Sample records for siemens erlangen germany

  1. White Matter Hyperintensities and Hypobaric Exposure

    DTIC Science & Technology

    2014-11-01

    at the Research Imaging Institute, University of Texas Health Science Center, San Antonio, Texas , using a Siemens (Erlangen, Germany) 3T Tim Trio... Research Department 2510 Fifth St. Wright-Patterson AFB, OH 45433-7913 8. PERFORMING ORGANIZATION REPORT NUMBER AFRL-SA-WP-JA-2014-0008...Prescribed by ANSI Std. Z39.18 RESEARCH ARTICLE White Matter Hyperintensities and Hypobaric Exposure Stephen A. McGuire, MD,1,2,3 Paul M

  2. Comparison of Two Different Ultrasound Devices Using Strain Elastography Technology in the Diagnosis of Breast Lesions Related to the Histologic Results.

    PubMed

    Farrokh, André; Schaefer, Fritz; Degenhardt, Friedrich; Maass, Nicolai

    2018-05-01

    This study was conducted to provide evidence that elastograms of two different devices and different manufacturers using the same technical approach provide the same diagnoses. A total of 110 breast lesions were prospectively analysed by two experts in ultrasound, using the strain elastography function from two different manufacturers (Hitachi HI-RTE, Hitachi Medical Systems, Wiesbaden, Germany; and Siemens eSie Touch, Siemens Medical Systems, Erlangen, Germany). Results were compared with the histopathologic results. Applying the Bowker test of symmetry, no statistically significant difference between the two elastography functions of these two devices was found (p = 0.120). The Cohen's kappa of k = 0.591 showed moderate strength of agreement between the two elastograms. The two examiners yielded moderate strength of agreement analysing the elastograms (Hitachi HI-RTE, k = 0.478; Siemens eSie Touch, k = 0.441). In conclusion, evidence is provided that elastograms of the same lesion generated by two different ultrasound devices equipped with a strain elastography function do not significantly differ. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  3. Contrast-Enhanced Ultrasound as a New Investigative Tool in Diagnostic Imaging of Muscle Injuries-A Pilot Study Evaluating Conventional Ultrasound, CEUS, and Findings in MRI.

    PubMed

    Hotfiel, Thilo; Heiss, Rafael; Swoboda, Bernd; Kellermann, Marion; Gelse, Kolja; Grim, Casper; Strobel, Deike; Wildner, Dane

    2018-07-01

    To emphasize the diagnostic value of contrast-enhanced ultrasound (CEUS) in the imaging of muscle injuries with different degrees of severity by comparing findings to established imaging modalities such as conventional ultrasound and magnetic resonance imaging (MRI). Case series. Institutional study. Conventional ultrasound and CEUS were performed in the Department of Internal Medicine. Magnetic resonance imaging was carried out in the Department of Radiology within the Magnetom Avanto 1.5T and Magnetom Skyra fit 3T (Siemens Healthineers, Erlangen, Germany) and in the Institution of Imaging Diagnostics and Therapy (Magnetom Avanto 1.5T; Siemens, Erlangen, Germany). Fifteen patients who underwent an acute muscle injury were recruited. The appearance and detectable size of muscle injuries were compared between each imaging modality. The injuries were assessed by 3 independent observers and blinded between imaging modalities. All 15 injuries were identified on MRI and CEUS, whereas 10 injuries showed abnormalities in conventional ultrasound. The determination and measurement revealed significant differences between conventional ultrasound and CEUS depending on injury severity. Contrast-enhanced ultrasound revealed an impairment of microcirculation in grade I lesions (corresponding to intramuscular edema observed in MRI), which was not detectable using conventional ultrasound. Our results indicate that performing CEUS seems to be a sensitive additional diagnostic modality in the early assessment of muscle injuries. Our results highlight the advantages of CEUS in the imaging of low-grade lesions when compared with conventional ultrasound, as this was the more accurate modality for identifying intramuscular edema.

  4. Germany plans 60m euro physics and medicine lab

    NASA Astrophysics Data System (ADS)

    Stafford, Ned

    2017-09-01

    A new €60m medical-physics research lab is to be built in Erlangen, Germany, by the Max Planck Institute for the Science of Light (MPL) together with the Friedrich Alexander University Erlangen-Nürnberg and the University Hospital Erlangen.

  5. Development and validation of a BEAMnrc component module for a miniature multileaf collimator.

    PubMed

    Doerner, E; Hartmann, G H

    2012-05-21

    A new component module (CM) named mini multileaf collimator (mMLC) was developed for the Monte Carlo code BEAMnrc. It models the geometry of the add-on miniature multileaf collimator ModuLeaf (MRC Systems GmbH, Heidelberg, Germany, now part of Siemens, Erlangen, Germany). The new CM is partly based on the existing CM called DYNVMLC. The development was performed using a modified EGSnrc platform which enables us to work in the Microsoft Visual Studio environment. In order to validate the new CM, the PRIMUS linac with 6 MV x-rays (Siemens OCS, Concord, CA, USA) equipped with the ModuLeaf mMLC was modelled. Validation was performed by two methods: (a) a ray-tracing method to check the correct geometry of the multileaf collimator (MLC) and (b) a comparison of calculated and measured results of the following dosimetrical parameters: output factors, dose profiles, field edge position penumbra, MLC interleaf leakage and transmission values. Excellent agreement was found for all parameters. It was, in particular, found that the relationship between leaf position and field edge depending on the shape of the leaf ends can be investigated with a higher accuracy by this new CM than by measurements demonstrating the usefulness of the new CM.

  6. Development and validation of a BEAMnrc component module for a miniature multileaf collimator

    NASA Astrophysics Data System (ADS)

    Doerner, E.; Hartmann, G. H.

    2012-05-01

    A new component module (CM) named mini multileaf collimator (mMLC) was developed for the Monte Carlo code BEAMnrc. It models the geometry of the add-on miniature multileaf collimator ModuLeaf (MRC Systems GmbH, Heidelberg, Germany, now part of Siemens, Erlangen, Germany). The new CM is partly based on the existing CM called DYNVMLC. The development was performed using a modified EGSnrc platform which enables us to work in the Microsoft Visual Studio environment. In order to validate the new CM, the PRIMUS linac with 6 MV x-rays (Siemens OCS, Concord, CA, USA) equipped with the ModuLeaf mMLC was modelled. Validation was performed by two methods: (a) a ray-tracing method to check the correct geometry of the multileaf collimator (MLC) and (b) a comparison of calculated and measured results of the following dosimetrical parameters: output factors, dose profiles, field edge position penumbra, MLC interleaf leakage and transmission values. Excellent agreement was found for all parameters. It was, in particular, found that the relationship between leaf position and field edge depending on the shape of the leaf ends can be investigated with a higher accuracy by this new CM than by measurements demonstrating the usefulness of the new CM.

  7. Biomedical technology in Franconia.

    PubMed

    Efferth, T

    2000-01-01

    Medical instrumentation and biotechnology business is developing rapidly in Franconia. The universities of Bayreuth, Erlangen-Nürnberg, and Würzburg hold upper ranks in biomedical extramural funding research. They have a high competence in biomedical research, medical instrumentation, and biotechnology. The association "BioMedTec Franken e.V" has been founded at the beginning of 1999 both to foster the information exchange between universities, industry and politics and to facilitate the establishment of biomedical companies by means of science parks. In the IGZ (Innovation and Foundation Center Nürnberg-Fürth-Erlangen) 4,500 square meters of space are currently shared by 19 novel companies. Since 1985 60 companies in the IGZ had a total turnover of about 74 Mio Euro. The TGZ (Technologie- und Gründerzentrum) in Würzburg provides space for 11 companies. For the specific needs of biomedical technology companies further science parks will be set up in the near future. A science park for medical instrumentation will be founded in Erlangen (IZMP, Innovations- und Gründerzentrum für Medizintechnik und Pharma in der Region Nürnberg, Fürch, Erlangen). Furthermore, a Biomedical Technology Center and a Research Center for Bicompatible Materials are to be founded in Würzburg and Bayreuth, respectively. Several communication platforms (Bayern Innovativ, FORWISS, FTT, KIM, N-TEC-VISIT, TBU, WETTI etc.) allow the transfer of local academic research activities to industrial utilization and open new co-operation possibilities. International pharmaceutical companies (Novartis, Nürnberg; Pharmacia Upjohn, Erlangen) are located in Franconia. Central Franconia represents a national focus for medical instrumentation. The Erlangen settlement of the Medical Engineering Section of Siemens employs 4,500 people including approximately 1,000 employees in the Siemens research center.

  8. Morphometric analysis - Cone beam computed tomography to predict bone quality and quantity.

    PubMed

    Hohlweg-Majert, B; Metzger, M C; Kummer, T; Schulze, D

    2011-07-01

    Modified quantitative computed tomography is a method used to predict bone quality and quantify the bone mass of the jaw. The aim of this study was to determine whether bone quantity or quality was detected by cone beam computed tomography (CBCT) combined with image analysis. MATERIALS AND PROCEDURES: Different measurements recorded on two phantoms (Siemens phantom, Comac phantom) were evaluated on images taken with the Somatom VolumeZoom (Siemens Medical Solutions, Erlangen, Germany) and the NewTom 9000 (NIM s.r.l., Verona, Italy) in order to calculate a calibration curve. The spatial relationships of six sample cylinders and the repositioning from four pig skull halves relative to adjacent defined anatomical structures were assessed by means of three-dimensional visualization software. The calibration curves for computer tomography (CT) and cone beam computer tomography (CBCT) using the Siemens phantom showed linear correlation in both modalities between the Hounsfield Units (HU) and bone morphology. A correction factor for CBCT was calculated. Exact information about the micromorphology of the bone cylinders was only available using of micro computer tomography. Cone-beam computer tomography is a suitable choice for analysing bone mass, but, it does not give any information about bone quality. 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Intraoperative magnetic resonance imaging to update interactive navigation in neurosurgery: method and preliminary experience.

    PubMed

    Wirtz, C R; Bonsanto, M M; Knauth, M; Tronnier, V M; Albert, F K; Staubert, A; Kunze, S

    1997-01-01

    We report on the first successful intraoperative update of interactive image guidance based on an intraoperatively acquired magnetic resonance imaging (MRI) date set. To date, intraoperative imaging methods such as ultrasound, computerized tomography (CT), or MRI have not been successfully used to update interactive navigation. We developed a method of imaging patients intraoperatively with the surgical field exposed in an MRI scanner (Magnetom Open; Siemens Corp., Erlangen, Germany). In 12 patients, intraoperatively acquired 3D data sets were used for successful recalibration of neuronavigation, accounting for any anatomical changes caused by surgical manipulations. The MKM Microscope (Zeiss Corp., Oberkochen, Germany) was used as navigational system. With implantable fiducial markers, an accuracy of 0.84 +/- 0.4 mm for intraoperative reregistration was achieved. Residual tumor detected on MRI was consequently resected using navigation with the intraoperative data. No adverse effects were observed from intraoperative imaging or the use of navigation with intraoperative images, demonstrating the feasibility of recalibrating navigation with intraoperative MRI.

  10. Whole Brain Networks for Treatment for Epilepsy

    DTIC Science & Technology

    2012-07-01

    target. For the numerical approach, we applied both a simultaneous over- relaxation method (e.g. Gauss - Seidel ) and a biconjugate gradient...with b=1000sec/mm 2 and 7 b=0 acquisitions) was acquired on a Siemens TIM Trio (Siemens Medical Solutions, Erlangen) followed by iterative motion...partly from the difficulty with which the Monte Carlo approach is able to determine track densities at regions distal to the seed. Much iteration is

  11. A Review of Fatigue Crack Growth of Pressure Vessel and Piping Steels in High-Temperature, Pressurized Reactor-Grade Water.

    DTIC Science & Technology

    1980-09-19

    ratio, irradiation, materials Germany Kraftwerk Union Materials, temperature, Erlangen, Germany load ratio, frequency, electro- chemical potential Italy...H. Munster, "Frequenzeinfluss auf das Risswachstumsverhalten des Stahles 22NiMoCr37", KWU/R 413/8/80, Kraftwerk Union, Erlangen (1980). 76. D. F

  12. MR-monitored LITT as a palliative concept in patients with high grade gliomas: preliminary clinical experience.

    PubMed

    Reimer, P; Bremer, C; Horch, C; Morgenroth, C; Allkemper, T; Schuierer, G

    1998-01-01

    The purpose of this study was to evaluate the clinical utility of laser-induced thermotherapy (LITT) as a palliative treatment for patients with high-grade gliomas. Four consenting patients with recurrent high grade III/IV gliomas near the primary language or motor areas were palliatively treated with LITT (2-5 W, 3-13 minutes; Neodym YAG Laser, Dornier, Friedrichshafen, Germany). Temperature monitoring was performed by T1-weighted turbo-fast low-angle shot (FLASH) imaging at 1.5 T (Siemens Magnetom SP 4000, Siemens, Erlangen, Germany). MRI studies before LITT included contrast-enhanced conventional scans and functional activation studies to localize the primary motor cortex or language areas using an echo-planar imaging (EPI) spin-echo (SE) sequence. Follow-up studies consisted of contrast-enhanced conventional scans as well as diffusion studies (contrast-enhanced Fourier-acquired steady-state technique and EPI-SE) and perfusion studies (EPI-SE with .2 mmol of gadolinium (Gd)/kg body weight) to differentiate post-therapeutic effects from residual or recurrent tumor growth. Local tumor control was achieved in areas with laser energy deposition with clinically stable conditions > or = 6 months. Conventional contrast-enhanced scans demonstrated strong enhancement surrounding ablated tumor components, which showed a reduction in CBV/CBF. Perfusion studies were useful to discriminate granulomatous tissue enhancement from residual or recurrent tumor growth. Careful application of LITT may evolve as an alternative palliative concept for patients with end-stage high-grade cerebral gliomas reducing clinical symptoms from circumscribed areas of pathology.

  13. Food-related odor probes of brain reward circuits during hunger: a pilot FMRI study.

    PubMed

    Bragulat, Veronique; Dzemidzic, Mario; Bruno, Carolina; Cox, Cari A; Talavage, Thomas; Considine, Robert V; Kareken, David A

    2010-08-01

    Food aromas can be powerful appetitive cues in the natural environment. Although several studies have examined the cerebral responses to food images, none have used naturalistic food aromas to study obesity. Ten individuals (five normal-weight and five obese) were recruited to undergo 24 h of food deprivation. Subjects were then imaged on a 3T Siemens Trio-Tim scanner (Siemens, Erlangen, Germany) while smelling four food-related odors (FRO; two sweet odors and two fat-related) and four "nonappetitive odors" (NApO; e.g., Douglas fir). Before the imaging session, subjects rated their desire to eat each type of food to determine their most preferred (P-FRO). Across all 10 subjects, P-FRO elicited a greater blood oxygenation level dependent (BOLD) response than the NApO in limbic and reward-related areas, including the bilateral insula and opercular (gustatory) cortex, the anterior and posterior cingulate, and ventral striatum. Obese subjects showed greater activation in the bilateral hippocampus/parahippocampal gyrus, but lean controls showed more activation in the posterior insula. Brain areas activated by food odors are similar to those elicited by cues of addictive substances, such as alcohol. Food odors are highly naturalistic stimuli, and may be effective probes of reward-related networks in the context of hunger and obesity.

  14. Stress Computed Tomography Myocardial Perfusion Imaging: A New Topic in Cardiology.

    PubMed

    Seitun, Sara; Castiglione Morelli, Margherita; Budaj, Irilda; Boccalini, Sara; Galletto Pregliasco, Athena; Valbusa, Alberto; Cademartiri, Filippo; Ferro, Carlo

    2016-02-01

    Since its introduction about 15 years ago, coronary computed tomography angiography has become today the most accurate clinical instrument for noninvasive assessment of coronary atherosclerosis. Important technical developments have led to a continuous stream of new clinical applications together with a significant reduction in radiation dose exposure. Latest generation computed tomography scanners (≥ 64 slices) allow the possibility of performing static or dynamic perfusion imaging during stress by using coronary vasodilator agents (adenosine, dipyridamole, or regadenoson), combining both functional and anatomical information in the same examination. In this article, the emerging role and state-of-the-art of myocardial computed tomography perfusion imaging are reviewed and are illustrated by clinical cases from our experience with a second-generation dual-source 128-slice scanner (Somatom Definition Flash, Siemens; Erlangen, Germany). Technical aspects, data analysis, diagnostic accuracy, radiation dose and future prospects are reviewed. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  15. Clinical utility of automated assessment of left ventricular ejection fraction using artificial intelligence-assisted border detection.

    PubMed

    Rahmouni, Hind W; Ky, Bonnie; Plappert, Ted; Duffy, Kevin; Wiegers, Susan E; Ferrari, Victor A; Keane, Martin G; Kirkpatrick, James N; Silvestry, Frank E; St John Sutton, Martin

    2008-03-01

    Ejection fraction (EF) calculated from 2-dimensional echocardiography provides important prognostic and therapeutic information in patients with heart disease. However, quantification of EF requires planimetry and is time-consuming. As a result, visual assessment is frequently used but is subjective and requires extensive experience. New computer software to assess EF automatically is now available and could be used routinely in busy digital laboratories (>15,000 studies per year) and in core laboratories running large clinical trials. We tested Siemens AutoEF software (Siemens Medical Solutions, Erlangen, Germany) to determine whether it correlated with visual estimates of EF, manual planimetry, and cardiac magnetic resonance (CMR). Siemens AutoEF is based on learned patterns and artificial intelligence. An expert and a novice reader assessed EF visually by reviewing transthoracic echocardiograms from consecutive patients. An experienced sonographer quantified EF in all studies using Simpson's method of disks. AutoEF results were compared to CMR. Ninety-two echocardiograms were analyzed. Visual assessment by the expert (R = 0.86) and the novice reader (R = 0.80) correlated more closely with manual planimetry using Simpson's method than did AutoEF (R = 0.64). The correlation between AutoEF and CMR was 0.63, 0.28, and 0.51 for EF, end-diastolic and end-systolic volumes, respectively. The discrepancies in EF estimates between AutoEF and manual tracing using Simpson's method and between AutoEF and CMR preclude routine clinical use of AutoEF until it has been validated in a number of large, busy echocardiographic laboratories. Visual assessment of EF, with its strong correlation with quantitative EF, underscores its continued clinical utility.

  16. [Medical Treatment of Newly Arrived Refugees in Erlangen: A Study of Drug Prescription Rates Focused on Psychotropic Drugs].

    PubMed

    Kahl, Fabian; Frewer, Andreas

    2017-04-01

    Background: In 2015 the number of refugees who sought asylum in Germany has increased dramatically. Therefore, the medical care for these refugees faces huge challenges. The treatment of mental illness of refugees is a particular difficult topic. Objective of this study is the acquisition of the outpatient prescriptions of drugs for newly arrived refugees in Erlangen, focused on psychotropic drugs. Methods: Evaluation of all outpatient prescribed drugs (n=1 137), which were prescribed between 10/01/2014 and 09/30/2015 for asylum seekers living in the refugee center in Erlangen, a branch of the "Central Admission Institution" ("ZAE") Zirndorf. Funding organization of this treatment is the City of Erlangen. Settlement documents of the City of Erlangen were used for the analysis. Results: The prescribed drugs cover the spectrum of acute primary care. Big parts of the prescription rates are antiinfectives (ATC-Code: J), medication for the respiratory system (ATC: R), as well as non-steroidal anti-inflammatory drug (NSAID's: ibuprofen, paracetamol, metamizole). The prescription of psychotropic drugs is relatively underrepresented. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Comparison of different approaches of estimating effective dose from reported exposure data in 3D imaging with interventional fluoroscopy systems

    NASA Astrophysics Data System (ADS)

    Svalkvist, Angelica; Hansson, Jonny; Bâth, Magnus

    2014-03-01

    Three-dimensional (3D) imaging with interventional fluoroscopy systems is today a common examination. The examination includes acquisition of two-dimensional projection images, used to reconstruct section images of the patient. The aim of the present study was to investigate the difference in resulting effective dose obtained using different levels of complexity in calculations of effective doses from these examinations. In the study the Siemens Artis Zeego interventional fluoroscopy system (Siemens Medical Solutions, Erlangen, Germany) was used. Images of anthropomorphic chest and pelvis phantoms were acquired. The exposure values obtained were used to calculate the resulting effective doses from the examinations, using the computer software PCXMC (STUK, Helsinki, Finland). The dose calculations were performed using three different methods: 1. using individual exposure values for each projection image, 2. using the mean tube voltage and the total DAP value, evenly distributed over the projection images, and 3. using the mean kV and the total DAP value, evenly distributed over smaller selection of projection images. The results revealed that the difference in resulting effective dose between the first two methods was smaller than 5%. When only a selection of projection images were used in the dose calculations the difference increased to over 10%. Given the uncertainties associated with the effective dose concept, the results indicate that dose calculations based on average exposure values distributed over a smaller selection of projection angles can provide reasonably accurate estimations of the radiation doses from 3D imaging using interventional fluoroscopy systems.

  18. 76 FR 58768 - Ball Bearings and Parts Thereof From France, Germany, and Italy; Amended Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-22

    ... determined for this company continues to be 5.47 percent. Germany: ``BSH Bosch and Siemens Hausgerate GmbH'' has been changed to ``BSH Bosch und Siemens Hausgerate GmbH;'' ``Volkswagon AG'' has been changed to...

  19. Comparison of an oscillometric method with cardiac magnetic resonance for the analysis of aortic pulse wave velocity.

    PubMed

    Feistritzer, Hans-Josef; Reinstadler, Sebastian J; Klug, Gert; Kremser, Christian; Seidner, Benjamin; Esterhammer, Regina; Schocke, Michael F; Franz, Wolfgang-Michael; Metzler, Bernhard

    2015-01-01

    Pulse wave velocity (PWV) is the proposed gold-standard for the assessment of aortic elastic properties. The aim of this study was to compare aortic PWV determined by a recently developed oscillometric device with cardiac magnetic resonance imaging (CMR). PWV was assessed in 40 volunteers with two different methods. The oscillometric method (PWVOSC) is based on a transfer function from the brachial pressure waves determined by oscillometric blood pressure measurements with a common cuff (Mobil-O-Graph, I.E.M. Stolberg, Germany). CMR was used to determine aortic PWVCMR with the use of the transit time method based on phase-contrast imaging at the level of the ascending and abdominal aorta on a clinical 1.5 Tesla scanner (Siemens, Erlangen, Germany). The median age of the study population was 34 years (IQR: 24-55 years, 11 females). A very strong correlation was found between PWVOSC and PWVCMR (r = 0.859, p < 0.001). Mean PWVOSC was 6.7 ± 1.8 m/s and mean PWVCMR was 6.1 ± 1.8 m/s (p < 0.001). Analysis of agreement between the two measurements using Bland-Altman method showed a bias of 0.57 m/s (upper and lower limit of agreement: 2.49 m/s and -1.34 m/s). The corresponding coefficient of variation between both measurements was 15%. Aortic pulse wave velocity assessed by transformation of the brachial pressure waveform showed an acceptable agreement with the CMR-derived transit time method.

  20. Measurements of the trapezius and erector spinae muscles using virtual touch imaging quantification ultrasound-Elastography: a cross section study.

    PubMed

    Heizelmann, Anne; Tasdemir, Sümeyra; Schmidberger, Julian; Gräter, Tilmann; Kratzer, Wolfgang; Grüner, Beate

    2017-08-25

    This study uses virtual touch imaging quantification (VTIQ) technology for the first time to conduct measurements of the trapezius and erector spinae muscles in a large study population. The significance of various influencing factors, such as age and sex, are also examined. The study population comprised 278 subjects. The Siemens Acuson S3000 and VTIQ technology were used for measurements of the trapezius and erector spinae muscles (Siemens Healthcare, Erlangen, Germany). The following mean values ± standard deviation were calculated: left trapezius: males 2.89 ± 0.38 m/s, females 2.71 ± 0.37 m/s; right trapezius: males 2.84 ± 0.41 m/s, females 2.70 ± 0.38 m/s; left erector spinae: males 2.97 ± 0.50 m/s, females 2.81 ± 0.57 m/s; right erector spinae: males 3.00 ± 0.52 m/s, females 2.77 ± 0.59 m/s. A significant difference between male and female subjects was demonstrated both for the shear wave velocities of the trapezius and erector spinae as well as for the thickness of the trapezius muscle (p < 0.05). There was also a significant difference in muscle elasticity between subjects over 60 years of age and those under 60 (p < 0.05). Furthermore, the results indicate that regular physical activity has an effect on muscle elasticity. Our results demonstrate significantly different results between male and female subjects and between under- and over-sixty-year-old subjects. This means that sex-related and age-adapted considerations are obviously needed for further studies.

  1. Magnetic Resonance Imaging-Guided Osseous Biopsy in Children With Chronic Recurrent Multifocal Osteomyelitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fritz, Jan, E-mail: jfritz9@jhmi.edu; Tzaribachev, Nikolay; Thomas, Christoph

    2012-02-15

    Purpose: To report the safety and diagnostic performance of magnetic resonance (MRI)-guided core biopsy of osseous lesions in children with chronic recurrent multifocal osteomyelitis (CRMO) that were visible on MRI but were occult on radiography and computed tomography (CT). Materials and Methods: A retrospective analysis of MRI-guided osseous biopsy performed in seven children (four girls and three boys; mean age 13 years (range 11 to 14) with CRMO was performed. Indication for using MRI guidance was visibility of lesions by MRI only. MRI-guided procedures were performed with 0.2-Tesla (Magnetom Concerto; Siemens, Erlangen, Germany; n = 5) or 1.5-T (Magnetom Espree;more » Siemens; n = 2) open MRI systems. Core needle biopsy was obtained using an MRI-compatible 4-mm drill system. Conscious sedation or general anesthesia was used. Parameters evaluated were lesion visibility, technical success, procedure time, complications and microbiology, cytology, and histopathology findings. Results: Seven of seven (100%) targeted lesions were successfully visualized and sampled. All obtained specimens were sufficient for histopathological analysis. Length of time of the procedures was 77 min (range 64 to 107). No complications occurred. Histopathology showed no evidence of malignancy, which was confirmed at mean follow-up of 50 months (range 28 to 78). Chronic nonspecific inflammation characteristic for CRMO was present in four of seven (58%) patients, and edema with no inflammatory cells was found in three of seven (42%) patients. There was no evidence of infection in any patient. Conclusion: MRI-guided osseous biopsy is a safe and accurate technique for the diagnosis of pediatric CRMO lesions that are visible on MRI only.« less

  2. Optimized 14 + 1 receive coil array and position system for 3D high-resolution MRI of dental and maxillomandibular structures.

    PubMed

    Sedlacik, Jan; Kutzner, Daniel; Khokale, Arun; Schulze, Dirk; Fiehler, Jens; Celik, Turgay; Gareis, Daniel; Smeets, Ralf; Friedrich, Reinhard E; Heiland, Max; Assaf, Alexandre T

    2016-01-01

    The purpose of this study was to design, build and test a multielement receive coil array and position system, which is optimized for three-dimensional (3D) high-resolution dental and maxillomandibular MRI with high patient comfort. A 14 + 1 coil array and positioning system, allowing easy handling by the technologists, reproducible positioning of the patients and high patient comfort, was tested with three healthy volunteers using a 3.0-T MRI machine (Siemens Skyra; Siemens Medical Solutions, Erlangen, Germany). High-resolution 3D T1 weighted, water excitation T1 weighted and fat-saturated T2 weighted imaging sequences were scanned, and 3D image data were reformatted in different orientations and curvatures to aid diagnosis. The high number of receiving coils and the comfortable positioning of the coil array close to the patient's face provided a high signal-to-noise ratio and allowed high quality, high resolution, 3D image data to be acquired within reasonable scan times owing to the possibility of parallel image acquisition acceleration. Reformatting the isotropic 3D image data in different views is helpful for diagnosis, e.g. panoramic reconstruction. The visibility of soft tissues such as the mandibular canal, nutritive canals and periodontal ligaments was exquisite. The optimized MRI receive coil array and positioning system for dental and oral-maxillofacial imaging provides a valuable tool for detecting and diagnosing pathologies in dental and oral-maxillofacial structures while avoiding radiation dose. The high patient comfort, as achieved by our design, is very crucial, since image artefacts due to movement or failing to complete the examination jeopardize the diagnostic value of MRI examinations.

  3. Application of newly developed Fluoro-QC software for image quality evaluation in cardiac X-ray systems.

    PubMed

    Oliveira, M; Lopez, G; Geambastiani, P; Ubeda, C

    2018-05-01

    A quality assurance (QA) program is a valuable tool for the continuous production of optimal quality images. The aim of this paper is to assess a newly developed automatic computer software for image quality (IR) evaluation in fluoroscopy X-ray systems. Test object images were acquired using one fluoroscopy system, Siemens Axiom Artis model (Siemens AG, Medical Solutions Erlangen, Germany). The software was developed as an ImageJ plugin. Two image quality parameters were assessed: high-contrast spatial resolution (HCSR) and signal-to-noise ratio (SNR). The time between manual and automatic image quality assessment procedures were compared. The paired t-test was used to assess the data. p Values of less than 0.05 were considered significant. The Fluoro-QC software generated faster IQ evaluation results (mean = 0.31 ± 0.08 min) than manual procedure (mean = 4.68 ± 0.09 min). The mean difference between techniques was 4.36 min. Discrepancies were identified in the region of interest (ROI) areas drawn manually with evidence of user dependence. The new software presented the results of two tests (HCSR = 3.06, SNR = 5.17) and also collected information from the DICOM header. Significant differences were not identified between manual and automatic measures of SNR (p value = 0.22) and HCRS (p value = 0.46). The Fluoro-QC software is a feasible, fast and free to use method for evaluating imaging quality parameters on fluoroscopy systems. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  4. Correlation of pull-out strength of cement-augmented pedicle screws with CT-volumetric measurement of cement.

    PubMed

    Fölsch, Christian; Goost, Hans; Figiel, Jens; Paletta, Jürgen R J; Schultz, Wolfgang; Lakemeier, Stefan

    2012-12-01

    Cement augmentation of pedicle screws increases fixation strength in an osteoporotic spine. This study was designed to determine the cement distribution and the correlation between the pull-out strength of the augmented screw and the cement volume within polyurethane (PU) foam. Twenty-eight cannulated pedicle screws (6×45 mm) (Peter Brehm, Erlangen, Germany) with four holes at the distal end of the screw were augmented with the acrylic Stabilit ER Bone Cement Vertebral Augmentation System (DFine Inc., San Jose, CA, USA) and implanted into open-cell rigid PU foam (Pacific Research Laboratories, Vashon Island, WA, USA) with a density of 0.12 g/cm3, resembling severe osteoporosis. Volumetric measurement of the cement with consideration of the distribution around the screws was done with multislice computed tomography scan (Somatom Definition, Siemens, Erlangen, Germany). Pull-out strength was tested with a servohydraulic system (MTS System Corporation, Eden Prairie, MN, USA), and nonaugmented screws served as control. Pearson's correlation coefficient with significance level α=0.05 and one-way analysis of variance test were used. We found a high (r=0.88) and significant (p<0.01) correlation between the cement volume and the pull-out strength, which increased by more than 5-fold with a volume of 3 ml. The correlation appeared linear at least up to 4 ml cement volume and failure always occurred at the cement-bone interface. The cement distribution was symmetric and circular around the most proximal hole, with a distance of 14 mm from the tip, and nearly 90% of the cement was found 6 mm distal and cranial to it. The 95% confidence interval for the relative amount of cement was 37%-41% within 2 mm of the most proximal hole. Compared with the control, a cement volume between 2.0 and 3.0 ml increased the pull-out strength significantly and is relevant for clinical purposes, whereas a volume of 0.5 ml did not. A cement volume beyond 3.0 ml should further increase the pull-out strength because the correlation was linear at least up to 4.0 ml, but the possibility of in vivo cement leakage with increasing volume has to be considered. Pressure-controlled cement application might be a tool to avoid this complication. The cement almost completely penetrated the most proximal perforation.

  5. PREFACE: ARENA 2006—Acoustic and Radio EeV Neutrino detection Activities

    NASA Astrophysics Data System (ADS)

    Thompson, Lee

    2007-06-01

    The International Conference on Acoustic and Radio EeV Neutrino Activities, ARENA 2006 was jointly hosted by the Universities of Northumbria and Sheffield at the City of Newcastle Campus of the University of Northumbria in June 2006. ARENA 2006 was the latest in a series of meetings which have addressed, either separately or jointly, the use of radio and acoustic sensors for the detection of highly relativistic particles. Previous successful meetings have taken place in Los Angeles (RADHEP, 2000), Stanford (2003) and DESY Zeuthen (ARENA 2005). A total of 50 scientists from across Europe, the US and Japan attended the conference presenting status reports and results from a number of projects and initiatives spread as far afield as the Sweden and the South Pole. The talks presented at the meeting and the proceedings contained herein represent a `snapshot' of the status of the fields of acoustic and radio detection at the time of the conference. The three day meeting also included two invited talks by Dr Paula Chadwick and Dr Johannes Knapp who gave excellent summaries of the related astroparticle physics fields of high energy gamma ray detection and high energy cosmic ray detection respectively. As well as a full academic agenda there were social events including a Medieval themed conference banquet at Lumley Castle and a civic reception kindly provided by the Lord Mayor of Newcastle and hosted at the Mansion House. Thanks must go to the International Advisory Board members for their input and guidance, the Local Organising Committee for their hard work in bringing everything together and finally the delegates for the stimulating, enthusiastic and enjoyable spirit in which ARENA 2006 took place. Lee Thompson

    International Advisory Board

    G. Anton, ErlangenD. Besson, Kansas
    J. Blümer, KarlsruheA. Capone, Rome
    H. Falcke, BonnP. Gorham, Hawaii
    G. Gratta, StanfordF. Halzen, Madison
    J. Learned, HawaiiR. Nahnhauer, Zeuthen
    A. Rostovtzev, MoscowD. Saltzberg, Los Angeles
    L. Thompson, SheffieldF. Vannucci, Paris

    Local Organizing Committee

    S. Danaher, NorthumbriaC. Rhodes, Imperial College London
    J. Perkin, SheffieldT. Sloan, Lancaster
    L. Thompson, SheffieldD. Waters, University College London

    Participants

    Joseph Allen, Northumbria University, UK Miguel Ardid, Univ. Polit. de Valencia, Spain
    Thomas Asch, IPE, FZKa, Germany Karl-Heinz Becker, BU Wuppertal, Germany
    Dave Besson, U. of Kansas, USA Simon Bevan, University College London, UK
    Manuel Bou Cabo, Politecnic University Valencia, Spain Sebastian Böser, DESY Zeuthen, Germany
    Antonio Capone, University La Sapienza and INFN, Italy Paula Chadwick, University of Durham, UK
    Masami Chiba, Tokyo Metropolitan University, Japan Amy Connolly, UCLA, USA
    Sean Danaher, Northumbria University, UK Giulia De Bonis, Univ. Rome `La Sapienza', Italy
    Freija Descamps, University of Gent, BelgiumKay Graf, University of Erlangen, Germany
    Andreas Haungs, Forschungszentrum Karlsruhe, Germany Kara Hoffman, University of Maryland, USA
    Stephen Hoover, UCLA, USA Tim Huege, Forschungszentrum Karlsruhe, Germany
    Paula Gina Isar, Forschungszentrum Karlsruhe, Germany Timo Karg, BU Wuppertal, Germany
    Johannes Knapp, University of Leeds, UK Robert Lahmann, University of Erlangen, Germany
    Mark Lancaster, University College London, UK Vladimir Lyashuk, ITEP, Russia
    Radovan Milincic, University of Hawaii at Manoa, USA Rolf Nahnhauer, DESY, Zeuthen, Germany
    Christopher Naumann, University of Erlangen, Germany Valentin Niess, CPPM
    Jonathan Perkin, University of Sheffield, UK Steve Ralph, University of Sheffield, UK
    Christopher Rhodes, Imperial College London, UK Carsten Richardt, University of Erlangen, Germany
    Karsten Salomon, University of Erlangen, Germany Olaf Scholten, KVI/University of Groningen, Netherlands
    Terry Sloan, University of Lancaster, UK Pierre Sokolsky, University of Utah, USA
    Lee Thompson, University of Sheffield, UK Omar Veledar, Northumbria University, UK
    David Waters, UCL, USA Dawn Williams, Pennsylvania State University, USA
    Igor Zheleznykh, Institute for Nuclear Research, Russia
    Conference photograph

  6. Comparison of an Oscillometric Method with Cardiac Magnetic Resonance for the Analysis of Aortic Pulse Wave Velocity

    PubMed Central

    Feistritzer, Hans-Josef; Reinstadler, Sebastian J.; Klug, Gert; Kremser, Christian; Seidner, Benjamin; Esterhammer, Regina; Schocke, Michael F.; Franz, Wolfgang-Michael; Metzler, Bernhard

    2015-01-01

    Objectives Pulse wave velocity (PWV) is the proposed gold-standard for the assessment of aortic elastic properties. The aim of this study was to compare aortic PWV determined by a recently developed oscillometric device with cardiac magnetic resonance imaging (CMR). Methods PWV was assessed in 40 volunteers with two different methods. The oscillometric method (PWVOSC) is based on a transfer function from the brachial pressure waves determined by oscillometric blood pressure measurements with a common cuff (Mobil-O-Graph, I.E.M. Stolberg, Germany). CMR was used to determine aortic PWVCMR with the use of the transit time method based on phase-contrast imaging at the level of the ascending and abdominal aorta on a clinical 1.5 Tesla scanner (Siemens, Erlangen, Germany). Results The median age of the study population was 34 years (IQR: 24–55 years, 11 females). A very strong correlation was found between PWVOSC and PWVCMR (r = 0.859, p < 0.001). Mean PWVOSC was 6.7 ± 1.8 m/s and mean PWVCMR was 6.1 ± 1.8 m/s (p < 0.001). Analysis of agreement between the two measurements using Bland-Altman method showed a bias of 0.57 m/s (upper and lower limit of agreement: 2.49 m/s and -1.34 m/s). The corresponding coefficient of variation between both measurements was 15%. Conclusion Aortic pulse wave velocity assessed by transformation of the brachial pressure waveform showed an acceptable agreement with the CMR-derived transit time method. PMID:25612307

  7. Bone condition of the maxillary zygomatic process prior to orthodontic anchorage plate fixation.

    PubMed

    Präger, T M; Brochhagen, H G; Mischkowski, R; Jost-Brinkmann, P G; Müller-Hartwich, R

    2015-01-01

    The clinical success of orthodontic miniplates depends on the stability of the miniscrews used for fixation. For good stability, it is essential that the application site provides enough bone of good quality. This study was performed to analyze the amount of bone available for orthodontic miniplates in the zygomatic process of the maxilla. We examined 51 dental CT scans (Somatom Plus 4; Siemens, Erlangen, Germany) obtained from 51 fully dentate adult patients (mean age 24.0 ± 8.1 years; 27 male and 24 female) prior to third molar surgery. The amount of bone in the zygomatic process region at the level of the first molar root tips and at several other cranial levels as far as 15 mm from the root tips was measured Bone thickness at the root tip level averaged 4.1 ± 1.0 mm; the lowest value measured at this level in any of the patients was 2.7 mm. Bone thickness averaged 8.3 ± 1.0 mm at 15 mm cranial to the root tips; 6.9 mm was the lowest value. The zygomatic process appears to provide sufficient bone to accommodate screws for miniplate fixation. While some patients may possess a borderline amount of bone at more caudal levels, lack of volume is not a problem near the zygomatic bone.

  8. Fas Protects Breast Cancer Stem Cells from Death

    DTIC Science & Technology

    2015-10-01

    proteins. B: All proteins from A that were deregulated at least 1.5 fold in the opposite direction in either analysis. Proteins in red have been...for Clinical Research (IZKF) at the University Hospital of the Friedrich- Alexander-University Erlangen-Nuremberg, in Germany , that I have

  9. Oscillometric analysis compared with cardiac magnetic resonance for the assessment of aortic pulse wave velocity in patients with myocardial infarction.

    PubMed

    Feistritzer, Hans-Josef; Klug, Gert; Reinstadler, Sebastian J; Reindl, Martin; Mayr, Agnes; Schocke, Michael; Metzler, Bernhard

    2016-09-01

    Measurement of aortic pulse wave velocity (PWV) is the gold standard for assessment of aortic stiffness. In patients with ST-segment elevation myocardial infarction (STEMI), high aortic PWV has deleterious effects on the myocardium. In the present study, we compared a novel oscillometric device with cardiac magnetic resonance (CMR) imaging for the assessment of aortic PWV in STEMI patients. We measured aortic PWV in 60 reperfused STEMI patients using two different methods. The oscillometric method (PWVOSC) is based on mathematical transformation of brachial pressure waveforms, oscillometrically determined using a common cuff (Mobil-O-Graph, I.E.M., Stolberg, North Rhine-Westphalia, Germany). Phase-contrast CMR imaging (1.5 T scanner, Siemens, Erlangen, Bavaria, Germany) at the level of the ascending and abdominal aorta was performed to determine CMR-derived pulse wave velocity with the use of the transit time method. The mean age of the study population was 57 ± 11 years; 11 (18%) were women. Median PWVOSC was 7.4 m/s (interquartile range 6.8-8.9 m/s), and median CMR-derived pulse wave velocity was 6.3 m/s (interquartile range 5.7-8.2 m/s) (P < 0.001). A strong correlation was detected between both methods (r = 0.724, P < 0.001). Bland-Altman analysis revealed a bias of 0.62 m/s (upper and lower limit of agreement: 3.84 and -2.61 m/s). The coefficient of variation between both methods was 21%. In reperfused STEMI patients, aortic PWV assessed noninvasively by transformation of brachial pressure waveforms showed an acceptable agreement with the CMR-derived transit time method.

  10. Near East/South Asia Report

    DTIC Science & Technology

    1986-10-27

    MAN), Siemens and Kraftwerk Union (KIW), all of West Germany; South Korea’s Samsung Corporation; Mitsubishi Heavy Industries and Marubeni...Gruppo Industrie Elettro~ meccaniche per Impianti all’Estero (GIE), and Switzerland’s BBC Brown. Boveri & Company, Kraftwerk Union and Siemens, both

  11. [History of the German-Japanese Society of Dermatology].

    PubMed

    Nishioka, Kiyoshi

    2017-03-01

    The relationships between German and Japanese dermatology are traditionally very strong. This fact led Professor Hornstein and Professor Nishiyama to organize joint meetings of dermatologists from both countries. The first meeting of the German-Japanese Society of Dermatology was held in Erlangen, Germany, following the 16th World Congress of Dermatology in 1967. Since then, meetings have been held alternating between Germany and Japan. These meetings were successfully organized by professors from both countries. In this article, I present memorable photos from these joint meetings.

  12. MR-compatible polyetheretherketone-based guide wire assisting MR-guided stenting of iliac and supraaortic arteries in swine: feasibility study.

    PubMed

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz

    2009-01-01

    The purpose of this study was to demonstrate first magnetic resonance (MR)-guided stenting of iliac and supraaortic arteries using a polyetheretherketone-based (PEEK) MR-compatible guide wire. In vitro and animal experiments were performed in a short magnet wide-bore scanner (1.5 Tesla, Espree, Siemens Healthcare, Erlangen, Germany). For all experiments, a 0.035'' MR-compatible guide wire prototoype was used. This wire had a compound core of PEEK with reinforcing fibres, a soft and atraumatic tip and a hydrophilic coating. For its passive visualization, paramagnetic markings were attached. All experiments were performed through a vascular introducer sheath under MR-guidance. In vitro repetitive selective over the wire catheterizations of either the right carotid artery and the left subclavian artery were performed. In vivo, selective catheterization and over-the-wire stenting of the brachiocephalic trunk and the left subclavian artery were performed. The common iliac arteries were catheterized retrogradely (left) and cross-over (right). Angioplasty and stenting were performed over-the-wire. All procedures were successful. Visibility of the PEEK-based guide-wire was rated good in vitro and acceptable in vivo. Guide wire pushability and endovascular device support were good. The PEEK-based MR-compatible guide wire is well visible and usable under MR-guidance. It supports over-the-wire treatment of iliac arteries and supraaortic arteries.

  13. Application of a protocol for magnetic resonance spectroscopy of adrenal glands: an experiment with over 100 cases.

    PubMed

    Melo, Homero José de Farias E; Goldman, Suzan M; Szejnfeld, Jacob; Faria, Juliano F; Huayllas, Martha K P; Andreoni, Cássio; Kater, Cláudio E

    2014-01-01

    To evaluate a protocol for two-dimensional (2D) hydrogen proton (1H) magnetic resonance spectroscopy (MRS) (Siemens Medical Systems; Erlangen, Germany) in the detection of adrenal nodules and differentiation between benign and malignant masses (adenomas, pheochromocytomas, carcinomas and metastases). A total of 118 patients (36 men; 82 women) (mean age: 57.3 ± 13.3 years) presenting with 138 adrenal nodules/masses were prospectively assessed. A multivoxel system was utilized with a 2D point-resolved spectroscopy/chemical shift imaging sequence. The following ratios were calculated: choline (Cho)/creatine (Cr), 4.0-4.3/Cr, lipid (Lip)/Cr, Cho/Lip and lactate (Lac)/Cr. 2D-1H-MRS was successful in 123 (89.13%) lesions. Sensitivity and specificity values observed for the ratios and cutoff points were the following: Cho/Cr ≥ 1.2, 100% sensitivity, 98.2% specificity (differences between adenomas/pheochromocytomas and carcinomas/ metastases); 4.0-4.3 ppm/Cr ≥ 1.5, 92.3% sensitivity, 96.9% specificity (differences between carcinomas/pheochromocytomas and adenomas/metastases); Lac/Cr ≤ -7.449, 90.9% sensitivity and 77.8% specificity (differences between pheochromocytomas and carcinomas/adenomas). Information provided by 2D-1H-MRS were effective and allowed for the differentiation between adrenal masses and nodules in most cases of lesions with > 1.0 cm in diameter.

  14. [The "Erlangen System" of open care: a tribute to Gustav Kolb (1870-1938)].

    PubMed

    Braun, B; Kornhuber, J

    2014-07-01

    This year marks the 80th anniversary of the forced retirement (1st March 1934) of Gustav Kolb (1870 - 1938). He is considered the founder of the "Erlangen System" of open care. The following article pays tribute to Gustav Kolb's "life's work", by delineating the formation, active period and the fall of his "Erlangen system" in its historical context. Relevant archive materials and secondary literature were assessed. Beginning in 1914, Gustav Kolb, as Director of the Mental Asylum in Erlangen (1911 - 1934) introduced the care of the emotionally ill in their own families. In 1930, 4200 of the 770 000 residents in a catchment area covering about 3200 square kilometers were being treated in open care. The "Erlangen system" was the largest organisation of its kind in Germany. Although Gustav Kolb was inspired by eugenic ideas, he opposed the national-socialist health politics. Kolb withdrew professionally in 1933 and died five years later. The situation in the tense area of open care between helping institutions for and controlling bodies over emotionally ill people was relatively balanced in the Weimar Republic. Later, Gustav Kolb's organisational thoroughness, with its creation of a central register of people under open care in the Erlangen system, provided considerable biogenetic information. Tragically, this was abused as an important source in carrying out the national-socialist law for prevention of genetically-impaired offspring (14.7.1933). Several aspects contributed to the misfortune that Kolb's liberal system could be distorted to a recording instrument by the National Socialists. Final Comment: Individual efforts to reestablish open care facilities after 1945 were not implemented. It was not until during the socio-psychiatric movement of the 1960 s that Kolb's concept could achieve a renaissance, although it was unnamed and unrecognised at the time. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Editorial and Forum

    NASA Astrophysics Data System (ADS)

    Caulfield, H. J.

    1981-12-01

    The Kingslake Awards The Rudolf Kingslake Medal and Prize for the most noteworthy original paper to appear in Optical Engineering Volume 19 (1980) has been awarded to G. Ferran° and G. Hausler of the Physikalisches 'Institut of the Universitat Er-langen, Germany, for their paper, "TV Optical Feedback Systems," which appeared in the July/August 1980 issue, pages 442-451.

  16. Manual, semiautomated, and fully automated measurement of the aortic annulus for planning of transcatheter aortic valve replacement (TAVR/TAVI): analysis of interchangeability.

    PubMed

    Lou, Junyang; Obuchowski, Nancy A; Krishnaswamy, Amar; Popovic, Zoran; Flamm, Scott D; Kapadia, Samir R; Svensson, Lars G; Bolen, Michael A; Desai, Milind Y; Halliburton, Sandra S; Tuzcu, E Murat; Schoenhagen, Paul

    2015-01-01

    Preprocedural 3-dimensional CT imaging of the aortic annular plane plays a critical role for transcatheter aortic valve replacement (TAVR) planning; however, manual reconstructions are complex. Automated analysis software may improve reproducibility and agreement between readers but is incompletely validated. In 110 TAVR patients (mean age, 81 years; 37% female) undergoing preprocedural multidetector CT, automated reconstruction of the aortic annular plane and planimetry of the annulus was performed with a prototype of now commercially available software (syngo.CT Cardiac Function-Valve Pilot; Siemens Healthcare, Erlangen, Germany). Fully automated, semiautomated, and manual annulus measurements were compared. Intrareader and inter-reader agreement, intermodality agreement, and interchangeability were analyzed. Finally, the impact of these measurements on recommended valve size was evaluated. Semiautomated analysis required major correction in 5 patients (4.5%). In the remaining 95.5%, only minor correction was performed. Mean manual annulus area was significantly smaller than fully automated results (P < .001 for both readers) but similar to semiautomated measurements (5.0 vs 5.4 vs 4.9 cm(2), respectively). The frequency of concordant recommendations for valve size increased if manual analysis was replaced with the semiautomated method (60% agreement was improved to 82.4%; 95% confidence interval for the difference [69.1%-83.4%]). Semiautomated aortic annulus analysis, with minor correction by the user, provides reliable results in the context of TAVR annulus evaluation. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  17. Differential regional gray matter volumes in patients with on-line game addiction and professional gamers

    PubMed Central

    Han, Doug Hyun; Lyoo, In Kyoon; Renshaw, Perry F.

    2015-01-01

    Patients with on-line game addiction (POGA) and professional video game players play video games for extended periods of time, but experience very different consequences for their on-line game play. Brain regions consisting of anterior cingulate, thalamus and occpito-temporal areas may increase the likelihood of becoming a pro-gamer or POGA. Twenty POGA, seventeen pro-gamers, and eighteen healthy comparison subjects (HC) were recruited. All magnetic resonance imaging (MRI) was performed on a 1.5 Tesla Espree MRI scanner (SIEMENS, Erlangen, Germany). Voxel-wise comparisons of gray matter volume were performed between the groups using the two-sample t-test with statistical parametric mapping (SPM5). Compared to HC, the POGA group showed increased impulsiveness and perseverative errors, and volume in left thalamus gray matter, but decreased gray matter volume in both inferior temporal gyri, right middle occipital gyrus, and left inferior occipital gyrus, compared with HC. Pro-gamers showed increased gray matter volume in left cingulate gyrus, but decreased gray matter volume in left middle occipital gyrus and right inferior temporal gyrus compared with HC. Additionally, the pro-gamer group showed increased gray matter volume in left cingulate gyrus and decreased left thalamus gray matter volume compared with the POGA group. The current study suggests that increased gray matter volumes of the left cingulate gyrus in pro-gamers and of the left thalamus in POGA may contribute to the different clinical characteristics of pro-gamers and POGA. PMID:22277302

  18. Managing Life-Cycle Information of Aircraft Components

    DTIC Science & Technology

    2012-04-01

    Journal of Production Economics , 128(1), 393–403. Ferrer, G., Dew, n., & Apte, U. (2010). When is RFiD right for your Service? International Journal of Production Economics , 124... International Journal of Production Economics , 133(2), 612–621. Hozak, K., & Hill, J. (2010). The material handling trade-off when lot splitting with...pp. 38–56). erlangen, Germany: Publicis Publishing. Ferrer, G. (2010). Open architecture, inventory

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wunderle, K; Wayne State University School of Medicine, Detroit, MI; Godley, A

    Purpose: The purpose of this investigation is to characterize and quantify X-ray beam profiles for fluoroscopic x-ray beam spectra incorporating spectral (copper) filtration. Methods: A PTW (Freiburg, Germany) type 60016 silicon diode detector and PTW MP3 water tank were used to measure X-ray beam profiles for 60, 80, 100 and 120 kVp x-ray beams at five different copper filtration thicknesses ranging from 0–0.9 mm at 22 and 42 cm fields of view and depths of 1, 5, and 10 cm in both the anode-cathode axis (inplane) and cross-plane directions. All measurements were acquired on a Siemens (Erlangen, Germany) Artis ZeeGomore » fluoroscope inverted from the typical orientation providing an x-ray beam originating from above the water surface with the water level set at 60 cm from the focal spot. Results: X-ray beam profiles for beam spectra without copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. Our data collection benefited from the geometric orientation of the fluoroscope, providing a beam perpendicular to the tank water surface, rather than through a thin side wall as did the previously mentioned study. Profiles for beams with copper filtration were obtained which have not been previously investigated and published. Beam profiles in the anode-cathode axis near the surface and at lower x-ray energy exhibited substantial heel effect, which became less pronounced at greater depth. At higher energy with copper filtration in the beam, the dose falloff out-of-field became less pronounced, as would be anticipated given higher scatter photon energy. Conclusion: The x-ray beam profile data for the fluoroscopic x-ray beams incorporating copper filtration are intended for use as reference data for estimating doses to organs or soft tissue, including fetal dose, involving similar beam qualities or for comparison with mathematical models.« less

  20. SU-D-209-02: Percent Depth Dose Curves for Fluoroscopic X-Ray Beam Qualities Incorporating Copper Filtration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wunderle, K; Wayne State University School of Medicine, Detroit, MI; Godley, A

    Purpose: The purpose of this investigation was to quantify percent depth dose (PDD) curves for fluoroscopic x-ray beam qualities incorporating added copper filtration. Methods: A PTW (Freiburg, Germany) MP3 water tank was used with a Standard Imaging (Middleton, WI) Exradin Model 11 Spokas Chamber to measure PDD curves for 60, 80, 100 and 120 kVp x-ray beams with copper filtration ranging from 0.0–0.9 mm at 22cm and 42cm fields of view from 0 to 150 mm of water. A free-in-air monitor chamber was used to normalize the water tank data to fluctuations in output from the fluoroscope. The measurements weremore » acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope. The fluoroscope was inverted from the typical orientation providing an x-ray beam originating from above the water tank. The water tank was positioned so that the water level was located at 60cm from the focal spot; which also represents the focal spot to interventional reference plane distance for that fluoroscope. Results: PDDs for 60, 80, 100, and 120 kVp with 0 mm of copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)] for those beam qualities given differences in fluoroscopes, geometric orientation, type of ionization chamber, and the water tank used for data collection. PDDs for 60, 80, 100, and 120 kVp with copper filtration were obtained and are presented, which have not been previously investigated and published. Conclusion: The equipment and processes used to acquire the reported data were sound and compared well with previously published data for PDDs without copper filtration. PDD data for the fluoroscopic x-ray beams incorporating copper filtration can be used as reference data for estimating organ or soft tissue dose at depth involving similar beam qualities or for comparison with mathematical models.« less

  1. Increased extracellular volume and altered mechanics are associated with LVH in hypertensive heart disease, not hypertension alone.

    PubMed

    Kuruvilla, Sujith; Janardhanan, Rajesh; Antkowiak, Patrick; Keeley, Ellen C; Adenaw, Nebiyu; Brooks, Jeremy; Epstein, Frederick H; Kramer, Christopher M; Salerno, Michael

    2015-02-01

    The goal of this study was to assess the relationship among extracellular volume (ECV), native T1, and systolic strain in hypertensive patients with left ventricular hypertrophy (HTN LVH), hypertensive patients without LVH (HTN non-LVH), and normotensive controls. Diffuse myocardial fibrosis in HTN LVH patients, as reflected by increased ECV and native T1, may be an underlying mechanism contributing to increased cardiovascular risk compared with HTN non-LVH subjects and controls. Furthermore, increased diffuse fibrosis in HTN LVH subjects may be associated with reduced peak systolic and early diastolic strain rate compared with the other 2 groups. T1 mapping was performed in 20 HTN LVH (mean age, 55 ± 11 years), 23 HTN non-LVH (mean age, 61 ± 12 years), and 22 control subjects (mean age, 54 ± 7 years) on a Siemens 1.5-T Avanto (Siemens Healthcare, Erlangen, Germany) using a previously validated modified look-locker inversion-recovery pulse sequence. T1 was measured pre-contrast and 10, 15, and 20 min after injection of 0.15 mmol/kg gadopentetate dimeglumine, and the mean ECV and native T1 were determined for each subject. Measurement of circumferential strain parameters were performed using cine displacement encoding with stimulated echoes. HTN LVH subjects had higher native T1 compared with controls (p < 0.05). HTN LVH subjects had higher ECV compared with HTN non-LVH subjects and controls (p < 0.05). Peak systolic circumferential strain and early diastolic strain rates were reduced in HTN LVH subjects compared with HTN non-LVH subjects and controls (p < 0.05). Increased levels of ECV and native T1 were associated with reduced peak systolic and early diastolic circumferential strain rate across all subjects. HTN LVH patients had higher ECV, longer native T1 and associated reduction in peak systolic circumferential strain, and early diastolic strain rate compared with HTN non-LVH and control subjects. Measurement of ECV and native T1 provide a noninvasive assessment of diffuse fibrosis in hypertensive heart disease. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Good, but Not Perfect: Parental Knowledge About Risk Factors for Skin Cancer and the Necessity of Sun Protection in Southern Germany.

    PubMed

    Gefeller, Olaf; Uter, Wolfgang; Pfahlberg, Annette B

    2015-01-01

    The level of knowledge and awareness of skin cancer risks in parents of young children is largely unknown. The Erlangen Kindergarten study, which enrolled 3,129 parents of 3- to 6-year-old children in southern Germany, addressed this. The population-based survey found an overall high level of knowledge about skin cancer risks and strong support for the necessity of sun protection but identified two areas (role of intermittent sun exposure, sun protection on cloudy summer days) offering a target for improvement in future public health campaigns. © 2015 Wiley Periodicals, Inc.

  3. Electronic Materials and Applications 2014 (Abstracts)

    DTIC Science & Technology

    2015-04-02

    the thermal image using IR camera and surface tempera- ture using thermo couple. Lastly, we conducted a surface coating to change the surface...progress in the superconducting films and coated conductors of iron chalcogenides. With a CeO2 buffer , critical current densities (Jc) over 7 MA/cm2...Roosen, University of Erlangen-Nuremberg, Germany Kato, N. 23-Jan 11:15AM Pacific 11:30 AM (EMA-S1-021-2014) Glass-like Thermal Conductivity of (010

  4. Wavelet Entropy and Directed Acyclic Graph Support Vector Machine for Detection of Patients with Unilateral Hearing Loss in MRI Scanning

    PubMed Central

    Wang, Shuihua; Yang, Ming; Du, Sidan; Yang, Jiquan; Liu, Bin; Gorriz, Juan M.; Ramírez, Javier; Yuan, Ti-Fei; Zhang, Yudong

    2016-01-01

    Highlights We develop computer-aided diagnosis system for unilateral hearing loss detection in structural magnetic resonance imaging.Wavelet entropy is introduced to extract image global features from brain images. Directed acyclic graph is employed to endow support vector machine an ability to handle multi-class problems.The developed computer-aided diagnosis system achieves an overall accuracy of 95.1% for this three-class problem of differentiating left-sided and right-sided hearing loss from healthy controls. Aim: Sensorineural hearing loss (SNHL) is correlated to many neurodegenerative disease. Now more and more computer vision based methods are using to detect it in an automatic way. Materials: We have in total 49 subjects, scanned by 3.0T MRI (Siemens Medical Solutions, Erlangen, Germany). The subjects contain 14 patients with right-sided hearing loss (RHL), 15 patients with left-sided hearing loss (LHL), and 20 healthy controls (HC). Method: We treat this as a three-class classification problem: RHL, LHL, and HC. Wavelet entropy (WE) was selected from the magnetic resonance images of each subjects, and then submitted to a directed acyclic graph support vector machine (DAG-SVM). Results: The 10 repetition results of 10-fold cross validation shows 3-level decomposition will yield an overall accuracy of 95.10% for this three-class classification problem, higher than feedforward neural network, decision tree, and naive Bayesian classifier. Conclusions: This computer-aided diagnosis system is promising. We hope this study can attract more computer vision method for detecting hearing loss. PMID:27807415

  5. Wavelet Entropy and Directed Acyclic Graph Support Vector Machine for Detection of Patients with Unilateral Hearing Loss in MRI Scanning.

    PubMed

    Wang, Shuihua; Yang, Ming; Du, Sidan; Yang, Jiquan; Liu, Bin; Gorriz, Juan M; Ramírez, Javier; Yuan, Ti-Fei; Zhang, Yudong

    2016-01-01

    Highlights We develop computer-aided diagnosis system for unilateral hearing loss detection in structural magnetic resonance imaging.Wavelet entropy is introduced to extract image global features from brain images. Directed acyclic graph is employed to endow support vector machine an ability to handle multi-class problems.The developed computer-aided diagnosis system achieves an overall accuracy of 95.1% for this three-class problem of differentiating left-sided and right-sided hearing loss from healthy controls. Aim: Sensorineural hearing loss (SNHL) is correlated to many neurodegenerative disease. Now more and more computer vision based methods are using to detect it in an automatic way. Materials: We have in total 49 subjects, scanned by 3.0T MRI (Siemens Medical Solutions, Erlangen, Germany). The subjects contain 14 patients with right-sided hearing loss (RHL), 15 patients with left-sided hearing loss (LHL), and 20 healthy controls (HC). Method: We treat this as a three-class classification problem: RHL, LHL, and HC. Wavelet entropy (WE) was selected from the magnetic resonance images of each subjects, and then submitted to a directed acyclic graph support vector machine (DAG-SVM). Results: The 10 repetition results of 10-fold cross validation shows 3-level decomposition will yield an overall accuracy of 95.10% for this three-class classification problem, higher than feedforward neural network, decision tree, and naive Bayesian classifier. Conclusions: This computer-aided diagnosis system is promising. We hope this study can attract more computer vision method for detecting hearing loss.

  6. Rotational Angiography Based Three-Dimensional Left Atrial Reconstruction: A New Approach for Transseptal Puncture.

    PubMed

    Koektuerk, Buelent; Yorgun, Hikmet; Koektuerk, Oezlem; Turan, Cem H; Gorr, Eduard; Horlitz, Marc; Turan, Ramazan G

    2016-02-01

    Rotational angiography is a well-known method for the three-dimensional (3-D) reconstruction of left atrium and pulmonary veins during left-sided atrial arrhythmia ablation procedures. In our study, we aimed to review our experience in transseptal puncture (TSP) using 3-D rotational angiography. We included a total of 271 patients who underwent atrial fibrillation ablation using cryoballoon. Rotational angiography was performed to get the three-dimensional left atrial and pulmonary vein reconstructions using cardiac C-arm computed tomography. The image reconstruction was made using the DynaCT Cardiac software (Siemens, Erlangen, Germany). The mean age of the study population was 61 ± 10 years. The indications for left atrial arrhythmia ablation were paroxysmal AF in 140 patients (52%) and persistent AF patients in 131 (48%) patients. The success rate of TSP using only rotational guidance was (264/271 patients, 97.4%). In the remaining seven patients, transesophageal guidance was used after the initial attempt due to thick interatrial septum in five patients and difficult TSP due to abnormal anatomy and mild pericardial effusion in the remaining two patients. Mean fluoroscopy dosage of the rotational angiography was 4896.4 ± 825.3 μGym(2). The mean time beginning from femoral vein puncture to TSP was 12.3 ± 5.5 min. TSP guided by rotational angiography is a safe and effective method. Our results indicate that integration of rotational angiographic images into the real-time fluoroscopy can guide the TSP during the procedure. © 2015 John Wiley & Sons Ltd.

  7. Differential regional gray matter volumes in patients with on-line game addiction and professional gamers.

    PubMed

    Han, Doug Hyun; Lyoo, In Kyoon; Renshaw, Perry F

    2012-04-01

    Patients with on-line game addiction (POGA) and professional video game players play video games for extended periods of time, but experience very different consequences for their on-line game play. Brain regions consisting of anterior cingulate, thalamus and occpito-temporal areas may increase the likelihood of becoming a pro-gamer or POGA. Twenty POGA, seventeen pro-gamers, and eighteen healthy comparison subjects (HC) were recruited. All magnetic resonance imaging (MRI) was performed on a 1.5 Tesla Espree MRI scanner (SIEMENS, Erlangen, Germany). Voxel-wise comparisons of gray matter volume were performed between the groups using the two-sample t-test with statistical parametric mapping (SPM5). Compared to HC, the POGA group showed increased impulsiveness and perseverative errors, and volume in left thalamus gray matter, but decreased gray matter volume in both inferior temporal gyri, right middle occipital gyrus, and left inferior occipital gyrus, compared with HC. Pro-gamers showed increased gray matter volume in left cingulate gyrus, but decreased gray matter volume in left middle occipital gyrus and right inferior temporal gyrus compared with HC. Additionally, the pro-gamer group showed increased gray matter volume in left cingulate gyrus and decreased left thalamus gray matter volume compared with the POGA group. The current study suggests that increased gray matter volumes of the left cingulate gyrus in pro-gamers and of the left thalamus in POGA may contribute to the different clinical characteristics of pro-gamers and POGA. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Very low-dose (0.15 mGy) chest CT protocols using the COPDGene 2 test object and a third-generation dual-source CT scanner with corresponding third-generation iterative reconstruction software.

    PubMed

    Newell, John D; Fuld, Matthew K; Allmendinger, Thomas; Sieren, Jered P; Chan, Kung-Sik; Guo, Junfeng; Hoffman, Eric A

    2015-01-01

    The purpose of this study was to evaluate the impact of ultralow radiation dose single-energy computed tomographic (CT) acquisitions with Sn prefiltration and third-generation iterative reconstruction on density-based quantitative measures of growing interest in phenotyping pulmonary disease. The effects of both decreasing dose and different body habitus on the accuracy of the mean CT attenuation measurements and the level of image noise (SD) were evaluated using the COPDGene 2 test object, containing 8 different materials of interest ranging from air to acrylic and including various density foams. A third-generation dual-source multidetector CT scanner (Siemens SOMATOM FORCE; Siemens Healthcare AG, Erlangen, Germany) running advanced modeled iterative reconstruction (ADMIRE) software (Siemens Healthcare AG) was used.We used normal and very large body habitus rings at dose levels varying from 1.5 to 0.15 mGy using a spectral-shaped (0.6-mm Sn) tube output of 100 kV(p). Three CT scans were obtained at each dose level using both rings. Regions of interest for each material in the test object scans were automatically extracted. The Hounsfield unit values of each material using weighted filtered back projection (WFBP) at 1.5 mGy was used as the reference value to evaluate shifts in CT attenuation at lower dose levels using either WFBP or ADMIRE. Statistical analysis included basic statistics, Welch t tests, multivariable covariant model using the F test to assess the significance of the explanatory (independent) variables on the response (dependent) variable, and CT mean attenuation, in the multivariable covariant model including reconstruction method. Multivariable regression analysis of the mean CT attenuation values showed a significant difference with decreasing dose between ADMIRE and WFBP. The ADMIRE has reduced noise and more stable CT attenuation compared with WFBP. There was a strong effect on the mean CT attenuation values of the scanned materials for ring size (P < 0.0001) and dose level (P < 0.0001). The number of voxels in the region of interest for the particular material studied did not demonstrate a significant effect (P > 0.05). The SD was lower with ADMIRE compared with WFBP at all dose levels and ring sizes (P < 0.05). The third-generation dual-source CT scanners using third-generation iterative reconstruction methods can acquire accurate quantitative CT images with acceptable image noise at very low-dose levels (0.15 mGy). This opens up new diagnostic and research opportunities in CT phenotyping of the lung for developing new treatments and increased understanding of pulmonary disease.

  9. [Structural Change, Contextuality, and Transfer in Health Promotion--Sustainable Implementation of the BIG Project].

    PubMed

    Rütten, A; Frahsa, A; Rosenhäger, N; Wolff, A

    2015-09-01

    The BIG approach aims at promoting physical activity and health among socially disadvantaged women. BIG has been developed and sustainably implemented in Erlangen/Bavaria. Subsequently, it has been transferred to other communities and states in Germany. Crucial factors for sustainability and transfer in BIG are (1) lifestyle and policy analysis, (2) assets approach, (3) empowerment of target group, (4) enabling of policy-makers and professionals. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Integrated Assessment of Left Ventricular Electrical Activation and Myocardial Strain Mapping in Heart Failure Patients: A Holistic Diagnostic Approach for Endocardial Cardiac Resynchronization Therapy, Ablation of Ventricular Tachycardia, and Biological Therapy.

    PubMed

    Maffessanti, Francesco; Prinzen, Frits W; Conte, Giulio; Regoli, François; Caputo, Maria Luce; Suerder, Daniel; Moccetti, Tiziano; Faletra, Francesco; Krause, Rolf; Auricchio, Angelo

    2018-01-01

    This study sought to test the accuracy of strain measurements based on anatomo-electromechanical mapping (AEMM) measurements compared with magnetic resonance imaging (MRI) tagging, to evaluate the diagnostic value of AEMM-based strain measurements in the assessment of myocardial viability, and the additional value of AEMM over peak-to-peak local voltages. The in vivo identification of viable tissue, evaluation of mechanical contraction, and simultaneous left ventricular activation is currently achieved using multiple complementary techniques. In 33 patients, AEMM maps (NOGA XP, Biologic Delivery Systems, Division of Biosense Webster, a Johnson & Johnson Company, Irwindale, California) and MRI images (Siemens 3T, Siemens Healthcare, Erlangen, Germany) were obtained within 1 month. MRI tagging was used to determine circumferential strain (E cc ) and delayed enhancement to obtain local scar extent (%). Custom software was used to measure E cc and local area strain (LAS) from the motion field of the AEMM catheter tip. Intertechnique agreement for E cc was good (R 2  = 0.80), with nonsignificant bias (0.01 strain units) and narrow limits of agreement (-0.03 to 0.06). Scar segments showed lower absolute strain amplitudes compared with nonscar segments: E cc (median [first to third quartile]: nonscar -0.10 [-0.15 to -0.06] vs. scar -0.04 [-0.06 to -0.02]) and LAS (-0.20 [-0.27 to -0.14] vs. -0.09 [-0.14 to -0.06]). AEMM strains accurately discriminated between scar and nonscar segments, in particular LAS (area under the curve: 0.84, accuracy = 0.76), which was superior to peak-to-peak voltages (nonscar 9.5 [6.5 to 13.3] mV vs. scar 5.6 [3.4 to 8.3] mV; area under the curve: 0.75). Combination of LAS and peak-to-peak voltages resulted in 86% accuracy. An integrated AEMM approach can accurately determine local deformation and correlates with the scar extent. This approach has potential immediate application in the diagnosis, delivery of intracardiac therapies, and their intraprocedural evaluation. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  11. Comparison of three optical tracking systems in a complex navigation scenario.

    PubMed

    Rudolph, Tobias; Ebert, Lars; Kowal, Jens

    2010-01-01

    Three-dimensional rotational X-ray imaging with the SIREMOBIL Iso-C3D (Siemens AG, Medical Solutions, Erlangen, Germany) has become a well-established intra-operative imaging modality. In combination with a tracking system, the Iso-C3D provides inherently registered image volumes ready for direct navigation. This is achieved by means of a pre-calibration procedure. The aim of this study was to investigate the influence of the tracking system used on the overall navigation accuracy of direct Iso-C3D navigation. Three models of tracking system were used in the study: Two Optotrak 3020s, a Polaris P4 and a Polaris Spectra system, with both Polaris systems being in the passive operation mode. The evaluation was carried out at two different sites using two Iso-C3D devices. To measure the navigation accuracy, a number of phantom experiments were conducted using an acrylic phantom equipped with titanium spheres. After scanning, a special pointer was used to pinpoint these markers. The difference between the digitized and navigated positions served as the accuracy measure. Up to 20 phantom scans were performed for each tracking system. The average accuracy measured was 0.86 mm and 0.96 mm for the two Optotrak 3020 systems, 1.15 mm for the Polaris P4, and 1.04 mm for the Polaris Spectra system. For the Polaris systems a higher maximal error was found, but all three systems yielded similar minimal errors. On average, all tracking systems used in this study could deliver similar navigation accuracy. The passive Polaris system showed – as expected – higher maximal errors; however, depending on the application constraints, this might be negligible.

  12. Novel Software-Assisted Hemodynamic Evaluation of Pelvic Flow During Chemoperfusion of Pelvic Arteries for Bladder Cancer: Double- Versus Single-Balloon Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Kiyohito, E-mail: rad105@poh.osaka-med.ac.jp; Yamamoto, Kazuhiro, E-mail: rad043@poh.osaka-med.ac.jp; Nakai, Go, E-mail: rad091@poh.osaka-med.ac.jp

    2016-06-15

    PurposeApproximately 83 % of patients with bladder cancer have achieved a complete response after undergoing a novel bladder preservation therapy involving balloon-occluded intra-arterial infusion chemotherapy (BOAI) using a four-lumen double-balloon catheter, known as the Osaka Medical College regimen. This study aimed to show the quantitative difference in hemodynamics of the bladder arteries using syngo iFlow (Siemens Healthcare, Erlangen, Germany), which provides an automatic tool for quantitative blood flow analysis between double BOAI (D-BOAI) and conventional single BOAI (S-BOAI).Materials and MethodsFifty patients were included. The catheters were introduced into both posterior trunks of the internal iliac arteries via contralateral femoral artery access.more » A side hole between the distal and proximal balloons was placed at the origin of each bladder artery to allow clear visualization of angiographic flow of the injected agent into the urinary bladder. Digital subtraction angiography was used during analysis with the syngo iFlow to evaluate the hemodynamics of the contrast medium in the pelvic arteries during BOAI. The comparative change in the amount of contrast medium in the bladder arteries between D-BOAI and S-BOAI was assessed using syngo iFlow.ResultsOne-hundred pelvic sides were analyzed. The amount of contrast medium in the bladder arteries using D-BOAI was more than twice that using S-BOAI (right, 3.03-fold; left, 2.81-fold).ConclusionThe amount of contrast medium in the bladder arteries using D-BOAI was higher than that using conventional S-BOAI. This may increase the anticancer drug concentration in the affected bladder, leading to a good clinical response.« less

  13. In vivo 1D and 2D correlation MR spectroscopy of the soleus muscle at 7T

    PubMed Central

    Ramadan, Saadallah; Ratai, Eva-Maria; Wald, Lawrence L.; Mountford, Carolyn E.

    2013-01-01

    Aim This study aims to (1) undertake and analyse 1D and 2D MR correlation spectroscopy from human soleus muscle in vivo at 7T, and (2) determine T1 and T2 relaxation time constants at 7T field strength due to their importance in sequence design and spectral quantitation. Method Six healthy, male volunteers were consented and scanned on a 7T whole-body scanner (Siemens AG, Erlangen, Germany). Experiments were undertaken using a 28 cm diameter detunable birdcage coil for signal excitation and an 8.5 cm diameter surface coil for signal reception. The relaxation time constants, T1 and T2 were recorded using a STEAM sequence, using the ‘progressive saturation’ method for the T1 and multiple echo times for T2. The 2D L-Correlated SpectroscopY (L-COSY) method was employed with 64 increments (0.4 ms increment size) and eight averages per scan, with a total time of 17 min. Results T1 and T2 values for the metabolites of interest were determined. The L-COSY spectra obtained from the soleus muscle provided information on lipid content and chemical structure not available, in vivo, at lower field strengths. All molecular fragments within multiple lipid compartments were chemically shifted by 0.20–0.26 ppm at this field strength. 1D and 2D L-COSY spectra were assigned and proton connectivities were confirmed with the 2D method. Conclusion In vivo 1D and 2D spectroscopic examination of muscle can be successfully recorded at 7T and is now available to assess lipid alterations as well as other metabolites present with disease. T1 and T2 values were also determined in soleus muscle of male healthy volunteers. PMID:20206561

  14. Operator induced variability in left ventricular measurements with cardiovascular magnetic resonance is improved after training.

    PubMed

    Karamitsos, Theodoros D; Hudsmith, Lucy E; Selvanayagam, Joseph B; Neubauer, Stefan; Francis, Jane M

    2007-01-01

    Accurate and reproducible measurement of left ventricular (LV) mass and function is a significant strength of Cardiovascular Magnetic Resonance (CMR). Reproducibility and accuracy of these measurements is usually reported between experienced operators. However, an increasing number of inexperienced operators are now training in CMR and are involved in post-processing analysis. The aim of the study was to assess the interobserver variability of the manual planimetry of LV contours amongst two experienced and six inexperienced operators before and after a two months training period. Ten healthy normal volunteers (5 men, mean age 34+/-14 years) comprised the study population. LV volumes, mass, and ejection fraction were manually evaluated using Argus software (Siemens Medical Solutions, Erlangen, Germany) for each subject, once by the two experienced and twice by the six inexperienced operators. The mean values of experienced operators were considered the reference values. The agreement between operators was evaluated by means of Bland-Altman analysis. Training involved standardized data acquisition, simulated off-line analysis and mentoring. The trainee operators demonstrated improvement in the measurement of all the parameters compared to the experienced operators. The mean ejection fraction variability improved from 7.2% before training to 3.7% after training (p=0.03). The parameter in which the trainees showed the least improvement was LV mass (from 7.7% to 6.7% after training). The basal slice selection and contour definition were the main sources of errors. An intensive two month training period significantly improved the accuracy of LV functional measurements. Adequate training of new CMR operators is of paramount importance in our aim to maintain the accuracy and high reproducibility of CMR in LV function analysis.

  15. CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schaefer, Philipp J., E-mail: jp.schaefer@rad.uni-kiel.de; Fabel, Michael; Bolte, Hendrik

    2010-08-15

    The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helicallymore » bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 {+-} 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 {+-} 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 {+-} 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 {+-} 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 {+-} 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.« less

  16. Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography.

    PubMed

    Dietrich, Tobias J; Pfirrmann, Christian W A; Schwab, Alexander; Pankalla, Katja; Buck, Florian M

    2013-07-01

    To compare the radiation dose, workflow, patient comfort, and financial break-even of a standard digital radiography and a biplanar low-dose X-ray system. A standard digital radiography system (Ysio, Siemens Healthcare, Erlangen, Germany) was compared with a biplanar X-ray unit (EOS, EOS imaging, Paris, France) consisting of two X-ray tubes and slot-scanning detectors, arranged at an angle of 90° allowing simultaneous vertical biplanar linear scanning in the upright patient position. We compared data of standing full-length lower limb radiographs and whole spine radiographs of both X-ray systems. Dose-area product was significantly lower for radiographs of the biplanar X-ray system than for the standard digital radiography system (e.g. whole spine radiographs; standard digital radiography system: 392.2 ± 231.7 cGy*cm(2) versus biplanar X-ray system: 158.4 ± 103.8 cGy*cm(2)). The mean examination time was significantly shorter for biplanar radiographs compared with standard digital radiographs (e.g. whole spine radiographs: 449 s vs 248 s). Patients' comfort regarding noise was significantly higher for the standard digital radiography system. The financial break-even point was 2,602 radiographs/year for the standard digital radiography system compared with 4,077 radiographs/year for the biplanar X-ray unit. The biplanar X-ray unit reduces radiation exposure and increases subjective noise exposure to patients. The biplanar X-ray unit demands a higher number of examinations per year for the financial break-even point, despite the lower labour cost per examination due to the shorter examination time.

  17. Evaluating the effect of increased pitch, iterative reconstruction and dual source CT on dose reduction and image quality.

    PubMed

    Gariani, Joanna; Martin, Steve P; Botsikas, Diomidis; Becker, Christoph D; Montet, Xavier

    2018-06-14

    To compare radiation dose and image quality of thoracoabdominal scans obtained with a high-pitch protocol (pitch 3.2) and iterative reconstruction (Sinogram Affirmed Iterative Reconstruction) in comparison to standard pitch reconstructed with filtered back projection (FBP) using dual source CT. 114 CT scans (Somatom Definition Flash, Siemens Healthineers, Erlangen, Germany), 39 thoracic scans, 54 thoracoabdominal scans and 21 abdominal scans were performed. Analysis of three protocols was undertaken; pitch of 1 reconstructed with FBP, pitch of 3.2 reconstructed with SAFIRE, pitch of 3.2 with stellar detectors reconstructed with SAFIRE. Objective and subjective image analysis were performed. Dose differences of the protocols used were compared. Dose was reduced when comparing scans with a pitch of 1 reconstructed with FBP to high-pitch scans with a pitch of 3.2 reconstructed with SAFIRE with a reduction of volume CT dose index of 75% for thoracic scans, 64% for thoracoabdominal scans and 67% for abdominal scans. There was a further reduction after the implementation of stellar detectors reflected in a reduction of 36% of the dose-length product for thoracic scans. This was not at the detriment of image quality, contrast-to-noise ratio, signal-to-noise ratio and the qualitative image analysis revealed a superior image quality in the high-pitch protocols. The combination of a high pitch protocol with iterative reconstruction allows significant dose reduction in routine chest and abdominal scans whilst maintaining or improving diagnostic image quality, with a further reduction in thoracic scans with stellar detectors. Advances in knowledge: High pitch imaging with iterative reconstruction is a tool that can be used to reduce dose without sacrificing image quality.

  18. Elasticity standard values of the Achilles tendon assessed with acoustic radiation force impulse elastography on healthy volunteers: a cross section study.

    PubMed

    Wakker, Jonas; Kratzer, Wolfgang; Graeter, Tilmann; Schmidberger, Julian

    2018-05-09

    To determine normal values for acoustic radiation force impulse (ARFI) shear wave elastography of the Achilles tendon. Using the VTIQ mode with the Acuson S3000™ (Siemens Healthcare, Erlangen, Germany), we measured the shear wave velocity (SWV) in m/s and the diameter in mm of both Achilles tendons in 182 healthy volunteers. The tendon was displayed in a sagittal view with a relaxed tendon. The parameters were tested for correlations with the anthropometric data of the subjects, between the genders and different age groups, as well as information obtained from the history, such as smoking and sporting activities. Using a sagittal acoustic window, we determined a mean SWV of 9.09 ± 0.71 m/s for the left Achilles tendon and 9.17 ± 0.61 m/s for the right. There was a significant difference between the results for the right and left side (p < 0.05). The diameter on the left was 4.7 ± 0.9 mm. On the right, it was 4.8 ± 0.9 mm. Likewise there was a significant difference between the results for the diameter of the left and right side (p < 0.05). Neither gender, body mass index (BMI) nor age had a significant effect on either of the measured parameters (p > 0.05). The same goes for the consumption of tobacco and alcohol (p > 0.05). Age, gender, BMI, smoking or the consumption of alcohol did not affect either the elasticity or the diameter of the Achilles tendon.

  19. Radiofrequency heating of metallic dental devices during 3.0 T MRI

    PubMed Central

    Hasegawa, M; Miyata, K; Abe, Y; Ishigami, T

    2013-01-01

    Objectives: To estimate the risk of injury from radiofrequency (RF) heating of metallic dental devices in use during 3.0 T MRI. Methods: The whole-body specific absorption rate (WB-SAR) was calculated on the basis of saline temperature elevation under the maximum RF irradiation for 15 min to determine the operation parameters for the heating test. The temperature changes of three types of three-unit bridges, a full-arch fixed dental prosthesis and an orthodontic appliance in use during MRI with a 3.0 T MR system (Magnetom® Verio; Siemens AG, Erlangen, Germany) were then tested in accordance with the American Society for Testing and Materials F2182-09 standardized procedure under the maximum RF heating during 15 min RF irradiation. Results: The system console-predicted WB-SAR was approximately 1.4 W kg−1 and that measured with a saline phantom was 2.1 W kg−1. In the assessment of RF heating, the highest temperature increase was +1.80 °C in the bridges, +1.59 °C in the full-arch fixed dental prosthesis and +2.61 °C in the orthodontic appliance. Conclusions: The relatively minor RF heating of dental casting material-based prostheses in Magnetom Verio systems in the normal operating mode should not pose a risk to patients. However, orthodontic appliances may exhibit RF heating above the industrial standard (CENELEC standard prEN45502-2-3); therefore, the wire should be removed from the bracket or a spacer should be used between the appliance and the oral mucosa during MRI. PMID:23520391

  20. Liver Stiffness Measurements Using Acoustic Radiation Force Impulse in Recipients of Living-Donor and Deceased-Donor Orthotopic Liver Transplant.

    PubMed

    Haberal, Kemal Murat; Turnaoğlu, Hale; Özdemir, Adnan; Uslu, Nihal; Haberal Reyhan, Asuman Nihan; Moray, Gökhan; Haberal, Mehmet

    2017-08-24

    The aim of this study was to evaluate the diagnostic efficiency of the acoustic radiation force impulse (Siemens Medical Solutions, Erlangen, Germany) elastography in assessment of fibrosis in orthotopic liver transplant patients. We enrolled 28 orthotopic liver transplant patients (deceased and living donors), whose biopsy decision had been prospectively given clinically. Ten acoustic radiation force impulse elastographic measurements were applied before the biopsy or within 3 days after the biopsy by 2 radiologists. After the core tissue needle biopsy, specimens of all patients were analyzed according to the modified Ishak scoring system. Measurements of acoustic radiation force impulse elastography and pathology specimen results were compared. From 28 biopsies, fibrosis scores of 4 biopsies were evaluated as F0 (14.3%), 16 as F1 (57.1%), 4 as F2 (14.3%), and 4 as F3 (14.3%). Mean results of acoustic radiation force impulse measurements were calculated as 1.4 ± 0.07 in F0, 1.74 ± 0.57 in F1, 2.19 ± 0.7 in F2, and 2.18 ± 0.35 in F3. There were no significant correlations of mean acoustic radiation force impulse values between the F0 versus F1 (P = .956) and F0 versus F2 stages (P = .234). A statistically significant correlation of mean acoustic radiation force impulse values was found between the F0 and F3 fibrosis stages (P = .046). Acoustic radiation force impulse imaging is a promising screening test for detecting significant liver fibrosis (≥ F3 in modified Ishak) in living-donor or deceased-donor orthotopic liver transplant recipients.

  1. Robotically assisted MRgFUS system

    NASA Astrophysics Data System (ADS)

    Jenne, Jürgen W.; Krafft, Axel J.; Maier, Florian; Rauschenberg, Jaane; Semmler, Wolfhard; Huber, Peter E.; Bock, Michael

    2010-03-01

    Magnetic resonance imaging guided focus ultrasound surgery (MRgFUS) is a highly precise method to ablate tissue non-invasively. The objective of this ongoing work is to establish an MRgFUS therapy unit consisting of a specially designed FUS applicator as an add-on to a commercial robotic assistance system originally designed for percutaneous needle interventions in whole-body MRI systems. The fully MR compatible robotic assistance system InnoMotion™ (Synthes Inc., West Chester, USA; formerly InnoMedic GmbH, Herxheim, Germany) offers six degrees of freedom. The developed add-on FUS treatment applicator features a fixed focus ultrasound transducer (f = 1.7 MHz; f' = 68 mm, NA = 0.44, elliptical shaped -6-dB-focus: 8.1 mm length; O/ = 1.1 mm) embedded in a water-filled flexible bellow. A Mylar® foil is used as acoustic window encompassed by a dedicated MRI loop coil. For FUS application, the therapy unit is directly connected to the head of the robotic system, and the treatment region is targeted from above. A newly in-house developed software tool allowed for complete remote control of the MRgFUS-robot system and online analysis of MRI thermometry data. The system's ability for therapeutic relevant focal spot scanning was tested in a closed-bore clinical 1.5 T MR scanner (Magnetom Symphony, Siemens AG, Erlangen, Germany) in animal experiments with pigs. The FUS therapy procedure was performed entirely under MRI guidance including initial therapy planning, online MR-thermometry, and final contrast enhanced imaging for lesion detection. In vivo trials proved the MRgFUS-robot system as highly MR compatible. MR-guided focal spot scanning experiments were performed and a well-defined pattern of thermal tissue lesions was created. A total in vivo positioning accuracy of the US focus better than 2 mm was estimated which is comparable to existing MRgFUS systems. The newly developed FUS-robotic system offers an accurate, highly flexible focus positioning. With its access to the patient from above, it provides a wide range of flexibility for acoustic target access. In the next step, motion correction unit should be integrated.

  2. SU-F-I-72: Evaluation of the Ancillary Lead Shielding for Optimizing Radiation Protection in the Interventional Radiology Department

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tonkopi, E; Lightfoot, C; LeBlanc, E

    Purpose: The rising complexity of interventional fluoroscopic procedures has resulted in an increase of occupational radiation exposures in the interventional radiology (IR) department. This study assessed the impact of ancillary shielding on optimizing radiation protection for the IR staff. Methods: Scattered radiation measurements were performed in two IR suites equipped with Axiom Artis systems (Siemens Healthcare, Erlangen, Germany) installed in 2006 and 2010. Both rooms had suspended ceiling-mounted lead-acrylic shields of 75×60 cm (Mavig, Munich, Germany) with lead equivalency of 0.5 mm, and under-table drapes of 70×116 cm and 65×70 cm in the newer and the older room respectively. Themore » larger skirt can be wrapped around the table’s corner and in addition the newer suite had two upper shields of 25×55 cm and 25×35 cm. The patient was simulated by 30 cm of acrylic, air kerma rate (AKR) was measured with the 180cc ionization chamber (AccuPro Radcal Corporation, Monrovia, CA, USA) at different positions. The ancillary shields, x-ray tube, image detector, and table height were adjusted by the IR radiologist to simulate various clinical setups. The same exposure parameters were used for all acquisitions. AKR measurements were made at different positions relative to the operator. Results: The AKR measurements demonstrated 91–99% x-ray attenuation by the drapes in both suites. The smaller size of the under-table skirt and absence of the side-drapes in the older room resulted in a 20–50 fold increase of scattered radiation to the operator. The mobile suspended lead-acrylic shield reduced AKR by 90–94% measured at 150–170 cm height. The recommendations were made to replace the smaller under-table skirt and to use the ceiling-mounted shields for all IR procedures. Conclusion: The ancillary shielding may significantly affect radiation exposure to the IR staff. The use of suspended ceiling-mounted shields is especially important for reduction of interventional radiologists’ cranial radiation.« less

  3. Local shock-wave lithotripsy of distal ureteral calculi.

    PubMed

    Voges, G E; Wilbert, D M; Stöckle, M; Hohenfellner, R

    1988-01-01

    Since the initiation of the clinical trial utilizing a second-generation lithotripor (Lithostar, Siemens, Erlangen, FRG), 96 patients with distal ureteral calculi (i.e. calculi below the pelvic brim) underwent local shock-wave lithotripsy. Routine treatment was conducted under intravenous sedation and light analgesia only. Complete stone disintegration was achieved in 84 patients (87.5%), 11 requiring two sessions and 1 patient, three. In 7 patients ureteroscopy became necessary after unsuccessful local shock-wave treatment. In 2 of these patients a 9-french flexible ureteroscope and the Storz Q-switched neodymium-YAG laser was used for stone disintegration. In 3 cases loop extraction and in 2 cases open surgery had to be performed for definitive stone removal. All pre- and postoperative manipulations (except open surgery) were done on the Lithostar. Local shock-wave lithotripsy is a highly successful, noninvasive, time-saving and easily applicable technique. It has become our primary approach in the treatment of distal ureteral calculi.

  4. Computed Tomography and Magnetic Resonance Anatomy of the Normal Orbit and Eye of the Horse.

    PubMed

    D'Août, C; Nisolle, J F; Navez, M; Perrin, R; Launois, T; Brogniez, L; Clegg, P; Hontoir, F; Vandeweerd, J M

    2015-10-01

    Traumatic and infectious diseases of the eye and orbit can occur in horses. For diagnosis and monitoring of such diseases, medical imaging is useful including computed tomography (CT) and magnetic resonance imaging (MRI). The aim of the current study was to describe CT and MRI anatomy of the equine orbit and ocular globe. The heads from four adult horses were scanned with a 6-slice Emotion 6 CT (Siemens, Erlangen), and a 3.0 Tesla Siemens Verio 6 MRI using T1 and T2-weighted sequences. To validate CT and MR reference images, these were compared with anatomical models and gross anatomical sections. The bony limits of the orbital cavity, the relationship of the orbit with sinuses and foramina of the skull were well identified by CT. MRI was useful to observe soft tissues and was able to identify adnexae of the ocular globe (eyelids, periorbital fat, extraocular muscles, lacrymal and tarsal glands). Although MRI was able to identify all components of the eye (including the posterior chamber), it could not differentiate sclera from choroid and retina. The only nerve identified was the optic nerve. Vessels were not seen in this series of cadaver heads. This study showed that CT and MRI are useful techniques to image the equine orbit and eye that can have clinical applications. © 2014 Blackwell Verlag GmbH.

  5. Determination of facial symmetry in unilateral cleft lip and palate patients from three-dimensional data: technical report and assessment of measurement errors.

    PubMed

    Nkenke, Emeka; Lehner, Bernhard; Kramer, Manuel; Haeusler, Gerd; Benz, Stefanie; Schuster, Maria; Neukam, Friedrich W; Vairaktaris, Eleftherios G; Wurm, Jochen

    2006-03-01

    To assess measurement errors of a novel technique for the three-dimensional determination of the degree of facial symmetry in patients suffering from unilateral cleft lip and palate malformations. Technical report, reliability study. Cleft Lip and Palate Center of the University of Erlangen-Nuremberg, Erlangen, Germany. The three-dimensional facial surface data of five 10-year-old unilateral cleft lip and palate patients were subjected to the analysis. Distances, angles, surface areas, and volumes were assessed twice. Calculations were made for method error, intraclass correlation coefficient, and repeatability of the measurements of distances, angles, surface areas, and volumes. The method errors were less than 1 mm for distances and less than 1.5 degrees for angles. The intraclass correlation coefficients showed values greater than .90 for all parameters. The repeatability values were comparable for cleft and noncleft sides. The small method errors, high intraclass correlation coefficients, and comparable repeatability values for cleft and noncleft sides reveal that the new technique is appropriate for clinical use.

  6. Compositional variations and differential diagenesis in Miocene turbidites from the western coast of Mallorca (Balearic Islands, Spain)

    NASA Astrophysics Data System (ADS)

    Felder, Sonja; Westphal, Hildegard; Munnecke, Axel; Mateu Vicens, Guillem

    2010-05-01

    Compositional variations and differential diagenesis in Miocene turbidites from the western coast of Mallorca (Balearic Islands, Spain) Sonja Felder (1), Hildegard Westphal (1), Axel Munnecke (2), Guillem Mateu Vicens (1,3) (1) MARUM and Department of Geosciences, Universität Bremen, Leobener Straße, 28359 Bremen, Germany (2) GeoZentrum Nordbayern, Universität Erlangen-Nürnberg, Loewenichstr. 28, 91054 Erlangen, Germany (3) Dipartimento di Scienze della Terra, Università di Roma "La Sapienza", Ple Aldo 7 Moro, 5. I-00185 Roma, Italy Cyclic alternations of limestone and marl beds crop out along the western coast of the Island of Mallorca. This Miocene succession is traditionally interpreted to represent more weathering-resistant turbidites interlayered by softer hemipelagic background sediment. However, the cementation patterns that dominate the appearance of the outcrop do not always consistently follow sedimentary layering; locally the cemented beds are systematically oblique to the sedimentary layers. Compositional studies demonstrate that differences in non-carbonate fraction, carbonate concentration and fossil content (e.g. foraminiferal assemblages) trace sedimentary bedding, regardless the diagenetic style. Limestone versus marl lithology, in contrast, is defined by the diagenetic style, tight cementation by calcite cements in the limestones versus low porosity and compaction in the marls. The reason for this striking pattern of diagenetic bedding cross-cutting sedimentary layers is assumed to be related to tectonic fracturing, opening pathways for diagenetic fluids. This example cautions the straight-forward interpretation of limestone-marl alternations as direct witnesses of environmental or climatic variations.

  7. Analysis of the interface and data transfer from ICU to normal wards in a German University Hospital.

    PubMed

    Vollmer, Anne-Maria; Skonetzki-Cheng, Stefan; Prokosch, Hans-Ulrich

    2013-01-01

    Typically general wards and intensive care units (ICU) have very different labor organizations, structures and IT-systems in Germany. There is a need for coordination, because of the different working arrangements. Our team investigated the interface between ICU and general ward and especially the respective information transfer in the University hospital in Erlangen (Bavaria, Germany). The research team used a combination of interviews, observations and the analysis of transfer records and forms as part of a methodical triangulation. We identified 41 topics, which are discussed or presented in writing during the handover. In a second step, we investigate the requirements of data transmission in expert interviews. A data transfer concept from the perspective of the nurses and physicians was developed and we formulated recommendations for improvements of process and communication for this interface. Finally the data transfer concept was evaluated by the respondents.

  8. Interprofessional education in Erlangen: A needs analysis and the conceptual work of a student working group.

    PubMed

    Konietzko, Raffael; Frank, Luca; Maudanz, Nils; Binder, Johannes

    2016-01-01

    Interprofessional education (IPE) is receiving growing significance both nationally and internationally. Despite this, organizational and curricular changes are posing challenges. The level of need for IPE and how changes can be made to curricula and infrastructure were investigated at the University of Erlangen in Germany. The student working group for interprofessional teaching (AGIL) has turned its attention to these issues. This group is composed of students from medicine, dentistry, molecular medicine, medical technology and speech therapy. In June, 2015, a needs analysis was carried out among the students in the study programs represented in the working group to assess the actual and target situation concerning IPE (n=1,105). In the search for answers and to better measure any needs, contact was sought with instructors. The majority of students feel that they are insufficiently educated in terms of interprofessional skills. A large proportion of the students wish to see expansion of the IPE offerings. Students also expressed a desire for additional spaces and welcomed the idea of an interprofessional learning center. AGIL began establishing interprofessional electives in October 2015. A concept for an interprofessional learning center was developed. Based on the survey results, a need for improvements to curricula and infrastructure can be seen; however, the results are limited to the student point of view. AGIL would like to establish more interprofessional electives. These courses would then facilitate curricular implementation. Modern ideas about study environments could be applied to IPE, in particular to promote informal forms of learning. Contact with instructors was crucial for the project work and should be expanded. Realizing and financing the learning center in Erlangen are now the future goals of AGIL. The aim is to create a foundation for this purpose.

  9. Direct cooling of the catheter tip increases safety for CMR-guided electrophysiological procedures

    PubMed Central

    2012-01-01

    Background One of the safety concerns when performing electrophysiological (EP) procedures under magnetic resonance (MR) guidance is the risk of passive tissue heating due to the EP catheter being exposed to the radiofrequency (RF) field of the RF transmitting body coil. Ablation procedures that use catheters with irrigated tips are well established therapeutic options for the treatment of cardiac arrhythmias and when used in a modified mode might offer an additional system for suppressing passive catheter heating. Methods A two-step approach was chosen. Firstly, tests on passive catheter heating were performed in a 1.5 T Avanto system (Siemens Healthcare Sector, Erlangen, Germany) using a ASTM Phantom in order to determine a possible maximum temperature rise. Secondly, a phantom was designed for simulation of the interface between blood and the vascular wall. The MR-RF induced temperature rise was simulated by catheter tip heating via a standard ablation generator. Power levels from 1 to 6 W were selected. Ablation duration was 120 s with no tip irrigation during the first 60 s and irrigation at rates from 2 ml/min to 35 ml/min for the remaining 60 s (Biotronik Qiona Pump, Berlin, Germany). The temperature was measured with fluoroscopic sensors (Luxtron, Santa Barbara, CA, USA) at a distance of 0 mm, 2 mm, 4 mm, and 6 mm from the catheter tip. Results A maximum temperature rise of 22.4°C at the catheter tip was documented in the MR scanner. This temperature rise is equivalent to the heating effect of an ablator's power output of 6 W at a contact force of the weight of 90 g (0.883 N). The catheter tip irrigation was able to limit the temperature rise to less than 2°C for the majority of examined power levels, and for all examined power levels the residual temperature rise was less than 8°C. Conclusion Up to a maximum of 22.4°C, the temperature rise at the tissue surface can be entirely suppressed by using the catheter's own irrigation system. The irrigated tip system can be used to increase MR safety of EP catheters by suppressing the effects of unwanted passive catheter heating due to RF exposure from the MR scanner. PMID:22296883

  10. Concepts for dose determination in flat-detector CT

    NASA Astrophysics Data System (ADS)

    Kyriakou, Yiannis; Deak, Paul; Langner, Oliver; Kalender, Willi A.

    2008-07-01

    Flat-detector computed tomography (FD-CT) scanners provide large irradiation fields of typically 200 mm in the cranio-caudal direction. In consequence, dose assessment according to the current definition of the computed tomography dose index CTDIL=100 mm, where L is the integration length, would demand larger ionization chambers and phantoms which do not appear practical. We investigated the usefulness of the CTDI concept and practical dosimetry approaches for FD-CT by measurements and Monte Carlo (MC) simulations. An MC simulation tool (ImpactMC, VAMP GmbH, Erlangen, Germany) was used to assess the dose characteristics and was calibrated with measurements of air kerma. For validation purposes measurements were performed on an Axiom Artis C-arm system (Siemens Medical Solutions, Forchheim, Germany) equipped with a flat detector of 40 cm × 30 cm. The dose was assessed for 70 kV and 125 kV in cylindrical PMMA phantoms of 160 mm and 320 mm diameter with a varying phantom length from 150 to 900 mm. MC simulation results were compared to the values obtained with a calibrated ionization chambers of 100 mm and 250 mm length and to thermoluminesence (TLD) dose profiles. The MCs simulations were used to calculate the efficiency of the CTDIL determination with respect to the desired CTDI∞. Both the MC simulation results and the dose distributions obtained by MC simulation were in very good agreement with the CTDI measurements and with the reference TLD profiles, respectively, to within 5%. Standard CTDI phantoms which have a z-extent of 150 mm underestimate the dose at the center by up to 55%, whereas a z-extent of >=600 mm appears to be sufficient for FD-CT; the baseline value of the respective profile was within 1% to the reference baseline. As expected, the measurements with ionization chambers of 100 mm and 250 mm offer a limited accuracy, whereas an increased integration length of >=600 mm appeared to be necessary to approximate CTDI∞ in within 1%. MC simulations appear to offer a practical and accurate way of assessing conversion factors for arbitrary dosimetry setups using a standard pencil chamber to provide estimates of CTDI∞. This would eliminate the need for extra-long phantoms and ionization chambers or excessive amounts of TLDs.

  11. Can a single isotropic 3D fast spin echo sequence replace three-plane standard proton density fat-saturated knee MRI at 1.5 T?

    PubMed Central

    Robinson, P; Hodgson, R; Grainger, A J

    2015-01-01

    Objective: To assess whether a single isotropic three-dimensional (3D) fast spin echo (FSE) proton density fat-saturated (PD FS) sequence reconstructed in three planes could replace the three PD (FS) sequences in our standard protocol at 1.5 T (Siemens Avanto, Erlangen, Germany). Methods: A 3D FSE PD water excitation sequence was included in the protocol for 95 consecutive patients referred for routine knee MRI. This was used to produce offline reconstructions in axial, sagittal and coronal planes. Two radiologists independently assessed each case twice, once using the standard MRI protocol and once replacing the standard PD (FS) sequences with reconstructions from the 3D data set. Following scoring, the observer reviewed the 3D data set and performed multiplanar reformats to see if this altered confidence. The menisci, ligaments and cartilage were assessed, and statistical analysis was performed using the standard sequence as the reference standard. Results: The reporting accuracy was as follows: medial meniscus (MM) = 90.9%, lateral meniscus (LM) = 93.7%, anterior cruciate ligament (ACL) = 98.9% and cartilage surfaces = 85.8%. Agreement among the readers was for the standard protocol: MM kappa = 0.91, LM = 0.89, ACL = 0.98 and cartilage = 0.84; and for the 3D protocol: MM = 0.86, LM = 0.77, ACL = 0.94 and cartilage = 0.64. Conclusion: A 3D PD FSE sequence reconstructed in three planes gives reduced accuracy and decreased concordance among readers compared with conventional sequences when evaluating the menisci and cartilage with a 1.5-T MRI scanner. Advances in knowledge: Using the existing 1.5-T MR systems, a 3D FSE sequence should not replace two-dimensional sequences. PMID:26067920

  12. Time-Dependent Changes in T1 during Fracture Healing in Juvenile Rats: A Quantitative MR Approach

    PubMed Central

    Baron, Katharina; Neumayer, Bernhard; Amerstorfer, Eva; Scheurer, Eva; Diwoky, Clemens; Stollberger, Rudolf; Sprenger, Hanna; Weinberg, Annelie M.

    2016-01-01

    Quantitative magnetic resonance imaging (qMRI) offers several advantages in imaging and determination of soft tissue alterations when compared to qualitative imaging techniques. Although applications in brain and muscle tissues are well studied, its suitability to quantify relaxation times of intact and injured bone tissue, especially in children, is widely unknown. The objective observation of a fracture including its age determination can become of legal interest in cases of child abuse or maltreatment. Therefore, the aim of this study is the determination of time dependent changes in intact and corresponding injured bones in immature rats via qMRI, to provide the basis for an objective and radiation-free approach for fracture dating. Thirty-five MR scans of 7 Sprague-Dawley rats (male, 4 weeks old, 100 ± 5 g) were acquired on a 3T MRI scanner (TimTrio, Siemens AG, Erlangen, Germany) after the surgical infliction of an epiphyseal fracture in the tibia. The images were taken at days 1, 3, 7, 14, 28, 42 and 82 post-surgery. A proton density-weighted and a T1-weighted 3D FLASH sequence were acquired to calculate the longitudinal relaxation time T1 of the fractured region and the surrounding tissues. The calculation of T1 in intact and injured bone resulted in a quantitative observation of bone development in intact juvenile tibiae as well as the bone healing process in the injured tibiae. In both areas, T1 decreased over time. To evaluate the differences in T1 behaviour between the intact and injured bone, the relative T1 values (bone-fracture) were calculated, showing clear detectable alterations of T1 after fracture occurrence. These results indicate that qMRI has a high potential not only for clinically relevant applications to detect growth defects or developmental alterations in juvenile bones, but also for forensically relevant applications such as the dating of fractures in cases of child abuse or maltreatment. PMID:27832068

  13. Transvaginal Aspiration of Ovarian Cysts: Long-Term Follow-up

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duke, D.; Colville, J.; Keeling, A.

    2006-06-15

    Background and purpose. Transvaginal aspiration of ovarian cysts has been advocated as a viable alternative to surgery in patients who are high-risk surgical candidates. We describe a retrospective study evaluating the results of transvaginal aspirations of benign ovarian cysts in patients at increased surgical risk, focusing on long-term follow-up for recurrence of the cyst and/or development of malignancy. Methods. Twenty-four women with ovarian cysts underwent 34 transvaginal drainages between October 1998 and December 2004. All patients were referred following diagnosis of a persistent ovarian cyst with a benign appearance on ultrasound. All patients were unsuitable candidates for surgery (history ofmore » previous pelvic surgery, n = 21; high risk for anesthesia, n = 1; and unsuitable for laparoscopy due to obesity, n = 2). Patients with a history of pregnancy, acute abdominal symptoms, or previous gynecologic malignancy were excluded. A 20G x 20 cm Chiba needle was used for transvaginal aspiration using an endocavity probe (Acuson XP, Mountain View, CA, USA; Siemens Sololine, Erlangen, Germany) and intravenous sedoanalgesia. Cysts were aspirated to dryness. Results. Long-term follow-up of patients was performed and revealed a recurrence rate of 75%. Eighty-three percent of cysts on the left and 42% of those on the right recurred. Nine of 15 (60%) patients with recurrence required further intervention. Two of 9 underwent surgical intervention only, 4 of 9 had repeat transvaginal aspiration(s) performed, and 3 of 9 had a combination of both transvaginal aspiration and surgery. No patient developed ovarian malignancy. Conclusion. Transvaginal cyst aspiration has many advantages including short hospital stay, rapid recovery, excellent patient tolerance, and a low rate of procedure-related complications. Our study demonstrates that ovarian cyst recurrence following transvaginal drainage is a more significant problem than previously documented, especially if the cyst is on the left side. However, when recurrences do occur, repeat transvaginal aspirations may be considered in the symptomatic patient.« less

  14. Detection of myocardial ischemia by automated, motion-corrected, color-encoded perfusion maps compared with visual analysis of adenosine stress cardiovascular magnetic resonance imaging at 3 T: a pilot study.

    PubMed

    Doesch, Christina; Papavassiliu, Theano; Michaely, Henrik J; Attenberger, Ulrike I; Glielmi, Christopher; Süselbeck, Tim; Fink, Christian; Borggrefe, Martin; Schoenberg, Stefan O

    2013-09-01

    The purpose of this study was to compare automated, motion-corrected, color-encoded (AMC) perfusion maps with qualitative visual analysis of adenosine stress cardiovascular magnetic resonance imaging for detection of flow-limiting stenoses. Myocardial perfusion measurements applying the standard adenosine stress imaging protocol and a saturation-recovery temporal generalized autocalibrating partially parallel acquisition (t-GRAPPA) turbo fast low angle shot (Turbo FLASH) magnetic resonance imaging sequence were performed in 25 patients using a 3.0-T MAGNETOM Skyra (Siemens Healthcare Sector, Erlangen, Germany). Perfusion studies were analyzed using AMC perfusion maps and qualitative visual analysis. Angiographically detected coronary artery (CA) stenoses greater than 75% or 50% or more with a myocardial perfusion reserve index less than 1.5 were considered as hemodynamically relevant. Diagnostic performance and time requirement for both methods were compared. Interobserver and intraobserver reliability were also assessed. A total of 29 CA stenoses were included in the analysis. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for detection of ischemia on a per-patient basis were comparable using the AMC perfusion maps compared to visual analysis. On a per-CA territory basis, the attribution of an ischemia to the respective vessel was facilitated using the AMC perfusion maps. Interobserver and intraobserver reliability were better for the AMC perfusion maps (concordance correlation coefficient, 0.94 and 0.93, respectively) compared to visual analysis (concordance correlation coefficient, 0.73 and 0.79, respectively). In addition, in comparison to visual analysis, the AMC perfusion maps were able to significantly reduce analysis time from 7.7 (3.1) to 3.2 (1.9) minutes (P < 0.0001). The AMC perfusion maps yielded a diagnostic performance on a per-patient and on a per-CA territory basis comparable with the visual analysis. Furthermore, this approach demonstrated higher interobserver and intraobserver reliability as well as a better time efficiency when compared to visual analysis.

  15. Accuracy of Phase-Contrast Velocity Mapping Proximal and Distal to Stent Artifact During Cardiac Magnetic Resonance Imaging.

    PubMed

    Avitabile, Catherine M; Harris, Matthew A; Doddasomayajula, Ravi S; Chopski, Steven G; Gillespie, Matthew J; Dori, Yoav; Glatz, Andrew C; Fogel, Mark A; Whitehead, Kevin K

    2018-06-15

    Little data are available on the accuracy of phase-contrast magnetic resonance imaging (PC-MRI) velocity mapping in the vicinity of intravascular metal stents other than nitinol stents. Therefore, we sought to determine this accuracy using in vitro experiments. An in vitro flow phantom was used with 3 stent types: (1) 316L stainless steel, (2) nitinol self-expanding, and (3) platinum-iridium. Steady and pulsatile flow was delivered with a magnetic resonance imaging-compatible pump (CardioFlow 5000, Shelley Medical, London, Ontario, Canada). Flows were measured using a transit time flow meter (ME13PXN, Transonic, Inc, Ithaca, New York). Mean flows ranged from 0.5 to 7 L/min. For each condition, 5 PC-MRI acquisitions were made: within the stent, immediately adjacent to both edges of the stent artifact, and 1 cm upstream and downstream of the artifact. Mean PC-MRI flows were calculated by segmenting the tube lumen using clinical software (ARGUS, Siemens, Inc, Erlangen, Germany). PC-MRI and flow meter flows were compared by location and stent type using linear regression, Bland-Altman, and intraclass correlation (ICC). PC-MRI flows within the stent artifact were inaccurate for all stents studied, generally underestimating flow meter-measured flow. Agreement between PC-MRI and flow meter-measured flows was excellent for all stent types, both immediately adjacent to and 1 cm away from the edge of the stent artifact. Agreement was highest for the platinum-iridium stent (R = 0.999, ICC = 0.999) and lowest for the nitinol stent (R = 0.993, ICC = 0.987). In conclusion, PC-MRI flows are highly accurate just upstream and downstream of a variety of clinically used stents, supporting its use to directly measure flows in stented vessels. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Comparison of Different Magnetic Resonance Cholangiography Techniques in Living Liver Donors Including Gd-EOB-DTPA Enhanced T1-Weighted Sequences

    PubMed Central

    Kinner, Sonja; Steinweg, Verena; Maderwald, Stefan; Radtke, Arnold; Sotiropoulos, Georgios; Forsting, Michael; Schroeder, Tobias

    2014-01-01

    Objectives Preoperative evaluation of potential living liver donors (PLLDs) includes the assessment of the biliary anatomy to avoid postoperative complications. Aim of this study was to compare T2-weighted (T2w) and Gd-EOB-DTPA enhanced T1-weighted (T1w) magnetic resonance cholangiography (MRC) techniques in the evaluation of PLLDs. Materials and Methods 30 PLLDs underwent MRC on a 1.5 T Magnetom Avanto (Siemens, Erlangen, Germany) using (A) 2D T2w HASTE (Half Fourier Acquisition Single Shot Turbo Spin Echo) fat saturated (fs) in axial plane, (B) 2D T2w HASTE fs thick slices in coronal plane, (C) free breathing 3D T2w TSE (turbo spin echo) RESTORE (high-resolution navigator corrected) plus (D) maximum intensity projections (MIPs), (E) T2w SPACE (sampling perfection with application optimized contrasts using different flip angle evolutions) plus (F) MIPs and (G) T2w TSE BLADE as well as Gd-EOB-DTPA T1w images without (G) and with (H) inversion recovery. Contrast enhanced CT cholangiography served as reference imaging modality. Two independent reviewers evaluated the biliary tract anatomy on a 5-point scale subjectively and objectively. Data sets were compared using a Mann-Whitney-U-test. Kappa values were also calculated. Results Source images and maximum intensity projections of 3D T2w TSE sequences (RESTORE and SPACE) proved to be best for subjective and objective evaluation directly followed by 2D HASTE sequences. Interobserver variabilities were good to excellent (k = 0.622–0.804). Conclusions 3D T2w sequences are essential for preoperative biliary tract evaluation in potential living liver donors. Furthermore, our results underline the value of different MRCP sequence types for the evaluation of the biliary anatomy in PLLDs including Gd-EOB-DTPA enhanced T1w MRC. PMID:25426932

  17. [Comparison of dignity determination of mammographic microcalcification with two systems for digital full-field mammography with different detector resolution: a retrospective clinical study].

    PubMed

    Schulz-Wendtland, R; Hermann, K-P; Adamietz, B; Meier-Meitinger, M; Wenkel, E; Lell, M; Anders, K; Uder, M

    2011-02-01

    The aim of this retrospective clinical study was to compare the diagnostic accuracy of the novel 50 µm FFDM (full-field digital mammography) system (DR) with an established 70 µm system (DR) in the differential diagnosis between benign and malignant clusters of microcalcification (n=50) (BI-RADS™ classification 4/5) and to assess the possible incremental value of the 50 µm pixel-pitch on specificity. From March 2009 to September 2009, 50 patients underwent full-field digital mammography (FFDM) (detector resolution 70 µm) (Novation, Siemens, Erlangen, Germany). As there were suspicious signs of microcalcification classified with BI-RADS™ 4/5 after diagnosis and preoperative wire localization, control images were made with the new FFDM system (detector: resolution 50 µm) (Amulet, Fujifilm, Tokyo, Japan) with the same exposure parameters. The diagnosis was determined after the operation by five radiologists with different experience in digital mammography from randomly distributed mediolateral views (monitor reading) whose results were correlated with the final histology of all lesions. Histopathology revealed 19 benign and 31 malignant lesions in 50 patients after open biopsy. The results of the five readers showed a higher sensitivity of the new FFDM system (80.0%) in the ability to recognize malignant microcalcification in comparison to the established system (74.8%). The specificity (75.8 versus 71.6%) was slightly higher for the new system but these results were not statistically significant (p<0.001). Considering the diagnostic accuracy, the new system (detector: resolution 50 µm) was also slightly superior to the well-known system (detector: resolution 70 µm) (80.1% versus 76.4%). Our study has shown that the new full-field digital mammography system using the novel detector compared with the already established FFDM system with respect to the assessment of microcalcification is at least equivalent.

  18. High Manifestations of Mental Distress in Arabic Asylum Seekers Accommodated in Collective Centers for Refugees in Germany

    PubMed Central

    Georgiadou, Ekaterini; Morawa, Eva; Erim, Yesim

    2017-01-01

    The number of asylum seekers in Germany has significantly increased in the last two years. Coming from regions of political conflict and war, the refugees have often experienced traumatic events which designate them as a high risk group for mental disorders. In a sample of Arabic speaking asylum seekers in collective accommodation centers in Erlangen, Germany, we estimated the extent of posttraumatic stress, depression, and anxiety. A further objective of the study was to test the comprehensibility and cultural appropriateness of the Arabic translations of the questionnaires in this sample. Between August and September 2016, 56 Arabic speaking asylum seekers placed among three collective accommodation centers in Erlangen completed self-report questionnaires assessing posttraumatic stress disorder (Essen Trauma-Inventory, ETI), and symptoms of depression (Patient Health Questionnaire—depression module, PHQ-9) and anxiety (Generalized Anxiety Disorder, GAD-7). The prevalence of participants with personally and/or witnessed traumatic events was 80.4% (n = 45). About one-third of the examinees (35.7%, n = 20) endorsed symptoms of PTSD (posttraumatic stress disorder). The total score for depression in this sample was M = 11.9 (SD = 7.9, range: 0–27). Moderate to severe depression (PHQ-9 score ≥ 15) was found in 35.7% (n = 20) of our sample and severe depression (PHQ-9 score ≥ 20) was found in 23.2% (n = 13). The total score for anxiety was M = 8.8 (SD = 6.9, range: 0–21), with 26.8% (n = 15) of the sample showing symptoms of severe anxiety (GAD-7 score ≥ 15). No significant difference between women and men with respect to frequency and symptom scores of PTSD, depression, and anxiety was found. Amongst asylum seekers of the presented sample, the rates of traumatic events as well as the prevalence of possible PTSD, depression, and anxiety were significantly higher than in the German population. This indicates that the refugee population is in need of culturally sensitive psychological interventions. However, more studies are required to improve the understanding of mental health among this particularly vulnerable population. PMID:28590438

  19. High-resolution ultrasonography in assessing temporomandibular joint disc position.

    PubMed

    Talmaceanu, Daniel; Lenghel, Lavinia Manuela; Bolog, Nicolae; Popa Stanila, Roxana; Buduru, Smaranda; Leucuta, Daniel Corneliu; Rotar, Horatiu; Baciut, Mihaela; Baciut, Grigore

    2018-02-04

    The purpose of this study was to determine the diagnostic value of high-resolution ultrasonography (US) in temporomandibular joint (TMJ) disc displacements. A number of 74 patients (148 TMJs) with signs and symptoms of TMJ disorders, according to the Research Diagnostic Criteria for Temporomandibular Disorders, were included in this study. All patients received US and magnetic resonance imaging (MRI) of both TMJs 1 to 5 days after the clinical examination. MRI examinations were performed using 1.5 T MRI equipment (Siemens Avanto, Siemens, Erlangen). Ultrasonographic examination was performed on a Hitachi EUB 8500 (Hitachi Medical Corp., Tokyo, Japan) scanner with L 54 M6.5-13 MHz linear transducer. MRI depicted 68 (45.95%) normal joints, 47 (31.76%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 34 (22.97%) with degenerative changes. US detected 78 (52.7%) normal joints, 37 (25%) with disc displacement with reduction, 33 (22.3%) with disc displacement without reduction and 21 (14.19%) with degenerative changes. Compared to MRI, US showed a sensitivity of 93.1%, specificity of 87.88%, accuracy of 90.32%, a positive predictive value of 87.1% and a negative predictive value of 93.55% for overall diagnosis of disc displacement. The Youden index was 0.81. Based on our results, high-resolution ultrasonography showed high sensitivity, specificity and accuracy in the diagnosis of TMJ disc displacement. It could be a valuable imaging technique in assessing TMJ disc position. The diagnostic value of high-resolution ultrasonography depends strictly on the examiner's skills and on the equipment used.

  20. Real-time magnetic resonance imaging of deep venous flow during muscular exercise-preliminary experience.

    PubMed

    Joseph, Arun Antony; Merboldt, Klaus-Dietmar; Voit, Dirk; Dahm, Johannes; Frahm, Jens

    2016-12-01

    The accurate assessment of peripheral venous flow is important for the early diagnosis and treatment of disorders such as deep-vein thrombosis (DVT) which is a major cause of post-thrombotic syndrome or even death due to pulmonary embolism. The aim of this work is to quantitatively determine blood flow in deep veins during rest and muscular exercise using a novel real-time magnetic resonance imaging (MRI) method for velocity-encoded phase-contrast (PC) MRI at high spatiotemporal resolution. Real-time PC MRI of eight healthy volunteers and one patient was performed at 3 Tesla (Prisma fit, Siemens, Erlangen, Germany) using a flexible 16-channel receive coil (Variety, NORAS, Hoechberg, Germany). Acquisitions were based on a highly undersampled radial FLASH sequence with image reconstruction by regularized nonlinear inversion at 0.5×0.5×6 mm 3 spatial resolution and 100 ms temporal resolution. Flow was assessed in two cross-sections of the lower leg at the level of the calf muscle and knee using a protocol of 10 s rest, 20 s flexion and extension of the foot, and 10 s rest. Quantitative analyses included through-plane flow in the right posterior tibial, right peroneal and popliteal vein (PC maps) as well as signal intensity changes due to flow and muscle movements (corresponding magnitude images). Real-time PC MRI successfully monitored the dynamics of venous flow at high spatiotemporal resolution and clearly demonstrated increased flow in deep veins in response to flexion and extension of the foot. In normal subjects, the maximum velocity (averaged across vessel lumen) during exercise was 9.4±5.7 cm·s -1 for the right peroneal vein, 8.5±4.6 cm·s -1 for the right posterior tibial vein and 17.8±5.8 cm·s -1 for the popliteal vein. The integrated flow volume per exercise (20 s) was 1.9, 1.6 and 50 mL (mean across subjects) for right peroneal, right posterior tibial and popliteal vein, respectively. A patient with DVT presented with peak flow velocities of only about 2 cm·s -1 during exercise and less than 1 cm·s -1 during rest. Real-time PC MRI emerges as a new tool for quantifying the dynamics of muscle-induced flow in deep veins. The method provides both signal intensity changes and velocity information for the assessment of blood flow and muscle movements. It now warrants extended clinical trials to patients with suspected thrombosis.

  1. Treatment efficacy and outcomes using a third generation shockwave lithotripter.

    PubMed

    Neisius, Andreas; Wöllner, Jens; Thomas, Christian; Roos, Frederik C; Brenner, Walburgis; Hampel, Christian; Preminger, Glenn M; Thüroff, Joachim W; Gillitzer, Rolf

    2013-11-01

    To evaluate the clinical efficiency of a third generation electromagnetic shock wave lithotripter, the Lithoskop(®) (Siemens, Erlangen, Germany), regarding outcomes, stone disintegration, retreatment and complication rates. To compare the results of the Lithoskop with other currently available systems and the reference standard lithotripter, the HM-3 (Dornier MedTech Europe GmbH, Wessling, Germany). We analysed the data from 183 patients, including 13 children, undergoing extracorporeal shock wave lithotripsy (ESWL) for renal and ureteric calculi collected from a prospectively populated database. Outcomes were assessed by plain abdominal film of kidney, ureter and bladder and renal ultrasonography for radiopaque and computerized tomography for radiolucent stones 1 day after treatment and after 3 months. We analysed stone size and location before and after treatment, stone disintegration rate, retreatment rate, stone-free and residual fragment rates after 3 months, along with auxiliary procedures and complications. The mean (range) patient age was 48.6 (1.3-81.4) years, including 13 children with a mean (range) age of 8.4 (1.3-16.7) years, and 77% of the patients were male. In all, 46% of the calculi were localized in the kidney and 54% in the ureter. Renal stones were localized in the upper, middle and lower calyx and in the renal pelvis in 9, 29, 30 and 32% of patients, respectively. Ureteric stones were localized in the upper, mid- and distal ureter in 29, 19 and 52% of patients, respectively. The median (range) stone size before ESWL was 10 (4-25) mm in the kidney and 8 (4-28) mm in the ureteric calculi. The overall stone-free rate after 3 months was 91% (88% for renal and 93% for ureteric calculi); the mean number of sessions to achieve these rates was 1.3. Stone-free rates and the required number of sessions were determined only by stone size. In 7.1% of the patients (n = 13) post-interventional auxiliary procedures were necessary. We observed one perirenal haematoma as a major complication (0.5%), but this did not require any further therapy. Clinical stone-free rates with the Lithoskop are high and similar to those of other available systems, including the reference standard HM-3 lithotripter. Retreatment and complication rates are low, supporting the use of ESWL as first-line therapy for urinary calculi <10 mm, independent of stone location. © 2013 The Authors. BJU International © 2013 BJU International.

  2. Machine-Assisted Translation in West Germany

    DTIC Science & Technology

    1977-03-04

    the Ger- man, English , French or Russian languages are recorded, where it is known that they have been used in translation or teaching assignments...German literary language encompasses about 300,000 words, English about 600,000, and the vocabulary of a person of average education is about...Terminology Recording and Evaluation Method ) was developed in the language service of the Siemens company in Munich as an aid for in-house application

  3. PREFACE: Loops 11: Non-Perturbative / Background Independent Quantum Gravity

    NASA Astrophysics Data System (ADS)

    Mena Marugán, Guillermo A.; Barbero G, J. Fernando; Garay, Luis J.; Villaseñor, Eduardo J. S.; Olmedo, Javier

    2012-05-01

    Loops 11 The international conference LOOPS'11 took place in Madrid from the 23-28 May 2011. It was hosted by the Instituto de Estructura de la Materia (IEM), which belongs to the Consejo Superior de Investigaciones Cientĺficas (CSIC). Like previous editions of the LOOPS meetings, it dealt with a wealth of state-of-the-art topics on Quantum Gravity, with special emphasis on non-perturbative background-independent approaches to spacetime quantization. The main topics addressed at the conference ranged from the foundations of Quantum Gravity to its phenomenological aspects. They encompassed different approaches to Loop Quantum Gravity and Cosmology, Polymer Quantization, Quantum Field Theory, Black Holes, and discrete approaches such as Dynamical Triangulations, amongst others. In addition, this edition celebrated the 25th anniversary of the introduction of the now well-known Ashtekar variables and the Wednesday morning session was devoted to this silver jubilee. The structure of the conference was designed to reflect the current state and future prospects of research on the different topics mentioned above. Plenary lectures that provided general background and the 'big picture' took place during the mornings, and the more specialised talks were distributed in parallel sessions during the evenings. To be more specific, Monday evening was devoted to Shape Dynamics and Phenomenology Derived from Quantum Gravity in Parallel Session A, and to Covariant Loop Quantum Gravity and Spin foams in Parallel Session B. Tuesday's three Parallel Sessions dealt with Black Hole Physics and Dynamical Triangulations (Session A), the continuation of Monday's session on Covariant Loop Quantum Gravity and Spin foams (Session B) and Foundations of Quantum Gravity (Session C). Finally, Thursday and Friday evenings were devoted to Loop Quantum Cosmology (Session A) and to Hamiltonian Loop Quantum Gravity (Session B). The result of the conference was very satisfactory and enlightening. Not only was it a showroom for the research currently being carried out by many groups throughout the world, but there was also a permanent look towards the future. During these days, the CSIC Campus witnessed many scientific conversations triggered by the interaction amongst the people and groups that participated in LOOPS'11 Madrid and which, in many cases, will crystallise into new results and advances in the field. The conference would not have been possible without the generous help of a number of national and international institutions. The organizers would like to acknowledge the financial support provided by the Spanish Ministry of Science and Innovation (Ministerio de Ciencia e Innovación), the Spanish Research Council, CSIC (Consejo Superior de Investigaciones Cientĺficas), The BBVA Foundation (Fundación BBVA), The CONSOLIDER-CPAN project, the Spanish Society for Gravitation and Relativity (SEGRE), The Universidad Carlos III of Madrid (UC3M), and the European Science Foundation (ESF). The ESF, through the Quantum Gravity and Quantum Geometry network, provided full support for a number of young participants that have contributed to these proceedings: Dario Benedetti (Albert Einstein Institute, Potsdam, Germany), Norbert Bodendorfer (Institute for Theoretical Physics III, FAU Erlangen Nürnberg, Germany), Mariam Bouhmadi López (CENTRA, Centro Multidisciplinar de Astrofĺsica, Lisbon), Timothy Budd (Institute for Theoretical Physics, Utrecht University, The Netherlands), Miguel Campiglia (Institute for Gravitation and the Cosmos, Penn State University, USA), Gianluca Delfino (School of Mathematical Sciences, University of Nottingham, UK), Maite Dupuis (Institute for Theoretical Physics III, FAU Erlangen Nürnberg, Germany), Michał Dziendzikowski (Institute of Theoretical Physics, Warsaw University, Poland), Muxin Han (Centre de Physique Théorique de Luminy, Marseille, France), Philipp Höhn (Institute for Theoretical Physics, Utrecht University, The Netherlands), Jacek Puchta (Centre de Physique Théorique de Luminy, Marseille, France), James Ryan (Albert Einstein Institute, Potsdam, Germany), Lorenzo Sindoni (Albert Einstein Institute, Golm, Germany), David Sloan (Institute for Theoretical Physics, Utrecht University, The Netherlands), Johannes Tambornino (Laboratoire de Physique, ENS Lyon, France), Andreas Thurn (Institute for Theoretical Physics III, FAU Erlangen Nürnberg, Germany), Francesca Vidotto (Laboratoire de Physique Subatomique et de Cosmologie, Grenoble, France), and Matteo Smerlak (Albert Einstein Institute, Golm, Germany). We would like to conclude this preamble by thanking all the attendants of the conference for their high and enthusiastic participation. The presence of a large number of past and present Loop Quantum Gravity practitioners, as well as a significant number of top researchers in other approaches to quantum gravity, provided ample opportunities for fruitful scientific exchanges and a very lively atmosphere. It is encouraging to see that, 25 years after the inception of Loop Quantum Gravity, there is a vibrant young community of researchers entering the field. Let us hope that, with their help, the quantization of general relativity can be successfully accomplished in the near future. The Editors Conference photograph

  4. [Tolerance of magnetic resonance imaging in children and adolescents performed in a 1.5 Tesla MR scanner with an open design].

    PubMed

    Adamietz, B; Cavallaro, A; Radkow, T; Alibek, S; Holter, W; Bautz, W A; Staatz, G

    2007-08-01

    To investigate the tolerance of MR examinations in children and adolescents performed in a 1.5 Tesla MR scanner with an expanded bore diameter. 163 patients, ages 4 to 25, underwent MR examinations in a 1.5 Tesla MR scanner with an open design (MAGNETOM Espree, Siemens, Erlangen, Germany), characterized by a compact length of 125 cm and an expanded 70 cm bore diameter. MR imaging of the brain was carried out in most cases (78.5 %), followed by examinations of the spinal canal (9.8 %), the extremities (9.2 %) and the neck (2.5 %). The patients were divided into four age groups and the success rate, motion artifacts and diagnostic quality of the MR examinations were assessed using a 3-grade scale. In 119 of 163 patients (73.0 %), MR examination was possible without any motion artifacts. With respect to the different age groups, 41.7 % of the 4 - 7-year-old children, 67.6 % of the 8 - 10-year-old children, 84.1 % of the 11 - 16-year-old children and 95.8 % of the patients older than 17 showed tolerance grade I without motion artifacts and excellent diagnostic image quality. In 39 of 163 children (23.9 %), the MR images showed moderate motion artifacts but had sufficient diagnostic quality. With regard to the different age groups, 52.8 % of the 4 - 7-year-old children, 26.5 % of the 8 - 10-year-old children, 15.9 % of the 11 - 16-year-old children and none of the patients older than 17 showed tolerance grade II with moderate motion artifacts and sufficient diagnostic image quality. In only 4 of 124 children < 10 years old and 1 child > 10 years old, the MR examination was not feasible and had to be repeated under sedation. Pediatric MR imaging using a 1.5 Tesla MR scanner with an open design can be conducted in children and adolescents with excellent acceptance. The failure rate of 3.0 % of cases for pediatric MR imaging is comparable to that of a conventional low-field open MR scanner.

  5. Contrast-enhanced transrectal ultrasound (CE-TRUS) with cadence-contrast pulse sequence (CPS) technology for the identification of prostate cancer.

    PubMed

    Seitz, Michael; Gratzke, Christian; Schlenker, Boris; Buchner, Alexander; Karl, Alexander; Roosen, Alexander; Singer, Bernhard B; Bastian, Patrick J; Ergün, Süleyman; Stief, Christian G; Reich, Oliver; Tilki, Derya

    2011-01-01

    Various imaging modalities, such as magnetic resonance imaging (MRI), have been assessed with regard to their value in the detection of prostate cancer (CaP). However, there is a need for less time-consuming and more cost effective procedures in urology. In order to determine the ability of contrast-enhanced transrectal ultrasound (CE-TRUS) to identify CaP, we investigated patients scheduled for radical prostatectomy for CaP and radical cystoprostatectomy for bladder cancer. Between May and August 2008, 35 consecutive patients with CaP and muscle-invasive bladder carcinoma were prospectively enrolled in this single center study. All patients underwent B-mode TRUS and CE-TRUS (Sequoia 512 unit with an endocavity probe EV8C4, 8 MHz; Siemens, Erlangen, Germany) by one investigator blinded to any clinical data before radical surgery. Contrast-enhanced images were obtained after intravenous infusion of a bolus (2.4 ml) of the contrast agent SonoVue (Bracco, Milan, Italy). Ultrasound findings (CE-TRUS and B-mode TRUS) were correlated with step-section histology. On a per-patient basis, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for detecting CaP with CE-TRUS were 71.0%, 50.0%, 91.7%, and 18.2%, respectively. In comparison with B-mode TRUS (sensitivity 45.2%, specificity 75.0%, PPV 93.3%, and NPV 18.0%), CE-TRUS performed significantly better (P=0.004, McNemar test). On a per-prostate-lobe basis sensitivity, specificity, PPV, and NPV were 69.0%, 33.3%, 83.3%, and 18.2%. CE-TRUS detected prostate cancer with a modest sensitivity and a high PPV in a selected patient cohort. Future randomized-controlled multicenter studies are needed to further validate the value of CE-TRUS in the detection of CaP. Based on our results, CE-TRUS may not be recommended as a routine procedure in the diagnosis of CaP at present. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Assessment of calcium scoring performance in cardiac computed tomography.

    PubMed

    Ulzheimer, Stefan; Kalender, Willi A

    2003-03-01

    Electron beam tomography (EBT) has been used for cardiac diagnosis and the quantitative assessment of coronary calcium since the late 1980s. The introduction of mechanical multi-slice spiral CT (MSCT) scanners with shorter rotation times opened new possibilities of cardiac imaging with conventional CT scanners. The purpose of this work was to qualitatively and quantitatively evaluate the performance for EBT and MSCT for the task of coronary artery calcium imaging as a function of acquisition protocol, heart rate, spiral reconstruction algorithm (where applicable) and calcium scoring method. A cardiac CT semi-anthropomorphic phantom was designed and manufactured for the investigation of all relevant image quality parameters in cardiac CT. This phantom includes various test objects, some of which can be moved within the anthropomorphic phantom in a manner that mimics realistic heart motion. These tools were used to qualitatively and quantitatively demonstrate the accuracy of coronary calcium imaging using typical protocols for an electron beam (Evolution C-150XP, Imatron, South San Francisco, Calif.) and a 0.5-s four-slice spiral CT scanner (Sensation 4, Siemens, Erlangen, Germany). A special focus was put on the method of quantifying coronary calcium, and three scoring systems were evaluated (Agatston, volume, and mass scoring). Good reproducibility in coronary calcium scoring is always the result of a combination of high temporal and spatial resolution; consequently, thin-slice protocols in combination with retrospective gating on MSCT scanners yielded the best results. The Agatston score was found to be the least reproducible scoring method. The hydroxyapatite mass, being better reproducible and comparable on different scanners and being a physical quantitative measure, appears to be the method of choice for future clinical studies. The hydroxyapatite mass is highly correlated to the Agatston score. The introduced phantoms can be used to quantitatively assess the performance characteristics of, for example, different scanners, reconstruction algorithms, and quantification methods in cardiac CT. This is especially important for quantitative tasks, such as the determination of the amount of calcium in the coronary arteries, to achieve high and constant quality in this field.

  7. Level of Education as a Risk Factor for Extensive Prevalence of Cervical Intervertebral Disc Degenerative Changes and Chronic Neck Pain.

    PubMed

    Markotić, Vedran; Zubac, Damir; Miljko, Miro; Šimić, Goran; Zalihić, Amra; Bogdan, Gojko; Radančević, Dorijan; Šimić, Ana Dugandžić; Mašković, Josip

    2017-09-01

    The aim of this study was to document the prevalence of degenerative intervertebral disc changes in the patients who previously reported symptoms of neck pain and to determine the influence of education level on degenerative intervertebral disc changes and subsequent chronic neck pain. One hundred and twelve patients were randomly selected from the University Hospital in Mostar, Bosna and Herzegovina, (aged 48.5±12.7 years) and submitted to magnetic resonance imaging (MRI) of the cervical spine. MRI of 3.0 T (Siemens, Skyrim, Erlangen, Germany) was used to obtain cervical spine images. Patients were separated into two groups based on their education level: low education level (LLE) and high education level (HLE). Pfirrmann classification was used to document intervertebral disc degeneration, while self-reported chronic neck pain was evaluated using the previously validated Oswestry questionnaire. The entire logistic regression model containing all predictors was statistically significant, (χ 2 (3)=12.2, p=0.02), and was able to distinguish between respondents who had chronic neck pain and vice versa. The model explained between 10.0% (Cox-Snell R 2 ) and 13.8% (Nagelkerke R 2 ) of common variance with Pfirrmann classification, and it had the strength to discriminate and correctly classify 69.6% of patients. The probability of a patient being classified in the high or low group of degenerative disc changes according to the Pfirrmann scale was associated with the education level (Wald test: 5.5, p=0.02). Based on the Pfirrmann assessment scale, the HLE group was significantly different from the LLE group in the degree of degenerative changes of the cervical intervertebral discs (U=1,077.5, p=0.001). A moderate level of intervertebral disc degenerative changes (grade II and III) was equally matched among all patients, while the overall results suggest a higher level of education as a risk factor leading to cervical disc degenerative changes, regardless of age differences among respondents. Copyright© by the National Institute of Public Health, Prague 2017

  8. Quantitative and Qualitative Assessment of Yttrium-90 PET/CT Imaging

    PubMed Central

    Büsing, Karen-Anett; Schönberg, Stefan O.; Bailey, Dale L.; Willowson, Kathy; Glatting, Gerhard

    2014-01-01

    Yttrium-90 is known to have a low positron emission decay of 32 ppm that may allow for personalized dosimetry of liver cancer therapy with 90Y labeled microspheres. The aim of this work was to image and quantify 90Y so that accurate predictions of the absorbed dose can be made. The measurements were performed within the QUEST study (University of Sydney, and Sirtex Medical, Australia). A NEMA IEC body phantom containing 6 fillable spheres (10–37 mm ∅) was used to measure the 90Y distribution with a Biograph mCT PET/CT (Siemens, Erlangen, Germany) with time-of-flight (TOF) acquisition. A sphere to background ratio of 8∶1, with a total 90Y activity of 3 GBq was used. Measurements were performed for one week (0, 3, 5 and 7 d). he acquisition protocol consisted of 30 min-2 bed positions and 120 min-single bed position. mages were reconstructed with 3D ordered subset expectation maximization (OSEM) and point spread function (PSF) for iteration numbers of 1–12 with 21 (TOF) and 24 (non-TOF) subsets and CT based attenuation and scatter correction. Convergence of algorithms and activity recovery was assessed based on regions-of-interest (ROI) analysis of the background (100 voxels), spheres (4 voxels) and the central low density insert (25 voxels). For the largest sphere, the recovery coefficient (RC) values for the 30 min –2-bed position, 30 min-single bed and 120 min-single bed were 1.12±0.20, 1.14±0.13, 0.97±0.07 respectively. For the smaller diameter spheres, the PSF algorithm with TOF and single bed acquisition provided a comparatively better activity recovery. Quantification of Y-90 using Biograph mCT PET/CT is possible with a reasonable accuracy, the limitations being the size of the lesion and the activity concentration present. At this stage, based on our study, it seems advantageous to use different protocols depending on the size of the lesion. PMID:25369020

  9. Correlation of Point Shear Wave Velocity and Kidney Function in Chronic Kidney Disease.

    PubMed

    Grosu, Iulia; Bob, Flaviu; Sporea, Ioan; Popescu, Alina; Şirli, Roxana; Schiller, Adalbert

    2018-04-24

    Point shear wave elastography is a quantitative ultrasound-based imaging method used in the assessment of renal disease. Among point shear wave elastographic options, 2 techniques have been studied considerably: Virtual Touch quantification (VTQ; Siemens AG, Erlangen, Germany) and ElastPQ (EPQ; Philips Healthcare, Bothell, WA). Both rely on the tissue response to an acoustic beam generated by the ultrasound transducer. The data on renal VTQ are more extensive, whereas EPQ has been used less thus far in the assessment of the kidneys. This study aimed to evaluate the performance of EPQ in the kidney and compare it with VTQ. We studied 124 participants using EPQ: 22 with no renal disease and 102 with chronic kidney disease (CKD). Ninety-one were studied with both the EPQ and VTQ methods. We obtained 5 valid measurements in each kidney, expressed in meters per second. The mean kidney stiffness measurements ± SD obtained with EPQ in the healthy control group were as follows: right kidney, 1.23 ± 0.33 m/s; and left kidney, 1.26 ± 0.32 m/s (P = .6). In the patients with CKD (all stages), the mean kidney stiffness measurements obtained were significantly lower: right kidney, 1.09 ± 0.39 m/s; and left kidney, 1.04 ± 0.38 m/s (P = .4). We observed that, similar to VTQ, EPQ values decreased with CKD progression, based on analysis of variance results using different CKD stages. From a receiver operating characteristic curve analysis, the cutoff value for an estimated glomerular filtration rate of less than 45 mL/min was 1.24 m/s, and the value for an estimated glomerular filtration rate of less than 30 mL/min was 1.07 m/s. When using EPQ, the kidney shear wave velocity is decreased in patients with CKD, an observation similar to that obtained by using the VTQ method. © 2018 by the American Institute of Ultrasound in Medicine.

  10. SU-E-J-235: Audiovisual Biofeedback Improves the Correlation Between Internal and External Respiratory Motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, D; Pollock, S; Keall, P

    Purpose: External respiratory surrogates are often used to predict internal lung tumor motion for beam gating but the assumption of correlation between external and internal surrogates is not always verified resulting in amplitude mismatch and time shift. To test the hypothesis that audiovisual (AV) biofeedback improves the correlation between internal and external respiratory motion, in order to improve the accuracy of respiratory-gated treatments for lung cancer radiotherapy. Methods: In nine lung cancer patients, 2D coronal and sagittal cine-MR images were acquired across two MRI sessions (pre- and mid-treatment) with (1) free breathing (FB) and (2) AV biofeedback. External anterior-posterior (AP)more » respiratory motions of (a) chest and (b) abdomen were simultaneously acquired with physiological measurement unit (PMU, 3T Skyra, Siemens Healthcare Erlangen, Germany) and real-time position management (RPM) system (Varian, Palo Alto, USA), respectively. Internal superior-inferior (SI) respiratory motions of (c) lung tumor (i.e. centroid of auto-segmented lung tumor) and (d) diaphragm (i.e. upper liver dome) were measured from individual cine-MR images across 32 dataset. The four respiratory motions were then synchronized with the cine-MR image acquisition time. Correlation coefficients were calculated in the time variation of two nominated respiratory motions: (1) chest-abdomen, (2) abdomen-diaphragm and (3) diaphragm-lung tumor. The three combinations were compared between FB and AV biofeedback. Results: Compared to FB, AV biofeedback improved chest-abdomen correlation by 17% (p=0.005) from 0.75±0.23 to 0.90±0.05 and abdomen-diaphragm correlation by 4% (p=0.058) from 0.91±0.11 to 0.95±0.05. Compared to FB, AV biofeedback improved diaphragm-lung tumor correlation by 12% (p=0.023) from 0.65±0.21 to 0.74±0.16. Conclusions: Our results demonstrated that AV biofeedback significantly improved the correlation of internal and external respiratory motion, thus suggesting the need of AV biofeedback in respiratory-gated treatments.« less

  11. Cluster optical coding: from biochips to counterfeit security

    NASA Astrophysics Data System (ADS)

    Haglmueller, Jakob; Alguel, Yilmaz; Mayer, Christian; Matyushin, Viacheslav; Bauer, Georg; Pittner, Fritz; Leitner, Alfred; Aussenegg, Franz R.; Schalkhammer, Thomas G.

    2004-07-01

    Spatially tuned resonant nano-clusters allow high local field enhancement when exited by electromagnetic radiation. A number of phenomena had been described and subsequently applied to novel nano- and bionano-devices. Decisive for these types of devices and sensors is the precise nanometric assembly, coupling the local field surrounding a cluster to allow resonance with other elements interacting with this field. In particular, the distance cluster-mirror or cluster-fluorophore gives rise to a variety of enhancement phenomena. High throughput transducers using metal cluster resonance technology are based on surface-enhancement of metal cluster light absorption (SEA). The optical property for the analytical application of metal cluster films is the so-called anomalous absorption. At a well defined nanometric distance of a cluster to a mirror the reflected electromagnetic field has the same phase at the position of the absorbing cluster as the incident fields. This feedback mechanism strongly enhances the effective cluster absorption coefficient. The system is characterised by a narrow reflection minimum. Based on this SEA-phenomenon (licensed to and further developed and optimized by NovemberAG, Germany Erlangen) a number of commercial products have been constructed. Brandsealing(R) uses the patented SEA cluster technology to produce optical codings. Cluster SEA thin film systems show a characteristic color-flip effect and are extremely mechanically and thermally robust. This is the basis for its application as an unique security feature. The specific spectroscopic properties as e.g. narrow band multi-resonance of the cluster layers allow the authentication of the optical code which can be easily achieved with a mobile hand-held reader developed by november AG and Siemens AG. Thus, these features are machine-readable which makes them superior to comparable technologies. Cluster labels are available in two formats: as a label for tamper-proof product packaging, and as a direct label, where label and logo are permanently applied directly and unremovable to the product surface. Together with Infineon Technologies and HUECK FOLIEN, the SEA technology is currently developed as a direct label for e.g. SmartCards.

  12. SU-F-I-75: Half-Value Layer Thicknesses and Homogeneity Coefficients for Fluoroscopic X-Ray Beam Spectra Incorporating Spectral Filtration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wunderle, K; Wayne State University School of Medicine, Detroit, MI; Godley, A

    Purpose: The purpose of this investigation is to quantify various first half-value-layers (HVLs), second HVLs and homogeneity coefficients (HCs) for a state-of-the-art fluoroscope utilizing spectral (copper) filtration. Methods: A Radcal (Monrovia, Ca) AccuPro dosimeter with a 10×6-6 calibrated ionization chamber was used to measure air kerma for radiographic x-ray exposures made on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope operated in the service mode. The ionization chamber was centered in the x-ray beam at 72 cm from the focal spot with a source-to-image-distance of 120 cm. The collimators were introduced to limit the x-ray field to approximately 5 cm ×more » 5 cm at the ionization chamber plane. Type-1100 aluminum filters, in 0.5 mm increments, were used to determine the HVL. Two HVL calculation methods were used, log-linear interpolation and Lambert-W interpolation as described by Mathieu [Med Phys, 38(8), 4546 (2011)]. Multiple measurements were made at 60, 80, 100, 120 kVp at spectral filtration thicknesses of 0, 0.1, 0.3, 0.6 and 0.9 mm. Results: First HVL, second HVL, and HCs are presented for the fluoroscopic x-ray beam spectra indicated above, with nearly identical results from the two interpolation methods. Accuracy of the set kVp was also determined and deviated less than 2%. First HVLs for fluoroscopic x-ray beam spectra without spectral filtration determined in our study were 7%–16% greater than previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. However, the FDA minimum HVL requirements changed since that publication, requiring larger HVLs as of 2006. Additionally, x-ray tube and generator architecture have substantially changed over the last 15 years providing different beam spectra. Conclusion: X-ray beam quality characteristics for state-of-the-art fluoroscopes with spectral filtration have not been published. This study provides reference data which will be useful for defining beam qualities encountered on fluoroscopes using spectral filtration.« less

  13. Risk of radiation induced cataracts: investigation of radiation exposure to the eye lens during endourologic procedures.

    PubMed

    Hartmann, Josefin; Distler, Florian A; Baumueller, Martin; Guni, Ewald; Pahernik, Sascha A; Wucherer, Michael

    2018-06-14

    Due to new radiobiological data, the ICRP recommends a dose limit of 20mSv per year to the eye lens. Therefore, the IAEA International Basic Safety Standard and the EU council directive 2013/59/EURATOM requires a reduction of the annual dose limit from 150mSv to 20mSv. Urologists are exposed to an elevated radiation exposure in the head region during fluoroscopic interventions, due to the commonly used overtable X-ray tubes and the rarely used radiation protection for the head. Aim of the study was to analyze real radiation exposure to the eye lens of the urologist during various interventions during which the patient is in the lithotomy position. The partial body doses (forehead and apron collar) of the urologists and surgical staff were measured over a period of two months. 95 interventions were performed on Uroskop Omnia Max workplaces (Siemens Healthineers, Erlangen, Germany). Interventions were class-divided in less (stage I) and more complex (stage II) interventions. Two dosimeter-types were applied: well-calibrated electronic personal dosimeter EPD Mk2 and self-calibrated TLD-100H (both Thermo Fisher Scientific, Waltham, USA). The radiation exposure parameters were documented using the dose area product (DAP) and the fluoroscopy time (FT). The correlation between DAP and the apron dose of the urologist was in average 0.07µSv per 1µGym². The more experienced urologists yielded a mean DAP of 166µGym² for stage I and 415µGym² for stage II procedures. The interventionist was exposed with 10µSv in mean outside the lead apron collar. The mean dose value of the eye lenses per intervention was ascertained to 20µSv (mean DAP: 233µGym²). The study setup allows a differentiated and time-resolved measurement of the radiation exposure, which was found heterogeneous depending on intervention and surgeon. In this setting, approximately 1000 interventions can be performed until the annual eye lens dose limit is achieved.

  14. Characteristics of flattening filter free beams at low monitor unit settings.

    PubMed

    Akino, Yuichi; Ota, Seiichi; Inoue, Shinichi; Mizuno, Hirokazu; Sumida, Iori; Yoshioka, Yasuo; Isohashi, Fumiaki; Ogawa, Kazuhiko

    2013-11-01

    Newer linear accelerators (linacs) have been equipped to deliver flattening filter free (FFF) beams. When FFF beams are used for step-and-shoot intensity-modulated radiotherapy (IMRT), the stability of delivery of small numbers of monitor units (MU) is important. The authors developed automatic measurement techniques to evaluate the stability of the dose profile, dose linearity, and consistency. Here, the authors report the performance of the Artiste™ accelerator (Siemens, Erlangen, Germany) in delivering low-MU FFF beams. A 6 MV flattened beam (6X) with 300 MU/min dose rate and FFF beams of 7 (7XU) and 11 MV (11XU), each with a 500 MU/min dose rate, were measured at 1, 2, 3, 5, 8, 10, and 20 MU settings. For the 2000 MU/min dose rate, the 7 (7XUH) and 11 MV (11XUH) beams were set at 10, 15, 20, 25, and 30 MU because of the limits of the minimum MU settings. Beams with 20 × 20 and 10 × 10 cm(2) field sizes were alternately measured ten times in intensity modulated (IM) mode, with which Siemens linacs regulate beam delivery for step-and-shoot IMRT. The in- and crossplane beam profiles were measured using a Profiler™ Model 1170 (Sun Nuclear Corporation, Melbourne, FL) in multiframe mode. The frames of 20 × 20 cm(2) beams were identified at the off-axis profile. The 6X beam profile was normalized at the central axis. The 7 and 11 MV FFF beam profiles were rescaled to set the dose at the central axis at 145% and 170%, respectively. Point doses were also measured using a Farmer-type ionization chamber and water-equivalent solid phantom to evaluate the linearity and consistency of low-MU beam delivery. The values displayed on the electrometer were recognized with a USB-type camera and read with open-source optical character recognition software. The symmetry measurements of the 6X, 7XU, and 11XU beam profiles were better than 2% for beams ≥ 2 MU and improved with increasing MU. The variations in flatness of FFF beams ≥ 2 MU were ± 5%. The standard deviation of the symmetry and flatness also decreased with increasing MU. The linearity of the 6X beam was ± 1% and ± 2% for the beams of ≥ 5 and ≥ 3 MU, respectively. The 7XU and 11XU beams of ≥ 2 MU showed linearity with ± 2% except the 7XU beam of 8 MU (+2.9%). The profiles of the FFF beams with 2000 and 500 MU/min dose rate were similar. The characteristics of low-MU beams delivered in IM mode were evaluated using an automatic measurement system developed in this study. The authors demonstrated that the profiles of FFF beams of the Artiste™ linac were highly stable, even at low MU. The linearity of dose output was also stable for beams ≥ 2 MU.

  15. Small Field-of-view single-shot EPI-DWI of the prostate: Evaluation of spatially-tailored two-dimensional radiofrequency excitation pulses.

    PubMed

    Attenberger, Ulrike I; Rathmann, Nils; Sertdemir, Metin; Riffel, Philipp; Weidner, Anja; Kannengiesser, Stefan; Morelli, John N; Schoenberg, Stefan O; Hausmann, Daniel

    2016-06-01

    Spatially-tailored (RF) excitation pulses in echo-planar imaging (EPI), combined with a decreased FOV in the phase-encoding direction, enable a reduction of k-space acquisition lines, which shortens the echo train length (ETL) and reduces susceptibility artifacts. The purpose of this study was to evaluate the image quality of a zoomed EPI (z-EPI) sequence in diffusion-weighted imaging (DWI) of the prostate in comparison to a conventional single-shot EPI using single-channel (c-EPI1) and multi-channel (c-EPI2) RF excitation, with and without use of an endorectal coil. 33 consecutive patients (mean age: 61 +/- 9 years; mean PSA: 8.67±6.23 ng/ml) with examinations between 10/2012 and 02/2014 were analyzed in this retrospective study. In 26 of 33 patients the initial multiparametric (mp)-MRI was performed on a whole-body 3T scanner (Magnetom Trio, Siemens, Erlangen, Germany) using an endorectal coil (c (conventional)-EPI1). Zoomed-EPI (Z-EPI) examinations of these patients and a complete mp-MRI protocol including c-EPI2 of 7 additional patients were carried out on another 3T wb MR scanner with two-channel dynamic parallel transmit capability (Magnetom Skyra with TimTX TrueShape, Siemens). For z-EPI, the one-dimensional spatially selective RF excitation pulse was replaced by a two-dimensional RF pulse. Degree of image blur and susceptibility artifacts (0=not present to 3= non-diagnostic), maximum image distortion (mm), apparent diffusion coefficient (ADC) values, as well as overall scan preference were evaluated. SNR maps were generated to compare c-EPI2 and z-EPI. Overall image quality of z-EPI was preferred by both readers in all examinations with a single exception. Susceptibility artifacts were rated significantly lower on z-EPI compared to both other methods (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01) as well as image blur (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01). Image distortion was not statistically significantly reduced with z-EPI (z-EPI vs c-EPI1: p=0.12; z-EPI vs c-EPI2: p=0.42). Interobserver agreement for ratings of susceptibility artifacts, image blur and overall scan preference was good. SNR was higher for z-EPI than for c-EPI1 (n=1). Z-EPI leads to significant improvements in image quality and artifacts as well as image blur reduction improving prostate DWI and enabling accurate fusion with conventional sequences. The improved fusion could lead to advantages in the field of MRI-guided biopsy suspicous lesions and performance of locally ablative procedures for prostate cancer. Copyright © 2015. Published by Elsevier GmbH.

  16. Advanced steam power plant concepts with optimized life-cycle costs: A new approach for maximum customer benefit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seiter, C.

    1998-07-01

    The use of coal power generation applications is currently enjoying a renaissance. New highly efficient and cost-effective plant concepts together with environmental protection technologies are the main factors in this development. In addition, coal is available on the world market at attractive prices and in many places it is more readily available than gas. At the economical leading edge, standard power plant concepts have been developed to meet the requirements of emerging power markets. These concepts incorporate the high technological state-of-the-art and are designed to achieve lowest life-cycle costs. Low capital cost, fuel costs and operating costs in combination withmore » shortest lead times are the main assets that make these plants attractive especially for IPPs and Developers. Other aspects of these comprehensive concepts include turnkey construction and the willingness to participate in BOO/BOT projects. One of the various examples of such a concept, the 2 x 610-MW Paiton Private Power Project Phase II in Indonesia, is described in this paper. At the technological leading edge, Siemens has always made a major contribution and was pacemaker for new developments in steam power plant technology. Modern coal-fired steam power plants use computer-optimized process and plant design as well as advanced materials, and achieve efficiencies exceeding 45%. One excellent example of this high technology is the world's largest lignite-fired steam power plant Schwarze Pumpe in Germany, which is equipped with two 800 MW Siemens steam turbine generators with supercritical steam parameters. The world's largest 50-Hz single-shaft turbine generator with supercritical steam parameters rated at 1025 MW for the Niederaussem lignite-fired steam power plant in Germany is a further example of the sophisticated Siemens steam turbine technology and sets a new benchmark in this field.« less

  17. The effect of helium on ventilator performance: study of five ventilators and a bedside Pitot tube spirometer.

    PubMed

    Oppenheim-Eden, A; Cohen, Y; Weissman, C; Pizov, R

    2001-08-01

    To assess in vitro the performance of five mechanical ventilators-Siemens 300 and 900C (Siemens-Elma; Solna, Sweden), Puritan Bennett 7200 (Nellcor Puritan Bennett; Pleasanton, CA), Evita 4 (Dragerwerk; Lubeck, Germany), and Bear 1000 (Bear Medical Systems; Riverside CA)-and a bedside sidestream spirometer (Datex CS3 Respiratory Module; Datex-Ohmeda; Helsinki, Finland) during ventilation with helium-oxygen mixtures. In vitro study. ICUs of two university-affiliated hospitals. Each ventilator was connected to 100% helium through compressed air inlets and then tested at three to six different tidal volume (VT) settings using various helium-oxygen concentrations (fraction of inspired oxygen [FIO(2)] of 0.2 to 1.0). FIO(2) and VT were measured with the Datex CS3 spirometer, and VT was validated with a water-displacement spirometer. The Puritan Bennett 7200 ventilator did not function with helium. With the other four ventilators, delivered FIO(2) was lower than the set FIO(2). For the Siemens 300 and 900C ventilators, this difference could be explained by the lack of 21% oxygen when helium was connected to the air supply port, while for the other two ventilators, a nonlinear relation was found. The VT of the Siemens 300 ventilator was independent of helium concentration, while for the other three ventilators, delivered VT was greater than the set VT and was dependent on helium concentration. During ventilation with 80% helium and 20% oxygen, VT increased to 125% of set VT for the Siemens 900C ventilator, and more than doubled for the Evita 4 and Bear 1000 ventilators. Under the same conditions, the Datex CS3 spirometer underestimated the delivered VT by about 33%. At present, no mechanical ventilator is calibrated for use with helium. This investigation offers correction factors for four ventilators for ventilation with helium.

  18. Malignant melanoma of the skin: long-term follow-up and time to first recurrence.

    PubMed

    Hohnheiser, Annika M; Gefeller, Olaf; Göhl, Jonas; Schuler, Gerold; Hohenberger, Werner; Merkel, Susanne

    2011-03-01

    Surgical excision can cure most patients with malignant melanoma of the skin. However, the risk of recurrence remains for years. The aim of our study was to identify factors that influence time to recurrence and survival after the first recurrence with a special interest in late recurrences. Data from 2487 patients with malignant melanoma and primary treatment between 1978 and 1997 at the Department of Surgery or the Department of Dermatology, University Hospital Erlangen, Germany, were prospectively collected in the Melanoma Registry of the University Hospital Erlangen. After a median follow-up period of 13 years, overall survival, the time to first recurrence and survival after the first relapse were examined in univariate and multivariate analyses. Overall survival was found to be significantly worse in older patients, men, melanoma of the head or trunk, and melanoma with high pT and pN categories. In 523 patients, relapse from malignant melanoma was observed after a median of 24 months. Among patients with recurrences, young age and low pT and pN categories proved to be independent factors that prolonged the disease-free interval. Advanced age at the time of the recurrence diagnosis, male sex, high pN category, and distant metastases as the first manifestation of recurrence were associated with a poor prognosis after the first recurrence. Although thin lesions have a favorable prognosis, among a cohort with recurrences they showed a relatively high rate of late recurrences. These late recurrences have an extremely poor prognosis when they present with distant metastases.

  19. Measurements and calculations of water velocity, momentum flux, and related flow parameters obtaned from single-phase water integral acceptance tests of the PKL instrumented spool pieces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stein, W.

    The operation of the emergency core cooling system and its related steam-binding problems in pressurized water reactors is the subject of a cooperative study by the United States, Germany, and Japan. Lawrence Livermore Laboratory and EG and G, Inc., San Ramon Operations, are responsible for the design, hardware, and software of the 80.8-mm and 113-mm spool piece measurement systems for the German Primarkreislauf (PKL) Test Facility at Kraftwerk Union in Erlangen, West Germany. This work was done for the US Nuclear Regulatory Commission, Division of Reactor Safety Research, under its 3-D Technical Support and Instrumentation Program. Four instrumented spools capablemore » of measuring individual phase parameters in two-phase flows were constructed. Each spool contains a flow turbine, drag screen, three-beam densitometer, and pressure and temperature probes. A computerized data acquisition system is also provided to store and analyze data from the four spools. The four spools were shipped to the PKL Test Facility in West Germany for acceptance testing in a water-flow loop. Spool measurements of velocity and momentum flux were compared to the values obtained from an orifice meter installed in the loop piping system. The turbine flowmeter velocity data for all tests were within allowable tolerances. Drag screen momentum flux measurements were also within tolerance with the exception of a few points.« less

  20. Feasibility and validation of virtual autopsy for dental identification using the Interpol dental codes.

    PubMed

    Franco, Ademir; Thevissen, Patrick; Coudyzer, Walter; Develter, Wim; Van de Voorde, Wim; Oyen, Raymond; Vandermeulen, Dirk; Jacobs, Reinhilde; Willems, Guy

    2013-05-01

    Virtual autopsy is a medical imaging technique, using full body computed tomography (CT), allowing for a noninvasive and permanent observation of all body parts. For dental identification clinically and radiologically observed ante-mortem (AM) and post-mortem (PM) oral identifiers are compared. The study aimed to verify if a PM dental charting can be performed on virtual reconstructions of full-body CT's using the Interpol dental codes. A sample of 103 PM full-body CT's was collected from the forensic autopsy files of the Department of Forensic Medicine University Hospitals, KU Leuven, Belgium. For validation purposes, 3 of these bodies underwent a complete dental autopsy, a dental radiological and a full-body CT examination. The bodies were scanned in a Siemens Definition Flash CT Scanner (Siemens Medical Solutions, Germany). The images were examined on 8- and 12-bit screen resolution as three-dimensional (3D) reconstructions and as axial, coronal and sagittal slices. InSpace(®) (Siemens Medical Solutions, Germany) software was used for 3D reconstruction. The dental identifiers were charted on pink PM Interpol forms (F1, F2), using the related dental codes. Optimal dental charting was obtained by combining observations on 3D reconstructions and CT slices. It was not feasible to differentiate between different kinds of dental restoration materials. The 12-bit resolution enabled to collect more detailed evidences, mainly related to positions within a tooth. Oral identifiers, not implemented in the Interpol dental coding were observed. Amongst these, the observed (3D) morphological features of dental and maxillofacial structures are important identifiers. The latter can become particularly more relevant towards the future, not only because of the inherent spatial features, yet also because of the increasing preventive dental treatment, and the decreasing application of dental restorations. In conclusion, PM full-body CT examinations need to be implemented in the PM dental charting protocols and the Interpol dental codes should be adapted accordingly. Copyright © 2012 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  1. Contrast-enhanced magnetic resonance angiography: first-pass arterial enhancement as a function of gadolinium-chelate concentration, and the saline chaser volume and injection rate.

    PubMed

    Husarik, Daniela B; Bashir, Mustafa R; Weber, Paul W; Nichols, Eli B; Howle, Laurens E; Merkle, Elmar M; Nelson, Rendon C

    2012-02-01

    To evaluate the effect of the contrast medium (CM) concentration and the saline chaser volume and injection rate on first-pass aortic enhancement characteristics in contrast-enhanced magnetic resonance angiography using a physiologic flow phantom. Imaging was performed on a 3.0-T magnetic resonance system (MAGNETOM Trio, Siemens Healthcare Solutions, Inc, Erlangen, Germany) using a 2-dimensional fast low angle shot T1-weighted sequence (repetition time, 500 milliseconds; echo time, 1.23 milliseconds; flip angle, 8 degrees; 1 frame/s × 60 seconds). The following CM concentrations injected at 2 mL/s were used with 3 different contrast agents (gadolinium [Gd]-BOPTA, Gd-HP-DO3A, Gd-DTPA): 20 mL of undiluted CM (100%) and 80%, 40%, 20%, 10%, 5%, and 2.5% of the full amount, all diluted in saline to a volume of 20 mL to ensure equal bolus volume. The CM was followed by saline chasers of 20 to 60 mL injected at 2 mL/s and 6 mL/s. Aortic signal intensity (SI) was measured, and normalized SI versus time (SI/Tn) curves were generated. The maximal SI (SI(max)), bolus length, and areas under the SI/Tn curve were calculated. Decreasing the CM concentration from 100% to 40% resulted in a decrease of SI(max) to 86.1% (mean). Further decreasing the CM concentration to 2.5% decreased SI(max) to 5.1% (mean). Altering the saline chaser volume had no significant effect on SI(max). Increasing the saline chaser injection rate had little effect (mean increase, 2.2%) on SI(max) when using ≥40% of CM. There was a larger effect (mean increase, 19.6%) when ≤20% of CM were used. Bolus time length was significantly shorter (P < 0.001), and area under the SI/T(n) curve was significantly smaller (P < 0.01) for the CM protocols followed by a saline chaser injected at 6 mL/s compared with a saline chaser injected at 2 mL/s. With 40% of CM and a fast saline chaser, SImax close to that with undiluted CM can be achieved. An increased saline chaser injection rate has a more pronounced effect on aortic enhancement characteristics at lower CM concentrations than at higher CM concentrations.

  2. High Spatial Resolution Cardiovascular Magnetic Resonance at 7.0 Tesla in Patients with Hypertrophic Cardiomyopathy - First Experiences: Lesson Learned from 7.0 Tesla.

    PubMed

    Prothmann, Marcel; von Knobelsdorff-Brenkenhoff, Florian; Töpper, Agnieszka; Dieringer, Matthias A; Shahid, Etham; Graessl, Andreas; Rieger, Jan; Lysiak, Darius; Thalhammer, C; Huelnhagen, Till; Kellman, Peter; Niendorf, Thoralf; Schulz-Menger, Jeanette

    2016-01-01

    Cardiovascular Magnetic Resonance (CMR) provides valuable information in patients with hypertrophic cardiomyopathy (HCM) based on myocardial tissue differentiation and the detection of small morphological details. CMR at 7.0T improves spatial resolution versus today's clinical protocols. This capability is as yet untapped in HCM patients. We aimed to examine the feasibility of CMR at 7.0T in HCM patients and to demonstrate its capability for the visualization of subtle morphological details. We screened 131 patients with HCM. 13 patients (9 males, 56 ±31 years) and 13 healthy age- and gender-matched subjects (9 males, 55 ±31years) underwent CMR at 7.0T and 3.0T (Siemens, Erlangen, Germany). For the assessment of cardiac function and morphology, 2D CINE imaging was performed (voxel size at 7.0T: (1.4x1.4x2.5) mm3 and (1.4x1.4x4.0) mm3; at 3.0T: (1.8x1.8x6.0) mm3). Late gadolinium enhancement (LGE) was performed at 3.0T for detection of fibrosis. All scans were successful and evaluable. At 3.0T, quantification of the left ventricle (LV) showed similar results in short axis view vs. the biplane approach (LVEDV, LVESV, LVMASS, LVEF) (p = 0.286; p = 0.534; p = 0.155; p = 0.131). The LV-parameters obtained at 7.0T where in accordance with the 3.0T data (pLVEDV = 0.110; pLVESV = 0.091; pLVMASS = 0.131; pLVEF = 0.182). LGE was detectable in 12/13 (92%) of the HCM patients. High spatial resolution CINE imaging at 7.0T revealed hyperintense regions, identifying myocardial crypts in 7/13 (54%) of the HCM patients. All crypts were located in the LGE-positive regions. The crypts were not detectable at 3.0T using a clinical protocol. CMR at 7.0T is feasible in patients with HCM. High spatial resolution gradient echo 2D CINE imaging at 7.0T allowed the detection of subtle morphological details in regions of extended hypertrophy and LGE.

  3. Intraoperative magnetic resonance imaging with the magnetom open scanner: concepts, neurosurgical indications, and procedures: a preliminary report.

    PubMed

    Steinmeier, R; Fahlbusch, R; Ganslandt, O; Nimsky, C; Buchfelder, M; Kaus, M; Heigl, T; Lenz, G; Kuth, R; Huk, W

    1998-10-01

    Intraoperative magnetic resonance imaging (MRI) is now available with the General Electric MRI system for dedicated intraoperative use. Alternatively, non-dedicated MRI systems require fewer specific adaptations of instrumentation and surgical techniques. In this report, clinical experiences with such a system are presented. All patients were surgically treated in a "twin operating theater," consisting of a conventional operating theater with complete neuronavigation equipment (StealthStation and MKM), which allowed surgery with magnetically incompatible instruments, conventional instrumentation and operating microscope, and a radiofrequency-shielded operating room designed for use with an intraoperative MRI scanner (Magnetom Open; Siemens AG, Erlangen, Germany). The Magnetom Open is a 0.2-T MRI scanner with a resistive magnet and specific adaptations that are necessary to integrate the scanner into the surgical environment. The operating theaters lie close together, and patients can be intraoperatively transported from one room to the other. This retrospective analysis includes 55 patients with cerebral lesions, all of whom were surgically treated between March 1996 and September 1997. Thirty-one patients with supratentorial tumors were surgically treated (with navigational guidance) in the conventional operating room, with intraoperative MRI for resection control. For 5 of these 31 patients, intraoperative resection control revealed significant tumor remnants, which led to further tumor resection guided by the information provided by intraoperative MRI. Intraoperative MRI resection control was performed in 18 transsphenoidal operations. In cases with suspected tumor remnants, the surgeon reexplored the sellar region; additional tumor tissue was removed in three of five cases. Follow-up scans were obtained for all patients 1 week and 2 to 3 months after surgery. For 14 of the 18 patients, the images obtained intraoperatively were comparable to those obtained after 2 to 3 months. Intraoperative MRI was also used for six patients undergoing temporal lobe resections for treatment of pharmacoresistant seizures. For these patients, the extent of neocortical and mesial resection was tailored to fit the preoperative findings of morphological and electrophysiological alterations, as well as intraoperative electrocorticographic findings. Intraoperative MRI with the Magnetom Open provides considerable additional information to optimize resection during surgical treatment of supratentorial tumors, pituitary adenomas, and epilepsy. The twin operating theater is a true alternative to a dedicated MRI system. Additional efforts are necessary to improve patient transportation time and instrument guidance within the scanner.

  4. Quantitative comparison of noise texture across CT scanners from different manufacturers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solomon, Justin B.; Christianson, Olav; Samei, Ehsan

    2012-10-15

    Purpose: To quantitatively compare noise texture across computed tomography (CT) scanners from different manufacturers using the noise power spectrum (NPS). Methods: The American College of Radiology CT accreditation phantom (Gammex 464, Gammex, Inc., Middleton, WI) was imaged on two scanners: Discovery CT 750HD (GE Healthcare, Waukesha, WI), and SOMATOM Definition Flash (Siemens Healthcare, Germany), using a consistent acquisition protocol (120 kVp, 0.625/0.6 mm slice thickness, 250 mAs, and 22 cm field of view). Images were reconstructed using filtered backprojection and a wide selection of reconstruction kernels. For each image set, the 2D NPS were estimated from the uniform section ofmore » the phantom. The 2D spectra were normalized by their integral value, radially averaged, and filtered by the human visual response function. A systematic kernel-by-kernel comparison across manufacturers was performed by computing the root mean square difference (RMSD) and the peak frequency difference (PFD) between the NPS from different kernels. GE and Siemens kernels were compared and kernel pairs that minimized the RMSD and |PFD| were identified. Results: The RMSD (|PFD|) values between the NPS of GE and Siemens kernels varied from 0.01 mm{sup 2} (0.002 mm{sup -1}) to 0.29 mm{sup 2} (0.74 mm{sup -1}). The GE kernels 'Soft,''Standard,''Chest,' and 'Lung' closely matched the Siemens kernels 'B35f,''B43f,''B41f,' and 'B80f' (RMSD < 0.05 mm{sup 2}, |PFD| < 0.02 mm{sup -1}, respectively). The GE 'Bone,''Bone+,' and 'Edge' kernels all matched most closely with Siemens 'B75f' kernel but with sizeable RMSD and |PFD| values up to 0.18 mm{sup 2} and 0.41 mm{sup -1}, respectively. These sizeable RMSD and |PFD| values corresponded to visually perceivable differences in the noise texture of the images. Conclusions: It is possible to use the NPS to quantitatively compare noise texture across CT systems. The degree to which similar texture across scanners could be achieved varies and is limited by the kernels available on each scanner.« less

  5. Quantitative comparison of noise texture across CT scanners from different manufacturers.

    PubMed

    Solomon, Justin B; Christianson, Olav; Samei, Ehsan

    2012-10-01

    To quantitatively compare noise texture across computed tomography (CT) scanners from different manufacturers using the noise power spectrum (NPS). The American College of Radiology CT accreditation phantom (Gammex 464, Gammex, Inc., Middleton, WI) was imaged on two scanners: Discovery CT 750HD (GE Healthcare, Waukesha, WI), and SOMATOM Definition Flash (Siemens Healthcare, Germany), using a consistent acquisition protocol (120 kVp, 0.625∕0.6 mm slice thickness, 250 mAs, and 22 cm field of view). Images were reconstructed using filtered backprojection and a wide selection of reconstruction kernels. For each image set, the 2D NPS were estimated from the uniform section of the phantom. The 2D spectra were normalized by their integral value, radially averaged, and filtered by the human visual response function. A systematic kernel-by-kernel comparison across manufacturers was performed by computing the root mean square difference (RMSD) and the peak frequency difference (PFD) between the NPS from different kernels. GE and Siemens kernels were compared and kernel pairs that minimized the RMSD and |PFD| were identified. The RMSD (|PFD|) values between the NPS of GE and Siemens kernels varied from 0.01 mm(2) (0.002 mm(-1)) to 0.29 mm(2) (0.74 mm(-1)). The GE kernels "Soft," "Standard," "Chest," and "Lung" closely matched the Siemens kernels "B35f," "B43f," "B41f," and "B80f" (RMSD < 0.05 mm(2), |PFD| < 0.02 mm(-1), respectively). The GE "Bone," "Bone+," and "Edge" kernels all matched most closely with Siemens "B75f" kernel but with sizeable RMSD and |PFD| values up to 0.18 mm(2) and 0.41 mm(-1), respectively. These sizeable RMSD and |PFD| values corresponded to visually perceivable differences in the noise texture of the images. It is possible to use the NPS to quantitatively compare noise texture across CT systems. The degree to which similar texture across scanners could be achieved varies and is limited by the kernels available on each scanner.

  6. Comparison of the Corneal Power Measurements with the TMS4-Topographer, Pentacam HR, IOL Master, and Javal Keratometer.

    PubMed

    Dehnavi, Zahra; Khabazkhoob, Mehdi; Mirzajani, Ali; Jabbarvand, Mahmood; Yekta, Abbasali; Jafarzadehpur, Ebrahim

    2015-01-01

    The aim was to compare the corneal curvature and power measured with a corneal topographer, Scheimpflug camera, optical biometer, and Javal keratometer. A total of 76 myopic individuals who were candidates for photorefractive keratectomy were selected in a cross-sectional study. Manual keratometry (Javal Schiotz type; Haag-Streit AG, Koeniz, Switzerland), automated keratometry (IOL Master version 3.02, Carl Zeiss Meditec, Jena, Germany), topography (TMS4, Tomey, Erlangen, Germany), and Pentacam HR (Oculus, Wetzlar, Germany) were performed for all participants. The 95% limits of agreement (LOAs) were reported to evaluate the agreement between devices. The mean corneal power measurements were 44.3 ± 1.59, 44.25 ± 1.59, 43.68 ± 1.44, and 44.31 ± 1.61 D with a Javal keratometer, TMS4-topographer, the Pentacam and IOL Master respectively. Only the IOL Master showed no significant difference with Javal keratometer in measuring the corneal power (P = 0.965). The correlations of the Javal keratometer with TMS4-topography, Pentacam, and IOL Master was 0.991. 0.982, and 0.993 respectively. The 95% LOAs of the Javal keratometer with TMS4-topography, Pentacam, and IOL Master were - 0.361 to 0.49, -0.01 to 1.14, and - 0.36 to 0.36 D, respectively. Although the correlation of Pentacam, TMS4-topography, IOL Master, and Javal keratometer in measuring keratometry was high, only the IOL Master showed no significant difference with the Javal keratometer. The IOL Master had the best agreement with Javal keratometry.

  7. Chronotype differences in cortical thickness: grey matter reflects when you go to bed.

    PubMed

    Rosenberg, Jessica; Jacobs, Heidi I L; Maximov, Ivan I; Reske, Martina; Shah, N J

    2018-06-15

    Based on individual circadian cycles and associated cognitive rhythms, humans can be classified via standardised self-reports as being early (EC), late (LC) and intermediate (IC) chronotypes. Alterations in neural cortical structure underlying these chronotype differences have rarely been investigated and are the scope of this study. 16 healthy male ECs, 16 ICs and 16 LCs were measured with a 3 T MAGNETOM TIM TRIO (Siemens, Erlangen) scanner using a magnetization prepared rapid gradient echo sequence. Data were analysed by applying voxel-based morphometry (VBM) and vertex-wise cortical thickness (CTh) analysis. VBM analysis revealed that ECs showed significantly lower grey matter volumes bilateral in the lateral occipital cortex and the precuneus as compared to LCs, and in the right lingual gyrus, occipital fusiform gyrus and the occipital pole as compared to ICs. CTh findings showed lower grey matter volumes for ECs in the left anterior insula, precuneus, inferior parietal cortex, and right pars triangularis than for LCs, and in the right superior parietal gyrus than for ICs. These findings reveal that chronotype differences are associated with specific neural substrates of cortical thickness, surface areas, and folding. We conclude that this might be the basis for chronotype differences in behaviour and brain function. Furthermore, our results speak for the necessity of considering "chronotype" as a potentially modulating factor in all kinds of structural brain-imaging experiments.

  8. Technical Note: Development and validation of an open data format for CT projection data.

    PubMed

    Chen, Baiyu; Duan, Xinhui; Yu, Zhicong; Leng, Shuai; Yu, Lifeng; McCollough, Cynthia

    2015-12-01

    Lack of access to projection data from patient CT scans is a major limitation for development and validation of new reconstruction algorithms. To meet this critical need, this work developed and validated a vendor-neutral format for CT projection data, which will further be employed to build a library of patient projection data for public access. A digital imaging and communication in medicine (DICOM)-like format was created for CT projection data (CT-PD), named the DICOM-CT-PD format. The format stores attenuation information in the DICOM image data block and stores parameters necessary for reconstruction in the DICOM header under various tags (51 tags to store the geometry and scan parameters and 9 tags to store patient information). To validate the accuracy and completeness of the new format, CT projection data from helical scans of the ACR CT accreditation phantom were acquired from two clinical CT scanners (Somatom Definition Flash, Siemens Healthcare, Forchheim, Germany and Discovery CT750 HD, GE Healthcare, Waukesha, WI). After decoding (by the authors for Siemens, by the manufacturer for GE), the projection data were converted to the DICOM-CT-PD format. Off-line CT reconstructions were performed by internal and external reconstruction researchers using only the information stored in the DICOM-CT-PD files and the DICOM-CT-PD field definitions. Compared with the commercially reconstructed CT images, the off-line reconstructed images created using the DICOM-CT-PD format are similar in terms of CT numbers (differences of 5 HU for the bone insert and -9 HU for the air insert), image noise (±1 HU), and low contrast detectability (6 mm rods visible in both). Because of different reconstruction approaches, slightly different in-plane and cross-plane high contrast spatial resolution were obtained compared to those reconstructed on the scanners (axial plane: GE off-line, 7 lp/cm; GE commercial, 7 lp/cm; Siemens off-line, 8 lp/cm; Siemens commercial, 7 lp/cm. Coronal plane: Siemens off-line, 6 lp/cm; Siemens commercial, 8 lp/cm). A vendor-neutral extended DICOM format has been developed that enables open sharing of CT projection data from third-generation CT scanners. Validation of the format showed that the geometric parameters and attenuation information in the DICOM-CT-PD file were correctly stored, could be retrieved with use of the provided instructions, and contained sufficient data for reconstruction of CT images that approximated those from the commercial scanner.

  9. [The professional and private situation of male and female physicians entering postgraduate medical education in Germany].

    PubMed

    van den Bussche, H; Wonneberger, C; Birck, S; Schultz, J-H; Robra, B-P; Schmidt, A; Stosch, C; Wagner, R; Scherer, M; Pöge, K; Rothe, K; Gedrose, B

    2014-02-01

    This study investigated the professional and the private situation of medical interns at the onset of their postgraduate training in Germany. We analysed the contractual situation and the working hours in the hospital, the professional situation of the partner and the number of hours invested in private life with special reference to gender and children. A standardised postal survey was conducted among all last year medical students in the medical faculties of Erlangen, Giessen, Hamburg, Heidelberg, Cologne, Leipzig and Magdeburg after entering postgraduate training. 1 009 were contacted for a first follow-up one year later and 87% responded. Descriptive statistics and regression analysis were performed. The analysis shows that female physicians are disadvantaged compared to males with regard to various professional and private conditions relevant for career development, especially when children are present. We found a large number of hints pointing towards a persistence of traditional role patterns within the couple relationship. These conditions differed substantially between the regions of former German Federal and former German Democratic Republic. A growing number of children in the study population in the course of the longitudinal analysis will show if these gender-related differences persist in the course of the training period and which influences on career development can be observed. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Development of an integrated, unattended assay system for LWR-MOX fuel pellet trays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, J.E.; Hatcher, C.R.; Pollat, L.L.

    1994-08-01

    Four identical unattended plutonium assay systems have been developed for use at the new light-water-reactor mixed oxide (LWR-MOX) fuel fabrication facility at Hanau, Germany. The systems provide quantitative plutonium verification for all MOX pellet trays entering or leaving a large, intermediate store. Pellet-tray transport and storage systems are highly automated. Data from the ``I-Point`` (information point) assay systems will be shared by the Euratom and International Atomic Energy Agency (IAEA) Inspectorates. The I-Point system integrates, for the first time, passive neutron coincidence counting (NCC) with electro-mechanical sensing (EMS) in unattended mode. Also, provisions have been made for adding high-resolution gammamore » spectroscopy. The system accumulates data for every tray entering or leaving the store between inspector visits. During an inspection, data are analyzed and compared with operator declarations for the previous inspection period, nominally one month. Specification of the I-point system resulted from a collaboration between the IAEA, Euratom, Siemens, and Los Alamos. Hardware was developed by Siemens and Los Alamos through a bilateral agreement between the German Federal Ministry of Research and Technology (BMFT) and the US DOE. Siemens also provided the EMS subsystem, including software. Through the USSupport Program to the IAEA, Los Alamos developed the NCC software (NCC COLLECT) and also the software for merging and reviewing the EMS and NCC data (MERGE/REVIEW). This paper describes the overall I-Point system, but emphasizes the NCC subsystem, along with the NCC COLLECT and MERGE/REVIEW codes. We also summarize comprehensive testing results that define the quality of assay performance.« less

  11. Polarized Negative Light Ions at the Cooler Synchrotron COSY/Juelich

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gebel, R.; Felden, O.; Rossen, P. von

    2005-04-06

    The polarized ion source at the cooler synchrotron facility COSY of the research centre Juelich in Germany delivers negative polarized protons or deuterons for medium energy experiments. The polarized ion source, originally built by the universities of Bonn, Erlangen and Cologne, is based on the colliding beams principle, using after an upgrade procedure an intense pulsed neutralized caesium beam for charge exchange with a pulsed highly polarized hydrogen beam. The source is operated at 0.5 Hz repetition rate with 20 ms pulse length, which is the maximum useful length for the injection into the synchrotron. Routinely intensities of 20 {mu}Amore » are delivered for injection into the cyclotron of the COSY facility. For internal targets the intensity of 2 mA and a polarization up to 90% have been reached. Reliable long-term operation for experiments at COSY for up to 9 weeks has been achieved. Since 2003 polarized deuterons with different combinations of vector and tensor polarization were delivered to experiments.« less

  12. [The internet as an information source for family caregivers of dementia patients].

    PubMed

    Grässel, Elmar; Bleich, Stefan; Meyer-Wegener, Klaus; Schmid, Ute; Kornhuber, Johannes; Prokosch, Hans-Ulrich

    2009-04-01

    What significance has the Internet as a source of information for family caregivers of dementia patients? In Middle Franconia (Germany), 391 family caregivers were requested to participate in a questionnaire-based postal survey about the significance of the Internet and other sources of information on dementia. The family caregivers in question were the relatives of patients of the Memory Clinic at Erlangen University Psychiatric Hospital, members of the Alzheimer's Society of Middle Franconia or the Nuremberg Family Counselling Society. Younger and better-educated family caregivers more often own a computer with Internet access than older ones. The Internet is in 4th place on their list of sources of information. Although doctors are by far the most important source, counselling centres and literature are rated only just before the Internet. The Internet is particularly significant for the younger better-educated family caregivers, independent of gender, as a source of information on the diagnosis and treatment of dementia.

  13. Robotic digital subtraction angiography systems within the hybrid operating room.

    PubMed

    Murayama, Yuichi; Irie, Koreaki; Saguchi, Takayuki; Ishibashi, Toshihiro; Ebara, Masaki; Nagashima, Hiroyasu; Isoshima, Akira; Arakawa, Hideki; Takao, Hiroyuki; Ohashi, Hiroki; Joki, Tatsuhiro; Kato, Masataka; Tani, Satoshi; Ikeuchi, Satoshi; Abe, Toshiaki

    2011-05-01

    Fully equipped high-end digital subtraction angiography (DSA) within the operating room (OR) environment has emerged as a new trend in the fields of neurosurgery and vascular surgery. To describe initial clinical experience with a robotic DSA system in the hybrid OR. A newly designed robotic DSA system (Artis zeego; Siemens AG, Forchheim, Germany) was installed in the hybrid OR. The system consists of a multiaxis robotic C arm and surgical OR table. In addition to conventional neuroendovascular procedures, the system was used as an intraoperative imaging tool for various neurosurgical procedures such as aneurysm clipping and spine instrumentation. Five hundred one neurosurgical procedures were successfully conducted in the hybrid OR with the robotic DSA. During surgical procedures such as aneurysm clipping and arteriovenous fistula treatment, intraoperative 2-/3-dimensional angiography and C-arm-based computed tomographic images (DynaCT) were easily performed without moving the OR table. Newly developed virtual navigation software (syngo iGuide; Siemens AG) can be used in frameless navigation and in access to deep-seated intracranial lesions or needle placement. This newly developed robotic DSA system provides safe and precise treatment in the fields of endovascular treatment and neurosurgery.

  14. Corneal tissue interactions of a new 345 nm ultraviolet femtosecond laser.

    PubMed

    Hammer, Christian M; Petsch, Corinna; Klenke, Jörg; Skerl, Katrin; Paulsen, Friedrich; Kruse, Friedrich E; Seiler, Theo; Menzel-Severing, Johannes

    2015-06-01

    To assess the suitability of a new 345 nm ultraviolet (UV) femtosecond laser for refractive surgery. Department of Ophthalmology, University of Erlangen-Nürnberg, Erlangen, Germany. Experimental study. Twenty-five porcine corneas were used for stromal flap or lamellar bed creation (stromal depth, 150 μm) and 15 rabbit corneas for lamellar bed creation near the endothelium. Ultraviolet femtosecond laser cutting-line morphology, gas formation, and keratocyte death rate were evaluated using light and electron microscopy and compared with a standard infrared (IR) femtosecond laser. Endothelial cell survival was examined after application of a laser cut near the endothelium. Flaps created by the UV laser were lifted easily. Gas formation was reduced 4.2-fold compared with the IR laser (P = .001). The keratocyte death rate near the interface was almost doubled; however, the death zone was confined to a region within 38 μm ± 10 (SD) along the cutting line. Histologically and ultrastructurally, a distinct and continuous cutting line was not found after UV femtosecond laser application if flap lifting was omitted and standard energy parameters were used. Instead, a regular pattern of vertical striations, presumably representing self-focusing induced regions of optical tissue breakdown, were identified. Lamellar bed creation with standard energy parameters 50 μm from the endothelium rendered the endothelial cells intact and viable. The new 345 nm femtosecond laser is a candidate for pending in vivo trials and future high-precision flap creation, intrastromal lenticule extraction, and ultrathin Descemet-stripping endothelial keratoplasty. Mr. Klenke and Ms. Skerl were paid employees of Wavelight GmbH when the study was performed. Dr. Seiler is a scientific consultant to Wavelight GmbH. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  15. A comparison of five standard methods for evaluating image intensity uniformity in partially parallel imaging MRI

    PubMed Central

    Goerner, Frank L.; Duong, Timothy; Stafford, R. Jason; Clarke, Geoffrey D.

    2013-01-01

    Purpose: To investigate the utility of five different standard measurement methods for determining image uniformity for partially parallel imaging (PPI) acquisitions in terms of consistency across a variety of pulse sequences and reconstruction strategies. Methods: Images were produced with a phantom using a 12-channel head matrix coil in a 3T MRI system (TIM TRIO, Siemens Medical Solutions, Erlangen, Germany). Images produced using echo-planar, fast spin echo, gradient echo, and balanced steady state free precession pulse sequences were evaluated. Two different PPI reconstruction methods were investigated, generalized autocalibrating partially parallel acquisition algorithm (GRAPPA) and modified sensitivity-encoding (mSENSE) with acceleration factors (R) of 2, 3, and 4. Additionally images were acquired with conventional, two-dimensional Fourier imaging methods (R = 1). Five measurement methods of uniformity, recommended by the American College of Radiology (ACR) and the National Electrical Manufacturers Association (NEMA) were considered. The methods investigated were (1) an ACR method and a (2) NEMA method for calculating the peak deviation nonuniformity, (3) a modification of a NEMA method used to produce a gray scale uniformity map, (4) determining the normalized absolute average deviation uniformity, and (5) a NEMA method that focused on 17 areas of the image to measure uniformity. Changes in uniformity as a function of reconstruction method at the same R-value were also investigated. Two-way analysis of variance (ANOVA) was used to determine whether R-value or reconstruction method had a greater influence on signal intensity uniformity measurements for partially parallel MRI. Results: Two of the methods studied had consistently negative slopes when signal intensity uniformity was plotted against R-value. The results obtained comparing mSENSE against GRAPPA found no consistent difference between GRAPPA and mSENSE with regard to signal intensity uniformity. The results of the two-way ANOVA analysis suggest that R-value and pulse sequence type produce the largest influences on uniformity and PPI reconstruction method had relatively little effect. Conclusions: Two of the methods of measuring signal intensity uniformity, described by the (NEMA) MRI standards, consistently indicated a decrease in uniformity with an increase in R-value. Other methods investigated did not demonstrate consistent results for evaluating signal uniformity in MR images obtained by partially parallel methods. However, because the spatial distribution of noise affects uniformity, it is recommended that additional uniformity quality metrics be investigated for partially parallel MR images. PMID:23927345

  16. Measurement of myocardial native T1 in cardiovascular diseases and norm in 1291 subjects.

    PubMed

    Liu, Joanna M; Liu, Alexander; Leal, Joana; McMillan, Fiona; Francis, Jane; Greiser, Andreas; Rider, Oliver J; Myerson, Saul; Neubauer, Stefan; Ferreira, Vanessa M; Piechnik, Stefan K

    2017-09-28

    Native T1-mapping provides quantitative myocardial tissue characterization for cardiovascular diseases (CVD), without the need for gadolinium. However, its translation into clinical practice is hindered by differences between techniques and the lack of established reference values. We provide typical myocardial T1-ranges for 18 commonly encountered CVDs using a single T1-mapping technique - Shortened Look-Locker Inversion Recovery (ShMOLLI), also used in the large UK Biobank and Hypertrophic Cardiomyopathy Registry study. We analyzed 1291 subjects who underwent CMR (1.5-Tesla, MAGNETOM-Avanto, Siemens Healthcare, Erlangen, Germany) between 2009 and 2016, who had a single CVD diagnosis, with mid-ventricular T1-map assessment. A region of interest (ROI) was placed on native T1-maps in the "most-affected myocardium", characterized by the presence of late gadolinium enhancement (LGE), or regional wall motion abnormalities (RWMA) on cines. Another ROI was placed in the "reference myocardium" as far as possible from LGE/RWMA, and in the septum if no focal abnormality was present. To further define normality, we included native T1 of healthy subjects from an existing dataset after sub-endocardial pixel-erosions. Native T1 of patients with normal CMR (938 ± 21 ms) was similar compared to healthy subjects (941 ± 23 ms). Across all patient groups (57 ± 19 yrs., 65% males), focally affected myocardium had significantly different T1 value compared to reference myocardium (all p < 0.001). In the affected myocardium, cardiac amyloidosis (1119 ± 61 ms) had the highest native T1 compared to normal and all other CVDs, while iron-overload (795 ± 58 ms) and Anderson-Fabry disease (863 ± 23 ms) had the lowest native reference T1 (all p < 0.001). Future studies designed to detect the large T1 differences between affected and reference myocardium are estimated to require small sample-sizes (n < 50). However, studies designed to detect the small T1 differences between reference myocardium in CVDs and healthy controls can require several thousand of subjects. We provide typical T1-ranges for common clinical cardiac conditions in the largest cohort to-date, using ShMOLLI T1-mapping at 1.5 T. Sample-size calculations from this study may be useful for the design of future studies and trials that use T1-mapping as an endpoint.

  17. A novel segmentation approach for implementation of MRAC in head PET/MRI employing Short-TE MRI and 2-point Dixon method in a fuzzy C-means framework

    NASA Astrophysics Data System (ADS)

    Khateri, Parisa; Rad, Hamidreza Saligheh; Jafari, Amir Homayoun; Ay, Mohammad Reza

    2014-01-01

    Quantitative PET image reconstruction requires an accurate map of attenuation coefficients of the tissue under investigation at 511 keV (μ-map), and in order to correct the emission data for attenuation. The use of MRI-based attenuation correction (MRAC) has recently received lots of attention in the scientific literature. One of the major difficulties facing MRAC has been observed in the areas where bone and air collide, e.g. ethmoidal sinuses in the head area. Bone is intrinsically not detectable by conventional MRI, making it difficult to distinguish air from bone. Therefore, development of more versatile MR sequences to label the bone structure, e.g. ultra-short echo-time (UTE) sequences, certainly plays a significant role in novel methodological developments. However, long acquisition time and complexity of UTE sequences limit its clinical applications. To overcome this problem, we developed a novel combination of Short-TE (ShTE) pulse sequence to detect bone signal with a 2-point Dixon technique for water-fat discrimination, along with a robust image segmentation method based on fuzzy clustering C-means (FCM) to segment the head area into four classes of air, bone, soft tissue and adipose tissue. The imaging protocol was set on a clinical 3 T Tim Trio and also 1.5 T Avanto (Siemens Medical Solution, Erlangen, Germany) employing a triple echo time pulse sequence in the head area. The acquisition parameters were as follows: TE1/TE2/TE3=0.98/4.925/6.155 ms, TR=8 ms, FA=25 on the 3 T system, and TE1/TE2/TE3=1.1/2.38/4.76 ms, TR=16 ms, FA=18 for the 1.5 T system. The second and third echo-times belonged to the Dixon decomposition to distinguish soft and adipose tissues. To quantify accuracy, sensitivity and specificity of the bone segmentation algorithm, resulting classes of MR-based segmented bone were compared with the manual segmented one by our expert neuro-radiologist. Results for both 3 T and 1.5 T systems show that bone segmentation applied in several slices yields average accuracy, sensitivity and specificity higher than 90%. Results indicate that FCM is an appropriate technique for tissue classification in the sinusoidal area where there is air-bone interface. Furthermore, using Dixon method, fat and brain tissues were successfully separated.

  18. [History of homeopathy in Franconia].

    PubMed

    Dross, Fritz; Ruisinger, Marion Maria

    2007-01-01

    The research for this paper was initiated by an Erlangen exhibition project on the history of homeopathy on the occasion of the 250th anniversary of Samuel Hahnemann's birth in 2005. The founder of homeopathic medicine received his doctor of medicine degree at the University of Erlangen in 1779. As Hahnemann spent only four months in Erlangen, homeopathic physicians, patients and apothecaries in the region from Hahnemann's time until today were investigated. The aim was to provide a concise survey of the general problems in the history of homeopathy derived from regional cases which could be illustrated by objects suitable for an exhibition. Thus, the article is not only about the history of homeopathy in Northern Bavaria (Franconia), but also about a shift in the use of media and about doing science the other way round, viz. by starting at the presentation and ending with the sources. The outcome of the project was that most of the crucial topics of the history of homeopathy could be covered on a micro-historic scale: trials, pharmacy, hospital, patients, university, National Socialism.

  19. Organization of the Topical Meeting on Optical Computing Held in Toulon, France on 29 August-2 September 1988

    DTIC Science & Technology

    1988-09-02

    ERIN POMMEL STP..1 6.520 ERLANGEN PFA Docteur BUFOGGRAF KPUPP ATLAS ELEKTR’JN K Grnbt SEEALDS2%JCr-EP 1IEEPSTPR. 235 "ademofiselie CENZ N5’T!TUIT F P...ANOE’?YA-,NDTE P"Hy’ 7EII HOCHS1CHIULcTPASSE 2 6100 DAPMSTAOT PTA Monsieur DLILTZ HEI DRUN SCHMlITZER UINIVERSITAT-P11Y3K 0-84 PEGENSBIJRG PFA ...LOIIMANN 1UNIYEDRSTAT, PHY1,SiV >1aderrioiele SCHITZER UVVERSITY OF REGE.JSSL,: ROMMEL STR. 8520 ERLANGEN PFA 84 REGENSBURG RFA Monsieur MARTINI DFYLR

  20. The dosimetric impact of including the patient table in CT dose estimates

    NASA Astrophysics Data System (ADS)

    Nowik, Patrik; Bujila, Robert; Kull, Love; Andersson, Jonas; Poludniowski, Gavin

    2017-12-01

    The purpose of this study was to evaluate the dosimetric impact of including the patient table in Monte Carlo CT dose estimates for both spiral scans and scan projection radiographs (SPR). CT scan acquisitions were simulated for a Siemens SOMATOM Force scanner (Siemens Healthineers, Forchheim, Germany) with and without a patient table present. An adult male, an adult female and a pediatric female voxelized phantom were simulated. The simulated scans included tube voltages of 80 and 120 kVp. Spiral scans simulated without a patient table resulted in effective doses that were overestimated by approximately 5% compared to the same simulations performed with the patient table present. Doses in selected individual organs (breast, colon, lung, red bone marrow and stomach) were overestimated by up to 8%. Effective doses from SPR acquired with the x-ray tube stationary at 6 o’clock (posterior-anterior) were overestimated by 14-23% when the patient table was not included, with individual organ dose discrepancies (breast, colon, lung red bone marrow and stomach) all exceeding 13%. The reference entrance skin dose to the back were in this situation overestimated by 6-15%. These results highlight the importance of including the patient table in patient dose estimates for such scan situations.

  1. Release and disposal of materials during decommissioning of Siemens MOX fuel fabrication plant at Hanau, Germany

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koenig, Werner; Baumann, Roland

    2007-07-01

    In September 2006, decommissioning and dismantling of the Siemens MOX Fuel Fabrication Plant in Hanau were completed. The process equipment and the fabrication buildings were completely decommissioned and dismantled. The other buildings were emptied in whole or in part, although they were not demolished. Overall, the decommissioning process produced approximately 8500 Mg of radioactive waste (including inactive matrix material); clearance measurements were also performed for approximately 5400 Mg of material covering a wide range of types. All the equipment in which nuclear fuels had been handled was disposed of as radioactive waste. The radioactive waste was conditioned on the basismore » of the requirements specified for the projected German final disposal site 'Schachtanlage Konrad'. During the pre-conditioning, familiar processes such as incineration, compacting and melting were used. It has been shown that on account of consistently applied activity containment (barrier concept) during operation and dismantling, there has been no significant unexpected contamination of the plant. Therefore almost all the materials that were not a priori destined for radioactive waste were released without restriction on the basis of the applicable legal regulations (chap. 29 of the Radiation Protection Ordinance), along with the buildings and the plant site. (authors)« less

  2. Differences of standard values of Supersonic shear imaging and ARFI technique - in vivo study of testicular tissue.

    PubMed

    Trottmann, M; Rübenthaler, J; Marcon, J; Stief, C G; Reiser, M F; Clevert, D A

    2016-01-01

    To investigate the difference of standard values of Supersonic shear imaging (SSI) and Acoustic Radiation Force Impulse (ARFI) technique in the evaluation of testicular tissue stiffness in vivo. 58 healthy male testes were examined using B-mode sonography and ARFI and SSI. B-mode sonography was performed in order to scan the testis for pathologies followed by performance of real-time elastography in three predefined areas (upper pole, central portion and lower pole) using the SuperSonic® Aixplorer ultrasound device (SuperSonic Imagine, Aix-en-Provence, France). Afterwards a second assessment of the same testicular regions by elastography followed using the ARFI technique of the Siemens Acuson 2000™ ultrasound device (Siemens Health Care, Germany). Values of shear wave velocity were described in m/s. Parameters of elastography techniques were compared using paired sample t-test. The values of SSI were all significantly higher in all measured areas compared to ARFI (p < 0.001 to p = 0.015). Quantitatively there was a higher mean SSI wave velocity value of 1,1 compared to 0.8 m/s measured by ARFI. SSI values are significantly higher than ARFI values when measuring the stiffness of testicular tissue and should only be compared with caution.

  3. 76 FR 59167 - Siemens Medical Solutions USA, Inc., Oncology Care Systems Division, Concord, CA; Siemens Medical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-23

    ... Medical Solutions USA, Inc., Oncology Care Systems Division, Concord, CA; Siemens Medical Solutions USA... Solutions USA, Inc. (Siemens), Oncology Care Systems Division, Concord, California (subject firm). The...., Oncology Care Systems Division, Concord, California (TA-W-73,158) and Siemens Medical Solutions USA, Inc...

  4. Prevalence of sarcopenic obesity in Germany using established definitions: Baseline data of the FORMOsA study.

    PubMed

    Kemmler, W; von Stengel, S; Engelke, K; Sieber, C; Freiberger, E

    2016-01-01

    The prevalence of sarcopenic obesity in community-dwelling women 70 years and older according to established sarcopenia and obesity definitions averaged between 0 and 2.3 % and can thus be considered as relatively low. However, the converse argument that sarcopenic obesity was incompatible with an independent life cannot be confirmed. The primary aim of the study was to determine the prevalence of sarcopenic obesity (SO) in community-dwelling (CD) older females in Germany. The secondary aim was to assess whether these females really live independently and autonomously. A total of 1325 CD females 70 years and older living in the area of Erlangen-Nürnberg, Germany were assessed. Sarcopenia as defined by (a) the European Working Group on Sarcopenia in older people (EWGSOP) and (b) the International working group on Sarcopenia (IWGS) combined with obesity defined as (a) BMI ≥ 30 kg/m(2) (NIH) or (b) body-fat ≥ 35 % (WHO) was determined. In participants with SO, Barthel Index, care level and social network were retrospectively evaluated via personal interview. Based on anthropometric data, family, education and social status, lifestyle, number and distribution of diseases and medication, the present cohort is representative for the corresponding German population. Sarcopenia prevalence was 4.5 % according to EWGSOP and 3.3 % according to the IWGS criteria. Obesity prevalence in our cohort averaged 19.8 % (BMI, NIH) and 63.8 % (body fat, WHO). The overlap between both factors (i.e. SO) ranged from 0 % (EWGSOP + NIH criteria) to 2.3 % (EWGSOP + WHO criteria). Factors that may represent limited autonomy or independence were very rarely identified in this SO cohort. The prevalence of sarcopenic obesity in the CD (female) German population 70 years + is relatively low. With respect to our second research aim, the hypothesis that SO was incompatible with independent life was rejected. However, the latter finding should be addressed with more dedicated study designs.

  5. Skin symptoms in four ectodermal dysplasia syndromes including two case reports of Rapp-Hodgkin-Syndrome.

    PubMed

    Knaudt, Björn; Volz, Thomas; Krug, Markus; Burgdorf, Walter; Röcken, Martin; Berneburg, Mark

    2012-01-01

    The skin, hair and nail changes in four distinct ectodermal dysplasia syndromes are compared and reviewed. These syndromes comprise Christ-Siemens-Touraine syndrome; ectrodactyly, ectodermal dysplasia and cleft lip/palate syndrome; ankyloblepharon-ectodermal defects-cleft lip/palate syndrome and Rapp-Hodgkin syndrome. A comprehensive overview of the dermatological signs and symptoms in these syndromes was generated from the database of the Ectodermal Dysplasia Network Germany, the clinical findings in the patients seen in our department and an extensive review of the literature. The findings included abnormalities of skin, sweating, hair and nails. These clinical findings are discussed in relation to the underlying molecular defects known to play a role in these four ectodermal dysplasia syndromes.

  6. [Early contributions from Erlangen to the theory and practice of ether and chloroform anesthesia. 1. Heyfelder's clinical trial with ether and chloroform].

    PubMed

    Hintzenstern, U v; Schwarz, W

    1996-02-01

    The era of modern anaesthesia in Germany began on January 24th, 1847. This day, professor in ordinary Johann Ferdinand Heyfelder anaesthetized a patient with sulphuric ether in the clinic of surgery and ophthalmology of the University of Erlangen. By March 17th, 1847, Heyfelder had performed 121 surgical procedures under ether. The operations in majority were teeth-extractions, and a few more complex operations such as the treatment of a harelip or of lip cancer or the resection of the shoulder joint. Heyfelder described in detail 108 of these inhalations in a little book entitled The experiments with sulphuric ether. This monograph published in March, 1847, represents one of the first complete dissertations on sulphuric ether in the German literature. In a special chapter he analyzed the development of various physiological and psychological parameters during etherization. Heyfelder also examined blood and urine of some etherized patients and reported that he did not find any important or specific alterations. In 1847, Heyfelder was probably the first to apply salt-ether in man. After 4 administrations he concluded that salt ether acted more quickly but shorter than sulphuric ether. Advantageous were its application without problems and ease of induction. Disadvantageous were its high volatility, its price and the difficulty of getting it in a pure form. From December, 1847, on Heyfelder started to use chloroform. He was now able to perform more major operations, for example, the total resection of the hip-joint. In his book The experiments with sulphuric ether, salt ether, and chloroform he describes a great number of anaesthetic administrations using these 3 agents. In his summary Heyfelder concluded, that chloroform was undoubtly superior to sulphuric ether mainly because it was a quicker acting and longer lasting agent and leads to deeper narcosis. Moreover its application was much easier for it needed no special apparatus. However, because of its great anaesthetic potency, Heyfelder particularly demanded great caution in the application of chloroform. Explicitely he expected an assistant for chloroformizations, whose only duty was to supervise the inhalations and the patient--a forerunner of the modern specialized anaesthesiologist.

  7. Exercise and fractures in postmenopausal women. Final results of the controlled Erlangen Fitness and Osteoporosis Prevention Study (EFOPS).

    PubMed

    Kemmler, W; Bebenek, M; Kohl, M; von Stengel, S

    2015-10-01

    The EFOPS trial clearly established the positive effect of long-term exercise on clinical low-trauma fractures in postmenopausal women at risk. Bearing in mind that the complex anti-fracture exercise protocols also affect a large variety of diseases of increased age, we strongly encourage older adults to perform multipurpose exercise programs. Physical exercise may be an efficient option for autonomous fracture prevention during increasing age. The aim of the study was to evaluate the effect of exercise on clinical overall fracture incidence and bone mineral density (BMD) in elderly subjects at risk. In 1998 initially, 137 early-postmenopausal, osteopenic women living in Erlangen-Nuremberg, Germany, were included in the EFOPS trial. Subjects of the exercise group (EG; n = 86) conducted two supervised group and two home exercise sessions/week while the control group (CG; n = 51) was requested to maintain their physical activity. Primary study endpoints were clinical overall low-trauma fractures determined by questionnaires, structured interviews, and BMD at the lumbar spine and femoral neck assessed by dual-energy X-ray absorptiometry. In 2014, 105 subjects (EG: n = 59 vs. CG: n = 46) representing 1680 participant-years were included in the 16-year follow-up analysis. Risk ratio in the EG for overall low-trauma fractures was 0.51 (95% confidence interval (95% CI) 0.23 to 0.97, p = .046), rate ratio was 0.42 (95% CI 0.20 to 0.86, p = .018). Based on comparable baseline values, lumbar spine (MV -1.5%, 95% CI -0.1 to -2.8 vs. -5.8%, -3.3 to -7.2%) and femoral neck (-6.5%, -5.2 to -7.7 vs. -9.6%, -8.2 to 11.1%) BMD decreased in both groups; however, the reduction was more pronounced in the CG (p ≤ .001). This study clearly evidenced the high anti-fracture efficiency of multipurpose exercise programs. Considering furthermore the favorable effect of exercise on most other risk factors of increasing age, we strongly encourage older adults to perform multipurpose exercise programs.

  8. Upfront dilution of ferritin samples to reduce hook effect, improve turnaround time and reduce costs.

    PubMed

    Wu, Shu Juan; Hayden, Joshua A

    2018-02-15

    Sandwich immunoassays offer advantages in the clinical laboratory but can yield erroneously low results due to hook (prozone) effect, especially with analytes whose concentrations span several orders of magnitude such as ferritin. This study investigated a new approach to reduce the likelihood of hook effect in ferritin immunoassays by performing upfront, five-fold dilutions of all samples for ferritin analysis. The impact of this change on turnaround time and costs were also investigated. Ferritin concentrations were analysed in routine clinical practice with and without upfront dilutions on Siemens Centaur® XP (Siemens Healthineers, Erlang, Germany) immunoanalysers. In addition, one month of baseline data (1026 results) were collected prior to implementing upfront dilutions and one month of data (1033 results) were collected after implementation. Without upfront dilutions, hook effect was observed in samples with ferritin concentrations as low as 86,028 µg/L. With upfront dilutions, samples with ferritin concentrations as high as 126,050 µg/L yielded values greater than the measurement interval and would have been diluted until an accurate value was obtained. The implementation of upfront dilution of ferritin samples led to a decrease in turnaround time from a median of 2 hours and 3 minutes to 1 hour and 18 minutes (P = 0.002). Implementation of upfront dilutions of all ferritin samples reduced the possibility of hook effect, improved turnaround time and saved the cost of performing additional dilutions.

  9. 78 FR 19017 - Manufacturer of Controlled Substances; Notice of Registration; Siemens Healthcare Diagnostics, Inc.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-28

    ...; Notice of Registration; Siemens Healthcare Diagnostics, Inc. By Notice dated November 27, 2012, and published in the Federal Register on December 5, 2012, 77 FR 72409, Siemens Healthcare Diagnostics Inc... Siemens Healthcare Diagnostics Inc., to manufacture the listed basic classes of controlled substances is...

  10. Association of β-defensin copy number and psoriasis in three cohorts of European origin

    PubMed Central

    Stuart, Philip E; Hüffmeier, Ulrike; Nair, Rajan P; Palla, Raquel; Tejasvi, Trilokraj; Schalkwijk, Joost; Elder, James T; Reis, Andre; Armour, John AL

    2012-01-01

    A single previous study has demonstrated significant association of psoriasis with copy number of beta-defensin genes, using DNA from psoriasis cases and controls from Nijmegen and Erlangen. In this study we attempted to replicate that finding in larger new cohorts from Erlangen (N = 2017) and Michigan (N = 5412), using improved methods for beta-defensin copy number determination based on the paralog ratio test (PRT), and enhanced methods of analysis and association testing implemented in the CNVtools resource. We demonstrate that the association with psoriasis found in the discovery sample is maintained after applying improved typing and analysis methods (p = 5.5 × 10−4, OR = 1.25). We also find that the association is replicated in 2616 cases and 2526 controls from Michigan, although at reduced significance (p = 0.014), but not in new samples from Erlangen (1396 cases and 621 controls, p = 0.38). Meta-analysis across all cohorts suggests a nominally significant association (p = 6.6 × 10−3/2 × 10−4) with an effect size (OR = 1.081) much lower than found in the discovery study (OR = 1.32). This reduced effect size and significance on replication is consistent with a genuine but weak association. PMID:22739795

  11. The MIRAX Hard X-ray Transient Mission

    NASA Astrophysics Data System (ADS)

    Braga, João; Grindlay, Josh; Rothschild, Rick; Wilms, Joern; Remillard, Ron

    2012-09-01

    The MIRAX (Monitor e Imageador de Raios X) mission is designed to perform a hard X-ray (5-200 keV) survey of more than half of the sky with high localization power (~1') and high sensitivity (26 mCrab for one orbit and 0.3 mCrab for one year). This will be achieved by a set of 4 coded-mask imagers that will operate in scanning mode in a near-Equatorial circular LEO. The pointing directions will maximize the coverage of the Central Galactic Plane. The detectors are position-sensitive 5mm-thick CdZnTe with 0.6mm pitch with 756 square cm effective area at 10 keV (total for the 4 units). The energy resolution is ~2 keV at 60 keV. The main objective of MIRAX is to study with unprecedented depth and time coverage (milliseconds to years) a large sample of transient and variable phenomena on accreting neutron stars and black holes. The satellite bus and launch will be provided by Brazil, whereas the instrument development is a cooperative effort led by CfA, including INPE(Brazil), UCSD, MIT, GSFC, Caltech and the Univ. of Erlangen-Nuremberg in Germany.

  12. A 3D morphometric follow-up analysis after frontoorbital advancement in non-syndromic craniosynostosis.

    PubMed

    Martini, M; Schulz, M; Röhrig, A; Nadal, J; Messing-Jünger, M

    2015-10-01

    Frontoorbital advancement (FOA) in patients with non-syndromic craniosynostosis mainly addresses the aesthetic and functional correction of the frontoorbital region. To help define the operative strategy and any follow-up assessments after surgical correction, objective parameters describing the critical regions of skull deformity are essential. Based on 3D morphometric analysis, new parameters for the documentation of changes of the frontoorbital bandeau were developed in a prospective study. In a prospective series, 13 children with non-syndromic craniosynostosis (seven metopic, four unilateral coronal, and two bilateral coronal) treated with frontoorbital advancement, underwent detailed morphometric and volumetric evaluation using a 3D light optical scan system (3D-Shape, Erlangen, Germany). Measurements were obtained preoperatively and at 3, 6 and 12 months postoperatively with newly developed parameters generated by cephalometric analysis software (Onyx Ceph, Image Instruments, Chemnitz, Germany). In most patients, frontoorbital advancement resulted in stable long-term results without growth inhibition and with normalization or improvement of ongoing skull development. The mean frontal angle was 145° and the frontoparietal angle 137-140°. The cephalic index was normalized or markedly improved. Head circumference and head height increased significantly (p = 0.001 and p = 0.002, respectively). These changes were confirmed in all postoperative measurements. During the 12-month follow-up period all angle parameters proved to be stable and no major impairment of normal skull growth was observed after FOA. The frontoorbital angle is a useful parameter in evaluating long-term outcome. The frontoparietal angle is important for the stability of the frontoparietal region, in which a certain growth inhibition may be observed postoperatively. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. [Stability of long-term professional objectives of young physicians during postgraduate training. Results of a multicenter cohort study].

    PubMed

    Birck, S; Gedrose, B; Robra, B-P; Schmidt, A; Schultz, J-H; Stosch, C; Wagner, R; Janßen, N; Scherer, M; van den Bussche, H

    2014-10-01

    We investigated persistences and changes of career preferences of medical residents in Germany after two years of postgraduate training with regard to future working place and position. The results are compared with those forwarded at graduation from medical school in a gender comparative perspective. The study is based on a standardized postal survey among the participants in the "KarMed" study, originally based on 1012 graduates of the medical faculties of Erlangen, Giessen, Hamburg, Heidelberg, Cologne, Leipzig and Magdeburg in 2009. 2107 persons were contacted. The return rate at baseline was 48 %, and the two surveys after the baseline reached return rates of 87 % and 89 % respectively. In all samples 2/3 were women as in actual medical undergraduate education. Descriptive statistics and regression analysis were performed. After 2 years of residency, residents after 2 years of postgraduate training still preferred the hospital over private practice as their final workplace after postgraduate training. The attractiveness of leading positions in the hospital declined among men, whereas it was already low for women at graduation. A large proportion of those physicians preferring the ambulatory sector, especially women, wishes to work as employee instead of private practice. At the personal level, almost 60 % forwarded the same preferences as those at graduation. Gender, parenthood and region of study (East vs. West Germany) did not influence stability or change of preferences. The results demonstrate the persistence of professional preferences regarding future sector and position of medical work during postgraduate training. These preferences do neither match with principles of gender equality nor with future workforce needs (e. g. in primary care). © Georg Thieme Verlag KG Stuttgart · New York.

  14. Klein-Weyl's program and the ontology of gauge and quantum systems

    NASA Astrophysics Data System (ADS)

    Catren, Gabriel

    2018-02-01

    We distinguish two orientations in Weyl's analysis of the fundamental role played by the notion of symmetry in physics, namely an orientation inspired by Klein's Erlangen program and a phenomenological-transcendental orientation. By privileging the former to the detriment of the latter, we sketch a group(oid)-theoretical program-that we call the Klein-Weyl program-for the interpretation of both gauge theories and quantum mechanics in a single conceptual framework. This program is based on Weyl's notion of a "structure-endowed entity" equipped with a "group of automorphisms". First, we analyze what Weyl calls the "problem of relativity" in the frameworks provided by special relativity, general relativity, and Yang-Mills theories. We argue that both general relativity and Yang-Mills theories can be understood in terms of a localization of Klein's Erlangen program: while the latter describes the group-theoretical automorphisms of a single structure (such as homogenous geometries), local gauge symmetries and the corresponding gauge fields (Ehresmann connections) can be naturally understood in terms of the groupoid-theoretical isomorphisms in a family of identical structures. Second, we argue that quantum mechanics can be understood in terms of a linearization of Klein's Erlangen program. This stance leads us to an interpretation of the fact that quantum numbers are "indices characterizing representations of groups" ((Weyl, 1931a), p.xxi) in terms of a correspondence between the ontological categories of identity and determinateness.

  15. Solid Oxide Fuel Cells Operating on Alternative and Renewable Fuels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Xiaoxing; Quan, Wenying; Xiao, Jing

    2014-09-30

    This DOE project at the Pennsylvania State University (Penn State) initially involved Siemens Energy, Inc. to (1) develop new fuel processing approaches for using selected alternative and renewable fuels – anaerobic digester gas (ADG) and commercial diesel fuel (with 15 ppm sulfur) – in solid oxide fuel cell (SOFC) power generation systems; and (2) conduct integrated fuel processor – SOFC system tests to evaluate the performance of the fuel processors and overall systems. Siemens Energy Inc. was to provide SOFC system to Penn State for testing. The Siemens work was carried out at Siemens Energy Inc. in Pittsburgh, PA. Themore » unexpected restructuring in Siemens organization, however, led to the elimination of the Siemens Stationary Fuel Cell Division within the company. Unfortunately, this led to the Siemens subcontract with Penn State ending on September 23rd, 2010. SOFC system was never delivered to Penn State. With the assistance of NETL project manager, the Penn State team has since developed a collaborative research with Delphi as the new subcontractor and this work involved the testing of a stack of planar solid oxide fuel cells from Delphi.« less

  16. Molecular analysis of rubella virus in travelers suspected of measles infection in São Paulo, Brazil.

    PubMed

    Figueiredo, Cristina A; Yu, Ana Lucia Frugis; Afonso, Ana Maria S; Curti, Suely P; Oliveira, Maria I

    2012-01-01

    To identify measles virus genotypes in three cases of travelers suspected of measles infection. Samples (blood and urine) were collected for serology, virus isolation, and genotyping. Sera were analyzed for IgM antibodies against measles virus and rubella virus by enzyme-linked immunosorbent assay (ELISA) (Siemens - Marburg, Germany). Clinical samples (lymphocytes and urine) were inoculated into Statens Serum Institute rabbit corneal epithelial cell line- ATCC CL 60 (SIRC) and Vero Slam cells. RNA was extracted from clinical samples and cell culture was inoculated and processed by polymerase chain reaction (PCR) with oligonucleotides specific for measles virus (MV) and rubella virus (RV). All patients showed IgM negative serology for MV and positive IgM for RV. RV belonging to genotypes 1B, 1C, and 1E were isolated from patients who came from Finland, Peru, and Germany, respectively. Genotype 1B has been found in Europe and on the East Coast of South America; 1C has been found in Peru and the West Coast of South America, and 1E, first identified in 1997, now appears to have worldwide distribution. Information about RV and MV genotypes circulating in São Paulo is essential for the control of measles, rubella, and congenital rubella syndrome (CRS) in Brazil.

  17. 76 FR 51402 - Manufacturer of Controlled Substances; Notice of Registration

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-18

    ..., 2011, 76 FR 25375, Siemens Healthcare Diagnostics Inc., Attn: RA, 100 GBC Drive, Mail Stop 514, Newark.... 823(a) and determined that the registration of Siemens Healthcare Diagnostics Inc., to manufacture the... has investigated Siemens Healthcare Diagnostics Inc., to ensure that the company's registration is...

  18. 77 FR 30518 - Town of Springfield, Vermont and Siemens Westinghouse Technical Services, Inc., One Hundred River...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-23

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 9648-018] Town of Springfield, Vermont and Siemens Westinghouse Technical Services, Inc., One Hundred River Street, LLC; Notice... 15, 2011 and supplemented on April 27, 2012, the Town of Springfield, Vermont and Siemens...

  19. 75 FR 69466 - Manufacturer of Controlled Substances; Notice of Registration

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-12

    ..., 2010, (75 FR 20001), Siemens Healthcare Diagnostics Inc., Attn: RA, 100 GBC Drive, Mail Stop 514... Siemens Healthcare Diagnostics Inc. to manufacture the listed basic classes of controlled substances is consistent with the public interest at this time. DEA has investigated Siemens Healthcare Diagnostics Inc. to...

  20. 77 FR 31390 - Manufacturer of Controlled Substances; Notice of Registration; Siemens Healthcare Diagnostics, Inc.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-25

    ...; Notice of Registration; Siemens Healthcare Diagnostics, Inc. By Notice dated January 26, 2012, and published in the Federal Register on February 6, 2012, 77 FR 5847, Siemens Healthcare Diagnostics Inc., 100... Healthcare Diagnostics Inc., to manufacture the listed basic classes of controlled substances is consistent...

  1. 77 FR 72409 - Manufacturer of Controlled Substances; Notice of Application: Siemens Healthcare Diagnostics, Inc.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-05

    ... DEPARTMENT OF JUSTICE Drug Enforcement Administration Manufacturer of Controlled Substances; Notice of Application: Siemens Healthcare Diagnostics, Inc. Pursuant to Sec. 1301.33(a) Title 21 of the Code of Federal Regulations (CFR), this is notice that on November 7, 2012, Siemens Healthcare...

  2. Fast vessel segmentation in retinal images using multi-scale enhancement and second-order local entropy

    NASA Astrophysics Data System (ADS)

    Yu, H.; Barriga, S.; Agurto, C.; Zamora, G.; Bauman, W.; Soliz, P.

    2012-03-01

    Retinal vasculature is one of the most important anatomical structures in digital retinal photographs. Accurate segmentation of retinal blood vessels is an essential task in automated analysis of retinopathy. This paper presents a new and effective vessel segmentation algorithm that features computational simplicity and fast implementation. This method uses morphological pre-processing to decrease the disturbance of bright structures and lesions before vessel extraction. Next, a vessel probability map is generated by computing the eigenvalues of the second derivatives of Gaussian filtered image at multiple scales. Then, the second order local entropy thresholding is applied to segment the vessel map. Lastly, a rule-based decision step, which measures the geometric shape difference between vessels and lesions is applied to reduce false positives. The algorithm is evaluated on the low-resolution DRIVE and STARE databases and the publicly available high-resolution image database from Friedrich-Alexander University Erlangen-Nuremberg, Germany). The proposed method achieved comparable performance to state of the art unsupervised vessel segmentation methods with a competitive faster speed on the DRIVE and STARE databases. For the high resolution fundus image database, the proposed algorithm outperforms an existing approach both on performance and speed. The efficiency and robustness make the blood vessel segmentation method described here suitable for broad application in automated analysis of retinal images.

  3. [A journey into the (un)known. Borderlands of knowledge for Leonhard Rauwolf (1535?-1596)].

    PubMed

    Walter, Tilmann

    2009-01-01

    The Augsburg physician Leonhard Rauwolf is known to the history of Western sciences for "discovering" the exotic flora of the Near East. This article deals with the social background of his studies in Germany and France and his perception of foreign lands, plants, and peoples. Before Rauwolf started his journey at Marseille in 1573 he had received a proper education in practical botany at Montpellier under Guillaume Rondelet. He had also collected about 600 specimens of plants in his herbarium. According to the common medical conventions of his time--most prominently represented by the Renaissance anatomist Andreas Vesalius--in his travel account Rauwolf claimed to tell only what he had seen, experienced, observed by himself, or touched with his own hands. Contrary to his own claim of pure "autopsy", or direct experience, however, Rauwolf's Aigentliche Beschreibung [Actual Description] was composed from different sources. As previously unnoted manuscript letters from the Trew-collection at the University Library of Erlangen show, editorial work on Rauwolf's book was a lengthy process. The final composition ended up drawing on such different sources as the Old and New Testament, ancient natural philosophy, Christian travel literature and sermons, more recent botanical books, oral information from other academics, fellow travellers or indigenous people, and--finally--Rauwolf's own mpressions and observations.

  4. αvß3-Integrin-Targeted Magnetic Resonance Imaging for the Assessment of Early Antiangiogenic Therapy Effects in Orthotopic Breast Cancer Xenografts.

    PubMed

    Kazmierczak, Philipp Maximilian; Schneider, Moritz; Habereder, Thomas; Hirner-Eppeneder, Heidrun; Eschbach, Ralf S; Moser, Matthias; Reiser, Maximilian F; Lauber, Kirsten; Nikolaou, Konstantin; Cyran, Clemens C

    2016-11-01

    The aim of this study was to investigate magnetic resonance imaging (MRI) with αvß3-integrin-targeted ultrasmall superparamagnetic iron oxide nanoparticles (RGD-USPIO) for the in vivo monitoring of early antiangiogenic therapy effects in experimental breast cancer. Orthotopic human breast cancer (MDA-MB-231) xenograft-bearing severe combined immunodeficiency mice were imaged before and after a 1-week therapy with the vascular endothelial growth factor receptor-antibody bevacizumab or placebo (n = 10 per group, daily intraperitoneal injections of bevacizumab or a volume-equivalent placebo solution, respectively) on a clinical 3 T scanner (Magnetom Skyra; Siemens Healthcare, Erlangen, Germany) before and 60 minutes after the intravenous injection of RGD-USPIO (P04000; Guerbet, Villepinte, France). R2 relaxometry employing a T2-weighted spin-echo sequence with 4 echo times (echo time, 20/40/60/80 milliseconds; repetition time, 3800 milliseconds; matrix, 128 × 128; field of view, 50 × 50; slice thickness, 1.2 mm; time to acquisition, 25 minutes) was used as semiquantitative measure to determine RGD-USPIO endothelial binding. In addition, the T2-weighted images were used to perform volumetric tumor response assessments. Imaging results were validated by ex vivo multiparametric immunohistochemistry with regard to αvß3-integrin expression, microvascular density (CD31), proliferation (Ki-67), and apoptosis (TUNEL). RGD-USPIO endothelial binding was significantly reduced after vascular endothelial growth factor inhibition, compared with the control group in which an increased endothelial binding was detected ([INCREMENT]R2Therapy = -0.80 ± 0.78 s; [INCREMENT]R2Control = +0.27 ± 0.59 s; P = 0.002). Correspondingly, immunohistochemistry revealed a significantly lower αvß3-integrin expression (91 ± 30 vs 357 ± 72; P < 0.001), microvascular density (CD31, 109 ± 46 vs 440 ± 208; P < 0.001), tumor cell proliferation (Ki-67, 4040 ± 1373 vs 6530 ± 1217; P < 0.001), as well as significantly higher apoptosis (TUNEL, 11186 ± 4387 vs 4017 ± 1191; P = 0.004) in the therapy compared with the control group. Contrary to the changes in αvß3-integrin expression detected by RGD-USPIO MRI, morphology-based tumor response assessments did not show a significant intergroup difference in tumor volume development over the course of the experiment (ΔVolTherapy +71 ± 40 μL vs ΔVolControl +125 ± 81 μL; P > 0.05). RGD-USPIO MRI allows for the noninvasive assessment of αvß3-integrin expression in the investigated breast cancer model. RGD-USPIO MRI may be applicable for the in vivo monitoring of early antiangiogenic therapy effects in experimental breast cancer, generating possible complementary molecular imaging biomarkers to morphology-based tumor response assessments.

  5. Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy.

    PubMed

    Low, D A; Dempsey, J F; Venkatesan, R; Mutic, S; Markman, J; Mark Haacke, E; Purdy, J A

    1999-08-01

    BANG gel (MGS Research, Inc., Guilford, CT) has been evaluated for measuring intensity-modulated radiation therapy (IMRT) dose distributions. Treatment plans with target doses of 1500 cGy were generated by the Peacock IMRT system (NOMOS Corp., Sewickley, PA) using test target volumes. The gels were enclosed in 13 cm outer diameter cylindrical glass vessels. Dose calibration was conducted using seven smaller (4 cm diameter) cylindrical glass vessels irradiated to 0-1800 cGy in 300 cGy increments. Three-dimensional maps of the proton relaxation rate R2 were obtained using a 1.5 T magnetic resonance imaging (MRI) system (Siemens Medical Systems, Erlangen, Germany) and correlated with dose. A Hahn spin echo sequence was used with TR = 3 s, TE = 20 and 100 ms, NEX = 1, using 1 x 1 x 3 mm3 voxels. The MRI measurements were repeated weekly to identify the gel-aging characteristics. Ionization chamber, thermoluminescent dosimetry (TLD), and film dosimetry measurements of the IMRT dose distributions were obtained to compare against the gel results. The other dosimeters were used in a phantom with the same external cross-section as the gel phantom. The irradiated R2 values of the large vessels did not precisely track the smaller vessels, so the ionization chamber measurements were used to normalize the gel dose distributions. The point-to-point standard deviation of the gel dose measurements was 7.0 cGy. When compared with the ionization chamber measurements averaged over the chamber volume, 1% agreement was obtained. Comparisons against radiographic film dose distribution measurements and the treatment planning dose distribution calculation were used to determine the spatial localization accuracy of the gel and MRI. Spatial localization was better than 2 mm, and the dose was accurately determined by the gel both within and outside the target. The TLD chips were placed throughout the phantom to determine gel measurement precision in high- and low-dose regions. A multidimensional dose comparison tool that simultaneously examines the dose-difference and distance-to-agreement was used to evaluate the gel in both low-and high-dose gradient regions. When 3% and 3 mm criteria were used for the comparisons, more than 90% of the TLD measurements agreed with the gel, with the worst of 309 TLD chip measurements disagreeing by 40% of the criteria. All four MRI measurement session gel-measured dose distributions were compared to evaluate the time behavior of the gel. The low-dose regions were evaluated by comparison with TLD measurements at selected points, while high-dose regions were evaluated by directly comparing measured dose distributions. Tests using the multidimensional comparison tool showed detectable degradation beyond one week postirradiation, but all low-dose measurements passed relative to the test criteria and the dose distributions showed few regions that failed.

  6. 76 FR 50269 - Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-12

    ... Solutions USA, Inc., Oncology Care Systems Division, Concord, CA TA-W-73,158A Siemens Medical Solutions USA... and former workers of Siemens Medical Solutions USA, Inc. (Seimens), Oncology Care Systems Division... issued as follows: All workers of Siemens Medical Solutions USA, Inc., Oncology Care Systems Division...

  7. ETV Report: Siemens Model V-40R-A150 Open Channel UV System

    EPA Science Inventory

    Verification testing of the Siemens Barrier Sunlight V-40R-A150 UV System was completed at the UV Validation and Research Center of New York (UV Center), located in Johnstown, NY. The V-40R System supplied by Siemens utilizes 40 high-output, low-pressure amalgam lamps, oriented ...

  8. 78 FR 41911 - Foreign-Trade Zone 161-Sedgwick County, Kansas; Authorization of Production Activity; Siemens...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-12

    ... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [B-27-2013] Foreign-Trade Zone 161--Sedgwick County, Kansas; Authorization of Production Activity; Siemens Energy, Inc. (Wind Turbine Nacelles and Hubs); Hutchinson, Kansas On March 7, 2013, Siemens Energy, Inc., an operator of FTZ 161, submitted a notification of proposed production activity to...

  9. [Remember, Avert, Prevent: Franz Ludwig Berthold Kihn--A Typology of "Euthanasia"].

    PubMed

    Braun, B; Frewer, A; Kornhuber, J

    2015-11-01

    The current debate on assisted suicide provides the occasion for calling to mind the role of Berthold Kihn as a psychiatrist under National Socialism. With a historical presentation of a typology of euthanasia, the Academic Psychiatry of Erlangen together with the Medical Ethics would like to sensitize discussions on assisted suicide by drawing attention to the start and end of Kihn's scientific career. Relevant archive material, primary and secondary literature were analyzed and evaluated. As Assistant and Senior Physician at the Psychiatric and Neurological Hospital of the University of Erlangen, Kihn lectured on "the elimination of the inferiors". As Director of the Psychiatric and Neurological Hospital of Jena University, Kihn selected psychiatric patients to be murdered under the "T4 action". Kihn participated in drafting a "Euthanasia Law". Despite his involvement in the murder of mentally ill, Kihn returned to Erlangen as a "Soviet Zone refugee", where a Denazification Court considered him a "hanger-on". Kihn was reintegrated in the academic faculty of the Friedrich-Alexander-University and headed a private clinic. On 21.01.1963, the State's Attorney Nuremberg-Fuerth dropped the criminal procedure against Kihn--officially due to a lack of proof of punishable guilt. An appropriate medical historical contextualization can represent an important condition for an adequate medical ethical debate on physician-assisted suicide and the involvement of psychiatrists. FINAL COMMENT: The analysis of Kihn's patterns of thought and argumentation can help sensitize those involved in debates on physician-assisted suicide and highlights the critical role of psychiatry as a discipline in this context. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Advanced mask cleaning for 0.20-μm technology: an integrated user-supplier approach

    NASA Astrophysics Data System (ADS)

    Poschenrieder, Rudolf; Hay, Bernd; Beier, Matthias; Hourd, Andrew C.; Stuemer, Harald; Gairing, Thomas M.

    1998-12-01

    A newly developed photomask final cleaning system, STEAG HamaTech's Advanced Single Substrate Cleaner, ASC 500, was assessed and optimized at the Siemens mask shop in Munich, Germany, under production conditions within the Esprit European Semiconductor Equipment Assessment programme (SEA). The project was carried out together with the active participation of Compugraphics Intl. Ltd. (UK), DuPont Photomasks, Inc. (Germany; Photronics-MZD, Germany). The results of the assessment are presented, focusing on the cleaning performance at the 0.25 micrometer defect level on photomasks, equipment reliability and Cost of Ownership data. A reticle free of soft defects on glass and on chrome down to the 0.25 micrometer level requires an excellent cleaning process and the use of high-end inspection tools like the KLA STARlight. In order to get a full understanding of the nature of the detected features additional investigations on the blank quality have been carried out. These investigations include the questions whether a detection is a hard or a soft defect and whether small defects on chrome are able to move on the reticle surface. Final cleaning recipes have been optimized in respect to cleaning efficiency while maintaining high throughput and low Cost of Ownership. A benchmark comparison against other final cleaning tools at the partner's maskshops showed the leading data of the ASC 500. It was found that a cleaning program which includes several substrate flips and a combination of the available cleaning methods acid- dispense, water pressure jet clean, brush and megasonic clean was best suitable to achieve these goals. In particular the use of the brush unit was shown to improve the yield while not adding damage to the plate.

  11. Sensitometric effects of varying the intensifying screens used with Agfa Dentus ST8G and RP6 panoramic radiographic films.

    PubMed

    Wakoh, M; Farman, A G; Scarfe, W C; Kitagawa, H; Kuroyanagi, K

    1997-07-01

    To compare the sensitometric effects and information yield of varying the intensifying screens used with both Dentus ST8G and RP6 Agfa Gevaert, Dormagen, Germany panoramic radiographic films. Four screen-film combinations were employed for each of the two film types. The screens used were blue fluorescing PX-III (Kasei Optonix, Tokyo, Japan) and Special (Siemens AG, Bensheim, Germany), as well as green fluorescing Lanex Regular (Eastman Kodak, Rochester, NY, USA) and Trimax T16 (3M, Mineapolis, Minnesota, USA). The density response for each screen-film combination was evaluated using the characteristic curves generated. Information yield, as determined by the radiographic detection of defects in an aluminium test object, was evaluated by nine observers. The characteristic curves for ST8G were different when green and blue fluorescing screens were used; however, those for RP6 varied little irrespective of the choice of intensifying screens. Observers were able to perceive defects at significantly lower radiation exposures for ST8G combined with green fluorescing screens compared with blue emitting screens. RP6 with all screen combinations provided similar image detail perceptibility at comparable exposures with ST8G with green-fluorescing screens. RP6 is suitable for use with either the spectrally matched blue emitting screens or green-emitting screens. ST8G radiographic film should always be matched to rare earth screens.

  12. Masticatory motion after surgical or nonsurgical treatment for unilateral fractures of the mandibular condylar process.

    PubMed

    Throckmorton, Gaylord S; Ellis, Edward; Hayasaki, Haruaki

    2004-02-01

    We sought to compare mandibular motion during mastication in patients treated in either an open or a closed fashion for unilateral fractures of the mandibular condylar process. Eighty-one male patients with unilateral condylar process fractures were treated either with (n = 37) or without (n = 44) surgical reduction and rigid fixation of their condylar process fractures. At 6 weeks, 6 months, 1 year, and 2 years after treatment, the subjects' chewing cycles were recorded using a magnetic sensor array (Sirognathograph; Siemens Corp, Bensheim, Germany) while chewing Gummi-Bears (HARIBO, Bonn, Germany) unilaterally on the same side as the fracture and on the opposite side. The chewing cycles were analyzed using a custom computer program, and the duration, excursive ranges, and 3-dimensional cycle shape were compared between the 2 treatment groups at each time interval using multilevel linear modeling statistics. The 2 treatment groups did not differ significantly for any measure of cycle duration or any excursive range (except lateral excursions at 1 year post-treatment) at any of the time intervals. However, the 3-dimensional cycle shapes of the 2 groups did differ significantly at all time intervals. Surgical correction of unilateral condylar process fractures has relatively little effect on the more standard measures (duration and excursive ranges) of masticatory function. However, surgical correction better normalizes opening incisor pathways during mastication on the side opposite the fracture.

  13. SU-E-T-509: Validation of the Use of OSLD for Carbon Beam Remote Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Summers, P; Lowenstein, J; Alvarez, P

    2014-06-01

    Purpose: To describe the commissioning of Aluminum Oxide Optically Stimulated Luminescent Dosimeters (OSLD) for the use in Carbon beam remote dosimetry for centers participating in NCI-funded cooperative group clinical trials. Methods: As Carbon therapy centers express interest in participating in cooperative group clinical trials, the Imaging and Radiation Oncology Core Group (IROC) Houston QA Center (formerly RPC) is developing a way to remotely monitor the machine output of these Carbon facilities. OSLD have been commissioned for photon, electron and proton dosimetry, so an experiment was designed to commission the same dosimeters for Carbon. OSLD were irradiated in a Carbon therapymore » beam produced by the Siemens synchrotron at the Heidelberg Ion Therapy facility in Heidelberg, Germany. The OSLD were placed in acrylic phantoms, imaged with a CT scanner, and plans were developed using the Siemens treatment planning system. The OSLD were irradiated in uniform fields with maximum energies of 216, 301, and 402 MeV and at dose levels of 50, 100, 200 and 300 cGy. Results: The response of the OSLD in the Carbon beam, as compared to the Cobalt-60 reference condition, required an energy correction of 1.85 to account for the particle correction. OSLD dose calculations typically have a linearity correction to account for the change in response relative to the change in dose delivered. However, the response of the OSLD in the Carbon beam was found to be independent of the dose level; thus the linearity correction is 1.00. Conclusion: IROC Houston has commissioned OSLD for the use of remote output checks for Carbon therapy facilities to help ensure consistency across clinical trial participants. Work supported by grant CA10953 (NCI, DHHS)« less

  14. Single-source dual-energy computed tomography: use of monoenergetic extrapolation for a reduction of metal artifacts.

    PubMed

    Mangold, Stefanie; Gatidis, Sergios; Luz, Oliver; König, Benjamin; Schabel, Christoph; Bongers, Malte N; Flohr, Thomas G; Claussen, Claus D; Thomas, Christoph

    2014-12-01

    The objective of this study was to retrospectively determine the potential of virtual monoenergetic (ME) reconstructions for a reduction of metal artifacts using a new-generation single-source computed tomographic (CT) scanner. The ethics committee of our institution approved this retrospective study with a waiver of the need for informed consent. A total of 50 consecutive patients (29 men and 21 women; mean [SD] age, 51.3 [16.7] years) with metal implants after osteosynthetic fracture treatment who had been examined using a single-source CT scanner (SOMATOM Definition Edge; Siemens Healthcare, Forchheim, Germany; consecutive dual-energy mode with 140 kV/80 kV) were selected. Using commercially available postprocessing software (syngo Dual Energy; Siemens AG), virtual ME data sets with extrapolated energy of 130 keV were generated (medium smooth convolution kernel D30) and compared with standard polyenergetic images reconstructed with a B30 (medium smooth) and a B70 (sharp) kernel. For quantification of the beam hardening artifacts, CT values were measured on circular lines surrounding bone and the osteosynthetic device, and frequency analyses of these values were performed using discrete Fourier transform. A high proportion of low frequencies to the spectrum indicates a high level of metal artifacts. The measurements in all data sets were compared using the Wilcoxon signed rank test. The virtual ME images with extrapolated energy of 130 keV showed significantly lower contribution of low frequencies after the Fourier transform compared with any polyenergetic data set reconstructed with D30, B70, and B30 kernels (P < 0.001). Sequential single-source dual-energy CT allows an efficient reduction of metal artifacts using high-energy ME extrapolation after osteosynthetic fracture treatment.

  15. Results from Operational Testing of the Siemens Smart Grid-Capable Electric Vehicle Supply Equipment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bennett, Brion

    2015-05-01

    The Idaho National Laboratory conducted testing and analysis of the Siemens smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from Siemens for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the Siemens smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormalmore » conditions testing, and charging of a plug-in vehicle.« less

  16. Ethical opinions and personal attitudes of young adults conceived by in vitro fertilisation.

    PubMed

    Siegel, S; Dittrich, R; Vollmann, J

    2008-04-01

    Today in vitro fertilisation (IVF) is a widespread and important technique of reproductive medicine. When the technique was first used, it was considered ethically controversial. This is the first study conducted of adult IVF-offspring in order to learn about their ethical opinions and personal attitudes towards this medical technology. We recruited the participants from the first cases of in vitro fertilisation in Germany at the Gynaecological Clinic of the University Hospital Erlangen. Our qualitative interview study consisted of in-depth, face-to-face interviews with 16 adults who had been conceived by IVF. Our data was analysed with methods of Grounded Theory. For these adults, the most important factor influencing their personal attitudes towards IVF was the knowledge that they were deeply wanted children. The artificiality of their conception seemed irrelevant for their ethical opinion. All participants mentioned that it was important for them to be informed about the circumstances of their conception by their parents. IVF seems to be a medical technique which, although it affects intimate aspects of human existence, can be integrated into the lives of the affected persons without any great difficulties. The findings suggest that parents should inform their children about their fertilisation at an early age and as part of a process over time, not only on a single occasion. Physicians should advise IVF-parents accordingly.

  17. [Manufacture of autologous serum eye drops for out-patient therapy : cooperation between ophthalmic clinic and transfusion medicine department].

    PubMed

    Dietrich, T; Weisbach, V; Seitz, B; Jacobi, C; Kruse, F E; Eckstein, R; Cursiefen, C

    2008-11-01

    Autologous serum eye drops are an important therapy option in severe ocular surface disorders and the therapeutic effectiveness has been demonstrated in many clinical studies. The production and use of autologous serum eye drops is strictly controlled by legal regulations in Germany: Both the German Medicines Act (AMG) and the Blood Transfusion Act regulate production, distribution and application, unless it is carried out by one person under controlled conditions in a hospital setting. In cooperation with the ophthalmic clinic and the department of transfusion medicine, a standard operating procedure (SOP) was developed and a license for production and delivery of autologous serum eye drops was obtained from the appropriate local authorities. The experiences of the first two years of practice were analyzed. By an interfaculty cooperation, the possibility of legal and feasible out-patient treatment with autologous eye drops has been established at the University Hospital Erlangen. From 07/2005 to 07/2007, there ware 240 prescriptions for autologous serum eye drops. Unexpectedly, a relatively high rate (3.3%) of patients with primarily unknown viral or bacterial infectious diseases were found, which were diagnosed during the screening. These patients had to be excluded from autologous serum eye drop therapy. The treatment with autologous serum eye drops in an out-patient setting is possible, when the infrastructure for manufacture and delivery is provided in accordance with existing regulations.

  18. The impact of parental knowledge and tanning attitudes on sun protection practice for young children in Germany.

    PubMed

    Gefeller, Olaf; Li, Jiang; Uter, Wolfgang; Pfahlberg, Annette B

    2014-05-05

    Public health campaigns have improved knowledge on UVR-associated skin cancer risk and increased sun protection awareness. However, tanned skin is still a common beauty ideal. The relationship between knowledge, attitudes and protective behavior is not fully understood yet. A population-based survey was thus performed in the district of Erlangen involving 2,619 parents of 3- to 6-year old children. By means of a self-administered standardized questionnaire parental knowledge about risk factors for skin cancer, their attitudes towards tanning and details of protective measures taken for their children were assessed. The study analyzed specifically the impact of parental tanning attitudes on sun-protective measures for their children while controlling for parental knowledge about skin cancer risk factors. While parental knowledge was significantly (inversely) associated with agreement to the statement "Tanned skin is healthy skin", this was not the case for "Tanning makes me look better". Overall, tanning affirmative attitudes were inversely associated with protective measures taken for the children, whereas parental knowledge had a positive impact on sun protection at the beach only. Multivariable analyses provided evidence for an effect of parental attitude on protective behavior independent of parental knowledge. Tanning attitudes and tanned skin as the misguided ideal of beauty need to be addressed in future public health campaigns to enhance the effectiveness of preventive activities in changing sun protective behavior.

  19. Implantation of ArtificialIris, a CustomFlex irisprosthesis, in a trauma patient with an Artisan lens

    PubMed Central

    Doroodgar, Farideh; Jabbarvand, Mahmoud; Niazi, Feizollah; Niazi, Sana; Sanginabadi, Azad

    2017-01-01

    Abstract Purpose: To evaluate probable complications of ArtificialIris implantation with iris fixated intraocular lens. Method: Development of photophobia, glare, and psychological strain during face-to-face communication in a 23-year-old man with a widespread traumatic iris defect terminate to make a decision for performing implantation of an ArtificialIris (Humanoptics, Erlangen, Germany) under the remnant iris without removing the patient's existing Artisan lens. Results: Without any intraoperative or postoperative complications, the patient's visual acuity increased by 1 line, the endothelial cell loss was comparable with the cell loss associated with standard cataract surgery, and the anterior-chamber depth and anterior-chamber anatomy did not change. At the final follow-up examination, the mean intraocular pressure did not differ from baseline, and we achieved high level of patient satisfaction and subjective vision improvement. We discuss the particular importance of considering the patient's expectations, the appropriate measurements, ways to perfect color evaluation, and the types of ArtificialIris products. Conclusion: The implantation of the ArtificialIris in patients with aphakic iris-supported lenses (ie, pre-existing Artisan lenses) is a feasible approach and a useful option for patients with thin irises and iris hypoplasia who are at risk of subluxation or the dislocation of the posterior-chamber intraocular lens (PCIOL), and also those with sclerally fixed PCIOLs. PMID:29137026

  20. Darwin als Sehhilfe für die Psychologie - Evolutionspsychologie

    NASA Astrophysics Data System (ADS)

    Schwab, Frank

    Im Folgenden geht es um Einäugige, stereoskopisches Sehen, weite und enge Horizonte, Monokel und Sonnenbrillen. Der Beitrag versucht die Metapher des Sehens und der Sehhilfen anzuwenden, um so zu verdeutlichen, welchen Gewinn die herkömmliche Psychologie durch die Verwendung einer Darwin'schen Brille erlangen kann.

  1. Obliteration dynamics in cerebral arteriovenous malformations after cyberknife radiosurgery: quantification with sequential nidus volumetry and 3-tesla 3-dimensional time-of-flight magnetic resonance angiography.

    PubMed

    Wowra, Berndt; Muacevic, Alexander; Tonn, Jörg-Christian; Schoenberg, Stefan O; Reiser, Maximilian; Herrmann, Karin A

    2009-02-01

    To investigate the time-dependent obliteration of cerebral arteriovenous malformations (cAVM) after CyberKnife radiosurgery (CKRS) (Accuray, Inc., Sunnyvale, CA) by means of sequential 3-T, 3-dimensional (3D), time-of-flight (TOF) magnetic resonance angiography (MRA), and volumetry of the arteriovenous malformation (AVM) nidus. In this prospective study, 3D TOF MRA was performed on 20 patients with cAVMs treated by single-fraction CKRS. Three-dimensional TOF MRA was performed on a 3-T, 32-channel magnetic resonance scanner (Magnetom TIM Trio; Siemens Medical Solutions, Erlangen, Germany) with isotropic voxel size at a spatial resolution of 0.6 x 0.6 x 0.6 mm3. The time-dependent relative decay of the transnidal blood flow evidenced by 3D TOF MRA was referred to as "obliteration dynamics." Volumetry of the nidus size was performed with OsiriX imaging software (OsiriX Foundation, Geneva, Switzerland). All patients had 3 to 4 follow-up examinations at 3- to 6-month intervals over a minimum follow-up period of 9 months. Subtotal obliteration was determined if the residual nidus volume was 5% or less of the initial nidus volume. Stata/IC software (Version 10.0; Stata Corp., College Station, TX) was used for statistical analysis and to identify potential factors of AVM obliteration. Regarding their clinical status, case history, and pretreatments, the participants of this study represent difficult-to-treat cAVM patients. The median nidus volume was 1.8 mL (range, 0.4-12.5 mL); the median minimum dose prescribed to the nidus was 22 Gy (range, 16-24 Gy) delivered to the 67% isodose line (range, 55-80%). CKRS was well tolerated, with complications in 2 patients. No further hemorrhages occurred after RS, except 1 small and clinically inapparent incident. The median follow-up period after RS was 25.0 months (range, 11.7-36.8 months). After RS, a statistically significant obliteration was observed in all patients. However, the obliteration dynamics of the cAVMs showed a pronounced variability, with 2 types of post-therapeutic behavior identified. cAVMs of Group A showed a faster reduction of transnidal blood flow than cAVMs in Group B. The median time to subtotal obliteration was 23.8 months for all patients, 11.6 months for patients in Group A, and 27.8 months for patients in Group B (P = 0.05). Logistic regression analysis revealed dose homogeneity and the circumscribed isodose to be the only variables (P < 0.01) associated with the obliteration dynamics in this study. The cumulative complete angiographic obliteration rate was 67% (95% confidence interval, 32-95%) 2 years after RS. The use of sequential 3D TOF MRA at 3 T and nidus volumetry enables a noninvasive quantitative assessment of the dynamic obliteration process induced by CKRS in cAVMs. This method may be helpful to identify factors related to AVM obliteration after RS when larger patient cohorts become available.

  2. First-in-man (FIM) experience with the Magnetic Medical Positioning System (MPS) for intracoronary navigation.

    PubMed

    Jeron, Andreas; Fredersdorf, Sabine; Debl, Kurt; Oren, Eitan; Izmirli, Alon; Peleg, Alexander; Nekovar, Anton; Herscovici, Adrian; Riegger, Günter A; Luchner, Andreas

    2009-11-01

    To investigate the safety and feasibility of a newly developed magnetic navigation system for intracoronary tracking. The MediGuide Medical Positioning System (MPS) is a navigation system that was developed to facilitate the navigation of enabled devices within the coronary tree using a magnetic tracking technology. The current prospective, non-randomised, single-centre, first-in-man study was conducted at Universitätsklinikum Regensburg (UKR), Germany on an MPS-enabled AXIOM Artis dFC coronary angiography system (Siemens AG, Forchheim, Germany). We enrolled 20 patients who required IVUS assessment or treatment of a single de novo target lesion in a native coronary artery. The performance was evaluated on a semi-quantitative one-to-five scale where a score of five indicates an excellent superimposition with the vessel and a score of one an unacceptable performance. The mean score for tracking as assessed by projection on life fluoroscopy was 4.89 and 3.58 as assessed by projection on recorded cine-loop. Length measurement of a 20 mm distance was significantly better with the MPS (mean deviation of 0.6 mm=3%) as compared to standard QCA (1.5 mm=8%, p<0.05). Creating a 3D reconstruction was possible in 13 out of 20 cases with an average score of 4.68. No adverse events occurred. The MediGuide Medical Positioning System is safe and feasible in man, facilitates intracoronary navigation and allows 3D reconstruction of the investigated coronary segment.

  3. Siemens, Philips megaproject to yield superchip in 5 years

    NASA Astrophysics Data System (ADS)

    1985-02-01

    The development of computer chips using complementary metal oxide semiconductor (CMOS) memory technology is described. The management planning and marketing strategy of the Philips and Siemens corporations with regard to the memory chip are discussed.

  4. [Haemolysis and turbidity influence on three analysis methods of quantitative determination of total and conjugated bilirubin on ADVIA 1650].

    PubMed

    Gobert De Paepe, E; Munteanu, G; Schischmanoff, P O; Porquet, D

    2008-01-01

    Plasma bilirubin testing is crucial to prevent the occurrence of neonatal kernicterus. Haemolysis may occur during sampling and interfere with bilirubin determination. Moreover, lipidic infusions may induce plasma lipemia and also interfere with bilirubin measurement. We evaluated the interference of haemolysis and lipemia with three methods of total and direct bilirubin measurement adaptated on an Advia 1650 analyser (Siemens Medical Solutions Diagnostics) : Synermed (Sofibel), Bilirubin 2 (Siemens) and Bilirubin Auto FS (Diasys). The measurement of total bilirubin was little affected by haemolysis with all three methods. The Bilirubin 2 (Siemens) method was the less sensitive to haemolysis even at low bilirubin levels. The measurement of conjugated bilirubin was significantly altered by low heamoglobin concentrations for Bilirubin Auto FS(R) (30 microM or 0,192 g/100 mL haemoglobin) and for Synermed (60 microM or 0,484 g/100 mL haemoglobin). In marked contrast, we found no haemoglobin interference with the Direct Bilirubin 2 reagent which complied with the method validation criteria from the French Society for Biological Chemistry. The lipemia up to 2 g/L of Ivelip did not affect neither the measurement of total bilirubin for all three methods nor the measurement of conjugated bilirubin with the Diasys and Siemens reagents. However, we observed a strong interference starting at 0,5 g/L of Ivelip with the Synermed reagent. Our data suggest that both Siemens and Diasys methods allow to measure accurately total and conjugated bilirubin in hemolytic and lipemic samples, nevertheless, the Siemens methodology is less affected by these interferences.

  5. Association between Refractive Errors and Ocular Biometry in Iranian Adults

    PubMed Central

    Hashemi, Hassan; Khabazkhoob, Mehdi; Emamian, Mohammad Hassan; Shariati, Mohammad; Miraftab, Mohammad; Yekta, Abbasali; Ostadimoghaddam, Hadi; Fotouhi, Akbar

    2015-01-01

    Purpose: To investigate the association between ocular biometrics such as axial length (AL), anterior chamber depth (ACD), lens thickness (LT), vitreous chamber depth (VCD) and corneal power (CP) with different refractive errors. Methods: In a cross-sectional study on the 40 to 64-year-old population of Shahroud, random cluster sampling was performed. Ocular biometrics were measured using the Allegro Biograph (WaveLight AG, Erlangen, Germany) for all participants. Refractive errors were determined using cycloplegic refraction. Results: In the first model, the strongest correlations were found between spherical equivalent with axial length and corneal power. Spherical equivalent was strongly correlated with axial length in high myopic and high hyperopic cases, and with corneal power in high hyperopic cases; 69.5% of variability in spherical equivalent was attributed to changes in these variables. In the second model, the correlations between vitreous chamber depth and corneal power with spherical equivalent were stronger in myopes than hyperopes, while the correlations between lens thickness and anterior chamber depth with spherical equivalent were stronger in hyperopic cases than myopic ones. In the third model, anterior chamber depth + lens thickness correlated with spherical equivalent only in moderate and severe cases of hyperopia, and this index was not correlated with spherical equivalent in moderate to severe myopia. Conclusion: In individuals aged 40-64 years, corneal power and axial length make the greatest contribution to spherical equivalent in high hyperopia and high myopia. Anterior segment biometric components have a more important role in hyperopia than myopia. PMID:26730304

  6. Laser in situ keratomileusis enhancements with the Ziemer FEMTO LDV femtosecond laser following previous LASIK treatments.

    PubMed

    Pietilä, Juhani; Huhtala, Anne; Mäkinen, Petri; Uusitalo, Hannu

    2013-02-01

    The aim of this paper is to present the accuracy, predictability, and safety outcomes of LASIK enhancements performed with the FEMTO LDV femtosecond laser (Ziemer Ophthalmic Systems, Port, Switzerland) and the Allegretto Wave Concerto 500 Hz excimer laser (Wavelight AG, Erlangen, Germany), following previous LASIK treatments. FEMTO LDV was used for flap creation in 85 previously LASIK-treated eyes of 62 patients. The intended flap thickness was 90 μm in 81 eyes and 140 μm in 4 eyes. The size of the suction ring was 9.0 mm in 72 eyes and 9.5 mm in 13 eyes. Flap dimensions were measured and correlated to preoperative characteristics. With the intended flap thickness of 90 μm in previously LASIK-treated eyes, the actual flap thickness was 90.2 ± 6.6 μm (range 80-122), and the flap diameter was 9.2 ± 0.2 mm (range 8.7-9.9). The mean hinge length was 4.0 ± 0.2 mm (range 3.0-4.8). Flap thickness correlated positively with patient age and hinge length. Complications were reported in 12 eyes (14.1 %). Most of the complications were very mild, and none of them prevented further refractive laser treatment. One eye lost two Snellen lines of best spectacle-corrected visual acuity. Femtosecond LASIK enhancement is warranted only in rare cases. Surgical experience is needed and special caution must be practiced. For cases of a primary free cap, femtosecond LASIK is not recommended.

  7. Influence of spatial and temporal spot distribution on the ocular surface quality and maximum ablation depth after photoablation with a 1050 Hz excimer laser system.

    PubMed

    Mrochen, Michael; Schelling, Urs; Wuellner, Christian; Donitzky, Christof

    2009-02-01

    To investigate the effect of temporal and spatial distributions of laser spots (scan sequences) on the corneal surface quality after ablation and the maximum ablation of a given refractive correction after photoablation with a high-repetition-rate scanning-spot laser. IROC AG, Zurich, Switzerland, and WaveLight AG, Erlangen, Germany. Bovine corneas and poly(methyl methacrylate) (PMMA) plates were photoablated using a 1050 Hz excimer laser prototype for corneal laser surgery. Four temporal and spatial spot distributions (scan sequences) with different temporal overlapping factors were created for 3 myopic, 3 hyperopic, and 3 phototherapeutic keratectomy ablation profiles. Surface quality and maximum ablation depth were measured using a surface profiling system. The surface quality factor increased (rough surfaces) as the amount of temporal overlapping in the scan sequence and the amount of correction increased. The rise in surface quality factor was less for bovine corneas than for PMMA. The scan sequence might cause systematic substructures at the surface of the ablated material depending on the overlapping factor. The maximum ablation varied within the scan sequence. The temporal and spatial distribution of the laser spots (scan sequence) during a corneal laser procedure affected the surface quality and maximum ablation depth of the ablation profile. Corneal laser surgery could theoretically benefit from smaller spot sizes and higher repetition rates. The temporal and spatial spot distributions are relevant to achieving these aims.

  8. Predicting birth weight with conditionally linear transformation models.

    PubMed

    Möst, Lisa; Schmid, Matthias; Faschingbauer, Florian; Hothorn, Torsten

    2016-12-01

    Low and high birth weight (BW) are important risk factors for neonatal morbidity and mortality. Gynecologists must therefore accurately predict BW before delivery. Most prediction formulas for BW are based on prenatal ultrasound measurements carried out within one week prior to birth. Although successfully used in clinical practice, these formulas focus on point predictions of BW but do not systematically quantify uncertainty of the predictions, i.e. they result in estimates of the conditional mean of BW but do not deliver prediction intervals. To overcome this problem, we introduce conditionally linear transformation models (CLTMs) to predict BW. Instead of focusing only on the conditional mean, CLTMs model the whole conditional distribution function of BW given prenatal ultrasound parameters. Consequently, the CLTM approach delivers both point predictions of BW and fetus-specific prediction intervals. Prediction intervals constitute an easy-to-interpret measure of prediction accuracy and allow identification of fetuses subject to high prediction uncertainty. Using a data set of 8712 deliveries at the Perinatal Centre at the University Clinic Erlangen (Germany), we analyzed variants of CLTMs and compared them to standard linear regression estimation techniques used in the past and to quantile regression approaches. The best-performing CLTM variant was competitive with quantile regression and linear regression approaches in terms of conditional coverage and average length of the prediction intervals. We propose that CLTMs be used because they are able to account for possible heteroscedasticity, kurtosis, and skewness of the distribution of BWs. © The Author(s) 2014.

  9. A Model for Evaluating Tactually Assistive Devices.

    ERIC Educational Resources Information Center

    Terrio, Lee; Haas, William

    1986-01-01

    Audiometric instruments and techniques adopted to measure tactual cueing characteristics of the Radioear B70A and the Siemens Fonator electromechanical vibrators were used by young adults. The Siemens Phonator demonstrated a wider suprathreshold operating range than did the Radioear B70A. (Author/CL)

  10. 78 FR 25304 - Siemens Medical Solutions, USA, Inc., Oncology Care Systems (Radiation Oncology), Including On...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-30

    ..., USA, Inc., Oncology Care Systems (Radiation Oncology), Including On-Site Leased Workers From Source... Medical Solutions, USA, Inc., Oncology Care Systems (Radiation Oncology), including on- site leased... of February 2013, Siemens Medical Solutions, USA, Inc., Oncology Care Systems (Radiation Oncology...

  11. UNCF, Thurgood Marshall Collaboration Encourages Teaching Careers in Math, Science

    ERIC Educational Resources Information Center

    Black Issues in Higher Education, 2005

    2005-01-01

    The Thurgood Marshall Scholarship Fund, the United Negro College Fund, and the Siemens Foundation have collaborated to establish the Siemens Teacher Scholarships, aimed at encouraging minority students to pursue teaching careers in math and science. This brief article discusses the details of the new program.

  12. Evaluation of bone density in the mandibles of young Australian adults of Mongoloid and Caucasoid descent.

    PubMed

    Ong, R G; Stevenson, M R

    1999-01-01

    To evaluate the bone density in the mandibles of young Australian adults of Mongoloid and Caucasoid descent. A panoramic radiograph (Orthophos C, Siemens AG, Bensheim, Germany) was obtained of 79 dental students from the School of Oral Health Sciences, The University of Western Australia. Exposure factors were varied for males and females. The films were automatically processed in a single batch and the optical density measured blindly at two locations by two examiners. The optical density was compared by race and sex to detect bone density differences. Individual lifestyle habits (exercise, alcohol consumption, smoking and diet) was recorded in a self-administered questionnaire. Multiple regression analysis was used to analyse the effects of physical, environmental and medical characteristics. The Mongoloid subjects were found to have approximately 20% higher bone density at the angle of mandible than Caucasoid subjects (P = 0.0094 for males, P = 0.0004 for females). Race is the most important variable associated with bone density. Mongoloid subjects should be given a higher exposure for panoramic radiography than that normally used for Caucasoid subjects.

  13. Projets et développemepts en cryoélectrotechnique

    NASA Astrophysics Data System (ADS)

    Tixador, P.; Laumond, Y.

    1991-02-01

    The use of superconductivity in electrical engineering is reviewed. It deals with low T_c superconductors as only applications under development are considered. The article describes first the " classical " uses under constant or slow varying magnetic field: coils for Superconducting Magnetic Energy Storage, they are expected as a power system stabilizer and not only as a energy storage system. The present status of superconducting field a.c. generators is reviewed and the different programs over the world are described: in Germany (KWU/Siemens), in UDSSR, and in Japan where the program Super GM is led by the Engineering Research Association for Superconductive Generation Equipment and Materials. After a description of ultra-fine multifilamentary wires for 50-60 Hz use their applications are reviewed: electrical machines, above all fully superconducting a.c. generators, transformers and limiters based on the superconducting-normal transition above the critical current. Les diverses applications de la supraconductivité en électrotechnique ou courants forts sont passées en revue. Comme il s'agit de développements en cours, seule la supraconductivité à basse température est considérée. Les applications " classiques " des supraconducteurs sont abordées en premier. Ce sont les bobines de stockage (S.M.E.S.), qui peuvent fonctionner également en régulateur, les alternateurs à inducteur supraconducteur (SC) avec les programmes japonais (super GM), allemand (KWU Siemens) et soviétique, sans oublier la lévitation magnétique... Ensuite, après un bref rappel sur les multifilamentaires ultrafins utilisables aux fréquences industrielles apparus en 1983, l'article considère les applications de ces nouveaux conducteurs SC : machines électriques avec les alternateurs entièrement supraconducteurs surtout, transformateurs et enfin limiteurs qui utilisent le phénomène original de la transition supra/normal pour limiter les surintensités.

  14. Siemens Foundation and the STEM Challenge

    ERIC Educational Resources Information Center

    Harper-Taylor, Jeniffer

    2010-01-01

    For more than 12 years, the Siemens Foundation has found unique ways to partner with organizations to support educational initiatives in science, technology, engineering and mathematics (STEM) in the United States. Its focus is clear--to educate the next generation of innovators by supporting math and science education from grade school to grad…

  15. [Patient's Experience with Living Donation: A Questionnaire-Based Survey of 144 Living Kidney Donors].

    PubMed

    Schieber, Katharina; Gaag, Sonja; Heller, Katharina; Erim, Yesim

    2018-05-01

    Living organ donation becomes more and more important as the number of patients needing organ transplantation is increasing. The University Hospital of Erlangen initiated a survey of living kidney donors to improve the process of living donation. The survey aimed to assess the donor's needs and experiences during the process of living kidney donation. From 2003 to 2014 n=199 living kidney donations were registered at the University Hospital of Erlangen. A total of n=144 living kidney donors (65.3% females, mean age M=58.7 years) participated in the study. In general, the majority of the living kidney donors were satisfied with the process of donation. Almost all of them (98%) confirmed to donate again, if it was possible. A large part of the living kidney donors denied any negative physical or psychological consequences of the donation. However, around 25% reported still physical problems for example wound healing, pain or long-term hypertension. Furthermore, a lack of pre- and post-operative psychological care or a regular medical follow-up care was reported. Thus, clinical practice needs to be further developed to meet the patient's needs. © Georg Thieme Verlag KG Stuttgart · New York.

  16. ETV Report:Siemens Model H-4XE-HO Open Channel UV System

    EPA Science Inventory

    Verification testing of the Siemens Barrier Sunligt H-4XE-HO UV System was completed at the UV Validation and Research Center of New York (UV Center), located in Johnstown, NY. The H-4XE System utilizes 16 high-output, low-pressure lamps oriented horizontally and parallel to the...

  17. Europe/Latin America Report Science and Technology.

    DTIC Science & Technology

    1997-01-15

    Partners: Mr. W. Horak Siemens A.G. KO AP 313 Otto Hahn Ring 6 D-8000München 83 Tel: 49-89-72223728 Tlx: 521090 Fax: 49-89-63647140 Siemens A.G...operate the equipment, Dr Joao Renato Pinho of the Adolfo Lutz Institute is pursuing studies in molecular hybridization at the University of Lyons, in

  18. Development of a measurement and control system for a 10 kW@20 K refrigerator based on Siemens PLC S7-300

    NASA Astrophysics Data System (ADS)

    Li, J.; Liu, L. Q.; Liu, T.; Xu, X. D.; Dong, B.; Lu, W. H.; Pan, W.; Wu, J. H.; Xiong, L. Y.

    2017-02-01

    A 10 kW@20 K refrigerator has been established by the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. A measurement and control system based on Siemens PLC S7-300 for this 10 kW@20 K refrigerator is developed. According to the detailed measurement requirements, proper sensors and transmitters are adopted. Siemens S7-300 PLC CPU315-2 PN/DP operates as a master station. Two sets of ET200M DP remote expand I/O, one power meter, two compressors and one vacuum gauge operate as slave stations. Profibus-DP field communication and Modbus communication are used between the master station and the slave stations in this control system. The upper computer HMI (Human Machine Interface) is compiled using Siemens configuration software WinCC V7.0. The upper computer communicates with PLC by means of industrial Ethernet. After commissioning, this refrigerator has been operating with a 10 kW of cooling power at 20 K for more than 72 hours.

  19. Comparison of estimates of left ventricular ejection fraction obtained from gated blood pool imaging, different software packages and cameras.

    PubMed

    Steyn, Rachelle; Boniaszczuk, John; Geldenhuys, Theodore

    2014-01-01

    To determine how two software packages, supplied by Siemens and Hermes, for processing gated blood pool (GBP) studies should be used in our department and whether the use of different cameras for the acquisition of raw data influences the results. The study had two components. For the first component, 200 studies were acquired on a General Electric (GE) camera and processed three times by three operators using the Siemens and Hermes software packages. For the second part, 200 studies were acquired on two different cameras (GE and Siemens). The matched pairs of raw data were processed by one operator using the Siemens and Hermes software packages. The Siemens method consistently gave estimates that were 4.3% higher than the Hermes method (p < 0.001). The differences were not associated with any particular level of left ventricular ejection fraction (LVEF). There was no difference in the estimates of LVEF obtained by the three operators (p = 0.1794). The reproducibility of estimates was good. In 95% of patients, using the Siemens method, the SD of the three estimates of LVEF by operator 1 was ≤ 1.7, operator 2 was ≤ 2.1 and operator 3 was ≤ 1.3. The corresponding values for the Hermes method were ≤ 2.5, ≤ 2.0 and ≤ 2.1. There was no difference in the results of matched pairs of data acquired on different cameras (p = 0.4933) CONCLUSION: Software packages for processing GBP studies are not interchangeable. The report should include the name and version of the software package used. Wherever possible, the same package should be used for serial studies. If this is not possible, the report should include the limits of agreement of the different packages. Data acquisition on different cameras did not influence the results.

  20. Photon Counting Computed Tomography With Dedicated Sharp Convolution Kernels: Tapping the Potential of a New Technology for Stent Imaging.

    PubMed

    von Spiczak, Jochen; Mannil, Manoj; Peters, Benjamin; Hickethier, Tilman; Baer, Matthias; Henning, André; Schmidt, Bernhard; Flohr, Thomas; Manka, Robert; Maintz, David; Alkadhi, Hatem

    2018-05-23

    The aims of this study were to assess the value of a dedicated sharp convolution kernel for photon counting detector (PCD) computed tomography (CT) for coronary stent imaging and to evaluate to which extent iterative reconstructions can compensate for potential increases in image noise. For this in vitro study, a phantom simulating coronary artery stenting was prepared. Eighteen different coronary stents were expanded in plastic tubes of 3 mm diameter. Tubes were filled with diluted contrast agent, sealed, and immersed in oil calibrated to an attenuation of -100 HU simulating epicardial fat. The phantom was scanned in a modified second generation 128-slice dual-source CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Erlangen, Germany) equipped with both a conventional energy integrating detector and PCD. Image data were acquired using the PCD part of the scanner with 48 × 0.25 mm slices, a tube voltage of 100 kVp, and tube current-time product of 100 mAs. Images were reconstructed using a conventional convolution kernel for stent imaging with filtered back-projection (B46) and with sinogram-affirmed iterative reconstruction (SAFIRE) at level 3 (I463). For comparison, a dedicated sharp convolution kernel with filtered back-projection (D70) and SAFIRE level 3 (Q703) and level 5 (Q705) was used. The D70 and Q70 kernels were specifically designed for coronary stent imaging with PCD CT by optimizing the image modulation transfer function and the separation of contrast edges. Two independent, blinded readers evaluated subjective image quality (Likert scale 0-3, where 3 = excellent), in-stent diameter difference, in-stent attenuation difference, mathematically defined image sharpness, and noise of each reconstruction. Interreader reliability was calculated using Goodman and Kruskal's γ and intraclass correlation coefficients (ICCs). Differences in image quality were evaluated using a Wilcoxon signed-rank test. Differences in in-stent diameter difference, in-stent attenuation difference, image sharpness, and image noise were tested using a paired-sample t test corrected for multiple comparisons. Interreader and intrareader reliability were excellent (γ = 0.953, ICCs = 0.891-0.999, and γ = 0.996, ICCs = 0.918-0.999, respectively). Reconstructions using the dedicated sharp convolution kernel yielded significantly better results regarding image quality (B46: 0.4 ± 0.5 vs D70: 2.9 ± 0.3; P < 0.001), in-stent diameter difference (1.5 ± 0.3 vs 1.0 ± 0.3 mm; P < 0.001), and image sharpness (728 ± 246 vs 2069 ± 411 CT numbers/voxel; P < 0.001). Regarding in-stent attenuation difference, no significant difference was observed between the 2 kernels (151 ± 76 vs 158 ± 92 CT numbers; P = 0.627). Noise was significantly higher in all sharp convolution kernel images but was reduced by 41% and 59% by applying SAFIRE levels 3 and 5, respectively (B46: 16 ± 1, D70: 111 ± 3, Q703: 65 ± 2, Q705: 46 ± 2 CT numbers; P < 0.001 for all comparisons). A dedicated sharp convolution kernel for PCD CT imaging of coronary stents yields superior qualitative and quantitative image characteristics compared with conventional reconstruction kernels. Resulting higher noise levels in sharp kernel PCD imaging can be partially compensated with iterative image reconstruction techniques.

  1. Building a Better Grid, in Partnership with the OMNETRIC Group and Siemens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Waight, Jim; Grover, Shailendra; Wiedetz, Clark

    In collaboration with Siemens and the National Renewable Energy Laboratory (NREL), OMNETRIC Group developed a distributed control hierarchy—based on an open field message bus (OpenFMB) framework—that allows control decisions to be made at the edge of the grid. The technology was validated and demonstrated at NREL’s Energy Systems Integration Facility.

  2. 77 FR 36003 - Notice of Lodging of Consent Decree Under the Clean Water Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-15

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Water Act Notice is hereby given that on June 11, 2012, a proposed Consent Decree in United States v. Siemens Industry, Inc.... Siemens Industry, Inc., D.J. Ref. 90-5-1-1-09287. During the public comment period, the proposed Decree...

  3. Project GOLD: Growth Opportunities through Learning & Doing, Performance Reporting Period, November 1, 1996-February 28, 1998. National Workplace Literacy Program.

    ERIC Educational Resources Information Center

    Seminole Community Coll., Sanford, FL.

    Project "Growth Opportunities through Learning and Doing" (GOLD), Seminole Community College's basic skills update program, enrolled 107 students at 2 manufacturing facilities from April 1995-February 1998. Employees from Siemens Telecom Network (formerly known as Siemens Stromberg-Carlson) studied offsite in a classroom equipped with 10 computers…

  4. JPRS Report, Science & Technology, Europe & Latin America, Argentina: Specifications of ARGOS 380 MW Reactor.

    DTIC Science & Technology

    1988-02-18

    programme. It has a licensing agreement with Siemens AG’s Kraftwerk Union AG, which is its minor shareholder. Under this agreement, ENACE has the...Argentine nuclear programme. It has a licensing agreement with Siemens AG’s Kraftwerk Union AG, which is its minor shareholder. Under this agreement, ENACE

  5. 2.5 dimension structures in deep proton lithography

    NASA Astrophysics Data System (ADS)

    Kasztelanic, Rafal

    2006-04-01

    There are several technologies for cheap mass fabrication of microelements. One of them is deep proton lithography, used for the fabrication of elements of high structural depth. In this technology, accelerated protons are usually focused or formed by a mask to light a target. The energy of the proton beam is enough for all the protons to get through the target, losing only a part of their kinesthetic energy. Protons leaving the target are counted in various ways, thanks to which it is possible to estimate the energy deposed inside the target. In the next step chemical development is used to get rid of the radiated part of the target. With the use of this method, various 2D microelements can be obtained and the proton beam plays the role of a knife, cutting out the required shapes from the material. However, in order to make elements of modified surface (2.5D surface) it is necessary to change the energy of the proton beam or to change the dose deposed inside the material. The current article presents a proposal of creating simple 2.5D structures with the use of the method modifying the deposed does. This entails the modification of the deep proton lithography setup, which results moving the part for measuring the deposed dose of energy before the target. Additionally, the new deep proton lithography setup operates in the air. This article presents the results of simulations, as well as experimental results for such a setup built for the tandem accelerator in Erlangen, Germany.

  6. Power profiles of single vision and multifocal soft contact lenses.

    PubMed

    Wagner, Sandra; Conrad, Fabian; Bakaraju, Ravi C; Fedtke, Cathleen; Ehrmann, Klaus; Holden, Brien A

    2015-02-01

    The purpose of this study was to investigate the optical zone power profile of the most commonly prescribed soft contact lenses to assess their potential impact on peripheral refractive error and hence myopia progression. The optical power profiles of six single vision and ten multifocal contact lenses of five manufacturers in the powers -1.00 D, -3.00 D, and -6.00 D were measured using the SHSOphthalmic (Optocraft GmbH, Erlangen, Germany). Instrument repeatability was also investigated. Instrument repeatability was dependent on the distance from the optical centre, manifesting unreliable data for the central 1mm of the optic zone. Single vision contact lens measurements of -6.00 D lenses revealed omafilcon A having the most negative spherical aberration, lotrafilcon A having the least. Somofilcon A had the highest minus power and lotrafilcon A the biggest deviation in positive direction, relative to their respective labelled powers. Negative spherical aberration occurred for almost all of the multifocal contact lenses, including the centre-distance designs etafilcon A bifocal and omafilcon A multifocal. Lotrafilcon B and balafilcon A seem to rely predominantly on the spherical aberration component to provide multifocality. Power profiles of single vision soft contact lenses varied greatly, many having a negative spherical aberration profile that would exacerbate myopia. Some lens types and powers are affected by large intra-batch variability or power offsets of more than 0.25 dioptres. Evaluation of power profiles of multifocal lenses was derived that provides helpful information for prescribing lenses for presbyopes and progressing myopes. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  7. Safety, efficacy, predictability and stability of laser in situ keratomileusis (LASIK) with a 1000-Hz scanning spot excimer laser.

    PubMed

    Khoramnia, Ramin; Salgado, Josefina P; Wuellner, Christian; Donitzky, Christof; Lohmann, Chris P; Winkler von Mohrenfels, Christoph

    2012-09-01

    To evaluate the safety, efficacy, predictability and stability of laser in situ keratomileusis (LASIK) with a 1000-Hz scanning spot excimer laser (Concept System 1000; WaveLight GmbH, Erlangen, Germany). LASIK was performed on twenty eyes with myopia or myopic astigmatism (mean spherical equivalent refraction: -3.97±1.72 dioptres (D); mean cylinder: -0.84±0.77 D) using a microkeratome for flap creation and the Concept System 1000 for photoablation. Patients were examined preoperatively as well as 1, 3 and 6 months after the treatment. Manifest sphere and cylinder, uncorrected (UCDVA) and best corrected (BCDVA) distance visual acuity, corneal topography and pachymetry were analysed. We observed no adverse events that might have been associated with the use of a repetition rate of 1000 Hz. All eyes maintained or had improved BCDVA at 6 months after treatment when compared to preoperative values. Six months after LASIK, UCDVA was 20/20 or better in 85% and 20/25 or better in 100% of the eyes. The spherical equivalent refraction was within ±0.50 D in 95% of the eyes at 6 months after surgery. The refraction stayed stable over time; 95% of the eyes changed<0.5 D postoperatively. LASIK with the prototype 1000-Hz excimer laser was safe, efficient and predictable. The postoperative refraction was stable over time. There were no specific clinical side-effects that might be associated with the use of such a high repetition rate. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  8. Optical clearing of the eye using the See Deep Brain technique.

    PubMed

    Hohberger, B; Baumgart, C; Bergua, A

    2017-10-01

    PurposeTissue clearing has been used in anatomy for the first time in Germany over a century ago. Neuronal tissue, like cortex, was investigated in mice using a water-based optical clearing method termed See Deep Brain (SeeDB). However, although the eye belongs to the central nervous system, this histological technique was not applied in the eye up to date. We applied SeeDB for the visualization of intraocular structures.Patients and methodsFour eyes of cornea donors (two male, two female: 73-84 years) obtained from the Cornea Bank of the Department of Ophthalmology Erlangen, four chicken eyes and two mices' optic nerve were used. Bulbi were fixed in 4% paraformaldehyde in phosphate-buffered saline and treated with increasing concentrations of aqueous fructose solution with 0.5% α-thioglycerol. After SeeDB, transscleral macrophotographs of the choroid were performed.ResultsComplete transparency of the sclera was obtained in enucleated human and chicken eyes after SeeDB treatment. Macroscopical anatomy of the choroid (partially transparent due to the remaining retinal pigment epithelium and melanocytes) showing vessels and other related structures was possible without preparing slides. Mice optic nerves were also transparent after SeeDB treatment.ConclusionThe SeeDB method allows visualization of intraocular structures through a completely translucent sclera. This innovative processing technique could facilitate comprehensive qualitative and quantitative topographical anatomical studies of human and animal eyes, preserving their 3D architecture. Supra- and intrachoroidal ganglionic plexus could potentially be visualized transsclerally. Finally, clinical-pathological correlations of intraocular diseases-for example, retinal tumors-will be possible in non-dissected eyes.

  9. PREFACE: International Conference on Magnetism (ICM 2009)

    NASA Astrophysics Data System (ADS)

    Goll, Gernot; Löhneysen, Hilbert v.; Loidl, Alois; Pruschke, Thomas; Richter, Manuel; Schultz, Ludwig; Sürgers, Christoph; Wosnitza, Jochen

    2010-11-01

    The International Conference on Magnetism 2009 (ICM 2009) was held in Karlsruhe, Germany, from 26-31 July 2009. Previous conferences in this series were organized in Edingburgh, United Kingdom (1991), Warsaw, Poland (1994), Cairns, Australia (1997), Recife, Brazil (2000), Rome, Italy (2003) and Kyoto, Japan (2006). As with previous ICM conferences, the annual Conference on Strongly Correlated Electron Systems (SCES) was integrated into ICM 2009. Conference photograph Participants of ICM 2009 in front of the Stadthalle Karlsruhe. Topics of ICM 2009 were: Strongly Correlated Electron Systems; Quantum and Classical Spin Systems; Magnetic Structures and Interactions; Magnetization Dynamics and Micromagnetics; Spin-Dependent Transport; Spin Electronics; Magnetic Thin Films, Particles, and Nanostructures; Soft and Hard Magnetic Materials and their Applications; Novel Materials and Device Applications; Magnetic Recording and Memories; Measuring Techniques and Instrumentation, as well as Interdisciplinary Topics. We are grateful to the International Advisory Committee for their help in putting up an attractive program encompassing practically all aspects of magnetism, both experimentally and theoretically. The program committee comprised A Loidl, Germany (Chair), M A Continentino, Brazil, D E Dahlberg, USA, D Givord, France, G Güntherodt, Germany, H Mikeska, Germany, D Kaczorowski, Poland, Ching-Ray Chang, South Korea, I Mertig, Germany, D Vollhardt, Germany and E F Wassermann, Germany was also head of the National Organizing Committee. His help is gratefully acknowledged. Photographs Left: Poster session in the Stadthalle Karlsruhe. Upper right: H v Löhneysen (Conference Chairman), Nobel Laureates A Fert and P. Grünberg, E Umbach (Chairman of the Executive Board of Forschungszentrum Karlsruhe) (left to right). Lower right: Nobel Laureate P W Anderson. The scientific program started on Monday 27 July 2009 with opening addresses by the Conference Chairman, the deputy Mayor of Karlsruhe, Ms M Mergen, and the Chairman of the Executive Board of Forschungszentrum Karlsruhe, E Umbach. ICM 2009 was attended by the Nobel Laureates P W Anderson, A Fert and P Grünberg who gave plenary talks. A special highlight was the presentation of the Magnetism Award and Néel Medal to S S P Parkin who presented his newest results in a plenary talk as well. The IUPAP Young Scientist Award on Magnetism was given to S O Valenzuela, E Saitoh and T Kimura. The sessions were held in the Stadthalle Karlsuhe operated by the Karlsruher Messe- und Kongress-GmbH (KMK). We are grateful to Ms M Mäkelburg (KMK) for a perfect organization at the conference site. The conference was attended by 1552 participants from 48 countries, with about 50 percent from overseas (see figure). The program entailed six plenary talks (40 minutes each), with 16 half-plenary and 41 invited talks (30 minutes) and 298 contributed talks (15 minutes). Extended lunch breaks and evenings were devoted to the poster sessions, with a total of 1632 posters presented. Attendance breakdown All submitted papers were reviewed in order to meet the standards of Journal of Physics: Condensed Matter and Journal of Physics: Conference Series. The referees made every effort possible to ensure that the manuscripts submitted for publication in the proceedings reach a high standard. The tremendous work in organizing the paper classification and refereeing procedures was carried out by the Publication Committee which was headed by J Wosnitza, and comprised, in addition, Th Pruschke, M Richter and L Schultz. We also thank G Douglas, IOP Publishing, for his efficient support with the preparation of these proceedings. We gratefully acknowledge the help of L Behrens, E Maass and B Schelske in preparing the conference. The conference would not have been possible without G Goll (conference secretary) and C Sürgers (finance). I thank them for their great help. Thanks go to the many students in blue T-shirts who helped to run the conference. We are grateful for financial support to Universität Karlsruhe (TH) and Forschungszentrum Karlsruhe (both institutions merged to form the Karlsruhe Institute of Technology (KIT) as of 1 October 2009), International Union of Pure and Applied Physics (IUPAP), the City of Karlsruhe, Deutsche Forschungsgemeinschaft (German National Science Foundation) and the European Commission through COST MPNS Action P16. Hilbert v Löhneysen Karlsruhe Institute of Technology Email address: hilbert.loehneysen@kit.edu Logo Conference Organization Chairperson Hilbert v Löhneysen, Karlsruhe Members of IUPAP Commission 9 Magnetism C Chang, TaipeiD Kaczorowski, Wroclaw khrouhou, SfaxP H Kes, Leiden M A Continentino, NiteróiS Maekawa, Sendai D E Dahlberg, MinnesotaI Mertig, Halle D Fiorani, RomaD McMorow, London M R Freeman, EdmontonS Rezende, Recife D Givord, GrenobleS Sanvito, Dublin A Granovsky, MoscowJ Xiaofeng, Shanghai International Advisory Board G Aeppli, UKM Gingras, Canada I Affleck, CanadaJ C Gomez Sal, Spain J Akimitsu, JapanP A Grünberg, Germany D Awschalom, USAB Heinrich, Canada S D Bader, USAT J Hicks, Australia E Baggio-Saitovitch, BrazilM R Ibarra, Spain M N Baibich, BrazilY H Jeong, Korea G Baskaran, IndiaB Keimer, Germany E Bauer, AustriaG Kotliar, USA R J Birgeneau, USAR B Laughlin, USA P Bruno, GermanyP A Lee, USA J Chapman, UKG G Lonzarich, UK Y Endoh, JapanA MacDonald, USA A Fert, FranceM B Maple, USA J Fink, GermanyA J Millis, USA Z Fisk, USAL W Molenkamp, Germany J Flouquet, FranceJ A Mydosh, Germany A J Freeman, USAY Maeno, Japan H Fukuyama, JapanK Miyake, Japan P Fulde, GermanyP Nordblad, Sweden H Ohno, JapanF Steglich, Germany H R Ott, SwitzerlandT Takabatake, Japan Y Onuki, JapanJ L Tholence, France S S P Parkin, USAY Tokura, Japan A P Ramirez, USAK Ueda, Japan T M Rice, SwitzerlandD Vollhardt, Germany Z X Shen, USAE F Wassermann, Germany S -C Shin, KoreaM K Wu, Taiwan T Shinjo, JapanD Y Xing, China J C Slonczewski, USAY D Yao, Taiwan H Szymczak, PolandF C Zhang, Hong Kong National Organizing Committee E F Wassermann (Chair), DuisburgB Keimer, Stuttgart G Bayreuther, RegensburgJ Litterst, Braunschweig T Brückel, JülichI Mertig, Halle B Büchner, DresdenG Reiss, Bielefeld R Claessen, WürzburgK Samwer, Göttingen M Farle, DuisburgL Schultz, Dresden M Fähnle, StuttgartF Steglich, Dresden G Güntherodt, AachenD Vollhardt, Augsburg P Grünberg, JülichJ Wecker, Erlangen W Hanke, WürzburgD Weiss, Regensburg B Hillebrands, KaiserslauternR Wiesendanger, Hamburg R Hilzinger, HanauJ Wosnitza, Dresden A Loidl, AugsburgP Wöle, Karlsruhe A Kasten, RheinstettenH Zabel, Bochum Program Committee A Loidl, Germany (Chair)D Kaczorowski, Poland Ching-Ray Chang, TaiwanI Mertig, Germany M A Continentino, BrazilH Mikeska, Germany D E Dahlberg, USAD Vollhardt, Germany D Givord, FranceE F Wassermann, Germany G Güntherodt, Germany

  10. Influence of cardiac motion on stent lumen visualization in third generation dual-source CT employing a pulsatile heart model.

    PubMed

    Petri, Nils; Gassenmaier, Tobias; Allmendinger, Thomas; Flohr, Thomas; Voelker, Wolfram; Bley, Thorsten A

    2017-02-01

    To detect an in-stent restenosis, an invasive coronary angiography is commonly performed. Owing to the risk associated with this procedure, a non-invasive method to detect or exclude an in-stent restenosis is desirable. The purpose of this study was to evaluate the influence of cardiac motion on stent lumen visibility in a third-generation dual-source CT scanner (SOMATOM Force; Siemens Healthcare, Forchheim, Germany), employing a pulsatile heart model (CoroSim ® ; Mecora, Aachen, Germany). 13 coronary stents with a diameter of 3.0 mm were implanted in plastic tubes filled with a contrast medium and then fixed onto the pulsatile phantom heart model. The scans were performed while the heart model mimicked the heartbeat. Coronary stents were scanned in an orientation parallel to the scanner z-axis. The evaluation of the stents was performed by employing a medium sharp convolution kernel optimized for vascular imaging. The mean visible stent lumen was reduced from 65.6 ± 5.7% for the stents at rest to 60.8 ± 4.4% for the stents in motion (p-value: <0.001). While the difference in lumen visibility between stents in motion and at rest was significant, the use of this third-generation dual-source CT scanner enabled a high stent lumen visibility under the influence of cardiac motion. Whether this translates into a clinical setting has to be evaluated in further patient studies. Advances in knowledge: The employed modern CT scanner enables a high stent lumen visibility even under the influence of cardiac motion, which is important to detect or exclude an in-stent restenosis.

  11. 77 FR 34935 - Foreign-Trade Zone 161; Temporary/Interim Manufacturing Authority; Siemens Energy, Inc., (Wind...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-12

    ... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [Docket T-4-2012] Foreign-Trade Zone 161; Temporary/Interim Manufacturing Authority; Siemens Energy, Inc., (Wind Turbine Nacelles and Hubs); Notice of Approval On April 2, 2012, the Executive Secretary of the Foreign-Trade Zones (FTZ) Board filed an application submitted by the Board of County...

  12. Sinusoidal Siemens star spatial frequency response measurement errors due to misidentified target centers

    DOE PAGES

    Birch, Gabriel Carisle; Griffin, John Clark

    2015-07-23

    Numerous methods are available to measure the spatial frequency response (SFR) of an optical system. A recent change to the ISO 12233 photography resolution standard includes a sinusoidal Siemens star test target. We take the sinusoidal Siemens star proposed by the ISO 12233 standard, measure system SFR, and perform an analysis of errors induced by incorrectly identifying the center of a test target. We show a closed-form solution for the radial profile intensity measurement given an incorrectly determined center and describe how this error reduces the measured SFR of the system. As a result, using the closed-form solution, we proposemore » a two-step process by which test target centers are corrected and the measured SFR is restored to the nominal, correctly centered values.« less

  13. OVERVIEW, PRACTICAL TIPS AND POTENTIAL PITFALLS OF USING AUTOMATIC EXPOSURE CONTROL IN CT: SIEMENS CARE DOSE 4D.

    PubMed

    Söderberg, Marcus

    2016-06-01

    Today, computed tomography (CT) systems routinely use automatic exposure control (AEC), which modulates the tube current. However, for optimal use, there are several aspects of an AEC system that need to be considered. The purpose of this study was to provide an overview of the Siemens CARE Dose 4D AEC system, discuss practical tips and demonstrate potential pitfalls. Two adult anthropomorphic phantoms were examined using two different Siemens CT systems. When optimising the CT radiation dose and image quality, the projection angle of the localiser, patient centring, protocol selection, scanning direction and the use of protective devices requires special attention. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. The learning type makes the difference - the interrelation of Kolb's learning styles and psychological status of preclinical medical students at the University of Erlangen.

    PubMed

    Burger, Pascal H; Scholz, Michael

    2014-01-01

    Theories on learning styles and types have been integral to discussions on the basics of teaching for nearly 40 years. The learning style typology of Kolb divides learners into four groups (Diverger, Assimilator, Converger and Accomodator), which differ both in terms of their learning behaviour as well as personality and preferences. We studied the sense of coherence and burnout symptoms in medical students of the preclinical semesters (1(st) to 4(th) semester) at the Friedrich-Alexander University of Erlangen within the context of the observed learning styles. A total of 530 students were interviewed in winter semester 2012/13 using standardized psychometric questionnaires. Our students showed a significant correlation between the respective learning styles and expression of a sense of coherence, as well as cognitive and emotional burnout symptoms. The learning styles of the students differed significantly within these same parameters. We also demonstrated that learning styles and types not only influence study performance, but that there are also relationships to sense of coherence and psychological ailments. A more forward-looking integration of the theory of learning types in the medical education curriculum could positively influence both the performance and psychological well-being of the students.

  15. The learning type makes the difference – the interrelation of Kolb's learning styles and psychological status of preclinical medical students at the University of Erlangen

    PubMed Central

    Burger, Pascal H.; Scholz, Michael

    2014-01-01

    Theories on learning styles and types have been integral to discussions on the basics of teaching for nearly 40 years. The learning style typology of Kolb divides learners into four groups (Diverger, Assimilator, Converger and Accomodator), which differ both in terms of their learning behaviour as well as personality and preferences. We studied the sense of coherence and burnout symptoms in medical students of the preclinical semesters (1st to 4th semester) at the Friedrich-Alexander University of Erlangen within the context of the observed learning styles. A total of 530 students were interviewed in winter semester 2012/13 using standardized psychometric questionnaires. Our students showed a significant correlation between the respective learning styles and expression of a sense of coherence, as well as cognitive and emotional burnout symptoms. The learning styles of the students differed significantly within these same parameters. We also demonstrated that learning styles and types not only influence study performance, but that there are also relationships to sense of coherence and psychological ailments. A more forward-looking integration of the theory of learning types in the medical education curriculum could positively influence both the performance and psychological well-being of the students. PMID:25489342

  16. Impact of light exposure on thyroid-stimulating hormone results using the Siemens Advia Centaur TSH-3Ultra assay.

    PubMed

    Armer, Jane; Giles, Diane; Lancaster, Ian; Brownbill, Kathryn

    2017-09-01

    Background Thyroid-stimulating hormone (TSH) is used as the first-line test of thyroid function. Siemens Healthcare Diagnostics recommend that Siemens Centaur reagents must be protected from light in the assay information and on reagent packaging. We have compared the effect of light exposure on results using Siemens TSH-3Ultra and follicle-stimulating hormone reagents. The thyroid-stimulating hormone reagent includes fluoroscein thiocyanate whereas the follicle-stimulating hormone reagent does not. Methods Three levels of quality controls were analysed using SiemensTSH-3Ultra and follicle-stimulating hormone reagent packs that had been kept protected from light or exposed to light at 6-h intervals for 48 h and then at 96 h. Results Thyroid-stimulating hormone results were significantly lower after exposure of TSH-3Ultra reagent packs to light. Results were >15% lower at all three levels of quality control following 18 h of light exposure and continued to decrease until 96 h. There was no significant difference in follicle-stimulating hormone results whether reagents had been exposed to or protected from light. Conclusions Thyroid-stimulating hormone results but not follicle-stimulating hormone results are lowered after exposure of reagent packs to light. Laboratories must ensure that TSH-3Ultra reagents are not exposed to light and analyse quality control samples on every reagent pack to check that there has not been light exposure prior to delivery. The labelling on TSH-3Ultra reagent packs should reflect the significant effect of light exposure compared with the follicle-stimulating hormone reagent. We propose that the effect of light exposure on binding of fluoroscein thiocyanate to the solid phase antibody causes the falsely low results.

  17. [Development of an ophthalmological clinical information system for inpatient eye clinics].

    PubMed

    Kortüm, K U; Müller, M; Babenko, A; Kampik, A; Kreutzer, T C

    2015-12-01

    In times of increased digitalization in healthcare, departments of ophthalmology are faced with the challenge of introducing electronic clinical health records (EHR); however, specialized software for ophthalmology is not available with most major EHR sytems. The aim of this project was to create specific ophthalmological user interfaces for large inpatient eye care providers within a hospitalwide EHR. Additionally the integration of ophthalmic imaging systems, scheduling and surgical documentation should be achieved. The existing EHR i.s.h.med (Siemens, Germany) was modified using advanced business application programming (ABAP) language to create specific ophthalmological user interfaces for reproduction and moreover optimization of the clinical workflow. A user interface for documentation of ambulatory patients with eight tabs was designed. From June 2013 to October 2014 a total of 61,551 patient contact details were documented. For surgical documentation a separate user interface was set up. Digital clinical orders for documentation of registration and scheduling of operations user interfaces were also set up. A direct integration of ophthalmic imaging modalities could be established. An ophthalmologist-orientated EHR for outpatient and surgical documentation for inpatient clinics was created and successfully implemented. By incorporation of imaging procedures the foundation of future smart/big data analyses was created.

  18. Dose and image quality for a cone-beam C-arm CT system.

    PubMed

    Fahrig, Rebecca; Dixon, Robert; Payne, Thomas; Morin, Richard L; Ganguly, Arundhuti; Strobel, Norbert

    2006-12-01

    We assess dose and image quality of a state-of-the-art angiographic C-arm system (Axiom Artis dTA, Siemens Medical Solutions, Forchheim, Germany) for three-dimensional neuro-imaging at various dose levels and tube voltages and an associated measurement method. Unlike conventional CT, the beam length covers the entire phantom, hence, the concept of computed tomography dose index (CTDI) is not the metric of choice, and one can revert to conventional dosimetry methods by directly measuring the dose at various points using a small ion chamber. This method allows us to define and compute a new dose metric that is appropriate for a direct comparison with the familiar CTDIw of conventional CT. A perception study involving the CATPHAN 600 indicates that one can expect to see at least the 9 mm inset with 0.5% nominal contrast at the recommended head-scan dose (60 mGy) when using tube voltages ranging from 70 kVp to 125 kVp. When analyzing the impact of tube voltage on image quality at a fixed dose, we found that lower tube voltages gave improved low contrast detectability for small-diameter objects. The relationships between kVp, image noise, dose, and contrast perception are discussed.

  19. [Virtual bronchoscopy in the child using multi-slice CT: initial clinical experiences].

    PubMed

    Kirchner, J; Laufer, U; Jendreck, M; Kickuth, R; Schilling, E M; Liermann, D

    2000-01-01

    Virtual bronchoscopy of the pediatric patient has been reported to be more difficult because of artifacts due to breathing or motion. We demonstrate the benefit of the accelerated examination based on multislice spiral CT (MSCT) in the pediatric patient which has not been reported so far. MSCT (tube voltage 120 kV, tube current 110 mA, 4 x 1 mm Slice thickness, 500 ms rotation time, Pitch 6) was performed on a CT scanner of the latest generation (Volume Zoom, Siemens Corp. Forchheim, Germany). In totally we examined 11 patients (median age 48 months, range 2-122 months) suspected of having tracheoesophageal fistula (n = 2), tracheobronchial narrowing (n = 8) due to intrinsic or extrinsic factors or injury of the bronchial system (n = 1). In all patients we obtained sufficient data for 3D reconstruction avoiding general anesthesia. 6/11 examinations were described to be without pathological finding. A definite diagnosis was obtained in 10 patients. Virtual bronchoscopy could avoid other invasive diagnostic examination in 8/11 patients (73%). Helical CT provides 3D-reconstruction and virtual bronchoscopy in the newborn as well as the infant. It avoids additional diagnostic bronchoscopy in a high percentage of all cases.

  20. CT fluoroscopy-assisted puncture of thoracic and abdominal masses: a randomized trial.

    PubMed

    Kirchner, Johannes; Kickuth, Ralph; Laufer, Ulf; Schilling, Esther Maria; Adams, Stephan; Liermann, Dieter

    2002-03-01

    We investigated the benefit of real-time guidance of interventional punctures by means of computed tomography fluoroscopy (CTF) compared with the conventional sequential acquisition guidance. In a prospective randomized trial, 75 patients underwent either CTF-guided (group A, n = 50) or sequential CT-guided (group B, n = 25) punctures of thoracic (n = 29) or abdominal (n = 46) masses. CTF was performed on the CT machine (Somatom Plus 4 Power, Siemens Corp., Forchheim, Germany) equipped with the C.A.R.E. Vision application (tube voltage 120 kV, tube current 50 mA, rotational time 0.75 s, slice thickness 10 mm, 8 frames/s). The average procedure time showed a statistically significant difference between the two study groups (group A: 564 s, group B 795 s, P = 0.0032). The mean total mAs was 7089 mAs for the CTF and 4856 mAs for the sequential image-guided intervention, respectively. The sensitivity was 71% specificity 100% positive predictive value 100% and negative predictive value 60% for the CTF-guided puncture, and 68, 100, 100 and 50% for sequential CT, respectively. CTF guidance realizes a time-saving but increases the radiation exposure dosage.

  1. Further observations on OCOM MOX fuel: microstructure in the vicinity of the pellet rim and fuel — cladding interaction

    NASA Astrophysics Data System (ADS)

    Walker, C. T.; Goll, W.; Matsumura, T.

    1997-06-01

    The fuel investigated was manufactured by Siemens-KWU and irradiated at low rating in the KWO reactor in Germany. The MOX agglomerates in the cold outer region of the fuel shared several common features with the high burn-up structure at the rim of UO 2 fuel. It is proposed that in both cases the mechanism producing the microstructure change is recrystallisation. Further, it is shown that surface MOX agglomerates do not noticeably retard cladding creepdown although they swell into the gap. The contracting cladding appears able to push the agglomerates back into the fuel. The thickness of the oxide layer on the inner cladding surface increased at points where contact with surface MOX agglomerates had occurred. Despite this, the mean thickness of the oxide did not differ significantly from that found in UO 2 fuel rods of like design. It is judged that the high burn-up structure will form in the UO 2 matrix when the local burn-up there reaches 60 to 80 GWd/tM. Limiting the MOX scrap addition in the UO 2 matrix will delay its formation.

  2. Development of a Measurement and Control System for a 40l/h Helium Liquefier based on Siemens PLC S7-300

    NASA Astrophysics Data System (ADS)

    Li, J.; Liu, L. Q.; Xu, X. D.; Liu, T.; Li, Q.; Hu, Z. J.; Wang, B. M.; Xiong, L. Y.; Dong, B.; Yan, T.

    A 40l/h Helium Liquefier has been commissioned by the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. A measurement and control system based on Siemens PLC S7-300 for this Helium Liquefier is developed. Proper sensors are selected, for example, three types of transmitters are adopted respectively according to detailed temperature measurement requirements. Siemens S7-300 PLC CPU315-2PN/DP operates as a master station and three sets of ET200 M DP remote expand I/O operate asslave stations. Profibus-DP field communication is used between the master station and the slave stations. The upper computer HMI(Human Machine Interface) is compiled using Siemens configuration software WinCC V7.0. The upper computer communicates with PLC by means of industrial Ethernet. A specific control logic for this Helium Liquefier is developed. The control of the suction and discharge pressures of the compressor and the control of the turbo-expanders loop are being discussed in this paper. Following the commissioning phase, the outlet temperature of the second stage turbine has reached 8.6K and the temperature before the throttle valve has reached 13.1K.

  3. Measurement and control system for cryogenic helium gas bearing turbo-expander experimental platform based on Siemens PLC S7-300

    NASA Astrophysics Data System (ADS)

    Li, J.; Xiong, L. Y.; Peng, N.; Dong, B.; Wang, P.; Liu, L. Q.

    2014-01-01

    An experimental platform for cryogenic Helium gas bearing turbo-expanders is established at the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. This turbo-expander experimental platform is designed for performance testing and experimental research on Helium turbo-expanders with different sizes from the liquid hydrogen temperature to the room temperature region. A measurement and control system based on Siemens PLC S7-300 for this turbo-expander experimental platform is developed. Proper sensors are selected to measure such parameters as temperature, pressure, rotation speed and air flow rate. All the collected data to be processed are transformed and transmitted to S7-300 CPU. Siemens S7-300 series PLC CPU315-2PN/DP is as master station and two sets of ET200M DP remote expand I/O is as slave station. Profibus-DP field communication is established between master station and slave stations. The upper computer Human Machine Interface (HMI) is compiled using Siemens configuration software WinCC V6.2. The upper computer communicates with PLC by means of industrial Ethernet. Centralized monitoring and distributed control is achieved. Experimental results show that this measurement and control system has fulfilled the test requirement for the turbo-expander experimental platform.

  4. Implementation of Siemens USS protocol into LabVIEW.

    PubMed

    Hosek, P; Diblik, M

    2011-10-01

    This article gives basic overview of the USS protocol as a communication interface to drive Siemens frequency inverters. It presents our implementation of this protocol into LabVIEW, as there was permanent demand from the community of the users to have native LabVIEW implementation of the USS protocol. It also states encountered problems and their solutions. Copyright © 2011 Society for Laboratory Automation and Screening. Published by Elsevier Inc. All rights reserved.

  5. Digital SPC Switching Technology--Foreign Technology Assessment

    DTIC Science & Technology

    1990-12-01

    India C DOT MAX C DOT DSS 0 TDX 1 Samsung , Goldstar Korea TDX 10 Daewoo, Otelco (ROK) System X Plessey/GEC U.K. (Siemens) Fetex 150 Fujitsu Japan HDX...x South Korea Alcatel ATT Malaysia Ericsson NEC New Zealand NEC Philippines DAEWOO Siemens Singapore Fujitsu (AU-, NEC Gateway Switches) Taiwan...Yes Israel Northern Telecom DMS 10 Telrad Yes OMS 100 * Malaysia Ericsson AXE Pewira Ericsson Future SDN BHD Mexico Alcatel System 12 Indetel No

  6. MO-F-CAMPUS-I-02: Occupational Conceptus Doses From Fluoroscopically-Guided Interventional Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Damilakis, J; Perisinakis, K; Solomou, G

    Purpose: The aim of this method was to provide dosimetric data on conceptus dose for the pregnant employee who participates in fluoroscopically-guided interventional procedures. Methods: Scattered air-kerma dose rates were obtained for 17 fluoroscopic projections involved in interventional procedures. These projections were simulated on an anthropomorphic phantom placed on the examination table supine. The operating theater was divided into two grids relative to the long table sides. Each grid consisted of 33 cells spaced 0.50 m apart. During the simulated exposures, at each cell, scatter air-kerma rate was measured at 110 cm from the floor i.e. at the height ofmore » the waist of the pregnant worker. Air-kerma rates were divided by the dose area product (DAP) rate of each exposure to obtain normalized data. For each projection, measurements were performed for 3 kVp and 3 filtration values i.e. for 9 different x-ray spectra. All measurements were performed by using a modern C-arm angiographic system (Siemens Axiom Artis, Siemens, Germany) and a radiation meter equipped with an ionization chamber. Results: The results consist of 153 iso-dose maps, which show the spatial distribution of DAP-normalized scattered air-kerma doses at the waist level of a pregnant worker. Conceptus dose estimation is possible using air-kerma to embryo/fetal dose conversion coefficients published in a previous study (J Cardiovasc Electrophysiol, Vol. 16, pp. 1–8, July 2005). Using these maps, occupationally exposed pregnant personnel may select a working position for a certain projection that keeps abdominal dose as low as reasonably achievable. Taking into consideration the regulatory conceptus dose limit for occupational exposure, determination of the maximum workload allowed for the pregnant personnel is also possible. Conclusion: Data produced in this work allow for the anticipation of conceptus dose and the determination of the maximum workload for a pregnant worker from any fluoroscopically-guided interventional procedure. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)« less

  7. Early diagnosis of myocardial infarction using absolute and relative changes in cardiac troponin concentrations.

    PubMed

    Irfan, Affan; Reichlin, Tobias; Twerenbold, Raphael; Meister, Marc; Moehring, Berit; Wildi, Karin; Bassetti, Stefano; Zellweger, Christa; Gimenez, Maria Rubini; Hoeller, Rebeca; Murray, Karsten; Sou, Seoung Mann; Mueller, Mira; Mosimann, Tamina; Reiter, Miriam; Haaf, Philip; Ziller, Ronny; Freidank, Heike; Osswald, Stefan; Mueller, Christian

    2013-09-01

    Absolute changes in high-sensitivity cardiac troponin T (hs-cTnT) seem to have higher diagnostic accuracy in the early diagnosis of acute myocardial infarction compared with relative changes. It is unknown whether the same applies to high-sensitivity cardiac troponin I (hs-cTnI) assays and whether the combination of absolute and relative change might further increase accuracy. In a prospective, international multicenter study, high-sensitivity cardiac troponin (hs-cTn) was measured with 3 novel assays (hs-cTnT, Roche Diagnostics Corp, Indianapolis, Ind; hs-cTnI, Beckman Coulter Inc, Brea, Calif; hs-cTnI, Siemens, Munich, Germany) in a blinded fashion at presentation and after 1 and 2 hours in a blinded fashion in 830 unselected patients with suspected acute myocardial infarction. The final diagnosis was adjudicated by 2 independent cardiologists. The area under the receiver operating characteristic curve for diagnosing acute myocardial infarction was significantly higher for 1- and 2-hour absolute versus relative hs-cTn changes for all 3 assays (P < .001). The area under the receiver operating characteristic curve of the combination of 2-hour absolute and relative change (hs-cTnT 0.98 [95% confidence interval {CI}, 0.97-0.99]; hs-cTnI, Beckman Coulter Inc, 0.97 [95% CI, 0.96-0.99]; hs-cTnI, Siemens, 0.96 [95% CI, 0.93-0.99]) were high and provided some benefit compared with the use of absolute change alone for hs-cTnT, but not for the hs-cTnI assays. Reclassification analysis confirmed the superiority of absolute changes versus relative changes. Absolute changes seem to be the preferred metrics for both hs-cTnT and hs-cTnI in the early diagnosis of acute myocardial infarction. The combination of absolute and relative changes provides a small added value for hs-cTnT, but not for hs-cTnI. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms.

    PubMed

    Bieniosek, Matthew F; Lee, Brian J; Levin, Craig S

    2015-10-01

    Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial "Micro Deluxe" phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. This work shows that 3D printed phantoms can be functionally equivalent to commercially available phantoms. They are a viable option for quickly distributing and fabricating low cost, customized phantoms.

  9. The compact Erlangen Active Simulator for Interventional Endoscopy: a prospective comparison in structured team-training courses on "endoscopic hemostasis" for doctors and nurses to the "Endo-Trainer" model.

    PubMed

    Hochberger, J; Euler, K; Naegel, A; Hahn, E G; Maiss, J

    2004-09-01

    In 1997 Hochberger and Neumann presented the "Erlangen Biosimulation Model" (commercialized as the "Erlangen Endo-Trainer") at various national and international meetings. The new compactEASIE is a simplified version of the original "Biosimulation Model" (Endo-Trainer) and is specially designed for easy handling. CompactEASIE is reduced in its features, focusing exclusively on flexible endoscopy training. The acceptance of training in endoscopic hemostasis is accepted by workshop participants, as evaluated by a questionnaire on both models. Eleven structured courses on endoscopic hemostasis for doctors and nurses organized by the same endoscopists from 3/1998 to 5/1999 were evaluated using one of both models. The questionnaires were filled in by 207/291 trainees (71%). The Endo-Trainer was used in 4 (n = 103) and the compactEASIE in 7 courses (n = 104). Both simulators were equipped with identical types of specially prepared pig-organ packages consisting of esophagus, stomach and duodenum, including artificial sewn-in vessels, polyps and varices. Blood perfusion was done with a roller pump connected to the sewn-in vessels and blood surrogate. All workshops were identical concerning the course structure: a 30-min theoretical introduction on ulcer bleeding was followed by 2 h of practical training in injection techniques and hemoclip application. The second part of variceal therapy consisted of a 30-min theoretical introduction prior to 2 h of practical training on sclerotherapy, band ligation and cyanoacrylate application. Finally, a questionnaire on the trainees' pre-experience and their rating of the different workshop sections was handed out to each participant. Previous endoscopic experience was comparable in both groups. The training in both simulators was highly accepted by the trainees (compactEASIE 95% excellent and good versus EASIE (Endo-Trainer) 97%) and did not show any significant difference (P = 0.493). Even in the assessment of the single techniques, no statistical difference was observed. Furthermore, the assessments of the closeness to reality and the endoscopic environment in both simulators were identical. Both simulators (Endo-Trainer, compactEASIE) are excellent educational tools for interventional endoscopy with a high level of acceptance. The easy-to-handle, "lightweight" compactEASIE is a significant, progress tool for the future.

  10. FDG-PET and CSF biomarker accuracy in prediction of conversion to different dementias in a large multicentre MCI cohort.

    PubMed

    Caminiti, Silvia Paola; Ballarini, Tommaso; Sala, Arianna; Cerami, Chiara; Presotto, Luca; Santangelo, Roberto; Fallanca, Federico; Vanoli, Emilia Giovanna; Gianolli, Luigi; Iannaccone, Sandro; Magnani, Giuseppe; Perani, Daniela

    2018-01-01

    In this multicentre study in clinical settings, we assessed the accuracy of optimized procedures for FDG-PET brain metabolism and CSF classifications in predicting or excluding the conversion to Alzheimer's disease (AD) dementia and non-AD dementias. We included 80 MCI subjects with neurological and neuropsychological assessments, FDG-PET scan and CSF measures at entry, all with clinical follow-up. FDG-PET data were analysed with a validated voxel-based SPM method. Resulting single-subject SPM maps were classified by five imaging experts according to the disease-specific patterns, as "typical-AD", "atypical-AD" (i.e. posterior cortical atrophy, asymmetric logopenic AD variant, frontal-AD variant), "non-AD" (i.e. behavioural variant FTD, corticobasal degeneration, semantic variant FTD; dementia with Lewy bodies) or "negative" patterns. To perform the statistical analyses, the individual patterns were grouped either as "AD dementia vs. non-AD dementia (all diseases)" or as "FTD vs. non-FTD (all diseases)". Aβ42, total and phosphorylated Tau CSF-levels were classified dichotomously, and using the Erlangen Score algorithm. Multivariate logistic models tested the prognostic accuracy of FDG-PET-SPM and CSF dichotomous classifications. Accuracy of Erlangen score and Erlangen Score aided by FDG-PET SPM classification was evaluated. The multivariate logistic model identified FDG-PET "AD" SPM classification (Expβ = 19.35, 95% C.I. 4.8-77.8, p < 0.001) and CSF Aβ42 (Expβ = 6.5, 95% C.I. 1.64-25.43, p < 0.05) as the best predictors of conversion from MCI to AD dementia. The "FTD" SPM pattern significantly predicted conversion to FTD dementias at follow-up (Expβ = 14, 95% C.I. 3.1-63, p < 0.001). Overall, FDG-PET-SPM classification was the most accurate biomarker, able to correctly differentiate either the MCI subjects who converted to AD or FTD dementias, and those who remained stable or reverted to normal cognition (Expβ = 17.9, 95% C.I. 4.55-70.46, p < 0.001). Our results support the relevant role of FDG-PET-SPM classification in predicting progression to different dementia conditions in prodromal MCI phase, and in the exclusion of progression, outperforming CSF biomarkers.

  11. Soil as natural heat resource for very shallow geothermal application: laboratory and test site updates from ITER Project

    NASA Astrophysics Data System (ADS)

    Di Sipio, Eloisa; Bertermann, David

    2017-04-01

    Nowadays renewable energy resources for heating/cooling residential and tertiary buildings and agricultural greenhouses are becoming increasingly important. In this framework, a possible, natural and valid alternative for thermal energy supply is represented by soils. In fact, since 1980 soils have been studied and used also as heat reservoir in geothermal applications, acting as a heat source (in winter) or sink (in summer) coupled mainly with heat pumps. Therefore, the knowledge of soil thermal properties and of heat and mass transfer in the soils plays an important role in modeling the performance, reliability and environmental impact in the short and long term of engineering applications. However, the soil thermal behavior varies with soil physical characteristics such as soil texture and water content. The available data are often scattered and incomplete for geothermal applications, especially very shallow geothermal systems (up to 10 m depths), so it is worthy of interest a better comprehension of how the different soil typologies (i.e. sand, loamy sand...) affect and are affected by the heat transfer exchange with very shallow geothermal installations (i.e. horizontal collector systems and special forms). Taking into consideration these premises, the ITER Project (Improving Thermal Efficiency of horizontal ground heat exchangers, http://iter-geo.eu/), funded by European Union, is here presented. An overview of physical-thermal properties variations under different moisture and load conditions for different mixtures of natural material is shown, based on laboratory and field test data. The test site, located in Eltersdorf, near Erlangen (Germany), consists of 5 trenches, filled in each with a different material, where 5 helix have been installed in an horizontal way instead of the traditional vertical option.

  12. BRCA mutations and their influence on pathological complete response and prognosis in a clinical cohort of neoadjuvantly treated breast cancer patients.

    PubMed

    Wunderle, Marius; Gass, Paul; Häberle, Lothar; Flesch, Vivien M; Rauh, Claudia; Bani, Mayada R; Hack, Carolin C; Schrauder, Michael G; Jud, Sebastian M; Emons, Julius; Erber, Ramona; Ekici, Arif B; Hoyer, Juliane; Vasileiou, Georgia; Kraus, Cornelia; Reis, Andre; Hartmann, Arndt; Lux, Michael P; Beckmann, Matthias W; Fasching, Peter A; Hein, Alexander

    2018-05-03

    BRCA1/2 mutations influence the molecular characteristics and the effects of systemic treatment of breast cancer. This study investigates the impact of germline BRCA1/2 mutations on pathological complete response and prognosis in patients receiving neoadjuvant systemic chemotherapy. Breast cancer patients were tested for a BRCA1/2 mutation in clinical routine work and were treated with anthracycline-based or platinum-based neoadjuvant chemotherapy between 1997 and 2015. These patients were identified in the tumor registry of the Breast Center of the University of Erlangen (Germany). Logistic regression and Cox regression analyses were performed to investigate the associations between BRCA1/2 mutation status, pathological complete response, disease-free survival, and overall survival. Among 355 patients, 59 had a mutation in BRCA1 or in BRCA2 (16.6%), 43 in BRCA1 (12.1%), and 16 in BRCA2 (4.5%). Pathological complete response defined as "ypT0; ypN0" was observed in 54.3% of BRCA1/2 mutation carriers, but only in 22.6% of non-carriers. The adjusted odds ratio was 2.48 (95% CI 1.26-4.91) for BRCA1/2 carriers versus non-carriers. Patients who achieved a pathological complete response had better disease-free survival and overall survival rates compared with those who did not achieve a pathological complete response, regardless of BRCA1/2 mutation status. BRCA1/2 mutation status leads to better responses to neoadjuvant chemotherapy in breast cancer. Pathological complete response is the main predictor of disease-free survival and overall survival, independently of BRCA1/2 mutation status.

  13. A randomized, controlled trial of group cognitive-behavioral therapy for compulsive buying disorder: posttreatment and 6-month follow-up results.

    PubMed

    Mueller, Astrid; Mueller, Ulrike; Silbermann, Andrea; Reinecker, Hans; Bleich, Stefan; Mitchell, James E; de Zwaan, Martina

    2008-07-01

    The purpose of this study was to conduct a randomized trial comparing the efficacy of a group cognitive-behavioral therapy (CBT) intervention designed for the treatment of compulsive buying disorder to a waiting list control (WLC) group. Thirty-one patients with compulsive buying problems according to the criteria developed by McElroy et al. were assigned to receive active treatment (12 weekly sessions and 6-month follow-up) and 29 to the WLC group. The treatment was specifically aimed at interrupting and controlling the problematic buying behavior, establishing healthy purchasing patterns, restructuring maladaptive thoughts and negative feelings associated with shopping and buying, and developing healthy coping skills. Primary outcome measures were the Compulsive Buying Scale (CBS), the Yale-Brown Obsessive Compulsive Scale-Shopping Version (YBOCS-SV), and the German Compulsive Buying Scale (G-CBS). Secondary outcome measures were the Symptom Checklist-90-Revised (SCL-90-R), the Barratt Impulsiveness Scale (BIS-11), and the Saving Inventory-Revised (SI-R). The study was completed between November 2003 and May 2007 at the University Hospital of Erlangen, Bavaria, Germany. Multivariate analysis revealed significant differences between the CBT and the WLC groups on the primary outcome variables (outcome-by-time-by-group effect, Pillai's trace, F = 6.960, df = 1, p = .002). The improvement was maintained during the 6-month follow-up. The treatment did not affect other psychopathology, e.g., compulsive hoarding, impulsivity, or SCL-90-R scores. We found that lower numbers of visited group therapy sessions and higher pretreatment hoarding traits as measured with the SI-R total score were significant predictors for nonresponse. The results suggest that a disorder-specific cognitive-behavioral intervention can significantly impact compulsive buying behavior.

  14. Transcutaneous Auricular Vagus Nerve Stimulation with Concurrent Upper Limb Repetitive Task Practice for Poststroke Motor Recovery: A Pilot Study.

    PubMed

    Redgrave, Jessica N; Moore, Lucy; Oyekunle, Tosin; Ebrahim, Maryam; Falidas, Konstantinos; Snowdon, Nicola; Ali, Ali; Majid, Arshad

    2018-03-23

    Invasive vagus nerve stimulation (VNS) has the potential to enhance the effects of physiotherapy for upper limb motor recovery after stroke. Noninvasive, transcutaneous auricular branch VNS (taVNS) may have similar benefits, but this has not been evaluated in stroke recovery. We sought to determine the feasibility of taVNS delivered alongside upper limb repetitive task-specific practice after stroke and its effects on a range of outcome measures evaluating limb function. Thirteen participants at more than 3 months postischemic stroke with residual upper limb dysfunction were recruited from the community of Sheffield, United Kingdom (October-December 2016). Participants underwent 18 × 1-hour sessions over 6 weeks in which they made 30-50 repetitions of 8-10 arm movements concurrently with taVNS (NEMOS; Cerbomed, Erlangen, Germany, 25 Hz, .1-millisecond pulse width) at maximum tolerated intensity (mA). An electrocardiogram and rehabilitation outcome scores were obtained at each visit. Qualitative interviews determined the acceptability of taVNS to participants. Median time after stroke was 1.16 years, and baseline median/interquartile range upper limb Fugl-Meyer (UFM) score was 63 (54.5-99.5). Participants attended 92% of the planned treatment sessions. Three participants reported side effects, mainly fatigue, but all performed mean of more than 300 arm repetitions per session with no serious adverse events. There was a significant change in the UFM score with a mean increase per participant of 17.1 points (standard deviation 7.8). taVNS is feasible and well-tolerated alongside upper limb repetitive movements in poststroke rehabilitation. The motor improvements observed justify a phase 2 trial in patients with residual arm weakness. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  15. TU-EF-204-01: Accurate Prediction of CT Tube Current Modulation: Estimating Tube Current Modulation Schemes for Voxelized Patient Models Used in Monte Carlo Simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMillan, K; Bostani, M; McNitt-Gray, M

    2015-06-15

    Purpose: Most patient models used in Monte Carlo-based estimates of CT dose, including computational phantoms, do not have tube current modulation (TCM) data associated with them. While not a problem for fixed tube current simulations, this is a limitation when modeling the effects of TCM. Therefore, the purpose of this work was to develop and validate methods to estimate TCM schemes for any voxelized patient model. Methods: For 10 patients who received clinically-indicated chest (n=5) and abdomen/pelvis (n=5) scans on a Siemens CT scanner, both CT localizer radiograph (“topogram”) and image data were collected. Methods were devised to estimate themore » complete x-y-z TCM scheme using patient attenuation data: (a) available in the Siemens CT localizer radiograph/topogram itself (“actual-topo”) and (b) from a simulated topogram (“sim-topo”) derived from a projection of the image data. For comparison, the actual TCM scheme was extracted from the projection data of each patient. For validation, Monte Carlo simulations were performed using each TCM scheme to estimate dose to the lungs (chest scans) and liver (abdomen/pelvis scans). Organ doses from simulations using the actual TCM were compared to those using each of the estimated TCM methods (“actual-topo” and “sim-topo”). Results: For chest scans, the average differences between doses estimated using actual TCM schemes and estimated TCM schemes (“actual-topo” and “sim-topo”) were 3.70% and 4.98%, respectively. For abdomen/pelvis scans, the average differences were 5.55% and 6.97%, respectively. Conclusion: Strong agreement between doses estimated using actual and estimated TCM schemes validates the methods for simulating Siemens topograms and converting attenuation data into TCM schemes. This indicates that the methods developed in this work can be used to accurately estimate TCM schemes for any patient model or computational phantom, whether a CT localizer radiograph is available or not. Funding Support: NIH Grant R01-EB017095; Disclosures - Michael McNitt-Gray: Institutional Research Agreement, Siemens AG; Research Support, Siemens AG; Consultant, Flaherty Sensabaugh Bonasso PLLC; Consultant, Fulbright and Jaworski; Disclosures - Cynthia McCollough: Research Grant, Siemens Healthcare.« less

  16. Burnout, depression and depersonalisation--psychological factors and coping strategies in dental and medical students.

    PubMed

    Prinz, Patrick; Hertrich, Klaus; Hirschfelder, Ursula; de Zwaan, Martina

    2012-01-01

    Previous studies found that stress, depression, burnout, anxiety, and depersonalisation play a significant role amongst dental and medical students. We wanted to examine if students of the University of Erlangen-Nuremberg also would report elevated values as can been found in similar publications. Furthermore, particularly coping strategies were investigated. The data collection took place in April 2008 including 182 dental and medical students of the 4th and 5th academic year at the University of Erlangen-Nuremberg. Demographic data and the following screening instruments were used: Maslach Burnout Inventory (MBI), Cambridge Depersonalisation Scale (CDS-9), Hospital Anxiety and Depression Scale (HADS), Brief COPE. Descriptive statistics showed higher pathological values in dental students than in medical students. The difference was especially pronounced on the depersonalisation scale (CDS-9), with 20.4% of the dental students, but only 5.5% of the medical students showing scores above a cut-off of 19. The scores decreased in the course of 3 semesters of dentistry. The students with elevated values showed a higher degree of dysfunctional coping. Our results obtained with the screening instruments are in line with the results of previous investigations of other authors and point out the importance of this issue. It might be useful to develop programs teaching dental students more adaptive coping strategies before their first patient contact.

  17. Burnout, depression and depersonalisation – Psychological factors and coping strategies in dental and medical students

    PubMed Central

    Prinz, Patrick; Hertrich, Klaus; Hirschfelder, Ursula; de Zwaan, Martina

    2012-01-01

    Background: Previous studies found that stress, depression, burnout, anxiety, and depersonalisation play a significant role amongst dental and medical students. We wanted to examine if students of the University of Erlangen-Nuremberg also would report elevated values as can been found in similar publications. Furthermore, particularly coping strategies were investigated. Methods: The data collection took place in April 2008 including 182 dental and medical students of the 4th and 5th academic year at the University of Erlangen-Nuremberg. Demographic data and the following screening instruments were used: Maslach Burnout Inventory (MBI), Cambridge Depersonalisation Scale (CDS-9), Hospital Anxiety and Depression Scale (HADS), Brief COPE. Results: Descriptive statistics showed higher pathological values in dental students than in medical students. The difference was especially pronounced on the depersonalisation scale (CDS-9), with 20.4% of the dental students, but only 5.5% of the medical students showing scores above a cut-off of 19. The scores decreased in the course of 3 semesters of dentistry. The students with elevated values showed a higher degree of dysfunctional coping. Conclusion: Our results obtained with the screening instruments are in line with the results of previous investigations of other authors and point out the importance of this issue. It might be useful to develop programs teaching dental students more adaptive coping strategies before their first patient contact. PMID:22403595

  18. Piezoelectric Composite Micromachined Multifrequency Transducers for High-Resolution, High-Contrast Ultrasound Imaging for Improved Prostate Cancer Assessment

    DTIC Science & Technology

    2014-08-01

    and in (b) a standard animal model of prostate cancer. In the preliminary in-vitro study , imaging resolution, contrast to tissue ratio, and lesion...detectability will be assessed relative to a Siemens EV- 8C4 transrectal ultrasound probe. In the in-vivo study , molecular imaging and microvascular...lesions will be imaged at several axial depths using our prototype array and the Siemens EV-8C4 clinical TRUS probe. A blinded reader study will be

  19. International Conference on Defects in Semiconductors (19th), ICDS-19, Held in Aveiro, Portugal on 21-25 July 1997, Part 2

    DTIC Science & Technology

    1998-01-23

    W. Moench (Duisburg) H. Mughrabi (Erlangen) H. Neuhäuser (Braunschweig) J. Pollmann (Münster) H.-E. Schaefer (Stuttgart) J.-B. Suck (Chemnitz...et al . [4]) and also for the silicon vacancy Vacsi [5] the hyperfine interaction (hfi) constants e.g. are remarkably insensitive to the polytype and...TMs are tetrahedrally surrounded by four C ligands (TMyc in the notation of Wang et al . [6]) or by four Si (TMTgi) ligands. Computational. In our

  20. Flight Test Measurement Techniques for Laminar Flow. Volume 23(Les techniques de mesure en vol des ecoulements laminaires)

    DTIC Science & Technology

    2003-10-01

    Chapter 1 – Introduction 1-1 Chapter 2 – Boundary Layer Transition and Laminar Flow Concepts 2-1 2.1 Transition Mechanisms and Transition Prediction 2...Laminar flow control LSTM Lehrstuhl für Strömungsmechanik der Universität Erlangen LWK Laminarwindkanal Stuttgart L2F Laser two-focus anemometer MMO...2.1 Transition mechanisms and transition prediction Modern transonic transport aircraft are characterized by a swept wing resulting in high cruise

  1. Economic feeder for recharging and ``topping off''

    NASA Astrophysics Data System (ADS)

    Fickett, Bryan; Mihalik, G.

    2000-04-01

    Increasing the size of the melt charge significantly increases yield and reduces costs. Siemens Solar Industries is optimizing a method to charge additional material after meltdown (top-off) using an external feeder system. A prototype feeder system was fabricated consisting of a hopper and feed delivery system. The low-cost feeder is designed for simple operation and maintenance. The system is capable of introducing up to 60 kg of granular silicon while under vacuum. An isolation valve permits refilling of the hopper while maintaining vacuum in the growth furnace. Using the feeder system in conjunction with Siemens Solar Industries' energy efficient hot zone dramatically reduces power and argon consumption. Throughput is also improved as faster pull speeds can be attained. The increased pull speeds have an even greater impact when the charge size is increased. Further cost reduction can be achieved by refilling the crucible after crystal growth and pulling a second ingot run. Siemens Solar Industries is presently testing the feeder in production.

  2. Development of superconducting power devices in Europe

    NASA Astrophysics Data System (ADS)

    Tixador, Pascal

    2010-11-01

    Europe celebrated last year (2008) the 100-year anniversary of the first liquefaction of helium by H. Kammerling Onnes in Leiden. It led to the discovery of superconductivity in 1911. Europe is still active in the development of superconducting (SC) devices. The discovery of high critical temperature materials in 1986, again in Europe, has opened a lot of opportunities for SC devices by broking the 4 K cryogenic bottleneck. Electric networks experience deep changes due to the emergence of dispersed generation (renewable among other) and to the advances in ICT (Information Communication Technologies). The networks of the future will be "smart grids". Superconductivity will offer "smart" devices for these grids like FCL (Fault Current Limiter) or VLI (Very Low Inductance) cable and would certainly play an important part. Superconductivity also will participate to the required sustainable development by lowering the losses and enhancing the mass specific powers. Different SC projects in Europe will be presented (Cable, FCL, SMES, Flywheel and Electrical Machine) but the description is not exhaustive. Nexans has commercialized the first two FCLs without public funds in the European grid (UK and Germany). The Amsterdam HTS cable is an exciting challenge in term of losses for long SC cables. European companies (Nexans, Air Liquide, Siemens, Converteam, …) are also very active for projects outside Europe (LIPA, DOE FCL, …).

  3. Shear wave elastography with a new reliability indicator.

    PubMed

    Dietrich, Christoph F; Dong, Yi

    2016-09-01

    Non-invasive methods for liver stiffness assessment have been introduced over recent years. Of these, two main methods for estimating liver fibrosis using ultrasound elastography have become established in clinical practice: shear wave elastography and quasi-static or strain elastography. Shear waves are waves with a motion perpendicular (lateral) to the direction of the generating force. Shear waves travel relatively slowly (between 1 and 10 m/s). The stiffness of the liver tissue can be assessed based on shear wave velocity (the stiffness increases with the speed). The European Federation of Societies for Ultrasound in Medicine and Biology has published Guidelines and Recommendations that describe these technologies and provide recommendations for their clinical use. Most of the data available to date has been published using the Fibroscan (Echosens, France), point shear wave speed measurement using an acoustic radiation force impulse (Siemens, Germany) and 2D shear wave elastography using the Aixplorer (SuperSonic Imagine, France). More recently, also other manufacturers have introduced shear wave elastography technology into the market. A comparison of data obtained using different techniques for shear wave propagation and velocity measurement is of key interest for future studies, recommendations and guidelines. Here, we present a recently introduced shear wave elastography technology from Hitachi and discuss its reproducibility and comparability to the already established technologies.

  4. Shear wave elastography with a new reliability indicator

    PubMed Central

    Dong, Yi

    2016-01-01

    Non-invasive methods for liver stiffness assessment have been introduced over recent years. Of these, two main methods for estimating liver fibrosis using ultrasound elastography have become established in clinical practice: shear wave elastography and quasi-static or strain elastography. Shear waves are waves with a motion perpendicular (lateral) to the direction of the generating force. Shear waves travel relatively slowly (between 1 and 10 m/s). The stiffness of the liver tissue can be assessed based on shear wave velocity (the stiffness increases with the speed). The European Federation of Societies for Ultrasound in Medicine and Biology has published Guidelines and Recommendations that describe these technologies and provide recommendations for their clinical use. Most of the data available to date has been published using the Fibroscan (Echosens, France), point shear wave speed measurement using an acoustic radiation force impulse (Siemens, Germany) and 2D shear wave elastography using the Aixplorer (SuperSonic Imagine, France). More recently, also other manufacturers have introduced shear wave elastography technology into the market. A comparison of data obtained using different techniques for shear wave propagation and velocity measurement is of key interest for future studies, recommendations and guidelines. Here, we present a recently introduced shear wave elastography technology from Hitachi and discuss its reproducibility and comparability to the already established technologies. PMID:27679731

  5. Usefulness of post mortem computed tomography versus conventional forensic autopsy of road accident victims (drivers and passengers).

    PubMed

    Moskała, Artur; Woźniak, Krzysztof; Kluza, Piotr; Romaszko, Karol; Lopatin, Oleksiy

    2017-01-01

    Aim of the study: Deaths of in-vehicle victims (drivers and passengers) of road accidents represent a significant group of issues addressed by forensic medicine. Expressing opinions in this regard involves first of all the determination of the cause of death and the forensic pathologist's participation in the process of road accident reconstruction through defining the mechanism of bodily harm. The scope of the opinion as well as its accuracy and degree of detail largely depend on the scope of forensic autopsy. In this context, techniques that broaden the capabilities of standard autopsy are of particular importance. This paper compares the results of post mortem computed tomography (PMCT) of road accident victims (drivers and passengers) against the results of standard examination in order to determine the scope to which PMCT significantly enhances autopsy capabilities. Material and methods: The analysis covers 118 in-vehicle victims (drivers and passengers) examined from 2012 to 2014. In each case, post-mortem examination was preceded by PMCT examination using Somatom Emotion 16 (Siemens AG, Germany). Results: The results are presented in a tabular form. Conclusions: In most road accident victims (drivers and passengers), post mortem computed tomography significantly increases the results' degree of detail, particularly with regard to injuries of bones and gas collections.

  6. In vivo imaging of superficial femoral artery (SFA) stents for deformation analysis

    NASA Astrophysics Data System (ADS)

    Ganguly, A.; Schneider, A.; Keck, B.; Bennett, N. R.; Fahrig, R.

    2008-03-01

    A high-resolution (198 μm) C-arm CT imaging system (Axiom Artis dTA, Siemens Medical Solutions, Forchheim, Germany) was optimized for imaging superficial femoral artery (SFA) stents in humans. The SFA is susceptible to the development of atherosclerotic lesions. These are typically treated with angioplasty and stent deployment. However, these stents can have a fracture rate as high as 35%. Fracture is usually accompanied by restenosis and reocclusion. The exact cause of breakage is unknown and is hypothesized to result from deforming forces due to hip and knee flexion. Imaging was performed with the leg placed in both straight and bent positions. Projection images obtained during 20 s scans with ~200° of rotation of the C-arm were back-projected to obtain 3D volumes. Using a semi-automatic software algorithm developed in-house, the stent centerlines were found and ellipses were fitted to the slice normals. Image quality was adequate for calculations in 11/13 subjects. Bending the leg was found to shorten the stents in 10/11 cases with the maximum change being 9% (12 mm in a 133 mm stent), and extend the stent in one case by 1.6%. The maximum eccentricity change was 36% with a bend angle of 72° in a case where the stent extended behind the knee.

  7. Environmental testing of CIS based modules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willett, D.

    1995-11-01

    This report describes environmental testing of Siemen`s CIS modules. Charts and diagrams are presented on data concerning: temporary power loss of laminated mini-modules; the 50 thermal cycle test; the 10 humidity freeze cycle test; results after 1000 hours of exposure to damp heat; and interconnect test structures in damp heat testing. It is concluded that moisture ingress causes permanent increases in the series resistance of modules, and that improved packaging is needed for better high humidity reliability. Also, dry dark heat caused temporary power losses which were recovered in sunlight.

  8. First multimodal embolization particles visible on x-ray/computed tomography and magnetic resonance imaging.

    PubMed

    Bartling, Soenke H; Budjan, Johannes; Aviv, Hagit; Haneder, Stefan; Kraenzlin, Bettina; Michaely, Henrik; Margel, Shlomo; Diehl, Steffen; Semmler, Wolfhard; Gretz, Norbert; Schönberg, Stefan O; Sadick, Maliha

    2011-03-01

    Embolization therapy is gaining importance in the treatment of malignant lesions, and even more in benign lesions. Current embolization materials are not visible in imaging modalities. However, it is assumed that directly visible embolization material may provide several advantages over current embolization agents, ranging from particle shunt and reflux prevention to improved therapy control and follow-up assessment. X-ray- as well as magnetic resonance imaging (MRI)-visible embolization materials have been demonstrated in experiments. In this study, we present an embolization material with the property of being visible in more than one imaging modality, namely MRI and x-ray/computed tomography (CT). Characterization and testing of the substance in animal models was performed. To reduce the chance of adverse reactions and to facilitate clinical approval, materials have been applied that are similar to those that are approved and being used on a routine basis in diagnostic imaging. Therefore, x-ray-visible Iodine was combined with MRI-visible Iron (Fe3O4) in a macroparticle (diameter, 40-200 μm). Its core, consisting of a copolymerized monomer MAOETIB (2-methacryloyloxyethyl [2,3,5-triiodobenzoate]), was coated with ultra-small paramagnetic iron oxide nanoparticles (150 nm). After in vitro testing, including signal to noise measurements in CT and MRI (n = 5), its ability to embolize tissue was tested in an established tumor embolization model in rabbits (n = 6). Digital subtraction angiography (DSA) (Integris, Philips), CT (Definition, Siemens Healthcare Section, Forchheim, Germany), and MRI (3 Tesla Magnetom Tim Trio MRI, Siemens Healthcare Section, Forchheim, Germany) were performed before, during, and after embolization. Imaging signal changes that could be attributed to embolization particles were assessed by visual inspection and rated on an ordinal scale by 3 radiologists, from 1 to 3. Histologic analysis of organs was performed. Particles provided a sufficient image contrast on DSA, CT (signal to noise [SNR], 13 ± 2.5), and MRI (SNR, 35 ± 1) in in vitro scans. Successful embolization of renal tissue was confirmed by catheter angiography, revealing at least partial perfusion stop in all kidneys. Signal changes that were attributed to particles residing within the kidney were found in all cases in all the 3 imaging modalities. Localization distribution of particles corresponded well in all imaging modalities. Dynamic imaging during embolization provided real-time monitoring of the inflow of embolization particles within DSA, CT, and MRI. Histologic visualization of the residing particles as well as associated thrombosis in renal arteries could be performed. Visual assessment of the likelihood of embolization particle presence received full rating scores (153/153) after embolization. Multimodal-visible embolization particles have been developed, characterized, and tested in vivo in an animal model. Their implementation in clinical radiology may provide optimization of embolization procedures with regard to prevention of particle misplacement and direct intraprocedural visualization, at the same time improving follow-up examinations by utilizing the complementary characteristics of CT and MRI. Radiation dose savings can also be considered. All these advantages could contribute to future refinements and improvements in embolization therapy. Additionally, new approaches in embolization research may open up.

  9. Evaluation of clinical image processing algorithms used in digital mammography.

    PubMed

    Zanca, Federica; Jacobs, Jurgen; Van Ongeval, Chantal; Claus, Filip; Celis, Valerie; Geniets, Catherine; Provost, Veerle; Pauwels, Herman; Marchal, Guy; Bosmans, Hilde

    2009-03-01

    Screening is the only proven approach to reduce the mortality of breast cancer, but significant numbers of breast cancers remain undetected even when all quality assurance guidelines are implemented. With the increasing adoption of digital mammography systems, image processing may be a key factor in the imaging chain. Although to our knowledge statistically significant effects of manufacturer-recommended image processings have not been previously demonstrated, the subjective experience of our radiologists, that the apparent image quality can vary considerably between different algorithms, motivated this study. This article addresses the impact of five such algorithms on the detection of clusters of microcalcifications. A database of unprocessed (raw) images of 200 normal digital mammograms, acquired with the Siemens Novation DR, was collected retrospectively. Realistic simulated microcalcification clusters were inserted in half of the unprocessed images. All unprocessed images were subsequently processed with five manufacturer-recommended image processing algorithms (Agfa Musica 1, IMS Raffaello Mammo 1.2, Sectra Mamea AB Sigmoid, Siemens OPVIEW v2, and Siemens OPVIEW v1). Four breast imaging radiologists were asked to locate and score the clusters in each image on a five point rating scale. The free-response data were analyzed by the jackknife free-response receiver operating characteristic (JAFROC) method and, for comparison, also with the receiver operating characteristic (ROC) method. JAFROC analysis revealed highly significant differences between the image processings (F = 8.51, p < 0.0001), suggesting that image processing strongly impacts the detectability of clusters. Siemens OPVIEW2 and Siemens OPVIEW1 yielded the highest and lowest performances, respectively. ROC analysis of the data also revealed significant differences between the processing but at lower significance (F = 3.47, p = 0.0305) than JAFROC. Both statistical analysis methods revealed that the same six pairs of modalities were significantly different, but the JAFROC confidence intervals were about 32% smaller than ROC confidence intervals. This study shows that image processing has a significant impact on the detection of microcalcifications in digital mammograms. Objective measurements, such as described here, should be used by the manufacturers to select the optimal image processing algorithm.

  10. Application of NX Siemens PLM software in educational process in preparing students of engineering branch

    NASA Astrophysics Data System (ADS)

    Sadchikova, G. M.

    2017-01-01

    This article discusses the results of the introduction of computer-aided design NX by Siemens Plm Software to the classes of a higher education institution. The necessity of application of modern information technologies in teaching students of engineering profile and selection of a software product is substantiated. The author describes stages of the software module study in relation to some specific courses, considers the features of NX software, which require the creation of standard and unified product databases. The article also gives examples of research carried out by the students with the various software modules.

  11. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bieniosek, Matthew F.; Lee, Brian J.; Levin, Craig S., E-mail: cslevin@stanford.edu

    Purpose: Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial “Micro Deluxe” phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom withmore » sub-mm features. Methods: CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results: Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. Conclusions: This work shows that 3D printed phantoms can be functionally equivalent to commercially available phantoms. They are a viable option for quickly distributing and fabricating low cost, customized phantoms.« less

  12. Technical performance of lactate biosensors and a test-strip device during labour.

    PubMed

    Luttkus, A K; Fotopoulou, C; Sehouli, J; Stupin, J; Dudenhausen, J W

    2010-04-01

    Lactate in fetal blood has a high diagnostic power to detect fetal compromise due to hypoxia, as lactate allows an estimation of duration and intensity of metabolic acidemia. Biosensor technology allows an instantaneous diagnosis of fetal compromise in the delivery room. The goal of the current investigation is to define the preanalytical and analytical biases of this technology under routine conditions in a labour ward in comparison to test-strip technology, which allows measurement of lactate alone. Three lactate biosensors (RapidLab 865, Siemens Medical Solutions Diagnostics, Bad Nauheim, Germany; Radiometer ABL625 and ABL 700, Radiometer Copenhagen, Denmark) and one test-strip device (Lactate Pro, Oxford Instruments, UK) were evaluated regarding precision in serial and repetitive measurements in over 1350 samples of fetal whole blood. The coefficient of variation (CV) and the standard deviation (SD) were calculated. The average value of all three biosensors was defined as an artificial reference value (refval). Blood tonometry was performed in order to test the quality of respiratory parameters and to simulate conditions of fetal hypoxia (pO (2): 10 and 20 mmHg). The precision of serial measurements of all biosensors indicated a coefficient of variation (CV) between 1.55 and 3.16% with an SD from 0.042 to 0.053 mmol/L. The test-strip device (Lactate Pro) mounted to 0.117 mmol/L and 3.99% (SD, CV). When compared to our reference value (refval) ABL 625 showed the closest correlation of -0.1%, while Siemens RapidLab 865 showed an overestimation of +8.9%, ABL700 an underestimation of -6.2% and Lactate Pro of -3.7%. For routine use all tested biosensors show sufficient precision. The test-strip device shows a slightly higher standard deviation. A direct comparison of measured lactate values from the various devices needs to be interpreted with caution as each method detects different lactate concentrations. Furthermore, the 40 min process of tonometry led to an increase of SD and coefficient of variation in all devices. This results in the important preanalytical finding that the precision of replicated measurements worsens significantly with time. The clinician should be aware of the type of analyser used and of preanalytical biases before making clinical decisions on the basis of lactate values.

  13. Our solution for fusion of simultaneusly acquired whole body scintigrams and optical images, as usesful tool in clinical practice in patients with differentiated thyroid carcinomas after radioiodine therapy. A useful tool in clinical practice.

    PubMed

    Matovic, Milovan; Jankovic, Milica; Barjaktarovic, Marko; Jeremic, Marija

    2017-01-01

    After radioiodine therapy of differentiated thyroid cancer (DTC) patients, whole body scintigraphy (WBS) is standard procedure before releasing the patient from the hospital. A common problem is the precise localization of regions where the iod-avide tissue is located. Sometimes is practically impossible to perform precise topographic localization of such regions. In order to face this problem, we have developed a low-cost Vision-Fusion system for web-camera image acquisition simultaneously with routine scintigraphic whole body acquisition including the algorithm for fusion of images given from both cameras. For image acquisition in the gamma part of the spectra we used e.cam dual head gamma camera (Siemens, Erlangen, Germany) in WBS modality, with matrix size of 256×1024 pixels and bed speed of 6cm/min, equipped with high energy collimator. For optical image acquisition in visible part of spectra we have used web-camera model C905 (Logitech, USA) with Carl Zeiss® optics, native resolution 1600×1200 pixels, 34 o field of view, 30g weight, with autofocus option turned "off" and auto white balance turned "on". Web camera is connected to upper head of gamma camera (GC) by a holder of lightweight aluminum rod and a plexiglas adapter. Our own Vision-Fusion software for image acquisition and coregistration was developed using NI LabVIEW programming environment 2015 (National Instruments, Texas, USA) and two additional LabVIEW modules: NI Vision Acquisition Software (VAS) and NI Vision Development Module (VDM). Vision acquisition software enables communication and control between laptop computer and web-camera. Vision development module is image processing library used for image preprocessing and fusion. Software starts the web-camera image acquisition before starting image acquisition on GC and stops it when GC completes the acquisition. Web-camera is in continuous acquisition mode with frame rate f depending on speed of patient bed movement v (f=v/∆ cm , where ∆ cm is a displacement step that can be changed in Settings option of Vision-Fusion software; by default, ∆ cm is set to 1cm corresponding to ∆ p =15 pixels). All images captured while patient's bed is moving are processed. Movement of patient's bed is checked using cross-correlation of two successive images. After each image capturing, algorithm extracts the central region of interest (ROI) of the image, with the same width as captured image (1600 pixels) and the height that is equal to the ∆ p displacement in pixels. All extracted central ROI are placed next to each other in the overall whole-body image. Stacking of narrow central ROI introduces negligible distortion in the overall whole-body image. The first step for fusion of the scintigram and the optical image was determination of spatial transformation between them. We have made an experiment with two markers (point radioactivity sources of 99m Tc pertechnetate 1MBq) visible in both images (WBS and optical) to find transformation of coordinates between images. The distance between point markers is used for spatial coregistration of the gamma and optical images. At the end of coregistration process, gamma image is rescaled in spatial domain and added to the optical image (green or red channel, amplification changeable from user interface). We tested our system for 10 patients with DTC who received radioiodine therapy (8 women and two men, with average age of 50.10±12.26 years). Five patients received 5.55Gbq, three 3.70GBq and two 1.85GBq. Whole-body scintigraphy and optical image acquisition were performed 72 hours after application of radioiodine therapy. Based on our first results during clinical testing of our system, we can conclude that our system can improve diagnostic possibility of whole body scintigraphy to detect thyroid remnant tissue in patients with DTC after radioiodine therapy.

  14. [Werner Leibbrand, Annemarie Wettley and controversies on "euthanasia" the background of medico-historical and ethical debates in the Post World War II era].

    PubMed

    Wiesinger, Christine; Frewer, Andreas

    2014-01-01

    Psychiatrists and medical historians Werner Leibbrand (1896 - 1974) and Annemarie Wettley (1913 - 1996) are amongst the most striking figures in the field of history of medicine. Leibbrand was appointed director of the "Heil- und Pflegeanstalt" in Erlangen shortly after the war. Fuelled by his own experiences of suppression and persecution during the Nazi era he promised to unearth the crimes and atrocities which had happened under watch of the Nazi regime. He was joined by Annemarie Wettley, who worked as a physician at the hospital and had developed an increasing interest in the history of medicine. In 1946 they published "Um die Menschenrechte der Geisteskranken" ("Human Rights of the Mentally Ill") about the "euthanasia" campaign of the Nazi regime. Although a number of substantial works followed, Leibbrand and Wettley failed to inform in more depth on crimes and atrocities, for instance killings of patients and forced malnutrition. Doubts and charges against Wettley regarding her role in dietary programmes at the Erlangen hospital and against Leibbrand regarding special expert's reports--both had a short-term arrest warrant--might have contributed to stagnation in their efforts. In 1953 Leibbrand accepted the offer of a chair at the University in Munich, Wettley followed and habilitated in history of medicine; in the year 1962 they married. Contacts and exchange amongst medico-historical experts shed light on developments during the post-war era; still, a critical and fundamental review of the crimes within the medical system of the Nazi regime did not take place during this time.

  15. Preface

    NASA Astrophysics Data System (ADS)

    Schuh, S.; Handler, G.

    2009-03-01

    The Joint European and National Astronomy Meeting 2008 (JENAM 2008) was held from September 8-12, 2008 in Vienna, Austria, as the joint meeting of the Austrian Society of Astronomy and Astrophysics (ÖGAA), the Astronomische Gesellschaft (AG), and the European Astronomical Society (EAS). It hosted nine symposia under the overall topic ''New Challenges To European Astronomy''. This special volume of Communications in Asteroseismology holds the proceedings of the JENAM 2008 Symposium No 4: ''Asteroseismology and Stellar Evolution''. The Asteroseismology and Stellar Evolution Symposium has been generously sponsored by the ÖGAA, by the HELAS Forum (an activity of the European Helio- and Asteroseismology Network, initiative funded by the European Commission since April 1st, 2006, as a Co-ordination Action under its Sixth Framework Programme, FP6), and by the Kulturabteilung der Stadt Wien (Magistratsabteilung 7). The Symposium program was put together by the Scientific Organizing Committee consisting of Conny Aerts (University of Leuven, Belgium), Annie Baglin (Observatoire de Paris, France), Wolfgang Glatzel (University of Göttingen, Germany), Gerald Handler (University of Vienna, Austria, Co-convener), Uli Heber (University of Erlangen-Nürnberg, Germany), Katrien Kolenberg (University of Vienna, Austria), Suzanna Randall (European Southern Observatory) and Sonja Schuh (University of Göttingen, Germany, Convener). Out of a total of 60 oral and poster contributions, 15 contributed talks were selected for presentation during the three half-day session program, with ample time for questions and discussion. There also was an opportunity to introduce the poster contributions during 2-min oral presentations. The scientific topics covered diverse object classes divided into Stochastically excited pulsators (main sequence, red giants, AGB supergiants), Heat-driven pulsators along the main sequence, and Compact pulsators, as well as additional topics that we have summarized as contributions on Eruptive variable and binary stars, and contributions presenting Methods and tools. The three session topics were introduced by two invited review speakers per field. In the first session, Jadwiga Daszynska-Daszkiewicz summarized current ''Challenges for stellar pulsation and evolution theory'', and Konstanze Zwintz reported ''A preliminary glimpse on CoRoT results and expectations'' (for Eric Michel), together giving an overview of the observational and theoretical status of the field. Anne Thoul and Oleg Kochukhov presented the state of the art in ''Asteroseismology of B stars'' and ''Asteroseismology of chemically peculiar stars'', respectively, in the second session, highlighting the hot issues in understanding and interpreting the pulsational behaviour of these groups. The stellar evolution aspect was given special consideration in ''Asteroseismology and Evolution of EHB stars'' by Roy Østensen and ''Asteroseismology and evolution of GW Vir stars'' by Pierre-Oliver Quirion in the concluding third session. A dedicated audience (on average 45 participants in each session), the excellent speakers, and our colleague Patrick Lenz who acted as the friendly and competent technician made this Symposium a highly interesting, enjoyable and successful event. We would like to thank all speakers, poster authors, and participants for coming to Vienna, the SOC and the referees for their work, the local organizers at Vienna for providing all the necessary infrastructure, and all sponsors for having made possible this event and the proceedings at hand.

  16. Effect of filters and reconstruction algorithms on I-124 PET in Siemens Inveon PET scanner

    NASA Astrophysics Data System (ADS)

    Ram Yu, A.; Kim, Jin Su

    2015-10-01

    Purpose: To assess the effects of filtering and reconstruction on Siemens I-124 PET data. Methods: A Siemens Inveon PET was used. Spatial resolution of I-124 was measured to a transverse offset of 50 mm from the center FBP, 2D ordered subset expectation maximization (OSEM2D), 3D re-projection algorithm (3DRP), and maximum a posteriori (MAP) methods were tested. Non-uniformity (NU), recovery coefficient (RC), and spillover ratio (SOR) parameterized image quality. Mini deluxe phantom data of I-124 was also assessed. Results: Volumetric resolution was 7.3 mm3 from the transverse FOV center when FBP reconstruction algorithms with ramp filter was used. MAP yielded minimal NU with β =1.5. OSEM2D yielded maximal RC. SOR was below 4% for FBP with ramp, Hamming, Hanning, or Shepp-Logan filters. Based on the mini deluxe phantom results, an FBP with Hanning or Parzen filters, or a 3DRP with Hanning filter yielded feasible I-124 PET data.Conclusions: Reconstruction algorithms and filters were compared. FBP with Hanning or Parzen filters, or 3DRP with Hanning filter yielded feasible data for quantifying I-124 PET.

  17. Shielding evaluation for IMRT implementation in an existing accelerator vault

    PubMed Central

    Price, R. A.; Chibani, O.; Ma, C.‐M.

    2003-01-01

    A formalism is developed for evaluating the shielding in an existing vault to be used for IMRT. Existing exposure rate measurements are utilized as well as a newly developed effective modulation scaling factor. Examples are given for vaults housing 6, 10 and 18 MV linear accelerators. The use of an 18 MV Siemens linear accelerator is evaluated for IMRT delivery with respect to neutron production and the effects on individual patients. A modified modulation scaling factor is developed and the risk of the incurrence of fatal secondary malignancies is estimated. The difference in neutron production between 18 MV Varian and Siemens accelerators is estimated using Monte Carlo results. The neutron production from the Siemens accelerator is found to be approximately 4 times less than that of the Varian accelerator resulting in a risk of fatal secondary malignancy occurrence of approximately 1.6% when using the SMLC delivery technique and our measured modulation scaling factors. This compares with a previously published value of 1.6% for routine 3D CRT delivery on the Varian accelerator. PACS number(s): 87.52.Ga, 87.52.Px, 87.53.Qc, 87.53.Wz PMID:12841794

  18. Performance parameters of a liquid filled ionization chamber array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poppe, B.; Stelljes, T. S.; Looe, H. K.

    2013-08-15

    Purpose: In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in clinical photon-beam dosimetry are investigated.Methods: Measurements were carried out at an Elekta Synergy and Siemens Primus accelerator. For measurements of stability, linearity, and saturation effects of the 1000SRS array a Semiflex 31013 ionization chamber (PTW-Freiburg, Germany) was used as a reference. The effective point of measurement was determined by TPR measurements of the array in comparison with a Roos chamber (type 31004, PTW-Freiburg, Germany). The response of the array with varying field size and depth of measurement was evaluatedmore » using a Semiflex 31010 ionization chamber as a reference. Output factor measurements were carried out with a Semiflex 31010 ionization chamber, a diode (type 60012, PTW-Freiburg, Germany), and the detector array under investigation. The dose response function for a single detector of the array was determined by measuring 1 cm wide slit-beam dose profiles and comparing them against diode-measured profiles. Theoretical aspects of the low pass properties and of the sampling frequency of the detector array were evaluated. Dose profiles measured with the array and the diode detector were compared, and an intensity modulated radiation therapy (IMRT) field was verified using the Gamma-Index method and the visualization of line dose profiles.Results: The array showed a short and long term stability better than 0.1% and 0.2%, respectively. Fluctuations in linearity were found to be within ±0.2% for the vendor specified dose range. Saturation effects were found to be similar to those reported in other studies for liquid-filled ionization chambers. The detector's relative response varied with field size and depth of measurement, showing a small energy dependence accounting for maximum signal deviations of ±2.6% from the reference condition for the setup used. The σ-values of the Gaussian dose response function for a single detector of the array were found to be (0.72 ± 0.25) mm at 6 MV and (0.74 ± 0.25) mm at 15 MV and the corresponding low pass cutoff frequencies are 0.22 and 0.21 mm{sup −1}, respectively. For the inner 5 × 5 cm{sup 2} region and the outer 11 × 11 cm{sup 2} region of the array the Nyquist theorem is fulfilled for maximum sampling frequencies of 0.2 and 0.1 mm{sup −1}, respectively. An IMRT field verification with a Gamma-Index analysis yielded a passing rate of 95.2% for a 3 mm/3% criterion with a TPS calculation as reference.Conclusions: This study shows the applicability of the Octavius 1000SRS in modern dosimetry. Output factor and dose profile measurements illustrated the applicability of the array in small field and stereotactic dosimetry. The high spatial resolution ensures adequate measurements of dose profiles in regular and intensity modulated photon-beam fields.« less

  19. Determination of lead, cadmium and mercury in blood for assessment of environmental exposure: A comparison between inductively coupled plasma mass spectrometry and atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Palmer, Christopher D.; Lewis, Miles E.; Geraghty, Ciaran M.; Barbosa, Fernando; Parsons, Patrick J.

    2006-08-01

    A biomonitoring method for the determination of Pb, Cd, and Hg at background levels in whole blood by inductively coupled plasma-mass spectrometry is described. While this method was optimized for assessing Pb, Cd and Hg at environmental levels, it also proved suitable for assessing concentrations associated with occupational exposure. The method requires as little as 200 μl of blood that is diluted 1 + 49 for direct analysis in the inductively coupled plasma-mass spectrometer. Method performance is compared to well-established AAS methods. Initial method validation was accomplished using National Institute of Standards and Technology (NIST) Standard Reference Material 966, Toxic Metals in Bovine Blood. Method detection limits (3s) are 0.05 μg dl - 1 for Pb, 0.09 μg l - 1 for Cd; and 0.17 μg l - 1 for Hg. Repeatability ranged from 1.4% to 2.8% for Pb; 3% to 10% for Cd; and 2.6% to 8.8% for Hg. In contrast, AAS method detection limits were 1 μg dl - 1 , 0.54 μg l - 1 , and 0.6 μg l - 1 , for Pb, Cd, and Hg, respectively. Further performance assessments were conducted over a 2-year period via participation in four international External Quality Assessment Schemes (EQAS) operated specifically for toxic metals in blood. This includes schemes operated by (a) the New York State Department of Health's Wadsworth Center, Albany, NY, USA (b) L'Institut National de Santé Publique du Québec, Centre de Toxicologie du Québec, Canada, (c) Friedrich-Alexander University, Erlangen, Germany, and (d) the University of Surrey, Guildford, UK Trace Elements scheme. The EQAS data reflect analytical performance for blind samples analyzed independently by both inductively coupled plasma-mass spectrometry and AAS methods.

  20. The Master's program in Advanced Optical Technologies: an interdisciplinary, international and individual approach

    NASA Astrophysics Data System (ADS)

    Großmann, Jürgen; Schmauss, Bernhard

    2017-08-01

    The Master's Program in Advanced Optical Technologies (MAOT) was established at the Friedrich-Alexander Universität Erlangen-Nürnberg in 2007 as part of the Elite Network of Bavaria (ENB), an initiative by the Bavarian State Government comprising about 40 elite Master's programs and doctoral programs. MAOT can be studied after a Bachelor in physics or an engineering subject. The Master's program realizes an innovative concept combining three core elements: (1) Interdisciplinarity: The program integrates courses and researchers from five engineering subjects and from physics. The degree of interdisciplinarity goes far beyond traditional programs. (2) Internationality: The program is taught entirely in English and special support is given to international students. (3). Individuality: The course curriculum was adapted at several points based on the experience in the initial years. The same is true for the way in which international students are supported and the type of support they need. The students are given an unusually high degree of freedom to develop an individual curriculum and to pursue research projects. Crucial experience and lessons learned are: (1) Lecturers and researchers have to be coordinated and the perspectives of the different disciplines have to be integrated within one program. Students must be guided in order to deal with the demands and challenges of the different disciplines. (2) International students need support with settling in Germany and with learning and working in a German cultural environment. They need support with administrative issues. Furthermore, they need to analyze and understand cultural differences and how they impact on the cooperation between lecturers and students and on the work in research groups. (3) Students must be helped to develop their own curriculum. They must learn how to combine their first-degree qualification with the specialized qualification which they gain after completing their Master's program. They need to develop the skills to match their preferences with what is realistic and feasible.

  1. The effect of a standardised source of divided attention in airway management: A randomised, crossover, interventional manikin study.

    PubMed

    Prottengeier, Johannes; Petzoldt, Marlen; Jess, Nikola; Moritz, Andreas; Gall, Christine; Schmidt, Joachim; Breuer, Georg

    2016-03-01

    Dual-tasking, the need to divide attention between concurrent tasks, causes a severe increase in workload in emergency situations and yet there is no standardised training simulation scenario for this key difficulty. We introduced and validated a quantifiable source of divided attention and investigated its effects on performance and workload in airway management. A randomised, crossover, interventional simulation study. Center for Training and Simulation, Department of Anaesthesiology, Erlangen University Hospital, Germany. One hundred and fifty volunteer medical students, paramedics and anaesthesiologists of all levels of training. Participants secured the airway of a manikin using a supraglottic airway, conventional endotracheal intubation and video-assisted endotracheal intubation with and without the Paced Auditory Serial Addition Test (PASAT), which served as a quantifiable source of divided attention. Primary endpoint was the time for the completion of each airway task. Secondary endpoints were the number of procedural mistakes made and the perceived workload as measured by the National Aeronautics and Space Administration's task load index (NASA-TLX). This is a six-dimensional questionnaire, which assesses the perception of demands, performance and frustration with respect to a task on a scale of 0 to 100. All 150 participants completed the tests. Volunteers perceived our test to be challenging (99%) and the experience of stress and distraction true to an emergency situation (80%), but still fair (98%) and entertaining (95%). The negative effects of divided attention were reproducible in participants of all levels of expertise. Time consumption and perceived workload increased and almost half the participants make procedural mistakes under divided attention. The supraglottic airway technique was least affected by divided attention. The scenario was effective for simulation training involving divided attention in acute care medicine. The significant effects on performance and perceived workload demonstrate the validity of the model, which was also characterised by high acceptability, technical simplicity and a novel degree of standardisation.

  2. The MIRAX Hard X-Ray Transient Mission

    NASA Astrophysics Data System (ADS)

    Rodrigues, Barbara; Braga, J.; Grindlay, J. E.; Allen, B.; Hong, J.; Barthelmy, S. D.; Rothschild, R. E.; Wilms, J.

    2013-01-01

    The MIRAX (Monitor e Imageador de Raios X) mission is designed to perform a hard X-ray (5-200 keV) survey of more than half of the sky with high localization power 1') and high sensitivity (26 mCrab for one orbit and 0.3 mCrab for one year). This will be achieved by a set of 4 coded-mask imagers that will operate in scanning mode in a near-Equatorial circular LEO with a lifetime of 4+ years. The pointing directions will maximize the coverage of the Central Galactic Plane. The main objective of MIRAX is to study with unprecedented depth and time coverage (milliseconds to years) a large sample of transient and variable phenomena on accreting neutron stars and black holes. The high cadence of the MIRAX detections will be well suited for simultaneous and follow-up observations in other wavelengths. The satellite bus and launch will be provided by Brazil, whereas the instrument development is a cooperative effort led by CfA and including INPE (Brazil), UCSD, MIT, NASA's GSFC, Caltech and the University of Erlangen-Nuremberg in Germany. The MIRAX detectors, developed at CfA, are position-sensitive 5mm-thick CdZnTe with 0.6mm pitch with 756 cm2 effective area at 10 keV (total for the 4 units). The energy resolution is ~2 keV at 60 keV. For exposures near the center of the field of view the sensitivity of MIRAX will approach that of Swift/BAT in the 15-150 keV range, whereas the low threshold will enable ~70 mCrab sensitivity on time scales of 100s at energies inaccessible to Swift/BAT and INTEGRAL. The first unit of one MIRAX telescope has been developed and flown in the protoEXIST-2 (P2) balloon experiment in Fort Sumner, NM, in early October 2012. In this work we describe the MIRAX instruments and discuss results of detector calibration and preliminary results of the P2 balloon flight.

  3. Methodology for cloud-based design of robots

    NASA Astrophysics Data System (ADS)

    Ogorodnikova, O. M.; Vaganov, K. A.; Putimtsev, I. D.

    2017-09-01

    This paper presents some important results for cloud-based designing a robot arm by a group of students. Methodology for the cloud-based design was developed and used to initiate interdisciplinary project about research and development of a specific manipulator. The whole project data files were hosted by Ural Federal University data center. The 3D (three-dimensional) model of the robot arm was created using Siemens PLM software (Product Lifecycle Management) and structured as a complex mechatronics product by means of Siemens Teamcenter thin client; all processes were performed in the clouds. The robot arm was designed in purpose to load blanks up to 1 kg into the work space of the milling machine for performing student's researches.

  4. Long-term effects of exercise in postmenopausal women: 16-year results of the Erlangen Fitness and Osteoporosis Prevention Study (EFOPS).

    PubMed

    Kemmler, Wolfgang; Kohl, Matthias; von Stengel, Simon

    2017-01-01

    Multimorbidity related to menopause and/or increased age will put healthcare systems in western nations under ever-greater strain. Effective strategies to prevent diseases are thus of high priority and should be started earlier in life. The purpose of the study was to evaluate the long-term effect of exercise on different important health parameters in initially early postmenopausal women over a 16-year period. In 1998, 137 early postmenopausal women with osteopenia living in Erlangen-Nürnberg were included in the study. Eighty-six women joined the exercise group (EG) and conducted two supervised group and two home training sessions per week, whereas the control group (CG: n = 51) maintained their physical activity level. Primary outcome parameters were clinical overall fractures incidence; secondary study endpoint was Framingham study-based 10-year risk of coronary death/myocardial infarction and low back pain. In 2014, 59 women of the EG and 46 women of the CG were included in the 16-year follow-up analysis. Framingham study-based 10-year risk of myocardial infarction/coronary death increased significantly (P < 0.001) in both groups; however, changes were significantly more favorable in the EG (5.00% ± 2.94% vs CG: 6.90% ± 3.98%; P = 0.02). The ratio for clinical "overall" fractures was 0.47 (95% CI: 0.24-0.92; P = 0.03), and thus significantly lower in the EG. Although we focused on a high-intensity exercise strategy, low back pain was favorably affected in the EG. Multipurpose exercise programs demonstrated beneficial effects on various relevant risk factors and diseases of menopause or/and increased age, and should thus be preferentially applied for primary or secondary prevention in postmenopausal women.

  5. Measurement and control system for cryogenic helium gas bearing turbo-expander experimental platform based on Siemens PLC S7-300

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, J.; Xiong, L. Y.; Peng, N.

    2014-01-29

    An experimental platform for cryogenic Helium gas bearing turbo-expanders is established at the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. This turbo-expander experimental platform is designed for performance testing and experimental research on Helium turbo-expanders with different sizes from the liquid hydrogen temperature to the room temperature region. A measurement and control system based on Siemens PLC S7-300 for this turbo-expander experimental platform is developed. Proper sensors are selected to measure such parameters as temperature, pressure, rotation speed and air flow rate. All the collected data to be processed are transformed and transmitted to S7-300 CPU. Siemensmore » S7-300 series PLC CPU315-2PN/DP is as master station and two sets of ET200M DP remote expand I/O is as slave station. Profibus-DP field communication is established between master station and slave stations. The upper computer Human Machine Interface (HMI) is compiled using Siemens configuration software WinCC V6.2. The upper computer communicates with PLC by means of industrial Ethernet. Centralized monitoring and distributed control is achieved. Experimental results show that this measurement and control system has fulfilled the test requirement for the turbo-expander experimental platform.« less

  6. From first to latest imaging technology: Revisiting the first mummy investigated with X-ray in 1896 by using dual-source computed tomography.

    PubMed

    Zesch, Stephanie; Panzer, Stephanie; Rosendahl, Wilfried; Nance, John W; Schönberg, Stefan O; Henzler, Thomas

    2016-01-01

    The aim of this study was to systematically reinvestigate the first human mummy that was ever analyzed with X-ray imaging in 1896, using dual-source computed tomography (DSCT) in order to compare the earliest and latest imaging technologies, to estimate preservation, age at death, sex, anatomical variants, paleopathological findings, mummification, embalming and wrapping of the child mummy from ancient Egypt. Radiocarbon dating was used to determine the mummy's age and to specify the child's living period in the Egyptian chronology. The ancient Egyptian child mummy is kept in the Senckenberg Museum of Natural History in Frankfurt am Main, Germany. An accelerator mass spectrometer (MICADAS) was used for radiocarbon dating. DSCT was performed using a 2 × 64 slice dual-source CT system (Siemens Healthineers, Forchheim, Germany). A thorough visual examination of the mummy, a systematic radiological evaluation of the DICOM datasets, and established methods in physical anthropology were applied to assess the bio-anthropological data and the post mortem treatment of the body. Radiocarbon dating yielded a calibrated age between 378 and 235 cal BC (95.4% confidence interval), corresponding with the beginning of the Ptolemaic period. The mummy was a male who was four to five years old at the time of death. Remnants of the brain and inner organs were preserved by the embalmers, which is regularly observed in ancient Egyptian child mummies. Skin tissue, inner organs, tendons and/or musculature, cartilage, nerves and vasculature could be identified on the DSCT dataset. The dental health of the child was excellent. Anatomical variants and pathological defects included a congenital Pectus excavatum deformity, hepatomegaly, Harris lines, and longitudinal clefts in the ventral cortices of both femora. Our results highlight the enormous progress achieved form earliest to latest imaging technology for advanced mummy research using the first human mummy investigated with X-ray. With the application of DSCT, detailed knowledge regarding age at death, sex, diseases, death, and mummification of a child from Ptolemaic Egypt are revealed while considering the temporary rites of body treatment and burial for children.

  7. Pooled nucleic acid testing increases the diagnostic yield of acute HIV infections in a high-risk population compared to 3rd and 4th generation HIV enzyme immunoassays.

    PubMed

    Krajden, Mel; Cook, Darrel; Mak, Annie; Chu, Ken; Chahil, Navdeep; Steinberg, Malcolm; Rekart, Michael; Gilbert, Mark

    2014-09-01

    We compared a 3rd generation (gen) and two 4th gen HIV enzyme immunoassays (EIA) to pooled nucleic acid testing (PNAT) for the identification of pre- and early seroconversion acute HIV infection (AHI). 9550 specimens from males >18 year from clinics attended by men who have sex with men were tested by Siemens ADVIA Centaur(®) HIV 1/O/2 (3rd gen) and HIV Combo (4th gen), as well as by Abbott ARCHITECT(®) HIV Ag/Ab Combo (4th gen). Third gen non-reactive specimens were also tested by Roche COBAS(®) Ampliprep/COBAS® TaqMan HIV-1 Test v.2 in pools of 24 samples. Sensitivity and specificity of the three EIAs for AHI detection were compared. 7348 persons contributed 9435 specimens and had no evidence of HIV infection, 79 (94 specimens) had established HIV infection, 6 (9 specimens) had pre-seroconversion AHI and 9 (12 specimens) had early seroconversion AHI. Pre-seroconversion AHI cases were not detected by 3rd gen EIA, whereas 2/6 (33.3%) were detected by Siemens 4th gen, 4/6 (66.7%) by Abbott 4th gen and 6/6 (100%) by PNAT. All three EIAs and PNAT detected all individuals with early seroconversion AHI. Overall sensitivity/specificity for the EIAs relative to WB or NAT resolved infection status was 93.6%/99.9% for Siemens 3rd gen, 95.7%/99.7% for Siemens 4th gen and 97.9%/99.2% for Abbott 4th gen. While both 4th gen EIAs demonstrated improved sensitivity for AHI compared to 3rd gen EIA, PNAT identified more AHI cases than either 4th gen assay. PNAT is likely to remain a useful strategy to identify AHI in high-risk populations. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. TH-AB-207A-09: Tailoring TCM Schemes to a Task: Evaluating the Impact of Customized TCM Profiles On Detection of Lung Nodules in Simulated CT Lung Cancer Screening

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffman, J; McNitt-Gray, M; Noo, F

    Purpose: Recent work has shown that current TCM profile designs boost detection of low-contrast lung lesions in the lung apices, but yield reduced detection performance in the mid and lower lung regions relative to fixed tube current cases. This observed imbalance suggests that the TCM scheme might be tailored in new ways to maximize nodule detection throughout the entire lung. In this work, we begin a preliminary investigation into custom TCM profiles in an attempt to achieve uniform lesion detection throughout the extent of the lung. Methods: Low-contrast (25HU), 6mm nodules representing ground glass opacities were simulated at 1mm intervalsmore » over the length the lungs in a voxelized model of the XCAT phantom, one nodule per lung, per simulated scan. Voxel values represented attenuation values at 80keV. CT projection data was created by simulating a finite focal spot and using Joseph’s method for forward projection; scanner geometry was that of the Siemens Sensation 64 and the X-ray source was simulated as an 80keV monochromatic beam. Noise realizations were created using Poisson statistics, a realistic bowtie filter and varying tube current. 500 noise realizations were created for the custom TCM designs. All reconstruction was done with FreeCT-wFBP. An SKE/BKE task was used in conjunction with a 2D Hotelling Observer to calculate area-under-the-curve (AUC) as a proxy for “detectability.” AUC was plotted as a function of nodule Z-location to create a “detectability map.” The detectability map for the custom TCM curve was qualitatively assessed relative to previous results for the fixed TC and clinical TCM cases for uniformity. Results: Detection uniformity was improved throughout the mid and lower lungs, however detection remained disproportionately high in the upper lung region. Conclusion: Detection uniformity was improved with a custom TC profile. Future work will incorporate an analytic, task-specific approach to optimize the TC scheme for nodule detection. J. Hoffman: Part-time intern, Toshiba Medical Research Institute; M. McNitt-Gray: Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; F. Noo: Institutional research agreement, Siemens Healthcare; Receives research funding from Siemens Healthcare.« less

  9. Accuracy of radiographic caries diagnosis using different X-ray generators.

    PubMed

    Svenson, B; Petersson, A

    1989-05-01

    Dental X-ray machines utilizing five different combinations of X-ray generators and tube voltages (Philips Oralix 65 kV, Siemens Heliodent EC 60 kV, Siemens Heliodent 70 kV, Soredex Minray DC 60 kV and Soredex Minray DC 70 kV) were compared with respect to the accuracy of radiographic diagnosis of proximal caries. Nine observers diagnosed proximal caries in radiographs of extracted premolars. The findings of the observers were compared to the actual presence or absence of caries. The ROC-curve technique was used to evaluate differences in diagnostic accuracy between the X-ray machines. The results showed small differences in diagnostic accuracy between the different X-ray generators but they proved to be statistically non-significant.

  10. The continual innovation of commercial PET/CT solutions in nuclear cardiology: Siemens Healthineers.

    PubMed

    Bendriem, Bernard; Reed, Jessie; McCullough, Kathryn; Khan, Mohammad Raza; Smith, Anne M; Thomas, Damita; Long, Misty

    2018-04-10

    Cardiac PET/CT is an evolving, non-invasive imaging modality that impacts patient management in many clinical scenarios. Beyond offering the capability to assess myocardial perfusion, inflammatory cardiac pathologies, and myocardial viability, cardiac PET/CT also allows for the non-invasive quantitative assessment of myocardial blood flow (MBF) and myocardial flow reserve (MFR). Recognizing the need for an enhanced comprehension of coronary physiology, Siemens Healthineers implemented a sophisticated solution for the calculation of MBF and MFR in 2009. As a result, each aspect of their innovative scanner and image-processing technology seamlessly integrates into an efficient, easy-to-use workflow for everyday clinical use that maximizes the number of patients who potentially benefit from this imaging modality.

  11. Computer-aided detection of acute pulmonary embolism with 64-slice multi-detector row computed tomography: impact of the scanning conditions and overall image quality in the detection of peripheral clots.

    PubMed

    Dewailly, Marion; Rémy-Jardin, Martine; Duhamel, Alain; Faivre, Jean-Baptiste; Pontana, François; Deken, Valérie; Bakai, Anne-Marie; Remy, Jacques

    2010-01-01

    To evaluate the performance of a computer-aided detection (CAD) system for diagnosing peripheral acute pulmonary embolism (PE) with a 64-slice multi-detector row computed tomography (CT). Two radiologists investigated the accuracy of a software aimed at detecting peripheral clots (PECAD prototype, version 7; Siemens Medical Systems, Forchheim, Germany) by applying this tool for the analysis of the pulmonary arterial bed of 74 CT angiograms obtained with 64-slice dual-source CT (Definition; Siemens Medical Systems). These cases were retrospectively selected from a database of CT studies performed on the same CT unit, with a similar collimation (64 x 0.6 mm) and similar injection protocols. Patient selection was based on a variety of (1) scanning conditions, namely, nongated (n = 30), electrocardiography-gated (n = 30), and dual-energy CT angiograms (n = 14), and (2) image quality (IQ), namely, scans of excellent IQ (n = 53) and lower IQ due to lower levels of arterial enhancement and/or presence of noise (n = 21). The standard of truth was based on the 2 radiologists' consensus reading and the results of CAD. The software detected 80 of 93 peripheral clots present in the 21 patients (42 segmental and 38 subsegmental clots). The overall sensitivity (95% confidence interval) of the CAD tool was 86% (77%-92%) for detecting peripheral clots, 78% (64.5%-88%) at the segmental level and 97% (85.5%-99.9%) at the subsegmental level. Assuming normal vascular anatomy with 20 segmental and 40 subsegmental arteries, overall specificity and positive and negative predictive values (95% confidence interval) of the software were 91.8% (91%-92.6%), 18.4% (15%-22.4%), and 99.7% (99.5%-99.8%), respectively. A mean of 5.4 false positives was found per patient (total, 354 false positives), mainly linked to the presence of perivascular connective tissue (n = 119; 34%) and perivascular airspace consolidation (n = 97; 27%). The sensitivities (95% confidence interval) for the CAD tool were 91% (69.8%-99.3%) for dual-energy, 87% (59.3%-93.2%) for electrocardiography-gated, and 87% (73.5%-95.3%) for nongated scans (P > 0.05). No significant difference was found in the sensitivity of the CAD software when comparing the scans according to the scanning conditions and image quality. The evaluated CAD software has a good sensitivity in detecting peripheral PE, which is not influenced by the scanning conditions or the overall image quality.

  12. Development of an imaging-planning program for screen/film and computed radiography mammography for breasts with short chest wall to nipple distance.

    PubMed

    Dong, S L; Su, J L; Yeh, Y H; Chu, T C; Lin, Y C; Chuang, K S

    2011-04-01

    Imaging breasts with a short chest wall to nipple distance (CWND) using a traditional mammographic X-ray unit is a technical challenge for mammographers. The purpose of this study is the development of an imaging-planning program to assist in determination of imaging parameters of screen/film (SF) and computed radiography (CR) mammography for short CWND breasts. A traditional mammographic X-ray unit (Mammomat 3000, Siemens, Munich, Germany) was employed. The imaging-planning program was developed by combining the compressed breast thickness correction, the equivalent polymethylmethacrylate thickness assessment for breasts and the tube loading (mAs) measurement. Both phantom exposures and a total of 597 exposures were used for examining the imaging-planning program. Results of the phantom study show that the tube loading rapidly decreased with the CWND when the automatic exposure control (AEC) detector was not fully covered by the phantom. For patient exposures with the AEC fully covered by breast tissue, the average fractional tube loadings, defined as the ratio of the predicted mAs using the imaging-planning program and mAs of the mammogram, were 1.10 and 1.07 for SF and CR mammograms, respectively. The predicted mAs values were comparable to the mAs values, as determined by the AEC. By applying the imaging-planning program in clinical practice, the experiential dependence of the mammographer for determination of the imaging parameters for short CWND breasts is minimised.

  13. High-pitch computed tomography coronary angiography-a new dose-saving algorithm: estimation of radiation exposure.

    PubMed

    Ketelsen, Dominik; Buchgeister, Markus; Korn, Andreas; Fenchel, Michael; Schmidt, Bernhard; Flohr, Thomas G; Thomas, Christoph; Schabel, Christoph; Tsiflikas, Ilias; Syha, Roland; Claussen, Claus D; Heuschmid, Martin

    2012-01-01

    Purpose. To estimate effective dose and organ equivalent doses of prospective ECG-triggered high-pitch CTCA. Materials and Methods. For dose measurements, an Alderson-Rando phantom equipped with thermoluminescent dosimeters was used. The effective dose was calculated according to ICRP 103. Exposure was performed on a second-generation dual-source scanner (SOMATOM Definition Flash, Siemens Medical Solutions, Germany). The following scan parameters were used: 320 mAs per rotation, 100 and 120 kV, pitch 3.4 for prospectively ECG-triggered high-pitch CTCA, scan range of 13.5 cm, collimation 64 × 2 × 0.6 mm with z-flying focal spot, gantry rotation time 280 ms, and simulated heart rate of 60 beats per minute. Results. Depending on the applied tube potential, the effective whole-body dose of the cardiac scan ranged from 1.1 mSv to 1.6 mSv and from 1.2 to 1.8 mSv for males and females, respectively. The radiosensitive breast tissue in the range of the primary beam caused an increased female-specific effective dose of 8.6%±0.3% compared to males. Decreasing the tube potential, a significant reduction of the effective dose of 35.8% and 36.0% can be achieved for males and females, respectively (P < 0.001). Conclusion. The radiologist and the CT technician should be aware of this new dose-saving strategy to keep the radiation exposure as low as reasonablly achievable.

  14. Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment

    PubMed Central

    Pjontek, Rastislav; Önenköprülü, Belgin; Scholz, Bernhard; Kyriakou, Yiannis; Schubert, Gerrit A; Othman, Ahmed; Wiesmann, Martin; Brockmann, Marc A

    2016-01-01

    Background Flat panel detector CT angiography with intravenous contrast agent injection (IV CTA) allows high-resolution imaging of cerebrovascular structures. Artifacts caused by metallic implants like platinum coils or clips lead to degradation of image quality and are a significant problem. Objective To evaluate the influence of a prototype metal artifact reduction (MAR) algorithm on image quality in patients with intracranial metallic implants. Methods Flat panel detector CT after intravenous application of 80 mL contrast agent was performed with an angiography system (Artis zee; Siemens, Forchheim, Germany) using a 20 s rotation protocol (200° rotation angle, 20 s acquisition time, 496 projections). The data before and after MAR of 26 patients with a total of 34 implants (coils, clips, stents) were independently evaluated by two blinded neuroradiologists. Results MAR improved the assessability of the brain parenchyma and small vessels (diameter <1 mm) in the neighborhood of metallic implants and at a distance of 6 cm (p<0.001 each, Wilcoxon test). Furthermore, MAR significantly improved the assessability of parent vessel patency and potential aneurysm remnants (p<0.005 each, McNemar test). MAR, however, did not improve assessability of stented vessels. Conclusions When an intravenous contrast protocol is used, MAR significantly ameliorates the assessability of brain parenchyma, vessels, and treated aneurysms in patients with intracranial coils or clips. PMID:26346458

  15. [New intensifying screens in clinical radiology. II. Examinations in clinical practice].

    PubMed

    Freyschmidt, J; Saure, D; Hagemann, G

    1976-09-01

    A clinically applicable procedure for testing new intensifying rare earth screens, as well as the special Siemens' screen is described. The results are related to universal screens. The film-screen combination alpha 4XD (gadolinium oxysulphide with normal, green sensitive film) results in a reduction of radiation dose to half with detail comparable with universal screens. The Siemens' special screen has similar advantages. Screens with a higher intensification factor and reduction of the mAs to one sixth results in loss of detail. This does not necessarily reduce their clinical use if they are used for appropriate purposes. The results of this clinically orientated technique agreed well with physically objective methods using lead grids. The advantages of the new screens are discussed in terms of their practical application.

  16. Determination of the precision error of the pulmonary artery thermodilution catheter using an in vitro continuous flow test rig.

    PubMed

    Yang, Xiao-Xing; Critchley, Lester A; Joynt, Gavin M

    2011-01-01

    Thermodilution cardiac output using a pulmonary artery catheter is the reference method against which all new methods of cardiac output measurement are judged. However, thermodilution lacks precision and has a quoted precision error of ± 20%. There is uncertainty about its true precision and this causes difficulty when validating new cardiac output technology. Our aim in this investigation was to determine the current precision error of thermodilution measurements. A test rig through which water circulated at different constant rates with ports to insert catheters into a flow chamber was assembled. Flow rate was measured by an externally placed transonic flowprobe and meter. The meter was calibrated by timed filling of a cylinder. Arrow and Edwards 7Fr thermodilution catheters, connected to a Siemens SC9000 cardiac output monitor, were tested. Thermodilution readings were made by injecting 5 mL of ice-cold water. Precision error was divided into random and systematic components, which were determined separately. Between-readings (random) variability was determined for each catheter by taking sets of 10 readings at different flow rates. Coefficient of variation (CV) was calculated for each set and averaged. Between-catheter systems (systematic) variability was derived by plotting calibration lines for sets of catheters. Slopes were used to estimate the systematic component. Performances of 3 cardiac output monitors were compared: Siemens SC9000, Siemens Sirecust 1261, and Philips MP50. Five Arrow and 5 Edwards catheters were tested using the Siemens SC9000 monitor. Flow rates between 0.7 and 7.0 L/min were studied. The CV (random error) for Arrow was 5.4% and for Edwards was 4.8%. The random precision error was ± 10.0% (95% confidence limits). CV (systematic error) was 5.8% and 6.0%, respectively. The systematic precision error was ± 11.6%. The total precision error of a single thermodilution reading was ± 15.3% and ± 13.0% for triplicate readings. Precision error increased by 45% when using the Sirecust monitor and 100% when using the Philips monitor. In vitro testing of pulmonary artery catheters enabled us to measure both the random and systematic error components of thermodilution cardiac output measurement, and thus calculate the precision error. Using the Siemens monitor, we established a precision error of ± 15.3% for single and ± 13.0% for triplicate reading, which was similar to the previous estimate of ± 20%. However, this precision error was significantly worsened by using the Sirecust and Philips monitors. Clinicians should recognize that the precision error of thermodilution cardiac output is dependent on the selection of catheter and monitor model.

  17. Concentrating Solar Power Projects - Olivenza 1 | Concentrating Solar Power

    Science.gov Websites

    Manufacturer: Siemens Turbine Description: 5 extractions Output Type: Steam Rankine Power Cycle Pressure: 100.0 bar Cooling Method: Wet cooling Cooling Method Description: Cooling Towers

  18. TESSIM: a simulator for the Athena-X-IFU

    NASA Astrophysics Data System (ADS)

    Wilms, J.; Smith, S. J.; Peille, P.; Ceballos, M. T.; Cobo, B.; Dauser, T.; Brand, T.; den Hartog, R. H.; Bandler, S. R.; de Plaa, J.; den Herder, J.-W. A.

    2016-07-01

    We present the design of tessim, a simulator for the physics of transition edge sensors developed in the framework of the Athena end to end simulation effort. Designed to represent the general behavior of transition edge sensors and to provide input for engineering and science studies for Athena, tessim implements a numerical solution of the linearized equations describing these devices. The simulation includes a model for the relevant noise sources and several implementations of possible trigger algorithms. Input and output of the software are standard FITS- files which can be visualized and processed using standard X-ray astronomical tool packages. Tessim is freely available as part of the SIXTE package (http://www.sternwarte.uni-erlangen.de/research/sixte/).

  19. TESSIM: A Simulator for the Athena-X-IFU

    NASA Technical Reports Server (NTRS)

    Wilms, J.; Smith, S. J.; Peille, P.; Ceballos, M. T.; Cobo, B.; Dauser, T.; Brand, T.; Den Hartog, R. H.; Bandler, S. R.; De Plaa, J.; hide

    2016-01-01

    We present the design of tessim, a simulator for the physics of transition edge sensors developed in the framework of the Athena end to end simulation effort. Designed to represent the general behavior of transition edge sensors and to provide input for engineering and science studies for Athena, tessim implements a numerical solution of the linearized equations describing these devices. The simulation includes a model for the relevant noise sources and several implementations of possible trigger algorithms. Input and output of the software are standard FITS-les which can be visualized and processed using standard X-ray astronomical tool packages. Tessim is freely available as part of the SIXTE package (http:www.sternwarte.uni-erlangen.deresearchsixte).

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valenti, M.

    This paper reports that as tougher emissions standards take hold throughout the industrialized world, manufacturers such as GE, Siemens, Foster Wheeler, and Asea Brown Boveri are designing advanced combined-cycle equipment that offers improved environmental performance without sacrificing power efficiency.

  1. Design of monitoring system for mail-sorting based on the Profibus S7 series PLC

    NASA Astrophysics Data System (ADS)

    Zhang, W.; Jia, S. H.; Wang, Y. H.; Liu, H.; Tang, G. C.

    2017-01-01

    With the rapid development of the postal express, the workload of mail sorting is increasing, but the automatic technology of mail sorting is not mature enough. In view of this, the system uses Siemens S7-300 PLC as the main station controller, PLC of Siemens S7-200/400 is from the station controller, through the man-machine interface configuration software MCGS, PROFIBUS-DP communication, RFID technology and mechanical sorting hand achieve mail classification sorting monitoring. Among them, distinguish mail-sorting by scanning RFID posted in the mail electronic bar code (fixed code), the system uses the corresponding controller on the acquisition of information processing, the processed information transmit to the sorting manipulator by PROFIBUS-DP. The system can realize accurate and efficient mail sorting, which will promote the development of mail sorting technology.

  2. Characterization of linear accelerator X-ray source size using a laminated beam-spot camera.

    PubMed

    Yeboah, Collins

    2011-05-10

    A laminated beam-spot camera of length 20 cm and effective cross-sectional area 2.5 cm × 3 cm was designed and constructed for the measurement of X-ray beam-spot sizes on different models of Siemens accelerators. With the accelerator gantry at 180° and camera positioned on an accessory tray holder, an XV film placed in contact with the camera at the distal end of it detected those X-rays that were transmitted through the camera. The FWHM of the detected X-ray intensity profile in the gun-target (G-T) direction or the orthogonal A-B direction was used as a measure of the beam-spot size in that direction. Siemens Mevatron MXEs exhibited a beam-spot size of 1.7 ± 0.2 mm in both the in-plane and cross-plane directions for 6 MV photon beams. The beam-spot size observed for a Mevatron MDX-2 was larger by up to 1 mm, and also was different for the in-plane and cross-plane directions. For Siemens PRIMUS accelerators, the beam-spot size in the in-plane direction was found to fall in the range 2.0-2.2 ± 0.2 mm, whereas the beam-spot size in the cross-plane direction fell within 1.7-1.9 ± 0.2 mm for 6, 10, and 18 MV photon beams. Assessment of long-term stability of the beam-spot size shows the spot size remains fairly stable over time.

  3. Transforming an industrial giant. Interview by Thomas A. Stewart and Louise O'Brien.

    PubMed

    von Pierer, Heinrich

    2005-02-01

    In his 12 years at the helm of Siemens, CEO Heinrich von Pierer designed and directed a major transformation. Taking this German icon from a technically superb but slow-moving industrial giantto a disciplined yet nimble multinational has posed enormous challenges. Since 1992, Siemens has revamped its portfolio of businesses, expanded its reach into 192 countries, and created a more local-market-driven culture, gaining recognition as one of the best-managed and most competitive companies in the world. In this edited interview with HBR editor Thomas A. Stewart and consulting editor Louise O'Brien, von Pierer describes the requirements for transformation and culture change and how he broke down historical barriers at Siemens. He shares his insights about portfolio restructuring, his lessons from competing with GE, and the pros and cons of being based in Europe versus America. He reflects on the true start of globalization after the fall of the Berlin wall and on how dramatically the company needed to change in order to counter the resulting pricing pressures across all of its businesses. He talks, too, about the biggest challenge on his successor's desk-"the particular challenge of China;" he says. Amid all these topics, von Pierer reiterates the importance of people: "We all talk about people as our most important resource, but as a matter of fact, who's really taking care of people?... We need [their] backing. We can't afford to run into a situation where people no longer accept what we do."

  4. Predictive Factors for Visual Field Conversion: Comparison of Scanning Laser Polarimetry and Optical Coherence Tomography.

    PubMed

    Diekmann, Theresa; Schrems-Hoesl, Laura M; Mardin, Christian Y; Laemmer, Robert; Horn, Folkert K; Kruse, Friedrich E; Schrems, Wolfgang A

    2018-02-01

    The purpose of this study was to compare the ability of scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (SD-OCT) to predict future visual field conversion of subjects with ocular hypertension and early glaucoma. All patients were recruited from the Erlangen glaucoma registry and examined using standard automated perimetry, 24-hour intraocular pressure profile, and optic disc photography. Peripapillary retinal nerve fiber layer thickness (RNFL) measurements were obtained by SLP (GDx-VCC) and SD-OCT (Spectralis OCT). Positive and negative predictive values (PPV, NPV) were calculated for morphologic parameters of SLP and SD-OCT. Kaplan-Meier survival curves were plotted and log-rank tests were performed to compare the survival distributions. Contingency tables and Venn-diagrams were calculated to compare the predictive ability. The study included 207 patients-75 with ocular hypertension, 85 with early glaucoma, and 47 controls. Median follow-up was 4.5 years. A total of 29 patients (14.0%) developed visual field conversion during follow-up. SLP temporal-inferior RNFL [0.667; 95% confidence interval (CI), 0.281-0.935] and SD-OCT temporal-inferior RNFL (0.571; 95% CI, 0.317-0.802) achieved the highest PPV; nerve fiber indicator (0.923; 95% CI, 0.876-0.957) and SD-OCT mean (0.898; 95% CI, 0.847-0.937) achieved the highest NPV of all investigated parameters. The Kaplan-Meier curves confirmed significantly higher survival for subjects within normal limits of measurements of both devices (P<0.001). Venn diagrams tested with McNemar test statistics showed no significant difference for PPV (P=0.219) or NPV (P=0.678). Both GDx-VCC and SD-OCT demonstrate comparable results in predicting future visual field conversion if taking typical scans for GDx-VCC. In addition, the likelihood ratios suggest that GDx-VCC's nerve fiber indicator<30 may be the most useful parameter to confirm future nonconversion. (http://www.ClinicalTrials.gov number, NTC00494923; Erlangen Glaucoma Registry).

  5. Rapid Assessment of the Viability of Mycobacterium avium subsp. paratuberculosis Cells after Heat Treatment, Using an Optimized Phage Amplification Assay▿

    PubMed Central

    Foddai, Antonio; Elliott, Christopher T.; Grant, Irene R.

    2010-01-01

    Thermal inactivation experiments were carried out to assess the utility of a recently optimized phage amplification assay to accurately enumerate viable Mycobacterium avium subsp. paratuberculosis cells in milk. Ultra-heat-treated (UHT) whole milk was spiked with large numbers of M. avium subsp. paratuberculosis organisms (106 to 107 CFU/ml) and dispensed in 100-μl aliquots in thin-walled 200-μl PCR tubes. A Primus 96 advanced thermal cycler (Peqlab, Erlangen, Germany) was used to achieve the following time and temperature treatments: (i) 63°C for 3, 6, and 9 min; (ii) 68°C for 20, 40, and 60 s; and (iii) 72°C for 5, 10, 15, and 25 s. After thermal stress, the number of surviving M. avium subsp. paratuberculosis cells was assessed by both phage amplification assay and culture on Herrold's egg yolk medium (HEYM). A high correlation between PFU/ml and CFU/ml counts was observed for both unheated (r2 = 0.943) and heated (r2 = 0.971) M. avium subsp. paratuberculosis cells. D and z values obtained using the two types of counts were not significantly different (P > 0.05). The D68°C, mean D63°C, and D72°C for four M. avium subsp. paratuberculosis strains were 81.8, 9.8, and 4.2 s, respectively, yielding a mean z value of 6.9°C. Complete inactivation of 106 to 107 CFU of M. avium subsp. paratuberculosis/ml milk was not observed for any of the time-temperature combinations studied; 5.2- to 6.6-log10 reductions in numbers were achieved depending on the temperature and time. Nonlinear thermal inactivation kinetics were consistently observed for this bacterium. This study confirms that the optimized phage assay can be employed in place of conventional culture on HEYM to speed up the acquisition of results (48 h instead of a minimum of 6 weeks) for inactivation experiments involving M. avium subsp. paratuberculosis-spiked samples. PMID:20097817

  6. Objectifying user critique. A means of continuous quality assurance for physician discharge letter composition.

    PubMed

    Oschem, M; Mahler, V; Prokosch, H U

    2011-01-01

    The aim of this study is to objectify user critique rendering it usable for quality assurance. Based on formative and summative evaluation results we strive to promote software improvements; in our case, the physician discharge letter composition process at the Department of Dermatology, University Hospital Erlangen, Germany. We developed a novel six-step approach to objectify user critique: 1) acquisition of user critique using subjectivist methods, 2) creation of a workflow model, 3) definition of hypothesis and indicators, 4) measuring of indicators, 5) analyzing results, 6) optimization of the system regarding both subjectivist and objectivist evaluation results. In particular, we derived indicators and workflows directly from user critique/narratives. The identified indicators were mapped onto workflow activities, creating a link between user critique and the evaluated system. Users criticized a new discharge letter system as "too slow" and "too labor-intensive" in comparison with the previously used system. In a stepwise approach we collected subjective user critique, derived a comprehensive process model including deviations and deduced a set of five indicators for objectivist evaluation: processing time, system-related waiting time, number of mouse clicks, number of keyboard inputs, and throughput time. About 3500 measurements have been performed to compare the workflow-steps of both systems, regarding 20 discharge letters. Although the difference of the mean total processing time between both systems was statistically insignificant (2011.7 s vs. 1971.5 s; p = 0.457), we detected a significant difference in waiting times (101.8 s vs. 37.2 s; p <0.001) and number of user interactions (77 vs. 69; p <0.001) in favor of the old system, thus objectifying user critique. Our six-step approach enables objectification of user critique, resulting in objective values for continuous quality assurance. To our knowledge no previous study in medical informatics mapped user critique onto workflow steps. Subjectivist analysis prompted us to use the indicator system-related waiting time for the objectivist study, which was rarely done before. We consider combining subjectivist and objectivist methods as a key point of our approach. Future work will concentrate on automated measurement of indicators.

  7. Topography-guided treatment of irregular astigmatism with the wavelight excimer laser.

    PubMed

    Jankov, Mirko R; Panagopoulou, Sophia I; Tsiklis, Nikolaos S; Hajitanasis, Georgos C; Aslanides, loannis M; Pallikaris, loannis G

    2006-04-01

    To evaluate the feasibility, safety, and predictability of correcting high irregular astigmatism in symptomatic eyes with the use of topography-guided photoablation. In a prospective, non-comparative case series, 16 consecutive symptomatic eyes of 11 patients with small hyperopic and myopic excimer laser optical zones, decentered and irregular ablation after corneal graft, and corneal scars were operated. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest and cycloplegic refraction, and corneal topography, with asphericity and regularity, were analyzed. LASIK (n = 10) and photorefractive keratectomy (n = 6) were performed using the ALLEGRETTO WAVE excimer laser and T-CAT software (Topography-guided Customized Ablation Treatment; WaveLight Laser Technologie AG, Erlangen, Germany). In the LASIK group, UCVA improved from 0.81 +/- 0.68 IogMAR (20/130) (range: 0.2 to 2.0) to 0.29 +/- 0.21 logMAR (20/39) (range: 0.1 to 0.7) at 6 months. In the PRK group, mean UCVA improved from 0.89 +/- 0.87 IogMAR (20/157) (range: 0.1 to 2.0) to 0.42 +/- 0.35 logMAR (20/53) (range: 0.1 to 1.0) at 6 months. Best spectacle-corrected visual acuity did not change significantly in either group. One PRK patient lost one line of BSCVA. Refractive cylinder for the LASIK group improved from -2.53 +/- 1.71 diopters (D) (range: -0.75 to -5.75 D) to -1.28 +/- 0.99 D (range: 0 to -2.50 D) at 6 months. Refractive cylinder in the PRK group improved from -2.21 +/- 2.11 D (range: -0.25 to -5.50 D) to -1.10 +/- 0.42 D (range: -0.50 to -1.50 D). Index of surface irregularity showed a decrease from 60 +/- 12 (range: 46 to 89) to 50 +/- 9 (range: 32 to 63) at 6 months in the LASIK group whereas no significant change was noted in the PRK group. Subjective symptoms, such as glare, halos, ghost images, starbursts, and monocular diplopia, were not present postoperatively. Topography-guided LASIK and PRK resulted in a significant reduction of refractive cylinder and increase of UCVA, without a significant loss of BSCVA.

  8. Innovation Concepts in Healthcare

    ScienceCinema

    Requardt, Hermann

    2017-12-18

    Demographic change and advances in medical science pose increased challenges to healthcare systems globally: The economic basis is aging and thus health is becoming more and more a productivity factor. At the same time, with today’s new communication possibilities the demand and expectations of effective medical treatment have been increased. This presentation will illustrate the need for the “industrialization” of healthcare in order to achieve highest results at limited budgets. Thereby, industrialization is not meaning the medical treatment based on the assembly line approach. Rather it is to recognize the cost of medical care as an investment with respective expectations on the return of the investment. Innovations in imaging and pharmaceutical products as well as in processes - that lead to similar medical results, but with lower efforts - are keys in such scenarios. Biography Prof. Dr. Hermann Requardt, 54, is a member of the Managing Board of Siemens AG and Chief Executive Officer of the Healthcare Sector. In addition he is the CTO of Siemens AG and Head of Corporate Technology, the central research department at Siemens. After completing his studies in physics and philosophy at the Darmstadt University of Technology and Johann Wolfgang Goethe University in Frankfurt and receiving a doctorate in biophysics, he worked at the Institute of Aerospace Medicine at the German Aerospace Center.In 1984 he joined the Medical Technology Group of Siemens AG, where he was responsible for projects in the Magnetic Resonance (MR) division. He was appointed head of the division in 1995. From 2001 to 2006, as a member of the Executive Management of the Medical Solutions Group, he was responsible for several areas, including technological development.In 2006 he became a Member of the Siemens’ Managing Board and head of Corporate Technology. He was additionally appointed as the Sector Healthcare CEO in 2008.Since 2006 he is an honorary professor in physics of the Johann Wolfgang Goethe University in Frankfurt.                                                                                

  9. Autovalidation and automation of the postanalytical phase of routine hematology and coagulation analyses in a university hospital laboratory.

    PubMed

    Mlinaric, Ana; Milos, Marija; Coen Herak, Désirée; Fucek, Mirjana; Rimac, Vladimira; Zadro, Renata; Rogic, Dunja

    2018-02-23

    The need to satisfy high-throughput demands for laboratory tests continues to be a challenge. Therefore, we aimed to automate postanalytical phase in hematology and coagulation laboratory by autovalidation of complete blood count (CBC) and routine coagulation test results (prothrombin time [PT], international normalized ratio [PT-INR], activated partial thromboplastin time [APTT], fibrinogen, antithrombin activity [AT] and thrombin time [TT]). Work efficacy and turnaround time (TAT) before and after implementation of automated solutions will be compared. Ordering panels tailored to specific patient populations were implemented. Rerun and reflex testing rules were set in the respective analyzers' software (Coulter DxH Connectivity 1601, Beckman Coulter, FL, USA; AutoAssistant, Siemens Healthcare Diagnostics, Germany), and sample status information was transferred into the laboratory information system. To evaluate if the automation improved TAT and efficacy, data from manually verified results in September and October of 2015 were compared with the corresponding period in 2016 when autovalidation was implemented. Autovalidation rates of 63% for CBC and 65% for routine coagulation test results were achieved. At the TAT of 120 min, the percentage of reported results increased substantially for all analyzed tests, being above 90% for CBC, PT, PT-INR and fibrinogen and 89% for APTT. This output was achieved with three laboratory technicians less compared with the period when the postanalytical phase was not automated. Automation allowed optimized laboratory workflow for specific patient populations, thereby ensuring standardized results reporting. Autovalidation of test results proved to be an efficient tool for improvement of laboratory work efficacy and TAT.

  10. Estimation of radiation cancer risk in CT-KUB

    NASA Astrophysics Data System (ADS)

    Karim, M. K. A.; Hashim, S.; Bakar, K. A.; Bradley, D. A.; Ang, W. C.; Bahrudin, N. A.; Mhareb, M. H. A.

    2017-08-01

    The increased demand for computed tomography (CT) in radiological scanning examinations raises the question of a potential health impact from the associated radiation exposures. Focusing on CT kidney-ureter-bladder (CT-KUB) procedures, this work was aimed at determining organ equivalent dose using a commercial CT dose calculator and providing an estimate of cancer risks. The study, which included 64 patients (32 males and 32 females, mean age 55.5 years and age range 30-80 years), involved use of a calibrated CT scanner (Siemens-Somatom Emotion 16-slice). The CT exposures parameter including tube potential, pitch factor, tube current, volume CT dose index (CTDIvol) and dose-length product (DLP) were recorded and analyzed using CT-EXPO (Version 2.3.1, Germany). Patient organ doses, including for stomach, liver, colon, bladder, red bone marrow, prostate and ovaries were calculated and converted into cancer risks using age- and sex-specific data published in the Biological Effects of Ionizing Radiation (BEIR) VII report. With a median value scan range of 36.1 cm, the CTDIvol, DLP, and effective dose were found to be 10.7 mGy, 390.3 mGy cm and 6.2 mSv, respectively. The mean cancer risks for males and females were estimated to be respectively 25 and 46 out of 100,000 procedures with effective doses between 4.2 mSv and 10.1 mSv. Given the increased cancer risks from current CT-KUB procedures compared to conventional examinations, we propose that the low dose protocols for unenhanced CT procedures be taken into consideration before establishing imaging protocols for CT-KUB.

  11. MR Imaging with Metal-suppression Sequences for Evaluation of Total Joint Arthroplasty.

    PubMed

    Talbot, Brett S; Weinberg, Eric P

    2016-01-01

    Metallic artifact at orthopedic magnetic resonance (MR) imaging continues to be an important problem, particularly in the realm of total joint arthroplasty. Complications often follow total joint arthroplasty and can be expected for a small percentage of all implanted devices. Postoperative complications involve not only osseous structures but also adjacent soft tissues-a highly problematic area at MR imaging because of artifacts from metallic prostheses. Without special considerations, susceptibility artifacts from ferromagnetic implants can unacceptably degrade image quality. Common artifacts include in-plane distortions (signal loss and signal pileup), poor or absent fat suppression, geometric distortion, and through-section distortion. Basic methods to reduce metallic artifacts include use of spin-echo or fast spin-echo sequences with long echo train lengths, short inversion time inversion-recovery (STIR) sequences for fat suppression, a high bandwidth, thin section selection, and an increased matrix. With care and attention to the alloy type (eg, titanium, cobalt-chromium, stainless steel), orientation of the implant, and magnetic field strength, as well as use of proprietary and nonproprietary metal-suppression techniques, previously nondiagnostic studies can yield key diagnostic information. Specifically, sequences such as the metal artifact reduction sequence (MARS), WARP (Siemens Healthcare, Munich, Germany), slice encoding for metal artifact correction (SEMAC), and multiacquisition with variable-resonance image combination (MAVRIC) can be optimized to reveal pathologic conditions previously hidden by periprosthetic artifacts. Complications of total joint arthroplasty that can be evaluated by using MR imaging with metal-suppression sequences include pseudotumoral conditions such as metallosis and particle disease, infection, aseptic prosthesis loosening, tendon injury, and muscle injury. ©RSNA, 2015.

  12. Ventricular strain changes in monochorionic twins with and without twin-to-twin transfusion syndrome.

    PubMed

    Taylor-Clarke, Marisa C; Matsui, Hikoro; Roughton, Michael; Wimalasundera, Ruwan C; Gardiner, Helena M

    2013-06-01

    The objective of the study was to investigate whether vector velocity imaging (VVI), a non-Doppler speckle tracking ultrasound technology, is feasible in twin pregnancies and can aid management of twin-twin transfusion syndrome (TTTS). Twenty-seven women pregnant with monochorionic diamniotic twins affected by TTTS and 28 monochorionic pregnancies that did not develop TTTS were included in a prospective case-control study at a fetal medicine center. Fetal echocardiograms were recorded with dummy electrocardiography to retain original frame rates when exported for offline speckle tracking analysis using Syngo-VVI software (Siemens Corp, Munich, Germany). Right and left ventricular (LV) free wall Lagrangian strain was measured from the original coordinates. Within-twin pair ventricular strain differences including relationship to Quintero staging and response to laser therapy for TTTS were analyzed by Wilcoxon signed-rank test. The VVI strain measurements could be analyzed in 182 of 200 TTTS and 96 of 112 non-TTTS control ventricles. Within-pair strain was concordant in non-TTTS controls. Recipient LV strain was reduced at all Quintero stages compared with donors (P < .01). Recipient right ventricular strain was reduced only in stages 3 and 4 (P < .01). Strain improved at a median of 2 weeks following successful laser therapy. Intertwin differences in strain were independent of weight discordance. Recipient LV strain is reduced in stages 1 and 2 TTTS. Within-pair strain discordance may distinguish early TTTS from growth discordance and guide timing of and management following treatment. Copyright © 2013 Mosby, Inc. All rights reserved.

  13. Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment.

    PubMed

    Pjontek, Rastislav; Önenköprülü, Belgin; Scholz, Bernhard; Kyriakou, Yiannis; Schubert, Gerrit A; Nikoubashman, Omid; Othman, Ahmed; Wiesmann, Martin; Brockmann, Marc A

    2016-08-01

    Flat panel detector CT angiography with intravenous contrast agent injection (IV CTA) allows high-resolution imaging of cerebrovascular structures. Artifacts caused by metallic implants like platinum coils or clips lead to degradation of image quality and are a significant problem. To evaluate the influence of a prototype metal artifact reduction (MAR) algorithm on image quality in patients with intracranial metallic implants. Flat panel detector CT after intravenous application of 80 mL contrast agent was performed with an angiography system (Artis zee; Siemens, Forchheim, Germany) using a 20 s rotation protocol (200° rotation angle, 20 s acquisition time, 496 projections). The data before and after MAR of 26 patients with a total of 34 implants (coils, clips, stents) were independently evaluated by two blinded neuroradiologists. MAR improved the assessability of the brain parenchyma and small vessels (diameter <1 mm) in the neighborhood of metallic implants and at a distance of 6 cm (p<0.001 each, Wilcoxon test). Furthermore, MAR significantly improved the assessability of parent vessel patency and potential aneurysm remnants (p<0.005 each, McNemar test). MAR, however, did not improve assessability of stented vessels. When an intravenous contrast protocol is used, MAR significantly ameliorates the assessability of brain parenchyma, vessels, and treated aneurysms in patients with intracranial coils or clips. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Activated protein C resistance in patients following venous thromboembolism receiving rivaroxaban versus vitamin K antagonists: assessment using Russell viper venom time-based assay.

    PubMed

    Goralczyk, Tadeusz; Wojtowicz, Katarzyna B; Undas, Anetta

    2017-06-01

    : Activated protein C resistance (APC-R) is assessed as part of thrombophilia screening, preferably in patients not taking oral anticoagulants. Rivaroxaban is known to alter some APC-R assays. To our knowledge, there have been no reports on the effect of rivaroxaban on the Russell viper venom time (RVVT)-based APC-R assay in real-life patients. In 168 consecutive outpatients suspected of having venous thromboembolism because of thrombophilia, APC-R was determined using the RVVT-based ProC Ac R assay (Siemens, Marburg, Germany). Patients receiving rivaroxaban or vitamin K antagonists were eligible. We measured rivaroxaban concentrations using the anti-Xa Biophen DiXal assay (Hyphen Biomed, Neuville-Sur-Oise, France) and factor V Leiden using the real-time PCR. APC-R was detected in 23 (28%) patients on rivaroxaban (n = 81) administrated 2-48 h since the blood draw, 15 (28%) patients on vitamin K antagonists (n = 54), and in four (12%) patients off anticoagulation (n = 33). Compared with nonanticoagulated patients, APC-R ratios were similar in patients on rivaroxaban, without any correlation with rivaroxaban concentrations (from 0 to 303 μg/l). None of the patients on rivaroxaban were found to have false-negative or false-positive APC-R ratios. Rivaroxaban concentrations up to 300 μg/l do not affect results of the ProC Ac R RVVT-based assay, which could be recommended in patients referred to a clinic for thrombophilia screening in whom the time since the last dose of rivaroxaban is uncertain.

  15. 75 FR 12175 - Application(s) for Duty-Free Entry of Scientific Instruments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-15

    ..., 1301 Beal Avenue, Ann Arbor, MI 49109-2122. Instrument: Tester for TFT Imager. Manufacturer: Siemens AG... capability of amorphous silicon TFT and organic photo-diode. This instrument must be capable of measuring...

  16. West Europe Report.

    DTIC Science & Technology

    1986-05-23

    Kraftwerk Union Power Plant... DER SPIEGEL: ...a 100-percent Siemens daughter enterprise... Kaske: ...to companies which are participating in the...major competitor, Kraftwerk Union AG (KWU) at Muelheim on the Ruhr, with its mass-produced light-water reactors. The High Temperature Reactor

  17. Monte Carlo modeling of the Siemens Optifocus multileaf collimator.

    PubMed

    Laliena, Victor; García-Romero, Alejandro

    2015-05-01

    We have developed a new component module for the BEAMnrc software package, called SMLC, which models the tongue-and-groove structure of the Siemens Optifocus multileaf collimator. The ultimate goal is to perform accurate Monte Carlo simulations of the IMRT treatments carried out with Optifocus. SMLC has been validated by direct geometry checks and by comparing quantitatively the results of simulations performed with it and with the component module VARMLC. Measurements and Monte Carlo simulations of absorbed dose distributions of radiation fields sensitive to the tongue-and-groove effect have been performed to tune the free parameters of SMLC. The measurements cannot be accurately reproduced with VARMLC. Finally, simulations of a typical IMRT field showed that SMLC improves the agreement with experimental measurements with respect to VARMLC in clinically relevant cases. 87.55. K. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. [Evaluation of DCA vantage for rapid in-clinic measurement of HbA1c on capillary blood in young type 1 diabetic patients].

    PubMed

    El Arabi, H; Willems, D; Mélot, C; Dorchy, H

    2013-01-01

    Rapid in clinic measurement of glycated hemoglogin (HbA1c) allows to determine the level of metabolic control within a few minutes on capillary blood. We have evaluated the new DCA Vantage (Siemens) based on an immunological technique, replacing the DCA 2000+ (Siemens). The study included 120 unselected young type 1 diabetic patients, with different degrees of metabolic control. The DCA Vantage was compared with the HPLC system (Menarini HA 8160) whose deviation from the DCCT was < 0.1% across the clinical range. The mean underestimation of the DCA Vantage was -0.40%. The agreement limits (+/- 1.96 SD) were between 0.14% and -0.93%; this means +/- 0.53% around -0.40%. In conclusion, the DCA Vantage underestimates HbA1c levels; however it met the acceptance criteria of having a coefficient of variation < 3%.

  19. Clinical validation of an in-house EPID dosimetry system for IMRT QA at the Prince of Wales Hospital

    NASA Astrophysics Data System (ADS)

    Tyler, M.; Vial, P.; Metcalfe, P.; Downes, S.

    2013-06-01

    In this study a simple method using standard flood-field corrected Electronic Portal Imaging Device (EPID) images for routine Intensity Modulated Radiation Therapy (IMRT) Quality Assurance (QA) was investigated. The EPID QA system was designed and tested on a Siemens Oncor Impression linear accelerator with an OptiVue 1000ST EPID panel (Siemens Medical Solutions USA, Inc, USA) and an Elekta Axesse linear accelerator with an iViewGT EPID (Elekta AB, Sweden) for 6 and 10 MV IMRT fields with Step-and-Shoot and dynamic-MLC delivery. Two different planning systems were used for patient IMRT field generation for comparison with the measured EPID fluences. All measured IMRT plans had >95% agreement to the planning fluences (using 3 cGy / 3 mm Gamma Criteria) and were comparable to the pass-rates calculated using a 2-D diode array dosimeter.

  20. Improvements in Cz silicon PV module manufacturing

    NASA Astrophysics Data System (ADS)

    King, Richard R.; Mitchell, Kim W.; Jester, Theresa L.

    1997-02-01

    Work focused on reducing the cost per watt of Cz Si photovoltaic modules under Phase I of Siemens Solar Industries' DOE/NREL PVMaT 4A subcontract is described. Module cost components are analyzed and solutions to high-cost items are discussed in terms of specific module designs. The approaches of using larger cells and modules to reduce per-part processing cost, and of minimizing yield loss are particularly leveraging. Yield components for various parts of the fabrication process and various types of defects are shown, and measurements of the force required to break wafers throughout the cell fabrication sequence are given. The most significant type of yield loss is mechanical breakage. The implementation of statistical process control on key manufacturing processes at Siemens Solar Industries is described. Module configurations prototyped during Phase I of this project and scheduled to begin production in Phase II have a projected cost per watt reduction of 19%.

  1. Comparative Study of 28 and 18 Years Field Aged Siemens-Arco M55 Modules in Temperate and Hot-Dry Climates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chicca, Matthew; Wohlgemuth, John; TamizhMani, GovindaSamy

    The primary objective of this research work is two-fold: (i) determine the degradation rates of Siemens-Arco M55 modules exposed over 18 and 28 years in a hot-dry climate of Arizona and a temperate climate of California, and; (ii) identify the potential modes responsible for these degradation losses. The degradation rates were determined based on the I-V data obtained on exposed modules and on the corresponding control modules which were not exposed in the fields. The degradation modes responsible for these degradations were determined using several nondestructive tests and destructive tests performed on these control and exposed modules. The nondestructive testsmore » included: current-voltage, visual inspection, cell-module quantum efficiency, and module level reflectance spectroscopy. The destructive tests included: transmittance spectroscopy of glass superstrates, and FTIR, DSC and TGA of encapsulant materials.« less

  2. The four medical theses of Samuel Hahnemann (1755-1843).

    PubMed

    Lang, Christoph Jg

    2016-05-01

    Samuel Hahnemann, the founder of homoeopathy, over a period of 33 years wrote four medical theses at three different universities. The first, in 1779 at the University of Erlangen, Franconia, dealt with agents that allegedly induce spasms, granting him a MD degree. The second two theses in 1784 dealt with obstetrical matters and were imposed upon him by the University of Wittenberg, Saxony, for becoming a medical officer, a position he apparently aspired to mostly for financial reasons. The fourth thesis in 1812 at the University of Leipzig, Saxony, his most elaborate dissertation on a toxic plant, white hellebore, served as a habilitation, allowing him to hold university lectures in order to disseminate his new ideas. © The Author(s) 2014.

  3. ["Treating mankind honestly": medical innovation between market, public and science around 1800].

    PubMed

    Hess, Volker

    2006-01-01

    This contribution is based on a case study of Professor Gottfried Christian Reich (1769-1848) of Erlangen, who in 1799 published what he considered to be an infallible method of curing any illness associated with a fever. This paper shows how in the course of a published debate the focus shifted from a medico-scientific issue to a moral one. Furthermore, the experiments carried out at Berlin's Charité hospital by order of the Prussian Medical Authority illustrate how the public debate had an effect on the assessment of the empirical evidence produced. Overall, this case study demonstrates that we can use the history of a medical innovation as a means to highlight the interconnections between medical science, the public, and the market.

  4. Baseline morning cortisol level as a predictor of pituitary-adrenal reserve: a comparison across three assays.

    PubMed

    Sbardella, Emilia; Isidori, Andrea M; Woods, Conor P; Argese, Nicola; Tomlinson, Jeremy W; Shine, Brian; Jafar-Mohammadi, Bahram; Grossman, Ashley B

    2017-02-01

    The short ACTH stimulation test (250 μg) is the dynamic test most frequently used to assess adrenal function. It is possible that a single basal cortisol could be used to predict the dynamic response, but research has been hampered by the use of different assays and thresholds. To propose a morning baseline cortisol criterion of three of the most commonly used modern cortisol immunoassays - Advia Centaur (Siemens), Architect (Abbott) and the Roche Modular System (Roche) - that could predict adrenal sufficiency. Observational, retrospective cross-sectional study at two centres. Retrospective analysis of the results of 1019 Short Synacthen tests (SSTs) with the Advia Centaur, 449 SSTs with the Architect and 2050 SSTs with the Roche Modular System assay. Serum cortisol levels were measured prior to injection of 250 μg Synacthen and after 30 min. Overall, we were able to collate data from a total of 3518 SSTs in 3571 patients. Using receiver-operator curve analysis, baseline cortisol levels for predicting passing the SST with 100% specificity were 358 nmol/l for Siemens, 336 nmol/l for Abbott and 506 nmol/l for Roche. Utilizing these criteria, 589, 158 and 578 SSTs, respectively, for Siemens, Abbott and Roche immunoassays could have been avoided. We have defined assay-specific morning cortisol levels that are able to predict the integrity of the hypothalamo-pituitary-adrenal axis. We propose that this represents a valid tool for the initial assessment of adrenal function and has the potential to obviate the need for dynamic testing in a significant number of patients. © 2016 John Wiley & Sons Ltd.

  5. Inter-vender and test-retest reliabilities of resting-state functional magnetic resonance imaging: Implications for multi-center imaging studies.

    PubMed

    An, Hyeong Su; Moon, Won-Jin; Ryu, Jae-Kyun; Park, Ju Yeon; Yun, Won Sung; Choi, Jin Woo; Jahng, Geon-Ho; Park, Jang-Yeon

    2017-12-01

    This prospective multi-center study aimed to evaluate the inter-vendor and test-retest reliabilities of resting-state functional magnetic resonance imaging (RS-fMRI) by assessing the temporal signal-to-noise ratio (tSNR) and functional connectivity. Study included 10 healthy subjects and each subject was scanned using three 3T MR scanners (GE Signa HDxt, Siemens Skyra, and Philips Achieva) in two sessions. The tSNR was calculated from the time course data. Inter-vendor and test-retest reliabilities were assessed with intra-class correlation coefficients (ICCs) derived from variant component analysis. Independent component analysis was performed to identify the connectivity of the default-mode network (DMN). In result, the tSNR for the DMN was not significantly different among the GE, Philips, and Siemens scanners (P=0.638). In terms of vendor differences, the inter-vendor reliability was good (ICC=0.774). Regarding the test-retest reliability, the GE scanner showed excellent correlation (ICC=0.961), while the Philips (ICC=0.671) and Siemens (ICC=0.726) scanners showed relatively good correlation. The DMN pattern of the subjects between the two sessions for each scanner and between three scanners showed the identical patterns of functional connectivity. The inter-vendor and test-retest reliabilities of RS-fMRI using different 3T MR scanners are good. Thus, we suggest that RS-fMRI could be used in multicenter imaging studies as a reliable imaging marker. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Comparison of lung sound transducers using a bioacoustic transducer testing system.

    PubMed

    Kraman, Steve S; Wodicka, George R; Pressler, Gary A; Pasterkamp, Hans

    2006-08-01

    Sensors used for lung sound research are generally designed by the investigators or adapted from devices used in related fields. Their relative characteristics have never been defined. We employed an artificial chest wall with a viscoelastic surface and a white noise signal generator as a stable source of sound to compare the frequency response and pulse waveform reproduction of a selection of devices used for lung sound research. We used spectral estimation techniques to determine frequency response and cross-correlation of pulses to determine pulse shape fidelity. The sensors evaluated were the Siemens EMT 25 C accelerometer (Siemens); PPG 201 accelerometer (PPG); Sony ECM-T150 electret condenser microphone with air coupler (air coupler; with cylindrical air chambers of 5-, 10-, and 15-mm diameter and conical air chamber of 10-mm diameter); Littman classic stethoscope head (Littman) connected to an electret condenser microphone; and the Andries Tek (Andries) electronic stethoscope. We found that the size and shape of the air coupler chamber to have no important effect on the detected sound. The Siemens, air coupler, and Littman performed similarly with relatively flat frequency responses from 200 to 1,200 Hz. The PPG had the broadest frequency response, with useful sensitivity extending to 4,000 Hz. The Andries' frequency response was the poorest above 1,000 Hz. Accuracy in reproducing pulses roughly corresponded with the high-frequency sensitivity of the sensors. We conclude that there are important differences among commonly used lung sound sensors that have to be defined to allow the comparison of data from different laboratories.

  7. Intensity-modulated radiation therapy (IMRT) with different combinations of treatment-planning systems and linacs: issues and how to detect them.

    PubMed

    Dobler, Barbara; Lorenz, Friedlieb; Wertz, Hansjörg; Polednik, Martin; Wolff, Dirk; Steil, Volker; Lohr, Frank; Wenz, Frederik

    2006-08-01

    To compare different combinations of intensity-modulated radiation therapy (IMRT) system components with regard to quality assurance (QA), especially robustness against malfunctions and dosimetry. Three different treatment-planning systems (TPS), two types of linacs and three multileaf collimator (MLC) types were compared: commissioning procedures were performed for the combination of the TPS Corvus 5.0 (Nomos) and KonRad v2.1.3 (Siemens OCS) with the linacs KD2 (Siemens) and Synergy (Elekta). For PrecisePLAN 2.03 (Elekta) measurements were performed for Elekta Synergy only. As record and verify (R&V) system Multi-Access v7 (IMPAC) was used. The use of the serial tomotherapy system Peacock (Nomos) was investigated in combination with the Siemens KD2 linac. In the comparison of calculated to measured dose, problems were encountered for the combination of KonRad and Elekta MLC as well as for the Peacock system. Multi-Access failed to assign the collimator angle correctly for plans with multiple collimator angles per beam. Communication problems of Multi-Access with both linacs were observed, resulting in incorrect recording of the treatment. All reported issues were addressed by the manufacturers. For the commissioning of IMRT systems, the whole chain from the TPS to the linac has to be investigated. Components that passed the commissioning in another clinical environment can have severe malfunctions when used in a new environment. Therefore, not only single components but the whole chain from planning to delivery has to be evaluated in commissioning and checked regularly for QA.

  8. Assessment of a Modified Acoustic Lens for Electromagnetic Shock Wave Lithotripters in a Swine Model

    PubMed Central

    Mancini, John G.; Neisius, Andreas; Smith, Nathan; Sankin, Georgy; Astroza, Gaston M.; Lipkin, Michael E.; Simmons, Walther N.; Preminger, Glenn M.; Zhong, Pei

    2013-01-01

    Purpose The acoustic lens of the Siemens Modularis electromagnetic (EM) shock wave lithotripter has been modified to produce a pressure waveform and focal zone more closely resembling that of the original Dornier HM3 device. Herein, we assess the newly designed acoustic lens in vivo in an animal model. Materials and Methods Stone fragmentation and tissue injury produced by the original and modified lenses of a Siemens lithotripter were evaluated in a swine model under equivalent acoustic pulse energy (~45 mJ) at 1 Hz pulse repetition frequency. Stone fragmentation was determined by the weight percent of stone fragments less than 2 mm. For tissue injury assessment, shock wave-treated kidneys were perfused, dehydrated, cast in paraffin wax and sectioned. Digital images were captured every 120 µm and processed to determine the functional renal volume damage. Results After 500 shocks, stone fragmentation efficiency produced by the original and modified lenses was 48 ± 12% and 52 ± 17% (p=0.60), respectively. However, after 2000 shocks, the modified lens showed significantly improved stone fragmentation of 86 ± 10%, compared to 72 ± 12% for the original lens (p=0.02). Tissue injury caused by the original and modified lenses was minimal at 0.57 ± 0.44% and 0.25 ± 0.25% (p=0.27), respectively. Conclusions With lens modification, the Siemens Modularis lithotripter demonstrates significantly improved stone fragmentation with minimal tissue injury at clinically relevant acoustic pulse energy. This new lens design could potentially be retrofitted to existing lithotripters, thereby improving the effectiveness of EM lithotripters. PMID:23485509

  9. POCT PT INR - Is it adequate for patient care? A comparison of the Roche Coaguchek XS vs. Stago Star vs. Siemens BCS in patients routinely seen in an anticoagulation clinic.

    PubMed

    Baker, Wendy S; Albright, Kathleen J; Berman, Megan; Spratt, Heidi; Mann, Peggy A; Unabia, Jaime; Petersen, John R

    2017-09-01

    In this study we examined the difference in patient INR values as measured by the POCT CoaguChek XS device and central laboratory Stago Evolution and Siemens BCS XP analyzers. This study composed of 100 warfarin therapy patients and 20 coagulation normal subjects, showed that the difference between the POCT and clinical laboratory values increased with increasing INR and was exacerbated by the use of different thromboplastin reagents by the POCT and central lab. The CoaguChek XS and on-site Stago analyzers which used human recombinant (ISI=1.01) and rabbit brain thromboplastin (ISI=1.25), respectively, showed reasonable agreement for INR<3.0 (k=0.62) but significant difference for INR≥3.0 (k=0.10). In contrast, the CoaguChek XS and Siemens BCS XP, which both employed human recombinant thromboplastin (BCS ISI=1.02), showed greater agreement for the complete range INR values (INR<3.0 k=0.84; INR≥3.0 k=0.70). ECAA Poller calibrant data showed the automated instruments were performing as expected, indicating that ISI calibrations were correct but insufficient to standardize the INR values for the different thromboplastin methods across the full range of measured INRs. Central lab verification of POCT INR>5.0 with the Stago Evolution prevented adverse treatment events for the warfarin therapy patients in the six months preceding and following this investigation. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Siemens experience in PACS

    NASA Astrophysics Data System (ADS)

    Hall, Charles L.; Perry, John H.

    1990-08-01

    Experience from ten years in Picture Archiving and Communication Systems has led to a clearer understanding of the user, system, and component requirements for PACS, and the evolving market. This paper reports on one manufacturer's considerations and experiences as a PACS supplier.

  11. 75 FR 63535 - Petition for Waiver of Compliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-15

    ... Sunday, with maximum authorized speed of 65 mph. Lastly, UTA will buy a new fleet of Siemens S70 TRAX... from certain portions of 49 CFR, particularly Sec. Sec. 219 Control of Alcohol and Drug Use; 221 Rear...

  12. Potential effect of CAD systems on the detection of actionable nodules in chest CT scans during routine reporting

    NASA Astrophysics Data System (ADS)

    Wormanns, Dag; Beyer, Florian; Butzbach, Arnauld; Zierott, Livia; Heindel, Walter

    2006-03-01

    The purpose of the presented study was to determine the impact of two different CAD systems used as concur-rent reader for detection of actionable nodules (>4 mm) on the interpretation of chest CT scans during routine reporting. Fifty consecutive MDCT scans (1 mm or 1.25 mm slice thickness, 0.8 mm reconstruction increment) were se-lected from clinical routine. All cases were read by a resident and a staff radiologist, and a written report was available in the radiology information system (RIS). The RIS report mentioned at least one actionable pulmonary nodule in 18 cases (50%) and did not report any pulmonary nodule in the remaining 32 cases. Two different recent CAD systems were independently applied to the 50 CT scans as concurrent reader with two radiologists: Siemens LungCare NEV and MEDIAN CAD-Lung. Two radiologists independently reviewed the CAD results and determined if a CAD result was a true positive or a false positive finding. Patients were classified into two groups: in group A if at least one actionable nodule was detected and in group B if no actionable nodules were found. The effect of CAD on routine reporting was simulated as set union of the findings of routine reporting and CAD thus applying CAD as concurrent reader. According to the RIS report group A (patients with at least one actionable nodule) contained 18 cases (36% of all 50 cases), and group B contained 32 cases. Application of a CAD system as concurrent reader resulted in detec-tion of additional CT scans with actionable nodules and reclassification into group A in 16 resp. 18 cases (radi-ologist 1 resp. radiologist 2) with Siemens NEV and in 19 resp. 18 cases with MEDIAN CAD-Lung. In seven cases MEDIAN CAD-Lung and in four cases Siemens NEV reclassified a case into group A while the other CAD system missed the relevant finding. Sensitivity on a nodule (>4 mm) base was .45 for Siemens NEV and .55 for MEDIAN CAD-Lung; the difference was not yet significant (p=.077). In our study use of CAD as second reader in routine reporting doubled the percentage of patients with actionable nodules larger than 4 mm.

  13. Dependence of Achievable Plan Quality on Treatment Technique and Planning Goal Refinement: A Head-and-Neck Intensity Modulated Radiation Therapy Application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, X. Sharon, E-mail: xqi@mednet.ucla.edu; Ruan, Dan; Lee, Steve P.

    2015-03-15

    Purpose: To develop a practical workflow for retrospectively analyzing target and normal tissue dose–volume endpoints for various intensity modulated radiation therapy (IMRT) delivery techniques; to develop technique-specific planning goals to improve plan consistency and quality when feasible. Methods and Materials: A total of 165 consecutive head-and-neck patients from our patient registry were selected and retrospectively analyzed. All IMRT plans were generated using the same dose–volume guidelines for TomoTherapy (Tomo, Accuray), TrueBeam (TB, Varian) using fixed-field IMRT (TB-IMRT) or RAPIDARC (TB-RAPIDARC), or Siemens Oncor (Siemens-IMRT, Siemens). A MATLAB-based dose–volume extraction and analysis tool was developed to export dosimetric endpoints for eachmore » patient. With a fair stratification of patient cohort, the variation of achieved dosimetric endpoints was analyzed among different treatment techniques. Upon identification of statistically significant variations, technique-specific planning goals were derived from dynamically accumulated institutional data. Results: Retrospective analysis showed that although all techniques yielded comparable target coverage, the doses to the critical structures differed. The maximum cord doses were 34.1 ± 2.6, 42.7 ± 2.1, 43.3 ± 2.0, and 45.1 ± 1.6 Gy for Tomo, TB-IMRT, TB-RAPIDARC, and Siemens-IMRT plans, respectively. Analyses of variance showed significant differences for the maximum cord doses but no significant differences for other selected structures among the investigated IMRT delivery techniques. Subsequently, a refined technique-specific dose–volume guideline for maximum cord dose was derived at a confidence level of 95%. The dosimetric plans that failed the refined technique-specific planning goals were reoptimized according to the refined constraints. We observed better cord sparing with minimal variations for the target coverage and other organ at risk sparing for the Tomo cases, and higher parotid doses for C-arm linear accelerator–based IMRT and RAPIDARC plans. Conclusion: Patient registry–based processes allowed easy and systematic dosimetric assessment of treatment plan quality and consistency. Our analysis revealed the dependence of certain dosimetric endpoints on the treatment techniques. Technique-specific refinement of planning goals may lead to improvement in plan consistency and plan quality.« less

  14. Concentrating Solar Power Projects - Ivanpah Solar Electric Generating

    Science.gov Websites

    Energy; Google Technology: Power tower Turbine Capacity: Net: 377.0 MW Gross: 392.0 MW Status Turbine Capacity (Gross): 392.0 MW Turbine Capacity (Net): 377.0 MW Turbine Manufacturer: Siemens SST-900

  15. 76 FR 79224 - Investigations Regarding Certifications of Eligibility To Apply for Worker Adjustment Assistance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-21

    ... Clariant Corp (Company)..... Martin, SC 11/29/11 11/29/11 81117 Sykes Enterprise Inc., Re: Grand Junction...). 81121 Third Degree Graphics & Ventura, CA 11/29/11 11/21/11 Marketing (Workers). 81122 Siemens Energy...

  16. Connectivist Communication Networks

    ERIC Educational Resources Information Center

    Waßmann, Ingolf; Nicolay, Robin; Martens, Alke

    2016-01-01

    Facing the challenges of the digital age concerning lifelong learning, this contribution presents an approach to dynamically establish Connectivist communication networks. According the statement "the pipe is more important than the content within the pipe" by Georg Siemens, learning in digital age includes the connection of people to…

  17. 75 FR 15736 - Investigations Regarding Certifications of Eligibility To Apply for Worker Adjustment Assistance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-30

    ... Kansas City, MO....... 02/22/10 02/10/10 Pharmaceuticals (Comp). 73543 Bumble Bee Foods, LLC (Comp..., Siemens World Boise, ID 02/24/10 02/23/10 Travel (Wkrs). 73561 Musashi Auto Parts (State).. Battle Creek...

  18. 76 FR 22733 - Investigations Regarding Certifications of Eligibility To Apply for Worker Adjustment Assistance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-22

    ...). 80090 Whitman Packaging Corp. Islandia, NY 04/06/11 03/31/11 (State/One-Stop). 80091 G&G Garments (State... Company (Company). 80099 Siemens Industry Inc. Bellefontaine, OH......... 04/08/11 04/08/11 (Workers). [FR...

  19. Analytical and clinical performance of thyroglobulin autoantibody assays in thyroid cancer follow-up.

    PubMed

    Katrangi, Waddah; Grebe, Stephan K G; Algeciras-Schimnich, Alicia

    2017-10-26

    While thyroglobulin autoantibodies (TgAb) can result in false low serum thyroglobulin (Tg) immunoassay (IA) measurements, they might also be indicators of disease persistence/recurrence. Hence, accurate TgAb measurement, in addition to Tg quantification, is crucial for thyroid cancer monitoring. We compared the analytical and clinical performance of four commonly used TgAb IAs. We measured Tg by mass spectrometry (Tg-MS) and by four pairs of Tg and TgAb IAs (Beckman, Roche, Siemens, Thermo) in 576 samples. Limit of quantitation (LOQ) and manufacturers' upper reference interval cut-off (URI) were used for comparisons. Clinical performance was assessed by receiving operator characteristics (ROC) curve analysis. Quantitative and qualitative agreement between TgAb-IAs was moderate with R2 of 0.20-0.70 and κ from 0.41-0.66 using LOQ and 0.47-0.71 using URI. In samples with TgAb interference, detection rates of TgAb were similar using LOQ and URI for Beckman, Siemens, and Thermo, but much lower for the Roche TgAb-IA when the URI was used. In TgAb positive cases, the ROC areas under the curve (AUC) for the TgAb-IAs were 0.59 (Beckman), 0.62 (Siemens), 0.59 (Roche), and 0.59 (Thermo), similar to ROC AUCs achieved with Tg. Combining Tg and TgAb measurements improved the ROC AUCs compared to Tg or TgAb alone. TgAb-IAs show significant qualitative and quantitative differences. For 2 of the 4 TgAb-IAs, using the LOQ improves the detection of interfering TgAbs. All assays showed suboptimal clinical performance when used as surrogate markers of disease, with modest improvements when Tg and TgAb were combined.

  20. Athena X-IFU event reconstruction software: SIRENA

    NASA Astrophysics Data System (ADS)

    Ceballos, Maria Teresa; Cobo, Beatriz; Peille, Philippe; Wilms, Joern; Brand, Thorsten; Dauser, Thomas; Bandler, Simon; Smith, Stephen

    2015-09-01

    This contribution describes the status and technical details of the SIRENA package, the software currently in development to perform the on board event energy reconstruction for the Athena calorimeter X-IFU. This on board processing will be done in the X-IFU DRE unit and it will consist in an initial triggering of event pulses followed by an analysis (with the SIRENA package) to determine the energy content of such events.The current algorithm used by SIRENA is the optimal filtering technique (also used by ASTRO-H processor) although some other algorithms are also being tested.Here we present these studies and some preliminary results about the energy resolution of the instrument based on simulations done with the SIXTE simulator (http://www.sternwarte.uni-erlangen.de/research/sixte/) in which SIRENA is integrated.

  1. Dollar Summary of Prime Contract Awards with Principal Place of Performance Outside the U.S. by Country and Contractor, FY83.

    DTIC Science & Technology

    1983-01-01

    GERMANY 55 55 KOHLEN GRUB GERMANY 9,706 9,706 KOLLER WOLFGANG GERMANY 28 28 KOLLSMANN 0MBN SYSTEM TECHN IK GERMANY 37 37 KONTRO#4 ELEKTRONI C GMBH... KRAUSE GERMANY 56 56 WAGNER GLAS UND GEBAEUDEREINIGUNG GERMANY 374 374 WAGNER GMSM GERMANY 138 136 WAGNER H GERMANY 570 570 WAGNER H a S GARTEN... WOLFGANG PRAYON GERMANY 34 34 WOLLERSHE I M ALFRED GERMANY 47 47 WORMSER AUIOBUSSETRI ED GERMANY 178 178 WUERSCHINGER HANS GERMANY 73 73 WUEST BAU

  2. Machine Aids to Translation.

    ERIC Educational Resources Information Center

    Brinkmann, Karl-Heinz

    1981-01-01

    Describes the TEAM Program System of the Siemens Language Services Department, particularly the main features of its terminology data bank. Discusses criteria to which stored terminology must conform and methods of data bank utilization. Concludes by summarizing the consequences that machine-aided translation development has had for the…

  3. Comparison of Abbott Architect®, Siemens Immulite®, and Diasorin Liaison® for determination of Epstein-Barr virus serological diagnosis.

    PubMed

    François, Catherine; Segard, Christine; Bouvier, Maryline; Stefanski, Martine; Pannier, Christine; Zawadzki, Patricia; Roussel, Catherine; Hecquet, Denise; Duverlie, Gilles; Brochot, Etienne; Castelain, Sandrine

    2018-02-01

    This study compared the performance of 3 automated immunoassays, Architect ® (Abbott), Immulite ® (Siemens) and Liaison ® (Diasorin), for Epstein-Barr virus (EBV) serology. Ninety-one serum samples collected in Amiens University Hospital were analyzed for the presence of Viral Capsid Antigen (VCA) IgG and IgM and Epstein-Barr Nuclear Antigen (EBNA) IgG. The agreement between the 3 assays was calculated for each marker individually and for determination of the EBV profile, based on interpretation of the combination of these 3 EBV markers. Although similar results were obtained with Architect ® and Liaison ® , several discordant results were observed with Immulite ® , particularly for EBNA IgG. A large number of EBNA IgG-positive results were observed, which interfered with interpretation of the EBV profile. In contrast, Immulite ® performed similarly to the 2 other assays for detection of VCA IgM. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. The control system of the polarized internal target of ANKE at COSY

    NASA Astrophysics Data System (ADS)

    Kleines, H.; Sarkadi, J.; Zwoll, K.; Engels, R.; Grigoryev, K.; Mikirtychyants, M.; Nekipelov, M.; Rathmann, F.; Seyfarth, H.; Kravtsov, P.; Vasilyev, A.

    2006-05-01

    The polarized internal target for the ANKE experiment at the Cooler Synchrotron COSY of the Forschungszentrum Jülich utilizes a polarized atomic beam source to feed a storage cell with polarized hydrogen or deuterium atoms. The nuclear polarization is measured with a Lamb-shift polarimeter. For common control of the two systems, industrial equipment was selected providing reliable, long-term support and remote control of the target as well as measurement and optimization of its operating parameters. The interlock system has been implemented on the basis of SIEMENS SIMATIC S7-300 family of programmable logic controllers. In order to unify the interfacing to the control computer, all front-end equipment is connected via the PROFIBUS DP fieldbus. The process control software was implemented using the Windows-based WinCC toolkit from SIEMENS. The variety of components, to be controlled, and the logical structure of the control and interlock system are described. Finally, a number of applications derived from the present development to other, new installations are briefly mentioned.

  5. Development of a Polysilicon Process Based on Chemical Vapor Deposition of Dichlorosilane in an Advanced Siemen's Reactor

    NASA Technical Reports Server (NTRS)

    Arevidson, A. N.; Sawyer, D. H.; Muller, D. M.

    1983-01-01

    Dichlorosilane (DCS) was used as the feedstock for an advanced decomposition reactor for silicon production. The advanced reactor had a cool bell jar wall temperature, 300 C, when compared to Siemen's reactors previously used for DCS decomposition. Previous reactors had bell jar wall temperatures of approximately 750 C. The cooler wall temperature allows higher DCS flow rates and concentrations. A silicon deposition rate of 2.28 gm/hr-cm was achieved with power consumption of 59 kWh/kg. Interpretation of data suggests that a 2.8 gm/hr-cm deposition rate is possible. Screening of lower cost materials of construction was done as a separate program segment. Stainless Steel (304 and 316), Hastalloy B, Monel 400 and 1010-Carbon Steel were placed individually in an experimental scale reactor. Silicon was deposited from trichlorosilane feedstock. The resultant silicon was analyzed for electrically active and metallic impurities as well as carbon. No material contributed significant amounts of electrically active or metallic impurities, but all contributed carbon.

  6. Micalastic high-voltage insulation: Design features and experience

    NASA Astrophysics Data System (ADS)

    Wichmann, A.

    1981-12-01

    High-quality mica, carefully selected epoxy resins and a well-matched vacuum/pressure impregnation process determine the characteristics of the MICALASTIC insulation for large turbine-generators. Logical development and process manufacturing quality control have led to an insulation system of high quality and operating reliability. The first winding of a turbine-generator being impregnated and cured under vacuum with solvent-free synthetic resin in 1958 was designed for 10.5 kV rated voltage. Ever since, Siemens AG and Kraftwerk Union AG have used this type of insulation for all direct-cooled windings and also for an increasing number of indirect-cooled windings. At present, 240 turbine-generators with a total of more than 115,000 MVA output have been built. Since 1960, this insulation system has been registered for Siemens AG under the trade name MICALASTIC. The stator windings of the largest, single-shaft generators to date, rated 1560 MVA, 27 kV, has been built with MICALASTIC insulation.

  7. Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cunningham, Jane D., E-mail: janecunningham0708@gmail.com; McCusker, Mark W.; Power, Sarah

    PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neckmore » lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.« less

  8. Clinical Implications of TiGRT Algorithm for External Audit in Radiation Oncology.

    PubMed

    Shahbazi-Gahrouei, Daryoush; Saeb, Mohsen; Monadi, Shahram; Jabbari, Iraj

    2017-01-01

    Performing audits play an important role in quality assurance program in radiation oncology. Among different algorithms, TiGRT is one of the common application software for dose calculation. This study aimed to clinical implications of TiGRT algorithm to measure dose and compared to calculated dose delivered to the patients for a variety of cases, with and without the presence of inhomogeneities and beam modifiers. Nonhomogeneous phantom as quality dose verification phantom, Farmer ionization chambers, and PC-electrometer (Sun Nuclear, USA) as a reference class electrometer was employed throughout the audit in linear accelerators 6 and 18 MV energies (Siemens ONCOR Impression Plus, Germany). Seven test cases were performed using semi CIRS phantom. In homogeneous regions and simple plans for both energies, there was a good agreement between measured and treatment planning system calculated dose. Their relative error was found to be between 0.8% and 3% which is acceptable for audit, but in nonhomogeneous organs, such as lung, a few errors were observed. In complex treatment plans, when wedge or shield in the way of energy is used, the error was in the accepted criteria. In complex beam plans, the difference between measured and calculated dose was found to be 2%-3%. All differences were obtained between 0.4% and 1%. A good consistency was observed for the same type of energy in the homogeneous and nonhomogeneous phantom for the three-dimensional conformal field with a wedge, shield, asymmetric using the TiGRT treatment planning software in studied center. The results revealed that the national status of TPS calculations and dose delivery for 3D conformal radiotherapy was globally within acceptable standards with no major causes for concern.

  9. [Value of combined conventional and contrast enhanced sonography in the evaluation of hepatic disorders].

    PubMed

    Tranquart, F; Bleuzen, A; Kissel, A

    2004-06-01

    To assess the value of combined conventional and contrast-material enhanced sonography for the characterization of focal liver lesions. Simultaneous imaging with grey scale and contrast enhanced US was performed in 90 patients following Levovist injection (Schering, Berlin, Germany) using the "Agent Detection Imaging" method (ADI, Siemens-Acuson, Mountain View, USA). US scanning was performed at least 4 minutes after contrast injection with review of both grayscale and contrast enhanced modes. Results for detection and characterization of lesions were compared to the selected gold standard imaging modality (CT or MRI). Final diagnoses included: 20 normal examinations, 41 patients with metastases, 6 patients with hepatocellular carcinoma, 13 patients with hemangioma, 6 patients with other benign lesions, 4 patients with cysts and 6 patients with two types of lesions. Delayed phase contrast enhanced US allowed diagnosis of all lesions except for one metastasis and all hepatocellular carcinomas. While the diagnosis of hepatoma could not be confirmed, the features suggested a malignant etiology. For 7 patients with metastases, more lesions were detected at ADI (4.9 lesions) than at conventional US (1.1 lesion). For 3 patients, CT showed more lesions than ADI US (3.3 versus 1.6 lesions). The accuracy of ADI US for differentiating between benign and malignant lesions was 98.7% compared to 49.6% for conventional US (p<0.001). The total number of lesions detected at ADI US was higher (p<0.01) than at conventional US and not significantly different from that obtained by the gold standard reference methods. Complete characterization was achieved in 92.2% of cases with ADI US compared to 59.2% with conventional US (p<0.001). Contrast-material enhanced US combined with conventional US markedly improves the diagnostic accuracy of US in terms of lesion detection and characterization.

  10. Medication History versus Point-of-Care Platelet Activity Testing in Patients with Intracerebral Hemorrhage.

    PubMed

    Maas, Matthew B; Naidech, Andrew M; Kim, Minjee; Batra, Ayush; Manno, Edward M; Sorond, Farzaneh A; Prabhakaran, Shyam; Liotta, Eric M

    2018-05-01

    We evaluated whether reduced platelet activity detected by point-of-care (POC) testing is a better predictor of hematoma expansion and poor functional outcomes in patients with intracerebral hemorrhage (ICH) than a history of antiplatelet medication exposure. Patients presenting with spontaneous ICH were enrolled in a prospective observational cohort study that collected demographic, clinical, laboratory, and radiographic data. We measured platelet activity using the PFA-100 (Siemens AG, Germany) and VerifyNow-ASA (Accumetrics, CA) systems on admission. We performed univariate and adjusted multivariate analyses to assess the strength of association between those measures and (1) hematoma growth at 24 hours and (2) functional outcomes measured by the modified Rankin Scale (mRS) at 3 months. We identified 278 patients for analysis (mean age 65 ± 15, median ICH score 1 [interquartile range 0-2]), among whom 164 underwent initial neuroimaging within 6 hours of symptom onset. Univariate association with hematoma growth was stronger for antiplatelet medication history than POC measures, which was confirmed in multivariable models (β 3.64 [95% confidence interval [CI] 1.02-6.26], P = .007), with a larger effect size measured in the under 6-hour subgroup (β 7.20 [95% CI 3.35-11.1], P < .001). Moreover, antiplatelet medication history, but not POC measures of platelet activity, was independently associated with poor outcome at 3 months (mRS 4-6) in the under 6-hour subgroup (adjusted OR 3.6 [95% CI 1.2-11], P = .023). A history of antiplatelet medication use better identifies patients at risk for hematoma growth and poor functional outcomes than POC measures of platelet activity after spontaneous ICH. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  11. Pediatric chest and abdominopelvic CT: organ dose estimation based on 42 patient models.

    PubMed

    Tian, Xiaoyu; Li, Xiang; Segars, W Paul; Paulson, Erik K; Frush, Donald P; Samei, Ehsan

    2014-02-01

    To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. The institutional review board approved this HIPAA-compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0-16 years; weight range, 2-80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDI(vol)). The relationships between CTDI(vol)-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. For organs within the image coverage, CTDI(vol)-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R(2) > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%-32%) mainly because of the effect of overranging. It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDI(vol). These CTDI(vol)-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. © RSNA, 2013.

  12. Brain networks associated with cognitive and hedonic responses to a meal.

    PubMed

    Pribic, T; Kilpatrick, L; Ciccantelli, B; Malagelada, C; Accarino, A; Rovira, A; Pareto, D; Mayer, E; Azpiroz, F

    2017-06-01

    We recently reported interrelated digestive, cognitive, and hedonic responses to a meal. The aim of this study was to identify brain networks related to the hedonic response to eating. Thirty-eight healthy subjects (20-38 age range) were evaluated after a 5-hour fast and after ingestion of a test meal (juice and warm ham and cheese sandwich, 300 mL, 425 kcal). Perceptual and affective responses (satiety, abdominal fullness, digestive well-being, and positive mood), and resting scans of the brain using functional MRI (3T Trio, Siemens, Germany) were evaluated immediately before and after the test meal. A high-order group independent component analysis was performed to investigate ingestion-related changes in the intrinsic connectivity of brain networks, with a focus on thalamic and insular networks. Ingestion induced satiation (3.3±0.4 score increase; P<.001) and abdominal fullness (2.4±0.3 score increase; P<.001). These sensations included an affective dimension involving digestive well-being (2.8±0.3 score increase; P<.001) and positive mood (1.8±0.2 score increase; P<.001). In general, thalamo-cortical connectivity increased with meal ingestion while insular-cortical connectivity mainly decreased. Furthermore, larger meal-induced changes (increase/decrease) in specific thalamic connections were associated with smaller changes in satiety/fullness. In contrast, a larger meal-induced decrease in insular-anterior cingulate cortex connectivity was associated with increased satiety, fullness, and digestive well-being. Perceptual and emotional responses to food intake are related to brain connectivity in defined functional networks. Brain imaging may provide objective biomarkers of subjective effects of meal ingestion. © 2017 John Wiley & Sons Ltd.

  13. Improving Echo-Guided Procedures Using an Ultrasound-CT Image Fusion System.

    PubMed

    Diana, Michele; Halvax, Peter; Mertz, Damien; Legner, Andras; Brulé, Jean-Marcel; Robinet, Eric; Mutter, Didier; Pessaux, Patrick; Marescaux, Jacques

    2015-06-01

    Image fusion between ultrasound (US) and computed tomography (CT) scan or magnetic resonance can increase operator accuracy in targeting liver lesions, particularly when those are undetectable with US alone. We have developed a modular gel to simulate hepatic solid lesions for educational purposes in imaging and minimally invasive ablation techniques. We aimed to assess the impact of image fusion in targeting artificial hepatic lesions during the hands-on part of 2 courses (basic and advanced) in hepatobiliary surgery. Under US guidance, 10 fake tumors of various sizes were created in the livers of 2 pigs, by percutaneous injection of a biocompatible gel engineered to be hyperdense on CT scanning and barely detectable on US. A CT scan was obtained and a CT-US image fusion was performed using the ACUSON S3000 US system (Siemens Healthcare, Germany). A total of 12 blinded course attendants, were asked in turn to perform a 10-minute liver scan with US alone followed by a 10-minute scan using image fusion. Using US alone, the expert managed to identify all lesions successfully. The true positive rate for course attendants with US alone was 14/36 and 2/24 in the advanced and basic courses, respectively. The total number of false positives identified was 26. With image fusion, the rate of true positives significantly increased to 31/36 (P < .001) in the advanced group and 16/24 in the basic group (P < .001). The total number of false positives, considering all participants, decreased to 4 (P < .001). Image fusion significantly increases accuracy in targeting hepatic lesions and might improve echo-guided procedures. © The Author(s) 2015.

  14. [Usefulness of curved coronal MPR imaging for the diagnosis of cervical radiculopathy].

    PubMed

    Inukai, Chikage; Inukai, Takashi; Matsuo, Naoki; Shimizu, Ikuo; Goto, Hisaharu; Takagi, Teruhide; Takayasu, Masakazu

    2010-03-01

    In surgical treatment of cervical radiculopathy, localization of the responsible lesions by various imaging modalities is essential. Among them, MRI is non-invasive and plays a primary role in the assessment of spinal radicular symptoms. However, demonstration of nerve root compression is sometimes difficult by the conventional methods of MRI, such as T1 weighted (T1W) and T2 weighted (T2W) sagittal or axial images. We have applied a new technique of curved coronal multiplanar reconstruction (MPR) imaging for the diagnosis of cervical radiculopathy. Ten patients (4 male, 6 female) with ages between 31 and 79 year-old, who had clinical diagnosis of cervical radiculopathy, were included in this study. Seven patients underwent anterior key-hole foraminotomy to decompress the nerve root with successful results. All the patients had 3D MRI studies, such as true fast imaging with steady-state precession (FISP), 3DT2W sampling perfection with application optimized contrasts using different fillip angle evolution (SPACE), and 3D multi-echo data image combination (MEDIC) imagings in addition to the routine MRI (1.5 T Avanto, Siemens, Germany) with a phased array coil. The curved coronal MPR images were produced from these MRI data using a workstation. The nerve root compression was diagnosed by curved coronal MPR images in all the patients. The compression sites were compatible with those of the operative findings in 7 patients, who underwent surgical treatment. The MEDIC imagings were the most demonstrable to visualize the nerve root, while the 3D-space imagings were the next. The curved coronal MPR imaging is useful for the diagnosis of accurate localization of the compressing lesions in patients with cervical radiculopathy.

  15. Validation of proton stopping power ratio estimation based on dual energy CT using fresh tissue samples

    NASA Astrophysics Data System (ADS)

    Taasti, Vicki T.; Michalak, Gregory J.; Hansen, David C.; Deisher, Amanda J.; Kruse, Jon J.; Krauss, Bernhard; Muren, Ludvig P.; Petersen, Jørgen B. B.; McCollough, Cynthia H.

    2018-01-01

    Dual energy CT (DECT) has been shown, in theoretical and phantom studies, to improve the stopping power ratio (SPR) determination used for proton treatment planning compared to the use of single energy CT (SECT). However, it has not been shown that this also extends to organic tissues. The purpose of this study was therefore to investigate the accuracy of SPR estimation for fresh pork and beef tissue samples used as surrogates of human tissues. The reference SPRs for fourteen tissue samples, which included fat, muscle and femur bone, were measured using proton pencil beams. The tissue samples were subsequently CT scanned using four different scanners with different dual energy acquisition modes, giving in total six DECT-based SPR estimations for each sample. The SPR was estimated using a proprietary algorithm (syngo.via DE Rho/Z Maps, Siemens Healthcare, Forchheim, Germany) for extracting the electron density and the effective atomic number. SECT images were also acquired and SECT-based SPR estimations were performed using a clinical Hounsfield look-up table. The mean and standard deviation of the SPR over large volume-of-interests were calculated. For the six different DECT acquisition methods, the root-mean-square errors (RMSEs) for the SPR estimates over all tissue samples were between 0.9% and 1.5%. For the SECT-based SPR estimation the RMSE was 2.8%. For one DECT acquisition method, a positive bias was seen in the SPR estimates, having a mean error of 1.3%. The largest errors were found in the very dense cortical bone from a beef femur. This study confirms the advantages of DECT-based SPR estimation although good results were also obtained using SECT for most tissues.

  16. Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients.

    PubMed

    Kirchner, J; Kickuth, R; Laufer, U; Noack, M; Liermann, D

    2000-05-01

    Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Copyright 2000 The Royal College of Radiologists.

  17. Indeterminate RIBA results were associated with the absence of hepatitis C virus RNA (HCV-RNA) in blood donors.

    PubMed

    Pereira, Felicidade Mota; Zarife, Maria Alice Sant'ana; Reis, Eliana Almeida Gomes; G Reis, Mitermayer

    2014-01-01

    Hepatitis C virus (HCV) infection is diagnosed by the presence of antibodies and is supplemented by confirmatory testing methods, such as recombinant immunoblot assay (RIBA) and HCV-RNA detection. This study aimed to evaluate the efficacy of RIBA testing to diagnose HCV infection in blood donors positive for anti-HCV antibodies. A total of 102 subjects positive for anti-HCV determined by enzyme-linked immunosorbent assay (ELISA) at the Hematology and Hemotherapy Foundation of Bahia (HEMOBA) were later assessed with new samples using the Abbott Architect anti-HCV test (Abbott Diagnostics, Wiesbaden, Germany), the RIBA III test (Chiron RIBA HCV 3.0 SIA, Chiron Corp., Emeryville, CA, USA), the polymerase chain reaction (PCR; COBAS® AMPLICOR HCV Roche Diagnostics Corp., Indianapolis, IN, USA) and line probe assay (LiPA - Siemens, Tarrytown, NY, USA) genotyping for HCV diagnosis. Of these new samples, 38.2% (39/102) were positive, 57.8% (59/102) were negative and 3.9% (4/102) were indeterminate for anti-HCV; HCV-RNA was detected in 22.5% (23/102) of the samples. RIBA results were positive in 58.1% (25/43), negative in 9.3% (4/43) and indeterminate in 32.6% (14/43) of the samples. The prevailing genotypes were 1 (78.3%, 18/23), 3 (17.4%, 4/23) and 2 (4.3%, 1/23). All 14 samples with indeterminate RIBA results had undetectable viral loads (detection limit ≤50 IU/mL). Of these samples, 71.4% (10/14) were reevaluated six months later. Eighty percent (8/10) of these samples remained indeterminate by RIBA, and 20% (2/10) were negative. In this study, individuals with indeterminate RIBA results had no detectable HCV-RNA.

  18. Prospective randomized investigation for evaluation of postoperative changes in the microbial climate of paranasal mucosa by the use of different dissoluting techniques during postoperative care.

    PubMed

    Maune, S; Johannssen, V; Sahly, H; Werner, J A; Salhy, H

    1999-09-01

    Endonasal dissolution by the use of NaCl-solution is a common postoperative treatment of the nasal mucosa after endonasal surgery. These procedure involve for example endonasal shower and sterilized solutions. The contamination of nasal shower in case of unprofessional cleaning after treatment was an argument against this technique in earlier discussions. The danger of such an infection should be avoided by the use of sterilized solution. Therefore the dependence of nasal microbial climate on different nasal dissoluting techniques was investigated by the use of such named endonasal shower (Siemens und Co, Bad Ems, Germany) in comparison with sterilized solution (Rhinomer, Zyma SA, Nyon, France). Microbial cultures were investigated of 80 patients after endonasal surgery (53 m, 27 f; 31 +/- 21 age). Surgery was done for the treatment of chronic polypous sinusitis. Pre-, intra- and postoperative samples were taken in 640 cases to proceed microbial cultures. Material was transferred with the use of a Port-A-Cul-transport medium and preparation of the microbial cultures was done during the first four hours. As a result 895 bacterial clones were cultivated. These consisted of 87% aerob and 13% anaerob bacteria. Staphylococcus aureus (39%) and members of the family of Enterobactericae (30%) were the most common microbes. There was neither an evidence for postoperative microbes on the nasal mucosa nor a correlation between the dissoluting technique and the postoperative outcome. The use of sterilized solutions for the postoperative care of endonasal mucosa does not cause an additional worthful effect on neither the postoperative microbial climate nor the outcome in comparison to endonasal shower.

  19. Clinical Implications of TiGRT Algorithm for External Audit in Radiation Oncology

    PubMed Central

    Shahbazi-Gahrouei, Daryoush; Saeb, Mohsen; Monadi, Shahram; Jabbari, Iraj

    2017-01-01

    Background: Performing audits play an important role in quality assurance program in radiation oncology. Among different algorithms, TiGRT is one of the common application software for dose calculation. This study aimed to clinical implications of TiGRT algorithm to measure dose and compared to calculated dose delivered to the patients for a variety of cases, with and without the presence of inhomogeneities and beam modifiers. Materials and Methods: Nonhomogeneous phantom as quality dose verification phantom, Farmer ionization chambers, and PC-electrometer (Sun Nuclear, USA) as a reference class electrometer was employed throughout the audit in linear accelerators 6 and 18 MV energies (Siemens ONCOR Impression Plus, Germany). Seven test cases were performed using semi CIRS phantom. Results: In homogeneous regions and simple plans for both energies, there was a good agreement between measured and treatment planning system calculated dose. Their relative error was found to be between 0.8% and 3% which is acceptable for audit, but in nonhomogeneous organs, such as lung, a few errors were observed. In complex treatment plans, when wedge or shield in the way of energy is used, the error was in the accepted criteria. In complex beam plans, the difference between measured and calculated dose was found to be 2%–3%. All differences were obtained between 0.4% and 1%. Conclusions: A good consistency was observed for the same type of energy in the homogeneous and nonhomogeneous phantom for the three-dimensional conformal field with a wedge, shield, asymmetric using the TiGRT treatment planning software in studied center. The results revealed that the national status of TPS calculations and dose delivery for 3D conformal radiotherapy was globally within acceptable standards with no major causes for concern. PMID:28989910

  20. Determination of 17OHPreg and DHEAS by LC-MS/MS: Impact of Age, Sex, Pubertal Stage, and BMI on the Δ5 Steroid Pathway.

    PubMed

    Kulle, Alexandra E; Reinehr, Thomas; Simic-Schleicher, Gunter; Hornig, Nadine C; Holterhus, Paul-Martin

    2017-01-01

    Dehydroepiandrosterone sulfate (DHEAS) and 17-hydroxypregnenolone (17OHPreg) are important for understanding the Δ5 pathway (e.g., in adrenarche and obesity). Although mass spectrometry has become the state-of-the-art method for quantifying steroids, there are few comprehensive age-, sex-, and pubertal stage-specific reference ranges for children. To develop a sensitive and reliable ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for simultaneous quantification of DHEAS and 17OHPreg and to establish entire age-, sex- and pubertal stage-specific reference ranges in children. A total of 684 children, 453 (243 female, 210 male) with normal body mass index (BMI; <90th) and 231 (132 female, 99 male) obese subjects (>97th), were categorized into 11 age groups, and age- and Tanner stage (PH)-specific reference ranges were determined. The limit of detection was 0.05 nmol/L for 17OHPreg and 0.5 nmol/L for DHEAS. Levels of both steroids declined after the neonatal period. Comparisons with RIA assays (Siemens, Munich, Germany) (DHEAS) and an in-house kit (17OHPreg) revealed 0.95 and 0.93, respectively, as coefficients of determination. Although DHEAS-generally higher in boys-increased continuously starting at 3 to 6 years, 17OHPreg remained largely constant. In obese patients, both were significantly elevated, also in part after alignment to Tanner stages (PH). UPLC-MS/MS is sensitive and reliable for quantifying DHEAS and 17OHPreg. Our data support differential maturation of CYP17 during adrenarche with successively increasing 17,20-lyase activity but largely constant 17α-hydroxylation activity. Endocrine interpretation of 17OHPreg and DHEAS must consider differential patterns for age, sex, pubertal stage, and BMI. Copyright © 2017 by the Endocrine Society

  1. Energy Limits in Second Generation High-pitch Dual Source CT - Comparison in an Upper Abdominal Phantom

    PubMed Central

    Beeres, Martin; Bauer, Ralf W; Kerl, Josef M; Vogl, Thomas J; Lee, Clara

    2015-01-01

    Objectives: The aim of our study was to find out how much energy is applicable in second-generation dual source high-pitch computed tomography (CT) in imaging of the abdomen. Materials and Methods: We examined an upper abdominal phantom using a Somatom Definition Flash CT-Scanner (Siemens, Forchheim, Germany). The study protocol consisted of a scan-series at 100 kV and 120 kV. In each scan series we started with a pitch of 3.2 and reduced it in steps of 0.2, until a pitch of 1.6 was reached. The current was adjusted to the maximum the scanner could achieve. Energy values, image noise, image quality, and radiation exposure were evaluated. Results: For a pitch of 3.2 the maximum applicable current was 142 mAs at 120 kV and in 100 kV the maximum applicable current was 114 mAs. For conventional abdominal imaging, current levels of 200 to 260 mAs are generally used. To achieve similar current levels, we had to decrease the pitch to 1.8 at 100 kV — at this pitch we could perform our imaging at 204 mAs. At a pitch of 2.2 in 120 kV we could apply a current of 206 mAs. Conclusion: We conclude our study by stating that if there is a need for a higher current, we have to reduce the pitch. In a high-pitch dual source CT, we always have to remember where our main focus is, so we can adjust the pitch to the energy we need in the area of the body that has to be imaged, to find answers to the clinical question being raised. PMID:25806137

  2. 77 FR 5847 - Manufacturer of Controlled Substances; Notice of Application

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-06

    ... DEPARTMENT OF JUSTICE Drug Enforcement Administration Manufacturer of Controlled Substances; Notice of Application Pursuant to Sec. 1301.33(a) Title 21 of the Code of Federal Regulations (CFR), this is notice that on December 20, 2011, Siemens Healthcare Diagnostics Inc., 100 GBC Drive, Mail Stop...

  3. 76 FR 25375 - Manufacturer of Controlled Substances; Notice of Application

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-04

    ... DEPARTMENT OF JUSTICE Drug Enforcement Administration Manufacturer of Controlled Substances; Notice of Application Pursuant to Sec. 1301.33(a) Title 21 of the Code of Federal Regulations (CFR), this is notice that on February 15, 2011, Siemens Healthcare Diagnostics Inc., Attn: RA, 100 GBC Drive...

  4. A Brief Survey of the Team Software ProcessSM (TSPSM)

    DTIC Science & Technology

    2011-10-24

    spent more than 20 years in industry as a software engineer, system designer, project leader, and development manager working on control systems...InnerWorkings, Inc. Instituto Tecnologico y de Estudios Superiores de Monterrey Siemens AG SILAC Ingenieria de Software S.A. de C.V

  5. MO-E-17A-01: BEST IN PHYSICS (IMAGING) - Calculating SSDE From CT Exams Using Size Data Available in the DICOM Header of CT Localizer Radiographs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMillan, K; Bostani, M; McNitt-Gray, M

    2014-06-15

    Purpose: To demonstrate the feasibility of using existing data stored within the DICOM header of certain CT localizer radiographs as a patient size metric for calculating CT size-specific dose estimates (SSDE). Methods: For most Siemens CT scanners, the CT localizer radiograph (topogram) contains a private DICOM field that stores an array of numbers describing AP and LAT attenuation-based measures of patient dimension. The square root of the product of the AP and LAT size data, which provides an estimate of water-equivalent-diameter (WED), was calculated retrospectively from topogram data of 20 patients who received clinically-indicated abdomen/pelvis (n=10) and chest (n=10) scansmore » (WED-topo). In addition, slice-by-slice water-equivalent-diameter (WED-image) and effective diameter (ED-image) values were calculated from the respective image data. Using TG-204 lookup tables, size-dependent conversion factors were determined based upon WED-topo, WED-image and ED-image values. These conversion factors were used with the reported CTDIvol to calculate slice-by-slice SSDE for each method. Averaging over all slices, a single SSDE value was determined for each patient and size metric. Patientspecific SSDE and CTDIvol values were then compared with patientspecific organ doses derived from detailed Monte Carlo simulations of fixed tube current scans. Results: For abdomen/pelvis scans, the average difference between liver dose and CTDIvol, SSDE(WED-topo), SSDE(WED-image), and SSDE(ED-image) was 18.70%, 8.17%, 6.84%, and 7.58%, respectively. For chest scans, the average difference between lung dose and CTDIvol, SSDE(WED-topo), SSDE(WED-image), and SSDE(ED-image) was 25.80%, 3.33%, 4.11%, and 7.66%, respectively. Conclusion: SSDE calculated using WED derived from data in the DICOM header of the topogram was comparable to SSDE calculated using WED and ED derived from axial images; each of these estimated organ dose to within 10% for both abdomen/pelvis and chest CT examinations. The topogrambased method has the advantage that WED data are already provided and therefore available without additional post-processing of the image data. Funding Support: NIH Grant R01-EB017095; Disclosures - Michael McNitt-Gray: Institutional Research Agreement, Siemens AG; Research Support, Siemens AG; Consultant, Flaherty Sensabaugh Bonasso PLLC; Consultant, Fulbright and Jaworski; Disclosures - Cynthia McCollough: Research Grant, Siemens Healthcare.« less

  6. Innovation Concepts in Healthcare

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Requardt, Hermann

    Demographic change and advances in medical science pose increased challenges to healthcare systems globally: The economic basis is aging and thus health is becoming more and more a productivity factor. At the same time, with today’s new communication possibilities the demand and expectations of effective medical treatment have been increased. This presentation will illustrate the need for the “industrialization” of healthcare in order to achieve highest results at limited budgets. Thereby, industrialization is not meaning the medical treatment based on the assembly line approach. Rather it is to recognize the cost of medical care as an investment with respective expectationsmore » on the return of the investment. Innovations in imaging and pharmaceutical products as well as in processes - that lead to similar medical results, but with lower efforts - are keys in such scenarios. Biography Prof. Dr. Hermann Requardt, 54, is a member of the Managing Board of Siemens AG and Chief Executive Officer of the Healthcare Sector. In addition he is the CTO of Siemens AG and Head of Corporate Technology, the central research department at Siemens. After completing his studies in physics and philosophy at the Darmstadt University of Technology and Johann Wolfgang Goethe University in Frankfurt and receiving a doctorate in biophysics, he worked at the Institute of Aerospace Medicine at the German Aerospace Center.In 1984 he joined the Medical Technology Group of Siemens AG, where he was responsible for projects in the Magnetic Resonance (MR) division. He was appointed head of the division in 1995. From 2001 to 2006, as a member of the Executive Management of the Medical Solutions Group, he was responsible for several areas, including technological development.In 2006 he became a Member of the Siemens’ Managing Board and head of Corporate Technology. He was additionally appointed as the Sector Healthcare CEO in 2008.Since 2006 he is an honorary professor in physics of the Johann Wolfgang Goethe University in Frankfurt.                                                                                « less

  7. Score card endoscopy: a multicenter study to evaluate learning curves in 1-week courses using the Erlangen Endo-Trainer.

    PubMed

    Neumann, M; Hahn, C; Horbach, T; Schneider, I; Meining, A; Heldwein, W; Rösch, T; Hohenberger, W

    2003-06-01

    The present study was carried out in the context of current discussions concerning ways in which simulation systems can be integrated sensibly and effectively into clinical educational structures, in order to shorten the training period for assistants and reduce potential risks for the patient. In our study, a number of centers used a standardized training approach, in 1 week courses, to investigate the learning curve improvement that can be achieved with a group of beginners in upper gastroduodenal endoscopy. The multicenter study used the Erlangen Endo-Trainer, with specially prepared biological specimens from pigs. Using this, the individual steps of diagnostic upper gastrointestinal endoscopy with biopsy can be carried out following a score-card system. After a theoretical introduction and a demonstration of the examination by an experienced endoscopist, an initial evaluation score for each participant was obtained on day 1. On the following days, the program consisted of 2 hours' training by a tutor, followed by a test run for each participant. On days 1, 2, 3, 4, and 5 the test run was directly followed by a self-assessment. In addition, on days 1, 3, and 5 the test run for each beginner was recorded on video, with each video assigned an encrypted code number. All the end of the study week, control assessments of these videos were carried out by an experienced endoscopist. Both the self-assessments and the control assessments showed significant improvements in the endoscopic parameters tested during the course (days 1-5; all parameters P < 0.001, Wilcoxon-test). However, it was found that the trainees tended to give themselves better marks than the marks given by experienced endoscopists. During 1 week of training, using the model and following the score card, a significant improvement in the learning curve was achieved in the beginners' group for the individual steps involved in diagnostic upper gastrointestinal endoscopy. When this approach is used with trainees who are also provided with the necessary theoretical background, this type of preparation may lead to a better, lower-risk start to supervised practical endoscopic examinations in patients.

  8. [Web-based electronic patient record as an instrument for quality assurance within an integrated care concept].

    PubMed

    Händel, A; Jünemann, A G M; Prokosch, H-U; Beyer, A; Ganslandt, T; Grolik, R; Klein, A; Mrosek, A; Michelson, G; Kruse, F E

    2009-03-01

    A prerequisite for integrated care programmes is the implementation of a communication network meeting quality assurance standards. Against this background the main objective of the integrated care project between the University Eye Hospital Erlangen and the health insurance company AOK Bayern was to evaluate the potential and the acceptance of a web-based electronic patient record in the context of cataract and retinal surgery. Standardised modules for capturing pre-, intra- and post-operative data on the basis of clinical pathway guidelines for cataract- and retinal surgery have been developed. There are 6 data sets recorded per patient (1 pre-operative, 1 operative, 4-6 post-operative). For data collection, a web-based communication system (Soarian Integrated Care) has been chosen which meets the high requirements in data security, as well as being easy to handle. This teleconsultation system and the embedded electronic patient record are independent of the software used by respective offices and hospitals. Data transmission and storage were carried out in real-time. At present, 101 private ophthalmologists are taking part in the IGV contract with the University Eye Hospital Erlangen. This corresponds to 52% of all private ophthalmologists in the region. During the period from January 1st 2006 to December 31st 2006, 1844 patients were entered. Complete documentation was achieved in 1390 (75%) of all surgical procedures. For evaluation of this data, a multidimensional report and analysis tool (Cognos) was used. The deviation from target refraction as one quality indicator was in the mean 0.09 diopter. The web-based patient record used in this project was highly accepted by the private ophthalmologists. However there are still general concerns against the exchange of medical data via the internet. Nevertheless, the web-based patient record is an essential tool for a functional integration between the ambulatory and stationary health-care units. In addition to the telemedicine functions of the system, we achieved the export of the data to a data warehouse system in order to provide a flexible and powerful tool for quality assurance analysis and reporting.

  9. Exercise frequency and bone mineral density development in exercising postmenopausal osteopenic women. Is there a critical dose of exercise for affecting bone? Results of the Erlangen Fitness and Osteoporosis Prevention Study.

    PubMed

    Kemmler, Wolfgang; von Stengel, Simon; Kohl, Matthias

    2016-08-01

    Due to older people's low sports participation rates, exercise frequency may be the most critical component for designing exercise protocols that address bone. The aims of the present article were to determine the independent effect of exercise frequency (ExFreq) and its corresponding changes on bone mineral density (BMD) and to identify the minimum effective dose that just relevantly affects bone. Based on the 16-year follow-up of the intense, consistently supervised Erlangen Fitness and Osteoporosis Prevention-Study, ExFreq was retrospectively determined in the exercise-group of 55 initially early-postmenopausal females with osteopenia. Linear mixed-effect regression analysis was conducted to determine the independent effect of ExFreq on BMD changes at lumbar spine and total hip. Minimum effective dose of ExFreq based on BMD changes less than the 90% quantile of the sedentary control-group (n=43). Cut-offs were determined after 4, 8, 12 and 16years using bootstrap with 5000 replications. After 16years, average ExFreq ranged between 1.02 and 2.96sessions/week (2.28±0.40sessions/week). ExFreq has an independent effect on LS-BMD (p<.001) and hip-BMD (p=.005) changes. Bootstrap analysis detected a minimum effective dose at about 2sessions/week/16years (cut-off LS-BMD: 2.11, 95% CI: 2.06-2.12; total hip-BMD: 2.22, 95% CI: 2.00-2.78sessions/week/16years). In summary, the minimum effective dose of exercise frequency that relevantly addresses BMD is quite high, at least compared with the low sport participation rate of older adults. This result might not be generalizable across all exercise types, protocols and cohorts, but it does indicate at least that even when applying high impact/high intensity programs, exercise frequency and its maintenance play a key role in bone adaptation. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Reaching Teachers and Students: Stargazing on the Lake

    ERIC Educational Resources Information Center

    Dowling, Julie; Thomas, Jay

    2006-01-01

    With support from the Alfred P. Sloan Foundation, Siemens Foundation, and the Associated Colleges of Illinois (ACI), National Consortium for Specialized Secondary Schools of Mathematics, Science and Technology (NCSSSMST) hosted its third summer science program in June 2006 at Aurora (IL) University's Lake Geneva, Wisconsin, campus. This program…

  11. 75 FR 20001 - Manufacturer of Controlled Substances; Notice of Application

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-16

    ... DEPARTMENT OF JUSTICE Drug Enforcement Administration Manufacturer of Controlled Substances; Notice of Application Pursuant to Sec. 1301.33(a) of Title 21 of the Code of Federal Regulations (CFR), this is notice that on February 23, 2010, Siemens Healthcare Diagnostics Inc., Attn: RA, 100 GBC Drive...

  12. Participatory Pedagogy: A Compass for Transformative Learning?

    ERIC Educational Resources Information Center

    Simmons, Nicola; Barnard, Michelle; Fennema, Wendy

    2011-01-01

    In the Fall 2009 term, we participated as students and instructor in a graduate education course modeled after participatory pedagogy. Siemens (2008) defines this approach as "one that does not fully define all curricular needs in advance of interacting with learners...Multiple perspectives, opinions, and active creation on the part of…

  13. The Cyberculture Theories and Teacher Preparation at the LIFE-UFC Project in Brazil

    ERIC Educational Resources Information Center

    Junqueira, Eduardo

    2015-01-01

    This paper analyses the experience of pre-service teachers enrolled in a course at a Brazilian university that was guided by three Cyberculture Laws formulated by Lemos (2004)--which entail "transmitting connecting and reconfigurating" information and practices--and by Connectivism's concept of "relevance" (Siemens, 2004). They…

  14. OEM unveil new ideas for shovels and excavators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fiscor, S.

    2006-08-15

    From upgrades to new loading arrangements, vendors are looking at new ways to optimize the production process. The paper describes P & M equipment's new C series electric shovels equipped with the centurion system, Hitachi's super-sized excavator to Canadian oil sands, and Bucyrus and Siemens' engineer shovels. 3 figs., 1 photo.

  15. Toward New Horizons. Volume 3. Technical Intelligence Supplement

    DTIC Science & Technology

    1946-05-01

    Westtiroler Kraftwerke , a power company with plans for a 1,000,000-kw project for supplying the region of the German Rhine with power. The water requirements of... Kraftwerke and the Siemens Bau-Union, SBU, as well as Innerebner & Mayer. (b) Buildings and foundations, Arbeitsgemeinschaft Innerebner & Mayer, Ph

  16. [Contribution of the detection of IgA antibodies to the laboratory diagnosis of mumps in the population with a high vaccination coverage].

    PubMed

    Limberková, R; Smíšková, D; Havlíčková, M; Herrmannová, K; Lexová, P; Malý, M

    2015-03-01

    Serological diagnosis of epidemic mumps can be difficult in vaccinated persons, particularly due to the absence of specific IgM antibodies. The aim was to find whether adding the detection of IgA antibodies to the currently used routine serological diagnosis of mumps (detection of IgM and IgG antibodies in an acute serum sample) would make the serological diagnosis of mumps more effective in a population with a high vaccination coverage. At the same time, ELISA kits for the detection of early IgA and IgM antibodies against the mumps virus were compared and statistical analysis of the results was performed. Sixty-four acute sera from patients with laboratory confirmed diagnosis of mumps were included in the study. Clinical specimens were collected at the onset of clinical symptoms. To test the sera, the MASTAZYME ELISA Mumps IgA kit (MAST DIAGNOSTICA, Germany) with the MASTSORB sorbent (RF and IgG) and Enzygnost Anti-Parotitis-Virus/IgM kit (Siemens, Germany) were used. A panel of 121 acute sera with no epidemiological link to mumps virus served as specificity controls for the IgA assay. The epidemiological data were derived from the EPIDAT system. The level of agreement was assessed using the McNemara test and Cohen's coefficient kappa. The Stata 9.2 software (Stata Corp LP, College Station, USA) was used for statistical analysis. The detection of IgA and IgM antibodies against the mumps virus yielded concordant results in 50/64 acute sera, 32 positive and 18 negative, i.e. an agreement of 78.12 %. Of the remaining 14 samples, 13 were only IgA positive and one was only IgM positive. The controls showed non-specific IgA positivity in 5/121 samples which indicates a 96% specificity. The absence of specific IgM antibodies against mumps virus is relatively often seen in vaccinated indivi-duals; nevertheless, the test is routinely used in patients with suspected active infection. The test for IgA antibodies, which is not routinely performed, significantly increased the detection rate of the disease. Based on the results of the present study, it can be concluded that the combination of the anti-mumps IgM and IgA assays increased the effectiveness of the serological diagnosis at the onset of clinical symptoms from less than 52% to nearly 72%.

  17. Implementation of Task-Tracking Software for Clinical IT Management.

    PubMed

    Purohit, Anne-Maria; Brutscheck, Clemens; Prokosch, Hans-Ulrich; Ganslandt, Thomas; Schneider, Martin

    2017-01-01

    Often in clinical IT departments, many different methods and IT systems are used for task-tracking and project organization. Based on managers' personal preferences and knowledge about project management methods, tools differ from team to team and even from employee to employee. This causes communication problems, especially when tasks need to be done in cooperation with different teams. Monitoring tasks and resources becomes impossible: there are no defined deliverables, which prevents reliable deadlines. Because of these problems, we implemented task-tracking software which is now in use across all seven teams at the University Hospital Erlangen. Over a period of seven months, a working group defined types of tasks (project, routine task, etc.), workflows, and views to monitor the tasks of the 7 divisions, 20 teams and 340 different IT services. The software has been in use since December 2016.

  18. [Establishment and Evaluation of a Microsurgery Course for Medical Students].

    PubMed

    Beier, J P; Horch, R E; Boos, A M; Taeger, C D; Breuer, G; Arkudas, A

    2015-12-01

    Very few microsurgical courses have been offered for medical students in Germany to date. To raise early interest in this technique, which is essential for plastic and reconstructive surgery, and to guide eligible medical students to choose plastic surgery as their specialist field, the Department of Plastic and Hand Surgery, supported by the Faculty of Medicine of the Friedrich-Alexander-University of Erlangen-Nuremberg, implemented a microsurgical course for students in 2011. This study describes the implementation of that course and evaluates its impact on the subsequent choice of the participants' specialist fields. Since the summer of 2011, the microsurgery course for medical students has taken place regularly 3 times per term. It is free of charge for participants and is guided by senior physicians of the Department of Plastic and Hand Surgery together with student tutors from the Faculty of Medicine. The arterial end-to-end anastomosis in the fresh chicken leg is used as a training model. Based on a questionnaire survey the participants were evaluated and statistically analysed regarding their course satisfaction, self-assessment of their own eligibility before and after the course, the anticipated future choice of their medical specialist field and how their choice was influenced by this course. After the successful implementation of the microsurgical course in 2011, a significant number of students were interested in microsurgery. According to the questionnaire, the level of enthusiasm was high among all participants. The self-assessment of microsurgical skills improved significantly after the course compared with the pre-course assessment. In 82% of the participants, the course had a strong positive influence on the future choice of their specialist field. The regular implementation of a microsurgical course for students in the form described here is practicable and possible without undue personnel and cost of materials. The ongoing interest among students in such an offer is enormous and the satisfaction of the participants is very high. This might be a way to recruit future plastic surgeons by raising early enthusiasm for microsurgery. These future plastic surgeons, in turn, would be given the chance to experience a very fascinating aspect of plastic surgery, which might help them to decide on their specialisation within that field at a later point in their career. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Making IT ends meet. Susquehanna Health System outsources Siemens' prized product to nearby hospitals looking for an affordable alternative.

    PubMed

    Becker, Cinda

    2004-08-16

    Susquehanna Health System has been offering small, rural hospitals a more affordable information technology system through a unique outsourcing agreement. The system's CIO, Pamela Wirth, left, has advocated the provider-to-provider arrangement, which could draw the ire of some vendors.

  20. 76 FR 32228 - Notice of Determinations Regarding Eligibility To Apply for Worker Adjustment Assistance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-03

    ... identified by name by the International Trade Commission as a member of a domestic industry in an... (Formerly Enterprise Unix Division). 75,052 Siemen's Industry, Inc.. Columbus, OH....... 75,066 General... Music Holdings Pitman, NJ......... Inc., D/B/A Sony DADC Americas (``SMHI''), Sony Corporation of...

  1. 700MHz Spectrum Requirements for Canadian Public Safety Interoperable Mobile Broadband Data Communications

    DTIC Science & Technology

    2011-02-28

    activités quotidiennes que lors des interventions en situation de crise . Il existe de nouvelles technologies et applications qui peuvent accroître la...Motorola  NEC  Nortel  Nokia-Siemens  Samsung  Qualcomm  Texas Instruments 2. The introduction of new technology into a network will

  2. America's Answer

    ERIC Educational Resources Information Center

    National Math and Science Initiative, 2011

    2011-01-01

    The U.S. arm of technology giant Siemens Corp. recently reported it has 3,000 jobs open because of the dearth of skilled workers. More than half of those open jobs require science, technology, engineering and math (STEM) skills. A recent study by ManpowerGroup found that a record 52 percent of U.S. employers have difficulty filling critical…

  3. Facilitating Small-Scale Implementation of Inquiry-Based Teaching: Encounters and Experiences of Experimento Multipliers in One South African Province

    ERIC Educational Resources Information Center

    Dudu, Washington Takawira

    2017-01-01

    This paper explores the experiences of 37 physical science high school teachers who participated in a professional development (PD) programme coordinated by three Experimento multipliers. The Experimento programme is a Siemens Stiftung international educational programme aimed at providing didactic and methodological approaches to classroom…

  4. AGOR 28: SIO Shipyard Representative Bi-Weekly Progress Report

    DTIC Science & Technology

    2016-06-18

    failed due to shorted temperature sensor at the Tunnel Thruster motor. A small rectifier was found to have failed in the terminal block found in the...Active Front End (AFE). The 1n4007 Rectifier is readily available for 16-cents. Will order additional diodes for spares. Siemens to make repairs

  5. Industry Day Workshops | Energy Systems Integration Facility | NREL

    Science.gov Websites

    , 2017: Siemens-OMNETRIC Industry Day OMNETRIC Group demonstrated a distributed control hierarchy, based Systems Integration, NREL OMNETRIC Group: Grid Edge Communications and Control Utilizing an OpenFMB NREL Murali Baggu, Manager, Power Systems Operations and Control Group, NREL Santosh Veda, Research

  6. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) OF TWO CONTINUOUS EMISSION MONITORS (CEMS) FOR MEASURING AMMONIA EMISSIONS: SIEMENS AG LDS 3000, AND OPSIS AB LD500

    EPA Science Inventory

    The Environmental Technology Verification (ETV) Program, beginning as an initiative of the U.S. Environmental Protection Agency (EPA) in 1995, verifies the performance of commercially available, innovative technologies that can be used to measure environmental quality. The ETV ...

  7. Electrical, optical and structural properties of transparent conducting Al doped ZnO (AZO) deposited by sol-gel spin coating

    NASA Astrophysics Data System (ADS)

    Tonny, Kaniz Naila; Rafique, Rosaleena; Sharmin, Afrina; Bashar, Muhammad Shahriar; Mahmood, Zahid Hasan

    2018-06-01

    Al doped ZnO (AZO) films are fabricated by using sol-gel spin coating method and changes in electrical, optical and structural properties due to variation in film thickness is studied. AZO films provide c-axis orientation along the (002) plane and peak sharpness increased with film thickness is evident from XRD analysis. Conductivity (σ) of AZO films has increased from 2.34 (Siemens/cm) to 20156.27 (Siemens/cm) whereas sheet resistance (Rsh) decreases from 606300 (ohms/sq.) to 2.08 (ohm/sq.) with increase of film thickness from 296 nm to 1030 nm. Optical transmittance (T%) of AZO films is decreased from around 82% to 62% in the visible region. And grain size (D) of AZO thin films has been found to increase from 19.59 nm to 25.25 nm with increase of film thickness. Figure of Merit is also calculated for prepared sample of AZO. Among these four sample of AZO thin films, L-15 sample (having thickness in 895 nm) has provided highest figure of merit which is 5.49*10^-4 (Ω-1).

  8. A Validation and Code-to-Code Verification of FAST for a Megawatt-Scale Wind Turbine with Aeroelastically Tailored Blades

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guntur, Srinivas; Jonkman, Jason; Sievers, Ryan

    This paper presents validation and code-to-code verification of the latest version of the U.S. Department of Energy, National Renewable Energy Laboratory wind turbine aeroelastic engineering simulation tool, FAST v8. A set of 1,141 test cases, for which experimental data from a Siemens 2.3 MW machine have been made available and were in accordance with the International Electrotechnical Commission 61400-13 guidelines, were identified. These conditions were simulated using FAST as well as the Siemens in-house aeroelastic code, BHawC. This paper presents a detailed analysis comparing results from FAST with those from BHawC as well as experimental measurements, using statistics including themore » means and the standard deviations along with the power spectral densities of select turbine parameters and loads. Results indicate a good agreement among the predictions using FAST, BHawC, and experimental measurements. Here, these agreements are discussed in detail in this paper, along with some comments regarding the differences seen in these comparisons relative to the inherent uncertainties in such a model-based analysis.« less

  9. A Validation and Code-to-Code Verification of FAST for a Megawatt-Scale Wind Turbine with Aeroelastically Tailored Blades

    DOE PAGES

    Guntur, Srinivas; Jonkman, Jason; Sievers, Ryan; ...

    2017-08-29

    This paper presents validation and code-to-code verification of the latest version of the U.S. Department of Energy, National Renewable Energy Laboratory wind turbine aeroelastic engineering simulation tool, FAST v8. A set of 1,141 test cases, for which experimental data from a Siemens 2.3 MW machine have been made available and were in accordance with the International Electrotechnical Commission 61400-13 guidelines, were identified. These conditions were simulated using FAST as well as the Siemens in-house aeroelastic code, BHawC. This paper presents a detailed analysis comparing results from FAST with those from BHawC as well as experimental measurements, using statistics including themore » means and the standard deviations along with the power spectral densities of select turbine parameters and loads. Results indicate a good agreement among the predictions using FAST, BHawC, and experimental measurements. Here, these agreements are discussed in detail in this paper, along with some comments regarding the differences seen in these comparisons relative to the inherent uncertainties in such a model-based analysis.« less

  10. Do Serum Creatinine Levels Show Clinically Significant Fluctuations on Serial Determinations on the Siemens Advia 1800 Analyzer?

    PubMed

    Levitan, Daniel; Harper, Aaron E; Sun, Yi; Scarpa Carniello, Jose V; Momeni, Amir; Kagan, Joshua; Alexis, Herol; Eid, Ikram; Harris, Loretta; Marshal, Barbara; Tafani, Edlira; Pincus, Matthew

    2017-01-01

    The goal of this work was to determine whether there are clinically significant fluctuations in the level of serum creatinine on serial determinations, especially in the borderline range (1.1-1.3 mg/dl), after specimen storage. Sixty-one serum samples were analyzed. They were divided into three categories based on the initial serum creatinine measurement: low (≤1.0 mg/dl), borderline (1.1-1.3 mg/dl), and high (≥1.4 mg/dl). The specimens were stored at 4°C and run on the Siemens Advia 1800 chemistry analyzer on days 1, 3, and 11. Statistical comparisons of the three groups were made using the unpaired t-test, yielding a two-tailed P-value for each group comparison. The P-values ranged from 0.0829 to 0.3892, indicating no statistically significant difference between the standard deviations of each group. Mild-to-moderate fluctuations in precision occur in successive serum creatinine determinations. The overwhelming majority of these fluctuations should not affect clinical decision making. © 2016 Wiley Periodicals, Inc.

  11. SU-E-T-153: Burst-Mode Modulated Arc Therapy with Flattening-Filter-Free Beams Versus Flattening-Filtered Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kainz, K; Lawton, C; Li, X

    2015-06-15

    Purpose: To compare the dosimetry and delivery of burst-mode modulated arc radiotherapy using flattening-filter-free (FFF) and flattening-filtered (FF) beams. Methods: Burst-mode modulated arc therapy (mARC, Siemens) plans were generated for six prostate cases with FFF and FF beam models, using the Elekta Monaco v. 5.00 planning system. One 360-degree arc was used for five cases, and for one case two 360-degree coplanar arcs were used. The maximum number of optimization points (OPs) per arc was set to 91, and OPs with less than 4 MU were disregarded. All plans were delivered on the Siemens Artiste linear accelerator with 6MV FFmore » (300 MU/min) and comparable-energy FFF (2000 MU/min, labeled as 7UF) beams. Results: For all cases studied, the plans with FFF beams exhibited DVHs for the PTV, rectum, and bladder that were nearly identical to those for the plans with FF beams. The FFF plan yielded reduced dose to the right femoral head for 5 cases, and lower mean dose to the left femoral head for 4 cases. For all but the two-arc case, the FFF and FF plans resulted in an identical number of segments. The total number of MUs was slightly lower for the FF plans for five cases. The total delivery time per fraction was substantially lower for the FFF plans, ranging from 25 to 50 percent among all cases, as compared to the FF plans. Conclusion: For mARC plans, FFF and FF beams provided comparable PTV coverage and rectum and bladder sparing. For the femoral heads, the mean dose was slightly lower in most cases when using the FFF beam. Although the flat beam plans typically required slightly fewer MUs, FFF beams required substantially less time to deliver a plan of similar quality. This work was supported by Siemens Medical Solutions and the MCW Cancer Center Fotsch Foundation.« less

  12. Monte Carlo simulations of adult and pediatric computed tomography exams: Validation studies of organ doses with physical phantoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Daniel J.; Lee, Choonsik; Tien, Christopher

    2013-01-15

    Purpose: To validate the accuracy of a Monte Carlo source model of the Siemens SOMATOM Sensation 16 CT scanner using organ doses measured in physical anthropomorphic phantoms. Methods: The x-ray output of the Siemens SOMATOM Sensation 16 multidetector CT scanner was simulated within the Monte Carlo radiation transport code, MCNPX version 2.6. The resulting source model was able to perform various simulated axial and helical computed tomographic (CT) scans of varying scan parameters, including beam energy, filtration, pitch, and beam collimation. Two custom-built anthropomorphic phantoms were used to take dose measurements on the CT scanner: an adult male and amore » 9-month-old. The adult male is a physical replica of University of Florida reference adult male hybrid computational phantom, while the 9-month-old is a replica of University of Florida Series B 9-month-old voxel computational phantom. Each phantom underwent a series of axial and helical CT scans, during which organ doses were measured using fiber-optic coupled plastic scintillator dosimeters developed at University of Florida. The physical setup was reproduced and simulated in MCNPX using the CT source model and the computational phantoms upon which the anthropomorphic phantoms were constructed. Average organ doses were then calculated based upon these MCNPX results. Results: For all CT scans, good agreement was seen between measured and simulated organ doses. For the adult male, the percent differences were within 16% for axial scans, and within 18% for helical scans. For the 9-month-old, the percent differences were all within 15% for both the axial and helical scans. These results are comparable to previously published validation studies using GE scanners and commercially available anthropomorphic phantoms. Conclusions: Overall results of this study show that the Monte Carlo source model can be used to accurately and reliably calculate organ doses for patients undergoing a variety of axial or helical CT examinations on the Siemens SOMATOM Sensation 16 scanner.« less

  13. Design and evaluation of a THz time domain imaging system using standard optical design software.

    PubMed

    Brückner, Claudia; Pradarutti, Boris; Müller, Ralf; Riehemann, Stefan; Notni, Gunther; Tünnermann, Andreas

    2008-09-20

    A terahertz (THz) time domain imaging system is analyzed and optimized with standard optical design software (ZEMAX). Special requirements to the illumination optics and imaging optics are presented. In the optimized system, off-axis parabolic mirrors and lenses are combined. The system has a numerical aperture of 0.4 and is diffraction limited for field points up to 4 mm and wavelengths down to 750 microm. ZEONEX is used as the lens material. Higher aspherical coefficients are used for correction of spherical aberration and reduction of lens thickness. The lenses were manufactured by ultraprecision machining. For optimization of the system, ray tracing and wave-optical methods were combined. We show how the ZEMAX Gaussian beam analysis tool can be used to evaluate illumination optics. The resolution of the THz system was tested with a wire and a slit target, line gratings of different period, and a Siemens star. The behavior of the temporal line spread function can be modeled with the polychromatic coherent line spread function feature in ZEMAX. The spectral and temporal resolutions of the line gratings are compared with the respective modulation transfer function of ZEMAX. For maximum resolution, the system has to be diffraction limited down to the smallest wavelength of the spectrum of the THz pulse. Then, the resolution on time domain analysis of the pulse maximum can be estimated with the spectral resolution of the center of gravity wavelength. The system resolution near the optical axis on time domain analysis of the pulse maximum is 1 line pair/mm with an intensity contrast of 0.22. The Siemens star is used for estimation of the resolution of the whole system. An eight channel electro-optic sampling system was used for detection. The resolution on time domain analysis of the pulse maximum of all eight channels could be determined with the Siemens star to be 0.7 line pairs/mm.

  14. TU-H-207A-08: Estimating Radiation Dose From Low-Dose Lung Cancer Screening CT Exams Using Tube Current Modulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hardy, A; Bostani, M; McMillan, K

    Purpose: The purpose of this work is to estimate effective and lung doses from a low-dose lung cancer screening CT protocol using Tube Current Modulation (TCM) across patient models of different sizes. Methods: Monte Carlo simulation methods were used to estimate effective and lung doses from a low-dose lung cancer screening protocol for a 64-slice CT (Sensation 64, Siemens Healthcare) that used TCM. Scanning parameters were from the AAPM protocols. Ten GSF voxelized patient models were used and had all radiosensitive organs identified to facilitate estimating both organ and effective doses. Predicted TCM schemes for each patient model were generatedmore » using a validated method wherein tissue attenuation characteristics and scanner limitations were used to determine the TCM output as a function of table position and source angle. The water equivalent diameter (WED) was determined by estimating the attenuation at the center of the scan volume for each patient model. Monte Carlo simulations were performed using the unique TCM scheme for each patient model. Lung doses were tallied and effective doses were estimated using ICRP 103 tissue weighting factors. Effective and lung dose values were normalized by scanspecific 32 cm CTDIvol values based upon the average tube current across the entire simulated scan. Absolute and normalized doses were reported as a function of WED for each patient. Results: For all ten patients modeled, the effective dose using TCM protocols was below 1.5 mSv. Smaller sized patient models experienced lower absolute doses compared to larger sized patients. Normalized effective and lung doses showed some dependence on patient size (R2 = 0.77 and 0.78, respectively). Conclusion: Effective doses for a low-dose lung screening protocol using TCM were below 1.5 mSv for all patient models used in this study. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.« less

  15. SU-D-201-01: Attenuation of PET/CT Gantries with 511 KeV Photons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Busse, N

    2015-06-15

    Purpose: PET shielding requires the use of large amounts of lead because of the penetrating nature of 511 keV photons. While the uptake rooms generally require the thickest lead, the scan room often requires substantial shielding. Attenuation by the PET/CT gantry is normally assumed to be zero, but may be significant in directions perpendicular to the scanner axis. Methods: A 5 mL tube was filled with between 14.7 and 20.5 mCi of F-18 and inserted into a phantom (70 cm NEMA PET Scatter Phantom). Exposure rates were recorded at several distances and 15° intervals with a pressurized ionization chamber (Ludlummore » 9DP) both with the phantom outside the gantry and centered in the CT and PET acquisition positions. These measurements were repeated with three scanners: Siemens Biograph TruePoint 6, GE Optima 560, and Philips Gemini 64. Measurements were decay corrected and normalized to exposure rates outside the gantry to calculate percent transmission. Results: Between 45° to 135° (measured from the patient bed at 0°), average transmission was about 20% for GE, 35% for Philips, and 30% for Siemens. The CT gantry was roughly twice as attenuating as the PET gantry at 90° for all three manufacturers, with about 10% transmission through the CT gantry and 20% through the PET gantry. Conclusion: The Philips system is a split-gantry and therefore has a narrower angle of substantial attenuation. For the GE and Siemens systems, which are single-gantry design, transmission was relatively constant once the angle was sufficient to block line-of-sight from the phantom. While the patient may spend a greater fraction of time at the PET position of the scanner, transmission characteristics of the two components are similar enough to be treated collectively. For shielding angles between 45° and 135°, a reasonably conservative assumption would be to assume gantry transmission of 50%.« less

  16. Accuracy evaluation of distance inverse square law in determining virtual electron source location in Siemens Primus linac.

    PubMed

    Douk, Hamid Shafaei; Aghamiri, Mahmoud Reza; Ghorbani, Mahdi; Farhood, Bagher; Bakhshandeh, Mohsen; Hemmati, Hamid Reza

    2018-01-01

    The aim of this study is to evaluate the accuracy of the inverse square law (ISL) method for determining location of virtual electron source ( S Vir ) in Siemens Primus linac. So far, different experimental methods have presented for determining virtual and effective electron source location such as Full Width at Half Maximum (FWHM), Multiple Coulomb Scattering (MCS), and Multi Pinhole Camera (MPC) and Inverse Square Law (ISL) methods. Among these methods, Inverse Square Law is the most common used method. Firstly, Siemens Primus linac was simulated using MCNPX Monte Carlo code. Then, by using dose profiles obtained from the Monte Carlo simulations, the location of S Vir was calculated for 5, 7, 8, 10, 12 and 14 MeV electron energies and 10 cm × 10 cm, 15 cm × 15 cm, 20 cm × 20 cm and 25 cm × 25 cm field sizes. Additionally, the location of S Vir was obtained by the ISL method for the mentioned electron energies and field sizes. Finally, the values obtained by the ISL method were compared to the values resulted from Monte Carlo simulation. The findings indicate that the calculated S Vir values depend on beam energy and field size. For a specific energy, with increase of field size, the distance of S Vir increases for most cases. Furthermore, for a special applicator, with increase of electron energy, the distance of S Vir increases for most cases. The variation of S Vir values versus change of field size in a certain energy is more than the variation of S Vir values versus change of electron energy in a certain field size. According to the results, it is concluded that the ISL method can be considered as a good method for calculation of S Vir location in higher electron energies (14 MeV).

  17. Imaging Characteristics and Prevalence of Pancreatic Carcinoma in Kosovo During 2011-2015 - Diagnostic Method as Choice.

    PubMed

    Dedushi, Kreshnike; Kabashi, Serbeze; Mucaj, Sefedin; Hasbahta, Gazmed; Ramadani, Naser; Hoxhaj, Astrit

    2016-06-01

    Pancreatic cancer is the 10(th)most common malignancy and the 4(th)largest cancer killer in adults. The purpose of this paper is to evaluate the number of cases presented with pancreatic carcinoma during the years 2011-2015, our experience of the imaging characteristics of pancreatic carcinoma. We evaluated prevalence of the pancreatic cancers, distant metastases and other local infiltration signs among the total cases of the pancreatic cancers diagnosed in the University Clinical Center of Kosovo, with the aim to compare these research findings to similar studies made in the developed countries. This is a retrospective research study done during the period of 2011-2015. This retrospective research study includes 362 patients recently diagnosed with pancreatic cancer, examined in the period of 2011-2015 at the University Clinical Center of Kosovo. The imaging diagnostics are performed with MSCT Sensation 64 Siemens, MSCT Emotion 6 Siemens, and 1.5T MRI Symphony Siemens, biopsy guide with MSCT Sensation 64 Siemens in the Radiologic Clinic of UCCK; while the histopathology diagnostics has been performed in Clinic of Pathology at UCCK and prevalence is taken from the number of cases Reported at the Institute of Oncology Institute of Statistics and NIPH (National Institute of Public Health of Kosovo). Out of a total of the 362 patients diagnosed with pancreas cancer, results is female 39.5% (n=143) and male 61.5% (n=219), report M: F (1: 1.6), 286 cases resulted in head and neck 79 % (n=286), 76 cases resulted in body and tail cancers (21%), distant metastases in first imaging modality were found in(n=155) patients 43 %, local infiltration was found in patients: gastric infiltration 15 % (n=54), duodenal and papilla infiltration 26% (n=94), local infiltration spleen 16% (n=57), local infiltration mesentery 43 % (n= 155), dilated biliary tree 34 % (n=123), regional lymph node infiltration 83 % (n= 300). Out of a total of the 362 patients diagnosed with pancreas cancer, 346 cases resulted > 2 cm and 16 cases resulted < 2 cm and with component cystic was 41.2 % (n = 149), solid with component cystic - necrotic 33% (n= 119), solid 25.7% (n= 93). The prevalence is 19.9: 100,000 inhabitants. Prevalence of carcinoma of the pancreas for 5 years in Kosovo has proved to be prevalence is 19.9: 100,000 inhabitants. Seventy-four percent (74 %, n= 268) of all cancers are found in Stage III and IV. From an imaging point of view, these cancers were presented in an advanced stage, mainly due to their late clinical symptoms and limited access to imaging methods in our country.

  18. Imaging Characteristics and Prevalence of Pancreatic Carcinoma in Kosovo During 2011-2015 - Diagnostic Method as Choice

    PubMed Central

    Dedushi, Kreshnike; Kabashi, Serbeze; Mucaj, Sefedin; Hasbahta, Gazmed; Ramadani, Naser; Hoxhaj, Astrit

    2016-01-01

    Introduction: Pancreatic cancer is the 10thmost common malignancy and the 4thlargest cancer killer in adults. Aim: The purpose of this paper is to evaluate the number of cases presented with pancreatic carcinoma during the years 2011-2015, our experience of the imaging characteristics of pancreatic carcinoma. We evaluated prevalence of the pancreatic cancers, distant metastases and other local infiltration signs among the total cases of the pancreatic cancers diagnosed in the University Clinical Center of Kosovo, with the aim to compare these research findings to similar studies made in the developed countries. This is a retrospective research study done during the period of 2011-2015. Materials and Methodology: This retrospective research study includes 362 patients recently diagnosed with pancreatic cancer, examined in the period of 2011-2015 at the University Clinical Center of Kosovo. The imaging diagnostics are performed with MSCT Sensation 64 Siemens, MSCT Emotion 6 Siemens, and 1.5T MRI Symphony Siemens, biopsy guide with MSCT Sensation 64 Siemens in the Radiologic Clinic of UCCK; while the histopathology diagnostics has been performed in Clinic of Pathology at UCCK and prevalence is taken from the number of cases Reported at the Institute of Oncology Institute of Statistics and NIPH (National Institute of Public Health of Kosovo). Results: Out of a total of the 362 patients diagnosed with pancreas cancer, results is female 39.5% (n=143) and male 61.5% (n=219), report M: F (1: 1.6), 286 cases resulted in head and neck 79 % (n=286), 76 cases resulted in body and tail cancers (21%), distant metastases in first imaging modality were found in(n=155) patients 43 %, local infiltration was found in patients: gastric infiltration 15 % (n=54), duodenal and papilla infiltration 26% (n=94), local infiltration spleen 16% (n=57), local infiltration mesentery 43 % (n= 155), dilated biliary tree 34 % (n=123), regional lymph node infiltration 83 % (n= 300). Out of a total of the 362 patients diagnosed with pancreas cancer, 346 cases resulted > 2 cm and 16 cases resulted < 2 cm and with component cystic was 41.2 % (n = 149), solid with component cystic – necrotic 33% (n= 119), solid 25.7% (n= 93). The prevalence is 19.9: 100,000 inhabitants. Conclusions: Prevalence of carcinoma of the pancreas for 5 years in Kosovo has proved to be prevalence is 19.9: 100,000 inhabitants. Seventy-four percent (74 %, n= 268) of all cancers are found in Stage III and IV. From an imaging point of view, these cancers were presented in an advanced stage, mainly due to their late clinical symptoms and limited access to imaging methods in our country. PMID:27482128

  19. Secure and Resilient Functional Modeling for Navy Cyber-Physical Systems

    DTIC Science & Technology

    2017-05-24

    Functional Modeling Compiler (SCCT) FM Compiler and Key Performance Indicators (KPI) May 2018 Pending. Model Management Backbone (SCCT) MMB Demonstration...implement the agent- based distributed runtime. - KPIs for single/multicore controllers and temporal/spatial domains. - Integration of the model management ...Distributed Runtime (UCI) Not started. Model Management Backbone (SCCT) Not started. Siemens Corporation Corporate Technology Unrestricted

  20. Student Intern Lands Top Prize in National Science Competition | Poster

    Cancer.gov

    By Ashley DeVine, Staff Writer Student intern Sam Pritt’s interest in improving geolocation led him to develop a project that won a top regional prize at the Siemens Competition in Math, Science, and Technology in November. Pritt was awarded a $3,000 college scholarship, and he competed in the national competition in early December.

  1. Making and Missing Connections: Exploring Twitter Chats as a Learning Tool in a Preservice Teacher Education Course

    ERIC Educational Resources Information Center

    Hsieh, Betina

    2017-01-01

    Research on social media use in education indicates that network-based connections can enable powerful teacher learning opportunities. Using a connectivist theoretical framework (Siemens, 2005), this study focuses on secondary teacher candidates (TCs) who completed, archived, and reflected upon 1-hour Twitter chats (N = 39) to explore the promise…

  2. Using Student e-Portfolios to Facilitate Learning Objective Achievements in an Outcome-Based University

    ERIC Educational Resources Information Center

    Tubaishat, Abdallah; Lansari, Azzedine

    2013-01-01

    Several researchers define e-portfolios as a digital collection of students' work accomplished throughout their time of studies in an academic program (Buzzetto-More, 2006; Love, McKean and Gathercoal, 2004; Paulson, Paulson, & Meyer, 1991; Siemens, 2004). E-portfolios can be a rich resource for students and faculty. Students learn to identify…

  3. Connectivism: Learning Theory of the Future or Vestige of the Past?

    ERIC Educational Resources Information Center

    Kop, Rita; Hill, Adrian

    2008-01-01

    Siemens and Downes initially received increasing attention in the blogosphere in 2005 when they discussed their ideas concerning distributed knowledge. An extended discourse has ensued in and around the status of "connectivism" as a learning theory for the digital age. This has led to a number of questions in relation to existing learning…

  4. Connectivity: A Framework for Understanding Effective Language Teaching in Face-to-Face and Online Learning Communities

    ERIC Educational Resources Information Center

    Senior, Rose

    2010-01-01

    This is an exploratory paper that uses the construct of connectivity to examine the nature of effective language teaching and learning in both face-to-face and online learning environments. Broader in scope than Siemens' notion of connectivism, the term connectivity accommodates both transmission approaches to teaching and learning and social…

  5. A Program for Teaching and Learning to Read Professional Texts in a Second/Foreign Language at Siemens AG.

    ERIC Educational Resources Information Center

    O'Flanagan, M. J. R.

    A course was developed for teaching reading comprehension of English technical texts to German speaking professionals. Before proceeding with the course, students are administered a memory test and vocabulary test to determine their initial skill levels in English. The materials used for the course include learner's dictionaries of approximately…

  6. Arsenic Removal from Drinking Water by Coagulation/Filtration U.S. EPA Demonstration Project at Sandusky, MI. Six-Month Evaluation Report

    EPA Science Inventory

    This report documents the activities performed during and the results obtained from the first six months of the EPA arsenic removal technology demonstration project at the City of Sandusky, MI facility. The objectives of the project are to evaluate 1) the effectiveness of Siemen...

  7. 78 FR 20888 - Foreign-Trade Zone (FTZ) 161-Sedgwick County, Kansas; Notification of Proposed Production...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-08

    ...--Sedgwick County, Kansas; Notification of Proposed Production Activity; Siemens Energy, Inc., (Wind Turbine..., 2013. The SEI facilities are used for the production of wind turbine nacelles and hubs. Pursuant to 15..., SEI would be able to choose the duty rates during customs entry procedures that apply to wind turbine...

  8. 77 FR 20782 - Foreign-Trade Zone 161-Sedgwick County, KS; Application for Temporary/Interim Manufacturing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-06

    ... County), Kansas. Under T/IM procedures, Siemens has requested authority to produce wind turbine nacelles..., 8544.49), slip rings (8535.90), cable glands (8536.90), electrical panels/boards (8537.10), lamps (8539... to choose the duty rates during customs entry procedures that apply to wind turbine nacelles and hubs...

  9. Unlocking Funding Potential. Matching Funding to the Community College Mission

    ERIC Educational Resources Information Center

    Pierce, Dennis

    2017-01-01

    When Crystal Bridgeman joined the Siemens Foundation as senior director of workforce development programs in 2014, she pored over research and led conversations about what kind of projects the foundation should invest in to have the biggest impact. Her findings suggested there were a growing number of job opportunities in fields such as advanced…

  10. 77 FR 33213 - Transcontinental Gas Pipe Line Company, LLC; Notice of Request Under Blanket Authorization

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-05

    ... certificate issued in Docket No. CP82-426, for authorization to replace two existing Ansaldo electric motors with two new electric motors at Transco's existing Compressor Station 205 in Princeton, New Jersey... motors and associated variable frequency drives for units 1 and 2 with two new Siemens electric motors...

  11. Concentrating Solar Power Projects - Borges Termosolar | Concentrating

    Science.gov Websites

    CSP plant is hybridized with two biomass units (2 x 22 MW thermal) that supply the required thermal avoiding daily start-up's and shut downs) and therefore, making possible a better use of the thermal block Manufacturer (Model): Siemens (UVAC 2010) HCE Type (Length): Evacuated (4 m) Heat-Transfer Fluid Type: Thermal

  12. ARSENIC REMOVAL FROM DRINKING WATER BY IRON REMOVAL AND ADSORPTIVE MEDIA USEPA DEMONSTRATION PROJECT AT STEWART, MN. SIX-MONTH EVALUATION REPORT

    EPA Science Inventory

    This report documents the activities performed and the results obtained from the first six months of the EPA arsenic removal technology demonstration project at the Stewart, MN facility. The main objective of the project is to evaluate the effectiveness of Siemens¿ Type II AERALA...

  13. German Society for Immunology and Australasian Society for Immunology joint Workshop 3(rd) -4(th) December 2015 - Meeting report.

    PubMed

    Kurts, Christian; Gottschalk, Catherine; Bedoui, Sammy; Heinzel, Susanne; Godfrey, Dale; Enders, Anselm

    2016-02-01

    The German Society for Immunology (DGfI) and the Australasian Society for Immunology (ASI) hosted the first DGfI-ASI joint workshop from December 3-4, 2015 in Canberra, Australia. A delegation of 15 distinguished German immunologists discussed the workshop topic "immune regulation in infections and immune mediated diseases" with the aim to establish new German-Australasian collaborations, discuss new concepts in the field of immune regulation and build a scientific network to create more utilizable resources for excellent (trans-border) immunological research. The workshop was associated with the 45(th) Annual Scientific Meeting of the ASI held from Nov 29-Dec 3, 2015, opening up even more opportunities for finding new collaboration partners. A return meeting will be linked to the annual DGfI meeting that will take place in 2017 in Erlangen. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Comittees

    NASA Astrophysics Data System (ADS)

    2004-10-01

    Fritz Caspers (CERN, Switzerland), Michel Chanel (CERN, Switzerland), Håkan Danared (MSL, Sweden), Bernhard Franzke (GSI, Germany), Manfred Grieser (MPI für Kernphysik, Germany), Dieter Habs (LMU München, Germany), Jeffrey Hangst (University of Aarhus, Denmark), Takeshi Katayama (RIKEN/Univ. Tokyo, Japan), H.-Jürgen Kluge (GSI, Germany), Shyh-Yuan Lee (Indiana University, USA), Rudolf Maier (FZ Jülich, Germany), John Marriner (FNAL, USA), Igor Meshkov (JINR, Russia), Dieter Möhl (CERN, Switzerland), Vasily Parkhomchuk (BINP, Russia), Robert Pollock (Indiana University), Dieter Prasuhn (FZ Jülich, Germany), Dag Reistad (TSL, Sweden), John Schiffer (ANL, USA), Andrew Sessler (LBNL, USA), Alexander Skrinsky (BINP, Russia), Markus Steck (GSI, Germany), Jie Wei (BNL, USA), Andreas Wolf (MPI für Kernphysik, Germany), Hongwei Zhao (IMP, People's Rep. of China).

  15. 75 FR 16827 - Notice of Availability of the Draft Granite Mountain Wind, LLC Wind Energy Generation Project...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-02

    ... wind turbine tower, a maintenance road, and underground electrical and communication lines. Two... to twenty-eight 2.3-megawatt (MW) Siemens wind turbines (or a similar model of wind turbine with a 2... up to 428 feet above the ground. Twenty of the wind turbines would be located on Federal lands...

  16. Plastic scintillation detectors for dose monitoring in digital breast tomosynthesis

    NASA Astrophysics Data System (ADS)

    Antunes, J.; Machado, J.; Peralta, L.; Matela, N.

    2018-01-01

    Plastic scintillators detectors (PSDs) have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. Measurement and analysis of energy dependency were performed on a Siemens Mammomat tomograph for two different peak kilovoltages: 26 kV and 35 kV. Both PSD displayed good linearity for each energy considered and almost no energy dependence.

  17. Renal Perfusion in Scleroderma Patients Assessed by Microbubble-Based Contrast-Enhanced Ultrasound

    PubMed Central

    Kleinert, Stefan; Roll, Petra; Baumgaertner, Christian; Himsel, Andrea; Mueller, Adelheid; Fleck, Martin; Feuchtenberger, Martin; Jenett, Manfred; Tony, Hans-Peter

    2012-01-01

    Objectives: Renal damage is common in scleroderma. It can occur acutely or chronically. Renal reserve might already be impaired before it can be detected by laboratory findings. Microbubble-based contrast-enhanced ultrasound has been demonstrated to improve blood perfusion imaging in organs. Therefore, we conducted a study to assess renal perfusion in scleroderma patients utilizing this novel technique. Materials and Methodology: Microbubble-based contrast agent was infused and destroyed by using high mechanical index by Siemens Sequoia (curved array, 4.5 MHz). Replenishment was recorded for 8 seconds. Regions of interests (ROI) were analyzed in renal parenchyma, interlobular artery and renal pyramid with quantitative contrast software (CUSQ 1.4, Siemens Acuson, Mountain View, California). Time to maximal Enhancement (TmE), maximal enhancement (mE) and maximal enhancement relative to maximal enhancement of the interlobular artery (mE%A) were calculated for different ROIs. Results: There was a linear correlation between the time to maximal enhancement in the parenchyma and the glomerular filtration rate. However, the other parameters did not reveal significant differences between scleroderma patients and healthy controls. Conclusion: Renal perfusion of scleroderma patients including the glomerular filtration rate can be assessed using microbubble-based contrast media. PMID:22670165

  18. [Oxacillin-resistant coagulase-negative Staphylococci bacteremia at a teaching hospital in Santa Maria, State of Rio Grande do Sul, Brazil].

    PubMed

    Rigatti, Fabiane; Tizotti, Maísa Kraulich; Hörner, Rosmari; Domingues, Vanessa Oliveira; Martini, Rosiéli; Mayer, Letícia Eichstaedt; Khun, Fábio Teixeira; de França, Chirles Araújo; da Costa, Mateus Matiuzzi

    2010-01-01

    This study aimed to characterize the prevalence and susceptibility profile to oxacillin-resistant Coagulase-negative Staphylococci strains isolated from blood cultures in a teaching hospital, located in Santa Maria, RS. In addition, different methodologies for phenotypic characterization of mecA-mediated oxacillin resistance were compared with genotypic reference testing. After identification (MicroScan - Siemens), the isolates were tested for antimicrobial sensitivity using disk diffusion and automation (MicroScan - Siemens). The presence of mecA gene was identified by the polymerase chain reaction molecular technique. The most common species was Staphylococcus epidermidis (n=40, 67%). The mecA gene was detected in 54 (90%) strains, while analysis of the sensitivity profiles revealed a high rate of resistance to multiple classes of antimicrobial drugs. However, all isolates were uniformly sensitive to vancomycin and tigecycline. The cefoxitin disk was the phenotypic method that best correlated with the gold standard. Analysis of the clinical significance of CoNS isolated from hemocultures and the precise detection of oxacillin resistance represent decisive factors for the correct choice of antibiotic therapy. Although vancomycin constitutes the normal treatment in most Brazilian hospitals, reduction in its use is recommended.

  19. A bidirectional ACR-NEMA interface between the VA's DHCP Integrated Imaging System and the Siemens-Loral PACS.

    PubMed Central

    Kuzmak, P. M.; Dayhoff, R. E.

    1992-01-01

    There is a wide range of requirements for digital hospital imaging systems. Radiology needs very high resolution black and white images. Other diagnostic disciplines need high resolution color imaging capabilities. Images need to be displayed in many locations throughout the hospital. Different imaging systems within a hospital need to cooperate in order to show the whole picture. At the Baltimore VA Medical Center, the DHCP Integrated Imaging System and a commercial Picture Archiving and Communication System (PACS) work in concert to provide a wide-range of departmental and hospital-wide imaging capabilities. An interface between the DHCP and the Siemens-Loral PACS systems enables patient text and image data to be passed between the two systems. The interface uses ACR-NEMA 2.0 Standard messages extended with shadow groups based on draft ACR-NEMA 3.0 prototypes. A Novell file server, accessible to both systems via Ethernet, is used to communicate all the messages. Patient identification information, orders, ADT, procedure status, changes, patient reports, and images are sent between the two systems across the interface. The systems together provide an extensive set of imaging capabilities for both the specialist and the general practitioner. PMID:1482906

  20. A bidirectional ACR-NEMA interface between the VA's DHCP Integrated Imaging System and the Siemens-Loral PACS.

    PubMed

    Kuzmak, P M; Dayhoff, R E

    1992-01-01

    There is a wide range of requirements for digital hospital imaging systems. Radiology needs very high resolution black and white images. Other diagnostic disciplines need high resolution color imaging capabilities. Images need to be displayed in many locations throughout the hospital. Different imaging systems within a hospital need to cooperate in order to show the whole picture. At the Baltimore VA Medical Center, the DHCP Integrated Imaging System and a commercial Picture Archiving and Communication System (PACS) work in concert to provide a wide-range of departmental and hospital-wide imaging capabilities. An interface between the DHCP and the Siemens-Loral PACS systems enables patient text and image data to be passed between the two systems. The interface uses ACR-NEMA 2.0 Standard messages extended with shadow groups based on draft ACR-NEMA 3.0 prototypes. A Novell file server, accessible to both systems via Ethernet, is used to communicate all the messages. Patient identification information, orders, ADT, procedure status, changes, patient reports, and images are sent between the two systems across the interface. The systems together provide an extensive set of imaging capabilities for both the specialist and the general practitioner.

  1. Prospective gas turbine and combined-cycle units for power engineering (a Review)

    NASA Astrophysics Data System (ADS)

    Ol'khovskii, G. G.

    2013-02-01

    The modern state of technology for making gas turbines around the world and heat-recovery combined-cycle units constructed on their basis are considered. The progress achieved in this field by Siemens, Mitsubishi, General Electric, and Alstom is analyzed, and the objectives these companies set forth for themselves for the near and more distant future are discussed. The 375-MW gas turbine unit with an efficiency of 40% produced by Siemens, which is presently the largest one, is subjected to a detailed analysis. The main specific features of this turbine are that the gas turbine unit's hot-path components have purely air cooling, due to which the installation has enhanced maneuverability. The single-shaft combined-cycle plant constructed on the basis of this turbine has a capacity of 570 MW and efficiency higher than 60%. Programs adopted by different companies for development of new-generation gas turbine units firing synthesis gas and fitted with low-emission combustion chambers and new cooling systems are considered. Concepts of rotor blades for new gas turbine units with improved thermal barrier coatings and composite blades different parts of which are made of materials selected in accordance with the conditions of their operation are discussed.

  2. The Geography of Germany: Lessons for Teaching the Five Themes of Geography.

    ERIC Educational Resources Information Center

    Blankenship, Glen; Tinkler, D. William

    This activity guide contains five lessons. Lesson 1 deals with "Location of Germany on the Earth's Surface" with two activities: (1) "Germany's Location in the World"; and (2) "Germany's Location in Europe." Lesson 2 is on the "Physical and Human Characteristics of Germany" with four activities on: (1)…

  3. Alpha image reconstruction (AIR): A new iterative CT image reconstruction approach using voxel-wise alpha blending

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hofmann, Christian; Sawall, Stefan; Knaup, Michael

    2014-06-15

    Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. Among vendors and researchers, however, there is no consensus of how to best achieve these aims. The general approach is to incorporatea priori knowledge into iterative image reconstruction, for example, by adding additional constraints to the cost function, which penalize variations between neighboring voxels. However, this approach to regularization in general poses a resolution noise trade-off because the stronger the regularization, and thus the noise reduction, the stronger themore » loss of spatial resolution and thus loss of anatomical detail. The authors propose a method which tries to improve this trade-off. The proposed reconstruction algorithm is called alpha image reconstruction (AIR). One starts with generating basis images, which emphasize certain desired image properties, like high resolution or low noise. The AIR algorithm reconstructs voxel-specific weighting coefficients that are applied to combine the basis images. By combining the desired properties of each basis image, one can generate an image with lower noise and maintained high contrast resolution thus improving the resolution noise trade-off. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and low contrast disks is simulated. A filtered backprojection (FBP) reconstruction with a Ram-Lak kernel is used as a reference reconstruction. The results of AIR are compared against the FBP results and against a penalized weighted least squares reconstruction which uses total variation as regularization. The simulations are based on the geometry of the Siemens Somatom Definition Flash scanner. To quantitatively assess image quality, the authors analyze line profiles through resolution patterns to define a contrast factor for contrast-resolution plots. Furthermore, the authors calculate the contrast-to-noise ratio with the low contrast disks and the authors compare the agreement of the reconstructions with the ground truth by calculating the normalized cross-correlation and the root-mean-square deviation. To evaluate the clinical performance of the proposed method, the authors reconstruct patient data acquired with a Somatom Definition Flash dual source CT scanner (Siemens Healthcare, Forchheim, Germany). Results: The results of the simulation study show that among the compared algorithms AIR achieves the highest resolution and the highest agreement with the ground truth. Compared to the reference FBP reconstruction AIR is able to reduce the relative pixel noise by up to 50% and at the same time achieve a higher resolution by maintaining the edge information from the basis images. These results can be confirmed with the patient data. Conclusions: To evaluate the AIR algorithm simulated and measured patient data of a state-of-the-art clinical CT system were processed. It is shown, that generating CT images through the reconstruction of weighting coefficients has the potential to improve the resolution noise trade-off and thus to improve the dose usage in clinical CT.« less

  4. Update on Germany: Now Eastern Germany Gets a Free Press. Special Report SO 8, 1991.

    ERIC Educational Resources Information Center

    Meyn, Hermann

    Since the former East German Communist State--the German Democratic Republic (GDR)--was incorporated into the Federal Republic of Germany, the federal constitution has been valid throughout the whole of Germany, guaranteeing press freedom and ending press censorship in eastern Germany. In October 1989, the GDR had 39 daily newspapers (many…

  5. Sport in Germany. Basis-Info: Social Policy. In-Press.

    ERIC Educational Resources Information Center

    Beitz, Steffen

    This report describes sports in Germany, explaining that sport is part of Germany's culture. Popular sports are enjoyed by both the public and private sector. Germany has a well-developed club and association sector. One in three Germans belongs to a sports organization. A major feature of sport in Germany is its autonomy. Popular sports begin in…

  6. A support vector machine classifier reduces interscanner variation in the HRCT classification of regional disease pattern in diffuse lung disease: Comparison to a Bayesian classifier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Yongjun; Lim, Jonghyuck; Kim, Namkug

    2013-05-15

    Purpose: To investigate the effect of using different computed tomography (CT) scanners on the accuracy of high-resolution CT (HRCT) images in classifying regional disease patterns in patients with diffuse lung disease, support vector machine (SVM) and Bayesian classifiers were applied to multicenter data. Methods: Two experienced radiologists marked sets of 600 rectangular 20 Multiplication-Sign 20 pixel regions of interest (ROIs) on HRCT images obtained from two scanners (GE and Siemens), including 100 ROIs for each of local patterns of lungs-normal lung and five of regional pulmonary disease patterns (ground-glass opacity, reticular opacity, honeycombing, emphysema, and consolidation). Each ROI was assessedmore » using 22 quantitative features belonging to one of the following descriptors: histogram, gradient, run-length, gray level co-occurrence matrix, low-attenuation area cluster, and top-hat transform. For automatic classification, a Bayesian classifier and a SVM classifier were compared under three different conditions. First, classification accuracies were estimated using data from each scanner. Next, data from the GE and Siemens scanners were used for training and testing, respectively, and vice versa. Finally, all ROI data were integrated regardless of the scanner type and were then trained and tested together. All experiments were performed based on forward feature selection and fivefold cross-validation with 20 repetitions. Results: For each scanner, better classification accuracies were achieved with the SVM classifier than the Bayesian classifier (92% and 82%, respectively, for the GE scanner; and 92% and 86%, respectively, for the Siemens scanner). The classification accuracies were 82%/72% for training with GE data and testing with Siemens data, and 79%/72% for the reverse. The use of training and test data obtained from the HRCT images of different scanners lowered the classification accuracy compared to the use of HRCT images from the same scanner. For integrated ROI data obtained from both scanners, the classification accuracies with the SVM and Bayesian classifiers were 92% and 77%, respectively. The selected features resulting from the classification process differed by scanner, with more features included for the classification of the integrated HRCT data than for the classification of the HRCT data from each scanner. For the integrated data, consisting of HRCT images of both scanners, the classification accuracy based on the SVM was statistically similar to the accuracy of the data obtained from each scanner. However, the classification accuracy of the integrated data using the Bayesian classifier was significantly lower than the classification accuracy of the ROI data of each scanner. Conclusions: The use of an integrated dataset along with a SVM classifier rather than a Bayesian classifier has benefits in terms of the classification accuracy of HRCT images acquired with more than one scanner. This finding is of relevance in studies involving large number of images, as is the case in a multicenter trial with different scanners.« less

  7. Comprehensive evaluation of broad-beam transmission of patient supports from three fluoroscopy-guided interventional systems.

    PubMed

    DeLorenzo, Matthew C; Yang, Kai; Li, Xinhua; Liu, Bob

    2018-04-01

    The purpose of the study was to measure, evaluate, and model the broad-beam x-ray transmission of the patient supports from representative modern fluoroscopy-guided interventional systems, for patient skin dose calculation. Broad-beam transmission was evaluated by varying incident angle, kVp, added copper (Cu) filter, and x-ray field size for three fluoroscopy systems: General Electric (GE) Innova 4100 with Omega V table and pad, Siemens Axiom Artis with Siemens tabletop "narrow" (CARD) table and pad, and Siemens Zeego with Trumpf TruSystem 7500 table and pad. Field size was measured on the table using a lead ruler for all setups in this study. Exposure rates were measured in service mode using a calibrated Radcal 10 × 6-60 ion chamber above the patient support at the assumed skin location. Broad-beam transmission factors were calculated by the ratio of air kerma rates measured with and without a patient support in the beam path. First, angle dependency was investigated on the GE system, with the chamber at isocenter, for angles of 0°, 15°, 30°, and 40°, for a variety of kVp, added Cu filters, and for two field sizes (small and large). Second, the broad-beam transmission factor at normal incidence was evaluated for all three fluoroscopes by varying kVp, added Cu filter, and field size (small, medium, and large). An analytical equation was created to fit the data as to maximize R 2 and minimize maximum percentage difference across all measurements for each system. For all patient supports, broad-beam transmission factor increased with field size, kVp, and added Cu filtration and decreased with incident angle. Oblique incidence measurements show that the transmission decreased by about 1%, 3%, and 6% for incident angles of 15°, 30°, and 40°, respectively. The broad-beam transmission factors at 0° for the table and table plus pad ranged from 0.73 to 0.96 and from 0.59 to 0.89, respectively. The GE and Siemens transmission factors were comparable, while the Trumpf transmission factors were the lowest. The data were successfully fitted to a function of angle, field size, kVp, and added Cu filtration using nine parameters, with an average R 2 value of 0.977 and maximum percentage difference of 4.08%. This study evaluated the broad-beam transmission for three representative fluoroscopy systems and their dependency on angle, kVp, added Cu filter, and field size. The comprehensive data provided for patient support transmission will facilitate accurate calculation of peak skin dose (PSD) and may potentially be integrated into real-time and retrospective dose monitoring with access to Radiation Dose Structured Reports (RDSR) and radiation event data. © 2018 American Association of Physicists in Medicine.

  8. The Mother Centers in Germany--Empowerment Strategies for Community Women in Germany.

    ERIC Educational Resources Information Center

    Jaeckel, Monika

    Mother Centers are a grassroots self-help movement in Germany that help stay-at-home mothers break through the isolation they experience in German society when they have children and are not available for full-time employment. There are about 300 mother center projects currently in Germany, including 40 in the former East Germany. The programs…

  9. Conference scene: DGVS spring conference 2009.

    PubMed

    Kolligs, Frank Thomas

    2009-10-01

    The 3rd annual DGVS Spring Conference of the German Society for Gastroenterology (Deutsche Gesellschaft für Verdauungs- und Stoffwechselkrankheiten) was held at the Seminaris Campus Hotel in Berlin, Germany, on 8-9 May, 2009. The conference was organized by Roland Schmid and Matthias Ebert from the Technical University of Munich, Germany. The central theme of the meeting was 'translational gastrointestinal oncology: towards personalized medicine and individualized therapy'. The conference covered talks on markers for diagnosis, screening and surveillance of colorectal cancer, targets for molecular therapy, response prediction in clinical oncology, development and integration of molecular imaging in gastrointestinal oncology and translational research in clinical trial design. Owing to the broad array of topics and limitations of space, this article will focus on biomarkers, response prediction and the integration of biomarkers into clinical trials. Presentations mentioned in this summary were given by Matthias Ebert (Technical University of Munich, Germany), Esmeralda Heiden (Epigenomics, Berlin, Germany), Frank Kolligs (University of Munich, Germany), Florian Lordick (University of Heidelberg, Germany), Hans Jorgen Nielsen (University of Copenhagen, Denmark), Anke Reinacher-Schick (University of Bochum, Germany), Christoph Röcken (University of Berlin, Germany), Wolff Schmiegel (University of Bochum, Germany) and Thomas Seufferlein (University of Halle, Germany).

  10. Influence of 4-week multi-strain probiotic administration on resting-state functional connectivity in healthy volunteers.

    PubMed

    Bagga, Deepika; Aigner, Christoph Stefan; Reichert, Johanna Louise; Cecchetto, Cinzia; Fischmeister, Florian Ph S; Holzer, Peter; Moissl-Eichinger, Christine; Schöpf, Veronika

    2018-05-30

    Experimental investigations in rodents have contributed significantly to our current understanding of the potential importance of the gut microbiome and brain interactions for neurotransmitter expression, neurodevelopment, and behaviour. However, clinical evidence to support such interactions is still scarce. The present study used a double-blind, randomized, pre- and post-intervention assessment design to investigate the effects of a 4-week multi-strain probiotic administration on whole-brain functional and structural connectivity in healthy volunteers. Forty-five healthy volunteers were recruited for this study and were divided equally into three groups (PRP: probiotic, PLP: placebo, and CON: control). All the participants underwent resting-state functional MRI and diffusion MRI brain scans twice during the course of study, at the beginning (time point 1) and after 4 weeks (time point 2). MRI data were acquired using a 3T whole-body MR system (Magnetom Skyra, Siemens, Germany). Functional connectivity (FC) changes were observed in the default mode network (DMN), salience network (SN), and middle and superior frontal gyrus network (MFGN) in the PRP group as compared to the PLP and CON groups. PRP group showed a significant decrease in FC in MFGN (in frontal pole and frontal medial cortex) and in DMN (in frontal lobe) as compared to CON and PLP groups, respectively. Further, significant increase in FC in SN (in cingulate gyrus and precuneus cortex) was also observed in PRP group as compared to CON group. The significance threshold was set to p < 0.05 FWE corrected. No significant structural differences were observed between the three groups. This work provides new insights into the role of a multi-strain probiotic administration in modulating the behaviour, which is reflected as changes in the FC in healthy volunteers. This study motivates future investigations into the role of probiotics in context of major depression and stress disorders.

  11. Pediatric Chest and Abdominopelvic CT: Organ Dose Estimation Based on 42 Patient Models

    PubMed Central

    Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Paulson, Erik K.; Frush, Donald P.

    2014-01-01

    Purpose To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. Materials and Methods The institutional review board approved this HIPAA–compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0–16 years; weight range, 2–80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDIvol). The relationships between CTDIvol-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. Results For organs within the image coverage, CTDIvol-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R2 > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%–32%) mainly because of the effect of overranging. Conclusion It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDIvol. These CTDIvol-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. © RSNA, 2013 PMID:24126364

  12. SU-E-J-240: Development of a Novel 4D MRI Sequence for Real-Time Liver Tumor Tracking During Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhuang, L; Burmeister, J; Ye, Y

    2015-06-15

    Purpose: To develop a Novel 4D MRI Technique that is feasible for realtime liver tumor tracking during radiotherapy. Methods: A volunteer underwent an abdominal 2D fast EPI coronal scan on a 3.0T MRI scanner (Siemens Inc., Germany). An optimal set of parameters was determined based on image quality and scan time. A total of 23 slices were scanned to cover the whole liver in the test scan. For each scan position, the 2D images were retrospectively sorted into multiple phases based on breathing signal extracted from the images. Consequently the 2D slices with same phase numbers were stacked to formmore » one 3D image. Multiple phases of 3D images formed the 4D MRI sequence representing one breathing cycle. Results: The optimal set of scan parameters were: TR= 57ms, TE= 19ms, FOV read= 320mm and flip angle= 30°, which resulted in a total scan time of 14s for 200 frames (FMs) per slice and image resolution of (2.5mm,2.5mm,5.0mm) in three directions. Ten phases of 3D images were generated, each of which had 23 slices. Based on our test scan, only 100FMs were necessary for the phase sorting process which may lower the scan time to 7s/100FMs/slice. For example, only 5 slices/35s are necessary for a 4D MRI scan to cover liver tumor size ≤ 2cm leading to the possibility of tumor trajectory tracking every 35s during treatment. Conclusion: The novel 4D MRI technique we developed can reconstruct a 4D liver MRI sequence representing one breathing cycle (7s/ slice) without an external monitor. This technique can potentially be used for real-time liver tumor tracking during radiotherapy.« less

  13. Using a whole-body 31P birdcage transmit coil and 16-element receive array for human cardiac metabolic imaging at 7T

    PubMed Central

    Dragonu, Iulius; Almujayyaz, Salam; Batzakis, Alex; Young, Liam A. J.; Purvis, Lucian A. B.; Clarke, William T.; Wichmann, Tobias; Lanz, Titus; Neubauer, Stefan; Robson, Matthew D.; Klomp, Dennis W. J.; Rodgers, Christopher T.

    2017-01-01

    Purpose Cardiac phosphorus magnetic resonance spectroscopy (31P-MRS) provides unique insight into the mechanisms of heart failure. Yet, clinical applications have been hindered by the restricted sensitivity of the surface radiofrequency-coils normally used. These permit the analysis of spectra only from the interventricular septum, or large volumes of myocardium, which may not be meaningful in focal disease. Löring et al. recently presented a prototype whole-body (52 cm diameter) transmit/receive birdcage coil for 31P at 7T. We now present a new, easily-removable, whole-body 31P transmit radiofrequency-coil built into a patient-bed extension combined with a 16-element receive array for cardiac 31P-MRS. Materials and methods A fully-removable (55 cm diameter) birdcage transmit coil was combined with a 16-element receive array on a Magnetom 7T scanner (Siemens, Germany). Electro-magnetic field simulations and phantom tests of the setup were performed. In vivo maps of B1+, metabolite signals, and saturation-band efficiency were acquired across the torsos of eight volunteers. Results The combined (volume-transmit, local receive array) setup increased signal-to-noise ratio 2.6-fold 10 cm below the array (depth of the interventricular septum) compared to using the birdcage coil in transceiver mode. The simulated coefficient of variation for B1+ of the whole-body coil across the heart was 46.7% (surface coil 129.0%); and the in vivo measured value was 38.4%. Metabolite images of 2,3-diphosphoglycerate clearly resolved the ventricular blood pools, and muscle tissue was visible in phosphocreatine (PCr) maps. Amplitude-modulated saturation bands achieved 71±4% suppression of phosphocreatine PCr in chest-wall muscles. Subjects reported they were comfortable. Conclusion This easy-to-assemble, volume-transmit, local receive array coil combination significantly improves the homogeneity and field-of-view for metabolic imaging of the human heart at 7T. PMID:29073228

  14. Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devices.

    PubMed

    Birschmann, Ingvild; Dittrich, Marcus; Eller, Thomas; Wiegmann, Bettina; Reininger, Armin J; Budde, Ulrich; Strüber, Martin

    2014-01-01

    Thromboembolic and bleeding events in patients with a left ventricular assist device (LVAD) are still a major cause of complications. Therefore, the balance between anti-coagulant and pro-coagulant factors needs to be tightly controlled. The principle hypothesis of this study is that different pump designs may have an effect on hemolysis and activation of the coagulation system. Referring to this, the HeartMate II (HMII; Thoratec Corp, Pleasanton, CA) and the HeartWare HVAD (HeartWare International Inc, Framingham, MA) were investigated. For 20 patients with LVAD support (n = 10 each), plasma coagulation, full blood count, and clinical chemistry parameters were measured. Platelet function was monitored using platelet aggregometry, platelet function analyzer-100 system ( Siemens, Marburg, Germany), vasodilator-stimulated phosphoprotein phosphorylation assay, immature platelet fraction, platelet-derived microparticles, and von Willebrand diagnostic. Acquired von Willebrand syndrome could be detected in all patients. Signs of hemolysis, as measured by lactate dehydrogenase levels (mean, 470 U/liter HMII, 250 U/liter HVAD; p < 0.001), were more pronounced in the HMII patients. In contrast, D-dimer analysis indicated a significantly higher activation of the coagulation system in HVAD patients (mean, 0.94 mg/liter HMII, 2.01 mg/liter HVAD; p < 0.01). The efficacy of anti-platelet therapy using clopidogrel was not sufficient in more than 50% of the patients. Our results support the finding that all patients with rotary blood pumps suffered from von Willebrand syndrome. In addition, a distinct footprint of effects on hemolysis and the coagulation system can be attributed to different devices. As a consequence, the individual status of the coagulation system needs to be controlled in long-term patients. © 2013 Published by International Society for the Heart and Lung Transplantation on behalf of International Society for Heart and Lung Transplantation.

  15. [Observing the density increase curve after intravenous contrast medium administration using a bolus triggering system: a method for detection cardiovascular disorders?].

    PubMed

    Stückle, C A; Kickuth, R; Kirchner, E M; Liermann, D; Kirchner, J

    2002-06-01

    Recently bolus tracking systems were developed to improve the timing of intravenous contrast media application in helical computed tomography. We investigated the benefit of this new method as a parameter of the cardiac function. Retrospective analysis of 64 patients which incidentally underwent bolus triggered contrast enhanced helical CT and invasive investigation of the heart within one week. All examinations were performed on the CT scanner Somatom Plus 4 Volume Zoom (Siemens Corp., Forchheim, Germany) using the C.A.R.E. Bolus software. This performs repetitive low-dose test scans (e.g. for the abdomen: 140 kV, 20 mA, Tl 0.5 s) and measures the Hounsfield attenuation (increase over the baseline) in a preselected region of interest. The displayed increase of vascular density over the time after peripheral contrast media injection (75 ml lopromid (300 mg/ml), 2 ml/s) was categorised to three types: (a) rapid increase, (b) deceleration before a 100 HE threshold was reached and (c) one or more peaks. The findings of the invasive investigation of the heart were correlated to the findings of the bolus-tracking measurements. The examinations were categorized as follows: 19 type A, 34 type B, 11 type C. We found a high significant correlation between the type of the Hounsfield attenuation and systolic pressure in the left ventricle. There was no correlation between the type of the Hounsfield attenuation and the diastolic pressure in the left ventricle, the pressures related to the right ventricle or the ejection fraction. The bolus-tacking system showed a sensitivity of 53, a specificity of 82, an accuracy of 70%, a positive predictive value of 70% and a negative predictive value of 70% in detection of left heart failure. The bolus tracking system C.A.R.E.-bolus often shows atypical Hounsfield attenuation in cases of cardiac failure but is not suitable as a screening method of the cardiopulmonary function.

  16. SU-F-T-200: Dosimetric Variation of Organs at Risk for Recurrent Nasopharyngeal Carcinoma (rNPC) Patients Treated by Carbon Ion Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, W; Sheng, Y; Shahnazi, K

    2016-06-15

    Purpose: Investigate the factors which affect the doses of organs at risk (OARs) for head and neck carbon ion therapy. Methods: Ten locally recurrent nasopharyngeal carcinoma cases with similar prescriptions were selected. All patients’ organs at risk (OARs) as well as CTVs were contoured by an experienced physician. Carbon ion treatment plans were created using a Syngo treatment planning system (Siemens, Germany). The CTVs were expanded to make optimized target volumes (OTVs) by considering treatment uncertainties and OAR protections. All plans were reviewed by this physician to be clinically acceptable. The OTV was expanded an additional 3mm to define themore » volume where beam spots could be put. A volume was also drawn 6 mm around the OTV to approximate the 50 % dose volume. The volumes where the OARs overlapped the OTV + 3 mm and OTV + 6 mm volumes, termed residual volumes, were then calculated. Results: The residual volumes within OTV + 3 mm were directly related to the OAR maximum dose. The percentage of the residual volume within the OTV + 6 mm with respect to the OAR volume was strongly related to the OAR mean doses. OAR mean doses also were affected by the beam setups. For example, if the OARs were in the beam entrance, the superior beams would sharply decrease the mean doses of the OARs hit by the lateral beams while increasing the mean doses of the OARs hit by the superior beam; the mean dose of the OARs which were hit by higher weight beams would be higher than the OARs hit by lower weight beams. Conclusion: Physicians should be cautious when contouring OARs, especially those close to CTVs and sensitive to large doses. Planners should set the OTV and beam parameters properly in order to save the OARs.« less

  17. Primary stability of a hybrid self-tapping implant compared to a cylindrical non-self-tapping implant with respect to drilling protocols in an ex vivo model.

    PubMed

    Toyoshima, Takeshi; Wagner, Wilfried; Klein, Marcus Oliver; Stender, Elmar; Wieland, Marco; Al-Nawas, Bilal

    2011-03-01

    Modifications of implant design have been intending to improve primary stability. However, little is known about investigation of a hybrid self-tapping implant on primary stability. The aims of this study were to evaluate the primary stability of two hybrid self-tapping implants compared to one cylindrical non-self-tapping implant, and to elucidate the relevance of drilling protocols on primary stability in an ex vivo model. Two types of hybrid self-tapping implants (Straumann® Bone Level implant [BL], Straumann® Tapered Effect implant [TE]) and one type of cylindrical non-self-tapping implant (Straumann® Standard Plus implant [SP]) were investigated in the study. In porcine iliac cancellous bones, 10 implants each were inserted either using standard drilling or under-dimensioned drilling protocol. The evaluation of implant-bone interface stability was carried out by records of maximum insertion torque, the Periotest® (Siemens, Bensheim, Germany), the resonance frequency analysis (RFA), and the push-out test. In each drilling group, the maximum insertion torque values of BL and TE were significantly higher than SP (p=.014 and p=.047, respectively). In each group, the Periotest values of TE were significantly lower than SP (p=.036 and p=.033, respectively). The Periotest values of BL and TE were significantly lower in the group of under-dimensioned drilling than standard drilling (p=.002 and p=.02, respectively). In the RFA, no statistical significances were found in implants between two groups and between implants in each group. In each group, the push-out values of BL and TE were significantly higher than SP (p=.006 and p=.049, respectively). Hybrid self-tapping implants could achieve a high primary stability which predicts them for use in low-density bone. However, there is still a debate to clarify the influence of under-dimensioned drilling on primary stability. © 2009, Copyright the Authors. Journal Compilation © 2011, Wiley Periodicals, Inc.

  18. A study on a pedicle-screw-based reduction method for artificially reduced artifacts

    NASA Astrophysics Data System (ADS)

    Kim, Hyun-Ju; Lee, Hae-Kag; Cho, Jae-Hwan

    2017-09-01

    The purpose of this study is a quantitative analysis of the degree of the reduction of the artifacts that are induced by pedicle screws through the application of the recently developed iterative metallic artifact reduction (I MAR) software. Screw-type implants that are composed of 4.5 g/cm3 titanium (Ti) with an approximate average computed tomography (CT) value of 6500 Hounsfield units (HUs) that are used for the treatment of spinal diseases were placed in paraffin, a tissueequivalent material, and then dried. After the insertion, the scanning conditions were fixed as 120 kVp and 250 mA using multidetector computed tomography (MDCT) (Enlarge, Siemens, Germany). The slice thickness and the increment were set at the fields of view (FOVs) of 3 mm and 120 mm, respectively; the pitch is 0.8; the rotation time is 1 s; and the I MAR software was applied to the raw data of the acquired images to compare the CT-value changes of the posterior images. When the I MAR software was applied to animal vertebrae, it was possible to reduce the 65.7% image loss of the black-hole-effect image through the application of the I MAR software. When the I MAR image loss (%) was compared with the white-streak-effect image, the high-intensity image type with the white-streak effect could be reduced by 91.34% through the application of the I MAR software. In conclusion, a metal artifact that is due to a high-density material can be reduced more effectively when the I MAR algorithm is applied compared with that from the application of the conventional MAR algorithm. The I MAR can provide information on the various tissues that form around the artifact and the reduced metal structures, which can be helpful for radiologists and clinicians in their determination of an accurate diagnosis.

  19. Task-based image quality evaluation of iterative reconstruction methods for low dose CT using computer simulations

    NASA Astrophysics Data System (ADS)

    Xu, Jingyan; Fuld, Matthew K.; Fung, George S. K.; Tsui, Benjamin M. W.

    2015-04-01

    Iterative reconstruction (IR) methods for x-ray CT is a promising approach to improve image quality or reduce radiation dose to patients. The goal of this work was to use task based image quality measures and the channelized Hotelling observer (CHO) to evaluate both analytic and IR methods for clinical x-ray CT applications. We performed realistic computer simulations at five radiation dose levels, from a clinical reference low dose D0 to 25% D0. A fixed size and contrast lesion was inserted at different locations into the liver of the XCAT phantom to simulate a weak signal. The simulated data were reconstructed on a commercial CT scanner (SOMATOM Definition Flash; Siemens, Forchheim, Germany) using the vendor-provided analytic (WFBP) and IR (SAFIRE) methods. The reconstructed images were analyzed by CHOs with both rotationally symmetric (RS) and rotationally oriented (RO) channels, and with different numbers of lesion locations (5, 10, and 20) in a signal known exactly (SKE), background known exactly but variable (BKEV) detection task. The area under the receiver operating characteristic curve (AUC) was used as a summary measure to compare the IR and analytic methods; the AUC was also used as the equal performance criterion to derive the potential dose reduction factor of IR. In general, there was a good agreement in the relative AUC values of different reconstruction methods using CHOs with RS and RO channels, although the CHO with RO channels achieved higher AUCs than RS channels. The improvement of IR over analytic methods depends on the dose level. The reference dose level D0 was based on a clinical low dose protocol, lower than the standard dose due to the use of IR methods. At 75% D0, the performance improvement was statistically significant (p < 0.05). The potential dose reduction factor also depended on the detection task. For the SKE/BKEV task involving 10 lesion locations, a dose reduction of at least 25% from D0 was achieved.

  20. Fbis report. Science and technology: Economic review, September 19, 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-09-19

    ;Partial Contents: Germany: Braunschweig University Tests Organic Semiconductors; France: Ariane-5 Tests Suspended; First Tests in Euro-Russian RECORD Rocket Engine Program; France: Renault`s Multi-Model Assembly Line Presented; Germany: New High Speed Trains Under Development; France: Matra Test Drone, Missile Systems; France: Experimental Project for Automobile Recycling; Germany: Survey of Flexible Manufacturing Developments; Germany: Heinrich Hertz Institute Produces Polymer-Based Circuit; French Firms Introduce Computerized Control Room for Nuclear Plants; German Machine Tool Industry Calls for Information Technology Projects; Germany: R&D Achievements in Digital HDTV Reported; Hungary: Secondary Telecommunications Networks Described; EU: Mergers in Pharmaceutical Industry Reported; SGS-Thomson Business Performance Analyzed; Germany`s Siemensmore » Invest Heavily in UK Semiconductor Plant.« less

  1. Wind Turbine Blade CAD Models Used as Scaffolding Technique to Teach Design Engineers

    ERIC Educational Resources Information Center

    Irwin, John

    2013-01-01

    The Siemens PLM CAD software NX is commonly used for designing mechanical systems, and in complex systems such as the emerging area of wind power, the ability to have a model controlled by design parameters is a certain advantage. Formula driven expressions based on the amount of available wind in an area can drive the amount of effective surface…

  2. JPRS Report, Science & Technology: Europe

    DTIC Science & Technology

    1989-07-17

    Construction of First Technological Park Begins [Barcelona REVISTA DE ROBOTICA , Mar 89] .... 8 European Firms Strive To Increase Competitiveness 8...Madrid University, Siemens Cooperation on AI Project Reported [Barcelona REVISTA DE ROBOTICA , Mar 89] .....: 21 ENERGY FRG’s Kohl Outlines...Park Begins 36980224b Barcelona REVISTA DE ROBOTICA in Spanish Mär 89 p 24 [Text] Telescincro, Inc., laid the cornerstone of its new factory and

  3. Wind Power Innovation Enables Shift to Utility-Scale - Continuum Magazine

    Science.gov Websites

    the 1930s, a farmer in South Dakota built a small wind turbine on his farm, generating enough enough electricity to power thousands of homes. Aerial photo of large wind turbine with mountains in the background. Aerial view of the Siemens utility-scale wind turbine at the National Wind Technology Center

  4. PLCs used in smart home control

    NASA Astrophysics Data System (ADS)

    Barz, C.; Deaconu, S. I.; Latinovic, T.; Berdie, A.; Pop-Vadean, A.; Horgos, M.

    2016-02-01

    This paper presents the realization of a smart home automation using Siemens PLCs. The smart home interface is realized using the HMI Weintek eMT3070a touchscreen, which shows the window for controlling and monitoring the lighting, room temperature, irrigation systems, swimming pool, etc. By using PLCs, the smart home can be controlled via Ethernet and it can be programmed to the needs of tenants.

  5. Special Inspector General for Iraq Reconstruction (SIGIR): Moving Beyond the IRRF

    DTIC Science & Technology

    2007-04-30

    SCREEN 60” INSTANT CINEMA PROJECTION SCREEN ITEM# 20022351 SYTLES#: 60300 $12,750.00 $12,750.00 $0.00 CEFMS ISFF2 4/2/2007 3800 W91GY0-07-M-0163-NA-4...Generation: Baiji Gas 3&4 (318 MW – consisting of two Siemens 159 MW generators) Start Date: 11/24/2003 26 Back-Up Generators: 200 MW ( Japanese

  6. SU-F-J-71: Improving CT Quality for Radiation Therapy Planning and Delivery Guidance Using a Non-Linear Contrast Enhancement Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Noid, G; Tai, A; Li, X

    2016-06-15

    Purpose: Advanced image post-processing techniques which enhance soft-tissue contrast in CT have not been widely employed for RT planning or delivery guidance. The purpose of this work is to assess the soft-tissue contrast enhancement from non-linear contrast enhancing filters and its impact in RT. The contrast enhancement reduces patient alignment uncertainties. Methods: Non-linear contrast enhancing methods, such as Best Contrast (Siemens), amplify small differences in X-ray attenuation between two adjacent structure without significantly increasing noise. Best Contrast (BC) separates a CT into two frequency bands. The low frequency band is modified by a non-linear scaling function before recombination with themore » high frequency band. CT data collected using a CT-on-rails (Definition AS Open, Siemens) during daily CT-guided RT for 6 prostate cancer patients and an image quality phantom (The Phantom Laboratory) were analyzed. Images acquired with a standard protocol (120 kVp, 0.6 pitch, 18 mGy CTDIvol) were processed before comparison to the unaltered images. Contrast and noise were measured in the the phantom. Inter-observer variation was assessed by placing prostate contours on the 12 CT study sets, 6 enhanced and 6 unaltered, in a blinded study involving 8 observers. Results: The phantom data demonstrate that BC increased the contrast between the 1.0% supra-slice element and the background substrate by 46.5 HU while noise increased by only 2.3 HU. Thus the contrast to noise ratio increased from 1.28 to 6.71. Furthermore, the variation in centroid position of the prostate contours was decreased from 1.3±0.4 mm to 0.8±0.3 mm. Thus the CTV-to-PTV margin was reduced by 1.1 mm. The uncertainty in delineation of the prostate/rectum edge decreased by 0.5 mm. Conclusion: As demonstrated in phantom and patient scans the BC filter accentuates soft-tissue contrast. This enhancement leads to reduced inter-observer variation, which should improve RT planning and delivery. Supported by Siemens.« less

  7. MO-E-17A-08: Attenuation-Based Size Adjusted, Scanner-Independent Organ Dose Estimates for Head CT Exams: TG 204 for Head CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMillan, K; Bostani, M; Cagnon, C

    Purpose: AAPM Task Group 204 described size specific dose estimates (SSDE) for body scans. The purpose of this work is to use a similar approach to develop patient-specific, scanner-independent organ dose estimates for head CT exams using an attenuation-based size metric. Methods: For eight patient models from the GSF family of voxelized phantoms, dose to brain and lens of the eye was estimated using Monte Carlo simulations of contiguous axial scans for 64-slice MDCT scanners from four major manufacturers. Organ doses were normalized by scannerspecific 16 cm CTDIvol values and averaged across all scanners to obtain scanner-independent CTDIvol-to-organ-dose conversion coefficientsmore » for each patient model. Head size was measured at the first slice superior to the eyes; patient perimeter and effective diameter (ED) were measured directly from the GSF data. Because the GSF models use organ identification codes instead of Hounsfield units, water equivalent diameter (WED) was estimated indirectly. Using the image data from 42 patients ranging from 2 weeks old to adult, the perimeter, ED and WED size metrics were obtained and correlations between each metric were established. Applying these correlations to the GSF perimeter and ED measurements, WED was calculated for each model. The relationship between the various patient size metrics and CTDIvol-to-organ-dose conversion coefficients was then described. Results: The analysis of patient images demonstrated the correlation between WED and ED across a wide range of patient sizes. When applied to the GSF patient models, an exponential relationship between CTDIvol-to-organ-dose conversion coefficients and the WED size metric was observed with correlation coefficients of 0.93 and 0.77 for the brain and lens of the eye, respectively. Conclusion: Strong correlation exists between CTDIvol normalized brain dose and WED. For the lens of the eye, a lower correlation is observed, primarily due to surface dose variations. Funding Support: Siemens-UCLA Radiology Master Research Agreement; Disclosures - Michael McNitt-Gray: Institutional Research Agreement, Siemens AG; Research Support, Siemens AG; Consultant, Flaherty Sensabaugh Bonasso PLLC; Consultant, Fulbright and Jaworski.« less

  8. SU-E-T-508: End to End Testing of a Prototype Eclipse Module for Planning Modulated Arc Therapy On the Siemens Platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, L; Sarkar, V; Spiessens, S

    2014-06-01

    Purpose: The latest clinical implementation of the Siemens Artiste linac allows for delivery of modulated arcs (mARC) using full-field flattening filter free (FFF) photon beams. The maximum doserate of 2000 MU/min is well suited for high dose treatments such as SBRT. We tested and report on the performance of a prototype Eclipse TPS module supporting mARC capability on the Artiste platform. Method: our spine SBRT patients originally treated with 12/13 field static-gantry IMRT (SGIMRT) were chosen for this study. These plans were designed to satisfy RTOG0631 guidelines with a prescription of 16Gy in a single fraction. The cases were re-plannedmore » as mARC plans in the prototype Eclipse module using the 7MV FFF beam and required to satisfy RTOG0631 requirements. All plans were transferred from Eclipse, delivered on a Siemens Artiste linac and dose-validated using the Delta4 system. Results: All treatment plans were straightforwardly developed, in timely fashion, without challenge or inefficiency using the prototype module. Due to the limited number of segments in a single arc, mARC plans required 2-3 full arcs to yield plan quality comparable to SGIMRT plans containing over 250 total segments. The average (3%/3mm) gamma pass-rate for all arcs was 98.5±1.1%, thus demonstrating both excellent dose prediction by the AAA dose algorithm and excellent delivery fidelity. Mean delivery times for the mARC plans(10.5±1.7min) were 50-70% lower than the SGIMRT plans(26±2min), with both delivered at 2000 MU/min. Conclusion: A prototype Eclipse module capable of planning for Burst Mode modulated arc delivery on the Artiste platform has been tested and found to perform efficiently and accurately for treatment plan development and delivered-dose prediction. Further investigation of more treatment sites is being carried out and data will be presented.« less

  9. WE-FG-207B-09: Experimental Assessment of Noise and Spatial Resolution in Virtual Non-Contrast Dual-Energy CT Images Across Multiple Patient Sizes and CT Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montoya, J; Ferrero, A; Yu, L

    Purpose: To investigate the noise and spatial resolution properties of virtual non-contrast (VNC) dual-energy CT images compared to true non-contrast (TNC) images across multiple patient sizes and CT systems. Methods: Torso-shaped water phantoms with lateral widths of 25, 30, 35, 40 and 45 cm and a high resolution bar pattern phantom (Catphan CTP528) were scanned using 2nd and 3rd generation dual-source CT systems (Scanner A: Somatom Definition Flash, Scanner B: Somatom Force, Siemens Healthcare) in dual-energy scan mode with the same radiation dose for a given phantom size. Tube potentials of 80/Sn140 and 100/Sn140 on Scanner A and 80/Sn150, 90/Sn150more » and 100/Sn150 on Scanner B were evaluated to examine the impact of spectral separation. Images were reconstructed using a medium sharp quantitative kernel (Qr40), 1.0-mm thickness, 1.0-mm interval and 20 cm field of view. Mixed images served as TNC images. VNC images were created using commercial software (Virtual Unenhanced, Syngo VIA Version VA30, Siemens Healthcare). The noise power spectrum (NPS), area under the NPS, peak frequency of the NPS and image noise were measured for every phantom size and tube potential combination in TNC and VNC images. Results were compared within and between CT systems. Results: Minimal shift in NPS peak frequencies was observed in VNC images compared to TNC for NPS having pronounced peaks. Image noise and area under the NPS were higher in VNC images compared to TNC images across all tube potentials and for scanner A compared to scanner B. Limiting spatial resolution was deemed to be identical between VNC and TNC images. Conclusion: Quantitative assessment of image quality in VNC images demonstrated higher noise but equivalent spatial resolution compared to TNC images. Decreased noise was observed in the 3rd generation dual-source CT system for tube potential pairs having greater spectral separation. Dr. McCollough receives research support from Siemens Healthcare.« less

  10. Methods for CT automatic exposure control protocol translation between scanner platforms.

    PubMed

    McKenney, Sarah E; Seibert, J Anthony; Lamba, Ramit; Boone, John M

    2014-03-01

    An imaging facility with a diverse fleet of CT scanners faces considerable challenges when propagating CT protocols with consistent image quality and patient dose across scanner makes and models. Although some protocol parameters can comfortably remain constant among scanners (eg, tube voltage, gantry rotation time), the automatic exposure control (AEC) parameter, which selects the overall mA level during tube current modulation, is difficult to match among scanners, especially from different CT manufacturers. Objective methods for converting tube current modulation protocols among CT scanners were developed. Three CT scanners were investigated, a GE LightSpeed 16 scanner, a GE VCT scanner, and a Siemens Definition AS+ scanner. Translation of the AEC parameters such as noise index and quality reference mAs across CT scanners was specifically investigated. A variable-diameter poly(methyl methacrylate) phantom was imaged on the 3 scanners using a range of AEC parameters for each scanner. The phantom consisted of 5 cylindrical sections with diameters of 13, 16, 20, 25, and 32 cm. The protocol translation scheme was based on matching either the volumetric CT dose index or image noise (in Hounsfield units) between two different CT scanners. A series of analytic fit functions, corresponding to different patient sizes (phantom diameters), were developed from the measured CT data. These functions relate the AEC metric of the reference scanner, the GE LightSpeed 16 in this case, to the AEC metric of a secondary scanner. When translating protocols between different models of CT scanners (from the GE LightSpeed 16 reference scanner to the GE VCT system), the translation functions were linear. However, a power-law function was necessary to convert the AEC functions of the GE LightSpeed 16 reference scanner to the Siemens Definition AS+ secondary scanner, because of differences in the AEC functionality designed by these two companies. Protocol translation on the basis of quantitative metrics (volumetric CT dose index or measured image noise) is feasible. Protocol translation has a dependency on patient size, especially between the GE and Siemens systems. Translation schemes that preserve dose levels may not produce identical image quality. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  11. TU-EF-204-08: Dose Efficiency of Added Beam-Shaping Filter with Varied Attenuation Levels in Lung-Cancer Screening CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, C; Yu, L; Vrieze, T

    Purpose: Added filtration such as tin filter has the potential to improve dose efficiency of x-ray beam in lung-cancer screening CT. However, dose efficiency with added beam filtration is highly dependent on patient attenuation level. In this phantom study, we evaluated the image quality at different tube voltages with and without added tin filter when attenuation level varies. Methods: A 30 x 20 cm anthropomorphic thorax phantom with three added extension rings were used to simulate small (S), medium (M), large (L), and extra-large (XL) adult patients. These phantoms were scanned on a 192-slice CT scanner (Force, Siemens) at 100more » and 120kV without tin filtration, and 100 and 150 kV with tin filtration (100Sn and 150Sn), at multiple dose levels at each kV. Images were reconstructed using iterative reconstruction (ADMIRE, Siemens). Radiation dose was measured with a 0.6 cc ion chamber in the middle and peripheral areas of the phantom. Image quality was assessed using mean image noise at uniform areas in the central region and lung. Radiation dose that is required for each kV to match the noise in a routine lung-cancer CT screening technique (120kV, 25 quality reference mAs) was calculated. Results: At each of the four phantom sizes, 100Sn had the lowest noise in both soft tissue and lung. Compared with 120 kV, 100Sn saved 39%–60% dose for the same noise, depending on phantom size. For the XL phantom (50 by 40 cm), 150Sn provided images with the least beam-hardening artifact in peripheral region. Conclusion: For thoracic CT, added tin filtration can provide considerable dose reduction compared with 120 kV. 100Sn provides better dose efficiencies for all phantom sizes, while 150Sn provides better image quality in peripheral region for extra-large patients. Drs.Joel G. Fletcher and Cynthia H. McCollough receive research support from Siemens Healthcare.« less

  12. Objective performance assessment of five computed tomography iterative reconstruction algorithms.

    PubMed

    Omotayo, Azeez; Elbakri, Idris

    2016-11-22

    Iterative algorithms are gaining clinical acceptance in CT. We performed objective phantom-based image quality evaluation of five commercial iterative reconstruction algorithms available on four different multi-detector CT (MDCT) scanners at different dose levels as well as the conventional filtered back-projection (FBP) reconstruction. Using the Catphan500 phantom, we evaluated image noise, contrast-to-noise ratio (CNR), modulation transfer function (MTF) and noise-power spectrum (NPS). The algorithms were evaluated over a CTDIvol range of 0.75-18.7 mGy on four major MDCT scanners: GE DiscoveryCT750HD (algorithms: ASIR™ and VEO™); Siemens Somatom Definition AS+ (algorithm: SAFIRE™); Toshiba Aquilion64 (algorithm: AIDR3D™); and Philips Ingenuity iCT256 (algorithm: iDose4™). Images were reconstructed using FBP and the respective iterative algorithms on the four scanners. Use of iterative algorithms decreased image noise and increased CNR, relative to FBP. In the dose range of 1.3-1.5 mGy, noise reduction using iterative algorithms was in the range of 11%-51% on GE DiscoveryCT750HD, 10%-52% on Siemens Somatom Definition AS+, 49%-62% on Toshiba Aquilion64, and 13%-44% on Philips Ingenuity iCT256. The corresponding CNR increase was in the range 11%-105% on GE, 11%-106% on Siemens, 85%-145% on Toshiba and 13%-77% on Philips respectively. Most algorithms did not affect the MTF, except for VEO™ which produced an increase in the limiting resolution of up to 30%. A shift in the peak of the NPS curve towards lower frequencies and a decrease in NPS amplitude were obtained with all iterative algorithms. VEO™ required long reconstruction times, while all other algorithms produced reconstructions in real time. Compared to FBP, iterative algorithms reduced image noise and increased CNR. The iterative algorithms available on different scanners achieved different levels of noise reduction and CNR increase while spatial resolution improvements were obtained only with VEO™. This study is useful in that it provides performance assessment of the iterative algorithms available from several mainstream CT manufacturers.

  13. SU-F-R-39: Effects of Radiation Dose Reduction On Renal Cell Carcinoma Discrimination Using Multi-Phasic CT Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wahi-Anwar, M; Young, S; Lo, P

    Purpose: A method to discriminate different types of renal cell carcinoma (RCC) was developed using attenuation values observed in multiphasic contrast-enhanced CT. This work evaluates the sensitivity of this RCC discrimination task at different CT radiation dose levels. Methods: We selected 5 cases of kidney lesion patients who had undergone four-phase CT scans covering the abdomen to the lilac crest. Through an IRB-approved study, the scans were conducted on 64-slice CT scanners (Definition AS/Definition Flash, Siemens Healthcare) using automatic tube-current modulation (TCM). The protocol included an initial baseline unenhanced scan, followed by three post-contrast injection phases. CTDIvol (32 cm phantom)more » measured between 9 to 35 mGy for any given phase. As a preliminary study, we limited the scope to the cortico-medullary phase—shown previously to be the most discriminative phase. A previously validated method was used to simulate a reduced dose acquisition via adding noise to raw CT sinogram data, emulating corresponding images at simulated doses of 50%, 25%, and 10%. To discriminate the lesion subtype, ROIs were placed in the most enhancing region of the lesion. The mean HU value of an ROI was extracted and used to discriminate to the worst-case RCC subtype, ranked in the order of clear cell, papillary, chromophobe and the benign oncocytoma. Results: Two patients exhibited a change of worst case RCC subtype between original and simulated scans, at 25% and 10% doses. In one case, the worst-case RCC subtype changed from oncocytoma to chromophobe at 10% and 25% doses, while the other case changed from oncocytoma to clear cell at 10% dose. Conclusion: Based on preliminary results from an initial cohort of 5 patients, worst-case RCC subtypes remained constant at all simulated dose levels except for 2 patients. Further study conducted on more patients will be needed to confirm our findings. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH Grant Support from: U01 CA181156.« less

  14. TH-AB-207A-05: A Fully-Automated Pipeline for Generating CT Images Across a Range of Doses and Reconstruction Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, S; Lo, P; Hoffman, J

    Purpose: To evaluate the robustness of CAD or Quantitative Imaging methods, they should be tested on a variety of cases and under a variety of image acquisition and reconstruction conditions that represent the heterogeneity encountered in clinical practice. The purpose of this work was to develop a fully-automated pipeline for generating CT images that represent a wide range of dose and reconstruction conditions. Methods: The pipeline consists of three main modules: reduced-dose simulation, image reconstruction, and quantitative analysis. The first two modules of the pipeline can be operated in a completely automated fashion, using configuration files and running the modulesmore » in a batch queue. The input to the pipeline is raw projection CT data; this data is used to simulate different levels of dose reduction using a previously-published algorithm. Filtered-backprojection reconstructions are then performed using FreeCT-wFBP, a freely-available reconstruction software for helical CT. We also added support for an in-house, model-based iterative reconstruction algorithm using iterative coordinate-descent optimization, which may be run in tandem with the more conventional recon methods. The reduced-dose simulations and image reconstructions are controlled automatically by a single script, and they can be run in parallel on our research cluster. The pipeline was tested on phantom and lung screening datasets from a clinical scanner (Definition AS, Siemens Healthcare). Results: The images generated from our test datasets appeared to represent a realistic range of acquisition and reconstruction conditions that we would expect to find clinically. The time to generate images was approximately 30 minutes per dose/reconstruction combination on a hybrid CPU/GPU architecture. Conclusion: The automated research pipeline promises to be a useful tool for either training or evaluating performance of quantitative imaging software such as classifiers and CAD algorithms across the range of acquisition and reconstruction parameters present in the clinical environment. Funding support: NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.« less

  15. Optimal whole-body PET scanner configurations for different volumes of LSO scintillator: a simulation study.

    PubMed

    Poon, Jonathan K; Dahlbom, Magnus L; Moses, William W; Balakrishnan, Karthik; Wang, Wenli; Cherry, Simon R; Badawi, Ramsey D

    2012-07-07

    The axial field of view (AFOV) of the current generation of clinical whole-body PET scanners range from 15-22 cm, which limits sensitivity and renders applications such as whole-body dynamic imaging or imaging of very low activities in whole-body cellular tracking studies, almost impossible. Generally, extending the AFOV significantly increases the sensitivity and count-rate performance. However, extending the AFOV while maintaining detector thickness has significant cost implications. In addition, random coincidences, detector dead time, and object attenuation may reduce scanner performance as the AFOV increases. In this paper, we use Monte Carlo simulations to find the optimal scanner geometry (i.e. AFOV, detector thickness and acceptance angle) based on count-rate performance for a range of scintillator volumes ranging from 10 to 93 l with detector thickness varying from 5 to 20 mm. We compare the results to the performance of a scanner based on the current Siemens Biograph mCT geometry and electronics. Our simulation models were developed based on individual components of the Siemens Biograph mCT and were validated against experimental data using the NEMA NU-2 2007 count-rate protocol. In the study, noise-equivalent count rate (NECR) was computed as a function of maximum ring difference (i.e. acceptance angle) and activity concentration using a 27 cm diameter, 200 cm uniformly filled cylindrical phantom for each scanner configuration. To reduce the effect of random coincidences, we implemented a variable coincidence time window based on the length of the lines of response, which increased NECR performance up to 10% compared to using a static coincidence time window for scanners with a large maximum ring difference values. For a given scintillator volume, the optimal configuration results in modest count-rate performance gains of up to 16% compared to the shortest AFOV scanner with the thickest detectors. However, the longest AFOV of approximately 2 m with 20 mm thick detectors resulted in performance gains of 25-31 times higher NECR relative to the current Siemens Biograph mCT scanner configuration.

  16. Optimal whole-body PET scanner configurations for different volumes of LSO scintillator: a simulation study

    PubMed Central

    Poon, Jonathan K; Dahlbom, Magnus L; Moses, William W; Balakrishnan, Karthik; Wang, Wenli; Cherry, Simon R; Badawi, Ramsey D

    2013-01-01

    The axial field of view (AFOV) of the current generation of clinical whole-body PET scanners range from 15–22 cm, which limits sensitivity and renders applications such as whole-body dynamic imaging, or imaging of very low activities in whole-body cellular tracking studies, almost impossible. Generally, extending the AFOV significantly increases the sensitivity and count-rate performance. However, extending the AFOV while maintaining detector thickness has significant cost implications. In addition, random coincidences, detector dead time, and object attenuation may reduce scanner performance as the AFOV increases. In this paper, we use Monte Carlo simulations to find the optimal scanner geometry (i.e. AFOV, detector thickness and acceptance angle) based on count-rate performance for a range of scintillator volumes ranging from 10 to 90 l with detector thickness varying from 5 to 20 mm. We compare the results to the performance of a scanner based on the current Siemens Biograph mCT geometry and electronics. Our simulation models were developed based on individual components of the Siemens Biograph mCT and were validated against experimental data using the NEMA NU-2 2007 count-rate protocol. In the study, noise-equivalent count rate (NECR) was computed as a function of maximum ring difference (i.e. acceptance angle) and activity concentration using a 27 cm diameter, 200 cm uniformly filled cylindrical phantom for each scanner configuration. To reduce the effect of random coincidences, we implemented a variable coincidence time window based on the length of the lines of response, which increased NECR performance up to 10% compared to using a static coincidence time window for scanners with large maximum ring difference values. For a given scintillator volume, the optimal configuration results in modest count-rate performance gains of up to 16% compared to the shortest AFOV scanner with the thickest detectors. However, the longest AFOV of approximately 2 m with 20 mm thick detectors resulted in performance gains of 25–31 times higher NECR relative to the current Siemens Biograph mCT scanner configuration. PMID:22678106

  17. Optimal whole-body PET scanner configurations for different volumes of LSO scintillator: a simulation study

    NASA Astrophysics Data System (ADS)

    Poon, Jonathan K.; Dahlbom, Magnus L.; Moses, William W.; Balakrishnan, Karthik; Wang, Wenli; Cherry, Simon R.; Badawi, Ramsey D.

    2012-07-01

    The axial field of view (AFOV) of the current generation of clinical whole-body PET scanners range from 15-22 cm, which limits sensitivity and renders applications such as whole-body dynamic imaging or imaging of very low activities in whole-body cellular tracking studies, almost impossible. Generally, extending the AFOV significantly increases the sensitivity and count-rate performance. However, extending the AFOV while maintaining detector thickness has significant cost implications. In addition, random coincidences, detector dead time, and object attenuation may reduce scanner performance as the AFOV increases. In this paper, we use Monte Carlo simulations to find the optimal scanner geometry (i.e. AFOV, detector thickness and acceptance angle) based on count-rate performance for a range of scintillator volumes ranging from 10 to 93 l with detector thickness varying from 5 to 20 mm. We compare the results to the performance of a scanner based on the current Siemens Biograph mCT geometry and electronics. Our simulation models were developed based on individual components of the Siemens Biograph mCT and were validated against experimental data using the NEMA NU-2 2007 count-rate protocol. In the study, noise-equivalent count rate (NECR) was computed as a function of maximum ring difference (i.e. acceptance angle) and activity concentration using a 27 cm diameter, 200 cm uniformly filled cylindrical phantom for each scanner configuration. To reduce the effect of random coincidences, we implemented a variable coincidence time window based on the length of the lines of response, which increased NECR performance up to 10% compared to using a static coincidence time window for scanners with a large maximum ring difference values. For a given scintillator volume, the optimal configuration results in modest count-rate performance gains of up to 16% compared to the shortest AFOV scanner with the thickest detectors. However, the longest AFOV of approximately 2 m with 20 mm thick detectors resulted in performance gains of 25-31 times higher NECR relative to the current Siemens Biograph mCT scanner configuration.

  18. SU-F-P-45: Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weir, V; Zhang, J

    2016-06-15

    Purpose: Iterative reconstruction (IR) algorithms have been adopted by medical centers in the past several years. IR has a potential to substantially reduce patient dose while maintaining or improving image quality. This study characterizes dose reductions in clinical settings for CT examinations using IR. Methods: We retrospectively analyzed dose information from patients who underwent abdomen/pelvis CT examinations with and without contrast media in multiple locations of our Healthcare system. A total of 743 patients scanned with ASIR on 64 slice GE lightspeed VCTs at three sites, and 30 patients scanned with SAFIRE on a Siemens 128 slice Definition Flash inmore » one site was retrieved. For comparison, patient data (n=291) from a GE scanner and patient data (n=61) from two Siemens scanners where filtered back-projection (FBP) was used was collected retrospectively. 30% and 10% ASIR, and SAFIRE Level 2 was used. CTDIvol, Dose-length-product (DLP), weight and height from all patients was recorded. Body mass index (BMI) was calculated accordingly. To convert CTDIvol to SSDE, AP and lateral dimensions at the mid-liver level was measured for each patient. Results: Compared with FBP, 30% ASIR reduces dose by 44.1% (SSDE: 12.19mGy vs. 21.83mGy), while 10% ASIR reduced dose by 20.6% (SSDE 17.32mGy vs. 21.83). Use of SAFIRE reduced dose by 61.4% (SSDE: 8.77mGy vs. 22.7mGy). The geometric mean for patients scanned with ASIR was larger than for patients scanned with FBP (geometric mean is 297.48 mmm vs. 284.76 mm). The same trend was observed for the Siemens scanner where SAFIRE was used (geometric mean: 316 mm with SAFIRE vs. 239 mm with FBP). Patient size differences suggest that further dose reduction is possible. Conclusion: Our data confirmed that in clinical practice IR can significantly reduce dose to patients who undergo CT examinations, while meeting diagnostic requirements for image quality.« less

  19. WE-FG-207B-10: Dual-Energy CT Monochromatic Image Consistency Across Vendors and Platforms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobsen, M; Wood, C; Cody, D

    Purpose: Although dual-energy CT provides improved sensitivity of HU for certain tissue types at lower simulated energy levels, if these values vary by scanner type they may impact clinical patient management decisions. Each manufacturer has selected a specific dual-energy CT approach (or in one case, three different approaches); understanding HU variability among low monochromatic images may be required when more than one dual-energy CT scanner type is available for use. Methods: A large elliptical dualenergy quality control phantom (Gammex Inc.; Middleton, WI) containing several standard tissue type materials was scanned at least three times on each of the following systems:more » GE HD750, prototype GE Revolution CT with GSI, Siemens Flash, Siemens Edge, Siemens AS 128, and Philips IQon. Images were generated at 50, 70, and 140 keV. Soft tissue and Iodine HU were measured on a single central 5mm-thick image; NIST constants were used to calculate the ideal HU for each material. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were held as consistent as possible (thickness, kernel, no noise reduction). Results: Measured soft tissue (29 HU at 120 kVp) varied from 28 HU to 44 HU at 50 keV (excluding one outlier), from 21 HU to 31 HU at 70 keV, and from 19 HU to 32 HU at 140 keV. Measured iodine (5mg/ml, 106 HU at 120 kVp) varied from 246 HU to 280 HU at 50 keV, from 123 HU to 129 HU at 70 keV, and from 22 HU to 32 HU at 140 keV. Conclusion: Measured HU in standard rods across 3 dual-energy CT manufacturers and 6 scanner models varied directly with monochromatic level, with the most variability was observed at 50 keV and least variability at 70keV. Future work will include additional scanner platforms and how measurement variability impacts radiologists. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.« less

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blackwell, David D.; Chickering Pace, Cathy; Richards, Maria C.

    The National Geothermal Data System (NGDS) is a Department of Energy funded effort to create a single cataloged source for a variety of geothermal information through a distributed network of databases made available via web services. The NGDS will help identify regions suitable for potential development and further scientific data collection and analysis of geothermal resources as a source for clean, renewable energy. A key NGDS repository or ‘node’ is located at Southern Methodist University developed by a consortium made up of: • SMU Geothermal Laboratory • Siemens Corporate Technology, a division of Siemens Corporation • Bureau of Economic Geologymore » at the University of Texas at Austin • Cornell Energy Institute, Cornell University • Geothermal Resources Council • MLKay Technologies • Texas Tech University • University of North Dakota. The focus of resources and research encompass the United States with particular emphasis on the Gulf Coast (on and off shore), the Great Plains, and the Eastern U.S. The data collection includes the thermal, geological and geophysical characteristics of these area resources. Types of data include, but are not limited to, temperature, heat flow, thermal conductivity, radiogenic heat production, porosity, permeability, geological structure, core geophysical logs, well tests, estimated reservoir volume, in situ stress, oil and gas well fluid chemistry, oil and gas well information, and conventional and enhanced geothermal system related resources. Libraries of publications and reports are combined into a unified, accessible, catalog with links for downloading non-copyrighted items. Field notes, individual temperature logs, site maps and related resources are included to increase data collection knowledge. Additional research based on legacy data to improve quality increases our understanding of the local and regional geology and geothermal characteristics. The software to enable the integration, analysis, and dissemination of this team’s NGDS contributions was developed by Siemens Corporate Technology. The SMU Node interactive application is accessible at http://geothermal.smu.edu. Additionally, files may be downloaded from either http://geothermal.smu.edu:9000/geoserver/web/ or through http://geothermal.smu.edu/static/DownloadFilesButtonPage.htm. The Geothermal Resources Council Library is available at https://www.geothermal-library.org/.« less

  1. A phantom study for the comparison of different brands of computed tomography scanners and software packages for endovascular aneurysm repair sizing and planning.

    PubMed

    Velu, Juliëtte F; Groot Jebbink, Erik; de Vries, Jean-Paul Pm; van der Palen, Job Am; Slump, Cornelis H; Geelkerken, Robert H

    2018-04-01

    Objectives Correct sizing of endoprostheses used for the treatment of abdominal aortic aneurysms is important to prevent endoleaks and migration. Sizing requires several steps and each step introduces a possible sizing error. The goal of this study was to investigate the magnitude of these errors compared to the golden standard: a vessel phantom. This study focuses on the errors in sizing with three different brands of computed tomography angiography scanners in combination with three reconstruction software packages. Methods Three phantoms with a different diameter, altitude and azimuth were scanned with three computed tomography scanners: Toshiba Aquilion 64-slice, Philips Brilliance iCT 256-slice and Siemens Somatom Sensation 64-slice. The phantom diameters were determined in the stretched view after central lumen line reconstruction by three observers using Simbionix PROcedure Rehearsal Studio, 3mensio and TeraRecon planning software. The observers, all novices in sizing endoprostheses using planning software, measured 108 slices each. Two senior vascular surgeons set the tolerated error margin of sizing on ±1.0 mm. Results In total, 11.3% of the measurements (73/648) were outside the set margins of ±1.0 mm from the phantom diameter, with significant differences between the scanner types (14.8%, 12.1%, 6.9% for the Siemens scanner, Philips scanner and Toshiba scanner, respectively, p-value = 0.032), but not between the software packages (8.3%, 11.1%, 14.4%, p-value = 0.141) or the observers (10.6%, 9.7%, 13.4%, p-value = 0.448). Conclusions It can be concluded that the errors in sizing were independent of the used software packages, but the phantoms scanned with Siemens scanner were significantly more measured incorrectly than the phantoms scanned with the Toshiba scanner. Consequently, awareness on the type of computed tomography scanner and computed tomography scanner setting is necessary, especially in complex abdominal aortic aneurysms sizing for fenestrated or branched endovascular aneurysm repair if appropriate the sizing is of upmost importance.

  2. Estimation of the weighted CTDI{sub {infinity}} for multislice CT examinations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li Xinhua; Zhang Da; Liu, Bob

    2012-02-15

    Purpose: The aim of this study was to examine the variations of CT dose index (CTDI) efficiencies, {epsilon}(CTDI{sub 100})=CTDI{sub 100}/CTDI{sub {infinity}}, with bowtie filters and CT scanner types. Methods: This was an extension of our previous study [Li, Zhang, and Liu, Phys. Med. Biol. 56, 5789-5803 (2011)]. A validated Monte Carlo program was used to calculate {epsilon}(CTDI{sub 100}) on a Siemens Somatom Definition scanner. The {epsilon}(CTDI{sub 100}) dependencies on tube voltages and beam widths were tested in previous studies. The influences of different bowtie filters and CT scanner types were examined in this work. The authors tested the variations ofmore » {epsilon}(CTDI{sub 100}) with bowtie filters on the Siemens Definition scanner. The authors also analyzed the published CTDI measurements of four independent studies on five scanners of four models from three manufacturers. Results: On the Siemens Definition scanner, the difference in {epsilon}(CTDI{sub W}) between using the head and body bowtie filters was 2.5% (maximum) in the CT scans of the 32-cm phantom, and 1.7% (maximum) in the CT scans of the 16-cm phantom. Compared with CTDI{sub W}, the weighted CTDI{sub {infinity}} increased by 30.5% (on average) in the 32-cm phantom, and by 20.0% (on average) in the 16-cm phantom. These results were approximately the same for 80-140 kV and 1-40 mm beam widths (4.2% maximum deviation). The differences in {epsilon}(CTDI{sub 100}) between the simulations and the direct measurements of four previous studies were 1.3%-5.0% at the center/periphery of the 16-cm/32-cm phantom (on average). Conclusions: Compared with CTDI{sub vol}, the equilibrium dose for large scan lengths is 30.5% higher in the 32-cm phantom, and is 20.0% higher in the 16-cm phantom. The relative increases are practically independent of tube voltages (80-140 kV), beam widths (up to 4 cm), and the CT scanners covered in this study.« less

  3. Reform of health care in Germany

    PubMed Central

    Hurst, Jeremy W.

    1991-01-01

    For the past 45 years Germany has had two health care systems: one in the former Federal Republic of Germany and one in the former German Democratic Republic. The system in the Federal Republic was undergoing some important reforms when German reunification took place in October 1990. Now the system in eastern Germany is undergoing a major transformation to bring it more into line with that in western Germany. PMID:10110879

  4. 48 CFR 252.229-7002 - Customs exemptions (Germany).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (Germany). 252.229-7002 Section 252.229-7002 Federal Acquisition Regulations System DEFENSE ACQUISITION... of Provisions And Clauses 252.229-7002 Customs exemptions (Germany). As prescribed in 229.402-70(b), use the following clause: Customs Exemptions (Germany) (JUN 1997) Imported products required for the...

  5. 48 CFR 252.229-7002 - Customs exemptions (Germany).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (Germany). 252.229-7002 Section 252.229-7002 Federal Acquisition Regulations System DEFENSE ACQUISITION... of Provisions And Clauses 252.229-7002 Customs exemptions (Germany). As prescribed in 229.402-70(b), use the following clause: Customs Exemptions (Germany) (JUN 1997) Imported products required for the...

  6. 48 CFR 252.229-7002 - Customs exemptions (Germany).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (Germany). 252.229-7002 Section 252.229-7002 Federal Acquisition Regulations System DEFENSE ACQUISITION... of Provisions And Clauses 252.229-7002 Customs exemptions (Germany). As prescribed in 229.402-70(b), use the following clause: Customs Exemptions (Germany) (JUN 1997) Imported products required for the...

  7. 48 CFR 252.229-7002 - Customs exemptions (Germany).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... (Germany). 252.229-7002 Section 252.229-7002 Federal Acquisition Regulations System DEFENSE ACQUISITION... of Provisions And Clauses 252.229-7002 Customs exemptions (Germany). As prescribed in 229.402-70(b), use the following clause: Customs Exemptions (Germany) (JUN 1997) Imported products required for the...

  8. 48 CFR 252.229-7002 - Customs exemptions (Germany).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (Germany). 252.229-7002 Section 252.229-7002 Federal Acquisition Regulations System DEFENSE ACQUISITION... of Provisions And Clauses 252.229-7002 Customs exemptions (Germany). As prescribed in 229.402-70(b), use the following clause: Customs Exemptions (Germany) (JUN 1997) Imported products required for the...

  9. SU-G-IeP1-08: MR Geometric Distortion Dependency On Imaging Sequence, Acquisition Orientation and Receiver Bandwidth of a Dedicated 1.5T MR-Simulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Law, M; Yuan, J; Wong, O

    Purpose: To investigate the 3D geometric distortion of four potential MR sequences for radiotheraptic applications, and its dependency on sequence-type, acquisition-orientation and receiver-bandwidth from a dedicated 1.5T 700mm-wide bore MR-simulator (Magnetom-Aera, Sienmens Healthcare, Erlangen, Germany), using a large customized geometric accuracy phantom. Methods: This work studied 3D gradient-echo (VIBE) and spin-echo (SPACE) sequences for anatomical imaging; a specific ultra-short-TE sequence (PETRA) potentially for bone imaging and MR-based dosimetry; and a motion-insensitive sequence (BLADE) for dynamic applications like 4D-MRI. Integrated geometric-correction was employed, three orthogonal acquisition-orientations and up to three receiver-bandwidths were used, yielding 27 acquisitions for testing (Table 1a).A customizedmore » geometric accuracy phantom (polyurethane, MR/CT invisible, W×L×H:55×55×32.5cm3) was constructed and filled with 3892 spherical markers (6mm diameter, MR/CT visible) arranged on a 25mm-interval 3D isotropic-grid (Fig.1). The marker positions in MR images were quantitatively calculated and compared against those in the CT-reference using customized MatLab scripts. Results: The average distortion within various diameter-of-spherical-volumes (DSVs) and the usable DSVs under various distortion limits were measured (Tables 1b-c). It was observed that distortions fluctuated when sequence-type, acquisition-orientation or receiver-bandwidth changed (e.g. within 300mm-DSV, the lowest/highest average distortions of VIBE were 0.40mm/0.59mm, a 47.5% difference). According to AAPM-TG66 (<1mm distortion, left-most column of Table 1c), PETRA (Largest-DSV:253.9mm) has the potential on brain treatment, while BLADE (Largest-DSV:207.2mm) may need improvement for thoracic/abdominal applications. The results of VIBE (Largest-DSVs:294.3mm, the best among tested acquisitions) and SPACE (Largest-DSVs:267.7mm) suggests their potentials on head and neck applications. These Largest-DSVs were attained on different acquisition-orientations and receiver-bandwidths. Conclusion: Geometric distortion was shown to be dependent on sequence-type, acquisition-orientation and receiver-bandwidth. In the experiment, no configuration in any one of these factors could consistently reduce distortion while the others were varying. The distortion analysis result is a valuable guideline for sequence selection and optimization for MR-aided radiotherapy applications.« less

  10. Health hazards from fine asbestos dusts. An analysis of 70,656 occupational preventive medical investigations from 1973 to the end of 1986.

    PubMed

    Raithel, H J; Weltle, D; Bohlig, H; Valentin, H

    1989-01-01

    For the period from 1973 to the end of 1986, 70,656 data sets on occupational preventive medical examinations in employees exposed occupationally to asbestos dust (G 1.2) were made available to us by the Central Registry for Employees Exposed to Asbestos Dust (ZAS). On the basis of this data, an analysis of asbestosis risk was to be made in relation to specific areas of work, taking into consideration the beginning and duration of exposure. Proceedings for declaratory appraisal in accordance with occupational disease no. 4103 were instituted in 1760 cases in the report period. In accordance with the character of the available data, the X-ray findings in the lungs were available from the persons investigated as parameters of possible asbestosis risk on the basis of coding consistent with the International Pneumoconiosis Classification (ILO U/C 1971 and/or ILO 1980 West Germany). The major result of the statistical analyses on the mainframe macrocomputer of the University of Erlangen-Nuremberg was that the relatively highest risk of asbestosis was present in persons whose exposure began before 1955. On the other hand, with increasing duration of exposure, an unequivocal rise of the asbestosis risk could not be detected on the basis of the overall population. In relation to the individual fields of work, the relatively highest risk of asbestosis was shown to be in the asbestos textile and paper industry, as well as in the asbestos cement industry. No detectable risk of asbestosis was present in the fields of mining, traffic and health service and for women in the industrial sectors of building material, gas and water, catering trade, building, commerce as well as banking and insurance. Accordingly, it can be assumed that certain fields of work are or were exposed to such a small extent or not at all that a risk of asbestosis which is relevant in terms of occupational medicine is no longer to be assumed or was not to be assumed. This applies above all to certain work in the frictional coating (brake lining) and asbestos paper industry. Furthermore, the analysis of the data material did not provide any unequivocal indications that inhalative smoking habits have a negative effect on the risk of asbestosis. In principle, it can be stated that the occupational preventive medical investigations according to G 1.2 are effective.(ABSTRACT TRUNCATED AT 400 WORDS)

  11. [Scanning electron microscopic investigations of cutting edge quality in lamellar keratotomy using the Wavelight femtosecond laser (FS-200) : What influence do spot distance and an additional tunnel have?

    PubMed

    Hammer, T; Höche, T; Heichel, J

    2018-01-01

    Femtosecond lasers (fs-lasers) are established cutting instruments for the creation of LASIK flaps. Previous studies often showed even rougher surfaces after application of fs-laser systems compared to lamellar keratotomy with mechanical microkeratomes. When cutting the cornea with fs-lasers, an intrastromal gas development occurs, which has a potentially negative influence on the cutting quality if the gas cannot be dissipated; therefore, manufacturers have chosen the way of gas assimilation in so-called pockets. The investigated system creates a tunnel which opens under the conjunctiva. The aim of this study was to investigate the effects of a tunnel as well as the influence of different spot distances on the quality of cut surfaces and edges. In this experimental study on freshly enucleated porcine eyes (n = 15), the following cuts were carried out with the FS-200 (Wavelight, Erlangen, Germany): 1. standard setting (spot and line separation 8 µm), 2. with tunnel for gas drainage, 3. without gas-conducting tunnel, 4. with increased spot spacing (spot and line separation 9 μm instead of 8 μm) and 5. with reduced spot spacing (spot and line separation 7 μm instead of 8 μm). Subsequently, scanning electron microscopy (FEI Quanta 650, Hillsboro, OR) of the cut edges and surfaces as well as the gas drain tunnel were performed. The evaluation was based on an established score. The current fs-laser system (200 Hz) is able to create smooth cutting surfaces and sharp edges. The changed density of laser pulses compared to the standard settings with a reduced or increased distance between the pulses, did not achieve any further improvement in the surface quality. The gas-conducting tunnel could be detected by scanning electron microscope. In the case of cutting without a tunnel, roughened surfaces and irregularities on the cutting edges were found. When the FS-200 fs-laser is used, LASIK cuts with very smooth cut surfaces and sharp cutting edges are achieved. This is only valid as long as an additional tunnel with the fs-laser is placed under the conjunctiva. It can be assumed that the resulting gas is effectively drained through this tunnel. The installation of the tunnel represents a new possibility to replace previous techniques of gas assimilation in deeper lying cutting areas.

  12. Exercise effects on bone mineral density, falls, coronary risk factors, and health care costs in older women: the randomized controlled senior fitness and prevention (SEFIP) study.

    PubMed

    Kemmler, Wolfgang; von Stengel, Simon; Engelke, Klaus; Häberle, Lothar; Kalender, Willi A

    2010-01-25

    Physical exercise affects many risk factors and diseases and therefore can play a vital role in general disease prevention and treatment of elderly individuals and may reduce costs. We sought to determine whether a single exercise program affects fracture risk (bone mineral density [BMD] and falls), coronary heart disease (CHD) risk factors, and health care costs in community-dwelling elderly women. We conducted a randomized, single-blinded, controlled trial from May 1, 2005, through July 31, 2008, recruiting women 65 years or older who were living independently in the area of Erlangen-Nuremberg, Germany. In all, 246 women were randomly assigned to an 18-month exercise program (exercise group) or a wellness program (control group). The exercise group (n = 123) performed a multipurpose exercise program with special emphasis on exercise intensity; the controls (n = 123) focused on well-being with a low-intensity, low-frequency program. The main outcome measures were BMD, the number of falls, the Framingham-based 10-year CHD risk, and direct health care costs. For the 227 women who completed the 18-month study, significant exercise effects were observed for BMD of the lumbar spine (mean [95% confidence interval (CI)] percentage of change in BMD [baseline to follow-up] for the exercise group: 1.77% [1.26% to 2.28%] vs controls: 0.33% [-0.24% to 0.91%]; P < .001), femoral neck (exercise group: 1.01% [0.37% to 1.65%] vs controls: -1.05% [-1.70% to -0.40%]; P < .001), and fall rate per person during 18 months (exercise group: 1.00 [0.76 to 1.24] vs controls: 1.66 [1.33 to 1.99]; P = .002). The 10-year CHD risk was significantly affected in both subgroups (absolute change for the exercise group: -1.96% [95% CI, -2.69% to -1.23%] vs controls: -1.15% [-1.69% to -0.62%]; P = .22), with no significant difference between the groups. The direct health care costs per participant during the 18-month intervention showed nonsignificant differences between the groups (exercise group: 2255 euros[95% CI, 1791 euros-2718 euros] vs controls: 2780 euros [2187 euros-3372 euros]; P = .20). Compared with a general wellness program, our 18-month exercise program significantly improved BMD and fall risk, but not predicted CHD risk, in elderly women. This benefit occurred at no increase in direct costs. clinicaltrials.gov Identifier: NCT00267839.

  13. 48 CFR 252.246-7002 - Warranty of construction (Germany).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (Germany). 252.246-7002 Section 252.246-7002 Federal Acquisition Regulations System DEFENSE ACQUISITION... of Provisions And Clauses 252.246-7002 Warranty of construction (Germany). As prescribed in 246.710(4), use the following clause: Warranty of Construction (Germany) (JUN 1997) (a) In addition to any other...

  14. 48 CFR 252.246-7002 - Warranty of construction (Germany).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (Germany). 252.246-7002 Section 252.246-7002 Federal Acquisition Regulations System DEFENSE ACQUISITION... of Provisions And Clauses 252.246-7002 Warranty of construction (Germany). As prescribed in 246.710(4), use the following clause: Warranty of Construction (Germany) (JUN 1997) (a) In addition to any other...

  15. 48 CFR 252.246-7002 - Warranty of construction (Germany).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (Germany). 252.246-7002 Section 252.246-7002 Federal Acquisition Regulations System DEFENSE ACQUISITION... of Provisions And Clauses 252.246-7002 Warranty of construction (Germany). As prescribed in 246.710(4), use the following clause: Warranty of Construction (Germany) (JUN 1997) (a) In addition to any other...

  16. 48 CFR 252.246-7002 - Warranty of construction (Germany).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (Germany). 252.246-7002 Section 252.246-7002 Federal Acquisition Regulations System DEFENSE ACQUISITION... of Provisions And Clauses 252.246-7002 Warranty of construction (Germany). As prescribed in 246.710(2), use the following clause: Warranty of Construction (Germany) (JUN 1997) (a) In addition to any other...

  17. 48 CFR 252.246-7002 - Warranty of construction (Germany).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... (Germany). 252.246-7002 Section 252.246-7002 Federal Acquisition Regulations System DEFENSE ACQUISITION... of Provisions And Clauses 252.246-7002 Warranty of construction (Germany). As prescribed in 246.710(4), use the following clause: Warranty of Construction (Germany) (JUN 1997) (a) In addition to any other...

  18. 75 FR 3444 - Ball Bearings and Parts Thereof From Germany: Initiation of Antidumping Duty Changed...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-21

    ... Thereof From Germany: Initiation of Antidumping Duty Changed-Circumstances Review AGENCY: Import... bearings and parts thereof from Germany with respect to myonic GmbH. DATES: Effective Date: January 21... Germany on May 15, 1989. See Antidumping Duty Orders: Ball Bearings, Cylindrical Roller Bearings, and...

  19. Education in Germany: A Bibliography of English Language Publications.

    ERIC Educational Resources Information Center

    Max-Planck-Institut fuer Bildungsforschung, Berlin (West Germany).

    This bibliography cites bibliographies, journals, books, essays, journal articles, and monographs on education in Germany. All publications cited are in English. The three major sections of the bibliography are education in Germany up to 1945, education in the Federal Republic of Germany, and education in the German Democratic Republic. Topics…

  20. 78 FR 70574 - Grain-Oriented Electrical Steel From China, Czech Republic, Germany, Japan, Korea, Poland, and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-26

    ...)] Grain-Oriented Electrical Steel From China, Czech Republic, Germany, Japan, Korea, Poland, and Russia..., Germany, Japan, Korea, Poland, and Russia of grain-oriented electrical steel, provided for in subheadings... Republic, Germany, Japan, Korea, Poland, and Russia. Accordingly, effective September 18, 2013, the...

  1. The Definition of Vocational Diplomas in Germany and France.

    ERIC Educational Resources Information Center

    Mobus, Martine; Verdier, Eric

    1997-01-01

    In both France and Germany, the government, employers' organizations, and unions all participate in defining vocational diplomas based on a national framework of procedures of elaborating and standardizing titles. Important differences between the diploma definition processes in France and Germany may be identified. In Germany, the issue is…

  2. 75 FR 37759 - Initiation of Antidumping and Countervailing Duty Administrative Reviews and Requests for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-30

    ...... 5/1/09-4/30/10 Alcatel Vacuum Technology Audi AG AVIAC Avio (formerly known as FiatAvio) Bosch... Audi AG Avio (formerly known as FiatAvio) BAUER Maschinen GmbH Bosch Rexroth AG BSH Bosch und Siemens... Bearings and Parts Thereof, A-475-201.... 5/1/09-4/30/10 Audi AG Avio, S.p.A. (formerly known as FiatAvio...

  3. Results of SEI Independent Research and Development Projects

    DTIC Science & Technology

    2007-07-01

    have established the following success criteria for our project : • developing a formal framework for systematically measuring a system’s attack...characteristics may change, depending on the current stage of the project development . During the initial stages of a project , one might see, for example...was based on the Siemens Global Studio project , which exists to provide a test bed for studying global development practices. The qualitative path

  4. A Survey of Commonly Applied Methods for Software Process Improvement

    DTIC Science & Technology

    1994-02-01

    conducted a controlled experimental study of the effectiveness of the method. They compared 10 cleanroom teams with 5 non -cleanroom teams working for six...Robert D. Austin Doctoral Candidate Carnegie Mellon University Daniel J. Paulish Resident Affiliate Siemens Corporate Research , Inc. Accesion For0...the U.S. Department of Defense. Copyright 0 1994 by Carnegie Mellon University. Copies of the documen are available from Research Access. Iinc., 800

  5. JPRS Report, Science & Technology. Europe: Economic Competitiveness

    DTIC Science & Technology

    1992-03-11

    As a consequence of this expansion, the yearly production capacity of Japanese firms ( Nissan , Toyota , and Honda ) in Great Britain will increase to...Circuits via Siemens [Francoise Grosvalet; Paris ELECTRONIQUE INTERNATIONAL HEBDO, 5 Dec 91] 18 Nissan Expands Auto Production Facilities in...shown in Table 1. It will be clear from a compar - ison of the distribution of funding between the first and second rounds that the proportion of

  6. On-Line Thermal Barrier Coating Monitoring for Real-Time Failure Protection and Life Maximization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis H. LeMieux

    2004-10-01

    Under the sponsorship of the U. S. Department of Energy's National Energy Laboratory, Siemens Westinghouse Power Corporation proposes a four year program titled, ''On-Line Thermal Barrier Coating (TBC) Monitor for Real-Time Failure Protection and Life Maximization'', to develop, build and install the first generation of an on-line TBC monitoring system for use on land -based advanced gas turbines (AGT). Federal deregulation in electric power generation has accelerated power plant owner's demand for improved reliability availability maintainability (RAM) of the land-based advanced gas turbines. As a result, firing temperatures have been increased substantially in the advanced turbine engines, and the TBCsmore » have been developed for maximum protection and life of all critical engine components operating at these higher temperatures. Losing TBC protection can therefore accelerate the degradation of substrate components materials and eventually lead to a premature failure of critical component and costly unscheduled power outages. This program seeks to substantially improve the operating life of high cost gas turbine components using TBC; thereby, lowering the cost of maintenance leading to lower cost of electricity. Siemens Westinghouse Power Corporation has teamed with Indigo Systems; a supplier of state-of-the-art infrared camera systems, and Wayne State University, a leading research organization.« less

  7. Analytical and Clinical Validation of the Immulite 1000 hCG Assay for Quantitative Analysis in Urine

    PubMed Central

    Cate, Frances L.; Moffett, Courtney; Gronowski, Ann M.; Grenache, David G.; Hartmann, Katherine E.; Woodworth, Alison

    2013-01-01

    Background The Siemens Immulite hCG assay detects all major hCG variants in serum. Currently, this assay is only FDA approved for qualitative measurement of hCG in urine. Methods Complete validation of the hCG assay in urine was performed on the Siemens Immulite 1000 immunoassay platform. Reference intervals were established for females <55 y, females ≥55 y, and males 20–70 y. Results The limit of quantitation was 2.0 IU/l. The Immulite hCG assay was precise for measuring hCG in urine from pregnant patients with intra- and inter-assay imprecision of <11% CV. The assay was linear over a dynamic range of 2–2600 IU/l and 2–3500 IU/l for hCG and hCGβ respectively. The assay was non-linear for hCGβcf. No hook effect was observed at concentrations up to 1,200,000 pmol/l, for hCGβ or hCGβcf. The reference intervals were <2.0 IU/l for males, <2.2 IU/l for females <55 y, and <12.2 IU/l for females ≥55 y. Conclusion The Immulite 1000 hCG assay can accurately quantify hCG in urine. PMID:23470427

  8. NOTE: A practical approach for electron monitor unit calculation

    NASA Astrophysics Data System (ADS)

    Choi, David; Patyal, Baldev; Cho, Jongmin; Cheng, Ing Y.; Nookala, Prashanth

    2009-08-01

    Electron monitor unit (MU) calculation requires measured beam data such as the relative output factor (ROF) of a cone, insert correction factor (ICF) and effective source-to-surface distance (ESD). Measuring the beam data to cover all possible clinical cases is not practical for a busy clinic because it takes tremendous time and labor. In this study, we propose a practical approach to reduce the number of data measurements without affecting accuracy. It is based on two findings of dosimetric properties of electron beams. One is that the output ratio of two inserts is independent of the cone used, and the other is that ESD is a function of field size but independent of cone and jaw opening. For the measurements to prove the findings, a parallel plate ion chamber (Markus, PTW 23343) with an electrometer (Cardinal Health 35040) was used. We measured the outputs to determine ROF, ICF and ESD of different energies (5-21 MeV). Measurements were made in a Plastic Water™ phantom or in water. Three linear accelerators were used: Siemens MD2 (S/N 2689), Siemens Primus (S/N 3305) and Varian Clinic 21-EX (S/N 1495). With these findings, the number of data set to be measured can be reduced to less than 20% of the data points.

  9. Validation of a FAST model of the Statoil-Hywind Demo floating wind turbine

    DOE PAGES

    Driscoll, Frederick; Jonkman, Jason; Robertson, Amy; ...

    2016-10-13

    To assess the accuracy of the National Renewable Energy Laboratory's (NREL's) FAST simulation tool for modeling the coupled response of floating offshore wind turbines under realistic open-ocean conditions, NREL developed a FAST model of the Statoil Hywind Demo floating offshore wind turbine, and validated simulation results against field measurements. Field data were provided by Statoil, which conducted a comprehensive test measurement campaign of its demonstration system, a 2.3-MW Siemens turbine mounted on a spar substructure deployed about 10 km off the island of Karmoy in Norway. A top-down approach was used to develop the FAST model, starting with modeling themore » blades and working down to the mooring system. Design data provided by Siemens and Statoil were used to specify the structural, aerodynamic, and dynamic properties. Measured wind speeds and wave spectra were used to develop the wind and wave conditions used in the model. The overall system performance and behavior were validated for eight sets of field measurements that span a wide range of operating conditions. The simulated controller response accurately reproduced the measured blade pitch and power. In conclusion, the structural and blade loads and spectra of platform motion agree well with the measured data.« less

  10. Radio-protective effect of cinnamic acid, a phenolic phytochemical, on genomic instability induced by X-rays in human blood lymphocytes in vitro.

    PubMed

    Cinkilic, Nilufer; Tüzün, Ece; Çetintaş, Sibel Kahraman; Vatan, Özgür; Yılmaz, Dilek; Çavaş, Tolga; Tunç, Sema; Özkan, Lütfi; Bilaloğlu, Rahmi

    2014-08-01

    The present study was designed to determine the protective activity of cinnamic acid against induction by X-rays of genomic instability in normal human blood lymphocytes. This radio-protective activity was assessed by use of the cytokinesis-block micronucleus test and the alkaline comet assay, with human blood lymphocytes isolated from two healthy donors. A Siemens Mevatron MD2 (Siemens AG, USA, 1994) linear accelerator was used for the irradiation with 1 or 2 Gy. Treatment of the lymphocytes with cinnamic acid prior to irradiation reduced the number of micronuclei when compared with that in control samples. Treatment with cinnamic acid without irradiation did not increase the number of micronuclei and did not show a cytostatic effect in the lymphocytes. The results of the alkaline comet assay revealed that cinnamic acid reduces the DNA damage induced by X-rays, showing a significant radio-protective effect. Cinnamic acid decreased the frequency of irradiation-induced micronuclei by 16-55% and reduced DNA breakage by 17-50%, as determined by the alkaline comet assay. Cinnamic acid may thus act as a radio-protective compound, and future studies may focus on elucidating the mechanism by which cinnamic acid offers radioprotection. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Intraoperative CT in the assessment of posterior wall acetabular fracture stability.

    PubMed

    Cunningham, Brian; Jackson, Kelly; Ortega, Gil

    2014-04-01

    Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.

  12. Modeling the Charge Transport in Graphene Nano Ribbon Interfaces for Nano Scale Electronic Devices

    NASA Astrophysics Data System (ADS)

    Kumar, Ravinder; Engles, Derick

    2015-05-01

    In this research work we have modeled, simulated and compared the electronic charge transport for Metal-Semiconductor-Metal interfaces of Graphene Nano Ribbons (GNR) with different geometries using First-Principle calculations and Non-Equilibrium Green's Function (NEGF) method. We modeled junctions of Armchair GNR strip sandwiched between two Zigzag strips with (Z-A-Z) and Zigzag GNR strip sandwiched between two Armchair strips with (A-Z-A) using semi-empirical Extended Huckle Theory (EHT) within the framework of Non-Equilibrium Green Function (NEGF). I-V characteristics of the interfaces were visualized for various transport parameters. The distinct changes in conductance and I-V curves reported as the Width across layers, Channel length (Central part) was varied at different bias voltages from -1V to 1 V with steps of 0.25 V. From the simulated results we observed that the conductance through A-Z-A graphene junction is in the range of 10-13 Siemens whereas the conductance through Z-A-Z graphene junction is in the range of 10-5 Siemens. These suggested conductance controlled mechanisms for the charge transport in the graphene interfaces with different geometries is important for the design of graphene based nano scale electronic devices like Graphene FETs, Sensors.

  13. Designing of a technological line in the context of controlling with the use of integration of the virtual controller with the mechatronics concept designer module of the PLM Siemens NX software

    NASA Astrophysics Data System (ADS)

    Herbuś, K.; Ociepka, P.

    2017-08-01

    In the work is examined the sequential control system of a technological line in the form of the final part of a system of an internal transport. The process of designing this technological line using the computer-aided approach ran concurrently in two different program environments. In the Mechatronics Concept Designer module of the PLM Siemens NX software was developed the 3D model of the technological line prepared for verification the logic interrelations implemented in the control system. For this purpose, from the whole system of the technological line, it was distinguished the sub-system of actuators and sensors, because their correct operation determines the correct operation of the whole system. Whereas in the application of the virtual controller have been implemented the algorithms of work of the planned line. Then both program environments have been integrated using the OPC server, which enables the exchange of data between the considered systems. The data on the state of the object and the data defining the way and sequence of operation of the technological line are exchanged between the virtual controller and the 3D model of the technological line in real time.

  14. Relationships between patient size, dose and image noise under automatic tube current modulation systems.

    PubMed

    Sookpeng, S; Martin, C J; Gentle, D J; Lopez-Gonzalez, M R

    2014-03-01

    Automatic tube current modulation (ATCM) systems are now used for the majority of CT scans. The principles of ATCM operation are different in CT scanners from different manufacturers. Toshiba and GE scanners base the current modulation on a target noise setting, while Philips and Siemens scanners use reference image and reference mAs concepts respectively. Knowledge of the relationships between patient size, dose and image noise are important for CT patient dose optimisation. In this study, the CT patient doses were surveyed for 14 CT scanners from four different CT scanner manufacturers. The patient cross sectional area, the tube current modulation and the image noise from the CT images were analysed using in-house software. The Toshiba and GE scanner results showed that noise levels are relatively constant but tube currents are dependent on patient size. As a result of this there is a wide range in tube current values across different patient sizes, and doses for large patients are significantly higher in these scanners. In contrast, in the Philips and Siemens scanners, tube currents are less dependent on patient size, the range in tube current is narrower, and the doses for larger patients are not as high. Image noise is more dependent on the patient size.

  15. 17 CFR Appendix B to Part 190 - Special Bankruptcy Distributions

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... €50 U.K. C €100 U.K., Germany, or Japan Location Actual asset balance U.S. $50 U.K. €100 Germany €50.... C $20 U.S. C €50 Germany D $100. U.S. D £300 U.K. D €100 U.K., Germany, or Japan E $80 U.S. E ¥10,000 Japan Location Actual asset balance U.S. $200 U.K. £200 U.K. €100 Germany €50 Japan ¥10,000...

  16. [Nanomedicine in otorhinolaryngology--future prospects].

    PubMed

    Dürr, S; Tietze, R; Lyer, S; Alexiou, C

    2012-01-01

    Nanotechnology becomes more and more important in the world of today. Equally, it does generally in medicine and of course specifically in otorhinolaryngology. Essentially, there are the following fields: Diagnostics, new therapies and agents, drug delivery and medical implants. An extensive literature research on nanomedicine in otorhinolaryngology was carried out in the standard online medical reference databases “PubMed/Medline” and “Web of Science”. Furthermore, we are giving an overview of the work of the Department of Otorhinolaryngology, Head and Neck Surgery, Section of Experimental Oncology and Nanomedicine (SEON), University Hospital Erlangen. A lot of new and innovative studies on nanotechnology in diagnostics and therapy were recovered. Depending on the variety in otorhinolaryngology, there are numerous versatile approaches, according to the different areas. The main part is engaged in drug delivery. The efforts to exploit the potential of nanotechnology in otorhinolaryngology are multifaceted, innovative and seminal. The best perspective of success is attributed to nanoparticulate drug delivery systems. © Georg Thieme Verlag KG Stuttgart · New York.

  17. When green and red mycology meet: Impressions from an interdisciplinary forum on virulence mechanisms of phyto- and human-pathogenic fungi.

    PubMed

    Yu, Yidong; Hube, Bernhard; Kämper, Jörg; Meyer, Vera; Krappmann, Sven

    2017-10-03

    Fungal infections pose a constant threat to plants and humans, but detailed knowledge about pathogenesis, immunity, or virulence is rather scarce. Due to the fact that a certain overlap in the armoury of infection exists between plant- and human-pathogenic fungi, an interdisciplinary forum was held in October 2016 at the Institute for Clinical Microbiology, Immunology and Hygiene in Erlangen under the organisational umbrella from two special interest groups of German microbial societies. Scientific exchange and intense discussion of this timely topic was fostered by bringing together renowned experts in their respective fields to present their thoughts and recent findings in the course of a plenary lecture and six themed sessions, accompanied by oral and poster contributions of young researchers. By targeting the topic of fungal virulence mechanisms from various angles and in the context of plant and human hosts, some common grounds and exciting perspectives could be deduced during this vibrant scientific event.

  18. Germany's Armed Forces in the Second World War: Manpower, Armaments, and Supply.

    ERIC Educational Resources Information Center

    Balsamo, Larry T.

    1991-01-01

    Discusses the state of Germany's armed forces in World War II. Describes Germany's progress from inferior weaponry and unprepared military at the beginning of the war to superior weapons and fighting. Stresses heavy German dependence on horse drawn supply. Credits Germany's defeat to human attrition accelerated by Hitler's operational leadership.…

  19. Germany's Persistent Balance-of-Payments Disequilibrium Revisited. German Studies Notes.

    ERIC Educational Resources Information Center

    Kindleberger, Charles P.

    This essay compares Germany's persistent financial disequilibrium with the balance of payments situation in the United States. Delivered at a Symposium on German Economic Growth and Stability, the author concentrates on Germany's balance of payments surplus and presents U.S. figures mainly as a point of comparison. The material on Germany has been…

  20. Germany: The Search for Unity.

    ERIC Educational Resources Information Center

    Blankenship, Glen, Ed.

    The 12 lessons in this collection are designed so that they may be used individually, integrated into the curriculum at appropriate places, or used as a complete unit. The lessons are entitled: (1) Impressions of Germany and Germans; (2) The Location and Population of Germany; (3) Pollution in Germany: A Complex Problems; (4) German Political…

  1. 78 FR 52759 - Brass Sheet and Strip from Germany: Rescission of Antidumping Duty Administrative Review; 2012-2013

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-26

    ... Germany: Rescission of Antidumping Duty Administrative Review; 2012-2013 AGENCY: Import Administration... from Germany for the period March 1, 2012, through February 28, 2013. DATES: Effective Date: August 26... 1, 2013, the Department initiated an administrative review of brass sheet and strip from Germany...

  2. 76 FR 42681 - Brass Sheet and Strip From Germany: Notice of Rescission of Antidumping Duty Administrative Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-19

    ... Germany: Notice of Rescission of Antidumping Duty Administrative Review AGENCY: Import Administration... antidumping duty order on brass sheet and strip from Germany. The review covers one producer/exporter of brass sheet and strip from Germany, Wieland-Werke AG (``Wieland''). Based on a timely withdrawal of the...

  3. Defense.gov Special Report: Travels with Carter - May 2013

    Science.gov Websites

    Germany Germany Flag of Djibouti Djibouti Flag of Afghanistan Afghanistan Top Stories Carter Wraps Up , Civilians Breedlove Takes Charge at European Command Carter Arrives in Germany for Eucom Change of Command Meetings Carter Attends Eucom Change of Command Ceremony in Stuttgart, Germany Travel Locations Travel

  4. 78 FR 73562 - Non-Oriented Electrical Steel From China, Germany, Japan, Korea, Sweden, and Taiwan; Determinations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-06

    ... (Preliminary)] Non-Oriented Electrical Steel From China, Germany, Japan, Korea, Sweden, and Taiwan... industry in the United States is materially injured by reason of imports from China, Germany, Japan, Korea... Taiwan and LTFV imports of non-oriented electrical steel from China, Germany, Japan, Korea, Sweden, and...

  5. History of modern genetics in Germany.

    PubMed

    Hammar, Friederike

    2002-01-01

    The history of modern genetics in Germany during the 20th century is a story of missed chances. In the USA the genetic revolution opened a fascinating new field for ambitious scientists and created a rapidly growing new industry. Meanwhile Germany stood aside, combating with political and social restrictions. Promising young scientists who wanted to work in the field left Germany for the US, and big companies moved their facilities out of the country. Up until the middle of the 1990s molecular biology in Germany remained a "sleeping beauty" even though many brilliant scientists did their jobs very well. Then a somewhat funny idea changed everything: the German minister for education and science proclaimed the BioRegio contest in order to award the most powerful biotechnology region in Germany concerning academia and especially industry. Since then Germany's biotechnology industry has grown constantly and rapidly due to the foundation of a number of small biotech companies; big companies have returned their interests and their investments to Germany, paralleled by an improvement in academic research because of more funding and better support especially for younger scientists. In respect to biotechnology and molecular biology, Germany is still a developing country, but it has started to move and to take its chances in an exciting global competition.

  6. Declining male births in Germany before and after reunification.

    PubMed

    Grech, Victor

    2013-01-01

    Male births occur 3% in excess of female births in mammals in a ratio (M/F) of 0.515. Many factors have been shown to influence this, including socioeconomic deprivation. This paper reviews live birth data for Germany over the period 1946-2009, and identifies secular trends in M/F pre- and post-reunification. The null hypothesis is that there were no differences between East and West Germany, geographically or temporally, before and after reunification. Annual data on male and female live births were obtained from the Human Mortality Database and analyzed with contingency tables. These data were available separately for East and West Germany (1950-1989). There was a significant decline in M/F in both German Republics overall and before reunification (p<0.0001). No decline was present after. Pre-reunification, West Germany had a lower overall M/F than East Germany (p=0.001). In conclusion, a declining M/F has been shown in many countries over the past decades. The two German Republics' M/F fell prior to reunification and the economic collapse of East Germany. Contracting societies that offer poor socioeconomic conditions (such as the communist former East Germany) may result in a decrease in M/F, but this is not reflected in the data, which show that M/F in West Germany prior to reunification was lower than in East Germany. This is not explicable with the contracting economies hypothesis; other and as yet unknown influences may have modified M/F trends anticipated by known variables.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salvagnini, Elena; Bosmans, Hilde; Marshall, Nicholas W.

    Purpose: The aim of this paper was to illustrate the value of the new metric effective detective quantum efficiency (eDQE) in relation to more established measures in the optimization process of two digital mammography systems. The following metrics were included for comparison against eDQE: detective quantum efficiency (DQE) of the detector, signal difference to noise ratio (SdNR), and detectability index (d′) calculated using a standard nonprewhitened observer with eye filter.Methods: The two systems investigated were the Siemens MAMMOMAT Inspiration and the Hologic Selenia Dimensions. The presampling modulation transfer function (MTF) required for the eDQE was measured using two geometries: amore » geometry containing scattered radiation and a low scatter geometry. The eDQE, SdNR, and d′ were measured for poly(methyl methacrylate) (PMMA) thicknesses of 20, 40, 60, and 70 mm, with and without the antiscatter grid and for a selection of clinically relevant target/filter (T/F) combinations. Figures of merit (FOMs) were then formed from SdNR and d′ using the mean glandular dose as the factor to express detriment. Detector DQE was measured at energies covering the range of typical clinically used spectra.Results: The MTF measured in the presence of scattered radiation showed a large drop at low spatial frequency compared to the low scatter method and led to a corresponding reduction in eDQE. The eDQE for the Siemens system at 1 mm{sup −1} ranged between 0.15 and 0.27, depending on T/F and grid setting. For the Hologic system, eDQE at 1 mm{sup −1} varied from 0.15 to 0.32, again depending on T/F and grid setting. The eDQE results for both systems showed that the grid increased the system efficiency for PMMA thicknesses of 40 mm and above but showed only small sensitivity to T/F setting. While results of the SdNR and d′ based FOMs confirmed the eDQE grid position results, they were also more specific in terms of T/F selection. For the Siemens system at 20 mm PMMA, the FOMs indicated Mo/Mo (grid out) as optimal while W/Rh (grid in) was the optimal configuration at 40, 60, and 70 mm PMMA. For the Hologic, the FOMs pointed to W/Rh (grid in) at 20 and 40 mm of PMMA while W/Ag (grid in) gave the highest FOM at 60 and 70 mm PMMA. Finally, DQE at 1 mm{sup −1} averaged for the four beam qualities studied was 0.44 ± 0.02 and 0.55 ± 0.03 for the Siemens and Hologic detectors, respectively, indicating only a small influence of energy on detector DQE.Conclusions: Both the DQE and eDQE data showed only a small sensitivity to T/F setting for these two systems. The eDQE showed clear preferences in terms of scatter reduction, being highest for the grid-in geometry for PMMA thicknesses of 40 mm and above. The SdNR and d′ based figures of merit, which contain additional weighting for contrast and dose, pointed to specific T/F settings for both systems.« less

  8. 77 FR 32507 - Brass Sheet and Strip From Germany: Notice of Rescission of Antidumping Duty Administrative Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-01

    ... Germany: Notice of Rescission of Antidumping Duty Administrative Review AGENCY: Import Administration... and strip from Germany for the period of review (``POR''), March 1, 2011, through February 29, 2012.\\1... brass sheet and strip from Germany: Aurubis Stolberg GmbH & Co. KG (``Aurubis''), Carl Schreiber GmbH...

  9. 78 FR 9674 - Ball Bearings and Parts Thereof From Germany: Preliminary Results of Antidumping Duty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-11

    ... Thereof From Germany: Preliminary Results of Antidumping Duty Administrative Review and Partial Rescission... antidumping duty order on ball bearings and parts thereof from Germany. The period of review (POR) is May 1... bearings and parts thereof from Germany as the conclusion of a sunset review. See Ball Bearings and Parts...

  10. 76 FR 35910 - Brass Sheet and Strip From France, Germany, Italy, and Japan; Notice of Commission Determinations...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-20

    ...)] Brass Sheet and Strip From France, Germany, Italy, and Japan; Notice of Commission Determinations To..., Germany, Italy, and Japan AGENCY: United States International Trade Commission. ACTION: Notice. SUMMARY... duty orders on brass sheet and strip from France, Germany, Italy, and Japan would be likely to lead to...

  11. 75 FR 41439 - Lightweight Thermal Paper from Germany: Extension of Time Limits for the Preliminary Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-16

    ... from Germany: Extension of Time Limits for the Preliminary Results of Antidumping Duty Administrative... paper from Germany (LTWP), covering the period November 20, 2008, to October 31, 2009. See Initiation of...'s sales were at prices less than the cost of production. See Lightweight Thermal Paper from Germany...

  12. 75 FR 27538 - Brass Sheet and Strip from Germany: Extension of Time Limit for the Final Results of Antidumping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-17

    ... Germany: Extension of Time Limit for the Final Results of Antidumping Duty Administrative Review AGENCY... administrative review of the antidumping duty order on brass sheet and strip from Germany covering one respondent... Sheet and Strip From Germany: Preliminary Results of Antidumping Duty Administrative Review, 75 FR 18801...

  13. [Fostering of health economics in Germany].

    PubMed

    Ulrich, V

    2012-05-01

    Health economics is now well established in Germany with the aim to apply economic tools to answer problems in health and health care. After a short review of the international development of health economics and the development in Germany in particular, the article looks at selected recent topics of health economic analysis in Germany (economic evaluation, industrial economics, health and education).

  14. 77 FR 23508 - Brass Sheet and Strip From France, Germany, Italy, and Japan

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-19

    ...)] Brass Sheet and Strip From France, Germany, Italy, and Japan Determination On the basis of the record \\1... antidumping duty orders on brass sheet and strip from France, Germany, Italy, and Japan would be likely to... from France, Germany, Italy, and Japan: Investigation Nos. 731-TA-313, 314, 317, and 379 (Third Review...

  15. 75 FR 81308 - Stainless Steel Sheet And Strip From Germany, Italy, Japan, Korea, Mexico, And Taiwan

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-27

    ...)] Stainless Steel Sheet And Strip From Germany, Italy, Japan, Korea, Mexico, And Taiwan AGENCY: United States... and strip from Germany, Italy, Japan, Korea, Mexico, and Taiwan. SUMMARY: The Commission hereby gives... strip from Germany, Italy, Japan, Korea, Mexico, and Taiwan would be likely to lead to continuation or...

  16. 75 FR 59744 - Stainless Steel Sheet and Strip From Germany, Italy, Japan, Korea, Mexico, and Taiwan

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-28

    ...)] Stainless Steel Sheet and Strip From Germany, Italy, Japan, Korea, Mexico, and Taiwan AGENCY: United States... duty orders on stainless steel sheet and strip from Germany, Italy, Japan, Korea, Mexico, and Taiwan... stainless steel sheet and strip from Germany, Italy, Japan, Korea, Mexico, and Taiwan would be likely to...

  17. European opportunities for fuel cell commercialisation

    NASA Astrophysics Data System (ADS)

    Gibbs, C. E.; Steel, M. C. F.

    1992-01-01

    The European electricity market is changing. This paper will look at the background to power generation in Europe and highlight the recent factors which have entered the market to promote change. The 1990s seem to offer great possibilities for fuel cell commercialisation. Awareness of environmental problems has never been greater and there is growing belief that fuel cell technology can contribute to solving some of these problems. Issues which have caused the power industry in Europe to re-think its methods of generation include: concern over increasing carbon dioxide emissions and their contribution to the greenhouse effect; increasing SO x and NO x emissions and the damage cause by acid rain; the possibility of adverse effects on health caused by high voltage transmission lines; environmental restrictions to the expansion of hydroelectric schemes; public disenchantment with nuclear power following the Chernobyl accident; avoidance of dependence on imported oil following the Gulf crisis and a desire for fuel flexibility. All these factors are hastening the search for clean, efficient, modular power generators which can be easily sited close to the electricity consumer and operated using a variety of fuels. It is not only the power industry which is changing. A tightening of the legislation concerning emissions from cars is encouraging European auto companies to develop electric vehicles, some of which may be powered by fuel cells. Political changes, such as the opening up of Eastern Europe will also expand the market for low-emission, efficient power plants as attempts are made to develop and clean up that region. Many Europeans organisations are re-awakening their interest, or strengthening their activities, in the area of fuel cells because of the increasing opportunities offered by the European market. While some companies have chosen to buy, test and demonstrate Japanese or American fuel cell stacks with the aim of gaining operational experience and developing European sub-systems, others have chosen to develop their own novel cell technology. This paper will survey the extent of the fuel cell activities in Europe and emphasise the particular markets which fuel cell manufacturers are targeting. Demand for fuel cells in defence and military applications will be the first sector to be commercially viable — European companies such as Siemens, Elenco and VSEL are already marketing AFC or PEM systems for naval and aerospace applications. The small-scale CHP sector is also a likely early market for fuel cell plant. Co-generation fuel cells are of great interest to gas companies like ENAGAS and British Gas looking to promote sales of gas by installing on-site gas-fired generators on their customers' premises. The market for utility scale fuel cell plants is expected to develop later in the decade. The largest demonstration planned for Europe is the 1 MW PAFC for Milan, due to come onstream in 1992. MBB GmbH is considering developing MW-scale MCFC plants with the US company ERC — a 2 MW demonstration is planned for the end of 1993. The potential market for utility fuel cells is large — installation rates could reach 500-1000 MW/year by the turn of the century. Fuel cells will probably not achieve significant use in transport applications in Europe until after the turn of the century unless very stringent emissions legislation for vehicles is introduced. The likely early markets for fuel cells in the transport sector seem to be for delivery and fleet vehicles. Examples of European projects in this area include the Amsterdam city bus project which will use Elenco's AFC technology and Siemens' fork lift truck which will incorporate a PEM fuel cell. Fuel cells also link conveniently with renewable energy systems — coupled with an electrolyser a fuel cell can store solar, wind or wave power. The electrolysis proces is used to generate hydrogen from water at times of surplus energy while the fuel cell consumes hydrogen fuel when demand for power exceeds supply. The SWB solar hydrogen project in Germany is testing PAFC and AFC stacks in this application. Several problems remain before fuel cell technology can fulfil its maximum potential market. For PAFC there is a need to reduce plant capital costs and to verify lifetimes and reliability. KTI's 25 kW demonstration at Delft and the Milan 1 MW plant will increase European knowledge and experience of PAFC plant operation. For MCFC there are materials problems to be solved and work needs to be carried out on the best way to scale up plants. Projects underway in the Netherlands, Germany, Italy and elsewhere should bring Europe to the forefront of MCFC technology. SOFC requires further study in the area of design configurations and fabrication techniques. Research on these aspects is underway in Denmark, Switzerland, Germany, the Netherlands and the UK. For PEM technology work on reducing precious metal loadings and selecting the best polymer membrane is required — an area in which Johnson Matthey is involved. For all fuel cell technologies there needs to be a greater awareness among power suppliers, consumers, legislators and environmentalists of the advantages that fuel cells can offer. The increase in activity among European organisations in developing, demonstrating, testing and optimising fuel cell systems will encourage a greater awareness of the technology and bring commercialisation closer to reality.

  18. [How do authors of systematic reviews restrict their literature searches when only studies from Germany should be included?

    PubMed

    Pieper, Dawid; Mathes, Tim; Palm, Rebecca; Hoffmann, Falk

    2016-11-01

    The use of search filters (e. g. for study types) facilitates the process of literature searching. Regional limits might be helpful depending on the research question. Regional search filters are already available for some regions, but not for Germany. Our aim is to give an overview of applied search strategies in systematic reviews (SRs) focusing on Germany. We searched Medline (via Pubmed) applying a focused search strategy to identify SRs focusing on Germany in January 2016. Study selection and data extraction were performed by two reviewers independently. The search strategies with a focus on Germany were analyzed in terms of reasonableness and completeness relying on the Peer Review of Electronic Search Strategies (PRESS) criteria. A narrative evidence synthesis was performed. In total, 36 SRs (13 written in English) were included. 78% were published in 2012 or later. The majority (89%) of SRs utilized at least two different sources for their search with databases and checking references being the most common. 17 SRs did not use any truncations, ten SRs did not restrict their search to Germany, six SRs reported to have searched for German OR Germany. Only ten articles searched for the term Germany (occasionally jointly with the term Deutschland) without any use of an adjective such as German. There is a high interest in regionally focused SRs. The identified search strategies revealed a need for improvement. It would be helpful to develop a regional search filter for Germany that is able to identify studies performed in Germany. Copyright © 2016. Published by Elsevier GmbH.

  19. Increasing use of radical prostatectomy for locally advanced prostate cancer in the USA and Germany: a comparative population-based study.

    PubMed

    Hager, B; Kraywinkel, K; Keck, B; Katalinic, A; Meyer, M; Zeissig, S R; Scheufele, R; Wirth, M P; Huber, J

    2017-03-01

    Current guidelines do not recommend a preferred treatment modality for locally advanced prostate cancer. The aim of the study was to compare treatment patterns found in the USA and Germany and to analyze possible trends over time. We compared 'Surveillance Epidemiology and End Results' (SEER) data (USA) with reports from four German federal epidemiological cancer registries (Eastern Germany, Bavaria, Rhineland-Palatinate, Schleswig-Holstein), both from 2004 to 2012. We defined locally advanced prostate cancer as clinical stage T3 or T4. Exclusion criteria were metastatic disease and age over 79 years. We identified 9127 (USA) and 11 051 (Germany) patients with locally advanced prostate cancer. The share was 2.1% in the USA compared with 6.0% in Germany (P<0.001). In the United States, the utilization of radiotherapy (RT) and radical prostatectomy (RP) was comparably high with 42.0% (RT) and 42.8% (RP). In Germany, the major treatment option was RP with 36.7% followed by RT with 22.1%. During the study period, the use of RP increased in both countries (USA P=0.001 and Germany P=0.003), whereas RT numbers declined (USA P=0.003 and Germany P=0.002). The share of adjuvant RT (aRT) was similar in both countries (USA 21.7% vs Germany 20.7%). We found distinctive differences in treating locally advanced prostate cancer between USA and Germany, but similar trends over time. In the last decade, a growing number of patients underwent RP as a possible first step within a multimodal concept.

  20. The Effects of China Entering the World Trade Organization on the United States’ Wireless Telecommunication Industry

    DTIC Science & Technology

    2003-12-01

    of the contracts awarded worldwide. Alcatel, Ericsson, Hauwei, NEC, Nokia, Nortel, Samsung , Siemens, and many other foreign companies have all...employs more than 12,000 employees in China. Motorola’s nine joint ventures in China include: Guangzhou Jinpeng Cellular Systems Company, Shanghai...Additionally, it currently employs more than 4,000 employees in China. Lucent’s six joint ventures in China include: Guoxin Lucent Technologies

  1. A computer simulation of the transient response of a 4 cylinder Stirling engine with burner and air preheater in a vehicle

    NASA Technical Reports Server (NTRS)

    Martini, W. R.

    1981-01-01

    A series of computer programs are presented with full documentation which simulate the transient behavior of a modern 4 cylinder Siemens arrangement Stirling engine with burner and air preheater. Cold start, cranking, idling, acceleration through 3 gear changes and steady speed operation are simulated. Sample results and complete operating instructions are given. A full source code listing of all programs are included.

  2. 76 FR 36901 - Brass Sheet and Strip From Germany: Extension of Time Limits for Preliminary and Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-23

    ... Germany: Extension of Time Limits for Preliminary and Final Results of Full Third Five-Year (``Sunset... a full sunset review of the antidumping duty order on brass sheet and strip from Germany. See... and Strip from Germany'' (June 7, 2011). Extension of Time Limits In accordance with section 751(c)(5...

  3. Disintegration and Violence among Migrants in Germany: Turkish and Russian Youths versus German Youths

    ERIC Educational Resources Information Center

    Baier, Dirk; Pfeiffer, Christian

    2008-01-01

    Turkish and Russian immigrants are the two largest groups of immigrants in Germany, but there are some important differences regarding their legal status. Although most of the Turkish adolescents were born in Germany, few of them have German citizenship. In contrast, most of the Russian youths were born outside Germany, but they mostly possess…

  4. Operation Eclipse; Appreciation and Outline Plan

    DTIC Science & Technology

    1945-04-25

    the boundaries of GERMANY . " . • g« Engineering tools, equipment, plant and stores0 specially, adapted for military purposes. Bridging material of...Control Council ( Germany ) Control Commission for Germany ’ (British Element) Supreme Hq AEF Mission (Denmark) Supreme Headquarters, Allied...Mission (Norway) U.S. Group Control Council (Austria) Control Commission for Germany (Air Division) War Office, MO 1 (SP) • ’ Control Commission for

  5. 76 FR 58299 - Brass Sheet and Strip From France, Germany, Italy, and Japan; Scheduling of a Full Five-Year...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-20

    ...)] Brass Sheet and Strip From France, Germany, Italy, and Japan; Scheduling of a Full Five-Year Review Concerning the Antidumping Duty Order on Brass Sheet and Strip From France, Germany, Italy, and Japan AGENCY... strip from France, Germany, Italy, and Japan would be likely to lead to continuation or recurrence of...

  6. Dental tourism from Switzerland to Germany.

    PubMed

    Gheorghe, Raluca; Zürcher, Andrea; Filippi, Andreas

    In recent years the topic of dental tourism has increasingly come into focus of dentists and patients. In the present study an attempt was made to find out, why patients from a restricted region travel to Germany for dental care. In five German dental clinics located in the border area between Switzerland and Germany, 272 women and 236 men ranging in age from 5 to 94 years, who had undergone at least one dental treatment in Germany, were questioned concerning the reasons for their visits. The interviews took place within a period of 6 months and relied on a questionnaire to collect data regarding sociodemographic features and patient behavior. In comparison to residents of Germany, patients residing in Switzerland took on considerably longer travel distances for the dental visit, in some cases more than 50km (9.7%). For patients residing in Switzerland the technical equipment of the practice was more important (p<0.001), whereas for residents of Germany the cost-effective treatment was decisive (p<0.05). Almost all patients residing in Switzerland (95.6%) confirmed that dental treatments in Germany were cheaper and that additional family members also came to Germany for dental care (65.0%).

  7. The Unequal Structure of the German Education System: Structural Reasons for Educational Failures of Turkish Youth in Germany.

    PubMed

    Fernandez-Kelly, Patricia

    The paper examines the educational experiences of Turkish youth in Germany with special references to the statistical data of Educational Report, PISA surveys. The results of the educational statistics of Germany show that more than group characteristics like social and cultural capital, structural and institutional factors (multi-track system with its selective mechanism, education policy, context of negative reception of Germany, institutional discrimination, and lack of intercultural curriculum) could have a decisive role in hampering the educational and labor market integration and social mobility of Turkish youth. This can be explained by a mix of factors: the education system which does not foster the educational progress of children from disadvantaged families; the high importance of school degrees for accessing to the vocational training system and the labor market; and direct and indirect institutional discrimination in educational area in Germany. Thus, this work suggests that the nature of the education system in Germany remains deeply "unequal," "hierarchical" and "exclusive." This study also demonstrates maintaining the marginalized position of Turkish children in Germany means that the country of origin or the immigrants' background is still a barrier to having access to education and the labor market of Germany.

  8. Web-based, virtual course units as a didactic concept for medical teaching.

    PubMed

    Schultze-Mosgau, Stefan; Zielinski, Thomas; Lochner, Jürgen

    2004-06-01

    The objective was to develop a web-based, virtual series of lectures for evidence-based, standardized knowledge transfer independent of location and time with possibilities for interactive participation and a concluding web-based online examination. Within the framework of a research project, specific Intranet and Internet capable course modules were developed together with a concluding examination. The concept of integrating digital and analogue course units supported by sound was based on FlashCam (Nexus Concepts), Flash MX (Macromedia), HTML and JavaScript. A Web server/SGI Indigo Unix server was used as a platform by the course provider. A variety of independent formats (swf, avi, mpeg, DivX, etc.) were integrated in the individual swf modules. An online examination was developed to monitor the learning effect. The examination papers are automatically forwarded by email after completion. The results are also returned to the user automatically after they have been processed by a key program and an evaluation program. The system requirements for the user PC have deliberately been kept low (Internet Explorer 5.0, Flash-Player 6, 56 kbit/s modem, 200 MHz PC). Navigation is intuitive. Users were provided with a technical online introduction and a FAQ list. Eighty-two students of dentistry in their 3rd to 5th years of study completed a questionnaire to assess the course content and the user friendliness (SPSS V11) with grades 1 to 6 (1 = 'excellent' and 6 = 'unsatisfactory'). The course units can be viewed under the URL: http://giga.rrze.uni-erlangen.de/movies/MKG/trailer and URL: http://giga.rrze.uni-erlangen.de/movies/MKG/demo/index. Some 89% of the students gave grades 1 (excellent) and 2 (good) for accessibility independent of time and 83% for access independent of location. Grades 1 and 2 were allocated for an objectivization of the knowledge transfer by 67% of the students and for the use of video sequences for demonstrating surgical techniques by 91% of the students. The course units were used as an optional method of studying by 87% of the students; 76% of the students made use of this facility from home; 83% of the students used Internet Explorer as a browser; 60% used online streaming and 35% downloading as the preferred method for data transfer. The course units contribute to an evidence-based objectivization of multimedia knowledge transfer independent of time and location. Online examinations permit automatic monitoring and evaluation of the learning effect. The modular structure permits easy updating of course contents. Hyperlinks with literature sources facilitate study.

  9. Validation of the Erlangen Test of Activities of Daily Living in Persons with Mild Dementia or Mild Cognitive Impairment (ETAM).

    PubMed

    Luttenberger, Katharina; Reppermund, Simone; Schmiedeberg-Sohn, Anke; Book, Stephanie; Graessel, Elmar

    2016-05-26

    There are currently no valid, fast, and easy-to-administer performance tests that are designed to assess the capacities to perform activities of daily living in persons with mild dementia and mild cognitive impairment (MCI). However, such measures are urgently needed for determining individual support needs as well as the efficacy of interventions. The aim of the present study was therefore to validate the Erlangen Test of Activities of Daily Living in Persons with Mild Dementia and Mild Cognitive Impairment (ETAM), a performance test that is based on the International Classification of Functioning and Health (ICF), which assesses the relevant domains of living in older adults with MCI and mild dementia who live independently. The 10 ICF-based items on the research version of the ETAM were tested in a final sample of 81 persons with MCI or mild dementia. The items were selected for the final version in accordance with 6 criteria: 1) all domains must be represented and have equal weight, 2) all items must load on the same factor, 3) item difficulties and item discriminatory powers, 4) convergent validity (Bayer Activities of Daily Living Scale [B-ADL]) and discriminant validity (Mini Mental State Examination [MMSE], Geriatric Depression Scale 15 [GDS-15]), 5) inter-rater reliabilities of the individual items, 6) as little material as possible. Retest reliability was also examined. Cohen's ds were calculated to determine the magnitudes of the differences in ETAM scores between participants diagnosed with different grades of severity of cognitive impairment. The final version of the ETAM consists of 6 items that cover the five ICF domains communication, mobility, self-care, domestic life (assessed by two 3-point items), and major life areas (specifically, the economic life sub-category) and load on a single factor. The maximum achievable score is 30 points (6 points per domain). The average administration time was 35 min, 19 of which were needed for pure item performance. The internal consistency was α = .71. The three-week test-retest reliability was r = .78, and the inter-rater reliability was r = .97. The ETAM also provided satisfactory discrimination between healthy individuals and persons with MCI or mild dementia as well as between persons with mild and moderate dementia. The 6-item final version of the ETAM shows satisfactory psychometric characteristics and can be administered quickly. It is therefore suitable for use in both clinical practice and research.

  10. Young Adults' Knowledge and Understanding of Personal Finance in Germany: Interviews with Experts and Test-Takers

    ERIC Educational Resources Information Center

    Happ, Roland; Förster, Manuel; Rüspeler, Ann-Katrin; Rothweiler, Jasmin

    2018-01-01

    In recent years, the financial education of young adults has gained importance in Germany; however, very few valid test instruments to assess the knowledge and understanding of personal finance are suitable for use in Germany. In this article, we describe results of a survey in which experts in Germany in areas related to personal finance judged…

  11. Interaction of Elastic Waves with Corrosion Damage

    DTIC Science & Technology

    2010-08-01

    Joachim Schneider -Gloetzl, Gloetzl GmbH, Rheinstetten, Germany Rainer Gloetzl, RG Research, Ettlingen, Germany...Katerina Krebber, Sascha Liehr, Mario Wendt, Aleksander Wosniok, BAM, Federal Institute for Materials, Research and Testing, Berlin, Germany

  12. 48 CFR 252.229-7001 - Tax Relief.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... claimed in Germany pursuant to the provisions of the Agreement Between the United States of America and Germany Concerning Tax Relief to be Accorded by Germany to United States Expenditures in the Interest of...

  13. WE-D-207-01: Background and Clinical Implementation of a Screening Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aberle, D.

    2015-06-15

    In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancermore » Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)« less

  14. Experimental assessment of out-of-field dose components in high energy electron beams used in external beam radiotherapy.

    PubMed

    Alabdoaburas, Mohamad M; Mege, Jean-Pierre; Chavaudra, Jean; Bezin, Jérémi Vũ; Veres, Atilla; de Vathaire, Florent; Lefkopoulos, Dimitri; Diallo, Ibrahima

    2015-11-08

    The purpose of this work was to experimentally investigate the out-of-field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT). The study was carried out for 6, 9, 12, and 18 MeV electron beams, on three different linear accelerators, each equipped with a specific applicator. Measurements were performed in a water phantom, at different depths, for different applicator sizes, and off-axis distances up to 70 cm from beam central axis (CAX). Thermoluminescent powder dosimeters (TLD-700) were used. For given cases, TLD measurements were compared to EBT3 films and parallel-plane ionization chamber measurements. Also, out-of-field doses at 10 cm depth, with and without applicator, were evaluated. With the Siemens applicators, a peak dose appears at about 12-15 cm out of the field edge, at 1 cm depth, for all field sizes and energies. For the Siemens Primus, with a 10 × 10 cm(²) applicator, this peak reaches 2.3%, 1%, 0.9% and 1.3% of the maximum central axis dose (Dmax) for 6, 9, 12 and 18 MeV electron beams, respectively. For the Siemens Oncor, with a 10 × 10 cm(²) applicator, this peak dose reaches 0.8%, 1%, 1.4%, and 1.6% of Dmax for 6, 9, 12, and 14 MeV, respectively, and these values increase with applicator size. For the Varian 2300C/D, the doses at 12.5 cm out of the field edge are 0.3%, 0.6%, 0.5%, and 1.1% of Dmax for 6, 9, 12, and 18 MeV, respectively, and increase with applicator size. No peak dose is evidenced for the Varian applicator for these energies. In summary, the out-of-field dose from electron beams increases with the beam energy and the applicator size, and decreases with the distance from the beam central axis and the depth in water. It also considerably depends on the applicator types. Our results can be of interest for the dose estimations delivered in healthy tissues outside the treatment field for the RT patient, as well as in studies exploring RT long-term effects.

  15. Experimental assessment of out‐of‐field dose components in high energy electron beams used in external beam radiotherapy

    PubMed Central

    Alabdoaburas, Mohamad M.; Mege, Jean‐Pierre; Chavaudra, Jean; Bezin, Jérémi Vũ; Veres, Attila; de Vathaire, Florent; Lefkopoulos, Dimitri

    2015-01-01

    The purpose of this work was to experimentally investigate the out‐of‐field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT). The study was carried out for 6, 9, 12, and 18 MeV electron beams, on three different linear accelerators, each equipped with a specific applicator. Measurements were performed in a water phantom, at different depths, for different applicator sizes, and off‐axis distances up to 70 cm from beam central axis (CAX). Thermoluminescent powder dosimeters (TLD‐700) were used. For given cases, TLD measurements were compared to EBT3 films and parallel‐plane ionization chamber measurements. Also, out‐of‐field doses at 10 cm depth, with and without applicator, were evaluated. With the Siemens applicators, a peak dose appears at about 12–15 cm out of the field edge, at 1 cm depth, for all field sizes and energies. For the Siemens Primus, with a 10×10cm2 applicator, this peak reaches 2.3%, 1%, 0.9% and 1.3% of the maximum central axis dose (Dmax) for 6, 9, 12 and 18 MeV electron beams, respectively. For the Siemens Oncor, with a 10×10cm2 applicator, this peak dose reaches 0.8%, 1%, 1.4%, and 1.6% of Dmax for 6, 9, 12, and 14 MeV, respectively, and these values increase with applicator size. For the Varian 2300C/D, the doses at 12.5 cm out of the field edge are 0.3%, 0.6%, 0.5%, and 1.1% of Dmax for 6, 9, 12, and 18 MeV, respectively, and increase with applicator size. No peak dose is evidenced for the Varian applicator for these energies. In summary, the out‐of‐field dose from electron beams increases with the beam energy and the applicator size, and decreases with the distance from the beam central axis and the depth in water. It also considerably depends on the applicator types. Our results can be of interest for the dose estimations delivered in healthy tissues outside the treatment field for the RT patient, as well as in studies exploring RT long‐term effects. PACS number(s): 87.53.Bn, 87.56.bd, 87.56.J‐ PMID:26699572

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancermore » Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)« less

  17. SU-F-I-49: Vendor-Independent, Model-Based Iterative Reconstruction On a Rotating Grid with Coordinate-Descent Optimization for CT Imaging Investigations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, S; Hoffman, J; McNitt-Gray, M

    Purpose: Iterative reconstruction methods show promise for improving image quality and lowering the dose in helical CT. We aim to develop a novel model-based reconstruction method that offers potential for dose reduction with reasonable computation speed and storage requirements for vendor-independent reconstruction from clinical data on a normal desktop computer. Methods: In 2012, Xu proposed reconstructing on rotating slices to exploit helical symmetry and reduce the storage requirements for the CT system matrix. Inspired by this concept, we have developed a novel reconstruction method incorporating the stored-system-matrix approach together with iterative coordinate-descent (ICD) optimization. A penalized-least-squares objective function with amore » quadratic penalty term is solved analytically voxel-by-voxel, sequentially iterating along the axial direction first, followed by the transaxial direction. 8 in-plane (transaxial) neighbors are used for the ICD algorithm. The forward problem is modeled via a unique approach that combines the principle of Joseph’s method with trilinear B-spline interpolation to enable accurate reconstruction with low storage requirements. Iterations are accelerated with multi-CPU OpenMP libraries. For preliminary evaluations, we reconstructed (1) a simulated 3D ellipse phantom and (2) an ACR accreditation phantom dataset exported from a clinical scanner (Definition AS, Siemens Healthcare). Image quality was evaluated in the resolution module. Results: Image quality was excellent for the ellipse phantom. For the ACR phantom, image quality was comparable to clinical reconstructions and reconstructions using open-source FreeCT-wFBP software. Also, we did not observe any deleterious impact associated with the utilization of rotating slices. The system matrix storage requirement was only 4.5GB, and reconstruction time was 50 seconds per iteration. Conclusion: Our reconstruction method shows potential for furthering research in low-dose helical CT, in particular as part of our ongoing development of an acquisition/reconstruction pipeline for generating images under a wide range of conditions. Our algorithm will be made available open-source as “FreeCT-ICD”. NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.« less

  18. TH-AB-207A-12: CT Lung Cancer Screening and the Effects of Further Dose Reduction On CAD Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, S; Lo, P; Hoffman, J

    Purpose: CT lung screening is already performed at low doses. In this study, we investigated the effects of further dose reduction on a lung-nodule CAD detection algorithm. Methods: The original raw CT data and images from 348 patients were obtained from our local database of National Lung Screening Trial (NLST) cases. 61 patients (17.5%) had at least one nodule reported on the NLST reader forms. All scans were acquired with fixed mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare). All images were reconstructed with 1-mm slice thickness, B50 kernel. Based onmore » a previously-published technique, we added noise to the raw data to simulate reduced-dose versions of each case at 50% and 25% of the original NLST dose (i.e. approximately 1.0 and 0.5 mGy CTDIvol). For each case at each dose level, a CAD detection algorithm was run and nodules greater than 4 mm in diameter were reported. These CAD results were compared to “truth”, defined as the approximate nodule centroids from the NLST forms. Sensitivities and false-positive rates (FPR) were calculated for each dose level, with a sub-analysis by nodule LungRADS category. Results: For larger category 4 nodules, median sensitivities were 100% at all three dose levels, and mean sensitivity decreased with dose. For the more challenging category 2 and 3 nodules, the dose dependence was less obvious. Overall, mean subject-level sensitivity varied from 38.5% at 100% dose to 40.4% at 50% dose, a difference of only 1.9%. However, median FPR quadrupled from 1 per case at 100% dose to 4 per case at 25% dose. Conclusions: Dose reduction affected nodule detectability differently depending on the LungRADS category, and FPR was very sensitive at sub-screening levels. Care should be taken to adapt CAD for the very challenging noise characteristics of screening. Funding support: NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.« less

  19. SU-G-206-15: Effects of Dose Reduction On Emphysema Score

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lo, P; Wahi-Anwar, M; Kim, H

    Purpose: The purpose of this study was to investigate the effects of reducing radiation dose levels on emphysema scores from lung cancer screening CT exams. Methods: 52 cases were selected from the National Lung Screening Trial (NLST) patients for which we had both the image series and the raw CT data. All scans were acquired with fixed effective mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare) using 120kV, 64×0.6mm collimation and pitch 1.0. All images were reconstructed with 1mm slice thickness, B50 kernel. Based on a previously-published technique, we added noisemore » to the raw data to simulate reduced-dose versions at 50% and 25% of the original dose (approximately 1.0- and 0.5-mGy CTDIvol). Lung segmentations were obtained via region growing from manual seed point at a threshold of 600HU followed by manual removal of trachea and major airways. Lung segmentations were only performed on original dose scans, and mapped to simulated reduced-dose scans. Emphysema scores based on relative area of lung with attenuation values lower than −950HU (RA950) were computed for all cases. Results: Average RA950 of all 50 cases were 31.6 (±5.5), 32.5 (±4.9) and 32.8 (±4.6) for 100%, 50% and 25% dose level respectively. The average absolute difference in RA950 between simulated and original dose scans were 1.0 (±0.7) and 1.4 (±1.1) for 50% and 25% dose level respectively. Conclusion: RA950 is relatively robust to dose level, with a difference of no more than 5 from the original dose scans. The average RA950 of this population was high for a two reasons: This was a high risk population of patients with substantial smoking history; The use of B50 kernel, which may be biased towards high emphysema scores. Further exploration with smoother kernels will be conducted in the future. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH grant support from U01 CA181156.« less

  20. SU-F-J-171: Robust Atlas Based Segmentation of the Prostate and Peripheral Zone Regions On MRI Utilizing Multiple MRI System Vendors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Padgett, K; Pollack, A; Stoyanova, R

    Purpose: Automatically generated prostate MRI contours can be used to aid in image registration with CT or ultrasound and to reduce the burden of contouring for radiation treatment planning. In addition, prostate and zonal contours can assist to automate quantitative imaging features extraction and the analyses of longitudinal MRI studies. These potential gains are limited if the solutions are not compatible across different MRI vendors. The goal of this study is to characterize an atlas based automatic segmentation procedure of the prostate collected on MRI systems from multiple vendors. Methods: The prostate and peripheral zone (PZ) were manually contoured bymore » an expert radiation oncologist on T2-weighted scans acquired on both GE (n=31) and Siemens (n=33) 3T MRI systems. A leave-one-out approach was utilized where the target subject is removed from the atlas before the segmentation algorithm is initiated. The atlas-segmentation method finds the best nine matched atlas subjects and then performs a normalized intensity-based free-form deformable registration of these subjects to the target subject. These nine contours are then merged into a single contour using Simultaneous Truth and Performance Level Estimation (STAPLE). Contour comparisons were made using Dice similarity coefficients (DSC) and Hausdorff distances. Results: Using the T2 FatSat (FS) GE datasets the atlas generated contours resulted in an average DSC of 0.83±0.06 for prostate, 0.57±0.12 for PZ and 0.75±0.09 for CG. Similar results were found when using the Siemens data with a DSC of 0.79±0.14 for prostate, 0.54±0.16 and 0.70±0.9. Contrast between prostate and surrounding anatomy and between the PZ and CG contours for both vendors demonstrated superior contrast separation; significance was found for all comparisons p-value < 0.0001. Conclusion: Atlas-based segmentation yielded promising results for all contours compared to expertly defined contours in both Siemens and GE 3T systems providing fast and automatic segmentation of the prostate. Funding Support, Disclosures, and Conflict of Interest: AS Nelson is a partial owner of MIM Software, Inc. AS Nelson, and A Swallen are current employees at MIM Software, Inc.« less

Top