S.

    2017-10-01

    This paper proposes a repeater for boosting the speed of interconnects with low power dissipation. We have designed and implemented at 45 and 32 nm technology nodes. Delay and power dissipation performances are analyzed for various voltage levels at these technology nodes using Spice simulations. A significant reduction in delay and power dissipation are observed compared to a conventional repeater. The results show that the proposed high-speed low-power repeater has a reduced delay for higher load capacitance. The proposed repeater is also compared with LPTG CMOS repeater, and the results shows that the proposed repeater has reduced delay. The proposed repeater can be suitable for high-speed global interconnects and has the capacity to drive large loads.

  4. Absence of chronic traumatic encephalopathy in retired football players with multiple concussions and neurological symptomatology

    PubMed Central

    Hazrati, Lili-Naz; Tartaglia, Maria C.; Diamandis, Phedias; Davis, Karen D.; Green, Robin E.; Wennberg, Richard; Wong, Janice C.; Ezerins, Leo; Tator, Charles H.

    2013-01-01

    Background: Chronic traumatic encephalopathy (CTE) is the term coined for the neurodegenerative disease often suspected in athletes with histories of repeated concussion and progressive dementia. Histologically, CTE is defined as a tauopathy with a distribution of tau-positive neurofibrillary tangles (NFTs) that is distinct from other tauopathies, and usually shows an absence of beta-amyloid deposits, in contrast to Alzheimer's disease (AD). Although the connection between repeated concussions and CTE-type neurodegeneration has been recently proposed, this causal relationship has not yet been firmly established. Also, the prevalence of CTE among athletes with multiple concussions is unknown. Methods: We performed a consecutive case series brain autopsy study on six retired professional football players from the Canadian Football League (CFL) with histories of multiple concussions and significant neurological decline. Results: All participants had progressive neurocognitive decline prior to death; however, only 3 cases had post-mortem neuropathological findings consistent with CTE. The other 3 participants had pathological diagnoses of AD, amyotrophic lateral sclerosis (ALS), and Parkinson's disease (PD). Moreover, the CTE cases showed co-morbid pathology of cancer, vascular disease, and AD. Discussion: Our case studies highlight that not all athletes with history of repeated concussions and neurological symptomology present neuropathological changes of CTE. These preliminary findings support the need for further research into the link between concussion and CTE as well as the need to expand the research to other possible causes of taupathy in athletes. They point to a critical need for prospective studies with good sampling methods to allow us to understand the relationship between multiple concussions and the development of CTE. PMID:23745112

  5. Use of sediment source fingerprinting to assess the role of subsurface erosion in the supply of fine sediment in a degraded catchment in the Eastern Cape, South Africa.

    PubMed

    Manjoro, Munyaradzi; Rowntree, Kate; Kakembo, Vincent; Foster, Ian; Collins, Adrian L

    2017-06-01

    Sediment source fingerprinting has been successfully deployed to provide information on the surface and subsurface sources of sediment in many catchments around the world. However, there is still scope to re-examine some of the major assumptions of the technique with reference to the number of fingerprint properties used in the model, the number of model iterations and the potential uncertainties of using more than one sediment core collected from the same floodplain sink. We investigated the role of subsurface erosion in the supply of fine sediment to two sediment cores collected from a floodplain in a small degraded catchment in the Eastern Cape, South Africa. The results showed that increasing the number of individual fingerprint properties in the composite signature did not improve the model goodness-of-fit. This is still a much debated issue in sediment source fingerprinting. To test the goodness-of-fit further, the number of model repeat iterations was increased from 5000 to 30,000. However, this did not reduce uncertainty ranges in modelled source proportions nor improve the model goodness-of-fit. The estimated sediment source contributions were not consistent with the available published data on erosion processes in the study catchment. The temporal pattern of sediment source contributions predicted for the two sediment cores was very different despite the cores being collected in close proximity from the same floodplain. This highlights some of the potential limitations associated with using floodplain cores to reconstruct catchment erosion processes and associated sediment source contributions. For the source tracing approach in general, the findings here suggest the need for further investigations into uncertainties related to the number of fingerprint properties included in un-mixing models. The findings support the current widespread use of ≤5000 model repeat iterations for estimating the key sources of sediment samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. [Determination of heavy metals for RoHS compliance by ICP-OES spectrometry coupled with microwave extraction system].

    PubMed

    Hua, Li; Wu, Yi-Ping; An, Bing; Lai, Xiao-Wei

    2008-11-01

    The harm of heavy metals contained in electronic and electrical equipment (EEE) on environment is of high concern by human. Aiming to handle the great challenge of RoHS compliance, the determinations of trace or ultratrace chromium (Cr), cadmium (Cd), mercury (Hg) and lead (Pb) by inductively coupled plasma optical emission spectrometry (ICP-OES) was performed in the present paper, wherein, microwave extraction technology was used to prepare the sample solutions. In addition, the precision, recovery, repeatability and interference issues of this method were also discussed. The results exhibited that using the microwave extraction system to prepare samples is more quick, lossless, contamination-free in comparison with the conventional extraction methods such as dry ashing, wet-oven extraction etc. By analyzing the recoveries of these four heavy metals over different working time and wavelengths, the good recovery range between 85% and 115% showed that there was only tiny loss or contamination during the process of microwave extraction, sample introduction and ICP detection. Repeatability experiments proved that ICP plasma had a good stability during the working time and the matrix effect was small. Interference was a problem troublesome for atomic absorption spectrometry (AAS), however, the techniques of standard additions or inter-element correction (IEC) method can effectively eliminated the interferences of Ni, As, Fe etc. with the Cd determination. By employing the multi-wavelengths and two correction point methods, the issues of background curve sloping shift and spectra overlap were successfully overcome. Besides, for the determinations of trace heavy metal elements, the relative standard deviation (RSD) was less than 3% and the detection limits were less than 1 microg x L(-10 (3sigma, n = 5) for samples, standard solutions, and standard additions, which proved that ICP-OES has a good precision and high reliability. This provided a reliable technique support for electronic and electrical (EE) industries to comply with RoHS directive.

  7. Validity and reliability of a novel measure of activity performance and participation.

    PubMed

    Murgatroyd, Phil; Karimi, Leila

    2016-01-01

    To develop and evaluate an innovative clinician-rated measure, which produces global numerical ratings of activity performance and participation. Repeated measures study with 48 community-dwelling participants investigating clinical sensibility, comprehensiveness, practicality, inter-rater reliability, responsiveness, sensitivity and concurrent validity with Barthel Index. Important clinimetric characteristics including comprehensiveness and ease of use were rated >8/10 by clinicians. Inter-rater reliability was excellent on the summary scores (intraclass correlation of 0.95-0.98). There was good evidence that the new outcome measure distinguished between known high and low functional scoring groups, including both responsiveness to change and sensitivity at the same time point in numerous tests. Concurrent validity with the Barthel Index was fair to high (Spearman Rank Order Correlation 0.32-0.85, p > 0.05). The new measure's summary scores were nearly twice as responsive to change compared with the Barthel Index. Other more detailed data could also be generated by the new measure. The Activity Performance Measure is an innovative outcome instrument that showed good clinimetric qualities in this initial study. Some of the results were strong, given the sample size, and further trial and evaluation is appropriate. Implications for Rehabilitation The Activity Performance Measure is an innovative outcome measure covering activity performance and participation. In an initial evaluation, it showed good clinimetric qualities including responsiveness to change, sensitivity, practicality, clinical sensibility, item coverage, inter-rater reliability and concurrent validity with the Barthel Index. Further trial and evaluation is appropriate.

  8. Is Forced Swimming Immobility a Good Endpoint for Modeling Negative Symptoms of Schizophrenia? - Study of Sub-Anesthetic Ketamine Repeated Administration Effects.

    PubMed

    Neves, Gilda; Borsoi, Milene; Antonio, Camila B; Pranke, Mariana A; Betti, Andresa H; Rates, Stela M K

    2017-01-01

    Immobility time in the forced swimming has been described as analogous to emotional blunting or apathy and has been used for characterizing schizophrenia animal models. Several clinical studies support the use of NMDA receptor antagonists to model schizophrenia in rodents. Some works describe the effects of ketamine on immobility behavior but there is variability in the experimental design used leading to controversial results. In this study, we evaluated the effects of repeated administration of ketamine sub-anesthetic doses in forced swimming, locomotion in response to novelty and novel object recognition, aiming a broader evaluation of the usefulness of this experimental approach for modeling schizophrenia in mice. Ketamine (30 mg/kg/day i.p. for 14 days) induced a not persistent decrease in immobility time, detected 24h but not 72h after treatment. This same administration protocol induced a deficit in novel object recognition. No change was observed in mice locomotion. Our results confirm that repeated administration of sub-anesthetic doses of ketamine is useful in modeling schizophrenia-related behavioral changes in mice. However, the immobility time during forced swimming does not seem to be a good endpoint to evaluate the modeling of negative symptoms in NMDAR antagonist animal models of schizophrenia.

  9. Design and fabrication of a polyimide-based microelectrode array: application in neural recording and repeatable electrolytic lesion in rat brain.

    PubMed

    Chen, You-Yin; Lai, Hsin-Yi; Lin, Sheng-Huang; Cho, Chien-Wen; Chao, Wen-Hung; Liao, Chia-Hsin; Tsang, Siny; Chen, Yi-Fan; Lin, Si-Yue

    2009-08-30

    The design and testing of a new microelectrode array, the NCTU (National Chiao Tung University) probe, was presented. Evaluation results showed it has good biocompatibility, high signal-to-noise ratio (SNR: the root mean square of background noise to the average peak-to-peak amplitude of spikes) during chronic neural recordings, and high reusability for electrolytic lesions. The probe was a flexible, polyimide-based microelectrode array with a long shaft (14.9 mm in length) and 16 electrodes (5 microm-thick and 16 microm in radius); its performance in chronic in vivo recordings was examined in rodents. To improve the precision of implantation, a metallic, impact-resistant layer was sandwiched between the polyimide layers to strengthen the probe. The three-dimensional (3D) structure of electrodes fabricated by electroplating produced rough textures that increased the effective surface area. The in vitro impedance of electrodes on the NCTU probe was 2.4+/-0.52 MOmega at 1 kHz. In addition, post-surgical neural recordings of implanted NCTU probes were conducted for up to 40 days in awake, normally behaving rats. The electrodes on the NCTU probe functioned well and had a high SNR (range: 4-5) with reliable in vivo impedance (<0.7 MOmega). The electrodes were also robust enough to functionally record events, even after the anodal current (30 microA, 10s) was repeatedly applied for 60 times. With good biocompatibility, high and stable SNR for chronic recording, and high tolerance for electrolytic lesion, the NCTU probe would serve as a useful device in future neuroscience research.

  10. Polymeric ionic liquid based on magnetic materials fabricated through layer-by-layer assembly as adsorbents for extraction of pesticides.

    PubMed

    He, Lijun; Cui, Wenhang; Wang, Yali; Zhao, Wenjie; Xiang, Guoqiang; Jiang, Xiuming; Mao, Pu; He, Juan; Zhang, Shusheng

    2017-11-03

    In this study, layer-by-layer assembly of polyelectrolyte multilayer films on magnetic silica provided a convenient and controllable way to prepare polymeric ionic liquid-based magnetic adsorbents. The resulting particles were characterized by Fourier transform infrared spectroscopy, X-ray diffraction, transmission electron microscopy, and magnetic measurements. The data showed that the magnetic particles had more homogeneous spherical shapes with higher saturation magnetization when compared to those obtained by free radical polymerization method. This facilitated the convenient collection of magnetic particles, with higher extraction repeatability. The extraction performance of the multilayer polymeric ionic liquid-based adsorbents was evaluated by magnetic solid-phase extraction of four pesticides including quinalphos, fenthion, phoxim, and chlorpropham. The data suggested that the extraction efficiency depended on the number of layers in the film. The parameters affecting the extraction efficiency were optimized, and good linearity ranging from 2 to 250μgL -1 was obtained with correlation coefficients of 0.9994-0.9998. Moreover, the proposed method presented low limit of detection (0.5μgL -1 , S/N=3) and limit of quantification (1.5μgL -1 , S/N=10), and good repeatability expressed by the relative standard deviation (2.0%-4.6%, n=5). The extraction recoveries of four pesticides were found to range from 58.9% to 85.8%. The reliability of the proposed method was demonstrated by analyzing environmental water samples, and the results revealed satisfactory spiked recovery, relative standard deviation, and selectivity. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Efficacy of delayed treatment of China-made Peramivir with repeated intravenous injections in a mouse influenza model: from clinical experience to basal experiment.

    PubMed

    Li, Zhengtu; Li, Runfeng; Li, Jing; Xie, Hui; Hao, Yanbing; Du, Qiuling; Chen, Tingting; Li, Yimin; Chen, Rongchang; Yang, Zifeng; Zhong, Nanshan

    2016-07-08

    China-made Peramivir, an anti-influenza neuraminidase inhibitor drug, is manufactured and widely used in China. Although effective if initiated within 48 h of the onset of symptoms, yet we observed that this drug shows an inconclusive efficacy if treatment is delayed in clinical. Thus we evaluated the efficacy of delayed treatment of China-made Peramivir in a mouse model. The mouse model of influenza infection was made and Peramivir was administered intravenously for 5 days following infection, and weight loss, lung index, viral shedding and survival rates were monitored. Peramivir (60 mg/kg · d, repeated intravenous injections, quaque die (QD) × 5 days) enhanced survival rate and suppressed weight loss when treatment was initiated 24, 36, 48, or even 60 h post-infection (p.i.) (p < 0.01), compared with the virus-untreated group, and efficacy was abolished at 72 h p.i.. However the efficacy of delayed treatment was dose dependent, with the highest dose (90 mg/kg · d) even showing efficacy at 72 h p.i.. Furthermore, Peramivir (60 mg/kg · d, repeated intravenous injections, QD × 5 days) also reduced the lung virus titer 24 and 36 h p.i. on day 5, and even at 48 and 60 h p.i. on day 7 after infection, and the lung index was also improved. What is interesting that the concentration of the drug was maintained in blood after infected. Delayed treatment with China-made Peramivir can reduce the severity of influenza disease, accelerate viral clearance and enhance the survival rate. This drug therefore shows good efficacy and is a promising candidate to control the influenza epidemic in China.

  12. DRD4 long allele carriers show heightened attention to high-priority items relative to low-priority items.

    PubMed

    Gorlick, Marissa A; Worthy, Darrell A; Knopik, Valerie S; McGeary, John E; Beevers, Christopher G; Maddox, W Todd

    2015-03-01

    Humans with seven or more repeats in exon III of the DRD4 gene (long DRD4 carriers) sometimes demonstrate impaired attention, as seen in attention-deficit hyperactivity disorder, and at other times demonstrate heightened attention, as seen in addictive behavior. Although the clinical effects of DRD4 are the focus of much work, this gene may not necessarily serve as a "risk" gene for attentional deficits, but as a plasticity gene where attention is heightened for priority items in the environment and impaired for minor items. Here we examine the role of DRD4 in two tasks that benefit from selective attention to high-priority information. We examine a category learning task where performance is supported by focusing on features and updating verbal rules. Here, selective attention to the most salient features is associated with good performance. In addition, we examine the Operation Span (OSPAN) task, a working memory capacity task that relies on selective attention to update and maintain items in memory while also performing a secondary task. Long DRD4 carriers show superior performance relative to short DRD4 homozygotes (six or less tandem repeats) in both the category learning and OSPAN tasks. These results suggest that DRD4 may serve as a "plasticity" gene where individuals with the long allele show heightened selective attention to high-priority items in the environment, which can be beneficial in the appropriate context.

  13. Comparison of cerebral tissue oxygenation values in full term and preterm newborns by the simultaneous use of two near-infrared spectroscopy devices: an absolute and a relative trending oximeter

    NASA Astrophysics Data System (ADS)

    Szczapa, Tomasz; Karpiński, Łukasz; Moczko, Jerzy; Weindling, Michael; Kornacka, Alicja; Wróblewska, Katarzyna; Adamczak, Aleksandra; Jopek, Aleksandra; Chojnacka, Karolina; Gadzinowski, Janusz

    2013-08-01

    The aim of this study is to compare a two-wavelength light emitting diode-based tissue oximeter (INVOS), which is designed to show trends in tissue oxygenation, with a four-wavelength laser-based oximeter (FORE-SIGHT), designed to deliver absolute values of tissue oxygenation. Simultaneous values of cerebral tissue oxygenation (StO2) are measured using both devices in 15 term and 15 preterm clinically stable newborns on the first and third day of life. Values are recorded simultaneously in two periods between which oximeter sensor positions are switched to the contralateral side. Agreement between StO2 values before and after the change of sensor position is analyzed. We find that mean cerebral StO2 values are similar between devices for term and preterm babies, but INVOS shows StO2 values spread over a wider range, with wider standard deviations than shown by the FORE-SIGHT. There is relatively good agreement with a bias up to 3.5% and limits of agreement up to 11.8%. Measurements from each side of the forehead show better repeatability for the FORE-SIGHT monitor. We conclude that performance of the two devices is probably acceptable for clinical purposes. Both performed sufficiently well, but the use of FORE-SIGHT may be associated with tighter range and better repeatability of data.

  14. Reinforcement Learning Explains Conditional Cooperation and Its Moody Cousin.

    PubMed

    Ezaki, Takahiro; Horita, Yutaka; Takezawa, Masanori; Masuda, Naoki

    2016-07-01

    Direct reciprocity, or repeated interaction, is a main mechanism to sustain cooperation under social dilemmas involving two individuals. For larger groups and networks, which are probably more relevant to understanding and engineering our society, experiments employing repeated multiplayer social dilemma games have suggested that humans often show conditional cooperation behavior and its moody variant. Mechanisms underlying these behaviors largely remain unclear. Here we provide a proximate account for this behavior by showing that individuals adopting a type of reinforcement learning, called aspiration learning, phenomenologically behave as conditional cooperator. By definition, individuals are satisfied if and only if the obtained payoff is larger than a fixed aspiration level. They reinforce actions that have resulted in satisfactory outcomes and anti-reinforce those yielding unsatisfactory outcomes. The results obtained in the present study are general in that they explain extant experimental results obtained for both so-called moody and non-moody conditional cooperation, prisoner's dilemma and public goods games, and well-mixed groups and networks. Different from the previous theory, individuals are assumed to have no access to information about what other individuals are doing such that they cannot explicitly use conditional cooperation rules. In this sense, myopic aspiration learning in which the unconditional propensity of cooperation is modulated in every discrete time step explains conditional behavior of humans. Aspiration learners showing (moody) conditional cooperation obeyed a noisy GRIM-like strategy. This is different from the Pavlov, a reinforcement learning strategy promoting mutual cooperation in two-player situations.

  15. DRD4 Long Allele Carriers Show Heightened Attention to High-Priority Items Relative to Low-Priority Items

    PubMed Central

    Gorlick, Marissa A.; Worthy, Darrell A.; Knopik, Valerie S.; McGeary, John E.; Beevers, Christopher G.; Maddox, W. Todd

    2014-01-01

    Humans with 7 or more repeats in exon III of the DRD4 gene (long DRD4 carriers) sometimes demonstrate impaired attention, as seen in ADHD, and at other times demonstrate heightened attention, as seen in addictive behavior. Though the clinical effects of DRD4 are the focus of much work, this gene may not necessarily serve as a ‘risk’ gene for attentional deficits, but as a plasticity gene where attention is heightened for priority items in the environment and impaired for minor items. Here we examine the role of DRD4 in two tasks that benefit from selective attention to high-priority information. We examine a category learning task where performance is supported by focusing on features and updating verbal rules. Here selective attention to the most salient features is associated with good performance. In addition, we examine the Operation Span Task (OSPAN), a working memory capacity task that relies on selective attention to update and maintain items in memory while also performing a secondary task. Long DRD4 carriers show superior performance relative to short DRD4 homozygotes (six or less tandem repeats) in both the category learning and OSPAN tasks. These results suggest that DRD4 may serve as a ‘plasticity’ gene where individuals with the long allele show heightened selective attention to high-priority items in the environment, which can be beneficial in the appropriate context. PMID:25244120

  16. Repeating and non-repeating fast radio bursts from binary neutron star mergers

    NASA Astrophysics Data System (ADS)

    Yamasaki, Shotaro; Totani, Tomonori; Kiuchi, Kenta

    2018-04-01

    Most fast radio bursts (FRB) do not show evidence of repetition, and such non-repeating FRBs may be produced at the time of a merger of binary neutron stars (BNS), provided that the BNS merger rate is close to the high end of the currently possible range. However, the merger environment is polluted by dynamical ejecta, which may prohibit the radio signal from propagating. We examine this by using a general-relativistic simulation of a BNS merger, and show that the ejecta appears about 1 ms after the rotation speed of the merged star becomes the maximum. Therefore there is a time window in which an FRB signal can reach outside, and the short duration of non-repeating FRBs can be explained by screening after ejecta formation. A fraction of BNS mergers may leave a rapidly rotating and stable neutron star, and such objects may be the origin of repeating FRBs like FRB 121102. We show that a merger remnant would appear as a repeating FRB on a time scale of ˜1-10 yr, and expected properties are consistent with the observations of FRB 121102. We construct an FRB rate evolution model that includes these two populations of repeating and non-repeating FRBs from BNS mergers, and show that the detection rate of repeating FRBs relative to non-repeating ones rapidly increases with improving search sensitivity. This may explain why only the repeating FRB 121102 was discovered by the most sensitive FRB search with Arecibo. Several predictions are made, including the appearance of a repeating FRB 1-10 yr after a BNS merger that is localized by gravitational waves and subsequent electromagnetic radiation.

  17. Repeating and non-repeating fast radio bursts from binary neutron star mergers

    NASA Astrophysics Data System (ADS)

    Yamasaki, Shotaro; Totani, Tomonori; Kiuchi, Kenta

    2018-06-01

    Most fast radio bursts (FRB) do not show evidence of repetition, and such non-repeating FRBs may be produced at the time of a merger of binary neutron stars (BNS), provided that the BNS merger rate is close to the high end of the currently possible range. However, the merger environment is polluted by dynamical ejecta, which may prohibit the radio signal from propagating. We examine this by using a general-relativistic simulation of a BNS merger, and show that the ejecta appears about 1 ms after the rotation speed of the merged star becomes the maximum. Therefore there is a time window in which an FRB signal can reach outside, and the short duration of non-repeating FRBs can be explained by screening after ejecta formation. A fraction of BNS mergers may leave a rapidly rotating and stable neutron star, and such objects may be the origin of repeating FRBs like FRB 121102. We show that a merger remnant would appear as a repeating FRB on a time scale of ˜1-10 yr, and expected properties are consistent with the observations of FRB 121102. We construct an FRB rate evolution model that includes these two populations of repeating and non-repeating FRBs from BNS mergers, and show that the detection rate of repeating FRBs relative to non-repeating ones rapidly increases with improving search sensitivity. This may explain why only the repeating FRB 121102 was discovered by the most sensitive FRB search with Arecibo. Several predictions are made, including the appearance of a repeating FRB 1-10 yr after a BNS merger that is localized by gravitational waves and subsequent electromagnetic radiation.

  18. SU-E-T-287: Dose Verification On the Variation of Target Volume and Organ at Risk in Preradiation Chemotherapy IMRT for Nasopharyngeal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, X; Kong, L; Wang, J

    2015-06-15

    Purpose: To quantify the target volume and organ at risk of nasopharyngeal carcinoma (NPC) patients with preradiation chemotherapy based on CT scanned during intensity-modulated radiotherapy (IMRT), and recalculate the dose distribution. Methods: Seven patients with NPC and preradiation chemotherapy, treated with IMRT (35 to 37 fractions) were reviewed. Repeat CT scanning was required to all of the patients during the radiotherapy, and the number of repeat CTs varies from 2 to 6. The plan CT and repeat CT were generated by different CT scanner. To ensure crespectively on the same IMPT plan. The real dose distribution was calculated by deformablemore » registration and weighted method in Raystation (v 4.5.1). The fraction of each dose is based on radiotherapy record. The volumetric and dose differences among these images were calculated for nascIpharyngeal tumor and retro-pharyngeal lymph nodes (GTV-NX), neck lymph nodes(GTV-ND), and parotid glands. Results: The volume variation in GTV-NX from CT1 to CT2 was 1.15±3.79%, and in GTV-LN −0.23±4.93%. The volume variation in left parotid from CT1 to CT2 was −6.79±11.91%, and in right parotid −3.92±8.80%. In patient 2, the left parotid volume were decreased remarkably, as a Result, the V30 and V40 of it were increased as well. Conclusion: The target volume of patients with NPC varied lightly during IMRT. It shows that preradiation chemotherapy can control the target volume variation and perform a good dose repeatability. Also, the decreasing volume of parotid in some patient might increase the dose of it, which might course potential complications.« less

  19. Affect-regulated exercise intensity: does training at an intensity that feels 'good' improve physical health?

    PubMed

    Parfitt, Gaynor; Alrumh, Amnah; Rowlands, Alex V

    2012-11-01

    Affect-regulated exercise to feel 'good' can be used to control exercise intensity amongst both active and sedentary individuals and should support exercise adherence. It is not known, however, whether affect-regulated exercise training can lead to physical health gains. The aim of this study was to examine if affect-regulated exercise to feel 'good' leads to improved fitness over the course of an 8-week training programme. A repeated measures design (pretest-posttest) with independent groups (training and control). 20 sedentary females completed a submaximal graded exercise test and were then allocated to either a training group or control group. The training group completed two supervised sessions and one unsupervised session per week for 8 weeks. Exercise intensity was affect-regulated to feel 'good'. Following the 8 weeks of training, both groups completed a second submaximal graded exercise test. Repeated measures analyses of variance indicated a significant increase in the time to reach ventilatory threshold in the training group (318 ± 23.7s) compared to control (248 ± 16.9s). Overall compliance to training was high (>92%). Participants in the training group exercised at intensities that would be classified as being in the lower range of the recommended guidelines (≈ 50% V˙O(2) max) for cardiovascular health. Affect-regulated exercise to feel 'good' can be used in a training programme to regulate exercise intensity. This approach led to a 19% increase in time to reach ventilatory threshold, which is indicative of improved fitness. Copyright © 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  20. First GPS baseline results from the North Andes

    NASA Technical Reports Server (NTRS)

    Kellogg, James N.; Freymueller, Jeffrey T.; Dixon, Timothy H.; Neilan, Ruth E.; Ropain, Clemente

    1990-01-01

    The CASA Uno GPS experiment (January-February 1988) has provided the first epoch baseline measurements for the study of plate motions and crustal deformation in and around the North Andes. Two dimensional horizontal baseline repeatabilities are as good as 5 parts in 10 to the 8th for short baselines (100-1000 km), and better than 3 parts in 10 to the 8th for long baselines (greater than 1000 km). Vertical repeatabilities are typically 4-6 cm, with a weak dependence on baseline length. The expected rate of plate convergence across the Colombia Trench is 6-8cm/yr, which should be detectable by the repeat experiment planned for 1991. Expected deformation rates within the North Andes are of the order of 1 cm/yr, which may be detectable with the 1991 experiment.

  1. Large membrane deflection via capillary force actuation

    NASA Astrophysics Data System (ADS)

    Barth, Christina A.; Hu, Xiaoyu; Mibus, Marcel A.; Reed, Michael L.; Knospe, Carl R.

    2018-06-01

    Experimental results from six prototype devices demonstrate that pressure changes induced in a liquid bridge via electrowetting can generate large deflections (20–75 µm) of an elastomeric membrane similar to those used in lab-on-a-chip microfluidic devices. In all cases deflections are obtained with a low voltage (20 V) and very small power consumption (<1 µW). The effects of variations in the bridge size and membrane dimensions on measured displacements are examined. Theoretical predictions are in good agreement with the measured displacements in those cases where the liquid contact angles could be measured within the devices during electrowetting. Contact angle hysteresis and charge injection into the dielectric layers limited the repeatability of deflection behavior during repeated cycling. Approaches for achieving greater deflections and improved repeatability are discussed.

  2. Repeated-batch fermentations of xylose and glucose-xylose mixtures using a respiration-deficient Saccharomyces cerevisiae engineered for xylose metabolism.

    PubMed

    Kim, Soo Rin; Lee, Ki-Sung; Choi, Jin-Ho; Ha, Suk-Jin; Kweon, Dae-Hyuk; Seo, Jin-Ho; Jin, Yong-Su

    2010-11-01

    Xylose-fermenting Saccharomyces strains are needed for commercialization of ethanol production from lignocellulosic biomass. Engineered Saccharomyces cerevisiae strains expressing XYL1, XYL2 and XYL3 from Pichia stipitis, however, utilize xylose in an oxidative manner, which results in significantly lower ethanol yields from xylose as compared to glucose. As such, we hypothesized that reconfiguration of xylose metabolism from oxidative into fermentative manner might lead to efficient ethanol production from xylose. To this end, we generated a respiration-deficient (RD) mutant in order to enforce engineered S. cerevisiae to utilize xylose only through fermentative metabolic routes. Three different repeated-batch fermentations were performed to characterize characteristics of the respiration-deficient mutant. When fermenting glucose as a sole carbon source, the RD mutant exhibited near theoretical ethanol yields (0.46 g g(-1)) during repeated-batch fermentations by recycling the cells. As the repeated-batch fermentation progressed, the volumetric ethanol productivity increased (from 7.5 to 8.3 g L(-1)h(-1)) because of the increased biomass from previous cultures. On the contrary, the mutant showed decreasing volumetric ethanol productivities during the repeated-batch fermentations using xylose as sole carbon source (from 0.4 to 0.3 g L(-1)h(-1)). The mutant did not grow on xylose and lost fermenting ability gradually, indicating that the RD mutant cannot maintain a good fermenting ability on xylose as a sole carbon source. However, the RD mutant was capable of fermenting a mixture of glucose and xylose with stable yields (0.35 g g(-1)) and productivities (0.52 g L(-1)h(-1)) during the repeated-batch fermentation. In addition, ethanol yields from xylose during the mixed sugar fermentation (0.30 g g(-1)) were higher than ethanol yields from xylose as a sole carbon source (0.21 g g(-1)). These results suggest that a strategy for increasing ethanol yield through respiration-deficiency can be applied for the fermentation of lignocellulosic hydrolyzates containing glucose and xylose. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. A novel five-wire micro anemometer with 3D directionality for low speed air flow detection and acoustic particle velocity detecting capability

    NASA Astrophysics Data System (ADS)

    Li, Zhe; Chang, Wenhan; Gao, Chengchen; Hao, Yilong

    2018-04-01

    In this paper, a novel five-wire micro-fabricated anemometer with 3D directionality based on calorimetric principle is proposed, which is capable of measuring low speed airflow. This structure is realized by vertically bonding two different dies, which can be fabricated on the same wafer resulting in a simple fabrication process. Experiments on speed lower than 200 mm s-1 are conducted, showing good repeatability and directionality. The speed of airflow is controlled by the volumetric flow rate. The measured velocity sensitivity is 9.4 mV · s m-1, with relative direction sensitivity of 37.1 dB. The deviation between the expected and the measured directivity is analyzed by both theories and simulations. A correction procedure is proposed and turns out to be useful to eliminate this deviation. To further explore the potential of our device, we expose it to acoustic plane waves in a standing wave tube, showing consistent planar directivity of figure of eight. The measured velocity sensitivity at 1 kHz and 120 dBC is 4.4 mV · s m-1, with relative direction sensitivity of 27.0 dB. By using the correction method proposed above, the maximum angle error is about  ±2°, showing its good directionality accuracy.

  4. Test-retest reliability and four-week changes in cardiopulmonary fitness in stroke patients: evaluation using a robotics-assisted tilt table.

    PubMed

    Saengsuwan, Jittima; Berger, Lucia; Schuster-Amft, Corina; Nef, Tobias; Hunt, Kenneth J

    2016-09-06

    Exercise testing devices for evaluating cardiopulmonary fitness in patients with severe disability after stroke are lacking, but we have adapted a robotics-assisted tilt table (RATT) for cardiopulmonary exercise testing (CPET). Using the RATT in a sample of patients after stroke, this study aimed to investigate test-retest reliability and repeatability of CPET and to prospectively investigate changes in cardiopulmonary outcomes over a period of four weeks. Stroke patients with all degrees of disability underwent 3 separate CPET sessions: 2 tests at baseline (TB1 and TB2) and 1 test at follow up (TF). TB1 and TB2 were at least 24 h apart. TB2 and TF were 4 weeks apart. A RATT equipped with force sensors in the thigh cuffs, a work rate estimation algorithm and a real-time visual feedback system was used to guide the patients' exercise work rate during CPET. Test-retest reliability and repeatability of CPET variables were analysed using paired t-tests, the intraclass correlation coefficient (ICC), the coefficient of variation (CoV), and Bland and Altman limits of agreement. Changes in cardiopulmonary fitness during four weeks were analysed using paired t-tests. Seventeen sub-acute and chronic stroke patients (age 62.7 ± 10.4 years [mean ± SD]; 8 females) completed the test sessions. The median time post stroke was 350 days. There were 4 severely disabled, 1 moderately disabled and 12 mildly disabled patients. For test-retest, there were no statistically significant differences between TB1 and TB2 for most CPET variables. Peak oxygen uptake, peak heart rate, peak work rate and oxygen uptake at the ventilatory anaerobic threshold (VAT) and respiratory compensation point (RCP) showed good to excellent test-retest reliability (ICC 0.65-0.94). For all CPET variables, CoV was 4.1-14.5 %. The mean difference was close to zero in most of the CPET variables. There were no significant changes in most cardiopulmonary performance parameters during the 4-week period (TB2 vs TF). These findings provide the first evidence of test-retest reliability and repeatability of the principal CPET variables using the novel RATT system and testing methodology, and high success rates in identification of VAT and RCP: good to excellent test-retest reliability and repeatability were found for all submaximal and maximal CPET variables. Reliability and repeatability of the main CPET parameters in stroke patients on the RATT were comparable to previous findings in stroke patients using standard exercise testing devices. The RATT has potential to be used as an alternative exercise testing device in patients who have limitations for use of standard exercise testing devices.

  5. Retrieval and sleep both counteract the forgetting of spatial information.

    PubMed

    Antony, James W; Paller, Ken A

    2018-06-01

    Repeatedly studying information is a good way to strengthen memory storage. Nevertheless, testing recall often produces superior long-term retention. Demonstrations of this testing effect, typically with verbal stimuli, have shown that repeated retrieval through testing reduces forgetting. Sleep also benefits memory storage, perhaps through repeated retrieval as well. That is, memories may generally be subject to forgetting that can be counteracted when memories become reactivated, and there are several types of reactivation: (i) via intentional restudying, (ii) via testing, (iii) without provocation during wake, or (iv) during sleep. We thus measured forgetting for spatial material subjected to repeated study or repeated testing followed by retention intervals with sleep versus wake. Four groups of subjects learned a set of visual object-location associations and either restudied the associations or recalled locations given the objects as cues. We found the advantage for restudied over retested information was greater in the PM than AM group. Additional groups tested at 5-min and 1-wk retention intervals confirmed previous findings of greater relative benefits for restudying in the short-term and for retesting in the long-term. Results overall support the conclusion that repeated reactivation through testing or sleeping stabilizes information against forgetting. © 2018 Antony and Paller; Published by Cold Spring Harbor Laboratory Press.

  6. Amino acid sequence analysis of the annexin super-gene family of proteins.

    PubMed

    Barton, G J; Newman, R H; Freemont, P S; Crumpton, M J

    1991-06-15

    The annexins are a widespread family of calcium-dependent membrane-binding proteins. No common function has been identified for the family and, until recently, no crystallographic data existed for an annexin. In this paper we draw together 22 available annexin sequences consisting of 88 similar repeat units, and apply the techniques of multiple sequence alignment, pattern matching, secondary structure prediction and conservation analysis to the characterisation of the molecules. The analysis clearly shows that the repeats cluster into four distinct families and that greatest variation occurs within the repeat 3 units. Multiple alignment of the 88 repeats shows amino acids with conserved physicochemical properties at 22 positions, with only Gly at position 23 being absolutely conserved in all repeats. Secondary structure prediction techniques identify five conserved helices in each repeat unit and patterns of conserved hydrophobic amino acids are consistent with one face of a helix packing against the protein core in predicted helices a, c, d, e. Helix b is generally hydrophobic in all repeats, but contains a striking pattern of repeat-specific residue conservation at position 31, with Arg in repeats 4 and Glu in repeats 2, but unconserved amino acids in repeats 1 and 3. This suggests repeats 2 and 4 may interact via a buried saltbridge. The loop between predicted helices a and b of repeat 3 shows features distinct from the equivalent loop in repeats 1, 2 and 4, suggesting an important structural and/or functional role for this region. No compelling evidence emerges from this study for uteroglobin and the annexins sharing similar tertiary structures, or for uteroglobin representing a derivative of a primordial one-repeat structure that underwent duplication to give the present day annexins. The analyses performed in this paper are re-evaluated in the Appendix, in the light of the recently published X-ray structure for human annexin V. The structure confirms most of the predictions and shows the power of techniques for the determination of tertiary structural information from the amino acid sequences of an aligned protein family.

  7. Serial-order learning impairment and hypersensitivity-to-interference in dyscalculia.

    PubMed

    De Visscher, Alice; Szmalec, Arnaud; Van Der Linden, Lize; Noël, Marie-Pascale

    2015-11-01

    In the context of heterogeneity, the different profiles of dyscalculia are still hypothetical. This study aims to link features of mathematical difficulties to certain potential etiologies. First, we wanted to test the hypothesis of a serial-order learning deficit in adults with dyscalculia. For this purpose we used a Hebb repetition learning task. Second, we wanted to explore a recent hypothesis according to which hypersensitivity-to-interference hampers the storage of arithmetic facts and leads to a particular profile of dyscalculia. We therefore used interfering and non-interfering repeated sequences in the Hebb paradigm. A final test was used to assess the memory trace of the non-interfering sequence and the capacity to manipulate it. In line with our predictions, we observed that people with dyscalculia who show good conceptual knowledge in mathematics but impaired arithmetic fluency suffer from increased sensitivity-to-interference compared to controls. Secondly, people with dyscalculia who show a deficit in a global mathematical test suffer from a serial-order learning deficit characterized by a slow learning and a quick degradation of the memory trace of the repeated sequence. A serial-order learning impairment could be one of the explanations for a basic numerical deficit, since it is necessary for the number-word sequence acquisition. Among the different profiles of dyscalculia, this study provides new evidence and refinement for two particular profiles. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. High-resolution compact shear stress sensor for direct measurement of skin friction in fluid flow

    NASA Astrophysics Data System (ADS)

    Xu, Muchen; Kim, Chang-Jin ``Cj''

    2015-11-01

    The high-resolution measurement of skin friction in complex flows has long been of great interest but also a challenge in fluid mechanics. Compared with indirect measurement methods (e.g., laser Doppler velocimetry), direct measurement methods (e.g., floating element) do not involve any analogy and assumption but tend to suffer from instrumentation challenges, such as low sensing resolution or misalignments. Recently, silicon micromachined floating plates showed good resolution and perfect alignment but were too small for general purposes and too fragile to attach other surface samples repeatedly. In this work, we report a skin friction sensor consisting of a monolithic floating plate and a high-resolution optical encoder to measure its displacement. The key for the high resolution is in the suspension beams, which are very narrow (e.g., 0.25 mm) to sense small frictions along the flow direction but thick (e.g., 5 mm) to be robust along all other directions. This compact, low profile, and complete sensor is easy to use and allows repeated attachment and detachment of surface samples. The sheer-stress sensor has been tested in water tunnel and towing tank at different flow conditions, showing high sensing resolution for skin friction measurement. Supported by National Science Foundation (NSF) (No. 1336966) and Defense Advanced Research Projects Agency (DARPA) (No. HR0011-15-2-0021).

  9. Spatio-temporal Variations of Characteristic Repeating Earthquake Sequences along the Middle America Trench in Mexico

    NASA Astrophysics Data System (ADS)

    Dominguez, L. A.; Taira, T.; Hjorleifsdottir, V.; Santoyo, M. A.

    2015-12-01

    Repeating earthquake sequences are sets of events that are thought to rupture the same area on the plate interface and thus provide nearly identical waveforms. We systematically analyzed seismic records from 2001 through 2014 to identify repeating earthquakes with highly correlated waveforms occurring along the subduction zone of the Cocos plate. Using the correlation coefficient (cc) and spectral coherency (coh) of the vertical components as selection criteria, we found a set of 214 sequences whose waveforms exceed cc≥95% and coh≥95%. Spatial clustering along the trench shows large variations in repeating earthquakes activity. Particularly, the rupture zone of the M8.1, 1985 earthquake shows an almost absence of characteristic repeating earthquakes, whereas the Guerrero Gap zone and the segment of the trench close to the Guerrero-Oaxaca border shows a significantly larger number of repeating earthquakes sequences. Furthermore, temporal variations associated to stress changes due to major shows episodes of unlocking and healing of the interface. Understanding the different components that control the location and recurrence time of characteristic repeating sequences is a key factor to pinpoint areas where large megathrust earthquakes may nucleate and consequently to improve the seismic hazard assessment.

  10. Vienna SAC-SOS: Analysis of the European VLBI Sessions

    NASA Astrophysics Data System (ADS)

    Ros, C. T.; Pavetich, P.; Nilsson, T.; Böhm, J.; Schuh, H.

    2012-12-01

    The Institute of Geodesy and Geophysics (IGG) of the Vienna University of Technology as an IVS Special Analysis Center for Specific Observing Sessions (SAC-SOS) has analyzed the European VLBI sessions using the software VieVS. Between 1990 and 2011, 115 sessions have been carried out. The analyzed baselines have lengths ranging from approximately 445 to 4580 km, and they show good repeatabilities, apart from the ones containing station Simeiz. The station velocities have also been investigated. The stations situated in the stable part of Europe have not shown significant relative movements w.r.t. Wettzell, whereas the stations located in the northern areas have the largest vertical motions as a result of the post glacial isostatic rebound of the zone. The stations placed in Italy, around the Black Sea, in Siberia, and near the Arctic Circle show the largest relative horizontal motions because they belong to different geodynamical units.

  11. Determination of Tryptamines and β-Carbolines in Ayahuasca Beverage Consumed During Brazilian Religious Ceremonies.

    PubMed

    Santos, Mônica Cardoso; Navickiene, Sandro; Gaujac, Alain

    2017-05-01

    Ayahuasca is a potent hallucinogenic beverage prepared from Banisteriopsis caapi in combination with other psychoactive plants. N,N-dimethyltryptamine, tryptamine, harmine, harmaline, harmalol, and tetrahydroharmine were quantified in ayahuasca samples using a simple and low-cost method based on SPE and LC with UV diode-array detection. The experimental variables that affect the SPE method, such as type of solid phase and nature of solvent, were optimized. The method showed good linearity (r > 0.9902) and repeatability (RSD < 0.8%) for alkaloid compounds, with an LOD of 0.12 mg/L. The proposed method was used to analyze 20 samples from an ayahuasca cooking process from a religious group located in the municipality of Fortaleza, state of Ceará, Brazil. The results showed that concentrations of the target compounds ranged from 0.3 to 36.7 g/L for these samples.

  12. A new ring-shaped graphite monitor ionization chamber

    NASA Astrophysics Data System (ADS)

    Yoshizumi, M. T.; Caldas, L. V. E.

    2010-07-01

    A ring-shaped monitor ionization chamber was developed at the Instituto de Pesquisas Energéticas e Nucleares. This ionization chamber presents an entrance window of aluminized polyester foil. The guard ring and collecting electrode are made of graphite coated Lucite plates. The main difference between this new ionization chamber and commercial monitor chambers is its ring-shaped design. The new monitor chamber has a central hole, allowing the passage of the direct radiation beam without attenuation; only the penumbra radiation is measured by the sensitive volume. This kind of ionization chamber design has already been tested, but using aluminium electrodes. By changing the electrode material from aluminium to a graphite coating, an improvement in the chamber response stability was expected. The pre-operational tests, as saturation curve, recombination loss and polarity effect showed satisfactory results. The repeatability and the long-term stability tests were also evaluated, showing good agreement with international recommendations.

  13. 40 CFR 1065.310 - Torque calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... maintenance. Use good engineering judgment to repeat the calibration. Follow the torque transducer... the U.S. National Oceanographic and Atmospheric Administration's surface gravity prediction Web site at http://www.ngs.noaa.gov/cgi-bin/grav_pdx.prl. If this Web site is unavailable, you may use the...

  14. 40 CFR 1065.310 - Torque calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... maintenance. Use good engineering judgment to repeat the calibration. Follow the torque transducer... the U.S. National Oceanographic and Atmospheric Administration's surface gravity prediction Web site at http://www.ngs.noaa.gov/cgi-bin/grav_pdx.prl. If this Web site is unavailable, you may use the...

  15. A surrealistic mega-analysis of redisorganization theories

    PubMed Central

    Oxman, Andrew D; Sackett, David L; Chalmers, Iain; Prescott, Trine E

    2005-01-01

    Background We are sick and tired of being redisorganized. Objective To systematically review the empirical evidence for organizational theories and repeated reorganizations. Methods We did not find anything worth reading, other than Dilbert, so we fantasized. Unfortunately, our fantasies may well resemble many people's realities. We are sorry about this, but it is not our fault. Results We discovered many reasons for repeated reorganizations, the most common being ‘no good reason’. We estimated that trillions of dollars are being spent on strategic and organizational planning activities each year, thus providing lots of good reasons for hundreds of thousands of people, including us, to get into the business. New leaders who are intoxicated with the prospect of change further fuel perpetual cycles of redisorganization. We identified eight indicators of successful redisorganizations, including large consultancy fees paid to friends and relatives. Conclusions We propose the establishment of ethics committees to review all future redisorganization proposals in order to put a stop to uncontrolled, unplanned experimentation inflicted on providers and users of the health services. PMID:16319441

  16. Analysis and discussion on the experimental data of electrolyte analyzer

    NASA Astrophysics Data System (ADS)

    Dong, XinYu; Jiang, JunJie; Liu, MengJun; Li, Weiwei

    2018-06-01

    In the subsequent verification of electrolyte analyzer, we found that the instrument can achieve good repeatability and stability in repeated measurements with a short period of time, in line with the requirements of verification regulation of linear error and cross contamination rate, but the phenomenon of large indication error is very common, the measurement results of different manufacturers have great difference, in order to find and solve this problem, help enterprises to improve quality of product, to obtain accurate and reliable measurement data, we conducted the experimental evaluation of electrolyte analyzer, and the data were analyzed by statistical analysis.

  17. Expecting a good quality of life in health: assessing people with diverse diseases and conditions using the WHOQOL‐BREF

    PubMed Central

    Skevington, Suzanne M.; McCrate, Farah M.

    2011-01-01

    Abstract Background and objectives  Fulfilling patient expectations is central to defining a good quality of life (QoL) in health. The WHOQOL‐BREF was developed using novel, person‐centred methods and is a generic patient‐reported outcomes measure (PROM). However, without robust psychometric performance, PROMs cannot be relied upon to assess individuals. This study investigated the WHOQOL‐BREF (UK), with this use in mind. Design  Cross sectional with nested repeated measures. Setting and participants  Twenty‐seven disease groups or health conditions and healthy people were recruited at 38 UK sites, in a wide range of settings (n = 4628). Interventions  ‘Treatment as usual’; new and alternative interventions. Outcome measures  WHOQOL‐BREF (UK); SF‐36. Results  Respondent burden was low, as acceptability and feasibility were high. Internal consistency was excellent (0.92) and test–retest reliability good. Distinctive QoL profiles were found for diverse conditions. Musculoskeletal, psychiatric and cardiovascular patients reported the poorest QoL and also improved most during treatment. Overall, QoL was good, and best for healthy groups, supporting discriminant validity. Compared with the SF‐36, WHOQOL physical and psychological domains showed good concurrent validity, although social was weak. Small or moderate effect sizes confirmed responsiveness to change in specified domains for certain conditions and interventions. Age had a small impact on reporting QoL. Discussion and conclusion  The WHOQOL‐BREF is found to be a high quality patient‐centred generic tool suited to individual assessment in clinics, for research, and audit. PMID:21281412

  18. Evaluation of reliability and validity of three dental color-matching devices.

    PubMed

    Tsiliagkou, Aikaterini; Diamantopoulou, Sofia; Papazoglou, Efstratios; Kakaboura, Afrodite

    2016-01-01

    To assess the repeatability and accuracy of three dental color-matching devices under standardized and freehand measurement conditions. Two shade guides (Vita Classical A1-D4, Vita; and Vita Toothguide 3D-Master, Vita), and three color-matching devices (Easyshade, Vita; SpectroShade, MHT Optic Research; and ShadeVision, X-Rite) were used. Five shade tabs were selected from the Vita Classical A1-D4 (A2, A3.5, B1, C4, D3), and five from the Vita Toothguide 3D-Master (1M1, 2R1.5, 3M2, 4L2.5, 5M3) shade guides. Each shade tab was recorded 15 continuous, repeated times with each device under two different measurement conditions (standardized, and freehand). Both qualitative (color shade) and quantitative (L, a, and b) color characteristics were recorded. The color difference (ΔE) of each recorded value with the known values of the shade tab was calculated. The repeatability of each device was evaluated by the coefficient of variance. The accuracy of each device was determined by comparing the recorded values with the known values of the reference shade tab (one sample t test; α = 0.05). The agreement between the recorded shade and the reference shade tab was calculated. The influence of the parameters (devices and conditions) on the parameter ΔE was investigated (two-way ANOVA). Comparison of the devices was performed with Bonferroni pairwise post-hoc analysis. Under standardized conditions, repeatability of all three devices was very good, except for ShadeVision with Vita Classical A1-D4. Accuracy ranged from good to fair, depending on the device and the shade guide. Under freehand conditions, repeatability and accuracy for Easyshade and ShadeVision were negatively influenced, but not for SpectroShade, regardless of the shade guide. Based on the total of the color parameters assessed per device, SpectroShade was the most reliable of the three color-matching devices studied.

  19. Repeatability and correlations of dynamic contrast enhanced and T2* MRI in patients with advanced pancreatic ductal adenocarcinoma.

    PubMed

    Klaassen, Remy; Gurney-Champion, Oliver J; Wilmink, Johanna W; Besselink, Marc G; Engelbrecht, Marc R W; Stoker, Jaap; Nederveen, Aart J; van Laarhoven, Hanneke W M

    2018-07-01

    In current oncological practice of pancreatic ductal adenocarcinoma (PDAC), there is a great demand for response predictors and markers for early treatment evaluation. In this study, we investigated the repeatability and the interaction of dynamic contrast enhanced (DCE) and T2* MRI in patients with advanced PDAC to enable for such evaluation using these techniques. 15 PDAC patients underwent two DCE, T2* and anatomical 3 T MRI sessions before start of treatment. Parametric maps were calculated for the transfer constant (K trans ), rate constant (k ep ), extracellular extravascular space (v e ) and perfusion fraction (v p ). Quantitative R2* (1/T2*) maps were obtained from the multi-echo T2* images. Differences between normal and cancerous pancreas were determined using a Wilcoxon matched pairs test. Repeatability was obtained using Bland-Altman analysis and relations between DCE and T2*/R2* were observed by Spearman correlation and voxel-wise binned plots of tumor voxels. PDAC K trans (p = 0.007), k ep (p < 0.001), v p (p = 0.035) were lower and v e (p < 0.001) was higher compared to normal pancreas. The coefficient of variation between sessions was 21.8% for K trans , 9.9% for k ep , 19.3% for v e , 18.2% for v p and 18.7% for R2*. Variation between patients ranged from 20.2% for k ep to 43.6% for K trans . In the tumor both K trans (r = 0.56, p = 0.030) and v e (r = 0.54, p = 0.037) showed a positive correlation with T2*. Voxel wise analysis showed a steep increase in R2* for tumor voxels with lower K trans and v e . We showed good repeatability of DCE and T2* related MRI parameters in advanced PDAC patients. Furthermore, we have illustrated the relation of DCE K trans and v e with tissue T2* and R2* indicating substantial value of these parameters for detecting tumor hypoxia in future studies. The results from our study pave the way for further response evaluation studies and patient selection based on DCE and T2* parameters. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. A gas chromatography-mass spectrometry assay to quantify camphor extracted from goat serum.

    PubMed

    Lee, Kyung-Min; Dai, Susie Y; Herrman, Timothy J; Musser, Jeffrey M B

    2012-09-15

    A sensitive gas chromatography-mass spectrometry (GC-MS) method was developed and validated for quantification and pharmacokinetics of camphor, a major monoterpene of juniper plant, in goat serum. Camphor and internal standard (terpinolene) eluates from solid phase extraction (SPE) with ethyl acetate yielded well resolved peaks and were clearly identified in total and selected ion chromatograms. The elution and injection volumes were optimized for improved detection and quantification of camphor based on peak shape, signal to noise ratio, recoveries, and repeatability. The matrix calibration curve with the good linearity (R(2)=0.998) and response in the range of 0.005-10.0 μg/mL was used to determine camphor concentration in goat serum. The GC-MS method offered sufficiently low limits of detection (1 ng/mL) and quantitation (3 ng/mL) for camphor concentration in goat serum for the pharmacokinetic study. The proposed method showed good intra- and inter-day variation with relative standard deviation (RSD) of 0.2-7.7% and produced good recovery (96.0-111.6%) and reproducibility (1.6-6.1%) at all spiked levels. Using this method on serum samples obtained from two goats orally dosed with camphor confirmed that the method is suitable for camphor studies in animals. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Construction and validation of a Tamil logMAR chart.

    PubMed

    Varadharajan, Srinivasa; Srinivasan, Krithica; Kumaresan, Brindha

    2009-09-01

    To design, construct and validate a new Tamil logMAR visual acuity chart based on current recommendations. Ten Tamil letters of equal legibility were identified experimentally and were used in the chart. Two charts, one internally illuminated and one externally illuminated, were constructed for testing at 4 m distance. The repeatability of the two charts was tested. For validation, the two charts were compared with a standard English logMAR chart (ETDRS). When compared to the ETDRS chart, a difference of 0.06 +/- 0.07 and 0.07 +/- 0.07 logMAR was found for the internally and externally illuminated charts respectively. Limits of agreement between the internally illuminated Tamil logMAR chart and ETDRS chart were found to be (-0.08, 0.19), and (-0.07, 0.20) for the externally illuminated chart. The test - retest results showed a difference of 0.02 +/- 0.04 and 0.02 +/- 0.06 logMAR for the internally and externally illuminated charts respectively. Limits of agreement for repeated measurements for the internally illuminated Tamil logMAR chart were found to be (-0.06, 0.10), and (-0.10, 0.14) for the externally illuminated chart. The newly constructed Tamil logMAR charts have good repeatability. The difference in visual acuity scores between the newly constructed Tamil logMAR chart and the standard English logMAR chart was within acceptable limits. This new chart can be used for measuring visual acuity in the literate Tamil population.

  2. Upper and Lower Neck Loads in Belted Human Surrogates in Frontal Impacts

    PubMed Central

    Yoganandan, Narayan; Pintar, Frank A.; Moore, Jason; Rinaldi, James; Schlick, Michael; Maiman, Dennis J.

    2012-01-01

    The upper and lower neck loads in the restrained Hybrid III dummy and Test Device for Human Occupant Restraint (THOR) were computed in simulated frontal impact sled tests at low, medium, and high velocities; repeatability performance of the two dummies were evaluated at all energy inputs; peak forces and moments were compared with computed loads at the occipital condyles and cervical-thoracic junctions from tests using post mortem human surrogates (PMHS). A custom sled buck was used to position the surrogates. Repeated tests were conducted at each velocity for each dummy and sufficient time was allowed to elapse between the two experiments. The upper and lower neck forces and moments were determined from load cell measures and its locations with respect to the ends of the neck. Both dummies showed good repeatability for axial and shear forces and bending moments at all changes in velocity inputs. Morphological characteristics in the neck loading responses were similar in all surrogates, although the peak magnitudes of the variables differed. In general, the THOR better mimicked the PMHS response than the Hybrid III dummy, and factors such as neck design and chest compliance were attributed to the observed variations. While both dummies were not designed for use at the two extremes of the tested velocities, results from the present study indicate that, currently the THOR may be the preferred anthropomorphic testing device in crashworthiness research studies and full-scale vehicle tests at all velocities. PMID:23169123

  3. New Multilocus Variable-Number Tandem-Repeat Analysis Tool for Surveillance and Local Epidemiology of Bacterial Leaf Blight and Bacterial Leaf Streak of Rice Caused by Xanthomonas oryzae

    PubMed Central

    Poulin, L.; Grygiel, P.; Magne, M.; Rodriguez-R, L. M.; Forero Serna, N.; Zhao, S.; El Rafii, M.; Dao, S.; Tekete, C.; Wonni, I.; Koita, O.; Pruvost, O.; Verdier, V.; Vernière, C.

    2014-01-01

    Multilocus variable-number tandem-repeat analysis (MLVA) is efficient for routine typing and for investigating the genetic structures of natural microbial populations. Two distinct pathovars of Xanthomonas oryzae can cause significant crop losses in tropical and temperate rice-growing countries. Bacterial leaf streak is caused by X. oryzae pv. oryzicola, and bacterial leaf blight is caused by X. oryzae pv. oryzae. For the latter, two genetic lineages have been described in the literature. We developed a universal MLVA typing tool both for the identification of the three X. oryzae genetic lineages and for epidemiological analyses. Sixteen candidate variable-number tandem-repeat (VNTR) loci were selected according to their presence and polymorphism in 10 draft or complete genome sequences of the three X. oryzae lineages and by VNTR sequencing of a subset of loci of interest in 20 strains per lineage. The MLVA-16 scheme was then applied to 338 strains of X. oryzae representing different pathovars and geographical locations. Linkage disequilibrium between MLVA loci was calculated by index association on different scales, and the 16 loci showed linear Mantel correlation with MLSA data on 56 X. oryzae strains, suggesting that they provide a good phylogenetic signal. Furthermore, analyses of sets of strains for different lineages indicated the possibility of using the scheme for deeper epidemiological investigation on small spatial scales. PMID:25398857

  4. Slot angle detecting method for fiber fixed chip

    NASA Astrophysics Data System (ADS)

    Zhang, Jiaquan; Wang, Jiliang; Zhou, Chaochao

    2018-04-01

    The slot angle of fiber fixed chip has a significant impact on performance of photoelectric devices. In order to solve the actual engineering problem, this paper put forward a detecting method based on imaging processing. Because the images have very low contrast that is hardly segmented, so this paper proposes imaging segment methods based on edge character. Then get fixed chip edge line slope k2 and calculate the fiber fixed slot line slope k1, which can be used calculating the slot angle. Lastly, test the repeatability and accuracy of system, which show that this method has very fast operation speed and good robustness. Clearly, it is also satisfied to the actual demand of fiber fixed chip slot angle detection.

  5. A Facile Large-Scale Synthesis of Porous SnO2 by Bronze for Superior Lithium Storage and Gas Sensing Properties Through a Wet Chemical Reaction Strategy

    NASA Astrophysics Data System (ADS)

    Yue, Lu; Ge, Jingjing; Luo, Gaixia; Bian, Kaiting; Yin, Chao; Guan, Rongfeng; Zhang, Wenhui; Zhou, Zheng; Wang, Kaixin; Guo, Xiufeng

    2018-03-01

    A facile approach to prepare porous SnO2 and SnO2/C composite with Cu-Sn alloy as raw material by wet chemical reaction strategy has been developed. The prepared porous SnO2 and its carbon composite showed homogeneous mesoporous structure and high surface area, displayed superior rate performance and high reversible capacity of 625 mAh g-1 and 1185 mAh g-1 over 800 cycles at 0.4 A g-1, respectively. Compared with commercial SnO2, porous SnO2 sensor presented higher response, faster response/recovery capability, good selectivity and repeatability to ethanol at 180°C.

  6. Performance data of the new free-piston shock tunnel at GALCIT

    NASA Technical Reports Server (NTRS)

    Hornung, Hans G.

    1992-01-01

    The new free-piston shock tunnel has been partially calibrated, and a range of operating conditions has been found. A large number of difficulties were encountered during the shake-down period, of which the ablation of various parts was the most severe. Solutions to these problems were found. The general principles of high-enthalpy simulation are outlined, and the parameter space covered by T5 is given. Examples of the operating data show that, with care, excellent repeatability may be obtained. The temporal uniformity of the reservoir pressure is very good, even at high enthalpy, because it is possible to operate at tailored-interface and tuned-piston conditions over the whole enthalpy range. Examples of heat transfer and Pitot-pressure measurements are also presented.

  7. Wing Torsional Stiffness Tests of the Active Aeroelastic Wing F/A-18 Airplane

    NASA Technical Reports Server (NTRS)

    Lokos, William A.; Olney, Candida D.; Crawford, Natalie D.; Stauf, Rick; Reichenbach, Eric Y.

    2002-01-01

    The left wing of the Active Aeroelastic Wing (AAW) F/A-18 airplane has been ground-load-tested to quantify its torsional stiffness. The test has been performed at the NASA Dryden Flight Research Center in November 1996, and again in April 2001 after a wing skin modification was performed. The primary objectives of these tests were to characterize the wing behavior before the first flight, and provide a before-and-after measurement of the torsional stiffness. Two streamwise load couples have been applied. The wing skin modification is shown to have more torsional flexibility than the original configuration has. Additionally, structural hysteresis is shown to be reduced by the skin modification. Data comparisons show good repeatability between the tests.

  8. Achilles tendon reflex measuring system

    NASA Astrophysics Data System (ADS)

    Szebeszczyk, Janina; Straszecka, Joanna

    1995-06-01

    The examination of Achilles tendon reflex is widely used as a simple, noninvasive clinical test in diagnosis and pharmacological therapy monitoring in such diseases as: hypothyroidism, hyperthyroidism, diabetic neuropathy, the lower limbs obstructive angiopathies and intermittent claudication. Presented Achilles tendon reflect measuring system is based on the piezoresistive sensor connected with the cylinder-piston system. To determinate the moment of Achilles tendon stimulation a detecting circuit was used. The outputs of the measuring system are connected to the PC-based data acquisition board. Experimental results showed that the measurement accuracy and repeatability is good enough for diagnostics and therapy monitoring purposes. A user friendly, easy-to-operate measurement system fulfills all the requirements related to recording, presentation and storing of the patients' reflexograms.

  9. A fast, reliable, ultra high performance liquid chromatography method for the simultaneous determination of amino acids, biogenic amines and ammonium ions in cheese, using diethyl ethoxymethylenemalonate as a derivatising agent.

    PubMed

    Redruello, Begoña; Ladero, Victor; Cuesta, Isabel; Álvarez-Buylla, Jorge R; Martín, María Cruz; Fernández, María; Alvarez, Miguel A

    2013-08-15

    Derivatisation treatment with diethyl ethoxymethylenemalonate followed by ultra-HPLC allowed the simultaneous quantification of 22 amino acids, 7 biogenic amines and ammonium ions in cheese samples in under 10 min. This is the fastest elution time ever reported for such a resolution. The proposed method shows good linearity (R(2)>0.995) and sensitivity (detection limit 0.08-3.91 μM; quantification limit <13.02 μM). Intra- and inter-day repeatability ranged from 0.35% to 1.25% and from 0.85% to 5.2%, respectively. No significant effect of the cheese matrix was observed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Development and Validation of a HPTLC Method for Simultaneous Estimation of L-Glutamic Acid and γ-Aminobutyric Acid in Mice Brain

    PubMed Central

    Sancheti, J. S.; Shaikh, M. F.; Khatwani, P. F.; Kulkarni, Savita R.; Sathaye, Sadhana

    2013-01-01

    A new robust, simple and economic high performance thin layer chromatographic method was developed for simultaneous estimation of L-glutamic acid and γ-amino butyric acid in brain homogenate. The high performance thin layer chromatographic separation of these amino acid was achieved using n-butanol:glacial acetic acid:water (22:3:5 v/v/v) as mobile phase and ninhydrin as a derivatising agent. Quantitation of the method was achieved by densitometric method at 550 nm over the concentration range of 10-100 ng/spot. This method showed good separation of amino acids in the brain homogenate with Rf value of L-glutamic acid and γ-amino butyric acid as 21.67±0.58 and 33.67±0.58, respectively. The limit of detection and limit of quantification for L-glutamic acid was found to be 10 and 20 ng and for γ-amino butyric acid it was 4 and 10 ng, respectively. The method was also validated in terms of accuracy, precision and repeatability. The developed method was found to be precise and accurate with good reproducibility and shows promising applicability for studying pathological status of disease and therapeutic significance of drug treatment. PMID:24591747

  11. Development and Validation of a HPTLC Method for Simultaneous Estimation of L-Glutamic Acid and γ-Aminobutyric Acid in Mice Brain.

    PubMed

    Sancheti, J S; Shaikh, M F; Khatwani, P F; Kulkarni, Savita R; Sathaye, Sadhana

    2013-11-01

    A new robust, simple and economic high performance thin layer chromatographic method was developed for simultaneous estimation of L-glutamic acid and γ-amino butyric acid in brain homogenate. The high performance thin layer chromatographic separation of these amino acid was achieved using n-butanol:glacial acetic acid:water (22:3:5 v/v/v) as mobile phase and ninhydrin as a derivatising agent. Quantitation of the method was achieved by densitometric method at 550 nm over the concentration range of 10-100 ng/spot. This method showed good separation of amino acids in the brain homogenate with Rf value of L-glutamic acid and γ-amino butyric acid as 21.67±0.58 and 33.67±0.58, respectively. The limit of detection and limit of quantification for L-glutamic acid was found to be 10 and 20 ng and for γ-amino butyric acid it was 4 and 10 ng, respectively. The method was also validated in terms of accuracy, precision and repeatability. The developed method was found to be precise and accurate with good reproducibility and shows promising applicability for studying pathological status of disease and therapeutic significance of drug treatment.

  12. Graphene oxide decorated with silver nanoparticles as a coating on a stainless-steel fiber for solid-phase microextraction.

    PubMed

    Wang, Licheng; Hou, Xiudan; Li, Jubai; Liu, Shujuan; Guo, Yong

    2015-07-01

    A novel graphene oxide decorated with silver nanoparticles coating on a stainless-steel fiber for solid-phase microextraction was prepared. Scanning electron microscopy and X-ray photoelectron spectroscopy were used to characterize the coating surface and showed that silver nanoparticles were dispersed on the wrinkled graphene oxide surface. Coupled to gas chromatography with flame ionization detection, the extraction abilities of the fiber for polycyclic aromatic hydrocarbons were examined in the headspace solid-phase microextraction mode. The extraction parameters including adsorption time, adsorption temperature, salt concentration, desorption time and desorption temperature were investigated. Under the optimized condition, wide linearity with low limits of detection from 2 to 10 ng/L was obtained. The relative standard deviations for single-fiber repeatability and fiber-to-fiber reproducibility were less than 10.6 and 17.5%, respectively. The enrichment factors were from 1712.5 to 4503.7, showing the fiber has good extraction abilities. Moreover, the fiber exhibited a good stability and could be reused for more than 120 times. The established method was also applied for determination of polycyclic aromatic hydrocarbons in two real water samples and the recoveries of analytes ranged from 84.4-116.3% with relative standard deviations less than 16.2%. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Elevation Change of Drangajokull, Iceland, from Cloud-Cleared ICESat Repeat Profiles and GPS Ground-Survey Data

    NASA Technical Reports Server (NTRS)

    Shuman, Christopher A.; Sigurdsson, Oddur; Williams, Richard, Jr.; Hall, Dorothy K.

    2009-01-01

    Located on the Vestfirdir Northwest Fjords), DrangaJokull is the northernmost ice map in Iceland. Currently, the ice cap exceeds 900 m in elevation and covered an area of approx.l46 sq km in August 2004. It was about 204 sq km in area during 1913-1914 and so has lost mass during the 20th century. Drangajokull's size and accessibility for GPS surveys as well as the availability of repeat satellite altimetry profiles since late 2003 make it a good subject for change-detection analysis. The ice cap was surveyed by four GPS-equipped snowmobiles on 19-20 April 2005 and has been profiled in two places by Ice, Cloud. and land Elevation Satellite (ICESat) 'repeat tracks,' fifteen times from late to early 2009. In addition, traditional mass-balance measurements have been taken seasonally at a number of locations across the ice cap and they show positive net mass balances in 2004/2005 through 2006/2007. Mean elevation differences between the temporally-closest ICESat profiles and the GPS-derived digital-elevation model (DEM)(ICESat - DEM) are about 1.1 m but have standard deviations of 3 to 4 m. Differencing all ICESat repeats from the DEM shows that the overall elevation difference trend since 2003 is negative with losses of as much as 1.5 m/a from same season to same season (and similar elevation) data subsets. However, the mass balance assessments by traditional stake re-measurement methods suggest that the elevation changes where ICESat tracks 0046 and 0307 cross Drangajokull are not representative of the whole ice cap. Specifically, the area has experienced positive mass balance years during the time frame when ICESat data indicates substantial losses. This analysis suggests that ICESat-derived elevations may be used for multi-year change detection relative to other data but suggests that large uncertainties remain. These uncertainties may be due to geolocation uncertainty on steep slopes and continuing cloud cover that limits temporal and spatial coverage across the area.

  14. Predictive value of serum progesterone level on β-hCG check day in women with previous repeated miscarriages after in vitro fertilization.

    PubMed

    Kim, Yong Jin; Shin, Jung Ho; Hur, Jun Yong; Kim, Hoon; Ku, Seung-Yup; Suh, Chang Suk

    2017-01-01

    To evaluate the predictive value of the progesterone level at the beta-human chorionic gonadotropin (β-hCG) check day for ongoing pregnancy maintenance in in vitro fertilization (IVF) cycles in women with previous unexplained repeated miscarriages. One hundred and forty-eight women, with visible gestational sac after IVF, were recruited in this observational study. All subjects had unexplained recurrent miscarriages in more than two previous IVF cycles. The progesterone level at the β-hCG check day (i.e. 14 days after oocyte retrieval) was assessed. The area under the curve (AUC) of the progesterone level was evaluated to predict the ongoing pregnancy or miscarriage outcomes. The overall ongoing pregnancy rate was 60.8% (90/148). The cut-off value with β-hCG levels higher than 126.5 mIU/mL and with progesterone levels higher than 25.2 ng/mL could be the predictive factors for ongoing pregnancy maintenance (AUC = 0.788 and 0.826; sensitivity = 0.788 and 0.723; specificity = 0.689 and 0.833; P < 0.0001 and P < 0.0001, respectively). The miscarriage rates were 19.5% (15/77) in the women with β-hCG > 126.5 mIU/mL and 13.0% (10/77) in those with > 25.2 ng/mL. In the comparison of the ROC curves between both values, a similar significance was found. The subjects with β-hCG > 126.5 mIU/mL and progesterone > 25.2 ng/mL showed higher ongoing pregnancy rates [98.0% (49/50) vs. 41.8% (41/98)] than those with β-hCG ≤ 126.5 mIU/mL or progesterone ≤ 25.2 ng/mL. The progesterone level at 14 days after oocyte retrieval can be a good predictive marker for ongoing pregnancy maintenance in women with repeated IVF failure with miscarriage, together with the β-hCG level. The combined cut-off value of progesterone > 25.2 ng/mL and β-hCG > 126.5 mIU/mL may suggest a good prognosis.

  15. If Empowerment Is So Good, Why Does It Hurt?

    ERIC Educational Resources Information Center

    Holpp, Lawrence

    1995-01-01

    The following suggestions can make employee empowerment work: (1) do the basics first; (2) learn to do things flawlessly; (3) add new tasks only as old ones are mastered; (4) make new tasks work as flawlessly as the basics; and (5) repeat, ad infinitum. (Author/JOW)

  16. Repeated learning makes cultural evolution unique

    PubMed Central

    Strimling, Pontus; Enquist, Magnus; Eriksson, Kimmo

    2009-01-01

    Although genetic information is acquired only once, cultural information can be both abandoned and reacquired during an individual's lifetime. Therefore, cultural evolution will be determined not only by cultural traits' ability to spread but also by how good they are at sticking with an individual; however, the evolutionary consequences of this aspect of culture have not previously been explored. Here we show that repeated learning and multiple characteristics of cultural traits make cultural evolution unique, allowing dynamical phenomena we can recognize as specifically cultural, such as traits that both spread quickly and disappear quickly. Importantly, the analysis of our model also yields a theoretical objection to the popular suggestion that biological and cultural evolution can be understood in similar terms. We find that the possibility to predict long-term cultural evolution by some success index, analogous to biological fitness, depends on whether individuals have few or many opportunities to learn. If learning opportunities are few, we find that the existence of a success index may be logically impossible, rendering notions of “cultural fitness” meaningless. On the other hand, if individuals can learn many times, we find a success index that works, regardless of whether the transmission pattern is vertical, oblique, or horizontal. PMID:19666615

  17. Genome-wide Annotation and Comparative Analysis of Long Terminal Repeat Retrotransposons between Pear Species of P. bretschneideri and P. Communis

    PubMed Central

    Yin, Hao; Du, Jianchang; Wu, Jun; Wei, Shuwei; Xu, Yingxiu; Tao, Shutian; Wu, Juyou; Zhang, Shaoling

    2015-01-01

    Recent sequencing of the Oriental pear (P. bretschneideri Rehd.) genome and the availability of the draft genome sequence of Occidental pear (P. communis L.), has provided a good opportunity to characterize the abundance, distribution, timing, and evolution of long terminal repeat retrotransposons (LTR-RTs) in these two important fruit plants. Here, a total of 7247 LTR-RTs, which can be classified into 148 families, have been identified in the assembled Oriental pear genome. Unlike in other plant genomes, approximately 90% of these elements were found to be randomly distributed along the pear chromosomes. Further analysis revealed that the amplification timeframe of elements varies dramatically in different families, super-families and lineages, and the Copia-like elements have highest activity in the recent 0.5 million years (Mys). The data also showed that two genomes evolved with similar evolutionary rates after their split from the common ancestor ~0.77–1.66 million years ago (Mya). Overall, the data provided here will be a valuable resource for further investigating the impact of transposable elements on gene structure, expression, and epigenetic modification in the pear genomes. PMID:26631625

  18. Automated extraction and validation of children's gait parameters with the Kinect.

    PubMed

    Motiian, Saeid; Pergami, Paola; Guffey, Keegan; Mancinelli, Corrie A; Doretto, Gianfranco

    2015-12-02

    Gait analysis for therapy regimen prescription and monitoring requires patients to physically access clinics with specialized equipment. The timely availability of such infrastructure at the right frequency is especially important for small children. Besides being very costly, this is a challenge for many children living in rural areas. This is why this work develops a low-cost, portable, and automated approach for in-home gait analysis, based on the Microsoft Kinect. A robust and efficient method for extracting gait parameters is introduced, which copes with the high variability of noisy Kinect skeleton tracking data experienced across the population of young children. This is achieved by temporally segmenting the data with an approach based on coupling a probabilistic matching of stride template models, learned offline, with the estimation of their global and local temporal scaling. A preliminary study conducted on healthy children between 2 and 4 years of age is performed to analyze the accuracy, precision, repeatability, and concurrent validity of the proposed method against the GAITRite when measuring several spatial and temporal children's gait parameters. The method has excellent accuracy and good precision, with segmenting temporal sequences of body joint locations into stride and step cycles. Also, the spatial and temporal gait parameters, estimated automatically, exhibit good concurrent validity with those provided by the GAITRite, as well as very good repeatability. In particular, on a range of nine gait parameters, the relative and absolute agreements were found to be good and excellent, and the overall agreements were found to be good and moderate. This work enables and validates the automated use of the Kinect for children's gait analysis in healthy subjects. In particular, the approach makes a step forward towards developing a low-cost, portable, parent-operated in-home tool for clinicians assisting young children.

  19. Post-operative rotator cuff integrity, based on Sugaya's classification, can reflect abduction muscle strength of the shoulder.

    PubMed

    Yoshida, Masahito; Collin, Phillipe; Josseaume, Thierry; Lädermann, Alexandre; Goto, Hideyuki; Sugimoto, Katumasa; Otsuka, Takanobu

    2018-01-01

    Magnetic resonance (MR) imaging is common in structural and qualitative assessment of the rotator cuff post-operatively. Rotator cuff integrity has been thought to be associated with clinical outcome. The purpose of this study was to evaluate the inter-observer reliability of cuff integrity (Sugaya's classification) and assess the correlation between Sugaya's classification and the clinical outcome. It was hypothesized that Sugaya's classification would show good reliability and good correlation with the clinical outcome. Post-operative MR images were taken two years post-operatively, following arthroscopic rotator cuff repair. For assessment of inter-rater reliability, all radiographic evaluations for the supraspinatus muscle were done by two orthopaedic surgeons and one radiologist. Rotator cuff integrity was classified into five categories, according to Sugaya's classification. Fatty infiltration was graded into four categories, based on the Fuchs' classification grading system. Muscle hypotrophy was graded as four grades, according to the scale proposed by Warner. The clinical outcome was assessed according to the constant scoring system pre-operatively and 2 years post-operatively. Of the sixty-two consecutive patients with full-thickness rotator cuff tears, fifty-two patients were reviewed in this study. These subjects included twenty-three men and twenty-nine women, with an average age of fifty-seven years. In terms of the inter-rater reliability between orthopaedic surgeons, Sugaya's classification showed the highest agreement [ICC (2.1) = 0.82] for rotator cuff integrity. The grade of fatty infiltration and muscle atrophy demonstrated good agreement, respectively (0.722 and 0.758). With regard to the inter-rater reliability between orthopaedic surgeon and radiologist, Sugaya's classification showed good reliability [ICC (2.1) = 0.70]. On the other hand, fatty infiltration and muscle hypotrophy classifications demonstrated fair and moderate agreement [ICC (2.1) = 0.39 and 0.49]. Although no significant correlation was found between overall post-operative constant score and Sugaya's classification, Sugaya's classification indicated significant correlation with the muscle strength score. Sugaya's classification showed repeatability and good agreement between the orthopaedist and radiologist, who are involved in the patient care for the rotator cuff tear. Common classification of rotator cuff integrity with good reliability will give appropriate information for clinicians to improve the patient care of the rotator cuff tear. This classification also would be helpful to predict the strength of arm abduction in the scapular plane. IV.

  20. Analysis of aldehydes in beer by gas-diffusion microextraction: characterization by high-performance liquid chromatography-diode-array detection-atmospheric pressure chemical ionization-mass spectrometry.

    PubMed

    Gonçalves, Luís Moreira; Magalhães, Paulo Jorge; Valente, Inês Maria; Pacheco, João Grosso; Dostálek, Pavel; Sýkora, David; Rodrigues, José António; Barros, Aquiles Araújo

    2010-06-11

    In this work, a recently developed extraction technique for sample preparation aiming the analysis of volatile and semi-volatile compounds named gas-diffusion microextraction (GDME) is applied in the chromatographic analysis of aldehydes in beer. Aldehydes-namely acetaldehyde (AA), methylpropanal (MA) and furfural (FA)-were simultaneously extracted and derivatized with 2,4-dinitrophenylhydrazine (DNPH), then the derivatives were separated and analyzed by high-performance liquid chromatography with spectrophotometric detection (HPLC-UV). The identity of the eluted compounds was confirmed by high-performance liquid chromatography-atmospheric pressure chemical ionization-mass-spectrometry detection in the negative ion mode (HPLC-APCI-MS). The developed methodology showed good repeatability (ca. 5%) and linearity as well as good limits of detection (AA-12.3, FA-1.5 and MA 5.4microgL(-1)) and quantification (AA-41, FA-4.9 and MA 18microgL(-1)); it also appears to be competitive in terms of speed and cost of analysis. Copyright 2010 Elsevier B.V. All rights reserved.

  1. Structural Analysis and Testing of an Erectable Truss for Precision Segmented Reflector Application

    NASA Technical Reports Server (NTRS)

    Collins, Timothy J.; Fichter, W. B.; Adams, Richard R.; Javeed, Mehzad

    1995-01-01

    This paper describes analysis and test results obtained at Langley Research Center (LaRC) on a doubly curved testbed support truss for precision reflector applications. Descriptions of test procedures and experimental results that expand upon previous investigations are presented. A brief description of the truss is given, and finite-element-analysis models are described. Static-load and vibration test procedures are discussed, and experimental results are shown to be repeatable and in generally good agreement with linear finite-element predictions. Truss structural performance (as determined by static deflection and vibration testing) is shown to be predictable and very close to linear. Vibration test results presented herein confirm that an anomalous mode observed during initial testing was due to the flexibility of the truss support system. Photogrammetric surveys with two 131-in. reference scales show that the root-mean-square (rms) truss-surface accuracy is about 0.0025 in. Photogrammetric measurements also indicate that the truss coefficient of thermal expansion (CTE) is in good agreement with that predicted by analysis. A detailed description of the photogrammetric procedures is included as an appendix.

  2. π-Extended triptycene-based material for capillary gas chromatographic separations.

    PubMed

    Yang, Yinhui; Wang, Qinsi; Qi, Meiling; Huang, Xuebin

    2017-10-02

    Triptycene-based materials feature favorable physicochemical properties and unique molecular recognition ability that offer good potential as stationary phases for capillary gas chromatography (GC). Herein, we report the investigation of utilizing a π-extended triptycene material (denoted as TQPP) for GC separations. As a result, the TQPP capillary column exhibited high column efficiency of 4030 plates m -1 and high-resolution performance for a wide range of analytes, especially structural and positional isomers. Interestingly, the TQPP stationary phase showed unique shape selectivity for alkanes isomers and preferential retention for analytes with halogen atoms and H-bonding nature mainly through their halogen-bonding and H-bonding interactions. In addition, the TQPP column had good repeatability and reproducibility with the RSD values of 0.02-0.34% for run-to-run, 0.09-0.80% for day-to-day and 1.4-5.2% for column-to-column, respectively, and favorable thermal stability up to 280 °C. This work demonstrates the promising future of triptycene-based materials as a new class of stationary phases for GC separations. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. General radiographic attributes of optically stimulated luminescence dosimeters: A basic insight

    NASA Astrophysics Data System (ADS)

    Musa, Y.; Hashim, S.; Ghoshal, S. K.; Bradley, D. A.; Ahmad, N. E.; Karim, M. K. A.; Hashim, A.; Kadir, A. B. A.

    2018-06-01

    We report the ubiquitous radiographic characteristics of optically stimulated luminescence dosimeters (OSLD) so called nanoDot OSLDs (Landauer Inc., Glendwood, IL). The X-ray irradiations were performed in free air ambiance to inspect the repeatability, the reproducibility, the signal depletion, the element correction factors (ECFs), the dose response and the energy dependence. Repeatability of multiple readouts after single irradiation to 10 mGy revealed a coefficient of variation below 3%, while the reproducibility in repeated irradiation-readout-annealing cycles was above 2%. The OSL signal depletion for three nanoDots with simultaneous irradiation to 20 mGy and sequential readouts of 25 times displayed a consistent signal reduction ≈0.5% per readout with R2 values over 0.98. ECFs for individual OSLDs were varied from 0.97 to 1.03. In the entire dose range under 80 kV, a good linearity with an R2 exceeding 0.99 was achieved. Besides, the percentage difference between OSLD and ion-chamber dose was less than 5%, which was superior to TLD. The X-ray photon irradiated energy response factors (between 0.76 and 1.12) in the range of 40-150 kV (26.1-61.2 keV) exhibited significant energy dependence. Indeed, the nanoDot OSLDs disclosed good repeatability, reproducibility and linearity. The OSLDs measured doses were closer to ion-chamber doses than that of TLD. It can be further improved up to ≈3% by applying the individual dosimeter ECF. On top, the energy dependent uncertainties can be minimized using the energy correction factors. It is established that the studied nanoDot OSLDs are prospective for measuring entrance dose in general radiographic practices.

  4. Reference values for respiratory rate in the first 3 years of life.

    PubMed

    Rusconi, F; Castagneto, M; Gagliardi, L; Leo, G; Pellegatta, A; Porta, N; Razon, S; Braga, M

    1994-09-01

    Raised respiratory rate is a useful sign to diagnose lower respiratory infections in childhood. However, the normal range for respiratory rate has not been defined in a proper, large sample. To assess the respiratory rate in a large number of infants and young children in order to construct percentile curves by age; to determine the repeatability to the assessment using a stethoscope and compare it with observation. Respiratory rate was recorded for 1 minute with a stethoscope in 618 infants and children, aged 15 days to 3 years old, without respiratory infections or any other severe disease when awake and calm and when asleep. In 50 subjects we compared respiratory rate taken 30 to 60 minutes apart to assess repeatability, and in 50 others we compared simultaneous counts obtained by stethoscope versus observation. Repeatability was good as the standard deviation of differences was 2.5 breaths/minute in awake and 1.7 breaths/minute in asleep children. Respiratory rate obtained with a stethoscope was systematically higher than that obtained by observation (mean difference 2.6 breaths/minute in awake and 1.8 breaths/minute in asleep children; P = .015 and P < .001, respectively). A decrease in respiratory rate with age was seen for both states, and it was faster in the first few months of life when also a greater dispersion of values was observed. A second degree polynomial curve accurately fitted the data. Reference percentile values were developed from these data. The repeatability of respiratory rate measured with a stethoscope was good. Percentile curves would be particularly helpful in the first months of life when the decline in respiratory rate is very rapid and prevents to use cut off values for defining "normality."

  5. The characterization of a new set of EST-derived simple sequence repeat (SSR) markers as a resource for the genetic analysis of Phaseolus vulgaris

    PubMed Central

    2011-01-01

    Background Over recent years, a growing effort has been made to develop microsatellite markers for the genomic analysis of the common bean (Phaseolus vulgaris) to broaden the knowledge of the molecular genetic basis of this species. The availability of large sets of expressed sequence tags (ESTs) in public databases has given rise to an expedient approach for the identification of SSRs (Simple Sequence Repeats), specifically EST-derived SSRs. In the present work, a battery of new microsatellite markers was obtained from a search of the Phaseolus vulgaris EST database. The diversity, degree of transferability and polymorphism of these markers were tested. Results From 9,583 valid ESTs, 4,764 had microsatellite motifs, from which 377 were used to design primers, and 302 (80.11%) showed good amplification quality. To analyze transferability, a group of 167 SSRs were tested, and the results showed that they were 82% transferable across at least one species. The highest amplification rates were observed between the species from the Phaseolus (63.7%), Vigna (25.9%), Glycine (19.8%), Medicago (10.2%), Dipterix (6%) and Arachis (1.8%) genera. The average PIC (Polymorphism Information Content) varied from 0.53 for genomic SSRs to 0.47 for EST-SSRs, and the average number of alleles per locus was 4 and 3, respectively. Among the 315 newly tested SSRs in the BJ (BAT93 X Jalo EEP558) population, 24% (76) were polymorphic. The integration of these segregant loci into a framework map composed of 123 previously obtained SSR markers yielded a total of 199 segregant loci, of which 182 (91.5%) were mapped to 14 linkage groups, resulting in a map length of 1,157 cM. Conclusions A total of 302 newly developed EST-SSR markers, showing good amplification quality, are available for the genetic analysis of Phaseolus vulgaris. These markers showed satisfactory rates of transferability, especially between species that have great economic and genomic values. Their diversity was comparable to genomic SSRs, and they were incorporated in the common bean reference genetic map, which constitutes an important contribution to and advance in Phaseolus vulgaris genomic research. PMID:21554695

  6. Tuboimpedance: A New Test of Eustachian Tube Function.

    PubMed

    Smith, Matthew E; Zou, Charlie C; Blythe, Andrew J C; Tysome, James R

    2017-04-01

    Objective Eustachian tube (ET) dysfunction is most frequently caused by a failure of the ET to adequately open; however, there is currently no reliable method of assessing this. Tubomanometry has recently shown good interindividual repeatability as a measure of ET function by measuring middle ear pressure after the application of regulated nasopharyngeal pressures during swallowing. We present the first reports of a novel test: middle ear impedance measurements during standard nasopharyngeal pressure application (tuboimpedance). We assess repeatability in healthy ears and any advantages over tubomanometry. Study Design Exploratory cohort diagnosis study. Setting Tertiary referral center. Subjects Twenty screened, healthy ears (10 volunteers). Methods Tubomanometry and tuboimpedance tests were performed while individuals swallowed with applied nasopharyngeal pressures of 20, 30, 40, and 50 mbar. Eustachian tube opening detection rate and test repeatability (measured by intraclass correlation coefficient [ICC]) for immediate and delayed repeats at each pressure were compared. Results ET opening was detected more frequently using tuboimpedance, with a 100% detection rate using a nasopharyngeal pressure of 30 mbar or more, compared to 88% to 96% with tubomanometry. Detection of ET opening at 20 mbar was possible with tuboimpedance. Repeatability of both tests was mostly strong (ICC >0.7) for both immediate and delayed repeats. Repeatability for the tubomanometry R value was only fair to moderate. Conclusion Tuboimpedance may provide a repeatable measure of ET opening that is easier to perform due to lower nasopharyngeal pressures required and fewer issues with poor ear-probe sealing. Further assessment in patients with different forms of ET dysfunction is required.

  7. Validity and repeatability of inertial measurement units for measuring gait parameters.

    PubMed

    Washabaugh, Edward P; Kalyanaraman, Tarun; Adamczyk, Peter G; Claflin, Edward S; Krishnan, Chandramouli

    2017-06-01

    Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this study was to determine the validity and between-day repeatability of spatiotemporal metrics (gait speed, stance percent, swing percent, gait cycle time, stride length, cadence, and step duration) as measured with the APDM Opal IMUs and Mobility Lab system. We collected data on 39 healthy subjects. Subjects were tested over two days while walking on a standard treadmill, split-belt treadmill, or overground, with IMUs placed in two locations: both feet and both ankles. The spatiotemporal measurements taken with the IMU system were validated against data from an instrumented treadmill, or using standard clinical procedures. Repeatability and minimally detectable change (MDC) of the system was calculated between days. IMUs displayed high to moderate validity when measuring most of the gait metrics tested. Additionally, these measurements appear to be repeatable when used on the treadmill and overground. The foot configuration of the IMUs appeared to better measure gait parameters; however, both the foot and ankle configurations demonstrated good repeatability. In conclusion, the IMU system in this study appears to be both accurate and repeatable for measuring spatiotemporal gait parameters in healthy young adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Medium-sized tandem repeats represent an abundant component of the Drosophila virilis genome.

    PubMed

    Abdurashitov, Murat A; Gonchar, Danila A; Chernukhin, Valery A; Tomilov, Victor N; Tomilova, Julia E; Schostak, Natalia G; Zatsepina, Olga G; Zelentsova, Elena S; Evgen'ev, Michael B; Degtyarev, Sergey K H

    2013-11-09

    Previously, we developed a simple method for carrying out a restriction enzyme analysis of eukaryotic DNA in silico, based on the known DNA sequences of the genomes. This method allows the user to calculate lengths of all DNA fragments that are formed after a whole genome is digested at the theoretical recognition sites of a given restriction enzyme. A comparison of the observed peaks in distribution diagrams with the results from DNA cleavage using several restriction enzymes performed in vitro have shown good correspondence between the theoretical and experimental data in several cases. Here, we applied this approach to the annotated genome of Drosophila virilis which is extremely rich in various repeats. Here we explored the combined approach to perform the restriction analysis of D. virilis DNA. This approach enabled to reveal three abundant medium-sized tandem repeats within the D. virilis genome. While the 225 bp repeats were revealed previously in intergenic non-transcribed spacers between ribosomal genes of D. virilis, two other families comprised of 154 bp and 172 bp repeats were not described. Tandem Repeats Finder search demonstrated that 154 bp and 172 bp units are organized in multiple clusters in the genome of D. virilis. Characteristically, only 154 bp repeats derived from Helitron transposon are transcribed. Using in silico digestion in combination with conventional restriction analysis and sequencing of repeated DNA fragments enabled us to isolate and characterize three highly abundant families of medium-sized repeats present in the D. virilis genome. These repeats comprise a significant portion of the genome and may have important roles in genome function and structural integrity. Therefore, we demonstrated an approach which makes possible to investigate in detail the gross arrangement and expression of medium-sized repeats basing on sequencing data even in the case of incompletely assembled and/or annotated genomes.

  9. Development and application of a dry ultramicrotomy technique for the preparation of galvanneal sheet coatings.

    PubMed

    Barreto, M P; Veillette, R; L'Espérance, G

    1995-07-01

    The formability of galvanneal steel sheets used in the automotive industry is influenced by the presence and distribution of brittle and difficult to distinguish Zn-Fe intermetallics in the coating. Characterization of these intermetallics requires a high spatial resolution technique such as analytical transmission electron microscopy (ATEM). Sample preparation by ion milling is impossible due to iron redeposition, and traditional ultramicrotomy using water affects the coating chemistry. A technique based on dry ultramicrotomy has therefore been developed. To optimize the technique, different parameters (knife angle, cutting medium, thickness setting on the ultramicrotome, cutting speed) have been investigated for the preparation of galvanneal coatings and pure A1 sections. Results show that dry cutting does not affect the coating chemistry but shortens the life of the knife. Knife quality (cleanliness, sharpness and absence of defects) is a major factor to obtain good dry sections. The best results for the more ductile pure A1 are obtained with a 35 degrees knife whilst for the harder galvanneal coating it is recommended to use a 55 degrees knife. These results suggest that the sectioning mechanism for the harder material involves more a cleavage-fracture mechanism whilst a greater amount of shear is involved when sectioning relatively ductile A1. The optimum parameters for sectioning galvanneal coatings are established and results obtained by parallel electron energy loss spectrum imaging and energy dispersive X-ray spectrometry in the TEM are given. This study shows that with a good control of all the sectioning parameters it is possible to obtain good sections repeatedly and rapidly.

  10. Performance analysis of newly developed point-of-care hemoglobinometer (TrueHb) against an automated hematology analyzer (Sysmex XT 1800i) in terms of precision in hemoglobin measurement.

    PubMed

    Srivastava, A; Koul, V; Dwivedi, S N; Upadhyaya, A D; Ahuja, A; Saxena, R

    2015-08-01

    The aim of this study was to evaluate the performance of the newly developed handheld hemoglobinmeter (TrueHb) by comparing its performance against and an automated five-part hematology analyzer, Sysmex counter XT 1800i (Sysmex). Two hundred venous blood samples were subjected through their total hemoglobin evaluation on each device three times. The average of the three readings on each device was considered as their respective device values, that is, TrueHb values and Sysmex values. The two set of values were comparatively analyzed. The repeatability of the performance of TrueHb was also evaluated against Sysmex values. The scatter plot of TrueHb values and Sysmex values showed linear distribution with positive correlations (r = 0.99). The intraclass correlation (ICC) values between the two set of values was found to be 0.995. Regression coefficients through origin, β, was found to be 0.995, with 95% confidence intervals (CI) ranging between 0.9900 and 1.0000. The mean difference in Bland-Altman plots of TrueHb values against the Sysmex values was found to be -0.02, with limits of agreement between -0.777 and 0.732 g/dL. Statistical analysis suggested good repeatability in results of TrueHb, having a low mean CV of 2.22, against 4.44, that of Sysmex values, and 95% confidence interval of 1.99-2.44, against 3.85-5.03, that of Sysmex values. These results suggested a strong positive correlation between the two measurements devices. It is thus concluded that TrueHb is a good point-of-care testing tool for estimating hemoglobin. © 2014 John Wiley & Sons Ltd.

  11. Optical temperature sensing of Er3+/Yb3+ doped LaGdO3 based on fluorescence intensity ratio and lifetime thermometry

    NASA Astrophysics Data System (ADS)

    Siaï, A.; Haro-González, P.; Horchani Naifer, K.; Férid, M.

    2018-02-01

    The investigation of the fluorescence intensity ratio and the lifetime thermometry techniques for two rare earth perovskites-type oxide (LaGdO3:Er3+ and LaGdO3:Er3+/Yb3+) has been carried out. We have demonstrated that the intensity ratio of thermally coupled levels of erbium (2H11/2 and 4S3/2) is temperature dependant in the range from 283 to 393 K. The sensitivity parameter was found to reach a maximum value of 31 × 10-4 K-1 and 34 × 10-4 K-1 at 393 K and the temperature resolution to be equivalent to 1.61 and 3.1 K, for Er3+ and Er3+/Yb3+ doped oxide, respectively. By studying the temperature dependence of the normalized lifetimes in the range from 293 to 348 K, we proved that the sensitivity of the green emission (4S3/2) is higher than the red one (4F9/2) for both samples, and that it increases from 144 × 10-4 K-1 for LaGdO3:Er3+ to 179 × 10-4 K-1 for LaGdO3:Er3+/Yb3+. The thermal coefficients were quite large in comparison to those calculated for different luminescent materials and reported in literature. The repeatability of measurements was tested by performing heating and cooling cycles for both methods and the results show that these optical techniques have a good repeatability performance. Hence, the LaGdO3: Er3+, Yb3+ oxide has a precise and a satisfying sensitivity associated to a good thermal and chemical stability, suggesting that it can be a potential candidate in temperature sensing.

  12. Comparison of the temperature accuracy between smart phone based and high-end thermal cameras using a temperature gradient phantom

    NASA Astrophysics Data System (ADS)

    Klaessens, John H.; van der Veen, Albert; Verdaasdonk, Rudolf M.

    2017-03-01

    Recently, low cost smart phone based thermal cameras are being considered to be used in a clinical setting for monitoring physiological temperature responses such as: body temperature change, local inflammations, perfusion changes or (burn) wound healing. These thermal cameras contain uncooled micro-bolometers with an internal calibration check and have a temperature resolution of 0.1 degree. For clinical applications a fast quality measurement before use is required (absolute temperature check) and quality control (stability, repeatability, absolute temperature, absolute temperature differences) should be performed regularly. Therefore, a calibrated temperature phantom has been developed based on thermistor heating on both ends of a black coated metal strip to create a controllable temperature gradient from room temperature 26 °C up to 100 °C. The absolute temperatures on the strip are determined with software controlled 5 PT-1000 sensors using lookup tables. In this study 3 FLIR-ONE cameras and one high end camera were checked with this temperature phantom. The results show a relative good agreement between both low-cost and high-end camera's and the phantom temperature gradient, with temperature differences of 1 degree up to 6 degrees between the camera's and the phantom. The measurements were repeated as to absolute temperature and temperature stability over the sensor area. Both low-cost and high-end thermal cameras measured relative temperature changes with high accuracy and absolute temperatures with constant deviations. Low-cost smart phone based thermal cameras can be a good alternative to high-end thermal cameras for routine clinical measurements, appropriate to the research question, providing regular calibration checks for quality control.

  13. Acute and repeated dose (28 days) toxicity studies in rats and dogs of recombinant batroxobin, a snake venom thrombin-like enzyme expressed from Pichia pastoris.

    PubMed

    Kim, Ok Hwan; Cho, Kil-Sang; Seomun, Young; Kim, Jong-Tak; Chung, Kwang-Hoe

    2017-04-01

    Recombinant batroxobin is a thrombin-like enzyme of Bothrops atrox moojeni venom. To evaluate its toxicological effect, it was highly expressed in Pichia pastorisand successfully purified to homogeneity from culture broth supernatant following Good Manufacturing Practice (GMP). The maximum tolerated dose of the recombinant batroxobin was examined in Sprague-Dawley (SD) rat and Beagle dogs following Good Laboratory Practice (GLP) regulations. The approximate lethal dose of recombinant batroxobin was 10 National Institute of Health (NIH) u/kg in male and female rats. Slight test substance-related effects were clearly in male and female dogs at more than 10 NIH u/kg. The maximum tolerated dose (MTD) was considered to be greater than 30 NIH u/kg in dogs. To investigate the repeated dose toxicity of batroxobin, the test item was intravenously administered to groups of SD rat and Beagle dog every day for 4 weeks. We observed that all animals survived the duration of the study without any effects on their mortality. There were no effects in both rats and dogs regarding their clinical signs, body weight, food consumption, ophthalmological examination, urinalysis, hematology, clinical chemistry, organ weightand gross post mortem examinations. The no adverse effect level (NOAEL) of recombinant batroxobin for both males and females is considered to be greater than 2.5 NIH u/kgin rats and 1 NIH u/kg in dogs, respectively. No toxic effects were noted in target organs. In conclusion, these results show a favorable preclinical profile and may contribute clinical development of recombinant batroxobin. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. 78 FR 32356 - United States-Korea Free Trade Agreement

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-30

    ... possesses the required origin information; (2) the consistent application of the rules of origin to UKFTA... finding of either (a) repeated unlawful activity or (b) willful presentation of inaccurate origin... that a claim of origin for a textile or apparel good is accurate) or Article 4.3.5 (verification to...

  15. 47 CFR 25.263 - Information sharing requirements for SDARS terrestrial repeater operators.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SDARS licensee and all potentially affected WCS licensees reach a mutual agreement to provide... SDARS licensee and all potentially affected WCS licensees reach a mutual agreement to provide... notice period. (e) Duty to cooperate. SDARS licensees must cooperate in good faith in the selection and...

  16. Flowtables: Program Skeletal Inversion for Defeat of Interprocedural Analysis with Unique Metamorphism

    DTIC Science & Technology

    2015-08-28

    use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the...Hulin, T. Leek, and R. Whelan. Repeatable reverse engineering for the greater good with panda . Technical report, Columbia University, 2014. https

  17. Repeated holdout Cross-Validation of Model to Estimate Risk of Lyme Disease by Landscape Attributes

    EPA Science Inventory

    We previously modeled Lyme disease (LD) risk at the landscape scale; here we evaluate the model's overall goodness-of-fit using holdout validation. Landscapes were characterized within road-bounded analysis units (AU). Observed LD cases (obsLD) were ascertained per AU. Data were ...

  18. Comparison of fatigue analysis approaches for hot-mix asphalt to ensure a state of good repair.

    DOT National Transportation Integrated Search

    2013-10-01

    Fatigue cracking is a primary form of distress in hot-mix asphalt. The long-term nature of fatigue due to repeated : loading and aging and its required tie to pavement structure present challenges in terms of evaluating mixture : resistance. This pro...

  19. Algorithms and Complexity Results for Genome Mapping Problems.

    PubMed

    Rajaraman, Ashok; Zanetti, Joao Paulo Pereira; Manuch, Jan; Chauve, Cedric

    2017-01-01

    Genome mapping algorithms aim at computing an ordering of a set of genomic markers based on local ordering information such as adjacencies and intervals of markers. In most genome mapping models, markers are assumed to occur uniquely in the resulting map. We introduce algorithmic questions that consider repeats, i.e., markers that can have several occurrences in the resulting map. We show that, provided with an upper bound on the copy number of repeated markers and with intervals that span full repeat copies, called repeat spanning intervals, the problem of deciding if a set of adjacencies and repeat spanning intervals admits a genome representation is tractable if the target genome can contain linear and/or circular chromosomal fragments. We also show that extracting a maximum cardinality or weight subset of repeat spanning intervals given a set of adjacencies that admits a genome realization is NP-hard but fixed-parameter tractable in the maximum copy number and the number of adjacent repeats, and tractable if intervals contain a single repeated marker.

  20. Isolation of human simple repeat loci by hybridization selection.

    PubMed

    Armour, J A; Neumann, R; Gobert, S; Jeffreys, A J

    1994-04-01

    We have isolated short tandem repeat arrays from the human genome, using a rapid method involving filter hybridization to enrich for tri- or tetranucleotide tandem repeats. About 30% of clones from the enriched library cross-hybridize with probes containing trimeric or tetrameric tandem arrays, facilitating the rapid isolation of large numbers of clones. In an initial analysis of 54 clones, 46 different tandem arrays were identified. Analysis of these tandem repeat loci by PCR showed that 24 were polymorphic in length; substantially higher levels of polymorphism were displayed by the tetrameric repeat loci isolated than by the trimeric repeats. Primary mapping of these loci by linkage analysis showed that they derive from 17 chromosomes, including the X chromosome. We anticipate the use of this strategy for the efficient isolation of tandem repeats from other sources of genomic DNA, including DNA from flow-sorted chromosomes, and from other species.

  1. Comparison of optical coherence tomography and fundus photography for measuring the optic disc size.

    PubMed

    Neubauer, Aljoscha S; Krieglstein, Tina R; Chryssafis, Christos; Thiel, Martin; Kampik, Anselm

    2006-01-01

    To assess the agreement and repeatability of optic nerve head (ONH) size measurements by optical coherence tomography (OCT) as compared to conventional planimetry of fundus photographs in normal eyes. For comparison with planimetry the absolute size of the ONH of 25 eyes from 25 normal subjects were measured by both OCT and digital fundus photography (Zeiss FF camera 450). Repeatability of automated Stratus OCT measurements were investigated by repeatedly measuring the optic disc in five normal subjects. Mean disc size was 1763 +/- 186 vertically and 1632 +/- 160 microm horizontally on planimetry. On OCT, values of 1772 +/- 317 microm vertically (p = 0.82) and a significantly smaller horizontal diameter of 1492 +/- 302 microm (p = 0.04) were obtained. The 95% limits of agreement were (-546 microm; +527 microm) for vertical and (-502 microm; +782 microm) for horizontal planimetric compared to OCT measurements. In some cases large discrepancies existed. Repeatability of automatic measurements of the optic disc by OCT was moderately good with intra-class correlation coefficients (ICC) of 0.78 horizontally and 0.83 vertically. The coefficient of repeatability indicating instrument precision was 80 microm for horizontal and 168 microm for vertical measurements. OCT can be used to determine optic disc margins in moderate agreement with planimetry in normal subjects. However, in some cases significant disagreement with photographic assessment may occur making manual inspection advisable. Automatic disc detection by OCT is moderately repeatable.

  2. A study on the trinucleotide repeat associated with Huntington`s disease in the Chinese

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bing-wen Soong; Jih-tsuu Wang

    1994-09-01

    Analysis of the polymorphic (CAG)n repeat in the hungingtin gene in the chinese confirmed the presence of an expanded repeat on all Huntington`s disease chromosomes. Measurement of the specific CAG repeat sequence in 34 HD chromosomes from 15 unrelated families and 190 control chromosomes from the Chinese population showed a range from 9 to 29 repeats in normal subjects and 40 to 58 in affected subjects. The size distributions of normal and affected alleles did not overlap. A clear correlation bewteen early onset of symptoms and very high repeat number was seen, but the spread of the age-at-onset in themore » major repeat range producing characteristic HD it too wide to be of diagnostic value. There was also variability in the transmitted repeat size for both sexes in the HD size range. Maternal HD alleles showed a moderate instability with a preponderance of size decrease, while paternal HD alleles had a tendency to increase in repeat size on transmission, the degree of which appeared proportional to the initial size.« less

  3. Environmental stress induces trinucleotide repeat mutagenesis in human cells

    PubMed Central

    Chatterjee, Nimrat; Lin, Yunfu; Santillan, Beatriz A.; Yotnda, Patricia; Wilson, John H.

    2015-01-01

    The dynamic mutability of microsatellite repeats is implicated in the modification of gene function and disease phenotype. Studies of the enhanced instability of long trinucleotide repeats (TNRs)—the cause of multiple human diseases—have revealed a remarkable complexity of mutagenic mechanisms. Here, we show that cold, heat, hypoxic, and oxidative stresses induce mutagenesis of a long CAG repeat tract in human cells. We show that stress-response factors mediate the stress-induced mutagenesis (SIM) of CAG repeats. We show further that SIM of CAG repeats does not involve mismatch repair, nucleotide excision repair, or transcription, processes that are known to promote TNR mutagenesis in other pathways of instability. Instead, we find that these stresses stimulate DNA rereplication, increasing the proportion of cells with >4 C-value (C) DNA content. Knockdown of the replication origin-licensing factor CDT1 eliminates both stress-induced rereplication and CAG repeat mutagenesis. In addition, direct induction of rereplication in the absence of stress also increases the proportion of cells with >4C DNA content and promotes repeat mutagenesis. Thus, environmental stress triggers a unique pathway for TNR mutagenesis that likely is mediated by DNA rereplication. This pathway may impact normal cells as they encounter stresses in their environment or during development or abnormal cells as they evolve metastatic potential. PMID:25775519

  4. Environmental stress induces trinucleotide repeat mutagenesis in human cells.

    PubMed

    Chatterjee, Nimrat; Lin, Yunfu; Santillan, Beatriz A; Yotnda, Patricia; Wilson, John H

    2015-03-24

    The dynamic mutability of microsatellite repeats is implicated in the modification of gene function and disease phenotype. Studies of the enhanced instability of long trinucleotide repeats (TNRs)-the cause of multiple human diseases-have revealed a remarkable complexity of mutagenic mechanisms. Here, we show that cold, heat, hypoxic, and oxidative stresses induce mutagenesis of a long CAG repeat tract in human cells. We show that stress-response factors mediate the stress-induced mutagenesis (SIM) of CAG repeats. We show further that SIM of CAG repeats does not involve mismatch repair, nucleotide excision repair, or transcription, processes that are known to promote TNR mutagenesis in other pathways of instability. Instead, we find that these stresses stimulate DNA rereplication, increasing the proportion of cells with >4 C-value (C) DNA content. Knockdown of the replication origin-licensing factor CDT1 eliminates both stress-induced rereplication and CAG repeat mutagenesis. In addition, direct induction of rereplication in the absence of stress also increases the proportion of cells with >4C DNA content and promotes repeat mutagenesis. Thus, environmental stress triggers a unique pathway for TNR mutagenesis that likely is mediated by DNA rereplication. This pathway may impact normal cells as they encounter stresses in their environment or during development or abnormal cells as they evolve metastatic potential.

  5. Genetic characterization of UCS region of Pneumocystis jirovecii and construction of allelic profiles of Indian isolates based on sequence typing at three regions.

    PubMed

    Gupta, Rashmi; Mirdha, Bijay Ranjan; Guleria, Randeep; Kumar, Lalit; Luthra, Kalpana; Agarwal, Sanjay Kumar; Sreenivas, Vishnubhatla

    2013-01-01

    Pneumocystis jirovecii is an opportunistic pathogen that causes severe pneumonia in immunocompromised patients. To study the genetic diversity of P. jirovecii in India the upstream conserved sequence (UCS) region of Pneumocystis genome was amplified, sequenced and genotyped from a set of respiratory specimens obtained from 50 patients with a positive result for nested mitochondrial large subunit ribosomal RNA (mtLSU rRNA) PCR during the years 2005-2008. Of these 50 cases, 45 showed a positive PCR for UCS region. Variations in the tandem repeats in UCS region were characterized by sequencing all the positive cases. Of the 45 cases, one case showed five repeats, 11 cases showed four repeats, 29 cases showed three repeats and four cases showed two repeats. By running amplified DNA from all these cases on a high-resolution gel, mixed infection was observed in 12 cases (26.7%, 12/45). Forty three of 45 cases included in this study had previously been typed at mtLSU rRNA and internal transcribed spacer (ITS) region by our group. In the present study, the genotypes at those two regions were combined with UCS repeat patterns to construct allelic profiles of 43 cases. A total of 36 allelic profiles were observed in 43 isolates indicating high genetic variability. A statistically significant association was observed between mtLSU rRNA genotype 1, ITS type Ea and UCS repeat pattern 4. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Chemical synthesis of the tetrasaccharide repeating unit of the O-polysaccharide isolated from Azospirillum brasilense SR80.

    PubMed

    Sarkar, Vikramjit; Mukhopadhyay, Balaram

    2015-04-10

    A linear strategy has been developed for the synthesis of the tetrasaccharide repeating unit of the O-polysaccharide from Azospirillum brasilense SR80. Stepwise glycosylation of the rationally protected thioglycoside donors activated by NIS in the presence of La(OTf)3 furnished the target tetrasaccharide. The glycosylation reactions resulted in the formation of the desired linkage with absolute stereoselectivity and afforded the required derivatives in good to excellent yields. The phthalimido group has been used as the precursor of the desired acetamido group to meet the requirement of 1,2-trans glycosidic linkage. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. DNA-binding proteins from marine bacteria expand the known sequence diversity of TALE-like repeats

    PubMed Central

    de Lange, Orlando; Wolf, Christina; Thiel, Philipp; Krüger, Jens; Kleusch, Christian; Kohlbacher, Oliver; Lahaye, Thomas

    2015-01-01

    Transcription Activator-Like Effectors (TALEs) of Xanthomonas bacteria are programmable DNA binding proteins with unprecedented target specificity. Comparative studies into TALE repeat structure and function are hindered by the limited sequence variation among TALE repeats. More sequence-diverse TALE-like proteins are known from Ralstonia solanacearum (RipTALs) and Burkholderia rhizoxinica (Bats), but RipTAL and Bat repeats are conserved with those of TALEs around the DNA-binding residue. We study two novel marine-organism TALE-like proteins (MOrTL1 and MOrTL2), the first to date of non-terrestrial origin. We have assessed their DNA-binding properties and modelled repeat structures. We found that repeats from these proteins mediate sequence specific DNA binding conforming to the TALE code, despite low sequence similarity to TALE repeats, and with novel residues around the BSR. However, MOrTL1 repeats show greater sequence discriminating power than MOrTL2 repeats. Sequence alignments show that there are only three residues conserved between repeats of all TALE-like proteins including the two new additions. This conserved motif could prove useful as an identifier for future TALE-likes. Additionally, comparing MOrTL repeats with those of other TALE-likes suggests a common evolutionary origin for the TALEs, RipTALs and Bats. PMID:26481363

  8. Randomized Trial Comparing Amniotic Membrane Transplantation with Lamellar Corneal Graft for the Treatment of Corneal Thinning.

    PubMed

    de Farias, Charles C; Allemann, Norma; Gomes, José Á P

    2016-04-01

    There are few studies comparing different surgical procedures for the treatment of corneal thinning. Lamellar corneal transplantation (LCT) has been reported to be efficient, but its results can be jeopardized by allograft rejection, opacification, or high astigmatism. Amniotic membrane transplantation (AMT) has been considered a good alternative, but it is not as resistant as LCT and the tissue can be reabsorbed after surgery. A prospective, randomized, interventional, and comparative study of consecutive patients with corneal thinning over 6 months was performed. Ophthalmological examination was performed before transplant surgery and then repeated 1, 7, 15, 30, 90, and 180 days after surgery and ultrasound biomicroscopy was performed before and then 30, 90, and 180 days after surgery to assess corneal thinning. Herpes simplex infection was the main cause of corneal thinning (9 eyes), followed by surgery (cataract, glaucoma, 5 cases), rheumatoid arthritis (1), chemical burn (1), perforating trauma (1), previous band keratopathy treatment (1), and Stevens-Johnson syndrome (1). Although all patients showed significant increase in final thickness in the area of thinning, it was higher in those submitted to LCT at 180 days postoperatively. Regardless of the surgical technique, all patients showed epithelialization. Patients undergoing AMT showed an 89% decrease in neovascularization. Final corrected distance visual acuity was better in patients submitted to AMT. LCT proved to be the best option for treating corneal thinning. AMT represents an alternative that allows good visual recovery but does not restore corneal thickness as efficiently as LCT.

  9. Reliability of a portable device for the detection of sleep bruxism.

    PubMed

    Deregibus, Andrea; Castroflorio, Tommaso; Bargellini, Andrea; Debernardi, Cesare

    2014-11-01

    The aim of the study was to assess the repeatability in detecting sleep bruxism (SB) episodes by combined surface electromyography and heart rate (HR) signals recorded by a compact portable device (Bruxoff®). SB episodes are preceded by a sudden HR change. Thus, HR detection increases the precision of automatic detection of SB. Ten healthy subjects (five women and five men; 30.2 ± 11.02 years) were selected for the study. Rhythmic masseter muscle activities, constituting the basic pattern of SB, were detected during three nights of recording during three different weeks with the Bruxoff device. The two-way ANOVA was not significant for SB episodes per night, SB episodes per hour, and heart frequency: no significant differences were observed during the three different nights of recording for each of the abovementioned variables (P > 0.05). The intraclass correlation coefficient showed a good reproducibility for SB episodes per night (69 %), SB per hour (74 %), and heart frequency (82 %). A poor reproducibility was revealed for the number of masseter contractions (53 %). The Pearson analysis showed the absence of a significant correlation between the number of masseter contractions per night and the number of SB episodes per night (r = -0.02, P = 0.91). The Bruxoff device showed a good reproducibility of measurements of sleep bruxism episodes over time. These findings are important in the light of the need for simple and reliable portable devices for the diagnosis of SB both in the clinical and research settings.

  10. Hydrous iron oxide modified diatomite as an active filtration medium for phosphate capture.

    PubMed

    Wang, Zhe; Lin, Yan; Wu, Deyi; Kong, Hainan

    2016-02-01

    A simple method to functionalize diatomite with hydrous iron oxide was attempted and its performance as a new active filtration material to remove and recover phosphate from water was investigated under varying solution conditions. The Langmuir phosphate adsorption capacity increased from 0.6 mgP/g for raw diatomite to 4.89, 14.71, 25.02 mgP/g for hydrous iron oxide modified diatomite (HIOMD), depending on the amount of iron loaded. Loading of hydrous iron oxide caused the increase in true and bulk density and a decline in filtration rate, but to a lesser extent. It was shown that the HIOMD product with suitable iron content could retain a good filtration performance with a greatly increased adsorption capacity for phosphate. The phosphate adsorption increased by decreasing pH and by increasing ionic strength at high pH levels. The adsorption process was interpreted by ligand exchange. Coexisting oxyanions of sulfate, nitrate, citrate, carbonate, silicate and humic acid showed different effects on phosphate fixation but it was presumed that their influence at their concentrations and pH levels commonly encountered in effluent or natural waters was limited, i.e., HIOMD had a reasonably good selectivity. Results in repeated adsorption, desorption and regeneration experiment showed that the adsorbed phosphate could be recovered and the material could be reused after regeneration. The column test showed that HIOMD could be potentially utilized as an adsorption filtration medium for phosphate removal and recovery from water. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Investigation of a Quadruplex-Forming Repeat Sequence Highly Enriched in Xanthomonas and Nostoc sp.

    PubMed

    Rehm, Charlotte; Wurmthaler, Lena A; Li, Yuanhao; Frickey, Tancred; Hartig, Jörg S

    2015-01-01

    In prokaryotes simple sequence repeats (SSRs) with unit sizes of 1-5 nucleotides (nt) are causative for phase and antigenic variation. Although an increased abundance of heptameric repeats was noticed in bacteria, reports about SSRs of 6-9 nt are rare. In particular G-rich repeat sequences with the propensity to fold into G-quadruplex (G4) structures have received little attention. In silico analysis of prokaryotic genomes show putative G4 forming sequences to be abundant. This report focuses on a surprisingly enriched G-rich repeat of the type GGGNATC in Xanthomonas and cyanobacteria such as Nostoc. We studied in detail the genomes of Xanthomonas campestris pv. campestris ATCC 33913 (Xcc), Xanthomonas axonopodis pv. citri str. 306 (Xac), and Nostoc sp. strain PCC7120 (Ana). In all three organisms repeats are spread all over the genome with an over-representation in non-coding regions. Extensive variation of the number of repetitive units was observed with repeat numbers ranging from two up to 26 units. However a clear preference for four units was detected. The strong bias for four units coincides with the requirement of four consecutive G-tracts for G4 formation. Evidence for G4 formation of the consensus repeat sequences was found in biophysical studies utilizing CD spectroscopy. The G-rich repeats are preferably located between aligned open reading frames (ORFs) and are under-represented in coding regions or between divergent ORFs. The G-rich repeats are preferentially located within a distance of 50 bp upstream of an ORF on the anti-sense strand or within 50 bp from the stop codon on the sense strand. Analysis of whole transcriptome sequence data showed that the majority of repeat sequences are transcribed. The genetic loci in the vicinity of repeat regions show increased genomic stability. In conclusion, we introduce and characterize a special class of highly abundant and wide-spread quadruplex-forming repeat sequences in bacteria.

  12. Investigation of a Quadruplex-Forming Repeat Sequence Highly Enriched in Xanthomonas and Nostoc sp.

    PubMed Central

    Rehm, Charlotte; Wurmthaler, Lena A.; Li, Yuanhao; Frickey, Tancred; Hartig, Jörg S.

    2015-01-01

    In prokaryotes simple sequence repeats (SSRs) with unit sizes of 1–5 nucleotides (nt) are causative for phase and antigenic variation. Although an increased abundance of heptameric repeats was noticed in bacteria, reports about SSRs of 6–9 nt are rare. In particular G-rich repeat sequences with the propensity to fold into G-quadruplex (G4) structures have received little attention. In silico analysis of prokaryotic genomes show putative G4 forming sequences to be abundant. This report focuses on a surprisingly enriched G-rich repeat of the type GGGNATC in Xanthomonas and cyanobacteria such as Nostoc. We studied in detail the genomes of Xanthomonas campestris pv. campestris ATCC 33913 (Xcc), Xanthomonas axonopodis pv. citri str. 306 (Xac), and Nostoc sp. strain PCC7120 (Ana). In all three organisms repeats are spread all over the genome with an over-representation in non-coding regions. Extensive variation of the number of repetitive units was observed with repeat numbers ranging from two up to 26 units. However a clear preference for four units was detected. The strong bias for four units coincides with the requirement of four consecutive G-tracts for G4 formation. Evidence for G4 formation of the consensus repeat sequences was found in biophysical studies utilizing CD spectroscopy. The G-rich repeats are preferably located between aligned open reading frames (ORFs) and are under-represented in coding regions or between divergent ORFs. The G-rich repeats are preferentially located within a distance of 50 bp upstream of an ORF on the anti-sense strand or within 50 bp from the stop codon on the sense strand. Analysis of whole transcriptome sequence data showed that the majority of repeat sequences are transcribed. The genetic loci in the vicinity of repeat regions show increased genomic stability. In conclusion, we introduce and characterize a special class of highly abundant and wide-spread quadruplex-forming repeat sequences in bacteria. PMID:26695179

  13. The long-term reliability of static and dynamic quantitative sensory testing in healthy individuals.

    PubMed

    Marcuzzi, Anna; Wrigley, Paul J; Dean, Catherine M; Adams, Roger; Hush, Julia M

    2017-07-01

    Quantitative sensory tests (QSTs) have been increasingly used to investigate alterations in somatosensory function in a wide range of painful conditions. The interpretation of these findings is based on the assumption that the measures are stable and reproducible. To date, reliability of QST has been investigated for short test-retest intervals. The aim of this study was to investigate the long-term reliability of a multimodal QST assessment in healthy people, with testing conducted on 3 occasions over 4 months. Forty-two healthy people were enrolled in the study. Static and dynamic tests were performed, including cold and heat pain threshold (CPT, HPT), mechanical wind-up [wind-up ratio (WUR)], pressure pain threshold (PPT), 2-point discrimination (TPD), and conditioned pain modulation (CPM). Systematic bias, relative reliability and agreement were analysed using repeated measure analysis of variance, intraclass correlation coefficients (ICCs3,1) and SE of the measurement (SEM), respectively. Static QST (CPT, HPT, PPT, and TPD) showed good-to-excellent reliability (ICCs: 0.68-0.90). Dynamic QST (WUR and CPM) showed poor-to-good reliability (ICCs: 0.35-0.61). A significant linear decrease over time was observed for mechanical QST at the back (PPT and TPD) and for CPM (P < 0.01). Static QST were stable over a period of 4 months; however, a small systematic decrease over time has been observed for mechanical QST. Dynamic QST showed considerable variability over time; in particular, CPM using PPT as the test stimulus did not show adequate reliability, suggesting that this test paradigm may be less useful for monitoring individuals over time.

  14. Fabricate Optical Microfiber by Using Flame Brushing Technique and Coated with Polymer Polyaniline for Sensing Application

    NASA Astrophysics Data System (ADS)

    Razak, N. A.; Hamida, B. A.; Irawati, N.; Habaebi, M. H.

    2017-06-01

    Adiabaticity is one of the essential criteria in producing good fabricated tapered fibers. Good tapered fibers can be use in sensor application such as humidity sensor, temperature sensor and refractive index sensor. In this paper, good tapering silica fiber is produced by using flame brushing technique and then, the microfiber is coated with polymer Polyaniline (PAni) to sense different type of alcohols with different concentrations. The outcome of this experiment gives excellent repeatability in the detection of alcohol sensing with a sensitivity of 0.1332 μW/% and a resolution of 3.764%. In conclusion, conducting polymer coated optical microfiber sensor for alcohol detection with low cost, effective and simple set-up was successfully achieved in this study.

  15. [HPLC specific chromatogram of Dendrobium officinale].

    PubMed

    Yan, Mei-Qiu; Chen, Su-Hong; Lv, Gui-Yuan; Zhou, Gui-Fen; Liu, Xia

    2013-02-01

    To establish the method of specific chromatogram analysis of ether extract of Dendrobium officinale for identification of D. officinale. Chromatographic separation was carried out at 30 degrees C on an Ultimate C18 column (4.6 mm x 250 mm, 5 microm) eluted with methanol and water containing 0.2% phosphoric acid in a gradient elution at a flow rate of 1.0 mL x min(-1). The detection wavelength was set at 280 nm. The similarity evaluation system for chromatographic fingerprint of NPC (National Pharmacopoeia Committee) was adopted to specific chromatogram construction. The HPLC specific chromatogram of D. officinale was constructed with 6 common specific chromatographic peaks including naringenin as a reference peak. The method shows good precision and repeatability of relative retention time. It can be used to identify D. officinale.

  16. Novel Low-Cost Sensor for Human Bite Force Measurement

    PubMed Central

    Fastier-Wooller, Jarred; Phan, Hoang-Phuong; Dinh, Toan; Nguyen, Tuan-Khoa; Cameron, Andrew; Öchsner, Andreas; Dao, Dzung Viet

    2016-01-01

    This paper presents the design and development of a low cost and reliable maximal voluntary bite force sensor which can be manufactured in-house by using an acrylic laser cutting machine. The sensor has been designed for ease of fabrication, assembly, calibration, and safe use. The sensor is capable of use within an hour of commencing production, allowing for rapid prototyping/modifications and practical implementation. The measured data shows a good linear relationship between the applied force and the electrical resistance of the sensor. The output signal has low drift, excellent repeatability, and a large measurable range of 0 to 700 N. A high signal-to-noise response to human bite forces was observed, indicating the high potential of the proposed sensor for human bite force measurement. PMID:27509496

  17. "Fight the poisoners of the people!" The beginnings of food regulation in São Paulo and Rio de Janeiro, 1889-1930.

    PubMed

    Brinkmann, Sören

    2017-01-01

    For urban Brazil, the First World War triggered a dramatic food crisis that brought with it a massive increase in falsified goods and led to an uproar among the general public. Critics targeted the health authorities, who were evidently unable to suppress these frauds. This text spans the First Republic period and shows that since its proclamation the issue of regulating the food trade was part of health policies, but implementation was repeatedly delayed because of other priorities. This situation only changed with the health reforms of the early 1920s, which allows us to identify the First World War food crisis as a decisive point for the Brazilian state to take responsibility in this area.

  18. Determination of ethylenediaminetetraacetic acid in sea water by solid-phase extraction and high-performance liquid chromatography.

    PubMed

    Kemmei, Tomoko; Kodama, Shuji; Fujishima, Hironori; Yamamoto, Atsushi; Inoue, Yoshinori; Hayakawa, Kazuichi

    2012-01-04

    The chelating agent EDTA is widely used, and as a result is showing up widely in the aquatic environment. Here we describe a preconcentration procedure for measuring EDTA concentration in sea water samples by HPLC. The procedure consists of forming an Fe(III) complex followed by solid-phase extraction using an activated carbon cartridge. After the preconcentration, EDTA was quantified by HPLC with ultraviolet detection (260 nm). The enrichment permitted the determination of EDTA at concentrations as low as 1 nM. Good recoveries were obtained for both brackish and full-strength sea water with high repeatability (RSD<6%). The method was applied to sea water samples taken from near the mouth of the Oyabe River in Japan. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Avoiding short circuits from zinc metal dendrites in anode by backside-plating configuration

    PubMed Central

    Higashi, Shougo; Lee, Seok Woo; Lee, Jang Soo; Takechi, Kensuke; Cui, Yi

    2016-01-01

    Portable power sources and grid-scale storage both require batteries combining high energy density and low cost. Zinc metal battery systems are attractive due to the low cost of zinc and its high charge-storage capacity. However, under repeated plating and stripping, zinc metal anodes undergo a well-known problem, zinc dendrite formation, causing internal shorting. Here we show a backside-plating configuration that enables long-term cycling of zinc metal batteries without shorting. We demonstrate 800 stable cycles of nickel–zinc batteries with good power rate (20 mA cm−2, 20 C rate for our anodes). Such a backside-plating method can be applied to not only zinc metal systems but also other metal-based electrodes suffering from internal short circuits. PMID:27263471

  20. A Fast and Easily-Realized Concentration Sensor for Binary Gas Mixtures and Its Design Analysis.

    PubMed

    Guan, Yu; Lu, Song; Zhang, Dan; Hu, Yang; Yuan, Wei

    2018-04-19

    A low-cost and easily-realized sensing device used for the detection of gas mixtures at different concentrations is presented. Its sensing part includes a small critical nozzle, a laminar structure, and a differential pressure sensor. When gas flows through the laminar structure, there is a pressure drop between both ends of it, and for different components of gas, the pressure drop is different. Based on this feature, the concentration detection is achieved. Concentration tests for two types of fire extinguishing agents CBrF₃ and C₃HF₇ are presented. The results show the characteristics of fast response/recovery time, high accuracy, and good repeatability. Based on the theoretical analysis, the effects of the design parameters on the sensing performance to concentration detection are discussed in detail.

  1. Introduction to Blueweb: A Decentralized Scatternet Formation Algorithm for Bluetooth Ad Hoc Networks

    NASA Astrophysics Data System (ADS)

    Yu, Chih-Min; Huang, Chia-Chi

    In this letter, a decentralized scatternet formation algorithm called Bluelayer is proposed. First, Bluelayer uses a designated root to construct a tree-shaped subnet and propagates an integer variable k1 called counter limit as well as a constant k in its downstream direction to determine new roots. Then each new root asks its upstream master to start a return connection procedure to convert the tree-shaped subnet into a web-shaped subnet for its immediate upstream root. At the same time, each new root repeats the same procedure as the root to build its own subnet until the whole scatternet is formed. Simulation results show that Bluelayer achieves good network scalability and generates an efficient scatternet configuration for various sizes of Bluetooth ad hoc network.

  2. GDP: A new source for shallow high-resolution seismic exploration

    NASA Astrophysics Data System (ADS)

    Rashed, Mohamed A.

    2009-06-01

    Gas-Driven Piston (GDP) is a new source for shallow seismic exploration. This source works by igniting a small amount of gas inside a closed chamber connected to a vertical steel cylinder. The gas explosion drives a steel piston, mounted inside the cylinder, downward so that the piston's thick head hits a steel base at the end of the cylinder generating a strong shock wave into the ground. Experimental field tests conducted near Ismailia, Egypt, prove that the portable, inexpensive and environmentally benign GDP generates stronger seismic waves than the sledgehammer that is commonly used in shallow seismic exploration. Tests also show that GDP is a highly repeatable and controllable and that its seismic waves contain a good amount of high frequencies which makes the GDP an excellent source for shallow seismic exploration.

  3. Low-Temperature Carrier Transport in Ionic-Liquid-Gated Hydrogen-Terminated Silicon

    NASA Astrophysics Data System (ADS)

    Sasama, Yosuke; Yamaguchi, Takahide; Tanaka, Masashi; Takeya, Hiroyuki; Takano, Yoshihiko

    2017-11-01

    We fabricated ionic-liquid-gated field-effect transistors on the hydrogen-terminated (111)-oriented surface of undoped silicon. Ion implantation underneath electrodes leads to good ohmic contacts, which persist at low temperatures down to 1.4 K. The sheet resistance of the channel decreases by more than five orders of magnitude as the gate voltage is changed from 0 to -1.6 V at 220 K. This is caused by the accumulation of hole carriers. The sheet resistance shows thermally activated behavior at temperatures below 10 K, which is attributed to hopping transport of the carriers. The activation energy decreases towards zero with increasing carrier density, suggesting the approach to an insulator-metal transition. We also report the variation of device characteristics induced by repeated sweeps of the gate voltage.

  4. Enhanced glucose biosensor properties of gold nanoparticle-decorated ZnO nanorods

    NASA Astrophysics Data System (ADS)

    Wang, Zi-Hao; Yang, Chih-Chiang; Su, Yan-Kuin; Ruand, Jian-Long

    2017-04-01

    As new materials have been reported and more knowledge on detailed mechanism of glucose oxidation has been unveiled, the non-enzymatic glucose sensor keeps coming closer to practical applications. Nanostructures with higher surface specific area has great potential applications in sensing devices ZnO nanoords were synthesized in a hydrothermal method using simply available laboratory chemicals. Results showed that as-synthesized Gold Nanoparticle-decorated ZnO Nanorods possessing higher specific surface area, significantly increased the non-enzyme efficiency which in turn improved the sensing performances. The electrode also demonstrated excellent performance in sensing glucose concentration with remarkable sensitivity (46.6 μA/mM-cm2) and good repeatability. This work is expected to open a new avenue to fabricate non-enzymatic electrochemical sensors of glucose involving co-mediating.

  5. Avoiding short circuits from zinc metal dendrites in anode by backside-plating configuration

    NASA Astrophysics Data System (ADS)

    Higashi, Shougo; Lee, Seok Woo; Lee, Jang Soo; Takechi, Kensuke; Cui, Yi

    2016-06-01

    Portable power sources and grid-scale storage both require batteries combining high energy density and low cost. Zinc metal battery systems are attractive due to the low cost of zinc and its high charge-storage capacity. However, under repeated plating and stripping, zinc metal anodes undergo a well-known problem, zinc dendrite formation, causing internal shorting. Here we show a backside-plating configuration that enables long-term cycling of zinc metal batteries without shorting. We demonstrate 800 stable cycles of nickel-zinc batteries with good power rate (20 mA cm-2, 20 C rate for our anodes). Such a backside-plating method can be applied to not only zinc metal systems but also other metal-based electrodes suffering from internal short circuits.

  6. Neurophysiological evidence for transfer appropriate processing of memory: processing versus feature similarity.

    PubMed

    Schendan, Haune E; Kutas, Malra

    2007-08-01

    Transfer appropriate processing (TAP) accounts propose that memory is a function of the degree to which the same neural processes transfer appropriately from the study experience to the memory test. However, in prior research, study and test stimuli were often similar physically. In two experiments, event-related brain potentials (ERPs) were recorded to fragmented objects during an indirect memory test to isolate transfer of a specific perceptual process from overlap of physical features between experiences. An occipitotemporoparietal P2(00) at 200 msec showed implicit memory effects only when similar perceptual grouping processes of good continuation were repeatedly engaged-despite physical feature differences--as TAP accounts hypothesize. This result provides direct neurophysiological evidence for the critical role of process transfer across experiences for memory.

  7. Threshold Switching Characteristics of Nb/NbO 2 /TiN Vertical Devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yuhan; Comes, Ryan B.; Wolf, Stuart A.

    2016-01-01

    Nb/NbO2/TiN vertical structures were synthesized in-situ and patterned to devices with different contact areas. The devices exhibited threshold resistive switching with minimal hysteresis and a small EThreshold (60~90 kV/cm). The switching behavior was unipolar, and demonstrated good repeatability. A less sharp but still sizable change in the device resistance was observed up to 150 °C. It was found that the resistive switching without Nb capping layer exhibited the hysteretic behavior and much larger EThreshold (~250 kV/cm) likely due to a 2-3 nm surface Nb2O5 layer. The stable threshold switching behavior well above room temperature shows the potential applications of thismore » device as an electronic switch.« less

  8. [Evolution of the technique of arthroscopic reinsertion of the rotator cuff. Our experience from the years 1998 to 2008].

    PubMed

    Holibka, R; Neoral, P; Kalina, R; Radová, L; Gallo, J

    2012-01-01

    A rotator cuff tear is a relatively frequent cause of pain and restricted motion of the shoulder. Some orthopaedists believe that any attempt at rotator cuff reconstruction will fail. The aim of this paper is to present our experience with arthroscopic reconstruction of rotator cuff tears. Between January 1998 and December 2008, 319 patients with an early diagnosis of rotator cuff rupture were treated. The group included 67 women and 252 men, with an average age of 37 years (range, 24 to 71 years) at the time of surgery. The patients indicated for arthroscopic reconstruction had to show free motion of the shoulder, had a full thickness tear up to 3 cm in size in the sagittal plane and a Patte stage 2 tear in the frontal plane at the maximum. The outcome of surgery was evaluated at one year of follow-up and included the patient's self-assessment, modified UCLA score and incidence of complications. The probability of failure was calculated as an odds ratio of an implant failure to failure of the other implants and the probability of repeat surgery in a given implant was calculated as a relative risk in relation to the other implants. The average operative time was 52 minutes (range, 25 to 85); the average UCLA score increased from 10 to 31 points (p<0.00001). An excellent or a good result was achieved in 80% of the patients. Rotator cuff reconstruction failed in 32 patients (11%), of whom 22 (7.6%) underwent revision surgery. The failure was due to migration of rotator cuff anchors or thread failure in 14 patients (14/32; 44%). The GII anchors showed the highest risk of failure, with the odds ratio of 5.55 (95 % CI, 2.22 to 13.84) for mechanical failure of the method and a relative risk of revision surgery of 7.62 (95% CI, 2.86 to 20.27). For comparison, the RC anchors had the odds ratio for mechanical failure equal to 0.55 (95 % CI, 0.25 to 1.24) and the relative risk of repeat surgery equal to 0.41 (95% CI, 0.12 to 1.43). In addition, 18 complications were recorded. The frequency of deep wound infection was 0.7% (2/319). Six patients (2.1%) required repeat surgery for symptomatic bursitis and adhesive capsulitis. A recent meta-analysis has found no significant difference between the results of surgical rotator cuff reconstruction and its conservative treatment. We do not support this view but present here evidence that, when certain conditions are fulfilled, arthroscopic reconstruction can produce a very good clinical outcome. The arthroscopic reconstruction of a rotator cuff tears results in a marked relief of pain and improved joint function. An ideal candidate for this treatment should show passive free motion at the shoulder joint, no clinical signs of bursitis, and mobilisable tendon stumps of the torn rotator cuff. In addition, these patients should be highly motivated for post-operative rehabilitation. A suture device was most effective in rotator cuff repair. For good fixation into the bone it is recommended to use special implants that have a minimal risk of dislodgement or anchor thread failure.

  9. Terrestrial laser scanning and a degenerated cylinder model to determine gross morphological change of cadavers under conditions of natural decomposition.

    PubMed

    Zhang, Xiao; Glennie, Craig L; Bucheli, Sibyl R; Lindgren, Natalie K; Lynne, Aaron M

    2014-08-01

    Decomposition can be a highly variable process with stages that are difficult to quantify. Using high accuracy terrestrial laser scanning a repeated three-dimensional (3D) documentation of volumetric changes of a human body during early decomposition is recorded. To determine temporal volumetric variations as well as 3D distribution of the changed locations in the body over time, this paper introduces the use of multiple degenerated cylinder models to provide a reasonable approximation of body parts against which 3D change can be measured and visualized. An iterative closest point algorithm is used for 3D registration, and a method for determining volumetric change is presented. Comparison of the laser scanning estimates of volumetric change shows good agreement with repeated in-situ measurements of abdomen and limb circumference that were taken diurnally. The 3D visualizations of volumetric changes demonstrate that bloat is a process with a beginning, middle, and end rather than a state of presence or absence. Additionally, the 3D visualizations show conclusively that cadaver bloat is not isolated to the abdominal cavity, but also occurs in the limbs. Detailed quantification of the bloat stage of decay has the potential to alter how the beginning and end of bloat are determined by researchers and can provide further insight into the effects of the ecosystem on decomposition. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. An electrochemical immunosensor for cardiac Troponin I using electrospun carboxylated multi-walled carbon nanotube-whiskered nanofibres.

    PubMed

    Rezaei, Babak; Shoushtari, Ahmad Mousavi; Rabiee, Mohammad; Uzun, Lokman; Mak, Wing Cheung; Turner, Anthony P F

    2018-05-15

    A sandwich-type nanostructured immunosensor based on carboxylated multi-walled carbon nanotube (CMWCNT)-embedded whiskered nanofibres (WNFs) was developed for detection of cardiac Troponin I (cTnI). WNFs were directly fabricated on glassy carbon electrodes (GCE) by removing the sacrificial component (polyethylene glycol, PEG) after electrospinning of polystyrene/CMWCNT/PEG nanocomposite nanofibres, and utilised as a transducer layer for enzyme-labeled amperometric immunoassay of cTnI. The whiskered segments of CMWCNTs were activated and utilised to immobilise anti-cTnT antibodies. It was observed that the anchored CMWCNTs within the nanofibres were suitably stabilised with excellent electrochemical repeatability. A sandwich-type immuno-complex was formed between cTnI and horseradish peroxidase-conjugated anti-cTnI (HRP-anti-cTnI). The amperometric responses of the immunosensor were studied using cyclic voltammetry (CV) through an enzymatic reaction between hydrogen peroxide and HRP conjugated to the secondary antibody. The nanostructured immunosensor delivered a wide detection range for cTnI from the clinical borderline for a normal person (0.5-2ngmL -1 ) to the concentration present in myocardial infarction patients (> 20ngmL -1 ), with a detection limit of ~ 0.04ngmL -1 . It also showed good reproducibility and repeatability for three different cTnI concentration (1, 10 and 25ngmL -1 ) with satisfactory relative standard deviations (RSD). Hence, the proposed nanostructured immunosensor shows potential for point-of-care testing. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Validation of a Hartmann-Moiré wavefront sensor with large dynamic range.

    PubMed

    Wei, Xin; Van Heugten, Tony; Thibos, Larry

    2009-08-03

    Our goal was to validate the accuracy, repeatability, sensitivity, and dynamic range of a Hartmann-Moiré (HM) wavefront sensor (PixelOptics, Inc.) designed for ophthalmic applications. Testing apparatus injected a 4 mm diameter monochromatic (532 nm) beam of light into the wavefront sensor for measurement. Controlled amounts of defocus and astigmatism were introduced into the beam with calibrated spherical (-20D to + 18D) and cylindrical (-8D to + 8D) lenses. Repeatability was assessed with three repeated measurements within a 2-minute period. Correlation coefficients between mean wavefront measurements (n = 3) and expected wavefront vergence for both sphere and cylinder lenses were >0.999. For spherical lenses, the sensor was accurate to within 0.1D over the range from -20D to + 18D. For cylindrical lenses, the sensor was accurate to within 0.1D over the range from -8D to + 8D. The primary limitation to demonstrating an even larger dynamic range was the increasingly critical requirements for optical alignment. Sensitivity to small changes of vergence was constant over the instrument's full dynamic range. Repeatability of measurements for fixed condition was within 0.01D. The Hartmann-Moiré wavefront sensor measures defocus and astigmatism accurately and repeatedly with good sensitivity over a large dynamic range required for ophthalmic applications.

  12. Repeatability of knee impulsive loading measurements with skin-mounted accelerometers and lower limb surface electromyographic recordings during gait in knee osteoarthritic and asymptomatic individuals

    PubMed Central

    Lyytinen, T.; Bragge, T.; Hakkarainen, M.; Liikavainio, T.; Karjalainen, P.A.; Arokoski, J.P.

    2016-01-01

    Objectives: To determine the repeatability of knee joint impulsive loading measurements with skin-mounted accelerometers (SMAs) and lower limb surface electromyography (EMG) recordings during gait. Methods: Triaxial SMA and EMG from 4 muscles during level and stair walking in nine healthy and nine knee osteoarthritis (OA) subjects were used. The initial peak acceleration (IPA), root mean square (RMS), maximal acceleration transient rate (ATRmax) and mean EMG activity (EMGact) were calculated. The coefficient of variation (CV) and the intraclass correlation coefficient (ICC) were calculated to measure repeatability. Results: The CV and ICC of RMS accelerations ranged from 4.9% to 10.9% and from 0.69 to 0.96 in both study groups during level walking. The CV and ICC of IPA and ATRmax varied from 7.7% to 14.2% and from 0.85 to 0.99 during level and stairs up walking in healthy subjects. The CV and ICC of EMGact ranged from 8.3% to 31.7% and from 0.16 to 0.97 in both study groups. Conclusions: RMS accelerations exhibited good repeatability during walking in healthy and knee OA subjects. The repeatability of EMG measurements was acceptable in healthy subjects depending on the measured muscles. PMID:26944825

  13. High-Intensity Small-Sided Games versus Repeated Sprint Training in Junior Soccer Players.

    PubMed

    Eniseler, Niyazi; Şahan, Çağatay; Özcan, Ilker; Dinler, Kıvanç

    2017-12-01

    The aim of this study was to compare the effects of high-intensity small-sided games training (SSGT) versus repeated-sprint training (RST) on repeated-sprint ability (RSA), soccer specific endurance performance and short passing ability among junior soccer players. The junior soccer players were recruited from of a professional team (age 16.9 ± 1.1 years). The tests included the repeated-shuttle-sprint ability test (RSSAT), Yo-Yo Intermittent Recovery Test level 1 (Yo-Yo IR1) and Loughborough Soccer Passing Test (LSPT). Nineteen participants were randomly assigned to either the small-sided games training (SSGTG) (n = 10) or repeated-sprint training group (RSTG) (n = 9). Small-sided games or repeated-sprint training were added to the regular training sessions for two days of the regular practice week. The Wilcoxon signed-rank and Mann-Whitney U tests were used to examine differences in groups and training effects. A time x training group effect was found in the improvement of short-passing ability for the smallsided games training group which showed significantly better scores than the repeated-sprint training group (p ≤ 0.05). Both groups showed similar improvements in RSAdecrement (p < 0.05). Only the repeated-sprint training group improved in the Yo-Yo IR1 (p < 0.05). This study clearly shows that high-intensity small-sided games training can be used as an effective training mode to enhance both repeated sprint ability and short-passing ability.

  14. High-Intensity Small-Sided Games versus Repeated Sprint Training in Junior Soccer Players

    PubMed Central

    Şahan, Çağatay; Özcan, Ilker; Dinler, Kıvanç

    2017-01-01

    Abstract The aim of this study was to compare the effects of high-intensity small-sided games training (SSGT) versus repeated-sprint training (RST) on repeated-sprint ability (RSA), soccer specific endurance performance and short passing ability among junior soccer players. The junior soccer players were recruited from of a professional team (age 16.9 ± 1.1 years). The tests included the repeated-shuttle-sprint ability test (RSSAT), Yo-Yo Intermittent Recovery Test level 1 (Yo-Yo IR1) and Loughborough Soccer Passing Test (LSPT). Nineteen participants were randomly assigned to either the small-sided games training (SSGTG) (n = 10) or repeated-sprint training group (RSTG) (n = 9). Small-sided games or repeated-sprint training were added to the regular training sessions for two days of the regular practice week. The Wilcoxon signed-rank and Mann-Whitney U tests were used to examine differences in groups and training effects. A time x training group effect was found in the improvement of short-passing ability for the smallsided games training group which showed significantly better scores than the repeated-sprint training group (p ≤ 0.05). Both groups showed similar improvements in RSAdecrement (p < 0.05). Only the repeated-sprint training group improved in the Yo-Yo IR1 (p < 0.05). This study clearly shows that high-intensity small-sided games training can be used as an effective training mode to enhance both repeated sprint ability and short-passing ability. PMID:29339990

  15. Variable-Number Tandem Repeats That Are Useful in Genotyping Isolates of Salmonella enterica subsp. enterica Serovars Typhimurium and Newport▿

    PubMed Central

    Witonski, D. ; Stefanova, R.; Ranganathan, A.; Schutze, G. E.; Eisenach, K. D.; Cave, M. D.

    2006-01-01

    The genome of Salmonella enterica subsp. enterica serovar Typhimurium strain LT2 was analyzed for direct repeats, and 54 sequences containing variable-number tandem repeat loci were identified. Ten primer pairs that anneal upstream and downstream of each selected locus were designed and used to amplify PCR targets in isolates of S. enterica serovars Typhimurium and Newport. Four of the 10 loci did not show polymorphism in the length of products. Six loci were selected for analysis. Isolates of S. enterica serovars Typhimurium and Newport that were related to specific outbreaks and showed identical pulsed-field gel electrophoresis patterns were indistinguishable by the length of the six variable-number tandem repeats. Isolates that differed in their pulsed-field gel electrophoresis patterns showed polymorphism in variable-number tandem repeat profiles. Length of the products was confirmed by DNA sequence analysis. Only 2 of the 10 loci contained exact integers of the direct repeat. Eight loci contained partial copies. The partial copies were maintained at the ends of the variable-number tandem repeat loci in all isolates. In spite of having partial copies that were maintained in all isolates, the number of direct repeats at a locus was polymorphic. Six variable-number tandem repeat loci were useful in distinguishing isolates of S. enterica serovars Typhimurium and Newport that had different pulsed-field gel electrophoresis patterns and in identifying outbreak-associated cases that shared a common pulsed-field gel pattern. PMID:16943354

  16. Cardiopulmonary exercise testing early after stroke using feedback-controlled robotics-assisted treadmill exercise: test-retest reliability and repeatability.

    PubMed

    Stoller, Oliver; de Bruin, Eling D; Schindelholz, Matthias; Schuster-Amft, Corina; de Bie, Rob A; Hunt, Kenneth J

    2014-10-11

    Exercise capacity is seriously reduced after stroke. While cardiopulmonary assessment and intervention strategies have been validated for the mildly and moderately impaired populations post-stroke, there is a lack of effective concepts for stroke survivors suffering from severe motor limitations. This study investigated the test-retest reliability and repeatability of cardiopulmonary exercise testing (CPET) using feedback-controlled robotics-assisted treadmill exercise (FC-RATE) in severely motor impaired individuals early after stroke. 20 subjects (age 44-84 years, <6 month post-stroke) with severe motor limitations (Functional Ambulatory Classification 0-2) were selected for consecutive constant load testing (CLT) and incremental exercise testing (IET) within a powered exoskeleton, synchronised with a treadmill and a body weight support system. A manual human-in-the-loop feedback system was used to guide individual work rate levels. Outcome variables focussed on standard cardiopulmonary performance parameters. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean difference, limits of agreement, and coefficient of variation (CoV) were estimated to assess repeatability. Peak performance parameters during IET yielded good to excellent relative reliability: absolute peak oxygen uptake (ICC =0.82), relative peak oxygen uptake (ICC =0.72), peak work rate (ICC =0.91), peak heart rate (ICC =0.80), absolute gas exchange threshold (ICC =0.91), relative gas exchange threshold (ICC =0.88), oxygen cost of work (ICC =0.87), oxygen pulse at peak oxygen uptake (ICC =0.92), ventilation rate versus carbon dioxide output slope (ICC =0.78). For these variables, SEM was 4-13%, MDC 12-36%, and CoV 0.10-0.36. CLT revealed high mean differences and insufficient test-retest reliability for all variables studied. This study presents first evidence on reliability and repeatability for CPET in severely motor impaired individuals early after stroke using a feedback-controlled robotics-assisted treadmill. The results demonstrate good to excellent test-retest reliability and appropriate repeatability for the most important peak cardiopulmonary performance parameters. These findings have important implications for the design and implementation of cardiovascular exercise interventions in severely impaired populations. Future research needs to develop advanced control strategies to enable the true limit of functional exercise capacity to be reached and to further assess test-retest reliability and repeatability in larger samples.

  17. A two-question tool to assess the risk of repeated falls in the elderly

    PubMed Central

    Gálvez-Barrón, César; Narvaiza, Leire; Miñarro, Antonio; Ruiz, Jorge; Valldosera, Esther; Gonzalo, Natalia; Ng, Thalia; Sanguino, María Jesús; Yuste, Antonio

    2017-01-01

    Introduction Older adults’ perception of their own risk of fall has never been included into screening tools. The goal of this study was to evaluate the predictive validity of questions on subjects’ self-perception of their own risk of fall. Methods This prospective study was conducted on a probabilistic sample of 772 Spanish community-dwelling older adults, who were followed-up for a one year period. At a baseline visit, subjects were asked about their recent history of falls (question 1: “Have you fallen in the last 6 months?”), as well as on their perception of their own risk of fall by using two questions (question 2: “Do you think you may fall in the next few months?” possible answers: yes/no; question 3: “What is the probability that you fall in the next few months?” possible answers: low/intermediate/high). The follow-up consisted of quarterly telephone calls, where the number of falls occurred in that period was recorded. Results A short questionnaire built with questions 1 and 3 showed 70% sensitivity (95% CI: 56%-84%), 72% specificity (95% CI: 68%-76%) and 0.74 area under the ROC curve (95% CI: 0.66–0.82) for prediction of repeated falls in the subsequent year. Conclusions The estimation of one’s own risk of fall has predictive validity for the occurrence of repeated falls in older adults. A short questionnaire including a question on perception of one’s own risk of fall and a question on the recent history of falls had good predictive validity. PMID:28489888

  18. Evaluation of FUS-2000 urine analyzer: analytical properties and particle recognition.

    PubMed

    Beňovská, Miroslava; Wiewiorka, Ondřej; Pinkavová, Jana

    This study evaluates the performance of microscopic part of a hybrid analyzer FUS-2000 (Dirui Industrial Co., Changchun, China), its analytical properties and particle recognition. The evaluation of trueness, repeatability, detection limit, carry-over, linearity range and analytical stability was performed according to Dirui protocol guidelines designed by Dirui Company to guarantee the quality of the instrument. Trueness for low, medium and high-value concentrations was calculated with bias of 15.5, 4.7 and -6.6%, respectively. Detection limit of 5 Ery/μl was confirmed. Coefficient of variation of 11.0, 5.2 and 3.8% was measured for within-run repeatability of low, medium and high concentration. Between-run repeatability for daily quality control had coefficient of variation of 3.0%. Carry-over did not exceed 0.05%. Linearity was confirmed for range of 0-16,000 particles/μl (R 2  = 0.9997). The analytical stability had coefficient of variation of 4.3%. Out of 1258 analyzed urine samples, 362 positive were subjected to light microscopy urine sediment analysis and compared to the analyzer results. Cohen's kappa coefficients were calculated to express the concordance. Squared kappa coefficient was 0.927 (red blood cells), 0.888 (white blood cells), 0.908 (squamous epithelia), 0.634 (transitional epithelia), 0.628 (hyaline casts), 0.843 (granular casts) and 0.623 (bacteria). Single kappa coefficients were 0.885 (yeasts) and 0.756 (crystals), respectively. Aforementioned results show good analytical performance of the analyzer and tight agreement with light microscopy of urine sediment.

  19. Production of novel recombinant single-domain antibodies against tandem repeat region of MUC1 mucin.

    PubMed

    Rahbarizadeh, F; Rasaee, M J; Forouzandeh Moghadam, M; Allameh, A A; Sadroddiny, E

    2004-06-01

    Recently, the existence of "heavy-chain" antibody in Camelidae has been described. However, as yet there is no data on the binding of this type of antibody to peptides. In addition, there was not any report of production of single-domain antibodies in two-humped camels (Camelus bactrianus). In the present study, these questions are addressed. We showed the feasibility of immunizing old world camels, cloning the repertoire of the variable domain of their heavy-chain antibodies, panning and selection, leading to the successful identification of minimum-sized antigen binders. Antigen-specific fragments of the heavy-chain IgGs (V(HH)) are of great interest in biotechnology because they are very stable, highly soluble, and react specifically and with high affinity to the antigens. In this study, we immunized two camels (Camelus dromedarius and Camelus bactrianus) with homogenized cancerous tissues, synthetic peptide, and human milk fat globule membrane (HMFG), and generated two V(HH) libraries displayed on phage particles. Some single-domain antibody fragments have been isolated that specifically recognize the tandem repeat region of MUC1. The camels' single-domain V(HH) harbor the original, intact antigen binding site and reacted specifically and with high affinity to the tandem repeat region of MUC1. Indeed soluble, specific antigen binders and good affinities (in the range of 0.2 x 10(9) M(-1) to 0.6 x 10(9) M(-1)) were identified from these libraries. This is the first example of the isolation of camel anti-peptide V(HH) domains.

  20. Effect of fractionation on treatment outcome in local dual-frequency sonication and Dox-encapsulated nanomicelles.

    PubMed

    Hasanzadeh, Hadi; Mokhtari-Dizaji, Manijhe; Bathaie, S Zahra; Hassan, Zuhair M

    2013-10-01

    The goal of this study was to localize drug release from nanomicelles using dual-frequency sonication at low levels of acoustic intensity. In this study, the antitumor effect of simultaneous dual-frequency sonication (28 kHz and 3 MHz) at low levels of acoustic intensity in combination with doxorubicin and micellar doxorubicin injection was assessed in a spontaneous model of breast adenocarcinoma in female Balb/c mice. Sixty-three tumor-bearing mice were randomly grouped into control, sham, dual-frequency sonication, doxorubicin injection with and without dual-frequency sonication, and micellar doxorubicin injection with and without dual-frequency sonication groups. The results of volume change relative to initial volume showed that in the micellar doxorubicin injection with sonication group, this parameter was significantly different from that of the control, sham, sonication, and doxorubicin injection groups (P < 0.05). In addition, the volume began to increase on the 15th day after the start of treatment, which is a good indication to repeat treatment; therefore, another group received an extra treatment on day 15. The animal life span in the micellar doxorubicin with sonication and repeated treatment groups was significantly higher than that in all the other experimental groups except for the micellar doxorubicin injection group (P < 0.05). It was concluded that dual-frequency sonication with micellar doxorubicin injection extends the life span relative to doxorubicin injection or dual-frequency sonication alone, and that repeating this treatment on day 15 decreases the rate of tumor growth significantly.

  1. Science Students and the Social Sciences: Strange Bedfellows?

    ERIC Educational Resources Information Center

    Yeong, Foong May

    2014-01-01

    With various internet resources available to students, the main aim of a good university education today should not merely be to provide students with content knowledge, but rather to equip them with essential skills necessary to develop into lifelong learners. Among science educators, repeated calls have been made to promote a more holistic…

  2. Essential Questions

    ERIC Educational Resources Information Center

    Wilhelm, Jeffrey D.

    2012-01-01

    The secret to teaching may be as simple as asking students good questions--and then giving them the opportunity to find the answers. The author shares how he uses essential questions that set the class off on an inquiry. Rather than consuming information that he distributes and then repeating it on a test, students carry out their own…

  3. Ireland's Generic Repeat Design Schools Programme

    ERIC Educational Resources Information Center

    Sheppard, Tony

    2011-01-01

    The Irish Department of Education and Skills (DoE) is strongly committed to energy efficiency and to reducing CO[subscript 2] by developing and implementing energy level ceilings in relation to school design that aim to remain below half of the accepted good practice in the field. This approach works within normal departmental budgetary limits to…

  4. Nurses are leading the way in changing attitudes to dementia.

    PubMed

    Bates, Jane

    2016-08-10

    My father and I had a pact - we would never repeat the daft things my grandmother said. We just couldn't bear people laughing at her. My granny had always been warm, witty and wise. Now in her eighties, she was in good form physically, but her memory had left the building.

  5. Efforts to update firefighter safety zone guidelines

    Treesearch

    Bret Butler

    2009-01-01

    One of the most critical decisions made on wildland fires is the identification of suitable safety zones for firefighters during daily fire management operations. To be effective (timely, repeatable, and accurate), these decisions rely on good training and judgment, but also on clear, concise guidelines. This article is a summary of safety zone guidelines and the...

  6. Doing Right Things Right

    ERIC Educational Resources Information Center

    Perna, Mark C.

    2006-01-01

    Attracting quality students in sufficient volume requires schools to do the right things right. Doing right things right is a combination of what they do and how well they do it. Successful enrollment marketing, like all good marketing, depends on consistency of effort and doing enough of the right things in the right way, repeatedly. Here, the…

  7. A Comparative Proteomic Analysis of the Simple Amino Acid Repeat Distributions in Plasmodia Reveals Lineage Specific Amino Acid Selection

    PubMed Central

    Dalby, Andrew R.

    2009-01-01

    Background Microsatellites have been used extensively in the field of comparative genomics. By studying microsatellites in coding regions we have a simple model of how genotypic changes undergo selection as they are directly expressed in the phenotype as altered proteins. The simplest of these tandem repeats in coding regions are the tri-nucleotide repeats which produce a repeat of a single amino acid when translated into proteins. Tri-nucleotide repeats are often disease associated, and are also known to be unstable to both expansion and contraction. This makes them sensitive markers for studying proteome evolution, in closely related species. Results The evolutionary history of the family of malarial causing parasites Plasmodia is complex because of the life-cycle of the organism, where it interacts with a number of different hosts and goes through a series of tissue specific stages. This study shows that the divergence between the primate and rodent malarial parasites has resulted in a lineage specific change in the simple amino acid repeat distribution that is correlated to A–T content. The paper also shows that this altered use of amino acids in SAARs is consistent with the repeat distributions being under selective pressure. Conclusions The study shows that simple amino acid repeat distributions can be used to group related species and to examine their phylogenetic relationships. This study also shows that an outgroup species with a similar A–T content can be distinguished based only on the amino acid usage in repeats, and suggest that this might be a useful feature for proteome clustering. The lineage specific use of amino acids in repeat regions suggests that comparative studies of SAAR distributions between proteomes gives an insight into the mechanisms of expansion and the selective pressures acting on the organism. PMID:19597555

  8. Testing the Prediction of Iron Alteration Minerals on Low Albedo Asteroids

    NASA Technical Reports Server (NTRS)

    Jarvis, K. S.; Vilas, Faith; Howell, E.; Kelley, M.; Cochran, A.

    1999-01-01

    Absorption features centered near 0.60 - 0.65 and 0.80 - 0.90 micron were identified in the spectra of three low-albedo main-belt (165, 368, 877) and two low-albedo outer-belt (225, 334) asteroids (Vilas et al., Icarus, v. 109,274,1994). The absorption features were attributed to charge transfer transitions in iron alteration minerals such as goethite, hematite, and jarosite, all products of aqueous alteration. Concurrently, Jarvis et al. (LPSC XXIV, 715, 1993) presented additional spectra of low-albedo asteroids that had absorption features centered near 0.60 - 0.65 micron without the longer wavelength feature. Since these two features in iron oxides originate from the same ground state, and the longer wavelength feature requires less energy to exist, the single shorter wavelength feature cannot be caused by the iron alteration minerals. In addition, spectra of minerals such as hematite and goethite show a rapid increase in reflectance beginning near 0.5 micron absent in the low-albedo asteroid spectra. The absence of this rise has been attributed to its suppresion from opaques in the surface material. Spectra on more than one night were available for only one of these five asteroids, 225 Henrietta, and showed good repeatability of the 0.65-micron feature. We have acquired additional spectra of all five asteroids in order to test the repeatability of the 0.65-micron feature, and the presence and repeatability of the features centered near 0.8 - 0.9 micron. We specifically will test the possibility that longer wavelength features could be caused by incomplete removal of telluric water. Asteroid 877 Walkure is a member of the Nysa-Hertha family, and will be compared to spectra of other members of that family. Data were acquired in 1996 and 1999 on the 2.1-m telescope with a facility cassegrain spectrograph, McDonald Observatory, Univ. Of Texas, and the 1.5-m telescope with facility cassegrain spectrograph at CTIO. This research is supported by the NASA Planetary Astronomy Program.

  9. Isolation and characterisation of the biological repeating unit of cepacian, the exopolysaccharide produced by bacteria of the Burkholderia cepacia complex.

    PubMed

    Cescutti, Paola; Foschiatti, Michela; Furlanis, Linda; Lagatolla, Cristina; Rizzo, Roberto

    2010-07-02

    The repeating unit of cepacian, the exopolysaccharide produced by the majority of the microorganisms belonging to the Burkholderia cepacia complex, was isolated from inner bacterial membranes and investigated by mass spectrometry, with and without prior derivatisation. Interpretation of the mass spectra led to the determination of the biological repeating unit primary structure, thus disclosing the nature of the oligosaccharide produced in vivo. Moreover, mass spectra recorded on the native sample revealed that acetyl substitution was very variable, producing a mixture of repeating units containing zero to four acyl groups. At the same time, finding acetylated oligosaccharides showed that binding of these substituents occurred in the cellular periplasmic space, before the polymerisation process took place. In the chromatographic peak containing the repeating unit, oligosaccharides shorter than the repeating unit co-eluted. Mass spectrometric analysis showed that they were biosynthetic intermediates of the repeating unit and further investigation revealed the biosynthetic sequence of cepacian building block. Copyright 2010 Elsevier Ltd. All rights reserved.

  10. DNA-binding proteins from marine bacteria expand the known sequence diversity of TALE-like repeats.

    PubMed

    de Lange, Orlando; Wolf, Christina; Thiel, Philipp; Krüger, Jens; Kleusch, Christian; Kohlbacher, Oliver; Lahaye, Thomas

    2015-11-16

    Transcription Activator-Like Effectors (TALEs) of Xanthomonas bacteria are programmable DNA binding proteins with unprecedented target specificity. Comparative studies into TALE repeat structure and function are hindered by the limited sequence variation among TALE repeats. More sequence-diverse TALE-like proteins are known from Ralstonia solanacearum (RipTALs) and Burkholderia rhizoxinica (Bats), but RipTAL and Bat repeats are conserved with those of TALEs around the DNA-binding residue. We study two novel marine-organism TALE-like proteins (MOrTL1 and MOrTL2), the first to date of non-terrestrial origin. We have assessed their DNA-binding properties and modelled repeat structures. We found that repeats from these proteins mediate sequence specific DNA binding conforming to the TALE code, despite low sequence similarity to TALE repeats, and with novel residues around the BSR. However, MOrTL1 repeats show greater sequence discriminating power than MOrTL2 repeats. Sequence alignments show that there are only three residues conserved between repeats of all TALE-like proteins including the two new additions. This conserved motif could prove useful as an identifier for future TALE-likes. Additionally, comparing MOrTL repeats with those of other TALE-likes suggests a common evolutionary origin for the TALEs, RipTALs and Bats. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  11. Determination of free formaldehyde in cosmetics containing formaldehyde-releasing preservatives by reversed-phase dispersive liquid-liquid microextraction and liquid chromatography with post-column derivatization.

    PubMed

    Miralles, Pablo; Chisvert, Alberto; Alonso, M José; Hernandorena, Sandra; Salvador, Amparo

    2018-03-30

    An analytical method for the determination of traces of formaldehyde in cosmetic products containing formaldehyde-releasing preservatives has been developed. The method is based on reversed-phase dispersive liquid-liquid microextraction (RP-DLLME), that allows the extraction of highly polar compounds, followed by liquid chromatography-ultraviolet/visible (LC-UV/vis) determination with post-column derivatization. The variables involved in the RP-DLLME process were studied to provide the best enrichment factors. Under the selected conditions, a mixture of 500 μL of acetonitrile (disperser solvent) and 50 μL of water (extraction solvent) was rapidly injected into 5 mL of toluene sample solution. The extracts were injected into the LC-UV/vis system using phosphate buffer 6 mmol L -1 at pH 2 as mobile phase. After chromatographic separation, the eluate merged with a flow stream of pentane-2,4-dione in ammonium acetate solution as derivatizing reagent and passed throughout a post-column reactor at 85 °C in order to derivatize formaldehyde into 3,5-diacetyl-1,4-dihydrolutidine, according to Hantzsch reaction, which was finally measured spectrophotometrically at 407 nm. The method was successfully validated showing good linearity, an enrichment factor of 86 ± 2, limits of detection and quantification of 0.7 and 2.3 ng mL -1 , respectively, and good repeatability (RSD < 9.2%). Finally, the proposed analytical method was applied to the determination of formaldehyde in different commercial cosmetic samples containing formaldehyde-releasing preservatives, such as bronopol, diazolidinyl urea, imidazolidinyl urea, and DMDM hydantoin, with good relative recovery values (91-113%) thus showing that matrix effects were negligible. The good analytical features of the proposed method besides of its simplicity and affordability, make it useful to carry out the quality control of cosmetic products containing formaldehyde-releasing preservatives. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. MSH3 polymorphisms and protein levels affect CAG repeat instability in Huntington's disease mice.

    PubMed

    Tomé, Stéphanie; Manley, Kevin; Simard, Jodie P; Clark, Greg W; Slean, Meghan M; Swami, Meera; Shelbourne, Peggy F; Tillier, Elisabeth R M; Monckton, Darren G; Messer, Anne; Pearson, Christopher E

    2013-01-01

    Expansions of trinucleotide CAG/CTG repeats in somatic tissues are thought to contribute to ongoing disease progression through an affected individual's life with Huntington's disease or myotonic dystrophy. Broad ranges of repeat instability arise between individuals with expanded repeats, suggesting the existence of modifiers of repeat instability. Mice with expanded CAG/CTG repeats show variable levels of instability depending upon mouse strain. However, to date the genetic modifiers underlying these differences have not been identified. We show that in liver and striatum the R6/1 Huntington's disease (HD) (CAG)∼100 transgene, when present in a congenic C57BL/6J (B6) background, incurred expansion-biased repeat mutations, whereas the repeat was stable in a congenic BALB/cByJ (CBy) background. Reciprocal congenic mice revealed the Msh3 gene as the determinant for the differences in repeat instability. Expansion bias was observed in congenic mice homozygous for the B6 Msh3 gene on a CBy background, while the CAG tract was stabilized in congenics homozygous for the CBy Msh3 gene on a B6 background. The CAG stabilization was as dramatic as genetic deficiency of Msh2. The B6 and CBy Msh3 genes had identical promoters but differed in coding regions and showed strikingly different protein levels. B6 MSH3 variant protein is highly expressed and associated with CAG expansions, while the CBy MSH3 variant protein is expressed at barely detectable levels, associating with CAG stability. The DHFR protein, which is divergently transcribed from a promoter shared by the Msh3 gene, did not show varied levels between mouse strains. Thus, naturally occurring MSH3 protein polymorphisms are modifiers of CAG repeat instability, likely through variable MSH3 protein stability. Since evidence supports that somatic CAG instability is a modifier and predictor of disease, our data are consistent with the hypothesis that variable levels of CAG instability associated with polymorphisms of DNA repair genes may have prognostic implications for various repeat-associated diseases.

  13. MSH3 Polymorphisms and Protein Levels Affect CAG Repeat Instability in Huntington's Disease Mice

    PubMed Central

    Simard, Jodie P.; Clark, Greg W.; Slean, Meghan M.; Swami, Meera; Shelbourne, Peggy F.; Tillier, Elisabeth R. M.; Monckton, Darren G.; Messer, Anne; Pearson, Christopher E.

    2013-01-01

    Expansions of trinucleotide CAG/CTG repeats in somatic tissues are thought to contribute to ongoing disease progression through an affected individual's life with Huntington's disease or myotonic dystrophy. Broad ranges of repeat instability arise between individuals with expanded repeats, suggesting the existence of modifiers of repeat instability. Mice with expanded CAG/CTG repeats show variable levels of instability depending upon mouse strain. However, to date the genetic modifiers underlying these differences have not been identified. We show that in liver and striatum the R6/1 Huntington's disease (HD) (CAG)∼100 transgene, when present in a congenic C57BL/6J (B6) background, incurred expansion-biased repeat mutations, whereas the repeat was stable in a congenic BALB/cByJ (CBy) background. Reciprocal congenic mice revealed the Msh3 gene as the determinant for the differences in repeat instability. Expansion bias was observed in congenic mice homozygous for the B6 Msh3 gene on a CBy background, while the CAG tract was stabilized in congenics homozygous for the CBy Msh3 gene on a B6 background. The CAG stabilization was as dramatic as genetic deficiency of Msh2. The B6 and CBy Msh3 genes had identical promoters but differed in coding regions and showed strikingly different protein levels. B6 MSH3 variant protein is highly expressed and associated with CAG expansions, while the CBy MSH3 variant protein is expressed at barely detectable levels, associating with CAG stability. The DHFR protein, which is divergently transcribed from a promoter shared by the Msh3 gene, did not show varied levels between mouse strains. Thus, naturally occurring MSH3 protein polymorphisms are modifiers of CAG repeat instability, likely through variable MSH3 protein stability. Since evidence supports that somatic CAG instability is a modifier and predictor of disease, our data are consistent with the hypothesis that variable levels of CAG instability associated with polymorphisms of DNA repair genes may have prognostic implications for various repeat-associated diseases. PMID:23468640

  14. A glucose biosensor based on glucose oxidase immobilized on three-dimensional porous carbon electrodes.

    PubMed

    Chen, Jingyi; Zhu, Rong; Huang, Jia; Zhang, Man; Liu, Hongyu; Sun, Min; Wang, Li; Song, Yonghai

    2015-08-21

    A novel glucose biosensor was developed by immobilizing glucose oxidase (GOD) on a three-dimensional (3D) porous kenaf stem-derived carbon (3D-KSC) which was firstly proposed as a novel supporting material to load biomolecules for electrochemical biosensing. Here, an integrated 3D-KSC electrode was prepared by using a whole piece of 3D-KSC to load the GOD molecules for glucose biosensing. The morphologies of integrated 3D-KSC and 3D-KSC/GOD electrodes were characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The SEM results revealed a 3D honeycomb macroporous structure of the integrated 3D-KSC electrode. The TEM results showed some microporosities and defects in the 3D-KSC electrode. The electrochemical behaviors and electrocatalytic performance of the integrated 3D-KSC/GOD electrode were evaluated by cyclic voltammetry and electrochemical impedance spectroscopy. The effects of pH and scan rates on the electrochemical response of the biosensor have been studied in detail. The glucose biosensor showed a wide linear range from 0.1 mM to 14.0 mM with a high sensitivity of 1.73 μA mM(-1) and a low detection limit of 50.75 μM. Furthermore, the glucose biosensor exhibited high selectivity, good repeatability and reproducibility, and good stability.

  15. Simultaneous determination of 76 micropollutants in water samples by headspace solid phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Martínez, C; Ramírez, N; Gómez, V; Pocurull, E; Borrull, F

    2013-11-15

    This study focuses on the development of an analytical method based on headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of 76 micropollutants in water samples. The selected micropollutants include volatile organic compounds (VOCs) (e.g. chlorobenzenes, chloroalkanes), endocrine disrupting compounds (EDCs) (e.g. bisphenol A and tributyl phosphate), odour compounds (e.g. limonene, phenol), fragrance allergens (e.g. geraniol, eugenol) and some pesticides (e.g. heptachlor, terbutryn). The experimental conditions affecting their extraction, such as the type of fibre, temperature and time of extraction, sample volume and ionic strength of the samples were optimized using HS-SPME. The method showed good linear range, reproducibility between days, repeatability and low detection limits (at ng L(-1) levels). The validated method has been applied to determine the target organic micropollutants in aqueous samples from different experimental research units of surface water, sea water, waste water and those effluents of advance membrane treatments. The optimized method showed good performance in the different types of samples studied. The analysis revealed the presence of several micropollutants at concentrations between 20 and 5000 μg L(-1), such as ethylbenzene, o-xylene, p-isopropilbenzene, D-limonene, citral and isoeugenol, due to the fact that these species are commonly used in domestic and industrial applications. © 2013 Elsevier B.V. All rights reserved.

  16. Innovative analytical method for the determination of underivatized tributyltin and pentachlorophenol in seawater by gas chromatography-triple quadrupole mass spectrometry.

    PubMed

    Amendola, Luca; Cortese, Maria; Vinatoru, Daniela; Sposato, Silvana; Insogna, Susanna

    2017-07-04

    Tributyltin (TBT) and pentachlorophenol (PCP) are listed as priority substances that warrant monitoring in the European Water Framework Directive (WFD 2000/60/CE), since TBT and PCP were identified as environmental endocrine disruptors and exhibit considerable toxicity toward both aquatic organisms and mammals even at very low levels. This paper shows a novel approach to analyze underivatized tributyltin (TBT) and pentachlorophenol (PCP) in seawater based on capillary gas chromatography-triple quadrupole mass spectrometry. The optimized extraction method for TBT an PCP in water involved liquid-liquid microextraction with toluene. The reduced extract was added with a solvent mix, composed of methanol and trimethylsilyl derivatives of methanol (MeOTMS), that allowed good chromatographic resolution of underivatized TBT and PCP, interacting as a lubricant along the glass liner during the injection phase. The proposed method showed good linearity and repeatability (RSD%<20% at 0.05 ng L -1 for TBT and 0.2 μg L -1 for PCP). The overall recoveries were 74% and 106% for TBT and PCP, respectively. Very low quantification limits that met the strict statutory and regulatory demands were achieved: 0.002 ng L -1 for TBT and 0.050 μg L -1 for PCP. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. An Enzyme-Induced Novel Biosensor for the Sensitive Electrochemical Determination of Isoniazid

    PubMed Central

    Chokkareddy, Rajasekhar; Bhajanthri, Natesh Kumar; Redhi, Gan G.

    2017-01-01

    In this present work, a glassy carbon electrode (GCE) was modified primarily with multiwalled carbon nanotubes (MWCNTs) and a composite of MWCNTs and titanium oxide nanoparticles (TiO2NPs). The enzyme horseradish peroxidase (HRP) was immobilized to enhance the sensing ability of GCE. The proposed biosensor was used for the sensitive determination of isoniazid (INZ) in various pharmaceutical samples. The electrochemical behaviour of the developed MWCNT-TiO2NPs-HRP-GCE biosensor was studied by using cyclic voltammetry (CV) and differential pulse voltammetric (DPV) techniques. Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), thermogravimetry (TGA) and transmission electron microscopy (TEM) techniques were used to characterize the developed sensor. Phosphate buffer solution (PBS) with pH 7 was used as supporting electrolyte in the present investigation. The cyclic voltammetric results revealed that the increment of anodic peak currents for the enzyme-induced sensor was almost 8-fold greater than that of a bare GCE. The DPV technique exhibited good limit of detection and limit of quantification values, viz., 0.0335 μM and 0.1118 μM, respectively. Moreover, the developed sensor showed long-lasting stability and repeatability without any interferents. This strongly indicates that the fabricated sensor shows outstanding electrochemical performance towards INZ, with excellent selectivity and sensitivity. The developed sensor was successfully applied to pharmaceutical samples and gave good percentages of recoveries. PMID:28587260

  18. Enantioselective piezoelectric quartz crystal sensor for d-methamphetamine based on a molecularly imprinted polymer.

    PubMed

    Arenas, Leveriza F; Ebarvia, Benilda S; Sevilla, Fortunato B

    2010-08-01

    A piezoelectric quartz crystal (PQC) sensor based on a molecularly imprinted polymer (MIP) has been developed for enantioselective and quantitative analysis of d-(+)-methamphetamine (d(+)-MA). The sensor was produced by bulk polymerization and the resulting MIP was then coated on the gold electrode of an AT-cut quartz crystal. Conditions such as volume of polymer coating, curing time, type of PQC, baseline solvent, pH, and buffer type were found to affect the sensor response and were therefore optimized. The PQC-MIP gave a stable response to different concentrations of d(+)-MA standard solutions (response time = 10 to 100 s) with good repeatability (RSD = 0.03 to 3.09%; n = 3), good reproducibility (RSD = 3.55%; n = 5), and good reversibility (RSD = 0.36%; n = 3). The linear range of the sensor covered five orders of magnitude of analyte concentration, ranging from 10(-5) to 10(-1) microg mL(-1), and the limit of detection was calculated as 11.9 pg d(+)-MA mL(-1) . The sensor had a highly enantioselective response to d(+)-MA compared with its response to l(-)-MA, racemic MA, and phentermine. The developed sensor was validated by applying it to human urine samples from drug-free individuals spiked with standard d(+)-MA and from a confirmed MA user. Use of the standard addition method (SAM) and samples spiked with d(+)-MA at levels ranging from 1 x 10(-3) to 1 x 10(-2) microg mL(-1) showed recovery was good (95.3 to 110.9%).

  19. Fast Gaussian kernel learning for classification tasks based on specially structured global optimization.

    PubMed

    Zhong, Shangping; Chen, Tianshun; He, Fengying; Niu, Yuzhen

    2014-09-01

    For a practical pattern classification task solved by kernel methods, the computing time is mainly spent on kernel learning (or training). However, the current kernel learning approaches are based on local optimization techniques, and hard to have good time performances, especially for large datasets. Thus the existing algorithms cannot be easily extended to large-scale tasks. In this paper, we present a fast Gaussian kernel learning method by solving a specially structured global optimization (SSGO) problem. We optimize the Gaussian kernel function by using the formulated kernel target alignment criterion, which is a difference of increasing (d.i.) functions. Through using a power-transformation based convexification method, the objective criterion can be represented as a difference of convex (d.c.) functions with a fixed power-transformation parameter. And the objective programming problem can then be converted to a SSGO problem: globally minimizing a concave function over a convex set. The SSGO problem is classical and has good solvability. Thus, to find the global optimal solution efficiently, we can adopt the improved Hoffman's outer approximation method, which need not repeat the searching procedure with different starting points to locate the best local minimum. Also, the proposed method can be proven to converge to the global solution for any classification task. We evaluate the proposed method on twenty benchmark datasets, and compare it with four other Gaussian kernel learning methods. Experimental results show that the proposed method stably achieves both good time-efficiency performance and good classification performance. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Photoresponse and learning behavior of ascidian larvae, a primitive chordate, to repeated stimuli of step-up and step-down of light.

    PubMed

    Kawakami, I; Shiraishi, S; Tsuda, M

    2002-09-01

    Ascidians are lower chordates and their simple tadpole-like larvae share a basic body plan with vertebrates. Newly hatched larvae show no response to a stimulus of light. 4 h after hatching, the larvae were induced to swim upon a step-down of light and stop swimming upon a step-up of light. At weaker intensity of light, the larvae show the same response to a stimulus after presentation of repeated stimuli. When intensity of actinic light was increased, the larvae show sensitization and habituation of the swimming response to a stimulus after repeated stimuli of step-down and step-up of the light. Between 2 h 20 min and 3 h 40 min after hatching the larvae did not show any response to the first stimulus, but after several repeatedstimuli they show swimming response to a step-down of light. A repeated series of stimulus cause sensitization. Between 4 h and 7 h after hatching, the larvae show photoresponse to the first stimulus, but after several repetition of the stimuli, the larvae could not stop swimming to a stimulus of a step-up of the actinic light. A repeated series of stimulus cause greaterhabituation. Both sensitization and habituation depend upon intensity ofactinic light.

  1. All-photonic quantum repeaters

    PubMed Central

    Azuma, Koji; Tamaki, Kiyoshi; Lo, Hoi-Kwong

    2015-01-01

    Quantum communication holds promise for unconditionally secure transmission of secret messages and faithful transfer of unknown quantum states. Photons appear to be the medium of choice for quantum communication. Owing to photon losses, robust quantum communication over long lossy channels requires quantum repeaters. It is widely believed that a necessary and highly demanding requirement for quantum repeaters is the existence of matter quantum memories. Here we show that such a requirement is, in fact, unnecessary by introducing the concept of all-photonic quantum repeaters based on flying qubits. In particular, we present a protocol based on photonic cluster-state machine guns and a loss-tolerant measurement equipped with local high-speed active feedforwards. We show that, with such all-photonic quantum repeaters, the communication efficiency scales polynomially with the channel distance. Our result paves a new route towards quantum repeaters with efficient single-photon sources rather than matter quantum memories. PMID:25873153

  2. Reconditioning perovskite films in vapor environments through repeated cation doping

    NASA Astrophysics Data System (ADS)

    Boonthum, Chirapa; Pinsuwan, Kusuma; Ponchai, Jitprabhat; Srikhirin, Toemsak; Kanjanaboos, Pongsakorn

    2018-06-01

    Perovskites have attracted considerable attention for application as high-efficiency photovoltaic devices owing to their low-cost and low-temperature fabrication. A good surface and high crystallinity are necessary for high-performance devices. We examine the negative effects of chemical ambiences on the perovskite crystal formation and morphology. The repeated cation doping (RCD) technique was developed to remedy these issues by gradually dropping methylammonium ions on top of about-to-form perovskite surfaces to cause recrystallization. RCD promotes pinhole-free, compact, and polygonal-like surfaces under various vapor conditions. Furthermore, it enhances the electronic properties and crystallization. The benefits of RCD extend beyond perovskites under vapor ambiences, as it can improve regular and wasted perovskites.

  3. Test-retest reliability of laser displacement mechanomyography in paraspinal muscles while in lumbar extension or flexion.

    PubMed

    Than, Christian; Seidl, Laura; Tosovic, Danijel; Brown, J Mark

    2018-05-12

    This study investigated test-retest reliability of mechanomyography (MMG) on lumbar paraspinal muscles. Healthy male and female subjects (mean ± standard deviation, 25 ± 9.4 years, BMI 21.8 ± 2.99, n = 34) were recruited. Two test sessions (one week apart) consisted of MMG (laser displacement sensor (LDS)) muscle evaluations over the 10 lumbar facet joints, and 2 bilateral sacral sites, in anatomical extension and flexion. Two-way repeated measures ANOVA with Tukey's post hoc showed no significant differences between testing sessions for the same position (p > 0.05). The intra-class correlation coefficients (ICCs) in extension were classified as 'very good' (0.8-0.9) for maximal muscle displacement (Dmax), contraction time (Tc) and velocity of contraction (Vr). Half relaxation time (½Tr) and half relaxation velocity (½Vr) were 'poor' (0.4-0.5) and 'good' (0.7-0.8). In flexion, Dmax, Tc and Vr were 'excellent' (≥0.9) whilst ½Tr and ½Vr were 'fair' (0.6-0.7) and 'very good'. Comparing extension against flexion, significant (p < 0.05) differences in Dmax and ½Vr were found (L1/L2-L5/S1). Tc was significant (p < 0.05) for all sites whilst Vc was for L1/L2 on both sides (p < 0.05). ½Tr showed no significance (p > 0.05). Most MMG-derived parameters thus appear as reliable measures of muscle contractile properties in lumbar extension and flexion, with flexion providing more reliable results (ICCs). Copyright © 2018. Published by Elsevier Ltd.

  4. TU-F-CAMPUS-I-01: Head and Neck Squamous Cell Carcinoma: Short-Term Repeatability of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion Parameters at 3.0T

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Y; Fuller, C; Mohamed, A

    2015-06-15

    Purpose: Many published studies have recently demonstrated the potential value of intravoxel incoherent motion (IVIM) analysis for disease evaluation. However, few have questioned its measurement repeatability/reproducibility when applied. The purpose of this study was to determine the short-term measurement repeatability of apparent diffusion coefficient ADC, true diffusion coefficient D, pseudodiffusion coefficient D* and perfusion fraction f, in head and neck squamous cell carcinoma (HNSCC) primary tumors and metastatic nodes. Methods: Ten patients with known HNSCC were examined twice using echo-planar DW-MRI with 12 b values (0 to 800 s/mm2) 1hour to 24 hours apart before radiation treatment. All patients weremore » scanned with the customized radiation treatment immobilization devices to reduce motion artifacts and to improve image registration in repeat scans. Regions of interests were drawn in primary tumor and metastases node in each patient (Fig. 1). ADC and IVIM parameters D, D* and f were calculated by least squares data fitting. Short-term test–retest repeatability of ADC and IVIM parameters were assessed by measuring Bland–Altman limits of agreements (BA-LA). Results: Sixteen HNSCC lesions were assessed in 10 patients. Repeatability of perfusion-sensitive parameters, D* and f, in HNSCC lesions was poor (BA-LA: -144% to 88% and −57% to 96% for D* and f, respectively); a lesser extent was observed for the diffusion-sensitive parameters of ADC and D (BA-LA: −34% to 39% and −37% to 40%, for ADC and D, respectively) (Fig. 2). Conclusion: Poor repeatability of D*/f and good repeatability for ADC/D were observed in HNSCC primary tumors and metastatic nodes. Efforts should be made to improve the measurement repeatability of perfusion-sensitive IVIM parameters.« less

  5. Giant fibrovascular esophageal polyp misdiagnosed as achalasia.

    PubMed

    Cordoş, I; Istrate, A; Codreşi, M; Bolca, C

    2012-01-01

    A 59 years old woman was admitted in our unit accusing longtime dysphagia and regurgitation. On admission, the patient was wearing a 3 month old definitive feeding gastrostomy tube. The contrast swallow, endoscopy and esophageal manometry established the diagnostic--achalasia. We removed the gastrostomy tube and we performed an open Heller myotomy. The postoperative period was uneventful and the patient was discharged one week later with affirmatively unimpaired deglutition. One month later, the patient was admitted via emergency with a giant fibrous tumor arising from her mouth after an episode of strong coughing and vomiting. The repeated endoscopy showed a giant esophageal polyp that was missed by the previous investigations, originating from pharingoesophageal junction. The esophageal polyp was resected by cervical approach with good postoperative outcome. The polyp's particular extreme dimensions (27 cm) prevented the acute asphyxia by blockage at the laryngeal level, possibly provoked by smaller tumors. As postoperative one month barium swallow showed a normal esophageal aspect, a final question remains--was achalasia real or an erroneous diagnosis was established the second time too?

  6. Development of QCM Trimethylamine Sensor Based on Water Soluble Polyaniline.

    PubMed

    Li, Guang; Zheng, Junbao; Ma, Xingfa; Sun, Yu; Fu, Jun; Wu, Gang

    2007-10-17

    A rapid, sensitive, low-cost device to detect trimethylamine was presented in thispaper. The preparation of water soluble polyaniline was firstly studied. Then the polyanilinewas characterized via Fourier transform infrared spectroscopy (FTIR), UV-visiblespectroscopy and scanning electron microscopy (SEM). Based on the water solublepolyaniline film, a quartz crystal microbalance (QCM) sensor for trimethylamine detectionwas fabricated and its characteristics were examined. The sensor consisted of one quartzcrystal oscillator coated with the polyaniline film for sensing and the other one forreference. Pretreated with trimethylamine, the QCM sensor had an excellent linearsensitivity to trimethylamine. Easily recovered by N2 purgation, the response of the sensorexhibited a good repeatability. Responses of the sensor to trimethylamine, ethanol and ethylacetate were compared, and the results showed that the response was related to the polarityof the analyte vapor. Experimental result also showed that the sensitivity of the sensor wasrelatively stable within one month. The simple and feasible method to prepare and coat thepolyaniline sensing film makes it promising for mass production.

  7. Bio-inspired Edible Superhydrophobic Interface for Reducing Residual Liquid Food.

    PubMed

    Li, Yao; Bi, Jingran; Wang, Siqi; Zhang, Tan; Xu, Xiaomeng; Wang, Haitao; Cheng, Shasha; Zhu, Bei-Wei; Tan, Mingqian

    2018-03-07

    Significant wastage of residual liquid food, such as milk, yogurt, and honey, in food containers has attracted great attention. In this work, a bio-inspired edible superhydrophobic interface was fabricated using U.S. Food and Drug Administration-approved and edible honeycomb wax, arabic gum, and gelatin by a simple and low-cost method. The bio-inspired edible superhydrophobic interface showed multiscale structures, which were similar to that of a lotus leaf surface. This bio-inspired edible superhydrophobic interface displayed high contact angles for a variety of liquid foods, and the residue of liquid foods could be effectively reduced using the bio-inspired interface. To improve the adhesive force of the superhydrophobic interface, a flexible edible elastic film was fabricated between the interface and substrate material. After repeated folding and flushing for a long time, the interface still maintained excellent superhydrophobic property. The bio-inspired edible superhydrophobic interface showed good biocompatibility, which may have potential applications as a functional packaging interface material.

  8. USE OF DIAGNODENT® FOR DIAGNOSIS OF NON-CAVITATED OCCLUSALDENTIN CARIES

    PubMed Central

    Costa, Ana Maria; de Paula, Lilian Marly; Bezerra, Ana Cristina Barreto

    2008-01-01

    The purpose of this study was to evaluate the use of a laser fluorescence device for detection of occlusal caries in permanent teeth. One hundred and ninety-nine non-cavitated teeth from 26 patients aged 10 to 13 years were selected. After dental prophylaxis, two previously calibrated dentists examined the teeth. Visual inspection, radiographic examination and laser measurements were performed under standardized conditions. The validation method was cavity preparation with a small cone-shaped diamond bur, when the two examiners agreed about the presence of dentin caries. It was found that the laser detection method produced high values of sensitivity (0.93) and specificity (0.75) and a moderate positive predictive value (0.63). The laser device showed the lowest value of likelihood ratio (3.68). Kappa coefficient showed good repeatability for all methods. Although the laser device had an acceptable performance, this equipment should be used as an adjunct method to visual inspection to avoid false positive results. PMID:19089284

  9. Patterns of vegetation and grasshopper community composition.

    PubMed

    Kemp, W P; Harvey, S J; O'Neill, K M

    1990-06-01

    A study was conducted to evaluate differences in rangeland grasshopper communities over environmental gradients in Gallatin Valley, Montana, USA. The concept of habitat type (Daubenmire 1966) was used as a basis for discriminating between groupings of patches based on vegetation. A total of 39 patches were selected that represented five recognized grassland habitat types (Mueggler and Stewart 1980), as well as two disturbed types (replanting within a known habitat type). Repeated sampling in 1988 of both the insect and plant communities yielded a total of 40 grasshopper (19 664 individuals) and 97 plant species. Detrended Correspondence Analysis (DCA) indicated that patch classifications based on presence and percent cover of plants were appropriate and showed good between-group (habitat type) separation for patches along gradients of precipitation/elevation and plant community complexity. Results from undisturbed habitats showed that plant and grasshopper species composition changed over observed environmental gradients and suggested that habitat type influenced not only species presence, but also relative abundance. Discussion is presented that relates results with patch-use and core and satellite species paradigms.

  10. Radiotherapy dosimetry using a commercial OSL system.

    PubMed

    Viamonte, A; da Rosa, L A R; Buckley, L A; Cherpak, A; Cygler, J E

    2008-04-01

    A commercial optically stimulated luminescence (OSL) system developed for radiation protection dosimetry by Landauer, Inc., the InLight microStar reader, was tested for dosimetry procedures in radiotherapy. The system uses carbon-doped aluminum oxide, Al2O3:C, as a radiation detector material. Using this OSL system, a percent depth dose curve for 60Co gamma radiation was measured in solid water. Field size and SSD dependences of the detector response were also evaluated. The dose response relationship was investigated between 25 and 400 cGy. The decay of the response with time following irradiation and the energy dependence of the Al2O3:C OSL detectors were also measured. The results obtained using OSL dosimeters show good agreement with ionization chamber and diode measurements carried out under the same conditions. Reproducibility studies show that the response of the OSL system to repeated exposures is 2.5% (1sd), indicating a real possibility of applying the Landauer OSL commercial system for radiotherapy dosimetric procedures.

  11. Accurate dew-point measurement over a wide temperature range using a quartz crystal microbalance dew-point sensor

    NASA Astrophysics Data System (ADS)

    Kwon, Su-Yong; Kim, Jong-Chul; Choi, Buyng-Il

    2008-11-01

    Quartz crystal microbalance (QCM) dew-point sensors are based on frequency measurement, and so have fast response time, high sensitivity and high accuracy. Recently, we have reported that they have the very convenient attribute of being able to distinguish between supercooled dew and frost from a single scan through the resonant frequency of the quartz resonator as a function of the temperature. In addition to these advantages, by using three different types of heat sinks, we have developed a QCM dew/frost-point sensor with a very wide working temperature range (-90 °C to 15 °C). The temperature of the quartz surface can be obtained effectively by measuring the temperature of the quartz crystal holder and using temperature compensation curves (which showed a high level of repeatability and reproducibility). The measured dew/frost points showed very good agreement with reference values and were within ±0.1 °C over the whole temperature range.

  12. Upper eyelid abscess as a late complication of frontal sinus trauma

    PubMed Central

    Adriana, Iliescu Daniela; Cornel, Stefan; Mihaela, Timaru Cristina; Speranta, Schmitzer; Algerino, De Simone; Mehdi, Batras; Elena, Zeca Cristina; Bogdan, Maciuceanu-Zarnescu Mircea

    2015-01-01

    The authors report a case of upper eyelid abscess in a 30 year old male that presented in the ophthalmology department with complains of recurrent eyelid pyosis, hyperaemia and swelling that started 2 months earlier and that did not ease to repeated courses of antibiotic therapy. The reported history of the patient revealed frontal sinus trauma that occurred 5 years before and that required surgical treatment (fixation with titan plaque and screws) with total healing and giving no further complains over the next years. The present cranial CT imaging showed intraorbital fat infiltration with displacement of one orbital arcade screw. Clinical findings showed normal ocular mobility. Antibiotic treatment and screw extraction through eyelid fistula improved the outcome but did not resolve the fistulous communication. Final management involved surgical removal of orbital arcade plaque and remaining screw and excision of fistula tract. The postoperative outcome was very good and the fistula remained closed but left the patient with an upper eyelid retraction which will require oculoplastic surgery in the future. PMID:29450319

  13. A Novel Nanofilm Sensor Based on Poly-(Alizarin Red)/Fe3O4 Magnetic Nanoparticles-Multiwalled Carbon Nanotubes Composite Material for Determination of Nitrite.

    PubMed

    Qu, Jianying; Dong, Ying; Yong, Wang; Lou, Tongfang; Du, Xueping; Qu, Jianhang

    2016-03-01

    Fe3O4 magnetic nanoparticles were synthesized by chemical co-precipitation with sodium citrate as surfactant and were characterized by FT-IR spectrometer, X-ray diffraction and transmission electron microscopy. A novel nitrite sensor was fabricated by electropolymerization of alizarin red on the surface of glassy carbon electrode modified with Fe3O4-multiwalled carbon nanotubes composite nanofilm. Under the optimal experimental conditions, it was showed that the proposed sensor exhibited good electrocatalytic activity to the oxidation of nitrite, and the peak current increased linearly with the nitrite concentration from 9.64 x 10(-6) mol x L(-1) to 1.30 x 10(-3) mol x L(-1) (R = 0.9976) with a detection limit of 1.19 x 10(-6) mol x L(-1) (S/N = 3). This sensor showed excellent sensitivity, wide linear range, stability and repeatability for nitrite determination with potential applications.

  14. Immobilization of pectinase on oxidized pulp fiber and its application in whitewater treatment.

    PubMed

    Wu, Rina; He, Bei-Hai; Zhao, Guang-Lei; Qian, Li-Ying; Li, Xiao-Feng

    2013-09-12

    Modified pulp fiber was originally used as a new type of carrier for pectinase immobilization. Pulp fiber was oxidized by sodium periodate to produce aldehyde groups for covalently binding with amino groups of pectinase. Results showed that the enzymatic activity of immobilized pectinase on pulp fiber reached 65 μgg(-1)min(-1) when immobilization pH value, temperature and time were of 7.0, 20 °C and 15 min, respectively. The immobilized pectinase showed higher thermo stability in a wider temperature range of 40-70 °C than its free type and its optimal pH shifted from 8.0 to 8.8. Furthermore, the immobilized pectinase exhibited good operational stability. When employed in whitewater treatment of papermaking industry, it still efficiently decreased the cationic demand after operating repeatedly for six batches. The results obtained demonstrate a promising route to prepare available, cheap and biodegradable carrier for immobilizing enzymes with potential application in wastewater treatment in papermaking industry. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Molecular characterization and distribution of a 145-bp tandem repeat family in the genus Populus.

    PubMed

    Rajagopal, J; Das, S; Khurana, D K; Srivastava, P S; Lakshmikumaran, M

    1999-10-01

    This report aims to describe the identification and molecular characterization of a 145-bp tandem repeat family that accounts for nearly 1.5% of the Populus genome. Three members of this repeat family were cloned and sequenced from Populus deltoides and P. ciliata. The dimers of the repeat were sequenced in order to confirm the head-to-tail organization of the repeat. Hybridization-based analysis using the 145-bp tandem repeat as a probe on genomic DNA gave rise to ladder patterns which were identified to be a result of methylation and (or) sequence heterogeneity. Analysis of the methylation pattern of the repeat family using methylation-sensitive isoschizomers revealed variable methylation of the C residues and lack of methylation of the A residues. Sequence comparisons between the monomers revealed a high degree of sequence divergence that ranged between 6% and 11% in P. deltoides and between 4.2% and 8.3% in P. ciliata. This indicated the presence of sub-families within the 145-bp tandem family of repeats. Divergence was mainly due to the accumulation of point mutations and was concentrated in the central region of the repeat. The 145-bp tandem repeat family did not show significant homology to known tandem repeats from plants. A short stretch of 36 bp was found to show homology of 66.7% to a centromeric repeat from Chironomus plumosus. Dot-blot analysis and Southern hybridization data revealed the presence of the repeat family in 13 of the 14 Populus species examined. The absence of the 145-bp repeat from P. euphratica suggested that this species is relatively distant from other members of the genus, which correlates with taxonomic classifications. The widespread occurrence of the tandem family in the genus indicated that this family may be of ancient origin.

  16. Multilevel mixed effects parametric survival models using adaptive Gauss-Hermite quadrature with application to recurrent events and individual participant data meta-analysis.

    PubMed

    Crowther, Michael J; Look, Maxime P; Riley, Richard D

    2014-09-28

    Multilevel mixed effects survival models are used in the analysis of clustered survival data, such as repeated events, multicenter clinical trials, and individual participant data (IPD) meta-analyses, to investigate heterogeneity in baseline risk and covariate effects. In this paper, we extend parametric frailty models including the exponential, Weibull and Gompertz proportional hazards (PH) models and the log logistic, log normal, and generalized gamma accelerated failure time models to allow any number of normally distributed random effects. Furthermore, we extend the flexible parametric survival model of Royston and Parmar, modeled on the log-cumulative hazard scale using restricted cubic splines, to include random effects while also allowing for non-PH (time-dependent effects). Maximum likelihood is used to estimate the models utilizing adaptive or nonadaptive Gauss-Hermite quadrature. The methods are evaluated through simulation studies representing clinically plausible scenarios of a multicenter trial and IPD meta-analysis, showing good performance of the estimation method. The flexible parametric mixed effects model is illustrated using a dataset of patients with kidney disease and repeated times to infection and an IPD meta-analysis of prognostic factor studies in patients with breast cancer. User-friendly Stata software is provided to implement the methods. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Utilization of optical emission endpoint in photomask dry etch processing

    NASA Astrophysics Data System (ADS)

    Faure, Thomas B.; Huynh, Cuc; Lercel, Michael J.; Smith, Adam; Wagner, Thomas

    2002-03-01

    Use of accurate and repeatable endpoint detection during dry etch processing of photomask is very important for obtaining good mask mean-to-target and CD uniformity performance. It was found that the typical laser reflectivity endpoint detecting system used on photomask dry etch systems had several key limitations that caused unnecessary scrap and non-optimum image size performance. Consequently, work to develop and implement use of a more robust optical emission endpoint detection system for chrome dry etch processing of photomask was performed. Initial feasibility studies showed that the emission technique was sensitive enough to monitor pattern loadings on contact and via level masks down to 3 percent pattern coverage. Additional work was performed to further improve this to 1 percent pattern coverage by optimizing the endpoint detection parameters. Comparison studies of mask mean-to-target performance and CD uniformity were performed with the use of optical emission endpoint versus laser endpoint for masks built using TOK IP3600 and ZEP 7000 resist systems. It was found that an improvement in mean-to-target performance and CD uniformity was realized on several types of production masks. In addition, part-to-part endpoint time repeatability was found to be significantly improved with the use of optical emission endpoint.

  18. Single-cell forensic short tandem repeat typing within microfluidic droplets.

    PubMed

    Geng, Tao; Novak, Richard; Mathies, Richard A

    2014-01-07

    A short tandem repeat (STR) typing method is developed for forensic identification of individual cells. In our strategy, monodisperse 1.5 nL agarose-in-oil droplets are produced with a high frequency using a microfluidic droplet generator. Statistically dilute single cells, along with primer-functionalized microbeads, are randomly compartmentalized in the droplets. Massively parallel single-cell droplet polymerase chain reaction (PCR) is performed to transfer replicas of desired STR targets from the single-cell genomic DNA onto the coencapsulated microbeads. These DNA-conjugated beads are subsequently harvested and reamplified under statistically dilute conditions for conventional capillary electrophoresis (CE) STR fragment size analysis. The 9-plex STR profiles of single cells from both pure and mixed populations of GM09947 and GM09948 human lymphoid cells show that all alleles are correctly called and allelic drop-in/drop-out is not observed. The cell mixture study exhibits a good linear relationship between the observed and input cell ratios in the range of 1:1 to 10:1. Additionally, the STR profile of GM09947 cells could be deduced even in the presence of a high concentration of cell-free contaminating 9948 genomic DNA. Our method will be valuable for the STR analysis of samples containing mixtures of cells/DNA from multiple contributors and for low-concentration samples.

  19. Clustered Regularly Interspaced Short Palindromic Repeats Are emm Type-Specific in Highly Prevalent Group A Streptococci.

    PubMed

    Zheng, Po-Xing; Chan, Yuen-Chi; Chiou, Chien-Shun; Chiang-Ni, Chuan; Wang, Shu-Ying; Tsai, Pei-Jane; Chuang, Woei-Jer; Lin, Yee-Shin; Liu, Ching-Chuan; Wu, Jiunn-Jong

    2015-01-01

    Clustered regularly interspaced short palindromic repeats (CRISPR) are the bacterial adaptive immune system against foreign nucleic acids. Given the variable nature of CRISPR, it could be a good marker for molecular epidemiology. Group A streptococcus is one of the major human pathogens. It has two CRISPR loci, including CRISPR01 and CRISPR02. The aim of this study was to analyze the distribution of CRISPR-associated gene cassettes (cas) and CRISPR arrays in highly prevalent emm types. The cas cassette and CRISPR array in two CRISPR loci were analyzed in a total of 332 strains, including emm1, emm3, emm4, emm12, and emm28 strains. The CRISPR type was defined by the spacer content of each CRISPR array. All strains had at least one cas cassette or CRISPR array. More than 90% of the spacers were found in one emm type, specifically. Comparing the consistency between emm and CRISPR types by Simpson's index of diversity and the adjusted Wallace coefficient, CRISPR01 type was concordant to emm type, and CRISPR02 showed unidirectional congruence to emm type, suggesting that at least for the majority of isolates causing infection in high income countries, the emm type can be inferred from CRISPR analysis, which can further discriminate isolates sharing the same emm type.

  20. New Tunneling Features in Polar III-Nitride Resonant Tunneling Diodes

    NASA Astrophysics Data System (ADS)

    Encomendero, Jimy; Faria, Faiza Afroz; Islam, S. M.; Protasenko, Vladimir; Rouvimov, Sergei; Sensale-Rodriguez, Berardi; Fay, Patrick; Jena, Debdeep; Xing, Huili Grace

    2017-10-01

    For the past two decades, repeatable resonant tunneling transport of electrons in III-nitride double barrier heterostructures has remained elusive at room temperature. In this work we theoretically and experimentally study III-nitride double-barrier resonant tunneling diodes (RTDs), the quantum transport characteristics of which exhibit new features that are unexplainable using existing semiconductor theory. The repeatable and robust resonant transport in our devices enables us to track the origin of these features to the broken inversion symmetry in the uniaxial crystal structure, which generates built-in spontaneous and piezoelectric polarization fields. Resonant tunneling transport enabled by the ground state as well as by the first excited state is demonstrated for the first time over a wide temperature window in planar III-nitride RTDs. An analytical transport model for polar resonant tunneling heterostructures is introduced for the first time, showing a good quantitative agreement with experimental data. From this model we realize that tunneling transport is an extremely sensitive measure of the built-in polarization fields. Since such electric fields play a crucial role in the design of electronic and photonic devices, but are difficult to measure, our work provides a completely new method to accurately determine their magnitude for the entire class of polar heterostructures.

  1. Genetic polymorphisms of short tandem repeat loci D13S305, D13S631 and D13S634 in the Han population of Tianjin, China.

    PubMed

    Shi, Yunfang; Li, Xiaozhou; Ju, Duan; Li, Yan; Zhang, Xiuling; Zhang, Ying

    2015-08-01

    Short tandem repeat (STR) markers, also known as microsatellites, are extensively used in mapping studies, forensics and disease diagnosis due to their small dimension and low mutation and high polymorphism rates. In recent years quantitative fluorescence polymerase chain reaction (QF-PCR) has been successfully used to amplify STR markers in the prenatal diagnosis of common chromosomal abnormalities. This method provides a diagnosis of common aneuploidies 24-48 h after sampling with low error rates and cost; however, the size of different alleles, frequency, heterozygosity and distribution of STR markers vary among different populations. In the present study three STR markers, D13S305, D13S631 and D13S634, on chromosome 13 were analyzed in 350 unrelated individuals (200 males and 150 females) from the Han population of Tianjin, China using QF-PCR. Eleven, seven and 11 alleles of each marker were observed, respectively. The frequencies of the genotypes were in good agreement with Hardy-Weinberg equilibrium (P>0.05). The results showed that these three STR markers were highly polymorphic in the Han population of Tianjin, China. The study has provided basic data for use in the prenatal diagnosis of Patau syndrome.

  2. Genetic polymorphisms of short tandem repeat loci D13S305, D13S631 and D13S634 in the Han population of Tianjin, China

    PubMed Central

    SHI, YUNFANG; LI, XIAOZHOU; JU, DUAN; LI, YAN; ZHANG, XIULING; ZHANG, YING

    2015-01-01

    Short tandem repeat (STR) markers, also known as microsatellites, are extensively used in mapping studies, forensics and disease diagnosis due to their small dimension and low mutation and high polymorphism rates. In recent years quantitative fluorescence polymerase chain reaction (QF-PCR) has been successfully used to amplify STR markers in the prenatal diagnosis of common chromosomal abnormalities. This method provides a diagnosis of common aneuploidies 24–48 h after sampling with low error rates and cost; however, the size of different alleles, frequency, heterozygosity and distribution of STR markers vary among different populations. In the present study three STR markers, D13S305, D13S631 and D13S634, on chromosome 13 were analyzed in 350 unrelated individuals (200 males and 150 females) from the Han population of Tianjin, China using QF-PCR. Eleven, seven and 11 alleles of each marker were observed, respectively. The frequencies of the genotypes were in good agreement with Hardy-Weinberg equilibrium (P>0.05). The results showed that these three STR markers were highly polymorphic in the Han population of Tianjin, China. The study has provided basic data for use in the prenatal diagnosis of Patau syndrome. PMID:26622392

  3. Optical coherence tomography in retinitis pigmentosa: reproducibility and capacity to detect macular and retinal nerve fiber layer thickness alterations.

    PubMed

    Garcia-Martin, Elena; Pinilla, Isabel; Sancho, Eva; Almarcegui, Carmen; Dolz, Isabel; Rodriguez-Mena, Diego; Fuertes, Isabel; Cuenca, Nicolas

    2012-09-01

    To evaluate the ability of time-domain and Fourier-domain optical coherence tomographies (OCTs) to detect macular and retinal nerve fiber layer atrophies in retinitis pigmentosa (RP). To test the intrasession reproducibility using three OCT instruments (Stratus, Cirrus, and Spectralis). Eighty eyes of 80 subjects (40 RP patients and 40 healthy subjects) underwent a visual field examination, together with 3 macular scans and 3 optic disk evaluations by the same experienced examiner using 3 OCT instruments. Differences between healthy and RP eyes were compared. The relationship between measurements with each OCT instrument was evaluated. Repeatability was studied by intraclass correlation coefficients and coefficients of variation. Macular and retinal nerve fiber layer atrophies were detected in RP patients for all OCT parameters. Macular and retinal nerve fiber layer thicknesses, as determined by the different OCTs, were correlated but significantly different (P < 0.05). Reproducibility was moderately high using Stratus, good using Cirrus and Spectralis, and excellent using the Tru-track technology of Spectralis. In RP eyes, measurements showed higher variability compared with healthy eyes. Differences in thickness measurements existed between OCT instruments, despite there being a high degree of correlation. Fourier-domain OCT can be considered a valid and repeatability technique to detect retinal nerve fiber layer atrophy in RP patients.

  4. Diagnostics and Identification of Injection Duration of Common Rail Diesel Injectors

    NASA Astrophysics Data System (ADS)

    Krogerus, Tomi R.; Huhtala, Kalevi J.

    2018-02-01

    In this paper, we study the diagnostics and identification of injection duration of common rail (CR) diesel pilot injectors of dual-fuel engines. In these pilot injectors, the injected volume is small and the repeatability of the injections and identification of the drifts of the injectors are important factors, which need to be taken into account in achieving good repeatability (shot-to-shot with every cylinder) and therefore a well-balanced engine and reduced overall wear. A diagnostics method based on analysis of CR pressure signal with experimental verification results is presented. Using the developed method, the relative duration of injection events can be identified. In the method, the pressure signal during the injection is first extracted after the control of each injection event. After that, the signal is normalized and filtered. Then a derivative of the filtered signal is calculated. Change in the derivative of the filtered signal larger than a predefined threshold indicates an injection event which can be detected and its relative duration can be identified. The efficacy of the proposed diagnostics method is presented with the experimental results, which show that the developed method detects drifts in injection duration and the magnitude of drift. According to the result, ≥ 10 μs change (2%, 500 μs) in injection time can be identified.

  5. Development and validation of a liquid chromatography method for the simultaneous determination of eight water-soluble vitamins in multivitamin formulations and human urine.

    PubMed

    Patil, Suyog S; Srivastava, Ashwini K

    2013-01-01

    A simple, precise, and rapid RPLC method has been developed without incorporation of any ion-pair reagent for the simultaneous determination of vitamin C (C) and seven B-complex vitamins, viz, thiamine hydrochloride (B1), pyridoxine hydrochloride (B6), nicotinamide (B3), cyanocobalamine (B12), folic acid, riboflavin (B2), and 4-aminobenzoic acid (Bx). Separations were achieved within 12.0 min at 30 degrees C by gradient elution on an RP C18 column using a mobile phase consisting of a mixture of 15 mM ammonium formate buffer and 0.1% triethylamine adjusted to pH 4.0 with formic acid and acetonitrile. Simultaneous UV detection was performed at 275 and 360 nm. The method was validated for system suitability, LOD, LOQ, linearity, precision, accuracy, specificity, and robustness in accordance with International Conference on Harmonization guidelines. The developed method was implemented successfully for determination of the aforementioned vitamins in pharmaceutical formulations containing an individual vitamin, in their multivitamin combinations, and in human urine samples. The calibration curves for all analytes showed good linearity, with coefficients of correlation higher than 0.9998. Accuracy, intraday repeatability (n = 6), and interday repeatability (n = 7) were found to be satisfactory.

  6. Synthesis, Characterization, Antioxidant Status, and Toxicity Study of Vanadium-Rutin Complex in Balb/c Mice.

    PubMed

    Roy, Souvik; Majumdar, Sumana; Singh, Amit Kumar; Ghosh, Balaram; Ghosh, Nilanjan; Manna, Subhadip; Chakraborty, Tania; Mallick, Sougato

    2015-08-01

    A new trend was developed for the formation of a complex between vanadium and flavonoid derivatives in order to increase the intestinal absorption and to reduce the toxicity of vanadium compounds. The vanadium-rutin complex was characterized by several spectroscopic techniques like ultraviolet (UV)-visible, Fourier transform infrared (FTIR), NMR, mass spectrometry, and microscopic evaluation by scanning electron microscopy. The mononuclear complex was formed by the interaction between vanadium and rutin with 1:2 metal to ligand stoichiometry. Antioxidant activity of the complex was evaluated by 1,1-diphenyl-2 picrylhydrazyl, ferric-reducing power, and 2,2'-azin-obis 3-ethylbenzothiazoline-6-sulphonic acid methods. It was shown that radical scavenging activity and ferric-reducing potential of free rutin was lower as compared with vanadium-rutin complex. The study was also investigated for oral acute toxicity and 28 days repeated oral subacute toxicity study of vanadium-rutin complex in balb/c mice. The vanadium-rutin complex showed mortality at a dose of 120 mg/kg in the balb/c mice. In 28 days repeated oral toxicity study, vanadium-rutin complex was administered to both sex of balb/c mice at dose levels of 90, 45, and 20 ppm, respectively. In addition, subacute toxicity study of vanadium-rutin complex (at 90 ppm dose level) showed increase levels of white blood cell (WBC), total bilirubin, alanine aminotransferase (ALT), alkaline phosphatase (ALP), aspartate aminotransferase (AST), creatinine, and blood urea nitrogen and decrease level of total protein (TP) as compared with control group. Histopathological study of vanadium-rutin showed structural alteration in the liver, kidney, and stomach at 90 ppm dose level. No observed toxic level of vanadium-rutin complex at 20 ppm dose level could be good for further study.

  7. Reproducibility analysis of upper limbs reachable workspace, and effects of acquisition protocol, sex and hand dominancy.

    PubMed

    Clément, Julien; Raison, Maxime; Rouleau, Dominique M

    2018-02-08

    None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, particularly in terms of reproducibility. Therefore, this study aims to evaluate the reproducibility of the reachable workspace over a period of several weeks, and to assess the effects of two proposed acquisition protocols, as well as those of gender, and hand dominancy. Shoulder movements were recorded using a motion capture system on 10 female and 10 male healthy subjects during a random protocol, i.e. simply asking them to achieve the farthest points they could reach with their hands, and during a standardized protocol, i.e. asking them to perform predefined shoulder elevations while keeping their trunk and elbow straight. The standardized protocol was repeated 7 weeks later. Repeated measures showed no significant difference, good to excellent intraclass correlation coefficients (0.46-0.81) and small bias (0.0-1.2%). The random protocol provided significantly lower and more scattered values for the reachable workspace (80.0 ± 22.6% vs. 91.0 ± 8.1%, p = .004), whereas gender and hand-dominancy had no effect. This study showed that the reachable workspace was highly reliable over a period of 7 weeks and that both upper limbs provided similar results. It could be used to monitor various pathologies of the upper limbs and to assess treatment efficiency, using a subject's healthy limb as reference. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Review: Game theory of public goods in one-shot social dilemmas without assortment.

    PubMed

    Archetti, Marco; Scheuring, István

    2012-04-21

    We review the theory of public goods in biology. In the N-person prisoner's dilemma, where the public good is a linear function of the individual contributions, cooperation requires some form of assortment, for example due to kin discrimination, population viscosity or repeated interactions. In most social species ranging from bacteria to humans, however, public goods are usually a non-linear function of the contributions, which makes cooperation possible without assortment. More specifically, a polymorphic state can be stable in which cooperators and non-cooperators coexist. The existence of mixed equilibria in public goods games is a fundamental result in the study of cooperation that has been overlooked so far, because of the disproportionate attention given to the two- and N-person prisoner's dilemma. Methods and results from games with pairwise interactions or linear benefits cannot, in general, be extended to the analysis of public goods. Game theory helps explain the production of public goods in one-shot, N-person interactions without assortment, it leads to predictions that can be easily tested and allows a prescriptive approach to cooperation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Error Patterns in Research Papers by Pacific Rim Students.

    ERIC Educational Resources Information Center

    Crowe, Chris

    By looking for patterns of errors in the research papers of Asian students, educators can uncover pedagogical strategies to help students avoid repeating such errors. While a good deal of research has identified a number of sentence-level problems which are typical of Asian students writing in English, little attempt has been made to consider the…

  10. Is It Wrong for Us to Want Good Things? The Origins of Gompers Charter Middle School

    ERIC Educational Resources Information Center

    Mehan, Hugh B.; Chang, Gordon C.

    2011-01-01

    This paper documents the initial process by which a San Diego middle school, located in a low-income and predominantly Hispanic neighborhood and repeatedly failing to meet No Child Left Behind provisions, restructured into an academically rigorous, detracked charter school. The discussion of the political experience and working relationships…

  11. Repeatability, Reproducibility, Separative Power and Subjectivity of Different Fish Morphometric Analysis Methods

    PubMed Central

    Takács, Péter

    2016-01-01

    We compared the repeatability, reproducibility (intra- and inter-measurer similarity), separative power and subjectivity (measurer effect on results) of four morphometric methods frequently used in ichthyological research, the “traditional” caliper-based (TRA) and truss-network (TRU) distance methods and two geometric methods that compare landmark coordinates on the body (GMB) and scales (GMS). In each case, measurements were performed three times by three measurers on the same specimen of three common cyprinid species (roach Rutilus rutilus (Linnaeus, 1758), bleak Alburnus alburnus (Linnaeus, 1758) and Prussian carp Carassius gibelio (Bloch, 1782)) collected from three closely-situated sites in the Lake Balaton catchment (Hungary) in 2014. TRA measurements were made on conserved specimens using a digital caliper, while TRU, GMB and GMS measurements were undertaken on digital images of the bodies and scales. In most cases, intra-measurer repeatability was similar. While all four methods were able to differentiate the source populations, significant differences were observed in their repeatability, reproducibility and subjectivity. GMB displayed highest overall repeatability and reproducibility and was least burdened by measurer effect. While GMS showed similar repeatability to GMB when fish scales had a characteristic shape, it showed significantly lower reproducability (compared with its repeatability) for each species than the other methods. TRU showed similar repeatability as the GMS. TRA was the least applicable method as measurements were obtained from the fish itself, resulting in poor repeatability and reproducibility. Although all four methods showed some degree of subjectivity, TRA was the only method where population-level detachment was entirely overwritten by measurer effect. Based on these results, we recommend a) avoidance of aggregating different measurer’s datasets when using TRA and GMS methods; and b) use of image-based methods for morphometric surveys. Automation of the morphometric workflow would also reduce any measurer effect and eliminate measurement and data-input errors. PMID:27327896

  12. CGG Repeats in the 5’UTR of FMR1 RNA Regulate Translation of Other RNAs Localized in the Same RNA Granules

    PubMed Central

    Rovozzo, René; Korza, George; Baker, Mei W.; Li, Meng; Bhattacharyya, Anita; Barbarese, Elisa; Carson, John H.

    2016-01-01

    CGG repeats in the 5’UTR of Fragile X Mental Retardation 1 (FMR1) RNA mediate RNA localization and translation in granules. Large expansions of CGG repeats (> 200 repeats) in FMR1, referred to as full mutations, are associated with fragile X syndrome (FXS). Smaller expansions (55–200 repeats), referred to as premutations, are associated with fragile X tremor ataxia syndrome (FXTAS) and fragile X premature ovarian insufficiency (FXPOI). TMPyP4 is a porphyrin ring compound that destabilizes CGG repeat RNA secondary structure. Here we show that exogenous CGG repeat RNA by itself, lacking the FMRP ORF, microinjected into hippocampal neurons is localized in RNA granules and inhibits translation of ARC RNA, which is localized in the same granules. TMPyP4 rescues translation of ARC RNA in granules. We also show that in human premutation fibroblasts with endogenous CGG repeat expansions in the FMR1 gene, translation of ARC RNA is inhibited and calcium homeostasis is disrupted and both phenotypes are rescued by TMPyP4. Inhibition of granule translation by expanded CGG repeats and rescue of granule translation by TMPy4, represent potential pathogenic mechanism and therapeutic strategy, respectively, for FXTAS and FXPOI. PMID:28005950

  13. The reliability and validity of fatigue measures during short-duration maximal-intensity intermittent cycling.

    PubMed

    Glaister, Mark; Stone, Michael H; Stewart, Andrew M; Hughes, Michael; Moir, Gavin L

    2004-08-01

    The purpose of the present study was to assess the reliability and validity of fatigue measures, as derived from 4 separate formulae, during tests of repeat sprint ability. On separate days over a 3-week period, 2 groups of 7 recreationally active men completed 6 trials of 1 of 2 maximal (20 x 5 seconds) intermittent cycling tests with contrasting recovery periods (10 or 30 seconds). All trials were conducted on a friction-braked cycle ergometer, and fatigue scores were derived from measures of mean power output for each sprint. Apart from formula 1, which calculated fatigue from the percentage difference in mean power output between the first and last sprint, all remaining formulae produced fatigue scores that showed a reasonably good level of test-retest reliability in both intermittent test protocols (intraclass correlation range: 0.78-0.86; 95% likely range of true values: 0.54-0.97). Although between-protocol differences in the magnitude of the fatigue scores suggested good construct validity, within-protocol differences highlighted limitations with each formula. Overall, the results support the use of the percentage decrement score as the most valid and reliable measure of fatigue during brief maximal intermittent work.

  14. An experimental and finite element poroelastic creep response analysis of an intervertebral hydrogel disc model in axial compression.

    PubMed

    Silva, P; Crozier, S; Veidt, M; Pearcy, M J

    2005-07-01

    A hydrogel intervertebral disc (IVD) model consisting of an inner nucleus core and an outer anulus ring was manufactured from 30 and 35% by weight Poly(vinyl alcohol) hydrogel (PVA-H) concentrations and subjected to axial compression in between saturated porous endplates at 200 N for 11 h, 30 min. Repeat experiments (n=4) on different samples (N=2) show good reproducibility of fluid loss and axial deformation. An axisymmetric nonlinear poroelastic finite element model with variable permeability was developed using commercial finite element software to compare axial deformation and predicted fluid loss with experimental data. The FE predictions indicate differential fluid loss similar to that of biological IVDs, with the nucleus losing more water than the anulus, and there is overall good agreement between experimental and finite element predicted fluid loss. The stress distribution pattern indicates important similarities with the biological IVD that includes stress transference from the nucleus to the anulus upon sustained loading and renders it suitable as a model that can be used in future studies to better understand the role of fluid and stress in biological IVDs.

  15. Nutrition training for chefs: taste as an essential determinant of choice.

    PubMed

    Palmer, J; Leontos, C

    1995-12-01

    The primary objective of Project LEAN (Low-fat Eating for Americans Now), a social marketing initiative of the Henry J. Kaiser Family Foundation, is to help Americans reduce their fat intake to less than 30% of total energy. In Las Vegas, Nev, one of the 10 community sites selected to implement this goal, Las Vegas LEAN acted to change the food environment for restaurant patrons. This program empowered chefs to use their culinary expertise in developing good-tasting, low-fat menu items. The literature shows that consumers, despite verbalizing health concerns, choose food on the basis of taste. This ambivalence between belief and behavior demonstrates the need for innovative culinary techniques to develop food dishes that consumers will not only accept, but will enjoy and order repeatedly. Entrepreneurial dietitians, thus, have an opportunity to market nutrition skills to restaurants and hotels wishing to implement low-fat cuisine with good taste. Our intervention demonstrated that nutrition education for chefs is the key to long-term and successful menu changes. If taste is what consumers are seeking in low-fat items, and improved taste will finally get ambivalent consumers to change their eating behavior, enlisting the expertise of chefs is key.

  16. [Study on TLC identification and UPLC determination method of atractylenolide in Atractylodes macrocephala].

    PubMed

    Zhao, Yu-Jiao; Xu, Wen-Hui; Shen, Xiao-Li; Tian, Jun-Sheng; Qin, Xue-Mei

    2017-02-01

    This research is to establish TLC and UPLC methods for simultaneous determination of 3 atractylenolides in Atractylodes macrocephala. Silica gel GF254 plate was used for identification of A. macrocephala, and UPLC-PDA gradient elution method was used to simultaneously determine atractylenolide Ⅰ, Ⅱ and Ⅲ. The Waters BEH C₁₈ column(2.1 mm×100 mm,1.7 μm)with acetonitrile-water as mobile phase and the wavelength of UV detector of 235 nm were performed. The quality control study showed that the characteristic for identification by TLC was distinct and highly specific. The method of content determination was in accordance with the regulations. The quantitative evaluation of atractylenolide Ⅰ,Ⅱ and Ⅲ was in good linear range(r>0.999 9), and the average recovery was 93.48%(RSD 1.4%),94.97%(RSD 1.6%),92.71%(RSD 1.2%),respectively. TLC identification was in good specificity and repeatability, and the UPLC-PDA method for the simultaneous determination of 3 atractylenolides was simple and reliable for the quality control of A.macrocephala. Copyright© by the Chinese Pharmaceutical Association.

  17. Layer-by-Layer Self-Assembling Gold Nanorods and Glucose Oxidase onto Carbon Nanotubes Functionalized Sol-Gel Matrix for an Amperometric Glucose Biosensor.

    PubMed

    Wu, Baoyan; Hou, Shihua; Miao, Zhiying; Zhang, Cong; Ji, Yanhong

    2015-09-18

    A novel amperometric glucose biosensor was fabricated by layer-by-layer self-assembly of gold nanorods (AuNRs) and glucose oxidase (GOD) onto single-walled carbon nanotubes (SWCNTs)-functionalized three-dimensional sol-gel matrix. A thiolated aqueous silica sol containing SWCNTs was first assembled on the surface of a cleaned Au electrode, and then the alternate self-assembly of AuNRs and GOD were repeated to assemble multilayer films of AuNRs-GOD onto SWCNTs-functionalized silica gel for optimizing the biosensor. Among the resulting glucose biosensors, the four layers of AuNRs-GOD-modified electrode showed the best performance. The sol-SWCNTs-(AuNRs- GOD)₄/Au biosensor exhibited a good linear range of 0.01-8 mM glucose, high sensitivity of 1.08 μA/mM, and fast amperometric response within 4 s. The good performance of the proposed glucose biosensor could be mainly attributed to the advantages of the three-dimensional sol-gel matrix and stereo self-assembly films, and the natural features of one-dimensional nanostructure SWCNTs and AuNRs. This study may provide a new facile way to fabricate the enzyme-based biosensor with high performance.

  18. Indirect electrocatalytic determination of choline by monitoring hydrogen peroxide at the choline oxidase-prussian blue modified iron phosphate nanostructures.

    PubMed

    Zhang, Hui; Yin, Yajing; Wu, Ping; Cai, Chenxin

    2012-01-15

    Choline, as a marker of cholinergic activity in brain tissue, is very important in biological and clinical analysis, especially in the clinical detection of the neurodegenerative disorders disease. This work presents an electrochemical approach for the detection of choline based on prussian blue modified iron phosphate nanostructures (PB-FePO(4)). The obtained nanostructures showed a good catalysis toward the electroreduction of H(2)O(2), and an amperometric choline biosensor was developed by immobilizing choline oxidase on the PB-FePO(4) nanostructures. The biosensor exhibited a rapid response (ca. 2s), low detection limit (0.4±0.05 μM), wide linear range (2 μM to 3.2 mM), high sensitivity (~75.2 μAm M(-1) cm(-2)), as well as good stability and repeatability. In addition, the common interfering species, such as ascorbic acid, uric acid and 4-acetamidophenol did not cause obvious interference due to the low detection potential (-0.05 V versus saturated calomel electrode). This nanostructure could be used as a promise platform for the construction of other oxidase-based biosensors. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. An indentation depth-force sensing wheeled probe for abnormality identification during minimally invasive surgery.

    PubMed

    Liu, H; Puangmali, P; Zbyszewski, D; Elhage, O; Dasgupta, P; Dai, J S; Seneviratne, L; Althoefer, K

    2010-01-01

    This paper presents a novel wheeled probe for the purpose of aiding a surgeon in soft tissue abnormality identification during minimally invasive surgery (MIS), compensating the loss of haptic feedback commonly associated with MIS. Initially, a prototype for validating the concept was developed. The wheeled probe consists of an indentation depth sensor employing an optic fibre sensing scheme and a force/torque sensor. The two sensors work in unison, allowing the wheeled probe to measure the tool-tissue interaction force and the rolling indentation depth concurrently. The indentation depth sensor was developed and initially tested on a homogenous silicone phantom representing a good model for a soft tissue organ; the results show that the sensor can accurately measure the indentation depths occurring while performing rolling indentation, and has good repeatability. To validate the ability of the wheeled probe to identify abnormalities located in the tissue, the device was tested on a silicone phantom containing embedded hard nodules. The experimental data demonstrate that recording the tissue reaction force as well as rolling indentation depth signals during rolling indentation, the wheeled probe can rapidly identify the distribution of tissue stiffness and cause the embedded hard nodules to be accurately located.

  20. Simultaneous determination of sucralose and related compounds by high-performance liquid chromatography with evaporative light scattering detection.

    PubMed

    Yan, Wenwu; Wang, Nani; Zhang, Peimin; Zhang, Jiajie; Wu, Shuchao; Zhu, Yan

    2016-08-01

    Sucralose is widely used in food and beverages as sweetener. Current synthesis approaches typically provide sucralose products with varying levels of related chlorinated carbohydrates which can affect the taste and flavor-modifying properties of sucralose. Quantification of related compounds in sucralose is often hampered by the lack of commercially available standards. In this work, nine related compounds were purified (purity>97%) and identified by liquid chromatography-mass spectrometry (LC-MS) and nuclear magnetic resonance (NMR), then a rapid and simple HPLC coupled with evaporative light scattering detection (ELSD) method has been developed for the simultaneous determination of sucralose and related compounds. Under optimized conditions, the method showed good linearity in the range of 2-600μgmL(-1) with determination coefficients R(2)⩾0.9990. Moreover, low limits of detection in the range of 0.5-2.0μgmL(-1) and good repeatability (RSD<3%, n=6) were obtained. Recoveries were from 96.8% to 101.2%. Finally, the method has been successfully applied to sucralose quality control and purification process monitoring. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Halloysite clay nanotubes and platinum nanoparticles dispersed in ionic liquid applied in the development of a catecholamine biosensor.

    PubMed

    Brondani, Daniela; Scheeren, Carla Weber; Dupont, Jairton; Vieira, Iolanda Cruz

    2012-08-21

    Halloysite clay nanotubes were used as a support for the immobilization of the enzyme peroxidase from clover sprouts (Trifolium), and employed together with platinum nanoparticles in 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid (Pt-BMI·PF(6)) in the development of a new biosensor for the determination of catecholamines by square-wave voltammetry. Under optimized conditions, the analytical curves showed detection limits of 0.05, 0.06, 0.07, 0.12 μM for dopamine, isoproterenol, dobutamine and epinephrine, respectively. The biosensor demonstrated high sensitivity, good repeatability and reproducibility, and long-term stability (18% decrease in response over 150 days). A recovery study of dopamine in pharmaceutical samples gave values from 97.5 to 101.4%. The proposed biosensor was successfully applied to the determination of dopamine in pharmaceutical samples, with a maximum relative error of ±1.0% in relation to the standard (spectrophotometric) method. The good analytical performance of the proposed method can be attributed to the efficient immobilization of the peroxidase in the nanoclay, and the facilitation of electron transfer between the protein and the electrode surface due to the presence of the Pt nanoparticles and ionic liquid.

  2. FBG based high sensitive pressure sensor and its low-cost interrogation system with enhanced resolution

    NASA Astrophysics Data System (ADS)

    Pachava, Vengal Rao; Kamineni, Srimannarayana; Madhuvarasu, Sai Shankar; Putha, Kishore; Mamidi, Venkata Reddy

    2015-12-01

    A fiber Bragg grating (FBG) pressure sensor with high sensitivity and resolution has been designed and demonstrated. The sensor is configured by firmly fixing the FBG with a metal bellows structure. The sensor works by means of measuring the Bragg wavelength shift of the FBG with respect to pressure change. From the experimental results, the pressure sensitivity of the sensor is found to be 90.6 pm/psi, which is approximately 4000 times as that of a bare fiber Bragg grating. A very good linearity of 99.86% is observed between the Bragg wavelength of the FBG and applied pressure. The designed sensor shows good repeatability with a negligible hysteresis error of ± 0.29 psi. A low-cost interrogation system that includes a long period grating (LPG) and a photodiode (PD) accompanied with simple electronic circuitry is demonstrated for the FBG sensor, which enables the sensor to attain high resolution of up to 0.025 psi. Thermal-strain cross sensitivity of the FBG pressure sensor is compensated using a reference FBG temperature sensor. The designed sensor can be used for liquid level, specific gravity, and static/dynamic low pressure measurement applications.

  3. Hydrophilic interaction ultra-performance liquid chromatography coupled with triple-quadrupole tandem mass spectrometry for highly rapid and sensitive analysis of underivatized amino acids in functional foods.

    PubMed

    Zhou, Guisheng; Pang, Hanqing; Tang, Yuping; Yao, Xin; Mo, Xuan; Zhu, Shaoqing; Guo, Sheng; Qian, Dawei; Qian, Yefei; Su, Shulan; Zhang, Li; Jin, Chun; Qin, Yong; Duan, Jin-ao

    2013-05-01

    This work presented a new analytical methodology based on hydrophilic interaction ultra-performance liquid chromatography coupled with triple-quadrupole tandem mass spectrometry in multiple-reaction monitoring mode for analysis of 24 underivatized free amino acids (FAAs) in functional foods. The proposed method was first reported and validated by assessing the matrix effects, linearity, limit of detections and limit of quantifications, precision, repeatability, stability and recovery of all target compounds, and it was used to determine the nutritional substances of FAAs in ginkgo seeds and further elucidate the nutritional value of this functional food. The result showed that ginkgo seed turned out to be a good source of FAAs with high levels of several essential FAAs and to have a good nutritional value. Furthermore, the principal component analysis was performed to classify the ginkgo seed samples on the basis of 24 FAAs. As a result, the samples could be mainly clustered into three groups, which were similar to areas classification. Overall, the presented method would be useful for the investigation of amino acids in edible plants and agricultural products.

  4. Comparative analysis of tandem repeats from hundreds of species reveals unique insights into centromere evolution.

    PubMed

    Melters, Daniël P; Bradnam, Keith R; Young, Hugh A; Telis, Natalie; May, Michael R; Ruby, J Graham; Sebra, Robert; Peluso, Paul; Eid, John; Rank, David; Garcia, José Fernando; DeRisi, Joseph L; Smith, Timothy; Tobias, Christian; Ross-Ibarra, Jeffrey; Korf, Ian; Chan, Simon W L

    2013-01-30

    Centromeres are essential for chromosome segregation, yet their DNA sequences evolve rapidly. In most animals and plants that have been studied, centromeres contain megabase-scale arrays of tandem repeats. Despite their importance, very little is known about the degree to which centromere tandem repeats share common properties between different species across different phyla. We used bioinformatic methods to identify high-copy tandem repeats from 282 species using publicly available genomic sequence and our own data. Our methods are compatible with all current sequencing technologies. Long Pacific Biosciences sequence reads allowed us to find tandem repeat monomers up to 1,419 bp. We assumed that the most abundant tandem repeat is the centromere DNA, which was true for most species whose centromeres have been previously characterized, suggesting this is a general property of genomes. High-copy centromere tandem repeats were found in almost all animal and plant genomes, but repeat monomers were highly variable in sequence composition and length. Furthermore, phylogenetic analysis of sequence homology showed little evidence of sequence conservation beyond approximately 50 million years of divergence. We find that despite an overall lack of sequence conservation, centromere tandem repeats from diverse species showed similar modes of evolution. While centromere position in most eukaryotes is epigenetically determined, our results indicate that tandem repeats are highly prevalent at centromeres of both animal and plant genomes. This suggests a functional role for such repeats, perhaps in promoting concerted evolution of centromere DNA across chromosomes.

  5. Comparative analysis of tandem repeats from hundreds of species reveals unique insights into centromere evolution

    PubMed Central

    2013-01-01

    Background Centromeres are essential for chromosome segregation, yet their DNA sequences evolve rapidly. In most animals and plants that have been studied, centromeres contain megabase-scale arrays of tandem repeats. Despite their importance, very little is known about the degree to which centromere tandem repeats share common properties between different species across different phyla. We used bioinformatic methods to identify high-copy tandem repeats from 282 species using publicly available genomic sequence and our own data. Results Our methods are compatible with all current sequencing technologies. Long Pacific Biosciences sequence reads allowed us to find tandem repeat monomers up to 1,419 bp. We assumed that the most abundant tandem repeat is the centromere DNA, which was true for most species whose centromeres have been previously characterized, suggesting this is a general property of genomes. High-copy centromere tandem repeats were found in almost all animal and plant genomes, but repeat monomers were highly variable in sequence composition and length. Furthermore, phylogenetic analysis of sequence homology showed little evidence of sequence conservation beyond approximately 50 million years of divergence. We find that despite an overall lack of sequence conservation, centromere tandem repeats from diverse species showed similar modes of evolution. Conclusions While centromere position in most eukaryotes is epigenetically determined, our results indicate that tandem repeats are highly prevalent at centromeres of both animal and plant genomes. This suggests a functional role for such repeats, perhaps in promoting concerted evolution of centromere DNA across chromosomes. PMID:23363705

  6. [Aesthetic criteria in surgical treatment of hypospadias in children].

    PubMed

    Kozyrev, G V; Protasov, A A; Nikolaev, V V; Abdullaev, F K; Abdulkarimov, G A; Karmanov, M E

    2017-10-01

    Aesthetically acceptable cosmetic results of surgical correction of external genital organ defects are important for treatment evaluation along with well-known criteria of good functional outcomes.The purpose of this study was to improve the results of treating children with hypospadias by improving the assessment of results and introducing multi-step correction modalities. From 2013 to 2015, 476 patients with various forms of hypospadias were treated at the Department of Uroandrology of RCCH. The patients age ranged from 1 year to 17 years (mean age 3 years). All patients were divided into 3 groups depending on the form of hypospadias and type of treatment. They included patients with distal forms of hypospadias (group1, n=270), proximal forms (group 2, n=112) and patients with stem and penoscrotal hypospadias who underwent 3-6 operations before admission (group 3, n=94). The study evaluated both functional and cosmetic results. Cosmetic appearance was assessed using the HOPE scoring system [2]. Despite the difference in surgical methods used for all types of hypospadias, good cosmetic results have been achieved in the majority of patients (65%). Functional outcomes differed depending on the form of hypospadias. In primary patients with distal and proximal forms of hypospadias, good results were achieved in 96% and 77% of patients, respectively. At the same time, 72% of patients who underwent repeat interventions had good results, which is comparable to the group of primary patients with proximal forms. The results of treating patients after repeat/failed surgery confirm the high effectiveness of our surgical methods (the Bracka two-stage graft repair, buccal mucosa hypospadias repair, reconstruction with scrotal skin flaps, correction of scrotal transposition). Using the HOPE scoring system to assess cosmetic results helps motivate surgeons to achieve the best treatment results.

  7. The development and validation of a custom built device for assessing frontal knee joint laxity.

    PubMed

    Ismail, Shiek Abdullah; Simic, Milena; Clarke, Jillian L; Lopes, Thiago Jambo Alves; Pappas, Evangelos

    2017-12-01

    This study reports the development and validation of a quantitative technique of assessing frontal knee joint laxity through a custom built device named KLICP. The objectives of this study were to determine: (i) the intra- and inter-rater reliability and (ii) the validity of the device when compared to real time ultrasound. Twenty-five participants had their frontal knee joint laxity assessed by the KLICP, by manual varus/valgus tests and by ultrasound. Two raters independently assessed laxity manually by three repeated measurements, repeated at least 48h later. Results were validated by comparing them to the medial and lateral joint space opening measured by the ultrasound. Intraclass correlation coefficients and standard error of measurement reliability were calculated. Pearson's correlation coefficients were calculated to determine the correlation between the KLICP and the joint space. Intra-rater reliability (intra-session) for each rater was good on both sessions (0.91-0.98), intra-rater reliability (inter-sessions) was moderate to good (0.62-0.87), and inter-rater reliability (intra-session) was good (0.75-0.80). There is low agreement for intra-rater (inter-session) and for inter-rater (intra-session) reliability. The KLICP measurement has a significant positive fair to moderate correlation to the ultrasound measurement at the left (r: 0.61, p: 0.01) and right (r: 0.48, p: 0.02) knee in the valgus direction and at the left (r: 0.51, p: 0.01) and right (r: 0.39, p: 0.05) knee in the varus direction. There is low agreement between the KLICP and the RTU. Reliability and agreement was good only when measured for intra-rater, within session. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. A new family of dispersed repeats from Brassica nigra: characterization and localization.

    PubMed

    Kapila, R; Negi, M S; This, P; Delseny, M; Srivastava, P S; Lakshmikumaran, M

    1996-11-01

    The 459-bp HindIII (pBN-4) and the 1732-bp Eco RI (pBNE8) fragments from the Brassica nigra genome were cloned and shown to be members of a dispersed repeat family. Of the three major diploid Brassica species, the repeat pBN-4 was found to be highly specific for the B. nigra genome. The family also hybridized to Sinapis arvensis showing that B. nigra had a closer relationship with the S. arvensis genome than with B. oleracea or B. campestris. The clone pBNE8 showed homology to a number of tRNA species indicating that this family of repeats may have originated from a tRNA sequence. The species-specific 459-bp repeat pBN-4 was localized on the B. nigra chromosomes using monosomic addition lines. In addition to the localization of pBN-4, the chromosomal distribution of two other species-specific repeats, pBN34 and pBNBH35 (reported earlier), was studied. The dispersed repeats pBN-4 and pBNBH35 were found to be present on all of the chromosomes, whereas the tandem repeat pBN34 was localized on two chromosomes.

  9. Does it really feel the same? Changes in life satisfaction following repeated life events.

    PubMed

    Luhmann, Maike; Eid, Michael

    2009-08-01

    Unemployment, divorce, and marriage are common life events for most people in Western societies. In a longitudinal study, the authors investigated how these life events affect life satisfaction when they occur repeatedly. Data came from the German Socio-Economic Panel, a large-scale representative panel study, and were analyzed using multilevel modeling. Results showed that, in general, life satisfaction decreases with repeated unemployment (sensitization). For repeated divorces, life satisfaction is higher at the second divorce than it had been at the first divorce (adaptation). Finally, life satisfaction is similar at repeated marriages. Neuroticism, extraversion, and gender accounted for interindividual differences in changes in life satisfaction. For instance, the general sensitization pattern associated with repeated unemployment was less pronounced for women. The authors also found main effects of age and the duration of the first event on general differences in life satisfaction. Finally, those with repeated events generally report lower life satisfaction than those with only one occasion of these events, even before the first event actually occurred. Findings show that repeated events can have very different effects on life satisfaction that depend on the nature of the event.

  10. Fabrication of a Delaying Biodegradable Magnesium Alloy-Based Esophageal Stent via Coating Elastic Polymer

    PubMed Central

    Yuan, Tianwen; Yu, Jia; Cao, Jun; Gao, Fei; Zhu, Yueqi; Cheng, Yingsheng; Cui, Wenguo

    2016-01-01

    Esophageal stent implantation can relieve esophageal stenosis and obstructions in benign esophageal strictures, and magnesium alloy stents are a good candidate because of biodegradation and biological safety. However, biodegradable esophageal stents show a poor corrosion resistance and a quick loss of mechanical support in vivo. In this study, we chose the elastic and biodegradable mixed polymer of Poly(ε-caprolactone) (PCL) and poly(trimethylene carbonate) (PTMC) as the coated membrane on magnesium alloy stents for fabricating a fully biodegradable esophageal stent, which showed an ability to delay the degradation time and maintain mechanical performance in the long term. After 48 repeated compressions, the mechanical testing demonstrated that the PCL-PTMC-coated magnesium stents possess good flexibility and elasticity, and could provide enough support against lesion compression when used in vivo. According to the in vitro degradation evaluation, the PCL-PTMC membrane coated on magnesium was a good material combination for biodegradable stents. During the in vivo evaluation, the proliferation of the smooth muscle cells showed no signs of cell toxicity. Histological examination revealed the inflammation scores at four weeks in the magnesium-(PCL-PTMC) stent group were similar to those in the control group (p > 0.05). The α-smooth muscle actin layer in the media was thinner in the magnesium-(PCL-PTMC) stent group than in the control group (p < 0.05). Both the epithelial and smooth muscle cell layers were significantly thinner in the magnesium-(PCL-PTMC) stent group than in the control group. The stent insertion was feasible and provided reliable support for at least four weeks, without causing severe injury or collagen deposition. Thus, this stent provides a new stent for the treatment of benign esophageal stricture and a novel research path in the development of temporary stents in other cases of benign stricture. PMID:28773505

  11. Intra- and Inter-rater Agreement of Superior Vena Cava Flow and Right Ventricular Outflow Measurements in Late Preterm and Term Neonates.

    PubMed

    Mahoney, Liam; Fernandez-Alvarez, Jose R; Rojas-Anaya, Hector; Aiton, Neil; Wertheim, David; Seddon, Paul; Rabe, Heike

    2018-02-24

    To explore the intra- and inter-rater agreement of superior vena cava (SVC) flow and right ventricular (RV) outflow in healthy and unwell late preterm neonates (33-37 weeks' gestational age), term neonates (≥37 weeks' gestational age), and neonates receiving total-body cooling. The intra- and inter-rater agreement (n = 25 and 41 neonates, respectively) rates for SVC flow and RV outflow were determined by echocardiography in healthy and unwell late preterm and term neonates with the use of Bland-Altman plots, the repeatability coefficient, the repeatability index, and intraclass correlation coefficients. The intra-rater repeatability index values were 41% for SVC flow and 31% for RV outflow, with intraclass correlation coefficients indicating good agreement for both measures. The inter-rater repeatability index values for SVC flow and RV outflow were 63% and 51%, respectively, with intraclass correlation coefficients indicating moderate agreement for both measures. If SVC flow or RV outflow is used in the hemodynamic treatment of neonates, sequential measurements should ideally be performed by the same clinician to reduce potential variability. © 2018 by the American Institute of Ultrasound in Medicine.

  12. Influence of radiographic techniques on the measurement of femoral anteversion angles and a conformation score of pelvic limbs in Labrador retrievers.

    PubMed

    Mostafa, Ayman A; Cunningham, Devin P; Boudrieau, Randy J; Kowaleski, Michael P; Griffon, Dominique J

    2018-04-01

    To determine repeatability of and correlation between 2 radiographic measurements of femoral anteversion angles (FAA) and to determine their influence on a score derived from tibial plateau angle (TPA) and FAA to predict the risk of cranial cruciate ligament disease (CCLD). Prospective clinical study. Forty-eight Labrador retrievers with or without CCLD. FAA and CCLD scores were calculated for each limb from extended pelvic radiographs (t-FAA) or angled (a-FAA) projections of the femur by 3 investigators. One investigator repeated measurements twice. Data were analyzed for repeatability, correlation between t-FAA and a-FAA, and their influence on CCLD scores. FAA correlated most strongly with the distance between the femoral head and the femoral axis on mediolateral radiographs, a measurement with excellent repeatability. t-FAA and a-FAA correlated with each other (r > 0.79, P < .0001), although t-FAA were about 1° greater than a-FAA (P = .01). Intrainvestigator and interinvestigator repeatability of the CCLD score was fair when derived from t-FAA and good to excellent when derived from a-FAA. CCLD scores differed between radiographic techniques but led to different predictions in only 9 (10%) limbs, all with lower TPA and CCLD scores than the rest of the population. a-FAA correlated strongly with t-FAA and improved the repeatability of CCLD scores within and between investigators. A craniocaudal angled beam projection of the femur is a suitable alternative to a ventrodorsal pelvic radiograph when measuring FAA and may improve the repeatability and positive predictive value of CCLD scores. © 2018 The American College of Veterinary Surgeons.

  13. Test-retest repeatability of child's respiratory symptoms and perceived indoor air quality - comparing self- and parent-administered questionnaires.

    PubMed

    Lampi, Jussi; Ung-Lanki, Sari; Santalahti, Päivi; Pekkanen, Juha

    2018-02-09

    Questionnaires can be used to assess perceived indoor air quality and symptoms in schools. Questionnaires for primary school aged children have traditionally been parent-administered, but self-administered questionnaires would be easier to administer and may yield as good, if not better, information. Our aim was to compare the repeatability of self- and parent-administered indoor air questionnaires designed for primary school aged pupils. Indoor air questionnaire with questions on child's symptoms and perceived indoor air quality in schools was sent to parents of pupils aged 7-12 years in two schools and again after two weeks. Slightly modified version of the questionnaire was administered to pupils aged 9-12 years in another two schools and repeated after a week. 351 (52%) parents and 319 pupils (86%) answered both the first and the second questionnaire. Test-retest repeatability was assessed with intra-class correlation (ICC) and Cohen's kappa coefficients (k). Test-retest repeatability was generally between 0.4-0.7 (ICC; k) in both self- and parent-administered questionnaire. In majority of the questions on symptoms and perceived indoor air quality test-retest repeatability was at the same level or slightly better in self-administered compared to parent-administered questionnaire. Agreement of self- and parent administered questionnaires was generally < 0.4 (ICC; k) in reported symptoms and 0.4-0.6 (ICC; k) in perceived indoor air quality. Children aged 9-12 years can give as, or even more, repeatable information about their respiratory symptoms and perceived indoor air quality than their parents. Therefore, it may be possible to use self-administered questionnaires in future studies also with children.

  14. A CGG-repeat expansion mutation in ZNF713 causes FRA7A: association with autistic spectrum disorder in two families.

    PubMed

    Metsu, Sofie; Rainger, Jacqueline K; Debacker, Kim; Bernhard, Birgitta; Rooms, Liesbeth; Grafodatskaya, Daria; Weksberg, Rosanna; Fombonne, Eric; Taylor, Martin S; Scherer, Stephen W; Kooy, R Frank; FitzPatrick, David R

    2014-11-01

    We report de novo occurrence of the 7p11.2 folate-sensitive fragile site FRA7A in a male with an autistic spectrum disorder (ASD) due to a CGG-repeat expansion mutation (∼450 repeats) in a 5' intron of ZNF713. This expanded allele showed hypermethylation of the adjacent CpG island with reduced ZNF713 expression observed in a proband-derived lymphoblastoid cell line (LCL). His unaffected mother carried an unmethylated premutation (85 repeats). This CGG-repeat showed length polymorphism in control samples (five to 22 repeats). In a second unrelated family, three siblings with ASD and their unaffected father were found to carry FRA7A premutations, which were partially or mosaically methylated. In one of the affected siblings, mitotic instability of the premutation was observed. ZNF713 expression in LCLs in this family was increased in three of these four premutation carriers. A firm link cannot yet be established between ASD and the repeat expansion mutation but plausible pathogenic mechanisms are discussed. © 2014 WILEY PERIODICALS, INC.

  15. Deep landscape update of dispersed and tandem repeats in the genome model of the red jungle fowl, Gallus gallus, using a series of de novo investigating tools.

    PubMed

    Guizard, Sébastien; Piégu, Benoît; Arensburger, Peter; Guillou, Florian; Bigot, Yves

    2016-08-19

    The program RepeatMasker and the database Repbase-ISB are part of the most widely used strategy for annotating repeats in animal genomes. They have been used to show that avian genomes have a lower repeat content (8-12 %) than the sequenced genomes of many vertebrate species (30-55 %). However, the efficiency of such a library-based strategies is dependent on the quality and completeness of the sequences in the database that is used. An alternative to these library based methods are methods that identify repeats de novo. These alternative methods have existed for a least a decade and may be more powerful than the library based methods. We have used an annotation strategy involving several complementary de novo tools to determine the repeat content of the model genome galGal4 (1.04 Gbp), including identifying simple sequence repeats (SSRs), tandem repeats and transposable elements (TEs). We annotated over one Gbp. of the galGal4 genome and showed that it is composed of approximately 19 % SSRs and TEs repeats. Furthermore, we estimate that the actual genome of the red jungle fowl contains about 31-35 % repeats. We find that library-based methods tend to overestimate TE diversity. These results have a major impact on the current understanding of repeats distributions throughout chromosomes in the red jungle fowl. Our results are a proof of concept of the reliability of using de novo tools to annotate repeats in large animal genomes. They have also revealed issues that will need to be resolved in order to develop gold-standard methodologies for annotating repeats in eukaryote genomes.

  16. Comparison of Automated Analysis of Cirrus HD-OCT™ Spectral Domain Optical Coherence Tomography with Stereo Photos of the Optic Disc

    PubMed Central

    Sharma, Ashish; Oakley, Jonathan D.; Schiffman, Joyce C.; Budenz, Donald L.; Anderson, Douglas R.

    2010-01-01

    OBJECTIVE To evaluate a new automated analysis of optic disc images obtained by spectral domain optical coherence tomography (SD-OCT). Areas of the optic disc, cup, and neural rim in SD-OCT images were compared with these areas from stereoscopic photographs, to represent the current traditional optic nerve evaluation. The repeatability of measurements by each method was determined and compared. DESIGN Evaluation of diagnostic technology. PARTICIPANTS 119 healthy eyes, 23 eyes with glaucoma, and 7 suspect eyes METHODS Optic disc and cup margins were traced from stereoscopic photographs by three individuals independently. Optic disc margins and rim widths were determined automatically in SD-OCT. A subset of photographs was examined and traced a second time, and duplicate SD-OCT images were also analyzed. MAIN OUTCOME MEASUREMENTS Agreement among photograph readers, between duplicate readings, and between SD-OCT and photographs were quantified by the intraclass correlation coefficient (ICC), by the root mean square (RMS), and the standard deviation (SD) of the differences. RESULTS Optic disc areas tended to be slightly larger when judged in photographs than by SD-OCT, while cup areas were similar. Cup and optic disc areas showed good correlation (0.8) between average photographic reading and SD-OCT, but only fair correlation of rim areas (0.4). The SD-OCT was highly reproducible (ICC of 0.96 to 0.99). Each reader was also consistent with himself on duplicate readings of 21 photographs (ICC 0.80 to 0.88 for rim area, 0.95 to 0.98 for all other measurements), but reproducibility was not as good as SD-OCT. Measurements derived from SD-OCT did not differ from photographic readings more than the readings of photographs by different readers differed from each other. CONCLUSIONS Designation of the cup and optic disc boundaries by an automated analysis of SD-OCT was within the range of variable designations by different readers from color stereoscopic photographs, but use of different landmarks typically made the designation of the optic disc size somewhat smaller in the automated analysis. There was better repeatability among measurements from SD-OCT than from among readers of photographs. The repeatability of automated measurement of SD-OCT images is promising for use both in diagnosis and in monitoring of progression. PMID:21397334

  17. [Clinical analysis of 104 cases of overdose in suicide attempts].

    PubMed

    Ozaki, Yoshimi; Nakata, Yasuki; Kameoka, Masafumi; Hayashi, Nobuhiro; Nakayama, Yusuke; Yagi, Keiichi

    2007-10-01

    Patients who have attempted suicide by taking medicines are frequently admitted to emergency and critical care medical centers. These patients usually have both physical and mental problems. Some try repeatedly to commit suicide. In this study, to ascertain how to prevent repeated attempts of suicide, we investigated the clinical characteristics of patients attempting suicide by taking overdoses of medicine. One hundred and four cases of suicide attempted by taking an overdose of medicine, seen at The Emergency and Critical Care Medical Center, Tottori University Hospital, Tottori from April 2005 to March 2006, were investigated in this retrospective study. Patients were 25 males (24%), and 79 females (76%). Eighty one patients (77.9%) had regularly been receiving psychiatric care, with neurotic disorders being the most common psychiatric condition. Thirty eight patients (36.5%) had repeated suicide attempts by taking an overdose of medicine. In 2005, there were 9 patients (9.4%) who had repeatedly consulted our critical care medical center. Most of these patients were females who had previously consulted a psychiatric clinic and had diagnoses of stress-related or personality disorders. In this study, we demonstrated that it is important to build a good relationship between psychiatrists and emergency doctors. As well, to prevent repeated incidents of taking an overdose of medicines in a suicide attempt, it is important to ensure that medical and psychosocial support are positively applied to patients with such tendencies.

  18. Preventive effect of curcumin and its highly bioavailable preparation on hearing loss induced by single or repeated exposure to noise: A comparative and mechanistic study.

    PubMed

    Yamaguchi, Taro; Yoneyama, Masanori; Onaka, Yusuke; Imaizumi, Atsushi; Ogita, Kiyokazu

    2017-08-01

    We sought to determine the preventive effects of curcumin and its highly bioavailable preparation on noise-induced hearing loss in a novel murine model of permanent hearing loss developed by repeated exposure to noise. Upon exposure to noise (8-kHz octave band noise, 90 dB sound pressure level, 1 h), hearing ability was impaired in a temporary and reversible manner. During repeated noise exposure (1-h exposure per day, 5 days), there was a progressive increase in the auditory threshold shift at 12 and 20 kHz. The threshold shift persisted for at least 6 days after noise exposure. Oral administration of curcumin for 3 days before and each day during noise exposure significantly alleviated the hearing loss induced by repeated noise exposure. Curcumin abolished intranuclear translocation of nuclear factor-κB-p65 and generation of 4-hydroxynonenal-adducted proteins found in the cochlea after noise exposure. Theracurmin ® , a highly absorbable and bioavailable preparation of curcumin, had strong preventive effects on hearing loss induced by repeated noise exposure. Together, these data suggest that curcumin exerts a preventive effect on noise-induced hearing loss and is therefore a good therapeutic candidate for preventing sensorineural hearing loss. Copyright © 2017 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  19. [Myasthenia gravis with the electrographic response of a myasthenic syndrome. Report of a case].

    PubMed

    Werneck, L C; Bittencourt, P C; Nóvak, E M

    1985-06-01

    It is reported a case of a 61 years-old man with progressive asthenia, disfagia, disphonia and diplopia, of variable intensity during the day, who had a very good response to anticolinesterasic drugs and corticosteroids. The repetitive stimulation tests at low frequency, resulted in large increment (maximum 275%) of the basal voltage after exercise. At high frequency he also had a large increment. Radiological and laboratory investigation three times in a seven-year period was normal, without evidence of any neoplasia. Muscle biopsy showed a type II muscle fiber atrophy. The repetitive stimulation tests repeated three times, was typical of myasthenia gravis in one occasion and in the other two, typical of myasthenic syndrome (increment of 418%). A discussion about other cases with similar findings is made after a review of the literature.

  20. RHETT/EPDM Performance Characterization

    NASA Technical Reports Server (NTRS)

    Haag, T.; Osborn, M.

    1998-01-01

    The 0.6 kW Electric Propulsion Demonstration Module (EPDM) flight thruster system was tested in a large vacuum facility for performance measurements and functional checkout. The thruster was operated at a xenon flow rate of 3.01 mg/s, which was supplied through a self-contained propellant system. All power was provided through a flight-packaged power processing unit, which was mounted in vacuum on a cold plate. The thruster was cycled through 34 individual startup and shutdown sequences. Operating periods ranged from 3 to 3600 seconds. The system responded promptly to each command sequence and there were no involuntary shutdowns. Direct thrust measurements indicated that steady state thrust was temperature sensitive, and varied from a high of 41.7 mN at 16 C, to a low of 34.8 mN at 110 C. Short duration thruster firings showed rapid response and good repeatability.

  1. Ultra-Shallow Depth Profiling of Arsenic Implants in Silicon by Hydride Generation-Inductively Coupled Plasma Atomic Emission Spectrometry

    NASA Astrophysics Data System (ADS)

    Matsubara, Atsuko; Kojima, Hisao; Itoga, Toshihiko; Kanehori, Keiichi

    1995-08-01

    High resolution depth profiling of arsenic (As) implanted into silicon wafers by a chemical technique is described. Silicon wafers are precisely etched through repeated oxidation by hydrogen peroxide solution and dissolution of the oxide by hydrofluoric acid solution. The etched silicon thickness is determined by inductively-coupled plasma atomic emission spectrometry (ICP-AES). Arsenic concentration is determined by hydride generation ICP-AES (HG-ICP-AES) with prereduction using potassium iodide. The detection limit of As in a 4-inch silicon wafer is 2.4×1018 atoms/cm3. The etched silicon thickness is controlled to less than 4±2 atomic layers. Depth profiling of an ultra-shallow As diffusion layer with the proposed method shows good agreement with profiling using the four-probe method or secondary ion mass spectrometry.

  2. Validated ¹H and 13C Nuclear Magnetic Resonance Methods for the Quantitative Determination of Glycerol in Drug Injections.

    PubMed

    Lu, Jiaxi; Wang, Pengli; Wang, Qiuying; Wang, Yanan; Jiang, Miaomiao

    2018-05-15

    In the current study, we employed high-resolution proton and carbon nuclear magnetic resonance spectroscopy (¹H and 13 C NMR) for quantitative analysis of glycerol in drug injections without any complex pre-treatment or derivatization on samples. The established methods were validated with good specificity, linearity, accuracy, precision, stability, and repeatability. Our results revealed that the contents of glycerol were convenient to calculate directly via the integration ratios of peak areas with an internal standard in ¹H NMR spectra, while the integration of peak heights were proper for 13 C NMR in combination with an external calibration of glycerol. The developed methods were both successfully applied in drug injections. Quantitative NMR methods showed an extensive prospect for glycerol determination in various liquid samples.

  3. Improving the Dynamic Emissivity Measurement Above 1000 K by Extending the Spectral Range

    NASA Astrophysics Data System (ADS)

    Urban, D.; Krenek, S.; Anhalt, K.; Taubert, D. R.

    2018-01-01

    To improve the dynamic emissivity measurement, which is based on the laser-flash method, an array spectrometer is characterized regarding its spectral radiance responsivity for a spectrally resolved emissivity measurement above 1000 K in the wavelength range between 550 nm and 1100 nm. Influences like dark signals, the nonlinearity of the detector, the size-of-source effect, wavelength calibration and the spectral radiance responsivity of the system are investigated to obtain an uncertainty budget for the spectral radiance and emissivity measurements. Uncertainties for the spectral radiance of lower than a relative 2 % are achieved for wavelengths longer than 550 nm. Finally, the spectral emissivity of a graphite sample was determined in the temperature range between 1000 K and 1700 K, and the experimental data show a good repeatability and agreement with literature data.

  4. Determination of capsaicinoids in topical cream by liquid-liquid extraction and liquid chromatography.

    PubMed

    Kaale, Eliangiringa; Van Schepdael, Ann; Roets, Eugène; Hoogmartens, Jos

    2002-11-07

    A reversed-phase liquid chromatography (LC) method has been developed, optimised and validated for the separation and quantitation of capsaicin (CP) and dihydrocapsaicin (DHCP) in a topical cream formulation. Sample preparation involves liquid-liquid extraction prior to LC analysis. The method uses a Hypersil C(18) BDS, 5 micrometer, 250x4.6 mm I.D. column maintained at 35 degrees C. The mobile phase comprises methanol, water, acetonitrile (ACN) and acetic acid (47:42:10:1, v/v/v/v) at a flow rate of 1.0 ml/min. Robustness was evaluated by performing a central composite face-centred design (CCF) experiment. The method shows good selectivity, linearity, sensitivity and repeatability. The conditions allow the separation and quantitation of CP and DHCP without interference from the other substances contained in the cream.

  5. On the non-Poissonian repetition pattern of FRB121102

    NASA Astrophysics Data System (ADS)

    Oppermann, Niels; Yu, Hao-Ran; Pen, Ue-Li

    2018-04-01

    The Fast Radio Burst FRB121102 has been observed to repeat in an irregular fashion. Using published timing data of the observed bursts, we show that Poissonian statistics are not a good description of this random process. As an alternative, we suggest to describe the intervals between bursts with a Weibull distribution with a shape parameter smaller than one, which allows for the clustered nature of the bursts. We quantify the amount of clustering using the parameters of the Weibull distribution and discuss the consequences that it has for the detection probabilities of future observations and for the optimization of observing strategies. Allowing for this generalization, we find a mean repetition rate of r=5.7^{+3.0}_{-2.0} per day and index k=0.34^{+0.06}_{-0.05} for a correlation function ξ(t) = (t/t0)k - 1.

  6. Molecular characterization of the canine mitochondrial DNA control region for forensic applications.

    PubMed

    Eichmann, Cordula; Parson, Walther

    2007-09-01

    The canine mitochondrial DNA (mtDNA) control region of 133 dogs living in the area around Innsbruck, Austria was sequenced. A total of 40 polymorphic sites were observed in the first hypervariable segment and 15 in the second, which resulted in the differentiation of 40 distinct haplotypes. We observed five nucleotide positions that were highly polymorphic within different haplogroups, and they represent good candidates for mtDNA screening. We found five point heteroplasmic positions; all located in HVS-I and a polythymine region in HVS-II, the latter often being associated with length heteroplasmy. In contrast to human mtDNA, the canine control region contains a hypervariable 10 nucleotide repeat region, which is located between the two hypervariable regions. In our population sample, we observed eight different repeat types, which we characterized by direct sequencing and fragment length analysis. The discrimination power of the canine mtDNA control region was 0.93, not taking the polymorphic repeat region into consideration.

  7. Maximum likelihood decoding analysis of Accumulate-Repeat-Accumulate Codes

    NASA Technical Reports Server (NTRS)

    Abbasfar, Aliazam; Divsalar, Dariush; Yao, Kung

    2004-01-01

    Repeat-Accumulate (RA) codes are the simplest turbo-like codes that achieve good performance. However, they cannot compete with Turbo codes or low-density parity check codes (LDPC) as far as performance is concerned. The Accumulate Repeat Accumulate (ARA) codes, as a subclass of LDPC codes, are obtained by adding a pre-coder in front of RA codes with puncturing where an accumulator is chosen as a precoder. These codes not only are very simple, but also achieve excellent performance with iterative decoding. In this paper, the performance of these codes with (ML) decoding are analyzed and compared to random codes by very tight bounds. The weight distribution of some simple ARA codes is obtained, and through existing tightest bounds we have shown the ML SNR threshold of ARA codes approaches very closely to the performance of random codes. We have shown that the use of precoder improves the SNR threshold but interleaving gain remains unchanged with respect to RA code with puncturing.

  8. Development of Pineapple Microsatellite Markers and Germplasm Genetic Diversity Analysis

    PubMed Central

    Tong, Helin; Chen, You; Wang, Jingyi; Chen, Yeyuan; Sun, Guangming; He, Junhu; Wu, Yaoting

    2013-01-01

    Two methods were used to develop pineapple microsatellite markers. Genomic library-based SSR development: using selectively amplified microsatellite assay, 86 sequences were generated from pineapple genomic library. 91 (96.8%) of the 94 Simple Sequence Repeat (SSR) loci were dinucleotide repeats (39 AC/GT repeats and 52 GA/TC repeats, accounting for 42.9% and 57.1%, resp.), and the other three were mononucleotide repeats. Thirty-six pairs of SSR primers were designed; 24 of them generated clear bands of expected sizes, and 13 of them showed polymorphism. EST-based SSR development: 5659 pineapple EST sequences obtained from NCBI were analyzed; among 1397 nonredundant EST sequences, 843 were found containing 1110 SSR loci (217 of them contained more than one SSR locus). Frequency of SSRs in pineapple EST sequences is 1SSR/3.73 kb, and 44 types were found. Mononucleotide, dinucleotide, and trinucleotide repeats dominate, accounting for 95.6% in total. AG/CT and AGC/GCT were the dominant type of dinucleotide and trinucleotide repeats, accounting for 83.5% and 24.1%, respectively. Thirty pairs of primers were designed for each of randomly selected 30 sequences; 26 of them generated clear and reproducible bands, and 22 of them showed polymorphism. Eighteen pairs of primers obtained by the one or the other of the two methods above that showed polymorphism were selected to carry out germplasm genetic diversity analysis for 48 breeds of pineapple; similarity coefficients of these breeds were between 0.59 and 1.00, and they can be divided into four groups accordingly. Amplification products of five SSR markers were extracted and sequenced, corresponding repeat loci were found and locus mutations are mainly in copy number of repeats and base mutations in the flanking region. PMID:24024187

  9. Rear shape in 3 dimensions summarized by principal component analysis is a good predictor of body condition score in Holstein dairy cows.

    PubMed

    Fischer, A; Luginbühl, T; Delattre, L; Delouard, J M; Faverdin, P

    2015-07-01

    Body condition is an indirect estimation of the level of body reserves, and its variation reflects cumulative variation in energy balance. It interacts with reproductive and health performance, which are important to consider in dairy production but not easy to monitor. The commonly used body condition score (BCS) is time consuming, subjective, and not very sensitive. The aim was therefore to develop and validate a method assessing BCS with 3-dimensional (3D) surfaces of the cow's rear. A camera captured 3D shapes 2 m from the floor in a weigh station at the milking parlor exit. The BCS was scored by 3 experts on the same day as 3D imaging. Four anatomical landmarks had to be identified manually on each 3D surface to define a space centered on the cow's rear. A set of 57 3D surfaces from 56 Holstein dairy cows was selected to cover a large BCS range (from 0.5 to 4.75 on a 0 to 5 scale) to calibrate 3D surfaces on BCS. After performing a principal component analysis on this data set, multiple linear regression was fitted on the coordinates of these surfaces in the principal components' space to assess BCS. The validation was performed on 2 external data sets: one with cows used for calibration, but at a different lactation stage, and one with cows not used for calibration. Additionally, 6 cows were scanned once and their surfaces processed 8 times each for repeatability and then these cows were scanned 8 times each the same day for reproducibility. The selected model showed perfect calibration and a good but weaker validation (root mean square error=0.31 for the data set with cows used for calibration; 0.32 for the data set with cows not used for calibration). Assessing BCS with 3D surfaces was 3 times more repeatable (standard error=0.075 versus 0.210 for BCS) and 2.8 times more reproducible than manually scored BCS (standard error=0.103 versus 0.280 for BCS). The prediction error was similar for both validation data sets, indicating that the method is not less efficient for cows not used for calibration. The major part of reproducibility error incorporates repeatability error. An automation of the anatomical landmarks identification is required, first to allow broadband measures of body condition and second to improve repeatability and consequently reproducibility. Assessing BCS using 3D imaging coupled with principal component analysis appears to be a very promising means of improving precision and feasibility of this trait measurement. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  10. Rapid Detection of Cell-Free Mycobacterium tuberculosis DNA in Tuberculous Pleural Effusion.

    PubMed

    Che, Nanying; Yang, Xinting; Liu, Zichen; Li, Kun; Chen, Xiaoyou

    2017-05-01

    Tuberculous pleurisy is one of the most common types of extrapulmonary tuberculosis, but its diagnosis remains difficult. In this study, we report for the first time on the detection of cell-free Mycobacterium tuberculosis DNA in pleural effusion and an evaluation of a newly developed molecular assay for the detection of cell-free Mycobacterium tuberculosis DNA. A total of 78 patients with pleural effusion, 60 patients with tuberculous pleurisy, and 18 patients with alternative diseases were included in this study. Mycobacterial culture, the Xpert MTB/RIF assay, the adenosine deaminase assay, the T-SPOT.TB assay, and the cell-free Mycobacterium tuberculosis DNA assay were performed on all the pleural effusion samples. The cell-free Mycobacterium tuberculosis DNA assay and adenosine deaminase assay showed significantly higher sensitivities of 75.0% and 68.3%, respectively, than mycobacterial culture and the Xpert MTB/RIF assay, which had sensitivities of 26.7% and 20.0%, respectively ( P < 0.01). All four of these tests showed good specificities: 88.9% for the adenosine deaminase assay and 100% for the remaining three assays. The T-SPOT.TB assay with pleural effusion showed the highest sensitivity of 95.0% but the lowest specificity of 38.9%. The cell-free Mycobacterium tuberculosis DNA assay detected as few as 1.25 copies of IS 6110 per ml of pleural effusion and showed good accordance of the results between repeated tests ( r = 0.978, P = 2.84 × 10 -10 ). These data suggest that the cell-free Mycobacterium tuberculosis DNA assay is a rapid and accurate molecular test which provides direct evidence of Mycobacterium tuberculosis etiology. Copyright © 2017 American Society for Microbiology.

  11. Rapid Detection of Cell-Free Mycobacterium tuberculosis DNA in Tuberculous Pleural Effusion

    PubMed Central

    Yang, Xinting; Liu, Zichen; Li, Kun

    2017-01-01

    ABSTRACT Tuberculous pleurisy is one of the most common types of extrapulmonary tuberculosis, but its diagnosis remains difficult. In this study, we report for the first time on the detection of cell-free Mycobacterium tuberculosis DNA in pleural effusion and an evaluation of a newly developed molecular assay for the detection of cell-free Mycobacterium tuberculosis DNA. A total of 78 patients with pleural effusion, 60 patients with tuberculous pleurisy, and 18 patients with alternative diseases were included in this study. Mycobacterial culture, the Xpert MTB/RIF assay, the adenosine deaminase assay, the T-SPOT.TB assay, and the cell-free Mycobacterium tuberculosis DNA assay were performed on all the pleural effusion samples. The cell-free Mycobacterium tuberculosis DNA assay and adenosine deaminase assay showed significantly higher sensitivities of 75.0% and 68.3%, respectively, than mycobacterial culture and the Xpert MTB/RIF assay, which had sensitivities of 26.7% and 20.0%, respectively (P < 0.01). All four of these tests showed good specificities: 88.9% for the adenosine deaminase assay and 100% for the remaining three assays. The T-SPOT.TB assay with pleural effusion showed the highest sensitivity of 95.0% but the lowest specificity of 38.9%. The cell-free Mycobacterium tuberculosis DNA assay detected as few as 1.25 copies of IS6110 per ml of pleural effusion and showed good accordance of the results between repeated tests (r = 0.978, P = 2.84 × 10−10). These data suggest that the cell-free Mycobacterium tuberculosis DNA assay is a rapid and accurate molecular test which provides direct evidence of Mycobacterium tuberculosis etiology. PMID:28275073

  12. Reliability, stability, and sensitivity to change and impairment in acoustic measures of timing and frequency.

    PubMed

    Vogel, Adam P; Fletcher, Janet; Snyder, Peter J; Fredrickson, Amy; Maruff, Paul

    2011-03-01

    Assessment of the voice for supporting classifications of central nervous system (CNS) impairment requires a different practical, methodological, and statistical framework compared with assessment of the voice to guide decisions about change in the CNS. In experimental terms, an understanding of the stability and sensitivity to change of an assessment protocol is required to guide decisions about CNS change. Five experiments (N = 70) were conducted using a set of commonly used stimuli (eg, sustained vowel, reading, extemporaneous speech) and easily acquired measures (eg, f₀-f₄, percent pause). Stability of these measures was examined through their repeated application in healthy adults over brief and intermediate retest intervals (ie, 30 seconds, 2 hours, and 1 week). Those measures found to be stable were then challenged using an experimental model that reliably changes voice acoustic properties (ie, the Lombard effect). Finally, adults with an established CNS-related motor speech disorder (dysarthria) were compared with healthy controls. Of the 61 acoustic variables studied, 36 showed good stability over all three stability experiments (eg, number of pauses, total speech time, speech rate, f₀-f₄. Of the measures with good stability, a number of frequency measures showed a change in response to increased vocal effort resulting from the Lombard effect challenge. Furthermore, several timing measures significantly separated the control and motor speech impairment groups. Measures with high levels of stability within healthy adults, and those that show sensitivity to change and impairment may prove effective for monitoring changes in CNS functioning. Copyright © 2011 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  13. Service Academy 2006 Gender Relations Survey: Tabulations of Responses

    DTIC Science & Technology

    2006-07-01

    with you without your consent .....56 c. Someone repeatedly showed you pornographic materials, even after you asked him/her not to...harassment, sexual assault, or neither? Assume the behaviors were offensive and harmful to you. c. Someone repeatedly showed you pornographic materials

  14. Role of memory errors in quantum repeaters

    NASA Astrophysics Data System (ADS)

    Hartmann, L.; Kraus, B.; Briegel, H.-J.; Dür, W.

    2007-03-01

    We investigate the influence of memory errors in the quantum repeater scheme for long-range quantum communication. We show that the communication distance is limited in standard operation mode due to memory errors resulting from unavoidable waiting times for classical signals. We show how to overcome these limitations by (i) improving local memory and (ii) introducing two operational modes of the quantum repeater. In both operational modes, the repeater is run blindly, i.e., without waiting for classical signals to arrive. In the first scheme, entanglement purification protocols based on one-way classical communication are used allowing to communicate over arbitrary distances. However, the error thresholds for noise in local control operations are very stringent. The second scheme makes use of entanglement purification protocols with two-way classical communication and inherits the favorable error thresholds of the repeater run in standard mode. One can increase the possible communication distance by an order of magnitude with reasonable overhead in physical resources. We outline the architecture of a quantum repeater that can possibly ensure intercontinental quantum communication.

  15. Highly sensitive copper fiber-in-tube solid-phase microextraction for online selective analysis of polycyclic aromatic hydrocarbons coupled with high performance liquid chromatography.

    PubMed

    Sun, Min; Feng, Juanjuan; Bu, Yanan; Luo, Chuannan

    2015-08-21

    A fiber-in-tube solid-phase microextraction (SPME) device was developed with copper wire and copper tube, which was served as both the substrate and sorbent with high physical strength and good flexibility. Its morphology and surface properties were characterized by scanning electron microscopy and energy dispersive X-ray spectrometry. It was coupled with high performance liquid chromatography (HPLC) equipment by replacing the sample loop of six-port injection valve, building the online SPME-HPLC system conveniently. Using ten polycyclic aromatic hydrocarbons (PAHs) as model analytes, extraction conditions including sampling rate, extraction time, organic content and desorption time were investigated and optimized. The copper fiber-in-tube exhibits excellent extraction efficiency toward PAHs, with enrichment factors from 268 to 2497. The established online SPME-HPLC method provides good linearity (0.05-100μgL(-1)) and low detection limits (0.001-0.01μgL(-1)) for PAHs. It has been used to determine PAHs in water samples, with recoveries in the range of 86.2-115%. Repeatability on the same extraction tube is in the range of 0.6-3.6%, and repeatability among three tubes is in the range of 5.6-20.1%. Compared with phthalates, anilines and phenols, the copper fiber-in-tube possesses good extraction selectivity for PAHs. The extraction mechanism is probably related to hydrophobic interaction and π-electron-metal interaction. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Time lapse (4D) and AVO analysis: A case study of Gullfaks field, Northern North Sea

    NASA Astrophysics Data System (ADS)

    Umoren, Emmanuel Bassey; George, Nyakno Jimmy

    2018-06-01

    A 4D seismic or time lapse survey has been used to investigate the amplitude versus offset (AVO) effects on seismic data in order to identify anomalies in the Gullfaks field for three different reservoir intervals namely the Tarbert, Cook and Statfjord reservoirs. Repeatability analysis has shown that the earlier seismic vintages are the most unreliable for amplitude anomaly analysis as normalised root-mean square (NRMS) values are greater than 50%. This is above the threshold of good and medium repeatability. Fluid substitution models show increases in both P-wave velocity and density for increasing water saturations with a maximum change of 7.33% in the P-wave velocity, and this is in line with predictions from previous work using the Biot - Gassman equations. AVO modelling for the top Tarbert Formation interface produced scenarios of increasing amplitudes with offset for the presence of hydrocarbons, which dim out with 100% brine saturation. This correlates to class III gas sands for different situations of varying Poisson's ratio across an interface, which has been previously modelled. Two anomalies were identified with one being related to increasing pressure due to water injection correlating to poor permeability around injector well 34/10-B-33. The second anomaly is a case of potential unswept hydrocarbons that displayed a consistent bright spot throughout all of the seismic vintages (in-inlines and crosslines). AVO attribute analysis of this event produced a class II anomaly. However, when comparing near and far offset seismic data, dimming effect was observed producing contrasting evidence. The dimming offset is viewed to have been as a result of poor repeatability values at far offsets. The modelling of the fluid contents in the studied formations to conform to existing literatures justifies the efficacy of the method.

  17. Granulocyte colony-stimulating factor in repeated IVF failure, a randomized trial.

    PubMed

    Aleyasin, Ashraf; Abediasl, Zhila; Nazari, Atefeh; Sheikh, Mahdi

    2016-06-01

    Recent studies have revealed key roles for granulocyte colony-stimulating factor (GCSF) in embryo implantation process and maintenance of pregnancy, and some studies showed promising results by using local intrauterine infusion of GCSF in patients undergoing in vitro fertilization (IVF). This multicenter, randomized, controlled trial included 112 infertile women with repeated IVF failure to evaluate the efficacy of systemic single-dose subcutaneous GCSF administration on IVF success in these women. In this study, the Long Protocol of ovarian stimulation was used for all participants. Sealed, numbered envelopes assigned 56 patients to receive subcutaneous 300 µg GCSF before implantation and 56 in the control group. The implantation (number of gestational sacs on the total number of transferred embryos), chemical pregnancy (positive serum β-HCG), and clinical pregnancy (gestational sac and fetal heart) rates were compared between the two groups. This trial is registered at www.irct.ir (IRCT201503119568N11). The successful implantation (18% vs 7.2%, P=0.007), chemical pregnancy (44.6% vs 19.6%, P=0.005), and clinical pregnancy (37.5% vs 14.3%, P=0.005) rates were significantly higher in the intervention group than in the control group. After adjustment for participants' age, endometrial thickness, good-quality oocyte counts, number of transferred embryos, and anti-Mullerian hormone levels, GCSF treatment remained significantly associated with successful implantation (OR=2.63, 95% CI=1.09-6.96), having chemical pregnancy (OR= 2.74, 95% CI=1.11-7.38) and clinical pregnancy (OR=2.94, 95% CI=1.23-8.33). In conclusion, administration of single-dose systemic subcutaneous GCSF before implantation significantly increases the IVF success, implantation, and pregnancy rates in infertile women with repeated IVF failure. © 2016 Society for Reproduction and Fertility.

  18. Too much of a good thing: blocking noradrenergic facilitation in medial prefrontal cortex prevents the detrimental effects of chronic stress on cognition.

    PubMed

    Jett, Julianne D; Morilak, David A

    2013-03-01

    Cognitive impairments associated with dysfunction of the medial prefrontal cortex (mPFC) are prominent in stress-related psychiatric disorders. We have shown that enhancing noradrenergic tone acutely in the rat mPFC facilitated extra-dimensional (ED) set-shifting on the attentional set-shifting test (AST), whereas chronic unpredictable stress (CUS) impaired ED. In this study, we tested the hypothesis that the acute facilitatory effect of norepinephrine (NE) in mPFC becomes detrimental when activated repeatedly during CUS. Using microdialysis, we showed that the release of NE evoked in mPFC by acute stress was unchanged at the end of CUS treatment. Thus, to then determine if repeated elicitation of this NE activity in mPFC during CUS may have contributed to the ED deficit, we infused a cocktail of α(1)-, β(1)-, and β(2)-adrenergic receptor antagonists into the mPFC prior to each CUS session, then tested animals drug free on the AST. Antagonist treatment prevented the CUS-induced ED deficit, suggesting that NE signaling during CUS compromised mPFC function. We confirmed that this was not attributable to sensitization of adrenergic receptor function following chronic antagonist treatment, by administering an additional microinjection into the mPFC immediately prior to ED testing. Acute antagonist treatment did not reverse the beneficial effects of chronic drug treatment during CUS, nor have any effect on baseline ED performance in chronic vehicle controls. Thus, we conclude that blockade of noradrenergic receptors in mPFC protected against the detrimental cognitive effects of CUS, and that repeated elicitation of noradrenergic facilitatory activity is one mechanism by which chronic stress may promote mPFC cognitive dysfunction.

  19. The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children : Part I: repeatability, observer variability and general analysis.

    PubMed

    Padayachy, Llewellyn C; Padayachy, Vaishali; Galal, Ushma; Gray, Rebecca; Fieggen, A Graham

    2016-10-01

    The aim of this study was to investigate the relationship between optic nerve sheath diameter (ONSD) measurement and invasively measured intracranial pressure (ICP) in children. ONSD measurement was performed prior to invasive measurement of ICP. The mean binocular ONSD measurement was compared to the ICP reading. Physiological variables including systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), pulse rate, temperature, respiratory rate and end tidal carbon dioxide (ETCO2) level were recorded at the time of ONSD measurement. Diagnostic accuracy analysis was performed at various ICP thresholds and  repeatability, intra- and inter-observer variability, correlation between measurements in different imaging planes as well the relationship over the entire patient cohort were examined in part I of this study. Data from 174 patients were analysed. Repeatability and intra-observer variability were excellent (α = 0.97-0.99). Testing for inter-observer variability revealed good correlation (r = 0.89, p < 0.001). Imaging in the sagittal plane demonstrated a slightly better correlation with ICP (r = 0.66, p < 0.001). The ONSD measurement with the best diagnostic accuracy for detecting an ICP ≥ 20 mmHg over the entire patient cohort was 5.5 mm, sensitivity 93.2 %, specificity 74 % and odds ratio (OR) of 39.3. Transorbital ultrasound measurement of the OSND is a reliable and reproducible technique, demonstrating a good relationship with ICP and high diagnostic accuracy for detecting raised ICP.

  20. RGO-coated elastic fibres as wearable strain sensors for full-scale detection of human motions

    NASA Astrophysics Data System (ADS)

    Mi, Qing; Wang, Qi; Zang, Siyao; Mao, Guoming; Zhang, Jinnan; Ren, Xiaomin

    2018-01-01

    In this study, we chose highly-elastic fabric fibres as the functional carrier and then simply coated the fibres with reduced graphene oxide (rGO) using plasma treatment, dip coating and hydrothermal reduction steps, finally making a wearable strain sensor. As a result, the full-scale detection of human motions, ranging from bending joints to the pulse beat, has been achieved by these sensors. Moreover, high sensitivity, good stability and excellent repeatability were realized. The good sensing performances and economical fabrication process of this wearable strain sensor have strengthened our confidence in practical applications in smart clothing, smart fabrics, healthcare, and entertainment fields.

  1. A study of the Huntington's disease associated trinucleotide repeat in the Scottish population.

    PubMed Central

    Barron, L H; Warner, J P; Porteous, M; Holloway, S; Simpson, S; Davidson, R; Brock, D J

    1993-01-01

    Accurate measurements of a specific CAG repeat sequence in the Huntington's disease (HD) gene in 337 HD patients and 229 normal controls from the Scottish population showed a range from 35 to 62 repeats in affected subjects and eight to 33 in normal subjects. A link between early onset of symptoms and very high repeat number was seen. For HD patients with the most common affected allele sizes (39 to 42 repeats) absolute repeat size was a poor index for the age at onset of symptoms. There was variability in the transmitted repeat size for both sexes in the HD size range. We observed a significant increase of repeat size for paternal transmission of the disease and greater instability for paternally transmitted CAG repeats in the HD size range. Images PMID:8133495

  2. Patterns and determinants of mammography screening in Lebanese women.

    PubMed

    Elias, Nadia; Bou-Orm, Ibrahim R; Adib, Salim M

    2017-03-01

    The associations of ever using and/or repeating a mammography test with psychosocial and socio-demographic factors were surveyed in 2014 among Lebanese women ≥ 40. A sample of 2400 women was selected across Lebanon. Variables with significant bivariate associations with various types of behaviors were entered in multivariate analysis. Of the total, 105 women (4·4%) had never heard of mammography as a tool for early breast cancer detection. Among the remaining 2295, 45% had ever used it, of whom 10% had obtained it for the first time within the 12 months preceding the survey. Repeaters were 67% of 926 women who had the time opportunity to do so (median lifetime frequency: 2). Older age, higher socio-economic status (SES) and living within the Greater Beirut (GB) area were significantly associated with ever-use. Within GB, psychosocial factors such as perceived susceptibility and benefits were most strongly associated with ever-use. Outside GB, socio-economic advantage seemed to mostly affect ever-use. Only 4% reported opposition from husbands to their mammography, and husband's support was significant for adherence to mammography guidelines mostly outside GB. Higher education emerged also as a significant socio-demographic determinant for ever-repeating in all regions. Perceived comfort of the previous test strongly affected the likelihood of repeating it. Providing mammography free-of-charge may alleviate some obstacles among women with socio-economic disadvantage. Stressing that good results one year do not make the cancer less likely or repeating the test less important, as well as improving the comfort of mammography testing could ensure test repeating.

  3. ACCA phosphopeptide recognition by the BRCT repeats of BRCA1.

    PubMed

    Ray, Hind; Moreau, Karen; Dizin, Eva; Callebaut, Isabelle; Venezia, Nicole Dalla

    2006-06-16

    The tumour suppressor gene BRCA1 encodes a 220 kDa protein that participates in multiple cellular processes. The BRCA1 protein contains a tandem of two BRCT repeats at its carboxy-terminal region. The majority of disease-associated BRCA1 mutations affect this region and provide to the BRCT repeats a central role in the BRCA1 tumour suppressor function. The BRCT repeats have been shown to mediate phospho-dependant protein-protein interactions. They recognize phosphorylated peptides using a recognition groove that spans both BRCT repeats. We previously identified an interaction between the tandem of BRCA1 BRCT repeats and ACCA, which was disrupted by germ line BRCA1 mutations that affect the BRCT repeats. We recently showed that BRCA1 modulates ACCA activity through its phospho-dependent binding to ACCA. To delineate the region of ACCA that is crucial for the regulation of its activity by BRCA1, we searched for potential phosphorylation sites in the ACCA sequence that might be recognized by the BRCA1 BRCT repeats. Using sequence analysis and structure modelling, we proposed the Ser1263 residue as the most favourable candidate among six residues, for recognition by the BRCA1 BRCT repeats. Using experimental approaches, such as GST pull-down assay with Bosc cells, we clearly showed that phosphorylation of only Ser1263 was essential for the interaction of ACCA with the BRCT repeats. We finally demonstrated by immunoprecipitation of ACCA in cells, that the whole BRCA1 protein interacts with ACCA when phosphorylated on Ser1263.

  4. Stability of Tandem Repeats in the Drosophila Melanogaster HSR-Omega Nuclear RNA

    PubMed Central

    Hogan, N. C.; Slot, F.; Traverse, K. L.; Garbe, J. C.; Bendena, W. G.; Pardue, M. L.

    1995-01-01

    The Drosophila melanogaster Hsr-omega locus produces a nuclear RNA containing >5 kb of tandem repeat sequences. These repeats are unique to Hsr-omega and show concerted evolution similar to that seen with classical satellite DNAs. In D. melanogaster the monomer is ~280 bp. Sequences of 191/2 monomers differ by 8 +/- 5% (mean +/- SD), when all pairwise comparisons are considered. Differences are single nucleotide substitutions and 1-3 nucleotide deletions/insertions. Changes appear to be randomly distributed over the repeat unit. Outer repeats do not show the decrease in monomer homogeneity that might be expected if homogeneity is maintained by recombination. However, just outside the last complete repeat at each end, there are a few fragments of sequence similar to the monomer. The sequences in these flanking regions are not those predicted for sequences decaying in the absence of recombination. Instead, the fragmentation of the sequence homology suggests that flanking regions have undergone more severe disruptions, possibly during an insertion or amplification event. Hsr-omega alleles differing in the number of repeats are detected and appear to be stable over a few thousand generations; however, both increases and decreases in repeat numbers have been observed. The new alleles appear to be as stable as their predecessors. No alleles of less than ~5 kb nor more than ~16 kb of repeats were seen in any stocks examined. The evidence that there is a limit on the minimum number of repeats is consistent with the suggestion that these repeats are important in the function of the unusual Hsr-omega nuclear RNA. PMID:7540581

  5. Effective Classification and Gene Expression Profiling for the Facioscapulohumeral Muscular Dystrophy

    PubMed Central

    González-Navarro, Félix F.; Belanche-Muñoz, Lluís A.; Silva-Colón, Karen A.

    2013-01-01

    The Facioscapulohumeral Muscular Dystrophy (FSHD) is an autosomal dominant neuromuscular disorder whose incidence is estimated in about one in 400,000 to one in 20,000. No effective therapeutic strategies are known to halt progression or reverse muscle weakness and atrophy. It is known that the FSHD is caused by modifications located within a D4ZA repeat array in the chromosome 4q, while recent advances have linked these modifications to the DUX4 gene. Unfortunately, the complete mechanisms responsible for the molecular pathogenesis and progressive muscle weakness still remain unknown. Although there are many studies addressing cancer databases from a machine learning perspective, there is no such precedent in the analysis of the FSHD. This study aims to fill this gap by analyzing two specific FSHD databases. A feature selection algorithm is used as the main engine to select genes promoting the highest possible classification capacity. The combination of feature selection and classification aims at obtaining simple models (in terms of very low numbers of genes) capable of good generalization, that may be associated with the disease. We show that the reported method is highly efficient in finding genes to discern between healthy cases (not affected by the FSHD) and FSHD cases, allowing the discovery of very parsimonious models that yield negligible repeated cross-validation error. These models in turn give rise to very simple decision procedures in the form of a decision tree. Current biological evidence regarding these genes shows that they are linked to skeletal muscle processes concerning specific human conditions. PMID:24349187

  6. The effect of giving global coronary risk information to adults: a systematic review.

    PubMed

    Sheridan, Stacey L; Viera, Anthony J; Krantz, Mori J; Ice, Christa L; Steinman, Lesley E; Peters, Karen E; Kopin, Laurie A; Lungelow, Danielle

    2010-02-08

    Global coronary heart disease (CHD) risk estimation (ie, a quantitative estimate of a patient's chances of CHD calculated by combining risk factors in an empirical equation) is recommended as a starting point for primary prevention efforts in all US adults. Whether it improves outcomes is currently unknown. To assess the effect of providing global CHD risk information to adults, we performed a systematic evidence review. We searched MEDLINE for the years 1980 to 2008, Psych Info, CINAHL, and the Cochrane Database and included English-language articles that met prespecified inclusion criteria. Two reviewers independently reviewed titles, abstracts, and articles for inclusion and assessed study quality. We identified 20 articles, reporting on 18 unique fair or good quality studies (including 14 randomized controlled studies). These showed that global CHD risk information alone or with accompanying education increased the accuracy of perceived risk and probably increased intent to start therapy. Studies with repeated risk information or risk information and repeated doses of counseling showed small significant reductions in predicted CHD risk (absolute differences, -0.2% to -2% over 10 years in studies using risk estimates derived from Framingham equations). Studies providing global risk information at only 1 point in time seemed ineffective. Global CHD risk information seems to improve the accuracy of risk perception and may increase intent to initiate CHD prevention among individuals at moderate to high risk. The effect of global risk presentation on more distal outcomes is less clear and seems to be related to the intensity of accompanying interventions.

  7. Stabilization of perfect and imperfect tandem repeats by single-strand DNA exonucleases

    PubMed Central

    Feschenko, Vladimir V.; Rajman, Luis A.; Lovett, Susan T.

    2003-01-01

    Rearrangements between tandemly repeated DNA sequences are a common source of genetic instability. Such rearrangements underlie several human genetic diseases. In many organisms, the mismatch-repair (MMR) system functions to stabilize repeats when the repeat unit is short or when sequence imperfections are present between the repeats. We show here that the action of single-stranded DNA (ssDNA) exonucleases plays an additional, important role in stabilizing tandem repeats, independent of their role in MMR. For perfect repeats of ≈100 bp in Escherichia coli that are not susceptible to MMR, exonuclease (Exo)-I, ExoX, and RecJ exonuclease redundantly inhibit deletion. Our data suggest that >90% of potential deletion events are avoided by the combined action of these three exonucleases. Imperfect tandem repeats, less prone to rearrangements, are stabilized by both the MMR-pathway and ssDNA-specific exonucleases. For 100-bp repeats containing four mispairs, ExoI alone aborts most deletion events, even in the presence of a functional MMR system. By genetic analysis, we show that the inhibitory effect of ssDNA exonucleases on deletion formation is independent of the MutS and UvrD proteins. Exonuclease degradation of DNA displaced during the deletion process may abort slipped misalignment. Exonuclease action is therefore a significant force in genetic stabilization of many forms of repetitive DNA. PMID:12538867

  8. Are There Multiple Populations of Fast Radio Bursts?

    NASA Astrophysics Data System (ADS)

    Palaniswamy, Divya; Li, Ye; Zhang, Bing

    2018-02-01

    The repeating FRB 121102 (the “repeater”) shows repetitive bursting activities and was localized in a host galaxy at z = 0.193. On the other hand, despite dozens of hours of telescope time spent on follow-up observations, no other fast radio bursts (FRBs) have been observed to repeat. Yet, it has been speculated that the repeater is the prototype of FRBs, and that other FRBs should show similar repeating patterns. Using the published data, we compare the repeater with other FRBs in the observed time interval (Δt)–flux ratio (S i /S i+1) plane. We find that whereas other FRBs occupy the upper (large S i /S i+1) and right (large Δt) regions of the plane due to the non-detections of other bursts, some of the repeater bursts fall into the lower left region of the plot (short interval and small flux ratio) excluded by the non-detection data of other FRBs. The trend also exists even if one only selects those bursts detectable by the Parkes radio telescope. If other FRBs were similar to the repeater, our simulations suggest that the probability that none of them have been detected to repeat with the current searches would be ∼(10‑4–10‑3). We suggest that the repeater is not representative of the entire FRB population, and that there is strong evidence of more than one population of FRBs.

  9. Development and fabrication of lithium-doped solar cells

    NASA Technical Reports Server (NTRS)

    Iles, P. A.

    1971-01-01

    The application of contacts and coatings after lithium diffusion provides good electrical output and satisfactory contact adhesion by sintering for short times at temperatures less than the lithium diffusion temperature. High output and repeatability are obtainable from both oxygen-rich and oxygen-lean silicon. These fabrication sequence alterations have led to higher cell output, better appearance, and increased contact strength.

  10. Customer Engagement in a U-Commerce Environment: The Effectiveness of Non-Cash Payment Technologies on Customer Retention and Repeat Purchasing Behavior

    ERIC Educational Resources Information Center

    Ojo, Michael A.

    2017-01-01

    The roadmap towards the commercialization of goods and services has been continually enhanced and modified to accommodate a more digital landscape. Businesses are building more robust websites and point-of-service opportunities that do not require human intervention. In turn, consumer shopping patterns and behaviors have shifted in response to…

  11. Photoacoustics of disperse systems: Below cavitation threshold

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Egerev, Sergey; Ovchinnikov, Oleg

    2012-05-24

    The paper considers photoacoustic (PA) conversion while irradiating suspensions in extra-small volume probes with laser pulses having small fluence values. Only linear and nonlinear thermooptical laser sound generation regimes were observed. Thus, good repeatability of acoustic signal parameters informative about probe content was achieved. The experiment conducted has shown how one can avoid the decrease of particles detection sensitivity for the thermooptical mode.

  12. High-lying intermediate excitations in the nuclear effective interaction with a super-soft-core potential

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goode, P.R.; Barrett, B.R.; Portilho, O.

    1979-02-01

    The earlier calculations of Goode and Barrett are repeated using the super-soft-core potential of Gogny, Pires, and de Tourreil. The particular third-order folded diagram which they calculated now converges in its intermediate-state energy summation, because of the suppression of the strong short-range repulsive effects present in earlier calculations.

  13. It's All Good: Children's Personality Attributions after Repeated Success and Failure in Peer and Computer Interactions

    ERIC Educational Resources Information Center

    Boseovski, Janet J.; Shallwani, Sadaf; Lee, Kang

    2009-01-01

    The present study examined children's use of behavioural outcome information to make personality attributions in social and non-social contexts. One hundred and twenty-eight 3- to 6-year-olds were told about a story actor who engaged in primarily successful or primarily unsuccessful interactions with several different people (social context) or…

  14. Generating Enhanced Natural Environments and Terrain for Interactive Combat Simulations (GENETICS)

    DTIC Science & Technology

    2005-09-01

    split to avoid T-junctions ........................................................................52 Figure 2-23 Longest edge bisection...database. This feature allows trainers the flexibility to use the same terrain repeatedly or use a new one each time, forcing trainees to avoid ...model are favored to create a good surface approximation. Cracks are avoided by projecting primitives and their respective textures onto multiple

  15. Effect of the Reread-Adapt and Answer-Comprehend Intervention on the Reading Achievement of Middle and High School Readers Who Are Deaf

    ERIC Educational Resources Information Center

    Schirmer, Barbara R.; Schaffer, Laura; Therrien, William J.; Schirmer, Todd N.

    2016-01-01

    Two studies were conducted to determine if the Reread-Adapt and Answer-Comprehend (RAAC) repeated reading fluency intervention is effective in improving the reading achievement of deaf middle school and high school students. Participants included six middle school students and eight high school students. We found consistently good comprehension…

  16. Flavonoid detection in hydroethanolic extract of Pouteria torta (Sapotaceae) leaves by HPLC-DAD and the determination of its mutagenic activity.

    PubMed

    Costa, Daryne L M G; Rinaldo, Daniel; Varanda, Eliana A; de Sousa, Juliana F; Nasser, Ana L M; Silva, Ana C Z; Baldoqui, Débora C; Vilegas, Wagner; dos Santos, Lourdes Campaner

    2014-10-01

    It is well known that phytotherapy has grown in popularity in recent years. Because a drug cannot be administered without ensuring its effectiveness and safety, the standardization and regulation of phytotherapeutic drugs are required by the global market and governmental authorities. This article describes a simple and reliable high-performance liquid chromatography-diode array detection analysis method for the simultaneous detection of myricetin-3-O-β-D-galactopyranoside, myricetin-3-O-α-L-arabinopyranoside, and myricetin-3-O-α-L-rhaminopyranoside present in the hydroethanolic extract (ethanol/H2O, 7:3, v/v) of Pouteria torta. The mutagenic activity of the extract was evaluated on Salmonella typhimurium and by an in vivo micronucleus test on the peripheral blood cells of Swiss mice. The linearity, sensitivity, selectivity, repeatability, accuracy, and precision of the assay were evaluated. The analytical curves were linear and exhibited good repeatability (with a deviation of less than 5%) and demonstrated good recovery (within the 83-107% range). The results demonstrate that the hydroethanolic extract exhibited a mutagenic activity in both assays, suggesting caution in the use of this plant in folk medicine.

  17. State of the art and perspectives in the treatment of glioblastoma.

    PubMed

    Grimm, Sean A; Chamberlain, Marc C

    2012-09-01

    Glioblastoma is the most common malignant primary brain tumor. Cures are rare and median survival varies from several to 22 months. Standard treatment for good performance patients consists of maximal safe surgical resection followed by radiotherapy with concurrent temozolomide (TMZ) chemotherapy and six cycles of postradiotherapy TMZ. At recurrence, treatment options include repeat surgery (with or without Gliadel wafer placement), reirradiation or systemic therapy. Most patients with good performance status are treated with cytotoxic chemotherapy or targeted biologic therapy following or in lieu of repeat surgery. Cytotoxic chemotherapy options include nitrosoureas, rechallenge with TMZ, platins, phophoramides and topoisomerase inhibitors, although efficacy is limited. Despite the intense effort of developing biologic agents that target angiogenesis and growth and proliferative pathways, bevacizumab is the only agent that has shown efficacy in clinical trials. It was awarded accelerated approval in the USA after demonstrating an impressive radiographic response in two open-label, prospective Phase II studies. Two randomized, Phase III trials of upfront bevacizumab have completed and may demonstrate survival benefit; however, results are pending at this time. Given the limited treatment options at tumor recurrence, consideration for enrollment on a clinical trial is encouraged.

  18. Flavonoid Detection in Hydroethanolic Extract of Pouteria torta (Sapotaceae) Leaves by HPLC-DAD and the Determination of Its Mutagenic Activity

    PubMed Central

    Costa, Daryne L.M.G.; Rinaldo, Daniel; Varanda, Eliana A.; de Sousa, Juliana F.; Nasser, Ana L.M.; Silva, Ana C.Z.; Baldoqui, Débora C.; Vilegas, Wagner

    2014-01-01

    Abstract It is well known that phytotherapy has grown in popularity in recent years. Because a drug cannot be administered without ensuring its effectiveness and safety, the standardization and regulation of phytotherapeutic drugs are required by the global market and governmental authorities. This article describes a simple and reliable high-performance liquid chromatography–diode array detection analysis method for the simultaneous detection of myricetin-3-O-β-D-galactopyranoside, myricetin-3-O-α-L-arabinopyranoside, and myricetin-3-O-α-L-rhaminopyranoside present in the hydroethanolic extract (ethanol/H2O, 7:3, v/v) of Pouteria torta. The mutagenic activity of the extract was evaluated on Salmonella typhimurium and by an in vivo micronucleus test on the peripheral blood cells of Swiss mice. The linearity, sensitivity, selectivity, repeatability, accuracy, and precision of the assay were evaluated. The analytical curves were linear and exhibited good repeatability (with a deviation of less than 5%) and demonstrated good recovery (within the 83–107% range). The results demonstrate that the hydroethanolic extract exhibited a mutagenic activity in both assays, suggesting caution in the use of this plant in folk medicine. PMID:25055245

  19. [Enhanced Recovery after Surgery from Theory to Practice
What do We Need to Do?

    PubMed

    Che, Guowei; Liu, Lunxu; Zhou, Qinghua

    2017-04-20

    Enhanced recovery after surgery (ERAS) is a paradigm shift in perioperative care, resulting in substantial improvements in clinical outcomes, shorter length of hospital stay and cost savings. But the current ERAS either by application of breadth or depth is not enough, why? The main reason is the lack of "operability, evaluation, repetition" ERAS protocol and suitable for clinical extensive application protocol. How to form the clinical available protocol? Operational mainly refers to the clinical scheme is simple and feasible, and protocol compliance is good; Evaluate refers to the methods used before, during and after are the objective evaluation criteria and plan; Repeatable is clinical scheme repeatability in the process of single or multiple center.

  20. Recent social conditions affect boldness repeatability in individual sticklebacks.

    PubMed

    Jolles, Jolle Wolter; Aaron Taylor, Benjamin; Manica, Andrea

    2016-02-01

    Animal personalities are ubiquitous across the animal kingdom and have been shown both to influence individual behaviour in the social context and to be affected by it. However, little attention has been paid to possible carryover effects of social conditions on personality expression, especially when individuals are alone. Here we investigated how the recent social context affected the boldness and repeatability of three-spined sticklebacks, Gasterosteus aculeatus , during individual assays. We housed fish either solitarily, solitarily part of the time or socially in groups of four, and subjected them twice to a risk-taking task. The social conditions had a large effect on boldness repeatability, with fish housed solitarily before the trials showing much higher behavioural repeatability than fish housed socially, for which repeatability was not significant. Social conditions also had a temporal effect on the boldness of the fish, with only fish housed solitarily taking more risks during the first than the second trial. These results show that recent social conditions can thus affect the short-term repeatability of behaviour and obfuscate the expression of personality even in later contexts when individuals are alone. This finding highlights the need to consider social housing conditions when designing personality studies and emphasizes the important link between animal personality and the social context by showing the potential role of social carryover effects.

  1. Recent social conditions affect boldness repeatability in individual sticklebacks

    PubMed Central

    Jolles, Jolle Wolter; Aaron Taylor, Benjamin; Manica, Andrea

    2016-01-01

    Animal personalities are ubiquitous across the animal kingdom and have been shown both to influence individual behaviour in the social context and to be affected by it. However, little attention has been paid to possible carryover effects of social conditions on personality expression, especially when individuals are alone. Here we investigated how the recent social context affected the boldness and repeatability of three-spined sticklebacks, Gasterosteus aculeatus, during individual assays. We housed fish either solitarily, solitarily part of the time or socially in groups of four, and subjected them twice to a risk-taking task. The social conditions had a large effect on boldness repeatability, with fish housed solitarily before the trials showing much higher behavioural repeatability than fish housed socially, for which repeatability was not significant. Social conditions also had a temporal effect on the boldness of the fish, with only fish housed solitarily taking more risks during the first than the second trial. These results show that recent social conditions can thus affect the short-term repeatability of behaviour and obfuscate the expression of personality even in later contexts when individuals are alone. This finding highlights the need to consider social housing conditions when designing personality studies and emphasizes the important link between animal personality and the social context by showing the potential role of social carryover effects. PMID:26949265

  2. Trace determination of volatile polycyclic aromatic hydrocarbons in natural waters by magnetic ionic liquid-based stir bar dispersive liquid microextraction.

    PubMed

    Benedé, Juan L; Anderson, Jared L; Chisvert, Alberto

    2018-01-01

    In this work, a novel hybrid approach called stir bar dispersive liquid microextraction (SBDLME) that combines the advantages of stir bar sorptive extraction (SBSE) and dispersive liquid-liquid microextraction (DLLME) has been employed for the accurate and sensitive determination of ten polycyclic aromatic hydrocarbons (PAHs) in natural water samples. The extraction is carried out using a neodymium stir bar magnetically coated with a magnetic ionic liquid (MIL) as extraction device, in such a way that the MIL is dispersed into the solution at high stirring rates. Once the stirring is ceased, the MIL is magnetically retrieved onto the stir bar, and subsequently subjected to thermal desorption (TD) coupled to a gas chromatography-mass spectrometry (GC-MS) system. The main parameters involved in TD, as well as in the extraction step affecting the extraction efficiency (i.e., MIL amount, extraction time and ionic strength) were evaluated. Under the optimized conditions, the method was successfully validated showing good linearity, limits of detection and quantification in the low ng L -1 level, good intra- and inter-day repeatability (RSD < 13%) and good enrichment factors (18 - 717). This sensitive analytical method was applied to the determination of trace amounts of PAHs in three natural water samples (river, tap and rainwater) with satisfactory relative recovery values (84-115%), highlighting that the matrices under consideration do not affect the extraction process. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Functional recovery upon human dental pulp stem cell transplantation in a diabetic neuropathy rat model.

    PubMed

    Datta, Indrani; Bhadri, Naini; Shahani, Pradnya; Majumdar, Debanjana; Sowmithra, Sowmithra; Razdan, Rema; Bhonde, Ramesh

    2017-10-01

    Diabetic neuropathy (DN) is among the most debilitating complications of diabetes. Here, we investigated the effects of human dental pulp stem cell (DPSC) transplantation in Streptozotocin (STZ)-induced neuropathic rats. Six weeks after STZ injection, DPSCs were transplanted through two routes, intravenous (IV) or intramuscular (IM), in single or two repeat doses. Two weeks after transplantation, a significant improvement in hyperalgesia, grip-strength, motor coordination and nerve conduction velocity was observed in comparison with controls. A rapid improvement in neuropathic symptoms was observed for a single dose of DPSC IV; however, repeat dose of DPSC IV did not bring about added improvement. A single dose of DPSC IM showed steady improvement, and further recovery continued upon repeat IM administration. DPSC single dose IV showed greater improvement than DPSC single dose IM, but IM transplantation brought about better improvement in body weight. A marked reduction in tumor necrosis factor (TNF) α and C-reactive protein (CRP) levels was observed in the blood plasma for all treated groups, as compared with controls. With respect to inflammatory cytokines, repeat dose of DPSC IM showed further improvement, suggesting that a repeat dose is required to maintain the improved inflammatory state. Gene expression of inflammatory markers in liver confirmed amelioration in inflammation. Arachidonic acid level was unaffected by IV DPSC transplantation but showed noticeable increase through IM administration of a repeat dose. These results suggest that DPSC transplantation through both routes and dosage was beneficial for the retrieval of neuropathic parameters of DN; transplantation via the IM route with repeat dose was the most effective. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  4. Upstream mononucleotide A-repeats play a cis-regulatory role in mammals through the DICER1 and Ago proteins.

    PubMed

    Aporntewan, Chatchawit; Pin-on, Piyapat; Chaiyaratana, Nachol; Pongpanich, Monnat; Boonyaratanakornkit, Viroj; Mutirangura, Apiwat

    2013-10-01

    A-repeats are the simplest form of tandem repeats and are found ubiquitously throughout genomes. These mononucleotide repeats have been widely believed to be non-functional 'junk' DNA. However, studies in yeasts suggest that A-repeats play crucial biological functions, and their role in humans remains largely unknown. Here, we showed a non-random pattern of distribution of sense A- and T-repeats within 20 kb around transcription start sites (TSSs) in the human genome. Different distributions of these repeats are observed upstream and downstream of TSSs. Sense A-repeats are enriched upstream, whereas sense T-repeats are enriched downstream of TSSs. This enrichment directly correlates with repeat size. Genes with different functions contain different lengths of repeats. In humans, tissue-specific genes are enriched for short repeats of <10 bp, whereas housekeeping genes are enriched for long repeats of ≥10 bp. We demonstrated that DICER1 and Argonaute proteins are required for the cis-regulatory role of A-repeats. Moreover, in the presence of a synthetic polymer that mimics an A-repeat, protein binding to A-repeats was blocked, resulting in a dramatic change in the expression of genes containing upstream A-repeats. Our findings suggest a length-dependent cis-regulatory function of A-repeats and that Argonaute proteins serve as trans-acting factors, binding to A-repeats.

  5. Tissue- and age-specific DNA replication patterns at the CTG/CAG-expanded human myotonic dystrophy type 1 locus.

    PubMed

    Cleary, John D; Tomé, Stéphanie; López Castel, Arturo; Panigrahi, Gagan B; Foiry, Laurent; Hagerman, Katharine A; Sroka, Hana; Chitayat, David; Gourdon, Geneviève; Pearson, Christopher E

    2010-09-01

    Myotonic dystrophy, caused by DM1 CTG/CAG repeat expansions, shows varying instability levels between tissues and across ages within patients. We determined DNA replication profiles at the DM1 locus in patient fibroblasts and tissues from DM1 transgenic mice of various ages showing different instability. In patient cells, the repeat is flanked by two replication origins demarcated by CTCF sites, with replication diminished at the expansion. In mice, the expansion replicated from only the downstream origin (CAG as lagging template). In testes from mice of three different ages, replication toward the repeat paused at the earliest age and was relieved at later ages-coinciding with increased instability. Brain, pancreas and thymus replication varied with CpG methylation at DM1 CTCF sites. CTCF sites between progressing forks and repeats reduced replication depending on chromatin. Thus, varying replication progression may affect tissue- and age-specific repeat instability.

  6. What Is a Good Skeptic to Do? The Case for Skepticism in the Media Violence Discussion.

    PubMed

    Gentile, Douglas A

    2015-09-01

    The discussion about violent video games tends to engender extreme positions, each of which are deserving of deep skepticism. Ferguson's (2015, this issue) claim that humans can do something repeatedly with no effect on them should be examined carefully, especially as it violates most established psychological and learning theories. In this commentary, we examine three aspects of Ferguson's claim. First, it is a typical rhetorical trick to sow doubt, but it is valuable to examine the doubting claims. Second, it is good rhetoric to direct attention in only one direction, but it is valuable to examine that direction within its broader outlook. Third, it is good rhetoric to imply bias on the part of one position, but it is valuable to examine the potential biases on all sides. Good science definitely requires skeptics. The problem with the violent video game debate is perhaps that we have not been skeptical enough. © The Author(s) 2015.

  7. Sustainable cooperation based on reputation and habituation in the public goods game.

    PubMed

    Liu, Yan; Chen, Tong

    2017-10-01

    Reputation can promote cooperation in public goods game and player's cooperative behavior is not pure economical rationality, but habituation would influence their behaviors as well. One's habituation can be formed by repeated behaviors in daily life and be affected by habitual preference. We aim to investigate the sustainable cooperation based on reputation and habit formation. To better investigate the impacts of reputation and habitual preference on the evolution and sustainability of cooperation. We introduce three types of agents into our spatial public goods game. Through numerical simulations, we find that the larger habitual preference make cooperation easier to emerge and maintain. Additionally, we find that a moderate number of agents who want to obtain more reputation (ICs) are best for the sustainability of cooperation. Finally, we observe that the variation of donations of ICs can influence greatly on the equilibrium of public goods game. When ICs reduce their donations, a proper contribution will be better to maintain the cooperative behaviors. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. The Repeated Name Penalty, the Overt Pronoun Penalty, and Topic in Japanese.

    PubMed

    Shoji, Shinichi; Dubinsky, Stanley; Almor, Amit

    2017-02-01

    When reading sentences with an anaphoric reference to a subject antecedent, repeated-name anaphors result in slower reading times relative to pronouns (the Repeated Name Penalty: RNP), and overt pronouns are read slower than null pronouns (the Overt Pronoun Penalty: OPP). Because in most languages previously tested, the grammatical subject is typically also the discourse topic it remains unclear whether these effects reflect anaphors' subject-hood or their topic-hood. To address this question we conducted a self-paced reading experiment in Japanese, a language which morphologically marks both subjects and topics overtly. Our results show that both repeated-name topic-subject anaphors and repeated-name non-topic-subject anaphors exhibit the RNP and that both overt-pronoun topic-subject and overt-pronoun non-topic-subject anaphors show the OPP. However, a detailed examination of performance revealed an interaction between the anaphor topic marking, reference form, and the antecedent's grammatical status, indicating that the effect of the antecedent's grammatical status is strongest for null pronoun and repeated name subject anaphors and that the overt form most similar to null pronouns is the repeated name topic anaphor. We discuss the implications of these findings for theories of anaphor processing.

  9. Repeatability of quantitative 18F-FLT uptake measurements in solid tumors: an individual patient data multi-center meta-analysis.

    PubMed

    Kramer, G M; Liu, Y; de Langen, A J; Jansma, E P; Trigonis, I; Asselin, M-C; Jackson, A; Kenny, L; Aboagye, E O; Hoekstra, O S; Boellaard, R

    2018-06-01

    3'-deoxy-3'-[ 18 F]fluorothymidine ( 18 F-FLT) positron emission tomography (PET) provides a non-invasive method to assess cellular proliferation and response to antitumor therapy. Quantitative 18 F-FLT uptake metrics are being used for evaluation of proliferative response in investigational setting, however multi-center repeatability needs to be established. The aim of this study was to determine the repeatability of 18 F-FLT tumor uptake metrics by re-analyzing individual patient data from previously published reports using the same tumor segmentation method and repeatability metrics across cohorts. A systematic search in PubMed, EMBASE.com and the Cochrane Library from inception-October 2016 yielded five 18 F-FLT repeatability cohorts in solid tumors. 18 F-FLT avid lesions were delineated using a 50% isocontour adapted for local background on test and retest scans. SUV max , SUV mean , SUV peak , proliferative volume and total lesion uptake (TLU) were calculated. Repeatability was assessed using the repeatability coefficient (RC = 1.96 × SD of test-retest differences), linear regression analysis, and the intra-class correlation coefficient (ICC). The impact of different lesion selection criteria was also evaluated. Images from four cohorts containing 30 patients with 52 lesions were obtained and analyzed (ten in breast cancer, nine in head and neck squamous cell carcinoma, and 33 in non-small cell lung cancer patients). A good correlation was found between test-retest data for all 18 F-FLT uptake metrics (R 2  ≥ 0.93; ICC ≥ 0.96). Best repeatability was found for SUV peak (RC: 23.1%), without significant differences in RC between different SUV metrics. Repeatability of proliferative volume (RC: 36.0%) and TLU (RC: 36.4%) was worse than SUV. Lesion selection methods based on SUV max  ≥ 4.0 improved the repeatability of volumetric metrics (RC: 26-28%), but did not affect the repeatability of SUV metrics. In multi-center studies, differences ≥ 25% in 18 F-FLT SUV metrics likely represent a true change in tumor uptake. Larger differences are required for FLT metrics comprising volume estimates when no lesion selection criteria are applied.

  10. StaRProtein, A Web Server for Prediction of the Stability of Repeat Proteins

    PubMed Central

    Xu, Yongtao; Zhou, Xu; Huang, Meilan

    2015-01-01

    Repeat proteins have become increasingly important due to their capability to bind to almost any proteins and the potential as alternative therapy to monoclonal antibodies. In the past decade repeat proteins have been designed to mediate specific protein-protein interactions. The tetratricopeptide and ankyrin repeat proteins are two classes of helical repeat proteins that form different binding pockets to accommodate various partners. It is important to understand the factors that define folding and stability of repeat proteins in order to prioritize the most stable designed repeat proteins to further explore their potential binding affinities. Here we developed distance-dependant statistical potentials using two classes of alpha-helical repeat proteins, tetratricopeptide and ankyrin repeat proteins respectively, and evaluated their efficiency in predicting the stability of repeat proteins. We demonstrated that the repeat-specific statistical potentials based on these two classes of repeat proteins showed paramount accuracy compared with non-specific statistical potentials in: 1) discriminate correct vs. incorrect models 2) rank the stability of designed repeat proteins. In particular, the statistical scores correlate closely with the equilibrium unfolding free energies of repeat proteins and therefore would serve as a novel tool in quickly prioritizing the designed repeat proteins with high stability. StaRProtein web server was developed for predicting the stability of repeat proteins. PMID:25807112

  11. Testing of nylon 6 nanofibers with different surface densities as sorbents for solid phase extraction and their selectivity comparison with commercial sorbent.

    PubMed

    Háková, Martina; Raabová, Hedvika; Havlíková, Lucie Chocholoušová; Chocholouš, Petr; Chvojka, Jiří; Šatínský, Dalibor

    2018-05-01

    Nylon 6 nanofibers were tested for their ability to serve as a sorbent for solid phase extraction (SPE). The regular nanostructure providing a great sorption area and amidic functionality should lead to the assumption that nylon 6 nanofibers could be used as a novel sorbent with great potential for sample pre-treatment. However, due to the substantial differences between classical particle sorbents used for solid phase extraction and nanofibers, it is necessary to evaluate this novel approach. This article describes three types of laboratory fabricated nylon 6 nanofibers with different surface density (5.04gm -2 , 3.90gm -2 and 0.75gm -2 ) and corresponding surface areas for solid phase extraction of several groups of compounds with different structural and physicochemical properties (parabens, steroids, flavonoids and pesticides). The nanofibers were created by needleless electrospinning. Extraction columns were manually packed in classic 1- or 3-mL plastic syringe cartridges with 26-30mg of nanofibers and the column bed was sealed with polypropylene frits. The SPE procedure followed a typical five-step protocol and the collected eluates were analyzed by HPLC with UV detection. Extraction recovery was used as a parameter to evaluate the behavior of the analytes within the SPE process. Under this set condition, the recovery of the SPE process ranged from 23.1% to 125.8%. SPE showed good repeatability (0.58-11.87% RSD) and inter-day reproducibility (3.86-9.79% RSD). The achieved results were compared with SPE using a classic particle sorbent column. Good mechanical and chemical stability of nanofibers was proved. Scanning electron microscope was used for the evaluation of morphological changes in nanostructure. Nylon 6 nanofibers proved being a cost-effective sorbent for repeated use in SPE. Nylon 6 nanofibers have great potential in miniaturized SPE enabling users to overcome troubles with high back-pressure. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Arthrofibrosis involving the middle facet of the talocalcaneal joint in children and adolescents.

    PubMed

    El Rassi, George; Riddle, Eric C; Kumar, S Jay

    2005-10-01

    Pain over the anterolateral aspect of the ankle in a patient with a history of repeated ankle sprains and with restricted subtalar movement may be associated with a tarsal coalition. Nineteen patients presented with such a history, but conventional imaging did not reveal a cartilaginous or osseous coalition. Since symptoms persisted despite nonoperative treatment, the middle facet was explored surgically. The purpose of this study was to discuss the operative findings and to report the results of treatment. Nineteen patients (twenty-three feet) with pain over the anterolateral aspect of the ankle or a history of repeated ankle sprains had restricted subtalar joint motion and inconclusive findings on diagnostic imaging, except for bone-scanning. Their ages ranged from 9.1 to 18.5 years. The middle facet of the subtalar joint was explored surgically through a 3 to 4-cm-long incision centered over the sustentaculum tali. The results at a mean of 5.8 years were classified as good, fair, or poor on the basis of pain, talocalcaneal joint motion, and shoe wear. Routine radiographs, computed tomography, and magnetic resonance imaging revealed no major abnormality, whereas technetium-99m bone scintigraphy consistently showed slightly increased isotope uptake in the middle facet. Surgical removal of a hypervascular and thickened capsule and synovium in the area of the middle facet of the subtalar joint decreased pain and improved subtalar motion. The final result was good in seventeen patients (twenty feet) and fair in two patients (three feet). There were no poor results. A diagnosis of inflammatory arthrofibrosis should be considered when a patient with a painful rigid flatfoot has normal findings on radiographs and hematological studies but increased isotope uptake in the middle facet of the talocalcaneal joint on bone scintigraphy. Excision of the hypervascular capsule and synovium from this area can result in resolution of the symptoms. Therapeutic Level IV.

  13. Effects of an In-season Plyometric Training Program on Repeated Change of Direction and Sprint Performance in the Junior Soccer Player.

    PubMed

    Hammami, Mehréz; Negra, Yassine; Aouadi, Ridha; Shephard, Roy J; Chelly, Mohamed Souhaiel

    2016-12-01

    Hammami, M, Negra, Y, Aouadi, R, Shephard, RJ, and Chelly, MS. Effects of an in-season plyometric training program on repeated change of direction and sprint performance in the junior soccer player. J Strength Cond Res 30(12): 3312-3320, 2016-We aimed to determine the gains in explosive movements of male junior soccer players induced by incorporating an 8-week plyometric training program (PTP) into a standard soccer conditioning regimen 5 months after the beginning of the competitive season. Our hypothesis was that PTP would enhance explosive movements, and thus sprint running, repeated shuttle sprint ability (RSSA), agility and the ability to make repeated changes of direction (RCOD). A group of junior soccer players were randomly divided into 2 groups: an experimental group (E, n = 15, age 15.7 ± 0.2 years) and a control group (C, n = 13, age 15.8 ± 0.2 years). The participants in E and C performed training exercises and matches together, but for an 8-week period in the latter part of the season, the experimental group replaced a part of the normal regimen (the tactical session) by a biweekly course of PTP (hurdle and drop jumps). Two familiarization sessions were held 2 weeks before definitive testing. The ability of the players was assessed by 3 agility tests (a sprint test with 180° turns, a 9-3-6-3-9 m sprint with backward and forward running, and a four 5-m sprint test with turns); 2 repeated sprint tests (RSSA and RCOD); and running times over 5-, 10-, 20-, 30-, and 40-m distances. Participants in E showed gains relative to C in sprint times (p ≤ 0.05 for 5, 10, and 20 m), and 2 of 3 the RCOD parameters (RCOD best, p ≤ 0.001; RCOD total, p ≤ 0.05). However, with the pattern of plyometric training that we adopted, and perhaps because participants were in good initial physical condition, the agility and RSSA test scores remained unchanged. Nevertheless, we conclude that our PTP can be commended to junior soccer players as a means of improving important components of their physical performance.

  14. Repeatability and comparison of clinical techniques for anterior chamber angle assessment.

    PubMed

    Campbell, Peter; Redmond, Tony; Agarwal, Rishi; Marshall, Lewis R; Evans, Bruce J W

    2015-03-01

    To assess the repeatability of gonioscopy, van Herick method and anterior segment Optical Coherence Tomography (AS-OCT) and determine the agreement between these techniques within a community optometry setting. Gonioscopy, van Herick method and AS-OCT imaging were performed by an optometrist on two occasions, 1 month apart, on 80 subjects aged over 40 years recruited from community optometry practices. Anterior segment images were captured with a spectral domain OCT (Topcon 3D OCT-2000; wavelength 840 nm) set to the Anterior Segment (AS) mode. Eyes were graded as open or occludable for each method. AS-OCT images from both visits were graded by a second optometrist masked to the gonioscopy and van Herick method results, and the visit on which the images were acquired. Cohen's kappa (κ) was used to describe the intra-observer repeatability. Likelihood ratios, sensitivity and specificity of van Herick method and AS-OCT were calculated, using gonioscopy as the reference standard. Measurements were obtained from 80 eyes of 80 subjects. In four cases, AS-OCT images were un-gradable due to difficulty in locating the scleral spur. The repeatability of gonioscopy was fair κ = 0.29, while that of the van Herick method (κ = 0.54) and AS-OCT (κ = 0.47) were somewhat better. The van Herick method showed good sensitivity (visit 1: 75%, visit 2: 69%) and high specificity (visit 1: 88%, visit 2: 96%). The sensitivity of AS-OCT was fair (visit 1: 46%, visit 2: 25%), but specificity was high (visit 1: 87%. visit 2: 89%). Intra-observer repeatability was better for van Herick method and for AS-OCT than for gonioscopy, despite the latter being considered the gold standard method. The van Herick method appeared to be more sensitive than AS-OCT when identifying eyes at risk of angle closure. A standalone anterior segment OCT with a longer wavelength laser could afford better visualisation of the angle, and might therefore be expected to enable the examiner to make more precise classifications. These instruments are not widely used by optometrists in clinical practice in the UK at present. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.

  15. Dual pathology as a cause of proteinuria in the post-transplant period; report of a case.

    PubMed

    Tewari, Rohit; Mendonca, Satish; Nijhawan, Vijay

    2016-01-01

    Proteinuria is common after renal transplantation and affects between 35%-45% of patients during the same year as their transplant. We report a case of dual pathology in the renal allograft as a cause of severe proteinuria. A 38-year-old male presented with end-stage renal disease. He underwent live related renal allograft transplant. His immediate post-transplant period was unremarkable. He developed rise in serum creatinine (2.1 mg/dl) 6 months after transplant and was biopsied. He was diagnosed as a case of acute cellular rejection type Ib with suspicion for antibody mediated rejection. He was treated with methylprednisolone to which he showed a good response with return of serum creatinine to 1.6 mg/dl. Subsequently, he developed a nephrotic range proteinuria 6 months after this episode of rejection. Repeat biopsy was performed. He was diagnosed as a case of immune complex mediated glomerulonephritis (GN) (morphologically consistent with pattern of membranoproliferative glomerulonephritis) with chronic humoral rejection in the form of transplant glomerulopathy (TG). IHC for C4d and immunofluorescence studies were instrumental making the diagnosis. He was treated with steroids and rituximab to which he showed a good response with remission of proteinuria. This case highlights the importance of picking up dual pathology in an allograft biopsy to ensure appropriate therapy. The role of C4d and its correct interpretation is further highlighted, especially with regard to pattern (granular versus linear) and location (glomerular capillaries versus peritubular capillaries).

  16. Dual pathology as a cause of proteinuria in the post-transplant period; report of a case

    PubMed Central

    Tewari, Rohit; Mendonca, Satish; Nijhawan, Vijay

    2016-01-01

    Proteinuria is common after renal transplantation and affects between 35%-45% of patients during the same year as their transplant. We report a case of dual pathology in the renal allograft as a cause of severe proteinuria. A 38-year-old male presented with end-stage renal disease. He underwent live related renal allograft transplant. His immediate post-transplant period was unremarkable. He developed rise in serum creatinine (2.1 mg/dl) 6 months after transplant and was biopsied. He was diagnosed as a case of acute cellular rejection type Ib with suspicion for antibody mediated rejection. He was treated with methylprednisolone to which he showed a good response with return of serum creatinine to 1.6 mg/dl. Subsequently, he developed a nephrotic range proteinuria 6 months after this episode of rejection. Repeat biopsy was performed. He was diagnosed as a case of immune complex mediated glomerulonephritis (GN) (morphologically consistent with pattern of membranoproliferative glomerulonephritis) with chronic humoral rejection in the form of transplant glomerulopathy (TG). IHC for C4d and immunofluorescence studies were instrumental making the diagnosis. He was treated with steroids and rituximab to which he showed a good response with remission of proteinuria. This case highlights the importance of picking up dual pathology in an allograft biopsy to ensure appropriate therapy. The role of C4d and its correct interpretation is further highlighted, especially with regard to pattern (granular versus linear) and location (glomerular capillaries versus peritubular capillaries). PMID:28197503

  17. Simultaneous determination of five characteristic stilbene glycosides in root bark of Morus albus L. (Cortex Mori) using high-performance liquid chromatography.

    PubMed

    Piao, Shu-juan; Chen, Li-xia; Kang, Ning; Qiu, Feng

    2011-01-01

    Cortex Mori, one of the well-known traditional Chinese herbal medicines, is derived from the root bark of Morus alba L. according to the China Pharmacopeia. Stilbene glycosides are the main components isolated from aqueous extracts of Morus alba and their content varies depending on where Cortex Mori was collected. We have established a qualitative and quantitative method based on the bioactive stilbene glycosides for control of the quality of Cortex Mori from different sources. To develop a high-performance liquid chromatography coupled with ultraviolet absorption detection for simultaneous quantitative determination of five major characteristic stilbene glycosides in 34 samples of the root bark of Morus alba L. (Cortex Mori) from different sources. The analysis was performed on an ODS column using methanol-water-acetic acid (18: 82: 0.1, v/v/v) as the mobile phase and the peaks were monitored at 320 nm. All calibration curves showed good linearity (r ≥ 0.9991) within test ranges. This method showed good repeatability for the quantification of these five components in Cortex Mori with intra- and inter-day standard deviations less than 2.19% and 1.45%, respectively. The validated method was successfully applied to quantify the five investigated components, including a pair of cis-trans-isomers 1 and 2 and a pair of isomers 4 and 5 in 34 samples of Cortex Mori from different sources. Copyright © 2010 John Wiley & Sons, Ltd.

  18. Stability indicating high performance thin-layer chromatographic method for simultaneous estimation of pantoprazole sodium and itopride hydrochloride in combined dosage form

    PubMed Central

    Bageshwar, Deepak; Khanvilkar, Vineeta; Kadam, Vilasrao

    2011-01-01

    A specific, precise and stability indicating high-performance thin-layer chromatographic method for simultaneous estimation of pantoprazole sodium and itopride hydrochloride in pharmaceutical formulations was developed and validated. The method employed TLC aluminium plates precoated with silica gel 60F254 as the stationary phase. The solvent system consisted of methanol:water:ammonium acetate; 4.0:1.0:0.5 (v/v/v). This system was found to give compact and dense spots for both itopride hydrochloride (Rf value of 0.55±0.02) and pantoprazole sodium (Rf value of 0.85±0.04). Densitometric analysis of both drugs was carried out in the reflectance–absorbance mode at 289 nm. The linear regression analysis data for the calibration plots showed a good linear relationship with R2=0.9988±0.0012 in the concentration range of 100–400 ng for pantoprazole sodium. Also, the linear regression analysis data for the calibration plots showed a good linear relationship with R2=0.9990±0.0008 in the concentration range of 200–1200 ng for itopride hydrochloride. The method was validated for specificity, precision, robustness and recovery. Statistical analysis proves that the method is repeatable and selective for the estimation of both the said drugs. As the method could effectively separate the drug from its degradation products, it can be employed as a stability indicating method. PMID:29403710

  19. Stability indicating high performance thin-layer chromatographic method for simultaneous estimation of pantoprazole sodium and itopride hydrochloride in combined dosage form.

    PubMed

    Bageshwar, Deepak; Khanvilkar, Vineeta; Kadam, Vilasrao

    2011-11-01

    A specific, precise and stability indicating high-performance thin-layer chromatographic method for simultaneous estimation of pantoprazole sodium and itopride hydrochloride in pharmaceutical formulations was developed and validated. The method employed TLC aluminium plates precoated with silica gel 60F 254 as the stationary phase. The solvent system consisted of methanol:water:ammonium acetate; 4.0:1.0:0.5 (v/v/v). This system was found to give compact and dense spots for both itopride hydrochloride ( R f value of 0.55±0.02) and pantoprazole sodium ( R f value of 0.85±0.04). Densitometric analysis of both drugs was carried out in the reflectance-absorbance mode at 289 nm. The linear regression analysis data for the calibration plots showed a good linear relationship with R 2 =0.9988±0.0012 in the concentration range of 100-400 ng for pantoprazole sodium. Also, the linear regression analysis data for the calibration plots showed a good linear relationship with R 2 =0.9990±0.0008 in the concentration range of 200-1200 ng for itopride hydrochloride. The method was validated for specificity, precision, robustness and recovery. Statistical analysis proves that the method is repeatable and selective for the estimation of both the said drugs. As the method could effectively separate the drug from its degradation products, it can be employed as a stability indicating method.

  20. Analysis of beer volatiles by polymeric imidazolium-solid phase microextraction coatings: Synthesis and characterization of polymeric imidazolium ionic liquids.

    PubMed

    González-Álvarez, Jaime; Blanco-Gomis, Domingo; Arias-Abrodo, Pilar; Pello-Palma, Jairo; Ríos-Lombardía, Nicolás; Busto, Eduardo; Gotor-Fernández, Vicente; Gutiérrez-Álvarez, María Dolores

    2013-08-30

    Two polymeric ionic liquids, 3-(but-3″-en-1″-yl)-1-[2'-hydroxycyclohexyl]-1H-imidazol-3-ium bis(trifluoromethanesulfonyl)imide (IL-1) and 1-(2'-hydroxycyclohexyl)-3-(4″-vinylbenzyl)-1H-imidazol-3-ium bis(trifluoromethylsulfonyl)imide (IL-2), have been synthesized by a free radical polymerization reaction and used as coatings for solid-phase microextraction (SPME). These new fibers exhibit good film stability, high thermal stability (270-290°C) and long lifetimes, and are used for the extraction of volatile compounds in lemon beer using gas chromatography separation and flame ionization detection. The scanning electron micrographs of the fiber surface revealed a polymeric ionic liquid (PIL) film, which is distributed homogeneously on the fiber. The developed PIL fiber showed good linearity between 50 and 2000μg/L with regression coefficients in the range of 0.996-0.999. The relative standard deviations (RSD) obtained in the peak area were found to vary between 1% and 12%, which assured that adequate repeatability was achieved. The spiked recoveries for three beer samples ranged from 78.4% to 123.6%. Experimental design has been employed in the optimization of extraction factors and robustness assessment. The polymeric IL-1 butenyl fiber showed a greater efficiency compared to the PDMS-DVB (65μm) and CAR-PDMS (75μm) for the extraction of all of the analytes studied. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

Top