Sample records for signature algorithm dsa

  1. Image-Based Airborne Sensors: A Combined Approach for Spectral Signatures Classification through Deterministic Simulated Annealing

    PubMed Central

    Guijarro, María; Pajares, Gonzalo; Herrera, P. Javier

    2009-01-01

    The increasing technology of high-resolution image airborne sensors, including those on board Unmanned Aerial Vehicles, demands automatic solutions for processing, either on-line or off-line, the huge amountds of image data sensed during the flights. The classification of natural spectral signatures in images is one potential application. The actual tendency in classification is oriented towards the combination of simple classifiers. In this paper we propose a combined strategy based on the Deterministic Simulated Annealing (DSA) framework. The simple classifiers used are the well tested supervised parametric Bayesian estimator and the Fuzzy Clustering. The DSA is an optimization approach, which minimizes an energy function. The main contribution of DSA is its ability to avoid local minima during the optimization process thanks to the annealing scheme. It outperforms simple classifiers used for the combination and some combined strategies, including a scheme based on the fuzzy cognitive maps and an optimization approach based on the Hopfield neural network paradigm. PMID:22399989

  2. Group Key Agreement Efficient in Communication

    DTIC Science & Technology

    2003-10-14

    Selected Areas in Communications, 17(9), September 1999. [13] David Chaum . Zero-knowledge undeniable signatures . In I.B. Damgard, editor, Advances in...sender with some sufficiently strong public key signature method such as DSA or RSA (and using a long-term private key).1 All receivers are required...to verify signatures on all received messages and check the aforementioned fields. Consequently, our security model is different from some recent

  3. [Affine transformation-based automatic registration for peripheral digital subtraction angiography (DSA)].

    PubMed

    Kong, Gang; Dai, Dao-Qing; Zou, Lu-Min

    2008-07-01

    In order to remove the artifacts of peripheral digital subtraction angiography (DSA), an affine transformation-based automatic image registration algorithm is introduced here. The whole process is described as follows: First, rectangle feature templates are constructed with their centers of the extracted Harris corners in the mask, and motion vectors of the central feature points are estimated using template matching technology with the similarity measure of maximum histogram energy. And then the optimal parameters of the affine transformation are calculated with the matrix singular value decomposition (SVD) method. Finally, bilinear intensity interpolation is taken to the mask according to the specific affine transformation. More than 30 peripheral DSA registrations are performed with the presented algorithm, and as the result, moving artifacts of the images are removed with sub-pixel precision, and the time consumption is less enough to satisfy the clinical requirements. Experimental results show the efficiency and robustness of the algorithm.

  4. Digital sorting of complex tissues for cell type-specific gene expression profiles.

    PubMed

    Zhong, Yi; Wan, Ying-Wooi; Pang, Kaifang; Chow, Lionel M L; Liu, Zhandong

    2013-03-07

    Cellular heterogeneity is present in almost all gene expression profiles. However, transcriptome analysis of tissue specimens often ignores the cellular heterogeneity present in these samples. Standard deconvolution algorithms require prior knowledge of the cell type frequencies within a tissue or their in vitro expression profiles. Furthermore, these algorithms tend to report biased estimations. Here, we describe a Digital Sorting Algorithm (DSA) for extracting cell-type specific gene expression profiles from mixed tissue samples that is unbiased and does not require prior knowledge of cell type frequencies. The results suggest that DSA is a specific and sensitivity algorithm in gene expression profile deconvolution and will be useful in studying individual cell types of complex tissues.

  5. A safe and effective management strategy for blunt cerebrovascular injury: Avoiding unnecessary anticoagulation and eliminating stroke.

    PubMed

    Shahan, Charles P; Magnotti, Louis J; Stickley, Shaun M; Weinberg, Jordan A; Hendrick, Leah E; Uhlmann, Rebecca A; Schroeppel, Thomas J; Hoit, Daniel A; Croce, Martin A; Fabian, Timothy C

    2016-06-01

    Few injuries have produced as much debate with respect to management as have blunt cerebrovascular injuries (BCVIs). Recent work (American Association for the Surgery of Trauma 2013) from our institution suggested that 64-channel multidetector computed tomographic angiography (CTA) could be the primary screening tool for BCVI. Consequently, our screening algorithm changed from digital subtraction angiography (DSA) to CTA, with DSA reserved for definitive diagnosis of BCVI following CTA-positive study results or unexplained neurologic findings. The current study was performed to evaluate outcomes, including the potential for missed clinically significant BCVI, since this new management algorithm was adopted. Patients who underwent DSA (positive CTA finding or unexplained neurologic finding) over an 18-month period subsequent to the previous study were identified. Screening and confirmatory test results, complications, and BCVI-related strokes were reviewed and compared. A total of 228 patients underwent DSA: 64% were male, with mean age and Injury Severity Score (ISS) of 43 years and 22, respectively. A total of 189 patients (83%) had a positive screening CTA result. Of these, DSA confirmed injury in 104 patients (55%); the remaining 85 patients (45%) (false-positive results) were found to have no injury on DSA. Five patients (4.8%) experienced BCVI-related strokes, unchanged from the previous study (3.9%, p = 0.756); two were symptomatic at trauma center presentation, and three occurred while receiving appropriate therapy. No patient with a negative screening CTA result experienced a stroke. This management scheme using 64-channel CTA for screening coupled with DSA for definitive diagnosis was proven to be safe and effective in identifying clinically significant BCVIs and maintaining a low stroke rate. Definitive diagnosis by DSA led to avoidance of potentially harmful anticoagulation in 45% of CTA-positive patients (false-positive results). No strokes resulted from injuries missed by CTA. Diagnostic study, level III.

  6. Incorporating DSA in multipatterning semiconductor manufacturing technologies

    NASA Astrophysics Data System (ADS)

    Badr, Yasmine; Torres, J. A.; Ma, Yuansheng; Mitra, Joydeep; Gupta, Puneet

    2015-03-01

    Multi-patterning (MP) is the process of record for many sub-10nm process technologies. The drive to higher densities has required the use of double and triple patterning for several layers; but this increases the cost of the new processes especially for low volume products in which the mask set is a large percentage of the total cost. For that reason there has been a strong incentive to develop technologies like Directed Self Assembly (DSA), EUV or E-beam direct write to reduce the total number of masks needed in a new technology node. Because of the nature of the technology, DSA cylinder graphoepitaxy only allows single-size holes in a single patterning approach. However, by integrating DSA and MP into a hybrid DSA-MP process, it is possible to come up with decomposition approaches that increase the design flexibility, allowing different size holes or bar structures by independently changing the process for every patterning step. A simple approach to integrate multi-patterning with DSA is to perform DSA grouping and MP decomposition in sequence whether it is: grouping-then-decomposition or decomposition-then-grouping; and each of the two sequences has its pros and cons. However, this paper describes why these intuitive approaches do not produce results of acceptable quality from the point of view of design compliance and we highlight the need for custom DSA-aware MP algorithms.

  7. Parameter estimation by Differential Search Algorithm from horizontal loop electromagnetic (HLEM) data

    NASA Astrophysics Data System (ADS)

    Alkan, Hilal; Balkaya, Çağlayan

    2018-02-01

    We present an efficient inversion tool for parameter estimation from horizontal loop electromagnetic (HLEM) data using Differential Search Algorithm (DSA) which is a swarm-intelligence-based metaheuristic proposed recently. The depth, dip, and origin of a thin subsurface conductor causing the anomaly are the parameters estimated by the HLEM method commonly known as Slingram. The applicability of the developed scheme was firstly tested on two synthetically generated anomalies with and without noise content. Two control parameters affecting the convergence characteristic to the solution of the algorithm were tuned for the so-called anomalies including one and two conductive bodies, respectively. Tuned control parameters yielded more successful statistical results compared to widely used parameter couples in DSA applications. Two field anomalies measured over a dipping graphitic shale from Northern Australia were then considered, and the algorithm provided the depth estimations being in good agreement with those of previous studies and drilling information. Furthermore, the efficiency and reliability of the results obtained were investigated via probability density function. Considering the results obtained, we can conclude that DSA characterized by the simple algorithmic structure is an efficient and promising metaheuristic for the other relatively low-dimensional geophysical inverse problems. Finally, the researchers after being familiar with the content of developed scheme displaying an easy to use and flexible characteristic can easily modify and expand it for their scientific optimization problems.

  8. Potential of dynamic spectrum allocation in LTE macro networks

    NASA Astrophysics Data System (ADS)

    Hoffmann, H.; Ramachandra, P.; Kovács, I. Z.; Jorguseski, L.; Gunnarsson, F.; Kürner, T.

    2015-11-01

    In recent years Mobile Network Operators (MNOs) worldwide are extensively deploying LTE networks in different spectrum bands and utilising different bandwidth configurations. Initially, the deployment is coverage oriented with macro cells using the lower LTE spectrum bands. As the offered traffic (i.e. the requested traffic from the users) increases the LTE deployment evolves with macro cells expanded with additional capacity boosting LTE carriers in higher frequency bands complemented with micro or small cells in traffic hotspot areas. For MNOs it is crucial to use the LTE spectrum assets, as well as the installed network infrastructure, in the most cost efficient way. The dynamic spectrum allocation (DSA) aims at (de)activating the available LTE frequency carriers according to the temporal and spatial traffic variations in order to increase the overall LTE system performance in terms of total network capacity by reducing the interference. This paper evaluates the DSA potential of achieving the envisaged performance improvement and identifying in which system and traffic conditions the DSA should be deployed. A self-optimised network (SON) DSA algorithm is also proposed and evaluated. The evaluations have been carried out in a hexagonal and a realistic site-specific urban macro layout assuming a central traffic hotspot area surrounded with an area of lower traffic with a total size of approximately 8 × 8 km2. The results show that up to 47 % and up to 40 % possible DSA gains are achievable with regards to the carried system load (i.e. used resources) for homogenous traffic distribution with hexagonal layout and for realistic site-specific urban macro layout, respectively. The SON DSA algorithm evaluation in a realistic site-specific urban macro cell deployment scenario including realistic non-uniform spatial traffic distribution shows insignificant cell throughput (i.e. served traffic) performance gains. Nevertheless, in the SON DSA investigations, a gain of up to 25 % has been observed when analysing the resource utilisation in the non-hotspot cells.

  9. Model-based guiding pattern synthesis for robust assembly of contact layers using directed self-assembly

    NASA Astrophysics Data System (ADS)

    Mitra, Joydeep; Torres, Andres; Ma, Yuansheng; Pan, David Z.

    2018-01-01

    Directed self-assembly (DSA) has emerged as one of the most compelling next-generation patterning techniques for sub 7 nm via or contact layers. A key issue in enabling DSA as a mainstream patterning technique is the generation of grapho-epitaxy-based guiding pattern (GP) shapes to assemble the contact patterns on target with high fidelity and resolution. Current GP generation is mostly empirical, and limited to a very small number of via configurations. We propose the first model-based GP synthesis algorithm and methodology for on-target and robust DSA, on general via pattern configurations. The final postoptical proximity correction-printed GPs derived from our original synthesized GPs are resilient to process variations and continue to maintain the same DSA fidelity in terms of placement error and target shape.

  10. Nonrigid Image Registration in Digital Subtraction Angiography Using Multilevel B-Spline

    PubMed Central

    2013-01-01

    We address the problem of motion artifact reduction in digital subtraction angiography (DSA) using image registration techniques. Most of registration algorithms proposed for application in DSA, have been designed for peripheral and cerebral angiography images in which we mainly deal with global rigid motions. These algorithms did not yield good results when applied to coronary angiography images because of complex nonrigid motions that exist in this type of angiography images. Multiresolution and iterative algorithms are proposed to cope with this problem, but these algorithms are associated with high computational cost which makes them not acceptable for real-time clinical applications. In this paper we propose a nonrigid image registration algorithm for coronary angiography images that is significantly faster than multiresolution and iterative blocking methods and outperforms competing algorithms evaluated on the same data sets. This algorithm is based on a sparse set of matched feature point pairs and the elastic registration is performed by means of multilevel B-spline image warping. Experimental results with several clinical data sets demonstrate the effectiveness of our approach. PMID:23971026

  11. Preoperative assessment of intracranial tumors with perfusion MR and a volumetric interpolated examination: a comparative study with DSA.

    PubMed

    Wetzel, Stephan G; Cha, Soonmee; Law, Meng; Johnson, Glyn; Golfinos, John; Lee, Peter; Nelson, Peter Kim

    2002-01-01

    In evaluating intracranial tumors, a safe low-cost alternative that provides information similar to that of digital subtraction angiography (DSA) may be of interest. Our purpose was to determine the utility and limitations of a combined MR protocol in assessing (neo-) vascularity in intracranial tumors and their relation to adjacent vessels and to compare the results with those of DSA. Twenty-two consecutive patients with an intracranial tumor who underwent preoperative stereoscopic DSA were examined with contrast-enhanced dynamic T2*-weighted perfusion MR imaging followed by a T1-weighted three-dimensional (3D) MR study (volumetric interpolated brain examination [VIBE]). The maximum relative cerebral blood volume (rCBV) of the tumor was compared with tumor vascularity at DSA. Critical vessel structures were defined in each patient, and VIBE images of these structures were compared with DSA findings. For full exploitation of the 3D data sets, maximum-intensity projection algorithms reconstructed in real time with any desired volume and orientation were used. Tumor blush scores at DSA were significantly correlated with the rCBV measurements (r = 0.75; P <.01, Spearman rank correlation coefficient). In 17 (77%) patients, VIBE provided all relevant information about the venous system, whereas information about critical arteries were partial in 50% of the cases and not relevant in the other 50%. A fast imaging protocol consisting of perfusion MR imaging and a volumetric MR acquisition provides some of the information about tumor (neo-) vascularity and adjacent vascular anatomy that can be obtained with conventional angiography. However, the MR protocol provides insufficient visualization of distal cerebral arteries.

  12. SU-E-I-26: Estimation of Micro-Angiographic Fluoroscope (MAF) Gain Settings for Digital Subtraction Angiography (DSA) Based on the Fluoroscopic Exposure.

    PubMed

    Ionita, C; Loughran, B; Nagesh, S Setlur; Jain, A; Bednarek, D; Rudin, S

    2012-06-01

    The MAF is a new high-resolution detector which is being clinically evaluated in neuro-vascular procedures. The detector contains a large-dynamic-range, high-sensitivity light image intensifier with variable gain. Since the MAF is a research prototype only partially integrated with the clinical system, x-ray technique parameters must be set manually. To improve workflow we developed an automatic method to estimate and set the proper LII voltage (MAF gain) for DSA acquisition based on the fluoroscopic parameters. The detector entrance exposure (XD) can be written as the x-ray tube output exposure (Xo) times an object attenuation factor and an inverse-square correction. If the object attenuation, scatter and distances are unchanged and the effect of x-ray kVp changes are neglected, then the DSA XD can be expressed as the ratio of Xo(DSA)/Xo(Fluoroscopy) multiplied with XD(fluoroscopy). We measured Xo for fluoroscopy and DSA for mAs and kVp ranges appropriate to neuro- vascular interventions and fit the data with a 2D function. To estimate the XD(Fluoroscopy) we derived a curve of XD versus LII-voltage for a mid- dynamic-range average pixel gray-level. Since the MAF system during clinical fluoroscopy automatically adjusts the LII voltage until the desired gray-level value is achieved, by reading that voltage we can estimate the XD(Fluoroscopy). Using the 2D-fit function, Xo(DSA) is automatically calculated for the kVp and mA values set and XD(DSA) can be estimated using the relation above. Using the inverse LII calibration curve, the proper LII-voltage can be determined for the desired average gray-level. The algorithm was implemented and evaluated in thirty-two in-vivo DSA runs on rabbits. The proper LII voltage was selected in all cases with no failures. Using the fluoroscopic LII gain setting to determine the appropriate DSA setting can greatly improve the workflow in clinical evaluations of the MAF. NIH Grants R01-EB008425, R01-EB002873 and an equipment grant from Toshiba Medical Systems Corp. © 2012 American Association of Physicists in Medicine.

  13. Multiresolution image registration in digital x-ray angiography with intensity variation modeling.

    PubMed

    Nejati, Mansour; Pourghassem, Hossein

    2014-02-01

    Digital subtraction angiography (DSA) is a widely used technique for visualization of vessel anatomy in diagnosis and treatment. However, due to unavoidable patient motions, both externally and internally, the subtracted angiography images often suffer from motion artifacts that adversely affect the quality of the medical diagnosis. To cope with this problem and improve the quality of DSA images, registration algorithms are often employed before subtraction. In this paper, a novel elastic registration algorithm for registration of digital X-ray angiography images, particularly for the coronary location, is proposed. This algorithm includes a multiresolution search strategy in which a global transformation is calculated iteratively based on local search in coarse and fine sub-image blocks. The local searches are accomplished in a differential multiscale framework which allows us to capture both large and small scale transformations. The local registration transformation also explicitly accounts for local variations in the image intensities which incorporated into our model as a change of local contrast and brightness. These local transformations are then smoothly interpolated using thin-plate spline interpolation function to obtain the global model. Experimental results with several clinical datasets demonstrate the effectiveness of our algorithm in motion artifact reduction.

  14. Correlation Between Contrast Time-Density Time on Digital Subtraction Angiography and Flow: An in Vitro Study.

    PubMed

    Brunozzi, Denise; Shakur, Sophia F; Ismail, Rahim; Linninger, Andreas; Hsu, Chih-Yang; Charbel, Fady T; Alaraj, Ali

    2018-02-01

    Digital subtraction angiography (DSA) provides an excellent anatomic characterization of cerebral vasculature, but hemodynamic assessment is often qualitative and subjective. Various clinical algorithms have been produced to semiquantify flow from the data obtained from DSA, but few have tested them against reliable flow values. An arched flow model was created and injected with contrast material. Seventeen injections were acquired in anterior-posterior and lateral DSA projections, and 4 injections were acquired in oblique projection. Image intensity change over the angiogram cycle of each DSA run was analyzed through a custom MATLAB code. Time-density plots obtained were divided into 3 components (time-density times, TDTs): TDT 10%-100% (time needed for contrast material to change image intensity from 10% to 100%), TDT 100%-10% (time needed for contrast material to change image intensity from 100% to 10%), and TDT 25%-25% (time needed for contrast material to change from 25% image intensity to 25%). Time-density index (TDI) was defined as model cross-sectional area to TDT ratio, and it was measured against different flow rates. TDI 10%-100% , TDI 100%-10% , and TDI 25%-25% all correlated significantly with flow (P < 0.001). TDI 10%-100% , TDI 100%-10% , and TDI 25%-25% showed, respectively, a correlation coefficient of 0.91, 0.91, and 0.97 in the anterior-posterior DSA projections (P < 0.001). In the lateral DSA projection, TDI 100%-10% showed a weaker correlation (r = 0.57; P = 0.03). Also in the oblique DSA projection, TDIs correlated significantly with flow. TDI on DSA correlates significantly with flow. Although in vitro studies might overlook conditions that occur in patients, this method appears to correlate with the flow and could offer a semiquantitative method to evaluate the cerebral blood flow. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Anomalous Transport of High Energy Cosmic Rays in Galactic Superbubbles

    NASA Technical Reports Server (NTRS)

    Barghouty, Nasser F.

    2014-01-01

    High-energy cosmic rays may exhibit anomalous transport as they traverse and are accelerated by a collection of supernovae explosions in a galactic superbubble. Signatures of this anomalous transport can show up in the particles' evolution and their spectra. In a continuous-time-random- walk (CTRW) model assuming standard diffusive shock acceleration theory (DSA) for each shock encounter, and where the superbubble (an OB stars association) is idealized as a heterogeneous region of particle sources and sinks, acceleration and transport in the superbubble can be shown to be sub-diffusive. While the sub-diffusive transport can be attributed to the stochastic nature of the acceleration time according to DSA theory, the spectral break appears to be an artifact of transport in a finite medium. These CTRW simulations point to a new and intriguing phenomenon associated with the statistical nature of collective acceleration of high energy cosmic rays in galactic superbubbles.

  16. Elaboration of a semi-automated algorithm for brain arteriovenous malformation segmentation: initial results.

    PubMed

    Clarençon, Frédéric; Maizeroi-Eugène, Franck; Bresson, Damien; Maingreaud, Flavien; Sourour, Nader; Couquet, Claude; Ayoub, David; Chiras, Jacques; Yardin, Catherine; Mounayer, Charbel

    2015-02-01

    The purpose of our study was to distinguish the different components of a brain arteriovenous malformation (bAVM) on 3D rotational angiography (3D-RA) using a semi-automated segmentation algorithm. Data from 3D-RA of 15 patients (8 males, 7 females; 14 supratentorial bAVMs, 1 infratentorial) were used to test the algorithm. Segmentation was performed in two steps: (1) nidus segmentation from propagation (vertical then horizontal) of tagging on the reference slice (i.e., the slice on which the nidus had the biggest surface); (2) contiguity propagation (based on density and variance) from tagging of arteries and veins distant from the nidus. Segmentation quality was evaluated by comparison with six frame/s DSA by two independent reviewers. Analysis of supraselective microcatheterisation was performed to dispel discrepancy. Mean duration for bAVM segmentation was 64 ± 26 min. Quality of segmentation was evaluated as good or fair in 93% of cases. Segmentation had better results than six frame/s DSA for the depiction of a focal ectasia on the main draining vein and for the evaluation of the venous drainage pattern. This segmentation algorithm is a promising tool that may help improve the understanding of bAVM angio-architecture, especially the venous drainage. • The segmentation algorithm allows for the distinction of the AVM's components • This algorithm helps to see the venous drainage of bAVMs more precisely • This algorithm may help to reduce the treatment-related complication rate.

  17. Blood flow quantification using 1D CFD parameter identification

    NASA Astrophysics Data System (ADS)

    Brosig, Richard; Kowarschik, Markus; Maday, Peter; Katouzian, Amin; Demirci, Stefanie; Navab, Nassir

    2014-03-01

    Patient-specific measurements of cerebral blood flow provide valuable diagnostic information concerning cerebrovascular diseases rather than visually driven qualitative evaluation. In this paper, we present a quantitative method to estimate blood flow parameters with high temporal resolution from digital subtraction angiography (DSA) image sequences. Using a 3D DSA dataset and a 2D+t DSA sequence, the proposed algorithm employs a 1D Computational Fluid Dynamics (CFD) model for estimation of time-dependent flow values along a cerebral vessel, combined with an additional Advection Diffusion Equation (ADE) for contrast agent propagation. The CFD system, followed by the ADE, is solved with a finite volume approximation, which ensures the conservation of mass. Instead of defining a new imaging protocol to obtain relevant data, our cost function optimizes the bolus arrival time (BAT) of the contrast agent in 2D+t DSA sequences. The visual determination of BAT is common clinical practice and can be easily derived from and be compared to values, generated by a 1D-CFD simulation. Using this strategy, we ensure that our proposed method fits best to clinical practice and does not require any changes to the medical work flow. Synthetic experiments show that the recovered flow estimates match the ground truth values with less than 12% error in the mean flow rates.

  18. Image Processing Of Images From Peripheral-Artery Digital Subtraction Angiography (DSA) Studies

    NASA Astrophysics Data System (ADS)

    Wilson, David L.; Tarbox, Lawrence R.; Cist, David B.; Faul, David D.

    1988-06-01

    A system is being developed to test the possibility of doing peripheral, digital subtraction angiography (DSA) with a single contrast injection using a moving gantry system. Given repositioning errors that occur between the mask and contrast-containing images, factors affecting the success of subtractions following image registration have been investigated theoretically and experimentally. For a 1 mm gantry displacement, parallax and geometric image distortion (pin-cushion) both give subtraction errors following registration that are approximately 25% of the error resulting from no registration. Image processing techniques improve the subtractions. The geometric distortion effect is reduced using a piece-wise, 8 parameter unwarping method. Plots of image similarity measures versus pixel shift are well behaved and well fit by a parabola, leading to the development of an iterative, automatic registration algorithm that uses parabolic prediction of the new minimum. The registration algorithm converges quickly (less than 1 second on a MicroVAX) and is relatively immune to the region of interest (ROI) selected.

  19. Designing algorithm visualization on mobile platform: The proposed guidelines

    NASA Astrophysics Data System (ADS)

    Supli, A. A.; Shiratuddin, N.

    2017-09-01

    This paper entails an ongoing study about the design guidelines of algorithm visualization (AV) on mobile platform, helping students learning data structures and algorithm (DSA) subject effectively. Our previous review indicated that design guidelines of AV on mobile platform are still few. Mostly, previous guidelines of AV are developed for AV on desktop and website platform. In fact, mobile learning has been proved to enhance engagement in learning circumstances, and thus effect student's performance. In addition, the researchers highly recommend including UI design and Interactivity in designing effective AV system. However, the discussions of these two aspects in previous AV design guidelines are not comprehensive. The UI design in this paper describes the arrangement of AV features in mobile environment, whereas interactivity is about the active learning strategy features based on learning experiences (how to engage learners). Thus, this study main objective is to propose design guidelines of AV on mobile platform (AVOMP) that entails comprehensively UI design and interactivity aspects. These guidelines are developed through content analysis and comparative analysis from various related studies. These guidelines are useful for AV designers to help them constructing AVOMP for various topics on DSA.

  20. Interest of convex spherical anamorphosis in better understanding of brain AVMs' angioarchitecture.

    PubMed

    Clarençon, Frédéric; Maizeroi-Eugène, Franck; Maingreaud, Flavien; Bresson, Damien; Ayoub, David; Sourour, Nader-Antoine; Menjot de Champfleur, Nicolas; Chiras, Jacques; Yardin, Catherine; Mounayer, Charbel

    2016-09-01

    Convex spherical anamorphosis is a barrel distortion that consists of the application of a plane surface on a convex hemisphere. Applied in vascular imaging of brain arteriovenous malformations (bAVMs), this deformation may help to 'spread' the nidus and surrounding vessels (arteries/veins) and thus to differentiate the different components of bAVMs more accurately. The imaging data from 15 patients (8 male, 7 female; 14 supratentorial bAVMs, 1 infratentorial) were used to test the algorithm. The algorithm was applied to three-dimensional rotational angiography (3D-RA) volume rendering reconstructions in anteroposterior, lateral and oblique views and compared with regular 3D-RA and DSA. Arterial feeder and draining vein count and quality visualization of the main draining vein and intranidal aneurysms were compared between the three imaging techniques. Anamorphosis was able to depict more arterial feeders than 3D-RA alone (p=0.027). There was no statistically significant difference between 6 f/s DSA and anamorphosis for arterial feeder count. No difference was observed in draining vein count between the three imaging modalities. Visualization of the precise origin of the main draining vein was considered to be good in 67% of the cases with anamorphosis versus 47% and 33% for 6 f/s DSA and 3D-RA alone, respectively. Intranidal aneurysms were accurately depicted by anamorphosis (2 cases), whereas 6 f/s DSA and 3D-RA showed doubtful images in one and two additional cases, respectively, which were finally confirmed as focal venous ectasias on supraselective injection. Anamorphosis can help to visualize more precisely the main draining vein origin of the bAVM and depict more accurately intranidal aneurysms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Comparison of RF spectrum prediction methods for dynamic spectrum access

    NASA Astrophysics Data System (ADS)

    Kovarskiy, Jacob A.; Martone, Anthony F.; Gallagher, Kyle A.; Sherbondy, Kelly D.; Narayanan, Ram M.

    2017-05-01

    Dynamic spectrum access (DSA) refers to the adaptive utilization of today's busy electromagnetic spectrum. Cognitive radio/radar technologies require DSA to intelligently transmit and receive information in changing environments. Predicting radio frequency (RF) activity reduces sensing time and energy consumption for identifying usable spectrum. Typical spectrum prediction methods involve modeling spectral statistics with Hidden Markov Models (HMM) or various neural network structures. HMMs describe the time-varying state probabilities of Markov processes as a dynamic Bayesian network. Neural Networks model biological brain neuron connections to perform a wide range of complex and often non-linear computations. This work compares HMM, Multilayer Perceptron (MLP), and Recurrent Neural Network (RNN) algorithms and their ability to perform RF channel state prediction. Monte Carlo simulations on both measured and simulated spectrum data evaluate the performance of these algorithms. Generalizing spectrum occupancy as an alternating renewal process allows Poisson random variables to generate simulated data while energy detection determines the occupancy state of measured RF spectrum data for testing. The results suggest that neural networks achieve better prediction accuracy and prove more adaptable to changing spectral statistics than HMMs given sufficient training data.

  2. DSA process window expansion with novel DSA track hardware

    NASA Astrophysics Data System (ADS)

    Harumoto, Masahiko; Stokes, Harold; Tanaka, Yuji; Kaneyama, Koji; Pieczulewski, Chalres; Asai, Masaya; Argoud, Maxime; Servin, Isabelle; Chamiot-Maitral, Gaëlle; Claveau, Guillaume; Tiron, Raluca; Cayrefourcq, Ian

    2017-03-01

    PS-b-PMMA block copolymer is a well-known DSA material, and there are many DSA patterning methods that make effective the use of such 1st generation materials. Consequently, this variety of patterning methods opens a wide array of possibilities for DSA application[1-4]. Last year, during the inaugural International DSA Symposium, researchers and lithographers concurred on common key issues for DSA patterning methods such as: defect density, LWR, placement error, etc. Defect density was specifically expressed as the biggest obstacle for new processes. Coat-Develop track systems contribute to the DSA pattern fabrication and also influence the DSA pattern performances[4]. In this study, defectivity was investigated using an atmosphere-controlled chamber on the SOKUDO DUO track. As an initial step for expanding the DSA process window, fingerprint patterns were used for various atmospheric conditions during DSA self-assembly annealing. In this study, we will demonstrate an improved DSA process window, and then we will discuss the mechanism for this atmospheric effect.

  3. Intermediate-term graft loss after renal transplantation is associated with both donor-specific antibody and acute rejection.

    PubMed

    Devos, Jennifer M; Gaber, Ahmed Osama; Teeter, Larry D; Graviss, Edward A; Patel, Samir J; Land, Geoffrey A; Moore, Linda W; Knight, Richard J

    2014-03-15

    Renal transplant recipients with de novo DSA (dDSA) experience higher rates of rejection and worse graft survival than dDSA-free recipients. This study presents a single-center review of dDSA monitoring in a large, multi-ethnic cohort of renal transplant recipients. The authors performed a nested case-control study of adult kidney and kidney-pancreas recipients from July 2007 through July 2011. Cases were defined as dDSA-positive whereas controls were all DSA-negative transplant recipients. DSA were determined at 1, 3, 6, 9, and 12 months posttransplant, and every 6 months thereafter. Of 503 recipients in the analysis, 24% developed a dDSA, of whom 73% had dDSA against DQ antigen. Median time to dDSA was 6.1 months (range 0.2-44.6 months). After multivariate analysis, African American race, kidney-pancreas recipient, and increasing numbers of human leukocyte antigen mismatches were independent risk factors for dDSA. Recipients with dDSA were more likely to suffer an acute rejection (AR) (35% vs. 10%, P<0.001), an antibody-mediated AR (16% vs. 0.3%, P<0.001), an AR ascribed to noncompliance (8% vs. 2%, P=0.001), and a recurrent AR (6% vs. 1%, P=0.002) than dDSA-negative recipients. At a median follow-up of 31 months, the death-censored actuarial graft survival of dDSA recipients was worse than the DSA-free cohort (P=0.002). Yet, for AR-free recipients, there was no difference in graft survival between cohorts (P=0.66). Development of dDSA was associated with an increased incidence of graft loss, yet the detrimental effect of dDSA was limited in the intermediate term to recipients with AR.

  4. De Novo DQ Donor-Specific Antibodies Are Associated with Chronic Lung Allograft Dysfunction after Lung Transplantation.

    PubMed

    Tikkanen, Jussi M; Singer, Lianne G; Kim, S Joseph; Li, Yanhong; Binnie, Matthew; Chaparro, Cecilia; Chow, Chung-Wai; Martinu, Tereza; Azad, Sassan; Keshavjee, Shaf; Tinckam, Kathryn

    2016-09-01

    Despite increasing evidence about the role of donor-specific human leukocyte antigen (HLA) antibodies in transplant outcomes, the incidence and impact of de novo donor-specific antibodies (dnDSA) after lung transplantation remains unclear. To describe the incidence, characteristics, and impact of dnDSA after lung transplantation. We investigated a single-center cohort of 340 lung transplant recipients undergoing transplant during 2008 to 2011. All patients underwent HLA-antibody testing quarterly pretransplant and at regular intervals over the first 24 months after transplant. The patients received modified immunosuppression depending on their pretransplant sensitization status. Risk factors for dnDSA development, as well as the associations of dnDSA with patient survival and chronic lung allograft dysfunction (CLAD), were determined using multivariable analysis. The cumulative incidence of dnDSA was 47% at a median of 86 days (range, 44-185 d) after lung transplantation. Seventy-six percent of recipients with dnDSA had DQ-DSA. Male sex and the use of ex vivo lung perfusion were associated with an increased risk of dnDSA, whereas increased HLA-DQB1 matching was protective. DQ-dnDSA preceded or coincided with the diagnosis of CLAD in all cases. Developing dnDSA (vs. no dnDSA) was associated with a twofold increased risk of CLAD (hazard ratio, 2.04; 95% confidence interval, 1.13-3.69). This association appeared to be driven by the development of DQ-dnDSA. dnDSA are common after lung transplantation, with the majority being DQ DSA. DQ-dnDSA are associated with an increased risk of CLAD. Strategies to prevent or treat DQ-dnDSA may improve outcomes for lung transplant recipients.

  5. N7 logic via patterning using templated DSA: implementation aspects

    NASA Astrophysics Data System (ADS)

    Bekaert, J.; Doise, J.; Gronheid, R.; Ryckaert, J.; Vandenberghe, G.; Fenger, G.; Her, Y. J.; Cao, Y.

    2015-07-01

    In recent years, major advancements have been made in the directed self-assembly (DSA) of block copolymers (BCP). Insertion of DSA for IC fabrication is seriously considered for the 7 nm node. At this node the DSA technology could alleviate costs for multiple patterning and limit the number of masks that would be required per layer. At imec, multiple approaches for inserting DSA into the 7 nm node are considered. One of the most straightforward approaches for implementation would be for via patterning through templated DSA; a grapho-epitaxy flow using cylindrical phase BCP material resulting in contact hole multiplication within a litho-defined pre-pattern. To be implemented for 7 nm node via patterning, not only the appropriate process flow needs to be available, but also DSA-aware mask decomposition is required. In this paper, several aspects of the imec approach for implementing templated DSA will be discussed, including experimental demonstration of density effect mitigation, DSA hole pattern transfer and double DSA patterning, creation of a compact DSA model. Using an actual 7 nm node logic layout, we derive DSA-friendly design rules in a logical way from a lithographer's view point. A concrete assessment is provided on how DSA-friendly design could potentially reduce the number of Via masks for a place-and-routed N7 logic pattern.

  6. Characteristics of a New X-Ray Imaging System for Interventional Procedures: Improved Image Quality and Reduced Radiation Dose.

    PubMed

    Schernthaner, Ruediger E; Haroun, Reham R; Nguyen, Sonny; Duran, Rafael; Sohn, Jae Ho; Sahu, Sonia; Chapiro, Julius; Zhao, Yan; Radaelli, Alessandro; van der Bom, Imramsjah M; Mauti, Maria; Hong, Kelvin; Geschwind, Jean-François H; Lin, MingDe

    2018-03-01

    To compare image quality and radiation exposure between a new angiographic imaging system and the preceding generation system during uterine artery embolization (UAE). In this retrospective, IRB-approved two-arm study, 54 patients with symptomatic uterine fibroids were treated with UAE on two different angiographic imaging systems. The new system includes optimized acquisition parameters and real-time image processing algorithms. Air kerma (AK), dose area product (DAP) and acquisition time for digital fluoroscopy (DF) and digital subtraction angiography (DSA) were recorded. Body mass index was noted as well. DF image quality was assessed objectively by image noise measurements. DSA image quality was rated by two blinded, independent readers on a four-rank scale. Statistical differences were assessed with unpaired t tests and Wilcoxon rank-sum tests. There was no significant difference between the patients treated on the new (n = 36) and the old system (n = 18) regarding age (p = 0.10), BMI (p = 0.18), DF time (p = 0.35) and DSA time (p = 0.17). The new system significantly reduced the cumulative AK and DAP by 64 and 72%, respectively (median 0.58 Gy and 145.9 Gy*cm 2 vs. 1.62 Gy and 526.8 Gy*cm 2 , p < 0.01 for both). Specifically, DAP for DF and DSA decreased by 59% (75.3 vs. 181.9 Gy*cm 2 , p < 0.01) and 78% (67.6 vs. 312.2 Gy*cm 2 , p < 0.01), respectively. The new system achieved a significant decrease in DF image noise (p < 0.01) and a significantly better DSA image quality (p < 0.01). The new angiographic imaging system significantly improved image quality and reduced radiation exposure during UAE procedures.

  7. Parametric color coding of digital subtraction angiography.

    PubMed

    Strother, C M; Bender, F; Deuerling-Zheng, Y; Royalty, K; Pulfer, K A; Baumgart, J; Zellerhoff, M; Aagaard-Kienitz, B; Niemann, D B; Lindstrom, M L

    2010-05-01

    Color has been shown to facilitate both visual search and recognition tasks. It was our purpose to examine the impact of a color-coding algorithm on the interpretation of 2D-DSA acquisitions by experienced and inexperienced observers. Twenty-six 2D-DSA acquisitions obtained as part of routine clinical care from subjects with a variety of cerebrovascular disease processes were selected from an internal data base so as to include a variety of disease states (aneurysms, AVMs, fistulas, stenosis, occlusions, dissections, and tumors). Three experienced and 3 less experienced observers were each shown the acquisitions on a prerelease version of a commercially available double-monitor workstation (XWP, Siemens Healthcare). Acquisitions were presented first as a subtracted image series and then as a single composite color-coded image of the entire acquisition. Observers were then asked a series of questions designed to assess the value of the color-coded images for the following purposes: 1) to enhance their ability to make a diagnosis, 2) to have confidence in their diagnosis, 3) to plan a treatment, and 4) to judge the effect of a treatment. The results were analyzed by using 1-sample Wilcoxon tests. Color-coded images enhanced the ease of evaluating treatment success in >40% of cases (P < .0001). They also had a statistically significant impact on treatment planning, making planning easier in >20% of the cases (P = .0069). In >20% of the examples, color-coding made diagnosis and treatment planning easier for all readers (P < .0001). Color-coding also increased the confidence of diagnosis compared with the use of DSA alone (P = .056). The impact of this was greater for the naïve readers than for the expert readers. At no additional cost in x-ray dose or contrast medium, color-coding of DSA enhanced the conspicuity of findings on DSA images. It was particularly useful in situations in which there was a complex flow pattern and in evaluation of pre- and posttreatment acquisitions. Its full potential remains to be defined.

  8. Incidence and Factors Associated with De Novo DSA After BK Viremia in Renal Transplant Recipients.

    PubMed

    Patel, Samir J; Kuten, Samantha A; Knight, Richard J; Graviss, Edward A; Nguyen, Duc; Gaber, A Osama

    2016-01-01

    BK polyomavirus infection and de novo donor-human leukocyte antigen (HLA) specific antibodies (dnDSA) are two well-known and distinct complications occurring after kidney transplantation. Recent literature suggests an association between the two events. This study aims to examine the relationship between BK viremia (BKV) and dnDSA and to identify potential risk factors for dnDSA following BKV in kidney transplant recipients. A retrospective review of 1019 recipients from Houston Methodist Hospital was conducted. All patients underwent routine screening for BKV and dnDSA. Median follow-up was 44 months. BKV was detected in 186 (18%) patients at a median of 107 (82-205) days post-transplant. dnDSA occurred in 283 (28%) patients at a median of 272 (62-575) days post-transplant. Of the 69 dnDSA-positive/BKV-positive patients, dnDSA detection occurred after BKV onset in 46 patients. Thus, 46 (28%) previously DSA-negative patients later became dnDSA-positive following BKV, not significantly different from the rate seen in BKV-negative patients (26%; p=0.5). Median time to DSA detection following BKV onset was 232 days (interquartile range, 119-460) post-BKV detection. Multivariate analysis revealed a greater number of HLA mismatches and viral clearance as risk factors for development of dnDSA following BKV, whereas delayed graft function was associated with a lower risk of dnDSA. In conclusion, despite being considered a result of over-immunosuppression, BKV can still be followed by dnDSA in a substantial proportion of patients. Monitoring for dnDSA in patients being managed for BKV may be warranted. Copyright© 2017 by the Terasaki Research Institute.

  9. Dynamic Speed Adaptation for Path Tracking Based on Curvature Information and Speed Limits.

    PubMed

    Gámez Serna, Citlalli; Ruichek, Yassine

    2017-06-14

    A critical concern of autonomous vehicles is safety. Different approaches have tried to enhance driving safety to reduce the number of fatal crashes and severe injuries. As an example, Intelligent Speed Adaptation (ISA) systems warn the driver when the vehicle exceeds the recommended speed limit. However, these systems only take into account fixed speed limits without considering factors like road geometry. In this paper, we consider road curvature with speed limits to automatically adjust vehicle's speed with the ideal one through our proposed Dynamic Speed Adaptation (DSA) method. Furthermore, 'curve analysis extraction' and 'speed limits database creation' are also part of our contribution. An algorithm that analyzes GPS information off-line identifies high curvature segments and estimates the speed for each curve. The speed limit database contains information about the different speed limit zones for each traveled path. Our DSA senses speed limits and curves of the road using GPS information and ensures smooth speed transitions between current and ideal speeds. Through experimental simulations with different control algorithms on real and simulated datasets, we prove that our method is able to significantly reduce lateral errors on sharp curves, to respect speed limits and consequently increase safety and comfort for the passenger.

  10. An algorithm of discovering signatures from DNA databases on a computer cluster.

    PubMed

    Lee, Hsiao Ping; Sheu, Tzu-Fang

    2014-10-05

    Signatures are short sequences that are unique and not similar to any other sequence in a database that can be used as the basis to identify different species. Even though several signature discovery algorithms have been proposed in the past, these algorithms require the entirety of databases to be loaded in the memory, thus restricting the amount of data that they can process. It makes those algorithms unable to process databases with large amounts of data. Also, those algorithms use sequential models and have slower discovery speeds, meaning that the efficiency can be improved. In this research, we are debuting the utilization of a divide-and-conquer strategy in signature discovery and have proposed a parallel signature discovery algorithm on a computer cluster. The algorithm applies the divide-and-conquer strategy to solve the problem posed to the existing algorithms where they are unable to process large databases and uses a parallel computing mechanism to effectively improve the efficiency of signature discovery. Even when run with just the memory of regular personal computers, the algorithm can still process large databases such as the human whole-genome EST database which were previously unable to be processed by the existing algorithms. The algorithm proposed in this research is not limited by the amount of usable memory and can rapidly find signatures in large databases, making it useful in applications such as Next Generation Sequencing and other large database analysis and processing. The implementation of the proposed algorithm is available at http://www.cs.pu.edu.tw/~fang/DDCSDPrograms/DDCSD.htm.

  11. AdaBoost-based on-line signature verifier

    NASA Astrophysics Data System (ADS)

    Hongo, Yasunori; Muramatsu, Daigo; Matsumoto, Takashi

    2005-03-01

    Authentication of individuals is rapidly becoming an important issue. The authors previously proposed a Pen-input online signature verification algorithm. The algorithm considers a writer"s signature as a trajectory of pen position, pen pressure, pen azimuth, and pen altitude that evolve over time, so that it is dynamic and biometric. Many algorithms have been proposed and reported to achieve accuracy for on-line signature verification, but setting the threshold value for these algorithms is a problem. In this paper, we introduce a user-generic model generated by AdaBoost, which resolves this problem. When user- specific models (one model for each user) are used for signature verification problems, we need to generate the models using only genuine signatures. Forged signatures are not available because imposters do not give forged signatures for training in advance. However, we can make use of another's forged signature in addition to the genuine signatures for learning by introducing a user generic model. And Adaboost is a well-known classification algorithm, making final decisions depending on the sign of the output value. Therefore, it is not necessary to set the threshold value. A preliminary experiment is performed on a database consisting of data from 50 individuals. This set consists of western-alphabet-based signatures provide by a European research group. In this experiment, our algorithm gives an FRR of 1.88% and an FAR of 1.60%. Since no fine-tuning was done, this preliminary result looks very promising.

  12. IgG Donor-Specific Anti-Human HLA Antibody Subclasses and Kidney Allograft Antibody-Mediated Injury.

    PubMed

    Lefaucheur, Carmen; Viglietti, Denis; Bentlejewski, Carol; Duong van Huyen, Jean-Paul; Vernerey, Dewi; Aubert, Olivier; Verine, Jérôme; Jouven, Xavier; Legendre, Christophe; Glotz, Denis; Loupy, Alexandre; Zeevi, Adriana

    2016-01-01

    Antibodies may have different pathogenicities according to IgG subclass. We investigated the association between IgG subclasses of circulating anti-human HLA antibodies and antibody-mediated kidney allograft injury. Among 635 consecutive kidney transplantations performed between 2008 and 2010, we enrolled 125 patients with donor-specific anti-human HLA antibodies (DSA) detected in the first year post-transplant. We assessed DSA characteristics, including specificity, HLA class specificity, mean fluorescence intensity (MFI), C1q-binding, and IgG subclass, and graft injury phenotype at the time of sera evaluation. Overall, 51 (40.8%) patients had acute antibody-mediated rejection (aABMR), 36 (28.8%) patients had subclinical ABMR (sABMR), and 38 (30.4%) patients were ABMR-free. The MFI of the immunodominant DSA (iDSA, the DSA with the highest MFI level) was 6724±464, and 41.6% of patients had iDSA showing C1q positivity. The distribution of iDSA IgG1-4 subclasses among the population was 75.2%, 44.0%, 28.0%, and 26.4%, respectively. An unsupervised principal component analysis integrating iDSA IgG subclasses revealed aABMR was mainly driven by IgG3 iDSA, whereas sABMR was driven by IgG4 iDSA. IgG3 iDSA was associated with a shorter time to rejection (P<0.001), increased microcirculation injury (P=0.002), and C4d capillary deposition (P<0.001). IgG4 iDSA was associated with later allograft injury with increased allograft glomerulopathy and interstitial fibrosis/tubular atrophy lesions (P<0.001 for all comparisons). Integrating iDSA HLA class specificity, MFI level, C1q-binding status, and IgG subclasses in a Cox survival model revealed IgG3 iDSA and C1q-binding iDSA were strongly and independently associated with allograft failure. These results suggest IgG iDSA subclasses identify distinct phenotypes of kidney allograft antibody-mediated injury. Copyright © 2016 by the American Society of Nephrology.

  13. DSA patterning options for logics and memory applications

    NASA Astrophysics Data System (ADS)

    Liu, Chi-Chun; Franke, Elliott; Mignot, Yann; LeFevre, Scott; Sieg, Stuart; Chi, Cheng; Meli, Luciana; Parnell, Doni; Schmidt, Kristin; Sanchez, Martha; Singh, Lovejeet; Furukawa, Tsuyoshi; Seshadri, Indira; De Silva, Ekmini Anuja; Tsai, Hsinyu; Lai, Kafai; Truong, Hoa; Farrell, Richard; Bruce, Robert; Somervell, Mark; Sanders, Daniel; Felix, Nelson; Arnold, John; Hetzer, David; Ko, Akiteru; Metz, Andrew; Colburn, Matthew; Corliss, Daniel

    2017-03-01

    The progress of three potential DSA applications, i.e. fin formation, via shrink, and pillars, were reviewed in this paper. For fin application, in addition to pattern quality, other important considerations such as customization and design flexibility were discussed. An electrical viachain study verified the DSA rectification effect on CD distribution by showing a tighter current distribution compared to that derived from the guiding pattern direct transfer without using DSA. Finally, a structural demonstration of pillar formation highlights the importance of pattern transfer in retaining both the CD and local CDU improvement from DSA. The learning from these three case studies can provide perspectives that may not have been considered thoroughly in the past. By including more important elements during DSA process development, the DSA maturity can be further advanced and move DSA closer to HVM adoption.

  14. Design strategy for integrating DSA via patterning in sub-7 nm interconnects

    NASA Astrophysics Data System (ADS)

    Karageorgos, Ioannis; Ryckaert, Julien; Tung, Maryann C.; Wong, H.-S. P.; Gronheid, Roel; Bekaert, Joost; Karageorgos, Evangelos; Croes, Kris; Vandenberghe, Geert; Stucchi, Michele; Dehaene, Wim

    2016-03-01

    In recent years, major advancements have been made in the directed self-assembly (DSA) of block copolymers (BCPs). As a result, the insertion of DSA for IC fabrication is being actively considered for the sub-7nm nodes. At these nodes the DSA technology could alleviate costs for multiple patterning and limit the number of litho masks that would be required per metal layer. One of the most straightforward approaches for DSA implementation would be for via patterning through templated DSA, where hole patterns are readily accessible through templated confinement of cylindrical phase BCP materials. Our in-house studies show that decomposition of via layers in realistic circuits below the 7nm node would require at least many multi-patterning steps (or colors), using 193nm immersion lithography. Even the use of EUV might require double patterning in these dimensions, since the minimum via distance would be smaller than EUV resolution. The grouping of vias through templated DSA can resolve local conflicts in high density areas. This way, the number of required colors can be significantly reduced. For the implementation of this approach, a DSA-aware mask decomposition is required. In this paper, our design approach for DSA via patterning in sub-7nm nodes is discussed. We propose options to expand the list of DSA-compatible via patterns (DSA letters) and we define matching cost formulas for the optimal DSA-aware layout decomposition. The flowchart of our proposed approach tool is presented.

  15. The Modular Clock Algorithm for Blind Rendezvous

    DTIC Science & Technology

    2009-03-26

    and Computer Engineering Graduate School of Engineering and Management Air Force Institute of Technology Air University Air Education and Training...capabilities in spectrum management and particularly in harvesting unused portions of pre-allocated band- width under DSA. The term “cognitive radio” was...of rendezvous and our role as the waiter . However, if the “child” refuses to move from non-common spectrum, rendezvous cannot occur. Bluetooth

  16. Influence of preformed donor-specific antibodies and C4d on early liver allograft function.

    PubMed

    Perera, M T; Silva, M A; Murphy, N; Briggs, D; Mirza, D F; Neil, D A H

    2013-12-01

    INTRODUCTION. The impact of preformed donor-specific antibodies (DSA) is incompletely understood in liver transplantation. The incidence and impact of preformed DSA on early post liver transplant were assessed and these were correlated with compliment fragment C4d on allograft biopsy. METHODS. Pretransplant serum from 41 consecutive liver transplant recipients (brain dead donors; DBD = 27 and cardiac death donors; DCD = 14) were tested for class-specific anti-human leukocyte antigen (HLA) and compared against donor HLA types. Liver biopsies were taken during cold storage (t-1) and post-reperfusion (t0) stained with C4d and graded for preservation-reperfusion injury (PRI). RESULTS. Of the 41 recipients, 8 (20%) had anti-HLA class I/II antibodies pretransplant, 3 (7%) were confirmed preformed DSA; classes I and II (n=1) and class I only (n=2). No biopsies showed definite evidence of antibody-mediated rejection. Graft biopsies in overall showed only mild PRI with ischemic hepatocyte C4d pattern similar in both positive and negative DSA patients. One DSA-positive (33%) compared with four DSA-negative patients (10%) had significant early graft dysfunction; severe PRI causing graft loss from primary nonfunction was seen only in DSA-negative group. Allograft biopsy of preformed DSA-positive patient demonstrated only minimal PRI; however, no identifiable cause could be attributed to graft dysfunction other than preformed DSA. CONCLUSION. Preformed DSA are present in 5-10% liver transplant recipients. There is no association between anti-HLA DSA and PRI and C4d, but preformed DSA may cause early morbidity. Larger studies on the impact of DSA with optimization of C4d techniques are required.

  17. Pre-transplant soluble CD30 in combination with total DSA but not pre-transplant C1q-DSA predicts antibody-mediated graft loss in presensitized high-risk kidney transplant recipients.

    PubMed

    Schaefer, S M; Süsal, C; Opelz, G; Döhler, B; Becker, L E; Klein, K; Sickmüller, S; Waldherr, R; Macher-Goeppinger, S; Schemmer, P; Beimler, J; Zeier, M; Morath, C

    2016-02-01

    Presensitized kidney transplant recipients are at high-risk for early antibody-mediated rejection. We studied the impact of pre- and post-transplant donor-specific human leukocyte antigen (HLA) antibodies (DSA) and T-cell-activation on the occurrence of antibody-mediated rejection episodes (AMR) and graft loss (AMR-GL) in a unique cohort of 80 desensitized high-risk kidney transplant recipients. Patients with pre-transplant DSA demonstrated more AMR episodes than patients without DSA, but did not show a significantly increased rate of AMR-GL. The rates of AMR and AMR-GL were not significantly increased in patients with complement split product (C1q)-binding pre-transplant DSA. Pre-transplant C1q-DSA became undetectable post-transplant in 11 of 13 (85%) patients; 2 (18%) of these 11 patients showed AMR but no AMR-GL. In contrast, the post-transplant presence of C1q-DSA was associated with significantly higher rates of AMR (86 vs 33 vs 0%; P < 0.001) and AMR-GL (86 vs 0 vs 0%; log-rank P < 0.001) compared with post-transplant DSA without C1q-binding or the absence of DSA. Patients with both pre-transplant DSA and evidence of pre-transplant T-cell-activation as indicated by soluble CD30-positivity showed a significantly increased risk for AMR-GL [HR = 11.1, 95% confidence interval (CI) = 1.68-73.4; log-rank P = 0.013]. In these high-risk patients, AMR-GL was associated with total DSA in combination with T-cell-activation pre-transplant, and de novo or persistent C1q-binding DSA post-transplant. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Electrical study of DSA shrink process and CD rectification effect at sub-60nm using EUV test vehicle

    NASA Astrophysics Data System (ADS)

    Chi, Cheng; Liu, Chi-Chun; Meli, Luciana; Guo, Jing; Parnell, Doni; Mignot, Yann; Schmidt, Kristin; Sanchez, Martha; Farrell, Richard; Singh, Lovejeet; Furukawa, Tsuyoshi; Lai, Kafai; Xu, Yongan; Sanders, Daniel; Hetzer, David; Metz, Andrew; Burns, Sean; Felix, Nelson; Arnold, John; Corliss, Daniel

    2017-03-01

    In this study, the integrity and the benefits of the DSA shrink process were verified through a via-chain test structure, which was fabricated by either DSA or baseline litho/etch process for via layer formation while metal layer processes remain the same. The nearest distance between the vias in this test structure is below 60nm, therefore, the following process components were included: 1) lamella-forming BCP for forming self-aligned via (SAV), 2) EUV printed guiding pattern, and 3) PS-philic sidewall. The local CDU (LCDU) of minor axis was improved by 30% after DSA shrink process. We compared two DSA Via shrink processes and a DSA_Control process, in which guiding patterns (GP) were directly transferred to the bottom OPL without DSA shrink. The DSA_Control apparently resulted in larger CD, thus, showed much higher open current and shorted the dense via chains. The non-optimized DSA shrink process showed much broader current distribution than the improved DSA shrink process, which we attributed to distortion and dislocation of the vias and ineffective SAV. Furthermore, preliminary defectivity study of our latest DSA process showed that the primary defect mode is likely to be etch-related. The challenges, strategies applied to improve local CD uniformity and electrical current distribution, and potential adjustments were also discussed.

  19. Conventional digital subtractional vs non-invasive MR angiography in the assessment of brain arteriovenous malformation.

    PubMed

    Cuong, Nguyen Ngoc; Luu, Vu Dang; Tuan, Tran Anh; Linh, Le Tuan; Hung, Kieu Dinh; Ngoc, Vo Truong Nhu; Sharma, Kulbhushan; Pham, Van Huy; Chu, Dinh-Toi

    2018-06-01

    Digital subtractional angiography (DSA) is the standard method for diagnosis, assessment and management of arteriovenous malformation in the brain. Conventional DSA (cDSA) is an invasive imaging modality that is often indicated before interventional treatments (embolization, open surgery, gamma knife). Here, we aimed to compare this technique with a non-invasive MR angiography (MRI DSA) for brain arteriovenous malformation (bAVM). Fourteen patients with ruptured brain AVM underwent embolization treatment pre-operation. Imaging was performed for all patients using MRI (1.5 T). After injecting contrast Gadolinium, dynamic MRI was performed with 40 phases, each phase of a duration of 1.2 s and having 70 images. The MRI results were independently assessed by experienced radiologist blinded to the cDSA. The AVM nidus was depicted in all patients using cDSA and MRI DSA; there was an excellent correlation between these techniques in terms of the maximum diameter and Spetzler Martin grading. Of the fourteen patients, the drainage vein was depicted in 13 by both cDSA and MRI DSA showing excellent correlation between the techniques used. MRI DSA is a non-invasive imaging modality that can give the images in dynamic view. It can be considered as an adjunctive method with cDSA to plan the strategy treatment for bAVM. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. The possible critical role of T-cell help in DSA-mediated graft loss.

    PubMed

    Süsal, Caner; Slavcev, Antonij; Pham, Lien; Zeier, Martin; Morath, Christian

    2018-06-01

    In this review, we discuss a possible central role of T-cell help in severe forms of graft damage mediated by donor-specific HLA antibodies (DSA). Some kidney transplant recipients with pretransplant DSA show a high graft failure rate, whereas in other patients DSA do not harm the transplanted kidney and in most cases, disappear shortly after transplantation. Analyzing 80 desensitized highly immunized kidney transplant recipients and another multicenter cohort of 385 patients with pretransplant HLA antibodies, we reported recently that an ongoing T-cell help from an activated immune system, as measured by an increased level of soluble CD30 in serum, might be necessary for the DSA to exert a deleterious effect. Patients positive for both pretransplant DSA and sCD30 appear to require special measures, such as the elimination of DSA from the circulation, potent immunosuppression, good HLA-matching, and intense post-transplant monitoring, whereas exclusion of DSA-positive patients from transplantation in the absence of high sCD30 may not be justified in all cases, even if the pretransplant DSA are strong and complement-activating. © 2018 Steunstichting ESOT.

  1. Revisiting Traditional Risk Factors for Rejection and Graft Loss after Kidney Transplantation

    PubMed Central

    Dunn, TB; Noreen, H; Gillingham, K; Maurer, D; Ozturk, O. Goruroglu; Pruett, TL; Bray, RA; Gebel, HM; Matas, AJ

    2011-01-01

    Single antigen bead (SAB) testing permits reassessment of immunologic risk for kidney transplantation. Traditionally, high panel reactive antibody (PRA), retransplant and deceased donor (DD) grafts have been associated with increased risk. We hypothesized that this risk was likely mediated by (unrecognized) donor-specific antibody (DSA). We grouped 587 kidney transplants using clinical history and SAB testing of day of transplant serum as 1) unsensitized; PRA=0 (n= 178), 2) 3rd party sensitized; no DSA (n=363), or 3) donor sensitized; with DSA (n=46), and studied rejection rates, death censored graft survival (DCGS), and risk factors for rejection. Antibody-mediated rejection (AMR) rates were increased with DSA (p<0.0001), but not with PRA in the absence of DSA. Cell-mediated rejection (CMR) rates were increased with DSA (p<0.005); with a trend to increased rates when PRA>0 in the absence of DSA (p=0.08). Multivariate analyses showed risk factors for AMR were DSA, worse HLA matching, and female gender; for CMR: DSA, PRA>0 and worse HLA matching. AMR and CMR were associated with decreased DCGS. The presence of DSA is an important predictor of rejection risk, in contrast to traditional risk factors. Further development of immunosuppressive protocols will be facilitated by stratification of rejection risk by donor sensitization. PMID:21812918

  2. Combinational Circuit Obfuscation Through Power Signature Manipulation

    DTIC Science & Technology

    2011-06-01

    Algorithm produced by SID . . . . . . . . . . . . . . . . . . . . . . 80 Appendix B . Power Signature Estimation Results 2 . . . . . . . . . . 85 B .1 Power...Signature for c264 Circuit Variant per Algorithm produced by SPICE Simulation . . . . . . . . . . . . . . 85 B .2 Power Signature for c5355 and c499...Smart SSR selecting rear level components and gates with 1000 iterations . . . . . . . . . 84 B .1. Power Signature for c264 By Random Sequence

  3. Donor Specific Anti-HLA Antibodies with Antibody Mediated Rejection and Long-term Outcomes Following Heart Transplantation

    PubMed Central

    Clerkin, Kevin J.; Farr, Maryjane A.; Restaino, Susan W.; Zorn, Emmanuel; Latif, Farhana; Vasilescu, Elena R.; Marboe, Charles C.; Colombo, Paolo C.; Mancini, Donna M.

    2017-01-01

    Introduction Donor specific anti-HLA antibodies (DSA) are common following heart transplantation and are associated with rejection, cardiac allograft vasculopathy (CAV), and mortality. Currently a non-invasive diagnostic test for pathologic AMR (pAMR) does not exist. Methods 221 consecutive adult patients underwent heart transplantation from January 1st, 2010 through August 31th, 2013 and followed through October 1st, 2015. The primary objective was to determine whether the presence of DSA could detect AMR at the time of pathologic diagnosis. Secondary analyses included the association of DSA (stratified by MHC Class and de-novo status) during AMR with new graft dysfunction, graft loss (mortality or retransplantation), and development of CAV. Results During the study period 69 individual patients (31.2%) had DSA (24% had de-novo DSA) and there were 74 episodes of pAMR in 38 unique patients. The sensitivity of DSA at any MFI to detect concurrent pAMR was only 54.3%. The presence of any DSA during pAMR increased the odds of graft dysfunction (OR 5.37, 95% CI 1.34–21.47, p=0.018), adjusting for age, gender, and timing of AMR. Circulating Class II DSA after transplantation increased the risk of future pAMR (HR 2.97, 95% CI 1.31–6.73, p=0.009). Patients who developed de-novo Class II DSA had a 151% increase in risk of graft loss (contingent on 30-day survival) compared with those who did not have DSA (95% CI 1.11–5.69, p=0.027). Conclusions DSA were inadequate to diagnose pAMR, but Class II DSA provided prognostic information regarding future pAMR, graft dysfunction with pAMR, and graft loss. PMID:27916323

  4. Donor-specific anti-HLA antibodies with antibody-mediated rejection and long-term outcomes following heart transplantation.

    PubMed

    Clerkin, Kevin J; Farr, Maryjane A; Restaino, Susan W; Zorn, Emmanuel; Latif, Farhana; Vasilescu, Elena R; Marboe, Charles C; Colombo, Paolo C; Mancini, Donna M

    2017-05-01

    Donor-specific anti-HLA antibodies (DSA) are common after heart transplantation and are associated with rejection, cardiac allograft vasculopathy, and mortality. A noninvasive diagnostic test for pathologic antibody-mediated rejection (pAMR) does not exist. From January 1, 2010, through August 31, 2013, 221 consecutive adult patients underwent heart transplantation and were followed through October 1, 2015. The primary objective was to determine whether the presence of DSA could detect AMR at the time of pathologic diagnosis. Secondary analyses included association of DSA (stratified by major histocompatibility complex class and de novo status) during AMR with new graft dysfunction, graft loss (mortality or retransplantation), and development of cardiac allograft vasculopathy. During the study period, 69 patients (31.2%) had DSA (24% had de novo DSA), and there were 74 episodes of pAMR in 38 patients. Sensitivity of DSA at any mean fluorescence intensity to detect concurrent pAMR was only 54.3%. The presence of any DSA during pAMR increased the odds of graft dysfunction (odds ratio = 5.37; 95% confidence interval [CI], 1.34-21.47; p = 0.018), adjusting for age, sex, and timing of AMR. Circulating class II DSA after transplantation increased risk of future pAMR (hazard ratio = 2.97; 95% CI, 1.31-6.73; p = 0.009). Patients who developed de novo class II DSA had 151% increased risk of graft loss (contingent on 30-day survival) compared with patients who did not have DSA (95% CI, 1.11-5.69; p = 0.027). DSA were inadequate to diagnose pAMR. Class II DSA provided prognostic information regarding future pAMR, graft dysfunction with pAMR, and graft loss. Copyright © 2017 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  5. Donor-specific HLA alloantibodies: Impact on cardiac allograft vasculopathy, rejection, and survival after pediatric heart transplantation.

    PubMed

    Tran, Andrew; Fixler, David; Huang, Rong; Meza, Tiffany; Lacelle, Chantale; Das, Bibhuti B

    2016-01-01

    There is increasing evidence that donor-specific anti-HLA antibodies (DSA) are associated with poor outcomes after cardiac transplantation in adults, but data are limited in children. The objective of this study was to examine the development and consequences of de novo DSA in pediatric recipients of heart transplants. We analyzed 105 pediatric patients who received heart transplants at our center from January 2002 to December 2012. All patients had negative T-cell and B-cell post-transplant crossmatches. Patients underwent HLA antibody screening at 1, 2, 3, 6, and 12 months post-transplant and annually thereafter unless there was suspicion for rejection. HLA class I and II antibodies were identified using Luminex assay. Coronary angiography was performed at 1 year and annually thereafter. Acute cellular rejection, antibody-mediated rejection, and treated clinical rejections were included together as rejection events. Of 105 patients, 45 (43%) developed de novo DSA. DSA-positive patients had significantly higher rates of coronary artery vasculopathy (CAV) compared with DSA-negative patients (36% vs 13%). CAV-free survival at 1 year and 5 years post-transplant for DSA-negative patients was 90% and 25%, respectively, compared with 70% and 0%, respectively, for DSA-positive patients (p < 0.01). DSA-positive patients had 2.5 times more rejection events per year than DSA-negative patients. The 5-year graft survival rate was 72.4% for DSA-negative patients and 21% for DSA-positive patients (p < 0.001). De novo DSA has a strong negative impact on CAV, rejection, and graft survival in pediatric recipients of heart transplants. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  6. Distributed Spectral Monitoring For Emitter Localization

    DTIC Science & Technology

    2018-02-12

    localization techniques in a DSA sensor network. The results of the research are presented through simulation of localization algorithms, emulation of a...network on a wireless RF environment emulator, and field tests. The results of the various tests in both the lab and field are obtained and analyzed to... are two main classes of localization techniques, and the technique to use will depend on the information available with the emitter. The first class

  7. Dynamic Speed Adaptation for Path Tracking Based on Curvature Information and Speed Limits †

    PubMed Central

    Gámez Serna, Citlalli; Ruichek, Yassine

    2017-01-01

    A critical concern of autonomous vehicles is safety. Different approaches have tried to enhance driving safety to reduce the number of fatal crashes and severe injuries. As an example, Intelligent Speed Adaptation (ISA) systems warn the driver when the vehicle exceeds the recommended speed limit. However, these systems only take into account fixed speed limits without considering factors like road geometry. In this paper, we consider road curvature with speed limits to automatically adjust vehicle’s speed with the ideal one through our proposed Dynamic Speed Adaptation (DSA) method. Furthermore, ‘curve analysis extraction’ and ‘speed limits database creation’ are also part of our contribution. An algorithm that analyzes GPS information off-line identifies high curvature segments and estimates the speed for each curve. The speed limit database contains information about the different speed limit zones for each traveled path. Our DSA senses speed limits and curves of the road using GPS information and ensures smooth speed transitions between current and ideal speeds. Through experimental simulations with different control algorithms on real and simulated datasets, we prove that our method is able to significantly reduce lateral errors on sharp curves, to respect speed limits and consequently increase safety and comfort for the passenger. PMID:28613251

  8. Implementation of Digital Signature Using Aes and Rsa Algorithms as a Security in Disposition System af Letter

    NASA Astrophysics Data System (ADS)

    Siregar, H.; Junaeti, E.; Hayatno, T.

    2017-03-01

    Activities correspondence is often used by agencies or companies, so that institutions or companies set up a special division to handle issues related to the letter management. Most of the distribution of letters using electronic media, then the letter should be kept confidential in order to avoid things that are not desirable. Techniques that can be done to meet the security aspect is by using cryptography or by giving a digital signature. The addition of asymmetric and symmetric algorithms, i.e. RSA and AES algorithms, on the digital signature had been done in this study to maintain data security. The RSA algorithm was used during the process of giving digital signature, while the AES algorithm was used during the process of encoding a message that will be sent to the receiver. Based on the research can be concluded that the additions of AES and RSA algorithms on the digital signature meet four objectives of cryptography: Secrecy, Data Integrity, Authentication and Non-repudiation.

  9. Balloon-Occluded Carbon Dioxide Gas Angiography for Internal Iliac Arteriography and Intervention.

    PubMed

    Kishino, Mitsuhiro; Nakaminato, Shuichiro; Kitazume, Yoshio; Miyasaka, Naoyuki; Kudo, Toshifumi; Saida, Yukihisa; Tateishi, Ukihide

    2018-07-01

    The usefulness of carbon dioxide (CO 2 ) gas digital subtraction angiography (DSA) has been reported for patients with renal insufficiency and allergy to iodinated contrast agents. However, CO 2 gas cannot replace the iodinated contrast agent in all cases owing to some disadvantages. We describe balloon-occluded CO 2 DSA (B-CO 2 DSA) as an improved CO 2 DSA procedure for interventions in the internal iliac artery (IIA) region and compare the quality of images obtained using conventional CO 2 DSA and B-CO 2 DSA. B-CO 2 DSA-guided embolization was performed for one case of genital bleeding with an acute anaphylactic reaction to the iodinated contrast agent and for three cases of type II endoleaks after endovascular abdominal aortic aneurysm repair with renal dysfunction. A 9-mm occlusion balloon catheter was placed just after the orifice of the IIA. Then, 10-15 ml of CO 2 gas was injected manually via the catheter with and without balloon occlusion. The quality of sequential digital subtraction angiograms was analyzed based on a scoring criterion. In all four cases, image quality was improved with B-CO 2 DSA; the poor quality of images without balloon occlusion was because of reflux of the CO 2 gas. B-CO 2 DSA improves the image quality of CO 2 DSA in the IIA region and is useful for vascular intervention. Level IV.

  10. Prospective Monitoring of Donor-specific Anti-HLA Antibodies After Intestine/Multivisceral Transplantation: Significance of De Novo Antibodies.

    PubMed

    Kubal, Chandrashekhar; Mangus, Richard; Saxena, Romil; Lobashevsky, Andrew; Higgins, Nancy; Fridell, Jonathan; Tector, A Joseph

    2015-08-01

    Presence of circulating donor-specific antibodies (DSA) may be associated with worse clinical outcomes after intestine/multivisceral transplantation. In 79 intestine/multivisceral recipients, sera were prospectively screened for DSA by Luminex Single antigen test at 1, 3, 6, 9, 12, 18, 24, and 36 months after transplantation. Standard immunosuppression included thymoglobulin-rituximab induction and tacrolimus-prednisone maintenance. C4d staining was performed retrospectively on biopsies in patients that developed acute rejection (AR). Twenty-two (28%) patients developed de novo DSA at a median posttransplant period of 3 (1-36) months. De novo DSA were observed in 10 of 40 liver-including and 12 of 39 liver-excluding transplants (P = 0.57). Occurrence of AR was slightly higher in patients with de novo DSA (45% vs 33%, respectively; P = 0.41). Similarly, chronic rejection (14% vs 5%; P = 0.21) and graft loss due to AR (18% vs 7%; P = 0.14) were numerically higher in patients with de novo DSA. Only 35% patients experiencing AR had circulating de novo DSA at the time of AR. Antibody-mediated rejection was diagnosed in 6 patients based on C4d staining, of these 2 patients had circulating de novo DSA at the time of biopsy. De novo DSA formation, particularly early in the posttransplant course may be associated with trends toward worse outcomes. However, its significance in the pathophysiology of AR remains uncertain. Studies focusing mechanisms of DSA-related graft injury and intragraft DSA detection might provide further insight into this issue.

  11. Secure and Efficient Signature Scheme Based on NTRU for Mobile Payment

    NASA Astrophysics Data System (ADS)

    Xia, Yunhao; You, Lirong; Sun, Zhe; Sun, Zhixin

    2017-10-01

    Mobile payment becomes more and more popular, however the traditional public-key encryption algorithm has higher requirements for hardware which is not suitable for mobile terminals of limited computing resources. In addition, these public-key encryption algorithms do not have the ability of anti-quantum computing. This paper researches public-key encryption algorithm NTRU for quantum computation through analyzing the influence of parameter q and k on the probability of generating reasonable signature value. Two methods are proposed to improve the probability of generating reasonable signature value. Firstly, increase the value of parameter q. Secondly, add the authentication condition that meet the reasonable signature requirements during the signature phase. Experimental results show that the proposed signature scheme can realize the zero leakage of the private key information of the signature value, and increase the probability of generating the reasonable signature value. It also improve rate of the signature, and avoid the invalid signature propagation in the network, but the scheme for parameter selection has certain restrictions.

  12. U.S. Army Research Laboratory (ARL) multimodal signatures database

    NASA Astrophysics Data System (ADS)

    Bennett, Kelly

    2008-04-01

    The U.S. Army Research Laboratory (ARL) Multimodal Signatures Database (MMSDB) is a centralized collection of sensor data of various modalities that are co-located and co-registered. The signatures include ground and air vehicles, personnel, mortar, artillery, small arms gunfire from potential sniper weapons, explosives, and many other high value targets. This data is made available to Department of Defense (DoD) and DoD contractors, Intel agencies, other government agencies (OGA), and academia for use in developing target detection, tracking, and classification algorithms and systems to protect our Soldiers. A platform independent Web interface disseminates the signatures to researchers and engineers within the scientific community. Hierarchical Data Format 5 (HDF5) signature models provide an excellent solution for the sharing of complex multimodal signature data for algorithmic development and database requirements. Many open source tools for viewing and plotting HDF5 signatures are available over the Web. Seamless integration of HDF5 signatures is possible in both proprietary computational environments, such as MATLAB, and Free and Open Source Software (FOSS) computational environments, such as Octave and Python, for performing signal processing, analysis, and algorithm development. Future developments include extending the Web interface into a portal system for accessing ARL algorithms and signatures, High Performance Computing (HPC) resources, and integrating existing database and signature architectures into sensor networking environments.

  13. Revisiting traditional risk factors for rejection and graft loss after kidney transplantation.

    PubMed

    Dunn, T B; Noreen, H; Gillingham, K; Maurer, D; Ozturk, O G; Pruett, T L; Bray, R A; Gebel, H M; Matas, A J

    2011-10-01

    Single-antigen bead (SAB) testing permits reassessment of immunologic risk for kidney transplantation. Traditionally, high panel reactive antibody (PRA), retransplant and deceased donor (DD) grafts have been associated with increased risk. We hypothesized that this risk was likely mediated by (unrecognized) donor-specific antibody (DSA). We grouped 587 kidney transplants using clinical history and single-antigen bead (SAB) testing of day of transplant serum as (1) unsensitized; PRA = 0 (n = 178), (2) third-party sensitized; no DSA (n = 363) or (3) donor sensitized; with DSA (n = 46), and studied rejection rates, death-censored graft survival (DCGS) and risk factors for rejection. Antibody-mediated rejection (AMR) rates were increased with DSA (p < 0.0001), but not with panel reactive antibody (PRA) in the absence of DSA. Cell-mediated rejection (CMR) rates were increased with DSA (p < 0.005); with a trend to increased rates when PRA>0 in the absence of DSA (p = 0.08). Multivariate analyses showed risk factors for AMR were DSA, worse HLA matching, and female gender; for CMR: DSA, PRA>0 and worse HLA matching. AMR and CMR were associated with decreased DCGS. The presence of DSA is an important predictor of rejection risk, in contrast to traditional risk factors. Further development of immunosuppressive protocols will be facilitated by stratification of rejection risk by donor sensitization. ©2011 The Authors Journal compilation©2011 The American Society of Transplantation and the American Society of Transplant Surgeons.

  14. Concordance of Time-of-Flight MRA and Digital Subtraction Angiography in Adult Primary Central Nervous System Vasculitis.

    PubMed

    de Boysson, H; Boulouis, G; Parienti, J-J; Touzé, E; Zuber, M; Arquizan, C; Dequatre, N; Detante, O; Bienvenu, B; Aouba, A; Guillevin, L; Pagnoux, C; Naggara, O

    2017-10-01

    3D-TOF-MRA and DSA are 2 available tools to demonstrate neurovascular involvement in primary central nervous system vasculitis. We aimed to compare the diagnostic concordance of vessel imaging using 3D-TOF-MRA and DSA in patients with primary central nervous system vasculitis. We retrospectively identified all patients included in the French primary central nervous system vasculitis cohort of 85 patients who underwent, at baseline, both intracranial 3D-TOF-MRA and DSA in an interval of no more than 2 weeks and before treatment initiation. Two neuroradiologists independently reviewed all 3D-TOF-MRA and DSA imaging. Brain vasculature was divided into 25 arterial segments. Concordance between 3D-TOF-MRA and DSA for the identification of arterial stenosis was assessed by the Cohen κ Index. Thirty-one patients met the inclusion criteria, including 20 imaged with a 1.5T MR unit and 11 with a 3T MR unit. Among the 25 patients (81%) with abnormal DSA findings, 24 demonstrated abnormal 3D-TOF-MRA findings, whereas all 6 remaining patients with normal DSA findings had normal 3D-TOF-MRA findings. In the per-segment analysis, concordance between 1.5T 3D-TOF-MRA and DSA was 0.82 (95% CI, 0.75-0.93), and between 3T 3D-TOF-MRA and DSA, it was 0.87 (95% CI, 0.78-0.91). 3D-TOF-MRA shows a high concordance with DSA in diagnostic performance when analyzing brain vasculature in patients with primary central nervous system vasculitis. In patients with negative 3T 3D-TOF-MRA findings, the added diagnostic value of DSA is limited. © 2017 by American Journal of Neuroradiology.

  15. Digital Subtraction Angiography or Computed Tomography Angiography in the Preoperative Evaluation of Lower Limb Peripheral Artery Disease - A Comparative Analysis.

    PubMed

    Dias-Neto, Marina; Marques, Catarina; Sampaio, Sérgio

    2017-01-01

    For several years, digital subtraction angiography (DSA) was considered the gold standard method for the evaluation of PAD patients. This is an invasive technique and allows a good evaluation of collaterals and the vessel lumen, even in cases with associated calcification. Nevertheless, recent technical development of computed tomography angiography (CTA) has improved its specificity and sensibility, besides the fact that CTA is a fast and non-invasive procedure. To characterize a cohort of lower limb PAD patients and clarify if there are differences among the patients preoperatively evaluated by DSA or CTA. This retrospective study focused on PAD patients with a Rutherford classification ≥ 3 and submitted to intervention (endovascular revascularization or open surgery). The CTA group included all patients submitted to this method as their preoperative exam, between March 2009 and April 2017. In the same period of time, patients submitted to DSA as their preoperative exam, were randomly selected. The exclusion criteria were: realization of the exam for a different diagnosis than PAD, amputation not preceded by revascularization, absence of intervention during a period of 1 year after the realization of the exam. The groups were compared upon the type of surgery (open vs endovascular), number of revascularization sectors, reintervention, amputation, mortality and length of hospital stay. 34 CTA patients and 71 DSA patients were included. The groups were demographically and clinically homogeneous. In what regards to arterial lesions, the DSA group showed more often lesions of the distal sector with TASC C or D classification (25% in DSA group and 0% in CTA group; p=0,001), as well as scarcity of runoff vessels (0 or 1 in 72% of DSA patients group and 26% in CTA group; p=0.001). There were no differences about the endovascular and open surgery ratio (1.8 to CTA and 1.4 to DSA; p=0.305), reintervention rates (21% CTA and 16% DSA; p=0.517), major amputation (9% CTA and 11% DSA; p=1), minor amputation (9% CTA and 16% DSA; p=0.541), mortality (18% CTA and 23% DSA; p=0,602), or length of hospital stay (median and (interquartile range) of 14 (27) for CTA and 14 (17) for DSA; p=0.933). CTA seems to be a method for morphological and therapeutic planning of PAD that is non-inferior to DSA.

  16. Signature Verification Based on Handwritten Text Recognition

    NASA Astrophysics Data System (ADS)

    Viriri, Serestina; Tapamo, Jules-R.

    Signatures continue to be an important biometric trait because it remains widely used primarily for authenticating the identity of human beings. This paper presents an efficient text-based directional signature recognition algorithm which verifies signatures, even when they are composed of special unconstrained cursive characters which are superimposed and embellished. This algorithm extends the character-based signature verification technique. The experiments carried out on the GPDS signature database and an additional database created from signatures captured using the ePadInk tablet, show that the approach is effective and efficient, with a positive verification rate of 94.95%.

  17. Graft Immunocomplex Capture Fluorescence Analysis to Detect Donor-Specific Antibodies and HLA Antigen Complexes in the Allograft.

    PubMed

    Nakamura, Tsukasa; Ushigome, Hidetaka; Watabe, Kiyoko; Imanishi, Yui; Masuda, Koji; Matsuyama, Takehisa; Harada, Shumpei; Koshino, Katsuhiro; Iida, Taku; Nobori, Shuji; Yoshimura, Norio

    2017-04-01

    Immunocomplex capture fluorescence analysis (ICFA) is an attractive method to detect donor-specific anti-HLA antibodies (DSA) and HLA antigen complexes. Currently, antibody-mediated rejection (AMR) due to DSA is usually diagnosed by C4d deposition and serological DSA detection. Conversely, there is a discrepancy between these findings frequently. Thereupon, our graft ICFA technique may contribute to establish the diagnosis of AMR. Graft samples were obtained by a percutaneous needle biopsy. Then, the specimen was dissolved in PBS by the lysis buffer. Subsequently, HLA antigens were captured by anti-HLA beads. Then, DSA-HLA complexes were detected by PE-conjugated anti-human IgG antibodies, where DSA had already reacted with the allograft in vivo, analyzed by a Luminex system. A ratio (sample MFI/blank beads MFI) was calculated: ≥ 1.0 was determined as positive. We found that DSA-HLA complexes in the graft were successfully detected from only slight positive 1.03 to 79.27 in a chronic active AMR patient by graft ICFA. Next, positive graft ICFA had predicted the early phase of AMR (MFI ratio: 1.38) even in patients with no serum DSA. Finally, appropriate therapies for AMR deleted DSA deposition (MFI ratio from 0.3 to 0.7) from allografts. This novel application would detect early phase or incomplete pathological cases of AMR, which could lead to a correct diagnosis and initiation of appropriate therapies. Moreover, graft ICFA might address a variety of long-standing questions in terms of DSA. AMR: Antibody-mediated rejection; DSA: Donor-specific antibodies; ICFA: Immunocomplex capture fluorescence analysis.

  18. Characteristics of Donor-Specific Antibodies Associated With Antibody-Mediated Rejection in Lung Transplantation

    PubMed Central

    Roux, Antoine; Bendib Le Lan, Ines; Holifanjaniaina, Sonia; Thomas, Kimberly A.; Picard, Clément; Grenet, Dominique; De Miranda, Sandra; Douvry, Benoit; Beaumont-Azuar, Laurence; Sage, Edouard; Devaquet, Jérôme; Cuquemelle, Elise; Le Guen, Morgan; Suberbielle, Caroline; Gautreau, Chantal; Stern, Marc; Rossetti, Maura; Hamid, Abdul Monem; Parquin, Francois

    2017-01-01

    Although donor-specific anti-human leukocyte antigen (HLA) antibodies (DSAs) are frequently found in recipients after lung transplantation (LT), the characteristics of DSA which influence antibody-mediated rejection (AMR) in LT are not fully defined. We retrospectively analyzed 206 consecutive LT patients of our center (2010–2013). DSAs were detected by using luminex single antigen beads assay and mean fluorescence intensity was assessed. Within the study population, 105 patients had positive DSA. Patients with and without AMR (AMRPos, n = 22, and AMRNeg, n = 83, respectively) were compared. AMRPos patients had significantly greater frequencies of anti-HLA DQ DSA (DQ DSA) than AMRNeg patients (95 vs 58%, respectively, p < 0.0001). Compared to AMRNeg patients, AMRPos patients had higher DQ DSA sum MFI [7,332 (2,067–10,213) vs 681 (0–1,887), p < 0.0001]. DQ DSA when associated with AMR, had more frequent graft loss and chronic lung allograft dysfunction (CLAD). These data suggest (i) that DSA characteristics clearly differ between AMRPos and AMRNeg patients and (ii) the deleterious impact of DQ DSA on clinical outcome. PMID:29075627

  19. The Maximum Likelihood Estimation of Signature Transformation /MLEST/ algorithm. [for affine transformation of crop inventory data

    NASA Technical Reports Server (NTRS)

    Thadani, S. G.

    1977-01-01

    The Maximum Likelihood Estimation of Signature Transformation (MLEST) algorithm is used to obtain maximum likelihood estimates (MLE) of affine transformation. The algorithm has been evaluated for three sets of data: simulated (training and recognition segment pairs), consecutive-day (data gathered from Landsat images), and geographical-extension (large-area crop inventory experiment) data sets. For each set, MLEST signature extension runs were made to determine MLE values and the affine-transformed training segment signatures were used to classify the recognition segments. The classification results were used to estimate wheat proportions at 0 and 1% threshold values.

  20. Arbitrated Quantum Signature with Hamiltonian Algorithm Based on Blind Quantum Computation

    NASA Astrophysics Data System (ADS)

    Shi, Ronghua; Ding, Wanting; Shi, Jinjing

    2018-03-01

    A novel arbitrated quantum signature (AQS) scheme is proposed motivated by the Hamiltonian algorithm (HA) and blind quantum computation (BQC). The generation and verification of signature algorithm is designed based on HA, which enables the scheme to rely less on computational complexity. It is unnecessary to recover original messages when verifying signatures since the blind quantum computation is applied, which can improve the simplicity and operability of our scheme. It is proved that the scheme can be deployed securely, and the extended AQS has some extensive applications in E-payment system, E-government, E-business, etc.

  1. Arbitrated Quantum Signature with Hamiltonian Algorithm Based on Blind Quantum Computation

    NASA Astrophysics Data System (ADS)

    Shi, Ronghua; Ding, Wanting; Shi, Jinjing

    2018-07-01

    A novel arbitrated quantum signature (AQS) scheme is proposed motivated by the Hamiltonian algorithm (HA) and blind quantum computation (BQC). The generation and verification of signature algorithm is designed based on HA, which enables the scheme to rely less on computational complexity. It is unnecessary to recover original messages when verifying signatures since the blind quantum computation is applied, which can improve the simplicity and operability of our scheme. It is proved that the scheme can be deployed securely, and the extended AQS has some extensive applications in E-payment system, E-government, E-business, etc.

  2. A Critical Analysis of the Utility of Intraoperative Angiography.

    PubMed

    Ares, William J; Kenmuir, Cynthia L; Panczykowski, David M; Weiner, Gregory M; Jadhav, Ashu P; Jovin, Tudor G; Gross, Bradley A; Jankowitz, Brian T

    2018-02-01

    Intraoperative digital subtraction angiography (ioDSA) is touted as the gold standard imaging evaluation for aneurysm clip constructs. Candid evaluations of its limitations are sparse. A prospectively collected hospital billing database was queried to identify craniotomies for aneurysm clipping from January 2010 to December 2013. We evaluated the rate of occult residual and parent vessel stenosis determined on follow-up angiography for patients undergoing ioDSA and those not undergoing ioDSA. Comparisons were performed via Fisher exact test, with P < 0.05 considered statistically significant. From our database search, we found 187 patients who underwent ioDSA after aneurysm clipping and an additional 91 patients who did not. Results from ioDSA influenced operative management in 17% of cases. Sixty-four patients with 70 treated aneurysms undergoing ioDSA had postoperative angiography; 7 occult residuals were discovered, yielding a 10% false-negative rate, with 10% of aneurysms showing residual. Occult residuals at the middle cerebral artery bifurcation represented most discovered residuals (6/7). Thirty-two patients with 37 treated aneurysms did not undergo ioDSA and had angiographic follow-up; 24% of patients were found to have residual aneurysms (P = 0.08 compared with patients undergoing ioDSA). Residuals at the anterior communicating artery (ACoA) represented 56% of all residuals, whereas the ACoA represented only 18% of aneurysms clipped. The rate of residuals was significantly higher than that for patients with clipped ACoA aneurysms undergoing ioDSA (P = 0.008). ioDSA influenced management in nearly one fifth of cases. It can be particularly beneficial in detecting residuals for ACoA aneurysms; its benefit was less apparent for middle cerebral artery aneurysms. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aoyama, Hidefumi; Shirato, Hiroki; Katoh, Norio

    Purpose: To investigate the discrepancy between the arteriovenous malformations seen on magnetic resonance angiography (MRA) and on stereotactic digital subtracted angiography (DSA). Methods and Materials: The target volume on stereotactic DSA (V{sub DSA} ) and the target volume on MRA (V{sub MRA} ) were separately delineated in 28 intracranial arteriovenous malformations. The coordinates of the center and the outer edges of V{sub DSA} and V{sub MRA} were calculated and used for the analyses. Results: The standard deviations (mean value) of the displacement of centers of V{sub MRA} from V{sub DSA} were 2.67 mm (-1.82 mm) in the left-right direction, 3.23more » mm (-0.08 mm) in the anterior-posterior direction, and 2.16 mm (0.91 mm) in the craniocaudal direction. V{sub MRA} covered less than 80% of V{sub DSA} in any dimensions in 9 cases (32%), although no significant difference was seen in the target volume between each method, with a mean value of 11.9 cc for V{sub DSA} and 12.3 cc for V{sub MRA} (p = 0.948). Conclusion: The shift of centers between each modality is not negligible. Considering no significant difference between V{sub DSA} and V{sub MRA} , but inadequate coverage of the V{sub DSA} by V{sub MRA} , it is reasonable to consider that the target on MRA might include the feeding artery and draining vein and possibly miss a portion of the nidus.« less

  4. Donor-specific antibodies require preactivated immune system to harm renal transplant.

    PubMed

    Süsal, Caner; Döhler, Bernd; Ruhenstroth, Andrea; Morath, Christian; Slavcev, Antonij; Fehr, Thomas; Wagner, Eric; Krüger, Bernd; Rees, Margaret; Balen, Sanja; Živčić-Ćosić, Stela; Norman, Douglas J; Kuypers, Dirk; Emonds, Marie-Paule; Pisarski, Przemyslaw; Bösmüller, Claudia; Weimer, Rolf; Mytilineos, Joannis; Scherer, Sabine; Tran, Thuong H; Gombos, Petra; Schemmer, Peter; Zeier, Martin; Opelz, Gerhard

    2016-07-01

    It is an unresolved issue why some kidney transplant recipients with pretransplant donor-specific HLA antibodies (DSA) show a high transplant failure rate, whereas in other patients DSA do not harm the graft. We investigated whether help from preactivated T-cells might be necessary for DSA to exert a deleterious effect. The impact of pretransplant DSA and immune activation marker soluble CD30 (sCD30) on 3-year graft survival was analyzed in 385 presensitized kidney transplant recipients. A deleterious influence of pretransplant DSA on graft survival was evident only in patients who were positive for the immune activation marker sCD30. In the absence of sCD30 positivity, 3-year graft survival was virtually identical in patients with or without DSA (83.1±3.9% and 84.3±2.8%, P=0.81). A strikingly lower 3-year graft survival rate of 62.1±6.4% was observed in patients who were both sCD30 and DSA positive (HR 2.92, P<0.001). Even in the presence of strong DSA with ≥5000 MFI, the 3-year graft survival rate was high if the recipients were sCD30 negative. Pretransplant DSA have a significantly deleterious impact on graft survival only in the presence of high pretransplant levels of the activation marker sCD30. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  5. Methods of extending crop signatures from one area to another

    NASA Technical Reports Server (NTRS)

    Minter, T. C. (Principal Investigator)

    1979-01-01

    Efforts to develop a technology for signature extension during LACIE phases 1 and 2 are described. A number of haze and Sun angle correction procedures were developed and tested. These included the ROOSTER and OSCAR cluster-matching algorithms and their modifications, the MLEST and UHMLE maximum likelihood estimation procedures, and the ATCOR procedure. All these algorithms were tested on simulated data and consecutive-day LANDSAT imagery. The ATCOR, OSCAR, and MLEST algorithms were also tested for their capability to geographically extend signatures using LANDSAT imagery.

  6. Coarse mesh and one-cell block inversion based diffusion synthetic acceleration

    NASA Astrophysics Data System (ADS)

    Kim, Kang-Seog

    DSA (Diffusion Synthetic Acceleration) has been developed to accelerate the SN transport iteration. We have developed solution techniques for the diffusion equations of FLBLD (Fully Lumped Bilinear Discontinuous), SCB (Simple Comer Balance) and UCB (Upstream Corner Balance) modified 4-step DSA in x-y geometry. Our first multi-level method includes a block Gauss-Seidel iteration for the discontinuous diffusion equation, uses the continuous diffusion equation derived from the asymptotic analysis, and avoids void cell calculation. We implemented this multi-level procedure and performed model problem calculations. The results showed that the FLBLD, SCB and UCB modified 4-step DSA schemes with this multi-level technique are unconditionally stable and rapidly convergent. We suggested a simplified multi-level technique for FLBLD, SCB and UCB modified 4-step DSA. This new procedure does not include iterations on the diffusion calculation or the residual calculation. Fourier analysis results showed that this new procedure was as rapidly convergent as conventional modified 4-step DSA. We developed new DSA procedures coupled with 1-CI (Cell Block Inversion) transport which can be easily parallelized. We showed that 1-CI based DSA schemes preceded by SI (Source Iteration) are efficient and rapidly convergent for LD (Linear Discontinuous) and LLD (Lumped Linear Discontinuous) in slab geometry and for BLD (Bilinear Discontinuous) and FLBLD in x-y geometry. For 1-CI based DSA without SI in slab geometry, the results showed that this procedure is very efficient and effective for all cases. We also showed that 1-CI based DSA in x-y geometry was not effective for thin mesh spacings, but is effective and rapidly convergent for intermediate and thick mesh spacings. We demonstrated that the diffusion equation discretized on a coarse mesh could be employed to accelerate the transport equation. Our results showed that coarse mesh DSA is unconditionally stable and is as rapidly convergent as fine mesh DSA in slab geometry. For x-y geometry our coarse mesh DSA is very effective for thin and intermediate mesh spacings independent of the scattering ratio, but is not effective for purely scattering problems and high aspect ratio zoning. However, if the scattering ratio is less than about 0.95, this procedure is very effective for all mesh spacing.

  7. Digital subtraction angiography of the pulmonary arteries for the diagnosis of pulmonary embolism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ludwig, J.W.; Verhoeven, L.A.J.; Kersbergen, J.J.

    1983-06-01

    A comparative study of radionuclide scanning (perfusion studies in all 18 patients and ventilation studies in 9) and digital subtraction angiography (DSA) was performed in 18 patients with suspected pulmonary thromboembolism. In 17 patients good visualization of the arteries was obtained with DSA; 10 of these patients had no pre-existing lung disease, and 7 had chronic obstructive pulmonary disease (COPD). The information provided by DSA in this small group was equal to or better than that of scintigraphy, especially in patients with COPD, and the reliability of DSA was superior to that of the radionuclide scintigraphy. Methods for preventing motionmore » artifacts with DSA are also described.« less

  8. Signature Verification Using N-tuple Learning Machine.

    PubMed

    Maneechot, Thanin; Kitjaidure, Yuttana

    2005-01-01

    This research presents new algorithm for signature verification using N-tuple learning machine. The features are taken from handwritten signature on Digital Tablet (On-line). This research develops recognition algorithm using four features extraction, namely horizontal and vertical pen tip position(x-y position), pen tip pressure, and pen altitude angles. Verification uses N-tuple technique with Gaussian thresholding.

  9. The myocutaneous trapezius flap revisited: a treatment algorithm for optimal surgical outcomes based on 43 flap reconstructions.

    PubMed

    Can, Anil; Orgill, Dennis P; Dietmar Ulrich, J O; Mureau, Marc A M

    2014-12-01

    Because the vascular anatomy of the trapezius flap is highly variable, choosing the most appropriate flap type and design is essential to optimize outcomes and minimize postoperative complications. The aim of this study was to develop a surgical treatment algorithm for trapezius flap transfers. The medical files of all consecutive patients with a myocutaneous trapezius flap reconstruction of the head, neck, and upper back area treated at three different university medical centers between July 2001 and November 2012 were reviewed. There were 43 consecutive flaps performed in 38 patients with a mean follow-up time of 15 months (range, 1-48 months). Eleven patients had a mentosternal burn scar contracture (12 flaps), 12 patients (13 flaps) presented with cancer, and 15 patients (18 flaps) were suffering from chronic wounds due to failed previous reconstruction (n = 6), osteoradionecrosis (n = 1), chronic infection (n = 3), bronchopleural fistula (n = 3), and pressure sores (n = 2). The mean defect size was 152 cm(2). Sixteen flaps were based on the superficial cervical artery (SCA; type 2), 16 were based on the dorsal scapular artery (DSA; type 3), one was based on the intercostal arteries (type 4), and 10 flaps were based on both the DSA and SCA. Recipient-site complications requiring reoperation occurred in 16.3%, including one total flap failure (2.6%). The trapezius myocutaneous flap is a valuable option to reconstruct various head and neck and upper back defects. Based on our data, a surgical treatment algorithm was developed in an attempt to reduce variation in care and improve clinical outcomes. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Deuterated scintillators and their application to neutron spectroscopy

    NASA Astrophysics Data System (ADS)

    Febbraro, M.; Lawrence, C. C.; Zhu, H.; Pierson, B.; Torres-Isea, R. O.; Becchetti, F. D.; Kolata, J. J.; Riggins, J.

    2015-06-01

    Deuterated scintillators have been used as a tool for neutron spectroscopy without Neutron Time-of-Flight (n-ToF) for more than 30 years. This article will provide a brief historical overview of the technique and current uses of deuterated scintillators in the UM-DSA and DESCANT arrays. Pulse-shape discrimination and spectrum unfolding with the maximum-likelihood expectation maximization algorithm will be discussed. Experimental unfolding and cross section results from measurements of (d,n), (3He,n) and (α,n) reactions are shown.

  11. Contrast-enhanced time-resolved MRA for pre-angiographic evaluation of suspected spinal dural arterial venous fistulas.

    PubMed

    Saindane, Amit M; Boddu, Srikanth R; Tong, Frank C; Dehkharghani, Seena; Dion, Jacques E

    2015-02-01

    Spinal digital subtraction angiography (DSA) is the gold standard for diagnosis of spinal dural arterial venous fistulas (SDAVFs), but can require extensive time, radiation exposure and contrast dose. We hypothesize that contrast-enhanced time-resolved MR angiography (CE-TR MRA) will have utility for the non-invasive diagnosis and pre-angiographic localization of SDAVFs. Eighteen patients underwent both CE-TR MRA and DSA for suspected SDAVFs, with DSA performed a median of 11 days (range 0-41) after MRA. CE-TR MRA was performed on a 1.5 T GE unit using Time Resolved Imaging of Contrast Kinetics (TRICKS). CE-TR MRA and DSA images were evaluated for the presence of SDAVFs and location of the feeding arterial supply, with DSA as the reference standard. DSA was also evaluated for the number of vessels catheterized, contrast volume and fluoroscopic and procedure times. Eight of the 18 patients were positive for SDAVF on DSA. Sensitivity, specificity, positive predictive value and negative predictive value for the 18 CE-TR MRAs were 88%, 90%, 88% and 90%, respectively. Localization of the SDAVF arterial supply on CE-TR MRA was within one vertebral level from DSA for 6/7 SDAVFs. Compared with patients with a SDAVF and feeding artery identified on CE-TR MRA, patients with negative or suboptimal CE-TR MRA had a significantly increased number of vessels catheterized (p=0.027) and larger contrast volumes (p=0.022). CE-TR MRA is a useful initial examination for the diagnosis and localization of SDAVFs, with a high concordance rate with DSA. When CE-TR MRA demonstrates a SDAVF, the number of catheterized vessels and contrast dose can be decreased during DSA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Pre-transplant donor HLA-specific antibodies: characteristics causing detrimental effects on survival after lung transplantation.

    PubMed

    Smith, John D; Ibrahim, Mohamed W; Newell, Helen; Danskine, Anna J; Soresi, Simona; Burke, Margaret M; Rose, Marlene L; Carby, Martin

    2014-10-01

    The impact of Luminex-detected HLA antibodies on outcomes after lung transplantation is unclear. Herein we have undertaken a retrospective study of pre-transplant sera from 425 lung transplants performed between 1991 and 2003. Pre-transplant sera, originally screened by complement-dependent cytotoxicity (CDC) assays, were retrospectively tested for the presence of HLA-specific antibodies using HLA-coated Luminex beads and C4d deposition on Luminex beads. The results were correlated with graft survival at 1 year. Twenty-seven patients were retrospectively identified as having been transplanted against donor-specific HLA antibodies (DSA) and 36 patients against non-donor-specific HLA antibodies (NDSA). DSA-positive patients had 1-year survival of 51.9% compared with 77.8% for NDSA and 71.8% for antibody-negative patients (p = 0.029). One-year survival of patients with complement-fixing DSA was 12.5% compared with 62.5% for non-complement-fixing DSA, 75.8% for non-complement-fixing NDSA and 71.8% for antibody-negative patients (p < 0.0001). DSA-positive patients with mean fluorescence intensity (MFI) >5,000 had 1-year survival of 33.3% compared with 71.4% for MFI 2,000 to 5000 and 62.5% for MFI <2,000 (p = 0.0046). Multivariable analysis revealed DSA to be an independent predictor of poor patient survival within 1 year (p = 0.0010, hazard ratio [HR] = 3.569) as well as complement-fixing DSA (p < 0.0001, HR = 11.083) and DSA with MFI >5,000 (p = 0.0001, HR = 5.512). Pre-formed DSA, particularly complement-fixing DSA, and high MFI are associated with poor survival within the first year after lung transplantation. Risk stratification according to complement fixation or MFI levels may allow for increased transplantation in sensitized patients. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  13. Value of Donor–Specific Anti–HLA Antibody Monitoring and Characterization for Risk Stratification of Kidney Allograft Loss

    PubMed Central

    Viglietti, Denis; Loupy, Alexandre; Vernerey, Dewi; Bentlejewski, Carol; Gosset, Clément; Aubert, Olivier; Duong van Huyen, Jean-Paul; Jouven, Xavier; Legendre, Christophe; Glotz, Denis; Zeevi, Adriana

    2017-01-01

    The diagnosis system for allograft loss lacks accurate individual risk stratification on the basis of donor–specific anti–HLA antibody (anti-HLA DSA) characterization. We investigated whether systematic monitoring of DSA with extensive characterization increases performance in predicting kidney allograft loss. This prospective study included 851 kidney recipients transplanted between 2008 and 2010 who were systematically screened for DSA at transplant, 1 and 2 years post-transplant, and the time of post–transplant clinical events. We assessed DSA characteristics and performed systematic allograft biopsies at the time of post–transplant serum evaluation. At transplant, 110 (12.9%) patients had DSAs; post-transplant screening identified 186 (21.9%) DSA-positive patients. Post–transplant DSA monitoring improved the prediction of allograft loss when added to a model that included traditional determinants of allograft loss (increase in c statistic from 0.67; 95% confidence interval [95% CI], 0.62 to 0.73 to 0.72; 95% CI, 0.67 to 0.77). Addition of DSA IgG3 positivity or C1q binding capacity increased discrimination performance of the traditional model at transplant and post-transplant. Compared with DSA mean fluorescence intensity, DSA IgG3 positivity and C1q binding capacity adequately reclassified patients at lower or higher risk for allograft loss at transplant (category–free net reclassification index, 1.30; 95% CI, 0.94 to 1.67; P<0.001 and 0.93; 95% CI, 0.49 to 1.36; P<0.001, respectively) and post-transplant (category–free net reclassification index, 1.33; 95% CI, 1.03 to 1.62; P<0.001 and 0.95; 95% CI, 0.62 to 1.28; P<0.001, respectively). Thus, pre– and post–transplant DSA monitoring and characterization may improve individual risk stratification for kidney allograft loss. PMID:27493255

  14. Patient radiation dose from computed tomography angiography and digital subtraction angiography of the brain

    NASA Astrophysics Data System (ADS)

    Netwong, Y.; Krisanachinda, A.

    2016-03-01

    The 64-row multidetector computed tomography angiography (64-MDCTA) provides vascular image quality of the brain similar to digital subtraction angiography (DSA), but the effective dose of CTA is lower than DSA studied in phantom. The purpose of this study is to evaluate the effective dose from 64-MDCTA and DSA. Effective dose (according to ICRP 103) from 64-MDCTA and DSA flat panel detector for cerebral vessels examination of the brain using standard protocols as recommended by the manufacturer was calculated for 30 cases of MDCTA (15 male and 15 female).The mean patient age was 49.5 (23-89) yrs. 30 cases of DSA (14 male and 16 female), the mean patient age was 46.8 (21-81) yrs. For CTA, the mean effective dose was 3.7 (2.82- 5.19) mSv. For DSA, the mean effective dose was 5.78 (3.3-10.06) mSv. The effective dose of CTA depends on the scanning protocol and scan length. Low tube current can reduce patient dose whereas the number of exposures and number of series in 3D rotational angiography (3D RA) resulted in increasing effective dose in DSA patients.

  15. [Design and development of the DSA digital subtraction workstation].

    PubMed

    Peng, Wen-Xian; Peng, Tian-Zhou; Xia, Shun-Ren; Jin, Guang-Bo

    2008-05-01

    According to the patient examination criterion and the demands of all related departments, the DSA digital subtraction workstation has been successfully designed and is introduced in this paper by analyzing the characteristic of video source of DSA which was manufactured by GE Company and has no DICOM standard interface. The workstation includes images-capturing gateway and post-processing software. With the developed workstation, all images from this early DSA equipment are transformed into DICOM format and then are shared in different machines.

  16. Renal transplantation across the donor-specific antibody barrier: Graft outcome and cancer risk after desensitization therapy.

    PubMed

    Yang, Ching-Yao; Lee, Chih-Yuan; Yeh, Chi-Chuan; Tsai, Meng-Kun

    2016-06-01

    Desensitization regimens including use of intravenous immune globulin and rituximab have been reported to overcome renal transplant hyperacute rejection. A retrospective case-control study was performed to assess the results and complications of renal transplantation with desensitization therapy for donor-specific antibody (DSA) in a transplant center in Asia, where donor exchange was usually not allowed. Between January 2007 and December 2013, 22 patients with DSA received live-donor renal transplantation after desensitization (DSA group). During the same period, the DSA group was compared to the NSA group (152 renal transplants) who had no specific antibody to the donors (66 from deceased donors and 86 from living relatives). Rejection, renal function, graft and patient survival rates, infection, and cancer incidence were reviewed and analyzed from medical records. The DSA group (46.8%) had significantly higher acute rejection rates than the NSA group (13.7%) at the 1-year follow-up. The estimated renal function, 5-year graft, and patient survival rates were comparable between the groups. The DSA group (19.6%) had significantly higher 5-year de novo cancer incidence than the NSA group (8.5%; p = 0.028); three patients of the DSA group developed urothelial carcinoma 17.0 ± 3.0 months after transplantation. By using stepwise Cox regression analysis, desensitization therapy was identified as the sole independent risk factor for post-transplant urothelial carcinoma. When compared to renal transplantation without DSA, desensitization therapy for DSA resulted in equivalent renal transplant outcome but potentially increased risk of urothelial carcinoma after transplantation. Copyright © 2015. Published by Elsevier B.V.

  17. A high speed implementation of the random decrement algorithm

    NASA Technical Reports Server (NTRS)

    Kiraly, L. J.

    1982-01-01

    The algorithm is useful for measuring net system damping levels in stochastic processes and for the development of equivalent linearized system response models. The algorithm works by summing together all subrecords which occur after predefined threshold level is crossed. The random decrement signature is normally developed by scanning stored data and adding subrecords together. The high speed implementation of the random decrement algorithm exploits the digital character of sampled data and uses fixed record lengths of 2(n) samples to greatly speed up the process. The contributions to the random decrement signature of each data point was calculated only once and in the same sequence as the data were taken. A hardware implementation of the algorithm using random logic is diagrammed and the process is shown to be limited only by the record size and the threshold crossing frequency of the sampled data. With a hardware cycle time of 200 ns and 1024 point signature, a threshold crossing frequency of 5000 Hertz can be processed and a stably averaged signature presented in real time.

  18. Safety, efficacy, and cost of intraoperative indocyanine green angiography compared to intraoperative catheter angiography in cerebral aneurysm surgery.

    PubMed

    Hardesty, Douglas A; Thind, Harjot; Zabramski, Joseph M; Spetzler, Robert F; Nakaji, Peter

    2014-08-01

    Intraoperative angiography in cerebrovascular neurosurgery can drive the repositioning or addition of aneurysm clips. Our institution has switched from a strategy of intraoperative digital subtraction angiography (DSA) universally, to a strategy of indocyanine green (ICG) videoangiography with DSA on an as-needed basis. We retrospectively evaluated whether the rates of perioperative stroke, unexpected postoperative aneurysm residual, or parent vessel stenosis differed in 100 patients from each era (2002, "DSA era"; 2007, "ICG era"). The clip repositioning rate for neck residual or parent vessel stenosis did not differ significantly between the two eras. There were no differences in the rate of perioperative stroke or rate of false-negative studies. The per-patient cost of intraoperative imaging within the DSA era was significantly higher than in the ICG era. The replacement of routine intraoperative DSA with ICG videoangiography and selective intraoperative DSA in cerebrovascular aneurysm surgery is safe and effective. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Optical critical dimension metrology for directed self-assembly assisted contact hole shrink

    NASA Astrophysics Data System (ADS)

    Dixit, Dhairya; Green, Avery; Hosler, Erik R.; Kamineni, Vimal; Preil, Moshe E.; Keller, Nick; Race, Joseph; Chun, Jun Sung; O'Sullivan, Michael; Khare, Prasanna; Montgomery, Warren; Diebold, Alain C.

    2016-01-01

    Directed self-assembly (DSA) is a potential patterning solution for future generations of integrated circuits. Its main advantages are high pattern resolution (˜10 nm), high throughput, no requirement of high-resolution mask, and compatibility with standard fab-equipment and processes. The application of Mueller matrix (MM) spectroscopic ellipsometry-based scatterometry to optically characterize DSA patterned contact hole structures fabricated with phase-separated polystyrene-b-polymethylmethacrylate (PS-b-PMMA) is described. A regression-based approach is used to calculate the guide critical dimension (CD), DSA CD, height of the PS column, thicknesses of underlying layers, and contact edge roughness of the post PMMA etch DSA contact hole sample. Scanning electron microscopy and imaging analysis is conducted as a comparative metric for scatterometry. In addition, optical model-based simulations are used to investigate MM elements' sensitivity to various DSA-based contact hole structures, predict sensitivity to dimensional changes, and its limits to characterize DSA-induced defects, such as hole placement inaccuracy, missing vias, and profile inaccuracy of the PMMA cylinder.

  20. Seismic signature analysis for discrimination of people from animals

    NASA Astrophysics Data System (ADS)

    Damarla, Thyagaraju; Mehmood, Asif; Sabatier, James M.

    2013-05-01

    Cadence analysis has been the main focus for discriminating between the seismic signatures of people and animals. However, cadence analysis fails when multiple targets are generating the signatures. We analyze the mechanism of human walking and the signature generated by a human walker, and compare it with the signature generated by a quadruped. We develop Fourier-based analysis to differentiate the human signatures from the animal signatures. We extract a set of basis vectors to represent the human and animal signatures using non-negative matrix factorization, and use them to separate and classify both the targets. Grazing animals such as deer, cows, etc., often produce sporadic signals as they move around from patch to patch of grass and one must characterize them so as to differentiate their signatures from signatures generated by a horse steadily walking along a path. These differences in the signatures are used in developing a robust algorithm to distinguish the signatures of animals from humans. The algorithm is tested on real data collected in a remote area.

  1. SAR Observation and Numerical Simulation of Internal Solitary Wave Refraction and Reconnection Behind the Dongsha Atoll

    NASA Astrophysics Data System (ADS)

    Jia, T.; Liang, J. J.; Li, X.-M.; Sha, J.

    2018-01-01

    The refraction and reconnection of internal solitary waves (ISWs) around the Dongsha Atoll (DSA) in the northern South China Sea (SCS) are investigated based on spaceborne synthetic aperture radar (SAR) observations and numerical simulations. In general, a long ISW front propagating from the deep basin of the northern SCS splits into northern and southern branches when it passes the DSA. In this study, the statistics of Envisat Advanced SAR (ASAR) images show that the northern and southern wave branches can reconnect behind the DSA, but the reconnection location varies. A previously developed nonlinear refraction model is set up to simulate the refraction and reconnection of the ISWs behind the DSA, and the model is used to evaluate the effects of ocean stratification, background currents, and incoming ISW characteristics at the DSA on the variation in reconnection locations. The results of the first realistic simulation agree with consecutive TerraSAR-X (TSX) images captured within 12 h of each other. Further sensitivity simulations show that ocean stratification, background currents, and initial wave amplitudes all affect the phase speeds of wave branches and therefore shift their reconnection locations while shapes and locations of incoming wave branches upstream of the DSA profoundly influence the subsequent propagation paths. This study clarifies the variation in reconnection locations of ISWs downstream of the DSA and reveals the important mechanisms governing the reconnection process, which can improve our understanding of the propagation of ISWs near the DSA.

  2. The Influence of Immunosuppressive Agents on the Risk of De Novo Donor-Specific HLA Antibody Production in Solid Organ Transplant Recipients

    PubMed Central

    O'Leary, Jacqueline G.; Samaniego, Millie; Barrio, Marta Crespo; Potena, Luciano; Zeevi, Adriana; Djamali, Arjang; Cozzi, Emanuele

    2016-01-01

    Production of de novo donor-specific antibodies (dnDSA) is a major risk factor for acute and chronic antibody-mediated rejection and graft loss after all solid organ transplantation. In this article, we review the data available on the risk of individual immunosuppressive agents and their ability to prevent dnDSA production. Induction therapy with rabbit antithymocyte globulin may achieve a short-term decrease in dnDSA production in moderately sensitized patients. Rituximab induction may be beneficial in sensitized patients, and in abrogating rebound antibody response in patients undergoing desensitization or treatment for antibody-mediated rejection. Use of bortezomib for induction therapy in at-risk patients is of interest, but the benefits are unproven. In maintenance regimens, nonadherent and previously sensitized patients are not suitable for aggressive weaning protocols, particularly early calcineurin inhibitor withdrawal without lymphocyte-depleting induction. Early conversion to mammalian target of rapamycin inhibitor monotherapy has been reported to increase the risk of dnDSA formation, but a combination of mammalian target of rapamycin inhibitor and reduced-exposure calcineurin inhibitor does not appear to alter the risk. Early steroid therapy withdrawal in standard-risk patients after induction has no known dnDSA penalty. The available data do not demonstrate a consistent effect of mycophenolic acid on dnDSA production. Risk minimization for dnDSA requires monitoring of adherence, appropriate risk stratification, risk-based immunosuppression intensity, and prospective DSA surveillance. PMID:26680372

  3. Computed tomography versus digital subtraction angiography for the diagnosis of obscure gastrointestinal bleeding.

    PubMed

    Wildgruber, Moritz; Wrede, Christian E; Zorger, Niels; Müller-Wille, René; Hamer, Okka W; Zeman, Florian; Stroszczynski, Christian; Heiss, Peter

    2017-03-01

    The diagnostic yield of computed tomography angiography (CTA) compared to digital subtraction angiography (DSA) for major obscure gastrointestinal bleeding (OGIB) is not known. Aim of the study was to prospectively evaluate the diagnostic yield of CTA versus DSA for the diagnosis of major OGIB. The institutional review board approved the study and informed consent was obtained from each patient. Patients with major OGIB were prospectively enrolled to undergo both CTA and DSA. Two blinded radiologists each reviewed the CTA and DSA images retrospectively and independently. Contrast material extravasation into the gastrointestinal lumen was considered diagnostic for active bleeding. Primary end point of the study was the diagnostic yield, defined as the frequency a technique identified an active bleeding or a potential bleeding lesion. The diagnostic yield of CTA and DSA were compared by McNemar's test. 24 consecutive patients (11 men; median age 64 years) were included. CTA and DSA identified an active bleeding or a potential bleeding lesion in 92% (22 of 24 patients; 95% CI 72%-99%) and 29% (7 of 24 patients; 95% CI 12%-49%) of patients, respectively (p<0.001). CTA and DSA identified an active bleeding in 42% (10 of 24; 95% CI 22%-63%) and 21% (5 of 24; 95% CI 7%-42%) of patients, respectively (p=0.06). Due to the lower invasiveness and higher diagnostic yield CTA should be favored over DSA for the diagnosis of major OGIB. Copyright © 2016. Published by Elsevier B.V.

  4. Evaluation of algorithms for estimating wheat acreage from multispectral scanner data. [Kansas and Texas

    NASA Technical Reports Server (NTRS)

    Nalepka, R. F. (Principal Investigator); Richardson, W.; Pentland, A. P.

    1976-01-01

    The author has identified the following significant results. Fourteen different classification algorithms were tested for their ability to estimate the proportion of wheat in an area. For some algorithms, accuracy of classification in field centers was observed. The data base consisted of ground truth and LANDSAT data from 55 sections (1 x 1 mile) from five LACIE intensive test sites in Kansas and Texas. Signatures obtained from training fields selected at random from the ground truth were generally representative of the data distribution patterns. LIMMIX, an algorithm that chooses a pure signature when the data point is close enough to a signature mean and otherwise chooses the best mixture of a pair of signatures, reduced the average absolute error to 6.1% and the bias to 1.0%. QRULE run with a null test achieved a similar reduction.

  5. Comparison of reversible methods for data compression

    NASA Astrophysics Data System (ADS)

    Heer, Volker K.; Reinfelder, Hans-Erich

    1990-07-01

    Widely differing methods for data compression described in the ACR-NEMA draft are used in medical imaging. In our contribution we will review various methods briefly and discuss the relevant advantages and disadvantages. In detail we evaluate 1st order DPCM pyramid transformation and S transformation. We compare as coding algorithms both fixed and adaptive Huffman coding and Lempel-Ziv coding. Our comparison is performed on typical medical images from CT MR DSA and DLR (Digital Luminescence Radiography). Apart from the achieved compression factors we take into account CPU time required and main memory requirement both for compression and for decompression. For a realistic comparison we have implemented the mentioned algorithms in the C program language on a MicroVAX II and a SPARC station 1. 2.

  6. Improved cost-effectiveness of the block co-polymer anneal process for DSA

    NASA Astrophysics Data System (ADS)

    Pathangi, Hari; Stokhof, Maarten; Knaepen, Werner; Vaid, Varun; Mallik, Arindam; Chan, Boon Teik; Vandenbroeck, Nadia; Maes, Jan Willem; Gronheid, Roel

    2016-04-01

    This manuscript first presents a cost model to compare the cost of ownership of DSA and SAQP for a typical front end of line (FEoL) line patterning exercise. Then, we proceed to a feasibility study of using a vertical furnace to batch anneal the block co-polymer for DSA applications. We show that the defect performance of such a batch anneal process is comparable to the process of record anneal methods. This helps in increasing the cost benefit for DSA compared to the conventional multiple patterning approaches.

  7. Alloantibodies in Organ Transplant: A Review of Data Published in 2015.

    PubMed

    Maehara, Curtis; Everly, Matthew J

    2015-01-01

    In recent years, there have been multiple studies published on longitudinal and retrospective analysis of anti-human leukocyte antigen (anti-HLA) antibodies. The focus of these reports was to determine specific characteristics of the impact of donor specific anti-HLA antibodies (DSA) in organ transplantation. There has been a growing concern about DSA in a multitude of organ transplants. Research efforts are attempting to gain a better understanding of DSA and possible treatment implications for patients with DSA. In 2015, many studies confirm and expand upon both the understanding of the humoral theory and the clinical applications of DSA in transplantation. This review highlights some of these publications and their contributions to the humoral theory of transplantation. Copyright© 2016 by the Terasaki Foundation Laboratory.

  8. Optical Metrology for Directed Self-assembly Patterning Using Mueller Matrix Spectroscopic Ellipsometry Based Scatterometry

    NASA Astrophysics Data System (ADS)

    Dixit, Dhairya J.

    The semiconductor industry continues to drive patterning solutions that enable devices with higher memory storage capacity, faster computing performance, lower cost per transistors, and higher transistor density. These developments in the field of semiconductor manufacturing along with the overall minimization of the size of transistors require cutting-edge metrology tools for characterization. Directed self-assembly (DSA) patterning process can be used to fabricate nanoscale line-space patterns and contact holes via thermodynamically driven micro-phase separation of block copolymer (BCP) films with boundary constraints from guiding templates. Its main advantages are high pattern resolution (~10 nm), high throughput, no requirement of a high-resolution mask, and compatibility with standard fab-equipment and processes. Although research into DSA patterning has demonstrated a high potential as a nanoscale patterning process, there are critical challenges that must be overcome before transferring DSA into high volume manufacturing, including achievement of low defect density and high process stability. For this, advances in critical dimension (CD) and overlay measurement as well as rapid defect characterization are required. Both scatterometry and critical dimension-scanning electron microscopy (CD-SEM) are routinely used for inline dimensional metrology. CD-SEM inspection is limited, as it does not easily provide detailed line-shape information, whereas scatterometry has the capability of measuring important feature dimensions including: line-width, line-shape, sidewall-angle, and thickness of the patterned samples quickly and non-destructively. The present work describes the application of Mueller matrix spectroscopic ellipsometry (MMSE) based scatterometry to optically characterize DSA patterned line- space grating and contact hole structures fabricated with phase-separated polystyrene-b-polymethylmethacrylate (PS-b-PMMA) at various integration steps of BCP DSA based patterning process. This work focuses on understanding the efficacy of MMSE base scatterometry for characterizing complex DSA structures. For example, the use of symmetry-antisymmetry properties associated with Mueller matrix (MM) elements to understand the topography of the periodic nanostructures and measure defectivity. Simulations (the forward problem approach of scatterometry) are used to investigate MM elements' sensitivity to changes in DSA structure such as one vs. two contact hole patterns and predict sensitivity to dimensional changes. A regression-based approach is used to extract feature shape parameters of the DSA structures by fitting simulated optical spectra to experimental optical spectra. Detection of the DSA defects is a key to reducing defect density for eventual manufacturability and production use of DSA process. Simulations of optical models of structures containing defects are used to evaluate the sensitivity of MM elements to DSA defects. This study describes the application of MMSE to determine the DSA pattern defectivity via spectral comparisons based on optical anisotropy and depolarization. The use of depolarization and optical anisotropy for characterization of experimental MMSE data is a very recent development in scatterometry. In addition, reconstructed scatterometry models are used to calculate line edge roughness in 28 nm pitch Si fins fabricated using DSA patterning process.

  9. CHEMINFORMATICS TOOLS FOR TOXICANT CHARACTERIZATION

    EPA Science Inventory

    • Continued development of the Shape Signatures method is planed.  This effort will include further development of the Shape Signatures database of PDB-extracted ligands and of the clustering algorithm.
    • In addition, we plan to develop an...

    • The Effects of a Dynamic Spectrum Access Overlay in LTE-Advanced Networks

      DOE Office of Scientific and Technical Information (OSTI.GOV)

      Juan D. Deaton; Ryan E. lrwin; Luiz A. DaSilva

      As early as 2014, wireless network operators spectral capacity will be overwhelmed by a data tsunami brought on by new devices and applications. To augment spectral capacity, operators could deploy a Dynamic Spectrum Access (DSA) overlay. In the light of the many planned Long Term Evolution (LTE) network deployments, the affects of a DSA overlay have not been fully considered into the existing LTE standards. Coalescing many different aspects of DSA, this paper develops the Spectrum Accountability (SA) framework. The SA framework defines specific network element functionality, protocol interfaces, and signaling flow diagrams for LTE to support service requests andmore » enforce rights of responsibilities of primary and secondary users, respectively. We also include a network simulation to quantify the benefits of using DSA channels to augment capacity. Based on our simulation we show that, network operators can benefit up to %40 increase in operating capacity when sharing DSA bands to augment spectral capacity. With our framework, this paper could serve as an guide in developing future LTE network standards that include DSA.« less

    • The European Society for Blood and Marrow Transplantation (EBMT) Consensus Guidelines for the Detection and Treatment of Donor-specific Anti-HLA Antibodies (DSA) in Haploidentical Hematopoietic Cell Transplantation.

      PubMed

      Ciurea, Stefan O; Cao, Kai; Fernadez-Vina, Marcelo; Kongtim, Piyanuch; Malki, Monzr Al; Fuchs, Ephraim; Luznik, Leo; Huang, Xiao-Jun; Ciceri, Fabio; Locatelli, Franco; Aversa, Franco; Castagna, Luca; Bacigalupo, Andrea; Martelli, Massimo; Blaise, Didier; Handgretinger, Rupert; Roy, Denis-Claude; O'Donnell, Paul; Bashey, Asad; Lazarus, Hillard M; Ballen, Karen; Savani, Bipin N; Mohty, Mohamad; Nagler, Arnon

      2018-05-01

      Haploidentical donors are now increasingly considered for transplantation in the absence of HLA-matched donors or when an urgent transplant is needed. Donor-specific anti-HLA antibodies (DSA) have been recently recognized as an important barrier against successful engraftment of donor cells, which can affect transplant survival. DSA appear more prevalent in this type of transplant due to higher likelihood of alloimmunization of multiparous females against offspring's HLA antigens, and the degree of mismatch. Here we summarize the evidence for the role of DSA in the development of primary graft failure in haploidentical transplantation and provide consensus recommendations from the European Society for Blood and Marrow Transplant Group on testing, monitoring, and treatment of patients with DSA receiving haploidentical hematopoietic progenitor cell transplantation.

    • Comparison of C-arm Computed Tomography and Digital Subtraction Angiography in Patients with Chronic Thromboembolic Pulmonary Hypertension

      DOE Office of Scientific and Technical Information (OSTI.GOV)

      Hinrichs, Jan B., E-mail: hinrichs.jan@mh-hannover.de; Marquardt, Steffen, E-mail: marquardt.steffen@mh-hannover.de; Falck, Christian von, E-mail: falck.christian.von@mh-hannover.de

      PurposeTo assess the feasibility and diagnostic performance of contrast-enhanced, C-arm computed tomography (CACT) of the pulmonary arteries compared to digital subtraction angiography (DSA) in patients suffering from chronic thromboembolic pulmonary hypertension (CTEPH).MaterialsFifty-two patients with CTEPH underwent ECG-gated DSA and contrast-enhanced CACT. Two readers (R1, R2) independently evaluated pulmonary artery segments and their sub-segmental branching using DSA and CACT for optimal image quality. Afterwards, the diagnostic findings, i.e., intraluminal filling defects, stenosis, and occlusion, were compared. Inter-modality and inter-observer agreement was calculated, and subsequently consensus reading was done and correlated to a reference standard representing the overall consensus of both modalities.more » Fisher’s exact test and Cohen’s Kappa were applied.ResultsA total of 1352 pulmonary segments were evaluated, of which 1255 (92.8 %) on DSA and 1256 (92.9 %) on CACT were rated to be fully diagnostic. The main causes of the non-diagnostic image quality were motion artifacts on CACT (R1:37, R2:78) and insufficient contrast enhancement on DSA (R1:59, R2:38). Inter-observer agreement was good for DSA (κ = 0.74) and CACT (κ = 0.75), while inter-modality agreement was moderate (R1: κ = 0.46, R2: κ = 0.47). Compared to the reference standard, the inter-modality agreement for CACT was excellent (κ = 0.96), whereas it was inferior for DSA (κ = 0.61) due to the higher number of abnormal consensus findings read as normal on DSA.ConclusionCACT of the pulmonary arteries is feasible and provides additional information to DSA. CACT has the potential to improve the diagnostic work-up of patients with CTEPH and may be particularly useful prior to surgical or interventional treatment.« less

    • Four-dimensional computed tomography angiographic evaluation of cranial dural arteriovenous fistula before and after embolization.

      PubMed

      Tian, Bing; Xu, Bing; Lu, Jianping; Liu, Qi; Wang, Li; Wang, Minjie

      2015-06-01

      This study aimed to evaluate the usefulness of four-dimensional CTA before and after embolization treatment with ONYX-18 in eleven patients with cranial dural arteriovenous fistulas, and to compare the results with those of the reference standard DSA. Eleven patients with cranial dural arteriovenous fistulas detected on DSA underwent transarterial embolization with ONYX-18. Four-dimensional CTA was performed an average of 2 days before and 4 days after DSA. Four-dimensional CTA and DSA images were reviewed by two neuroradiologists for identification of feeding arteries and drainage veins and for determining treatment effects. Interobserver and intermodality agreement between four-dimensional CTA and DSA were assessed. Forty-two feeding arteries were identified for 14 fistulas in the 11 patients. Of these, 36 (85.71%) were detected on four-dimensional CTA. After transarterial embolization, one patient got partly embolized, and the fistulas in the remaining 10 patients were completely occluded. The interobserver agreement for four-dimensional CTA and intermodality agreement between four-dimensional CTA and DSA were excellent (κ=1) for shunt location, identification of drainage veins, and fistula occlusion after treatment. Four-dimensional CTA images are highly accurate when compared with DSA images both before and after transarterial embolization treatment. Four-dimensional CTA can be used for diagnosis as well as follow-up of cranial dural arteriovenous fistulas in clinical settings. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

    • A Modified Mechanical Threshold Stress Constitutive Model for Austenitic Stainless Steels

      NASA Astrophysics Data System (ADS)

      Prasad, K. Sajun; Gupta, Amit Kumar; Singh, Yashjeet; Singh, Swadesh Kumar

      2016-12-01

      This paper presents a modified mechanical threshold stress (m-MTS) constitutive model. The m-MTS model incorporates variable athermal and dynamic strain aging (DSA) Components to accurately predict the flow stress behavior of austenitic stainless steels (ASS)-316 and 304. Under strain rate variations between 0.01-0.0001 s-1, uniaxial tensile tests were conducted at temperatures ranging from 50-650 °C to evaluate the material constants of constitutive models. The test results revealed the high dependence of flow stress on strain, strain rate and temperature. In addition, it was observed that DSA occurred at elevated temperatures and very low strain rates, causing an increase in flow stress. While the original MTS model is capable of predicting the flow stress behavior for ASS, statistical parameters point out the inefficiency of the model when compared to other models such as Johnson Cook model, modified Zerilli-Armstrong (m-ZA) model, and modified Arrhenius-type equations (m-Arr). Therefore, in order to accurately model both the DSA and non-DSA regimes, the original MTS model was modified by incorporating variable athermal and DSA components. The suitability of the m-MTS model was assessed by comparing the statistical parameters. It was observed that the m-MTS model was highly accurate for the DSA regime when compared to the existing models. However, models like m-ZA and m-Arr showed better results for the non-DSA regime.

    • High risk of graft failure in patients with anti-HLA antibodies undergoing haploidentical stem-cell transplantation.

      PubMed

      Ciurea, Stefan O; de Lima, Marcos; Cano, Pedro; Korbling, Martin; Giralt, Sergio; Shpall, Elizabeth J; Wang, Xuemei; Thall, Peter F; Champlin, Richard E; Fernandez-Vina, Marcelo

      2009-10-27

      BACKGROUND.: Although donor-specific anti-human leukocyte antigen (HLA) antibodies (DSA) have been implicated in graft rejection in solid organ transplantation, their role in hematopoietic stem-cell transplantation remains unclear. METHODS.: To address the hypothesis that the presence of DSA contributes to the development graft failure, we tested 24 consecutive patients for the presence of anti-HLA antibodies determined by a sensitive and specific solid-phase/single-antigen assay. The study included a total of 28 haploidentical transplants, each with 2 to 5 HLA allele mismatches, at a single institution, from September 2005 to August 2008. RESULTS.: DSA were detected in five patients (21%). Three of four (75%) patients with DSA before the first transplant failed to engraft, compared with 1 of 20 (5%) without DSA (P=0.008). All four patients who experienced primary graft failure had second haploidentical transplants. One patient developed a second graft failure with persistent high DSA levels, whereas three engrafted, two of them in the absence of DSA. No other known factors that could negatively influence engraftment were associated with the development of graft failure in these patients. CONCLUSIONS.: These results suggest that donor-specific anti-HLA antibodies are associated with a high rate of graft rejection in patients undergoing haploidentical stem-cell transplantation. Anti-HLA sensitization should be evaluated routinely in hematopoietic stem-cell transplantation with HLA mismatched donors.

    • Diffusive Shock Acceleration and Turbulent Reconnection

      NASA Astrophysics Data System (ADS)

      Garrel, Christian; Vlahos, Loukas; Isliker, Heinz; Pisokas, Theophilos

      2018-05-01

      Diffusive Shock Acceleration (DSA) cannot efficiently accelerate particles without the presence of self-consistently generated or pre-existing strong turbulence (δB/B ˜ 1) in the vicinity of the shock. The problem we address in this article is: if large amplitude magnetic disturbances are present upstream and downstream of a shock then Turbulent Reconnection (TR) will set in and will participate not only in the elastic scattering of particles but also in their heating and acceleration. We demonstrate that large amplitude magnetic disturbances and Unstable Current Sheets (UCS), spontaneously formed in the strong turbulence in the vicinity of a shock, can accelerate particles as efficiently as DSA in large scale systems and on long time scales. We start our analysis with "elastic" scatterers upstream and downstream and estimate the energy distribution of particles escaping from the shock, recovering the well known results from the DSA theory. Next we analyze the additional interaction of the particles with active scatterers (magnetic disturbances and UCS) upstream and downstream of the shock. We show that the asymptotic energy distribution of the particles accelerated by DSA/TR has very similar characteristics with the one due to DSA alone, but the synergy of DSA with TR is much more efficient: The acceleration time is an order of magnitude shorter and the maximum energy reached two orders of magnitude higher. We claim that DSA is the dominant acceleration mechanism in a short period before TR is established, and then strong turbulence will dominate the heating and acceleration of the particles. In other words, the shock serves as the mechanism to set up a strongly turbulent environment, in which the acceleration mechanism will ultimately be the synergy of DSA and TR.

    • Contrast-enhanced time-resolved MRA for follow-up of intracranial aneurysms treated with the pipeline embolization device.

      PubMed

      Boddu, S R; Tong, F C; Dehkharghani, S; Dion, J E; Saindane, A M

      2014-01-01

      Endovascular reconstruction and flow diversion by using the Pipeline Embolization Device is an effective treatment for complex cerebral aneurysms. Accurate noninvasive alternatives to DSA for follow-up after Pipeline Embolization Device treatment are desirable. This study evaluated the accuracy of contrast-enhanced time-resolved MRA for this purpose, hypothesizing that contrast-enhanced time-resolved MRA will be comparable with DSA and superior to 3D-TOF MRA. During a 24-month period, 37 Pipeline Embolization Device-treated intracranial aneurysms in 26 patients underwent initial follow-up by using 3D-TOF MRA, contrast-enhanced time-resolved MRA, and DSA. MRA was performed on a 1.5T unit by using 3D-TOF and time-resolved imaging of contrast kinetics. All patients underwent DSA a median of 0 days (range, 0-68) after MRA. Studies were evaluated for aneurysm occlusion, quality of visualization of the reconstructed artery, and measurable luminal diameter of the Pipeline Embolization Device, with DSA used as the reference standard. The sensitivity, specificity, and positive and negative predictive values of contrast-enhanced time-resolved MRA relative to DSA for posttreatment aneurysm occlusion were 96%, 85%, 92%, and 92%. Contrast-enhanced time-resolved MRA demonstrated superior quality of visualization (P = .0001) and a higher measurable luminal diameter (P = .0001) of the reconstructed artery compared with 3D-TOF MRA but no significant difference compared with DSA. Contrast-enhanced time-resolved MRA underestimated the luminal diameter of the reconstructed artery by 0.965 ± 0.497 mm (27% ± 13%) relative to DSA. Contrast-enhanced time-resolved MRA is a reliable noninvasive method for monitoring intracranial aneurysms following flow diversion and vessel reconstruction by using the Pipeline Embolization Device. © 2014 by American Journal of Neuroradiology.

    • DOE Office of Scientific and Technical Information (OSTI.GOV)

      Schernthaner, Ruediger Egbert; Lin, MingDe; Duran, Rafael

      PurposeTo evaluate the detectability of intrahepatic cholangiocarcinoma (ICC) on dual-phase cone-beam CT (DPCBCT) during conventional transarterial chemoembolization (cTACE) compared to that of digital subtraction angiography (DSA) with respect to pre-procedure contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver.MethodsThis retrospective study included 17 consecutive patients (10 male, mean age 64) with ICC who underwent pre-procedure CE-MRI of the liver, and DSA and DPCBCT (early-arterial phase (EAP) and delayed-arterial phase (DAP)) just before cTACE. The visibility of each ICC lesion was graded by two radiologists on a three-rank scale (complete, partial, and none) on DPCBCT and DSA images, and then compared tomore » pre-procedure CE-MRI.ResultsOf 61 ICC lesions, only 45.9 % were depicted by DSA, whereas EAP- and DAP-CBCT yielded a significantly higher detectability rate of 73.8 % and 93.4 %, respectively (p < 0.01). Out of the 33 lesions missed on DSA, 18 (54.5 %) and 30 (90.9 %) were revealed on EAP- and DAP-CBCT images, respectively. DSA depicted only one lesion that was missed by DPCBCT due to streak artifacts caused by a prosthetic mitral valve. DAP-CBCT identified significantly more lesions than EAP-CBCT (p < 0.01). Conversely, EAP-CBCT did not detect lesions missed by DAP-CBCT. For complete lesion visibility, DAP-CBCT yielded significantly higher detectability (78.7 %) compared to EAP (31.1 %) and DSA (21.3 %) (p < 0.01).ConclusionDPCBCT, and especially the DAP-CBCT, significantly improved the detectability of ICC lesions during cTACE compared to DSA. We recommend the routine use of DAP-CBCT in patients with ICC for per-procedure detectability and treatment planning in the setting of TACE.« less

    • Perioperative Desensitization Improves Outcomes Among Crossmatch Positive Recipients of Deceased Donor Renal Transplants.

      PubMed

      Sharma, Amit; King, Anne; Kumar, Dhiren; Behnke, Martha; McDougan, Felecia; Kimball, Pamela M

      2016-06-01

      Graft failure due to chronic rejection is greater among renal transplant patients with donor-specific antibody (DSA) than among DSA-free patients. For patients dependent on deceased donor transplantation, preoperative desensitization to eliminate DSAs may be impractical. We speculated that perioperative desensitization might eliminate preexisting DSAs and prevent de novo DSAs and improve graft outcomes. We report that brief perioperative desensitization using either intravenous immunoglobulin (IVIG) or plasmapheresis/IVIG (PP/IVIG) treatment improves clinical outcomes among patients with positive crossmatches. Immediately following deceased donor transplantation, 235 renal recipients were assigned points for PRA and flow crossmatches (FCXM): delayed graft function (DGF) ≤ 1 point received standard therapy; 2 points received high-dose IVIG; and ≥3 points received PP/IVIG. The DSAs were serially monitored by single antigen bead luminex for 1 year. Five-year clinical outcomes were determined from the chart review. All desensitized patients had preoperatively positive FCXM with DSA. Rejection was more common (P < .05) among desensitized than nonsensitized groups. However, overall graft survivals were similar between the groups (P = not significant) and superior to historic untreated patients (P < .05). Treatment with PP/IVIG more effectively eliminated preexisting DSAs (67% vs 33%, P < 0.05) than IVIG, but neither regimen prevented de novo formation of DSA (20%, P = not significant). Graft survival was >90% in all desensitizated patients with DSA elimination as well as PP/IVIG patients with residual DSA. In contrast, IVIG patients with persistent DSA had poorer graft survival (45%, P < .05). Preemptive perioperative desensitization improved overall graft survival of sensitized patients compared to historic untreated patients. Plasmapheresis/IVIG had greater impact on DSA eradication and graft survival than IVIG alone. © 2016, NATCO.

    • The Drug Safety and Risk Management Advisory Committee: a case study of meeting frequency, content, and outcomes before and after FDAAA.

      PubMed

      Morrato, Elaine H; Ling, Sarah B

      2012-11-01

      The Food and Drug Administration Amendments Act (FDAAA) of 2007 granted FDA-expanded drug safety authority. We hypothesized that meetings involving the FDA Drug Safety and Risk Management (DSaRM) Advisory Committee might serve as a barometer for the impact of FDAAA on drug safety regulatory decision making. We conducted a case study analysis of 42 DSaRM advisory committee meetings held between 2002 and 2011. Publicly available sources (FDA meeting minutes and materials, safety alerts, and drug manufacturer Web sites) were reviewed to describe and compare DSaRM meeting frequency, content and outcomes between the pre-FDAAA (2002-2007) and post-FDAAA (2008-2011) periods. DSaRM meeting frequency increased after FDAAA (from 2.7 to 6.5 meetings per year). DSaRM meetings were more likely to be held jointly with other drug advisory committees after FDAAA (from 68% to 92% of meetings). DSaRM members were invited participants in 35 additional meetings of other drug advisory committees (2007-2011). DSaRM meetings were more likely to review issues of approvability (eg, new drugs, new indications, and new product formulations) after FDAAA. FDA questions to the committee were more likely to request an explicit drug safety assessment after FDAAA (from 31% to 76% of meetings). Content analysis of meeting outcomes and subsequent FDA regulatory decisions did not suggest a more or less risk aversive climate after FDAAA. Increased DSaRM advisory committee activity indicates its advice was being sought more broadly for drug regulatory decision making and at earlier stages of drug development after FDAAA was enacted.

  1. Equine deep stromal abscesses (51 cases - 2004-2009)--Part 1: the clinical aspects with attention to the duration of the corneal disease, treatment history, clinical appearance, and microbiology results.

    PubMed

    de Linde Henriksen, Michala; Andersen, Pia H; Thomsen, Preben D; Plummer, Caryn E; Mangan, Brendan; Heegaard, Steffen; Toft, Nils; Brooks, Dennis E

    2014-07-01

    To study the equine deep stromal abscesses (DSA) with focus on the duration of the corneal disease, medical treatment, season of presentation, clinical appearance, and the degree of corneal vascularization. Equine DSA diagnosed, biopsied, and surgically treated at the University of Florida Veterinary Medical Center (UFVMC) from 2004 to 2009 were identified. The medical record, clinical photographic images, and microbiology results for each case were evaluated. Frequency and prevalence calculation as well as qualitative data analysis was performed for clinical and microbiological data. Fifty-one equine DSA were included in the study. Spring (March, April, May; 33.4%) and winter (December, January, February; 31.4%) were the most common seasons for DSA presentation. The 51 cases were divided into four categories of focal opacity from their clinical appearance: focal yellow (45.2%), focal white (23.5%), diffuse yellow/white (23.5%), and focal pink (7.8%). 5.9% of the DSA (n = 3) were culture positive for fungal growth, whereas 17.6% were positive for bacterial growth (n = 9). No association between short-/long-term systemically administered NSAID treatment and the corneal vascular response to the corneal lesion could be appreciated. Equine DSA most often present in the spring and winter in the subtropical environment of the state of Florida (USA). The clinical appearance may have a connection with the etiology and pathogenesis of the equine DSA. No connection between short- or long-term systemically administered NSAID and the degree of corneal vascularization of the DSA was noted. © 2013 American College of Veterinary Ophthalmologists.

  2. Comparison of High-Resolution MR Imaging and Digital Subtraction Angiography for the Characterization and Diagnosis of Intracranial Artery Disease.

    PubMed

    Lee, N J; Chung, M S; Jung, S C; Kim, H S; Choi, C-G; Kim, S J; Lee, D H; Suh, D C; Kwon, S U; Kang, D-W; Kim, J S

    2016-12-01

    High-resolution MR imaging has recently been introduced as a promising diagnostic modality in intracranial artery disease. Our aim was to compare high-resolution MR imaging with digital subtraction angiography for the characterization and diagnosis of various intracranial artery diseases. Thirty-seven patients who had undergone both high-resolution MR imaging and DSA for intracranial artery disease were enrolled in our study (August 2011 to April 2014). The time interval between the high-resolution MR imaging and DSA was within 1 month. The degree of stenosis and the minimal luminal diameter were independently measured by 2 observers in both DSA and high-resolution MR imaging, and the results were compared. Two observers independently diagnosed intracranial artery diseases on DSA and high-resolution MR imaging. The time interval between the diagnoses on DSA and high-resolution MR imaging was 2 weeks. Interobserver diagnostic agreement for each technique and intermodality diagnostic agreement for each observer were acquired. High-resolution MR imaging showed moderate-to-excellent agreement (interclass correlation coefficient = 0.892-0.949; κ = 0.548-0.614) and significant correlations (R = 0.766-892) with DSA on the degree of stenosis and minimal luminal diameter. The interobserver diagnostic agreement was good for DSA (κ = 0.643) and excellent for high-resolution MR imaging (κ = 0.818). The intermodality diagnostic agreement was good (κ = 0.704) for observer 1 and moderate (κ = 0.579) for observer 2, respectively. High-resolution MR imaging may be an imaging method comparable with DSA for the characterization and diagnosis of various intracranial artery diseases. © 2016 by American Journal of Neuroradiology.

  3. Incorporate Imaging Characteristics Into an Arteriovenous Malformation Radiosurgery Plan Evaluation Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang Pengpeng; Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY; Wu, Leester

    Purpose: To integrate imaging performance characteristics, specifically sensitivity and specificity, of magnetic resonance angiography (MRA) and digital subtraction angiography (DSA) into arteriovenous malformation (AVM) radiosurgery planning and evaluation. Methods and Materials: Images of 10 patients with AVMs located in critical brain areas were analyzed in this retrospective planning study. The image findings were first used to estimate the sensitivity and specificity of MRA and DSA. Instead of accepting the imaging observation as a binary (yes or no) mapping of AVM location, our alternative is to translate the image into an AVM probability distribution map by incorporating imagers' sensitivity and specificity,more » and to use this map as a basis for planning and evaluation. Three sets of radiosurgery plans, targeting the MRA and DSA positive overlap, MRA positive, and DSA positive were optimized for best conformality. The AVM obliteration rate (ORAVM) and brain complication rate served as endpoints for plan comparison. Results: In our 10-patient study, the specificities and sensitivities of MRA and DSA were estimated to be (0.95, 0.74) and (0.71, 0.95), respectively. The positive overlap of MRA and DSA accounted for 67.8% {+-} 4.9% of the estimated true AVM volume. Compared with plans targeting MRA and DSA-positive overlap, plans targeting MRA-positive or DSA-positive improved ORAVM by 4.1% {+-} 1.9% and 15.7% {+-} 8.3%, while also increasing the complication rate by 1.0% {+-} 0.8% and 4.4% {+-} 2.3%, respectively. Conclusions: The impact of imagers' quality should be quantified and incorporated in AVM radiosurgery planning and evaluation to facilitate clinical decision making.« less

  4. Pretransplant soluble CD30 is a better predictor of posttransplant development of donor-specific antibodies and acute vascular rejection than panel reactive antibodies.

    PubMed

    Vaidya, Smita; Partlow, David; Barnes, Titus; Gugliuzza, Kristine

    2006-12-27

    This study tests a hypothesis that pretransplant concentration of soluble CD30 (sCD30) is a better predictor of posttransplant development of donor-specific HLA antibodies (DSA) and acute vascular rejection (AVR) than panel reactive HLA antibodies (PRA). Pretransplant sera from 115 patients were evaluated for their PRA and sCD30 concentrations. All patients received calcineurin-inhibitor based immunosuppressive therapy. Objective measurements for rejection were biopsy-proven AVR episodes within first 6 months of the transplant. Posttransplant sera of patients with or without AVR were tested for the presence of DSA. AVR rate was 16% (18/115). Patients positive for PRA and sCD30 tests were at significantly higher risk for AVR compared to those patients negative for both tests (36% versus 5%, p = 0.01). Among negative PRA patients risk for AR was significantly elevated if they were also tested positive for sCD30 concentrations (21% versus 5%, p = 0.04). Of the 18 patients with AVR, 14 were positive for sCD30, and 13 of them (93%) developed DSA posttransplant (p = 0.001) Nineteen patients without AVR were tested for DSA and sCD30 concentrations. Only two of these 19 patients were positive for sCD30 and DSA. AVR was strongly associated with the patients tested positive for both the tests: DSA and sCD30 (p = 0.00007). Furthermore, patients with AVR are more likely to produce DSA than those without AVR (p = 0.02). These data support our hypothesis that patients positive for sCD30 contents are at high risk the development of DSA and AVR posttransplant regardless of their pretransplant PRA.

  5. 76 FR 11433 - Federal Transition To Secure Hash Algorithm (SHA)-256

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-02

    ... generating digital signatures. Current information systems, Web servers, applications and workstation operating systems were designed to process, and use SHA-1 generated signatures. National Institute of... cryptographic keys, and more robust algorithms by December 2013. Government systems may begin to encounter...

  6. Assessment of Gamma-Ray-Spectra Analysis Method Utilizing the Fireworks Algorithm for Various Error Measures

    DOE PAGES

    Alamaniotis, Miltiadis; Tsoukalas, Lefteri H.

    2018-01-01

    The analysis of measured data plays a significant role in enhancing nuclear nonproliferation mainly by inferring the presence of patterns associated with special nuclear materials. Among various types of measurements, gamma-ray spectra is the widest utilized type of data in nonproliferation applications. In this paper, a method that employs the fireworks algorithm (FWA) for analyzing gamma-ray spectra aiming at detecting gamma signatures is presented. In particular, FWA is utilized to fit a set of known signatures to a measured spectrum by optimizing an objective function, where non-zero coefficients express the detected signatures. FWA is tested on a set of experimentallymore » obtained measurements optimizing various objective functions—MSE, RMSE, Theil-2, MAE, MAPE, MAP—with results exhibiting its potential in providing highly accurate and precise signature detection. Finally and furthermore, FWA is benchmarked against genetic algorithms and multiple linear regression, showing its superiority over those algorithms regarding precision with respect to MAE, MAPE, and MAP measures.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prinsloo, P. L.; Potgieter, M. S.; Strauss, R. D., E-mail: marius.potgieter@nwu.ac.za

    Observations by the Voyager spacecraft in the outer heliosphere presented several challenges for the paradigm of diffusive shock acceleration (DSA) at the solar wind termination shock (TS). In this study, the viability of DSA as a re-acceleration mechanism for galactic electrons is investigated using a comprehensive cosmic-ray modulation model. The results demonstrate that the efficiency of DSA depends strongly on the shape of the electron spectra incident at the TS, which in turn depends on the features of the local interstellar spectrum. Modulation processes such as drifts therefore also influence the re-acceleration process. It is found that re-accelerated electrons makemore » appreciable contributions to intensities in the heliosphere and that increases caused by DSA at the TS are comparable to intensity enhancements observed by Voyager 1 ahead of the TS crossing. The modeling results are interpreted as support for DSA as a re-acceleration mechanism for galactic electrons at the TS.« less

  8. Directed Self-Assembly on Photo-Crosslinked Polystyrene Sub-Layers: Nanopattern Uniformity and Orientation

    PubMed Central

    Koh, Haeng-Deog; Kim, Mi-Jeong

    2016-01-01

    A photo-crosslinked polystyrene (PS) thin film is investigated as a potential guiding sub-layer for polystyrene-block-poly (methyl methacrylate) block copolymer (BCP) cylindrical nanopattern formation via topographic directed self-assembly (DSA). When compared to a non-crosslinked PS brush sub-layer, the photo-crosslinked PS sub-layer provided longer correlation lengths of the BCP nanostructure, resulting in a highly uniform DSA nanopattern with a low number of BCP dislocation defects. Depending on the thickness of the sub-layer used, parallel or orthogonal orientations of DSA nanopattern arrays were obtained that covered the entire surface of patterned Si substrates, including both trench and mesa regions. The design of DSA sub-layers and guide patterns, such as hardening the sub-layer by photo-crosslinking, nano-structuring on mesas, the relation between trench/mesa width, and BCP equilibrium period, were explored with a view to developing defect-reduced DSA lithography technology. PMID:28773768

  9. Online signature recognition using principal component analysis and artificial neural network

    NASA Astrophysics Data System (ADS)

    Hwang, Seung-Jun; Park, Seung-Je; Baek, Joong-Hwan

    2016-12-01

    In this paper, we propose an algorithm for on-line signature recognition using fingertip point in the air from the depth image acquired by Kinect. We extract 10 statistical features from X, Y, Z axis, which are invariant to changes in shifting and scaling of the signature trajectories in three-dimensional space. Artificial neural network is adopted to solve the complex signature classification problem. 30 dimensional features are converted into 10 principal components using principal component analysis, which is 99.02% of total variances. We implement the proposed algorithm and test to actual on-line signatures. In experiment, we verify the proposed method is successful to classify 15 different on-line signatures. Experimental result shows 98.47% of recognition rate when using only 10 feature vectors.

  10. Machine learning algorithm accurately detects fMRI signature of vulnerability to major depression.

    PubMed

    Sato, João R; Moll, Jorge; Green, Sophie; Deakin, John F W; Thomaz, Carlos E; Zahn, Roland

    2015-08-30

    Standard functional magnetic resonance imaging (fMRI) analyses cannot assess the potential of a neuroimaging signature as a biomarker to predict individual vulnerability to major depression (MD). Here, we use machine learning for the first time to address this question. Using a recently identified neural signature of guilt-selective functional disconnection, the classification algorithm was able to distinguish remitted MD from control participants with 78.3% accuracy. This demonstrates the high potential of our fMRI signature as a biomarker of MD vulnerability. Crown Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Multislice CT Angiography in Renal Artery Stent Evaluation: Prospective Comparison with Intra-Arterial Digital Subtraction Angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona

    2004-01-15

    Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, themore » DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography.« less

  12. Offline Signature Verification Using the Discrete Radon Transform and a Hidden Markov Model

    NASA Astrophysics Data System (ADS)

    Coetzer, J.; Herbst, B. M.; du Preez, J. A.

    2004-12-01

    We developed a system that automatically authenticates offline handwritten signatures using the discrete Radon transform (DRT) and a hidden Markov model (HMM). Given the robustness of our algorithm and the fact that only global features are considered, satisfactory results are obtained. Using a database of 924 signatures from 22 writers, our system achieves an equal error rate (EER) of 18% when only high-quality forgeries (skilled forgeries) are considered and an EER of 4.5% in the case of only casual forgeries. These signatures were originally captured offline. Using another database of 4800 signatures from 51 writers, our system achieves an EER of 12.2% when only skilled forgeries are considered. These signatures were originally captured online and then digitally converted into static signature images. These results compare well with the results of other algorithms that consider only global features.

  13. A comparative study of Message Digest 5(MD5) and SHA256 algorithm

    NASA Astrophysics Data System (ADS)

    Rachmawati, D.; Tarigan, J. T.; Ginting, A. B. C.

    2018-03-01

    The document is a collection of written or printed data containing information. The more rapid advancement of technology, the integrity of a document should be kept. Because of the nature of an open document means the document contents can be read and modified by many parties so that the integrity of the information as a content of the document is not preserved. To maintain the integrity of the data, it needs to create a mechanism which is called a digital signature. A digital signature is a specific code which is generated from the function of producing a digital signature. One of the algorithms that used to create the digital signature is a hash function. There are many hash functions. Two of them are message digest 5 (MD5) and SHA256. Those both algorithms certainly have its advantages and disadvantages of each. The purpose of this research is to determine the algorithm which is better. The parameters which used to compare that two algorithms are the running time and complexity. The research results obtained from the complexity of the Algorithms MD5 and SHA256 is the same, i.e., ⊖ (N), but regarding the speed is obtained that MD5 is better compared to SHA256.

  14. Anti-huCD20 Antibody Therapy for Antibody-Mediated Rejection of Renal Allografts in a Mouse Model

    PubMed Central

    Abe, Toyofumi; Ishii, Daisuke; Gorbacheva, Victoria; Kohei, Naoki; Tsuda, Hidetoshi; Tanaka, Toshiaki; Dvorina, Nina; Nonomura, Norio; Takahara, Shiro; Valujskikh, Anna; Baldwin, William M.; Fairchild, Robert L.

    2016-01-01

    We have reported that B6.CCR5−/− mice reject renal allografts with high serum donor-specific antibody (DSA) titers and marked C4d deposition in grafts, features consistent with AMR. B6.huCD20/CCR5−/− mice, where human CD20 expression is restricted to B cells, rejected A/J renal allografts by day 26 post-transplant with DSA first detected in serum on day 5 post-transplant and increased thereafter. Recipient treatment with anti-huCD20 mAb prior to the transplant and weekly up to 7 weeks post-transplant promoted long-term allograft survival (> 100 days) with low DSA titers. To investigate the effect of B cell depletion at the time serum DSA was first detected, recipients were treated with anti-huCD20 mAb on days 5, 8 and 12 post-transplant. This regimen significantly reduced DSA titers and graft inflammation on day 15 post-transplant and prolonged allograft survival > 60 days. However, DSA returned to the titers observed in control treated recipients by day 30 post-transplant and histological analyses on day 60 post-transplant indicated severe interstitial fibrosis. These results indicate that anti-huCD20 mAb had the greatest effect as a prophylactic treatment and that the distinct kinetics of DSA responses accounts for acute renal allograft failure versus the development of fibrosis. PMID:25731734

  15. The Presence of Pretransplant HLA Antibodies Does Not Impact the Development of Chronic Lung Allograft Dysfunction or CLAD-Related Death.

    PubMed

    Zazueta, Oscar E; Preston, Sara E; Moniodis, Anna; Fried, Sabrina; Kim, Miae; Townsend, Keri; Wood, Isabelle; Boukedes, Steve; Guleria, Indira; Camp, Phillip; El-Chemaly, Souheil; Rosas, Ivan O; Chandraker, Anil; Milford, Edgar; Goldberg, Hilary J

    2017-09-01

    Development of donor-specific antibodies (DSA) after lung transplantation is associated with antibody mediated rejection, acute cellular rejection, and bronchiolitis obliterans syndrome; however, the significance of circulating antibodies before transplant remains unclear. We performed a retrospective cohort study including recipients of primary lung transplants between 2008 and 2012. We assessed the impact of circulating HLA and noncytotoxic DSA detected before transplant on development of Chronic Lung Allograft Dysfunction (CLAD) or CLAD-related death. 30% of subjects had circulating class I antibodies alone, 4% Class II, and 14.4% class I and class II at mean fluorescent intensity greater than 1000. Nine percent of the subjects had DSA class I, 9% class II, and 2.4% both DSA classes 1 and 2. Neither the presence of circulating antibodies (adjusted hazard ratio, 0.87; 95% confidence interval, 0.50-1.54) nor the presence of DSA (adjusted hazard ratio, 1.56; 95% confidence interval, 0.77-3.18) before transplant at mean fluorescent intensity greater than 1000 was associated with the development of CLAD or CLAD-related death. Although in previous studies we have shown an increased incidence of antibody-mediated rejection in patients with pretransplant DSA, neither the presence of HLA antibodies nor DSA translated to an increased risk of allograft dysfunction or death if prospective crossmatch testing was negative. Prospective studies are needed to define the impact of pretransplant sensitization on lung transplant recipients.

  16. Noninvasive, automatic optimization strategy in cardiac resynchronization therapy.

    PubMed

    Reumann, Matthias; Osswald, Brigitte; Doessel, Olaf

    2007-07-01

    Optimization of cardiac resynchronization therapy (CRT) is still unsolved. It has been shown that optimal electrode position,atrioventricular (AV) and interventricular (VV) delays improve the success of CRT and reduce the number of non-responders. However, no automatic, noninvasive optimization strategy exists to date. Cardiac resynchronization therapy was simulated on the Visible Man and a patient data-set including fiber orientation and ventricular heterogeneity. A cellular automaton was used for fast computation of ventricular excitation. An AV block and a left bundle branch block were simulated with 100%, 80% and 60% interventricular conduction velocity. A right apical and 12 left ventricular lead positions were set. Sequential optimization and optimization with the downhill simplex algorithm (DSA) were carried out. The minimal error between isochrones of the physiologic excitation and the therapy was computed automatically and leads to an optimal lead position and timing. Up to 1512 simulations were carried out per pathology per patient. One simulation took 4 minutes on an Apple Macintosh 2 GHz PowerPC G5. For each electrode pair an optimal pacemaker delay was found. The DSA reduced the number of simulations by an order of magnitude and the AV-delay and VV - delay were determined with a much higher resolution. The findings are well comparable with clinical studies. The presented computer model of CRT automatically evaluates an optimal lead position and AV-delay and VV-delay, which can be used to noninvasively plan an optimal therapy for an individual patient. The application of the DSA reduces the simulation time so that the strategy is suitable for pre-operative planning in clinical routine. Future work will focus on clinical evaluation of the computer models and integration of patient data for individualized therapy planning and optimization.

  17. Benign Prostatic Hyperplasia: Cone-Beam CT in Conjunction with DSA for Identifying Prostatic Arterial Anatomy.

    PubMed

    Wang, Mao Qiang; Duan, Feng; Yuan, Kai; Zhang, Guo Dong; Yan, Jieyu; Wang, Yan

    2017-01-01

    Purpose To describe findings in prostatic arteries (PAs) at digital subtraction angiography (DSA) and cone-beam computed tomography (CT) that allow identification of benign prostatic hyperplasia and to determine the value added with the use of cone-beam CT. Materials and Methods This retrospective single-institution study was approved by the institutional review board, and the requirement for written informed consent was waived. From February 2009 to December 2014, a total of 148 patients (mean age ± standard deviation, 70.5 years ± 14.5) underwent DSA of the internal iliac arteries and cone-beam CT with a flat-detector angiographic system before they underwent prostate artery embolization. Both the DSA and cone-beam CT images were evaluated by two interventional radiologists to determine the number of independent PAs and their origins and anastomoses with adjacent arteries. The exact McNemar test was used to compare the detection rate of the PAs and the anastomoses with DSA and with cone-beam CT. Results The PA anatomy was evaluated successfully by means of cone-beam CT in conjunction with DSA in all patients. Of the 296 pelvic sides, 274 (92.6%) had only one PA. The most frequent PA origin was the common gluteal-pudendal trunk with the superior vesicular artery in 118 (37.1%), followed by the anterior division of the internal iliac artery in 99 (31.1%), and the internal pudendal artery in 77 (24.2%) pelvic sides. In 67 (22.6%) pelvic sides, anastomoses to adjacent arteries were documented. The numbers of PA origins and anastomoses, respectively, that could be identified were significantly higher with cone-beam CT (301 of 318 [94.7%] and 65 of 67 [97.0%]) than with DSA (237 [74.5%] and 39 [58.2%], P < .05). Cone-beam CT provided essential information that was not available with DSA in 90 of 148 (60.8%) patients. Conclusion Cone-beam CT is a useful adjunctive technique to DSA for identification of the PA anatomy and provides information to help treatment planning during prostatic arterial embolization. © RSNA, 2016.

  18. Simulating realistic predator signatures in quantitative fatty acid signature analysis

    USGS Publications Warehouse

    Bromaghin, Jeffrey F.

    2015-01-01

    Diet estimation is an important field within quantitative ecology, providing critical insights into many aspects of ecology and community dynamics. Quantitative fatty acid signature analysis (QFASA) is a prominent method of diet estimation, particularly for marine mammal and bird species. Investigators using QFASA commonly use computer simulation to evaluate statistical characteristics of diet estimators for the populations they study. Similar computer simulations have been used to explore and compare the performance of different variations of the original QFASA diet estimator. In both cases, computer simulations involve bootstrap sampling prey signature data to construct pseudo-predator signatures with known properties. However, bootstrap sample sizes have been selected arbitrarily and pseudo-predator signatures therefore may not have realistic properties. I develop an algorithm to objectively establish bootstrap sample sizes that generates pseudo-predator signatures with realistic properties, thereby enhancing the utility of computer simulation for assessing QFASA estimator performance. The algorithm also appears to be computationally efficient, resulting in bootstrap sample sizes that are smaller than those commonly used. I illustrate the algorithm with an example using data from Chukchi Sea polar bears (Ursus maritimus) and their marine mammal prey. The concepts underlying the approach may have value in other areas of quantitative ecology in which bootstrap samples are post-processed prior to their use.

  19. On the way to total integration of prosthetic pylon with residuum

    PubMed Central

    Pitkin, Mark

    2010-01-01

    Two decades after introducing threaded titanium dental implants, Dr. Per-Ingvar Brånemark used a similar technique in the 1980s to pioneer the direct skeletal attachment (DSA) of limb prostheses. He and his colleagues used convincing clinical experience to overcome the skepticism of their peers, affording a new dimension of prosthetic rehabilitation to almost 100 individuals with amputation. As a result, more research has been initiated worldwide to move DSA to a level of greater safety, longevity, and reliability. This review highlights the trends and milestones in current DSA development. It also identifies ideas from previous studies in various fields that may be useful in future DSA development. PMID:19675987

  20. Motion compensation in digital subtraction angiography using graphics hardware.

    PubMed

    Deuerling-Zheng, Yu; Lell, Michael; Galant, Adam; Hornegger, Joachim

    2006-07-01

    An inherent disadvantage of digital subtraction angiography (DSA) is its sensitivity to patient motion which causes artifacts in the subtraction images. These artifacts could often reduce the diagnostic value of this technique. Automated, fast and accurate motion compensation is therefore required. To cope with this requirement, we first examine a method explicitly designed to detect local motions in DSA. Then, we implement a motion compensation algorithm by means of block matching on modern graphics hardware. Both methods search for maximal local similarity by evaluating a histogram-based measure. In this context, we are the first who have mapped an optimizing search strategy on graphics hardware while paralleling block matching. Moreover, we provide an innovative method for creating histograms on graphics hardware with vertex texturing and frame buffer blending. It turns out that both methods can effectively correct the artifacts in most case, as the hardware implementation of block matching performs much faster: the displacements of two 1024 x 1024 images can be calculated at 3 frames/s with integer precision or 2 frames/s with sub-pixel precision. Preliminary clinical evaluation indicates that the computation with integer precision could already be sufficient.

  1. Arterial Blood Flow Measurement Using Digital Subtraction Angiography (DSA)

    NASA Astrophysics Data System (ADS)

    Swanson, David K.; Myerowitz, P. David; Van Lysel, Michael S.; Peppler, Walter W.; Fields, Barry L.; Watson, Kim M.; O'Connor, Julia

    1984-08-01

    Standard angiography demonstrates the anatomy of arterial occlusive disease but not its physiological signficance. Using intravenous digital subtraction angiography (DSA), we investigated transit-time videodensitometric techniques in measuring femoral arterial flows in dogs. These methods have been successfully applied to intraarterial DSA but not to intravenous DSA. Eight 20 kg dogs were instrumented with an electromagnetic flow probe and a balloon occluder above an imaged segment of femoral artery. 20 cc of Renografin 76 was power injected at 15 cc/sec into the right atrium. Flow in the femoral artery was varied by partial balloon occlusion or peripheral dilatation following induced ischemia resulting in 51 flow measurements varying from 15 to 270 cc/min. Three different transit-time techniques were studied: crosscorrelation, mean square error, and two leading edge methods. Correlation between videodensitometry and flowmeter measurements using these different techniques ranged from 0.78 to 0.88 with a mean square error of 29 to 37 cc/min. Blood flow information using several different transit-time techniques can be obtained with intravenous DSA.

  2. A novel algorithm for simplification of complex gene classifiers in cancer

    PubMed Central

    Wilson, Raphael A.; Teng, Ling; Bachmeyer, Karen M.; Bissonnette, Mei Lin Z.; Husain, Aliya N.; Parham, David M.; Triche, Timothy J.; Wing, Michele R.; Gastier-Foster, Julie M.; Barr, Frederic G.; Hawkins, Douglas S.; Anderson, James R.; Skapek, Stephen X.; Volchenboum, Samuel L.

    2013-01-01

    The clinical application of complex molecular classifiers as diagnostic or prognostic tools has been limited by the time and cost needed to apply them to patients. Using an existing fifty-gene expression signature known to separate two molecular subtypes of the pediatric cancer rhabdomyosarcoma, we show that an exhaustive iterative search algorithm can distill this complex classifier down to two or three features with equal discrimination. We validated the two-gene signatures using three separate and distinct data sets, including one that uses degraded RNA extracted from formalin-fixed, paraffin-embedded material. Finally, to demonstrate the generalizability of our algorithm, we applied it to a lung cancer data set to find minimal gene signatures that can distinguish survival. Our approach can easily be generalized and coupled to existing technical platforms to facilitate the discovery of simplified signatures that are ready for routine clinical use. PMID:23913937

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Segal-Peretz, Tamar; Zhou, Chun; Ren, Jiaxing

    The three-dimensional assembly of poly (styrene-b-methyl methacrylate) (PS-b-PMMA) in chemoepitaxy and graphoepitaxy directed self-assembly (DSA) was investigated using scanning transmission electron microscopy (STEM) tomography. The tomographic characterization revealed hidden morphologies and defects at the BCP- chemical pattern interface in lamellar DSA, and probed the formation of cylinders at the bottom of cylindrical DSA for contact hole shrink. Lastly, future work will include control over 3D assembly in sub-10 nm processes.

  4. A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT.

    PubMed

    Badea, Cristian T; Hedlund, Laurence W; Johnson, G Allan

    2013-01-01

    CT and digital subtraction angiography (DSA) are ubiquitous in the clinic. Their preclinical equivalents are valuable imaging methods for studying disease models and treatment. We have developed a dual source/detector X-ray imaging system that we have used for both micro-CT and DSA studies in rodents. The control of such a complex imaging system requires substantial software development for which we use the graphical language LabVIEW (National Instruments, Austin, TX, USA). This paper focuses on a LabVIEW platform that we have developed to enable anatomical and functional imaging with micro-CT and DSA. Our LabVIEW applications integrate and control all the elements of our system including a dual source/detector X-ray system, a mechanical ventilator, a physiological monitor, and a power microinjector for the vascular delivery of X-ray contrast agents. Various applications allow cardiac- and respiratory-gated acquisitions for both DSA and micro-CT studies. Our results illustrate the application of DSA for cardiopulmonary studies and vascular imaging of the liver and coronary arteries. We also show how DSA can be used for functional imaging of the kidney. Finally, the power of 4D micro-CT imaging using both prospective and retrospective gating is shown for cardiac imaging.

  5. A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT

    PubMed Central

    Badea, Cristian T.; Hedlund, Laurence W.; Johnson, G. Allan

    2013-01-01

    CT and digital subtraction angiography (DSA) are ubiquitous in the clinic. Their preclinical equivalents are valuable imaging methods for studying disease models and treatment. We have developed a dual source/detector X-ray imaging system that we have used for both micro-CT and DSA studies in rodents. The control of such a complex imaging system requires substantial software development for which we use the graphical language LabVIEW (National Instruments, Austin, TX, USA). This paper focuses on a LabVIEW platform that we have developed to enable anatomical and functional imaging with micro-CT and DSA. Our LabVIEW applications integrate and control all the elements of our system including a dual source/detector X-ray system, a mechanical ventilator, a physiological monitor, and a power microinjector for the vascular delivery of X-ray contrast agents. Various applications allow cardiac- and respiratory-gated acquisitions for both DSA and micro-CT studies. Our results illustrate the application of DSA for cardiopulmonary studies and vascular imaging of the liver and coronary arteries. We also show how DSA can be used for functional imaging of the kidney. Finally, the power of 4D micro-CT imaging using both prospective and retrospective gating is shown for cardiac imaging. PMID:27006920

  6. Assessment of blood supply to intracranial pathologies in children using MR digital subtraction angiography.

    PubMed

    Chooi, Weng Kong; Connolly, Dan J A; Coley, Stuart C; Griffiths, Paul D

    2006-10-01

    MR digital subtraction angiography (MR-DSA) is a contrast-enhanced MR angiographic sequence that enables time-resolved evaluation of the cerebral circulation. We describe the feasibility and technical success of our attempts at MR-DSA for the assessment of intracranial pathology in children. We performed MR-DSA in 15 children (age range 5 days to 16 years) referred for MR imaging because of known or suspected intracranial pathology that required a dynamic assessment of the cerebral vasculature. MR-DSA consisted of a thick (6-10 mm) slice-selective RF-spoiled fast gradient-echo sequence (RF-FAST) acquired before and during passage of an intravenously administered bolus of Gd-DTPA. The images were subtracted and viewed as a cine loop. MR-DSA was performed successfully in all patients. High-flow lesions were shown in four patients; these included vein of Galen aneurysmal malformation, dural fistula, and two partially treated arteriovenous malformations (AVMs). Low-flow lesions were seen in three patients, all of which were tumours. Normal flow was confirmed in eight patients including two with successfully treated AVMs, and in three patients with cavernomas. Our early experience suggests that MR-DSA is a realistic, non-invasive alternative to catheter angiography in certain clinical settings.

  7. Study on Dynamic Strain Aging and Low-Cycle Fatigue of Stainless Steel in Ultra-Supercritical Unit

    NASA Astrophysics Data System (ADS)

    Hongwei, Zhou; Yizhu, He; Jizu, Lv; Sixian, Rao

    Dynamic strain aging (DSA) and low-cycle fatigue (LCF) behavior of TP347H stainless steel in ultra-supercritical unit were investigated at 550-650 °C. All the LCF tests were carried out under a fully-reversed, total axial strain control mode at the total strain amplitude from ±0.2% to ±1.0%. The effects of DSA in cyclic stress response, microstructure evolution and fatigue fracture surfaces and fatigue life were investigated in detail. The results show that DSA occurs during tensile, which is manifested as serrated flow in tensile stress-strain curves. The apparent activation energy for appearing of serrations in tensile stress-strain curves was 270 kJ/mol. Pipe diffusion of substitutional solutes such as Cr and Nb along the dislocation core, and strong interactions between segregated solutes and dislocations are considered as the mechanism of DSA. DSA partly restricts dislocation cross-slip, and dislocation cross-slip and planar-slip happen simultaneously during LCF. A lot of planar structures form, which is due to dislocation gliding on the special plane. This localized deformation structures result in many crack initiation sites. Meanwhile, DSA hardening increases cyclic stress response, accelerating crack propagation, which reduces high temperature strain fatigue life of steel.

  8. Comparison of Intraoperative Indocyanine Green Angiography and Digital Subtraction Angiography for Clipping of Intracranial Aneurysms

    PubMed Central

    Doss, Vinodh T.; Goyal, Nitin; Humphries, William; Hoit, Dan; Arthur, Adam; Elijovich, Lucas

    2015-01-01

    Background Residual aneurysm after microsurgical clipping carries a risk of aneurysm growth and rupture. Digital subtraction angiography (DSA) remains the standard to determine the adequacy of clipping. Intraoperative indocyanine green (ICG) angiography is increasingly utilized to confirm optimal clip positioning across the neck and to evaluate the adjacent vasculature. Objective We evaluated the correlation between ICG and DSA in clipped intracranial aneurysms. Methods A retrospective study of patients who underwent craniotomy and microsurgical clipping of intracranial aneurysms with ICG for 2 years. Patient characteristics, presentation details, operative reports, and pre- and postclipping angiographic images were reviewed to determine the adequacy of the clipping. Results Forty-seven patients underwent clipping with ICG and postoperative DSA: 57 aneurysms were clipped; 23 patients (48.9%) presented with subarachnoid hemorrhage. Nine aneurysms demonstrated a residual on DSA not identified on ICG (residual sizes ranged from 0.5 to 4.3 mm; average size: 1.8 mm). Postoperative DSA demonstrated no branch occlusions. Conclusion Intraoperative ICG is useful in the clipping of intracranial aneurysms to ensure a gross patency of branch vessels; however, the presence of residual aneurysms and subtle changes in flow in branch vessels is best seen by DSA. This has important clinical implications with regard to follow-up imaging and surgical/endovascular management. PMID:26279659

  9. Standardized volume rendering for magnetic resonance angiography measurements in the abdominal aorta.

    PubMed

    Persson, A; Brismar, T B; Lundström, C; Dahlström, N; Othberg, F; Smedby, O

    2006-03-01

    To compare three methods for standardizing volume rendering technique (VRT) protocols by studying aortic diameter measurements in magnetic resonance angiography (MRA) datasets. Datasets from 20 patients previously examined with gadolinium-enhanced MRA and with digital subtraction angiography (DSA) for abdominal aortic aneurysm were retrospectively evaluated by three independent readers. The MRA datasets were viewed using VRT with three different standardized transfer functions: the percentile method (Pc-VRT), the maximum-likelihood method (ML-VRT), and the partial range histogram method (PRH-VRT). The aortic diameters obtained with these three methods were compared with freely chosen VRT parameters (F-VRT) and with maximum intensity projection (MIP) concerning inter-reader variability and agreement with the reference method DSA. F-VRT parameters and PRH-VRT gave significantly higher diameter values than DSA, whereas Pc-VRT gave significantly lower values than DSA. The highest interobserver variability was found for F-VRT parameters and MIP, and the lowest for Pc-VRT and PRH-VRT. All standardized VRT methods were significantly superior to both MIP and F-VRT in this respect. The agreement with DSA was best for PRH-VRT, which was the only method with a mean error below 1 mm and which also had the narrowest limits of agreement (95% of cases between 2.1 mm below and 3.1 mm above DSA). All the standardized VRT methods compare favorably with MIP and VRT with freely selected parameters as regards interobserver variability. The partial range histogram method, although systematically overestimating vessel diameters, gives results closest to those of DSA.

  10. Assessment of Gamma-Ray Spectra Analysis Method Utilizing the Fireworks Algorithm for various Error Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alamaniotis, Miltiadis; Tsoukalas, Lefteri H.

    2018-01-01

    Significant role in enhancing nuclear nonproliferation plays the analysis of obtained data and the inference of the presence or not of special nuclear materials in them. Among various types of measurements, gamma-ray spectra is the widest used type of data utilized for analysis in nonproliferation. In this chapter, a method that employs the fireworks algorithm (FWA) for analyzing gamma-ray spectra aiming at detecting gamma signatures is presented. In particular FWA is utilized to fit a set of known signatures to a measured spectrum by optimizing an objective function, with non-zero coefficients expressing the detected signatures. FWA is tested on amore » set of experimentally obtained measurements and various objective functions -MSE, RMSE, Theil-2, MAE, MAPE, MAP- with results exhibiting its potential in providing high accuracy and high precision of detected signatures. Furthermore, FWA is benchmarked against genetic algorithms, and multiple linear regression with results exhibiting its superiority over the rest tested algorithms with respect to precision for MAE, MAPE and MAP measures.« less

  11. A comparison between DART-MS and DSA-MS in the forensic analysis of writing inks.

    PubMed

    Drury, Nicholas; Ramotowski, Robert; Moini, Mehdi

    2018-05-23

    Ambient ionization mass spectrometry is gaining momentum in forensic science laboratories because of its high speed of analysis, minimal sample preparation, and information-rich results. One such application of ambient ionization methodology includes the analysis of writing inks from questioned documents where colorants of interest may not be soluble in common solvents, rendering thin layer chromatography (TLC) and separation-mass spectrometry methods such as LC/MS (-MS) impractical. Ambient ionization mass spectrometry uses a variety of ionization techniques such as penning ionization in Direct Analysis in Real Time (DART), and atmospheric pressure chemical ionization in Direct Sample Analysis (DSA), and electrospray ionization in Desorption Electrospray Ionization (DESI). In this manuscript, two of the commonly used ambient ionization techniques are compared: Perkin Elmer DSA-MS and IonSense DART in conjunction with a JEOL AccuTOF MS. Both technologies were equally successful in analyzing writing inks and produced similar spectra. DSA-MS produced less background signal likely because of its closed source configuration; however, the open source configuration of DART-MS provided more flexibility for sample positioning for optimum sensitivity and thereby allowing smaller piece of paper containing writing ink to be analyzed. Under these conditions, the minimum sample required for DART-MS was 1mm strokes of ink on paper, whereas DSA-MS required a minimum of 3mm. Moreover, both techniques showed comparable repeatability. Evaluation of the analytical figures of merit, including sensitivity, linear dynamic range, and repeatability, for DSA-MS and DART-MS analysis is provided. To the forensic context of the technique, DART-MS was applied to the analysis of United States Secret Service ink samples directly on a sampling mesh, and the results were compared with DSA-MS of the same inks on paper. Unlike analysis using separation mass spectrometry, which requires sample preparation, both DART-MS and DSA-MS successfully analyzed writing inks with minimal sample preparation. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Comparison of hepatic MDCT, MRI, and DSA to explant pathology for the detection and treatment planning of hepatocellular carcinoma.

    PubMed

    Ladd, Lauren M; Tirkes, Temel; Tann, Mark; Agarwal, David M; Johnson, Matthew S; Tahir, Bilal; Sandrasegaran, Kumaresan

    2016-12-01

    The diagnosis and treatment plan for hepatocellular carcinoma (HCC) can be made from radiologic imaging. However, lesion detection may vary depending on the imaging modality. This study aims to evaluate the sensitivities of hepatic multidetector computed tomography (MDCT), magnetic resonance imaging (MRI), and digital subtraction angiography (DSA) in the detection of HCC and the consequent management impact on potential liver transplant patients. One hundred and sixteen HCC lesions were analyzed in 41 patients who received an orthotopic liver transplant (OLT). All of the patients underwent pretransplantation hepatic DSA, MDCT, and/or MRI. The imaging results were independently reviewed retrospectively in a blinded fashion by two interventional and two abdominal radiologists. The liver explant pathology was used as the gold standard for assessing each imaging modality. The sensitivity for overall HCC detection was higher for cross-sectional imaging using MRI (51.5%, 95% confidence interval [CI]=36.2-58.4%) and MDCT (49.8%, 95% CI=43.7-55.9%) than for DSA (41.7%, 95% CI=36.2-47.3%) ( P =0.05). The difference in false-positive rate was not statistically significant between MRI (22%), MDCT (29%), and DSA (29%) ( P =0.67). The sensitivity was significantly higher for detecting right lobe lesions than left lobe lesions for all modalities (MRI: 56.1% vs. 43.1%, MDCT: 55.0% vs. 42.0%, and DSA: 46.9% vs. 33.9%; all P <0.01). The sensitivities of the three imaging modalities were also higher for lesions ≥2 cm vs. <2 cm (MRI: 73.4% vs. 32.7%, MDCT: 66.9% vs. 33.8%, and DSA: 62.2% vs. 24.1%; all P <0.01). The interobserver correlation was rated as very good to excellent. The sensitivity for detecting HCC is higher for MRI and MDCT than for DSA, and so cross-sectional imaging modalities should be used to evaluate OLT candidacy.

  13. 2012 annual literature review of donor-specific HLA antibodies after organ transplantation.

    PubMed

    Kaneku, Hugo

    2012-01-01

    From the articles reviewed in the present chapter, we observed: 1. The frequency of de novo donor-specific human leukocyte antigen (HLA) antibodies (DSA) detection in different organs is very similar: ranging between 15% and 23% in kidney, 23% in pancreas, and 18% in intestinal transplant patients. Apparently, all organs can elicit humoral responses after transplantation at comparable rates. 2. Although rates of de novo DSA formation after kidney transplantation are very similar across different centers--between 15% and 23%--, the mean time to the first detection of de novo DSA is markedly variable between centers (from 8 months to 4 years). Some differences found in the studies that may account for this could be the age of patients (studies including pediatric patients tend to show longer time to DSA detection compared to studies only including adults patients), patients' race, and maintenance immunosuppression regimens. 3. In most organs, alloantibodies against class II HLA--and especially against HLA-DQ antigens--are the most common DSA detected. This finding supports previous studies, but the explanation remains unclear. Poor HLA-DQ matching, paucity of class II HLA antigen expression on cell surface, and technical factors related to the detection of these antibodies (mean fluorescence intensity cutoff, multiple beads with the same antigen, denatured protein on single antigen beads) are some of the potential explanations that need further investigation. 4. Recent focus on histological changes during rejection in the presence of DSA that are independent of C4d deposition may change how antibody-mediated rejection is diagnosed in the near future. 5. More studies are looking into the importance of DSA in non-kidney transplants and now evidence shows that DSA may not only affect survival and rejection rates, but may also be associated with organ-specific lesions like fibrosis and biliary complications in livers or capillaritis in lungs.

  14. A moment projection method for population balance dynamics with a shrinkage term

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Shaohua; Yapp, Edward K.Y.; Akroyd, Jethro

    A new method of moments for solving the population balance equation is developed and presented. The moment projection method (MPM) is numerically simple and easy to implement and attempts to address the challenge of particle shrinkage due to processes such as oxidation, evaporation or dissolution. It directly solves the moment transport equation for the moments and tracks the number of the smallest particles using the algorithm by Blumstein and Wheeler (1973) . The performance of the new method is measured against the method of moments (MOM) and the hybrid method of moments (HMOM). The results suggest that MPM performs muchmore » better than MOM and HMOM where shrinkage is dominant. The new method predicts mean quantities which are almost as accurate as a high-precision stochastic method calculated using the established direct simulation algorithm (DSA).« less

  15. Detecting and visualizing weak signatures in hyperspectral data

    NASA Astrophysics Data System (ADS)

    MacPherson, Duncan James

    This thesis evaluates existing techniques for detecting weak spectral signatures from remotely sensed hyperspectral data. Algorithms are presented that successfully detect hard-to-find 'mystery' signatures in unknown cluttered backgrounds. The term 'mystery' is used to describe a scenario where the spectral target and background endmembers are unknown. Sub-Pixel analysis and background suppression are used to find deeply embedded signatures which can be less than 10% of the total signal strength. Existing 'mystery target' detection algorithms are derived and compared. Several techniques are shown to be superior both visually and quantitatively. Detection performance is evaluated using confidence metrics that are developed. A multiple algorithm approach is shown to improve detection confidence significantly. Although the research focuses on remote sensing applications, the algorithms presented can be applied to a wide variety of diverse fields such as medicine, law enforcement, manufacturing, earth science, food production, and astrophysics. The algorithms are shown to be general and can be applied to both the reflective and emissive parts of the electromagnetic spectrum. The application scope is a broad one and the final results open new opportunities for many specific applications including: land mine detection, pollution and hazardous waste detection, crop abundance calculations, volcanic activity monitoring, detecting diseases in food, automobile or airplane target recognition, cancer detection, mining operations, extracting galactic gas emissions, etc.

  16. Dark Skies Awareness Cornerstone Project for the International Year of Astronomy

    NASA Astrophysics Data System (ADS)

    Walker, C. E.; Pompea, S. M.; Iya Dark Skies Awareness Working Group

    2010-12-01

    Programs that were part of the International Year of Astronomy 2009 (IYA2009) Dark Skies Awareness (DSA) Cornerstone Project have been successfully implemented around the world to promote social awareness of the effects of light pollution on public health, economic issues, ecological consequences, energy conservation, safety and security, nightscape aesthetics and especially astronomy. In developing the programs, DSA Cornerstone Project found that to influence cultural change effectively — to make people literally look up and see the light — we must make children a main focus, use approaches that offer involvement on many levels, from cursory to committed, and offer involvement via many venues. We must make the programs and resources as turn-key as possible, especially for educators — and provide ways to visualize the problem with simple, easily grasped demonstrations. The programs spanned a wide range; from new media technology for the younger generation, to an event in the arts, to various types of educational materials, to the promotion of dark skies communities, to national and international events and to global citizen science programs. The DSA Cornerstone Project is continuing most all of these programs beyond IYA2009. The International Dark-Sky Association as well as the Starlight Initiative is endorsing and helping to continue with some of the most successful programs from the DSA. The GLOBE at Night campaign is adding a research component that examines light pollution’s affects on wildlife. Dark Skies Rangers activities are being implemented in Europe through the Galileo Teacher Training Program. The new “One Star at a Time” will engage people to protect the night sky through personal pledges and registration of public stargazing areas or StarParks, like the newest one in Italy. The Starlight Initiative’s World Night in Defence of the Starlight will take place on the Vernal Equinox. DSA will again oversee the Dark Skies portion of Global Astronomy Month, in which the International Dark Sky Week will be celebrated. DSA will be collaborating with Belgium’s “Night of Darkness” to endeavor to make that lights out event a more global event. DSA will endeavor to support dark skies education worldwide, as in Northern Ireland. DSA will seek to expand light pollution prevention campaigns like Austria’s. People whose homes meet the criteria of good lighting are invited to put a sticker from Austria’s biggest newspaper in their front window to show their support. DSA also seeks to collaborate with the IAU Office for Astronomy Development. The presentation will focus on the DSA programs during IYA and the sustainability of the DSA programs after IYA, as well as the expansion to other programs worldwide, with particular emphasis in communicating dark skies awareness with the public and its educational value in attracting young people to study science and technology. See www.darkskiesawareness.org for more information on the programs.

  17. A retrospective analysis of environmental risk factors for the diagnosis of deep stromal abscess in 390 horses in North Central Florida from 1991 to 2013.

    PubMed

    Proietto, Laura R; Plummer, Caryn E; Maxwell, Kathleen M; Lamb, Kenneth E; Brooks, Dennis E

    2016-07-01

    The purpose of this investigation was to identify potential environmental risk factors for the diagnosis of equine deep stromal abscesses (DSA) in the subtropical climate at the University of Florida Veterinary Medical Center (UFVMC). Cases included were selected from the UFVMC medical record and imaging database, and included all cases of equine DSA diagnosed during the period from December 1991 to December 2013 in patients residing in north central Florida. Patient date of diagnosis and atmospheric data was obtained for north central Florida for the corresponding time period. Univariate and multivariate general linear models were generated testing effects and interactions between environmental conditions. When year, sulfur dioxide (SO2 ) and wind were analyzed in the presence of each other, a one-mile per hour increase in wind (P = 0.005) significantly increased the number of DSA cases by 1.63 cases per year. When the influence of temperature was evaluated in conjunction with year and nitrogen dioxide (NO2 ), the number of cases decreased by 0.1534 per year for every degree increase in temperature (°C) (P = 0.039). Wind speed is the first significant atmospheric risk factor to be identified for DSA formation in the horse. The importance of environmental variance in the incidence of DSA indicates that the pathogenesis of DSA formation may be multifactorial, interdependent and provides support in some horses for the micropuncture hypothesis of DSA formation related to the involvement of environmental conditions causing precorneal tear film and epithelial damage. © 2015 American College of Veterinary Ophthalmologists.

  18. Flat-detector computed tomography evaluation in an experimental animal aneurysm model after endovascular treatment: A pilot study.

    PubMed

    Ott, Sabine; Gölitz, Philipp; Adamek, Edyta; Royalty, Kevin; Doerfler, Arnd; Struffert, Tobias

    2015-08-01

    We compared flat-detector computed tomography angiography (FD-CTA) to multislice computed tomography (MS-CTA) and digital subtracted angiography (DSA) for the visualization of experimental aneurysms treated with stents, coils or a combination of both.In 20 rabbits, aneurysms were created using the rabbit elastase aneurysm model. Seven aneurysms were treated with coils, seven with coils and stents, and six with self-expandable stents alone. Imaging was performed by DSA, MS-CTA and FD-CTA immediately after treatment. Multiplanar reconstruction (MPR) was performed and two experienced reviewers compared aneurysm/coil package size, aneurysm occlusion, stent diameters and artifacts for each modality.In aneurysms treated with stents alone, the visualization of the aneurysms was identical in all three imaging modalities. Residual aneurysm perfusion was present in two cases and visible in DSA and FD-CTA but not in MS-CTA. The diameter of coil-packages was overestimated in MS-CT by 56% and only by 16% in FD-CTA compared to DSA (p < 0.05). The diameter of stents was identical for DSA and FD-CTA and was significantly overestimated in MS-CTA (p < 0.05). Beam/metal hardening artifacts impaired image quality more severely in MS-CTA compared to FD-CTA.MS-CTA is impaired by blooming and beam/metal hardening artifacts in the visualization of implanted devices. There was no significant difference between measurements made with noninvasive FD-CTA compared to gold standard of DSA after stenting and after coiling/stent-assisted coiling of aneurysms. FD-CTA may be considered as a non-invasive alternative to the gold standard 2D DSA in selected patients that require follow up imaging after stenting. © The Author(s) 2015.

  19. Voluntary Exercise Impairs Initial Delayed Spatial Alternation Performance in Estradiol Treated Ovariectomized Middle-Aged Rats

    PubMed Central

    Neese, Steven L.; Korol, Donna L.; Schantz, Susan L.

    2013-01-01

    Estrogens differentially modulate behavior in the adult female rodent. Voluntary exercise can also impact behavior, often reversing age associated decrements in memory processes. Our research group has published a series of papers reporting a deficit in the acquisition of an operant working memory task, delayed spatial alternation (DSA), following 17β-estradiol treatment to middle-aged ovariectomized (OVX) rats. The current study examined if voluntary exercise could attenuate the 17β-estradiol induced deficits on DSA performance. OVX 12-month old Long- Evans rats were implanted with a Silastic capsule containing 17β-estradiol (10% in cholesterol: low physiological range) or with a blank capsule. A subset of the 17β-estradiol and OVX untreated rats were given free access to a running wheel in their home cage. All rats were tested for 40 sessions on the DSA task. Surprisingly, we found running wheel access to impair initial acquisition of the DSA task in 17β-estradiol treated rats, an effect not seen in OVX untreated rats given running wheel access. This deficit was driven by an increase in perseverative responding on a lever no longer associated with reinforcement. We also report for the first time a 17β-estradiol induced impairment on the DSA task following a long intertrial delay (18-sec), an effect revealed following more extended testing than in our previous studies (15 additional sessions). Overall, running wheel access increased initial error rate on the DSA task in 17β-estradiol treated middle-aged OVX rats, and failed to prevent the 17β-estradiol induced deficits in performance of the operant DSA task in later testing sessions. PMID:24013039

  20. Automated carbon dioxide digital angiography for lower-limb arterial disease evaluation: safety assessment and comparison with standard iodinated contrast media angiography.

    PubMed

    Scalise, Filippo; Novelli, Eugenio; Auguadro, Carla; Casali, Valentina; Manfredi, Mariella; Zannoli, Romano

    2015-01-01

    Carbon dioxide (CO2) has been validated as a contrast agent in a large series of studies. A particular advantages of CO2 over iodinated contrast medium (ICM) is the absence of nephrotoxicity and allergic reactions. One of the limitations of CO2 angiography is the difficulty of CO2 manual injection due to its compressibility. The manual gas injection does not permit optimal control of the gas output. Development of an automated CO2 injector has overcome these problems. This study compares the feasibility, safety, and diagnostic accuracy of automated CO2 digital subtraction angiography (DSA) in comparison with ICM-DSA in the evaluation of critical limb ischemic (CLI) patients. We performed DSA with both CO2 and ICM on 40 consecutive CLI patients and directly compared the two techniques. Sixteen females and 24 males participated in the study (mean age, 71.7 years). We assessed the diagnostic accuracy of CO2 in identifying arterial stenosis in the lower limb, with ICM-DSA used as the gold standard. The overall diagnostic accuracy of CO2-DSA was 96.9% (sensitivity, 99.0%; specificity, 96.1%; positive predictive value, 91.1%; negative predictive value, 99.6%). Tolerable minor symptoms occurred in 3 patients. No allergic reactions or significant decline in renal function were observed in patients receiving the CO2 injection. Carbon dioxide DSA is a valuable and safe alternative to traditional ICM-DSA for evaluating CLI patients. This modality should be considered as the standard choice for CLI patients undergoing angiographic evaluation who are known to have renal insufficiency or contrast allergy.

  1. Stenosis detection in native hemodialysis fistulas with MDCT angiography.

    PubMed

    Heye, Sam; Maleux, Geert; Claes, Kathleen; Kuypers, Dirk; Oyen, Raymond

    2009-04-01

    The objective of our study was to assess the diagnostic value of 64-MDCT angiography in the evaluation of failing hemodialysis arteriovenous fistulas (AVFs) in comparison with conventional digital subtraction angiography (DSA). Thirty-six patients (22 men; mean age +/- SD, 65 +/- 15 years) with hemodialysis fistula dysfunction underwent MDCT angiography before DSA. Linear weighted kappa was used to calculate interobserver agreement for stenosis for both MDCT angiography and DSA on a 5-point scale. Accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the detection of >/= 50% stenosis or occlusion on MDCT angiography was calculated using DSA as the standard of reference. Wilcoxon's signed rank test and Mann-Whitney U test were used to compare differences in image quality between MDCT angiography and DSA and between MDCT angiography with the patient's arm stretched overhead or alongside the body, respectively. Interobserver agreement for detecting stenosis was excellent for both DSA (kappa = 0.86; 95% CI, 0.81-0.91) and MDCT angiography (kappa = 0.82; 95% CI, 0.77-0.87). Accuracy, sensitivity, specificity, PPV, and NPV of MDCT angiography for detecting >/= 50% stenosis or occlusion was 92.0% (95% CI, 86.8-95.3%), 90.2% (77.8-96.3%), 92.8% (85.9-96.6%), 85.2% (72.3-92.9%), and 95.4% (89.0-98.3%), respectively. No significant difference in image quality was seen between MDCT angiography and DSA (p = 0.3008) or between MDCT angiography with the patient's arm stretched overhead or alongside the body (p = 0.2912). MDCT angiography is a reproducible and reliable imaging technique for detection of >/= 50% stenosis or occlusion in dysfunctional hemodialysis fistulas.

  2. Magnetic resonance imaging of pseudotumors of the craniovertebral junction in long-term hemodialysis patients.

    PubMed

    Maruyama, H; Tanizawa, T; Uchiyama, S; Higuchi, T; Ei, K; Oda, M; Ei, I; Oya, M; Kishimoto, H; Saito, T; Miyamura, S; Takano, Y; Hasegawa, S; Kawada, K; Ueki, K; Iwafuchi, Y; Arakawa, M

    1999-01-01

    Pseudotumors of the craniovertebral junction (PTCVJ) are observed in long-term hemodialysis (HD) patients. There are neither criteria for diagnosis nor guidelines for screening. We attempted to determine magnetic resonance imaging (MRI) findings that could be used to detect PTCVJ, to determine the prevalence of PTCVJ, and to evaluate whether destructive spondyloarthropathy (DSA) might be a yardstick for selection of patients for MRI examination for PTCVJ. MRI were examined in 19 DSA patients (8 males, 11 females, age 61.4 +/- 7.3 years, HD duration 17.0 +/- 4.4 years) and in 20 sex-, age-, and HD-duration-matched non-DSA patients (9 males, 11 females, age 57.5 +/- 6.6 years, HD duration 17.7 +/- 4.9 years). We evaluated MRI characteristics of PTCVJ according those which occur due to rheumatoid arthritis. PTCVJ were characterized as follows: disappearance of fat pads in the upper region (supradental PTCVJ), intensity change of the 'predental triangle' in the anterior region (predental PTCVJ), and thickening of cruciform ligaments (retrodental PTCVJ). The prevalence of PTCVJ among patients undergoing HD more than 10 years was high (26 out of 39; 66.7%). The prevalence of PTCVJ was not different between DSA and non-DSA groups. We verified that the above MRI findings might be helpful in the detection of PTCVJ. These findings were observed frequently and independently also in patients with DSA. Copyright 1999 S. Karger AG, Basel

  3. Antioxidant effects of water- and lipid-soluble nitroxide radicals in liposomes.

    PubMed

    Cimato, Alejandra N; Piehl, Lidia L; Facorro, Graciela B; Torti, Horacio B; Hager, Alfredo A

    2004-12-15

    Liposomes are today useful tools in different fields of science and technology. A lack of stability due to lipid peroxidation is the main problem in the extension of the use of these formulations. Recent investigative works have reported the protective effects of stable nitroxide radicals against oxidative processes in different media and under different stress conditions. Our group has focused its attention on the natural aging of liposomes and the protection provided by the water- and lipid-soluble nitroxide radicals 2,2,6,6-tetramethylpiperdine-1-oxyl (TEMPO) and doxylstearic acids (5-DSA, 12-DSA, and 16-DSA), respectively. Unilamellar liposomes were incubated under air atmosphere at 37 degrees C, both in the absence and in the presence of these radicals. Conjugated dienes, lipid hydroperoxides, TBARS, membrane fluidity, and nitroxide ESR signal intensity were followed as a function of time. Our results demonstrated that doxylstearic acids were more efficient than TEMPO in retarding lipid peroxidation at all the concentrations tested. The inhibition percentages, depending on the total nitroxide concentration, were not proportional to the lipid-water partition coefficient. Furthermore, time-course ESR signals showed a slower decrease for doxylstearic acids than for TEMPO. No significant differences were found among 5-DSA, 12-DSA, and 16-DSA. We concluded that the nitroxide radical efficiency as antioxidant directly depends on both nitroxide concentration and lipophilicity.

  4. Dynamic strain-aging effect on fracture toughness of vessel steels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, S.S.; Kim, I.S.

    1992-03-01

    In this paper the effect of dynamic strain aging (DSA) on fracture is investigated on the quenched and tempered specimens of American Society of Mechanical Engineers (ASME) standard SA508 class 3 nuclear pressure vessel steel. Serrated flow by DSA is observed between 180 and 340{degrees}C at a tensile strain rate of 2.08 {times} 10{sup {minus}4}/s and 1.25 {times} 10{sup {minus}3}/s. The DSA causes a sharp rise in the ultimate tensile strength and a marked decrease in ductility. The DSA range shifts to higher temperatures with increased strain rates. The temperature and strain rate dependence of the onset of serrations yieldsmore » an activation energy of 16.2 kcal/mol, which suggests that the process is controlled by interstitial diffusion of carbon and nitrogen in ferrite. The J{sub i} value obtained from the direct current potential drop (DCPD) method, for true crack initiation, is lowered by DSA. The drop in J{sub i} at elevated temperatures may be because of the interaction of the interstitial impurities with dislocations at the crack front.« less

  5. Comparison between digital subtraction angiography and magnetic resonance angiography in investigation of nonlacunar ischemic stroke in young patients: preliminary results.

    PubMed

    Conforto, Adriana Bastos; Fregni, Felipe; Puglia, Paulo; Leite, Claudia da Costa; Yamamoto, Fabio Iuji; Coracini, Karen F; Scaff, Milberto

    2006-06-01

    We preliminarily investigated the relevance of performing digital subtraction angiography (DSA) in addition to magnetic resonance angiography (MRA) in definition of ischemic stroke etiology in young patients. DSAs and MRAs from 17 young patients with nonlacunar ischemic stroke were blindly analyzed and their impact on stroke management was evaluated. Etiologies were the same considering results of either DSA or MRA in 12/17 cases. In 15/17 patients no changes would have been made in treatment, regardless of the modality of angiography considered. These preliminary results suggest that DSA may be redundant in two thirds of ischemic strokes in young patients. Further larger prospective studies are necessary to determine indications of DSA in this age group.

  6. CrossLink: a novel method for cross-condition classification of cancer subtypes.

    PubMed

    Ma, Chifeng; Sastry, Konduru S; Flore, Mario; Gehani, Salah; Al-Bozom, Issam; Feng, Yusheng; Serpedin, Erchin; Chouchane, Lotfi; Chen, Yidong; Huang, Yufei

    2016-08-22

    We considered the prediction of cancer classes (e.g. subtypes) using patient gene expression profiles that contain both systematic and condition-specific biases when compared with the training reference dataset. The conventional normalization-based approaches cannot guarantee that the gene signatures in the reference and prediction datasets always have the same distribution for all different conditions as the class-specific gene signatures change with the condition. Therefore, the trained classifier would work well under one condition but not under another. To address the problem of current normalization approaches, we propose a novel algorithm called CrossLink (CL). CL recognizes that there is no universal, condition-independent normalization mapping of signatures. In contrast, it exploits the fact that the signature is unique to its associated class under any condition and thus employs an unsupervised clustering algorithm to discover this unique signature. We assessed the performance of CL for cross-condition predictions of PAM50 subtypes of breast cancer by using a simulated dataset modeled after TCGA BRCA tumor samples with a cross-validation scheme, and datasets with known and unknown PAM50 classification. CL achieved prediction accuracy >73 %, highest among other methods we evaluated. We also applied the algorithm to a set of breast cancer tumors derived from Arabic population to assign a PAM50 classification to each tumor based on their gene expression profiles. A novel algorithm CrossLink for cross-condition prediction of cancer classes was proposed. In all test datasets, CL showed robust and consistent improvement in prediction performance over other state-of-the-art normalization and classification algorithms.

  7. [2011 Shanghai customer satisfaction report of DSA/X-ray equipment's after-service].

    PubMed

    Li, Bin; Qian, Jianguo; Cao, Shaoping; Zheng, Yunxin; Xu, Zitian; Wang, Lijun

    2012-11-01

    To improve the manufacturer's medical equipment after-sale service, the fifth Shanghai zone customer satisfaction survey was launched by the end of 2011. The DSA/X-ray equipment was setup as an independent category for the first time. From the survey we can show that the DSA/X-ray equipment's CSI is higher than last year, the customer satisfaction scores of preventive maintenance and service contract are lower than others, and CSI of local brand is lower than imported brand.

  8. Three Dimensional Assembly in Directed Self-assembly of Block Copolymers

    DOE PAGES

    Segal-Peretz, Tamar; Zhou, Chun; Ren, Jiaxing; ...

    2016-09-02

    The three-dimensional assembly of poly (styrene-b-methyl methacrylate) (PS-b-PMMA) in chemoepitaxy and graphoepitaxy directed self-assembly (DSA) was investigated using scanning transmission electron microscopy (STEM) tomography. The tomographic characterization revealed hidden morphologies and defects at the BCP- chemical pattern interface in lamellar DSA, and probed the formation of cylinders at the bottom of cylindrical DSA for contact hole shrink. Lastly, future work will include control over 3D assembly in sub-10 nm processes.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larsen, E.W.

    A class of Projected Discrete-Ordinates (PDO) methods is described for obtaining iterative solutions of discrete-ordinates problems with convergence rates comparable to those observed using Diffusion Synthetic Acceleration (DSA). The spatially discretized PDO solutions are generally not equal to the DSA solutions, but unlike DSA, which requires great care in the use of spatial discretizations to preserve stability, the PDO solutions remain stable and rapidly convergent with essentially arbitrary spatial discretizations. Numerical results are presented which illustrate the rapid convergence and the accuracy of solutions obtained using PDO methods with commonplace differencing methods.

  10. Dynamic fair node spectrum allocation for ad hoc networks using random matrices

    NASA Astrophysics Data System (ADS)

    Rahmes, Mark; Lemieux, George; Chester, Dave; Sonnenberg, Jerry

    2015-05-01

    Dynamic Spectrum Access (DSA) is widely seen as a solution to the problem of limited spectrum, because of its ability to adapt the operating frequency of a radio. Mobile Ad Hoc Networks (MANETs) can extend high-capacity mobile communications over large areas where fixed and tethered-mobile systems are not available. In one use case with high potential impact, cognitive radio employs spectrum sensing to facilitate the identification of allocated frequencies not currently accessed by their primary users. Primary users own the rights to radiate at a specific frequency and geographic location, while secondary users opportunistically attempt to radiate at a specific frequency when the primary user is not using it. We populate a spatial radio environment map (REM) database with known information that can be leveraged in an ad hoc network to facilitate fair path use of the DSA-discovered links. Utilization of high-resolution geospatial data layers in RF propagation analysis is directly applicable. Random matrix theory (RMT) is useful in simulating network layer usage in nodes by a Wishart adjacency matrix. We use the Dijkstra algorithm for discovering ad hoc network node connection patterns. We present a method for analysts to dynamically allocate node-node path and link resources using fair division. User allocation of limited resources as a function of time must be dynamic and based on system fairness policies. The context of fair means that first available request for an asset is not envied as long as it is not yet allocated or tasked in order to prevent cycling of the system. This solution may also save money by offering a Pareto efficient repeatable process. We use a water fill queue algorithm to include Shapley value marginal contributions for allocation.

  11. Contrast-Enhanced and Time-of-Flight MRA at 3T Compared with DSA for the Follow-Up of Intracranial Aneurysms Treated with the WEB Device.

    PubMed

    Timsit, C; Soize, S; Benaissa, A; Portefaix, C; Gauvrit, J-Y; Pierot, L

    2016-09-01

    Imaging follow-up at 3T of intracranial aneurysms treated with the WEB Device has not been evaluated yet. Our aim was to assess the diagnostic accuracy of 3D-time-of-flight MRA and contrast-enhanced MRA at 3T against DSA, as the criterion standard, for the follow-up of aneurysms treated with the Woven EndoBridge (WEB) system. From June 2011 to December 2014, patients treated with the WEB in our institution, then followed for ≥6 months after treatment by MRA at 3T (3D-TOF-MRA and contrast-enhanced MRA) and DSA within 48 hours were included. Aneurysm occlusion was assessed with a simplified 2-grade scale (adequate occlusion [total occlusion + neck remnant] versus aneurysm remnant). Interobserver and intermodality agreement was evaluated by calculating the linear weighted κ. MRA test characteristics and predictive values were calculated from a 2 × 2 contingency table, by using DSA data as the standard of reference. Twenty-six patients with 26 WEB-treated aneurysms were included. The interobserver reproducibility was good with DSA (κ = 0.71) and contrast-enhanced-MRA (κ = 0.65) compared with moderate with 3D-TOF-MRA (κ = 0.47). Intermodality agreement with DSA was fair with both contrast-enhanced MRA (κ = 0.36) and 3D-TOF-MRA (κ = 0.36) for the evaluation of total occlusion. For aneurysm remnant detection, the prevalence was low (15%), on the basis of DSA, and both MRA techniques showed low sensitivity (25%), high specificity (100%), very good positive predictive value (100%), and very good negative predictive value (88%). Despite acceptable interobserver reproducibility and predictive values, the low sensitivity of contrast-enhanced MRA and 3D-TOF-MRA for aneurysm remnant detection suggests that MRA is a useful screening procedure for WEB-treated aneurysms, but similar to stents and flow diverters, DSA remains the criterion standard for follow-up. © 2016 by American Journal of Neuroradiology.

  12. DSA-WDS Common Requirements: Developing a New Core Data Repository Certification

    NASA Astrophysics Data System (ADS)

    Minster, J. B. H.; Edmunds, R.; L'Hours, H.; Mokrane, M.; Rickards, L.

    2016-12-01

    The Data Seal of Approval (DSA) and the International Council for Science - World Data System (ICSU-WDS) have both developed minimally intensive core certification standards whereby digital repositories supply evidence that they are trustworthy and have a long-term outlook. Both DSA and WDS applicants have found core certification to be beneficial: building stakeholder confidence, enhancing the repository's reputation, and demonstrating that it is following good practices; as well as stimulating the repository to focus on processes and procedures, thereby achieving ever higher levels of professionalism over time.The DSA and WDS core certifications evolved independently serving initially different communities but both initiatives are multidisciplinary with catalogues of criteria and review procedures based on the same principles. Hence, to realize efficiencies, simplify assessment options, stimulate more certifications, and increase impact on the community, the Repository Audit and Certification DSA-WDS Partnership Working Group (WG) was established under the umbrella of the Research Data Alliance (RDA). The WG conducted a side-by-side analysis of both frameworks to unify the wording and criteria, ultimately leading to a harmonized Catalogue of Common Requirements for core certification of repositories—as well as a set of Common Procedures for their assessment.This presentation will focus on the collaborative effort by DSA and WDS to establish (1) a testbed comprising DSA and WDS certified data repositories to validate both the new Catalogue and Procedures, and (2) a joint Certification Board towards their practical implementation. We will describe:• The purpose and methodology of the testbed, including selection of repositories to be assessed against the common standard.• The results of the testbed, with an in-depth look at some of the comments received and issues highlighted.• General insights gained from evaluating the testbed results, the subsequent changes to the Common Requirements and Procedures, and an assessment of the success of these enhancements.• Steps by the two organizations to integrate the Common Certification into their tools and systems. In particular, the creation of Terms of Reference for the nascent DSA-WDS Certification Board.

  13. Racial differences in the development of de-novo donor-specific antibodies and treated antibody-mediated rejection after heart transplantation.

    PubMed

    Cole, Robert Townsend; Gandhi, Jonathan; Bray, Robert A; Gebel, Howard M; Yin, Michael; Shekiladze, Nikolaz; Young, An; Grant, Aubrey; Mahoney, Ian; Laskar, S Raja; Gupta, Divya; Bhatt, Kunal; Book, Wendy; Smith, Andrew; Nguyen, Duc; Vega, J David; Morris, Alanna A

    2018-04-01

    Despite improvements in outcomes after heart transplantation, black recipients have worse survival compared with non-black recipients. The source of such disparate outcomes remains largely unknown. We hypothesize that a propensity to generate de-novo donor-specific antibodies (dnDSA) and subsequent antibody-mediated rejection (AMR) may account for racial differences in sub-optimal outcomes after heart transplant. In this study we aimed to determine the role of dnDSA and AMR in racial disparities in post-transplant outcomes. This study was a single-center, retrospective analysis of 137 heart transplant recipients (81% male, 48% black) discharged from Emory University Hospital. Patients were classified as black vs non-black for the purpose of our analysis. Kaplan-Meier and Cox regression analyses were used to evaluate the association between race and selected outcomes. The primary outcome was the development of dnDSA. Secondary outcomes included treated AMR and a composite of all-cause graft dysfunction or death. After 3.7 years of follow-up, 39 (28.5%) patients developed dnDSA and 19 (13.8%) were treated for AMR. In multivariable models, black race was associated with a higher risk of developing dnDSA (hazard ratio [HR] 3.65, 95% confidence interval [CI] 1.54 to 8.65, p = 0.003) and a higher risk of treated AMR (HR 4.86, 95% CI 1.26 to 18.72, p = 0.021) compared with non-black race. Black race was also associated with a higher risk of all-cause graft dysfunction or death in univariate analyses (HR 2.10, 95% CI 1.02 to 4.30, p = 0.044). However, in a multivariable model incorporating dnDSA, black race was no longer a significant risk factor. Only dnDSA development was significantly associated with all-cause graft dysfunction or death (HR 4.85, 95% CI 1.89 to 12.44, p = 0.001). Black transplant recipients are at higher risk for the development of dnDSA and treated AMR, which may account for racial disparities in outcomes after heart transplantation. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  14. Glint-induced false alarm reduction in signature adaptive target detection

    NASA Astrophysics Data System (ADS)

    Crosby, Frank J.

    2002-07-01

    The signal adaptive target detection algorithm developed by Crosby and Riley uses target geometry to discern anomalies in local backgrounds. Detection is not restricted based on specific target signatures. The robustness of the algorithm is limited by an increased false alarm potential. The base algorithm is extended to eliminate one common source of false alarms in a littoral environment. This common source is glint reflected on the surface of water. The spectral and spatial transience of glint prevent straightforward characterization and complicate exclusion. However, the statistical basis of the detection algorithm and its inherent computations allow for glint discernment and the removal of its influence.

  15. Doppler-based motion compensation algorithm for focusing the signature of a rotorcraft.

    PubMed

    Goldman, Geoffrey H

    2013-02-01

    A computationally efficient algorithm was developed and tested to compensate for the effects of motion on the acoustic signature of a rotorcraft. For target signatures with large spectral peaks that vary slowly in amplitude and have near constant frequency, the time-varying Doppler shift can be tracked and then removed from the data. The algorithm can be used to preprocess data for classification, tracking, and nulling algorithms. The algorithm was tested on rotorcraft data. The average instantaneous frequency of the first harmonic of a rotorcraft was tracked with a fixed-lag smoother. Then, state space estimates of the frequency were used to calculate a time warping that removed the effect of a time-varying Doppler shift from the data. The algorithm was evaluated by analyzing the increase in the amplitude of the harmonics in the spectrum of a rotorcraft. The results depended upon the frequency of the harmonics and the processing interval duration. Under good conditions, the results for the fundamental frequency of the target (~11 Hz) almost achieved an estimated upper bound. The results for higher frequency harmonics had larger increases in the amplitude of the peaks, but significantly lower than the estimated upper bounds.

  16. 7 CFR 766.51 - General.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... PROGRAMS DIRECT LOAN SERVICING-SPECIAL Disaster Set-Aside § 766.51 General. (a) DSA is available to borrowers with program loans who suffered losses as a result of a natural disaster. (b) DSA is not intended...

  17. 7 CFR 766.51 - General.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... PROGRAMS DIRECT LOAN SERVICING-SPECIAL Disaster Set-Aside § 766.51 General. (a) DSA is available to borrowers with program loans who suffered losses as a result of a natural disaster. (b) DSA is not intended...

  18. 7 CFR 766.51 - General.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... PROGRAMS DIRECT LOAN SERVICING-SPECIAL Disaster Set-Aside § 766.51 General. (a) DSA is available to borrowers with program loans who suffered losses as a result of a natural disaster. (b) DSA is not intended...

  19. 7 CFR 766.51 - General.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... PROGRAMS DIRECT LOAN SERVICING-SPECIAL Disaster Set-Aside § 766.51 General. (a) DSA is available to borrowers with program loans who suffered losses as a result of a natural disaster. (b) DSA is not intended...

  20. 7 CFR 766.51 - General.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... PROGRAMS DIRECT LOAN SERVICING-SPECIAL Disaster Set-Aside § 766.51 General. (a) DSA is available to borrowers with program loans who suffered losses as a result of a natural disaster. (b) DSA is not intended...

  1. Myocardial ischemia during intravenous DSA in patients with cardiac disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hesselink, J.R.; Hayman, L.A.; Chung, K.J.

    1984-12-01

    A prospective study was performed for 48 patients who had histories of angina and were referred for digital subtraction angiography (DSA). Cardiac disease was graded according to the American Heart Association (AHA) functional classification system. Each patient received 2-5 injections of 40-ml diatrizoate meglumine and diatrizoate sodium at 15 ml per second in the superior vena cava. Of the 28 patients in functional Classes I or II, 11% had angina and 32% had definite ischemic ECG changes after the DSA injections. Of the patients in functional Class III 63% had angina, and 58% had definite ischemic ECG changes after themore » injections. These observed cardiac effects following bolus injections of hypertonic ionic contrast media indicate that special precautions are necessary when performing intravenous DSA examinations on this group of high risk patients.« less

  2. Antibodies against toluene diisocyanate protein conjugates. Three methods of measurement.

    PubMed

    Patterson, R; Harris, K E; Zeiss, C R

    1983-12-01

    With the use of canine antisera against toluene diisocyanate (TDI)-dog serum albumin (DSA), techniques for measuring antibody against TDI-DSA were evaluated. The use of an ammonium sulfate precipitation assay showed suggestive evidence of antibody binding but high levels of TDI-DSA precipitation in the absence of antibody limit any usefulness of this technique. Double-antibody co-precipitation techniques will measure total antibody or Ig class antibody against 125I-TDI-DSA. These techniques are quantitative. The polystyrene tube radioimmunoassay is a highly sensitive method of detecting and quantitatively estimating IgG antibody. The enzyme linked immunosorbent assay is a rapidly adaptable method for the quantitative estimation of IgG, IgA, and IgM against TDI-homologous proteins. All these techniques were compared and results are demonstrated by using the same serum sample for analysis.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wehrschuetz, M., E-mail: martin.wehrschuetz@klinikum-graz.at; Aschauer, M.; Portugaller, H.

    The purpose of this study was to assess interobserver variability and accuracy in the evaluation of renal artery stenosis (RAS) with gadolinium-enhanced MR angiography (MRA) and digital subtraction angiography (DSA) in patients with hypertension. The authors found that source images are more accurate than maximum intensity projection (MIP) for depicting renal artery stenosis. Two independent radiologists reviewed MRA and DSA from 38 patients with hypertension. Studies were postprocessed to display images in MIP and source images. DSA was the standard for comparison in each patient. For each main renal artery, percentage stenosis was estimated for any stenosis detected by themore » two radiologists. To calculate sensitivity, specificity and accuracy, MRA studies and stenoses were categorized as normal, mild (1-39%), moderate (40-69%) or severe ({>=}70%), or occluded. DSA stenosis estimates of 70% or greater were considered hemodynamically significant. Analysis of variance demonstrated that MIP estimates of stenosis were greater than source image estimates for both readers. Differences in estimates for MIP versus DSA reached significance in one reader. The interobserver variance for MIP, source images and DSA was excellent (0.80< {kappa}{<=} 0.90). The specificity of source images was high (97%) but less for MIP (87%); average accuracy was 92% for MIP and 98% for source images. In this study, source images are significantly more accurate than MIP images in one reader with a similar trend was observed in the second reader. The interobserver variability was excellent. When renal artery stenosis is a consideration, high accuracy can only be obtained when source images are examined.« less

  4. Routine Use of Three-Dimensional Contrast-Enhanced Moving-Table MR Angiography in Patients with Peripheral Arterial Occlusive Disease: Comparison with Selective Digital Subtraction Angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deutschmann, Hannes A.; Schoellnast, Helmut; Portugaller, Horst R.

    2006-10-15

    Purpose. To compare the diagnostic accuracy of contrast-enhanced (CE) three-dimensional (3D) moving-table magnetic resonance (MR) angiography with that of selective digital subtraction angiography (DSA) for routine clinical investigation in patients with peripheral arterial occlusive disease. Methods. Thirty-eight patients underwent CE 3D moving-table MR angiography of the pelvic and peripheral arteries. A commercially available large-field-of-view adapter and a dedicated peripheral vascular phased-array coil were used. MR angiograms were evaluated for grade of arterial stenosis, diagnostic quality, and presence of artifacts. MR imaging results for each patient were compared with those of selective DSA. Results. Two hundred and twenty-six arterial segments inmore » 38 patients were evaluated by both selective DSA and MR angiography. No complications related to MR angiography were observed. There was agreement in stenosis classification in 204 (90.3%) segments; MR angiography overgraded 16 (7%) segments and undergraded 6 (2.7%) segments. Compared with selective DSA, MR angiography provided high sensitivity and specificity and excellent interobserver agreement for detection of severe stenosis (97% and 95%, {kappa} = 0.9 {+-} 0.03) and moderate stenosis (96.5% and 94.3%, {kappa} = 0.9 {+-} 0.03). Conclusion. Compared with selective DSA, moving-table MR angiography proved to be an accurate, noninvasive method for evaluation of peripheral arterial occlusive disease and may thus serve as an alternative to DSA in clinical routine.« less

  5. Mechanism of Dynamic Strain Aging in a Niobium-Stabilized Austenitic Stainless Steel

    NASA Astrophysics Data System (ADS)

    Zhou, Hongwei; Bai, Fengmei; Yang, Lei; Wei, Hailian; Chen, Yan; Peng, Guosheng; He, Yizhu

    2018-04-01

    Dynamic strain aging (DSA) behavior of a niobium (Nb)-stabilized austenitic stainless steel (TP347H) was studied from room temperature (RT) to 973 K via tensile testing, transmission electron microscopy (TEM), and internal friction (IF) measurements. The DSA effect is nearly negligible from 573 K to 673 K, and it becomes significant at temperatures between 773 K and 873 K with strain rates of 3 × 10-3 s-1, 8 × 10-4 s-1, and 8 × 10-5 s-1, respectively. The results indicate that a dislocation planar slip is dominant in the strong DSA regime. The Snoek-like peak located at 625 K is highly sensitive to the diffusion of free carbon (C) atoms in solid solution. C-Nb octahedrons are formed by C chemical affinity to substitutional Nb solute atoms. Octahedron structure is very stable and captures most free C atoms and inhibits DSA at low tensile test temperatures of 573 K to 673 K. At high test temperatures in the range from 773 K to 873 K, C-Nb octahedrons break up and release free C and Nb atoms, resulting in the stronger Snoek-like peak. The interaction between C atoms and dislocations is responsible for DSA at low temperatures ranging from 573 K to 673 K. At higher temperature of 773 K to 873 K, the Cr and Nb atoms lock the dislocations, and this formation contributes to DSA.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reekers, Jim A., E-mail: j.a.reekers@amc.uva.nl; Koelemay, Mark J. W., E-mail: m.j.koelemaij@amc.uva.nl; Marquering, Henk A., E-mail: h.a.marquering@amc.uva.nl

    PurposeTo report on the first clinical experience with perfusion angiography (PA) of the foot in patients with chronic critical limb ischemia.Materials and MethodsPA is a post-processing software algorithm and no extra digital subtraction angiography (DSA) has to be performed for this analysis. The data used to test the feasibility of PA were obtained from a consecutive group of 89 patients with CLI who were treated with standard below the knee angioplasty and 12 separate patients who were not suitable for endovascular revascularization.ResultsMotion artifacts in the dataset of the DSA made post-procedural analysis impossible in 10 % intervention. In the majority ofmore » patients (59/68) PA showed an increase in volume flow in the foot after successful angioplasty of the crural vessels. However, in 9/68 patients no increase was seen after successful angioplasty. With the use of a local administered competitive α-adrenergic receptor antagonist, it is also possible to test and quantify the capillary resistance index which is a parameter for the remaining functionality of the microcirculation in CLI patients.ConclusionPA might be used as a new endpoint for lower limb revascularization and can also be used to test the functionality the microcirculation to identify sub-types of patients with CLI. Clinical evaluation and standardization of PA is mandatory before introduction in daily practice.« less

  7. Robotic digital subtraction angiography systems within the hybrid operating room.

    PubMed

    Murayama, Yuichi; Irie, Koreaki; Saguchi, Takayuki; Ishibashi, Toshihiro; Ebara, Masaki; Nagashima, Hiroyasu; Isoshima, Akira; Arakawa, Hideki; Takao, Hiroyuki; Ohashi, Hiroki; Joki, Tatsuhiro; Kato, Masataka; Tani, Satoshi; Ikeuchi, Satoshi; Abe, Toshiaki

    2011-05-01

    Fully equipped high-end digital subtraction angiography (DSA) within the operating room (OR) environment has emerged as a new trend in the fields of neurosurgery and vascular surgery. To describe initial clinical experience with a robotic DSA system in the hybrid OR. A newly designed robotic DSA system (Artis zeego; Siemens AG, Forchheim, Germany) was installed in the hybrid OR. The system consists of a multiaxis robotic C arm and surgical OR table. In addition to conventional neuroendovascular procedures, the system was used as an intraoperative imaging tool for various neurosurgical procedures such as aneurysm clipping and spine instrumentation. Five hundred one neurosurgical procedures were successfully conducted in the hybrid OR with the robotic DSA. During surgical procedures such as aneurysm clipping and arteriovenous fistula treatment, intraoperative 2-/3-dimensional angiography and C-arm-based computed tomographic images (DynaCT) were easily performed without moving the OR table. Newly developed virtual navigation software (syngo iGuide; Siemens AG) can be used in frameless navigation and in access to deep-seated intracranial lesions or needle placement. This newly developed robotic DSA system provides safe and precise treatment in the fields of endovascular treatment and neurosurgery.

  8. Alloantibody and Autoantibody Monitoring Predicts Islet Transplantation Outcome in Human Type 1 Diabetes

    PubMed Central

    Piemonti, Lorenzo; Everly, Matthew J.; Maffi, Paola; Scavini, Marina; Poli, Francesca; Nano, Rita; Cardillo, Massimo; Melzi, Raffaella; Mercalli, Alessia; Sordi, Valeria; Lampasona, Vito; Espadas de Arias, Alejandro; Scalamogna, Mario; Bosi, Emanuele; Bonifacio, Ezio; Secchi, Antonio; Terasaki, Paul I.

    2013-01-01

    Long-term clinical outcome of islet transplantation is hampered by the rejection and recurrence of autoimmunity. Accurate monitoring may allow for early detection and treatment of these potentially compromising immune events. Islet transplant outcome was analyzed in 59 consecutive pancreatic islet recipients in whom baseline and de novo posttransplant autoantibodies (GAD antibody, insulinoma-associated protein 2 antigen, zinc transporter type 8 antigen) and donor-specific alloantibodies (DSA) were quantified. Thirty-nine recipients (66%) showed DSA or autoantibody increases (de novo expression or titer increase) after islet transplantation. Recipients who had a posttransplant antibody increase showed similar initial performance but significantly lower graft survival than patients without an increase (islet autoantibodies P < 0.001, DSA P < 0.001). Posttransplant DSA or autoantibody increases were associated with HLA-DR mismatches (P = 0.008), induction with antithymocyte globulin (P = 0.0001), and pretransplant panel reactive alloantibody >15% in either class I or class II (P = 0.024) as independent risk factors and with rapamycin as protective (P = 0.006) against antibody increases. DSA or autoantibody increases after islet transplantation are important prognostic markers, and their identification could potentially lead to improved islet cell transplant outcomes. PMID:23274902

  9. Synergistic integration of sonochemical and electrochemical disinfection with DSA anodes.

    PubMed

    Cotillas, Salvador; Llanos, Javier; Castro-Ríos, Katherin; Taborda-Ocampo, Gonzalo; Rodrigo, Manuel A; Cañizares, Pablo

    2016-11-01

    This work focuses on the disinfection actual urban wastewater by the combination of ultrasound (US) irradiation and electrodisinfection with Dimensionally Stable Anodes (DSA). First, the inactivation of Escherichia coli (E. coli) during the sonochemical disinfection was studied at increasing ultrasound power. Results showed that it was not possible to achieve a complete disinfection, even at the highest US power (200 W) dosed by the experimental device used. Next, the electrodisinfection with DSA anodes at different current densities was studied, finding that it was necessary a minimum current density of 11.46 A m(-2) to reach the complete disinfection. Finally, an integrated sonoelectrodisinfection process was studied. Results showed a synergistic effect when coupling US irradiation with DSA electrodisinfection, with a synergy coefficient higher than 200% of the disinfection rate attained for the highest US power applied. In this process, hypochlorite and chloramines were identified as the main reagents for the disinfection process (neither chlorate nor perchlorate were detected), and the presence of trihalomethanes was far below acceptable values. Confirming this synergistic effect with DSA anodes opens the door to novel efficient disinfection processes, limiting the occurrence of hazardous disinfection by-products. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Autonomous proximity operations using machine vision for trajectory control and pose estimation

    NASA Technical Reports Server (NTRS)

    Cleghorn, Timothy F.; Sternberg, Stanley R.

    1991-01-01

    A machine vision algorithm was developed which permits guidance control to be maintained during autonomous proximity operations. At present this algorithm exists as a simulation, running upon an 80386 based personal computer, using a ModelMATE CAD package to render the target vehicle. However, the algorithm is sufficiently simple, so that following off-line training on a known target vehicle, it should run in real time with existing vision hardware. The basis of the algorithm is a sequence of single camera images of the target vehicle, upon which radial transforms were performed. Selected points of the resulting radial signatures are fed through a decision tree, to determine whether the signature matches that of the known reference signatures for a particular view of the target. Based upon recognized scenes, the position of the maneuvering vehicle with respect to the target vehicles can be calculated, and adjustments made in the former's trajectory. In addition, the pose and spin rates of the target satellite can be estimated using this method.

  11. A general design strategy for block copolymer directed self-assembly patterning of integrated circuits contact holes using an alphabet approach.

    PubMed

    Yi, He; Bao, Xin-Yu; Tiberio, Richard; Wong, H-S Philip

    2015-02-11

    Directed self-assembly (DSA) is a promising lithography candidate for technology nodes beyond 14 nm. Researchers have shown contact hole patterning for random logic circuits using DSA with small physical templates. This paper introduces an alphabet approach that uses a minimal set of small physical templates to pattern all contacts configurations on integrated circuits. We illustrate, through experiments, a general and scalable template design strategy that links the DSA material properties to the technology node requirements.

  12. Importance of correlation between gene expression levels: application to the type I interferon signature in rheumatoid arthritis.

    PubMed

    Reynier, Frédéric; Petit, Fabien; Paye, Malick; Turrel-Davin, Fanny; Imbert, Pierre-Emmanuel; Hot, Arnaud; Mougin, Bruno; Miossec, Pierre

    2011-01-01

    The analysis of gene expression data shows that many genes display similarity in their expression profiles suggesting some co-regulation. Here, we investigated the co-expression patterns in gene expression data and proposed a correlation-based research method to stratify individuals. Using blood from rheumatoid arthritis (RA) patients, we investigated the gene expression profiles from whole blood using Affymetrix microarray technology. Co-expressed genes were analyzed by a biclustering method, followed by gene ontology analysis of the relevant biclusters. Taking the type I interferon (IFN) pathway as an example, a classification algorithm was developed from the 102 RA patients and extended to 10 systemic lupus erythematosus (SLE) patients and 100 healthy volunteers to further characterize individuals. We developed a correlation-based algorithm referred to as Classification Algorithm Based on a Biological Signature (CABS), an alternative to other approaches focused specifically on the expression levels. This algorithm applied to the expression of 35 IFN-related genes showed that the IFN signature presented a heterogeneous expression between RA, SLE and healthy controls which could reflect the level of global IFN signature activation. Moreover, the monitoring of the IFN-related genes during the anti-TNF treatment identified changes in type I IFN gene activity induced in RA patients. In conclusion, we have proposed an original method to analyze genes sharing an expression pattern and a biological function showing that the activation levels of a biological signature could be characterized by its overall state of correlation.

  13. Extension of moment projection method to the fragmentation process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Shaohua; Yapp, Edward K.Y.; Akroyd, Jethro

    2017-04-15

    The method of moments is a simple but efficient method of solving the population balance equation which describes particle dynamics. Recently, the moment projection method (MPM) was proposed and validated for particle inception, coagulation, growth and, more importantly, shrinkage; here the method is extended to include the fragmentation process. The performance of MPM is tested for 13 different test cases for different fragmentation kernels, fragment distribution functions and initial conditions. Comparisons are made with the quadrature method of moments (QMOM), hybrid method of moments (HMOM) and a high-precision stochastic solution calculated using the established direct simulation algorithm (DSA) and advantagesmore » of MPM are drawn.« less

  14. Diagnostic accuracy of 64-slice multidetector CT angiography for detection of in-stent restenosis of vertebral artery ostium stents: comparison with conventional angiography.

    PubMed

    Lee, Youn Joo; Lim, Yeon Soo; Lim, Hyun Wook; Yoo, Won Jong; Choi, Byung Gil; Kim, Bum Soo

    2014-10-01

    There are very few reports assessing in-stent restenosis (ISR) after vertebral artery ostium (VAO) stents using multidetector computed tomography (MDCT). To compare the diagnostic accuracy of computed tomography angiography (CTA) using 64-slice MDCT with digital subtraction angiography (DSA) for detection of significant ISR after VAO stenting. The study evaluated 57 VAO stents in 57 patients (39 men, 18 women; mean age 64 years [range, 48-90 years]). All stents were scanned with a 64-slice MDCT scanner. Three sets of images were reconstructed with three different convolution kernels. Two observers who were blinded to the results of DSA assessed the diagnostic accuracy of CTA for detecting significant ISR (≥50% diameter narrowing) of VAO stents in comparison with DSA as the reference standard. The sensitivity, specificity, positive and negative predictive values, and accuracy were calculated. Of the 57 stents, 46 (81%) were assessable using CTA, while 11 (19%) were not. No stents with diameters ≤2.75 mm were assessable. DSA revealed 13 cases of significant ISR in all stents. The respective sensitivity, specificity, positive and negative predictive values, and accuracy were 92%, 82%, 60%, 97%, and 84% for all stents. On excluding the 11 non-assessable stents, the respective values were 88%, 95%, 78%, 97%, and 93%. Of the 46 CTA assessable stents, eight significant ISRs were diagnosed on DSA. Seven of eight patients with significant ISR by DSA were diagnosed correctly with CTA. The area under the receiver-operating characteristic curve (AUC) was 0.87 for all stents and 0.91 for assessable stents, indicating good to excellent agreement between CTA and DSA for detecting significant ISR after VAO stenting. Sixty-four-slice MDCT is a promising non-invasive method of assessing stent patency and can exclude significant ISR with high diagnostic values after VAO stenting. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Blunt cerebrovascular injury screening with 64-channel multidetector computed tomography: more slices finally cut it.

    PubMed

    Paulus, Elena M; Fabian, Timothy C; Savage, Stephanie A; Zarzaur, Ben L; Botta, Vandana; Dutton, Wesley; Croce, Martin A

    2014-02-01

    Aggressive screening to diagnose blunt cerebrovascular injury (BCVI) results in early treatment, leading to improved outcomes and reduced stroke rates. While computed tomographic angiography (CTA) has been widely adopted for BCVI screening, evidence of its diagnostic sensitivity is marginal. Previous work from our institution using 32-channel multidetector CTA in 684 patients demonstrated an inadequate sensitivity of 51% (Ann Surg. 2011,253: 444-450). Digital subtraction angiography (DSA) continues to be the reference standard of diagnosis but has significant drawbacks of invasiveness and resource demands. There have been continued advances in CT technology, and this is the first report of an extensive experience with 64-channel multidetector CTA. Patients screened for BCVI using CTA and DSA (reference) at a Level 1 trauma center during the 12-month period ending in May 2012 were identified. Results of CTA and DSA, complications, and strokes were retrospectively reviewed and compared. A total of 594 patients met criteria for BCVI screening and underwent both CTA and DSA. One hundred twenty-eight patients (22% of those screened) had 163 injured vessels: 99 (61%) carotid artery injuries and 64 (39%) vertebral artery injuries. Sixty-four-channel CTA demonstrated an overall sensitivity per vessel of 68% and specificity of 92%. The 52 false-negative findings on CTA were composed of 34 carotid artery injuries and 18 vertebral artery injuries; 32 (62%) were Grade I injuries. Overall, positive predictive value was 36.2%, and negative predictive value was 97.5%. Six procedure-related complications (1%) occurred with DSA, including two iatrogenic dissections and one stroke. Sixty-four-channel CTA demonstrated a significantly improved sensitivity of 68% versus the 51% previously reported for the 32-channel CTA (p = 0.0075). Sixty-two percent of the false-negative findings occurred with low-grade injuries. Considering complications, cost, and resource demand associated with DSA, this study suggests that 64-channel CTA may replace DSA as the primary screening tool for BCVI. Diagnostic study, level III.

  16. Comparison of standard- and low-tube voltage 320-detector row volume CT angiography in detection of intracranial aneurysms with digital subtraction angiography as gold standard.

    PubMed

    Sun, Gang; Ding, Juan; Lu, Yang; Li, Min; Li, Li; Li, Guo-ying; Zhang, Xu-ping

    2012-03-01

    The aim of this study was to prospectively assess the effect of low-tube voltage (80 kVp) 320-detector row volume computed tomographic (CT) angiography (L-VCTA) in the detection of intracranial aneurysms, with three-dimensional (3D) spin digital subtraction angiography (DSA) as the gold standard. Forty-eight patients with clinically suspected subarachnoid hemorrhages were divided into two groups. One group underwent L-VCTA and DSA, while the other group underwent conventional-tube voltage (120 kVp) volume CT angiography (C-VCTA) and DSA. Vascular enhancement, image quality, detection accuracy of aneurysms, and radiation dose were compared between the two groups. For objective image quality, the L-VCTA group had higher mean vessel attenuation, correlated with higher image noise and lower signal-to-noise ratio, than the C-VCTA group. For subjective image quality, there were no significant differences between the two groups regarding scores for arterial enhancement, depiction of small arterial detail, interference of venous structures, and overall image quality scores. The mean effective dose for the L-VCTA group was significantly lower than for the C-VCTA group (0.56 ± 0.25 vs 1.84 ± 0.002 mSv), with a reduction of radiation dose of 69.73%. With 3D DSA as the reference standard, the sensitivity, specificity, and accuracy in the L-VCTA and C-VCTA groups were 94.12%, 100%, 94.4% and 100%, 100%, and 100%, respectively. In both groups, there were significant correlations for maximum aneurysm diameter measurements between volume CT angiography and 3D DSA; no statistical difference in the mean maximum diameter of each aneurysm was measured between volume CT angiography and 3D DSA. L-VCTA is helpful in detecting intracranial aneurysms, with results similar to those of 3D DSA, but at a lower radiation dose than C-VCTA. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  17. Timely Antecedent CT or MRI Can Help Predict Hemorrhage Site of Posttreatment Head and Neck Cancer, With Digital Subtraction Angiography Used as the Reference Standard.

    PubMed

    Ku, Yi-Kang; Wong, Yon-Cheong; Fu, Chen-Ju; Tseng, Hsiao-Jung; Wang, Li-Jen; Wang, Chao-Jan; Chin, Shy-Chyi

    2016-04-01

    We investigated the timing of CT and MRI performed before digital subtraction angiography (DSA) in the prediction of hemorrhage sites in patients with head and neck cancers who present with acute oral or neck bleeding after receiving treatment. A total of 123 DSA examinations that evaluated 123 oral or neck bleeding events in 85 patients were analyzed. The last CT or MRI examinations performed within a time frame of 0-337 days before transarterial embolization were reviewed retrospectively, with three findings (pseudoaneurysm, air-containing necrotic tissue, and residual tumor) used to predict hemorrhage sites. DSA findings of pseudoaneurysm or active contrast extravasation were used as a reference standard. The sensitivity of CT and MRI for correctly predicting hemorrhage sites was used to determine the optimal timing of CT or MRI examinations performed before DSA. A total of 8.9% of the DSA examinations (11/123) had equivocal findings but were followed by another bleeding event for which DSA findings were positive. CT or MRI was statistically significantly better at predicting hemorrhage sites in patients with bleeding events associated with nonhypopharyngeal cancers (p = 0.019) than in those with bleeding events associated with hypopharyngeal cancers. The sensitivity of CT or MRI in the prediction of hemorrhage sites was statistically significantly higher for the common carotid artery and the internal carotid artery when CT or MRI was performed less than 30 days before bleeding events occurred. Prediction of hemorrhagic sites was better with the use of CT angiography than with the use of enhanced CT or MRI, although it was not statistically significant. DSA findings can temporarily be equivocal. CT or MRI examinations performed within 30 days of bleeding events can predict the site of hemorrhage. If no CT or MRI findings from the past 30 days are available, we suggest performing emergent CT angiography for the sake of obtaining better arterial detail.

  18. Pattern fidelity improvement of chemo-epitaxy DSA process for high-volume manufacturing

    NASA Astrophysics Data System (ADS)

    Muramatsu, Makoto; Nishi, Takanori; You, Gen; Saito, Yusuke; Ido, Yasuyuki; Ito, Kiyohito; Tobana, Toshikatsu; Hosoya, Masanori; Chen, Weichien; Nakamura, Satoru; Somervell, Mark; Kitano, Takahiro

    2016-03-01

    Directed self-assembly (DSA) is one of the candidates for next generation lithography. Over the past few years, cylindrical and lamellar structures dictated by the block co-polymer (BCP) composition have been investigated for use in patterning contact holes or lines, and, Tokyo Electron Limited (TEL is a registered trademark or a trademark of Tokyo Electron Limited in Japan and /or other countries.) has presented the evaluation results and the advantages of each-1-5. In this report, we will present the latest results regarding the defect reduction work on a model line/space system. Especially it is suggested that the defectivity of the neutral layer has a large impact on the defectivity of the DSA patterns. Also, LER/LWR reduction results will be presented with a focus on the improvements made during the etch transferring the DSA patterns into the underlayer.

  19. All-optical signatures of strong-field QED in the vacuum emission picture

    NASA Astrophysics Data System (ADS)

    Gies, Holger; Karbstein, Felix; Kohlfürst, Christian

    2018-02-01

    We study all-optical signatures of the effective nonlinear couplings among electromagnetic fields in the quantum vacuum, using the collision of two focused high-intensity laser pulses as an example. The experimental signatures of quantum vacuum nonlinearities are encoded in signal photons, whose kinematic and polarization properties differ from the photons constituting the macroscopic laser fields. We implement an efficient numerical algorithm allowing for the theoretical investigation of such signatures in realistic field configurations accessible in experiment. This algorithm is based on a vacuum emission scheme and can readily be adapted to the collision of more laser beams or further involved field configurations. We solve the case of two colliding pulses in full 3 +1 -dimensional spacetime and identify experimental geometries and parameter regimes with improved signal-to-noise ratios.

  20. Formal Methods for Cryptographic Protocol Analysis: Emerging Issues and Trends

    DTIC Science & Technology

    2003-01-01

    signatures , which depend upon the homomor- phic properties of RSA. Other algorithms and data structures, such as Chaum mixes [17], designed for...Communications Security, pages 176–185. ACM, Novem- ber 2001. [17] D. Chaum . Untraceable electronic mail, return addresses and digital signatures ...something like the Diffie- Hellman algorithm, which depends, as a minimum, on the commutative properties of exponentiation, or something like Chaum’s blinded

  1. Signature molecular descriptor : advanced applications.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Visco, Donald Patrick, Jr.

    In this work we report on the development of the Signature Molecular Descriptor (or Signature) for use in the solution of inverse design problems as well as in highthroughput screening applications. The ultimate goal of using Signature is to identify novel and non-intuitive chemical structures with optimal predicted properties for a given application. We demonstrate this in three studies: green solvent design, glucocorticoid receptor ligand design and the design of inhibitors for Factor XIa. In many areas of engineering, compounds are designed and/or modified in incremental ways which rely upon heuristics or institutional knowledge. Often multiple experiments are performed andmore » the optimal compound is identified in this brute-force fashion. Perhaps a traditional chemical scaffold is identified and movement of a substituent group around a ring constitutes the whole of the design process. Also notably, a chemical being evaluated in one area might demonstrate properties very attractive in another area and serendipity was the mechanism for solution. In contrast to such approaches, computer-aided molecular design (CAMD) looks to encompass both experimental and heuristic-based knowledge into a strategy that will design a molecule on a computer to meet a given target. Depending on the algorithm employed, the molecule which is designed might be quite novel (re: no CAS registration number) and/or non-intuitive relative to what is known about the problem at hand. While CAMD is a fairly recent strategy (dating to the early 1980s), it contains a variety of bottlenecks and limitations which have prevented the technique from garnering more attention in the academic, governmental and industrial institutions. A main reason for this is how the molecules are described in the computer. This step can control how models are developed for the properties of interest on a given problem as well as how to go from an output of the algorithm to an actual chemical structure. This report provides details on a technique to describe molecules on a computer, called Signature, as well as the computer-aided molecule design algorithm built around Signature. Two applications are provided of the CAMD algorithm with Signature. The first describes the design of green solvents based on data in the GlaxoSmithKline (GSK) Solvent Selection Guide. The second provides novel non-steroidal glucocorticoid receptor ligands with some optimally predicted properties. In addition to using the CAMD algorithm with Signature, it is demonstrated how to employ Signature in a high-throughput screening study. Here, after classifying both active and inactive inhibitors for the protein Factor XIa using Signature, the model developed is used to screen a large, publicly-available database called PubChem for the most active compounds.« less

  2. Etch challenges for DSA implementation in CMOS via patterning

    NASA Astrophysics Data System (ADS)

    Pimenta Barros, P.; Barnola, S.; Gharbi, A.; Argoud, M.; Servin, I.; Tiron, R.; Chevalier, X.; Navarro, C.; Nicolet, C.; Lapeyre, C.; Monget, C.; Martinez, E.

    2014-03-01

    This paper reports on the etch challenges to overcome for the implementation of PS-b-PMMA block copolymer's Directed Self-Assembly (DSA) in CMOS via patterning level. Our process is based on a graphoepitaxy approach, employing an industrial PS-b-PMMA block copolymer (BCP) from Arkema with a cylindrical morphology. The process consists in the following steps: a) DSA of block copolymers inside guiding patterns, b) PMMA removal, c) brush layer opening and finally d) PS pattern transfer into typical MEOL or BEOL stacks. All results presented here have been performed on the DSA Leti's 300mm pilot line. The first etch challenge to overcome for BCP transfer involves in removing all PMMA selectively to PS block. In our process baseline, an acetic acid treatment is carried out to develop PMMA domains. However, this wet development has shown some limitations in terms of resists compatibility and will not be appropriated for lamellar BCPs. That is why we also investigate the possibility to remove PMMA by only dry etching. In this work the potential of a dry PMMA removal by using CO based chemistries is shown and compared to wet development. The advantages and limitations of each approach are reported. The second crucial step is the etching of brush layer (PS-r-PMMA) through a PS mask. We have optimized this step in order to preserve the PS patterns in terms of CD, holes features and film thickness. Several integrations flow with complex stacks are explored for contact shrinking by DSA. A study of CD uniformity has been addressed to evaluate the capabilities of DSA approach after graphoepitaxy and after etching.

  3. Use of the dye stain assay and ultraviolet light test for assessing vaginal insertion of placebo-filled applicators before and after sex.

    PubMed

    Keller, Marla J; Buckley, Niall; Katzen, Lauren L; Walsh, Jennifer; Friedland, Barbara; Littlefield, Sarah; Lin, Juan; Xue, Xiaonan; Cornelison, Terri; Herold, Betsy C; Einstein, Mark H

    2013-12-01

    Applicator dye staining and ultraviolet (UV) light have been used in trials to measure adherence, but not in the setting of before and after sex gel dosing (BAT-24). This study was designed to determine if semen or presex gel dosing impacts the sensitivity and specificity of a dye stain assay (DSA) for measuring vaginal insertion of placebo-filled applicators with BAT-24 dosing. Healthy monogamous couples received Microlax-type applicators (Tectubes, Åstorp, Sweden) filled with hydroxyethylcelluose placebo gel. Women were instructed to vaginally insert 1 dose of gel before and a second dose after sex and to return applicators within 48 hours after sex. Applicators were stained to detect semen, followed by UV then DSA, and scored by 2 readers. Positive and negative controls were randomly included in applicator batches. Fifteen couples completed the study. Each woman returned at least 6 applicators over a 30-day period. The sensitivity for insertion of postsex applicators was higher for UV (97%) compared with DSA (90%), and the specificity was similar (≥96%). For presex applicators, the sensitivity and specificity were higher for DSA (100%) compared with UV testing (87% sensitivity, 96% specificity). Among returned postsex applicators, 95% tested positive by UV compared with 87% by DSA. Agreement between readers was significantly better on the presex applicators for DSA than for UV, and for postsex readings, agreement was less than half that for UV, although the results were not statistically significant. Applicator tests are feasible for measuring adherence in trials with gel dosing before and after sex.

  4. Evaluation of security algorithms used for security processing on DICOM images

    NASA Astrophysics Data System (ADS)

    Chen, Xiaomeng; Shuai, Jie; Zhang, Jianguo; Huang, H. K.

    2005-04-01

    In this paper, we developed security approach to provide security measures and features in PACS image acquisition and Tele-radiology image transmission. The security processing on medical images was based on public key infrastructure (PKI) and including digital signature and data encryption to achieve the security features of confidentiality, privacy, authenticity, integrity, and non-repudiation. There are many algorithms which can be used in PKI for data encryption and digital signature. In this research, we select several algorithms to perform security processing on different DICOM images in PACS environment, evaluate the security processing performance of these algorithms, and find the relationship between performance with image types, sizes and the implementation methods.

  5. Design Time Optimization for Hardware Watermarking Protection of HDL Designs

    PubMed Central

    Castillo, E.; Morales, D. P.; García, A.; Parrilla, L.; Todorovich, E.; Meyer-Baese, U.

    2015-01-01

    HDL-level design offers important advantages for the application of watermarking to IP cores, but its complexity also requires tools automating these watermarking algorithms. A new tool for signature distribution through combinational logic is proposed in this work. IPP@HDL, a previously proposed high-level watermarking technique, has been employed for evaluating the tool. IPP@HDL relies on spreading the bits of a digital signature at the HDL design level using combinational logic included within the original system. The development of this new tool for the signature distribution has not only extended and eased the applicability of this IPP technique, but it has also improved the signature hosting process itself. Three algorithms were studied in order to develop this automated tool. The selection of a cost function determines the best hosting solutions in terms of area and performance penalties on the IP core to protect. An 1D-DWT core and MD5 and SHA1 digital signatures were used in order to illustrate the benefits of the new tool and its optimization related to the extraction logic resources. Among the proposed algorithms, the alternative based on simulated annealing reduces the additional resources while maintaining an acceptable computation time and also saving designer effort and time. PMID:25861681

  6. Design features of implants for direct skeletal attachment of limb prostheses

    PubMed Central

    Pitkin, M.

    2013-01-01

    In direct skeletal attachment (DSA) of limb prostheses, a construct is implanted into an amputee’s residuum bone and protrudes out of the residuum’s skin. This technology represents an alternative to traditional suspension of prostheses via various socket systems, with clear indications when the sockets cannot be properly fitted. Contemporary DSA was invented in the 1990s, and several implant systems have been introduced since then. The current review is intended to compare the design features of implants for DSA whose use in humans or in animal studies has been reported in the literature. PMID:23554122

  7. Effects of Loading Frequency on Fatigue Behavior, Residual Stress, and Microstructure of Deep-Rolled Stainless Steel AISI 304 at Elevated Temperatures

    NASA Astrophysics Data System (ADS)

    Nikitin, I.; Juijerm, P.

    2018-02-01

    The effects of loading frequency on the fatigue behavior of non-deep-rolled (NDR) and deep-rolled (DR) austenitic stainless steel AISI 304 were systematically clarified at elevated temperatures, especially at temperatures exhibiting the dynamic strain aging (DSA) phenomena. Tension-compression fatigue tests were performed isothermally at temperatures of 573 K and 773 K (300 °C and 500 °C) with different loading frequencies of 5, 0.5, 0.05, and 0.005 Hz. For the DR condition, the residual stresses and work-hardening states will be presented. It was found that DSA would be detected at appropriate temperatures and deformation rates. The cyclic deformation curves and the fatigue lives of the investigated austenitic stainless steel AISI 304 are considerably affected by the DSA, especially on the DR condition having high dislocation densities at the surface and in near-surface regions. In the temperature range of the DSA, residual stresses and work-hardening states of the DR condition seem to be stabilized. The microstructural alterations were investigated by transmission electron microscopy (TEM). At an appropriate temperature with low loading frequency, the plastic deformation mechanism shifted from a wavy slip manner to a planar slip manner in the DSA regimes, whereas the dislocation movements were obstructed.

  8. Representing situation awareness in collaborative systems: a case study in the energy distribution domain.

    PubMed

    Salmon, P M; Stanton, N A; Walker, G H; Jenkins, D; Baber, C; McMaster, R

    2008-03-01

    The concept of distributed situation awareness (DSA) is currently receiving increasing attention from the human factors community. This article investigates DSA in a collaborative real-world industrial setting by discussing the results derived from a recent naturalistic study undertaken within the UK energy distribution domain. The results describe the DSA-related information used by the networks of agents involved in the scenarios analysed, the sharing of this information between the agents and the salience of different information elements used. Thus, the structure, quality and content of each network's DSA is discussed, along with the implications for DSA theory. The findings reinforce the notion that when viewing situation awareness (SA) in collaborative systems, it is useful to focus on the coordinated behaviour of the system itself, rather than on the individual as the unit of analysis and suggest that the findings from such assessments can potentially be used to inform system, procedure and training design. SA is a critical commodity for teams working in industrial systems and systems, procedures and training programmes should be designed to facilitate efficient system SA acquisition and maintenance. This article presents approaches for describing and understanding SA during real-world collaborative tasks, the outputs from which can potentially be used to inform system, training programmes and procedure design.

  9. The costs and effects of contrast-enhanced magnetic resonance angiography and digital substraction angiography on quality of life in patients with peripheral arterial disease.

    PubMed

    Bosma, Jan; Dijksman, Lea M; Lam, Kayan; Wisselink, Willem; van Swijndregt, Alexander D Montauban; Vahl, Anco

    2014-04-01

    Contrast-enhanced magnetic resonance angiography (MRA) and intra-arterial digital subtraction angiography (DSA) both have a high diagnostic performance in the imaging of peripheral arterial occlusive disease (PAOD). However, little is known about the effects of initial, preoperative imaging using MRA or DSA on quality of life (QoL) in relation to costs (cost-utility). To compare cost-utility of treatment strategies using either MRA or DSA as the principal imaging tool, related to QoL, in patients with PAOD. In a prospective subgroup analysis of patients randomized between MRA and DSA (n = 79) for preoperative imaging, QoL questionnaires (SF-36) were obtained at randomization and at 4-month follow-up. Cost-effectiveness from hospital perspective was subsequently compared between groups and the difference in gained or lost QoL per € spent assessed using bootstrap analysis. No difference in quality of life was found. A treatment trajectory employing MRA as the principal imaging modality was almost 20% cheaper, leading to a better cost-utility ratio in favor of MRA. A treatment plan for peripheral arterial occlusive disease employing MRA versus DSA as the principal imaging modality yields a better cost/QoL ratio for MRA.

  10. Obliterative portal venopathy: A histopathologic finding associated with chronic antibody-mediated rejection in pediatric liver allografts.

    PubMed

    Guerra, Marjorie-Anne R; Naini, Bita V; Scapa, Jason V; Reed, Elaine F; Busuttil, Ronald W; Cheng, Elaine Y; Farmer, Douglas G; Vargas, Jorge H; Venick, Robert S; McDiarmid, Sue V; Wozniak, Laura J

    2018-03-01

    The significance of post-transplant HLA DSA and chronic AMR in LT is an emerging field of study. Although OPV has previously been described as a histopathologic finding in DSA-positive adult LT recipients, it was not included in the recent Banff criteria for chronic AMR. Our aim was to describe the association between OPV and chronic AMR in pediatric LT recipients. A retrospective review of 67 liver biopsies performed between November 2014 and April 2016 in 45 pediatric LT recipients identified four patients with OPV. Clinical status, liver biochemistry, the presence of DSA, and available non-HLA antibody testing, as well as histopathologic features of chronic AMR, were assessed. All four patients with OPV had class II DSA and histopathologic features of chronic AMR based on the Banff criteria. Two patients were noted to have non-HLA antibodies. Three patients are undergoing treatment with IVIG but have persistent DSA. Two patients have graft failure and are awaiting retransplantation. In conclusion, OPV is a histopathologic finding associated with chronic AMR in pediatric LT recipients. Further studies are needed to elucidate whether OPV is reversible and/or amenable to medical therapy. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Arterial imaging in patients with lower extremity ischemia and diabetes mellitus.

    PubMed

    Pomposelli, Frank

    2010-09-01

    Precise, comprehensive imaging of the arterial circulation is the cornerstone of successful revascularization of the ischemic extremity in patients with diabetes mellitus. Arterial imaging is challenging in these patients because the disease is often multisegmental with a predilection for the distal tibial and peroneal arteries. Occlusive lesions and the arterial wall itself are often calcified and patients presenting with ischemic complications frequently have underlying renal insufficiency. Intra-arterial digital subtraction angiography (DSA), contrast enhanced magnetic resonance angiography (MRA), and more recently, computerized tomographic angiography (CTA) have been used as imaging modalities in lower extremity ischemia. Each has specific advantages and shortcomings in this patient population, which will be summarized and contrasted in this review. DSA is an invasive technique most often performed from a femoral arterial puncture and requires the injection of arterial contrast, which can occasionally cause allergic reactions. In patients with pre-existing renal insufficiency, contrast infusion can result in worsening renal failure; although usually self-limited, it may occasionally require hemodialysis, especially in patients with diabetes. However, DSA provides the highest degree of spatial resolution and image quality. It is also the only modality in which the diagnosis and treatment of arterial disease can be performed simultaneously. MRA is noninvasive, and when enhanced with gadolinium contrast injection provides arterial images of comparable quality to DSA and in some circumstances may uncover distal arterial targets not visualized on DSA. However, spatial resolution is inferior to DSA and erroneous interpretations due to acquisition artifacts are common. Specialized equipment and imaging techniques are necessary to minimize their occurrence in the distal lower extremity. In addition, due to the risk of inducing nephrogenic systemic fibrosis, gadolinium-enhanced MRA cannot be used in patients with renal insufficiency. CTA is noninvasive and rapidly performed, with better spatial resolution than MRA, but requires the largest volume of contrast infusion, exposes patients to high-doses of radiation, and is subject to interpretive error due to reconstruction artifacts especially in heavily calcified arteries, limiting its usefulness in many patients with diabetes. For patients in whom the planned intervention is a surgical bypass, DSA and MRA will provide high quality images of the lower extremity arterial anatomy. For patients in whom a catheter-based intervention is the likely treatment, a diagnostic DSA immediately followed by a catheter-based treatment in the same procedure is the preferred approach. In patients with pre-existing renal dysfunction, in which gadolinium-enhanced MRA is contraindicated, DSA or CTA can be performed. However, patients should have an infusion of intravenous normal saline solution or sodium bicarbonate before the procedure to reduce the incidence of contrast-induced nephropathy. Copyright © 2010. Published by Mosby, Inc.

  12. A covert authentication and security solution for GMOs.

    PubMed

    Mueller, Siguna; Jafari, Farhad; Roth, Don

    2016-09-21

    Proliferation and expansion of security risks necessitates new measures to ensure authenticity and validation of GMOs. Watermarking and other cryptographic methods are available which conceal and recover the original signature, but in the process reveal the authentication information. In many scenarios watermarking and standard cryptographic methods are necessary but not sufficient and new, more advanced, cryptographic protocols are necessary. Herein, we present a new crypto protocol, that is applicable in broader settings, and embeds the authentication string indistinguishably from a random element in the signature space and the string is verified or denied without disclosing the actual signature. Results show that in a nucleotide string of 1000, the algorithm gives a correlation of 0.98 or higher between the distribution of the codon and that of E. coli, making the signature virtually invisible. This algorithm may be used to securely authenticate and validate GMOs without disclosing the actual signature. While this protocol uses watermarking, its novelty is in use of more complex cryptographic techniques based on zero knowledge proofs to encode information.

  13. Radar Detection of Marine Mammals

    DTIC Science & Technology

    2011-09-30

    BFT-BPT algorithm for use with our radar data. This track - before - detect algorithm had been effective in enhancing small but persistent signatures in...will be possible with the detect before track algorithm. 4 We next evaluated the track before detect algorithm, the BFT-BPT, on the CEDAR data

  14. Comparison of remnant size in embolized intracranial aneurysms measured at follow-up with DSA and MRA.

    PubMed

    Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2012-12-01

    The possibility of recanalization and the need for retreatment are the most important limitations of intracranial aneurysm embolization. The purpose of the study was to compare the size of aneurysm remnants measured at follow-up with three-dimensional digital subtracted angiography (3D-DSA) and magnetic resonance angiography (MRA). Twenty-six aneurysms were found incompletely occluded in 72 consecutively examined patients at a follow-up after 3 months. The diameters and volume of aneurysm remnants were compared between 3D-DSA, time-of-flight MRA (TOF-MRA), contrast-enhanced TOF-MRA (CE-TOF-MRA), and contrast-enhanced MRA (CE-MRA) at 1.5 T. There was a significant correlation between remnant volumes calculated based on 3D-DSA and all MRA modalities. The intraobserver variability of the measurements ranged from 3.4 to 4.1 % and the interobserver variability from 5.8 to 7.3 %. There were no significant differences in the variability between the techniques. The mean residual filling volume ranged from 16.3 ± 19.0 mm(3) in TOF-MRA to 30.5 ± 44.6 mm(3) in 3D-DSA (P < 0.04). Significant differences were found in the volumes measured with 3D-DSA and CE-MRA as compared to TOF-MRA and CE-TOF-MRA (P < 0.01). There was a moderate significant correlation between the residual filling and the relative error of measurement in the case of TOF-MRA and CE-TOF-MRA. TOF-MRA seems to underestimate the size of aneurysm remnants detected at follow-up and should not be used as a sole imaging method to decide on re-embolization.

  15. Optimal MRI sequence for identifying occlusion location in acute stroke: which value of time-resolved contrast-enhanced MRA?

    PubMed

    Le Bras, A; Raoult, H; Ferré, J-C; Ronzière, T; Gauvrit, J-Y

    2015-06-01

    Identifying occlusion location is crucial for determining the optimal therapeutic strategy during the acute phase of ischemic stroke. The purpose of this study was to assess the diagnostic efficacy of MR imaging, including conventional sequences plus time-resolved contrast-enhanced MRA in comparison with DSA for identifying arterial occlusion location. Thirty-two patients with 34 occlusion levels referred for thrombectomy during acute cerebral stroke events were consecutively included from August 2010 to December 2012. Before thrombectomy, we performed 3T MR imaging, including conventional 3D-TOF and gradient-echo T2 sequences, along with time-resolved contrast-enhanced MRA of the extra- and intracranial arteries. The 3D-TOF, gradient-echo T2, and time-resolved contrast-enhanced MRA results were consensually assessed by 2 neuroradiologists and compared with prethrombectomy DSA results in terms of occlusion location. The Wilcoxon test was used for statistical analysis to compare MR imaging sequences with DSA, and the κ coefficient was used to determine intermodality agreement. The occlusion level on the 3D-TOF and gradient-echo T2 images differed significantly from that of DSA (P < .001 and P = .002, respectively), while no significant difference was observed between DSA and time-resolved contrast-enhanced MRA (P = .125). κ coefficients for intermodality agreement with DSA (95% CI, percentage agreement) were 0.43 (0.3%-0.6; 62%), 0.32 (0.2%-0.5; 56%), and 0.81 (0.6%-1.0; 88%) for 3D-TOF, gradient-echo T2, and time-resolved contrast-enhanced MRA, respectively. The time-resolved contrast-enhanced MRA sequence proved reliable for identifying occlusion location in acute stroke with performance superior to that of 3D-TOF and gradient-echo T2 sequences. © 2015 by American Journal of Neuroradiology.

  16. Interest of HYPR flow dynamic MRA for characterization of cerebral arteriovenous malformations: comparison with TRICKS MRA and catheter DSA.

    PubMed

    Dautry, Raphaël; Edjlali, Myriam; Roca, Pauline; Rabrait, Cécile; Wu, Yijing; Johnson, Kevin; Wieben, Olivier; Trystram, Denis; Rodriguez-Régent, Christine; Alshareef, Fawaz; Turski, Patrick; Meder, Jean-François; Naggara, Olivier; Oppenheim, Catherine

    2015-11-01

    HYPR flow is a 3D dynamic contrast-enhanced MRA technique providing isotropic sub-millimetre resolution with half-second temporal resolution. We compared HYPR flow and time-resolved imaging of contrast kinetics (TRICKS) MRA for the characterization of cerebral arteriovenous malformations (cAVMs), using catheter DSA as reference. Twenty-two patients underwent HYPR flow and TRICKS MRA within 15 days of DSA. HYPR flow and TRICKS datasets were reviewed separately by two readers for image quality, Spetzler-Martin grade, venous ectasia, and deep venous drainage. Image quality was better for HYPR flow than for TRICKS (narrower full width at half maximum; larger arterial diagnostic window; greater number of arterial frames, P ≤ 0.05). Using HYPR flow, inter-reader agreement was excellent for all cAVM characteristics. The agreement with DSA for the overall Spetzler-Martin grade was excellent for HYPR flow (ICC = 0.96 and 0.98, depending on the reader) and TRICKS (ICC = 0.82 and 0.95). In comparison to TRICKS, HYPR flow showed higher concordance with DSA for the identification of venous ectasia and deep venous drainage. Owing to an excellent agreement with DSA with respect to depiction of the vascular architecture of cAVMs, HYPR flow could be useful for the non-invasive characterization of cAVMs. • Dynamic MRA is used for cerebral AVM depiction and follow-up • HYPR flow is a new, highly-resolved dynamic MRA sequence • HYPR flow provides whole brain coverage • HYPR flow provides excellent agreement with the Spetzler-Martin grade • Compared to TRICKS MRA, HYPR flow improves cerebral AVM characterization.

  17. Non-contrast-enhanced MRA of renal artery stenosis: validation against DSA in a porcine model.

    PubMed

    Bley, T A; François, C J; Schiebler, M L; Wieben, O; Takei, N; Brittain, J H; Del Rio, A Munoz; Grist, T M; Reeder, S B

    2016-02-01

    To compare 3D-inversion-recovery balanced steady-state free precession (IR-bSSFP) non-contrast-enhanced magnetic resonance angiography (MRA) with 3D-contrast-enhanced MRA (CE-MRA) for assessment of renal artery stenosis (RAS) using digital subtraction angiography (DSA) as the reference standard. Bilateral RAS were surgically created in 12 swine. IR-bSSFP and CE-MRA were acquired at 1.5 T and compared to rotational DSA. Three experienced cardiovascular radiologists evaluated the IR-bSSFP and CE-MRA studies independently. Linear regression models were used to calibrate and assess the accuracy of IR-bSSFP and CE-MRA, separately, against DSA. The coefficient of determination and Cohen's kappa coefficient were also generated. Calibration of the three readers' RAS grading revealed R(2) values of 0.52, 0.37 and 0.59 for NCE-MRA and 0.48, 0.53 and 0.71 for CE-MRA. Inter-rater agreement demonstrated Cohen's kappa values ranging from 0.25 to 0.65. Distal renal artery branch vessels were visible to a significantly higher degree with NCE-MRA compared to CE-MRA (p < 0.001). Image quality was rated excellent for both sequences, although image noise was higher with CE-MRA (p < 0.05). In no cases did noise interfere with image interpretation. In a well-controlled animal model of surgically induced RAS, IR-bSSFP based NCE-MRA and CE-MRA accurately graded RAS with a tendency for stenosis overestimation, compared to DSA. • IR-bSSFP and CE-MRA are accurate methods for diagnosis of renal artery stenosis • IR-bSSFP and CE-MRA demonstrate excellent agreement with DSA • Both IR-bSSFP and CE-MRA have a tendency to overestimate renal artery stenosis.

  18. Comparison of ferumoxytol-enhanced MRA with conventional angiography for assessment of severity of transplant renal artery stenosis.

    PubMed

    Fananapazir, Ghaneh; Bashir, Mustafa R; Corwin, Michael T; Lamba, Ramit; Vu, Catherine T; Troppmann, Christoph

    2017-03-01

    To determine the accuracy of ferumoxytol-enhanced magnetic resonance angiography (MRA) in assessing the severity of transplant renal artery stenosis (TRAS), using digital subtraction angiography (DSA) as the reference standard. Our Institutional Review Board approved this retrospective, Health Insurance Portability and Accountability Act-compliant study. Thirty-three patients with documented clinical suspicion for TRAS (elevated serum creatinine, refractory hypertension, edema, and/or audible bruit) and/or concerning sonographic findings (elevated renal artery velocity and/or intraparenchymal parvus tardus waveforms) underwent a 1.5T MRA with ferumoxytol prior to DSA. All DSAs were independently reviewed by an interventional radiologist and served as the reference standard. The MRAs were reviewed by three readers who were blinded to the ultrasound and DSA findings for the presence and severity of TRAS. Sensitivity, specificity, and accuracy for identifying substantial stenoses (>50%) were determined. Intraclass correlation coefficients (ICCs) were calculated among readers. Mean differences between the percent stenosis from each MRA reader and DSA were calculated. On DSA, a total of 42 stenoses were identified in the 33 patients. The sensitivity, specificity, and accuracy of MRA in detecting substantial stenoses were 100%, 75-87.5%, and 95.2-97.6%, respectively, among the readers. There was excellent agreement among readers as to the percent stenosis (ICC = 0.82). MRA overestimated the degree of stenosis by 3.9-9.6% compared to DSA. Ferumoxytol-enhanced MRA provides high sensitivity, specificity, and accuracy for determining the severity of TRAS. Our results suggest that it can potentially be used as a noninvasive examination following ultrasound to reduce the number of unnecessary conventional angiograms. 3 J. Magn. Reson. Imaging 2017;45:779-785. © 2016 International Society for Magnetic Resonance in Medicine.

  19. CE-MRA for follow-up of aneurysms post stent-assisted coiling.

    PubMed

    Agid, R; Schaaf, M; Farb, Ri

    2012-09-01

    This study compared the accuracy of contrast-enhanced MR angiography (CE-MRA) to intra-arterial cerebral angiography (IA-DSA) for assessment of intracranial aneurysms after stent-assisted coiling and to check if the presence of a stent in the parent artery diminishes the accuracy of CE-MRA. Consecutive patients with cerebral aneurysms treated by stent-assisted coiling were evaluated retrospectively. Matching follow-up CE-MRA and IA-DSA were evaluated separately. Evaluation included the presence of aneurysmal remnant, patency and stenosis of parent artery. Twenty-seven patients with 28 aneurysms and 33 matched CE-MRA and IA-DSA studies were evaluated. Nineteen aneurysmal remnants were seen on CE-MRA and 16 on IA-DSA. CE-MRA diagnosed three aneurysmal remnants not appreciated on IA-DSA. Five other remnants were larger on CE-MRA than IA-DSA. None of the remnants were missed on CE-MRA. Parent arteries were patent on both modalities. CE-MRA showed false stenosis of the stented artery in six cases and exaggerated stenosis in two. In 18 cases, CE-MRA showed a short focal "pseudo-stenosis" where the stent's marker bands were located. This was noted whenever the stent's marker bands were located in an artery with luminal diameter ≤2 mm and was called "marker band effect". CE-MRA is an accurate technique for follow-up of aneurysms post stent-assisted coiling with excellent depiction of remnants in spite of the presence of a stent. Apparent stenosis of the stented parent artery on CE-MRA is often false or exaggerated. "Marker band effect" should be recognized as an artifact that appears when stent's marker bands are in a small artery.

  20. CE-MRA for Follow-up of Aneurysms Post Stent-Assisted Coiling

    PubMed Central

    Agid, R.; Schaaf, M.; Farb, RI.

    2012-01-01

    Summary This study compared the accuracy of contrast-enhanced MR angiography (CE-MRA) to intra-arterial cerebral angiography (IA-DSA) for assessment of intracranial aneurysms after stent-assisted coiling and to check if the presence of a stent in the parent artery diminishes the accuracy of CE-MRA. Consecutive patients with cerebral aneurysms treated by stent-assisted coiling were evaluated retrospectively. Matching follow-up CE-MRA and IA-DSA were evaluated separately. Evaluation included the presence of aneurysmal remnant, patency and stenosis of parent artery. Twenty-seven patients with 28 aneurysms and 33 matched CE-MRA and IA-DSA studies were evaluated. Nineteen aneurysmal remnants were seen on CE-MRA and 16 on IA-DSA. CE-MRA diagnosed three aneurysmal remnants not appreciated on IA-DSA. Five other remnants were larger on CE-MRA than IA-DSA. None of the remnants were missed on CE-MRA. Parent arteries were patent on both modalities. CE-MRA showed false stenosis of the stented artery in six cases and exaggerated stenosis in two. In 18 cases, CE-MRA showed a short focal “pseudo-stenosis” where the stent’s marker bands were located. This was noted whenever the stent’s marker bands were located in an artery with luminal diameter ≤2 mm and was called “marker band effect”. CE-MRA is an accurate technique for follow-up of aneurysms post stent-assisted coiling with excellent depiction of remnants in spite of the presence of a stent. Apparent stenosis of the stented parent artery on CE-MRA is often false or exaggerated. “Marker band effect” should be recognized as an artifact that appears when stent’s marker bands are in a small artery. PMID:22958765

  1. Use of the Dye Stain Assay and Ultraviolet Light Test for Assessing Vaginal Insertion of Placebo-filled Applicators Before and After Sex

    PubMed Central

    Keller, Marla J.; Buckley, Niall; Katzen, Lauren L.; Walsh, Jennifer; Friedland, Barbara; Littlefield, Sarah; Lin, Juan; Xue, Xiaonan; Cornelison, Terri; Herold, Betsy C.; Einstein, Mark H.

    2014-01-01

    Background Applicator dye staining and ultraviolet (UV) light have been used in trials to measure adherence, but not in the setting of before and after sex gel dosing (BAT-24). This study was designed to determine if semen or pre-sex gel dosing impacts the sensitivity and specificity of a dye stain assay (DSA) for measuring vaginal insertion of placebo-filled applicators with BAT-24 dosing. Methods Healthy monogamous couples received Microlax®-type applicators filled with hydroxyethylcelluose placebo gel. Women were instructed to vaginally insert one dose of gel before and a second dose after sex and to return applicators within 48 hours after sex. Applicators were stained to detect semen followed by UV then DSA and scored by two readers. Positive and negative controls were randomly included in applicator batches. Results Fifteen couples completed the study. Each female returned at least six applicators over a 30-day period. The sensitivity for insertion of post-sex applicators was higher for UV (97%) compared to DSA (90%) and the specificity was similar (≥96%). For pre-sex applicators, the sensitivity and specificity were higher for DSA (100%) compared to UV testing (87% sensitivity, 96% specificity). Among returned post-sex applicators, 95% tested positive by UV compared to 87% by DSA. Agreement between readers was significantly better on the pre-sex applicators for DSA than for UV and for post-sex readings agreement was less than half that for UV, although the results were not statistically significant. Conclusions Applicator tests are feasible for measuring adherence in trials with gel dosing before and after sex. PMID:24220355

  2. Evaluation of Three Approaches for Assessing Adherence to Vaginal Gel Application in Clinical Trials

    PubMed Central

    van der Straten, Ariane; Cheng, Helen; Mensch, Barbara; Friedland, Barbara; Katzen, Lauren; Littlefield, Sarah; Buckley, Niall; Espinoza, Lilia; Keller, Marla J.; Herold, Betsy C.; Einstein, Mark H.

    2014-01-01

    Background: Accurate measurement of adherence to product use is an ongoing challenge in microbicide trials. Methods: We compared adherence estimates using two applicator tests (a dye stain assay [DSA] and an ultraviolet light assay [UVA]), the Wisebag (an applicator container that electronically tracks container openings), and self-reported adherence (ability, frequency, and percent missed doses). Healthy, HIV-negative, non-pregnant US women aged 23 to 45 received a Wisebag and 32 applicators filled with placebo gel, were instructed to insert one applicator daily for 30 days, returned the Wisebag and all applicators, and completed an exit interview. Emptied applicators were tested by UVA and then DSA, and scored by two blinded readers. Positive and negative controls were randomly included in applicator batches. Results: Among 42 women enrolled, 39 completed the study. DSA and UVA yielded similar sensitivity (97% and 95%) and specificity (79% and 79%). Two participants had fully inoperable Wisebags and nine had partially inoperable Wisebags. The proportion of participants considered to have high adherence (≥80%) varied: 43% (Wisebag), 46% (UVA), 49% (DSA), and 62% to 82% (self-reports). For estimating high adherence, Wisebag had a sensitivity of 76% (95% CI, 50% to 93%) and a specificity of 85% (95% CI, 62% to 97%) compared with DSA. Although 28% of participants reported forgetting to open the Wisebag daily, 59% said it helped them remember gel use. Conclusions: DSA and UVA performed similarly. Compared with these tests, self-reports overestimated and Wisebag underestimated adherence. Although Wisebag may encourage gel use, the applicator tests currently appear more useful for measuring use in clinical trials. PMID:24220357

  3. Acceleration of low-energy ions at parallel shocks with a focused transport model

    DOE PAGES

    Zuo, Pingbing; Zhang, Ming; Rassoul, Hamid K.

    2013-04-10

    Here, we present a test particle simulation on the injection and acceleration of low-energy suprathermal particles by parallel shocks with a focused transport model. The focused transport equation contains all necessary physics of shock acceleration, but avoids the limitation of diffusive shock acceleration (DSA) that requires a small pitch angle anisotropy. This simulation verifies that the particles with speeds of a fraction of to a few times the shock speed can indeed be directly injected and accelerated into the DSA regime by parallel shocks. At higher energies starting from a few times the shock speed, the energy spectrum of acceleratedmore » particles is a power law with the same spectral index as the solution of standard DSA theory, although the particles are highly anisotropic in the upstream region. The intensity, however, is different from that predicted by DSA theory, indicating a different level of injection efficiency. It is found that the shock strength, the injection speed, and the intensity of an electric cross-shock potential (CSP) jump can affect the injection efficiency of the low-energy particles. A stronger shock has a higher injection efficiency. In addition, if the speed of injected particles is above a few times the shock speed, the produced power-law spectrum is consistent with the prediction of standard DSA theory in both its intensity and spectrum index with an injection efficiency of 1. CSP can increase the injection efficiency through direct particle reflection back upstream, but it has little effect on the energetic particle acceleration once the speed of injected particles is beyond a few times the shock speed. This test particle simulation proves that the focused transport theory is an extension of DSA theory with the capability of predicting the efficiency of particle injection.« less

  4. Electrochemical oxidation of bio-refractory dye in a simulated textile industry effluent using DSA electrodes in a filter-press type FM01-LC reactor.

    PubMed

    Rodríguez, Francisca A; Mateo, María N; Aceves, Juan M; Rivero, Eligio P; González, Ignacio

    2013-01-01

    This work presents a study on degradation of indigo carmine dye in a filter-press type FM01-LC reactor using Sb2O5-doped Ti/IrO2-SnO2 dimensionally stable anode (DSA) electrodes. Micro- and macroelectrolysis studies were carried out using solutions of 0.8 mM indigo carmine in 0.05 M NaCl, which resemble blue denim laundry industrial wastewater. Microelectrolysis results show the behaviour of DSA electrodes in comparison with the behaviour of boron-doped diamond (BDD) electrodes. In general, dye degradation reactions are carried out indirectly through active chlorine generated on DSA, whereas in the case of BDD electrodes more oxidizing species are formed, mainly OH radicals, on the electrode surface. The well-characterized geometry, flow pattern and mass transport of the FM01-LC reactor used in macroelectrolysis experiments allowed the evaluation of the effect of hydrodynamic conditions on the chlorine-mediated degradation rate. Four values of Reynolds number (Re) (93, 371, 464 and 557) at four current densities (50, 100, 150 and 200 A/m2) were tested. The results show that the degradation rate is independent of Re at low current density (50 A/m2) but becomes dependent on the Re at high current density (200 A/m2). This behaviour shows the central role of mass transport and the reactor parameters and design. The low energy consumption (2.02 and 9.04 kWh/m3 for complete discolouration and chemical oxygen demand elimination at 50 A/m2, respectively) and the low cost of DSA electrodes compared to BDD make DSA electrodes promising for practical application in treating industrial textile effluents. In the present study, chlorinated organic compounds were not detected.

  5. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin Mingde; Marshall, Craig T.; Qi, Yi

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, aremore » invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 {mu}m{sup 2}). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0{+-}5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO{sub DSA}=CO{sub Fick}. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.« less

  6. 3D digital subtraction angiography of intracranial aneurysms: comparison of flat panel detector with conventional image intensifier TV system using a vascular phantom.

    PubMed

    Kakeda, S; Korogi, Y; Ohnari, N; Hatakeyama, Y; Moriya, J; Oda, N; Nishino, K; Miyamoto, W

    2007-05-01

    Compared with the image intensifier (I.I.)-TV system, the flat panel detector (FPD) system of direct conversion type has several theoretic advantages, such as higher spatial resolution, wide dynamic range, and no image distortion. The purpose of this study was to compare the image quality of 3D digital subtraction angiography (DSA) in the FPD and conventional I.I.-TV systems using a vascular phantom. An anthropomorphic vascular phantom was designed to simulate the various intracranial aneurysms with aneurysmal bleb. The tubes of this vascular phantom were filled with 2 concentrations of contrast material (300 and 150 mg I/mL), and we obtained 3D DSA using the FPD and I.I.-TV systems. First, 2 blinded radiologists compared the volume-rendering images for 3D DSA on the FPD and I.I.-TV systems, looking for pseudostenosis artifacts. Then, 2 other radiologists independently evaluated both systems for the depiction of the simulated aneurysm and aneurysmal bleb using a 5-point scale. For the degree of the pseudostenosis artifacts at the M1 segment of the middle cerebral artery at 300 mg I/mL, 3D DSA with FPD system showed mild stenoses, whereas severe stenoses were observed at 3D DSA with I.I.-TV system. At both concentrations, the FPD system was significantly superior to I.I.-TV system regarding the depiction of aneurysm and aneurysmal bleb. Compared with the I.I.-TV system, the FPD system could create high-resolution 3D DSA combined with a reduction of the pseudostenosis artifacts.

  7. Effective doses in children: association with common complex imaging techniques used during interventional radiology procedures.

    PubMed

    Lai, Priscilla; McNeil, Sarah M; Gordon, Christopher L; Connolly, Bairbre L

    2014-12-01

    The purpose of this study was to determine the range of effective doses associated with imaging techniques used during interventional radiology procedures on children. A pediatric phantom set (1, 5, and 10 years) coupled with high-sensitivity metal oxide semiconductor field effect transistor (MOSFET) dosimeters was used to calculate effective doses. Twenty MOSFETs were inserted into each phantom at radiosensitive organ locations. The phantoms were exposed to mock head, chest, and abdominal interventional radiology procedures performed with different geometries and magnifications. Fluoroscopy, digital subtraction angiography (DSA), and spin angiography were simulated on each phantom. Road mapping was conducted only on the 5-year-old phantom. International Commission on Radiological Protection publication 103 tissue weights were applied to the organ doses recorded with the MOSFETs to determine effective dose. For easy application to clinical cases, doses were normalized per minute of fluoroscopy and per 10 frames of DSA or spin angiography. Effective doses from DSA, angiography, and fluoroscopy were higher for younger ages because of magnification use and were largest for abdominal procedures. DSA of the head, chest, and abdomen (normalized per 10 frames) imparted doses 2-3 times as high as corresponding doses per minute of fluoroscopy while all other factors remained unchanged (age, projection, collimation, magnification). Three to five frames of DSA imparted an effective dose equal to doses from 1 minute of fluoroscopy. Doses from spin angiography were almost one-half the doses received from an equivalent number of frames of DSA. Patient effective doses during interventional procedures vary substantially depending on procedure type but tend to be higher because of magnification use in younger children and higher in the abdomen.

  8. Many de novo donor‐specific antibodies recognize β2‐microglobulin‐free, but not intact HLA heterodimers

    PubMed Central

    Michel, K.; Santella, R.; Steers, J.; Sahajpal, A.; Downey, F. X.; Thohan, V.

    2016-01-01

    Abstract Solid‐phase single antigen bead (SAB) assays are standard of care for detection and identification of donor‐specific antibody (DSA) in patients who receive solid organ transplantation (SOT). While several studies have documented the reproducibility and sensitivity of SAB testing for DSA, there are little data available concerning its specificity. This study describes the identification of antibodies to β2‐microglobulin‐free human leukocyte antigen (β2‐m‐fHLA) heavy chains on SAB arrays and provides a reassessment of the clinical relevance of DSA testing by this platform. Post‐transplant sera from 55 patients who were positive for de novo donor‐specific antibodies on a SAB solid‐phase immunoassay were tested under denaturing conditions in order to identify antibodies reactive with β2‐m‐fHLA or native HLA (nHLA). Antibodies to β2‐m‐fHLA were present in nearly half of patients being monitored in the post‐transplant period. The frequency of antibodies to β2‐m‐fHLA was similar among DSA and HLA antigens that were irrelevant to the transplant (non‐DSA). Among the seven patients with clinical or pathologic antibody‐mediated rejection (AMR), none had antibodies to β2‐m‐fHLA exclusively; thus, the clinical relevance of β2‐m‐fHLA is unclear. Our data suggests that SAB testing produces false positive reactions due to the presence of β2‐m‐fHLA and these can lead to inappropriate assignment of unacceptable antigens during transplant listing and possibly inaccurate identification of DSA in the post‐transplant period. PMID:27060279

  9. Laser vibrometry exploitation for vehicle identification

    NASA Astrophysics Data System (ADS)

    Nolan, Adam; Lingg, Andrew; Goley, Steve; Sigmund, Kevin; Kangas, Scott

    2014-06-01

    Vibration signatures sensed from distant vehicles using laser vibrometry systems provide valuable information that may be used to help identify key vehicle features such as engine type, engine speed, and number of cylinders. Through the use of physics models of the vibration phenomenology, features are chosen to support classification algorithms. Various individual exploitation algorithms were developed using these models to classify vibration signatures into engine type (piston vs. turbine), engine configuration (Inline 4 vs. Inline 6 vs. V6 vs. V8 vs. V12) and vehicle type. The results of these algorithms will be presented for an 8 class problem. Finally, the benefits of using a factor graph representation to link these independent algorithms together will be presented which constructs a classification hierarchy for the vibration exploitation problem.

  10. Absence of dynamic strain aging in an additively manufactured nickel-base superalloy.

    PubMed

    Beese, Allison M; Wang, Zhuqing; Stoica, Alexandru D; Ma, Dong

    2018-05-25

    Dynamic strain aging (DSA), observed macroscopically as serrated plastic flow, has long been seen in nickel-base superalloys when plastically deformed at elevated temperatures. Here we report the absence of DSA in Inconel 625 made by additive manufacturing (AM) at temperatures and strain rates where DSA is present in its conventionally processed counterpart. This absence is attributed to the unique AM microstructure of finely dispersed secondary phases (carbides, N-rich phases, and Laves phase) and textured grains. Based on experimental observations, we propose a dislocation-arrest model to elucidate the criterion for DSA to occur or to be absent as a competition between dislocation pipe diffusion and carbide-carbon reactions. With in situ neutron diffraction studies of lattice strain evolution, our findings provide a new perspective for mesoscale understanding of dislocation-solute interactions and their impact on work-hardening behaviors in high-temperature alloys, and have important implications for tailoring thermomechanical properties by microstructure control via AM.

  11. TU-H-CAMPUS-IeP1-04: Combined Organ Dose for Digital Subtraction Angiography and Computed Tomography Using Monte Carlo Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakabe, D; Ohno, T; Araki, F

    Purpose: The purpose of this study was to evaluate the combined organ dose of digital subtraction angiography (DSA) and computed tomography (CT) using a Monte Carlo (MC) simulation on the abdominal intervention. Methods: The organ doses for DSA and CT were obtained with MC simulation and actual measurements using fluorescent-glass dosimeters at 7 abdominal portions in an Alderson-Rando phantom. DSA was performed from three directions: posterior anterior (PA), right anterior oblique (RAO), and left anterior oblique (LAO). The organ dose with MC simulation was compared with actual radiation dose measurements. Calculations for the MC simulation were carried out with themore » GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. Finally, the combined organ dose for DSA and CT was calculated from the MC simulation using the X-ray conditions of a patient with a diagnosis of hepatocellular carcinoma. Results: For DSA from the PA direction, the organ doses for the actual measurements and MC simulation were 2.2 and 2.4 mGy/100 mAs at the liver, respectively, and 3.0 and 3.1 mGy/100 mAs at the spinal cord, while for CT, the organ doses were 15.2 and 15.1 mGy/100 mAs at the liver, and 14.6 and 13.5 mGy/100 mAs at the spinal cord. The maximum difference in organ dose between the actual measurements and the MC simulation was 11.0% of the spleen at PA, 8.2% of the spinal cord at RAO, and 6.1% of left kidney at LAO with DSA and 9.3% of the stomach with CT. The combined organ dose (4 DSAs and 6 CT scans) with the use of actual patient conditions was found to be 197.4 mGy for the liver and 205.1 mGy for the spinal cord. Conclusion: Our method makes it possible to accurately assess the organ dose to patients for abdominal intervention with combined DSA and CT.« less

  12. Quantitative flow and velocity measurements of pulsatile blood flow with 4D-DSA

    NASA Astrophysics Data System (ADS)

    Shaughnessy, Gabe; Hoffman, Carson; Schafer, Sebastian; Mistretta, Charles A.; Strother, Charles M.

    2017-03-01

    Time resolved 3D angiographic data from 4D DSA provides a unique environment to explore physical properties of blood flow. Utilizing the pulsatility of the contrast waveform, the Fourier components can be used to track the waveform motion through vessels. Areas of strong pulsatility are determined through the FFT power spectrum. Using this method, we find an accuracy from 4D-DSA flow measurements within 7.6% and 6.8% RMSE of ICA PCVIPR and phantom flow probe validation measurements, respectively. The availability of velocity and flow information with fast acquisition could provide a more quantitative approach to treatment planning and evaluation in interventional radiology.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    AISL-CRYPTO is a library of cryptography functions supporting other AISL software. It provides various crypto functions for Common Lisp, including Digital Signature Algorithm, Data Encryption Standard, Secure Hash Algorithm, and public-key cryptography.

  14. Priority and Negotiation Based Dynamic Spectrum Allocation Scheme for Multiple Radio Access Network Operators

    NASA Astrophysics Data System (ADS)

    Kim, Hoon; Hyon, Taein; Lee, Yeonwoo

    Most of previous works have presented the dynamic spectrum allocation (DSA) gain achieved by utilizing the time or regional variations in traffic demand between multi-network operators (NOs). In this paper, we introduce the functionalities required for the entities related with the spectrum sharing and allocation and propose a spectrum allocation algorithm while considering the long-term priority between NOs, the priority between multiple class services, and the urgent bandwidth request. To take into account the priorities among the NOs and the priorities of multiple class services, a spectrum sharing metric (SSM) is proposed, while a negotiation procedure is proposed to treat the urgent bandwidth request.

  15. Combining a Disturbance Observer with Triple-Loop Control Based on MEMS Accelerometers for Line-of-Sight Stabilization

    PubMed Central

    Huang, Yongmei; Deng, Chao; Ren, Wei; Wu, Qiongyan

    2017-01-01

    In the CCD-based fine tracking optical system (FTOS), the whole disturbance suppression ability (DSA) is the product of the inner loop and outer position loop. Traditionally, high sampling fiber-optic gyroscopes (FOGs) are added to the platform to stabilize the line-of-sight (LOS). However, because of the FOGs’ high cost and relatively big volume relative to the back narrow space of small rotating mirrors, we attempt in this work to utilize a cheaper and smaller micro-electro-mechanical system (MEMS) accelerometer to build the inner loop, replacing the FOG. Unfortunately, since accelerometers are susceptible to the low-frequency noise, according to the classical way of using accelerometers, the crucial low-frequency DSA of the system is insufficient. To solve this problem, in this paper, we propose an approach based on MEMS accelerometers combining disturbance observer (DOB) with triple-loop control (TLC) in which the composite velocity loop is built by acceleration integration and corrected by CCD. The DOB is firstly used to reform the platform, greatly improving the medium-frequency DSA. Then the composite velocity loop exchanges a part of medium-frequency performance for the low-frequency DSA. A detailed analysis and experiments verify the proposed method has a better DSA than the traditional way and could totally substitute FOG in the LOS stabilization. PMID:29149050

  16. Quadriplegia caused by an epidural abscess occurring at the same level of cervical destructive spondyloarthropathy: a case report.

    PubMed

    Lee, Jun-Seok; Ryu, Ji-Hyun; Park, Jong-Tae; Kim, Ki-Won

    2017-01-10

    Destructive spondyloarthropathy (DSA) is one of the major complications in patients undergoing long-term hemodialysis. To the best of our knowledge, an epidural abscess occurring at the level of preexisting cervical DSA has not been well described in the literature. We report a unique case of quadriplegia caused by an epidural abscess occurring at the same level of preexisting cervical DSA. A 49-year-old woman was transferred to our emergency department with 5 days of sepsis, drowsy mental status, and quadriplegia below the C5 level. The patient had a medical history of hemodialysis for 10 years. Magnetic resonance imaging showed spinal cord compression by an epidural abscess at the level of preexisting cervical DSA. Blood culture revealed methicillin-sensitive Staphylococcus aureus. Infection of the arteriovenous (AV) shunt was considered as the primary focus of sepsis and pyogenic spondylitis. We performed an emergent open door laminoplasty and the vascular team debrided the infected AV shunt site. Approximately 8 months after surgery, the patient was able to perform activities of daily living somewhat independently. Emergent surgical decompression and intensive medical care led to successful recovery from a septic and quadriplegic state in this patient. When diagnosing a patient who has undergone long-term hemodialysis presenting with neurologic deficits, the possibility of infectious spondylitis at the same level as DSA should be considered.

  17. Outcome after Desensitization in HLA or ABO-Incompatible Kidney Transplant Recipients: A Single Center Experience.

    PubMed

    Kauke, Teresa; Klimaschewski, Sandra; Schoenermarck, Ulf; Fischereder, Michael; Dick, Andrea; Guba, Markus; Stangl, Manfred; Werner, Jens; Meiser, Bruno; Habicht, Antje

    2016-01-01

    The shortage of deceased donors led to an increase of living donor kidney (LDK) transplantations performed in the presence of donor-specific antibodies (DSA) or ABO incompatibility (ABOi) using various desensitization protocols. We herein analyzed 26 ABOi and 8 Luminex positive DSA patients who were successfully desensitized by anti-CD20, antigen-specific immunoadsorption and/or plasmapheresis to receive an LDK transplant. Twenty LDK recipients with non-donor-specific HLA-antibodies (low risk) and 32 without anti-HLA antibodies (no risk) served as control groups. 1-year graft survival rate and renal function was similar in all 4 groups (creatinine: 1.63 ± 0.5 vs 1.78 ± 0.6 vs 1.64 ± 0.5 vs 1.6 ± 0.3 mg/dl in ABOi, DSA, low risk and no risk group). The incidence of acute T-cell mediated rejections did not differ between the 4 groups (15% vs 12, 5% vs 15% vs 22% in ABOi, DSA, low risk and no risk), while antibody-mediated rejections were only found in the DSA (25%) and ABOi (7.5%) groups. Incidence of BK nephropathy (BKVN) was significantly more frequent after desensitization as compared to controls (5/34 vs 0/52, p = 0.03). We demonstrate favorable short-term allograft outcome in LDK transplant recipients after desensitization. However, the desensitization was associated with an increased risk of BKVN.

  18. Cost identification of abdominal aortic aneurysm imaging by using time and motion analyses.

    PubMed

    Rubin, G D; Armerding, M D; Dake, M D; Napel, S

    2000-04-01

    To compare the costs of performing helical computed tomographic (CT) angiography with three-dimensional rendering versus intraarterial digital subtraction angiography (DSA) for preoperative imaging of abdominal aortic aneurysms (AAAs). A single observer determined the variable direct costs of performing nine intraarterial DSA and 10 CT angiographic examinations in age- and general health-matched patients with AAA by using time and motion analyses. All personnel directly involved in the cases were tracked, and the involvement times were recorded to the nearest minute. All material items used during the procedures were recorded. The cost of labor was determined from personnel reimbursement data, and the cost of materials, from vendor pricing. The variable direct costs of laboratory tests and using the ambulatory treatment unit for postprocedural monitoring, as well as all fixed direct costs, were assessed from hospital accounting records. The total costs were determined for each procedure and compared by using the Student t test and calculating the CIs. The mean total direct cost of intraarterial DSA (+/- SD) was $1,052 +/- 71, and that of CT angiography was $300 +/- 30, which are significantly different (P < 4.1 x 10(-11)). With 95% confidence, intraarterial DSA cost 3.2-3.7 times more than CT angiography for the assessment of AAA. Assuming equal diagnostic utility and procedure-related morbidity, institutions may have substantial cost savings whenever CT angiography can replace intraarterial DSA for imaging AAAs.

  19. Follow-up of intracranial aneurysms treated by a WEB flow disrupter: a comparative study of DSA and contrast-enhanced MR angiography.

    PubMed

    Mine, Benjamin; Tancredi, Illario; Aljishi, Ali; Alghamdi, Faisal; Beltran, Margarita; Herchuelz, Maxime; Lubicz, Boris

    2016-06-01

    To compare contrast-enhanced MR angiography (CE-MRA) and DSA for the follow-up of intracranial aneurysms (IAs) treated with the Woven EndoBridge embolization system DL (WEB DL; Sequent Medical, Aliso Viejo, California, USA). We retrospectively identified all patients treated with a WEB DL between November 2010 and February 2013 in 2 hospitals. The IA occlusion was graded on follow-up CE-MRA and DSA by 4 independent readers and by 2 readers reaching a consensus, respectively. Interobserver agreement for MRA and intertechnique agreement was evaluated by calculating linear weighted κ. Fifteen patients with 16 IAs were included. Mean delay between MRA and DSA was 2 months (range 0-16 months). Interobserver agreement for MRA was substantial to almost perfect (κ=0.686-0.921; mean κ=0.809). Intertechnique agreement was moderate to substantial (κ=0.579-0.724; mean κ=0.669). Only three out of five inadequately occluded IAs were detected by MRA. CE-MRA is a useful tool for the follow-up of IAs treated with a WEB DL. However, early follow-up with DSA remains mandatory to detect inadequately occluded IAs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. A Weak Quantum Blind Signature with Entanglement Permutation

    NASA Astrophysics Data System (ADS)

    Lou, Xiaoping; Chen, Zhigang; Guo, Ying

    2015-09-01

    Motivated by the permutation encryption algorithm, a weak quantum blind signature (QBS) scheme is proposed. It involves three participants, including the sender Alice, the signatory Bob and the trusted entity Charlie, in four phases, i.e., initializing phase, blinding phase, signing phase and verifying phase. In a small-scale quantum computation network, Alice blinds the message based on a quantum entanglement permutation encryption algorithm that embraces the chaotic position string. Bob signs the blinded message with private parameters shared beforehand while Charlie verifies the signature's validity and recovers the original message. Analysis shows that the proposed scheme achieves the secure blindness for the signer and traceability for the message owner with the aid of the authentic arbitrator who plays a crucial role when a dispute arises. In addition, the signature can neither be forged nor disavowed by the malicious attackers. It has a wide application to E-voting and E-payment system, etc.

  1. Classification of a large microarray data set: Algorithm comparison and analysis of drug signatures

    PubMed Central

    Natsoulis, Georges; El Ghaoui, Laurent; Lanckriet, Gert R.G.; Tolley, Alexander M.; Leroy, Fabrice; Dunlea, Shane; Eynon, Barrett P.; Pearson, Cecelia I.; Tugendreich, Stuart; Jarnagin, Kurt

    2005-01-01

    A large gene expression database has been produced that characterizes the gene expression and physiological effects of hundreds of approved and withdrawn drugs, toxicants, and biochemical standards in various organs of live rats. In order to derive useful biological knowledge from this large database, a variety of supervised classification algorithms were compared using a 597-microarray subset of the data. Our studies show that several types of linear classifiers based on Support Vector Machines (SVMs) and Logistic Regression can be used to derive readily interpretable drug signatures with high classification performance. Both methods can be tuned to produce classifiers of drug treatments in the form of short, weighted gene lists which upon analysis reveal that some of the signature genes have a positive contribution (act as “rewards” for the class-of-interest) while others have a negative contribution (act as “penalties”) to the classification decision. The combination of reward and penalty genes enhances performance by keeping the number of false positive treatments low. The results of these algorithms are combined with feature selection techniques that further reduce the length of the drug signatures, an important step towards the development of useful diagnostic biomarkers and low-cost assays. Multiple signatures with no genes in common can be generated for the same classification end-point. Comparison of these gene lists identifies biological processes characteristic of a given class. PMID:15867433

  2. Tomographic digital subtraction angiography for lung perfusion estimation in rodents.

    PubMed

    Badea, Cristian T; Hedlund, Laurence W; De Lin, Ming; Mackel, Julie S Boslego; Samei, Ehsan; Johnson, G Allan

    2007-05-01

    In vivo measurements of perfusion present a challenge to existing small animal imaging techniques such as magnetic resonance microscopy, micro computed tomography, micro positron emission tomography, and microSPECT, due to combined requirements for high spatial and temporal resolution. We demonstrate the use of tomographic digital subtraction angiography (TDSA) for estimation of perfusion in small animals. TDSA augments conventional digital subtraction angiography (DSA) by providing three-dimensional spatial information using tomosynthesis algorithms. TDSA is based on the novel paradigm that the same time density curves can be reproduced in a number of consecutive injections of microL volumes of contrast at a series of different angles of rotation. The capabilities of TDSA are established in studies on lung perfusion in rats. Using an imaging system developed in-house, we acquired data for four-dimensional (4D) imaging with temporal resolution of 140 ms, in-plane spatial resolution of 100 microm, and slice thickness on the order of millimeters. Based on a structured experimental approach, we optimized TDSA imaging providing a good trade-off between slice thickness, the number of injections, contrast to noise, and immunity to artifacts. Both DSA and TDSA images were used to create parametric maps of perfusion. TDSA imaging has potential application in a number of areas where functional perfusion measurements in 4D can provide valuable insight into animal models of disease and response to therapeutics.

  3. Beyond the scope of Free-Wilson analysis: building interpretable QSAR models with machine learning algorithms.

    PubMed

    Chen, Hongming; Carlsson, Lars; Eriksson, Mats; Varkonyi, Peter; Norinder, Ulf; Nilsson, Ingemar

    2013-06-24

    A novel methodology was developed to build Free-Wilson like local QSAR models by combining R-group signatures and the SVM algorithm. Unlike Free-Wilson analysis this method is able to make predictions for compounds with R-groups not present in a training set. Eleven public data sets were chosen as test cases for comparing the performance of our new method with several other traditional modeling strategies, including Free-Wilson analysis. Our results show that the R-group signature SVM models achieve better prediction accuracy compared with Free-Wilson analysis in general. Moreover, the predictions of R-group signature models are also comparable to the models using ECFP6 fingerprints and signatures for the whole compound. Most importantly, R-group contributions to the SVM model can be obtained by calculating the gradient for R-group signatures. For most of the studied data sets, a significant correlation with that of a corresponding Free-Wilson analysis is shown. These results suggest that the R-group contribution can be used to interpret bioactivity data and highlight that the R-group signature based SVM modeling method is as interpretable as Free-Wilson analysis. Hence the signature SVM model can be a useful modeling tool for any drug discovery project.

  4. A Quantum Proxy Blind Signature Scheme Based on Genuine Five-Qubit Entangled State

    NASA Astrophysics Data System (ADS)

    Zeng, Chuan; Zhang, Jian-Zhong; Xie, Shu-Cui

    2017-06-01

    In this paper, a quantum proxy blind signature scheme based on controlled quantum teleportation is proposed. This scheme uses a genuine five-qubit entangled state as quantum channel and adopts the classical Vernam algorithm to blind message. We use the physical characteristics of quantum mechanics to implement delegation, signature and verification. Security analysis shows that our scheme is valid and satisfy the properties of a proxy blind signature, such as blindness, verifiability, unforgeability, undeniability.

  5. Exploring the Use of Radar for a Physically Based Lightning Cessation Nowcasting Tool

    NASA Technical Reports Server (NTRS)

    Schultz, Elise V.; Petersen, Walter A.; Carey, Lawrence D.

    2011-01-01

    NASA s Marshall Space Flight Center (MSFC) and the University of Alabama in Huntsville (UAHuntsville) are collaborating with the 45th Weather Squadron (45WS) at Cape Canaveral Air Force Station (CCAFS) to enable improved nowcasting of lightning cessation. This project centers on use of dual-polarimetric radar capabilities, and in particular, the new C-band dual-polarimetric weather radar acquired by the 45WS. Special emphasis is placed on the development of a physically based operational algorithm to predict lightning cessation. While previous studies have developed statistically based lightning cessation algorithms, we believe that dual-polarimetric radar variables offer the possibility to improve existing algorithms through the inclusion of physically meaningful trends reflecting interactions between in-cloud electric fields and hydrometeors. Specifically, decades of polarimetric radar research using propagation differential phase has demonstrated the presence of distinct phase and ice crystal alignment signatures in the presence of strong electric fields associated with lightning. One question yet to be addressed is: To what extent can these ice-crystal alignment signatures be used to nowcast the cessation of lightning activity in a given storm? Accordingly, data from the UAHuntsville Advanced Radar for Meteorological and Operational Research (ARMOR) along with the NASA-MSFC North Alabama Lightning Mapping Array are used in this study to investigate the radar signatures present before and after lightning cessation. Thus far, our case study results suggest that the negative differential phase shift signature weakens and disappears after the analyzed storms ceased lightning production (i.e., after the last lightning flash occurred). This is a key observation because it suggests that while strong electric fields may still have been present, the lightning cessation signature encompassed the period of the polarimetric negative phase shift signature. To the extent this behavior is repeatable in other cases, even if only in a substantial fraction of those cases, the case analyses suggests that differential propagation phase may prove to be a useful parameter for future lightning cessation algorithms. Indeed, analysis of 15+ cases has shown additional indications of the weakening and disappearance of this ice alignment signature with lightning cessation. A summary of results will be presented.

  6. CoGAPS matrix factorization algorithm identifies transcriptional changes in AP-2alpha target genes in feedback from therapeutic inhibition of the EGFR network

    PubMed Central

    Thakar, Manjusha; Howard, Jason D.; Kagohara, Luciane T.; Krigsfeld, Gabriel; Ranaweera, Ruchira S.; Hughes, Robert M.; Perez, Jimena; Jones, Siân; Favorov, Alexander V.; Carey, Jacob; Stein-O'Brien, Genevieve; Gaykalova, Daria A.; Ochs, Michael F.; Chung, Christine H.

    2016-01-01

    Patients with oncogene driven tumors are treated with targeted therapeutics including EGFR inhibitors. Genomic data from The Cancer Genome Atlas (TCGA) demonstrates molecular alterations to EGFR, MAPK, and PI3K pathways in previously untreated tumors. Therefore, this study uses bioinformatics algorithms to delineate interactions resulting from EGFR inhibitor use in cancer cells with these genetic alterations. We modify the HaCaT keratinocyte cell line model to simulate cancer cells with constitutive activation of EGFR, HRAS, and PI3K in a controlled genetic background. We then measure gene expression after treating modified HaCaT cells with gefitinib, afatinib, and cetuximab. The CoGAPS algorithm distinguishes a gene expression signature associated with the anticipated silencing of the EGFR network. It also infers a feedback signature with EGFR gene expression itself increasing in cells that are responsive to EGFR inhibitors. This feedback signature has increased expression of several growth factor receptors regulated by the AP-2 family of transcription factors. The gene expression signatures for AP-2alpha are further correlated with sensitivity to cetuximab treatment in HNSCC cell lines and changes in EGFR expression in HNSCC tumors with low CDKN2A gene expression. In addition, the AP-2alpha gene expression signatures are also associated with inhibition of MEK, PI3K, and mTOR pathways in the Library of Integrated Network-Based Cellular Signatures (LINCS) data. These results suggest that AP-2 transcription factors are activated as feedback from EGFR network inhibition and may mediate EGFR inhibitor resistance. PMID:27650546

  7. Internet Protocol Security (IPSEC): Testing and Implications on IPv4 and IPv6 Networks

    DTIC Science & Technology

    2008-08-27

    Message Authentication Code-Message Digest 5-96). Due to the processing power consumption and slowness of public key authentication methods, RSA ...MODP) group with a 768 -bit modulus 2. a MODP group with a 1024-bit modulus 3. an Elliptic Curve Group over GF[ 2n ] (EC2N) group with a 155-bit...nonces, digital signatures using the Digital Signature Algorithm, and the Rivest-Shamir- Adelman ( RSA ) algorithm. For more information about the

  8. Photonic quantum digital signatures operating over kilometer ranges in installed optical fiber

    NASA Astrophysics Data System (ADS)

    Collins, Robert J.; Fujiwara, Mikio; Amiri, Ryan; Honjo, Toshimori; Shimizu, Kaoru; Tamaki, Kiyoshi; Takeoka, Masahiro; Andersson, Erika; Buller, Gerald S.; Sasaki, Masahide

    2016-10-01

    The security of electronic communications is a topic that has gained noteworthy public interest in recent years. As a result, there is an increasing public recognition of the existence and importance of mathematically based approaches to digital security. Many of these implement digital signatures to ensure that a malicious party has not tampered with the message in transit, that a legitimate receiver can validate the identity of the signer and that messages are transferable. The security of most digital signature schemes relies on the assumed computational difficulty of solving certain mathematical problems. However, reports in the media have shown that certain implementations of such signature schemes are vulnerable to algorithmic breakthroughs and emerging quantum processing technologies. Indeed, even without quantum processors, the possibility remains that classical algorithmic breakthroughs will render these schemes insecure. There is ongoing research into information-theoretically secure signature schemes, where the security is guaranteed against an attacker with arbitrary computational resources. One such approach is quantum digital signatures. Quantum signature schemes can be made information-theoretically secure based on the laws of quantum mechanics while comparable classical protocols require additional resources such as anonymous broadcast and/or a trusted authority. Previously, most early demonstrations of quantum digital signatures required dedicated single-purpose hardware and operated over restricted ranges in a laboratory environment. Here, for the first time, we present a demonstration of quantum digital signatures conducted over several kilometers of installed optical fiber. The system reported here operates at a higher signature generation rate than previous fiber systems.

  9. 34 CFR 367.11 - What assurances must a DSA include in its application?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 2 2014-07-01 2013-07-01 true What assurances must a DSA include in its application? 367.11 Section 367.11 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION AND REHABILITATIVE SERVICES, DEPARTMENT OF EDUCATION INDEPENDENT LIVING...

  10. 34 CFR 367.11 - What assurances must a DSA include in its application?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 34 Education 2 2012-07-01 2012-07-01 false What assurances must a DSA include in its application? 367.11 Section 367.11 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION AND REHABILITATIVE SERVICES, DEPARTMENT OF EDUCATION INDEPENDENT LIVING...

  11. 34 CFR 367.11 - What assurances must a DSA include in its application?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 34 Education 2 2013-07-01 2013-07-01 false What assurances must a DSA include in its application? 367.11 Section 367.11 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION AND REHABILITATIVE SERVICES, DEPARTMENT OF EDUCATION INDEPENDENT LIVING...

  12. 34 CFR 367.41 - When may a DSA award grants or contracts?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 2 2010-07-01 2010-07-01 false When may a DSA award grants or contracts? 367.41 Section 367.41 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION AND REHABILITATIVE SERVICES, DEPARTMENT OF EDUCATION INDEPENDENT LIVING SERVICES FOR...

  13. 34 CFR 367.41 - When may a DSA award grants or contracts?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 2 2011-07-01 2010-07-01 true When may a DSA award grants or contracts? 367.41 Section 367.41 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION AND REHABILITATIVE SERVICES, DEPARTMENT OF EDUCATION INDEPENDENT LIVING SERVICES FOR...

  14. 34 CFR 367.10 - How does a designated State agency (DSA) apply for an award?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 2 2010-07-01 2010-07-01 false How does a designated State agency (DSA) apply for an award? 367.10 Section 367.10 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION AND REHABILITATIVE SERVICES, DEPARTMENT OF EDUCATION INDEPENDENT...

  15. 34 CFR 367.10 - How does a designated State agency (DSA) apply for an award?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 34 Education 2 2011-07-01 2010-07-01 true How does a designated State agency (DSA) apply for an award? 367.10 Section 367.10 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL EDUCATION AND REHABILITATIVE SERVICES, DEPARTMENT OF EDUCATION INDEPENDENT...

  16. The role of time-resolved imaging of contrast kinetics (TRICKS) magnetic resonance angiography (MRA) in the evaluation of head-neck vascular anomalies: a preliminary experience.

    PubMed

    Romano, A; Tavanti, F; Rossi Espagnet, M C; Terenzi, V; Cassoni, A; Suma, G; Boellis, A; Pierallini, A; Valentini, V; Bozzao, A

    2015-01-01

    In this preliminary report, we describe our experience with time-resolved imaging of contrast kinetics-MR angiography (TRICKS-MRA) in the assessment of head-neck vascular anomalies (HNVAs). We prospectively studied six consecutive patients with clinically suspected or diagnosed HNVAs. All of them underwent TRICKS-MRA of the head and neck as part of the routine for treatment planning. A digital subtraction angiography (DSA) was also performed. TRICKS-MRA could be achieved in all cases. Three subjects were treated based on TRICKS-MRA imaging findings and subsequent DSA examination. In all of them, DSA confirmed the vascular architecture of HNVAs shown by TRICKS-MRA. In the other three patients, a close follow up to assess the evolution of the suspected haemangioma was preferred. TRICKS sequences add important diagnostic information in cases of HNVAs, helpful for therapeutic decisions and post-treatment follow up. We recommend TRICKS-MRA use (if technically possible) as part of routine MRI protocol for HNVAs, representing a possible alternative imaging tool to conventional DSA.

  17. Using process monitor wafers to understand directed self-assembly defects

    NASA Astrophysics Data System (ADS)

    Cao, Yi; Her, YoungJun; Delgadillo, Paulina R.; Vandenbroeck, Nadia; Gronheid, Roel; Chan, Boon Teik; Hashimoto, Yukio; Romo, Ainhoa; Somervell, Mark; Nafus, Kathleen; Nealey, Paul F.

    2013-03-01

    As directed self-assembly (DSA) has gained momentum over the past few years, questions about its application to high volume manufacturing have arisen. One of the major concerns is about the fundamental limits of defectivity that can be attained with the technology. If DSA applications demonstrate defectivity that rivals of traditional lithographic technologies, the pathway to the cost benefits of the technology creates a very compelling case for its large scale implementation. To address this critical question, our team at IMEC has established a process monitor flow to track the defectivity behaviors of an exemplary chemo-epitaxy application for printing line/space patterns. Through establishing this baseline, we have been able to understand both traditional lithographic defect sources in new materials as well as new classes of assembly defects associated with DSA technology. Moreover, we have explored new materials and processing to lower the level of the defectivity baseline. The robustness of the material sets and process is investigated as well. In this paper, we will report the understandings learned from the IMEC DSA process monitor flow.

  18. Supporting Dynamic Spectrum Access in Heterogeneous LTE+ Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luiz A. DaSilva; Ryan E. Irwin; Mike Benonis

    As early as 2014, mobile network operators’ spectral capac- ity is expected to be overwhelmed by the demand brought on by new devices and applications. With Long Term Evo- lution Advanced (LTE+) networks likely as the future one world 4G standard, network operators may need to deploy a Dynamic Spectrum Access (DSA) overlay in Heterogeneous Networks (HetNets) to extend coverage, increase spectrum efficiency, and increase the capacity of these networks. In this paper, we propose three new management frameworks for DSA in an LTE+ HetNet: Spectrum Accountability Client, Cell Spectrum Management, and Domain Spectrum Man- agement. For these spectrum managementmore » frameworks, we define protocol interfaces and operational signaling scenar- ios to support cooperative sensing, spectrum lease manage- ment, and alarm scenarios for rule adjustment. We also quan- tify, through integer programs, the benefits of using DSA in an LTE+ HetNet, that can opportunistically reuse vacant TV and GSM spectrum. Using integer programs, we consider a topology using Geographic Information System data from the Blacksburg, VA metro area to assess the realistic benefits of DSA in an LTE+ HetNet.« less

  19. Effect of nitrogen on high temperature low cycle fatigue behaviors in type 316L stainless steel

    NASA Astrophysics Data System (ADS)

    Kim, Dae Whan; Ryu, Woo-Seog; Hong, Jun Hwa; Choi, Si-Kyung

    1998-04-01

    Strain-controlled low cycle fatigue (LCF) tests were conducted in the temperature range of RT-600°C and air atmosphere to investigate the nitrogen effect on LCF behavior of type 316L stainless steels with different nitrogen contents (0.04-0.15%). The waveform of LCF was a symmetrical triangle with a strain amplitude of ±0.5% and a constant strain rate of 2×10 -3/s was employed for most tests. Cyclic stress response of the alloys exhibited a gradual cyclic softening at RT, but a cyclic hardening at an early stage of fatigue life at 300-600°C. The hardening at high temperature was attributed to dynamic strain aging (DSA). Nitrogen addition decreased hardening magnitude (maximum cyclic stress — first cyclic stress) because nitrogen retarded DSA for these conditions. The dislocation structures were changed from cell to planar structure with increasing temperature and nitrogen addition by DSA and short range order (SRO). Fatigue life was a maximum at 0.1% nitrogen content, which was attributed to the balance between DSA and SRO.

  20. Visualization and Classification of Deeply Seated Collateral Networks in Moyamoya Angiopathy with 7T MRI.

    PubMed

    Matsushige, T; Kraemer, M; Sato, T; Berlit, P; Forsting, M; Ladd, M E; Jabbarli, R; Sure, U; Khan, N; Schlamann, M; Wrede, K H

    2018-06-07

    Collateral networks in Moyamoya angiopathy have a complex angioarchitecture difficult to comprehend on conventional examinations. This study aimed to evaluate morphologic patterns and the delineation of deeply seated collateral networks using ultra-high-field MRA in comparison with conventional DSA. Fifteen white patients with Moyamoya angiopathy were investigated in this prospective trial. Sequences acquired at 7T were TOF-MRA with 0.22 × 0.22 × 0.41 mm 3 resolution and MPRAGE with 0.7 × 0.7 × 0.7 mm 3 resolution. Four raters evaluated the presence of deeply seated collateral networks and image quality in a consensus reading of DSA, TOF-MRA, and MPRAGE using a 5-point scale in axial source images and maximum intensity projections. Delineation of deeply seated collateral networks by different imaging modalities was compared by means of the McNemar test, whereas image quality was compared using the Wilcoxon signed-rank test. The relevant deeply seated collateral networks were classified into 2 categories and 6 pathways. A total of 100 collateral networks were detected on DSA; 106, on TOF-MRA; and 73, on MPRAGE. Delineation of deeply seated collateral networks was comparable between TOF-MRA and DSA ( P = .25); however, both were better than MPRAGE ( P < .001). This study demonstrates excellent delineation of 6 distinct deeply seated collateral network pathways in Moyamoya angiopathy in white adults using 7T TOF-MRA, comparable to DSA. © 2018 by American Journal of Neuroradiology.

  1. Outcome after Desensitization in HLA or ABO-Incompatible Kidney Transplant Recipients: A Single Center Experience

    PubMed Central

    Kauke, Teresa; Klimaschewski, Sandra; Schoenermarck, Ulf; Fischereder, Michael; Dick, Andrea; Guba, Markus; Stangl, Manfred; Werner, Jens; Meiser, Bruno; Habicht, Antje

    2016-01-01

    Background The shortage of deceased donors led to an increase of living donor kidney (LDK) transplantations performed in the presence of donor-specific antibodies (DSA) or ABO incompatibility (ABOi) using various desensitization protocols. Methods We herein analyzed 26 ABOi and 8 Luminex positive DSA patients who were successfully desensitized by anti-CD20, antigen-specific immunoadsorption and/or plasmapheresis to receive an LDK transplant. Twenty LDK recipients with non-donor-specific HLA-antibodies (low risk) and 32 without anti-HLA antibodies (no risk) served as control groups. Results 1-year graft survival rate and renal function was similar in all 4 groups (creatinine: 1.63 ± 0.5 vs 1.78 ± 0.6 vs 1.64 ± 0.5 vs 1.6 ± 0.3 mg/dl in ABOi, DSA, low risk and no risk group). The incidence of acute T-cell mediated rejections did not differ between the 4 groups (15% vs 12, 5% vs 15% vs 22% in ABOi, DSA, low risk and no risk), while antibody-mediated rejections were only found in the DSA (25%) and ABOi (7.5%) groups. Incidence of BK nephropathy (BKVN) was significantly more frequent after desensitization as compared to controls (5/34 vs 0/52, p = 0.03). Conclusion We demonstrate favorable short-term allograft outcome in LDK transplant recipients after desensitization. However, the desensitization was associated with an increased risk of BKVN. PMID:26730981

  2. Efficacy of induction therapy with ATG and intravenous immunoglobulins in patients with low-level donor-specific HLA-antibodies.

    PubMed

    Bächler, K; Amico, P; Hönger, G; Bielmann, D; Hopfer, H; Mihatsch, M J; Steiger, J; Schaub, S

    2010-05-01

    Low-level donor-specific HLA-antibodies (HLA-DSA) (i.e. detectable by single-antigen flow beads, but negative by complement-dependent cytotoxicity crossmatch) represent a risk factor for early allograft rejection. The short-term efficacy of an induction regimen consisting of polyclonal anti-T-lymphocyte globulin (ATG) and intravenous immunoglobulins (IvIg) in patients with low-level HLA-DSA is unknown. In this study, we compared 67 patients with low-level HLA-DSA not having received ATG/IvIg induction (historic control) with 37 patients, who received ATG/IvIg induction. The two groups were equal regarding retransplants, HLA-matches, number and class of HLA-DSA. The overall incidence of clinical/subclinical antibody-mediated rejection (AMR) was lower in the ATG/IvIg than in the historic control group (38% vs. 55%; p = 0.03). This was driven by a significantly lower rate of clinical AMR (11% vs. 46%; p = 0.0002). Clinical T-cell-mediated rejection (TCR) was significantly lower in the ATG/IvIg than in the historic control group (0% vs. 50%; p < 0.0001). Within the first year, allograft loss due to AMR occurred in 7.5% in the historic control and in 0% in the ATG/IvIg group. We conclude that in patients with low-level HLA-DSA, ATG/IvIg induction significantly reduces TCR and the severity of AMR, but the high rate of subclinical AMR suggests an insufficient control of the humoral immune response.

  3. Combining Diffusive Shock Acceleration with Acceleration by Contracting and Reconnecting Small-scale Flux Ropes at Heliospheric Shocks

    NASA Astrophysics Data System (ADS)

    le Roux, J. A.; Zank, G. P.; Webb, G. M.; Khabarova, O. V.

    2016-08-01

    Computational and observational evidence is accruing that heliospheric shocks, as emitters of vorticity, can produce downstream magnetic flux ropes and filaments. This led Zank et al. to investigate a new paradigm whereby energetic particle acceleration near shocks is a combination of diffusive shock acceleration (DSA) with downstream acceleration by many small-scale contracting and reconnecting (merging) flux ropes. Using a model where flux-rope acceleration involves a first-order Fermi mechanism due to the mean compression of numerous contracting flux ropes, Zank et al. provide theoretical support for observations that power-law spectra of energetic particles downstream of heliospheric shocks can be harder than predicted by DSA theory and that energetic particle intensities should peak behind shocks instead of at shocks as predicted by DSA theory. In this paper, a more extended formalism of kinetic transport theory developed by le Roux et al. is used to further explore this paradigm. We describe how second-order Fermi acceleration, related to the variance in the electromagnetic fields produced by downstream small-scale flux-rope dynamics, modifies the standard DSA model. The results show that (I) this approach can qualitatively reproduce observations of particle intensities peaking behind the shock, thus providing further support for the new paradigm, and (II) stochastic acceleration by compressible flux ropes tends to be more efficient than incompressible flux ropes behind shocks in modifying the DSA spectrum of energetic particles.

  4. COMBINING DIFFUSIVE SHOCK ACCELERATION WITH ACCELERATION BY CONTRACTING AND RECONNECTING SMALL-SCALE FLUX ROPES AT HELIOSPHERIC SHOCKS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le Roux, J. A.; Zank, G. P.; Webb, G. M.

    2016-08-10

    Computational and observational evidence is accruing that heliospheric shocks, as emitters of vorticity, can produce downstream magnetic flux ropes and filaments. This led Zank et al. to investigate a new paradigm whereby energetic particle acceleration near shocks is a combination of diffusive shock acceleration (DSA) with downstream acceleration by many small-scale contracting and reconnecting (merging) flux ropes. Using a model where flux-rope acceleration involves a first-order Fermi mechanism due to the mean compression of numerous contracting flux ropes, Zank et al. provide theoretical support for observations that power-law spectra of energetic particles downstream of heliospheric shocks can be harder thanmore » predicted by DSA theory and that energetic particle intensities should peak behind shocks instead of at shocks as predicted by DSA theory. In this paper, a more extended formalism of kinetic transport theory developed by le Roux et al. is used to further explore this paradigm. We describe how second-order Fermi acceleration, related to the variance in the electromagnetic fields produced by downstream small-scale flux-rope dynamics, modifies the standard DSA model. The results show that (i) this approach can qualitatively reproduce observations of particle intensities peaking behind the shock, thus providing further support for the new paradigm, and (ii) stochastic acceleration by compressible flux ropes tends to be more efficient than incompressible flux ropes behind shocks in modifying the DSA spectrum of energetic particles.« less

  5. Follow-up of intracranial aneurysms treated with stent-assisted coiling: Comparison of contrast-enhanced MRA, time-of-flight MRA, and digital subtraction angiography.

    PubMed

    Marciano, David; Soize, Sébastien; Metaxas, Georgios; Portefaix, Christophe; Pierot, Laurent

    2017-02-01

    Data about non-invasive follow-up of aneurysm after stent-assisted coiling is scarce. We aimed to compare time-of-flight (TOF) magnetic resonance angiography (MRA) (3D-TOF-MRA) and contrast-enhanced MRA (CE-MRA) at 3-Tesla, with digital subtraction angiography (DSA) for evaluating aneurysm occlusion and parent artery patency after stent-assisted coiling. In this retrospective single-center study, patients were included if they had an intracranial aneurysm treated by stent-assisted coiling between March 2008 and June 2015, followed with both MRA sequences (3D-TOF-MRA and CE-MRA) at 3-Tesla and DSA, performed in an interval<48hours. Thirty-five aneurysms were included. Regarding aneurysm occlusion evaluation, agreement with DSA was better for CE-MRA (K=0.53) than 3D-TOF-MRA (K=0.28). Diagnostic accuracies for aneurysm remnant depiction were similar for 3D-TOF-MRA and CE-MRA (P=1). Both 3D-TOF-MRA (K=0.05) and CE-MRA (K=-0.04) were unable to detect pathological vessel compared to DSA, without difference in accuracy (P=0.68). For parent artery occlusion detection, agreement with DSA was substantial for 3D-TOF-MRA (K=0.64) and moderate for CE-MRA (K=0.45), with similar good diagnostic accuracies (P=1). After stent-assisted coiling treatment, 3D-TOF-MRA and CE-MRA demonstrated good accuracy to detect aneurysm remnant (but tended to overestimation). Although CE-MRA agreement with DSA was better, there was no statistical difference between 3D-TOF-MRA and CE-MRA accuracies. Both MRAs were unable to provide a precise evaluation of in-stent status but could detect parent vessel occlusion. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Dynamic Strain Aging Phenomena and Tensile Response of Medium-Mn TRIP Steel

    NASA Astrophysics Data System (ADS)

    Field, Daniel M.; Van Aken, David C.

    2018-04-01

    Dynamic strain aging (DSA) and rapid work hardening are typical behaviors observed in medium-Mn transformation-induced plasticity (TRIP) steel. Three alloys with manganese ranging from 10.2 to 13.8 wt pct with calculated room temperature stacking fault energies varying from - 2.1 to 0.7 mJ/m2 were investigated. Significant serrations were observed in the stress-strain behavior for two of the steels and the addition of 4.6 wt pct chromium was effective in significantly reducing the occurrence of DSA. Addition of chromium to the alloy reduced DSA by precipitation of M23(C,N)6 during batch annealing at 873 K (600 °C) for 20 hours. Three distinct DSA mechanisms were identified: one related to manganese ordering in stacking faults associated with ɛ-martensite and austenite interface, with activation energies for the onset and termination of DSA being 145 and 277 kJ/mol. A second mechanism was associated with carbon diffusion in γ-austenite where Mn-C bonding added to the total binding energy, and activation energies of 88 and 155 kJ/mol were measured for the onset and termination of DSA. A third mechanism was attributed to dislocation pinning and unpinning by nitrogen in α-ferrite with activation energies of 64 and 123 kJ/mol being identified. Tensile behaviors of the three medium manganese steels were studied in both the hot band and batch annealed after cold working conditions. Ultimate tensile strengths ranged from 1310 to 1404 MPa with total elongation of 24.1 to 34.1 pct. X-ray diffraction (XRD) was used to determine the transformation response of the steels using interrupted tensile tests at room temperature. All three of the processed steels showed evidence of two-stage TRIP where γ-austenite first transformed to ɛ-martensite, and subsequently transformed to α-martensite.

  7. Transarterial onyx embolization of cranial dural arteriovenous fistulas: long-term follow-up.

    PubMed

    Chandra, R V; Leslie-Mazwi, T M; Mehta, B P; Yoo, A J; Rabinov, J D; Pryor, J C; Hirsch, J A; Nogueira, R G

    2014-09-01

    Endovascular therapy with liquid embolic agents is a common treatment strategy for cranial dural arteriovenous fistulas. This study evaluated the long-term effectiveness of transarterial Onyx as the single embolic agent for curative embolization of noncavernous cranial dural arteriovenous fistulas. We performed a retrospective review of 40 consecutive patients with 41 cranial dural arteriovenous fistulas treated between March 2006 and June 2012 by using transarterial Onyx embolization with intent to cure. The mean age was 57 years; one-third presented with intracranial hemorrhage. Most (85%) had cortical venous drainage. Once angiographic cure was achieved, long-term treatment effectiveness was assessed with DSA and clinical follow-up. Forty-nine embolization sessions were performed; 85% of cranial dural arteriovenous fistulas were treated in a single session. The immediate angiographic cure rate was 95%. The permanent neurologic complication rate was 2% (mild facial palsy). Thirty-five of the 38 patients with initial cure underwent short-term follow-up DSA (median, 4 months). The short-term recurrence rate was only 6% (2/35). All patients with occlusion at short-term DSA undergoing long-term DSA (median, 28 months) had durable occlusion. No patient with long-term clinical follow-up (total, 117 patient-years; median, 45 months) experienced hemorrhage. Transarterial embolization with Onyx as the single embolic agent results in durable long-term cure of noncavernous cranial dural arteriovenous fistulas. Recurrence rates are low on short-term follow-up, and all patients with angiographic occlusion on short-term DSA follow-up have experienced a durable long-term cure. Thus, angiographic cure should be defined at short-term follow-up angiography instead of at the end of the final embolization session. Finally, long-term DSA follow-up may not be necessary if occlusion is demonstrated on short-term angiographic follow-up. © 2014 by American Journal of Neuroradiology.

  8. [Digital angiography and lipiodol computerized tomography in the anatomopathological framework of hepatocarcinoma].

    PubMed

    Pozzi-Mucelli, R; Pozzi-Mucelli, R; Pagnan, L; Dalla Palma, L

    1994-12-01

    The introduction of therapies other than conventional surgery of hepatocellular carcinoma (HCC) requires an accurate pathologic classification, which is important because it is well known that HCC may have multicentric growth. The Liver Cancer Study Group of Japan has proposed a classification dividing HCCs into three macroscopic forms from the pathologic point of view: nodular, massive and infiltrating HCCs. The nodular type is subdivided into four types: single nodular type, single nodular type with surrounding proliferation, multinodular fused type and multinodular type. Forty-six HCC patients were examined with Lipiodol Computed Tomography (LCT) to investigate the agreement between pathologic and imaging findings. LCT proved to be in close agreement with pathologic findings. Sixteen cases were classified as type I (single nodular type), 8 as type II (single nodular type with limited foci), 1 as type III (multinodular fused type), 18 as type IV (multiple nodular type with diffuse foci) and 3 cases as type V (massive form). No cases of infiltrative forms were observed in our series. Based on LCT findings, the capabilities of digital subtraction angiography (DSA) were studied in the pathologic classification of HCCs. DSA exhibited some limitations in the pathologic classification of HCCs in 5 of 16 patients with type I lesions. In these cases DSA suggested false-positive diagnoses because of regenerative nodules in cirrhotic liver in 3 cases and of daughter nodules (not confirmed at LCT) in 2 cases. In 7 of 8 patients with type II HCCs, DSA failed to show the daughter nodules surrounding the main nodule. In the 18 patients with multiple distant nodules (type IV), DSA was less sensitive in defining nodule number and site. In the massive form, the information obtained with LCT and DSA was comparable. In conclusion, LCT should be considered a basic examination in the study of HCC extent. Based on LCT findings, the most appropriate treatment can be selected, be it surgery, alcohol injection, or intraarterial chemoembolization.

  9. Intravascular flow detection during transforaminal epidural injections: a prospective assessment.

    PubMed

    El Abd, Omar Hamman; Amadera, Joao Eduardo Daud; Pimentel, Daniel Camargo; Pimentel, Thais Spacov Camargo

    2014-01-01

    Transforaminal epidural steroid injections (TFESI) are a mainstay in the treatment of spine pain. Though this commonly performed procedure is generally felt to be safe, devastating complications following inadvertent intra-arterial injections of particulate steroid have been reported. The use of digital subtraction angiography (DSA) has been suggested as a means of detecting intra-arterial needle placements prior to medication injection. To examine the efficacy of DSA in detecting intra-arterial needle placements during TFESI. Prospective cohort study evaluating the impact of DSA on detecting intra-arterial needle placements during TFESI. We enrolled 150 consecutive patients presenting to a university-affiliated spine center with discogenic and/or radicular symptoms affecting the cervical, lumbar, and sacral regions. For each injection, prior to imaging with DSA, traditional methods for vascular penetration detection were employed, including the identification of blood in the needle hub (flash), negative aspiration of blood prior to injection, and live fluoroscopic injection of contrast. Once these tests were performed and negative for signs of intra-arterial needle placement, DSA imaging was utilized prior to medication administration for identification of vascular flow. A total number of 222 TFESI were performed, 41 injections at the cervical levels (18.47%), 113 at the lumbar levels (50.9%), and 68 at the sacral levels (30.36%). Flash was observed in 13 injections performed (5.85% of the total number of injections): one (0.45%) in the cervical, 2 (0.9%) in the lumbar, and 10 (4.5%) in the sacral levels. In 11 TFESI blood aspiration was obtained (4.95% of all injections): 3 (1.3%) in cervical, 4 (1.8%) in lumbar, and 4 (1.8%) in sacral injections. Live fluoroscopy during contrast injection detected 46 (20.72%) intravascular flow patterns: 7 (3.1%) cervical, 17 (7.6%) lumbar, and 22 (9.9%) sacral. DSA identified an additional 5 intravascular injections after all previous steps had resulted in negative vascular penetration signs, which accounted for 2.25% of all injections. This is a prospective, single-center study with a relatively small number of patients and no control group. DSA detected additional 5.26% intravascular needle placements following traditional methods. Our findings also support other studies that conclude TFESI are generally a safe procedure. We recommend that special attention should be paid to the sacral injections as vascular penetration was statistically higher than at other levels.

  10. Shape Analysis of Planar Multiply-Connected Objects Using Conformal Welding.

    PubMed

    Lok Ming Lui; Wei Zeng; Shing-Tung Yau; Xianfeng Gu

    2014-07-01

    Shape analysis is a central problem in the field of computer vision. In 2D shape analysis, classification and recognition of objects from their observed silhouettes are extremely crucial but difficult. It usually involves an efficient representation of 2D shape space with a metric, so that its mathematical structure can be used for further analysis. Although the study of 2D simply-connected shapes has been subject to a corpus of literatures, the analysis of multiply-connected shapes is comparatively less studied. In this work, we propose a representation for general 2D multiply-connected domains with arbitrary topologies using conformal welding. A metric can be defined on the proposed representation space, which gives a metric to measure dissimilarities between objects. The main idea is to map the exterior and interior of the domain conformally to unit disks and circle domains (unit disk with several inner disks removed), using holomorphic 1-forms. A set of diffeomorphisms of the unit circle S(1) can be obtained, which together with the conformal modules are used to define the shape signature. A shape distance between shape signatures can be defined to measure dissimilarities between shapes. We prove theoretically that the proposed shape signature uniquely determines the multiply-connected objects under suitable normalization. We also introduce a reconstruction algorithm to obtain shapes from their signatures. This completes our framework and allows us to move back and forth between shapes and signatures. With that, a morphing algorithm between shapes can be developed through the interpolation of the Beltrami coefficients associated with the signatures. Experiments have been carried out on shapes extracted from real images. Results demonstrate the efficacy of our proposed algorithm as a stable shape representation scheme.

  11. Solution of the within-group multidimensional discrete ordinates transport equations on massively parallel architectures

    NASA Astrophysics Data System (ADS)

    Zerr, Robert Joseph

    2011-12-01

    The integral transport matrix method (ITMM) has been used as the kernel of new parallel solution methods for the discrete ordinates approximation of the within-group neutron transport equation. The ITMM abandons the repetitive mesh sweeps of the traditional source iterations (SI) scheme in favor of constructing stored operators that account for the direct coupling factors among all the cells and between the cells and boundary surfaces. The main goals of this work were to develop the algorithms that construct these operators and employ them in the solution process, determine the most suitable way to parallelize the entire procedure, and evaluate the behavior and performance of the developed methods for increasing number of processes. This project compares the effectiveness of the ITMM with the SI scheme parallelized with the Koch-Baker-Alcouffe (KBA) method. The primary parallel solution method involves a decomposition of the domain into smaller spatial sub-domains, each with their own transport matrices, and coupled together via interface boundary angular fluxes. Each sub-domain has its own set of ITMM operators and represents an independent transport problem. Multiple iterative parallel solution methods have investigated, including parallel block Jacobi (PBJ), parallel red/black Gauss-Seidel (PGS), and parallel GMRES (PGMRES). The fastest observed parallel solution method, PGS, was used in a weak scaling comparison with the PARTISN code. Compared to the state-of-the-art SI-KBA with diffusion synthetic acceleration (DSA), this new method without acceleration/preconditioning is not competitive for any problem parameters considered. The best comparisons occur for problems that are difficult for SI DSA, namely highly scattering and optically thick. SI DSA execution time curves are generally steeper than the PGS ones. However, until further testing is performed it cannot be concluded that SI DSA does not outperform the ITMM with PGS even on several thousand or tens of thousands of processors. The PGS method does outperform SI DSA for the periodic heterogeneous layers (PHL) configuration problems. Although this demonstrates a relative strength/weakness between the two methods, the practicality of these problems is much less, further limiting instances where it would be beneficial to select ITMM over SI DSA. The results strongly indicate a need for a robust, stable, and efficient acceleration method (or preconditioner for PGMRES). The spatial multigrid (SMG) method is currently incomplete in that it does not work for all cases considered and does not effectively improve the convergence rate for all values of scattering ratio c or cell dimension h. Nevertheless, it does display the desired trend for highly scattering, optically thin problems. That is, it tends to lower the rate of growth of number of iterations with increasing number of processes, P, while not increasing the number of additional operations per iteration to the extent that the total execution time of the rapidly converging accelerated iterations exceeds that of the slower unaccelerated iterations. A predictive parallel performance model has been developed for the PBJ method. Timing tests were performed such that trend lines could be fitted to the data for the different components and used to estimate the execution times. Applied to the weak scaling results, the model notably underestimates construction time, but combined with a slight overestimation in iterative solution time, the model predicts total execution time very well for large P. It also does a decent job with the strong scaling results, closely predicting the construction time and time per iteration, especially as P increases. Although not shown to be competitive up to 1,024 processing elements with the current state of the art, the parallelized ITMM exhibits promising scaling trends. Ultimately, compared to the KBA method, the parallelized ITMM may be found to be a very attractive option for transport calculations spatially decomposed over several tens of thousands of processes. Acceleration/preconditioning of the parallelized ITMM once developed will improve the convergence rate and improve its competitiveness. (Abstract shortened by UMI.)

  12. Another Piece of the Antibody Puzzle: Observations from the HALT study\\.

    PubMed

    Snyder, Laurie D; Tinckam, Kathryn J

    2018-06-04

    In the rapidly evolving domain of clinical transplantation immunobiology, the interrogation and interpretation of HLA antibodies and their associated clinical consequences are in the spotlight. In lung transplant, HLA antibodies, in particular donor specific antibodies (DSA), are a determining component of the lung transplant antibody mediated rejection (AMR) definition (1). DSA after lung transplant are widely regarded as poor prognosticator, though sparse data to date necessitate ongoing discourse and continued investigation into incidence, timing and treatment. Prior studies reported a wide range of DSA incidence with differing consequences on a background of highly variable timing, methods, antibody analytic strategies and clinical definitions. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  13. Fourier mode analysis of slab-geometry transport iterations in spatially periodic media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larsen, E; Zika, M

    1999-04-01

    We describe a Fourier analysis of the diffusion-synthetic acceleration (DSA) and transport-synthetic acceleration (TSA) iteration schemes for a spatially periodic, but otherwise arbitrarily heterogeneous, medium. Both DSA and TSA converge more slowly in a heterogeneous medium than in a homogeneous medium composed of the volume-averaged scattering ratio. In the limit of a homogeneous medium, our heterogeneous analysis contains eigenvalues of multiplicity two at ''resonant'' wave numbers. In the presence of material heterogeneities, error modes corresponding to these resonant wave numbers are ''excited'' more than other error modes. For DSA and TSA, the iteration spectral radius may occur at these resonantmore » wave numbers, in which case the material heterogeneities most strongly affect iterative performance.« less

  14. An intelligent value-driven scheduling system for Space Station Freedom with special emphasis on the electric power system

    NASA Technical Reports Server (NTRS)

    Krupp, Joseph C.

    1991-01-01

    The Electric Power Control System (EPCS) created by Decision-Science Applications, Inc. (DSA) for the Lewis Research Center is discussed. This system makes decisions on what to schedule and when to schedule it, including making choices among various options or ways of performing a task. The system is goal-directed and seeks to shape resource usage in an optimal manner using a value-driven approach. Discussed here are considerations governing what makes a good schedule, how to design a value function to find the best schedule, and how to design the algorithm that finds the schedule that maximizes this value function. Results are shown which demonstrate the usefulness of the techniques employed.

  15. A quantum proxy group signature scheme based on an entangled five-qubit state

    NASA Astrophysics Data System (ADS)

    Wang, Meiling; Ma, Wenping; Wang, Lili; Yin, Xunru

    2015-09-01

    A quantum proxy group signature (QPGS) scheme based on controlled teleportation is presented, by using the entangled five-qubit quantum state functions as quantum channel. The scheme uses the physical characteristics of quantum mechanics to implement delegation, signature and verification. The security of the scheme is guaranteed by the entanglement correlations of the entangled five-qubit state, the secret keys based on the quantum key distribution (QKD) and the one-time pad algorithm, all of which have been proven to be unconditionally secure and the signature anonymity.

  16. Exploring the Use of Radar for Physically-Based Nowcasting of Lightning Cessation

    NASA Technical Reports Server (NTRS)

    Schultz, Elise V.; Petersen, Walter A.; Carey, Lawrence D.

    2011-01-01

    NASA's Marshall Space Flight Center and the University of Alabama in Huntsville (UAHuntsville) are collaborating with the 45th Weather Squadron (45WS) at Cape Canaveral Air Force Station (CCAFS) to enable improved nowcasting of lightning cessation. This project centers on use of dual-polarimetric radar capabilities, and in particular, the new C-band dual polarimetric weather radar acquired by the 45WS. Special emphasis is placed on the development of a physically-based operational algorithm to predict lightning cessation. While previous studies have developed statistically based lightning cessation algorithms driven primarily by trending in the actual total lightning flash rate, we believe that dual polarimetric radar variables offer the possibility to improve existing algorithms through the inclusion of physically meaningful trends reflecting interactions between in-cloud electric fields and ice-microphysics. Specifically, decades of polarimetric radar research using propagation differential phase has demonstrated the presence of distinct phase and ice crystal alignment signatures in the presence of strong electric fields associated with lightning. One question yet to be addressed is: To what extent can propagation phase-based ice-crystal alignment signatures be used to nowcast the cessation of lightning activity in a given storm? Accordingly, data from the UAHuntsville Advanced Radar for Meteorological and Operational Research (ARMOR) along with the NASA-MSFC North Alabama Lightning Mapping Array are used in this study to investigate the radar signatures present before and after lightning cessation. Thus far our case study results suggest that the negative differential phase shift signature weakens and disappears after the analyzed storms ceased lightning production (i.e., after the last lightning flash occurred). This is a key observation because it suggests that while strong electric fields may still have been present, the lightning cessation signature was encompassed in the period of the polarimetric negative phase shift signature. To the extent this behavior is repeatable in other cases, even if only in a substantial fraction of those cases, the analysis suggests that differential propagation phase may prove to be a useful parameter for future lightning cessation algorithms. Indeed, a preliminary analysis of 15+ cases has shown additional indications of the weakening and disappearance of this ice alignment signature with lightning cessation. A summary of these case-study results is presented.

  17. Non-Enhanced MR Imaging of Cerebral Arteriovenous Malformations at 7 Tesla.

    PubMed

    Wrede, Karsten H; Dammann, Philipp; Johst, Sören; Mönninghoff, Christoph; Schlamann, Marc; Maderwald, Stefan; Sandalcioglu, I Erol; Ladd, Mark E; Forsting, Michael; Sure, Ulrich; Umutlu, Lale

    2016-03-01

    To evaluate prospectively 7 Tesla time-of-flight (TOF) magnetic resonance angiography (MRA) and 7 Tesla non-contrast-enhanced magnetization-prepared rapid acquisition gradient-echo (MPRAGE) for delineation of intracerebral arteriovenous malformations (AVMs) in comparison to 1.5 Tesla TOF MRA and digital subtraction angiography (DSA). Twenty patients with single or multifocal AVMs were enrolled in this trial. The study protocol comprised 1.5 and 7 Tesla TOF MRA and 7 Tesla non-contrast-enhanced MPRAGE sequences. All patients underwent an additional four-vessel 3D DSA. Image analysis of the following five AVM features was performed individually by two radiologists on a five-point scale: nidus, feeder(s), draining vein(s), relationship to adjacent vessels, and overall image quality and presence of artefacts. A total of 21 intracerebral AVMs were detected. Both sequences at 7 Tesla were rated superior over 1.5 Tesla TOF MRA in the assessment of all considered AVM features. Image quality at 7 Tesla was comparable with DSA considering both sequences. Inter-observer accordance was good to excellent for the majority of ratings. This study demonstrates excellent image quality for depiction of intracerebral AVMs using non-contrast-enhanced 7 Tesla MRA, comparable with DSA. Assessment of untreated AVMs is a promising clinical application of ultra-high-field MRA. • Non-contrast-enhanced 7 Tesla MRA demonstrates excellent image quality for intracerebral AVM depiction. • Image quality at 7 Tesla was comparable with DSA considering both sequences. • Assessment of intracerebral AVMs is a promising clinical application of ultra-high-field MRA.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jens, Sjoerd, E-mail: s.jens@amc.uva.nl; Lucatelli, Pierleone, E-mail: pierleone.lucatelli@gmail.com; Koelemay, Mark J. W., E-mail: m.j.koelemaij@amc.uva.nl

    Purpose. To evaluate the additional value of three-dimensional rotational angiography (3DRA) of the foot compared with digital subtraction angiography (DSA) in patients with critical limb ischemia (CLI). Technique. For 3DRA, the C-arm was placed in the propeller position with the foot in an isocentric position. The patient's unaffected foot was positioned in a footrest outside the field of view. For correct timing of 3DRA, the delay from contrast injection in the popliteal artery at the level of knee joint to complete pedal arterial enhancement was assessed using DSA. With this delay, 3DRA was started after injection of 15 ml contrast.more » Imaging of the 3DRA could directly be reconstructed and visualized.Materials and MethodsPatients undergoing 3DRA of the foot were prospectively registered. DSA and 3DRA images were scored separately for arterial patency and presence of collaterals. Treatment strategies were proposed based on DSA with and without the availability of 3DRA. Results. Eleven patients underwent 3DRA of the foot. One 3DRA was not included because the acquisition was focused on the heel instead of the entire foot. Diagnostic quality of 3DRA was good in all ten patients. 3DRA compared with DSA showed additional patent arteries in six patients, patent plantar arch in three patients, and collaterals between the pedal arteries in five patients. Additional information from 3DRA resulted in a change of treatment strategy in six patients. Conclusion, 3DRA of the foot contains valuable additional real-time information to better guide peripheral vascular interventions in patients with CLI and nonhealing tissue lesions.« less

  19. The detection of NBOMe designer drugs on blotter paper by high resolution time-of-flight mass spectrometry (TOFMS) with and without chromatography.

    PubMed

    Botch-Jones, Sabra; Foss, Jamie; Barajas, David; Kero, Frank; Young, Craig; Weisenseel, Jason

    2016-10-01

    New psychoactive substances (NPS) have been associated with fatalities and severe injuries in a number of cases in the United States and have led investigators to rethink traditional drug monitoring protocols. Of particular interest are the variable phenethylamine chemical structures known as 'NBOMes', which pose an emerging threat to public health with incidence steadily growing over the past decade. In this study, direct sample analysis (DSA)-time of flight mass spectrometry was employed to leverage rapid and sensitive ambient ionization mass spectrometry without chromatographic separation as verified with an authentic case sample. Samples for method development were prepared at Boston University School of Medicine's Biomedical Forensic Sciences program (Boston, MA) and analyzed at the State of Maine Health and Environmental Testing Laboratory's Forensic Chemistry Section (Augusta, ME). Preliminary method development work was performed at the University of Central Florida (Orlando, FL). DSA without any extraction step in addition to the evaluation of methanol, dichloromethane and hexane extractions were conducted. Methanol was found to not be a suitable extraction solvent for DSA analysis of these compounds. For the screening of NBOMe designer drug variables on blotter paper, DSA-TOFMS was successful at reducing analysis time to ∼15s per sample, for qualitative identification for the selected analytes of interest. The analysis of an authentic forensic case sample by DSA-TOFMS using the method development parameters demonstrates its utility in forensic laboratories. 25C-NBOMe was identified with an exact mass accuracy of 0.60ppm. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Understanding Angiography-Based Aneurysm Flow Fields through Comparison with Computational Fluid Dynamics.

    PubMed

    Cebral, J R; Mut, F; Chung, B J; Spelle, L; Moret, J; van Nijnatten, F; Ruijters, D

    2017-06-01

    Hemodynamics is thought to be an important factor for aneurysm progression and rupture. Our aim was to evaluate whether flow fields reconstructed from dynamic angiography data can be used to realistically represent the main flow structures in intracranial aneurysms. DSA-based flow reconstructions, obtained during interventional treatment, were compared qualitatively with flow fields obtained from patient-specific computational fluid dynamics models and quantitatively with projections of the computational fluid dynamics fields (by computing a directional similarity of the vector fields) in 15 cerebral aneurysms. The average similarity between the DSA and the projected computational fluid dynamics flow fields was 78% in the parent artery, while it was only 30% in the aneurysm region. Qualitatively, both the DSA and projected computational fluid dynamics flow fields captured the location of the inflow jet, the main vortex structure, the intrasaccular flow split, and the main rotation direction in approximately 60% of the cases. Several factors affect the reconstruction of 2D flow fields from dynamic angiography sequences. The most important factors are the 3-dimensionality of the intrasaccular flow patterns and inflow jets, the alignment of the main vortex structure with the line of sight, the overlapping of surrounding vessels, and possibly frame rate undersampling. Flow visualization with DSA from >1 projection is required for understanding of the 3D intrasaccular flow patterns. Although these DSA-based flow quantification techniques do not capture swirling or secondary flows in the parent artery, they still provide a good representation of the mean axial flow and the corresponding flow rate. © 2017 by American Journal of Neuroradiology.

  1. Feasibility of intra-acquisition motion correction for 4D DSA reconstruction for applications in the thorax and abdomen

    NASA Astrophysics Data System (ADS)

    Wagner, Martin; Laeseke, Paul; Harari, Colin; Schafer, Sebastian; Speidel, Michael; Mistretta, Charles

    2018-03-01

    The recently proposed 4D DSA technique enables reconstruction of time resolved 3D volumes from two C-arm CT acquisitions. This provides information on the blood flow in neurovascular applications and can be used for the diagnosis and treatment of vascular diseases. For applications in the thorax and abdomen, respiratory motion can prevent successful 4D DSA reconstruction and cause severe artifacts. The purpose of this work is to propose a novel technique for motion compensated 4D DSA reconstruction to enable applications in the thorax and abdomen. The approach uses deformable 2D registration to align the projection images of a non-contrast and a contrast enhanced scan. A subset of projection images is then selected, which are acquired in a similar respiratory state and an iterative simultaneous multiplicative algebraic reconstruction is applied to determine a 3D constraint volume. A 2D-3D registration step then aligns the remaining projection images with the 3D constraint volume. Finally, a constrained back-projection is performed to create a 3D volume for each projection image. A pig study has been performed, where 4D DSA acquisitions were performed with and without respiratory motion to evaluate the feasibility of the approach. The dice similarity coefficient between the reference 3D constraint volume and the motion compensated reconstruction was 51.12 % compared to 35.99 % without motion compensation. This technique could improve the workflow for procedures in interventional radiology, e.g. liver embolizations, where changes in blood flow have to be monitored carefully.

  2. Analysis of Radiation Effects in Digital Subtraction Angiography of Intracranial Artery Stenosis.

    PubMed

    Guo, Chaoqun; Shi, Xiaolei; Ding, Xianhui; Zhou, Zhiming

    2018-04-21

    Intracranial artery stenosis (IAS) is the most common cause for acute cerebral accidents. Digital subtraction angiography (DSA) is the gold standard to detect IAS and usually brings excess radiation exposure to examinees and examiners. The artery pathology might influence the interventional procedure, causing prolonged radiation effects. However, no studies on the association between IAS pathology and operational parameters are available. A retrospective analysis was conducted on 93 patients with first-ever stroke/transient ischemic attack, who received DSA examination within 3 months from onset in this single center. Comparison of baseline characteristics was determined by 2-tailed Student's t-test or the chi-square test between subjects with and without IAS. A binary logistic regression analysis was performed to determine the association between IAS pathology and the items with a P value <0.05 in Student's t-test or chi-square test. There were 93 candidates (42 with IAS and 51 without IAS) in this study. The 2 groups shared no significance of the baseline characteristics (P > 0.05). We found a significantly higher total time, higher kerma area product, greater total dose, and greater DSA dose in the IAS group than in those without IAS (P < 0.05). A binary logistic regression analysis indicated the significant association between total time and IAS pathology (P < 0.05) but no significance in kerma area product, radiation dose, and DSA dose (P > 0.05). IAS pathology would indicate a prolonged total time of DSA procedure in clinical practice. However, the radiation effects would not change with pathologic changes. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Seismic and acoustic signal identification algorithms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LADD,MARK D.; ALAM,M. KATHLEEN; SLEEFE,GERARD E.

    2000-04-03

    This paper will describe an algorithm for detecting and classifying seismic and acoustic signals for unattended ground sensors. The algorithm must be computationally efficient and continuously process a data stream in order to establish whether or not a desired signal has changed state (turned-on or off). The paper will focus on describing a Fourier based technique that compares the running power spectral density estimate of the data to a predetermined signature in order to determine if the desired signal has changed state. How to establish the signature and the detection thresholds will be discussed as well as the theoretical statisticsmore » of the algorithm for the Gaussian noise case with results from simulated data. Actual seismic data results will also be discussed along with techniques used to reduce false alarms due to the inherent nonstationary noise environments found with actual data.« less

  4. The BHEF National Higher Education and Workforce Initiative: A Model for Pathways to Baccalaureate Attainment and High-Skill Careers in Emerging Fields, Part 3

    ERIC Educational Resources Information Center

    Fitzgerald, Brian K.; Barkanic, Steve; Cárdenas-Navia, Isabel; Chen, Janet; Elzey, Karen; Hughes, Debbie; Troyan, Danielle

    2016-01-01

    BHEF has achieved particular success in operationalizing its National Higher Education and Workforce Initiative (HEWI) through regional initiatives in data science and analytics (DSA). Leveraging its membership of corporate CEOs, university presidents and government agency leaders, BHEF seeded new undergraduate pathways in DSA at Case Western…

  5. IBM’s PIQUANT in TREC2003

    DTIC Science & Technology

    2003-01-01

    La Bomba ,’’ ( the bomb ) for his explosive skiing style DSA P11 work: La Bomba LQA P12 most successful and popular Italian skier ever DSA P11...Alberto Tomba , Italy LQA P2 lawyer SQA job: champion LQA P6 work: Slalom for Peace LQA P12 born: Italy LQA P2 work: the Bomba LQA P12 some World Cup

  6. Mesa redonda: Argentina en proyectos globales de investigaciones espaciales y astronómicas. Uso científico de la Antena de Espacio Profundo DSA 3

    NASA Astrophysics Data System (ADS)

    Colazo, M.

    2016-08-01

    Argentine has 10 percent of the operative time available for the DSA 3 Antenna of the European Space Agency, installed in Malargüe, Mendoza. Here we present the history of the project and the current activities for the scientific use of the antenna.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cavagna, Enrico; D'Andrea, Paolo; Schiavon, Francesco

    Purpose: To evaluate failing hemodialysis arteriovenous fistulas with helical CT angiography (CTA), MR angiography (MRA), and digital subtraction angiography (DSA), and to compare the efficacy of the three techniques in detecting the number, location, grade, and extent of stenoses and in assessing the technical results of percutaneous transluminal angioplasty (PTA) and stenting.Methods: Thirteen patients with Brescia-Cimino arteriovenous fistula malfunction underwent MRA and CTA of the fistula and, within 1 week, DSA. A total of 11 PTAs were performed; in three cases an MR-compatible stent was placed. DSA served as the gold standard for comparison in all patients. The presence, site,more » and number of stenoses or occlusions and the technical results of percutaneous procedures were assessed with DSA, CTA, and MRA.Results: MRA underestimated a single stenosis in one patient; CTA and MRA did not overestimate any stenosis. Significant artifacts related to stent geometry and/or underlying metal were seen in MRA sequences in two cases.Conclusions: CT and MRI can provide information regarding the degree of vascular impairment, helping to stratify patients into those who can have PTA (single or multiple stenoses) versus those who require an operative procedure (occlusion). Conventional angiography can be reserved for candidates for percutaneous intervention.« less

  8. Recent Advances in Allograft Vasculopathy

    PubMed Central

    Merola, Jonathan; Jane-Wit, Daniel D.; Pober, Jordan S.

    2017-01-01

    Purpose of review Despite considerable advances in controlling acute rejection, the longevity of cardiac and renal allografts remains significantly limited by chronic rejection in the form of allograft vasculopathy (AV). This review discusses recently reported mechanistic insights of AV pathogenesis as well recent clinical evaluations of new therapeutic approaches. Recent findings Although adaptive immunity is the major driver of AV, natural killer cells mediate vasculopathic changes in a transplanted mouse heart following treatment with donor-specific antibody (DSA). However, NK cells may also dampen chronic inflammatory responses by killing donor-derived tissue-resident CD4 T cells that provide help to host B cells, the source of DSA. DSA may directly contribute to vascular inflammation by inducing intracellular signaling cascades that upregulate leukocyte adhesion molecules, facilitating recruitment of neutrophils and monocytes. DSA-mediated complement activation additionally enhances endothelial alloimmunogenicity through activation of non-canonical NF-κB signaling. New clinical studies evaluating mTOR and proteasome inhibitors to target these pathways have been reported. Summary AV is a pathology resultant from several innate and adaptive alloimmune responses. Mechanistic insights from preclinical studies have identified agents that are currently being investigated in clinical trials. PMID:27898462

  9. Customization and design of directed self-assembly using hybrid prepatterns

    NASA Astrophysics Data System (ADS)

    Cheng, Joy; Doerk, Gregory S.; Rettner, Charles T.; Singh, Gurpreet; Tjio, Melia; Truong, Hoa; Arellano, Noel; Balakrishnan, Srinivasan; Brink, Markus; Tsai, Hsinyu; Liu, Chi-Chun; Guillorn, Michael; Sanders, Daniel P.

    2015-03-01

    Diminishing error tolerance renders the customization of patterns created through directed self-assembly (DSA) extremely challenging at tighter pitch. A self-aligned customization scheme can be achieved using a hybrid prepattern comprising both organic and inorganic regions that serves as a guiding prepattern to direct the self-assembly of the block copolymers as well as a cut mask pattern for the DSA arrays aligned to it. In this paper, chemoepitaxy-based self-aligned customization is demonstrated using two types of organic-inorganic prepatterns. CHEETAH prepattern for "CHemoepitaxy Etch Trim using a self-Aligned Hardmask" of preferential hydrogen silsesquioxane (HSQ, inorganic resist), non-preferential organic underlayer is fabricated using electron beam lithography. Customized trench or hole arrays can be achieved through co-transfer of DSA-formed arrays and CHEETAH prepattern. Herein, we also introduce a tone-reversed version called reverse-CHEETAH (or rCHEETAH) in which customized line segments can be achieved through co-transfer of DSA-formed arrays formed on a prepattern wherein the inorganic HSQ regions are nonpreferential and the organic regions are PMMA preferential. Examples of two-dimensional self-aligned customization including 25nm pitch fin structures and an 8-bar "IBM" illustrate the versatility of this customization scheme using rCHEETAH.

  10. 3D printing of intracranial aneurysm based on intracranial digital subtraction angiography and its clinical application.

    PubMed

    Wang, Jian-Li; Yuan, Zi-Gang; Qian, Guo-Liang; Bao, Wu-Qiao; Jin, Guo-Liang

    2018-06-01

    The study aimed to develop simulation models including intracranial aneurysmal and parent vessel geometries, as well as vascular branches, through 3D printing technology. The simulation models focused on the benefits of aneurysmal treatments and clinical education. This prospective study included 13 consecutive patients who suffered from intracranial aneurysms confirmed by digital subtraction angiography (DSA) in the Neurosurgery Department of Shaoxing People's Hospital. The original 3D-DSA image data were extracted through the picture archiving and communication system and imported into Mimics. After reconstructing and transforming to Binary STL format, the simulation models of the hollow vascular tree were printed using 3D devices. The intracranial aneurysm 3D printing simulation model was developed based on DSA to assist neurosurgeons in aneurysmal treatments and residency training. Seven neurosurgical residents and 15 standardization training residents received their simulation model training and gave high assessments for the educational course with the follow-up qualitative questionnaire. 3D printed simulation models based on DSA can perfectly reveal target aneurysms and help neurosurgeons select therapeutic strategies precisely. As an educational tool, the 3D aneurysm vascular simulation model is useful for training residents.

  11. 64-slice MDCT angiography of upper extremity in assessment of native hemodialysis access.

    PubMed

    Wasinrat, Jitladda; Siriapisith, Thanongchai; Thamtorawat, Somrach; Tongdee, Trongtum

    2011-01-01

    To compare multidetector row computed tomographic (MDCT) angiography with conventional digital subtraction angiography (DSA) in the evaluation of vascular access stenoses in hemodialysis patients. Twenty-one consecutive patients were imaged with MDCT angiography and subsequent DSA. The superficial vein of leg was used as the route for intravenous administration. The vascular stenosis was assessed in not significant (<50% stenosis), moderate stenosis (50%-74% stenosis), severe stenosis (75%-99%), and total occlusion (100%). The accuracy, sensitivity, specificity, positive, and negative predictive values were calculated for significant vascular stenosis using DSA as the standard reference. The sensitivity and specificity of MDCT angiography for the detection of significant hemodialysis vascular access were 100% (95% CI, 89.3%-100%) and 94.8% (95% CI, 89.1%-97.6%), respectively. The positive and negative predictive values were 84.2% (95% CI, 68.1%-93.4%) and 100% (95% CI, 95.8%-100%), respectively. The accuracy of MDCT angiography for detection of significant stenoses was 95.9% (95% CI, 91.4%-97.0%). MDCT angiography provides excellent correlation in vascular stenosis as compared with DSA in hemodialysis access. Complete assessment of entire vascular segments could be performing with MDCT angiography in planning before endovascular intervention or surgical correction.

  12. Thermal imaging as a biometrics approach to facial signature authentication.

    PubMed

    Guzman, A M; Goryawala, M; Wang, Jin; Barreto, A; Andrian, J; Rishe, N; Adjouadi, M

    2013-01-01

    A new thermal imaging framework with unique feature extraction and similarity measurements for face recognition is presented. The research premise is to design specialized algorithms that would extract vasculature information, create a thermal facial signature and identify the individual. The proposed algorithm is fully integrated and consolidates the critical steps of feature extraction through the use of morphological operators, registration using the Linear Image Registration Tool and matching through unique similarity measures designed for this task. The novel approach at developing a thermal signature template using four images taken at various instants of time ensured that unforeseen changes in the vasculature over time did not affect the biometric matching process as the authentication process relied only on consistent thermal features. Thirteen subjects were used for testing the developed technique on an in-house thermal imaging system. The matching using the similarity measures showed an average accuracy of 88.46% for skeletonized signatures and 90.39% for anisotropically diffused signatures. The highly accurate results obtained in the matching process clearly demonstrate the ability of the thermal infrared system to extend in application to other thermal imaging based systems. Empirical results applying this approach to an existing database of thermal images proves this assertion.

  13. Genome signature analysis of thermal virus metagenomes reveals Archaea and thermophilic signatures

    PubMed Central

    Pride, David T; Schoenfeld, Thomas

    2008-01-01

    Background Metagenomic analysis provides a rich source of biological information for otherwise intractable viral communities. However, study of viral metagenomes has been hampered by its nearly complete reliance on BLAST algorithms for identification of DNA sequences. We sought to develop algorithms for examination of viral metagenomes to identify the origin of sequences independent of BLAST algorithms. We chose viral metagenomes obtained from two hot springs, Bear Paw and Octopus, in Yellowstone National Park, as they represent simple microbial populations where comparatively large contigs were obtained. Thermal spring metagenomes have high proportions of sequences without significant Genbank homology, which has hampered identification of viruses and their linkage with hosts. To analyze each metagenome, we developed a method to classify DNA fragments using genome signature-based phylogenetic classification (GSPC), where metagenomic fragments are compared to a database of oligonucleotide signatures for all previously sequenced Bacteria, Archaea, and viruses. Results From both Bear Paw and Octopus hot springs, each assembled contig had more similarity to other metagenome contigs than to any sequenced microbial genome based on GSPC analysis, suggesting a genome signature common to each of these extreme environments. While viral metagenomes from Bear Paw and Octopus share some similarity, the genome signatures from each locale are largely unique. GSPC using a microbial database predicts most of the Octopus metagenome has archaeal signatures, while bacterial signatures predominate in Bear Paw; a finding consistent with those of Genbank BLAST. When using a viral database, the majority of the Octopus metagenome is predicted to belong to archaeal virus Families Globuloviridae and Fuselloviridae, while none of the Bear Paw metagenome is predicted to belong to archaeal viruses. As expected, when microbial and viral databases are combined, each of the Octopus and Bear Paw metagenomic contigs are predicted to belong to viruses rather than to any Bacteria or Archaea, consistent with the apparent viral origin of both metagenomes. Conclusion That BLAST searches identify no significant homologs for most metagenome contigs, while GSPC suggests their origin as archaeal viruses or bacteriophages, indicates GSPC provides a complementary approach in viral metagenomic analysis. PMID:18798991

  14. Genome signature analysis of thermal virus metagenomes reveals Archaea and thermophilic signatures.

    PubMed

    Pride, David T; Schoenfeld, Thomas

    2008-09-17

    Metagenomic analysis provides a rich source of biological information for otherwise intractable viral communities. However, study of viral metagenomes has been hampered by its nearly complete reliance on BLAST algorithms for identification of DNA sequences. We sought to develop algorithms for examination of viral metagenomes to identify the origin of sequences independent of BLAST algorithms. We chose viral metagenomes obtained from two hot springs, Bear Paw and Octopus, in Yellowstone National Park, as they represent simple microbial populations where comparatively large contigs were obtained. Thermal spring metagenomes have high proportions of sequences without significant Genbank homology, which has hampered identification of viruses and their linkage with hosts. To analyze each metagenome, we developed a method to classify DNA fragments using genome signature-based phylogenetic classification (GSPC), where metagenomic fragments are compared to a database of oligonucleotide signatures for all previously sequenced Bacteria, Archaea, and viruses. From both Bear Paw and Octopus hot springs, each assembled contig had more similarity to other metagenome contigs than to any sequenced microbial genome based on GSPC analysis, suggesting a genome signature common to each of these extreme environments. While viral metagenomes from Bear Paw and Octopus share some similarity, the genome signatures from each locale are largely unique. GSPC using a microbial database predicts most of the Octopus metagenome has archaeal signatures, while bacterial signatures predominate in Bear Paw; a finding consistent with those of Genbank BLAST. When using a viral database, the majority of the Octopus metagenome is predicted to belong to archaeal virus Families Globuloviridae and Fuselloviridae, while none of the Bear Paw metagenome is predicted to belong to archaeal viruses. As expected, when microbial and viral databases are combined, each of the Octopus and Bear Paw metagenomic contigs are predicted to belong to viruses rather than to any Bacteria or Archaea, consistent with the apparent viral origin of both metagenomes. That BLAST searches identify no significant homologs for most metagenome contigs, while GSPC suggests their origin as archaeal viruses or bacteriophages, indicates GSPC provides a complementary approach in viral metagenomic analysis.

  15. Influence Of Momentum Excess On The Pattern And Dynamics Of Intermediate-Range Stratified Wakes

    DTIC Science & Technology

    2016-06-01

    excess in order to model the fundamental differences between signatures generated by towed and self- propelled bodies in various ocean states. In cases...which can be used on the operational level for developing and improving algorithms for non- acoustic signature prediction and detection. 14. SUBJECT...order to model the fundamental differences between signatures generated by towed and self- propelled bodies in various ocean states. In cases where

  16. GESearch: An Interactive GUI Tool for Identifying Gene Expression Signature.

    PubMed

    Ye, Ning; Yin, Hengfu; Liu, Jingjing; Dai, Xiaogang; Yin, Tongming

    2015-01-01

    The huge amount of gene expression data generated by microarray and next-generation sequencing technologies present challenges to exploit their biological meanings. When searching for the coexpression genes, the data mining process is largely affected by selection of algorithms. Thus, it is highly desirable to provide multiple options of algorithms in the user-friendly analytical toolkit to explore the gene expression signatures. For this purpose, we developed GESearch, an interactive graphical user interface (GUI) toolkit, which is written in MATLAB and supports a variety of gene expression data files. This analytical toolkit provides four models, including the mean, the regression, the delegate, and the ensemble models, to identify the coexpression genes, and enables the users to filter data and to select gene expression patterns by browsing the display window or by importing knowledge-based genes. Subsequently, the utility of this analytical toolkit is demonstrated by analyzing two sets of real-life microarray datasets from cell-cycle experiments. Overall, we have developed an interactive GUI toolkit that allows for choosing multiple algorithms for analyzing the gene expression signatures.

  17. Age and gender-invariant features of handwritten signatures for verification systems

    NASA Astrophysics Data System (ADS)

    AbdAli, Sura; Putz-Leszczynska, Joanna

    2014-11-01

    Handwritten signature is one of the most natural biometrics, the study of human physiological and behavioral patterns. Behavioral biometrics includes signatures that may be different due to its owner gender or age because of intrinsic or extrinsic factors. This paper presents the results of the author's research on age and gender influence on verification factors. The experiments in this research were conducted using a database that contains signatures and their associated metadata. The used algorithm is based on the universal forgery feature idea, where the global classifier is able to classify a signature as a genuine one or, as a forgery, without the actual knowledge of the signature template and its owner. Additionally, the reduction of the dimensionality with the MRMR method is discussed.

  18. Target discrimination of man-made objects using passive polarimetric signatures acquired in the visible and infrared spectral bands

    NASA Astrophysics Data System (ADS)

    Lavigne, Daniel A.; Breton, Mélanie; Fournier, Georges; Charette, Jean-François; Pichette, Mario; Rivet, Vincent; Bernier, Anne-Pier

    2011-10-01

    Surveillance operations and search and rescue missions regularly exploit electro-optic imaging systems to detect targets of interest in both the civilian and military communities. By incorporating the polarization of light as supplementary information to such electro-optic imaging systems, it is possible to increase their target discrimination capabilities, considering that man-made objects are known to depolarized light in different manner than natural backgrounds. As it is known that electro-magnetic radiation emitted and reflected from a smooth surface observed near a grazing angle becomes partially polarized in the visible and infrared wavelength bands, additional information about the shape, roughness, shading, and surface temperatures of difficult targets can be extracted by processing effectively such reflected/emitted polarized signatures. This paper presents a set of polarimetric image processing algorithms devised to extract meaningful information from a broad range of man-made objects. Passive polarimetric signatures are acquired in the visible, shortwave infrared, midwave infrared, and longwave infrared bands using a fully automated imaging system developed at DRDC Valcartier. A fusion algorithm is used to enable the discrimination of some objects lying in shadowed areas. Performance metrics, derived from the computed Stokes parameters, characterize the degree of polarization of man-made objects. Field experiments conducted during winter and summer time demonstrate: 1) the utility of the imaging system to collect polarized signatures of different objects in the visible and infrared spectral bands, and 2) the enhanced performance of target discrimination and fusion algorithms to exploit the polarized signatures of man-made objects against cluttered backgrounds.

  19. Improvements in estimating proportions of objects from multispectral data

    NASA Technical Reports Server (NTRS)

    Horwitz, H. M.; Hyde, P. D.; Richardson, W.

    1974-01-01

    Methods for estimating proportions of objects and materials imaged within the instantaneous field of view of a multispectral sensor were developed further. Improvements in the basic proportion estimation algorithm were devised as well as improved alien object detection procedures. Also, a simplified signature set analysis scheme was introduced for determining the adequacy of signature set geometry for satisfactory proportion estimation. Averaging procedures used in conjunction with the mixtures algorithm were examined theoretically and applied to artificially generated multispectral data. A computationally simpler estimator was considered and found unsatisfactory. Experiments conducted to find a suitable procedure for setting the alien object threshold yielded little definitive result. Mixtures procedures were used on a limited amount of ERTS data to estimate wheat proportion in selected areas. Results were unsatisfactory, partly because of the ill-conditioned nature of the pure signature set.

  20. Comparison of Neural Networks and Tabular Nearest Neighbor Encoding for Hyperspectral Signature Classification in Unresolved Object Detection

    NASA Astrophysics Data System (ADS)

    Schmalz, M.; Ritter, G.; Key, R.

    Accurate and computationally efficient spectral signature classification is a crucial step in the nonimaging detection and recognition of spaceborne objects. In classical hyperspectral recognition applications using linear mixing models, signature classification accuracy depends on accurate spectral endmember discrimination [1]. If the endmembers cannot be classified correctly, then the signatures cannot be classified correctly, and object recognition from hyperspectral data will be inaccurate. In practice, the number of endmembers accurately classified often depends linearly on the number of inputs. This can lead to potentially severe classification errors in the presence of noise or densely interleaved signatures. In this paper, we present an comparison of emerging technologies for nonimaging spectral signature classfication based on a highly accurate, efficient search engine called Tabular Nearest Neighbor Encoding (TNE) [3,4] and a neural network technology called Morphological Neural Networks (MNNs) [5]. Based on prior results, TNE can optimize its classifier performance to track input nonergodicities, as well as yield measures of confidence or caution for evaluation of classification results. Unlike neural networks, TNE does not have a hidden intermediate data structure (e.g., the neural net weight matrix). Instead, TNE generates and exploits a user-accessible data structure called the agreement map (AM), which can be manipulated by Boolean logic operations to effect accurate classifier refinement algorithms. The open architecture and programmability of TNE's agreement map processing allows a TNE programmer or user to determine classification accuracy, as well as characterize in detail the signatures for which TNE did not obtain classification matches, and why such mis-matches occurred. In this study, we will compare TNE and MNN based endmember classification, using performance metrics such as probability of correct classification (Pd) and rate of false detections (Rfa). As proof of principle, we analyze classification of multiple closely spaced signatures from a NASA database of space material signatures. Additional analysis pertains to computational complexity and noise sensitivity, which are superior to Bayesian techniques based on classical neural networks. [1] Winter, M.E. "Fast autonomous spectral end-member determination in hyperspectral data," in Proceedings of the 13th International Conference On Applied Geologic Remote Sensing, Vancouver, B.C., Canada, pp. 337-44 (1999). [2] N. Keshava, "A survey of spectral unmixing algorithms," Lincoln Laboratory Journal 14:55-78 (2003). [3] Key, G., M.S. SCHMALZ, F.M. Caimi, and G.X. Ritter. "Performance analysis of tabular nearest neighbor encoding algorithm for joint compression and ATR", in Proceedings SPIE 3814:115-126 (1999). [4] Schmalz, M.S. and G. Key. "Algorithms for hyperspectral signature classification in unresolved object detection using tabular nearest neighbor encoding" in Proceedings of the 2007 AMOS Conference, Maui HI (2007). [5] Ritter, G.X., G. Urcid, and M.S. Schmalz. "Autonomous single-pass endmember approximation using lattice auto-associative memories", Neurocomputing (Elsevier), accepted (June 2008).

  1. Large Scale Assessment of Radio Frequency Interference Signatures in L-band SAR Data

    NASA Astrophysics Data System (ADS)

    Meyer, F. J.; Nicoll, J.

    2011-12-01

    Imagery of L-band Synthetic Aperture Radar (SAR) systems such as the PALSAR sensor on board the Advanced Land Observing Satellite (ALOS) has proven to be a valuable tool for observing environmental changes around the globe. Besides offering 24/7 operability, the L-band frequency provides improved interferometric coherence, and L-band polarimetric data has shown great potential for vegetation monitoring, sea ice classification, and the observation of glaciers and ice sheets. To maximize the benefit of missions such as ALOS PALSAR for environmental monitoring, data consistency and calibration are vital. Unfortunately, radio frequency interference (RFI) signatures from ground-based radar systems regularly impair L-band SAR data quality and consistency. With this study we present a large-scale analysis of typical RFI signatures that are regularly observed in L-band SAR data over the Americas. Through a study of the vast archive of L-band SAR data in the US Government Research Consortium (USGRC) data pool at the Alaska Satellite Facility (ASF) we were able to address the following research goals: 1. Assessment of RFI Signatures in L-band SAR data and their Effects on SAR Data Quality: An analysis of time-frequency properties of RFI signatures in L-band SAR data of the USGRC data pool is presented. It is shown that RFI-filtering algorithms implemented in the operational ALOS PALSAR processor are not sufficient to remove all RFI-related artifacts. In examples, the deleterious effects of RFI on SAR image quality, polarimetric signature, SAR phase, and interferometric coherence are presented. 2. Large-Scale Assessment of Severity, Spatial Distribution, and Temporal Variation of RFI Signatures in L-band SAR data: L-band SAR data in the USGRC data pool were screened for RFI using a custom algorithm. Per SAR frame, the algorithm creates geocoded frame bounding boxes that are color-coded according to RFI intensity and converted to KML files for analysis in Google Earth. From the screening results, parameters such as RFI severity and spatial distribution of RFI were derived. Through a comparison of RFI signatures in older SAR data from JAXA's Japanese Earth Resources Satellite (JERS-1) and recent ALOS PALSAR data, changes in RFI signatures in the Americas were derived, indicating a strong increase of L-band signal contamination over time. 3. An Optimized RFI Filter and its Performance in Data Restoration: An optimized RFI filter has been developed and tested at ASF. The algorithm has proven to be effective in detecting and removing RFI signatures in L-band SAR data and restoring the advertised quality of SAR imagery, polarization, and interferometric phase. The properties of the RFI filter will be described and its performance will be demonstrated in examples. The presented work is a prime example of large-scale research that is made possible by the availability of SAR data through the extensive data archive of the USGRC data pool at ASF.

  2. Adaptive Aft Signature Shaping of a Low-Boom Supersonic Aircraft Using Off-Body Pressures

    NASA Technical Reports Server (NTRS)

    Ordaz, Irian; Li, Wu

    2012-01-01

    The design and optimization of a low-boom supersonic aircraft using the state-of-the- art o -body aerodynamics and sonic boom analysis has long been a challenging problem. The focus of this paper is to demonstrate an e ective geometry parameterization scheme and a numerical optimization approach for the aft shaping of a low-boom supersonic aircraft using o -body pressure calculations. A gradient-based numerical optimization algorithm that models the objective and constraints as response surface equations is used to drive the aft ground signature toward a ramp shape. The design objective is the minimization of the variation between the ground signature and the target signature subject to several geometric and signature constraints. The target signature is computed by using a least-squares regression of the aft portion of the ground signature. The parameterization and the deformation of the geometry is performed with a NASA in- house shaping tool. The optimization algorithm uses the shaping tool to drive the geometric deformation of a horizontal tail with a parameterization scheme that consists of seven camber design variables and an additional design variable that describes the spanwise location of the midspan section. The demonstration cases show that numerical optimization using the state-of-the-art o -body aerodynamic calculations is not only feasible and repeatable but also allows the exploration of complex design spaces for which a knowledge-based design method becomes less effective.

  3. DEMON-type algorithms for determination of hydro-acoustic signatures of surface ships and of divers

    NASA Astrophysics Data System (ADS)

    Slamnoiu, G.; Radu, O.; Rosca, V.; Pascu, C.; Damian, R.; Surdu, G.; Curca, E.; Radulescu, A.

    2016-08-01

    With the project “System for detection, localization, tracking and identification of risk factors for strategic importance in littoral areas”, developed in the National Programme II, the members of the research consortium intend to develop a functional model for a hydroacoustic passive subsystem for determination of acoustic signatures of targets such as fast boats and autonomous divers. This paper presents some of the results obtained in the area of hydroacoustic signal processing by using DEMON-type algorithms (Detection of Envelope Modulation On Noise). For evaluation of the performance of various algorithm variations we have used both audio recordings of the underwater noise generated by ships and divers in real situations and also simulated noises. We have analysed the results of processing these signals using four DEMON algorithm structures as presented in the reference literature and a fifth DEMON algorithm structure proposed by the authors of this paper. The algorithm proposed by the authors generates similar results to those obtained by applying the traditional algorithms but requires less computing resources than those and at the same time it has proven to be more resilient to random noise influence.

  4. Application of stochastic weighted algorithms to a multidimensional silica particle model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menz, William J.; Patterson, Robert I.A.; Wagner, Wolfgang

    2013-09-01

    Highlights: •Stochastic weighted algorithms (SWAs) are developed for a detailed silica model. •An implementation of SWAs with the transition kernel is presented. •The SWAs’ solutions converge to the direct simulation algorithm’s (DSA) solution. •The efficiency of SWAs is evaluated for this multidimensional particle model. •It is shown that SWAs can be used for coagulation problems in industrial systems. -- Abstract: This paper presents a detailed study of the numerical behaviour of stochastic weighted algorithms (SWAs) using the transition regime coagulation kernel and a multidimensional silica particle model. The implementation in the SWAs of the transition regime coagulation kernel and associatedmore » majorant rates is described. The silica particle model of Shekar et al. [S. Shekar, A.J. Smith, W.J. Menz, M. Sander, M. Kraft, A multidimensional population balance model to describe the aerosol synthesis of silica nanoparticles, Journal of Aerosol Science 44 (2012) 83–98] was used in conjunction with this coagulation kernel to study the convergence properties of SWAs with a multidimensional particle model. High precision solutions were calculated with two SWAs and also with the established direct simulation algorithm. These solutions, which were generated using large number of computational particles, showed close agreement. It was thus demonstrated that SWAs can be successfully used with complex coagulation kernels and high dimensional particle models to simulate real-world systems.« less

  5. Security authentication using phase-encoded nanoparticle structures and polarized light.

    PubMed

    Carnicer, Artur; Hassanfiroozi, Amir; Latorre-Carmona, Pedro; Huang, Yi-Pai; Javidi, Bahram

    2015-01-15

    Phase-encoded nanostructures such as quick response (QR) codes made of metallic nanoparticles are suggested to be used in security and authentication applications. We present a polarimetric optical method able to authenticate random phase-encoded QR codes. The system is illuminated using polarized light, and the QR code is encoded using a phase-only random mask. Using classification algorithms, it is possible to validate the QR code from the examination of the polarimetric signature of the speckle pattern. We used Kolmogorov-Smirnov statistical test and Support Vector Machine algorithms to authenticate the phase-encoded QR codes using polarimetric signatures.

  6. 34 CFR 367.11 - What assurances must a DSA include in its application?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... State plan under section 704 of the Act any new methods and approaches relating to IL services for older... expended only for the purposes described in § 367.1; (b) With respect to the costs of the program to be... be effective; (d) At the end of each fiscal year, the DSA will prepare and submit to the Secretary a...

  7. 34 CFR 367.11 - What assurances must a DSA include in its application?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... State plan under section 704 of the Act any new methods and approaches relating to IL services for older... expended only for the purposes described in § 367.1; (b) With respect to the costs of the program to be... be effective; (d) At the end of each fiscal year, the DSA will prepare and submit to the Secretary a...

  8. A Case Study: Analyzing City Vitality with Four Pillars of Activity-Live, Work, Shop, and Play.

    PubMed

    Griffin, Matt; Nordstrom, Blake W; Scholes, Jon; Joncas, Kate; Gordon, Patrick; Krivenko, Elliott; Haynes, Winston; Higdon, Roger; Stewart, Elizabeth; Kolker, Natali; Montague, Elizabeth; Kolker, Eugene

    2016-03-01

    This case study evaluates and tracks vitality of a city (Seattle), based on a data-driven approach, using strategic, robust, and sustainable metrics. This case study was collaboratively conducted by the Downtown Seattle Association (DSA) and CDO Analytics teams. The DSA is a nonprofit organization focused on making the city of Seattle and its Downtown a healthy and vibrant place to Live, Work, Shop, and Play. DSA primarily operates through public policy advocacy, community and business development, and marketing. In 2010, the organization turned to CDO Analytics ( cdoanalytics.org ) to develop a process that can guide and strategically focus DSA efforts and resources for maximal benefit to the city of Seattle and its Downtown. CDO Analytics was asked to develop clear, easily understood, and robust metrics for a baseline evaluation of the health of the city, as well as for ongoing monitoring and comparisons of the vitality, sustainability, and growth. The DSA and CDO Analytics teams strategized on how to effectively assess and track the vitality of Seattle and its Downtown. The two teams filtered a variety of data sources, and evaluated the veracity of multiple diverse metrics. This iterative process resulted in the development of a small number of strategic, simple, reliable, and sustainable metrics across four pillars of activity: Live, Work, Shop, and Play. Data during the 5 years before 2010 were used for the development of the metrics and model and its training, and data during the 5 years from 2010 and on were used for testing and validation. This work enabled DSA to routinely track these strategic metrics, use them to monitor the vitality of Downtown Seattle, prioritize improvements, and identify new value-added programs. As a result, the four-pillar approach became an integral part of the data-driven decision-making and execution of the Seattle community's improvement activities. The approach described in this case study is actionable, robust, inexpensive, and easy to adopt and sustain. It can be applied to cities, districts, counties, regions, states, or countries, enabling cross-comparisons and improvements of vitality, sustainability, and growth.

  9. Carotid DSA based CFD simulation in assessing the patient with asymptomatic carotid stenosis: a preliminary study.

    PubMed

    Zhang, Dong; Xu, Pengcheng; Qiao, Hongyu; Liu, Xin; Luo, Liangping; Huang, Wenhua; Zhang, Heye; Shi, Changzheng

    2018-03-12

    Cerebrovascular events are frequently associated with hemodynamic disturbance caused by internal carotid artery (ICA) stenosis. It is challenging to determine the ischemia-related carotid stenosis during the intervention only using digital subtracted angiography (DSA). Inspired by the performance of well-established FFRct technique in hemodynamic assessment of significant coronary stenosis, we introduced a pressure-based carotid arterial functional assessment (CAFA) index generated from computational fluid dynamic (CFD) simulation in DSA data, and investigated its feasibility in the assessment of hemodynamic disturbance preliminarily using pressure-wired measurement and arterial spin labeling (ASL) MRI as references. The cerebral multi-delay multi-parametric ASL-MRI and carotid DSA including trans-stenotic pressure-wired measurement were implemented on a 65-year-old man with asymptomatic unilateral (left) ICA stenosis. A CFD simulation using simplified boundary condition was performed in DSA data to calculate the CAFA index. The cerebral blood flow (CBF) and arterial transit time (ATT) of ICA territories were acquired. CFD simulation showed good correlation (r = 0.839, P = 0.001) with slight systematic overestimation (mean difference - 0.007, standard deviation 0.017) compared with pressure-wired measurement. No significant difference was observed between them (P = 0.09). Though the narrowing degree of in the involved ICA was about 70%, the simulated and measured CAFA (0.942/0.937) revealed a functionally nonsignificant stenosis which was also verified by a compensatory final CBF (fronto-temporal/fronto-parietal region: 51.58/45.62 ml/100 g/min) and slightly prolonged ATT (1.23/1.4 s) in the involved territories, together with a normal left-right percentage difference (2.1-8.85%). The DSA based CFD simulation showed good consistence with invasive approach and could be used as a cost-saving and efficient way to study the relationship between hemodynamic disorder caused by ICA stenosis and subsequent perfusion variations in brain. Further research should focus on the role of noninvasive pressure-based CAFA in screening asymptomatic ischemia-causing carotid stenosis.

  10. TU-H-CAMPUS-IeP3-02: Neurovascular 4D Parametric Imaging Using Co-Registration of Biplane DSA Sequences with 3D Vascular Geometry Obtained From Cone Beam CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balasubramoniam, A; Bednarek, D; Rudin, S

    Purpose: To create 4D parametric images using biplane Digital Subtraction Angiography (DSA) sequences co-registered with the 3D vascular geometry obtained from Cone Beam-CT (CBCT). Methods: We investigated a method to derive multiple 4D Parametric Imaging (PI) maps using only one CBCT acquisition. During this procedure a 3D-DSA geometry is stored and used subsequently for all 4D images. Each time a biplane DSA is acquired, we calculate 2D parametric maps of Bolus Arrival Time (BAT), Mean Transit Time (MTT) and Time to Peak (TTP). Arterial segments which are nearly parallel with one of the biplane imaging planes in the 2D parametricmore » maps are co-registered with the 3D geometry. The values in the remaining vascular network are found using spline interpolation since the points chosen for co-registration on the vasculature are discrete and remaining regions need to be interpolated. To evaluate the method we used a patient CT volume data set for 3D printing a neurovascular phantom containing a complete Circle of Willis. We connected the phantom to a flow loop with a peristaltic pump, simulating physiological flow conditions. Contrast media was injected with an automatic injector at 10 ml/sec. Images were acquired with a Toshiba Infinix C-arm and 4D parametric image maps of the vasculature were calculated. Results: 4D BAT, MTT, and TTP parametric image maps of the Circle of Willis were derived. We generated color-coded 3D geometries which avoided artifacts due to vessel overlap or foreshortening in the projection direction. Conclusion: The software was tested successfully and multiple 4D parametric images were obtained from biplane DSA sequences without the need to acquire additional 3D-DSA runs. This can benefit the patient by reducing the contrast media and the radiation dose normally associated with these procedures. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.« less

  11. Overview and development of EDA tools for integration of DSA into patterning solutions

    NASA Astrophysics Data System (ADS)

    Torres, J. Andres; Fenger, Germain; Khaira, Daman; Ma, Yuansheng; Granik, Yuri; Kapral, Chris; Mitra, Joydeep; Krasnova, Polina; Ait-Ferhat, Dehia

    2017-03-01

    Directed Self-Assembly is the method by which a self-assembly polymer is forced to follow a desired geometry defined or influenced by a guiding pattern. Such guiding pattern uses surface potentials, confinement or both to achieve polymer configurations that result in circuit-relevant topologies, which can be patterned onto a substrate. Chemo, and grapho epitaxy of lines and space structures are now routinely inspected at full wafer level to understand the defectivity limits of the materials and their maximum resolution. In the same manner, there is a deeper understanding about the formation of cylinders using grapho-epitaxy processes. Academia has also contributed by developing methods that help reduce the number of masks in advanced nodes by "combining" DSA-compatible groups, thus reducing the total cost of the process. From the point of view of EDA, new tools are required when a technology is adopted, and most technologies are adopted when they show a clear cost-benefit over alternative techniques. In addition, years of EDA development have led to the creation of very flexible toolkits that permit rapid prototyping and evaluation of new process alternatives. With the development of high-chi materials, and by moving away of the well characterized PS-PMMA systems, as well as novel integrations in the substrates that work in tandem with diblock copolymer systems, it is necessary to assess any new requirements that may or may not need custom tools to support such processes. Hybrid DSA processes (which contain both chemo and grapho elements), are currently being investigated as possible contenders for sub-5nm process techniques. Because such processes permit the re-distribution of discontinuities in the regular arrays between the substrate and a cut operation, they have the potential to extend the number of applications for DSA. This paper illustrates the reason as to why some DSA processes can be supported by existing rules and technology, while other processes require the development of highly customized correction tools and models. It also illustrates how developing DSA cannot be done in isolation, and it requires the full collaboration of EDA, Material's suppliers, Manufacturing equipment, Metrology, and electronic manufacturers.

  12. Directed self-assembly of poly(styrene)-block-poly(acrylic acid) copolymers for sub-20nm pitch patterning

    NASA Astrophysics Data System (ADS)

    Cheng, Jing; Lawson, Richard A.; Yeh, Wei-Ming; Jarnagin, Nathan D.; Peters, Andrew; Tolbert, Laren M.; Henderson, Clifford L.

    2012-03-01

    Directed self-assembly (DSA) of block copolymers is a promising technology for extending the patterning capability of current lithographic exposure tools. For example, production of sub-40 nm pitch features using 193nm exposure technologies is conceivably possible using DSA methods without relying on time consuming, challenging, and expensive multiple patterning schemes. Significant recent work has focused on demonstration of the ability to produce large areas of regular grating structures with low numbers of defects using self-assembly of poly(styrene)-b-poly(methyl methacrylate) copolymers (PS-b-PMMA). While these recent results are promising and have shown the ability to print pitches approaching 20 nm using DSA, the ability to advance to even smaller pitches will be dependent upon the ability to develop new block copolymers with higher χ values and the associated alignment and block removal processes required to achieve successful DSA with these new materials. This paper reports on work focused on identifying higher χ block copolymers and their associated DSA processes for sub-20 nm pitch patterning. In this work, DSA using polystyrene-b-polyacid materials has been explored. Specifically, it is shown that poly(styrene)-b-poly(acrylic acid) copolymers (PS-b-PAA) is one promising material for achieving substantially smaller pitch patterns than those possible with PS-b-PMMA while still utilizing simple hydrocarbon polymers. In fact, it is anticipated that much of the learning that has been done with the PS-b-PMMA system, such as development of highly selective plasma etch block removal procedures, can be directly leveraged or transferred to the PS-b-PAA system. Acetone vapor annealing of PS-b-PAA (Mw=16,000 g/mol with 50:50 mole ratio of PS:PAA) and its self-assembly into a lamellar morphology is demonstrated to generate a pattern pitch size (L0) of 21 nm. The χ value for PS-b-PAA was estimated from fingerprint pattern pitch data to be approximately 0.18 which is roughly 4.5 times greater than the χ for PS-b-PMMA (χPS-b-PMMA ~ 0.04).

  13. Objective criteria for acceptability and constancy tests of digital subtraction angiography.

    PubMed

    de las Heras, Hugo; Torres, Ricardo; Fernández-Soto, José Miguel; Vañó, Eliseo

    2016-01-01

    Demonstrate an objective procedure to quantify image quality in digital subtraction angiography (DSA) and suggest thresholds for acceptability and constancy tests. Series of images were obtained in a DSA system simulating a small (paediatric) and a large patient using the dynamic phantom described in the IEC and DIN standards for acceptance tests of DSA equipment. Image quality was quantified using measurements of contrast-to-noise ratio (CNR). Overall scores combining the CNR of 10-100 mg/ml Iodine at a vascular diameter of 1-4 mm in a homogeneous background were defined. Phantom entrance surface air kerma (Ka,e) was measured with an ionisation chamber. The visibility of a low-contrast vessel in DSA images has been identified with a CNR value of 0.50 ± 0.03. Despite using 14 times more Ka,e (8.85 vs 0.63 mGy/image), the protocol for large patients showed a decrease in the overall score CNRsum of 67% (4.21 ± 0.06 vs 2.10 ± 0.05). The uncertainty in the results of the objective method was below 5%. Objective evaluation of DSA images using CNR is feasible with dedicated phantom measurements. An objective methodology has been suggested for acceptance tests compliant with the IEC/DIN standards. The defined overall scores can serve to fix a reproducible baseline for constancy tests, as well as to study the device stability within one acquisition series and compare different imaging protocols. This work provides aspects that have not been included in the recent European guidelines on Criteria for Acceptability of Medical Radiological Equipment. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. Detection and characterization of unruptured intracranial aneurysms: Comparison of 3T MRA and DSA.

    PubMed

    Mine, Benjamin; Pezzullo, Martina; Roque, Gonçalo; David, Philippe; Metens, Thierry; Lubicz, Boris

    2015-06-01

    To compare magnetic resonance angiography (MRA) at 3 Tesla (3T) and digital subtraction angiography (DSA) for the detection and characterization of unruptured intracranial aneurysms (UIA). This study has been approved by our local ethical committee. From February to August 2010, 40 consecutive patients with UIA contemporarily underwent MRA at 3T including time-of-flight (TOF-MRA) and contrast enhanced (CE-MRA) techniques and DSA. MR images were independently reviewed by 3 radiologists and DSA images were reviewed by 2 radiologists together. Interobserver and intertechnique agreements were assessed for aneurysm detection and characterization including maximal diameter, neck width and the presence of a bleb or a branch arising from the sac. DS angiography revealed 56 aneurysms. Mean sensitivity and positive predictive value of MRA were 91.4% and 93.4% respectively. For UIA < 3 mm and those ≥ 3 mm, MRA had a mean sensitivity of 74.1% and 100% respectively. Intertechnique and interobserver agreements were substantial for the measurement of UIA maximal diameter (mean κ, 0.607 and 0.601 respectively) and were moderate and fair for neck width measurement respectively (mean κ, 0.456 and 0.285 respectively). For bleb detection, intertechnique and interobserver agreements were fair and slight respectively (mean κ, 0.312 and 0.116 respectively) whereas both were slight for detection of branches arising from the sac (mean κ, 0.151 and 0.070 respectively). MR angiography at 3T has a high sensitivity for the detection of UIA. However, it remains significantly inferior to DSA for morphological characterization of UIA. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  15. Nonenhanced peripheral MR-angiography (MRA) at 3 Tesla: evaluation of quiescent-interval single-shot MRA in patients undergoing digital subtraction angiography.

    PubMed

    Wagner, Moritz; Knobloch, Gesine; Gielen, Martin; Lauff, Marie-Teres; Romano, Valentina; Hamm, Bernd; Kröncke, Thomas

    2015-04-01

    Quiescent-interval single-shot MRA (QISS-MRA) is a promising nonenhanced imaging technique for assessment of peripheral arterial disease (PAD). Previous studies at 3 Tesla included only very limited numbers of patients for correlation of QISS-MRA with digital subtraction angiography (DSA) as standard of reference (SOR). The aim of this prospective institutional review board-approved study was to compare QISS-MRA at 3 Tesla with DSA in a larger patient group. Our study included 32 consecutive patients who underwent QISS-MRA, contrast-enhanced MRA (CE-MRA), and DSA. Two readers independently performed a per-segment evaluation of QISS-MRA and CE-MRA for image quality and identification of non-significant stenosis (<50%) versus significant stenosis (50-100%). The final dataset included 1,027 vessel segments. Reader 1 and 2 rated image quality as diagnostic in 96.8 and 98.0% of the vessel segments on QISS-MRA and in 99.3 and 98.4% of the vessel segments on CE-MRA, respectively. DSA was available for 922 segments and detected significant stenosis in 133 segments (14.4%). Consensus reading yielded the following diagnostic parameters for QISS-MRA versus CE-MRA: sensitivity: 83.5% (111/133) versus 82.7% (110/133), p = 0.80; specificity: 93.9% (741/789) versus 95.7% (755/789), p = 0.25; and diagnostic accuracy: 92.4% (852/922) versus 93.8% (865/922), p = 0.35. In conclusion, using DSA as SOR, QISS-MRA and CE-MRA at 3 Tesla showed similar diagnostic accuracy in the assessment of PAD. A limitation of QISS-MRA was the lower rate of assessable vessel segments compared to CE-MRA.

  16. Validation of a dye stain assay for vaginally inserted HEC-filled microbicide applicators

    PubMed Central

    Katzen, Lauren L.; Fernández-Romero, José A.; Sarna, Avina; Murugavel, Kailapuri G.; Gawarecki, Daniel; Zydowsky, Thomas M.; Mensch, Barbara S.

    2011-01-01

    Background The reliability and validity of self-reports of vaginal microbicide use are questionable given the explicit understanding that participants are expected to comply with study protocols. Our objective was to optimize the Population Council's previously validated dye stain assay (DSA) and related procedures, and establish predictive values for the DSA's ability to identify vaginally inserted single-use, low-density polyethylene microbicide applicators filled with hydroxyethylcellulose gel. Methods Applicators, inserted by 252 female sex workers enrolled in a microbicide feasibility study in Southern India, served as positive controls for optimization and validation experiments. Prior to validation, optimal dye concentration and staining time were ascertained. Three validation experiments were conducted to determine sensitivity, specificity, negative predictive values and positive predictive values. Results The dye concentration of 0.05% (w/v) FD&C Blue No. 1 Granular Food Dye and staining time of five seconds were determined to be optimal and were used for the three validation experiments. There were a total of 1,848 possible applicator readings across validation experiments; 1,703 (92.2%) applicator readings were correct. On average, the DSA performed with 90.6% sensitivity, 93.9% specificity, and had a negative predictive value of 93.8% and a positive predictive value of 91.0%. No statistically significant differences between experiments were noted. Conclusions The DSA was optimized and successfully validated for use with single-use, low-density polyethylene applicators filled with hydroxyethylcellulose (HEC) gel. We recommend including the DSA in future microbicide trials involving vaginal gels in order to identify participants who have low adherence to dosing regimens. In doing so, we can develop strategies to improve adherence as well as investigate the association between product use and efficacy. PMID:21992983

  17. Minimally Invasive Monitoring of Chronic Central Venous Catheter Patency in Mice Using Digital Subtraction Angiography (DSA)

    PubMed Central

    Figueiredo, Giovanna; Fiebig, Teresa; Kirschner, Stefanie; Nikoubashman, Omid; Kabelitz, Lisa; Othman, Ahmed; Nonn, Andrea; Kramer, Martin; Brockmann, Marc A.

    2015-01-01

    Background Repetitive administration of medication or contrast agents is frequently performed in mice. The introduction of vascular access mini-ports (VAMP) for mice allows long-term vascular catheterization, hereby eliminating the need for repeated vessel puncture. With catheter occlusion being the most commonly reported complication of chronic jugular vein catheterization, we tested whether digital subtraction angiography (DSA) can be utilized to evaluate VAMP patency in mice. Methods Twenty-three mice underwent catheterization of the jugular vein and subcutaneous implantation of a VAMP. The VAMP was flushed every second day with 50 μL of heparinized saline solution (25 IU/ml). DSA was performed during injection of 100 μL of an iodine based contrast agent using an industrial X-ray inspection system intraoperatively, as well as 7±2 and 14±2 days post implantation. Results DSA allowed localization of catheter tip position, to rule out dislocation, kinking or occlusion of a microcatheter, and to evaluate parent vessel patency. In addition, we observed different ante- and retrograde collateral flow patterns in case of jugular vein occlusion. More exactly, 30% of animals showed parent vessel occlusion after 7±2 days in our setting. At this time point, nevertheless, all VAMPs verified intravascular contrast administration. After 14±2 days, intravascular contrast injection was verified in 70% of the implanted VAMPs, whereas at this point of time 5 animals had died or were sacrificed and in 2 mice parent vessel occlusion hampered intravascular contrast injection. Notably, no occlusion of the catheter itself was observed. Conclusion From our observations we conclude DSA to be a fast and valuable minimally invasive tool for investigation of catheter and parent vessel patency and for anatomical studies of collateral blood flow in animals as small as mice. PMID:26098622

  18. Correlation between carotid bifurcation calcium burden on non-enhanced CT and percentage stenosis, as confirmed by digital subtraction angiography

    PubMed Central

    Sarikaya, B; Lohman, B; Mckinney, A M; Gadani, S; Irfan, M; Lucato, L

    2012-01-01

    Objectives Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods 50 patients (aged 41–82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered “significant”. Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm3 were utilised and Pearson'S correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate–strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm3 was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a “score” that could predict high grade stenosis. PMID:21896662

  19. Re-exposure to beta cell autoantigens in pancreatic allograft recipients with preexisting beta cell autoantibodies.

    PubMed

    Mujtaba, Muhammad Ahmad; Fridell, Jonathan; Book, Benita; Faiz, Sara; Sharfuddin, Asif; Wiebke, Eric; Rigby, Mark; Taber, Tim

    2015-11-01

    Re-exposure to beta cell autoantigens and its relevance in the presence of donor-specific antibodies (DSA) in pancreatic allograft recipients is not well known. Thirty-three patients requiring a pancreas transplant were enrolled in an IRB approved study. They underwent prospective monitoring for DSA and beta cell autoantibody (BCAA) levels to GAD65, insulinoma-associated antigen 2 (IA-2), insulin (micro-IAA [mIAA]), and islet-specific zinc transporter isoform-8 (ZnT8). Twenty-five (75.7%) had pre-transplant BCAA. Twenty had a single antibody (mIAA n = 15, GAD65 n = 5); five had two or more BCAA (GAD65 + mIAA n = 2, GAD65 + mIAA+IA-2 n = 2, GA65 + mIAA+IA-2 + ZnT8 = 1). No changes in GAD65 (p > 0.29), IA-2 (>0.16), and ZnT8 (p > 0.07) were observed between pre-transplant and post-transplant at 6 or 12 months. A decrease in mIAA from pre- to post-6 months (p < 0.0001), 12 months (p < 0.0001), and from post-6 to post-12 months (p = 0.0002) was seen. No new BCAA was observed at one yr. Seven (21.0%) developed de novo DSA. The incidence of DSA was 24% in patients with BCAA vs. 25% in patients without BCAA (p = 0.69). Pancreatic allograft function of patients with vs. without BCAA, and with and without BCAA + DSA was comparable until last follow-up (three yr). Re-exposure to beta cell autoantigens by pancreas transplant may not lead to increased levels or development of new BCAA or pancreatic allograft dysfunction. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Arterial spin labeling MR imaging aids to identify cortical venous drainage of dural arteriovenous fistulas.

    PubMed

    Kang, Ji Hee; Yun, Tae Jin; Rhim, Jong Kook; Cho, Young Dae; Yoo, Dong Hyun; Yoo, Roh-Eul; Kang, Koung Mi; Choi, Seung Hong; Kim, Ji-Hoon; Sohn, Chul-Ho; Han, Moon Hee

    2018-05-01

    Cortical venous drainage (CVD) increases the probability of intracranial hemorrhage and mortality rate of dural arteriovenous fistulas (DAVF). Although digital subtraction angiography (DSA) is the most accurate method to determine CVD in DAVFs, this modality has limitations due to its invasive nature and radiation issues. The purpose of this study was to evaluate the diagnostic utility of arterial spin-labeling perfusion-weighted images (ASL-PWI) to identify CVD in patients with DAVF.The Institutional Review Board of our hospital approved this retrospective study. ASL-PWI features of 22 patients with DAVF were retrospectively reviewed for the presence of bright signal intensity in cortical veins and brain parenchyma. DAVF with bright signal intensity in cortical veins and/or brain parenchyma was regarded as having CVD. Using DSA as a reference standard, sensitivity, specificity, positive predictive value, and negative predictive value of ASL-PWI for detecting CVD were calculated.Based on DSA features, 11 (11/22, 50%) patients were classified as having "aggressive" pattern with CVD. Eleven (11/22, 50%) patients also showed bright signal intensity in cortical veins (9/22, 41%) and/or brain parenchyma (4/22, 18%) on ASL-PWI. The 11 patients who had "Aggressive" pattern on DSA were the same 11 patients who were classified as having "aggressive" pattern on ASL-PWI. ASL-PWI showed perfect diagnostic performance for identifying CVD with sensitivity, specificity, positive predictive value, and negative predictive value of 100% for all.Thus, ASL-PWI could be used as a noninvasive mean to predict the presence of CVD in patients with DAVFs. It has the potential as a screening tool to evaluate DAVF prior to invasive DSA.

  1. Angular Multigrid Preconditioner for Krylov-Based Solution Techniques Applied to the Sn Equations with Highly Forward-Peaked Scattering

    NASA Astrophysics Data System (ADS)

    Turcksin, Bruno; Ragusa, Jean C.; Morel, Jim E.

    2012-01-01

    It is well known that the diffusion synthetic acceleration (DSA) methods for the Sn equations become ineffective in the Fokker-Planck forward-peaked scattering limit. In response to this deficiency, Morel and Manteuffel (1991) developed an angular multigrid method for the 1-D Sn equations. This method is very effective, costing roughly twice as much as DSA per source iteration, and yielding a maximum spectral radius of approximately 0.6 in the Fokker-Planck limit. Pautz, Adams, and Morel (PAM) (1999) later generalized the angular multigrid to 2-D, but it was found that the method was unstable with sufficiently forward-peaked mappings between the angular grids. The method was stabilized via a filtering technique based on diffusion operators, but this filtering also degraded the effectiveness of the overall scheme. The spectral radius was not bounded away from unity in the Fokker-Planck limit, although the method remained more effective than DSA. The purpose of this article is to recast the multidimensional PAM angular multigrid method without the filtering as an Sn preconditioner and use it in conjunction with the Generalized Minimal RESidual (GMRES) Krylov method. The approach ensures stability and our computational results demonstrate that it is also significantly more efficient than an analogous DSA-preconditioned Krylov method.

  2. Exploration of suitable dry etch technologies for directed self-assembly

    NASA Astrophysics Data System (ADS)

    Yamashita, Fumiko; Nishimura, Eiichi; Yatsuda, Koichi; Mochiki, Hiromasa; Bannister, Julie

    2012-03-01

    Directed self-assembly (DSA) has shown the potential to replace traditional resist patterns and provide a lower cost alternative for sub-20-nm patterns. One of the possible roadblocks for DSA implementation is the ability to etch the polymers to produce quality masks for subsequent etch processes. We have studied the effects of RF frequency and etch chemistry for dry developing DSA patterns. The results of the study showed a capacitively-coupled plasma (CCP) reactor with very high frequency (VHF) had superior pattern development after the block co-polymer (BCP) etch. The VHF CCP demonstrated minimal BCP height loss and line edge roughness (LER)/line width roughness (LWR). The advantage of CCP over ICP is the low dissociation so the etch rate of BCP is maintained low enough for process control. Additionally, the advantage of VHF is the low electron energy with a tight ion energy distribution that enables removal of the polymethyl methacrylate (PMMA) with good selectivity to polystyrene (PS) and minimal LER/LWR. Etch chemistries were evaluated on the VHF CCP to determine ability to treat the BCPs to increase etch resistance and feature resolution. The right combination of RF source frequencies and etch chemistry can help overcome the challenges of using DSA patterns to create good etch results.

  3. Novel Virtual Screening Approach for the Discovery of Human Tyrosinase Inhibitors

    PubMed Central

    Ai, Ni; Welsh, William J.; Santhanam, Uma; Hu, Hong; Lyga, John

    2014-01-01

    Tyrosinase is the key enzyme involved in the human pigmentation process, as well as the undesired browning of fruits and vegetables. Compounds inhibiting tyrosinase catalytic activity are an important class of cosmetic and dermatological agents which show high potential as depigmentation agents used for skin lightening. The multi-step protocol employed for the identification of novel tyrosinase inhibitors incorporated the Shape Signatures computational algorithm for rapid screening of chemical libraries. This algorithm converts the size and shape of a molecule, as well its surface charge distribution and other bio-relevant properties, into compact histograms (signatures) that lend themselves to rapid comparison between molecules. Shape Signatures excels at scaffold hopping across different chemical families, which enables identification of new actives whose molecular structure is distinct from other known actives. Using this approach, we identified a novel class of depigmentation agents that demonstrated promise for skin lightening product development. PMID:25426625

  4. Novel virtual screening approach for the discovery of human tyrosinase inhibitors.

    PubMed

    Ai, Ni; Welsh, William J; Santhanam, Uma; Hu, Hong; Lyga, John

    2014-01-01

    Tyrosinase is the key enzyme involved in the human pigmentation process, as well as the undesired browning of fruits and vegetables. Compounds inhibiting tyrosinase catalytic activity are an important class of cosmetic and dermatological agents which show high potential as depigmentation agents used for skin lightening. The multi-step protocol employed for the identification of novel tyrosinase inhibitors incorporated the Shape Signatures computational algorithm for rapid screening of chemical libraries. This algorithm converts the size and shape of a molecule, as well its surface charge distribution and other bio-relevant properties, into compact histograms (signatures) that lend themselves to rapid comparison between molecules. Shape Signatures excels at scaffold hopping across different chemical families, which enables identification of new actives whose molecular structure is distinct from other known actives. Using this approach, we identified a novel class of depigmentation agents that demonstrated promise for skin lightening product development.

  5. Micro-Doppler analysis of multiple frequency continuous wave radar signatures

    NASA Astrophysics Data System (ADS)

    Anderson, Michael G.; Rogers, Robert L.

    2007-04-01

    Micro-Doppler refers to Doppler scattering returns produced by non rigid-body motion. Micro-Doppler gives rise to many detailed radar image features in addition to those associated with bulk target motion. Targets of different classes (for example, humans, animals, and vehicles) produce micro-Doppler images that are often distinguishable even by nonexpert observers. Micro-Doppler features have great potential for use in automatic target classification algorithms. Although the potential benefit of using micro-Doppler in classification algorithms is high, relatively little experimental (non-synthetic) micro-Doppler data exists. Much of the existing experimental data comes from highly cooperative targets (human or vehicle targets directly approaching the radar). This research involved field data collection and analysis of micro-Doppler radar signatures from non-cooperative targets. The data was collected using a low cost Xband multiple frequency continuous wave (MFCW) radar with three transmit frequencies. The collected MFCW radar signatures contain data from humans, vehicles, and animals. The presented data includes micro-Doppler signatures previously unavailable in the literature such as crawling humans and various animal species. The animal micro-Doppler signatures include deer, dog, and goat datasets. This research focuses on the analysis of micro-Doppler from noncooperative targets approaching the radar at various angles, maneuvers, and postures.

  6. Ballistic missile precession frequency extraction based on the Viterbi & Kalman algorithm

    NASA Astrophysics Data System (ADS)

    Wu, Longlong; Xie, Yongjie; Xu, Daping; Ren, Li

    2015-12-01

    Radar Micro-Doppler signatures are of great potential for target detection, classification and recognition. In the mid-course phase, warheads flying outside the atmosphere are usually accompanied by precession. Precession may induce additional frequency modulations on the returned radar signal, which can be regarded as a unique signature and provide additional information that is complementary to existing target recognition methods. The main purpose of this paper is to establish a more actual precession model of conical ballistic missile warhead and extract the precession parameters by utilizing Viterbi & Kalman algorithm, which improving the precession frequency estimation accuracy evidently , especially in low SNR.

  7. Fast Physically Accurate Rendering of Multimodal Signatures of Distributed Fracture in Heterogeneous Materials.

    PubMed

    Visell, Yon

    2015-04-01

    This paper proposes a fast, physically accurate method for synthesizing multimodal, acoustic and haptic, signatures of distributed fracture in quasi-brittle heterogeneous materials, such as wood, granular media, or other fiber composites. Fracture processes in these materials are challenging to simulate with existing methods, due to the prevalence of large numbers of disordered, quasi-random spatial degrees of freedom, representing the complex physical state of a sample over the geometric volume of interest. Here, I develop an algorithm for simulating such processes, building on a class of statistical lattice models of fracture that have been widely investigated in the physics literature. This algorithm is enabled through a recently published mathematical construction based on the inverse transform method of random number sampling. It yields a purely time domain stochastic jump process representing stress fluctuations in the medium. The latter can be readily extended by a mean field approximation that captures the averaged constitutive (stress-strain) behavior of the material. Numerical simulations and interactive examples demonstrate the ability of these algorithms to generate physically plausible acoustic and haptic signatures of fracture in complex, natural materials interactively at audio sampling rates.

  8. An evaluation of the signature extension approach to large area crop inventories utilizing space image data. [Kansas and North Dakota

    NASA Technical Reports Server (NTRS)

    Nalepka, R. F. (Principal Investigator); Cicone, R. C.; Stinson, J. L.; Balon, R. J.

    1977-01-01

    The author has identified the following significant results. Two examples of haze correction algorithms were tested: CROP-A and XSTAR. The CROP-A was tested in a unitemporal mode on data collected in 1973-74 over ten sample segments in Kansas. Because of the uniformly low level of haze present in these segments, no conclusion could be reached about CROP-A's ability to compensate for haze. It was noted, however, that in some cases CROP-A made serious errors which actually degraded classification performance. The haze correction algorithm XSTAR was tested in a multitemporal mode on 1975-76 LACIE sample segment data over 23 blind sites in Kansas and 18 sample segments in North Dakota, providing wide range of haze levels and other conditions for algorithm evaluation. It was found that this algorithm substantially improved signature extension classification accuracy when a sum-of-likelihoods classifier was used with an alien rejection threshold.

  9. A Novel Preclinical Model of Moderate Primary Blast-Induced Traumatic Brain Injury.

    PubMed

    Divani, Afshin A; Murphy, Amanda J; Meints, Joyce; Sadeghi-Bazargani, Homayoun; Nordberg, Jessica; Monga, Manoj; Low, Walter C; Bhatia, Prerana M; Beilman, Greg J; SantaCruz, Karen S

    2015-07-15

    Blast-induced traumatic brain injury (bTBI) is the "signature" injury of the recent Iraq and Afghanistan wars. Here, we present a novel method to induce bTBI using shock wave (SW) lithotripsy. Using a lithotripsy machine, Wistar rats (N = 70; 408.3 ± 93 g) received five SW pulses to the right side of the frontal cortex at 24 kV and a frequency of 60 Hz. Animals were then randomly divided into three study endpoints: 24 h (n = 25), 72 h (n = 19) and 168 h (n = 26). Neurological and behavioral assessments (Garcia's test, beam walking, Rotarod, and elevated plus maze) were performed at the baseline, and further assessments followed at 3, 6, 24, 72, and 168 h post-injury, if applicable. We performed digital subtraction angiography (DSA) to assess presence of cerebral vasospasm due to induced bTBI. Damage to brain tissue was assessed by an overall histological severity (OHS) score based on depth of injury, area of hemorrhage, and extent of axonal injury. Except for beam walking, OHS was significantly correlated with the other three outcome measures with at least one of their assessments during the first 6 h after the experiment. OHS manifested the highest absolute correlation coefficients with anxiety at the baseline and 6 h post-injury (r(baseline) = -0.75, r(6hrs) = 0.85; p<0.05). Median hemispheric differences for contrast peak values (obtained from DSA studies) for 24, 72, and 168 h endpoints were 3.45%, 3.05% and 0.2%, respectively, with statistically significant differences at 1 versus 7 d (p<0.05) and 3 versus 7 d (p<0.01). In this study, we successfully established a preclinical rat model of bTBI with characteristics similar to those observed in clinical cases. This new method may be useful for future investigations aimed at understanding bTBI pathophysiology.

  10. Estimation and Coordination of Sequence Patterns for Frequency Hopping Dynamic Spectrum Access Networks

    DTIC Science & Technology

    2014-03-27

    Technology (AFIT). Research at AFIT investigates the use of DSA for both civilian and military applications while advancing technology in the area of radio...other military platforms is vital for successful operations. Twelve core functions comprise the US Air Force: Nuclear Deterrence Operations, Special...problems. This Air Force report discusses “Frequency Agile Spectrum Utilization”, a sub-topic of DSA, as a potential capability area [3]. Military

  11. Verification of directed self-assembly (DSA) guide patterns through machine learning

    NASA Astrophysics Data System (ADS)

    Shim, Seongbo; Cai, Sibo; Yang, Jaewon; Yang, Seunghune; Choi, Byungil; Shin, Youngsoo

    2015-03-01

    Verification of full-chip DSA guide patterns (GPs) through simulations is not practical due to long runtime. We develop a decision function (or functions), which receives n geometry parameters of a GP as inputs and predicts whether the GP faithfully produces desired contacts (good) or not (bad). We take a few sample GPs to construct the function; DSA simulations are performed for each GP to decide whether it is good or bad, and the decision is marked in n-dimensional space. The hyper-plane that separates good marks and bad marks in that space is determined through machine learning process, and corresponds to our decision function. We try a single global function that can be applied to any GP types, and a series of functions in which each function is customized for different GP type; they are then compared and assessed in 10nm technology.

  12. Interstellar Pickup Ion Acceleration in the Turbulent Magnetic Field at the Solar Wind Termination Shock Using a Focused Transport Approach

    NASA Astrophysics Data System (ADS)

    Ye, Junye; le Roux, Jakobus A.; Arthur, Aaron D.

    2016-08-01

    We study the physics of locally born interstellar pickup proton acceleration at the nearly perpendicular solar wind termination shock (SWTS) in the presence of a random magnetic field spiral angle using a focused transport model. Guided by Voyager 2 observations, the spiral angle is modeled with a q-Gaussian distribution. The spiral angle fluctuations, which are used to generate the perpendicular diffusion of pickup protons across the SWTS, play a key role in enabling efficient injection and rapid diffusive shock acceleration (DSA) when these particles follow field lines. Our simulations suggest that variation of both the shape (q-value) and the standard deviation (σ-value) of the q-Gaussian distribution significantly affect the injection speed, pitch-angle anisotropy, radial distribution, and the efficiency of the DSA of pickup protons at the SWTS. For example, increasing q and especially reducing σ enhances the DSA rate.

  13. Advanced fast 3D DSA model development and calibration for design technology co-optimization

    NASA Astrophysics Data System (ADS)

    Lai, Kafai; Meliorisz, Balint; Muelders, Thomas; Welling, Ulrich; Stock, Hans-Jürgen; Marokkey, Sajan; Demmerle, Wolfgang; Liu, Chi-Chun; Chi, Cheng; Guo, Jing

    2017-04-01

    Direct Optimization (DO) of a 3D DSA model is a more optimal approach to a DTCO study in terms of accuracy and speed compared to a Cahn Hilliard Equation solver. DO's shorter run time (10X to 100X faster) and linear scaling makes it scalable to the area required for a DTCO study. However, the lack of temporal data output, as opposed to prior art, requires a new calibration method. The new method involves a specific set of calibration patterns. The calibration pattern's design is extremely important when temporal data is absent to obtain robust model parameters. A model calibrated to a Hybrid DSA system with a set of device-relevant constructs indicates the effectiveness of using nontemporal data. Preliminary model prediction using programmed defects on chemo-epitaxy shows encouraging results and agree qualitatively well with theoretical predictions from a strong segregation theory.

  14. Selective directed self-assembly of coexisting morphologies using block copolymer blends

    NASA Astrophysics Data System (ADS)

    Stein, A.; Wright, G.; Yager, K. G.; Doerk, G. S.; Black, C. T.

    2016-08-01

    Directed self-assembly (DSA) of block copolymers is an emergent technique for nano-lithography, but is limited in the range of structures possible in a single fabrication step. Here we expand on traditional DSA chemical patterning. A blend of lamellar- and cylinder-forming block copolymers assembles on specially designed surface chemical line gratings, leading to the simultaneous formation of coexisting ordered morphologies in separate areas of the substrate. The competing energetics of polymer chain distortions and chemical mismatch with the substrate grating bias the system towards either line/space or dot array patterns, depending on the pitch and linewidth of the prepattern. This is in contrast to the typical DSA, wherein assembly of a single-component block copolymer on chemical templates generates patterns of either lines/spaces (lamellar) or hexagonal dot arrays (cylinders). In our approach, the chemical template encodes desired local spatial arrangements of coexisting design motifs, self-assembled from a single, sophisticated resist.

  15. Magnetic Resonance Imaging (MRI) and Digital Subtraction Angiography Investigation of Childhood Moyamoya Disease.

    PubMed

    Song, Peiji; Qin, Jing; Lun, Han; Qiao, Penggang; Xie, Anming; Li, Gongjie

    2017-11-01

    Because digital subtraction angiography (DSA) is not an ideal angiographic examination for moyamoya disease in the pediatric population, magnetic resonance angiography (MRA) provides a noninvasive contrast-free angiographic examination; whereas magnetic resonance imaging (MRI) provides superior spatial resolution and soft-tissue contrast for lesion assessment. Ninety patients with moyamoya disease were examined by MRI and DSA to assess the distribution of lesions and their diagnostic agreement between modalities. MRI examination revealed 439 lesions. Punctate lesions were the most abundant, followed by patchy lesions. These lesions generally covered a smaller area than the abnormal-vascular corresponding brain parenchyma. Steno-occlusive changes at bilateral anterior, medial, and posterior cerebral arteries were identified by MRA and DSA. MRI showed moderate agreement in identifying lesions after steno-occlusive changes in anterior and medial cerebral arteries, and good agreement in posterior cerebral arteries; 6% to 11% of cases were misdiagnosed by MRA.

  16. Serrated Flow and Dynamic Strain Aging in Fe-Mn-C TWIP Steel

    NASA Astrophysics Data System (ADS)

    Lan, Peng; Zhang, Jiaquan

    2018-01-01

    The tensile behavior, serrated flow, and dynamic strain aging of Fe-(20 to 24)Mn-(0.4 to 0.6)C twinning-induced plasticity (TWIP) steel have been investigated. A mathematical approach to analyze the DSA and PLC band parameters has been developed. For Fe-(20 to 24)Mn-(0.4 to 0.6)C TWIP steel with a theoretical ordering index (TOI) between 0.1 and 0.3, DSA can occur at the very beginning of plastic deformation and provide serrations during work hardening, while for TOI less than 0.1 the occurrence of DSA is delayed and twinning-dominant work hardening remains relatively smooth. The critical strain for the onset of DSA and PLC bands in Fe-Mn-C TWIP steels decreases as C content increases, while the numbers of serrations and bands increase. As Mn content increases, the critical strain for DSA and PLC band varies irregularly, but the numbers of serrations and bands increase. For Fe-(20 to 24)Mn-(0.4 to 0.6)C TWIP steel with grain size of about 10 to 20 μm, the twinning-induced work hardening rate is about 2.5 to 3.0 GPa, while the DSA-dominant hardening rate is about 2.0 GPa on average. With increasing engineering strain from 0.01 to 0.55 at an applied strain rate of 0.001s-1, the cycle time for PLC bands in Fe-Mn-C TWIP steel increases from 6.5 to 162 seconds, while the band velocity decreases from 4.5 to 0.5 mm s-1, and the band strain increases from 0.005 to 0.08. Increasing applied strain rate leads to a linear increase of band velocity despite composition differences. In addition, the influence of the Mn and C content on the tensile properties of Fe-Mn-C TWIP steel has been also studied. As C content increases, the yield strength and tensile strength of Fe-Mn-C TWIP steel increase, but the total elongation variation against C content is dependent on Mn content. As Mn content increases, the yield strength and tensile strength decrease, while the total elongation increases, despite C content. Taking both tensile properties and serrated flow behavior into consideration, Fe-22Mn-0.4C TWIP steel shows excellent mechanical performance with a high product of tensile strength and total elongation and a slightly serrated stress-strain response. To suppress the negative effect of DSA in Fe-Mn-C TWIP steels on the stability of tensile behavior, a TOI lower than 0.1 is strongly suggested.

  17. Relative threshold of detection of active arterial bleeding: in vitro comparison of MDCT and digital subtraction angiography.

    PubMed

    Roy-Choudhury, Shuvro H; Gallacher, David J; Pilmer, John; Rankin, Sheila; Fowler, Geoff; Steers, Jeff; Dourado, Renato; Woodburn, Paul; Adam, Andreas

    2007-11-01

    The objective of our study was to determine the relative sensitivity and the lowest threshold of bleeding detectable with digital subtraction angiography (DSA) and with MDCT using an in vitro physiologic system. A closed pulsatile cardiopulmonary bypass circuit was connected to tubes traversing a water bath to simulate the abdominal aorta and inferior vena cava. Three smaller interconnecting acrylic plastic tubes were connected as branches to the aortic tubing to simulate branch vessels. One of the three tubes, the control, had no holes in it, one had a 100-microm hole, and one had a 280-microm hole. The leakage rates were predetermined with a cardiac output of 2 and 4 L/min and with a mean arterial pressure (MAP) ranging from 30 to 100 mm Hg for each hole size. The following studies were performed for each of the predetermined leakage rates. For study 1, 16-MDCT was performed using bolus tracking after 35 mL of contrast medium had been injected into a simulated peripheral vein. For study 2, DSA was performed using a 4-French straight catheter placed 10 cm proximal to the holes (selective first aortic branch cannulation). For study 3, DSA was performed with a catheter placed in the small branch at the site of the hole (highly superselective). For study 4, 16-MDCT was performed with a catheter placed as in study 2, 10 cm proximal to the holes, for the detection of lower leakage rates. Cine loops of MDCT and DSA images were examined by two blinded observers to detect extravasation from the holes in the tubes (i.e., the branch arteries). Interobserver agreement was studied using Cohen's kappa statistic. The threshold to detect bleeding was as follows for each study: For IV contrast-enhanced MDCT (study 1), it was 0.35 mL/min; DSA with a catheter 10 cm proximal to the holes (study 2), 0.96 mL/min; DSA with a catheter at the holes (study 3), 0.05 mL/min [corrected] or lower; and intraarterial selective MDCT (study 4), 0.05 mL/min [corrected] or lower. The ease of detection improved with increasing MAPs and larger volumes of leakage. Interobserver correlation was excellent. In vitro, i.v. contrast-enhanced MDCT is more sensitive than first-order aortic branch-selective DSA in detecting active hemorrhage unless the catheter position is highly superselective and is close to the bleeding artery. These results suggest that MDCT can be used as the initial imaging technique in the diagnosis of active hemorrhage if the clinical condition of the patient allows.

  18. Quantitative coronary angiography using image recovery techniques for background estimation in unsubtracted images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wong, Jerry T.; Kamyar, Farzad; Molloi, Sabee

    2007-10-15

    Densitometry measurements have been performed previously using subtracted images. However, digital subtraction angiography (DSA) in coronary angiography is highly susceptible to misregistration artifacts due to the temporal separation of background and target images. Misregistration artifacts due to respiration and patient motion occur frequently, and organ motion is unavoidable. Quantitative densitometric techniques would be more clinically feasible if they could be implemented using unsubtracted images. The goal of this study is to evaluate image recovery techniques for densitometry measurements using unsubtracted images. A humanoid phantom and eight swine (25-35 kg) were used to evaluate the accuracy and precision of the followingmore » image recovery techniques: Local averaging (LA), morphological filtering (MF), linear interpolation (LI), and curvature-driven diffusion image inpainting (CDD). Images of iodinated vessel phantoms placed over the heart of the humanoid phantom or swine were acquired. In addition, coronary angiograms were obtained after power injections of a nonionic iodinated contrast solution in an in vivo swine study. Background signals were estimated and removed with LA, MF, LI, and CDD. Iodine masses in the vessel phantoms were quantified and compared to known amounts. Moreover, the total iodine in left anterior descending arteries was measured and compared with DSA measurements. In the humanoid phantom study, the average root mean square errors associated with quantifying iodine mass using LA and MF were approximately 6% and 9%, respectively. The corresponding average root mean square errors associated with quantifying iodine mass using LI and CDD were both approximately 3%. In the in vivo swine study, the root mean square errors associated with quantifying iodine in the vessel phantoms with LA and MF were approximately 5% and 12%, respectively. The corresponding average root mean square errors using LI and CDD were both 3%. The standard deviations in the differences between measured iodine mass in left anterior descending arteries using DSA and LA, MF, LI, or CDD were calculated. The standard deviations in the DSA-LA and DSA-MF differences (both {approx}21 mg) were approximately a factor of 3 greater than that of the DSA-LI and DSA-CDD differences (both {approx}7 mg). Local averaging and morphological filtering were considered inadequate for use in quantitative densitometry. Linear interpolation and curvature-driven diffusion image inpainting were found to be effective techniques for use with densitometry in quantifying iodine mass in vitro and in vivo. They can be used with unsubtracted images to estimate background anatomical signals and obtain accurate densitometry results. The high level of accuracy and precision in quantification associated with using LI and CDD suggests the potential of these techniques in applications where background mask images are difficult to obtain, such as lumen volume and blood flow quantification using coronary arteriography.« less

  19. Science of Land Target Spectral Signatures

    DTIC Science & Technology

    2013-04-03

    F. Meriaudeau, T. Downey , A. Wig , A. Passian, M. Buncick, T.L. Ferrell, Fiber optic sensor based on gold island plasmon resonance , Sensors and...processing, detection algorithms, sensor fusion, spectral signature modeling Dr. J. Michael Cathcart Georgia Tech Research Corporation Office of...target detection and sensor fusion. The phenomenology research continued to focus on spectroscopic soil measurements, optical property analyses, field

  20. Water quality parameter measurement using spectral signatures

    NASA Technical Reports Server (NTRS)

    White, P. E.

    1973-01-01

    Regression analysis is applied to the problem of measuring water quality parameters from remote sensing spectral signature data. The equations necessary to perform regression analysis are presented and methods of testing the strength and reliability of a regression are described. An efficient algorithm for selecting an optimal subset of the independent variables available for a regression is also presented.

  1. Modelling the passive microwave signature from land surfaces: a review of recent results and application to the SMOS & SMAP soil moisture retrieval algorithms

    USDA-ARS?s Scientific Manuscript database

    Two passive microwave missions are currently operating at L-band to monitor surface soil moisture (SM) over continental surfaces. The SMOS sensor, based on an innovative interferometric technology enabling multi-angular signatures of surfaces to be measured, was launched in November 2009....

  2. Multi-frequency and polarimetric radar backscatter signatures for discrimination between agricultural crops at the Flevoland experimental test site

    NASA Technical Reports Server (NTRS)

    Freeman, A.; Villasenor, J.; Klein, J. D.

    1991-01-01

    We describe the calibration and analysis of multi-frequency, multi-polarization radar backscatter signatures over an agriculture test site in the Netherlands. The calibration procedure involved two stages: in the first stage, polarimetric and radiometric calibrations (ignoring noise) were carried out using square-base trihedral corner reflector signatures and some properties of the clutter background. In the second stage, a novel algorithm was used to estimate the noise level in the polarimetric data channels by using the measured signature of an idealized rough surface with Bragg scattering (the ocean in this case). This estimated noise level was then used to correct the measured backscatter signatures from the agriculture fields. We examine the significance of several key parameters extracted from the calibrated and noise-corrected backscatter signatures. The significance is assessed in terms of the ability to uniquely separate among classes from 13 different backscatter types selected from the test site data, including eleven different crops, one forest and one ocean area. Using the parameters with the highest separation for a given class, we use a hierarchical algorithm to classify the entire image. We find that many classes, including ocean, forest, potato, and beet, can be identified with high reliability, while the classes for which no single parameter exhibits sufficient separation have higher rates of misclassification. We expect that modified decision criteria involving simultaneous consideration of several parameters increase performance for these classes.

  3. Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing.

    PubMed

    Ionita, Ciprian N; Mokin, Maxim; Varble, Nicole; Bednarek, Daniel R; Xiang, Jianping; Snyder, Kenneth V; Siddiqui, Adnan H; Levy, Elad I; Meng, Hui; Rudin, Stephen

    2014-03-13

    Additive manufacturing (3D printing) technology offers a great opportunity towards development of patient-specific vascular anatomic models, for medical device testing and physiological condition evaluation. However, the development process is not yet well established and there are various limitations depending on the printing materials, the technology and the printer resolution. Patient-specific neuro-vascular anatomy was acquired from computed tomography angiography and rotational digital subtraction angiography (DSA). The volumes were imported into a Vitrea 3D workstation (Vital Images Inc.) and the vascular lumen of various vessels and pathologies were segmented using a "marching cubes" algorithm. The results were exported as Stereo Lithographic (STL) files and were further processed by smoothing, trimming, and wall extrusion (to add a custom wall to the model). The models were printed using a Polyjet printer, Eden 260V (Objet-Stratasys). To verify the phantom geometry accuracy, the phantom was reimaged using rotational DSA, and the new data was compared with the initial patient data. The most challenging part of the phantom manufacturing was removal of support material. This aspect could be a serious hurdle in building very tortuous phantoms or small vessels. The accuracy of the printed models was very good: distance analysis showed average differences of 120 μm between the patient and the phantom reconstructed volume dimensions. Most errors were due to residual support material left in the lumen of the phantom. Despite the post-printing challenges experienced during the support cleaning, this technology could be a tremendous benefit to medical research such as in device development and testing.

  4. Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing

    NASA Astrophysics Data System (ADS)

    Ionita, Ciprian N.; Mokin, Maxim; Varble, Nicole; Bednarek, Daniel R.; Xiang, Jianping; Snyder, Kenneth V.; Siddiqui, Adnan H.; Levy, Elad I.; Meng, Hui; Rudin, Stephen

    2014-03-01

    Additive manufacturing (3D printing) technology offers a great opportunity towards development of patient-specific vascular anatomic models, for medical device testing and physiological condition evaluation. However, the development process is not yet well established and there are various limitations depending on the printing materials, the technology and the printer resolution. Patient-specific neuro-vascular anatomy was acquired from computed tomography angiography and rotational digital subtraction angiography (DSA). The volumes were imported into a Vitrea 3D workstation (Vital Images Inc.) and the vascular lumen of various vessels and pathologies were segmented using a "marching cubes" algorithm. The results were exported as Stereo Lithographic (STL) files and were further processed by smoothing, trimming, and wall extrusion (to add a custom wall to the model). The models were printed using a Polyjet printer, Eden 260V (Objet-Stratasys). To verify the phantom geometry accuracy, the phantom was reimaged using rotational DSA, and the new data was compared with the initial patient data. The most challenging part of the phantom manufacturing was removal of support material. This aspect could be a serious hurdle in building very tortuous phantoms or small vessels. The accuracy of the printed models was very good: distance analysis showed average differences of 120 μm between the patient and the phantom reconstructed volume dimensions. Most errors were due to residual support material left in the lumen of the phantom. Despite the post-printing challenges experienced during the support cleaning, this technology could be a tremendous benefit to medical research such as in device development and testing.

  5. Automated analysis in generic groups

    NASA Astrophysics Data System (ADS)

    Fagerholm, Edvard

    This thesis studies automated methods for analyzing hardness assumptions in generic group models, following ideas of symbolic cryptography. We define a broad class of generic and symbolic group models for different settings---symmetric or asymmetric (leveled) k-linear groups --- and prove ''computational soundness'' theorems for the symbolic models. Based on this result, we formulate a master theorem that relates the hardness of an assumption to solving problems in polynomial algebra. We systematically analyze these problems identifying different classes of assumptions and obtain decidability and undecidability results. Then, we develop automated procedures for verifying the conditions of our master theorems, and thus the validity of hardness assumptions in generic group models. The concrete outcome is an automated tool, the Generic Group Analyzer, which takes as input the statement of an assumption, and outputs either a proof of its generic hardness or shows an algebraic attack against the assumption. Structure-preserving signatures are signature schemes defined over bilinear groups in which messages, public keys and signatures are group elements, and the verification algorithm consists of evaluating ''pairing-product equations''. Recent work on structure-preserving signatures studies optimality of these schemes in terms of the number of group elements needed in the verification key and the signature, and the number of pairing-product equations in the verification algorithm. While the size of keys and signatures is crucial for many applications, another aspect of performance is the time it takes to verify a signature. The most expensive operation during verification is the computation of pairings. However, the concrete number of pairings is not captured by the number of pairing-product equations considered in earlier work. We consider the question of what is the minimal number of pairing computations needed to verify structure-preserving signatures. We build an automated tool to search for structure-preserving signatures matching a template. Through exhaustive search we conjecture lower bounds for the number of pairings required in the Type~II setting and prove our conjecture to be true. Finally, our tool exhibits examples of structure-preserving signatures matching the lower bounds, which proves tightness of our bounds, as well as improves on previously known structure-preserving signature schemes.

  6. Unusual Congenital Aortic Anomaly with Rare Common Celiamesenteric Trunk Variation: MR Angiography and Digital Substraction Angiography Findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tosun, Ozgur; Sanlidilek, Umman; Cetin, Huseyin

    2007-09-15

    Magnetic resonance angiography and digital substraction angiography (DSA) findings in a case with a rare congenital thoracoabdominal aortic hypoplasia and common celiamesenteric trunk variation with occlusion of infrarenal abdominal aorta are described here. To our knowledge, this aortic anomaly has not been previously described in the English literature. DSA is the optimum imaging modality for determination of aortic hypoplasia, associated vascular malformations, collateral vessels, and direction of flow within vessels.

  7. Disparate rates of acute rejection and donor-specific antibodies among high-immunologic risk renal transplant subgroups receiving antithymocyte globulin induction.

    PubMed

    Patel, Samir J; Suki, Wadi N; Loucks-DeVos, Jennifer; Graviss, Edward A; Nguyen, Duc T; Knight, Richard J; Kuten, Samantha A; Moore, Linda W; Teeter, Larry D; Gaber, Lillian W; Gaber, A Osama

    2016-08-01

    Lymphocyte-depleting induction lowers acute rejection (AR) rates among high-immunologic risk (HIR) renal transplant recipients, including African Americans (AAs), retransplants, and the sensitized. It is unclear whether different HIR subgroups experience similarly low rates of AR. We aimed to describe the incidence of AR and de novo donor-specific antibody (dnDSA) among HIR recipients categorized by age, race, or donor type. All received antithymocyte globulin (ATG) induction and triple maintenance immunosuppression. A total of 464 HIR recipients from 2007 to 2014 were reviewed. AR and dnDSA rates at 1 year for the entire population were 14% and 27%, respectively. AR ranged from 6.7% among living donor (LD) recipients to 30% in younger AA deceased donor (DD) recipients. De novo donor-specific antibody at 1 year ranged from 7% in older non-AA LD recipients to 32% in AAs. AA race remained as an independent risk factor for AR among DD recipients and for dnDSA among all HIR recipients. Development of both AR and dnDSA within the first year was associated with a 54% graft survival at 5 years and was an independent risk factor for graft loss. Despite utilization of recommended immunosuppression for HIR recipients, substantial disparities exist among subgroups, warranting further consideration of individualized immunosuppression in certain HIR subgroups. © 2016 Steunstichting ESOT.

  8. Estimating effective dose to pediatric patients undergoing interventional radiology procedures using anthropomorphic phantoms and MOSFET dosimeters.

    PubMed

    Miksys, Nelson; Gordon, Christopher L; Thomas, Karen; Connolly, Bairbre L

    2010-05-01

    The purpose of this study was to estimate the effective doses received by pediatric patients during interventional radiology procedures and to present those doses in "look-up tables" standardized according to minute of fluoroscopy and frame of digital subtraction angiography (DSA). Organ doses were measured with metal oxide semiconductor field effect transistor (MOSFET) dosimeters inserted within three anthropomorphic phantoms, representing children at ages 1, 5, and 10 years, at locations corresponding to radiosensitive organs. The phantoms were exposed to mock interventional radiology procedures of the head, chest, and abdomen using posteroanterior and lateral geometries, varying magnification, and fluoroscopy or DSA exposures. Effective doses were calculated from organ doses recorded by the MOSFET dosimeters and are presented in look-up tables according to the different age groups. The largest effective dose burden for fluoroscopy was recorded for posteroanterior and lateral abdominal procedures (0.2-1.1 mSv/min of fluoroscopy), whereas procedures of the head resulted in the lowest effective doses (0.02-0.08 mSv/min of fluoroscopy). DSA exposures of the abdomen imparted higher doses (0.02-0.07 mSv/DSA frame) than did those involving the head and chest. Patient doses during interventional procedures vary significantly depending on the type of procedure. User-friendly look-up tables may provide a helpful tool for health care providers in estimating effective doses for an individual procedure.

  9. Characterization of d-succinylase from Cupriavidus sp. P4-10-C and its application in d-amino acid synthesis.

    PubMed

    Sumida, Yosuke; Iwai, Sachio; Nishiya, Yoshiaki; Kumagai, Shinya; Yamada, Toshihide; Azuma, Masayuki

    2018-03-01

    d-Amino acids are important building blocks for various compounds, such as pharmaceuticals and agrochemicals. A more cost-effective enzymatic method for d-amino acid production is needed in the industry. We improved a one-pot enzymatic method for d-amino acid production by the dynamic kinetic resolution of N-succinyl amino acids using two enzymes: d-succinylase (DSA) from Cupriavidus sp. P4-10-C, which hydrolyzes N-succinyl-d-amino acids enantioselectively to their corresponding d-amino acid, and N-succinyl amino acid racemase (NSAR, EC.4.2.1.113) from Geobacillus stearothermophilus NCA1503. In this study, DSA and NSAR were purified and their properties were investigated. The optimum temperature of DSA was 50°C and it was stable up to 55°C. The optimum pH of DSA and NSAR was around 7.5. In d-phenylalanine production, the optical purity of product was improved to 91.6% ee from the examination about enzyme concentration. Moreover, 100 mM N-succinyl-dl-tryptophan was converted to d-tryptophan at 81.8% yield with 94.7% ee. This enzymatic method could be useful for the industrial production of various d-amino acids. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  10. Can specific transcriptional regulators assemble a universal cancer signature?

    NASA Astrophysics Data System (ADS)

    Roy, Janine; Isik, Zerrin; Pilarsky, Christian; Schroeder, Michael

    2013-10-01

    Recently, there is a lot of interest in using biomarker signatures derived from gene expression data to predict cancer progression. We assembled signatures of 25 published datasets covering 13 types of cancers. How do these signatures compare with each other? On one hand signatures answering the same biological question should overlap, whereas signatures predicting different cancer types should differ. On the other hand, there could also be a Universal Cancer Signature that is predictive independently of the cancer type. Initially, we generate signatures for all datasets using classical approaches such as t-test and fold change and then, we explore signatures resulting from a network-based method, that applies the random surfer model of Google's PageRank algorithm. We show that the signatures as published by the authors and the signatures generated with classical methods do not overlap - not even for the same cancer type - whereas the network-based signatures strongly overlap. Selecting 10 out of 37 universal cancer genes gives the optimal prediction for all cancers thus taking a first step towards a Universal Cancer Signature. We furthermore analyze and discuss the involved genes in terms of the Hallmarks of cancer and in particular single out SP1, JUN/FOS and NFKB1 and examine their specific role in cancer progression.

  11. A Study of Bi-Directional Reflectance Distribution Functions and Their Effect on Infrared Signature Models

    DTIC Science & Technology

    2007-03-01

    66 3.5.1 Specular Reflection Assumption . . . . . . . . . . . . . . . . . . . 70 3.5.2 Radiosity ...69 3.31. Radiosity Algorithm Flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 3.32. POV...3.5.2 Radiosity . The first algorithm implemented to attempt to hemispher- ically integrate the irradiance contribution was classical radiosity as

  12. Terrain type recognition using ERTS-1 MSS images

    NASA Technical Reports Server (NTRS)

    Gramenopoulos, N.

    1973-01-01

    For the automatic recognition of earth resources from ERTS-1 digital tapes, both multispectral and spatial pattern recognition techniques are important. Recognition of terrain types is based on spatial signatures that become evident by processing small portions of an image through selected algorithms. An investigation of spatial signatures that are applicable to ERTS-1 MSS images is described. Artifacts in the spatial signatures seem to be related to the multispectral scanner. A method for suppressing such artifacts is presented. Finally, results of terrain type recognition for one ERTS-1 image are presented.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hymel, Ross

    The Public Key (PK) FPGA software performs asymmetric authentication using the 163-bit Elliptic Curve Digital Signature Algorithm (ECDSA) on an embedded FPGA platform. A digital signature is created on user-supplied data, and communication with a host system is performed via a Serial Peripheral Interface (SPI) bus. Software includes all components necessary for signing, including custom random number generator for key creation and SHA-256 for data hashing.

  14. Simulation of atmospheric and terrestrial background signatures for detection and tracking scenarios

    NASA Astrophysics Data System (ADS)

    Schweitzer, Caroline; Stein, Karin

    2015-10-01

    In the fields of early warning, one is depending on reliable image exploitation: Only if the applied detection and tracking algorithms work efficiently, the threat approach alert can be given fast enough to ensure an automatic initiation of the countermeasure. In order to evaluate the performance of those algorithms for a certain electro-optical (EO) sensor system, test sequences need to be created as realistic and comprehensive as possible. Since both, background and target signature, depend on the environmental conditions, a detailed knowledge of the meteorology and climatology is necessary. Trials for measuring these environmental characteristics serve as a solid basis, but might only constitute the conditions during a rather short period of time. To represent the entire variation of meteorology and climatology that the future system will be exposed to, the application of comprehensive atmospheric modelling tools is essential. This paper gives an introduction of the atmospheric modelling tools that are currently used at Fraunhofer IOSB to simulate spectral background signatures in the infrared (IR) range. It is also demonstrated, how those signatures are affected by changing atmospheric and climatic conditions. In conclusion - and with a special focus on the modelling of different cloud types - sources of error and limits are discussed.

  15. Floating shock fitting via Lagrangian adaptive meshes

    NASA Technical Reports Server (NTRS)

    Vanrosendale, John

    1994-01-01

    In recent works we have formulated a new approach to compressible flow simulation, combining the advantages of shock-fitting and shock-capturing. Using a cell-centered Roe scheme discretization on unstructured meshes, we warp the mesh while marching to steady state, so that mesh edges align with shocks and other discontinuities. This new algorithm, the Shock-fitting Lagrangian Adaptive Method (SLAM) is, in effect, a reliable shock-capturing algorithm which yields shock-fitted accuracy at convergence. Shock-capturing algorithms like this, which warp the mesh to yield shock-fitted accuracy, are new and relatively untried. However, their potential is clear. In the context of sonic booms, accurate calculation of near-field sonic boom signatures is critical to the design of the High Speed Civil Transport (HSCT). SLAM should allow computation of accurate N-wave pressure signatures on comparatively coarse meshes, significantly enhancing our ability to design low-boom configurations for high-speed aircraft.

  16. Discovering causal signaling pathways through gene-expression patterns

    PubMed Central

    Parikh, Jignesh R.; Klinger, Bertram; Xia, Yu; Marto, Jarrod A.; Blüthgen, Nils

    2010-01-01

    High-throughput gene-expression studies result in lists of differentially expressed genes. Most current meta-analyses of these gene lists include searching for significant membership of the translated proteins in various signaling pathways. However, such membership enrichment algorithms do not provide insight into which pathways caused the genes to be differentially expressed in the first place. Here, we present an intuitive approach for discovering upstream signaling pathways responsible for regulating these differentially expressed genes. We identify consistently regulated signature genes specific for signal transduction pathways from a panel of single-pathway perturbation experiments. An algorithm that detects overrepresentation of these signature genes in a gene group of interest is used to infer the signaling pathway responsible for regulation. We expose our novel resource and algorithm through a web server called SPEED: Signaling Pathway Enrichment using Experimental Data sets. SPEED can be freely accessed at http://speed.sys-bio.net/. PMID:20494976

  17. Follow-up assessment of coiled intracranial aneurysms using zTE MRA as compared with TOF MRA: a preliminary image quality study.

    PubMed

    Shang, Song'an; Ye, Jing; Luo, Xianfu; Qu, Jianxun; Zhen, Yong; Wu, Jingtao

    2017-10-01

    To prospectively assess coiled intracranial aneurysms using a novel non-contrast enhanced zero echo time (zTE) MR angiography (MRA) method, and compare its image quality with time-of-flight (TOF) MRA, using digital subtraction angiography (DSA) as reference. Twenty-five patients (10 males and 15 females; age 53.96 ± 12.46 years) were enrolled in this monocentric study. MRA sequences were performed 24 h before DSA. Susceptibility artefact intensity and flow signal within the parent artery were carried out using a 4-point scale. Occlusion status was assessed using the 3-grade Montreal scale. Scores of zTE were higher than TOF for both susceptibility artefact intensity (3.42 ± 0.64, 2.92 ± 0.63, P = 0.01) and flow signal (3.66 ± 0.95, 3.24 ± 1.24, P = 0.01). DSA revealed 17 complete occlusions, five residual neck aneurysms and two residual aneurysms. Inter-observer agreement was excellent (weighted κ: 0.89) for zTE and good (weighted κ: 0.68) for TOF. Intermodality agreement was excellent for zTE (weighted κ: 0.95) and good for TOF (weighted κ: 0.80). Correlations of both MRA sequences with DSA were high (zTE, Spearman's ρ: 0.91; TOF, Spearman's ρ: 0.81). zTE MRA showed promising results for follow-up assessment of coiled intracranial aneurysms and was superior to TOF MRA for visualizing the parent artery and evaluating occlusion status. • Various MRA sequences were applied for follow-up assessment of coiled intracranial aneurysms. • zTE MRA was less sensitive to susceptibility artefacts and haemodynamics. • In this monocentric study, zTE MRA was equivalent to DSA. • zTE MRA maybe an alternative to TOF MRA for follow-up assessment.

  18. Cost-effectiveness of digital subtraction angiography in the setting of computed tomographic angiography negative subarachnoid hemorrhage.

    PubMed

    Jethwa, Pinakin R; Punia, Vineet; Patel, Tapan D; Duffis, E Jesus; Gandhi, Chirag D; Prestigiacomo, Charles J

    2013-04-01

    Recent studies have documented the high sensitivity of computed tomography angiography (CTA) in detecting a ruptured aneurysm in the presence of acute subarachnoid hemorrhage (SAH). The practice of digital subtraction angiography (DSA) when CTA does not reveal an aneurysm has thus been called into question. We examined this dilemma from a cost-effectiveness perspective by using current decision analysis techniques. A decision tree was created with the use of TreeAge Pro Suite 2012; in 1 arm, a CTA-negative SAH was followed up with DSA; in the other arm, patients were observed without further imaging. Based on literature review, costs and utilities were assigned to each potential outcome. Base-case and sensitivity analyses were performed to determine the cost-effectiveness of each strategy. A Monte Carlo simulation was then conducted by sampling each variable over a plausible distribution to evaluate the robustness of the model. With the use of a negative predictive value of 95.7% for CTA, observation was found to be the most cost-effective strategy ($6737/Quality Adjusted Life Year [QALY] vs $8460/QALY) in the base-case analysis. One-way sensitivity analysis demonstrated that DSA became the more cost-effective option if the negative predictive value of CTA fell below 93.72%. The Monte Carlo simulation produced an incremental cost-effectiveness ratio of $83 083/QALY. At the conventional willingness-to-pay threshold of $50 000/QALY, observation was the more cost-effective strategy in 83.6% of simulations. The decision to perform a DSA in CTA-negative SAH depends strongly on the sensitivity of CTA, and therefore must be evaluated at each center treating these types of patients. Given the high sensitivity of CTA reported in the current literature, performing DSA on all patients with CTA negative SAH may not be cost-effective at every institution.

  19. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: implications for planning 90Y radioembolization?

    PubMed

    Burgmans, M C; Too, C W; Kao, Y H; Goh, A S W; Chow, P K H; Tan, B S; Tay, K H; Lo, R H G

    2012-12-01

    To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. From August 2008 to November 2010, 79 patients (range 23-83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p<0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  20. Extraction of small boat harmonic signatures from passive sonar.

    PubMed

    Ogden, George L; Zurk, Lisa M; Jones, Mark E; Peterson, Mary E

    2011-06-01

    This paper investigates the extraction of acoustic signatures from small boats using a passive sonar system. Noise radiated from a small boats consists of broadband noise and harmonically related tones that correspond to engine and propeller specifications. A signal processing method to automatically extract the harmonic structure of noise radiated from small boats is developed. The Harmonic Extraction and Analysis Tool (HEAT) estimates the instantaneous fundamental frequency of the harmonic tones, refines the fundamental frequency estimate using a Kalman filter, and automatically extracts the amplitudes of the harmonic tonals to generate a harmonic signature for the boat. Results are presented that show the HEAT algorithms ability to extract these signatures. © 2011 Acoustical Society of America

  1. A Coincidence Signature Library for Multicoincidence Radionuclide Analysis Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Leon E.; Ellis, J E.; Valsan, Andrei B.

    Pacific Northwest National Laboratory (PNNL) is currently developing multicoincidence systems to perform trace radionuclide analysis at or near the sample collection point, for applications that include emergency response, nuclear forensics, and environmental monitoring. Quantifying radionuclide concentrations with these systems requires a library of accurate emission intensities for each detected signature, for all candidate radionuclides. To meet this need, a Coincidence Lookup Library (CLL) is being developed to calculate the emission intensities of coincident signatures from a user-specified radionuclide, or conversely, to determine the radionuclides that may be responsible for a specific detected coincident signature. The algorithms used to generate absolutemore » emission intensities and various query modes for our developmental CLL are described.« less

  2. Research on key technologies for data-interoperability-based metadata, data compression and encryption, and their application

    NASA Astrophysics Data System (ADS)

    Yu, Xu; Shao, Quanqin; Zhu, Yunhai; Deng, Yuejin; Yang, Haijun

    2006-10-01

    With the development of informationization and the separation between data management departments and application departments, spatial data sharing becomes one of the most important objectives for the spatial information infrastructure construction, and spatial metadata management system, data transmission security and data compression are the key technologies to realize spatial data sharing. This paper discusses the key technologies for metadata based on data interoperability, deeply researches the data compression algorithms such as adaptive Huffman algorithm, LZ77 and LZ78 algorithm, studies to apply digital signature technique to encrypt spatial data, which can not only identify the transmitter of spatial data, but also find timely whether the spatial data are sophisticated during the course of network transmission, and based on the analysis of symmetric encryption algorithms including 3DES,AES and asymmetric encryption algorithm - RAS, combining with HASH algorithm, presents a improved mix encryption method for spatial data. Digital signature technology and digital watermarking technology are also discussed. Then, a new solution of spatial data network distribution is put forward, which adopts three-layer architecture. Based on the framework, we give a spatial data network distribution system, which is efficient and safe, and also prove the feasibility and validity of the proposed solution.

  3. Missed Total Occlusion Due to the Occipital Artery Arising from the Internal Carotid Artery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ustunsoz, Bahri, E-mail: bustunsoz2000@yahoo.com; Gumus, Burcak; Koksal, Ali

    2007-02-15

    A 56-year-old man was referred for digital subtraction angiography (DSA) with an ultrasound diagnosis of right proximal internal carotid artery (ICA) stenosis for possible carotid artery stenting. DSA revealed total occlusion of the ICA and an occipital artery arising from the stump and simulating continuation of the ICA. An ascending pharyngeal artery also arose from the same occipital artery. This case is of interest because this is a rare variation besides being a cause of misdiagnosis at carotid ultrasound.

  4. Modeling and analysis of LWIR signature variability associated with 3D and BRDF effects

    NASA Astrophysics Data System (ADS)

    Adler-Golden, Steven; Less, David; Jin, Xuemin; Rynes, Peter

    2016-05-01

    Algorithms for retrieval of surface reflectance, emissivity or temperature from a spectral image almost always assume uniform illumination across the scene and horizontal surfaces with Lambertian reflectance. When these algorithms are used to process real 3-D scenes, the retrieved "apparent" values contain the strong, spatially dependent variations in illumination as well as surface bidirectional reflectance distribution function (BRDF) effects. This is especially problematic with horizontal or near-horizontal viewing, where many observed surfaces are vertical, and where horizontal surfaces can show strong specularity. The goals of this study are to characterize long-wavelength infrared (LWIR) signature variability in a HSI 3-D scene and develop practical methods for estimating the true surface values. We take advantage of synthetic near-horizontal imagery generated with the high-fidelity MultiService Electro-optic Signature (MuSES) model, and compare retrievals of temperature and directional-hemispherical reflectance using standard sky downwelling illumination and MuSES-based non-uniform environmental illumination.

  5. An adaptive tracker for ShipIR/NTCS

    NASA Astrophysics Data System (ADS)

    Ramaswamy, Srinivasan; Vaitekunas, David A.

    2015-05-01

    A key component in any image-based tracking system is the adaptive tracking algorithm used to segment the image into potential targets, rank-and-select the best candidate target, and the gating of the selected target to further improve tracker performance. This paper will describe a new adaptive tracker algorithm added to the naval threat countermeasure simulator (NTCS) of the NATO-standard ship signature model (ShipIR). The new adaptive tracking algorithm is an optional feature used with any of the existing internal NTCS or user-defined seeker algorithms (e.g., binary centroid, intensity centroid, and threshold intensity centroid). The algorithm segments the detected pixels into clusters, and the smallest set of clusters that meet the detection criterion is obtained by using a knapsack algorithm to identify the set of clusters that should not be used. The rectangular area containing the chosen clusters defines an inner boundary, from which a weighted centroid is calculated as the aim-point. A track-gate is then positioned around the clusters, taking into account the rate of change of the bounding area and compensating for any gimbal displacement. A sequence of scenarios is used to test the new tracking algorithm on a generic unclassified DDG ShipIR model, with and without flares, and demonstrate how some of the key seeker signals are impacted by both the ship and flare intrinsic signatures.

  6. Spectral mapping tools from the earth sciences applied to spectral microscopy data.

    PubMed

    Harris, A Thomas

    2006-08-01

    Spectral imaging, originating from the field of earth remote sensing, is a powerful tool that is being increasingly used in a wide variety of applications for material identification. Several workers have used techniques like linear spectral unmixing (LSU) to discriminate materials in images derived from spectral microscopy. However, many spectral analysis algorithms rely on assumptions that are often violated in microscopy applications. This study explores algorithms originally developed as improvements on early earth imaging techniques that can be easily translated for use with spectral microscopy. To best demonstrate the application of earth remote sensing spectral analysis tools to spectral microscopy data, earth imaging software was used to analyze data acquired with a Leica confocal microscope with mechanical spectral scanning. For this study, spectral training signatures (often referred to as endmembers) were selected with the ENVI (ITT Visual Information Solutions, Boulder, CO) "spectral hourglass" processing flow, a series of tools that use the spectrally over-determined nature of hyperspectral data to find the most spectrally pure (or spectrally unique) pixels within the data set. This set of endmember signatures was then used in the full range of mapping algorithms available in ENVI to determine locations, and in some cases subpixel abundances of endmembers. Mapping and abundance images showed a broad agreement between the spectral analysis algorithms, supported through visual assessment of output classification images and through statistical analysis of the distribution of pixels within each endmember class. The powerful spectral analysis algorithms available in COTS software, the result of decades of research in earth imaging, are easily translated to new sources of spectral data. Although the scale between earth imagery and spectral microscopy is radically different, the problem is the same: mapping material locations and abundances based on unique spectral signatures. (c) 2006 International Society for Analytical Cytology.

  7. Systematic computation with functional gene-sets among leukemic and hematopoietic stem cells reveals a favorable prognostic signature for acute myeloid leukemia.

    PubMed

    Yang, Xinan Holly; Li, Meiyi; Wang, Bin; Zhu, Wanqi; Desgardin, Aurelie; Onel, Kenan; de Jong, Jill; Chen, Jianjun; Chen, Luonan; Cunningham, John M

    2015-03-24

    Genes that regulate stem cell function are suspected to exert adverse effects on prognosis in malignancy. However, diverse cancer stem cell signatures are difficult for physicians to interpret and apply clinically. To connect the transcriptome and stem cell biology, with potential clinical applications, we propose a novel computational "gene-to-function, snapshot-to-dynamics, and biology-to-clinic" framework to uncover core functional gene-sets signatures. This framework incorporates three function-centric gene-set analysis strategies: a meta-analysis of both microarray and RNA-seq data, novel dynamic network mechanism (DNM) identification, and a personalized prognostic indicator analysis. This work uses complex disease acute myeloid leukemia (AML) as a research platform. We introduced an adjustable "soft threshold" to a functional gene-set algorithm and found that two different analysis methods identified distinct gene-set signatures from the same samples. We identified a 30-gene cluster that characterizes leukemic stem cell (LSC)-depleted cells and a 25-gene cluster that characterizes LSC-enriched cells in parallel; both mark favorable-prognosis in AML. Genes within each signature significantly share common biological processes and/or molecular functions (empirical p = 6e-5 and 0.03 respectively). The 25-gene signature reflects the abnormal development of stem cells in AML, such as AURKA over-expression. We subsequently determined that the clinical relevance of both signatures is independent of known clinical risk classifications in 214 patients with cytogenetically normal AML. We successfully validated the prognosis of both signatures in two independent cohorts of 91 and 242 patients respectively (log-rank p < 0.0015 and 0.05; empirical p < 0.015 and 0.08). The proposed algorithms and computational framework will harness systems biology research because they efficiently translate gene-sets (rather than single genes) into biological discoveries about AML and other complex diseases.

  8. Progress in interpreting CO2 lidar signatures to obtain cirrus microphysical and optical properties

    NASA Technical Reports Server (NTRS)

    Eberhard, Wynn L.

    1993-01-01

    One cloud/radiation issue at FIRE 2 that has been addressed by the CO2 lidar team is the zenith-enhanced backscatter (ZEB) signature from oriented crystals. A second topic is narrow-beam optical depth measurements using CO2 lidar. This paper describes the theoretical models we have developed for these phenomena and the data-processing algorithms derived from them.

  9. Using a genetic algorithm as an optimal band selector in the mid and thermal infrared (2.5-14 μm) to discriminate vegetation species.

    PubMed

    Ullah, Saleem; Groen, Thomas A; Schlerf, Martin; Skidmore, Andrew K; Nieuwenhuis, Willem; Vaiphasa, Chaichoke

    2012-01-01

    Genetic variation between various plant species determines differences in their physio-chemical makeup and ultimately in their hyperspectral emissivity signatures. The hyperspectral emissivity signatures, on the one hand, account for the subtle physio-chemical changes in the vegetation, but on the other hand, highlight the problem of high dimensionality. The aim of this paper is to investigate the performance of genetic algorithms coupled with the spectral angle mapper (SAM) to identify a meaningful subset of wavebands sensitive enough to discriminate thirteen broadleaved vegetation species from the laboratory measured hyperspectral emissivities. The performance was evaluated using an overall classification accuracy and Jeffries Matusita distance. For the multiple plant species, the targeted bands based on genetic algorithms resulted in a high overall classification accuracy (90%). Concentrating on the pairwise comparison results, the selected wavebands based on genetic algorithms resulted in higher Jeffries Matusita (J-M) distances than randomly selected wavebands did. This study concludes that targeted wavebands from leaf emissivity spectra are able to discriminate vegetation species.

  10. MRA versus DSA for follow-up of coiled intracranial aneurysms: a meta-analysis.

    PubMed

    van Amerongen, M J; Boogaarts, H D; de Vries, J; Verbeek, A L M; Meijer, F J A; Prokop, M; Bartels, R H M A

    2014-09-01

    MR angiography is proposed as a safer and less expensive alternative to the reference standard, DSA, in the follow-up of intracranial aneurysms treated with endovascular coil occlusion. We performed a systematic review and meta-analysis to evaluate the accuracy of TOF-MRA and contrast-enhanced MRA in detecting residual flow in the follow-up of coiled intracranial aneurysms. Literature was reviewed through the PubMed, Cochrane, and EMBASE data bases. In comparison with DSA, the sensitivity of TOF-MRA was 86% (95% CI: 82-89%), with a specificity of 84% (95% CI: 81-88%), for the detection of any recurrent flow. For contrast-enhanced MRA, the sensitivity and specificity were 86% (95% CI: 82-89%) and 89% (95% CI: 85-92%), respectively. Both TOF-MRA and contrast-enhanced MRA are shown to be highly accurate for detection of any recanalization in intracranial aneurysms treated with endovascular coil occlusion. © 2014 by American Journal of Neuroradiology.

  11. The Effects of a Dynamic Spectrum Access Overlay in LTE-Advanced Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Juan D. Deaton; Ryan E. Irwin; Luiz A. DaSilva

    As early as 2014, mobile network operators’ spectral capacity will be overwhelmed by the demand brought on by new devices and applications. To augment capacity and meet this demand, operators may choose to deploy a Dynamic Spectrum Access (DSA) overlay. The signaling and functionality required by such an overlay have not yet been fully considered in the architecture of the planned Long Term Evolution Advanced (LTE+) networks. This paper presents a Spectrum Accountability framework to be integrated into LTE+ architectures, defining specific element functionality, protocol interfaces, and signaling flow diagrams required to enforce the rights and responsibilities of primary andmore » secondary users. We also quantify, through integer programs, the benefits of using DSA channels to augment capacity under a scenario in which LTE+ network can opportunistically use TV and GSM spectrum. The framework proposed here may serve as a guide in the development of future LTE+ network standards that account for DSA.« less

  12. The Digital Slide Archive: A Software Platform for Management, Integration, and Analysis of Histology for Cancer Research.

    PubMed

    Gutman, David A; Khalilia, Mohammed; Lee, Sanghoon; Nalisnik, Michael; Mullen, Zach; Beezley, Jonathan; Chittajallu, Deepak R; Manthey, David; Cooper, Lee A D

    2017-11-01

    Tissue-based cancer studies can generate large amounts of histology data in the form of glass slides. These slides contain important diagnostic, prognostic, and biological information and can be digitized into expansive and high-resolution whole-slide images using slide-scanning devices. Effectively utilizing digital pathology data in cancer research requires the ability to manage, visualize, share, and perform quantitative analysis on these large amounts of image data, tasks that are often complex and difficult for investigators with the current state of commercial digital pathology software. In this article, we describe the Digital Slide Archive (DSA), an open-source web-based platform for digital pathology. DSA allows investigators to manage large collections of histologic images and integrate them with clinical and genomic metadata. The open-source model enables DSA to be extended to provide additional capabilities. Cancer Res; 77(21); e75-78. ©2017 AACR . ©2017 American Association for Cancer Research.

  13. Selective directed self-assembly of coexisting morphologies using block copolymer blends

    PubMed Central

    Stein, A.; Wright, G.; Yager, K. G.; Doerk, G. S.; Black, C. T.

    2016-01-01

    Directed self-assembly (DSA) of block copolymers is an emergent technique for nano-lithography, but is limited in the range of structures possible in a single fabrication step. Here we expand on traditional DSA chemical patterning. A blend of lamellar- and cylinder-forming block copolymers assembles on specially designed surface chemical line gratings, leading to the simultaneous formation of coexisting ordered morphologies in separate areas of the substrate. The competing energetics of polymer chain distortions and chemical mismatch with the substrate grating bias the system towards either line/space or dot array patterns, depending on the pitch and linewidth of the prepattern. This is in contrast to the typical DSA, wherein assembly of a single-component block copolymer on chemical templates generates patterns of either lines/spaces (lamellar) or hexagonal dot arrays (cylinders). In our approach, the chemical template encodes desired local spatial arrangements of coexisting design motifs, self-assembled from a single, sophisticated resist. PMID:27480327

  14. Selective directed self-assembly of coexisting morphologies using block copolymer blends

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stein, A.; Wright, G.; Yager, K. G.

    Directed self-assembly (DSA) of block copolymers is an emergent technique for nano-lithography, but is limited in the range of structures possible in a single fabrication step. We expand on traditional DSA chemical patterning. Moreover, a blend of lamellar- and cylinder-forming block copolymers assembles on specially designed surface chemical line gratings, leading to the simultaneous formation of coexisting ordered morphologies in separate areas of the substrate. The competing energetics of polymer chain distortions and chemical mismatch with the substrate grating bias the system towards either line/space or dot array patterns, depending on the pitch and linewidth of the prepattern. This contrastsmore » with typical DSA, wherein assembly of a single-component block copolymer on chemical templates generates patterns of either lines/spaces (lamellar) or hexagonal dot arrays (cylinders). In our approach, the chemical template encodes desired local spatial arrangements of coexisting design motifs, self-assembled from a single, sophisticated resist.« less

  15. Selective directed self-assembly of coexisting morphologies using block copolymer blends

    DOE PAGES

    Stein, A.; Wright, G.; Yager, K. G.; ...

    2016-08-02

    Directed self-assembly (DSA) of block copolymers is an emergent technique for nano-lithography, but is limited in the range of structures possible in a single fabrication step. We expand on traditional DSA chemical patterning. Moreover, a blend of lamellar- and cylinder-forming block copolymers assembles on specially designed surface chemical line gratings, leading to the simultaneous formation of coexisting ordered morphologies in separate areas of the substrate. The competing energetics of polymer chain distortions and chemical mismatch with the substrate grating bias the system towards either line/space or dot array patterns, depending on the pitch and linewidth of the prepattern. This contrastsmore » with typical DSA, wherein assembly of a single-component block copolymer on chemical templates generates patterns of either lines/spaces (lamellar) or hexagonal dot arrays (cylinders). In our approach, the chemical template encodes desired local spatial arrangements of coexisting design motifs, self-assembled from a single, sophisticated resist.« less

  16. Annual literature review of donor-specific HLA antibodies after organ transplantation.

    PubMed

    Kaneku, Hugo

    2011-01-01

    The literature review of post-transplant DSA published in 2011 shows: Observations after kidney and lung transplant in non-sensitized transplant recipients show that monitoring post-transplant HLA antibodies offers limited benefit in predicting acute rejection episodes. It remains to be seen if a different monitoring schedule and/ or studying other organs may show otherwise. Nevertheless, others have shown that monitoring post-transplant antibodies does identify patients at higher risk for chronic rejection. Studies in kidney, heart, and liver patients transplanted in the presence of preformed DSA show that detecting these antibodies early after transplant identifies a group of patients with greater risk for allograft dysfunction. New and larger studies using bortezomib and eculizumab to treat acute antibody-mediated rejection confirm earlier observations that these two therapies are effective in treating and preventing rejections. In general, identification of HLAantibodies and DSA after transplant is associated with higher rates of rejection and poor allograft survival in all organs examined. IgM antibodies appear to play an important role after lung transplants.

  17. Blind Quantum Signature with Blind Quantum Computation

    NASA Astrophysics Data System (ADS)

    Li, Wei; Shi, Ronghua; Guo, Ying

    2017-04-01

    Blind quantum computation allows a client without quantum abilities to interact with a quantum server to perform a unconditional secure computing protocol, while protecting client's privacy. Motivated by confidentiality of blind quantum computation, a blind quantum signature scheme is designed with laconic structure. Different from the traditional signature schemes, the signing and verifying operations are performed through measurement-based quantum computation. Inputs of blind quantum computation are securely controlled with multi-qubit entangled states. The unique signature of the transmitted message is generated by the signer without leaking information in imperfect channels. Whereas, the receiver can verify the validity of the signature using the quantum matching algorithm. The security is guaranteed by entanglement of quantum system for blind quantum computation. It provides a potential practical application for e-commerce in the cloud computing and first-generation quantum computation.

  18. Graphics Processing Unit (GPU) implementation of image processing algorithms to improve system performance of the Control, Acquisition, Processing, and Image Display System (CAPIDS) of the Micro-Angiographic Fluoroscope (MAF).

    PubMed

    Vasan, S N Swetadri; Ionita, Ciprian N; Titus, A H; Cartwright, A N; Bednarek, D R; Rudin, S

    2012-02-23

    We present the image processing upgrades implemented on a Graphics Processing Unit (GPU) in the Control, Acquisition, Processing, and Image Display System (CAPIDS) for the custom Micro-Angiographic Fluoroscope (MAF) detector. Most of the image processing currently implemented in the CAPIDS system is pixel independent; that is, the operation on each pixel is the same and the operation on one does not depend upon the result from the operation on the other, allowing the entire image to be processed in parallel. GPU hardware was developed for this kind of massive parallel processing implementation. Thus for an algorithm which has a high amount of parallelism, a GPU implementation is much faster than a CPU implementation. The image processing algorithm upgrades implemented on the CAPIDS system include flat field correction, temporal filtering, image subtraction, roadmap mask generation and display window and leveling. A comparison between the previous and the upgraded version of CAPIDS has been presented, to demonstrate how the improvement is achieved. By performing the image processing on a GPU, significant improvements (with respect to timing or frame rate) have been achieved, including stable operation of the system at 30 fps during a fluoroscopy run, a DSA run, a roadmap procedure and automatic image windowing and leveling during each frame.

  19. The role of cross-shock potential on pickup ion shock acceleration in the framework of focused transport theory

    DOE PAGES

    Zuo, Pingbing; Zhang, Ming; Rassoul, Hamid K.

    2013-10-03

    The focused transport theory is appropriate to describe the injection and acceleration of low-energy particles at shocks as an extension of diffusive shock acceleration (DSA). In this investigation, we aim to characterize the role of cross-shock potential (CSP) originated in the charge separation across the shock ramp on pickup ion (PUI) acceleration at various types of shocks with a focused transport model. The simulation results of energy spectrum and spatial density distribution for the cases with and without CSP added in the model are compared. With sufficient acceleration time, the focused transport acceleration finally falls into the DSA regime withmore » the power-law spectral index equal to the solution of the DSA theory. The CSP can affect the shape of the spectrum segment at lower energies, but it does not change the spectral index of the final power-law spectrum at high energies. It is found that the CSP controls the injection efficiency which is the fraction of PUIs reaching the DSA regime. A stronger CSP jump results in a dramatically improved injection efficiency. Our simulation results also show that the injection efficiency of PUIs is mass-dependent, which is lower for species with a higher mass. Additionally, the CSP is able to enhance the particle reflection upstream to produce a stronger intensity spike at the shock front. Lastly, we conclude that the CSP is a non-negligible factor that affects the dynamics of PUIs at shocks.« less

  20. Safety of Diagnostic Cerebral and Spinal Digital Subtraction Angiography in a Developing Country: A Single-Center Experience.

    PubMed

    Bashir, Qasim; Ishfaq, Asim; Baig, Ammad Anwar

    2018-02-01

    Digital subtraction angiography (DSA) remains the gold standard imaging modality for cerebrovascular disorders. In contrast to developed countries, the safety of the procedure is not extensively reported from the developing countries. Herein, we present a retrospective analysis of the basic technique, indications, and outcomes in 286 patients undergoing diagnostic cerebral and spinal angiography in a developing country, Pakistan. A retrospective review of patient demographics, procedural technique and complication rates of 286 consecutive patients undergoing the diagnostic cerebral/spinal angiography procedure at one institution from May 2013 to December 2015 was performed. Neurological, systemic, or local complications occurring within and after 24 h of the procedure were recorded. Mean age reported for all patients was 49.7 years. Of all the 286 cases, 175 were male (61.2%) and the rest female (111, 38.8%). Cerebral DSA was performed in 279 cases (97.6%), with 7 cases of spinal DSA (2.4%). Subarachnoid hemorrhage was the most common indication for DSA accounting for 88 cases (30.8%), closely followed by stroke (26.6%) and arteriosclerotic vascular disease (23.1%). No intra- or post-procedural neurological complications of any severity were seen in any of the 286 cases. One case of asymptomatic aortic dissection was reported (0.3%) in the entire cohort of patient population. Diagnostic cerebral/spinal digital subtraction angiography was found to be safe in Pakistan, with complication rates at par with and comparable to those reported in the developed world.

  1. Reliability of panoramic radiograph for carotid atheroma detection: a study in patients who fulfill the criteria for carotid endarterectomy.

    PubMed

    Damaskos, Spyros; Griniatsos, John; Tsekouras, Nikolaos; Georgopoulos, Sotirios; Klonaris, Chris; Bastounis, Elias; Tsiklakis, Kostas

    2008-11-01

    To evaluate the reliability of panoramic radiograph (PR) for carotid artery atheroma detection, by comparing its results with the carotid-vertebral digital subtraction angiography (DSA) findings, as well as with the detected calcium deposition in the carotid plaques, which were surgically resected, using direct radiographs. Forty consecutive patients suffering from carotid artery atherosclerotic occlusive disease confirmed by preoperative DSA, fulfilling the criteria for carotid endarterectomy, were operated on. Preoperatively, all of the patients had undergone PR, while postoperatively all of the surgically resected carotid plaques were radiographed using radiographic films and submitted to histologic examination. Compared with the DSA and the radiographic film findings, the PR results were classified as: 1) true-positive; 2) true-negative; 3) false-positive; or 4) false-negative. Panoramic radiograph has low sensitivity and specificity compared with the DSA findings and the direct radiographs results. However, a positive predictive value (PPV) of 100% per patient as well as for luminal stenosis >80% was documented. Even in the subgroup of patients who fulfill the criteria for carotid endarterectomy, PR has a low sensitivity and specificity; therefore, it cannot be considered to be a useful screening tool for atheroma detection in the general dental population. However, the 100% PPV per patient and for luminal stenosis >80%, indicates that positive calcification PR findings at the C(3)-C(4) region are highly suggestive for carotid artery atherosclerotic occlusive disease. Therefore, especially asymptomatic patients should be referred for further examination.

  2. Q-Learning and p-persistent CSMA based rendezvous protocol for cognitive radio networks operating with shared spectrum activity

    NASA Astrophysics Data System (ADS)

    Watson, Clifton L.; Biswas, Subir

    2014-06-01

    With an increasing demand for spectrum, dynamic spectrum access (DSA) has been proposed as viable means for providing the flexibility and greater access to spectrum necessary to meet this demand. Within the DSA concept, unlicensed secondary users temporarily "borrow" or access licensed spectrum, while respecting the licensed primary user's rights to that spectrum. As key enablers for DSA, cognitive radios (CRs) are based on software-defined radios which allow them to sense, learn, and adapt to the spectrum environment. These radios can operate independently and rapidly switch channels. Thus, the initial setup and maintenance of cognitive radio networks are dependent upon the ability of CR nodes to find each other, in a process known as rendezvous, and create a link on a common channel for the exchange of data and control information. In this paper, we propose a novel rendezvous protocol, known as QLP, which is based on Q-learning and the p-persistent CSMA protocol. With the QLP protocol, CR nodes learn which channels are best for rendezvous and thus adapt their behavior to visit those channels more frequently. We demonstrate through simulation that the QLP protocol provides a rendevous capability for DSA environments with different dynamics of PU activity, while attempting to achieve the following performance goals: (1) minimize the average time-to-rendezvous, (2) maximize system throughput, (3) minimize primary user interference, and (4) minimize collisions among CR nodes.

  3. Isolated v-lesion in kidney transplant recipients: Characteristics, association with DSA, and histological follow-up.

    PubMed

    Rabant, Marion; Boullenger, Fanny; Gnemmi, Viviane; Pellé, Gaëlle; Glowacki, François; Hertig, Alexandre; Brocheriou, Isabelle; Suberbielle, Caroline; Taupin, Jean-Luc; Anglicheau, Dany; Legendre, Christophe; Duong Van Huyen, Jean-Paul; Buob, David

    2018-04-01

    Isolated v-lesion (IvL) represents a rare and challenging situation in renal allograft biopsies because it is unknown whether IvL truly represents rejection, antibody- or T cell-mediated, or not. This multicentric retrospective study describes the clinicopathological features of IvL with an emphasis on the donor-specific antibody (DSA) status, histological follow-up, and graft survival. Inclusion criteria were the presence of v-lesion with minimal interstitial (i ≤ 1) and microvascular inflammation (g + ptc≤1). C4d-positive biopsies were excluded. We retrospectively found 33 IvL biopsies in 33 patients, mainly performed in the early posttransplantation period (median time 27 days) and clinically indicated in 66.7%. A minority of recipients (5/33, 15.2%) had DSA at the time of biopsy. IvL was treated by anti-rejection therapy in 21 cases (63.6%), whereas 12 (36.4%) were untreated. Seventy percent of untreated patients and 66% of treated patients showed favorable histological evolution on subsequent biopsy. Kidney graft survival in IvL was significantly higher than in a matched cohort of antibody-mediated rejection with arteritis. In conclusion, IvL is not primarily antibody-mediated and may show a favorable evolution. The heterogeneity of IvL pathophysiology on early biopsies should prompt DSA testing as well as close clinical and histological follow-up in all patients with IvL. © 2017 The American Society of Transplantation and the American Society of Transplant Surgeons.

  4. Magnetic Resonance Imaging Susceptibility-Weighted Imaging Lesion and Contrast Enhancement May Represent Infectious Intracranial Aneurysm in Infective Endocarditis.

    PubMed

    Cho, Sung-Min; Rice, Cory; Marquardt, Robert J; Zhang, Lucy Q; Khoury, Jean; Thatikunta, Prateek; Buletko, Andrew B; Hardman, Julian; Uchino, Ken; Wisco, Dolora

    2017-01-01

    Infectious intracranial aneurysm (IIA) can complicate infective endocarditis (IE). We aimed to describe the magnetic resonance imaging (MRI) characteristics of IIA. We reviewed IIAs among 116 consecutive patients with active IE by conducting a neurological evaluation at a single tertiary referral center from January 2015 to July 2016. MRIs and digital cerebral angiograms (DSA) were reviewed to identify MRI characteristics of IIAs. MRI susceptibility weighted imaging (SWI) was performed to collect data on cerebral microbleeds (CMBs) and sulcal SWI lesions. Out of 116 persons, 74 (63.8%) underwent DSA. IIAs were identified in 13 (17.6% of DSA, 11.2% of entire cohort) and 10 patients with aneurysms underwent MRI with SWI sequence. Nine (90%) out of 10 persons with IIAs had CMB >5 mm or sulcal lesions in SWI (9 in sulci, 6 in parenchyma, and 5 in both). Five out of 8 persons who underwent MRI brain with contrast had enhancement within the SWI lesions. In a multivariate logistic regression analysis, both sulcal SWI lesions (p < 0.001, OR 69, 95% CI 7.8-610) and contrast enhancement (p = 0.007, OR 16.5, 95% CI 2.3-121) were found to be significant predictors of the presence of IIAs. In the individuals with IE who underwent DSA and MRI, we found that neuroimaging characteristics, such as sulcal SWI lesion with or without contrast enhancement, are associated with the presence of IIA. © 2017 S. Karger AG, Basel.

  5. Directed self-assembly of diblock copolymers in cylindrical confinement: effect of underfilling and air-polymer interactions on configurations

    NASA Astrophysics Data System (ADS)

    Carpenter, Corinne L.; Delaney, Kris T.; Laachi, Nabil; Fredrickson, Glenn H.

    2015-03-01

    Directed self-assembly (DSA) of block copolymers has attracted attention for its use as a simple, cost- effective patterning tool for creating vertical interconnect access (VIA) channels in nanoelectronic devices.1, 2 This technique supplements existing lithographic technologies to allow for the creation of high-resolution cylindrical holes whose diameter and placement can be precisely controlled. In this study, we use self-consistent field theory (SCFT) simulations to investigate the equilibrium configurations of under-filled DSA systems with air-polymer interactions. We report on a series of SCFT simulations of our three species (PMMA-b-PS diblock and air) model in cylindrical confinement to explore the role of template diameter, under-fill fraction (i.e. volume fraction of air), air-polymer surface interaction and polymer-side wall/substrate interactions on equilibrium morphologies in an under-filled template with a free top surface. We identify parameters and system configurations where a meniscus appears and explore cases with PMMA-attractive, PS-attractive, and all-neutral walls to understand the effects of wall properties on meniscus geometry and DSA morphology. An important outcome is an understanding of the parameters that control the contact angle of the meniscus with the wall, as it is one of the simplest quantitative measures of the meniscus shape. Ultimately, we seek to identify DSA formulations, templates, and surface treatments with predictable central cylinder diameter and a shallow contact angle, as these factors would facilitate broad process windows and ease of manufacturing.

  6. Successful Renal Transplantation Across HLA Barrier: Report from India.

    PubMed

    Aggarwal, G; Tiwari, A K; Dorwal, P; Chauhan, R; Arora, D; Dara, R C; Kher, V

    2017-01-01

    Organ donors are sometimes found "unsuitable" due to the presence of donor-specific anti-HLA antibodies in the recipient. In recent years, improved desensitization protocols have successfully helped to overcome HLA incompatibility hurdle. We present three cases where optimum desensitization was achieved in patients with the donor-specific anti-HLA antibody (DSA) leading to successful renal transplantation. All patient-donor pair underwent HLA typing, complement dependent cytotoxicity crossmatch (CDC-XM), flow cytometry XM (FC-XM), and panel reactive antibody. If any of the three tests was positive, single antigen bead assay was performed to determine the specificity of the anti-HLA antibody (s). Patients with DSA were offered organ-swap or anti-HLA antibody desensitization followed by transplantation. Desensitization protocol consisted of single dose rituximab and cascade plasmapheresis (CP) along with standard triple immunosuppression. The target DSA mean fluorescence index (MFI) was <500, along with negative CDC-XM and FC-XM for both T- and B-cells. Three patients with anti-HLA DSA, who did not find a suitable match in organ swap program, consented to anti-HLA antibody desensitization, followed by transplantation. Mean pre-desensitization antibody MFI was 1740 (1422-2280). Mean number of CP required to achieve the target MFI was 2.3 (2-3). All the three patients are on regular follow-up and have normal renal function test at a mean follow-up of 8 months. This report underlines successful application of desensitization protocol leading to successful HLA-antibody incompatible renal transplants and their continued normal renal functions.

  7. Identification of Single- and Multiple-Class Specific Signature Genes from Gene Expression Profiles by Group Marker Index

    PubMed Central

    Tsai, Yu-Shuen; Aguan, Kripamoy; Pal, Nikhil R.; Chung, I-Fang

    2011-01-01

    Informative genes from microarray data can be used to construct prediction model and investigate biological mechanisms. Differentially expressed genes, the main targets of most gene selection methods, can be classified as single- and multiple-class specific signature genes. Here, we present a novel gene selection algorithm based on a Group Marker Index (GMI), which is intuitive, of low-computational complexity, and efficient in identification of both types of genes. Most gene selection methods identify only single-class specific signature genes and cannot identify multiple-class specific signature genes easily. Our algorithm can detect de novo certain conditions of multiple-class specificity of a gene and makes use of a novel non-parametric indicator to assess the discrimination ability between classes. Our method is effective even when the sample size is small as well as when the class sizes are significantly different. To compare the effectiveness and robustness we formulate an intuitive template-based method and use four well-known datasets. We demonstrate that our algorithm outperforms the template-based method in difficult cases with unbalanced distribution. Moreover, the multiple-class specific genes are good biomarkers and play important roles in biological pathways. Our literature survey supports that the proposed method identifies unique multiple-class specific marker genes (not reported earlier to be related to cancer) in the Central Nervous System data. It also discovers unique biomarkers indicating the intrinsic difference between subtypes of lung cancer. We also associate the pathway information with the multiple-class specific signature genes and cross-reference to published studies. We find that the identified genes participate in the pathways directly involved in cancer development in leukemia data. Our method gives a promising way to find genes that can involve in pathways of multiple diseases and hence opens up the possibility of using an existing drug on other diseases as well as designing a single drug for multiple diseases. PMID:21909426

  8. Content-based video retrieval by example video clip

    NASA Astrophysics Data System (ADS)

    Dimitrova, Nevenka; Abdel-Mottaleb, Mohamed

    1997-01-01

    This paper presents a novel approach for video retrieval from a large archive of MPEG or Motion JPEG compressed video clips. We introduce a retrieval algorithm that takes a video clip as a query and searches the database for clips with similar contents. Video clips are characterized by a sequence of representative frame signatures, which are constructed from DC coefficients and motion information (`DC+M' signatures). The similarity between two video clips is determined by using their respective signatures. This method facilitates retrieval of clips for the purpose of video editing, broadcast news retrieval, or copyright violation detection.

  9. Clinical utility of time-resolved imaging of contrast kinetics (TRICKS) magnetic resonance angiography for infrageniculate arterial occlusive disease.

    PubMed

    Mell, Matthew; Tefera, Girma; Thornton, Frank; Siepman, David; Turnipseed, William

    2007-03-01

    The diagnostic accuracy of magnetic resonance angiography (MRA) in the infrapopliteal arterial segment is not well defined. This study evaluated the clinical utility and diagnostic accuracy of time-resolved imaging of contrast kinetics (TRICKS) MRA compared with digital subtraction contrast angiography (DSA) in planning for percutaneous interventions of popliteal and infrapopliteal arterial occlusive disease. Patients who underwent percutaneous lower extremity interventions for popliteal or tibial occlusive disease were identified for this study. Preprocedural TRICKS MRA was performed with 1.5 Tesla (GE Healthcare, Waukesha, Wis) magnetic resonance imaging scanners with a flexible peripheral vascular coil, using the TRICKS technique with gadodiamide injection. DSA was performed using standard techniques in angiography suite with a 15-inch image intensifier. DSA was considered the gold standard. The MRA and DSA were then evaluated in a blinded fashion by a radiologist and a vascular surgeon. The popliteal artery and tibioperoneal trunk were evaluated separately, and the tibial arteries were divided into proximal, mid, and distal segments. Each segment was interpreted as normal (0% to 49% stenosis), stenotic (50% to 99% stenosis), or occluded (100%). Lesion morphology was classified according to the TransAtlantic Inter-Society Consensus (TASC). We calculated concordance between the imaging studies and the sensitivity and specificity of MRA. The clinical utility of MRA was also assessed in terms of identifying arterial access site as well as predicting technical success of the percutaneous treatment. Comparisons were done on 150 arterial segments in 30 limbs of 27 patients. When evaluated by TASC classification, TRICKS MRA correlated with DSA in 83% of the popliteal and in 88% of the infrapopliteal segments. MRA correctly identified significant disease of the popliteal artery with a sensitivity of 94% and a specificity of 92%, and of the tibial arteries with a sensitivity of 100% and specificity of 84%. When used to evaluate for stenosis vs occlusion, MRA interpretation agreed with DSA 90% of the time. Disagreement occurred in 15 arterial segments, most commonly in distal tibioperoneal arteries. MRA misdiagnosed occlusion for stenosis in 11 of 15 segments, and stenosis for occlusion in four of 15 segments. Arterial access was accurately planned based on preprocedural MRA findings in 29 of 30 patients. MRA predicted technical success 83% of the time. Five technical failures were due to inability to cross arterial occlusions, all accurately identified by MRA. TRICKS MRA is an accurate method of evaluating patients for popliteal and infrapopliteal arterial occlusive disease and can be used for planning percutaneous interventions.

  10. Effects of non-ionic iodinated contrast media on patient heart rate and pressures during intra-cardiac or intra-arterial injection.

    PubMed

    Schmid, Isabelle; Didier, Dominique; Pfammatter, Thomas; Garachemani, Ali; Fleisch, Martin; Kirchin, Miles A; Meier, Bernhard

    2007-06-12

    To compare the effects on heart rate (HR), on left ventricular (LV) or arterial pressures, and the general safety of a non-ionic low-osmolar contrast medium (CM) and a non-ionic iso-osmolar CM in patients undergoing cardiac angiography (CA) or peripheral intra-arterial digital subtraction angiography (IA-DSA). Two double-blind, randomized studies were conducted in 216 patients who underwent CA (n=120) or peripheral IA-DSA (n=96). Patients referred for CA received a low-osmolar monomeric CM (iomeprol-350, n=60) or an iso-osmolar dimeric CM (iodixanol-320; n=60). HR and LV peak systolic and end-diastolic pressures were determined before and after the first injection during left and right coronary arteriography and left ventriculography. Monitoring for all types of adverse event (AE) was performed for 24 h following the procedure. t-tests were performed to compare CM for effects on HR. Patients referred for IA-DSA received iomeprol-300 (n=49) or iodixanol-320 (n=47). HR and arterial blood pressure (BP) were evaluated before and after the first 4 injections. Monitoring for AE was performed for 4 h following the procedure. Repeated-measures ANOVA was used to compare mean HR changes across the first 4 injections, whereas changes after the first injection were compared using t-tests. No significant differences were noted between iomeprol and iodixanol in terms of mean changes in HR during left coronary arteriography (p=0.8), right coronary arteriography (p=0.9), and left ventriculography (p=0.8). In patients undergoing IA-DSA, no differences between CM were noted for effects on mean HR after the first injection (p=0.6) or across the first 4 injections (p=0.2). No significant differences (p>0.05) were noted in terms of effects on arterial BP in either study or on LV pressures in patients undergoing CA. Non-serious AE considered possibly CM-related (primarily headache and events affecting the cardiovascular and digestive systems) were reported more frequently by patients undergoing CA and more frequently after iodixanol (14/60 [23.3%] and 2/47 [4.3%]; CA and IA-DSA, respectively) than iomeprol (10/60 [16.7%] and 1/49 [2%], respectively). Iomeprol and iodixanol are safe and have equally negligible effects on HR and LV pressures or arterial BP during and after selective intra-cardiac injection and peripheral IA-DSA. Iomeprol and iodixanol are safe and equally well tolerated with regard to cardiac rhythm and clinical preference should be based on diagnostic image quality alone.

  11. Performance Analysis of Blind Subspace-Based Signature Estimation Algorithms for DS-CDMA Systems with Unknown Correlated Noise

    NASA Astrophysics Data System (ADS)

    Zarifi, Keyvan; Gershman, Alex B.

    2006-12-01

    We analyze the performance of two popular blind subspace-based signature waveform estimation techniques proposed by Wang and Poor and Buzzi and Poor for direct-sequence code division multiple-access (DS-CDMA) systems with unknown correlated noise. Using the first-order perturbation theory, analytical expressions for the mean-square error (MSE) of these algorithms are derived. We also obtain simple high SNR approximations of the MSE expressions which explicitly clarify how the performance of these techniques depends on the environmental parameters and how it is related to that of the conventional techniques that are based on the standard white noise assumption. Numerical examples further verify the consistency of the obtained analytical results with simulation results.

  12. Repetitive element signature-based visualization, distance computation, and classification of 1766 microbial genomes.

    PubMed

    Lee, Kang-Hoon; Shin, Kyung-Seop; Lim, Debora; Kim, Woo-Chan; Chung, Byung Chang; Han, Gyu-Bum; Roh, Jeongkyu; Cho, Dong-Ho; Cho, Kiho

    2015-07-01

    The genomes of living organisms are populated with pleomorphic repetitive elements (REs) of varying densities. Our hypothesis that genomic RE landscapes are species/strain/individual-specific was implemented into the Genome Signature Imaging system to visualize and compute the RE-based signatures of any genome. Following the occurrence profiling of 5-nucleotide REs/words, the information from top-50 frequency words was transformed into a genome-specific signature and visualized as Genome Signature Images (GSIs), using a CMYK scheme. An algorithm for computing distances among GSIs was formulated using the GSIs' variables (word identity, frequency, and frequency order). The utility of the GSI-distance computation system was demonstrated with control genomes. GSI-based computation of genome-relatedness among 1766 microbes (117 archaea and 1649 bacteria) identified their clustering patterns; although the majority paralleled the established classification, some did not. The Genome Signature Imaging system, with its visualization and distance computation functions, enables genome-scale evolutionary studies involving numerous genomes with varying sizes. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Hyperspectral target detection analysis of a cluttered scene from a virtual airborne sensor platform using MuSES

    NASA Astrophysics Data System (ADS)

    Packard, Corey D.; Viola, Timothy S.; Klein, Mark D.

    2017-10-01

    The ability to predict spectral electro-optical (EO) signatures for various targets against realistic, cluttered backgrounds is paramount for rigorous signature evaluation. Knowledge of background and target signatures, including plumes, is essential for a variety of scientific and defense-related applications including contrast analysis, camouflage development, automatic target recognition (ATR) algorithm development and scene material classification. The capability to simulate any desired mission scenario with forecast or historical weather is a tremendous asset for defense agencies, serving as a complement to (or substitute for) target and background signature measurement campaigns. In this paper, a systematic process for the physical temperature and visible-through-infrared radiance prediction of several diverse targets in a cluttered natural environment scene is presented. The ability of a virtual airborne sensor platform to detect and differentiate targets from a cluttered background, from a variety of sensor perspectives and across numerous wavelengths in differing atmospheric conditions, is considered. The process described utilizes the thermal and radiance simulation software MuSES and provides a repeatable, accurate approach for analyzing wavelength-dependent background and target (including plume) signatures in multiple band-integrated wavebands (multispectral) or hyperspectrally. The engineering workflow required to combine 3D geometric descriptions, thermal material properties, natural weather boundary conditions, all modes of heat transfer and spectral surface properties is summarized. This procedure includes geometric scene creation, material and optical property attribution, and transient physical temperature prediction. Radiance renderings, based on ray-tracing and the Sandford-Robertson BRDF model, are coupled with MODTRAN for the inclusion of atmospheric effects. This virtual hyperspectral/multispectral radiance prediction methodology has been extensively validated and provides a flexible process for signature evaluation and algorithm development.

  14. Authentication Based on Pole-zero Models of Signature Velocity

    PubMed Central

    Rashidi, Saeid; Fallah, Ali; Towhidkhah, Farzad

    2013-01-01

    With the increase of communication and financial transaction through internet, on-line signature verification is an accepted biometric technology for access control and plays a significant role in authenticity and authorization in modernized society. Therefore, fast and precise algorithms for the signature verification are very attractive. The goal of this paper is modeling of velocity signal that pattern and properties is stable for persons. With using pole-zero models based on discrete cosine transform, precise method is proposed for modeling and then features is founded from strokes. With using linear, parzen window and support vector machine classifiers, the signature verification technique was tested with a large number of authentic and forgery signatures and has demonstrated the good potential of this technique. The signatures are collected from three different database include a proprietary database, the SVC2004 and the Sabanci University signature database benchmark databases. Experimental results based on Persian, SVC2004 and SUSIG databases show that our method achieves an equal error rate of 5.91%, 5.62% and 3.91% in the skilled forgeries, respectively. PMID:24696797

  15. SMV⊥: Simplex of maximal volume based upon the Gram-Schmidt process

    NASA Astrophysics Data System (ADS)

    Salazar-Vazquez, Jairo; Mendez-Vazquez, Andres

    2015-10-01

    In recent years, different algorithms for Hyperspectral Image (HI) analysis have been introduced. The high spectral resolution of these images allows to develop different algorithms for target detection, material mapping, and material identification for applications in Agriculture, Security and Defense, Industry, etc. Therefore, from the computer science's point of view, there is fertile field of research for improving and developing algorithms in HI analysis. In some applications, the spectral pixels of a HI can be classified using laboratory spectral signatures. Nevertheless, for many others, there is no enough available prior information or spectral signatures, making any analysis a difficult task. One of the most popular algorithms for the HI analysis is the N-FINDR because it is easy to understand and provides a way to unmix the original HI in the respective material compositions. The N-FINDR is computationally expensive and its performance depends on a random initialization process. This paper proposes a novel idea to reduce the complexity of the N-FINDR by implementing a bottom-up approach based in an observation from linear algebra and the use of the Gram-Schmidt process. Therefore, the Simplex of Maximal Volume Perpendicular (SMV⊥) algorithm is proposed for fast endmember extraction in hyperspectral imagery. This novel algorithm has complexity O(n) with respect to the number of pixels. In addition, the evidence shows that SMV⊥ calculates a bigger volume, and has lower computational time complexity than other poular algorithms on synthetic and real scenarios.

  16. Can SNOMED CT be squeezed without losing its shape?

    PubMed

    López-García, Pablo; Schulz, Stefan

    2016-09-21

    In biomedical applications where the size and complexity of SNOMED CT become problematic, using a smaller subset that can act as a reasonable substitute is usually preferred. In a special class of use cases-like ontology-based quality assurance, or when performing scaling experiments for real-time performance-it is essential that modules show a similar shape than SNOMED CT in terms of concept distribution per sub-hierarchy. Exactly how to extract such balanced modules remains unclear, as most previous work on ontology modularization has focused on other problems. In this study, we investigate to what extent extracting balanced modules that preserve the original shape of SNOMED CT is possible, by presenting and evaluating an iterative algorithm. We used a graph-traversal modularization approach based on an input signature. To conform to our definition of a balanced module, we implemented an iterative algorithm that carefully bootstraped and dynamically adjusted the signature at each step. We measured the error for each sub-hierarchy and defined convergence as a residual sum of squares <1. Using 2000 concepts as an initial signature, our algorithm converged after seven iterations and extracted a module 4.7 % the size of SNOMED CT. Seven sub-hierarhies were either over or under-represented within a range of 1-8 %. Our study shows that balanced modules from large terminologies can be extracted using ontology graph-traversal modularization techniques under certain conditions: that the process is repeated a number of times, the input signature is dynamically adjusted in each iteration, and a moderate under/over-representation of some hierarchies is tolerated. In the case of SNOMED CT, our results conclusively show that it can be squeezed to less than 5 % of its size without any sub-hierarchy losing its shape more than 8 %, which is likely sufficient in most use cases.

  17. Correspondence regarding Zhong et al., BMC Bioinformatics 2013 Mar 7;14:89.

    PubMed

    Kuhn, Alexandre

    2014-11-28

    Computational expression deconvolution aims to estimate the contribution of individual cell populations to expression profiles measured in samples of heterogeneous composition. Zhong et al. recently proposed Digital Sorting Algorithm (BMC Bioinformatics 2013 Mar 7;14:89) and showed that they could accurately estimate population-specific expression levels and expression differences between two populations. They compared DSA with Population-Specific Expression Analysis (PSEA), a previous deconvolution method that we developed to detect expression changes occurring within the same population between two conditions (e.g. disease versus non-disease). However, Zhong et al. compared PSEA-derived specific expression levels across different cell populations. Specific expression levels obtained with PSEA cannot be directly compared across different populations as they are on a relative scale. They are accurate as we demonstrate by deconvolving the same dataset used by Zhong et al. and, importantly, allow for comparison of population-specific expression across conditions.

  18. A new bio-inspired, population-level approach to the socioeconomic evolution of dynamic spectrum access services

    NASA Astrophysics Data System (ADS)

    Horvath, Denis; Gazda, Juraj; Brutovsky, Branislav

    Evolutionary species and quasispecies models provide the universal and flexible basis for a large-scale description of the dynamics of evolutionary systems, which can be built conceived as a constraint satisfaction dynamics. It represents a general framework to design and study many novel, technologically contemporary models and their variants. Here, we apply the classical quasispecies concept to model the emerging dynamic spectrum access (DSA) markets. The theory describes the mechanisms of mimetic transfer, competitive interactions between socioeconomic strata of the end-users, their perception of the utility and inter-operator switching in the variable technological environments of the operators offering the wireless spectrum services. The algorithmization and numerical modeling demonstrate the long-term evolutionary socioeconomic changes which reflect the end-user preferences and results of the majorization of their irrational decisions in the same manner as the prevailing tendencies which are embodied in the efficient market hypothesis.

  19. An Iterative Time Windowed Signature Algorithm for Time Dependent Transcription Module Discovery

    PubMed Central

    Meng, Jia; Gao, Shou-Jiang; Huang, Yufei

    2010-01-01

    An algorithm for the discovery of time varying modules using genome-wide expression data is present here. When applied to large-scale time serious data, our method is designed to discover not only the transcription modules but also their timing information, which is rarely annotated by the existing approaches. Rather than assuming commonly defined time constant transcription modules, a module is depicted as a set of genes that are co-regulated during a specific period of time, i.e., a time dependent transcription module (TDTM). A rigorous mathematical definition of TDTM is provided, which is serve as an objective function for retrieving modules. Based on the definition, an effective signature algorithm is proposed that iteratively searches the transcription modules from the time series data. The proposed method was tested on the simulated systems and applied to the human time series microarray data during Kaposi's sarcoma-associated herpesvirus (KSHV) infection. The result has been verified by Expression Analysis Systematic Explorer. PMID:21552463

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    I. W. Ginsberg

    Multiresolutional decompositions known as spectral fingerprints are often used to extract spectral features from multispectral/hyperspectral data. In this study, the authors investigate the use of wavelet-based algorithms for generating spectral fingerprints. The wavelet-based algorithms are compared to the currently used method, traditional convolution with first-derivative Gaussian filters. The comparison analyses consists of two parts: (a) the computational expense of the new method is compared with the computational costs of the current method and (b) the outputs of the wavelet-based methods are compared with those of the current method to determine any practical differences in the resulting spectral fingerprints. The resultsmore » show that the wavelet-based algorithms can greatly reduce the computational expense of generating spectral fingerprints, while practically no differences exist in the resulting fingerprints. The analysis is conducted on a database of hyperspectral signatures, namely, Hyperspectral Digital Image Collection Experiment (HYDICE) signatures. The reduction in computational expense is by a factor of about 30, and the average Euclidean distance between resulting fingerprints is on the order of 0.02.« less

  1. ArrayVigil: a methodology for statistical comparison of gene signatures using segregated-one-tailed (SOT) Wilcoxon's signed-rank test.

    PubMed

    Khan, Haseeb Ahmad

    2005-01-28

    Due to versatile diagnostic and prognostic fidelity molecular signatures or fingerprints are anticipated as the most powerful tools for cancer management in the near future. Notwithstanding the experimental advancements in microarray technology, methods for analyzing either whole arrays or gene signatures have not been firmly established. Recently, an algorithm, ArraySolver has been reported by Khan for two-group comparison of microarray gene expression data using two-tailed Wilcoxon signed-rank test. Most of the molecular signatures are composed of two sets of genes (hybrid signatures) wherein up-regulation of one set and down-regulation of the other set collectively define the purpose of a gene signature. Since the direction of a selected gene's expression (positive or negative) with respect to a particular disease condition is known, application of one-tailed statistics could be a more relevant choice. A novel method, ArrayVigil, is described for comparing hybrid signatures using segregated-one-tailed (SOT) Wilcoxon signed-rank test and the results compared with integrated-two-tailed (ITT) procedures (SPSS and ArraySolver). ArrayVigil resulted in lower P values than those obtained from ITT statistics while comparing real data from four signatures.

  2. [Orthogonal Vector Projection Algorithm for Spectral Unmixing].

    PubMed

    Song, Mei-ping; Xu, Xing-wei; Chang, Chein-I; An, Ju-bai; Yao, Li

    2015-12-01

    Spectrum unmixing is an important part of hyperspectral technologies, which is essential for material quantity analysis in hyperspectral imagery. Most linear unmixing algorithms require computations of matrix multiplication and matrix inversion or matrix determination. These are difficult for programming, especially hard for realization on hardware. At the same time, the computation costs of the algorithms increase significantly as the number of endmembers grows. Here, based on the traditional algorithm Orthogonal Subspace Projection, a new method called. Orthogonal Vector Projection is prompted using orthogonal principle. It simplifies this process by avoiding matrix multiplication and inversion. It firstly computes the final orthogonal vector via Gram-Schmidt process for each endmember spectrum. And then, these orthogonal vectors are used as projection vector for the pixel signature. The unconstrained abundance can be obtained directly by projecting the signature to the projection vectors, and computing the ratio of projected vector length and orthogonal vector length. Compared to the Orthogonal Subspace Projection and Least Squares Error algorithms, this method does not need matrix inversion, which is much computation costing and hard to implement on hardware. It just completes the orthogonalization process by repeated vector operations, easy for application on both parallel computation and hardware. The reasonability of the algorithm is proved by its relationship with Orthogonal Sub-space Projection and Least Squares Error algorithms. And its computational complexity is also compared with the other two algorithms', which is the lowest one. At last, the experimental results on synthetic image and real image are also provided, giving another evidence for effectiveness of the method.

  3. Correction for reflected sky radiance in low-altitude coastal hyperspectral images.

    PubMed

    Kim, Minsu; Park, Joong Yong; Kopilevich, Yuri; Tuell, Grady; Philpot, William

    2013-11-10

    Low-altitude coastal hyperspectral imagery is sensitive to reflections of sky radiance at the water surface. Even in the absence of sun glint, and for a calm water surface, the wide range of viewing angles may result in pronounced, low-frequency variations of the reflected sky radiance across the scan line depending on the solar position. The variation in reflected sky radiance can be obscured by strong high-spatial-frequency sun glint and at high altitude by path radiance. However, at low altitudes, the low-spatial-frequency sky radiance effect is frequently significant and is not removed effectively by the typical corrections for sun glint. The reflected sky radiance from the water surface observed by a low-altitude sensor can be modeled in the first approximation as the sum of multiple-scattered Rayleigh path radiance and the single-scattered direct-solar-beam radiance by the aerosol in the lower atmosphere. The path radiance from zenith to the half field of view (FOV) of a typical airborne spectroradiometer has relatively minimal variation and its reflected radiance to detector array results in a flat base. Therefore the along-track variation is mostly contributed by the forward single-scattered solar-beam radiance. The scattered solar-beam radiances arrive at the water surface with different incident angles. Thus the reflected radiance received at the detector array corresponds to a certain scattering angle, and its variation is most effectively parameterized using the downward scattering angle (DSA) of the solar beam. Computation of the DSA must account for the roll, pitch, and heading of the platform and the viewing geometry of the sensor along with the solar ephemeris. Once the DSA image is calculated, the near-infrared (NIR) radiance from selected water scan lines are compared, and a relationship between DSA and NIR radiance is derived. We then apply the relationship to the entire DSA image to create an NIR reference image. Using the NIR reference image and an atmospheric spectral reflectance look-up table, the low spatial frequency variation of the water surface-reflected atmospheric contribution is removed.

  4. A ROLE FOR ANTIBODIES TO HLA, COLLAGEN-V AND K-α1-TUBULIN IN ANTIBODY MEDIATED REJECTION AND CARDIAC ALLOGRAFT VASCULOPATHY

    PubMed Central

    Nath, Dilip S.; Tiriveedhi, Venkataswarup; Bash, Haseeb Ilias; Phelan, Donna; Moazami, Nader; Ewald, Gregory A.; Mohanakumar, T.

    2013-01-01

    Background We determined role of donor specific antibodies (DSA) and antibodies (Abs) to self-antigens, collagen-V (Col-V) and K-α1-Tubulin (KAT) in pathogenesis of acute antibody mediated rejection (AMR) and cardiac allograft vasculopathy (CAV) following human heart transplantation (HTx). Methods 137 HTx recipients - 60 early period (≤ 12months) and 77 late period (> 12months) patients were enrolled. Circulating DSA was determined using LUMINEX. Abs against Col-I, II, IV, V and KAT were measured using ELISA. Frequency of CD4+T helper cells (CD4+Th) secreting IFN-γ, IL-5, IL-10 or IL-17 specific to self-antigens were determined using ELISPOT. Results A significant association between AMR and DSA was demonstrated. Development of DSA in AMR patients correlated well with the development of auto-Abs to Col-V(AMR(+): 383±72μg/mL, AMR(−): 172±49μg/mL, p=0.033) and KAT (AMR(+): 252±49μg/mL, AMR(−): 61±21μg/mL, p=0.014). Patients who developed AMR demonstrated increased frequencies of CD4+Th secreting IFN-γ and IL-5 with reduction in IL-10 specific for Col-V/KAT. Patients diagnosed with CAV also developed DSA and auto-Abs to Col-V (CAV(+): 835±142μg/mL, CAV(−): 242±68μg/mL, p=0.025) and KAT (CAV(+): 768±206μg/mL, CAV(−): 196±72μg/mL, p=0.001) with increased frequencies of CD4+Th secreting IL-17 with reduction in IL-10 specific for Col-V/KAT. Conclusions Development of Abs to HLA and self-antigens are associated with increases in CD4+Th secreting IFN-γ and IL-5 in AMR and IL-17 in CAV, with reduction in CD4+Th secreting IL-10 in both AMR and CAV. PMID:21383658

  5. Artefacts induced by coiled intracranial aneurysms on 3.0-Tesla versus 1.5-Tesla MR angiography--An in vivo and in vitro study.

    PubMed

    Schaafsma, Joanna D; Velthuis, Birgitta K; Vincken, Koen L; de Kort, Gerard A P; Rinkel, Gabriel J E; Bartels, Lambertus W

    2014-05-01

    To compare metal-induced artefacts from coiled intracranial aneurysms on 3.0-Tesla and 1.5-Tesla magnetic resonance angiography (MRA), since concerns persist on artefact enlargement at 3.0Tesla. We scanned 19 patients (mean age 53; 16 women) with 20 saccular aneurysms treated with coils only, at 1.5 and 3.0Tesla according to standard clinical 3D TOF-MRA protocols containing a shorter echo-time but weaker read-out gradient at 3.0Tesla in addition to intra-arterial digital subtraction angiography (IA-DSA). Per modality two neuro-radiologists assessed the occlusion status, measured residual flow, and indicated whether coil artefacts disturbed this assessment on MRA. We assessed relative risks for disturbance by coil artefacts, weighted kappa's for agreement on occlusion levels, and we compared remnant sizes. For artefact measurements, a coil model was created and scanned with the same protocols followed by 2D MR scans with variation of echo-time and read-out gradient strength. Coil artefacts disturbed assessments less frequently at 3.0Tesla than at 1.5Tesla (RR: 0.3; 95%CI: 0.1-0.8). On 3.0-Tesla MRA, remnants were larger than on 1.5-Tesla MRA (difference: 0.7mm; 95%CI: 0.3-1.1) and larger than on IA-DSA (difference: 1.0mm; 95%CI: 0.6-1.5) with similar agreement on occlusion levels with IA-DSA for both field strengths (κ 0.53; 95%CI: 0.23-0.84 for 1.5-Tesla MRA and IA-DSA; κ 0.47; 95%CI: 0.19-0.76 for 3.0-Tesla MRA and IA-DSA). Coil model artefacts were smaller at 3.0Tesla than at 1.5Tesla. The echo-time influenced artefact size more than the read-out gradient. Artefacts were not larger, but smaller at 3.0Tesla because a shorter echo-time at 3.0Tesla negated artefact enlargement. Despite smaller artefacts and larger remnants at 3.0Tesla, occlusion levels were similar for both field strengths. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Exploring a Physically Based Tool for Lightning Cessation: A Preliminary Study

    NASA Technical Reports Server (NTRS)

    Schultz, Elise V.; Petersen, Walter a.; Carey, Lawrence D.; Deierling, Wiebke

    2010-01-01

    The University of Alabama in Huntsville (UA Huntsville) and NASA's Marshall Space Flight Center are collaborating with the 45th Weather Squadron (45WS) at Cape Canaveral Air Force Station (CCAFS) to enable improved nowcasting of lightning cessation. The project centers on use of dual-polarimetric radar capabilities, and in particular, the new C-band dual-polarimetric weather radar acquired by the 45WS. Special emphasis is placed on the development of a physically based operational algorithm to predict lightning cessation. While previous studies have developed statistically based lightning cessation algorithms, we believe that dual-polarimetric radar variables offer the possibility to improve existing algorithms through the inclusion of physically meaningful trends reflecting interactions between in-cloud electric fields and microphysics. Specifically, decades of polarimetric radar research using propagation differential phase has demonstrated the presence of distinct phase and ice crystal alignment signatures in the presence of strong electric fields associated with lightning. One question yet to be addressed is: To what extent can these ice-crystal alignment signatures be used to nowcast the cessation of lightning activity in a given storm? Accordingly, data from the UA Huntsville Advanced Radar for Meteorological and Operational Research (ARMOR) along with the North Alabama Lightning Mapping Array are used in this study to investigate the radar signatures present before and after lightning cessation. A summary of preliminary results will be presented.

  7. Exploring a Physically Based Tool for Lightning Cessation: Preliminary Results

    NASA Technical Reports Server (NTRS)

    Schultz, Elsie V.; Petersen, Walter A.; Carey, Lawrence D.; Buechler, Dennis E.; Gatlin, Patrick N.

    2010-01-01

    The University of Alabama in Huntsville (UAHuntsville) and NASA s Marshall Space Flight Center are collaborating with the 45th Weather Squadron (45WS) at Cape Canaveral Air Force Station (CCAFS) to enable improved nowcasting of lightning cessation. The project centers on use of dual-polarimetric radar capabilities, and in particular, the new C-band dual-polarimetric weather radar acquired by the 45WS. Special emphasis is placed on the development of a physically based operational algorithm to predict lightning cessation. While previous studies have developed statistically based lightning cessation algorithms, we believe that dual-polarimetric radar variables offer the possibility to improve existing algorithms through the inclusion of physically meaningful trends reflecting interactions between in-cloud electric fields and microphysics. Specifically, decades of polarimetric radar research using propagation differential phase has demonstrated the presence of distinct phase and ice crystal alignment signatures in the presence of strong electric fields associated with lightning. One question yet to be addressed is: To what extent can these ice-crystal alignment signatures be used to nowcast the cessation of lightning activity in a given storm? Accordingly, data from the UAHuntsville Advanced Radar for Meteorological and Operational Research (ARMOR) along with the North Alabama Lightning Mapping Array are used in this study to investigate the radar signatures present before and after lightning cessation. A summary of preliminary results will be presented.

  8. Target detection using the background model from the topological anomaly detection algorithm

    NASA Astrophysics Data System (ADS)

    Dorado Munoz, Leidy P.; Messinger, David W.; Ziemann, Amanda K.

    2013-05-01

    The Topological Anomaly Detection (TAD) algorithm has been used as an anomaly detector in hyperspectral and multispectral images. TAD is an algorithm based on graph theory that constructs a topological model of the background in a scene, and computes an anomalousness ranking for all of the pixels in the image with respect to the background in order to identify pixels with uncommon or strange spectral signatures. The pixels that are modeled as background are clustered into groups or connected components, which could be representative of spectral signatures of materials present in the background. Therefore, the idea of using the background components given by TAD in target detection is explored in this paper. In this way, these connected components are characterized in three different approaches, where the mean signature and endmembers for each component are calculated and used as background basis vectors in Orthogonal Subspace Projection (OSP) and Adaptive Subspace Detector (ASD). Likewise, the covariance matrix of those connected components is estimated and used in detectors: Constrained Energy Minimization (CEM) and Adaptive Coherence Estimator (ACE). The performance of these approaches and the different detectors is compared with a global approach, where the background characterization is derived directly from the image. Experiments and results using self-test data set provided as part of the RIT blind test target detection project are shown.

  9. Yield and accuracy of urgent combined carotid/transcranial ultrasound testing in acute cerebral ischemia.

    PubMed

    Chernyshev, Oleg Y; Garami, Zsolt; Calleja, Sergio; Song, Joon; Campbell, Morgan S; Noser, Elizabeth A; Shaltoni, Hashem; Chen, Chin-I; Iguchi, Yasuyuki; Grotta, James C; Alexandrov, Andrei V

    2005-01-01

    We routinely perform an urgent bedside neurovascular ultrasound examination (NVUE) with carotid/vertebral duplex and transcranial Doppler (TCD) in patients with acute cerebral ischemia. We aimed to determine the yield and accuracy of NVUE to identify lesions amenable for interventional treatment (LAITs). NVUE was performed with portable carotid duplex and TCD using standardized fast-track (<15 minutes) insonation protocols. Digital subtraction angiography (DSA) was the gold standard for identifying LAIT. These lesions were defined as proximal intra- or extracranial occlusions, near-occlusions, > or =50% stenoses or thrombus in the symptomatic artery. One hundred and fifty patients (70 women, mean age 66+/-15 years) underwent NVUE at median 128 minutes after symptom onset. Fifty-four patients (36%) received intravenous or intra-arterial thrombolysis (median National Institutes of Health Stroke Scale (NIHSS) score 14, range 4 to 29; 81% had NIHSS > or =10 points). NVUE demonstrated LAITs in 98% of patients eligible for thrombolysis, 76% of acute stroke patients ineligible for thrombolysis (n=63), and 42% in patients with transient ischemic attack (n=33), P<0.001. Urgent DSA was performed in 30 patients on average 230 minutes after NVUE. Compared with DSA, NVUE predicted LAIT presence with 100% sensitivity and 100% specificity, although individual accuracy parameters for TCD and carotid duplex specific to occlusion location ranged 75% to 96% because of the presence of tandem lesions and 10% rate of no temporal windows. Bedside neurovascular ultrasound examination, combining carotid/vertebral duplex with TCD yields a substantial proportion of LAITs in excellent agreement with urgent DSA.

  10. [Myocardial perfusion imaging by digital subtraction angiography].

    PubMed

    Kadowaki, H; Ishikawa, K; Ogai, T; Katori, R

    1986-03-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; at the R wave of the electrocardiogram, 100 msec before the R wave, and 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Diffusive Shock Acceleration and Reconnection Acceleration Processes

    NASA Astrophysics Data System (ADS)

    Zank, G. P.; Hunana, P.; Mostafavi, P.; Le Roux, J. A.; Li, Gang; Webb, G. M.; Khabarova, O.; Cummings, A.; Stone, E.; Decker, R.

    2015-12-01

    Shock waves, as shown by simulations and observations, can generate high levels of downstream vortical turbulence, including magnetic islands. We consider a combination of diffusive shock acceleration (DSA) and downstream magnetic-island-reconnection-related processes as an energization mechanism for charged particles. Observations of electron and ion distributions downstream of interplanetary shocks and the heliospheric termination shock (HTS) are frequently inconsistent with the predictions of classical DSA. We utilize a recently developed transport theory for charged particles propagating diffusively in a turbulent region filled with contracting and reconnecting plasmoids and small-scale current sheets. Particle energization associated with the anti-reconnection electric field, a consequence of magnetic island merging, and magnetic island contraction, are considered. For the former only, we find that (i) the spectrum is a hard power law in particle speed, and (ii) the downstream solution is constant. For downstream plasmoid contraction only, (i) the accelerated spectrum is a hard power law in particle speed; (ii) the particle intensity for a given energy peaks downstream of the shock, and the distance to the peak location increases with increasing particle energy, and (iii) the particle intensity amplification for a particular particle energy, f(x,c/{c}0)/f(0,c/{c}0), is not 1, as predicted by DSA, but increases with increasing particle energy. The general solution combines both the reconnection-induced electric field and plasmoid contraction. The observed energetic particle intensity profile observed by Voyager 2 downstream of the HTS appears to support a particle acceleration mechanism that combines both DSA and magnetic-island-reconnection-related processes.

  12. Zbtb7a induction in alveolar macrophages is implicated in anti-HLA-mediated lung allograft rejection.

    PubMed

    Nayak, Deepak K; Zhou, Fangyu; Xu, Min; Huang, Jing; Tsuji, Moriya; Yu, Jinsheng; Hachem, Ramsey; Gelman, Andrew E; Bremner, Ross M; Smith, Michael A; Mohanakumar, Thalachallour

    2017-07-12

    Chronic rejection significantly limits long-term success of solid organ transplantation. De novo donor-specific antibodies (DSAs) to mismatched donor human leukocyte antigen after human lung transplantation predispose lung grafts to chronic rejection. We sought to delineate mediators and mechanisms of DSA pathogenesis and to define early inflammatory events that trigger chronic rejection in lung transplant recipients and obliterative airway disease, a correlate of human chronic rejection, in mouse. Induction of transcription factor zinc finger and BTB domain containing protein 7a (Zbtb7a) was an early response critical in the DSA-induced chronic rejection. A cohort of human lung transplant recipients who developed DSA and chronic rejection demonstrated greater Zbtb7a expression long before clinical diagnosis of chronic rejection compared to nonrejecting lung transplant recipients with stable pulmonary function. Expression of DSA-induced Zbtb7a was restricted to alveolar macrophages (AMs), and selective disruption of Zbtb7a in AMs resulted in less bronchiolar occlusion, low immune responses to lung-restricted self-antigens, and high protection from chronic rejection in mice. Additionally, in an allogeneic cell transfer protocol, antigen presentation by AMs was Zbtb7a-dependent where AMs deficient in Zbtb7a failed to induce antibody and T cell responses. Collectively, we demonstrate that AMs play an essential role in antibody-induced pathogenesis of chronic rejection by regulating early inflammation and lung-restricted humoral and cellular autoimmunity. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  13. Blood Based Biomarkers of Early Onset Breast Cancer

    DTIC Science & Technology

    2016-12-01

    discretizes the data, and also using logistic elastic net – a form of linear regression - we were unable to build a classifier that could accurately...classifier for differentiating cases from controls off discretized data. The first pass analysis demonstrated a 35 gene signature that differentiated...to the discretized data for mRNA gene signature, the samples used to “train” were also included in the final samples used to “test” the algorithm

  14. Hemicellulose block copolymers made from woods for wide-range directed self-assembly lithography enabling wider range of applicable patterning size

    NASA Astrophysics Data System (ADS)

    Morita, Kazuyo; Yamamoto, Kimiko

    2017-03-01

    Xylan, one of hemicellulose family, block copolymer was newly developed for wide-range directed self-assembly lithography (DSA). Xylan is higher hydrophilic material because of having many hydroxy groups in one molecule. It means that xylan block copolymer has a possibility of high-chi block copolymer. Generally, DSA is focused on microphase separation for smaller size with high-chi block copolymer and not well known for larger size. In this study, xylan block copolymer was confirmed enabling wider range of patterning size, from smaller size to larger size. The key of xylan block copolymer is a new molecular structure of block copolymer and sugar chain control technology. Sugar content is the important parameter for not only micro-phase separation property but also line edge roughness (LER) and defects. Based on the sugar control technology, wide-range (hp 8.3nm to 26nm L/S and CD 10nm to 51nm hole) DSA patterning was demonstrated. Additionally it was confirmed that xylan block copolymer is suitable for sequential infiltration synthesis (SIS) process.

  15. Variance-Based Sensitivity Analysis to Support Simulation-Based Design Under Uncertainty

    DOE PAGES

    Opgenoord, Max M. J.; Allaire, Douglas L.; Willcox, Karen E.

    2016-09-12

    Sensitivity analysis plays a critical role in quantifying uncertainty in the design of engineering systems. A variance-based global sensitivity analysis is often used to rank the importance of input factors, based on their contribution to the variance of the output quantity of interest. However, this analysis assumes that all input variability can be reduced to zero, which is typically not the case in a design setting. Distributional sensitivity analysis (DSA) instead treats the uncertainty reduction in the inputs as a random variable, and defines a variance-based sensitivity index function that characterizes the relative contribution to the output variance as amore » function of the amount of uncertainty reduction. This paper develops a computationally efficient implementation for the DSA formulation and extends it to include distributions commonly used in engineering design under uncertainty. Application of the DSA method to the conceptual design of a commercial jetliner demonstrates how the sensitivity analysis provides valuable information to designers and decision-makers on where and how to target uncertainty reduction efforts.« less

  16. Applying the Multiple Signal Classification Method to Silent Object Detection Using Ambient Noise

    NASA Astrophysics Data System (ADS)

    Mori, Kazuyoshi; Yokoyama, Tomoki; Hasegawa, Akio; Matsuda, Minoru

    2004-05-01

    The revolutionary concept of using ocean ambient noise positively to detect objects, called acoustic daylight imaging, has attracted much attention. The authors attempted the detection of a silent target object using ambient noise and a wide-band beam former consisting of an array of receivers. In experimental results obtained in air, using the wide-band beam former, we successfully applied the delay-sum array (DSA) method to detect a silent target object in an acoustic noise field generated by a large number of transducers. This paper reports some experimental results obtained by applying the multiple signal classification (MUSIC) method to a wide-band beam former to detect silent targets. The ocean ambient noise was simulated by transducers decentralized to many points in air. Both MUSIC and DSA detected a spherical target object in the noise field. The relative power levels near the target obtained with MUSIC were compared with those obtained by DSA. Then the effectiveness of the MUSIC method was evaluated according to the rate of increase in the maximum and minimum relative power levels.

  17. Variance-Based Sensitivity Analysis to Support Simulation-Based Design Under Uncertainty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Opgenoord, Max M. J.; Allaire, Douglas L.; Willcox, Karen E.

    Sensitivity analysis plays a critical role in quantifying uncertainty in the design of engineering systems. A variance-based global sensitivity analysis is often used to rank the importance of input factors, based on their contribution to the variance of the output quantity of interest. However, this analysis assumes that all input variability can be reduced to zero, which is typically not the case in a design setting. Distributional sensitivity analysis (DSA) instead treats the uncertainty reduction in the inputs as a random variable, and defines a variance-based sensitivity index function that characterizes the relative contribution to the output variance as amore » function of the amount of uncertainty reduction. This paper develops a computationally efficient implementation for the DSA formulation and extends it to include distributions commonly used in engineering design under uncertainty. Application of the DSA method to the conceptual design of a commercial jetliner demonstrates how the sensitivity analysis provides valuable information to designers and decision-makers on where and how to target uncertainty reduction efforts.« less

  18. Effect of modulation of the particle size distributions in the direct solid analysis by total-reflection X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Fernández-Ruiz, Ramón; Friedrich K., E. Josue; Redrejo, M. J.

    2018-02-01

    The main goal of this work was to investigate, in a systematic way, the influence of the controlled modulation of the particle size distribution of a representative solid sample with respect to the more relevant analytical parameters of the Direct Solid Analysis (DSA) by Total-reflection X-Ray Fluorescence (TXRF) quantitative method. In particular, accuracy, uncertainty, linearity and detection limits were correlated with the main parameters of their size distributions for the following elements; Al, Si, P, S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb. In all cases strong correlations were finded. The main conclusion of this work can be resumed as follows; the modulation of particles shape to lower average sizes next to a minimization of the width of particle size distributions, produce a strong increment of accuracy, minimization of uncertainties and limit of detections for DSA-TXRF methodology. These achievements allow the future use of the DSA-TXRF analytical methodology for development of ISO norms and standardized protocols for the direct analysis of solids by mean of TXRF.

  19. Molecular Orientation in Two Component Vapor-Deposited Glasses: Effect of Substrate Temperature and Molecular Shape

    NASA Astrophysics Data System (ADS)

    Powell, Charles; Jiang, Jing; Walters, Diane; Ediger, Mark

    Vapor-deposited glasses are widely investigated for use in organic electronics including the emitting layers of OLED devices. These materials, while macroscopically homogenous, have anisotropic packing and molecular orientation. By controlling this orientation, outcoupling efficiency can be increased by aligning the transition dipole moment of the light-emitting molecules parallel to the substrate. Light-emitting molecules are typically dispersed in a host matrix, as such, it is imperative to understand molecular orientation in two-component systems. In this study we examine two-component vapor-deposited films and the orientations of the constituent molecules using spectroscopic ellipsometry, UV-vis and IR spectroscopy. The role of temperature, composition and molecular shape as it effects molecular orientation is examined for mixtures of DSA-Ph in Alq3 and in TPD. Deposition temperature relative to the glass transition temperature of the two-component mixture is the primary controlling factor for molecular orientation. In mixtures of DSA-Ph in Alq3, the linear DSA-Ph has a horizontal orientation at low temperatures and slight vertical orientation maximized at 0.96Tg,mixture, analogous to one-component films.

  20. Optimized plasma etch window of block copolymers and neutral brush layers for enhanced direct self-assembly pattern transfer into a hardmask layer

    NASA Astrophysics Data System (ADS)

    Brakensiek, Nickolas; Xu, Kui; Sweat, Daniel; Hockey, Mary Ann

    2018-03-01

    Directed self-assembly (DSA) of block copolymers (BCPs) is one of the most promising patterning technologies for future lithography nodes. However, one of the biggest challenges to DSA is the pattern transfer by plasma etching from BCP to hardmask (HM) because the etch selectivity between BCP and neutral brush layer underneath is usually not high enough to enable robust pattern transfer. This paper will explore the plasma etch conditions of both BCPs and neutral brush layers that may improve selectivity and allow a more robust pattern transfer of DSA patterns into the hardmask layer. The plasma etching parameters that are under investigation include the selection of oxidative or reductive etch chemistries, as well as plasma gas pressure, power, and gas mixture fractions. Investigation into the relationship between BCP/neutral brush layer materials with varying chemical compositions and the plasma etching conditions will be highlighted. The culmination of this work will demonstrate important etch parameters that allow BCPs and neutral brush layers to be etched into the underlying hardmask layer with a large process window.

  1. Enhancing nuclear quadrupole resonance (NQR) signature detection leveraging interference suppression algorithms

    NASA Astrophysics Data System (ADS)

    DeBardelaben, James A.; Miller, Jeremy K.; Myrick, Wilbur L.; Miller, Joel B.; Gilbreath, G. Charmaine; Bajramaj, Blerta

    2012-06-01

    Nuclear quadrupole resonance (NQR) is a radio frequency (RF) magnetic spectroscopic technique that has been shown to detect and identify a wide range of explosive materials containing quadrupolar nuclei. The NQR response signal provides a unique signature of the material of interest. The signal is, however, very weak and can be masked by non-stationary RF interference (RFI) and thermal noise, limiting detection distance. In this paper, we investigate the bounds on the NQR detection range for ammonium nitrate. We leverage a low-cost RFI data acquisition system composed of inexpensive B-field sensing and commercial-off-the-shelf (COTS) software-defined radios (SDR). Using collected data as RFI reference signals, we apply adaptive filtering algorithms to mitigate RFI and enable NQR detection techniques to approach theoretical range bounds in tactical environments.

  2. Lidars for smoke and dust cloud diagnostics

    NASA Astrophysics Data System (ADS)

    Fujimura, S. F.; Warren, R. E.; Lutomirski, R. F.

    1980-11-01

    An algorithm that integrates a time-resolved lidar signature for use in estimating transmittance, extinction coefficient, mass concentration, and CL values generated under battlefield conditions is applied to lidar signatures measured during the DIRT-I tests. Estimates are given for the dependence of the inferred transmittance and extinction coefficient on uncertainties in parameters such as the obscurant backscatter-to-extinction ratio. The enhanced reliability in estimating transmittance through use of a target behind the obscurant cloud is discussed. It is found that the inversion algorithm can produce reliable estimates of smoke or dust transmittance and extinction from all points within the cloud for which a resolvable signal can be detected, and that a single point calibration measurement can convert the extinction values to mass concentration for each resolvable signal point.

  3. Proteus DSA control room in Mojave, CA

    NASA Image and Video Library

    2003-04-03

    Proteus DSA control room in Mojave, CA (L to R) Jean-Pierre Soucy; Amphitech International Software engineer Craig Bomben; NASA Dryden Test Pilot Pete Siebold; (with headset, at computer controls) Scaled Composites pilot Bob Roehm; New Mexico State University (NMSU) UAV Technical Analysis Application Center (TAAC) Chuck Coleman; Scaled Composites Pilot Kari Sortland; NMSU TAAC Russell Wolfe; Modern Technology Solutions, Inc. Scaled Composites' unique tandem-wing Proteus was the testbed for a series of UAV collision-avoidance flight demonstrations. An Amphitech 35GHz radar unit installed below Proteus' nose was the primary sensor for the Detect, See and Avoid tests.

  4. The DataBridge: A System For Optimizing The Use Of Dark Data From The Long Tail Of Science

    NASA Astrophysics Data System (ADS)

    Lander, H.; Rajasekar, A.

    2015-12-01

    The DataBridge is a National Science Foundation funded collaborative project (OCI-1247652, OCI-1247602, OCI-1247663) designed to assist in the discovery of dark data sets from the long tail of science. The DataBridge aims to to build queryable communities of datasets using sociometric network analysis. This approach is being tested to evaluate the ability to leverage various forms of metadata to facilitate discovery of new knowledge. Each dataset in the Databridge has an associated name space used as a first level partitioning. In addition to testing known algorithms for SNA community building, the DataBridge project has built a message-based platform that allows users to provide their own algorithms for each of the stages in the community building process. The stages are: Signature Generation (SG): An SG algorithm creates a metadata signature for a dataset. Signature algorithms might use text metadata provided by the dataset creator or derive metadata. Relevance Algorithm (RA): An RA compares a pair of datasets and produces a similarity value between 0 and 1 for the two datasets. Sociometric Network Analysis (SNA): The SNA will operate on a similarity matrix produced by an RA to partition all of the datasets in the name space into a set of clusters. These clusters represent communities of closely related datasets. The DataBridge also includes a web application that produces a visual representation of the clustering. Future work includes a more complete application that will allow different types of searching of the network of datasets. The DataBridge approach is relevant to geoscience research and informatics. In this presentation we will outline the project, illustrate the deployment of the approach, and discuss other potential applications and next steps for the research such as applying this approach to models. In addition we will explore the relevance of DataBridge to other geoscience projects such as various EarthCube Building Blocks and DIBBS projects.

  5. Limitations and requirements of content-based multimedia authentication systems

    NASA Astrophysics Data System (ADS)

    Wu, Chai W.

    2001-08-01

    Recently, a number of authentication schemes have been proposed for multimedia data such as images and sound data. They include both label based systems and semifragile watermarks. The main requirement for such authentication systems is that minor modifications such as lossy compression which do not alter the content of the data preserve the authenticity of the data, whereas modifications which do modify the content render the data not authentic. These schemes can be classified into two main classes depending on the model of image authentication they are based on. One of the purposes of this paper is to look at some of the advantages and disadvantages of these image authentication schemes and their relationship with fundamental limitations of the underlying model of image authentication. In particular, we study feature-based algorithms which generate an authentication tag based on some inherent features in the image such as the location of edges. The main disadvantage of most proposed feature-based algorithms is that similar images generate similar features, and therefore it is possible for a forger to generate dissimilar images that have the same features. On the other hand, the class of hash-based algorithms utilizes a cryptographic hash function or a digital signature scheme to reduce the data and generate an authentication tag. It inherits the security of digital signatures to thwart forgery attacks. The main disadvantage of hash-based algorithms is that the image needs to be modified in order to be made authenticatable. The amount of modification is on the order of the noise the image can tolerate before it is rendered inauthentic. The other purpose of this paper is to propose a multimedia authentication scheme which combines some of the best features of both classes of algorithms. The proposed scheme utilizes cryptographic hash functions and digital signature schemes and the data does not need to be modified in order to be made authenticatable. Several applications including the authentication of images on CD-ROM and handwritten documents will be discussed.

  6. Digital camera with apparatus for authentication of images produced from an image file

    NASA Technical Reports Server (NTRS)

    Friedman, Gary L. (Inventor)

    1993-01-01

    A digital camera equipped with a processor for authentication of images produced from an image file taken by the digital camera is provided. The digital camera processor has embedded therein a private key unique to it, and the camera housing has a public key that is so uniquely based upon the private key that digital data encrypted with the private key by the processor may be decrypted using the public key. The digital camera processor comprises means for calculating a hash of the image file using a predetermined algorithm, and second means for encrypting the image hash with the private key, thereby producing a digital signature. The image file and the digital signature are stored in suitable recording means so they will be available together. Apparatus for authenticating at any time the image file as being free of any alteration uses the public key for decrypting the digital signature, thereby deriving a secure image hash identical to the image hash produced by the digital camera and used to produce the digital signature. The apparatus calculates from the image file an image hash using the same algorithm as before. By comparing this last image hash with the secure image hash, authenticity of the image file is determined if they match, since even one bit change in the image hash will cause the image hash to be totally different from the secure hash.

  7. Analysis of Gene Expression Profiles of Multiple Skin Diseases Identifies a Conserved Signature of Disrupted Homeostasis.

    PubMed

    Mills, Kevin J; Robinson, Michael K; Sherrill, Joseph D; Schnell, Daniel J; Xu, Jun

    2018-05-28

    Triggers of skin disease pathogenesis vary, but events associated with the elicitation of a lesion share many features in common. Our objective was to examine gene expression patterns in skin disease to develop a molecular signature of disruption of cutaneous homeostasis. Gene expression data from common inflammatory skin diseases (e.g., psoriasis, atopic dermatitis, seborrheic dermatitis and acne), and a novel statistical algorithm were used to define a unifying molecular signature referred to as the "Unhealthy Skin Signature" (USS). Using a pattern matching algorithm, analysis of public data repositories revealed that the USS is found in diverse epithelial diseases. Studies of milder disruptions of epidermal homeostasis have also shown that these conditions converge, to varying degrees, on the USS and that the degree of convergence is related directly to the severity of homeostatic disruption. The USS contains genes that had no prior published association with skin, but that play important roles in many different disease processes, supporting the importance of the USS to homeostasis. Finally, we show through pattern matching that the USS can be used to discover new potential dermatologic therapeutics. The USS provides a new means to further interrogate epithelial homeostasis and potentially develop novel therapeutics with efficacy across a spectrum of skin conditions. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Digital Camera with Apparatus for Authentication of Images Produced from an Image File

    NASA Technical Reports Server (NTRS)

    Friedman, Gary L. (Inventor)

    1996-01-01

    A digital camera equipped with a processor for authentication of images produced from an image file taken by the digital camera is provided. The digital camera processor has embedded therein a private key unique to it, and the camera housing has a public key that is so uniquely related to the private key that digital data encrypted with the private key may be decrypted using the public key. The digital camera processor comprises means for calculating a hash of the image file using a predetermined algorithm, and second means for encrypting the image hash with the private key, thereby producing a digital signature. The image file and the digital signature are stored in suitable recording means so they will be available together. Apparatus for authenticating the image file as being free of any alteration uses the public key for decrypting the digital signature, thereby deriving a secure image hash identical to the image hash produced by the digital camera and used to produce the digital signature. The authenticating apparatus calculates from the image file an image hash using the same algorithm as before. By comparing this last image hash with the secure image hash, authenticity of the image file is determined if they match. Other techniques to address time-honored methods of deception, such as attaching false captions or inducing forced perspectives, are included.

  9. Nonenhanced ECG-gated quiescent-interval single shot MRA: image quality and stenosis assessment at 3 tesla compared with contrast-enhanced MRA and digital subtraction angiography.

    PubMed

    Hansmann, Jan; Morelli, John N; Michaely, Henrik J; Riester, Thomas; Budjan, Johannes; Schoenberg, Stefan O; Attenberger, Ulrike I

    2014-06-01

    To evaluate the diagnostic accuracy of a nonenhanced electrocardiograph-gated quiescent-interval single shot MR-angiography (QISS-MRA) at 3 Tesla with contrast-enhanced MRA (CE-MRA) and digital subtraction angiography (DSA) serving as reference standard. Following institutional review board approval, 16 consecutive patients with peripheral arterial disease underwent a combined peripheral MRA protocol consisting of a large field-of-view QISS-MRA, continuous table movement MRA, and an additional time-resolved MRA of the calves. DSA correlation was available in eight patients. Image quality and degree of stenosis was assessed. Sensitivity and specificity of QISS-MRA was evaluated with CE-MRA and DSA serving as the standards of reference and compared using the Fisher exact test. With the exception of the calf station, image quality with QISS-MRA was rated statistically significantly less than that of CE-MRA (P < 0.05, P = 0.17, and P = 0.6, respectively). A greater percentage of segments were not accessible with QISS-MRA (19.5-20.1%) in comparison to CE-MRA (10.9%). Relative to DSA, sensitivity for QISS-MRA was high (100% versus 91.2% for CE-MRA, P = 0.24) in the evaluated segments; however, specificity (76.5%) was substantially less than that of CE-MRA (94.6%, P = 0.003). Overall image quality and specificity of QISS-MRA at 3T are diminished relative to CE-MRA. However, when image quality is adequate, QISS-MRA has high sensitivity and, thus, has potential use in patients with contraindications to gadolinium. Copyright © 2013 Wiley Periodicals, Inc.

  10. Image Quality and Stenosis Assessment of Non-Contrast-Enhanced 3-T Magnetic Resonance Angiography in Patients with Peripheral Artery Disease Compared with Contrast-Enhanced Magnetic Resonance Angiography and Digital Subtraction Angiography

    PubMed Central

    Liu, Jiayi; Zhang, Nan; Fan, Zhaoyang; Luo, Nan; Zhao, Yike; Bi, Xiaoming; An, Jing; Chen, Zhong; Liu, Dongting; Wen, Zhaoying; Fan, Zhanming; Li, Debiao

    2016-01-01

    Purpose To evaluate the diagnostic performance of flow-sensitive dephasing (FSD)-prepared steady-state free precession (SSFP) magnetic resonance angiography (MRA) at 3 T for imaging infragenual arteries relative to contrast-enhanced MRA (CE-MRA) and digital subtraction angiography (DSA). Materials and Methods A series of 16 consecutive patients with peripheral arterial disease (PAD) underwent a combined peripheral MRA protocol consisting of FSD-MRA for the calves and large field-of-view CE-MRA. DSA was performed on all patients within 1 week of the MR angiographies. Image quality and degree of stenosis was assessed by two readers with rich experience. Inter-observer agreement was determined using kappa statistics. Receiver operating characteristic (ROC) curve analysis determined the diagnostic value of FSD-MRA, CE-MRA, and CE-MRA combined with FSD-MRA (CE+FSD MRA) in predicting vascular stenosis. Results At the calf station, no significantly difference of subjective image quality scores was found between FSD-MRA and CE-MRA. Inter-reader agreement was excellent for both FSD-MRA and CE-MRA. Both of FSD-MRA and CE-MRA carry a stenosis overestimation risk relative to DSA standard. With DSA as the reference standard, ROC curve analysis showed that the area under the curve was largest for CE+FSD MRA. The greatest sensitivity and specificity were obtained when a cut-off stenosis score of 2 was used. Conclusion In patients with severe PAD,3 T FSD-MRA provides good-quality diagnostic images without a contrast agent and is a good supplement for CE-MRA. CE+FSD MRA can improve the accuracy of vascular stenosis diagnosis. PMID:27861626

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schaefer, Philipp J., E-mail: jp.schaefer@rad.uni-kiel.de; Schaefer, Fritz K. W.; Mueller-Huelsbeck, Stefan

    The objective of the study was to prove the value of single-dose contrast-enhanced magnetic resonance angiography [three-dimensional (3D) ceMRA] in abdominal and iliac arteries versus the reference standard intra-arterial digital subtraction angiography (i.a.DSA) when indicating a therapy. Patients suspected of having abdominal or iliac artery stenosis were included in this study. A positive vote of the local Ethics Committee was given. After written informed consent was obtained, 37 patients were enrolled, of which 34 were available for image evaluation. Both 3D ceMRA and i.a. DSA were performed for each patient. The dosage for 3D ceMRA was 0.1 mmol/kg body weightmore » in a 1.5-T scanner with a phased-array coil. The parameters of the 3D-FLASH sequence were as follows: TR/TE 4.6/1.8 ms, effective thickness 3.5 mm, matrix 512 x 200, flip angle 30{sup o}, field of view 420 mm, TA 23 s, coronal scan orientation. Totally, 476 vessel segments were evaluated for stenosis degree by two radiologists in a consensus fashion in a blinded read. For each patient, a therapy was proposed, if clinically indicated. Sensitivity, specificity, positive and negative predictive values, and accuracy for stenoses {>=}50% were 68%, 92%, 44%, 97%, and 90%, respectively. In 13/34 patients, a discrepancy was found concerning therapy decisions based on MRA findings versus therapy decisions based on the reference standard DSA. The results showed that the used MRA imaging technique of abdominal and iliac arteries is not competitive to i.a. DSA, with a high rate of misinterpretation of the MRAs resulting in incorrect therapies.« less

  12. Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy.

    PubMed

    Paul, Jijo; Jacobi, Volkmar; Farhang, Mohammad; Bazrafshan, Babak; Vogl, Thomas J; Mbalisike, Emmanuel C

    2013-06-01

    Radiation dose and image quality estimation of three X-ray volume imaging (XVI) systems. A total of 126 patients were examined using three XVI systems (groups 1-3) and their data were retrospectively analysed from 2007 to 2012. Each group consisted of 42 patients and each patient was examined using cone-beam computed tomography (CBCT), digital subtraction angiography (DSA) and digital fluoroscopy (DF). Dose parameters such as dose-area product (DAP), skin entry dose (SED) and image quality parameters such as Hounsfield unit (HU), noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were estimated and compared using appropriate statistical tests. Mean DAP and SED were lower in recent XVI than its previous counterparts in CBCT, DSA and DF. HU of all measured locations was non-significant between the groups except the hepatic artery. Noise showed significant difference among groups (P < 0.05). Regarding CNR and SNR, the recent XVI showed a higher and significant difference compared to its previous versions. Qualitatively, CBCT showed significance between versions unlike the DSA and DF which showed non-significance. A reduction of radiation dose was obtained for the recent-generation XVI system in CBCT, DSA and DF. Image noise was significantly lower; SNR and CNR were higher than in previous versions. The technological advancements and the reduction in the number of frames led to a significant dose reduction and improved image quality with the recent-generation XVI system. • X-ray volume imaging (XVI) systems are increasingly used for interventional radiological procedures. • More modern XVI systems use lower radiation doses compared with earlier counterparts. • Furthermore more modern XVI systems provide higher image quality. • Technological advances reduce radiation dose and improve image quality.

  13. The Interplay of Socioeconomic Status, Distance to Center, and Interdonor Service Area Travel on Kidney Transplant Access and Outcomes

    PubMed Central

    Axelrod, David A.; Dzebisashvili, Nino; Schnitzler, Mark A.; Salvalaggio, Paolo R.; Segev, Dorry L.; Gentry, Sommer E.; Tuttle-Newhall, Janet

    2010-01-01

    Background and objectives: Variation in kidney transplant access across the United States may motivate relocation of patients with ability to travel to better-supplied areas. Design, setting, participants, & measurements: We examined national transplant registry and U.S. Census data for kidney transplant candidates listed in 1999 to 2009 with a reported residential zip code (n = 203,267). Cox's regression was used to assess associations of socioeconomic status (SES), distance from residence to transplant center, and relocation to a different donation service area (DSA) with transplant access and outcomes. Results: Patients in the highest SES quartile had increased access to transplant compared with those with lowest SES, driven strongly by 76% higher likelihood of living donor transplantation (adjusted hazard ratio [aHR] 1.76, 95% confidence interval [CI] 1.70 to 1.83). Waitlist death was reduced in high compared with low SES candidates (aHR 0.86, 95% CI 0.84 to 0.89). High SES patients also experienced lower mortality after living and deceased donor transplant. Patients living farther from the transplant center had reduced access to deceased donor transplant and increased risk of post-transplant death. Inter-DSA travel was associated with a dramatic increase in deceased donor transplant access (HR 1.94, 95% CI 1.88 to 2.00) and was predicted by high SES, white race, and longer deceased-donor allograft waiting time in initial DSA. Conclusions: Ongoing disparities exist in kidney transplantation access and outcomes on the basis of geography and SES despite near-universal insurance coverage under Medicare. Inter-DSA travel improves access and is more common among high SES candidates. PMID:20798250

  14. Working Memory in Bisphenol-A Treated Middle-Aged Ovariectomized Rats

    PubMed Central

    Neese, Steven L.; Bandara, Suren B.; Schantz, Susan L.

    2014-01-01

    Over 90% of the U.S. population has detectable bisphenol-A (BPA) in their urine according to recent biomonitoring data. BPA is best known for its estrogenic properties, and most rodent research on the nervous system effects of BPA has focused on determining if chronic exposures during pre- and perinatal development have organizational effects on brain development and behavior. Estrogens also have important impacts on brain and behavior during adulthood, particularly in females during aging, but the impact of BPA on the adult brain is less studied. We have published a series of studies documenting that chronic exposure to various estrogens including 17β-estradiol, ERβ selective SERMs and soy phytoestrogens impairs performance of middle-aged female rats on an operant working memory task. The purpose of this study was to determine if chronic oral exposure to BPA would alter working memory on this same task. Ovariectomized (OVX) middle-aged Long Evans rats were tested on an operant delayed spatial alternation (DSA) task. Rats were treated for 8–10 weeks with either a 0 (vehicle control), 5 or 50 μg/kg bw/day oral bolus of BPA. A subset of the vehicle control rats were implanted with a Silastic implant containing 17β-estradiol (low physiological range) to serve as a positive control. All rats were tested for 25 sessions on the DSA task. BPA treatment did not influence performance accuracy on the DSA task, whereas 17β-estradiol significantly impaired performance, as previously reported. The results of this study suggest that chronic oral exposure to BPA does not alter working memory processes of middle-aged OVX rats assessed by this operant DSA task. PMID:23339879

  15. RDS - A systematic approach towards system thermal hydraulics input code development for a comprehensive deterministic safety analysis

    NASA Astrophysics Data System (ADS)

    Salim, Mohd Faiz; Roslan, Ridha; Ibrahim, Mohd Rizal Mamat @

    2014-02-01

    Deterministic Safety Analysis (DSA) is one of the mandatory requirements conducted for Nuclear Power Plant licensing process, with the aim of ensuring safety compliance with relevant regulatory acceptance criteria. DSA is a technique whereby a set of conservative deterministic rules and requirements are applied for the design and operation of facilities or activities. Computer codes are normally used to assist in performing all required analysis under DSA. To ensure a comprehensive analysis, the conduct of DSA should follow a systematic approach. One of the methodologies proposed is the Standardized and Consolidated Reference Experimental (and Calculated) Database (SCRED) developed by University of Pisa. Based on this methodology, the use of Reference Data Set (RDS) as a pre-requisite reference document for developing input nodalization was proposed. This paper shall describe the application of RDS with the purpose of assessing its effectiveness. Two RDS documents were developed for an Integral Test Facility of LOBI-MOD2 and associated Test A1-83. Data and information from various reports and drawings were referred in preparing the RDS. The results showed that by developing RDS, it has made possible to consolidate all relevant information in one single document. This is beneficial as it enables preservation of information, promotes quality assurance, allows traceability, facilitates continuous improvement, promotes solving of contradictions and finally assisting in developing thermal hydraulic input regardless of whichever code selected. However, some disadvantages were also recognized such as the need for experience in making engineering judgments, language barrier in accessing foreign information and limitation of resources. Some possible improvements are suggested to overcome these challenges.

  16. Quantitative Three-Dimensional Characterization of Block Copolymer Directed Self-Assembly on Combined Chemical and Topographical Prepatterned Templates.

    PubMed

    Segal-Peretz, Tamar; Ren, Jiaxing; Xiong, Shisheng; Khaira, Gurdaman; Bowen, Alec; Ocola, Leonidas E; Divan, Ralu; Doxastakis, Manolis; Ferrier, Nicola J; de Pablo, Juan; Nealey, Paul F

    2017-02-28

    Characterization of the three-dimensional (3D) structure in directed self-assembly (DSA) of block copolymers is crucial for understanding the complex relationships between the guiding template and the resulting polymer structure so DSA could be successfully implemented for advanced lithography applications. Here, we combined scanning transmission electron microscopy (STEM) tomography and coarse-grain simulations to probe the 3D structure of P2VP-b-PS-b-P2VP assembled on prepatterned templates using solvent vapor annealing. The templates consisted of nonpreferential background and raised guiding stripes that had PS-preferential top surfaces and P2VP-preferential sidewalls. The full 3D characterization allowed us to quantify the shape of the polymer domains and the interface between domains as a function of depth in the film and template geometry and offered important insights that were not accessible with 2D metrology. Sidewall guiding was advantageous in promoting the alignment and lowering the roughness of the P2VP domains over the sidewalls, but incommensurate confinement from the increased topography could cause roughness and intermittent dislocations in domains over the background region at the bottom of the film. The 3D characterization of bridge structures between domains over the background and breaks within domains on guiding lines sheds light on possible origins of common DSA defects. The positional fluctuations of the PS/P2VP interface between domains showed a depth-dependent behavior, with high levels of fluctuations near both the free surface of the film and the substrate and lower fluctuation levels in the middle of the film. This research demonstrates how 3D characterization offers a better understanding of DSA processes, leading to better design and fabrication of directing templates.

  17. Absence of Activation-induced Cytidine Deaminase, a Regulator of Class Switch Recombination and Hypermutation in B Cells, Suppresses Aorta Allograft Vasculopathy in Mice.

    PubMed

    Nakanishi, Tomonori; Xu, Xiaoyan; Wynn, Carmen; Yamada, Toshiko; Pan, Fan; Erickson, Laurie; Teo, Haeman; Nakagawa, Terry; Masunaga, Taro; Abe, Jumpei; Akamatsu, Masahiko; Tamura, Kouichi; Jiang, Hongsi

    2015-08-01

    Antibody-mediated rejection is caused in part by increasing circulation/production of donor-specific antibody (DSA). Activation-induced cytidine deaminase (AID) is a key regulator of class switch recombination and somatic hypermutation of immunoglobulin in B cells, yet its role in antibody-mediated transplant rejection remains unclear. We show here that AID deficiency in mice enables suppression of allograft vasculopathy (AV) after aorta transplantation, a DSA-mediated process. Splenocytes from C57BL/6 J (B6) AID(−/−) mice were used for determining in vitro proliferation responses, alloreactivity, cell surface marker expression, and antibody production. BALB/c mouse aortas were transplanted into B6 AID(−/−) mice with or without FK506 treatment. Blood and aorta grafts were harvested on day 30 after transplantation and were subjected to DSA, histological, and immunohistological analyses. The AID(−/−) splenocytes were comparable to wild type splenocytes in proliferation responses, alloreactivity, and expression of cell surface markers in vitro. However, they completely failed to produce immunoglobulin G, although they were not impaired in immunoglobulin M production relative to controls. Furthermore, BALB/c aorta grafts from B6 AID(−/−) recipient mice on day 30 after transplantation showed reduced signs of AV compared to the grafts from B6 wild type recipient mice which had severe vascular intimal hyperplasia, interstitial fibrosis, and inflammation. Treatment with FK506 produced a synergistic effect in the grafts from AID(−/−) recipients with further reduction of intimal hyperplasia and fibrosis scores. The AID deficiency inhibits DSA-mediated AV after aorta transplantation in mice. We propose that AID could be a novel molecular target for controlling antibody-mediated rejection in organ transplantation.

  18. Multiparametric MRI of intracranial aneurysms treated with the Woven EndoBridge (WEB): a case of Faraday's cage?

    PubMed

    Nawka, Marie Teresa; Sedlacik, Jan; Frölich, Andreas; Bester, Maxim; Fiehler, Jens; Buhk, Jan-Hendrik

    2018-02-10

    To evaluate multiparametric MRI including non-contrast and contrast-enhanced morphological and angiographic techniques for intracranial aneurysms treated with the single-layer Woven EndoBridge (WEB) embolization system applying simultaneous digital subtraction angiography (DSA) as the reference of standard. We retrospectively identified all patients with incidental and acute ruptured intracranial aneurysms treated with a WEB device (WEB SL and WEB SLS) between March 2014 and June 2016 in our neurovascular center with early (within 7 days) postinterventional multiparametric MRI as well as mid-term (5-8 months) follow-up MRI and DSA available. Occlusion rates were recorded both in DSA and MR angiography (MRA). In MRI, signal intensities within the WEB as well as in the occluded dome distal to the WEB, if present, were measured by region-of-interest (ROI) analysis. Twenty-five patients fulfilled the inclusion criteria. Rates of complete/adequate occlusion at mid-term follow-up were 84% with both MRA and DSA. A strong signal loss within the WEB was observed in all MR sequences at initial and follow-up examinations. ROI analysis did not reveal significant differences in non-contrast (P=0.946) and contrast-enhanced imaging (P=0.377). A T1-hyperintense thrombus in the non-WEB-carrying dome was a frequent observation. Signal intensity measurements in multiparametric MRI suggest that neither contrast-enhanced MRA nor morphological sequences are capable of revealing reliable information on the WEB lumen, presumably due to radio frequency shielding. MRI is therefore not suitable for confirming complete thrombus formation within the WEB. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Quantitative three-dimensional characterization of block copolymer directed self-assembly on combined chemical and topographical prepatterned templates

    DOE PAGES

    Segal-Peretz, Tamar; Ren, Jiaxing; Xiong, Shisheng; ...

    2016-12-22

    Characterization of the three-dimensional (3D) structure in directed self-assembly (DSA) of block copolymers is crucial for understanding the complex relationships between the guiding template and the resulting polymer structure so DSA could be successfully implemented for advanced lithography applications. Here, we combined scanning transmission electron microscopy (STEM) tomography and coarse-grain simulations to probe the 3D structure of P2VP- b-PS- b-P2VP assembled on prepatterned templates using solvent vapor annealing. The templates consisted of nonpreferential background and raised guiding stripes that had PS-preferential top surfaces and P2VP-preferential sidewalls. The full 3D characterization allowed us to quantify the shape of the polymer domainsmore » and the interface between domains as a function of depth in the film and template geometry and offered important insights that were not accessible with 2D metrology. Sidewall guiding was advantageous in promoting the alignment and lowering the roughness of the P2VP domains over the sidewalls, but incommensurate confinement from the increased topography could cause roughness and intermittent dislocations in domains over the background region at the bottom of the film. The 3D characterization of bridge structures between domains over the background and breaks within domains on guiding lines sheds light on possible origins of common DSA defects. The positional fluctuations of the PS/P2VP interface between domains showed a depth-dependent behavior, with high levels of fluctuations near both the free surface of the film and the substrate and lower fluctuation levels in the middle of the film. As a result, this research demonstrates how 3D characterization offers a better understanding of DSA processes, leading to better design and fabrication of directing templates.« less

  20. Evaluating the use and utility of noninvasive angiography in diagnosing traumatic blunt cerebrovascular injury.

    PubMed

    Wang, Anthony C; Charters, Michael A; Thawani, Jayesh P; Than, Khoi D; Sullivan, Stephen E; Graziano, Gregory P

    2012-06-01

    Digital subtraction angiography (DSA) is the gold standard for radiographic diagnosis of blunt cerebrovascular injury (BCVI), but use of computed tomography angiography (CTA) and magnetic resonance angiography (MRA) has increased dramatically in BCVI screening. This study explores the utility, effectiveness, and cost of noninvasive CTA and MRA screening for BCVI. Medical records of 2,025 consecutive adults evaluated for acute blunt neck trauma and BCVI were reviewed retrospectively. The incidence of BCVI, level(s) of cervical injury, involvement of foramina transversaria and internal carotid canals, presence of bony dislocation or subluxation, and subsequent treatment received were assessed. Asymptomatic patients were analyzed based on fracture and injury patterns. The cost effectiveness of CTA compared with DSA and the effects of CTA sensitivity and screening yield were determined. Of reviewed patients, 196 received CTA or MRA. Thirty-eight patients (19.4%) were diagnosed with BCVI. Screening yield in patients symptomatic at presentation was 48.8%. Large-vessel internal carotid, vertebral, anterior spinal, and basilar artery occlusion were associated with a positive screen, as were concurrent stroke and spinal cord injury (p < 0.01). Of patients with injuries found with noninvasive imaging, 50.0% of BCVI involved C1-3 fracture, 34.2% involved subluxation, and 65.8% involved foramina transversaria. In both symptomatic and asymptomatic patients, CTA screening was more cost effective than DSA. Noninvasive imaging is a safe, accurate, and cost-effective tool for BCVI screening. Symptomatic presentation was the best predictor of BCVI. Significant cost savings were realized using CTA rather than DSA, with similar effectiveness and patient outcomes. Diagnostic study, level III; economic analysis, level IV. Copyright © 2012 by Lippincott Williams & Wilkins

  1. Directed Self-Assembly of Polystyrene- b -poly(propylene carbonate) on Chemical Patterns via Thermal Annealing for Next Generation Lithography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Guan-Wen; Wu, Guang-Peng; Chen, Xuanxuan

    2017-01-23

    Directed self-assembly (DSA) of block copolymers (BCPs) combines advantages of conventional photolithography and polymeric materials and shows competence in semiconductors and data storage applications. Driven by the more integrated, much smaller and higher performance of the electronics, however, the industry standard polystyrene-block-poly(methyl methacrylate) (PS-b-PMM.A) in DSA strategy cannot meet the rapid development of lithography technology because its intrinsic limited Flory-Huggins interaction parameter (chi). Despite hundreds of block copolymers have been developed, these BCPs systems are usually subject to a trade-off between high chi and thermal treatment, resulting in incompatibility with the current nanomanufacturing fab processes. Here we discover that polystyrene-b-poly(propylenemore » carbonate) (PS-b-PPC) is well qualified to fill key positions on DSA strategy for the next-generation lithography. The estimated chi-value for PS-b-PPC is 0.079, that is, two times greater than PS-b-PMMA (chi = 0.029 at 150 degrees C), while processing the ability to form perpendicular sub-10 nm morphologies (cylinder and lamellae) via the industry preferred thermal-treatment. DSA of lamellae forming PS-b-PPC on chemoepitaxial density multiplication demonstrates successful sub-10 nm long-range order features on large-area patterning for nanofabrication. Pattern transfer to the silicon substrate through industrial sequential infiltration synthesis is also implemented successfully. Compared with the previously reported methods to orientation control BCPs with high chi-value (including solvent annealing, neutral top-coats, and chemical modification), the easy preparation, high chi value, and etch selectivity while enduring thermal treatment demonstrates PS-b-PPC as a rare and valuable candidate for advancing the field of nanolithography.« less

  2. Interobserver Agreement on Arteriovenous Malformation Diffuseness Using Digital Subtraction Angiography.

    PubMed

    Braileanu, Maria; Yang, Wuyang; Caplan, Justin M; Lin, Li-Mei; Radvany, Martin G; Tamargo, Rafael J; Huang, Judy

    2016-11-01

    Arteriovenous malformation (AVM) diffuseness has been shown to be prognostic of treatment outcomes. We assessed interobserver agreement of AVM diffuseness among physicians of different specialty and training backgrounds using digital subtraction angiography (DSA). All research protocols were approved by the institutional review board for this retrospective chart review. In a single-blinded setting, 2 attending neurosurgeons, 1 attending interventional neuroradiologist, and 1 senior neurosurgical resident rated 80 DSA views of 36 AVMs as either compact or diffuse. Individual interobserver agreement and subgroup agreement were analyzed using κ agreement and intraclass correlation coefficient. Disagreement regarding AVM diffuseness occurred in 43.8% of all DSA views (n = 80). Interobserver κ agreement on AVM diffuseness using DSA views among 4 physicians ranged from fair (κ = 0.40 [95% confidence interval (CI) = 0.22-0.58]) to substantial (κ = 0.65 [95% CI = 0.48-0.81]), whereas total intraclass correlation coefficient was 0.81 (95% CI = 0.73-0.87). For the 36 AVMs, κ agreement ranged from fair (κ = 0.36 [95% CI = 0.13-0.60]) to moderate (κ = 0.57 [95% CI = 0.35-0.79]), whereas intraclass correlation coefficient among all 4 physicians was 0.68 (95% CI = 0.47-0.82). Moderate agreement on AVM diffuseness (n = 80) was found between attending and resident assessments (κ = 0.57 [95% CI = 0.39-0.75]) and between neurosurgeon and interventional neuroradiologist assessments (κ = 0.55 [95% CI = 0.37-0.73]). Agreement of individual physicians on AVM diffuseness varies from fair to substantial. Objective and three-dimensional measures of AVM diffuseness should be developed for consistent clinical application. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Multi-species first-principles simulations of particle acceleration at shocks

    NASA Astrophysics Data System (ADS)

    Caprioli, Damiano

    Astrophysical shocks are known to be prominent sources of non-thermal particles and emission. In particular, strong shocks at supernova remnant blast waves are thought to accelerate Galactic cosmic rays (CRs) up to about 10^17eV via diffusive shock acceleration (DSA). The chemical composition of Galactic CRs, now measured with great accuracy by payloads and satellites, is reminiscent of that of the typical interstellar medium, although with some significant deviations. Observations reveal: 1) an electron/proton ratio of about 1% at about 10 GeV, (2) a general enhancement of the refractory elements relative to the volatile ones, (3) among the volatile elements, an enhancement of the heavier elements relative to the lighter ones, and (4) a discrepant hardening of CR nuclei heavier than hydrogen. Such peculiar trends contain precious information about the dependence of the acceleration process on the particle mass/charge ratio, a trend that has no theoretical counterpart in the DSA theory, yet. Building on our recent successes in modeling electron and proton DSA at non-relativistic astrophysical shocks via first-principles kinetic simulations, we will perform multispecies particle-in-cells simulations of such systems also including nuclei heavier than hydrogen, in order to investigate thermalization, injection, and acceleration of species with different mass/charge ratio. We will also analyze how the simulation outputs compare with the observed CR abundances, in order to build a model for DSA that accounts for the relative acceleration efficiency of energetic electrons, protons, and heavier ions. Finally, we will assess the possible contribution of accelerated heavy ions, especially helium, to the generation of magnetic turbulence via CR-driven instabilities - crucial to foster rapid particle energgization- and to the hadronic gamma-ray emission from young supernova remnants.

  4. CT angiography for one-year follow-up of intracranial aneurysms treated with the WEB device: Utility in evaluating aneurysm occlusion and WEB compression at one year.

    PubMed

    Raoult, Hélène; Eugène, François; Le Bras, Anthony; Mineur, Géraldine; Carsin-Nicol, Béatrice; Ferré, Jean-Christophe; Gauvrit, Jean-Yves

    2018-03-07

    The WEB is an innovative flow disruption device for cerebral aneurysm embolization with rapidly expanding indications. Our purpose was to evaluate the diagnostic performance of computed tomography angiography (CTA) at 1-year follow-up of aneurysms treated with the WEB. Between April 2014 and May 2016, the study prospectively included patients treated with the WEB at our institution, and followed up within 24hours by CTA and at 1year by CTA, time-of-flight magnetic resonance angiography (TOF MRA) and digital subtraction angiography (DSA). The diagnostic quality of imaging data was assessed based on the confidence index, artifacts, and WEB shape depiction. The imaging diagnostic performance was assessed using 3 criteria at 1year: aneurysm occlusion status and worsening, and WEB shape compression. Interobserver and intermodality agreement was determined by calculating κ values. The study ultimately included 16 patients (9 women, mean age 53±7.6years). CTA quality confidence was scored as 2/2, artifacts 0.4/2 and WEB shape depiction 1.9/2, superior to TOF MRA for the latter two criteria. Aneurysm occlusion was adequate in 93.7% of patients, with CTA showing excellent interobserver reproducibility and agreement with DSA on a 4-grade scale (κ=1.00), while TOF MRA yielded good reproducibility (κ=0.76) and agreement with DSA (κ=0.69). CTA also identified aneurysm occlusion worsening (43.7%) and WEB compression (81.2%) in excellent agreement with DSA (κ=0.85 and 1.00). CTA is a reproducible and reliable technique for the follow-up of aneurysms treated with the WEB device. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  5. Magnetic resonance angiography in infrapopliteal arterial disease: prospective comparison of 1.5 and 3 Tesla magnetic resonance imaging.

    PubMed

    Diehm, Nicolas; Kickuth, Ralph; Baumgartner, Iris; Srivastav, Sudesh K; Gretener, Silvia; Husmann, Marc J; Jaccard, Yves; Do, Do Dai; Triller, Juergen; Bonel, Harald M

    2007-06-01

    To prospectively determine the accuracy of 1.5 Tesla (T) and 3 T magnetic resonance angiography (MRA) versus digital subtraction angiography (DSA) in the depiction of infrageniculate arteries in patients with symptomatic peripheral arterial disease. A prospective 1.5 T, 3 T MRA, and DSA comparison was used to evaluate 360 vessel segments in 10 patients (15 limbs) with chronic symptomatic peripheral arterial disease. Selective DSA was performed within 30 days before both MRAs. The accuracy of 1.5 T and 3 T MRA was compared with DSA as the standard of reference by consensus agreement of 2 experienced readers. Signal-to-noise ratios (SNR) and signal-difference-to-noise ratios (SDNRs) were quantified. No significant difference in overall image quality, sufficiency for diagnosis, depiction of arterial anatomy, motion artifacts, and venous overlap was found comparing 1.5 T with 3 T MRA (P > 0.05 by Wilcoxon signed rank and as by Cohen k test). Overall sensitivity of 1.5 and 3 T MRA for detection of significant arterial stenosis was 79% and 82%, and specificity was 87% and 87% for both modalities, respectively. Interobserver agreement was excellent k > 0.8, P < 0.05) for 1.5 T as well as for 3 T MRA. SNR and SDNR were significantly increased using the 3 T system (average increase: 36.5%, P < 0.032 by t test, and 38.5%, P < 0.037 respectively). Despite marked improvement of SDNR, 3 T MRA does not yet provide a significantly higher accuracy in diagnostic imaging of atherosclerotic lesions below the knee joint as compared with 1.5 T MRA.

  6. The Spectrum of Renal Allograft Failure

    PubMed Central

    Chand, Sourabh; Atkinson, David; Collins, Clare; Briggs, David; Ball, Simon; Sharif, Adnan; Skordilis, Kassiani; Vydianath, Bindu; Neil, Desley; Borrows, Richard

    2016-01-01

    Background Causes of “true” late kidney allograft failure remain unclear as study selection bias and limited follow-up risk incomplete representation of the spectrum. Methods We evaluated all unselected graft failures from 2008–2014 (n = 171; 0–36 years post-transplantation) by contemporary classification of indication biopsies “proximate” to failure, DSA assessment, clinical and biochemical data. Results The spectrum of graft failure changed markedly depending on the timing of allograft failure. Failures within the first year were most commonly attributed to technical failure, acute rejection (with T-cell mediated rejection [TCMR] dominating antibody-mediated rejection [ABMR]). Failures beyond a year were increasingly dominated by ABMR and ‘interstitial fibrosis with tubular atrophy’ without rejection, infection or recurrent disease (“IFTA”). Cases of IFTA associated with inflammation in non-scarred areas (compared with no inflammation or inflammation solely within scarred regions) were more commonly associated with episodes of prior rejection, late rejection and nonadherence, pointing to an alloimmune aetiology. Nonadherence and late rejection were common in ABMR and TCMR, particularly Acute Active ABMR. Acute Active ABMR and nonadherence were associated with younger age, faster functional decline, and less hyalinosis on biopsy. Chronic and Chronic Active ABMR were more commonly associated with Class II DSA. C1q-binding DSA, detected in 33% of ABMR episodes, were associated with shorter time to graft failure. Most non-biopsied patients were DSA-negative (16/21; 76.1%). Finally, twelve losses to recurrent disease were seen (16%). Conclusion This data from an unselected population identifies IFTA alongside ABMR as a very important cause of true late graft failure, with nonadherence-associated TCMR as a phenomenon in some patients. It highlights clinical and immunological characteristics of ABMR subgroups, and should inform clinical practice and individualised patient care. PMID:27649571

  7. Treatment of chronic antibody mediated rejection with intravenous immunoglobulins and rituximab: A multicenter, prospective, randomized, double-blind clinical trial.

    PubMed

    Moreso, Francesc; Crespo, Marta; Ruiz, Juan C; Torres, Armando; Gutierrez-Dalmau, Alex; Osuna, Antonio; Perelló, Manel; Pascual, Julio; Torres, Irina B; Redondo-Pachón, Dolores; Rodrigo, Emilio; Lopez-Hoyos, Marcos; Seron, Daniel

    2018-04-01

    There are no approved treatments for chronic antibody mediated rejection (ABMR). We conducted a multicenter, prospective, randomized, placebo-controlled, double-blind clinical trial to evaluate efficacy and safety of intravenous immunoglobulins (IVIG) combined with rituximab (RTX) (EudraCT 2010-023746-67). Patients with transplant glomerulopathy and anti-HLA donor-specific antibodies (DSA) were eligible. Patients with estimated glomerular filtration rate (eGFR) <20 mL/min per 1.73m 2 and/or severe interstitial fibrosis/tubular atrophy were excluded. Patients were randomized to receive IVIG (4 doses of 0.5 g/kg) and RTX (375 mg/m 2 ) or a wrapped isovolumetric saline infusion. Primary efficacy variable was the decline of eGFR at one year. Secondary efficacy variables included evolution of proteinuria, renal lesions, and DSA at 1 year. The planned sample size was 25 patients per group. During 2012-2015, 25 patients were randomized (13 to the treatment and 12 to the placebo group). The planned patient enrollment was not achieved because of budgetary constraints and slow patient recruitment. There were no differences between the treatment and placebo groups in eGFR decline (-4.2 ± 14.4 vs. -6.6 ± 12.0 mL/min per 1.73 m 2 , P-value = .475), increase of proteinuria (+0.9 ± 2.1 vs. +0.9 ± 2.1 g/day, P-value = .378), Banff scores at one year and MFI of the immunodominant DSA. Safety was similar between groups. These data suggest that the combination of IVIG and RTX is not useful in patients displaying transplant glomerulopathy and DSA. © 2017 The American Society of Transplantation and the American Society of Transplant Surgeons.

  8. Working memory in bisphenol-A treated middle-aged ovariectomized rats.

    PubMed

    Neese, Steven L; Bandara, Suren B; Schantz, Susan L

    2013-01-01

    Over 90% of the U.S. population has detectable bisphenol-A (BPA) in their urine according to recent biomonitoring data. BPA is best known for its estrogenic properties, and most rodent research on the nervous system effects of BPA has focused on determining if chronic exposures during pre- and perinatal development have organizational effects on brain development and behavior. Estrogens also have important impacts on brain and behavior during adulthood, particularly in females during aging, but the impact of BPA on the adult brain is less studied. We have published a series of studies documenting that chronic exposure to various estrogens including 17β-estradiol, ERβ selective SERMs and soy phytoestrogens impairs performance of middle-aged female rats on an operant working memory task. The purpose of this study was to determine if chronic oral exposure to BPA would alter working memory on this same task. Ovariectomized (OVX) middle-aged Long Evans rats were tested on an operant delayed spatial alternation (DSA) task. Rats were treated for 8-10 weeks with either a 0 (vehicle control), 5 or 50 μg/kg bw/day oral bolus of BPA. A subset of the vehicle control rats was implanted with a Silastic implant containing 17β-estradiol (low physiological range) to serve as a positive control. All rats were tested for 25 sessions on the DSA task. BPA treatment did not influence performance accuracy on the DSA task, whereas 17β-estradiol significantly impaired performance, as previously reported. The results of this study suggest that chronic oral exposure to BPA does not alter working memory processes of middle-aged OVX rats assessed by this operant DSA task. Copyright © 2013. Published by Elsevier Inc.

  9. Lower limb vascular disease in diabetic patients: a study with calf compression contrast-enhanced magnetic resonance angiography at 3.0 Tesla.

    PubMed

    Li, Jie; Zhao, Jun-Gong; Li, Ming-Hua

    2011-06-01

    To retrospectively analyze the significance of 3.0-T contrast-enhanced (CE) magnetic resonance angiography (MRA) with calf compression in the lower limbs of diabetic patients with peripheral vascular disease. Sixty-one type 2 diabetes patients underwent both MRA and digital subtraction angiography (DSA) within 1 week. The patients were divided into two groups: one with (pressure) and one without (conventional) calf compression during MRA. Two radiologists evaluated the quality of MRA images and compared the two groups. Cohen's kappa statistic was used to determine the concordance between MRA and DSA. Image quality in the calf and foot was better in the group with calf pressure than the conventional group without applied pressure (P = .001 [calf], 0.008 [foot]). Significantly more runoff vessels in the calf were detected with MRA than with DSA (P = .0043 [conventional], 0.0031 [pressure]). The kappa values were 0.928 in the conventional group and 0.979 in the pressure group, but in the conventional group, the diagnostic accuracy of CE-MRA was lower than that of DSA (P = .002). Diagnostic accuracy in the pressure group was significantly higher than that in the conventional group (P = .009). The overall sensitivity and specificity for >50% stenosis or occlusion was 93.8% and 98.5%, respectively, in the conventional group and 98.7% and 99.6%, respectively, in the pressure group. With calf compression, venous overlap (P = .0396, .0425) and deep vein overlap (P = .022, .022) were significantly reduced in the leg and foot. Calf compression with 3.0-T CE-MRA was convenient and practical and could improve image quality and diagnostic accuracy in diabetic patients with peripheral vascular disease by reducing venous overlap. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  10. Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography.

    PubMed

    Huang, Xingfu; Chen, Yanjia; Huang, Zheng; He, Liwei; Liu, Shenrong; Deng, Xiaojiang; Wang, Yongsheng; Li, Rucheng; Xu, Dingli; Peng, Jian

    2018-06-01

    Several studies have reported the efficacy of a zero-fluoroscopy approach for catheter radiofrequency ablation of arrhythmias in a digital subtraction angiography (DSA) room. However, no reports are available on the ablation of arrhythmias in the absence of DSA in the operating room. To investigate the efficacy and safety of catheter radiofrequency ablation for arrhythmias under the guidance of a Carto 3 three-dimensional (3D) mapping system in an operating room without DSA. Patients were enrolled according to the type of arrhythmia. The Carto 3 mapping system was used to reconstruct heart models and guide the electrophysiologic examination, mapping, and ablation. The total procedure, reconstruction, electrophysiologic examination, and mapping times were recorded. Furthermore, immediate success rates and complications were also recorded. A total of 20 patients were enrolled, including 12 males. The average age was 51.3 ± 17.2 (19-76) years. Nine cases of atrioventricular nodal re-entrant tachycardia, 7 cases of frequent ventricular premature contractions, 3 cases of Wolff-Parkinson-White syndrome, and 1 case of typical atrial flutter were included. All arrhythmias were successfully ablated. The procedure time was 127.0 ± 21.0 (99-177) minutes, the reconstruction time was 6.5 ± 2.9 (3-14) minutes, the electrophysiologic study time was 10.4 ± 3.4 (6-20) minutes, and the mapping time was 11.7 ± 8.3 (3-36) minutes. No complications occurred. Radiofrequency ablation of arrhythmias without DSA is effective and feasible under the guidance of the Carto 3 mapping system. However, the electrophysiology physician must have sufficient experience, and related emergency measures must be present to ensure safety.

  11. Complement-binding anti-HLA antibodies are independent predictors of response to treatment in kidney recipients with antibody-mediated rejection.

    PubMed

    Viglietti, Denis; Bouatou, Yassine; Kheav, Vissal David; Aubert, Olivier; Suberbielle-Boissel, Caroline; Glotz, Denis; Legendre, Christophe; Taupin, Jean-Luc; Zeevi, Adriana; Loupy, Alexandre; Lefaucheur, Carmen

    2018-05-22

    A major hurdle to improving clinical care in the field of kidney transplantation is the lack of biomarkers of the response to antibody-mediated rejection (ABMR) treatment. To discover these we investigated the value of complement-binding donor-specific anti-HLA antibodies (DSAs) for evaluating the response to treatment. The study encompassed a prospective cohort of 139 kidney recipients with ABMR receiving the standard of care treatment, including plasma exchange, intravenous immunoglobulin and rituximab. Patients were systematically assessed at the time of diagnosis and three months after treatment initiation for clinical and allograft histological characteristics and anti-HLA DSAs, including their C1q-binding ability. After adjusting for clinical and histological parameters, post-treatment C1q-binding anti-HLA DSA was an independent and significant determinant of allograft loss (adjusted hazard ratio 2.57 (95% confidence interval 1.29-5.12). In 101 patients without post-treatment C1q-binding anti-HLA DSA there was a significantly improved glomerular filtration rate with significantly reduced glomerulitis, peritubular capillaritis, interstitial inflammation, tubulitis, C4d deposition, and endarteritis compared with 38 patients with posttreatment C1q-binding anti-HLA DSA. A conditional inference tree model identified five prognostic groups at the time of post-treatment evaluation based on glomerular filtration rate, presence of cg lesion and C1q-binding anti-HLA DSA (cross-validated accuracy: 0.77). Thus, circulating complement-binding anti-HLA DSAs are strong and independent predictors of allograft outcome after standard of care treatment in kidney recipients with ABMR. Copyright © 2018 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  12. Contrast material-enhanced, moving-table MR angiography versus digital subtraction angiography for surveillance of peripheral arterial bypass grafts.

    PubMed

    Loewe, Christian; Cejna, Manfred; Schoder, Maria; Loewe-Grgurin, Maria; Wolf, Florian; Lammer, Johannes; Thurnher, Siegfried A

    2003-09-01

    To assess the accuracy of moving-table MR angiography (MRA) in the evaluation of peripheral bypass grafts. There were 39 patients who had had peripheral bypass graft surgery and then subsequently underwent digital subtraction angiography (DSA) and contrast material-enhanced MRA, which was performed with moving-table software on a 1.0-T system before and during administration of 40 mL gadolinium. For evaluation, every bypass graft was divided into three parts and every leg into 14 segments. Disease severity was scored in four categories (0%-29%, 30%-69%, 70%-99%, 100%). Results were compared with those of the DSA. A total of 147 bypass graft segments and 938 vessel segments were classified. In 132 of the assessable 147 bypass segments, disease gradings with both methods were congruent; however, 13 stenoses were misinterpreted by MRA for one grade and two additional lesions by two grades, leading to an accuracy in precise stenoses detection of 89.9%. The sensitivity and specificity values in the detection of bypass graft stenoses >69% (grade 3 + 4 lesions) reached 90.0% and 98.3%, respectively. In 821 of 938 vessel segments the accuracy of MRA in stenoses detection reached 87.5%. The sensitivity and specificity values in the detection of grade 3 + 4 lesions were 95.6% and 94.0% for the native vessels, respectively. Moving-table MRA was as accurate in assessing bypass grafts as it was for the native arteries and showed a great accuracy in stenosis detection compared with DSA. Therefore, MRA is a promising modality for bypass graft surveillance and might be a noninvasive alternative to DSA in this regard.

  13. Post interaural neural net-based vowel recognition

    NASA Astrophysics Data System (ADS)

    Jouny, Ismail I.

    2001-10-01

    Interaural head related transfer functions are used to process speech signatures prior to neural net based recognition. Data representing the head related transfer function of a dummy has been collected at MIT and made available on the Internet. This data is used to pre-process vowel signatures to mimic the effects of human ear on speech perception. Signatures representing various vowels of the English language are then presented to a multi-layer perceptron trained using the back propagation algorithm for recognition purposes. The focus in this paper is to assess the effects of human interaural system on vowel recognition performance particularly when using a classification system that mimics the human brain such as a neural net.

  14. Design of a mutual authentication based on NTRUsign with a perturbation and inherent multipoint control protocol frames in an Ethernet-based passive optical network

    NASA Astrophysics Data System (ADS)

    Yin, Aihan; Ding, Yisheng

    2014-11-01

    Identity-related security issues inherently present in passive optical networks (PON) still exist in the current (1G) and next-generation (10G) Ethernet-based passive optical network (EPON) systems. We propose a mutual authentication scheme that integrates an NTRUsign digital signature algorithm with inherent multipoint control protocol (MPCP) frames over an EPON system between the optical line terminal (OLT) and optical network unit (ONU). Here, a primitive NTRUsign algorithm is significantly modified through the use of a new perturbation so that it can be effectively used for simultaneously completing signature and authentication functions on the OLT and the ONU sides. Also, in order to transmit their individual sensitive messages, which include public key, signature, and random value and so forth, to each other, we redefine three unique frames according to MPCP format frame. These generated messages can be added into the frames and delivered to each other, allowing the OLT and the ONU to go ahead with a mutual identity authentication process to verify their legal identities. Our simulation results show that this proposed scheme performs very well in resisting security attacks and has low influence on the registration efficiency to to-be-registered ONUs. A performance comparison with traditional authentication algorithms is also presented. To the best of our knowledge, no detailed design of mutual authentication in EPON can be found in the literature up to now.

  15. Generation of signature databases with fast codes

    NASA Astrophysics Data System (ADS)

    Bradford, Robert A.; Woodling, Arthur E.; Brazzell, James S.

    1990-09-01

    Using the FASTSIG signature code to generate optical signature databases for the Ground-based Surveillance and Traking System (GSTS) Program has improved the efficiency of the database generation process. The goal of the current GSTS database is to provide standardized, threat representative target signatures that can easily be used for acquisition and trk studies, discrimination algorithm development, and system simulations. Large databases, with as many as eight interpolalion parameters, are required to maintain the fidelity demands of discrimination and to generalize their application to other strateg systems. As the need increases for quick availability of long wave infrared (LWIR) target signatures for an evolving design4o-threat, FASTSIG has become a database generation alternative to using the industry standard OptiCal Signatures Code (OSC). FASTSIG, developed in 1985 to meet the unique strategic systems demands imposed by the discrimination function, has the significant advantage of being a faster running signature code than the OSC, typically requiring two percent of the cpu time. It uses analytical approximations to model axisymmetric targets, with the fidelity required for discrimination analysis. Access of the signature database is accomplished through use of the waveband integration and interpolation software, INTEG and SIGNAT. This paper gives details of this procedure as well as sample interpolated signatures and also covers sample verification by comparison to the OSC, in order to establish the fidelity of the FASTSIG generated database.

  16. Free-Piston Shock Tunnel Test Technique Development: An AEDC/DLR Cooperative Program

    DTIC Science & Technology

    2003-02-01

    Calibration Data." AIAA-95-6039, April 1995. 15. Molvik, G. A., and Merkle , C. L. "A Set of Strongly Coupled, Upwind Algorithms for Com- puting Flows in...April 1997. h. Date of Termination: 28 April 2002. i. All Signing Officials, Title/Offices Represented, and Countries: (1) Herr Rolf Schreiber, Chief...agreement by the RTP MOU Executive Agents. The US RTP/EA Signature Signature Clinton V. Hom, Maj Gen. USAF Rolf Schreiber Name Name Principal Assistant

  17. Isobaric Reconstruction of the Baryonic Acoustic Oscillation

    NASA Astrophysics Data System (ADS)

    Wang, Xin; Yu, Hao-Ran; Zhu, Hong-Ming; Yu, Yu; Pan, Qiaoyin; Pen, Ue-Li

    2017-06-01

    In this Letter, we report a significant recovery of the linear baryonic acoustic oscillation (BAO) signature by applying the isobaric reconstruction algorithm to the nonlinear matter density field. Assuming only the longitudinal component of the displacement being cosmologically relevant, this algorithm iteratively solves the coordinate transform between the Lagrangian and Eulerian frames without requiring any specific knowledge of the dynamics. For dark matter field, it produces the nonlinear displacement potential with very high fidelity. The reconstruction error at the pixel level is within a few percent and is caused only by the emergence of the transverse component after the shell-crossing. As it circumvents the strongest nonlinearity of the density evolution, the reconstructed field is well described by linear theory and immune from the bulk-flow smearing of the BAO signature. Therefore, this algorithm could significantly improve the measurement accuracy of the sound horizon scale s. For a perfect large-scale structure survey at redshift zero without Poisson or instrumental noise, the fractional error {{Δ }}s/s is reduced by a factor of ˜2.7, very close to the ideal limit with the linear power spectrum and Gaussian covariance matrix.

  18. Distributed Unmixing of Hyperspectral Datawith Sparsity Constraint

    NASA Astrophysics Data System (ADS)

    Khoshsokhan, S.; Rajabi, R.; Zayyani, H.

    2017-09-01

    Spectral unmixing (SU) is a data processing problem in hyperspectral remote sensing. The significant challenge in the SU problem is how to identify endmembers and their weights, accurately. For estimation of signature and fractional abundance matrices in a blind problem, nonnegative matrix factorization (NMF) and its developments are used widely in the SU problem. One of the constraints which was added to NMF is sparsity constraint that was regularized by L1/2 norm. In this paper, a new algorithm based on distributed optimization has been used for spectral unmixing. In the proposed algorithm, a network including single-node clusters has been employed. Each pixel in hyperspectral images considered as a node in this network. The distributed unmixing with sparsity constraint has been optimized with diffusion LMS strategy, and then the update equations for fractional abundance and signature matrices are obtained. Simulation results based on defined performance metrics, illustrate advantage of the proposed algorithm in spectral unmixing of hyperspectral data compared with other methods. The results show that the AAD and SAD of the proposed approach are improved respectively about 6 and 27 percent toward distributed unmixing in SNR=25dB.

  19. Renyi entanglement entropy of interacting fermions calculated using the continuous-time quantum Monte Carlo method.

    PubMed

    Wang, Lei; Troyer, Matthias

    2014-09-12

    We present a new algorithm for calculating the Renyi entanglement entropy of interacting fermions using the continuous-time quantum Monte Carlo method. The algorithm only samples the interaction correction of the entanglement entropy, which by design ensures the efficient calculation of weakly interacting systems. Combined with Monte Carlo reweighting, the algorithm also performs well for systems with strong interactions. We demonstrate the potential of this method by studying the quantum entanglement signatures of the charge-density-wave transition of interacting fermions on a square lattice.

  20. Correlation signatures of wet soils and snows. [algorithm development and computer programming

    NASA Technical Reports Server (NTRS)

    Phillips, M. R.

    1972-01-01

    Interpretation, analysis, and development of algorithms have provided the necessary computational programming tools for soil data processing, data handling and analysis. Algorithms that have been developed thus far, are adequate and have been proven successful for several preliminary and fundamental applications such as software interfacing capabilities, probability distributions, grey level print plotting, contour plotting, isometric data displays, joint probability distributions, boundary mapping, channel registration and ground scene classification. A description of an Earth Resources Flight Data Processor, (ERFDP), which handles and processes earth resources data under a users control is provided.

  1. Secure Obfuscation for Encrypted Group Signatures

    PubMed Central

    Fan, Hongfei; Liu, Qin

    2015-01-01

    In recent years, group signature techniques are widely used in constructing privacy-preserving security schemes for various information systems. However, conventional techniques keep the schemes secure only in normal black-box attack contexts. In other words, these schemes suppose that (the implementation of) the group signature generation algorithm is running in a platform that is perfectly protected from various intrusions and attacks. As a complementary to existing studies, how to generate group signatures securely in a more austere security context, such as a white-box attack context, is studied in this paper. We use obfuscation as an approach to acquire a higher level of security. Concretely, we introduce a special group signature functionality-an encrypted group signature, and then provide an obfuscator for the proposed functionality. A series of new security notions for both the functionality and its obfuscator has been introduced. The most important one is the average-case secure virtual black-box property w.r.t. dependent oracles and restricted dependent oracles which captures the requirement of protecting the output of the proposed obfuscator against collision attacks from group members. The security notions fit for many other specialized obfuscators, such as obfuscators for identity-based signatures, threshold signatures and key-insulated signatures. Finally, the correctness and security of the proposed obfuscator have been proven. Thereby, the obfuscated encrypted group signature functionality can be applied to variants of privacy-preserving security schemes and enhance the security level of these schemes. PMID:26167686

  2. Latest evolution in a 300mm graphoepitaxy pilot line flow for L/S applications

    NASA Astrophysics Data System (ADS)

    Claveau, G.; Argoud, M.; Pimenta-Barros, P.; Chamiot-Maitral, G.; Tiron, R.; Chevalier, X.; Navarro, C.

    2017-03-01

    Directed Self Assembly (DSA) of block-copolymers (BCPs) used as a complementary technique to the 193nm immersion lithography has demonstrated sub-10nm node applications in both via and line/space patterning. We propose however to study the performance of graphoepitaxy which allows DSA with thicker initial BCP layer, higher multiplication factors and stronger orientation control of lamellae. The aim of this work is to use the 300mm pilot line available at LETI and Arkema's advanced materials to evaluate the performances of a novel graphoepitaxy process based on the work on a 38nm period lamellar PS-b-PMMA (L38) reported before.

  3. First-Pass Contrast-Enhanced MRA for Pretherapeutic Diagnosis of Spinal Epidural Arteriovenous Fistulas with Intradural Venous Reflux.

    PubMed

    Mathur, S; Symons, S P; Huynh, T J; Muthusami, P; Montanera, W; Bharatha, A

    2017-01-01

    Spinal epidural AVFs are rare spinal vascular malformations. When there is associated intradural venous reflux, they may mimic the more common spinal dural AVFs. Correct diagnosis and localization before conventional angiography is beneficial to facilitate treatment. We hypothesize that first-pass contrast-enhanced MRA can diagnose and localize spinal epidural AVFs with intradural venous reflux and distinguish them from other spinal AVFs. Forty-two consecutive patients with a clinical and/or radiologic suspicion of spinal AVF underwent MR imaging, first-pass contrast-enhanced MRA, and DSA at a single institute (2000-2015). MR imaging/MRA and DSA studies were reviewed by 2 independent blinded observers. DSA was used as the reference standard. On MRA, all 7 spinal epidural AVFs with intradural venous reflux were correctly diagnosed and localized with no interobserver disagreement. The key diagnostic feature was arterialized filling of an epidural venous pouch with a refluxing radicular vein arising from the arterialized epidural venous system. First-pass contrast-enhanced MRA is a reliable and useful technique for the initial diagnosis and localization of spinal epidural AVFs with intradural venous reflux and can distinguish these lesions from other spinal AVFs. © 2017 by American Journal of Neuroradiology.

  4. Experimental measurements on transverse vibration characteristics of piezoceramic rectangular plates by optical methods

    NASA Astrophysics Data System (ADS)

    Ma, Chien-Ching; Lin, Hsien-Yang

    2005-09-01

    This study provides two non-contact optical techniques to investigate the transverse vibration characteristics of piezoceramic rectangular plates in resonance. These methods, including the amplitude-fluctuation electronic speckle pattern interferometry (AF-ESPI) and laser Doppler vibrometer (LDV), are full-field measurement for AF-ESPI and point-wise displacement measurement for LDV, respectively. The edges of these piezoceramic rectangular plates may either be fixed or free. Both resonant frequencies and mode shapes of vibrating piezoceramic plates can be obtained simultaneously by AF-ESPI. Excellent quality of the interferometric fringe patterns for the mode shapes is obtained. In the LDV system, a built-in dynamic signal analyzer (DSA) composed of DSA software and a plug-in waveform generator board can provide the piezoceramic plates with the swept-sine excitation signal, whose gain at corresponding frequencies is analyzed by the DSA software. The peaks appeared in the frequency response curve are resonant frequencies. In addition to these optical methods, the numerical computation based on the finite element analysis is used to verify the experimental results. Good agreements of the mode shapes and resonant frequencies are obtained for experimental and numerical results.

  5. Contribution to aroma characteristics of mutton process flavor from the enzymatic hydrolysate of sheep bone protein assessed by descriptive sensory analysis and gas chromatography olfactometry.

    PubMed

    Zhan, Ping; Tian, Honglei; Zhang, Xiaoming; Wang, Liping

    2013-03-15

    Changes in the aroma characteristics of mutton process flavors (MPFs) prepared from sheep bone protein hydrolysates (SBPHs) with different degrees of hydrolysis (DH) were evaluated using gas chromatography-mass spectrometry (GC-MS), gas chromatography-olfactometry (GC-O), and descriptive sensory analysis (DSA). Five attributes (muttony, meaty, roasted, mouthful, and simulate) were selected to assess MPFs. The results of DSA showed a distinct difference among the control sample MPF0 and other MPF samples with added SBPHs for different DHs of almost all sensory attributes. MPF5 (DH 25.92%) was the strongest in the muttony, meaty, and roasted attributes, whereas MPF6 (DH 30.89%) was the strongest in the simulate and roasted attributes. Thirty-six compounds were identified as odor-active compounds for the evaluation of the sensory characteristics of MPFs via GC-MS-O analysis. The results of correlation analysis among odor-active compounds, molecular weight, and DSA further confirmed that the SBPH with a DH range of 25.92-30.89% may be a desirable precursor for the sensory characteristics of MPF. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Effective Intraluminal Shunt in Carotid Endarterectomy for Carotid Artery Near Occlusion: Technical Report.

    PubMed

    Kawamura, Yoichiro; Maruyama, Daisuke; Akagi, Yojiro; Iihara, Koji

    2017-10-01

    Carotid artery near occlusion is a critical degree of stenosis whereby blood flow is decreased and the distal cervical and intracranial internal carotid arteries (ICAs) are prone to collapse. Considering the diminished perfusion and risk of progression to total occlusion and periocclusive embolism, we performed carotid endarterectomy for carotid artery near occlusion. Accurate evaluation of tandem stenosis or patency of the poststenotic ICA in carotid artery near occlusion is often difficult preoperatively. Thus we performed carotid endarterectomy in a hybrid operating room where intraoperative digital subtraction angiography (DSA) and endovascular angioplasty or stenting for distal lesions can be performed if necessary. In addition, to evaluate the distal ICA intraoperatively, we used an intraluminal shunt for shunt angiography, with injection of contrast material through the shunt tube, as a replacement for conventional DSA. Furthermore, an intraluminal shunt held the collapsed lumen open and provided a scaffold for suturing, which prevented postoperative stenosis of the distal ICA. The present report is intended to underline the merits of intraluminal shunt as a replacement for conventional DSA and as a scaffold for suturing. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Improvement in electron-beam lithography throughput by exploiting relaxed patterning fidelity requirements with directed self-assembly

    NASA Astrophysics Data System (ADS)

    Yu, Hao Yun; Liu, Chun-Hung; Shen, Yu Tian; Lee, Hsuan-Ping; Tsai, Kuen Yu

    2014-03-01

    Line edge roughness (LER) influencing the electrical performance of circuit components is a key challenge for electronbeam lithography (EBL) due to the continuous scaling of technology feature sizes. Controlling LER within an acceptable tolerance that satisfies International Technology Roadmap for Semiconductors requirements while achieving high throughput become a challenging issue. Although lower dosage and more-sensitive resist can be used to improve throughput, they would result in serious LER-related problems because of increasing relative fluctuation in the incident positions of electrons. Directed self-assembly (DSA) is a promising technique to relax LER-related pattern fidelity (PF) requirements because of its self-healing ability, which may benefit throughput. To quantify the potential of throughput improvement in EBL by introducing DSA for post healing, rigorous numerical methods are proposed to simultaneously maximize throughput by adjusting writing parameters of EBL systems subject to relaxed LER-related PF requirements. A fast, continuous model for parameter sweeping and a hybrid model for more accurate patterning prediction are employed for the patterning simulation. The tradeoff between throughput and DSA self-healing ability is investigated. Preliminary results indicate that significant throughput improvements are achievable at certain process conditions.

  8. Search for a Signature of Interaction between Relativistic Jet and Progenitor in Gamma-Ray Bursts

    NASA Astrophysics Data System (ADS)

    Yoshida, Kazuki; Yoneoku, Daisuke; Sawano, Tatsuya; Ito, Hirotaka; Matsumoto, Jin; Nagataki, Shigehiro

    2017-11-01

    The time variability of prompt emission in gamma-ray bursts (GRBs) is expected to originate from the temporal behavior of the central engine activity and the jet propagation in the massive stellar envelope. Using a pulse search algorithm for bright GRBs, we investigate the time variability of gamma-ray light curves to search a signature of the interaction between the jet and the inner structure of the progenitor. Since this signature might appear in the earlier phase of prompt emission, we divide the light curves into the initial phase and the late phase by referring to the trigger time and the burst duration of each GRB. We also adopt this algorithm for GRBs associated with supernovae/hypernovae that certainly are accompanied by massive stars. However, there is no difference between each pulse interval distribution described by a lognorma distribution in the two phases. We confirm that this result can be explained by the photospheric emission model if the energy injection of the central engine is not steady or completely periodic but episodic and described by the lognormal distribution with a mean of ˜1 s.

  9. Polarimetric Signatures of Initiating Convection During MC3E

    NASA Technical Reports Server (NTRS)

    Emory, Amber

    2012-01-01

    One of the goals of the Mid-latitude Continental Convective Clouds Experiment (MC3E) field campaign was to provide constraints for space-based rainfall retrieval algorithms over land. This study used datasets collected during the 2011 field campaign to combine radiometer and ground-based radar polarimetric retrievals in order to better understand hydrometeor type, habit and distribution for initiating continental convection. Cross-track and conically scanning nadir views from the Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) were compared with ground-based polarimetric radar retrievals along the ER-2 flight track. Polarimetric signatures for both airborne radiometers and ground-based radars were well co-located with deep convection to relate radiometric signatures with low-level polarimetric radar data for hydrometeor identification and diameter estimation. For the time period of study, Z(sub DR) values indicated no presence of hail at the surface. However, the Z(sub DR) column extended well above the melting level into the mixed phase region, suggesting a possible source of frozen drop embryos for the future formation of hail. The results shown from this study contribute ground truth datasets for GPM PR algorithm development for convective events, which is an improvement upon previous stratiform precipitation centered framework.

  10. Search for a Signature of Interaction between Relativistic Jet and Progenitor in Gamma-Ray Bursts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoshida, Kazuki; Yoneoku, Daisuke; Sawano, Tatsuya

    The time variability of prompt emission in gamma-ray bursts (GRBs) is expected to originate from the temporal behavior of the central engine activity and the jet propagation in the massive stellar envelope. Using a pulse search algorithm for bright GRBs, we investigate the time variability of gamma-ray light curves to search a signature of the interaction between the jet and the inner structure of the progenitor. Since this signature might appear in the earlier phase of prompt emission, we divide the light curves into the initial phase and the late phase by referring to the trigger time and the burstmore » duration of each GRB. We also adopt this algorithm for GRBs associated with supernovae/hypernovae that certainly are accompanied by massive stars. However, there is no difference between each pulse interval distribution described by a lognorma distribution in the two phases. We confirm that this result can be explained by the photospheric emission model if the energy injection of the central engine is not steady or completely periodic but episodic and described by the lognormal distribution with a mean of ∼1 s.« less

  11. Top-attack modeling and automatic target detection using synthetic FLIR scenery

    NASA Astrophysics Data System (ADS)

    Weber, Bruce A.; Penn, Joseph A.

    2004-09-01

    A series of experiments have been performed to verify the utility of algorithmic tools for the modeling and analysis of cold-target signatures in synthetic, top-attack, FLIR video sequences. The tools include: MuSES/CREATION for the creation of synthetic imagery with targets, an ARL target detection algorithm to detect imbedded synthetic targets in scenes, and an ARL scoring algorithm, using Receiver-Operating-Characteristic (ROC) curve analysis, to evaluate detector performance. Cold-target detection variability was examined as a function of target emissivity, surrounding clutter type, and target placement in non-obscuring clutter locations. Detector metrics were also individually scored so as to characterize the effect of signature/clutter variations. Results show that using these tools, a detailed, physically meaningful, target detection analysis is possible and that scenario specific target detectors may be developed by selective choice and/or weighting of detector metrics. However, developing these tools into a reliable predictive capability will require the extension of these results to the modeling and analysis of a large number of data sets configured for a wide range of target and clutter conditions. Finally, these tools should also be useful for the comparison of competitive detection algorithms by providing well defined, and controllable target detection scenarios, as well as for the training and testing of expert human observers.

  12. Integration of On-Line and Off-Line Diagnostic Algorithms for Aircraft Engine Health Management

    NASA Technical Reports Server (NTRS)

    Kobayashi, Takahisa; Simon, Donald L.

    2007-01-01

    This paper investigates the integration of on-line and off-line diagnostic algorithms for aircraft gas turbine engines. The on-line diagnostic algorithm is designed for in-flight fault detection. It continuously monitors engine outputs for anomalous signatures induced by faults. The off-line diagnostic algorithm is designed to track engine health degradation over the lifetime of an engine. It estimates engine health degradation periodically over the course of the engine s life. The estimate generated by the off-line algorithm is used to update the on-line algorithm. Through this integration, the on-line algorithm becomes aware of engine health degradation, and its effectiveness to detect faults can be maintained while the engine continues to degrade. The benefit of this integration is investigated in a simulation environment using a nonlinear engine model.

  13. Gamma signatures of the C-BORD Tagged Neutron Inspection System

    NASA Astrophysics Data System (ADS)

    Sardet, A.; Pérot, B.; Carasco, C.; Sannié, G.; Moretto, S.; Nebbia, G.; Fontana, C.; Pino, F.; Iovene, A.; Tintori, C.

    2018-01-01

    In the frame of C-BORD project (H2020 program of the EU), a Rapidly relocatable Tagged Neutron Inspection System (RRTNIS) is being developed to non-intrusively detect explosives, chemical threats, and other illicit goods in cargo containers. Material identification is performed through gamma spectroscopy, using twenty NaI detectors and four LaBr3 detectors, to determine the different elements composing the inspected item from their specific gamma signatures induced by fast neutrons. This is performed using an unfolding algorithm to decompose the energy spectrum of a suspect item, selected by X-ray radiography and on which the RRTNIS inspection is focused, on a database of pure element gamma signatures. This paper reports on simulated signatures for the NaI and LaBr3 detectors, constructed using the MCNP6 code. First experimental spectra of a few elements of interest are also presented.

  14. Propeller performance analysis and multidisciplinary optimization using a genetic algorithm

    NASA Astrophysics Data System (ADS)

    Burger, Christoph

    A propeller performance analysis program has been developed and integrated into a Genetic Algorithm for design optimization. The design tool will produce optimal propeller geometries for a given goal, which includes performance and/or acoustic signature. A vortex lattice model is used for the propeller performance analysis and a subsonic compact source model is used for the acoustic signature determination. Compressibility effects are taken into account with the implementation of Prandtl-Glauert domain stretching. Viscous effects are considered with a simple Reynolds number based model to account for the effects of viscosity in the spanwise direction. An empirical flow separation model developed from experimental lift and drag coefficient data of a NACA 0012 airfoil is included. The propeller geometry is generated using a recently introduced Class/Shape function methodology to allow for efficient use of a wide design space. Optimizing the angle of attack, the chord, the sweep and the local airfoil sections, produced blades with favorable tradeoffs between single and multiple point optimizations of propeller performance and acoustic noise signatures. Optimizations using a binary encoded IMPROVE(c) Genetic Algorithm (GA) and a real encoded GA were obtained after optimization runs with some premature convergence. The newly developed real encoded GA was used to obtain the majority of the results which produced generally better convergence characteristics when compared to the binary encoded GA. The optimization trade-offs show that single point optimized propellers have favorable performance, but circulation distributions were less smooth when compared to dual point or multiobjective optimizations. Some of the single point optimizations generated propellers with proplets which show a loading shift to the blade tip region. When noise is included into the objective functions some propellers indicate a circulation shift to the inboard sections of the propeller as well as a reduction in propeller diameter. In addition the propeller number was increased in some optimizations to reduce the acoustic blade signature.

  15. Hyperspectral and Hypertemporal Longwave Infrared Data Characterization

    NASA Astrophysics Data System (ADS)

    Jeganathan, Nirmalan

    The Army Research Lab conducted a persistent imaging experiment called the Spectral and Polarimetric Imagery Collection Experiment (SPICE) in 2012 and 2013 which focused on collecting and exploiting long wave infrared hyperspectral and polarimetric imagery. A part of this dataset was made for public release for research and development purposes. This thesis investigated the hyperspectral portion of this released dataset through data characterization and scene characterization of man-made and natural objects. First, the data were contrasted with MODerate resolution atmospheric TRANsmission (MODTRAN) results and found to be comparable. Instrument noise was characterized using an in-scene black panel, and was found to be comparable with the sensor manufacturer's specication. The temporal and spatial variation of certain objects in the scene were characterized. Temporal target detection was conducted on man-made objects in the scene using three target detection algorithms: spectral angle mapper (SAM), spectral matched lter (SMF) and adaptive coherence/cosine estimator (ACE). SMF produced the best results for detecting the targets when the training and testing data originated from different time periods, with a time index percentage result of 52.9%. Unsupervised and supervised classification were conducted using spectral and temporal target signatures. Temporal target signatures produced better visual classification than spectral target signature for unsupervised classification. Supervised classification yielded better results using the spectral target signatures, with a highest weighted accuracy of 99% for 7-class reference image. Four emissivity retrieval algorithms were applied on this dataset. However, the retrieved emissivities from all four methods did not represent true material emissivity and could not be used for analysis. This spectrally and temporally rich dataset enabled to conduct analysis that was not possible with other data collections. Regarding future work, applying noise-reduction techniques before applying temperature-emissivity retrieval algorithms may produce more realistic emissivity values, which could be used for target detection and material identification.

  16. Track-Before-Detect Algorithm for Faint Moving Objects based on Random Sampling and Consensus

    NASA Astrophysics Data System (ADS)

    Dao, P.; Rast, R.; Schlaegel, W.; Schmidt, V.; Dentamaro, A.

    2014-09-01

    There are many algorithms developed for tracking and detecting faint moving objects in congested backgrounds. One obvious application is detection of targets in images where each pixel corresponds to the received power in a particular location. In our application, a visible imager operated in stare mode observes geostationary objects as fixed, stars as moving and non-geostationary objects as drifting in the field of view. We would like to achieve high sensitivity detection of the drifters. The ability to improve SNR with track-before-detect (TBD) processing, where target information is collected and collated before the detection decision is made, allows respectable performance against dim moving objects. Generally, a TBD algorithm consists of a pre-processing stage that highlights potential targets and a temporal filtering stage. However, the algorithms that have been successfully demonstrated, e.g. Viterbi-based and Bayesian-based, demand formidable processing power and memory. We propose an algorithm that exploits the quasi constant velocity of objects, the predictability of the stellar clutter and the intrinsically low false alarm rate of detecting signature candidates in 3-D, based on an iterative method called "RANdom SAmple Consensus” and one that can run real-time on a typical PC. The technique is tailored for searching objects with small telescopes in stare mode. Our RANSAC-MT (Moving Target) algorithm estimates parameters of a mathematical model (e.g., linear motion) from a set of observed data which contains a significant number of outliers while identifying inliers. In the pre-processing phase, candidate blobs were selected based on morphology and an intensity threshold that would normally generate unacceptable level of false alarms. The RANSAC sampling rejects candidates that conform to the predictable motion of the stars. Data collected with a 17 inch telescope by AFRL/RH and a COTS lens/EM-CCD sensor by the AFRL/RD Satellite Assessment Center is used to assess the performance of the algorithm. In the second application, a visible imager operated in sidereal mode observes geostationary objects as moving, stars as fixed except for field rotation, and non-geostationary objects as drifting. RANSAC-MT is used to detect the drifter. In this set of data, the drifting space object was detected at a distance of 13800 km. The AFRL/RH set of data, collected in the stare mode, contained the signature of two geostationary satellites. The signature of a moving object was simulated and added to the sequence of frames to determine the sensitivity in magnitude. The performance compares well with the more intensive TBD algorithms reported in the literature.

  17. Real-time Upstream Monitoring System (RUMS): Forecasting arrival times of interplanetary shocks using energetic particle data from ACE

    NASA Astrophysics Data System (ADS)

    Ho, G.; Donegan, M.; Vandegriff, J.; Wagstaff, K.

    We have created a system for predicting the arrival times at Earth of interplanetary (IP) shocks that originate at the Sun. This system is currently available on the web (http://sd-www.jhuapl.edu/UPOS/RISP/index.html) and runs in real-time. Input data to our prediction algorithm is energetic particle data from the Electron, Proton, and Alpha Monitor (EPAM) instrument on NASA's Advanced Composition Explorer (ACE) spacecraft. Real-time EPAM data is obtained from the National Oceanic and Atmospheric Administration (NOAA) Space Environment Center (SEC). Our algorithm operates in two stages. First it watches for a velocity dispersion signature (energetic ions show flux enhancement followed by subsequent enhancements in lower energies), which is commonly seen upstream of a large IP shock. Once a precursor signature has been detected, a pattern recognition algorithm is used to analyze the time series profile of the particle data and generate an estimate for the shock arrival time. Tests on the algorithm show an average error of roughly 9 hours for predictions made 24 hours before the shock arrival and roughly 5 hours when the shock is 12 hours away. This can provide significant lead-time and deliver critical information to mission planners, satellite operations controllers, and scientists. As of February 4, 2004, the ACE real-time stream has been switched to include data from another detector on EPAM. We are now processing the new real-time data stream and have made improvements to our algorithm based on this data. In this paper, we report prediction results from the updated algorithm.

  18. An Improved Arbitrated Quantum Scheme with Bell States

    NASA Astrophysics Data System (ADS)

    Zhang, Yingying; Zeng, Jiwen

    2018-04-01

    In 2014, Liu et al. (In. J. Thero. phys. 53(5); 1569-1579. 2014) proposed an arbitrated quantum signature scheme (Liu'14) with Bell states by utilizing a new quantum one-time pad algorithm. It claimed that it can resist the receiver's existential forgery attack and no party has chances to change the message and its signature without being discovered. Recently, Xu and Zou (In. J. Thero. phys. 55; 4142-4156. 2016) analyzed above scheme and demonstrated that it can't resist the signer's disavowal and the receiver's existential forgery. But, the authors didn't give a method to solve it. In this paper, we will give an improved arbitrated quantum signature scheme to make up the loopholes in Liu'14.

  19. Recent advances and remaining challenges for the spectroscopic detection of explosive threats.

    PubMed

    Fountain, Augustus W; Christesen, Steven D; Moon, Raphael P; Guicheteau, Jason A; Emmons, Erik D

    2014-01-01

    In 2010, the U.S. Army initiated a program through the Edgewood Chemical Biological Center to identify viable spectroscopic signatures of explosives and initiate environmental persistence, fate, and transport studies for trace residues. These studies were ultimately designed to integrate these signatures into algorithms and experimentally evaluate sensor performance for explosives and precursor materials in existing chemical point and standoff detection systems. Accurate and validated optical cross sections and signatures are critical in benchmarking spectroscopic-based sensors. This program has provided important information for the scientists and engineers currently developing trace-detection solutions to the homemade explosive problem. With this information, the sensitivity of spectroscopic methods for explosives detection can now be quantitatively evaluated before the sensor is deployed and tested.

  20. SHAMROCK: A Synthesizable High Assurance Cryptography and Key Management Coprocessor

    DTIC Science & Technology

    2016-11-01

    and excluding devices from a communicating group as they become trusted, or untrusted. An example of using rekeying to dynamically adjust group...algorithms, such as the Elliptic Curve Digital Signature Algorithm (ECDSA), work by computing a cryptographic hash of a message using, for example , the...material is based upon work supported by the Assistant Secretary of Defense for Research and Engineering under Air Force Contract No. FA8721- 05-C

  1. Self-adaptive road tracking in hyperspectral data for C-IED

    NASA Astrophysics Data System (ADS)

    Schilling, Hendrik; Gross, Wolfgang; Middelmann, Wolfgang

    2012-09-01

    For Counter Improvised Explosive Devices purposes, main routes including their vicinity are surveyed. In future military operations, small hyperspectral sensors will be used for ground covering reconnaissance, complementing images from infrared and high resolution sensors. They will be mounted on unmanned airborne vehicles and are used for on-line monitoring of convoy routes. Depending of the proximity to the road, different regions can be defined for threat assessment. Automatic road tracking can help choosing the correct areas of interest. Often, the exact discrimination between road and surroundings fails in conventional methods due to low contrast in pan-chromatic images at the road boundaries or occlusions. In this contribution, a novel real-time lock-on road tracking algorithm is introduced. It uses hyperspectral data and is specifically designed to address the afore- mentioned deficiencies of conventional methods. Local features are calculated from the high-resolution spectral signatures. They describe the similarity to the actual road cover and to either roadside. Classification is per- formed to discriminate the signatures. To improve robustness against variations in road cover, the classification results are used to progressively adapt the road and roadside classes. Occlusions are treated by predicting the course of the road and comparing the signatures in the target area to previously determined road cover signa- tures. The algorithm can be easily extended to show regions of varying threat, depending on the distance to the road. Thus, complex anomaly detectors and classification algorithms can be applied to a reduced data set. First experiments were performed for AISA Eagle II (400nm - 970nm) and AISA Hawk (970nm - 2450nm) data

  2. Kinetic Simulations of Particle Acceleration at Shocks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caprioli, Damiano; Guo, Fan

    2015-07-16

    Collisionless shocks are mediated by collective electromagnetic interactions and are sources of non-thermal particles and emission. The full particle-in-cell approach and a hybrid approach are sketched, simulations of collisionless shocks are shown using a multicolor presentation. Results for SN 1006, a case involving ion acceleration and B field amplification where the shock is parallel, are shown. Electron acceleration takes place in planetary bow shocks and galaxy clusters. It is concluded that acceleration at shocks can be efficient: >15%; CRs amplify B field via streaming instability; ion DSA is efficient at parallel, strong shocks; ions are injected via reflection and shockmore » drift acceleration; and electron DSA is efficient at oblique shocks.« less

  3. Implications for high speed research: The relationship between sonic boom signature distortion and atmospheric turbulence

    NASA Technical Reports Server (NTRS)

    Sparrow, Victor W.; Gionfriddo, Thomas A.

    1994-01-01

    In this study there were two primary tasks. The first was to develop an algorithm for quantifying the distortion in a sonic boom. Such an algorithm should be somewhat automatic, with minimal human intervention. Once the algorithm was developed, it was used to test the hypothesis that the cause of a sonic boom distortion was due to atmospheric turbulence. This hypothesis testing was the second task. Using readily available sonic boom data, we statistically tested whether there was a correlation between the sonic boom distortion and the distance a boom traveled through atmospheric turbulence.

  4. Detrending the realized volatility in the global FX market

    NASA Astrophysics Data System (ADS)

    Schmidt, Anatoly B.

    2009-05-01

    There has been growing interest in realized volatility (RV) of financial assets that is calculated using intra-day returns. The choice of optimal time grid for these calculations is not trivial and generally requires analysis of RV dependence on the grid spacing (so-called RV signature). Typical RV signatures have a maximum at the finest time grid spacing available, which is attributed to the microstructure effects. This maximum decays into a plateau at lower frequencies, which implies (almost) stationary return variance. We found that the RV signatures in the modern global FX market may have no plateau or even have a maximum at lower frequencies. Simple averaging methods used to address the microstructure effects in equities have no practical effect on the FX RV signatures. We show that local detrending of the high-frequency FX rate samples yields RV signatures with a pronounced plateau. This implies that FX rates can be described with a Brownian motion having non-stationary trend and stationary variance. We point at a role of algorithmic trading as a possible cause of micro-trends in FX rates.

  5. Deep Learning Predicts Correlation between a Functional Signature of Higher Visual Areas and Sparse Firing of Neurons.

    PubMed

    Zhuang, Chengxu; Wang, Yulong; Yamins, Daniel; Hu, Xiaolin

    2017-01-01

    Visual information in the visual cortex is processed in a hierarchical manner. Recent studies show that higher visual areas, such as V2, V3, and V4, respond more vigorously to images with naturalistic higher-order statistics than to images lacking them. This property is a functional signature of higher areas, as it is much weaker or even absent in the primary visual cortex (V1). However, the mechanism underlying this signature remains elusive. We studied this problem using computational models. In several typical hierarchical visual models including the AlexNet, VggNet, and SHMAX, this signature was found to be prominent in higher layers but much weaker in lower layers. By changing both the model structure and experimental settings, we found that the signature strongly correlated with sparse firing of units in higher layers but not with any other factors, including model structure, training algorithm (supervised or unsupervised), receptive field size, and property of training stimuli. The results suggest an important role of sparse neuronal activity underlying this special feature of higher visual areas.

  6. Deep Learning Predicts Correlation between a Functional Signature of Higher Visual Areas and Sparse Firing of Neurons

    PubMed Central

    Zhuang, Chengxu; Wang, Yulong; Yamins, Daniel; Hu, Xiaolin

    2017-01-01

    Visual information in the visual cortex is processed in a hierarchical manner. Recent studies show that higher visual areas, such as V2, V3, and V4, respond more vigorously to images with naturalistic higher-order statistics than to images lacking them. This property is a functional signature of higher areas, as it is much weaker or even absent in the primary visual cortex (V1). However, the mechanism underlying this signature remains elusive. We studied this problem using computational models. In several typical hierarchical visual models including the AlexNet, VggNet, and SHMAX, this signature was found to be prominent in higher layers but much weaker in lower layers. By changing both the model structure and experimental settings, we found that the signature strongly correlated with sparse firing of units in higher layers but not with any other factors, including model structure, training algorithm (supervised or unsupervised), receptive field size, and property of training stimuli. The results suggest an important role of sparse neuronal activity underlying this special feature of higher visual areas. PMID:29163117

  7. Prioritizing Therapeutics for Lung Cancer: An Integrative Meta-analysis of Cancer Gene Signatures and Chemogenomic Data

    PubMed Central

    Fortney, Kristen; Griesman, Joshua; Kotlyar, Max; Pastrello, Chiara; Angeli, Marc; Sound-Tsao, Ming; Jurisica, Igor

    2015-01-01

    Repurposing FDA-approved drugs with the aid of gene signatures of disease can accelerate the development of new therapeutics. A major challenge to developing reliable drug predictions is heterogeneity. Different gene signatures of the same disease or drug treatment often show poor overlap across studies, as a consequence of both biological and technical variability, and this can affect the quality and reproducibility of computational drug predictions. Existing algorithms for signature-based drug repurposing use only individual signatures as input. But for many diseases, there are dozens of signatures in the public domain. Methods that exploit all available transcriptional knowledge on a disease should produce improved drug predictions. Here, we adapt an established meta-analysis framework to address the problem of drug repurposing using an ensemble of disease signatures. Our computational pipeline takes as input a collection of disease signatures, and outputs a list of drugs predicted to consistently reverse pathological gene changes. We apply our method to conduct the largest and most systematic repurposing study on lung cancer transcriptomes, using 21 signatures. We show that scaling up transcriptional knowledge significantly increases the reproducibility of top drug hits, from 44% to 78%. We extensively characterize drug hits in silico, demonstrating that they slow growth significantly in nine lung cancer cell lines from the NCI-60 collection, and identify CALM1 and PLA2G4A as promising drug targets for lung cancer. Our meta-analysis pipeline is general, and applicable to any disease context; it can be applied to improve the results of signature-based drug repurposing by leveraging the large number of disease signatures in the public domain. PMID:25786242

  8. Magnetic resonance imaging-based cerebral tissue classification reveals distinct spatiotemporal patterns of changes after stroke in non-human primates.

    PubMed

    Bouts, Mark J R J; Westmoreland, Susan V; de Crespigny, Alex J; Liu, Yutong; Vangel, Mark; Dijkhuizen, Rick M; Wu, Ona; D'Arceuil, Helen E

    2015-12-15

    Spatial and temporal changes in brain tissue after acute ischemic stroke are still poorly understood. Aims of this study were three-fold: (1) to determine unique temporal magnetic resonance imaging (MRI) patterns at the acute, subacute and chronic stages after stroke in macaques by combining quantitative T2 and diffusion MRI indices into MRI 'tissue signatures', (2) to evaluate temporal differences in these signatures between transient (n = 2) and permanent (n = 2) middle cerebral artery occlusion, and (3) to correlate histopathology findings in the chronic stroke period to the acute and subacute MRI derived tissue signatures. An improved iterative self-organizing data analysis algorithm was used to combine T2, apparent diffusion coefficient (ADC), and fractional anisotropy (FA) maps across seven successive timepoints (1, 2, 3, 24, 72, 144, 240 h) which revealed five temporal MRI signatures, that were different from the normal tissue pattern (P < 0.001). The distribution of signatures between brains with permanent and transient occlusions varied significantly between groups (P < 0.001). Qualitative comparisons with histopathology revealed that these signatures represented regions with different histopathology. Two signatures identified areas of progressive injury marked by severe necrosis and the presence of gitter cells. Another signature identified less severe but pronounced neuronal and axonal degeneration, while the other signatures depicted tissue remodeling with vascular proliferation and astrogliosis. These exploratory results demonstrate the potential of temporally and spatially combined voxel-based methods to generate tissue signatures that may correlate with distinct histopathological features. The identification of distinct ischemic MRI signatures associated with specific tissue fates may further aid in assessing and monitoring the efficacy of novel pharmaceutical treatments for stroke in a pre-clinical and clinical setting.

  9. A Systematic Comparison of Linear Regression-Based Statistical Methods to Assess Exposome-Health Associations.

    PubMed

    Agier, Lydiane; Portengen, Lützen; Chadeau-Hyam, Marc; Basagaña, Xavier; Giorgis-Allemand, Lise; Siroux, Valérie; Robinson, Oliver; Vlaanderen, Jelle; González, Juan R; Nieuwenhuijsen, Mark J; Vineis, Paolo; Vrijheid, Martine; Slama, Rémy; Vermeulen, Roel

    2016-12-01

    The exposome constitutes a promising framework to improve understanding of the effects of environmental exposures on health by explicitly considering multiple testing and avoiding selective reporting. However, exposome studies are challenged by the simultaneous consideration of many correlated exposures. We compared the performances of linear regression-based statistical methods in assessing exposome-health associations. In a simulation study, we generated 237 exposure covariates with a realistic correlation structure and with a health outcome linearly related to 0 to 25 of these covariates. Statistical methods were compared primarily in terms of false discovery proportion (FDP) and sensitivity. On average over all simulation settings, the elastic net and sparse partial least-squares regression showed a sensitivity of 76% and an FDP of 44%; Graphical Unit Evolutionary Stochastic Search (GUESS) and the deletion/substitution/addition (DSA) algorithm revealed a sensitivity of 81% and an FDP of 34%. The environment-wide association study (EWAS) underperformed these methods in terms of FDP (average FDP, 86%) despite a higher sensitivity. Performances decreased considerably when assuming an exposome exposure matrix with high levels of correlation between covariates. Correlation between exposures is a challenge for exposome research, and the statistical methods investigated in this study were limited in their ability to efficiently differentiate true predictors from correlated covariates in a realistic exposome context. Although GUESS and DSA provided a marginally better balance between sensitivity and FDP, they did not outperform the other multivariate methods across all scenarios and properties examined, and computational complexity and flexibility should also be considered when choosing between these methods. Citation: Agier L, Portengen L, Chadeau-Hyam M, Basagaña X, Giorgis-Allemand L, Siroux V, Robinson O, Vlaanderen J, González JR, Nieuwenhuijsen MJ, Vineis P, Vrijheid M, Slama R, Vermeulen R. 2016. A systematic comparison of linear regression-based statistical methods to assess exposome-health associations. Environ Health Perspect 124:1848-1856; http://dx.doi.org/10.1289/EHP172.

  10. High reliability - low noise radionuclide signature identification algorithms for border security applications

    NASA Astrophysics Data System (ADS)

    Lee, Sangkyu

    Illicit trafficking and smuggling of radioactive materials and special nuclear materials (SNM) are considered as one of the most important recent global nuclear threats. Monitoring the transport and safety of radioisotopes and SNM are challenging due to their weak signals and easy shielding. Great efforts worldwide are focused at developing and improving the detection technologies and algorithms, for accurate and reliable detection of radioisotopes of interest in thus better securing the borders against nuclear threats. In general, radiation portal monitors enable detection of gamma and neutron emitting radioisotopes. Passive or active interrogation techniques, present and/or under the development, are all aimed at increasing accuracy, reliability, and in shortening the time of interrogation as well as the cost of the equipment. Equally important efforts are aimed at advancing algorithms to process the imaging data in an efficient manner providing reliable "readings" of the interiors of the examined volumes of various sizes, ranging from cargos to suitcases. The main objective of this thesis is to develop two synergistic algorithms with the goal to provide highly reliable - low noise identification of radioisotope signatures. These algorithms combine analysis of passive radioactive detection technique with active interrogation imaging techniques such as gamma radiography or muon tomography. One algorithm consists of gamma spectroscopy and cosmic muon tomography, and the other algorithm is based on gamma spectroscopy and gamma radiography. The purpose of fusing two detection methodologies per algorithm is to find both heavy-Z radioisotopes and shielding materials, since radionuclides can be identified with gamma spectroscopy, and shielding materials can be detected using muon tomography or gamma radiography. These combined algorithms are created and analyzed based on numerically generated images of various cargo sizes and materials. In summary, the three detection methodologies are fused into two algorithms with mathematical functions providing: reliable identification of radioisotopes in gamma spectroscopy; noise reduction and precision enhancement in muon tomography; and the atomic number and density estimation in gamma radiography. It is expected that these new algorithms maybe implemented at portal scanning systems with the goal to enhance the accuracy and reliability in detecting nuclear materials inside the cargo containers.

  11. Sugar-Binding Profiles of Chitin-Binding Lectins from the Hevein Family: A Comprehensive Study

    PubMed Central

    Itakura, Yoko; Nakamura-Tsuruta, Sachiko; Kominami, Junko; Tateno, Hiroaki; Hirabayashi, Jun

    2017-01-01

    Chitin-binding lectins form the hevein family in plants, which are defined by the presence of single or multiple structurally conserved GlcNAc (N-acetylglucosamine)-binding domains. Although they have been used as probes for chito-oligosaccharides, their detailed specificities remain to be investigated. In this study, we analyzed six chitin-binding lectins, DSA, LEL, PWM, STL, UDA, and WGA, by quantitative frontal affinity chromatography. Some novel features were evident: WGA showed almost comparable affinity for pyridylaminated chitotriose and chitotetraose, while LEL and UDA showed much weaker affinity, and DSA, PWM, and STL had no substantial affinity for the former. WGA showed selective affinity for hybrid-type N-glycans harboring a bisecting GlcNAc residue. UDA showed extensive binding to high-mannose type N-glycans, with affinity increasing with the number of Man residues. DSA showed the highest affinity for highly branched N-glycans consisting of type II LacNAc (N-acetyllactosamine). Further, multivalent features of these lectins were investigated by using glycoconjugate and lectin microarrays. The lectins showed substantial binding to immobilized LacNAc as well as chito-oligosaccharides, although the extents to which they bound varied among them. WGA showed strong binding to heavily sialylated glycoproteins. The above observations will help interpret lectin-glycoprotein interactions in histochemical studies and glyco-biomarker investigations. PMID:28556796

  12. [A Case of Cervical Spinal Dural Arteriovenous Fistula with Extradural Drainage Presenting with Subarachnoid Hemorrhage due to a Ruptured Anterior Spinal Artery Aneurysm].

    PubMed

    Kurokawa, Yasuharu; Ikawa, Fusao; Hamasaki, Osamu; Hidaka, Toshikazu; Yonezawa, Ushio; Komiyama, Masaki

    2015-09-01

    We report a rare case of a cervical spinal dural arteriovenous fistula(AVF)at the C2 level presenting with subarachnoid hemorrhage(SAH)due to a ruptured anterior spinal artery aneurysm. A 61-year-old man presented with sudden onset headache. Initial computed tomography revealed SAH around the brainstem. Digital subtraction angiography(DSA)demonstrated a cervical dural AVF that was fed by the left C1 radicular, left C2 radicular, and anterior spinal arteries, and drained into the epidural plexus. An aneurysm in the branch of the cervical anterior spinal artery was considered the bleeding point. A left lateral suboccipital craniotomy and C1 hemilaminectomy were performed on day 43. The feeding arteries were clipped, followed by coagulation of the draining veins. However, the aneurysm was not clipped because we deemed that obliteration of the aneurysm would be difficult without disrupting the blood flow of the parent artery. The patient showed no neurological deterioration after the operation. Postoperative DSA revealed residual dural AVF. Therefore, a second surgery was performed. After the second open surgery, DSA showed that the dural AVF and aneurysm disappeared. The patient also showed no neurological deterioration after the second surgery.

  13. Low vascularity predicts favourable outcomes in leiomyoma patients treated with uterine artery embolization.

    PubMed

    Tang, Yixin; Chen, Chunlin; Duan, Hui; Ma, Ben; Liu, Ping

    2016-10-01

    To investigate the clinical factors predicting outcomes of leiomyoma treated with uterine artery embolization (UAE). A total of 183 uterine leiomyoma patients undergoing UAE were retrospectively analyzed. Patient age, characteristics of vascular supply in magnetic resonance imaging (MRI)/digital subtraction angiography (DSA), number, size and location of leiomyoma were recorded. Leiomyoma regrowth, new leiomyoma appearance and recurrence of any previously reported symptoms were carefully monitored over a mean follow-up of 30 months (median 32 months, range 12-80). Potential recurrence risk factors were analyzed by univariate and multivariate cox regression analysis. Twenty-three recurrences were recorded. The difference in the vascularity classification systems between MRI and DSA was not statistically significant (P = 0.059). High vascularity in MRI, high vascularity in DSA and multiple leiomyoma showed a significant risk of recurrence using univariate and multivariate analysis (P = 0.004, P < 0.001 and P = 0.023, respectively). The other factors were not significantly associated with leiomyoma recurrence (P > 0.05). Low vascularity and solitary leiomyoma indicated favourable outcomes in patients treated with UAE. • Low vascularity and solitary mass predicted favourable outcomes in UAE-treated patients. • MRI might provide information on vascularity in leiomyoma before UAE. • Variations in vascular supply, age, size, location were not associated with recurrence.

  14. INJECTION TO RAPID DIFFUSIVE SHOCK ACCELERATION AT PERPENDICULAR SHOCKS IN PARTIALLY IONIZED PLASMAS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohira, Yutaka, E-mail: ohira@phys.aoyama.ac.jp

    2016-08-10

    We present a three-dimensional hybrid simulation of a collisionless perpendicular shock in a partially ionized plasma for the first time. In this simulation, the shock velocity and upstream ionization fraction are v {sub sh} ≈ 1333 km s{sup −1} and f {sub i} ∼ 0.5, which are typical values for isolated young supernova remnants (SNRs) in the interstellar medium. We confirm previous two-dimensional simulation results showing that downstream hydrogen atoms leak into the upstream region and are accelerated by the pickup process in the upstream region, and large magnetic field fluctuations are generated both in the upstream and downstream regions.more » In addition, we find that the magnetic field fluctuations have three-dimensional structures and the leaking hydrogen atoms are injected into the diffusive shock acceleration (DSA) at the perpendicular shock after the pickup process. The observed DSA can be interpreted as shock drift acceleration with scattering. In this simulation, particles are accelerated to v ∼ 100 v {sub sh} ∼ 0.3 c within ∼100 gyroperiods. The acceleration timescale is faster than that of DSA in parallel shocks. Our simulation results suggest that SNRs can accelerate cosmic rays to 10{sup 15.5} eV (the knee) during the Sedov phase.« less

  15. Successful Renal Transplantation with Desensitization in Highly Sensitized Patients: A Single Center Experience

    PubMed Central

    Yoon, Hye Eun; Hyoung, Bok Jin; Hwang, Hyeon Seok; Lee, So Young; Jeon, Youn Joo; Song, Joon Chang; Oh, Eun-Jee; Park, Sun Cheol; Choi, Bum Soon; Moon, In Sung; Kim, Yong Soo

    2009-01-01

    Intravenous immunoglobulin (IVIG) and/or plasmapheresis (PP) are effective in preventing antibody-mediated rejection (AMR) of kidney allografts, but AMR is still a problem. This study reports our experience in living donor renal transplantation in highly sensitized patients. Ten patients with positive crossmatch tests or high levels of panel-reactive antibody (PRA) were included. Eight patients were desensitized with pretransplant PP and low dose IVIG, and two were additionally treated with rituximab. Allograft function, number of acute rejection (AR) episodes, protocol biopsy findings, and the presence of donor-specific antibody (DSA) were evaluated. With PP/IVIG, six out of eight patients showed good graft function without AR episodes. Protocol biopsies revealed no evidence of tissue injury or C4d deposits. Of two patients with AR, one was successfully treated with PP/IVIG, but the other lost graft function due to de novo production of DSA. Thereafter, rituximab was added to PP/IVIG in two cases. Rituximab gradually decreased PRA levels and the percentage of peripheral CD20+ cells. DSA was undetectable and protocol biopsy showed no C4d deposits. The graft function was stable and there were no AR episodes. Conclusively, desensitization using PP/IVIG with or without rituximab increases the likelihood of successful living donor renal transplantation in sensitized recipients. PMID:19194545

  16. Gecko-inspired bidirectional double-sided adhesives.

    PubMed

    Wang, Zhengzhi; Gu, Ping; Wu, Xiaoping

    2014-05-14

    A new concept of gecko-inspired double-sided adhesives (DSAs) is presented. The DSAs, constructed by dual-angled (i.e. angled base and angled tip) micro-pillars on both sides of the backplane substrate, are fabricated by combinations of angled etching, mould replication, tip modification, and curing bonding. Two types of DSA, symmetric and antisymmetric (i.e. pillars are patterned symmetrically or antisymmetrically relative to the backplane), are fabricated and studied in comparison with the single-sided adhesive (SSA) counterparts through both non-conformal and conformal tests. Results indicate that the DSAs show controllable and bidirectional adhesion. Combination of the two pillar-layers can either amplify (for the antisymmetric DSA, providing a remarkable and durable adhesion capacity of 25.8 ± 2.8 N cm⁻² and a high anisotropy ratio of ∼8) or counteract (for the symmetric DSA, generating almost isotropic adhesion) the adhesion capacity and anisotropic level of one SSA (capacity of 16.2 ± 1.7 N cm⁻² and anisotropy ratio of ∼6). We demonstrate that these two DSAs can be utilized as a facile fastener for two individual objects and a small-scale delivery setup, respectively, complementing the functionality of the commonly studied SSA. As such, the double-sided patterning is believed to be a new branch in the further development of biomimetic dry adhesives.

  17. Soluble CD30 concentrations in ESRD patients with and without panel reactive HLA antibodies.

    PubMed

    Vaidya, Smita; Partlow, David; Barnes, Titus; Thomas, Phillip; Gugliuzza, Kristin

    2006-01-01

    In this retrospective study we compared accuracy of panel reactive antibodies (PRA) with serum soluble CD30 (sCD30) contents in predicting acute rejection crisis post-renal transplant. Pre-transplant sera from 115 patients were evaluated for their PRA and sCD30 concentrations. All patients received calcineurin inhibitor-based immunosuppressive therapy. Objective measurements for rejection were biopsy-proven acute rejection (AR) episodes within first six months of the transplant. Post-transplant sera of patients with AR were tested for the presence of donor-specific HLA antibodies (DSA). Overall AR rate was 16% (18/115). Patients positive for PRA and sCD30 tests were at significantly higher risk for AVR compared with those patients negative for both the tests (36% vs. 5%, p=0.01). Among negative PRA patients risk for AR was significantly elevated if they were also tested positive for sCD30 concentrations (21% vs. 5%, p=0.04). Of the 18 patients with AR, 14 were positive for sCD30, and 13 of them (93%) developed DSA post-transplant (p=0.001). These data showed that patients positive for sCD30 contents are at high risk for the development of DSA and AR post-transplant regardless of their pre-transplant PRA.

  18. Serrated yielding in Al-Li alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, S.; McShane, H.B.

    1993-05-01

    Serrated yielding (SY) during tensile testing has been observed in Al-Li alloys, both in the binary and the commercial quaternary alloys, in single crystal as well as polycrystalline materials. Serrated yielding is commonly explained by a dynamic strain aging (DSA) model developed by McCormick and van den Beukel. All the solute elements present in Al-Li alloys, viz., Mg, Cu and Li are known to give DSA and SY. Several researchers believe the DSA to be the cause of SY and they attribute the disappearance of SY simply to the removal of solute from the matrix with aging. However, this argumentmore » has serious flaws. The present paper examines this aspect critically. The authors concluded that Al-Li alloys the disappearance of serrated yielding at a certain stage of aging is not due to removal of the solute from the matrix but due to the change in the nature of the metastable [delta][prime] precipitates - from fine coherent shearable precipitates to larger noncoherent nonshearable precipitates - which prevents the formation of the deformation bands. The serrated yielding reappears with extensive over aging due to the dissolution of these precipitates in favor of the equilibrium precipitates. The equilibrium precipitates, being widely spaced, are ineffective in preventing the formation of deformation bands.« less

  19. Testing New Drugs for Treatment of Melanoma Patients Applying Connectivity Map Database Analysis with Melanoma Gene Signatures

    DTIC Science & Technology

    2012-10-01

    use of R packages implemented in Bioconductor. Each dataset was normalized from raw data using the Frozen RMA (fRMA) algorithm . We applied the same...because development of the specific algorithms and fine tuning of the analytic strategy to accomplish this task was not immediately straightforward. We...express firefly luciferase using a retrovirus that encodes a fusion of luciferase and neomycin phosphotransferase (LucNeo), will be implanted and followed

  20. Quantitative assessment of protein activity in orphan tissues and single cells using the metaVIPER algorithm. | Office of Cancer Genomics

    Cancer.gov

    We and others have shown that transition and maintenance of biological states is controlled by master regulator proteins, which can be inferred by interrogating tissue-specific regulatory models (interactomes) with transcriptional signatures, using the VIPER algorithm. Yet, some tissues may lack molecular profiles necessary for interactome inference (orphan tissues), or, as for single cells isolated from heterogeneous samples, their tissue context may be undetermined.

  1. miRvestigator: web application to identify miRNAs responsible for co-regulated gene expression patterns discovered through transcriptome profiling.

    PubMed

    Plaisier, Christopher L; Bare, J Christopher; Baliga, Nitin S

    2011-07-01

    Transcriptome profiling studies have produced staggering numbers of gene co-expression signatures for a variety of biological systems. A significant fraction of these signatures will be partially or fully explained by miRNA-mediated targeted transcript degradation. miRvestigator takes as input lists of co-expressed genes from Caenorhabditis elegans, Drosophila melanogaster, G. gallus, Homo sapiens, Mus musculus or Rattus norvegicus and identifies the specific miRNAs that are likely to bind to 3' un-translated region (UTR) sequences to mediate the observed co-regulation. The novelty of our approach is the miRvestigator hidden Markov model (HMM) algorithm which systematically computes a similarity P-value for each unique miRNA seed sequence from the miRNA database miRBase to an overrepresented sequence motif identified within the 3'-UTR of the query genes. We have made this miRNA discovery tool accessible to the community by integrating our HMM algorithm with a proven algorithm for de novo discovery of miRNA seed sequences and wrapping these algorithms into a user-friendly interface. Additionally, the miRvestigator web server also produces a list of putative miRNA binding sites within 3'-UTRs of the query transcripts to facilitate the design of validation experiments. The miRvestigator is freely available at http://mirvestigator.systemsbiology.net.

  2. Quantitative assessment of angiographic perfusion reduction using color-coded digital subtraction angiography during transarterial chemoembolization.

    PubMed

    Wang, Ji; Cheng, Jie-Jun; Huang, Kai-Yi; Zhuang, Zhi-Guo; Zhang, Xue-Bin; Chi, Jia-Chang; Hua, Xiao-Lan; Xu, Jian-Rong

    2016-03-01

    The aim of this study was to develop a quantitative measurement of perfusion reduction using color-coded digital subtraction angiography (ccDSA) to monitor intra-procedural arterial stasis during TACE. A total number of 35 patients with hepatocellular carcinoma who had undergone TACE were enrolled into the study. Pre- and post-two-dimensional digital subtraction angiography scans were conducted with same protocol and post-processed with ccDSA prototype software. Time-contrast-intensity (CI[t]) curve was obtained by region-of-interest (ROI) measurement on the generated ccDSA image. Quantitative 2D perfusion parameters time to peak, area under the curve (AUC), maximum upslope, and contrast intensity peak (CI-Peak) derived from the ROI-based CI[t] curve for pre- and post-TACE were evaluated to assess the reduction of antegrade blood flow and tumor blush. Relationships between 2D perfusion parameters, subjective angiographic chemoembolization endpoint (SACE) scale, and clinical outcomes were analyzed. Area normalized AUC and CI-Peak revealed significant reduction after the TACE (P < 0.0001). AUCnorm decreased from pre-procedure of 0.867 ± 0.242 to 0.421 ± 0.171 (P < 0.001) after completion of TACE. CI-Peaknorm was 0.739 ± 0.221 before TACE and 0.421 ± 0.174 (P < 0.001) after TACE. Tumor blood supply time slowed down obviously after embolization. A perfusion reduction either from AUCnorm or CI-Peaknorm ranging from 30% to 40% was associated with SACE level III and a reduction ranging from 60% to 70% was equivalent to SACE level IV. For intermediate reduction (SACE level III), better tumor response was found after TACE rather than a higher reduction (SACE level IV). ccDSA application provides an objective approach to quantify the perfusion reduction and subjectively evaluate the arterial stasis of antegrade blood flow and tumor blush caused by TACE.

  3. Collateral circulation via the circle of Willis in patients with carotid artery steno-occlusive disease: evaluation on 3-T 4D MRA using arterial spin labelling.

    PubMed

    Iryo, Yasuhiko; Hirai, Toshinori; Nakamura, Masanobu; Inoue, Yasuteru; Watanabe, Masaki; Ando, Yukio; Azuma, Minako; Nishimura, Shinichiro; Shigematsu, Yoshinori; Kitajima, Mika; Yamashita, Yasuyuki

    2015-09-01

    To evaluate whether 3-T four-dimensional (4D) arterial spin-labelling (ASL) -based magnetic resonance angiography (MRA) is useful for assessing the collateral circulation via the circle of Willis in patients with carotid artery steno-occlusive disease. Institutional review board approval and prior written informed consent from all patients were obtained. The inclusion criteria were fulfilled by 13 patients with carotid artery steno-occlusive disease. All underwent 4D-ASL MRA at 3 T and digital subtraction angiography (DSA). The flow-sensitive alternating inversion recovery (FAIR) preparation scheme with look-locker sampling was used for spin labeling. At 300-ms intervals seven dynamic scans were obtained with a spatial resolution of 0.5×0.5×0.6 mm(3). The collateral flow via the circle of Willis was read on 4D-ASL MRA and DSA images by two sets of two independent readers each. κ statistics were used to assess interobserver and intermodality agreement. On DSA, collateral flow via the anterior communicating artery (AcomA) was observed in six patients, via the posterior communicating artery (PcomA) in four patients, and via both the AcomA and PcomA in three patients. With respect to the qualitative evaluation of 4D-ASL MRA images, interobserver agreement was excellent for all items (κ=1). 4D-ASL MRA and DSA consensus readings agreed on the type of collateral flow pattern in 10 of the 13 patients (77%). Intermodality agreement was good (κ=0.606; 95% confidence interval (CI): 0.215-0.997). 3 T 4D-ASL MRA may be a useful tool for the evaluation of the collateral circulation in patients with carotid artery steno-occlusive disease. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buis, Dennis R.; Lagerwaard, Frank J.; Dirven, Clemens M.F.

    Purpose: To assess the dosimetric consequences of brain arteriovenous malformation (bAVM) delineation on magnetic resonance angiography (MRA) for the purpose of stereotactic radiosurgery. Methods and Materials: Three observers contoured a bAVM in 20 patients, using digital subtraction angiography (V{sub DSA}) and three-dimensional time-of-flight MRA (V{sub MRA}). Displacement between contours was calculated. Agreement and differences between observers and imaging modalities were assessed. A standardized treatment plan with dynamic conformal arcs was generated and dosimetric coverage of all contours and the volume of normal brain tissue within the high dose region was determined. Results: The generalized reliability coefficient was 'fair' for targetmore » volume (0.79), but 'poor' for displacement (0.35). V{sub MRA} was larger than V{sub DSA} (5.0 vs. 4.0 mL, p = 0.001). No difference in displacement was found (2.8 vs. 2.5 mm, p = 0.156). Dosimetric coverage of V{sub MRA} was 62.9% (95% CI, 56.9-68.8) when V{sub DSA} was used as planning target volume, and coverage of V{sub DSA} was 83.5% (95% CI, 78.1-88.8) when V{sub MRA} was used for planning (p < 0.001). The mean volume of normal brain within the 80% isodose was larger when the bAVM was delineated on MRA (0.7 vs. 1.0 mL (p = 0.02) for targets {<=}3 mL and 3.7 vs. 7.0 mL (p = 0.01) for targets >3 mL). Conclusions: Brain arteriovenous malformations delineated on MRA are larger and more randomly displaced. However, for bAVMs {<=}3 mL, the difference in volume of normal brain tissue within the high-dose region does not seem to be clinically relevant. Therefore, MRA-images might be used as the sole imaging modality for the radiosurgical treatment of bAVMs {<=}3 mL when the bAVM is located in a noneloquent position.« less

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nielsen, Yousef W., E-mail: yujwni01@heh.regionh.d; Eiberg, Jonas P.; Logager, Vibeke B.

    The purpose of this investigation was to determine if addition of infragenicular steady-state (SS) magnetic resonance angiography (MRA) to first-pass imaging improves diagnostic performance compared with first-pass imaging alone in patients with peripheral arterial disease (PAD) undergoing whole-body (WB) MRA. Twenty consecutive patients with PAD referred to digital-subtraction angiography (DSA) underwent WB-MRA. Using a bolus-chase technique, first-pass WB-MRA was performed from the supra-aortic vessels to the ankles. The blood-pool contrast agent gadofosveset trisodium was used at a dose of 0.03 mmol/kg body weight. Ten minutes after injection of the contrast agent, high-resolution (0.7-mm isotropic voxels) SS-MRA of the infragenicular arteriesmore » was performed. Using DSA as the 'gold standard,' sensitivities and specificities for detecting significant arterial stenoses ({>=}50% luminal narrowing) with first-pass WB-MRA, SS-MRA, and combined first-pass and SS-MRA were calculated. Kappa statistics were used to determine intermodality agreement between MRA and DSA. Overall sensitivity and specificity for detecting significant arterial stenoses with first-pass WB-MRA was 0.70 (95% confidence interval 0.61 to 0.78) and 0.97 (0.94 to 0.99), respectively. In first-pass WB-MRA, the lowest sensitivity was in the infragenicular region, with a value of 0.42 (0.23 to 0.63). Combined analysis of first-pass WB-MRA and SS-MRA increased sensitivity to 0.81 (0.60 to 0.93) in the infragenicular region, with specificity of 0.94 (0.88 to 0.97). Sensitivity and specificity for detecting significant arterial stenoses with isolated infragenicular SS-MRA was 0.47 (0.27 to 0.69) and 0.86 (0.78 to 0.91), respectively. Intermodality agreement between MRA and DSA in the infragenicular region was moderate for first-pass WB-MRA ({kappa} = 0.49), fair for SS-MRA ({kappa} = 0.31), and good for combined first-pass/SS-MRA ({kappa} = 0.71). Addition of infragenicular SS-MRA to first-pass WB MRA improves diagnostic performance.« less

  6. Image Registration of Cone-Beam Computer Tomography and Preprocedural Computer Tomography Aids in Localization of Adrenal Veins and Decreasing Radiation Dose in Adrenal Vein Sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Busser, Wendy M. H., E-mail: wendy.busser@radboudumc.nl; Arntz, Mark J.; Jenniskens, Sjoerd F. M.

    2015-08-15

    PurposeWe assessed whether image registration of cone-beam computed tomography (CT) (CBCT) and contrast-enhanced CT (CE-CT) images indicating the locations of the adrenal veins can aid in increasing the success rate of first-attempts adrenal vein sampling (AVS) and therefore decreasing patient radiation dose.Materials and Methods CBCT scans were acquired in the interventional suite (Philips Allura Xper FD20) and rigidly registered to the vertebra in previously acquired CE-CT. Adrenal vein locations were marked on the CT image and superimposed with live fluoroscopy and digital-subtraction angiography (DSA) to guide the AVS. Seventeen first attempts at AVS were performed with image registration and retrospectivelymore » compared with 15 first attempts without image registration performed earlier by the same 2 interventional radiologists. First-attempt AVS was considered successful when both adrenal vein samples showed representative cortisol levels. Sampling time, dose-area product (DAP), number of DSA runs, fluoroscopy time, and skin dose were recorded.ResultsWithout image registration, the first attempt at sampling was successful in 8 of 15 procedures indicating a success rate of 53.3 %. This increased to 76.5 % (13 of 17) by adding CBCT and CE-CT image registration to AVS procedures (p = 0.266). DAP values (p = 0.001) and DSA runs (p = 0.026) decreased significantly by adding image registration guidance. Sampling and fluoroscopy times and skin dose showed no significant changes.ConclusionGuidance based on registration of CBCT and previously acquired diagnostic CE-CT can aid in enhancing localization of the adrenal veins thereby increasing the success rate of first-attempt AVS with a significant decrease in the number of used DSA runs and, consequently, radiation dose required.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schernthaner, Ruediger E., E-mail: ruediger.schernthaner@meduniwien.ac.at; Haroun, Reham R., E-mail: rehamharoun1989@gmail.com; Duran, Rafael, E-mail: rafaelduran.md@gmail.com

    PurposeTo compare the visibility of liver metastases on dual-phase cone-beam CT (DP-CBCT) and digital subtraction angiography (DSA), with reference to preinterventional contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver.MethodsThis IRB-approved, retrospective study included 28 patients with neuroendocrine (NELM), colorectal (CRCLM), or sarcoma (SLM) liver metastases who underwent DP-CBCT during intra-arterial therapy (IAT) between 01/2010 and 10/2014. DP-CBCT was acquired after a single contrast agent injection in the tumor-feeding arteries at early and delayed arterial phases (EAP and DAP). The visibility of each lesion was graded by two radiologists in consensus on a three-rank scale (complete, partial, none) on DP-CBCT andmore » DSA images using CE-MRI as reference.Results47 NELM, 43 CRCLM, and 16 SLM were included. On DSA 85.1, 44.1, and 37.5 % of NELM, CRCLM, and SLM, were at least partially depicted, respectively. EAP-CBCT yielded significantly higher sensitivities of 88.3 and 87.5 % for CRCLM and SLM, respectively (p < 0.01), but not for NELM (89.4 %; p = 1.0). On DAP-CBCT all NELM, CRCLM, and SLM were visible (p < 0.001). Complete depiction was achieved on DSA for 59.6, 16.3, and 18.8 % of NELM, CRCLM, and SLM, respectively. The complete depiction rate on EAP-CBCT was significantly higher for CRCLM (46.5 %; p < 0.001), lower for NELM (40.4 %; p = 0.592), and similar for SLM (25 %, p = 0.399). On DAP-CBCT however, the highest rates of complete depiction were found—NELM (97.8 %; p = 0.008), CRCLM (95.3 %; p = 0.008), and SLM (100 %; p < 0.001).ConclusionDAP-CBCT substantially improved the visibility of liver metastases during IAT. Future studies need to evaluate the clinical impact.« less

  8. Ibrutinib suppresses alloantibody responses in a mouse model of allosensitization.

    PubMed

    Kim, Irene; Wu, Gordon; Chai, Ning-Ning; Klein, Andrew S; Jordan, Stanley

    2017-12-01

    Ibrutinib is a Bruton's tyrosine Kinase (BTK) antagonist that inhibits B cell receptor (BCR) signaling. Complete BTK deficiency is associated with absence of B-cells. Ibrutinb is currently approved by FDA for treatment of B-cell malignancies, including Waldenström macroglobulinaemia. We recently carried out studies to determine if ibrutinib could modify alloantibody responses. A mouse model of allogenic sensitization using a C57BL/6 mouse as the recipient of a skin allograft from an HLA-A2 transgenic mouse was utilized to examine the effects of ibrutinib on alloantibody responses and B cell effector functions. Donor-specific antibody (DSA) levels were measured in a flow-cytometric antibody binding assay. Splenic T and B cell subsets and plasma cells were analyzed in flow cytometry. Control mice developed peak levels of DSA IgM at day 14 PTx while the ibrutinib treated mice had significantly lower levels of DSA IgM (p=0.0047). Control mice developed HLA.A2-specific IgG antibodies at day 14 (230±60 MFI) and reached peak levels at day 21 (426±61 MFI). In contrast, mice in the treatment group had low levels of HLA.A2-specific IgG at day 14 (109±59 MFI, p=0.004) and day 21 (241±86 MFI, p=0.003). FACS analysis found a reduction of B220 + or CD19 + B cell population (p<0.05). In addition, ibrutinib attenuated recall DSA IgG responses to re-sensitization (p<0.05) and reduced CD38 + CD138 + plasma cells (p<0.05) in the spleens. Ibrutinib is effective in suppressing alloantibody responses through blocking BTK-mediated BCR signaling, leading to reduction of B cells and short-lived plasma cells in the spleens. Use of ibrutinib may provide benefits to HLA-sensitized transplant patients for alloantibody suppression. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Comparison of 3D TOF-MRA and 3D CE-MRA at 3T for imaging of intracranial aneurysms.

    PubMed

    Cirillo, Mario; Scomazzoni, Francesco; Cirillo, Luigi; Cadioli, Marcello; Simionato, Franco; Iadanza, Antonella; Kirchin, Miles; Righi, Claudio; Anzalone, Nicoletta

    2013-12-01

    To compare 3T elliptical-centric CE MRA with 3T TOF MRA for the detection and characterization of unruptured intracranial aneurysms (UIAs), by using digital subtracted angiography (DSA) as reference. Twenty-nine patients (12 male, 17 female; mean age: 62 years) with 41 aneurysms (34 saccular, 7 fusiform; mean diameter: 8.85 mm [range 2.0-26.4mm]) were evaluated with MRA at 3T each underwent 3D TOF-MRA examination without contrast and then a 3D contrast-enhanced (CE-MRA) examination with 0.1mmol/kg bodyweight gadobenate dimeglumine and k-space elliptic mapping (Contrast ENhanced Timing Robust Angiography [CENTRA]). Both TOF and CE-MRA images were used to evaluate morphologic features that impact the risk of rupture and the selection of a treatment. Almost half (20/41) of UIAs were located in the internal carotid artery, 7 in the anterior communicating artery, 9 in the middle cerebral artery and 4 in the vertebro-basilar arterial system. All patients also underwent DSA before or after the MR examination. The CE-MRA results were in all cases consistent with the DSA dataset. No differences were noted between 3D TOF-MRA and CE-MRA concerning the detection and location of the 41 aneurysms or visualization of the parental artery. Differences were apparent concerning the visualization of morphologic features, especially for large aneurysms (>13 mm). An irregular sac shape was demonstrated for 21 aneurysms on CE-MRA but only 13/21 aneurysms on 3D TOF-MRA. Likewise, CE-MRA permitted visualization of an aneurismal neck and calculation of the sac/neck ratio for all 34 aneurysms with a neck demonstrated at DSA. Conversely, a neck was visible for only 24/34 aneurysms at 3D TOF-MRA. 3D CE-MRA detected 15 aneurysms with branches originating from the sac and/or neck, whereas branches were recognized in only 12/15 aneurysms at 3D TOF-MRA. For evaluation of intracranial aneurysms at 3T, 3D CE-MRA is superior to 3D TOF-MRA for assessment of sac shape, detection of aneurysmal neck, and visualization of branches originating from the sac or neck itself, if the size of the aneurysm is greater than 13 mm. 3T 3D CE-MRA is as accurate and effective as DSA for the evaluation of UIAs. Copyright © 2013. Published by Elsevier Ireland Ltd.

  10. Signature detection and matching for document image retrieval.

    PubMed

    Zhu, Guangyu; Zheng, Yefeng; Doermann, David; Jaeger, Stefan

    2009-11-01

    As one of the most pervasive methods of individual identification and document authentication, signatures present convincing evidence and provide an important form of indexing for effective document image processing and retrieval in a broad range of applications. However, detection and segmentation of free-form objects such as signatures from clustered background is currently an open document analysis problem. In this paper, we focus on two fundamental problems in signature-based document image retrieval. First, we propose a novel multiscale approach to jointly detecting and segmenting signatures from document images. Rather than focusing on local features that typically have large variations, our approach captures the structural saliency using a signature production model and computes the dynamic curvature of 2D contour fragments over multiple scales. This detection framework is general and computationally tractable. Second, we treat the problem of signature retrieval in the unconstrained setting of translation, scale, and rotation invariant nonrigid shape matching. We propose two novel measures of shape dissimilarity based on anisotropic scaling and registration residual error and present a supervised learning framework for combining complementary shape information from different dissimilarity metrics using LDA. We quantitatively study state-of-the-art shape representations, shape matching algorithms, measures of dissimilarity, and the use of multiple instances as query in document image retrieval. We further demonstrate our matching techniques in offline signature verification. Extensive experiments using large real-world collections of English and Arabic machine-printed and handwritten documents demonstrate the excellent performance of our approaches.

  11. Directed self-assembly of mesoscopic components for led applications

    NASA Astrophysics Data System (ADS)

    Tkachenko, Anton

    Light-emitting diodes (LEDs) constitute a rapidly evolving and fast growing technology that promises to replace incandescent bulbs and compact fluorescent lights in many illumination applications. Large-area LED luminaires have a capability to transform lighting by providing a venue for development of smart lighting systems with additional benefits, such as visible light communications, sensing, health and productivity improvement through color temperature control, capability of creating "virtual sky" ceiling, and many others. The objective of this work is to explore directed self-assembly (DSA) approaches suitable for cost-effective assembly of large amount of LEDs and other mesoscopic (i.e. millimeter and sub-millimeter) electronic components and thus to enable manufacturing of smart lighting luminaires. Existing alternative approaches for assembly of semiconductor dies are examined including transfer printing, laser-assisted die transfer, and various directed self-assembly approaches using shape-recognition, magnetic and capillary forces, etc. After comparing their advantages and limitations, we developed two approaches to magnetic force-assisted DSA of LEDs on a large-area substrate in liquid and air medium. The first approach involves pick-up of buoyant and magnetic dies from the liquid surface onto the flexible substrate in a roll-to-roll process. The possibility of high-speed assembly of LED dies is demonstrated, but with a low yield due to the influence of the capillary force of the carrier liquid and the difficulty in ensuring reliable supply of dies to the assembly interface. To overcome the aforementioned challenges this process was modified to assemble the dies by sinking them onto the receiving substrate with a stencil mask on top, demonstrating LED assembly with a very low error rate but at a lower speed. A solder-assisted self-alignment is used to further improve placement precision and to ensure the proper orientation of the dies. The second approach involves self-assembly of dies in an air medium by levitating them in a periodic magnetic field. Using only vibration in z-direction with properly selected waveforms, both high-yield and high-speed DSA was demonstrated. Magnetostatic simulations were used to demonstrate scaling of DSA process with the die size while a model based on a 2D random walk was used to show how the assembly time scales with the number of dies and how this scaling law can be improved. These results indicate that this process can scale well both with the die size and with the number of assembled dies. Through this thesis work, it was demonstrated that assembly in liquid using ferromagnetic dies can be done either with high speed or with high yield, but not with both at the same time. DSA using diamagnetic levitation offers a way to achieve both through a careful design of magnetic field, thickness and quality of diamagnetic material (graphite) as well as proper selection of vibration pattern. This DSA process can enable large-area parallel assembly of millimeter and sub-millimeter components for manufacturing of LED panels, displays and microcell photovoltaics.

  12. WDS/DSA Certification - International collaboration for a trustworthy research data infrastructure

    NASA Astrophysics Data System (ADS)

    Mokrane, Mustapha; Hugo, Wim; Harrison, Sandy

    2016-04-01

    Today's research is international, transdisciplinary, and data-enabled, which requires scrupulous data stewardship, full and open access to data, and efficient collaboration and coordination. New expectations on researchers based on policies from governments and funders to share data fully, openly, and in a timely manner present significant challenges but are also opportunities to improve the quality and efficiency of research and its accountability to society. Researchers should be able to archive and disseminate data as required by many institutions or funders, and civil society to scrutinize datasets underlying public policies. Thus, the trustworthiness of data services must be verifiable. In addition, the need to integrate large and complex datasets across disciplines and domains with variable levels of maturity calls for greater coordination to achieve sufficient interoperability and sustainability. The World Data System (WDS) of the International Council for Science (ICSU) promotes long-term stewardship of, and universal and equitable access to, quality-assured scientific data and services across a range of disciplines in the natural and social sciences. WDS aims at coordinating and supporting trusted scientific data services for the provision, use, and preservation of relevant datasets to facilitate scientific research, in particular under the ICSU umbrella, while strengthening their links with the research community. WDS certifies its Members, holders and providers of data or data products, using internationally recognized standards. Certification of scientific data services is essential to ensure trustworthiness of the global research data infrastructure. It contributes to building a searchable, distributed, interoperable and sustainable research data infrastructure. Several certification standards have been developed over the last decade, such as the Network of Expertise in long-term Storage and Accessibility of Digital Resources in Germany (NESTOR) seal, German Institute for Standardization (DIN) standard 31644, Trustworthy Repositories Audit and Certification (TRAC) criteria and the International Organization for Standardization (ISO) standard 16363. In addition, the Data Seal of Approval (DSA) and WDS have set up core certification mechanisms for trusted digital repositories in 2009, which are increasingly recognized as de facto standards. While DSA emerged in Europe in the Humanities and Social Sciences, WDS started as an international initiative with historical roots in the Earth and Space Sciences. Their catalogues of requirements and review procedures are based on the same principles of openness, transparency. A unique feature of the DSA and WDS certification is that it strikes a balance between simplicity, robustness and the effort required to complete. A successful international cross-project collaboration was initiated between WDS and DSA under the umbrella of the Research Data Alliance (RDA), an international initiative started in 2013 to promote data interoperability which provided a useful and neutral forum. A joint working group was established in early 2014 to reconcile and simplify the array of certification options and improve and stimulate core certification for scientific data services. The outputs of this collaboration are a Catalogue of Common Requirements (https://goo.gl/LJZqDo) and a Catalogue of Common Procedures (https://goo.gl/vNR0q1) which will be implemented jointly by WDS and DSA.

  13. Cerebral angiography

    MedlinePlus

    ... Carotid angiogram; Cervicocerebral catheter-based angiography; Intra-arterial digital subtraction angiography; IADSA ... with the dye are seen. This is called digital subtraction angiography (DSA). After the x-rays are ...

  14. Ensemble analyses improve signatures of tumour hypoxia and reveal inter-platform differences

    PubMed Central

    2014-01-01

    Background The reproducibility of transcriptomic biomarkers across datasets remains poor, limiting clinical application. We and others have suggested that this is in-part caused by differential error-structure between datasets, and their incomplete removal by pre-processing algorithms. Methods To test this hypothesis, we systematically assessed the effects of pre-processing on biomarker classification using 24 different pre-processing methods and 15 distinct signatures of tumour hypoxia in 10 datasets (2,143 patients). Results We confirm strong pre-processing effects for all datasets and signatures, and find that these differ between microarray versions. Importantly, exploiting different pre-processing techniques in an ensemble technique improved classification for a majority of signatures. Conclusions Assessing biomarkers using an ensemble of pre-processing techniques shows clear value across multiple diseases, datasets and biomarkers. Importantly, ensemble classification improves biomarkers with initially good results but does not result in spuriously improved performance for poor biomarkers. While further research is required, this approach has the potential to become a standard for transcriptomic biomarkers. PMID:24902696

  15. Development of a Transient Acoustic Boundary Element Method to Predict the Noise Signature of Swimming Fish

    NASA Astrophysics Data System (ADS)

    Wagenhoffer, Nathan; Moored, Keith; Jaworski, Justin

    2015-11-01

    Animals have evolved flexible wings and fins to efficiently and quietly propel themselves through the air and water. The design of quiet and efficient bio-inspired propulsive concepts requires a rapid, unified computational framework that integrates three essential features: the fluid mechanics, the elastic structural response, and the noise generation. This study focuses on the development, validation, and demonstration of a transient, two-dimensional acoustic boundary element solver accelerated by a fast multipole algorithm. The resulting acoustic solver is used to characterize the acoustic signature produced by a vortex street advecting over a NACA 0012 airfoil, which is representative of vortex-body interactions that occur in schools of swimming fish. Both 2S and 2P canonical vortex streets generated by fish are investigated over the range of Strouhal number 0 . 2 < St < 0 . 4 , and the acoustic signature of the airfoil is quantified. This study provides the first estimate of the noise signature of a school of swimming fish. Lehigh University CORE Grant.

  16. Toward an Objective Enhanced-V Detection Algorithm

    NASA Technical Reports Server (NTRS)

    Moses, John F.; Brunner,Jason C.; Feltz, Wayne F.; Ackerman, Steven A.; Moses, John F.; Rabin, Robert M.

    2007-01-01

    The area of coldest cloud tops above thunderstorms sometimes has a distinct V or U shape. This pattern, often referred to as an "enhanced-V signature, has been observed to occur during and preceding severe weather. This study describes an algorithmic approach to objectively detect overshooting tops, temperature couplets, and enhanced-V features with observations from the Geostationary Operational Environmental Satellite and Low Earth Orbit data. The methodology consists of temperature, temperature difference, and distance thresholds for the overshooting top and temperature couplet detection parts of the algorithm and consists of cross correlation statistics of pixels for the enhanced-V detection part of the algorithm. The effectiveness of the overshooting top and temperature couplet detection components of the algorithm is examined using GOES and MODIS image data for case studies in the 2003-2006 seasons. The main goal is for the algorithm to be useful for operations with future sensors, such as GOES-R.

  17. Residual aneurysm after metal coils treatment detected by spectral CT

    PubMed Central

    Wang, Yang; Gao, Xiaolei; Lu, Aixun; Zhou, Zhengyang; Li, Baoxin

    2012-01-01

    Digital subtraction angiography (DSA) is currently the gold standard for diagnosing the residue or recurrence of aneurysm after treatment, especially in the presence of metal coils. However, DSA is an invasive procedure which may cause additional trauma and economic burden to patients. Spectral CT imaging, as a newly introduced CT imaging mode, produces monochromatic image sets that is able to reduce beam-hardening and other metal-related artifacts, and has found its use in several clinical applications including brain imaging to reduce beam-hardening artifacts. In this study, we describe a case of spectral CT imaging in follow-up of the metal coils treatment and detection of a small leaf of residual aneurysm after metal coils treatment. PMID:23256074

  18. Estimation of the physiological mechanical conditioning in vascular tissue engineering by a predictive fluid-structure interaction approach.

    PubMed

    Tresoldi, Claudia; Bianchi, Elena; Pellegata, Alessandro Filippo; Dubini, Gabriele; Mantero, Sara

    2017-08-01

    The in vitro replication of physiological mechanical conditioning through bioreactors plays a crucial role in the development of functional Small-Caliber Tissue-Engineered Blood Vessels. An in silico scaffold-specific model under pulsatile perfusion provided by a bioreactor was implemented using a fluid-structure interaction (FSI) approach for viscoelastic tubular scaffolds (e.g. decellularized swine arteries, DSA). Results of working pressures, circumferential deformations, and wall shear stress on DSA fell within the desired physiological range and indicated the ability of this model to correctly predict the mechanical conditioning acting on the cells-scaffold system. Consequently, the FSI model allowed us to a priori define the stimulation pattern, driving in vitro physiological maturation of scaffolds, especially with viscoelastic properties.

  19. Reliable classification of high explosive and chemical/biological artillery using acoustic sensors

    NASA Astrophysics Data System (ADS)

    Desai, Sachi V.; Hohil, Myron E.; Bass, Henry E.; Chambers, Jim

    2005-05-01

    Feature extraction methods based on the discrete wavelet transform and multiresolution analysis are used to develop a robust classification algorithm that reliably discriminates between conventional and simulated chemical/biological artillery rounds via acoustic signals produced during detonation utilizing a generic acoustic sensor. Based on the transient properties of the signature blast distinct characteristics arise within the different acoustic signatures because high explosive warheads emphasize concussive and shrapnel effects, while chemical/biological warheads are designed to disperse their contents over large areas, therefore employing a slower burning, less intense explosive to mix and spread their contents. The ensuing blast waves are readily characterized by variations in the corresponding peak pressure and rise time of the blast, differences in the ratio of positive pressure amplitude to the negative amplitude, and variations in the overall duration of the resulting waveform. Unique attributes can also be identified that depend upon the properties of the gun tube, projectile speed at the muzzle, and the explosive burn rates of the warhead. The algorithm enables robust classification of various airburst signatures using acoustics. It is capable of being integrated within an existing chemical/biological sensor, a stand-alone generic sensor, or a part of a disparate sensor suite. When emplaced in high-threat areas, this added capability would further provide field personal with advanced battlefield knowledge without the aide of so-called "sniffer" sensors that rely upon air particle information based on direct contact with possible contaminated air. In this work, the discrete wavelet transform is used to extract the predominant components of these characteristics from air burst signatures at ranges exceeding 2km while maintaining temporal sequence of the data to keep relevance to the transient differences of the airburst signatures. Highly reliable discrimination is achieved with a feedforward neural network classifier trained on a feature space derived from the distribution of wavelet coefficients and higher frequency details found within different levels of the multiresolution decomposition the neural network then is capable of classifying new airburst signatures as Chemical/Biological or High Explosive.

  20. Multi-Objective vs. Single Objective Calibration of a Hydrologic Model using Either Different Hydrologic Signatures or Complementary Data Sources

    NASA Astrophysics Data System (ADS)

    Mai, J.; Cuntz, M.; Zink, M.; Schaefer, D.; Thober, S.; Samaniego, L. E.; Shafii, M.; Tolson, B.

    2015-12-01

    Hydrologic models are traditionally calibrated against discharge. Recent studies have shown however, that only a few global model parameters are constrained using the integral discharge measurements. It is therefore advisable to use additional information to calibrate those models. Snow pack data, for example, could improve the parametrization of snow-related processes, which might be underrepresented when using only discharge. One common approach is to combine these multiple objectives into one single objective function and allow the use of a single-objective algorithm. Another strategy is to consider the different objectives separately and apply a Pareto-optimizing algorithm. Both methods are challenging in the choice of appropriate multiple objectives with either conflicting interests or the focus on different model processes. A first aim of this study is to compare the two approaches employing the mesoscale Hydrologic Model mHM at several distinct river basins over Europe and North America. This comparison will allow the identification of the single-objective solution on the Pareto front. It is elucidated if this position is determined by the weighting and scaling of the multiple objectives when combing them to the single objective. The principal second aim is to guide the selection of proper objectives employing sensitivity analyses. These analyses are used to determine if an additional information would help to constrain additional model parameters. The additional information are either multiple data sources or multiple signatures of one measurement. It is evaluated if specific discharge signatures can inform different parts of the hydrologic model. The results show that an appropriate selection of discharge signatures increased the number of constrained parameters by more than 50% compared to using only NSE of the discharge time series. It is further assessed if the use of these signatures impose conflicting objectives on the hydrologic model. The usage of signatures is furthermore contrasted to the use of additional observations such as soil moisture or snow height. The gain of using an auxiliary dataset is determined using the parametric sensitivity on the respective modeled variable.

Top