Sample records for shunt function test

  1. Parent ratings of executive functioning in children with shunted hydrocephalus.

    PubMed

    Lacy, Maureen; Baldassarre, Megan; Nader, Todd; Frim, David

    2012-01-01

    The present study examined the executive functioning of a group of children with a history of communicating hydrocephalus and how their level of functioning was correlated with parent ratings of executive functioning. The study examined the executive functioning of 39 shunted children with a history of hydrocephalus and 20 healthy peers. Additionally, parents of both groups of children completed the Behavior Rating Inventory of Executive Function (BRIEF) to assess the parents' perceptions of their children's executive functioning. Finally, the study investigated the relationship between the shunted hydrocephalus children's executive functioning and the parent ratings of their executive functioning. Overall, the children with a history of shunted hydrocephalus displayed more executive dysfunction than their healthy peers. These children were rated by their parents as having more executive dysfunction than their healthy peers and displaying working memory, initiation, mental flexibility and self-monitoring difficulties, which appear to increase with age among the shunted hydrocephalus group. While parent ratings as measured by the BRIEF indices did not correlate with all executive tasks within the shunted hydrocephalus group, the cognitive tests assessing mental flexibility may be sensitive to the problems noted by parents at home. The children with a history of shunted hydrocephalus displayed executive functioning deficits on formal examination. The parents of children with a history of shunted hydrocephalus report ongoing executive difficulties which may increase with age. Copyright © 2012 S. Karger AG, Basel.

  2. Cognitive changes after cerebrospinal fluid shunting in young adults with spina bifida and assumed arrested hydrocephalus

    PubMed Central

    Mataro, M.; Poca, M. A.; Sahuquillo, J.; Cuxart, A.; Iborra, J.; de la Calzada, M. D.; Junque, C.

    2000-01-01

    OBJECTIVES—To establish whether surgery can improve the neuropsychological functioning of young adult patients with spina bifida and apparent clinically arrested hydrocephalus showing abnormal intracranial pressure.
METHODS—Twenty three young adults with spina bifida and assumed arrested hydrocephalus (diagnosed as active or compensated by continuous intracranial pressure monitoring) underwent surgery. All patients received neuropsychological examination before surgery and 6 months later. Neuropsychological assessment included tests of verbal and visual memory, visuospatial functions, speed of mental processing, and frontal lobe functions.
RESULTS—Shunt placement in this subgroup of patients improves neuropsychological functioning, especially in verbal and visual memory and attention and cognitive flexibility.
CONCLUSIONS—Young adults with spina bifida and suspected non-functioning shunt or non-shunted ventriculomegaly should be carefully monitored to identify those who could benefit from shunting.

 PMID:10766893

  3. Study on the Automatic Detection Method and System of Multifunctional Hydrocephalus Shunt

    NASA Astrophysics Data System (ADS)

    Sun, Xuan; Wang, Guangzhen; Dong, Quancheng; Li, Yuzhong

    2017-07-01

    Aiming to the difficulty of micro pressure detection and the difficulty of micro flow control in the testing process of hydrocephalus shunt, the principle of the shunt performance detection was analyzed.In this study, the author analyzed the principle of several items of shunt performance detection,and used advanced micro pressure sensor and micro flow peristaltic pump to overcome the micro pressure detection and micro flow control technology.At the same time,This study also puted many common experimental projects integrated, and successfully developed the automatic detection system for a shunt performance detection function, to achieve a test with high precision, high efficiency and automation.

  4. Clinical assessment of cerebrospinal fluid dynamics in hydrocephalus. Guide to interpretation based on observational study.

    PubMed

    Weerakkody, R A; Czosnyka, M; Schuhmann, M U; Schmidt, E; Keong, N; Santarius, T; Pickard, J D; Czosnyka, Z

    2011-08-01

    The term hydrocephalus encompasses a range of disorders characterised by clinical symptoms, abnormal brain imaging and derangement of cerebrospinal fluid (CSF) dynamics. The ability to elucidate which patients would benefit from CSF diversion (a shunt or third ventriculostomy) is often unclear. Similar difficulties are often encountered in shunted patients to predict the scope for improvement by shunt re-adjustment or revision. In this study we aimed to update our knowledge of how key quantitative parameters describing CSF dynamics may be used in diagnosis of shunt-responsive hydrocephalus and in the assessment of shunt function. A number of quantitative parameters [including resistance to CSF outflow (Rcsf), pulse amplitude of intracranial pressure waveform (AMP), RAP index and slow vasogenic waves] were studies in 1423 patients with 2665 CSF infusion tests and 305 overnight intracranial pressure (ICP)-monitoring sessions over a 17 year period. We demonstrate our observations for typical values of Pb, Rcsf, AMP, slow vasogenic waves derived from infusion studies or overnight ICP monitoring in differentiating atrophy from shunt-responsive normal pressure hydrocephalus or acute hydrocephalus. From the same variables tested on shunted patients we demonstrate a standardised approach to help differentiate a properly-functioning shunt from underdrainage or overdrainage. Quantitative variables derived from CSF dynamics allow differentiation between clinically overlapping entities such as shunt-responsive normal pressure hydrocephalus and brain atrophy (not shunt responsive) as well as allowing the detection of shunt malfunction (partial or complete blockage) or overdrainage. This observational study is intended to serve as an update for our understanding of quantitative testing of CSF dynamics. © 2011 John Wiley & Sons A/S.

  5. Finger tapping and verbal fluency post-tap test improvement in INPH: its value in differential diagnosis and shunt-treatment outcomes prognosis.

    PubMed

    Liouta, Evangelia; Gatzonis, Stylianos; Kalamatianos, Theodosis; Kalyvas, Aristotelis; Koutsarnakis, Christos; Liakos, Faidon; Anagnostopoulos, Christos; Komaitis, Spyridon; Giakoumettis, Dimitris; Stranjalis, George

    2017-12-01

    Idiopathic normal pressure hydrocephalus (INPH) diagnosis is challenging as it can be mimicked by other neurological conditions, such as neurodegenerative dementia and motor syndromes. Additionally, outcomes after lumbar puncture (LP) tap test and shunt treatment may vary due to the lack of a common protocol in INPH assessment. The present study aimed to assess whether a post-LP test amelioration of frontal cognitive dysfunctions, characterizing this syndrome, can differentiate INPH from similar neurological conditions and whether this improvement can predict INPH post-shunt outcomes. Seventy-one consecutive patients referred for INPH suspicion and LP testing, were enrolled. According to the consensus guidelines criteria, 29 patients were diagnosed as INPH and 42 were assigned an alternative diagnosis (INPH-like group) after reviewing clinical, neuropsychological and imaging data, and before LP results. A comprehensive neuropsychological assessment for frontal executive, upper extremity fine motor functions, aphasias, apraxias, agnosias and gait evaluation were administered at baseline. Executive, fine motor functions and gait were re-examined post-LP test in all patients and post-shunt placement in INPH patients. Of the INPH patients, 86.2% showed cognitive amelioration in the post-LP test; in addition, all but one (97%) presented with neurocognitive and gait improvement post-shunt. Verbal phonological fluency and finger tapping task post-LP improvement predicted positive clinical outcome post-shunt. None of the INPH-like group presented with neurocognitive improvement post-LP. Post-LP amelioration of verbal fluency and finger tapping deficits can differentiate INPH from similar disorders and predict positive post-shunt clinical outcome in INPH. This becomes of great importance when gait assessment is difficult to perform in clinical practice.

  6. Are Shunt Revisions Associated with IQ in Congenital Hydrocephalus? A Meta -Analysis.

    PubMed

    Arrington, C Nikki; Ware, Ashley L; Ahmed, Yusra; Kulesz, Paulina A; Dennis, Maureen; Fletcher, Jack M

    2016-12-01

    Although it is generally acknowledged that shunt revisions are associated with reductions in cognitive functions in individuals with congenital hydrocephalus, the literature yields mixed results and is inconclusive. The current study used meta-analytic methods to empirically synthesize studies addressing the association of shunt revisions and IQ in individuals with congenital hydrocephalus. Six studies and three in-house datasets yielded 11 independent samples for meta-analysis. Groups representing lower and higher numbers of shunt revisions were coded to generate effect sizes for differences in IQ scores. Mean effect size across studies was statistically significant, but small (Hedges' g = 0.25, p < 0.001, 95 % CI [0.08, 0.43]) with more shunt revisions associated with lower IQ scores. Results show an association of lower IQ and more shunt revisions of about 3 IQ points, a small effect, but within the error of measurement associated with IQ tests. Although clinical significance of this effect is not clear, results suggest that repeated shunt revisions because of shunt failure is associated with a reduction in cognitive functions.

  7. Neuropsychological Assessment of Adult Patients with Shunted Hydrocephalus

    PubMed Central

    Bakar, Emel Erdogan

    2010-01-01

    Objective This study is planned to determine the neurocognitive difficulties of hydrocephalic adults. Methods The research group contained healthy adults (control group, n : 15), and hydrocephalic adults (n : 15). Hydrocephalic group consisted of patients with idiopathic aquaduct stenosis and post-meningitis hydrocephalus. All patients were followed with shunted hydrocephalus and not gone to shunt revision during last two years. They were chosen from either asymptomatic or had only minor symptoms without motor and sensorineural deficit. A neuropsychological test battery (Raven Standart Progressive Matrices, Bender-Gestalt Test, Cancellation Test, Clock Drawing Test, Facial Recognition Test, Line Orientation Test, Serial Digit Learning Test, Stroop Color Word Interference Test-TBAG Form, Verbal Fluency Test, Verbal Fluency Test, Visual-Aural Digit Span Test-B) was applied to all groups. Results Neuropsychological assessment of hydrocephalic patients demonstrated that they had poor performance on visual, semantic and working memory, visuoconstructive and frontal functions, reading, attention, motor coordination and executive function of parietal lobe which related with complex and perseverative behaviour. Eventually, these patients had significant impairment on the neurocognitive functions of their frontal, parietal and temporal lobes. On the other hand, the statistical analyses performed on demographic data showed that the aetiology of the hydrocephalus, age, sex and localization of the shunt (frontal or posterior parietal) did not affect the test results. Conclusion This prospective study showed that adult patients with hydrocephalus have serious neuropsychological problems which might be directly caused by the hydrocephalus; and these problems may cause serious adaptive difficulties in their social, cultural, behavioral and academic life. PMID:20379471

  8. The predictive value of cerebrospinal fluid tap-test in normal pressure hydrocephalus.

    PubMed

    Damasceno, B P; Carelli, E F; Honorato, D C; Facure, J J

    1997-06-01

    Eighteen patients (mean age of 66.5 years) with normal pressure hydrocephalus (NPH) underwent a ventriculo-peritoneal shunt surgery. Prior to operation a cerebrospinal fluid tap-test (CSF-TT) was performed with measurements of gait pattern and psychometric functions (memory, visuo-motor speed and visuo-constructive skills) before and after the removal of 50 ml CSF by lumbar puncture (LP). Fifteen patients improved and 3 were unchanged after surgery. Short duration of disease, gait disturbance preceding mental deterioration, wide temporal horns and small sulci on CT-scan were associated with good outcome after shunting. There was a good correlation between the results of CSF-TT and shunt surgery (chi 2 = 4.11, phi = 0.48, p < 0.05), with gait test showing highest correlation (r = 0.99, p = 0.01). In conclusion, this version of CSF-TT proved to be an effective test to predict improvement after shunting in patients with NPH.

  9. The effect of shunt surgery on neuropsychological performance in normal pressure hydrocephalus: a systematic review and meta-analysis.

    PubMed

    Peterson, Katie A; Savulich, George; Jackson, Dan; Killikelly, Clare; Pickard, John D; Sahakian, Barbara J

    2016-08-01

    We conducted a systematic review of the literature and used meta-analytic techniques to evaluate the impact of shunt surgery on neuropsychological performance in patients with normal pressure hydrocephalus (NPH). Twenty-three studies with 1059 patients were identified for review using PubMed, Web of Science, Google scholar and manual searching. Inclusion criteria were prospective, within-subject investigations of cognitive outcome using neuropsychological assessment before and after shunt surgery in patients with NPH. There were statistically significant effects of shunt surgery on cognition (Mini-Mental State Examination; MMSE), learning and memory (Rey Auditory Verbal Learning Test; RAVLT, total and delayed subtests), executive function (backwards digit span, phonemic verbal fluency, trail making test B) and psychomotor speed (trail making test A) all in the direction of improvement following shunt surgery, but with considerable heterogeneity across all measures. A more detailed examination of the data suggested robust evidence for improved MMSE, RAVLT total, RAVLT delayed, phonemic verbal fluency and trail making test A only. Meta-regressions revealed no statistically significant effect of age, sex or follow-up interval on improvement in the MMSE. Our results suggest that shunt surgery is most sensitive for improving global cognition, learning and memory and psychomotor speed in patients with NPH.

  10. Temporary Intraoperative Porto-Caval Shunts in Piggy-Back Liver Transplantation Reduce Intraoperative Blood Loss and Improve Postoperative Transaminases and Renal Function: A Meta-Analysis.

    PubMed

    Pratschke, Sebastian; Rauch, Alexandra; Albertsmeier, Markus; Rentsch, Markus; Kirschneck, Michaela; Andrassy, Joachim; Thomas, Michael; Hartwig, Werner; Figueras, Joan; Del Rio Martin, Juan; De Ruvo, Nicola; Werner, Jens; Guba, Markus; Weniger, Maximilian; Angele, Martin K

    2016-12-01

    The value of temporary intraoperative porto-caval shunts (TPCS) in cava-sparing liver transplantation is discussed controversially. Aim of this meta-analysis was to analyze the impact of temporary intraoperative porto-caval shunts on liver injury, primary non-function, time of surgery, transfusion of blood products and length of hospital stay in cava-sparing liver transplantation. A systematic search of MEDLINE/PubMed, EMBASE and PsycINFO retrieved a total of 909 articles, of which six articles were included. The combined effect size and 95 % confidence interval were calculated for each outcome by applying the inverse variance weighting method. Tests for heterogeneity (I 2 ) were also utilized. Usage of a TPCS was associated with significantly decreased AST values, significantly fewer transfusions of packed red blood cells and improved postoperative renal function. There were no statistically significant differences in primary graft non-function, length of hospital stay or duration of surgery. This meta-analysis found that temporary intraoperative porto-caval shunts in cava-sparing liver transplantation reduce blood loss as well as hepatic injury and enhance postoperative renal function without prolonging operative time. Randomized controlled trials investigating the use of temporary intraoperative porto-caval shunts are needed to confirm these findings.

  11. Ventricular shunt tap as a predictor of proximal shunt malfunction in children: a prospective study.

    PubMed

    Rocque, Brandon G; Lapsiwala, Samir; Iskandar, Bermans J

    2008-06-01

    The clinical diagnosis of cerebrospinal fluid (CSF) shunt malfunction can be challenging. In this prospective study, the authors evaluated a common method of interrogating shunts: the shunt tap; specifically, its ability to predict proximal malfunction. The authors performed standardized shunt taps in a consecutive series of cases involving children with suspected or proven shunt malfunction, assessing flow and, when possible, opening pressure. Data were collected prospectively, and results analyzed in light of surgical findings. A shunt tap was performed prior to 68 operative explorations in 51 patients. Of the 68 taps, 28 yielded poor or no CSF flow on aspiration. After 26 of these 28 procedures, proximal catheter obstruction was identified. After 28 taps with good CSF return and normal or low opening pressure, 18 shunts were found to have a proximal obstruction, 8 had no obstruction, and 2 had a distal obstruction. Another 12 taps with good CSF flow had high opening pressure; subsequent surgery showed distal obstruction in 11 of the shunts, and proximal obstruction in 1. The positive predictive value of poor flow was 93%, while good flow on shunt tap predicted adequate proximal catheter function in only 55% of cases. Poor flow of CSF on shunt tap is highly predictive of obstruction of the proximal catheter. Because not all patients with good flow on shunt tap underwent surgical shunt exploration, the specificity of this test cannot be determined. Nonetheless, a shunt tap that reveals good flow with a normal opening pressure can be misleading, and management of such cases should be based on clinical judgment.

  12. The relationship between CSF circulation and cerebrovascular pressure-reactivity in normal pressure hydrocephalus.

    PubMed

    Czosnyka, Z; van den Boogaard, F; Czosnyka, M; Momjian, S; Gelling, L; Pickard, J D

    2005-01-01

    Previously, we documented association between CSF circulation and transcranial-Doppler derived autoregulation in non-shunted patients suffering from hydrocephalus. In the present study we sought to investigate the relationship between the resistance to CSF outflow and pressure-reactivity both in shunted and non-shunted NPH patients. Sixty-eight patients (47 non-shunted and 21 shunted) with NPH have been examined as a part of routine diagnostic procedure. Resistance to CSF outflow (Rcsf) was measured using a ventricular constant rate infusion test. Cerebrovascular pressure-reactivity was assessed as a moving correlation coefficient (PRx) between coherent 'slow waves' of ICP and arterial blood pressure (ABP). This variable has previously been demonstrated to correlate with the autoregulation of CBF in patients following head injury. Results. In non-shunted patients cerebrovascular pressure-reactivity (PRx) was negatively correlated with Rcsf (R = -0.5; p < 0.0005). This relationship was inverted in shunted patients: a positive correlation between PRx and Rcsf was found (R = 0.51; p < 0.03). Cerebrovascular pressure-reactivity is disturbed in patients with normal resistance to CSF outflow, suggesting underlying cerebrovascular disease. This result confirms our previous finding where transcranial Doppler autoregulation was investigated. After shunting the pressure-reactivity strongly depends on shunt functioning and deteriorates when the shunt is blocked.

  13. Sub-xyphoid pleural drain as a determinant of functional capacity and clinical results after off-pump coronary artery bypass surgery: a randomized clinical trial.

    PubMed

    Guizilini, Solange; Alves, Daniel F; Bolzan, Douglas W; Cancio, Andreia S A; Regenga, Marisa M; Moreira, Rita S L; Trimer, Renata; Gomes, Walter J

    2014-09-01

    The aim of this trial was to compare functional capacity, pulmonary shunt fraction and clinical outcomes between patients undergoing pleurotomy with a pleural drain inserted in the sub-xyphoid position and patients with a pleural drain placed in the intercostal position after off-pump coronary artery bypass surgery. Patients were randomized into two groups according to the pleural drain site: Group II (n = 33 intercostal pleural drain); and Group SI (n = 35 sub-xyphoid pleural drain). Functional capacity was assessed by the distance covered on the 6-min walking test performed preoperatively and on postoperative day (POD) 5; in addition, pulmonary function test was determined preoperatively and on POD 1 and 5. Pulmonary shunt fraction was evaluated preoperatively and on POD 1, and clinical outcomes were recorded throughout the study. Group SI had better preservation of lung volumes and capacities in POD compared with Group II (P <0.05). Pulmonary shunt fraction increased in both groups postoperatively; however, Group SI showed a smaller pulmonary shunt fraction (0.26 ± 0.04 vs 0.21 ± 0.04%; P = 0.0014). Functional capacity was significantly reduced in both groups on POD 5; however, Group SI showed better preservation of functional capacity (P = 0.0001). Group SI had better postoperative clinical results, with lower incidence of atelectasis and pleural effusion (P <0.05), lower pain scores (P <0.0001), and shorter orotracheal intubation and hospitalization lengths (P <0.001). Sub-xyphoid pleural drain determined better functional capacity and exercise tolerance with a smaller pulmonary shunt fraction and improved clinical outcomes compared with intercostal pleural drainage after off-pump coronary artery bypass surgery. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Exercise Physiology and Pulmonary Hemodynamic Abnormality in PH Patients with Exercise Induced Venous-To-Systemic Shunt.

    PubMed

    Guo, Jian; Shi, Xue; Yang, Wenlan; Gong, Sugang; Zhao, Qinhua; Wang, Lan; He, Jing; Shi, Xiaofang; Sun, Xingguo; Liu, Jinming

    2014-01-01

    To identify the pulmonary hypertension (PH) patients who develop an exercise induced venous-to-systemic shunt (EIS) by performing the cardiopulmonary exercise test (CPET), analyse the changes of CPET measurements during exercise and compare the exercise physiology and resting pulmonary hemodynamics between shunt-PH and no-shunt-PH patients. Retrospectively, resting pulmonary function test (PFT), right heart catheterization (RHC), and CPET for clinical evaluation of 104 PH patients were studied. Considering all 104 PH patients by three investigators, 37 were early EIS+, 61 were EIS-, 3 were late EIS+, and 3 others were placed in the discordant group. PeakVO2, AT and OUES were all reduced in the shunt-PH patients compared with the no-shunt-PH subjects, whereas VE/VCO2 slope and the lowest VE/VCO2 increased. Besides, the changes and the response characteristics of the key CPET parameters at the beginning of exercise in the shunt group were notably different from those of the no shunt one. At cardiac catheterization, the shunt patients had significantly increased mean pulmonary artery pressure (mPAP), mean right atrial pressure (mRAP) and pulmonary vascular resistance (PVR), reduced cardiac output (CO) and cardiac index (CI) compared with the no shunt ones (P<0.05). Resting CO was significantly correlated with exercise parameters of AT (r = 0.527, P<0.001), OUES (r = 0.410, P<0.001) and Peak VO2 (r = 0.405, P<0.001). PVR was significantly, but weakly, correlated with the above mentioned CPET parameters. CPET may allow a non-invasive method for detecting an EIS and assessing the severity of the disease in PH patients.

  15. Effect of static axial loads on the lateral vibration attenuation of a beam with piezo-elastic supports

    NASA Astrophysics Data System (ADS)

    Götz, Benedict; Platz, Roland; Melz, Tobias

    2018-03-01

    In this paper, vibration attenuation of a beam with circular cross-section by resonantly shunted piezo-elastic supports is experimentally investigated for varying axial tensile and compressive beam loads. The beam's first mode resonance frequency, the general electromechanical coupling coefficient and static transducer capacitance are analyzed for varying axial loads. All three parameter values are obtained from transducer impedance measurements on an experimental test setup. Varying axial beam loads manipulate the beam's lateral bending stiffness and, thus, lead to a detuning of the resonance frequencies. Furthermore, they affect the general electromechanical coupling coefficient of transducer and beam, an important modal quantity for shunt-damping, whereas the static transducer capacitance is nearly unaffected. Frequency transfer functions of the beam with one piezoe-elastic support either shunted to an RL-shunt or to an RL-shunt with negative capacitance, the RLC-shunt, are compared for varying axial loads. It is shown that the beam vibration attenuation with the RLC-shunt is less influenced by varying axial beam loads and, therefore, is more robust against detuning.

  16. Successful laparoscopic division of a patent ductus venosus: report of a case.

    PubMed

    Hara, Yoshiaki; Sato, Yoshinobu; Yamamoto, Satoshi; Oya, Hiroshi; Igarashi, Masato; Abe, Satoshi; Kokai, Hidenaka; Miura, Kohei; Suda, Takeshi; Nomoto, Minoru; Aoyagi, Yutaka; Hatakeyama, Katsuyoshi

    2013-04-01

    Patent ductus venosus (PDV) is a rare condition of a congenital portosystemic shunt from the umbilical vein to the inferior vena cava. This report presents the case of an adult patient with PDV, who was successfully treated with laparoscopic shunt division. A 69-year-old male was referred with hepatic encephalopathy. Contrast-enhanced CT revealed a large connection between the left portal vein and the inferior vena cava, which was diagnosed as PDV. The safety of a shunt disconnection was confirmed using a temporary balloon occlusion test for the shunt, and the shunt division was performed laparoscopically. The shunt was carefully separated from the liver parenchyma with relative ease, and then divided using a vascular stapler. Portal flow was markedly increased after the operation, and the liver function of the patient improved over the 3-month period after surgery. Although careful interventional evaluation for portal flow is absolutely imperative prior to surgery, a minimally invasive laparoscopic approach can be safely used for treating PDV.

  17. Cerebral blood flow velocity and vasomotor reactivity before and after shunting surgery in patients with normal pressure hydrocephalus.

    PubMed

    Lee, E J; Hung, Y C; Chang, C H; Pai, M C; Chen, H H

    1998-01-01

    The purpose of this study was to evaluate pre- and post-shunting haemodynamic changes and their correlation with the clinical results in normal pressure hydrocephalus (NPH). Accordingly, eleven demented patients with clinical signs suggestive of NPH received examinations of cerebral blood flow velocity (BFV) and vasomotor reactivity (VMR) by transcranial Doppler sonography with carbogen testing before and after shunt treatment. Computerized tomography (CT), clinical assessment and neuropsychological grading were performed prior to and at 3 months following surgery. A control group consisting of 10 patients was included to establish baseline data. The pre-operative CBF studies in the anterior cerebral artery (ACA) and the middle cerebral artery (MCA) revealed the NPH patients did not have significant decreases of BFVs, but had significant decreases of carbogen VMR (P < 0.05). After shunting, there were no significant changes of the BFVs as compared with the pre-shunting data. The post-shunting VMR of the ACA was significantly higher than the pre-shunting one (p < 0.05), but there was no variation in that of the MCA. Both the values of post-shunting VMR in ACA and the post-shunting increase in VMR in MCA of the 7 shunt-responsive patients who improved mentally and in other symptoms were significantly higher than those of patients without improvement (p < 0.05). In addition, the five patients with gait improvement showed significantly higher values of post-shunting VMR of ACA and the post-shunting increase of VMR for both ACA and MCA when compared with those patients without gait improvement (p < 0.05, respectively). Our study supports the view that patients with NPH had various degrees of impaired VMR in both the ACA and the MCA, but showed insignificant reduction in BFVs, indicating a compensatory mechanism of CBF over time to accommodate the subnormal state of cerebral perfusion pressure. Shunt placement would improve the VMR in responsive patients. Postoperatively, an increase of VMR tends to accompany improvement of the functional state: that in the MCA alone is associated with symptomatic improvement in mental function and that increase in VMR in both the ACA and the MCA with improvement in gait, respectively.

  18. [Surgical treatment of normal pressure hydrocephalus].

    PubMed

    Svendsen, F; Hugdahl, K; Wester, K

    2001-05-30

    Normal pressure hydrocephalus (NPH) is an important diagnosis to keep in mind, i.e. the possibility that NPH and not a neurodegenerative disease causes the patient's symptoms with ataxia, urinary incontinence and dementia. Clinical improvement, sometimes a complete reversal of the symptoms, may be seen after a simple surgical procedure. This prospective study was performed by testing eight consecutively shunted patients with a walking test and a cognitive test battery pre- and postoperatively. Improvement 3-4 months after the shunting procedure suggests that NPH was present in six of eight patients. Walking ability was improved after surgery, also in patients with severe dementia. Severe dementia caused by NPH is hardly reversible, though cognitive tests may indicate some improvement. However, early surgical treatment of NPH in patients not suffering from a dementia according to the Mini Mental Status Test may bring improvement in some cognitive functions. Patients with both clinical and radiological signs of normal pressure hydrocephalus should be offered a shunting procedure.

  19. The sensibility and specificity of cerebral oximetry, measured by INVOS - 4100, in patients undergoing carotid endarterectomy compared with awake testing.

    PubMed

    Stilo, F; Spinelli, F; Martelli, E; Pipitó, N; Barillà, D; De Caridi, G; Benedetto, F; Risitano, D; Noto, A; Messina, R; David, A

    2012-10-01

    Selective shunting during carotid endarterectomy (CEA) is advocated to reduce shunt-related stroke. Cerebral monitoring is essential for temporary carotid shunting. Many techniques are available for cerebral monitoring; however, none is superior to monitoring the patient's neurological status (awake testing) while performing the procedure under local anesthesia (LA). Cerebral oximetry (CO) has previously been used to show the adequacy of cerebral circulation in patients undergoing CEA. This investigation was designed to compare the performance of the INVOS-4100 cerebral oximeter and the neurologic functions, by means of detecting cerebral ischemia induced by carotid cross-clamping, in patients undergoing CEA under LA, namely cervical plexus block. Patients scheduled for CEA under LA were included. Patients converted to general anesthesia (GA) or other types of operations other than CEA were excluded from this study. We enrolled 100 consecutive patients from January 2009 to December 2010. Bilateral regional cerebrovascular oxygen saturation (rSO(2)) was monitored in all patients, in addition to the awake testing. Changes in rSO(2) following carotid artery clamping were recorded. A drop greater than 20% was considered as an indicator of cerebral ischemia that might predict the need for carotid shunting. Patients were only shunted based on the awake testing. Of the 100 patients undergoing CEA under LA, 9 showed a significant drop in rSO(2) (range: 22.6-32.8%, mean: 26.4%): only three of them required shunting, while the remaining 6 had no changes in consciousness after internal carotid artery (ICA) cross-clamping and it was not necessary to place a shunt (false positive). Compared to the preclamping values, a significant decrease in rSO(2) was found on the hemisphere of the operated side, while no significant change was observed contralaterally. Ninety-one patients had no significant changes of CO values: in 89 of them there was no consciousness deterioration, so we didn't place a shunt (true negative), but 2 patients showing a non-significant post-clamping decline in CO saturation (1.5% and 18.2%) required shunting based on the awake testing (2 false negative). In the current study, the median drop in rSO(2) was 19% (range: 1.5-26.4%) in the 5 patients that required shunting. This represents a sensitivity of 60% and a specificity of 25% for CO in comparison to the awake testing. The results of this study suggest that the usefulness of CO in predicting cerebral ischemia is modest. Cerebral monitoring with INVOS-4100 has a high negative predictive value, but the positive predictive value is low.

  20. Functional Changes of Diaphragm Type Shunt Valves Induced by Pressure Pulsation

    NASA Astrophysics Data System (ADS)

    Lee, Chong-Sun; Suh, Chang-Min; Ra, Young-Shin

    Shunt valves used to treat patients with hydrocephalus were tested to investigate influence of pressure pulsation on their flow control characteristics. Our focus was on flow dynamic and functional changes of the small and thin diaphragms in the valves that serve as the main flow control mechanism and are made from silicone elastomer. Firstly, pressure-flow control curves were compared under pulsed and steady flow (without pulsation) conditions. Secondly, functional changes of the valves were tested after a long-term continuous pulsation with a peristaltic pump. Thirdly, flushing procedures selectively conducted by neurosurgeons were simulated with a fingertip pressed on the dome of the valves. As 20cc/hr of flow rate was adjusted at a constant pressure, application of 40mmH2O of pressure pulse increased flow rate through shunt valves more than 60%. As a 90cm length silicone catheter was connected to the valve outlet, increase in the flow rate was substantially reduced to 17.5%. Pressure-flow control characteristics of some valves showed significant changes after twenty-eight days of pressure pulsation at 1.0 Hz under 50.0cc/hr of flow rate. Flushing simulation resulted in temporary decrease in the pressure level. It took three hours to fully recover the normal pressure-flow control characteristics after the flushing. Our results suggest that shunt valves with a thin elastic diaphragm as the main flow control mechanism are sensitive to intracranial pressure pulsation or pressure spikes enough to change their pressure-flow control characteristics.

  1. Five-year outcome of normal pressure hydrocephalus with or without a shunt: predictive value of the clinical signs, neuropsychological evaluation and infusion test.

    PubMed

    Savolainen, S; Hurskainen, H; Paljärvi, L; Alafuzoff, I; Vapalahti, M

    2002-06-01

    Between 1993-1995, 51 patients under 75 years of age with clinical symptoms and CT-based diagnosis of normal pressure hydrocephalus were investigated prospectively in order to clarify the value of neuropsychological tests, clinical symptoms and signs and infusion test in the differential diagnosis and prediction of outcome in normal pressure hydrocephalus. Patients had a thorough neurological examination, and neuropsychological evaluation. A 24-hour intraventricular ICP-measurement, infusion test, neurophysiological investigations and MRI study were performed, and a cortical biopsy was obtained. The ICP measurement defined the need for a shunt. All 51 patients were re-examined three and twelve months later. The final follow-up was accomplished five years postoperatively. 25 of the patients needed a shunt operation. One year after a shunt placement 72% of these patients had a good recovery concerning activities of daily living, 58% benefited in their urinary incontinence and 57% walked better. During the 5 years of follow-up 8 patients with shunt and 9 without shunt had died. Positive effect of shunting remained. Only one neuropsychological test, recognition of words test, distinguishes the patients with the need for a shunt. Simple mini mental examination test was not different in those who improved. In the postoperative follow-up patients with shunt showed no change in neuropsychological tests even if they were subjectively better. The infusion test was of no value in diagnosing NPH. The 16 patients with Alzheimer's disease did worse after one year than those without pathological changes, but the mortality was not increased. Specific neuropsychological tests are of little value in diagnosing NPH. Mini-Mental status examination was neither of value in diagnosing NPH nor in prediction of the outcome. In this study the infusion test did not improve diagnostic accuracy of NPH, but shunt placement relieves urinary incontinence and walking disability in patients with increased ICP. The patients with positive Alzheimer diagnosis on biopsy did not improve.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erinjeri, Joseph P., E-mail: erinjerj@mskcc.org; Deodhar, Ajita; Thornton, Raymond H.

    Hepatic encephalopathy is considered a contraindication to hepatic artery embolization. We describe a patient with a well-differentiated neuroendocrine tumor metastatic to the liver with refractory hepatic encephalopathy and normal liver function tests. The encephalopathy was refractory to standard medical therapy with lactulose. The patient's mental status returned to baseline after three hepatic artery embolization procedures. Arteriography and ultrasound imaging before and after embolization suggest that the encephalopathy was due to arterioportal shunting causing hepatofugal portal venous flow and portosystemic shunting. In patients with a primary or metastatic well-differentiated neuroendocrine tumor whose refractory hepatic encephalopathy is due to portosystemic shunting (rathermore » than global hepatic dysfunction secondary to tumor burden), hepatic artery embolization can be performed safely and effectively.« less

  3. Passively Shunted Piezoelectric Damping of Centrifugally-Loaded Plates

    NASA Technical Reports Server (NTRS)

    Duffy, Kirsten P.; Provenza, Andrew J.; Trudell, Jeffrey J.; Min, James B.

    2009-01-01

    Researchers at NASA Glenn Research Center have been investigating shunted piezoelectric circuits as potential damping treatments for turbomachinery rotor blades. This effort seeks to determine the effects of centrifugal loading on passively-shunted piezoelectric - damped plates. Passive shunt circuit parameters are optimized for the plate's third bending mode. Tests are performed both non-spinning and in the Dynamic Spin Facility to verify the analysis, and to determine the effectiveness of the damping under centrifugal loading. Results show that a resistive shunt circuit will reduce resonant vibration for this configuration. However, a tuned shunt circuit will be required to achieve the desired damping level. The analysis and testing address several issues with passive shunt circuit implementation in a rotating system, including piezoelectric material integrity under centrifugal loading, shunt circuit implementation, and tip mode damping.

  4. Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush.

    PubMed

    Groth, Sylvia L; Greider, Kelsi L; Sponsel, William Eric

    2015-01-01

    To assess the utility of viscoelastic injection to induce bleb expansion and decrease intraocular pressure (IOP) in eyes with encapsulated glaucoma tube shunt blebs. Case series. Forty-three glaucomatous eyes, including 13 eyes with congenital, 13 uveitic, 5 neovascular, 5 open angle, 4 narrow angle and 3 traumatic glaucomas. Methods, interventions or testing: All patients underwent viscoelastic flush procedure. A pre-bent 27 or 30-gauge cannula was passed through a 25-gauge paracentesis, advanced over the iris across the anterior chamber, and insinuated into the tube shunt lumen. Once the cannula was firmly lodged in position, 0.45 to 0.85 ml of viscoelastic was injected to hyperinflate the bleb. Paired t-tests were performed comparing preoperative IOP and number of medications used preoperatively vs levels measured at 1, 6, 12, 18 and 24 months. Intraocular pressure was reduced from a mean preoperative level of 26.0 ± 1.2 (sem) mm Hg to 15.8 ± 1.0 at 1 month, remaining stable thereafter at each 6-month interval with 15.1 ± 1.1 mm Hg at 24 months (p < 0.0001). Medication use did not vary significantly from baseline. Pressure remained < 21 mm Hg after 2 years in 85% of eyes cannulated within 1 year of primary tube shunt implantation (n = 23), and in 62% of eyes cannulated more than 1 year after tube shunt placement (n = 20). Tube shunt expansion with bolus viscoelastic flush successfully restored encapsulated bleb function, providing a substantial (~10 mm Hg) IOP decrease into the mid-normal pressure range. This persisted in the majority of treated eyes for the entire study period. How to cite this article: Groth SL, Greider KL, Sponsel WE. Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush. J Curr Glaucoma Pract 2015;9(3):73-76.

  5. [The role of computerized rheoencephalography in the assessment of normal pressure hydrocephalus. Preliminary report].

    PubMed

    Traczewski, Wojciech; Moskała, Marek; Szwabowska, Dorota; Gościński, Igor; Krupa, Mariusz; Polak, Jarosław

    2005-01-01

    It is generally agreed that the positive result of lumbar cerebrospinal fluid (CSF) withdrawal offers a reliable means for selection of patients likely to respond to shunting in normal pressure hydrocephalus (NPH). However the studies of cerebral hemodynamics in NPH are performed Routinely only in few neurosurgical centers. We therefore studied the effect of CSF withdrawal on cerebrovascular autoregulation (CVA) in this condition by means of computerized rheoencephalography [REG]. The study group consisted of 27 patients with presumed posttraumatic NPH. In each patient both the tap test and infusion test were performed. Psychometric tests and rheoencephalographic examinations were made twice: before and after CSF withdrawal. The obvious restoration of the functional state of CVA after CSF withdrawal was considered as a positive result of the tap test. Fourteen patients with a positive tap test and/or with resistance to CSF outflow (Rout) of more than 11 mmHg/ml/min were shunted. The improvement was obtained in 10 of them. Only one patient with a positive tap test did not improve. Our study suggests that restoration of CVA after CSF withdrawal is associated with high likelihood of shunt success, but not vice versa. Evaluation of CVA using REG seems to offer a new diagnostic tool in selecting patients likely to respond to shunting. Further studies are necessary to optimize the amount of CSF withdrawal, the delay between CSF withdrawal and control examinations and methodology of neuropsychological examinations.

  6. Turning crocodilian hearts into bird hearts: growth rates are similar for alligators with and without right-to-left cardiac shunt

    PubMed Central

    Eme, John; Gwalthney, June; Owerkowicz, Tomasz; Blank, Jason M.; Hicks, James W.

    2010-01-01

    The functional and possible adaptive significance of non-avian reptiles' dual aortic arch system and the ability of all non-avian reptiles to perform central vascular cardiac shunts have been of great interest to comparative physiologists. The unique cardiac anatomy of crocodilians – a four-chambered heart with the dual aortic arch system – allows for only right-to-left (R–L; pulmonary bypass) cardiac shunt and for surgical elimination of this shunt. Surgical removal of the R–L shunt, by occluding the left aorta (LAo) upstream and downstream of the foramen of Panizza, results in a crocodilian with an obligatory, avian/mammalian central circulation. In this study, R–L cardiac shunt was eliminated in age-matched, female American alligators (Alligator mississippiensis; 5–7 months of age). We tested the hypothesis that surgical elimination of R–L cardiac shunt would impair growth (a readily measured proxy for fitness) compared with sham-operated, age-matched controls, especially in animals subjected to exhaustive exercise. While regular exercise caused a decrease in size (snout-to-vent length, head length and body mass), elimination of the capacity for R–L cardiac shunt did not greatly reduce animal growth, despite a chronic ventricular enlargement in surgically altered juvenile alligators. We speculate that, despite being slightly smaller, alligators with an occluded LAo would have reached sexual maturity in the same breeding season as control alligators. This study suggests that crocodilian R–L cardiac shunt does not provide an adaptive advantage for juvenile alligator growth and supports the logic that cardiac shunts persist in crocodilians because they have not been selected against. PMID:20639429

  7. A physical framework for implementing virtual models of intracranial pressure and cerebrospinal fluid dynamics in hydrocephalus shunt testing.

    PubMed

    Venkataraman, Pranav; Browd, Samuel R; Lutz, Barry R

    2016-09-01

    OBJECTIVE The surgical placement of a shunt designed to resolve the brain's impaired ability to drain excess CSF is one of the most common treatments for hydrocephalus. The use of a dynamic testing platform is an important part of shunt testing that can faithfully reproduce the physiological environment of the implanted shunts. METHODS A simulation-based framework that serves as a proof of concept for enabling the application of virtual intracranial pressure (ICP) and CSF models to a physical shunt-testing system was engineered. This was achieved by designing hardware and software that enabled the application of dynamic model-driven inlet and outlet pressures to a shunt and the subsequent measurement of the resulting drainage rate. RESULTS A set of common physiological scenarios was simulated, including oscillations in ICP due to respiratory and cardiac cycles, changes in baseline ICP due to changes in patient posture, and transient ICP spikes caused by activities such as exercise, coughing, sneezing, and the Valsalva maneuver. The behavior of the Strata valve under a few of these physiological conditions is also demonstrated. CONCLUSIONS Testing shunts with dynamic ICP and CSF simulations can facilitate the optimization of shunts to be more failure resistant and better suited to patient physiology.

  8. Validation of a noninvasive test routinely used in otology for the diagnosis of cerebrospinal fluid shunt malfunction in patients with normal pressure hydrocephalus.

    PubMed

    Sakka, Laurent; Chomicki, Alexandre; Gabrillargues, Jean; Khalil, Toufic; Chazal, Jean; Avan, Paul

    2016-02-01

    Ventriculoperitoneal shunting is the first-line treatment for normal pressure hydrocephalus. Noninvasive auditory tests based on recorded otoacoustic emissions were assessed, as currently used for universal neonatal hearing screenings, for the diagnosis of cerebrospinal fluid shunt malfunction. The test was designed based on previous works, which demonstrated that an intracranial pressure change induces a proportional, characteristic, otoacoustic-emission phase shift. Forty-four patients with normal pressure hydrocephalus (23 idiopathic and 21 secondary cases) were included in this prospective observational study. The male:female sex ratio was 1.44, the age range was 21-87 years (mean age 64.3 years), and the range of the follow-up period was 1-3 years (mean 20 months). Patients were implanted with a Sophy SU8 adjustable-pressure valve as the ventriculoperitoneal shunt. The phase shifts of otoacoustic emissions in response to body tilt were measured preoperatively, immediately postoperatively, and at 3-6 months, 7-15 months, 16-24 months, and more than 24 months postoperatively. Three groups were enrolled: Group 1, 19 patients who required no valve opening-pressure adjustment; Group 2, 18 patients who required valve opening-pressure adjustments; and Group 3, 7 patients who required valve replacement. In Group 1, phase shift, which was positive before surgery, became steadily negative after surgery and during the follow-up. In Group 2, phase shift, which was positive before surgery, became negative immediately after surgery and increasingly negative after a decrease in the valve-opening pressure. In Group 3, phase shift was positive in 6 cases and slightly negative in 1 case before revision, but after revision phase shift became significantly negative in all cases. Otoacoustic emissions noninvasively reflect cerebrospinal fluid shunt function and are impacted by valve-opening pressure adjustments. Otoacoustic emissions consistently diagnosed shunt malfunction and predicted the need for surgical revision. The authors' diagnostic test, which can be repeated without risk or discomfort by an unskilled operator, may address the crucial need of detecting valve dysfunction in patients with poor clinical outcome after shunt surgery.

  9. Attention lapses in children with spina bifida and hydrocephalus and children with attention-deficit/hyperactivity disorder.

    PubMed

    De la Torre, Gabriel G; Martin, Alba; Cervantes, Elizabeth; Guil, Rocio; Mestre, Jose M

    2017-08-01

    Attentional lapses are usually defined as temporary and often brief shifts of attention away from some primary task to unrelated internal information processing. This study addressed the incidence of attention lapses and differences in attentional functioning in 30 children with attention-deficit/hyperactivity disorder (ADHD), 26 healthy children, and 29 children with spina bifida myelomeningocele and hydrocephalus (SBH). Assessments were conducted using computerized tonic and phasic attention tests, the Symbol Digit Modalities Test (SDMT), and the Trail Making Test Form B (TMT-B). The group with SBH differed from normal controls on cognitive measures of attention and executive functions. The ADHD group obtained lower scores than the SBH group and healthy children. ANOVA results showed that there was an effect of shunt revisions and shunt-related infections on neuropsychological performance. Lapses of attention together with reaction time may thus represent important factors for the understanding of cognitive deficits in SBH.

  10. Failure Engineering Study and Accelerated Stress Test Results for the Mars Global Surveyor Spacecraft's Power Shunt Assemblies

    NASA Technical Reports Server (NTRS)

    Gibbel, Mark; Larson, Tim

    1999-01-01

    Due to a post launch failure of a part a new plan for the Mars Global Surveyor was developed. This new plan involved the addition of many deep thermal cycles to the Power Shunt Assemblies (PSA's). This new plan exceeds the previous acceptance cold level, and fatigue life on packaging design. This presentation reviews the experiments that were used to test the capabilities of the PSA to function in the new situation. It also reviews the analyses preformed to verify the most likely failure mechanism, and the likelihood that these failures would impact the new mission requirements.

  11. Cerebrospinal Fluid Lumbar Tapping Utilization for Suspected Ventriculoperitoneal Shunt Under-Drainage Malfunctions.

    PubMed

    Lee, Jong-Beom; Ahn, Ho-Young; Lee, Hong-Jae; Yang, Ji-Ho; Yi, Jin-Seok; Lee, Il-Woo

    2017-01-01

    The diagnosis of shunt malfunction can be challenging since neuroimaging results are not always correlated with clinical outcomes. The purpose of this study was to evaluate the efficacy of a simple, minimally invasive cerebrospinal fluid (CSF) lumbar tapping test that predicts shunt under-drainage in hydrocephalus patients. We retrospectively reviewed the clinical and radiological features of 48 patients who underwent routine CSF lumbar tapping after ventriculoperitoneal shunt (VPS) operation using a programmable shunting device. We compared shunt valve opening pressure and CSF lumbar tapping pressure to check under-drainage. The mean pressure difference between valve opening pressure and CSF lumbar tapping pressure of all patients were 2.21±24.57 mmH 2 O. The frequency of CSF lumbar tapping was 2.06±1.26 times. Eighty five times lumbar tapping of 41 patients showed that their VPS function was normal which was consistent with clinical improvement and decreased ventricle size on computed tomography scan. The mean pressure difference in these patients was -3.69±19.20 mmH 2 O. The mean frequency of CSF lumbar tapping was 2.07±1.25 times. Fourteen cases of 10 patients revealed suspected VPS malfunction which were consistent with radiological results and clinical symptoms, defined as changes in ventricle size and no clinical improvement. The mean pressure difference was 38.07±23.58 mmH 2 O. The mean frequency of CSF lumbar tapping was 1.44±1.01 times. Pressure difference greater than 35 mmH 2 O was shown in 2.35% of the normal VPS function group (2 of 85) whereas it was shown in 64.29% of the suspected VPS malfunction group (9 of 14). The difference was statistically significant ( p =0.000001). Among 10 patients with under-drainage, 5 patients underwent shunt revision. The causes of the shunt malfunction included 3 cases of proximal occlusion and 2 cases of distal obstruction and valve malfunction. Under-drainage of CSF should be suspected if CSF lumbar tapping pressure is 35 mmH 2 O higher than the valve opening pressure and shunt malfunction evaluation or adjustment of the valve opening pressure should be made.

  12. The prognostic value of clinical characteristics and parameters of cerebrospinal fluid hydrodynamics in shunting for idiopathic normal pressure hydrocephalus.

    PubMed

    Delwel, E J; de Jong, D A; Avezaat, C J J

    2005-10-01

    It is difficult to predict which patients with symptoms and radiological signs of normal pressure hydrocephalus (NPH) will benefit from a shunting procedure and which patients will not. Risk of this procedure is also higher in patients with NPH than in the overall population of hydrocephalic patients. The aim of this study is to investigate which clinical characteristics, CT parameters and parameters of cerebrospinal fluid dynamics could predict improvement after shunting. Eighty-three consecutive patients with symptoms and radiological signs of NPH were included in a prospective study. Parameters of the cerebrospinal fluid dynamics were measured by calculation of computerised data obtained by a constant-flow lumbar infusion test. Sixty-six patients considered candidates for surgery were treated with a medium-pressure Spitz-Holter valve; in seventeen patients a shunting procedure was not considered indicated. Clinical and radiological follow-up was performed for at least one year postoperatively. The odds ratio, the sensitivity and specificity as well as the positive and negative predictive value of individual and combinations of measured parameters did not show a statistically significant relation to clinical improvement after shunting. We conclude that neither individual parameters nor combinations of measured parameters show any statistically significant relation to clinical improvement following shunting procedures in patients suspected of NPH. We suggest restricting the term normal pressure hydrocephalus to cases that improve after shunting and using the term normal pressure hydrocephalus syndrome for patients suspected of NPH and for patients not improving after implantation of a proven well-functioning shunt.

  13. Lithium battery discharge tests

    NASA Technical Reports Server (NTRS)

    Johnson, C. J.

    1980-01-01

    The long term discharge of a variety of lithium cells was characterized and the susceptibility of the cells to chemical variation during the slow discharge was tested. A shunt resistor was set across the terminals to monitor the voltage as a function of time. Failures were identified by premature voltage drops.

  14. Diamox((R)) challenge test to decide indications for cerebrospinal fluid shunting in normal pressure hydrocephalus.

    PubMed

    Miyake, H; Ohta, T; Kajimoto, Y; Deguchi, J

    1999-01-01

    The indications for cerebrospinal fluid (CSF) shunting in patients with normal pressure hydrocephalus (NPH) have not been established. Establishment of clear-cut indications for this procedure is essential to ensure cost-effective, and safe treatment. We report the usefulness of the Diamox((R)) challenge test in evaluating indications for CSF shunting in patients with NPH. Pre- and post-operative responses in cerebral blood flow (CBF) and intracranial pressure (ICP) to intravenous administration of Diamox((R)) 1000mg (Diamox((R)) administration) were analysed in 41 patients with NPH who were treated by ventriculoperitoneal (VP) shunt with a programmable valve and an on-off valve. The preoperative response of ICP to Diamox((R)) administration was more than 10 mmHg in most patients in whom the shunt was effective (shunt effective group), however, it was less than 10 mmHg in most patients in whom the shunt was ineffective (shunt non-effective group). Furthermore, the postoperative response of ICP to Diamox((R)) administration decreased to less than 10 mmHg in most patients in the shunt effective group. The increases in CBF in response to Diamox((R)) administration were similar in the two groups both before and after placement of the VP shunt. Patients in whom ICP increased by more than 10 mmHg in response to Diamox((R)) administration were regarded to have poor CSF circulation and to thus be candidates for CSF shunting. The Diamox((R)) challenge test is a simple, safe procedure, useful in evaluating the response to treatment.

  15. Index of cerebrospinal compensatory reserve in hydrocephalus.

    PubMed

    Kim, Dong-Joo; Czosnyka, Zofia; Keong, Nicole; Radolovich, Danila K; Smielewski, Peter; Sutcliffe, Michael P F; Pickard, John D; Czosnyka, Marek

    2009-03-01

    An index of cerebrospinal compensatory reserve (RAP) has been introduced as a potential descriptor of neurological deterioration after head trauma. It is numerically computed as a linear correlation coefficient between the mean intracranial pressure and the pulse amplitude of the pressure waveform. We explore how RAP varies with different forms of physiological or nonphysiological intracranial volume loads in adult hydrocephalus, with and without a functioning cerebrospinal fluid (CSF) shunt. A database of intracranial pressure recordings during CSF infusion studies and overnight monitoring in hydrocephalic patients was reviewed for clinical comparison of homogeneous subgroups of patients with hypothetical differences of pressure-volume compensatory reserve. The database includes 980 patients of mixed etiology: idiopathic normal pressure hydrocephalus (NPH), 47%; postsubarachnoid hemorrhage NPH, 12%; noncommunicating hydrocephalus, 22%; others, 19%. All CSF compensatory parameters were calculated by using intracranial pressure waveforms. In NPH, RAP correlated strongly with the resistance to CSF outflow (r(s) = 0.35; P = 0.045), but weakly correlated with ventriculomegaly (r(s) = 0.13; P = 0.41). In idiopathic nonshunted NPH patients, RAP did not correlate significantly with elasticity calculated from the CSF infusion test (r(s) = 0.11; P = 0.21). During infusion studies, RAP increased in comparison to values recorded at baseline (from a median of 0.45-0.86, P = 0.14 * 10(-8)), indicating a narrowing of the volume-pressure compensatory reserve. During B-waves associated with the REM (rapid eye movement) phase of sleep, RAP increased from a median of 0.53 to 0.89; P = 1.2 * 10(-5). After shunting, RAP decreased (median before shunting, 0.59; median after shunting, 0.34; P = 0.0001). RAP also showed the ability to reflect the functional state of the shunt (patent shunt median, 0.36; blocked shunt median, 0.84; P = 0.0002). RAP appears to characterize pressure-volume compensatory reserve in patients with hydrocephalus.

  16. Baseline neuropsychological profile and cognitive response to cerebrospinal fluid shunting for idiopathic normal pressure hydrocephalus.

    PubMed

    Thomas, George; McGirt, Matthew J; Woodworth, Graeme; Heidler, Jennifer; Rigamonti, Daniele; Hillis, Argye E; Williams, Michael A

    2005-01-01

    To evaluate neurocognitive changes and predict neurocognitive outcome after ventriculoperitoneal shunting for idiopathic normal pressure hydrocephalus (INPH). Reports of neurocognitive response to shunting have been variable and studies that predict cognitive outcomes after shunting are limited. We reviewed our experience with cognitive outcomes for INPH patients who were selected for shunting based on abnormal cerebrospinal fluid (CSF) pressure monitoring and positive response in any of the NPH symptoms following large volume CSF drainage. Forty-two INPH patients underwent neurocognitive testing and Folstein Mini-Mental State Examination (MMSE) prior to shunting. Neurocognitive testing or MMSEwere performed at least 3 months after shunt insertion. Significant improvement in a neurocognitive subtest was defined as improvement by one standard deviation (1 SD) for the patient's age, sex and education level. Significant improvement in overall neurocognitive outcome was defined as a 4-point improvement in MMSE or improvement by 1 SD in 50% of the administered neurocognitive subtests. Nonparametric tests were used to assess changes. Predictors of outcome were assessed via logistic regression analysis. Twenty-two patients (52.3%) showed overall neurocognitive improvement, and significant improvement was seen in tests of verbal memory and psychomotor speed. Predictive analysis showed that patients scoring more than 1 SD below mean at baseline on verbal memory immediate recall were fourfold less likely to show overall cognitive improvement, and sixfold less likely if also associated with visuoconstructional deficit or executive dysfunction. Verbal memory scores at baseline were higher in patients who showed overall cognitive improvement. Shunting INPH patients on the basis of CSF pressure monitoring and drainage response shows a significant rate of cognitive improvement, and baseline neurocognitive test scores may distinguish patients likely to respond to shunt surgery from those who will not. Copyright (c) 2005 S. Karger AG, Basel.

  17. [Liver transplantation preserving the vena cava and a temporary portocaval shunt].

    PubMed

    Hesse, U J; Berrevoet, F; Troisi, R; Mortier, E; Decruyenaere, J; Pattyn, P; de Hemptinne, B

    1999-02-01

    The experience with laterolateral cavocavostomy for hepatovenous reconstruction in liver transplantation is reviewed with and without the use of a temporary portocaval shunt. A total of 65 liver transplantations were analyzed. In 49 transplantations a laterolateral cavocaval anastomosis was performed (group I). In group II (n = 16) the same technique was used after a temporary portal caval shunt was constructed. Mean arterial pressure (mmHg): group I 128 +/- 34; group II 109 +/- 32. Cardiac output (l/min) decrease during the anhepatic phase was 2.3 +/- 1.9 and 1.2 +/- 1.5, respectively (P < 0.05). The peroperative blood loss measured as the number of packed cells transfused was 16.4 +/- 15.8 versus 1.2 +/- 2.3 (P < 0.04) and fresh frozen plasma 19.0 +/- 14.7 versus 3.7 +/- 4.0 (P < 0.02). Course on ICU (days), liver function tests, renal function and the need for reoperation because of bleeding were not statistically significantly different between the groups. One-year patient survival was 82.7 and 85.7%, respectively. In conclusion, we found that despite preservation of the caval flow during hepatectomy, the additional use of a temporary portocaval shunt was advantageous with regard to peroperative hemorrhage and hemodynamic stability and can potentially facilitate implantation of the liver graft.

  18. Initial shunt type at the Norwood operation impacts myocardial function in hypoplastic left heart syndrome.

    PubMed

    Ruotsalainen, Hanna K; Pihkala, Jaana; Salminen, Jukka; Hornberger, Lisa K; Sairanen, Heikki; Ojala, Tiina

    2017-08-01

    We investigated the impact of initial shunt type, a Blalock-Taussig (BT) shunt versus a right ventricle to pulmonary artery conduit (RV-PA) on myocardial function at different stages of surgical palliation in patients with hypoplastic left heart syndrome (HLHS). A population-based cohort of 63 Finnish children with HLHS (BT n  = 23, RV-PA n  = 40) born between 2003 and 2010 were studied retrospectively by echocardiography prior to Stages 1, 2 and 3 palliation and 0.5-3 years after Stage 3. For comparison of systolic myocardial function, we evaluated the RV fractional area change (FAC), strain, strain rate and mechanical synchrony from the apical 4-chamber view by velocity vector imaging. There were no intergroup differences in demographics during the study period. At baseline, no intergroup differences were detected in RV systolic myocardial function. Before Stage 2, RV FAC was higher ( P  = 0.03) in the RV-PA conduit group. At Stage 3, an increase in all systolic myocardial functional parameters was observed in the BT shunt group. After Stage 3, the BT shunt group had better RV systolic function. In multiple regression analysis, the shunt type and the stage of palliation had an impact on myocardial function. Although patients with HLHS initially palliated with a BT shunt demonstrate lower RV FAC after Stage I, RV FAC improves after Stage 2 with better systolic performance after Stage 3 compared with those initially palliated with an RV-PA conduit. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Chatter reduction in boring process by using piezoelectric shunt damping with experimental verification

    NASA Astrophysics Data System (ADS)

    Yigit, Ufuk; Cigeroglu, Ender; Budak, Erhan

    2017-09-01

    Chatter is a self-excited type of vibration that develops during machining due to process-structure dynamic interactions resulting in modulated chip thickness. Chatter is an important problem as it results in poor surface quality, reduced productivity and tool life. The stability of a cutting process is strongly influenced by the frequency response function (FRF) at the cutting point. In this study, the effect of piezoelectric shunt damping on chatter vibrations in a boring process is studied. In piezoelectric shunt damping method, an electrical impedance is connected to a piezoelectric transducer which is bonded on cutting tool. Electrical impedance of the circuit consisting of piezoceramic transducer and passive shunt is tuned to the desired natural frequency of the cutting tool in order to maximize damping. The optimum damping is achieved in analytical and finite element models (FEM) by using a genetic algorithm focusing on the real part of the tool point FRF rather than the amplitude. Later, a practical boring bar is considered where the optimum circuit parameters are obtained by the FEM. Afterwards, the effect of the optimized piezoelectric shunt damping on the dynamic rigidity and absolute stability limit of the cutting process are investigated experimentally by modal analysis and cutting tests. It is both theoretically and experimentally shown that application of piezoelectric shunt damping results in a significant increase in the absolute stability limit in boring operations.

  20. The value of temporary external lumbar CSF drainage in predicting the outcome of shunting on normal pressure hydrocephalus

    PubMed Central

    Walchenbach, R; Geiger, E; Thomeer, R; Vanneste, J

    2002-01-01

    Objective: It has been reported that temporary external lumbar CSF drainage (ELD) is a very accurate test for predicting the outcome after ventricular shunting in patients with normal pressure hydrocephalus (NPH). However, only a limited number of patients have been studied for assessing the predictive accuracy of ELD. Therefore, the value of ELD in predicting the outcome after a ventriculoperitoneal shunt in patients with presumed NPH was assessed. Methods: All patients with presumed NPH were invited to participate in this study. Clinical assessment, MRI, and neuropsychological evaluation were followed by a lumbar CSF tap test consisting of removing 40 ml CSF. When this test resulted in marked clinical improvement of gait impairment, mental disturbances, or both, the patient was shunted without further tests. In patients with either questionable or no improvement after the CSF tap test, ELD was carried out. The value of ELD for predicting the outcome after shunting was calculated by correlating the results of ELD with that of ventriculoperitoneal shunting. Results: Between January 1994 and December 2000, 49 presumed NPH patients from three institutes were included. Forty three had idiopathic, and the remaining six had secondary NPH. Forty eight patients were shunted; 39 had an ELD of whom 38 completed the test. After 2 months 35 of the 48 (73%) shunted patients had improved. The predictive value of a positive ELD was 87% (95% confidence interval (95% CI) 62–98) and that of a negative ELD 36% (95% CI 17–59). In two patients serious test related complications (meningitis) occurred without residual deficit. Conclusion: The study suggests that although the predictive value of a positive ELD is high, that of a negative ELD is deceptively low because of the high rate of false negative results. The costs and invasiveness of the test and the possibility of serious test related complications further limits its usefulness in managing patients with presumed NPH. PMID:11909911

  1. Progressive Functional Underdrainage in Cerebrospinal Fluid Shunt-Dependent Women During Pregnancy: Case Report and Review of the Literature.

    PubMed

    Krauss, Philipp; Fritz-Naville, Marco; Regli, Luca; Stieglitz, Lennart Henning

    2018-01-01

    Since the 1950s cerebrospinal fluid (CSF) shunt dependency has no longer been a contradiction to normal life, including sexuality and pregnancy in women, because of advances in the understanding of hydrocephalus and shunt technology. Although pregnancy in shunt-dependent women is rare, it causes uncertainty among treating physicians. We report the case of a 34-year-old pregnant woman with a ventriculoperitoneal shunt. Throughout her pregnancy she experienced progressive symptoms of CSF underdrainage without any signs of other pregnancy-related complications. After the delivery of a healthy infant, shunt resistance had to be readjusted to prepregnancy levels. A comprehensive review of the literature reports in English, listed in PubMed, is provided. Conservative treatment of pregnancy-related functional underdrainage by consecutive valve pressure adjustment is possible, easy, and safe. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Should ventriculoatrial shunting be the procedure of choice for normal-pressure hydrocephalus?

    PubMed

    McGovern, Robert A; Kelly, Kathleen M; Chan, Andrew K; Morrissey, Nicholas J; McKhann, Guy M

    2014-06-01

    Ventriculoatrial (VA) shunting is rarely used for patients with normal-pressure hydrocephalus (NPH), likely due to surgeon technical preference and case reports indicating cardiopulmonary complications. However, these complications have typically been limited to adults in whom VA shunts had been placed when they were children. Few studies have directly compared VA shunting to ventriculoperitoneal (VP) shunting in cases of NPH. The authors retrospectively analyzed all NPH patients treated by a single surgeon at their center from January 2002 through December 2011. Thirty patients were treated with VA shunts (14 male) and 157 with VP shunts (86 male). The patients' mean age (± SD) at surgery was 73.7 ± 9.4 years for VA shunting and 76.0 ± 8.2 years for VP shunting; the median durations of follow-up were 42.0 months (IQR 19.2-63.6 months) and 34.2 months (IQR 15.8-67.5), respectively. Statistical analysis was performed using chi-square tests and Wilcoxon rank-sum tests. Perioperative and postoperative complications for VA and VP shunting cohorts, respectively, included distal revision (2.7% vs 6.6%, p = 0.45), proximal revision (2.7% vs 2.5%, p = 0.97), and postoperative seizure (2.7% vs 1.5%, p = 0.62). Shunt drainage-related subdural hematomas/hygromas developed in 8.1%/27.0% of VA shunt-treated patients versus 6.6%/26.4% of VP shunt-treated patients (p = 0.76/0.98) and were nearly always successfully managed with programmable-valve adjustment. Symptomatic intracerebral hemorrhage (1.5%) and shunt infection (2.0%) were only observed in those who underwent VP shunting. Of note, no cardiovascular complications were observed in any patient, and there were no cases of distal occlusion of the VA shunt. The authors found no significant differences in complication rates between VA and VP shunting, and VA shunting was not associated with any cardiopulmonary complications. Thus, in the authors' experience, VA shunting is at least as safe as VP shunting for treating NPH.

  3. Cerebrospinal Fluid Lumbar Tapping Utilization for Suspected Ventriculoperitoneal Shunt Under-Drainage Malfunctions

    PubMed Central

    Lee, Jong-Beom; Ahn, Ho-Young; Lee, Hong-Jae; Yang, Ji-Ho; Yi, Jin-Seok; Lee, Il-Woo

    2017-01-01

    Objective The diagnosis of shunt malfunction can be challenging since neuroimaging results are not always correlated with clinical outcomes. The purpose of this study was to evaluate the efficacy of a simple, minimally invasive cerebrospinal fluid (CSF) lumbar tapping test that predicts shunt under-drainage in hydrocephalus patients. Methods We retrospectively reviewed the clinical and radiological features of 48 patients who underwent routine CSF lumbar tapping after ventriculoperitoneal shunt (VPS) operation using a programmable shunting device. We compared shunt valve opening pressure and CSF lumbar tapping pressure to check under-drainage. Results The mean pressure difference between valve opening pressure and CSF lumbar tapping pressure of all patients were 2.21±24.57 mmH2O. The frequency of CSF lumbar tapping was 2.06±1.26 times. Eighty five times lumbar tapping of 41 patients showed that their VPS function was normal which was consistent with clinical improvement and decreased ventricle size on computed tomography scan. The mean pressure difference in these patients was −3.69±19.20 mmH2O. The mean frequency of CSF lumbar tapping was 2.07±1.25 times. Fourteen cases of 10 patients revealed suspected VPS malfunction which were consistent with radiological results and clinical symptoms, defined as changes in ventricle size and no clinical improvement. The mean pressure difference was 38.07±23.58 mmH2O. The mean frequency of CSF lumbar tapping was 1.44±1.01 times. Pressure difference greater than 35 mmH2O was shown in 2.35% of the normal VPS function group (2 of 85) whereas it was shown in 64.29% of the suspected VPS malfunction group (9 of 14). The difference was statistically significant (p=0.000001). Among 10 patients with under-drainage, 5 patients underwent shunt revision. The causes of the shunt malfunction included 3 cases of proximal occlusion and 2 cases of distal obstruction and valve malfunction. Conclusion Under-drainage of CSF should be suspected if CSF lumbar tapping pressure is 35 mmH2O higher than the valve opening pressure and shunt malfunction evaluation or adjustment of the valve opening pressure should be made. PMID:28061484

  4. Shunting normal pressure hydrocephalus: the predictive value of combined clinical and CT data.

    PubMed

    Vanneste, J; Augustijn, P; Tan, W F; Dirven, C

    1993-03-01

    The value of an ordinal global scale derived from combined clinical and CT data (clin/CT scale) to predict the clinical outcome in 112 patients shunted for presumed normal pressure hydrocephalus (NPH) was analysed. The clinical data were retrospectively collected, all CT scans were re-evaluated, and the clin/CT scale was determined blind to the results of further ancillary tests and to the post-surgical outcome. The scale ranked three classes of prediction: on the basis of clinical and CT characteristics, improvement after shunting was probable, possible, or improbable. The predictive value of the clin/CT scale for the subgroup of communicating NPH was established for two different strategies, depending on the strictness of selection criteria for shunting. In the subgroup of patients with presumed communicating NPH, the prevalence of shunt responsiveness was 29%; the best strategy was to shunt only patients with probable shunt-responsive NPH: the sensitivity was 0.54, the specificity 0.84, and the predictive accuracy 0.75, with a limited number of ineffective shunts (11%) and missed improvements (13%). The study illustrates its need to assess the pre-test probability of NPH based on combined clinical and CT data, before establishing the clinical usefulness of an ancillary test.

  5. Shunting normal pressure hydrocephalus: the predictive value of combined clinical and CT data.

    PubMed Central

    Vanneste, J; Augustijn, P; Tan, W F; Dirven, C

    1993-01-01

    The value of an ordinal global scale derived from combined clinical and CT data (clin/CT scale) to predict the clinical outcome in 112 patients shunted for presumed normal pressure hydrocephalus (NPH) was analysed. The clinical data were retrospectively collected, all CT scans were re-evaluated, and the clin/CT scale was determined blind to the results of further ancillary tests and to the post-surgical outcome. The scale ranked three classes of prediction: on the basis of clinical and CT characteristics, improvement after shunting was probable, possible, or improbable. The predictive value of the clin/CT scale for the subgroup of communicating NPH was established for two different strategies, depending on the strictness of selection criteria for shunting. In the subgroup of patients with presumed communicating NPH, the prevalence of shunt responsiveness was 29%; the best strategy was to shunt only patients with probable shunt-responsive NPH: the sensitivity was 0.54, the specificity 0.84, and the predictive accuracy 0.75, with a limited number of ineffective shunts (11%) and missed improvements (13%). The study illustrates its need to assess the pre-test probability of NPH based on combined clinical and CT data, before establishing the clinical usefulness of an ancillary test. PMID:8459240

  6. Protection relay of phase-shifting device with thyristor switch for high voltage power transmission lines

    NASA Astrophysics Data System (ADS)

    Lachugin, V. F.; Panfilov, D. I.; Akhmetov, I. M.; Astashev, M. G.; Shevelev, A. V.

    2014-12-01

    Problems of functioning of differential current protection systems of phase shifting devices (PSD) with mechanically changed coefficient of transformation of shunt transformer are analyzed. Requirements for devices of protection of PSD with thyristor switch are formulated. Based on use of nonlinear models of series-wound and shunt transformers of PSD modes of operation of major protection during PSD, switching to zero load operation and to operation under load and during short circuit operation were studied for testing PSD with failures. Use of the principle of duplicating by devices of differential current protection (with realization of functions of breaking) of failures of separate pares of PSD with thyristor switch was substantiated. To ensure protection sensitivity to the shunt transformer winding short circuit, in particular, to a short circuit that is not implemented in the current differential protection for PSD with mechanical switch, the differential current protection reacting to the amount of primary ampere-turns of high-voltage and low-voltage winding of this transformer was designed. Studies have shown that the use of differential current cutoff instead of overcurrent protection for the shunt transformer wndings allows one to provide the sensitivity during thyristor failure with the formation of a short circuit. The results of simulation mode for the PSD with switch thyristor designed to be installed as switching point of Voskhod-Tatarskaya-Barabinsk 220 kV transmission line point out the efficiency of the developed solutions that ensure reliable functioning of the PSD.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu Jing; Rovey, Joshua L.

    A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 {Omega} characteristic impedance to match with 50 {Omega} standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fallmore » time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a ''double-humped'' energy distribution.« less

  8. The classification based on intrahepatic portal system for congenital portosystemic shunts.

    PubMed

    Kanazawa, Hiroyuki; Nosaka, Shunsuke; Miyazaki, Osamu; Sakamoto, Seisuke; Fukuda, Akinari; Shigeta, Takanobu; Nakazawa, Atsuko; Kasahara, Mureo

    2015-04-01

    Liver transplantation was previously indicated as a curative operation for congenital absence of portal vein. Recent advances in radiological interventional techniques can precisely visualize the architecture of the intrahepatic portal system (IHPS). Therefore, the therapeutic approach for congenital portosystemic shunt (CPS) needs to be reevaluated from a viewpoint of radiological appearances. The aim of this study was to propose the IHPS classification which could explain the pathophysiological characteristics and play a complementary role of a therapeutic approach and management for CPS. Nineteen patients with CPS were retrospectively reviewed. The median age at diagnosis was 6.8 years old. Eighteen of these patients underwent angiography with a shunt occlusion test and were classified based of the severity of the hypoplasia of IHPS. The eighteen cases who could undergo the shunt occlusion test were classified into mild (n=7), moderate (n=6) and severe types (n=5) according to the IHPS classification. The IHPS classification correlated with the portal venous pressure under shunt occlusion, the histopathological findings, postoperative portal venous flow and liver regeneration. Shunt closure resulted in dramatic improvement in the laboratory data and subclinical encephalopathy. Two patients with the severe type suffered from sepsis associated with portal hypertension after treatment, and from the portal flow steal phenomenon because of the development of unexpected collateral vessels. The patients with the severe type had a high risk of postoperative complications after shunt closure in one step, even if the PVP was relatively low during the shunt occlusion test. The IHPS could be visualized by the shunt occlusion test. The IHPS classification reflected the clinicopathological features of CPS, and was useful to determine the therapeutic approach and management for CPS. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Risk factors for stent graft thrombosis after transjugular intrahepatic portosystemic shunt creation.

    PubMed

    Jahangiri, Younes; Kerrigan, Timothy; Li, Lei; Prosser, Dominik; Brar, Anantnoor; Righetti, Johnathan; Schenning, Ryan C; Kaufman, John A; Farsad, Khashayar

    2017-12-01

    To identify risk factors of stent graft thrombosis after transjugular intrahepatic portosystemic shunt (TIPS) creation. Patients who underwent TIPS creation between June 2003 and January 2016 and with follow-up assessing stent graft patency were included (n=174). Baseline comorbidities, liver function, procedural details and follow-up liver function tests were analyzed in association with hazards of thrombosis on follow-up. Competing risk cox regression models were used considering liver transplant after TIPS creation as the competing risk variable. One-, 2- and 5-year primary patency rates were 94.1%, 91.7% and 78.2%, respectively. Patient age [sub-hazard ratio (sHR): 1.13; P=0.001], body mass index (BMI) <30 (sHR: 33.08; P=0.008) and a higher post-TIPS portosystemic pressure gradient (sHR: 1.14; P=0.023) were significantly associated with TIPS thrombosis in multivariate analysis. A higher rate of TIPS thrombosis was observed in those for whom the procedure was clinically unsuccessful (P=0.014). A significant increase in incidence of thrombosis was noted with increasing tertiles of post-TIPS portosystemic gradients (P value for trend=0.017). Older age, lower BMI and higher post-TIPS portosystemic gradients were associated with higher hazards of shunt thrombosis after TIPS creation using stent grafts. Higher rates of shunt thrombosis were seen in patients for whom TIPS creation was clinically unsuccessful. The association between TIPS thrombosis and higher post-TIPS portosystemic gradients may indicate impaired flow through the shunt, a finding which may be technical or anatomic in nature and should be assessed before procedure completion.

  10. Physiological differences between various types of Eisenmenger syndrome and relation to outcome.

    PubMed

    Moceri, Pamela; Kempny, Aleksander; Liodakis, Emmanouil; Alonso Gonzales, Rafael; Germanakis, Ioannis; Diller, Gerhard-Paul; Swan, Lorna; Marino, Philip S; Wort, Stephen J; Babu-Narayan, Sonya V; Ferrari, Emile; Gatzoulis, Michael A; Li, Wei; Dimopoulos, Konstantinos

    2015-01-20

    Eisenmenger syndrome (ES) is the most advanced form of pulmonary arterial hypertension (PAH) related to congenital heart disease. Several studies have suggested that the presence and location of the shunt defines the natural history of these patients by influencing right ventricular adaptation to PAH. We aimed to echocardiographically assess differences in cardiac physiology and outcome between various types of ES. In this longitudinal cohort study, 191 patients with ES and non-complex congenital heart disease were recruited, 36 with pre-tricuspid and 155 with post-tricuspid shunts. Patients with pre-tricuspid shunts were older, had higher BNP concentrations and lower exercise tolerance compared to patients with post-tricuspid shunts. Right ventricular (RV) function was impaired in patients with atrial septal defects, with larger right ventricles, impaired systolic function and adaptation. The left ventricular eccentricity index was significantly higher in pre-tricuspid defects. Within post-tricuspid shunts, patients with atrio-ventricular septal defects had better right ventricular function compared to ventricular septal defects, while in those with a patent ductus arteriosus this was worse. There was a trend towards lower mortality in patients with post versus pre-tricuspid shunts, which was significant for patients above the age of 48 years. The presence of a post-tricuspid shunt appears to carry physiological and possibly prognostic benefits in ES compared to patients with pre-tricuspid shunts. This should be borne in mind when management decisions and advanced therapies are considered. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  11. 21 CFR 876.5955 - Peritoneo-venous shunt.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Identification. A peritoneo-venous shunt is an implanted device that consists of a catheter and a pressure...) Backflow specification and testing to prevent reflux of blood into the shunt. [48 FR 53023, Nov. 23, 1983...

  12. 21 CFR 876.5955 - Peritoneo-venous shunt.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) Identification. A peritoneo-venous shunt is an implanted device that consists of a catheter and a pressure...) Backflow specification and testing to prevent reflux of blood into the shunt. [48 FR 53023, Nov. 23, 1983...

  13. 21 CFR 876.5955 - Peritoneo-venous shunt.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Identification. A peritoneo-venous shunt is an implanted device that consists of a catheter and a pressure...) Backflow specification and testing to prevent reflux of blood into the shunt. [48 FR 53023, Nov. 23, 1983...

  14. 21 CFR 876.5955 - Peritoneo-venous shunt.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) Identification. A peritoneo-venous shunt is an implanted device that consists of a catheter and a pressure...) Backflow specification and testing to prevent reflux of blood into the shunt. [48 FR 53023, Nov. 23, 1983...

  15. 21 CFR 876.5955 - Peritoneo-venous shunt.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Identification. A peritoneo-venous shunt is an implanted device that consists of a catheter and a pressure...) Backflow specification and testing to prevent reflux of blood into the shunt. [48 FR 53023, Nov. 23, 1983...

  16. Cerebrospinal fluid pulse pressure amplitude during lumbar infusion in idiopathic normal pressure hydrocephalus can predict response to shunting

    PubMed Central

    2010-01-01

    Background We have previously seen that idiopathic normal pressure hydrocephalus (iNPH) patients having elevated intracranial pressure (ICP) pulse amplitude consistently respond to shunt surgery. In this study we explored how the cerebrospinal fluid pressure (CSFP) pulse amplitude determined during lumbar infusion testing, correlates with ICP pulse amplitude determined during over-night ICP monitoring and with response to shunt surgery. Our goal was to establish a more reliable screening procedure for selecting iNPH patients for shunt surgery using lumbar intrathecal infusion. Methods The study population consisted of all iNPH patients undergoing both diagnostic lumbar infusion testing and continuous over-night ICP monitoring during the period 2002-2007. The severity of iNPH was assessed using our NPH grading scale before surgery and 12 months after shunting. The CSFP pulse was characterized from the amplitude of single pressure waves. Results Totally 62 iNPH patients were included, 45 of them underwent shunt surgery, in whom 78% were shunt responders. Among the 45 shunted patients, resistance to CSF outflow (Rout) was elevated (≥ 12 mmHg/ml/min) in 44. The ICP pulse amplitude recorded over-night was elevated (i.e. mean ICP wave amplitude ≥ 4 mmHg) in 68% of patients; 92% of these were shunt responders. In those with elevated overnight ICP pulse amplitude, we found also elevated CSFP pulse amplitude recorded during lumbar infusion testing, both during the opening phase following lumbar puncture and during a standardized period of lumbar infusion (15 ml Ringer over 10 min). The clinical response to shunting after 1 year strongly associated with the over-night ICP pulse amplitude, and also with the pulsatile CSFP during the period of lumbar infusion. Elevated CSFP pulse amplitude during lumbar infusion thus predicted shunt response with sensitivity of 88 and specificity of 60 (positive and negative predictive values of 89 and 60, respectively). Conclusions In iNPH patients, shunt response can be anticipated in 9/10 patients with elevated overnight ICP pulse amplitude, while in only 1/10 with low ICP pulse amplitude. Additionally, the CSFP pulse amplitude during lumbar infusion testing was elevated in patients with elevated over-night ICP pulse amplitude. In particular, measurement of CSFP pulse amplitude during a standardized infusion of 15 ml Ringer over 10 min was useful in predicting response to shunt surgery and can be used as a screening procedure for selection of iNPH patients for shunting. PMID:20205911

  17. Use of programmable versus nonprogrammable shunts in the management of hydrocephalus secondary to aneurysmal subarachnoid hemorrhage: a retrospective study with cost-benefit analysis.

    PubMed

    Lee, Lester; King, Nicolas K K; Kumar, Dinesh; Ng, Yew Poh; Rao, Jai; Ng, Huiyu; Lee, Kah Keow; Wang, Ernest; Ng, Ivan

    2014-10-01

    The choice of programmable or nonprogrammable shunts for the management of hydrocephalus after aneurysmal subarachnoid hemorrhage (SAH) remains undefined. Variable intracranial pressures make optimal management difficult. Programmable shunts have been shown to reduce problems with drainage, but at 3 times the cost of nonprogrammable shunts. All patients who underwent insertion of a ventriculoperitoneal shunt for hydrocephalus after aneurysmal SAH between 2006 and 2012 were included. Patients were divided into those in whom nonprogrammable shunts and those in whom programmable shunts were inserted. The rates of shunt revisions, the reasons for adjustments of shunt settings in patients with programmable devices, and the effectiveness of the adjustments were analyzed. A cost-benefit analysis was also conducted to determine if the overall cost for programmable shunts was more than for nonprogrammable shunts. Ninety-four patients underwent insertion of shunts for hydrocephalus secondary to SAH. In 37 of these patients, nonprogrammable shunts were inserted, whereas in 57 programmable shunts were inserted. Four (7%) of 57 patients with programmable devices underwent shunt revision, whereas 8 (21.6%) of 37 patients with nonprogrammable shunts underwent shunt revision (p = 0.0413), and 4 of these patients had programmable shunts inserted during shunt revision. In 33 of 57 patients with programmable shunts, adjustments were made. The adjustments were for a trial of functional improvement (n = 21), overdrainage (n = 5), underdrainage (n = 6), or overly sunken skull defect (n = 1). Of these 33 patients, 24 showed neurological improvements (p = 0.012). Cost-benefit analysis showed $646.60 savings (US dollars) per patient if programmable shunts were used, because the cost of shunt revision is a lot higher than the cost of the shunt. The rate of shunt revision is lower in patients with programmable devices, and these are therefore more cost-effective. In addition, the shunt adjustments made for patients with programmable devices also resulted in better neurological outcomes.

  18. Comparative durability and costs analysis of ventricular shunts.

    PubMed

    Agarwal, Nitin; Kashkoush, Ahmed; McDowell, Michael M; Lariviere, William R; Ismail, Naveed; Friedlander, Robert M

    2018-05-11

    OBJECTIVE Ventricular shunt (VS) durability has been well studied in the pediatric population and in patients with normal pressure hydrocephalus; however, further evaluation in a more heterogeneous adult population is needed. This study aims to evaluate the effect of diagnosis and valve type-fixed versus programmable-on shunt durability and cost for placement of shunts in adult patients. METHODS The authors retrospectively reviewed the medical records of all patients who underwent implantation of a VS for hydrocephalus at their institution over a 3-year period between August 2013 and October 2016 with a minimum postoperative follow-up of 6 months. The primary outcome was shunt revision, which was defined as reoperation for any indication after the initial procedure. Supply costs, shunt durability, and hydrocephalus etiologies were compared between fixed and programmable valves. RESULTS A total of 417 patients underwent shunt placement during the index time frame, consisting of 62 fixed shunts (15%) and 355 programmable shunts (85%). The mean follow-up was 30 ± 12 (SD) months. The shunt revision rate was 22% for programmable pressure valves and 21% for fixed pressure valves (HR 1.1 [95% CI 0.6-1.8]). Shunt complications, such as valve failure, infection, and overdrainage, occurred with similar frequency across valve types. Kaplan-Meier survival curve analysis showed no difference in durability between fixed (mean 39 months) and programmable (mean 40 months) shunts (p = 0.980, log-rank test). The median shunt supply cost per index case and accounting for subsequent revisions was $3438 (interquartile range $2938-$3876) and $1504 (interquartile range $753-$1584) for programmable and fixed shunts, respectively (p < 0.001, Wilcoxon rank-sum test). Of all hydrocephalus etiologies, pseudotumor cerebri (HR 1.9 [95% CI 1.2-3.1]) and previous shunt malfunction (HR 1.8 [95% CI 1.2-2.7]) were found to significantly increase the risk of shunt revision. Within each diagnosis, there were no significant differences in revision rates between shunts with a fixed valve and shunts with a programmable valve. CONCLUSIONS Long-term shunt revision rates are similar for fixed and programmable shunt pressure valves in adult patients. Hydrocephalus etiology may play a significant role in predicting shunt revision, although programmable valves incur higher supply costs regardless of initial diagnosis. Utilization of fixed pressure valves versus programmable pressure valves may reduce supply costs while maintaining similar revision rates. Given the importance of developing cost-effective management protocols, this study highlights the critical need for large-scale prospective observational studies and randomized clinical trials of ventricular shunt valve revisions and additional patient-centered outcomes.

  19. Patients with a Normal Pressure Hydrocephalus Shunt Have Fewer Complications than Do Patients with Other Shunts.

    PubMed

    Schenker, Pascale; Stieglitz, Lennart H; Sick, Beate; Stienen, Martin N; Regli, Luca; Sarnthein, Johannes

    2018-02-01

    Ventriculoperitoneal (VP) shunting is a well-established therapy for hydrocephalus. However, complications are frequent. The incidence of idiopathic normal pressure hydrocephalus (NPH) increases with the aging of the population. We evaluated the functional status of patients and the classification of complications associated with VP shunt procedures in our center. We recorded all VP shunt procedures in our prospective patient registry from January 2013 to December 2015. Functional outcome (Karnofsky Performance Status [KPS] and modified Rankin Scale) and complications were compiled from patient records. Any deviation from the normal postoperative course within 3 months after surgery was considered a complication. Complications were classified with the therapy-oriented Clavien-Dindo grading system. We evaluated potential risk factors with a logistic regression model. From 285 procedures in the reporting period, 90 were excluded, resulting in 195 patients. Among those patients, 174 (90%) were shunt implantations and 21 (11%) were shunt revisions. Forty-four shunts (23%) were implanted for NPH. Median KPS improved over the first year after surgery. Although some type of complication was observed in 114 patients (58%), 60 of those complications (31%) did not require surgical treatment (Clavien-Dindo grade <3). In 50 patients (26%), the complication concerned the shunt itself. A high KPS at admission and NPH as underlying indication significantly reduced the odds ratio for a complication. Although shunt surgery has a high general rate of complications, this rate is significantly lower for patients with NPH. The decision for shunting in patients with NPH should consider the low complication rate specific for the group of patients with NPH. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Comparative performance analysis of shunt and series passive filter for LED lamp

    NASA Astrophysics Data System (ADS)

    Sarwono, Edi; Facta, Mochammad; Handoko, Susatyo

    2018-03-01

    Light Emitting Diode lamp or LED lamp nowadays is widely used by consumers as a new innovation in the lighting technologies due to its energy saving for low power consumption lamps for brighter light intensity. How ever, the LED lamp produce an electric pollutant known as harmonics. The harmonics is generated by rectifier as part of LED lamp circuit. The present of harmonics in current or voltage has made the source waveform from the grid is distorted. This distortion may cause inacurrate measurement, mall function, and excessive heating for any element at the grid. This paper present an analysis work of shunt and series filters to suppress the harmonics generated by the LED lamp circuit. The work was initiated by conducting several tests to investigate the harmonic content of voltage and currents. The measurements in this work were carried out by using HIOKI Power Quality Analyzer 3197. The measurement results showed that the harmonics current of tested LED lamps were above the limit of IEEE standard 519-2014. Based on the measurement results shunt and series filters were constructed as low pass filters. The bode analysis were appled during construction and prediction of the filters performance. Based on experimental results, the application of shunt filter at input side of LED lamp has reduced THD current up to 88%. On the other hand, the series filter has significantly reduced THD current up to 92%.

  1. The importance of valve alignment in determining the pressure/flow characteristics of differential pressure shunt valves with anti-gravity devices.

    PubMed

    Francel, P C; Stevens, F A; Tompkins, P; Pollay, M

    2001-02-01

    The proper functioning of shunt valves in vivo is dependent on many factors, including the valve itself, the anti-siphon device or ASD (if included), patency of inlet and outlet tubing, and location of the valve. One important, but sometimes overlooked, consideration in valve function is the valve location relative to the tip of the ventricular inlet catheter. As with any pressure measurement, the zero or reference position is an important concept. In the case of shunt valves, the position of the proximal inlet catheter tip is fixed and therefore serves as the reference point for all pressure measurements. This study was conducted to document the importance of this relationship for the pressure/flow characteristics of the shunt valve. We bench-tested differential pressure valves (with integral anti-gravity devices; AGDs) from three manufacturers. Valves were connected to an "infinite" reservoir, and the starting head pressure for each was determined from product inserts. The inlet catheter tip was fixed at this position, and the valve body was moved in relation to the inlet catheter tip. Outflow rates were determined gravimetrically for positions varying between 4 cm above and 8 cm below the inlet catheter tip. All differential pressure valves utilized in this study that contained AGDs showed significant increases in outflow rate as the valve body was moved incrementally below the level of the inlet catheter tip. To allow functioning as a zero-hydrostatic pressure differential pressure valve, the AGD and the inlet catheter tip should be aligned at the same horizontal level.

  2. Hydrodynamics of the Certas™ programmable valve for the treatment of hydrocephalus

    PubMed Central

    2012-01-01

    Background The new Certas™ shunt for the treatment of hydrocephalus has seven standard pressure settings that according to the manufacturer range from 36 to 238 mmH2O, and an additional “Virtual Off” setting with an opening pressure >400 mmH2O. Information on actual pressure response and reliability of shunt performance is important in clinical application, especially the “Virtual Off” setting as a non-surgical replacement for shunt ligation. The objective of this study was to evaluate the in-vitro hydrodynamic performance of the Certas™ shunt. Methods Six new Certas™ shunts with proximal and distal catheters were tested with an automated, computerized test system that raised the pressure from zero to a maximum pressure and back to zero at each valve setting. Opening pressure and flow resistance were determined. Results For settings 1–7 the measured opening pressure range was 26 to 247 mmH2O, and the mean change in opening pressure for a one-step adjustment was between 33 and 38 mmH2O. For setting 8 (“Virtual Off”) the measured mean opening pressure was 494 ± 34 mmH2O (range 451 to 556 mmH2O). The mean outflow resistance was 7.0 mmHg/ml/min (outflow conductance 17.9 μl/s/kPa). Conclusions The six shunts had similar characteristics and closely matched the manufacturer’s specifications for opening pressure at settings 1–7. The opening pressure for the “Virtual Off” setting was nearly 500 mmH2O, which is 100 mmH2O higher than the manufacturer’s specification of “>400” and should be functionally off for most patients with communicating hydrocephalus. Clinical studies are needed to evaluate if the CSF dynamic profile persists after implantation in patients. PMID:22643114

  3. Risk factors for stent graft thrombosis after transjugular intrahepatic portosystemic shunt creation

    PubMed Central

    Jahangiri, Younes; Kerrigan, Timothy; Li, Lei; Prosser, Dominik; Brar, Anantnoor; Righetti, Johnathan; Schenning, Ryan C.; Kaufman, John A.

    2017-01-01

    Background To identify risk factors of stent graft thrombosis after transjugular intrahepatic portosystemic shunt (TIPS) creation. Methods Patients who underwent TIPS creation between June 2003 and January 2016 and with follow-up assessing stent graft patency were included (n=174). Baseline comorbidities, liver function, procedural details and follow-up liver function tests were analyzed in association with hazards of thrombosis on follow-up. Competing risk cox regression models were used considering liver transplant after TIPS creation as the competing risk variable. Results One-, 2- and 5-year primary patency rates were 94.1%, 91.7% and 78.2%, respectively. Patient age [sub-hazard ratio (sHR): 1.13; P=0.001], body mass index (BMI) <30 (sHR: 33.08; P=0.008) and a higher post-TIPS portosystemic pressure gradient (sHR: 1.14; P=0.023) were significantly associated with TIPS thrombosis in multivariate analysis. A higher rate of TIPS thrombosis was observed in those for whom the procedure was clinically unsuccessful (P=0.014). A significant increase in incidence of thrombosis was noted with increasing tertiles of post-TIPS portosystemic gradients (P value for trend=0.017). Conclusions Older age, lower BMI and higher post-TIPS portosystemic gradients were associated with higher hazards of shunt thrombosis after TIPS creation using stent grafts. Higher rates of shunt thrombosis were seen in patients for whom TIPS creation was clinically unsuccessful. The association between TIPS thrombosis and higher post-TIPS portosystemic gradients may indicate impaired flow through the shunt, a finding which may be technical or anatomic in nature and should be assessed before procedure completion. PMID:29399518

  4. Reversible CSF cyst related to a functioning ventriculo-peritoneal shunt.

    PubMed

    Vajramani, G V; Fugleholm, K

    2005-11-01

    Although the occurrence of CSF oedema and cyst has been described in presence of a blocked ventriculoperitoneal shunt, especially distal end block, its occurrence in presence of a well functioning shunt has not been described so far. We report a case where a 51-year old lady developed an insidious onset and gradually progressive CSF cyst without any clinical or radiological feature of shunt block over a period of about 2 years. The changes started about 6 months after a course of radiation therapy for an extensive residual supra and infratentorial meningioma. Following surgery, where the cyst was punctured and a new ventricular catheter was inserted, despite well functioning upper and lower end, the cyst gradually disappeared. We review the literature and hypothesize that the radiation-induced changes were responsible for initiation and progression of the cyst.

  5. Potential use of metabolic breath tests to assess liver disease and prognosis: has the time arrived for routine use in the clinic?

    PubMed

    Stravitz, R Todd; Ilan, Yaron

    2017-03-01

    The progression of liver disease may be unique among organ system diseases in that progressive fibrosis compromises not only the sufficiency of hepatocyte mass but also impairs blood flow to the liver, resulting in porto-systemic shunting. Although liver biopsy as an assessment of fibrosis has become the key biomarker of and target for new therapies, it is invasive and subject to sampling error, and cannot quantify metabolic function or porto-systemic shunting. Measurement of the hepatic venous pressure gradient accommodates some of the deficiencies of biopsy but requires expertise not widely available and misses minor changes in hepatocellular mass and thereby information about metabolic function. Thus, an unmet need in clinical hepatology remains unfulfilled: a noninvasive biomarker which quantitates both the hepatocellular insufficiency and porto-systemic shunting inherent in progressive hepatic fibrosis. Ideally, such a biomarker should correlate with clinical endpoints including liver-related survival and cirrhotic complications, be performed at the point-of-care, and be affordable and easy to use. This review, an expert opinion, summarizes background and recent data suggesting that metabolic breath tests may now meet these requirements and have a valid place in clinical hepatology to supplant the time-honoured assessment of hepatic fibrosis. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization.

    PubMed

    Hu, Jing; Rovey, Joshua L

    2011-07-01

    A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 Ω characteristic impedance to match with 50 Ω standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a "double-humped" energy distribution.

  7. Temporary arterial shunts to maintain limb perfusion after arterial injury: an animal study

    NASA Technical Reports Server (NTRS)

    Dawson, D. L.; Putnam, A. T.; Light, J. T.; Ihnat, D. M.; Kissinger, D. P.; Rasmussen, T. E.; Bradley, D. V. Jr

    1999-01-01

    BACKGROUND: Temporary shunt placement can quickly restore perfusion after extremity arterial injury. This study examined the adequacy of limb blood flow with shunt use, non-heparin-bonded shunt patency over prolonged periods, and the safety of this technique. METHODS: Common iliac arteries were divided and 4.0-mm Silastic Sundt shunts placed in 16 anesthetized pigs. Eight (group I) had shunts placed immediately; eight others (group II) were shunted after an hour of limb ischemia and hemorrhagic shock. Physiologic parameters and femoral artery blood flow in both hindlimbs were continuously monitored. Limb lactic acid generation, oxygen utilization, and hematologic and metabolic effects were serially evaluated for 24 hours. RESULTS: Shunts remained patent in 13 of 16 pigs. Shunts thrombosed in two group I animals because of technical errors, but functioned well after thrombectomy and repositioning. Patency could not be maintained in one animal that died from shock. Flow in group I shunted limbs was 57 (+/-11 SD) % of control. For group II animals in shock, shunted limb flow initially averaged 46 +/- 15% of control, but 4 hours after shunt placement, the mean limb blood flow was the same as in group I. Increased oxygen extraction compensated for the lower flow. Lactic acid production was not increased in comparison to control limbs. CONCLUSION: Shunts provided adequate flow in this model of extremity trauma. Correctly placed shunts stayed patent for 24 hours, without anticoagulation, if shunt placement followed resuscitation.

  8. Surgical approach for systemic-pulmonary shunt in neonates with functionally univentricular heart: comparison between sternotomy and thoracotomy.

    PubMed

    Sasaki, Takashi; Takeda, Yuko; Ohnakatomi, Yasuko; Asou, Toshihide

    2016-09-01

    The preferred surgical approach for systemic-pulmonary shunts has changed from thoracotomy to sternotomy in our institution, to concomitantly manage the ductus arteriosus during surgery. The purpose of this study was to compare the outcomes of systemic-pulmonary shunts for neonates with functionally univentricular hearts based on surgical approach. Fifty-two neonates with functionally univentricular hearts underwent systemic-pulmonary shunt via sternotomy (n = 28) or thoracotomy (n = 24). Patient characteristics, achievement rates of right heart bypass, and survival rates were compared for the different approaches. Prenatal diagnosis was made more common in the sternotomy group (p = 0.006). The shunt was placed more centrally in the sternotomy group. The ductus arteriosus was ligated or banded in most patients in the sternotomy group (26/28) and in a few patients in the thoracotomy group (6/24). Frequency of ductal management in the early postoperative phase was not different between the groups (21 vs 25 %), but three new incisions had to be made in the thoracotomy group. No differences were seen in the achievement rates of bidirectional cavopulmonary shunts (86 vs 87 % at 10 months of age) and total cavopulmonary connection (81 vs 81 % at 2 years of age), or in the survival rates (92 vs 96 % at 8 years). There were no differences in short- and long-term outcomes between the groups. The sternotomy approach might be preferable in the current era of prenatal diagnosis, to allow simultaneous duct management during systemic-pulmonary shunt surgery, particularly in patients with large ducts associated with functionally univentricular hearts.

  9. Hydrocephalus shunt technology: 20 years of experience from the Cambridge Shunt Evaluation Laboratory.

    PubMed

    Chari, Aswin; Czosnyka, Marek; Richards, Hugh K; Pickard, John D; Czosnyka, Zofia H

    2014-03-01

    The Cambridge Shunt Evaluation Laboratory was established 20 years ago. This paper summarizes the findings of that laboratory for the clinician. Twenty-six models of valves have been tested long-term in the shunt laboratory according to the expanded International Organization for Standardization 7197 standard protocol. The majority of the valves had a nonphysiologically low hydrodynamic resistance (from 1.5 to 3 mm Hg/[ml/min]), which may result in overdrainage related to posture and during nocturnal cerebral vasogenic waves. A long distal catheter increases the resistance of these valves by 100%-200%. Drainage through valves without a siphon-preventing mechanism is very sensitive to body posture, which may result in grossly negative intracranial pressure. Siphon-preventing accessories offer a reasonable resistance to negative outlet pressure; however, accessories with membrane devices may be blocked by raised subcutaneous pressure. In adjustable valves, the settings may be changed by external magnetic fields of intensity above 40 mT (exceptions: ProGAV, Polaris, and Certas). Most of the magnetically adjustable valves produce large distortions on MRI studies. The behavior of a valve revealed during testing is of relevance to the surgeon and may not be adequately described in the manufacturer's product information. The results of shunt testing are helpful in many circumstances, such as the initial choice of shunt and the evaluation of the shunt when its dysfunction is suspected.

  10. Superconducting quantum interference device with frequency-dependent damping: Readout of flux qubits

    NASA Astrophysics Data System (ADS)

    Robertson, T. L.; Plourde, B. L. T.; Hime, T.; Linzen, S.; Reichardt, P. A.; Wilhelm, F. K.; Clarke, John

    2005-07-01

    Recent experiments on superconducting flux qubits, consisting of a superconducting loop interrupted by Josephson junctions, have demonstrated quantum coherence between two different quantum states. The state of the qubit is measured with a superconducting quantum interference device (SQUID). Such measurements require the SQUID to have high resolution while exerting minimal backaction on the qubit. By designing shunts across the SQUID junctions appropriately, one can improve the measurement resolution without increasing the backaction significantly. Using a path-integral approach to analyze the Caldeira-Leggett model, we calculate the narrowing of the distribution of the switching events from the zero-voltage state of the SQUID for arbitrary shunt admittances, focusing on shunts consisting of a capacitance Cs and resistance Rs in series. To test this model, we fabricated a dc SQUID in which each junction is shunted with a thin-film interdigitated capacitor in series with a resistor, and measured the switching distribution as a function of temperature and applied magnetic flux. After accounting for the damping due to the SQUID leads, we found good agreement between the measured escape rates and the predictions of our model. We analyze the backaction of a shunted symmetric SQUID on a flux qubit. For the given parameters of our SQUID and realistic parameters for a flux qubit, at the degeneracy point we find a relaxation time of 113μs , which limits the decoherence time to 226μs . Based on our analysis of the escape process, we determine that a SQUID with purely capacitive shunts should have narrow switching distributions and no dissipation.

  11. Cross-Species Functionality of Pararetroviral Elements Driving Ribosome Shunting

    PubMed Central

    Pooggin, Mikhail M.; Fütterer, Johannes; Hohn, Thomas

    2008-01-01

    Background Cauliflower mosaic virus (CaMV) and Rice tungro bacilliform virus (RTBV) belong to distinct genera of pararetroviruses infecting dicot and monocot plants, respectively. In both viruses, polycistronic translation of pregenomic (pg) RNA is initiated by shunting ribosomes that bypass a large region of the pgRNA leader with several short (s)ORFs and a stable stem-loop structure. The shunt requires translation of a 5′-proximal sORF terminating near the stem. In CaMV, mutations knocking out this sORF nearly abolish shunting and virus viability. Methodology/Principal Findings Here we show that two distant regions of the CaMV leader that form a minimal shunt configuration comprising the sORF, a bottom part of the stem, and a shunt landing sequence can be replaced by heterologous sequences that form a structurally similar configuration in RTBV without any dramatic effect on shunt-mediated translation and CaMV infectivity. The CaMV-RTBV chimeric leader sequence was largely stable over five viral passages in turnip plants: a few alterations that did eventually occur in the virus progenies are indicative of fine tuning of the chimeric sequence during adaptation to a new host. Conclusions/Significance Our findings demonstrate cross-species functionality of pararetroviral cis-elements driving ribosome shunting and evolutionary conservation of the shunt mechanism. We are grateful to Matthias Müller and Sandra Pauli for technical assistance. This work was initiated at Friedrich Miescher Institute (Basel, Switzerland). We thank Prof. Thomas Boller for hosting the group at the Institute of Botany. PMID:18286203

  12. Shunted Piezoelectric Vibration Damping Analysis Including Centrifugal Loading Effects

    NASA Technical Reports Server (NTRS)

    Min, James B.; Duffy, Kirsten P.; Provenza, Andrew J.

    2011-01-01

    Excessive vibration of turbomachinery blades causes high cycle fatigue problems which require damping treatments to mitigate vibration levels. One method is the use of piezoelectric materials as passive or active dampers. Based on the technical challenges and requirements learned from previous turbomachinery rotor blades research, an effort has been made to investigate the effectiveness of a shunted piezoelectric for the turbomachinery rotor blades vibration control, specifically for a condition with centrifugal rotation. While ample research has been performed on the use of a piezoelectric material with electric circuits to attempt to control the structural vibration damping, very little study has been done regarding rotational effects. The present study attempts to fill this void. Specifically, the objectives of this study are: (a) to create and analyze finite element models for harmonic forced response vibration analysis coupled with shunted piezoelectric circuits for engine blade operational conditions, (b) to validate the experimental test approaches with numerical results and vice versa, and (c) to establish a numerical modeling capability for vibration control using shunted piezoelectric circuits under rotation. Study has focused on a resonant damping control using shunted piezoelectric patches on plate specimens. Tests and analyses were performed for both non-spinning and spinning conditions. The finite element (FE) shunted piezoelectric circuit damping simulations were performed using the ANSYS Multiphysics code for the resistive and inductive circuit piezoelectric simulations of both conditions. The FE results showed a good correlation with experimental test results. Tests and analyses of shunted piezoelectric damping control, demonstrating with plate specimens, show a great potential to reduce blade vibrations under centrifugal loading.

  13. Do antibiotic-impregnated shunts in hydrocephalus therapy reduce the risk of infection? An observational study in 258 patients

    PubMed Central

    Ritz, Rainer; Roser, Florian; Morgalla, Matthias; Dietz, Klaus; Tatagiba, Marcos; Will, Bernd E

    2007-01-01

    Background Shunt infection in hydrocephalus patients is a severe, even life-threatening complication. Antibiotic-impregnated shunts (AIS) have been developed in an attempt to reduce rate of shunt infection. The study was performed to analyze if AIS can diminish the rate of shunt infection. The pathogenic nature of shunt infection in patients with AIS systems and those without antibiotic impregnated shunts (non-AIS) was compared. Methods Over a period of 24 months in the Department of Neurosurgery at University Hospital of Tübingen shunt surgery was performed in 258 patients. In 86 patients AIS systems were implanted. Shunt catheters were commercially impregnated with clindamycin and rifampicin. Analysis of the clinical data included sex, age, classification of hydrocephalus, shunt types and risk factors for shunt infection [age (< 1 year and > 80 years), prematurely born patients, external ventricular drainage, former shunt infection, former systemic infection, disturbance of consciousness, former radiation-/chemotherapy]. Infection rates and underlying bacterial pathogens of patients with AIS were compared to patients with implanted non-AIS systems (172 patients). Results AIS and non-AIS patients did not differ in sex, etiology of hydrocephalus and the shunt type. In the AIS group 72 out of 86 patients had at least one risk factor (83.7 %), compared to 126 patients in the non-AIS group (73.3 %). There was no significant difference between the two groups (p = 0.0629; Fisher's exact test). In patients with no risk factors, only one patient with non-AIS suffered from shunt infection. In patients with one or more risk factors the rate for shunt infection was 7.14 % in patients with non-AIS and 6.94 % in patients with AIS. Former shunt infection (p = 0.0124) was related to higher risk for shunt infection. The use of AIS had therefore no significant advantage (p = 0.8611; multiple logistic regression). Significantly related to a shunt infection was the number of shunt surgeries. 190 interventions in the AIS group (2.21 interventions per patient) and 408 in the non-AIS group (2.37 interventions per patient) had been performed (p = 0.3063; Wilcoxon). There was no shunt infection in the group of patients on whom only one shunt surgery was performed. In patients with at least two shunt surgeries the infection rate was 9%. The infection rate in AIS patients was 5/52 (9.6 %) and in the non-AIS 10/114 (8.77 %), (p = 1.0; Fisher's exact test). Staphylococcus epidermidis was the most frequent pathogen for shunt infection. Fourteen out of 15 infections occurred within the first 6 months of surgery. The most frequent pathogen for shunt infection was S. epidermidis. No toxic or allergic complications were seen using the AIS shunt systems. The presented data show a remarkably low infection rate of 5.8 % in the non-AIS group compared to other studies which demonstrated a significant decrease in the infection rate by AIS. Conclusion AIS did not significantly reduce shunt infection in hydrocephalus patients in the presented study. In the AIS group three patients suffered from shunt infections caused by skin ulceration or neurosurgical procedures with exposure of the cerebrospinal liquor after shunt implantation. AIS was not developed to prevent infection in such cases, therefore an advantage of AIS can not be excluded. In view of the presented data and the small number of reported studies a prospective randomized multicenter study is required. PMID:17488498

  14. Multi-resonant electromagnetic shunt in base isolation for vibration damping and energy harvesting

    NASA Astrophysics Data System (ADS)

    Pei, Yalu; Liu, Yilun; Zuo, Lei

    2018-06-01

    This paper investigates multi-resonant electromagnetic shunts applied to base isolation for dual-function vibration damping and energy harvesting. Two multi-mode shunt circuit configurations, namely parallel and series, are proposed and optimized based on the H2 criteria. The root-mean-square (RMS) value of the relative displacement between the base and the primary structure is minimized. Practically, this will improve the safety of base-isolated buildings subjected the broad bandwidth ground acceleration. Case studies of a base-isolated building are conducted in both the frequency and time domains to investigate the effectiveness of multi-resonant electromagnetic shunts under recorded earthquake signals. It shows that both multi-mode shunt circuits outperform traditional single mode shunt circuits by suppressing the first and the second vibration modes simultaneously. Moreover, for the same stiffness ratio, the parallel shunt circuit is more effective at harvesting energy and suppressing vibration, and can more robustly handle parameter mistuning than the series shunt circuit. Furthermore, this paper discusses experimental validation of the effectiveness of multi-resonant electromagnetic shunts for vibration damping and energy harvesting on a scaled-down base isolation system.

  15. [Selective portal-systemic shunts for bleeding portal hypertension].

    PubMed

    Orozco, H; Mercado, M A; Takahashi, T; García-Tsao, G; Guevara, L; Hernandez-Ortiz, J; Tielve, M

    1990-07-01

    At the beginning of the seventies, we began to perform regularly selective shunts for the treatment of portal hypertension. In a 15 year period, 177 patients (155 with liver cirrhosis) were operated with three kinds of selective shunts: 128 with a Warren shunt, 29 with an end to end renosplenic shunt and 20 with a splenocaval shunt. 167 cases were operated in an elective fashion. The 15 years global operative mortality, was 14.4%. Operative mortality of the Child A patients, was 11.6%. Survival for the Child A group was 74.6% at 1 year, 68.2% at 5 years and 64.6% at 15 years. Incapacitating encephalopathy was observed in 6.9%, rebleeding 6.2% and shunt thrombosis in 6.2%. Portal vein alterations in the postoperative period were observed: in 13.3% a reduction in diameter ocurred and in 20.5%, thrombosis was recorded. It is concluded that when feasible, the selective shunts are the treatment of choice for portal hypertension in those patients with good liver function.

  16. The Neuroimaging Studies in Children with Ventriculoperitoneal Shunt Complications: A 10 Years Descriptive Sudy in Tehran.

    PubMed

    Shahi, Mohammad Vafaee; Noorbakhsh, Samileh; Zarrabi, Vida; Nourozi, Banafsheh; Tahernia, Leila

    2018-01-01

    Any mismatch between the production and absorption of CSF results in hydrocephalus. In most cases, the selected choice of treatment is the ventriculoperitoneal shunt insertion. Although, the surgery could have complications such as infection, shunt malfunction, subdural hematoma, seizure and Shunt immigration; so, the early and proper detection of these complications could result in better prognosis. The aim of this study was to evaluate and compare the efficacy of CT scan, CSF analysis and X-ray radiography in detection of shunt complications and problems in shunt placement and further follow-up in hospitalized children. The medical records of children in Rasul Akram hospital in Tehran were reviewed retrospectively in the last 10 years, from 2006 to 2016. All data were recorded in the prepared form including the age, sex, shunt complication, CT scan and CSF characteristics. The total number of 95 patients were interfered in this study including 56 males (58.9%) and 39 females (41.1%). The mean age at the onset of complications were 2.8±2.2 years-old. The shunt obstruction (60%) and infection (25.3%) were the most common complications. The CT scan was able to detect 36.5% of shunt complications. The CT scan had the sensitivity and specificity of 50 and 87%, respectively in detection of shunt obstruction. The all cases of brain hematoma and hemorrhage were revealed by CT scan. On the other hand, the CT scan had 20% of sensitivity and 60% of specificity in the detection of shunt infection. The CSF evaluation in shunt infection revealed 92% hypoglycemia, 87.5% pleocytosis, and 62.5% positive CSF culture. CSF had the sensitivity, specificity, positive predictive value and negative predictive value of 92, 82, 63 and 97%, respectively. The patient's symptoms and signs were helpful in obtaining higher test accuracy. The CT scan was not a good sensitive and specific study in the detection of shunt obstruction and infection, but it was very accurate in detection of hemorrhage and hematoma. On the other hand, CSF evaluation was a reliable test in shunt infection disclosure.

  17. What is the risk of infecting a cerebrospinal fluid-diverting shunt with percutaneous tapping?

    PubMed

    Spiegelman, Lindsey; Asija, Richa; Da Silva, Stephanie L; Krieger, Mark D; McComb, J Gordon

    2014-10-01

    Most CSF-diverting shunt systems have an access port that can be percutaneously tapped. Tapping the shunt can yield valuable information as to its function and whether an infection is present. The fear of causing a shunt infection by tapping may limit the physician's willingness to do so. The authors of this study investigate the risk of infecting a shunt secondary to percutaneous tapping. Following institutional review board approval, CSF specimens obtained from tapping an indwelling CSF-diverting shunt during the 2011 and 2012 calendar years were identified and matched with clinical information. A culture-positive CSF sample was defined as an infection. If results were equivocal, such as a broth-only-positive culture, a repeat CSF specimen was examined. The CSF was obtained by tapping the shunt access port with a 25-gauge butterfly needle after prepping the unshaven skin with chlorhexidine. During the study period, 266 children underwent 542 shunt taps. With 541 taps, no clinical evidence of a subsequent shunt infection was found. One child's CSF went from sterile to infected 11 days later; however, this patient had redness along the shunt tract at the time of the initial sterile tap. The risk of infection from tapping a shunt is remote if the procedure is done correctly.

  18. Long-term outcomes of kidney and bladder function in patients with a posterior urethral valve.

    PubMed

    Kim, Sung Jin; Jung, Jaeyoon; Lee, Chanwoo; Park, Sejun; Song, Sang Hoon; Won, Hye-Sung; Kim, Kun Suk

    2018-06-01

    We investigated long-term functional changes in the kidney and bladder of patients with posterior urethral valve (PUV) who underwent fetal intervention or postnatal surgery.We retrospectively reviewed the medical records of 28 consecutive patients treated for PUV at our institution. Detailed data on medical and surgical histories, particularly on pre- and postnatal treatment modality, including fetal vesicoamniotic shunt, endoscopic valve ablation, and vesicostomy, were collected and analyzed. Long-term renal function was evaluated based on serum levels of creatinine (sCr), estimated glomerular filtration rate (eGFR), and renal scans. Voiding function was evaluated in urodynamic tests.Vesicoamniotic shunting was performed in 12 (42.8%) patients. Although the mean initial sCr was significantly higher in patients in whom a fetal shunt was placed than in others (2.04 vs 1.17 mg/L, P = .038), the sCr at long-term follow-up was not significantly different between them (0.64 vs 0.40 mg/L, P = .186). The mean maximum detrusor pressure was significantly lower in patients with a fetal shunt than in others (37.7 vs 73.0 cm H2O, P = .019). Postnatal vesicostomy was performed in 14 patients, and primary valve ablation was performed in 13 patients. The mean initial sCr was higher in patients in the vesicostomy group than in the primary valve ablation group (2.08 vs 0.86 mg/L, P = .014). However, no significant differences were found in sCr (0.9 vs 0.3 mg/L, P = .252) or GFR (59.1 vs 68.5 mL/min/1.73 m, P = .338) at long-term follow-up. Bladder capacity was greater and residual urine volume was less in the vesicostomy group than in the primary valve ablation group, but without statistical significance.Vesicostomy is more beneficial in the recovery of renal function and is not inferior in terms of bladder function, even in patients with severe PUV disorder. It is a reliable surgical option that can spare renal function and guarantee adequate bladder function in the long term.

  19. New and improved ways to treat hydrocephalus: Pursuit of a smart shunt.

    PubMed

    Lutz, Barry R; Venkataraman, Pranav; Browd, Samuel R

    2013-01-01

    The most common treatment for hydrocephalus is placement of a cerebrospinal fluid shunt to supplement or replace lost drainage capacity. Shunts are life-saving devices but are notorious for high failure rates, difficulty of diagnosing failure, and limited control options. Shunt designs have changed little since their introduction in 1950s, and the few changes introduced have had little to no impact on these long-standing problems. For decades, the community has envisioned a "smart shunt" that could provide advanced control, diagnostics, and communication based on implanted sensors, feedback control, and telemetry. The most emphasized contribution of smart shunts is the potential for advanced control algorithms, such as weaning from shunt dependency and personalized control. With sensor-based control comes the opportunity to provide data to the physician on patient condition and shunt function, perhaps even by a smart phone. An often ignored but highly valuable contribution would be designs that correct the high failure rates of existing shunts. Despite the long history and increasing development activity in the past decade, patients are yet to see a commercialized smart shunt. Most smart shunt development focuses on concepts or on isolated technical features, but successful smart shunt designs will be a balance between technical feasibility, economic viability, and acceptable regulatory risk. Here, we present the status of this effort and a framework for understanding the challenges and opportunities that will guide introduction of smart shunts into patient care.

  20. Idiopathic normal pressure hydrocephalus: the CSF tap-test may predict the clinical response to shunting.

    PubMed

    Sand, T; Bovim, G; Grimse, R; Myhr, G; Helde, G; Cappelen, J

    1994-05-01

    A follow-up study was performed in nine patients with idiopathic normal pressure hydrocephalus (NPH) 37 months (mean) after shunting and 10 non-operated controls with comparable degrees of ventricular enlargement, gait disorder, and dementia. Five operated patients vs. no controls reported sustained general improvement (p < 0.02). Objectively improved gait at follow-up (compared with preoperative status) was found in five of the six tested NPH-patients vs. none of the controls (p < 0.005). Improved gait and/or psychometric function was found in four of six NPH vs. none of eight control patients (p < 0.02) after drainage of 40 ml cerebrospinal fluid (CSF tap-test). Improved gait during the CSF tap-test predicted continued improvement at follow-up. Temporal horn size was the only radiological variable which showed a (moderate) positive correlation with resistance to CSF absorption and rate of pressure increase. The size of the third ventricle diminished in parallel with clinical improvement.

  1. An Approach to Endovascular and Percutaneous Management of Transjugular Intrahepatic Portosystemic Shunt (TIPS) Dysfunction: A Pictorial Essay and Clinical Practice Algorithm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pereira, Keith, E-mail: keithjppereira@gmail.com; Baker, Reginald, E-mail: rbaker@med.miami.edu; Salsamendi, Jason

    Transjugular intrahepatic portosystemic shunts (TIPS) have evolved as an effective and durable nonsurgical option in the treatment of portal hypertension (PH). It has been shown to improve survival in decompensated cirrhosis and may also serve as a bridge to liver transplantation. In spite of the technical improvements in the procedure, problems occur with the shunt which jeopardizes effective treatment of the PH. Appropriate management is vital to ensure the longevity of the conduit. Shunt revision techniques include endovascular revision techniques and new shunt creation or, in the appropriate patients, alternative/rescue therapies. The ability of interventional radiologists to restore adequate TIPSmore » function has enormous implications for quality of life with palliation, morbidity/mortality related to variceal bleeding and survival if transplant candidates can live long enough to receive a new liver. As such, it is imperative that these treatment strategies are understood and employed when these patients are encountered. In this review, the restoration of appropriate shunt function using various techniques will be discussed as they apply to a variety of clinical scenarios, based on literature. In addition, illustrative case examples highlighting our experience at an academic tertiary medical center will be included. It is the intent to have this document serve as a concise and informative reference to be used by those who may encounter patients with suboptimal functioning TIPS.« less

  2. An Approach to Endovascular and Percutaneous Management of Transjugular Intrahepatic Portosystemic Shunt (TIPS) Dysfunction: A Pictorial Essay and Clinical Practice Algorithm.

    PubMed

    Pereira, Keith; Baker, Reginald; Salsamendi, Jason; Doshi, Mehul; Kably, Issam; Bhatia, Shivank

    2016-05-01

    Transjugular intrahepatic portosystemic shunts (TIPS) have evolved as an effective and durable nonsurgical option in the treatment of portal hypertension (PH). It has been shown to improve survival in decompensated cirrhosis and may also serve as a bridge to liver transplantation. In spite of the technical improvements in the procedure, problems occur with the shunt which jeopardizes effective treatment of the PH. Appropriate management is vital to ensure the longevity of the conduit. Shunt revision techniques include endovascular revision techniques and new shunt creation or, in the appropriate patients, alternative/rescue therapies. The ability of interventional radiologists to restore adequate TIPS function has enormous implications for quality of life with palliation, morbidity/mortality related to variceal bleeding and survival if transplant candidates can live long enough to receive a new liver. As such, it is imperative that these treatment strategies are understood and employed when these patients are encountered. In this review, the restoration of appropriate shunt function using various techniques will be discussed as they apply to a variety of clinical scenarios, based on literature. In addition, illustrative case examples highlighting our experience at an academic tertiary medical center will be included. It is the intent to have this document serve as a concise and informative reference to be used by those who may encounter patients with suboptimal functioning TIPS.

  3. [Surgery in portal hypertension. Which patient and which operation?].

    PubMed

    Mercado, M A; Takahashi, T; Rojas, G; Prado, E; Hernández, J; Tielve, M; Orozco, H

    1993-01-01

    A prospective trial of a cohort of patients (N = 94) with portal hypertension and history of bleeding was selected for surgery based on strict clinical and laboratory criteria. All of them were treated with portal blood flow preserving procedures. The following selection criteria were used: good cardiopulmonary function without pulmonary hypertension and good liver function (Child-Pugh A). All patients were operated in an elective fashion and the operations performed were: selective shunts (N = 38) (distal splenorenal and splenocaval), low diameter mesocaval shunts (N = 13) and the esophagogastric devascularization with esophageal transection (Sugiura-Futagawa) (N = 43). Patients were selected for each operation according to their anatomical conditions. Sixty-one of the patients were cirrhotics. Operative mortality was 8% and rebleeding was observed in 5% of the cases. Postoperative encephalopathy was seen in seven patients (three selective shunts, two low diameter mesocaval shunts and two devascularizations). In 13 of 62 patients postoperatively evaluated by means of angiography, portal vein thrombosis was shown (seven selective shunts, two low diameter shunts and four devascularizations). Twenty-two patients with preoperative portal vein thrombosis (and treated with a Sugiura-Futagawa operation) were excluded from postoperative angiographic evaluation. Survival (Kaplan-Meier) was 85% at 60 months. Portal blood flow preserving procedures are the treatment of choice for patients with hemorrhagic portal hypertension and good liver function. The kind of operation is selected according to the individual anatomical status of the patient.

  4. Daily tadalafil for the chronic phase of stuttering priapism: a case report.

    PubMed

    Massenio, Paolo; D'Altilia, Nicola; Sanguedolce, Francesca; Carrieri, Giuseppe; Cormio, Luigi

    2018-05-31

    Recurrent (stuttering) ischemic priapism is a challenging clinical condition. Frequent recurrences result in frequent hospital admissions whereas treatment with a shunting procedure often results in erectile dysfunction. A 22-year-old man with stuttering idiopathic priapism developed erectile dysfunction (IIEF-5 score 12) following a Winter's shunt; he was given tadalafil, 5 mg/daily, for 6 months. This treatment resulted in progressive restoration of erectile function in the 6 months following the shunt as well as in preventing recurrence of priapic episodes over a 24-month follow-up. This is the first report in literature of chronic treatment of stuttering priapism with a phosphodiesterase-5 inhibitor being able not only to prevent recurrent priapic episodes but also to restore erectile function following a Winter's shunt.

  5. Pulse amplitude of intracranial pressure waveform in hydrocephalus.

    PubMed

    Czosnyka, Z; Keong, N; Kim, D J; Radolovich, D; Smielewski, P; Lavinio, A; Schmidt, E A; Momjian, S; Owler, B; Pickard, J D; Czosnyka, M

    2008-01-01

    There is increasing interest in evaluation of the pulse amplitude of intracranial pressure (AMP) in explaining dynamic aspects of hydrocephalus. We reviewed a large number of ICP recordings in a group of hydrocephalic patients to assess utility of AMP. From a database including approximately 2,100 cases of infusion studies (either lumbar or intraventricular) and overnight ICP monitoring in patients suffering from hydrocephalus of various types (both communicating and non-communicating), etiology and stage of management (non-shunted or shunted) pressure recordings were evaluated. For subgroup analysis we selected 60 patients with idiopathic NPH with full follow-up after shunting. In 29 patients we compared pulse amplitude during an infusion study performed before and after shunting with a properly functioning shunt. Amplitude was calculated from ICP waveforms using spectral analysis methodology. A large amplitude was associated with good outcome after shunting (positive predictive value of clinical improvement for AMP above 2.5 mmHg was 95%). However, low amplitude did not predict poor outcome (for AMP below 2.5 mmHg 52% of patients improved). Correlations of AMP with ICP and Rcsf were positive and statistically significant (N = 131 with idiopathic NPH; R = 0.21 for correlation with mean ICP and 0.22 with Rcsf; p< 0.01). Correlation with the brain elastance coefficient (or PVI) was not significant. There was also no significant correlation between pulse amplitude and width of the ventricles. The pulse amplitude decreased (p < 0.005) after shunting. Interpretation of the ICP pulse waveform may be clinically useful in patients suffering from hydrocephalus. Elevated amplitude seems to be a positive predictor for clinical improvement after shunting. A properly functioning shunt reduces the pulse amplitude.

  6. Pilot Comparisons of Temporary Open Revascularization Using Stent Grafts vs. Standard Shunts in a Sheep (Ovis aries) Model

    DTIC Science & Technology

    2016-03-14

    using stent grafts vs. standard shunts in a sheep (Ovis aries) model." PRINCIPAL INVESTIGATOR (Pl) I TRAINING COORDINATOR (TC): Lt Col James Sampson...Objectives: Pilot study and development of an experimental model to test and compare the performance of endovascular stent -graft as an arterial shunt...FDG2015001 OA 2 Results: Exposure and placement of vascular stent -grafts and shunts into the common carotid artery was feasible. Stent -graft and

  7. Serum hyaluronic acid in dogs with congenital portosystemic shunts.

    PubMed

    Seki, M; Asano, K; Sakai, M; Kanno, N; Teshima, K; Edamura, K; Tanaka, S

    2010-05-01

    To compare the serum level of hyaluronic acid in dogs with congenital portosystemic shunt with that in healthy dogs and to investigate the perioperative change in serum hyaluronic acid following shunt attenuation. Blood samples were obtained from 29 congenital portosystemic shunt dogs before the operation, and 2 and 4 weeks after the operation from 17 and 7 dogs, respectively. The serum hyaluronic acid level of these dogs was measured and compared with that of 10 healthy beagles. The median preoperative hyaluronic acid level in dogs with congenital portosystemic shunt was significantly elevated compared with that in healthy dogs. Furthermore, the median postoperative hyaluronic acid level significantly decreased compared with the median preoperative levels in congenital portosystemic shunt dogs. In the case of dogs with congenital portosystemic shunt, the reduction of intrahepatic portal blood flow might lower the clearance rate of hyaluronic acid in hepatic sinusoidal endothelial cells, so hyaluronic acid clearance could be improved by attenuation of a shunt vessel. Hence, serum hyaluronic acid levels might be useful to evaluate liver function and also have the potential to evaluate successful attenuation of a shunt vessel in dogs with congenital portosystemic shunt. Further investigations are required to clarify whether serum hyaluronic acid offers significant benefits over existing markers such as serum bile acid or ammonia concentrations.

  8. Conversion of Low-Flow Priapism to High-Flow State Using T-Shunt with Tunneling.

    PubMed

    Mistry, Neil A; Tadros, Nicholas N; Hedges, Jason C

    2017-01-01

    Introduction . The three types of priapism are stuttering, arterial (high-flow, nonischemic), and venoocclusive (low-flow, ischemic). These are usually distinct entities and rarely occur in the same patient. T-shunts and other distal shunts are frequently combined with tunneling, but a seldom recognized potential complication is conversion to a high-flow state. Case Presentation . We describe 2 cases of men who presented with low-flow priapism episodes that were treated using T-shunts with tunneling that resulted with both men having recurrent erections shortly after surgery that were found to be consistent with high-flow states. Case 1 was a 33-year-old male with sickle cell anemia and case 2 was a 24-year-old male with idiopathic thrombocytopenic purpura. In both cases the men were observed over several weeks and both men returned to normal erectile function. Conclusions . Historically, proximal shunts were performed only in cases when distal shunts failed and carry a higher risk of serious complications. T-shunts and other distal shunts combined with tunneling are being used more frequently in place of proximal shunts. These cases illustrate how postoperative erections after T-shunts with tunneling can signify a conversion from low-flow to high-flow states and could potentially be misdiagnosed as an operative failure.

  9. Hybrid approach to surgical correction of tetralogy of Fallot in all patients with functioning Blalock Taussig shunts.

    PubMed

    Sivakumar, Kothandam; Krishnan, Prasad; Pieris, Rajeeva; Francis, Edwin

    2007-08-01

    In total surgical correction of tetralogy of Fallot (TOF) with functioning Blalock Taussig shunts (BTS), shunt take down increased surgical time, bleeding, and might injure phrenic and recurrent laryngeal nerve and thoracic duct. A routine hybrid approach using transcatheter BTS closure immediately before total surgical correction of TOF in all patients might reduce these problems. We analyze the safety and feasibility of this approach. Transcatheter BTS closure was achieved using single or multiple stainless steel embolization coils, Amplatzer vascular plugs, or duct occluders. When coils were released without control by bioptome forceps, coil migration in larger shunts was prevented by proximal or distal balloon occlusion. This routine hybrid strategy was followed in 22 consecutive patients aged 1-13 years over 4-year-period and 21 procedures were successful. Among the 16 patients attempted with coils, 13 had successful closure, 2 needed Amplatzer duct occluder devices, and 1 sent for surgical shunt takedown due to acute angulation of the shunt. New Amplatzer vascular plugs were used in six patients. Bioptome was used in six patients and proximal or distal balloon occlusion of flow was used in three patients. Four patients had closure of associated aortopulmonary or chest wall collaterals. Hybrid approach using routine transcatheter closure of all BTS immediately before surgical correction of TOF shunts with coils/plugs/devices is safe, feasible, and reproducible. Copyright (c) 2007 Wiley-Liss, Inc.

  10. New and improved ways to treat hydrocephalus: Pursuit of a smart shunt

    PubMed Central

    Lutz, Barry R.; Venkataraman, Pranav; Browd, Samuel R.

    2013-01-01

    The most common treatment for hydrocephalus is placement of a cerebrospinal fluid shunt to supplement or replace lost drainage capacity. Shunts are life-saving devices but are notorious for high failure rates, difficulty of diagnosing failure, and limited control options. Shunt designs have changed little since their introduction in 1950s, and the few changes introduced have had little to no impact on these long-standing problems. For decades, the community has envisioned a “smart shunt” that could provide advanced control, diagnostics, and communication based on implanted sensors, feedback control, and telemetry. The most emphasized contribution of smart shunts is the potential for advanced control algorithms, such as weaning from shunt dependency and personalized control. With sensor-based control comes the opportunity to provide data to the physician on patient condition and shunt function, perhaps even by a smart phone. An often ignored but highly valuable contribution would be designs that correct the high failure rates of existing shunts. Despite the long history and increasing development activity in the past decade, patients are yet to see a commercialized smart shunt. Most smart shunt development focuses on concepts or on isolated technical features, but successful smart shunt designs will be a balance between technical feasibility, economic viability, and acceptable regulatory risk. Here, we present the status of this effort and a framework for understanding the challenges and opportunities that will guide introduction of smart shunts into patient care. PMID:23653889

  11. Multiple acquired portosystemic shunts secondary to primary hypoplasia of the portal vein in a cat.

    PubMed

    Sugimoto, Satoko; Maeda, Shingo; Tsuboi, Masaya; Saeki, Kohei; Chambers, James K; Yonezawa, Tomohiro; Fukushima, Kenjiro; Fujiwara, Reina; Uchida, Kazuyuki; Tsujimoto, Hajime; Matsuki, Naoaki; Ohno, Koichi

    2018-06-06

    A 6-year 5-month-old spayed female Scottish Fold cat presented with a one-month history of gait abnormalities, increased salivation, and decreased activity. A blood test showed hyperammonemia and increased serum bile acids. Imaging tests revealed multiple shunt vessels indicating acquired portosystemic shunt. Histopathologic analysis of liver biopsy showed features consistent with liver hypoperfusion, such as a barely recognizable portal vein, increased numbers of small arterioles, and diffuse vacuolar degeneration of hepatocytes. These findings supported the diagnosis of primary hypoplasia of the portal vein/microvascular dysplasia, (PHPV/MVD). To our knowledge, this is the first case of feline PHPV/MVD that developed multiple acquired portosystemic shunts and presented with hepatic encephalopathy.

  12. [Congenital portosystemic shunt. The Abernethy malformation].

    PubMed

    Avila, L F; Luis, A L; Encinas, J L; Hernández, F; Olivares, P; Fernández Cuadrado, J; Hierro, L; Jara, P; López Santamaría, M; Tovar, J A

    2006-10-01

    Congenital portosystemic shunt (CEPS) is a rare condition that was first reported by John Abernethy in 1793. Two types of CEPS are described: type I (side to end anastomosis) or congenital absence of the portal vein, and type II (side to side anastomosis) with portal vein supply partially conserved. Type I CEPS is usually seen in girls and associates multiple malformations as polysplenia, malrotation, and cardiac anomalies. Type II is even rarer with no sex preference and no malformations associated. Hepatic encephalopathy is a common complication of both types in adulthood. Liver transplantation is the only effective treatment for symptomatic type I CEPS. A therapeutic approach for type II could be surgical closure of the shunt. To analyse our experience in diagnosis and management of portosystemic shunts. We report 4 cases of CEPS (3 type I and 1 type II) diagnosed between January-1997 and March-2005 in our department. We present 4 patients with ages at diagnosis ranging from 0 to 28 months, 3 type I CEPS (2 boys and 1 girl) and 1 boy type II. The type I girl was prenatally diagnosed at 12 weeks of gestation. Initial clinical signs in type 1 boys were splenomegaly and hypersplenism, both with normal pondo-statural growth. No polysplenia or cardiac anomalies were assessed. One of them presented mild developmental delay, dismorphic features and facial telangiectasias. He had normal coagulation tests with chronic hepatic dysfunction (high transaminases) and regenerative nodular lesions were seen by imaging techniques. The other type I patient had hypoprothrombinemia, tendency to capillary bleeding (haematomas and epistaxis) with preserved liver function. Both patients have developed mild portal hypertension and present steatosis signs at liver biopsy. The type I girl presents a 21 trisomy and associates a cardiac anomaly (interauricular communication). Her hepatic function test are normal but liver calcifications can be seen by ultrasound. Type II child associates hypospadias but he has no clinical sigh or symptom related to the shunt. In our three cases diagnosis was suggested by conventional and Doppler ultrasound and confirmed by angio-resonance imaging. All our patients are included in a meticulous clinical and radiological follow-up with no need of surgical treatment for the shunt until now. Although diagnosis of these malformations could be casual we have to think about CEPS in children presenting unspecific liver disease. Magnetic angio-resonance imaging is actually the best diagnosis methods for CEPS. These patients have a high risk for developing hepatic encephalopathy and portal hypertension, so a careful follow-up is required although surgery is not usually needed until adulthood.

  13. Use of EOS Low-Dose Biplanar X-Ray for Shunt Series in Children with Hydrocephalus: A Preliminary Study.

    PubMed

    Ben-Sira, Liat; Shiran, Shelly I; Pratt, Li-Tal; Precel, Ronit; Ovadia, Dror; Constantini, Shlomi; Roth, Jonathan

    2018-05-04

    Shunt series (SS) are a common diagnostic tool used to verify shunt integrity. SS include X-ray films of the skull, chest, and abdomen and often are performed either when a shunted patient presents with suspected shunt malfunction or as a screening test to identify shunt disconnections or dislodgment. EOS low-dose biplanar X-rays are associated with significantly reduced radiation doses compared with ordinary X-rays and are used for various indications. This is the first publication on the use of EOS as a SS technique. Over a period of 6 months, EOS were performed at our center for various orthopedic indications, mostly for scoliosis evaluation. Nine children (<20 years of age) had a ventriculoperitoneal shunt and served as the study group. We retrospectively reviewed shunt visibility and integrity in the EOS scans as well as regular SS or plain spinal X-rays. Three patients had bilateral shunts, and 8 had previous X-rays for comparison. In all patients, the shunt integrity was easily demonstrated on the EOS images. Two patients had an identified shunt disconnection confirmed on the EOS images. No shunt-related information was missed on the EOS compared with the other X-ray images. These preliminary results suggest that EOS may be used as an alternative technology to demonstrate shunt integrity instead of regular X-ray SS. Favorable shunt visibility without the need for multiple radiation exposures and image processing (such as stitching) results in a significantly shorter examination time and significant less radiation. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Hepatopulmonary shunting on Tc99m-MAA liver mapping: correlation with dynamic cross-sectional imaging and description of different shunting patterns.

    PubMed

    Bermo, Mohammed; Matesan, Manuela C; Itani, Malak; Behnia, Fatemeh; Vesselle, Hubert J

    2018-04-09

    The purpose of the study was to correlate lung shunt fraction (LSF) calculated by intra-arterial injection of Technetium-99m (Tc-99m)-labeled macroaggregated albumin (MAA) in a hepatic artery branch with the presence of certain patterns of vascular shunts on dynamic CT or MRI of the liver. This retrospective study was approved by the institutional review board and informed consent was waived. We reviewed 523 MAA scans in 453 patients (301 men, 152 women) performed from July 2007 to June 2015 and their correlative cross-sectional imaging. Patterns of vascular shunts on dynamic CT or MRI performed within 3 months of the MAA study and that potentially divert hepatic arterial inflow to the systemic venous return were defined as "target shunts." Dynamic CT or MRI was classified into three groups with target shunt present, absent, or indeterminate. The mean LSF was compared across the first and second groups using paired t test. 342 CT and MRI studies met inclusion criteria: target shunts were present in 63 studies, absent in 271 studies, and 8 studies were indeterminate. When target shunts were visualized, the mean LSF on corresponding MAA scans was 12.9 ± 10.36% (95% CI 10.29-15.15%) compared to 4.3 ± 3.17% (95% CI 3.93-4.68%) when no target shunt was visualized. The difference was statistically significant (p value < 0.001). Identified target shunts were either direct (arteriohepatic venous shunt) or indirect (arterioportal shunt combined with a portosystemic shunt). Visualizing certain patterns of vascular shunting on a dynamic CT or MRI scan is associated with high LSF.

  15. Piezoelectric Shunt Vibration Damping of F-15 Panel under High Acoustic Excitation

    NASA Technical Reports Server (NTRS)

    Wu, Shu-Yau; Turner, Travis L.; Rizzi, Stephen A.

    2000-01-01

    At last year's SPIE symposium, we reported results of an experiment on structural vibration damping of an F-15 underbelly panel using piezoelectric shunting with five bonded PZT transducers. The panel vibration was induced with an acoustic speaker at an overall sound pressure level (OASPL) of about 90 dB. Amplitude reductions of 13.45 and 10.72 dB were achieved for the first and second modes, respectively, using single- and multiple-mode shunting. It is the purpose of this investigation to extend the passive piezoelectric shunt-damping technique to control structural vibration induced at higher acoustic excitation levels, and to examine the controllability and survivability of the bonded PZT transducers at these high levels. The shunting experiment was performed with the Thermal Acoustic Fatigue Apparatus (TAFA) at the NASA Langley Research Center using the same F-15 underbelly panel. The TAFA is a progressive wave tube facility. The panel was mounted in one wall of the TAFA test section using a specially designed mounting fixture such that the panel was subjected to grazing-incidence acoustic excitation. Five PZT transducers were used with two shunt circuits designed to control the first and second modes of the structure between 200 and 400 Hz. We first determined the values of the shunt inductance and resistance at an OASPL of 130 dB. These values were maintained while we gradually increased the OASPL from 130 to 154 dB in 6-dB steps. During each increment, the frequency response function between accelerometers on the panel and the acoustic excitation measured by microphones, before and after shunting, were recorded. Good response reduction was observed up to the 148dB level. The experiment was stopped at 154 dB due to wire breakage from vibration at a transducer wire joint. The PZT transducers, however, were still bonded well on the panel and survived at this high dB level. We also observed shifting of the frequency peaks toward lower frequency when the OASPL was increased. Detailed experimental results will be presented.

  16. Overdrainage and shunt technology. A critical comparison of programmable, hydrostatic and variable-resistance valves and flow-reducing devices.

    PubMed

    Aschoff, A; Kremer, P; Benesch, C; Fruh, K; Klank, A; Kunze, S

    1995-04-01

    When vertical body position is simulated, conventional differential pressure valves show an absolutely unphysiological flow, which is 2-170 times the normal liquor production rate. Although this is compensated in part by the resistance of the silicon tubes, which may produce up to 94% of the resistance of the complete shunt system, a negative intracranial pressure (ICP) of up to 30-44 cmH2O is an unavoidable consequence, which can be followed by subdural hematomas, slit ventricles, and other well-known complications. Modern shunt technology offers programmable, hydrostatic, and "flow-controlled" valves and anti-siphon devices; we have tested 13 different designs from 7 manufacturers (56 specimens), using the "Heidelberg Valve Test Inventory" with 16 subtests. "Programmable" valves reduce, but cannot exclude, unphysiological flow rates: even in the highest position and in combination with a standard catheter typical programmable Medos-Hakim valves allow a flow of 93-232 ml/h, Sophy SU-8-valves 86-168 ml/h with 30 cmH2O. The effect of hydrostatic valves (Hakim-Lumbar, Chhabra) can be inactivated by movements of daily life. The weight of the metal balls in most valves was too low for adequate flow reduction. Antisiphon devices are highly dependent on external, i.e. subcutaneous, pressure which has unpredictable influences on shunt function, and clinically is sometimes followed by shunt insufficiency. Two new Orbis-Sigma valves showed relatively physiological flow rates even when the vertical position (30 cmH2O) was simulated. One showed an insufficient flow (5.7 ml/h), and one was primarily obstructed. These have by far the smallest outlet of all valves. Additionally, the ruby pin tends to stick. Therefore, a high susceptibility to obliterations and blockade is unavoidable. Encouraging results obtained in pediatric patients contrast with disappointing experiences in some German and Swedish hospitals, which suggests that our laboratory findings are confirmed by clinical results. The concept of strict flow limitation seems to be inadaequate for adult patients, who need a relatively high flow during (nocturnal) ICP crises. The problem of shunt overdrainage remains unsolved.

  17. Long term results of balloon-occluded retrograde transvenous obliteration for portosystemic shunt encephalopathy in patients with liver cirrhosis and portal hypertension.

    PubMed

    Inoue, Hiroto; Emori, Keigo; Toyonaga, Atsushi; Oho, Kazuhiko; Kumamoto, Masafumi; Haruta, Tsuyoshi; Mitsuyama, Keiichi; Tsuruta, Osamu; Sata, Michio

    2014-01-01

    This study examined 19 patients with portosystemic shunt encephalopathy caused by a splenorenal shunt (SRS), which was treated with balloon-occluded retrograde transvenous obliteration (B-RTO). Long-term treatment outcomes were evaluated based on hepatic functional reserve and vital prognosis. Encephalopathy improved in all patients after shunt embolization and closure. Albumin, serum ammonia, and the Child-Pugh score, a measure of liver function, were significantly improved 3 years after B-RTO, and exacerbation of damage to liver function was avoided (p<0.01). During the follow-up period, three patients died from liver failure and two patients from hepatocellular carcinoma. Patients had a poor prognosis if their albumin levels were less than 2.8 mg / dL before B-RTO (p<0.05). Encephalopathy patients had complete response to B-RTO, but long-term prognosis was affected by hepatic functional reserve before B-RTO and by concurrent hepatocellular carcinoma. The results of this study suggest that in patients with SRS, it is important to perform B-RTO at an early stage when the hepatic functional reserve is still satisfactory.

  18. Living Donor Liver Transplantation Using a Liver Graft With Congenital Intrahepatic Portosystemic Shunt

    PubMed Central

    Kamei, Hideya; Imai, Hisashi; Onishi, Yasuharu; Sugimoto, Hiroyuki; Suzuki, Kojiro; Ogura, Yasuhiro

    2016-01-01

    Background Despite of recent development of imaging modalities, congenital intrahepatic portosystemic shunt (IPSS) is rarely diagnosed. Therefore, living donor liver transplantation using a liver graft with IPSS has not been previously published. Materials and Methods We report a 28-year-old male patient with end-stage liver disease secondary to Wilson disease. His 26-year-old brother was a potential living donor, who had an IPSS of 25 mm in diameter at segment 6 as shown by computed tomography. Liver function tests were normal, and blood ammonia concentration was in the upper limit of normal. Results Living donor liver transplantation was uneventfully performed. After surgery, a recipient liver function tests showed a quick recovery, and serum ammonia levels were consistently normal. Although thrombosis inside the IPSS was confirmed by computed tomography on postoperative day 21, this thrombosis disappeared at 3 months posttransplant with anticoagulants. Currently (12 months posttransplant), the patient has fully recovered, and the IPSS is still the same size. Conclusions Based on our experience, liver allografts with IPSS can be accepted as potential liver allografts. PMID:27500240

  19. Hepatocyte transplants improve liver function and encephalopathy in portacaval shunted rats.

    PubMed

    Fogel, Wieslawa Agnieszka; Stasiak, Anna; Maksymowicz, Michał; Kobos, Jozef; Unzeta, Mercedes; Mussur, Miroslaw

    2014-07-01

    Rats with portacaval shunt (PCS) are useful experimental models of human hepatic encephalopathy in chronic liver dysfunction. We have previously shown that PCS modifies amine neurotransmitter systems in the CNS and increases voluntary alcohol intake by rats. Hepatocyte transplantation, used in acute liver failure, has recently also been applied to chronic liver diseases, which prompted us to investigate whether the altered brain amine system and the drinking behavior in long-term shunted rats could be normalized by hepatocyte transplants. Hepatocytes, isolated from syngeneic donors by collagenase digestion, were injected (3 × 10(6) cells/rat) into the pancreatic tail region, 6 months after PCS. Hepatic function was evaluated by measuring urine urea and plasma L-histidine concentrations. A free choice test with two bottles (tap water and 10% ethyl alcohol) was performed for 3 days to assess the rats' preference for alcohol. The rats were euthanized 2 months posttransplantation. Brain histamine and 5-hydroxyindoleacetic acid (5-HIAA) levels were measured by radioenzymatic assay and by HPLC-EC, respectively, N-tele-methylhistamine by GC/MS while MAOA and MAOB activities by isotopic procedures. Portacaval shunt rats with hepatocyte transplants gave more urea than before transplantation, with lower plasma L-His levels and higher body weight versus the PCS counterparts. Also, those rats consumed less alcohol. The CNS amines and 5-HIAA concentrations, as well as MAO-B activity, being abnormally high in untreated PCS rats, significantly reduced after PCS hepatocyte treatment. The results support the therapeutic values of hepatocyte transplants in chronic liver diseases and the temporary character of PCS-exerted CNS dysfunctions. © 2014 John Wiley & Sons Ltd.

  20. Rate of shunt revision as a function of age in patients with shunted hydrocephalus due to myelomeningocele.

    PubMed

    Dupepe, Esther B; Hopson, Betsy; Johnston, James M; Rozzelle, Curtis J; Jerry Oakes, W; Blount, Jeffrey P; Rocque, Brandon G

    2016-11-01

    OBJECTIVE It is generally accepted that cerebrospinal fluid shunts fail most frequently in the first years of life. The purpose of this study was to describe the risk of shunt failure for a given patient age in a well-defined cohort with shunted hydrocephalus due to myelomeningocele (MMC). METHODS The authors analyzed data from their institutional spina bifida research database including all patients with MMC and shunted hydrocephalus. For the entire population, the number of shunt revisions in each year of life was determined. Then the number of patients at risk for shunt revision during each year of life was calculated, thus enabling them to calculate the rate of shunt revision per patient in each year of life. In this way, the timing of all shunt revision operations for the entire clinic population and the likelihood of having a shunt revision during each year of life were calculated. RESULTS A total of 655 patients were enrolled in the spina bifida research database, 519 of whom had a diagnosis of MMC and whose mean age was 17.48 ± 11.7 years (median 16 years, range 0-63 years). Four hundred seventeen patients had had a CSF shunt for the treatment of hydrocephalus and thus are included in this analysis. There were 94 shunt revisions in the 1st year of life, which represents a rate of 0.23 revisions per patient in that year. The rate of shunt revision per patient-year initially decreased as age increased, except for an increase in revision frequency in the early teen years. Shunt revisions continued to occur as late as 43 years of age. CONCLUSIONS These data substantiate the idea that shunt revision surgeries in patients with MMC are most common in the 1st year of life and decrease thereafter, except for an increase in the early teen years. A persistent risk of shunt failure was observed well into adult life. These findings underscore the importance of routine follow-up of all MMC patients with shunted hydrocephalus and will aid in counseling patients and families.

  1. Indications for endoscopic third ventriculostomy in normal pressure hydrocephalus.

    PubMed

    Paidakakos, Nikolaos; Borgarello, S; Naddeo, M

    2012-01-01

    Controversies remain regarding the proper diagnostic studies and prediction of outcome in patients with normal pressure hydrocephalus (NPH), and their management remains controversial. We propose a preoperative assessment routine the aim of which is to correctly select NPH patients, and to differentiate between them in terms of surgical treatment, identifying probable endoscopic third ventriculostomy (ETV) responders. We prospectively considered a group of 44 patients with suspected NPH on the basis of clinical symptoms and neuroradiological evidence, who have undergone supplemental diagnostic testing (tap test, external lumbar drainage, cerebrospinal fluid outflow resistance [Rout] determination through lumbar and ventricular infusion test). All 44 of these patients were treated with either shunt procedures or ETV. To choose the kind of treatment (shunt or ETV), we evaluated the individual response during infusion tests. The efficacy of both surgical techniques was approximately 70%, with a significantly lower complication rate for ETV. We evaluated the correlation between the various tests and the postoperative outcomes both for shunting and for ETV. Rout proved useful for preoperative assessment and choice of treatment. In carefully selected patients, ETV had qualitative results similar to shunting, presenting significantly fewer complications.

  2. Ion beam sputter-etched ventricular catheter for hydrocephalus shunt

    NASA Technical Reports Server (NTRS)

    Banks, B. A. (Inventor)

    1983-01-01

    A cerebrospinal fluid shunt in the form of a ventricular catheter for controlling the condition of hydrocephalus by relieving the excessive cerebrospinal fluid pressure is described. A method for fabrication of the catheter and shunting the cerebral fluid from the cerebral ventricles to other areas of the body is also considered. Shunt flow failure occurs if the ventricle collapse due to improper valve function causing overdrainage. The ventricular catheter comprises a multiplicity of inlet microtubules. Each microtubule has both a large openings at its inlet end and a multiplicity of microscopic openings along its lateral surfaces.

  3. [Sodium hydrosulfide improves cardiac functions and structures in rats with chronic heart failure].

    PubMed

    Li, Xiao-hui; Zhang, Chao-ying; Zhang, Ting

    2011-11-22

    To explore the effects of sodium hydrosulfide (NaHS), a hydrogen sulphide (H(2)S) donor, on cardiac functions and structures in rats with chronic heart failure induced by volume overload and examine its influence on cardiac remodelling. A total of 47 SD rats (120 - 140 g) were randomly divided into 5 groups:shunt group (n = 11), sham group (n = 8), shunt + NaHS group (n = 10), sham + NaHS group (n = 8) and shunt + phentolamine group (n = 10). The rat model of chronic heart failure was induced by abdominal aorta-inferior vena cava puncture. At Week 8 post-operation, hemodynamic parameters, microstructures and ultrastructures of myocardial tissues were analyzed. Extracellular collagen content in myocardial tissues was analyzed after Sirius red staining. Right ventricular hydroxyproline concentration was determined and compared. At Week 8 post-operation, compared with the sham operation and shunt + NaHS groups, the shunt group showed significantly increased right ventricular systolic pressure (RVSP) and right ventricular end diastolic pressure (RVEDP) (mm Hg: 35.2 ± 3.9 vs 21.4 ± 3.7 and 28.1 ± 2.7, 32 ± 5 vs 21 ± 4 and 26 ± 4, all P < 0.05, 1 mm Hg = 0.133 kPa). The RV peak rate of contraction and relaxation markedly decreased (RV ± dp/dt max) (mm Hg/s: 1528 ± 113 vs 2336 ± 185 and 1835 ± 132, 1331 ± 107 vs 2213 ± 212 and 1768 ± 116, all P < 0.05). It was found microscopically that myocardial fibers in the shunt group were irregularly arranged, partially cytolysis and infiltrated by inflammatory cells. Electron microscopy revealed that myocardial fibers thickened non-uniformly in the shunt group, some fiber mitochondria were highly swollen and contained vacuoles. And sarcoplasmic reticulum appeared slightly dilated. Polarized microscopy indicated that, collagen content (particularly type-I collagen) increased in the shunt group compared with the sham operation group. Additionally, compared with the shunt group, the shunt and NaHS treatment groups showed an amelioration of myocardial damage, an alleviation of myocardial fiber changes and a decrease in myocardial collagen content (particularly type-I collagen). Compared with the sham operation and shunt + NaHS groups, the shunt group displayed increased right ventricular hydroxyproline (mg×g(-1)·pro: 1.32 ± 0.25 vs 0.89 ± 0.18 and 0.83 ± 0.19, all P < 0.05). H(2)S may improve cardiac functions and ameliorate cardiac structures in rats with chronic heart failure probably through dilating the blood vessels and affecting the extracellular collagen metabolism.

  4. Oral glutamine challenge and magnetic resonance spectroscopy in three patients with congenital portosystemic shunts.

    PubMed

    Ortiz, María; Córdoba, Juan; Alonso, Juli; Rovira, Alex; Quiroga, Sergi; Jacas, Carlos; Esteban, Rafael; Guardia, Jaume

    2004-03-01

    Congenital portosystemic shunts are rare abnormalities of liver vasculature that can cause neurological symptoms, probably secondarily to the effects of the metabolism of ammonia in the brain. Our aim was to investigate the relationship between capillary blood ammonia after oral glutamine challenge and magnetic resonance spectroscopy in three patients with congenital portosystemic shunts. Neuropsychological tests, oral glutamine challenge and magnetic resonance spectroscopy were performed at baseline and after 6 months of follow-up in three patients with congenital portosystemic shunts. The results were compared to those obtained in a group of six cirrhotic patients with prior episodes of hepatic encephalopathy and healthy controls. Patients with congenital portosystemic shunts exhibited abnormalities of neuropsychological tests, magnetic resonance spectroscopy and a response to the oral glutamine challenge similar to those observed in patients with cirrhosis. The intensity of the rise of brain glutamine was correlated to the area under the curve of ammonia after the oral glutamine challenge (R=0.72). Neurological manifestations of patients with congenital portosystemic shunts are mediated through similar mechanisms that are involved in the pathogenesis of hepatic encephalopathy. The area under the curve appears to be the better parameter that defines the response to the oral glutamine challenge.

  5. Fuzzy Inference System Approach for Locating Series, Shunt, and Simultaneous Series-Shunt Faults in Double Circuit Transmission Lines

    PubMed Central

    Swetapadma, Aleena; Yadav, Anamika

    2015-01-01

    Many schemes are reported for shunt fault location estimation, but fault location estimation of series or open conductor faults has not been dealt with so far. The existing numerical relays only detect the open conductor (series) fault and give the indication of the faulty phase(s), but they are unable to locate the series fault. The repair crew needs to patrol the complete line to find the location of series fault. In this paper fuzzy based fault detection/classification and location schemes in time domain are proposed for both series faults, shunt faults, and simultaneous series and shunt faults. The fault simulation studies and fault location algorithm have been developed using Matlab/Simulink. Synchronized phasors of voltage and current signals of both the ends of the line have been used as input to the proposed fuzzy based fault location scheme. Percentage of error in location of series fault is within 1% and shunt fault is 5% for all the tested fault cases. Validation of percentage of error in location estimation is done using Chi square test with both 1% and 5% level of significance. PMID:26413088

  6. Noninvasive Thermal Evaluation of Ventriculoperitoneal Shunt Patency and Cerebrospinal Fluid Flow Using a Flow Enhancing Device.

    PubMed

    Hameed, Mustafa Q; Zurakowski, David; Proctor, Mark R; Stone, Scellig S D; Warf, Benjamin C; Smith, Edward R; Goumnerova, Liliana C; Swoboda, Marek; Anor, Tomer; Madsen, Joseph R

    2018-06-16

    While a noninvasive flow determination would be desirable in the diagnosis of cerebrospinal fluid shunt malfunction, existing studies have not yet defined a role for thermal flow detection. To evaluate a revised test protocol using a micropumper designed to transiently enhance flow during thermal testing to determine whether thermal detection of flow is associated with progression to shunt revision surgery. Eighty-two unique tests were performed in 71 shunts. The primary outcome, need for revision within 7 d of testing, was compared with results of micropumper-augmented thermal flow detection. Statistical analysis was based on blind interpretation of test results and raw temperature data recorded during testing. The test was sensitive (73%) and specific (68%) in predicting need for revision, with 5.6-fold higher probability of revision when flow was not detected. Negative predictive value in our sample was 94.2%. The probability of not requiring revision increased with increasing total temperature drop. Analysis of various possible thresholds showed that the optimal temperature cutoff may be lower than suggested by the manufacturer (0.125°C vs 0.2°C). This is the first study to report a strong association between thermal flow evaluation and a clinical impression that a shunt is not malfunctioning. The current recommended threshold may increase the false positive rate unnecessarily, and as clinicians gain experience with the method, they may find value in examining the temperature curves themselves. Multicenter studies are suggested to further define a role for this diagnostic test.

  7. Multi-resonant piezoelectric shunting induced by digital controllers for subwavelength elastic wave attenuation in smart metamaterial

    NASA Astrophysics Data System (ADS)

    Wang, Gang; Cheng, Jianqing; Chen, Jingwei; He, Yunze

    2017-02-01

    Instead of analog electronic circuits and components, digital controllers that are capable of active multi-resonant piezoelectric shunting are applied to elastic metamaterials integrated with piezoelectric patches. Thanks to recently introduced digital control techniques, shunting strategies are possible now with transfer functions that can hardly be realized with analog circuits. As an example, the ‘pole-zero’ method is developed to design single- or multi-resonant bandgaps by adjusting poles and zeros in the transfer function of piezoelectric shunting directly. Large simultaneous attenuations in up to three frequency bands at deep subwavelength scale (with normalized frequency as low as 0.077) are achieved. The underlying physical mechanism is attributable to the negative group velocity of the flexural wave within bandgaps. As digital controllers can be readily adapted via wireless broadcasting, the bandgaps can be tuned easily unlike the electric components in analog shunting circuits, which must be tuned one by one manually. The theoretical results are verified experimentally with the measured vibration transmission properties, where large insulations of up to 20 dB in low-frequency ranges are observed.

  8. Risk factors for shunt malfunction in pediatric hydrocephalus: a multicenter prospective cohort study.

    PubMed

    Riva-Cambrin, Jay; Kestle, John R W; Holubkov, Richard; Butler, Jerry; Kulkarni, Abhaya V; Drake, James; Whitehead, William E; Wellons, John C; Shannon, Chevis N; Tamber, Mandeep S; Limbrick, David D; Rozzelle, Curtis; Browd, Samuel R; Simon, Tamara D

    2016-04-01

    OBJECT The rate of CSF shunt failure remains unacceptably high. The Hydrocephalus Clinical Research Network (HCRN) conducted a comprehensive prospective observational study of hydrocephalus management, the aim of which was to isolate specific risk factors for shunt failure. METHODS The study followed all first-time shunt insertions in children younger than 19 years at 6 HCRN centers. The HCRN Investigator Committee selected, a priori, 21 variables to be examined, including clinical, radiographic, and shunt design variables. Shunt failure was defined as shunt revision, subsequent endoscopic third ventriculostomy, or shunt infection. Important a priori-defined risk factors as well as those significant in univariate analyses were then tested for independence using multivariate Cox proportional hazard modeling. RESULTS A total of 1036 children underwent initial CSF shunt placement between April 2008 and December 2011. Of these, 344 patients experienced shunt failure, including 265 malfunctions and 79 infections. The mean and median length of follow-up for the entire cohort was 400 days and 264 days, respectively. The Cox model found that age younger than 6 months at first shunt placement (HR 1.6 [95% CI 1.1-2.1]), a cardiac comorbidity (HR 1.4 [95% CI 1.0-2.1]), and endoscopic placement (HR 1.9 [95% CI 1.2-2.9]) were independently associated with reduced shunt survival. The following had no independent associations with shunt survival: etiology, payer, center, valve design, valve programmability, the use of ultrasound or stereotactic guidance, and surgeon experience and volume. CONCLUSIONS This is the largest prospective study reported on children with CSF shunts for hydrocephalus. It confirms that a young age and the use of the endoscope are risk factors for first shunt failure and that valve type has no impact. A new risk factor-an existing cardiac comorbidity-was also associated with shunt failure.

  9. Embolization of congenital intrahepatic porto-systemic shunt by n-butyl cyanoacrylate.

    PubMed

    Gupta, Vivek; Kalra, Naveen; Vyas, Sameer; Sodhi, K S; Thapa, B R; Khandelwal, N

    2009-10-01

    Congenital intrahepatic portosystemic venous shunt (IHPSVS) is rare vascular anomaly. We present one case of a 14-month male child who presented with global developmental delay. Child had high ammonia levels with low glutamine and high bile salts on the previous investigations and had history of neonatal seizures since day 13 of life. On admission, serum ammonia levels were elevated to 112micromol/L. Other laboratory investigations including liver and renal function test, and electrolytes were normal. He was, diagnosed to have IHPSVS on the basis of Doppler and CT, and treated by embolization with n-butyl cyanoacrylate (glue). A brief review of diagnostic modalities and endovascular management for the IHPSVS is presented including the present case.

  10. Design, Fabrication, and In Vitro Testing of an Anti-biofouling Glaucoma Micro-shunt.

    PubMed

    Harake, Ryan S; Ding, Yuzhe; Brown, J David; Pan, Tingrui

    2015-10-01

    Glaucoma, one of the leading causes of irreversible blindness, is a progressive neurodegenerative disease. Chronic elevated intraocular pressure (IOP), a prime risk factor for glaucoma, can be treated by aqueous shunts, implantable devices, which reduce IOP in glaucoma patients by providing alternative aqueous outflow pathways. Although initially effective at delaying glaucoma progression, contemporary aqueous shunts often lead to numerous complications and only 50% of implanted devices remain functional after 5 years. In this work, we introduce a novel micro-device which provides an innovative platform for IOP reduction in glaucoma patients. The device design features an array of parallel micro-channels to provide precision aqueous outflow resistance control. Additionally, the device's microfluidic channels are composed of a unique combination of polyethylene glycol materials in order to provide enhanced biocompatibility and resistance to problematic channel clogging from biofouling of aqueous proteins. The microfabrication process employed to produce the devices results in additional advantages such as enhanced device uniformity and increased manufacturing throughput. Surface characterization experimental results show the device's surfaces exhibit significantly less non-specific protein adsorption compared to traditional implant materials. Results of in vitro flow experiments verify the device's ability to provide aqueous resistance control, continuous long-term stability through 10-day protein flow testing, and safety from risk of infection due to bacterial ingression.

  11. The predictive value of external continuous lumbar drainage, with cerebrospinal fluid outflow controlled by medium pressure valve, in normal pressure hydrocephalus.

    PubMed

    Panagiotopoulos, V; Konstantinou, D; Kalogeropoulos, A; Maraziotis, T

    2005-09-01

    Although sporadic studies have described temporary external cerebrospinal fluid (CSF) lumbar drainage as a highly accurate test for predicting the outcome after ventricular shunting in normal pressure hydrocephalus (NPH) patients, a more recent study reports that the positive predictive value of external lumbar drainage (ELD) is high but the negative predictive value is deceptively low. Therefore, we conducted a prospective study in order to evaluate the predictive value of a continuous ELD, with CSF outflow controlled by medium pressure valve, in NPH patients. Twenty-seven patients with presumed NPH were admitted to our department and CSF drainage was carried out by a temporary (ELD) with CSF outflow controlled by a medium pressure valve for five days. All patients received a ventriculoperitoneal shunt using a medium pressure valve based upon preoperative clinical and radiographic criteria of NPH, regardless of ELD outcome. Clinical evaluation of gait disturbances, urinary incontinence and mental status, and radiological evaluation with brain CT was performed prior to and after ELD test, as well as three months after shunting. Twenty-two patients were finally shunted and included in this study. In a three-month follow-up, using a previously validated score system, overall improvement after permanent shunting correlated well to improvement after ELD test (Spearman's rho = 0.462, p = 0.03). When considering any degree of improvement as a positive response, ELD test yielded high positive predictive values for all individual parameters (gait disturbances 94%, 95% CI 71%-100%, urinary incontinence 100%, 95% CI 66%-100%, and mental status 100%, 95% CI 66%-100%) but negative predictive values were low (< 50%) except for cognitive impairment (85%, 95% CI 55%-98%). This study suggests that a positive ELD-valve system test should be considered a reliable criterion for preoperative selection of shunt-responsive NPH patients. In case of a negative ELD-valve system test, further investigation of the presumed NPH patients with additional tests should be performed.

  12. Shunt occlusion for portosystemic shunt syndrome related refractory hepatic encephalopathy-A single-center experience in 21 patients from Kerala.

    PubMed

    Philips, Cyriac Abby; Kumar, Lijesh; Augustine, Philip

    2017-09-01

    Large spontaneous portosystemic shunts (SPSS) are seen in a subset of patients with liver disease and medically refractory recurrent/persistent hepatic encephalopathy (MRHE). Shunt occlusion has been shown to improve clinical outcomes. We retrospectively analyzed patient characteristics, SPSS attributes, procedural features, baseline clinical and investigational parameters, neurological outcomes, adverse effects (procedure and portal hypertension related), and risk factors predicting outcomes in liver disease patients undergoing shunt occlusion procedure for MRHE. Between October 2016 and July 2017, 21 patients (Child-Pugh score, CTP 6 to 13) with mean model of end-stage liver disease (MELD) and MELD-sodium scores 15.7 and 19.3 respectively with MRHE [3-cirrhotic Parkinsonism (CP)] were diagnosed to have single or multiple large SPSSs. A total of 29 shunts were occluded (1 surgical, 20 non-surgical). Recurrent and persistent HE and CP markedly improved in the short (n=20, 1 to 3 months), intermediate (n=12, 3 to 6 months), and long (n=7, 6 to 9 months) follow up. None had spontaneous or persistent HE at a median follow up 105 (30 to 329) days (p<0.05). Motor, speech, sleep abnormalities, daily activities of living, and liver disease severity scores improved significantly on follow up. Baseline arterial ammonia showed a statistically significant reduction in all time periods of follow up after shunt occlusion (p<0.05). CTP >11 predicted mortality post shunt occlusion (p=0.04). Embolization of large SPSS in liver disease patients with MRHE and modestly preserved liver function is safe and efficacious and associated with improved quality of life and can function as a bridge to liver transplantation in accurately selected patients.

  13. Endoscopic Third Ventriculostomy Instead of Shunt Revision in Children Younger Than 3 Years of Age.

    PubMed

    Zhao, Rui; Shi, Wei; Yang, Haowei; Li, Hao

    2016-04-01

    Endoscopic third ventriculostomy (ETV) is a valuable option in the treatment of shunt failure, but no clinical data exist for young children. The aim of this study was to elucidate the role of ETV in patients younger than 3 years of age with shunt malfunction. A cohort of 37 patients younger than 3 years of age with shunt malfunction underwent ETV instead of shunt revision. Patients' preoperative condition and medical history were studied to determine the impact of a number of variables on outcome. The Fisher exact test was used to assess differences among groups. Median age at ETV was 21.6 months (8-36 months). Diagnosis was obstructive hydrocephalus in 24 patients and communicating hydrocephalus in 13. Median age at initial shunt placement was 3.2 months (10 days to 30 months). The etiology of shunt malfunction was obstruction (n = 27) or infection (n = 10). Overall ETV failure rate was 40.5% (15/37). Patients whose age at initial shunt placement was <6 months and/or who had a preterm birth history had higher relative rates of ETV failure. Other variables, including type of hydrocephalus, interval between initial shunt placement and ETV, history of intraventricular bleeding and/or infection, and etiology of shunt malfunction, did not significantly affect the final outcome. Patients younger than 3 years with obstructive or communicating hydrocephalus may benefit from ETV in the event of shunt malfunction and have about a 60% probability of becoming shunt free. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Complications of congenital portosystemic shunts in children: therapeutic options and outcomes.

    PubMed

    Franchi-Abella, Stéphanie; Branchereau, Sophie; Lambert, Virginie; Fabre, Monique; Steimberg, Clarisa; Losay, Jean; Riou, Jean-Yves; Pariente, Danièle; Gauthier, Frédéric; Jacquemin, Emmanuel; Bernard, Olivier

    2010-09-01

    Congenital portosystemic shunts are rare vascular malformations that lead to severe complications. Their management is controversial. The aim of this study was to propose a clear definition of the risks and management of congenital portosystemic shunts in children according to our experience and a review of the literature. Twenty-two children with a complicated congenital portosystemic shunt were studied in our institution. When necessary, management included portal pressure measurement and portal vein angiography during an occlusion test and closure of the shunt by surgical and/or endovascular methods. Five neonates with intrahepatic shunts presented with cholestasis that resolved spontaneously, and 17 older children presented with liver tumors (13) and/or hepatopulmonary syndrome (2), pulmonary artery hypertension (3), portosystemic encephalopathy (3), heart failure (1), and glomerulonephritis (1). The portosystemic shunt was extrahepatic (11) or intrahepatic (6). Portosystemic shunts were closed by endovascular methods in 5 children and surgically in 10, 4 of whom had portal pressure during occlusion above 35 mmHg and extremely hypoplastic or undetectable portal veins requiring banding of the fistula before closure. Shunt closure resulted in restoration of intrahepatic portal flow in all, with complete or partial regression of benign liver masses, and regression or stabilization of pulmonary, cardiac, neurological, and renal complications. Congenital portosystemic shunt carries risks of severe complications in children. Closure of a shunt persisting after age 2 years should be considered preventively. Intrahepatic portal flux restoration can be expected, even when intrahepatic portal veins are extremely hypoplastic or undetectable.

  15. The results of systems tests of the 500 kV busbar controllable shunting reactor in the Tavricheskaya substation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gusev, S. I.; Karpov, V. N.; Kiselev, A. N.

    2009-09-15

    The results of systems tests of the 500 kV busbar magnetization-controllable shunting reactor (CSR), set up in the Tavricheskaya substation, including measurements of the quality of the electric power, the harmonic composition of the network currents of the reactor for different values of the reactive power consumed, the determination of the regulating characteristics of the reactor, the speed of response of the shunting reactor in the current and voltage stabilization modes, and also the operation of the reactor under dynamic conditions for different perturbations, are presented. The results obtained are analyzed.

  16. Congenital portosystemic shunts in children: recognition, evaluation, and management.

    PubMed

    Bernard, O; Franchi-Abella, S; Branchereau, S; Pariente, D; Gauthier, F; Jacquemin, E

    2012-11-01

    Congenital portosystemic shunts are present in one in 30,000 children. Among the associated risks of severe complications are neonatal cholestasis, benign and malignant liver tumors, hepatopulmonary syndrome, portopulmonary hypertension, and encephalopathy. They can be detected on prenatal ultrasonograms, during the investigation of a positive galactosemia screening test in neonates or of a complication, or be found fortuitously on an abdominal ultrasound. Small intrahepatic shunts may resolve spontaneously within one year of age, but other shunts such as extrahepatic, persistent ductus venosus or persisting intrahepatic shunts, must be closed in one or two steps, by interventional radiology techniques or surgically. The plasticity of the intrahepatic portal system allows revascularization of the liver after shunt closure, even when no intrahepatic portal structures can be detected on imaging studies. This leaves little or no place for liver transplantation in the management of these children. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. Congenital intrahepatic portosystemic shunt diagnosed during intrauterine life

    PubMed Central

    Bellettini, Camila Vieira; Wagner, Rafaela; Balzanelo, Aleocídio Sette; Andretta, André Luis de Souza; de Moura, Arthur Nascimento; Fabris, Catia Carolina; Gubert, Eduardo Maranhão

    2016-01-01

    Abstract Objective: To report a patient with prenatal diagnosis of portosystemic shunt; a rare condition in humans. Case description: 17-Day-old female infant admitted for investigation of suspected diagnosis of portosystemic shunt, presumed in obstetric ultrasound. The hypothesis was confirmed after abdominal angiography and liver Doppler. Other tests such as echocardiography and electroencephalogram were performed to investigate possible co-morbidities or associated complications, and were normal. We chose conservative shunt treatment, as there were no disease-related complications and this was intrahepatic shunt, which could close spontaneously by the age of 2 years. Comments: Portosystemic shunt can lead to various complications such as hepatic encephalopathy, hypergalactosemia, liver tumors, and hepatopulmonary syndrome. Most diagnoses are done after one month of age, after such complications occur. The prenatal diagnosis of this patient provided greater security for the clinical picture management, as well as regular monitoring, which allows the anticipation of possible complications and perform interventional procedures when needed. PMID:27133713

  18. Reduction of shunt obstructions by using a peel-away sheath technique? A multicenter prospective randomized trial.

    PubMed

    Kehler, Uwe; Langer, Niels; Gliemroth, Jan; Meier, Ullrich; Lemcke, Johannes; Sprung, Christian; Schlosser, Hans-Georg; Kiefer, Michael; Eymann, Regina; Heese, Oliver

    2012-05-01

    Shunt obstructions may partly be caused by brain debris, which intrude into the ventricular catheter during ventricle puncture. Avoiding contact between the catheter and brain tissue, by using a peel-away sheath, should reduce the number of shunt failures caused by obstruction. To test this hypothesis, we conducted a randomized, prospective multicenter study. 201 patients from 6 different neurosurgical centers in Germany receiving a ventriculo-peritoneal shunt were included in this study. Of these, 177 patients completed a 1-year follow-up period. Surgery was randomized in a 1 to 1 fashion, such that out of 177 procedures, 91 were performed using a peel-away sheath and 86 were performed without. The rate of surgical re-interventions and shunt obstructions within a 12-month period was recorded. Within 1 year post-surgery, 17 shunt obstructions (9.6%) leading to shunt revisions were recorded. However, no difference was found between surgeries performed using a peel-away sheath (9.9%) or not (9.3%). The overall shunt infection rate was 2.8% and the shunt revision rate for overdrainage was 3.9%. The theoretical advantages attributed to the use of a peel-away sheath to introduce a ventricular catheter could not be confirmed in this randomized study, suggesting that the proposed role of brain debris in shunt obstructions may be overestimated. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Photovoltaic power system tests on an 8-kilowatt single-phase line-commutated inverter

    NASA Technical Reports Server (NTRS)

    Stover, J. B.

    1978-01-01

    Efficiency and power factor were measured as functions of solar array voltage and current. The effects of input shunt capacitance and series inductance were determined. Tests were conducted from 15 to 75 percent of the 8 kW rated inverter input power. Measured efficiencies ranged from 76 percent to 88 percent at about 50 percent of rated inverter input power. Power factor ranged from 36 percent to 72 percent.

  20. Twenty-year outcome in young adults with childhood hydrocephalus: assessment of surgical outcome, work participation, and health-related quality of life.

    PubMed

    Paulsen, A Henriette; Lundar, Tryggve; Lindegaard, Karl-Fredrik

    2010-12-01

    Shunting of CSF is one of the most commonly performed operations in the pediatric neurosurgeon's repertoire. The 1st decade after initial shunt insertion has been addressed in several previous reports. The goals of the authors' study, therefore, were to determine 20-year outcomes in young adults with childhood hydrocephalus and to assess their health-related quality of life (HRQOL). Patients younger than 15 years of age, in whom a first-time shunt insertion was performed for hydrocephalus in the calendar years 1985-1988, were included in a retrospective study on surgical morbidity, mortality rates, academic achievement, and/or work participation. Information concerning perceived health and functional status was assessed using the 36-Item Short Form Health Survey (SF-36) and Barthel Index, which were completed by patients still alive by September 1, 2009. Overall, 138 patients participated, no patient being lost to follow-up. For the 20-year period, the overall mortality rate was 21.7%. The mortality rate was not significantly higher in the 1st decade after initial shunt insertion than in the 2nd decade (p = 0.10). Ten percent of the patients surviving still live with their primary shunt in place, whereas 81% required at least one revision, and among these individual the mean number of revisions was 4.2 (median 3, range 0-26). There was a significantly higher revision rate during the 1st decade after initial shunt insertion compared with the 2nd decade (p = 0.027). The majority of patients live lives comparable with those of their peers. At follow-up, 56% were employed in open-market jobs or were still students, 23% had sheltered employment, and 21% were unemployed. The HRQOL was slightly lower in the hydrocephalic cohort than in the normative population. A significant difference was found in 2 of 8 SF-36 domains-Physical Functioning and General Health. During the 20-year follow-up period, 81% of the patients required at least one revision of the CSF shunt. The mortality rate was high: 24 patients died in the 1st decade and 6 died in the 2nd decade after implantation of the initial shunt. In total, 4 deaths (2.9%) were due to shunt failure. Shunt placement to treat childhood hydrocephalus has a substantial effect on social functioning in later life, although perceived health was positively found to be better than expected in young adults with hydrocephalus.

  1. Successful living donor liver transplant in a child with Abernethy malformation with biliary atresia, ventricular septal defect and intrapulmonary shunting.

    PubMed

    Singhal, Ashish; Srivastava, Ajitabh; Goyal, Neerav; Vij, Vivek; Wadhawan, Manav; Bera, Motilal; Gupta, Subash

    2009-12-01

    Congenital portosystemic shunts are the anomalies in which the mesenteric venous drainage bypasses the liver and drains directly into the systemic circulation. This is a report of a rare case of LDLT in a four-yr old male child suffering with biliary atresia (post-failed Kasai procedure) associated with (i) a large congenital CEPSh from the spleno-mesentric confluence to the LHV, (ii) intrapulmonary shunts, (iii) perimembranous VSD. The left lobe graft was procured from the mother of the child. Recipient IVC and the shunt vessel were preserved during the hepatectomy, and the caval and shunt clamping were remarkably short while performing the HV and portal anastomosis. Post-operative course was uneventful; intrapulmonary shunts regressed within three months after transplantation and currently after 18 months following transplant child is doing well with normal liver functions. CEPSh has been extensively discussed and all the published cases of liver transplantation for CEPSh were reviewed.

  2. [Cognitive event-related brain potentials (P300) in patients with normal pressure hydrocephalus. Results of a prospective study].

    PubMed

    de la Calzada, M D; Poca, M A; Sahuquillo, J; Matarín, M; Mataró, M; Solana, E

    2010-01-01

    To determine the response to cognitive event-related potentials (P300) in patients with normal-pressure hydrocephalus (NPH) and their relationship with clinical and cognitive status before and after shunt surgery. We performed a prospective study in a series of 26 patients with NPH who underwent clinical and cognitive assessment before surgery and 6 months afterwards. Visual P300 potentials obtained before and after treatment were also compared with those obtained in 18 healthy volunteers. Before shunting, the P300 wave was detected in 11 (42.3%) NPH patients, compared with the 18 (100%) volunteers. Six months after shunting, the P300 wave was found in 20 (76.9%) NPH patients. P300 latency was significantly longer in NPH patients than in the control group before surgery, but not at 6 months after surgery. No significant differences in neuropsychological studies or in the level of dependence for daily life activities were found between the subgroups of NPH patients with and without pre-surgical P300 waves, or between changes in P300 parameters and clinical and cognitive changes. The P300 wave was delayed or undetectable in a substantial percentage of patients with NPH before surgery. These alterations can be reversed by shunting. P300 analysis and neuropsychological tests could be complementary measures to evaluate functional status in patients with NPH.

  3. The predictive value of ventricular CSF removal in normal pressure hydrocephalus.

    PubMed

    Krauss, J K; Regel, J P

    1997-08-01

    We report the impact of diagnostic ventricular CSF removal (VCR) on the gait disturbance in 24 patients with suspected normal pressure hydrocephalus (NPH) who had an intraventricular catheter for studies of CSF dynamics in order to select patients for shunt surgery. There were no complications related to removal of 24 ml CSF over a period of 6 hours in four instances or to the removal of 15-18 ml at one time in twenty instances. Seventeen out of 24 patients were diagnosed as having NPH. Two of those patients who had relatively mild symptoms had a prolonged amelioration of their gait disturbance after diagnostic VCR. Thirteen patients underwent subsequent shunt operations. Eleven of them had good functional and symptomatic improvement on follow-up. In those six patients who had a marked amelioration of their gait disturbance after diagnostic VCR, not only improvement of the gait disturbance was observed after shunting, but a consistent overall improvement as well. The predictive value of VCR was more variable in those six patients who had only a moderate response to VCR. No change of the gait disturbance after VCR was noted in seven patients in whom the diagnosis of NPH was not confirmed. Diagnostic VCR might be a valuable ancillary test in specialized centers which routinely use intraventricular CSF monitoring in the selection of patients for shunt surgery.

  4. Neuroimaging in normal pressure hydrocephalus

    PubMed Central

    Damasceno, Benito Pereira

    2015-01-01

    Normal pressure hydrocephalus (NPH) is a syndrome characterized by the triad of gait disturbance, mental deterioration and urinary incontinence, associated with ventriculomegaly and normal cerebrospinal fluid (CSF) pressure. The clinical presentation (triad) may be atypical or incomplete, or mimicked by other diseases, hence the need for supplementary tests, particularly to predict postsurgical outcome, such as CSF tap-tests and computed tomography (CT) or magnetic resonance imaging (MRI). The CSF tap-test, especially the 3 to 5 days continuous external lumbar drainage of at least 150 ml/day, is the only procedure that simulates the effect of definitive shunt surgery, with high sensitivity (50-100%) and high positive predictive value (80-100%). According to international guidelines, the following are CT or MRI signs decisive for NPH diagnosis and selection of shunt-responsive patients: ventricular enlargement disproportionate to cerebral atrophy (Evans index >0.3), and associated ballooning of frontal horns; periventricular hyperintensities; corpus callosum thinning and elevation, with callosal angle between 40º and 90º; widening of temporal horns not fully explained by hippocampal atrophy; and aqueductal or fourth ventricular flow void; enlarged Sylvian fissures and basal cistern, and narrowing of sulci and subarachnoid spaces over the high convexity and midline surface of the brain. On the other hand, other imaging methods such as radionuclide cisternography, SPECT, PET, and also DTI or resting-state functional MRI, although suitable for NPH diagnosis, do not yet provide improved accuracy for identifying shunt-responsive cases. PMID:29213984

  5. Shunt Intervention for Possible Idiopathic Normal Pressure Hydrocephalus Improves Patient Outcomes: A Nationwide Hospital-Based Survey in Japan.

    PubMed

    Nakajima, Madoka; Miyajima, Masakazu; Ogino, Ikuko; Akiba, Chihiro; Kawamura, Kaito; Kurosawa, Michiko; Kuriyama, Nagato; Watanabe, Yoshiyuki; Fukushima, Wakaba; Mori, Etsuro; Kato, Takeo; Sugano, Hidenori; Karagiozov, Kostadin; Arai, Hajime

    2018-01-01

    Background and Purpose: This study aimed to investigate the efficacy of cerebrospinal fluid shunt intervention for idiopathic normal pressure hydrocephalus (iNPH) using data from a nationwide epidemiological survey in Japan. Methods: We conducted a cross-sectional study using data from a nationwide epidemiological survey performed in Japan. Propensity score matching was used to select 874 patients from 1,423 patients aged ≥60 years, who were diagnosed with iNPH based on clinical guidelines following a hospital visit in 2012. Patients who experienced an improvement of at least 1 modified Rankin Scale (mRS) grade after the intervention were classified as "improved," while the remaining patients were classified as "non-improved." In the shunt intervention ( n = 437) and non-shunt intervention ( n = 437) groups, the differences in mRS grade improvement were analyzed using the Mann-Whitney U -test. Finally, we examined subjects in the shunt intervention group ( n = 974) to compare the outcomes and complications of ventriculoperitoneal (VP) shunt (n = 417) with lumboperitoneal (LP) shunt ( n = 540). Results: We examined subjects with iNPH to compare the non-shunt intervention group to the shunt intervention group following adjustment for age and mRS grade at baseline by propensity score matching (0.31-0.901). The mRS grade (mean [SD]) was found to improve with non-shunt intervention (2.46 [0.88]) and shunt intervention (1.93 [0.93]) ( p < 0.001) in iNPH patients. The mRS outcome score and complications comparison between the VP and LP shunt groups did not show significant difference. Conclusions: In this study, analysis of the efficacy of shunts for possible iNPH conducted in Japan indicated a significant improvement in the mRS grade between baseline and outcome within 1 year, regardless of the surgical technique, and shunt intervention was found to be effective.

  6. Parylene MEMS patency sensor for assessment of hydrocephalus shunt obstruction.

    PubMed

    Kim, Brian J; Jin, Willa; Baldwin, Alexander; Yu, Lawrence; Christian, Eisha; Krieger, Mark D; McComb, J Gordon; Meng, Ellis

    2016-10-01

    Neurosurgical ventricular shunts inserted to treat hydrocephalus experience a cumulative failure rate of 80 % over 12 years; obstruction is responsible for most failures with a majority occurring at the proximal catheter. Current diagnosis of shunt malfunction is imprecise and involves neuroimaging studies and shunt tapping, an invasive measurement of intracranial pressure and shunt patency. These patients often present emergently and a delay in care has dire consequences. A microelectromechanical systems (MEMS) patency sensor was developed to enable direct and quantitative tracking of shunt patency in order to detect proximal shunt occlusion prior to the development of clinical symptoms thereby avoiding delays in treatment. The sensor was fabricated on a flexible polymer substrate to eventually allow integration into a shunt. In this study, the sensor was packaged for use with external ventricular drainage systems for clinical validation. Insights into the transduction mechanism of the sensor were obtained. The impact of electrode size, clinically relevant temperatures and flows, and hydrogen peroxide (H2O2) plasma sterilization on sensor function were evaluated. Sensor performance in the presence of static and dynamic obstruction was demonstrated using 3 different models of obstruction. Electrode size was found to have a minimal effect on sensor performance and increased temperature and flow resulted in a slight decrease in the baseline impedance due to an increase in ionic mobility. However, sensor response did not vary within clinically relevant temperature and flow ranges. H2O2 plasma sterilization also had no effect on sensor performance. This low power and simple format sensor was developed with the intention of future integration into shunts for wireless monitoring of shunt state and more importantly, a more accurate and timely diagnosis of shunt failure.

  7. Experimental Comparison of Piezoelectric and Magnetostrictive Shunt Dampers

    NASA Technical Reports Server (NTRS)

    Asnani, Vivake M.; Deng, Zhangxian; Dapino, Marcelo J.; Scheidler, Justin J.

    2016-01-01

    A novel mechanism called the vibration ring is being developed to enable energy conversion elements to be incorporated into the driveline of a helicopter or other rotating machines. Unwanted vibration is transduced into electrical energy, which provides a damping effect on the driveline. The generated electrical energy may also be used to power other devices (e.g., health monitoring sensors). PZT (piezoceramic) and PMN-30PT (single crystal) stacks, as well as a Tb_0.3 Dy_0.7 Fe_1.92 (Terfenol-D) rod with a bias magnet array and a pickup coil, were tested as alternative energy conversion elements to use within the vibration ring. They were tuned for broadband damping using shunt resistors, and dynamic compression testing was conducted in a high-speed load frame. Energy conversion was experimentally optimized at 750Hz by tuning the applied bias stress and resistance values. Dynamic testing was conducted up to 1000Hz to determine the effective compressive modulus, shunt loss factor, internal loss factor, and total loss factor. Some of the trends of modulus and internal loss factor versus frequency were unexplained. The single crystal device exhibited the greatest shunt loss factor whereas the Terfenol-D device had the highest internal and total loss factors. Simulations revealed that internal losses in the Terfenol-D device were elevated by eddy current effects, and an improved magnetic circuit could enhance its shunt damping capabilities. Alternatively, the Terfenol-D device may be simplified to utilize only the eddy current dissipation mechanism (no pickup coil or shunt) to create broadband damping.

  8. Experimental Comparison of Piezoelectric and Magnetostrictive Shunt Dampers

    NASA Technical Reports Server (NTRS)

    Asnani, Vivake M.; Deng, Zhangxian; Scheidler, Justin J.; Dapino, Marcelo J.

    2016-01-01

    A novel mechanism called the vibration ring is being developed to enable energy conversion elements to be incorporated into the driveline of a helicopter or other rotating machines. Unwanted vibration is transduced into electrical energy, which provides a damping effect on the driveline. The generated electrical energy may also be used to power other devices (e.g., health monitoring sensors). PZT (piezoceramic) and PMN-30%PT (single crystal) stacks, as well as a Tb_0.3 Dy_0.7 Fe_1.92 (Terfenol-D) rod with a bias magnet array and a pickup coil, were tested as alternative energy conversion elements to use within the vibration ring. They were tuned for broadband damping using shunt resistors, and dynamic compression testing was conducted in a high-speed load frame. Energy conversion was experimentally optimized at 750Hz by tuning the applied bias stress and resistance values. Dynamic testing was conducted up to 1000Hz to determine the effective compressive modulus, shunt loss factor, internal loss factor, and total loss factor. Some of the trends of modulus and internal loss factor versus frequency were unexplained. The single crystal device exhibited the greatest shunt loss factor whereas the Terfenol-D device had the highest internal and total loss factors. Simulations revealed that internal losses in the Terfenol-D device were elevated by eddy current effects, and an improved magnetic circuit could enhance its shunt damping capabilities. Alternatively, the Terfenol-D device may be simplified to utilize only the eddy current dissipation mechanism (no pickup coil or shunt) to create broadband damping.

  9. Experimental comparison of piezoelectric and magnetostrictive shunt dampers

    NASA Astrophysics Data System (ADS)

    Asnani, Vivake M.; Deng, Zhangxian; Scheidler, Justin J.; Dapino, Marcelo J.

    2016-04-01

    A novel mechanism called the vibration ring is being developed to enable energy conversion elements to be incorporated into the driveline of a helicopter or other rotating machines. Unwanted vibration is transduced into electrical energy, which provides a damping effect on the driveline. The generated electrical energy may also be used to power other devices (e.g., health monitoring sensors). PZT (`piezoceramic') and PMN-30%PT (`single crystal') stacks, as well as a Tb0.3Dy0.7Fe1.92 (`Terfenol-D') rod with a bias magnet array and a pickup coil, were tested as alternative energy conversion elements to use within the vibration ring. They were tuned for broadband damping using shunt resistors, and dynamic compression testing was conducted in a high-speed load frame. Energy conversion was experimentally optimized at 750Hz by tuning the applied bias stress and resistance values. Dynamic testing was conducted up to 1000Hz to determine the effective compressive modulus, shunt loss factor, internal loss factor, and total loss factor. Some of the trends of modulus and internal loss factor versus frequency were unexplained. The single crystal device exhibited the greatest shunt loss factor whereas the Terfenol-D device had the highest internal and total loss factors. Simulations revealed that internal losses in the Terfenol-D device were elevated by eddy current effects, and an improved magnetic circuit could enhance its shunt damping capabilities. Alternatively, the Terfenol-D device may be simplified to utilize only the eddy current dissipation mechanism (no pickup coil or shunt) to create broadband damping.

  10. Congenital intrahepatic portosystemic shunt diagnosed during intrauterine life.

    PubMed

    Bellettini, Camila Vieira; Wagner, Rafaela; Sette Balzanelo, Aleocídio; de Souza Andretta, André Luis; Nascimento de Moura, Arthur; Fabris, Catia Carolina; Maranhão Gubert, Eduardo

    2016-09-01

    To report a patient with prenatal diagnosis of portosystemic shunt; a rare condition in humans. 17-day-old female infant admitted for investigation of suspected diagnosis of portosystemic shunt, presumed in obstetric ultrasound. The hypothesis was confirmed after abdominal angiography and liver Doppler. Other tests such as echocardiography and electroencephalogram were performed to investigate possible co-morbidities or associated complications, and were normal. We chose conservative shunt treatment, as there were no disease-related complications and this was intrahepatic shunt, which could close spontaneously by the age of 2 years. Portosystemic shunt can lead to various complications such as hepatic encephalopathy, hypergalactosemia, liver tumors, and hepatopulmonary syndrome. Most diagnoses are done after one month of age, after such complications occur. The prenatal diagnosis of this patient provided greater security for the clinical picture management, as well as regular monitoring, which allows the anticipation of possible complications and perform interventional procedures when needed. Copyright © 2016. Publicado por Elsevier Editora Ltda.

  11. Analysis of the microRNA signature driving adaptive right ventricular hypertrophy in an ovine model of congenital heart disease.

    PubMed

    Kameny, Rebecca Johnson; He, Youping; Zhu, Terry; Gong, Wenhui; Raff, Gary W; Chapin, Cheryl J; Datar, Sanjeev A; Boehme, Jason; Hata, Akiko; Fineman, Jeffrey R

    2018-06-15

    The right ventricular (RV) response to pulmonary arterial hypertension (PAH) is heterogeneous. Most patients have maladaptive changes with RV dilation and failure while some-especially patients with PAH secondary to congenital heart disease (CHD)-have an adaptive response with hypertrophy and preserved systolic function. Mechanisms for RV adaptation to PAH are unknown despite RV function being a primary determinant of mortality. In our CHD ovine model with fetally-implanted aortopulmonary shunt (shunt lambs), we previously demonstrated an adaptive physiologic RV response to increased afterload with hypertrophy. In this study, we examined small noncoding microRNA (miRNA) expression in shunt RV and characterized downstream effects of a key miRNA. RV tissue was harvested from 4-week-old shunt and control lambs (n=5) and miRNA, mRNA, and proteins were quantitated. We found differential expression of 40 cardiovascular-specific miRNA in shunt RV. Interestingly, this miRNA signature is distinct from models of RV failure, suggesting that miRNAs might contribute to adaptive RV hypertrophy. Among RV miRNAs, miR-199b is decreased in RV with eventual downregulation of nuclear factor of activated T-cells (NFAT)/calcineurin signaling. Furthermore, anti-fibrotic miR-29a is increased in shunt RV with reduction of miR-29 targets Collagen A1 and 3A1 and decreased fibrosis. Thus, we conclude that the miRNA signature specific to shunt lambs is distinct from RV failure and drives gene expression required for adaptive RV hypertrophy. We propose that the adaptive RV miRNA signature may serve as a prognostic and therapeutic tool in patients with PAH to attenuate or prevent progression of RV failure and premature death.

  12. The Bohr Effect Is Not a Likely Promoter of Renal Preglomerular Oxygen Shunting

    PubMed Central

    Olgac, Ufuk; Kurtcuoglu, Vartan

    2016-01-01

    The aim of this study was to evaluate whether possible preglomerular arterial-to-venous oxygen shunting is affected by the interaction between renal preglomerular carbon dioxide and oxygen transport. We hypothesized that a reverse (venous-to-arterial) shunting of carbon dioxide will increase partial pressure of carbon dioxide and decrease pH in the arteries and thereby lead to increased oxygen offloading and consequent oxygen shunting. To test this hypothesis, we employed a segment-wise three-dimensional computational model of coupled renal oxygen and carbon dioxide transport, wherein coupling is achieved by shifting the oxygen-hemoglobin dissociation curve in dependence of local changes in partial pressure of carbon dioxide and pH. The model suggests that primarily due to the high buffering capacity of blood, there is only marginally increased acidity in the preglomerular vasculature compared to systemic arterial blood caused by carbon dioxide shunting. Furthermore, effects of carbon dioxide transport do not promote but rather impair preglomerular oxygen shunting, as the increase in acidity is higher in the veins compared to that in the arteries. We conclude that while substantial arterial-to-venous oxygen shunting might take place in the postglomerular vasculature, the net amount of oxygen shunted at the preglomerular vasculature appears to be marginal. PMID:27833564

  13. Analysis and experimental evaluation of shunt active power filter for power quality improvement based on predictive direct power control.

    PubMed

    Aissa, Oualid; Moulahoum, Samir; Colak, Ilhami; Babes, Badreddine; Kabache, Nadir

    2017-10-12

    This paper discusses the use of the concept of classical and predictive direct power control for shunt active power filter function. These strategies are used to improve the active power filter performance by compensation of the reactive power and the elimination of the harmonic currents drawn by non-linear loads. A theoretical analysis followed by a simulation using MATLAB/Simulink software for the studied techniques has been established. Moreover, two test benches have been carried out using the dSPACE card 1104 for the classic and predictive DPC control to evaluate the studied methods in real time. Obtained results are presented and compared in this paper to confirm the superiority of the predictive technique. To overcome the pollution problems caused by the consumption of fossil fuels, renewable energies are the alternatives recommended to ensure green energy. In the same context, the tested predictive filter can easily be supplied by a renewable energy source that will give its impact to enhance the power quality.

  14. Time-related patterns of ventricular shunt failure.

    PubMed

    Kast, J; Duong, D; Nowzari, F; Chadduck, W M; Schiff, S J

    1994-11-01

    Proximal obstruction is reported to be the most common cause of ventriculoperitoneal (VP) shunt failure, suggesting that imperfect ventricular catheter placement and inadequate valve mechanisms are major causes. This study retrospectively examined patterns of shunt failure in 128 consecutive patients with symptoms of shunt malfunction over a 2-year period. Factors analyzed included site of failure, time from shunt placement or last revision to failure, age of patient at time of failure, infections, and primary etiology of the hydrocephalus. One hundred of these patients required revisions; 14 revisions were due to infections. In this series there was a higher incidence of distal (43%) than of proximal (35%) failure. The difference was not statistically significant when the overall series was considered; however, when factoring time to failure as a variable, marked differences were noted regardless of the underlying cause of hydrocephalus or the age of the patient. Of the 49 patients needing a shunt revision or replacement within 2 years of the previous operation, 50% had proximal malfunction, 14% distal, and 10% had malfunctions attributable directly to the valve itself. Also, 12 of the 14 infections occurred during this time interval. In sharp contrast, of the 51 patients having shunt failure from 2 to more than 12 years after the previous procedure, 72% had distal malfunction, 21% proximal, and only 6% had a faulty valve or infection. This difference between time to failure for proximal versus distal failures was statistically significant (P < 0.00001 for both Student's t-test and non-parametric Mann-Whitney U-test).(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Percutaneous vesicoamniotic shunting versus conservative management for fetal lower urinary tract obstruction (PLUTO): a randomised trial.

    PubMed

    Morris, Rachel K; Malin, Gemma L; Quinlan-Jones, Elisabeth; Middleton, Lee J; Hemming, Karla; Burke, Danielle; Daniels, Jane P; Khan, Khalid S; Deeks, Jon; Kilby, Mark D

    2013-11-02

    Fetal lower urinary tract obstruction (LUTO) is associated with high perinatal and long-term childhood mortality and morbidity. We aimed to assess the effectiveness of vesicoamniotic shunting for treatment of LUTO. In a randomised trial in the UK, Ireland, and the Netherlands, women whose pregnancies with a male fetus were complicated by isolated LUTO were randomly assigned by a central telephone and web-based randomisation service to receive either the intervention (placement of vesicoamniotic shunt) or conservative management. Allocation could not be masked from clinicians or participants because of the invasive nature of the intervention. Diagnosis was by prenatal ultrasound. The primary outcome was survival of the baby to 28 days postnatally. All primary analyses were done on an intention-to-treat basis, but these results were compared with those of an as-treated analysis to investigate the effect of a fairly large proportion of crossovers. We used Bayesian methods to estimate the posterior probability distribution of the effectiveness of vesicoamniotic shunting at 28 days. The study is registered with the ISRCTN Register, number ISRCTN53328556. 31 women with singleton pregnancies complicated by LUTO were included in the trial and main analysis, with 16 allocated to the vesicoamniotic shunt group and 15 to the conservative management group. The study closed early because of poor recruitment. There were 12 livebirths in each group. In the vesicoamniotic shunt group one intrauterine death occurred and three pregnancies were terminated. In the conservative management group one intrauterine death occurred and two pregnancies were terminated. Of the 16 pregnancies randomly assigned to vesicoamniotic shunting, eight neonates survived to 28 days, compared with four from the 15 pregnancies assigned to conservative management (intention-to-treat relative risk [RR] 1·88, 95% CI 0·71-4·96; p=0·27). Analysis based on treatment received showed a larger effect (3·20, 1·06-9·62; p=0·03). All 12 deaths were caused by pulmonary hypoplasia in the early neonatal period. Sensitivity analysis in which non-treatment-related terminations of pregnancy were excluded made some slight changes to point estimates only. Bayesian analysis in which the trial data were combined with elicited priors from experts suggested an 86% probability that vesicoamniotic shunting increased survival at 28 days and a 25% probability that it had a large, clinically important effect (defined as a relative increase of 55% or more in the proportion of neonates who survived). There was substantial short-term and long-term morbidity in both groups, including poor renal function-only two babies (both in the shunt group) survived to 2 years with normal renal function. Seven complications occurred in six fetuses from the shunt group, including spontaneous ruptured membranes, shunt blockage, and dislodgement. These complications resulted in four pregnancy losses. Survival seemed to be higher in the fetuses receiving vesicoamniotic shunting, but the size and direction of the effect remained uncertain, such that benefit could not be conclusively proven. Our results suggest that the chance of newborn babies surviving with normal renal function is very low irrespective of whether or not vesicoamniotic shunting is done. UK National Institute of Health Research, Wellbeing of Women, Hannah Eliza Guy Charity (Birmingham Children's Hospital Charity). Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. [The current state of the surgery of portal hypertension].

    PubMed

    Mercado, M A; Orozco, H

    1992-01-01

    Surgery for bleeding portal hypertension has evolved widely in the last decades. The surgical procedures that preserve portal blood flow are the first operative choice for well selected patients. Operative procedures that deprive the portal blood flow to the liver, are most likely to promote deterioration of liver function in the late postoperative period. The operation most frequently performed are the selective shunts (Warren) and the thoraco abdominal devascularization (Sugiura). The best results are obtained in patients with a good liver function that are operated in an elective fashion. Non-selective shunts have a restricted indication and low diameter porto systemic shunts are still under evaluation. The combination of drug therapy and/or sclerotherapy with surgery appears to improve survival. Liver transplants are indicated for those patients with associated liver failure. For patients with good liver function, surgery is the therapy of choice.

  17. [Feto-amniotic shunting for lower urinary tract obstruction (LUTO)--a case report].

    PubMed

    Lautmann, K; Staboulidou, I; Schippert, C; Hillemanns, P; Wüstemann, M

    2007-12-01

    Posterior urethral valves are the main cause of fetal lower urinary tract obstruction (LUTO) with typical sonographic signs like urinary tract dilatation and reduction of amniotic fluid. LUTO is associated with a high rate of perinatal mortality and is the main cause of kidney failure in early childhood. In such cases vesico-amniotic shunting is a common but risky procedure of fetal surgery to prevent anhydramnion and lethal lung hypoplasia. This case report demonstrates that lung hypoplasia can be prevented by vesico-amniotic shunting of the fetal megacytis in the 23rd week of gestation in a fetus with lower urinary tract obstruction and anhydramnion. The prenatal measured concentration of cystatin C in the fetal urine correlated with the postnatal impaired kidney function. The indication and therapeutic benefit of vesico-amniotic shunting remain controversially discussed in the literature because until today there is no evidence for a reduction in perinatal or long-term morbidity due to early fetal kidney damage. The earlier ultrasound detection of LUTO during the first trimester of pregnancy proposes the possibility of earlier intervention and protection of nephrogenesis. First case studies about first trimester vesico-amniotic shunting have been published; the influence on the postnatal kidney function merits further well-structured investigation.

  18. Hepatic encephalopathy secondary to a splenorenal shunt that manifested a long time after a liver transplantation.

    PubMed

    Tomás Pujante, Paula; Jiménez Sánchez, Andrés Francisco; Iglesias Jorquera, Elena; Pons Miñano, José Antonio

    2018-04-24

    Splenorenal shunts are a rare cause of hyperammonemia and hepatic encephalopathy in the absence of cirrhosis. We report the case of a woman, who presented hepatic encephalopathy, with a normal functioning graft, after 14 years of liver transplantation, confirmed by liver biopsy.

  19. Optimal Topology and Experimental Evaluation of Piezoelectric Materials for Actively Shunted General Electric Polymer Matrix Fiber Composite Blades

    NASA Technical Reports Server (NTRS)

    Choi, Benjamin B.; Duffy, Kirsten; Kauffman, Jeffrey L.; Kray, Nicholas

    2012-01-01

    NASA Glenn Research Center, in collaboration with GE Aviation, has begun the development of a smart adaptive structure system with piezoelectric (PE) transducers to improve composite fan blade damping at resonances. Traditional resonant damping approaches may not be realistic for rotating frame applications such as engine blades. The limited space in which the blades reside in the engine makes it impossible to accommodate the circuit size required to implement passive resonant damping. Thus, a novel digital shunt scheme has been developed to replace the conventional electric passive shunt circuits. The digital shunt dissipates strain energy through the load resistor on a power amplifier. General Electric (GE) designed and fabricated a variety of polymer matrix fiber composite (PMFC) test specimens. Investigating the optimal topology of PE sensors and actuators for each test specimen has revealed the best PE transducer location for each target mode. Also a variety of flexible patches, which can conform to the blade surface, have been tested to identify the best performing PE patch. The active damping control achieved significant performance at target modes. This work has been highlighted by successful spin testing up to 5000 rpm of subscale GEnx composite blades in Glenn s Dynamic Spin Rig.

  20. Accurate expressions for solar cell fill factors including series and shunt resistances

    NASA Astrophysics Data System (ADS)

    Green, Martin A.

    2016-02-01

    Together with open-circuit voltage and short-circuit current, fill factor is a key solar cell parameter. In their classic paper on limiting efficiency, Shockley and Queisser first investigated this factor's analytical properties showing, for ideal cells, it could be expressed implicitly in terms of the maximum power point voltage. Subsequently, fill factors usually have been calculated iteratively from such implicit expressions or from analytical approximations. In the absence of detrimental series and shunt resistances, analytical fill factor expressions have recently been published in terms of the Lambert W function available in most mathematical computing software. Using a recently identified perturbative relationship, exact expressions in terms of this function are derived in technically interesting cases when both series and shunt resistances are present but have limited impact, allowing a better understanding of their effect individually and in combination. Approximate expressions for arbitrary shunt and series resistances are then deduced, which are significantly more accurate than any previously published. A method based on the insights developed is also reported for deducing one-diode fits to experimental data.

  1. Programmable shunts and headphones: Are they safe together?

    PubMed

    Spader, Heather S; Ratanaprasatporn, Linda; Morrison, John F; Grossberg, Jonathan A; Cosgrove, G Rees

    2015-10-01

    Programmable shunts have a valuable role in the treatment of patients with hydrocephalus, but because a magnet is used to change valve settings, interactions with external magnets may reprogram these shunts. Previous studies have demonstrated the ability of magnetic toys and iPads to erroneously reprogram shunts. Headphones are even more ubiquitous, and they contain an electromagnet for sound projection that sits on the head very close to the shunt valve. This study is the first to look at the magnetic field emissions of headphones and their effect on reprogrammable shunt valves to ascertain whether headphones are safe for patients with these shunts to wear. In this in vitro study of the magnetic properties of headphones and their interactions with 3 different programmable shunts, the authors evaluated Apple earbuds, Beats by Dr. Dre, and Bose QuietComfort Acoustic Noise Cancelling headphones. Each headphone was tested for electromagnetic field emissions using a direct current gaussmeter. The following valves were evaluated: Codman Hakim programmable valve, Medtronic Strata II valve, and Aesculap proGAV. Each valve was tested at distances of 0 to 50 mm (in 5-mm increments) from each headphone. The exposure time at each distance was 1 minute, and 3 trials were performed to confirm results at each valve setting and distance. All 3 headphones generated magnetic fields greater than the respective shunt manufacturer's recommended strength of exposure, but these fields did not persist beyond 5 mm. By 2 cm, the fields levels were below 20 G, well below the Medtronic recommendation of 90 G and the Codman recommendation of 80 G. Because the mechanism for the proGAV is different, there is no recommended gauss level. There was no change in gauss-level emissions by the headphones with changes in frequency and amplitude. Both the Strata and Codman-Hakim valves were reprogrammed by direct contact (distance 0 mm) with the Bose headphones. When a rotation component was added, all 3 headphones reprogrammed the Strata and Codman-Hakim valves at 0 mm. At all distances above 0 mm, the headphones did not affect the shunts. The proGAV valve was not affected by headphones at any distance. Although all the headphones studied generated significant gauss fields at distances less than 5 mm, the programmable valve settings only changed at a distance of 0 mm (i.e., with direct contact). Given the subcutaneous location of the valve, the authors conclude that is highly unlikely that commercially available or customary headphones can contribute to the reprogramming of shunts.

  2. Stimulation of insulin secretion by medium-chain triglycerides in patients with cirrhosis 1

    PubMed Central

    McCullough, Frank S.; Tzagournis, Manuel; Greenberger, Norton J.; Linscheer, Willem G.

    1971-01-01

    Oral medium-chain triglycerides were given to 10 normal volunteers, 12 cirrhotics (group I) without and 28 cirrhotics (group II) with abnormal portal systemic communications (ascites, splenomegaly, oesophageal varices, or surgically-created portacaval shunts). After 30 ml of medium-chain triglyceride oil there was no appreciable change in serum glucose levels in any of the three groups nor in serum insulin levels in the normals and in cirrhotics in group I. However, there was a significant increase in serum insulin levels in the cirrhotic patients in group II. It is suggested that the rise in serum insulin levels after medium-chain triglycerides noted in the cirrhotics with shunts is due to shunting of insulin-containing portal blood around the liver (anatomical shunts) and to a diminished hepatic cell mass capable of extracting insulin (functional shunt). This differential response of serum insulin levels to medium-chain triglycerides may prove to be of value in detecting the presence of abnormal portal systemic communications in cirrhotic patients. PMID:5548559

  3. PLUTO trial protocol: percutaneous shunting for lower urinary tract obstruction randomised controlled trial.

    PubMed

    Kilby, Mark; Khan, Khalid; Morris, Katie; Daniels, Jane; Gray, Richard; Magill, Laura; Martin, Bill; Thompson, Peter; Alfirevic, Zarko; Kenny, Simon; Bower, Sarah; Sturgiss, Stephen; Anumba, Dilly; Mason, Gerald; Tydeman, Graham; Soothill, Peter; Brackley, Karen; Loughna, Pamela; Cameron, Alan; Kumar, Sailesh; Bullen, Phil

    2007-07-01

    The primary objective is to determine whether intrauterine vesicoamniotic shunting for fetal bladder outflow obstruction, compared with conservative, noninterventional care, improves prenatal and perinatal mortality and renal function. The secondary objectives are to determine if shunting for fetal bladder outflow obstruction improves perinatal morbidity, to determine if improvement in outcomes is related to prognostic assessment at diagnosis and, if possible, derive a prognostic risk index and to determine the safety and long-term efficacy of shunting. A multicentre randomised controlled trial (RCT). Fetal medicine units. Pregnant women with singleton, male fetus with isolated lower urinary tract obstruction (LUTO). Following ultrasound diagnosis of LUTO in a male fetus and exclusion of other structural and chromosomal anomalies, participation in the trial will be discussed with the mother and written information given. Consent for participation in the trial will be taken and the mother randomised via the internet to either insertion of a vesicoamniotic shunt or expectant management. During pregnancy, both groups will be followed with regular ultrasound scans looking at viability, renal measurements and amniotic fluid volume. Following delivery, babies will be followed up by paediatric nephrologists/urologists at 4-6 weeks, 12 months and 3 and 5 years to assess renal function via serum creatinine, renal ultrasound and need for dialysis/transplant. The main outcome measures will be perinatal mortality rates and renal function at 4-6 weeks and 12 months measured via serum creatinine, renal ultrasound and need for dialysis/transplant. Wellbeing of Women. ESTIMATED COMPLETION DATE: September 2010. TRIAL ALGORITHM: [flowchart: see text].

  4. Pediatric hydrocephalus: 40-year outcomes in 128 hydrocephalic patients treated with shunts during childhood. Assessment of surgical outcome, work participation, and health-related quality of life.

    PubMed

    Paulsen, Anne Henriette; Lundar, Tryggve; Lindegaard, Karl-Fredrik

    2015-12-01

    Treatment for hydrocephalus has not advanced appreciably since the advent of CSF shunts more than 50 years ago. The outcome for pediatric patients with hydrocephalus has been the object for several studies; however, much uncertainty remains regarding the very long term outcome for these patients. Shunting became the standard treatment for hydrocephalus in Norway during the 1960s, and the first cohorts from this era have now reached middle age. Therefore, the objective of this study was to review surgical outcome, mortality, social outcome, and health-related quality of life in middle-aged patients treated for hydrocephalus during childhood. Data were collected in all patients, age 14 years or less, who required a CSF shunt during the years 1967-1970. Descriptive statistics were assessed regarding patient characteristics, surgical features, social functioning, and work participation. The time and cause of death, if applicable, were also determined. Kaplan-Meier survival estimates were used to determine the overall survival of patients. Information regarding self-perceived health and functional status was assessed using the 36-Item Short Form Health Survey (SF-36) and the Barthel Index score. A total of 128 patients were included in the study, with no patient lost to follow-up. Of the 128 patients in the study, 61 (47.6%) patients died during the 42-45 years of observation. The patients who died belonged to the tumor group (22 patients) and the myelomeningocele group (13 patients). The mortality rate was lowered to 39% if the patients with tumors were excluded. The overall mortality rates at 1, 2, 10, 20, and 40 years from time of initial shunt insertion were 16%, 24%, 31%, 40%, and 48% respectively. The incidence of shunt-related mortality was 8%. The majority of children graduated from a normal school (67%) or from a school specializing in education for physically handicapped children (20%). Self-perceived health was significantly poorer in 6 out of 8 domains assessed by SF-36 as compared with the background population. Functional status among the survivors varied greatly during the follow-up period, but the majority of patients were self-dependent. A total of 56% of the patients were socially independent, and 42% of the patients were employed. Approximately half of the patients are still alive. During the 42-45 year follow-up period, the mortality rate was 48%. Two deaths were due to acute shunt failure, and at least 8% of the deaths were shunt related (probable or late onset). The morbidity in middle-aged individuals treated for pediatric hydrocephalus is considerable. The late mortality rate was low, but not negligible. Twelve patients died during the last 2 decades, 1 of whom died because of acute shunt failure. Although the shunt revision rate was decreasing during the study period, many patients required shunt surgery during adulthood. Forty-one revisions in 21 patients were performed during the last decade. Thus, there is an obvious need for life-long follow-up in these patients.

  5. The CHESS score: a simple tool for early prediction of shunt dependency after aneurysmal subarachnoid hemorrhage.

    PubMed

    Jabbarli, R; Bohrer, A-M; Pierscianek, D; Müller, D; Wrede, K H; Dammann, P; El Hindy, N; Özkan, N; Sure, U; Müller, O

    2016-05-01

    Acute hydrocephalus is an early and common complication of aneurysmal subarachnoid hemorrhage (SAH). However, considerably fewer patients develop chronic hydrocephalus requiring shunt placement. Our aim was to develop a risk score for early identification of patients with shunt dependency after SAH. Two hundred and forty-two SAH individuals who were treated in our institution between January 2008 and December 2013 and survived the initial impact were retrospectively analyzed. Clinical parameters within 72 h after the ictus were correlated with shunt dependency. Independent predictors were summarized into a new risk score which was validated in a subsequent SAH cohort treated between January and December 2014. Seventy-five patients (31%) underwent shunt placement. Of 23 evaluated variables, only the following five showed independent associations with shunt dependency and were subsequently used to establish the Chronic Hydrocephalus Ensuing from SAH Score (CHESS, 0-8 points): Hunt and Hess grade ≥IV (1 point), location of the ruptured aneurysm in the posterior circulation (1 point), acute hydrocephalus (4 points), the presence of intraventricular hemorrhage (1 point) and early cerebral infarction on follow-up computed tomography scan (1 point). The CHESS showed strong correlation with shunt dependency (P = 0.0007) and could be successfully validated in both internal SAH cohorts tested. Patients scoring ≥6 CHESS points had significantly higher risk of shunt dependency (P < 0.0001) than other patients. The CHESS may become a valuable diagnostic tool for early estimation of shunt dependency after SAH. Further evaluation and external validation will be required in prospective studies. © 2016 EAN.

  6. 3T magnetic resonance imaging testing of externally programmable shunt valves

    PubMed Central

    Zabramski, Joseph M.; Preul, Mark C.; Debbins, Josef; McCusker, Daniel J.

    2012-01-01

    Background: Exposure of externally programmable shunt-valves (EPS-valves) to magnetic resonance imaging (MRI) may lead to unexpected changes in shunt settings, or affect the ability to reprogram the valve. We undertook this study to examine the effect of exposure to a 3T MRI on a group of widely used EPS-valves. Methods: Evaluations were performed on first generation EPS-valves (those without a locking mechanism to prevent changes in shunt settings by external magnets other than the programmer) and second generation EPS-valves (those with a locking mechanisms). Fifteen new shunt-valves were divided into five groups of three identical valves each, and then exposed to a series of six simulated MRI scans. After each of the exposures, the valves were evaluated to determine if the valve settings had changed, and whether the valves could be reprogrammed. The study produced 18 evaluations for each line of shunt-valves. Results: Exposure of the first generation EPS-valves to a 3T magnetic field resulted in frequent changes in the valve settings; however, all valves retained their ability to be reprogrammed. Repeated exposure of the second generation EPS-valves has no effect on shunt valve settings, and all valves retained their ability to be interrogated and reprogrammed. Conclusions: Second generation EPS-valves with locking mechanisms can be safely exposed to repeated 3T MRI systems, without evidence that shunt settings will change. The exposure of the first generation EPS-valves to 3T MRI results in frequent changes in shunt settings that necessitate re-evaluation soon after MRI to avoid complications. PMID:22937481

  7. Long-term follow-up of successful treatment for dandy-walker syndrome (DWS).

    PubMed

    Lin, Jun; Liang, Guobiao; Liang, Yong; Kou, Yun

    2015-01-01

    Various managements of Dandy-Walker syndrome (DWS) from open excision of the cysts to CSF diversion have been reported. However, optimal treatment for DWS remains elusive. Cyst fenestration was employed firstly, but failed 15 days after the surgery. Then a ventriculoperitoneal (VP) shunt was inserted and the patient discharged from hospital 13 days after the second surgery. During the 12-year follow-up, CT scanning, MRI, and X-radiation were performed. CT scanning showed that the size of ventricular system gradually returned to normal. MRI revealed similar changes of the ventricular system, and further revealed the development of supratentorial brain. The results of X-radiation during the follow-up years showed that the peritoneal end of the shunt might be already out of the abdominal cavity. Slow refilling of the shunt valve may suggest that the shunt could be probably not functional. The treatment of the patient was successfully, and the abnormal cerebral ventricle system gradually recovered during the 12-year follow-up. Because the patient might be probably independent on the shunt, further choice of the shunt removal should be thinking thoroughly, considering both safety and quality of life for the patient.

  8. Long-term follow-up of successful treatment for dandy-walker syndrome (DWS)

    PubMed Central

    Lin, Jun; Liang, Guobiao; Liang, Yong; Kou, Yun

    2015-01-01

    Background: Various managements of Dandy-Walker syndrome (DWS) from open excision of the cysts to CSF diversion have been reported. However, optimal treatment for DWS remains elusive. Methods: Cyst fenestration was employed firstly, but failed 15 days after the surgery. Then a ventriculoperitoneal (VP) shunt was inserted and the patient discharged from hospital 13 days after the second surgery. During the 12-year follow-up, CT scanning, MRI, and X-radiation were performed. Results: CT scanning showed that the size of ventricular system gradually returned to normal. MRI revealed similar changes of the ventricular system, and further revealed the development of supratentorial brain. The results of X-radiation during the follow-up years showed that the peritoneal end of the shunt might be already out of the abdominal cavity. Slow refilling of the shunt valve may suggest that the shunt could be probably not functional. Conclusion: The treatment of the patient was successfully, and the abnormal cerebral ventricle system gradually recovered during the 12-year follow-up. Because the patient might be probably independent on the shunt, further choice of the shunt removal should be thinking thoroughly, considering both safety and quality of life for the patient. PMID:26770421

  9. Hypoxia and GABA shunt activation in the pathogenesis of Alzheimer's disease.

    PubMed

    Salminen, Antero; Jouhten, Paula; Sarajärvi, Timo; Haapasalo, Annakaisa; Hiltunen, Mikko

    2016-01-01

    We have previously observed that the conversion of mild cognitive impairment to definitive Alzheimer's disease (AD) is associated with a significant increase in the serum level of 2,4-dihydroxybutyrate (2,4-DHBA). The metabolic generation of 2,4-DHBA is linked to the activation of the γ-aminobutyric acid (GABA) shunt, an alternative energy production pathway activated during cellular stress, when the function of Krebs cycle is compromised. The GABA shunt can be triggered by local hypoperfusion and subsequent hypoxia in AD brains caused by cerebral amyloid angiopathy. Succinic semialdehyde dehydrogenase (SSADH) is a key enzyme in the GABA shunt, converting succinic semialdehyde (SSA) into succinate, a Krebs cycle intermediate. A deficiency of SSADH activity stimulates the conversion of SSA into γ-hydroxybutyrate (GHB), an alternative route from the GABA shunt. GHB can exert not only acute neuroprotective activities but unfortunately also chronic detrimental effects which may lead to cognitive impairment. Subsequently, GHB can be metabolized to 2,4-DHBA and secreted from the brain. Thus, the activation of the GABA shunt and the generation of GHB and 2,4-DHBA can have an important role in the early phase of AD pathogenesis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Combined intracranial pressure monitoring and cerebrospinal fluid infusion study to guide management of slit ventricle syndrome.

    PubMed

    Hart, Michael Gavin; Czosnyka, Marek; Czosnyka, Zofia Helena; Fernandes, Helen Marie

    2013-01-01

    Slit ventricle syndrome remains a complex entity presenting a considerable challenge to treat successfully. This study aims to demonstrate the application of dual intracranial pressure (ICP) and infusion studies together with the novel shunt occlusion test in both a diagnostic and therapeutic role. An 8-year-old child had aqueduct stenosis treated with a ventriculoperitoneal shunt (medium-pressure valve). The presentation was of headaches with papilloedema. Imaging with both computed tomography and magnetic resonance imaging revealed slit ventricles. Initially a shunt exploration revealed distal obstruction that was treated together with insertion of a paediatric strata II regular valve; however, the child continued to deteriorate. Overnight ICP monitoring revealed dramatically raised ICP with poor compensatory reserve. Intra-operative infusion study revealed a shunt that was patent distally but with proximal obstruction. A subtemporal decompression ipsilateral to the shunt was performed together with adjustment of the paediatric strata II regular valve to 2.5 in order to prevent overdrainage. This led to normalisation of ICP, resolution of papilloedema and symptomatic improvement. We demonstrate how combined ICP monitoring and shunt infusion studies can be used to help guide management. Unilateral subtemporal decompressions and preventing shunt overdrainage can result in normalisation of ICP and cerebrospinal fluid dynamics.

  11. Surgical strategy according to the anatomical types of congenital portosystemic shunts in children.

    PubMed

    Matsuura, Toshiharu; Takahashi, Yoshiaki; Yanagi, Yusuke; Yoshimaru, Koichiro; Yamamura, Kenichiro; Morihana, Eiji; Nagata, Hazumu; Uike, Kiyoshi; Takada, Hidetoshi; Taguchi, Tomoaki

    2016-12-01

    Congenital portosystemic shunts (CPSS) with intrahepatic portal vein (IHPV) hypoplasia or absence cause encephalopathy or pulmonary hypertension (PH). Acute shunt closure may result in postoperative portal hypertension. The aim of this study was to propose a surgical strategy according to the anatomical types of CPSS and IHPV. Twenty-three CPSS patients were diagnosed from1990 to 2015. All patients were evaluated by computed tomography, angiography, and PV pressure monitoring under a shunt occlusion test. CPSS were categorized into 5 types according to the anatomical shunt location. The median age at diagnosis was 34months. Three of 23 total patients, who had an extrahepatic portosystemic shunt with a hypoplastic IHPV, died before treatment initiation because of severe PH. Fourteen cases received surgical or interventional treatment at the median age of 5years. A total of 6 cases received surgical therapy, including liver transplants for 2 absent IHPV cases. The remaining 8 cases received interventional coiling. All shunt ligations were successfully accomplished in 1-stage ligation without any complications. After the treatment, the hypoplastic IHPV gradually enlarged with an efficient portal inflow. A precise pretreatment anatomical evaluation of CPSS and IHPV types is mandatory for the selection of surgical treatment. Diagnostic study - level II and treatment study - level III. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Ventricular-subcutaneous shunt for the treatment of experimental hydrocephalus in young rats: technical note.

    PubMed

    Santos, Marcelo Volpon; Garcia, Camila Araujo Bernardino; Jardini, Evelise Oliveira; Romeiro, Thais Helena; da Silva Lopes, Luiza; Machado, Hélio Rubens; de Oliveira, Ricardo Santos

    2016-08-01

    Hydrocephalus is a complex disease that affects cerebrospinal fluid (CSF) dynamics and is very common in children. To this date, CSF shunting is still the standard treatment for childhood hydrocephalus, but, nevertheless, the effects of such an operation on the developing brain are widely unknown. To help overcome this, experimental models of CSF shunts are surely very useful tools. The objective of this study was to describe a feasible and reliable technique of an adapted ventricular-subcutaneous shunt for the treatment of kaolin-induced hydrocephalus in young rats. We developed a ventricular-subcutaneous shunt (VSCS) technique which was used in 31 Wistar young rats with kaolin-induced hydrocephalus. Hydrocephalus was induced at 7 days of age, and shunt implantation was performed 7 days later. Our technique used a 0.7-mm gauge polypropylene catheter tunneled to a subcutaneous pocket created over the animal's back and inserted into the right lateral ventricle. All animals were sacrificed 14 days after shunt insertion. Twenty-four rats survived and remained well until the study was ended. No major complications were seen. Their weight gain went back to normal. They all underwent ambulatory behavioral testing prior and after VSCS, which showed improvement in their motor skills. We have also obtained magnetic resonance (MR) scans of 16 pups confirming reduction of ventricular size after shunting and indicating effective treatment. Histopathological analysis of brain samples before and after shunting showed reversion of ependymal and corpus callosum disruption, as well as fewer reactive astrocytes in shunted animals. An experimental CSF shunt technique was devised. Excessive CSF of hydrocephalic rats is diverted into the subcutaneous space where it can be resorbed. This technique has a low complication rate and is effective. It might be applied to various types of experimental studies involving induction and treatment of hydrocephalus.

  13. Association between right-to-left shunts and brain lesions in sport divers.

    PubMed

    Gerriets, Tibo; Tetzlaff, Kay; Hutzelmann, Alfred; Liceni, Thomas; Kopiske, Gerrit; Struck, Niklas; Reuter, Michael; Kaps, Manfred

    2003-10-01

    Recent studies suggest that healthy sport divers may develop clinically silent brain damage, based on the association between a finding of multiple brain lesions on MRI and the presence of right-to-left shunt, a pathway for venous gas bubbles to enter the arterial system. We performed echocontrast transcranial Doppler sonography in 42 sport divers to determine the presence of a right-to-left shunt. Cranial MRI was carried out using a 1.5 T magnet. A lesion was counted if it was hyperintense on both T2-weighted and T2-weighted fluid attenuated inversion recovery sequences. To test the hypothesis that the occurrence of postdive arterial gas emboli is related to brain lesions on MRI, we measured postdive intravascular bubbles in a subset of 15 divers 30 min after open water scuba dives. Echocontrast transcranial Doppler sonography revealed a right-to-left shunt in 16 of the divers (38%). Only one hyperintensive lesion of the central white matter was found and that was in a diver with no evidence of a right-to-left shunt. Postdive arterial gas emboli were detected in 3 out of 15 divers; they had a right-to-left shunt, but no pathologic findings on cranial magnetic resonance imaging. Our data support the theory that right-to-left shunts can serve as a pathway for venous gas bubbles into the arterial circulation. However, we could not confirm an association between brain lesions and the presence of a right-to-left shunt in sport divers.

  14. Is a combination of Tc-SPECT or perfusion weighted magnetic resonance imaging with spinal tap test helpful in the diagnosis of normal pressure hydrocephalus?

    PubMed

    Hertel, F; Walter, C; Schmitt, M; Mörsdorf, M; Jammers, W; Busch, H P; Bettag, M

    2003-04-01

    The aim of this study was to evaluate the combination of spinal tap test (STT) with cerebral perfusion measurement assessed either by Tc-bicisate-SPECT (Tc-SPECT) or perfusion weighted MRI (pwMRI), or both, for a better preoperative selection of promising candidates for shunt operations in suspected idiopathic normal pressure hydrocephalus. 27 consecutive patients were examined with a standard clinical protocol (assessed by the Homburg Hydrocephalus Scale (HHS)) as well as with 99m Tc-bicisate-SPECT (n=27) or additionally by pwMRI (n=12) before and after STT. The results of these examinations were compared preoperatively for each patient and correlated with postoperative clinical outcome after shunt surgery. Nine patients showed both, a clinical improvement, and increased cerebral perfusion after STT. They underwent shunt surgery with good to excellent results. In another nine patients increasing cerebral perfusion was detected although they did not show a clear clinical improvement after STT. Six of them also received a shunt operation with good to excellent outcome. Three patients of the last group could have an operation. Nine patients did not show any clinical improvement or any kind of increasing cerebral perfusion after STT. Therefore, they did not undergo surgery. The results of SPECT and pwMRI correlated in 92 % of the patients (11 of 12). It is concluded that a combination of clinical assessment with SPECT or pwMRI is helpful in the preoperative selection of patients for shunting procedures with suspected NPH syndrome. This combination is a minimal invasive and objective test modality that is superior to STT alone. Further studies are necessary for a comparison of the described imaging techniques with different diagnostic tests in this difficult field of cerebral disease.

  15. Contemporary survival of patients with pulmonary arterial hypertension and congenital systemic to pulmonary shunts

    PubMed Central

    Chungsomprasong, Paweena; Bositthipichet, Densiri; Ketsara, Salisa; Titaram, Yuttapon; Chanthong, Prakul; Kanjanauthai, Supaluck

    2018-01-01

    Objective To compare survival of patients with newly diagnosed pulmonary arterial hypertension associated with congenital heart disease (PAH-CHD) according to various clinical classifications with classifications of anatomical-pathophysiological systemic to pulmonary shunts in a single-center cohort. Methods All prevalent cases of PAH-CHD with hemodynamic confirmation by cardiac catheterization in 1995–2015 were retrospectively reviewed. Patients who were younger than three months of age, or with single ventricle following surgery were excluded. Baseline characteristics and clinical outcomes were retrieved from the database. The survival analysis was performed at the end of 2016. Prognostic factors were identified using multivariate analysis. Results A total of 366 consecutive patients (24.5 ± 17.6 years of age, 40% male) with PAH-CHD were analyzed. Most had simple shunts (85 pre-tricuspid, 105 post-tricuspid, 102 combined shunts). Patients with pre-tricuspid shunts were significantly older at diagnosis in comparison to post-tricuspid, combined, and complex shunts. Clinical classifications identified patients as having Eisenmenger syndrome (ES, 26.8%), prevalent left to right shunt (66.7%), PAH with small defect (3%), or PAH following defect correction (3.5%). At follow-up (median = 5.9 years; 0.1–20.7 years), no statistically significant differences in survival rate were seen among the anatomical-pathophysiological shunts (p = 0.1). Conversely, the clinical classifications revealed that patients with PAH-small defect had inferior survival compared to patients with ES, PAH post-corrective surgery, or PAH with prevalent left to right shunt (p = 0.01). Significant mortality risks were functional class III, age < 10 years, PAH-small defect, elevated right atrial pressure > 15 mmHg, and baseline PVR > 8 WU•m.2 Conclusion Patients with PAH-CHD had a modest long-term survival. Different anatomical-pathophysiological shunts affect the natural presentation, while clinical classifications indicate treatment strategies and survival. Contemporary therapy improves survival in deliberately selected patients. PMID:29664959

  16. Underwater energy harvesting from a turbine hosting ionic polymer metal composites

    NASA Astrophysics Data System (ADS)

    Cellini, Filippo; Pounds, Jason; Peterson, Sean D.; Porfiri, Maurizio

    2014-08-01

    In this study, we explore the possibility of energy harvesting from fluid flow through a turbine hosting ionic polymer metal composites (IPMCs). Specifically, IPMC harvesters are embedded in the blades of a small-scale vertical axis water turbine to convert flow kinetics into electrical power via low-frequency flow-induced IPMC deformations. An in-house fabricated Savonius-Darrieus hybrid active turbine with three IPMCs is tested in a laboratory water tunnel to estimate the energy harvesting capabilities of the device as a function of the shunting electrical load. The turbine is shown to harvest a few nanowatt from a mean flow of 0.43\\;m\\;{{s}^{-1}} for shunting resistances in the range 100-1000\\;\\Omega . To establish a first understanding of the energy harvesting device, we propose a quasi-static hydroelastic model for the bending of the IPMCs and we utilize a black-box model to study their electromechanical response.

  17. Imaging of patent foramen ovale with 64-section multidetector CT.

    PubMed

    Saremi, Farhood; Channual, Stephanie; Raney, Aidan; Gurudevan, Swaminatha V; Narula, Jagat; Fowler, Steven; Abolhoda, Amir; Milliken, Jeffrey C

    2008-11-01

    To investigate the feasibility of 64-section multidetector computed tomography (CT) by using CT angiography (a) to demonstrate anatomic detail of the interatrial septum pertinent to the patent foramen ovale (PFO), and (b) to visually detect left-to-right PFO shunts and compare these findings in patients who also underwent transesophageal echocardiography (TEE). In this institutional review board-approved HIPAA-compliant study, electrocardiographically gated coronary CT angiograms in 264 patients (159 men, 105 women; mean age, 60 years) were reviewed for PFO morphologic features. The length and diameter of the opening of the PFO tunnel, presence of atrial septal aneurysm (ASA), and PFO shunts were evaluated. A left-to-right shunt was assigned a grade according to length of contrast agent jet (grade 1, 1 cm to 2 cm; grade 3, >2 cm). In addition, 23 patients who underwent both modalities were compared (Student t test and linear regression analysis). A difference with P < .05 was significant. A flap valve, seen in 101 (38.3%) patients, was patent at the entry into the right atrium (PFO) in 62 patients (61.4% of patients with flap valve, 23.5% of total patients). A left-to-right shunt was detected in 44 (16.7% of total) patients (grade 1, 61.4%; grade 2, 34.1%; grade 3, 4.5%). No shunt was seen in patients without a flap valve. Mean length of PFO tunnel was 7.1 mm in 44 patients with a shunt and 12.1 mm in 57 patients with a flap valve without a shunt (P < .0001). In patients with a tunnel length of 6 mm or shorter, 92.6% of the shunts were seen. ASA was seen in 11 (4.2%) patients; of these patients, a shunt was seen in seven (63.6%). In 23 patients who underwent CT angiography and TEE, both modalities showed a PFO shunt in seven. Multidetector CT provides detailed anatomic information about size, morphologic features, and shunt grade of the PFO. Shorter tunnel length and septal aneurysms are frequently associated with left-to-right shunts in patients with PFO. (c) RSNA, 2008.

  18. [Normal pressure hydrocephalus: prognostic value of height in patients treated with an identical shunt system].

    PubMed

    Aguas, Jesús; Rodrigo, Victor; Estupiñan, Francisco; Nogues, Pere; Villalba, Gloria; Villagrasa, Javier; Caral, Luis

    2013-01-01

    Normal pressure hydrocephalus (NPH) is a clinical entity frequently managed by means of a cerebrospinal fluid shunt. Hydrodynamic hypotheses consider hydrostatic pressure (as well as height) a very important variable for shunt system function. However, we did not find empirical studies supporting the influence of height on clinical response in the literature. Our objective was to study the prognostic value of height, as a variable related to hydrostatic pressure, when an identical shunt system is used. A prospective series of 61 idiopathic NPH cases was analyzed. All cases were shunted by means of a ventricle-peritoneal system with a 100mmH2O opening pressure valve. Anthropometric, clinical, radiological and pressure variables were registered, as well as delay for treatment, improvement and complications. 78.7% of cases improved after shunting. This group of patients was significantly taller (P=.005) than the group without response (median value 165cm versus 152cm). There was also a significant correlation between height and ventricular size decrease after the shunt. In our series opening valve pressure was a constant (100mmHg) and we could consequently focus on the effect of hydrostatic pressure (height). Moreover, we found a positive predictive value for taller patients, probably because we had selected an opening pressure especially suitable for them. Current gravitational valve shunt systems also recommend considering patient height when customising the system. Our study empirically supports this idea. Copyright © 2012 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  19. Postprandial hyperinsulinaemic hypoglycaemia secondary to a congenital portosystemic shunt.

    PubMed

    Senniappan, Senthil; Pitt, Katherine; Shah, Pratik; Arya, Ved; Jaiswal, Sanjay; Haddad, Munther; Hind, Jonathan; Dhawan, Anil; Davenport, Mark; Hussain, Khalid

    2015-01-01

    Portosystemic shunts (PSS) are abnormal vascular connections between the portal vein or its tributaries and the systemic vein that allow mesenteric blood to reach the systemic circulation without first passing through the liver. PSS can be associated with various syndromes and can lead to serious complications. We report a rare case of a child with PSS and recurrent hypoglycaemia. A 20-month-old girl with Down's syndrome presented with recurrent hypoglycaemic episodes. She had multiple anomalies including a ventricular septal defect, oesophageal atresia and tracheo-esophageal fistula, gastro-oesophageal reflux, and conjugated hyperbilirubinaemia. The initial investigations suggested hyperinsulinaemic hypoglycaemia (HH). She did not respond to diazoxide. An oral glucose tolerance test suggested postprandial HH. Further vascular imaging showed a side-to-side portocaval shunt (Abernethy malformation) with relative hypoperfusion of the liver. Hypoglycaemia resolved following surgical closure of the portocaval shunt. PSS can rarely be associated with HH, possibly due to lack of insulin degradation in the liver. Surgical closure of the shunt resolves the hypoglycaemia. © 2015 S. Karger AG, Basel.

  20. Evidence of an application of a variable MEMS capacitive sensor for detecting shunt occlusions

    NASA Astrophysics Data System (ADS)

    Apigo, David J.; Bartholomew, Philip L.; Russell, Thomas; Kanwal, Alokik; Farrow, Reginald C.; Thomas, Gordon A.

    2017-04-01

    A sensor was tested subdural and in vitro, simulating a supine infant with a ventricular-peritoneal shunt and controlled occlusions. The variable MEMS capacitive device is able to detect and forecast blockages, similar to early detection procedures in cancer patients. For example, with gradual occlusion development over a year, the method forecasts a danger over one month ahead of blockage. The method also distinguishes between ventricular and peritoneal occlusions. Because the sensor provides quantitative data on the dynamics of the cerebrospinal fluid, it can help test new therapies and work toward understanding hydrocephalus as well as idiopathic normal pressure hydrocephalus. The sensor appears to be a substantial advance in treating brain injuries treated with shunts and has the potential to bring significant impact in a clinical setting.

  1. [Intracranial pressure monitoring and CSF dynamics in patients with neurological disorders: indications and practical considerations].

    PubMed

    Poca, M; Sahuquillo, J

    2001-01-01

    The study of cerebrospinal fluid (CSF) dynamics is central to the diagnosis of adult chronic hydrocephalus (ACH). At present, many neurology and neurosurgery departments use one or more tests to guide diagnosis of this syndrome and to predict patient response to shunting. In specialised centres, the study of CSF dynamics is combined with continuous intracranial pressure (ICP) monitoring. Determination of several variables of CSF dynamics and definitions of qualitative and quantitative characteristics of ICP can be used to establish whether the hydrocephalus is active, compensated or arrested. CSF dynamics and ICP monitoring can also be used to check the correct functioning of the shunt and can be of use in the clinical management of patients with pseudotumor cerebri. Moreover, ICP monitoring is used to guide the treatment of several acute neurological processes. The aim of this review is to describe the fundamentals of CSF dynamics studies and the bases of continuous ICP monitoring. The advantages and disadvantages of several hydrodynamic tests that can be performed by lumbar puncture, as well as the normal and abnormal characteristics of an ICP recording, are discussed.

  2. Experimental Percutaneous Extrahepatic Portacaval Shunt Creation by Transjugular Approach in Swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seong, Chang Kyu; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu; Uchida, Barry T.

    2005-06-15

    The purpose of the study was to evaluate the feasibility of the creation of a percutaneous extrahepatic portacaval shunt (PEPS) in swine by a transjugular approach and to find a suitable stent-graft to use in PEPS. In 12 swine, the extrahepatic portal vein (PV) was entered from the inferior vena cava (IVC) by a needle system introduced from the transjugular approach. A catheter introduced through the transhepatic approach served as a target. Five types of stent-graft consisting of homemade Z stents and a polytetrafluoethylene cover were explored for PEPS creation. Eight animals had follow-up venograms up to 6 weeks ormore » until the shunt became severely stenotic. Gross and histologic examinations were performed after the final follow-up venography. The PV punctures and stent-graft placement were difficult, but the PEPS was established in all animals. In four animals, the stent-graft failed to adequately cover the tract, causing severe hemorrhage. Only two shunts remained patent up to 6 weeks. The other shunts exhibited severe stenosis or occlusion. At gross examination, all shunts traversed the liver parenchyma of the caudate lobe surrounding the IVC. The extravascular PEPS portion was 4 mm to 2 cm long. All shunts entered the PV close to the splenomesenteric junction and exhibited neointimal formation. Shunt stenoses were caused by neointimal hyperplasia and occlusions by a superimposed thrombus. PEPS can be created by the transjugular approach in swine, but only the PV shunt entrance is extrahepatic. None of the tested rigid stent-grafts were suitable for PEPS creation. A short flexible stent-graft with flanged ends is suggested for further exploration.« less

  3. Analysis of ProSEDS Test of Bare-Tether Collection

    NASA Technical Reports Server (NTRS)

    Sanmartin, J. R.; Lorenzini, E. C.; Estes, R. D.; Charro, M.; Cosmo, M. L.

    2003-01-01

    NASA's tether experiment ProSEDS will be placed in orbit on board a Delta-II rocket to test bare-tether electron collection, deorbiting of the rocket second stage, and the system dynamic stability. ProSEDS performance will vary because ambient conditions change along the orbit and tether-circuit bulk elements at the cathodic end follow the step-by-step sequence for the current cycles of operating modes (open-circuit, shunt and resistor modes for primary cycles; shunt and battery modes for secondary cycles). In this work we discuss expected ProSEDS values of the ratio L,/L*, which jointly with cathodic bulk elements determines bias and current tether profiles; L, is tether length, and L* (changing with tether temperature and ionospheric plasma density and magnetic field) is a characteristic length gauging ohmic versus baretether collection impedances. We discuss how to test bare-tether electron collection during primary cycles, using probe measurements of plasma density, measurements of cathodic current in resistor and shunt modes, and an estimate of tether temperature based on ProSEDS orbital position at the particular cycle concerned. We discuss how a temperature misestimate might occasionally affect the test of bare-tether collection, and how introducing the battery mode in some primary cycles, for an additional current measurement, could obviate the need of a temperature estimate. We also show how to test bare-tether collection by estimating orbit-decay rate from measurements of cathodic current for the shunt and battery modes of secondary cycles.

  4. Reproducibility of right-to-left shunt quantification using transthoracic contrast echocardiography in hereditary haemorrhagic telangiectasia.

    PubMed

    Vorselaars, V M M; Velthuis, S; Huitema, M P; Hosman, A E; Westermann, C J J; Snijder, R J; Mager, J J; Post, M C

    2018-04-01

    Transthoracic contrast echocardiography (TTCE) is recommended for screening of pulmonary arteriovenous malformations (PAVMs) in hereditary haemorrhagic telangiectasia. Shunt quantification is used to find treatable PAVMs. So far, there has been no study investigating the reproducibility of this diagnostic test. Therefore, this study aimed to describe inter-observer and inter-injection variability of TTCE. We conducted a prospective single centre study. We included all consecutive persons screened for presence of PAVMs in association with hereditary haemorrhagic telangiectasia in 2015. The videos of two contrast injections per patient were divided and reviewed by two cardiologists blinded for patient data. Pulmonary right-to-left shunts were graded using a three-grade scale. Inter-observer and inter-injection agreement was calculated with κ statistics for the presence and grade of pulmonary right-to-left shunts. We included 107 persons (accounting for 214 injections) (49.5% male, mean age 45.0 ± 16.6 years). A pulmonary right-to-left shunt was present in 136 (63.6%) and 131 (61.2%) injections for observer 1 and 2, respectively. Inter-injection agreement for the presence of pulmonary right-to-left shunts was 0.96 (95% confidence interval (CI) 0.9-1.0) and 0.98 (95% CI 0.94-1.00) for observer 1 and 2, respectively. Inter-injection agreement for pulmonary right-to-left shunt grade was 0.96 (95% CI 0.93-0.99) and 0.95 (95% CI 0.92-0.98) respectively. There was disagreement in right-to-left shunt grade between the contrast injections in 11 patients (10.3%). Inter-observer variability for presence and grade of the pulmonary right-to-left shunt was 0.95 (95% CI 0.91-0.99) and 0.97 (95% CI 0.95-0.99) respectively. TTCE has an excellent inter-injection and inter-observer agreement for both the presence and grade of pulmonary right-to-left shunts.

  5. Glycolysis without pyruvate kinase in Clostridium thermocellum

    DOE PAGES

    Olson, Daniel G.; Horl, Manuel; Fuhrer, Tobias; ...

    2016-12-01

    The metabolism of Clostridium thermocellum is notable in that it assimilates sugar via the EMP pathway but does not possess a pyruvate kinase enzyme. In the wild type organism, there are three proposed pathways for conversion of phosphoenolpyruvate (PEP) to pyruvate, which differ in their cofactor usage. One path uses pyruvate phosphate dikinase (PPDK), another pathway uses the combined activities of PEP carboxykinase (PEPCK) and oxaloacetate decarboxylase (ODC). Yet another pathway, the malate shunt, uses the combined activities of PEPCK, malate dehydrogenase and malic enzyme. First we showed that there is no flux through the ODC pathway by enzyme assay.more » Flux through the remaining two pathways (PPDK and malate shunt) was determined by dynamic 13C labeling. In the wild-type strain, the malate shunt accounts for about 33 ± 2% of the flux to pyruvate, with the remainder via the PPDK pathway. Deletion of the ppdk gene resulted in a redirection of all pyruvate flux through the malate shunt. Lastly, this provides the first direct evidence of the in-vivo function of the malate shunt.« less

  6. Long-term serum bile acid concentrations in 51 dogs after complete extrahepatic congenital portosystemic shunt ligation.

    PubMed

    Bristow, P; Tivers, M; Packer, R; Brockman, D; Ortiz, V; Newson, K; Lipscomb, V

    2017-08-01

    To report the long-term bile acid stimulation test results for dogs that have undergone complete suture ligation of a single congenital extrahepatic portosystemic shunt. Data were collected from the hospital records of all dogs that had undergone a complete suture ligation of a single congenital extrahepatic portosystemic shunt. Owners were invited to return to the referral centre or their local veterinarian for repeat serum bile acid measurement. Dogs diagnosed with idiopathic epilepsy and undergoing bile acid stimulation tests were used as a comparison population. Fifty-one study dogs were included, with a mean follow-up time of 62 months. 48 dogs had no evidence of multiple acquired shunts and a significant reduction in the pre- and post-prandial serum bile acid concentrations at long-term follow-up compared with pre-operative measurements. Pre- and post-prandial serum bile acids were statistically significantly greater for dogs that had undergone a full ligation (with no evidence of multiple acquired shunts) at all time points compared to the control dogs (P<0·001 for all comparisons). The results suggest that in dogs treated with complete suture ligation mild increases in serum bile acids are not clinically relevant if there are no physical examination abnormalities, a normal body condition score and no relapse in clinical signs. © 2017 British Small Animal Veterinary Association.

  7. Aberrant Gene Expression in Dogs with Portosystemic Shunts

    PubMed Central

    Grinwis, Guy C. M.; Kummeling, Anne; van Gils, Ingrid H. M.; Koerkamp, Marian J. A. Groot.; van Leenen, Dik; Holstege, Frank C. P.; Penning, Louis C.; Rothuizen, Jan; Leegwater, Peter A. J.; Spee, Bart

    2013-01-01

    Congenital portosystemic shunts are developmental anomalies of the splanchnic vascular system that cause portal blood to bypass the liver. Large-breed dogs are predisposed for intrahepatic portosystemic shunts (IHPSS) and small-breed dogs for extrahepatic portosystemic shunts (EHPSS). While the phenotype resulting from portal bypass of the liver of the two types of shunt is identical, the genotype and molecular pathways involved are probably different. The aim of this study was to gain insight into the pathways involved in the different types of portosystemic shunting. Microarray analysis of mRNA expression in liver tissue from dogs with EHPSS and IHPSS revealed that the expression of 26 genes was altered in either IHPSS or EHPSS samples compared with that in liver samples from control dogs. Quantitative real-time PCR of these genes in 14 IHPSS, 17 EHPSS, and 8 control liver samples revealed a significant differential expression of ACBP, CCBL1, GPC3, HAMP, PALLD, VCAM1, and WEE1. Immunohistochemistry and Western blotting confirmed an increased expression of VCAM1 in IHPSS but its absence in EHPSS, an increased WEE1 expression in IHPSS but not in EHPSS, and a decreased expression of CCBL1 in both shunt types. Regarding their physiologic functions, these findings may indicate a causative role for VCAM1 in IHPSS and WEE1 for IHPSS. CCBL1 could be an interesting candidate to study not yet elucidated aspects in the pathophysiology of hepatic encephalopathy. PMID:23451256

  8. Nuclear magnetic resonance studies of the regulation of the pentose phosphate pathway

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolo, N.R.

    1991-11-01

    The goal of this work is to investigate the potential for and limitations of in vivo nuclear magnetic resonance (NMR) spectroscopy for quantitation of glucose flux through the pentose phosphate pathway (shunt). Interest in the shunt is motivated by the possibility that its activity may be greatly increased in cancer and in the pathological states of cardiac and cerebral ischemia. The ability to dynamically monitor flux through the pentose shunt can give new knowledge about metabolism in pathological states. {sup 13}C NMR spectroscopy was used to monitor shunt activity by determination of the ratios of ({sup 13}C-4) to ({sup 13}C-5)-glutamate,more » ({sup 13}C-3) to ({sup 13}C-2)-alanine or ({sup 13}C-3) to ({sup 13}C-2)-lactate produced when ({sup 13}C-2)-glucose is infused. These methods provide measures of the effect of oxidative stresses on shunt activity in systems ranging from cell free enzyme-substrate preparations to cell suspensions and whole animals. In anaerobic cell free preparations, the fraction of glucose flux through the shunt was monitored with a time resolution of 3 minutes. This work predicts the potential for in vivo human studies of pentose phosphate pathway activity based on the mathematical simulation of the {sup 13}C fractional enrichments of C4 and C5-glutamate as a function of shunt activity and on the signal-to- noise ratio acquired in {sup 13}C NMR human studies from the current literature.« less

  9. Nuclear magnetic resonance studies of the regulation of the pentose phosphate pathway

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolo, Nicolas Robin

    1991-11-01

    The goal of this work is to investigate the potential for and limitations of in vivo nuclear magnetic resonance (NMR) spectroscopy for quantitation of glucose flux through the pentose phosphate pathway (shunt). Interest in the shunt is motivated by the possibility that its activity may be greatly increased in cancer and in the pathological states of cardiac and cerebral ischemia. The ability to dynamically monitor flux through the pentose shunt can give new knowledge about metabolism in pathological states. 13C NMR spectroscopy was used to monitor shunt activity by determination of the ratios of [ 13C-4] to [ 13C-5]-glutamate, [more » 13C-3] to [ 13C-2]-alanine or [ 13C-3] to [ 13C-2]-lactate produced when [ 13C-2]-glucose is infused. These methods provide measures of the effect of oxidative stresses on shunt activity in systems ranging from cell free enzyme-substrate preparations to cell suspensions and whole animals. In anaerobic cell free preparations, the fraction of glucose flux through the shunt was monitored with a time resolution of 3 minutes. This work predicts the potential for in vivo human studies of pentose phosphate pathway activity based on the mathematical simulation of the 13C fractional enrichments of C4 and C5-glutamate as a function of shunt activity and on the signal-to- noise ratio acquired in 13C NMR human studies from the current literature.« less

  10. Congenital portosystemic shunt: characterization of a multisystem disease.

    PubMed

    Sokollik, Christiane; Bandsma, Robert H J; Gana, Juan C; van den Heuvel, Meta; Ling, Simon C

    2013-06-01

    Congenital portosystemic shunts (CPSSs) are rare but increasingly recognized as a cause of important multisystem morbidity. We present new cases and a systematic literature review and propose an algorithm for the identification and care of affected patients. We reviewed the charts of consecutive patients seen in our pediatric liver clinic between 2003 and 2010 and systematically reviewed the literature of cases with CPSS. We identified 316 published cases and 12 patients in our own clinic. Of the published cases (177 male), 185 had an extrahepatic and 131 an intrahepatic portosystemic shunt. Diagnosis was made at any age, from prenatal to late adulthood. Cardiac anomalies were found in 22% of patients. The main complications were hyperammonemia/neurological abnormalities (35%), liver tumors (26%), and pulmonary hypertension or hepatopulmonary syndrome (18%). The spectrum of neurological involvement ranged from changes in brain imaging, subtle abnormalities on neuropsychological testing, through learning disabilities to overt encephalopathy. Spontaneous shunt closure occurred mainly in infants with intrahepatic shunts. Therapeutic interventions included shunt closure by surgery or interventional radiology techniques (35%) and liver transplantation (10%) leading to an improvement of symptoms in the majority. These findings mirror the observations in our own patients. In this largest review of the reported clinical experience, we identify that children with CPSS may present with otherwise unexplained developmental delay, encephalopathy, pulmonary hypertension, hypoxemia, or liver tumors. When CPSS is diagnosed, children should be screened for all of these complications. Spontaneous closure of intrahepatic shunts may occur in infancy. Closure of the shunt is indicated in symptomatic patients and is associated with a favorable outcome.

  11. Practice guideline: Idiopathic normal pressure hydrocephalus: Response to shunting and predictors of response

    PubMed Central

    Halperin, John J.; Kurlan, Roger; Schwalb, Jason M.; Cusimano, Michael D.; Gronseth, Gary; Gloss, David

    2015-01-01

    Objective: We evaluated evidence for utility of shunting in idiopathic normal pressure hydrocephalus (iNPH) and for predictors of shunting effectiveness. Methods: We identified and classified relevant published studies according to 2004 and 2011 American Academy of Neurology methodology. Results: Of 21 articles, we identified 3 Class I articles. Conclusions: Shunting is possibly effective in iNPH (96% chance subjective improvement, 83% chance improvement on timed walk test at 6 months) (3 Class III). Serious adverse event risk was 11% (1 Class III). Predictors of success included elevated Ro (1 Class I, multiple Class II), impaired cerebral blood flow reactivity to acetazolamide (by SPECT) (1 Class I), and positive response to either external lumbar drainage (1 Class III) or repeated lumbar punctures. Age may not be a prognostic factor (1 Class II). Data are insufficient to judge efficacy of radionuclide cisternography or aqueductal flow measurement by MRI. Recommendations: Clinicians may choose to offer shunting for subjective iNPH symptoms and gait (Level C). Because of significant adverse event risk, risks and benefits should be carefully weighed (Level B). Clinicians should inform patients with iNPH with elevated Ro and their families that they have an increased chance of responding to shunting compared with those without such elevation (Level B). Clinicians may counsel patients with iNPH and their families that (1) positive response to external lumbar drainage or to repeated lumbar punctures increases the chance of response to shunting, and (2) increasing age does not decrease the chance of shunting being successful (both Level C). PMID:26644048

  12. Non-Invasive Assessment of Liver Function

    PubMed Central

    Helmke, Steve; Colmenero, Jordi; Everson, Gregory T.

    2015-01-01

    Purpose of review It is our opinion that there is an unmet need in Hepatology for a minimally- or noninvasive test of liver function and physiology. Quantitative liver function tests (QLFTs) define the severity and prognosis of liver disease by measuring the clearance of substrates whose uptake or metabolism is dependent upon liver perfusion or hepatocyte function. Substrates with high affinity hepatic transporters exhibit high “first-pass” hepatic extraction and their clearance measures hepatic perfusion. In contrast, substrates metabolized by the liver have low first-pass extraction and their clearance measures specific drug metabolizing pathways. Recent Findings We highlight one QLFT, the dual cholate test, and introduce the concept of a disease severity index (DSI) linked to clinical outcome that quantifies the simultaneous processes of hepatocyte uptake, clearance from the systemic circulation, clearance from the portal circulation, and portal-systemic shunting. Summary It is our opinion that dual cholate is a relevant test for defining disease severity, monitoring the natural course of disease progression, and quantifying the response to therapy. PMID:25714706

  13. Percutaneous vesicoamniotic shunting versus conservative management for fetal lower urinary tract obstruction (PLUTO): a randomised trial

    PubMed Central

    Morris, Rachel K; Malin, Gemma L; Quinlan-Jones, Elisabeth; Middleton, Lee J; Hemming, Karla; Burke, Danielle; Daniels, Jane P; Khan, Khalid S; Deeks, Jon; Kilby, Mark D

    2013-01-01

    Summary Background Fetal lower urinary tract obstruction (LUTO) is associated with high perinatal and long-term childhood mortality and morbidity. We aimed to assess the effectiveness of vesicoamniotic shunting for treatment of LUTO. Methods In a randomised trial in the UK, Ireland, and the Netherlands, women whose pregnancies with a male fetus were complicated by isolated LUTO were randomly assigned by a central telephone and web-based randomisation service to receive either the intervention (placement of vesicoamniotic shunt) or conservative management. Allocation could not be masked from clinicians or participants because of the invasive nature of the intervention. Diagnosis was by prenatal ultrasound. The primary outcome was survival of the baby to 28 days postnatally. All primary analyses were done on an intention-to-treat basis, but these results were compared with those of an as-treated analysis to investigate the effect of a fairly large proportion of crossovers. We used Bayesian methods to estimate the posterior probability distribution of the effectiveness of vesicoamniotic shunting at 28 days. The study is registered with the ISRCTN Register, number ISRCTN53328556. Findings 31 women with singleton pregnancies complicated by LUTO were included in the trial and main analysis, with 16 allocated to the vesicoamniotic shunt group and 15 to the conservative management group. The study closed early because of poor recruitment. There were 12 livebirths in each group. In the vesicoamniotic shunt group one intrauterine death occurred and three pregnancies were terminated. In the conservative management group one intrauterine death occurred and two pregnancies were terminated. Of the 16 pregnancies randomly assigned to vesicoamniotic shunting, eight neonates survived to 28 days, compared with four from the 15 pregnancies assigned to conservative management (intention-to-treat relative risk [RR] 1·88, 95% CI 0·71–4·96; p=0·27). Analysis based on treatment received showed a larger effect (3·20, 1·06–9·62; p=0·03). All 12 deaths were caused by pulmonary hypoplasia in the early neonatal period. Sensitivity analysis in which non-treatment-related terminations of pregnancy were excluded made some slight changes to point estimates only. Bayesian analysis in which the trial data were combined with elicited priors from experts suggested an 86% probability that vesicoamniotic shunting increased survival at 28 days and a 25% probability that it had a large, clinically important effect (defined as a relative increase of 55% or more in the proportion of neonates who survived). There was substantial short-term and long-term morbidity in both groups, including poor renal function—only two babies (both in the shunt group) survived to 2 years with normal renal function. Seven complications occurred in six fetuses from the shunt group, including spontaneous ruptured membranes, shunt blockage, and dislodgement. These complications resulted in four pregnancy losses. Interpretation Survival seemed to be higher in the fetuses receiving vesicoamniotic shunting, but the size and direction of the effect remained uncertain, such that benefit could not be conclusively proven. Our results suggest that the chance of newborn babies surviving with normal renal function is very low irrespective of whether or not vesicoamniotic shunting is done. Funding UK National Institute of Health Research, Wellbeing of Women, Hannah Eliza Guy Charity (Birmingham Children's Hospital Charity). PMID:23953766

  14. Intrauterine myelomeningocele repair postnatal results and follow-up at 3.5 years of age--initial experience from a single reference service in Brazil.

    PubMed

    Hisaba, Wagner Jou; Cavalheiro, Sérgio; Almodim, Carlos Gilberto; Borges, Carolina Peixoto; de Faria, Tereza Cristina Carbonari; Araujo Júnior, Edward; Nardozza, Luciano Marcondes Machado; Moron, Antonio Fernandes

    2012-03-01

    Present the outcomes of six cases submitted to intrauterine myelomeningocele (MMC) repair. Descriptive observational study of six children submitted to antenatal surgical repair of MMC between 26 and 27 weeks gestation. All deliveries were through cesarean section. The following neonatal variables were assessed: gestational age at delivery, birth weight, Apgar scores, need for intubation, duration of hospital stay and need for postnatal shunt procedures. After 3.5 years, the children were evaluated using the Columbia Mental Maturity Scale or Denver II tests and the Hoffer Ambulation Scale. All deliveries were preterm at a mean gestational age of 32 + 4 weeks and mean birth weight was 1,942 g. Two infants had Apgar scores <7 at 1 min and 1 at 5 min. Ventricular-peritoneal shunts were placed in two cases. All six children are alive: five have normal cognitive development and one has a neuropsychomotor developmental delay. Two children had normal leg movements, a sacral functional level and are community ambulators. Three children had upper lumbar anatomical level lesions and one had a lower thoracic level lesion at the time of fetal surgery. One child, with an L1-L2 anatomical level lesion, in noambulatory and fully dependent on a wheelchair for mobility. Antenatal surgical repair of MMC reduced the need for postnatal shunt placements. Despite preterm delivery, the cognitive development of most children at 3.5 years was normal. Antenatal surgery seemed to improve lower limb motor function in these cases.

  15. EEG and Neuronal Activity Topography analysis can predict effectiveness of shunt operation in idiopathic normal pressure hydrocephalus patients☆

    PubMed Central

    Aoki, Yasunori; Kazui, Hiroaki; Tanaka, Toshihisa; Ishii, Ryouhei; Wada, Tamiki; Ikeda, Shunichiro; Hata, Masahiro; Canuet, Leonides; Musha, Toshimitsu; Matsuzaki, Haruyasu; Imajo, Kaoru; Yoshiyama, Kenji; Yoshida, Tetsuhiko; Shimizu, Yoshiro; Nomura, Keiko; Iwase, Masao; Takeda, Masatoshi

    2013-01-01

    Idiopathic normal pressure hydrocephalus (iNPH) is a neuropsychiatric syndrome characterized by gait disturbance, cognitive impairment and urinary incontinence that affect elderly individuals. These symptoms can potentially be reversed by cerebrospinal fluid (CSF) drainage or shunt operation. Prior to shunt operation, drainage of a small amount of CSF or “CSF tapping” is usually performed to ascertain the effect of the operation. Unfortunately, conventional neuroimaging methods such as single photon emission computed tomography (SPECT) and functional magnetic resonance imaging (fMRI), as well as electroencephalogram (EEG) power analysis seem to have failed to detect the effect of CSF tapping on brain function. In this work, we propose the use of Neuronal Activity Topography (NAT) analysis, which calculates normalized power variance (NPV) of EEG waves, to detect cortical functional changes induced by CSF tapping in iNPH. Based on clinical improvement by CSF tapping and shunt operation, we classified 24 iNPH patients into responders (N = 11) and nonresponders (N = 13), and performed both EEG power analysis and NAT analysis. We also assessed correlations between changes in NPV and changes in functional scores on gait and cognition scales before and after CSF tapping. NAT analysis showed that after CSF tapping there was a significant decrease in alpha NPV at the medial frontal cortex (FC) (Fz) in responders, while nonresponders exhibited an increase in alpha NPV at the right dorsolateral prefrontal cortex (DLPFC) (F8). Furthermore, we found correlations between cortical functional changes and clinical symptoms. In particular, delta and alpha NPV changes in the left-dorsal FC (F3) correlated with changes in gait status, while alpha and beta NPV changes in the right anterior prefrontal cortex (PFC) (Fp2) and left DLPFC (F7) as well as alpha NPV changes in the medial FC (Fz) correlated with changes in gait velocity. In addition, alpha NPV changes in the right DLPFC (F8) correlated with changes in WMS-R Mental Control scores in iNPH patients. An additional analysis combining the changes in values of alpha NPV over the left-dorsal FC (∆alpha-F3-NPV) and the medial FC (∆alpha-Fz-NPV) induced by CSF tapping (cut-off value of ∆alpha-F3-NPV + ∆alpha-Fz-NPV = 0), could correctly identified “shunt responders” and “shunt nonresponders” with a positive predictive value of 100% (10/10) and a negative predictive value of 66% (2/3). In contrast, EEG power spectral analysis showed no function related changes in cortical activity at the frontal cortex before and after CSF tapping. These results indicate that the clinical changes in gait and response suppression induced by CSF tapping in iNPH patients manifest as NPV changes, particularly in the alpha band, rather than as EEG power changes. Our findings suggest that NAT analysis can detect CSF tapping-induced functional changes in cortical activity, in a way that no other neuroimaging methods have been able to do so far, and can predict clinical response to shunt operation in patients with iNPH. PMID:24273735

  16. EEG and Neuronal Activity Topography analysis can predict effectiveness of shunt operation in idiopathic normal pressure hydrocephalus patients.

    PubMed

    Aoki, Yasunori; Kazui, Hiroaki; Tanaka, Toshihisa; Ishii, Ryouhei; Wada, Tamiki; Ikeda, Shunichiro; Hata, Masahiro; Canuet, Leonides; Musha, Toshimitsu; Matsuzaki, Haruyasu; Imajo, Kaoru; Yoshiyama, Kenji; Yoshida, Tetsuhiko; Shimizu, Yoshiro; Nomura, Keiko; Iwase, Masao; Takeda, Masatoshi

    2013-01-01

    Idiopathic normal pressure hydrocephalus (iNPH) is a neuropsychiatric syndrome characterized by gait disturbance, cognitive impairment and urinary incontinence that affect elderly individuals. These symptoms can potentially be reversed by cerebrospinal fluid (CSF) drainage or shunt operation. Prior to shunt operation, drainage of a small amount of CSF or "CSF tapping" is usually performed to ascertain the effect of the operation. Unfortunately, conventional neuroimaging methods such as single photon emission computed tomography (SPECT) and functional magnetic resonance imaging (fMRI), as well as electroencephalogram (EEG) power analysis seem to have failed to detect the effect of CSF tapping on brain function. In this work, we propose the use of Neuronal Activity Topography (NAT) analysis, which calculates normalized power variance (NPV) of EEG waves, to detect cortical functional changes induced by CSF tapping in iNPH. Based on clinical improvement by CSF tapping and shunt operation, we classified 24 iNPH patients into responders (N = 11) and nonresponders (N = 13), and performed both EEG power analysis and NAT analysis. We also assessed correlations between changes in NPV and changes in functional scores on gait and cognition scales before and after CSF tapping. NAT analysis showed that after CSF tapping there was a significant decrease in alpha NPV at the medial frontal cortex (FC) (Fz) in responders, while nonresponders exhibited an increase in alpha NPV at the right dorsolateral prefrontal cortex (DLPFC) (F8). Furthermore, we found correlations between cortical functional changes and clinical symptoms. In particular, delta and alpha NPV changes in the left-dorsal FC (F3) correlated with changes in gait status, while alpha and beta NPV changes in the right anterior prefrontal cortex (PFC) (Fp2) and left DLPFC (F7) as well as alpha NPV changes in the medial FC (Fz) correlated with changes in gait velocity. In addition, alpha NPV changes in the right DLPFC (F8) correlated with changes in WMS-R Mental Control scores in iNPH patients. An additional analysis combining the changes in values of alpha NPV over the left-dorsal FC (∆alpha-F3-NPV) and the medial FC (∆alpha-Fz-NPV) induced by CSF tapping (cut-off value of ∆alpha-F3-NPV + ∆alpha-Fz-NPV = 0), could correctly identified "shunt responders" and "shunt nonresponders" with a positive predictive value of 100% (10/10) and a negative predictive value of 66% (2/3). In contrast, EEG power spectral analysis showed no function related changes in cortical activity at the frontal cortex before and after CSF tapping. These results indicate that the clinical changes in gait and response suppression induced by CSF tapping in iNPH patients manifest as NPV changes, particularly in the alpha band, rather than as EEG power changes. Our findings suggest that NAT analysis can detect CSF tapping-induced functional changes in cortical activity, in a way that no other neuroimaging methods have been able to do so far, and can predict clinical response to shunt operation in patients with iNPH.

  17. Chronic ("normal pressure") hydrocephalus in childhood and adolescence. A review of 16 cases and reappraisal of the syndrome.

    PubMed

    Bret, P; Chazal, J

    1995-12-01

    "Normal pressure" hydrocephalus (NPH) is generally considered to be a disorder of the adult and geriatric population. Only a few reports have described the possible occurrence of this condition in children. A series of 16 patients aged less than 20 years forms the basis of the present report. Among these 16 patients, 11 had a clearly identified etiologic factor and 7 had had a shunt previously implanted. The majority of patients exhibited at least two elements of the adult's triad of psychomotor retardation (14 cases) and/or psychotic-like symptoms (4 cases), gait anomalies (8 cases), and sphincter disturbances (3 cases). Six patients had their intracranial pressure (ICP) monitored. ICP values were estimated to be within the normal limits for age. All the 16 patients underwent shunting or shunt revision. Surgical results were as follows (mean follow-up 20 +/- 17.2 months): a good response to shunting was obtained in 12 cases ("cured": 5, improved: 7), while the other 4 patients failed to improve. It seems likely that associated parenchymal disorders have played a major role in therapeutic failures. In children showing ventricular dilation on computed tomographic (CT) analysis and a clinical picture of subtle psychomotor deterioration, it may be difficult to distinguish an active disorder of the CSF dynamics from "arrested hydrocephalus." Since intracranial manometry cannot be undertaken as a routine procedure, less invasive methods such as cerebrospinal fluid (CSF) tap test, psychometric, or urodynamic tests deserve special attention as reliable predictors of outcome after shunting. Because most patients undergo shunting without prior assessment of their CSF pressure, the term "chronic hydrocephalus" is proposed as an alternative designation to "NPH," since there is little argument for maintaining an instrumentally based definition of the syndrome.

  18. Comparison between the lumbar infusion and CSF tap tests to predict outcome after shunt surgery in suspected normal pressure hydrocephalus

    PubMed Central

    Kahlon, B; Sundbarg, G; Rehncrona, S

    2002-01-01

    Objective: To compare the lumbar infusion test and the cerebrospinal fluid (CSF) tap test for predicting the outcome of shunt surgery in patients with suspected normal pressure hydrocephalus. Methods: 68 patients with suspected normal pressure hydrocephalus were studied. The absence of preceding history indicated idiopathic disease in 75% of these. All patients were assessed twice with walking and psychometric tests before lumbar infusion test and tap test assessments. The lumbar infusion test was done using a constant infusion rate (0.80 ml/min) and regarded as positive if the steady state CSF plateau pressure reached levels of > 22 mm Hg (resistance to outflow > 14 mm Hg/ml/min). The tap test was regarded as positive if two or more of four different test items improved after CSF removal. As the variability in baseline test results was large, the better of two evaluations was used in comparisons with the results after CSF removal, as well as to evaluate the outcome after shunt surgery. Only patients with a positive lumbar infusion test or a positive tap test had surgery. Results: The results of the CSF tap test and the lumbar infusion test agreed in only 45% of the patients. Of the total cohort, 47 (69%) had positive test results and were operated on; 45 (96%) of these reported subjective improvement, and postoperative assessments verified the improvements in 38 (81%). Improvements were highly significant in walking, memory, and reaction time tests (p < 0.001). Most of the patients improved by surgery (84%) were selected by a positive lumbar infusion test, and only 42% by a positive tap test. Positive predictive values were 80% for lumbar infusion test and 94% for tap test. The false negative predictions in the operated group were much higher (58%) with the tap test than with the lumbar infusion test (16%). Conclusions: Both the lumbar infusion test and the tap test can predict a positive outcome of shunt operations in unselected patients with suspected normal pressure hydrocephalus. The two tests are complementary and should be used together for optimal patient selection. PMID:12438477

  19. Comparison between the lumbar infusion and CSF tap tests to predict outcome after shunt surgery in suspected normal pressure hydrocephalus.

    PubMed

    Kahlon, B; Sundbärg, G; Rehncrona, S

    2002-12-01

    To compare the lumbar infusion test and the cerebrospinal fluid (CSF) tap test for predicting the outcome of shunt surgery in patients with suspected normal pressure hydrocephalus. 68 patients with suspected normal pressure hydrocephalus were studied. The absence of preceding history indicated idiopathic disease in 75% of these. All patients were assessed twice with walking and psychometric tests before lumbar infusion test and tap test assessments. The lumbar infusion test was done using a constant infusion rate (0.80 ml/min) and regarded as positive if the steady state CSF plateau pressure reached levels of > 22 mm Hg (resistance to outflow > 14 mm Hg/ml/min). The tap test was regarded as positive if two or more of four different test items improved after CSF removal. As the variability in baseline test results was large, the better of two evaluations was used in comparisons with the results after CSF removal, as well as to evaluate the outcome after shunt surgery. Only patients with a positive lumbar infusion test or a positive tap test had surgery. The results of the CSF tap test and the lumbar infusion test agreed in only 45% of the patients. Of the total cohort, 47 (69%) had positive test results and were operated on; 45 (96%) of these reported subjective improvement, and postoperative assessments verified the improvements in 38 (81%). Improvements were highly significant in walking, memory, and reaction time tests (p < 0.001). Most of the patients improved by surgery (84%) were selected by a positive lumbar infusion test, and only 42% by a positive tap test. Positive predictive values were 80% for lumbar infusion test and 94% for tap test. The false negative predictions in the operated group were much higher (58%) with the tap test than with the lumbar infusion test (16%). Both the lumbar infusion test and the tap test can predict a positive outcome of shunt operations in unselected patients with suspected normal pressure hydrocephalus. The two tests are complementary and should be used together for optimal patient selection.

  20. Simulation model for port shunting yards

    NASA Astrophysics Data System (ADS)

    Rusca, A.; Popa, M.; Rosca, E.; Rosca, M.; Dragu, V.; Rusca, F.

    2016-08-01

    Sea ports are important nodes in the supply chain, joining two high capacity transport modes: rail and maritime transport. The huge cargo flows transiting port requires high capacity construction and installation such as berths, large capacity cranes, respectively shunting yards. However, the port shunting yards specificity raises several problems such as: limited access since these are terminus stations for rail network, the in-output of large transit flows of cargo relatively to the scarcity of the departure/arrival of a ship, as well as limited land availability for implementing solutions to serve these flows. It is necessary to identify technological solutions that lead to an answer to these problems. The paper proposed a simulation model developed with ARENA computer simulation software suitable for shunting yards which serve sea ports with access to the rail network. Are investigates the principal aspects of shunting yards and adequate measures to increase their transit capacity. The operation capacity for shunting yards sub-system is assessed taking in consideration the required operating standards and the measure of performance (e.g. waiting time for freight wagons, number of railway line in station, storage area, etc.) of the railway station are computed. The conclusion and results, drawn from simulation, help transports and logistics specialists to test the proposals for improving the port management.

  1. The effects on increasing cardiac output with adrenaline or isoprenaline on arterial haemoglobin oxygen saturation and shunt during one-lung ventilation.

    PubMed

    Russell, W J; James, M F

    2000-12-01

    Theoretically, if the cardiac output were increased in the presence of a given intrapulmonary shunt, the arterial haemoglobin oxygen saturation (SaO2) should improve as the venous oxygen extraction per ml of blood decreases. To test this hypothesis, eight pigs were subjected to one-lung ventilation and adrenaline and isoprenaline infusions used to increase the cardiac output. The mixed venous oxygen, shunt fraction and oxygen consumption were measured. With both adrenaline and isoprenaline, although there was a small rise in mixed venous oxygen content, there was a fall in SaO2. With adrenaline, the mean shunt rose from 48% to 65%, the mean oxygen consumption rose from 126 ml/min to 134 ml/min and the mean SaO2 fell from 86.9% to 82.5%. With isoprenaline, the mean shunt rose from 45% to 59%, the mean oxygen consumption rose from 121 ml/min to 137 ml/min and the mean SaO2 fell from 89.5% to 84.7%. It is concluded that potential improvement in SaO2, which might occur from a catecholamine-induced increase in mixed venous oxygen content during one-lung ventilation, is more than offset by increased shunting and oxygen consumption which reduce SaO2.

  2. Manipulating waves by distilling frequencies: a tunable shunt-enabled rainbow trap

    NASA Astrophysics Data System (ADS)

    Cardella, Davide; Celli, Paolo; Gonella, Stefano

    2016-08-01

    In this work, we propose and test a strategy for tunable, broadband wave attenuation in electromechanical waveguides with shunted piezoelectric inclusions. Our strategy is built upon the vast pre-existing literature on vibration attenuation and bandgap generation in structures featuring periodic arrays of piezo patches, but distinguishes itself for several key features. First, we demystify the idea that periodicity is a requirement for wave attenuation and bandgap formation. We further embrace the idea of ‘organized disorder’ by tuning the circuits as to resonate at distinct neighboring frequencies. In doing so, we create a tunable ‘rainbow trap’ (Tsakmakidis et al 2007 Nature 450 397-401) capable of attenuating waves with broadband characteristics, by distilling (sequentially) seven frequencies from a traveling wavepacket. Finally, we devote considerable attention to the implications in terms of packet distortion of the spectral manipulation introduced by shunting. This work is also meant to serve as a didactic tool for those approaching the field of shunted piezoelectrics, and attempts to provide a different perspective, with abundant details, on how to successfully design an experimental setup involving resistive-inductive shunts.

  3. Management of idiopathic intracranial hypertension with a programmable lumboperitoneal shunt: Early experience.

    PubMed

    Alkherayf, Fahad; Abou Al-Shaar, Hussam; Awad, Michael

    2015-09-01

    To evaluate the clinical outcomes and complications rate among idiopathic intracranial hypertension (IIH) patients who underwent lumboperitoneal (LP) shunt insertion with a programmable Strata valve. We retrospectively evaluated patients who underwent LP shunt with a programmable Strata valve insertion at the University of Ottawa Civic Hospital from November 2012 to June 2013. The demographic data, clinical symptoms, opening pressure, pre-operative and post-operative visual fields, neuroimaging, visual acuity, disc status, and complications were recorded and analyzed. Seven female patients with IIH underwent insertion of an LP shunt with a programmable Strata valve. The mean opening pressure was 35.8 cm H2O. The initial valve setting was 1.5, and four patients required post-operative valve pressure adjustment. All patients showed significant improvement in objective visual testing at follow-up as well as less frequent headaches. None of the patients developed intra- or post-operative complications. LP shunts with programmable Strata valve systems are a potential alternative to conventional LP and programmable ventriculoperitoneal shunt systems as well as optic nerve sheath fenestration, due to their potential in avoiding brain injury, lower failure and complication rates, lower intracranial hypotension incidence, and flexibility in adjusting valve pressure settings post-operatively evading under- and overdrainage complications. They should be considered for the management of IIH instead of early design LP systems and VP shunts. A randomized multi-center trial should be conducted to compare the efficacy of these surgical techniques. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. A randomised trial of high and low pressure level settings on an adjustable ventriculoperitoneal shunt valve for idiopathic normal pressure hydrocephalus: results of the Dutch evaluation programme Strata shunt (DEPSS) trial.

    PubMed

    Delwel, Ernst J; de Jong, Dirk A; Dammers, Ruben; Kurt, Erkan; van den Brink, Wimar; Dirven, Clemens M F

    2013-07-01

    In treating idiopathic normal pressure hydrocephalus (INPH) with a shunt there is always a risk of underdrainage or overdrainage. The hypothesis is tested whether patients treated using an adjustable valve preset at the highest opening pressure leads to comparable good clinical results with less subdural effusions than in a control group with an opening pressure preset at a low pressure level. A multicentre prospective randomised trial was performed on a total of 58 patients suspected of INPH. Thirty patients were assigned to (control) group 1 and received a Strata shunt (Medtronic, Goleta, USA) with the valve preset at a performance level (PL) of 1.0, while 28 patients were assigned to group 2 and received a Strata shunt with the valve preset at PL 2.5. In this group the PL was allowed to be lowered until improvement or radiological signs of overdrainage were met. Significantly more subdural effusions were observed in the improved patients of group 1. There was no statistically significant difference in improvement between both groups overall. On the basis of this multicentre prospective randomised trial it is to be recommended to treat patients with INPH with a shunt with an adjustable valve, preset at the highest opening pressure and lowered until clinical improvement or radiological signs of overdrainage occur although slower improvement and more shunt adjustments might be the consequence.

  5. Organ distribution of 13N following intravenous injection of [13N]ammonia into portacaval-shunted rats

    PubMed Central

    Cruz, Nancy F.; Dienel, Gerald A.; Patrick, Tricia A.; Cooper, Arthur J. L.

    2016-01-01

    Ammonia is neurotoxic, and chronic hyperammonemia is thought to be a major contributing factor to hepatic encephalopathy in patients with liver disease. Portacaval shunting of rats is used as an animal model to study the detrimental metabolic effects of elevated ammonia levels on body tissues, particularly brain and testes that are deleteriously targeted by high blood ammonia. In normal adult rats, the initial uptake of label (expressed as relative concentration) in these organs was relatively low following a bolus intravenous injection of [13N]ammonia compared with lungs, kidneys, liver, and some other organs. The objective of the present study was to determine the distribution of label following intravenous administration of [13N]ammonia among 14 organs in portacaval-shunted rats at 12 weeks after shunt construction. At an early time point (12 sec) following administration of [13N]ammonia the relative concentration of label was highest in lung with lower, but still appreciable relative concentrations in kidney and heart. Clearance of 13N from blood and kidney tended to be slower in portacaval-shunted rats versus normal rats during the 2–10 min interval after the injection. At later times post injection, brain and testes tended to have higher-than-normal 13N levels, whereas many other tissues had similar levels in both groups. Thus, reduced removal of ammonia from circulating blood by the liver diverts more ammonia to extrahepatic tissues, including brain and testes, and alters the nitrogen homeostasis in these tissues. These results emphasize the importance of treatment paradigms designed to reduce blood ammonia levels in patients with liver disease. PMID:27822667

  6. Organ Distribution of 13N Following Intravenous Injection of [13N]Ammonia into Portacaval-Shunted Rats.

    PubMed

    Cruz, Nancy F; Dienel, Gerald A; Patrick, Patricia A; Cooper, Arthur J L

    2017-06-01

    Ammonia is neurotoxic, and chronic hyperammonemia is thought to be a major contributing factor to hepatic encephalopathy in patients with liver disease. Portacaval shunting of rats is used as an animal model to study the detrimental metabolic effects of elevated ammonia levels on body tissues, particularly brain and testes that are deleteriously targeted by high blood ammonia. In normal adult rats, the initial uptake of label (expressed as relative concentration) in these organs was relatively low following a bolus intravenous injection of [ 13 N]ammonia compared with lungs, kidneys, liver, and some other organs. The objective of the present study was to determine the distribution of label following intravenous administration of [ 13 N]ammonia among 14 organs in portacaval-shunted rats at 12 weeks after shunt construction. At an early time point (12 s) following administration of [ 13 N]ammonia the relative concentration of label was highest in lung with lower, but still appreciable relative concentrations in kidney and heart. Clearance of 13 N from blood and kidney tended to be slower in portacaval-shunted rats versus normal rats during the 2-10 min interval after the injection. At later times post injection, brain and testes tended to have higher-than-normal 13 N levels, whereas many other tissues had similar levels in both groups. Thus, reduced removal of ammonia from circulating blood by the liver diverts more ammonia to extrahepatic tissues, including brain and testes, and alters the nitrogen homeostasis in these tissues. These results emphasize the importance of treatment paradigms designed to reduce blood ammonia levels in patients with liver disease.

  7. Compensatory parameters of intracranial space in giant hydrocephalus.

    PubMed

    Cieślicki, Krzysztof; Czepko, Ryszard

    2009-01-01

    The main goal of the present study is to examine compensatory parameters of intracranial space in giant hydrocephalus. We also assess the early and late outcome and analyse complications in shunted cases. Nine cases of giant hydrocephalus characterised by the value of Evans ratio > 0.5, ventricular index > 1.5, and the width of the third ventricle > 20 mm were considered. Using the lumbar infusion test and developed software we analysed the intracranial compensatory parameters typical for hydrocephalus. Based on the Marmarou model, the method depended on a repeated search for the best fitting curve corresponding to the progress of the test was used. Eight out of nine patients were therefore shunted. Patients were followed up for 9 months. Five out of eight shunted patients undoubtedly improved in a few days after surgery (62%). Complications (subdural hygromas/haematomas and intracerebral haematoma) developed in 5 (62%) cases in longer follow-up. A definite improvement was noted in 4 out of 8 operated cases (50%). To get the stable values of compensatory parameters, the duration of the infusion test must at least double the inflexion time of the test curve. All but one considered cases of giant hydrocephalus were characterized by lack of intracranial space reserve, significantly reduced rate of CSF secretion and by various degrees of elevated value of the resistance to outflow. Due to the significant number of complications and uncertain long-term improvement, great caution in decision making for shunting has to be taken.

  8. What radiologists need to know about the pulmonary-systemic flow ratio (Qp/Qs): what it is, how to calculate it, and what it is for.

    PubMed

    Marín Rodríguez, C; Sánchez Alegre, M L; Lancharro Zapata, Á; Alarcón Rodríguez, J

    2015-01-01

    Cardiac magnetic resonance imaging (cMRI) provides abundant morphological and functional information in the study of congenital heart disease. The functional information includes pulmonary output and systemic output; the ratio between these two (Qp/Qs) is the shunt fraction. After birth, in normal conditions the pulmonary output is practically identical to the systemic output, so Qp/Qs = 1. In patients with « shunts » between the systemic and pulmonary circulations, the ratio changes, and the interpretation of these findings varies in function of the location of the shunt (intracardiac or extracardiac) and of the associated structural or postsurgical changes. We review the concept of Qp/Qs; the methods to calculate it, with special emphasis on cMRI; and the meaning of the results obtained. We place special emphasis on the relevance of these findings depending on the underlying disease and the treatment the patient has undergone. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  9. Practice guideline: Idiopathic normal pressure hydrocephalus: Response to shunting and predictors of response: Report of the Guideline Development, Dissemination, and Implementation Subcommittee of the American Academy of Neurology.

    PubMed

    Halperin, John J; Kurlan, Roger; Schwalb, Jason M; Cusimano, Michael D; Gronseth, Gary; Gloss, David

    2015-12-08

    We evaluated evidence for utility of shunting in idiopathic normal pressure hydrocephalus (iNPH) and for predictors of shunting effectiveness. We identified and classified relevant published studies according to 2004 and 2011 American Academy of Neurology methodology. Of 21 articles, we identified 3 Class I articles. Shunting is possibly effective in iNPH (96% chance subjective improvement, 83% chance improvement on timed walk test at 6 months) (3 Class III). Serious adverse event risk was 11% (1 Class III). Predictors of success included elevated Ro (1 Class I, multiple Class II), impaired cerebral blood flow reactivity to acetazolamide (by SPECT) (1 Class I), and positive response to either external lumbar drainage (1 Class III) or repeated lumbar punctures. Age may not be a prognostic factor (1 Class II). Data are insufficient to judge efficacy of radionuclide cisternography or aqueductal flow measurement by MRI. Clinicians may choose to offer shunting for subjective iNPH symptoms and gait (Level C). Because of significant adverse event risk, risks and benefits should be carefully weighed (Level B). Clinicians should inform patients with iNPH with elevated Ro and their families that they have an increased chance of responding to shunting compared with those without such elevation (Level B). Clinicians may counsel patients with iNPH and their families that (1) positive response to external lumbar drainage or to repeated lumbar punctures increases the chance of response to shunting, and (2) increasing age does not decrease the chance of shunting being successful (both Level C). © 2015 American Academy of Neurology.

  10. [Results of the mesoportal bypass (Rex shunt) in the treatment of idiopathic extrahepatic portal vein obstruction in children].

    PubMed

    Domínguez Amillo, E; De la Torre Ramos, C; Andrés Moreno, A; Encinas Hernández, J L; Hernández Oliveros, F; López Santamaría, M

    2017-01-25

    Extrahepatic portal vein obstruction (EPVO) is the principal cause of portal hypertension in children. The objective of this study was to analyze the capacity of the surgical technique that creates a mesoportal shunt to treat changes caused by EPVO. Retrospective review of patients with idiopathic EPVO who underwent a mesoportal shunt and analysis of the changes in the number of leucocytes, platelets, prothrombin time and spleen size one year after the surgery. Twelve patients underwent surgery, out of which 10 had prior leukopenia, 11 thrombopenia, 9 longer prothrombin times and all had hypersplenism. One patient suffered a postoperative shunt thrombosis, was reoperated and underwent a change in the operative technique. The remaining patients (92%) have functioning shunts 4.3 ± 2.5 years after surgery, and none have suffered any episode of gastrointestinal bleeding. One year after surgery, there were significant changes in the number of platelets, prothrombin time and spleen size, with no significant changes in the number of leukocytes. However, the number of patients who went from a leukopenic to a normal state was significant, as happened with changes in prothrombin time. Mesoportal Rex shunt improves some of the disorders caused by portal hypertension in children suffering EPVO, with a high rate of surgical success. This technique should be of first choice in these patients.

  11. Long-term results of small-diameter proximal splenorenal venous shunt: A retrospective study

    PubMed Central

    Chen, Hao; Yang, Wei-Ping; Yan, Ji-Qi; Li, Qin-Yu; Ma, Di; Li, Hong-Wei

    2011-01-01

    AIM: To investigate recurrent variceal hemorrhage and long-term survival rates of patients treated with partial proximal splenorenal venous shunt. METHODS: Patients with variceal hemorrhage who were treated with small-diameter proximal splenorenal venous shunt in Ruijin Hospital between 1996 and 2009 were included in this study. Shunt diameter was determined before operation using Duplex Doppler ultrasonography. Peri-operative and long-term results in term of rehemorrhage, encephalopathy and mortality were followed up. RESULTS: Ninety-eight patients with Child A and B variceal hemorrhage received small-diameter proximal splenorenal venous shunt with a diameter of 7-10 mm. After operation, the patients’ mean free portal pressure (P < 0.01) and the flow rate of main portal vein (P < 0.01) decreased significantly compared with that before operation. The rates of rebleeding and mortality were 6.12% (6 cases) and 2.04% (2 cases), respectively. Ninety-one patients were followed up for 7 mo-14 years (median, 48.57 mo). Long-term rates of rehemorrhage and encephalopathy were 4.40% (4 cases) and 3.30% (3 cases), respectively. Thirteen patients (14.29%) died mainly due to progressive hepatic dysfunction. Five- and ten-year survival rates were 82.12% and 71.24%, respectively. CONCLUSION: Small-diameter proximal splenorenal venous shunt affords protection against variceal rehemorrhage with a low occurrence of encephalopathy in patients with normal liver function. PMID:21876638

  12. Ventriculoarterial coupling in palliated hypoplastic left heart syndrome: Noninvasive assessment of the effects of surgical arch reconstruction and shunt type.

    PubMed

    Biglino, Giovanni; Giardini, Alessandro; Ntsinjana, Hopewell N; Schievano, Silvia; Hsia, Tain-Yen; Taylor, Andrew M

    2014-10-01

    To assess the coupling efficiency in hypoplastic left heart syndrome, considering the effect of surgical arch reconstruction and the shunt type received during the Norwood procedure. Ventriculoarterial coupling was assessed before Fontan completion in 32 patients with hypoplastic left heart syndrome (19 modified Blalock-Taussig and 13 Sano shunts at stage 1). Cardiovascular magnetic resonance data were analyzed, deriving functional parameters and 3-dimensional volumes. Dimensional indexes were computed from 3-dimensional data sets as the area ratio of the isthmus to the descending aorta (Risthmus) and the isthmus to surgically enlarged transverse arch (Rarch). Wave intensity was calculated from cardiac magnetic resonance, using the peaks of the forward compression and expansion waves in early and late systole as surrogate indicators of ventriculoarterial coupling. Aortic distensibility (3.6±2.7×10(-3) 1/mm Hg) was not associated with the time elapsed from stage 1 palliation (P=.94), suggesting an early loss of elasticity that did not progress thereafter. Risthmus was 1.0±0.4, and Rarch was 0.3±0.1, indicating the dilated reconstructed arch was the main anatomic feature. The forward compression wave correlated significantly with Rarch (R2=0.23, P=.006) but not with Risthmus (R2<0.01, P=.63). Patients with a reduced ejection fraction exhibited a larger ventricular mass (R2=0.28, P=.003). The Sano shunt patients had a lower ejection fraction (51%±6% vs 57%±6%, P=.02); however, neither the forward compression nor expansion wave varied significantly between shunt type or the other functional parameters. Ventriculoarterial coupling in operated hypoplastic left heart syndrome was affected by aortic arch size mismatch but not by the type of shunt placed at the Norwood operation. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  13. A 27-Year Experience With Surgical Treatment of Budd-Chiari Syndrome

    PubMed Central

    Orloff, Marshall J.; Daily, Pat O.; Orloff, Susan L.; Girard, Barbara; Orloff, Mark S.

    2000-01-01

    Objective To determine the effects of surgical portal decompression in Budd-Chiari syndrome (BCS) on survival, quality of life, shunt patency, liver function, portal hemodynamics, and hepatic morphology during periods ranging from 3.5 to 27 years. Summary Background Data Experiments in the authors’ laboratory showed that surgical portal decompression reversed the deleterious effects of BCS on the liver. This study was aimed at determining whether similar benefit could be obtained in patients with BCS. Methods From 1972 to 1999, the authors conducted prospective studies of the treatment of 60 patients with BCS who were divided into three groups: the first had occlusion confined to the hepatic veins treated by direct side-to-side portacaval shunt (SSPCS); the second had occlusion involving the inferior vena cava (IVC) treated by a portal decompressive procedure that bypassed the obstructed IVC; and the third group, who had advanced cirrhosis and hepatic decompensation and were referred too late for treatment by portal decompression, required orthotopic liver transplantation. Results In the 32 patients with BCS resulting from hepatic vein occlusion alone, SSPCS had a surgical death rate of 3%, and 94% of the patients were alive 3.5 to 27 years after surgery. All 31 survivors remained free of ascites and almost all had normal liver function. No patient with a patent shunt had encephalopathy. The SSPCS remained patent in all but one patient. Liver biopsies showed no evidence of congestion or necrosis, and 48% of the biopsies were diagnosed as normal. Mesoatrial shunt was performed in eight patients with BCS caused by IVC thrombosis. All patients survived surgery, but five subsequently developed thrombosis of the synthetic graft and died. Because of the poor results, mesoatrial shunt was abandoned. Instead, a high-flow combination shunt was introduced, consisting of SSPCS combined with a cavoatrial shunt (CAS) through a Gore-Tex graft. There were no surgical or long-term deaths among 10 patients who underwent combined SSPCS and CAS, and the shunts functioned effectively during 4 to 16 years of follow-up. Ten patients with advanced cirrhosis were referred too late to benefit from surgical portal decompression, and they were approved and listed for orthotopic liver transplantation. Three patients died of liver failure while awaiting a transplant, and four patients died after the transplant. The 1- and 5-year survival rates were 40% and 30%, respectively. Conclusions SSPCS in BCS with hepatic vein occlusion alone results in reversal of liver damage, correction of hemodynamic disturbances, prolonged survival, and good quality of life when performed early in the course of BCS. Similarly good results are obtained with combined SSPCS and CAS in patients with BCS resulting from IVC occlusion. In contrast, mesoatrial shunt has been discontinued in the authors’ program because of an unacceptable incidence of graft thrombosis and death. In patients with advanced cirrhosis from long-standing, untreated BCS, orthotopic liver transplantation is the only hope of relief and results in the salvage of some patients. The key to long survival in BCS is prompt diagnosis and treatment by portal decompression. PMID:10973384

  14. Effect of transjugular intrahepatic portosystemic shunt on pulmonary gas exchange in patients with portal hypertension and hepatopulmonary syndrome

    PubMed Central

    Martínez-Pallí, Graciela; Drake, Britt B; García-Pagán, Joan-Carles; Barberà, Joan-Albert; Arguedas, Miguel R; Rodriguez-Roisin, Robert; Bosch, Jaume; Fallon, Michael B

    2005-01-01

    AIM: To assess the impact of transjugular intrahepatic portosystemic shunt (TIPS) on pulmonary gas exchange and to evaluate the use of TIPS for the treatment of hepatopulmonary syndrome ( HPS ). METHODS: Seven patients, three of them with advanced HPS, in whom detailed pulmonary function tests were performed before and after TIPS placement at the University of Alabama Hospital and at the Hospital Clinic, Barcelona, were considered. RESULTS: TIPS patency was confirmed by hemodynamic evaluation. No changes in arterial blood gases were observed in the overall subset of patients. Transient arterial oxygenation improvement was observed in only one HPS patient, early after TIPS, but this was not sustained 4 mo later. CONCLUSION: TIPS neither improved nor worsened pulmonary gas exchange in patients with portal hypertension. This data does not support the use of TIPS as a specific treatment for HPS. However, it does reinforce the view that TIPS can be safely performed for the treatment of other complications of portal hypertension in patients with HPS. PMID:16425397

  15. Circadian rhythm in idiopathic normal pressure hydrocephalus.

    PubMed

    Eleftheriou, Andreas; Ulander, Martin; Lundin, Fredrik

    2018-01-01

    The pathogenesis of idiopathic normal pressure hydrocephalus (iNPH) takes place in structures close to the cerebral ventricular system. Suprachiasmatic nucleus (SCN), situated close to the third ventricle, is involved in circadian rhythm. Diurnal disturbances are well-known in demented patients. The cognitive decline in iNPH is potentially reversible after a shunt operation. Diurnal rhythm has never been studied in iNPH. We hypothesize that there is a disturbance of circadian rhythm in iNPH-patients and the aim was to study any changes of the diurnal rhythm (mesor and circadian period) as well as any changes of the diurnal amplitude and acrophase of the activity in iNPH-patients before and after a shunt operation. Twenty consecutive iNPH-patients fulfilling the criteria of the American iNPH-guidelines, 9 males and 11 females, mean age 73 (49-81) years were included. The patients underwent a pre-operative clinical work-up including 10m walk time (w10mt) steps (w10ms), TUG-time (TUGt) and steps (TUGs) and for cognitive function an MMSE score was measured. In order to receive circadian rhythm data actigraphic recordings were performed using the SenseWear 2 (BodyMedia Inc Pittsburgh, PA, USA) actigraph. Cosinor analyses of accelerometry data were performed in "R" using non-linear regression with Levenburg- Marquardt estimation. Pre- and post-operative data regarding mesor, amplitude and circadian period were compared using Wilcoxon-Mann-Whitney test for paired data. Twenty patients were evaluated before and three month post-operatively. Motor function (w10mt, w10ms, TUGt, TUGs) was significantly improved while MMSE was not significantly changed. Actigraphic measurements (mesor, amplitude and circadian period) showed no significant changes after shunt operation. This is the first systematic study of circadian rhythm in iNPH-patients. We found no significant changes in circadian rhythm after shunt surgery. The conceptual idea of diurnal rhythm changes in hydrocephalus is still interesting from a theoretical standpoint and warrants further studies that could include a combination of better designed actigraphic studies in combination with neuroendocrine markers and imaging methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Congenital Portosystemic Shunts: Clinic Heterogeneity Requires an Individual Management of the Patient.

    PubMed

    Chocarro, Gloria; Amesty, María Virginia; Encinas, Jose Luis; Vilanova Sánchez, Alejandra; Hernandez, Francisco; Andres, Ane M; Gamez, Manolo; Tovar, Juan Antonio; Lopez Santamaria, Manuel

    2016-02-01

    Congenital portosystemic shunt (CPSS) is a rare entity without insufficiency in treatment issues. The aim of this article is to show our experience in the heterogeneity of this condition. A retrospective study of 25 CPSS in the period 1995 to 2014 was conducted. Description of the morphology, clinical impact, and treatment is given. According to the imaging techniques (IT), the shunt was apparently intrahepatic in 14 patients, extrahepatic in 10 patients, and mixed in 1 patient. In 14 children, IT showed hepatic portal circulation. In total shunts in which radiological examination was performed, invasive radiological techniques were able to demonstrate intrahepatic portal vein. In other patients, it was not investigated as they are asymptomatic. A child presented multiorgan failure with fulminant hepatic failure at birth. The shunt was radiologically closed and clinical impairment reversed rapidly. He is now asymptomatic with no longer images of CPSS in ultrasound scan controls. Also, seven children are asymptomatic at this time and are monitored periodically. Seven children had prenatal diagnosis, in five the shunt closed spontaneously. Nine children were symptomatic in their evolution (hyperammonemia, regenerative nodules, cholestasis, gastrointestinal bleeding). Of these, in five we performed balloon test occlusion, tolerated in all patients, followed by radiological closure. In our experience, the advancement of interventional radiology techniques avoided surgery to close the shunt. Morphologically, the CPSS is extremely heterogeneous, with multiple possible connections established. CPSS has multiple clinical presentations, from asymptomatic patients to acute liver failure. The therapeutic approach should be individualized and therefore held in overspecialized centers. Georg Thieme Verlag KG Stuttgart · New York.

  17. Clinical and radiologic manifestations of congenital extrahepatic portosystemic shunts: a comprehensive review.

    PubMed

    Alonso-Gamarra, Eduardo; Parrón, Manuel; Pérez, Ana; Prieto, Consuelo; Hierro, Loreto; López-Santamaría, Manuel

    2011-01-01

    Congenital extrahepatic portosystemic shunt (CEPS) is a rare condition in which the portomesenteric blood drains into a systemic vein, bypassing the liver through a complete or partial shunt. Most often, the diagnosis is made primarily with Doppler ultrasonography. Computed tomographic angiography and magnetic resonance angiography are used for further classification of the shunt and assessment of accompanying anomalies. Conventional angiography is necessary when results of the other tests disagree or are inconclusive. CEPS is classified into two types according to the pattern of anastomoses between the portal vein and systemic vein. In type 1, intrahepatic portal venous supply is absent; in type 2, intrahepatic portal venous supply is preserved. Type 1 usually occurs in girls with associated malformations, such as situs ambiguous with polysplenia and congenital heart defects. Associated anomalies are less frequent in type 2, and symptoms usually develop later without a gender preference. Hepatic encephalopathy and liver dysfunction are possible complications of both types and usually develop during adulthood. Both types are also associated with regenerative hepatic nodules. The clinical setting and imaging appearance of these nodules can help one avoid misdiagnosis. Definitive treatment of CEPS is determined by the type of shunt. Liver transplantation is the only effective treatment for symptomatic type 1 CEPS; surgical closure or embolization of the shunt is the therapeutic approach for type 2. Copyright © RSNA, 2011.

  18. Circuit analysis method for thin-film solar cell modules

    NASA Technical Reports Server (NTRS)

    Burger, D. R.

    1985-01-01

    The design of a thin-film solar cell module is dependent on the probability of occurrence of pinhole shunt defects. Using known or assumed defect density data, dichotomous population statistics can be used to calculate the number of defects expected in a module. Probability theory is then used to assign the defective cells to individual strings in a selected series-parallel circuit design. Iterative numerical calculation is used to calcuate I-V curves using cell test values or assumed defective cell values as inputs. Good and shunted cell I-V curves are added to determine the module output power and I-V curve. Different levels of shunt resistance can be selected to model different defect levels.

  19. Congenital veno-venous malformations of the liver: widely variable clinical presentations.

    PubMed

    Witters, Peter; Maleux, Geert; George, Christophe; Delcroix, Marion; Hoffman, Ilse; Gewillig, Marc; Verslype, Chris; Monbaliu, Diethard; Aerts, Raymond; Pirenne, Jacques; Van Steenbergen, Werner; Nevens, Frederik; Fevery, Johan; Cassiman, David

    2008-08-01

    Congenital portosystemic veno-venous malformations are rare abnomalities that often remain undiagnosed. Typically they are classified by their anatomical characteristics according to Morgan (extrahepatic, Abernethy malformations type Ia,b and II) and Park (intrahepatic, types 1-4). However, their clinical presentation is less dependent on the anatomical type. We reviewed the clinical characteristics of six cases drawn from our files (from 1970 to 2006). One patient, a 25-year-old male, had extrahepatic shunting whereby the liver receives only arterial blood because the portal vein (PV) connects with the inferior caval vein (ICV) (Abernethy Ib); he presented with episodes of jaundice and pruritus. Three patients had extrahepatic shunting with patent intrahepatic portal veins, but with shunting of splenomesenterial blood towards the ICV (Abernethy II); these included a 66-year-old male with hepatic encephalopathy, a 17-year-old female with (porto?-)pulmonary hypertension without portal hypertension, and a 33-year-old female with epidsodes of acute pain secondary to spontaneous bleeding within a primary liver tumor. Two patients had intrahepatic shunting; these included an 8-year-old boy who was diagnosed incidentally during work-up for abnormal liver enzymes with a communication between right PV and ICV (Park type 1), and a 59-year-old male with multiple PV-ICV-shunts in several liver segments (Park, type 4) who presented with hepatic encephalopathy. Patients often present with signs of hepatic shunting (encephalopathy, pulmonary hypertension, hepatopulmonary syndrome, and/or hypoglycemia) with relative sparing of the synthetic liver function in the absence of portal hypertension. Some shunts present with space-occupying lesions (focal nodular hyperplasia, hepatocellular carcinoma, nodular regenerative hyperplasia, etc.) or biliary atresia. Finally, some cases are detected incidentally.

  20. Reversible Venting Stitch for Fenestrating Valve-less Glaucoma Shunts.

    PubMed

    Akil, Handan; Vu, Priscilla Q; Nguyen, Anhtuan H; Nugent, Alexander; Chopra, Vikas; Francis, Brian A; Tan, James C

    2017-12-01

    The purpose of this is to describe a venting stitch modification for valveless glaucoma aqueous shunts and characterize early postoperative intraocular pressure (IOP) and glaucoma medication use following the modification. Retrospective chart review of 61 sequential patients undergoing Baerveldt glaucoma implant (BGI)-350 implantation at the Doheny Eye Institute. Twenty-four patients received a glaucoma shunt with venting stitch modification (modified BGI) and 37 patients received an unmodified shunt (BGI-only). IOP, number of glaucoma medications, and number of hypotony cases (intraocular pressure ≤5 mm Hg) were compared between the groups. T-tests were used for statistical analysis. At postoperative-day 1, mean IOP was significantly lower compared with preoperatively in the modified BGI group (14 mm Hg; reduced by 51%; P<0.0001) but not the BGI-only group (27 mm Hg; P=0.06). IOP difference between groups persisted till immediately before tube opening (P=0.005) and fewer IOP-lowering medications needed in the modified BGI group (P<0.0001). One case (4.2%) of postoperative hypotony was encountered with BGI modification, which resolved after the stitch was removed in clinic. The venting stitch valveless shunt modification allows for effective, reliable, and safe control of early postoperative IOP.

  1. Magnetic resonance spectroscopic determination of a neuronal and axonal marker in white matter predicts reversibility of deficits in secondary normal pressure hydrocephalus

    PubMed Central

    Shiino, A; Nishida, Y; Yasuda, H; Suzuki, M; Matsuda, M; Inubushi, T

    2004-01-01

    Background: Normal pressure hydrocephalus (NPH) is considered to be a treatable form of dementia, because cerebrospinal fluid (CSF) shunting can lessen symptoms. However, neuroimaging has failed to predict when shunting will be effective. Objective: To investigate whether 1H (proton) magnetic resonance (MR) spectroscopy could predict functional outcome in patients after shunting. Methods: Neurological state including Hasegawa's dementia scale, gait, continence, and the modified Rankin scale were evaluated in 21 patients with secondary NPH who underwent ventriculo-peritoneal shunting. Outcomes were measured postoperatively at one and 12 months and were classified as excellent, fair, or poor. MR spectra were obtained from left hemispheric white matter. Results: Significant preoperative differences in N-acetyl aspartate (NAA)/creatine (Cr) and NAA/choline (Cho) were noted between patients with excellent and poor outcome at one month (p = 0.0014 and 0.0036, respectively). Multiple regression analysis linked higher preoperative NAA/Cr ratio, gait score, and modified Rankin scale to better one month outcome. Predictive value, sensitivity, and specificity for excellent outcome following shunting were 95.2%, 100%, and 87.5%. Multiple regression analysis indicated that NAA/Cho had the best predictive value for one year outcome (p = 0.0032); predictive value, sensitivity, and specificity were 89.5%, 90.0%, and 88.9%. Conclusions: MR spectroscopy predicted long term post-shunting outcomes in patients with secondary NPH, and it would be a useful assessment tool before lumbar drainage. PMID:15258216

  2. Congenital portosystemic shunts with and without gastrointestinal bleeding - case series.

    PubMed

    Gong, Ying; Zhu, Hui; Chen, Jun; Chen, Qi; Ji, Min; Pa, Mier; Zheng, Shan; Qiao, Zhongwei

    2015-12-01

    The clinical presentation of congenital portosystemic shunt is variable and gastrointestinal bleeding is an uncommon presentation. To describe the imaging features of congenital portosystemic shunt as it presented in 11 children with (n = 6) and without gastrointestinal bleeding (n = 5). We performed a retrospective study on a clinical and imaging dataset of 11 children diagnosed with congenital portosystemic shunt. A total of 11 children with congenital portosystemic shunt were included in this study, 7 with extrahepatic portosystemic shunts and 4 with intrahepatic portosystemic shunts. Six patients with gastrointestinal bleeding had an extrahepatic portosystemic shunt, and the imaging results showed that the shunts originated from the splenomesenteric junction (n = 5) or splenic vein (n = 1) and connected to the internal iliac vein. Among the five cases of congenital portosystemic shunt without gastrointestinal bleeding, one case was an extrahepatic portosystemic shunt and the other four were intrahepatic portosystemic shunts. Most congenital portosystemic shunt patients with gastrointestinal bleeding had a shunt that drained portal blood into the iliac vein via an inferior mesenteric vein. This type of shunt was uncommon, but the concomitant rate of gastrointestinal bleeding with this type of shunt was high.

  3. Penile artery shunt syndrome: a novel cause of erectile dysfunction after penile revascularization surgery.

    PubMed

    Pavlinec, Jonathan G; Hakky, Tariq S; Yang, Christopher; Massis, Kamal; Munarriz, Ricardo; Carrion, Rafael E

    2014-09-01

    Penile revascularization is a surgical treatment option for erectile dysfunction (ED) in healthy individuals due to a focal arterial occlusion in the absence of generalized vascular disease. Most described failures have been attributed to graft stenosis or disruption of the anastomosis. We report a novel phenomenon called Penile Artery Shunt Syndrome that contributed to persistent ED in a patient after penile microvascular arterial bypass surgery. A 26-year-old man presented for evaluation of long-standing ED, which was attributed to trauma sustained 12 years earlier. He had difficulty obtaining and maintaining erections despite oral pharmacotherapy. Clinical data related to the case were studied, analyzed, and reviewed with urologic and radiologic specialists at multiple centers that collaborated in the care of this patient. Penile duplex ultrasound peak systolic velocities and five-item International Index for Erectile Function questionnaire scores were the main outcome measures. Initial diagnostic workup of the patient confirmed severe insufficiency of the left cavernosal artery, with no evidence of venous leak. The patient underwent penile microvascular arterial bypass surgery with anastomosis of the left inferior epigastric artery to the left dorsal penile artery. The patient had persistence of severe ED despite patent anastomosis by penile duplex ultrasound. Subsequent arteriography revealed an arterial shunt due to an aberrant obturator artery arising from the donor inferior epigastric artery. The patient underwent embolization of the aberrant obturator artery, with resolution of the shunt and marked improvement in erectile function. The presence of an aberrant obturator artery arising from the inferior epigastric artery may predispose to persistent ED after revascularization due to the creation of a shunt phenomenon. Pelvic arteriography may be useful in identifying anomalous anatomic considerations prior to penile revascularization and to evaluate patients with persistent postoperative ED. © 2014 International Society for Sexual Medicine.

  4. Two Distinct Aerobic Methionine Salvage Pathways Generate Volatile Methanethiol in Rhodopseudomonas palustris

    PubMed Central

    Miller, Anthony R.; North, Justin A.; Wildenthal, John A.

    2018-01-01

    ABSTRACT 5′-Methyl-thioadenosine (MTA) is a dead-end, sulfur-containing metabolite and cellular inhibitor that arises from S-adenosyl-l-methionine-dependent reactions. Recent studies have indicated that there are diverse bacterial methionine salvage pathways (MSPs) for MTA detoxification and sulfur salvage. Here, via a combination of gene deletions and directed metabolite detection studies, we report that under aerobic conditions the facultatively anaerobic bacterium Rhodopseudomonas palustris employs both an MTA-isoprenoid shunt identical to that previously described in Rhodospirillum rubrum and a second novel MSP, both of which generate a methanethiol intermediate. The additional R. palustris aerobic MSP, a dihydroxyacetone phosphate (DHAP)-methanethiol shunt, initially converts MTA to 2-(methylthio)ethanol and DHAP. This is identical to the initial steps of the recently reported anaerobic ethylene-forming MSP, the DHAP-ethylene shunt. The aerobic DHAP-methanethiol shunt then further metabolizes 2-(methylthio)ethanol to methanethiol, which can be directly utilized by O-acetyl-l-homoserine sulfhydrylase to regenerate methionine. This is in contrast to the anaerobic DHAP-ethylene shunt, which metabolizes 2-(methylthio)ethanol to ethylene and an unknown organo-sulfur intermediate, revealing functional diversity in MSPs utilizing a 2-(methylthio)ethanol intermediate. When MTA was fed to aerobically growing cells, the rate of volatile methanethiol release was constant irrespective of the presence of sulfate, suggesting a general housekeeping function for these MSPs up through the methanethiol production step. Methanethiol and dimethyl sulfide (DMS), two of the most important compounds of the global sulfur cycle, appear to arise not only from marine ecosystems but from terrestrial ones as well. These results reveal a possible route by which methanethiol might be biologically produced in soil and freshwater environments. PMID:29636438

  5. Transjugular Intrahepatic Portosystemic Shunt Placement in Patients with Cirrhosis and Concomitant Portal Vein Thrombosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ha, Thuong G. Van, E-mail: tgvanha@radiology.bsd.uchicago.edu; Hodge, Justin; Funaki, Brian

    2006-10-15

    Purpose. To determine the safety and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) creation in patients with liver cirrhosis complicated by thrombosed portal vein. Methods. This study reviewed 15 cases of TIPS creation in 15 cirrhotic patients with portal vein thrombosis at our institution over an 8-year period. There were 2 women and 13 men with a mean age of 53 years. Indications were refractory ascites, variceal hemorrhage, and refractory pleural effusion. Clinical follow-up was performed in all patients. Results. The technical success rate was 75% (3/4) in patients with chronic portal vein thrombosis associated with cavernomatous transformation and 91%more » (10/11) in patients with acute thrombosis or partial thrombosis, giving an overall success rate of 87%. Complications included postprocedural encephalopathy and localized hematoma at the access site. In patients with successful shunt placement, the total follow-up time was 223 months. The 30-day mortality rate was 13%. Two patients underwent liver transplantation at 35 days and 7 months, respectively, after TIPS insertion. One patient had an occluded shunt at 4 months with an unsuccessful revision. The remaining patients had functioning shunts at follow-up. Conclusion. TIPS creation in thrombosed portal vein is possible and might be a treatment option in certain patients.« less

  6. Intrinsically shunted Josephson junctions for electronics applications

    NASA Astrophysics Data System (ADS)

    Belogolovskii, M.; Zhitlukhina, E.; Lacquaniti, V.; De Leo, N.; Fretto, M.; Sosso, A.

    2017-07-01

    Conventional Josephson metal-insulator-metal devices are inherently underdamped and exhibit hysteretic current-voltage response due to a very high subgap resistance compared to that in the normal state. At the same time, overdamped junctions with single-valued characteristics are needed for most superconducting digital applications. The usual way to overcome the hysteretic behavior is to place an external low-resistance normal-metal shunt in parallel with each junction. Unfortunately, such solution results in a considerable complication of the circuitry design and introduces parasitic inductance through the junction. This paper provides a concise overview of some generic approaches that have been proposed in order to realize internal shunting in Josephson heterostructures with a barrier that itself contains the desired resistive component. The main attention is paid to self-shunted devices with local weak-link transmission probabilities that are so strongly disordered in the interface plane that transmission probabilities are tiny for the main part of the transition region between two super-conducting electrodes, while a small part of the interface is well transparent. We discuss the possibility of realizing a universal bimodal distribution function and emphasize advantages of such junctions that can be considered as a new class of self-shunted Josephson devices promising for practical applications in superconducting electronics operating at 4.2 K.

  7. [Small-diameter portosystemic shunts: indications and limitations].

    PubMed

    Angel Mercado, M; Granados-García, J; Barradas, F; Chan, C; Contreras, J L; Orozco, H; Angel-Mercado, M

    1998-01-01

    Low diameter porto-systemic shunts for the treatment of portal hypertension bleeding have emerged as a consequence of the technical development of vascular grafts (PTFE) that allow the use of a narrow lumen. The experience with this kind of operation at the Instituto Nacional de la Nutrición Salvador Zubirán, Mexico City during a 6-year period is reported. There were twenty-seven patients with good liver function (Child-Pugh A-B) were operated or electively, average Age 47.5 years (range 17-71), twenty three patients with liver cirrhosis, one with portal fibrosis and three with idiopathic portal hypertension. Operative mortality: 4%. Rebleeding: 14%. Postoperative encephalopathy was observed in 14 of 27, three of them being grade III-IV (11%). In the remaining 11 cases, it was mild and easily controlled. Postoperative angiography showed shunt patency in 81% of the cases; in 33% of the cases, portal vein diameter reduction was shown, as well as two cases with portal vein thrombosis. In 77% of the cases, adequate postoperative quality of life was observed. Survival (Kaplan-Meier): 86% at 12 months and 56% at 60 months. These kinds of shunts are a good alternate choice for patients considered for surgery, in which other portal blood flow preserving procedures (selective shunts, devascularization with transection) are not feasible.

  8. A Resonant Damping Study Using Piezoelectric Materials

    NASA Technical Reports Server (NTRS)

    Min, J. B.; Duffy, K. P.; Choi, B. B.; Morrison, C. R.; Jansen, R. H.; Provenza, A. J.

    2008-01-01

    Excessive vibration of turbomachinery blades causes high cycle fatigue (HCF) problems requiring damping treatments to mitigate vibration levels. Based on the technical challenges and requirements learned from previous turbomachinery blade research, a feasibility study of resonant damping control using shunted piezoelectric patches with passive and active control techniques has been conducted on cantilever beam specimens. Test results for the passive damping circuit show that the optimum resistive shunt circuit reduces the third bending resonant vibration by almost 50%, and the optimum inductive circuit reduces the vibration by 90%. In a separate test, active control reduced vibration by approximately 98%.

  9. Normal pressure hydrocephalus in patients with myelomeningocele.

    PubMed

    Hammock, M K; Milhorat, T H; Baron, I S

    1976-01-01

    Although the syndrome of normal pressure hydrocephalus (NPH) was described in the adult as early as 1964, it has only recently been recognized in the child. In this preliminary report, eight myelomeningocele patients with presumed NPH were evaluated before and after ventricular shunting procedures. Cranial computed tomography and serial psychological testing have proved to be particularly valuable both in the pre-operative and post-operative assessment of these patients and have the distinct advantage of being simple, non-invasive diagnostic measures. Continuous intra-ventricular pressure monitoring has shown what promises to be characteristic elevated pressure plateaux imposed on normal baseline cerebrospinal fluid (CSF) pressures in so-called NPH but is a more difficult clinical procedure, necessarily associated with potential complications. Although decreasing response to growth-stimulating hormone can be demonstrated in patients with long-standing hydrocephalus, this endocrine malfunction cannot be considered an early indicator of intracranial pathology. Single IQ scores are inadequate measures of intellectural function in children with NPH and serial examinations should be carried out. Detailed neuropsychological testing will document performance IQ scores well below verbal IQ scores and will generally show failure of psychomotor development to keep pace with chronological ageing. Initial studies indicate that improved performance scores can be expected within 1 1/2 to 3 months following successful ventricular shunting operations, and that any downward trend in pre-operative test scoring can at least be reversed. Statistically significant improvements in full-scale IQ scores have not been seen, however, before the end of the first post-operative year. Clinically, improved attentiveness and sociability, and decreased spasticity (if present prior to surgery) can be expected following shunting. Over-all, ventriculomegaly, normal CSF pressure, stable head size, and non-progressive neurological symptoms cannot be regarded as sufficient criteria for the diagnosis of an arrested state of hydrocephalus, and should suggest NPH, especially in those children who demonstrate a discrepancy between performance and verbal IQ scores and who fail to exhibit continuing psychomotor development with advancing age.

  10. Glaucoma in patients with shunt-treated normal pressure hydrocephalus.

    PubMed

    Gallina, Pasquale; Savastano, Alfonso; Becattini, Eleonora; Orlandini, Simone; Scollato, Antonio; Rizzo, Stanislao; Carreras, Giulia; Di Lorenzo, Nicola; Porfirio, Berardino

    2017-11-17

    OBJECTIVE Changes in the pressure gradient between intraocular and intracranial compartments at the lamina cribrosa level are a possible explanation of normal tension glaucoma (NTG). Shunt-treated normal pressure hydrocephalus (NPH) is a model for testing whether the increase (time from disease onset to CSF shunt placement, i.e., "protection period") and decrease (time from shunt placement to observation, i.e., "exposure period") in intracranial pressure (ICP) are glaucoma protective or risk factors, respectively. The authors estimated the prevalence of NTG in patients with shunt-treated NPH and calculated the extent of optic nerve exposure to changes in the trans-lamina cribrosa gradient. METHODS Data obtained in patients with NPH who had undergone ventriculoperitoneal (VP) shunt placement were analyzed. Patients with more than 6 months' follow-up, no pathologies associated with ICP changes or CSF dynamics disturbances, and no surgical or valve-related complications were scheduled for ophthalmic evaluation. RESULTS Nine of 22 patients had NTG, which is about a 40-fold increase in rate compared with the rate in the general elderly population without hydrocephalus (p < 0.001). The median protection period was 12.0 months in patients with NTG and 18.0 months in those without NTG (p = 0.033). The median ICP decrease multiplied by duration of exposure in months was 76.0 mm Hg × months in the NTG group and 24.1 mm Hg × months in the no-NTG group (p = 0.048). The patients' median adjusted age (adjusted for "protection" and "exposure" times) was 85.1 years in the NTG group and 78.8 years in the no-NTG group (p = 0.001). CONCLUSIONS A crucial risk factor for development of NTG in patients with shunt-treated NPH is the duration of optic nerve exposure to the lowering of ICP. Patients with NPH who are candidates for CSF shunting should be informed of the risk of incurring glaucoma. Longitudinal studies could provide estimates of tolerated times for a given ICP decrease.

  11. A disorder-based strategy for tunable, broadband wave attenuation

    NASA Astrophysics Data System (ADS)

    Zhang, Weiting; Celli, Paolo; Cardella, Davide; Gonella, Stefano

    2017-04-01

    One of the most daunting limitations of phononic crystals and acoustic/elastic metamaterials is their passivity: a given configuration is bound to display its phononic properties only around its design point, i.e., working at some pre-determined operating conditions. In the past decade, this shortcoming has inspired the design of phononic media with tunable wave characteristics; noteworthy results have been obtained through a family of methodologies involving shunted piezoelectric elements. Shunting a piezoelectric element means connecting it to a passive electric circuit; tunability stems from the ability to modify the effective mechanical properties of the piezoelectric medium by modifying the circuit characteristics. One of the most popular shunting circuits is the resistor-inductor, which allows the patch-and-shunt system to behave as an electromechanical resonator. A common motif among the works employing shunted piezos for phononic control is periodicity: the patches are typically periodically placed in the domain and the circuits are identically tuned. The objective of this work is to demonstrate that the wave attenuation performance of structures with shunted piezoelectric patches can be improved by leveraging notions of organized disorder. Based on the idea of rainbow trapping broadband wave attenuation obtained by tuning an array of resonators at distinct neighboring frequencies we design and test an electromechanical waveguide structure capable of attenuating waves over broad frequency ranges. In order to emphasize the fact that periodicity is not a binding requirement when working with RL shunts (which induce locally resonant bandgaps), we report on the performance of random arrangements of patches. In an attempt to demonstrate the tunability attribute of our strategy, we take advantage of the reconfigurability of the circuits to show how a single waveguide can attenuate both waves and vibrations over different frequency ranges.

  12. Prospective estimation of mean axon diameter and extra-axonal space of the posterior limb of the internal capsule in patients with idiopathic normal pressure hydrocephalus before and after a lumboperitoneal shunt by using q-space diffusion MRI.

    PubMed

    Hori, Masaaki; Kamiya, Kouhei; Nakanishi, Atsushi; Fukunaga, Issei; Miyajima, Masakazu; Nakajima, Madoka; Suzuki, Michimasa; Suzuki, Yuriko; Irie, Ryusuke; Kamagata, Koji; Arai, Hajime; Aoki, Shigeki

    2016-09-01

    To prospectively estimate the mean axon diameter (MAD) and extracellular space of the posterior limb of the internal capsule (PLIC) in patients with idiopathic normal pressure hydrocephalus (iNPH) before and after a lumboperitoneal (LP) shunting operation using q-space diffusion MRI analysis. We studied 12 consecutive patients with iNPH and 12 controls at our institution. After conventional magnetic resonance imaging (MRI), q-space image (QSI) data were acquired with a 3-T MRI scanner. The MAD and extra-axonal space of the PLIC before and after LP shunting were calculated using two-component q-space imaging analyses; the before and after values were compared. After LP shunt surgery, the extracellular space of the PLIC was significantly higher than that of the same patients before the operation (one-way analysis of variance (ANOVA) with Scheffé's post-hoc test, P = 0.024). No significant differences were observed in the PLIC axon diameters among normal controls or in patients before and after surgery. Increases in the root mean square displacement in the extra-axonal space of the PLIC in patients with iNPH after an LP shunt procedure are associated with the microstructural changes of white matter and subsequent abatement of patient symptoms. • Q-space diffusion MRI provides information on microstructural changes in the corticospinal tract • Lumboperitoneal (LP) shunting operation is useful for idiopathic normal pressure hydrocephalus • Q-space measurement may be a biomarker for the effect of the LP shunt procedure.

  13. Cerebrospinal Fluid Shunting Complications in Children

    PubMed Central

    Hanak, Brian W.; Bonow, Robert H.; Harris, Carolyn A.; Browd, Samuel R.

    2018-01-01

    Although cerebrospinal fluid (CSF) shunt placement is the most common procedure performed by pediatric neurosurgeons, shunts remain among the most failure-prone life-sustaining medical devices implanted in modern medical practice. This article provides an overview of the mechanisms of CSF shunt failure for the 3 most commonly employed definitive CSF shunts in the practice of pediatric neurosurgery: ventriculoperitoneal, ventriculopleural, and ventriculoatrial. The text has been partitioned into the broad modes of shunt failure: obstruction, infection, mechanical shunt failure, overdrainage, and distal catheter site-specific failures. Clinical management strategies for the various modes of shunt failure are discussed as are research efforts directed towards reducing shunt complication rates. As it is unlikely that CSF shunting will become an obsolete procedure in the foreseeable future, it is incumbent on the pediatric neurosurgery community to maintain focused efforts to improve our understanding of and management strategies for shunt failure and shunt-related morbidity. PMID:28249297

  14. Comparison of anti-siphon devices-how do they affect CSF dynamics in supine and upright posture?

    PubMed

    Gehlen, Manuel; Eklund, Anders; Kurtcuoglu, Vartan; Malm, Jan; Schmid Daners, Marianne

    2017-08-01

    Three different types of anti-siphon devices (ASDs) have been developed to counteract siphoning-induced overdrainage in upright posture. However, it is not known how the different ASDs affect CSF dynamics under the complex pressure environment seen in clinic due to postural changes. We investigated which ASDs can avoid overdrainage in upright posture best without leading to CSF accumulation. Three shunts each of the types Codman Hakim with SiphonGuard (flow-regulated), Miethke miniNAV with proSA (gravitational), and Medtronic Delta (membrane controlled) were tested. The shunts were compared on a novel in vitro setup that actively emulates the physiology of a shunted patient. This testing method allows determining the CSF drainage rates, resulting CSF volume, and intracranial pressure in the supine, sitting, and standing posture. The flow-regulated ASDs avoided increased drainage by closing their primary flow path when drainage exceeded 1.39 ± 0.42 mL/min. However, with intraperitoneal pressure increased in standing posture, we observed reopening of the ASD in 3 out of 18 experiment repetitions. The adjustable gravitational ASDs allow independent opening pressures in horizontal and vertical orientation, but they did not provide constant drainage in upright posture (0.37 ± 0.03 mL/min and 0.26 ± 0.03 mL/min in sitting and standing posture, respectively). Consequently, adaptation to the individual patient is critical. The membrane-controlled ASDs stopped drainage in upright posture. This eliminates the risk of overdrainage, but leads to CSF accumulation up to the volume observed without shunting when the patient is upright. While all tested ASDs reduced overdrainage, their actual performance will depend on a patient's specific needs because of the large variation in the way the ASDs influence CSF dynamics: while the flow-regulated shunts provide continuous drainage in upright posture, the gravitational ASDs allow and require additional adaptation, and the membrane-controlled ASDs show robust siphon prevention by a total stop of drainage.

  15. An overview of the literature on congenital lower urinary tract obstruction and introduction to the PLUTO trial: percutaneous shunting in lower urinary tract obstruction.

    PubMed

    Morris, R Katie; Kilby, Mark D

    2009-02-01

    Congenital lower urinary tract obstruction (LUTO) comprises a heterogeneous group of pathologies causing obstruction to the urethra, the most common being posterior urethral valves. Such pathology is often associated with high perinatal mortality and varying degrees of perinatal and infant morbidity. A high proportion of LUTO may be visualised during routine second trimester (and first trimester) ultrasound giving rise to the possibility of determining individual fetal prognosis and treatments such as vesico-amniotic shunting, with a view to altering pathogenesis. The aims of the percutaneous shunting in low urinary tract obstruction (PLUTO) trial are to determine the effectiveness of these treatments and accuracy of the investigations with the primary outcome measures being perinatal mortality and postnatal renal function.

  16. Cardiac resynchronisation therapy in the presence of left-to-right intracardiac shunting: more good than harm?

    PubMed

    Kyu, Kyu; Seow, Swee Chong; Wong, Raymond; Kojodjojo, Pipin

    2016-03-17

    An elderly Chinese man with moderately impaired left ventricular function, left bundle branch block and ST-elevation myocardial infarction complicated by ventricular septal rupture had class IV heart failure symptoms refractory to medical and surgical interventions. As a treatment of last resort, a cardiac resynchronisation therapy (CRT) pacemaker was implanted apprehensively, as preoperative concerns were raised whether CRT could exacerbate left-to-right shunting, hence negating the potential benefits of CRT. Introduction of CRT significantly improved the patient's haemodynamic status and symptoms, allowing for successful discharge home. To the best of our knowledge, this is the first report of a patient with severely symptomatic acute heart failure, widened QRS and active left-to-right intracardiac shunting, treated successfully with CRT. 2016 BMJ Publishing Group Ltd.

  17. Quantification of abnormal intracranial pressure waves and isotope cisternography for diagnosis of occult communicating hydrocephalus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cardoso, E.R.; Piatek, D.; Del Bigio, M.R.

    1989-01-01

    Nineteen consecutive patients with suspected occult communicating hydrocephalus were investigated by means of clinical evaluation, neuropsychological testing, isotope cisternography, computed tomography scanning, and continuous intracranial pressure monitoring. Semi-quantitative grading systems were used in the evaluation of the clinical, neuropsychological, and cisternographic assessments. Clinical examination, neuropsychological testing, and computed tomography scanning were repeated 3 months after ventriculoperitoneal shunting. All patients showed abnormal intracranial pressure waves and all improved after shunting. There was close correlation between number, peak, and pulse pressures of B waves and the mean intracranial pressure. However, quantification of B waves by means of number, frequency, and amplitude didmore » not help in predicting the degree of clinical improvement postshunting. The most sensitive predictor of favorable response to shunting was enlargement of the temporal horns on computed tomography scan. Furthermore, the size of temporal horns correlated with mean intracranial pressure. There was no correlation between abnormalities on isotope cisternography and clinical improvement.« less

  18. Ultrasound guided placement of the distal catheter in paediatric ventriculoatrial shunts-an appraisal of efficacy and complications.

    PubMed

    Clark, David J; Chakraborty, Aabir; Roebuck, Derek J; Thompson, Dominic N P

    2016-07-01

    Ventriculoatrial (VA) shunts are commonly used as a second-line treatment of hydrocephalus when the peritoneum is an unsuitable site for the distal catheter. Many centres now utilise ultrasound and interventional radiology techniques to aid placement of the distal catheter. The purpose of this study was to conduct a contemporary audit of VA shunting in children using interventional radiology techniques for placement of the distal catheter. A retrospective analysis of all patients who had VA shunts inserted between June 2000 and June 2010 was conducted using a prospectively updated surgical database and case notes review. Ninety-four VA shunts were inserted in 38 patients. Thirty-seven patients had been treated initially with ventriculoperitoneal (VP) shunts. Twenty-two patients required at least 1 shunt revision (58 %). The 6-month, 1- and 2-year shunt survival rates were 53, 43 and 27 %, respectively. Blockage was the commonest reason for shunt failure (68 %). The site of failure was proximal (ventricular catheter +/- valve) in 32 % and distal (atrial catheter) in 21 % of cases. The overall infection rate was 6 % per procedure and 11 % per patient. There were 7 deaths, of which 3 were shunt related. VA shunting provides a viable second-line option for shunt placement in complex hydrocephalus. The causes of shunt failure (blockage, infection and equipment failure) are similar to VP shunting though shunt survival rates are inferior to VP shunts. Ultrasound guided VA shunt placement provides a relatively safe, second-line alternative to the placement of a ventriculoperitoneal shunt when this route is unsuitable.

  19. Priapism caused by 'Tribulus terrestris'.

    PubMed

    Campanelli, M; De Thomasis, R; Tenaglia, R L

    2016-01-01

    A 36-year-old Caucasian man was diagnosed with a 72-h-lasting priapism that occurred after the assumption of a Herbal supplement based on Tribulus terrestris, which is becoming increasingly popular for the treatment of sexual dysfunction. The patient underwent a cavernoglandular shunt (Ebbehoj shunt) in order to obtain complete detumescence, from which derived negative post-episode outcomes on sexual function. All patients consuming non-FDA-approved alternative supplements such as Tribulus terrestris should be warned about the possible serious side effects.

  20. Motor pattern of the sphincter of Oddi in patients with bilioenteric shunt: a manometric study.

    PubMed

    Ponce, J; Garrigues, V; Pertejo, V; Sala, T; Berenguer, J

    1988-10-01

    An endoscopic biliary manometry was performed on 11 patients with a surgical bilioenteric shunt--choledochoduodenostomy--and no pressure gradient between common bile duct and duodenum. Basal pressure and frequency of the phasic waves of the sphincter of Oddi were significantly higher in these patients than in controls or in patients with retained common bile duct stones. These results suggest a functional adaptation of the sphincter of Oddi in an attempt to recover the normal pressure in the biliary tract.

  1. Outcomes of systemic to pulmonary artery shunts in patients weighing less than 3 kg: analysis of shunt type, size, and surgical approach.

    PubMed

    Myers, John W; Ghanayem, Nancy S; Cao, Yumei; Simpson, Pippa; Trapp, Katie; Mitchell, Michael E; Tweddell, James S; Woods, Ronald K

    2014-02-01

    To evaluate outcomes of systemic to pulmonary artery shunts (SPS) in patients weighing less than 3 kg with regard to shunt type, shunt size, and surgical approach. Patients weighing less than 3 kg who underwent modified Blalock-Taussig or central shunts with polytetrafluoroethylene grafts at our institution from January 1, 2000, to May 31, 2011, were reviewed. Patients who had undergone other major concomitant procedures were excluded from the analysis. Primary outcomes included mortality (discharge mortality and mortality before next planned palliative procedure or definitive repair), cardiac arrest and/or extracorporeal membrane oxygenation (ECMO), and shunt reintervention. In this cohort of 80 patients, discharge survival was 96% (77/80). Postoperative cardiac arrest or ECMO occurred in 6/80 (7.5%), and shunt reintervention was required in 14/80 (17%). On univariate analysis, shunt reintervention was more common in patients with 3-mm shunts (11/30, 37%) compared with 3.5-mm (2/36, 6%) or 4-mm shunts (1/14, 7%) (P < .003). There were no statistically significant associations between shunt type, shunt size, or surgical approach and cardiac arrest/ECMO or mortality. Multiple logistic regression demonstrated that a shunt size of 3 mm (P = .019) and extracardiac anomaly (P = .047) were associated with shunt reintervention, whereas no variable was associated with cardiac arrest/ECMO or mortality. In this high-risk group of neonates weighing less than 3 kg at the time of SPS, survival to discharge and the next planned surgical procedure was high. Outcomes were good with the 3.5- and 4-mm shunts; however, shunt reintervention was common with 3-mm shunts. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  2. Periodic shunted arrays for the control of noise radiation in an enclosure

    NASA Astrophysics Data System (ADS)

    Casadei, Filippo; Dozio, Lorenzo; Ruzzene, Massimo; Cunefare, Kenneth A.

    2010-08-01

    This work presents numerical and experimental investigations of the application of a periodic array of resistive-inductive (RL) shunted piezoelectric patches for the attenuation of broadband noise radiated by a flexible plate in an enclosed cavity. A 4×4 lay-out of piezoelectric patches is bonded to the surface of a rectangular plate fully clamped to the top face of a rectangular cavity. Each piezo-patch is shunted through a single RL circuit, and all shunting circuits are tuned at the same frequency. The response of the resulting periodic structure is characterized by frequency bandgaps where vibrations and associated noise are strongly attenuated. The location and extent of induced bandgaps are predicted by the application of Bloch theorem on a unit cell of the periodic assembly, and they are controlled by proper selection of the shunting circuit impedance. A coupled piezo-structural-acoustic finite element model is developed to evaluate the noise reduction performance. Strong attenuation of multiple panel-controlled modes is observed over broad frequency bands. The proposed concept is tested on an aluminum plate mounted in a wooden box and driven by a shaker. Experimental results are presented in terms of pressure responses recorded using a grid of microphones placed inside the acoustic box.

  3. Evidence for biochemical and physiological differences between enzyme genotypes in Drosophila melanogaster.

    PubMed Central

    Cavener, D R; Clegg, M T

    1981-01-01

    The in vivo flux of carbon through the pentose shunt is investigated as a function of different 6-phosphogluconate dehydrogenase (6Pgd) and glucose-6-phosphate dehydrogenase (G6pd) genotypes by using differential radioactive labeling of the C-1 and C-6 positions of glucose. Alternative 6Pgd-G6pd genotypes are shown to differ in relative in vivo carbon flux through the pentose shunt. The relative in vitro specific activity differences between the 6PgdSS and 6PgdFF genotypes appear to be primarily responsible for these differences. In addition, the pentose-shunt activity is correlated with the rate of lipid synthesis. This correlation is consistent with the major metabolic function of the pathway, which is to produce NADPH for lipid synthesis. Taken together, the results of these experiments show that different genotypes of 6Pgd are associated with measurable biochemical and physiological differences. Higher order phenotypic differences of this kind must be demonstrated to support the hypothesis that natural selection can discriminate among allozymes of a given genetic locus. PMID:6794031

  4. Programmable shunt valve interactions with osseointegrated hearing devices.

    PubMed

    Pierson, Matthew J; Wehrmann, Daniel; Albers, J Andrew; El Tecle, Najib E; Costa, Dary; Elbabaa, Samer K

    2017-04-01

    OBJECTIVE Patients with ventriculoperitoneal (VP) shunts with programmable valves who would benefit from osseointegrated hearing devices (OIHDs) represent a unique population. The aim of this study was to evaluate the magnetic field strengths of 4 OIHDs and their interactions with 5 programmable VP shunt valves. METHODS Magnetic field strength was measured as a function of distance for each hearing device (Cochlear Baha 5, Cochlear Baha BP110, Oticon Ponto Plus Power, and Medtronic Sophono) in the following modes: inactive, active in quiet, and active in 60 decibels of background noise in the sound booth. The hearing devices were introduced to each shunt valve (Aesculap proGAV, Aesculap proGAV 2.0, Codman Hakim, Codman Certas, and Medtronic Strata II) also as a function of distance in these identical 3 settings. Each trial was repeated 5 times. Between each trial, the valves were assessed for a change in setting. Finally, using a skull model, the devices were introduced to each other in standard anatomical locations and the valves were assessed for a change in settings. RESULTS The maximum magnetic field strengths generated by the Cochlear Baha 5, BP110, and Oticon OIHDs were 1.1, 36.2, and 48.7 gauss (G), respectively. The maximum strength generated by the Sophono device was > 800 G. The magnetic field strength of the hearing devices decreased markedly with increasing distance from the device. The strength of the Sophono's magnetic attachment decreased to 34.8 G at 5 mm. The Codman Hakim, Codman Certas, and Medtronic Strata II valve settings changed when rotating the valves next to the Sophono abutment. No other changes in valve settings occurred in the distance or anatomical models for any other trials. CONCLUSIONS This is the first study evaluating the interaction between OIHDs and programmable VP shunt valves. The findings suggest that it is safe to use these devices together without having to switch to a nonprogrammable valve or move the shunt valve to a more distant location. Still, care should be taken if the Sophono device is used to ensure that the valve is ≥ 5 mm away from the magnetic attachment.

  5. Quality measures for the management of hydrocephalus: concepts, simulations, and preliminary field-testing.

    PubMed

    Barton, Spencer E; Campbell, Jeffrey W; Piatt, Joseph H

    2013-04-01

    The authors define and examine the properties of 2 new, practice-based quality measures for the management of hydrocephalus. The Surgical Activity Rate (SAR) is defined as the number of definitive operations for the treatment of hydrocephalus performed in a neurosurgical practice over the course of a year, divided by the number of patients with hydrocephalus seen in follow-up during that year. The Revision Quotient (RQ) is defined as the number of definitive revision operations performed in a neurosurgical practice in the course of a year, divided by the number of definitive initial operations during that year for patients with newly diagnosed hydrocephalus. Using published actuarial shunt survival data, the authors conducted Monte Carlo simulations of a pediatric neurosurgical practice to illustrate the properties and interpretations of the SAR and RQ. They used data from the Kids' Inpatient Database (KID) for 2009 to calculate RQs for hospitals accounting for more than 10 admissions coded for initial CSF shunt insertions. During the initial growth phase of a simulated neurosurgical practice, the SAR approached its steady-state value much earlier than the RQ. Both measures were sensitive to doubling or halving of monthly failure rates. In the 2009 KID, 117 hospitals reported more than 10 initial shunt insertions. The weighted mean (± standard deviation) RQ for these hospitals was 1.79 ± 0.69. Among hospitals performing 50 or more initial shunt insertions, the RQ ranged between 0.71 and 3.65. The SAR and RQ have attractive qualitative features as practice-based quality measures. The RQ, at least, exhibits clinically meaningful interhospital variation as applied to CSF shunt surgery. The SAR and RQ merit prospective field-testing as measures of quality in the management of childhood hydrocephalus.

  6. Clinical features of congenital portosystemic shunt in children.

    PubMed

    Kim, Myung Jin; Ko, Jae Sung; Seo, Jeong Kee; Yang, Hye Ran; Chang, Ju Young; Kim, Gi Beom; Cheon, Jung-Eun; Kim, Woo Sun

    2012-02-01

    Clinical features, images, complications, treatments, and prognosis of 10 children with congenital portosystemic shunt (CPSS) were reviewed. Nine children were diagnosed with intrahepatic shunts while one presented with extrahepatic shunt. CPSS was detected by prenatal ultrasonography in four infants. Three infants presented with galactosemia without an enzyme deficiency. Two children presented with mental retardation and attention deficit hyperactivity disorder. Pulmonary hypertension developed in two patients. Spontaneous closure occurred in four infants with intrahepatic shunts including patent ductus venosus. The shunts were closed using transcatheter embolizations in four patients with intrahepatic shunts. Intrahepatic shunts may close spontaneously. Transcatheter embolization is effective for the treatment of symptomatic intrahepatic shunts.

  7. The Barrow Innovation Center Case Series: A novel 3D-printed retractor for use with electromagnetic neuronavigation systems.

    PubMed

    Bohl, Michael A; Xu, David S; Cavallo, Claudio; Paisan, Gabriella M; Smith, Kris A; Nakaji, Peter

    2018-06-01

    The Barrow Innovation Center consists of an educational program that promotes interdisciplinary collaboration among neurosurgery, legal, and engineering professionals to foster the development of new medical devices. This report describes a common issue faced during the placement of ventricular shunts for the treatment of hydrocephalus, and the solution to this problem that was developed through the Barrow Innovation Center. Neurosurgery residents involved in the Barrow Innovation Center presented the problem of ferromagnetic retractors interfering with pinless image-guidance systems at a monthly meeting. Potential solutions were openly discussed by an interdisciplinary committee of neurosurgeons, patent lawyers, and biomedical engineers. The committee decided to pursue development of a novel self-retaining retractor made of non-ferromagnetic material as a solution to the problem. Each retractor design was tested in the cadaver laboratory for size and functionality. A final design was chosen and used in a surgical case requiring ventriculoperitoneal shunt placement. The new retractor successfully retracted the scalp without interfering with the electromagnetic image-guidance system. Through the interdisciplinary Barrow Innovation Center program, a newly designed, 3-dimensional-printed skin and soft tissue retractor was created, along with an innovative universal shunt retainer. Through this integrated program dedicated to surgical innovation (i.e., the Barrow Innovation Center), the process of developing and implementing new technology at our institution has been streamlined, creating a culture of innovation within the neurosurgery training program. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. A prospective study of basal insulin concentrations in dogs with congenital portosystemic shunts.

    PubMed

    Collings, A J; Gow, A G; Marques, A; Yool, D; Furneaux, R; Mellanby, R; Watson, P J

    2012-04-01

    Hypoglycaemia is a common cause of morbidity in dogs with congenital portosystemic shunts but the aetiology is unknown. The hypothesis of this study was that dogs with congenital portosystemic shunts would have significantly higher insulin concentrations than dogs without congenital portosystemic shunts. The main objective of the study was to compare peripheral glucose and insulin concentrations between dogs with congenital portosystemic shunts and dogs without congenital portosystemic shunts. Peripheral serum insulin and plasma glucose concentrations were measured in dogs with congenital portosystemic shunts and without congenital portosystemic shunts and compared both between groups as well as to reference intervals derived from healthy dogs. Congenital portosystemic shunts were diagnosed in 41 dogs. Forty-eight dogs hospitalised with other conditions acted as controls. Serum insulin concentrations were mildly elevated (Ä40 μU/mL) in seven dogs and were markedly elevated in two dogs with congenital portosystemic shunts, yet mild hypoglycaemia (3·3 mmol/L) was detected in only one of these dogs. Four dogs with congenital portosystemic shunts showed fasting hypoglycaemia, yet insulin concentrations were within or below the reference interval in three. There was no difference between the median insulin concentration of dogs with congenital portosystemic shunts and without congenital portosystemic shunts. Hyperinsulinaemia is infrequently observed in dogs with congenital portosystemic shunts. The aetiology of hypoglycaemia in dogs with congenital portosystemic shunts merits further investigation. © 2012 British Small Animal Veterinary Association.

  9. Failure Engineering Study and Accelerated Stress Test Results for the Mars Global Surveyor Spacecraft's Power Shunt Assemblies

    NASA Technical Reports Server (NTRS)

    Gibbel, Mark; Larson, Timothy

    2000-01-01

    An Engineering-of-Failure approach to designing and executing an accelerated product qualification test was performed to support a risk assessment of a "work-around" necessitated by an on-orbit failure of another piece of hardware on the Mars Global Surveyor spacecraft. The proposed work-around involved exceeding the previous qualification experience both in terms of extreme cold exposure level and in terms of demonstrated low cycle fatigue life for the power shunt assemblies. An analysis was performed to identify potential failure sites, modes and associated failure mechanisms consistent with the new use conditions. A test was then designed and executed which accelerated the failure mechanisms identified by analysis. Verification of the resulting failure mechanism concluded the effort.

  10. Ventriculoperitoneal shunt - discharge

    MedlinePlus

    ... ventriculoperitoneal - discharge; VP shunt - discharge; Shunt revision - discharge; Hydrocephalus shunt placement - discharge ... Your child has hydrocephalus and needed a shunt placed to drain excess fluid and relieve pressure in the brain. This buildup of brain ...

  11. Correlates of local cerebral blood flow (CBF) in normal pressure hydrocephalus patients before and after shunting--A retrospective analysis of [(15)O]H(2)O PET-CBF studies in 65 patients.

    PubMed

    Klinge, Petra M; Brooks, David J; Samii, Amir; Weckesser, Eva; van den Hoff, Jörg; Fricke, Harald; Brinker, Thomas; Knapp, Wolfram H; Berding, Georg

    2008-04-01

    Findings in local cerebral blood flow (rCBF) in Normal pressure hydrocephalus (NPH) have always been challenged by the variable and inconsistent relation to clinical symptoms before and after shunt treatment. [(15)O]H(2)O PET data from a consecutive cohort of 65 idiopathic NPH patients were retrospectively analyzed questioning whether the functional status before and after shunt treatment might correlate with local blood flow. Using statistical parametric mapping (SPM99, Wellcome Department of Cognitive Neurology, London), the [(15)O]H(2)O uptake was correlated with the preoperative clinical scores, graded according to a modified Stein and Langfitt score. Furthermore, differences in the uptake in the pre-and post-shunt treatment study after seven to 10 days in patients with and without clinical improvement were studied. A higher clinical score significantly correlated with a reduced tracer uptake in mesial frontal (k=1,239 voxel, Z=4.41) and anterior temporal (k=469, Z=4.07) areas. In the mesial frontal areas, tracer uptake showed significant reciprocal changes in the clinically improved vs. the unimproved patients. Matched with the existing literature, the regional blood flow alterations are suggested relevant to the NPH syndrome and to post-treatment functional changes. The present rCBF findings warrant prospective studies on the accuracy of neuroimaging studies as they may provide a more specific insight into disease mechanisms.

  12. Congenital hypothyroidism in a kitten resulting in decreased IGF-I concentration and abnormal liver function tests.

    PubMed

    Quante, Saskia; Fracassi, Federico; Gorgas, Daniela; Kircher, Patrick R; Boretti, Felicitas S; Ohlerth, Stefanie; Reusch, Claudia E

    2010-06-01

    A 7-month-old male kitten was presented with chronic constipation and retarded growth. Clinical examination revealed disproportional dwarfism with mild skeletal abnormalities and a palpable thyroid gland. The presumptive diagnosis of congenital hypothyroidism was confirmed by low serum total thyroxine (tT(4)) concentration prior to and after the administration of thyroid stimulation hormone (TSH), increased endogenous TSH concentration and abnormal thyroid scintigraphic scan. The kitten had abnormal liver function tests and decreased insulin-like growth factor 1 (IGF-1) concentration, both of which returned to normal in correspondence with an improvement of the clinical signs after 6 weeks of thyroxine therapy. Congenital hypothyroidism is a rare disease that may present with considerable variation in clinical manifestation. In cases in which clinical signs are ambiguous, disorders such as portosystemic shunt and hyposomatotropism have to be taken into account as differential diagnosis. As hypothyroidism may be associated with abnormal liver function tests and low IGF-1 concentrations, test results have to be interpreted carefully. Copyright 2010 ISFM and AAFP. Published by Elsevier Ltd. All rights reserved.

  13. Programmable valve shunts: are they really better?

    PubMed

    Kataria, Rashim; Kumar, Vimal; Mehta, Veer Singh

    2012-01-01

    Programmable valve shunts allows selection of opening pressure of shunt valve. In the presented article, a unique complication pertaining to programmable shunts has been discussed. A 5-year-old boy who had tectal plate low grade glioma with obstructive hydrocephalus was managed with Codman programmable ventriculoperitoneal shunt. There was a spontaneous change in the opening pressure of the shunt valve leading to shunt malfunction. Routinely used household appliances produce a magnetic field strong enough to cause change in the setting of shunt valve pressure and may lead to valve malfunction. Other causes of programmable valve malfunction also discussed.

  14. Cerebrospinal fluid dynamics study in communicating hydrocephalus.

    PubMed

    Ramesh, Vengalathur Ganesan; Narasimhan, Vidhya; Balasubramanian, Chandramouli

    2017-01-01

    Communicating hydrocephalus often poses a challenge in diagnosis and management decisions. The objective of this study is to measure the opening pressure (P o ), pressure volume index (PVI), and cerebrospinal fluid outflow resistance (R out ), in patients with communicating hydrocephalus using bolus lumbar injection method and to evaluate its diagnostic and prognostic value. The study was conducted in 50 patients with communicating hydrocephalus, including normal pressure hydrocephalus (NPH) (19), post-meningitic hydrocephalus (23) and post-traumatic hydrocephalus (8). An improvised bolus lumbar injection method [the Madras Institute of Neurology (MIN) method] was used. In the NPH Group, the CSF dynamics studies correlated well with the clinico-radiological classification. The prediction of shunt responsiveness by CSF dynamics studies correlated with good outcome in 87.5%. In the post-meningitic hydrocephalus group, the value of CSF dynamics studies in predicting patients needing shunt was 89.5%. The CSF dynamics studies detected patients who needed shunt earlier than clinical or radiological indications. In the post-traumatic hydrocephalus group, 62.5% of patients improved with the treatment based on CSF dynamics studies. The improvised bolus lumbar injection method (MIN method) is a very simple test with fairly reliable and reproducible results. Study of CSF dynamics is a valuable tool in communicating hydrocephalus for confirmation of diagnosis and predicting shunt responsiveness. This is the first time that the value of CSF dynamics has been studied in patients with post-meningitic hydrocephalus. It was also useful for early selection of cases for shunting and for identifying patients with atrophic ventriculomegaly, thereby avoiding unnecessary shunt.

  15. Cerebrospinal fluid dynamics study in communicating hydrocephalus

    PubMed Central

    Ramesh, Vengalathur Ganesan; Narasimhan, Vidhya; Balasubramanian, Chandramouli

    2017-01-01

    Context: Communicating hydrocephalus often poses a challenge in diagnosis and management decisions. Aims: The objective of this study is to measure the opening pressure (Po), pressure volume index (PVI), and cerebrospinal fluid outflow resistance (Rout), in patients with communicating hydrocephalus using bolus lumbar injection method and to evaluate its diagnostic and prognostic value. Materials and Methods: The study was conducted in 50 patients with communicating hydrocephalus, including normal pressure hydrocephalus (NPH) (19), post-meningitic hydrocephalus (23) and post-traumatic hydrocephalus (8). An improvised bolus lumbar injection method [the Madras Institute of Neurology (MIN) method] was used. Results: In the NPH Group, the CSF dynamics studies correlated well with the clinico-radiological classification. The prediction of shunt responsiveness by CSF dynamics studies correlated with good outcome in 87.5%. In the post-meningitic hydrocephalus group, the value of CSF dynamics studies in predicting patients needing shunt was 89.5%. The CSF dynamics studies detected patients who needed shunt earlier than clinical or radiological indications. In the post-traumatic hydrocephalus group, 62.5% of patients improved with the treatment based on CSF dynamics studies. Conclusions: The improvised bolus lumbar injection method (MIN method) is a very simple test with fairly reliable and reproducible results. Study of CSF dynamics is a valuable tool in communicating hydrocephalus for confirmation of diagnosis and predicting shunt responsiveness. This is the first time that the value of CSF dynamics has been studied in patients with post-meningitic hydrocephalus. It was also useful for early selection of cases for shunting and for identifying patients with atrophic ventriculomegaly, thereby avoiding unnecessary shunt. PMID:28484522

  16. Mathematical Modeling of the Pituitary–Thyroid Feedback Loop: Role of a TSH-T3-Shunt and Sensitivity Analysis

    PubMed Central

    Berberich, Julian; Dietrich, Johannes W.; Hoermann, Rudolf; Müller, Matthias A.

    2018-01-01

    Despite significant progress in assay technology, diagnosis of functional thyroid disorders may still be a challenge, as illustrated by the vague upper limit of the reference range for serum thyrotropin (TSH). Diagnostical problems also apply to subjects affected by syndrome T, i.e., those 10% of hypothyroid patients who continue to suffer from poor quality of life despite normal TSH concentrations under substitution therapy with levothyroxine (L-T4). In this paper, we extend a mathematical model of the pituitary–thyroid feedback loop in order to improve the understanding of thyroid hormone homeostasis. In particular, we incorporate a TSH-T3-shunt inside the thyroid, whose existence has recently been demonstrated in several clinical studies. The resulting extended model shows good accordance with various clinical observations, such as a circadian rhythm in free peripheral triiodothyronine (FT3). Furthermore, we perform a sensitivity analysis of the derived model, revealing the dependence of TSH and hormone concentrations on different system parameters. The results have implications for clinical interpretation of thyroid tests, e.g., in the differential diagnosis of subclinical hypothyroidism. PMID:29619006

  17. Mathematical Modeling of the Pituitary-Thyroid Feedback Loop: Role of a TSH-T3-Shunt and Sensitivity Analysis.

    PubMed

    Berberich, Julian; Dietrich, Johannes W; Hoermann, Rudolf; Müller, Matthias A

    2018-01-01

    Despite significant progress in assay technology, diagnosis of functional thyroid disorders may still be a challenge, as illustrated by the vague upper limit of the reference range for serum thyrotropin ( TSH ). Diagnostical problems also apply to subjects affected by syndrome T, i.e., those 10% of hypothyroid patients who continue to suffer from poor quality of life despite normal TSH concentrations under substitution therapy with levothyroxine ( L - T 4 ). In this paper, we extend a mathematical model of the pituitary-thyroid feedback loop in order to improve the understanding of thyroid hormone homeostasis. In particular, we incorporate a TSH - T 3 -shunt inside the thyroid, whose existence has recently been demonstrated in several clinical studies. The resulting extended model shows good accordance with various clinical observations, such as a circadian rhythm in free peripheral triiodothyronine ( FT 3 ). Furthermore, we perform a sensitivity analysis of the derived model, revealing the dependence of TSH and hormone concentrations on different system parameters. The results have implications for clinical interpretation of thyroid tests, e.g., in the differential diagnosis of subclinical hypothyroidism.

  18. Morphology of congenital portosystemic shunts emanating from the left gastric vein in dogs and cats.

    PubMed

    White, R N; Parry, A T

    2013-09-01

    To describe the anatomy of congenital portosystemic shunts emanating from the left gastric vein in dogs and cats. A retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. Forty-six dogs and 27 cats met the inclusion criteria of a congenital portosystemic shunt emanating from the left gastric vein. Of the 46 dogs, 28 (61%) had a shunt that entered the left phrenic vein, 10 (22%) had a shunt that entered the post hepatic caudal vena cava and in 8 (17%) the shunt entered the azygos vein. Of the 27 cats, 19 (70%) had a shunt that entered the left phrenic vein and 8 (30%) had a shunt that entered the post hepatic caudal vena cava. The systemic vein into which the shunt entered was consistent showing three common presentations: left gastro-phrenic, left gastro-caval and left gastro-azygos. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2013 British Small Animal Veterinary Association.

  19. Functional morphology and patterns of blood flow in the heart of Python regius.

    PubMed

    Starck, J Matthias

    2009-06-01

    Brightness-modulated ultrasonography, continuous-wave Doppler, and pulsed-wave Doppler-echocardiography were used to analyze the functional morphology of the undisturbed heart of ball pythons. In particular, the action of the muscular ridge and the atrio-ventricular valves are key features to understand how patterns of blood flow emerge from structures directing blood into the various chambers of the heart. A step-by-step image analysis of echocardiographs shows that during ventricular diastole, the atrio-ventricular valves block the interventricular canals so that blood from the right atrium first fills the cavum venosum, and blood from the left atrium fills the cavum arteriosum. During diastole, blood from the cavum venosum crosses the muscular ridge into the cavum pulmonale. During middle to late systole the muscular ridge closes, thus prohibiting further blood flow into the cavum pulmonale. At the same time, the atrio-ventricular valves open the interventricular canal and allow blood from the cavum arteriosum to flow into the cavum venosum. In the late phase of ventricular systole, all blood from the cavum pulmonale is pressed into the pulmonary trunk; all blood from the cavum venosum is pressed into both aortas. Quantitative measures of blood flow volume showed that resting snakes bypass the pulmonary circulation and shunt about twice the blood volume into the systemic circulation as into the pulmonary circulation. When digesting, the oxygen demand of snakes increased tremendously. This is associated with shunting more blood into the pulmonary circulation. The results of this study allow the presentation of a detailed functional model of the python heart. They are also the basis for a functional hypothesis of how shunting is achieved. Further, it was shown that shunting is an active regulation process in response to changing demands of the organism (here, oxygen demand). Finally, the results of this study support earlier reports about a dual pressure circulation in Python regius.

  20. PubMed Central

    Caron, C.; Luneau, C.; Gervais, M. H.; Plante, G. E.; Sanchez, G.; Blain, G.

    1979-01-01

    In patients with cerebrospinal fluid internal shunts, immune complex glomerulonephritis sometimes develops. Of two new cases the first was classic, while the second was in an adult who had had a ventriculoatril shunt for 8 years; furthermore, the patient had acute renal failure and is the first to have been reported to have Peptococcus septicemia. Shunt glomerulonephritis is characterized by the following: (a) its occurrence following, most often, Staphylococcus albus infection in a patient who usually has a ventriculoatrial shunt; (b) transitory improvement of the symptoms by antibiotherapy only; and (c) full recovery if the prosthesis is removed. Laboratory studies show a low serum concentration of the C3 component of complement, the presence of cryoglobulins and a positive rheumatoid factor test. These abnormalities are reversible with removal of the prosthesis. Optical microscopy of a renal biopsy specimen in the two cases showed cellular proliferation of the glomerular tuft, electron microscopy demonstrated subepithelial deposits and immunofluorescent studies revealed intramembranous and intramesangial immune complexes. These features are similar to those observed in experimental nephritis induced in animals by foreign protein. Images FIG. 3 FIG. 4 FIG. 5 FIG. 6 FIG. 7 PMID:436034

  1. Patent ductus arteriosus in an adult cat with pulmonary hypertension and right-sided congestive heart failure: hemodynamic evaluation and clinical outcome following ductal closure.

    PubMed

    Novo-Matos, José; Hurter, Karin; Bektas, Rima; Grest, Paula; Glaus, Tony

    2014-09-01

    Right-sided congestive heart failure (CHF) developed secondary to severe pulmonary hypertension (PH) in an 8-year-old cat with a left-to-right shunting patent ductus arteriosus (PDA). Vascular reactivity was tested prior to shunt ligation by treatment with oxygen and sildenafil. This treatment was associated with a significant decrease in pulmonary artery pressure as assessed by echocardiography. Subsequently surgical shunt ligation was planned. During thoracotomy, digital occlusion of the PDA was performed for 10 min with simultaneous catheter measurement of right ventricular pressure, which did not increase. Permanent shunt ligation resulted in a complete and sustained clinical recovery. A lung biopsy sample obtained during thoracotomy demonstrated histopathological arterial changes typical of PH. Cats can develop clinically severe PH and right-sided CHF secondary to a left-to-right PDA even at an advanced age. Assuming there is evidence of pulmonary reactivity, PDA occlusion might be tolerated and can potentially produce long-term clinical benefits. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. 18 CFR 367.3950 - Account 395, Laboratory equipment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... bottles for meter prover testing. (33) Standard cell, reactance, resistor, and shunt. (34) Stills. (35.... (45) Other items of equipment for testing gas, fuel, flue gas, water, residuals, and other similar...

  3. A comparison of micropore membrane inlet mass spectrometry-derived pulmonary shunt measurement with Riley shunt in a porcine model.

    PubMed

    Duenges, Bastian; Vogt, Andreas; Bodenstein, Marc; Wang, Hemei; Böhme, Stefan; Röhrig, Bernd; Baumgardner, James E; Markstaller, Klaus

    2009-12-01

    The multiple inert gas elimination technique was developed to measure shunt and the ratio of alveolar ventilation to simultaneous alveolar capillary blood flow in any part of the lung (V(A)'/Q') distributions. Micropore membrane inlet mass spectrometry (MMIMS), instead of gas chromatography, has been introduced for inert gas measurement and shunt determination in a rabbit lung model. However, agreement with a frequently used and accepted method for quantifying deficits in arterial oxygenation has not been established. We compared MMIMS-derived shunt (M-S) as a fraction of total cardiac output (CO) with Riley shunt (R-S) derived from the R-S formula in a porcine lung injury model. To allow a broad variance of atelectasis and therefore shunt fraction, 8 sham animals did not receive lavage, and 8 animals were treated by lung lavages with 30 mL/kg warmed lactated Ringer's solution as follows: 2 animals were lavaged once, 5 animals twice, and 1 animal 3 times. Variables were recorded at baseline and twice after induction of lung injury (T1 and T2). Retention data of sulfur hexafluoride, krypton, desflurane, enflurane, diethyl ether, and acetone were analyzed by MMIMS, and M-S was derived using a known algorithm for the multiple inert gas elimination technique. Standard formulas were used for the calculation of R-S. Forty-four pairs of M-S and R-S were recorded. M-S ranged from 0.1% to 35.4% and R-S from 3.7% to 62.1%. M-S showed a correlation with R-S described by linear regression: M-S = -4.26 + 0.59 x R-S (r(2) = 0.83). M-S was on average lower than R-S (mean = -15.0% CO, sd = 6.5% CO, and median = -15.1), with lower and upper limits of agreement of -28.0% and -2.0%, respectively. The lower and upper limits of the 95% confidence intervals were -17.0 and -13.1 (P < 0.001, Student's t-test). Shunt derived from MMIMS inert gas retention data correlated well with R-S during breathing of oxygen. Shunt as derived by MMIMS was generally less than R-S.

  4. Superconducting fault current-limiter with variable shunt impedance

    DOEpatents

    Llambes, Juan Carlos H; Xiong, Xuming

    2013-11-19

    A superconducting fault current-limiter is provided, including a superconducting element configured to resistively or inductively limit a fault current, and one or more variable-impedance shunts electrically coupled in parallel with the superconducting element. The variable-impedance shunt(s) is configured to present a first impedance during a superconducting state of the superconducting element and a second impedance during a normal resistive state of the superconducting element. The superconducting element transitions from the superconducting state to the normal resistive state responsive to the fault current, and responsive thereto, the variable-impedance shunt(s) transitions from the first to the second impedance. The second impedance of the variable-impedance shunt(s) is a lower impedance than the first impedance, which facilitates current flow through the variable-impedance shunt(s) during a recovery transition of the superconducting element from the normal resistive state to the superconducting state, and thus, facilitates recovery of the superconducting element under load.

  5. Phosphorylated tau/amyloid beta 1-42 ratio in ventricular cerebrospinal fluid reflects outcome in idiopathic normal pressure hydrocephalus

    PubMed Central

    2012-01-01

    Background Idiopathic normal pressure hydrocephalus (iNPH) is a potentially reversible cause of dementia and gait disturbance that is typically treated by operative placement of a ventriculoperitoneal shunt. The outcome from shunting is variable, and some evidence suggests that the presence of comorbid Alzheimer's disease (AD) may impact shunt outcome. Evidence also suggests that AD biomarkers in cerebrospinal fluid (CSF) may predict the presence of AD. The aim of this study was to investigate the relationship between the phosphorylated tau/amyloid beta 1-42 (ptau/Aβ1-42) ratio in ventricular CSF and shunt outcome in patients with iNPH. Methods We conducted a prospective trial with a cohort of 39 patients with suspected iNPH. Patients were clinically and psychometrically assessed prior to and approximately 4 months after ventriculoperitoneal shunting. Lumbar and ventricular CSF obtained intraoperatively, and tissue from intraoperative cortical biopsies were analyzed for AD biomarkers. Outcome measures included performance on clinical symptom scales, supplementary gait measures, and standard psychometric tests. We investigated relationships between the ptau/Aβ1-42 ratio in ventricular CSF and cortical AD pathology, initial clinical features, shunt outcome, and lumbar CSF ptau/Aβ1-42 ratios in the patients in our cohort. Results We found that high ptau/Aβ1-42 ratios in ventricular CSF correlated with the presence of cortical AD pathology. At baseline, iNPH patients with ratio values most suggestive of AD presented with better gait performance but poorer cognitive performance. Patients with high ptau/Aβ1-42 ratios also showed a less robust response to shunting on both gait and cognitive measures. Finally, in a subset of 18 patients who also underwent lumbar puncture, ventricular CSF ratios were significantly correlated with lumbar CSF ratios. Conclusions Levels of AD biomarkers in CSF correlate with the presence of cortical AD pathology and predict aspects of clinical presentation in iNPH. Moreover, preliminary evidence suggests that CSF biomarkers of AD may prove useful for stratifying shunt prognosis in patients being evaluated and treated for this condition. PMID:22444461

  6. Harmonic Resonance in Power Transmission Systems due to the Addition of Shunt Capacitors

    NASA Astrophysics Data System (ADS)

    Patil, Hardik U.

    Shunt capacitors are often added in transmission networks at suitable locations to improve the voltage profile. In this thesis, the transmission system in Arizona is considered as a test bed. Many shunt capacitors already exist in the Arizona transmission system and more are planned to be added. Addition of these shunt capacitors may create resonance conditions in response to harmonic voltages and currents. Such resonance, if it occurs, may create problematic issues in the system. It is main objective of this thesis to identify potential problematic effects that could occur after placing new shunt capacitors at selected buses in the Arizona network. Part of the objective is to create a systematic plan for avoidance of resonance issues. For this study, a method of capacitance scan is proposed. The bus admittance matrix is used as a model of the networked transmission system. The calculations on the admittance matrix were done using Matlab. The test bed is the actual transmission system in Arizona; however, for proprietary reasons, bus names are masked in the thesis copy intended for the public domain. The admittance matrix was obtained from data using the PowerWorld Simulator after equivalencing the 2016 summer peak load (planning case). The full Western Electricity Coordinating Council (WECC) system data were used. The equivalencing procedure retains only the Arizona portion of the WECC. The capacitor scan results for single capacitor placement and multiple capacitor placement cases are presented. Problematic cases are identified in the form of 'forbidden response. The harmonic voltage impact of known sources of harmonics, mainly large scale HVDC sources, is also presented. Specific key results for the study indicated include: (1) The forbidden zones obtained as per the IEEE 519 standard indicates the bus 10 to be the most problematic bus. (2) The forbidden zones also indicate that switching values for the switched shunt capacitor (if used) at bus 3 should be should be considered carefully to avoid resonance condition from existing. (3) The highest sensitivity of 0.0033 per unit for HVDC sources of harmonics was observed at bus 7 when all the HVDC sources were active at the same time.

  7. The clinical anatomy of congenital portosystemic venous shunts.

    PubMed

    Stringer, Mark D

    2008-03-01

    Congenital portosystemic venous shunts are rare. Their gross anatomy has not been well defined. Four different varieties of congenital portosystemic venous shunts are described in six children seen during a 10-year period, focusing on the anatomy of the shunt as determined by imaging studies and surgery. A detailed review of the literature indicates that congenital portosystemic venous shunts are best classified as: extrahepatic or intrahepatic. Extrahepatic shunts may be further subdivided into portocaval shunts (type 1 end-to-side and type 2 side-to-side) and others. Intrahepatic shunts are due to an abnormal intrahepatic connection between the portal vein and hepatic vein/inferior vena cava or a persistent patent ductus venosus. Additional congenital anomalies, particularly cardiac malformations, may be associated with any type. Some congenital intrahepatic portosystemic venous shunts close spontaneously in infancy; all other congenital portosystemic venous shunts tend to remain patent. To a variable extent, depending largely on the volume and duration of the shunt, affected individuals are at risk of developing hepatic encephalopathy and/or an intrahepatic tumor. The key to understanding the pathogenesis of these shunts lies in the normal developmental mechanisms underlying the formation of the portal vein and inferior vena cava in the embryo. Copyright 2008 Wiley-Liss, Inc.

  8. The effectiveness of using the calculated braking current for longitudinal differential protection of 110 - 750 kV shunt reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vdovin, S. A.; Shalimov, A. S.

    2013-05-15

    The use of the function of effective current braking of the longitudinal differential protection of shunt reactors to offset current surges, which enables the sensitivity of differential protection to be increased when there are short circuits with low damage currents, is considered. It is shown that the use of the calculated braking characteristic enables the reliability of offset protection from transients to be increased when the reactor is connected, which is accompanied by the flow of asymmetric currents containing an aperiodic component.

  9. Cardiovascular function, compliance, and connective tissue remodeling in the turtle, Trachemys scripta, following thermal acclimation

    PubMed Central

    Keen, Adam N.; Crossley, Dane A.

    2016-01-01

    Low temperature directly alters cardiovascular physiology in freshwater turtles, causing bradycardia, arterial hypotension, and a reduction in systemic blood pressure. At the same time, blood viscosity and systemic resistance increase, as does sensitivity to cardiac preload (e.g., via the Frank-Starling response). However, the long-term effects of these seasonal responses on the cardiovascular system are unclear. We acclimated red-eared slider turtles to a control temperature (25°C) or to chronic cold (5°C). To differentiate the direct effects of temperature from a cold-induced remodeling response, all measurements were conducted at the control temperature (25°C). In anesthetized turtles, cold acclimation reduced systemic resistance by 1.8-fold and increased systemic blood flow by 1.4-fold, resulting in a 2.3-fold higher right to left (R-L; net systemic) cardiac shunt flow and a 1.8-fold greater shunt fraction. Following a volume load by bolus injection of saline (calculated to increase stroke volume by 5-fold, ∼2.2% of total blood volume), systemic resistance was reduced while pulmonary blood flow and systemic pressure increased. An increased systemic blood flow meant the R-L cardiac shunt was further pronounced. In the isolated ventricle, passive stiffness was increased following cold acclimation with 4.2-fold greater collagen deposition in the myocardium. Histological sections of the major outflow arteries revealed a 1.4-fold higher elastin content in cold-acclimated animals. These results suggest that cold acclimation alters cardiac shunting patterns with an increased R-L shunt flow, achieved through reducing systemic resistance and increasing systemic blood flow. Furthermore, our data suggests that cold-induced cardiac remodeling may reduce the stress of high cardiac preload by increasing compliance of the vasculature and decreasing compliance of the ventricle. Together, these responses could compensate for reduced systolic function at low temperatures in the slider turtle. PMID:27101300

  10. Bile acid malabsorption after intestinal bypass surgery for obesity. A comparison between jejunoileal shunt and biliointestinal bypass.

    PubMed

    Nyhlin, H; Brydon, G; Danielsson, A; Eriksson, F

    1990-01-01

    Seventeen patients were operated on with intestinal shunts for morbid obesity, in eight a biliointestinal bypass (BI) was constructed and in the rest a conventional jejunoileal (JI)-shunt. The reduction in weight was similar in both groups, and so was malabsorption of fat, but the BI-group had significantly less bowel motions with less watery diarrhoea. Bile acid malabsorption was measured both chemically by estimating the total amount of faecal bile acids excreted, as well as indirectly by using a 75Se-labelled synthetic bile acid (SeHCAT). Both techniques revealed a substantial loss of bile acid after both types of operation, but patients with BI bypass surgery had significantly lower elimination time of the bile acid than those with JI-shunts. There was a significant negative correlation between SeHCAT retention and total faecal bile acids. However, some patients with low SeHCAT retention had normal or even reduced output of faecal bile acids. Estimation of faecal bile acids may display false negative results when the bile acid pool is decreased. The SeHCAT-test seems to be a better technique for measuring bile acid losses. The study suggests that BI bypass surgery for obesity seems to be advantageous over the JI shunt in reducing the postoperative loss of bile acids and choleretic diarrhoea, without influencing the weight loss.

  11. Device physics of Cu(In,Ga)Se2 solar cells for long-term operation

    NASA Astrophysics Data System (ADS)

    Nishinaga, J.; Shibata, H.

    2017-02-01

    The degradation mechanism of Cu(In,Ga)Se2 (CIGS) solar cells on exposure to air has been investigated. Exposure to air at room temperature slightly reduces the conversion efficiency of CIGS solar cells, and the conversion efficiency decreases significantly under damp heat testing at 85 °C and 85% relative humidity due to low shunt resistance. On the other hand, shunt resistance increases after dry nitrogen heating. Therefore, oxygen and humidity should degenerate the solar cell performance. The low shunt resistance and conversion efficiency are completely recovered after removing the side edges of the CIGS solar cells by mechanical scribing. These results suggest that low-resistive layers are formed on the sidewalls of the solar cells during damp heat testing. The low-resistive layers on the sidewalls are identified to be molybdenum oxides and sodium molybdate by Auger electron spectroscopy. After etching the oxides on the sidewalls by alkaline solution, the saturation current density and ideality factor are confirmed to be improved. These results suggest that metal oxides on the sidewalls of CIGS solar cells may act as recombination centers.

  12. Primary ventriculoperitoneal shunting outcomes: a multicentre clinical audit for shunt infection and its risk factors.

    PubMed

    Woo, P Ym; Wong, H T; Pu, J Ks; Wong, W K; Wong, L Yw; Lee, M Wy; Yam, K Y; Lui, W M; Poon, W S

    2016-10-01

    To determine the frequency of primary ventriculoperitoneal shunt infection among patients treated at neurosurgical centres of the Hospital Authority and to identify underlying risk factors. This multicentre historical cohort study included consecutive patients who underwent primary ventriculoperitoneal shunting at a Hospital Authority neurosurgery centre from 1 January 2009 to 31 December 2011. The primary endpoint was shunt infection, defined as: (1) the presence of cerebrospinal fluid or shunt hardware culture that yielded the pathogenic micro-organism with associated compatible symptoms and signs of central nervous system infection or shunt malfunction; or (2) surgical incision site infection requiring shunt reinsertion (even in the absence of positive culture); or (3) intraperitoneal pseudocyst formation (even in the absence of positive culture). Secondary endpoints were shunt malfunction, defined as unsatisfactory cerebrospinal fluid drainage that required shunt reinsertion, and 30-day mortality. A primary ventriculoperitoneal shunt was inserted in 538 patients during the study period. The mean age of patients was 48 years (range, 13-88 years) with a male-to-female ratio of 1:1. Aneurysmal subarachnoid haemorrhage was the most common aetiology (n=169, 31%) followed by intracranial tumour (n=164, 30%), central nervous system infection (n=42, 8%), and traumatic brain injury (n=27, 5%). The mean operating time was 75 (standard deviation, 29) minutes. Shunt reinsertion and infection rates were 16% (n=87) and 7% (n=36), respectively. The most common cause for shunt reinsertion was malfunction followed by shunt infection. Independent predictors for shunt infection were: traumatic brain injury (adjusted odds ratio=6.2; 95% confidence interval, 2.3-16.8), emergency shunting (2.3; 1.0-5.1), and prophylactic vancomycin as the sole antibiotic (3.4; 1.1-11.0). The 30-day all-cause mortality was 6% and none were directly procedure-related. This is the first Hong Kong territory-wide review of infection in primary ventriculoperitoneal shunts. Although the ventriculoperitoneal shunt infection rate met international standards, there are areas of improvement such as vancomycin administration and the avoidance of scheduling the procedure as an emergency.

  13. Predicting ventriculoperitoneal shunt infection in children with hydrocephalus using artificial neural network.

    PubMed

    Habibi, Zohreh; Ertiaei, Abolhasan; Nikdad, Mohammad Sadegh; Mirmohseni, Atefeh Sadat; Afarideh, Mohsen; Heidari, Vahid; Saberi, Hooshang; Rezaei, Abdolreza Sheikh; Nejat, Farideh

    2016-11-01

    The relationships between shunt infection and predictive factors have not been previously investigated using Artificial Neural Network (ANN) model. The aim of this study was to develop an ANN model to predict shunt infection in a group of children with shunted hydrocephalus. Among more than 800 ventriculoperitoneal shunt procedures which had been performed between April 2000 and April 2011, 68 patients with shunt infection and 80 controls that fulfilled a set of meticulous inclusion/exclusion criteria were consecutively enrolled. Univariate analysis was performed for a long list of risk factors, and those with p value < 0.2 were used to create ANN and logistic regression (LR) models. Five variables including birth weight, age at the first shunting, shunt revision, prematurity, and myelomeningocele were significantly associated with shunt infection via univariate analysis, and two other variables (intraventricular hemorrhage and coincided infections) had a p value of less than 0.2. Using these seven input variables, ANN and LR models predicted shunt infection with an accuracy of 83.1 % (AUC; 91.98 %, 95 % CI) and 55.7 % (AUC; 76.5, 95 % CI), respectively. The contribution of the factors in the predictive performance of ANN in descending order was history of shunt revision, low birth weight (under 2000 g), history of prematurity, the age at the first shunt procedure, history of intraventricular hemorrhage, history of myelomeningocele, and coinfection. The findings show that artificial neural networks can predict shunt infection with a high level of accuracy in children with shunted hydrocephalus. Also, the contribution of different risk factors in the prediction of shunt infection can be determined using the trained network.

  14. Anatomy of hepatic arteriolo-portal venular shunts evaluated by 3D micro-CT imaging.

    PubMed

    Kline, Timothy L; Knudsen, Bruce E; Anderson, Jill L; Vercnocke, Andrew J; Jorgensen, Steven M; Ritman, Erik L

    2014-06-01

    The liver differs from other organs in that two vascular systems deliver its blood - the hepatic artery and the portal vein. However, how the two systems interact is not fully understood. We therefore studied the microvascular geometry of rat liver hepatic artery and portal vein injected with the contrast polymer Microfil(®). Intact isolated rat livers were imaged by micro-CT and anatomic evidence for hepatic arteriolo-portal venular shunts occurring between hepatic artery and portal vein branches was found. Simulations were performed to rule out the possibility of the observed shunts being artifacts resulting from image blurring. In addition, in the case of specimens where only the portal vein was injected, only the portal vein was opacified, whereas in hepatic artery injections, both the hepatic artery and portal vein were opacified. We conclude that mixing of the hepatic artery and portal vein blood can occur proximal to the sinusoidal level, and that the hepatic arteriolo-portal venular shunts may function as a one-way valve-like mechanism, allowing flow only from the hepatic artery to the portal vein (and not the other way around). © 2014 Mayo Foundation Journal of Anatomy © 2014 Anatomical Society.

  15. Simultaneous cranioplasty and subdural-peritoneal shunting for contralateral symptomatic subdural hygroma following decompressive craniectomy.

    PubMed

    Lin, Muh-Shi; Chen, Tzu-Hsuan; Kung, Woon-Man; Chen, Shuo-Tsung

    2015-01-01

    Contralateral subdural hygroma caused by decompressive craniectomy tends to combine with external cerebral herniation, causing neurological deficits. Nine patients who underwent one-stage, simultaneous cranioplasty and contralateral subdural-peritoneal shunting were included in this study. Clinical outcome was assessed by Glasgow Outcome Scale as well as Glasgow Coma Scale, muscle power scoring system, and complications. Postoperative computed tomography scans demonstrated completely resolved subdural hygroma and reversed midline shifts, indicating excellent outcome. Among these 9 patients, 4 patients (44%) had improved GOS following the proposed surgery. Four out of 4 patients with lethargy became alert and orientated following surgical intervention. Muscle strength improved significantly 5 months after surgery in 7 out of 7 patients with weakness. Two out of 9 patients presented with drowsiness due to hydrocephalus at an average time of 65 days after surgery. Double gradient shunting is useful to eliminate the respective hydrocephalus and contralateral subdural hygroma. The described surgical technique is effective in treating symptomatic contralateral subdural hygroma following decompressive craniectomy and is associated with an excellent structural and functional outcome. However, subdural-peritoneal shunting plus cranioplasty thoroughly resolves the subdural hygroma collection, which might deteriorate the cerebrospinal fluid circulation, leading to hydrocephalus.

  16. Decision tree analysis in subarachnoid hemorrhage: prediction of outcome parameters during the course of aneurysmal subarachnoid hemorrhage using decision tree analysis.

    PubMed

    Hostettler, Isabel Charlotte; Muroi, Carl; Richter, Johannes Konstantin; Schmid, Josef; Neidert, Marian Christoph; Seule, Martin; Boss, Oliver; Pangalu, Athina; Germans, Menno Robbert; Keller, Emanuela

    2018-01-19

    OBJECTIVE The aim of this study was to create prediction models for outcome parameters by decision tree analysis based on clinical and laboratory data in patients with aneurysmal subarachnoid hemorrhage (aSAH). METHODS The database consisted of clinical and laboratory parameters of 548 patients with aSAH who were admitted to the Neurocritical Care Unit, University Hospital Zurich. To examine the model performance, the cohort was randomly divided into a derivation cohort (60% [n = 329]; training data set) and a validation cohort (40% [n = 219]; test data set). The classification and regression tree prediction algorithm was applied to predict death, functional outcome, and ventriculoperitoneal (VP) shunt dependency. Chi-square automatic interaction detection was applied to predict delayed cerebral infarction on days 1, 3, and 7. RESULTS The overall mortality was 18.4%. The accuracy of the decision tree models was good for survival on day 1 and favorable functional outcome at all time points, with a difference between the training and test data sets of < 5%. Prediction accuracy for survival on day 1 was 75.2%. The most important differentiating factor was the interleukin-6 (IL-6) level on day 1. Favorable functional outcome, defined as Glasgow Outcome Scale scores of 4 and 5, was observed in 68.6% of patients. Favorable functional outcome at all time points had a prediction accuracy of 71.1% in the training data set, with procalcitonin on day 1 being the most important differentiating factor at all time points. A total of 148 patients (27%) developed VP shunt dependency. The most important differentiating factor was hyperglycemia on admission. CONCLUSIONS The multiple variable analysis capability of decision trees enables exploration of dependent variables in the context of multiple changing influences over the course of an illness. The decision tree currently generated increases awareness of the early systemic stress response, which is seemingly pertinent for prognostication.

  17. Successful preemptive surgical division of type 2-congenital extrahepatic portosystemic shunt in children.

    PubMed

    Nii, Akira; Takehara, Hiro-o; Kuyama, Hisako; Shimada, Mitsuo

    2009-02-01

    A congenital extrahepatic portosystemic shunt (CEPS) is a rare abnormality. The shunts are classified into 2 types. Of these, a type 2-shunt is a side-to-side one, which may be treated by a simple shunt division. The aim of this retrospective study was to clarify the effects of a surgical shunt division on 4 children with type 2-CEPS. Between June 2002 and June 2008, 4 children with type 2-CEPS underwent a surgical shunt division. Various clinical factors of each patient, including shunt types, shut ratios evaluated by portal scintigraphy using (123)I-iodoamphetamine, serum levels of ammonia and total bile acids before and after surgery were evaluated. Two children had a conventional open surgery and the other two had a laparoscopic surgery. The serum levels of ammonia as well as total bile acids of these children decreased significantly to the normal levels within a month after the surgical shunt divisions. All the children had a better clinical course. A shunt division, especially by laparoscopic surgery, is an effective therapy for type 2-CEPS. To the best of our knowledge by reviewing literatures, our cases are the youngest ones treated by laparoscopic shunt division.

  18. Hot-spot heating susceptibility due to reverse bias operating conditions

    NASA Technical Reports Server (NTRS)

    Gonzalez, C. C.

    1985-01-01

    Because of field experience (indicating that cell and module degradation could occur as a result of hot spot heating), a laboratory test was developed at JPL to determine hot spot susceptibility of modules. The initial hot spot testing work at JPL formed a foundation for the test development. Test parameters are selected as follows. For high shunt resistance cells, the applied back bias test current is set equal to the test cell current at maximum power. For low shunt resistance cells, the test current is set equal to the cell short circuit current. The shadow level is selected to conform to that which would lead to maximum back bias voltage under the appropriate test current level. The test voltage is determined by the bypass diode frequency. The test conditions are meant to simulate the thermal boundary conditions for 100 mW/sq cm, 40C ambient environment. The test lasts 100 hours. A key assumption made during the development of the test is that no current imbalance results from the connecting of multiparallel cell strings. Therefore, the test as originally developed was applicable for single string case only.

  19. Distribution of extrahepatic congenital portosystemic shunt morphology in predisposed dog breeds

    PubMed Central

    2012-01-01

    Background An inherited basis for congenital extrahepatic portosystemic shunts (EHPSS) has been demonstrated in several small dog breeds. If in general both portocaval and porto-azygous shunts occur in breeds predisposed to portosystemic shunts then this could indicate a common genetic background. This study was performed to determine the distribution of extrahepatic portocaval and porto-azygous shunts in purebred dog populations. Results Data of 135 client owned dogs diagnosed with EHPSS at the Faculty of Veterinary Medicine of Utrecht University from 2001 – 2010 were retrospectively analyzed. The correlation between shunt localization, sex, age, dog size and breed were studied. The study group consisted of 54 males and 81 females from 24 breeds. Twenty-five percent of dogs had porto-azygous shunts and 75% had portocaval shunts. Of the dogs with porto-azygous shunts only 27% was male (P = 0.006). No significant sex difference was detected in dogs with a portocaval shunt. Both phenotypes were present in almost all breeds represented with more than six cases. Small dogs are mostly diagnosed with portocaval shunts (79%) whereas both types are detected. The age at diagnosis in dogs with porto-azygous shunts was significantly higher than that of dogs with portocaval shunts (P < 0.001). Conclusion The remarkable similarity of phenotypic variation in many dog breeds may indicate common underlying genes responsible for EHPSS across breeds. The subtype of EHPSS could be determined by a minor genetic component or modulating factors during embryonic development. PMID:22784395

  20. Distribution of extrahepatic congenital portosystemic shunt morphology in predisposed dog breeds.

    PubMed

    Van den Bossche, Lindsay; van Steenbeek, Frank G; Favier, Robert P; Kummeling, Anne; Leegwater, Peter A J; Rothuizen, Jan

    2012-07-11

    An inherited basis for congenital extrahepatic portosystemic shunts (EHPSS) has been demonstrated in several small dog breeds. If in general both portocaval and porto-azygous shunts occur in breeds predisposed to portosystemic shunts then this could indicate a common genetic background. This study was performed to determine the distribution of extrahepatic portocaval and porto-azygous shunts in purebred dog populations. Data of 135 client owned dogs diagnosed with EHPSS at the Faculty of Veterinary Medicine of Utrecht University from 2001 - 2010 were retrospectively analyzed. The correlation between shunt localization, sex, age, dog size and breed were studied. The study group consisted of 54 males and 81 females from 24 breeds. Twenty-five percent of dogs had porto-azygous shunts and 75% had portocaval shunts. Of the dogs with porto-azygous shunts only 27% was male (P = 0.006). No significant sex difference was detected in dogs with a portocaval shunt. Both phenotypes were present in almost all breeds represented with more than six cases. Small dogs are mostly diagnosed with portocaval shunts (79%) whereas both types are detected. The age at diagnosis in dogs with porto-azygous shunts was significantly higher than that of dogs with portocaval shunts (P < 0.001). The remarkable similarity of phenotypic variation in many dog breeds may indicate common underlying genes responsible for EHPSS across breeds. The subtype of EHPSS could be determined by a minor genetic component or modulating factors during embryonic development.

  1. PPAR-γ Regulates Carnitine Homeostasis and Mitochondrial Function in a Lamb Model of Increased Pulmonary Blood Flow

    PubMed Central

    Rafikov, Ruslan; Kumar, Sanjiv; Hou, Yali; Oishi, Peter E.; Datar, Sanjeev A.; Raff, Gary; Fineman, Jeffrey R.; Black, Stephen M.

    2012-01-01

    Objective Carnitine homeostasis is disrupted in lambs with endothelial dysfunction secondary to increased pulmonary blood flow (Shunt). Our recent studies have also indicated that the disruption in carnitine homeostasis correlates with a decrease in PPAR-γ expression in Shunt lambs. Thus, this study was carried out to determine if there is a causal link between loss of PPAR-γ signaling and carnitine dysfunction, and whether the PPAR-γ agonist, rosiglitazone preserves carnitine homeostasis in Shunt lambs. Methods and Results siRNA-mediated PPAR-γ knockdown significantly reduced carnitine palmitoyltransferases 1 and 2 (CPT1 and 2) and carnitine acetyltransferase (CrAT) protein levels. This decrease in carnitine regulatory proteins resulted in a disruption in carnitine homeostasis and induced mitochondrial dysfunction, as determined by a reduction in cellular ATP levels. In turn, the decrease in cellular ATP attenuated NO signaling through a reduction in eNOS/Hsp90 interactions and enhanced eNOS uncoupling. In vivo, rosiglitazone treatment preserved carnitine homeostasis and attenuated the development of mitochondrial dysfunction in Shunt lambs maintaining ATP levels. This in turn preserved eNOS/Hsp90 interactions and NO signaling. Conclusion Our study indicates that PPAR-γ signaling plays an important role in maintaining mitochondrial function through the regulation of carnitine homeostasis both in vitro and in vivo. Further, it identifies a new mechanism by which PPAR-γ regulates NO signaling through Hsp90. Thus, PPAR-γ agonists may have therapeutic potential in preventing the endothelial dysfunction in children with increased pulmonary blood flow. PMID:22962578

  2. Correlation between lumbo-ventricular perfusion and MRI-CSF flow studies in idiopathic normal pressure hydrocephalus.

    PubMed

    Hakim, R; Black, P M

    1998-01-01

    After the initial description of normal pressure hydrocephalus (NPH) and its clinical triad, there has been a continuous interest from clinicians and researchers to set different diagnostic criteria that would make the selection of candidates for shunt surgery easier and more precise. A preliminary group of 12 patients was given a diagnosis of idiopathic normal pressure hydrocephalus by clinical and radiologic criteria. Each patient underwent two different tests: a magnetic resonance imaging-cerebrospinal fluid (MRI-CSF) flow study and a lumbo-ventricular perfusion test. The purpose was to compare the correlation of the results obtained with these tests and the clinical results obtained after CSF diversion. Eleven patients were given shunts and one was managed with lumbar punctures. One year after treatment, 10 of the 12 patients had improved with good results. The MRI-CSF flow studies were reliable in six patients; there were five false negatives and one false positive. The lumbo-ventricular perfusion test showed reliability in nine patients; there were two false negatives and one false positive. In only three patients were the results of both of these tests in accordance with the outcome. Even though there are few patients in this study so far, the data suggests that at the present time the most predictive guides for the diagnosis of NPH and its outcome after shunting are the clinical criteria and the radiological findings in computed tomography (CT) and/or MRI rather than lumbo-ventricular perfusion and CSF flow studies.

  3. Over-drainage and persistent shunt-dependency in patients with idiopathic intracranial hypertension treated with shunts and bariatric surgery.

    PubMed

    Roth, Jonathan; Constantini, Shlomi; Kesler, Anat

    2015-01-01

    Idiopathic intracranial hypertension (IIH) may lead to visual impairment. Shunt surgery is indicated for refractory IIH-related symptoms that persist despite medical treatment, or those presenting with significant visual decline. Obesity is a risk factor for IIH; a reduction in weight has been shown to improve papilledema. Bariatric surgery (BS) has been suggested for treating IIH associated with morbid obesity. In this study, we describe a high rate of over-drainage (OD) seen in patients following shunts and BS. The study cohort includes 13 patients with IIH that underwent shunt surgery for treatment of the IIH-related symptoms. Six patients underwent BS in addition to the shunt surgery (but not concomitantly). Seven patients had only shunt surgeries with no BS. Data were collected retrospectively. BS effectively led to weight reduction (body mass index decreasing from 43 ± 4 to 28 ± 5). Patients undergoing BS had 1-6 (2.5 ± 1.9) shunt revisions for OD following BS, as opposed to 0-3 (1.4 ± 1.1) revisions prior to BS over similar time spans (statistically insignificant difference), and 0-6 (1.6 ± 2.5) revisions among the non-BS patients over a longer time span (statistically insignificant difference). Two patients in the BS group underwent shunt externalization and closure; however, they proved to be shunt-dependent. Patients with IIH that undergo shunt surgery and BS (not concomitantly) may suffer from OD symptoms, necessitating multiple shunt revisions, and valve upgrades. Despite BS being a valid primary treatment for some patients with IIH, among shunted patients, BS may not lead to resolution of IIH-related symptoms and patients may remain shunt-dependent.

  4. Outcome of shunting in idiopathic normal-pressure hydrocephalus and the value of outcome assessment in shunted patients.

    PubMed

    Klinge, Petra; Marmarou, Anthony; Bergsneider, Marvin; Relkin, Norman; Black, Peter McL

    2005-09-01

    To develop guidelines for assessing shunt outcome in patients with idiopathic normal-pressure hydrocephalus (INPH). To date, the literature available on this topic has been marked by disparate definitions of clinical improvement, varying postoperative follow-up protocols and periods, and substantial differences in the postoperative management. Because specific criteria for defining clinical improvement are seldom reported, conclusions drawn about shunt outcome may be subjective. A MEDLINE search back to 1966 was undertaken using the query NPH, normal-pressure hydrocephalus, shunting, shunt treatment, shunt response, outcome, and clinical outcome. The criteria for selection were studies that included INPH from 1966 to the present in which the outcome of INPH was reported in patient groups of 20 or more. To date, there is no standard for outcome assessment of shunt treatment in INPH. The variable improvement rates reported are not only because of different criteria for selection of patients but also because of different postoperative assessment procedures and follow-up intervals. Studies that have established fixed protocols for follow-up have shown that short- and long-term periods after shunting are determined by many factors. Whereas short-term results were more likely to be influenced by shunt-associated risks, long-term results were independent of factors inherent to the shunt procedure and shunt complications, i.e., death and morbidity related to concomitant cerebrovascular and vascular diseases. Studies have shown that beyond 1 year after surgery, these factors definitely influence the clinical effect of shunting, making the 1-year postshunt period a potential determinant of the shunt outcome. Guidelines for outcome assessment were developed on the basis of the available evidence and consensus of expert opinion.

  5. Evaluation of Mismatch Losses due to Shunts in industrial Silicon Photovoltaic Modules

    NASA Astrophysics Data System (ADS)

    Somasundaran, P.; Shilpi, M.; Gupta, R.

    2017-05-01

    In order to achieve higher efficiencies in photovoltaic module technology, it is important to characterize the shunts and other defects which degrade the performance of cells and modules as well as decrease their efficiency. These shunts also affect the reliability of cells and modules. It is important to understand how much fill factor and power loss is caused by the presence of shunts in the module. Shunts not only reduce the module power output, but also affect the I-V characteristics of the cell and hence the characteristics of the shunted cells are different from those of the shunt-free cells connected in the module leading to the mismatch effect. This is an interesting effect which has been systematically investigated in the present work. Moreover, the flow of increased shunt current will give rise to increased temperature in the region of shunt, which will affect the cell and hence module performance. In the present study, the distributed diode model has been extended to the module level and applied to evaluate the electrical mismatch losses and thermal mismatch losses due to shunts in industrial Silicon PV modules.

  6. Measurements of left-to-right intracardiac shunting in adults: oximetric versus indicator dilution techniques.

    PubMed

    Hillis, L D; Winniford, M D; Jackson, J A; Firth, B G

    1985-01-01

    Of the various techniques that are available to assess the presence and magnitude of intracardiac shunting, oximetry and indicator dilution are used most frequently. This study was performed to compare these methods in adult patients with pure left-to-right intracardiac shunting. In 27 patients [12 men, 15 women, aged 32 +/- 12 (mean +/- SD) years], shunt magnitude was assessed in close temporal proximity by both techniques. The oximetric percentage left-to-right shunt averaged 55 +/- 16%, whereas the indocyanine green dye percentage shunt was significantly less (36 +/- 14%, p less than 0.001). The oximetric percentage shunt exceeded the indocyanine green dye percentage shunt in 26 and did so by greater than 20% in 23 patients. Thus, there is a substantial difference in shunt magnitude between the oximetric and the indicator dilution techniques. In infants, indicator dilution yields results that are larger than those obtained with the oximetric method. Conversely, in adults, the indicator dilution technique gives results that are consistently smaller than those obtained with oximetry. As a result, the decision regarding therapy of an intracardiac shunt should be made with this in mind.

  7. Outcome of infants shunted for post-haemorrhagic ventricular dilatation.

    PubMed

    Hislop, J E; Dubowitz, L M; Kaiser, A M; Singh, M P; Whitelaw, A G

    1988-08-01

    Between April 1980 and March 1986, 19 infants underwent cerebrospinal fluid (CSF) shunting procedures for post-haemorrhagic ventricular dilatation at the Hammersmith Hospital, London. A total of 58 shunt-related procedures have been performed on these children. The major perioperative complication was seizure activity (eight children). Postoperative complications included infection (12 shunts) and blockage (29 shunts). Prophylactic antibiotics failed to prevent shunt infection. The likelihood of the first shunt failing was significantly reduced by greater weight of the infant and lower CSF protein at surgery. Long-term outcome was poor: three have died and another four are quadriplegic with severe mental retardation. Only four children are developmentally normal. These outcomes cannot be related to the shunt surgery or its complications, but correlate best with pre-operative parenchymal brain-lesions, as shown on ultrasound scans.

  8. Shunt diameter in agenesis of the ductus venosus with extrahepatic portosystemic shunt impacts on prognosis.

    PubMed

    Shen, O; Valsky, D V; Messing, B; Cohen, S M; Lipschuetz, M; Yagel, S

    2011-02-01

    Agenesis of the ductus venosus (ADV) is a rare condition in which there are two variants of umbilical vein drainage: intrahepatic shunt or extrahepatic (portosystemic) shunt. It has been posited that the extrahepatic variant carries a poorer prognosis. However, in the absence of associated anomalies there is still a wide variation in outcome. We evaluated the portal system in cases of ADV and aimed to identify parameters that might predict outcome. We conducted a retrospective study of cases of ADV with extrahepatic shunt that had been examined in two centers, and collected new cases prospectively. The route of the shunt was depicted using two-dimensional (2D) and three-dimensional (3D) ultrasound imaging. In an attempt to characterize portal system and shunt developmental variations and their possible impact on outcome, the diameter of the shunt was compared with the diameter of the umbilical vein and the entire portal vasculature was assessed. Poor outcome was defined as persistent morbidity or fetal or neonatal death. Twenty-two cases of ADV were identified: nine retrospectively and 13 prospectively. Aberrant shunts from the umbilical vein were identified to the right atrium, coronary sinus, inferior vena cava (IVC) and iliac vein. In seven of 22 cases (32%) a wide connection was observed. In six of these seven cases (86%) the outcome was poor, including four with severe associated anomalies and two with hepatic dysfunction. In five of these cases, cardiomegaly with tricuspid regurgitation was observed, as well as underdevelopment of the portal system. In only five of 15 cases with a narrow shunt (33%) was the outcome poor, and in all five cases the poor outcome was related to associated anomalies. In cases of ADV with extrahepatic shunt, portal system development is impacted by the diameter of the shunt. If the shunt is narrow, the portal system will have developed normally. A wide shunt is associated with underdevelopment or absence of the portal system. In cases of ADV with extrahepatic shunt, prognosis is determined by the severity of associated anomalies, the diameter of the shunt and development of the portal system. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.

  9. Internal carotid artery rupture caused by carotid shunt insertion

    PubMed Central

    Illuminati, Giulio; Caliò, Francesco G.; Pizzardi, Giulia; Vietri, Francesco

    2015-01-01

    Introduction Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. Presentation of case A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Discussion Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Conclusion Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. PMID:26255001

  10. [Mesenteric-cava shunt's results with autologous jugular vein graft in children with pre-sinusoidal portal hypertension].

    PubMed

    Leal, N; López Santamaría, M; Gámez, M; Murcia, J; Andolfi, G; Berrocal, T; Frauca, E; Jara, P; Tovar, J

    2002-07-01

    Presinusoidal portal hypertension (PPH) in children evaluates without functional hepatic damage, and with the time, trends to compensate through the creation of spontaneous portosystemic shunts. Nevertheless, some patients suffer episodes of gastrointestinal bleeding (GIB) that because of its frequency or severity, force to propose the change of surgical treatment. To evaluate the results of the mesocaval shunt (MCS) with autologous jugular vein in children with PPH. Among the 32 children with PPH treated in our Hospital in the last 7 years, 10 had episodes of GIB that forced to perform a surgical shunt. The types of shunt were distal splenorenal in 3 patients and mesocaval in 7. These 7 cases are the material of this study. The origin of the PPH was a cavernomatosis transformation of the portal vein in 6 cases and a congenital hepatic fibrosis in 1. Before the surgery the average number of episodes of GIB was 9 (range 2-15); all the patients needed transfusion of blood products and variceal sclerosis. In 2 cases a tamponade with the Sengtaken balloon was required and 5 patients were treated with somatostatin and propranolol. The Doppler ultrasounds revealed and intense hepatofugal collateral circulation in all the cases. The initial flow through the shunt was adequate in all the patients except one who required a percutaneous balloon dilatation. Only this patient has suffered an episode of GIB. The hyperesplenism signs disappeared or improved in all the seven cases and the collateral circulation was significantly reduced. The pressure in the splenic territory decreased around 50% in the 4 patients that was measured. There were no cases of encephalopasty and only one child with congenital hepatic fibrosis shows signs of mild hepatic disfunction. The medium follow up post-shunt is 32 months (range 8 m-6 years). The MCS prevents the GIB in the PPH not responsive to the conservative treatment; its effectiveness is related with an adequate permeability though the graft and at least in the cases with portal cavernomatosis (the most frequent in children) doesn't produce hepatic dysfunction. Doppler ultrasounds give a very precise information about the post-surgical situation and are an excellent method of follow up.

  11. Congenital portosystemic shunts: diagnosis and treatment.

    PubMed

    Franchi-Abella, Stéphanie; Gonzales, Emmanuel; Ackermann, Oanez; Branchereau, Sophie; Pariente, Danièle; Guérin, Florent

    2018-05-05

    Congenital portosystemic shunts (CPSS) are rare vascular malformations that create an abnormal connection between portal and systemic veins resulting in complete or partial diversion of the portal flow away from the liver to the systemic venous system. Different anatomic types exist and several classifications have been proposed. They can be associated with other malformations especially cardiac and heterotaxia. The main complications include hepatic encephalopathy, liver tumors, portopulmonary hypertension, and pulmonary arteriovenous shunts. Diagnosis relies on imaging, and prenatal diagnosis is possible. Spontaneous closure of the CPSS is possible in some anatomic forms during the first year of life. When the CPSS remains patent, radiologic or surgical closure of the CPSS may prevent, resolve, or stabilize complications. Interventional radiology plays a key role for both the preoperative evaluation with occlusion test to assess the exact anatomy and to measure portal pressure after occlusion of the CPSS. Endovascular closure is the first option for treatment when possible.

  12. Noncirrhotic Extrahepatic Portosystemic Shunt Causing Adult-Onset Encephalopathy Treated with Endovascular Closure

    PubMed Central

    Elnekave, Eldad; Belenky, Eugenia; Van der Veer, Lindsley

    2015-01-01

    A 54-year-old woman presented with a six-month history of episodic confusion and progressive ataxia. A comprehensive metabolic panel was notable for elevated values of alkaline phosphatase (161 U/L), total bilirubin (1.5 mg/dL), and serum ammonia of 300 umol/L (normal range 9–47). Hepatitis panel, relevant serological tests, tumor markers (CA-19-9, CEA), and urea cycle enzyme studies were unrevealing. Lactulose and rifaximin therapy failed to normalize serum ammonia levels. Imaging revealed a structural vascular abnormality communicating between an enlarged inferior mesenteric vein and the left renal vein, measuring 16 mm in greatest diameter. The diagnosis of congenital extrahepatic portosystemic shunt was made and endovascular shunt closure was performed using a 22 mm Amplatzer II vascular plug. Within a day, serum ammonia levels normalized. Lactulose and rifaximin were discontinued, and confusion and ataxia resolved. PMID:26199783

  13. Experimental study of an adaptive elastic metamaterial controlled by electric circuits

    NASA Astrophysics Data System (ADS)

    Zhu, R.; Chen, Y. Y.; Barnhart, M. V.; Hu, G. K.; Sun, C. T.; Huang, G. L.

    2016-01-01

    The ability to control elastic wave propagation at a deep subwavelength scale makes locally resonant elastic metamaterials very relevant. A number of abilities have been demonstrated such as frequency filtering, wave guiding, and negative refraction. Unfortunately, few metamaterials develop into practical devices due to their lack of tunability for specific frequencies. With the help of multi-physics numerical modeling, experimental validation of an adaptive elastic metamaterial integrated with shunted piezoelectric patches has been performed in a deep subwavelength scale. The tunable bandgap capacity, as high as 45%, is physically realized by using both hardening and softening shunted circuits. It is also demonstrated that the effective mass density of the metamaterial can be fully tailored by adjusting parameters of the shunted electric circuits. Finally, to illustrate a practical application, transient wave propagation tests of the adaptive metamaterial subjected to impact loads are conducted to validate their tunable wave mitigation abilities in real-time.

  14. Shunting for normal pressure hydrocephalus (NPH).

    PubMed

    Esmonde, T; Cooke, S

    2002-01-01

    Since the condition was first described in 1965, the syndrome of normal pressure hydrocephalus (NPH) has conventionally been managed by placement of a cerebrospinal fluid (CSF) shunt. To determine the effectiveness of shunting procedures in promoting stability or improvement in the neurological symptoms and signs of NPH. The trials were identified from a search of the Specialized Register of the Cochrane Dementia and Cognitive Improvement Group on 26 June 2001 using the terms 'shunt*' and 'normal pressure hydrocephalus'. Studies included for analysis were those involving the placement of a CSF shunt for the treatment of NPH as part of a randomized controlled trial. No data matching the selection criteria were found. No randomized controlled trials of shunt placement versus no shunt were found. There is no evidence to indicate whether placement of a shunt is effective in the management of NPH.

  15. Investigating PID shunting in polycrystalline silicon modules via multiscale, multitechnique characterization

    DOE PAGES

    Harvey, Steven P.; Moseley, John; Norman, Andrew; ...

    2018-02-27

    We investigated the potential-induced degradation (PID) shunting mechanism in multicrystalline-silicon photovoltaic modules by using a multiscale, multitechnique characterization approach. Both field-stressed modules and laboratory-stressed mini modules were studied. We used photoluminescence, electroluminescence, and dark lock-in thermography imaging to identify degraded areas at the module scale. Small samples were then removed from degraded areas, laser marked, and imaged by scanning electron microscopy. We used simultaneous electron-beam induced current imaging and focused ion beam milling to mark around PID shunts for chemical analysis by time-of-flight secondary-ion mass spectrometry or to isolate individual shunt defects for transmission electron microscopy and atom-probe tomography analysis.more » By spanning a range of 10 orders of magnitude in size, this approach enabled us to investigate the root-cause mechanisms for PID shunting. We observed a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiNX/Si interface and is consistently observed at a concentration of 0.1% to 2% in shunted areas. Analysis of samples subjected to PID recovery, either activated by electron beam or thermal effects only, reveals that recovery of isolated shunts correlates with diffusion of sodium out of the structural defects to the silicon surface. We observed the role of oxygen and chlorine in PID shunting and found that those species - although sometimes present in structural defects where PID shunting was observed - do not play a consistent role in PID shunting.« less

  16. Hepatic vascular shunts: embryology and imaging appearances

    PubMed Central

    Bhargava, P; Vaidya, S; Kolokythas, O; Katz, D S; Dighe, M

    2011-01-01

    The purpose of this pictorial review is to understand the embryological basis of the development of congenital hepatic vascular shunts and to review the multimodality imaging appearances of congenital and acquired hepatic vascular shunts. Hepatic vascular shunts are commonly seen in imaging. Familiarity with their characteristic appearances is important in order to accurately characterise these shunts and diagnose the underlying disorders. PMID:22101582

  17. Treatment of refractory chylothorax with externalized pleuroperitoneal shunts in children.

    PubMed

    Wolff, A B; Silen, M L; Kokoska, E R; Rodgers, B M

    1999-09-01

    Traditional therapy for refractory chylothorax in the pediatric population has included pleurodesis and thoracic duct ligation. These procedures are associated with high morbidity and questionable success rates. We retrospectively reviewed our experience with 15 patients who underwent treatment for chylous effusions using pleuroperitoneal shunts with exteriorized pump chambers. Mean patient age at time of shunt placement was 2.1 (0.1 to 11.5) years and the most common indication (7 of 15) was refractory chylothorax following surgical correction of congenital heart disease. Mean chylothorax duration before shunt placement was 76 (5 to 810) days and shunts were in place for an average of 104 (12 to 365) days. A total of 19 chylous effusions (pleural or pericardial) were treated with shunts. Nine of 11 right-sided chylothoraces, 5 of 6 left-sided chylothoraces, and 2 of 2 chylopericardia resolved with shunt therapy (84% total). Pleuroperitoneal shunting failed to clear the effusion in 3 children. There were six episodes of shunt malfunction that were repaired and two episodes of infection. Inguinal or umbilical hernia developed in 4 patients. Externalized pleuroperitoneal shunting is a safe, effective, and minimally invasive treatment for children with refractory chylous effusions.

  18. Management of the ventriculo-peritoneal shunt in pediatric patients during robot-assisted laparoscopic urologic procedures.

    PubMed

    Marchetti, Pablo; Razmaria, Aria; Zagaja, Greg P; Gundeti, Mohan S

    2011-02-01

    Infection or malfunction of ventriculo-peritoneal (VP) shunts is a severe complication during laparoscopic surgery involving the gastrointestinal or urinary tract. It has been recently suggested to externalize the shunt or convert into a ventriculo-atrial shunt to prevent this complication with laparoscopic approach. Herein, we present a novel technique for management of the VP shunt during robot-assisted laparoscopic (RAL) urologic procedures. After port placement and diagnostic peritoneoscopy, an Endopouch bag (Ethicon Endo-Surgery) was inserted into the peritoneal cavity and the distal end of the shunt was placed into the pouch. The Endopouch suture was synched around the shunt and the pouch was placed in the subhepatic space during the surgery. The intraperitoneal pressure was maintained at 12 mm Hg during the entire procedure. Metronidazole, gentamicin, and vancomycin were administered as prophylaxis. Following the completion of the surgery and profuse irrigation of the peritoneal cavity, the shunt was repositioned within the peritoneum. We evaluated perioperative shunt-related complications. We used this technique in four patients with VP shunt undergoing RAL cystoplasty and appendicovesicostomy and/or colonic enema channel formation. The average age of the patient at surgery was 10.8 (7-14) years. One patient was converted to open because of failure to progress due to multiple adhesions and the shunt was externalized temporarily. At a mean follow-up of 13 (3-20) months, no shunt-related complications were seen. In our preliminary experience, the use of an intracorporeal Endopouch bag with controlled pneumoperitoneal pressure to protect the VP shunt may be an effective alternative to prevent complications related to it during RAL urologic surgery involving the gastrointestinal or urinary tract. Further studies will be needed to confirm our results.

  19. In utero repair of myelomeningocele: experimental pathophysiology, initial clinical experience, and outcomes.

    PubMed

    Farmer, Diana L; von Koch, Cornelia S; Peacock, Warwick J; Danielpour, Moise; Gupta, Nalin; Lee, Hanmin; Harrison, Michael R

    2003-08-01

    Experimental work raises the possibility that in utero repair of myelomeningocele (MMC) may improve lower extremity, bladder, and bowel function, ameliorate the Arnold-Chiari malformation, and decrease the need for postnatal shunting. We previously developed fetal lamb models to create and reverse lower extremity damage and the Arnold-Chiari malformation in utero. We then applied our extensive experience with fetal surgery, including fetal endoscopic (fetoscopic) surgical manipulation, to develop techniques for MMC repair. A tertiary referral center. All patients treated between 1998 and 2002 for a prenatally diagnosed MMC. Either fetoscopic MMC repair, fetoscopic patch repair, or limited maternal hysterotomy and microsurgical 3-layered fetal MMC repair was performed. Gestational age at delivery, survival, neurologic outcome, and need for ventricular shunting at 1 year. Complete fetoscopic repair was accomplished in 1 fetus. Two other fetuses underwent partial fetoscopic procedures. The remaining 10 patients underwent limited maternal hysterotomy and microsurgical 3-layered fetal MMC repair. Four of 13 patients died, and the mean gestational age at delivery of 11 fetuses born alive was 31 weeks. Five of 9 required ventricular shunting by age 1 year. In 2 patients, lower extremity function improved by more than 2 vertebral levels compared with prenatal ultrasonography. Five of 10 patients who lived longer than 3 weeks required postnatal wound revision within 7 days after birth. Fetoscopic repair, although feasible, does not yet yield optimal surgical results. Open surgical repair before 22 weeks' gestation is physiologically sound and technically feasible. One third of patients appear to be spared the need for a shunt at age 1 year, but improvement in distal neurologic function is less clear. Additionally, fetal mortality is associated with this procedure. Our results complement the data published by groups at Children's Hospital of Philadelphia, in Pennsylvania, and Vanderbilt University, Nashville, Tenn. A National Institutes of Health-sponsored prospective randomized trial is now underway at these 3 centers to compare fetal repair with postnatal repair.

  20. 49 CFR 236.838 - Wire, shunt.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Wire, shunt. 236.838 Section 236.838 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Wire, shunt. A wire forming part of a shunt circuit. ...

  1. 49 CFR 236.838 - Wire, shunt.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Wire, shunt. 236.838 Section 236.838 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Wire, shunt. A wire forming part of a shunt circuit. ...

  2. Ventriculosubgaleal shunts for posthemorrhagic hydrocephalus in premature infants.

    PubMed

    Willis, Brian K; Kumar, Cherukuri Ravi; Wylen, Esther L; Nanda, Anil

    2005-01-01

    The early management of posthemorrhagic hydrocephalus in premature infants is challenging and controversial. These infants need a temporary cerebrospinal fluid (CSF) diversion procedure until they gain adequate weight, and the blood and protein levels in CSF are reasonably low before permanent shunt can be placed. Various options are available with their associated advantages and disadvantages. Ventriculosubgaleal shunts have been recommended as a more physiologic and less invasive means of achieving this goal. We have performed this procedure in 6 premature infants to evaluate their effectiveness and complications. Six consecutive premature infants with posthemorrhagic hydrocephalus underwent placement of ventriculosubgaleal shunts over a 1-year period of time. We reviewed their clinical and imaging progress to assess the ability of the shunt to control hydrocephalus and the complication rates. In all 6 patients, the ventriculosubgaleal shunt controlled the progression of hydrocephalus as assessed by clinical and imaging parameters. A permanent shunt was avoided in 1 patient (16.6%). However, 4 patients developed shunt infections, 1 involving the ventriculosubgaleal shunt itself, and 3 immediately after conversion to ventriculoperitoneal shunt. The total infection rate of the series was 66.6%. All infections were caused by staphylococcus species. There was only a 1% shunt infection rate in our institution for all nonventriculosubgaleal shunts during the same period of time. Placement of ventriculosubgaleal shunts for interim CSF diversion in neonates with posthemorrhagic hydrocephalus is effective as a temporary method of CSF diversion. However, our experience has shown that it is associated with a unacceptably high CSF infection rate. A potential cause for infection is CSF stasis just beneath the extremely thin skin of the premature infants, promoting colonization by skin flora. CSF sampling before conversion to a permanent shunt and replacement of the proximal hardware, which has been in situ for a prolonged period, may decrease the infection rates. At present, the procedure is no longer performed at our institution.

  3. Intracardiac Shunting and Stroke in Children: A Systematic Review

    PubMed Central

    Dowling, Michael M.; Ikemba, Catherine M.

    2017-01-01

    In adults, patent foramen ovale or other potential intracardiac shunts are established risk factors for stroke via paradoxical embolization. Stroke is less common in children and risk factors differ. The authors examined the literature on intracardiac shunting and stroke in children, identifying the methods employed, the prevalence of detectible intracardiac shunts, associated conditions, and treatments. PubMed searches with keywords related to intracardiac shunting and stroke in children identified articles of interest. Additional articles were identified via citations in these articles or in reviews. The authors found that studies of intracardiac shunting in children with stroke are limited. No controlled studies were identified. Detection methods vary and the prevalence of echocardiographically detectible intracardiac shunting appears lower than reported in adults and autopsy studies. Defining the role of intracardiac shunting in pediatric stroke will require controlled studies with unified detection methods in populations stratified by additional risk factors for paradoxical embolization. Optimal treatment is unclear. PMID:21212453

  4. The gamma-aminobutyric acid shunt contributes to closing the tricarboxylic acid cycle in Synechocystis sp PCC 6803

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiong, W; Brune, D; Vermaas, WFJ

    2014-07-16

    A traditional 2-oxoglutarate dehydrogenase complex is missing in the cyanobacterial tricarboxylic acid cycle. To determine pathways that convert 2-oxoglutarate into succinate in the cyanobacterium Synechocystis sp. PCC 6803, a series of mutant strains, Delta sll1981, Delta slr0370, Delta slr1022 and combinations thereof, deficient in 2-oxoglutarate decarboxylase (Sll1981), succinate semialdehyde dehydrogenase (Slr0370), and/or in gamma-aminobutyrate metabolism (Slr1022) were constructed. Like in Pseudomonas aeruginosa, N-acetylornithine aminotransferase, encoded by slr1022, was shown to also function as gamma-aminobutyrate aminotransferase, catalysing gamma-aminobutyrate conversion to succinic semialdehyde. As succinic semialdehyde dehydrogenase converts succinic semialdehyde to succinate, an intact gamma-aminobutyrate shunt is present in Synechocystis. The Deltamore » sll1981 strain, lacking 2-oxoglutarate decarboxylase, exhibited a succinate level that was 60% of that in wild type. However, the succinate level in the Delta slr1022 and Delta slr0370 strains and the Delta sll1981/Delta slr1022 and Delta sll1981/Delta slr0370 double mutants was reduced to 20-40% of that in wild type, suggesting that the gamma-aminobutyrate shunt has a larger impact on metabolite flux to succinate than the pathway via 2-oxoglutarate decarboxylase. C-13-stable isotope analysis indicated that the gamma-aminobutyrate shunt catalysed conversion of glutamate to succinate. Independent of the 2-oxoglutarate decarboxylase bypass, the gamma-aminobutyrate shunt is a major contributor to flux from 2-oxoglutarate and glutamate to succinate in Synechocystis sp. PCC 6803.« less

  5. Asymptomatic Congenital Intrahepatic Portosystemic Shunt.

    PubMed

    Brown, Karen M; Hal, Hassan

    2009-01-01

    Congenital (spontaneous) intrahepatic portosystemic shunt is rare in the English literature. Most cases of portosystemic shunt occur after trauma, surgery, liver biopsy or as a result of chronic portal hypertension. Chronic shunting may result in encephalopathy, bleeding or hyperinsulinism. We report a case of an asymptomatic adult female with a presumed congenital intrahepatic portosystemic shunt and discuss the pertinent imaging findings and important key concepts related to this condition.

  6. Validated linear dynamic model of electrically-shunted magnetostrictive transducers with application to structural vibration control

    NASA Astrophysics Data System (ADS)

    Scheidler, Justin J.; Asnani, Vivake M.

    2017-03-01

    This paper presents a linear model of the fully-coupled electromechanical behavior of a generally-shunted magnetostrictive transducer. The impedance and admittance representations of the model are reported. The model is used to derive the effect of the shunt’s electrical impedance on the storage modulus and loss factor of the transducer without neglecting the inherent resistance of the transducer’s coil. The expressions are normalized and then shown to also represent generally-shunted piezoelectric materials that have a finite leakage resistance. The generalized expressions are simplified for three shunts: resistive, series resistive-capacitive, and inductive, which are considered for shunt damping, resonant shunt damping, and stiffness tuning, respectively. For each shunt, the storage modulus and loss factor are plotted for a wide range of the normalized parameters. Then, important trends and their impact on different applications are discussed. An experimental validation of the transducer model is presented for the case of resistive and resonant shunts. The model closely predicts the measured response for a variety of operating conditions. This paper also introduces a model for the dynamic compliance of a vibrating structure that is coupled to a magnetostrictive transducer for shunt damping and resonant shunt damping applications. This compliance is normalized and then shown to be analogous to that of a structure that is coupled to a piezoelectric material. The derived analogies allow for the observations and equations in the existing literature on structural vibration control using shunted piezoelectric materials to be directly applied to the case of shunted magnetostrictive transducers.

  7. Hypoxic Challenge Testing (Fitness to Fly) in children with complex congenital heart disease.

    PubMed

    Naqvi, Nitha; Doughty, Victoria L; Starling, Luke; Franklin, Rodney C; Ward, Simon; Daubeney, Piers E F; Balfour-Lynn, Ian M

    2018-02-14

    Commercial airplanes fly with an equivalent cabin fraction of inspired oxygen of 0.15, leading to reduced oxygen saturation (SpO 2 ) in passengers. How this affects children with complex congenital heart disease (CHD) is unknown. We conducted Hypoxic Challenge Testing (HCT) to assess need for inflight supplemental oxygen. Children aged <16 years had a standard HCT. They were grouped as (A) normal versus abnormal baseline SpO 2 (≥95% vs <95%) and (B) absence versus presence of an actual/potential right-to-left (R-L) shunt. We measured SpO 2 , heart rate, QT interval corrected for heart rate and partial pressure of carbon dioxide measured transcutaneously (PtcCO 2 ). A test failed when children with (1) normal baseline SpO 2 desaturated to 85%, (2) baseline SpO 2 85%-94% desaturated by 15% of baseline; and (3) baseline SpO 2 75%-84% desaturated to 70%. There were 68 children, mean age 3.3 years (range 10 weeks-14.5 years). Children with normal (n=36) baseline SpO 2 desaturated from median 99% to 91%, P<0.0001, and 3/36 (8%) failed the test. Those with abnormal baseline SpO 2 (n=32) desaturated from median 84% to 76%, P<0.0001, and 5/32 (16%) failed (no significant difference between groups). Children with no R-L shunt (n=25) desaturated from median 99% to 93%, P<0.0001, but 0/25 failed. Those with an actual/potential R-L shunt (n=43) desaturated from median 87% to 78%, P<0.0001, and 8/43 (19%) failed (difference between groups P<0.02). PtcCO 2 , heart rate and QT interval corrected for heart rate were unaffected by the hypoxic state. This is the first evidence to help guide which children with CHD need a preflight HCT. We suggest all children with an actual or potential R-L shunt should be tested. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Alteration of cerebral perfusion in patients with idiopathic normal pressure hydrocephalus measured by 3D perfusion weighted magnetic resonance imaging.

    PubMed

    Walter, Christof; Hertel, F; Naumann, E; Mörsdorf, M

    2005-12-01

    It is controversial whether alteration of cerebral perfusion plays an important role in the pathophysiology of patients with idiopathic normal pressure hydrocephalus (NPH) and can help to predict the outcome after shunt surgery. 28 patients with suspected NPH were examined clinically (Homburg Hydrocephalus Scale, walking test, incontinence protocol) and by 3D dynamic susceptibility based perfusion weighted magnetic resonance imaging (PWI-MRI) before and after cerebrospinal fluid release (spinal tap test, STT). The perfusion parameters (negative integral (NI), time of arrival (T0), time to peak (TTP), mean transit time, and the difference TTP-T0 were analysed. Three different groups of patients were identified preoperatively: In group 1 seven patients showed an increase in the cerebral perfusion and a clinical improvement after STT. The second group (9 patients) also revealed an increase of the cerebral perfusion, but no significant alteration of the clinical assessment could be found. In the third group neither the cerebral perfusion nor the clinical assessment changed. 14 of the 16 patients (group 1 and 2) were examined three months after shunt placement. 11 patients showed a good or excellent result, 2 patients revealed a fair assessment, and only 1 patient had transiently improved. No patient was downgraded after shunting. In the patient group 1 and 2 the NI increased significantly (effect size: 34%), whereas in group 3 no significant alteration of NI was observed. PWI-MRI improves the prediction of outcome after shunt placement in patients with NPH and can offer new insights into the pathophysiology.

  9. Repeated assessment of suspected normal pressure hydrocephalus in non-shunted cases. A prospective study based on the constant rate lumbar infusion test.

    PubMed

    Czepko, Ryszard; Cieslicki, Krzysztof

    2016-05-01

    Only a few reports have been published on the natural history of non-shunted patients suspected of having NPH. The aim of this study is to follow up a group of such cases. It was possible to follow up 27 patients who had not been qualified for shunting after the primary diagnosis. An assessment of Hakim's triad was performed, together with an analysis of radiological parameters and the results of lumbar infusion tests (LITs), both on admission and at the later date (on average, after 5.6 months). All parameters were analyzed with respect to periventricular lucency (PVL), atrophy, type of NPH, and the age of the patients. There were no deteriorations and six patients improved. Those who were over 50 and who had no PVL or secondary NPH tended to improve more frequently. Significant improvement of dementia was noted (p = 0.042) in all cases, and in the group of patients without PVL (p = 0.04). The size of the ventricles did not change significantly. The values of the resistance to outflow (R), elastance (E), and ICP remained stable. Analysis of our series revealed that the patients suspected of having NPH who had not been qualified for shunting did not deteriorate, while some of them even improved significantly as far as the level of dementia was concerned. As the CT and LIT parameters remained stable, there were no indications for repeating these examinations, at least within the period of nearly 6 months, which followed the primary diagnosis.

  10. Internal carotid artery rupture caused by carotid shunt insertion.

    PubMed

    Illuminati, Giulio; Caliò, Francesco G; Pizzardi, Giulia; Vietri, Francesco

    2015-01-01

    Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. FSI simulation of CSF hydrodynamic changes in a large population of non-communicating hydrocephalus patients during treatment process with regard to their clinical symptoms

    PubMed Central

    2018-01-01

    3D fluid-structure interaction modelling was utilized for simulation of 13 normal subjects, 11 non-communicating hydrocephalus (NCH) patients at pre-treatment phase, and 3 patients at five post-treatment phases. Evaluation of ventricles volume and maximum CSF pressure (before shunting) following results validation indicated that these parameters were the most proper hydrodynamic indices and the NCH type doesn’t have any significant effect on changes in two indices. The results confirmed an appropriate correlation between these indices although the correlation decreased slightly after the occurrence of disease. NCH raises the intensity of vortex and pulsatility (2.4 times) of CSF flow while the flow remains laminar. On day 18 after shunting, the CSF pressure decreased 81.0% and all clinical symptoms of patients vanished except for headache. Continuing this investigation during the treatment process showed that maximum CSF pressure is the most sensitive parameter to patients’ clinical symptoms. Maximum CSF pressure has decreased proportional to the level of decrease in clinical symptoms and has returned close to the pressure range in normal subjects faster than other parameters and simultaneous with disappearance of patients’ clinical symptoms (from day 81 after shunting). However, phase lag between flow rate and pressure gradient functions and the degree of CSF pulsatility haven’t returned to normal subjects’ conditions even 981 days after shunting and NCH has also caused a permanent volume change (of 20.1%) in ventricles. Therefore, patients have experienced a new healthy state in new hydrodynamic conditions after shunting and healing. Increase in patients’ intracranial compliance was predicted with a more accurate non-invasive method than previous experimental methods up to more than 981 days after shunting. The changes in hydrodynamic parameters along with clinical reports of patients can help to gain more insight into the pathophysiology of NCH patients. PMID:29708982

  12. Diffusion tensor imaging detects early brain microstructure changes before and after ventriculoperitoneal shunt in children with high intracranial pressure hydrocephalus

    PubMed Central

    Zhao, Cailei; Li, Yongxin; Cao, Weiguo; Xiang, Kui; Zhang, Heye; Yang, Jian; Gan, Yungen

    2016-01-01

    Abstract To explore the use of diffusion tensor imaging (DTI) parameters in the quantitative assessment of early brain microstructure changes before and after ventriculoperitoneal shunt in children with high intracranial pressure hydrocephalus. Ten patients with communicating hydrocephalus (age: 2–36 months) and 14 age-/gender-matched controls (age: 2–36 months) were enrolled in this study. All patients underwent the ventriculoperitoneal shunt procedure. The imaging data were collected before and 3 months after the operation. Regions of interests (ROIs) included the white matter near the frontal horn of the lateral ventricles (FHLV), the occipital horn of the lateral ventricles (OHLV), occipital subcortical (OS) area, frontal subcortical (FS) area, and thalamus. Fractional anisotropies (FA) and apparent diffusion coefficients (ADC) of the ROIs before and after ventriculoperitoneal shunt were compared between the patients and the controls. Three months after surgery, the patients recovered from the surgery with ameliorated intracranial pressure and slight improvement of clinical intelligence scale and motor scale. Before ventriculoperitoneal shunt, the FA values (except the right FHLV) were significantly decreased and the ADC values were significantly increased in the patients with hydrocephalus, compared with the controls. After the ventriculoperitoneal shunt, the FA values in the FHLV and OHLV of the patients were similar to the controls, but the FA values in other ROIs were still significantly lower than controls. The ADC values in the FS and OS white matter areas of the patients were similar to the controls; however, the ADC values in other ROIs were still significantly higher in patients. The increase of FA and the reduction in ADC in the ROIs preceded the clinical function improvement in patients with high intracranial pressure hydrocephalus and reflected the early changes in brain tissue microstructure, such as the compression of the white matter areas in the ROIs. PMID:27759635

  13. Normal pressure hydrocephalus: Diagnostic and predictive evaluationon

    PubMed Central

    Damasceno, Benito Pereira

    2009-01-01

    In typical cases, normal pressure hydrocephalus (NPH) manifests itself with the triad of gait disturbance, which begins first, followed by mental deterioration and urinary incontinence associated with ventriculomegaly (on CT or MRI) and normal cerebrospinal fluid (CSF) pressure. These cases present minor diagnostic difficulties and are the most likely to improve after shunting. Problems arise when NPH shows atypical or incomplete clinical manifestations (25–50% of cases) or is mimicked by other diseases. In this scenario, other complementary tests have to be used, preferentially those that can best predict surgical outcome. Radionuclide cisternography, intracranial pressure monitoring (ICP) and lumbar infusion tests can show CSF dynamics malfunction, but none are able to confirm whether the patient will benefit from surgery. The CSF tap test (CSF-TT) is the only procedure that can temporarily simulate the effect of definitive shunt. Since the one tap CSF-TT has low sensitivity, it cannot be used to exclude patients from surgery. In such cases, we have to resort to a repeated CSF-TT (RTT) or continuous lumbar external drainage (LED). The most reliable prediction would be achieved if RTT or LED proved positive, in addition to the occurrence of B-waves during more than 50% of ICP recording time. This review was based on a PubMed literature search from 1966 to date. It focuses on clinical presentation, neuroimaging, complementary prognostic tests, and differential diagnosis of NPH, particularly on the problem of selecting appropriate candidates for shunt. PMID:29213603

  14. In situ cardiac perfusion reveals interspecific variation of intraventricular flow separation in reptiles.

    PubMed

    Joyce, William; Axelsson, Michael; Altimiras, Jordi; Wang, Tobias

    2016-07-15

    The ventricles of non-crocodilian reptiles are incompletely divided and provide an opportunity for mixing of oxygen-poor blood and oxygen-rich blood (intracardiac shunting). However, both cardiac morphology and in vivo shunting patterns exhibit considerable interspecific variation within reptiles. In the present study, we develop an in situ double-perfused heart approach to characterise the propensity and capacity for shunting in five reptile species: the turtle Trachemys scripta, the rock python Python sebae, the yellow anaconda Eunectes notaeus, the varanid lizard Varanus exanthematicus and the bearded dragon Pogona vitticeps To simulate changes in vascular bed resistance, pulmonary and systemic afterloads were independently manipulated and changes in blood flow distribution amongst the central outflow tracts were monitored. As previously demonstrated in Burmese pythons, rock pythons and varanid lizards exhibited pronounced intraventricular flow separation. As pulmonary or systemic afterload was raised, flow in the respective circulation decreased. However, flow in the other circulation, where afterload was constant, remained stable. This correlates with the convergent evolution of intraventricular pressure separation and the large intraventricular muscular ridge, which compartmentalises the ventricle, in these species. Conversely, in the three other species, the pulmonary and systemic flows were strongly mutually dependent, such that the decrease in pulmonary flow in response to elevated pulmonary afterload resulted in redistribution of perfusate to the systemic circuit (and vice versa). Thus, in these species, the muscular ridge appeared labile and blood could readily transverse the intraventricular cava. We conclude that relatively minor structural differences between non-crocodilian reptiles result in the fundamental changes in cardiac function. Further, our study emphasises that functionally similar intracardiac flow separation evolved independently in lizards (varanids) and snakes (pythons) from an ancestor endowed with the capacity for large intracardiac shunts. © 2016. Published by The Company of Biologists Ltd.

  15. Treatment of extrahepatic portal hypertension following a whipple procedure with a Rex shunt: report of a case.

    PubMed

    Reichman, Trevor W; Anthony, Tiffany; Testa, Giuliano

    2011-02-01

    The Rex shunt is a mesenteric vein to left portal vein decompressive shunt used for the treatment of portal vein thrombosis and portal hypertension. Its use has been reported primarily in the pediatric population where portal vein thrombosis occurs with some frequency. The shunt is thought to represent a more physiologic shunt, since it restores hepatopedal blood flow through the liver. This report describes the use of this shunt in an adult who had frequent gastrointestinal bleeding secondary to extrahepatic portal vein thrombosis, which occurred as a complication after a pancreaticoduodenectomy.

  16. Impedance Changes Indicate Proximal Ventriculoperitoneal Shunt Obstruction In Vitro.

    PubMed

    Basati, Sukhraaj; Tangen, Kevin; Hsu, Ying; Lin, Hanna; Frim, David; Linninger, Andreas

    2015-12-01

    Extracranial cerebrospinal fluid (CSF) shunt obstruction is one of the most important problems in hydrocephalus patient management. Despite ongoing research into better shunt design, robust and reliable detection of shunt malfunction remains elusive. The authors present a novel method of correlating degree of tissue ingrowth into ventricular CSF drainage catheters with internal electrical impedance. The impedance based sensor is able to continuously monitor shunt patency using intraluminal electrodes. Prototype obstruction sensors were fabricated for in-vitro analysis of cellular ingrowth into a shunt under static and dynamic flow conditions. Primary astrocyte cell lines and C6 glioma cells were allowed to proliferate up to 7 days within a shunt catheter and the impedance waveform was observed. During cell ingrowth a significant change in the peak-to-peak voltage signal as well as the root-mean-square voltage level was observed, allowing the impedance sensor to potentially anticipate shunt malfunction long before it affects fluid drainage. Finite element modeling was employed to demonstrate that the electrical signal used to monitor tissue ingrowth is contained inside the catheter lumen and does not endanger tissue surrounding the shunt. These results may herald the development of "next generation" shunt technology that allows prediction of malfunction before it affects patient outcome.

  17. Evaluation of in vivo behavior of ameroid ring constrictors in dogs with congenital extrahepatic portosystemic shunts using computed tomography.

    PubMed

    Hunt, Geraldine B; Culp, William T N; Mayhew, Kelli N; Mayhew, Philipp; Steffey, Michele A; Zwingenberger, Allison

    2014-10-01

    To evaluate the in vivo pattern of ameroid constrictor closure of congenital extrahepatic portosystemic shunts in dogs. Prospective study. Dogs (n = 22) with congenital extrahepatic portosystemic shunts. Contrast-enhanced computed tomography was performed immediately before, and at least 8 weeks after placement of ameroid ring constrictors. Plastic-encased ameroid constrictors were used in 17 dogs and metal constrictors in 5 dogs. Presence of residual flow through the portosystemic shunt, additional anomalous vessels, acquired shunts and soft tissue associated with the ameroid constrictor was recorded. Postoperative internal diameter was recorded for the 17 plastic constrictors. Correlations between internal diameter and pre- and postoperative serum protein concentration were analyzed. No ameroid constrictor closed completely: shunt occlusion was always dependent on soft tissue within the ameroid ring. Residual flow through the shunt was present in 4 dogs (18%), although this caused persistent elevation of shunt fraction in only 1 dog (dog 8). The change in ameroid constrictor internal diameter was not significantly correlated with serum protein concentration. Complete shunt occlusion after AC placement is usually dependent on soft tissue reaction. Ameroid constrictors ≥5 mm diameter may not promote complete shunt occlusion. © Copyright 2014 by The American College of Veterinary Surgeons.

  18. Effect of bladder augmentation on VP shunt failure rates in spina bifida.

    PubMed

    Gonzalez, Dani O; Cooper, Jennifer N; McLeod, Daryl J

    2017-12-11

    Most patients with spina bifida require ventriculoperitoneal (VP) shunt placement. Some also require bladder augmentation, which may increase the risk of VP shunt malfunction and/or failure. The aim of this study was to assess whether bladder augmentation affects the rate of VP shunt failure in this population. Using the Pediatric Health Information System, we studied patients with spina bifida born between 1992 and 2014 who underwent VP shunt placement. Using conditional logistic regression, we compared age- and hospital-matched patients who did and did not undergo a bladder augmentation to determine their difference in rates of VP shunt failure. There were 4192 patients with spina bifida who underwent both surgical closure and VP shunt placement. Of these, 203 patients with bladder augmentation could be matched to 593 patients without bladder augmentation. VP shunt failure occurred within 2 years in 7.7% of patients, the majority of whom were in the group who underwent bladder augmentation (87%). After adjusting for confounders, undergoing bladder augmentation was independently associated with VP shunt failure (HR: 33.5, 95% CI: 13.15-85.44, p< 0.001). Bladder augmentation appears to be associated with VP shunt failure. Additional studies are necessary to better define this relationship and identify risk-reduction techniques.

  19. Improvement in social function and health-related quality of life after shunt surgery for idiopathic normal-pressure hydrocephalus.

    PubMed

    Petersen, Jakob; Hellström, Per; Wikkelsø, Carsten; Lundgren-Nilsson, Asa

    2014-10-01

    To investigate the impact of shunt surgery on the activity, participation, autonomy, and health-related quality of life (HRQOL) of patients with idiopathic normal-pressure hydrocephalus (iNPH) as well as the effect on caregiver burden. Thirty-seven patients (median age 70 years, range 50-89 years) with iNPH were evaluated before and 6 months after surgery. Symptoms and signs were assessed by the iNPH scale, activities of daily living (ADL) with the Functional Independence Measure (FIM) and Assessment of Motor and Process Skills (AMPS), autonomy and participation with Impact on Participation and Autonomy (IPA), and caregiver burden with the Caregiver Burden Scale (CBS). HRQOL was evaluated with the EQ-5D (EuroQol Group-5 Dimension health survey). Twenty-four patients (65%) improved clinically (iNPH scale score) and 31 (86%) improved their HRQOL after surgery, almost to the same level as found in the normal population. The patients became more independent in physical and cognitive activities, and participation and autonomy improved. The caregiver burden was decreased among caregivers to male patients but remained unchanged on the overall group level. After shunt surgery, patients with iNPH showed improvement in most aspects of social life, they became more independent, and their quality of life returned to nearly normal.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harvey, Steven P.; Moseley, John; Norman, Andrew

    We investigated the potential-induced degradation (PID) shunting mechanism in multicrystalline-silicon photovoltaic modules by using a multiscale, multitechnique characterization approach. Both field-stressed modules and laboratory-stressed mini modules were studied. We used photoluminescence, electroluminescence, and dark lock-in thermography imaging to identify degraded areas at the module scale. Small samples were then removed from degraded areas, laser marked, and imaged by scanning electron microscopy. We used simultaneous electron-beam induced current imaging and focused ion beam milling to mark around PID shunts for chemical analysis by time-of-flight secondary-ion mass spectrometry or to isolate individual shunt defects for transmission electron microscopy and atom-probe tomography analysis.more » By spanning a range of 10 orders of magnitude in size, this approach enabled us to investigate the root-cause mechanisms for PID shunting. We observed a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiNX/Si interface and is consistently observed at a concentration of 0.1% to 2% in shunted areas. Analysis of samples subjected to PID recovery, either activated by electron beam or thermal effects only, reveals that recovery of isolated shunts correlates with diffusion of sodium out of the structural defects to the silicon surface. We observed the role of oxygen and chlorine in PID shunting and found that those species - although sometimes present in structural defects where PID shunting was observed - do not play a consistent role in PID shunting.« less

  1. [Hypervascularization syndrome of the penis following arterialization of the dorsal penile vein for erectile impotence].

    PubMed

    Fritsch, P; Grubauer, G; Hilty, N; Biedermann, H

    1989-07-01

    A hypervascularization syndrome following arterialization of the deep dorsal vein of the penis to amend venous erectile impotence is a rare cause of penile ulcers that has not previously been described in the dermatological literature. Arterialization is performed by installing a shunt from the inferior epigastric artery or a venous bypass from the femoral artery to the deep dorsal vein of the penis, resulting in a blockage of venous outflow and in retrograde inflow into the corpora cavernosa. Complications arise as a result of persistently elevated blood pressure in the deep venous system and the erectile tissue in 10-20% of cases and are most often linked to dilatation of the shunt: the consequences are enlargement and induration of the glans, hazard of phimosis and paraphimosis, pulsation of the penis, micturation difficulties and, ultimately, ulceration of the glans. Surgical reduction of the arterial inflow ("banding" of the shunt) is the only therapeutic procedure that reduces hypervascularization without compromising the newly gained erectile function.

  2. Gastric varices and hepatic encephalopathy: treatment with vascular plug and gelatin sponge-assisted retrograde transvenous obliteration--a primary report.

    PubMed

    Gwon, Dong Il; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo; Kim, Jin Hyoung; Shin, Ji Hoon; Ko, Heung Kyu; Song, Ho-Young

    2013-07-01

    To evaluate technical safety, clinical safety, and effectiveness of vascular plug-assisted retrograde transvenous obliteration (RTO) for treatment of gastric varices (GV) and hepatic encephalopathy (HE). This retrospective study was approved by the institutional review board; written informed consent was waived. From April 2009 to December 2011, 20 patients (13, GV; seven, HE) who had undergone vascular plug-assisted RTO were retrospectively evaluated. After retrograde transvenous placement of a vascular plug in the left adrenal vein or gastrorenal shunt, subsequent gelatin-sponge embolization of both gastrorenal shunt and GV was performed. Follow-up computed tomography (CT) and upper gastrointestinal tract endoscopy were performed; clinical and laboratory data were collected to evaluate primary (technical success, complications, clinical success) and secondary (change of liver function by using the Child-Pugh score, worsening of esophageal varices) end points. Laboratory data before and after vascular plug-assisted RTO were compared (paired-sample t test). Placement of the vascular plug and subsequent gelatin-sponge embolization were technically successful in all 20 patients, with no procedure-related complications. Follow-up CT within 1 week after vascular plug-assisted RTO showed complete thrombosis of GV and gastrorenal shunts in all patients. Clinical symptoms of HE completely resolved in all seven patients with HE; mean serum NH3 level of 127.4 μmol/L ± 58 (standard deviation) before vascular plug-assisted RTO decreased significantly to 28.1 μmol/L ± 9.8 within 1 week after vascular plug-assisted RTO (P = .002). Eighteen patients who underwent follow-up longer than 2 months showed complete obliteration of GV and gastrorenal shunts at CT and endoscopy. There were no cases of variceal bleeding or HE during mean follow-up of 422 days. Improvement in Child-Pugh score was observed in 12 of 18 (67%) patients 1 month after vascular plug-assisted RTO. Worsening of esophageal varices was observed in four (22%) patients at mean follow-up of 9.4 months. Vascular plug-assisted RTO is technically simple and safe and seems to be clinically effective for treatment of GV and HE.

  3. 49 CFR 236.725 - Circuit, switch shunting.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Circuit, switch shunting. 236.725 Section 236.725 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Circuit, switch shunting. A shunting circuit which is closed through contacts of a switch circuit...

  4. 49 CFR 236.725 - Circuit, switch shunting.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Circuit, switch shunting. 236.725 Section 236.725 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Circuit, switch shunting. A shunting circuit which is closed through contacts of a switch circuit...

  5. 49 CFR 236.725 - Circuit, switch shunting.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Circuit, switch shunting. 236.725 Section 236.725 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Circuit, switch shunting. A shunting circuit which is closed through contacts of a switch circuit...

  6. 49 CFR 236.725 - Circuit, switch shunting.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Circuit, switch shunting. 236.725 Section 236.725 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Circuit, switch shunting. A shunting circuit which is closed through contacts of a switch circuit...

  7. 49 CFR 236.725 - Circuit, switch shunting.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Circuit, switch shunting. 236.725 Section 236.725 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Circuit, switch shunting. A shunting circuit which is closed through contacts of a switch circuit...

  8. [Shunt and short circuit].

    PubMed

    Rangel-Abundis, Alberto

    2006-01-01

    Shunt and short circuit are antonyms. In French, the term shunt has been adopted to denote the alternative pathway of blood flow. However, in French, as well as in Spanish, the word short circuit (court-circuit and cortocircuito) is synonymous with shunt, giving rise to a linguistic and scientific inconsistency. Scientific because shunt and short circuit made reference to a phenomenon that occurs in the field of the physics. Because shunt and short circuit are antonyms, it is necessary to clarify that shunt is an alternative pathway of flow from a net of high resistance to a net of low resistance, maintaining the stream. Short circuit is the interruption of the flow, because a high resistance impeaches the flood. This concept is applied to electrical and cardiovascular physiology, as well as to the metabolic pathways.

  9. A wireless monitoring system for Hydrocephalus shunts.

    PubMed

    Narayanaswamy, A; Nourani, M; Tamil, L; Bianco, S

    2015-08-01

    Patients with Hydrocephalus are usually treated by diverting the excess Cerebrospinal Fluid (CSF) to other parts of the body using shunts. More than 40 percentage of shunts implanted fail within the first two years. Obstruction in the shunts is one of the major causes of failure (45 percent) and the detection of obstruction reduces the complexity of the revision surgery. This paper describes a proposed wireless monitoring system for clog detection and flow measurement in shunts. A prototype was built using multiple pressure sensors along the shunt catheters for sensing the location of clog and flow rate. Regular monitoring of flow rates can be used to adjust the valve in the shunt to prevent over drainage or under drainage of CSF. The accuracy of the flow measurement is more than 90 percent.

  10. Chemoembolic Hepatopulmonary Shunt Reduction to Allow Safe Yttrium-90 Radioembolization Lobectomy of Hepatocellular Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaba, Ron C., E-mail: rgaba@uic.edu; VanMiddlesworth, Kyle A.

    2012-12-15

    Yttrium-90 ({sup 90}Y) radioembolization represents an emerging transcatheter treatment option for the management of hepatocellular carcinoma (HCC). Elevation of the hepatopulmonary shunt fraction risks nontarget radiation to the lungs and may limit the use of {sup 90}Y therapy in patients with locally advanced disease with vascular invasion, who often demonstrate increased shunting. We present two cases in which patients with HCC and portal vein invasion resulting in elevated hepatopulmonary shunt fractions underwent chemoembolic shunt closure to allow safe {sup 90}Y radioembolization. Both patients demonstrated excellent tumor response and patient survival. On this basis, we propose a role for chemoembolic reductionmore » of the lung shunt fraction before {sup 90}Y radioembolization in patients with extensive tumor-related hepatopulmonary shunting.« less

  11. Research of vibration control based on current mode piezoelectric shunt damping circuit

    NASA Astrophysics Data System (ADS)

    Liu, Weiwei; Mao, Qibo

    2017-12-01

    The piezoelectric shunt damping circuit using current mode approach is imposed to control the vibration of a cantilever beam. Firstly, the simulated inductance with large values are designed for the corresponding RL series shunt circuits. Moreover, with an example of cantilever beam, the second natural frequency of the beam is targeted to control for experiment. By adjusting the values of the equivalent inductance and equivalent resistance of the shunt circuit, the optimal damping of the shunt circuit is obtained. Meanwhile, the designed piezoelectric shunt damping circuit stability is experimental verified. Experimental results show that the proposed piezoelectric shunt damping circuit based on current mode circuit has good vibration control performance. However, the control performance will be reduced if equivalent inductance and equivalent resistance values deviate from optimal values.

  12. Ascending transaqueductal cystoventriculoperitoneal shunting in Dandy-Walker malformation: technical note.

    PubMed

    Unal, Omer Faruk; Aras, Yavuz; Aydoseli, Aydin; Akcakaya, Mehmet Osman

    2012-01-01

    The optimal treatment for Dandy-Walker malformation is still controversial. Ventriculoperitoneal shunting, cystoperitoneal shunting or combinations are the most common surgical options in the management of this clinical entity. Endoscopic procedures like ventriculocystostomy, 3rd ventriculostomy or endoscopy-assisted shunt surgeries have become the focus of recent publications. We describe a new transcystic endoscopic technique, with the usage of a single ascending transaqueductal shunt catheter with additional holes, whereby both the posterior fossa cyst and supratentorial ventricular compartments are drained effectively. By using this new technique complications associated with combined shunting can be avoided. In addition, by equalizing the pressure within the supra- and infratentorial compartments, the upward or downward herniations associated with single-catheter shunting can be prevented. Copyright © 2013 S. Karger AG, Basel.

  13. Persistent hydrocephalus due to postural activation of a ventricular shunt anti-gravity device.

    PubMed

    Craven, Claudia L; Toma, Ahmed K; Watkins, Laurence D

    2017-03-01

    The ever present need to balance over drainage with under drainage in hydrocephalus has required innovations including adjustable valves with antigravity devices. These are activated in the vertical position to prevent siphoning. We describe a group of bedridden patients who presented with unexplained under drainage caused by activation of antigravity shunt components produced by peculiar head/body position. Retrospective single centre case series of hydrocephalus patients, treated with ventriculo-peritoneal (VP) shunt insertion between April 2014 - February 2016. These patients presented with clinical and radiological under drainage syndrome. Medical notes were reviewed for clinical picture and outcome. Radiological studies were reviewed assessing shunt placement and ventricular size. Seven patients presented with clinical and radiological under drainage syndrome. A consistent posturing of long term hyper-flexion of the neck whilst lying supine was observed. All patients had similar shunt construct (adjustable Miethke ProGAV valve and shunt assistant anti-gravity component). In each of those patients a hypothesis was formulated that neck flexion was activating the shunt assistance anti-gravity component in supine position. Five patients underwent shunt revision surgery removing the shunt assistant device from the cranium and adding an anti-gravity component to the shunt system at the chest. One had the shunt assistant completely removed and one patient was managed conservatively with mobilisation. All patients had clinical and radiological improvement. Antigravity shunt components implanted cranially in bedridden hydrocephalus patients will produce underdrainage due to head flexion induced anti-gravity device activation. In these patients, anti-gravity devices should be placed at the chest. Alternatively, special nursing attention should be paid to head-trunk angle. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Two signs indicative of successful access in nuclear medicine cerebrospinal fluid diversionary shunt studies.

    PubMed

    Bermo, Mohammed S; Khalatbari, Hedieh; Parisi, Marguerite T

    2018-05-08

    Successful shunt access is the first step in a properly performed nuclear medicine cerebrospinal fluid (CSF) shunt study. To determine the significance of the radiotracer configuration at the injection site during initial nuclear medicine CSF shunt imaging and the lack of early systemic radiotracer activity as predictors of successful shunt access. With Institutional Review Board approval, three nuclear medicine physicians performed a retrospective review of all consecutive CSF shunt studies performed in children at our institution in 2015. Antecedent nuclear medicine CSF shunt studies in these patients were also assessed and included in the review. The appearance of the reservoir site immediately after radiotracer injection was classified as either figure-of-eight or round/ovoid configuration. The presence or absence of early systemic distribution of the tracer on the 5-min static images was noted and separately evaluated. A total of 98 nuclear medicine ventriculoperitoneal CSF shunt studies were evaluated. Figure-of-eight configuration was identified in 87% of studies and, when present, had 93% sensitivity, 78% specificity, 92% accuracy, 98% positive predictive value (PPV) and 54% negative predictive value (NPV) as a predictor of successful shunt access. Early systemic activity was absent in 89 of 98 studies. Lack of early systemic distribution of the radiotracer had 98% sensitivity, 78% specificity, 96% accuracy, 98% PPV and 78% NPV as a predictor of successful shunt access. Figure-of-eight configuration in conjunction with the absence of early systemic tracer activity had 99% PPV for successful shunt access. Figure-of-eight configuration at the injection site or lack of early systemic radiotracer activity had moderate specificity for successful shunt access. Specificity and PPV significantly improved when both signs were combined in assessment.

  15. Right-to-left shunt detection sensitivity with air-saline and air-succinil gelatin transcranial Doppler.

    PubMed

    Puledda, Francesca; Toscano, Massimiliano; Pieroni, Alessio; Veneroso, Gabriele; Di Piero, Vittorio; Vicenzini, Edoardo

    2016-02-01

    Air-saline transcranial Doppler is nowadays the first-choice examination to identify right-to-left shunt. To increase right-to-left shunt detection in echocardiography, cardiologists also use air-gelatin mixtures, which are more stable, more echogenic, and easier to be prepared. We assessed the sensitivity of air-gelatin compared with air-saline for transcranial Doppler right-to-left shunt detection. Air-saline transcranial Doppler, during unilateral middle cerebral artery monitoring at rest and after Valsalva maneuver, was performed in patients referred to our neurosonology laboratory for right-to-left shunt detection. The same transcranial Doppler protocol was repeated with air-gelatin. To consider transcranial Doppler positive for cardiac right-to-left shunt, at least one embolic signal had to be detected within 20″ from contrast injection. Later signals were interpreted of pulmonary origin. Trans-thoracic echocardiography was repeated with both air-saline and air-gelatin. A total of 97 patients were enrolled; 46 had negative transcranial Doppler for cardiac right-to-left shunt with both air-saline and air-gelatin; out of these, four patients with air-saline plus two more patients with air-gelatin presented late, isolated microemboli, slightly more numerous with air-gelatin: these were interpreted as pulmonary shunts and confirmed with trans-thoracic echocardiography. In 28 patients with already early positive air-saline transcranial Doppler at rest, air-gelatin induced a marked right-to-left shunt increase, facilitating its visualization at trans-thoracic echocardiography. In 23 patients in whom air-saline transcranial Doppler was negative at rest and positive for cardiac right-to-left shunt only after Valsalva maneuver, air-gelatin was able to reveal shunt also at rest. Air-gelatin increases right-to-left shunt detection sensitivity with transcranial Doppler in particular at rest, even in patients in whom air-saline mixture fails to identify the shunt. The choice of air-gelatin mixture should be considered for multicentric, clinical, and research trials. © 2016 World Stroke Organization.

  16. A rare congenital extrahepatic portosystemic shunt affecting the inferior mesenteric vein, inferior vena cava, and left ovarian vein.

    PubMed

    Takeuchi, Hajime; Takeda, Yoko; Takahashi, Miyo; Hayashi, Shogo; Fukuzawa, Yoshitaka; Nakano, Takashi

    2014-09-01

    To observe a case of congenital extrahepatic portosystemic shunt and discuss it from the embryological and clinical viewpoints. An 85-year-old female cadaver was employed for a dissection course at Aichi Medical University in 2009. There was no evidence of liver cirrhosis macroscopically or microscopically. A portosystemic shunt was observed that involved communication between the inferior mesenteric vein, inferior vena cava (IVC), and left ovarian vein by a single Y-shaped shunt vessel. To the best of our knowledge, this is the first reported case of the above-mentioned three veins being connected by a single Y-shaped shunt vessel. Considering the other venous diameters, the shunt appeared to flow into the splenic vein and IVC. It cannot be denied that this shunt may have led to hepatic encephalopathy, although the shunt effect may have been minimal. Embryological development of IVC appears to occur close to the plexus of anastomosing vitelline veins, forming the portal vein.

  17. Successful embolization using interlocking detachable coils for a congenital extrahepatic portosystemic venous shunt in a child.

    PubMed

    Yamagami, Takuji; Yoshimatsu, Rika; Matsumoto, Tomohiro; Terayama, Koshi; Nishiumra, Akira; Maeda, Yousuke; Nishimura, Tsunehiko

    2007-11-01

    The authors report the case of a 6-year-old boy with a congenital extrahepatic portosystemic venous shunt. He had hyperammonemia. The shunt was 18 mm in diameter and located between the inferior mesenteric vein and the left internal iliac vein. The flow in the shunt was very rapid. After decreasing blood flow by inflating a balloon catheter inserted into the left internal iliac vein from the femoral vein, a microcatheter was coaxially advanced to the shunt to embolize the shunt. Embolization was successfully performed with interlocking detachable coils and microcoils without any complication. This patient's hyperammonemia resolved soon after the procedure.

  18. Design and simulation of RF MEMS SPST shunt and SPDT shunt-shunt switches for X-band and Ku-band applications

    NASA Astrophysics Data System (ADS)

    Lenka, Manas K.; Sharma, Amit; Sharma, Jaibir; DasGupta, Amitava

    2012-10-01

    This paper describes the design and simulation of RF MEMS SPST shunt and SPDT shunt-shunt switches with modified coplanar waveguide (CPW) configuration for X-band and Ku-band applications exhibiting high isolation and low insertion loss. By modifying the basic CPW structure for a six-strip membrane having length 720 μm, the resonant frequency can be reduced from 33.5 GHz to 13.5 GHz with isolation as high as -30 dB(-63 dB at resonant frequency) in Ku-band. Similar results are also found in case SPST and SPDT switches with other membrane types.

  19. Ventriculoperitoneal Shunt Fracture Following Application of Halo-Gravity Traction: A Case Report.

    PubMed

    Blakeney, William G; D'Amato, Charles

    2015-09-01

    Ventriculoperitoneal (VP) shunt malfunctions are very common, and shunt fracture is one of the most common causes. Shunt fractures are often a result of calcification and tethering, which predispose the tubing to fracture when mechanical stresses are applied. This case report describes a case of shunt fracture following application of halo-gravity traction for correction of spinal deformity. Chart and imaging data for a single case were reviewed and reported in this retrospective case study. A 10-year-old female, being treated for syndromic scoliosis, underwent posterior surgical release and application of halo-gravity traction. Increasing weight of traction was applied over a period of 6 weeks, for gradual deformity correction. It was noted on the 6-week cervical spine radiograph that the VP shunt had fractured at the base of the neck. The patient was taken to the operating room and intraoperative findings confirmed shunt fracture. This was repaired without complications. This case, to our best knowledge, is the first reported occurrence of shunt fracture following application of halo-gravity traction. It demonstrates the importance of careful monitoring of patients with VP shunts, when they are undergoing traction for correction of spinal deformity. Level IV.

  20. Single-Session Percutaneous Endovascular Mesocaval Shunt Creation and Balloon-Occluded Retrograde Transvenous Obliteration for the Treatment of Gastric Varices.

    PubMed

    Srinivasa, Ravi Nara; Majdalany, Bill S; Chick, Jeffrey Forris Beecham; Meadows, J Matthew; Fenlon, Jordan Bruce; Brewerton, Charles; Saad, Wael E

    2018-01-01

    In the setting of portal hypertension, the body responds by creating portosystemic venous shunts, which may lead to the development of varices. Endoscopic treatment of these varices is often warranted to prevent catastrophic bleeding. During the course of variceal treatment, 1 or more portosystemic shunts may be sacrificed, which may acutely exacerbate portal hypertension and reduce systemic venous return. This report describes percutaneous creation of a mesocaval shunt and balloon-occluded retrograde transvenous obliteration (BRTO) in a patient with cavernous transformation of the portal vein. The patient had previously undergone an unsuccessful attempt at transjugular intrahepatic portosystemic shunt (TIPS) creation with postoperative bleeding requiring splenectomy. As TIPS was not feasible, creation of a percutaneous mesocaval shunt provided an alternate pathway for portosystemic decompression, facilitating safe treatment of gastric varices with BRTO via a gastrorenal shunt. These procedures were performed simultaneously to reduce the risk of variceal bleeding from acute changes in portal venous pressures and redirect blood flow through the shunt to maintain patency. This is the first reported case of combined mesocaval shunt placement and BRTO in a single session. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Interventional embolization of congenital intrahepatic shunts in children.

    PubMed

    Wu, Lin; Zhao, Lu; Lu, Ying; He, Lan; Hu, Xihong

    2016-04-01

    Congenital intrahepatic shunts in children are rare and precise treatment strategies have not been established. The purpose of this study was to present our experience with transcatheter embolization in a descriptive case series of congenital intrahepatic shunts in children. We retrospectively studied 10 children with symptomatic congenital intrahepatic shunts who were treated with embolization at our institute between January 2008 and December 2014. Seven children had arteriovenous shunts in association with hepatic hemangiomas, two had arterioportal shunts and one had portosystemic shunts. The major presentations were congestive heart failure and severe anemia in the groups with arteriovenous and arterioportal shunts, respectively. Following embolization, two children died in the arteriovenous group, one from progressive liver dysfunction and the other from abdominal compartment syndrome. One child in the arterioportal group required liver transplantation after initial embolization. With mean post-procedure follow-up of 15 months (range 4-54 months), all the remaining children were well, with resolution of the symptoms. Interventional embolization provides an alternative to surgical ligation or hepatic resection in children with clinically significant intrahepatic shunts. For lesions with complex morphology, embolization may be inadequate and liver transplantation might be the only therapeutic option.

  2. Prediction of Susceptibility to Acute Mountain Sickness Using Hypoxia-Induced Intrapulmonary Arteriovenous Shunt and Intracardiac Shunt Fractions

    DTIC Science & Technology

    2013-10-01

    echocardiography to determine bubble/shunt scores. We will also use nuclear medicine imaging to determine shunt fractions following acute exposures to... echocardiography while breathing hypoxic gas mixtures. – TASK COMPLETED. For Task #1.3 “Quantify shunt during hypoxic exposure with SPECT CT – PFO...subjects.” 19 PFO+ subjects have completed saline contrast echocardiography while breathing hypoxic gas mixtures for 30 min. One PFO+ subject that had

  3. Treatment of Portosystemic Shunt Myelopathy with a Stent Graft Deployed through a Transjugular Intrahepatic Route

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jain, Deepak, E-mail: deepakjain02@yahoo.com; Arora, Ankur, E-mail: aroradrankur@yahoo.com; Deka, Pranjal, E-mail: drpranjaldeka@gmail.com

    2013-08-01

    A case of surgically created splenorenal shunt complicated with shunt myelopathy was successfully managed by placement of a stent graft within the splenic vein to close the portosystemic shunt and alleviate myelopathy. To our knowledge, this is the first report of a case of shunt myelopathy in a patient with noncirrhotic portal fibrosis without cirrhosis treated by a novel technique wherein a transjugular intrahepatic route was adopted to deploy the stent graft.

  4. Morphology of congenital portosystemic shunts involving the right gastric vein in dogs.

    PubMed

    White, R N; Parry, A T

    2015-07-01

    To describe the anatomy of congenital portosystemic shunts involving the right gastric vein in dogs. Retrospective review of a consecutive series of dogs managed for congenital portosystemic shunt. Twenty-two dogs met the inclusion criteria of a congenital portosystemic shunt involving the right gastric vein with recorded intraoperative mesenteric portovenography or computed tomography angiography and gross observations at the time of surgery. Of these, 20 (91%) had a shunt that entered the pre-hepatic caudal vena cava at the level of the epiploic foramen and two (9%) had a shunt that entered the post-hepatic caudal vena cava at the level of the diaphragm. Shunts entering the pre-hepatic caudal vena cava could be further classified into three consistent subdivisions. The morphology of each shunt type described appeared to be a result of an abnormal communication between the left gastric vein and the caudal vena cava, the presence or absence of an abnormal communication between the splenic, left gastric and portal veins and the subsequent development of preferential blood flow through essentially normal portal vessels within the portal venous system. The abnormal communication (shunt) was through the left gastric vein and not the right gastric vein, as might have been expected. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2015 British Small Animal Veterinary Association.

  5. Haematology and coagulation profiles in cats with congenital portosystemic shunts.

    PubMed

    Tzounos, Caitlin E; Tivers, Michael S; Adamantos, Sophie E; English, Kate; Rees, Alan L; Lipscomb, Vicky J

    2017-12-01

    Objectives The objectives of this study were, first, to report the haematological parameters and coagulation times for cats with a congenital portosystemic shunt (CPSS) and the influence of surgical shunt attenuation on these parameters; and, second, to identify any association between prolongation in coagulation profiles and incidence of perioperative haemorrhage. Methods This was a retrospective clinical study using client-owned cats with a CPSS. Signalment, shunt type (extra- or intrahepatic), degree of shunt attenuation (complete or partial), haematological parameters, prothrombin time (PT) and activated partial thromboplastin time (aPTT) test results, and occurrence of any perioperative clinical bleeding complications were recorded for cats undergoing surgical treatment of a CPSS at the Royal Veterinary College, UK, between 1994 and 2011. Results Forty-two cats were included. Thirty-six (85.7%) had an extrahepatic CPSS and six (14.3%) had an intrahepatic CPSS. Preoperatively, mean cell volume (MCV) and mean cell haemoglobin (MCH) were below the reference interval (RI) in 32 (76.2%) and 31 (73.8%) cats, respectively. Red blood cell count and mean cell haemoglobin concentration (MCHC) were above the RI in 10 (23.8%) and eight (19.1%) cats, respectively. Postoperatively, there were significant increases in haematocrit ( P = 0.044), MCV ( P = 0.008) and MCH ( P = 0.002). Despite the significant increase in MCV postoperatively, the median MCV postoperatively was below the RI, indicating persistence of microcytosis. Preoperatively, PT was above the upper RI in 14 cats (87.5%), and aPTT was above the upper RI in 11 cats (68.8%). No cat demonstrated a perioperative clinical bleeding complication. Conclusions and relevance Cats with a CPSS are likely to present with a microcytosis, but rarely present with anaemia, leukocytosis or thrombocytopenia. Surgical attenuation of the CPSS results in a significant increase in the HCT and MCV. Coagulation profiles in cats with a CPSS are likely to be prolonged, irrespective of shunt type, but do not appear to be associated with an increased risk of clinical bleeding.

  6. Parent/guardian knowledge regarding implanted shunt type, setting, and symptoms of malfunction/infection.

    PubMed

    Ackerman, Laurie L; Fulkerson, Daniel H; Jea, Andrew; Smith, Jodi L

    2018-04-01

    OBJECTIVE Patients with shunts often interact with providers distant from their primary hospital, making it important that the parent(s)/guardian(s) is well versed in the type of shunt implanted and symptoms of malfunction/infection. This is particularly important with magnetic-sensitive programmable valves, as the use of MRI becomes more prevalent. METHODS Over a 6-month period, primary caregivers of 148 consecutive patients who received shunts were prospectively administered questionnaires at clinic visits. Caregivers were asked to do the following: 1) identify shunt valve name, type, and setting if applicable; 2) list symptoms of shunt malfunction/infection; and 3) indicate whether they had access to references regarding shunt type/setting, booklets from the Hydrocephalus Association, and quick reference cards with symptoms of shunt malfunction/infection. One cohort of caregivers (n = 75) was asked to carry informational cards with shunt valve/setting information (group I); this cohort was compared with another subgroup of caregivers (n = 73) not carrying cards (group II). RESULTS The mean (± SD) age of patients at implantation/revision was 3.71 ± 4.91 years, and the age at follow-up was 6.12 ± 5.4 years. The average time from surgery to administration of the questionnaire was 2.38 ± 3.22 years. There were 86 new shunt insertions and 62 revisions. One hundred twenty-eight caregivers (87%) could identify the type of valve (programmable vs nonprogrammable). On the other hand, only 72 caregivers (49%) could identify the valve name. Fifty-four of 73 (74%) caregivers of patients who had shunts with programmable valves could correctly identify the valve setting. One hundred caregivers (68%) had a copy of the Hydrocephalus Association booklet, and 103 (70%) had quick reference cards. Eighty caregivers (54%) had references on shunt type/setting. Most caregivers (127 [86%]) could name ≥ 3 signs/symptoms of shunt malfunction, with vomiting (61%), headache (49%), and sleeps more/lethargic (35%) most frequently reported. Caregivers of patients in group I were more likely to have cards with symptoms of shunt infection or malfunction (p = 0.015); have information cards regarding shunt type/setting (p < 0.001); and correctly identify valve type (p = 0.001), name (p < 0.001), and setting if programmable (p = 0.0016). There were no differences in ability to list symptoms of shunt malfunction or infection (p = 0.8812) or in access to Hydrocephalus Association booklets (p = 0.1288). There were no significant demographic differences between the groups, except that group I patients had a shorter time from surgery to last follow-up (1.66 vs 3.17 years; p = 0.0001). CONCLUSIONS Education regarding the care of patients with shunts by providing written cards with shunt type/setting and access to reference materials seems to be effective. Developing plans for guided instruction with assessment in the clinic setting of a caregiver's knowledge is important for patient safety.

  7. Right-to-left shunt may be prone to affect the white matter integrity of posterior circulation in migraine without aura.

    PubMed

    Xie, Hui; Bian, Yitong; Jian, Zhijie; Huo, Kang; Liu, Rui; Zhu, Dan; Zhang, Lihui; Wu, Jun; Yang, Jian; Liu, Jixin; Luo, Guogang

    2018-01-01

    Numerous studies have indicated an association between migraine and right-to-left shunt. However, little is known about whether right-to-left shunt has an effect on the migraine brain. This observational study aims to explore the impact of right-to-left shunt on the brain of migraine without aura on microstructural level. Thirty-five patients with migraine without aura were enrolled in this study. Contrast-enhanced Transcranial Doppler was performed to evaluate the status of right-to-left shunt. Three-dimensional T1-weighted and diffusion tensor images were acquired for data analysis. We employed voxel-based morphometry and tract-based spatial statistical analyses to assess the differences of gray and white matter between migraineurs with and without right-to-left shunt, respectively. Among the 35 patients, 19 (54.3%) patients had right-to-left shunt. There were no significant differences in headache features between migraineurs with and without right-to-left shunt. There were significant increases of mean and radial diffusivity in migraineurs with right-to-left shunt compared with migraineurs without right-to-left shunt. The alterations were primarily located in the right posterior thalamic radiation, secondly in the body of corpus callosum and the right superior corona radiata. No significant differences were observed in values of fractional anisotropy and axial diffusivity. No significant between-group differences were found in gray matter volume. Right-to-left shunt may cause alterations of white matter integrity in migraine without aura, and the alterations are more likely to be located at the posterior circulation.

  8. Congenital portosystemic shunts: prenatal manifestations with postnatal confirmation and follow-up.

    PubMed

    Han, Byoung Hee; Park, Sung Bin; Song, Mi Jin; Lee, Kyung Sang; Lee, Young-Ho; Ko, Sun Young; Lee, Yeon Kyung

    2013-01-01

    The purpose of this study was to evaluate prenatal sonographic findings that could be helpful for diagnosis of congenital intrahepatic portosystemic venous shunts and the follow-up results. Six neonates with congenital shunts between the portal vein and hepatic vein were enrolled in this study. Prenatal sonography was performed in 5 cases. We categorized the cases according to a previously published classification of intrahepatic portosystemic venous shunts and retrospectively reviewed the prenatal and postnatal sonographic examinations to identify findings that might be helpful for diagnosing shunts prenatally. Follow-up sonographic examinations were done until closure of the shunts. Clinical features were also determined. According to the original reports, intrahepatic portosystemic venous shunts were diagnosed by prenatal sonography in 2 of 5 cases. In the remaining 3 cases, there were suggestive abnormal findings on retrospective review, including an abnormal intrahepatic tubular structure, a prominent hepatic vein, and congestive heart failure. Postnatal sonography showed type 2 shunts in all 6 cases. In 1 case, there were 2 type 2 lesions between two branches of the left portal vein and the middle and left hepatic veins. On follow-up sonography, 5 of the 6 congenital shunts had spontaneously closed by 11 months of age. One case was treated with coil embolization during the neonatal period. Intrauterine growth restriction was the most commonly clinical feature prenatally. Findings such as an abnormal tubular structure, a prominent hepatic vein, and congestive heart failure can be important clues for identifying congenital intrahepatic portosystemic venous shunts on prenatal sonography. The use of prenatal and postnatal sonography is feasible for detection and evaluation of these shunts.

  9. Use of intraoperative venography to guide the distal portion of a ventriculoatrial shunt past an obstruction in the central veins: technical case report.

    PubMed

    Momin, Eric N; Recinos, Pablo F; Coon, Alexander L; Rigamonti, Daniele

    2010-06-01

    Ventriculoatrial (VA) shunting is commonly used to treat hydrocephalus when ventriculoperitoneal shunting has failed. Placement of a VA shunt in patients with narrowing or occlusion of the central veins presents considerable difficulty because few imaging modalities exist to safely and reliably insert a guidewire or atrial catheter past the occlusion. We report the use of intraoperative venography to guide the placement of the distal portion of a VA shunt in a patient with a valve blocking the left brachiocephalic vein. A 42-year-old man with pseudotumor cerebri and a left ventriculoperitoneal shunt presented with severe headaches. He was diagnosed with partial distal shunt obstruction. Because of a history of failed attempts at ventriculoperitoneal shunting, conversion to a VA shunt via the left internal jugular vein was planned. Surgery was performed by using the standard technique until resistance was encountered when inserting a guidewire into the internal jugular vein. Intraoperative venography of the central veins was performed, which showed a large valve blocking progression of the guidewire in the left brachiocephalic vein. Using fluoroscopic guidance, a 0.035-inch guidewire was successfully directed through the vein past the obstruction and exchanged for a peel-away introducer. The distal shunt catheter was then inserted, and the correct position in the atrium was confirmed fluoroscopically. When obstruction of the central veins is found during a VA shunting procedure, intraoperative venography is a useful method to aid in the placement of the atrial catheter through the central veins.

  10. The Electrophysiologic Effects of Acute Mitral Regurgitation in a Canine Model.

    PubMed

    Lawrance, Christopher P; Henn, Matthew C; Miller, Jacob R; Kopek, Michael A; Zhang, Andrew J; Schuessler, Richard B; Damiano, Ralph J

    2017-04-01

    Atrial fibrillation (AF) occurs in 30% of patients with mitral regurgitation referred for surgical intervention. However, the underlying mechanisms in this population are poorly understood. This study examined the effects of acute left atrial volume overload on atrial electrophysiology and the inducibility of AF. Ten canines underwent insertion of an atrioventricular shunt between the left ventricle and left atrium. Shunt and aortic flows were calculated, and the shunt was titrated to a shunt fraction to 40% to 50% of cardiac output. An epicardial plaque with 250 bipolar electrodes was used to determine activation and refractory periods. Biatrial pressures and volumes, conduction times, and atrial fibrillation inducibility were recorded. Data were collected at baseline and 20 minutes after shunt opening and closure. Mean shunt flow was 1.3 ± 0.5 L/min with a shunt fraction of 43% ± 6% simulating moderate to severe mitral regurgitation. Compared with baseline, left atrial volumes and maximum pressures increased by 27% and 29%, respectively, after shunt opening. Biatrial effective refractory periods did not change significantly after shunt opening or closure. Conduction times increased by 9% with shunt opening and returned to baseline after closure. AF duration or inducibility did not change with shunt opening. This canine model of mitral regurgitation demonstrated that acute left atrial volume overload did not increase the inducibility of atrial arrhythmias in contrast with experimental and clinical findings of chronic left atrial volume overload. This suggests that the substrates for AF in patients with mitral regurgitation are a result of chronic remodeling. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. A rare and important case of Staphylococcus haemolyticus-associated ventricular atrial shunt nephritis.

    PubMed

    Suen, Kyle; Mashhadian, Ardavan; Figarsky, Ian; Payumo, Jeff; Liu, Antonio

    2017-12-01

    Shunt nephritis is a rare and relatively new diagnosis involving glomerular kidney damage following ventriculoperitoneal and ventriculoatrial shunt placement. Our case report summarizes the presentation, diagnostic workup, and management of a patient with shunt nephritis. We also review and discuss the current literature on the topic.

  12. Cardiovascular magnetic resonance of cardiac function and myocardial mass in preterm infants: a preliminary study of the impact of patent ductus arteriosus

    PubMed Central

    2014-01-01

    Background Many pathologies seen in the preterm population are associated with abnormal blood supply, yet robust evaluation of preterm cardiac function is scarce and consequently normative ranges in this population are limited. The aim of this study was to quantify and validate left ventricular dimension and function in preterm infants using cardiovascular magnetic resonance (CMR). An initial investigation of the impact of the common congenital defect patent ductus arteriosus (PDA) was then carried out. Methods Steady State Free Procession short axis stacks were acquired. Normative ranges of left ventricular end diastolic volume (EDV), stroke volume (SV), left ventricular output (LVO), ejection fraction (EF), left ventricular (LV) mass, wall thickness and fractional thickening were determined in “healthy” (control) neonates. Left ventricular parameters were then investigated in PDA infants. Unpaired student t-tests compared the 2 groups. Multiple linear regression analysis assessed impact of shunt volume in PDA infants, p-value ≤ 0.05 being significant. Results 29 control infants median (range) corrected gestational age at scan 34+6(31+1-39+3) weeks were scanned. EDV, SV, LVO, LV mass normalized by weight and EF were shown to decrease with increasing corrected gestational age (cGA) in controls. In 16 PDA infants (cGA 30+3(27+3-36+1) weeks) left ventricular dimension and output were significantly increased, yet there was no significant difference in ejection fraction and fractional thickening between the two groups. A significant association between shunt volume and increased left ventricular mass correcting for postnatal age and corrected gestational age existed. Conclusion CMR assessment of left ventricular function has been validated in neonates, providing more robust normative ranges of left ventricular dimension and function in this population. Initial investigation of PDA infants would suggest that function is relatively maintained. PMID:25160730

  13. Hepatic encephalopathy in a liver transplant recipient with stable liver function.

    PubMed

    Arab, Juan Pablo; Meneses, Luis; Pérez, Rosa M; Arrese, Marco; Benítez, Carlos

    2013-04-01

    Postshunt hepatic encephalopathy after liver transplantation (LT) is an infrequent condition and is commonly associated with portal occlusion or stenosis and the presence of a patent portosystemic shunt. Portal vein stenosis (PVS) or thrombosis (PVT) are uncommon complications after LT. The overall frequency of both complications is reported to be less than 3%. When PVS or PVT develop early after LT, the occlusion of the portal vein can have catastrophic consequences to the graft including acute liver failure and graft loss. Late PVT/PVS are asymptomatic in approximately 50% of the cases and mainly diagnosed by a routine ultrasound. Symptomatic postshunt hepatic encephalopathy (HE) is a very infrequent condition after LT that has been scarcely reported in the literature. We present here the case of a liver recipient with normal graft function who presented with hepatic encephalopathy 3 months after LT with stable liver function but a severe portal stenosis and the presence of a spontaneous portosystemic shunt whose successful endovascular treatment was followed by the complete resolution of the HE.

  14. First 60 fetal in-utero myelomeningocele repairs at Saint Louis Fetal Care Institute in the post-MOMS trial era: hydrocephalus treatment outcomes (endoscopic third ventriculostomy versus ventriculo-peritoneal shunt).

    PubMed

    Elbabaa, Samer K; Gildehaus, Anne M; Pierson, Matthew J; Albers, J Andrew; Vlastos, Emanuel J

    2017-07-01

    The published results of the Management of Myelomeningocele Study (MOMS) trial in 2011 showed improved outcomes (reduced need for shunting, decreased incidence of Chiari II malformation, and improved scores of mental development and motor function) in the fetal prenatal repair group compared to the postnatal group. Historically, endoscopic third ventriculostomy (ETV) remains as a controversial hydrocephalus treatment option with high failure rates in pediatric patients with a history of myelomeningocele (MMC). We report hydrocephalus treatment outcomes in the fetal in-utero myelomeningocele repair patients who underwent repair at our Saint Louis Fetal Care Institute following the MOMS trial. We looked carefully at ETV outcomes in this patient population and we identified risk factors for failure. At our Saint Louis Fetal Care Institute, we followed the maternal and fetal inclusion and exclusion criteria used by the MOMS trial. The records of our first 60 fetal MMC repairs performed at our institute between 2011 and 2017 were examined. We retrospectively reviewed the charts, prenatal fetal magnetic resonance imaging (MRI) and ultrasound (US) imaging findings, postnatal brain MRI, and Bayley neurodevelopment testing results for infants and children who underwent surgical treatment of symptomatic hydrocephalus (VP shunt versus ETV). Multiple variables possibly related to ETV failure were considered for identifying risk factors for ETV failure. Between May 2011 and March 2017, 60 pregnant female patients underwent the prenatal MMC repair for their fetuses between 20 and 26 weeks' gestational age (GA) utilizing the standard hysterotomy for exposure of the fetus, and microsurgical repair of the MMC defect. All MMC defects underwent successful in-utero repair, with subsequent progression of the pregnancy. At the time of this study, 58 babies have been born, 56 are alive since there were 2 mortalities in the neonatal period due to prematurity. One patient was excluded given lack of consent for research purposes. From the remaining 55 patient included in this study, a total of 30 infants and toddlers underwent treatment of hydrocephalus (ETV and VPS groups). Twenty-five patients underwent ETV (24 primary ETV and 1 after shunt failure). Nineteen patients underwent shunt placements (6 primary/13 after ETV failure). Mean GA at time of MMC repair for the ETV group was 24 + 6/7 weeks (range 22 + 4/7 to 25 + 6/7). Mean follow up for patients who had a successful ETV was 17.25 months (range 4-57 months). Bayley neurodevelopmental testing results were examined pre- and post-ETV. Overall ETV success rate was 11/24 (45.8%) at the time of this study. The total number of patients who underwent shunt placement was 19/55 (34.5%), while shunting rate was 40% in the MOMS trial. Using a simple logistic regression analysis to identify predictors of ETV failure, ETV age ≤6 months and gestational age ≥23 weeks at repair of myelomeningocele were significant predictors for ETV failure while in-utero ventricular stability ≤4 mm and in-utero ventricular size post-repair ≤15.5 mm were significant predictors for ETV success. None of the listed variables independently predicted classification into ETV success versus ETV failure groups when entered into multiple logistic regression analysis. ETV, as an alternative to initial shunting, may continue to show promising results for treating fetal MMC repair patient population who present with symptomatic hydrocephalus during infancy and early childhood. Although our overall CSF diversion rate (ETV and VPS groups) in our fetal MMC group is higher than the MOMS trial, our shunting rate is lower given our higher incidence of patients with successful ETV. To our knowledge, this is the largest reported ETV series in patients who underwent fetal MMC repair. ETV deserves a closer look in the setting of improved hindbrain herniation in fetal in-utero MMC repair patients. In our series, young age (less than 6 months) and late GA at time of fetal MMC repair (after 23 weeks GA) were predictors for ETV failure, while in-utero stability of ventricular size (less than 4 mm) and in-utero ventricular size post-repair ≤15.5 mm were predictors for ETV success. Larger series and potential prospective randomized studies are required for further evaluation of risk factors for ETV failure in the fetal MMC patient population.

  15. Pediatric hydrocephalus: systematic literature review and evidence-based guidelines. Part 3: Endoscopic computer-assisted electromagnetic navigation and ultrasonography as technical adjuvants for shunt placement.

    PubMed

    Flannery, Ann Marie; Duhaime, Ann-Christine; Tamber, Mandeep S; Kemp, Joanna

    2014-11-01

    This systematic review was undertaken to answer the following question: Do technical adjuvants such as ventricular endoscopic placement, computer-assisted electromagnetic guidance, or ultrasound guidance improve ventricular shunt function and survival? The US National Library of Medicine PubMed/MEDLINE database and the Cochrane Database of Systematic Reviews were queried using MeSH headings and key words specifically chosen to identify published articles detailing the use of cerebrospinal fluid shunts for the treatment of pediatric hydrocephalus. Articles meeting specific criteria that had been delineated a priori were then examined, and data were abstracted and compiled in evidentiary tables. These data were then analyzed by the Pediatric Hydrocephalus Systematic Review and Evidence-Based Guidelines Task Force to consider evidence-based treatment recommendations. The search yielded 163 abstracts, which were screened for potential relevance to the application of technical adjuvants in shunt placement. Fourteen articles were selected for full-text review. One additional article was selected during a review of literature citations. Eight of these articles were included in the final recommendations concerning the use of endoscopy, ultrasonography, and electromagnetic image guidance during shunt placement, whereas the remaining articles were excluded due to poor evidence or lack of relevance. The evidence included 1 Class I, 1 Class II, and 6 Class III papers. An evidentiary table of relevant articles was created. CONCLUSIONS/RECOMMENDATION: There is insufficient evidence to recommend the use of endoscopic guidance for routine ventricular catheter placement. Level I, high degree of clinical certainty. The routine use of ultrasound-assisted catheter placement is an option. Level III, unclear clinical certainty. The routine use of computer-assisted electromagnetic (EM) navigation is an option. Level III, unclear clinical certainty.

  16. Predictors and outcomes of shunt-dependent hydrocephalus in patients with aneurysmal sub-arachnoid hemorrhage

    PubMed Central

    2012-01-01

    Background Hydrocephalus following spontaneous aneurysmal sub-arachnoid hemorrhage (SAH) is often associated with unfavorable outcome. This study aimed to determine the potential risk factors and outcomes of shunt-dependent hydrocephalus in aneurysmal SAH patients but without hydrocephalus upon arrival at the hospital. Methods One hundred and sixty-eight aneurysmal SAH patients were evaluated. Using functional scores, those without hydrocephalus upon arrival at the hospital were compared to those already with hydrocephalus on admission, those who developed it during hospitalization, and those who did not develop it throughout their hospital stay. The Glasgow Coma Score, modified Fisher SAH grade, and World Federation of Neurosurgical Societies grade were determined at the emergency room. Therapeutic outcomes immediately after discharge and 18 months after were assessed using the Glasgow Outcome Score. Results Hydrocephalus accounted for 61.9% (104/168) of all episodes, including 82 with initial hydrocephalus on admission and 22 with subsequent hydrocephalus. Both the presence of intra-ventricular hemorrhage on admission and post-operative intra-cerebral hemorrhage were independently associated with shunt-dependent hydrocephalus in patients without hydrocephalus on admission. After a minimum 1.5 years of follow-up, the mean Glasgow outcome score was 3.33 ± 1.40 for patients with shunt-dependent hydrocephalus and 4.21 ± 1.19 for those without. Conclusions The presence of intra-ventricular hemorrhage, lower mean Glasgow Coma Scale score, and higher mean scores of the modified Fisher SAH and World Federation of Neurosurgical grading on admission imply risk of shunt-dependent hydrocephalus in patients without initial hydrocephalus. These patients have worse short- and long-term outcomes and longer hospitalization. PMID:22765765

  17. Design and test hardware for a solar array switching unit

    NASA Technical Reports Server (NTRS)

    Patil, A. R.; Cho, B. H.; Sable, D.; Lee, F. C.

    1992-01-01

    This paper describes the control of a pulse width modulated (PWM) type sequential shunt switching unit (SSU) for spacecraft applications. It is found that the solar cell output capacitance has a significant impact on SSU design. Shorting of this cell capacitance by the PWM switch causes input current surges. These surges are minimized by the use of a series filter inductor. The system with a filter is analyzed for ripple and the control to output-voltage transfer function. Stable closed loop design considerations are discussed. The results are supported by modeling and measurements of loop gain and of closed-loop bus impedance on test hardware for NASA's 120 V Earth Observation System (EOS). The analysis and modeling are also applicable to NASA's 160 V Space Station power system.

  18. Patient data system for monitoring shunts.

    PubMed

    Frank, E; Su, E; Smith, K

    1988-01-01

    Rapidly locating accurate data on a patient's shunt system is often extremely difficult. We have developed a simple system to fill a perceived need for recording current data on a patients shunt. This system employs an easily updated record in the patient's hospital or clinic chart as well as a wallet-sized data card for the patient or his family to carry. The data in the chart include the configuration of the patient's current shunt system and a graphic record of previous shunt problems. The small patient data card describes the age of the shunt system and its current configuration. We have found that this system provides assistance in the routine follow-up of patients with shunts and plays an extremely necessary role in the emergency evaluation of these patients, particularly when an emergency evaluation is undertaken in facilities distant from the location of regular treatment.

  19. Sodium accumulation at potential-induced degradation shunted areas in polycrystalline silicon modules

    DOE PAGES

    Harvey, Steven P.; Aguiar, Jeffery A.; Hacke, Peter; ...

    2016-09-19

    Here, we investigated potential-induced degradation (PID) in silicon mini-modules that were subjected to accelerated stressing to induce PID conditions. Shunted areas on the cells were identified with photoluminescence and dark lock-in thermography (DLIT) imaging. The identical shunted areas were then analyzed via time-of-flight secondary-ion mass spectrometry (TOFSIMS) imaging, 3-D tomography, and high-resolution transmission electron microscopy. The TOF-SIMS imaging indicates a high concentration of sodium in the shunted areas, and 3-D tomography reveals that the sodium extends more than 2 um from the surface below shunted regions. Transmission electron microscopy investigation reveals that a stacking fault is present at an areamore » identified as shunted by DLIT imaging. After the removal of surface sodium, tomography reveals persistent sodium present around the junction depth of 300 nm and a drastic difference in sodium content at the junction when comparing shunted and nonshunted regions.« less

  20. Catheter interventional treatment of congenital portosystemic venous shunts in childhood.

    PubMed

    Knirsch, Walter; Benz, Dominik C; Bühr, Patrick; Quandt, Daniel; Weber, Roland; Kellenberger, Christian; Braegger, Christian P; Kretschmar, Oliver

    2016-06-01

    The study aimed on the catheter interventional treatment of congenital portosystemic venous shunt (CPSVS) in childhood and the impact on vascular growth of hypoplastic portal veins. Clinical course and follow up of partial or complete closure of CPSVS are described. CPSVS is a very rare vascular malformation of the portal venous drainage resulting in potentially life threatening abdominal, pulmonary, cerebral, and cardiac complications. The anatomic type, clinical course, and diagnosis must be determined for optimal management. Single centre case series. Eight (6 female) children with extrahepatic (n = 5) and intrahepatic (n = 3) CPSVS were diagnosed invasively by catheterization, including test balloon occlusion of the shunt and simultaneous retrograde angiography, and treated by catheter interventions (n = 5) with partial (n = 2) and complete (n = 3) occlusion of CPSVS at a median age of 3.9 years (range 0.7-21). Congenital heart disease (CHD) was the most frequent associated organ manifestation (n = 5) followed by mild to severe pulmonary arterial hypertension (n = 4), hepatopulmonary syndrome (n = 2), and portosystemic encephalopathy (n = 1). CHD was simple (n = 3) or complex type (n = 2). Three patients were untreated so far, because they were in excellent clinical condition at an age <1 year, refused treatment, or planned for later treatment. Accurate invasive diagnosis of CPSVS with test balloon occlusion of the shunt is mandatory to depict the anatomic situation. Catheter interventional treatment of CPSVS offers a feasible and safe approach with complete or partial closure of the vascular malformation inducing potentially significant vascular growth of a former hypoplastic portal venous system. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  1. Pharyngeal oxygen administration increases the time to serious desaturation at intubation in acute lung injury: an experimental study

    PubMed Central

    2010-01-01

    Introduction Endotracheal intubation in critically ill patients is associated with severe life-threatening complications in about 20%, mainly due to hypoxemia. We hypothesized that apneic oxygenation via a pharyngeal catheter during the endotracheal intubation procedure would prevent or increase the time to life-threatening hypoxemia and tested this hypothesis in an acute lung injury animal model. Methods Eight anesthetized piglets with collapse-prone lungs induced by lung lavage were ventilated with a fraction of inspired oxygen of 1.0 and a positive end-expiratory pressure of 5 cmH2O. The shunt fraction was calculated after obtaining arterial and mixed venous blood gases. The trachea was extubated, and in randomized order each animal received either 10 L oxygen per minute or no oxygen via a pharyngeal catheter, and the time to desaturation to pulse oximeter saturation (SpO2) 60% was measured. If SpO2 was maintained at over 60%, the experiment ended when 10 minutes had elapsed. Results Without pharyngeal oxygen, the animals desaturated after 103 (88-111) seconds (median and interquartile range), whereas with pharyngeal oxygen five animals had a SpO2 > 60% for the 10-minute experimental period, one animal desaturated after 7 minutes, and two animals desaturated within 90 seconds (P < 0.016, Wilcoxon signed rank test). The time to desaturation was related to shunt fraction (R2 = 0.81, P = 0.002, linear regression); the animals that desaturated within 90 seconds had shunt fractions >40%, whereas the others had shunt fractions <25%. Conclusions In this experimental acute lung injury model, pharyngeal oxygen administration markedly prolonged the time to severe desaturation during apnea, suggesting that this technique might be useful when intubating critically ill patients with acute respiratory failure. PMID:20497538

  2. 49 CFR 236.57 - Shunt and fouling wires.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Shunt and fouling wires. 236.57 Section 236.57...: All Systems Track Circuits § 236.57 Shunt and fouling wires. (a) Except as provided in paragraph (b) of this section, shunt wires and fouling wires hereafter installed or replaced shall consist of at...

  3. 49 CFR 236.57 - Shunt and fouling wires.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Shunt and fouling wires. 236.57 Section 236.57...: All Systems Track Circuits § 236.57 Shunt and fouling wires. (a) Except as provided in paragraph (b) of this section, shunt wires and fouling wires hereafter installed or replaced shall consist of at...

  4. Portosystemic shunts for extrahepatic portal hypertension in children.

    PubMed

    Tocornal, J; Cruz, F

    1981-07-01

    Twenty-three children with prehepatic portal hypertension and hemorrhage due to ruptured esophagogastric varices had portosystemic shunts. Their ages ranged from two years and seven months to 15 years. Eleven were less than eight years of age. Twenty patients had portal vein cavernomatosis and three patients had double portal veins. In 21 patients, a mesocaval type of shunt was done. A splenorenal shunt was performed in two. There was no surgical mortality. Two shunts occluded, both in rather young infants--two years and seven months and three years of age. In all the others, there was no further bleeding, and the shunts remained patent, as shown by abdominal angiograms. Neuropsychiatric disorders, probably due to hepatic encephalopathy, occurred in only one patient. On the basis of this favorable experience, we believe that an elective portosystemic shunt should, in general, be performed upon children with prehepatic portal hypertension after one major variceal hemorrhage. We favor a mesocaval type of shunt in these children because of the larger diameter of the vessels involved in the anastomosis and because it preserves the spleen, maintaining defense against subsequent infection.

  5. A novel method for passing cerebrospinal fluid shunt tubing: a proof of principle study.

    PubMed

    Tubbs, R Shane; Goodrich, Dylan; Tubbs, Isaiah; Loukas, Marios; Cohen-Gadol, Aaron A

    2014-12-01

    Few innovations in the method of tunneling shunt tubing for cerebrospinal fluid (CSF) shunt diversion have been made since this treatment of hydrocephalus was first developed. Therefore, this feasibility study was performed with the hope of identifying an improved technique that could potentially carry fewer complications. On 10 cadaver sides and when placed in the supine position, small skin incisions were made at the clavicle and ipsilateral subcostal region, and magnets were used to pass standard shunt tubing between the two incisions. Nickel-plated magnets were less effective in pulling the shunt tubing below the skin compared with ceramic magnets. Of these, magnets with pull strengths of 150-200 lbs were the most effective in dragging the subcutaneous tubing between the two incisions. No obvious damage to the skin from the overlying magnet was seen in any specimen. Few options exist for tunneling distal shunt tubing for CSF shunt procedures. Future patient studies are needed to determine if the technique described herein is superior to current methods, particularly when examining patient groups that are at a greater risk for injury during tunneling shunt catheters.

  6. Ventriculoperitoneal shunt infection in Haji Adam Malik Hospital, Medan

    NASA Astrophysics Data System (ADS)

    Dharmajaya, R.

    2018-03-01

    Installation of ventriculoperitoneal shunts (VP) represented a substantial progress in the neurosurgical management of hydrocephalus in children. However, infection is the most commonpostoperative complication of aventriculoperitoneal shunt. It is important because it is related to substantial morbidity and mortality, and exerts a negative impact on the quality of life of patients. We retrospectively analyzed all 20 cases of shunt infection from 2013 to 2016. The types of infections found were exposed shunts15 cases (75%), and 5 cases of ventriculitis (25%). Length of infection time which calculated from the beginning of surgery was 350.20 days or 11 months. The most common pathogen types are S. epidermidis followed by P. aeruginosa, E. coli, and A. baumanii. There were many risk factors for shunt infection, but the interesting fact was the level of pre-operative albumin. There was a significant difference between low albumin levels (<3.0) and normal albumin (≥3.0) levels against the risk of exposure shunt, p = 0.015. It means there is asignificant difference between low pre-operative albumin and normal level for the risk of theexposed shunt.

  7. Congenital portosystemic shunts: imaging findings and clinical presentations in 11 patients.

    PubMed

    Konstas, Angelos A; Digumarthy, Subba R; Avery, Laura L; Wallace, Karen L; Lisovsky, Mikhail; Misdraji, Joseph; Hahn, Peter F

    2011-11-01

    To evaluate the clinical anatomy and presentations of congenital portosystemic shunts, and determine features that promote recognition on imaging. Institutional review board approval was obtained for this HIPAA-compliant study. The requirement for written informed consent was waived. Radiology reports were retrospectively reviewed from non-cirrhotic patients who underwent imaging studies from January 1999 through February 2009. Clinical sources reviewed included electronic medical records, archived images and histopathological material. Eleven patients with congenital portosystemic shunts were identified (six male and five female; age range 20 days to 84 years). Seven patients had extrahepatic and four patients had intrahepatic shunts. All 11 patients had absent or hypoplastic intrahepatic portal veins, a feature detected by CT and MRI, but not by US. Seven patients presented with shunt complications and four with presentations unrelated to shunt pathophysiology. Three adult patients had four splenic artery aneurysms. Prospective radiological evaluation of five adult patients with cross-sectional imaging had failed prospectively to recognize the presence of congenital portosystemic shunts on one or more imaging examinations. Congenital portosystemic shunts are associated with splenic artery aneurysms, a previously unrecognized association. Portosystemic shunts were undetected during prospective radiologic evaluation in the majority of adult patients, highlighting the need to alert radiologists to this congenital anomaly. Copyright © 2010. Published by Elsevier Ireland Ltd.

  8. Slit ventricle syndrome and early-onset secondary craniosynostosis in an infant

    PubMed Central

    Ryoo, Hyun Gee; Kim, Seung-Ki; Cheon, Jung-Eun; Lee, Ji Yeoun; Wang, Kyu-Chang; Phi, Ji Hoon

    2014-01-01

    Patient: Female, 14 months Final Diagnosis: Slit ventricle syndrome Symptoms: Hydrocephalus • lethargy and seizure • vomiting Medication: — Clinical Procedure: — Specialty: Pediatrics and Neonatology Objective: Challenging differential diagnosis Background: Shunt surgery is a common solution for hydrocephalus in infancy. Slit ventricle syndrome and secondary craniosynostosis are late-onset complications after shunt placement; these 2 conditions occasionally occur together. Case Report: We report a case of early-onset secondary craniosynostosis with slit ventricle syndrome after shunt surgery in an infant, which led to a catastrophic increase in intracranial pressure (ICP). A 4-month-old girl with a Dandy-Walker malformation underwent a ventriculoperitoneal shunt procedure. Her head circumference (HC) gradually decreased to approximately the 5th percentile for her age group after shunt surgery. Seven months later, she developed increased ICP symptoms and underwent a shunt revision with a diagnosis of shunt malfunction. Her symptoms were temporarily relieved, but she repeatedly visited the emergency room (ER) for the same symptoms and finally collapsed, with an abrupt increase in ICP, 3 months later. Further evaluation revealed the emergence of sagittal synostosis at 7 months after initial shunt surgery. After reviewing all clinical data, slit ventricle syndrome combined with secondary craniosynostosis was diagnosed. Emergent cranial expansion surgery with shunt revision was performed, and the increased ICP signs subsided in the following days. Conclusions: Clinical suspicion and long-term HC monitoring are important in the diagnosis of slit ventricle syndrome and secondary craniosynostosis after shunt surgery, even in infants and young children. PMID:24944727

  9. Congenital Shunts of the Portal Venous System: Case-series of Uncommon Shunts.

    PubMed

    Santos, Liliana; Nobre, Susana; Laezza, Nadia; Cunha, Catarina; Gonçalves, Isabel; Lopes, Maria F

    Congenital shunts of the portal venous system are rare entities that can present in children with clinical heterogeneity. To evaluate the clinical course of children with uncommon shunts presenting to our institution and examine the available literature on this topic. Medical records of children with rare forms of congenital shunts were retrospectively reviewed for demographics, symptoms, management, and outcome between 2003 and 2016. Three female patients with congenital shunts, including a congenital mesenterico-portal Rex shunt (n = 1) and congenital portosystemic shunts (CPSS) (n = 2), were referred for surgical evaluation between ages 4 and 9. Median follow-up was 8 years (range, 6-13 years). One asymptomatic patient did not require treatment and remained disease-free during long-term follow-up. The other 2 patients with CPSS and unusual symptoms, including liver focal nodular hyperplasia (FNH) in infancy (n = 1) and bleeding from esophageal varices (n = 1), showed subsequent progression to liver nodules that were managed by endovascular shunt occlusion. One patient showed symptom resolution and the other showed stable lesions at last follow-up. Literature yielded descriptions of two cases of congenital mesenterico-portal Rex shunt, one case of coincident CPSS and FNH in infancy, but zero reports of bleeding from esophageal varices. This case series examines each distinct patient's presentation, discusses the diagnosis, management and outcome and compares findings while discussing literature on this topic. A high index of suspicion and familiarity with unusual forms and treatment options is required to allow timely diagnosis and appropriate treatment.

  10. Predictors of Shunt Dysfunction and Overall Survival in Patients with Variceal Bleeding Treated with Transjugular Portosystemic Shunt Creation Using the Fluency Stent Graft.

    PubMed

    Wan, Yue-Meng; Li, Yu-Hua; Xu, Ying; Wu, Hua-Mei; Li, Ying-Chun; Wu, Xi-Nan; Yang, Jin-Hui

    2018-01-16

    Transjugular intrahepatic portosystemic shunt (TIPS) is an established method for portal hypertension. This study was to investigate the long-term safety, technical success, and patency of TIPS, and to determine the risk factors and clinical impacts of shunt dysfunction. A total of 154 consecutive patients undergoing embolotherapy of gastric coronary vein and/or short gastric vein and TIPS creation were prospectively studied. Follow-up data included technical success, patency and revision of TIPS, and overall survival of patients. During the study, the primary and secondary technical success rates were 98.7% and 100%, respectively. Sixty-three patients developed shunt dysfunction, 30 with shunt stenosis and 33 with shunt occlusion. The cumulative 60-month primary, primary assisted, and secondary patency rates were 19.6%, 43.0%, and 93.4%, respectively. The cumulative 60-month overall survival rates were similar between the TIPS dysfunction group and the TIPS non-dysfunction group (68.6% vs. 58.6%, P = .096). Baseline portal vein thrombosis (P < .001), use of bare stents (P = .018), and portal pressure gradient (PPG) (P = .020) were independent predictors for shunt dysfunction, hepatocellular carcinoma (P < .001), and ascites (P = .003) for overall survival. The accuracy of PPG for shunt dysfunction was statistically significant (P < .001), and a cutoff value of 8.5 had 77.8% sensitivity and 64.8% specificity. The long-term safety, technical success, and patency of TIPS were good; baseline portal vein thrombosis, use of bare stents, and PPG were significantly associated with shunt dysfunction; shunt dysfunction has little impact on patients' long-term survival because of high secondary patency rates. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  11. Clinical and economic consequences of antibiotic-impregnated cerebrospinal fluid shunt catheters.

    PubMed

    Eymann, Regina; Chehab, Somar; Strowitzki, Martin; Steudel, Wolf-Ingo; Kiefer, Michael

    2008-06-01

    The authors evaluated the safety and efficacy of antibiotic-impregnated shunt catheters (AISCs) and determined the cost-benefit ratio related to the fact that AISCs increase the implant costs of a shunt procedure by approximately $400 per patient. The control group comprised 98 adults with chronic hydrocephalus and 22 children, who were treated without AISCs (non-AISCs). In the treatment group, AISCs (Bactiseal, Codman, Johnson & Johnson) were implanted in 171 adults and 26 children. The minimum follow-up period was 6 months. Important risk factors for shunt infections (such as age, comorbidity, cause of hydrocephalus, operating time, and duration of external cerebrospinal fluid drainage prior to shunt placement) did not differ between the study and control groups. In the pediatric AISC group, the frequency of premature, shunt-treated infants and the incidence of external ventricular drainage prior to shunt insertion were actually higher than those in the non-AISC group. When using AISCs, the shunt infection rate dropped from 4 to 0.6% and from 13.6 to 3.8% in the adult and the pediatric cohort, respectively. Overall the infection rate decreased from 5.8 to 1%, which was statistically significant (p = 0.0145). The average costs of a single shunt infection were $17,300 and $13,000 in children and adults, respectively. The cost-benefit calculation assumed to have saved shunt infection-related costs of approximately $50,000 in 197 AISC-treated patients due to the reduction in shunt infection rate in this group compared with costs in the control group. Despite the incremental implant costs associated with the use of AISCs, the overall reduction in infection-related costs made the use of AISCs cost beneficial in the authors' department. From clinical and economic perspectives, AISCs are seemingly a valuable addition in hydrocephalus therapy.

  12. Use of mathematic modeling to compare and predict hemodynamic effects of the modified Blalock-Taussig and right ventricle-pulmonary artery shunts for hypoplastic left heart syndrome.

    PubMed

    Bove, Edward L; Migliavacca, Francesco; de Leval, Marc R; Balossino, Rossella; Pennati, Giancarlo; Lloyd, Thomas R; Khambadkone, Sachin; Hsia, Tain-Yen; Dubini, Gabriele

    2008-08-01

    Stage one reconstruction (Norwood operation) for hypoplastic left heart syndrome can be performed with either a modified Blalock-Taussig shunt or a right ventricle-pulmonary artery shunt. Both methods have certain inherent characteristics. It is postulated that mathematic modeling could help elucidate these differences. Three-dimensional computer models of the Blalock-Taussig shunt and right ventricle-pulmonary artery shunt modifications of the Norwood operation were developed by using the finite volume method. Conduits of 3, 3.5, and 4 mm were used in the Blalock-Taussig shunt model, whereas conduits of 4, 5, and 6 mm were used in the right ventricle-pulmonary artery shunt model. The hydraulic nets (lumped resistances, compliances, inertances, and elastances) were identical in the 2 models. A multiscale approach was adopted to couple the 3-dimensional models with the circulation net. Computer simulations were compared with postoperative catheterization data. Good correlation was found between predicted and observed data. For the right ventricle-pulmonary artery shunt modification, there was higher aortic diastolic pressure, decreased pulmonary artery pressure, lower Qp/Qs ratio, and higher coronary perfusion pressure. Mathematic modeling predicted minimal regurgitant flow in the right ventricle-pulmonary artery shunt model, which correlated with postoperative Doppler measurements. The right ventricle-pulmonary artery shunt demonstrated lower stroke work and a higher mechanical efficiency (stroke work/total mechanical energy). The close correlation between predicted and observed data supports the use of mathematic modeling in the design and assessment of surgical procedures. The potentially damaging effects of a systemic ventriculotomy in the right ventricle-pulmonary artery shunt modification of the Norwood operation have not been analyzed.

  13. Frontal and occipital horn ratio is associated with multifocal intraparenchymal hemorrhages in neonatal shunted hydrocephalus.

    PubMed

    Oushy, Soliman; Parker, Jonathon J; Campbell, Kristen; Palmer, Claire; Wilkinson, Corbett; Stence, Nicholas V; Handler, Michael H; Mirsky, David M

    2017-11-01

    OBJECTIVE Placement of a cerebrospinal fluid diversion device (i.e., shunt) is a routine pediatric neurosurgical procedure, often performed in the first weeks of life for treatment of congenital hydrocephalus. In the postoperative period, shunt placement may be complicated by subdural, catheter tract, parenchymal, and intraventricular hemorrhages. The authors observed a subset of infants and neonates who developed multifocal intraparenchymal hemorrhages (MIPH) following shunt placement and sought to determine any predisposing perioperative variables. METHODS A retrospective review of the electronic medical record at a tertiary-care children's hospital was performed for the period 1998-2015. Inclusion criteria consisted of shunt placement, age < 30 days, and available pre- and postoperative brain imaging. The following data were collected and analyzed for each case: ventricular size ratios, laboratory values, clinical presentation, shunt and valve type, and operative timing and approach. RESULTS A total of 121 neonates met the inclusion criteria for the study, and 11 patients (9.1%) had MIPH following shunt placement. The preoperative frontal and occipital horn ratio (FOR) was significantly higher in the patients with MIPH than in those without (0.65 vs 0.57, p < 0.001). The change in FOR (∆FOR) after shunt placement was significantly greater in the MIPH group (0.14 vs 0.08, p = 0.04). Among neonates who developed MIPH, aqueductal stenosis was the most common etiology (45%). The type of shunt valve was associated with incidence of MIPH (p < 0.001). Preoperative clinical parameters, including head circumference, bulging fontanelle, and coagulopathy, were not significantly associated with development of MIPH. CONCLUSIONS MIPH represents an underrecognized complication of neonatal shunted hydrocephalus. Markers of severity of ventriculomegaly (FOR) and ventricular response to CSF diversion (∆FOR) were significantly associated with occurrence of MIPH. Choice of shunt and etiology of hydrocephalus were also significantly associated with MIPH. After adjusting for corrected age, etiology of hydrocephalus, and shunt setting, the authors found that ∆FOR after shunting was still associated with MIPH. A prospective study of MIPH prevention strategies and assessment of possible implications for patient outcomes is needed.

  14. Management of idiopathic normal-pressure hydrocephalus: a multiinstitutional study conducted in Japan.

    PubMed

    Mori, K

    2001-12-01

    A cooperative study was undertaken to identify factors that could be used to predict a favorable outcome after extracranial cerebrospinal fluid (CSF) diversion (shunting) in patients with suspected idiopathic normal-pressure hydrocephalus (NPH). Questionnaires concerning patients with suspected idiopathic NPH were sent to 14 members of the Committee for Scientific Research on Intractable Hydrocephalus, sponsored by the Ministry of Health and Welfare of Japan. After the questionnaires were returned, a retrospective analysis of the responses was undertaken. To be included in the study, patients had to be 65 years of age or older and had to have undergone surgery between October 1995 and October 1998. Clinical measures included degrees of gait disturbance, dementia, and urinary incontinence as evaluated before. 3 months after, and 3 years after shunt placement. Diagnostic tests in various combinations included lumbar puncture in which CSF was withdrawn; intracranial pressure monitoring; measurements of CSF outflow resistance, level of serum alpha-1-antichymotrypsin, cerebral arteriovenous differences of oxygen content, and cerebral blood flow; and computerized tomography cisternography. In this study, 120 patients were identified as having idiopathic NPH and these patients underwent placement of shunts. A ventriculoperitoneal shunt with a programmable valve was used in two thirds of the patients. At the end of 3 months (early assessment), there was an 80% overall rate of clinical improvement, which dropped to 73.3% of the 105 patients who could be evaluated at the end of the 3-year study. Of the three variables, gait disturbance was most improved, both at early and late testing periods. Shunt complications occurred in 22 (18.3%) of the patients. Patients suspected of having idiopathic NPH did not form a homogeneous group, making it difficult to select those who would most likely respond to CSF diversion. Of the diagnostic studies, the most reliable result was improvement in clinical symptoms following a lumbar puncture in which CSF was withdrawn. The use of a programmable valve is recommended because it offers advantages in preventing problems of over- and underdrainage.

  15. To shunt or not to shunt? An experimental study comparing temporary vascular shunts and venous ligation as damage control techniques for vascular trauma.

    PubMed

    Marinho de Oliveira Góes Junior, Adenauer; de Campos Vieira Abib, Simone; de Seixas Alves, Maria Teresa; Venerando da Silva Ferreira, Paulo Sérgio; Carvalho de Andrade, Mariseth

    2014-04-01

    To evaluate vascular flow through temporary vascular shunts inserted into peripheral arteries and veins and the repercussion, on the arterial perfusion, of venous ligation and venous shunt insertion in an experimental model for damage control. Experimental study in pigs. Animals were distributed in 5 groups: group 1, right external iliac artery (EIA) shunting and right external iliac vein (EIV) ligation; group 2, right EIA shunting and right EIV shunting; group 3, right EIV ligation; group 4, right EIV shunting; group 5, no vascular shunting and no venous ligation. Flowmeters were used to measure vascular flow on right and left external iliac vessels, and blood samples were collected from the EIVs for biochemical analysis. A right anterior limb biopsy was performed before shock. Hemorrhagic shock was induced through the external right jugular vein, until the vascular flow through right iliac external artery shunt or right iliac external vein shunt (group 4) ceased or until the animal's death. After the end of the experiments, biopsies of bilateral hind limb were obtained for histologic analysis. For statistical analysis, Microsoft Office Excel 2007 and BioEstat 5.0 (2007) were used. In the absence of hemorrhagic shock, venous ligation (group 1) was associated with a 38.8% reduction (P < 0.05) and venous shunting with a 28.4% reduction on the vascular flow through the arterial shunt. When associated with hemorrhagic shock, the mean vascular flow on the right EIA was 13 mL/min and on the left EIA was 41.2 mL/min; on group 2, the right EIA flow was 8.5 mL/min and the left EIA flow was 8.1 mL/min. When associated with hemorrhagic shock, the pO2 was 25.8 mm Hg on right EIV and 33.8 mm Hg on the left EIV for group 1 (P < 0.05), whereas for group 2, the pO2 was 22.6 mm Hg on right EIV and 22.8 mm Hg on the left EIV. On group 1, serum potassium was 3.84 mEq/L on the right EIV and 3.96 mEq/L on the left EIV, whereas on group 2, it was 7.1 mEq/L on the right EIV and 5.88 mEq/L on the left EIV (P < 0.05). In the developed experimental model, venous shunting, when compared with venous ligation, offered less resistance to vascular flow through the arterial shunt and allowed a more efficient limb venous drainage than simple vein ligature. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Importance of technical preparation of intraarterial shunts to prevent iatrogenic arterial injury during urgent procedures.

    PubMed

    Awad, Nadia; Choudry, Rashad; Durinka, Joel; Prabhu, Aparna; Dissin, Jonathan

    2013-02-01

    Although intraarterial shunting during carotid endarterectomy is a well-defined practice, its use remains controversial. Complication rates associated with shunt placement remain low, but may be underreported. When complications secondary to routine intraarterial shunting occur, they can cause significant morbidity or even mortality, emphasizing the importance of meticulous technique to prevent adverse outcomes. We report a case of internal carotid artery dissection and pseuedoaneurysm due to the technical failure of a safety device of an intraarterial shunt used during carotid endarterectomy.

  17. Impact of Anatomical, Procedural, and Operator Skill Factors on the Success and Duration of Fluoroscopy-Guided Transjugular Intrahepatic Portosystemic Shunt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marquardt, Steffen, E-mail: marquardt.steffen@mh-hannover.de; Rodt, Thomas, E-mail: rodt.thomas@mh-hannover.de; Rosenthal, Herbert, E-mail: rosenthal.herbert@mh-hannover.de

    PurposeTo assess the impact of anatomical, procedural, and operator skill factors on the success and duration of fluoroscopy-guided transjugular intrahepatic portoystemic shunt following standard operating procedure (SOP).Material and MethodsDuring a 32-month period, 102 patients underwent transjugular intrahepatic portosystemic shunt creation (TIPS) by two interventional radiologists (IR) following our institutional SOP based on fluoroscopy guidance. Both demographic and procedural data were assessed. The duration of the intervention (D{sub Int}) and of the portal vein puncture (D{sub Punct}) was analyzed depending on the skill level of the IR as well as the anatomic or procedural factors.ResultsIn 99 of the 102 patients, successfulmore » TIPS without peri-procedural complications was performed. The mean D{sub Int} (IR1: 77 min; IR2: 51 min, P < 0.005) and the mean D{sub Punct} (IR1: 19 min; IR2: 13 min, P < 0.005) were significantly higher in TIPS performed by IR1 (with 2 years of clinical experience performing TIPS, n = 38) than by IR2 (>10 years of clinical experience performing TIPS, n = 61), (P < 0.005 both, Mann–Whitney U test). D{sub Int} showed a higher correlation with D{sub Punct} for IR2 (R{sup 2} = 0.63) than for IR1 (R{sup 2} = 0.13). There was no significant difference in the D{sub Punct} for both IRs with regard to the success of the wedged portography (P = 0.90), diameter of the portal vein (P = 0.60), central right portal vein length (P = 0.49), or liver function (MELD-Score before the TIPS procedure; P = 0.14).ConclusionTIPS following SOP is safe, fast, and reliable. The only significant factor for shorter D{sub Punct} and D{sub Int} was the clinical experience of the IR. Anatomic variability, successful portography, or liver function did not alter the duration or technical success of TIPS.« less

  18. Left hemisphere structural connectivity abnormality in pediatric hydrocephalus patients following surgery.

    PubMed

    Yuan, Weihong; Meller, Artur; Shimony, Joshua S; Nash, Tiffany; Jones, Blaise V; Holland, Scott K; Altaye, Mekibib; Barnard, Holly; Phillips, Jannel; Powell, Stephanie; McKinstry, Robert C; Limbrick, David D; Rajagopal, Akila; Mangano, Francesco T

    2016-01-01

    Neuroimaging research in surgically treated pediatric hydrocephalus patients remains challenging due to the artifact caused by programmable shunt. Our previous study has demonstrated significant alterations in the whole brain white matter structural connectivity based on diffusion tensor imaging (DTI) and graph theoretical analysis in children with hydrocephalus prior to surgery or in surgically treated children without programmable shunts. This study seeks to investigate the impact of brain injury on the topological features in the left hemisphere, contratelateral to the shunt placement, which will avoid the influence of shunt artifacts and makes further group comparisons feasible for children with programmable shunt valves. Three groups of children (34 in the control group, 12 in the 3-month post-surgery group, and 24 in the 12-month post-surgery group, age between 1 and 18 years) were included in the study. The structural connectivity data processing and analysis were performed based on DTI and graph theoretical analysis. Specific procedures were revised to include only left brain imaging data in normalization, parcellation, and fiber counting from DTI tractography. Our results showed that, when compared to controls, children with hydrocephalus in both the 3-month and 12-month post-surgery groups had significantly lower normalized clustering coefficient, lower small-worldness, and higher global efficiency (all p  < 0.05, corrected). At a regional level, both patient groups showed significant alteration in one or more regional connectivity measures in a series of brain regions in the left hemisphere (8 and 10 regions in the 3-month post-surgery and the 12-month post-surgery group, respectively, all p  < 0.05, corrected). No significant correlation was found between any of the global or regional measures and the contemporaneous neuropsychological outcomes [the General Adaptive Composite (GAC) from the Adaptive Behavior Assessment System, Second Edition (ABAS-II)]. However, one global network measure (global efficiency) and two regional network measures in the insula (local efficiency and between centrality) tested at 3-month post-surgery were found to correlate with GAC score tested at 12-month post-surgery with statistical significance (all p  < 0.05, corrected). Our data showed that the structural connectivity analysis based on DTI and graph theory was sensitive in detecting both global and regional network abnormality when the analysis was conducted in the left hemisphere only. This approach provides a new avenue enabling the application of advanced neuroimaging analysis methods in quantifying brain damage in children with hydrocephalus surgically treated with programmable shunts.

  19. Field Performance of Photovoltaic Systems in the Tucson Desert

    NASA Astrophysics Data System (ADS)

    Orsburn, Sean; Brooks, Adria; Cormode, Daniel; Greenberg, James; Hardesty, Garrett; Lonij, Vincent; Salhab, Anas; St. Germaine, Tyler; Torres, Gabe; Cronin, Alexander

    2011-10-01

    At the Tucson Electric Power (TEP) solar test yard, over 20 different grid-connected photovoltaic (PV) systems are being tested. The goal at the TEP solar test yard is to measure and model real-world performance of PV systems and to benchmark new technologies such as holographic concentrators. By studying voltage and current produced by the PV systems as a function of incident irradiance, and module temperature, we can compare our measurements of field-performance (in a harsh desert environment) to manufacturer specifications (determined under laboratory conditions). In order to measure high-voltage and high-current signals, we designed and built reliable, accurate sensors that can handle extreme desert temperatures. We will present several benchmarks of sensors in a controlled environment, including shunt resistors and Hall-effect current sensors, to determine temperature drift and accuracy. Finally we will present preliminary field measurements of PV performance for several different PV technologies.

  20. Ex-PRESS outcomes using mitomycin-C, Ologen alone, Ologen with 5-fluorouracil.

    PubMed

    Menda, Shivali A; Lowry, Eugene A; Porco, Travis C; Stamper, Robert L; Rubin, Michel R; Han, Ying

    2015-06-01

    To compare the complication rate and effectiveness of mitomycin C (MMC), Ologen alone, and Ologen with 5-fluorouracil (5-FU) as adjunctives with Ex-PRESS mini shunt for medically uncontrolled glaucoma. Retrospective comparative study of 59 Ex-PRESS mini shunt trabeculectomy operations coupled with Ologen implantation alone, transient MMC application or Ologen implantation with 5-FU as adjunctive treatment. Eight eyes (7 patients) received Ologen alone, 37 eyes (34 patients) received MMC, and 14 eyes (14 patients) received Ologen with 5-FU as adjunctive therapy. Baseline characteristics, adjunctive used during operation, along with outcomes including intraocular pressure (IOP), number of anti-hypertensive drops, visual acuity, and complications were documented and compared. The primary outcome was IOP at 12 months. Variables were compared with r × c Fisher tests. The Ologen only group had a significantly higher IOP at 12 months (20.5 ± 10.23 mmHg) compared with Ologen combined with 5-FU (12.2 ± 1.47 mmHg) or MMC (13.8 ± 4.37 mmHg) (p = 0.015, linear mixed model). The Ologen only cohort also had a higher re-operation rate (p = 0.01, Fisher's Exact Test) and higher rate of bleb leak (p = 0.02, Fisher's Exact Test). Visual acuity was similar among all three groups. 5-FU with Ologen is as effective as MMC in maintaining IOP following Ex-PRESS shunt surgery at 1 year. However, Ologen alone may not be as effective as the other two adjunctive agents.

  1. Non-invasive assessment of pulsatile intracranial pressure with phase-contrast magnetic resonance imaging

    PubMed Central

    Lindstrøm, Erika Kristina; Vatnehol, Svein Are Sirirud; Mardal, Kent-André; Emblem, Kyrre Eeg; Eide, Per Kristian

    2017-01-01

    Invasive monitoring of pulsatile intracranial pressure can accurately predict shunt response in patients with idiopathic normal pressure hydrocephalus, but may potentially cause complications such as bleeding and infection. We tested how a proposed surrogate parameter for pulsatile intracranial pressure, the phase-contrast magnetic resonance imaging derived pulse pressure gradient, compared with its invasive counterpart. In 22 patients with suspected idiopathic normal pressure hydrocephalus, preceding invasive intracranial pressure monitoring, and any surgical shunt procedure, we calculated the pulse pressure gradient from phase-contrast magnetic resonance imaging derived cerebrospinal fluid flow velocities obtained at the upper cervical spinal canal using a simplified Navier-Stokes equation. Repeated measurements of the pulse pressure gradient were also undertaken in four healthy controls. Of 17 shunted patients, 16 responded, indicating high proportion of “true” normal pressure hydrocephalus in the patient cohort. However, there was no correlation between the magnetic resonance imaging derived pulse pressure gradient and pulsatile intracranial pressure (R = -.18, P = .43). Pulse pressure gradients were also similar in patients and healthy controls (P = .26), and did not differ between individuals with pulsatile intracranial pressure above or below established thresholds for shunt treatment (P = .97). Assessment of pulse pressure gradient at level C2 was therefore not found feasible to replace invasive monitoring of pulsatile intracranial pressure in selection of patients with idiopathic normal pressure hydrocephalus for surgical shunting. Unlike invasive, overnight monitoring, the pulse pressure gradient from magnetic resonance imaging comprises short-term pressure fluctuations only. Moreover, complexity of cervical cerebrospinal fluid flow and -pulsatility at the upper cervical spinal canal may render the pulse pressure gradient a poor surrogate marker for intracranial pressure pulsations. PMID:29190788

  2. Cerebrospinal fluid volume measurements in hydrocephalic rats.

    PubMed

    Basati, Sukhraaj; Desai, Bhargav; Alaraj, Ali; Charbel, Fady; Linninger, Andreas

    2012-10-01

    Object Experimental data about the evolution of intracranial volume and pressure in cases of hydrocephalus are limited due to the lack of available monitoring techniques. In this study, the authors validate intracranial CSF volume measurements within the lateral ventricle, while simultaneously using impedance sensors and pressure transducers in hydrocephalic animals. Methods A volume sensor was fabricated and connected to a catheter that was used as a shunt to withdraw CSF. In vitro bench-top calibration experiments were created to provide data for the animal experiments and to validate the sensors. To validate the measurement technique in a physiological system, hydrocephalus was induced in weanling rats by kaolin injection into the cisterna magna. At 28 days after induction, the sensor was implanted into the lateral ventricles. After sealing the skull using dental cement, an acute CSF drainage/infusion protocol consisting of 4 sequential phases was performed with a pump. Implant location was confirmed via radiography using intraventricular iohexol contrast administration. Results Controlled CSF shunting in vivo with hydrocephalic rats resulted in precise and accurate sensor measurements (r = 0.98). Shunting resulted in a 17.3% maximum measurement error between measured volume and actual volume as assessed by a Bland-Altman plot. A secondary outcome confirmed that both ventricular volume and intracranial pressure decreased during CSF shunting and increased during infusion. Ventricular enlargement consistent with successful hydrocephalus induction was confirmed using imaging, as well as postmortem. These results indicate that volume monitoring is feasible for clinical cases of hydrocephalus. Conclusions This work marks a departure from traditional shunting systems currently used to treat hydrocephalus. The overall clinical application is to provide alternative monitoring and treatment options for patients. Future work includes development and testing of a chronic (long-term) volume monitoring system.

  3. Non-invasive assessment of pulsatile intracranial pressure with phase-contrast magnetic resonance imaging.

    PubMed

    Ringstad, Geir; Lindstrøm, Erika Kristina; Vatnehol, Svein Are Sirirud; Mardal, Kent-André; Emblem, Kyrre Eeg; Eide, Per Kristian

    2017-01-01

    Invasive monitoring of pulsatile intracranial pressure can accurately predict shunt response in patients with idiopathic normal pressure hydrocephalus, but may potentially cause complications such as bleeding and infection. We tested how a proposed surrogate parameter for pulsatile intracranial pressure, the phase-contrast magnetic resonance imaging derived pulse pressure gradient, compared with its invasive counterpart. In 22 patients with suspected idiopathic normal pressure hydrocephalus, preceding invasive intracranial pressure monitoring, and any surgical shunt procedure, we calculated the pulse pressure gradient from phase-contrast magnetic resonance imaging derived cerebrospinal fluid flow velocities obtained at the upper cervical spinal canal using a simplified Navier-Stokes equation. Repeated measurements of the pulse pressure gradient were also undertaken in four healthy controls. Of 17 shunted patients, 16 responded, indicating high proportion of "true" normal pressure hydrocephalus in the patient cohort. However, there was no correlation between the magnetic resonance imaging derived pulse pressure gradient and pulsatile intracranial pressure (R = -.18, P = .43). Pulse pressure gradients were also similar in patients and healthy controls (P = .26), and did not differ between individuals with pulsatile intracranial pressure above or below established thresholds for shunt treatment (P = .97). Assessment of pulse pressure gradient at level C2 was therefore not found feasible to replace invasive monitoring of pulsatile intracranial pressure in selection of patients with idiopathic normal pressure hydrocephalus for surgical shunting. Unlike invasive, overnight monitoring, the pulse pressure gradient from magnetic resonance imaging comprises short-term pressure fluctuations only. Moreover, complexity of cervical cerebrospinal fluid flow and -pulsatility at the upper cervical spinal canal may render the pulse pressure gradient a poor surrogate marker for intracranial pressure pulsations.

  4. A cranial nail for fetal shunting.

    PubMed

    Saunders, R L; Simmons, G M; Edwards, W H; Crow, H C

    1985-01-01

    A small number of human fetal hydrocephalics have been treated by ventriculoamniotic shunts of silastic tubing. The Colorado device appears to be the one most commonly used. The original experimental device tested on a primate model resembled a hollow shingle nail. This was designed by Michedja and Hodgen, contained a spring valve, measured approximately 32 X 4 mm and was placed by hysterotomy. An attractive feature of this design was its fixation by impaction in the skull, preventing displacement by fetal activity, a reported disadvantage with the silastic devices. To our knowledge, no one has used this nail-like design and tailored it to transuterine percutaneous placement in a human case.

  5. In vitro performance of the fixed and adjustable gravity-assisted unit with and without motion-evidence of motion-induced flow.

    PubMed

    Kimura, Takaoki; Schulz, Matthias; Shimoji, Kazuaki; Miyajima, Masakazu; Arai, Hajime; Thomale, Ulrich-Wilhelm

    2016-10-01

    Anti-siphon devices and gravitational-assisted valves have been introduced to counteract the effects of overdrainage after implantation of a shunt system. The study examined the flow performance of two gravitational-assisted valves (shunt assistant - SA and programmable shunt assistant - proSA, Miethke & Co. KG, Potsdam, Germany) in an in vitro shunt laboratory with and without motion. An in vitro laboratory setup was used to model the cerebrospinal fluid (CSF) drainage conditions similar to a ventriculo-peritoneal shunt and to test the SA (resistance of +20 cmH2O in 90°) and proSA (adjustable resistance of 0 to +40 cmH2O in 90°). The differential pressure (DP) through the simulated shunt and tested valve was adjusted between 0 and 60 cmH2O by combinations of different inflow pressures (40, 30, 20, 10, and 0 cmH2O) and the hydrostatic negative outflow pressure (0, -20, and -40 cmH2O) in several differing device positions (0°, 30°, 60°, and 90°). In addition, the two devices were tested under vertical motion with movement frequencies of 2, 3, and 4 Hz. Both gravity-assisted units effectively counteract the hydrostatic effect in relation to the chosen differential pressure. The setting the proSA resulted in flow reductions in the 90° position according to the chosen resistance of the device. Angulation-related flow changes were similar in the two devices in 30-90° position, however, in the 0-30° position, a higher flow is seen in the proSA. Repeated vertical movement significantly increased flow through both devices. While with the proSA a 2-Hz motion was not able to induce additional flow (0.006 ± 0.05 ml/min), 3- and 4-Hz motion significantly induced higher flow values (3 Hz: +0.56 ± 0.12 ml/min, 4 Hz: +0.54 ± 0.04 ml/min). The flow through the SA was not induced by vertical movements at a low DP of 10 cmH2O at all frequencies, but at DPs of 30 cmH2O and higher, all frequencies significantly induced higher flow values (2 Hz: +0.36 ± 0.14 ml/min, 3 Hz: +0.32 ± 0.08 ml/min, 4 Hz: +0.28 ± 0.09 ml/min). In a static setup, both tested valves effectively counteracted the hydrostatic effect according to their adjusted or predefined resistance in vertical position. Motion-induced increased flow was demonstrated for both devices with different patterns of flow depending on applied DP and setting of the respective valve. The documented increased drainage should be considered when selecting appropriate valves and settings in very active patients.

  6. Continuous monitoring of intracranial pressure after endoscopic third ventriculostomy in the management of CSF shunt failure.

    PubMed

    Elgamal, E A

    2010-04-01

    The effectiveness of continuous intracranial pressure (ICP) monitoring in the adaptation period, after endoscopic third ventriculostomy (ETV), and removal of the failed shunt in the management of CSF shunt failure is assessed. Nine patients with active hydrocephalus presenting with CSF shunt obstruction or infection were managed by ETV, removal of the shunt and insertion of an external ventricular drain (EVD) containing an ICP sensor for the purpose of postoperative monitoring of the ICP, and intermittent drainage of CSF. Patient ages ranged from 8 months to 24 years, and six of them were females. Hydrocephalus was obstructive in seven patients, and multiloculated in two. Six patients had an ventriculoperitoneal shunt (VPS), one with a bilateral VPS, one patient had a ventriculoatrial shunt, and one had a VPS and cystoperitoneal shunt (CPS). Shunt failure was caused by obstruction in six patients and infection in three. The post-operative ICP monitoring period ranged from 1-7 days. Intracranial hypertension was persistent in the first day after ETV in 3 patients, and up to 110 mL of CSF were drained to improve its symptoms. ETV was successful in six patients and 3 had permanent VPS. Post-operative continuous ICP monitoring and EVD insertion were very useful in the treatment of CSF shunt failure with ETV. This procedure allowed intermittent CSF drainage, relieving symptoms of elevated ICP, and provided accurate assessment of the success of the ETV and patency of the stoma in the early postoperative days by CT ventriculography and can also be used to install antibiotics in cases of infection.

  7. Our initial experience with ventriculo-epiplooic shunt in treatment of hydrocephalus in two centers.

    PubMed

    Grigorean, Valentin Titus; Sandu, Aurelia Mihaela; Popescu, Mihai; Florian, Ioan Stefan; Lupascu, Cristian Dumitru; Ursulescu, Corina Lupascu

    Hydrocephalus represents impairment in cerebrospinal fluid (CSF) dynamics. If the treatment of hydrocephalus is considered difficult, the repeated revisions of ventriculo-peritoneal (VP) shunts are even more challenging. The aim of this article is to evaluate the efficiency of ventriculo-epiplooic (VEp) shunt as a feasible alternative in hydrocephalic patients. A technical modification regarding the insertion of peritoneal catheter was imagined: midline laparotomy 8-10cm long was performed in order to open the peritoneal cavity; the great omentum was dissected between its two layers; we placed the distal end of the catheter between the two epiplooic layers; a fenestration of 4cm in diameter into the visceral layer was also performed. A retrospective study of medical records of 15 consecutive patients with hydrocephalus treated with VEp shunt is also presented. Between 2008 and 2014 we performed VEp shunt in 15 patients: 5 with congenital hydrocephalus, 8 with secondary hydrocephalus and 2 with normal pressure hydrocephalus. There were 7 men and 8 women. VEp shunt was performed in 13 patients with multiple distal shunt failures and in 2 patients, with history of abdominal surgery, as de novo extracranial drainage procedure. The outcome was favorable in all cases, with no significant postoperative complications. VEp shunt is a new, safe and efficient surgical technique for the treatment of hydrocephalus. VEp shunt is indicated in patients with history of recurrent distal shunt failures, and in patients with history of open abdominal surgery and high risk for developing abdominal complications. Copyright © 2017 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  8. Normal pressure hydrocephalus: long-term outcome after shunt surgery.

    PubMed

    Pujari, S; Kharkar, S; Metellus, P; Shuck, J; Williams, M A; Rigamonti, D

    2008-11-01

    Little is known about the long-term clinical course and management of patients with normal pressure hydrocephalus (NPH) treated by cerebrospinal fluid (CSF) shunting. We retrospectively reviewed records of 55 patients diagnosed with idiopathic NPH (INPH) and treated with CSF shunts, all of whom were followed for more than 3 years after the original shunt surgery. At each annual follow-up visit, the patient was assessed by Folstein Mini Mental State Examination, detailed clinical evaluation of gait and assessment of headache, cognition, gait or urination, as assessed by the patient and relatives. The mean duration of follow-up was 5.9+/-2.5 years. There was an overall sustained improvement among all symptoms. Gait showed the highest maintenance of improvement over baseline (83% at 3 years and 87% at the last analysed follow-up of 7 years), cognition showed intermediary improvement (84% and 86%, respectively), and urinary incontinence showed the least improvement (84% and 80%, respectively). Fifty-three percent of patients required shunt revisions. Indications for revision included shunt malfunction (87%), infection (10%) and change of shunt configuration (3%). Overall, 74% revisions resulted in clinical improvement. Clinical improvement of patients with NPH can be sustained for 5-7 years in some patients with NPH, even if shunt revision surgery is needed multiple times. With earlier diagnosis and treatment of NPH and the increasing lifespan of the ageing population, the need for long-term follow-up after shunt surgery for NPH may be greater than it was in the past. Monitoring, identification and treatment of shunt obstruction is a key management principle.

  9. EMC Enhanced Constant ’Z’ Modulator.

    DTIC Science & Technology

    1984-06-01

    TUTHILL, Colonel, USAF Chief, Relilability & Compatibility Division FOR THE COMMANDER: JOHN A. RITZ Acting Chief, Plans Office 0 * - If your address...supply bypasses. 3.2.6 System Testing Breadboard system tests resulted in the replacement of the HP5082-3340 shunt mounted PIN diodes due to a carrer life

  10. Post ventriculoperitoneal shunt abdominal pseudocyst: Challenges posed in management.

    PubMed

    Hamid, Raashid; Baba, Aejaz A; Bhat, Nisar A; Mufti, Gowhar; Mir, Younis A; Sajad, Wani

    2017-01-01

    In patients with hydrocephalus, the abdominal cavity has been used for absorption of cerebrospinal fluid (CSF) since 1905. Ventriculoperitoneal (VP) shunt operation is followed by abdominal complications in about 5-47% cases. Abdominal CSF pseudo cyst is an uncommon, but well described complication. This survey was conducted to study the clinical profile and management of this entity. We present our experience with cases of CSF pseudo cyst in children. Retrospective analysis of 4 cases diagnosed to have abdominal pseudo cyst following VP shunt between 2008 and 2013. All the four cases were suspected clinically and diagnosis was confirmed by abdominal ultrasonography. In three patients, the cyst was multilocular and of varying size. Fourth one had a unilocular cyst at the lower end of VP shunt. All the four patients had features of varying degree raised intracranial pressure and a two patients had abdominal signs also. All the patients needed open exploration. Cyst fluid was drained and partial to complete excision of the cyst was done along with the repositioning of the shunt in abdominal cavity in three patients and exteriorization of shunt in one patient. Patients were followed for any further complication over a period of 1-year. Abdominal pseudo cyst is a rare complication after VP Shunt and could result in shunt malfunction or abdominal symptoms and signs. Whenever suspected it should be confirmed by imaging, followed by open exploration and repositioning of the shunt.

  11. Auxiliary Components for Kilopixel Transition Edge Sensor Arrays

    NASA Technical Reports Server (NTRS)

    Brown, Ari-David; Chervenak, James A.; Chuss, David; Hilton Gene C.; Mikula, Vilem; Henry, ROss; Wollack, Edward; Zhao, Yue

    2007-01-01

    We have fabricated transition edge sensor bolometer focal plane arrays sensitive to mm-submillimeter (0.1-3 THz) radiation for the Atacama Cosmology Telescope (ACT), which will probe the cosmic microwave background at 0.147,0.215, and 0.279 GHz. Central to the performance of these bolometers is a set of auxiliary resistive components. Here we discuss shunt resistors, which allow for tight optimization of bolometer time constant and sensitivity. Our shunt resistors consist of AuPd strips grown atop of interdigitated superconducting MoN, wires. We can tailor the shunt resistance by altering the dimensions of the AuPd strips and the pitch and width of the MoN, wires and can fabricate over 1000 shunts on a single 4" wafer. By modeling the resistance dependence of these parameters, a variety of different 0.77 +I-0.13 mOhm shunt resistors have been fabricated. This variety includes different shunts possessing MoN, wires with wire width equal to 1.5 and 10 microns and pitch equal to 4.5 and 26 microns, respectively. Our ability to set the resistance of the shunts hints at the scalability of our design. We have also integrated a Si02 capping layer into our shunt resistor fabrication scheme, which inhibits metal corrosion and eventual degradation of the shunt. Consequently, their robustness coupled with their high packing density makes these resistive components attractive for future kilopixel detector arrays.

  12. Universality of Non-Ohmic Shunt Leakage in Thin-Film Solar Cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dongaonkar, S.; Servaites, J.D.; Ford, G.M.

    2010-01-01

    We compare the dark current-voltage (IV) characteristics of three different thin-film solar cell types: hydrogenated amorphous silicon (a-Si:H) p-i-n cells, organic bulk heterojunction (BHJ) cells, and Cu(In,Ga)Se 2 (CIGS) cells. All three device types exhibit a significant shunt leakage current at low forward bias (V<~0.4) and reverse bias, which cannot be explained by the classical solar cell diode model. This parasitic shunt current exhibits non-Ohmic behavior, as opposed to the traditional constant shunt resistance model for photovoltaics. We show here that this shunt leakage (I sh) , across all three solar cell types considered, is characterized by the following commonmore » phenomenological features: (a) voltage symmetry about V=0 , (b) nonlinear (power law) voltage dependence, and (c) extremely weak temperature dependence. Based on this analysis, we provide a simple method of subtracting this shunt current component from the measured data and discuss its implications on dark IV parameter extraction. We propose a space charge limited (SCL) current model for capturing all these features of the shunt leakage in a consistent framework and discuss possible physical origin of the parasitic paths responsible for this shunt current mechanism.« less

  13. Difficulties of Distal Catheter Insertion of Ventriculoatrial Shunting in Infants and Little Children.

    PubMed

    Erdogan, Hakan; Altun, Adnan; Kuruoglu, Enis; Kaya, Ahmet Hilmi; Dagcinar, Adnan

    2017-09-26

    Ventriculoatrial (VA) shunting is a well-described cerebrospinal fluid diversion method for the treatment of hydrocephalus. However, it may be very challenging in infants and little children because of atrial catheter placement difficulties. This study aimed to create an algorithm to solve problems faced during open surgical procedures based on the present authors' experience. We conducted a retrospective analysis on 18 infants and children who underwent VA shunt insertion at the Department of Neurosurgery, Ondokuz Mayıs University School of Medicine Hospital between 2005 and 2012. Complications, clinical outcomes, revisions, and solutions for overcoming distal catheter placement difficulties were evaluated. Twenty-six VA shunt operations were performed in 18 patients. Six patients required eight VA shunt revisions. VA shunting was primarily performed from the internal jugular, facial, cephalic, and subclavian veins to the right atrium. In revision procedures, the internal jugular, cephalic, and subclavian veins were used. VA shunting in infants and little children requires careful surgical techniques. Neurosurgeons should necessarily have an appropriate strategy for VA shunting considering the complications and revisions. Our results suggest open surgical solutions to overcome distal catheter placement difficulties in this age group.

  14. Morphology of splenocaval congenital portosystemic shunts in dogs and cats.

    PubMed

    White, R N; Parry, A T

    2016-01-01

    To describe the anatomy of congenital portosystemic shunts involving the splenic vein communicating with the caudal vena cava at the level of the epiploic foramen. A retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. Ninety-eight dogs and eight cats met the inclusion criteria of a congenital portosystemic shunt involving the splenic vein communicating with the prehepatic caudal vena cava plus recorded intra-operative mesenteric portovenography or computed tomography angiography and gross observations at surgery. All cases (both dogs and cats) had a highly consistent shunt that involved a distended gastrosplenic vein that communicated with the caudal vena cava at the level of the epiploic foramen via an anomalous left gastric vein. The morphology of the shunt type described appeared to be a result of an abnormal communication between the left gastric vein and the caudal vena cava and the subsequent development of preferential blood flow through an essentially normal portal venous system. The abnormal communication (shunt) was through the left gastric vein and not the splenic vein, as might have been expected. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2015 British Small Animal Veterinary Association.

  15. Measurement of Blood Flow in Arteriovenous Malformations before and after Embolization Using Arterial Spin Labeling

    PubMed Central

    Suazo, L.; Foerster, B.; Fermin, R.; Speckter, H.; Vilchez, C.; Oviedo, J.; Stoeter, P.

    2012-01-01

    Summary The assessment of shunt reduction after an embolization of an arteriovenous malformation (AVM) or fistula (AVF) from conventional angiography is often difficult and may be subjective. Here we present a completely non-invasive method using magnetic resonance imaging (MRI) to measure shunt reduction. Using pulsed arterial spin labeling (PASL), we determined the relative amount of signal attributed to the shunt over 1.75 s and 6 different slices covering the lesion. This amount of signal from the shunt was related to the total signal from all slices and measured before and after embolization. The method showed a fair agreement between the PASL results and the judgement from conventional angiography. In the case of a total or subtotal shunt occlusion, PASL showed a shunt reduction between 69% and 92%, whereas in minimal shunt reduction as judged by conventional angiography, the ASL result was –6% (indicating slightly increased flow) to 35% in a partially occluded vein of Galen aneurysm. The PASL method proved to be fairly reproducible (up to 2% deviation between three measurements without interventions). On conclusion, PASL is able to reliably measure the amount of shunt reduction achieved by embolization of AVMs and AVFs PMID:22440600

  16. Effects of isradipine and other calcium antagonists on arteriovenous-shunt flow in anesthetized rabbits and cats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hof, R.P.

    The effects of vasodilators on arteriovenous (AV)-shunt flow was investigated in anesthetized cats and rabbits, using the tracer microsphere method. In cats, the calcium antagonist isradipine reduced AV-shunt flow; verapamil showed a similar tendency and nicardipine was without effect. Dihydralazine strongly increased, but nitroglycerin and dipyridamole decreased AV-shunt flow. In rabbits, the effects of isradipine and verapamil were similar to those seen in cats. Sodium nitroprusside had no effect, whereas prazosin, minoxidil, and the potassium-channel activator cromakalim increased AV-shunt flow. The contrasting effects of drugs sharing the same mechanism of action suggest that target-tissue selectivity is more important than themore » mechanism of action. An increase of AV-shunt flow is unlikely to be beneficial but could be associated with a number of undesirable side effects. It might negatively affect migraine sufferers and, if AV-shunt dilatation shows no tolerance development, it represents an unnecessary hemodynamic burden for the heart.« less

  17. Hydrostatic and hydrodynamic considerations in shunted normal pressure hydrocephalus.

    PubMed

    de Jong, D A; Delwel, E J; Avezaat, C J

    2000-01-01

    Symptoms of overdrainage, a frequent complication following shunting procedures especially in patients with normal-pressure hydrocephalus (NPH), are presumed to be caused by siphoning: gravity-enhanced flow of cerebro spinal fluid (CSF) through shunts in upright position. A critical reappraisal of siphoning and overdrainage (OD) is presented considering the occurrence of subdural hygromas (SDH) encountered in a group of patients shunted for NPH. The patients participated in the multicentre Dutch NPH study: 101 NPH patients were randomised for treatment with shunts with low or medium-high working pressure. Treatment with shunts with low working pressure resulted in an increased incidence of SDH (iSDH). Current physiological concepts of overdrainage are discussed and criticised. A new theory is presented on the basis of general physiological considerations. The theoretical model proposed yields a revised explanation for the origin of extremely low ventricular pressure in the upright position found with overdrainage. The efficacy of siphoning-preventing shunts and subtemporal decompression is explored in the light of the proposed theory.

  18. Neonatal Brain Hemorrhage (NBH) of Prematurity: Translational Mechanisms of the Vascular-Neural Network

    PubMed Central

    Lekic, Tim; Klebe, Damon; Poblete, Roy; Krafft, Paul R.; Rolland, William B.; Tang, Jiping; Zhang, John H.

    2015-01-01

    Neonatal brain hemorrhage (NBH) of prematurity is an unfortunate consequence of preterm birth. Complications result in shunt dependence and long-term structural changes such as post-hemorrhagic hydrocephalus, periventricular leukomalacia, gliosis, and neurological dysfunction. Several animal models are available to study this condition, and many basic mechanisms, etiological factors, and outcome consequences, are becoming understood. NBH is an important clinical condition, of which treatment may potentially circumvent shunt complication, and improve functional recovery (cerebral palsy, and cognitive impairments). This review highlights key pathophysiological findings of the neonatal vascular-neural network in the context of molecular mechanisms targeting the post-hemorrhagic hydrocephalus affecting this vulnerable infant population. PMID:25620100

  19. Laparoscopic correction of congenital portosystemic shunt in children.

    PubMed

    Kimura, Takuya; Soh, Hideki; Hasegawa, Toshimichi; Sasaki, Takashi; Kuroda, Seika; Yuri, Etani; Tomoda, Kaname; Fukuzawa, Masahiro

    2004-10-01

    Congenital portosystemic shunt is a rare clinical entity that may progress to jaundice, severe encephalopathy, and pulmonary hypertension and require surgical correction or coil embolization. We present a novel approach to the management of children with congenital portosystemic shunt by means of a minimally invasive surgical technique. Congenital portosystemic shunts were identified between the superior mesenteric vein and inferior vena cava in case 1 and between the splenic vein and left renal vein in case 2. Both of them were successfully ligated by laparoscopic approach, and catheters were subsequently replaced to monitor portal venous pressure. The patients tolerated the procedure well, and short-term results were excellent. Laparoscopic ligation of congenital portosystemic shunt is technically feasible and less invasive to the management of patients with congenital portosystemic shunts, preventing late onset, life-threatening complications.

  20. Shunting outcomes in posthemorrhagic hydrocephalus: results of a Hydrocephalus Clinical Research Network prospective cohort study.

    PubMed

    Wellons, John C; Shannon, Chevis N; Holubkov, Richard; Riva-Cambrin, Jay; Kulkarni, Abhaya V; Limbrick, David D; Whitehead, William; Browd, Samuel; Rozzelle, Curtis; Simon, Tamara D; Tamber, Mandeep S; Oakes, W Jerry; Drake, James; Luerssen, Thomas G; Kestle, John

    2017-07-01

    OBJECTIVE Previous Hydrocephalus Clinical Research Network (HCRN) retrospective studies have shown a 15% difference in rates of conversion to permanent shunts with the use of ventriculosubgaleal shunts (VSGSs) versus ventricular reservoirs (VRs) as temporization procedures in the treatment of hydrocephalus due to high-grade intraventricular hemorrhage (IVH) of prematurity. Further research in the same study line revealed a strong influence of center-specific decision-making on shunt outcomes. The primary goal of this prospective study was to standardize decision-making across centers to determine true procedural superiority, if any, of VSGS versus VR as a temporization procedure in high-grade IVH of prematurity. METHODS The HCRN conducted a prospective cohort study across 6 centers with an approximate 1.5- to 3-year accrual period (depending on center) followed by 6 months of follow-up. Infants with premature birth, who weighed less than 1500 g, had Grade 3 or 4 IVH of prematurity, and had more than 72 hours of life expectancy were included in the study. Based on a priori consensus, decisions were standardized regarding the timing of initial surgical treatment, upfront shunt versus temporization procedure (VR or VSGS), and when to convert a VR or VSGS to a permanent shunt. Physical examination assessment and surgical technique were also standardized. The primary outcome was the proportion of infants who underwent conversion to a permanent shunt. The major secondary outcomes of interest included infection and other complication rates. RESULTS One hundred forty-five premature infants were enrolled and met criteria for analysis. Using the standardized decision rubrics, 28 infants never reached the threshold for treatment, 11 initially received permanent shunts, 4 were initially treated with endoscopic third ventriculostomy (ETV), and 102 underwent a temporization procedure (36 with VSGSs and 66 with VRs). The 2 temporization cohorts were similar in terms of sex, race, IVH grade, head (orbitofrontal) circumference, and ventricular size at temporization. There were statistically significant differences noted between groups in gestational age, birth weight, and bilaterality of clot burden that were controlled for in post hoc analysis. By Kaplan-Meier analysis, the 180-day rates of conversion to permanent shunts were 63.5% for VSGS and 74.0% for VR (p = 0.36, log-rank test). The infection rate for VSGS was 14% (5/36) and for VR was 17% (11/66; p = 0.71). The overall compliance rate with the standardized decision rubrics was noted to be 90% for all surgeons. CONCLUSIONS A standardized protocol was instituted across all centers of the HCRN. Compliance was high. Choice of temporization techniques in premature infants with IVH does not appear to influence rates of conversion to permanent ventricular CSF diversion. Once management decisions and surgical techniques are standardized across HCRN sites, thus minimizing center effect, the observed difference in conversion rates between VSGSs and VRs is mitigated.

  1. MRI safety of a programmable shunt assistant at 3 and 7 Tesla.

    PubMed

    Mirzayan, M Javad; Klinge, Petra M; Samii, Madjid; Goetz, Friedrich; Krauss, Joachim K

    2012-06-01

    Several new shunt technologies have been developed to optimize hydrocephalus treatment within the past few years. Overdrainage, however, still remains an unresolved problem. One new technology which may reduce the frequency of this complication is the use of a programmable shunt assistant (proSA). Inactive in a horizontal position, it impedes CSF flow in a vertical position according to a prescribed pressure level ranging from 0 to 40 cm H(2)O. We exposed the proSA valve in an ex vivo protocol to MR systems operating at 3 and 7 Tesla to investigate its MRI safety. Following 3 Tesla exposure, no changes in valve settings were noted. Adjustment to any pressure level was possible thereafter. The mean deflection angle was 23 ± 3°. After exposure to 7 Tesla, however, there were unintended pressure changes, and the mechanism for further adjustment of the valves even disintegrated. According to the results of this study, proSA is safe with heteropolar vertical magnet alignment at 3 Tesla. Following 7 Tesla exposure, the valves lost their functional capability.

  2. Pulmonary physiology during pulmonary embolism.

    PubMed

    Elliott, C G

    1992-04-01

    Acute pulmonary thromboembolism produces a number of pathophysiologic derangements of pulmonary function. Foremost among these alterations is increased pulmonary vascular resistance. For patients without preexistent cardiopulmonary disease, increased pulmonary vascular resistance is directly related to the degree of vascular obstruction demonstrated on the pulmonary arteriogram. Vasoconstriction, either reflexly or biochemically mediated, may contribute to increased pulmonary vascular resistance. Acute pulmonary thromboembolism also disturbs matching of ventilation and blood flow. Consequently, some lung units are overventilated relative to perfusion (increased dead space), while other lung units are underventilated relative to perfusion (venous admixture). True right-to-left shunting of mixed venous blood can occur through the lungs (intrapulmonary shunt) or across the atrial septum (intracardiac shunt). In addition, abnormalities of pulmonary gas exchange (carbon monoxide transfer), pulmonary compliance and airway resistance, and ventilatory control may accompany pulmonary embolism. Thrombolytic therapy can reverse the hemodynamic derangements of acute pulmonary thromboembolism more rapidly than anticoagulant therapy. Limited data suggest a sustained benefit of thrombolytic treatment on the pathophysiologic alterations of pulmonary vascular resistance and pulmonary gas exchange produced by acute pulmonary emboli.

  3. Evaluation of Blalock-Taussig shunts in newborns: value of oblique MRI planes.

    PubMed

    Kastler, B; Livolsi, A; Germain, P; Zöllner, G; Dietemann, J L

    1991-01-01

    Eight infants with systemic-pulmonary Blalock-Taussig shunts were evaluated by spin-echo ECG-gated MRI. Contrary to Echocardiography, MRI using coronal oblique projections successfully visualized all palliative shunts entirely in one single plane (including one carried out on a right aberrant subclavian artery). MRI allowed assessment of size, course and patency of the shunt, including pulmonary and subclavian insertion. The proximal portion of the pulmonary and subclavian arteries were also visualized. We conclude that MRI with axial scans completed by coronal oblique planes is a promising, non invasive method for imaging the anatomical features of Blalock-Taussig shunts.

  4. [The use of labelled albumin microspheres in the study of arteriovenous shunting in varicosities of the lower limbs (author's transl)].

    PubMed

    Serise, J M; Le Héron, D; Le Héron, G; Bonnet, A; Busquet, J; Basse-Cathalinat, B; Tingaud, R

    1982-01-01

    The greater proportion of oxygen in the blood circulating in veins of the lower limbs bought to attention the possibility of pre-capillary arteriovenous shunting. The intra-arteriel injection of Technetium labelled serum albumin microspheres enables one to quantify arteriovenous shunts greater than 25 microns. The authors made a comparative study of arterio-venous shunting by blood gases analysis and isotopic techniques in twenty patients. The results seem to deny the existence of arteriovenous shunts in the genesis of essential varicose veins in the lower limb.

  5. Decreased head circumference in shunt-treated compared with healthy children.

    PubMed

    Nilsson, Daniel; Svensson, Johanna; Korkmaz, Betül A; Nelvig, Helena; Tisell, Magnus

    2013-11-01

    In this study, the authors' goal was to compare head circumference in hydrocephalic children during the first 4 years of ventriculoperitoneal (VP) shunt treatment with data on healthy children and to investigate predictors of skull growth in children with a VP shunt. Children from western Sweden treated for hydrocephalus with an initial VP shunt insertion performed between 2001 and 2006 who were younger than 12 months of age at the time of surgery were included. Children with major brain malformations, craniofacial syndromes, large cysts, and tumors were excluded. Head circumference, weight, and height at 9 defined ages up to 4 years were obtained and compared with data from a reference population of 3650 healthy children using the standard deviation score (SDS). Predictors (length, weight, etiology of hydrocephalus, valve type, number of revisions, valve setting, number of adjustments, and time of first surgery) for head circumference SDS and changes in head circumference SDS from shunt insertion at 1 year to last measurement were analyzed using bivariate and multiple linear regression analysis. Fifty children were included. The mean SDSs for head circumference in shunt-treated compared with healthy children were 1.95 ± 2.50 at shunt insertion (p < 0.001, n = 44), 0.38 ± 1.97 at 1 year (p = 0.27, n = 33), -0.96 ± 2.05 at 2 years (p = 0.046, n = 21), -1.39 ± 2.25 at 3 years (p = 0.026, n = 16), and 0.63 ± 3.34 at 4 years (p = 0.73, n = 4). Significant predictors for low head circumference SDS at 1 year of age were low weight (p = 0.002) and short height (p = 0.022) and at last measurement low weight (p < 0.0001), short height (p = 0.002), and 1-4 shunt revisions (p = 0.034). A significant predictor for change in head circumference SDS from shunt insertion to 1 year of age was the number of shunt valve revisions (p = 0.04) and at last measurement an etiology of intraventricular hemorrhage (p = 0.0058). Shunt-treated children have smaller head circumferences at 2 and 3 years of age than healthy children. Low weight, short height, etiology of intraventricular hemorrhage, and frequent shunt valve revisions are predictors for decreased head circumference. Prospective, randomized studies comparing skull growth using fixed and adjustable pressure-regulated shunt valves and flow-regulated valves are needed.

  6. Current treatment of normal-pressure hydrocephalus: comparison of flow-regulated and differential-pressure shunt valves.

    PubMed

    Weiner, H L; Constantini, S; Cohen, H; Wisoff, J H

    1995-11-01

    FROM THE RECORDS of approximately 1500 shunt operations performed between 1987 and 1992, we identified 37 adults between ages 38 and 86 years (mean, 70 yr) with the normal-pressure hydrocephalus (NPH) syndrome who underwent surgery by a single surgeon. Since 1990, we have routinely used a flow-regulated shunt system (Orbis-Sigma valve [OSV]; Cordis Corporation, Miami, FL) in these patients. In this study, we compared the OSV system with conventional differential-pressure (DP) shunt systems uniformly used before 1990. This series (n = 37) consisted of 62% men (n = 23) and 38% women (n = 14). We excluded all patients with hydrocephalus associated with central nervous system neoplasms, intracerebral hemorrhage, or trauma as well those with radiographically documented late-onset aqueductal stenosis. All patients presented with the NPH clinical syndrome, chiefly with magnetic gait. In addition, 75% of patients experienced cognitive loss and 59% experienced urinary incontinence. The mean duration of preoperative symptoms was 35 months (range, 7-120 mo). Eight patients (22%) had undergone previous shunting procedures before referral to our service. A total of 89 shunt operations were performed in the 37 patients. Using actuarial methods and controlling for a history of prior shunt surgery, we found no significant difference in the time to initial malfunction (shunt survival) between the OSV and the DP shunts. There were three subdural hematomas and one infection in the OSV group compared with no complications in the DP valve group (P = 0.11). Thirty-six patients were available for follow-up, at a mean of 14 months after surgery. Nearly 90% of all patients experienced improvement in gait after shunting, regardless of the valve system that was used. There was one unrelated death. Realizing the limitations of a retrospective analysis and on the basis of the limited number of patients in this study, we conclude that using actuarial methods, we found no significant difference in shunt survival when comparing the OSV with the standard DP valve shunt systems with antisiphon devices in patients with NPH. Contrary to previous reports, the OSV is not free of overdrainage complications. Most patients (89%) with the NPH syndrome who primarily presented with gait disorder experienced significant improvement in gait after either OSV or DP shunting procedures when selected for surgery on the basis of the clinical syndrome and confirmatory radiographic data.

  7. Predisposing Factors for Spontaneous Closure of Congenital Portosystemic Shunts.

    PubMed

    Paganelli, Massimiliano; Lipsich, José E; Sciveres, Marco; Alvarez, Fernando

    2015-10-01

    In a review of 382 cases of congenital portosystemic shunt, we found that presentation with neonatal cholestasis strongly predicts spontaneous closure of intrahepatic shunts (OR 8.3, 95% CI 3.4-20.2). Spontaneous closure before the 24th month of age is more likely for distal or multiple shunts, but rare for patent ductus venosus. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. 21 CFR 886.3920 - Aqueous shunt.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) Classification. Class II. The special controls for this device are FDA's: (1) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical Devices—Part I: Evaluation and Testing,’ ” (2) “510(k) Sterility...

  9. 21 CFR 886.3920 - Aqueous shunt.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Classification. Class II. The special controls for this device are FDA's: (1) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical Devices—Part I: Evaluation and Testing,’ ” (2) “510(k) Sterility...

  10. 21 CFR 886.3920 - Aqueous shunt.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) Classification. Class II. The special controls for this device are FDA's: (1) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical Devices—Part I: Evaluation and Testing,’ ” (2) “510(k) Sterility...

  11. 21 CFR 886.3920 - Aqueous shunt.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Classification. Class II. The special controls for this device are FDA's: (1) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical Devices—Part I: Evaluation and Testing,’ ” (2) “510(k) Sterility...

  12. 21 CFR 886.3920 - Aqueous shunt.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Classification. Class II. The special controls for this device are FDA's: (1) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical Devices—Part I: Evaluation and Testing,’ ” (2) “510(k) Sterility...

  13. Shunt-dependent hydrocephalus: management style among members of the American Society of Pediatric Neurosurgeons.

    PubMed

    Kraemer, Mark R; Sandoval-Garcia, Carolina; Bragg, Taryn; Iskandar, Bermans J

    2017-09-01

    OBJECTIVE The authors conducted a survey to evaluate differences in the understanding and management of shunt-dependent hydrocephalus among members of the American Society of Pediatric Neurosurgeons (ASPN). METHODS Surveys were sent to all 204 active ASPN members in September 2014. One hundred thirty responses were received, representing a 64% response rate. Respondents were asked 13 multiple-choice and free-response questions regarding 4 fundamental problems encountered in shunted-hydrocephalus management: shunt malfunction, chronic cerebrospinal fluid (CSF) overdrainage, chronic headaches, and slit ventricle syndrome (SVS). RESULTS Respondents agreed that shunt malfunction occurs most often as the result of ventricular catheter obstruction. Despite contrary evidence in the literature, most respondents (66%) also believed that choroid plexus is the tissue most often found in obstructed proximal catheters. However, free-text responses revealed that the respondents' understanding of the underlying pathophysiology of shunt obstruction was highly variable and included growth, migration, or adherence of choroid plexus, CSF debris, catheter position, inflammatory processes, and CSF overdrainage. Most respondents considered chronic CSF overdrainage to be a rare complication of shunting in their practice and reported wide variation in treatment protocols. Moreover, despite a lack of evidence in the literature, most respondents attributed chronic headaches in shunt patients to medical reasons (for example, migraines, tension). Accordingly, most respondents managed headaches with reassurance and/or referral to pain clinics. Lastly, there were variable opinions on the etiology of slit ventricle syndrome (SVS), which included early shunting, chronic overdrainage, and/or loss of brain compliance. Beyond shunt revision, respondents reported divergent SVS treatment preferences. CONCLUSIONS The survey shows that there is wide variability in the understanding and management of shunt-dependent hydrocephalus and its complications. Such discrepancies appear to be derived partly from inconsistent familiarity with existing literature but especially from a paucity of high-quality publications.

  14. Treatment options for Dandy-Walker malformation.

    PubMed

    Mohanty, Aaron; Biswas, Arundhati; Satish, Satyanarayana; Praharaj, Shanti Shankar; Sastry, Kolluri V R

    2006-11-01

    The aim of this study was to assess the efficacy of various treatment options available for children with Dandy-Walker malformation (DWM) and to evaluate the role of endoscopic procedures in the treatment of this disorder. The authors conducted a retrospective review of 72 children who underwent surgical treatment for DWM during a 16-year period. All patients underwent computed tomography scanning, and 26 underwent magnetic resonance (MR) imaging. The initial surgical treatment included ventriculoperitoneal (VP) shunt placement in 21 patients, cystoperitoneal (CP) shunt placement in 24, and combined VP and CP shunt insertion in three. Twenty-one patients underwent endoscopic procedures (endoscopic third ventriculostomy [ETV] alone in 16 patients, ETV with aqueductal stent placement in three, and ETV with fenestration of the occluding membrane in two). Three patients underwent membrane excision via a posterior fossa craniectomy. In the 26 patients who had undergone preoperative MR imaging, aqueductal patency was noted in 23 and aqueductal obstruction in three. These three patients underwent placement of a stent from the third ventricle to the posterior fossa cyst in addition to the ETV procedure. During the follow-up period, 12 patients with a CP shunt and four with a VP shunt experienced shunt malfunctions that required revision. Four patients with a CP shunt also required placement of a VP shunt. In addition, five of the 21 ETVs failed, requiring VP shunt insertion. A reduction in ventricle size noted on postoperative images occurred more frequently in patients with a VP shunt, whereas a reduction in cyst size was more appreciable in patients with a CP shunt. Successful ETV resulted in a slight decrease in ventricle size and varying degrees of reduction in cyst size. Endoscopic procedures may be considered an acceptable alternative in children with DWM. The authors propose a treatment protocol based on preoperative MR imaging findings of associated aqueductal stenosis.

  15. Laparoscopic treatment of abdominal complications following ventriculoperitoneal shunt

    PubMed Central

    Grigorean, VT; Onose, G; Popescu, M; Strambu, V; Sandu, AM

    2009-01-01

    The aim of this study is the evaluation of laparoscopic treatment in abdominal complications following ventriculoperitoneal (VP) shunt. Methods: We report a retrospective study including 17 patients with abdominal complications secondary to VP shunt for hydrocephalus, laparoscopically treated in our department, between 2000 and 2007. Results: Patients' age ranged from 1 to 72 years old (mean age 25.8 years old). Male: female ratio was 1.4. Abdominal complications encountered were: shunt disconnection with intraperitoneal distal catheter migration 47.05% (8/17), infections 23.52% (4/17) such as abscesses and peritonitis, pseudocysts 11.76% (2/17), CSF ascites 5.88% (1/17), inguinal hernia 5.88% (1/17), and shunt malfunction due to excessive length of intraperitoneal tube 5.88% (1/17). Free–disease interval varies from 1 day to 21 years, depending on the type of complication, short in peritoneal irritation syndrome and abscesses (days) and long in ascites, pseudocysts(months– years). Laparoscopic treatment was: extraction of the foreign body in shunt disconnection with intraperitoneal distal catheter migration, evacuation, debridement, lavage and drainage for pseudocysts, abscess and peritonitis, shortening of the tube in shunt malfunction due to excessive length of intraperitoneal tube a nd hernioraphy. One diagnostic laparoscopy was performed in a peritoneal irritation syndrome, which found only CSF ascites. There were no conversions to open surgery. The overall mortality was of 5.88% and postoperative morbidity was of 11.76%. In 7 patients operated for abscesses, peritonitis, pseudocysts, and CSF ascites the shunting system was converted in to a ventriculocardiac shunt. Conclusions: Abdominal complication following VP shunt can be successfully performed laparoscopically. Abdominal surgery required, in selected cases, the repositioning of the distal catheter, frequently as a ventriculocardiac shunt. There are abdominal complications with no indication of surgery, like peritoneal irritation syndrome and CSF ascites. Free– disease interval varies from days (peritoneal irritation syndrome, abscesses) to month–years (pseudocyst, ascites), according to type of complication. PMID:20108757

  16. Transjugular intrahepatic portosystemic shunt: impact on systemic hemodynamics and renal and cardiac function in patients with cirrhosis.

    PubMed

    Busk, Troels M; Bendtsen, Flemming; Poulsen, Jørgen H; Clemmesen, Jens O; Larsen, Fin S; Goetze, Jens P; Iversen, Jens S; Jensen, Magnus T; Møgelvang, Rasmus; Pedersen, Erling B; Bech, Jesper N; Møller, Søren

    2018-02-01

    Transjugular intrahepatic portosystemic shunt (TIPS) alleviates portal hypertension and possibly increases central blood volume (CBV). Moreover, renal function often improves; however, its effects on cardiac function are unclear. The aims of our study were to examine the effects of TIPS on hemodynamics and renal and cardiac function in patients with cirrhosis. In 25 cirrhotic patients, we analyzed systemic, cardiac, and splanchnic hemodynamics by catheterization of the liver veins and right heart chambers before and 1 wk after TIPS. Additionally, we measured renal and cardiac markers and performed advanced echocardiography before, 1 wk after, and 4 mo after TIPS. CBV increased significantly after TIPS (+4.6%, P < 0.05). Cardiac output (CO) increased (+15.3%, P < 0.005) due to an increase in stroke volume (SV) (+11.1%, P < 0.005), whereas heart rate (HR) was initially unchanged. Cardiopulmonary pressures increased after TIPS, whereas copeptin, a marker of vasopressin, decreased (-18%, P < 0.005) and proatrial natriuretic peptide increased (+52%, P < 0.0005) 1 wk after TIPS and returned to baseline 4 mo after TIPS. Plasma neutrophil gelatinase-associated lipocalin, renin, aldosterone, and serum creatinine decreased after TIPS (-36%, P < 0.005; -65%, P < 0.05; -90%, P < 0.005; and -13%, P < 0.005, respectively). Echocardiography revealed subtle changes in cardiac function after TIPS, although these were within the normal range. TIPS increases CBV by increasing CO and SV, whereas HR is initially unaltered. These results indicate an inability to increase the heart rate in response to a hemodynamic challenge that only partially increases CBV after TIPS. These changes, however, are sufficient for improving renal function. NEW & NOTEWORTHY For the first time, we have combined advanced techniques to study the integrated effects of transjugular intrahepatic portosystemic shunt (TIPS) in cirrhosis. We showed that TIPS increases central blood volume (CBV) through improved cardiac inotropy. Advanced echocardiography demonstrated that myocardial function was unaffected by the dramatic increase in preload after TIPS. Finally, renal function improved due to the increase in CBV. Recognition of these physiological changes significantly contributes to our clinical understanding of TIPS.

  17. Hydrogen sulfide upregulates heme oxygenase-1 expression in rats with volume overload-induced heart failure

    PubMed Central

    ZHANG, CHAO-YING; LI, XIAO-HUI; ZHANG, TING; FU, JIN; CUI, XIAO-DAI

    2013-01-01

    The present study investigated the role of hydrogen sulfide (H2S), a novel gaseous transmitter, in chronic heart failure (CHF) induced by left-to-right shunt, leading to volume overload. Thirty male Sprague-Dawley rats were randomly divided into four groups: the shunt group, the sham group, the shunt + sodium hydrosulfide (NaHS) group and the sham + NaHS group. CHF was induced in the rats by abdominal aorta-inferior vena cava shunt operation. Rats in the shunt + NaHS and sham + NaHS groups were injected intraperitoneally with NaHS (H2S donor). Haemodynamic parameters were measured 8 weeks after surgery. In addition, left ventricular heme oxygenase (HO)-1 mRNA expression was measured by real-time PCR. Protein expression of HO-1 was evaluated by western blot analysis. Eight weeks after surgery, compared to the sham group, the left ventricular systolic pressure (LVSP) and left ventricular peak rate of contraction and relaxation (LV±dp/dtmax) were significantly reduced; the left ventricular end-diastolic pressure (LVEDP) was significantly increased in the shunt group (all P<0.05). However, NaHS increased LVSP and LV±dp/dtmax (all P<0.05) and decreased LVEDP (P<0.05). Protein expression of HO-1 was significantly decreased in the shunt group compared to that in the sham group (P<0.05). NaHS increased protein expression of HO-1 compared to that in the shunt group (P<0.05). HO-1 mRNA expression was significantly increased in the shunt + NaHS group compared to that in the shunt group (P<0.01). The present study demonstrated that H2S may play a protective role in volume overload-induced CHF by upregulating protein and mRNA expression of HO-1. PMID:24648967

  18. Staged Transcatheter Treatment of Portal Hypoplasia and Congenital Portosystemic Shunts in Children

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bruckheimer, Elchanan, E-mail: elchananb@bezeqint.net; Dagan, Tamir; Atar, Eli

    2013-12-15

    Purpose: Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Methods: Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by {approx}50 %. Recatheterization was performed approximately 3 months later. If the portal pressuremore » was below 18 mmHg and vessels had developed, the shunt was closed with a device. Results: Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5-13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2-8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 {+-} 11.3 to 10.8 {+-} 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 {+-} 0.5 to 4.0 {+-} 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 {+-} 53.6 to 65.7 {+-} 9.6 {mu}mol/L; p = 0.002) with no complications. Conclusion: Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia.« less

  19. Does hepatic steatosis have an impact on the short term hepatic response after complete attenuation of congenital extrahepatic portosystemic shunts? A prospective study of 20 dogs.

    PubMed

    Hunt, Geraldine B; Luff, Jennifer; Daniel, Leticia; Zwingenberger, Allison

    2014-11-01

    To evaluate the relationship between hepatic steatosis and increase in liver size and resolution of shunting after surgical attenuation of congenital extrahepatic portosystemic shunts in dogs. Prospective study. Dogs (n = 20) with congenital extrahepatic portosystemic shunts. Shunts were attenuated using ameroid ring constrictors. Portal blood flow and liver volume were evaluated using computed tomography before and ≥8 weeks after surgery. Hepatic steatosis was quantified by stereological point counting of lipid droplets and lipogranulomas (LG) in liver biopsies stained with Oil-red-O. Associations between steatosis and preoperative liver volume, liver growth after surgery, and development of acquired shunts were evaluated. Acquired shunts developed in 2 dogs (10%). Dogs with larger preoperative liver volumes relative to bodyweight had fewer lipid droplets per tissue point (P = .019). LG per tissue point were significantly associated with age: 0.019 ± 0.06 for dogs <12 months versus 0.25 ± 0.49 for dogs >12 months (P = .007). There was a significant positive association between liver growth after surgery and the number of LG/month of age in dogs >12 months (P = .003). There was no association between steatosis, presence of macrosteatosis, the number of LG or development of acquired shunts. This preliminary study suggests that the presence of hepatic lipidosis and LG has no demonstrable effect on development of acquired shunts or the magnitude of increase in liver volume after attenuation of congenital extrahepatic portosystemic shunts in dogs. © Copyright 2014 by The American College of Veterinary Surgeons.

  20. Staged transcatheter treatment of portal hypoplasia and congenital portosystemic shunts in children.

    PubMed

    Bruckheimer, Elchanan; Dagan, Tamir; Atar, Eli; Schwartz, Michael; Kachko, Ludmila; Superina, Riccardo; Amir, Gabriel; Shapiro, Rivka; Birk, Einat

    2013-12-01

    Congenital portosystemic shunts (CPSS) with portal venous hypoplasia cause hyperammonemia. Acute shunt closure results in portal hypertension. A transcatheter method of staged shunt reduction to afford growth of portal vessels followed by shunt closure is reported. Pressure measurements and angiography in the CPSS or superior mesenteric artery (SMA) during temporary occlusion of the shunt were performed. If vessels were diminutive and the pressure was above 18 mmHg, a staged approach was performed, which included implantation of a tailored reducing stent to reduce shunt diameter by ~50 %. Recatheterization was performed approximately 3 months later. If the portal pressure was below 18 mmHg and vessels had developed, the shunt was closed with a device. Six patients (5 boys, 1 girl) with a median age of 3.3 (range 0.5-13) years had CPSS portal venous hypoplasia and hyperammonemia. Five patients underwent staged closure. One patient tolerated acute closure. One patient required surgical shunt banding because a reducing stent could not be positioned. At median follow-up of 3.8 (range 2.2-8.4) years, a total of 21 procedures (20 transcatheter, 1 surgical) were performed. In all patients, the shunt was closed with a significant reduction in portal pressure (27.7 ± 11.3 to 10.8 ± 1.8 mmHg; p = 0.016), significant growth of the portal vessels (0.8 ± 0.5 to 4.0 ± 2.4 mm; p = 0.037), and normalization of ammonia levels (202.1 ± 53.6 to 65.7 ± 9.6 μmol/L; p = 0.002) with no complications. Staged CPSS closure is effective in causing portal vessel growth and treating hyperammonemia.

  1. Congenital portosystemic shunts in children: a new anatomical classification correlated with surgical strategy.

    PubMed

    Blanc, Thomas; Guerin, Florent; Franchi-Abella, Stéphanie; Jacquemin, Emmanuel; Pariente, Danièle; Soubrane, Olivier; Branchereau, Sophie; Gauthier, Frédéric

    2014-07-01

    To propose an anatomical classification of congenital portosystemic shunts (CPSs) correlating with conservative surgery. CPSs entail a risk of life-threatening complications because of poor portal inflow, which may be prevented or cured by their closure. Current classifications based on portal origin of the shunt are not helpful for planning conservative surgery. Twenty-three patients who underwent at least 1 surgical procedure to close the CPSs were included in this retrospective study (1997-2012). We designed a classification according to the ending of the shunt in the caval system. We analyzed the results and outcomes of surgery according to this classification. Two patients had an extrahepatic portosystemic shunt, 17 had a portacaval shunt [subdivided in 5 end-to-side-like portal-caval, 7 side-to-side-like portal-caval, and 5 H-shaped (H-type portal-caval)], 2 had portal-to-hepatic vein shunts (portohepatic), and 2 had a persistent ductus venosus. All extrahepatic portosystemic shunts, H-type portal-caval, portohepatic, and patent ductus venosus patients had a successful 1-stage ligation. All 5 end-to-side-like portal-caval patients had a threadlike intrahepatic portal venous system; a 2-stage complete closure was successfully achieved for 4 and a partial closure for 1. The first 2 side-to-side-like portal-caval patients had a successful 2-stage closure whereas the 5 others had a 1-stage longitudinal caval partition. All patients are alive and none needed a liver transplantation. Our classification correlates the anatomy of CPSs and the surgical strategy: outcomes are good provided end-to-side-like portal-caval shunts patients have a 2-stage closure, side-to-side portal-caval shunts patients have a 1-stage caval partition, and the others have a 1-stage ligation.

  2. Short ORF-Dependent Ribosome Shunting Operates in an RNA Picorna-Like Virus and a DNA Pararetrovirus that Cause Rice Tungro Disease

    PubMed Central

    Pooggin, Mikhail M.; Rajeswaran, Rajendran; Schepetilnikov, Mikhail V.; Ryabova, Lyubov A.

    2012-01-01

    Rice tungro disease is caused by synergistic interaction of an RNA picorna-like virus Rice tungro spherical virus (RTSV) and a DNA pararetrovirus Rice tungro bacilliform virus (RTBV). It is spread by insects owing to an RTSV-encoded transmission factor. RTBV has evolved a ribosome shunt mechanism to initiate translation of its pregenomic RNA having a long and highly structured leader. We found that a long leader of RTSV genomic RNA remarkably resembles the RTBV leader: both contain several short ORFs (sORFs) and potentially fold into a large stem-loop structure with the first sORF terminating in front of the stem basal helix. Using translation assays in rice protoplasts and wheat germ extracts, we show that, like in RTBV, both initiation and proper termination of the first sORF translation in front of the stem are required for shunt-mediated translation of a reporter ORF placed downstream of the RTSV leader. The base pairing that forms the basal helix is required for shunting, but its sequence can be varied. Shunt efficiency in RTSV is lower than in RTBV. But in addition to shunting the RTSV leader sequence allows relatively efficient linear ribosome migration, which also contributes to translation initiation downstream of the leader. We conclude that RTSV and RTBV have developed a similar, sORF-dependent shunt mechanism possibly to adapt to the host translation system and/or coordinate their life cycles. Given that sORF-dependent shunting also operates in a pararetrovirus Cauliflower mosaic virus and likely in other pararetroviruses that possess a conserved shunt configuration in their leaders it is tempting to propose that RTSV may have acquired shunt cis-elements from RTBV during their co-existence. PMID:22396650

  3. Surgical management of hydrocephalus secondary to intraventricular hemorrhage in the preterm infant.

    PubMed

    Christian, Eisha A; Melamed, Edward F; Peck, Edwin; Krieger, Mark D; McComb, J Gordon

    2016-03-01

    OBJECT Posthemorrhagic hydrocephalus (PHH) in the preterm infant remains a major neurological complication of prematurity. The authors first described insertion of a specially designed low-profile subcutaneous ventricular catheter reservoir for temporary management of hydrocephalus in 1983. This report presents the follow-up experience with the surgical management of PHH in this population and describes outcomes both in infants who were stable for permanent shunt insertion and those initially temporized with a ventricular reservoir (VR) prior to permanent ventriculoperitoneal (VP)/ventriculoatrial (VA) shunt placement. METHODS A retrospective review was undertaken of the medical records of all premature infants surgically treated for posthemorrhagic hydrocephalus (PHH) between 1997 and 2012 at Children's Hospital Los Angeles. RESULTS Over 14 years, 91 preterm infants with PHH were identified. Fifty neonates received temporizing measures via a VR that was serially tapped for varying time periods. For the remaining 41 premature infants, VP/VA shunt placement was the first procedure. Patients with a temporizing measure as their initial procedure had undergone CSF diversion significantly earlier in life than those who had permanent shunting as the initial procedure (29 vs 56 days after birth, p < 0.01). Of the infants with a VR as their initial procedure, 5/50 (10%) did not undergo subsequent VP/VA shunt placement. The number of shunt revisions and the rates of loculated hydrocephalus and shunt infection did not statistically differ between the 2 groups. CONCLUSIONS Patients with initial VR insertion as a temporizing measure received a CSF diversion procedure significantly earlier than those who received a permanent shunt as their initial procedure. Otherwise, the outcomes with regard to shunt revisions, loculated hydrocephalus, and shunt infection were not different for the 2 groups.

  4. Measurement of peak CSF flow velocity at cerebral aqueduct, before and after lumbar CSF drainage, by use of phase-contrast MRI: utility in the management of idiopathic normal pressure hydrocephalus.

    PubMed

    Sharma, Ashwani Kumar; Gaikwad, Shailesh; Gupta, Vipul; Garg, Ajay; Mishra, Nalini K

    2008-04-01

    Since it was first described, normal pressure hydrocephalus (NPH) and its treatment by means of cerebrospinal fluid (CSF) shunting have been the focus of much investigation. Whatever be the cause of NPH, it has been hypothesized that in this disease there occurs decreased arterial expansion and an increased brain expansion leading to increased transmantle pressure. We cannot measure the latter, but fortunately the effect of these changes (increased peak flow velocity through the aqueduct) can be quantified with cine phase-contrast magnetic resonance imaging (MRI). This investigation was thus undertaken to characterize and measure CSF peak flow velocity at the level of the aqueduct, before and after lumbar CSF drainage, by means of a phase-contrast cine MRI and determine its role in selecting cases for shunt surgery. 37 patients with clinically suspected NPH were included in the study. Changes in the hyperdynamic peak CSF flow velocity with 50 ml lumbar CSF drainage (mimicking shunt) were evaluated in them for considering shunt surgery. 14 out of 15 patients who were recommended for shunt surgery, based on changes peak flow velocity after lumbar CSF drainage, improved after shunt surgery. None of the cases which were not recommended for shunt surgery, based on changes in CSF peak flow velocity after lumbar CSF drainage, improved after shunt surgery (2 out of 22 cases). The study concluded that the phase-contrast MR imaging, done before and after CSF drainage, is a sensitive method to support the clinical diagnosis of normal pressure hydrocephalus, selecting patients of NPH who are likely to benefit from shunt surgery, and to select patients of NPH who are not likely to benefit from shunt surgery.

  5. An Unusual Complication of Ventriculoperitoneal Shunt: Urinary Bladder Stone Case Report and Literature Review.

    PubMed

    Xu, Songtao; Sheng, Weixin; Qiu, Yufa; Wang, Jianguo

    2016-01-01

    Ventriculoperitoneal (V-P) shunt surgery is the most common technique used for the treatment of hydrocephalus. The migration of ventriculoperitoneal shunt to the bladder is rare. Only two cases have been previously reported in the literature. We report on a 38-year-old male who had hydrocephalus and V-P shunt for 12 years. Two years ago, he found himself with recurrent urinary tract infections, haematuria and urges incontinence, and then he was diagnosed with bladder perforation and merge stones. The patient had an abdominal operation to cut off and take out the shunt catheter, as well as a transurethral holmium laser lithotripsy. Bladder perforation and stones are rare examples of complications in V-P surgical procedures. Controlling the effective length of the terminal V-P shunt and modifying it appropriately can effectively reduce these complications.

  6. Shunt attachment and method for interfacing current collection systems

    DOEpatents

    Denney, P.E.; Iyer, N.C.; Hannan, W.F. III.

    1992-12-08

    A composite brush to shunt attachment wherein a volatile component of a composite but mostly metallic brush, used for current collection purposes, does not upon welding or brazing, adversely affect the formation of the interfacial bond with a conductive shunt which carries the current from the zone of the brush. The brush to shunt attachment for a brush material of copper-graphite composite and a shunt of copper, or substituting silver for copper as an alternative, is made through a hot isostatic pressing (HIP). The HIP process includes applying high pressure and temperature simultaneously at the brush to shunt interface, after it has been isolated or canned in a metal casing in which the air adjacent to the interface has been evacuated and the interfacial area has been sealed before the application of pressure and temperature. 6 figs.

  7. Shunt attachment and method for interfacing current collection systems

    DOEpatents

    Denney, Paul E.; Iyer, Natraj C.; Hannan, III, William F.

    1992-01-01

    A composite brush to shunt attachment wherein a volatile component of a composite but mostly metallic brush, used for current collection purposes, does not upon welding or brazing, adversely affect the formation of the interfacial bond with a conductive shunt which carries the current from the zone of the brush. The brush to shunt attachment for a brush material of copper-graphite composite and a shunt of copper, or substituting silver for copper as an alternative, is made through a hot isostatic pressing (HIP). The HIP process includes applying high pressure and temperature simultaneously at the brush to shunt interface, after it has been isolated or canned in a metal casing in which the air adjacent to the interface has been evacuated and the interfacial area has been sealed before the application of pressure and temperature.

  8. Post ventriculoperitoneal shunt abdominal pseudocyst: Challenges posed in management

    PubMed Central

    Hamid, Raashid; Baba, Aejaz A.; Bhat, Nisar A.; Mufti, Gowhar; Mir, Younis A.; Sajad, Wani

    2017-01-01

    Background: In patients with hydrocephalus, the abdominal cavity has been used for absorption of cerebrospinal fluid (CSF) since 1905. Ventriculoperitoneal (VP) shunt operation is followed by abdominal complications in about 5-47% cases. Abdominal CSF pseudo cyst is an uncommon, but well described complication. Aim: This survey was conducted to study the clinical profile and management of this entity. We present our experience with cases of CSF pseudo cyst in children. Materials and Methods: Retrospective analysis of 4 cases diagnosed to have abdominal pseudo cyst following VP shunt between 2008 and 2013. All the four cases were suspected clinically and diagnosis was confirmed by abdominal ultrasonography. Results: In three patients, the cyst was multilocular and of varying size. Fourth one had a unilocular cyst at the lower end of VP shunt. All the four patients had features of varying degree raised intracranial pressure and a two patients had abdominal signs also. All the patients needed open exploration. Cyst fluid was drained and partial to complete excision of the cyst was done along with the repositioning of the shunt in abdominal cavity in three patients and exteriorization of shunt in one patient. Patients were followed for any further complication over a period of 1-year. Conclusion: Abdominal pseudo cyst is a rare complication after VP Shunt and could result in shunt malfunction or abdominal symptoms and signs. Whenever suspected it should be confirmed by imaging, followed by open exploration and repositioning of the shunt. PMID:28413525

  9. Dandy-Walker Malformation: A Clinical and Surgical Outcome Analysis.

    PubMed

    Bokhari, Iram; Rehman, Lal; Hassan, Sher; Hashim, M Sattar

    2015-06-01

    To determine the clinical presentations, complications and mortality in patients with Dandy-Walker Malformation (DWM) after surgery i.e., shunt with y-connector. Case series. Neurosurgery Ward, JPMC, Karachi, from January 2009 to December 2013. Cases of DWM, with associated hydrocephalus, further confirmed on CT scan of brain, were admitted through OPD. Those who were previously operated, those with other associated co-morbid or anomalies were excluded from this study. Combined drainage of the ventricular system and posterior fossa cyst, via dual shunt i.e. cystoperitoneal and ventriculoperitoneal shunt with y-connector was performed in all patients. Complications and mortality after surgical intervention in these patients were noted upto one month after surgery. The data analysis for descriptive statistics was done on SPSS version 20. In this study of 70 patients, majority of the patients were female aged between 1 - 2 years. Hydrocephalus was the predominant symptom as being present in all patients, followed by cerebellar signs in 60 (86%), and other in 5 (7.14%) patients. Complications of surgery were infection and shunt fracture dislocation in 7 (10%) each, malpositioning and shunt blockage in 6 (8.5%) each within one month of surgery, intracranial haemorrhage in 5 (7.14%) patients. Only one patient (1.42%) expired after surgical intervention. In DWM, the commonest presentation is that of hydrocephalus. Shunt malfunction and infection are the commonest complication after shunting. Dual shunt with y-connector has the lowest mortality when compared with other methods for treatment of shunt with y-connector.

  10. Intrahepatic portosystemic venous shunt: diagnosis by color Doppler imaging.

    PubMed

    Kudo, M; Tomita, S; Tochio, H; Minowa, K; Todo, A

    1993-05-01

    Intrahepatic portosystemic venous shunt is a rare clinical entity; only 33 such cases have been reported. It may be congenital, or secondary to portal hypertension. Five patients with this disorder are presented, each of whom was diagnosed by color Doppler imaging, including waveform spectral analysis. One patient with clinical evidence of cirrhosis and portal hypertension had episodes of hepatic encephalopathy and elevated blood levels of ammonia. This patient had a large tubular shunt between the posterior branch of the portal vein and the inferior vena cava. Shunts of this type are considered to be collateral pathways which develop in the hepatic parenchyma as a result of portal hypertension. The other four patients had no evidence of liver disease, and all four evidenced an aneurysmal portohepatic venous shunt within the liver parenchyma. Shunts of this type are considered congenital. The diagnosis of intrahepatic portosystemic venous shunts was established by color Doppler imaging, which demonstrated a direct communication of color flow signals between the portal vein and hepatic vein, in addition to the characterization of the Doppler spectrum at each sampling point from a continuous waveform signal (portal vein) to a turbulent signal (aneurysmal cavity), and finally, to a biphasic waveform signal (hepatic vein). As demonstrated by the five patients, color Doppler imaging is useful in the diagnosis of an intrahepatic portosystemic hepatic venous shunt, and the measurement of shunt ratio may be useful in the follow-up and determining the therapeutic option.

  11. A Comparative Result of Ventriculoperitoneal Shunt, Focusing Mainly on Gravity-Assisted Valve and Programmable Valve

    PubMed Central

    Lee, Won-Chul; Choe, Il-Seung; Park, Sung-Choon; Ha, Young-Soo; Lee, Kyu Chang

    2010-01-01

    Objective Despite rapid evolution of shunt devices, the complication rates remain high. The most common causes are turning from obstruction, infection, and overdrainage into mainly underdrainage. We investigated the incidence of complications in a consecutive series of hydrocephalic patients. Methods From January 2002 to December 2009, 111 patients underwent ventriculoperitoneal (VP) shunting at our hospital. We documented shunt failures and complications according to valve type, primary disease, and number of revisions. Results Overall shunt survival time was 268 weeks. Mean survival time of gravity-assisted valve (GAV) was 222 weeks versus 286 weeks for other shunts. Survival time of programmable valves (264 weeks) was longer than that of pressure-controlled valves (186 weeks). The most common cause for shunt revision was underdrainage (13 valves). The revision rate due to underdrainage in patients with GAV (7 of 10 patients) was higher than that for other valve types. Of 7 patients requiring revision for GAV underdrainage, 6 patients were bedridden. The overall infection rate was 3.6%, which was lower than reported series. Seven patients demonstrating overdrainage had cranial defects when operations were performed (41%), and overdrainage was improved in 5 patients after cranioplasty. Conclusion Although none of the differences was statistically significant, some of the observations were especially notable. If a candidate for VP shunting is bedridden, GAV may not be indicated because it could lead to underdrainage. Careful procedure and perioperative management can reduce infection rate. Cranioplasty performed prior to VP shunting may be beneficial. PMID:21082054

  12. Shunt Devices for the Treatment of Adult Hydrocephalus: Recent Progress and Characteristics

    PubMed Central

    MIYAKE, Hiroji

    2016-01-01

    Various types of shunt valves have been developed during the past 50 years, most of which can be classified into the following categories: (1) fixed differential pressure valves; (2) fixed differential pressure (DP) valves with an antisiphon mechanism; (3) programmable DP valves; (4) programmable DP valves with an antisiphon mechanism; and (5) programmable antisiphon valves. When considering the myriad of possible postoperative condition changes, such as the onset of accidental non-related diseases or trauma in adults, and changes in normal physiological development or anticipation of future shunt removal in children, it has become standard to use the programmable valve as a first choice for cerebrospinal fluid shunting. However, it is still unclear what type of shunt valve is suitable for each individual case. Based on the results of SINPHONI and more recently SINPHONI 2 trials, the programmable DP valve is recommended as the first line shunt valve. The programmable DP valve with an antisiphon mechanism is thought to be beneficial for tall, slender patients, who have a tendency for easily developing complications of overdrainage, however, this type of valve must be used cautiously in obese patients because of the increased risk of underdrainage. Although the current evidence is still insufficient, the programmable antisiphon valve, which costs the same as the programmable DP valve, is also thought to be the first line shunt valve. The quick reference table is applicable for most shunt valves, and for patients with either the ventriculoperitoneal or the lumboperitoneal shunt. PMID:27041631

  13. Shunt Devices for the Treatment of Adult Hydrocephalus: Recent Progress and Characteristics.

    PubMed

    Miyake, Hiroji

    2016-05-15

    Various types of shunt valves have been developed during the past 50 years, most of which can be classified into the following categories: (1) fixed differential pressure valves; (2) fixed differential pressure (DP) valves with an antisiphon mechanism; (3) programmable DP valves; (4) programmable DP valves with an antisiphon mechanism; and (5) programmable antisiphon valves. When considering the myriad of possible postoperative condition changes, such as the onset of accidental non-related diseases or trauma in adults, and changes in normal physiological development or anticipation of future shunt removal in children, it has become standard to use the programmable valve as a first choice for cerebrospinal fluid shunting. However, it is still unclear what type of shunt valve is suitable for each individual case. Based on the results of SINPHONI and more recently SINPHONI 2 trials, the programmable DP valve is recommended as the first line shunt valve. The programmable DP valve with an antisiphon mechanism is thought to be beneficial for tall, slender patients, who have a tendency for easily developing complications of overdrainage, however, this type of valve must be used cautiously in obese patients because of the increased risk of underdrainage. Although the current evidence is still insufficient, the programmable antisiphon valve, which costs the same as the programmable DP valve, is also thought to be the first line shunt valve. The quick reference table is applicable for most shunt valves, and for patients with either the ventriculoperitoneal or the lumboperitoneal shunt.

  14. Outcome of intrahepatic portosystemic shunt diagnosed prenatally.

    PubMed

    Francois, Bérengère; Gottrand, Fréderic; Lachaux, Alain; Boyer, Corinne; Benoit, Bernard; De Smet, Stéphanie

    2017-12-01

    We analyzed the characteristics of the population with congenital portosystemic shunt diagnosed during the antenatal period and the organization of their perinatal care. This multicentric retrospective study included all the patients with a prenatal diagnosis of congenital portosystemic shunt. Between 1999 and 2015, 12 patients were included. Prenatal diagnosis was done at a median 26.5 weeks of gestation (21-34). All the patients presented intrahepatic CPSS, three of them had associated congenital cardiopathy, and one a Bannayan-Zonana syndrome. Ten patients had simple outcome on conservative treatment, eight of them having a spontaneous closure of their portosystemic shunt within the first 2 years of life. One patient had surgical treatment which failed and he developed a focal nodular hyperplasia. Another patient had radiological interventional closure of his shunt which was complicated by a venal portal thrombosis. Outcome of intrahepatic portosystemic shunt diagnosed prenatally is good in the majority of cases. What is known: • Multiples studies exist on congenital porto systemic shunt but when the diagnosis is done after birth. • The evolution, management, and complication are well known. What is new: • There is very few studies with only patients diagnosed in antenatal and it is a large series of cases. • Outcome of intrahepatic portosystemic shunt diagnosed prenatally is good in the majority of cases.

  15. Portal vascular anomalies in Down syndrome: spectrum of clinical presentation and management approach.

    PubMed

    Golewale, Nazar; Paltiel, Harriet J; Fishman, Steven J; Alomari, Ahmad I

    2010-08-01

    The occurrence of portal vascular anomalies in Down syndrome has been sporadically reported in the literature. These rare disorders have a wide spectrum of anatomical and clinical presentations. The aim of this communication was to describe the clinical course, imaging features, and management approaches in patients with this association. We conducted a comprehensive search of the databases of the Vascular Anomalies Center and the Department of Radiology at Children's Hospital Boston for patients with Down syndrome and portal vascular anomalies. Medical records and imaging studies of varying modalities were reviewed. Three children with Down syndrome and portal anomalies (portosystemic shunt, simple arterioportal shunt, complex arterioportal shunt) were managed at our institution. The portosystemic shunt was clinically insignificant and resolved without any intervention. The simple arterioportal shunt was successfully treated with embolization. The complex arterioportal shunt was associated with major congenital cardiac defects and the child ultimately expired despite a decrease in the arterioportal shunting after embolization. Three is a wide spectrum of clinical and anatomical features of portal vascular shunts in Down syndrome. The management approach should be tailored based on the severity of symptoms. Percutaneous embolization can offer a safe, effective, and minimally invasive alternative to the surgical approach in selective cases. Copyright 2010 Elsevier Inc. All rights reserved.

  16. An in vitro lung model to assess true shunt fraction by multiple inert gas elimination.

    PubMed

    Varadarajan, Balamurugan; Vogt, Andreas; Hartwich, Volker; Vasireddy, Rakesh; Consiglio, Jolanda; Hugi-Mayr, Beate; Eberle, Balthasar

    2017-01-01

    The Multiple Inert Gas Elimination Technique, based on Micropore Membrane Inlet Mass Spectrometry, (MMIMS-MIGET) has been designed as a rapid and direct method to assess the full range of ventilation-to-perfusion (V/Q) ratios. MMIMS-MIGET distributions have not been assessed in an experimental setup with predefined V/Q-distributions. We aimed (I) to construct a novel in vitro lung model (IVLM) for the simulation of predefined V/Q distributions with five gas exchange compartments and (II) to correlate shunt fractions derived from MMIMS-MIGET with preset reference shunt values of the IVLM. Five hollow-fiber membrane oxygenators switched in parallel within a closed extracorporeal oxygenation circuit were ventilated with sweep gas (V) and perfused with human red cell suspension or saline (Q). Inert gas solution was infused into the perfusion circuit of the gas exchange assembly. Sweep gas flow (V) was kept constant and reference shunt fractions (IVLM-S) were established by bypassing one or more oxygenators with perfusate flow (Q). The derived shunt fractions (MM-S) were determined using MIGET by MMIMS from the retention data. Shunt derived by MMIMS-MIGET correlated well with preset reference shunt fractions. The in vitro lung model is a convenient system for the setup of predefined true shunt fractions in validation of MMIMS-MIGET.

  17. Patent Foramen Ovale: Association between the Degree of Shunt by Contrast Transesophageal Echocardiography and the Risk of Future Ischemic Neurologic Events

    NASA Technical Reports Server (NTRS)

    Stone, David A.; Godard, Joel; Godard, Joel; Corretti, mary C.; Kittner, Steven J.; Sample, Cindy; Price, Thomas R.; Plotnick, Gary D.

    1996-01-01

    This study investigated whether there is an association between the degree of interatrial shunting across a patent foramen ovale, as determined by saline contrast transesophageal echocardiography, and the risk of subsequent systemic embolic events, including stroke. Thirty-four patients found to have patent foramen ovale during transesophageal echocardiography were divided into two groups on the basis of the maximum number of microbubbles in the left heart in any single frame after intravenous saline contrast injection: group 1 (n = 16) with a "large" degree of shunt (220 microbubbles) and group 2 (n = 18) with a "small" degree of shunt (23 but <20 microbubbles). Patients were followed up over a mean period of 21 months for subsequent systemic embolic events, including transient ischemic attack and stroke. Five (31%) of the patients with large shunts had subsequent ischemic neurologic events, whereas none of the patients with small shunts had embolic events (p= 0.03). These events occurred in spite of antiplatelet or anticoagulant therapy. We conclude that patients with a large degree of shunt across a patent foramen ovale, as determined by contrast transesophageal echocardiography, are at a significantly higher risk for subsequent adverse neurologic events compared with patients with a small degree of shunt.

  18. Syringo-Subarachnoid-Peritoneal Shunt Using T-Tube for Treatment of Post-Traumatic Syringomyelia

    PubMed Central

    Kim, Seon-Hwan; Youm, Jin-Young; Kwon, Hyon-Jo

    2012-01-01

    Various surgical procedures for the treatment of post-traumatic syringomyelia have been introduced recently, but most surgical strategies have been unreliable. We introduce the concept and technique of a new shunting procedure, syringo-subarachnoid-peritoneal shunt. A 54-year-old patient presented to our hospital with a progressive impairment of motion and position sense on the right side. Sixteen years before this admission, he had been treated by decompressive laminectomy for a burst fracture of L1. On his recent admission, magnetic resonance (MR) imaging studies of the whole spine revealed the presence of a huge syrinx extending from the medulla to the L1 vertebral level. We performed a syringo-subarachnoid-peritoneal shunt, including insertion of a T-tube into the syrinx, subarachnoid space and peritoneal cavity. Clinical manifestations and radiological findings improved after the operation. The syringo-subarachnoid-peritoneal shunt has several advantages. First, fluid can communicate freely between the syrinx, the subarachnoid space, and the peritoneal cavity. Secondly, we can prevent shunt catheter from migrating because dural anchoring of the T-tube is easy. Finally, we can perform shunt revision easily, because only one arm of the T-tube is inserted into the intraspinal syringx cavity. We think that this procedure is the most beneficial method among the various shunting procedures. PMID:22993681

  19. Fetal bladder catheterization in severe obstructive uropathy before the 24th week of pregnancy.

    PubMed

    Szaflik, K; Kozarzewski, M; Adamczewski, D

    1998-01-01

    Fetal obstructive uropathy is simple to diagnose before the 24th week of life. Drainage of the pathologically enlarged fetal bladder avoids development of hydronephrosis and destruction of kidneys and, obviously, prevents development of secondary oligohydramnios and pulmonary hypoplasia. The aim of our study was to evaluate the usefulness of a fetal bladder shunt in cases of obstructive uropathy before the 24th week of gestation. From January 1997 we diagnosed 6 cases of fetal obstructive uropathy before the 24th week of gestation. In all cases oligohydramnios or ahydramnios was also observed. After evaluation of the renal function on the basis of fetal urine samples, we shunted 5 fetuses. After routine preparation of the operative field, a special puncture needle was inserted through the abdominal wall of mother and fetus into the fetal bladder. Through the needle a fetal bladder catheter was inserted between the fetal bladder and the amniotic sac. After shunt placement, fetal urine fills the amniotic sac and the fetal bladder is decompressed. After the procedure, the patients were hospitalized and serial sonographic examinations were performed to evaluate shunt function. Bladder size, presence and size of hydronephrosis, and volume of amniotic fluid were evaluated. The Rocket Medical catheters have an excellent 'shape memory'. All but 1 newborns had a good perinatal outcome. Mean Apgar score was 8 at 1 min, weight at delivery was between 1,700 and 3,100 g. No pulmonary hypoplasia was observed. All deliveries were after the 33rd week of gestation (range 33-38 weeks). The minimum drainage time was 11 weeks, maximum 18 weeks. In 2 cases premature delivery occurred because of premature rupture of the membranes. One newborn died of respiratory distress syndrome. Early bladder drainage (before the 24th week of gestation) enables delivery of newborns with a good perinatal outcome, without pulmonary hypoplasia. This method of therapy limits renal damage and allows time for normal development of the fetal lungs.

  20. Hot-spot heating in central-station arrays

    NASA Technical Reports Server (NTRS)

    Gonzalez, C. C.

    1983-01-01

    Hot spot tests performed on the Sacramento Municipal Utility District (SMUD) verificaton array show that current imbalance occurs, resulting in significant hot spot heating. One cause of current imbalance is differences in the average shunt resistances of parallel cell strings due to cell shunt resistance variations. In depth hot spot tests are performed on the verification array with bypass diodes. The tests had several objectives: (1) a comparison of hot spot temperatures achieved under field conditions with those obtained with the present laboratory hot spot test using similar modules; (2) an assessment of current imbalance versus cross tie frequency; and (3) an assessment of different shadow patterns and shadow densities. Instrumented modules are used to vary the number of cross ties and to measure the test-cell current and back-bias voltage. The widths, lengths, and densities of the shadows are varied to maximize the back bias voltage at maximum power current. An infrared camera is used to indicate the existence of hot spots and estimate temperature increases in conjunction with thermocouples. The results of these hot spot tests indicate a sensitivity of back bias heating to the shadow size (amount of cell coverage) and density.

  1. Inherited liver shunts in dogs elucidate pathways regulating embryonic development and clinical disorders of the portal vein.

    PubMed

    van Steenbeek, Frank G; van den Bossche, Lindsay; Leegwater, Peter A J; Rothuizen, Jan

    2012-02-01

    Congenital disorders of the hepatic portal vasculature are rare in man but occur frequently in certain dog breeds. In dogs, there are two main subtypes: intrahepatic portosystemic shunts, which are considered to stem from defective closure of the embryonic ductus venosus, and extrahepatic shunts, which connect the splanchnic vascular system with the vena cava or vena azygos. Both subtypes result in nearly complete bypass of the liver by the portal blood flow. In both subtypes the development of the smaller branches of the portal vein tree in the liver is impaired and terminal branches delivering portal blood to the liver lobules are often lacking. The clinical signs are due to poor liver growth, development, and function. Patency of the ductus venosus seems to be a digenic trait in Irish wolfhounds, whereas Cairn terriers with extrahepatic portosystemic shunts display a more complex inheritance. The genes involved in these disorders cannot be identified with the sporadic human cases, but in dogs, the genome-wide study of the extrahepatic form is at an advanced stage. The canine disease may lead to the identification of novel genes and pathways cooperating in growth and development of the hepatic portal vein tree. The same pathways likely regulate the development of the vascular system of regenerating livers during liver diseases such as hepatitis and cirrhosis. Therefore, the identification of these molecular pathways may provide a basis for future proregenerative intervention.

  2. Lower rates of symptom recurrence and surgical revision after primary compared with secondary endoscopic third ventriculostomy for obstructive hydrocephalus secondary to aqueductal stenosis in adults.

    PubMed

    Sankey, Eric W; Goodwin, C Rory; Jusué-Torres, Ignacio; Elder, Benjamin D; Hoffberger, Jamie; Lu, Jennifer; Blitz, Ari M; Rigamonti, Daniele

    2016-05-01

    OBJECT Endoscopic third ventriculostomy (ETV) is the treatment of choice for obstructive hydrocephalus; however, the success of ETV in patients who have previously undergone shunt placement remains unclear. The present study analyzed 103 adult patients with aqueductal stenosis who underwent ETV for obstructive hydrocephalus and evaluated the effect of previous shunt placement on post-ETV outcomes. METHODS This study was a retrospective review of 151 consecutive patients who were treated between 2007 and 2013 with ETV for hydrocephalus. One hundred three (68.2%) patients with aqueductal stenosis causing obstructive hydrocephalus were included in the analysis. Postoperative ETV patency and aqueductal and cisternal flow were assessed by high-resolution, gradient-echo MRI. Post-ETV Mini-Mental State Examination, Timed Up and Go, and Tinetti scores were compared with preoperative values. Univariate and multivariate analyses were performed comparing the post-ETV outcomes in patients who underwent a primary (no previous shunt) ETV (n = 64) versus secondary (previous shunt) ETV (n = 39). RESULTS The majority of patients showed significant improvement in symptoms after ETV; however, no significant differences were seen in any of the quantitative tests performed during follow-up. Symptom recurrence occurred in 29 (28.2%) patients after ETV, after a median of 3.0 (interquartile range 0.8-8.0) months post-ETV failure. Twenty-seven (26.2%) patients required surgical revision after their initial ETV. Patients who received a secondary ETV had higher rates of symptom recurrence (p = 0.003) and surgical revision (p = 0.003), particularly in regard to additional shunt placement/revision post-ETV (p = 0.005). These differences remained significant after multivariate analysis for both symptom recurrence (p = 0.030) and surgical revision (p = 0.043). CONCLUSIONS Patients with obstructive hydrocephalus due to aqueductal stenosis exhibit symptomatic improvement after ETV, with a relatively low failure rate. Patients with a primary history of shunt placement who undergo ETV as a secondary intervention are at increased risk of symptom recurrence and need for surgical revision post-ETV.

  3. Calibration of piezoelectric RL shunts with explicit residual mode correction

    NASA Astrophysics Data System (ADS)

    Høgsberg, Jan; Krenk, Steen

    2017-01-01

    Piezoelectric RL (resistive-inductive) shunts are passive resonant devices used for damping of dominant vibration modes of a flexible structure and their efficiency relies on the precise calibration of the shunt components. In the present paper improved calibration accuracy is attained by an extension of the local piezoelectric transducer displacement by two additional terms, representing the flexibility and inertia contributions from the residual vibration modes not directly addressed by the shunt damping. This results in an augmented dynamic model for the targeted resonant vibration mode, in which the residual contributions, represented by two correction factors, modify both the apparent transducer capacitance and the shunt circuit impedance. Explicit expressions for the correction of the shunt circuit inductance and resistance are presented in a form that is generally applicable to calibration formulae derived on the basis of an assumed single-mode structure, where modal interaction has been neglected. A design procedure is devised and subsequently verified by a numerical example, which demonstrates that effective mitigation can be obtained for an arbitrary vibration mode when the residual mode correction is included in the calibration of the RL shunt.

  4. LED lamp power management system and method

    DOEpatents

    Gaines, James; Clauberg, Bernd; Van Erp, Josephus A. M.

    2013-03-19

    An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.

  5. Sound absorption of a finite micro-perforated panel backed by a shunted loudspeaker.

    PubMed

    Tao, Jiancheng; Jing, Ruixiang; Qiu, Xiaojun

    2014-01-01

    Deep back cavities are usually required for micro-perforated panel (MPP) constructions to achieve good low frequency absorption. To overcome the problem, a close-box loudspeaker with a shunted circuit is proposed to substitute the back wall of the cavity of the MPP constructions to constitute a composite absorber. Based on the equivalent circuit model, the acoustic impedance of the shunted loudspeaker is formulated first, then a prediction model of the sound absorption of the MPP backed by shunted loudspeaker is developed by employing the mode solution of a finite size MPP coupled by an air cavity with an impendence back wall. The MPP absorbs mid to high frequency sound, and with properly adjusted electrical parameters of its shunted circuit, the shunted loudspeaker absorbs low frequency sound, so the composite absorber provides a compact solution to broadband sound control. Numerical simulations and experiments are carried out to validate the model.

  6. Transient right-to-left shunt in massive pulmonary embolism.

    PubMed

    Panoutsopoulos, G; Ilias, L; Christakopoulou, I

    2000-06-01

    A 56-yr-old man, two months after an operation for an acoustic neurinoma, gradually developed dyspnea. Massive pulmonary embolism (MPE), with a significant right-to-left (R-L) shunt, was seen in a perfusion scan of the lungs with Tc-99m MAA. Radioactivity was noted in the thyroid, spleen, kidneys and brain. A cardiac ultrasound study did not reveal intracardiac shunting. A few days later, when the patient's condition improved, another perfusion scan of the lungs did not show the shunt, whereas a subsequent digital subtraction angiographic study confirmed the diagnosis of MPE but failed to reveal the cause of the shunt. In the absence of any possible pathophysiological mechanism, to explain the observed R-L shunt, we deduce that the particles of Tc-99m MAA might have passed through the precapillary pulmonary arteriovenous anastomoses and/or through dilated pulmonary capillaries, as a result of highly increased pulmonary vascular pressure due to MPE.

  7. Shunting inhibition improves robustness of gamma oscillations in hippocampal interneuron networks by homogenizing firing rates.

    PubMed

    Vida, Imre; Bartos, Marlene; Jonas, Peter

    2006-01-05

    Networks of GABAergic neurons are key elements in the generation of gamma oscillations in the brain. Computational studies suggested that the emergence of coherent oscillations requires hyperpolarizing inhibition. Here, we show that GABA(A) receptor-mediated inhibition in mature interneurons of the hippocampal dentate gyrus is shunting rather than hyperpolarizing. Unexpectedly, when shunting inhibition is incorporated into a structured interneuron network model with fast and strong synapses, coherent oscillations emerge. In comparison to hyperpolarizing inhibition, networks with shunting inhibition show several advantages. First, oscillations are generated with smaller tonic excitatory drive. Second, network frequencies are tuned to the gamma band. Finally, robustness against heterogeneity in the excitatory drive is markedly improved. In single interneurons, shunting inhibition shortens the interspike interval for low levels of drive but prolongs it for high levels, leading to homogenization of neuronal firing rates. Thus, shunting inhibition may confer increased robustness to gamma oscillations in the brain.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harvey, Steven P.; Aguiar, Jeffery A.; Hacke, Peter

    Here, we investigated potential-induced degradation (PID) in silicon mini-modules that were subjected to accelerated stressing to induce PID conditions. Shunted areas on the cells were identified with photoluminescence and dark lock-in thermography (DLIT) imaging. The identical shunted areas were then analyzed via time-of-flight secondary-ion mass spectrometry (TOFSIMS) imaging, 3-D tomography, and high-resolution transmission electron microscopy. The TOF-SIMS imaging indicates a high concentration of sodium in the shunted areas, and 3-D tomography reveals that the sodium extends more than 2 um from the surface below shunted regions. Transmission electron microscopy investigation reveals that a stacking fault is present at an areamore » identified as shunted by DLIT imaging. After the removal of surface sodium, tomography reveals persistent sodium present around the junction depth of 300 nm and a drastic difference in sodium content at the junction when comparing shunted and nonshunted regions.« less

  9. Ovarian hyperstimulation syndrome leading to ventriculoperitoneal shunt malfunction: Case report.

    PubMed

    Azriel, Amit; Fleming, Benjamin; Dior, Uri P; Moscovici, Samuel; Sufaro, Yuval; Awad, Mohammed; Drummond, Kate

    2018-06-01

    Ventriculoperitoneal shunt (VPS) insertion is a common neurosurgical procedure for hydrocephalus. Unfortunately, VPS malfunction is not uncommon, with an estimated cumulative rate of 32% at 5 years. As flow through the shunt is influenced by the pressure gradient between the ventricles and the peritoneal cavity, malfunction may be caused by elevated intra-abdominal pressure. We present a rare patient with ascites following ovarian hyperstimulation syndrome (OHSS) leading to shunt malfunction. OHSS is a potentially life-threatening complication of controlled ovarian stimulation caused by the administration of exogenous gonadotropins. In this patient clinical and radiological resolution of shunt dysfunction were achieved following peritoneocentesis. To our knowledge this is the first described case of OHSS leading to shunt malfunction, emphasizing the importance of awareness, early recognition and proper management of abdominal etiologies of VPS malfunction. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Intramedullary placement of ventricular shunts: a review of using bone as a distal cerebrospinal absorption site in treating hydrocephalus.

    PubMed

    Kassem, Mohammad W; Chern, Joshua; Loukas, Marios; Tubbs, R Shane

    2017-12-01

    Intraosseous (IO) vascular access has been used since the Second World War and is warranted when there is an emergency and/or urgent need to replenish the vascular pool. Despite long-term and satisfactory results from delivering large quantities of intravenous fluid via the medullary space of bone, use of this space for a distant receptacle for cerebrospinal fluid (CSF) diversion has seldom been considered. The current paper reviews the literature regarding the bony medullary space as a receptacle for intravenous fluid and CSF. Previous authors have demonstrated the potential of the diploic space of the calvaria for CSF shunting. Pugh and colleagues tested the ability of the cranium to receive and absorb a small amount of tracer fluid. The literature suggests that intraosseous placement of ventricular diversionary shunts is an alternative to more traditional sites such as the pleural cavity and peritoneum. When these latter locations are not available or are contraindicated, placement in the medullary space of bone is another option available to the surgeon.

  11. Deletion of Rbpj from postnatal endothelium leads to abnormal arteriovenous shunting in mice

    PubMed Central

    Nielsen, Corinne M.; Cuervo, Henar; Ding, Vivianne W.; Kong, Yupeng; Huang, Eric J.; Wang, Rong A.

    2014-01-01

    Arteriovenous malformations (AVMs) are tortuous vessels characterized by arteriovenous (AV) shunts, which displace capillaries and shunt blood directly from artery to vein. Notch signaling regulates embryonic AV specification by promoting arterial, as opposed to venous, endothelial cell (EC) fate. To understand the essential role of endothelial Notch signaling in postnatal AV organization, we used inducible Cre-loxP recombination to delete Rbpj, a mediator of canonical Notch signaling, from postnatal ECs in mice. Deletion of endothelial Rbpj from birth resulted in features of AVMs by P14, including abnormal AV shunting and tortuous vessels in the brain, intestine and heart. We further analyzed brain AVMs, as they pose particular health risks. Consistent with AVM pathology, we found cerebral hemorrhage, hypoxia and necrosis, and neurological deficits. AV shunts originated from capillaries (and possibly venules), with the earliest detectable morphological abnormalities in AV connections by P8. Prior to AV shunt formation, alterations in EC gene expression were detected, including decreased Efnb2 and increased Pai1, which encodes a downstream effector of TGFβ signaling. After AV shunts had formed, whole-mount immunostaining showed decreased Efnb2 and increased Ephb4 expression within AV shunts, suggesting that ECs were reprogrammed from arterial to venous identity. Deletion of Rbpj from adult ECs led to tortuosities in gastrointestinal, uterine and skin vascular beds, but had mild effects in the brain. Our results demonstrate a temporal requirement for Rbpj in postnatal ECs to maintain proper artery, capillary and vein organization and to prevent abnormal AV shunting and AVM pathogenesis. PMID:25209249

  12. Transdiaphragmatic Approach to Attenuate Porto-Azygos Shunts Inserting in the Thorax.

    PubMed

    Or, Matan; Kitshoff, Adriaan; Devriendt, Nausikaa; De Ridder, Marianne; Quist-Rybachuk, Galena; de Rooster, Hilde

    2016-11-01

    To describe the surgical technique and document the application of a transdiaphragmatic approach to attenuate porto-azygos shunts inserting in the thoracic section of the azygos vein. Cadaveric study and prospective case series. Canine cadavers (n=6) and client-owned dogs with porto-azygos shunts inserting in the thoracic section of the azygos vein (n=9). In the cadavers, the azygos vein was filled with aqueous latex. Landmarks were established for creating a safe transdiaphragmatic approach to the caudal intrathoracic portion of the azygos vein. In the clinical cases, porto-azygos communication was diagnosed by trans-splenic portal scintigraphy. All shunts were attenuated close to their insertion site via ventral midline celiotomy and a transdiaphragmatic approach to the shunt. Perioperative complications were recorded. A 3-5 cm incision, 0.5-1 cm ventral and lateral to the level of the aortic hiatus, was made in the pars lumbalis part of the diaphragm. Stay sutures at both sides of the diaphragmatic incision were placed to open up the incision and a retractor was used to push the esophagus away from the aorta. Intrathoracic insertion of the shunt was confirmed intraoperative. Exposure of the shunt insertion site at the azygos vein was excellent in all clinical cases. No intraoperative or postoperative complications were encountered. If thoracic attenuation of a porto-azygos shunt is considered, a transdiaphragmatic approach exposes the insertion site for shunt attenuation. This approach is straightforward, without unnecessary abdominal organ manipulation, and since attenuates at the insertion, avoids missing additional contributing branches. © Copyright 2016 by The American College of Veterinary Surgeons.

  13. Management of Hydrocephalus with Ventriculoperitoneal Shunts: Review of 109 Cases of Children.

    PubMed

    Dakurah, Thomas K; Adams, Fuseini; Iddrissu, Mutawakilu; Wepeba, George Kojo; Akoto, Harry; Bankah, Patrick; Ametefe, Mawuli; Kasu, Philip W

    2016-12-01

    Treatment of hydrocephalus by shunting procedure is associated with variable outcomes, depending on the setting. Results from some published series in sub-Saharan Africa are not so good and various reasons have been given. This study presents preliminary findings of 109 cases of shunted hydrocephalus in children in a 3-year period. The main aim of the study was to evaluate the complications of the procedure in a tertiary-care center. It also seeks to identify ways of reducing such complications where appropriate in subsequent shunt placement procedures. A single-institutional retrospective study was conducted by reviewing 124 patients who had ventriculoperitoneal shunting including revisions, and subgroup analysis was performed in 109 patients younger than 18 years classified as children who had first-time shunt placement between January 2011 and December 2013. Data analysis was performed using Microsoft Excel and SPSS (version 20.0). The mean age at shunt insertion of the subgroup was 5.35 years ± 1.264 standard deviations. Shunt-related complications were identified in 37 of the patients (33.9%). Infections were the most common form of complication, occurring in 16 patients (14.6%). The overall mortality of the 109 patients was 4.59%. The most common indications for shunt insertions were tumoral and congenital lesions, which may offer us benefit with the use of endoscopic third ventriculostomy. Comprehensive follow-up of these patients may give a better picture of the magnitude of the problem; hence the need for properly designed prospective studies to improve the current outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. What are the implications of the spontaneous spleno-renal shunts in liver cirrhosis?

    PubMed Central

    2009-01-01

    Background Although significant advances are expected to be made in the assessment of the portal hypertension-related complications, the prognostic role of spleno-renal shunts has not been fully explored so far. Clarifying this aspect could help tackle the life-treating events occurring in patients suffering from liver cirrhosis. The aim of the study was to analyze the relationships between the spleno-renal shunts presence at doppler ultrasound and the liver cirrhosis complications. Methods Design: eighty one patients out of 129 formed the study population (35 females). Chronic liver damage in these patients was caused by HCV (66), HBV (2), alcohol abuse (2) or unknown etiology, likely non-alcoholic steatohepatitis (11). Setting: two Liver Units of university/primary hospitals in Southern Italy. Main outcome measures: grading of esofageal varices; detection of ascites: assessment of hepatic encephalopathy; evaluation of liver cirrhosis severity; tracking hepatocellular carcinoma; doppler features of spleno-renal shunts and splenic flow velocity; spleen longitudinal diameter at sonography. Results The prevalence of spleno-renal shunts was 18.5%, without no difference concerning the etiology (HCV versus non-HCV, p = 0.870); the prevalence of hepatocellular carcinoma in patients with spleno-renal shunts was superior to that of patients without them (Pearson Chi-square, p = 0.006, power of sample size 74%), also after adjustment for liver decompensation (p = 0.024). The median score of hepatic encephalopathy in patients with and without spleno-renal shunts was similar, i.e., 0 (range, 0-2) versus 0 (0 - 3), p = 0.67. The median splenic vein flow velocity in patients with spleno-renal shunts was significantly inferior to that of patients without them, i.e., 13 cm/sec (95% confidence intervals, 6-18) versus 21 cm/sec (17-24), p < 0.0001. By far the largest percentage of large esophageal varices was in patients without spleno-renal shunts (p = 0.005). In contrast, the frequency of ascites and hepatic encephalopathy severity was overlapping in the two groups. BMI values but not Child-Pugh's classification predicted spleno-renal shunts (Ors = 1.84, 95% confidence intervals = 1.28-2.64, p = 0.001 and 1.145, 95% confidence intervals = 0.77-1.51, p = 0.66). Conclusion Taking into consideration the relatively small sample size, patients with spleno-renal shunts are burdened by an increased incidence of hepatocellular carcinoma. BMI predicted the spleno-renal shunts presence. PMID:19930687

  15. Enzymatic liver function capacity correlates with disease severity of patients with liver cirrhosis: a study with the LiMAx test.

    PubMed

    Malinowski, Maciej; Jara, Maximilian; Lüttgert, Katja; Orr, James; Lock, Johan Friso; Schott, Eckart; Stockmann, Martin

    2014-12-01

    Assessment and quantification of actual liver function is crucial in patients with chronic liver disease to monitor disease progression and predict individual prognosis. Mathematical models, such as model for end-stage liver disease, are used for risk stratification of patients with chronic liver disease but do not include parameters that reflect the actual functional state of the liver. We aimed to evaluate the potential of a (13)C-based liver function test as a stratification tool by comparison with other liver function tests and clinical parameters in a large sample of healthy controls and cirrhotic patients. We applied maximum liver function capacity (LiMAx) to evaluate actual liver function in 347 patients with cirrhosis and in 86 controls. LiMAx showed strong negative correlation with Child-Pugh Score (r = -0.707; p < 0.001), MELD (r = -0.686; p < 0.001) and liver function tests. LiMAx was lower in patients with liver cirrhosis compared to healthy controls [99 (57-160) µg/kg/h vs. 412 (365-479) µg/kg/h, p < 0.001] and differed among Child-Pugh classes [a: 181 (144-227) µg/kg/h, b: 96 (62-132) µg/kg/h and c: 52 (37-81) µg/kg/h; p < 0.001]. When stratified patients according to disease severity, LiMAx results were not different between cirrhotic patients and cirrhotic patients with transjugular intrahepatic portosystemic shunt. LiMAx appears to provide reliable information on remnant enzymatic liver function in chronic liver disease and allows graduation of disease severity.

  16. Endovascular diagnosis and intervention in patients with isolated hyperammonemia, with or without ascites, after liver transplantation.

    PubMed

    Belenky, Alexander; Igov, Igor; Konstantino, Youval; Bachar, Gil N; Mor, Eitan; Graif, Franklyn; Ben-Ari, Ziv; Tur-Kaspa, Ran; Atar, Eli

    2009-02-01

    Hyperammonemia with or without ascites with normal synthetic liver functions after liver transplantation might indicate the presence of anastomotic stenosis of the portal or hepatic vein or the existence of a patent portosystemic shunt. The authors describe six patients, three children after split-liver transplantation and three adults after cadaver liver transplantation, who presented with hyperammonemia. Three patients had ascites. All lesions were successfully treated percutaneously; stents were placed in patients with anastomotic stenoses and coil embolization was performed in patients with patent portosystemic shunts--with either transhepatic or transjugular approaches according to the site of the abnormality. Ammonia levels returned to normal, and ascites had regressed completely for at least 3 months.

  17. Management Strategies for Hydrocephalus in Alobar Holoprosencephaly: A Case Report and Discussion.

    PubMed

    Sarica, Can; Yucetas, Cem; Ozen, Ali; Ucler, Necati; Konca, Capan; Akar, Selahattin

    2018-06-14

    Holoprosencephaly is a rare congenital malformation resulting from an impaired midline division of the prosencephalon into distinct cerebral hemispheres. Hydrocephalus is a frequent problem among the few survivors with alobar holoprosencephaly (aHPE), its most severe form. The literature about neurosurgical management of hydrocephalus in this condition is limited and dispersed, and there are still some points that need to be resolved. We report the case of a newborn with aHPE, hydrocephalus, and central diabetes insipidus. We delineate the complexity of the management of these patients and emphasize the benefits of using an initial programmable shunt valve. Further discussion about management strategies includes reviewing previous reports and the benefits of shunting for hypothalamic osmoreceptor function. © 2018 S. Karger AG, Basel.

  18. Congenital intrahepatic portosystemic venous shunt presenting with paraparesis as the initial symptom.

    PubMed

    Torigoe, Masataka; Maeshima, Keisuke; Takeshita, Yasushi

    2013-01-01

    An 85-year-old woman was hospitalized with rapidly progressive paraparesis without altered consciousness, although she was not definitively diagnosed. She developed acute drowsiness and disorientation several days later. An intrahepatic portosystemic venous shunt (IPSVS) was observed on enhanced computed tomography, and hyperammonemia suggested leakage of neurotoxins from the shunt as the etiology of the patient's symptoms. Her neurological symptoms and hyperammonemia improved following transcatheter shunt embolization. We diagnosed her with hepatic myelopathy, which is a rare complication of liver cirrhosis and portosystemic venous shunts. Hepatic myelopathy resulting from a congenital IPSVS has not been previously reported. A diagnosis of hepatic myelopathy should be ruled out in diagnostically difficult cases of paraparesis.

  19. Congenital intrahepatic portosystemic venous shunt and liver mass in a child patient: successful endovascular treatment with an amplatzer vascular plug (AVP).

    PubMed

    Lee, Sae Ah; Lee, Young Seok; Lee, Kun Song; Jeon, Gyeong Sik

    2010-01-01

    A congenital intrahepatic portosystemic shunt is a rare anomaly; but, the number of diagnosed cases has increased with advanced imaging tools. Symptomatic portosystemic shunts, especially those that include hyperammonemia, should be treated; and various endovascular treatment methods other than surgery have been reported. Hepatic masses with either an intra- or extrahepatic shunt also have been reported, and the mass is another reason for treatment. Authors report a case of a congenital intrahepatic portosystemic shunt with a hepatic mass that was successfully treated using a percutaneous endovascular approach with vascular plugs. By the time the first short-term follow-up was conducted, the hepatic mass had disappeared.

  20. Simultaneous Umbilical Hernia Repair with Transumbilical Ventriculoperitoneal Shunt Placement.

    PubMed

    Montalbano, Michael J; Loukas, Marios; Oakes, W Jerry; Tubbs, R Shane

    2017-01-01

    Recently, placement of a ventriculoperitoneal shunt via a transumbilical approach has been reported. Herein, we report the repair of an umbilical hernia via the same incision and introduction of the distal end of a ventricultoperitoneal shunt into the peritoneal cavity in 3 patients. A case illustration is included. Both hernia repair and placement of the distal end of the ventriculoperitoneal shunt were uncomplicated in our small case series. To our knowledge, simultaneous repair of an umbilical hernia followed by transumbilical shunt placement has not been reported. As umbilical hernias are so common in infants, this finding, based on our experience, should not exclude placement of peritoneal tubing in the same setting. © 2017 S. Karger AG, Basel.

  1. Metabolic regulation as a consequence of anaerobic 5-methylthioadenosine recycling in Rhodospirillum rubrum

    DOE PAGES

    North, Justin A.; Sriram, Jaya; Chourey, Karuna; ...

    2016-07-12

    Rhodospirillum rubrum possesses a novel oxygen-independent, aerobic methionine salvage pathway (MSP) for recycling methionine from 5-methylthioadenosine (MTA), the MTA-isoprenoid shunt. This organism can also metabolize MTA as a sulfur source under anaerobic conditions, suggesting that the MTA-isoprenoid shunt may also function anaerobically as well. In this study, deep proteomics profiling, directed metabolite analysis, and reverse transcriptase quantitative PCR (RT-qPCR) revealed metabolic changes in response to anaerobic growth on MTA versus sulfate as sole sulfur source. The abundance of protein levels associated with methionine transport, cell motility, and chemotaxis increased in the presence of MTA over that in the presence ofmore » sulfate. Purine salvage from MTA resulted primarily in hypoxanthine accumulation and a decrease in protein levels involved in GMP-to-AMP conversion to balance purine pools. Acyl coenzyme A (acyl-CoA) metabolic protein levels for lipid metabolism were lower in abundance, whereas poly-β-hydroxybutyrate synthesis and storage were increased nearly 10-fold. The known R. rubrum aerobic MSP was also shown to be upregulated, to function anaerobically, and to recycle MTA. This suggested that other organisms with gene homologues for the MTA-isoprenoid shunt may also possess a functioning anaerobic MSP. In support of our previous findings that ribulose-1,5-carboxylase/oxygenase (RubisCO) is required for an apparently purely anaerobic MSP, RubisCO transcript and protein levels both increased in abundance by over 10-fold in cells grown anaerobically on MTA over those in cells grown on sulfate, resulting in increased intracellular RubisCO activity. Lastly, these results reveal for the first time global metabolic responses as a consequence of anaerobic MTA metabolism compared to using sulfate as the sulfur source.« less

  2. Metabolic regulation as a consequence of anaerobic 5-methylthioadenosine recycling in Rhodospirillum rubrum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    North, Justin A.; Sriram, Jaya; Chourey, Karuna

    Rhodospirillum rubrum possesses a novel oxygen-independent, aerobic methionine salvage pathway (MSP) for recycling methionine from 5-methylthioadenosine (MTA), the MTA-isoprenoid shunt. This organism can also metabolize MTA as a sulfur source under anaerobic conditions, suggesting that the MTA-isoprenoid shunt may also function anaerobically as well. In this study, deep proteomics profiling, directed metabolite analysis, and reverse transcriptase quantitative PCR (RT-qPCR) revealed metabolic changes in response to anaerobic growth on MTA versus sulfate as sole sulfur source. The abundance of protein levels associated with methionine transport, cell motility, and chemotaxis increased in the presence of MTA over that in the presence ofmore » sulfate. Purine salvage from MTA resulted primarily in hypoxanthine accumulation and a decrease in protein levels involved in GMP-to-AMP conversion to balance purine pools. Acyl coenzyme A (acyl-CoA) metabolic protein levels for lipid metabolism were lower in abundance, whereas poly-β-hydroxybutyrate synthesis and storage were increased nearly 10-fold. The known R. rubrum aerobic MSP was also shown to be upregulated, to function anaerobically, and to recycle MTA. This suggested that other organisms with gene homologues for the MTA-isoprenoid shunt may also possess a functioning anaerobic MSP. In support of our previous findings that ribulose-1,5-carboxylase/oxygenase (RubisCO) is required for an apparently purely anaerobic MSP, RubisCO transcript and protein levels both increased in abundance by over 10-fold in cells grown anaerobically on MTA over those in cells grown on sulfate, resulting in increased intracellular RubisCO activity. Lastly, these results reveal for the first time global metabolic responses as a consequence of anaerobic MTA metabolism compared to using sulfate as the sulfur source.« less

  3. Metabolic Regulation as a Consequence of Anaerobic 5-Methylthioadenosine Recycling in Rhodospirillum rubrum

    PubMed Central

    North, Justin A.; Sriram, Jaya; Chourey, Karuna; Ecker, Christopher D.; Sharma, Ritin; Wildenthal, John A.; Hettich, Robert L.

    2016-01-01

    ABSTRACT Rhodospirillum rubrum possesses a novel oxygen-independent, aerobic methionine salvage pathway (MSP) for recycling methionine from 5-methylthioadenosine (MTA), the MTA-isoprenoid shunt. This organism can also metabolize MTA as a sulfur source under anaerobic conditions, suggesting that the MTA-isoprenoid shunt may also function anaerobically as well. In this study, deep proteomics profiling, directed metabolite analysis, and reverse transcriptase quantitative PCR (RT-qPCR) revealed metabolic changes in response to anaerobic growth on MTA versus sulfate as sole sulfur source. The abundance of protein levels associated with methionine transport, cell motility, and chemotaxis increased in the presence of MTA over that in the presence of sulfate. Purine salvage from MTA resulted primarily in hypoxanthine accumulation and a decrease in protein levels involved in GMP-to-AMP conversion to balance purine pools. Acyl coenzyme A (acyl-CoA) metabolic protein levels for lipid metabolism were lower in abundance, whereas poly-β-hydroxybutyrate synthesis and storage were increased nearly 10-fold. The known R. rubrum aerobic MSP was also shown to be upregulated, to function anaerobically, and to recycle MTA. This suggested that other organisms with gene homologues for the MTA-isoprenoid shunt may also possess a functioning anaerobic MSP. In support of our previous findings that ribulose-1,5-carboxylase/oxygenase (RubisCO) is required for an apparently purely anaerobic MSP, RubisCO transcript and protein levels both increased in abundance by over 10-fold in cells grown anaerobically on MTA over those in cells grown on sulfate, resulting in increased intracellular RubisCO activity. These results reveal for the first time global metabolic responses as a consequence of anaerobic MTA metabolism compared to using sulfate as the sulfur source. PMID:27406564

  4. Long-term outcomes of adult chronic idiopathic hydrocephalus treated with a ventriculo-peritoneal shunt.

    PubMed

    Illán-Gala, I; Pérez-Lucas, J; Martín-Montes, A; Máñez-Miró, J; Arpa, J; Ruiz-Ares, G

    2017-05-01

    Adult chronic idiopathic hydrocephalus (ACIH) is a cause of dementia that can be treated by implanting a ventriculo-peritoneal shunt (VPS). We aim to study clinical and functional outcomes in patients with ACIH corrected with a VPS. Observational cohort study of patients diagnosed with probable ACIH (Japan Neurosurgical Society guidelines) and undergoing shunt placement between 2008 and 2013 in a centre of reference for neurosurgery in Spain. Clinical improvement was classified in 4 categories (resolution, partial improvement, equivocal improvement, and no improvement); functional outcome was assessed on the modified Rankin scale (mRS). The study included 29 patients with a mean age of 73.9 years; 62.1% were male and 65.5% had hypertension. Clinical improvement (complete or partial) was observed in 58% after one year and in 48% by the end of the follow-up period (mean follow-up time was 37.8 months). Older age, presence of hypertension, and surgery-related complications were more prevalent in the group responding poorly to treatment. One patient died, 20.7% experienced severe complications, and 69% were dependent (mRS ≥ 3) by the end of the follow-up period. Age at diagnosis was independently associated with poorer clinical response at one year and a higher degree of dependency by the end of follow-up. Symptomatic benefits offered by VPS were partial and transient; treatment was associated with a high complication rate and poor functional outcomes in the long term, especially in the oldest patients. Copyright © 2015 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Prediction of Susceptibility to Acute Mountain Sickness Using Hypoxia-Induced Intrapulmonary Arteriovenous Shunt and Intracardiac Shunt Fractions

    DTIC Science & Technology

    2012-10-31

    intrapulmonary and intracardiac shunt using saline contrast echocardiography to determine bubble/shunt scores. We will also use nuclear medicine imaging to...subjects have completed saline contrast echocardiography while breathing hypoxic gas mixtures. For Task #2 “10 hr hypoxic exposure and AMS... echocardiography while breathing an FIO2=0.14, will be susceptible or resistant to developing AMS after 10 hr hypoxic exposure. For Task #3 “Hypoxia

  6. Lower incidence of reoperation with longer shunt survival with adult ventriculoperitoneal shunts placed for hemorrhage-related hydrocephalus.

    PubMed

    Hoh, Brian L; Lang, Shih-Shan; Ortiz, Michael V; Chi, Yueh-Yun; Lewis, Stephen B; Pincus, David W

    2008-07-01

    The incidence of reoperation for ventriculoperitoneal shunts (VPS) in adults, although lower than in pediatric patients, is not insignificant. We hypothesize that adult VPS placed for hemorrhage-related hydrocephalus have a lower incidence of reoperation than those placed for other types of hydrocephalus. We retrospectively reviewed all adult (>/= 20 yr) VPS initially placed from February 2001 to August 2006 at the University of Florida. We determined the incidence and time interval to reoperation. Follow-up was conducted by telephone interview and review of medical records. A total of 286 adult VPS were initially placed: 96 (34%) hemorrhage and 190 (66%) nonhemorrhage. A total of 15 (16%) hemorrhage patients underwent 22 shunt reoperations, compared with 50 (27%) nonhemorrhage patients who underwent 82 shunt reoperations (P = 0.0316). A Poisson regression analysis of the number of reoperations, factoring hemorrhage, age, and sex, demonstrated a significantly lower incidence of reoperation in hemorrhage patients (P = 0.0900). A Cox proportional hazards model analysis of time to first reoperation, factoring hemorrhage, age, and sex, demonstrated a significantly longer shunt survival in hemorrhage patients (P = 0.0404). Adult VPS placed for hemorrhage-related hydrocephalus have a significantly lower incidence of reoperation and significantly longer shunt survival. This result may be related to an incidence of transient shunt dependency in patients with hemorrhage-related hydrocephalus. However, the precise mechanism remains unclear.

  7. Impact of Magnetic Field on Pressures of Programmable Cerebrospinal Fluid Shunts: An Experimental Study.

    PubMed

    Altun, Idiris; Yuksel, Kasim Zafer; Mert, Tufan

    2017-01-01

    To investigate whether programmable cerebrospinal fluid (CSF) shunts are influenced by exposure to the magnetic field and to compare the effects of magnetic field in 4 different brands of programmable CSF shunts. This experimental study was performed in the laboratory using a novel design of magnetic field. Four types of programmable CSF shunts (Miethke®, Medtronic®, Sophysa® and Codman®Hakim®) were exposed to the magnetic field generated by an apparatus consisting of Helmholtz coil for 5 minutes. In every CSF shunt, initial pressures were adjusted to 110 mm H2O and pressures after exposure to magnetic field were noted. These measurements were implemented at frequencies of 5 Hz, 20 Hz, 30 Hz, 40 Hz, 60 Hz and 80 Hz. In each type, three shunts were utilized and evaluations were made twice for every shunt. At 5, 30, 40 and 60 Hz, Groups 1, 2 and 3 had significantly higher average pressures than Group 4. At 20 and 80 Hz, Groups 1 and 2 had notably different pressure values than Groups 3 and 4. Group 3 displayed the highest pressure, while Group 4 demonstrated the lowest pressure. Exposure to magnetic fields may affect the pressures of programmable CSF shunts. However, further controlled, clinical trials are warranted to elucidate the in-vivo effects of magnetic field exposure.

  8. Elective minimally invasive coronary artery bypass: Shunt or tournique occlusion? Assessment of a protective role of perioperative left anterior descending shunting on myocardial damage. A prospective randomized study

    PubMed Central

    2012-01-01

    Background To determine impact of intraluminal-left anterior descending shunt to prevent myocardial damage in minimally invasive coronary artery bypass. Methods 38 patients were randomly assigned to external tournique occlusion (n = 19) or intraluminal-left anterior descending shunt group (n = 19). Blood samples for cardiac troponin T were collected at 30 minutes prior to, 6 and 24 hours after surgery. Results One patient in external tournique occlusion and two patients in intraluminal-left anterior descending shunt group were excluded from futher analysis due to preoperative cardiac troponin T level above the 99th-percentile. Postoperatively, each six patients in external tournique occlusion (33.3%) and intraluminal-left anterior descending shunt (35.3%) group were above the 99th-percentile. Two patients from each group (external tournique occlusion group 11.1% vs. intraluminal-left anterior descending shunt group 11.8%) had peak values above 10-% coeficient of variation cutoff (p = 1). There were no significant differences in between both groups at all studied timepoints. Conclusion There was no protective effect of intraluminal shunting on myocardial damage compared to short-term tournique occlusion. It is upon the surgeon's discretion which method may preferrably be used to achieve a bloodless field in grafting of the non-occluded left anterior descending in minimally invasive coronary artery bypass. PMID:22809563

  9. Use of the proGAV shunt valve in normal-pressure hydrocephalus.

    PubMed

    Toma, Ahmed K; Tarnaris, Andrew; Kitchen, Neil D; Watkins, Laurence D

    2011-06-01

    Overdrainage is a common complication associated with shunt insertion in normal-pressure hydrocephalus (NPH) patients. Using adjustable valves with antigravity devices has been shown to reduce its incidence. The optimal starting setting of an adjustable shunt valve in NPH is debatable. To audit our single-center practice of setting adjustable valves. We performed a retrospective review of clinical records of all NPH patients treated in our unit between 2006 and 2009 by the insertion of shunts with a proGAV valve, recording demographic and clinical data, shunt complications, and revision rates. Radiological reports of postoperative follow-up computed tomography scans of the brain were reviewed for detected subdural hematomas. A proGAV adjustable valve was inserted in 50 probable NPH patients between July 2006 and November 2009. Mean ± SD age was 76 ± 7 years. Mean follow-up was 15 months. The initial shunt setting was 6 ± 3 cm H2O, and the final setting was 4.9 ± 1.9 cm H2O. Nineteen patients required 24 readjustment procedures (readjustment rate, 38%; readjustment number, 0.48 times per patient). One patient (2%) developed delayed bilateral subdural hematoma after readjustment of his shunt valve setting as an outpatient. Starting with a low opening pressure setting on a proGAV adjustable shunt valve does not increase the chances of overdrainage complications and reduces the need for repeated readjustments.

  10. The use of abdominal binders to treat over-shunting headaches.

    PubMed

    Sklar, Frederick H; Nagy, Laszlo; Robertson, Brian D

    2012-06-01

    Headaches are common in children with shunts. Headaches associated with over-shunting are typically intermittent and tend to occur later in the day. Lying down frequently makes the headaches better. This paper examines the efficacy of using abdominal binders to treat over-shunting headaches. Over an 18-year period, the senior author monitored 1027 children with shunts. Office charts of 483 active patients were retrospectively reviewed to identify those children with headaches and, in particular, those children who were thought to have headaches as a result of over-shunting. Abdominal binders were frequently used to treat children with presumed over-shunting headaches, and these data were analyzed. Of the 483 patients undergoing chart review, 258 (53.4%) had headache. A clinical diagnosis of over-shunting was made in 103 patients (21.3% overall; 39.9% of patients with headache). In 14 patients, the headaches were very mild (1-2 on a 5-point scale) and infrequent (1 or 2 per month), and treatment with an abdominal binder was not thought indicated. Eighty-nine patients were treated with a binder, but 19 were excluded from this retrospective study for noncompliance, interruption of the binder trial, or lack of follow-up. The remaining 70 pediatric patients, who were diagnosed with over-shunting headaches and were treated with abdominal binders, were the subjects of a more detailed retrospective study. Significant headache improvement was observed in 85.8% of patients. On average, the patients wore the binders for approximately 1 month, and headache relief usually persisted even after the binders were discontinued. However, the headaches eventually did recur in many of the patients more than a year later. In these patients, reuse of the abdominal binder was successful in relieving headaches in 78.9%. The abdominal binder is an effective, noninvasive therapy to control over-shunting headaches in most children. This treatment should be tried before any surgery is considered. It is suggested that the abdominal binder may modulate abnormally increased intracranial pulse pressures associated with over-shunting. Interactions with the cerebrovascular bed are suspected to account for persistent headache relief after the binder is discontinued.

  11. Prenatal surgery for myelomeningocele and the need for cerebrospinal fluid shunt placement

    PubMed Central

    Tulipan, Noel; Wellons, John C.; Thom, Elizabeth A.; Gupta, Nalin; Sutton, Leslie N.; Burrows, Pamela K.; Farmer, Diana; Walsh, William; Johnson, Mark P.; Rand, Larry; Tolivaisa, Susan; D’Alton, Mary E.; Adzick, N. Scott

    2016-01-01

    Object The Management of Myelomeningocele Study (MOMS) was a multicenter randomized trial comparing the safety and efficacy of prenatal and postnatal closure of myelomeningocele. The trial was stopped early because of the demonstrated efficacy of prenatal surgery, and outcomes on 158 of 183 pregnancies were reported. Here, the authors update the 1-year outcomes for the complete trial, analyze the primary and related outcomes, and evaluate whether specific prerandomization risk factors are associated with prenatal surgery benefit. Methods The primary outcome was a composite of fetal loss or any of the following: infant death, CSF shunt placement, or meeting the prespecified criteria for shunt placement. Primary outcome, actual shunt placement, and shunt revision rates for prenatal versus postnatal repair were compared. The shunt criteria were reassessed to determine which were most concordant with practice, and a new composite outcome was created from the primary outcome by replacing the original criteria for CSF shunt placement with the revised criteria. The authors used logistic regression to estimate whether there were interactions between the type of surgery and known prenatal risk factors (lesion level, gestational age, degree of hindbrain herniation, and ventricle size) for shunt placement, and to determine which factors were associated with shunting among those infants who underwent prenatal surgery. Results Ninety-one women were randomized to prenatal surgery and 92 to postnatal repair. The primary outcome occurred in 73% of infants in the prenatal surgery group and in 98% in the postnatal group (p < 0.0001). Actual rates of shunt placement were only 44% and 84% in the 2 groups, respectively (p < 0.0001). The authors revised the most commonly met criterion to require overt clinical signs of increased intracranial pressure, defined as split sutures, bulging fontanelle, or sunsetting eyes, in addition to increasing head circumference or hydrocephalus. Using these modified criteria, only 3 patients in each group met criteria but did not receive a shunt. For the revised composite outcome, there was a difference between the prenatal and postnatal surgery groups: 49.5% versus 87.0% (p < 0.0001). There was also a significant reduction in the number of children who had a shunt placed and then required a revision by 1 year of age in the prenatal group (15.4% vs 40.2%, relative risk 0.38 [95% CI 0.22–0.66]). In the prenatal surgery group, 20% of those with ventricle size < 10 mm at initial screening, 45.2% with ventricle size of 10 up to 15 mm, and 79.0% with ventricle size ≥ 15 mm received a shunt, whereas in the postnatal group, 79.4%, 86.0%, and 87.5%, respectively, received a shunt (p = 0.02). Lesion level and degree of hindbrain herniation appeared to have no effect on the eventual need for shunting (p = 0.19 and p = 0.13, respectively). Similar results were obtained for the revised outcome. Conclusions Larger ventricles at initial screening are associated with an increased need for shunting among those undergoing fetal surgery for myelomeningocele. During prenatal counseling, care should be exercised in recommending prenatal surgery when the ventricles are 15 mm or larger because prenatal surgery does not appear to improve outcome in this group. The revised criteria may be useful as guidelines for treating hydrocephalus in this group. PMID:26369371

  12. Gravitational shunt units may cause under-drainage in bedridden patients.

    PubMed

    Kaestner, S; Kruschat, T; Nitzsche, N; Deinsberger, W

    2009-03-01

    Implantation of a shunt in a hydrocephalic patient still carries a risk of complications such as over-drainage and under-drainage. Gravitational shunt units are especially designed to minimize the problem of over-drainage. Nevertheless, these valves carry a risk of under-drainage. The best choice of valve for a patient is still challenging. The purpose of this survey was to identify in which patients a gravitational shunt valve is liable to lead to under-drainage. Patients with hydrocephalus entered prospectively into a data base were reviewed retrospectively. The patients were treated between January 2006 to the end of Feb 2007 and those experiencing under- or over-drainage were identified. Thirty-five ventriculo-peritoneal shunt systems were implanted in adult patients. The cause of the hydrocephalus was: normal pressure hydrocephalus in 18 patients, post-haemorrhagic following subarachnoid or intracerebral haemorrhage in 11, associated with a tumour in four and followed a head injury in two patients. Three different valves were used: an adjustable shunt valve with gravitational unit (Pro-GAV 0-20/25 in 21 patients), a gravitational shunt valve with fixed opening pressure (GAV 5/30 in nine patients) and an adjustable differential valve (Hakim medos in five patients). Four patients developed severe, valve-related under-drainage. Each had received a gravitational shunt valve and all were bedridden. In two of these patients it was necessary to change the valve. One patient who had received a differential valve, after regaining mobility developed severe over-drainage with bilateral subdural haematomas. Over-drainage was not seen in long-term bedridden patients with a differential shunt valve. If a bedridden patient with a gravitational shunt valve system lies with a slightly elevated head, this leads to activation of the gravitational unit and this may cause under drainage. As a result, we advise not using an anti-siphon devices in a patient who is bedridden for a long period.

  13. [Hemodynamic study of the patient with hemorrhagic portal hypertension: importance of the left renal vein in patients with a distal splenorenal shunt (Warren)].

    PubMed

    Orozco, Héctor; Tielve, Manuel; Ramos, Guillermo; Mercado, Miguel Angel

    2006-01-01

    There is no information in the literature about surgical outcome of the distal splenorenal shunt (Warren shunt) in those patients with anomalous flow in the left renal vein to the inferior vena cava. The purpose of this manuscript was to evaluate the incidence of thrombosis in the Warren shunt in those patients with anomalous flow in the left renal vein to the inferior vena cava. We performed a prospective, descriptive and longitudinal study in those patients who performed a surgical procedure to the treatment of hemorrhagic portal hypertension in a tertiary referral center in Mexico City during a one year period (2002-2003). Before the surgical procedure an arterial and venous angiographic study was done including celiac axis, superior mesenteric artery and splenic artery. The patients were scheduled in the outpatient office the first, third, sixth month and the year after the surgical procedure. We looked in them for gastrointestinal bleeding secondary to portal hypertension. In those patients with Warren shunt an angiographic study was done during the first month after the surgical procedure. Twenty eight patients were included, 17 of them women (60.7%). Median patient age was 48 years old. In 20 patients a Warren shunt were done and in eigth patients a devascularization operation were done. The anomalous flow of the left renal vein was identified in nine patients (28.7%). In seven of them a Warren shunt were done and in two of them a devascularization operation were done. We didn't find gastrointestinal bleeding or thrombosis of the Warren shunt in any of these patients. In those cases of patients with anomalous flow in the left renal vein a Warren shunt can be performed. In this study we didn't find thrombosis of the shunt or gastrointestinal bleeding. In this way a surgical decompression of the portal system can be done preventing bleeding episodes.

  14. Percutaneous Transjugular Direct Porto-caval Shunt in Patients with Budd-Chiari Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quateen, A.; Pech, M.; Berg, T.

    The purpose of the study was to evaluate the feasibility and effectiveness of direct porto-caval shunts in patients with Budd-Chiari syndrome (BCS) in whom there is no access to the hepatic veins during transjugular intrahepatic portosystemic shunt (TIPSS). We included six consecutive patients with fulminant/acute Budd-Chiari syndrome (mean age: 35 years) in whom a conventional TIPSS was not possible due to inaccessible hepatic veins. We performed a direct porto-caval shunt via a transhepatic approach. Patients were followed up by means of clinical examination, laboratory investigations, and Doppler ultrasound. TIPSS implantation from the inferior vena cava (IVC) was successful in allmore » six patients (100%). The median transhepatic shunt length was 9 cm (8-10 cm). No procedure-related complications were observed in our patients. Early shunt occlusion occurred in three out of six patients (50%). In all three of these patients, the stent used to stabilize the shunt ended 1-2 cm before reaching the IVC. All occlusions were successfully recanalized. One of these patients developed recurrent early shunt as well as mesenteric and splenic vein occlusions. She died 7 days after TIPSS placement due to an unmanageable coagulation disorder. The remaining five patients were followed up by planned clinical examination and laboratory investigations (mean follow-up time was 15 months; patient 1 was followed up for 13 months, patient 2 for 14 months, patient 3 for 15 months, and patients 4 and 5 for 16 months) and all displayed a complete and durable resolution of liver failure and ascites without reintervention. In patients with acute liver failure originating from BCS and inaccessible hepatic veins, a direct transhepatic porto-caval shunt can be performed safely and effectively under ultrasound guidance. Future studies in larger patient groups should investigate if the patency of transcaval TIPSS with long transhepatic shunt segments is similar compared to conventional TIPSS via the hepatic vein.« less

  15. International Space Station Solar Array Wing On-Orbit Electrical Performance Degradation Measured

    NASA Technical Reports Server (NTRS)

    Gustafson, Eric D.; Kerslake, Thomas W.

    2004-01-01

    The port-side photovoltaic power module (P6) was activated on the International Space Station in December 2000. P6 provides electrical power to channels 2B and 4B to operate ISS power loads. A P6 is shown in the preceding photograph. This article highlights the work done at the NASA Glenn Research Center to calculate the on-orbit degradation of the P6 solar array wings (SAWs) using on-orbit data from December 2000 to February 2003. During early ISS operations, the 82 strings of photovoltaic cells that make up a SAW can provide much more power than is necessary to meet the demand. To deal with excess power, a sequential shunt unit successively shunts the current from the strings. This shunt current was the parameter chosen for the SAW performance degradation study for the following reasons: (1) it is based on a direct shunt current measurement in the sequential shunt unit, (2) the shunt current has a low temperature dependence that reduces the data correction error from using a computationally derived array temperature, and (3) the SSU shunt current is essentially the same as the SAW short-circuit current on a per-string basis.

  16. Vaginal Migration of Ventriculoperitoneal Shunt Catheter and Cerebrospinal Fluid Leak as a Complication of Hysterectomy.

    PubMed

    Houten, John K; Smith, Shiela; Schwartz, Amit Y

    2017-08-01

    Ventriculoperitoneal (VP) shunting is a common neurosurgical procedure to treat hydrocephalus that diverts cerebrospinal fluid from the cerebral ventricles to the peritoneal cavity for reabsorption. The distal catheter may potentially migrate through any potential or iatrogenic opening in the peritoneal cavity. Increasingly successfully management of childhood hydrocephalus and adult-onset conditions leading to hydrocephalus, such as subarachnoid hemorrhage, is leading many adult female patients harboring VP shunts needing to undergo hysterectomy. Hysterectomy creates a potential defect though which a VP shunt catheter may migrate. It is not known whether the hysterectomy cuff closure technique may affect the likelihood of distal catheter migration though the repair site. We report the case of a 38-year-old woman with a VP shunt who underwent laparoscopic hysterectomy via an open vaginal cuff technique who subsequently presented with vaginal cerebrospinal fluid leakage secondary to migration of the distal shunt catheter through the hysterectomy cuff. Vaginal migration of the distal VP shunt catheter is a possible complication of hysterectomy. The authors postulate that an open cuff hysterectomy closure technique may increase the risk of catheter migration, an issue that may be better understood with further investigation. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Electron microscopic evaluation of a gold glaucoma micro shunt after explantation.

    PubMed

    Berk, Thomas A; Tam, Diamond Y; Werner, Liliana; Mamalis, Nick; Ahmed, Iqbal Ike K

    2015-03-01

    We present a case of an explanted gold glaucoma micro shunt (GMS Plus) and the subsequent light and electron microscopic analyses. The shunt was implanted in a patient with medically refractive glaucoma. The intraocular pressure (IOP) was stable at 12 mm Hg 6 months postoperatively but spiked to 26 mm Hg 6 months later; membranous growth was visible on the implant gonioscopically. A second gold micro shunt was placed 2 years after the first. The IOP was 7 mm Hg 1 week postoperatively but increased to 23 mm Hg 3 weeks later; similar membranous growth was visible on this implant. One of the shunts was explanted, and light and scanning electron microscopic analyses revealed encapsulation around the shunt exterior and connective tissue invasion of the microstructure. This represents the first electron microscopic analysis of an explanted gold glaucoma micro shunt and the first unequivocal images of the fibrotic pseudo-capsule traversing its microchannels and fenestrations. Dr. Ahmed is a consultant to and has received research grants from Solx, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Morphology of congenital portosystemic shunts involving the left colic vein in dogs and cats.

    PubMed

    White, R N; Parry, A T

    2016-05-01

    To describe the anatomy of congenital portosystemic shunts involving the left colic vein in dogs and cats. Retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. For inclusion a shunt involving the left colic vein with recorded intraoperative mesenteric portovenography or computed tomography angiography along with direct gross surgical observations at the time of surgery was required. Six dogs and three cats met the inclusion criteria. All cases had a shunt which involved a distended left colic vein. The final communication with a systemic vein was variable; in seven cases (five dogs, two cats) it was via the caudal vena cava, in one cat it was via the common iliac vein and in the remaining dog it was via the internal iliac vein. In addition, two cats showed caudal vena cava duplication. The morphology of this shunt type appeared to be a result of an abnormal communication between either the left colic vein or the cranial rectal vein and a pelvic systemic vein (caudal vena cava, common iliac vein or internal iliac vein). This information may help with surgical planning in cases undergoing shunt closure surgery. © 2016 British Small Animal Veterinary Association.

  19. Successful transcatheter closure of a congenital high-flow portosystemic venous shunt with the Amplatzer vascular plug II.

    PubMed

    Guneyli, Serkan; Cinar, Celal; Bozkaya, Halil; Parildar, Mustafa; Oran, Ismail; Akin, Yigit

    2012-12-01

    Congenital portosystemic venous shunt is extremely rare and should be treated. Advances in treatment techniques allow for patients to be treated safely. We present a 9-year-old boy with a large congenital portosystemic venous shunt. The shunt was occluded interventionally with the Amplatzer vascular plug II. Our case was unique with its clinical manifestation, the use of a 22-mm Amplatzer vascular plug II, and the presence of the patient's 1-year follow-up.

  20. Clopidogrel in infants with systemic-to-pulmonary-artery shunts.

    PubMed

    Wessel, David L; Berger, Felix; Li, Jennifer S; Dähnert, Ingo; Rakhit, Amit; Fontecave, Sylvie; Newburger, Jane W

    2013-06-20

    Infants with cyanotic congenital heart disease palliated with placement of a systemic-to-pulmonary-artery shunt are at risk for shunt thrombosis and death. We investigated whether the addition of clopidogrel to conventional therapy reduces mortality from any cause and morbidity related to the shunt. In a multicenter, double-blind, event-driven trial, we randomly assigned infants 92 days of age or younger with cyanotic congenital heart disease and a systemic-to-pulmonary-artery shunt to receive clopidogrel at a dose of 0.2 mg per kilogram of body weight per day (467 infants) or placebo (439 infants), in addition to conventional therapy (including aspirin in 87.9% of infants). The primary efficacy end point was a composite of death or heart transplantation, shunt thrombosis, or performance of a cardiac procedure due to an event considered to be thrombotic in nature before 120 days of age. The rate of the composite primary end point did not differ significantly between the clopidogrel group (19.1%) and the placebo group (20.5%) (absolute risk difference, 1.4 percentage points; relative risk reduction with clopidogrel, 11.1%; 95% confidence interval, -19.2 to 33.6; P=0.43), nor did the rates of the three components of the composite primary end point. There was no significant benefit of clopidogrel treatment in any subgroup, including subgroups defined by shunt type. Clopidogrel recipients and placebo recipients had similar rates of overall bleeding (18.8% and 20.2%, respectively) and severe bleeding (4.1% and 3.4%, respectively). Clopidogrel therapy in infants with cyanotic congenital heart disease palliated with a systemic-to-pulmonary-artery shunt, most of whom received concomitant aspirin therapy, did not reduce either mortality from any cause or shunt-related morbidity. (Funded by Sanofi-Aventis and Bristol-Myers Squibb; ClinicalTrials.gov number, NCT00396877.).

  1. Deriving the Intrahepatic Arteriovenous Shunt Rate from CT Images and Biochemical Data Instead of from Arterial Perfusion Scintigraphy in Hepatic Arterial Infusion Chemotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ozaki, Toshiro, E-mail: ganronbun@amail.plala.or.jp; Seki, Hiroshi; Shiina, Makoto

    2009-09-15

    The purpose of the present study was to elucidate a method for predicting the intrahepatic arteriovenous shunt rate from computed tomography (CT) images and biochemical data, instead of from arterial perfusion scintigraphy, because adverse exacerbated systemic effects may be induced in cases where a high shunt rate exists. CT and arterial perfusion scintigraphy were performed in patients with liver metastases from gastric or colorectal cancer. Biochemical data and tumor marker levels of 33 enrolled patients were measured. The results were statistically verified by multiple regression analysis. The total metastatic hepatic tumor volume (V{sub metastasized}), residual hepatic parenchyma volume (V{sub residual};more » calculated from CT images), and biochemical data were treated as independent variables; the intrahepatic arteriovenous (IHAV) shunt rate (calculated from scintigraphy) was treated as a dependent variable. The IHAV shunt rate was 15.1 {+-} 11.9%. Based on the correlation matrixes, the best correlation coefficient of 0.84 was established between the IHAV shunt rate and V{sub metastasized} (p < 0.01). In the multiple regression analysis with the IHAV shunt rate as the dependent variable, the coefficient of determination (R{sup 2}) was 0.75, which was significant at the 0.1% level with two significant independent variables (V{sub metastasized} and V{sub residual}). The standardized regression coefficients ({beta}) of V{sub metastasized} and V{sub residual} were significant at the 0.1 and 5% levels, respectively. Based on this result, we can obtain a predicted value of IHAV shunt rate (p < 0.001) using CT images. When a high shunt rate was predicted, beneficial and consistent clinical monitoring can be initiated in, for example, hepatic arterial infusion chemotherapy.« less

  2. Clinical outcomes of temporary shunting for infants with cerebral pseudomeningocele.

    PubMed

    Mattei, Tobias A; Sambhara, Deepak; Bond, Brandon J; Lin, Julian

    2014-02-01

    Although in the case of subdural collections temporary shunting has been suggested as a viable alternative for definitive drainage of the accumulated fluid until restoration of the normal CSF dynamics, there is no agreement on the best management strategy for pseudomeningocele. The authors performed a retrospective chart review in order to evaluate the clinical outcomes of infants temporarily shunted for pseudomeningocele without encephalocele at our institution (The University of Illinois at Peoria/Illinois Neurological Institute) in the period from 2004 to 2012. The epidemiological characteristics, clinical management, and final outcomes of such subpopulation were compared with a control group which received temporary shunting for subdural hematomas (SDH) during the same period. Four patients (100% male) ranging in age from 8.9 to 27.1 months (mean = 13.88) with pseudomeningocele and 17 patients (64.7% male) ranging in age from 1.9 to 11.8 months (mean = 4.15) with SDH were identified. Although the initial management included sequential percutaneous subdural tapping in 82% of the patients, all children ultimately failed such strategy, requiring either subdural-peritoneal (81% of the cases) or subgaleal-peritoneal (19% of the cases) shunting. The mean implant duration was 201 days for the pseudomeningocele group and 384 days for the SDH one. Mean post-shunt hospitalization was 2 days for patients with pseudomeningocele and 4 days for patients with SDH. There was no statistical difference in terms of complications, length of hospitalization post-shunting, or clinical outcomes between the patients with pseudomeningocele and those with SDH. Temporary shunting of infants with pseudo-meningocele constitutes a viable therapeutic alternative with favorable clinical outcomes and a low risk of shunt dependency similar to those of children with SDH.

  3. Vibration attenuations induced by periodic arrays of piezoelectric patches connected by enhanced resonant shunting circuits

    NASA Astrophysics Data System (ADS)

    Wang, Gang; Wang, Jianwei; Chen, Shengbing; Wen, Jihong

    2011-12-01

    Periodic arrays of piezoelectric patches connected by enhanced resonant shunting circuits are attached to a slender beam to control the propagation of vibration. Numerical models based on the transfer matrix methodology are constructed to predict the band structure, attenuation factors and the transmission of vibration in the proposed smart structure. The vibration attenuations of the proposed smart structure and that with the passive resonant shunting circuits are compared in order to verify the efficiency of the enhanced resonant shunting circuits. Vibration experiments are conducted in order to validate the theoretical predictions. The specimen with a combination of different types of resonant shunting circuits is also studied in order to gain wider attenuation frequency ranges.

  4. The internal mammary artery as a shunt in a noncyanotic infant with hemitruncus: surgical and anesthetic management.

    PubMed

    Mahan, Vicki L; Stevens, Randy M; Mesia, Cesar I; Schwartz, Roy E; Moulick, Achintya N

    2016-08-01

    The internal mammary artery (IMA) has been used as a systemic-to-pulmonary artery shunt in selected patients with congenital heart disease. Growth and development of hypoplastic pulmonary arteries have been described. We discuss the surgical and anesthetic management of an infant with an atretic-thrombosed right pulmonary artery originating from the ascending aorta in whom the IMA was used to create a systemic-to-pulmonary artery shunt after failure of a previous shunt and later successful pulmonary artery reconstruction. The IMA should be considered as an alternative conduit in patients requiring a systemic-to-pulmonary artery shunt for growth of pulmonary arteries. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Congenital extrahepatic portosystemic shunt (Abernethy malformation) treated endovascularly with vascular plug shunt closure.

    PubMed

    Passalacqua, Matthew; Lie, Kevin T; Yarmohammadi, Hooman

    2012-01-01

    A 3-year-old boy, who presented with progressive cyanosis and hypoxia, was diagnosed with a large congenital extrahepatic portosystemic shunt, interrupted IVC with azygos continuation, and multiple congenital anomalies. Traditionally open and laparoscopic surgical techniques have been used to treat this malformation. Endovascular repair using a 16-mm Amplatzer vascular plug (AGA Medical Corporation, Golden Valley, Minnesota, USA) was used to occlude the shunt. Immediate post-placement venography demonstrated cessation of flow within the shunt and increased portal venous flow. The patient's hypoxia and cyanosis decreased significantly, and he was discharged on the 5th post-procedure day in stable clinical condition. Three months follow-up evaluation demonstrated the vascular plug in place, unchanged in position.

  6. Congenital Intrahepatic Portosystemic Venous Shunt and Liver Mass in a Child Patient: Successful Endovascular Treatment with an Amplatzer Vascular Plug (AVP)

    PubMed Central

    Lee, Sae Ah; Lee, Young Seok; Lee, Kun Song

    2010-01-01

    A congenital intrahepatic portosystemic shunt is a rare anomaly; but, the number of diagnosed cases has increased with advanced imaging tools. Symptomatic portosystemic shunts, especially those that include hyperammonemia, should be treated; and various endovascular treatment methods other than surgery have been reported. Hepatic masses with either an intra- or extrahepatic shunt also have been reported, and the mass is another reason for treatment. Authors report a case of a congenital intrahepatic portosystemic shunt with a hepatic mass that was successfully treated using a percutaneous endovascular approach with vascular plugs. By the time the first short-term follow-up was conducted, the hepatic mass had disappeared. PMID:20808706

  7. Two cases of esophageal cancer with portal hypertension: esophagectomy with venous shunt procedure.

    PubMed

    Kato, T; Motohara, T; Kaneko, Y; Shikishima, H; Okushiba, S; Kondo, S; Kato, H

    2001-01-01

    We performed venous shunt procedure in the reconstruction of the esophagus after esophagectomy using the gastric tube in two cases of esophageal cancer with portal hypertension due to liver cirrhosis. In both cases, the short-term postoperative course was uneventful, without congestion in the gastric tube. In Case 1 where the short gastric vein had been used as the shunt vein, the long-term postoperative course was also uneventful, without hepatic encephalopathy or hemorrhage from deterioration of the varices of the gastric tube. However, in Case 2 where the left gastroepiploic vein had been used, hepatic encephalopathy developed due to excessive shunt flow. These results suggested that appropriate shunt flow could be expected by using short gastric vein.

  8. Robust Electrical Transfer System (RETS) for Solar Array Drive Mechanism SlipRing Assembly

    NASA Astrophysics Data System (ADS)

    Bommottet, Daniel; Bossoney, Luc; Schnyder, Ralph; Howling, Alan; Hollenstein, Christoph

    2013-09-01

    Demands for robust and reliable power transmission systems for sliprings for SADM (Solar Array Drive Mechanism) are increasing steadily. As a consequence, it is required to know their performances regarding the voltage breakdown limit.An understanding of the overall shape of the breakdown voltage versus pressure curve is established, based on experimental measurements of DC (Direct Current) gas breakdown in complex geometries compared with a numerical simulation model.In addition a detailed study was made of the functional behaviour of an entire wing of satellite in a like- operational mode, comprising the solar cells, the power transmission lines, the SRA (SlipRing Assembly), the power S3R (Sequential Serial/shunt Switching Regulators) and the satellite load to simulate the electrical power consumption.A test bench able to measure automatically the: a)breakdown voltage versus pressure curve and b)the functional switching performances, was developed and validated.

  9. Congenital intrahepatic portohepatic venous shunt: treatment with coil embolisation.

    PubMed

    Kim, I O; Cheon, J E; Kim, W S; Chung, J W; Yeon, K M; Yoo, S J; Seo, J K; Choi, J H

    2000-05-01

    Congenital abnormalities of the portal venous system are rare. There are few radiological descriptions of intrahepatic portosystemic venous shunt detected in the perinatal period. We report a congenital portosystemic shunt that was detected by US and treated with coil embolisation in the neonatal period.

  10. Aqueous shunt implantation in glaucoma

    PubMed Central

    Wang, Jing; Barton, Keith

    2017-01-01

    Aqueous shunts or glaucoma drainage devices are increasingly utilized in the management of refractory glaucoma. The general design of the most commonly-used shunts is based on the principles of the Molteno implant: ie. a permanent sclerostomy (tube), a predetermined bleb area (plate) and diversion of aqueous humour to the equatorial region and away from the limbal subconjunctival space. These three factors make aqueous shunts more resistant to scarring as compared to trabeculectomy. The two most commonly used shunts are the Ahmed Glaucoma Valve, which contains a flow-restrictor, and the non-valved Baervedlt Glaucoma Implant. While the valved implants have a lower tendency to hypotony and related complications, the non-valved implants with larger, more-biocompatible end plate design, achieve lower intraocular pressures with less encapsulation. Non-valved implants require additional suturing techniques to prevent early hypotony and a number of these methods will be described. Although serious shunt-related infection is rare, corneal decompensation and diplopia are small but significant risks. PMID:29034151

  11. The long-term prognosis of congenital portosystemic venous shunt.

    PubMed

    Uchino, T; Matsuda, I; Endo, F

    1999-08-01

    Congenital portosystemic venous shunt (PSVS), considered to be a rare disease, can lead to hepatic encephalopathy (HE). With improvements in diagnostic imaging techniques, the number of infants and children with documented PSVS has increased. The natural course of the disease and indications for surgical closure of the shunt vessel have not been well defined. We reviewed 51 cases of congenital PSVS in Japan; 34 patients had an intrahepatic PSVS, and 17 had an extrahepatic PSVS. There were 12 patients with HE at the time of diagnosis. The frequency of HE increased in subjects over 60 years of age. Children with HE had a shunt ratio exceeding 60%. When the shunt ratio was less than 30%, HE did not occur. Twenty of 28 patients under the age of 15 years had hypergalactosemia at the time of neonatal screening. Part of the congenital intrahepatic PSVS spontaneously closed. Surgical closure of a PSVS may be an approach expected to prevent HE when the shunt ratio exceeds 60%.

  12. Thinking outside the shunt-sterile CSF malabsorption in pilocytic astrocytomas: case series and review of the literature.

    PubMed

    Johnson, J A; O'Halloran, P J; Crimmins, D; Caird, J

    2016-11-01

    Ventriculoperitoneal (VP) shunt insertion is the most common cerebrospinal fluid (CSF) diversionary procedure used for the treatment of chronic hydrocephalus. Sterile CSF ascites is a rare complication of VP shunt insertion. This can arise from either an overproduction of CSF or inadequate filtration of CSF at the level of the peritoneum. By either mechanism, the development of CSF ascites requires an intact VP shunt. The authors discuss two paediatric cases diagnosed with suprasellar pilocytic astrocytomas treated with platinum-based chemotherapy, who subsequently developed sterile CSF ascites. We review the literature with regard to CSF malabsorption and discuss it as a contributing factor to shunt malfunction. CSF malabsorption with resultant ascites is a rare complication of VP shunting with many etiologies. Two common predisposing factors included the use of platinum-based chemotherapeutic agents, as well as the specific neuropathology. Further analysis of these two entities is needed in order to elucidate their role in contributing to the development of CSF ascites in this patient cohort.

  13. Distal splenorenal shunt

    MedlinePlus

    ... through your nose into your stomach to remove gas and fluids A pump with a button you can press when you need pain medicine As you are able to eat and drink, you will be given liquids and food. You may have an imaging test ...

  14. Venous Shunt Versus Venous Ligation for Vascular Damage Control: The Immunohistochemical Evidence.

    PubMed

    Góes Junior, Adenauer Marinho de Oliveira; Abib, Simone de Campos Vieira; Alves, Maria Teresa de Seixas; Ferreira, Paulo Sérgio Venerando da Silva; Andrade, Mariseth Carvalho de

    2017-05-01

    To evaluate the expression of immunohistochemical markers of tissue ischemia (iNOS, eNOS, and HSP70) in a vascular damage control experimental model to determine if a venous temporary vascular shunt insertion leads to a better limb perfusion when compared with the ligature of the injured vein. Experimental study in male Sus Scrofa weighting 40 Kg. Animals were distributed into 5 groups: group 1 animals were submitted to right external iliac artery (EIA) shunting and right external iliac vein (EIV) ligation; group 2 animals were submitted to right EIA shunting and right EIV shunting; group 3 animals were submitted to right EIV ligation; group 4 animals were submitted to right EIV shunting; group 5 animals were not submitted to vascular shunting or venous ligation. Transonic Systems flowmeters were used to measure vascular flow on right and left external iliac vessels, and i-STAT (Abbot) portable blood analyzer was used for EIVs blood biochemical analysis. An initial baseline register of invasive arterial pressure, iliac vessels flow, and venous blood analysis was performed. Arterial pressure and iliac vessels flow were taken immediately after right iliac vessels shunting or ligation. Then, hemorrhagic shock was induced by continuous 20 mL/min blood withdraw from the external right jugular vein whereas arterial blood pressure and iliac vessels flow registers were taken every 10 min, and blood samples from EIVs were obtained every 30 min until the vascular flow through right EIA (or through the shunt inserted into the right EIV for group 4 animals) became inexistent or until the animal's death. After the end of the experiments, bilateral hind limb's biopsies were obtained for immunohistochemical analysis. Using image editing and analysis software, the expression of iNOS, eNOS, and HSP70 (3 well-known ischemic associated immunohistochemical markers) was assessed. The mean expression of each marker in the right hind limb was compared between groups. For statistical analysis, Microsoft Office Excel 2007 and BioEstat 5.0 (2007) were used. Immunohistochemical analysis showed no difference regarding the iNOS expression; nevertheless, both eNOS and HSP70 expression were statistically more intense (P < 0.05) on group 1 (eNOS = 1.32; HSP70 = 15.05) than on group 2 (eNOS = 0.018; HSP70 = 8.56). The higher expression of eNOS and HSP70 in the right hind limbs of group 1 animals (arterial shunt and venous ligature) than group 2 animals (arterial shunt and venous shunt) suggests that venous ligation is associated with more intense ischemic histological findings than venous shunting. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Early variations of laboratory parameters predicting shunt-dependent hydrocephalus after subarachnoid hemorrhage.

    PubMed

    Na, Min Kyun; Won, Yu Deok; Kim, Choong Hyun; Kim, Jae Min; Cheong, Jin Hwan; Ryu, Je Il; Han, Myung-Hoon

    2017-01-01

    Hydrocephalus is a frequent complication following subarachnoid hemorrhage. Few studies investigated the association between laboratory parameters and shunt-dependent hydrocephalus. This study aimed to investigate the variations of laboratory parameters after subarachnoid hemorrhage. We also attempted to identify predictive laboratory parameters for shunt-dependent hydrocephalus. Multiple imputation was performed to fill the missing laboratory data using Bayesian methods in SPSS. We used univariate and multivariate Cox regression analyses to calculate hazard ratios for shunt-dependent hydrocephalus based on clinical and laboratory factors. The area under the receiver operating characteristic curve was used to determine the laboratory risk values predicting shunt-dependent hydrocephalus. We included 181 participants with a mean age of 54.4 years. Higher sodium (hazard ratio, 1.53; 95% confidence interval, 1.13-2.07; p = 0.005), lower potassium, and higher glucose levels were associated with higher shunt-dependent hydrocephalus. The receiver operating characteristic curve analysis showed that the areas under the curve of sodium, potassium, and glucose were 0.649 (cutoff value, 142.75 mEq/L), 0.609 (cutoff value, 3.04 mmol/L), and 0.664 (cutoff value, 140.51 mg/dL), respectively. Despite the exploratory nature of this study, we found that higher sodium, lower potassium, and higher glucose levels were predictive values for shunt-dependent hydrocephalus from postoperative day (POD) 1 to POD 12-16 after subarachnoid hemorrhage. Strict correction of electrolyte imbalance seems necessary to reduce shunt-dependent hydrocephalus. Further large studies are warranted to confirm our findings.

  16. An adaptive metamaterial beam with hybrid shunting circuits for extremely broadband control of flexural wave (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Chen, Yangyang; Huang, Guoliang

    2017-04-01

    A great deal of research has been devoted to controlling the dynamic behaviors of phononic crystals and metamaterials by directly tuning the frequency regions and/or widths of their inherent band gaps. Here, we present a novel approach to achieve extremely broadband flexural wave/vibration attenuation based on tunable local resonators made of piezoelectric stacks shunted by hybrid negative capacitance and negative inductance circuits with proof masses attached on a host beam. First, wave dispersion relations of the adaptive metamaterial beam are calculated analytically by using the transfer matrix method. The unique modulus tuning properties induced by the hybrid shunting circuits are then characterized conceptually, from which the frequency dependent modulus tuning curves of the piezoelectric stack located within wave attenuation frequency regions are quantitatively identified. As an example, a flexural wave high-pass band filter with a wave attenuation region from 0 to 23.0 kHz is demonstrated analytically and numerically by using the hybrid shunting circuit, in which the two electric components are connected in series. By changing the connection pattern to be parallel, another super wide wave attenuation region from 13.5 to 73.0 kHz is demonstrated to function as a low-pass filter at a subwavelength scale. The proposed adaptive metamaterial possesses a super wide band gap created both naturally and artificially. Therefore, it can be used for the transient wave mitigation at extremely broadband frequencies such as blast or impact loadings. We envision that the proposed design and approach can open many possibilities in broadband vibration and wave control.

  17. 21 CFR 882.4545 - Shunt system implantation instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shunt system implantation instrument. 882.4545 Section 882.4545 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4545 Shunt system...

  18. 21 CFR 882.4545 - Shunt system implantation instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Shunt system implantation instrument. 882.4545 Section 882.4545 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4545 Shunt system...

  19. Ligation versus no ligation of spontaneous portosystemic shunts during liver transplantation: Audit of a prospective series of 66 consecutive patients.

    PubMed

    Gomez Gavara, Concepcion; Bhangui, Prashant; Salloum, Chady; Osseis, Michael; Esposito, Francesco; Moussallem, Toufic; Lahat, Eylon; Fuentes, Liliana; Compagnon, Philippe; Ngongang, Norbert; Lim, Chetana; Azoulay, Daniel

    2018-04-01

    The management of large spontaneous portosystemic shunt (SPSS) during liver transplantation (LT) is a matter of debate. The aim of this study is to compare the short-term and longterm outcomes of SPSS ligation versus nonligation during LT, when both options are available. From 2011 to 2017, 66 patients with SPSS underwent LT: 56 without and 10 with portal vein thrombosis (PVT), all of whom underwent successful thrombectomy and could have portoportal reconstruction. The SPSS were either splenorenal (n = 40; 60.6%), left gastric (n = 16; 24.2%), or mesenterico-iliac (n = 10; 15.1%). Following portoportal anastomosis, the SPSS was ligated in 36 (54.4%) patients and left in place in 30 (45.5%) patients, based on the effect of the SPSS clamping/unclamping test on portal vein flow during the anhepatic phase. Intraoperatively, satisfactory portal flow was obtained in both groups. Primary nonfunction (PNF) and primary dysfunction (PDF) rates did not differ significantly between the 2 groups. Nonligation of SPSS was significantly associated with a higher rate of postoperative encephalopathy (P < 0.001) and major postoperative morbidity (P = 0.02). PVT occurred in 0 and 3 patients in the ligated and nonligated shunt group, respectively (P = 0.08). A composite end point, which included the relevant complications in the setting of SPSS in LT (ie, PNF and PDF, PVT, and encephalopathy) was present in 16 (44.4%) and 22 (73.3%) patients of the ligated and nonligated shunt group, respectively (P = 0.02). Patient (P = 0.05) and graft (P = 0.02) survival rates were better in the ligated shunt group. In conclusion, the present study supports routine ligation of large SPSS during LT whenever feasible. Liver Transplantation 24 505-515 2018 AASLD. © 2018 by the American Association for the Study of Liver Diseases.

  20. Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Bezzi, Mario; Bruni, Antonio

    2011-02-15

    We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findingsmore » and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.« less

  1. Intracranial pressure monitoring in pediatric and adult patients with hydrocephalus and tentative shunt failure: a single-center experience over 10 years in 146 patients.

    PubMed

    Sæhle, Terje; Eide, Per Kristian

    2015-05-01

    OBJECT In patients with hydrocephalus and shunts, lasting symptoms such as headache and dizziness may be indicative of shunt failure, which may necessitate shunt revision. In cases of doubt, the authors monitor intracranial pressure (ICP) to determine the presence of over- or underdrainage of CSF to tailor management. In this study, the authors reviewed their experience of ICP monitoring in shunt failure. The aims of the study were to identify the complications and impact of ICP monitoring, as well as to determine the mean ICP and characteristics of the cardiac-induced ICP waves in pediatric versus adult over- and underdrainage. METHODS The study population included all pediatric and adult patients with hydrocephalus and shunts undergoing diagnostic ICP monitoring for tentative shunt failure during the 10-year period from 2002 to 2011. The patients were allocated into 3 groups depending on how they were managed following ICP monitoring: no drainage failure, overdrainage, or underdrainage. While patients with no drainage failure were managed conservatively without further actions, over- or underdrainage cases were managed with shunt revision or shunt valve adjustment. The ICP and ICP wave scores were determined from the continuous ICP waveforms. RESULTS The study population included 71 pediatric and 75 adult patients. There were no major complications related to ICP monitoring, but 1 patient was treated for a postoperative superficial wound infection and another experienced a minor bleed at the tip of the ICP sensor. Following ICP monitoring, shunt revision was performed in 74 (51%) of 146 patients, while valve adjustment was conducted in 17 (12%) and conservative measures without any actions in 55 (38%). Overdrainage was characterized by a higher percentage of episodes with negative mean ICP less than -5 to -10 mm Hg. The ICP wave scores, in particular the mean ICP wave amplitude (MWA), best differentiated underdrainage. Neither mean ICP nor MWA levels showed any significant association with age. CONCLUSIONS In this cohort of pediatric and adult patients with hydrocephalus and tentative shunt failure, the risk of ICP monitoring was very low, and helped the authors avoid shunt revision in 49% of the patients. Mean ICP best differentiated overdrainage, which was characterized by a higher percentage of episodes with negative mean ICP less than -5 to -10 mm Hg. Underdrainage was best characterized by elevated MWA values, indicative of impaired intracranial compliance.

  2. Soliton quenching NLTL impulse circuit with a pulse forming network at the output

    DOEpatents

    McEwan, Thomas E.; Dallum, Gregory E.

    1998-01-01

    An impulse forming circuit is disclosed which produces a clean impulse from a nonlinear transmission line compressed step function without customary soliton ringing by means of a localized pulse shaping and differentiating network which shunts the nonlinear transmission line output to ground.

  3. Voltage stability index based optimal placement of static VAR compensator and sizing using Cuckoo search algorithm

    NASA Astrophysics Data System (ADS)

    Venkateswara Rao, B.; Kumar, G. V. Nagesh; Chowdary, D. Deepak; Bharathi, M. Aruna; Patra, Stutee

    2017-07-01

    This paper furnish the new Metaheuristic algorithm called Cuckoo Search Algorithm (CSA) for solving optimal power flow (OPF) problem with minimization of real power generation cost. The CSA is found to be the most efficient algorithm for solving single objective optimal power flow problems. The CSA performance is tested on IEEE 57 bus test system with real power generation cost minimization as objective function. Static VAR Compensator (SVC) is one of the best shunt connected device in the Flexible Alternating Current Transmission System (FACTS) family. It has capable of controlling the voltage magnitudes of buses by injecting the reactive power to system. In this paper SVC is integrated in CSA based Optimal Power Flow to optimize the real power generation cost. SVC is used to improve the voltage profile of the system. CSA gives better results as compared to genetic algorithm (GA) in both without and with SVC conditions.

  4. Dynamics of electronic transport in spatially-extended systems with negative differential conductivity

    NASA Astrophysics Data System (ADS)

    Xu, Huidong

    Negative differential conductivity (NDC) is a nonlinear property of electronic transport for high electric field strength found in materials and devices such as semiconductor superlattices, bulk GaAs and Gunn diodes. In spatially extended systems, NDC can cause rich dynamics such as static and mobile field domains and moving charge fronts. In this thesis, these phenomena are studied theoretically and numerically for semiconductor superlattices. Two classes of models are considered: a discrete model based on sequential resonant tunneling between neighboring quantum wells is used to described charge transport in weakly-coupled superlattices, and a continuum model based on the miniband transport is used to describe charge transport strongly-coupled superlattices. The superlattice is a spatially extended nonlinear system consisting a periodic arrangement of quantum wells (e.g., GaAs) and barriers (e.g., AlAs). Using a discrete model and only considering one spatial dimension, we find that the boundary condition at the injecting contact has a great influence on the dynamical behavior for both fixed voltage and transient response. Static or moving field domains are usually inevitable in this system. In order to suppress field domains, we add a side shunting layer parallel to the growth direction of the superlattice. In this case, the model includes both vertical and lateral spatial degrees of freedom. We first study a shunted weakly-coupled superlattice for a wide range of material parameters. The field domains are found to be suppressed for superlattices with small lateral size and good connection between the shunt and the quantum wells of the superlattice. As the lateral size of the superlattice increases, the uniform field configuration loses its stability to either static or dynamic field domains, regardless of shunt properties. A lower quality shunt generally leads to regular and chaotic current oscillations and complex spatio-temporal dynamics in the field profile. Bifurcations separating static and dynamic behaviors are characterized and found to be dependent on the shunt properties. Then we adopt the model to study the shunted strongly-coupled superlattice with the continuum model. Key structural parameters associated with both the shunt layer and SL are identified for which the shunt layer stabilizes a uniform electric field profile. These results support the possibility to realize a SL-based THz oscillator with a carefully designed structure. Another important behavior of the static field domains in the weakly-coupled superlattice is bistability, i.e., two possible states (i.e., electric field configurations) for a single voltage. Noise can drive the system from one of these states (the metastable state) to the other one (the globally stable state). The process of escape from the metastable state can be viewed as a stochastic first-passage process in a high-dimensional system that possesses complex stability eigenvalues and for which a global potential energy function does not exist. This process is simulated using a stochastic differential equation system which incorporates shot noise. The mean switching time tau is fitted to an exponential expression e1DVth -Va, where Vth denotes the voltage at the end of the current branch. The exponent alpha in the fitting curve deviates from 1.5 which is predicted for a generic one dimensional system. We develop an algorithm to determine an effective locally valid potential. Principal component analysis is applied to find the most probable path for switching from the metastable current state.

  5. Impact of Serum Vancomycin Trough Levels in the Treatment of Central Nervous System Shunt Infections Caused by Coagulase-Negative Staphylococci.

    PubMed

    Gibson, Ashley; Kaplan, Sheldon L; Vallejo, Jesus G

    2018-04-26

    Coagulase-negative staphylococci (CoNS) are a common cause of pediatric ventricular shunt infections. The Infectious Diseases Society of America recommends vancomycin serum troughs of 15-20 µg/mL when treating CoNS shunt infections in adult patients. We report a series of pediatric cases of CoNS shunt infections in which clinical cure was obtained with troughs < 15 µg/mL. These findings question the relevance of this recommendation in pediatric patients. © 2018 S. Karger AG, Basel.

  6. Canine congenital portosystemic shunts: Disconnections dissected.

    PubMed

    Van den Bossche, L; van Steenbeek, F G

    2016-05-01

    Canine congenital portosystemic shunts (CPSS) are vascular anomalies that connect the portal vein with the systemic circulation, therefore bypassing the hepatic parenchyma. Portosystemic shunts exist in two different subtypes: extrahepatic and intrahepatic. This congenital disorder is also described in mice, cat, sheep and man. Research has been focused on pathophysiology, diagnostics and treatment of CPSS and this has resulted in increased knowledge, although the aetiology of the disease remains unclear. This review focuses on the aetiology and genetic basis of both intra- and extrahepatic shunts. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Reduction of ventricular size after shunting for normal pressure hydrocephalus related to CSF dynamics before shunting.

    PubMed Central

    Tans, J T; Poortvliet, D C

    1988-01-01

    Reduction of ventricular size was determined by repeated computed tomography in 30 adult patients shunted for normal pressure hydrocephalus (NPH) and related to the pressure-volume index (PVI) and resistance to outflow of cerebrospinal fluid (Rcsf) measured before shunting. Rapid and marked reduction of ventricular size (n = 10) was associated with a significantly lower PVI than slow and moderate to marked (n = 13) or minimal to mild reduction (n = 7). Otherwise no relationship could be found between the reduction of ventricular size and PVI or Rcsf. It is concluded that both rate and magnitude of reduction of ventricular size after shunting for NPH are extremely variable. High brain elasticity seems to be the best predictor of rapid and marked reduction. PMID:3379425

  8. Use of intraoperative mesenteric portovenography in congenital portosystemic shunt surgery.

    PubMed

    White, Robert N; Macdonald, Nicholas J; Burton, Carolyn A

    2003-01-01

    A retrospective study of the use of intraoperative mesenteric portovenography (IOMP) in the surgical management of congenital portosystemic shunts in 100 dogs and cats was performed. Each portovenogram was scored using a subjective visual analogue scale (VAS) and was assessed for the presence of portal atresia or hypoplasia. VAS scores and portal hypoplasia assessments were obtained for portovenogram images obtained for each animal both before shunt manipulation (preligation) and following the temporary, complete ligation of the vessel (postligation). In each patient, surgical records were reviewed to ascertain the degree of shunt attenuation that was achieved at surgery. Hepatic portal vasculature was significantly different on postligation compared with preligation IOMP. Sixty-two percent of animals had apparent portal hypoplasia or atresia on their preligation IOMP. The majority of these (81%) had an improvement in portal vasculature on postligation IOMP. It was concluded that both preligation and postligation IOMP provided valuable information regarding the morphology of congenital portosystemic shunts. An accurate assessment of an animal's portal vasculature could only be made following the interpretation of a postligation portovenogram, and these findings significantly influenced the surgical management of the patient. Although individuals with high postligation VAS scores were more likely to achieve full shunt attenuation at surgery, there was no quantifiable relationship between IOMP findings and the degree of shunt attenuation achieved.

  9. Intracranial Pressure-Guided Shunt Valve Adjustments with the Miethke Sensor Reservoir.

    PubMed

    Antes, Sebastian; Stadie, Axel; Müller, Simon; Linsler, Stefan; Breuskin, David; Oertel, Joachim

    2018-01-01

    Telemetric intracranial pressure (ICP) monitoring seems to be a promising therapy-supporting option in shunt-treated patients. Benefits become obvious when headaches are unspecific and clinical symptoms cannot be related to possible overdrainage or underdrainage. In this study, we evaluated a new telemetric device to individually adjust shunt valves according to ICP measurements. Between December 2015 and November 2016, 25 patients with suspected suboptimal shunt valve settings underwent insertion of a telemetric ICP sensor (Sensor Reservoir; Christoph Miethke, Potsdam, Germany). Over a 1-year period, a total of 183 telemetric ICP measurements and 85 shunt valve adjustments were carried out. Retrospective statistic analyses focused on valve adjustments, ICP values, and clinical outcomes. ICP-guided valve adjustments positively changed the clinical state in 18 out of 25 patients. Clinical improvement over time was associated with significant changes of the valve settings and ICP values. Interestingly, a therapeutically normalized ICP profile was not automatically associated with clinical improvement. The Sensor Reservoir is an important and valuable tool for shunt-treated patients suffering from drainage-related problems. The possibility to simultaneously recognize and solve shunt problems represents the decisive advantage. Nevertheless, measurements with the Sensor Reservoir did not allow for the determination of default valve settings or universal target ICP values. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Failed Ventriculoperitoneal Shunt: Is Retrograde Ventriculosinus Shunt a Reliable Option?

    PubMed

    Oliveira, Matheus Fernandes de; Teixeira, Manoel Jacobsen; Reis, Rodolfo Casimiro; Petitto, Carlo Emanuel; Gomes Pinto, Fernando Campos

    2016-08-01

    Currently, the treatment of hydrocephalus is mainly carried out through a ventriculoperitoneal shunt (VPS) insertion. However, in some cases, there may be surgical revisions and requirement of an alternative distal site for shunting. There are several described distal sites, and secondary options after VPS include ventriculopleural and ventriculoatrial shunt, which have technical difficulties and harmful complications. In this preliminary report we describe our initial experience with retrograde ventriculosinus shunt (RVSS) after failed VPS. In 3 consecutive cases we applied RVSS to treat hydrocephalus in shunt-dependent patients who had previously undergone VPS revision and in which peritoneal space was full of adhesions and fibrosis. RVSS was performed as described by Shafei et al., with some modifications to each case. All 3 patients kept the same clinical profile after RVSS, with no perioperative or postoperative complications. However, revision surgery was performed in the first operative day in 1 out of 3 patients, in which the catheter was not positioned in the superior sagittal sinus. We propose that in cases where VPS is not feasible, RVSS may be a safe and applicable second option. Nevertheless, the long-term follow-up of patients and further learning curve must bring stronger evidence. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Correlation between liver volume, portal vascular anatomy, and hepatic perfusion in dogs with congenital portosystemic shunt before and after placement of ameroid constrictors.

    PubMed

    Zwingenberger, Allison L; Daniel, Leticia; Steffey, Michele A; Mayhew, Philipp D; Mayhew, Kelli N; Culp, William T N; Hunt, Geraldine B

    2014-11-01

    To correlate changes in hepatic volume, hepatic perfusion, and vascular anatomy of dogs with congenital extrahepatic portosystemic shunts, before and after attenuation with an ameroid constrictor. Prospective study. Dogs (n = 22) with congenital extrahepatic portosystemic shunts. CT angiography and perfusion scans were performed before and after attenuation of a portosystemic shunt with an ameroid constrictor. Changes in hepatic volume, hepatic perfusion, and vascular anatomy were measured. Portal scintigraphy was performed in 8 dogs preoperatively and 22 dogs postoperatively. Dogs with smaller preoperative liver volumes had greater increases in liver volume postoperatively compared with those with larger preoperative liver volumes. Hepatic arterial fraction was increased in dogs preoperatively and returned to normal range after shunt attenuation, and was correlated with increase in liver size and decreased shunt fraction. Three dogs with no visible portal vasculature preoperatively developed portal branches postoperatively. Dogs with smaller preoperative liver volumes had the largest postoperative increase in liver volume. Hepatic arterial perfusion and portal scintigraphy correlate with liver volume and are indicators of successful shunt attenuation. Dogs without visible vasculature on CT angiography had visible portal vasculature postoperatively. © Copyright 2014 by The American College of Veterinary Surgeons.

  12. Modeling the effect of shunt current on the charge transfer efficiency of an all-vanadium redox flow battery

    NASA Astrophysics Data System (ADS)

    Chen, Yong-Song; Ho, Sze-Yuan; Chou, Han-Wen; Wei, Hwa-Jou

    2018-06-01

    In an all-vanadium redox flow battery (VRFB), a shunt current is inevitable owing to the electrically conductive electrolyte that fills the flow channels and manifolds connecting cells. The shunt current decreases the performance of a VRFB stack as well as the energy conversion efficiency of a VRFB system. To understand the shunt-current loss in a VRFB stack with various designs and operating conditions, a mathematical model is developed to investigate the effects of the shunt current on battery performance. The model is calibrated with experimental data under the same operating conditions. The effects of the battery design, including the number of cells, state of charge (SOC), operating current, and equivalent resistance of the electrolytes in the flow channels and manifolds, on the shunt current are analyzed and discussed. The charge-transfer efficiency is calculated to investigate the effects of the battery design parameters on the shunt current. When the cell number is increased from 5 to 40, the charge transfer efficiency is decreased from 0.99 to a range between 0.76 and 0.88, depending on operating current density. The charge transfer efficiency can be maintained at higher than 0.9 by limiting the cell number to less than 20.

  13. Myocardial strain abnormalities in fetal congenital heart disease assessed by speckle tracking echocardiography.

    PubMed

    Germanakis, Ioannis; Matsui, Hikoro; Gardiner, Helena M

    2012-01-01

    To compare myocardial deformation patterns in fetuses with congenital heart disease (CHD) with our reference range using speckle tracking echocardiography. We prospectively stored and analyzed 4-chamber loops of 28 fetuses with CHD (median gestation 27 weeks, range 20.9-37.0). The peak longitudinal left (LVs) and right (RVs) ventricular free wall Lagrangian strain and LV/RV strain ratio were measured from Syngo VVI software- (Siemens) derived original coordinates. Strain values from the first examination were compared with normative data from the same population using ANOVA with post hoc tests and serial examinations described in 14 fetuses. Simple shunt lesions (0.82) and shunts with pulmonary stenosis or atresia (0.93) had reduced mean LV/RV strain ratios compared to normal fetuses (1.01; 95% CI 0.97-1.05). Fetuses with hypoplastic left heart had the lowest (0.29), and those with Ebstein the highest (1.55), LV:RV ratio. Serial measurements showed increased LVs in aortic coarctation and aortic stenosis, but not in one developing important mitral regurgitation. Increased right ventricular loading in a fetus developing pulmonary regurgitation was associated with increasing RVs. Myocardial strain reflects the changing physiology of fetal CHD. Speckle tracking might be a useful tool to study the progress of myocardial function in affected fetuses. Copyright © 2012 S. Karger AG, Basel.

  14. A novel post-arc current measuring equipment based on vacuum arc commutation and arc blow

    NASA Astrophysics Data System (ADS)

    Liao, Minfu; Ge, Guowei; Duan, Xiongying; Huang, Zhihui

    2017-07-01

    The paper proposes a novel post-arc current measuring equipment (NPACME), which is based on the vacuum arc commutation and magnetic arc blow. The NPACME is composed of the vacuum circuit breaker (VCB), shunt resistor, protective gap, high-precision current sensor and externally applied transverse magnetic field (ETMF). The prototype of the NPACME is designed and controlled by optical fiber communications. The vacuum arc commutation between the vacuum arc and the shunt resistor with ETMF is investigated. The test platform is established in the synthetic short-circuit test and the vacuum arc is observed by the high speed CMOS camera. The mathematic description of the vacuum arc commutation is obtained. Based on the current commutation characteristic, the parameters of the NPACME are optimized and the post-arc current is measured. The measuring result of the post-arc current is accurate with small interference and the post-arc charge is obtained. The experimental results verify that the NPACME is correct and accurate, which can be used to measure the post-arc characteristic in breaking test.

  15. A Two-Step Absorber Deposition Approach To Overcome Shunt Losses in Thin-Film Solar Cells: Using Tin Sulfide as a Proof-of-Concept Material System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steinmann, Vera; Chakraborty, Rupak; Rekemeyer, Paul H.

    2016-08-31

    As novel absorber materials are developed and screened for their photovoltaic (PV) properties, the challenge remains to reproducibly test promising candidates for high-performing PV devices. Many early-stage devices are prone to device shunting due to pinholes in the absorber layer, producing 'false-negative' results. Here, we demonstrate a device engineering solution toward a robust device architecture, using a two-step absorber deposition approach. We use tin sulfide (SnS) as a test absorber material. The SnS bulk is processed at high temperature (400 degrees C) to stimulate grain growth, followed by a much thinner, low-temperature (200 degrees C) absorber deposition. At a lowermore » process temperature, the thin absorber overlayer contains significantly smaller, densely packed grains, which are likely to provide a continuous coating and fill pinholes in the underlying absorber bulk. We compare this two-step approach to the more standard approach of using a semi-insulating buffer layer directly on top of the annealed absorber bulk, and we demonstrate a more than 3.5x superior shunt resistance Rsh with smaller standard error ..sigma..Rsh. Electron-beam-induced current (EBIC) measurements indicate a lower density of pinholes in the SnS absorber bulk when using the two-step absorber deposition approach. We correlate those findings to improvements in the device performance and device performance reproducibility.« less

  16. A modified Glenn shunt reduces right ventricular stroke work during left ventricular assist device therapy.

    PubMed

    Schiller, Petter; Vikholm, Per; Hellgren, Laila

    2016-03-01

    Right ventricular (RV) failure is a major cause of morbidity and mortality after left ventricular assist device (LVAD) placement and remains hard to predict. We hypothesized that partial surgical exclusion of the RV with a modified Glenn shunt during LVAD treatment would reduce RV stroke work. An LVAD was implanted in eight pigs and a modified Glenn shunt was constructed. A conductance pressure-volume catheter was placed in the right ventricle through the apex. Haemodynamic data and pressure-volume loops were obtained at the following time periods: (i) baseline, (ii) open shunt, (iii) LVAD with closed shunt and (iii) LVAD and open shunt. During LVAD therapy, the right atrial (RA) pressure increased from 9 mmHg (9-9) to 15 mmHg (12-15), P = 0.01. RV stroke volume increased from 30 ml (29-40) to 51 ml (42-53), P < 0.01. Also, RV stroke work increased to 708 mmHg ml (654-1193) from 535 mmHg ml (424-717), P = 0.04, compared with baseline. During LVAD therapy in combination with a Glenn shunt, the RA pressure decreased from 15 mmHg (12-15) to 10 mmHg (7-11) when compared with LVAD therapy only, P = 0.01. A decrease in RV stroke work from 708 mmHg ml (654-1193) to 465 mmHg ml (366-711), P = 0.04, was seen when the LVAD was combined with a shunt, not significantly different from the baseline value (535 mmHg ml). The developed pressure in the right ventricle decreased from 29 mmHg (26-32) to 21 mmHg (20-24), P < 0.01. The pressure-volume loops of the RV show a significant reduction of RV stroke work during the use of the shunt with LVAD treatment. A modified Glenn shunt reduced RV volumes, RV stroke work and RA pressure during LVAD therapy in an experimental model of heart failure in pigs. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  17. Impact of Cerebrospinal Fluid Shunting for Idiopathic Normal Pressure Hydrocephalus on the Amyloid Cascade

    PubMed Central

    Moriya, Masao; Miyajima, Masakazu; Nakajima, Madoka; Ogino, Ikuko; Arai, Hajime

    2015-01-01

    The aim of this study was to determine whether the improvement of cerebrospinal fluid (CSF) flow dynamics by CSF shunting, can suppress the oligomerization of amyloid β-peptide (Aβ), by measuring the levels of Alzheimer’s disease (AD)-related proteins in the CSF before and after lumboperitoneal shunting. Lumbar CSF from 32 patients with idiopathic normal pressure hydrocephalus (iNPH) (samples were obtained before and 1 year after shunting), 15 patients with AD, and 12 normal controls was analyzed for AD-related proteins and APLP1-derived Aβ-like peptides (APL1β) (a surrogate marker for Aβ). We found that before shunting, individuals with iNPH had significantly lower levels of soluble amyloid precursor proteins (sAPP) and Aβ38 compared to patients with AD and normal controls. We divided the patients with iNPH into patients with favorable (improvement ≥ 1 on the modified Rankin Scale) and unfavorable (no improvement on the modified Rankin Scale) outcomes. Compared to the unfavorable outcome group, the favorable outcome group showed significant increases in Aβ38, 40, 42, and phosphorylated-tau levels after shunting. In contrast, there were no significant changes in the levels of APL1β25, 27, and 28 after shunting. After shunting, we observed positive correlations between sAPPα and sAPPβ, Aβ38 and 42, and APL1β25 and 28, with shifts from sAPPβ to sAPPα, from APL1β28 to 25, and from Aβ42 to 38 in all patients with iNPH. Our results suggest that Aβ production remained unchanged by the shunt procedure because the levels of sAPP and APL1β were unchanged. Moreover, the shift of Aβ from oligomer to monomer due to the shift of Aβ42 (easy to aggregate) to Aβ38 (difficult to aggregate), and the improvement of interstitial-fluid flow, could lead to increased Aβ levels in the CSF. Our findings suggest that the shunting procedure can delay intracerebral deposition of Aβ in patients with iNPH. PMID:25821958

  18. Electrical performance characteristics of high power converters for space power applications

    NASA Technical Reports Server (NTRS)

    Stuart, Thomas A.; King, Roger J.

    1989-01-01

    The first goal of this project was to investigate various converters that would be suitable for processing electric power derived from a nuclear reactor. The implementation is indicated of a 20 kHz system that includes a source converter, a ballast converter, and a fixed frequency converter for generating the 20 kHz output. This system can be converted to dc simply by removing the fixed frequency converter. This present study emphasized the design and testing of the source and ballast converters. A push-pull current-fed (PPCF) design was selected for the source converter, and a 2.7 kW version of this was implemented using three 900 watt modules in parallel. The characteristic equation for two converters in parallel was derived, but this analysis did not yield any experimental methods for measuring relative stability. The three source modules were first tested individually and then in parallel as a 2.7 kW system. All tests proved to be satisfactory; the system was stable; efficiency and regulation were acceptable; and the system was fault tolerant. The design of a ballast-load converter, which was operated as a shunt regulator, was investigated. The proposed power circuit is suitable for use with BJTs because proportional base drive is easily implemented. A control circuit which minimizes switching frequency ripple and automatically bypasses a faulty shunt section was developed. A nonlinear state-space-averaged model of the shunt regulator was developed and shown to produce an accurate incremental (small-signal) dynamic model, even though the usual state-space-averaging assumptions were not met. The nonlinear model was also shown to be useful for large-signal dynamic simulation using PSpice.

  19. Is it possible to minimize overdrainage complications with gravitational units in patients with idiopathic normal pressure hydrocephalus? Protocol of the randomized controlled SVASONA Trial (ISRCTN51046698).

    PubMed

    Lemcke, J; Meier, U; Müller, C; Fritsch, M; Eymann, R; Kiefer, M; Kehler, U; Langer, N; Rohde, V; Ludwig, H-Ch; Weber, F; Remenez, V; Schuhmann, M; Stengel, D

    2010-01-01

    Overdrainage is a common complication observed after shunting patients with idiopathic normal-pressure hydrocephalus (iNPH), with an estimated incidence up to 25%. Gravitational units that counterbalance intracranial pressure changes were developed to overcome this problem. We will set out to investigate whether the combination of a programmable valve and a gravitational unit (proGAV, Aesculap/Miethke, Germany) is capable of reducing the incidence of overdrainage and improving patient-centered outcomes compared to a conventional programmable valve (Medos-Codman, Johnson & Johnson, Germany). SVASONA is a pragmatic randomized controlled trial conducted at seven centers in Germany. Patients with a high probability of iNPH (based on clinical signs and symptoms, lumbar infusion and/or tap test, cranial computed tomography [CCT]) and no contraindications for surgical drainage will randomly be assigned to receive (1) a shunt assistant valve (proGAV) or (2) a conventional, programmable shunt valve (programmable Medos-Codman).We will test the primary hypothesis that the experimental device reduces the rate of overdrainage from 25% to 10%. As secondary analyses, we will measure iNPH-specific outcomes (i.e., the Black grading scale and the NPH Recovery Rate), generic quality of life (Short Form 36), and complications and serious adverse events (SAE). One planned interim analysis for safety and efficacy will be performed halfway through the study. To detect the hypothesized difference in the incidence of overdrainage with a type I error of 5% and a type II error of 20%, correcting for multiple testing and an anticipated dropout rate of 10%, 200 patients will be enrolled.The presented trial is currently recruiting patients, with the first results predicted to be available in late 2008.

  20. Soliton quenching NLTL impulse circuit with a pulse forming network at the output

    DOEpatents

    McEwan, T.E.; Dallum, G.E.

    1998-09-08

    An impulse forming circuit is disclosed which produces a clean impulse from a nonlinear transmission line compressed step function without customary soliton ringing by means of a localized pulse shaping and differentiating network which shunts the nonlinear transmission line output to ground. 5 figs.

Top