Transdiaphragmatic Approach to Attenuate Porto-Azygos Shunts Inserting in the Thorax.
Or, Matan; Kitshoff, Adriaan; Devriendt, Nausikaa; De Ridder, Marianne; Quist-Rybachuk, Galena; de Rooster, Hilde
2016-11-01
To describe the surgical technique and document the application of a transdiaphragmatic approach to attenuate porto-azygos shunts inserting in the thoracic section of the azygos vein. Cadaveric study and prospective case series. Canine cadavers (n=6) and client-owned dogs with porto-azygos shunts inserting in the thoracic section of the azygos vein (n=9). In the cadavers, the azygos vein was filled with aqueous latex. Landmarks were established for creating a safe transdiaphragmatic approach to the caudal intrathoracic portion of the azygos vein. In the clinical cases, porto-azygos communication was diagnosed by trans-splenic portal scintigraphy. All shunts were attenuated close to their insertion site via ventral midline celiotomy and a transdiaphragmatic approach to the shunt. Perioperative complications were recorded. A 3-5 cm incision, 0.5-1 cm ventral and lateral to the level of the aortic hiatus, was made in the pars lumbalis part of the diaphragm. Stay sutures at both sides of the diaphragmatic incision were placed to open up the incision and a retractor was used to push the esophagus away from the aorta. Intrathoracic insertion of the shunt was confirmed intraoperative. Exposure of the shunt insertion site at the azygos vein was excellent in all clinical cases. No intraoperative or postoperative complications were encountered. If thoracic attenuation of a porto-azygos shunt is considered, a transdiaphragmatic approach exposes the insertion site for shunt attenuation. This approach is straightforward, without unnecessary abdominal organ manipulation, and since attenuates at the insertion, avoids missing additional contributing branches. © Copyright 2016 by The American College of Veterinary Surgeons.
Internal carotid artery rupture caused by carotid shunt insertion
Illuminati, Giulio; Caliò, Francesco G.; Pizzardi, Giulia; Vietri, Francesco
2015-01-01
Introduction Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. Presentation of case A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Discussion Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Conclusion Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. PMID:26255001
O'Halloran, Philip J; Kaliaperumal, Chandrasekaran; Caird, John
2013-01-01
Ventriculoperitoneal (VP) shunt insertion is one of the most common neurosurgical procedures for the treatment of chronic hydrocephalus. Although regarded as a relatively benign procedure, several complications including obstruction, infection and mechanical failure can be seen during the postoperative stage. Symptomatic sterile cerebrospinal fluid (CSF) ascites and hydrothoracies are rare complications of VP shunt surgery. The paucity of cases makes identifying the aetiological factors difficult, particularly without catheter tip migration. It is most likely that several factors interact to reduce the absorption of CSF. The authors discuss the case of a 5-year-old girl who developed CSF ascites and a pleural effusion after starting chemotherapy for a suprasellar pilocytic astrocytoma, 2 years post-VP shunt insertion, due to a secondary obstructive hydrocephalus. After the initial management of the presenting symptoms, the child's VP shunt was subsequently changed to a ventriculo-atrial shunt and the patient made an unremarkable recovery. We also review the literature pertaining to this rare complication, assessing identifiable risk factors and surgical management options. PMID:23396932
Johnson, J A; O'Halloran, P J; Crimmins, D; Caird, J
2016-11-01
Ventriculoperitoneal (VP) shunt insertion is the most common cerebrospinal fluid (CSF) diversionary procedure used for the treatment of chronic hydrocephalus. Sterile CSF ascites is a rare complication of VP shunt insertion. This can arise from either an overproduction of CSF or inadequate filtration of CSF at the level of the peritoneum. By either mechanism, the development of CSF ascites requires an intact VP shunt. The authors discuss two paediatric cases diagnosed with suprasellar pilocytic astrocytomas treated with platinum-based chemotherapy, who subsequently developed sterile CSF ascites. We review the literature with regard to CSF malabsorption and discuss it as a contributing factor to shunt malfunction. CSF malabsorption with resultant ascites is a rare complication of VP shunting with many etiologies. Two common predisposing factors included the use of platinum-based chemotherapeutic agents, as well as the specific neuropathology. Further analysis of these two entities is needed in order to elucidate their role in contributing to the development of CSF ascites in this patient cohort.
Clark, David J; Chakraborty, Aabir; Roebuck, Derek J; Thompson, Dominic N P
2016-07-01
Ventriculoatrial (VA) shunts are commonly used as a second-line treatment of hydrocephalus when the peritoneum is an unsuitable site for the distal catheter. Many centres now utilise ultrasound and interventional radiology techniques to aid placement of the distal catheter. The purpose of this study was to conduct a contemporary audit of VA shunting in children using interventional radiology techniques for placement of the distal catheter. A retrospective analysis of all patients who had VA shunts inserted between June 2000 and June 2010 was conducted using a prospectively updated surgical database and case notes review. Ninety-four VA shunts were inserted in 38 patients. Thirty-seven patients had been treated initially with ventriculoperitoneal (VP) shunts. Twenty-two patients required at least 1 shunt revision (58 %). The 6-month, 1- and 2-year shunt survival rates were 53, 43 and 27 %, respectively. Blockage was the commonest reason for shunt failure (68 %). The site of failure was proximal (ventricular catheter +/- valve) in 32 % and distal (atrial catheter) in 21 % of cases. The overall infection rate was 6 % per procedure and 11 % per patient. There were 7 deaths, of which 3 were shunt related. VA shunting provides a viable second-line option for shunt placement in complex hydrocephalus. The causes of shunt failure (blockage, infection and equipment failure) are similar to VP shunting though shunt survival rates are inferior to VP shunts. Ultrasound guided VA shunt placement provides a relatively safe, second-line alternative to the placement of a ventriculoperitoneal shunt when this route is unsuitable.
Lee, Lester; King, Nicolas K K; Kumar, Dinesh; Ng, Yew Poh; Rao, Jai; Ng, Huiyu; Lee, Kah Keow; Wang, Ernest; Ng, Ivan
2014-10-01
The choice of programmable or nonprogrammable shunts for the management of hydrocephalus after aneurysmal subarachnoid hemorrhage (SAH) remains undefined. Variable intracranial pressures make optimal management difficult. Programmable shunts have been shown to reduce problems with drainage, but at 3 times the cost of nonprogrammable shunts. All patients who underwent insertion of a ventriculoperitoneal shunt for hydrocephalus after aneurysmal SAH between 2006 and 2012 were included. Patients were divided into those in whom nonprogrammable shunts and those in whom programmable shunts were inserted. The rates of shunt revisions, the reasons for adjustments of shunt settings in patients with programmable devices, and the effectiveness of the adjustments were analyzed. A cost-benefit analysis was also conducted to determine if the overall cost for programmable shunts was more than for nonprogrammable shunts. Ninety-four patients underwent insertion of shunts for hydrocephalus secondary to SAH. In 37 of these patients, nonprogrammable shunts were inserted, whereas in 57 programmable shunts were inserted. Four (7%) of 57 patients with programmable devices underwent shunt revision, whereas 8 (21.6%) of 37 patients with nonprogrammable shunts underwent shunt revision (p = 0.0413), and 4 of these patients had programmable shunts inserted during shunt revision. In 33 of 57 patients with programmable shunts, adjustments were made. The adjustments were for a trial of functional improvement (n = 21), overdrainage (n = 5), underdrainage (n = 6), or overly sunken skull defect (n = 1). Of these 33 patients, 24 showed neurological improvements (p = 0.012). Cost-benefit analysis showed $646.60 savings (US dollars) per patient if programmable shunts were used, because the cost of shunt revision is a lot higher than the cost of the shunt. The rate of shunt revision is lower in patients with programmable devices, and these are therefore more cost-effective. In addition, the shunt adjustments made for patients with programmable devices also resulted in better neurological outcomes.
Momin, Eric N; Recinos, Pablo F; Coon, Alexander L; Rigamonti, Daniele
2010-06-01
Ventriculoatrial (VA) shunting is commonly used to treat hydrocephalus when ventriculoperitoneal shunting has failed. Placement of a VA shunt in patients with narrowing or occlusion of the central veins presents considerable difficulty because few imaging modalities exist to safely and reliably insert a guidewire or atrial catheter past the occlusion. We report the use of intraoperative venography to guide the placement of the distal portion of a VA shunt in a patient with a valve blocking the left brachiocephalic vein. A 42-year-old man with pseudotumor cerebri and a left ventriculoperitoneal shunt presented with severe headaches. He was diagnosed with partial distal shunt obstruction. Because of a history of failed attempts at ventriculoperitoneal shunting, conversion to a VA shunt via the left internal jugular vein was planned. Surgery was performed by using the standard technique until resistance was encountered when inserting a guidewire into the internal jugular vein. Intraoperative venography of the central veins was performed, which showed a large valve blocking progression of the guidewire in the left brachiocephalic vein. Using fluoroscopic guidance, a 0.035-inch guidewire was successfully directed through the vein past the obstruction and exchanged for a peel-away introducer. The distal shunt catheter was then inserted, and the correct position in the atrium was confirmed fluoroscopically. When obstruction of the central veins is found during a VA shunting procedure, intraoperative venography is a useful method to aid in the placement of the atrial catheter through the central veins.
Yamagami, Takuji; Yoshimatsu, Rika; Matsumoto, Tomohiro; Terayama, Koshi; Nishiumra, Akira; Maeda, Yousuke; Nishimura, Tsunehiko
2007-11-01
The authors report the case of a 6-year-old boy with a congenital extrahepatic portosystemic venous shunt. He had hyperammonemia. The shunt was 18 mm in diameter and located between the inferior mesenteric vein and the left internal iliac vein. The flow in the shunt was very rapid. After decreasing blood flow by inflating a balloon catheter inserted into the left internal iliac vein from the femoral vein, a microcatheter was coaxially advanced to the shunt to embolize the shunt. Embolization was successfully performed with interlocking detachable coils and microcoils without any complication. This patient's hyperammonemia resolved soon after the procedure.
NASA Astrophysics Data System (ADS)
Lenka, Manas K.; Sharma, Amit; Sharma, Jaibir; DasGupta, Amitava
2012-10-01
This paper describes the design and simulation of RF MEMS SPST shunt and SPDT shunt-shunt switches with modified coplanar waveguide (CPW) configuration for X-band and Ku-band applications exhibiting high isolation and low insertion loss. By modifying the basic CPW structure for a six-strip membrane having length 720 μm, the resonant frequency can be reduced from 33.5 GHz to 13.5 GHz with isolation as high as -30 dB(-63 dB at resonant frequency) in Ku-band. Similar results are also found in case SPST and SPDT switches with other membrane types.
Pleurovenous shunt for treating refractory benign pleural effusion.
Bayram, Ahmet Sami; Köprücüoğlu, Mustafa; Aygün, Mert; Gebitekin, Cengiz
2008-05-01
We report the case of a 63-year-old female with hepatic cirrhosis due to chronic hepatitis C, successfully treated for refractory nonmalignant hepatic hydrothorax by using a long-term pleurovenous shunt (PVS). After failure of conventional treatment by mechanical pleurodesis, a PVS was inserted to drain the pleural fluid into the right subclavian vein. After 8 months of follow-up, the effusion is well controlled, and the shunt remains patent.
Management of Hydrocephalus with Ventriculoperitoneal Shunts: Review of 109 Cases of Children.
Dakurah, Thomas K; Adams, Fuseini; Iddrissu, Mutawakilu; Wepeba, George Kojo; Akoto, Harry; Bankah, Patrick; Ametefe, Mawuli; Kasu, Philip W
2016-12-01
Treatment of hydrocephalus by shunting procedure is associated with variable outcomes, depending on the setting. Results from some published series in sub-Saharan Africa are not so good and various reasons have been given. This study presents preliminary findings of 109 cases of shunted hydrocephalus in children in a 3-year period. The main aim of the study was to evaluate the complications of the procedure in a tertiary-care center. It also seeks to identify ways of reducing such complications where appropriate in subsequent shunt placement procedures. A single-institutional retrospective study was conducted by reviewing 124 patients who had ventriculoperitoneal shunting including revisions, and subgroup analysis was performed in 109 patients younger than 18 years classified as children who had first-time shunt placement between January 2011 and December 2013. Data analysis was performed using Microsoft Excel and SPSS (version 20.0). The mean age at shunt insertion of the subgroup was 5.35 years ± 1.264 standard deviations. Shunt-related complications were identified in 37 of the patients (33.9%). Infections were the most common form of complication, occurring in 16 patients (14.6%). The overall mortality of the 109 patients was 4.59%. The most common indications for shunt insertions were tumoral and congenital lesions, which may offer us benefit with the use of endoscopic third ventriculostomy. Comprehensive follow-up of these patients may give a better picture of the magnitude of the problem; hence the need for properly designed prospective studies to improve the current outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.
Piatt, Joseph H; Freibott, Christina E
2014-07-01
OBJECT.: The Revision Quotient (RQ) has been defined as the ratio of the number of CSF shunt revisions to the number of new shunt insertions for a particular neurosurgical practice in a unit of time. The RQ has been proposed as a quality measure in the treatment of childhood hydrocephalus. The authors examined the construct validity of the RQ and explored the feasibility of risk stratification under this metric. The Kids' Inpatient Database for 1997, 2000, 2003, 2006, and 2009 was queried for admissions with diagnostic codes for hydrocephalus and procedural codes for CSF shunt insertion or revision. Revision quotients were calculated for hospitals that performed 12 or more shunt insertions annually. The univariate associations of hospital RQs with a variety of institutional descriptors were analyzed, and a generalized linear model of the RQ was constructed. There were 12,244 admissions (34%) during which new shunts were inserted, and there were 23,349 admissions (66%) for shunt revision. Three hundred thirty-four annual RQs were calculated for 152 different hospitals. Analysis of variance in hospital RQs over the 5 years of study data supports the construct validity of the metric. The following factors were incorporated into a generalized linear model that accounted for 41% of the variance of the measured RQs: degree of pediatric specialization, proportion of initial case mix in the infant age group, and proportion with neoplastic hydrocephalus. The RQ has construct validity. Risk adjustment is feasible, but the risk factors that were identified relate predominantly to patterns of patient flow through the health care system. Possible advantages of an alternative metric, the Surgical Activity Ratio, are discussed.
Germanò, Antonino; Caruso, Gerardo; Caffo, Mariella; Baldari, Sergio; Calisto, Amedeo; Meli, Francesco; Tomasello, Francesco
2003-03-01
This retrospective case series examines 7 infants with large supratentorial arachnoid cysts who underwent cyst-peritoneal shunting and insertion of a Hakim programmable valve. Comparing pre- and postoperative clinical data, neuroradiological and regional cerebral blood flow (rCBF) findings we evaluated the efficacy of the surgical procedure. Infants, ranging in age from 1 to 55 days (mean age 29.5 days), were assessed pre- and postoperatively by neurological examination, developmental profile and neuroimaging. Post procedure, all patients showed a significant reduction in the cyst/brain ratio on neuroimaging (p<0.001), 6 had a normal developmental profile (p<0.001) and 5 cases showed a significant amelioration of clinical symptoms and neurological signs. Two patients underwent preoperative SPECT scans, which showed hypoperfusion in the area surrounding the cyst; this decreased rCBF also improved post shunting. Large supratentorial arachnoid cysts in infants can be successfully treated with cyst-peritoneal shunting and insertion of a Hakim programmable valve. This is the first study specifically aimed at evaluating the long-term results of these conditions.
Ovarian hyperstimulation syndrome leading to ventriculoperitoneal shunt malfunction: Case report.
Azriel, Amit; Fleming, Benjamin; Dior, Uri P; Moscovici, Samuel; Sufaro, Yuval; Awad, Mohammed; Drummond, Kate
2018-06-01
Ventriculoperitoneal shunt (VPS) insertion is a common neurosurgical procedure for hydrocephalus. Unfortunately, VPS malfunction is not uncommon, with an estimated cumulative rate of 32% at 5 years. As flow through the shunt is influenced by the pressure gradient between the ventricles and the peritoneal cavity, malfunction may be caused by elevated intra-abdominal pressure. We present a rare patient with ascites following ovarian hyperstimulation syndrome (OHSS) leading to shunt malfunction. OHSS is a potentially life-threatening complication of controlled ovarian stimulation caused by the administration of exogenous gonadotropins. In this patient clinical and radiological resolution of shunt dysfunction were achieved following peritoneocentesis. To our knowledge this is the first described case of OHSS leading to shunt malfunction, emphasizing the importance of awareness, early recognition and proper management of abdominal etiologies of VPS malfunction. Copyright © 2018 Elsevier Ltd. All rights reserved.
Internal carotid artery rupture caused by carotid shunt insertion.
Illuminati, Giulio; Caliò, Francesco G; Pizzardi, Giulia; Vietri, Francesco
2015-01-01
Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Failed Ventriculoperitoneal Shunt: Is Retrograde Ventriculosinus Shunt a Reliable Option?
Oliveira, Matheus Fernandes de; Teixeira, Manoel Jacobsen; Reis, Rodolfo Casimiro; Petitto, Carlo Emanuel; Gomes Pinto, Fernando Campos
2016-08-01
Currently, the treatment of hydrocephalus is mainly carried out through a ventriculoperitoneal shunt (VPS) insertion. However, in some cases, there may be surgical revisions and requirement of an alternative distal site for shunting. There are several described distal sites, and secondary options after VPS include ventriculopleural and ventriculoatrial shunt, which have technical difficulties and harmful complications. In this preliminary report we describe our initial experience with retrograde ventriculosinus shunt (RVSS) after failed VPS. In 3 consecutive cases we applied RVSS to treat hydrocephalus in shunt-dependent patients who had previously undergone VPS revision and in which peritoneal space was full of adhesions and fibrosis. RVSS was performed as described by Shafei et al., with some modifications to each case. All 3 patients kept the same clinical profile after RVSS, with no perioperative or postoperative complications. However, revision surgery was performed in the first operative day in 1 out of 3 patients, in which the catheter was not positioned in the superior sagittal sinus. We propose that in cases where VPS is not feasible, RVSS may be a safe and applicable second option. Nevertheless, the long-term follow-up of patients and further learning curve must bring stronger evidence. Copyright © 2016 Elsevier Inc. All rights reserved.
Pseudomyopia in a patient with blocked ventriculo-peritoneal shunt--a case report.
Voon, L W; Goh, K Y; Lim, T H; Tan, K K; Yong, V S
1997-03-01
Accommodative spasm usually encompasses a classical triad of pseudomyopia, esodeviation and pupillary constriction. Accommodative spasm is most often psychogenic in nature; however, it may be associated with other organic diseases of which a rare cause is that of intracranial catheter complications. We report a case of dorsal midbrain syndrome with pseudomyopia in a patient with a blocked ventriculo-peritoneal shunt inserted for aqueductal stenosis. Clinical presentation was unusual in this patient as pseudomyopia occurred with exodeviation and without pupillary constriction.
Elgamal, E A
2010-04-01
The effectiveness of continuous intracranial pressure (ICP) monitoring in the adaptation period, after endoscopic third ventriculostomy (ETV), and removal of the failed shunt in the management of CSF shunt failure is assessed. Nine patients with active hydrocephalus presenting with CSF shunt obstruction or infection were managed by ETV, removal of the shunt and insertion of an external ventricular drain (EVD) containing an ICP sensor for the purpose of postoperative monitoring of the ICP, and intermittent drainage of CSF. Patient ages ranged from 8 months to 24 years, and six of them were females. Hydrocephalus was obstructive in seven patients, and multiloculated in two. Six patients had an ventriculoperitoneal shunt (VPS), one with a bilateral VPS, one patient had a ventriculoatrial shunt, and one had a VPS and cystoperitoneal shunt (CPS). Shunt failure was caused by obstruction in six patients and infection in three. The post-operative ICP monitoring period ranged from 1-7 days. Intracranial hypertension was persistent in the first day after ETV in 3 patients, and up to 110 mL of CSF were drained to improve its symptoms. ETV was successful in six patients and 3 had permanent VPS. Post-operative continuous ICP monitoring and EVD insertion were very useful in the treatment of CSF shunt failure with ETV. This procedure allowed intermittent CSF drainage, relieving symptoms of elevated ICP, and provided accurate assessment of the success of the ETV and patency of the stoma in the early postoperative days by CT ventriculography and can also be used to install antibiotics in cases of infection.
Playing a brass instrument after total laryngectomy: a case report.
Cavalot, Andrea Luigi; Schindler, Antonio; Juliani, Elsa; Schindler, Oskar; Cortesina, Giorgio
2009-08-01
A brass instrument is a musical instrument in which the tone is produced by vibration of the lips as the player blows into a tubular resonator. The case of a professional brass player who continued his activity after total laryngectomy, with insertion of a voice prosthesis in a tracheoesophageal shunt, is reported. A videoendoscopic and videofluoroscopic study of the patient during brass playing was conducted. A nonvibrating, open neoglottis during brass playing was found on videoendoscopy. Videofluorography revealed an enlarged hypopharynx, a thick neoglottis while playing at lower tone; at higher pitch the tongue base was retracted, the neoglottis was thin and stretched, and the subneoglottic area was extremely enlarged. The case reported shows that the insertion of a voice prosthesis in a tracheoesophageal shunt seems to create a regulating airflow system sufficiently advanced to play a brass instrument, further reducing the disability of laryngeal speakers. Copyright 2009 Wiley Periodicals, Inc.
Big heads in Port Moresby General Hospital: an audit of hydrocephalus cases seen from 2003 to 2004.
Kaptigau, W Matui; Ke, Liu; Rosenfeld, J V
2007-01-01
Hydrocephalus is a common neurosurgical problem in Port Moresby General Hospital (PMGH) contributing to 27 (24%) of the 114 neurosurgical operations done in 2003 and 2004. During the same period it was responsible for 25% of the cases seen in the neurosurgery clinic. To prospectively audit and follow up hydrocephalus cases in PMGH over 2 years from January 2003 to December 2004 and ascertain the causes and the outcome of treatment. All cases of hydrocephalus seen in 2003 and 2004 were categorized according to cause. The associated findings on ultrasound scan or CT (computed tomography) scan when available were noted. The subsequent progress was documented with and without treatment for at least 6 months. 61 cases of hydrocephalus were seen for surgical opinion. The age ranged from 4 weeks to 56 years. The commonest age group affected was in the first year of life (61% of cases). There were 34 cases (56%) of congenital hydrocephalus followed by 19 (31%) post meningitis and 8 (13%) due to tumour. There was only one case of myelomeningocele with concomitant hydrocephalus. Ventriculoperitoneal (VP) shunts were inserted in 24 cases. 3 shunts were bypasses from the posterior horn to the cisterna magna, making a total of 27 shunt operations. 9 shunts were performed for post-meningitic hydrocephalus, 15 for congenital stenosis and 3 for a posterior fossa tumour. 24 out of the 27 shunt operations were in children aged <9 months. Post-VP-shunt infection of 2 cases reported within 6 weeks of operation gave an infection rate of 7%. There was cerebrospinal fluid (CSF) leak in 2 cases with Pundez-type shunts. There were 2 shunt blocks needing revision. Shunt operations can be done in PMGH with good outcomes. The decision-making about surgery can be made on the basis of the enlarging head and the ultrasound findings.
Nørgaard, L N; Søgaard, K; Jensen, L N; Ekelund, C; Kahrs, B H; Tabor, A; Sundberg, K
2018-04-27
Pleural effusion is the most common fluid-accumulation in the fetus with a prevalence of 1:15.000-24.000 pregnancies. 1 The clinical picture is highly variable ranging from spontaneous resolution to lung hypoplasia, hydrops and death. 1 Treatment options include thoracocentesis, thoraco-amniotic shunting and pleurodesis using OK-432. 2 The conventional thoraco-amniotic shunts are applied using a 13-16G trochar. 3,4 Somatex® Intrauterine Shunt (IUS) was launched in 2014 and consists of a self-expanding nitinol wire mesh with an inner silicone coating to be inserted through an 18G/1.2 mm needle. This article is protected by copyright. All rights reserved.
Habuka, Masato; Ito, Toru; Yoshizawa, Yuta; Matsuo, Koji; Murakami, Shuichi; Kondo, Daisuke; Kanazawa, Hiroshi; Narita, Ichiei
2018-03-23
Refractory pleural effusion can be a life-threatening complication in patients receiving maintenance hemodialysis. We report successful treatment of refractory pleural effusion using a Denver® pleuroperitoneal shunt in one such patient. A 54-year-old Japanese man, who had previously undergone left nephrectomy, was admitted urgently to our department because of a high C-reactive protein (CRP) level, right pleural effusion, and right renal abscess. Because antibiotics proved ineffective and his general state was deteriorating, he underwent emergency insertion of a thoracic drainage tube and nephrectomy, and hemodialysis was started. Although his general state improved slowly thereafter, the pleural effusion, which was unilateral and transudative, remained refractory and therefore he needed to be on oxygenation. To control the massive pleural effusion, a pleuroperitoneal shunt was inserted. Thereafter, his respiratory condition became stable without oxygenation and he was discharged. His general condition has since been well. Although pleural effusion is a common complication of maintenance hemodialysis, few reports have documented the use of pleuroperitoneal shunt to control refractory pleural effusion. Pleuroperitoneal shunt has been advocated as an effective and low-morbidity treatment for refractory pleural effusion, and its use for some patients with recurrent pleural effusion has also been reported, without any severe complications. In the present case, pleuroperitoneal shunt improved the patient's quality of life sufficiently to allow him to be discharged home without oxygenation. Pleuroperitoneal shunt should be considered a useful treatment option for hemodialysis patients with refractory pleural effusion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoshiai, Sodai, E-mail: hoshiai@sb4.so-net.ne.jp; Mori, Kensaku; Ishiguro, Toshitaka
Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolizationmore » without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.« less
Bateman, G A
2003-02-01
Superficial cortical venous compression secondary to alterations in craniospinal compliance is implicated in the pathogenesis of normal pressure hydrocephalus (NPH). A reduction in the pulsation in the outflow of the cortical veins would be expected to occur following compression of these veins and this has been shown in NPH. If cortical vein compression is a causative factor in NPH, it would be expected that cortical vein compliance as measured by pulsatility would be significantly altered by a curative procedure i.e. shunt tube insertion. My purpose is to compare the blood flow pulsatility characteristics in a group of patients with NPH before and after shunt tube insertion. I initially studied 18 subjects without pathology with MRI flow quantification studies of the cerebral arteries and veins to define the range of normality. The main study involved 18 patients with idiopathic dementia and mild leukoaraiosis who served as controls and seven patients with NPH studied before and after shunt insertion. Arterial, superior sagittal and straight sinus pulsatility was not significantly different between the patients with idiopathic dementia and those NPH patients before or after shunting. Cortical vein pulsatility before shunting in the patients with NPH was 43% lower than in those with idiopathic dementia ( P=0.006). Following shunting, cortical vein pulsatility increased by 186% ( P=0.007). There is thus reduced compliance in cortical veins in NPH which is significantly increased in patients who respond to insertion of a shunt tube. These findings suggest that reversible elevation in cortical vein pressure and reversal of the normal absorption pathway for cerebrospinal fluid may be behind the pathophysiology of NPH.
Refractory priapism associated with ingestion of yohimbe extract.
Myers, Amy; Barrueto, Fermin
2009-12-01
Extracts of the bark of the central African tree Pausinystalia yohimbe contain yohimbine, an indole alkaloid, which is used to treat erectile dysfunction. The reported side effects of over-the-counter preparations of yohimbine include gastrointestinal upset, anxiety, increased blood pressure, headache, agitation, rash, tachycardia, and frequent urination. In this report, we describe a severe case of intractable priapism associated with the ingestion of yohimbe extract. Management required insertion of a proximal cavernosal spongiosum shunt (Quackles shunt) in the operating room.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Hakim, Ramsey, E-mail: ralhakim@mednet.ucla.edu; Patel, Komal, E-mail: kdpatel@mednet.ucla.edu; Moriarty, John M., E-mail: jmoriarty@mednet.ucla.edu
2015-06-15
This case reports describes a 39-year-old female with a history of surgically repaired hypoplastic left heart syndrome who presented with a left peripherally inserted central catheter (PICC) with associated large volume subclavian and brachiocephalic vein thrombus. Due to the presence of a right-to-left shunt via a fenestrated Fontan, there was clinical concern for a paradoxical embolism during removal of the PICC. The AngioVac aspiration system was successfully utilized to aspirate thromboemboli from the level of the proximal Glenn shunt during manipulation and removal of the PICC. This is the first reported case to demonstrate the safe and effective use ofmore » the AngioVac aspiration system for protection of paradoxical emboli through a cardiac right-to-left shunt during a procedure at high risk for thromboembolism.« less
Al-Hakim, Ramsey; Patel, Komal; Moriarty, John M
2015-06-01
This case reports describes a 39-year-old female with a history of surgically repaired hypoplastic left heart syndrome who presented with a left peripherally inserted central catheter (PICC) with associated large volume subclavian and brachiocephalic vein thrombus. Due to the presence of a right-to-left shunt via a fenestrated Fontan, there was clinical concern for a paradoxical embolism during removal of the PICC. The AngioVac aspiration system was successfully utilized to aspirate thromboemboli from the level of the proximal Glenn shunt during manipulation and removal of the PICC. This is the first reported case to demonstrate the safe and effective use of the AngioVac aspiration system for protection of paradoxical emboli through a cardiac right-to-left shunt during a procedure at high risk for thromboembolism.
Reversible CSF cyst related to a functioning ventriculo-peritoneal shunt.
Vajramani, G V; Fugleholm, K
2005-11-01
Although the occurrence of CSF oedema and cyst has been described in presence of a blocked ventriculoperitoneal shunt, especially distal end block, its occurrence in presence of a well functioning shunt has not been described so far. We report a case where a 51-year old lady developed an insidious onset and gradually progressive CSF cyst without any clinical or radiological feature of shunt block over a period of about 2 years. The changes started about 6 months after a course of radiation therapy for an extensive residual supra and infratentorial meningioma. Following surgery, where the cyst was punctured and a new ventricular catheter was inserted, despite well functioning upper and lower end, the cyst gradually disappeared. We review the literature and hypothesize that the radiation-induced changes were responsible for initiation and progression of the cyst.
Use of the proGAV shunt valve in normal-pressure hydrocephalus.
Toma, Ahmed K; Tarnaris, Andrew; Kitchen, Neil D; Watkins, Laurence D
2011-06-01
Overdrainage is a common complication associated with shunt insertion in normal-pressure hydrocephalus (NPH) patients. Using adjustable valves with antigravity devices has been shown to reduce its incidence. The optimal starting setting of an adjustable shunt valve in NPH is debatable. To audit our single-center practice of setting adjustable valves. We performed a retrospective review of clinical records of all NPH patients treated in our unit between 2006 and 2009 by the insertion of shunts with a proGAV valve, recording demographic and clinical data, shunt complications, and revision rates. Radiological reports of postoperative follow-up computed tomography scans of the brain were reviewed for detected subdural hematomas. A proGAV adjustable valve was inserted in 50 probable NPH patients between July 2006 and November 2009. Mean ± SD age was 76 ± 7 years. Mean follow-up was 15 months. The initial shunt setting was 6 ± 3 cm H2O, and the final setting was 4.9 ± 1.9 cm H2O. Nineteen patients required 24 readjustment procedures (readjustment rate, 38%; readjustment number, 0.48 times per patient). One patient (2%) developed delayed bilateral subdural hematoma after readjustment of his shunt valve setting as an outpatient. Starting with a low opening pressure setting on a proGAV adjustable shunt valve does not increase the chances of overdrainage complications and reduces the need for repeated readjustments.
Decreased head circumference in shunt-treated compared with healthy children.
Nilsson, Daniel; Svensson, Johanna; Korkmaz, Betül A; Nelvig, Helena; Tisell, Magnus
2013-11-01
In this study, the authors' goal was to compare head circumference in hydrocephalic children during the first 4 years of ventriculoperitoneal (VP) shunt treatment with data on healthy children and to investigate predictors of skull growth in children with a VP shunt. Children from western Sweden treated for hydrocephalus with an initial VP shunt insertion performed between 2001 and 2006 who were younger than 12 months of age at the time of surgery were included. Children with major brain malformations, craniofacial syndromes, large cysts, and tumors were excluded. Head circumference, weight, and height at 9 defined ages up to 4 years were obtained and compared with data from a reference population of 3650 healthy children using the standard deviation score (SDS). Predictors (length, weight, etiology of hydrocephalus, valve type, number of revisions, valve setting, number of adjustments, and time of first surgery) for head circumference SDS and changes in head circumference SDS from shunt insertion at 1 year to last measurement were analyzed using bivariate and multiple linear regression analysis. Fifty children were included. The mean SDSs for head circumference in shunt-treated compared with healthy children were 1.95 ± 2.50 at shunt insertion (p < 0.001, n = 44), 0.38 ± 1.97 at 1 year (p = 0.27, n = 33), -0.96 ± 2.05 at 2 years (p = 0.046, n = 21), -1.39 ± 2.25 at 3 years (p = 0.026, n = 16), and 0.63 ± 3.34 at 4 years (p = 0.73, n = 4). Significant predictors for low head circumference SDS at 1 year of age were low weight (p = 0.002) and short height (p = 0.022) and at last measurement low weight (p < 0.0001), short height (p = 0.002), and 1-4 shunt revisions (p = 0.034). A significant predictor for change in head circumference SDS from shunt insertion to 1 year of age was the number of shunt valve revisions (p = 0.04) and at last measurement an etiology of intraventricular hemorrhage (p = 0.0058). Shunt-treated children have smaller head circumferences at 2 and 3 years of age than healthy children. Low weight, short height, etiology of intraventricular hemorrhage, and frequent shunt valve revisions are predictors for decreased head circumference. Prospective, randomized studies comparing skull growth using fixed and adjustable pressure-regulated shunt valves and flow-regulated valves are needed.
Yadgarov, Arkadiy; Liu, Dan; Crane, Elliot S; Khouri, Albert S
2017-01-01
To describe postoperative surgical success of either Ahmed or Baerveldt tube shunt implantation for eyes with medically uncontrolled traumatic glaucoma. A review was carried out to identify patients with traumatic glaucoma that required tube shunt implantation between 2009 and 2015 at Rutgers University in Newark, New Jersey, USA. Seventeen eyes from 17 patients met inclusion criteria, including at least 3-month postoperative follow-up. The main outcome measure was surgical success at 1-year follow-up after tube implantation. Mean preoperative intraocular pressure (IOP) was 34.1 ± 8.2 mm Hg on 3.1 ± 1.6 ocular hypotensive medications. Nine eyes (53%) sustained closed globe injury. Ten eyes (59%) received an Ahmed valve shunt and seven eyes (41%) received a Baerveldt tube shunt. Surgical success rate at 1 year postoperatively was 83%. Compared to preoperative, the mean postoperative IOP was significantly lower (16.1 ± 3.5 mm Hg, p < 0.001) on significantly fewer ocular hypertensive medications (1.3 ± 1.6, p = 0.001) at a mean follow-up of 10 months. Mean IOP reduction at last follow-up was 49%. There were three cases of surgical failures: One case of hypotony, one case of tube extrusion with subsequent explan-tation, and one case requiring second tube insertion for IOP control. Implantation of an Ahmed or Baerveldt tube shunt provided successful control of IOP in patients with medically uncontrollable traumatic glaucoma. Yadgarov A, Liu D, Crane ES, Khouri AS. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma. J Curr Glaucoma Pract 2017;11(1):16-21.
Coulibaly, O; Dama, M; Diallo, O; Li, G; Sogoba, Y; Kanikomo, D
2016-04-01
Ventriculo-peritoneal shunt (VPS) continues to remain the main diverted method to drain the cerebrospinal fluid (CSF) from the ventricles to the peritoneal cavity. It has some complications that must be managed promptly to avoid any eventual fatal evolution. The association of delayed intracerebral and subdural hematomas after VPS insertion is a very rare complication and has, to our knowledge, never previously been reported in the literature. We report a very uncommon association of this entity occurring 11months after a shunt placement in a 13-year-old boy and discuss the likely pathogenesis, as well as the clinical and the radiological data. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Surgical management of hydrocephalus secondary to intraventricular hemorrhage in the preterm infant.
Christian, Eisha A; Melamed, Edward F; Peck, Edwin; Krieger, Mark D; McComb, J Gordon
2016-03-01
OBJECT Posthemorrhagic hydrocephalus (PHH) in the preterm infant remains a major neurological complication of prematurity. The authors first described insertion of a specially designed low-profile subcutaneous ventricular catheter reservoir for temporary management of hydrocephalus in 1983. This report presents the follow-up experience with the surgical management of PHH in this population and describes outcomes both in infants who were stable for permanent shunt insertion and those initially temporized with a ventricular reservoir (VR) prior to permanent ventriculoperitoneal (VP)/ventriculoatrial (VA) shunt placement. METHODS A retrospective review was undertaken of the medical records of all premature infants surgically treated for posthemorrhagic hydrocephalus (PHH) between 1997 and 2012 at Children's Hospital Los Angeles. RESULTS Over 14 years, 91 preterm infants with PHH were identified. Fifty neonates received temporizing measures via a VR that was serially tapped for varying time periods. For the remaining 41 premature infants, VP/VA shunt placement was the first procedure. Patients with a temporizing measure as their initial procedure had undergone CSF diversion significantly earlier in life than those who had permanent shunting as the initial procedure (29 vs 56 days after birth, p < 0.01). Of the infants with a VR as their initial procedure, 5/50 (10%) did not undergo subsequent VP/VA shunt placement. The number of shunt revisions and the rates of loculated hydrocephalus and shunt infection did not statistically differ between the 2 groups. CONCLUSIONS Patients with initial VR insertion as a temporizing measure received a CSF diversion procedure significantly earlier than those who received a permanent shunt as their initial procedure. Otherwise, the outcomes with regard to shunt revisions, loculated hydrocephalus, and shunt infection were not different for the 2 groups.
Fetal bladder catheterization in severe obstructive uropathy before the 24th week of pregnancy.
Szaflik, K; Kozarzewski, M; Adamczewski, D
1998-01-01
Fetal obstructive uropathy is simple to diagnose before the 24th week of life. Drainage of the pathologically enlarged fetal bladder avoids development of hydronephrosis and destruction of kidneys and, obviously, prevents development of secondary oligohydramnios and pulmonary hypoplasia. The aim of our study was to evaluate the usefulness of a fetal bladder shunt in cases of obstructive uropathy before the 24th week of gestation. From January 1997 we diagnosed 6 cases of fetal obstructive uropathy before the 24th week of gestation. In all cases oligohydramnios or ahydramnios was also observed. After evaluation of the renal function on the basis of fetal urine samples, we shunted 5 fetuses. After routine preparation of the operative field, a special puncture needle was inserted through the abdominal wall of mother and fetus into the fetal bladder. Through the needle a fetal bladder catheter was inserted between the fetal bladder and the amniotic sac. After shunt placement, fetal urine fills the amniotic sac and the fetal bladder is decompressed. After the procedure, the patients were hospitalized and serial sonographic examinations were performed to evaluate shunt function. Bladder size, presence and size of hydronephrosis, and volume of amniotic fluid were evaluated. The Rocket Medical catheters have an excellent 'shape memory'. All but 1 newborns had a good perinatal outcome. Mean Apgar score was 8 at 1 min, weight at delivery was between 1,700 and 3,100 g. No pulmonary hypoplasia was observed. All deliveries were after the 33rd week of gestation (range 33-38 weeks). The minimum drainage time was 11 weeks, maximum 18 weeks. In 2 cases premature delivery occurred because of premature rupture of the membranes. One newborn died of respiratory distress syndrome. Early bladder drainage (before the 24th week of gestation) enables delivery of newborns with a good perinatal outcome, without pulmonary hypoplasia. This method of therapy limits renal damage and allows time for normal development of the fetal lungs.
Rubin, Peter A D; Chang, Eli; Bernardino, Carlo Roberto; Hatton, Mark P; Dohlman, Claes H
2004-09-01
To describe a technique for inserting glaucoma shunts to the sinuses or the lacrimal sac as a means of lowering intraocular pressure in patients with refractory glaucoma associated with severe ocular surface disease. Nineteen patients with severe ocular surface disease necessitating a keratoprosthesis and with intractable glaucoma underwent placement of a modified Ahmed shunt to direct aqueous in the maxillary or ethmoid sinus or lacrimal sac. Intraocular pressure is presently well controlled without glaucoma medications in two thirds of patients. None of the patients had endophthalmitis. Established oculoplastic surgery techniques may be used to redirect aqueous to extraorbital locations and effectively lower intraocular pressure in patients with severe ocular surface disease and refractory glaucoma. This procedure has not been associated with endophthalmitis.
Erdogan, Hakan; Altun, Adnan; Kuruoglu, Enis; Kaya, Ahmet Hilmi; Dagcinar, Adnan
2017-09-26
Ventriculoatrial (VA) shunting is a well-described cerebrospinal fluid diversion method for the treatment of hydrocephalus. However, it may be very challenging in infants and little children because of atrial catheter placement difficulties. This study aimed to create an algorithm to solve problems faced during open surgical procedures based on the present authors' experience. We conducted a retrospective analysis on 18 infants and children who underwent VA shunt insertion at the Department of Neurosurgery, Ondokuz Mayıs University School of Medicine Hospital between 2005 and 2012. Complications, clinical outcomes, revisions, and solutions for overcoming distal catheter placement difficulties were evaluated. Twenty-six VA shunt operations were performed in 18 patients. Six patients required eight VA shunt revisions. VA shunting was primarily performed from the internal jugular, facial, cephalic, and subclavian veins to the right atrium. In revision procedures, the internal jugular, cephalic, and subclavian veins were used. VA shunting in infants and little children requires careful surgical techniques. Neurosurgeons should necessarily have an appropriate strategy for VA shunting considering the complications and revisions. Our results suggest open surgical solutions to overcome distal catheter placement difficulties in this age group.
Alkherayf, Fahad; Abou Al-Shaar, Hussam; Awad, Michael
2015-09-01
To evaluate the clinical outcomes and complications rate among idiopathic intracranial hypertension (IIH) patients who underwent lumboperitoneal (LP) shunt insertion with a programmable Strata valve. We retrospectively evaluated patients who underwent LP shunt with a programmable Strata valve insertion at the University of Ottawa Civic Hospital from November 2012 to June 2013. The demographic data, clinical symptoms, opening pressure, pre-operative and post-operative visual fields, neuroimaging, visual acuity, disc status, and complications were recorded and analyzed. Seven female patients with IIH underwent insertion of an LP shunt with a programmable Strata valve. The mean opening pressure was 35.8 cm H2O. The initial valve setting was 1.5, and four patients required post-operative valve pressure adjustment. All patients showed significant improvement in objective visual testing at follow-up as well as less frequent headaches. None of the patients developed intra- or post-operative complications. LP shunts with programmable Strata valve systems are a potential alternative to conventional LP and programmable ventriculoperitoneal shunt systems as well as optic nerve sheath fenestration, due to their potential in avoiding brain injury, lower failure and complication rates, lower intracranial hypotension incidence, and flexibility in adjusting valve pressure settings post-operatively evading under- and overdrainage complications. They should be considered for the management of IIH instead of early design LP systems and VP shunts. A randomized multi-center trial should be conducted to compare the efficacy of these surgical techniques. Copyright © 2015 Elsevier B.V. All rights reserved.
Shahi, Mohammad Vafaee; Noorbakhsh, Samileh; Zarrabi, Vida; Nourozi, Banafsheh; Tahernia, Leila
2018-01-01
Any mismatch between the production and absorption of CSF results in hydrocephalus. In most cases, the selected choice of treatment is the ventriculoperitoneal shunt insertion. Although, the surgery could have complications such as infection, shunt malfunction, subdural hematoma, seizure and Shunt immigration; so, the early and proper detection of these complications could result in better prognosis. The aim of this study was to evaluate and compare the efficacy of CT scan, CSF analysis and X-ray radiography in detection of shunt complications and problems in shunt placement and further follow-up in hospitalized children. The medical records of children in Rasul Akram hospital in Tehran were reviewed retrospectively in the last 10 years, from 2006 to 2016. All data were recorded in the prepared form including the age, sex, shunt complication, CT scan and CSF characteristics. The total number of 95 patients were interfered in this study including 56 males (58.9%) and 39 females (41.1%). The mean age at the onset of complications were 2.8±2.2 years-old. The shunt obstruction (60%) and infection (25.3%) were the most common complications. The CT scan was able to detect 36.5% of shunt complications. The CT scan had the sensitivity and specificity of 50 and 87%, respectively in detection of shunt obstruction. The all cases of brain hematoma and hemorrhage were revealed by CT scan. On the other hand, the CT scan had 20% of sensitivity and 60% of specificity in the detection of shunt infection. The CSF evaluation in shunt infection revealed 92% hypoglycemia, 87.5% pleocytosis, and 62.5% positive CSF culture. CSF had the sensitivity, specificity, positive predictive value and negative predictive value of 92, 82, 63 and 97%, respectively. The patient's symptoms and signs were helpful in obtaining higher test accuracy. The CT scan was not a good sensitive and specific study in the detection of shunt obstruction and infection, but it was very accurate in detection of hemorrhage and hematoma. On the other hand, CSF evaluation was a reliable test in shunt infection disclosure.
Glaucoma Mini-Shunt Implantation After Keratoplasty.
Ledesma-Gil, Jasbeth; García-Rodríguez, María de Los Ángeles; Gurria, Lulu U; Graue-Hernández, Enrique O; Navas, Alejandro
2017-04-01
To report the outcomes of patients who underwent miniature glaucoma shunt implantation after secondary glaucoma due to keratoplasty. Prospective study of consecutive clinical cases who underwent mini-glaucoma shunt implantation following keratoplasty. In brief, a fornix-based conjunctival flap was performed, approximately 50% thickness scleral flap. Mitomycin C 0.025% placed under Tenon's capsule. A 25-G needle created entry for mini-shunt. Ex-PRESS model P-50 was inserted. Scleral flap and conjunctiva were closed with 10-0 Nylon. STATA 8.0 and SPSS software were used for statistical analysis. Seventeen eyes of 17 patients with a mean age of 39.70 years (SD=18.33, range: 18 to 76). A total of 64.70% were male and 35.30% female. Eleven cases after penetrating keratoplasty, 3 cases after triple procedure, 2 after deep anterior lamellar keratoplasty, and 1 following endothelial keratoplasty. Most of the indications for keratoplasty were keratoconus in 9 cases (52.94%), 4 due to endothelial failure (23.52%), 3 cases of herpetic keratitis (17.64%), and 1 case of post-LASIK ectasia (5.88%). Mean preoperative intraocular pressure was 35.94 mm Hg with maximal medical therapy (SD=9.65, range: 18 to 55). Decreasing intraocular pressure to 12.76 mm Hg postoperatively (SD=2.51, range 10 to 18) (P=0.001). Mean follow-up after mini-glaucoma shunt implantation was 23.76 months (SD=8.73, range: 10 to 35 mo). Preoperative mean uncorrected distance visual acuity (UDVA) was 1.31±0.63 (20/408 Snellen) and postoperative mean UDVA was 0.85±0.40 (20/141 Snellen) (P=0.001). Preoperative mean corrected distance visual acuity (CDVA) was 0.83±0.76 (20/135 Snellen) and postoperative mean CDVA was 0.56±0.44 (20/72 Snellen) (P=0.032). Ex-PRESS miniature glaucoma shunt could be an alternative treatment in postkeratoplasty glaucoma resistant to medical treatment. This technique may be helpful, in trying to avoid corneal damage produced by conventional glaucoma procedures.
Aqueous shunts in glaucoma: a report by the American Academy of Ophthalmology.
Minckler, Don S; Francis, Brian A; Hodapp, Elizabeth A; Jampel, Henry D; Lin, Shan C; Samples, John R; Smith, Scott D; Singh, Kuldev
2008-06-01
To provide an evidence-based summary of commercially available aqueous shunts currently used in substantial numbers (Ahmed [New World Medical, Inc., Rancho Cucamonga, CA], Baerveldt [Advanced Medical Optics, Inc., Santa Ana, CA], Krupin [Eagle Vision, Inc, Memphis, TN], Molteno [Molteno Ophthalmic Ltd., Dunedin, New Zealand]) to control intraocular pressure (IOP) in various glaucomas. Seventeen previously published randomized trials, 1 prospective nonrandomized comparative trial, 1 retrospective case-control study, 2 comprehensive literature reviews, and published English language, noncomparative case series and case reports were reviewed and graded for methodologic quality. Aqueous shunts are used primarily after failure of medical, laser, and conventional filtering surgery to treat glaucoma and have been successful in controlling IOP in a variety of glaucomas. The principal long-term complication of anterior chamber tubes is corneal endothelial failure. The most shunt-specific delayed complication is erosion of the tube through overlying conjunctiva. There is a low incidence of this occurring with all shunts currently available, and it occurs most frequently within a few millimeters of the corneoscleral junction after anterior chamber insertion. Erosion of the equatorial plate through the conjunctival surface occurs less frequently. Clinical failure of the various devices over time occurs at a rate of approximately 10% per year, which is approximately the same as the failure rate for trabeculectomy. Based on level I evidence, aqueous shunts seem to have benefits (IOP control, duration of benefit) comparable with those of trabeculectomy in the management of complex glaucomas (phakic or pseudophakic eyes after prior failed trabeculectomies). Level I evidence indicates that there are no advantages to the adjunctive use of antifibrotic agents or systemic corticosteroids with currently available shunts. Too few high-quality direct comparisons of various available shunts have been published to assess the relative efficacy or complication rates of specific devices beyond the implication that larger-surface-area explants provide more enduring and better IOP control. Long-term follow-up and comparative studies are encouraged.
Syringo-Subarachnoid-Peritoneal Shunt Using T-Tube for Treatment of Post-Traumatic Syringomyelia
Kim, Seon-Hwan; Youm, Jin-Young; Kwon, Hyon-Jo
2012-01-01
Various surgical procedures for the treatment of post-traumatic syringomyelia have been introduced recently, but most surgical strategies have been unreliable. We introduce the concept and technique of a new shunting procedure, syringo-subarachnoid-peritoneal shunt. A 54-year-old patient presented to our hospital with a progressive impairment of motion and position sense on the right side. Sixteen years before this admission, he had been treated by decompressive laminectomy for a burst fracture of L1. On his recent admission, magnetic resonance (MR) imaging studies of the whole spine revealed the presence of a huge syrinx extending from the medulla to the L1 vertebral level. We performed a syringo-subarachnoid-peritoneal shunt, including insertion of a T-tube into the syrinx, subarachnoid space and peritoneal cavity. Clinical manifestations and radiological findings improved after the operation. The syringo-subarachnoid-peritoneal shunt has several advantages. First, fluid can communicate freely between the syrinx, the subarachnoid space, and the peritoneal cavity. Secondly, we can prevent shunt catheter from migrating because dural anchoring of the T-tube is easy. Finally, we can perform shunt revision easily, because only one arm of the T-tube is inserted into the intraspinal syringx cavity. We think that this procedure is the most beneficial method among the various shunting procedures. PMID:22993681
Persistent hydrocephalus due to postural activation of a ventricular shunt anti-gravity device.
Craven, Claudia L; Toma, Ahmed K; Watkins, Laurence D
2017-03-01
The ever present need to balance over drainage with under drainage in hydrocephalus has required innovations including adjustable valves with antigravity devices. These are activated in the vertical position to prevent siphoning. We describe a group of bedridden patients who presented with unexplained under drainage caused by activation of antigravity shunt components produced by peculiar head/body position. Retrospective single centre case series of hydrocephalus patients, treated with ventriculo-peritoneal (VP) shunt insertion between April 2014 - February 2016. These patients presented with clinical and radiological under drainage syndrome. Medical notes were reviewed for clinical picture and outcome. Radiological studies were reviewed assessing shunt placement and ventricular size. Seven patients presented with clinical and radiological under drainage syndrome. A consistent posturing of long term hyper-flexion of the neck whilst lying supine was observed. All patients had similar shunt construct (adjustable Miethke ProGAV valve and shunt assistant anti-gravity component). In each of those patients a hypothesis was formulated that neck flexion was activating the shunt assistance anti-gravity component in supine position. Five patients underwent shunt revision surgery removing the shunt assistant device from the cranium and adding an anti-gravity component to the shunt system at the chest. One had the shunt assistant completely removed and one patient was managed conservatively with mobilisation. All patients had clinical and radiological improvement. Antigravity shunt components implanted cranially in bedridden hydrocephalus patients will produce underdrainage due to head flexion induced anti-gravity device activation. In these patients, anti-gravity devices should be placed at the chest. Alternatively, special nursing attention should be paid to head-trunk angle. Copyright © 2016 Elsevier Ltd. All rights reserved.
Our initial experience with ventriculo-epiplooic shunt in treatment of hydrocephalus in two centers.
Grigorean, Valentin Titus; Sandu, Aurelia Mihaela; Popescu, Mihai; Florian, Ioan Stefan; Lupascu, Cristian Dumitru; Ursulescu, Corina Lupascu
Hydrocephalus represents impairment in cerebrospinal fluid (CSF) dynamics. If the treatment of hydrocephalus is considered difficult, the repeated revisions of ventriculo-peritoneal (VP) shunts are even more challenging. The aim of this article is to evaluate the efficiency of ventriculo-epiplooic (VEp) shunt as a feasible alternative in hydrocephalic patients. A technical modification regarding the insertion of peritoneal catheter was imagined: midline laparotomy 8-10cm long was performed in order to open the peritoneal cavity; the great omentum was dissected between its two layers; we placed the distal end of the catheter between the two epiplooic layers; a fenestration of 4cm in diameter into the visceral layer was also performed. A retrospective study of medical records of 15 consecutive patients with hydrocephalus treated with VEp shunt is also presented. Between 2008 and 2014 we performed VEp shunt in 15 patients: 5 with congenital hydrocephalus, 8 with secondary hydrocephalus and 2 with normal pressure hydrocephalus. There were 7 men and 8 women. VEp shunt was performed in 13 patients with multiple distal shunt failures and in 2 patients, with history of abdominal surgery, as de novo extracranial drainage procedure. The outcome was favorable in all cases, with no significant postoperative complications. VEp shunt is a new, safe and efficient surgical technique for the treatment of hydrocephalus. VEp shunt is indicated in patients with history of recurrent distal shunt failures, and in patients with history of open abdominal surgery and high risk for developing abdominal complications. Copyright © 2017 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
Paulsen, A Henriette; Lundar, Tryggve; Lindegaard, Karl-Fredrik
2010-12-01
Shunting of CSF is one of the most commonly performed operations in the pediatric neurosurgeon's repertoire. The 1st decade after initial shunt insertion has been addressed in several previous reports. The goals of the authors' study, therefore, were to determine 20-year outcomes in young adults with childhood hydrocephalus and to assess their health-related quality of life (HRQOL). Patients younger than 15 years of age, in whom a first-time shunt insertion was performed for hydrocephalus in the calendar years 1985-1988, were included in a retrospective study on surgical morbidity, mortality rates, academic achievement, and/or work participation. Information concerning perceived health and functional status was assessed using the 36-Item Short Form Health Survey (SF-36) and Barthel Index, which were completed by patients still alive by September 1, 2009. Overall, 138 patients participated, no patient being lost to follow-up. For the 20-year period, the overall mortality rate was 21.7%. The mortality rate was not significantly higher in the 1st decade after initial shunt insertion than in the 2nd decade (p = 0.10). Ten percent of the patients surviving still live with their primary shunt in place, whereas 81% required at least one revision, and among these individual the mean number of revisions was 4.2 (median 3, range 0-26). There was a significantly higher revision rate during the 1st decade after initial shunt insertion compared with the 2nd decade (p = 0.027). The majority of patients live lives comparable with those of their peers. At follow-up, 56% were employed in open-market jobs or were still students, 23% had sheltered employment, and 21% were unemployed. The HRQOL was slightly lower in the hydrocephalic cohort than in the normative population. A significant difference was found in 2 of 8 SF-36 domains-Physical Functioning and General Health. During the 20-year follow-up period, 81% of the patients required at least one revision of the CSF shunt. The mortality rate was high: 24 patients died in the 1st decade and 6 died in the 2nd decade after implantation of the initial shunt. In total, 4 deaths (2.9%) were due to shunt failure. Shunt placement to treat childhood hydrocephalus has a substantial effect on social functioning in later life, although perceived health was positively found to be better than expected in young adults with hydrocephalus.
2014-01-01
Background Insertion of a ventriculoperitoneal shunt (VPS) for the treatment of hydrocephalus is one of the most common neurosurgical procedures in the UK, but failures caused by infection occur in approximately 8% of primary cases. VPS infection is associated with considerable morbidity and mortality and its management results in substantial cost to the health service. Antibiotic-impregnated (rifampicin and clindamycin) and silver-impregnated VPS have been developed to reduce infection rates. Whilst there is some evidence showing that such devices may lead to a reduction in VPS infection, there are no randomised controlled trials (RCTs) to support their routine use. Methods/design Overall, 1,200 patients will be recruited from 17 regional neurosurgical units in the UK and Ireland. Patients of any age undergoing insertion of their first VPS are eligible. Patients with previous indwelling VPS, active and on-going cerebrospinal fluid (CSF) or peritoneal infection, multiloculated hydrocephalus requiring multiple VPS or neuroendoscopy, and ventriculoatrial or ventriculopleural shunt planned will be excluded. Patients will be randomised 1:1:1 to either standard silicone (comparator), antibiotic-impregnated, or silver-impregnated VPS. The primary outcome measure is time to VPS infection. Secondary outcome measures include time to VPS failure of any cause, reason for VPS failure (infection, mechanical failure, or patient failure), types of bacterial VPS infection (organism type and antibiotic resistance), and incremental cost per VPS failure averted. Discussion The British antibiotic and silver-impregnated catheters for ventriculoperitoneal shunts multi-centre randomised controlled trial (the BASICS trial) is the first multi-centre RCT designed to determine whether antibiotic or silver-impregnated VPS reduce early shunt infection compared to standard silicone VPS. The results of this study will be used to inform current neurosurgical practice and may potentially benefit patients undergoing shunt surgery in the future. Trial registration International Standard Randomised Controlled Trial Number: ISRCTN49474281. PMID:24383496
Bech, R A; Waldemar, G; Gjerris, F; Klinken, L; Juhler, M
1999-01-01
Normal Pressure Hydrocephalus (NPH) is a potentially treatable syndrome with abnormal cerebrospinal fluid dynamics. Meningeal fibrosis and/or obliteration of the subarachnoid space have been suggested as one of the patho-anatomical substrates. However, other types of adult onset dementia, predominantly Alzheimer's disease and Vascular Dementia, may mimic the clinical NPH characteristics. The purpose of the present study was to correlate cerebral parenchymal and leptomeningeal biopsy findings to the clinical outcome after CSF shunting in a prospective group of idiopathic NPH (INPH) patients. The study comprises 27 patients with INPH, diagnosed and shunted according to generally accepted clinical, imaging and hydrodynamic criteria. In all patients a frontal leptomeningeal and brain biopsy was obtained prior to the shunt insertion. Degenerative cerebral changes, most often Alzheimer (6 cases) or vascular changes (7 cases) were described in 14 out of 27 biopsies. Arachnoid fibrosis was found in 9 of the 18 biopsies containing arachnoid tissue. Overall, nine patients (33%) improved, of whom 6 presented Alzheimer or vascular changes in their biopsies. No correlation was found between clinical outcome and the presence or absence of degenerative cerebral changes and/or arachnoid fibrosis. However, a tendency towards higher improvement rates was noted in the subgroups presenting degenerative cerebral changes or arachnoid fibrosis. The results suggest that no constant morphological element exists in the syndrome of INPH. Various aetiologies may be involved in the pathogenesis and possibly in some cases co-existing: Patients may also improve by shunting despite the presence of degenerative cerebral parenchymal changes.
Ozisik, Pinar; Roth, Jonathan; Beni-Adani, Liana; Constantini, Shlomi
2011-11-01
This study evaluates the safety, efficacy, and indications for continuous lumbar drainage (CLD) in patients following endoscopic third ventriculostomy (ETV). We retrospectively reviewed the clinical data of 22 consecutive patients treated between 1996 and 2010 with CLD after ETV. The decision to insert a CLD was made in selected patients only. CLD was inserted in cases of high measured intracranial pressure (12 patients), clinical symptoms indicative of continuing hydrocephalus (2 patients), and "prophylactically" in 8 patients, based either on the clinical condition of patients before ETV or on technical difficulties during the ETV procedure, which seemed to increase the risk of ETV failure. CLD insertion took place either in the operating room immediately following the ETV procedure or under very specific conditions and with close patient monitoring in an ICU setting. Only four patients eventually required shunting, all within 1 month after ETV. Therefore, the overall ETV success rate was 81.8% (18/22 patients). Of the 14 patients suffering from measured or clinically observed continuing hydrocephalus, 12 (85%) ultimately recovered without the need for a permanent shunt. Without the CLD, some of these patients would probably have been declared "failures" and referred for a standard shunt. CLD provided a time window following ETV for the absorption system to recover and return to full functionality. Selective usage of CLD is a reasonable and safe method to gain time and possibly facilitates the recovery of absorption capacity following ETV. CLD should be considered before conceding a post-ETV patient as a failure.
Evaluation of Blalock-Taussig shunts in newborns: value of oblique MRI planes.
Kastler, B; Livolsi, A; Germain, P; Zöllner, G; Dietemann, J L
1991-01-01
Eight infants with systemic-pulmonary Blalock-Taussig shunts were evaluated by spin-echo ECG-gated MRI. Contrary to Echocardiography, MRI using coronal oblique projections successfully visualized all palliative shunts entirely in one single plane (including one carried out on a right aberrant subclavian artery). MRI allowed assessment of size, course and patency of the shunt, including pulmonary and subclavian insertion. The proximal portion of the pulmonary and subclavian arteries were also visualized. We conclude that MRI with axial scans completed by coronal oblique planes is a promising, non invasive method for imaging the anatomical features of Blalock-Taussig shunts.
Finite Ground Coplanar Waveguide Shunt MEMS Switches for Switched Line Phase Shifters
NASA Technical Reports Server (NTRS)
Ponchak, George E.; Simons, Rainee N.; Scardelletti, Maximillian; Varaljay, Nicholas C.
2000-01-01
Switches with low insertion loss and high isolation are required for switched line phase shifters and the transmit/receive switch at the front end of communication systems. A Finite Ground Coplanar (FGC) waveguide capacitive, shunt MEMS switch has been implemented on high resistivity Si. The switch has demonstrated an insertion loss of less than 0.3 dB and a return loss greater than 15 dB from 10 to 20, GHz. The switch design, fabrication, and characteristics are presented.
Wang, Guangming; Yu, Jinlu; Luan, Yongxin; Han, Yanwu; Fu, Shuanglin
2017-01-01
Ventriculoperitoneal shunts (VPS) are the primary treatment for hydrocephalus and are associated with a high risk of complications, specifically in patients who are obese or have abdominal adhesions or shunt revisions. The present study describes the use of a novel type of peritoneal catheter peritoneocentesis trocar insertion with the assistance of a one-port laparoscope. A total of 36 patients with hydrocephalus underwent this novel type of peritoneocentesis trocar-assisted VPS. The distal shunt catheter was placed into the right subdiaphragmatic space and the catheter was traversed through a single hole drilled through the liver falciform ligament. The duration of the laparoscopic surgery ranged from 6–18 min (mean 10.4±1.6 min). No shunt-related infections or catheter malfunctions or injuries to the intra-abdominal organs occurred. The total abdominal incision length was 1.0 cm (0.5+0.5 cm). No laparoscopy-related complications were observed during follow-up assessments. The novel approach used in the current study is very easy to perform, and this method may significantly reduce the risk of malfunction complications. The presented method also has the advantages of reduced trauma and a simpler surgery. The current study indicated that this simple, minimally invasive procedure was beneficial for patients with hydrocephalus, specifically in cases of patients with obesity, peritoneal adhesions or shunt revisions. PMID:29042927
Wang, Guangming; Yu, Jinlu; Luan, Yongxin; Han, Yanwu; Fu, Shuanglin
2017-10-01
Ventriculoperitoneal shunts (VPS) are the primary treatment for hydrocephalus and are associated with a high risk of complications, specifically in patients who are obese or have abdominal adhesions or shunt revisions. The present study describes the use of a novel type of peritoneal catheter peritoneocentesis trocar insertion with the assistance of a one-port laparoscope. A total of 36 patients with hydrocephalus underwent this novel type of peritoneocentesis trocar-assisted VPS. The distal shunt catheter was placed into the right subdiaphragmatic space and the catheter was traversed through a single hole drilled through the liver falciform ligament. The duration of the laparoscopic surgery ranged from 6-18 min (mean 10.4±1.6 min). No shunt-related infections or catheter malfunctions or injuries to the intra-abdominal organs occurred. The total abdominal incision length was 1.0 cm (0.5+0.5 cm). No laparoscopy-related complications were observed during follow-up assessments. The novel approach used in the current study is very easy to perform, and this method may significantly reduce the risk of malfunction complications. The presented method also has the advantages of reduced trauma and a simpler surgery. The current study indicated that this simple, minimally invasive procedure was beneficial for patients with hydrocephalus, specifically in cases of patients with obesity, peritoneal adhesions or shunt revisions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ha, Thuong G. Van, E-mail: tgvanha@radiology.bsd.uchicago.edu; Hodge, Justin; Funaki, Brian
2006-10-15
Purpose. To determine the safety and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) creation in patients with liver cirrhosis complicated by thrombosed portal vein. Methods. This study reviewed 15 cases of TIPS creation in 15 cirrhotic patients with portal vein thrombosis at our institution over an 8-year period. There were 2 women and 13 men with a mean age of 53 years. Indications were refractory ascites, variceal hemorrhage, and refractory pleural effusion. Clinical follow-up was performed in all patients. Results. The technical success rate was 75% (3/4) in patients with chronic portal vein thrombosis associated with cavernomatous transformation and 91%more » (10/11) in patients with acute thrombosis or partial thrombosis, giving an overall success rate of 87%. Complications included postprocedural encephalopathy and localized hematoma at the access site. In patients with successful shunt placement, the total follow-up time was 223 months. The 30-day mortality rate was 13%. Two patients underwent liver transplantation at 35 days and 7 months, respectively, after TIPS insertion. One patient had an occluded shunt at 4 months with an unsuccessful revision. The remaining patients had functioning shunts at follow-up. Conclusion. TIPS creation in thrombosed portal vein is possible and might be a treatment option in certain patients.« less
Datt, Vishnu; Tempe, D. K.; Lalwani, Parin; Aggarwal, Saket; Kumar, Pradeep; Diwakar, Anitha; Tomar, A. S.
2015-01-01
Perioperative management of a patient with Dandy–Walker malformation (DWM) with tetralogy of Fallot (TOF), patent ductus arteriosus, and pulmonary artery stenosis is a great challenge to the anesthesiologist. Anesthetic management in such patients can trigger tet spells that might rapidly increase intracranial pressure (ICP), conning and even death. The increase in ICP can precipitate tet spells and further brain hypoxia. To avoid an increase in ICP during TOF corrective surgery ventriculo-peritoneal (VP) shunt should be performed before cardiac surgery. We present the first case report of a 11-month-old male baby afflicted with DWM and TOF who underwent successful TOF total corrective surgery and fresh autologous pericardial pulmonary valve conduit implantation under cardiopulmonary bypass after 1 week of VP shunt insertion. PMID:26139758
Datt, Vishnu; Tempe, D K; Lalwani, Parin; Aggarwal, Saket; Kumar, Pradeep; Diwakar, Anitha; Tomar, A S
2015-01-01
Perioperative management of a patient with Dandy-Walker malformation (DWM) with tetralogy of Fallot (TOF), patent ductus arteriosus, and pulmonary artery stenosis is a great challenge to the anesthesiologist. Anesthetic management in such patients can trigger tet spells that might rapidly increase intracranial pressure (ICP), conning and even death. The increase in ICP can precipitate tet spells and further brain hypoxia. To avoid an increase in ICP during TOF corrective surgery ventriculo-peritoneal (VP) shunt should be performed before cardiac surgery. We present the first case report of a 11-month-old male baby afflicted with DWM and TOF who underwent successful TOF total corrective surgery and fresh autologous pericardial pulmonary valve conduit implantation under cardiopulmonary bypass after 1 week of VP shunt insertion.
Schreml, S; Gruendobler, B; Schreml, J; Bayer, M; Ladoyanni, E; Prantl, L; Eichelberg, G
2008-08-01
Neurocutaneous melanosis (NCM) is a rare congenital noninheritable phacomatosis characterized by large and/or numerous cutaneous congenital melanocytic naevi (CMN) in combination with melanocytic leptomeningeal tumours. Dandy-Walker malformation (DWM) consists of a cystic dilatation of the fourth ventricle communicating with the posterior fossa, and a high insertion of the tentorium and hypoplasia/aplasia of the cerebellar vermis (partially caused by Zic1(+/-)Zic 4(+/-) on 3q2). An association of NCM and DWM is very rare, with only 15 previously reported cases to our knowledge. We present an 8-year-old girl with multiple CMN and DWM. A ventriculoperitoneal shunt operation was performed when she was 1 day old. Her neurological symptoms to date comprise headaches, nausea and vomiting as a result of ventriculoperitoneal shunt dislocation at the age of 4 years. The diagnosis is provisional asymptomatic multiple CMN-type NCM in association with DWM.
Dandy-Walker complex and syringomyelia in an adult: case report and discussion.
Hammond, Christopher J; Chitnavis, Bhupal; Penny, Christopher C; Strong, Anthony J
2002-01-01
Syringomyelia in association with the Dandy-Walker complex is rare and only 17 cases have been reported, mostly as autopsy findings or incidental reports in series for other conditions. We present a further case report and discuss the possible pathogenetic mechanisms of syrinx formation in the presence of the Dandy-Walker complex. We emphasize the role of foramen magnum obstruction and alteration in cerebrospinal fluid flow dynamics in syrinx formation. The therapeutic importance of disimpaction of the foramen magnum is stressed. A 39-year-old man presented with headache. As a child, he had had cystoperitoneal and ventriculoperitoneal shunts inserted for hydrocephalus in association with the Dandy-Walker complex. On examination, the patient had limited upgaze but was otherwise normal. Magnetic resonance imaging revealed a large cervicothoracic syrinx and a Dandy-Walker cyst obstructing the foramen magnum. The cystoperitoneal shunt was revised. The patient's headaches resolved, and follow-up imaging demonstrated resolution of the syrinx and disimpaction of the foramen magnum. Disimpaction of the foramen magnum can resolve syringomyelia in patients with the Dandy-Walker complex. This can be achieved by a shunt procedure or by formal foramen magnum decompression. The rarity of the association between the Dandy-Walker complex and syringomyelia prevents firm conclusions from being made regarding the best management strategy for this condition.
Treatment options for Dandy-Walker malformation.
Mohanty, Aaron; Biswas, Arundhati; Satish, Satyanarayana; Praharaj, Shanti Shankar; Sastry, Kolluri V R
2006-11-01
The aim of this study was to assess the efficacy of various treatment options available for children with Dandy-Walker malformation (DWM) and to evaluate the role of endoscopic procedures in the treatment of this disorder. The authors conducted a retrospective review of 72 children who underwent surgical treatment for DWM during a 16-year period. All patients underwent computed tomography scanning, and 26 underwent magnetic resonance (MR) imaging. The initial surgical treatment included ventriculoperitoneal (VP) shunt placement in 21 patients, cystoperitoneal (CP) shunt placement in 24, and combined VP and CP shunt insertion in three. Twenty-one patients underwent endoscopic procedures (endoscopic third ventriculostomy [ETV] alone in 16 patients, ETV with aqueductal stent placement in three, and ETV with fenestration of the occluding membrane in two). Three patients underwent membrane excision via a posterior fossa craniectomy. In the 26 patients who had undergone preoperative MR imaging, aqueductal patency was noted in 23 and aqueductal obstruction in three. These three patients underwent placement of a stent from the third ventricle to the posterior fossa cyst in addition to the ETV procedure. During the follow-up period, 12 patients with a CP shunt and four with a VP shunt experienced shunt malfunctions that required revision. Four patients with a CP shunt also required placement of a VP shunt. In addition, five of the 21 ETVs failed, requiring VP shunt insertion. A reduction in ventricle size noted on postoperative images occurred more frequently in patients with a VP shunt, whereas a reduction in cyst size was more appreciable in patients with a CP shunt. Successful ETV resulted in a slight decrease in ventricle size and varying degrees of reduction in cyst size. Endoscopic procedures may be considered an acceptable alternative in children with DWM. The authors propose a treatment protocol based on preoperative MR imaging findings of associated aqueductal stenosis.
Santos, Marcelo Volpon; Garcia, Camila Araujo Bernardino; Jardini, Evelise Oliveira; Romeiro, Thais Helena; da Silva Lopes, Luiza; Machado, Hélio Rubens; de Oliveira, Ricardo Santos
2016-08-01
Hydrocephalus is a complex disease that affects cerebrospinal fluid (CSF) dynamics and is very common in children. To this date, CSF shunting is still the standard treatment for childhood hydrocephalus, but, nevertheless, the effects of such an operation on the developing brain are widely unknown. To help overcome this, experimental models of CSF shunts are surely very useful tools. The objective of this study was to describe a feasible and reliable technique of an adapted ventricular-subcutaneous shunt for the treatment of kaolin-induced hydrocephalus in young rats. We developed a ventricular-subcutaneous shunt (VSCS) technique which was used in 31 Wistar young rats with kaolin-induced hydrocephalus. Hydrocephalus was induced at 7 days of age, and shunt implantation was performed 7 days later. Our technique used a 0.7-mm gauge polypropylene catheter tunneled to a subcutaneous pocket created over the animal's back and inserted into the right lateral ventricle. All animals were sacrificed 14 days after shunt insertion. Twenty-four rats survived and remained well until the study was ended. No major complications were seen. Their weight gain went back to normal. They all underwent ambulatory behavioral testing prior and after VSCS, which showed improvement in their motor skills. We have also obtained magnetic resonance (MR) scans of 16 pups confirming reduction of ventricular size after shunting and indicating effective treatment. Histopathological analysis of brain samples before and after shunting showed reversion of ependymal and corpus callosum disruption, as well as fewer reactive astrocytes in shunted animals. An experimental CSF shunt technique was devised. Excessive CSF of hydrocephalic rats is diverted into the subcutaneous space where it can be resorbed. This technique has a low complication rate and is effective. It might be applied to various types of experimental studies involving induction and treatment of hydrocephalus.
Musara, A; Kalangu, K K N
2010-01-01
Hydranencephaly is a rare condition characterised by complete or near complete absence of the cerebral hemispheres within relatively normal sized meninges and skull, the resulting cavity being filled with cerebrospinal fluid. The following is a case report of a five month old hydranencephalic child with right upper motor facial nerve palsy who presented with signs of hydrocephalus who developed intractable hypothermia rapidly post ventriculo-peritoneal shunt insertion and demised. Her preoperative condition was associated with hypothermia.
Incarceration of umbilical hernia after radiological insertion of a Denver peritoneovenous shunt.
Ohta, Kengo; Shimohira, Masashi; Hashizume, Takuya; Kawai, Tatsuya; Kurosaka, Kenichiro; Suzuki, Kazushi; Watanabe, Kenichi; Shibamoto, Yuta
2013-03-01
We report a rare complication of incarceration of an umbilical hernia after Denver peritoneovenous shunt placement. A 50-year-old man presented with refractory ascites from liver cirrhosis. He also had an umbilical hernia. Because the ascites became uncontrollable, Denver peritoneovenous shunting was performed. The operation was successful and the ascites decreased. Ten days later, however, incarceration of the umbilical hernia occurred. A surgical repair was performed, but he died 2 days later. The cause of death was considered to be sepsis.
Hamilton, Roy; Patel, Sunil; Lee, Edward B; Jackson, Eric M; Lopinto, Joanna; Arnold, Steven E; Clark, Christopher M; Basil, Anuj; Shaw, Leslie M; Xie, Sharon X; Grady, M Sean; Trojanowski, John Q
2010-10-01
To determine the impact of cortical Alzheimer disease pathology on shunt responsiveness in individuals treated for idiopathic normal pressure hydrocephalus (iNPH), 37 patients clinically diagnosed with iNPH participated in a prospective study in which performance on neurologic, psychometric, and gait measures before and 4 months after shunting was correlated with amyloid β plaques, neuritic plaques, and neurofibrillary tangles observed in cortical biopsies obtained during shunt insertion. No complications resulted from biopsy acquisition. Moderate to severe pathology was associated with worse baseline cognitive performance and diminished postoperative improvement on NPH symptom severity scales, gait measures, and cognitive instruments compared to patients lacking pathology.
Barton, Spencer E; Campbell, Jeffrey W; Piatt, Joseph H
2013-04-01
The authors define and examine the properties of 2 new, practice-based quality measures for the management of hydrocephalus. The Surgical Activity Rate (SAR) is defined as the number of definitive operations for the treatment of hydrocephalus performed in a neurosurgical practice over the course of a year, divided by the number of patients with hydrocephalus seen in follow-up during that year. The Revision Quotient (RQ) is defined as the number of definitive revision operations performed in a neurosurgical practice in the course of a year, divided by the number of definitive initial operations during that year for patients with newly diagnosed hydrocephalus. Using published actuarial shunt survival data, the authors conducted Monte Carlo simulations of a pediatric neurosurgical practice to illustrate the properties and interpretations of the SAR and RQ. They used data from the Kids' Inpatient Database (KID) for 2009 to calculate RQs for hospitals accounting for more than 10 admissions coded for initial CSF shunt insertions. During the initial growth phase of a simulated neurosurgical practice, the SAR approached its steady-state value much earlier than the RQ. Both measures were sensitive to doubling or halving of monthly failure rates. In the 2009 KID, 117 hospitals reported more than 10 initial shunt insertions. The weighted mean (± standard deviation) RQ for these hospitals was 1.79 ± 0.69. Among hospitals performing 50 or more initial shunt insertions, the RQ ranged between 0.71 and 3.65. The SAR and RQ have attractive qualitative features as practice-based quality measures. The RQ, at least, exhibits clinically meaningful interhospital variation as applied to CSF shunt surgery. The SAR and RQ merit prospective field-testing as measures of quality in the management of childhood hydrocephalus.
Clinical analysis of aqueductal stenosis in patients with hydrocephalus in a Kenyan setting.
Kaur, Loyal Poonamjeet; Munyiri, Nderitu Joseph; Dismus, Wekesa Vincent
2017-01-01
Aqueductal stenosis is the commonest cause of congenital hydrocephalus. The scope of this paper is to highlight the disease burden of hydrocephalus attributed to aqueductal stenosis which still remains unknown in our setting. In a descriptive cross-sectional study, 258 records of patients diagnosed with hydrocephalus were analyzed after ethical approval from Kenyatta National Hospital- University of Nairobi (KNH-UON) ethics and research committee from January 2010 to May 2016. Patients with a diagnosis of hydrocephalus due to aqueductal stenosis were included in this study. Patients age, sex, mode of delivery, associated comorbidities, presenting complaints, neurosurgical intervention performed, Kafarnosky score were recorded. Data were divided into 2 sets based on the patient's age i.e. whether < 1 year or > 12 years. Data were recorded on google data collection form and analyzed using Google spreadsheets. Out of 258 cases of hydrocephalus, 52 had aqueductal stenosis. Male to female sex ratio for this condition was 3:2. There were 25 cases < 1year and 27 cases > 12 years old who were diagnosed with hydrocephalus due to aqueductal stenosis. Associated conditions were bilateral congenital talipes equinovarus, spina bifida, Arnold Chairi malformations, meningitis and HIV. The presenting complaints differed according to the age groups. Neurosurgical interventions included Endoscopic Third Ventriculostomy (ETV) in 21 cases, insertion of Ventriculoperitoneal (VP) shunt and ETV were done in 3 cases while the rest had only insertion of VP shunt. The Kafanosky score improve from < 50 pre-op to 19 cases achieving a score of 100, six months post-op. Aqueductal stenosis contributes a significant burden of morbidity in patients with hydrocephalus. Clinical presentation differs according to patients age. Accurate diagnosis and treatment remain a cardinal to improving patient outcome.
Endoscopic-Assisted Burr Hole Reservoir and Ventricle Catheter Placement.
Antes, Sebastian; Tschan, Christoph A; Heckelmann, Michael; Salah, Mohamed; Senger, Sebastian; Linsler, Stefan; Oertel, Joachim
2017-05-01
Accurate positioning of a ventricle catheter is of utmost importance. Various techniques to ensure optimal positioning have been described. Commonly, after catheter placement, additional manipulation is necessary to connect a burr hole reservoir or shunt components. This manipulation can lead to accidental catheter dislocation and should be avoided. Here, we present a new technique that allows direct endoscopic insertion of a burr hole reservoir with an already mounted ventricle catheter. Before insertion, the ventricle catheter was slit at the tip, shortened to the correct length, and connected to the special burr hole reservoir. An intracatheter endoscope was then advanced through the reservoir and the connected catheter. This assemblage allowed using the endoscope as a stylet for shielded ventricular puncture. To confirm correct placement of the ventricle catheter, the endoscope was protruded a few millimeters beyond the catheter tip for inspection. The new technique was applied in 12 procedures. The modified burr hole reservoir was inserted for first-time ventriculoperitoneal shunting (n = 1), cerebrospinal fluid withdrawals and drug administration (n = 2), or different stenting procedures (n = 9). Optimal positioning of the catheter was achieved in 11 of 12 cases. No subcutaneous cerebrospinal fluid collection or fluid leakage through the wound occurred. No parenchymal damage or bleeding appeared. The use of the intracatheter endoscope combined with the modified burr hole reservoir provides a sufficient technique for accurate and safe placement. Connecting the ventricle catheter to the reservoir before the insertion reduces later manipulation and accidental dislocation of the catheter. Copyright © 2017 Elsevier Inc. All rights reserved.
Pereda, Daniel; García-Lunar, Inés; Sierra, Federico; Sánchez-Quintana, Damián; Santiago, Evelyn; Ballesteros, Constanza; Encalada, Juan F; Sánchez-González, Javier; Fuster, Valentín; Ibáñez, Borja; García-Álvarez, Ana
2016-09-01
Pulmonary hypertension (PH) and right ventricular (RV) dysfunction are strong predictors of morbidity and mortality among patients with congenital heart disease. Early detection of RV involvement may be useful in the management of these patients. We aimed to assess progressive cardiac adaptation and quantify myocardial extracellular volume in an experimental porcine model of PH because of aorto-pulmonary shunt using cardiac magnetic resonance (CMR). To characterize serial cardiac adaptation, 12 pigs (aorto-pulmonary shunt [n=6] or sham operation [n=6]) were evaluated monthly with right heart catheterization, CMR, and computed tomography during 4 months, followed by pathology analysis. Extracellular volume by CMR in different myocardial regions was studied in 20 animals (aorto-pulmonary shunt [n=10] or sham operation [n=10]) 3 months after the intervention. All shunted animals developed PH. CMR evidenced progressive RV hypertrophy and dysfunction secondary to increased afterload and left ventricular dilatation secondary to volume overload. Shunt flow by CMR strongly correlated with PH severity, left ventricular end-diastolic pressure, and left ventricular dilatation. T1-mapping sequences demonstrated increased extracellular volume at the RV insertion points, the interventricular septum, and the left ventricular lateral wall, reproducing the pattern of fibrosis found on pathology. Extracellular volume at the RV insertion points strongly correlated with pulmonary hemodynamics and RV dysfunction. Prolonged systemic-to-pulmonary shunting in growing piglets induces PH with biventricular remodeling and myocardial fibrosis that can be detected and monitored using CMR. These results may be useful for the diagnosis and management of congenital heart disease patients with pulmonary overcirculation. © 2016 American Heart Association, Inc.
Hamilton, Roy; Patel, Sunil; Lee, Edward B.; Jackson, Eric M.; Lopinto, Joanna; Arnold, Steven E.; Clark, Christopher M.; Basil, Anuj; Shaw, Leslie M.; Xie, Sharon X.; Grady, M. Sean; Trojanowski, John Q.
2010-01-01
To determine the impact of cortical Alzheimer disease pathology on shunt responsiveness in individuals treated for idiopathic normal pressure hydrocephalus (iNPH), 37 patients clinically diagnosed with iNPH participated in a prospective study in which performance on neurologic, psychometric, and gait measures before and 4 months after shunting was correlated with amyloid β plaques, neuritic plaques, and neurofibrillary tangles observed in cortical biopsies obtained during shunt insertion. No complications resulted from biopsy acquisition. Moderate to severe pathology was associated with worse baseline cognitive performance and diminished postoperative improvement on NPH symptom severity scales, gait measures, and cognitive instruments compared to patients lacking pathology. PMID:20687117
Marinho de Oliveira Góes Junior, Adenauer; de Campos Vieira Abib, Simone; de Seixas Alves, Maria Teresa; Venerando da Silva Ferreira, Paulo Sérgio; Carvalho de Andrade, Mariseth
2014-04-01
To evaluate vascular flow through temporary vascular shunts inserted into peripheral arteries and veins and the repercussion, on the arterial perfusion, of venous ligation and venous shunt insertion in an experimental model for damage control. Experimental study in pigs. Animals were distributed in 5 groups: group 1, right external iliac artery (EIA) shunting and right external iliac vein (EIV) ligation; group 2, right EIA shunting and right EIV shunting; group 3, right EIV ligation; group 4, right EIV shunting; group 5, no vascular shunting and no venous ligation. Flowmeters were used to measure vascular flow on right and left external iliac vessels, and blood samples were collected from the EIVs for biochemical analysis. A right anterior limb biopsy was performed before shock. Hemorrhagic shock was induced through the external right jugular vein, until the vascular flow through right iliac external artery shunt or right iliac external vein shunt (group 4) ceased or until the animal's death. After the end of the experiments, biopsies of bilateral hind limb were obtained for histologic analysis. For statistical analysis, Microsoft Office Excel 2007 and BioEstat 5.0 (2007) were used. In the absence of hemorrhagic shock, venous ligation (group 1) was associated with a 38.8% reduction (P < 0.05) and venous shunting with a 28.4% reduction on the vascular flow through the arterial shunt. When associated with hemorrhagic shock, the mean vascular flow on the right EIA was 13 mL/min and on the left EIA was 41.2 mL/min; on group 2, the right EIA flow was 8.5 mL/min and the left EIA flow was 8.1 mL/min. When associated with hemorrhagic shock, the pO2 was 25.8 mm Hg on right EIV and 33.8 mm Hg on the left EIV for group 1 (P < 0.05), whereas for group 2, the pO2 was 22.6 mm Hg on right EIV and 22.8 mm Hg on the left EIV. On group 1, serum potassium was 3.84 mEq/L on the right EIV and 3.96 mEq/L on the left EIV, whereas on group 2, it was 7.1 mEq/L on the right EIV and 5.88 mEq/L on the left EIV (P < 0.05). In the developed experimental model, venous shunting, when compared with venous ligation, offered less resistance to vascular flow through the arterial shunt and allowed a more efficient limb venous drainage than simple vein ligature. Copyright © 2014 Elsevier Inc. All rights reserved.
Lenfestey, Robert W; Smith, P Brian; Moody, M Anthony; Clark, Reese H; Cotten, C Michael; Seed, Patrick C; Benjamin, Daniel K
2007-09-01
Infection is a common and potentially devastating complication following placement of ventriculoperitoneal (VP) shunts and cerebrospinal fluid (CSF) reservoirs in neonates. The goal of this study was to determine the normal ranges for cell count parameters in neonates with VP shunts and CSF reservoirs, as well as to determine the predictive value of CSF parameters as markers of infection. The authors evaluated neonates from 150 different neonatal intensive care units of the Pediatrix Medical Group who had undergone a lumbar puncture, VP shunt insertion, or CSF reservoir placement between 1997 and 2004. Data were collected from 9704 neonates with a mean birthweight of 2573 g and a mean gestational age of 35 weeks. Of these neonates, 181 had VP shunt insertions or CSF reservoir placements. In neonates with negative CSF cultures, significant differences were found between those with and without VP shunts or CSF reservoirs when comparing red blood cell (RBC) count (620/mm' compared with 155/mm3, p < 0.05), absolute eosinophil count (4/mm3 compared with 2/mm3, p < 0.001), protein levels (179 mg/dl compared with 115 mg/dl, p < 0.001), and glucose levels (27.5 mg/dl compared with 49 mg/dl, p < 0.001). No significant difference was found between white blood cell (WBC) counts in neonates with or without VP shunts who had negative CSF cultures. The sensitivity and specificity of a cutoff value of 20 WBCs/mm3 for diagnosing meningitis in neonates with positive cultures and intraventricular drainage devices were 67% and 62%, respectively. Although differences exist between CSF parameters found in neonates with or without VP shunts or CSF reservoirs, only the difference in RBC count is large enough to be clinically significant. The authors found that the utility of CSF parameters in neonates with VP shunts or CSF reservoirs was limited due to poor diagnostic sensitivity and specificity.
Telemetric Intracranial Pressure Monitoring with the Raumedic Neurovent P-tel.
Antes, Sebastian; Tschan, Christoph A; Heckelmann, Michael; Breuskin, David; Oertel, Joachim
2016-07-01
Devices enabling long-term intracranial pressure monitoring have been demanded for some time. The first solutions using telemetry were proposed in 1967. Since then, many other wireless systems have followed but some technical restrictions have led to unacceptable measurement uncertainties. In 2009, a completely revised telemetric pressure device called Neurovent P-tel was introduced to the market. This report reviews technical aspects, handling, possibilities of data analysis, and the efficiency of the probe in clinical routine. The telemetric device consists of 3 main parts: the passive implant, the active antenna, and the storage monitor. The implant with its parenchymal pressure transducer is inserted via a frontal burr hole. Pressure values can be registered with a frequency of 1 Hz or 5 Hz. Telemetrically gathered data can be viewed on the storage monitor or saved on a computer for detailed analyses. A total of 247 patients with suspected (n = 123) or known (n = 124) intracranial pressure disorders underwent insertion of the telemetric pressure probe. A detailed analysis of the long-term intracranial pressure profile including mean values, maximum and negative peaks, pathologic slow waves, and pulse pressure amplitudes is feasible using the detection rate of 5 Hz. This enables the verification of suspected diagnoses as normal-pressure hydrocephalus, benign intracranial hypertension, shunt malfunction, or shunt overdrainage. Long-term application also facilitates postoperative surveillance and supports valve adjustments of shunt-treated patients. The presented telemetric measurement system is a valuable and effective diagnostic tool in selected cases. Copyright © 2016 Elsevier Inc. All rights reserved.
Nakae, Shunsuke; Murayama, Kazuhiro; Adachi, Kazuhide; Kumai, Tadashi; Abe, Masato; Hirose, Yuichi
2018-01-01
Although a subdural fluid collection frequently is observed, diagnostic methods that differentiate between the subdural collection caused by external hydrocephalus and that caused by subdural hygroma have not been established. Here, we report a case of external hydrocephalus caused by Gliadel-induced eosinophilic meningitis that has been previously reported in only 1 case and can be diagnosed by time-spatial labeling inversion pulse magnetic resonance imaging (time-SLIP MRI). A tumor located in the left temporal was detected incidentally in an 81-year-old man by examination of a head injury. The tumor was surgically resected and diagnosed as a high-grade glioma during the surgery; Gliadel wafers subsequently were implanted. Three weeks after the resection, the patient showed disturbed consciousness, and computed tomography revealed a subdural fluid collection. The out-flow of cerebrospinal through the resection cavity was detected by time-SLIP MRI. Cerebrospinal tests indicated high white blood cell counts and high protein levels, with more than 90% of the white blood cell count comprising eosinophils. Therefore, we suspected that the subdural fluid collection was caused by external hydrocephalus because of Gliadel-induced eosinophilic meningitis. We surgically removed the Gliadel wafers and subsequently performed a surgery to insert a ventriculoperitoneal shunt. Histologic examination indicated eosinophilic accumulation around the Gliadel wafers. The patient's symptoms improved after the insertion of a ventriculoperitoneal shunt. In the present case, time-SLIP MRI was a useful and noninvasive method for diagnosing external hydrocephalus which was caused by eosinophilic meningitis because of Gliadel-induced eosinophilic meningitis. Copyright © 2017 Elsevier Inc. All rights reserved.
Bateman, G A; Loiselle, A M
2007-01-01
Between 10 and 90% of patients with normal pressure hydrocephalus (NPH) treated with a shunt will improve but they risk significant morbidity/mortality from this procedure. NPH is treated hydrodynamically and it has been assumed that a hydrodynamic difference must exist to differentiate which patient will respond. The purpose of this study is to see whether MRI hydrodynamics can differentiate which patients will improve post shunting. Thirty-two patients with NPH underwent MRI with flow quantification measuring the degree of ventricular enlargement, sulcal compression, white matter disease, total blood inflow, sagittal sinus outflow, aqueduct stroke volume, relative compliance ratio and arteriovenous delay. Patients were followed up after shunt insertion to gauge the degree of improvement and were compared with 12 age-matched controls and 12 patients with Alzheimer's disease. 63% of patients improved with insertion. The responders were identical to the non-responders in all variables. The NPH patients were significantly different to the controls (e.g. Total blood inflow reduced 20%, sagittal sinus outflow reduced 35%, aqueduct stroke volume increased 210%, relative compliance ratio reduced 60% and arteriovenous delay reduced 57% with p = 0.007, 0.03, 0.04, 0.0002 and 0.0003 respectively. The patient's with Alzheimer's disease values were midway between the NPH and control patients. Significant hydrodynamic differences were noted between NPH and controls but these were unable to differentiate the responders from non-responders. The hydrodynamics of Alzheimer's disease makes exclusion of comorbidity from this disease difficult.
Shen, O; Valsky, D V; Messing, B; Cohen, S M; Lipschuetz, M; Yagel, S
2011-02-01
Agenesis of the ductus venosus (ADV) is a rare condition in which there are two variants of umbilical vein drainage: intrahepatic shunt or extrahepatic (portosystemic) shunt. It has been posited that the extrahepatic variant carries a poorer prognosis. However, in the absence of associated anomalies there is still a wide variation in outcome. We evaluated the portal system in cases of ADV and aimed to identify parameters that might predict outcome. We conducted a retrospective study of cases of ADV with extrahepatic shunt that had been examined in two centers, and collected new cases prospectively. The route of the shunt was depicted using two-dimensional (2D) and three-dimensional (3D) ultrasound imaging. In an attempt to characterize portal system and shunt developmental variations and their possible impact on outcome, the diameter of the shunt was compared with the diameter of the umbilical vein and the entire portal vasculature was assessed. Poor outcome was defined as persistent morbidity or fetal or neonatal death. Twenty-two cases of ADV were identified: nine retrospectively and 13 prospectively. Aberrant shunts from the umbilical vein were identified to the right atrium, coronary sinus, inferior vena cava (IVC) and iliac vein. In seven of 22 cases (32%) a wide connection was observed. In six of these seven cases (86%) the outcome was poor, including four with severe associated anomalies and two with hepatic dysfunction. In five of these cases, cardiomegaly with tricuspid regurgitation was observed, as well as underdevelopment of the portal system. In only five of 15 cases with a narrow shunt (33%) was the outcome poor, and in all five cases the poor outcome was related to associated anomalies. In cases of ADV with extrahepatic shunt, portal system development is impacted by the diameter of the shunt. If the shunt is narrow, the portal system will have developed normally. A wide shunt is associated with underdevelopment or absence of the portal system. In cases of ADV with extrahepatic shunt, prognosis is determined by the severity of associated anomalies, the diameter of the shunt and development of the portal system. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.
Loan, James J M; Mankahla, Ncedile; Meintjes, Graeme; Fieggen, A Graham
2017-10-16
Hydrocephalus is a recognised complication of human immunodeficiency virus (HIV)-related opportunistic infections. Symptomatic raised cerebrospinal fluid pressure can be treated with ventriculoperitoneal shunt insertion (VPS). In HIV-infected patients however, there is a concern that VPS might be associated with unacceptably high rates of mortality. We aim to systematically review and appraise published literature to determine reported outcomes and identify predictors of outcome following VPS in relevant subgroups of HIV-infected adults. The following electronic databases will be searched: The Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE (PubMed), EMBASE, CINAHL (EBSCOhost), LILACS (BIREME), Research Registry ( www.researchregistry.com ), the metaRegister of Controlled Trials (mRCT) ( www.controlled-trials.com ), ClinicalTrials.gov ( www.clinicaltrials.gov ) and OpenSIGLE database. Any randomised studies, cohort studies, case-control studies, interrupted time series or sequential case series reporting survival following VPS in HIV-infected individuals will be included. If high-quality homogenous studies exist, meta-analysis will be conducted to determine 1-, 6- and 12-month mortality with comparison made between underlying aetiologies of hydrocephalus. This study will generate a comprehensive review of VPS in HIV-infected patients for publication. The primary outcome of meta-analysis is 12-month survival. If only low-quality, heterogeneous studies are available, this study will demonstrate this deficiency and will be of value in justifying and aiding the design of future studies. PROSPERO CRD42016052239.
Laeke, Tsegazeab; Tirsit, Abenezer; Biluts, Hagos; Murali, Deeptha; Wester, Knut
2017-04-01
Treatment of pediatric hydrocephalus in sub-Saharan countries is associated with significant complication rates. The objective of this study is to analyze the management of hydrocephalus and complication rates of surgical intervention in the Ethiopian setting to improve future quality. A retrospective cohort study was conducted in a neurosurgical teaching hospital. Two cohorts separated by 2.5 years were analyzed. A total of 128 (58.6% male and 41.4% female) children with isolated hydrocephalus, meningomyelocele (MMC)-related hydrocephalus, or MMC without hydrocephalus were included. Their age ranged from 1 day to 5 years, for a mean age of 7.2 months (median age 2 months). One hundred thirteen patients had hydrocephalus, of whom 57 (44.5.3%) had isolated hydrocephalus and 56 (43.8%) had hydrocephalus associated with MMC. Seventy-seven (74.7%) patients underwent ventriculoperitoneal (VP) shunting, whereas 24 (23.3%) underwent endoscopic third ventriculostomy (ETV). The incidence of shunt infection was 23.4%. Reoperation was needed in 54 (52.4%) patients, with the most common indication being shunt failure. ETV failed in 14 (58.3%) of the 24 patients undergoing ETV. VP shunt insertions had unacceptably high infection rate despite the presence of a protocol for the procedure. Intraoperative guidelines should be developed further and followed strictly to reduce infections. Such measures should include restricting the number of surgeons performing the procedure. In our opinion, one should avoid insertion of a VP shunt as the primary treatment. ETV has proved to be a good alternative in other studies and the decreasing pattern of ETV failure in our study also suggest ETV as a better alternative to VP shunt. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.
Sharkawi, Eamon; Artes, Paul H; Oleszczuk, Justyna D; Bela, Cyrielle; Achache, Farid; Barton, Keith; Bergin, Ciara
2016-01-01
Evaluation of a protocol of total intraluminal occlusion of Baerveldt shunts and its effects on early postoperative intraocular pressure (IOP) control and hypotony-related complications. This was a noncomparative, prospective, and interventional study. Glaucoma patients were recruited to undergo Baerveldt shunt surgery. A total of 116 eyes of 112 patients were enrolled. During shunt implantation, aqueous outflow was restricted using an intraluminal occluding stent inserted through the entire tube length, with and without external ligation, to halt aqueous flow. Postoperatively, eyes underwent ligature laser suture lysis and partial or complete stent removals, at predetermined time intervals. Loss of postoperative IOP control was categorized as transient or persistent hypotony (IOP≤5 mm Hg) or hypertony (IOP>21 mm Hg). Patients were followed up for 1 year. Preoperatively median IOP was 23 mm Hg (mean 26 mm Hg, SD 12 mm Hg), median number of glaucoma medications was 3.0 (mean 3.0, SD 1.2). During year 1, laser suture lysis was performed in 30 eyes (26%) and stent removal in 93 eyes (80%) (23 partial; 70 complete). There was 1 case of transient hypotony, no cases of persistent hypotony, 10 of transient hypertony, and 3 of persistent hypertony. Nine eyes had IOP≤5 mm Hg at ≥1 time points and hypotony-related complications occurred in 8 eyes (7%). At 1 year, median IOP was 12 mm Hg (mean 13 mm Hg, SD 4 mm Hg) with a median of 1.0 glaucoma medications (mean 1.1, SD 1.3). The cumulative probability of failure during the first 12 months follow-up was 6% (n=7). Overall postoperative complications occurred in 11 eyes (9%). The surgical and postoperative protocol resulted in controlled, step-wise reductions of IOP with low rates of hypotony and related complications.
Haptic device for a ventricular shunt insertion simulator.
Panchaphongsaphak, Bundit; Stutzer, Diego; Schwyter, Etienne; Bernays, René-Ludwig; Riener, Robert
2006-01-01
In this paper we propose a new one-degree-of-freedom haptic device that can be used to simulate ventricular shunt insertion procedures. The device is used together with the BRAINTRAIN training simulator developed for neuroscience education, neurological data visualization and surgical planning. The design of the haptic device is based on a push-pull cable concept. The rendered forces produced by a linear motor connected at one end of the cable are transferred to the user via a sliding mechanism at the end-effector located at the other end of the cable. The end-effector provides the range of movement up to 12 cm. The force is controlled by an open-loop impedance algorithm and can become up to 15 N.
Conversion of Low-Flow Priapism to High-Flow State Using T-Shunt with Tunneling.
Mistry, Neil A; Tadros, Nicholas N; Hedges, Jason C
2017-01-01
Introduction . The three types of priapism are stuttering, arterial (high-flow, nonischemic), and venoocclusive (low-flow, ischemic). These are usually distinct entities and rarely occur in the same patient. T-shunts and other distal shunts are frequently combined with tunneling, but a seldom recognized potential complication is conversion to a high-flow state. Case Presentation . We describe 2 cases of men who presented with low-flow priapism episodes that were treated using T-shunts with tunneling that resulted with both men having recurrent erections shortly after surgery that were found to be consistent with high-flow states. Case 1 was a 33-year-old male with sickle cell anemia and case 2 was a 24-year-old male with idiopathic thrombocytopenic purpura. In both cases the men were observed over several weeks and both men returned to normal erectile function. Conclusions . Historically, proximal shunts were performed only in cases when distal shunts failed and carry a higher risk of serious complications. T-shunts and other distal shunts combined with tunneling are being used more frequently in place of proximal shunts. These cases illustrate how postoperative erections after T-shunts with tunneling can signify a conversion from low-flow to high-flow states and could potentially be misdiagnosed as an operative failure.
Congenital portosystemic shunts with and without gastrointestinal bleeding - case series.
Gong, Ying; Zhu, Hui; Chen, Jun; Chen, Qi; Ji, Min; Pa, Mier; Zheng, Shan; Qiao, Zhongwei
2015-12-01
The clinical presentation of congenital portosystemic shunt is variable and gastrointestinal bleeding is an uncommon presentation. To describe the imaging features of congenital portosystemic shunt as it presented in 11 children with (n = 6) and without gastrointestinal bleeding (n = 5). We performed a retrospective study on a clinical and imaging dataset of 11 children diagnosed with congenital portosystemic shunt. A total of 11 children with congenital portosystemic shunt were included in this study, 7 with extrahepatic portosystemic shunts and 4 with intrahepatic portosystemic shunts. Six patients with gastrointestinal bleeding had an extrahepatic portosystemic shunt, and the imaging results showed that the shunts originated from the splenomesenteric junction (n = 5) or splenic vein (n = 1) and connected to the internal iliac vein. Among the five cases of congenital portosystemic shunt without gastrointestinal bleeding, one case was an extrahepatic portosystemic shunt and the other four were intrahepatic portosystemic shunts. Most congenital portosystemic shunt patients with gastrointestinal bleeding had a shunt that drained portal blood into the iliac vein via an inferior mesenteric vein. This type of shunt was uncommon, but the concomitant rate of gastrointestinal bleeding with this type of shunt was high.
Venous Shunt Versus Venous Ligation for Vascular Damage Control: The Immunohistochemical Evidence.
Góes Junior, Adenauer Marinho de Oliveira; Abib, Simone de Campos Vieira; Alves, Maria Teresa de Seixas; Ferreira, Paulo Sérgio Venerando da Silva; Andrade, Mariseth Carvalho de
2017-05-01
To evaluate the expression of immunohistochemical markers of tissue ischemia (iNOS, eNOS, and HSP70) in a vascular damage control experimental model to determine if a venous temporary vascular shunt insertion leads to a better limb perfusion when compared with the ligature of the injured vein. Experimental study in male Sus Scrofa weighting 40 Kg. Animals were distributed into 5 groups: group 1 animals were submitted to right external iliac artery (EIA) shunting and right external iliac vein (EIV) ligation; group 2 animals were submitted to right EIA shunting and right EIV shunting; group 3 animals were submitted to right EIV ligation; group 4 animals were submitted to right EIV shunting; group 5 animals were not submitted to vascular shunting or venous ligation. Transonic Systems flowmeters were used to measure vascular flow on right and left external iliac vessels, and i-STAT (Abbot) portable blood analyzer was used for EIVs blood biochemical analysis. An initial baseline register of invasive arterial pressure, iliac vessels flow, and venous blood analysis was performed. Arterial pressure and iliac vessels flow were taken immediately after right iliac vessels shunting or ligation. Then, hemorrhagic shock was induced by continuous 20 mL/min blood withdraw from the external right jugular vein whereas arterial blood pressure and iliac vessels flow registers were taken every 10 min, and blood samples from EIVs were obtained every 30 min until the vascular flow through right EIA (or through the shunt inserted into the right EIV for group 4 animals) became inexistent or until the animal's death. After the end of the experiments, bilateral hind limb's biopsies were obtained for immunohistochemical analysis. Using image editing and analysis software, the expression of iNOS, eNOS, and HSP70 (3 well-known ischemic associated immunohistochemical markers) was assessed. The mean expression of each marker in the right hind limb was compared between groups. For statistical analysis, Microsoft Office Excel 2007 and BioEstat 5.0 (2007) were used. Immunohistochemical analysis showed no difference regarding the iNOS expression; nevertheless, both eNOS and HSP70 expression were statistically more intense (P < 0.05) on group 1 (eNOS = 1.32; HSP70 = 15.05) than on group 2 (eNOS = 0.018; HSP70 = 8.56). The higher expression of eNOS and HSP70 in the right hind limbs of group 1 animals (arterial shunt and venous ligature) than group 2 animals (arterial shunt and venous shunt) suggests that venous ligation is associated with more intense ischemic histological findings than venous shunting. Copyright © 2017 Elsevier Inc. All rights reserved.
2017-01-24
Objectives: Open surgical reconstruction using expanded polytetrafluoroethylene stent grafts to create a sutureless anastomosis is an alternative to...French Argyle shunt was inserted into one randomly assigned artery, with a self-expanding ePTFE stent deployed in the other. Arterial flow measurements...for histopathology were obtained during the terminal procedure. Results: Angiography revealed no difference in patency at 72 hours. The stent grafts
Ventriculoperitoneal Shunt Fracture Following Application of Halo-Gravity Traction: A Case Report.
Blakeney, William G; D'Amato, Charles
2015-09-01
Ventriculoperitoneal (VP) shunt malfunctions are very common, and shunt fracture is one of the most common causes. Shunt fractures are often a result of calcification and tethering, which predispose the tubing to fracture when mechanical stresses are applied. This case report describes a case of shunt fracture following application of halo-gravity traction for correction of spinal deformity. Chart and imaging data for a single case were reviewed and reported in this retrospective case study. A 10-year-old female, being treated for syndromic scoliosis, underwent posterior surgical release and application of halo-gravity traction. Increasing weight of traction was applied over a period of 6 weeks, for gradual deformity correction. It was noted on the 6-week cervical spine radiograph that the VP shunt had fractured at the base of the neck. The patient was taken to the operating room and intraoperative findings confirmed shunt fracture. This was repaired without complications. This case, to our best knowledge, is the first reported occurrence of shunt fracture following application of halo-gravity traction. It demonstrates the importance of careful monitoring of patients with VP shunts, when they are undergoing traction for correction of spinal deformity. Level IV.
Marchetti, Pablo; Razmaria, Aria; Zagaja, Greg P; Gundeti, Mohan S
2011-02-01
Infection or malfunction of ventriculo-peritoneal (VP) shunts is a severe complication during laparoscopic surgery involving the gastrointestinal or urinary tract. It has been recently suggested to externalize the shunt or convert into a ventriculo-atrial shunt to prevent this complication with laparoscopic approach. Herein, we present a novel technique for management of the VP shunt during robot-assisted laparoscopic (RAL) urologic procedures. After port placement and diagnostic peritoneoscopy, an Endopouch bag (Ethicon Endo-Surgery) was inserted into the peritoneal cavity and the distal end of the shunt was placed into the pouch. The Endopouch suture was synched around the shunt and the pouch was placed in the subhepatic space during the surgery. The intraperitoneal pressure was maintained at 12 mm Hg during the entire procedure. Metronidazole, gentamicin, and vancomycin were administered as prophylaxis. Following the completion of the surgery and profuse irrigation of the peritoneal cavity, the shunt was repositioned within the peritoneum. We evaluated perioperative shunt-related complications. We used this technique in four patients with VP shunt undergoing RAL cystoplasty and appendicovesicostomy and/or colonic enema channel formation. The average age of the patient at surgery was 10.8 (7-14) years. One patient was converted to open because of failure to progress due to multiple adhesions and the shunt was externalized temporarily. At a mean follow-up of 13 (3-20) months, no shunt-related complications were seen. In our preliminary experience, the use of an intracorporeal Endopouch bag with controlled pneumoperitoneal pressure to protect the VP shunt may be an effective alternative to prevent complications related to it during RAL urologic surgery involving the gastrointestinal or urinary tract. Further studies will be needed to confirm our results.
Congenital portosystemic shunts: prenatal manifestations with postnatal confirmation and follow-up.
Han, Byoung Hee; Park, Sung Bin; Song, Mi Jin; Lee, Kyung Sang; Lee, Young-Ho; Ko, Sun Young; Lee, Yeon Kyung
2013-01-01
The purpose of this study was to evaluate prenatal sonographic findings that could be helpful for diagnosis of congenital intrahepatic portosystemic venous shunts and the follow-up results. Six neonates with congenital shunts between the portal vein and hepatic vein were enrolled in this study. Prenatal sonography was performed in 5 cases. We categorized the cases according to a previously published classification of intrahepatic portosystemic venous shunts and retrospectively reviewed the prenatal and postnatal sonographic examinations to identify findings that might be helpful for diagnosing shunts prenatally. Follow-up sonographic examinations were done until closure of the shunts. Clinical features were also determined. According to the original reports, intrahepatic portosystemic venous shunts were diagnosed by prenatal sonography in 2 of 5 cases. In the remaining 3 cases, there were suggestive abnormal findings on retrospective review, including an abnormal intrahepatic tubular structure, a prominent hepatic vein, and congestive heart failure. Postnatal sonography showed type 2 shunts in all 6 cases. In 1 case, there were 2 type 2 lesions between two branches of the left portal vein and the middle and left hepatic veins. On follow-up sonography, 5 of the 6 congenital shunts had spontaneously closed by 11 months of age. One case was treated with coil embolization during the neonatal period. Intrauterine growth restriction was the most commonly clinical feature prenatally. Findings such as an abnormal tubular structure, a prominent hepatic vein, and congestive heart failure can be important clues for identifying congenital intrahepatic portosystemic venous shunts on prenatal sonography. The use of prenatal and postnatal sonography is feasible for detection and evaluation of these shunts.
Riva-Cambrin, Jay; Kestle, John R W; Holubkov, Richard; Butler, Jerry; Kulkarni, Abhaya V; Drake, James; Whitehead, William E; Wellons, John C; Shannon, Chevis N; Tamber, Mandeep S; Limbrick, David D; Rozzelle, Curtis; Browd, Samuel R; Simon, Tamara D
2016-04-01
OBJECT The rate of CSF shunt failure remains unacceptably high. The Hydrocephalus Clinical Research Network (HCRN) conducted a comprehensive prospective observational study of hydrocephalus management, the aim of which was to isolate specific risk factors for shunt failure. METHODS The study followed all first-time shunt insertions in children younger than 19 years at 6 HCRN centers. The HCRN Investigator Committee selected, a priori, 21 variables to be examined, including clinical, radiographic, and shunt design variables. Shunt failure was defined as shunt revision, subsequent endoscopic third ventriculostomy, or shunt infection. Important a priori-defined risk factors as well as those significant in univariate analyses were then tested for independence using multivariate Cox proportional hazard modeling. RESULTS A total of 1036 children underwent initial CSF shunt placement between April 2008 and December 2011. Of these, 344 patients experienced shunt failure, including 265 malfunctions and 79 infections. The mean and median length of follow-up for the entire cohort was 400 days and 264 days, respectively. The Cox model found that age younger than 6 months at first shunt placement (HR 1.6 [95% CI 1.1-2.1]), a cardiac comorbidity (HR 1.4 [95% CI 1.0-2.1]), and endoscopic placement (HR 1.9 [95% CI 1.2-2.9]) were independently associated with reduced shunt survival. The following had no independent associations with shunt survival: etiology, payer, center, valve design, valve programmability, the use of ultrasound or stereotactic guidance, and surgeon experience and volume. CONCLUSIONS This is the largest prospective study reported on children with CSF shunts for hydrocephalus. It confirms that a young age and the use of the endoscope are risk factors for first shunt failure and that valve type has no impact. A new risk factor-an existing cardiac comorbidity-was also associated with shunt failure.
The Electrophysiologic Effects of Acute Mitral Regurgitation in a Canine Model.
Lawrance, Christopher P; Henn, Matthew C; Miller, Jacob R; Kopek, Michael A; Zhang, Andrew J; Schuessler, Richard B; Damiano, Ralph J
2017-04-01
Atrial fibrillation (AF) occurs in 30% of patients with mitral regurgitation referred for surgical intervention. However, the underlying mechanisms in this population are poorly understood. This study examined the effects of acute left atrial volume overload on atrial electrophysiology and the inducibility of AF. Ten canines underwent insertion of an atrioventricular shunt between the left ventricle and left atrium. Shunt and aortic flows were calculated, and the shunt was titrated to a shunt fraction to 40% to 50% of cardiac output. An epicardial plaque with 250 bipolar electrodes was used to determine activation and refractory periods. Biatrial pressures and volumes, conduction times, and atrial fibrillation inducibility were recorded. Data were collected at baseline and 20 minutes after shunt opening and closure. Mean shunt flow was 1.3 ± 0.5 L/min with a shunt fraction of 43% ± 6% simulating moderate to severe mitral regurgitation. Compared with baseline, left atrial volumes and maximum pressures increased by 27% and 29%, respectively, after shunt opening. Biatrial effective refractory periods did not change significantly after shunt opening or closure. Conduction times increased by 9% with shunt opening and returned to baseline after closure. AF duration or inducibility did not change with shunt opening. This canine model of mitral regurgitation demonstrated that acute left atrial volume overload did not increase the inducibility of atrial arrhythmias in contrast with experimental and clinical findings of chronic left atrial volume overload. This suggests that the substrates for AF in patients with mitral regurgitation are a result of chronic remodeling. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Takazawa, Shinya; Uchida, Hiroo; Kawashima, Hiroshi; Tanaka, Yujiro; Sato, Kaori; Jimbo, Takahiro; Deie, Kyoichi; Koiwai, Kazuki; Nomura, Koji; Iwanaka, Tadashi
2014-08-01
A newborn female was transferred to our hospital presenting with severe respiratory distress. She underwent tracheal intubation and nasogastric tubing. Investigations revealed a congenital extrahepatic portosystemic shunt (CEPS) type 1, biliary atresia, heterotaxia, polysplenia, malrotation and a double aortic arch (DAA). She underwent the Kasai portoenterostomy and the Ladd procedure when she was 29 days old. On postoperative day 20, she developed sudden hematemesis with bright red blood. Endoscopy showed massive bleeding from an esophageal ulcer, and endoscopic therapy was performed successfully. During left thoracotomy, an aortoesophageal fistula (AEF) was detected and repaired by direct suturing. The postoperative course was uneventful. CEPS type 1 is commonly associated with other congenital malformations; however, there have been no previous reports of an association between CEPS and DAA. Nasogastric tube insertion in a patient with DAA can result in catastrophic AEF. The treatment strategy should be carefully considered in patients with CEPS type 1 and multiple congenital fetal anomalies.
Asymptomatic Congenital Intrahepatic Portosystemic Shunt.
Brown, Karen M; Hal, Hassan
2009-01-01
Congenital (spontaneous) intrahepatic portosystemic shunt is rare in the English literature. Most cases of portosystemic shunt occur after trauma, surgery, liver biopsy or as a result of chronic portal hypertension. Chronic shunting may result in encephalopathy, bleeding or hyperinsulinism. We report a case of an asymptomatic adult female with a presumed congenital intrahepatic portosystemic shunt and discuss the pertinent imaging findings and important key concepts related to this condition.
Intracranial Pressure-Guided Shunt Valve Adjustments with the Miethke Sensor Reservoir.
Antes, Sebastian; Stadie, Axel; Müller, Simon; Linsler, Stefan; Breuskin, David; Oertel, Joachim
2018-01-01
Telemetric intracranial pressure (ICP) monitoring seems to be a promising therapy-supporting option in shunt-treated patients. Benefits become obvious when headaches are unspecific and clinical symptoms cannot be related to possible overdrainage or underdrainage. In this study, we evaluated a new telemetric device to individually adjust shunt valves according to ICP measurements. Between December 2015 and November 2016, 25 patients with suspected suboptimal shunt valve settings underwent insertion of a telemetric ICP sensor (Sensor Reservoir; Christoph Miethke, Potsdam, Germany). Over a 1-year period, a total of 183 telemetric ICP measurements and 85 shunt valve adjustments were carried out. Retrospective statistic analyses focused on valve adjustments, ICP values, and clinical outcomes. ICP-guided valve adjustments positively changed the clinical state in 18 out of 25 patients. Clinical improvement over time was associated with significant changes of the valve settings and ICP values. Interestingly, a therapeutically normalized ICP profile was not automatically associated with clinical improvement. The Sensor Reservoir is an important and valuable tool for shunt-treated patients suffering from drainage-related problems. The possibility to simultaneously recognize and solve shunt problems represents the decisive advantage. Nevertheless, measurements with the Sensor Reservoir did not allow for the determination of default valve settings or universal target ICP values. Copyright © 2017 Elsevier Inc. All rights reserved.
Hart, Michael Gavin; Czosnyka, Marek; Czosnyka, Zofia Helena; Fernandes, Helen Marie
2013-01-01
Slit ventricle syndrome remains a complex entity presenting a considerable challenge to treat successfully. This study aims to demonstrate the application of dual intracranial pressure (ICP) and infusion studies together with the novel shunt occlusion test in both a diagnostic and therapeutic role. An 8-year-old child had aqueduct stenosis treated with a ventriculoperitoneal shunt (medium-pressure valve). The presentation was of headaches with papilloedema. Imaging with both computed tomography and magnetic resonance imaging revealed slit ventricles. Initially a shunt exploration revealed distal obstruction that was treated together with insertion of a paediatric strata II regular valve; however, the child continued to deteriorate. Overnight ICP monitoring revealed dramatically raised ICP with poor compensatory reserve. Intra-operative infusion study revealed a shunt that was patent distally but with proximal obstruction. A subtemporal decompression ipsilateral to the shunt was performed together with adjustment of the paediatric strata II regular valve to 2.5 in order to prevent overdrainage. This led to normalisation of ICP, resolution of papilloedema and symptomatic improvement. We demonstrate how combined ICP monitoring and shunt infusion studies can be used to help guide management. Unilateral subtemporal decompressions and preventing shunt overdrainage can result in normalisation of ICP and cerebrospinal fluid dynamics.
Woo, P Ym; Wong, H T; Pu, J Ks; Wong, W K; Wong, L Yw; Lee, M Wy; Yam, K Y; Lui, W M; Poon, W S
2016-10-01
To determine the frequency of primary ventriculoperitoneal shunt infection among patients treated at neurosurgical centres of the Hospital Authority and to identify underlying risk factors. This multicentre historical cohort study included consecutive patients who underwent primary ventriculoperitoneal shunting at a Hospital Authority neurosurgery centre from 1 January 2009 to 31 December 2011. The primary endpoint was shunt infection, defined as: (1) the presence of cerebrospinal fluid or shunt hardware culture that yielded the pathogenic micro-organism with associated compatible symptoms and signs of central nervous system infection or shunt malfunction; or (2) surgical incision site infection requiring shunt reinsertion (even in the absence of positive culture); or (3) intraperitoneal pseudocyst formation (even in the absence of positive culture). Secondary endpoints were shunt malfunction, defined as unsatisfactory cerebrospinal fluid drainage that required shunt reinsertion, and 30-day mortality. A primary ventriculoperitoneal shunt was inserted in 538 patients during the study period. The mean age of patients was 48 years (range, 13-88 years) with a male-to-female ratio of 1:1. Aneurysmal subarachnoid haemorrhage was the most common aetiology (n=169, 31%) followed by intracranial tumour (n=164, 30%), central nervous system infection (n=42, 8%), and traumatic brain injury (n=27, 5%). The mean operating time was 75 (standard deviation, 29) minutes. Shunt reinsertion and infection rates were 16% (n=87) and 7% (n=36), respectively. The most common cause for shunt reinsertion was malfunction followed by shunt infection. Independent predictors for shunt infection were: traumatic brain injury (adjusted odds ratio=6.2; 95% confidence interval, 2.3-16.8), emergency shunting (2.3; 1.0-5.1), and prophylactic vancomycin as the sole antibiotic (3.4; 1.1-11.0). The 30-day all-cause mortality was 6% and none were directly procedure-related. This is the first Hong Kong territory-wide review of infection in primary ventriculoperitoneal shunts. Although the ventriculoperitoneal shunt infection rate met international standards, there are areas of improvement such as vancomycin administration and the avoidance of scheduling the procedure as an emergency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bilbao, Jose Ignacio; Quiroga, Jorge; Herrero, Jose Ignacio
Since the insertion of the first TIPS in 1989 much has been learned about this therapeutic procedure. It has an established role for the treatment of some complications of portal hypertension: prevention of recurrent variceal bleeding and rescue of patients with acute uncontrollable variceal bleeding. In addition TIPS is useful for Budd-Chiari syndrome, refractory ascites and hepatorenal syndrome, although its specific role in these indications remains to be definitively established. However, the decrease in sinusoidal blood flow induced by TIPS can lead to the patient developing hepatic encephalopathy and liver failure in some cases. Therefore, TIPS should be used withmore » caution in patients with very poor liver function. From a technical point of view, successful placement of TIPS is achieved in more than 98% of cases by experienced groups. At present, evaluation of TIPS dysfunction based on morphology probably leads to an overdiagnosis of this complication since most of these cases are not associated with clinical manifestations (recurrent bleeding or refractory ascites). The major disadvantage of TIPS remains its poor long-term patency requiring a mandatory surveillance program. The indicator for shunt function/malfunction should be the portosystemic pressure gradient, which is best assessed by intravascular measurements. Shunt obstructions may be prevented or reduced by the use of stent-grafts in the future.« less
High Isolation Single-Pole Four-Throw RF MEMS Switch Based on Series-Shunt Configuration
Khaira, Navjot
2014-01-01
This paper presents a novel design of single-pole four-throw (SP4T) RF-MEMS switch employing both capacitive and ohmic switches. It is designed on high-resistivity silicon substrate and has a compact area of 1.06 mm2. The series or ohmic switches have been designed to provide low insertion loss with good ohmic contact. The pull-in voltage for ohmic switches is calculated to be 7.19 V. Shunt or capacitive switches have been used in each port to improve the isolation for higher frequencies. The proposed SP4T switch provides excellent RF performances with isolation better than 70.64 dB and insertion loss less than 0.72 dB for X-band between the input port and each output port. PMID:24711730
Suen, Kyle; Mashhadian, Ardavan; Figarsky, Ian; Payumo, Jeff; Liu, Antonio
2017-12-01
Shunt nephritis is a rare and relatively new diagnosis involving glomerular kidney damage following ventriculoperitoneal and ventriculoatrial shunt placement. Our case report summarizes the presentation, diagnostic workup, and management of a patient with shunt nephritis. We also review and discuss the current literature on the topic.
Long-term follow-up of successful treatment for dandy-walker syndrome (DWS).
Lin, Jun; Liang, Guobiao; Liang, Yong; Kou, Yun
2015-01-01
Various managements of Dandy-Walker syndrome (DWS) from open excision of the cysts to CSF diversion have been reported. However, optimal treatment for DWS remains elusive. Cyst fenestration was employed firstly, but failed 15 days after the surgery. Then a ventriculoperitoneal (VP) shunt was inserted and the patient discharged from hospital 13 days after the second surgery. During the 12-year follow-up, CT scanning, MRI, and X-radiation were performed. CT scanning showed that the size of ventricular system gradually returned to normal. MRI revealed similar changes of the ventricular system, and further revealed the development of supratentorial brain. The results of X-radiation during the follow-up years showed that the peritoneal end of the shunt might be already out of the abdominal cavity. Slow refilling of the shunt valve may suggest that the shunt could be probably not functional. The treatment of the patient was successfully, and the abnormal cerebral ventricle system gradually recovered during the 12-year follow-up. Because the patient might be probably independent on the shunt, further choice of the shunt removal should be thinking thoroughly, considering both safety and quality of life for the patient.
Long-term follow-up of successful treatment for dandy-walker syndrome (DWS)
Lin, Jun; Liang, Guobiao; Liang, Yong; Kou, Yun
2015-01-01
Background: Various managements of Dandy-Walker syndrome (DWS) from open excision of the cysts to CSF diversion have been reported. However, optimal treatment for DWS remains elusive. Methods: Cyst fenestration was employed firstly, but failed 15 days after the surgery. Then a ventriculoperitoneal (VP) shunt was inserted and the patient discharged from hospital 13 days after the second surgery. During the 12-year follow-up, CT scanning, MRI, and X-radiation were performed. Results: CT scanning showed that the size of ventricular system gradually returned to normal. MRI revealed similar changes of the ventricular system, and further revealed the development of supratentorial brain. The results of X-radiation during the follow-up years showed that the peritoneal end of the shunt might be already out of the abdominal cavity. Slow refilling of the shunt valve may suggest that the shunt could be probably not functional. Conclusion: The treatment of the patient was successfully, and the abnormal cerebral ventricle system gradually recovered during the 12-year follow-up. Because the patient might be probably independent on the shunt, further choice of the shunt removal should be thinking thoroughly, considering both safety and quality of life for the patient. PMID:26770421
Parylene MEMS patency sensor for assessment of hydrocephalus shunt obstruction.
Kim, Brian J; Jin, Willa; Baldwin, Alexander; Yu, Lawrence; Christian, Eisha; Krieger, Mark D; McComb, J Gordon; Meng, Ellis
2016-10-01
Neurosurgical ventricular shunts inserted to treat hydrocephalus experience a cumulative failure rate of 80 % over 12 years; obstruction is responsible for most failures with a majority occurring at the proximal catheter. Current diagnosis of shunt malfunction is imprecise and involves neuroimaging studies and shunt tapping, an invasive measurement of intracranial pressure and shunt patency. These patients often present emergently and a delay in care has dire consequences. A microelectromechanical systems (MEMS) patency sensor was developed to enable direct and quantitative tracking of shunt patency in order to detect proximal shunt occlusion prior to the development of clinical symptoms thereby avoiding delays in treatment. The sensor was fabricated on a flexible polymer substrate to eventually allow integration into a shunt. In this study, the sensor was packaged for use with external ventricular drainage systems for clinical validation. Insights into the transduction mechanism of the sensor were obtained. The impact of electrode size, clinically relevant temperatures and flows, and hydrogen peroxide (H2O2) plasma sterilization on sensor function were evaluated. Sensor performance in the presence of static and dynamic obstruction was demonstrated using 3 different models of obstruction. Electrode size was found to have a minimal effect on sensor performance and increased temperature and flow resulted in a slight decrease in the baseline impedance due to an increase in ionic mobility. However, sensor response did not vary within clinically relevant temperature and flow ranges. H2O2 plasma sterilization also had no effect on sensor performance. This low power and simple format sensor was developed with the intention of future integration into shunts for wireless monitoring of shunt state and more importantly, a more accurate and timely diagnosis of shunt failure.
Clinical and economic consequences of antibiotic-impregnated cerebrospinal fluid shunt catheters.
Eymann, Regina; Chehab, Somar; Strowitzki, Martin; Steudel, Wolf-Ingo; Kiefer, Michael
2008-06-01
The authors evaluated the safety and efficacy of antibiotic-impregnated shunt catheters (AISCs) and determined the cost-benefit ratio related to the fact that AISCs increase the implant costs of a shunt procedure by approximately $400 per patient. The control group comprised 98 adults with chronic hydrocephalus and 22 children, who were treated without AISCs (non-AISCs). In the treatment group, AISCs (Bactiseal, Codman, Johnson & Johnson) were implanted in 171 adults and 26 children. The minimum follow-up period was 6 months. Important risk factors for shunt infections (such as age, comorbidity, cause of hydrocephalus, operating time, and duration of external cerebrospinal fluid drainage prior to shunt placement) did not differ between the study and control groups. In the pediatric AISC group, the frequency of premature, shunt-treated infants and the incidence of external ventricular drainage prior to shunt insertion were actually higher than those in the non-AISC group. When using AISCs, the shunt infection rate dropped from 4 to 0.6% and from 13.6 to 3.8% in the adult and the pediatric cohort, respectively. Overall the infection rate decreased from 5.8 to 1%, which was statistically significant (p = 0.0145). The average costs of a single shunt infection were $17,300 and $13,000 in children and adults, respectively. The cost-benefit calculation assumed to have saved shunt infection-related costs of approximately $50,000 in 197 AISC-treated patients due to the reduction in shunt infection rate in this group compared with costs in the control group. Despite the incremental implant costs associated with the use of AISCs, the overall reduction in infection-related costs made the use of AISCs cost beneficial in the authors' department. From clinical and economic perspectives, AISCs are seemingly a valuable addition in hydrocephalus therapy.
Park, Yong Sook; Nam, Taek Kyun
2017-03-01
We describe a technique to clip a large internal carotid artery (ICA) aneurysm via a retrograde suction decompression (RSD). A large aneurysm in the right distal ICA involving the bifurcation region measuring 1.2×1.1×0.7 cm with posterior projection was managed with assisted RSD technique. The anterior choroidal artery emerged from the side wall of the aneurysm. An Inahara shunt was inserted into the ICA with neck dissection, and RSD was applied after completely clipping the aneurysm. RSD with an Inahara carotid shunt is useful for complete visualization of the aneurysm, including its surrounding structures, and for proximal control of the parent vessels, subsequently achieving satisfactory clip placement.
Two cases of esophageal cancer with portal hypertension: esophagectomy with venous shunt procedure.
Kato, T; Motohara, T; Kaneko, Y; Shikishima, H; Okushiba, S; Kondo, S; Kato, H
2001-01-01
We performed venous shunt procedure in the reconstruction of the esophagus after esophagectomy using the gastric tube in two cases of esophageal cancer with portal hypertension due to liver cirrhosis. In both cases, the short-term postoperative course was uneventful, without congestion in the gastric tube. In Case 1 where the short gastric vein had been used as the shunt vein, the long-term postoperative course was also uneventful, without hepatic encephalopathy or hemorrhage from deterioration of the varices of the gastric tube. However, in Case 2 where the left gastroepiploic vein had been used, hepatic encephalopathy developed due to excessive shunt flow. These results suggested that appropriate shunt flow could be expected by using short gastric vein.
Laser restoration of flow in occluded ventricular shunts for pediatric neurosurgery
NASA Astrophysics Data System (ADS)
Christens-Barry, William A.; Guarnieri, Michael; Carson, Benjamin S.
1998-01-01
We have investigated the use of short pulses of infrared ((lambda) equals 2.09 micrometers ) light from a Ho:YAG laser to photofragment occlusions and restore flow in ventricular shunts, which provide the sole means of maintaining proper intracranial pressure in hydrocephalus patients. These experiments employed model tissues, a polymeric model compound, and patient explants in order to determine appropriate pulse energies and delivery rates for removal of occlusions material. Laser energy doses and rates of occlusion removal were established for these materials. Laser energy doses that do not damage the shunt device or surrounding tissue were identified. Optical fibers (25 ga. or smaller) can be introduced through the dome of current shunt devices and threaded to the occlusion site. Clinical application will require the continued development of an introducer tool for the transcutaneous insertion of the optical fiber into the shunt device and irrigation techniques for removing the occlusion detritus generated by photofragmentation treatment. Using this approach, a minimally invasive and benign procedure for in situ restoration of flow in occluded neurological implant devices becomes possible.
Francel, P C; Stevens, F A; Tompkins, P; Pollay, M
2001-02-01
The proper functioning of shunt valves in vivo is dependent on many factors, including the valve itself, the anti-siphon device or ASD (if included), patency of inlet and outlet tubing, and location of the valve. One important, but sometimes overlooked, consideration in valve function is the valve location relative to the tip of the ventricular inlet catheter. As with any pressure measurement, the zero or reference position is an important concept. In the case of shunt valves, the position of the proximal inlet catheter tip is fixed and therefore serves as the reference point for all pressure measurements. This study was conducted to document the importance of this relationship for the pressure/flow characteristics of the shunt valve. We bench-tested differential pressure valves (with integral anti-gravity devices; AGDs) from three manufacturers. Valves were connected to an "infinite" reservoir, and the starting head pressure for each was determined from product inserts. The inlet catheter tip was fixed at this position, and the valve body was moved in relation to the inlet catheter tip. Outflow rates were determined gravimetrically for positions varying between 4 cm above and 8 cm below the inlet catheter tip. All differential pressure valves utilized in this study that contained AGDs showed significant increases in outflow rate as the valve body was moved incrementally below the level of the inlet catheter tip. To allow functioning as a zero-hydrostatic pressure differential pressure valve, the AGD and the inlet catheter tip should be aligned at the same horizontal level.
Ventricular shunt tap as a predictor of proximal shunt malfunction in children: a prospective study.
Rocque, Brandon G; Lapsiwala, Samir; Iskandar, Bermans J
2008-06-01
The clinical diagnosis of cerebrospinal fluid (CSF) shunt malfunction can be challenging. In this prospective study, the authors evaluated a common method of interrogating shunts: the shunt tap; specifically, its ability to predict proximal malfunction. The authors performed standardized shunt taps in a consecutive series of cases involving children with suspected or proven shunt malfunction, assessing flow and, when possible, opening pressure. Data were collected prospectively, and results analyzed in light of surgical findings. A shunt tap was performed prior to 68 operative explorations in 51 patients. Of the 68 taps, 28 yielded poor or no CSF flow on aspiration. After 26 of these 28 procedures, proximal catheter obstruction was identified. After 28 taps with good CSF return and normal or low opening pressure, 18 shunts were found to have a proximal obstruction, 8 had no obstruction, and 2 had a distal obstruction. Another 12 taps with good CSF flow had high opening pressure; subsequent surgery showed distal obstruction in 11 of the shunts, and proximal obstruction in 1. The positive predictive value of poor flow was 93%, while good flow on shunt tap predicted adequate proximal catheter function in only 55% of cases. Poor flow of CSF on shunt tap is highly predictive of obstruction of the proximal catheter. Because not all patients with good flow on shunt tap underwent surgical shunt exploration, the specificity of this test cannot be determined. Nonetheless, a shunt tap that reveals good flow with a normal opening pressure can be misleading, and management of such cases should be based on clinical judgment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, Deepak, E-mail: deepakjain02@yahoo.com; Arora, Ankur, E-mail: aroradrankur@yahoo.com; Deka, Pranjal, E-mail: drpranjaldeka@gmail.com
2013-08-01
A case of surgically created splenorenal shunt complicated with shunt myelopathy was successfully managed by placement of a stent graft within the splenic vein to close the portosystemic shunt and alleviate myelopathy. To our knowledge, this is the first report of a case of shunt myelopathy in a patient with noncirrhotic portal fibrosis without cirrhosis treated by a novel technique wherein a transjugular intrahepatic route was adopted to deploy the stent graft.
Prophylactic ethamsylate for periventricular haemorrhage.
Cooke, R W; Morgan, M E
1984-01-01
Drug prophylaxis with ethamsylate for periventricular haemorrhage in very low birthweight infants significantly reduced the incidence of periventricular haemorrhage in survivors. A reduction in abnormalities at follow up and in insertion of ventriculoperitoneal shunts was also noted. PMID:6696506
CAD of 0.1- to 10-GHz GaAs MMIC SPST switch
NASA Astrophysics Data System (ADS)
Yadav, Ramchandra; Kirty, V. S. R.
1998-04-01
The design of the SPST switch provides an insertion loss less than 2 dB, isolation more than 40 dB and return loss better than 17.5 dB in the frequency range of 0.1 GHz to 10 GHz. The insertion loss is improved by treating SPST switch as a 50 (Omega) artificial transmission line with incorporation of inductor in series arm and the capacitance of MESFET in the shunt arm. High isolation is ensured by the lower value of `ON' resistance of MESFET in shunt arm. Also good return loss is achieved by paralleling a 50 (Omega) resistor with capacitance of MESFET in series arm. The absence of DC blocking capacitors and replacement of large value bias chokes with 5 K(Omega) resistors effectively improved the performance of SPST switch at low frequency and also reduced the chip size. The overall chip dimension is 2.2 mm X 1.7 mm.
Congenital Shunts of the Portal Venous System: Case-series of Uncommon Shunts.
Santos, Liliana; Nobre, Susana; Laezza, Nadia; Cunha, Catarina; Gonçalves, Isabel; Lopes, Maria F
Congenital shunts of the portal venous system are rare entities that can present in children with clinical heterogeneity. To evaluate the clinical course of children with uncommon shunts presenting to our institution and examine the available literature on this topic. Medical records of children with rare forms of congenital shunts were retrospectively reviewed for demographics, symptoms, management, and outcome between 2003 and 2016. Three female patients with congenital shunts, including a congenital mesenterico-portal Rex shunt (n = 1) and congenital portosystemic shunts (CPSS) (n = 2), were referred for surgical evaluation between ages 4 and 9. Median follow-up was 8 years (range, 6-13 years). One asymptomatic patient did not require treatment and remained disease-free during long-term follow-up. The other 2 patients with CPSS and unusual symptoms, including liver focal nodular hyperplasia (FNH) in infancy (n = 1) and bleeding from esophageal varices (n = 1), showed subsequent progression to liver nodules that were managed by endovascular shunt occlusion. One patient showed symptom resolution and the other showed stable lesions at last follow-up. Literature yielded descriptions of two cases of congenital mesenterico-portal Rex shunt, one case of coincident CPSS and FNH in infancy, but zero reports of bleeding from esophageal varices. This case series examines each distinct patient's presentation, discusses the diagnosis, management and outcome and compares findings while discussing literature on this topic. A high index of suspicion and familiarity with unusual forms and treatment options is required to allow timely diagnosis and appropriate treatment.
Vibration reduction of a woven composite fan blade by piezoelectric shunted devices
NASA Astrophysics Data System (ADS)
Thierry, Olivier; De Smet, Olivier; Deü, Jean-François
2016-09-01
This study concerns the vibration reduction in the low frequency range of a composite fan blade of a turbojet engine with piezoelectric devices. The interest is to increase lifespan and avoid flutter phenomena by reducing the vibration amplitude. The solution considered in the work consists in using piezoelectric elements connected to a passive electric circuit usually called shunt. The use of woven composite materials for fan blades enables to plan on embedding piezoelectric materials, for instance in the form of patches inserted between the composite and the coating material. The work presented during this conference will illustrate the feasibility of a piezoelectric shunted device integrated in an industrial application that doesn't require electrical supply. For such a structure, it is shown that a purely passive resonant shunt can significantly reduce the level of vibration of the second bending mode and that a good correlation between experiments and simulations validates the best fitting finite element model.
Should ventriculoatrial shunting be the procedure of choice for normal-pressure hydrocephalus?
McGovern, Robert A; Kelly, Kathleen M; Chan, Andrew K; Morrissey, Nicholas J; McKhann, Guy M
2014-06-01
Ventriculoatrial (VA) shunting is rarely used for patients with normal-pressure hydrocephalus (NPH), likely due to surgeon technical preference and case reports indicating cardiopulmonary complications. However, these complications have typically been limited to adults in whom VA shunts had been placed when they were children. Few studies have directly compared VA shunting to ventriculoperitoneal (VP) shunting in cases of NPH. The authors retrospectively analyzed all NPH patients treated by a single surgeon at their center from January 2002 through December 2011. Thirty patients were treated with VA shunts (14 male) and 157 with VP shunts (86 male). The patients' mean age (± SD) at surgery was 73.7 ± 9.4 years for VA shunting and 76.0 ± 8.2 years for VP shunting; the median durations of follow-up were 42.0 months (IQR 19.2-63.6 months) and 34.2 months (IQR 15.8-67.5), respectively. Statistical analysis was performed using chi-square tests and Wilcoxon rank-sum tests. Perioperative and postoperative complications for VA and VP shunting cohorts, respectively, included distal revision (2.7% vs 6.6%, p = 0.45), proximal revision (2.7% vs 2.5%, p = 0.97), and postoperative seizure (2.7% vs 1.5%, p = 0.62). Shunt drainage-related subdural hematomas/hygromas developed in 8.1%/27.0% of VA shunt-treated patients versus 6.6%/26.4% of VP shunt-treated patients (p = 0.76/0.98) and were nearly always successfully managed with programmable-valve adjustment. Symptomatic intracerebral hemorrhage (1.5%) and shunt infection (2.0%) were only observed in those who underwent VP shunting. Of note, no cardiovascular complications were observed in any patient, and there were no cases of distal occlusion of the VA shunt. The authors found no significant differences in complication rates between VA and VP shunting, and VA shunting was not associated with any cardiopulmonary complications. Thus, in the authors' experience, VA shunting is at least as safe as VP shunting for treating NPH.
Post ventriculoperitoneal shunt abdominal pseudocyst: Challenges posed in management.
Hamid, Raashid; Baba, Aejaz A; Bhat, Nisar A; Mufti, Gowhar; Mir, Younis A; Sajad, Wani
2017-01-01
In patients with hydrocephalus, the abdominal cavity has been used for absorption of cerebrospinal fluid (CSF) since 1905. Ventriculoperitoneal (VP) shunt operation is followed by abdominal complications in about 5-47% cases. Abdominal CSF pseudo cyst is an uncommon, but well described complication. This survey was conducted to study the clinical profile and management of this entity. We present our experience with cases of CSF pseudo cyst in children. Retrospective analysis of 4 cases diagnosed to have abdominal pseudo cyst following VP shunt between 2008 and 2013. All the four cases were suspected clinically and diagnosis was confirmed by abdominal ultrasonography. In three patients, the cyst was multilocular and of varying size. Fourth one had a unilocular cyst at the lower end of VP shunt. All the four patients had features of varying degree raised intracranial pressure and a two patients had abdominal signs also. All the patients needed open exploration. Cyst fluid was drained and partial to complete excision of the cyst was done along with the repositioning of the shunt in abdominal cavity in three patients and exteriorization of shunt in one patient. Patients were followed for any further complication over a period of 1-year. Abdominal pseudo cyst is a rare complication after VP Shunt and could result in shunt malfunction or abdominal symptoms and signs. Whenever suspected it should be confirmed by imaging, followed by open exploration and repositioning of the shunt.
Ventriculoperitoneal shunt infection in Haji Adam Malik Hospital, Medan
NASA Astrophysics Data System (ADS)
Dharmajaya, R.
2018-03-01
Installation of ventriculoperitoneal shunts (VP) represented a substantial progress in the neurosurgical management of hydrocephalus in children. However, infection is the most commonpostoperative complication of aventriculoperitoneal shunt. It is important because it is related to substantial morbidity and mortality, and exerts a negative impact on the quality of life of patients. We retrospectively analyzed all 20 cases of shunt infection from 2013 to 2016. The types of infections found were exposed shunts15 cases (75%), and 5 cases of ventriculitis (25%). Length of infection time which calculated from the beginning of surgery was 350.20 days or 11 months. The most common pathogen types are S. epidermidis followed by P. aeruginosa, E. coli, and A. baumanii. There were many risk factors for shunt infection, but the interesting fact was the level of pre-operative albumin. There was a significant difference between low albumin levels (<3.0) and normal albumin (≥3.0) levels against the risk of exposure shunt, p = 0.015. It means there is asignificant difference between low pre-operative albumin and normal level for the risk of theexposed shunt.
Thomas, George; McGirt, Matthew J; Woodworth, Graeme; Heidler, Jennifer; Rigamonti, Daniele; Hillis, Argye E; Williams, Michael A
2005-01-01
To evaluate neurocognitive changes and predict neurocognitive outcome after ventriculoperitoneal shunting for idiopathic normal pressure hydrocephalus (INPH). Reports of neurocognitive response to shunting have been variable and studies that predict cognitive outcomes after shunting are limited. We reviewed our experience with cognitive outcomes for INPH patients who were selected for shunting based on abnormal cerebrospinal fluid (CSF) pressure monitoring and positive response in any of the NPH symptoms following large volume CSF drainage. Forty-two INPH patients underwent neurocognitive testing and Folstein Mini-Mental State Examination (MMSE) prior to shunting. Neurocognitive testing or MMSEwere performed at least 3 months after shunt insertion. Significant improvement in a neurocognitive subtest was defined as improvement by one standard deviation (1 SD) for the patient's age, sex and education level. Significant improvement in overall neurocognitive outcome was defined as a 4-point improvement in MMSE or improvement by 1 SD in 50% of the administered neurocognitive subtests. Nonparametric tests were used to assess changes. Predictors of outcome were assessed via logistic regression analysis. Twenty-two patients (52.3%) showed overall neurocognitive improvement, and significant improvement was seen in tests of verbal memory and psychomotor speed. Predictive analysis showed that patients scoring more than 1 SD below mean at baseline on verbal memory immediate recall were fourfold less likely to show overall cognitive improvement, and sixfold less likely if also associated with visuoconstructional deficit or executive dysfunction. Verbal memory scores at baseline were higher in patients who showed overall cognitive improvement. Shunting INPH patients on the basis of CSF pressure monitoring and drainage response shows a significant rate of cognitive improvement, and baseline neurocognitive test scores may distinguish patients likely to respond to shunt surgery from those who will not. Copyright (c) 2005 S. Karger AG, Basel.
Sharma, Ruchi; Suddle, Abid; Quaglia, Alberto; Peddu, Praveen; Karani, John; Satyadas, Thomas; Heaton, Nigel
2015-10-01
Congenital extrahepatic portosystemic shunt, also known as Abernethy malformation, is a rare congenital malformation. It causes shunting of blood through a communication between the portal and systemic veins such as a patent ductus venous. We report 3 cases of Abernethy malformation complicated by the development of hepatocellular carcinoma. Additionally, we comprehensively reviewed all previously reported cases and highlighted common features that may help in early diagnosis and appropriate management. Patients with Abernethy malformation may have an increased propensity to develop hepatocellular carcinoma. All 5 previously reported cases, plus the three of our patients, have a type 1 (complete) shunt suggesting a role for absent portal blood flow in the pathogenesis of hepatocellular carcinoma. Congenital extrahepatic portosystemic shunt should be sought for in cases with raised serum ammonia, hepatic encephalopathy or hepatocellular carcinoma in the absence of cirrhosis.
Post ventriculoperitoneal shunt abdominal pseudocyst: Challenges posed in management
Hamid, Raashid; Baba, Aejaz A.; Bhat, Nisar A.; Mufti, Gowhar; Mir, Younis A.; Sajad, Wani
2017-01-01
Background: In patients with hydrocephalus, the abdominal cavity has been used for absorption of cerebrospinal fluid (CSF) since 1905. Ventriculoperitoneal (VP) shunt operation is followed by abdominal complications in about 5-47% cases. Abdominal CSF pseudo cyst is an uncommon, but well described complication. Aim: This survey was conducted to study the clinical profile and management of this entity. We present our experience with cases of CSF pseudo cyst in children. Materials and Methods: Retrospective analysis of 4 cases diagnosed to have abdominal pseudo cyst following VP shunt between 2008 and 2013. All the four cases were suspected clinically and diagnosis was confirmed by abdominal ultrasonography. Results: In three patients, the cyst was multilocular and of varying size. Fourth one had a unilocular cyst at the lower end of VP shunt. All the four patients had features of varying degree raised intracranial pressure and a two patients had abdominal signs also. All the patients needed open exploration. Cyst fluid was drained and partial to complete excision of the cyst was done along with the repositioning of the shunt in abdominal cavity in three patients and exteriorization of shunt in one patient. Patients were followed for any further complication over a period of 1-year. Conclusion: Abdominal pseudo cyst is a rare complication after VP Shunt and could result in shunt malfunction or abdominal symptoms and signs. Whenever suspected it should be confirmed by imaging, followed by open exploration and repositioning of the shunt. PMID:28413525
Suchorska, B; Kunz, M; Schniepp, R; Jahn, K; Goetz, C; Tonn, J C; Peraud, A
2015-04-01
In idiopathic normal pressure hydrocephalus (NPH) ventriculoperitoneal (VP) shunt insertion is the method of choice to improve cardinal symptoms such as gait disturbance, urge incontinence and/or dementia. With reduced compliance, the brain of the elderly is prone for overdrainage complications. This was especially true with the use of differential pressure valve implantation. The present study compares clinical outcome and complication rates after VP shunt insertion with differential pressure valves in the early years and gravitational valves since 2005. The authors reviewed patients treated at our institution for NPH since 1995. Differential pressure valves were solely used in the initial years, while the treatment regimen changed to gravitational valves in 2005. Clinical improvement/surgical success rates as well as complications were compared between the two groups. Eighty-nine patients were enrolled for the present study. Mean age at the time of surgery was 73.5 ± 6.3 years. Male patients predominated with 73, compared with 16 female patients. Median follow-up time was 28 ± 26 months. Date of last follow-up was 1st October 2013. Forty-nine patients received a gravitational valve, while 40 were treated with differential pressure valves. In the gravitational group a significant improvement was observed after shunt insertion for gait disorder, cognitive impairment and urge incontinence (p < 0.0001, resp. p = 0.004), while a significant change in the differential pressure group was only seen for gait disorder (p = 0.03) but not for cognition or urinary incontinency (p > 0.05). The risk of hygroma as a sign of shunt overdrainage requiring surgical intervention was significantly higher in the differential pressure group (5 versus 0 in the gravitational group). Patients with NPH treated with gravitational valves in the present cohort showed a more profound improvement in their initial symptoms, including gait disorder, cognitive impairment and urinary incontinency without the risk of overdrainage complications requiring surgical intervention when compared with patients who received differential pressure valves in previous years.
Takeuchi, Hajime; Takeda, Yoko; Takahashi, Miyo; Hayashi, Shogo; Fukuzawa, Yoshitaka; Nakano, Takashi
2014-09-01
To observe a case of congenital extrahepatic portosystemic shunt and discuss it from the embryological and clinical viewpoints. An 85-year-old female cadaver was employed for a dissection course at Aichi Medical University in 2009. There was no evidence of liver cirrhosis macroscopically or microscopically. A portosystemic shunt was observed that involved communication between the inferior mesenteric vein, inferior vena cava (IVC), and left ovarian vein by a single Y-shaped shunt vessel. To the best of our knowledge, this is the first reported case of the above-mentioned three veins being connected by a single Y-shaped shunt vessel. Considering the other venous diameters, the shunt appeared to flow into the splenic vein and IVC. It cannot be denied that this shunt may have led to hepatic encephalopathy, although the shunt effect may have been minimal. Embryological development of IVC appears to occur close to the plexus of anastomosing vitelline veins, forming the portal vein.
Surgical strategy according to the anatomical types of congenital portosystemic shunts in children.
Matsuura, Toshiharu; Takahashi, Yoshiaki; Yanagi, Yusuke; Yoshimaru, Koichiro; Yamamura, Kenichiro; Morihana, Eiji; Nagata, Hazumu; Uike, Kiyoshi; Takada, Hidetoshi; Taguchi, Tomoaki
2016-12-01
Congenital portosystemic shunts (CPSS) with intrahepatic portal vein (IHPV) hypoplasia or absence cause encephalopathy or pulmonary hypertension (PH). Acute shunt closure may result in postoperative portal hypertension. The aim of this study was to propose a surgical strategy according to the anatomical types of CPSS and IHPV. Twenty-three CPSS patients were diagnosed from1990 to 2015. All patients were evaluated by computed tomography, angiography, and PV pressure monitoring under a shunt occlusion test. CPSS were categorized into 5 types according to the anatomical shunt location. The median age at diagnosis was 34months. Three of 23 total patients, who had an extrahepatic portosystemic shunt with a hypoplastic IHPV, died before treatment initiation because of severe PH. Fourteen cases received surgical or interventional treatment at the median age of 5years. A total of 6 cases received surgical therapy, including liver transplants for 2 absent IHPV cases. The remaining 8 cases received interventional coiling. All shunt ligations were successfully accomplished in 1-stage ligation without any complications. After the treatment, the hypoplastic IHPV gradually enlarged with an efficient portal inflow. A precise pretreatment anatomical evaluation of CPSS and IHPV types is mandatory for the selection of surgical treatment. Diagnostic study - level II and treatment study - level III. Copyright © 2016 Elsevier Inc. All rights reserved.
Laparoscopic correction of congenital portosystemic shunt in children.
Kimura, Takuya; Soh, Hideki; Hasegawa, Toshimichi; Sasaki, Takashi; Kuroda, Seika; Yuri, Etani; Tomoda, Kaname; Fukuzawa, Masahiro
2004-10-01
Congenital portosystemic shunt is a rare clinical entity that may progress to jaundice, severe encephalopathy, and pulmonary hypertension and require surgical correction or coil embolization. We present a novel approach to the management of children with congenital portosystemic shunt by means of a minimally invasive surgical technique. Congenital portosystemic shunts were identified between the superior mesenteric vein and inferior vena cava in case 1 and between the splenic vein and left renal vein in case 2. Both of them were successfully ligated by laparoscopic approach, and catheters were subsequently replaced to monitor portal venous pressure. The patients tolerated the procedure well, and short-term results were excellent. Laparoscopic ligation of congenital portosystemic shunt is technically feasible and less invasive to the management of patients with congenital portosystemic shunts, preventing late onset, life-threatening complications.
Outcome of intrahepatic portosystemic shunt diagnosed prenatally.
Francois, Bérengère; Gottrand, Fréderic; Lachaux, Alain; Boyer, Corinne; Benoit, Bernard; De Smet, Stéphanie
2017-12-01
We analyzed the characteristics of the population with congenital portosystemic shunt diagnosed during the antenatal period and the organization of their perinatal care. This multicentric retrospective study included all the patients with a prenatal diagnosis of congenital portosystemic shunt. Between 1999 and 2015, 12 patients were included. Prenatal diagnosis was done at a median 26.5 weeks of gestation (21-34). All the patients presented intrahepatic CPSS, three of them had associated congenital cardiopathy, and one a Bannayan-Zonana syndrome. Ten patients had simple outcome on conservative treatment, eight of them having a spontaneous closure of their portosystemic shunt within the first 2 years of life. One patient had surgical treatment which failed and he developed a focal nodular hyperplasia. Another patient had radiological interventional closure of his shunt which was complicated by a venal portal thrombosis. Outcome of intrahepatic portosystemic shunt diagnosed prenatally is good in the majority of cases. What is known: • Multiples studies exist on congenital porto systemic shunt but when the diagnosis is done after birth. • The evolution, management, and complication are well known. What is new: • There is very few studies with only patients diagnosed in antenatal and it is a large series of cases. • Outcome of intrahepatic portosystemic shunt diagnosed prenatally is good in the majority of cases.
Jayakumar, S; Odulaja, A; Patel, S; Davenport, M; Ade-Ajayi, N
2015-07-01
To report the outcomes of children who underwent Sengstaken-Blakemore tube (SBT) insertion for life-threatening haemetemesis. Single institution retrospective review (1997-2012) of children managed with SBT insertion. Patient demographics, diagnosis and outcomes were noted. Data are expressed as median (range). 19 children [10 male, age 1 (0.4-16) yr] were identified; 18 had gastro-oesophageal varices and 1 aorto-oesophageal fistula. Varices were secondary to: biliary atresia (n=8), portal vein thrombosis (n=5), alpha-1-anti-trypsin deficiency (n=1), cystic fibrosis (n=1), intrahepatic cholestasis (n=1), sclerosing cholangitis (n=1) and nodular hyperplasia with arterio-portal shunt (n=1). Three children deteriorated rapidly and did not survive to have post-SBT endoscopy. The child with an aortooesophageal fistula underwent aortic stent insertion and subsequently oesophageal replacement. Complications included gastric mucosal ulceration (n=3, 16%), pressure necrosis at lips and cheeks (n=6, 31%) and SBT dislodgment (n=1, 6%). Six (31%) children died. The remaining 13 have been followed up for 62 (2-165) months; five required liver transplantation, two underwent a mesocaval shunt procedure and 6 have completed endoscopic variceal obliteration and are under surveillance. SBT can be an effective, albeit temporary, life-saving manoeuvre in children with catastrophic haematemesis. Copyright © 2015 Elsevier Inc. All rights reserved.
Morphology of congenital portosystemic shunts involving the left colic vein in dogs and cats.
White, R N; Parry, A T
2016-05-01
To describe the anatomy of congenital portosystemic shunts involving the left colic vein in dogs and cats. Retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. For inclusion a shunt involving the left colic vein with recorded intraoperative mesenteric portovenography or computed tomography angiography along with direct gross surgical observations at the time of surgery was required. Six dogs and three cats met the inclusion criteria. All cases had a shunt which involved a distended left colic vein. The final communication with a systemic vein was variable; in seven cases (five dogs, two cats) it was via the caudal vena cava, in one cat it was via the common iliac vein and in the remaining dog it was via the internal iliac vein. In addition, two cats showed caudal vena cava duplication. The morphology of this shunt type appeared to be a result of an abnormal communication between either the left colic vein or the cranial rectal vein and a pelvic systemic vein (caudal vena cava, common iliac vein or internal iliac vein). This information may help with surgical planning in cases undergoing shunt closure surgery. © 2016 British Small Animal Veterinary Association.
Lee, Sae Ah; Lee, Young Seok; Lee, Kun Song; Jeon, Gyeong Sik
2010-01-01
A congenital intrahepatic portosystemic shunt is a rare anomaly; but, the number of diagnosed cases has increased with advanced imaging tools. Symptomatic portosystemic shunts, especially those that include hyperammonemia, should be treated; and various endovascular treatment methods other than surgery have been reported. Hepatic masses with either an intra- or extrahepatic shunt also have been reported, and the mass is another reason for treatment. Authors report a case of a congenital intrahepatic portosystemic shunt with a hepatic mass that was successfully treated using a percutaneous endovascular approach with vascular plugs. By the time the first short-term follow-up was conducted, the hepatic mass had disappeared.
Simultaneous Umbilical Hernia Repair with Transumbilical Ventriculoperitoneal Shunt Placement.
Montalbano, Michael J; Loukas, Marios; Oakes, W Jerry; Tubbs, R Shane
2017-01-01
Recently, placement of a ventriculoperitoneal shunt via a transumbilical approach has been reported. Herein, we report the repair of an umbilical hernia via the same incision and introduction of the distal end of a ventricultoperitoneal shunt into the peritoneal cavity in 3 patients. A case illustration is included. Both hernia repair and placement of the distal end of the ventriculoperitoneal shunt were uncomplicated in our small case series. To our knowledge, simultaneous repair of an umbilical hernia followed by transumbilical shunt placement has not been reported. As umbilical hernias are so common in infants, this finding, based on our experience, should not exclude placement of peritoneal tubing in the same setting. © 2017 S. Karger AG, Basel.
Cerebrospinal fluid drainage for syringomyelia.
Williams, B; Sgouros, S; Nenji, E
1995-12-01
Twenty-eight years of experience with syringomyelia of various causes in the syringomyelia clinic at the Midland Centre for Neurosurgery and Neurology has provided a database of 723 patients, mostly adults, with either hindbrain herniation, syringomyelia or both. Treatment of syringomyelia by drainage has never been the optimum primary treatment on the basis that the cavity is usually secondary to some other disturbance of the cerebrospinal fluid pathways. Over this period 73 patients had either syrinx drainage (56 syringopleural, 14 syringo-subarachnoid shunts) or other procedure such as myelotomy and cord transection. Ten years after operation only 53.5% and 50% of these two groups respectively continued to remain clinically stable. A complication rate of 15.7% included fatal haemorrhage, infection and displacement of drains. At second operation or necropsy at least 5% of shunts were found to be blocked. All the shunts were inserted without a valve and the lowering of the intrasyrinx pressure has therefore been energetic when the lower end of the drainage tube has been taken to the pleural or peritoneal cavities. This produced collapse of the cord cavities around the tip of the drainage tube and increased the likelihood of blockage. If the mechanisms which were responsible for the syringomyelia were still operative then recurrence was likely to occur alongside the drainage tube leaving the tube immured in the wall of the syrinx cavity. When hydrocephalus was present, in addition treatment of the hydrocephalus by a valved shunt to the peritoneum or to the right atrium was often effective in improving the syringomyelia. This treatment has also been used in patients without hydrocephalus. The mechanisms of improvement were unclear but this treatment stratagem has nevertheless been employed in 45 cases. In 30 out of these 45 cases the drainage of cerebrospinal fluid from outside the syrinx cavities seemed to be worthwhile; 10 patients suffered some form of complication, most of which were reversible; 8 patients were worse following surgery. It is concluded that both drainage of the syringomyelia cavity and also extra-syrinx drainage may have a place in the management of difficult syringomyelia problems although the primary treatment should be to establish the patency of CSF pathways in both hindbrain-related and non-hindbrain-related cases.
Distal splenorenal shunt (DSS) in children: analysis of the first 21 consecutive cases.
Maksoud, J G; Mies, S
1982-01-01
Twenty-one children from the ages of 4 to 12 years old were treated for esophageal hemorrhage by distal splenorenal shunt (DSS). In four patients, thrombosis of the shunt occurred within the first 24 hours after operation. In the other 17 children, long-term shunt patency was verified. Only one thrombosis has occurred in the last 15 consecutive cases. The patients were followed from one-half to six years. Late angiographic studies were performed in five patients. Forward flow through the portal vein was demonstrated in all patients. In addition, collateralization between the portomesenteric (PM) and gastrosplenic (GS) compartments was present in each case. In four patients with a wide-open shunt, the direction of collateral flow was from the PM to the GS compartment. In one child in whom the shunt was partially obstructed, the flow was from the GS to the PM compartment. In all 17 successful cases, esophageal variceal hemorrhage ceased, and there were no instances of hepatic encephalopathy. It is concluded that DSS is a safe and effective surgical procedure for the treatment of esophageal bleeding in children. Images Fig. 1. Fig. 2. Fig. 3. Fig. 4. Fig. 5. PMID:6978110
Xu, Songtao; Sheng, Weixin; Qiu, Yufa; Wang, Jianguo
2016-01-01
Ventriculoperitoneal (V-P) shunt surgery is the most common technique used for the treatment of hydrocephalus. The migration of ventriculoperitoneal shunt to the bladder is rare. Only two cases have been previously reported in the literature. We report on a 38-year-old male who had hydrocephalus and V-P shunt for 12 years. Two years ago, he found himself with recurrent urinary tract infections, haematuria and urges incontinence, and then he was diagnosed with bladder perforation and merge stones. The patient had an abdominal operation to cut off and take out the shunt catheter, as well as a transurethral holmium laser lithotripsy. Bladder perforation and stones are rare examples of complications in V-P surgical procedures. Controlling the effective length of the terminal V-P shunt and modifying it appropriately can effectively reduce these complications.
Shunts to divert aqueous humor to distant epithelialized cavities after keratoprosthesis surgery.
Dohlman, Claes H; Grosskreutz, Cynthia L; Chen, Teresa C; Pasquale, Louis R; Rubin, Peter A D; Kim, Eva C; Durand, Marlene
2010-02-01
Glaucoma is a frequent and often severe problem in patients needing keratoprosthesis (KPro) surgery. Standard glaucoma shunts in these cases often develop a very dense capsule that obstructs flow and causes intraocular pressure elevation. Therefore, we developed shunts that deliver aqueous to distant epithelialized cavities where an obstructing capsule is less likely to form. In this retroactive study of such shunts, the risk of postoperative infection (especially endophthalmitis) has been assessed. Ahmed shunts were connected with a tube to the lacrimal sac or ethmoid sinuses. In subsequent designs the polypropylene plate was eliminated, the valve was enclosed and a distal tube added (New World Medical Inc, Rancho Cucamonga, CA). The latter shunts were connected to the maxillary sinus or lower lid fornix. Between 2001 and 2005 the devices were implanted in 34 patients with very severe ocular disease. (31 had KPro implanted). Thus, the distal tube was led to the lacrimal sac (2 cases), to the ethmoid sinuses (6), to the maxillary sinus (16 cases), and to the lower lid fornix (10 cases). The patients were followed for cumulatively 145 shunt years, with a mean follow-up of 4 years and 3 months. They were instructed to administer low-dose topical antibiotics indefinitely. Only 1 case of acute bacterial endophthalmitis occurred, thus an incidence of 0.7% per shunt year. A slow-growing Mycobacterium was cultured in a disintegrating eye and 1 bacterial maxillary sinusitis occurred, both in autoimmune diseases. Three valves became exposed and had to be removed (1 replaced). Four eyes developed hypotony, probably from valve failure. The shunt arrangement, which connects the anterior chamber to potentially microbe-populated cavities or to the lower lid fornix and its flora, might be suspected to allow rapid retrograde invasion of infective agents, resulting in endophthalmitis. In this series of KPro patients, however, the incidence of severe infection was very low, in fact comparable to that after standard trabeculectomy.
Yamakawa, Akira; Fujita, Atsushi; Tanaka, Hirotomo; Ikeda, Mitsuru; Morikawa, Masashi; Kohmura, Eiji
2017-07-01
Tentorial dural arteriovenous fistulas(dAVFs)are a rare clinical entity accounting for less than 10% of all intracranial dAVFs. Because these lesions are characterized by high hemorrhagic risk, aggressive treatment should be considered. Although the number of reported cases treated with endovascular transarterial embolization(TAE)using glue has been increasing, little is known about the transvenous approach. Here, we report the case of a patient with a tentorial dAVF who was successfully treated with transvenous embolization(TVE)through venous drainage using a double catheterization technique. A 68-year-old male patient who had a history of left putaminal hemorrhage treated with a craniotomy was diagnosed with a tentorial dAVF on a magnetic resonance angiogram. Because the patient refused another craniotomy for surgical interruption of the dAVF, an endovascular approach was considered. We first attempted to perform TAE with glue, but catheterization into the tortuous meningohypophyseal trunk failed. We then performed a TVE of the venous drainage near the shunt with detachable coils and achieved complete obliteration of the fistula. During coil embolization of the venous drainage, insertion of small coils near the shunt was supported by another anchor coil that was delivered using a double catheterization technique. The method of TVE through venous drainage using a double catheterization technique, which involved placing coils in the fragile drainage vein, was safe and effective in a case of tentorial dAVF. This technique should be considered as another option for the management of complex tentorial dAVFs.
Candidal infections of ventriculoperitoneal shunts.
Baradkar, V P; Mathur, M; Sonavane, A; Kumar, S
2009-07-01
Although ventriculoperitoneal (VP) shunt infection is a common complication of shunt procedures, fungal infection is considered to be rare. In the present study, we performed retrospective analysis of six cases in which candida infection occurred. In all these six cases, VP shunt was performed in children for hydrocephalus and the onset of symptoms varied between seven days to one month after the surgical procedure was performed. The commonest clinical signs and symptoms were fever (100%), vomiting (100%), and altered sensorium (50%). The commonest isolate was Candida albicans (66.66%) followed by Candida parapsilosis and Candida glabrata in one case each. All the patients were successfully treated with Amphotericin B and there was no mortality recorded.
Congenital portosystemic shunt: characterization of a multisystem disease.
Sokollik, Christiane; Bandsma, Robert H J; Gana, Juan C; van den Heuvel, Meta; Ling, Simon C
2013-06-01
Congenital portosystemic shunts (CPSSs) are rare but increasingly recognized as a cause of important multisystem morbidity. We present new cases and a systematic literature review and propose an algorithm for the identification and care of affected patients. We reviewed the charts of consecutive patients seen in our pediatric liver clinic between 2003 and 2010 and systematically reviewed the literature of cases with CPSS. We identified 316 published cases and 12 patients in our own clinic. Of the published cases (177 male), 185 had an extrahepatic and 131 an intrahepatic portosystemic shunt. Diagnosis was made at any age, from prenatal to late adulthood. Cardiac anomalies were found in 22% of patients. The main complications were hyperammonemia/neurological abnormalities (35%), liver tumors (26%), and pulmonary hypertension or hepatopulmonary syndrome (18%). The spectrum of neurological involvement ranged from changes in brain imaging, subtle abnormalities on neuropsychological testing, through learning disabilities to overt encephalopathy. Spontaneous shunt closure occurred mainly in infants with intrahepatic shunts. Therapeutic interventions included shunt closure by surgery or interventional radiology techniques (35%) and liver transplantation (10%) leading to an improvement of symptoms in the majority. These findings mirror the observations in our own patients. In this largest review of the reported clinical experience, we identify that children with CPSS may present with otherwise unexplained developmental delay, encephalopathy, pulmonary hypertension, hypoxemia, or liver tumors. When CPSS is diagnosed, children should be screened for all of these complications. Spontaneous closure of intrahepatic shunts may occur in infancy. Closure of the shunt is indicated in symptomatic patients and is associated with a favorable outcome.
Spontaneous Intrahepatic Portal Venous Shunt: Presentation and Endovascular Treatment.
Sheth, Nakul; Sabbah, Nathanael; Contractor, Sohail
2016-07-01
Spontaneous intrahepatic portal venous shunts are rare with only few case reports published. Treatments using various endovascular techniques have been described, although no single technique has been shown to be preferred. We present a patient who was referred for treatment of a spontaneous portal venous shunt and describe our treatment approach and present a review on previously reported cases. © The Author(s) 2016.
Fisher, N; McCafferty, I; Dolapci, M; Wali, M; Buckels, J; Olliff, S; Elias, E
1999-01-01
BACKGROUND—The role of percutaneous hepatic vein angioplasty in the management of Budd-Chiari syndrome has not been well defined. Over a 10 year period at our unit, we have often used this technique in cases of short length hepatic vein stenosis or occlusion, reserving surgical mesocaval shunting for cases of diffuse hepatic vein occlusion or failed angioplasty. AIMS—To review the outcome of angioplasty and surgical shunting to define their respective roles. PATIENTS—All patients treated by angioplasty or surgical shunting for non-malignant hepatic vein obstruction over a ten year period from 1987 to 1996. METHODS—A case note review of pretreatment features and clinical outcome. RESULTS—Angioplasty was attempted in 21 patients with patent hepatic vein branches and was succesful in 18; in three patients treatment was unsuccessful and these patients had surgical shunts. Fifteen patients were treated by surgical shunting only. Mortality according to definitive treatment was 3/18 following angioplasty and 8/18 following surgery; in most cases this reflected high risk status prior to treatment. Venous or shunt reocclusion rates were similar for both groups and were associated with subtherapeutic warfarin in half of these cases. Most surviving patients in both groups are asymptomatic although one surgical patient has chronic hepatic encephalopathy. CONCLUSION—With appropriate case selection, many patients with Budd-Chiari syndrome caused by short length hepatic vein stenosis or occlusion may be managed successfully by angioplasty alone. Medium term outcome is good following this procedure provided that anticoagulation is maintained. Further follow up is required to assess for definitive benefits but we suggest that this should be included as a valid initial approach in the algorithm for management of Budd-Chiari syndrome. Keywords: Budd-Chiari syndrome; short length hepatic vein stenosis; hepatic vein occlusion; percutaneous hepatic vein angioplasty; mesocaval shunt PMID:10075967
Sharma, Ashwani Kumar; Gaikwad, Shailesh; Gupta, Vipul; Garg, Ajay; Mishra, Nalini K
2008-04-01
Since it was first described, normal pressure hydrocephalus (NPH) and its treatment by means of cerebrospinal fluid (CSF) shunting have been the focus of much investigation. Whatever be the cause of NPH, it has been hypothesized that in this disease there occurs decreased arterial expansion and an increased brain expansion leading to increased transmantle pressure. We cannot measure the latter, but fortunately the effect of these changes (increased peak flow velocity through the aqueduct) can be quantified with cine phase-contrast magnetic resonance imaging (MRI). This investigation was thus undertaken to characterize and measure CSF peak flow velocity at the level of the aqueduct, before and after lumbar CSF drainage, by means of a phase-contrast cine MRI and determine its role in selecting cases for shunt surgery. 37 patients with clinically suspected NPH were included in the study. Changes in the hyperdynamic peak CSF flow velocity with 50 ml lumbar CSF drainage (mimicking shunt) were evaluated in them for considering shunt surgery. 14 out of 15 patients who were recommended for shunt surgery, based on changes peak flow velocity after lumbar CSF drainage, improved after shunt surgery. None of the cases which were not recommended for shunt surgery, based on changes in CSF peak flow velocity after lumbar CSF drainage, improved after shunt surgery (2 out of 22 cases). The study concluded that the phase-contrast MR imaging, done before and after CSF drainage, is a sensitive method to support the clinical diagnosis of normal pressure hydrocephalus, selecting patients of NPH who are likely to benefit from shunt surgery, and to select patients of NPH who are not likely to benefit from shunt surgery.
Lee, Sae Ah; Lee, Young Seok; Lee, Kun Song
2010-01-01
A congenital intrahepatic portosystemic shunt is a rare anomaly; but, the number of diagnosed cases has increased with advanced imaging tools. Symptomatic portosystemic shunts, especially those that include hyperammonemia, should be treated; and various endovascular treatment methods other than surgery have been reported. Hepatic masses with either an intra- or extrahepatic shunt also have been reported, and the mass is another reason for treatment. Authors report a case of a congenital intrahepatic portosystemic shunt with a hepatic mass that was successfully treated using a percutaneous endovascular approach with vascular plugs. By the time the first short-term follow-up was conducted, the hepatic mass had disappeared. PMID:20808706
Krauss, Philipp; Fritz-Naville, Marco; Regli, Luca; Stieglitz, Lennart Henning
2018-01-01
Since the 1950s cerebrospinal fluid (CSF) shunt dependency has no longer been a contradiction to normal life, including sexuality and pregnancy in women, because of advances in the understanding of hydrocephalus and shunt technology. Although pregnancy in shunt-dependent women is rare, it causes uncertainty among treating physicians. We report the case of a 34-year-old pregnant woman with a ventriculoperitoneal shunt. Throughout her pregnancy she experienced progressive symptoms of CSF underdrainage without any signs of other pregnancy-related complications. After the delivery of a healthy infant, shunt resistance had to be readjusted to prepregnancy levels. A comprehensive review of the literature reports in English, listed in PubMed, is provided. Conservative treatment of pregnancy-related functional underdrainage by consecutive valve pressure adjustment is possible, easy, and safe. Copyright © 2017 Elsevier Inc. All rights reserved.
Hydrocephalus treatment in children: long-term outcome in 975 consecutive patients.
Beuriat, Pierre-Aurelien; Puget, Stephanie; Cinalli, Giuseppe; Blauwblomme, Thomas; Beccaria, Kevin; Zerah, Michel; Sainte-Rose, Christian
2017-07-01
OBJECTIVE Hydrocephalus remains one of the more common pathologies managed in pediatric neurosurgical units. Endoscopic third ventriculostomy (ETV) has an advantage over ventriculoperitoneal shunting as it enables patients to remain device free. Multiple shunt devices with various valve designs exist, with no one valve proven to be superior to another. The aim of this study was to describe the management of hydrocephalus and its long-term outcome. METHODS The authors retrospectively reviewed the medical records of all patients who had been treated for hydrocephalus at the Hôpital Necker-Enfants Malades in the period from 1985 to 1995. RESULTS Nine hundred seventy-five children had been treated for hydrocephalus. The mean follow-up was 11 ± 7.4 years (mean ± standard deviation). The most common cause of hydrocephalus was tumor related (32.3%), followed by malformative (24.5%) and inflammatory (20.9%) causes. Two hundred eighty patients underwent ETV as the first-line treatment. The procedure was effective in controlling hydrocephalus due to posterior fossa tumors and aqueductal stenosis. Six hundred ninety-five children had initial shunt insertion, with the majority receiving an Orbis-Sigma valve (OSV). The overall OSV shunt survival was 70% at 1 year, 58% at 10 years, and 49% at 20 years. The most common cause for mechanical shunt failure was obstruction (50.7%). Overall shunt survival was statistically different between the OSV and the differential-pressure valve (p = 0.009). CONCLUSIONS Endoscopic third ventriculostomy is effective in the management of childhood hydrocephalus. Its success is directly related to the underlying pathology. In the long term, the OSV has significantly higher event-free shunt survival than the classic differential-pressure valve systems.
NASA Astrophysics Data System (ADS)
Scheidler, Justin J.; Asnani, Vivake M.
2017-03-01
This paper presents a linear model of the fully-coupled electromechanical behavior of a generally-shunted magnetostrictive transducer. The impedance and admittance representations of the model are reported. The model is used to derive the effect of the shunt’s electrical impedance on the storage modulus and loss factor of the transducer without neglecting the inherent resistance of the transducer’s coil. The expressions are normalized and then shown to also represent generally-shunted piezoelectric materials that have a finite leakage resistance. The generalized expressions are simplified for three shunts: resistive, series resistive-capacitive, and inductive, which are considered for shunt damping, resonant shunt damping, and stiffness tuning, respectively. For each shunt, the storage modulus and loss factor are plotted for a wide range of the normalized parameters. Then, important trends and their impact on different applications are discussed. An experimental validation of the transducer model is presented for the case of resistive and resonant shunts. The model closely predicts the measured response for a variety of operating conditions. This paper also introduces a model for the dynamic compliance of a vibrating structure that is coupled to a magnetostrictive transducer for shunt damping and resonant shunt damping applications. This compliance is normalized and then shown to be analogous to that of a structure that is coupled to a piezoelectric material. The derived analogies allow for the observations and equations in the existing literature on structural vibration control using shunted piezoelectric materials to be directly applied to the case of shunted magnetostrictive transducers.
Anesthetic management of a case of armored brain.
Gupta, Surender Kumar; Pandia, Mihir Prakash
2015-01-01
Armored brain is condition, which occurs due to calcification in a chronic subdural hematoma (SDH). Here, we are reporting a case of armored brain due to chronic SDH as a complication of vetriculoperitoneal shunt (VP shunt). Patient had undergone major surgery for removal of calcified hematoma. VP shunt is a simple surgery, but can lead to catastrophic complications like this. In this report, we had described this condition and its aspects.
Cardioscopic tricuspid valve repair in a beating ovine heart.
Umakanthan, Ramanan; Ghanta, Ravi K; Rangaraj, Aravind T; Lee, Lawrence S; Laurence, Rita G; Fox, John A; Mihaljevic, Tomislav; Bolman, Ralph M; Cohn, Lawrence H; Chen, Frederick Y
2009-04-01
Open heart surgery is commonly associated with cardiopulmonary bypass and cardioplegic arrest. The attendant risks of cardiopulmonary bypass may be prohibitive in high-risk patients. We present a novel endoscopic technique of performing tricuspid valve repair without cardiopulmonary bypass in a beating ovine heart. Six sheep underwent sternotomy and creation of a right heart shunt to eliminate right atrial and right ventricular blood for clear visualization. The superior vena cava, inferior vena cava, pulmonary artery, and coronary sinus were cannulated, and the blood flow from these vessels was shunted into the pulmonary artery via a roller pump. The posterior leaflet of the tricuspid valve was partially excised to create tricuspid regurgitation, which was confirmed by Doppler echocardiography. A 7.0-mm fiberoptic videoscope was inserted into the right atrium to visualize the tricuspid valve. Under cardioscopic vision, an endoscopic needle driver was inserted into the right atrium, and a concentric stitch was placed along the posterior annulus to bicuspidize the tricuspid valve. Doppler echocardiography confirmed reduction of tricuspid regurgitation. All animals successfully underwent and tolerated the surgical procedure. The right heart shunt generated a bloodless field, facilitating cardioscopic tricuspid valve visualization. The endoscopic stitch resulted in annular plication and functional tricuspid valve bicuspidization, significantly reducing the degree of tricuspid regurgitation. Cardioscopy enables less invasive, beating-heart tricuspid valve surgery in an ovine model. This technique may be useful in performing right heart surgery without cardiopulmonary bypass in high-risk patients.
Ackerman, Laurie L; Fulkerson, Daniel H; Jea, Andrew; Smith, Jodi L
2018-04-01
OBJECTIVE Patients with shunts often interact with providers distant from their primary hospital, making it important that the parent(s)/guardian(s) is well versed in the type of shunt implanted and symptoms of malfunction/infection. This is particularly important with magnetic-sensitive programmable valves, as the use of MRI becomes more prevalent. METHODS Over a 6-month period, primary caregivers of 148 consecutive patients who received shunts were prospectively administered questionnaires at clinic visits. Caregivers were asked to do the following: 1) identify shunt valve name, type, and setting if applicable; 2) list symptoms of shunt malfunction/infection; and 3) indicate whether they had access to references regarding shunt type/setting, booklets from the Hydrocephalus Association, and quick reference cards with symptoms of shunt malfunction/infection. One cohort of caregivers (n = 75) was asked to carry informational cards with shunt valve/setting information (group I); this cohort was compared with another subgroup of caregivers (n = 73) not carrying cards (group II). RESULTS The mean (± SD) age of patients at implantation/revision was 3.71 ± 4.91 years, and the age at follow-up was 6.12 ± 5.4 years. The average time from surgery to administration of the questionnaire was 2.38 ± 3.22 years. There were 86 new shunt insertions and 62 revisions. One hundred twenty-eight caregivers (87%) could identify the type of valve (programmable vs nonprogrammable). On the other hand, only 72 caregivers (49%) could identify the valve name. Fifty-four of 73 (74%) caregivers of patients who had shunts with programmable valves could correctly identify the valve setting. One hundred caregivers (68%) had a copy of the Hydrocephalus Association booklet, and 103 (70%) had quick reference cards. Eighty caregivers (54%) had references on shunt type/setting. Most caregivers (127 [86%]) could name ≥ 3 signs/symptoms of shunt malfunction, with vomiting (61%), headache (49%), and sleeps more/lethargic (35%) most frequently reported. Caregivers of patients in group I were more likely to have cards with symptoms of shunt infection or malfunction (p = 0.015); have information cards regarding shunt type/setting (p < 0.001); and correctly identify valve type (p = 0.001), name (p < 0.001), and setting if programmable (p = 0.0016). There were no differences in ability to list symptoms of shunt malfunction or infection (p = 0.8812) or in access to Hydrocephalus Association booklets (p = 0.1288). There were no significant demographic differences between the groups, except that group I patients had a shorter time from surgery to last follow-up (1.66 vs 3.17 years; p = 0.0001). CONCLUSIONS Education regarding the care of patients with shunts by providing written cards with shunt type/setting and access to reference materials seems to be effective. Developing plans for guided instruction with assessment in the clinic setting of a caregiver's knowledge is important for patient safety.
Morphology of splenocaval congenital portosystemic shunts in dogs and cats.
White, R N; Parry, A T
2016-01-01
To describe the anatomy of congenital portosystemic shunts involving the splenic vein communicating with the caudal vena cava at the level of the epiploic foramen. A retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. Ninety-eight dogs and eight cats met the inclusion criteria of a congenital portosystemic shunt involving the splenic vein communicating with the prehepatic caudal vena cava plus recorded intra-operative mesenteric portovenography or computed tomography angiography and gross observations at surgery. All cases (both dogs and cats) had a highly consistent shunt that involved a distended gastrosplenic vein that communicated with the caudal vena cava at the level of the epiploic foramen via an anomalous left gastric vein. The morphology of the shunt type described appeared to be a result of an abnormal communication between the left gastric vein and the caudal vena cava and the subsequent development of preferential blood flow through an essentially normal portal venous system. The abnormal communication (shunt) was through the left gastric vein and not the splenic vein, as might have been expected. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2015 British Small Animal Veterinary Association.
Long-term Follow-up of a Case of Gold Shunt Surgery for Refractory Silicone Oil–induced Glaucoma
Le, Ryan; Berger, Alan R.
2016-01-01
Purpose: To report the first case of gold shunt surgery for treatment of silicone oil–induced refractory glaucoma in a tertiary care academic center, with 5-year follow-up. Design: The study design is a case report. Participants: The participant was a patient who underwent gold shunt surgery. Methods: Institutional Research Ethics Board approval for the study was obtained. A diabetic patient was referred for refractory glaucoma with a history of proliferative diabetic retinal detachment, and surgery with silicone oil. She was uncontrolled on maximal medical therapy and following informed consent, gold shunt surgery was performed. Ocular outcomes and number of medications were reviewed over a 5-year period. Results: Following uncomplicated surgery, intraocular pressure was reduced from 41 to 14 mm Hg, and the number of medications was reduced from 4 to 1. Glaucomatous optic neuropathy remained stable. Conclusions: Gold shunt surgery in this challenging case of silicone oil refractory glaucoma provided long-term intraocular pressure control and reduced need for medication over a 5-year period. PMID:27253968
Reichman, Trevor W; Anthony, Tiffany; Testa, Giuliano
2011-02-01
The Rex shunt is a mesenteric vein to left portal vein decompressive shunt used for the treatment of portal vein thrombosis and portal hypertension. Its use has been reported primarily in the pediatric population where portal vein thrombosis occurs with some frequency. The shunt is thought to represent a more physiologic shunt, since it restores hepatopedal blood flow through the liver. This report describes the use of this shunt in an adult who had frequent gastrointestinal bleeding secondary to extrahepatic portal vein thrombosis, which occurred as a complication after a pancreaticoduodenectomy.
Morphology of congenital portosystemic shunts emanating from the left gastric vein in dogs and cats.
White, R N; Parry, A T
2013-09-01
To describe the anatomy of congenital portosystemic shunts emanating from the left gastric vein in dogs and cats. A retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. Forty-six dogs and 27 cats met the inclusion criteria of a congenital portosystemic shunt emanating from the left gastric vein. Of the 46 dogs, 28 (61%) had a shunt that entered the left phrenic vein, 10 (22%) had a shunt that entered the post hepatic caudal vena cava and in 8 (17%) the shunt entered the azygos vein. Of the 27 cats, 19 (70%) had a shunt that entered the left phrenic vein and 8 (30%) had a shunt that entered the post hepatic caudal vena cava. The systemic vein into which the shunt entered was consistent showing three common presentations: left gastro-phrenic, left gastro-caval and left gastro-azygos. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2013 British Small Animal Veterinary Association.
Anesthetic management of a case of armored brain
Gupta, Surender Kumar; Pandia, Mihir Prakash
2015-01-01
Armored brain is condition, which occurs due to calcification in a chronic subdural hematoma (SDH). Here, we are reporting a case of armored brain due to chronic SDH as a complication of vetriculoperitoneal shunt (VP shunt). Patient had undergone major surgery for removal of calcified hematoma. VP shunt is a simple surgery, but can lead to catastrophic complications like this. In this report, we had described this condition and its aspects. PMID:25558206
Predisposing Factors for Spontaneous Closure of Congenital Portosystemic Shunts.
Paganelli, Massimiliano; Lipsich, José E; Sciveres, Marco; Alvarez, Fernando
2015-10-01
In a review of 382 cases of congenital portosystemic shunt, we found that presentation with neonatal cholestasis strongly predicts spontaneous closure of intrahepatic shunts (OR 8.3, 95% CI 3.4-20.2). Spontaneous closure before the 24th month of age is more likely for distal or multiple shunts, but rare for patent ductus venosus. Copyright © 2015 Elsevier Inc. All rights reserved.
Scrotal migration of ventriculoperitoneal shunt: a case report at Haji Adam Malik hospital, Medan
NASA Astrophysics Data System (ADS)
Dharmajaya, R.
2018-03-01
Ventriculoperitoneal (VP) shunting is one of the most common pediatric neurosurgery operations performed for dealing with hydrocephalus. We report an unusual case of a 1-year-old child with communicating hydrocephalus, who experienced right scrotum swelling after 11 months of shunting. Abdominal x-ray showed the shunt tubing, which was kinked in its distal portion of thescrotum. Ultrasound examination was performed, revealing hydrocele along with the presence of thedistal catheter in the scrotum. The patient underwent distal catheter trimming via laparoscopic approach with general surgery and managed with asuccessful outcome. Prompt surgical management of catheter repositioning is recommended to avoid the risk of further complications.
[Intrathoracic migration of a ventriculoperitoneal shunt catheter: a case report].
Sánchez-Medina, Yanire; Domínguez-Báez, Jaime; Lazo-Fernández, Eglis; Pérez Del Rosario, Pedro Antonio; Zanabria-Ortiz, Robert
2015-01-01
The intrathoracic complications from ventriculoperitoneal shunt placement are very rare. However, they are potentially serious if not treated. We report the case of thoracic migration of a peritoneal catheter after ventriculoperitoneal shunt and we also review the literature references with discussion of the different mechanisms of shunt-tip migration described. No case of previous sternotomy as in our patient has been found published. All reports recommend early catheter repositioning into the peritoneal cavity after diagnosing the migration described, to prevent worse complications. Moreover, it is important to keep in mind that intrathoracic migration can happen and it is necessary to palpate the catheter continuously during passage through subcutaneous tunnelling to prevent it. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.
[Congenital intrahepatic venous shunt as a cause of hepatic encephalopathy].
Cosme Jiménez, A; Bujanda Fernández de Piérola, L; Poch Zapiraín, M; Orcolaga Alba, R; Ojeda Pérez, E; Arenas Miravé, J I
1995-11-01
Macroscopic intrahepatic portosystemic shunts are extremely rare and may be due to liver injury, congenital vascular malformations or pathologic collaterals secondary to portal hypertension. Forty-eight cases have been reported in the literature up to 1994 with 50-60% presenting cerebral manifestations and 40% being associated with cirrhosis. The case of a patient without cirrhosis who was admitted for upper digestive hemorrhage secondary to gastroduodenal ulcer is described. At 48 hours the patient had an episode of hepatic encephalopathy coinciding with bleeding reactivation. Abdominal echography suggested communication between the right portal and suprahepatic veins and posterior angiography confirmed the diagnosis. Color Doppler echography determined shunt and portal vein blood flow. No case of intrahepatic portosystemic venous shunt as a cause of encephalopathy was found to have been reported in the Spanish literature.
Roohi, Fereydoon; Mann, David; Kula, Roger W
2005-06-01
Paget's disease of bone is a chronic progressive skeletal disorder usually occurring in the long bones and skull of older adults and elderly persons. In the skull, softening of the skull base may lead to basilar impression and consequently obstruction of the cerebrospinal fluid through the basilar cisterns, resulting ventricular enlargement in association with gait difficulties, incontinence and dementia: a syndrome resembling normal pressure hydrocephalus. The optimal management of hydrocephalus associated with Paget's disease of the skull is not well documented and is still debated. We report a patient with hydrocephalic dementia linked to Paget's disease of the skull who showed marked sustained improvement in her neurological condition after ventriculo-peritoneal shunt insertion. We have now followed this patient for 6 years. Our experience supports the view that ventricular shunting is the procedure of choice for treating hydrocephalus linked to the Paget's disease of bone and is best carried out in the early stages of the illness.
Clinical outcomes of temporary shunting for infants with cerebral pseudomeningocele.
Mattei, Tobias A; Sambhara, Deepak; Bond, Brandon J; Lin, Julian
2014-02-01
Although in the case of subdural collections temporary shunting has been suggested as a viable alternative for definitive drainage of the accumulated fluid until restoration of the normal CSF dynamics, there is no agreement on the best management strategy for pseudomeningocele. The authors performed a retrospective chart review in order to evaluate the clinical outcomes of infants temporarily shunted for pseudomeningocele without encephalocele at our institution (The University of Illinois at Peoria/Illinois Neurological Institute) in the period from 2004 to 2012. The epidemiological characteristics, clinical management, and final outcomes of such subpopulation were compared with a control group which received temporary shunting for subdural hematomas (SDH) during the same period. Four patients (100% male) ranging in age from 8.9 to 27.1 months (mean = 13.88) with pseudomeningocele and 17 patients (64.7% male) ranging in age from 1.9 to 11.8 months (mean = 4.15) with SDH were identified. Although the initial management included sequential percutaneous subdural tapping in 82% of the patients, all children ultimately failed such strategy, requiring either subdural-peritoneal (81% of the cases) or subgaleal-peritoneal (19% of the cases) shunting. The mean implant duration was 201 days for the pseudomeningocele group and 384 days for the SDH one. Mean post-shunt hospitalization was 2 days for patients with pseudomeningocele and 4 days for patients with SDH. There was no statistical difference in terms of complications, length of hospitalization post-shunting, or clinical outcomes between the patients with pseudomeningocele and those with SDH. Temporary shunting of infants with pseudo-meningocele constitutes a viable therapeutic alternative with favorable clinical outcomes and a low risk of shunt dependency similar to those of children with SDH.
Slit ventricle syndrome and early-onset secondary craniosynostosis in an infant
Ryoo, Hyun Gee; Kim, Seung-Ki; Cheon, Jung-Eun; Lee, Ji Yeoun; Wang, Kyu-Chang; Phi, Ji Hoon
2014-01-01
Patient: Female, 14 months Final Diagnosis: Slit ventricle syndrome Symptoms: Hydrocephalus • lethargy and seizure • vomiting Medication: — Clinical Procedure: — Specialty: Pediatrics and Neonatology Objective: Challenging differential diagnosis Background: Shunt surgery is a common solution for hydrocephalus in infancy. Slit ventricle syndrome and secondary craniosynostosis are late-onset complications after shunt placement; these 2 conditions occasionally occur together. Case Report: We report a case of early-onset secondary craniosynostosis with slit ventricle syndrome after shunt surgery in an infant, which led to a catastrophic increase in intracranial pressure (ICP). A 4-month-old girl with a Dandy-Walker malformation underwent a ventriculoperitoneal shunt procedure. Her head circumference (HC) gradually decreased to approximately the 5th percentile for her age group after shunt surgery. Seven months later, she developed increased ICP symptoms and underwent a shunt revision with a diagnosis of shunt malfunction. Her symptoms were temporarily relieved, but she repeatedly visited the emergency room (ER) for the same symptoms and finally collapsed, with an abrupt increase in ICP, 3 months later. Further evaluation revealed the emergence of sagittal synostosis at 7 months after initial shunt surgery. After reviewing all clinical data, slit ventricle syndrome combined with secondary craniosynostosis was diagnosed. Emergent cranial expansion surgery with shunt revision was performed, and the increased ICP signs subsided in the following days. Conclusions: Clinical suspicion and long-term HC monitoring are important in the diagnosis of slit ventricle syndrome and secondary craniosynostosis after shunt surgery, even in infants and young children. PMID:24944727
Singhal, Ashish; Srivastava, Ajitabh; Goyal, Neerav; Vij, Vivek; Wadhawan, Manav; Bera, Motilal; Gupta, Subash
2009-12-01
Congenital portosystemic shunts are the anomalies in which the mesenteric venous drainage bypasses the liver and drains directly into the systemic circulation. This is a report of a rare case of LDLT in a four-yr old male child suffering with biliary atresia (post-failed Kasai procedure) associated with (i) a large congenital CEPSh from the spleno-mesentric confluence to the LHV, (ii) intrapulmonary shunts, (iii) perimembranous VSD. The left lobe graft was procured from the mother of the child. Recipient IVC and the shunt vessel were preserved during the hepatectomy, and the caval and shunt clamping were remarkably short while performing the HV and portal anastomosis. Post-operative course was uneventful; intrapulmonary shunts regressed within three months after transplantation and currently after 18 months following transplant child is doing well with normal liver functions. CEPSh has been extensively discussed and all the published cases of liver transplantation for CEPSh were reviewed.
Successful laparoscopic division of a patent ductus venosus: report of a case.
Hara, Yoshiaki; Sato, Yoshinobu; Yamamoto, Satoshi; Oya, Hiroshi; Igarashi, Masato; Abe, Satoshi; Kokai, Hidenaka; Miura, Kohei; Suda, Takeshi; Nomoto, Minoru; Aoyagi, Yutaka; Hatakeyama, Katsuyoshi
2013-04-01
Patent ductus venosus (PDV) is a rare condition of a congenital portosystemic shunt from the umbilical vein to the inferior vena cava. This report presents the case of an adult patient with PDV, who was successfully treated with laparoscopic shunt division. A 69-year-old male was referred with hepatic encephalopathy. Contrast-enhanced CT revealed a large connection between the left portal vein and the inferior vena cava, which was diagnosed as PDV. The safety of a shunt disconnection was confirmed using a temporary balloon occlusion test for the shunt, and the shunt division was performed laparoscopically. The shunt was carefully separated from the liver parenchyma with relative ease, and then divided using a vascular stapler. Portal flow was markedly increased after the operation, and the liver function of the patient improved over the 3-month period after surgery. Although careful interventional evaluation for portal flow is absolutely imperative prior to surgery, a minimally invasive laparoscopic approach can be safely used for treating PDV.
Chan, Andrew K; Birk, Harjus S; Winkler, Ethan A; Viner, Jennifer A; Taylor, Jennie W; McDermott, Michael W
2016-07-07
The Optune® transducer array (Novocure Ltd., Haifa, Israel) is an FDA-approved noninvasive regional therapy that aims to inhibit the growth of glioblastoma multiforme (GBM) cells via utilization of alternating electric fields. Some patients with GBM may develop hydrocephalus and benefit from subsequent shunt placement, but special attention must be paid to patients in whom programmable valves are utilized, given the potential effect of the magnetic fields on valve settings. We present the first case report illustrating the stability of programmable shunt valve settings in a neurosurgical patient undergoing therapy with the Optune device. In this study, shunt valve settings were stable over a period of five days despite Optune therapy. This is reassuring for patients with GBM who require simultaneous treatment with both the Optune device and a programmable shunt system.
Small bowel perforation: a rare complication of ventriculoperitoneal shunt placement
Bourm, Kelsey; Pfeifer, Cory; Zarchan, Adam
2016-01-01
Small bowel perforation is a rare complication of ventriculoperitoneal (VP) shunt placement. When seen, it most commonly affects the stomach or colon. We describe a case and image findings of an 8-year-old female who presented with sepsis and erosion of the VP shunt into the small bowel. The imaging findings were confirmed surgically. We also provide an overview of the current literature discussing previously reported cases, clinical features, and treatment. PMID:27761183
Long-term results of small-diameter proximal splenorenal venous shunt: A retrospective study
Chen, Hao; Yang, Wei-Ping; Yan, Ji-Qi; Li, Qin-Yu; Ma, Di; Li, Hong-Wei
2011-01-01
AIM: To investigate recurrent variceal hemorrhage and long-term survival rates of patients treated with partial proximal splenorenal venous shunt. METHODS: Patients with variceal hemorrhage who were treated with small-diameter proximal splenorenal venous shunt in Ruijin Hospital between 1996 and 2009 were included in this study. Shunt diameter was determined before operation using Duplex Doppler ultrasonography. Peri-operative and long-term results in term of rehemorrhage, encephalopathy and mortality were followed up. RESULTS: Ninety-eight patients with Child A and B variceal hemorrhage received small-diameter proximal splenorenal venous shunt with a diameter of 7-10 mm. After operation, the patients’ mean free portal pressure (P < 0.01) and the flow rate of main portal vein (P < 0.01) decreased significantly compared with that before operation. The rates of rebleeding and mortality were 6.12% (6 cases) and 2.04% (2 cases), respectively. Ninety-one patients were followed up for 7 mo-14 years (median, 48.57 mo). Long-term rates of rehemorrhage and encephalopathy were 4.40% (4 cases) and 3.30% (3 cases), respectively. Thirteen patients (14.29%) died mainly due to progressive hepatic dysfunction. Five- and ten-year survival rates were 82.12% and 71.24%, respectively. CONCLUSION: Small-diameter proximal splenorenal venous shunt affords protection against variceal rehemorrhage with a low occurrence of encephalopathy in patients with normal liver function. PMID:21876638
Awad, Nadia; Choudry, Rashad; Durinka, Joel; Prabhu, Aparna; Dissin, Jonathan
2013-02-01
Although intraarterial shunting during carotid endarterectomy is a well-defined practice, its use remains controversial. Complication rates associated with shunt placement remain low, but may be underreported. When complications secondary to routine intraarterial shunting occur, they can cause significant morbidity or even mortality, emphasizing the importance of meticulous technique to prevent adverse outcomes. We report a case of internal carotid artery dissection and pseuedoaneurysm due to the technical failure of a safety device of an intraarterial shunt used during carotid endarterectomy.
Tanito, Masaki; Sano, Ichiya; Ohira, Akihiro
2015-01-08
We report a case of Ex-PRESS miniature glaucoma shunt obstruction resulting from progressive iris synechial formation after transient anterior chamber shallowing. A 68-year-old woman with pseudoexfoliation glaucoma in her right eye underwent filtration surgery with implantation of the Ex-PPESS shunt (model P-50, Alcon Japan, Tokyo, Japan) in combination with intra-surgical 0.04% mitomycin C use. After the anterior chamber injection of viscoelastic material and 100% sulfur hexafluoride gas for treatment of early postoperative over filtration, the intraocular pressure (IOP) was controlled between 9 and 12 mmHg. On postoperative day 121, gonioscopy showed that synechial formation around the shunt obstructed the axial port leaving the relief port opened. On postoperative day 274, the intraocular pressure increased to 40 mmHg and synechiae obstructed both the axial and relief ports. Dispersion of iris tissue by neodymium:yttrium-aluminium-garnet (Nd:YAG) laser (2 mJ, one shot to each port) opened both ports and immediately lowered the IOP, leaving peripheral anterior synechiae around the shunt. Up to postoperative day 400, the IOP was controlled between 13 and 15 mmHg, and the cystic bleb was maintained. The synechiae formed gradually extends around the shunt's shaft and can result in later external obstruction of the relief port. The current case requires further follow-up since synechiae remaining around the shaft can cause future obstruction. We emphasize the fact that, if the iris synechiae to the shunt once formed, it can progress and obstruct the shunt ports later.
Aguas, Jesús; Rodrigo, Victor; Estupiñan, Francisco; Nogues, Pere; Villalba, Gloria; Villagrasa, Javier; Caral, Luis
2013-01-01
Normal pressure hydrocephalus (NPH) is a clinical entity frequently managed by means of a cerebrospinal fluid shunt. Hydrodynamic hypotheses consider hydrostatic pressure (as well as height) a very important variable for shunt system function. However, we did not find empirical studies supporting the influence of height on clinical response in the literature. Our objective was to study the prognostic value of height, as a variable related to hydrostatic pressure, when an identical shunt system is used. A prospective series of 61 idiopathic NPH cases was analyzed. All cases were shunted by means of a ventricle-peritoneal system with a 100mmH2O opening pressure valve. Anthropometric, clinical, radiological and pressure variables were registered, as well as delay for treatment, improvement and complications. 78.7% of cases improved after shunting. This group of patients was significantly taller (P=.005) than the group without response (median value 165cm versus 152cm). There was also a significant correlation between height and ventricular size decrease after the shunt. In our series opening valve pressure was a constant (100mmHg) and we could consequently focus on the effect of hydrostatic pressure (height). Moreover, we found a positive predictive value for taller patients, probably because we had selected an opening pressure especially suitable for them. Current gravitational valve shunt systems also recommend considering patient height when customising the system. Our study empirically supports this idea. Copyright © 2012 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.
[Small-diameter portosystemic shunts: indications and limitations].
Angel Mercado, M; Granados-García, J; Barradas, F; Chan, C; Contreras, J L; Orozco, H; Angel-Mercado, M
1998-01-01
Low diameter porto-systemic shunts for the treatment of portal hypertension bleeding have emerged as a consequence of the technical development of vascular grafts (PTFE) that allow the use of a narrow lumen. The experience with this kind of operation at the Instituto Nacional de la Nutrición Salvador Zubirán, Mexico City during a 6-year period is reported. There were twenty-seven patients with good liver function (Child-Pugh A-B) were operated or electively, average Age 47.5 years (range 17-71), twenty three patients with liver cirrhosis, one with portal fibrosis and three with idiopathic portal hypertension. Operative mortality: 4%. Rebleeding: 14%. Postoperative encephalopathy was observed in 14 of 27, three of them being grade III-IV (11%). In the remaining 11 cases, it was mild and easily controlled. Postoperative angiography showed shunt patency in 81% of the cases; in 33% of the cases, portal vein diameter reduction was shown, as well as two cases with portal vein thrombosis. In 77% of the cases, adequate postoperative quality of life was observed. Survival (Kaplan-Meier): 86% at 12 months and 56% at 60 months. These kinds of shunts are a good alternate choice for patients considered for surgery, in which other portal blood flow preserving procedures (selective shunts, devascularization with transection) are not feasible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaba, Ron C., E-mail: rgaba@uic.edu; VanMiddlesworth, Kyle A.
2012-12-15
Yttrium-90 ({sup 90}Y) radioembolization represents an emerging transcatheter treatment option for the management of hepatocellular carcinoma (HCC). Elevation of the hepatopulmonary shunt fraction risks nontarget radiation to the lungs and may limit the use of {sup 90}Y therapy in patients with locally advanced disease with vascular invasion, who often demonstrate increased shunting. We present two cases in which patients with HCC and portal vein invasion resulting in elevated hepatopulmonary shunt fractions underwent chemoembolic shunt closure to allow safe {sup 90}Y radioembolization. Both patients demonstrated excellent tumor response and patient survival. On this basis, we propose a role for chemoembolic reductionmore » of the lung shunt fraction before {sup 90}Y radioembolization in patients with extensive tumor-related hepatopulmonary shunting.« less
Dandy-Walker Malformation: A Clinical and Surgical Outcome Analysis.
Bokhari, Iram; Rehman, Lal; Hassan, Sher; Hashim, M Sattar
2015-06-01
To determine the clinical presentations, complications and mortality in patients with Dandy-Walker Malformation (DWM) after surgery i.e., shunt with y-connector. Case series. Neurosurgery Ward, JPMC, Karachi, from January 2009 to December 2013. Cases of DWM, with associated hydrocephalus, further confirmed on CT scan of brain, were admitted through OPD. Those who were previously operated, those with other associated co-morbid or anomalies were excluded from this study. Combined drainage of the ventricular system and posterior fossa cyst, via dual shunt i.e. cystoperitoneal and ventriculoperitoneal shunt with y-connector was performed in all patients. Complications and mortality after surgical intervention in these patients were noted upto one month after surgery. The data analysis for descriptive statistics was done on SPSS version 20. In this study of 70 patients, majority of the patients were female aged between 1 - 2 years. Hydrocephalus was the predominant symptom as being present in all patients, followed by cerebellar signs in 60 (86%), and other in 5 (7.14%) patients. Complications of surgery were infection and shunt fracture dislocation in 7 (10%) each, malpositioning and shunt blockage in 6 (8.5%) each within one month of surgery, intracranial haemorrhage in 5 (7.14%) patients. Only one patient (1.42%) expired after surgical intervention. In DWM, the commonest presentation is that of hydrocephalus. Shunt malfunction and infection are the commonest complication after shunting. Dual shunt with y-connector has the lowest mortality when compared with other methods for treatment of shunt with y-connector.
Bret, P; Chazal, J
1995-12-01
"Normal pressure" hydrocephalus (NPH) is generally considered to be a disorder of the adult and geriatric population. Only a few reports have described the possible occurrence of this condition in children. A series of 16 patients aged less than 20 years forms the basis of the present report. Among these 16 patients, 11 had a clearly identified etiologic factor and 7 had had a shunt previously implanted. The majority of patients exhibited at least two elements of the adult's triad of psychomotor retardation (14 cases) and/or psychotic-like symptoms (4 cases), gait anomalies (8 cases), and sphincter disturbances (3 cases). Six patients had their intracranial pressure (ICP) monitored. ICP values were estimated to be within the normal limits for age. All the 16 patients underwent shunting or shunt revision. Surgical results were as follows (mean follow-up 20 +/- 17.2 months): a good response to shunting was obtained in 12 cases ("cured": 5, improved: 7), while the other 4 patients failed to improve. It seems likely that associated parenchymal disorders have played a major role in therapeutic failures. In children showing ventricular dilation on computed tomographic (CT) analysis and a clinical picture of subtle psychomotor deterioration, it may be difficult to distinguish an active disorder of the CSF dynamics from "arrested hydrocephalus." Since intracranial manometry cannot be undertaken as a routine procedure, less invasive methods such as cerebrospinal fluid (CSF) tap test, psychometric, or urodynamic tests deserve special attention as reliable predictors of outcome after shunting. Because most patients undergo shunting without prior assessment of their CSF pressure, the term "chronic hydrocephalus" is proposed as an alternative designation to "NPH," since there is little argument for maintaining an instrumentally based definition of the syndrome.
[Octreotide treatment for postoperative chylous ascites in an adult].
Senosiain Lalastra, Carla; Martínez González, Javier; Mesonero Gismero, Francisco; Moreira Vicente, Víctor
2012-10-01
Chylous ascites is infequent after abdominal surgery. We describe the case of a 43-year-old man with portal cavernomatosis who underwent surgery to insert a splenorenal shunt, which was not placed due to the absence of signs of portal hypertension. On postoperative day 20, the patient developed abdominal distension and mild dyspnea and was diagnosed with chylous ascites, which was related to the surgery. The patient was initially treated with diet and diuretics, with no clinical response, and consequently octreotide therapy was started. Four days later, the ascites was almost resolved and an ultrasound scan at 4 months showed its complete disappearance. This article demonstrates the effectiveness of octreotide in the treatment of postsurgical chylous ascites. Copyright © 2012 Elsevier España, S.L. and AEEH y AEG. All rights reserved.
Leal, N; López Santamaría, M; Gámez, M; Murcia, J; Andolfi, G; Berrocal, T; Frauca, E; Jara, P; Tovar, J
2002-07-01
Presinusoidal portal hypertension (PPH) in children evaluates without functional hepatic damage, and with the time, trends to compensate through the creation of spontaneous portosystemic shunts. Nevertheless, some patients suffer episodes of gastrointestinal bleeding (GIB) that because of its frequency or severity, force to propose the change of surgical treatment. To evaluate the results of the mesocaval shunt (MCS) with autologous jugular vein in children with PPH. Among the 32 children with PPH treated in our Hospital in the last 7 years, 10 had episodes of GIB that forced to perform a surgical shunt. The types of shunt were distal splenorenal in 3 patients and mesocaval in 7. These 7 cases are the material of this study. The origin of the PPH was a cavernomatosis transformation of the portal vein in 6 cases and a congenital hepatic fibrosis in 1. Before the surgery the average number of episodes of GIB was 9 (range 2-15); all the patients needed transfusion of blood products and variceal sclerosis. In 2 cases a tamponade with the Sengtaken balloon was required and 5 patients were treated with somatostatin and propranolol. The Doppler ultrasounds revealed and intense hepatofugal collateral circulation in all the cases. The initial flow through the shunt was adequate in all the patients except one who required a percutaneous balloon dilatation. Only this patient has suffered an episode of GIB. The hyperesplenism signs disappeared or improved in all the seven cases and the collateral circulation was significantly reduced. The pressure in the splenic territory decreased around 50% in the 4 patients that was measured. There were no cases of encephalopasty and only one child with congenital hepatic fibrosis shows signs of mild hepatic disfunction. The medium follow up post-shunt is 32 months (range 8 m-6 years). The MCS prevents the GIB in the PPH not responsive to the conservative treatment; its effectiveness is related with an adequate permeability though the graft and at least in the cases with portal cavernomatosis (the most frequent in children) doesn't produce hepatic dysfunction. Doppler ultrasounds give a very precise information about the post-surgical situation and are an excellent method of follow up.
Single Center Experience with the AngioVac Aspiration System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salsamendi, Jason, E-mail: jsalsamendi@med.miami.edu; Doshi, Mehul, E-mail: mdoshi@med.miami.edu; Bhatia, Shivank, E-mail: sbhatia1@med.miami.edu
2015-08-15
PurposeThe AngioVac catheter system is a mechanical suction device designed for removal of intravascular material using extracorporeal veno-venous bypass circuit. The purpose of this study is to present the outcomes in patients treated with the AngioVac aspiration system and to discuss its efficacy in different vascular beds.Materials and MethodsA retrospectively review was performed of seven patients treated with AngioVac between October 2013 and December 2014. In 6/7 cases, the AngioVac cannula was inserted percutaneously and the patient was placed on veno-venous bypass. In one of the cases, the cannula was inserted directly into the Fontan circuit after sternotomy and themore » patient was maintained on cardiopulmonary bypass. Thrombus location included iliocaval (2), SVC (1), pulmonary arteries (1), Fontan circuit and Glenn shunt with pulmonary artery extension (1), right atrium (1), and IVC with renal vein extension (1).ResultsThe majority of thrombus (50–95 %) was removed in 5/7 cases, and partial thrombus removal (<50 %) was confirmed in 2/7 cases. Mean follow-up was 205 days (range 64–403 days). All patients were alive at latest follow-up. Minor complications included three neck hematomas in two total patients. No major complications occurred.ConclusionAngioVac is a useful tool for acute thrombus removal in the large vessels. The setup and substantial cost may limit its application in straightforward cases. More studies are needed to establish the utility of AngioVac in treatment of intravascular and intracardiac material.« less
Nii, Akira; Takehara, Hiro-o; Kuyama, Hisako; Shimada, Mitsuo
2009-02-01
A congenital extrahepatic portosystemic shunt (CEPS) is a rare abnormality. The shunts are classified into 2 types. Of these, a type 2-shunt is a side-to-side one, which may be treated by a simple shunt division. The aim of this retrospective study was to clarify the effects of a surgical shunt division on 4 children with type 2-CEPS. Between June 2002 and June 2008, 4 children with type 2-CEPS underwent a surgical shunt division. Various clinical factors of each patient, including shunt types, shut ratios evaluated by portal scintigraphy using (123)I-iodoamphetamine, serum levels of ammonia and total bile acids before and after surgery were evaluated. Two children had a conventional open surgery and the other two had a laparoscopic surgery. The serum levels of ammonia as well as total bile acids of these children decreased significantly to the normal levels within a month after the surgical shunt divisions. All the children had a better clinical course. A shunt division, especially by laparoscopic surgery, is an effective therapy for type 2-CEPS. To the best of our knowledge by reviewing literatures, our cases are the youngest ones treated by laparoscopic shunt division.
Schödel, Petra; Proescholdt, Martin; Brawanski, Alexander; Bele, Sylvia; Schebesch, Karl-Michael
2012-04-01
Burr-hole trephine and insertion of an external ventricular drainage (EVD) is a common procedure in neurosurgical practice. In critically ill patients, the transport to the operating room, OR represents a major risk. Thus, the burr-hole trephine and implantation of an EVD is frequently performed on the Intensive Care Unit (ICU). Since 2004, we have applied two different procedures: the conventional method with a mechanical compressed air or an electric drill, and an alternative method with a manual twist drill, including fixation of the EVD in a skull screw (Bolt Kit, Raumedic AG, Germany). This study was designed to evaluate the outcome of both surgical procedures. In this retrospective analysis we included 166 consecutive patients with acute hydrocephalus due to intracranial hemorrhage that had been operated at our neurosurgical ICU in a six years interval. We reviewed the charts for gender and age, kind of surgical procedure, cerebrospinal fluid (CSF)-infections, duration of drainage, attempts of insertions, wound infections, misplacement rate, post-surgical hemorrhages, revisions, comorbidities and shunt-dependency. In 122 patients we applied the Bolt Kit System, in 44 patients the conventional method was performed. We found a significantly lower rate of CSF-infections and significantly fewer attempts of insertions in the Bolt Kit group (p = 0.002 and p = 0.001, respectively). The rate of wound infections, misplacement, revisions, shunt-dependency and the post-surgical hemorrhages did not differ significantly. Our data indicate that the manual drill and the skull screw are safe and feasible tools in the treatment of acute hydrocephalus. Presumably, the direct skin contact is causative for the higher rate of CSF-infections when the conventional method is performed. The skull screw guides the EVD into the ventricle without skin contact. The lower number of insertions needed may be due to the fact that the skull screw allows just one trajectory for the insertion of the EVD.
Congenital multiple intrahepatic portosystemic shunt: an autopsy case
Takahashi, Seishiro; Yoshida, Eriko; Sakanishi, Yasushi; Tohyama, Norihiro; Ayhan, Ayse; Ogawa, Hiroshi
2014-01-01
Multiple intrahepatic portosystemic shunt (IPSS) without portal hypertension, now thought to be congenital in origin, is very rare. The presence of IPSS, unlike other congenital diseases, may not be recognized for several decades due to the time it takes to develop hepatic encephalopathy. In this article, we report an autopsy case of an 80-year-old Japanese woman with a one-month history of hyperammonemic encephalopathy. Radiological examination of the liver revealed some abnormal connections between the branches of the portal veins and the hepatic veins, but the cause of the aberrant blood flow was not found. The cause of death was extensive cerebral infarction due to thromboembolism. At postmortem examination, multiple anomalous blood vessels were identified histologically in both lobes of the non-cirrhotic liver. In comparison with the few similar cases existing in the literature, this case should be diagnosed as congenital IPSS. To our knowledge, this is the first detailed histological study of IPSS, as several autopsy case reports exist but their histological descriptions are poor. Unlike past reports, the shunt vessels were accompanied by clear elastic lamellae that were microscopically observed. In addition to shunt vessels, septal fibrosis, disorder of hepatic acinar structure, and sinusoidal dilatation and capillarization were observed in the liver. We suggest that these histological modifications observed in the circumference of the shunt vessels acted as secondary regenerative/hyperplastic changes based on blood-flow imbalance caused by the IPSS. PMID:24427367
Congenital multiple intrahepatic portosystemic shunt: an autopsy case.
Takahashi, Seishiro; Yoshida, Eriko; Sakanishi, Yasushi; Tohyama, Norihiro; Ayhan, Ayse; Ogawa, Hiroshi
2014-01-01
Multiple intrahepatic portosystemic shunt (IPSS) without portal hypertension, now thought to be congenital in origin, is very rare. The presence of IPSS, unlike other congenital diseases, may not be recognized for several decades due to the time it takes to develop hepatic encephalopathy. In this article, we report an autopsy case of an 80-year-old Japanese woman with a one-month history of hyperammonemic encephalopathy. Radiological examination of the liver revealed some abnormal connections between the branches of the portal veins and the hepatic veins, but the cause of the aberrant blood flow was not found. The cause of death was extensive cerebral infarction due to thromboembolism. At postmortem examination, multiple anomalous blood vessels were identified histologically in both lobes of the non-cirrhotic liver. In comparison with the few similar cases existing in the literature, this case should be diagnosed as congenital IPSS. To our knowledge, this is the first detailed histological study of IPSS, as several autopsy case reports exist but their histological descriptions are poor. Unlike past reports, the shunt vessels were accompanied by clear elastic lamellae that were microscopically observed. In addition to shunt vessels, septal fibrosis, disorder of hepatic acinar structure, and sinusoidal dilatation and capillarization were observed in the liver. We suggest that these histological modifications observed in the circumference of the shunt vessels acted as secondary regenerative/hyperplastic changes based on blood-flow imbalance caused by the IPSS.
In vivo analysis of conjunctiva in gold micro shunt implantation for glaucoma.
Mastropasqua, Leonardo; Agnifili, Luca; Ciancaglini, Marco; Nubile, Mario; Carpineto, Paolo; Fasanella, Vincenzo; Figus, Michele; Lazzeri, Stefano; Nardi, Marco
2010-12-01
To describe the conjunctival epithelial features seen with in vivo confocal microscopy (IVCM) after gold micro shunt (GMS) implantation in the suprachoroidal space, in patients with uncontrolled glaucoma. This was an observational case series study. Fourteen eyes of 14 consecutive glaucomatous patients with a history of multiple failed incisional surgeries followed by GMS implantation were evaluated with a digital confocal laser-scanning microscope (HRT II Rostock Cornea Module). Patients were divided into two groups: successful implantations (Group 1: eight patients, eight eyes), defined as a one-third reduction in preoperative intraocular pressure (IOP) with or without antiglaucoma medications and failed implantations (Group 2: six patients, six eyes) as a less than one-third reduction in preoperative IOP with maximal tolerated medical therapy. The examination was performed from 3 to 20 months (mean 15.4±5.4) postoperatively. Conjunctival mean microcyst density (MMD: cysts/mm(2)) and mean microcyst area (MMA: μm(2)) were the main outcome measurements. The mean postoperative IOP was statistically different between the two groups (p<0.05), with the values of 14.3±2.77 and 32.3±8.01 mm Hg in Groups 1 and 2, respectively. When comparing successful with failed implantation, the IVCM analysis showed a greater MMD (p<0.01) and MMA (p<0.01). Clinical evidence of filtering bleb was not found in any of the patients. Successful GMS implantation significantly increased conjunctival microcysts density and surface at the site of the device insertion. These findings suggest that the enhancement of the aqueous filtration across the sclera may be one of the possible outflow pathways exploited by the shunt.
Xie, Zhiyi; Hu, Xin; Zan, Xin; Lin, Sen; Li, Hao; You, Chao
2017-10-01
Hydrocephalus is a well-recognized complication after aneurysmal subarachnoid hemorrhage (aSAH). This study aimed to identify predictors for shunt-dependent hydrocephalus (SDHC) after aSAH via a systematic review and meta-analysis. A systematic search was conducted using the Embase, MEDLINE, and Web of Science databases for studies pertaining to aSAH and SDHC. Risk factors were assessed by meta-analysis when they were reported by at least 2 studies. The results were presented as odd ratios or risk ratios according to the study design with the corresponding 95% confidence intervals (CI). Twenty-five studies were included. In primary analysis of 14 potential risk factors, 12 were identified as predictors of SDHC after aSAH including age ≥50 years, female gender, high Hunt-Hess grade, Glasgow Coma Scale ≤8, Fisher grade ≥3, acute hydrocephalus, external ventricular drainage insertion, intraventricular hemorrhage, postcirculation aneurysm, anterior communicating artery aneurysm, meningitis, and rebleeding. The meta-analysis based on cohort studies found a significantly increased risk for SDHC in patients with aSAH treated by coiling (risk ratio, 1.16; 95% CI, 1.05-1.29), while the meta-analysis based on case-controlled studies failed to replicate this finding (odds ratio, 1.27; 95% CI, 0.95-1.71). Several new predictors of SDHC after aSAH were identified that may assist with the early recognition and prevention of SDHC. The controversial evidence found in this study was insufficient to support the potential of neurosurgical clipping for reducing the risk of shunt dependency. Further well-designed studies are warranted to explore the effect of treatment modality on SDHC risk. Copyright © 2017 Elsevier Inc. All rights reserved.
[Feto-amniotic shunting for lower urinary tract obstruction (LUTO)--a case report].
Lautmann, K; Staboulidou, I; Schippert, C; Hillemanns, P; Wüstemann, M
2007-12-01
Posterior urethral valves are the main cause of fetal lower urinary tract obstruction (LUTO) with typical sonographic signs like urinary tract dilatation and reduction of amniotic fluid. LUTO is associated with a high rate of perinatal mortality and is the main cause of kidney failure in early childhood. In such cases vesico-amniotic shunting is a common but risky procedure of fetal surgery to prevent anhydramnion and lethal lung hypoplasia. This case report demonstrates that lung hypoplasia can be prevented by vesico-amniotic shunting of the fetal megacytis in the 23rd week of gestation in a fetus with lower urinary tract obstruction and anhydramnion. The prenatal measured concentration of cystatin C in the fetal urine correlated with the postnatal impaired kidney function. The indication and therapeutic benefit of vesico-amniotic shunting remain controversially discussed in the literature because until today there is no evidence for a reduction in perinatal or long-term morbidity due to early fetal kidney damage. The earlier ultrasound detection of LUTO during the first trimester of pregnancy proposes the possibility of earlier intervention and protection of nephrogenesis. First case studies about first trimester vesico-amniotic shunting have been published; the influence on the postnatal kidney function merits further well-structured investigation.
Guneyli, Serkan; Cinar, Celal; Bozkaya, Halil; Parildar, Mustafa; Oran, Ismail; Akin, Yigit
2012-12-01
Congenital portosystemic venous shunt is extremely rare and should be treated. Advances in treatment techniques allow for patients to be treated safely. We present a 9-year-old boy with a large congenital portosystemic venous shunt. The shunt was occluded interventionally with the Amplatzer vascular plug II. Our case was unique with its clinical manifestation, the use of a 22-mm Amplatzer vascular plug II, and the presence of the patient's 1-year follow-up.
Davidson, Anders J; Neff, Lucas P; Grayson, J Kevin; Clement, Nathan F; DeSoucy, Erik S; Simon Logan, Meryl A; Abbot, Christopher M; Sampson, James B; Williams, Timothy K
2017-09-01
The small diameter of temporary vascular shunts for vascular trauma management may restrict flow and result in ischemia or early thrombosis. We have previously reported a clinical experience with direct, open surgical reconstruction using expandable polytetrafluoroethylene stent grafts to create a "sutureless" anastomosis as an alternative to standard temporary vascular shunts. We sought to characterize patency and flow characteristics of these grafts compared with standard shunts in a survival model of porcine vascular injury. Twelve Yorkshire-cross swine received a 2-cm-long near-circumferential defect in the bilateral iliac arteries. A 14 Fr Argyle shunt was inserted into one randomly assigned artery, with a self-expanding expandable polytetrafluoroethylene stent deployed in the other. At 72 hours, conduit patency was evaluated by angiography. Arterial flow measurements were obtained at baseline, immediately after intervention, and after 72 hours via direct measurement with perivascular flow meters. Blood pressure proximal and distal to the conduits and arterial samples for histopathology were obtained during the terminal procedure. Angiography revealed no difference in patency at 72 hours (p = 1.0). While there was no difference in baseline arterial flow between arteries (p = 0.63), the stent grafts demonstrated significantly improved blood flow compared with shunts both immediately after intervention (390 ± 36 mL/min vs. 265 ± 25 mL/min, p = 0.002) and at 72 hours (261 ± 29 mL/min vs. 170 ± 36 mL/min, p = 0.005). The pressure gradient across the shunts was greater than that of the stent grafts (11.5 mm Hg [interquartile range, 3-19 mm Hg] vs. 3 mm Hg [interquartile range, 3-5 mm Hg], p = 0.013). The speed of deployment was similar between the two devices. Open "sutureless" direct site repair using commercially available stent grafts to treat vascular injury is a technically feasible strategy for damage control management of peripheral vascular injury and offers increased blood flow when compared with temporary shunts. Furthermore, stent grafts may offer improved durability to extend the window until definitive vascular repair. The combination of these traits may improve outcomes after vascular injury. Epidemiologic/Prognostic, level III.
Yazal Erdem, Arzu; Emir, Suna; Demir, Haci A; Özyörük, Derya; Çetin, İlker; Turan, Aynur; Karakuş, Esra
2017-01-01
Congenital portosystemic shunts are rare vascular malformations that lead to several complications including liver tumors, pulmonary hypertension, and metabolic encephalopathy. We describe a rare case of a 17-year-old girl with an extrahepatic portosystemic shunt presenting recurrent syncope episodes and a liver mass mimicking hepatocellulary carcinoma.
Pruritus possibly associated with a portosystemic shunt in a bichon frise puppy
Waisglass, Stephen E.; Gillick, Avery; Cockshutt, Joanne; Hall, Jan A.
2006-01-01
A bichon frise puppy was presented with generalized pruritus. At 22 weeks, a portosystemic shunt was diagnosed. Correction of the shunt led to resolution of the pruritus. Pruritus associated with hepatobiliary disease is well documented in humans; this case suggests that hepatobiliary disease may be associated with pruritus in dogs. PMID:17147142
Armored brain: A case report and review of the literature
Petraglia, Anthony L.; Moravan, Michael J.; Jahromi, Babak S.
2011-01-01
Background: Calcified chronic subdural hematomas occur infrequently. When the calcifications are extensive and bilateral, the condition is termed “armored brain”. We describe a case of “armored brain” incidentally discovered in an adult presenting with abdominal pain and mild headaches, long after initial placement of a ventriculo-peritoneal (VP) shunt. Case Description: A 38-year-old woman, treated at infancy with a VP shunt, presented with a 2-month history of abdominal pain associated with nausea and chills. She was neurologically intact on exam. An abdominal computed tomography (CT) scan demonstrated a rim-enhancing loculated fluid collection surrounding the patient's distal VP shunt catheter tip. As a part of her initial work-up, she received a head CT to evaluate the proximal VP shunt, which demonstrated large bilateral chronic subdural hematomas with heavily calcified walls. She was eventually taken to the operating room (OR) for replacement of the distal catheter. It was felt that her acute clinical presentation was unrelated to the bilateral, calcified subdural hematomas and thus the decision was made to manage them conservatively. Conclusions: This rare complication of chronic shunting for hydrocephalus is sometimes referred to as armored brain. Surgery for armored brain is infrequently indicated and beneficial in only small subgroup of patients, with management guided by clinical presentation. Our patient fully recovered after shunt revision alone. PMID:21918735
A High Isolation Series-Shunt RF MEMS Switch
Yu, Yuan-Wei; Zhu, Jian; Jia, Shi-Xing; Shi, Yi
2009-01-01
This paper presents a wide band compact high isolation microelectromechanical systems (MEMS) switch implemented on a coplanar waveguide (CPW) with three ohmic switch cells, which is based on the series-shunt switch design. The ohmic switch shows a low intrinsic loss of 0.1 dB and an isolation of 24.8 dB at 6 GHz. The measured average pull-in voltage is 28 V and switching time is 47 μs. In order to shorten design period of the high isolation switch, a structure-based small-signal model for the 3-port ohmic MEMS switch is developed and parameters are extracted from the measured results. Then a high isolation switch has been developed where each 3-port ohmic MEMS switch is closely located. The agreement of the measured and modeled radio frequency (RF) performance demonstrates the validity of the electrical equivalent model. Measurements of the series-shunt switch indicate an outstanding isolation of more than 40 dB and a low insertion loss of 0.35 dB from DC to 12 GHz with total chip size of 1 mm × 1.2 mm. PMID:22408535
[Selective portal-systemic shunts for bleeding portal hypertension].
Orozco, H; Mercado, M A; Takahashi, T; García-Tsao, G; Guevara, L; Hernandez-Ortiz, J; Tielve, M
1990-07-01
At the beginning of the seventies, we began to perform regularly selective shunts for the treatment of portal hypertension. In a 15 year period, 177 patients (155 with liver cirrhosis) were operated with three kinds of selective shunts: 128 with a Warren shunt, 29 with an end to end renosplenic shunt and 20 with a splenocaval shunt. 167 cases were operated in an elective fashion. The 15 years global operative mortality, was 14.4%. Operative mortality of the Child A patients, was 11.6%. Survival for the Child A group was 74.6% at 1 year, 68.2% at 5 years and 64.6% at 15 years. Incapacitating encephalopathy was observed in 6.9%, rebleeding 6.2% and shunt thrombosis in 6.2%. Portal vein alterations in the postoperative period were observed: in 13.3% a reduction in diameter ocurred and in 20.5%, thrombosis was recorded. It is concluded that when feasible, the selective shunts are the treatment of choice for portal hypertension in those patients with good liver function.
Multi-resonant electromagnetic shunt in base isolation for vibration damping and energy harvesting
NASA Astrophysics Data System (ADS)
Pei, Yalu; Liu, Yilun; Zuo, Lei
2018-06-01
This paper investigates multi-resonant electromagnetic shunts applied to base isolation for dual-function vibration damping and energy harvesting. Two multi-mode shunt circuit configurations, namely parallel and series, are proposed and optimized based on the H2 criteria. The root-mean-square (RMS) value of the relative displacement between the base and the primary structure is minimized. Practically, this will improve the safety of base-isolated buildings subjected the broad bandwidth ground acceleration. Case studies of a base-isolated building are conducted in both the frequency and time domains to investigate the effectiveness of multi-resonant electromagnetic shunts under recorded earthquake signals. It shows that both multi-mode shunt circuits outperform traditional single mode shunt circuits by suppressing the first and the second vibration modes simultaneously. Moreover, for the same stiffness ratio, the parallel shunt circuit is more effective at harvesting energy and suppressing vibration, and can more robustly handle parameter mistuning than the series shunt circuit. Furthermore, this paper discusses experimental validation of the effectiveness of multi-resonant electromagnetic shunts for vibration damping and energy harvesting on a scaled-down base isolation system.
Ringe, K; Schirg, E; Melter, M; Flemming, P; Ringe, B; Becker, T; Galanski, M
2008-05-01
The Abernethy malformation is a rare congenital portosystemic shunt in which the blood directly drains into the systemic vein bypassing the liver either through a complete (type 1) or a partial shunt (type 2). The diagnosis is most frequently established primarily with ultrasound. CT and MRI are used for further classification of the shunt and assessment of accompanying liver tumors and malformations. There is a wide spectrum of therapeutic options ranging from noninvasive conservative treatment to liver transplantation. The main prognostic factors are the occurrence of concomitant hepatic neoplasms and hepatic encephalopathy. We report two cases diagnosed with a type 1 shunt, hepatic encephalopathy, and associated liver tumors who underwent successful liver transplantation after having considered all therapeutic options.
Kilby, Mark; Khan, Khalid; Morris, Katie; Daniels, Jane; Gray, Richard; Magill, Laura; Martin, Bill; Thompson, Peter; Alfirevic, Zarko; Kenny, Simon; Bower, Sarah; Sturgiss, Stephen; Anumba, Dilly; Mason, Gerald; Tydeman, Graham; Soothill, Peter; Brackley, Karen; Loughna, Pamela; Cameron, Alan; Kumar, Sailesh; Bullen, Phil
2007-07-01
The primary objective is to determine whether intrauterine vesicoamniotic shunting for fetal bladder outflow obstruction, compared with conservative, noninterventional care, improves prenatal and perinatal mortality and renal function. The secondary objectives are to determine if shunting for fetal bladder outflow obstruction improves perinatal morbidity, to determine if improvement in outcomes is related to prognostic assessment at diagnosis and, if possible, derive a prognostic risk index and to determine the safety and long-term efficacy of shunting. A multicentre randomised controlled trial (RCT). Fetal medicine units. Pregnant women with singleton, male fetus with isolated lower urinary tract obstruction (LUTO). Following ultrasound diagnosis of LUTO in a male fetus and exclusion of other structural and chromosomal anomalies, participation in the trial will be discussed with the mother and written information given. Consent for participation in the trial will be taken and the mother randomised via the internet to either insertion of a vesicoamniotic shunt or expectant management. During pregnancy, both groups will be followed with regular ultrasound scans looking at viability, renal measurements and amniotic fluid volume. Following delivery, babies will be followed up by paediatric nephrologists/urologists at 4-6 weeks, 12 months and 3 and 5 years to assess renal function via serum creatinine, renal ultrasound and need for dialysis/transplant. The main outcome measures will be perinatal mortality rates and renal function at 4-6 weeks and 12 months measured via serum creatinine, renal ultrasound and need for dialysis/transplant. Wellbeing of Women. ESTIMATED COMPLETION DATE: September 2010. TRIAL ALGORITHM: [flowchart: see text].
Arterial and venous embolization: Declotting of dialysis shunts by direct injection of streptokinase
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zeit, R.M.
1986-06-01
During the past 33 months, thrombolysis of 79 clotted hemodialysis shunts was attempted by injecting small quantities of dilute streptokinase solution directly into the clotted shunt, followed by massage of the clot. Embolization of clot fragments in six of 79 cases (7.6%) was demonstrated angiographically. In four of the six cases embolization involved the brachial artery or its branches. In one case embolization involved an arm vein, and in one case embolization involved both the bracial artery and axillary vein. All patients remained asymptomatic, and repeat angiographic study, usually performed the following day, showed resolution of the emboli in fourmore » of five cases. The incidence of embolization in direct-injection thrombolysis reported in this study appears to be comparable to that reported in studies using the streptokinase infusion technique.« less
Patency of cavopulmonary connection studied by single phase electron beam computed tomography.
Choi, Byoung Wook; Park, Young Hwan; Lee, Jong Kyun; Kim, Dong Joon; Kim, Min Jung; Choe, Kyu Ok
2003-10-01
The shunt patency and anatomic alteration of central PA after cavopulmonary connection was assessed by one phase electron-beam computed tomography (EBCT) METHODS: Thirteen patients that received a bi-directional cavo-pulmonary shunt (BCPS, n = 7) or total cavo-pulmonary connection (TCPC, n = 6) were included. The patency of the shunt and the anatomy of intra-pericardial PA were evaluated by EBCT, and compared by angiography and echocardiography. EBCT accurately evaluated shunt patency and the anatomy of the intra-pericardial PA, except for the incorrect diagnosis of SVC-PA shunt patency and peripheral pulmonary stenosis in two TCPC patients. Both of these patients had bilateral SVC and received either bilateral BCPS or ligation of the left SVC respectively. The baffle between the IVC and PA was partly opacified through a fenestration of the baffle, but was not opacified in two patients without fenestration. EBCT accurately evaluated shunt patency and the anatomy of central PA, however, the accuracy was limited in two cases with bilateral SVC. The opacification of the intra-atrial baffle was insufficient in TCPC cases. Multi-phase CT angiography may overcome this limitation in this patient subset.
Unsrisong, Kittisak; Taphey, Siriporn; Oranratanachai, Kanokporn
2016-04-01
The object of this study was to evaluate the accuracy of fast 3D contrast-enhanced spinal MR angiography (MRA) using a manual syringe contrast injection technique for detecting and evaluating spinal arteriovenous shunts (AVSs). This was a retrospective study of 15 patients and 20 spinal MRA and catheter angiography studies. The accuracy of using spinal MRA to detect spinal AVS, localize shunts, and discriminate the subtype and dominant arterial feeder of the AVS were studied. There were 14 pretherapeutic and 6 posttherapeutic follow-up spinal MRA and catheter spinal angiography studies. The spinal AVS was demonstrated in 17 of 20 studies. Spinal MRA demonstrated 100% sensitivity for detecting spinal AVS with no false-negative results. A 97% accuracy rate for AVS subtype discrimination and shunt level localization was achieved using this study's diagnostic criteria. The detection of the dominant arterial feeder was limited to 9 of these 17 cases (53%). The fast 3D contrast-enhanced MRA technique performed using manual syringe contrast injection can detect the presence of a spinal AVS, locate the shunt level, and discriminate AVS subtype in most cases, but is limited when detecting small arterial feeders.
MEMS, Ka-Band Single-Pole Double-Throw (SPDT) Switch for Switched Line Phase Shifters
NASA Technical Reports Server (NTRS)
Scardelletti, Maximilian C.; Ponchak, George E.; Varaljay, Nicholas C.
2002-01-01
Ka-band MEMS doubly anchored cantilever beam capacitive shunt devices are used to demonstrate a MEMS SPDT switch fabricated on high resistivity silicon (HRS) utilizing finite ground coplanar waveguide (FGC) transmission lines. The SPDT switch has an insertion loss (IL), return loss (RL), and isolation of 0.3dB, 40dB, and 30 dB, respectively at Ka-band.
Distribution of extrahepatic congenital portosystemic shunt morphology in predisposed dog breeds
2012-01-01
Background An inherited basis for congenital extrahepatic portosystemic shunts (EHPSS) has been demonstrated in several small dog breeds. If in general both portocaval and porto-azygous shunts occur in breeds predisposed to portosystemic shunts then this could indicate a common genetic background. This study was performed to determine the distribution of extrahepatic portocaval and porto-azygous shunts in purebred dog populations. Results Data of 135 client owned dogs diagnosed with EHPSS at the Faculty of Veterinary Medicine of Utrecht University from 2001 – 2010 were retrospectively analyzed. The correlation between shunt localization, sex, age, dog size and breed were studied. The study group consisted of 54 males and 81 females from 24 breeds. Twenty-five percent of dogs had porto-azygous shunts and 75% had portocaval shunts. Of the dogs with porto-azygous shunts only 27% was male (P = 0.006). No significant sex difference was detected in dogs with a portocaval shunt. Both phenotypes were present in almost all breeds represented with more than six cases. Small dogs are mostly diagnosed with portocaval shunts (79%) whereas both types are detected. The age at diagnosis in dogs with porto-azygous shunts was significantly higher than that of dogs with portocaval shunts (P < 0.001). Conclusion The remarkable similarity of phenotypic variation in many dog breeds may indicate common underlying genes responsible for EHPSS across breeds. The subtype of EHPSS could be determined by a minor genetic component or modulating factors during embryonic development. PMID:22784395
Distribution of extrahepatic congenital portosystemic shunt morphology in predisposed dog breeds.
Van den Bossche, Lindsay; van Steenbeek, Frank G; Favier, Robert P; Kummeling, Anne; Leegwater, Peter A J; Rothuizen, Jan
2012-07-11
An inherited basis for congenital extrahepatic portosystemic shunts (EHPSS) has been demonstrated in several small dog breeds. If in general both portocaval and porto-azygous shunts occur in breeds predisposed to portosystemic shunts then this could indicate a common genetic background. This study was performed to determine the distribution of extrahepatic portocaval and porto-azygous shunts in purebred dog populations. Data of 135 client owned dogs diagnosed with EHPSS at the Faculty of Veterinary Medicine of Utrecht University from 2001 - 2010 were retrospectively analyzed. The correlation between shunt localization, sex, age, dog size and breed were studied. The study group consisted of 54 males and 81 females from 24 breeds. Twenty-five percent of dogs had porto-azygous shunts and 75% had portocaval shunts. Of the dogs with porto-azygous shunts only 27% was male (P = 0.006). No significant sex difference was detected in dogs with a portocaval shunt. Both phenotypes were present in almost all breeds represented with more than six cases. Small dogs are mostly diagnosed with portocaval shunts (79%) whereas both types are detected. The age at diagnosis in dogs with porto-azygous shunts was significantly higher than that of dogs with portocaval shunts (P < 0.001). The remarkable similarity of phenotypic variation in many dog breeds may indicate common underlying genes responsible for EHPSS across breeds. The subtype of EHPSS could be determined by a minor genetic component or modulating factors during embryonic development.
Gibson, Ashley; Kaplan, Sheldon L; Vallejo, Jesus G
2018-04-26
Coagulase-negative staphylococci (CoNS) are a common cause of pediatric ventricular shunt infections. The Infectious Diseases Society of America recommends vancomycin serum troughs of 15-20 µg/mL when treating CoNS shunt infections in adult patients. We report a series of pediatric cases of CoNS shunt infections in which clinical cure was obtained with troughs < 15 µg/mL. These findings question the relevance of this recommendation in pediatric patients. © 2018 S. Karger AG, Basel.
Torigoe, Masataka; Maeshima, Keisuke; Takeshita, Yasushi
2013-01-01
An 85-year-old woman was hospitalized with rapidly progressive paraparesis without altered consciousness, although she was not definitively diagnosed. She developed acute drowsiness and disorientation several days later. An intrahepatic portosystemic venous shunt (IPSVS) was observed on enhanced computed tomography, and hyperammonemia suggested leakage of neurotoxins from the shunt as the etiology of the patient's symptoms. Her neurological symptoms and hyperammonemia improved following transcatheter shunt embolization. We diagnosed her with hepatic myelopathy, which is a rare complication of liver cirrhosis and portosystemic venous shunts. Hepatic myelopathy resulting from a congenital IPSVS has not been previously reported. A diagnosis of hepatic myelopathy should be ruled out in diagnostically difficult cases of paraparesis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maleux, Geert; Pirenne, Jacques; Vaninbroukx, Johan
Our purpose was to assess the feasibility of orthotopic liver transplantation (OLT) in patients priorly having undergone transjugular intrahepatic portosystemic shunt (TIPS) with an expanded tetrafluoroethylene (e-PTFE)-covered endoprosthesis. In 48 patients an e- PTFE-covered endoprosthesis was inserted to treat severe complications of portal hypertension. In 36 patients the endoprosthesis was inserted during TIPS creation (de novo TIPS); in the other 12 patients the endoprosthesis was placed to repermeabilize the previously created, but occluded bare stent (revision TIPS). Eight of them (5 de novo and 3 revision cases) later underwent an OLT. The hospital records of these patients were reviewed frommore » initial admission, through TIPS, the pre-OLT period, and OLT to current postoperative status. Five de novo and 3 revision cases underwent OLT 4-279 days (mean delay: 80.8 days) after TIPS procedure. All OLT's were performed under veno-venous bypass surgery. De visu surgical inspection confirmed correct positioning of the fully patent stent graft, starting in the portal vein and ending at the junction of the hepatic vein to the inferior caval vein. No surgical difficulty was observed during proximal or distal clamping or during resection of the diseased liver. Correctly positioned e-PTFE-covered nitinol endoprostheses do not interfere with a later OLT and may not be considered as a contraindication in patients who need a TIPS as a bridge to OLT.« less
Multiple Colloid Cysts: Case Report and Literature Review.
Rizk, Ahmed R; Bettag, Martin
2018-06-14
Colloid cysts usually occur in the anterior third ventricle at the level of the foramina of Monro. Colloid cysts may extend from the third toward the lateral ventricle. We present a rare case of multiple intraventricular colloid cysts, two of which were in the third ventricle and one in the lateral ventricle. A 40-year-old female patient presented with three intraventricular cystic lesions: one cyst in the typical localization in the anterior rostral third ventricle, another cyst behind it in the same (third) ventricle, and a larger bulging cyst in the right lateral ventricle. A bilateral ventriculoperitoneal shunt had been inserted 26 years before to treat hydrocephalus. All three cysts had different magnetic resonance imaging (MRI) signal characteristics. We removed the cysts through an endoscopically assisted right transcortical transventricular microsurgical approach, using the right ventricular catheter as a guide to the lateral ventricle. After removal of the lateral ventricular cyst, we observed that the foramen of Monro was greatly enlarged (most likely as a result of the large cyst), which allowed us to remove the cysts in the third ventricle. During surgery, the cysts were found to have different consistencies. MRI 2 years following surgery showed complete removal and no hydrocephalus. The patient had no symptoms, and the clinical examinations were normal. Colloid cysts may become large and extend to the lateral ventricle, especially in patients treated with ventriculoperitoneal shunts. Studying the relevant pathoanatomy of these cysts is very important for preoperative planning including the choice of surgical approach. Georg Thieme Verlag KG Stuttgart · New York.
Rubio, Juan S; Rumbo, Carolina; Farinelli, Pablo A; Aguirre, Nicolás; Ramisch, Diego A; Paladini, Hugo; D Angelo, Pablo; Barros Schelotto, Pablo; Gondolesi, Gabriel E
2018-03-01
Collateral circulation secondary to liver cirrhosis may cause the development of large PSSs that may steal flow from the main portal circulation. It is important to identify these shunts prior to, or during the transplant surgery because they might cause an insufficient portal flow to the implanted graft. There are few reports of "steal flow syndrome" cases in pediatrics, even in biliary atresia patients that may have portal hypoplasia as an associated malformation. We present a 12-month-old female who received an uneventful LDLT from her mother, and the GRWR was 4.8. During the early post-operative period, she became hemodynamically unstable, developed ascites, and altered LFT. The post-operative ultrasound identified reversed portal flow, finding a non-anatomical PSS. A 3D CT scan confirmed the presence of a mesocaval shunt through the territory of the right gonadal vein, draining into the right iliac vein, with no portal inflow into the liver. The patient was re-operated, and the shunt was ligated. An intraoperative Doppler ultrasound showed adequate portal inflow after the procedure; the patient evolved satisfactorily and was discharged home on day number 49. The aim was to report a case of post-operative steal syndrome in a pediatric recipient due to a mesocaval shunt not diagnosed during the pretransplant evaluation. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Lee, Jong-Beom; Ahn, Ho-Young; Lee, Hong-Jae; Yang, Ji-Ho; Yi, Jin-Seok; Lee, Il-Woo
2017-01-01
The diagnosis of shunt malfunction can be challenging since neuroimaging results are not always correlated with clinical outcomes. The purpose of this study was to evaluate the efficacy of a simple, minimally invasive cerebrospinal fluid (CSF) lumbar tapping test that predicts shunt under-drainage in hydrocephalus patients. We retrospectively reviewed the clinical and radiological features of 48 patients who underwent routine CSF lumbar tapping after ventriculoperitoneal shunt (VPS) operation using a programmable shunting device. We compared shunt valve opening pressure and CSF lumbar tapping pressure to check under-drainage. The mean pressure difference between valve opening pressure and CSF lumbar tapping pressure of all patients were 2.21±24.57 mmH 2 O. The frequency of CSF lumbar tapping was 2.06±1.26 times. Eighty five times lumbar tapping of 41 patients showed that their VPS function was normal which was consistent with clinical improvement and decreased ventricle size on computed tomography scan. The mean pressure difference in these patients was -3.69±19.20 mmH 2 O. The mean frequency of CSF lumbar tapping was 2.07±1.25 times. Fourteen cases of 10 patients revealed suspected VPS malfunction which were consistent with radiological results and clinical symptoms, defined as changes in ventricle size and no clinical improvement. The mean pressure difference was 38.07±23.58 mmH 2 O. The mean frequency of CSF lumbar tapping was 1.44±1.01 times. Pressure difference greater than 35 mmH 2 O was shown in 2.35% of the normal VPS function group (2 of 85) whereas it was shown in 64.29% of the suspected VPS malfunction group (9 of 14). The difference was statistically significant ( p =0.000001). Among 10 patients with under-drainage, 5 patients underwent shunt revision. The causes of the shunt malfunction included 3 cases of proximal occlusion and 2 cases of distal obstruction and valve malfunction. Under-drainage of CSF should be suspected if CSF lumbar tapping pressure is 35 mmH 2 O higher than the valve opening pressure and shunt malfunction evaluation or adjustment of the valve opening pressure should be made.
Shunt attachment and method for interfacing current collection systems
Denney, P.E.; Iyer, N.C.; Hannan, W.F. III.
1992-12-08
A composite brush to shunt attachment wherein a volatile component of a composite but mostly metallic brush, used for current collection purposes, does not upon welding or brazing, adversely affect the formation of the interfacial bond with a conductive shunt which carries the current from the zone of the brush. The brush to shunt attachment for a brush material of copper-graphite composite and a shunt of copper, or substituting silver for copper as an alternative, is made through a hot isostatic pressing (HIP). The HIP process includes applying high pressure and temperature simultaneously at the brush to shunt interface, after it has been isolated or canned in a metal casing in which the air adjacent to the interface has been evacuated and the interfacial area has been sealed before the application of pressure and temperature. 6 figs.
Shunt attachment and method for interfacing current collection systems
Denney, Paul E.; Iyer, Natraj C.; Hannan, III, William F.
1992-01-01
A composite brush to shunt attachment wherein a volatile component of a composite but mostly metallic brush, used for current collection purposes, does not upon welding or brazing, adversely affect the formation of the interfacial bond with a conductive shunt which carries the current from the zone of the brush. The brush to shunt attachment for a brush material of copper-graphite composite and a shunt of copper, or substituting silver for copper as an alternative, is made through a hot isostatic pressing (HIP). The HIP process includes applying high pressure and temperature simultaneously at the brush to shunt interface, after it has been isolated or canned in a metal casing in which the air adjacent to the interface has been evacuated and the interfacial area has been sealed before the application of pressure and temperature.
Srinivasa, Ravi Nara; Majdalany, Bill S; Chick, Jeffrey Forris Beecham; Meadows, J Matthew; Fenlon, Jordan Bruce; Brewerton, Charles; Saad, Wael E
2018-01-01
In the setting of portal hypertension, the body responds by creating portosystemic venous shunts, which may lead to the development of varices. Endoscopic treatment of these varices is often warranted to prevent catastrophic bleeding. During the course of variceal treatment, 1 or more portosystemic shunts may be sacrificed, which may acutely exacerbate portal hypertension and reduce systemic venous return. This report describes percutaneous creation of a mesocaval shunt and balloon-occluded retrograde transvenous obliteration (BRTO) in a patient with cavernous transformation of the portal vein. The patient had previously undergone an unsuccessful attempt at transjugular intrahepatic portosystemic shunt (TIPS) creation with postoperative bleeding requiring splenectomy. As TIPS was not feasible, creation of a percutaneous mesocaval shunt provided an alternate pathway for portosystemic decompression, facilitating safe treatment of gastric varices with BRTO via a gastrorenal shunt. These procedures were performed simultaneously to reduce the risk of variceal bleeding from acute changes in portal venous pressures and redirect blood flow through the shunt to maintain patency. This is the first reported case of combined mesocaval shunt placement and BRTO in a single session. Copyright © 2017 Elsevier Inc. All rights reserved.
Interventional embolization of congenital intrahepatic shunts in children.
Wu, Lin; Zhao, Lu; Lu, Ying; He, Lan; Hu, Xihong
2016-04-01
Congenital intrahepatic shunts in children are rare and precise treatment strategies have not been established. The purpose of this study was to present our experience with transcatheter embolization in a descriptive case series of congenital intrahepatic shunts in children. We retrospectively studied 10 children with symptomatic congenital intrahepatic shunts who were treated with embolization at our institute between January 2008 and December 2014. Seven children had arteriovenous shunts in association with hepatic hemangiomas, two had arterioportal shunts and one had portosystemic shunts. The major presentations were congestive heart failure and severe anemia in the groups with arteriovenous and arterioportal shunts, respectively. Following embolization, two children died in the arteriovenous group, one from progressive liver dysfunction and the other from abdominal compartment syndrome. One child in the arterioportal group required liver transplantation after initial embolization. With mean post-procedure follow-up of 15 months (range 4-54 months), all the remaining children were well, with resolution of the symptoms. Interventional embolization provides an alternative to surgical ligation or hepatic resection in children with clinically significant intrahepatic shunts. For lesions with complex morphology, embolization may be inadequate and liver transplantation might be the only therapeutic option.
Serum hyaluronic acid in dogs with congenital portosystemic shunts.
Seki, M; Asano, K; Sakai, M; Kanno, N; Teshima, K; Edamura, K; Tanaka, S
2010-05-01
To compare the serum level of hyaluronic acid in dogs with congenital portosystemic shunt with that in healthy dogs and to investigate the perioperative change in serum hyaluronic acid following shunt attenuation. Blood samples were obtained from 29 congenital portosystemic shunt dogs before the operation, and 2 and 4 weeks after the operation from 17 and 7 dogs, respectively. The serum hyaluronic acid level of these dogs was measured and compared with that of 10 healthy beagles. The median preoperative hyaluronic acid level in dogs with congenital portosystemic shunt was significantly elevated compared with that in healthy dogs. Furthermore, the median postoperative hyaluronic acid level significantly decreased compared with the median preoperative levels in congenital portosystemic shunt dogs. In the case of dogs with congenital portosystemic shunt, the reduction of intrahepatic portal blood flow might lower the clearance rate of hyaluronic acid in hepatic sinusoidal endothelial cells, so hyaluronic acid clearance could be improved by attenuation of a shunt vessel. Hence, serum hyaluronic acid levels might be useful to evaluate liver function and also have the potential to evaluate successful attenuation of a shunt vessel in dogs with congenital portosystemic shunt. Further investigations are required to clarify whether serum hyaluronic acid offers significant benefits over existing markers such as serum bile acid or ammonia concentrations.
Turner, Michael S; Nguyen, Ha Son; Payner, Troy D; Cohen-Gadol, Aaron A
2011-07-01
Posterior fossa cysts are usually divided into Dandy-Walker malformations, arachnoid cysts, and isolated and/or trapped fourth ventricles. Shunt placement is a mainstay treatment for decompression of these fluid collections when their expansion becomes symptomatic. Although several techniques to drain symptomatic posterior fossa cysts have been described, each method carries its own advantages and disadvantages. This article describes an alternative technique. In 10 patients, the authors used an alternative technique involving stereotactic and endoscopic methods to place a catheter in symptomatic posterior fossa cysts across the tentorium. Discussion of these cases is included, along with a review of various approaches to shunt placement in this region and recommendations regarding the proposed technique. No patient suffered intracranial hemorrhage related to the procedure and catheter implantation. All 3 patients who underwent placement of a new transtentorial cystoperitoneal shunt and a new ventriculoperitoneal shunt did not suffer any postoperative complication; a decrease in the size of their posterior fossa cysts was evident on CT scans obtained during the 1st postoperative day. Follow-up CT scans demonstrated either stable findings or further interval decrease in the size of their cysts. In 1 patient, the postoperative head CT demonstrated that the transtentorial catheter terminated posterior to the right parietal occipital region without entering the retrocerebellar cyst. This patient underwent a repeat operation for proximal shunt revision, resulting in an acceptable catheter implantation. The patient in Case 8 suffered from a shunt infection and subsequently underwent hardware removal and aqueductoplasty with stent placement. The patient in Case 9 demonstrated a slight increase in fourth ventricle size and was returned to the operating room. Exploration revealed a kink in the tubing connecting the distal limb of the Y connector to the valve. The Y connector was replaced with a T connector, and 1 week later, CT scans exhibited interval decompression of the ventricles. This patient later presented with cranial wound breakdown and an exposed shunt. His shunt hardware was removed and he was treated with antibiotics. He later underwent reimplantation of a lateral ventricular and transtentorial shunt and suffered no other complications during a 3-year follow-up period. The introduction of endoscopic and stereotactic techniques has expanded the available treatment possibilities for posterior fossa cysts.
Holodny, A I; George, A E; de Leon, M J; Golomb, J; Kalnin, A J; Cooper, P R
1998-11-01
The authors describe a subgroup of patients with shunt-proven normal-pressure hydrocephalus (NPH) who presented with focal fissural and sulcal dilation on imaging studies. The specific radiological features and methods of differentiating this condition from cortical atrophy are delineated. Normal-pressure hydrocephalus has been described as dilation of the ventricles that is out of proportion to the sulci. Sulcal dilation has been taken as evidence of cortical atrophy and has even been used as a criterion to exclude patients from undergoing a shunting procedure. The authors describe five cases of patients with shunt-proven NPH who presented with focal dilation of cortical fissures and sulci. In three of the cases, there was a paradoxical decrease in the size of the dilated fissures and sulci that paralleled the decrease in the size of the lateral ventricles following successful shunting. This study demonstrates that focal fissural and sulcal dilation may represent reservoirs of cerebrospinal fluid analogous to the ventricular system. Patients should not be denied a shunting procedure solely on the basis of focally dilated fissures of sulci.
Armored brain: A case report and review of the literature.
Petraglia, Anthony L; Moravan, Michael J; Jahromi, Babak S
2011-01-01
Calcified chronic subdural hematomas occur infrequently. When the calcifications are extensive and bilateral, the condition is termed "armored brain". We describe a case of "armored brain" incidentally discovered in an adult presenting with abdominal pain and mild headaches, long after initial placement of a ventriculo-peritoneal (VP) shunt. A 38-year-old woman, treated at infancy with a VP shunt, presented with a 2-month history of abdominal pain associated with nausea and chills. She was neurologically intact on exam. An abdominal computed tomography (CT) scan demonstrated a rim-enhancing loculated fluid collection surrounding the patient's distal VP shunt catheter tip. As a part of her initial work-up, she received a head CT to evaluate the proximal VP shunt, which demonstrated large bilateral chronic subdural hematomas with heavily calcified walls. She was eventually taken to the operating room (OR) for replacement of the distal catheter. It was felt that her acute clinical presentation was unrelated to the bilateral, calcified subdural hematomas and thus the decision was made to manage them conservatively. This rare complication of chronic shunting for hydrocephalus is sometimes referred to as armored brain. Surgery for armored brain is infrequently indicated and beneficial in only small subgroup of patients, with management guided by clinical presentation. Our patient fully recovered after shunt revision alone.
Mesocaval Shunt Creation for Jejunal Variceal Bleeding with Chronic Portal Vein Thrombosis.
Yoon, Ja Kyung; Kim, Man Deuk; Lee, Do Yun; Han, Seok Joo
2018-01-01
The creation of transjugular intrahepatic portosystemic shunt (TIPS) is a widely performed technique to relieve portal hypertension, and to manage recurrent variceal bleeding and refractory ascites in patients where medical and/or endoscopic treatments have failed. However, portosystemic shunt creation can be challenging in the presence of chronic portal vein occlusion. In this case report, we describe a minimally invasive endovascular mesocaval shunt creation with transsplenic approach for the management of recurrent variceal bleeding in a portal hypertension patient with intra- and extrahepatic portal vein occlusion. © Copyright: Yonsei University College of Medicine 2018.
Congenital portosystemic venous shunt in a preterm Rh-isoimmunized infant.
Thukral, Anu; Arora, Kamaldeep; Das, Rashmi Ranjan; Arora, Arundeep; Gamanagatti, Shivanand; Agarwal, Ramesh K
2013-12-01
The authors report a preterm infant with Rh-isoimmunization, who had persistent hepato-splenomegaly with conjugated hyperbilirubinemia, transaminitis, and hyperammonemia. Ultrasound abdomen revealed an intrahepatic portosystemic venous shunt (PSVS). The child was managed conservatively. On follow up at 2.4 y of age, the child is having normal growth and development, but with persisting shunt. Severe Rh-isoimmunisation in a neonate can sometimes share some of the features of congenital PSVS and delay the diagnosis of the latter. The index case had shunt ratio >80 % during the neonatal period but did not require any intervention.
Congenital intrahepatic portosystemic shunt diagnosed during intrauterine life
Bellettini, Camila Vieira; Wagner, Rafaela; Balzanelo, Aleocídio Sette; Andretta, André Luis de Souza; de Moura, Arthur Nascimento; Fabris, Catia Carolina; Gubert, Eduardo Maranhão
2016-01-01
Abstract Objective: To report a patient with prenatal diagnosis of portosystemic shunt; a rare condition in humans. Case description: 17-Day-old female infant admitted for investigation of suspected diagnosis of portosystemic shunt, presumed in obstetric ultrasound. The hypothesis was confirmed after abdominal angiography and liver Doppler. Other tests such as echocardiography and electroencephalogram were performed to investigate possible co-morbidities or associated complications, and were normal. We chose conservative shunt treatment, as there were no disease-related complications and this was intrahepatic shunt, which could close spontaneously by the age of 2 years. Comments: Portosystemic shunt can lead to various complications such as hepatic encephalopathy, hypergalactosemia, liver tumors, and hepatopulmonary syndrome. Most diagnoses are done after one month of age, after such complications occur. The prenatal diagnosis of this patient provided greater security for the clinical picture management, as well as regular monitoring, which allows the anticipation of possible complications and perform interventional procedures when needed. PMID:27133713
Prevalence of patent foramen ovale with right-to-left shunting in dogs with pulmonic stenosis.
Fujii, Y; Nishimoto, Y; Sunahara, H; Takano, H; Aoki, T
2012-01-01
Right-to-left (R-L) shunt caused by patent foramen ovale (PFO) concurrent with pulmonic stenosis (PS) is considered common, although there is a lack of published evidence. To investigate the prevalence of R-L shunt caused by a PFO in dogs with PS. Thirty-one client-owned dogs with PS, without obvious extracardiac disease detected on the clinical examinations. Case control study: R-L shunt probably caused by PFO was diagnosed when IV injected microbubbles appeared at the left atrial level with an intact atrial septum on echocardiography (bubble-positive dogs). The severity of PS concurrent tricuspid regurgitation (TR), relative thickness of the right ventricle, and relative right atrial area were compared between bubble-positive and bubble-negative dogs. The prevalence of R-L shunts caused by PFO was 39% (12 of 31 cases). The instantaneous pressure gradient (PG) across the pulmonic valve and relative thickness of the right ventricle were significantly increased in bubble-positive compared with those in bubble-negative dogs. None of the dogs with mild or moderate PS (pressure gradient < 80 mm Hg, n = 2) demonstrated R-L shunt. The prevalence of TR in bubble-positive dogs was significantly higher than that in bubble-negative dogs. DISCUSSION AND CLINICAL RELEVANCE: Patent foramen ovale PFO with R-L shunt was more common in dogs with very severe PS and absent in dogs with mild PS. Copyright © 2011 by the American College of Veterinary Internal Medicine.
Morphology of congenital portosystemic shunts involving the right gastric vein in dogs.
White, R N; Parry, A T
2015-07-01
To describe the anatomy of congenital portosystemic shunts involving the right gastric vein in dogs. Retrospective review of a consecutive series of dogs managed for congenital portosystemic shunt. Twenty-two dogs met the inclusion criteria of a congenital portosystemic shunt involving the right gastric vein with recorded intraoperative mesenteric portovenography or computed tomography angiography and gross observations at the time of surgery. Of these, 20 (91%) had a shunt that entered the pre-hepatic caudal vena cava at the level of the epiploic foramen and two (9%) had a shunt that entered the post-hepatic caudal vena cava at the level of the diaphragm. Shunts entering the pre-hepatic caudal vena cava could be further classified into three consistent subdivisions. The morphology of each shunt type described appeared to be a result of an abnormal communication between the left gastric vein and the caudal vena cava, the presence or absence of an abnormal communication between the splenic, left gastric and portal veins and the subsequent development of preferential blood flow through essentially normal portal vessels within the portal venous system. The abnormal communication (shunt) was through the left gastric vein and not the right gastric vein, as might have been expected. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2015 British Small Animal Veterinary Association.
Meningitis caused by Oerskovia xanthineolytica.
Kailath, E J; Goldstein, E; Wagner, F H
1988-03-01
In summary, we describe a case of central nervous system infection with O. xanthineolytica in which the infecting microbe probably was engrafted on a ventricular shunt. The bacteria caused a smoldering meningitis that did not respond to penicillin and rifampin despite in vitro sensitivity, presumably because of inadequate cerebrospinal fluid penetration of the penicillin and the recognized difficulty of eradicating bacteria from contaminated shunts. Removal of the shunt and continued treatment with penicillin and rifampin resulted in cure.
Suazo, L.; Foerster, B.; Fermin, R.; Speckter, H.; Vilchez, C.; Oviedo, J.; Stoeter, P.
2012-01-01
Summary The assessment of shunt reduction after an embolization of an arteriovenous malformation (AVM) or fistula (AVF) from conventional angiography is often difficult and may be subjective. Here we present a completely non-invasive method using magnetic resonance imaging (MRI) to measure shunt reduction. Using pulsed arterial spin labeling (PASL), we determined the relative amount of signal attributed to the shunt over 1.75 s and 6 different slices covering the lesion. This amount of signal from the shunt was related to the total signal from all slices and measured before and after embolization. The method showed a fair agreement between the PASL results and the judgement from conventional angiography. In the case of a total or subtotal shunt occlusion, PASL showed a shunt reduction between 69% and 92%, whereas in minimal shunt reduction as judged by conventional angiography, the ASL result was –6% (indicating slightly increased flow) to 35% in a partially occluded vein of Galen aneurysm. The PASL method proved to be fairly reproducible (up to 2% deviation between three measurements without interventions). On conclusion, PASL is able to reliably measure the amount of shunt reduction achieved by embolization of AVMs and AVFs PMID:22440600
Pediatric neurosurgical practice patterns designed to prevent cerebrospinal fluid shunt infection.
Gruber, Thomas J; Riemer, Sara; Rozzelle, Curtis J
2009-01-01
Various factors have been associated with cerebrospinal fluid (CSF) shunt infection risk, leading to many recommendations intended to reduce that risk. We sought to assess current North American pediatric neurosurgical practice patterns in this regard via a web-based survey. Particular attention was paid to the use of antibiotic-impregnated materials and prophylactic perioperative antibiotics. The membership of the section on pediatric neurological surgery of the American Association of Neurological Surgeons and Congress of Neurological Surgeons was invited to complete a survey of current practices intended to minimize CSF shunt infection risk. To be eligible for participation in this study, the respondent had to maintain an active neurosurgical practice within North America and place or revise at least 25 shunts in pediatric patients (<21 years) per year. Responses to the questionnaire were then analyzed. A total of 100 responses were analyzed. All respondents were familiar with antibiotic-impregnated shunt catheters, and 61 of 100 had actually used them. Eleven of 61 respondents use them universally, 20 of 61 in >50% of cases, and 30 of 61 in <50% of cases. Antibiotic-impregnated suture material was known to 59% of respondents, of whom 28% (14 of 59) reported having actually used antimicrobial suture. All respondents use perioperative intravenous antibiotics with vancomycin, first-generation cephalosporins, and then second-generation cephalosporins being the most common. Routine use of intraventricular antibiotics was reported by 27%. An assessment of surgical techniques revealed that 90% limit shunt contact with patient's skin, 62% use the double-gloving technique, 45% handle shunt components only with instruments, and 34% use an antiseptic shampoo preoperatively. Our survey reveals a wide range of practices intended to prevent shunt infection and captures, in particular, current trends in the use of antibiotic-impregnated materials and perioperative antibiotics for CSF shunting procedures. Copyright 2010 S. Karger AG, Basel.
Intrahepatic portosystemic venous shunt associated with biliary atresia: case report.
Yamagami, T; Nakamura, T; Tokiwa, K; Ohno, K; Itoh, H; Maeda, T
2000-07-01
We describe an infant with intrahepatic portosystemic venous shunt (IPSVS), which was detected by MR angiography. IPSVS is rare and its cause is disputed. However, with improvements in imaging the number of reports of IPSVS identified incidentally in patients without definite symptoms is increasing. The present case is the first associated with congenital biliary atresia and the youngest reported in the literature.
Sakka, Laurent; Chomicki, Alexandre; Gabrillargues, Jean; Khalil, Toufic; Chazal, Jean; Avan, Paul
2016-02-01
Ventriculoperitoneal shunting is the first-line treatment for normal pressure hydrocephalus. Noninvasive auditory tests based on recorded otoacoustic emissions were assessed, as currently used for universal neonatal hearing screenings, for the diagnosis of cerebrospinal fluid shunt malfunction. The test was designed based on previous works, which demonstrated that an intracranial pressure change induces a proportional, characteristic, otoacoustic-emission phase shift. Forty-four patients with normal pressure hydrocephalus (23 idiopathic and 21 secondary cases) were included in this prospective observational study. The male:female sex ratio was 1.44, the age range was 21-87 years (mean age 64.3 years), and the range of the follow-up period was 1-3 years (mean 20 months). Patients were implanted with a Sophy SU8 adjustable-pressure valve as the ventriculoperitoneal shunt. The phase shifts of otoacoustic emissions in response to body tilt were measured preoperatively, immediately postoperatively, and at 3-6 months, 7-15 months, 16-24 months, and more than 24 months postoperatively. Three groups were enrolled: Group 1, 19 patients who required no valve opening-pressure adjustment; Group 2, 18 patients who required valve opening-pressure adjustments; and Group 3, 7 patients who required valve replacement. In Group 1, phase shift, which was positive before surgery, became steadily negative after surgery and during the follow-up. In Group 2, phase shift, which was positive before surgery, became negative immediately after surgery and increasingly negative after a decrease in the valve-opening pressure. In Group 3, phase shift was positive in 6 cases and slightly negative in 1 case before revision, but after revision phase shift became significantly negative in all cases. Otoacoustic emissions noninvasively reflect cerebrospinal fluid shunt function and are impacted by valve-opening pressure adjustments. Otoacoustic emissions consistently diagnosed shunt malfunction and predicted the need for surgical revision. The authors' diagnostic test, which can be repeated without risk or discomfort by an unskilled operator, may address the crucial need of detecting valve dysfunction in patients with poor clinical outcome after shunt surgery.
Interventional Radiology in the Management of Budd Chiari Syndrome
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beckett, David; Olliff, Simon, E-mail: simon.olliff@uhb.nhs.u
Budd Chiari syndrome is an uncommon condition in the Western world but interventional radiology can contribute significantly to the management of the majority of patients. This review examines the role and technique of interventions including hepatic vein dilatation and stent insertion as well as thrombolysis and TIPS. Liver transplantation and surgical shunt surgery are discussed in relation to radiological interventions. With appropriate selection and technique, surgery is only required in a minority of patients.
Liver resection for the treatment of a congenital intrahepatic portosystemic venous shunt.
Papamichail, Michail; Ali, Amir; Quaglia, Alberto; Karani, John; Heaton, Nigel
2016-06-01
Intrahepatic portosystemic shunts (IPSS) are rare congenital anomalies arising from disordered portal vein embryogenesis. It has been described in both children and adults and may be asymptomatic or be associated with a variety of neurophysiological and pulmonary complications. When recognized, early intervention to occlude the shunt will reverse the associated complications. Literature review reports of surgical and radiological occlusion of the shunt, but due to its rarity, a standard therapeutic protocol has not been established. A case of a 38-year-old woman with abdominal pain and low grade encephalopathy, diagnosed with an IPSS and treated by right hepatectomy was reported.
Lee, Jong-Beom; Ahn, Ho-Young; Lee, Hong-Jae; Yang, Ji-Ho; Yi, Jin-Seok; Lee, Il-Woo
2017-01-01
Objective The diagnosis of shunt malfunction can be challenging since neuroimaging results are not always correlated with clinical outcomes. The purpose of this study was to evaluate the efficacy of a simple, minimally invasive cerebrospinal fluid (CSF) lumbar tapping test that predicts shunt under-drainage in hydrocephalus patients. Methods We retrospectively reviewed the clinical and radiological features of 48 patients who underwent routine CSF lumbar tapping after ventriculoperitoneal shunt (VPS) operation using a programmable shunting device. We compared shunt valve opening pressure and CSF lumbar tapping pressure to check under-drainage. Results The mean pressure difference between valve opening pressure and CSF lumbar tapping pressure of all patients were 2.21±24.57 mmH2O. The frequency of CSF lumbar tapping was 2.06±1.26 times. Eighty five times lumbar tapping of 41 patients showed that their VPS function was normal which was consistent with clinical improvement and decreased ventricle size on computed tomography scan. The mean pressure difference in these patients was −3.69±19.20 mmH2O. The mean frequency of CSF lumbar tapping was 2.07±1.25 times. Fourteen cases of 10 patients revealed suspected VPS malfunction which were consistent with radiological results and clinical symptoms, defined as changes in ventricle size and no clinical improvement. The mean pressure difference was 38.07±23.58 mmH2O. The mean frequency of CSF lumbar tapping was 1.44±1.01 times. Pressure difference greater than 35 mmH2O was shown in 2.35% of the normal VPS function group (2 of 85) whereas it was shown in 64.29% of the suspected VPS malfunction group (9 of 14). The difference was statistically significant (p=0.000001). Among 10 patients with under-drainage, 5 patients underwent shunt revision. The causes of the shunt malfunction included 3 cases of proximal occlusion and 2 cases of distal obstruction and valve malfunction. Conclusion Under-drainage of CSF should be suspected if CSF lumbar tapping pressure is 35 mmH2O higher than the valve opening pressure and shunt malfunction evaluation or adjustment of the valve opening pressure should be made. PMID:28061484
Khan, Rabia; Oakes, Peter; Tubbs, R Shane; Oakes, W Jerry
2017-01-01
Chiari I malformation can be due to a multitude of etiologies such as craniosynostosis or hydrocephalus. A posterior fossa extra-axial cyst (PFEAC) appears to be an extremely rare cause of this form of hindbrain herniation. Herein, we report a case of PFEAC that presented with no Chiari I malformation and then presented months later with a significant Chiari I malformation. Following shunt placement of a PFEAC, striking reversal of the Chiari malformation as well as reconstitution of the cerebellum was noted. Patients with PFEAC might develop a Chiari I malformation and this might be treated with shunting of the PFEAC alone.
Comparative durability and costs analysis of ventricular shunts.
Agarwal, Nitin; Kashkoush, Ahmed; McDowell, Michael M; Lariviere, William R; Ismail, Naveed; Friedlander, Robert M
2018-05-11
OBJECTIVE Ventricular shunt (VS) durability has been well studied in the pediatric population and in patients with normal pressure hydrocephalus; however, further evaluation in a more heterogeneous adult population is needed. This study aims to evaluate the effect of diagnosis and valve type-fixed versus programmable-on shunt durability and cost for placement of shunts in adult patients. METHODS The authors retrospectively reviewed the medical records of all patients who underwent implantation of a VS for hydrocephalus at their institution over a 3-year period between August 2013 and October 2016 with a minimum postoperative follow-up of 6 months. The primary outcome was shunt revision, which was defined as reoperation for any indication after the initial procedure. Supply costs, shunt durability, and hydrocephalus etiologies were compared between fixed and programmable valves. RESULTS A total of 417 patients underwent shunt placement during the index time frame, consisting of 62 fixed shunts (15%) and 355 programmable shunts (85%). The mean follow-up was 30 ± 12 (SD) months. The shunt revision rate was 22% for programmable pressure valves and 21% for fixed pressure valves (HR 1.1 [95% CI 0.6-1.8]). Shunt complications, such as valve failure, infection, and overdrainage, occurred with similar frequency across valve types. Kaplan-Meier survival curve analysis showed no difference in durability between fixed (mean 39 months) and programmable (mean 40 months) shunts (p = 0.980, log-rank test). The median shunt supply cost per index case and accounting for subsequent revisions was $3438 (interquartile range $2938-$3876) and $1504 (interquartile range $753-$1584) for programmable and fixed shunts, respectively (p < 0.001, Wilcoxon rank-sum test). Of all hydrocephalus etiologies, pseudotumor cerebri (HR 1.9 [95% CI 1.2-3.1]) and previous shunt malfunction (HR 1.8 [95% CI 1.2-2.7]) were found to significantly increase the risk of shunt revision. Within each diagnosis, there were no significant differences in revision rates between shunts with a fixed valve and shunts with a programmable valve. CONCLUSIONS Long-term shunt revision rates are similar for fixed and programmable shunt pressure valves in adult patients. Hydrocephalus etiology may play a significant role in predicting shunt revision, although programmable valves incur higher supply costs regardless of initial diagnosis. Utilization of fixed pressure valves versus programmable pressure valves may reduce supply costs while maintaining similar revision rates. Given the importance of developing cost-effective management protocols, this study highlights the critical need for large-scale prospective observational studies and randomized clinical trials of ventricular shunt valve revisions and additional patient-centered outcomes.
Chira, Romeo Ioan; Calauz, Adriana; Manole, Simona; Valean, Simona; Mircea, Petru Adrian
2017-03-01
Congenital extrahepatic portosystemic shunt (Abernethy malformation) is a rare condition characterized by developmental abnormalities of the portal venous system resulting in the diversion of the portal blood from the liver to the systemic venous system through a complete or partial shunt of the portomesenteric blood. We report the case of an 18 year-old female examined for abdominal pain, presenting cholestasis syndrome and an elevated serum aspartate aminotransferase level. Liver ultrasound examination revealed the absence of the portal vein with a complete extrahepatic shunt of the portal blood, multiple focal liver lesions, and multiple associated vascular anomalies. A surgical portosystemic shunt and a secondary portosystemic shunt due to portal vein thrombosis were excluded, enabling the diagnosis of a congenital portosystemic shunt. A complex investigation also discovered bone anomalies, and the liver biopsy of the dominant focal lesion revealed adenoma. On a short-term follow-up under hepatoprotective medication, the biochemical parameters improved mildly; however, the size of the main focal lesion increased. Congenital absence of the portal vein often remains an incidental diagnosis. In experienced hands, ultrasonography can diagnose it, but a comprehensive thoraco-abdominal evaluation is compulsory, considering the many potential associated anomalies. In these patients, development of adenomatous liver lesions secondary to Abernethy type Ib malformation represents an indication for liver transplantation.
Adult manifestation of the Dandy-Walker syndrome. Report of two cases with review of the literature.
Unsgaard, G; Sand, T; Støvring, J; Ringkjøb, R
1987-01-01
Two cases of Dandy-Walker syndrome that became manifest in adult life are reported. A review of the literature of Dandy-Walker syndrome revealed 13 additional cases with onset in adult life and three cases that could not be differentiated from arachnoid cysts. While shunting is the primary treatment in infantile Dandy-Walker, the usual treatment of adult Dandy-Walker has been excision of the membrane covering the enlarged fourth ventricle. The outcome of our two cases treated with membrane excision indicates that primary shunting should also be tried in adult Dandy-Walker.
Reversible Venting Stitch for Fenestrating Valve-less Glaucoma Shunts.
Akil, Handan; Vu, Priscilla Q; Nguyen, Anhtuan H; Nugent, Alexander; Chopra, Vikas; Francis, Brian A; Tan, James C
2017-12-01
The purpose of this is to describe a venting stitch modification for valveless glaucoma aqueous shunts and characterize early postoperative intraocular pressure (IOP) and glaucoma medication use following the modification. Retrospective chart review of 61 sequential patients undergoing Baerveldt glaucoma implant (BGI)-350 implantation at the Doheny Eye Institute. Twenty-four patients received a glaucoma shunt with venting stitch modification (modified BGI) and 37 patients received an unmodified shunt (BGI-only). IOP, number of glaucoma medications, and number of hypotony cases (intraocular pressure ≤5 mm Hg) were compared between the groups. T-tests were used for statistical analysis. At postoperative-day 1, mean IOP was significantly lower compared with preoperatively in the modified BGI group (14 mm Hg; reduced by 51%; P<0.0001) but not the BGI-only group (27 mm Hg; P=0.06). IOP difference between groups persisted till immediately before tube opening (P=0.005) and fewer IOP-lowering medications needed in the modified BGI group (P<0.0001). One case (4.2%) of postoperative hypotony was encountered with BGI modification, which resolved after the stitch was removed in clinic. The venting stitch valveless shunt modification allows for effective, reliable, and safe control of early postoperative IOP.
The long-term prognosis of congenital portosystemic venous shunt.
Uchino, T; Matsuda, I; Endo, F
1999-08-01
Congenital portosystemic venous shunt (PSVS), considered to be a rare disease, can lead to hepatic encephalopathy (HE). With improvements in diagnostic imaging techniques, the number of infants and children with documented PSVS has increased. The natural course of the disease and indications for surgical closure of the shunt vessel have not been well defined. We reviewed 51 cases of congenital PSVS in Japan; 34 patients had an intrahepatic PSVS, and 17 had an extrahepatic PSVS. There were 12 patients with HE at the time of diagnosis. The frequency of HE increased in subjects over 60 years of age. Children with HE had a shunt ratio exceeding 60%. When the shunt ratio was less than 30%, HE did not occur. Twenty of 28 patients under the age of 15 years had hypergalactosemia at the time of neonatal screening. Part of the congenital intrahepatic PSVS spontaneously closed. Surgical closure of a PSVS may be an approach expected to prevent HE when the shunt ratio exceeds 60%.
Golewale, Nazar; Paltiel, Harriet J; Fishman, Steven J; Alomari, Ahmad I
2010-08-01
The occurrence of portal vascular anomalies in Down syndrome has been sporadically reported in the literature. These rare disorders have a wide spectrum of anatomical and clinical presentations. The aim of this communication was to describe the clinical course, imaging features, and management approaches in patients with this association. We conducted a comprehensive search of the databases of the Vascular Anomalies Center and the Department of Radiology at Children's Hospital Boston for patients with Down syndrome and portal vascular anomalies. Medical records and imaging studies of varying modalities were reviewed. Three children with Down syndrome and portal anomalies (portosystemic shunt, simple arterioportal shunt, complex arterioportal shunt) were managed at our institution. The portosystemic shunt was clinically insignificant and resolved without any intervention. The simple arterioportal shunt was successfully treated with embolization. The complex arterioportal shunt was associated with major congenital cardiac defects and the child ultimately expired despite a decrease in the arterioportal shunting after embolization. Three is a wide spectrum of clinical and anatomical features of portal vascular shunts in Down syndrome. The management approach should be tailored based on the severity of symptoms. Percutaneous embolization can offer a safe, effective, and minimally invasive alternative to the surgical approach in selective cases. Copyright 2010 Elsevier Inc. All rights reserved.
Sæhle, Terje; Eide, Per Kristian
2015-05-01
OBJECT In patients with hydrocephalus and shunts, lasting symptoms such as headache and dizziness may be indicative of shunt failure, which may necessitate shunt revision. In cases of doubt, the authors monitor intracranial pressure (ICP) to determine the presence of over- or underdrainage of CSF to tailor management. In this study, the authors reviewed their experience of ICP monitoring in shunt failure. The aims of the study were to identify the complications and impact of ICP monitoring, as well as to determine the mean ICP and characteristics of the cardiac-induced ICP waves in pediatric versus adult over- and underdrainage. METHODS The study population included all pediatric and adult patients with hydrocephalus and shunts undergoing diagnostic ICP monitoring for tentative shunt failure during the 10-year period from 2002 to 2011. The patients were allocated into 3 groups depending on how they were managed following ICP monitoring: no drainage failure, overdrainage, or underdrainage. While patients with no drainage failure were managed conservatively without further actions, over- or underdrainage cases were managed with shunt revision or shunt valve adjustment. The ICP and ICP wave scores were determined from the continuous ICP waveforms. RESULTS The study population included 71 pediatric and 75 adult patients. There were no major complications related to ICP monitoring, but 1 patient was treated for a postoperative superficial wound infection and another experienced a minor bleed at the tip of the ICP sensor. Following ICP monitoring, shunt revision was performed in 74 (51%) of 146 patients, while valve adjustment was conducted in 17 (12%) and conservative measures without any actions in 55 (38%). Overdrainage was characterized by a higher percentage of episodes with negative mean ICP less than -5 to -10 mm Hg. The ICP wave scores, in particular the mean ICP wave amplitude (MWA), best differentiated underdrainage. Neither mean ICP nor MWA levels showed any significant association with age. CONCLUSIONS In this cohort of pediatric and adult patients with hydrocephalus and tentative shunt failure, the risk of ICP monitoring was very low, and helped the authors avoid shunt revision in 49% of the patients. Mean ICP best differentiated overdrainage, which was characterized by a higher percentage of episodes with negative mean ICP less than -5 to -10 mm Hg. Underdrainage was best characterized by elevated MWA values, indicative of impaired intracranial compliance.
Cerebrospinal fluid eosinophilia and sterile shunt malfunction.
Traynelis, V C; Powell, R G; Koss, W; Schochet, S S; Kaufman, H H
1988-11-01
Cerebrospinal fluid (CSF) eosinophilia is a rare finding most often associated with central nervous system inflammatory processes, including parasitic, bacterial, and mycotic infections. It has also been seen as an allergic phenomenon. We present two cases of CSF eosinophilia occurring concurrently with sterile shunt malfunction. We speculate that CSF eosinophilia in our patients might have resulted from an allergic response to a foreign material such as suture, surgical glove powder, hair, cotton fibers, antibiotics, or silicone rubber. The incidence of sterile CSF eosinophilia after shunting is not known. Information concerning the role of eosinophilia in the development of shunt malfunctions is also lacking. An increased awareness of this possibility and further investigation are warranted.
Intrathecal Baclofen Therapy in a Child With Severe Scoliosis: Report of 2 Cases.
Sasaki, Natsu; Ogiwara, Hideki
2016-08-01
Scoliosis is commonly found in children with cerebral palsy. Many patients with cerebral palsy and scoliosis undergo intrathecal baclofen (ITB) pump placement. The authors report 2 cases with cerebral palsy and severe scoliosis treated with intrathecal baclofen. The case of a 7-year-old boy with shunted hydrocephalus required surgical revision of the intrathecal catheter, while the other patient without shunt did not require revision. In the patient with shunted hydrocephalus, after the initial placement of baclofen pump and catheter at Th3 level, spasticity of lower extremities did not improve. The Indium(111) diethylenetriamine pentaacetic acid (In(111) DTPA) scintigraphy with injection of In(111) DTPA through the pump did not demonstrate distribution of the tracer to the lumbosacral area. Conversely, by direct injection of In(111) DTPA through lumbar puncture, the tracer distributed in the whole spinal canal. Replacement of the tip of the catheter caudal to the curve of the scoliosis improved the symptom. The authors suggest that, in patients with severe scoliosis and shunted hydrocephalus, it may be necessary to place the tip of the catheter caudal to the curve of the scoliosis for correction of spasticity of lower extremities. © 2016 International Neuromodulation Society.
Combined repair of adult coarctation of the aorta and aortic valvular stenosis.
Ivert, T; Busund, R; Avenarius, D; Dahi, P E
2000-06-01
A 57-year-old man with a high-grade aortic stenosis and aortic coarctation was treated with concomitant valve replacement and insertion of a conduit from the ascending aorta to the retrocardiac descending aorta via the left pleura. Because heart failure has been reported shortly after cardiopulmonary bypass using this technique, the conduit was initially clamped until the postrepair haemodynamics was stable. Computed tomography after 14 months verified patency of the shunt.
Congenital portosystemic shunt: our experience.
Timpanaro, Tiziana; Passanisi, Stefano; Sauna, Alessandra; Trombatore, Claudia; Pennisi, Monica; Petrillo, Giuseppe; Smilari, Pierluigi; Greco, Filippo
2015-01-01
Introduction. Congenital portosystemic venous malformations are rare abnormalities in which the portal blood drains into a systemic vein and which are characterized by extreme clinical variability. Case Presentations. The authors present two case reports of a congenital extrahepatic portosystemic shunt (Type II). In the first patient, apparently nonspecific symptoms, such as headache and fatigue, proved to be secondary to hypoglycemic episodes related to the presence of a portosystemic shunt, later confirmed on imaging. During portal vein angiography, endovascular embolization of the portocaval fistula achieved occlusion of the anomalous venous tract. In the second patient, affected by Down's syndrome, the diagnosis of a portosystemic malformation was made by routine ultrasonography, performed to rule out concurrent congenital anomalies. Because of the absence of symptoms, we chose to observe this patient. Conclusions. These two case reports demonstrate the clinical heterogeneity of this malformation and the need for a multidisciplinary approach. As part of a proper workup, clinical evaluation must always be followed by radiographic diagnosis.
Two cases of scimitar variant.
Takeda, S; Imachi, T; Arimitsu, K; Minami, M; Hayakawa, M
1994-01-01
The scimitar sign is characteristic of partial anomalous pulmonary venous drainage into the inferior vena cava (IVC). We encountered two variant cases of scimitar sign. In one case, the scimitar vein entered both the IVC and the left atrium (LA) without any intracardiac shunts. Surgical repair was made by simple ligation of the scimitar vein to correct the left to right shunt. Retrograde balloon occlusion angiography of the scimitar vein was diagnostic. In the other case, the scimitar vein showed a meandering course, and then drained into the LA without any connection with the IVC, and surgical intervention was not required.
Houten, John K; Smith, Shiela; Schwartz, Amit Y
2017-08-01
Ventriculoperitoneal (VP) shunting is a common neurosurgical procedure to treat hydrocephalus that diverts cerebrospinal fluid from the cerebral ventricles to the peritoneal cavity for reabsorption. The distal catheter may potentially migrate through any potential or iatrogenic opening in the peritoneal cavity. Increasingly successfully management of childhood hydrocephalus and adult-onset conditions leading to hydrocephalus, such as subarachnoid hemorrhage, is leading many adult female patients harboring VP shunts needing to undergo hysterectomy. Hysterectomy creates a potential defect though which a VP shunt catheter may migrate. It is not known whether the hysterectomy cuff closure technique may affect the likelihood of distal catheter migration though the repair site. We report the case of a 38-year-old woman with a VP shunt who underwent laparoscopic hysterectomy via an open vaginal cuff technique who subsequently presented with vaginal cerebrospinal fluid leakage secondary to migration of the distal shunt catheter through the hysterectomy cuff. Vaginal migration of the distal VP shunt catheter is a possible complication of hysterectomy. The authors postulate that an open cuff hysterectomy closure technique may increase the risk of catheter migration, an issue that may be better understood with further investigation. Copyright © 2017 Elsevier Inc. All rights reserved.
Electron microscopic evaluation of a gold glaucoma micro shunt after explantation.
Berk, Thomas A; Tam, Diamond Y; Werner, Liliana; Mamalis, Nick; Ahmed, Iqbal Ike K
2015-03-01
We present a case of an explanted gold glaucoma micro shunt (GMS Plus) and the subsequent light and electron microscopic analyses. The shunt was implanted in a patient with medically refractive glaucoma. The intraocular pressure (IOP) was stable at 12 mm Hg 6 months postoperatively but spiked to 26 mm Hg 6 months later; membranous growth was visible on the implant gonioscopically. A second gold micro shunt was placed 2 years after the first. The IOP was 7 mm Hg 1 week postoperatively but increased to 23 mm Hg 3 weeks later; similar membranous growth was visible on this implant. One of the shunts was explanted, and light and scanning electron microscopic analyses revealed encapsulation around the shunt exterior and connective tissue invasion of the microstructure. This represents the first electron microscopic analysis of an explanted gold glaucoma micro shunt and the first unequivocal images of the fibrotic pseudo-capsule traversing its microchannels and fenestrations. Dr. Ahmed is a consultant to and has received research grants from Solx, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Congenital veno-venous malformations of the liver: widely variable clinical presentations.
Witters, Peter; Maleux, Geert; George, Christophe; Delcroix, Marion; Hoffman, Ilse; Gewillig, Marc; Verslype, Chris; Monbaliu, Diethard; Aerts, Raymond; Pirenne, Jacques; Van Steenbergen, Werner; Nevens, Frederik; Fevery, Johan; Cassiman, David
2008-08-01
Congenital portosystemic veno-venous malformations are rare abnomalities that often remain undiagnosed. Typically they are classified by their anatomical characteristics according to Morgan (extrahepatic, Abernethy malformations type Ia,b and II) and Park (intrahepatic, types 1-4). However, their clinical presentation is less dependent on the anatomical type. We reviewed the clinical characteristics of six cases drawn from our files (from 1970 to 2006). One patient, a 25-year-old male, had extrahepatic shunting whereby the liver receives only arterial blood because the portal vein (PV) connects with the inferior caval vein (ICV) (Abernethy Ib); he presented with episodes of jaundice and pruritus. Three patients had extrahepatic shunting with patent intrahepatic portal veins, but with shunting of splenomesenterial blood towards the ICV (Abernethy II); these included a 66-year-old male with hepatic encephalopathy, a 17-year-old female with (porto?-)pulmonary hypertension without portal hypertension, and a 33-year-old female with epidsodes of acute pain secondary to spontaneous bleeding within a primary liver tumor. Two patients had intrahepatic shunting; these included an 8-year-old boy who was diagnosed incidentally during work-up for abnormal liver enzymes with a communication between right PV and ICV (Park type 1), and a 59-year-old male with multiple PV-ICV-shunts in several liver segments (Park, type 4) who presented with hepatic encephalopathy. Patients often present with signs of hepatic shunting (encephalopathy, pulmonary hypertension, hepatopulmonary syndrome, and/or hypoglycemia) with relative sparing of the synthetic liver function in the absence of portal hypertension. Some shunts present with space-occupying lesions (focal nodular hyperplasia, hepatocellular carcinoma, nodular regenerative hyperplasia, etc.) or biliary atresia. Finally, some cases are detected incidentally.
A new shunt for obstructive hydrocephalus: ventricle-Sylvian fissure shunt A preliminary report.
Patkar, Sushil
2017-06-01
Cerbrospinal fluid (CSF) pathway studies have revealed that after egressing from the fourth ventricle reaches the basal supra sellar cistern and ultimately the sylvian cisterns from where the CSF travels over the cerebral convexity subarachnoid space to reach the superior saggital sinus and enters the blood stream. Diverting CSF from the lateral ventricle with a shunt catheter to the sylvian cistern can be an option to treat obstructive hydrocephalus. 2 patients underwent this procedure of diverting CSF from the lateral ventricle with a shunt catheter (Chabbra, India) to the sylvian cistern successfully and had immediate relief of symptoms of raised intracranial pressure. Additional 4 patients had relief for 3mths to 6 mths and are under follow up. Though preliminary results seem logical and promising, more cases and longer follow-up is required to consider this shunt operation as an option in treatment of obstructive hydrocephalus.
Autologous patch graft in tube shunt surgery.
Aslanides, I M; Spaeth, G L; Schmidt, C M; Lanzl, I M; Gandham, S B
1999-10-01
To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. A retrospective study of 16 patients (17 eyes) who underwent tube shunt surgery at Wills Eye Hospital between July 1991 and October 1996 was conducted. An autologous either "free" or "rotating" scleral lamellar graft was created to cover the subconjunctival portion of the tube shunt. All patients were evaluated for at least 6 months, with a mean follow-up of 14.8 months (range 6-62 months). All eyes tolerated the autologous graft well, with no clinical evidence of tube erosion, or graft-related or intraocular complications. Autologous patch graft in tube shunt surgery appears--in selected cases--to be an effective, safe and inexpensive surgical alternative to allogenic graft materials. It also offers ease of availability, and eliminates the risk of transmitting infectious disease.
Tomás Pujante, Paula; Jiménez Sánchez, Andrés Francisco; Iglesias Jorquera, Elena; Pons Miñano, José Antonio
2018-04-24
Splenorenal shunts are a rare cause of hyperammonemia and hepatic encephalopathy in the absence of cirrhosis. We report the case of a woman, who presented hepatic encephalopathy, with a normal functioning graft, after 14 years of liver transplantation, confirmed by liver biopsy.
Intrahepatic portosystemic venous shunt: diagnosis by color Doppler imaging.
Kudo, M; Tomita, S; Tochio, H; Minowa, K; Todo, A
1993-05-01
Intrahepatic portosystemic venous shunt is a rare clinical entity; only 33 such cases have been reported. It may be congenital, or secondary to portal hypertension. Five patients with this disorder are presented, each of whom was diagnosed by color Doppler imaging, including waveform spectral analysis. One patient with clinical evidence of cirrhosis and portal hypertension had episodes of hepatic encephalopathy and elevated blood levels of ammonia. This patient had a large tubular shunt between the posterior branch of the portal vein and the inferior vena cava. Shunts of this type are considered to be collateral pathways which develop in the hepatic parenchyma as a result of portal hypertension. The other four patients had no evidence of liver disease, and all four evidenced an aneurysmal portohepatic venous shunt within the liver parenchyma. Shunts of this type are considered congenital. The diagnosis of intrahepatic portosystemic venous shunts was established by color Doppler imaging, which demonstrated a direct communication of color flow signals between the portal vein and hepatic vein, in addition to the characterization of the Doppler spectrum at each sampling point from a continuous waveform signal (portal vein) to a turbulent signal (aneurysmal cavity), and finally, to a biphasic waveform signal (hepatic vein). As demonstrated by the five patients, color Doppler imaging is useful in the diagnosis of an intrahepatic portosystemic hepatic venous shunt, and the measurement of shunt ratio may be useful in the follow-up and determining the therapeutic option.
Shunt Devices for the Treatment of Adult Hydrocephalus: Recent Progress and Characteristics
MIYAKE, Hiroji
2016-01-01
Various types of shunt valves have been developed during the past 50 years, most of which can be classified into the following categories: (1) fixed differential pressure valves; (2) fixed differential pressure (DP) valves with an antisiphon mechanism; (3) programmable DP valves; (4) programmable DP valves with an antisiphon mechanism; and (5) programmable antisiphon valves. When considering the myriad of possible postoperative condition changes, such as the onset of accidental non-related diseases or trauma in adults, and changes in normal physiological development or anticipation of future shunt removal in children, it has become standard to use the programmable valve as a first choice for cerebrospinal fluid shunting. However, it is still unclear what type of shunt valve is suitable for each individual case. Based on the results of SINPHONI and more recently SINPHONI 2 trials, the programmable DP valve is recommended as the first line shunt valve. The programmable DP valve with an antisiphon mechanism is thought to be beneficial for tall, slender patients, who have a tendency for easily developing complications of overdrainage, however, this type of valve must be used cautiously in obese patients because of the increased risk of underdrainage. Although the current evidence is still insufficient, the programmable antisiphon valve, which costs the same as the programmable DP valve, is also thought to be the first line shunt valve. The quick reference table is applicable for most shunt valves, and for patients with either the ventriculoperitoneal or the lumboperitoneal shunt. PMID:27041631
Shunt Devices for the Treatment of Adult Hydrocephalus: Recent Progress and Characteristics.
Miyake, Hiroji
2016-05-15
Various types of shunt valves have been developed during the past 50 years, most of which can be classified into the following categories: (1) fixed differential pressure valves; (2) fixed differential pressure (DP) valves with an antisiphon mechanism; (3) programmable DP valves; (4) programmable DP valves with an antisiphon mechanism; and (5) programmable antisiphon valves. When considering the myriad of possible postoperative condition changes, such as the onset of accidental non-related diseases or trauma in adults, and changes in normal physiological development or anticipation of future shunt removal in children, it has become standard to use the programmable valve as a first choice for cerebrospinal fluid shunting. However, it is still unclear what type of shunt valve is suitable for each individual case. Based on the results of SINPHONI and more recently SINPHONI 2 trials, the programmable DP valve is recommended as the first line shunt valve. The programmable DP valve with an antisiphon mechanism is thought to be beneficial for tall, slender patients, who have a tendency for easily developing complications of overdrainage, however, this type of valve must be used cautiously in obese patients because of the increased risk of underdrainage. Although the current evidence is still insufficient, the programmable antisiphon valve, which costs the same as the programmable DP valve, is also thought to be the first line shunt valve. The quick reference table is applicable for most shunt valves, and for patients with either the ventriculoperitoneal or the lumboperitoneal shunt.
The Evolution of Transjugular Intrahepatic Portosystemic Shunt: Tips
Fanelli, Fabrizio
2014-01-01
Since Richter's description in the literature in 1989 of the first procedure on human patients, transjugular intrahepatic portosystemic shunt (TIPS) has been worldwide considered as a noninvasive technique to manage portal hypertension complications. TIPS succeeds in lowering the hepatic sinusoidal pressure and in increasing the circulatory flow, thus reducing sodium retention, ascites recurrence, and variceal bleeding. Required several revisions of the shunt TIPS can be performed in case of different conditions such as hepatorenal syndrome, hepatichydrothorax, portal vein thrombosis, and Budd-Chiari syndrome. Most of the previous studies on TIPS procedure were based on the use of bare stents and most patients chose TIPS 2-3 years after traditional treatment, thus making TIPS appear to be not superior to endoscopy in survival rates. Bare stents were associated with higher incidence of shunt failure and consequently patients required several revisions during the follow-up. With the introduction of a dedicated e-PTFE covered stent-graft, these problems were completely solved, No more reinterventions are required with a tremendous improvement of patient's quality of life. One of the main drawbacks of the use of e-PTFE covered stent-graft is higher incidence of hepatic encephalopathy. In those cases refractory to the conventional medical therapy, a shunt reduction must be performed. PMID:27335841
Ritz, Rainer; Roser, Florian; Morgalla, Matthias; Dietz, Klaus; Tatagiba, Marcos; Will, Bernd E
2007-01-01
Background Shunt infection in hydrocephalus patients is a severe, even life-threatening complication. Antibiotic-impregnated shunts (AIS) have been developed in an attempt to reduce rate of shunt infection. The study was performed to analyze if AIS can diminish the rate of shunt infection. The pathogenic nature of shunt infection in patients with AIS systems and those without antibiotic impregnated shunts (non-AIS) was compared. Methods Over a period of 24 months in the Department of Neurosurgery at University Hospital of Tübingen shunt surgery was performed in 258 patients. In 86 patients AIS systems were implanted. Shunt catheters were commercially impregnated with clindamycin and rifampicin. Analysis of the clinical data included sex, age, classification of hydrocephalus, shunt types and risk factors for shunt infection [age (< 1 year and > 80 years), prematurely born patients, external ventricular drainage, former shunt infection, former systemic infection, disturbance of consciousness, former radiation-/chemotherapy]. Infection rates and underlying bacterial pathogens of patients with AIS were compared to patients with implanted non-AIS systems (172 patients). Results AIS and non-AIS patients did not differ in sex, etiology of hydrocephalus and the shunt type. In the AIS group 72 out of 86 patients had at least one risk factor (83.7 %), compared to 126 patients in the non-AIS group (73.3 %). There was no significant difference between the two groups (p = 0.0629; Fisher's exact test). In patients with no risk factors, only one patient with non-AIS suffered from shunt infection. In patients with one or more risk factors the rate for shunt infection was 7.14 % in patients with non-AIS and 6.94 % in patients with AIS. Former shunt infection (p = 0.0124) was related to higher risk for shunt infection. The use of AIS had therefore no significant advantage (p = 0.8611; multiple logistic regression). Significantly related to a shunt infection was the number of shunt surgeries. 190 interventions in the AIS group (2.21 interventions per patient) and 408 in the non-AIS group (2.37 interventions per patient) had been performed (p = 0.3063; Wilcoxon). There was no shunt infection in the group of patients on whom only one shunt surgery was performed. In patients with at least two shunt surgeries the infection rate was 9%. The infection rate in AIS patients was 5/52 (9.6 %) and in the non-AIS 10/114 (8.77 %), (p = 1.0; Fisher's exact test). Staphylococcus epidermidis was the most frequent pathogen for shunt infection. Fourteen out of 15 infections occurred within the first 6 months of surgery. The most frequent pathogen for shunt infection was S. epidermidis. No toxic or allergic complications were seen using the AIS shunt systems. The presented data show a remarkably low infection rate of 5.8 % in the non-AIS group compared to other studies which demonstrated a significant decrease in the infection rate by AIS. Conclusion AIS did not significantly reduce shunt infection in hydrocephalus patients in the presented study. In the AIS group three patients suffered from shunt infections caused by skin ulceration or neurosurgical procedures with exposure of the cerebrospinal liquor after shunt implantation. AIS was not developed to prevent infection in such cases, therefore an advantage of AIS can not be excluded. In view of the presented data and the small number of reported studies a prospective randomized multicenter study is required. PMID:17488498
Paulsen, Anne Henriette; Lundar, Tryggve; Lindegaard, Karl-Fredrik
2015-12-01
Treatment for hydrocephalus has not advanced appreciably since the advent of CSF shunts more than 50 years ago. The outcome for pediatric patients with hydrocephalus has been the object for several studies; however, much uncertainty remains regarding the very long term outcome for these patients. Shunting became the standard treatment for hydrocephalus in Norway during the 1960s, and the first cohorts from this era have now reached middle age. Therefore, the objective of this study was to review surgical outcome, mortality, social outcome, and health-related quality of life in middle-aged patients treated for hydrocephalus during childhood. Data were collected in all patients, age 14 years or less, who required a CSF shunt during the years 1967-1970. Descriptive statistics were assessed regarding patient characteristics, surgical features, social functioning, and work participation. The time and cause of death, if applicable, were also determined. Kaplan-Meier survival estimates were used to determine the overall survival of patients. Information regarding self-perceived health and functional status was assessed using the 36-Item Short Form Health Survey (SF-36) and the Barthel Index score. A total of 128 patients were included in the study, with no patient lost to follow-up. Of the 128 patients in the study, 61 (47.6%) patients died during the 42-45 years of observation. The patients who died belonged to the tumor group (22 patients) and the myelomeningocele group (13 patients). The mortality rate was lowered to 39% if the patients with tumors were excluded. The overall mortality rates at 1, 2, 10, 20, and 40 years from time of initial shunt insertion were 16%, 24%, 31%, 40%, and 48% respectively. The incidence of shunt-related mortality was 8%. The majority of children graduated from a normal school (67%) or from a school specializing in education for physically handicapped children (20%). Self-perceived health was significantly poorer in 6 out of 8 domains assessed by SF-36 as compared with the background population. Functional status among the survivors varied greatly during the follow-up period, but the majority of patients were self-dependent. A total of 56% of the patients were socially independent, and 42% of the patients were employed. Approximately half of the patients are still alive. During the 42-45 year follow-up period, the mortality rate was 48%. Two deaths were due to acute shunt failure, and at least 8% of the deaths were shunt related (probable or late onset). The morbidity in middle-aged individuals treated for pediatric hydrocephalus is considerable. The late mortality rate was low, but not negligible. Twelve patients died during the last 2 decades, 1 of whom died because of acute shunt failure. Although the shunt revision rate was decreasing during the study period, many patients required shunt surgery during adulthood. Forty-one revisions in 21 patients were performed during the last decade. Thus, there is an obvious need for life-long follow-up in these patients.
Compensatory parameters of intracranial space in giant hydrocephalus.
Cieślicki, Krzysztof; Czepko, Ryszard
2009-01-01
The main goal of the present study is to examine compensatory parameters of intracranial space in giant hydrocephalus. We also assess the early and late outcome and analyse complications in shunted cases. Nine cases of giant hydrocephalus characterised by the value of Evans ratio > 0.5, ventricular index > 1.5, and the width of the third ventricle > 20 mm were considered. Using the lumbar infusion test and developed software we analysed the intracranial compensatory parameters typical for hydrocephalus. Based on the Marmarou model, the method depended on a repeated search for the best fitting curve corresponding to the progress of the test was used. Eight out of nine patients were therefore shunted. Patients were followed up for 9 months. Five out of eight shunted patients undoubtedly improved in a few days after surgery (62%). Complications (subdural hygromas/haematomas and intracerebral haematoma) developed in 5 (62%) cases in longer follow-up. A definite improvement was noted in 4 out of 8 operated cases (50%). To get the stable values of compensatory parameters, the duration of the infusion test must at least double the inflexion time of the test curve. All but one considered cases of giant hydrocephalus were characterized by lack of intracranial space reserve, significantly reduced rate of CSF secretion and by various degrees of elevated value of the resistance to outflow. Due to the significant number of complications and uncertain long-term improvement, great caution in decision making for shunting has to be taken.
Multiple acquired portosystemic shunts secondary to primary hypoplasia of the portal vein in a cat.
Sugimoto, Satoko; Maeda, Shingo; Tsuboi, Masaya; Saeki, Kohei; Chambers, James K; Yonezawa, Tomohiro; Fukushima, Kenjiro; Fujiwara, Reina; Uchida, Kazuyuki; Tsujimoto, Hajime; Matsuki, Naoaki; Ohno, Koichi
2018-06-06
A 6-year 5-month-old spayed female Scottish Fold cat presented with a one-month history of gait abnormalities, increased salivation, and decreased activity. A blood test showed hyperammonemia and increased serum bile acids. Imaging tests revealed multiple shunt vessels indicating acquired portosystemic shunt. Histopathologic analysis of liver biopsy showed features consistent with liver hypoperfusion, such as a barely recognizable portal vein, increased numbers of small arterioles, and diffuse vacuolar degeneration of hepatocytes. These findings supported the diagnosis of primary hypoplasia of the portal vein/microvascular dysplasia, (PHPV/MVD). To our knowledge, this is the first case of feline PHPV/MVD that developed multiple acquired portosystemic shunts and presented with hepatic encephalopathy.
Aoki, N
1991-06-01
A 52-year-old male underwent lumboperitoneal shunting after external decompressive craniectomy. His postoperative course was accompanied by remarkable displacement of the intracranial structures to the opposite side of craniectomy. This phenomenon, probably caused by the siphon effect of cerebrospinal fluid shunting, resolved after cranioplasty. This observation provides the evidence casting doubt on the presence of the siphon effect due to atmospheric pressure in patients without the association of skull defect or open cranial sutures.
Sikorski, Christian W; Curry, Daniel J
2005-01-01
Optimal treatment for hydrocephalus related to Dandy-Walker syndrome (DWS) remains elusive. Patients with DWS-related hydrocephalus often require combinations of shunting systems to effectively drain both the supratentorial ventricles and posterior fossa cyst. We describe an endoscopic technique, whereby a frontally placed, single-catheter shunting system effectively drained the supratentorial and infratentorial compartments. This reduces the complexity and potential risk associated with the combined shunting systems required by so many with DWS-related hydrocephalus. Copyright 2005 S. Karger AG, Basel.
Cabral, Danielle; Beach, Thomas G; Vedders, Linda; Sue, Lucia I; Jacobson, Sandra; Myers, Kent; Sabbagh, Marwan N
2011-01-01
Background Normal pressure hydrocephalus (NPH) is considered potentially treatable with the placement of a cerebrospinal fluid (CSF) shunt. Yet, the procedure has had variable success, particularly with respect to improving the cognitive impairment in NPH. The presence of neurologic co-morbidities, particularly Alzheimer's Disease (AD), may contribute to shunt responsiveness. Uncovering the extent to which AD and NPH co-occur has implications for diagnosis and treatment of NPH. Autopsy studies of patients with NPH during life would elucidate the frequency of such co-morbidities. Methods We conducted a search of the Sun Health Research Institute Brain Donation Program database between 1/1/1997 and 4/1/09 to identify all cases with neuropathologic evidence of dementia as well as those cases of clinically diagnosed NPH. We reviewed the medical records and brain findings of each NPH case. Results Of the 761 cases autopsied over the study interval, 563 cases were found to have neuropathological evidence meeting criteria for a dementing illness. AD was found exclusively in 313/563 (56%) cases with 94/563 cases having a secondary diagnosis of dementia. We identified 9/761 cases with a clinical diagnosis of NPH, all nine cases were among the 563 cases with neuropathology of dementing illness at autopsy, representing 1.6% (9/563). Upon review of brain autopsy reports, 8/9 (89%) cases were found to have AD and 1/9 (11%) had progressive supranuclear palsy. Review of the medical records of the nine NPH cases revealed the following clinical co-morbidities: 5/9 with AD; 1/9 with Parkinson's Disease (PD); 1/9 with Mild Cognitive Impairment (MCI); 1/9 with seizure disorder. Conclusions Given the findings of our study, we support the AD-NPH theory and posit that AD is a common pathological co-morbidity in the setting of NPH and may preclude cognitive improvement post-shunt placement. This may have influence on selection of cases for shunting in the future. PMID:21723206
Infant hydrocephalus in sub-Saharan Africa: the reality on the Tanzanian side of the lake.
Santos, Maria M; Rubagumya, Derick K; Dominic, Imani; Brighton, Amos; Colombe, Soledad; O'Donnell, Philip; Zubkov, Micaella R; Härtl, Roger
2017-11-01
OBJECTIVE Infant hydrocephalus is estimated to affect more than 100,000 new infants each year in sub-Saharan Africa (SSA). Bugando Medical Centre (BMC), a government-funded and patient cost-shared referral center, serves over 13 million people in the Lake and Western regions of Tanzania. The goals of this study were to characterize the infant population affected by hydrocephalus who presented to BMC and were treated with a ventriculoperitoneal shunt (VPS) to determine the rate of early complications associated with this surgical procedure and to assess its potential risk factors. METHODS Data were prospectively collected from all patients less than 1 year of age who, over a period of 7 months, were diagnosed with hydrocephalus and admitted to BMC for insertion of a primary VPS. Demographic data, maternal history, preoperative studies, surgical procedure, and surgical complications developing by the time of the first follow-up visit were analyzed. Risk factors associated with the surgical complications were determined. RESULTS During the 7-month study period, 125 infants eligible for the study were included in the analysis. Overall, 75% were younger than 6 months of age, and 56% were males. Only 7% of mothers had a gestational ultrasound, 98% did not receive preconception folic acid, and 25% delivered their child at home. In most patients with hydrocephalus the etiology was uncertain (56%), and other patients had postinfectious (22.4%) or myelomeningocele-associated (16%) hydrocephalus. Patients' mean head circumference on admission was 51.4 ± 6.3 cm. Their median age at shunt surgery was 137 days, and 22.4% of the patients were operated on without having undergone radiological assessment. The majority of shunts were placed in a right parietooccipital location. Thirteen patients had undergone a previous intraventricular endoscopic procedure. Overall, at least one surgical complication was found in 33.6% of patients up to the first follow-up assessment (median follow-up time of 70 days); shunt infection was the most common complication. The postoperative mortality rate was 9%. The risk factors associated with early surgical complications were tumor-related etiology, larger head circumference, and postoperative hospital stays of greater duration. CONCLUSIONS In a region of the continent where most infant hydrocephalus cases had an uncertain etiology, most patients presented to the hospital in a late stage, with no prenatal diagnosis and with large head circumferences. Standard preoperative investigations were not uniformly performed, and the surgical complications, led by VPS infection, were disturbingly high. Younger patient age, previous endoscopic procedure, surgeon involved, and cranial location of the VPS had no statistical relation to the surgical complications. This study shows that the positive results previously reported by SSA mission hospitals, subspecialized in pediatric neurosurgery, are still not generalizable to every hospital in East Africa. To improve maternal and neonatal care in the Lake region of Tanzania, the development of a fluxogram to determine hydrocephalus etiology, a strict perioperative protocol for VPS insertion, and an increase in the number of endoscopic procedures are recommended to BMC.
Improvised external ventricular drain in neurosurgery: A Nigerian tertiary hospital experience.
Ojo, O A; Asha, M A; Bankole, O B; Kanu, O O
2015-01-01
The most common type of hydrocephalus in developing countries is post infective hydrocephalus. Infected cerebrospinal fluid (CSF) however cannot be shunted for the reason that it will block the chamber of the ventriculo-peritoneal (VP) shunt due to its high protein content. In centers where standard external ventricular drain (EVD) sets are not available, improvised feeding tube can be used. The main focus of this study is to encourage the use of improvised feeding tube catheters for EVD when standard sets are not available to improve patients' survival. This was a prospective study. Consecutive patients with hydrocephalus that cannot be shunted immediately for high chances of shunt failure or signs of increasing intracranial pressure were recruited into the study. Other inclusion criteria were preoperative brain tumor with possibility of blocked CSF pathway and massive intraventricular hemorrhage necessitating ventricular drainage as a salvage procedure. Standard EVD set is not readily available and too expensive for most of the parents to afford. Improvised feeding tube is used to drain/divert CSF using the standard documented procedure for EVD insertion. Outcome is measured and recorded. A total of 28 patients were recruited into the study over a time frame of 2 years. There were 19 (67.9%) male and 9 (32.1%) females with a ratio of about 2:1. Age ranges varied from as low as 7 days to 66 years. The median age of the study sample was 6.5 months while the mean was 173.8 months. Duration of EVD varied from 2 days to 11 days with a median of 7 while the average was 6 days. Eventual outcome following the procedure of EVD showed that 19 (67.9%) survived and were discharged either to go home or to have VP shunt afterwards while 8 (28.6%) of the patients died. External ventricular drain can and should be done when it is necessary. Potential mortalities could be reduced by the improvised drainage using a standard feeding tube as described.
Guizilini, Solange; Alves, Daniel F; Bolzan, Douglas W; Cancio, Andreia S A; Regenga, Marisa M; Moreira, Rita S L; Trimer, Renata; Gomes, Walter J
2014-09-01
The aim of this trial was to compare functional capacity, pulmonary shunt fraction and clinical outcomes between patients undergoing pleurotomy with a pleural drain inserted in the sub-xyphoid position and patients with a pleural drain placed in the intercostal position after off-pump coronary artery bypass surgery. Patients were randomized into two groups according to the pleural drain site: Group II (n = 33 intercostal pleural drain); and Group SI (n = 35 sub-xyphoid pleural drain). Functional capacity was assessed by the distance covered on the 6-min walking test performed preoperatively and on postoperative day (POD) 5; in addition, pulmonary function test was determined preoperatively and on POD 1 and 5. Pulmonary shunt fraction was evaluated preoperatively and on POD 1, and clinical outcomes were recorded throughout the study. Group SI had better preservation of lung volumes and capacities in POD compared with Group II (P <0.05). Pulmonary shunt fraction increased in both groups postoperatively; however, Group SI showed a smaller pulmonary shunt fraction (0.26 ± 0.04 vs 0.21 ± 0.04%; P = 0.0014). Functional capacity was significantly reduced in both groups on POD 5; however, Group SI showed better preservation of functional capacity (P = 0.0001). Group SI had better postoperative clinical results, with lower incidence of atelectasis and pleural effusion (P <0.05), lower pain scores (P <0.0001), and shorter orotracheal intubation and hospitalization lengths (P <0.001). Sub-xyphoid pleural drain determined better functional capacity and exercise tolerance with a smaller pulmonary shunt fraction and improved clinical outcomes compared with intercostal pleural drainage after off-pump coronary artery bypass surgery. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Caron, C.; Luneau, C.; Gervais, M. H.; Plante, G. E.; Sanchez, G.; Blain, G.
1979-01-01
In patients with cerebrospinal fluid internal shunts, immune complex glomerulonephritis sometimes develops. Of two new cases the first was classic, while the second was in an adult who had had a ventriculoatril shunt for 8 years; furthermore, the patient had acute renal failure and is the first to have been reported to have Peptococcus septicemia. Shunt glomerulonephritis is characterized by the following: (a) its occurrence following, most often, Staphylococcus albus infection in a patient who usually has a ventriculoatrial shunt; (b) transitory improvement of the symptoms by antibiotherapy only; and (c) full recovery if the prosthesis is removed. Laboratory studies show a low serum concentration of the C3 component of complement, the presence of cryoglobulins and a positive rheumatoid factor test. These abnormalities are reversible with removal of the prosthesis. Optical microscopy of a renal biopsy specimen in the two cases showed cellular proliferation of the glomerular tuft, electron microscopy demonstrated subepithelial deposits and immunofluorescent studies revealed intramembranous and intramesangial immune complexes. These features are similar to those observed in experimental nephritis induced in animals by foreign protein. Images FIG. 3 FIG. 4 FIG. 5 FIG. 6 FIG. 7 PMID:436034
Histological findings of failed gold micro shunts in primary open-angle glaucoma.
Agnifili, Luca; Costagliola, Ciro; Figus, Michele; Iezzi, Giovanna; Piattelli, Adriano; Carpineto, Paolo; Mastropasqua, Rodolfo; Nardi, Marco; Mastropasqua, Leonardo
2012-01-01
To describe the histological features of failed gold micro shunts (GMS) in unsuccessful implantations for refractory primary open-angle glaucoma (POAG). This was an interventional case series study. Five eyes of five glaucomatous patients with unsuccessful GMS implantation underwent shunt removal. Each device was sectioned into three portions: proximal or anterior chamber (AC) portion, middle or scleral portion and distal or suprachoroidal (SC) portion. The histological analysis was performed throughout the whole extent of the shunt, describing both the inner spaces and the outer surface. At the moment of removal all devices were correctly located into the SC space and in AC, with the exception of a case presenting corneal endothelial contact. The mean intra-ocular pressure before GMS removal was 30.4 ± 5.3 mmHg, and the mean time of GMS removal after implantation was 6.8 ± 2.5 months. No significant histological differences were documented among the five analyzed devices. The main feature was the presence of a thick connective capsule-like reaction surrounding both the proximal and distal ends and invading the posterior and anterior grid holes, whereas a more loosely arranged connective tissue was observed within the inner channels. Signs of surface fibrosis of the middle-scleral portion and inflammatory cell infiltration of the device were not documented in any of the cases. Failed GMS implantations presented connective tissue filling all the inner spaces and creating a thick fibrotic capsule surrounding the ends of the device. This modification isolated the GMS from the AC and SC space, impeding aqueous flows throughout the shunt.
Chatzidakis, Emmanuel M; Barlas, George; Condilis, Nicolas; Bouramas, Dimos; Anagnostopoulos, Demetrios; Volikas, Zacharias; Simopoulos, Konstantinos
2008-01-01
The aim of this study is to find out the correlation of the ventricular size of the brain, as it is estimated using brain computed tomography (CT) scan indexes in patients with normal pressure hydrocephalus (NPH), to: a) the clinical symptoms, and b) the results of cerebrospinal fluid (CSF) shunting procedures. We looked for any predictive value in the estimation of brain CT scan indexes, in patients as above, in whom a shunt is going to be placed. It is well known that it is very difficult to decide who is going to improve after shunting. We studied 40 cases of patients with the diagnosis "NPH" in whom the ventricular shunts were placed. Every symptom (motor disturbance, deficit of memory, incontinence) was separately evaluated preoperatively. The outcome of shunting was also evaluated and the patients were graded. The following CT scan indexes were estimated from the preoperative CT scans of the brain in every case: the ventricle-brain ratio (VBR), the bi-caudate and bi-frontal ratios, the third ventricle-Sylvian fissure (3V-SF) ratio, and the four largest cortical gyri. The method we have used for statistics is "one way analysis of variance", correlating the CT scan indexes to the symptoms of the patients preoperatively, and the outcome of them postoperatively. The main conclusion is that the size of the lateral ventricles of the brain preoperatively is not correlated to the outcome after CSF shunting surgery, but it is correlated to the symptoms of NPH preoperatively.
Oushy, Soliman; Parker, Jonathon J; Campbell, Kristen; Palmer, Claire; Wilkinson, Corbett; Stence, Nicholas V; Handler, Michael H; Mirsky, David M
2017-11-01
OBJECTIVE Placement of a cerebrospinal fluid diversion device (i.e., shunt) is a routine pediatric neurosurgical procedure, often performed in the first weeks of life for treatment of congenital hydrocephalus. In the postoperative period, shunt placement may be complicated by subdural, catheter tract, parenchymal, and intraventricular hemorrhages. The authors observed a subset of infants and neonates who developed multifocal intraparenchymal hemorrhages (MIPH) following shunt placement and sought to determine any predisposing perioperative variables. METHODS A retrospective review of the electronic medical record at a tertiary-care children's hospital was performed for the period 1998-2015. Inclusion criteria consisted of shunt placement, age < 30 days, and available pre- and postoperative brain imaging. The following data were collected and analyzed for each case: ventricular size ratios, laboratory values, clinical presentation, shunt and valve type, and operative timing and approach. RESULTS A total of 121 neonates met the inclusion criteria for the study, and 11 patients (9.1%) had MIPH following shunt placement. The preoperative frontal and occipital horn ratio (FOR) was significantly higher in the patients with MIPH than in those without (0.65 vs 0.57, p < 0.001). The change in FOR (∆FOR) after shunt placement was significantly greater in the MIPH group (0.14 vs 0.08, p = 0.04). Among neonates who developed MIPH, aqueductal stenosis was the most common etiology (45%). The type of shunt valve was associated with incidence of MIPH (p < 0.001). Preoperative clinical parameters, including head circumference, bulging fontanelle, and coagulopathy, were not significantly associated with development of MIPH. CONCLUSIONS MIPH represents an underrecognized complication of neonatal shunted hydrocephalus. Markers of severity of ventriculomegaly (FOR) and ventricular response to CSF diversion (∆FOR) were significantly associated with occurrence of MIPH. Choice of shunt and etiology of hydrocephalus were also significantly associated with MIPH. After adjusting for corrected age, etiology of hydrocephalus, and shunt setting, the authors found that ∆FOR after shunting was still associated with MIPH. A prospective study of MIPH prevention strategies and assessment of possible implications for patient outcomes is needed.
Daily tadalafil for the chronic phase of stuttering priapism: a case report.
Massenio, Paolo; D'Altilia, Nicola; Sanguedolce, Francesca; Carrieri, Giuseppe; Cormio, Luigi
2018-05-31
Recurrent (stuttering) ischemic priapism is a challenging clinical condition. Frequent recurrences result in frequent hospital admissions whereas treatment with a shunting procedure often results in erectile dysfunction. A 22-year-old man with stuttering idiopathic priapism developed erectile dysfunction (IIEF-5 score 12) following a Winter's shunt; he was given tadalafil, 5 mg/daily, for 6 months. This treatment resulted in progressive restoration of erectile function in the 6 months following the shunt as well as in preventing recurrence of priapic episodes over a 24-month follow-up. This is the first report in literature of chronic treatment of stuttering priapism with a phosphodiesterase-5 inhibitor being able not only to prevent recurrent priapic episodes but also to restore erectile function following a Winter's shunt.
Mallmann, M R; Geipel, A; Bludau, M; Matil, K; Gottschalk, I; Hoopmann, M; Müller, A; Bachour, H; Heydweiller, A; Gembruch, U; Berg, C
2014-10-01
To assess the incidence of complications among a relatively large cohort of fetuses with bronchopulmonary sequestration (BPS) and the success of two different intrauterine treatment modalities. All cases with a prenatal diagnosis of BPS detected in a 10-year period (2002-2011) in two tertiary referral centers were reviewed retrospectively for intrauterine course and outcome. Up to May 2010 severe pleural effusions were treated with pleuroamniotic shunting. Thereafter, they were treated with ultrasound-guided laser coagulation of the feeding artery. A total of 41 fetuses with BPS were included in the study. In 29 (70.7%) there was no pleural effusion or hydrops and they were treated conservatively. In 19/29 (65.5%) there was partial or complete regression of the lesion during the course of pregnancy. All were born alive (median age at delivery, 38.3 (interquartile range (IQR), 34.0-39.6) weeks) and 16 (55.2%) required sequestrectomy. Intrauterine intervention was performed in all 12 (29.3%) fetuses with pleural effusion. Seven fetuses were treated with pleuroamniotic shunting. One fetus with severe hydrops died in utero. There was no complete regression in any case of BPS in this group. Six infants were born alive (median age, 37.2 (IQR, 30.3-37.4) weeks), of which five (83.3%) required sequestrectomy. Five fetuses were treated with laser ablation of the feeding vessel. In all cases of BPS there was regression after laser ablation. All infants were delivered at term (median age, 39.1 (IQR, 38.0-40.0) weeks). One (20.0%) neonate required sequestrectomy after birth. Following intrauterine shunt placement complete regression of the lesion was significantly less frequent (0/7 (0%) with shunt placement vs 4/5 (80%) with intrafetal laser treatment) and gestational age at birth was significantly lower, compared to treatment with intrafetal laser. Complete regression of the lesion was also significantly more frequent in the laser group compared to cases without intervention. In the absence of pleural effusion, the likelihood of spontaneous regression of BPS is high and the prognosis is therefore favorable. In cases with massive pleural effusion, treatment by laser ablation of the feeding vessel seems to be more effective than is pleuroamniotic shunting, with fewer complications. It might also reduce the need for postnatal surgery. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Laparoscopic treatment of abdominal complications following ventriculoperitoneal shunt
Grigorean, VT; Onose, G; Popescu, M; Strambu, V; Sandu, AM
2009-01-01
The aim of this study is the evaluation of laparoscopic treatment in abdominal complications following ventriculoperitoneal (VP) shunt. Methods: We report a retrospective study including 17 patients with abdominal complications secondary to VP shunt for hydrocephalus, laparoscopically treated in our department, between 2000 and 2007. Results: Patients' age ranged from 1 to 72 years old (mean age 25.8 years old). Male: female ratio was 1.4. Abdominal complications encountered were: shunt disconnection with intraperitoneal distal catheter migration 47.05% (8/17), infections 23.52% (4/17) such as abscesses and peritonitis, pseudocysts 11.76% (2/17), CSF ascites 5.88% (1/17), inguinal hernia 5.88% (1/17), and shunt malfunction due to excessive length of intraperitoneal tube 5.88% (1/17). Free–disease interval varies from 1 day to 21 years, depending on the type of complication, short in peritoneal irritation syndrome and abscesses (days) and long in ascites, pseudocysts(months– years). Laparoscopic treatment was: extraction of the foreign body in shunt disconnection with intraperitoneal distal catheter migration, evacuation, debridement, lavage and drainage for pseudocysts, abscess and peritonitis, shortening of the tube in shunt malfunction due to excessive length of intraperitoneal tube a nd hernioraphy. One diagnostic laparoscopy was performed in a peritoneal irritation syndrome, which found only CSF ascites. There were no conversions to open surgery. The overall mortality was of 5.88% and postoperative morbidity was of 11.76%. In 7 patients operated for abscesses, peritonitis, pseudocysts, and CSF ascites the shunting system was converted in to a ventriculocardiac shunt. Conclusions: Abdominal complication following VP shunt can be successfully performed laparoscopically. Abdominal surgery required, in selected cases, the repositioning of the distal catheter, frequently as a ventriculocardiac shunt. There are abdominal complications with no indication of surgery, like peritoneal irritation syndrome and CSF ascites. Free– disease interval varies from days (peritoneal irritation syndrome, abscesses) to month–years (pseudocyst, ascites), according to type of complication. PMID:20108757
Hruby, Paul M; Poley, Preeti R; Terp, Patricia A; Thorell, William E; Margalit, Eyal
2013-01-01
To describe a case of intravitreal silicone oil (SO) migration into the cerebral ventricles with secondary chronic headaches. Retrospective case report. Chart review. Single patient. A 51-year-old man with a history of proliferative diabetic retinopathy underwent surgery for traction retinal detachment using SO. Postoperatively, he developed elevated intraocular pressure, headaches, and a blind painful eye, which was enucleated. Neuroimaging revealed SO within the cerebral ventricles. Five years after the initial retinal detachment surgery, the patient developed chronic headaches. Lumbar puncture revealed an elevated opening pressure. The headaches were initially managed medically. A ventriculoperitoneal shunt was placed after the headaches persisted, which resulted in their complete resolution at 6 weeks after shunt placement. Ocular hypertension after intravitreal SO placement may play a role in SO intracranial migration. In the case presented, intraventricular SO was the apparent cause of elevated intracranial pressure and headaches. As all published cases of intraventricular SO migration reporting intraocular pressure to this point have described ocular hypertension, careful monitoring of intraocular pressure and aggressive control of ocular hypertension in the presence of intravitreal SO is recommended.
Postprandial hyperinsulinaemic hypoglycaemia secondary to a congenital portosystemic shunt.
Senniappan, Senthil; Pitt, Katherine; Shah, Pratik; Arya, Ved; Jaiswal, Sanjay; Haddad, Munther; Hind, Jonathan; Dhawan, Anil; Davenport, Mark; Hussain, Khalid
2015-01-01
Portosystemic shunts (PSS) are abnormal vascular connections between the portal vein or its tributaries and the systemic vein that allow mesenteric blood to reach the systemic circulation without first passing through the liver. PSS can be associated with various syndromes and can lead to serious complications. We report a rare case of a child with PSS and recurrent hypoglycaemia. A 20-month-old girl with Down's syndrome presented with recurrent hypoglycaemic episodes. She had multiple anomalies including a ventricular septal defect, oesophageal atresia and tracheo-esophageal fistula, gastro-oesophageal reflux, and conjugated hyperbilirubinaemia. The initial investigations suggested hyperinsulinaemic hypoglycaemia (HH). She did not respond to diazoxide. An oral glucose tolerance test suggested postprandial HH. Further vascular imaging showed a side-to-side portocaval shunt (Abernethy malformation) with relative hypoperfusion of the liver. Hypoglycaemia resolved following surgical closure of the portocaval shunt. PSS can rarely be associated with HH, possibly due to lack of insulin degradation in the liver. Surgical closure of the shunt resolves the hypoglycaemia. © 2015 S. Karger AG, Basel.
Congenital Portosystemic Shunt: Our Experience
Timpanaro, Tiziana; Passanisi, Stefano; Sauna, Alessandra; Trombatore, Claudia; Pennisi, Monica; Petrillo, Giuseppe; Smilari, Pierluigi; Greco, Filippo
2015-01-01
Introduction. Congenital portosystemic venous malformations are rare abnormalities in which the portal blood drains into a systemic vein and which are characterized by extreme clinical variability. Case Presentations. The authors present two case reports of a congenital extrahepatic portosystemic shunt (Type II). In the first patient, apparently nonspecific symptoms, such as headache and fatigue, proved to be secondary to hypoglycemic episodes related to the presence of a portosystemic shunt, later confirmed on imaging. During portal vein angiography, endovascular embolization of the portocaval fistula achieved occlusion of the anomalous venous tract. In the second patient, affected by Down's syndrome, the diagnosis of a portosystemic malformation was made by routine ultrasonography, performed to rule out concurrent congenital anomalies. Because of the absence of symptoms, we chose to observe this patient. Conclusions. These two case reports demonstrate the clinical heterogeneity of this malformation and the need for a multidisciplinary approach. As part of a proper workup, clinical evaluation must always be followed by radiographic diagnosis. PMID:25709849
Ventriculoperitoneal shunt infection caused by Bifidobacterium breve.
Suwantarat, Nuntra; Romagnoli, Mark; Wakefield, Teresa; Carroll, Karen C
2014-08-01
Bifidobacterium breve is a rare cause of human infections. Previously, bacteremia and meningitis caused by this organism linked to probiotic use have been reported in a neonate. We report the first case of a ventriculoperitoneal shunt infection caused by B. breve in an adult without a history of probiotic use. Copyright © 2014 Elsevier Ltd. All rights reserved.
Stent Angioplasty of Closed Mesocaval Shunt in a Patient with Budd-Chiari Syndrome
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sancak, Tanzer; Karagulle, Ayse Tuba; Bilgic, Sadik
Budd-Chiari syndrome (BCS) is an uncommon disorder caused by hepatic venous outflow obstruction. It is characterized by ascites, hepatomegaly and abdominal pain. Percutaneous intervention shave recently been used for the treatment of BCS. We present a case of BCS with a closed mesocaval shunt which was reopened with a self-expandable metallic stent.
Platypnea-orthodeoxia syndrome in the right lateral decubitus position: a case report.
Tsuzuki, Ippei; Iigaya, Kamon; Matsubara, Takashi; Takagi, Shunsuke; Inohara, Taku; Ohgino, Yasuyuki; Imafuku, Toshio
2017-04-12
Platypnea-orthodeoxia syndrome is a rare syndrome characterized by dyspnea and hypoxia when the patient is sitting or standing. Here we report a case of platypnea-orthodeoxia syndrome caused by a right hemidiaphragmatic elevation with giant liver cyst that triggered a right-to-left shunt through the patent foramen ovale. This case report is the first presentation of a case secondary to hemidiaphragmatic elevation with giant liver cyst. In addition to this, a malposition of the pacemaker lead could be associated with platypnea-orthodeoxia syndrome in this case. A 91-year-old Japanese woman presented to our hospital with hypoxia of unknown origin. Severe hypoxia and cyanosis were observed only in the right lateral decubitus position. A chest X-ray and computed tomography scan revealed right hemidiaphragmatic elevation, which was probably compressing the right atrium. A transesophageal echocardiogram showed a compressed right atrium and shunt blood flow in both directions: from the left to the right atrium and vice versa. The shunt flow was exacerbated by postural changes from the left to the right lateral decubitus. A transesophageal echocardiogram also confirmed compression of the right atrium due to giant liver cyst and a malposition of the pacemaker lead abnormally placed in the left atrium through patent foramen ovale. We concluded that the cause of hypoxia was platypnea-orthodeoxia syndrome with right-to-left interatrial shunt through patent foramen ovale. Surgical closure of patent foramen ovale was not performed due to the age of our patient, surgical difficulties, and failure to obtain informed consent. For these reasons she was discharged after receiving medical advice about her posture. Platypnea-orthodeoxia syndrome is rare and difficult to diagnose. The present case suggests that hypoxia due to postural changes should be considered a differential diagnosis of platypnea-orthodeoxia syndrome.
Swetapadma, Aleena; Yadav, Anamika
2015-01-01
Many schemes are reported for shunt fault location estimation, but fault location estimation of series or open conductor faults has not been dealt with so far. The existing numerical relays only detect the open conductor (series) fault and give the indication of the faulty phase(s), but they are unable to locate the series fault. The repair crew needs to patrol the complete line to find the location of series fault. In this paper fuzzy based fault detection/classification and location schemes in time domain are proposed for both series faults, shunt faults, and simultaneous series and shunt faults. The fault simulation studies and fault location algorithm have been developed using Matlab/Simulink. Synchronized phasors of voltage and current signals of both the ends of the line have been used as input to the proposed fuzzy based fault location scheme. Percentage of error in location of series fault is within 1% and shunt fault is 5% for all the tested fault cases. Validation of percentage of error in location estimation is done using Chi square test with both 1% and 5% level of significance. PMID:26413088
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozaki, Toshiro, E-mail: ganronbun@amail.plala.or.jp; Seki, Hiroshi; Shiina, Makoto
2009-09-15
The purpose of the present study was to elucidate a method for predicting the intrahepatic arteriovenous shunt rate from computed tomography (CT) images and biochemical data, instead of from arterial perfusion scintigraphy, because adverse exacerbated systemic effects may be induced in cases where a high shunt rate exists. CT and arterial perfusion scintigraphy were performed in patients with liver metastases from gastric or colorectal cancer. Biochemical data and tumor marker levels of 33 enrolled patients were measured. The results were statistically verified by multiple regression analysis. The total metastatic hepatic tumor volume (V{sub metastasized}), residual hepatic parenchyma volume (V{sub residual};more » calculated from CT images), and biochemical data were treated as independent variables; the intrahepatic arteriovenous (IHAV) shunt rate (calculated from scintigraphy) was treated as a dependent variable. The IHAV shunt rate was 15.1 {+-} 11.9%. Based on the correlation matrixes, the best correlation coefficient of 0.84 was established between the IHAV shunt rate and V{sub metastasized} (p < 0.01). In the multiple regression analysis with the IHAV shunt rate as the dependent variable, the coefficient of determination (R{sup 2}) was 0.75, which was significant at the 0.1% level with two significant independent variables (V{sub metastasized} and V{sub residual}). The standardized regression coefficients ({beta}) of V{sub metastasized} and V{sub residual} were significant at the 0.1 and 5% levels, respectively. Based on this result, we can obtain a predicted value of IHAV shunt rate (p < 0.001) using CT images. When a high shunt rate was predicted, beneficial and consistent clinical monitoring can be initiated in, for example, hepatic arterial infusion chemotherapy.« less
The classification based on intrahepatic portal system for congenital portosystemic shunts.
Kanazawa, Hiroyuki; Nosaka, Shunsuke; Miyazaki, Osamu; Sakamoto, Seisuke; Fukuda, Akinari; Shigeta, Takanobu; Nakazawa, Atsuko; Kasahara, Mureo
2015-04-01
Liver transplantation was previously indicated as a curative operation for congenital absence of portal vein. Recent advances in radiological interventional techniques can precisely visualize the architecture of the intrahepatic portal system (IHPS). Therefore, the therapeutic approach for congenital portosystemic shunt (CPS) needs to be reevaluated from a viewpoint of radiological appearances. The aim of this study was to propose the IHPS classification which could explain the pathophysiological characteristics and play a complementary role of a therapeutic approach and management for CPS. Nineteen patients with CPS were retrospectively reviewed. The median age at diagnosis was 6.8 years old. Eighteen of these patients underwent angiography with a shunt occlusion test and were classified based of the severity of the hypoplasia of IHPS. The eighteen cases who could undergo the shunt occlusion test were classified into mild (n=7), moderate (n=6) and severe types (n=5) according to the IHPS classification. The IHPS classification correlated with the portal venous pressure under shunt occlusion, the histopathological findings, postoperative portal venous flow and liver regeneration. Shunt closure resulted in dramatic improvement in the laboratory data and subclinical encephalopathy. Two patients with the severe type suffered from sepsis associated with portal hypertension after treatment, and from the portal flow steal phenomenon because of the development of unexpected collateral vessels. The patients with the severe type had a high risk of postoperative complications after shunt closure in one step, even if the PVP was relatively low during the shunt occlusion test. The IHPS could be visualized by the shunt occlusion test. The IHPS classification reflected the clinicopathological features of CPS, and was useful to determine the therapeutic approach and management for CPS. Copyright © 2015 Elsevier Inc. All rights reserved.
Pulse amplitude of intracranial pressure waveform in hydrocephalus.
Czosnyka, Z; Keong, N; Kim, D J; Radolovich, D; Smielewski, P; Lavinio, A; Schmidt, E A; Momjian, S; Owler, B; Pickard, J D; Czosnyka, M
2008-01-01
There is increasing interest in evaluation of the pulse amplitude of intracranial pressure (AMP) in explaining dynamic aspects of hydrocephalus. We reviewed a large number of ICP recordings in a group of hydrocephalic patients to assess utility of AMP. From a database including approximately 2,100 cases of infusion studies (either lumbar or intraventricular) and overnight ICP monitoring in patients suffering from hydrocephalus of various types (both communicating and non-communicating), etiology and stage of management (non-shunted or shunted) pressure recordings were evaluated. For subgroup analysis we selected 60 patients with idiopathic NPH with full follow-up after shunting. In 29 patients we compared pulse amplitude during an infusion study performed before and after shunting with a properly functioning shunt. Amplitude was calculated from ICP waveforms using spectral analysis methodology. A large amplitude was associated with good outcome after shunting (positive predictive value of clinical improvement for AMP above 2.5 mmHg was 95%). However, low amplitude did not predict poor outcome (for AMP below 2.5 mmHg 52% of patients improved). Correlations of AMP with ICP and Rcsf were positive and statistically significant (N = 131 with idiopathic NPH; R = 0.21 for correlation with mean ICP and 0.22 with Rcsf; p< 0.01). Correlation with the brain elastance coefficient (or PVI) was not significant. There was also no significant correlation between pulse amplitude and width of the ventricles. The pulse amplitude decreased (p < 0.005) after shunting. Interpretation of the ICP pulse waveform may be clinically useful in patients suffering from hydrocephalus. Elevated amplitude seems to be a positive predictor for clinical improvement after shunting. A properly functioning shunt reduces the pulse amplitude.
Post-hemorrhagic hydrocephalus: Recent advances and new therapeutic insights.
Chen, Qianwei; Feng, Zhou; Tan, Qiang; Guo, Jing; Tang, Jun; Tan, Liang; Feng, Hua; Chen, Zhi
2017-04-15
Post-hemorrhagic hydrocephalus (PHH), also referred to as progressive ventricular dilatation, is caused by disturbances in cerebrospinal fluid (CSF) flow or absorption following hemorrhage in the brain. As one of the most serious complications of neonatal/adult intraventricular hemorrhage (IVH), subarachnoid hemorrhage (SAH), and traumatic brain injury (TBI), PHH is associated with increased morbidity and disability of these events. Common sequelae of PHH include neurocognitive impairment, motor dysfunction, and growth impairment. Non-surgical measures to reduce increased intracranial pressure (ICP) in PHH have shown little success and most patients will ultimately require surgical management, such as external ventricular drainage and shunting which mostly by inserting a CSF drainage shunt. Unfortunately, shunt complications are common and the optimum time for intervention is unclear. To date, there remains no comprehensive strategy for PHH management and it becomes imperative that to explore new therapeutic targets and methods for PHH. Over past decades, increasing evidence have indicated that hemorrhage-derived blood and subsequent metabolic products may play a key role in the development of IVH-, SAH- and TBI-associated PHH. Several intervention strategies have recently been evaluated and cross-referenced. In this review, we summarized and discussed the common aspects of hydrocephalus following IVH, SAH and TBI, relevant experimental animal models, clinical translation of in vivo experiments, and potential preventive and therapeutic targets for PHH. Copyright © 2017 Elsevier B.V. All rights reserved.
[Suprasellar arachnoid cyst--report of a case (author's transl)].
Takahashi, T; Kawai, S; Kaminoh, T; Hiramatsu, K; Maekawa, M; Yuasa, T; Miyamoto, N; Hattori, Y
1982-04-01
A 4-year-old boy with suprasellar arachnoid cyst was reported. At the age of 30-month-old his aunt was aware of his squint. During the observation by ophthalmologists from the age of 1y. to 3y., enlargement of the head and impairment of the visual acuity were manifested. Cranial CT scan revealed the enlargement of the ventricular system and a round low density area located superior to the sella. Absorption coefficient of the lesion was similar to that of the cerebrospinal fluid. No abnormal contrast enhancement was seen. Examination revealed the head circumference of 53.3 cm larger than doubled standard deviation, the right external strabismus, impaired vision (R:0.03, L:0.3) and optic atrophy but no other neurological signs. Cerebral angiography showed suprasellar mass lesion. After the ventriculography with water-soluble contrast medium, V-P shunt operation was performed and then the patient was transferred to the CT room. CSF enhanced CT scan showed no communication between the ventricles and the cyst. By frontotemporal approach, microsurgical removal of the cystwall was performed and the histological diagnosis was arachnoid membrane. Several days after the operation, bilateral subdural effusion was seen on CT scan and was treated with bilateral S-P shunt and the removal of V-P shunt. Follow up CT scan disclosed the disappearance of the subdural effusion and the suprasellar cyst. The visual acuity was improved well and the endocrinological study was normal. Analysis of the 45 reported cases of suprasellar arachnoid cyst suggested that direct removal of the cyst wall is better than the V-P shunt operation and the cyst shunting is advisable for repeat recurrence of the cyst. Removal of the ventricular shunting system may be effective for the prevention of the subdural effusion as a complication after direct operation.
Chrastina, Jan; Novák, Zdeněk; Zeman, Tomáš; Feitová, Věra; Hrabovský, Dušan; Říha, Ivo
2018-05-01
Posttraumatic hydrocephalus (PTH) and posthemorrhagic hydrocephalus (PHH) were previously considered not suitable for neuroendoscopic treatment. New hydrocephalus theories support possible successful neuroendoscopy in such patients. This study presents the results of neuroendoscopy in PTH and PHH with a background analysis. From 130 hydrocephalic patients after neuroendoscopic surgeries, 35 cases with PTH (n = 11) or PHH (n = 24; acute: n = 9, subacute: n = 10, chronic: n = 5) were found. The success rate (Glasgow Outcome Scale [GOS] score 4 or 5 without shunt) and clinical outcome (GOS score) of endoscopic third ventriculostomy (ETV) were analyzed. During the study period, 34 patients had ventriculoperitoneal shunts implanted, including 2 PTH and 5 PHH patients (all chronic). The success rate of ETV in PTH was 54.5%. In acute PHH, the success rate was 33.3%, 42.8% after excluding devastating hematomas. A post-ETV shunt was implanted in 1 patient (massive subarachnoid hemorrhage [SAH]) with final GOS score of 5. In subacute cases, the ETV success rate was 40% (no post-ETV shunts). In chronic PHH, only 1 patient with a GOS score of 5 was shunt-free (20%). The cause of ETV failure was massive SAH. Low final GOS score was caused by the extent of intracerebral bleeding or extracranial problems. The main indications for primary shunt implantation in PTH and PHH were infectious complications. The rate of good outcomes was 0% in PTH and 40% in PHH. The best results of neuroendoscopy were achieved in PTH and acute PHH. ETV failures were associated with massive SAH; arachnoid cistern blockage and scarring precludes ETV success. Copyright © 2018 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takao, Hidemasa, E-mail: takaoh-tky@umin.ac.jp; Shibata, Eisuke; Ohtomo, Kuni
A case of multiple hepatocellular carcinomas with a severe intrahepatic arterioportal shunt that was successfully embolized with n-butyl-2-cyanoacrylate with coaxial double-balloon occlusion prior to transcatheter arterial chemoembolization is presented. A proximal balloon positioned at the proper hepatic artery was used for flow control, and a coaxial microballoon, positioned in the closest of three arterial feeding branches to the arterioportal shunt, was used to control the delivery of n-butyl-2-cyanoacrylate. This coaxial double-balloon technique can prevent proximal embolization and distal migration of n-butyl-2-cyanoacrylate and enable precise control of the distribution of n-butyl-2-cyanoacrylate. It could also be applicable to n-butyl-2-cyanoacrylate embolization for othermore » than intrahepatic arterioportal shunt.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Bezzi, Mario; Bruni, Antonio
2011-02-15
We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findingsmore » and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.« less
Abernethy malformation: a case report
2012-01-01
Background Abernethy malformation is a very rare congenital vascular malformation defined by diversion of portal blood away from liver. It is commonly associated with multiple congenital anomalies. We present a case of Abernethy malformation, without associated congenital anomalies from India. Case presentation A 5-year-old female child presented with short history of jaundice. A provisional diagnosis of acute viral hepatitis was made in view of clinical presentation and local endemicity of viral hepatitis A. Persistence of jaundice on follow up after 4 weeks led to detailed investigations. Ultrasound and doppler study of abdomen revealed drainage of portal vein into inferior vena cava. CT angiography was performed which confirmed the diagnosis of Type 1 b Abernethy malformation without associated major anomalies. We discuss the common clinical presentations, associated anomalies, diagnostic workup and treatment options of this disorder. Conclusion The treatment of the patients with congenital porto-systemic shunts depends on the site of the shunt, associated congenital anomalies and the extent of liver damage but the prognosis depends on the complications irrespective of anatomical type. However, the extent of associated abnormalities should not deter paediatricians to refer patients for treatment. Whenever possible closure of the shunt should be advised for cure or to prevent complications. Only symptomatic type I patients with absence of possibility to close the shunt may require liver transplant. Long-term follow-up is indicated for all patients. PMID:22642663
Toib, Amir; Goldstein, Seth B; Khanna, Geetika; Canter, Charles E; Lee, Caroline K; Balzer, David T; Singh, Gautam K
2012-01-01
We describe a case of an infant with a single ventricle physiology, who presented with spontaneous microbubbles originating from her inferior vena cava. Imaging revealed a persistent patent ductus venosus, leading to a portosystemic shunt, streaming the microbubbles into the heart. We discuss the possible mechanisms for this rare phenomenon in a child. © 2011 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanaka, Toshihiro, E-mail: toshihir@bf6.so-net.ne.jp; Guenther, Rolf W., E-mail: guenther@rad.rwth-aachen.de; Isfort, Peter, E-mail: isfort@hia.rwth-aachen.de
Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction is an important problem after creation of shunts. Most commonly, TIPS recanalization is performed via the jugular vein approach. Occasionally it is difficult to cross the occlusion. We describe a hybrid technique for TIPS revision via a direct transhepatic access combined with a transjugular approach. In two cases, bare metal stents or polytetrafluoroethylene (PTFE)-covered stent grafts had been placed in TIPS tract previously, and they were completely obstructed. The tracts were inaccessible via the jugular vein route alone. In each case, after fluoroscopy or computed tomography-guided transhepatic puncture of the stented segment of themore » TIPS, a wire was threaded through the shunt and snared into the right jugular vein. The TIPS was revised by balloon angioplasty and additional in-stent placement of PTFE-covered stent grafts. The patients were discharged without any complications. Doppler sonography 6 weeks after TIPS revision confirmed patency in the TIPS tract and the disappearance of ascites. We conclude that this technique is feasible and useful, even in patients with previous PTFE-covered stent graft placement.« less
Shooman, David; Vajramani, Girish V; Davidson, Jennifer; Sparrow, Owen C
2010-05-01
High cerebrospinal fluid (CSF) protein is a recognised association of optic pathway gliomas. This can occlude ventriculoperitoneal (VP) shunt catheters or external ventricular drains (EVD). We describe an 8-year-old boy with an optic pathway glioma, who had frequent episodes of a blocked VP shunt and EVD due to high CSF protein level. This responded favourably to repeated urokinase instillation into the catheter lumen. We present the course of treatment and the method of administration and review the literature behind thrombolytic therapy for occluded catheter devices. Intrathecal urokinase was effective in unblocking the EVD and lysing the protein clots within the ventricle. We found no previously published cases of intrathecal urokinase for this problem. This novel intervention seemed promising as a safe and effective means of maintaining EVD patency in cases complicated by excessive protein loads in CSF and hydrocephalus.
Armored brain in patients with hydrocephalus after shunt surgery: review of the literatures.
Taha, Mahmoud M
2012-01-01
Armored brain or chronic calcified subdural hematoma is a rare complication of cerebrospinal fluid diversion with few cases reported in the literature. Seventeen patients with this pathology have been published. A complete review of the literatures regarding this topic has been collected and discussed. The author also presents a 12- year old boy with triventricular hydrocephalus who had undergone ventriculoperitoneal medium pressure shunt system since birth. The patient presented to our clinic with a 2-year history of seizures. The patient was conscious and without neurological deficits on examination. Computed tomography of the brain showed bilateral high density mass with surface calcification. X ray skull and MRI confirmed the calcified subdural hematoma bilaterally. We preferred conservative treatment and the patient continued his antiepileptic treatment. At one year follow up, the patient had the same neurological state. The case highlights the importance of frequent follow up CT brain after shunt surgery.
Paediatric day-case neurosurgery in a resource challenged setting: Pattern and practice
Owojuyigbe, Afolabi Muyiwa; Komolafe, Edward O.; Adenekan, Anthony T.; Dada, Muyiwa A.; Onyia, Chiazor U.; Ogunbameru, Ibironke O.; Owagbemi, Oluwafemi F.; Talabi, Ademola O.; Faponle, Fola A.
2016-01-01
Background: It has been generally observed that children achieve better convalescence in the home environment especially if discharged same day after surgery. This is probably due to the fact that children generally tend to feel more at ease in the home environment than in the hospital setting. Only few tertiary health institutions provide routine day-case surgery for paediatric neurosurgical patients in our sub-region. Objective: To review the pattern and practice of paediatric neurosurgical day-cases at our hospital. Patients and Methods: A prospective study of all paediatric day-case neurosurgeries carried out between June 2011 and June 2014. Results: A total of 53 patients (34 males and 19 females) with age ranging from 2 days to 14 years were seen. Majority of the patients (77.4%) presented with congenital lesions, and the most common procedure carried out was spina bifida repair (32%) followed by ventriculoperitoneal shunt insertion (26.4%) for hydrocephalus. Sixty-eight percentage belonged to the American Society of Anesthesiologists physical status class 2, whereas the rest (32%) belonged to class 1. General anaesthesia was employed in 83% of cases. Parenteral paracetamol was used for intra-operative analgesia for most of the patients. Two patients had post-operative nausea and vomiting and were successfully managed. There was no case of emergency re-operation, unplanned admission, cancellation or mortality. Conclusion: Paediatric day-case neurosurgery is feasible in our environment. With careful patient selection and adequate pre-operative preparation, good outcome can be achieved. PMID:27251657
Orozco, Héctor; Tielve, Manuel; Ramos, Guillermo; Mercado, Miguel Angel
2006-01-01
There is no information in the literature about surgical outcome of the distal splenorenal shunt (Warren shunt) in those patients with anomalous flow in the left renal vein to the inferior vena cava. The purpose of this manuscript was to evaluate the incidence of thrombosis in the Warren shunt in those patients with anomalous flow in the left renal vein to the inferior vena cava. We performed a prospective, descriptive and longitudinal study in those patients who performed a surgical procedure to the treatment of hemorrhagic portal hypertension in a tertiary referral center in Mexico City during a one year period (2002-2003). Before the surgical procedure an arterial and venous angiographic study was done including celiac axis, superior mesenteric artery and splenic artery. The patients were scheduled in the outpatient office the first, third, sixth month and the year after the surgical procedure. We looked in them for gastrointestinal bleeding secondary to portal hypertension. In those patients with Warren shunt an angiographic study was done during the first month after the surgical procedure. Twenty eight patients were included, 17 of them women (60.7%). Median patient age was 48 years old. In 20 patients a Warren shunt were done and in eigth patients a devascularization operation were done. The anomalous flow of the left renal vein was identified in nine patients (28.7%). In seven of them a Warren shunt were done and in two of them a devascularization operation were done. We didn't find gastrointestinal bleeding or thrombosis of the Warren shunt in any of these patients. In those cases of patients with anomalous flow in the left renal vein a Warren shunt can be performed. In this study we didn't find thrombosis of the shunt or gastrointestinal bleeding. In this way a surgical decompression of the portal system can be done preventing bleeding episodes.
Chungsomprasong, Paweena; Bositthipichet, Densiri; Ketsara, Salisa; Titaram, Yuttapon; Chanthong, Prakul; Kanjanauthai, Supaluck
2018-01-01
Objective To compare survival of patients with newly diagnosed pulmonary arterial hypertension associated with congenital heart disease (PAH-CHD) according to various clinical classifications with classifications of anatomical-pathophysiological systemic to pulmonary shunts in a single-center cohort. Methods All prevalent cases of PAH-CHD with hemodynamic confirmation by cardiac catheterization in 1995–2015 were retrospectively reviewed. Patients who were younger than three months of age, or with single ventricle following surgery were excluded. Baseline characteristics and clinical outcomes were retrieved from the database. The survival analysis was performed at the end of 2016. Prognostic factors were identified using multivariate analysis. Results A total of 366 consecutive patients (24.5 ± 17.6 years of age, 40% male) with PAH-CHD were analyzed. Most had simple shunts (85 pre-tricuspid, 105 post-tricuspid, 102 combined shunts). Patients with pre-tricuspid shunts were significantly older at diagnosis in comparison to post-tricuspid, combined, and complex shunts. Clinical classifications identified patients as having Eisenmenger syndrome (ES, 26.8%), prevalent left to right shunt (66.7%), PAH with small defect (3%), or PAH following defect correction (3.5%). At follow-up (median = 5.9 years; 0.1–20.7 years), no statistically significant differences in survival rate were seen among the anatomical-pathophysiological shunts (p = 0.1). Conversely, the clinical classifications revealed that patients with PAH-small defect had inferior survival compared to patients with ES, PAH post-corrective surgery, or PAH with prevalent left to right shunt (p = 0.01). Significant mortality risks were functional class III, age < 10 years, PAH-small defect, elevated right atrial pressure > 15 mmHg, and baseline PVR > 8 WU•m.2 Conclusion Patients with PAH-CHD had a modest long-term survival. Different anatomical-pathophysiological shunts affect the natural presentation, while clinical classifications indicate treatment strategies and survival. Contemporary therapy improves survival in deliberately selected patients. PMID:29664959
Extended Experience with Neuroendoscopic Lavage for Posthemorrhagic Hydrocephalus in Neonates.
d'Arcangues, Charlotte; Schulz, Matthias; Bührer, Christoph; Thome, Ulrich; Krause, Matthias; Thomale, Ulrich-Wilhelm
2018-05-03
Previous studies have described neuroendoscopic lavage (NEL) as a procedure for the treatment of posthemorrhagic hydrocephalus in newborn infants. This report describes complications and results in an extended case series from 2 separate hospitals. Patient records were screened for NEL procedures performed on infants with posthemorrhagic hydrocephalus between September 2010 and May 2016 (minimum follow-up period of 12 months). Efficacy of blood removal-as assessed with cerebral ultrasound, complications, eventual shunt placement rate, and subsequent shunt revisions-were recorded. Fifty-six patients (35 male) underwent NEL at a postmenstrual median age of 31 weeks and 2 days (range, 26 weeks and 1 day to 52 weeks and 3 days) and a median weight of 1523 g (range, 734-4360 g). Median follow-up was 34 months (range, 12-80). Three patients died, and 31 patients required permanent ventriculoperitoneal shunting. There was no significant correlation between the need for ventriculoperitoneal shunting and gestational age (P = 0.05), birth weight (P = 0.07), age (P = 0.17), or weight (P = 0.59) after NEL. The median number of surgical interventions per patient was 2 (range, 1-7 interventions). Revision-free shunt survival was 63.6% at 12 and 56.2% at 24 months. NEL avoided shunt placement in 43% of newborn infants with posthemorrhagic hydrocephalus. In the shunted cohort, NEL may have also decreased the frequency of subsequent shunt revisions. The influence of NEL on neurodevelopment and safety remains to be investigated further in a multicenter setup. Copyright © 2018 Elsevier Inc. All rights reserved.
Delwel, E J; de Jong, D A; Avezaat, C J J
2005-10-01
It is difficult to predict which patients with symptoms and radiological signs of normal pressure hydrocephalus (NPH) will benefit from a shunting procedure and which patients will not. Risk of this procedure is also higher in patients with NPH than in the overall population of hydrocephalic patients. The aim of this study is to investigate which clinical characteristics, CT parameters and parameters of cerebrospinal fluid dynamics could predict improvement after shunting. Eighty-three consecutive patients with symptoms and radiological signs of NPH were included in a prospective study. Parameters of the cerebrospinal fluid dynamics were measured by calculation of computerised data obtained by a constant-flow lumbar infusion test. Sixty-six patients considered candidates for surgery were treated with a medium-pressure Spitz-Holter valve; in seventeen patients a shunting procedure was not considered indicated. Clinical and radiological follow-up was performed for at least one year postoperatively. The odds ratio, the sensitivity and specificity as well as the positive and negative predictive value of individual and combinations of measured parameters did not show a statistically significant relation to clinical improvement after shunting. We conclude that neither individual parameters nor combinations of measured parameters show any statistically significant relation to clinical improvement following shunting procedures in patients suspected of NPH. We suggest restricting the term normal pressure hydrocephalus to cases that improve after shunting and using the term normal pressure hydrocephalus syndrome for patients suspected of NPH and for patients not improving after implantation of a proven well-functioning shunt.
Maximum powers of low-loss series-shunt FET RF switches
NASA Astrophysics Data System (ADS)
Yang, Z.; Hu, X.; Yang, J.; Simin, G.; Shur, M.; Gaska, R.
2009-02-01
Low-loss high-power single pole single throw (SPST) monolithic RF switch based on AlGaN/GaN heterojunction field effect transistors (HFETs) demonstrate the insertion loss and isolation of 0.15 dB and 45.9 dB at 0.5 GHz and 0.23 dB and 34.3 dB at 2 GHz. Maximum switching powers are estimated +47 dBm or higher. Factors determining the maximum switching powers are analyzed. Design principles to obtain equally high switching powers in the ON and OFF-states are developed.
A Class of Broad-Band Dissipative Matching Networks Designed on an Insertion-Loss Basis
1952-01-25
latitude for the present : study « Note that although low~pass, performance is: usually hot desirable in microwave work, many loads encountered in...proceeä^^ch ^ "’%ur^ßör j ho^sve* "^ because there has’hot--Seen sufficient study -ofr%fei’ -’~ properties of a. öy^lprtiye U-pole. For this...admittance is placed in shunt . As long -as the resistance r^ or the conductance g-^ is less than 1, the lossy Supples are physically realizable. The
Kitzing, Yu Xuan; Gallagher, James; Waugh, Richard
2011-10-01
Congenital extrahepatic portocaval shunt is a rare condition that is described mostly in female patients. We report an unusual case of a young adult male patient with type 1 congenital extrahepatic portocaval shunt with associated development of a focal nodular hyperplasia on a background of regenerative nodules. With multi-slice CT utilisation, there is increased detection of portocaval malformation in asymptomatic patients. This congenital variant is clinically significant with associated development of hepatocellular lesions, hepatic dysfunction and/or encephalopathy. © 2011 The Authors. Journal of Medical Imaging and Radiation Oncology © 2011 The Royal Australian and New Zealand College of Radiologists.
Multiple congenital PSS in a dog: case report and literature review.
Leeman, Jessica J; Kim, Stanley E; Reese, David J; Risselada, Marije; Ellison, Gary W
2013-01-01
A 4 yr old spayed female mixed-breed dog presented with a 2 yr history of recurring increases in liver enzymes. Two congenital portosystemic shunts (PSSs) were identified using computed tomography (CT) angiography, which included a portoazygous and portorenal extrahepatic shunt. Double right renal veins were also identified. The shunts were successfully identified and attenuated with cellophane banding. Multiple congenital PSS is a rare phenomenon, but should be considered during exploratory laparotomy for PSS and in dogs with poor response to surgical attenuation of a single PSS. CT proved to be a crucial part of accurate diagnosis and surgical planning for this dog with multiple congenital PSS.
Morigaki, Ryoma; Pooh, Kyong-Hon; Nakagawa, Yoshinobu
2011-01-01
A neonate with hydrocephalus associated with Dandy-Walker malformation was successfully treated with an endoscopic placement of a transaqueductal ventricular single catheter. The modified catheter was provided with additional fenestration on its proximal side to allow simultaneous drainage from both the supra- and infratentorial compartments. This technique is well known for isolated fourth ventricles, but has not been applied to hydrocephalus associated with Dandy-Walker malformation. The cyst-ventriculoperitoneal shunt effectively drained both compartments. The patient was doing well 18 months after the surgical procedure. Endoscopic transaqueductal shunt placement can be considered, especially in patients with aqueductal patency.
Fujimura, R; Lober, R; Kamian, K; Kleiner, L
2018-01-01
Programmable ventricular shunt valves are commonly used to treat hydrocephalus. They can be adjusted to allow for varying amounts of cerebrospinal fluid (CSF) flow using an external magnetic programming device, and are susceptible to maladjustment from inadvertent exposure to magnetic fields. We describe the case of a 3-month-old girl treated for hydrocephalus with a programmable Strata TM II valve found at the incorrect setting on multiple occasions during her hospitalization despite frequent reprogramming and surveillance. We found that the Vocera badge, a common hands-free wireless communication system worn by our nursing staff, had a strong enough magnetic field to unintentionally change the shunt setting. The device is worn on the chest bringing it into close proximity to the shunt valve when care providers hold the baby, resulting in the maladjustment. Some commonly used medical devices have a magnetic field strong enough to alter programmable shunt valve settings. Here, we report that the magnetic field from the Vocera hands-free wireless communication system, combined with the worn position, results in shunt maladjustment for the Strata TM II valve. Healthcare facilities using the Vocera badges need to put protocols in place and properly educate staff members to ensure the safety of patients with Strata TM II valves.
Kojima, Seiichiro; Ito, Hiroyuki; Takashimizu, Shinji; Ichikawa, Hitoshi; Matsumoto, Tomohiro; Hasebe, Terumitsu
2016-01-01
A 64-year-old woman treated for anemia and ascites exhibited hepatic encephalopathy. Abdominal ultrasonography and computed tomography (CT) showed communication between the portal vein and the middle hepatic vein, indicating an intrahepatic portosystemic venous shunt (PSS). Since hepatic encephalopathy of the patient was resistant to medical treatment, interventional radiology was performed for the treatment of shunt obliteration. Hepatic venography showed anastomosis between the hepatic vein branches, supporting the diagnosis of idiopathic portal hypertension (IPH). To minimize the increase in portal vein pressure after shunt obliteration, partial splenic artery embolization (PSE) was first performed to reduce portal vein blood flow. Transileocolic venous obliteration (TIO) was then performed, and intrahepatic PSS was successfully obliterated using coils with n-butyl-2-cyanoacrylate (NBCA). In the present case, hepatic encephalopathy due to intrahepatic PSS in the patient with IPH was successfully treated by combination therapy using PSE and TIO. PMID:27651930
Harmonic Resonance in Power Transmission Systems due to the Addition of Shunt Capacitors
NASA Astrophysics Data System (ADS)
Patil, Hardik U.
Shunt capacitors are often added in transmission networks at suitable locations to improve the voltage profile. In this thesis, the transmission system in Arizona is considered as a test bed. Many shunt capacitors already exist in the Arizona transmission system and more are planned to be added. Addition of these shunt capacitors may create resonance conditions in response to harmonic voltages and currents. Such resonance, if it occurs, may create problematic issues in the system. It is main objective of this thesis to identify potential problematic effects that could occur after placing new shunt capacitors at selected buses in the Arizona network. Part of the objective is to create a systematic plan for avoidance of resonance issues. For this study, a method of capacitance scan is proposed. The bus admittance matrix is used as a model of the networked transmission system. The calculations on the admittance matrix were done using Matlab. The test bed is the actual transmission system in Arizona; however, for proprietary reasons, bus names are masked in the thesis copy intended for the public domain. The admittance matrix was obtained from data using the PowerWorld Simulator after equivalencing the 2016 summer peak load (planning case). The full Western Electricity Coordinating Council (WECC) system data were used. The equivalencing procedure retains only the Arizona portion of the WECC. The capacitor scan results for single capacitor placement and multiple capacitor placement cases are presented. Problematic cases are identified in the form of 'forbidden response. The harmonic voltage impact of known sources of harmonics, mainly large scale HVDC sources, is also presented. Specific key results for the study indicated include: (1) The forbidden zones obtained as per the IEEE 519 standard indicates the bus 10 to be the most problematic bus. (2) The forbidden zones also indicate that switching values for the switched shunt capacitor (if used) at bus 3 should be should be considered carefully to avoid resonance condition from existing. (3) The highest sensitivity of 0.0033 per unit for HVDC sources of harmonics was observed at bus 7 when all the HVDC sources were active at the same time.
Fu, Lijun; Wang, Qian; Wu, Jinjin; Guo, Ying; Huang, Meirong; Liu, Tingliang; Chen, Qimin; Li, Fen
2016-02-01
Congenital extrahepatic portosystemic shunt (CEPS) is a rare malformation of the mesenteric vasculature, which may lead to severe complications. In this report, we describe a case series of three children with type II CEPS (presenting as hypoxemia) and hepatopulmonary syndrome (HPS). The first patient was a 4-year-old male who did not receive any specific treatment and subsequently died of brain abscess 5 years after the diagnosis. The second patient was a 10-year-old female with a 5-year history of cyanosis and dyspnea on exertion. She had partial regression of hypoxemia and improved exercise tolerance at 8 months after a surgical shunt closure. The third patient was a 4-year-old male with a 3-year history of cyanosis and decreased exercise tolerance. He had full regression of hypoxemia at 3 months after a transcatheter shunt closure. These results indicate that CEPS may present in children with unexplained hypoxemia, which may lead to devastating clinical consequences. Closure of portosystemic shunts may result in resolution of HPS in type II CEPS and the length of period for resolution varies depending on the severity of HPS. Congenital extrahepatic portosystemic shunt (CEPS) is a rare cause of hepatopulmonary syndrome (HPS). There have been few reports in the literature about the management and outcome of HPS in children with CEPS. CEPS may present in children with unexplained hypoxemia, which may lead to devastating clinical consequences. Closure of portosystemic shunts may result in resolution of HPS in type II CEPS.
Improvised external ventricular drain in neurosurgery: A Nigerian tertiary hospital experience
Ojo, O. A.; Asha, M. A.; Bankole, O. B.; Kanu, O. O.
2015-01-01
Background: The most common type of hydrocephalus in developing countries is post infective hydrocephalus. Infected cerebrospinal fluid (CSF) however cannot be shunted for the reason that it will block the chamber of the ventriculo-peritoneal (VP) shunt due to its high protein content. In centers where standard external ventricular drain (EVD) sets are not available, improvised feeding tube can be used. Aim: The main focus of this study is to encourage the use of improvised feeding tube catheters for EVD when standard sets are not available to improve patients’ survival. Methodology: This was a prospective study. Consecutive patients with hydrocephalus that cannot be shunted immediately for high chances of shunt failure or signs of increasing intracranial pressure were recruited into the study. Other inclusion criteria were preoperative brain tumor with possibility of blocked CSF pathway and massive intraventricular hemorrhage necessitating ventricular drainage as a salvage procedure. Standard EVD set is not readily available and too expensive for most of the parents to afford. Improvised feeding tube is used to drain/divert CSF using the standard documented procedure for EVD insertion. Outcome is measured and recorded. Results: A total of 28 patients were recruited into the study over a time frame of 2 years. There were 19 (67.9%) male and 9 (32.1%) females with a ratio of about 2:1. Age ranges varied from as low as 7 days to 66 years. The median age of the study sample was 6.5 months while the mean was 173.8 months. Duration of EVD varied from 2 days to 11 days with a median of 7 while the average was 6 days. Eventual outcome following the procedure of EVD showed that 19 (67.9%) survived and were discharged either to go home or to have VP shunt afterwards while 8 (28.6%) of the patients died. Conclusions: External ventricular drain can and should be done when it is necessary. Potential mortalities could be reduced by the improvised drainage using a standard feeding tube as described. PMID:26167009
Sorensen, Sherman G; Spruance, Spotswood L; Smout, Randall; Horn, Susan
2012-06-01
Percutaneous, mechanical closure of defects of the atrial septum fails to completely resolve shunting in up to 20% of cases. Little is known about the factors associated with device failure. We measured the left atrial opening (X), right atrial opening (Z), tunnel length (Y), septum secundum, device-septum primum separation, and tunnel compressibility of the patent foramen ovale (PFO) in 301 patients with cryptogenic neurological events, PFO anatomy, and severe Valsalva shunting (Spencer Grade 5-5+). All patients then underwent percutaneous closure with the GORE®HELEX Septal Occluder device and were evaluated at 3 months for residual shunt by transcranial Doppler (TCD). Severe residual Valsalva shunt (TCD Grade 5-5+) was found at 3 months in 21 of 301 (7%) patients. X, Y, and Z were associated with failure with a high degree of statistical significance, whereas the width of the septum secundum, device-septum primum separation, and tunnel compressibility were not. An unanticipated finding was that 14 of 35 (40%) patients sized with a large balloon failed compared with 9 of 280 (3%) sized with a small balloon (P < 0.0001). In the multivariate logistic regression model, X (P = < 0.0001) and balloon size (P < 0.0001) were both strong predictors of failure. In an intracardiac echocardiography-defined PFO population, characterized by severe baseline Valsalva shunt and a high incidence of persistent (rest) shunting, association of six intracardiac measurements to closure device failure by multivariate logistic regression showed that the width of the left atrial opening was a strong predictor of residual shunting. An unanticipated finding was that use of a large sizing balloon was also strongly associated with failure. ©2012, Wiley Periodicals, Inc.
Loomba, Rohit S; Frommelt, Michele; Moe, David; Shillingford, Amanda J
2015-02-01
Agenesis of the venous duct is a rare congenital anomaly resulting in abnormal drainage of the umbilical vein into the foetal venous circulation. The clinical presentation and prognosis is variable, and may depend on the specific drainage pathways of the umbilical vein. We present two foetuses with agenesis of the venous duct, both associated with a postnatal portosystemic shunt, but with markedly different postnatal clinical courses. We also review all previously reported cases to better characterise this foetal disorder and the prognosis.
Recurrent Hyperammonemia After Abernethy Malformation Type 2 Closure: a Case Report.
Li, Hui; Ma, Zhi; Xie, Ying; Tian, Feng
The Abernethy malformation is a rare congenital malformation defined by the presence of an extrahepatic portosystemic shunt. Although most patients are asymptomatic, clinical encephalopathy is present in 15% of cases. We present a patient with type 2 Abernethy malformation, hyperammonemia, and encephalopathy. Shunt closure was performed successfully using interventional angiography; however, hyperammonemia recurred 3 months later. The diagnosis of Abernethy malformation can be made easily, but the ideal patient management strategy has not yet been established. This is the first reported patient with recurrence of hyperammonemia after interventional treatment; we discuss the therapeutic options for Abernethy malformation.
Heterotaxy syndrome with severe pulmonary hypertension in an adult.
Brandenburg, Vincent M; Krueger, Stefan; Haage, Patrick; Mertens, Peter; Riehl, Jochen
2002-05-01
Heterotaxy syndrome is a rare clinical entity in adults, characterized by situs ambiguus, congenital heart defects, and splenic malformations. We report the case of an adult with heterotaxy syndrome (including situs ambiguus, bilateral superior vena cava, hypoplastic right-sided spleen and portosystemic shunts) presenting with dyspnea due to severe pulmonary hypertension. Vasodilatory therapy was initiated, leading to marked reduction of clinical symptoms. This case exhibits 2 particular and partially novel features: primary diagnosis of heterotaxy syndrome may be delayed until adulthood, and heterotaxy syndrome may be associated with pulmonary hypertension, possibly on the basis of longstanding portosystemic shunts.
Endoscopic third ventriculostomy (ETV) for idiopathic normal pressure hydrocephalus (iNPH).
Tudor, Katarina Ivana; Tudor, Mario; McCleery, Jenny; Car, Josip
2015-07-29
Idiopathic normal pressure hydrocephalus (iNPH) is a type of communicating hydrocephalus also known as non-obstructive hydrocephalus. This type of hydrocephalus is caused by impaired cerebrospinal fluid reabsorption without any obstruction in the ventricular system and is associated with normal cerebrospinal fluid pressure. It is characterised clinically by gait disturbance, cognitive dysfunction, and urinary incontinence (known as the Hakim-Adams triad). The exact cause of iNPH is unknown. It may be managed conservatively or treated surgically by inserting a ventriculoperitoneal (VP) or ventriculoatrial (VA) shunt. However, a substantial number of patients do not respond well to surgical treatment, complication rates are high and there is often a need for further surgery. Endoscopic third ventriculostomy (ETV) is an alternative surgical intervention. It has been suggested that ETV may lead to better outcomes, including fewer complications. To determine the effectiveness of ETV for treatment of patients with iNPH compared to conservative therapy, or shunting of CSF using VP or VA shunts.To assess the perioperative and postoperative complication rates in patients with iNPH after ETV compared to conservative therapy, VP or VA shunting. We searched for eligible studies using ALOIS: a comprehensive register of dementia studies, The Cochrane Central Register of Controlled Trials (CENTRAL) and several bibliographic databases such as MEDLINE (Ovid SP), EMBASE (Ovid SP), PsycINFO (Ovid SP), CINAHL (EBSCOhost) and LILACS (BIREME).We also searched the Database of Abstracts of Reviews of Effects (DARE) to identify potentially relevant reviews. The search strategy was adapted for other databases, using the most appropriate controlled vocabulary for each. We did not apply any language or time restrictions. The searches were performed in August 2014. We included randomised controlled trials (RCTs) of ETV treatment of iNPH. Patients had to have at least two symptoms of the Hakim-Adams triad. Exclusion criteria were obstructive causes of hydrocephalus, other significant intracranial pathology and other confirmed causes of dementia. The eligible comparators were conservative treatment or shunting using VP and VA shunts. Two review authors independently screened search results, selected eligible studies, assessed risk of bias and extracted data. We contacted trial authors for additional data. Only one study met the inclusion criteria: an RCT comparing effectiveness of ETV and non-programmable VP shunts in 42 patients with iNPH. The study was conducted in Brazil between 2009 and 2012. The overall study risk of bias was high. The primary outcome in the study was the proportion of patients with improved symptoms one year after surgery, determined as a change of at least two points on the Japanese NPH scale. Due to imprecision in the results, it was not possible to determine whether there was any difference between groups in the proportion of patients who improved 3 or 12 months after surgery (3 months: odds ration (OR) 1.12, 95% confidence interval (CI) 0.26 to 4.76, n = 42; 12 months: OR 2.5, 95% CI 0.62 to 10.11, n = 38). We were unable to estimate the effect of treatment on other efficacy outcomes (cognition, balance, function, gait and mobility) because they were inadequately reported. Of the 26 patients in the VP shunting group, 5 developed subdural hematoma postoperatively, while there were no complications among the 16 patients in the ETV group (OR 0.12, 95% CI 0.01 to 2.3, n = 42), but the estimate was too imprecise to determine whether this was likely to reflect a true difference in complication rates. This was also the case for rates of further surgical intervention (OR 1.4, 95% CI 0.31 to 6.24, n = 42). There were no deaths during the trial. We judged the quality of evidence for all outcomes to be very low because of a high risk of selection, attrition and reporting bias and serious imprecision in the results. The only randomised trial of ETV for iNPH compares it to an intervention which is not a standard practice (VP shunting using a non-programmable valve). The evidence from this study is inconclusive and of very low quality. Clinicians should be aware of the limitations of the evidence. There is a need for more robust research on this topic to be able to determine the effectiveness of ETV in patients with iNPH.
Craven, Claudia; Toma, Ahmed K; Khan, Akbar A; Watkins, Laurence D
2016-09-01
Cerebrospinal fluid (CSF) leak following spinal surgery is a relatively common surgical complication. A disturbance in the underlying CSF dynamics could be the causative factor in a small group of patients with refractory CSF leaks that require multiple surgical repairs and prolonged hospital admission. A retrospective case series of patients with persistent post spinal surgery CSF leak referred to the hydrocephalus service for continuous intracranial pressure (ICP) monitoring. Patients' notes were reviewed for medical history, ICP data, radiological data, and subsequent management and outcome. Five patients (two males/three females, mean age, 35.4 years) were referred for ICP monitoring over a 12-month period. These patients had prolonged CSF leak despite multiple repair attempts 252 ± 454 days (mean ± SD). On ICP monitoring, all five patients had abnormal results, with the mean ICP 8.95 ± 4.41 mmHg. Four had abnormal pulse amplitudes, mean 6.15 mmHg ± 1.22 mmHg. All five patients underwent an intervention. Three patients underwent insertion of ventriculoperitoneal (VP) shunts. One patient had venous sinus stent insertion and one patient underwent medical management with acetazolamide. All five of the patients' CSF leak resolved post intervention. The mean time to resolution of CSF leak post intervention was 10.8 ± 12.9 days. Abnormal cerebrospinal fluid dynamics could be the underlying factor in patients with a persistent and treatment-refractory CSF leak post spinal surgery. Treatments aimed at lowering ICP may be beneficial in this group of patients. Whether abnormal pressure and dynamics represent a pre-existing abnormality or is induced by spinal surgery should be a subject of further study.
Listeria monocytogenes: a Rare Complication of Ventriculoperitoneal Shunt in Children ▿
Le Monnier, Alban; Blanot, Stéphane; Abachin, Eric; Beretti, Jean-Luc; Berche, Patrick; Kayal, Samer
2011-01-01
We report a case of ventriculoperitoneal (VP) shunt infection in a 3-year-old boy caused by the food-borne pathogen Listeria monocytogenes, subsequent to acute peritonitis. This unusual presentation of central nervous system (CNS) listeriosis underlines the ability of the bacteria to form and survive within biofilms on indwelling medical devices. Bacterial persistence may lead to treatment failure and spreading. We highlight the helpfulness of specific quantitative real-time PCR for the hly gene (PCR-hly) for the diagnosis and follow-up of such infections in detecting bacterial persistence within medical devices despite effective antibiotic treatment. Only the surgical replacement of the VP shunt will resolve the infection. PMID:21918024
NASA Astrophysics Data System (ADS)
Ye, Qiang; Hu, Jing; Cheng, Ping; Ma, Zhiqi
2015-11-01
Trade-off between shunt current loss and pumping loss is a major challenge in the design of the electrolyte piping network in a flow battery system. It is generally recognized that longer and thinner ducts are beneficial to reduce shunt current but detrimental to minimize pumping power. Base on the developed analog circuit model and the flow network model, we make case studies of multi-stack vanadium flow battery piping systems and demonstrate that both shunt current and electrolyte flow resistance can be simultaneously minimized by using longer and thicker ducts in the piping network. However, extremely long and/or thick ducts lead to a bulky system and may be prohibited by the stack structure. Accordingly, the intrinsic design trade-off is between system efficiency and compactness. Since multi-stack configurations bring both flexibility and complexity to the design process, we perform systematic comparisons among representative piping system designs to illustrate the complicated trade-offs among numerous parameters including stack number, intra-stack channel resistance and inter-stack pipe resistance. As the final design depends on various technical and economical requirements, this paper aims to provide guidelines rather than solutions for designers to locate the optimal trade-off points according to their specific cases.
[Association of biliary calculosis and portal cavernomatosis].
Crespi, C; De Giorgio, A M
1992-08-01
This paper reports the case of a woman, who underwent surgery because of cholelithiasis, with intraoperative finding of prehepatic portal hypertension from portal vein thrombosis ("portal cavernoma") with healthy liver, later confirmed by angiographic studies. This rare pathologic association carries a higher risk of major operative complications; therefore the Authors agree with the general belief that, for these cases, biliary tract surgery should be as simple and safe as possible. In the case of preoperative diagnosis of biliary disease associated with portal cavernoma, should a surgical approach on the biliary tract be required, we agree on the advisability of performing a shunting procedure before any kind of biliary surgery. In case of variceal bleeding endoscopic sclerotherapy will be the first choice; surgical procedures (shunting) should be seen as a second choice in case of rebleeding after sclerotherapy.
Ricciardi, M.
2016-01-01
The possible existence of the same pattern of porto-caval connection in dogs having a single congenital portosystemic shunt (CPSS) and in dogs having multiple acquired portosystemic shunt (MAPSS) secondary to portal hypertension (PH) was evaluated. Retrospective evaluation of all CT examinations of patients having portosystemic shunt (PSS) was performed in a 4-year time period. All anomalous porto-caval connections were assessed for anatomical pattern and compared with published veterinary literature. Records of 25 dogs were reviewed. 16 dogs had a single CPSS (CPSS group), and 9 dogs had multiple acquired PSS secondary to PH (APSS group). The splenophrenic shunt pattern was found in 3 dogs of the CPSS group as a single congenital anomaly without PH and in 2 dogs of the APSS group associated with MAPSS and ascites due to different hepatic diseases causing PH. These findings corroborate two hypotheses: 1) Splenophrenic PSS should be considered as a classical CPSS but if this is not sufficient to alleviate a PH developed after birth because of eventual hepatic or portal diseases, in this case ascites and acquired portal collaterals may develop. In this case, MAPSS and CPSS may coexist. 2) The pattern of splenophrenic PSS, classically described among CPSS, may develop as acquired portal collateral in dogs with PH and it should also be included in the category of APSS. These preliminary findings may be helpful in reconsidering the classical haemodynamics of porto-caval diseases, enrich the classification of APSS in dogs and refine the imaging evaluation of patients with PH. PMID:27882305
Case report: imaging and treatment of ophthalmic manifestations in oculodentodigital dysplasia.
Mosaed, Sameh; Jacobsen, Bradley H; Lin, Ken Young
2016-01-07
Diagnostic and surgical management of severe chronic angle- closure glaucoma secondary to ciliary body cysts can be difficult to manage in a patient with oculodentodigital dysplasia. A 6-year old girl with oculodentodigital dysplasia, with progressive chronic angle- closure glaucoma secondary to ciliary body cysts presented to our clinic. The initial examination revealed counting fingers vision in the left eye. Intraocular pressure (IOP), as assessed by tonopen, was 31 mm Hg. Ultrasound biomicroscopy revealed ciliary body cysts in the left eye, and gonioscopy confirmed chronic angle closure. A tube shunt was placed to control the elevated IOP. A year after her tube shunt placement in the left eye, ultrasound biomiscropy was performed on her right eye and showed no ciliary body cysts. Gonioscopy in the right eye revealed an open angle to the ciliary body band. Subsequent serial gonioscopy every 3 months showed gradual narrowing of the right eye angle and finally three-and-a-half years after tube placement of the left eye, her right eye IOP became uncontrolled with medications alone and a tube shunt was similarly placed in the right eye. Intraoperative ultrasound biomicroscopy performed at the time of the right eye tube shunt revealed extensive ciliary body cysts in the right eye. Her IOP in both eyes have been well controlled since the placement of tube shunts. This is one of the first reported cases of severe chronic angle- closure glaucoma secondary to ciliary body cysts in a patient with oculodentodigital dysplasia. We believe that early screening for ciliary body cysts is important in patients with oculodentodigital dysplasia.
RF performance of GaAs pHEMT switches with various upper/lower δ-doped ratio designs
NASA Astrophysics Data System (ADS)
Chiu, Hsien-Chin; Fu, Jeffrey S.; Chen, Chung-Wen
2009-02-01
AlGaAs/InGaAs pseudomorphic high-electron-mobility transistor (pHEMT) single-pole-single-throw (SPST) switches with various upper/lower δ-doped ratio designs were fabricated and investigated for the first time. Both off-state capacitance and the specific on-resistance ( Ron) of pHEMT are dominated factors and showed characteristics of sensitive to upper/lower δ-doped ratio for RF switch applications. By adopting the series-shunt architecture, upper/lower ratio of 3:1 switch achieved the lowest insertion loss compared to 4:1 design owing to the device shunt to ground (M2) of 4:1 design exhibited a worse fundamental signal isolation especially at high power level. As to the isolation under same architecture, however, due to the lowest Ron can be obtained, the 4:1 design provided better isolation performance. In addition, the M2 also dominated the second and third harmonics suppression and meanwhile, the lowest Ron of 4:1 design was found to be beneficial to the reduction of the harmonics power transmitted to the output terminal.
Díaz-Fontenla, Fernando; Castillo-Pradillo, Marta; Díaz-Gómez, Arantxa; Ibañez-Samaniego, Luis; Gancedo, Pilar; Guzmán-de-Villoria, Juan Adan; Fernández-García, Pilar; Bañares-Cañizares, Rafael; García-Martínez, Rita
2017-01-01
Hepatic encephalopathy (HE) remains a diagnosis of exclusion due to the lack of specific signs and symptoms. Refractory HE is an uncommon but serious condition that requires the search of hidden precipitating events (i.e., portosystemic shunt) and alternative diagnosis. Hypothyroidism shares clinical manifestations with HE and is usually considered within the differential diagnosis of HE. Here, we describe a patient with refractory HE who presented a large portosystemic shunt and post-ablative hypothyroidism. Her cognitive impairment, hyperammonaemia, electroencephalograph alterations, impaired neuropsychological performance, and magnetic resonance imaging and spectroscopy disturbances were highly suggestive of HE, paralleled the course of hypothyroidism and normalized after thyroid hormone replacement. There was no need for intervention over the portosystemic shunt. The case findings support that hypothyroidism may precipitate HE in cirrhotic patients by inducing hyperammonaemia and/or enhancing ammonia brain toxicity. This case led us to consider hypothyroidism not only in the differential diagnosis but also as a precipitating factor of HE. PMID:28811719
Díaz-Fontenla, Fernando; Castillo-Pradillo, Marta; Díaz-Gómez, Arantxa; Ibañez-Samaniego, Luis; Gancedo, Pilar; Guzmán-de-Villoria, Juan Adan; Fernández-García, Pilar; Bañares-Cañizares, Rafael; García-Martínez, Rita
2017-07-28
Hepatic encephalopathy (HE) remains a diagnosis of exclusion due to the lack of specific signs and symptoms. Refractory HE is an uncommon but serious condition that requires the search of hidden precipitating events ( i.e ., portosystemic shunt) and alternative diagnosis. Hypothyroidism shares clinical manifestations with HE and is usually considered within the differential diagnosis of HE. Here, we describe a patient with refractory HE who presented a large portosystemic shunt and post-ablative hypothyroidism. Her cognitive impairment, hyperammonaemia, electroencephalograph alterations, impaired neuropsychological performance, and magnetic resonance imaging and spectroscopy disturbances were highly suggestive of HE, paralleled the course of hypothyroidism and normalized after thyroid hormone replacement. There was no need for intervention over the portosystemic shunt. The case findings support that hypothyroidism may precipitate HE in cirrhotic patients by inducing hyperammonaemia and/or enhancing ammonia brain toxicity. This case led us to consider hypothyroidism not only in the differential diagnosis but also as a precipitating factor of HE.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pereira, Keith, E-mail: keithjppereira@gmail.com; Baker, Reginald, E-mail: rbaker@med.miami.edu; Salsamendi, Jason
Transjugular intrahepatic portosystemic shunts (TIPS) have evolved as an effective and durable nonsurgical option in the treatment of portal hypertension (PH). It has been shown to improve survival in decompensated cirrhosis and may also serve as a bridge to liver transplantation. In spite of the technical improvements in the procedure, problems occur with the shunt which jeopardizes effective treatment of the PH. Appropriate management is vital to ensure the longevity of the conduit. Shunt revision techniques include endovascular revision techniques and new shunt creation or, in the appropriate patients, alternative/rescue therapies. The ability of interventional radiologists to restore adequate TIPSmore » function has enormous implications for quality of life with palliation, morbidity/mortality related to variceal bleeding and survival if transplant candidates can live long enough to receive a new liver. As such, it is imperative that these treatment strategies are understood and employed when these patients are encountered. In this review, the restoration of appropriate shunt function using various techniques will be discussed as they apply to a variety of clinical scenarios, based on literature. In addition, illustrative case examples highlighting our experience at an academic tertiary medical center will be included. It is the intent to have this document serve as a concise and informative reference to be used by those who may encounter patients with suboptimal functioning TIPS.« less
Pereira, Keith; Baker, Reginald; Salsamendi, Jason; Doshi, Mehul; Kably, Issam; Bhatia, Shivank
2016-05-01
Transjugular intrahepatic portosystemic shunts (TIPS) have evolved as an effective and durable nonsurgical option in the treatment of portal hypertension (PH). It has been shown to improve survival in decompensated cirrhosis and may also serve as a bridge to liver transplantation. In spite of the technical improvements in the procedure, problems occur with the shunt which jeopardizes effective treatment of the PH. Appropriate management is vital to ensure the longevity of the conduit. Shunt revision techniques include endovascular revision techniques and new shunt creation or, in the appropriate patients, alternative/rescue therapies. The ability of interventional radiologists to restore adequate TIPS function has enormous implications for quality of life with palliation, morbidity/mortality related to variceal bleeding and survival if transplant candidates can live long enough to receive a new liver. As such, it is imperative that these treatment strategies are understood and employed when these patients are encountered. In this review, the restoration of appropriate shunt function using various techniques will be discussed as they apply to a variety of clinical scenarios, based on literature. In addition, illustrative case examples highlighting our experience at an academic tertiary medical center will be included. It is the intent to have this document serve as a concise and informative reference to be used by those who may encounter patients with suboptimal functioning TIPS.
[A case of non-traumatic tension pneumocephalus 12 years after initial ventriculo-peritoneal shunt].
Idei, Masaru; Yamane, Kanji; Okita, Shinji; Kumano, Kiyoshi; Nakae, Ryuta; Nishizawa, Shigeru
2009-10-01
The authors presented a patient with non-traumatic tension pneumocephalus 12 years after initial ventriculo-peritoneal shunt. A 60-year-old man had a past history of subarachnoid hemorrhage. At ÿtime, he underwent clipping surgery and emplacement of a ventriculoperitoneal shunt with a low pressure valve, and was discharged from hospital in a bedridden condition. After 12 years, he was transferred to our hospital because of dysarthria and right hemiparesis. On admission, he had multiple dimples of the scalp in the left frontal area where craniotomy had been carried out 12 years before. Head CT scan revealed air located mainly in bilateral subdural space and collapsed ventricles. We suspected that he had a tension pneumocephalus through a scalp-subdural fistula induced by long-term low intracranial pressure. Operation for closure of the fistula was intended. During the operation a subdural abscess was found so, artificial bone and the shunt system was removed. We were able to detect the fistula from the defect of the scalp to the subdural space and closed it by repairing a scalp defect, using dural plasty. Postoperative clinical course was uneventful and the patient was discharged. About 6 month after the operation, cranioplasty and lumbo-peritoneal shunt was performed. We must recognize that appropriate management of intracranial pressure after installation of a ventriculo-peritoneal shunt is necessary for prevention of tension pneumocephalus.
[Surgery in portal hypertension. Which patient and which operation?].
Mercado, M A; Takahashi, T; Rojas, G; Prado, E; Hernández, J; Tielve, M; Orozco, H
1993-01-01
A prospective trial of a cohort of patients (N = 94) with portal hypertension and history of bleeding was selected for surgery based on strict clinical and laboratory criteria. All of them were treated with portal blood flow preserving procedures. The following selection criteria were used: good cardiopulmonary function without pulmonary hypertension and good liver function (Child-Pugh A). All patients were operated in an elective fashion and the operations performed were: selective shunts (N = 38) (distal splenorenal and splenocaval), low diameter mesocaval shunts (N = 13) and the esophagogastric devascularization with esophageal transection (Sugiura-Futagawa) (N = 43). Patients were selected for each operation according to their anatomical conditions. Sixty-one of the patients were cirrhotics. Operative mortality was 8% and rebleeding was observed in 5% of the cases. Postoperative encephalopathy was seen in seven patients (three selective shunts, two low diameter mesocaval shunts and two devascularizations). In 13 of 62 patients postoperatively evaluated by means of angiography, portal vein thrombosis was shown (seven selective shunts, two low diameter shunts and four devascularizations). Twenty-two patients with preoperative portal vein thrombosis (and treated with a Sugiura-Futagawa operation) were excluded from postoperative angiographic evaluation. Survival (Kaplan-Meier) was 85% at 60 months. Portal blood flow preserving procedures are the treatment of choice for patients with hemorrhagic portal hypertension and good liver function. The kind of operation is selected according to the individual anatomical status of the patient.
[Ultrasound diagnosis of congenital intrahepatic portosystemic shunt].
Fu, Qiang; Tan, Shi; Cui, Li-gang; Zhang, Hua-bin; Bai, Zhi-yong; Jiang, Jie
2013-12-01
To investigate the ultrasonographic features of congenital intrahepatic portosystemic venous shunt (CIPSVS) and to assess the clinical value of ultrasonography in the diagnosis of CIPSVS. Six cases of CIPSVS diagnosed in our hospital between March 2010 and March 2012 and confirmed by enhanced computed tomography (CT) were retrospectively reviewed. Five of the six cases had follow-up data that was included in the analysis. Among the six CIPSVS cases, only one was classified as Park's type II and the rest were classified as Park's type III. Five cases involved the right lobe of the liver and only one case involved the left lobe. The lesion shapes included cystic, tubular, and irregular with clear contour and appeared to be anechoic on CT scan. The lesions ranged in size from 1.1*0.6 cm to 2.0*1.7 cm. For all cases, the color Doppler ultrasound images showed blood flowing from the portal vein to the hepatic vein, and single-phase spectrum was detected in the diversion channel. The differences observed in level of lesion size and blood flow velocity at the shunt from the time of examinations at diagnosis and subsequent follow-up did not reach statistical significance (P = 0.223 more than 0.05 and P = 0.930 more than 0.05 respectively). Although cases of CIPSVS are rare, they share some specific sonographic features that may help in diagnosis. Color Doppler ultrasound findings have high diagnostic accuracy and may represent a preferred modality for follow-up monitoring.
NASA Technical Reports Server (NTRS)
Park, Junhong; Palumbo, Daniel L.
2004-01-01
The use of shunted piezoelectric patches in reducing vibration and sound radiation of structures has several advantages over passive viscoelastic elements, e.g., lower weight with increased controllability. The performance of the piezoelectric patches depends on the shunting electronics that are designed to dissipate vibration energy through a resistive element. In past efforts most of the proposed tuning methods were based on modal properties of the structure. In these cases, the tuning applies only to one mode of interest and maximum tuning is limited to invariant points when based on den Hartog's invariant points concept. In this study, a design method based on the wave propagation approach is proposed. Optimal tuning is investigated depending on the dynamic and geometric properties that include effects from boundary conditions and position of the shunted piezoelectric patch relative to the structure. Active filters are proposed as shunting electronics to implement the tuning criteria. The developed tuning methods resulted in superior capabilities in minimizing structural vibration and noise radiation compared to other tuning methods. The tuned circuits are relatively insensitive to changes in modal properties and boundary conditions, and can applied to frequency ranges in which multiple modes have effects.
Anile, Carmelo; De Bonis, Pasquale; Albanese, Alessio; Di Chirico, Alessandro; Mangiola, Annunziato; Petrella, Gianpaolo; Santini, Pietro
2010-07-01
The ability to predict outcome after shunt placement in patients with idiopathic normal-pressure hydrocephalus (NPH) represents a challenge. To date, no single diagnostic tool or combination of tools has proved capable of reliably predicting whether the condition of a patient with suspected NPH will improve after a shunting procedure. In this paper, the authors report their experience with 120 patients with the goal of identifying CSF hydrodynamics criteria capable of selecting patients with idiopathic NPH. Specifically, they focused on the comparison between CSF-outflow resistance (R-out) and intracranial elastance (IE). Between January 1977 and December 2005, 120 patients in whom idiopathic NPH had been diagnosed (on the basis of clinical findings and imaging) underwent CSF hydrodynamics evaluation based on an intraventricular infusion test. Ninety-six patients underwent CSF shunt placement: 32 between 1977 and 1989 (Group I) on the basis of purely clinical and radiological criteria; 44 between 1990 and 2002 (Group II) on the basis of the same criteria as Group I and because they had an IE slope > 0.25; and 20 between 2003 and 2005 (Group III) on the basis of the same criteria as Group II but with an IE slope > or = 0.30. Outcomes were evaluated by means of both Stein-Langfitt and Larsson scores. Patients' conditions were considered improved when there was a stable decrease (at 6- and 12-month follow-up) of at least 1 point in the Stein-Langfitt score and 2 points in the Larsson score. Group I: while no statistically significant difference in mean R-out value between improved and unimproved cases was observed, a clear-cut IE slope value of 0.25 differentiated very sharply between unimproved and improved cases. Group II: R-out values in the 2 unimproved cases were 20 and 47 mm Hg/ml/min, respectively. The mean IE slope in the improved cases was 0.56 (range 0.30-1.4), while the IE slopes in the 2 unimproved cases were 0.26 and 0.27. Group III: the mean IE slope was 0.51 (range 0.31-0.7). The conditions of all patients improved after shunting. A significant reduction of the Evans ratio was observed in 34 (40.5%) of the 84 improved cases and in none of the unimproved cases. Our strategy based on the analysis of CSF pulse pressure parameters seems to have a great accuracy in predicting surgical outcome in clinical practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Terreni, Natalia; Vangeli, Marcello; Raimondo, Maria Luisa
Late intrahepatic hematoma is a rare complication of the transjugular intrahepatic portosystemic shunt (TIPS) procedure. We describe a patient with Budd-Chiari syndrome (BCS), who presented with a large inrahepatic hematoma 13 days after TIPS. Review of the literature reveals only two previous cases, both occurring in patients with BCS and presenting after a similar time interval. This potentially serious complication appears to be specific for TIPS in BCS.
Eroglu, Serpil; Sade, Elif; Bozbas, Huseyin; Pirat, Bahar; Yildirir, Aylin; Muderrisoglu, Haldun
2008-03-01
Left ventricular-right atrial communication, known as a Gerbode-type defect, is a rare form of ventricular septal defect. It is usually congenital, but rarely acquired. Clinical presentation is associated with the volume of the shunt. Transthoracic echocardiography is the most useful diagnostic method. We present a 63-year-old man with chronic renal failure and left ventricular-right atrial shunt.
Abernethy malformation with portal vein aneurysm.
Kumar, Atin; Kumar, Jyoti; Aggarwal, Rakesh; Srivastava, Siddharth
2008-09-01
We present the case of a 24-year-old man who was incidentally diagnosed with congenital extrahepatic portosystemic shunt with portal vein aneurysm during an investigation for non-specific abdominal pain. These are rare anomalies, and to the best of our knowledge, this is the first case reported with both anomalies associated together. Ultrasound, including color Doppler, computed tomography, and magnetic resonance imaging were performed which revealed a side-to-side shunt between the extrahepatic portal vein and the inferior vena cava, with aneurysmal fusiform dilatation of the proximal intrahepatic portal vein which ended abruptly. Etiology, clinical significance, and management strategies with regard to these abnormalities are discussed.
Matsumoto, R; Izutsu, M; Kobayashi, S; Kusano, S
1990-09-01
Intrahepatic portosystemic venous shunts (IPVS) are rare, except for the minute ones observed in cirrhotic liver. This report concerns a case with frequent episodes of consciousness loss, diagnosed as IPVS and multiple hemangioma-like lesions of the liver by US, CT and angiography. To our knowledge, this is the first report of association of IPVS and such angiographically evident hemangioma-like lesions of the liver. The etiology of IPVS is mostly considered to be congenital though, there are still many arguments about it. The relation between IPVS and the hemangioma-like lesions of the liver is discussed.
Endovascular interventions for traumatic portal venous hemorrhage complicated by portal hypertension
Sundarakumar, Dinesh Kumar; Smith, Crysela Mirta; Lopera, Jorge Enrique; Kogut, Matthew; Suri, Rajeev
2013-01-01
Life-threatening hemorrhage rarely occurs from the portal vein following blunt hepatic trauma. Traditionally, severe portal bleeding in this setting has been controlled by surgical techniques such as packing, ligation, and venorrhaphy. The presence of portal hypertension could potentially increase the amount of hemorrhage in the setting of blunt portal vein trauma making it more difficult to control. This case series describes the use of indirect carbon dioxide portography to identify portal hemorrhage. Furthermore, these cases illustrate attempted endovascular treatment utilizing a transjugular intrahepatic portosystemic shunt in one scenario and transmesocaval shunt coiling of a jejunal varix in the other. PMID:24179633
The role of liver transplantation for congenital extrahepatic portosystemic shunt.
Sakamoto, Seisuke; Shigeta, Takanobu; Fukuda, Akinari; Tanaka, Hideaki; Nakazawa, Atsuko; Nosaka, Shunsuke; Uemoto, Shinji; Kasahara, Mureo
2012-06-27
Congenital extrahepatic portosystemic shunt (CEPS) is reported more frequently because of advances in imaging techniques. Liver transplantation (LT) is a therapeutic option, although the indications for LT are still controversial. This study reviewed 34 cases of LT for CEPS, including 30 cases reported in the English medical literature and the patients treated in our department, to collect the clinical data associated with LT. The median age at diagnosis and LT was 3.7 and 6.8 years, respectively. Hepatic encephalopathy, including persistent hyperammonemia, was the most common indication of LT. Pulmonary complications, including hepatopulmonary syndrome and pulmonary hypertension, were the second most common indications of LT, and those patients underwent LT soon after the diagnosis. Although a shunt directly draining into the inferior vena cava was the most common type and managed by a simple direct anastomosis of the portal vein at LT, some cases required the modification of the portal vein reconstruction, such as interposition. Thirty patients were alive with a median follow-up period of 18 months. LT for CEPS showed an excellent outcome. The development of pulmonary complications is an early indication for LT. Precise planning of portal vein reconstruction is required before LT.
Melo, José Roberto Tude; Di Rocco, Federico; Bourgeois, Marie; Puget, Stephanie; Blauwblomme, Thomas; Sainte-Rose, Christian; Meyer, Philippe G; Zerah, Michel
2014-04-01
Subdural hematoma (SDH) is the most common finding on cranial CT in pediatric victims of abusive head trauma (AHT). The hematomas are commonly bilateral and sometimes associated with interhemispheric hyperdensity and/or convexity hemorrhages. There is no consensus regarding the best surgical treatment in such cases nor are there standardized surgical protocols. The authors report their experience and discuss the routine surgical options in the management of traumatic SDH at a Level 1 Pediatric Trauma Center. In this paper, the authors describe a cross-sectional study with consecutive revision of data described in the medical records of Hôpital Universitaire Necker-Enfants Malades between January 2008 and January 2013. During this period, all children younger than 2 years of age who were admitted with a traumatic SDH identified on CT scans were included in this study. One hundred eighty-four children who had SDH and were younger than 2 years of age were included. Their median age was 5.8 months (range 5 days-23 months), and 70% of the children were male. On admission CT scans, the SDH was bilateral in 52% of cases and homogeneously hypodense in 77%. Neurosurgical treatment was undertaken in 111 children (60%) with an admission Glasgow Coma Scale score of 12 or less, bulging fontanels, or other signs suggestive of intracranial hypertension. The first surgical option was craniotomy in 1.8% (2) of these 111 cases, decompressive craniectomy in 1.8% (2), transcutaneous subdural puncture in 15% (17), external subdural drainage in 16% (18), subdural-subgaleal shunt placement in 17% (19), and subdural-peritoneal shunt placement in 48% (53). In 82% of the children initially treated with transcutaneous subdural puncture and in 50% of those treated with external subdural drainage, increase or persistence of the SDH, CSF or skin infection, or shunt system malfunction was observed and further surgical intervention was required. There was a 26% rate of complications in patients initially treated with a subdural-peritoneal shunt. Although 52% of the patients had bilateral SDH, bilateral drainage was only required in 9.4%. The choice of treatment should be determined by the clinical and radiological characteristics of the individual case. Although effective on an emergency basis, subdural puncture and external subdural drainage are frequently insufficient to obtain complete resolution of SDH, and temporary placement of a subdural-peritoneal shunt is needed in most cases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cookson, Daniel T., E-mail: danielthomascookson@yahoo.co.uk; Zaman, Zubayr; Gordon-Smith, James
2011-02-15
Purpose: To investigate the reproducibility and technical and clinical success of the parallel technique of transjugular intrahepatic portosystemic shunt (TIPS) reduction in the management of refractory hepatic encephalopathy (HE). Materials and Methods: A 10-mm-diameter self-expanding stent graft and a 5-6-mm-diameter balloon-expandable stent were placed in parallel inside the existing TIPS in 8 patients via a dual unilateral transjugular approach. Changes in portosystemic pressure gradient and HE grade were used as primary end points. Results: TIPS reduction was technically successful in all patients. Mean {+-} standard deviation portosystemic pressure gradient before and after shunt reduction was 4.9 {+-} 3.6 mmHg (range,more » 0-12 mmHg) and 10.5 {+-} 3.9 mmHg (range, 6-18 mmHg). Duration of follow-up was 137 {+-} 117.8 days (range, 18-326 days). Clinical improvement of HE occurred in 5 patients (62.5%) with resolution of HE in 4 patients (50%). Single episodes of recurrent gastrointestinal hemorrhage occurred in 3 patients (37.5%). These were self-limiting in 2 cases and successfully managed in 1 case by correction of coagulopathy and blood transfusion. Two of these patients (25%) died, one each of renal failure and hepatorenal failure. Conclusion: The parallel technique of TIPS reduction is reproducible and has a high technical success rate. A dual unilateral transjugular approach is advantageous when performing this procedure. The parallel technique allows repeat bidirectional TIPS adjustment and may be of significant clinical benefit in the management of refractory HE.« less
Czepko, Ryszard; Cieslicki, Krzysztof
2016-05-01
Only a few reports have been published on the natural history of non-shunted patients suspected of having NPH. The aim of this study is to follow up a group of such cases. It was possible to follow up 27 patients who had not been qualified for shunting after the primary diagnosis. An assessment of Hakim's triad was performed, together with an analysis of radiological parameters and the results of lumbar infusion tests (LITs), both on admission and at the later date (on average, after 5.6 months). All parameters were analyzed with respect to periventricular lucency (PVL), atrophy, type of NPH, and the age of the patients. There were no deteriorations and six patients improved. Those who were over 50 and who had no PVL or secondary NPH tended to improve more frequently. Significant improvement of dementia was noted (p = 0.042) in all cases, and in the group of patients without PVL (p = 0.04). The size of the ventricles did not change significantly. The values of the resistance to outflow (R), elastance (E), and ICP remained stable. Analysis of our series revealed that the patients suspected of having NPH who had not been qualified for shunting did not deteriorate, while some of them even improved significantly as far as the level of dementia was concerned. As the CT and LIT parameters remained stable, there were no indications for repeating these examinations, at least within the period of nearly 6 months, which followed the primary diagnosis.
Paulsen, A Henriette; Due-Tønnessen, Bernt J; Lundar, Tryggve; Lindegaard, Karl-Fredrik
2017-02-01
To characterize shifts from the 1960s to the first decade in the 21st century as to diagnostics, case-mix, and surgical management of pediatric patients undergoing permanent CSF diversion procedures. One hundred and thirty-four patients below 15 years of age were the first time treated with CSF shunt or ETV for hydrocephalus or idiopathic intracranial hypertension (IIH) in 2009-2013. This represents our current practice. Our previously reported cohorts of shunted children 1967-1970 (n = 128) and 1985-1988 (n = 138) served as backgrounds for comparison. In the 1960s, ventriculography and head circumference measurements were the main diagnostic tools; ventriculoatrial shunt was the preferred procedure (94 %), neural tube defect (NTD) was the leading etiology (33 %), and overall 2-year survival rate was 76 % (non-tumor survival 84 %). In the 1980s, computerized tomography (CT) was the preferred diagnostic imaging tool; ventriculoperitoneal shunt (VPS) had become standard (91 %), the proportion of NTD children declined to 17 %, and the 2-year survival rate was 91 % (non-tumor survival 95 %). Hydrocephalus caused by intracranial hemorrhage had, on the other hand, increased from 7 to 19 %. In the years 2009-2013, when MRI and endoscopic third ventriculocisternostomy (ETV) were matured technologies, 73 % underwent VPS, and 23 % ETV as their initial surgical procedure. The most prevalent etiology was CNS tumor (31 %). The proportion of NTD patients was yet again halved to 8 %, while intracranial hemorrhage was also reduced to 12 %. In this last period, six children were treated with VPS for Idiopathic Intracranial Hypertension (IIH) due to unsatisfactory response to medical treatment. They all had headache, papilledema, and visual disturbances and responded favorably to treatment. The 2 years of survival was 92 % (non-tumor survival 99 %). In contrast to the previous periods, there was no early shunt related mortality (2 years). Aqueductal stenosis was a small but distinctive group in all cohorts with 5, 6 and 3 % respectively. The case-mix in pediatric patients treated with permanent CSF diversion has changed over the last half-century. With the higher proportion of children with CNS tumor patients and inclusion of the IIH children, the median age at initial surgery has shifted substantially from 3.2 to 14 months. Between the 1960s and the current cohort, 2 years of all-cause mortality fell from 24 to 8 %. Prolonged asymptomatic periods, extending 15 years, were relatively common. Nevertheless, 18 patients experienced shunt failure more than 15 years after last revision, and first-time shunt failure has been observed 29 years after initial treatment. This underscores the importance of life-long follow-up.
Cerebrospinal fluid volume measurements in hydrocephalic rats.
Basati, Sukhraaj; Desai, Bhargav; Alaraj, Ali; Charbel, Fady; Linninger, Andreas
2012-10-01
Object Experimental data about the evolution of intracranial volume and pressure in cases of hydrocephalus are limited due to the lack of available monitoring techniques. In this study, the authors validate intracranial CSF volume measurements within the lateral ventricle, while simultaneously using impedance sensors and pressure transducers in hydrocephalic animals. Methods A volume sensor was fabricated and connected to a catheter that was used as a shunt to withdraw CSF. In vitro bench-top calibration experiments were created to provide data for the animal experiments and to validate the sensors. To validate the measurement technique in a physiological system, hydrocephalus was induced in weanling rats by kaolin injection into the cisterna magna. At 28 days after induction, the sensor was implanted into the lateral ventricles. After sealing the skull using dental cement, an acute CSF drainage/infusion protocol consisting of 4 sequential phases was performed with a pump. Implant location was confirmed via radiography using intraventricular iohexol contrast administration. Results Controlled CSF shunting in vivo with hydrocephalic rats resulted in precise and accurate sensor measurements (r = 0.98). Shunting resulted in a 17.3% maximum measurement error between measured volume and actual volume as assessed by a Bland-Altman plot. A secondary outcome confirmed that both ventricular volume and intracranial pressure decreased during CSF shunting and increased during infusion. Ventricular enlargement consistent with successful hydrocephalus induction was confirmed using imaging, as well as postmortem. These results indicate that volume monitoring is feasible for clinical cases of hydrocephalus. Conclusions This work marks a departure from traditional shunting systems currently used to treat hydrocephalus. The overall clinical application is to provide alternative monitoring and treatment options for patients. Future work includes development and testing of a chronic (long-term) volume monitoring system.
Congenital intrahepatic portosystemic shunts: Imaging findings and endovascular management
Chandrasekharan, Rajsekar; Pullara, Sreekumar K; Thomas, Tixon; Kader, Nazar Puthukudiyil; Moorthy, Srikanth
2016-01-01
We present two cases of congenital intrahepatic portosystemic shunts in which the right portal vein directly communicated with the inferior venacava (IVC) in one patient and with the hepatic vein in the other. Multiple hepatic nodules consistent with focal nodular hyperplasia (FNH) were seen in the first patient. The second patient presented with recurrent history of hepatic encephalopathy. Percutaneous transhepatic embolization was performed using coils and Amplatz device following which she completely recovered. PMID:27081230
Dolezal, J
2008-02-01
To present a case report about 57-years-old woman with hypoxemia, multiple pulmonary arteriovenous (AV) malformations and lips teleangiectasis where the right-to-left shunt quantification was assessed by means of whole body scintigraphy with 9mTc-labelled human macro-aggregated albumin (MAA). A 57-years-old woman underwent X-ray and bolus enhanced lung CT for dyspnoea, hypoxemia and cyanosis. A multiple intrapulmonary arteriovenous malformations were detected. The whole-body 99mTc-MAA scintigraphy for the right-to-left shunt quantification was performed. The whole-body scintigraphy in anterior and posterior view was started after intravenous application of 185 MBq 99mTc-MAA. The double-head gamma camera Infinia (General Electric Medical Systems--GE MS) with infrared body countouring and the large field of view was used. The Gamma camera was fitted with low-energy, high resolution, parallel-hole collimator. Images were evaluated by processing system Xeleris (GE MS). The whole-body 99mTc-MAA scintigraphy revealed significant R-L shunt and uptake of radiotracer in extrapulmonary organs (brain, kidney, spleen). The right-to-left shunt ratio was 36%. The woman underwent successful percutaneous transcatheter microembolization treatment. After treatment the woman underwent the next 99mTc-MAA whole-body scintigraphy and the R-L shunt ratio decreased to 17%. The 99mTc-MAA whole-body scintigraphy assessed the right-to-left shunt ratio and improved the management of patients with multiple intrapulmonary A-V malformations. The next 99mTc-MAA scintigraphy after the percutaneous transcatheter microembolization of multiple intrapulmonary A-V malformations confirmed success of treatment.
NASA Astrophysics Data System (ADS)
Hu, Ji-Ying; Li, Zhao-Hui; Sun, Yang; Li, Qi-Hu
2016-12-01
Shear-mode piezoelectric materials have been widely used to shunt the damping of vibrations where utilizing surface or interface shear stresses. The thick-shear mode (TSM) elastic constant and the mechanical loss factor can change correspondingly when piezoelectric materials are shunted to different electrical circuits. This phenomenon makes it possible to control the performance of a shear-mode piezoelectric damping system through designing the shunt circuit. However, due to the difficulties in directly measuring the TSM elastic constant and the mechanical loss factor of piezoelectric materials, the relationships between those parameters and the shunt circuits have rarely been investigated. In this paper, a coupling TSM electro-mechanical resonant system is proposed to indirectly measure the variations of the TSM elastic constant and the mechanical loss factor of piezoelectric materials. The main idea is to transform the variations of the TSM elastic constant and the mechanical loss factor into the changes of the easily observed resonant frequency and electrical quality factor of the coupling electro-mechanical resonator. Based on this model, the formular relationships are set up theoretically with Mason equivalent circuit method and they are validated with finite element (FE) analyses. Finally, a prototype of the coupling electro-mechanical resonator is fabricated with two shear-mode PZT5A plates to investigate the TSM elastic constants and the mechanical loss factors of different circuit-shunted cases of the piezoelectric plate. Both the resonant frequency shifts and the bandwidth changes observed in experiments are in good consistence with the theoretical and FE analyses under the same shunt conditions. The proposed coupling resonator and the obtained relationships are validated with but not limited to PZT5A. Project supported by the National Defense Foundation of China (Grant No. 9149A12050414JW02180).
Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush.
Groth, Sylvia L; Greider, Kelsi L; Sponsel, William Eric
2015-01-01
To assess the utility of viscoelastic injection to induce bleb expansion and decrease intraocular pressure (IOP) in eyes with encapsulated glaucoma tube shunt blebs. Case series. Forty-three glaucomatous eyes, including 13 eyes with congenital, 13 uveitic, 5 neovascular, 5 open angle, 4 narrow angle and 3 traumatic glaucomas. Methods, interventions or testing: All patients underwent viscoelastic flush procedure. A pre-bent 27 or 30-gauge cannula was passed through a 25-gauge paracentesis, advanced over the iris across the anterior chamber, and insinuated into the tube shunt lumen. Once the cannula was firmly lodged in position, 0.45 to 0.85 ml of viscoelastic was injected to hyperinflate the bleb. Paired t-tests were performed comparing preoperative IOP and number of medications used preoperatively vs levels measured at 1, 6, 12, 18 and 24 months. Intraocular pressure was reduced from a mean preoperative level of 26.0 ± 1.2 (sem) mm Hg to 15.8 ± 1.0 at 1 month, remaining stable thereafter at each 6-month interval with 15.1 ± 1.1 mm Hg at 24 months (p < 0.0001). Medication use did not vary significantly from baseline. Pressure remained < 21 mm Hg after 2 years in 85% of eyes cannulated within 1 year of primary tube shunt implantation (n = 23), and in 62% of eyes cannulated more than 1 year after tube shunt placement (n = 20). Tube shunt expansion with bolus viscoelastic flush successfully restored encapsulated bleb function, providing a substantial (~10 mm Hg) IOP decrease into the mid-normal pressure range. This persisted in the majority of treated eyes for the entire study period. How to cite this article: Groth SL, Greider KL, Sponsel WE. Utility of Operative Glaucoma Tube Shunt Viscoelastic Bolus Flush. J Curr Glaucoma Pract 2015;9(3):73-76.
Shunting for hydrocephalus: analysis of techniques and failure patterns.
Nigim, Fares; Critchlow, Jonathan F; Schneider, Benjamin E; Chen, Clark; Kasper, Ekkehard M
2014-09-01
Hydrocephalus is characterized by ventricular dilatation because of progressive accumulation of cerebrospinal fluid. Normal pressure hydrocephalus (NPH) affects a subset of patients representing a reversible clinical triad of gait disturbance, urinary incontinence, and dementia with normal cerebrospinal fluid pressure and composition. Various shunting procedures have been used for treatment, but techniques and outcomes remain under debate. The objective of this study was to evaluate the clinical outcomes of 232 patients with and without NPH after the first-time Ventriculoperitoneal shunt placement and assessed patterns of failure between December 2004 and December 2012. Mean age was 54.7 y in non-NPH and 71.9 y in NPH patients. We used open technique in 34.3% and laparoscopic technique in 65.7% of NPH patients and 32.7% and 67.3% of the non-NPH patients, respectively. A total of 36 of 232 patients displayed shunt failure, 16.4% in NPH and 15.2% in non-NPH patients. Twenty-three of 155 patients failed after laparoscopic and 13 of 77 failed after open placement. Proximal shunt failure was more frequent in the non-NPH cohort. Distal failures accounted for 13 of 232 cases, and the difference between laparoscopic (six of 155) and open failures (seven of 77) was profound, but not between NPH- and non-NPH patients. Shunt failures are related to the placement method. Non-NPH patients showed more proximal failures. NPH patients showed fewer proximal failures. Less distal failures were observed after laparoscopic ventriculoperitoneal shunt placement without significant differences between NPH and non-NPH patients. Beyond this, laparoscopic surgery carries distinct advantages such as shorter operating room times and hospital stays, which should translate into less use of pain medications, earlier mobilization, and a lower incidence of ileus. Copyright © 2014 Elsevier Inc. All rights reserved.
Amyloid deposits and response to shunt surgery in idiopathic normal-pressure hydrocephalus.
Hiraoka, Kotaro; Narita, Wataru; Kikuchi, Hirokazu; Baba, Toru; Kanno, Shigenori; Iizuka, Osamu; Tashiro, Manabu; Furumoto, Shozo; Okamura, Nobuyuki; Furukawa, Katsutoshi; Arai, Hiroyuki; Iwata, Ren; Mori, Etsuro; Yanai, Kazuhiko
2015-09-15
In previous studies, patients with idiopathic normal-pressure hydrocephalus (iNPH) occasionally showed Alzheimer's pathology in frontal lobe cortical biopsy during cerebrospinal fluid shunt surgery or intracranial pressure monitoring. In clinical practice, the differential diagnosis of iNPH from Alzheimer's disease (AD) can be problematic, particularly because some iNPH cases exhibit AD comorbidity. In this study, we evaluated amyloid deposition in the brains of patients with iNPH before shunt surgery, and investigated the association between brain amyloid deposits and clinical improvement following the surgery. Amyloid imaging was performed in patients with iNPH or AD and also in healthy control subjects by using positron emission tomography (PET) and a radiolabeled pharmaceutical compound, (11)C-BF227. Using the cerebellar hemispheres as reference regions, the standard uptake value ratio (SUVR) of the neocortex was estimated and used as an index for amyloid deposition. In patients with iNPH, clinical symptoms were assessed before shunt surgery and 3 months after surgery. Five of the 10 patients with iNPH had neocortical SUVRs that were as high as those of AD subjects, whereas the SUVRs of the 5 patients were as low as those of healthy controls. A significant inverse correlation between neocortical SUVRs and cognitive improvements after shunt surgery was observed in iNPH. The amount of amyloid deposits ranges widely in the brains of patients with iNPH and is associated with the degree of cognitive improvement after shunt surgery. Copyright © 2015 Elsevier B.V. All rights reserved.
Pinto, Marcos Di; Conklin, Heather M.; Li, Chenghong; Merchant, Thomas E.
2012-01-01
Purpose The primary objective of this study was to examine whether children with low-grade glioma (LGG) or craniopharyngioma had impaired learning and memory after conformal radiation therapy (CRT). A secondary objective was to determine whether children who received chemotherapy before CRT, a treatment often used to delay radiation therapy in younger children with LGG, received any protective benefit with respect to learning. Methods and Materials Learning and memory in 57 children with LGG and 44 children with craniopharyngioma were assessed with the California Verbal Learning Test–Children’s Version and the Visual-Auditory Learning tests. Learning measures were administered before CRT, 6 months later, and then yearly for a total of 5 years. Results No decline in learning scores after CRT was observed when patients were grouped by diagnosis. For children with LGG, chemotherapy before CRT did not provide a protective effect on learning. Multiple regression analyses, which accounted for age and tumor volume and location, found that children treated with chemotherapy before CRT were at greater risk of decline on learning measures than those treated with CRT alone. Variables predictive of learning and memory decline included hydrocephalus, shunt insertion, younger age at time of treatment, female gender, and pre-CRT chemotherapy. Conclusions This study did not reveal any impairment or decline in learning after CRT in over-all aggregate learning scores. However, several important variables were found to have a significant effect on neurocognitive outcome. Specifically, chemotherapy before CRT was predictive of worse outcome on verbal learning in LGG patients. In addition, hydrocephalus and shunt insertion in craniopharyngioma were found to be predictive of worse neurocognitive outcome, suggesting a more aggressive natural history for those patients. PMID:22867897
Sneh-Arbib, O; Shiferstein, A; Dagan, N; Fein, S; Telem, L; Muchtar, E; Eliakim-Raz, N; Rubinovitch, B; Rubin, G; Rappaport, Z H; Paul, M
2013-12-01
Neurosurgery is characterized by a prolonged risk period for surgical site infection (SSI), mainly related to the presence of cerebrospinal fluid (CSF) drains. We aimed to examine factors associated with post-neurosurgical SSIs, focusing on post-operative factors. A prospective cohort study was conducted in a single center over a period of 18 months in Israel. Included were adult patients undergoing clean or clean-contaminated craniotomy, including craniotomies with external CSF drainage or shunts. SSIs were defined by the Centers for Disease Control and Prevention (CDC) criteria for healthcare-associated infections. All patients were followed up for 90 days and those with foreign body insertion for 1 year. We compared patients with and without SSI. A multivariable regression analysis for SSI was conducted including uncorrelated variables significantly associated with SSI. A total of 502 patients were included, with 138 (27.5%) undergoing emergent or urgent craniotomy. The overall SSI rate was 5.6% (28 patients), of which 3.2% (16 patients) were intracerebral. Non-elective surgery, external CSF drainage/monitoring devices, re-operation, and post-operative respiratory failure were independently associated with subsequent SSI. External CSF devices was the only significant risk factor for intracerebral SSIs (p < 0.001). Internal shunts or other foreign body insertions were not associated with SSIs. A phenotypically identical isolate to that causing the SSI was isolated from respiratory secretions prior to the SSI in 4/9 patients with microbiologically documented intracerebral SSIs. Patients with SSIs had longer hospital stay, poorer functional capacity on discharge, and higher 90-day mortality. We raise the possibility of post-operative infection acquisition through external CSF devices. Standard operating procedures for their maintenance are necessary.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Di Pinto, Marcos; Conklin, Heather M.; Li, Chenghong
Purpose: The primary objective of this study was to examine whether children with low-grade glioma (LGG) or craniopharyngioma had impaired learning and memory after conformal radiation therapy (CRT). A secondary objective was to determine whether children who received chemotherapy before CRT, a treatment often used to delay radiation therapy in younger children with LGG, received any protective benefit with respect to learning. Methods and Materials: Learning and memory in 57 children with LGG and 44 children with craniopharyngioma were assessed with the California Verbal Learning Test-Children's Version and the Visual-Auditory Learning tests. Learning measures were administered before CRT, 6 monthsmore » later, and then yearly for a total of 5 years. Results: No decline in learning scores after CRT was observed when patients were grouped by diagnosis. For children with LGG, chemotherapy before CRT did not provide a protective effect on learning. Multiple regression analyses, which accounted for age and tumor volume and location, found that children treated with chemotherapy before CRT were at greater risk of decline on learning measures than those treated with CRT alone. Variables predictive of learning and memory decline included hydrocephalus, shunt insertion, younger age at time of treatment, female gender, and pre-CRT chemotherapy. Conclusions: This study did not reveal any impairment or decline in learning after CRT in overall aggregate learning scores. However, several important variables were found to have a significant effect on neurocognitive outcome. Specifically, chemotherapy before CRT was predictive of worse outcome on verbal learning in LGG patients. In addition, hydrocephalus and shunt insertion in craniopharyngioma were found to be predictive of worse neurocognitive outcome, suggesting a more aggressive natural history for those patients.« less
Cerebellar toxoplasmosis in HIV/AIDS infant: case report and review of the literature.
Ibebuike, Kaunda; Mantanga, Leo; Emereole, Obioma; Ndolo, Patrice; Kajee, Afsana; Gopal, Rasik; Pather, Sugeshnee
2012-12-01
Cerebellar mass lesion is an uncommon presentation of toxoplasmosis. The authors report one rare case in an 11-month-old HIV/AIDS female infant who presented with deterioration in her developmental milestones. CT scan revealed a ring-enhancing mass lesion in the right cerebellar hemisphere with secondary obstructive hydrocephalus. A ventriculoperitoneal shunt was inserted prior to posterior fossa decompression and biopsy of the lesion. The specimens obtained were divided into two. One specimen was sent for histological diagnosis immediately after surgery while the second specimen was preserved until the release of the histology report. The initial histopathology report indicated a neoplastic process. Immunohistochemical stains were attempted but interpreted with difficulty due to severe tissue necrosis. After waiting for close to 6 weeks without a definite histological diagnosis, the preserved second specimen was sent for histological analysis as a fresh specimen, and reported a diagnosis of toxoplasmosis. This case presented diagnostic challenges to the authors whose radiological impressions of either a neoplastic lesion or a tuberculoma (based on our local neuroepidemiology) were reinforced by intraoperative findings highly suggestive of tuberculoma but which contrasted with the histological report, first as a neoplastic lesion and later toxoplasmosis. Although cerebellar toxoplasmosis is a rare complication of HIV/AIDS, this case report shows that toxoplasmosis should not be overlooked as a differential diagnosis of ring-enhancing cerebellar masses in HIV/AIDS patients irrespective of the patient's age and the absence of constitutional symptoms of toxoplasmosis.
Congenital absence of the portal vein--Case report and a review of literature.
Mistinova, Jana; Valacsai, Frantisek; Varga, Ivan
2010-10-01
Congenital absence of the portal vein (CAPV) is a rare anomaly in which the intestinal and the splenic venous drainage bypass the liver and drain into systemic veins through various venous shunts. To our knowledge, we have reviewed all 83 cases of CAPV, since first described in 1793. This equates to a rate of almost 2.5 cases per year over the last 30 years. Morgan and Superina (1994, J. Pediatr. Surg. 29:1239-1241) proposed the following classification of portosystemic anomalies; either the liver is not perfused with portal blood because of a complete shunt (Type I) or the liver is perfused with portal blood due to the presence of a partial shunt (Type II). In our case, abdominal venous blood drained into the suprarenal inferior vena cava via the left renal vein and dilated left gastric veins. After analyzing all reported cases, we recognize that more than 65% of patients are females and more than 30% of all published cases had been diagnosed by the age of 5 years. Additional anomalies are common in CAPV. In the reported cases, more then 22% of patients had congenital heart disease. Other commonly found anomalies include abnormalities of the spleen, urinary and male genital tract, brain as well as skeletal anomalies. Hepatic changes such as focal nodular hyperplasia, hepatocellular carcinoma, and hepatoblastoma are diagnosed in more then 40% of patients. This article also illustrates the radiological findings of CAPV. Radiological evaluation by ultrasound, CT, and MRI is helpful to detect coexisting abnormalities. Copyright © 2010 Wiley-Liss, Inc.
Sanakoeva, A V; Korshunov, A E; Kadyrov, Sh U; Khukhlaeva, E A; Kushel', Yu V
to develop the algorithm for defining the amount of posterior decompression of the craniovertebral junction in children with syringomyelia combined with Chiari-1 malformation. Sixty eight children with syringomyelia and Chiari-1 malformation, under age of 18 years, underwent posterior decompression of the craniovertebral junction (PDCVJ) in the period from January 2001 to June 2016. Seven (10%) patients underwent extradural decompression (EDD), 16 (24%) patients underwent extra-arachnoid duraplasty (EAD), 25 (37%) patients underwent intra-arachnoid dissection (IAD) and duraplasty, and 20 (29%) patients underwent PDCVJ and placement of a fourth ventricle-subarachnoid shunt. Clinical improvement occurred in 85% of patients, and stabilization was observed in 11% of patients. Syringomyelia regressed in 78% of cases. There were no complications associated with EDD; however, re-operation was required in 3 (43%) cases. In the case of EAD, treatment results were satisfactory in 11 (79%) patients; re-operation was required in 2 (12.5%) cases; there were no complications in the early postoperative period. The highest complication rate of 6 (30%) cases was associated with shunt placement and duraplasty. However, long-term results in this group of patients were satisfactory in 16 (94%) cases, and MRI-based positive changes were observed in 100% of cases. According to our analysis, EAD is the method of choice for PDCVJ in children with syringomyelia and Chiari-1 malformation without myelopathy symptoms. In the presence of myelopathy symptoms, intra-arachnoid dissection (with or without shunting) is an acceptable alternative. To our opinion, the use of EDD in syringomyelia is unadvisable.
Indications and results of systemic to pulmonary shunts: results from a national database.
Dorobantu, Dan Mihai; Pandey, Ragini; Sharabiani, Mansour Taghavi; Mahani, Alireza Shahidzadeh; Angelini, Gianni Davide; Martin, Robin Peter; Stoica, Serban Constantin
2016-06-01
The systemic-to-pulmonary shunt (SPS) remains an important palliative therapy in many congenital heart defects. Unlike other surgical treatments, the mortality after shunt operations has risen. We used an audit dataset to investigate potential reasons for this change and to report national results. A total of 1993 patients classified in 13 diagnoses underwent an SPS procedure between 2000 and 2013. Indication trends by era and also results before repair or next stage are reported. A dynamic hazard model with competing risks and modulated renewal was used to determine predictors of outcomes. The usage of SPS in Tetralogy of Fallot (ToF) has significantly decreased in the last decade, with cases of single ventricle (SV) and pulmonary atresia (PA) with septal communication increasing (P < 0.001 for trends). This is correlated with an increase of early mortality from 5.1% in the first half of the decade to 9.8% in the latter (P = 0.007 for trend). At 1.5 years, 13.9% of patients have died, 17.8% had a shunt reintervention and 68.3% of patients are alive and reintervention-free. Low weight, PA-intact septum, SV and central shunt type are among the factors associated with increased mortality, whereas PA-ventricular septal defect, corrected transposition, isomerism, central shunt and low weight are among those associated with increased reintervention, also having a dynamic effect on the relative risk when compared with ToF patients. Shunt reinterventions are not associated with worse outcomes when adjusted by other covariates, but they do have higher 30-day mortality if occurring earlier than 30 days from the index (P < 0.001). Patients operated in later years were found to have significantly lower survival at a distance from index. The observed historical rise in mortality for shunt operations relates to complex factors including changing practice for repair of ToF and for univentricular palliation. PA and SV patients are the groups of patients at the highest risk of death. Small size, shunt type and underlying anatomical defect are the main determinants of outcomes. Trends in indication and mortality seem to indicate that more severely ill patients benefit from shunting, but with an increase in mortality. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Pragliola, Claudio; Di Michele, Sara; Galzerano, Domenico
2017-06-07
A 56-year old male with ischemic heart disease and an unremarkable preoperative echocardiogram underwent surgical coronary revascularization. An intraoperative post pump trans-esophageal echocardiogram (TOE) performed while the patient was being ventilated at a positive end expiratory pressure (PEEP) of 8 cm H 2 O demonstrated a right to left interatrial shunt across a patent foramen ovale (PFO). Whereas oxygen saturation was normal, a reduction of the PEEP to 3 cm H 2 O led to the complete resolution of the shunt with no change in arterial blood gases. Attempts to increase the PEEP level above 3 mmHg resulted in recurrence of the interatrial shunt. The remaining of the TEE was unremarkable. Mechanical ventilation, particularly with PEEP, causes an increase in intrathoracic pressure. The resulting rise in right atrial pressure, mostly during inspiration, may unveil and pop open an unrecognized PFO, thus provoking a right to left shunt across a seemingly intact interatrial septum. This phenomenon increases the risk of paradoxical embolism and can lead to hypoxemia. The immediate management would be to adjust the ventilatory settings to a lower PEEP level. A routine search for a PFO should be performed in ventilated patients who undergo a TEE.
Early postnatal cranial vault reduction and fixation surgery for severe hydrocephalic macrocephaly.
Iyer, Rajiv R; Carey, Carolyn M; Rottgers, S Alex; Tetreault, Lisa; Shimony, Nir; Katzenstein, Jennifer; Ruas, Ernesto; Tuite, Gerald F
2018-05-01
OBJECTIVE Infants with severe hydrocephalus and extreme macrocephaly typically undergo CSF diversion early in life, which can result in significant cranial deformity due to CSF overdrainage. In this scenario, overlap of the cranial plates can precede the development of secondary synostosis and/or severe, permanent cranial deformity. As a result, extensive cranial vault remodeling is sometimes undertaken later in life, which is often challenging and has been associated with mortality and a high morbidity rate. The authors have previously described a technique for early postnatal cranial vault reduction and fixation (CVRF), in which the calvarial bones are stabilized using absorbable fixation plates in the neonatal period, in an attempt to facilitate patient positioning, simplify hydrocephalus management, and improve cosmesis. Here, the authors describe their institutional experience managing patients with extreme neonatal hydrocephalus with CSF diversion, with and without CVRF, over the past 12 years. METHODS The authors retrospectively reviewed the charts of infants with extreme hydrocephalus (head circumference > 49 cm) treated at their children's hospital with ventriculoperitoneal shunting, with or without CVRF, between 2005 and 2017. Data collected included age, sex, etiology of hydrocephalus, type of CVRF performed (anterior, posterior, or combined), follow-up duration, orbitofrontal circumference, craniometric measurements, intraoperative blood loss, operative duration, and postoperative complications. Developmental data were collected using the third edition of the Ages and Stages Questionnaire. Photographic imaging was used to demonstrate esthetic outcomes, and family questionnaires were used to evaluate satisfaction with the esthetic outcome. RESULTS Eleven patients with extreme neonatal hydrocephalus underwent CSF shunting; 5 underwent shunting alone and 6 patients underwent shunting and CVRF. For patients who underwent shunting and CVRF, the median age at CVRF was 6 days and the median interval between shunt placement and CVRF was 2.5 days. The mean extent of calvarial vault volume reduction was 44.5% (± 3.9%). The mean duration of the CVRF procedure was 108 minutes, and 5 of 6 patients required intraoperative transfusion. Of the 5 patients who underwent shunting alone, 3 developed severe cranial deformities. Of 6 patients who underwent shunting and CVRF, 1 had a poor cosmetic outcome. In the shunting-alone group, 2 patients died and 1 required extensive cranial vault correction at 10 years of age. One patient in the shunting and CVRF group also died. CONCLUSIONS CVRF in combination with CSF shunting in the neonatal period can simplify the treatment of the rare case of severe hydrocephalic macrocephaly and leads to cosmetic outcomes that are considered good by their families.
Ding, Xue-Yan; Chen, Feng; Zhao, Xian-Xian; Wu, Hong; Chen, Shao-Ping; Qin, Yong-Wen
2011-01-01
A 19-year-old male patient presented cyanosis and dyspnoea because of the presence of multiple pulmonary arteriovenous fistulas resulting in oxygen desaturation. The CTA revealed that intestinal and splenic venous blood bypasses the liver and drains into the inferior vena cava. This is the first reported case of hepatopulmonary syndrome caused by congenital extrahepatic portosystemic shunt in which intestinal and splenic venous blood bypasses the liver and drains into the inferior vena cava. PMID:22937464
Ductal paucity and Warkany syndrome in a patient with congenital extrahepatic portocaval shunt
Sood, Vikrant; Khanna, Rajeev; Alam, Seema; Rawat, Dinesh; Bhatnagar, Shorav; Rastogi, Archana
2014-01-01
An eleven-year-old clinically dysmorphic and developmentally retarded male child presenting with complaints of 5 episodes of recurrent cholestatic jaundice since 3 years of age was evaluated. Imaging revealed features consistent with congenital extrahepatic portocaval shunt (Abernethy type 1b), multiple regenerative liver nodules and intrahepatic biliary radical dilatation. The presence of ductal paucity and trisomy 8 were confirmed on liver biopsy and karyotyping. The explanation for unusual and previously unreported features in the present case has been proposed. PMID:24868329
[Foreign body in the tricuspid valve with valvular insufficiency and right-left shunt].
Delebarre, P; Augustin-Normand, C; Capronier, C; Cramer, J; Godeau, P; Letac, B; Forman, J; Maurice, P; Ourbak, P
1987-05-01
We present the case of a 50-year old man who progressively developed tricuspid valve insufficiency with opening of a patent foramen ovale responsible for right-to-left shunt with polycythaemia. The tricuspid valve insufficiency was due to a foreign body, probably of surgical origin as suggested by its radiological image and by the patient's previous history. It would have been introduced, far away from the tricuspid valve (compound fracture of the wrist), several years previously. At surgery, we found the foreign body embedded in the valve system. As a possible mechanism for the mutilation, an undiagnosed endocarditis was suspected but could not be confirmed. Three cases tricuspid endocarditis (with foreign bodies in the right ventricle) and 3 cases of asymptomatic tricuspid valve foreign bodies have been published. Fifty-five cases of foreign bodies introduced peripherally and migrated into the heart, the pericardium and the pulmonary artery are reviewed.
Adam, Fiona H; German, Alexander J; McConnell, J Fraser; Trehy, Mary R; Whitley, Nat; Collings, Alison; Watson, Penny J; Burrow, Rachel D
2012-09-15
To determine whether clinical and clinicopathologic data could assist differentiation of congenital portosystemic shunts (CPSSs) from acquired portosystemic shunts (APSSs) in young dogs. Retrospective case series. Dogs < 30 months of age with CPSSs (n = 62) or APSSs (31). Medical records from 3 referral centers identified 31 dogs with APSSs and 62 dogs with CPSSs diagnosed from July 2003 to July 2008. Signalment, clinical signs, physical examination, and clinicopathological data were recorded, and statistical analyses were performed to determine differences between groups. Univariable analysis showed APSS patients were older, heavier, and in poorer body condition, compared with CPSS patients. In CPSS patients, diarrhea was less prevalent, and neurologic signs were more prevalent. Ascites was more prevalent in APSS (Fisher exact test; OR, 50.2; 95% confidence interval [CI], 6.2 to 409.7), with no significant difference in albumin concentration between groups. The logistic regression model used to assess clinicopathological parameters showed lower Hct (OR, 1.42 × 10(-12); 95% CI, 1.42 × 10(-17) to 4.0 × 10(-6)), higher mean corpuscular volume (OR, 1.27; 95% CI, 1.08 to 1.50), and higher alanine aminotransferase concentrations (OR, 1.005; 95% CI, 1.001 to 1.009) were more likely in APSS patients. Several clinicopathologic differences between dogs with congenital and acquired shunts were identified; however, assessed alone, these would be unlikely to enable differentiation between the 2 conditions. Awareness of the rarity of ascites in CPSS cases should prompt recognition of a likely diagnosis of APSS, allowing the veterinarian to target further diagnostics and counsel the owner appropriately.
Accurate expressions for solar cell fill factors including series and shunt resistances
NASA Astrophysics Data System (ADS)
Green, Martin A.
2016-02-01
Together with open-circuit voltage and short-circuit current, fill factor is a key solar cell parameter. In their classic paper on limiting efficiency, Shockley and Queisser first investigated this factor's analytical properties showing, for ideal cells, it could be expressed implicitly in terms of the maximum power point voltage. Subsequently, fill factors usually have been calculated iteratively from such implicit expressions or from analytical approximations. In the absence of detrimental series and shunt resistances, analytical fill factor expressions have recently been published in terms of the Lambert W function available in most mathematical computing software. Using a recently identified perturbative relationship, exact expressions in terms of this function are derived in technically interesting cases when both series and shunt resistances are present but have limited impact, allowing a better understanding of their effect individually and in combination. Approximate expressions for arbitrary shunt and series resistances are then deduced, which are significantly more accurate than any previously published. A method based on the insights developed is also reported for deducing one-diode fits to experimental data.
Initial clinical experience of tube-shunt surgery in Ethiopian patients with refractory glaucoma.
T/Giorgis, Abeba
2012-04-01
In Ethiopia, it is not uncommon to encounter refractory glaucoma cases that could be managed with tube-shunt surgery. Tube-shunt implant surgery has been a standard procedure option and widely used for various forms of refractory glaucoma. To described the initial experience and outcome of Ahmed Tube shunt implant for refractory adult Ethiopian glaucoma cases. Retrospective review of consecutive adult patients with refractory glaucoma who underwent Ahmed glaucoma valve implant at the Department of ophthalmology, Menelik II Hospital, Addis Ababa between April 2009 and December 2010. intraocular pressure (IOP), visual acuity, use of supplemental medical therapy and surgical complications. Success was defined as IOP greater than 5 and less than 22 mmHg with at least 30% reduction in IOP from preoperative levels with and without supplemental glaucoma medications, no additional surgeries to lower the IOP and without visual loss of light perception from devastating postoperative complications. Thirteen eyes of 12 patients (10 men, 2 women; mean age 52.4 +/- 15. 7) who underwent glaucoma tube-shunt drainage surgery with Ahmed-tube valve were included in this analysis. The mean preoperative IOP was 31.38 +/- 8.67 mmHg with 2.23 +/- 0.44 antiglaucoma medications. Postoperatively, the mean IOP reduced to 15.52 +/- 8.80 mmHg at 1 week, 14.77 +/- 6.39 mmHg at 1 month, 16.62 +/- 4.48 mmHg at 3 months, and 17.15 +/- 3.87 mmHg at 6 months. The reduction from the preoperative mean IOP at last follow up was 45.3% with 1.08 +/- 0.44 supplemental glaucoma medications. The success rate of IOP controlling according to the definition was 76.9%. The pressure remained below 18 mmHg with and without medication in 9/13 (69.2%) eyes, while three eyes required no medication at all till the last follow-up with sustained IOP < 15 mmHg. At the last follow-up the visual acuity reduced by > or = 2 lines in two eyes while one patient's vision worsened from counting finger of one meter to hand movement. Visual improvement of one and two lines documented in two eyes. Hypotony, Tube-corneal touch, acceleration of cataract, choroidal effusion, flat anterior chamber, visual reduction and tube exposure were the types of complications encountered in 6 eyes, while 3 eyes had more than one complication. The study has shown that tube-shunt implant to be effective in lowering intraocular pressure in refractory glaucoma cases. The few cases reported are indicators of the importance of the procedure in salvaging vision of patients with refractory glaucoma and the need of large scale prospective study in the country.
[Management of arachnoid cysts of the middle cranial fossa accompanied by subdural effusions].
Abderrahmen, K; Saadaoui, K; Bouhoula, A; Boubaker, A; Jemel, H
2012-10-01
Subdural effusions are uncommon but known complications of arachnoid cysts of the middle cranial fossa. They mainly occur after minor head traumas in young patients. Here, we report eight cases of arachnoid cyst of the middle cranial fossa associated with subdural hematoma in five cases and hygroma in three cases. Major symptoms are signs of raised intracranial pressure. CT scan and MRI showed the cyst and the subdural effusion. An excellent therapeutic result was achieved with evacuation of the subdural fluid via burr holes in the five cases of subdural hematoma while in the two cases of hygroma a subduro-peritoneal shunt was necessary. In the last case, a temporal craniotomy was performed with evacuation of the hygroma and fenestration of the cyst. We suggest treating only the complicating event in the case of a subdural hematoma via burr holes evacuation. Whereas, in the case of hygroma we think that craniotomy with fenestration of the cyst or the use of a subdural shunt are more often needed. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Cerebrospinal fluid dynamics study in communicating hydrocephalus.
Ramesh, Vengalathur Ganesan; Narasimhan, Vidhya; Balasubramanian, Chandramouli
2017-01-01
Communicating hydrocephalus often poses a challenge in diagnosis and management decisions. The objective of this study is to measure the opening pressure (P o ), pressure volume index (PVI), and cerebrospinal fluid outflow resistance (R out ), in patients with communicating hydrocephalus using bolus lumbar injection method and to evaluate its diagnostic and prognostic value. The study was conducted in 50 patients with communicating hydrocephalus, including normal pressure hydrocephalus (NPH) (19), post-meningitic hydrocephalus (23) and post-traumatic hydrocephalus (8). An improvised bolus lumbar injection method [the Madras Institute of Neurology (MIN) method] was used. In the NPH Group, the CSF dynamics studies correlated well with the clinico-radiological classification. The prediction of shunt responsiveness by CSF dynamics studies correlated with good outcome in 87.5%. In the post-meningitic hydrocephalus group, the value of CSF dynamics studies in predicting patients needing shunt was 89.5%. The CSF dynamics studies detected patients who needed shunt earlier than clinical or radiological indications. In the post-traumatic hydrocephalus group, 62.5% of patients improved with the treatment based on CSF dynamics studies. The improvised bolus lumbar injection method (MIN method) is a very simple test with fairly reliable and reproducible results. Study of CSF dynamics is a valuable tool in communicating hydrocephalus for confirmation of diagnosis and predicting shunt responsiveness. This is the first time that the value of CSF dynamics has been studied in patients with post-meningitic hydrocephalus. It was also useful for early selection of cases for shunting and for identifying patients with atrophic ventriculomegaly, thereby avoiding unnecessary shunt.
Cerebrospinal fluid dynamics study in communicating hydrocephalus
Ramesh, Vengalathur Ganesan; Narasimhan, Vidhya; Balasubramanian, Chandramouli
2017-01-01
Context: Communicating hydrocephalus often poses a challenge in diagnosis and management decisions. Aims: The objective of this study is to measure the opening pressure (Po), pressure volume index (PVI), and cerebrospinal fluid outflow resistance (Rout), in patients with communicating hydrocephalus using bolus lumbar injection method and to evaluate its diagnostic and prognostic value. Materials and Methods: The study was conducted in 50 patients with communicating hydrocephalus, including normal pressure hydrocephalus (NPH) (19), post-meningitic hydrocephalus (23) and post-traumatic hydrocephalus (8). An improvised bolus lumbar injection method [the Madras Institute of Neurology (MIN) method] was used. Results: In the NPH Group, the CSF dynamics studies correlated well with the clinico-radiological classification. The prediction of shunt responsiveness by CSF dynamics studies correlated with good outcome in 87.5%. In the post-meningitic hydrocephalus group, the value of CSF dynamics studies in predicting patients needing shunt was 89.5%. The CSF dynamics studies detected patients who needed shunt earlier than clinical or radiological indications. In the post-traumatic hydrocephalus group, 62.5% of patients improved with the treatment based on CSF dynamics studies. Conclusions: The improvised bolus lumbar injection method (MIN method) is a very simple test with fairly reliable and reproducible results. Study of CSF dynamics is a valuable tool in communicating hydrocephalus for confirmation of diagnosis and predicting shunt responsiveness. This is the first time that the value of CSF dynamics has been studied in patients with post-meningitic hydrocephalus. It was also useful for early selection of cases for shunting and for identifying patients with atrophic ventriculomegaly, thereby avoiding unnecessary shunt. PMID:28484522
Satyarthee, Guru Dutta; Dawar, Pankaj; Sharma, Bhawani Shanker
2013-11-01
Subdural effusion in an infant is a rare clinical scenario which may be secondary to a variety of etiologies. Massive subdural effusion is an extremely rare complication of head injury. Authors report a rare case of progressive massive subdural effusion which, despite bilateral bur-hole placement and drainage, failed and presented with visual deterioration and massive bulge of the scalp at bur-hole sites, producing a rabbit ear appearance in a 10-month-old infant. Ultimately, cystoperitoneal shunt was carried out in a desperate attempt to prevent impending rupture of scalp sutures at sites of previous bur-hole placement. This was followed by not only complete resolution of hygroma but also visual recovery. The patient is doing well at 6 months following shunt, regaining normal vision and appropriate developmental milestones. A MRI scan of the brain was carried out at last follow-up, which revealed mild ventriculomegaly with the rest of the brain being unremarkable, and subduro-peritoneal shunt in situ. Such a case has not been reported in the literature till date. Subdural effusion usually runs a self-limiting course. Though neurosurgical intervention is occasionally needed, different methods of surgical procedure for management include bur hole alone, bur holes with subdural drain placement, twist drill craniotomy with drain, and even craniotomy. Various methods of management are discussed along with a review of pertinent literature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bazeries, Paul, E-mail: paul.bazeries@chu-angers.fr; Paisant-Thouveny, Francine; Yahya, Sultan
ObjectiveTo report our clinical practice regarding a case series of retained products of conception (RPOC) with marked vascularity (MV) managed with selective uterine artery embolization (UAE) as first-line treatment.MethodsThis was a monocentric, retrospective study of 31 consecutive cases of RPOC with MV diagnosed by Doppler ultrasound in the context of postpartum/postabortal bleeding. The primary outcome was the absence of rebleeding following embolization.ResultsRPOC with MV occurred after abortion in 27 out of 31 patients (87%). The time elapsed between delivery/abortion and UAE ranged from 1 to 210 days (mean 55.7 ± 45 days). Primary clinical success was achieved in 23 women (74.2%) following a singlemore » embolization. In total, 27 out of 31 women (87%) had been exclusively managed by UAE with conservative success. Although procedural success was achieved in this number, six women had a further procedure to evacuate RPOC despite procedural success. Large uterine arteriovenous (AV) shunts associated with RPOC were observed in five cases (16.1%), among which two were successfully treated after a single UAE and one after two UAEs, while hysterectomy was performed in the last two cases despite two and three UAE procedures respectively. RPOC was histologically proven in ten cases (32.2%) including four out of five cases of uterine AV shunt.ConclusionRPOC with MV can present with large uterine AV shunt, particularly in case of late management. Uterine artery embolization is an effective and safe first-line treatment, and should be evaluated for this indication in larger prospective trials.« less
Agrawal, Abhinav; Palkar, Atul V; Sahni, Sonu; Vatsia, Sheel K; Shah, Rakesh D; Talwar, Arunabh
2016-01-01
Partial anomalous pulmonary venous connection (PAPVC) is a rare congenital anomaly that leads to an anatomical left-to-right shunt. Termination of the intrahepatic inferior vena cava (IVC) with its azygos continuation associated with the hepatic venous connection to the left atrium (LA) is also a rare congenital anomaly that results in an anatomical right-to-left shunt. A 65-year-old male presented with severe dyspnea on exertion and pedal edema. He was further diagnosed at our clinic and was found to have both the aforementioned congenital abnormalities, creating a bidirectional shunt. On further investigation, he was found to have nocturnal hypoxemia on overnight oximetry. The patient was successfully treated via surgical corrections of the congenital anomalies leading to symptomatic improvement as well as the resolution of nocturnal hypoxemia.
Management and classification of type II congenital portosystemic shunts.
Lautz, Timothy B; Tantemsapya, Niramol; Rowell, Erin; Superina, Riccardo A
2011-02-01
Congenital portosystemic shunts (PSS) with preserved intrahepatic portal flow (type II) present with a range of clinical signs. The indications for and benefits of repair of PSS remain incompletely understood. A more comprehensive classification may also benefit comparative analyses from different institutions. All children treated at our institution for type II congenital PSS from 1999 through 2009 were reviewed for presentation, treatment, and outcome. Ten children (7 boys) with type II PSS were identified at a median age of 5.5 years. Hyperammonemia with varying degrees of neurocognitive dysfunction occurred in 80%. The shunt arose from a branch of the portal vein (type IIa; n = 2), from the main portal vein (type IIb; n = 7), or from a splenic or mesenteric vein (type IIc; n = 1). Management included operative ligation (n = 6), endovascular occlusion (n = 3), or a combined approach (n = 1). Shunt occlusion was successful in all cases. Serum ammonia decreased from 130 ± 115 μmol/L preoperatively to 31 ± 15 μmol/L postoperatively (P = .03). Additional benefits included resolution of neurocognitive dysfunction (n = 3), liver nodules (n = 1), and vaginal bleeding (n = 1). Correction of type II PSS relieves a wide array of symptoms. Surgery is indicated for patients with clinically significant shunting. A refined classification system will permit future comparison of patients with similar physiology. Copyright © 2011 Elsevier Inc. All rights reserved.
Jang, Sung Ho; Kwon, Younghyeon
2018-03-01
A 45-year-old right-handed female patient suffered head trauma after being hit by a truck that ran into a house. The patient lost consciousness for 1 hour and experienced posttraumatic amnesia for 1 month after the accident. She underwent conservative management for a subdural hematoma in the left frontotemporal lobes and intracerebral hematoma in the left frontal lobe. The patient's Glasgow Coma Scale score was 11. She underwent a VP shunt operation, approached through the right posterior parietal area of the brain, at 4 months after onset. Approximately, 6 months after onset, she was admitted to the rehabilitation department of a university hospital. She presented with moderate weakness of the left leg: Medical Research Council scores: hip flexor; 3, knee extensor; 3+, ankle dorsiflexor; 3-. Brain magnetic resonance imaging revealed a leukomalactic lesion in the right posterior corona radiata along the shunt. On 6-month (2 months after the shunt operation) diffusion tensor tractography, the left CST showed partial injury in the posterior portion compared with the right CST. On 6-month transcranial magnetic stimulation study, the motor-evoked potential obtained at the left tibialis anterior muscle revealed lower amplitude than that on the right side. Injury of leg somatotopy of a CST was demonstrated in a patient with leg weakness following a VP shunt operation.
Wang, Ruo-Yi; Wang, Jun-Feng; Liu, Qian; Ma, Nan; Chen, Wei-Xiu; Li, Jin-Liang
2017-09-01
To evaluate the effects of combined Rex-bypass shunt and pericardial devascularization on prehepatic portal hypertension secondary to cavernomatous transformation of portal vein (CTPV). Forty-two patients aged from 3 years to 49 years (divided into 3 groups), 26 cases male and 16 female, with prehepatic vascular hepertention were treated with Rex-bypass shunt combined with pericardial devascularization. In each patient, preoperative assessment included ultrasound and computed tomographic angiography of the portal vein and blood analysis. The procedure was Rex-bypass shunt (with or without graft), and patients with moderate or severe gastroesophageal varices required additional paraesophagogastric devascularization. Splenectomy or subtotal splenectomy was performed if combined hypersplenism co-existed. All data were analyzed retrospectively. No intraoperative death occurred, blood routine analysis improved (P < 0.05), the blood flow velocity (P < 0.05) and diameter (P < 0.05) of the left portal vein (LPV) significantly increased, the esophageal and gastric varices significantly relieved in 34 patients (P < 0.05), and better effects of earlier operations were demonstrated than the delayed ones (P < 0.05). During the period of follow-up from 6 to 64 months, the overall patency rate was 85.7% and the younger the age the better of the effect. Rex-bypass shunt combined with pericardial devascularization is a safe and effective procedure for prehepatic portal hypertension caused by CTPV.
Embolization of congenital intrahepatic porto-systemic shunt by n-butyl cyanoacrylate.
Gupta, Vivek; Kalra, Naveen; Vyas, Sameer; Sodhi, K S; Thapa, B R; Khandelwal, N
2009-10-01
Congenital intrahepatic portosystemic venous shunt (IHPSVS) is rare vascular anomaly. We present one case of a 14-month male child who presented with global developmental delay. Child had high ammonia levels with low glutamine and high bile salts on the previous investigations and had history of neonatal seizures since day 13 of life. On admission, serum ammonia levels were elevated to 112micromol/L. Other laboratory investigations including liver and renal function test, and electrolytes were normal. He was, diagnosed to have IHPSVS on the basis of Doppler and CT, and treated by embolization with n-butyl cyanoacrylate (glue). A brief review of diagnostic modalities and endovascular management for the IHPSVS is presented including the present case.
Management Strategies for Hydrocephalus in Alobar Holoprosencephaly: A Case Report and Discussion.
Sarica, Can; Yucetas, Cem; Ozen, Ali; Ucler, Necati; Konca, Capan; Akar, Selahattin
2018-06-14
Holoprosencephaly is a rare congenital malformation resulting from an impaired midline division of the prosencephalon into distinct cerebral hemispheres. Hydrocephalus is a frequent problem among the few survivors with alobar holoprosencephaly (aHPE), its most severe form. The literature about neurosurgical management of hydrocephalus in this condition is limited and dispersed, and there are still some points that need to be resolved. We report the case of a newborn with aHPE, hydrocephalus, and central diabetes insipidus. We delineate the complexity of the management of these patients and emphasize the benefits of using an initial programmable shunt valve. Further discussion about management strategies includes reviewing previous reports and the benefits of shunting for hypothalamic osmoreceptor function. © 2018 S. Karger AG, Basel.
Pomeraniec, I Jonathan; Bond, Aaron E; Lopes, M Beatriz; Jane, John A
2016-02-01
Normal pressure hydrocephalus (NPH) remains most often a clinical diagnosis and has been widely considered responsive to the placement of a cerebrospinal fluid (CSF) shunt. The high incidence of patients with Alzheimer's disease (AD) with NPH symptoms leads to poorer outcomes than would be expected in patients with NPH alone. This article reviews a series of patients operated on for presumed NPH in whom preoperative high-volume lumbar puncture (HVLP) and intraoperative cortical brain biopsies were performed. The data derived from these procedures were then used to understand the incidence of AD in patients presenting with NPH symptoms and to analyze the efficacy of HVLP in patients with NPH and patients with concurrent AD (NPH+AD). A review of the outcomes of shunt surgery is provided. The cases of all patients who underwent placement of a CSF shunt for NPH from 1998 to 2013 at the University of Virginia by the senior author were retrospectively reviewed. Patients who underwent HVLP and patients who underwent cortical brain biopsies were stratified based on the biopsy results into an NPH-only group and an NPH+AD group. The HVLP results and outcomes were then compared in these 2 groups. From 1998 to 2013, 142 patients underwent shunt operations because of a preoperative clinical diagnosis of NPH. Of the patients with a shunt who had a diagnosis of NPH, 105 (74%) received HVLPs. Of 142 shunt-treated patients with NPH, 27 (19%) were determined to have concomitant Alzheimer's pathology based on histopathological findings at the time of shunting. Patients who underwent repeat biopsies had an initial positive outcome. After they clinically deteriorated, they underwent repeat biopsies during shunt interrogation, and 13% of the repeat biopsies demonstrated Alzheimer's pathology. Improvements in gait and cognition did not reach significance between the NPH and NPH+AD groups. In total, 105 patients underwent HVLP before shunt placement. In the NPH cohort, 44.6% of patients experienced improvement in symptoms with HVLP and went on to experience resolution or improvement. In the NPH+AD cohort, this proportion was lower (18.2%), and the majority of patients who experienced symptomatic relief with HVLP actually went on to experience either no change or worsening of symptoms (p = 0.0136). A high prevalence of AD histopathological findings (19%) occurred in patients treated with shunts for NPH based on cortical brain biopsies performed during placement of CSF shunts. HVLP results alone were not predictive of clinical outcome. However, cortical brain biopsy results and the presence of Alzheimer's pathology had a strong correlation with success after CSF shunting. Thirteen percent of patients who initially had a normal cortical brain biopsy result had evidence of AD pathology on repeat biopsy, demonstrating the progressive nature of the disease.
Weber, S U; Hammerstingl, C; Mellert, F; Baumgarten, G; Putensen, C; Knuefermann, P
2012-01-01
The case of a young male motor vehicle driver is reported who suffered multiple trauma in a car accident with pulmonary and cardiac contusions. In the course of severe pneumonia and traumatic tricuspid valve insufficiency a right-to-left shunt with refractory hypoxemia developed across a pre-existing atrial septal defect (ASD). The patient could be successfully treated by the combination of extracorporeal membrane oxygenation for bridging, interventional ASD occlusion and in the long-term by operative reconstruction of the tricuspid valve.
Electro-thermal FEM simulations of the 13 kA LHC joints
NASA Astrophysics Data System (ADS)
Molnar, D.; Verweij, A. P.; Bielert, E. R.
2013-01-01
The interconnections between the superconducting main dipole and main quadrupole magnets are made of soldered joints of two superconducting Nb-Ti cables embedded in a copper busbar stabilizer. The primary cause of the September 2008 incident in the LHC was a defect in an interconnection between two dipole magnets. Analyses of the incident show that possibly more defects might be present in the 13 kA circuits, which can lead to unprotected resistive transitions. To avoid the reoccurrence of such an event, thorough experimental and numerical investigations have taken place to determine the safe operating conditions of the LHC. However to show measured curves is beyond the scope of this article. Furthermore, improvements in the design have been proposed in the form of additional parallel copper pieces, or shunts, which bridge the possible voids in the soldering and offer a bypass for the current in case of a quench. The purpose of this work is to support the design choices and to indicate the sensitivity to some of the free parameters in the design. Electro-thermal Finite Element Method (FEM) simulations are performed, making use of COMSOL Multiphysics. The use of FEM allows for a profound three-dimensional analysis and some interesting features of the shunted busbar can only be revealed this way. Especially current redistribution in the shunted area of the interconnect gives important insights in the problem. The results obtained using the model are very sensitive to the exact geometrical properties as well as to the material properties, which drive the Joule heating inside the interconnection. Differences as compared to a one-dimensional model, QP3, are presented. QP3 is also used for simulations of non-shunted busbar joints as well as shunted busbars. Furthermore, margins are given for the soldering process and the quality control of the shunted interconnections, since the contact area between the stabilizer pieces and the shunt is an important quality aspect during the manufacturing of a safe interconnection.
Bakare, Adewale A; Weyhenmeyer, Jonathan; Lee, Albert
2018-02-01
Perhaps the most disabling condition seen in patients with spinal cord injury (SCI) is spasticity. Spasticity is characterized as hyperreflexia and hypertonicity as a result of damage to the supraspinal tracts in the aftermath of SCI. Intrathecal baclofen (ITB) is the mainstay therapy for spasticity unresponsive to oral baclofen. One of the problems associated with post-SCI spasticity unresponsive to ITB is the development of scar tissue that prevents the diffusion of baclofen in the desired spinal cord area. This case offers a unique strategy to deal with multilevel scar tissue. This 46-year-old paraplegic male with a T8 SCI whose spasticity had been well managed with ITB therapy for many years recently suffered intractable spasticity necessitating multiple reoperations for a nonfunctioning ITB catheter secondary to extensive scar tissue and intrathecal adhesions. Placement of a subarachnoid-to-subarachnoid shunt eliminated the problem of extensive scar tissue preventing adequate baclofen therapy. After undergoing multilevel thoracic and lumbar laminectomies with subarachnoid-to-subarachnoid spinal shunt, the patient's spasticity was finally brought under control with adequate daily baclofen infusion. This case demonstrates a creative way to address ITB catheter failure before considering other measures, such as neuroablative procedures (e.g., rhizotomy, myelotomy). This case reinforces the recommendation that ablative procedures, which have far greater complications, should be reserved for patients who have failed medical or other nonablative therapies. Copyright © 2017 Elsevier Inc. All rights reserved.
Normal pressure hydrocephalus: Diagnostic and predictive evaluationon
Damasceno, Benito Pereira
2009-01-01
In typical cases, normal pressure hydrocephalus (NPH) manifests itself with the triad of gait disturbance, which begins first, followed by mental deterioration and urinary incontinence associated with ventriculomegaly (on CT or MRI) and normal cerebrospinal fluid (CSF) pressure. These cases present minor diagnostic difficulties and are the most likely to improve after shunting. Problems arise when NPH shows atypical or incomplete clinical manifestations (25–50% of cases) or is mimicked by other diseases. In this scenario, other complementary tests have to be used, preferentially those that can best predict surgical outcome. Radionuclide cisternography, intracranial pressure monitoring (ICP) and lumbar infusion tests can show CSF dynamics malfunction, but none are able to confirm whether the patient will benefit from surgery. The CSF tap test (CSF-TT) is the only procedure that can temporarily simulate the effect of definitive shunt. Since the one tap CSF-TT has low sensitivity, it cannot be used to exclude patients from surgery. In such cases, we have to resort to a repeated CSF-TT (RTT) or continuous lumbar external drainage (LED). The most reliable prediction would be achieved if RTT or LED proved positive, in addition to the occurrence of B-waves during more than 50% of ICP recording time. This review was based on a PubMed literature search from 1966 to date. It focuses on clinical presentation, neuroimaging, complementary prognostic tests, and differential diagnosis of NPH, particularly on the problem of selecting appropriate candidates for shunt. PMID:29213603
Cerebrospinal Fluid Shunting Complications in Children
Hanak, Brian W.; Bonow, Robert H.; Harris, Carolyn A.; Browd, Samuel R.
2018-01-01
Although cerebrospinal fluid (CSF) shunt placement is the most common procedure performed by pediatric neurosurgeons, shunts remain among the most failure-prone life-sustaining medical devices implanted in modern medical practice. This article provides an overview of the mechanisms of CSF shunt failure for the 3 most commonly employed definitive CSF shunts in the practice of pediatric neurosurgery: ventriculoperitoneal, ventriculopleural, and ventriculoatrial. The text has been partitioned into the broad modes of shunt failure: obstruction, infection, mechanical shunt failure, overdrainage, and distal catheter site-specific failures. Clinical management strategies for the various modes of shunt failure are discussed as are research efforts directed towards reducing shunt complication rates. As it is unlikely that CSF shunting will become an obsolete procedure in the foreseeable future, it is incumbent on the pediatric neurosurgery community to maintain focused efforts to improve our understanding of and management strategies for shunt failure and shunt-related morbidity. PMID:28249297
Ho, Chi-Lin; Jan, Sheng-Ling; Lin, Ming-Chih; Fu, Yun-Ching
2008-12-01
To assess the incidence and natural history of full-term neonates with interatrial shunt (IAS). A follow-up study of 1389 neonates who received screening echocardiography between 2003 and 2006. Babies with IAS at 2 to 4 days of life underwent follow-up echocardiography at 2 to 4 months, 6 to 9 months and 12 to 15 months of age until closure of IAS. The ratio of IAS was 68.3% initially. No significant demographic differences were identified between infants with and without initial IAS. Among 949 neonates with initial IAS, 84.5% infants had a left-to-right interatrial shunt, 13.5% had bidirectional shunt and 2% had predominantly right-to-left shunt. The persistence rate of IAS at 12 to 15 months of age was 3.8% (44/1166). The initial size of IAS ranged from 1.2 to 7.7mm (4.3+/-1.1 mm) detected by color Doppler flow mapping and cases were divided into three groups: small (< or =5 mm), medium (5 to 8 mm) and large group (> or =8 mm). There were 74.6% infants in the small group and 25.4% in the medium group initially. The neonates in the initial small group would always see their IAS close or else they would remain in the small group. Those in the final medium and large size groups always came from the initial medium group. The late closure rate of IAS was 93.9% of infants with initial IAS. The closure curves of initial small and medium sized groups were significantly different, and their late closure rates were 95.1% and 90.4%, respectively. IAS was very common during early neonatal stage, but most cases would close after 1 year. The late closure rate of initial IAS was different if using a cutpoint of 5 mm.
Ishikawa, Tsuyoshi; Aibe, Yuki; Matsuda, Takashi; Iwamoto, Takuya; Takami, Taro; Sakaida, Isao
2017-09-01
The purpose of this study was to evaluate predictors of reduction in ammonia levels by occlusion of portosystemic shunts (PSS) in patients with cirrhosis. Forty-eight patients with cirrhosis (21 women, 27 men; mean age, 67.8 years) with PSS underwent balloon-occluded retrograde transvenous obliteration (BRTO) at one institution between February 2008 and June 2014. The causes of cirrhosis were hepatitis B in one case, hepatitis C in 20 cases, alcohol in 15 cases, nonalcoholic steatohepatitis in eight cases, and other conditions in four cases. The Child-Pugh classes were A in 24 cases, B in 23 cases, and C in one case. The indication for BRTO was gastric varices in 40 cases and hepatic encephalopathy in eight cases. Testing was conducted before and 1 month after the procedure. Statistical analyses were performed to identify predictors of a clinically significant decline in ammonia levels after BRTO. Occlusion of PSS resulted in a clinically significant decrease in ammonia levels accompanied by increased portal venous flow and improved Child-Pugh score. Univariate analyses showed that a reduction in ammonia levels due to BRTO was significantly related to lower plasma glucose levels, higher RBC counts, and higher hemoglobin concentration before the treatment. Furthermore, multivariate logistic regression identified preoperative plasma glucose level as the strongest independent predictor of a significant ammonia reduction in response to BRTO. In addition, although BRTO resulted in significantly declined ammonia levels in patients with normal glucose tolerance before the procedure, ammonia levels were not significantly decreased after shunt occlusion in patients with diabetes mellitus or impaired glucose tolerance before BRTO, according to 75-g oral glucose tolerance test results. Preoperative plasma glucose level is a useful predictor of clinically significant ammonia reduction resulting from occlusion of PSS in patients with cirrhosis. Even if PSS are present, control of blood ammonia levels by BRTO alone may be difficult in patients with glucose intolerance.
Macroscopic hematuria caused by congenital portosystemic shunt and concomitant nutcracker syndrome.
Lee, Sang Hyub; Lee, Dong-Gi
2015-06-01
Nutcracker syndrome (NCS) is an uncommon vascular abnormality that causes a variety of symptoms that range from asymptomatic microscopic hematuria to severe pelvic congestion. Congenital portosystemic shunt (CPSS) is an extremely rare anomaly that causes serious complications. Many cases of NCS and CPSS that have presented separately have been reported, but no cases of concomitant NCS and CPSS have been reported. We present a case of intermittent macroscopic hematuria in a patient with both NCS and CPSS. We diagnosed NCS on pressure gradient between the left renal vein (LRV) and the inferior vena cava. The presence of CPSS, which emerged from the LRV and connected to the extrahepatic portal vein, was confirmed on computed tomography. The interaction between NCS and CPSS resulted in mild intermittent macroscopic hematuria only, rather than the more common symptoms that occur when NCS or CPSS present separately. © 2015 Japan Pediatric Society.
HAO, YABIN; HONG, XU; ZHAO, XINYAN
2015-01-01
Abernethy malformation is a rare congenital malformation defined by an extrahepatic portosystemic shunt. The majority of affected patients are young (<18 years of age) and experience various symptoms, including vomiting, jaundice, dyspnea and coma. The current study presents a case of Abernethy malformation in an asymptomatic adult male patient. The patient exhibited congenital absence of the portal vein, congenital heart disease (postoperative ventricular septal defect status), and multiple liver lesions, confirmed to be focal nodular hyperplasia by biopsy. Ultrasonography and magnetic resonance imaging findings revealing the liver lesions, type II congenital absence of the portal vein and the portosystemic shunt are presented. In addition, the common clinical presentations, associated anomalies, diagnostic workup and treatment options of this disorder are investigated by reviewing 101 previously reported cases. PMID:25624897
Chylous Ascites: Evaluation and Management
Al-Busafi, Said A.; Ghali, Peter; Deschênes, Marc; Wong, Philip
2014-01-01
Chylous ascites refers to the accumulation of lipid-rich lymph in the peritoneal cavity due to disruption of the lymphatic system secondary to traumatic injury or obstruction. Worldwide, abdominal malignancy, cirrhosis, and tuberculosis are the commonest causes of CA in adults, the latter being most prevalent in developing countries, whereas congenital abnormalities of the lymphatic system and trauma are commonest in children. The presence of a milky, creamy appearing ascitic fluid with triglyceride content above 200 mg/dL is diagnostic, and, in the majority of cases, unless there is a strong suspicion of malignancy, further investigations are not required in patients with cirrhosis. If an underlying cause is identified, targeted therapy is possible, but most cases will be treated conservatively, with dietary support including high-protein and low-fat diets supplemented with medium-chain triglycerides, therapeutic paracentesis, total parenteral nutrition, and somatostatins. Rarely, resistant cases have been treated by transjugular intrahepatic portosystemic shunt, surgical exploration, or peritoneovenous shunt. PMID:27335837
Maeda, N; Horie, Y; Koda, M; Suou, T; Andachi, H; Nakamura, K; Kawasaki, H
1997-01-01
Extrahepatic portal obstruction is one of the causes of portal hypertension, in which well-developed hepatopetal pathways are commonly recognized. Herein an extremely rare case of extrahepatic portal obstruction without hepatopetal pathway, probably caused by arterioportal fistula, is reported. The patient was a normally matured 16-year-old girl admitted for further evaluation of jaundice, presenting with the clinical manifestations of the portal hypertension associated with hypersplenism and portosystemic venous shunt. Celiac angiography clearly demonstrated an intrahepatic arterial aneurysm fed by the right hepatic artery shunting to the superior mesenteric vein, and portography disclosed complete obstruction of the portal trunk with conspicuous hepatofugal pathway but no hepatopetal collateral veins. The exact mechanism of this phenomenon is not known and whether the extrahepatic portal obstruction was primary or secondary is still obscure. However, this is the first case report in the world literature describing extrahepatic portal obstruction with absence of hepatopetal pathway.
The use of cognitive task analysis to improve instructional descriptions of procedures.
Clark, Richard E; Pugh, Carla M; Yates, Kenneth A; Inaba, Kenji; Green, Donald J; Sullivan, Maura E
2012-03-01
Surgical training relies heavily on the ability of expert surgeons to provide complete and accurate descriptions of a complex procedure. However, research from a variety of domains suggests that experts often omit critical information about the judgments, analysis, and decisions they make when solving a difficult problem or performing a complex task. In this study, we compared three methods for capturing surgeons' descriptions of how to perform the procedure for inserting a femoral artery shunt (unaided free-recall, unaided free-recall with simulation, and cognitive task analysis methods) to determine which method produced more accurate and complete results. Cognitive task analysis was approximately 70% more complete and accurate than free-recall and or free-recall during a simulation of the procedure. Ten expert trauma surgeons at a major urban trauma center were interviewed separately and asked to describe how to perform an emergency shunt procedure. Four surgeons provided an unaided free-recall description of the shunt procedure, five surgeons provided an unaided free-recall description of the procedure using visual aids and surgical instruments (simulation), and one (chosen randomly) was interviewed using cognitive task analysis (CTA) methods. An 11th vascular surgeon approved the final CTA protocol. The CTA interview with only one expert surgeon resulted in significantly greater accuracy and completeness of the descriptions compared with the unaided free-recall interviews with multiple expert surgeons. Surgeons in the unaided group omitted nearly 70% of necessary decision steps. In the free-recall group, heavy use of simulation improved surgeons' completeness when describing the steps of the procedure. CTA significantly increases the completeness and accuracy of surgeons' instructional descriptions of surgical procedures. In addition, simulation during unaided free-recall interviews may improve the completeness of interview data. Copyright © 2012 Elsevier Inc. All rights reserved.
Myers, John W; Ghanayem, Nancy S; Cao, Yumei; Simpson, Pippa; Trapp, Katie; Mitchell, Michael E; Tweddell, James S; Woods, Ronald K
2014-02-01
To evaluate outcomes of systemic to pulmonary artery shunts (SPS) in patients weighing less than 3 kg with regard to shunt type, shunt size, and surgical approach. Patients weighing less than 3 kg who underwent modified Blalock-Taussig or central shunts with polytetrafluoroethylene grafts at our institution from January 1, 2000, to May 31, 2011, were reviewed. Patients who had undergone other major concomitant procedures were excluded from the analysis. Primary outcomes included mortality (discharge mortality and mortality before next planned palliative procedure or definitive repair), cardiac arrest and/or extracorporeal membrane oxygenation (ECMO), and shunt reintervention. In this cohort of 80 patients, discharge survival was 96% (77/80). Postoperative cardiac arrest or ECMO occurred in 6/80 (7.5%), and shunt reintervention was required in 14/80 (17%). On univariate analysis, shunt reintervention was more common in patients with 3-mm shunts (11/30, 37%) compared with 3.5-mm (2/36, 6%) or 4-mm shunts (1/14, 7%) (P < .003). There were no statistically significant associations between shunt type, shunt size, or surgical approach and cardiac arrest/ECMO or mortality. Multiple logistic regression demonstrated that a shunt size of 3 mm (P = .019) and extracardiac anomaly (P = .047) were associated with shunt reintervention, whereas no variable was associated with cardiac arrest/ECMO or mortality. In this high-risk group of neonates weighing less than 3 kg at the time of SPS, survival to discharge and the next planned surgical procedure was high. Outcomes were good with the 3.5- and 4-mm shunts; however, shunt reintervention was common with 3-mm shunts. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Yamazaki, Tomosato; Yanaka, Kiyoyuki; Uemura, Kazuya; Tsukada, Atsuro
2004-09-01
A 32-year-old man developed an extremely rare subdural hematoma after syringosubarachnoid shunting for syringomyelia. He presented with a 4-year history of neck pain and spastic paraparesis resulting from T-7 and T-8 vertebral body fracture suffered in a traffic accident at age 22 years. Magnetic resonance imaging revealed syringomyelia between the craniocervical junction and the T-10 level. The symptoms were slowly progressive, and a syringosubarachnoid shunting was performed. His spasticity improved after surgery, but he developed orthostatic headache 7 days after surgery. Magnetic resonance imaging of the brain demonstrated a thin subdural hematoma over the right cerebral convexity. The subdural hematoma resolved spontaneously within a week with conservative treatment. Vigorous cerebrospinal fluid outflow observed during surgery presumably lowered the pressure in the syrinx cavity, leading to significant but transient intracranial hypotension and consequently the formation of subdural hematoma.
Anatomy of hepatic arteriolo-portal venular shunts evaluated by 3D micro-CT imaging.
Kline, Timothy L; Knudsen, Bruce E; Anderson, Jill L; Vercnocke, Andrew J; Jorgensen, Steven M; Ritman, Erik L
2014-06-01
The liver differs from other organs in that two vascular systems deliver its blood - the hepatic artery and the portal vein. However, how the two systems interact is not fully understood. We therefore studied the microvascular geometry of rat liver hepatic artery and portal vein injected with the contrast polymer Microfil(®). Intact isolated rat livers were imaged by micro-CT and anatomic evidence for hepatic arteriolo-portal venular shunts occurring between hepatic artery and portal vein branches was found. Simulations were performed to rule out the possibility of the observed shunts being artifacts resulting from image blurring. In addition, in the case of specimens where only the portal vein was injected, only the portal vein was opacified, whereas in hepatic artery injections, both the hepatic artery and portal vein were opacified. We conclude that mixing of the hepatic artery and portal vein blood can occur proximal to the sinusoidal level, and that the hepatic arteriolo-portal venular shunts may function as a one-way valve-like mechanism, allowing flow only from the hepatic artery to the portal vein (and not the other way around). © 2014 Mayo Foundation Journal of Anatomy © 2014 Anatomical Society.
Clinical features of congenital portosystemic shunt in children.
Kim, Myung Jin; Ko, Jae Sung; Seo, Jeong Kee; Yang, Hye Ran; Chang, Ju Young; Kim, Gi Beom; Cheon, Jung-Eun; Kim, Woo Sun
2012-02-01
Clinical features, images, complications, treatments, and prognosis of 10 children with congenital portosystemic shunt (CPSS) were reviewed. Nine children were diagnosed with intrahepatic shunts while one presented with extrahepatic shunt. CPSS was detected by prenatal ultrasonography in four infants. Three infants presented with galactosemia without an enzyme deficiency. Two children presented with mental retardation and attention deficit hyperactivity disorder. Pulmonary hypertension developed in two patients. Spontaneous closure occurred in four infants with intrahepatic shunts including patent ductus venosus. The shunts were closed using transcatheter embolizations in four patients with intrahepatic shunts. Intrahepatic shunts may close spontaneously. Transcatheter embolization is effective for the treatment of symptomatic intrahepatic shunts.
Cabral, Danielle; Beach, Thomas G; Vedders, Linda; Sue, Lucia I; Jacobson, Sandra; Myers, Kent; Sabbagh, Marwan N
2011-09-01
Normal pressure hydrocephalus (NPH) is considered to be potentially treatable with the placement of a cerebrospinal fluid (CSF) shunt. However, the procedure has been reported to have variable success, particularly with respect to improving the cognitive impairment in NPH. The presence of neurologic comorbidities, particularly Alzheimer's disease (AD), may contribute to shunt responsiveness. Uncovering the extent to which AD and NPH co-occur has implications for diagnosis and treatment of NPH. Autopsy studies of patients with NPH during their lifetime would elucidate the frequency of such comorbidities. A search of the Sun Health Research Institute Brain Donation Program database was conducted between January 1, 1997 and April 1, 2009 to identify all cases with neuropathologic evidence of dementia as well as those of clinically diagnosed NPH. We reviewed the medical records and brain findings of each NPH case. Of the 761 cases autopsied over the study interval, 563 were found to have neuropathologic evidence meeting criteria for a dementing illness. Of 563 cases, AD was found exclusively in 313 (56%), and 94 suffered from secondary diagnosis of dementia. Nine of 761 cases were identified with a clinical diagnosis of NPH, which were among the 563 cases with neuropathology of dementing illness at autopsy, representing 1.6% (9/563) of the cases. On review of brain autopsy reports of these nine patients, eight (89%) were found to have AD and one (11%) had progressive supranuclear palsy. Review of the medical records of the nine NPH cases revealed the following clinical comorbidities: five suffered from AD, one from Parkinson's Disease, one from mild cognitive impairment, and one from seizure disorder. Given the findings of the present study, we support the AD-NPH theory and posit that AD is a common pathologic comorbidity in the setting of NPH and may preclude cognitive improvement postshunt placement. This may influence the selection of cases for shunting in the future. Copyright © 2011 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.
A prospective study of basal insulin concentrations in dogs with congenital portosystemic shunts.
Collings, A J; Gow, A G; Marques, A; Yool, D; Furneaux, R; Mellanby, R; Watson, P J
2012-04-01
Hypoglycaemia is a common cause of morbidity in dogs with congenital portosystemic shunts but the aetiology is unknown. The hypothesis of this study was that dogs with congenital portosystemic shunts would have significantly higher insulin concentrations than dogs without congenital portosystemic shunts. The main objective of the study was to compare peripheral glucose and insulin concentrations between dogs with congenital portosystemic shunts and dogs without congenital portosystemic shunts. Peripheral serum insulin and plasma glucose concentrations were measured in dogs with congenital portosystemic shunts and without congenital portosystemic shunts and compared both between groups as well as to reference intervals derived from healthy dogs. Congenital portosystemic shunts were diagnosed in 41 dogs. Forty-eight dogs hospitalised with other conditions acted as controls. Serum insulin concentrations were mildly elevated (Ä40 μU/mL) in seven dogs and were markedly elevated in two dogs with congenital portosystemic shunts, yet mild hypoglycaemia (3·3 mmol/L) was detected in only one of these dogs. Four dogs with congenital portosystemic shunts showed fasting hypoglycaemia, yet insulin concentrations were within or below the reference interval in three. There was no difference between the median insulin concentration of dogs with congenital portosystemic shunts and without congenital portosystemic shunts. Hyperinsulinaemia is infrequently observed in dogs with congenital portosystemic shunts. The aetiology of hypoglycaemia in dogs with congenital portosystemic shunts merits further investigation. © 2012 British Small Animal Veterinary Association.
Petridis, Ioannis; Miraglia, Roberto; Marrone, Gianluca; Gruttadauria, Salvatore; Luca, Angelo; Vizzini, Giovanni Battista; Gridelli, Bruno
2010-03-07
Transjugular intrahepatic portosystemic shunt (TIPSS) is considered a valid therapeutic option for the treatment of portal hypertension and its complications. The guidelines for this procedure have already been established on the basis of the normal vascular anatomy and of various technical radiological aspects. In some few rare cases, diagnosis of a congenital vascular anomaly can be made accidentally by interventional radiologists, making the procedure of the TIPSS placement extremely difficult or in some cases technically impossible. This report describes a rare vascular malformation characterized by the absence of the right superior vena cava and persistence of the left superior vena cava in a patient with a diagnosis of advanced liver cirrhosis who needed a TIPSS placement in order to control refractory ascites.
Ventriculoperitoneal shunt - discharge
... ventriculoperitoneal - discharge; VP shunt - discharge; Shunt revision - discharge; Hydrocephalus shunt placement - discharge ... Your child has hydrocephalus and needed a shunt placed to drain excess fluid and relieve pressure in the brain. This buildup of brain ...
Wilmshurst, Peter T; Morrison, W Lindsay; Walsh, Kevin P
2015-06-01
Decompression illness (DCI) is associated with a right-to-left shunt, such as persistent foramen ovale (PFO), atrial septal defect (ASD) and pulmonary arteriovenous malformations. About one-quarter of the population have a PFO, but considerably less than one-quarter of divers suffer DCI. Our aim was to determine whether shunt-related DCI occurs mainly or entirely in divers with the largest diameter atrial defects. Case control comparison of diameters of atrial defects (PFO and ASD) in 200 consecutive divers who had transcatheter closure of an atrial defect following shunt-related DCI and in an historic group of 263 individuals in whom PFO diameter was measured at post-mortem examination. In the divers who had experienced DCI, the median atrial defect diameter was 10 mm and the mean (standard deviation) was 9.9 (3.6) mm. Among those in the general population who had a PFO, the median diameter was 5 mm and mean was 4.9 (2.6) mm. The difference between the two groups was highly significant (P < 0.0001). Of divers with shunt-related DCI, 101 (50.5%) had an atrial defect 10 mm diameter or larger, but only 1.3% of the general population studied had a PFO that was 10 mm diameter of larger. The risk of a diver suffering DCI is related to the size of the atrial defect rather than just the presence of a defect.
Sweeping shunted electro-magnetic tuneable vibration absorber: Design and implementation
NASA Astrophysics Data System (ADS)
Turco, E.; Gardonio, P.
2017-10-01
This paper presents a study on the design and implementation of a time-varying shunted electro-magnetic Tuneable Vibration Absorber for broad-band vibration control of thin structures. A time-varying RL-shunt is used to harmonically vary the stiffness and damping properties of the Tuneable Vibration Absorber so that its mechanical fundamental natural frequency is continuously swept in a given broad frequency band whereas its mechanical damping is continuously adapted to maximize the vibration absorption from the hosting structure where it is mounted. The paper first recalls the tuning and positioning criteria for the case where a classical Tuneable Vibration Absorber is installed on a thin walled cylindrical structure to reduce the response of a resonating flexural mode. It then discusses the design of the time-varying shunt circuit to produce the desired stiffness and damping variations in the electro-magnetic Tuneable Vibration Absorber. Finally, it presents a numerical study on the flexural vibration and interior sound control effects produced when an array of these shunted electro-magnetic Tuneable Vibration Absorbers are mounted on a thin walled cylinder subject to a rain-on-the-roof stochastic excitation. The study shows that the array of proposed systems effectively controls the cylinder flexural response and interior noise over a broad frequency band without need of tuning and thus system identification of the structure. Therefore, the systems can be successfully used also on structures whose physical properties vary in time because of temperature changes or tensioning effects for example.
Vibration Control via Stiffness Switching of Magnetostrictive Transducers
NASA Technical Reports Server (NTRS)
Scheidler, Justin J.; Asnani, Vivake M.; Dapino, Marcelo J.
2016-01-01
In this paper, a computational study is presented of structural vibration control that is realized by switching a magnetostrictive transducer between high and low stiffness states. Switching is accomplished by either changing the applied magnetic field with a voltage excitation or changing the shunt impedance on the transducer's coil (i.e., the magnetostrictive material's magnetic boundary condition). Switched-stiffness vibration control is simulated using a lumped mass supported by a damper and the magnetostrictive transducer (mount), which is represented by a nonlinear, electromechanical model. Free vibration of the mass is calculated while varying the mount's stiffness according to a reference switched-stiffness vibration control law. The results reveal that switching the magnetic field produces the desired change in stiffness, but also an undesired actuation force that can significantly degrade the vibration control. Hence, a modified switched-stiffness control law that accounts for the actuation force is proposed and implemented for voltage-controlled stiffness switching. The influence of the magneto-mechanical bias condition is also discussed. Voltage-controlled stiffness switching is found to introduce damping equivalent to a viscous damping factor up to about 0.13; this is shown to primarily result from active vibration reduction caused by the actuation force. The merit of magnetostrictive switched-stiffness vibration control is then quantified by comparing the results of voltage- and shunt-controlled stiffness switching to the performance of optimal magnetostrictive shunt damping. For the cases considered, optimal resistive shunt damping performed considerably better than both voltage- and shunt-controlled stiffness switching.
Zachenhofer, Iris; Donat, Markus; Roessler, Karl
2012-04-01
In order to avoid occurrence of post-operative hygromas in specific hydrocephalus patients being at high risk of overdrainage, a combination of programmable valve and anti-gravity device is widely recommended. We analyzed our series of hydrocephalus patients implanted with such a shunt configuration focusing on complications in relation to over-/underdrainage and neurological outcome. In 28 hydrocephalic patients (14 women and 14 men; mean age 65 years, range from 14 to 82 years; 11 normal pressure, 7 post-traumatic, and 4 post-hemorrhagic hydrocephalus), a Codman Medos programmable valve combined with a Miethke shunt assistant (SA) was implanted at the Department of Neurosurgery of the Academic Teaching Hospital Feldkirch. Implantation was performed simultaneously in 20 patients during the primary procedure: in five patients, SA was placed during revision surgery, and in three patients, the patent system was completed by additional implantation of an SA. Subdural hematoma occurred in one out of 20 patients with SA implantation during primary procedure and in two out of eight patients with SA implantation as secondary procedure, respectively. Shunt occlusion occurred in one patient out of the patients with SA implantation during primary procedure, but was seen in three patients with pre-existing shunt without SA. Shunt infection occurred in one case. Our results suggest the combination of an adjustable valve and SA as an effective treatment for a specific group of hydrocephalus patients being at high risk for overdrainage.
Rheolytic thrombectomy: possibilities and first results.
Zatevakhin, I I; Shipovskiĭ, V N; Zolkin, V N; Nechaev, A I; Piliposian, E A
2008-01-01
The present study was undertaken to investigate the possibilities of using the method of rheolytic thrombectomy (hereinafter referred to as RTE) in surgical practice, and to assess its immediate outcomes in treatment of thromboses of arteries and veins of the lower extremities, as well as transjugular intrahepatic portosystemic shunts (hereinafter referred to as TIPS). We have gained experience in carrying out a total of 33 rheolytic thrombectomies with the help of the system JET 9000 (R) using the Xpeedior catheter in a total of thirty-one 43-to-87-year-old patients. Twenty-four interventions were performed for acute thromboses of arteries and shunts of the lower limbs, five - in patients presenting with floating thrombi in the inferior vena cava, and four operations were carried out in patients diagnosed with thrombosis of the segment after TIPS. In the group of the patients with thromboses of the arteries of the lower limbs (n=19), in 16 patients RTE resulted in restoration of >50% of the arterial lumen. In three patients of the same group, we managed to restore the lumen by only 50% and less. In the group of patients with thromboses of the shunts (n=5), RTE with a successful angiographic outcome was performed in three patients. In yet another patient, the lumen was restored only by 50%, and in a further one patient, the lumen of the shunt we failed to restore. Nineteen patients underwent a total of 13 balloon angioplasties (BA), 4 stenting interventions, and 2 regional thrombolytic procedures. Two patients after RTE and V A were subjected to postdilatational endarterectomy. In one patient RTE from the shunt was supplemented with plasty of its proximal anastomosis with a synthetic patch. In two patients, RTE was complicated by embolism of the deep femoral artery. In the group consisting of five patients diagnosed with floating thrombi of the inferior vena cava, a successful outcome was observed only in two. In patients presenting with thromboses of the stems following TIPS in all the cases we managed to completely restore patency of the shunts. Later on, three patients were found to have developed rethrombosis of the shunt. In two cases after RTE, haemolysis was observed to ensue, followed by the development of acute renal insufficiency. The remote results were followed up in the group of the patients with thromboses of the arteries and shunts of the lower limbs within the terms up to 24 months. Patency of the remodelled segments was preserved in seventeen patients (77.3%), and five patients (22.7%) were subjected to amputation of the affected lower extremity. Hence, the initial experience gained in using RTE gives certain hopes in treatment of patients presenting with acute arterial and venous thromboses of various localization, owing to its due safety, minimally invasive nature, and high efficiency, especially in patients with severe accompanying pathology.
Temporary arterial shunts to maintain limb perfusion after arterial injury: an animal study
NASA Technical Reports Server (NTRS)
Dawson, D. L.; Putnam, A. T.; Light, J. T.; Ihnat, D. M.; Kissinger, D. P.; Rasmussen, T. E.; Bradley, D. V. Jr
1999-01-01
BACKGROUND: Temporary shunt placement can quickly restore perfusion after extremity arterial injury. This study examined the adequacy of limb blood flow with shunt use, non-heparin-bonded shunt patency over prolonged periods, and the safety of this technique. METHODS: Common iliac arteries were divided and 4.0-mm Silastic Sundt shunts placed in 16 anesthetized pigs. Eight (group I) had shunts placed immediately; eight others (group II) were shunted after an hour of limb ischemia and hemorrhagic shock. Physiologic parameters and femoral artery blood flow in both hindlimbs were continuously monitored. Limb lactic acid generation, oxygen utilization, and hematologic and metabolic effects were serially evaluated for 24 hours. RESULTS: Shunts remained patent in 13 of 16 pigs. Shunts thrombosed in two group I animals because of technical errors, but functioned well after thrombectomy and repositioning. Patency could not be maintained in one animal that died from shock. Flow in group I shunted limbs was 57 (+/-11 SD) % of control. For group II animals in shock, shunted limb flow initially averaged 46 +/- 15% of control, but 4 hours after shunt placement, the mean limb blood flow was the same as in group I. Increased oxygen extraction compensated for the lower flow. Lactic acid production was not increased in comparison to control limbs. CONCLUSION: Shunts provided adequate flow in this model of extremity trauma. Correctly placed shunts stayed patent for 24 hours, without anticoagulation, if shunt placement followed resuscitation.
Programmable valve shunts: are they really better?
Kataria, Rashim; Kumar, Vimal; Mehta, Veer Singh
2012-01-01
Programmable valve shunts allows selection of opening pressure of shunt valve. In the presented article, a unique complication pertaining to programmable shunts has been discussed. A 5-year-old boy who had tectal plate low grade glioma with obstructive hydrocephalus was managed with Codman programmable ventriculoperitoneal shunt. There was a spontaneous change in the opening pressure of the shunt valve leading to shunt malfunction. Routinely used household appliances produce a magnetic field strong enough to cause change in the setting of shunt valve pressure and may lead to valve malfunction. Other causes of programmable valve malfunction also discussed.
A critical appraisal of drainage in syringomyelia.
Sgouros, S; Williams, B
1995-01-01
The use of drains in the treatment of syringomyelia has a simple and immediate appeal and has been practiced widely since the report of Abbe and Coley over 100 years ago. Good short-term results have been claimed in the past, but long-term outcome is largely unknown. An experience in Birmingham, England is reviewed in which 73 patients who had had some form of syrinx drainage procedure performed were subsequently followed up. In these cases, a total of 56 syringopleural and 14 syringosubarachnoid shunts had been inserted. Ten years after the operations, only 53.5% and 50% of the patients, respectively, continued to remain clinically stable. A 15.7% complication rate was recorded, including fatal hemorrhage, infection, and displacement of the drain from the pleural and syrinx cavities. At second operation or necropsy, at least 5% of shunts were discovered to be blocked. The effect of other drainage procedures that do not use artificial tubing, such as syringotomy and terminal ventriculostomy, was analyzed but found not to offer any substantial benefit. These results indicate that drainage procedures are not an effective solution to remedying the progressive, destructive nature of syringomyelia. It is suggested that, rather than attempting to drain the syrinx cavity, disabling the filling mechanism of the syrinx is more appropriate. Most forms of syringomyelia have a blockage at the level of the foramen magnum or in the subarachnoid space of the spine. Surgical measures that aim to reconstruct the continuity of the subarachnoid space at the site of the block are strongly recommended. Lowering the overall pressure of the cerebrospinal fluid is advocated when reestablishment of the pathways proves impossible. Syrinx drainage as an adjuvant to more physiological surgery may have a place in the treatment of syringomyelia. If two procedures are done at the same time, however, it is difficult to ascribe with certainty a success or failure, and it is suggested that the drainage procedure be reserved for a later attempt if the elective first operation fails.
NASA Astrophysics Data System (ADS)
Ludwig, Hans C.; Kruschat, Thomas; Knobloch, Torsten; Rostasy, Kevin; Buchfelder, Michael
2005-04-01
Preterm infants have a high incidence of post hemorrhagic or post infectious hydrocephalus often associated with ventricular or arachnoic cysts which carry a high risk of entrapment of cerebrospinal fluid (CSF). In these cases fenestration and opening of windows within the separating membranes are neurosurgical options. Although Nd:YAG- and diode-lasers have already been used in neuroendoscopic procedures, neurosurgeons avoid the use of high energy lasers in proximity to vital structures because of potential side effects. We have used a recently developed diode pumped solid state (DPSS) laser emitting light at a wavelength of 2.0 μm (Revolix TM LISA laser products, Katlenburg, Germany), which can be delivered through silica fibres towards endoscopic targets. From July 2002 until June 2004 fourteen endoscopic procedures in 12 consecutive patients (age 3 months to 12 years old) were performed. Most children suffered from complex post hemorrhagic and post infectious hydrocephalus, in whom ventriculoperitoneal shunt devices failed to restore a CSF equilibrium due to entrapment of CSF pathways by the cysts. We used two different endoscopes, a 6 mm Neuroendoscope (Braun Aesculap, Melsungen, Germany; a 4 mm miniature Neuroscope (Storz, Tuttlingen, Germany). The endoscopes were connected to a standard camera and TV monitor, the laser energy was introduced through a 365 μm core diameter bare ended silica fibre (PercuFib, LISA laser products, Katlenburg, Germany) through the endoscope"s working channel. The continuous wave laser was operated at power levels from 5 to 15 Watt in continuous and chopped mode. The frequency of the laser in chopped mode was varied between 5 and 20 Hz. All patients tolerated the procedure well. No immediate or long term side effects were noted. In 3 patients with cystic compression of the 4th ventricle, insertion of a shunt device could be avoided. The authors conclude that the use of the new RevolixTM laser enables safe and effective procedures in neuroendoscopy.
Embolization of Bleeding Stomal Varices by Direct Percutaneous Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arulraj, Ramakrishnan, E-mail: arulraas@yahoo.com; Mangat, Kamarjit S., E-mail: Kamarjit.mangat@uhb.nhs.uk; Tripathi, Dhiraj, E-mail: d.tripathi@bham.ac.uk
2011-02-15
Stomal varices can occur in patients with stoma in the presence of portal hypertension. Suture ligation, sclerotherapy, angiographic embolization, stoma revision, beta blockade, portosystemic shunt, and liver transplantation have been described as therapeutic options for bleeding stomal varices. We report the case of a 21-year-old patient with primary sclerosing cholangitis and colectomy with ileostomy for ulcerative colitis, where stomal variceal bleeding was successfully treated by direct percutaneous embolization. We consider percutaneous embolization to be an effective way of treating acute stomal bleeding in decompensated patients while awaiting decisions regarding shunt procedures or liver transplantation.
Valentini, L; Solero, C L; Lasio, G; Giombini, S; Visintini, S; Balestrini, M R; Giordano, L; Grisoli, M
1995-03-01
The authors review 71 patients with triventricular hydrocephalus in whom a contrast-enhanced CT scan did not show any tumoral or vascular lesion that could have caused the hydrocephalus. The patients were subdivided into three age groups. The results of the neuroradiological examination, the surgical treatment, and the complications of the shunt procedure are analyzed, with special reference to the high number (13) of periaqueductal alterations of signal pattern found on MRI (interpreted as a "slow growing" neoplasm) and to the incidence and causes of shunt malfunction.
Superconducting fault current-limiter with variable shunt impedance
Llambes, Juan Carlos H; Xiong, Xuming
2013-11-19
A superconducting fault current-limiter is provided, including a superconducting element configured to resistively or inductively limit a fault current, and one or more variable-impedance shunts electrically coupled in parallel with the superconducting element. The variable-impedance shunt(s) is configured to present a first impedance during a superconducting state of the superconducting element and a second impedance during a normal resistive state of the superconducting element. The superconducting element transitions from the superconducting state to the normal resistive state responsive to the fault current, and responsive thereto, the variable-impedance shunt(s) transitions from the first to the second impedance. The second impedance of the variable-impedance shunt(s) is a lower impedance than the first impedance, which facilitates current flow through the variable-impedance shunt(s) during a recovery transition of the superconducting element from the normal resistive state to the superconducting state, and thus, facilitates recovery of the superconducting element under load.
The clinical anatomy of congenital portosystemic venous shunts.
Stringer, Mark D
2008-03-01
Congenital portosystemic venous shunts are rare. Their gross anatomy has not been well defined. Four different varieties of congenital portosystemic venous shunts are described in six children seen during a 10-year period, focusing on the anatomy of the shunt as determined by imaging studies and surgery. A detailed review of the literature indicates that congenital portosystemic venous shunts are best classified as: extrahepatic or intrahepatic. Extrahepatic shunts may be further subdivided into portocaval shunts (type 1 end-to-side and type 2 side-to-side) and others. Intrahepatic shunts are due to an abnormal intrahepatic connection between the portal vein and hepatic vein/inferior vena cava or a persistent patent ductus venosus. Additional congenital anomalies, particularly cardiac malformations, may be associated with any type. Some congenital intrahepatic portosystemic venous shunts close spontaneously in infancy; all other congenital portosystemic venous shunts tend to remain patent. To a variable extent, depending largely on the volume and duration of the shunt, affected individuals are at risk of developing hepatic encephalopathy and/or an intrahepatic tumor. The key to understanding the pathogenesis of these shunts lies in the normal developmental mechanisms underlying the formation of the portal vein and inferior vena cava in the embryo. Copyright 2008 Wiley-Liss, Inc.
Dupepe, Esther B; Hopson, Betsy; Johnston, James M; Rozzelle, Curtis J; Jerry Oakes, W; Blount, Jeffrey P; Rocque, Brandon G
2016-11-01
OBJECTIVE It is generally accepted that cerebrospinal fluid shunts fail most frequently in the first years of life. The purpose of this study was to describe the risk of shunt failure for a given patient age in a well-defined cohort with shunted hydrocephalus due to myelomeningocele (MMC). METHODS The authors analyzed data from their institutional spina bifida research database including all patients with MMC and shunted hydrocephalus. For the entire population, the number of shunt revisions in each year of life was determined. Then the number of patients at risk for shunt revision during each year of life was calculated, thus enabling them to calculate the rate of shunt revision per patient in each year of life. In this way, the timing of all shunt revision operations for the entire clinic population and the likelihood of having a shunt revision during each year of life were calculated. RESULTS A total of 655 patients were enrolled in the spina bifida research database, 519 of whom had a diagnosis of MMC and whose mean age was 17.48 ± 11.7 years (median 16 years, range 0-63 years). Four hundred seventeen patients had had a CSF shunt for the treatment of hydrocephalus and thus are included in this analysis. There were 94 shunt revisions in the 1st year of life, which represents a rate of 0.23 revisions per patient in that year. The rate of shunt revision per patient-year initially decreased as age increased, except for an increase in revision frequency in the early teen years. Shunt revisions continued to occur as late as 43 years of age. CONCLUSIONS These data substantiate the idea that shunt revision surgeries in patients with MMC are most common in the 1st year of life and decrease thereafter, except for an increase in the early teen years. A persistent risk of shunt failure was observed well into adult life. These findings underscore the importance of routine follow-up of all MMC patients with shunted hydrocephalus and will aid in counseling patients and families.
Bermo, Mohammed; Matesan, Manuela C; Itani, Malak; Behnia, Fatemeh; Vesselle, Hubert J
2018-04-09
The purpose of the study was to correlate lung shunt fraction (LSF) calculated by intra-arterial injection of Technetium-99m (Tc-99m)-labeled macroaggregated albumin (MAA) in a hepatic artery branch with the presence of certain patterns of vascular shunts on dynamic CT or MRI of the liver. This retrospective study was approved by the institutional review board and informed consent was waived. We reviewed 523 MAA scans in 453 patients (301 men, 152 women) performed from July 2007 to June 2015 and their correlative cross-sectional imaging. Patterns of vascular shunts on dynamic CT or MRI performed within 3 months of the MAA study and that potentially divert hepatic arterial inflow to the systemic venous return were defined as "target shunts." Dynamic CT or MRI was classified into three groups with target shunt present, absent, or indeterminate. The mean LSF was compared across the first and second groups using paired t test. 342 CT and MRI studies met inclusion criteria: target shunts were present in 63 studies, absent in 271 studies, and 8 studies were indeterminate. When target shunts were visualized, the mean LSF on corresponding MAA scans was 12.9 ± 10.36% (95% CI 10.29-15.15%) compared to 4.3 ± 3.17% (95% CI 3.93-4.68%) when no target shunt was visualized. The difference was statistically significant (p value < 0.001). Identified target shunts were either direct (arteriohepatic venous shunt) or indirect (arterioportal shunt combined with a portosystemic shunt). Visualizing certain patterns of vascular shunting on a dynamic CT or MRI scan is associated with high LSF.
Habibi, Zohreh; Ertiaei, Abolhasan; Nikdad, Mohammad Sadegh; Mirmohseni, Atefeh Sadat; Afarideh, Mohsen; Heidari, Vahid; Saberi, Hooshang; Rezaei, Abdolreza Sheikh; Nejat, Farideh
2016-11-01
The relationships between shunt infection and predictive factors have not been previously investigated using Artificial Neural Network (ANN) model. The aim of this study was to develop an ANN model to predict shunt infection in a group of children with shunted hydrocephalus. Among more than 800 ventriculoperitoneal shunt procedures which had been performed between April 2000 and April 2011, 68 patients with shunt infection and 80 controls that fulfilled a set of meticulous inclusion/exclusion criteria were consecutively enrolled. Univariate analysis was performed for a long list of risk factors, and those with p value < 0.2 were used to create ANN and logistic regression (LR) models. Five variables including birth weight, age at the first shunting, shunt revision, prematurity, and myelomeningocele were significantly associated with shunt infection via univariate analysis, and two other variables (intraventricular hemorrhage and coincided infections) had a p value of less than 0.2. Using these seven input variables, ANN and LR models predicted shunt infection with an accuracy of 83.1 % (AUC; 91.98 %, 95 % CI) and 55.7 % (AUC; 76.5, 95 % CI), respectively. The contribution of the factors in the predictive performance of ANN in descending order was history of shunt revision, low birth weight (under 2000 g), history of prematurity, the age at the first shunt procedure, history of intraventricular hemorrhage, history of myelomeningocele, and coinfection. The findings show that artificial neural networks can predict shunt infection with a high level of accuracy in children with shunted hydrocephalus. Also, the contribution of different risk factors in the prediction of shunt infection can be determined using the trained network.
Basile, Antonio; Failla, Giovanni; La Vignera, Sandro; Condorelli, Rosita Angela; Calogero, Aldo; Vicari, Enzo; Granata, Antonio; Mundo, Elena; Caltabiano, Giuseppe; Pizzarelli, Marco; Messina, Martina; Scavone, Giovanni; Lanzafame, Franz; Iezzi, Roberto; Tsetis, Dimitrios
2015-05-01
The aim of this study was to compare the technical success between left spermatic vein (LSV) scleroembolisation achieved with the injection of sclerosant through a diagnostic catheter and through an occluding balloon (OB), in the treatment of male varicocele. From January 2012 to September 2013, we prospectively enrolled 100 patients with left varicocele and an indication for LSV scleroembolisation related to symptoms or spermiogram anomalies; patients were randomised to two groups (we wrote a list of 100 lines assigned casually with A or B and each patient was consecutively allocated to group A or B on the basis of this list). Patients in group A underwent injection of the sclerosing agent through an angiographic diagnostic catheter (free catheter technique) and patients in group B through an OB catheter (OB technique). In cases of incomplete occlusion of the LSV, the procedure was completed with coils. Total occlusion of the LSV at post-treatment phlebography during a Valsalva manoeuvre before any coil embolisation was considered a technical success. The rate of complications was also evaluated. The Fischer's test was used for statistical analysis. We evaluated a total of 90 patients because five patients for each group were not included in the statistical analysis owing to technical problems or complications. In group A we had a technical success of 75.6 versus 93.4 % in group B, and the difference was statistically significant (P = 0.003); in particular, we had to complete the embolisation with insertion of coils in 11 cases (24.4 %) in group A, and in three cases in group B (6.6 %). In group A, LSV rupture occurred in four cases (8 %) so the procedure was completed by sclerosant injection through the OB located distally to the lesion. These patients were not considered for evaluation. In another case, a high flow shunt towards the inferior vena cava was detected, so the patient underwent OB injection to stop the flow to the shunt, and was not included for statistical evaluation. In group B, vein rupture with contrast leakage was noted in six cases (12 %); nonetheless, all the procedures were completed because the OB was positioned distally to the vessel tear, obviating any retrograde leakage of sclerosant. In group B, in five cases (10 %), we were unable to advance the OB though the LSV ostium so the procedures were completed with the diagnostic catheter and not considered for statistical evaluation. On the basis of our data, the embolisation of the LSV obtained by injecting the sclerosant through an OB rather than through a diagnostic catheter seems to be more effective in achieving total vein embolisation, as well as allowing a controlled injection of sclerosant even in cases of vein rupture.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bahramipour, Phillip F.; Festa, Steven; Biswal, Rajiv
Though polycystic liver disease (PCLD) has historically been considered a contraindication to TIPS, we present a case where technically successful shunt creation was achieved without the need for modification of the standard TIPS procedure, as was required in a previous report.
Delle Chiaie, L; Neuberger, P; Von Kalle, T
2008-08-01
Congenital intrahepatic portosystemic shunts (IPSS) are abnormal vascular communications within the liver between branches of the portal vein and the hepatic veins. They have been recognized as an important disorder in children and should be differentiated from metabolic diseases, the symptoms of which may be similar. Several cases of prenatal diagnosis of abnormalities of the fetal venous system have been described in the literature, but the significance and prognosis of isolated congenital IPSS in prenatal life have not been reported and have only been derived from children. We present a case of congenital IPSS in which there was severe intrauterine growth restriction with a concomitant atypical fetal Doppler pattern. Findings on Doppler ultrasound indicate that the prenatal diagnosis of congenital IPSS is now feasible. (c) 2008 ISUOG. Published by John Wiley & Sons, Ltd.
Portosystemic shunt as a cause of congenital hyperinsulinemic hypoglycemia.
Yoshii, Keisuke; Noda, Masahiro; Naiki, Yasuhiro; Horikawa, Reiko
2017-04-01
Congenital hyperinsulinemic hypoglycemia (CHH) is characterized by the inappropriate secretion of insulin from pancreatic beta cells in the presence of hypoglycemia. We herein describe the case of a 5-month-old boy with CHH due to congenital portosystemic shunt (CPSS). Insulin secreted from pancreatic beta cells flows into the portal vein and is first metabolized in the liver. First-pass elimination of insulin in the liver leads to great decrease in insulin concentration by approximately 40-80% in humans. CPSS accounts for a large quantity of insulin delivery into the systemic circulation due to the lack of hepatic first-pass elimination. Hypoglycemia can result from consistently high levels of insulin after reaching normal glucose level. CPSS therefore should be considered as a rare cause of CHH, especially in the case of post-prandial hyperinsulinemic hypoglycemia. © 2017 Japan Pediatric Society.
Pulse pressure waveform in hydrocephalus: what it is and what it isn't.
Czosnyka, Marek; Czosnyka, Zofia; Keong, Nicole; Lavinio, Andreas; Smielewski, Piotr; Momjian, Shahan; Schmidt, Eric A; Petrella, Gianpaolo; Owler, Brian; Pickard, John D
2007-04-15
Apart from its mean value, the pulse waveform of intracranial pressure (ICP) is an essential element of pressure recording. The authors reviewed their experience with the measurement and interpretation of ICP pulse amplitude by referring to a database of recordings in hydrocephalic patients. The database contained computerized pressure recordings from 2100 infusion studies (either lumbar or intraventricular) or overnight ICP monitoring sessions in patients suffering from hydrocephalus of various types (both communicating and noncommunicating), origins, and stages of management (shunt or no shunt). Amplitude was calculated from ICP waveforms by using a spectral analysis methodology. The appearance of a pulse waveform amplitude is positive evidence of a technically correct recording of ICP and helps to distinguish between postural and vasogenic variations in ICP. Pulse amplitude is significantly correlated with the amplitude of cerebral blood flow velocity (R = 0.4, p = 0.012) as assessed using Doppler ultrasonography. Amplitude is positively correlated with a mean ICP (R = 0.21 in idiopathic normal-pressure hydrocephalus [NPH]; number of cases 131; p < 0.01) and resistance to cerebrospinal fluid outflow (R = 0.22) but does not seem to be correlated with cerebrospinal elasticity, dilation of ventricles, or severity of hydrocephalus (NPH score). Amplitude increases slightly with age (R = 0.39, p < 0.01; number of cases 46). A positive association between pulse amplitude and increased ICP during an infusion study is helpful in distinguishing between hydrocephalus and predominant brain atrophy. A large amplitude is associated with a good outcome after shunting (positive predictive power 0.9), whereas a low amplitude has no predictive power in outcome prognostication (0.5). Pulse amplitude is reduced by a properly functioning shunt. Proper recording, detection, and interpretation of ICP pulse waveforms provide clinically useful information about patients suffering from hydrocephalus.
Kiefer, J; Weber, A; Pfennigdorff, T; von Ilberg, C
2000-01-01
Insertion of a sufficient number of electrodes is important for a successful use of cochlear implants. We investigated the results of scala vestibuli insertion for cochlear implantation in cases of obstructed scala tympani. In a series of 200 cochlear implantations, scala vestibuli insertion was successfully performed in 4 cases with obstruction of the scala tympani. Etiologies included a temporal bone fracture, severe otosclerosis and malformations of the cochlea. The maximum insertion depth obtained via the scala vestibuli was 30 mm. Postoperative results were comparable to patients in whom conventional scala tympani insertion was performed. No adverse effects related to the site of insertion were observed. Scala vestibuli insertion offers a valuable alternative in cases of obstructed scala tympani that can be employed for a variety of etiologies. Copyright 2000 S. Karger AG, Basel
Ben-Sira, Liat; Shiran, Shelly I; Pratt, Li-Tal; Precel, Ronit; Ovadia, Dror; Constantini, Shlomi; Roth, Jonathan
2018-05-04
Shunt series (SS) are a common diagnostic tool used to verify shunt integrity. SS include X-ray films of the skull, chest, and abdomen and often are performed either when a shunted patient presents with suspected shunt malfunction or as a screening test to identify shunt disconnections or dislodgment. EOS low-dose biplanar X-rays are associated with significantly reduced radiation doses compared with ordinary X-rays and are used for various indications. This is the first publication on the use of EOS as a SS technique. Over a period of 6 months, EOS were performed at our center for various orthopedic indications, mostly for scoliosis evaluation. Nine children (<20 years of age) had a ventriculoperitoneal shunt and served as the study group. We retrospectively reviewed shunt visibility and integrity in the EOS scans as well as regular SS or plain spinal X-rays. Three patients had bilateral shunts, and 8 had previous X-rays for comparison. In all patients, the shunt integrity was easily demonstrated on the EOS images. Two patients had an identified shunt disconnection confirmed on the EOS images. No shunt-related information was missed on the EOS compared with the other X-ray images. These preliminary results suggest that EOS may be used as an alternative technology to demonstrate shunt integrity instead of regular X-ray SS. Favorable shunt visibility without the need for multiple radiation exposures and image processing (such as stitching) results in a significantly shorter examination time and significant less radiation. Copyright © 2018 Elsevier Inc. All rights reserved.
Yang, Heechul; Lee, Chun Kyon; Kim, Gun Bea
2016-01-01
Purpose To evaluate the technical feasibility and safety of vascular plug assisted retrograde transvenous obliteration (PARTO) for bleeding gastric varix performed in the emergent clinical setting and describe the mid-term clinical results. Materials and Methods From April 2012 to January 2015, emergent PARTO was tried in total 9 patients presented with active gastric varix bleeding. After initial insufficient or failure of endoscopic approach, they underwent PARTO in the emergent clinical setting. Gelatin sponge embolization of both gastrorenal (GR) shunt and gastric varix was performed after retrograde transvenous placement of a vascular plug in GR shunt. Coil assisted RTO (CARTO) was performed in one patient who had challenging GR shunt anatomy for vascular plug placement. Additional embolic materials, such as microcoils and NBCA glue-lipiodol mixture, were required in three patients to enhance complete occlusion of GR shunt or obliteration of competitive collateral vessels. Clinical success was defined as no variceal rebleeding and disappearance of gastric varix. Results All technical and clinical success–i.e., complete GR shunt occlusion and offending gastric varix embolization with immediate bleeding control–was achieved in all 9 patients. There was no procedure-related complication. All cases showed successful clinical outcome during mean follow up of 17 months (12–32 months), evidenced by imaging studies, endoscopy and clinical data. In 4 patients, mild worsening of esophageal varices or transient ascites was noted as portal hypertensive related change. Conclusion Emergent PARTO is technically feasible and safe, with acceptable mid-term clinical results, in treating active gastric varix bleeding. PMID:27189294
New and improved ways to treat hydrocephalus: Pursuit of a smart shunt.
Lutz, Barry R; Venkataraman, Pranav; Browd, Samuel R
2013-01-01
The most common treatment for hydrocephalus is placement of a cerebrospinal fluid shunt to supplement or replace lost drainage capacity. Shunts are life-saving devices but are notorious for high failure rates, difficulty of diagnosing failure, and limited control options. Shunt designs have changed little since their introduction in 1950s, and the few changes introduced have had little to no impact on these long-standing problems. For decades, the community has envisioned a "smart shunt" that could provide advanced control, diagnostics, and communication based on implanted sensors, feedback control, and telemetry. The most emphasized contribution of smart shunts is the potential for advanced control algorithms, such as weaning from shunt dependency and personalized control. With sensor-based control comes the opportunity to provide data to the physician on patient condition and shunt function, perhaps even by a smart phone. An often ignored but highly valuable contribution would be designs that correct the high failure rates of existing shunts. Despite the long history and increasing development activity in the past decade, patients are yet to see a commercialized smart shunt. Most smart shunt development focuses on concepts or on isolated technical features, but successful smart shunt designs will be a balance between technical feasibility, economic viability, and acceptable regulatory risk. Here, we present the status of this effort and a framework for understanding the challenges and opportunities that will guide introduction of smart shunts into patient care.
[Acute hepatic vascular complications].
Ochs, A
2011-07-01
Acute hepatic vascular complications are rare. Acute portal vein thrombosis (PVT) and the Budd-Chiari syndrome (BSC) are the leading causes. Coagulopathy and local factors are present in up to 80% of cases. Diagnosis is established by colour-coded Doppler sonography, contrast-enhanced computed tomography or magnetic resonance imaging. Patients with acute PVT present with abdominal pain and disturbed intestinal motility. In the absence of cirrhosis anticoagulation with heparin is established followed by oral anticoagulation. In severe cases, surgical thrombectomy or transjugular thrombolysis with stent shunt may be necessary. Acute or fulminant BCS may require emergency liver transplantation or a transjugular intrahepatic portosystemic stent shunt, if patients present with acute liver failure. Milder cases receive anticoagulation for thrombolysis of occluded hepatic veins. Sinusoidal obstruction syndrome (SOS) is diagnosed after total body irradiation or chemotherapy, the term SOS replacing the former veno-occlusive disease. The treatment of congenital vascular malformations, complications in the setting of OLTX as well as patients with hepatic involvement of hereditary hemorrhagic telangiectasia requires significant expertise in a multidisciplinary approach.
Caretta, Giorgio; Robba, Debora; Bonadei, Ivano; Teli, Melissa; Fontanella, Benedetta; Farina, Davide; Raddino, Riccardo; Cas, Livio Dei
2009-01-01
Paradoxical embolism is defined as a systemic arterial embolism requiring the passage of a venous thrombus into the arterial circulatory system through a right-to-left shunt. It is a relatively rare phenomenon, representing about 2% of all cases of arterial embolism. We report a case of a 79-years-old woman admitted to hospital because of dyspnea and lower left limb pain. CT scan revealed multiple thrombi to kidney, lower limb and superior mesenteric artery during acute pulmonary embolism. Echocardiogram documented a patent foramen ovale with a right-to-left shunt. The patient was treated with thrombolytic therapy and heparin with progressive improvement of symptoms and resolution of pulmonary embolism and peripheral thrombosis. Patent foramen ovale closure was not performed because a life-long anticoagulation therapy was necessary, a tunnel-type patent foramen ovale may increases difficulty in realizing device implantation and there are no clear evidence-based guidelines to date addressing treatment in presence of a patent foramen ovale. PMID:19918422
Fritsch, P; Grubauer, G; Hilty, N; Biedermann, H
1989-07-01
A hypervascularization syndrome following arterialization of the deep dorsal vein of the penis to amend venous erectile impotence is a rare cause of penile ulcers that has not previously been described in the dermatological literature. Arterialization is performed by installing a shunt from the inferior epigastric artery or a venous bypass from the femoral artery to the deep dorsal vein of the penis, resulting in a blockage of venous outflow and in retrograde inflow into the corpora cavernosa. Complications arise as a result of persistently elevated blood pressure in the deep venous system and the erectile tissue in 10-20% of cases and are most often linked to dilatation of the shunt: the consequences are enlargement and induration of the glans, hazard of phimosis and paraphimosis, pulsation of the penis, micturation difficulties and, ultimately, ulceration of the glans. Surgical reduction of the arterial inflow ("banding" of the shunt) is the only therapeutic procedure that reduces hypervascularization without compromising the newly gained erectile function.
Application of VSC-HVDC with Shunt Connected SMES for Compensation of Power Fluctuation
NASA Astrophysics Data System (ADS)
Linn, Zarchi; Kakigano, Hiroaki; Miura, Yushi; Ise, Toshifumi
This paper describes the application of VSC-HVDC (High Voltage DC Transmission using Voltage Source Converter) with shunt connected SMES (Superconducting Magnetic Energy Storage) for compensation of power fluctuation caused by fluctuating power source such as photovoltaics and wind turbines. The objectives of this proposed system is to smooth out fluctuating power in one terminal side of HVDC in order to avoid causing power system instability and frequency deviation by absorbing or providing power according to the system requirement while another terminal side power is fluctuated. The shunt connected SMES charges and discharges the energy to and from the dc side and it compensates required power of fluctuation to obtain constant power flow in one terminal side of VSC-HVDC system. This system configuration has ability for power system stabilization in the case of power fluctuation from natural energy source. PSCAD/EMTDC simulation is used to evaluate the performance of applied system configuration and control method.
Pseudotumor cerebri following traumatic brain injury in a 29-year-old man
Rahman, Mohammed Izad; Raveendran, Savitha; Kaliaperumal, Chandrasekaran; Marks, Charles
2012-01-01
We describe a case of pseudotumor cerebri in a young man developing 4 years post-traumatic brain injury (TBI). A 29-year-old man was admitted after sustaining a fall with headache, and no clinical deficits were noted on examination. CT brain demonstrated an extradural hematoma. This was successfully evacuated after his symptomatic worsening. Following this, he developed bone flap infection and had the infected bone flap removed. He developed chronic mild-to-moderate headache following these procedures, which failed to respond to medical treatment. Pseudotumor cerebri was diagnosed. A lumboperitoneal (LP) shunt, ventriculo-peritoneal (VP) shunt, and bitemporal craniectomy were performed as a part of management at different stages. Post-TBI patients may present with chronic headache and in such circumstances, a possibility of pseudotumor cerebri must be considered. Investigations should include neuroimaging in the form of MRI/MRV and fundoscopy to look for papilledema. Management in the form of CSF flow diversion techniques (VP and LP shunt) with medical management results in good clinical outcomes PMID:22690064
Hepatic focal nodular hyperplasia with congenital portosystemic shunt.
Cho, Yuki; Shimono, Taro; Morikawa, Hiroyasu; Shintaku, Haruo; Tokuhara, Daisuke
2014-12-01
Hepatic focal nodular hyperplasia (FNH) is a rare benign tumor in children. Vascular anomalies have been identified as pathological features of FNH, but the etiology remains unclear. We describe a rare case including the time course of formation of hepatic FNH in response to congenital portosystemic shunt (PSS). A 4-month-old girl was identified on newborn mass screening to have hypergalactosemia, but no inherited deficiencies in galactose-metabolizing enzymes were found. Ultrasonography and per-rectal portal scintigraphy showed intrahepatic PSS of the right lobe as a cause of the hypergalactosemia. At age 12 months, the patient had elevated hepatic enzymes and small hypoechoic hepatic lesions around the shunt. On abdominal contrast-enhanced ultrasonography spoke-wheel sign and central stellate scar were seen, which are typical features of hepatic FNH without biopsy. Congenital intrahepatic PSS should be evaluated on abdominal contrast-enhanced ultrasonography and observed over time because of its potential to develop into hepatic FNH. © 2014 Japan Pediatric Society.
[Whole-body vibration risk among operators in railway engines shunting ].
Abbate, A; Saffioti, G; Malara, G; Licordari, P; Carrello, S; De Pasquale, D; Giorgianni, C
2007-01-01
Purpose of the present note is to assess the risk from Whole-body vibration (WBV) in operators employed in the shunting of engines within the railway stations. The study has been conducted in the cockpits of the shunting engines used within the railway station of Villa S. Giovanni (RC). The measures have been taken through accelerometer IHVM 100 Larson-Davis, placed on the seat of each locomotives for a recording time of around 15 minutes. A standard measure has been effected besides, positioning the sensor on the floor of the same locomotives. The measurements indicate that the risk to these workers is negligible because in any case the value is exceeded action daily 0.5 m/s2, having recorded values range from 0.1 to 0.2 m / s2. In conclusion it holds him necessary, to the preventive goals, in respect to how much anticipated from the D.L.gs 187/05 the necessary technical, organizational and formative measures to the containment of the risk.
Laparoscopic umbilical hernia repair in a cirrhotic patient with a peritoneovenous shunt.
Umemura, Akira; Suto, Takayuki; Sasaki, Akira; Fujita, Tomohiro; Endo, Fumitaka; Wakabayashi, Go
2015-05-01
A 62-year-old Japanese woman who had developed massive cirrhotic ascites was referred to our hospital for a peritoneovenous shunt implant. However, CT examination revealed an umbilical hernia that had not been observed before the peritoneovenous shunt was implanted. We decided to perform laparoscopic umbilical hernia repair to keep carbon dioxide from flowing backward into the central circulatory system. We first clamped the catheter and set the upper limit of the pneumoperitoneum pressure to 6 mmHg. The central venous pressure was also measured simultaneously. Mesh was then applied over the hernia and fixed by the double-crown technique. Finally, 1000-mL physiological saline was infused into the abdominal cavity while the pneumoperitoneum was slowly released. In this case, we safely performed laparoscopic umbilical hernia repair while making some alterations, specifically catheter clamping, reducing pneumoperitoneum pressure, monitoring central venous pressure, and infusing physiological saline. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.
Bardy, G H; Talano, J V; Meyers, S; Lesch, M
1979-12-01
A case of traumatic tricuspid insufficiency leading to right atrial enlargement and to a patent foramen ovale with right to left shunting is presented. Six similar cases previously reported are reviewed. The time course of clinical deterioration was related to the type of tricuspid valve damage incurred. Papillary muscle rupture led to surgery within a year, whereas less severe chordal damage allowed a more benign course that lasted from 10 to 25 years from the time of injury to the time of surgery. Surgical repair of the incompetent tricuspid valve and closure of the atrial septal defect led to significant improvement. The diagnostic usefulness of radionuclide imaging and echocardiography is demonstrated in this case. A mechanism of right to left interatrial shunting in the presence of normal pulmonary arterial pressures is proposed; this invokes phasic increases in right atrial pressure from tricuspid insufficiency and streaming of blood from the inferior vena cava into the left atrium across a patent foramen ovale in a manner that resembles conditions in the fetal circulation.
Roth, Jonathan; Constantini, Shlomi; Kesler, Anat
2015-01-01
Idiopathic intracranial hypertension (IIH) may lead to visual impairment. Shunt surgery is indicated for refractory IIH-related symptoms that persist despite medical treatment, or those presenting with significant visual decline. Obesity is a risk factor for IIH; a reduction in weight has been shown to improve papilledema. Bariatric surgery (BS) has been suggested for treating IIH associated with morbid obesity. In this study, we describe a high rate of over-drainage (OD) seen in patients following shunts and BS. The study cohort includes 13 patients with IIH that underwent shunt surgery for treatment of the IIH-related symptoms. Six patients underwent BS in addition to the shunt surgery (but not concomitantly). Seven patients had only shunt surgeries with no BS. Data were collected retrospectively. BS effectively led to weight reduction (body mass index decreasing from 43 ± 4 to 28 ± 5). Patients undergoing BS had 1-6 (2.5 ± 1.9) shunt revisions for OD following BS, as opposed to 0-3 (1.4 ± 1.1) revisions prior to BS over similar time spans (statistically insignificant difference), and 0-6 (1.6 ± 2.5) revisions among the non-BS patients over a longer time span (statistically insignificant difference). Two patients in the BS group underwent shunt externalization and closure; however, they proved to be shunt-dependent. Patients with IIH that undergo shunt surgery and BS (not concomitantly) may suffer from OD symptoms, necessitating multiple shunt revisions, and valve upgrades. Despite BS being a valid primary treatment for some patients with IIH, among shunted patients, BS may not lead to resolution of IIH-related symptoms and patients may remain shunt-dependent.
Klinge, Petra; Marmarou, Anthony; Bergsneider, Marvin; Relkin, Norman; Black, Peter McL
2005-09-01
To develop guidelines for assessing shunt outcome in patients with idiopathic normal-pressure hydrocephalus (INPH). To date, the literature available on this topic has been marked by disparate definitions of clinical improvement, varying postoperative follow-up protocols and periods, and substantial differences in the postoperative management. Because specific criteria for defining clinical improvement are seldom reported, conclusions drawn about shunt outcome may be subjective. A MEDLINE search back to 1966 was undertaken using the query NPH, normal-pressure hydrocephalus, shunting, shunt treatment, shunt response, outcome, and clinical outcome. The criteria for selection were studies that included INPH from 1966 to the present in which the outcome of INPH was reported in patient groups of 20 or more. To date, there is no standard for outcome assessment of shunt treatment in INPH. The variable improvement rates reported are not only because of different criteria for selection of patients but also because of different postoperative assessment procedures and follow-up intervals. Studies that have established fixed protocols for follow-up have shown that short- and long-term periods after shunting are determined by many factors. Whereas short-term results were more likely to be influenced by shunt-associated risks, long-term results were independent of factors inherent to the shunt procedure and shunt complications, i.e., death and morbidity related to concomitant cerebrovascular and vascular diseases. Studies have shown that beyond 1 year after surgery, these factors definitely influence the clinical effect of shunting, making the 1-year postshunt period a potential determinant of the shunt outcome. Guidelines for outcome assessment were developed on the basis of the available evidence and consensus of expert opinion.
TIPS stent migration into the heart with 6-year follow-up.
Fehervari, Imre; Szonyi, Laszlo; Fazakas, Janos; Gerlei, Zsuzsa; Lazar, Istvan
2011-01-01
The transjugular intrahepatic portosystemic shunt (TIPS) is widely used for the treatment of portal hypertension in adults, but no studies have defined the best approach to treat portal hypertension in pediatric patients. Pediatric use of TIPS is rare even in large centers of adult practice. The migration of stents has also been reported as a complication in adults. There is no standard way to treat this type of complication, and it is not always clear whether immediate removal or watchful waiting is safer for the patient. We report the case of an 11-year-old patient who underwent urgent TIPS implantation due to variceal bleeding, after unsuccessful sclerotherapy. During the procedure, due to the deep impact of the stent, a second, telescopic, stent was inserted. The portal pressure decreased, no further bleeding occurred, and the patient was listed for transplantation. Three weeks later a routine chest X-ray discovered the migration of the second stent into the right ventricle. No interventional radiological removal or open heart surgery was available for the transplant waiting list patient. The patient underwent uneventful combined liver-kidney transplantation. During the 6-year follow-up period the child had no signs of hemodynamic instability, and his somatic and mental development were appropriate. To our knowledge this case is the first publication on a heart-impacted TIPS stent in a child. The watchful waiting was justified by uneventful combined liver-kidney transplantation and long-term follow-up. This case also underlines the need for best practice guidelines in pediatric portal hypertension.
Panagiotopoulos, V; Konstantinou, D; Kalogeropoulos, A; Maraziotis, T
2005-09-01
Although sporadic studies have described temporary external cerebrospinal fluid (CSF) lumbar drainage as a highly accurate test for predicting the outcome after ventricular shunting in normal pressure hydrocephalus (NPH) patients, a more recent study reports that the positive predictive value of external lumbar drainage (ELD) is high but the negative predictive value is deceptively low. Therefore, we conducted a prospective study in order to evaluate the predictive value of a continuous ELD, with CSF outflow controlled by medium pressure valve, in NPH patients. Twenty-seven patients with presumed NPH were admitted to our department and CSF drainage was carried out by a temporary (ELD) with CSF outflow controlled by a medium pressure valve for five days. All patients received a ventriculoperitoneal shunt using a medium pressure valve based upon preoperative clinical and radiographic criteria of NPH, regardless of ELD outcome. Clinical evaluation of gait disturbances, urinary incontinence and mental status, and radiological evaluation with brain CT was performed prior to and after ELD test, as well as three months after shunting. Twenty-two patients were finally shunted and included in this study. In a three-month follow-up, using a previously validated score system, overall improvement after permanent shunting correlated well to improvement after ELD test (Spearman's rho = 0.462, p = 0.03). When considering any degree of improvement as a positive response, ELD test yielded high positive predictive values for all individual parameters (gait disturbances 94%, 95% CI 71%-100%, urinary incontinence 100%, 95% CI 66%-100%, and mental status 100%, 95% CI 66%-100%) but negative predictive values were low (< 50%) except for cognitive impairment (85%, 95% CI 55%-98%). This study suggests that a positive ELD-valve system test should be considered a reliable criterion for preoperative selection of shunt-responsive NPH patients. In case of a negative ELD-valve system test, further investigation of the presumed NPH patients with additional tests should be performed.
Surgical management of bacterial meningitis.
Humphreys, R. P.
1975-01-01
A variety of associated lesions may require the neurosurgeon's assistance in the management of bacterial meningitis. As treatment of this infection of the central nervous system proceeds, the surgeon will have to decide about the concurrent or subsequent operative treatment of congenital dysraphic states, paraneural infections, compound fractures or penetrating wounds of thecranium or spine, or infected bypass shunts for cerebrospinal fluid (CSF). In patients with intractable meningitic infections the surgeon may have to insert a ventricular drainage-irrigation system to permit adequate perfusion of the CSF pathways with antibiotic. Hydrocephalus or subdural effusions complicating meningitis may bring the patient to the surgeon long after the infection has been cured. This paper examines these problems and outlines the current principles of management. Images FIG. 1 FIG. 2 PMID:1098760
Evaluation of Mismatch Losses due to Shunts in industrial Silicon Photovoltaic Modules
NASA Astrophysics Data System (ADS)
Somasundaran, P.; Shilpi, M.; Gupta, R.
2017-05-01
In order to achieve higher efficiencies in photovoltaic module technology, it is important to characterize the shunts and other defects which degrade the performance of cells and modules as well as decrease their efficiency. These shunts also affect the reliability of cells and modules. It is important to understand how much fill factor and power loss is caused by the presence of shunts in the module. Shunts not only reduce the module power output, but also affect the I-V characteristics of the cell and hence the characteristics of the shunted cells are different from those of the shunt-free cells connected in the module leading to the mismatch effect. This is an interesting effect which has been systematically investigated in the present work. Moreover, the flow of increased shunt current will give rise to increased temperature in the region of shunt, which will affect the cell and hence module performance. In the present study, the distributed diode model has been extended to the module level and applied to evaluate the electrical mismatch losses and thermal mismatch losses due to shunts in industrial Silicon PV modules.
Hillis, L D; Winniford, M D; Jackson, J A; Firth, B G
1985-01-01
Of the various techniques that are available to assess the presence and magnitude of intracardiac shunting, oximetry and indicator dilution are used most frequently. This study was performed to compare these methods in adult patients with pure left-to-right intracardiac shunting. In 27 patients [12 men, 15 women, aged 32 +/- 12 (mean +/- SD) years], shunt magnitude was assessed in close temporal proximity by both techniques. The oximetric percentage left-to-right shunt averaged 55 +/- 16%, whereas the indocyanine green dye percentage shunt was significantly less (36 +/- 14%, p less than 0.001). The oximetric percentage shunt exceeded the indocyanine green dye percentage shunt in 26 and did so by greater than 20% in 23 patients. Thus, there is a substantial difference in shunt magnitude between the oximetric and the indicator dilution techniques. In infants, indicator dilution yields results that are larger than those obtained with the oximetric method. Conversely, in adults, the indicator dilution technique gives results that are consistently smaller than those obtained with oximetry. As a result, the decision regarding therapy of an intracardiac shunt should be made with this in mind.
Outcome of infants shunted for post-haemorrhagic ventricular dilatation.
Hislop, J E; Dubowitz, L M; Kaiser, A M; Singh, M P; Whitelaw, A G
1988-08-01
Between April 1980 and March 1986, 19 infants underwent cerebrospinal fluid (CSF) shunting procedures for post-haemorrhagic ventricular dilatation at the Hammersmith Hospital, London. A total of 58 shunt-related procedures have been performed on these children. The major perioperative complication was seizure activity (eight children). Postoperative complications included infection (12 shunts) and blockage (29 shunts). Prophylactic antibiotics failed to prevent shunt infection. The likelihood of the first shunt failing was significantly reduced by greater weight of the infant and lower CSF protein at surgery. Long-term outcome was poor: three have died and another four are quadriplegic with severe mental retardation. Only four children are developmentally normal. These outcomes cannot be related to the shunt surgery or its complications, but correlate best with pre-operative parenchymal brain-lesions, as shown on ultrasound scans.
Passively Shunted Piezoelectric Damping of Centrifugally-Loaded Plates
NASA Technical Reports Server (NTRS)
Duffy, Kirsten P.; Provenza, Andrew J.; Trudell, Jeffrey J.; Min, James B.
2009-01-01
Researchers at NASA Glenn Research Center have been investigating shunted piezoelectric circuits as potential damping treatments for turbomachinery rotor blades. This effort seeks to determine the effects of centrifugal loading on passively-shunted piezoelectric - damped plates. Passive shunt circuit parameters are optimized for the plate's third bending mode. Tests are performed both non-spinning and in the Dynamic Spin Facility to verify the analysis, and to determine the effectiveness of the damping under centrifugal loading. Results show that a resistive shunt circuit will reduce resonant vibration for this configuration. However, a tuned shunt circuit will be required to achieve the desired damping level. The analysis and testing address several issues with passive shunt circuit implementation in a rotating system, including piezoelectric material integrity under centrifugal loading, shunt circuit implementation, and tip mode damping.
A cranial nail for fetal shunting.
Saunders, R L; Simmons, G M; Edwards, W H; Crow, H C
1985-01-01
A small number of human fetal hydrocephalics have been treated by ventriculoamniotic shunts of silastic tubing. The Colorado device appears to be the one most commonly used. The original experimental device tested on a primate model resembled a hollow shingle nail. This was designed by Michedja and Hodgen, contained a spring valve, measured approximately 32 X 4 mm and was placed by hysterotomy. An attractive feature of this design was its fixation by impaction in the skull, preventing displacement by fetal activity, a reported disadvantage with the silastic devices. To our knowledge, no one has used this nail-like design and tailored it to transuterine percutaneous placement in a human case.
Novel Surgical Technique for Coronary Fistulas With Proximal Origin.
Uchida, Tetsuro; Hamasaki, Azumi; Kuroda, Yoshinori; Ohba, Eiichi; Yamashita, Atsushi; Sadahiro, Mitsuaki
2017-09-01
Postoperative residual shunting is a significant concern in patients with coronary arteriovenous fistulas, especially in fistulas originating from the proximal left coronary artery, because of the limited surgical field. We report a case of fistulas originating from the proximal coronary artery in a 63-year-old woman in whom the ascending aorta and pulmonary artery were transected to obtain good surgical exposure. After complete transection of both great arteries, fistulas arising from the left main trunk were ligated externally, and their intracardiac openings were closed internally. Postoperative examination revealed no residual shunt flow. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Cooray, S; Zhang, H; Breen, R; Carr-White, G; Howard, R; Cuadrado, M; D'Cruz, D; Sanna, G
2018-04-01
Central nervous system (CNS) tuberculosis (TB) is a rare but catastrophic event in patients with systemic lupus erythematosus (SLE). Here we report a case of cerebral TB in a patient with lupus myocarditis and nephritis, following cyclophosphamide immunosuppression. To our knowledge this is the first reported case of cerebral TB in SLE in a non-endemic country. A 31-year-old female with SLE and a history of regular travel to Kenya presented to our centre with clinical features of acute heart failure. She was diagnosed with severe lupus myocarditis, and a renal biopsy also confirmed lupus nephritis. Prior to admission, she had also had a cough, fever and weight loss and was under investigation for suspected TB infection. She was treated with ivabradine, beta-blockers and diuretics together with methylprednisolone and cyclophosphamide immunosuppression. Subsequent sputum cultures confirmed TB and she was commenced on triple therapy. Despite this, she developed confusion, dizziness, blurred vision and fluctuating consciousness. Magnetic resonance imaging (MRI) and lumbar puncture revealed CNS TB infection resulting in meningitis. This was later complicated by obstructive hydrocephalus due to TB abscesses. A ventriculoperitoneal (VP) shunt was inserted and TB medications were given intravenously (IV) with dexamethasone. Following a prolonged hospital admission, the patient eventually recovered and rituximab treatment was used to control her SLE. TB infection has been associated with SLE flares. It is likely in this case that TB exacerbated a lupus flare and subsequent immunosuppression resulted in mycobacterial dissemination to the CNS. Systemic and CNS features of TB and SLE are difficult to distinguish and their contemporaneous management represents a diagnostic and therapeutic challenge.
Concealed Accessory Pathways with a Single Ventricular and Two Discrete Atrial Insertion Sites.
Kipp, Ryan T; Abu Sham'a, Raed; Hiroyuki, Ito; Han, Frederick T; Refaat, Marwan; Hsu, Jonathan C; Field, Michael E; Kopp, Douglas E; Marcus, Gregory M; Scheinman, Melvin M; Hoffmayer, Kurt S
2017-03-01
Atrioventricular reciprocating tachycardia (AVRT) utilizing a concealed accessory pathway is common. It is well appreciated that some patients may have multiple accessory pathways with separate atrial and ventricular insertion sites. We present three cases of AVRT utilizing concealed pathways with evidence that each utilizing a single ventricular insertion and two discrete atrial insertion sites. In case one, two discrete atrial insertion sites were mapped in two separate procedures, and only during the second ablation was the Kent potential identified. Ablation of the Kent potential at this site remote from the two atrial insertion sites resulted in the termination of the retrograde conduction in both pathways. Case two presented with supraventricular tachycardia (SVT) with alternating eccentric atrial activation patterns without alteration in the tachycardia cycle length. The two distinct atrial insertion sites during orthodromic AVRT and ventricular pacing were targeted and each of the two atrial insertion sites were successfully mapped and ablated. In case three, retrograde decremental conduction utilizing both atrial insertion sites was identified prior to ablation. After mapping and ablation of the first discrete atrial insertion site, tachycardia persisted utilizing the second atrial insertion site. Only after ablation of the second atrial insertion site was SVT noninducible, and VA conduction was no longer present. Concealed retrograde accessory pathways with discrete atrial insertion sites may have a common ventricular insertion site. Identification and ablation of the ventricular insertion site or the separate discrete atrial insertion sites result in successful treatment. © 2017 Wiley Periodicals, Inc.
What is the risk of infecting a cerebrospinal fluid-diverting shunt with percutaneous tapping?
Spiegelman, Lindsey; Asija, Richa; Da Silva, Stephanie L; Krieger, Mark D; McComb, J Gordon
2014-10-01
Most CSF-diverting shunt systems have an access port that can be percutaneously tapped. Tapping the shunt can yield valuable information as to its function and whether an infection is present. The fear of causing a shunt infection by tapping may limit the physician's willingness to do so. The authors of this study investigate the risk of infecting a shunt secondary to percutaneous tapping. Following institutional review board approval, CSF specimens obtained from tapping an indwelling CSF-diverting shunt during the 2011 and 2012 calendar years were identified and matched with clinical information. A culture-positive CSF sample was defined as an infection. If results were equivocal, such as a broth-only-positive culture, a repeat CSF specimen was examined. The CSF was obtained by tapping the shunt access port with a 25-gauge butterfly needle after prepping the unshaven skin with chlorhexidine. During the study period, 266 children underwent 542 shunt taps. With 541 taps, no clinical evidence of a subsequent shunt infection was found. One child's CSF went from sterile to infected 11 days later; however, this patient had redness along the shunt tract at the time of the initial sterile tap. The risk of infection from tapping a shunt is remote if the procedure is done correctly.
[Congenital portosystemic shunt. The Abernethy malformation].
Avila, L F; Luis, A L; Encinas, J L; Hernández, F; Olivares, P; Fernández Cuadrado, J; Hierro, L; Jara, P; López Santamaría, M; Tovar, J A
2006-10-01
Congenital portosystemic shunt (CEPS) is a rare condition that was first reported by John Abernethy in 1793. Two types of CEPS are described: type I (side to end anastomosis) or congenital absence of the portal vein, and type II (side to side anastomosis) with portal vein supply partially conserved. Type I CEPS is usually seen in girls and associates multiple malformations as polysplenia, malrotation, and cardiac anomalies. Type II is even rarer with no sex preference and no malformations associated. Hepatic encephalopathy is a common complication of both types in adulthood. Liver transplantation is the only effective treatment for symptomatic type I CEPS. A therapeutic approach for type II could be surgical closure of the shunt. To analyse our experience in diagnosis and management of portosystemic shunts. We report 4 cases of CEPS (3 type I and 1 type II) diagnosed between January-1997 and March-2005 in our department. We present 4 patients with ages at diagnosis ranging from 0 to 28 months, 3 type I CEPS (2 boys and 1 girl) and 1 boy type II. The type I girl was prenatally diagnosed at 12 weeks of gestation. Initial clinical signs in type 1 boys were splenomegaly and hypersplenism, both with normal pondo-statural growth. No polysplenia or cardiac anomalies were assessed. One of them presented mild developmental delay, dismorphic features and facial telangiectasias. He had normal coagulation tests with chronic hepatic dysfunction (high transaminases) and regenerative nodular lesions were seen by imaging techniques. The other type I patient had hypoprothrombinemia, tendency to capillary bleeding (haematomas and epistaxis) with preserved liver function. Both patients have developed mild portal hypertension and present steatosis signs at liver biopsy. The type I girl presents a 21 trisomy and associates a cardiac anomaly (interauricular communication). Her hepatic function test are normal but liver calcifications can be seen by ultrasound. Type II child associates hypospadias but he has no clinical sigh or symptom related to the shunt. In our three cases diagnosis was suggested by conventional and Doppler ultrasound and confirmed by angio-resonance imaging. All our patients are included in a meticulous clinical and radiological follow-up with no need of surgical treatment for the shunt until now. Although diagnosis of these malformations could be casual we have to think about CEPS in children presenting unspecific liver disease. Magnetic angio-resonance imaging is actually the best diagnosis methods for CEPS. These patients have a high risk for developing hepatic encephalopathy and portal hypertension, so a careful follow-up is required although surgery is not usually needed until adulthood.
Shunting for normal pressure hydrocephalus (NPH).
Esmonde, T; Cooke, S
2002-01-01
Since the condition was first described in 1965, the syndrome of normal pressure hydrocephalus (NPH) has conventionally been managed by placement of a cerebrospinal fluid (CSF) shunt. To determine the effectiveness of shunting procedures in promoting stability or improvement in the neurological symptoms and signs of NPH. The trials were identified from a search of the Specialized Register of the Cochrane Dementia and Cognitive Improvement Group on 26 June 2001 using the terms 'shunt*' and 'normal pressure hydrocephalus'. Studies included for analysis were those involving the placement of a CSF shunt for the treatment of NPH as part of a randomized controlled trial. No data matching the selection criteria were found. No randomized controlled trials of shunt placement versus no shunt were found. There is no evidence to indicate whether placement of a shunt is effective in the management of NPH.
Harvey, Steven P.; Moseley, John; Norman, Andrew; ...
2018-02-27
We investigated the potential-induced degradation (PID) shunting mechanism in multicrystalline-silicon photovoltaic modules by using a multiscale, multitechnique characterization approach. Both field-stressed modules and laboratory-stressed mini modules were studied. We used photoluminescence, electroluminescence, and dark lock-in thermography imaging to identify degraded areas at the module scale. Small samples were then removed from degraded areas, laser marked, and imaged by scanning electron microscopy. We used simultaneous electron-beam induced current imaging and focused ion beam milling to mark around PID shunts for chemical analysis by time-of-flight secondary-ion mass spectrometry or to isolate individual shunt defects for transmission electron microscopy and atom-probe tomography analysis.more » By spanning a range of 10 orders of magnitude in size, this approach enabled us to investigate the root-cause mechanisms for PID shunting. We observed a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiNX/Si interface and is consistently observed at a concentration of 0.1% to 2% in shunted areas. Analysis of samples subjected to PID recovery, either activated by electron beam or thermal effects only, reveals that recovery of isolated shunts correlates with diffusion of sodium out of the structural defects to the silicon surface. We observed the role of oxygen and chlorine in PID shunting and found that those species - although sometimes present in structural defects where PID shunting was observed - do not play a consistent role in PID shunting.« less
New and improved ways to treat hydrocephalus: Pursuit of a smart shunt
Lutz, Barry R.; Venkataraman, Pranav; Browd, Samuel R.
2013-01-01
The most common treatment for hydrocephalus is placement of a cerebrospinal fluid shunt to supplement or replace lost drainage capacity. Shunts are life-saving devices but are notorious for high failure rates, difficulty of diagnosing failure, and limited control options. Shunt designs have changed little since their introduction in 1950s, and the few changes introduced have had little to no impact on these long-standing problems. For decades, the community has envisioned a “smart shunt” that could provide advanced control, diagnostics, and communication based on implanted sensors, feedback control, and telemetry. The most emphasized contribution of smart shunts is the potential for advanced control algorithms, such as weaning from shunt dependency and personalized control. With sensor-based control comes the opportunity to provide data to the physician on patient condition and shunt function, perhaps even by a smart phone. An often ignored but highly valuable contribution would be designs that correct the high failure rates of existing shunts. Despite the long history and increasing development activity in the past decade, patients are yet to see a commercialized smart shunt. Most smart shunt development focuses on concepts or on isolated technical features, but successful smart shunt designs will be a balance between technical feasibility, economic viability, and acceptable regulatory risk. Here, we present the status of this effort and a framework for understanding the challenges and opportunities that will guide introduction of smart shunts into patient care. PMID:23653889
Hirai, Akiko; Hirose, Yoshifumi; Gamoh, Masahiro; Satoh, Minako
2005-10-01
We report successful management of tracheobronchial stent insertion under general anesthesia. In thirty-two cases, tracheobronchial stent insertion was performed under general anesthesia. The technique for airway management was chosen depending on the type of stent or the constriction level of the airway portion. We employed tracheostomy in order to avoid repeated intubations during the insertion of Dumon or Dynamic stent. In case of severe airway stenosis, laser resection or balloon dilatation was performed before stent insertion. We had 32 successful cases in 36 trials. Four trials failed due to insufficient expansion in one, mismatches of stent angle in one and pneumomediastinum in one. There was no exacerbation of respiratory condition in failed cases. There was no case who needed percutaneous cardiopulmonary support system. We managed tracheobronchial stent insertion under general anesthesia. Both the airway expansion by laser resection or balloon dilatation before stent insertion and also the insertion of Dumon or Dynamic stent through a tracheostomy were helpful strategies. These techniques facilitated more definitive airway maintenance and stable anesthetic management.
Acosta, Eduardo Mariano Albers; Reyes, Alfonsi Friera; Menéndez, Ricardo Brime
2015-01-01
The ectopic varices in patients with portal hypertension are those that occur at any level of the gastrointestinal (GI) tract, regardless of the varices that occur at the esophageal level. These ectopic varices account for 2–5% of the causes of GI bleeding varices. The risk of bleeding is quadrupled compared to the esophagogastric area, with a mortality of up to 40%. The transjugular intrahepatic portosystemic shunt, should be considered in cases secondary to recurrent bleeding varices. We present a case report of an urological emergency of bleeding in a urinary diversion secondary to ectopic varices successfully treated through the placement of transjugular intrahepatic portosystemic shunt. The condition described here is rare, but important, as it can be a life-threatening complication of portal hypertension. This kind of complication should be known by urologic surgeons managing patients with urinary diversions. PMID:26834901
Hepatic vascular shunts: embryology and imaging appearances
Bhargava, P; Vaidya, S; Kolokythas, O; Katz, D S; Dighe, M
2011-01-01
The purpose of this pictorial review is to understand the embryological basis of the development of congenital hepatic vascular shunts and to review the multimodality imaging appearances of congenital and acquired hepatic vascular shunts. Hepatic vascular shunts are commonly seen in imaging. Familiarity with their characteristic appearances is important in order to accurately characterise these shunts and diagnose the underlying disorders. PMID:22101582
Treatment of refractory chylothorax with externalized pleuroperitoneal shunts in children.
Wolff, A B; Silen, M L; Kokoska, E R; Rodgers, B M
1999-09-01
Traditional therapy for refractory chylothorax in the pediatric population has included pleurodesis and thoracic duct ligation. These procedures are associated with high morbidity and questionable success rates. We retrospectively reviewed our experience with 15 patients who underwent treatment for chylous effusions using pleuroperitoneal shunts with exteriorized pump chambers. Mean patient age at time of shunt placement was 2.1 (0.1 to 11.5) years and the most common indication (7 of 15) was refractory chylothorax following surgical correction of congenital heart disease. Mean chylothorax duration before shunt placement was 76 (5 to 810) days and shunts were in place for an average of 104 (12 to 365) days. A total of 19 chylous effusions (pleural or pericardial) were treated with shunts. Nine of 11 right-sided chylothoraces, 5 of 6 left-sided chylothoraces, and 2 of 2 chylopericardia resolved with shunt therapy (84% total). Pleuroperitoneal shunting failed to clear the effusion in 3 children. There were six episodes of shunt malfunction that were repaired and two episodes of infection. Inguinal or umbilical hernia developed in 4 patients. Externalized pleuroperitoneal shunting is a safe, effective, and minimally invasive treatment for children with refractory chylous effusions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Wire, shunt. 236.838 Section 236.838 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Wire, shunt. A wire forming part of a shunt circuit. ...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Wire, shunt. 236.838 Section 236.838 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Wire, shunt. A wire forming part of a shunt circuit. ...
Xiao, Bo; Roth, Jonathan; Udayakumaran, Suhas; Beni-Adani, Liana; Constantini, Shlomi
2011-05-01
Endoscopic third ventriculostomy (ETV) has become standard for obstructive hydrocephalus. Even a successful ETV can obstruct, leading to recurrence of symptoms and even death. A possible solution to this problem is leaving an Ommaya reservoir (OR) following the ETV. OR can be tapped in an emergency and for diagnostic purposes. No specific complications have been attributed to OR in this setting. We present our experience with OR in children undergoing ETV for hydrocephalus. A retrospective study was conducted in hydrocephalic children that underwent ETV with OR insertion over 13 years (1997-2010) from a single institution. Data were collected from charts and follow-ups. Twelve patients (from 200 patients who had an ETV) underwent placement of OR with ETV. OR was reserved for a subgroup of patients in whom we anticipated complications-in children that presented with acute hydrocephalus and were in deteriorating condition, for pathologies believed to have a low predicted ETV success rate, or when the surgeon felt that the ETV procedure was suboptimal. OR was tapped in eight patients. Complications occurred in four patients: two cases of subdural effusion, one case of chronic subdural hematoma, and one CSF leak. Four ORs were removed due to complications, and four were converted to shunts. OR should be considered in selected patients undergoing ETV. Despite its obvious advantages, OR may be associated with a relatively high risk of extraaxial fluid collections. This association requires further investigation.
Ventriculosubgaleal shunts for posthemorrhagic hydrocephalus in premature infants.
Willis, Brian K; Kumar, Cherukuri Ravi; Wylen, Esther L; Nanda, Anil
2005-01-01
The early management of posthemorrhagic hydrocephalus in premature infants is challenging and controversial. These infants need a temporary cerebrospinal fluid (CSF) diversion procedure until they gain adequate weight, and the blood and protein levels in CSF are reasonably low before permanent shunt can be placed. Various options are available with their associated advantages and disadvantages. Ventriculosubgaleal shunts have been recommended as a more physiologic and less invasive means of achieving this goal. We have performed this procedure in 6 premature infants to evaluate their effectiveness and complications. Six consecutive premature infants with posthemorrhagic hydrocephalus underwent placement of ventriculosubgaleal shunts over a 1-year period of time. We reviewed their clinical and imaging progress to assess the ability of the shunt to control hydrocephalus and the complication rates. In all 6 patients, the ventriculosubgaleal shunt controlled the progression of hydrocephalus as assessed by clinical and imaging parameters. A permanent shunt was avoided in 1 patient (16.6%). However, 4 patients developed shunt infections, 1 involving the ventriculosubgaleal shunt itself, and 3 immediately after conversion to ventriculoperitoneal shunt. The total infection rate of the series was 66.6%. All infections were caused by staphylococcus species. There was only a 1% shunt infection rate in our institution for all nonventriculosubgaleal shunts during the same period of time. Placement of ventriculosubgaleal shunts for interim CSF diversion in neonates with posthemorrhagic hydrocephalus is effective as a temporary method of CSF diversion. However, our experience has shown that it is associated with a unacceptably high CSF infection rate. A potential cause for infection is CSF stasis just beneath the extremely thin skin of the premature infants, promoting colonization by skin flora. CSF sampling before conversion to a permanent shunt and replacement of the proximal hardware, which has been in situ for a prolonged period, may decrease the infection rates. At present, the procedure is no longer performed at our institution.
Nakajima, Madoka; Miyajima, Masakazu; Ogino, Ikuko; Akiba, Chihiro; Kawamura, Kaito; Kurosawa, Michiko; Kuriyama, Nagato; Watanabe, Yoshiyuki; Fukushima, Wakaba; Mori, Etsuro; Kato, Takeo; Sugano, Hidenori; Karagiozov, Kostadin; Arai, Hajime
2018-01-01
Background and Purpose: This study aimed to investigate the efficacy of cerebrospinal fluid shunt intervention for idiopathic normal pressure hydrocephalus (iNPH) using data from a nationwide epidemiological survey in Japan. Methods: We conducted a cross-sectional study using data from a nationwide epidemiological survey performed in Japan. Propensity score matching was used to select 874 patients from 1,423 patients aged ≥60 years, who were diagnosed with iNPH based on clinical guidelines following a hospital visit in 2012. Patients who experienced an improvement of at least 1 modified Rankin Scale (mRS) grade after the intervention were classified as "improved," while the remaining patients were classified as "non-improved." In the shunt intervention ( n = 437) and non-shunt intervention ( n = 437) groups, the differences in mRS grade improvement were analyzed using the Mann-Whitney U -test. Finally, we examined subjects in the shunt intervention group ( n = 974) to compare the outcomes and complications of ventriculoperitoneal (VP) shunt (n = 417) with lumboperitoneal (LP) shunt ( n = 540). Results: We examined subjects with iNPH to compare the non-shunt intervention group to the shunt intervention group following adjustment for age and mRS grade at baseline by propensity score matching (0.31-0.901). The mRS grade (mean [SD]) was found to improve with non-shunt intervention (2.46 [0.88]) and shunt intervention (1.93 [0.93]) ( p < 0.001) in iNPH patients. The mRS outcome score and complications comparison between the VP and LP shunt groups did not show significant difference. Conclusions: In this study, analysis of the efficacy of shunts for possible iNPH conducted in Japan indicated a significant improvement in the mRS grade between baseline and outcome within 1 year, regardless of the surgical technique, and shunt intervention was found to be effective.
Intracardiac Shunting and Stroke in Children: A Systematic Review
Dowling, Michael M.; Ikemba, Catherine M.
2017-01-01
In adults, patent foramen ovale or other potential intracardiac shunts are established risk factors for stroke via paradoxical embolization. Stroke is less common in children and risk factors differ. The authors examined the literature on intracardiac shunting and stroke in children, identifying the methods employed, the prevalence of detectible intracardiac shunts, associated conditions, and treatments. PubMed searches with keywords related to intracardiac shunting and stroke in children identified articles of interest. Additional articles were identified via citations in these articles or in reviews. The authors found that studies of intracardiac shunting in children with stroke are limited. No controlled studies were identified. Detection methods vary and the prevalence of echocardiographically detectible intracardiac shunting appears lower than reported in adults and autopsy studies. Defining the role of intracardiac shunting in pediatric stroke will require controlled studies with unified detection methods in populations stratified by additional risk factors for paradoxical embolization. Optimal treatment is unclear. PMID:21212453
Hisaba, Wagner Jou; Cavalheiro, Sérgio; Almodim, Carlos Gilberto; Borges, Carolina Peixoto; de Faria, Tereza Cristina Carbonari; Araujo Júnior, Edward; Nardozza, Luciano Marcondes Machado; Moron, Antonio Fernandes
2012-03-01
Present the outcomes of six cases submitted to intrauterine myelomeningocele (MMC) repair. Descriptive observational study of six children submitted to antenatal surgical repair of MMC between 26 and 27 weeks gestation. All deliveries were through cesarean section. The following neonatal variables were assessed: gestational age at delivery, birth weight, Apgar scores, need for intubation, duration of hospital stay and need for postnatal shunt procedures. After 3.5 years, the children were evaluated using the Columbia Mental Maturity Scale or Denver II tests and the Hoffer Ambulation Scale. All deliveries were preterm at a mean gestational age of 32 + 4 weeks and mean birth weight was 1,942 g. Two infants had Apgar scores <7 at 1 min and 1 at 5 min. Ventricular-peritoneal shunts were placed in two cases. All six children are alive: five have normal cognitive development and one has a neuropsychomotor developmental delay. Two children had normal leg movements, a sacral functional level and are community ambulators. Three children had upper lumbar anatomical level lesions and one had a lower thoracic level lesion at the time of fetal surgery. One child, with an L1-L2 anatomical level lesion, in noambulatory and fully dependent on a wheelchair for mobility. Antenatal surgical repair of MMC reduced the need for postnatal shunt placements. Despite preterm delivery, the cognitive development of most children at 3.5 years was normal. Antenatal surgery seemed to improve lower limb motor function in these cases.
Martino, Rodrigo B; Júnior, Eserval Rocha; Manuel, Valdano; Rocha-Santos, Vinicius; D'Albuquerque, Luis Augusto C; Andraus, Wellington
2017-10-11
BACKGROUND Adequate portal venous flow is required for successful liver transplantation. Reduced venous flow and blood flow 'steal' by collateral vessels are a concern, and when there is a prominent splenorenal shunt present, ligation of the left renal vein has been recommended to improve portal venous blood flow. CASE REPORT A 51-year-old man who had undergone right nephrectomy in childhood required liver transplantation for liver cirrhosis and hepatocellular carcinoma due to hepatitis C virus (HCV) infection. The patient had no other comorbidity and no history of hepatorenal syndrome. At transplantation surgery, portal venous flow was poor and did not improve with ligation of shunt veins, but ligation of the left renal vein improved portal venous flow. On the first and fifth postoperative days, the patient was treated with basiliximab, a chimeric monoclonal antibody to the IL-2 receptor, and methylprednisolone. The calcineurin inhibitor, tacrolimus, was introduced on the fifth postoperative day. On the sixteenth postoperative day, renal color Doppler ultrasound showed normal left renal parenchyma; hepatic Doppler ultrasound showed good portal vein flow and preserved hepatic parenchyma in the liver transplant. CONCLUSIONS This case report has shown that in a patient with a single left kidney, left renal vein ligation is feasible and safe in a patient with no other risk factors for renal impairment following liver transplantation. Modification of postoperative immunosuppression to avoid calcineurin inhibitors in the very early postoperative phase may be important in promoting good recovery of renal function and to avoid the need for postoperative renal dialysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amouyal, Gregory, E-mail: gregamouyal@hotmail.com; Chague, Pierre, E-mail: pierre.chague@gmail.com; Pellerin, Olivier, E-mail: olivier.pellerin@aphp.fr
IntroductionDuring PAE, preembolization angiography of the prostatic artery can show large extra-prostatic shunts, at high risk, if embolized, of rectal or penile necrosis. We report our experience with 11 consecutive patients who underwent protective embolization of large extra-prostatic shunts before successful PAE.Materials and MethodsWe treated 11 consecutive male patients (mean age 67 years), part of a series of 55 consecutive male patients referred for PAE to treat LUTS due to BPH, between December 2013 and January 2015. The procedure involved the exclusion of an extra-prostatic shunt originating from the PA, prior to complete bilateral PAE. We compared the safety and efficacymore » of the 11 shunt exclusions followed by embolization of the PA to the other 44 basic PAE. Clinical success was defined as a decrease of 25 % or eight points of IPSS, QoL <3 or a one-point decrease, and a Qmax improvement of 25 % or 2.5 mL/s.ResultsWe had a 100 % rate of occlusion of the anastomosis. Bilateral embolization of the PA was performed in all patients with no additional time of procedure (p = 0.18), but a significant increase of dose area product (p = 0.03). Distal (PErFecTED) embolization was possible in 64 %. There was no worsening of erectile dysfunction, no rectal or penile necrosis, no immediate or late other clinical complications. Clinical success was 91 % (mean follow-up: 3.5 months), compared to 78 % for the entire PAE group.ConclusionPAE using the protection technique in case of large extra-prostatic shunts is as safe and effective as basic procedures and does not induce any additional time of procedure.« less
Pavlinec, Jonathan G; Hakky, Tariq S; Yang, Christopher; Massis, Kamal; Munarriz, Ricardo; Carrion, Rafael E
2014-09-01
Penile revascularization is a surgical treatment option for erectile dysfunction (ED) in healthy individuals due to a focal arterial occlusion in the absence of generalized vascular disease. Most described failures have been attributed to graft stenosis or disruption of the anastomosis. We report a novel phenomenon called Penile Artery Shunt Syndrome that contributed to persistent ED in a patient after penile microvascular arterial bypass surgery. A 26-year-old man presented for evaluation of long-standing ED, which was attributed to trauma sustained 12 years earlier. He had difficulty obtaining and maintaining erections despite oral pharmacotherapy. Clinical data related to the case were studied, analyzed, and reviewed with urologic and radiologic specialists at multiple centers that collaborated in the care of this patient. Penile duplex ultrasound peak systolic velocities and five-item International Index for Erectile Function questionnaire scores were the main outcome measures. Initial diagnostic workup of the patient confirmed severe insufficiency of the left cavernosal artery, with no evidence of venous leak. The patient underwent penile microvascular arterial bypass surgery with anastomosis of the left inferior epigastric artery to the left dorsal penile artery. The patient had persistence of severe ED despite patent anastomosis by penile duplex ultrasound. Subsequent arteriography revealed an arterial shunt due to an aberrant obturator artery arising from the donor inferior epigastric artery. The patient underwent embolization of the aberrant obturator artery, with resolution of the shunt and marked improvement in erectile function. The presence of an aberrant obturator artery arising from the inferior epigastric artery may predispose to persistent ED after revascularization due to the creation of a shunt phenomenon. Pelvic arteriography may be useful in identifying anomalous anatomic considerations prior to penile revascularization and to evaluate patients with persistent postoperative ED. © 2014 International Society for Sexual Medicine.
Endoscopic Third Ventriculostomy Instead of Shunt Revision in Children Younger Than 3 Years of Age.
Zhao, Rui; Shi, Wei; Yang, Haowei; Li, Hao
2016-04-01
Endoscopic third ventriculostomy (ETV) is a valuable option in the treatment of shunt failure, but no clinical data exist for young children. The aim of this study was to elucidate the role of ETV in patients younger than 3 years of age with shunt malfunction. A cohort of 37 patients younger than 3 years of age with shunt malfunction underwent ETV instead of shunt revision. Patients' preoperative condition and medical history were studied to determine the impact of a number of variables on outcome. The Fisher exact test was used to assess differences among groups. Median age at ETV was 21.6 months (8-36 months). Diagnosis was obstructive hydrocephalus in 24 patients and communicating hydrocephalus in 13. Median age at initial shunt placement was 3.2 months (10 days to 30 months). The etiology of shunt malfunction was obstruction (n = 27) or infection (n = 10). Overall ETV failure rate was 40.5% (15/37). Patients whose age at initial shunt placement was <6 months and/or who had a preterm birth history had higher relative rates of ETV failure. Other variables, including type of hydrocephalus, interval between initial shunt placement and ETV, history of intraventricular bleeding and/or infection, and etiology of shunt malfunction, did not significantly affect the final outcome. Patients younger than 3 years with obstructive or communicating hydrocephalus may benefit from ETV in the event of shunt malfunction and have about a 60% probability of becoming shunt free. Copyright © 2016 Elsevier Inc. All rights reserved.
Testuz, Ariane; Roffi, Marco; Bonvini, Robert Francis
2013-03-01
This case aims to describe the hemodynamic effects of intra-aortic balloon pump (IABP) in patients with ventricular septal defect (VSD) complicating myocardial infarction (MI). A 79-year-old man with no previous cardiovascular history presented to the emergency department with subacute inferior myocardial infarction associated with mild signs of systemic hypoperfusion. A transthoracic echocardiography revealed a large akinesia of the left ventricular inferior wall with preserved global left ventricular ejection fraction, as well as a large VSD in the midinferior portion of the interventricular septum. Coronary angiography showed an occlusion of the mid portion of a dominant circumflex coronary artery. The invasive hemodynamic evaluation showed a sizable left-to-right shunt (Q(p)/Q(s) = 3.1). Activation of the IABP led to an immediate reduction of the shunt (Q(p)/Q(s) = 2.4 = 22% reduction), an increase in systemic cardiac output (from 2.1 L/min to 2.4 L/min = +12%) and a decrease in the systemic vascular resistances (from 2240 to 1920 dyne-sec/cm(5) = 15% reduction). In patients with post-MI VSD, placement of IABP leads to an immediate reduction in left-to-right shunt and as a consequence to an increase in systemic cardiac output, which may allow hemodynamic stabilization of the patient prior to surgical VSD closure. Copyright © 2012 Wiley Periodicals, Inc.
Angiolymphoid Hyperplasia with Eosinophilia: A Case Report
Esteves, Paola; Barbalho, Marcella; Lima, Tiago; Quintella, Leonardo; Niemeyer-Corbellini, João Paulo; Ramos-e-Silva, Marcia
2015-01-01
Angiolymphoid hyperplasia with eosinophilia is a rare disease considered as being a vascular malformation resulting from a subjacent arteriovenous shunt. It affects mostly the head of women between 20 and 40 years old and may present spontaneous involution. PMID:26120306
Fan, Tao; Zhao, XinGang; Zhao, HaiJun; Liang, Cong; Wang, YinQian; Gai, QiFei; Zhang, Fangyi
2015-10-01
It is well established that syringomyelia can cause neurological symptoms and deficit by accumulation of fluid within syrinx cavities that lead to internal compression within the spinal cord. When other intervention treating the underlying etiology failed to yield any improvement, the next option would be a procedure to divert the fluid from the syrinx cavity, such as syringo-subarachnoid, syringo-peritoneal or syringo-pleural shunting. The indications and long term efficacy of these direct shunting procedures are still questionable and controversial. To investigate the clinical indication, outcome and complication of syringe-pleural shunt (SPS) as an alternative for treatment of syringomyelia. We reported a retrospective 26 cases of syringomyelia were found to have indication for a diversion procedure. SPS was offered. Patients' symptoms, mJOA score, and MRI were collected to evaluate the change of the syringomyelia and prognosis of the patients. 2-tailed wilcoxon signed-rank test was used to perform the statistical analysis of the mJOA scores. All 26 patients underwent SPS. The clinical information was collected, the mean follow-up time was 27.4 months, 2-tailed wilcoxon signed-rank test was used to perform the statistical analysis of the mJOA scores. The key surgical technique, outcome and complications of SPS were reported in detail. No mortality and severe complications occurred. Postoperative MRIs revealed near-complete resolution of syrinx in 14 patients, significant shrinkage of syrinx in 10 patients, no obvious reduction or unchanged in remaining 2 patient. Postoperatively, the symptoms improved in 24 cases (92.3%). Statistical analysis of the mJOA scores showed a statistical significance (P<0.001) between the preoperative group and the 2-week postoperative group. No further significant improvement between 2 weeks to the final follow up at 27 months. Collapse or remarkable shrinkage of the syrinx by SPS could ameliorate or at least stabilize the symptoms for the patient. We recommend small laminectomy and a less than 3mm myelotomy either at PML or DREZ. The SPS procedure can be an effective and relatively long-lived treatment for the idiopathic syringomyelia and those that failed other options. Copyright © 2015 Elsevier B.V. All rights reserved.
Impedance Changes Indicate Proximal Ventriculoperitoneal Shunt Obstruction In Vitro.
Basati, Sukhraaj; Tangen, Kevin; Hsu, Ying; Lin, Hanna; Frim, David; Linninger, Andreas
2015-12-01
Extracranial cerebrospinal fluid (CSF) shunt obstruction is one of the most important problems in hydrocephalus patient management. Despite ongoing research into better shunt design, robust and reliable detection of shunt malfunction remains elusive. The authors present a novel method of correlating degree of tissue ingrowth into ventricular CSF drainage catheters with internal electrical impedance. The impedance based sensor is able to continuously monitor shunt patency using intraluminal electrodes. Prototype obstruction sensors were fabricated for in-vitro analysis of cellular ingrowth into a shunt under static and dynamic flow conditions. Primary astrocyte cell lines and C6 glioma cells were allowed to proliferate up to 7 days within a shunt catheter and the impedance waveform was observed. During cell ingrowth a significant change in the peak-to-peak voltage signal as well as the root-mean-square voltage level was observed, allowing the impedance sensor to potentially anticipate shunt malfunction long before it affects fluid drainage. Finite element modeling was employed to demonstrate that the electrical signal used to monitor tissue ingrowth is contained inside the catheter lumen and does not endanger tissue surrounding the shunt. These results may herald the development of "next generation" shunt technology that allows prediction of malfunction before it affects patient outcome.
Hunt, Geraldine B; Culp, William T N; Mayhew, Kelli N; Mayhew, Philipp; Steffey, Michele A; Zwingenberger, Allison
2014-10-01
To evaluate the in vivo pattern of ameroid constrictor closure of congenital extrahepatic portosystemic shunts in dogs. Prospective study. Dogs (n = 22) with congenital extrahepatic portosystemic shunts. Contrast-enhanced computed tomography was performed immediately before, and at least 8 weeks after placement of ameroid ring constrictors. Plastic-encased ameroid constrictors were used in 17 dogs and metal constrictors in 5 dogs. Presence of residual flow through the portosystemic shunt, additional anomalous vessels, acquired shunts and soft tissue associated with the ameroid constrictor was recorded. Postoperative internal diameter was recorded for the 17 plastic constrictors. Correlations between internal diameter and pre- and postoperative serum protein concentration were analyzed. No ameroid constrictor closed completely: shunt occlusion was always dependent on soft tissue within the ameroid ring. Residual flow through the shunt was present in 4 dogs (18%), although this caused persistent elevation of shunt fraction in only 1 dog (dog 8). The change in ameroid constrictor internal diameter was not significantly correlated with serum protein concentration. Complete shunt occlusion after AC placement is usually dependent on soft tissue reaction. Ameroid constrictors ≥5 mm diameter may not promote complete shunt occlusion. © Copyright 2014 by The American College of Veterinary Surgeons.
Effect of bladder augmentation on VP shunt failure rates in spina bifida.
Gonzalez, Dani O; Cooper, Jennifer N; McLeod, Daryl J
2017-12-11
Most patients with spina bifida require ventriculoperitoneal (VP) shunt placement. Some also require bladder augmentation, which may increase the risk of VP shunt malfunction and/or failure. The aim of this study was to assess whether bladder augmentation affects the rate of VP shunt failure in this population. Using the Pediatric Health Information System, we studied patients with spina bifida born between 1992 and 2014 who underwent VP shunt placement. Using conditional logistic regression, we compared age- and hospital-matched patients who did and did not undergo a bladder augmentation to determine their difference in rates of VP shunt failure. There were 4192 patients with spina bifida who underwent both surgical closure and VP shunt placement. Of these, 203 patients with bladder augmentation could be matched to 593 patients without bladder augmentation. VP shunt failure occurred within 2 years in 7.7% of patients, the majority of whom were in the group who underwent bladder augmentation (87%). After adjusting for confounders, undergoing bladder augmentation was independently associated with VP shunt failure (HR: 33.5, 95% CI: 13.15-85.44, p< 0.001). Bladder augmentation appears to be associated with VP shunt failure. Additional studies are necessary to better define this relationship and identify risk-reduction techniques.
Czosnyka, Z; van den Boogaard, F; Czosnyka, M; Momjian, S; Gelling, L; Pickard, J D
2005-01-01
Previously, we documented association between CSF circulation and transcranial-Doppler derived autoregulation in non-shunted patients suffering from hydrocephalus. In the present study we sought to investigate the relationship between the resistance to CSF outflow and pressure-reactivity both in shunted and non-shunted NPH patients. Sixty-eight patients (47 non-shunted and 21 shunted) with NPH have been examined as a part of routine diagnostic procedure. Resistance to CSF outflow (Rcsf) was measured using a ventricular constant rate infusion test. Cerebrovascular pressure-reactivity was assessed as a moving correlation coefficient (PRx) between coherent 'slow waves' of ICP and arterial blood pressure (ABP). This variable has previously been demonstrated to correlate with the autoregulation of CBF in patients following head injury. Results. In non-shunted patients cerebrovascular pressure-reactivity (PRx) was negatively correlated with Rcsf (R = -0.5; p < 0.0005). This relationship was inverted in shunted patients: a positive correlation between PRx and Rcsf was found (R = 0.51; p < 0.03). Cerebrovascular pressure-reactivity is disturbed in patients with normal resistance to CSF outflow, suggesting underlying cerebrovascular disease. This result confirms our previous finding where transcranial Doppler autoregulation was investigated. After shunting the pressure-reactivity strongly depends on shunt functioning and deteriorates when the shunt is blocked.
Gallagher, Ryan; Marquez, Jodie; Osmotherly, Peter
2018-04-25
To identify in patients with idiopathic normal pressure hydrocephalus (iNPH) undergoing a cerebrospinal fluid (CSF) tap test (TT) for consideration of a ventricular peritoneal (VP) shunt: (1) gait and balance measures, which identify symptom change; (2) differences present between pre- and post-CSF TT scores between patients classified as responders and nonresponder; (3) ability of patients with iNPH to accurately quantify change in their gait and balance symptoms from a CSF TT. Prospective observational study. Post-CSF TT assessment was completed 2-4 hours post. Tertiary referral neurological and neurosurgical hospital. Patients (N=74) with iNPH receiving a 30 mL CSF TT for consideration of a VP shunt. Patients underwent a battery of gait and balance measures pre- and post-CSF TT and indicated their perceived change on a global rating of change (GRC). Patients deemed to improve and offered VP shunt insertion by a neurologist or neurosurgeon were labeled responders. Performance oriented mobility assessment (Tinetti), Berg Balance Scale (BBS), timed Up and Go (TUG), 10-meter walk test (10MWT), GRC. Forty patients were classified responders, 34 nonresponders. Significant differences were identified for responders: Tinetti (3.88 points), TUG (3.98 seconds), 10MWT (0.08 m/sec), and BBS (5.29 points). Significant differences were found for nonresponders for the Tinetti (0.91 points) and BBS (2.06 points). Change scores for responders and nonresponders were significantly different for all tests between responders and nonresponders. GRC scores for gait (+2 for responders, 0 for nonresponders) and balance (+2.5 for responders, 0 for nonresponders) were both significantly different. The Tinetti, BBS, and TUG can identify change in patients undergoing a CSF TT for iNPH. Patients appear to be able to accurately identify if change has occurred. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Biglino, Giovanni; Giardini, Alessandro; Hsia, Tain-Yen; Figliola, Richard; Taylor, Andrew M.; Schievano, Silvia
2013-01-01
First stage palliation of hypoplastic left heart syndrome, i.e., the Norwood operation, results in a complex physiological arrangement, involving different shunting options (modified Blalock-Taussig, RV-PA conduit, central shunt from the ascending aorta) and enlargement of the hypoplastic ascending aorta. Engineering techniques, both computational and experimental, can aid in the understanding of the Norwood physiology and their correct implementation can potentially lead to refinement of the decision-making process, by means of patient-specific simulations. This paper presents some of the available tools that can corroborate clinical evidence by providing detailed insight into the fluid dynamics of the Norwood circulation as well as alternative surgical scenarios (i.e., virtual surgery). Patient-specific anatomies can be manufactured by means of rapid prototyping and such models can be inserted in experimental set-ups (mock circulatory loops) that can provide a valuable source of validation data as well as hydrodynamic information. Such models can be tuned to respond to differing the patient physiologies. Experimental set-ups can also be compatible with visualization techniques, like particle image velocimetry and cardiovascular magnetic resonance, further adding to the knowledge of the local fluid dynamics. Multi-scale computational models include detailed three-dimensional (3D) anatomical information coupled to a lumped parameter network representing the remainder of the circulation. These models output both overall hemodynamic parameters while also enabling to investigate the local fluid dynamics of the aortic arch or the shunt. As an alternative, pure lumped parameter models can also be employed to model Stage 1 palliation, taking advantage of a much lower computational cost, albeit missing the 3D anatomical component. Finally, analytical techniques, such as wave intensity analysis, can be employed to study the Norwood physiology, providing a mechanistic perspective on the ventriculo-arterial coupling for this specific surgical scenario. PMID:24400277
Complications of congenital portosystemic shunts in children: therapeutic options and outcomes.
Franchi-Abella, Stéphanie; Branchereau, Sophie; Lambert, Virginie; Fabre, Monique; Steimberg, Clarisa; Losay, Jean; Riou, Jean-Yves; Pariente, Danièle; Gauthier, Frédéric; Jacquemin, Emmanuel; Bernard, Olivier
2010-09-01
Congenital portosystemic shunts are rare vascular malformations that lead to severe complications. Their management is controversial. The aim of this study was to propose a clear definition of the risks and management of congenital portosystemic shunts in children according to our experience and a review of the literature. Twenty-two children with a complicated congenital portosystemic shunt were studied in our institution. When necessary, management included portal pressure measurement and portal vein angiography during an occlusion test and closure of the shunt by surgical and/or endovascular methods. Five neonates with intrahepatic shunts presented with cholestasis that resolved spontaneously, and 17 older children presented with liver tumors (13) and/or hepatopulmonary syndrome (2), pulmonary artery hypertension (3), portosystemic encephalopathy (3), heart failure (1), and glomerulonephritis (1). The portosystemic shunt was extrahepatic (11) or intrahepatic (6). Portosystemic shunts were closed by endovascular methods in 5 children and surgically in 10, 4 of whom had portal pressure during occlusion above 35 mmHg and extremely hypoplastic or undetectable portal veins requiring banding of the fistula before closure. Shunt closure resulted in restoration of intrahepatic portal flow in all, with complete or partial regression of benign liver masses, and regression or stabilization of pulmonary, cardiac, neurological, and renal complications. Congenital portosystemic shunt carries risks of severe complications in children. Closure of a shunt persisting after age 2 years should be considered preventively. Intrahepatic portal flux restoration can be expected, even when intrahepatic portal veins are extremely hypoplastic or undetectable.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harvey, Steven P.; Moseley, John; Norman, Andrew
We investigated the potential-induced degradation (PID) shunting mechanism in multicrystalline-silicon photovoltaic modules by using a multiscale, multitechnique characterization approach. Both field-stressed modules and laboratory-stressed mini modules were studied. We used photoluminescence, electroluminescence, and dark lock-in thermography imaging to identify degraded areas at the module scale. Small samples were then removed from degraded areas, laser marked, and imaged by scanning electron microscopy. We used simultaneous electron-beam induced current imaging and focused ion beam milling to mark around PID shunts for chemical analysis by time-of-flight secondary-ion mass spectrometry or to isolate individual shunt defects for transmission electron microscopy and atom-probe tomography analysis.more » By spanning a range of 10 orders of magnitude in size, this approach enabled us to investigate the root-cause mechanisms for PID shunting. We observed a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiNX/Si interface and is consistently observed at a concentration of 0.1% to 2% in shunted areas. Analysis of samples subjected to PID recovery, either activated by electron beam or thermal effects only, reveals that recovery of isolated shunts correlates with diffusion of sodium out of the structural defects to the silicon surface. We observed the role of oxygen and chlorine in PID shunting and found that those species - although sometimes present in structural defects where PID shunting was observed - do not play a consistent role in PID shunting.« less
49 CFR 236.725 - Circuit, switch shunting.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Circuit, switch shunting. 236.725 Section 236.725 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Circuit, switch shunting. A shunting circuit which is closed through contacts of a switch circuit...
49 CFR 236.725 - Circuit, switch shunting.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Circuit, switch shunting. 236.725 Section 236.725 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Circuit, switch shunting. A shunting circuit which is closed through contacts of a switch circuit...
49 CFR 236.725 - Circuit, switch shunting.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Circuit, switch shunting. 236.725 Section 236.725 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Circuit, switch shunting. A shunting circuit which is closed through contacts of a switch circuit...
49 CFR 236.725 - Circuit, switch shunting.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Circuit, switch shunting. 236.725 Section 236.725 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Circuit, switch shunting. A shunting circuit which is closed through contacts of a switch circuit...
49 CFR 236.725 - Circuit, switch shunting.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Circuit, switch shunting. 236.725 Section 236.725 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Circuit, switch shunting. A shunting circuit which is closed through contacts of a switch circuit...
NASA Technical Reports Server (NTRS)
Appelbaum, J.; Singer, S.
1989-01-01
A calculation of the starting torque ratio of permanent magnet, series, and shunt-excited dc motors powered by solar cell arrays is presented for two cases, i.e., with and without a maximum-power-point tracker (MPPT). Defining motor torque magnification by the ratio of the motor torque with an MPPT to the motor torque without an MPPT, a magnification of 3 for the permanent magnet motor and a magnification of 7 for both the series and shunt motors are obtained. The study also shows that all motor types are less sensitive to solar insolation variation in systems including MPPTs as compared to systems without MPPTs.
Post-traumatic hepatic arterial pseudoaneurysm and arterioportal shunt.
Maes, J; D'Archambeau, O; Snoeckx, A; Op de Beeck, B; Voormolen, M; Parizel, P M
2010-01-01
The authors report the case of a 21-year-old man who suffered from a blunt abdominal trauma. Initial imaging revealed a liver laceration at the right lobe, a perirenal hematoma of the right kidney and a hematoma of the right adrenal gland. Follow-up MDCT-scan on day 10 after admission showed at the arterial-phase contrast-enhanced study perfusion alterations and two hepatic pseudoaneurysms. The diagnosis of pseudoaneurysm was confirmed and treated angiographically with superselective coil embolization. A follow-up CT-scan on day 17 showed at a nontreated area an arterioportal shunt and a wedge-shaped transient hepatic parenchymal enhancement. This was confirmed angiographically and subsequently treated with coil embolization.
[Migraine and cadiac shunts - is there a link?].
Riederer, Franz
2012-10-17
Recently an association between migraine and cardiac shunts (e.g. through a patent foramen ovale, PFO) has been described. There is evidence from mostly retrospective case series that PFO closure can significantly improve migraine. On the other hand an increase in attack frequency or de novo migraine after percutaneous closure of an atrial septal defect has been described. Animal experiments showed that microemboli in the cerebral circulation can trigger a cortical spreading depression, which is believed the pathophysiological substrate of migraine aura. A randomized controlled trial that investigated PFO closure for treatment resistant migraine with aura was negative. It is currently discussed whether certain subgroups, who have a high risk for paradoxical embolism, might improve after PFO closer.
Grimaldi, Chiara; Monti, Lidia; Falappa, Piergiorgio; d'Ambrosio, Giuseppe; Manca, Antonio; de Ville de Goyet, Jean
2012-02-01
Congenital intrahepatic portosystemic shunts are rare hepatic vascular anomalies that often lead to severe secondary conditions. A 6-year-old boy was referred for assessment of severe hypoxia, and a large liver mass was diagnosed with such a malformation and was managed by direct closure of the venous fistula by interventional radiology. Follow-up assessment shows normalization of the respiratory condition and a progressive reduction of the vascular liver lesion. Review of literature suggests that radiologic interventions are currently the criterion standard for managing these conditions, with surgery reserved for patients who are not eligible for radiologic procedure and those requiring liver transplantation. Copyright © 2012 Elsevier Inc. All rights reserved.
Remittent hyperammonemia in congenital portosystemic shunt.
Ferrero, Giovanni Battista; Porta, Francesco; Biamino, Elisa; Mussa, Alessandro; Garelli, Emanuela; Chiappe, Francesca; Veltri, Andrea; Silengo, Margherita Cirillo; Gennari, Fabrizio
2010-03-01
Congenital portosystemic shunts (PSS) are rare vascular anomalies with different gross anatomy. Persistent patent ductus venosus (PDV) represents an uncommon cause of intrahepatic PSS. The diagnosis of this condition may not be obvious because of its wide spectrum of clinical manifestations, ranging from asymptomatic to life-threatening disease. We report the case of three boys with neuropsychological symptoms associated with mild fasting hyperammonemia. An oral protein load allowed the detection of a detoxication defect due to PSS related to PDV. This simple procedure can be worthwhile of attention in patients with mental retardation, behavior disturbances, and learning difficulties after exclusion of common causes of inherited hyperammonemia, namely, urea cycle disorders, organic acidemias, and fatty acid oxidation defects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carnevale, Francisco Cesar, E-mail: fcarnevale@uol.com.br; Santos, Aline Cristine Barbosa; Tannuri, Uenis
We report the case of a 9-year-old boy with portal hypertension, due to Budd-Chiari syndrome, and retrohepatic inferior vena cava thrombosis, submitted to a transjugular intrahepatic portosystemic shunt (TIPS) by connecting the suprahepatic segment of the inferior vena cava directly to the portal vein. After 3 months, the withdrawal of anticoagulants promoted the thrombosis of the TIPS. At TIPS revision, thrombosis of the TIPS and the main portal vein and clots at the splenic and the superior mesenteric veins were found. Successful angiography treatment was performed by thrombolysis and balloon angioplasty of a severe stenosis at the distal edge ofmore » the stent.« less
Rangel-Abundis, Alberto
2006-01-01
Shunt and short circuit are antonyms. In French, the term shunt has been adopted to denote the alternative pathway of blood flow. However, in French, as well as in Spanish, the word short circuit (court-circuit and cortocircuito) is synonymous with shunt, giving rise to a linguistic and scientific inconsistency. Scientific because shunt and short circuit made reference to a phenomenon that occurs in the field of the physics. Because shunt and short circuit are antonyms, it is necessary to clarify that shunt is an alternative pathway of flow from a net of high resistance to a net of low resistance, maintaining the stream. Short circuit is the interruption of the flow, because a high resistance impeaches the flood. This concept is applied to electrical and cardiovascular physiology, as well as to the metabolic pathways.
A wireless monitoring system for Hydrocephalus shunts.
Narayanaswamy, A; Nourani, M; Tamil, L; Bianco, S
2015-08-01
Patients with Hydrocephalus are usually treated by diverting the excess Cerebrospinal Fluid (CSF) to other parts of the body using shunts. More than 40 percentage of shunts implanted fail within the first two years. Obstruction in the shunts is one of the major causes of failure (45 percent) and the detection of obstruction reduces the complexity of the revision surgery. This paper describes a proposed wireless monitoring system for clog detection and flow measurement in shunts. A prototype was built using multiple pressure sensors along the shunt catheters for sensing the location of clog and flow rate. Regular monitoring of flow rates can be used to adjust the valve in the shunt to prevent over drainage or under drainage of CSF. The accuracy of the flow measurement is more than 90 percent.
Research of vibration control based on current mode piezoelectric shunt damping circuit
NASA Astrophysics Data System (ADS)
Liu, Weiwei; Mao, Qibo
2017-12-01
The piezoelectric shunt damping circuit using current mode approach is imposed to control the vibration of a cantilever beam. Firstly, the simulated inductance with large values are designed for the corresponding RL series shunt circuits. Moreover, with an example of cantilever beam, the second natural frequency of the beam is targeted to control for experiment. By adjusting the values of the equivalent inductance and equivalent resistance of the shunt circuit, the optimal damping of the shunt circuit is obtained. Meanwhile, the designed piezoelectric shunt damping circuit stability is experimental verified. Experimental results show that the proposed piezoelectric shunt damping circuit based on current mode circuit has good vibration control performance. However, the control performance will be reduced if equivalent inductance and equivalent resistance values deviate from optimal values.
Unal, Omer Faruk; Aras, Yavuz; Aydoseli, Aydin; Akcakaya, Mehmet Osman
2012-01-01
The optimal treatment for Dandy-Walker malformation is still controversial. Ventriculoperitoneal shunting, cystoperitoneal shunting or combinations are the most common surgical options in the management of this clinical entity. Endoscopic procedures like ventriculocystostomy, 3rd ventriculostomy or endoscopy-assisted shunt surgeries have become the focus of recent publications. We describe a new transcystic endoscopic technique, with the usage of a single ascending transaqueductal shunt catheter with additional holes, whereby both the posterior fossa cyst and supratentorial ventricular compartments are drained effectively. By using this new technique complications associated with combined shunting can be avoided. In addition, by equalizing the pressure within the supra- and infratentorial compartments, the upward or downward herniations associated with single-catheter shunting can be prevented. Copyright © 2013 S. Karger AG, Basel.
Bermo, Mohammed S; Khalatbari, Hedieh; Parisi, Marguerite T
2018-05-08
Successful shunt access is the first step in a properly performed nuclear medicine cerebrospinal fluid (CSF) shunt study. To determine the significance of the radiotracer configuration at the injection site during initial nuclear medicine CSF shunt imaging and the lack of early systemic radiotracer activity as predictors of successful shunt access. With Institutional Review Board approval, three nuclear medicine physicians performed a retrospective review of all consecutive CSF shunt studies performed in children at our institution in 2015. Antecedent nuclear medicine CSF shunt studies in these patients were also assessed and included in the review. The appearance of the reservoir site immediately after radiotracer injection was classified as either figure-of-eight or round/ovoid configuration. The presence or absence of early systemic distribution of the tracer on the 5-min static images was noted and separately evaluated. A total of 98 nuclear medicine ventriculoperitoneal CSF shunt studies were evaluated. Figure-of-eight configuration was identified in 87% of studies and, when present, had 93% sensitivity, 78% specificity, 92% accuracy, 98% positive predictive value (PPV) and 54% negative predictive value (NPV) as a predictor of successful shunt access. Early systemic activity was absent in 89 of 98 studies. Lack of early systemic distribution of the radiotracer had 98% sensitivity, 78% specificity, 96% accuracy, 98% PPV and 78% NPV as a predictor of successful shunt access. Figure-of-eight configuration in conjunction with the absence of early systemic tracer activity had 99% PPV for successful shunt access. Figure-of-eight configuration at the injection site or lack of early systemic radiotracer activity had moderate specificity for successful shunt access. Specificity and PPV significantly improved when both signs were combined in assessment.
Khanmoradi, Kamran; Defaria, Werviston; Nishida, Seigo; Levi, David; Kato, Tomoaki; Moon, Jang; Selvaggi, Gennaro; Tzakis, Andreas
2009-05-01
We describe our experience with a modification of the piggyback (PB) technique for orthotopic liver transplantation in which the donor infrahepatic vena cava is used as the venous outflow tract. From May 1997 to January 2006, a total of 109 cases using this technique were performed in 101 patients. Collected data included recipient demographics and diagnosis, warm ischemia time, use of venovenous bypass or temporary portacaval shunt and complications related to the venous outflow and graft, and patient survival. Data were compared with the patients undergoing standard PB technique during the same period. The reasons for using the technique were grouped according to whether there was a problem with the recipient hepatic veins or a concern about the length or diameter of the donor suprahepatic vena cava. These included the presence of a transjugular intrahepatic portosystemic shunt (eight cases), retransplantation (22 cases), thin-walled, friable hepatic veins (32 cases), Budd-Chiari syndrome (two cases), domino liver procurement (six cases), reduced or split liver grafts (five cases), and graft inferior vena cava to recipient hepatic veins size discrepancy (34 cases). There was no graft loss. The warm ischemia time was 39.65 minutes compared with 37 minutes in the standard PB group. The long-term graft and patient survival rates were similar in the two groups. Infrahepatic vena cavocavostomy is a useful variation of the standard PB technique.
NASA Astrophysics Data System (ADS)
Qin, Guoxuan; Yuan, Hao-Chih; Celler, George K.; Zhou, Weidong; Ma, Zhenqiang
2009-12-01
This paper reports the realization of flexible RF/microwave PIN diodes and switches using transferrable single-crystal Si nanomembranes (SiNM) that are monolithically integrated on low-cost, flexible plastic substrates. High frequency response is obtained through the realization of low parasitic resistance achieved with heavy ion implantation before nanomembrane release and transfer. The flexible lateral SiNM PIN diodes exhibit typical rectifying characteristics with insertion loss and isolation better than 0.9 dB and 19.6 dB, respectively, from DC to 5 GHz, as well as power handling up to 22.5 dBm without gain compression. A single-pole single-throw (SPST) flexible RF switch employing shunt-series PIN diode configuration has achieved insertion loss and isolation better than 0.6 dB and 22.9 dB, respectively, from DC to 5 GHz. Furthermore, the SPST microwave switch shows performance improvement and robustness under mechanical deformation conditions. The study demonstrates the considerable potential of using properly processed transferrable SiNM for microwave passive components. Future investigations on transferrable SiNMs will lead to eventual realization of monolithic microwave integrated systems on low-cost flexible substrates.
Puledda, Francesca; Toscano, Massimiliano; Pieroni, Alessio; Veneroso, Gabriele; Di Piero, Vittorio; Vicenzini, Edoardo
2016-02-01
Air-saline transcranial Doppler is nowadays the first-choice examination to identify right-to-left shunt. To increase right-to-left shunt detection in echocardiography, cardiologists also use air-gelatin mixtures, which are more stable, more echogenic, and easier to be prepared. We assessed the sensitivity of air-gelatin compared with air-saline for transcranial Doppler right-to-left shunt detection. Air-saline transcranial Doppler, during unilateral middle cerebral artery monitoring at rest and after Valsalva maneuver, was performed in patients referred to our neurosonology laboratory for right-to-left shunt detection. The same transcranial Doppler protocol was repeated with air-gelatin. To consider transcranial Doppler positive for cardiac right-to-left shunt, at least one embolic signal had to be detected within 20″ from contrast injection. Later signals were interpreted of pulmonary origin. Trans-thoracic echocardiography was repeated with both air-saline and air-gelatin. A total of 97 patients were enrolled; 46 had negative transcranial Doppler for cardiac right-to-left shunt with both air-saline and air-gelatin; out of these, four patients with air-saline plus two more patients with air-gelatin presented late, isolated microemboli, slightly more numerous with air-gelatin: these were interpreted as pulmonary shunts and confirmed with trans-thoracic echocardiography. In 28 patients with already early positive air-saline transcranial Doppler at rest, air-gelatin induced a marked right-to-left shunt increase, facilitating its visualization at trans-thoracic echocardiography. In 23 patients in whom air-saline transcranial Doppler was negative at rest and positive for cardiac right-to-left shunt only after Valsalva maneuver, air-gelatin was able to reveal shunt also at rest. Air-gelatin increases right-to-left shunt detection sensitivity with transcranial Doppler in particular at rest, even in patients in whom air-saline mixture fails to identify the shunt. The choice of air-gelatin mixture should be considered for multicentric, clinical, and research trials. © 2016 World Stroke Organization.
Abnormalities of the umbilico-portal venous system in Down syndrome: a report of two new patients.
Pipitone, Salvatore; Garofalo, Caterina; Corsello, Giovanni; Mongiovì, Maurizio; Piccione, Maria; Maresi, Emiliano; Sperandeo, Velio
2003-08-01
Congenital anomalies of the umbilical and portal venous system are rare vascular malformations which are often associated with anomalies of the heart and gastrointestinal tract. Association with chromosomal disorders has been sporadically reported. We now report on two patients with trisomy 21 and congenital anomalies of the umbilico-portal system. A male fetus showed absence of the intrahepatic portal vein (PV) and ductus venosus with a direct communication between portal sinus and inferior vena cava exhibiting an umbilicosystemic total shunt during the fetal life and a portosystemic total shunt after birth. A female infant showed absence of the intrahepatic PV and a total portocaval shunt. Both patients also had heart defects. As previously documented in other reports, our cases demonstrated that this association may be causally-related to the chromosomal aberration. In addition, the umbilico-portal venous system abnormalities seems to be the most frequent congenital vascular malformation in Down syndrome. A presumptive pathogenetic mechanism could be a trisomy 21-related altered angiogenesis of the vitelloumbilical plexus. Copyright 2003 Wiley-Liss, Inc.
Endoscopic third ventriculostomy for hydrocephalus in brainstem glioma: a case series.
Kobayashi, Natsuki; Ogiwara, Hideki
2016-07-01
A brainstem glioma is an incurable brain tumor that can be complicated by hydrocephalus. A ventriculoperitoneal (VP) shunt is generally performed for the control of hydrocephalus. This study aimed to reveal the safety and efficacy of an endoscopic third ventriculostomy (ETV) for hydrocephalus in brainstem gliomas. Six patients who had pontine glioma with hydrocephalus underwent an ETV between May 2010 and November 2015. In all the cases, there were one or more symptoms of hydrocephalus (headache, nausea, vomiting, or lethargy). Retrospective review of these patients was performed using the medical records and neuroimagings. The ETV was performed safely and there were no intraoperative complications in all patients. The mean follow-up period was 12.3 months. An immediate symptomatic relief of hydrocephalus and an adequate control of symptoms were achieved without a VP shunt in all patients. The ETV is considered to be an effective and safe procedure for the treatment of hydrocephalus in brainstem gliomas. Determining the ventriculostomy site according to the preoperative MRI in each case is considered to be important for the safe procedure.
2013-10-01
echocardiography to determine bubble/shunt scores. We will also use nuclear medicine imaging to determine shunt fractions following acute exposures to... echocardiography while breathing hypoxic gas mixtures. – TASK COMPLETED. For Task #1.3 “Quantify shunt during hypoxic exposure with SPECT CT – PFO...subjects.” 19 PFO+ subjects have completed saline contrast echocardiography while breathing hypoxic gas mixtures for 30 min. One PFO+ subject that had
Kehler, Uwe; Langer, Niels; Gliemroth, Jan; Meier, Ullrich; Lemcke, Johannes; Sprung, Christian; Schlosser, Hans-Georg; Kiefer, Michael; Eymann, Regina; Heese, Oliver
2012-05-01
Shunt obstructions may partly be caused by brain debris, which intrude into the ventricular catheter during ventricle puncture. Avoiding contact between the catheter and brain tissue, by using a peel-away sheath, should reduce the number of shunt failures caused by obstruction. To test this hypothesis, we conducted a randomized, prospective multicenter study. 201 patients from 6 different neurosurgical centers in Germany receiving a ventriculo-peritoneal shunt were included in this study. Of these, 177 patients completed a 1-year follow-up period. Surgery was randomized in a 1 to 1 fashion, such that out of 177 procedures, 91 were performed using a peel-away sheath and 86 were performed without. The rate of surgical re-interventions and shunt obstructions within a 12-month period was recorded. Within 1 year post-surgery, 17 shunt obstructions (9.6%) leading to shunt revisions were recorded. However, no difference was found between surgeries performed using a peel-away sheath (9.9%) or not (9.3%). The overall shunt infection rate was 2.8% and the shunt revision rate for overdrainage was 3.9%. The theoretical advantages attributed to the use of a peel-away sheath to introduce a ventricular catheter could not be confirmed in this randomized study, suggesting that the proposed role of brain debris in shunt obstructions may be overestimated. Copyright © 2011 Elsevier B.V. All rights reserved.
Xie, Hui; Bian, Yitong; Jian, Zhijie; Huo, Kang; Liu, Rui; Zhu, Dan; Zhang, Lihui; Wu, Jun; Yang, Jian; Liu, Jixin; Luo, Guogang
2018-01-01
Numerous studies have indicated an association between migraine and right-to-left shunt. However, little is known about whether right-to-left shunt has an effect on the migraine brain. This observational study aims to explore the impact of right-to-left shunt on the brain of migraine without aura on microstructural level. Thirty-five patients with migraine without aura were enrolled in this study. Contrast-enhanced Transcranial Doppler was performed to evaluate the status of right-to-left shunt. Three-dimensional T1-weighted and diffusion tensor images were acquired for data analysis. We employed voxel-based morphometry and tract-based spatial statistical analyses to assess the differences of gray and white matter between migraineurs with and without right-to-left shunt, respectively. Among the 35 patients, 19 (54.3%) patients had right-to-left shunt. There were no significant differences in headache features between migraineurs with and without right-to-left shunt. There were significant increases of mean and radial diffusivity in migraineurs with right-to-left shunt compared with migraineurs without right-to-left shunt. The alterations were primarily located in the right posterior thalamic radiation, secondly in the body of corpus callosum and the right superior corona radiata. No significant differences were observed in values of fractional anisotropy and axial diffusivity. No significant between-group differences were found in gray matter volume. Right-to-left shunt may cause alterations of white matter integrity in migraine without aura, and the alterations are more likely to be located at the posterior circulation.
Miyake, H; Ohta, T; Kajimoto, Y; Deguchi, J
1999-01-01
The indications for cerebrospinal fluid (CSF) shunting in patients with normal pressure hydrocephalus (NPH) have not been established. Establishment of clear-cut indications for this procedure is essential to ensure cost-effective, and safe treatment. We report the usefulness of the Diamox((R)) challenge test in evaluating indications for CSF shunting in patients with NPH. Pre- and post-operative responses in cerebral blood flow (CBF) and intracranial pressure (ICP) to intravenous administration of Diamox((R)) 1000mg (Diamox((R)) administration) were analysed in 41 patients with NPH who were treated by ventriculoperitoneal (VP) shunt with a programmable valve and an on-off valve. The preoperative response of ICP to Diamox((R)) administration was more than 10 mmHg in most patients in whom the shunt was effective (shunt effective group), however, it was less than 10 mmHg in most patients in whom the shunt was ineffective (shunt non-effective group). Furthermore, the postoperative response of ICP to Diamox((R)) administration decreased to less than 10 mmHg in most patients in the shunt effective group. The increases in CBF in response to Diamox((R)) administration were similar in the two groups both before and after placement of the VP shunt. Patients in whom ICP increased by more than 10 mmHg in response to Diamox((R)) administration were regarded to have poor CSF circulation and to thus be candidates for CSF shunting. The Diamox((R)) challenge test is a simple, safe procedure, useful in evaluating the response to treatment.
[Intrauterine devices in the immediate, early and late postabortion period].
Nun, S
1971-01-01
2146 cases of IUD insertions after hospitalization for abortion at a hospital in Chile were studied. In 1514 cases the IUDs were inserted immediately after abortion, in 430 cases between 1-5 days after the operation, and in 202 cases between 5-40 days after. It is concluded that immediate or early insertion results in a somewhat lower retention rate, but offers the advantage of making it possible to treat a greater number of patients, many of whom would not return later to have the IUD inserted. The incidence of removal for medical causes was very low and immediate insertion was found to be harmless. The medical causes of removal were the usual ones of bleeding, pain, and infection; the most frequent cause of interruption of use was expulsion, which tends to occur during the 1st few months of use and among younger women. The probability of failure due to pregnancy was somewhat higher than in the case of insertion during the intermenstrual period. Cases of voluntary removal tend to increase after prolonged use, and a study to analyze the actual reasons for this fact is necessary.
Transjugular intrahepatic portosystemic shunt creation using intravascular ultrasound guidance.
Farsad, Khashayar; Fuss, Cristina; Kolbeck, Kenneth J; Barton, Robert E; Lakin, Paul C; Keller, Frederick S; Kaufman, John A
2012-12-01
To describe the use of intravascular ultrasound (US) guidance for creation of transjugular intrahepatic portosystemic shunts (TIPSs) in humans. The initial 25 cases of intravascular US-guided TIPS were retrospectively compared versus the last 75 conventional TIPS cases during the same time period at the same institution in terms of the number of needle passes required to establish portal vein (PV) access, fluoroscopy time, and needle pass-related complications. Intravascular US-guided TIPS creation was successful in all cases, and there was no statistically significant difference in number of needle passes, fluoroscopy time, or needle pass-related complications between TIPS techniques. Intravascular US-guided TIPS creation was successful in cases in which conventional TIPS creation had failed as a result of PV thrombosis or distorted anatomy. Intravascular US guidance for TIPS creation was additionally useful in a patient with Budd-Chiari syndrome and in a patient with intrahepatic tumors. Intravascular US is a safe and reproducible means of real-time image guidance for TIPS creation, equivalent in efficacy to conventional fluoroscopic guidance. Real-time sonographic guidance with intravascular US may prove advantageous for cases in which there is PV thrombus, distorted anatomy, Budd-Chiari syndrome, or hepatic tumors. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
Aneurysmal portahepatic venous fistula: Report of two cases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chagnon, S.F.; Vallee, C.A.; Barge, J.
1986-06-01
Two cases are reported of congenital intrahepatic portacaval shunts in middle-aged women who had encephalopathy or hypoglycemia. Real-time ultrasound (US) investigations revealed vascular communication between the left portal and hepatic veins in one patient and communication between the right portal and hepatic veins in the other. These findings were confirmed using angiography with pressure measurement. One patient underwent surgery; the other received dietetic treatment. The findings in these two cases are compared with those of three previously reported cases.
Patient data system for monitoring shunts.
Frank, E; Su, E; Smith, K
1988-01-01
Rapidly locating accurate data on a patient's shunt system is often extremely difficult. We have developed a simple system to fill a perceived need for recording current data on a patients shunt. This system employs an easily updated record in the patient's hospital or clinic chart as well as a wallet-sized data card for the patient or his family to carry. The data in the chart include the configuration of the patient's current shunt system and a graphic record of previous shunt problems. The small patient data card describes the age of the shunt system and its current configuration. We have found that this system provides assistance in the routine follow-up of patients with shunts and plays an extremely necessary role in the emergency evaluation of these patients, particularly when an emergency evaluation is undertaken in facilities distant from the location of regular treatment.
Harvey, Steven P.; Aguiar, Jeffery A.; Hacke, Peter; ...
2016-09-19
Here, we investigated potential-induced degradation (PID) in silicon mini-modules that were subjected to accelerated stressing to induce PID conditions. Shunted areas on the cells were identified with photoluminescence and dark lock-in thermography (DLIT) imaging. The identical shunted areas were then analyzed via time-of-flight secondary-ion mass spectrometry (TOFSIMS) imaging, 3-D tomography, and high-resolution transmission electron microscopy. The TOF-SIMS imaging indicates a high concentration of sodium in the shunted areas, and 3-D tomography reveals that the sodium extends more than 2 um from the surface below shunted regions. Transmission electron microscopy investigation reveals that a stacking fault is present at an areamore » identified as shunted by DLIT imaging. After the removal of surface sodium, tomography reveals persistent sodium present around the junction depth of 300 nm and a drastic difference in sodium content at the junction when comparing shunted and nonshunted regions.« less
49 CFR 236.57 - Shunt and fouling wires.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Shunt and fouling wires. 236.57 Section 236.57...: All Systems Track Circuits § 236.57 Shunt and fouling wires. (a) Except as provided in paragraph (b) of this section, shunt wires and fouling wires hereafter installed or replaced shall consist of at...
49 CFR 236.57 - Shunt and fouling wires.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Shunt and fouling wires. 236.57 Section 236.57...: All Systems Track Circuits § 236.57 Shunt and fouling wires. (a) Except as provided in paragraph (b) of this section, shunt wires and fouling wires hereafter installed or replaced shall consist of at...
Portosystemic shunts for extrahepatic portal hypertension in children.
Tocornal, J; Cruz, F
1981-07-01
Twenty-three children with prehepatic portal hypertension and hemorrhage due to ruptured esophagogastric varices had portosystemic shunts. Their ages ranged from two years and seven months to 15 years. Eleven were less than eight years of age. Twenty patients had portal vein cavernomatosis and three patients had double portal veins. In 21 patients, a mesocaval type of shunt was done. A splenorenal shunt was performed in two. There was no surgical mortality. Two shunts occluded, both in rather young infants--two years and seven months and three years of age. In all the others, there was no further bleeding, and the shunts remained patent, as shown by abdominal angiograms. Neuropsychiatric disorders, probably due to hepatic encephalopathy, occurred in only one patient. On the basis of this favorable experience, we believe that an elective portosystemic shunt should, in general, be performed upon children with prehepatic portal hypertension after one major variceal hemorrhage. We favor a mesocaval type of shunt in these children because of the larger diameter of the vessels involved in the anastomosis and because it preserves the spleen, maintaining defense against subsequent infection.
A novel method for passing cerebrospinal fluid shunt tubing: a proof of principle study.
Tubbs, R Shane; Goodrich, Dylan; Tubbs, Isaiah; Loukas, Marios; Cohen-Gadol, Aaron A
2014-12-01
Few innovations in the method of tunneling shunt tubing for cerebrospinal fluid (CSF) shunt diversion have been made since this treatment of hydrocephalus was first developed. Therefore, this feasibility study was performed with the hope of identifying an improved technique that could potentially carry fewer complications. On 10 cadaver sides and when placed in the supine position, small skin incisions were made at the clavicle and ipsilateral subcostal region, and magnets were used to pass standard shunt tubing between the two incisions. Nickel-plated magnets were less effective in pulling the shunt tubing below the skin compared with ceramic magnets. Of these, magnets with pull strengths of 150-200 lbs were the most effective in dragging the subcutaneous tubing between the two incisions. No obvious damage to the skin from the overlying magnet was seen in any specimen. Few options exist for tunneling distal shunt tubing for CSF shunt procedures. Future patient studies are needed to determine if the technique described herein is superior to current methods, particularly when examining patient groups that are at a greater risk for injury during tunneling shunt catheters.
Are Shunt Revisions Associated with IQ in Congenital Hydrocephalus? A Meta -Analysis.
Arrington, C Nikki; Ware, Ashley L; Ahmed, Yusra; Kulesz, Paulina A; Dennis, Maureen; Fletcher, Jack M
2016-12-01
Although it is generally acknowledged that shunt revisions are associated with reductions in cognitive functions in individuals with congenital hydrocephalus, the literature yields mixed results and is inconclusive. The current study used meta-analytic methods to empirically synthesize studies addressing the association of shunt revisions and IQ in individuals with congenital hydrocephalus. Six studies and three in-house datasets yielded 11 independent samples for meta-analysis. Groups representing lower and higher numbers of shunt revisions were coded to generate effect sizes for differences in IQ scores. Mean effect size across studies was statistically significant, but small (Hedges' g = 0.25, p < 0.001, 95 % CI [0.08, 0.43]) with more shunt revisions associated with lower IQ scores. Results show an association of lower IQ and more shunt revisions of about 3 IQ points, a small effect, but within the error of measurement associated with IQ tests. Although clinical significance of this effect is not clear, results suggest that repeated shunt revisions because of shunt failure is associated with a reduction in cognitive functions.
Congenital portosystemic shunts: imaging findings and clinical presentations in 11 patients.
Konstas, Angelos A; Digumarthy, Subba R; Avery, Laura L; Wallace, Karen L; Lisovsky, Mikhail; Misdraji, Joseph; Hahn, Peter F
2011-11-01
To evaluate the clinical anatomy and presentations of congenital portosystemic shunts, and determine features that promote recognition on imaging. Institutional review board approval was obtained for this HIPAA-compliant study. The requirement for written informed consent was waived. Radiology reports were retrospectively reviewed from non-cirrhotic patients who underwent imaging studies from January 1999 through February 2009. Clinical sources reviewed included electronic medical records, archived images and histopathological material. Eleven patients with congenital portosystemic shunts were identified (six male and five female; age range 20 days to 84 years). Seven patients had extrahepatic and four patients had intrahepatic shunts. All 11 patients had absent or hypoplastic intrahepatic portal veins, a feature detected by CT and MRI, but not by US. Seven patients presented with shunt complications and four with presentations unrelated to shunt pathophysiology. Three adult patients had four splenic artery aneurysms. Prospective radiological evaluation of five adult patients with cross-sectional imaging had failed prospectively to recognize the presence of congenital portosystemic shunts on one or more imaging examinations. Congenital portosystemic shunts are associated with splenic artery aneurysms, a previously unrecognized association. Portosystemic shunts were undetected during prospective radiologic evaluation in the majority of adult patients, highlighting the need to alert radiologists to this congenital anomaly. Copyright © 2010. Published by Elsevier Ireland Ltd.
Tension pneumocephalus following suboccipital sitting craniotomy in the pediatric population.
Daszkiewicz, P; Dziedzic, D
Sitting craniotomy often results in entrapment of air in fluid-filled intracranial cavities. Gas under pressure exerts a deleterious effect on adjacent nervous tissue, resulting in clinical deterioration. To assess the incidence of tension pneumocephalus (TP) and to define risk factors associated therewith. Analysis included 100 consecutive patients (57 boys, 43 girls, mean age 9.7 y) undergoing suboccipital sitting craniotomy since 2012 to 2014. In our material (n=100) TP was seen in 7 cases, asymptomatic pneumocephalus (AP) in 77 and no pneumocephalus (NP) in 16. Tumor types encountered were typical for pediatric population. In the TP group (n=7) the ratio of low-grade to high-grade tumors was 5:2, in the AP group (n=77) 2:1 and in the NP group (n=16) 1:1. Preoperative hydrocephalus was present in 21 cases (21%, mean incidence), thereof 3 in the TP group (3/7; 42.8%), 12 in AP group (12/77; 15.5%) and 6 in the NP group (6/16; 37.5%). All TP patients received an emergency external drainage, thereof 4 required a permanent ventriculo-peritoneal shunt (57.1%), while AP and NP patients combined (n=93) required a permanent shunt in 4 cases only (4.3%). TP-associated morbidity (n=2) consisted in a significant deterioration of neurological condition. TP is a relatively rare but potentially serious complication of suboccipital sitting craniotomy. Risk factors for TP are low-grade tumor and pre-existing long-standing hydrocephalus. TP requires emergency decompression by temporary external drainage. TP patients significantly more often require a permanent CSF shunt. Copyright © 2017. Published by Elsevier Urban & Partner Sp. z o.o.
Wan, Yue-Meng; Li, Yu-Hua; Xu, Ying; Wu, Hua-Mei; Li, Ying-Chun; Wu, Xi-Nan; Yang, Jin-Hui
2018-01-16
Transjugular intrahepatic portosystemic shunt (TIPS) is an established method for portal hypertension. This study was to investigate the long-term safety, technical success, and patency of TIPS, and to determine the risk factors and clinical impacts of shunt dysfunction. A total of 154 consecutive patients undergoing embolotherapy of gastric coronary vein and/or short gastric vein and TIPS creation were prospectively studied. Follow-up data included technical success, patency and revision of TIPS, and overall survival of patients. During the study, the primary and secondary technical success rates were 98.7% and 100%, respectively. Sixty-three patients developed shunt dysfunction, 30 with shunt stenosis and 33 with shunt occlusion. The cumulative 60-month primary, primary assisted, and secondary patency rates were 19.6%, 43.0%, and 93.4%, respectively. The cumulative 60-month overall survival rates were similar between the TIPS dysfunction group and the TIPS non-dysfunction group (68.6% vs. 58.6%, P = .096). Baseline portal vein thrombosis (P < .001), use of bare stents (P = .018), and portal pressure gradient (PPG) (P = .020) were independent predictors for shunt dysfunction, hepatocellular carcinoma (P < .001), and ascites (P = .003) for overall survival. The accuracy of PPG for shunt dysfunction was statistically significant (P < .001), and a cutoff value of 8.5 had 77.8% sensitivity and 64.8% specificity. The long-term safety, technical success, and patency of TIPS were good; baseline portal vein thrombosis, use of bare stents, and PPG were significantly associated with shunt dysfunction; shunt dysfunction has little impact on patients' long-term survival because of high secondary patency rates. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Weerakkody, R A; Czosnyka, M; Schuhmann, M U; Schmidt, E; Keong, N; Santarius, T; Pickard, J D; Czosnyka, Z
2011-08-01
The term hydrocephalus encompasses a range of disorders characterised by clinical symptoms, abnormal brain imaging and derangement of cerebrospinal fluid (CSF) dynamics. The ability to elucidate which patients would benefit from CSF diversion (a shunt or third ventriculostomy) is often unclear. Similar difficulties are often encountered in shunted patients to predict the scope for improvement by shunt re-adjustment or revision. In this study we aimed to update our knowledge of how key quantitative parameters describing CSF dynamics may be used in diagnosis of shunt-responsive hydrocephalus and in the assessment of shunt function. A number of quantitative parameters [including resistance to CSF outflow (Rcsf), pulse amplitude of intracranial pressure waveform (AMP), RAP index and slow vasogenic waves] were studies in 1423 patients with 2665 CSF infusion tests and 305 overnight intracranial pressure (ICP)-monitoring sessions over a 17 year period. We demonstrate our observations for typical values of Pb, Rcsf, AMP, slow vasogenic waves derived from infusion studies or overnight ICP monitoring in differentiating atrophy from shunt-responsive normal pressure hydrocephalus or acute hydrocephalus. From the same variables tested on shunted patients we demonstrate a standardised approach to help differentiate a properly-functioning shunt from underdrainage or overdrainage. Quantitative variables derived from CSF dynamics allow differentiation between clinically overlapping entities such as shunt-responsive normal pressure hydrocephalus and brain atrophy (not shunt responsive) as well as allowing the detection of shunt malfunction (partial or complete blockage) or overdrainage. This observational study is intended to serve as an update for our understanding of quantitative testing of CSF dynamics. © 2011 John Wiley & Sons A/S.
Bove, Edward L; Migliavacca, Francesco; de Leval, Marc R; Balossino, Rossella; Pennati, Giancarlo; Lloyd, Thomas R; Khambadkone, Sachin; Hsia, Tain-Yen; Dubini, Gabriele
2008-08-01
Stage one reconstruction (Norwood operation) for hypoplastic left heart syndrome can be performed with either a modified Blalock-Taussig shunt or a right ventricle-pulmonary artery shunt. Both methods have certain inherent characteristics. It is postulated that mathematic modeling could help elucidate these differences. Three-dimensional computer models of the Blalock-Taussig shunt and right ventricle-pulmonary artery shunt modifications of the Norwood operation were developed by using the finite volume method. Conduits of 3, 3.5, and 4 mm were used in the Blalock-Taussig shunt model, whereas conduits of 4, 5, and 6 mm were used in the right ventricle-pulmonary artery shunt model. The hydraulic nets (lumped resistances, compliances, inertances, and elastances) were identical in the 2 models. A multiscale approach was adopted to couple the 3-dimensional models with the circulation net. Computer simulations were compared with postoperative catheterization data. Good correlation was found between predicted and observed data. For the right ventricle-pulmonary artery shunt modification, there was higher aortic diastolic pressure, decreased pulmonary artery pressure, lower Qp/Qs ratio, and higher coronary perfusion pressure. Mathematic modeling predicted minimal regurgitant flow in the right ventricle-pulmonary artery shunt model, which correlated with postoperative Doppler measurements. The right ventricle-pulmonary artery shunt demonstrated lower stroke work and a higher mechanical efficiency (stroke work/total mechanical energy). The close correlation between predicted and observed data supports the use of mathematic modeling in the design and assessment of surgical procedures. The potentially damaging effects of a systemic ventriculotomy in the right ventricle-pulmonary artery shunt modification of the Norwood operation have not been analyzed.
Schenker, Pascale; Stieglitz, Lennart H; Sick, Beate; Stienen, Martin N; Regli, Luca; Sarnthein, Johannes
2018-02-01
Ventriculoperitoneal (VP) shunting is a well-established therapy for hydrocephalus. However, complications are frequent. The incidence of idiopathic normal pressure hydrocephalus (NPH) increases with the aging of the population. We evaluated the functional status of patients and the classification of complications associated with VP shunt procedures in our center. We recorded all VP shunt procedures in our prospective patient registry from January 2013 to December 2015. Functional outcome (Karnofsky Performance Status [KPS] and modified Rankin Scale) and complications were compiled from patient records. Any deviation from the normal postoperative course within 3 months after surgery was considered a complication. Complications were classified with the therapy-oriented Clavien-Dindo grading system. We evaluated potential risk factors with a logistic regression model. From 285 procedures in the reporting period, 90 were excluded, resulting in 195 patients. Among those patients, 174 (90%) were shunt implantations and 21 (11%) were shunt revisions. Forty-four shunts (23%) were implanted for NPH. Median KPS improved over the first year after surgery. Although some type of complication was observed in 114 patients (58%), 60 of those complications (31%) did not require surgical treatment (Clavien-Dindo grade <3). In 50 patients (26%), the complication concerned the shunt itself. A high KPS at admission and NPH as underlying indication significantly reduced the odds ratio for a complication. Although shunt surgery has a high general rate of complications, this rate is significantly lower for patients with NPH. The decision for shunting in patients with NPH should consider the low complication rate specific for the group of patients with NPH. Copyright © 2017 Elsevier Inc. All rights reserved.
Lee, E J; Hung, Y C; Chang, C H; Pai, M C; Chen, H H
1998-01-01
The purpose of this study was to evaluate pre- and post-shunting haemodynamic changes and their correlation with the clinical results in normal pressure hydrocephalus (NPH). Accordingly, eleven demented patients with clinical signs suggestive of NPH received examinations of cerebral blood flow velocity (BFV) and vasomotor reactivity (VMR) by transcranial Doppler sonography with carbogen testing before and after shunt treatment. Computerized tomography (CT), clinical assessment and neuropsychological grading were performed prior to and at 3 months following surgery. A control group consisting of 10 patients was included to establish baseline data. The pre-operative CBF studies in the anterior cerebral artery (ACA) and the middle cerebral artery (MCA) revealed the NPH patients did not have significant decreases of BFVs, but had significant decreases of carbogen VMR (P < 0.05). After shunting, there were no significant changes of the BFVs as compared with the pre-shunting data. The post-shunting VMR of the ACA was significantly higher than the pre-shunting one (p < 0.05), but there was no variation in that of the MCA. Both the values of post-shunting VMR in ACA and the post-shunting increase in VMR in MCA of the 7 shunt-responsive patients who improved mentally and in other symptoms were significantly higher than those of patients without improvement (p < 0.05). In addition, the five patients with gait improvement showed significantly higher values of post-shunting VMR of ACA and the post-shunting increase of VMR for both ACA and MCA when compared with those patients without gait improvement (p < 0.05, respectively). Our study supports the view that patients with NPH had various degrees of impaired VMR in both the ACA and the MCA, but showed insignificant reduction in BFVs, indicating a compensatory mechanism of CBF over time to accommodate the subnormal state of cerebral perfusion pressure. Shunt placement would improve the VMR in responsive patients. Postoperatively, an increase of VMR tends to accompany improvement of the functional state: that in the MCA alone is associated with symptomatic improvement in mental function and that increase in VMR in both the ACA and the MCA with improvement in gait, respectively.
Power Quality Improvement Using an Enhanced Network-Side-Shunt-Connected Dynamic Voltage Restorer
NASA Astrophysics Data System (ADS)
Fereidouni, Alireza; Masoum, Mohammad A. S.; Moghbel, Moayed
2015-10-01
Among the four basic dynamic voltage restorer (DVR) topologies, the network-side shunt-connected DVR (NSSC-DVR) has a relatively poor performance and is investigated in this paper. A new configuration is proposed and implemented for NSSC-DVR to enhance its performance in compensating (un)symmetrical deep and long voltage sags and mitigate voltage harmonics. The enhanced NSSC-DVR model includes a three-phase half-bridge semi-controlled network-side-shunt-connected rectifier and a three-phase full-bridge series-connected inverter implemented with a back-to-back configuration through a bidirectional buck-boost converter. The network-side-shunt-connected rectifier is employed to inject/draw the required energy by NSSC-DVR to restore the load voltage to its pre-fault value under sag/swell conditions. The buck-boost converter is responsible for maintaining the DC-link voltage of the series-connected inverter at its designated value in order to improve the NSSC-DVR capability in compensating deep and long voltage sags/swells. The full-bridge series-connected inverter permits to compensate unbalance voltage sags containing zero-sequence component. The harmonic compensation of the load voltage is achieved by extracting harmonics from the distorted network voltage using an artificial neural network (ANN) method called adaptive linear neuron (Adaline) strategy. Detailed simulations are performed by SIMULINK/MATLAB software for six case studies to verify the highly robustness of the proposed NSSC-DVR model under various conditions.
van Steenbeek, Frank G; van den Bossche, Lindsay; Leegwater, Peter A J; Rothuizen, Jan
2012-02-01
Congenital disorders of the hepatic portal vasculature are rare in man but occur frequently in certain dog breeds. In dogs, there are two main subtypes: intrahepatic portosystemic shunts, which are considered to stem from defective closure of the embryonic ductus venosus, and extrahepatic shunts, which connect the splanchnic vascular system with the vena cava or vena azygos. Both subtypes result in nearly complete bypass of the liver by the portal blood flow. In both subtypes the development of the smaller branches of the portal vein tree in the liver is impaired and terminal branches delivering portal blood to the liver lobules are often lacking. The clinical signs are due to poor liver growth, development, and function. Patency of the ductus venosus seems to be a digenic trait in Irish wolfhounds, whereas Cairn terriers with extrahepatic portosystemic shunts display a more complex inheritance. The genes involved in these disorders cannot be identified with the sporadic human cases, but in dogs, the genome-wide study of the extrahepatic form is at an advanced stage. The canine disease may lead to the identification of novel genes and pathways cooperating in growth and development of the hepatic portal vein tree. The same pathways likely regulate the development of the vascular system of regenerating livers during liver diseases such as hepatitis and cirrhosis. Therefore, the identification of these molecular pathways may provide a basis for future proregenerative intervention.
Drainage of malignant ascites: patient selection and perspectives
Stukan, Maciej
2017-01-01
Malignant ascites (MA) is a sign of advanced cancer and poor prognosis. MA can result in impairment in quality of life (QOL) and significant symptoms. As a supportive treatment, ascites can be drained by paracentesis (PC), percutaneously implanted catheters (tunneled, untunneled, central venous catheters), or peritoneal ports, or peritoneovenous shunts. The aim of this study was to evaluate the effectiveness, safety, and patient-reported outcomes (PRO) of different drainage methods for the management of MA. A systematic review of the literature was performed, and 32 original articles met the inclusion criteria. Patients selected for permanent drain insertion demonstrated symptoms related to MA and had undergone repeated PC. The primary focus of the reviewed articles was procedural safety issues. The rate of technical success of drainage device installation was 100%. Most patients experienced improvements in symptom control after ascites drainage. When analyzed together, 19.7% (255/1297) of patients experienced any complication and 6.2% (81/1297) experienced serious adverse events during MA drainage. Complications were reported for every drainage method; however, the least occurred after PC or central venous catheter, while the most serious occurred after peritoneovenous shunts. Adverse events were as follows: catheter obstruction: 4.4%, infection: 4.1%, leakage: 3.5%, catheter dislodgment: 2.3%, hypotension: 0.6%, injuries during device insertion: 0.6%, renal impairment: 0.5%, electrolyte imbalance: 0.2%, other: 3.6%. PRO and QOL endpoints were available for 12 studies. When PRO were measured using an interview, a significant improvement in symptom control and QOL was reported in almost all patients. Once standardized questionnaires were used, improvements in symptomatic scores and role functioning were observed. Deterioration was observed in cognitive and emotional subscales. MA drainage is a safe and effective method to control symptoms associated with ascites, and should be perceived as a supportive care, that can be applied for those who need it at any time of their cancer trajectory. Patient selection should be performed using a thorough assessment of symptoms and QOL, and should not be delayed. PMID:28442933
Bohl, Michael A; Xu, David S; Cavallo, Claudio; Paisan, Gabriella M; Smith, Kris A; Nakaji, Peter
2018-06-01
The Barrow Innovation Center consists of an educational program that promotes interdisciplinary collaboration among neurosurgery, legal, and engineering professionals to foster the development of new medical devices. This report describes a common issue faced during the placement of ventricular shunts for the treatment of hydrocephalus, and the solution to this problem that was developed through the Barrow Innovation Center. Neurosurgery residents involved in the Barrow Innovation Center presented the problem of ferromagnetic retractors interfering with pinless image-guidance systems at a monthly meeting. Potential solutions were openly discussed by an interdisciplinary committee of neurosurgeons, patent lawyers, and biomedical engineers. The committee decided to pursue development of a novel self-retaining retractor made of non-ferromagnetic material as a solution to the problem. Each retractor design was tested in the cadaver laboratory for size and functionality. A final design was chosen and used in a surgical case requiring ventriculoperitoneal shunt placement. The new retractor successfully retracted the scalp without interfering with the electromagnetic image-guidance system. Through the interdisciplinary Barrow Innovation Center program, a newly designed, 3-dimensional-printed skin and soft tissue retractor was created, along with an innovative universal shunt retainer. Through this integrated program dedicated to surgical innovation (i.e., the Barrow Innovation Center), the process of developing and implementing new technology at our institution has been streamlined, creating a culture of innovation within the neurosurgery training program. Copyright © 2018 Elsevier Inc. All rights reserved.