Effects of Greek orthodox christian church fasting on serum lipids and obesity
Sarri, Katerina O; Tzanakis, Nikolaos E; Linardakis, Manolis K; Mamalakis, George D; Kafatos, Anthony G
2003-01-01
Background No study to date has focused on the impact of Greek Orthodox Christian fasting on serum lipoproteins and obesity yet. Methods 120 Greek adults were followed longitudinally for one year. Sixty fasted regularly in all fasting periods (fasters) and 60 did not fast at all (controls). The three major fasting periods under study were: Christmas (40 days), Lent (48 days) and Assumption (August, 15 days). A total of 6 measurements were made during one year including pre- and end-fasting blood collection, serum lipoprotein analyses and anthropometric measurements. Results Statistically significant end-fasting total and LDL cholesterol differences were found in fasters. Fasters compared to controls presented 12.5% lower end-total cholesterol (p < 0.001), 15.9% lower end-LDL cholesterol (p < 0.001) and 1.5% lower end-BMI (p < 0.001). The end- LDL/HDL ratio was lower in fasters (6.5%, p < 0.05) while the change in end- HDL cholesterol in fasters (4.6% decline) was not significant. Similar results were found when the pre- and end-fasting values of fasters were compared. No change was found in control subjects. Conclusions Adherence to Greek Orthodox fasting periods contributes to a reduction in the blood lipid profile including a non-significant reduction in HDL cholesterol and possible impact on obesity. PMID:12753698
Mathieu, Chantal; Bode, Bruce W; Franek, Edward; Philis-Tsimikas, Athena; Rose, Ludger; Graungaard, Tina; Birk Østerskov, Anne; Russell-Jones, David
2018-05-01
To compare the safety and efficacy of fast-acting insulin aspart (faster aspart) with conventional insulin aspart (IAsp) in adults with type 1 diabetes (T1D). onset 1 was a randomized, multicentre, treat-to-target, phase III, 52-week (initial 26 weeks + additional 26 weeks) trial conducted at 165 sites across 9 countries. Adults with T1D were randomly allocated to double-blind mealtime faster aspart or IAsp, each with once- or twice-daily insulin detemir. The primary endpoint, change in glycated haemoglobin (HbA1c) from baseline after the initial 26 weeks, has been reported previously. In the present paper, we report data from the full 52-week study period. Between August 2013 and June 2015, 381 participants were assigned to double-blind faster aspart and 380 participants to IAsp. After 52 weeks, estimated mean changes from baseline in HbA1c levels were -0.08% (faster aspart) and +0.01% (IAsp); estimated treatment difference significantly favoured faster aspart (-0.10% [95% confidence interval {CI} -0.19;-0.00]; P = .0424). Changes from baseline in 1-hour postprandial plasma glucose (PPG) increment (meal test; faster aspart -1.05 mmol/L; IAsp -0.14 mmol/L) also significantly favoured faster aspart (estimated treatment difference -0.91 mmol/L [95% CI -1.40;-0.43]; -16.48 mg/dL [95% CI -25.17;-7.80]; P = .0002). There was no difference in overall severe or blood glucose-confirmed hypoglycaemic episodes or treatment-emergent adverse events between treatments. At 52 weeks, overall glycaemic control had significantly improved with faster aspart vs IAsp, consistent with the 26-week study findings. Achieving an insulin profile closer to physiological insulin secretion with faster aspart translates into lower PPG and HbA1c levels compared with those achieved with IAsp in people with T1D. © 2018 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.
Thirthalli, Jagadisha; Phutane, Vivek H; Muralidharan, Kesavan; Kumar, Channaveerachari Naveen; Munishwar, Bharat; Baspure, Prashant; Gangadhar, Bangalore N
2009-01-01
Electroconvulsive therapy (ECT) is generally recommended for treating catatonic schizophrenia. Non-catatonic schizophrenia patients also receive ECT. We compared the speed of response to ECT among patients with catatonic and other subtypes of schizophrenia. Consecutive schizophrenia patients referred for ECT within 3 months of starting antipsychotic treatment were studied (19 with catatonic and 34 with non-catatonic schizophrenia). Nurse's Observation Scale for Inpatient Evaluation (NOSIE-30) and Clinical Global Impression (CGI) were used to rate improvement. Referring psychiatrists stopped ECTs based on clinical impression of improvement. Total number of ECTs was taken as an indirect measure of speed of response. NOSIE-30 scores were compared using repeated measures analysis of variance. Catatonic schizophrenia patients required significantly fewer ECTs to achieve clinically significant improvement. There was a significant group x occasion effect in NOSIE scores, suggesting faster response to ECT in the catatonia group (F=41.6; P<0.001). Survival analysis suggested that patients with catatonic schizophrenia required significantly fewer ECTs (one less session on an average) to achieve clinical improvement (Log-rank statistic =5.31; P=0.02). Catatonic schizophrenia responds faster to ECT than non-catatonic schizophrenia. However, the magnitude of the difference is modest.
Faster-X evolution: Theory and evidence from Drosophila.
Charlesworth, Brian; Campos, José L; Jackson, Benjamin C
2018-02-12
A faster rate of adaptive evolution of X-linked genes compared with autosomal genes can be caused by the fixation of recessive or partially recessive advantageous mutations, due to the full expression of X-linked mutations in hemizygous males. Other processes, including recombination rate and mutation rate differences between X chromosomes and autosomes, may also cause faster evolution of X-linked genes. We review population genetics theory concerning the expected relative values of variability and rates of evolution of X-linked and autosomal DNA sequences. The theoretical predictions are compared with data from population genomic studies of several species of Drosophila. We conclude that there is evidence for adaptive faster-X evolution of several classes of functionally significant nucleotides. We also find evidence for potential differences in mutation rates between X-linked and autosomal genes, due to differences in mutational bias towards GC to AT mutations. Many aspects of the data are consistent with the male hemizygosity model, although not all possible confounding factors can be excluded. © 2018 John Wiley & Sons Ltd.
A systematic review of cognitive decline in dementia with Lewy bodies versus Alzheimer’s disease
2014-01-01
Introduction The aim of this review was to investigate whether there is a faster cognitive decline in dementia with Lewy bodies (DLB) than in Alzheimer’s disease (AD) over time. Methods PsycINFO and Medline were searched from 1946 to February 2013. A quality rating from 1 to 15 (best) was applied to the included studies. A quantitative meta-analysis was done on studies with mini mental state examination (MMSE) as the outcome measure. Results A total of 18 studies were included. Of these, six (36%) reported significant differences in the rate of cognitive decline. Three studies reported a faster cognitive decline on MMSE in patients with mixed DLB and AD compared to pure forms, whereas two studies reported a faster decline on delayed recall and recognition in AD and one in DLB on verbal fluency. Mean quality scores for studies that did or did not differ were not significantly different. Six studies reported MMSE scores and were included in the meta-analysis, which showed no significant difference in annual decline on MMSE between DLB (mean 3.4) and AD (mean 3.3). Conclusions Our findings do not support the hypothesis of a faster rate of cognitive decline in DLB compared to AD. Future studies should apply recent diagnostic criteria, as well as extensive diagnostic evaluation and ideally autopsy diagnosis. Studies with large enough samples, detailed cognitive tests, at least two years follow up and multivariate statistical analysis are also needed. PMID:25478024
Effect of Abiotic Factors on Degradation of Imidacloprid.
Mahapatra, Bibhab; Adak, Totan; Patil, Naveen K B; Pandi, G Guru P; Gowda, G Basana; Yadav, Manoj Kumar; Mohapatra, S D; Rath, P C; Munda, Sushmita; Jena, Mayabini
2017-10-01
The role of soil moisture, light and pH on imidacloprid dissipation was investigated. A high performance liquid chromatography (HPLC) based method was developed to quantify imidacloprid present in soil with a recovery of more than 82%. Rate of dissipation of imidacloprid from soil was faster in submerged condition compared to field capacity and air dried condition. Imidacloprid dissipated non-significantly between sterile and non-sterile soils, but at field capacity, the dissipation was faster in non-sterile soil compared to sterile soil after 60 days of incubation. Similarly, under submergence, the dissipation of imidacloprid was 66.2% and 79.8% of the initial in sterile and non-sterile soils, respectively. Imidacloprid was rather stable in acidic and neutral water but was prone to photo-degradation. Therefore, imidacloprid degradation will be faster under direct sunlight and at higher soil moisture.
A Comparison of Selective Pressures in Plant X-Linked and Autosomal Genes
Krasovec, Marc; Filatov, Dmitry A.
2018-01-01
Selection is expected to work differently in autosomal and X-linked genes because of their ploidy difference and the exposure of recessive X-linked mutations to haploid selection in males. However, it is not clear whether these expectations apply to recently evolved sex chromosomes, where many genes retain functional X- and Y-linked gametologs. We took advantage of the recently evolved sex chromosomes in the plant Silene latifolia and its closely related species to compare the selective pressures between hemizygous and non-hemizygous X-linked genes as well as between X-linked genes and autosomal genes. Our analysis, based on over 1000 genes, demonstrated that, similar to animals, X-linked genes in Silene evolve significantly faster than autosomal genes—the so-called faster-X effect. Contrary to expectations, faster-X divergence was detectable only for non-hemizygous X-linked genes. Our phylogeny-based analyses of selection revealed no evidence for faster adaptation in X-linked genes compared to autosomal genes. On the other hand, partial relaxation of purifying selection was apparent on the X-chromosome compared to the autosomes, consistent with a smaller genetic diversity in S. latifolia X-linked genes (πx = 0.016; πaut = 0.023). Thus, the faster-X divergence in S. latifolia appears to be a consequence of the smaller effective population size rather than of a faster adaptive evolution on the X-chromosome. We argue that this may be a general feature of “young” sex chromosomes, where the majority of X-linked genes are not hemizygous, preventing haploid selection in heterogametic sex. PMID:29751495
A Comparison of Selective Pressures in Plant X-Linked and Autosomal Genes.
Krasovec, Marc; Nevado, Bruno; Filatov, Dmitry A
2018-05-03
Selection is expected to work differently in autosomal and X-linked genes because of their ploidy difference and the exposure of recessive X-linked mutations to haploid selection in males. However, it is not clear whether these expectations apply to recently evolved sex chromosomes, where many genes retain functional X- and Y-linked gametologs. We took advantage of the recently evolved sex chromosomes in the plant Silene latifolia and its closely related species to compare the selective pressures between hemizygous and non-hemizygous X-linked genes as well as between X-linked genes and autosomal genes. Our analysis, based on over 1000 genes, demonstrated that, similar to animals, X-linked genes in Silene evolve significantly faster than autosomal genes—the so-called faster-X effect. Contrary to expectations, faster-X divergence was detectable only for non-hemizygous X-linked genes. Our phylogeny-based analyses of selection revealed no evidence for faster adaptation in X-linked genes compared to autosomal genes. On the other hand, partial relaxation of purifying selection was apparent on the X-chromosome compared to the autosomes, consistent with a smaller genetic diversity in S. latifolia X-linked genes (π x = 0.016; π aut = 0.023). Thus, the faster-X divergence in S. latifolia appears to be a consequence of the smaller effective population size rather than of a faster adaptive evolution on the X-chromosome. We argue that this may be a general feature of “young” sex chromosomes, where the majority of X-linked genes are not hemizygous, preventing haploid selection in heterogametic sex.
Dielectric Properties of Poly(ethylene oxide) from Molecular Dynamics Simulations
NASA Technical Reports Server (NTRS)
Smith, Grant D.
1994-01-01
The order, conformations and dynamics of poly(oxyethylene) (POE) melts have been investigated through molecular dynamics simulations. The potential energy functions were determined from detailed ab initio electronic structure calculations of the conformational energies of the model molecules 1,2-dimethoxyethane (DME) and diethylether. The x-ray structure factor for POE from simulation will be compared to experiment. In terms of conformation, simulations reveal that chains are extended in the melt relative to isolated chains due to the presence of strong intermolecular O...H interactions, which occur at the expense of intramolecular O...H interactions. Conformational dynamics about the C-C bond were found to be significantly faster than in polymethylene, while conformational dynamics about the C-O bond even faster than the C-C dynamics. The faster local dynamics in POE relative to polymethylene is consistent with C-13 NMR spin-lattice relaxation experiments. Conformational transitions showed significant second-neighbor correlation, as was found for polymethylene. This correlation of transitions with C-C neighbors was found to be reduced relative to C-O neighbors. Dielectric relaxation from simulation will also be compared with experiment.
Hartman, Marthinus Jacobus; Monnet, Eric; Kirberger, Robert Murco; Schoeman, Johan Petrus
2016-03-02
A prospective randomized study was used to compare surgery times for laparoscopic ovariectomy and salpingectomy in female African lion (Panthera leo) (n = 14) and cheetah (Acinonyx jubatus) (n = 20) and to compare the use of a multiple portal access system (MPAS) and single portal access system (SPAS) between groups. Two different portal techniques were used, namely MPAS (three separate ports) in lions and SPAS (SILS™ port) in cheetahs, using standard straight laparoscopic instruments. Portal access system and first ovary was not randomized. Five different surgery times were compared for the two different procedures as well as evaluating the use and application of MPAS and SPAS. Carbon dioxide volumes for lions were recorded. In adult lionesses operative time (OPT) (P = 0.016) and total surgical time (TST) (P = 0.032) were significantly shorter for salpingectomy compared to ovariectomy. Similarly in cheetahs OPT (P = 0.001) and TST (P = 0.005) were also shorter for salpingectomy compared to ovariectomy. In contrast, in lion cubs no difference was found in surgery times for ovariectomy and salpingectomy. Total unilateral procedure time was shorter than the respective bilateral time for both procedures (P = 0.019 and P = 0.001) respectively and unilateral salpingectomy was also faster than unilateral ovariectomy (P = 0.035) in cheetahs. Port placement time, suturing time and TST were significantly shorter for SPAS compared to MPAS (P = 0.008). There was, however, no difference in OPT between SPAS and MPAS. Instrument cluttering with SPAS was found to be negligible. There was no difference in mean volume CO2 required to complete ovariectomy in lions but the correlation between bodyweight and total volume of CO2 in lions was significant (rs = 0.867; P = 0.002). Laparoscopic salpingectomy was faster than ovariectomy in both adult lions and cheetahs. Using SPAS, both unilateral procedures were faster than bilateral procedures in cheetahs. Placement and suturing of SPAS in cheetahs was easier and faster compared to three separate ports in lions and lion cubs. The use of standard straight instruments during SPAS did not prolong surgery. Surgery was faster in cubs and CO2 required for laparoscopic sterilization in lions could be determined. Predictable surgery times and CO2 volumes will facilitate the accurate planning and execution of surgery in lions and cheetahs.
Effects of Different Lifting Cadences on Ground Reaction Forces during the Squat Exercise
NASA Technical Reports Server (NTRS)
Bentley, Jason R.; Amonette, William E.; Hagan, R. Donald
2008-01-01
The purpose of this investigation was to determine the effect of different cadences on the ground reaction force (GRF(sub R)) during the squat exercise. It is known that squats performed with greater acceleration will produce greater inertial forces; however, it is not well understood how different squat cadences affect GRF(sub R). It was hypothesized that faster squat cadences will result in greater peak GRF(sub R). METHODS: Six male subjects (30.8+/-4.4 y, 179.5+/-8.9 cm, 88.8+/-13.3 kg) with previous squat experience performed three sets of three squats using three different cadences (FC = 1 sec descent/1 sec ascent; MC = 3 sec descent/1 sec ascent; SC = 4 sec descent/2 sec ascent) with barbell mass equal to body mass. Ground reaction force was used to calculate inertial force trajectories of the body plus barbell (FI(sub system)). Forces were normalized to body mass. RESULTS: Peak GRF(sub R) and peak FI(sub system) were significantly higher in FC squats compared to MC (p=0.0002) and SC (p=0.0002). Range of GRF(sub R) and FI(sub system) were also significantly higher in FC compared to MC (p<0.05), and MC were significantly higher than SC (p<0.05). DISCUSSION: Faster squat cadences result in significantly greater peak GRF(sub R) due to the inertia of the system. GRF(sub R) was more dependent upon decent cadence than on ascent cadence. PRACTICAL APPLICATION: This study demonstrates that faster squat cadences produce greater ground reaction forces. Therefore, the use of faster squat cadences might enhance strength and power adaptations to long-term resistance exercise training. Key Words: velocity, weight training, resistive exercise
Srivastava, Sunil; Patil, Aditya Nanasaheb; Prakash, Chaitra; Kumari, Hiranmayi
2017-01-01
Objective: Despite the myriad options available, there is no universally accepted treatment for keloids. Our objective was to compare three regimens and establish superiority in terms of objective and subjective outcomes. Approach: In this randomized parallel group study, 60 patients were enrolled and randomly allocated to three groups. Patients received intralesional injections of triamcinolone acetonide (TAC) in Group TAC, 5-fluorouracil (5FU) in Group 5FU, and a combination in Group T + F every 3 weeks till 24 weeks or till the keloid resolved. Results: There was a reduction in all parameters at every successive assessment in all three groups. Improvement in terms of height, vascularity, and pliability was fastest with 5FU, TAC, and T + F group, respectively, which was statistically significant. Decrease in pigmentation was significantly faster with T+F. Reduction in pruritus, however, was significantly faster with 5FU than the other groups, but the difference in reduction of pain among the three groups was not significant. Telangiectasias and skin atrophy were seen most commonly in TAC group, while skin ulceration was a common problem in 5FU group. Conclusion: TAC, 5FU, and their combination are all effective in keloid scars. A combination of TAC +5FU seems to offer the balanced benefit of faster and more efficacious response with lesser adverse effects when compared to individual drugs. PMID:29098115
Auditory and visual interhemispheric communication in musicians and non-musicians.
Woelfle, Rebecca; Grahn, Jessica A
2013-01-01
The corpus callosum (CC) is a brain structure composed of axon fibres linking the right and left hemispheres. Musical training is associated with larger midsagittal cross-sectional area of the CC, suggesting that interhemispheric communication may be faster in musicians. Here we compared interhemispheric transmission times (ITTs) for musicians and non-musicians. ITT was measured by comparing simple reaction times to stimuli presented to the same hemisphere that controlled a button-press response (uncrossed reaction time), or to the contralateral hemisphere (crossed reaction time). Both visual and auditory stimuli were tested. We predicted that the crossed-uncrossed difference (CUD) for musicians would be smaller than for non-musicians as a result of faster interhemispheric transfer times. We did not expect a difference in CUDs between the visual and auditory modalities for either musicians or non-musicians, as previous work indicates that interhemispheric transfer may happen through the genu of the CC, which contains motor fibres rather than sensory fibres. There were no significant differences in CUDs between musicians and non-musicians. However, auditory CUDs were significantly smaller than visual CUDs. Although this auditory-visual difference was larger in musicians than non-musicians, the interaction between modality and musical training was not significant. Therefore, although musical training does not significantly affect ITT, the crossing of auditory information between hemispheres appears to be faster than visual information, perhaps because subcortical pathways play a greater role for auditory interhemispheric transfer.
Chung, Tae Nyoung; Kim, Sun Wook; You, Je Sung; Chung, Hyun Soo
2016-01-01
Objective Tube thoracostomy (TT) is a commonly performed intensive care procedure. Simulator training may be a good alternative method for TT training, compared with conventional methods such as apprenticeship and animal skills laboratory. However, there is insufficient evidence supporting use of a simulator. The aim of this study is to determine whether training with medical simulator is associated with faster TT process, compared to conventional training without simulator. Methods This is a simulation study. Eligible participants were emergency medicine residents with very few (≤3 times) TT experience. Participants were randomized to two groups: the conventional training group, and the simulator training group. While the simulator training group used the simulator to train TT, the conventional training group watched the instructor performing TT on a cadaver. After training, all participants performed a TT on a cadaver. The performance quality was measured as correct placement and time delay. Subjects were graded if they had difficulty on process. Results Estimated median procedure time was 228 seconds in the conventional training group and 75 seconds in the simulator training group, with statistical significance (P=0.040). The difficulty grading did not show any significant difference among groups (overall performance scale, 2 vs. 3; P=0.094). Conclusion Tube thoracostomy training with a medical simulator, when compared to no simulator training, is associated with a significantly faster procedure, when performed on a human cadaver. PMID:27752610
Rhinoscintigraphic analysis of nasal mucociliary function in patients with Bell's palsy.
Boynuegri, S; Ozer, S; Peksoy, I; Acikalin, A; Tuna, E Ü; Dursun, E; Eryilmaz, A
2016-01-01
Mucociliary transport (MCT) is an important defense mechanism of the respiratory tract. One of the major factors determining MCT is the ciliary activity of the respiratory epithelium. Rhinoscintigraphy is the most commonly used method for the analysis of mucociliary activity. The aim of this study was to investigate the effect of facial paralysis on the nasal mucociliary clearance. This study included 38 Bell's palsy patients as the study group and 10 subjects without any history of paranasal sinus disease or facial paralysis as the control group. A drop of technetium 99m-labeled macroaggregated albumin (Tc-99m MAA) was placed posterior to the head of the inferior turbinate and followed with a gamma camera. MCT rate was measured as the velocity of Tc-99m MAA drop. The mean MCT rate was 4.27 ± 0.76 millimeters per minute (mm/min) on 20 sides of 10 healthy controls, 4.11 ± 2.91 mm/min on the affected sides of the patients with Bell's palsy, and 6.03 ± 3.13 mm/min on the nonparalyzed sides of the patients. MCT rate was statistically significantly faster in the nonparalyzed side when compared to the paralyzed side in Bell's palsy patients (P = 0.001). MCT rates were not significantly different in the control group and paralyzed sides of the Bell's palsy patients (P = 0.810). The MCT rate was statistically significantly faster in the nonparalyzed sides of Bell's palsy patients when compared to the controls (P = 0.017). This study showed a faster MCT rate on the nonparalyzed side in Bell's palsy patients when compared to the paralyzed side and the control subjects. A compensatory mechanism could be the underlying reason for faster MCT on the nonparalyzed side. Further studies on larger patient groups are needed to investigate the effect of facial paralysis on the MCT and changes of facial nerve function on the opposite, nonparalyzed side of the face.
Auditory and Visual Interhemispheric Communication in Musicians and Non-Musicians
Woelfle, Rebecca; Grahn, Jessica A.
2013-01-01
The corpus callosum (CC) is a brain structure composed of axon fibres linking the right and left hemispheres. Musical training is associated with larger midsagittal cross-sectional area of the CC, suggesting that interhemispheric communication may be faster in musicians. Here we compared interhemispheric transmission times (ITTs) for musicians and non-musicians. ITT was measured by comparing simple reaction times to stimuli presented to the same hemisphere that controlled a button-press response (uncrossed reaction time), or to the contralateral hemisphere (crossed reaction time). Both visual and auditory stimuli were tested. We predicted that the crossed-uncrossed difference (CUD) for musicians would be smaller than for non-musicians as a result of faster interhemispheric transfer times. We did not expect a difference in CUDs between the visual and auditory modalities for either musicians or non-musicians, as previous work indicates that interhemispheric transfer may happen through the genu of the CC, which contains motor fibres rather than sensory fibres. There were no significant differences in CUDs between musicians and non-musicians. However, auditory CUDs were significantly smaller than visual CUDs. Although this auditory-visual difference was larger in musicians than non-musicians, the interaction between modality and musical training was not significant. Therefore, although musical training does not significantly affect ITT, the crossing of auditory information between hemispheres appears to be faster than visual information, perhaps because subcortical pathways play a greater role for auditory interhemispheric transfer. PMID:24386382
Breaking the Myth That Relay Swimming Is Faster Than Individual Swimming.
Skorski, Sabrina; Etxebarria, Naroa; Thompson, Kevin G
2016-04-01
To investigate if swimming performance is better in a relay race than in the corresponding individual race. The authors analyzed 166 elite male swimmers from 15 nations in the same competition (downloaded from www.swimrankings.net). Of 778 observed races, 144 were Olympic Games performances (2000, 2004, 2012), with the remaining 634 performed in national or international competitions. The races were 100-m (n = 436) and 200-m (n = 342) freestyle events. Relay performance times for the 2nd-4th swimmers were adjusted (+ 0.73 s) to allow for the "flying start." Without any adjustment, mean individual relay performances were significantly faster for the first 50 m and overall time in the 100-m events. Furthermore, the first 100 m of the 200-m relay was significantly faster (P > .001). During relays, swimmers competing in 1st position did not show any difference compared with their corresponding individual performance (P > .16). However, swimmers competing in 2nd-4th relay-team positions demonstrated significantly faster times in the 100-m (P < .001) and first half of the 200-m relays than in their individual events (P < .001, ES: 0.28-1.77). However, when finishing times for 2nd-4th relay team positions were adjusted for the flying start no differences were detected between relay and individual race performance for any event or split time (P > .17). Highly trained swimmers do not swim (or turn) faster in relay events than in their individual races. Relay exchange times account for the difference observed in individual vs relay performance.
Do Right- and Left-Handed Monkeys Differ on Cognitive Measures?
NASA Technical Reports Server (NTRS)
Hopkins, William D.; Washburn, David A.
1994-01-01
Twelve left- and 14 right-handed monkeys were compared on 6 measures of cognitive performance (2 maze-solving tasks, matching-to-sample, delayed matching-to-sample, delayed response using spatial cues, and delayed response using form cues). The dependent variable was trials-to-training criterion for each of the 6 tasks. Significant differences were found between left- and right-handed monkeys on the 2 versions of the delayed response task. Right-handed monkeys reached criterion significantly faster on the form cue version of the task, whereas left-handed monkeys reached criterion significantly faster on delayed response for spatial position (p less than .05). The results suggest that sensitive hand preference measures of laterality can reveal differences in cognitive performance, which in turn may reflect underlying laterality in functional organization of the nervous system.
The simplest chronoscope II: reaction time measured by meterstick versus machine.
Montare, Alberto
2010-12-01
Visual simple reaction time (SRT) scores measured in 31 college students of both sexes by use of the simplest chronoscope methodology (meterstick SRT) were compared to scores obtained by use of an electromechanical multi-choice reaction timer (machine SRT). Four hypotheses were tested. Results indicated that the previous mean value of meterstick SRT was replicated; meterstick SRT was significantly faster than long-standing population estimates of mean SRT; and machine SRT was significantly slower than the same long-standing mean SRT estimates for the population. Also, the mean meterstick SRT of 181 msec. was significantly faster than the mean machine SRT of 294 msec. It was theorized that differential visual information processing occurred such that the dorsal visual stream subserved meterstick SRT; whereas the ventral visual stream subserved machine SRT.
[A comparison between adults and children tonsillectomy with monopolar electrocautery].
Ao, Min; Deng, Jie; Gao, Lei; He, Gang
2015-02-01
Tonsillectomy is one of the most frequently applied operations in the ENT practice. This prospective study compared intraoperative records and postoperative clinical outcomes between adults and children patients following monopolar electrocautery tonsillectomy. Forty adult patients and Forty children patients with histories of recurrent tonsillitis or hypertrophic tonsillitis were enrolled. Intraoperative parameters and postoperative outcomes were compared. Children tonsillectomy with monopolar electrocautery was significantly faster to perform (P < 0.05), and produced significantly less intraoperative blood loss (P < 0.05), and faster to return to commencement of a regular diet (P < 0.05) than adults. Children tonsillectomy endured less postopera- tive pain within a week (P > 0.05) than adults, but there was no significant difference in pain on the 14th postoperative day in two groups. There was no obvious postoperative hemorrhage in two groups. There was no significant difference in postoperative tonsillar fossa healing and postoperative temperature between the groups. Children and adults tonsillectomy with monopolar electrocautery had clinical characteristics respectively. Monopolar electrocautery tonsillectomy was safe and operated easily in both two groups.
Is the Self Always Better than a Friend? Self-Face Recognition in Christians and Atheists
Ma, Yina; Han, Shihui
2012-01-01
Early behavioral studies found that human adults responded faster to their own faces than faces of familiar others or strangers, a finding referred to as self-face advantage. Recent research suggests that the self-face advantage is mediated by implicit positive association with the self and is influenced by sociocultural experience. The current study investigated whether and how Christian belief and practice affect the processing of self-face in a Chinese population. Christian and Atheist participants were recruited for an implicit association test (IAT) in Experiment 1 and a face-owner identification task in Experiment 2. Experiment 1 found that atheists responded faster to self-face when it shared the same response key with positive compared to negative trait adjectives. This IAT effect, however, was significantly reduced in Christians. Experiment 2 found that atheists responded faster to self-face compared to a friend’s face, but this self-face advantage was significantly reduced in Christians. Hierarchical regression analyses further showed that the IAT effect positively predicted self-face advantage in atheists but not in Christians. Our findings suggest that Christian belief and practice may weaken implicit positive association with the self and thus decrease the advantage of the self over a friend during face recognition in the believers. PMID:22662231
Is the self always better than a friend? Self-face recognition in Christians and atheists.
Ma, Yina; Han, Shihui
2012-01-01
Early behavioral studies found that human adults responded faster to their own faces than faces of familiar others or strangers, a finding referred to as self-face advantage. Recent research suggests that the self-face advantage is mediated by implicit positive association with the self and is influenced by sociocultural experience. The current study investigated whether and how Christian belief and practice affect the processing of self-face in a Chinese population. Christian and Atheist participants were recruited for an implicit association test (IAT) in Experiment 1 and a face-owner identification task in Experiment 2. Experiment 1 found that atheists responded faster to self-face when it shared the same response key with positive compared to negative trait adjectives. This IAT effect, however, was significantly reduced in Christians. Experiment 2 found that atheists responded faster to self-face compared to a friend's face, but this self-face advantage was significantly reduced in Christians. Hierarchical regression analyses further showed that the IAT effect positively predicted self-face advantage in atheists but not in Christians. Our findings suggest that Christian belief and practice may weaken implicit positive association with the self and thus decrease the advantage of the self over a friend during face recognition in the believers.
Smith, Beth A.; Kubo, Masayoshi; Ulrich, Beverly D.
2012-01-01
The combined effects of ligamentous laxity, hypotonia, and decrements associated with aging lead to stability-enhancing foot placement adaptations during routine overground walking at a younger age in adults with Down syndrome (DS) compared to their peers with typical development (TD). Our purpose here was to examine real-time adaptations in older adults with DS by testing their responses to walking on a treadmill at their preferred speed and at speeds slower and faster than preferred. We found that older adults with DS were able to adapt their gait to slower and faster than preferred treadmill speeds; however, they maintained their stability-enhancing foot placements at all speeds compared to their peers with TD. All adults adapted their gait patterns similarly in response to faster and slower than preferred treadmill-walking speeds. They increased stride frequency and stride length, maintained step width, and decreased percent stance as treadmill speed increased. Older adults with DS, however, adjusted their stride frequencies significantly less than their peers with TD. Our results show that older adults with DS have the capacity to adapt their gait parameters in response to different walking speeds while also supporting the need for intervention to increase gait stability. PMID:22693497
Fujibayashi, Nobuaki; Otsuka, Mitsuo; Yoshioka, Shinsuke; Isaka, Tadao
2017-10-24
The present study aims to cross-sectionally clarify the characteristics of the motions of an inverted pendulum model, a stance leg, a swing leg and arms in different triple-jumping techniques to understand whether or not hop displacement is relatively longer rather than step and jump displacements. Eighteen male athletes performed the triple jump with a full run-up. Based on the technique of the jumpers, they were classified as hop-dominated (n = 10) or balance (n = 8) jumpers. The kinematic data were calculated using motion capture and compared between the two techniques using the inverted pendulum model. The hop-dominated jumpers had a significantly longer hop displacement and faster vertical centre-of-mass (COM) velocity of their whole body at hop take-off, which was generated by faster rotation behaviours of inverted pendulum model and faster swinging behaviours of arms. Conversely, balance jumpers had a significantly longer jump displacement and faster horizontal COM velocity of their whole body at take-off, which was generated by a stiffer inverted pendulum model and stance leg. The results demonstrate that hop-dominated and balance jumpers enhanced each dominated-jump displacement using different swing- and stance-leg motions. This information may help to enhance the actual displacement of triple jumpers using different jumping techniques.
Ratite oils promote keratinocyte cell growth and inhibit leukocyte activation
Bennett, Darin C.; Leung, Gigi; Wang, Eddy; Ma, Sam; Lo, Blanche K. K.; McElwee, Kevin J.; Cheng, Kimberly M.
2015-01-01
Traditionally, native Australian aborigines have used emu oil for the treatment of inflammation and to accelerate wound healing. Studies on mice suggest that topically applied emu oil may have anti-inflammatory properties and may promote wound healing. We investigated the effects of ratite oils (6 emu, 3 ostrich, 1 rhea) on immortalized human keratinocytes (HaCaT cells) in vitro by culturing the cells in media with oil concentrations of 0%, 0.5%, and 1.0%. Peking duck, tea tree, and olive oils were used as comparative controls. The same oils at 0.5% concentration were evaluated for their influence on peripheral blood mononuclear cell (PBMC) survival over 48 hr and their ability to inhibit IFNγ production in PBMCs activated by phytohemagglutinin (PHA) in ELISpot assays. Compared to no oil control, significantly shorter population doubling time durations were observed for HaCaT cells cultured in emu oil (1.51 × faster), ostrich oil (1.46 × faster), and rhea oil (1.64 × faster). Tea tree oil demonstrated significant antiproliferative activity and olive oil significantly prolonged (1.35 × slower) cell population doubling time. In contrast, almost all oils, particularly tea tree oil, significantly reduced PBMC viability. Different oils had different levels of inhibitory effect on IFNγ production with individual emu, ostrich, rhea, and duck oil samples conferring full inhibition. This preliminary investigation suggests that emu oil might promote wound healing by accelerating the growth rate of keratinocytes. Combined with anti-inflammatory properties, ratite oil may serve as a useful component in bandages and ointments for the treatment of wounds and inflammatory skin conditions. PMID:26217022
The African disability scooter: efficiency testing in paediatric amputees in Malawi
Beckles, Verona; McCahill, Jennifer L.; Stebbins, Julie; Mkandawire, Nyengo; Church, John C. T.; Lavy, Chris
2016-01-01
Abstract Purpose: The African Disability Scooter (ADS) was developed for lower limb amputees, to improve mobility and provide access to different terrains. The aim of this study was to test the efficiency of the ADS in Africa over different terrains. Method: Eight subjects with a mean age of 12 years participated. Energy expenditure and speed were calculated over different terrains using the ADS, a prosthetic limb, and crutches. Repeated testing was completed on different days to assess learning effect. Results: Speed was significantly faster with the ADS on a level surface compared to crutch walking. This difference was maintained when using the scooter on rough terrain. Oxygen cost was halved with the scooter on level ground compared to crutch walking. There were no significant differences in oxygen consumption or heart rate. There were significant differences in oxygen cost and speed between days using the scooter over level ground, suggesting the presence of a learning effect. Conclusions: This study demonstrates that the ADS is faster and more energy efficient than crutch walking in young individuals with amputations, and should be considered as an alternative to a prosthesis where this is not available. The presence of a learning effect suggests supervision and training is required when the scooter is first issued.Implications for RehabilitationThe African Disability Scooter:is faster than crutch walking in amputees;is more energy efficient than walking with crutches;supervised use is needed when learning to use the device;is a good alternative/adjunct for mobility. PMID:25316033
Differences in In Vitro Disintegration Time among Canadian Brand and Generic Bisphosphonates
Olszynski, Wojciech P.; Adachi, Jonathan D.; Davison, K. Shawn
2014-01-01
The objective of this study was to compare the disintegration times among Canadian-marketed brand (alendronate 70 mg, alendronate 70 mg plus vitamin D 5600 IU, and risedronate 35 mg) and generic (Novo-alendronate 70 mg and Apo-alendronate 70 mg) once-weekly dosed bisphosphonates. All disintegration tests were performed with a Vanderkamp Disintegration Tester. Disintegration was deemed to have occurred when no residue of the tablet, except fragments of insoluble coating or capsule shell, was visible. Eighteen to 20 samples were tested for each bisphosphonate group. The mean (±standard deviation) disintegration times were significantly (P < 0.05) faster for Apo-alendronate (26 ± 5.6 seconds) and Novo-alendronate (13 ± 1.1 seconds) as compared to brand alendronate (147 ± 50.5 seconds), brand alendronate plus vitamin D (378 ± 60.5 seconds), or brand risedronate (101 ± 20.6 seconds). The significantly faster disintegration of the generic tablets as compared to the brand bisphosphonates may have concerning safety and effectiveness implications for patients administering these therapies. PMID:25349772
Differences in In Vitro Disintegration Time among Canadian Brand and Generic Bisphosphonates.
Olszynski, Wojciech P; Adachi, Jonathan D; Davison, K Shawn
2014-01-01
The objective of this study was to compare the disintegration times among Canadian-marketed brand (alendronate 70 mg, alendronate 70 mg plus vitamin D 5600 IU, and risedronate 35 mg) and generic (Novo-alendronate 70 mg and Apo-alendronate 70 mg) once-weekly dosed bisphosphonates. All disintegration tests were performed with a Vanderkamp Disintegration Tester. Disintegration was deemed to have occurred when no residue of the tablet, except fragments of insoluble coating or capsule shell, was visible. Eighteen to 20 samples were tested for each bisphosphonate group. The mean (±standard deviation) disintegration times were significantly (P < 0.05) faster for Apo-alendronate (26 ± 5.6 seconds) and Novo-alendronate (13 ± 1.1 seconds) as compared to brand alendronate (147 ± 50.5 seconds), brand alendronate plus vitamin D (378 ± 60.5 seconds), or brand risedronate (101 ± 20.6 seconds). The significantly faster disintegration of the generic tablets as compared to the brand bisphosphonates may have concerning safety and effectiveness implications for patients administering these therapies.
Causer, Joe; Harvey, Adrian; Snelgrove, Ryan; Arsenault, Gina; Vickers, Joan N
2014-08-01
We examined the effectiveness of technical training (TT) and quiet eye training (QE) on the performance of one-handed square knot tying in surgical residents. Twenty surgical residents were randomly assigned to the 2 groups and completed pretest, training, retention, and transfer tests. Participants wore a mobile eye tracker that simultaneously recorded their gaze and hand movements. Dependent variables were knot tying performance (%), QE duration (%), number of fixations, total movement time (s), and hand movement phase time (s). The QE training group had significantly higher performance scores, a longer QE duration, fewer fixations, faster total knot tying times, and faster movement phase times compared with the TT group. The QE group maintained performance in the transfer test, whereas the TT group significantly decreased performance from retention to transfer. QE training significantly improved learning, retention, and transfer of surgical knot tying compared with a traditional technical approach. Both performance effectiveness (performance outcome) and movement efficiency (hand movement times) were improved using QE modeling, instruction, and feedback. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Maciá, Silvia; Robinson, Michael P.
2008-12-01
The sea urchin Tripneustes ventricosus is a common, yet relatively poorly known, grazer of seagrass beds and coral reefs throughout the Caribbean. We compared the size and abundance of urchins between adjacent seagrass and coral reef habitats (where macroalgae are the dominant primary producers). We also conducted a laboratory experiment comparing the growth rate of juvenile urchins fed a diet of either macroalgae or seagrass. Reef urchins had significantly larger test diameter than those in the seagrass on some sampling dates. This size difference may be at least partially explained by diet, because laboratory-reared urchins fed macroalgae grew significantly faster than those fed seagrass. The seagrass population, however, was stable over time, whereas the reef population exhibited strong fluctuations in abundance. Overall, our study indicates that both the seagrass and coral reef habitats are capable of supporting healthy, reproductive populations of T. ventricosus. Each, however, appears to offer a distinct advantage: faster growth on the reef and greater population stability in the seagrass.
Ratite oils promote keratinocyte cell growth and inhibit leukocyte activation.
Bennett, Darin C; Leung, Gigi; Wang, Eddy; Ma, Sam; Lo, Blanche K K; McElwee, Kevin J; Cheng, Kimberly M
2015-09-01
Traditionally, native Australian aborigines have used emu oil for the treatment of inflammation and to accelerate wound healing. Studies on mice suggest that topically applied emu oil may have anti-inflammatory properties and may promote wound healing. We investigated the effects of ratite oils (6 emu, 3 ostrich, 1 rhea) on immortalized human keratinocytes (HaCaT cells) in vitro by culturing the cells in media with oil concentrations of 0%, 0.5%, and 1.0%. Peking duck, tea tree, and olive oils were used as comparative controls. The same oils at 0.5% concentration were evaluated for their influence on peripheral blood mononuclear cell (PBMC) survival over 48 hr and their ability to inhibit IFNγ production in PBMCs activated by phytohemagglutinin (PHA) in ELISpot assays. Compared to no oil control, significantly shorter population doubling time durations were observed for HaCaT cells cultured in emu oil (1.51×faster), ostrich oil (1.46×faster), and rhea oil (1.64×faster). Tea tree oil demonstrated significant antiproliferative activity and olive oil significantly prolonged (1.35×slower) cell population doubling time. In contrast, almost all oils, particularly tea tree oil, significantly reduced PBMC viability. Different oils had different levels of inhibitory effect on IFNγ production with individual emu, ostrich, rhea, and duck oil samples conferring full inhibition. This preliminary investigation suggests that emu oil might promote wound healing by accelerating the growth rate of keratinocytes. Combined with anti-inflammatory properties, ratite oil may serve as a useful component in bandages and ointments for the treatment of wounds and inflammatory skin conditions. © 2015 Poultry Science Association Inc.
Strength, speed and power characteristics of elite rugby league players.
de Lacey, James; Brughelli, Matt E; McGuigan, Michael R; Hansen, Keir T
2014-08-01
The purpose of this article was to compare strength, speed, and power characteristics between playing position (forwards and backs) in elite rugby league players. A total of 39 first team players (height, 183.8 ± 5.95 cm; body mass, 100.3 ± 10.7 kg; age, 24 ± 3 years) from a National Rugby League club participated in this study. Testing included 10-, 40-m sprint times, sprint mechanics on an instrumented nonmotorized treadmill, and concentric isokinetic hip and knee extension and flexion. Backs, observed to have significantly (p ≤ 0.05) lighter body mass (effect size [ES] = 0.98), were significantly faster (10-m ES = 1.26; 40-m ES = 1.61) and produced significantly greater relative horizontal force and power (ES = 0.87 and 1.04) compared with forwards. However, no significant differences were found between forwards and backs during relative isokinetic knee extension, knee flexion, relative isokinetic hip extension, flexion, prowler sprints, sprint velocity, contact time, or flight time. The findings demonstrate that backs have similar relative strength in comparison with forwards, but run faster overground and produce significantly greater relative horizontal force and power when sprinting on a nonmotorized instrumented treadmill. Developing force and power in the horizontal direction may be beneficial for improving sprint performance in professional rugby league players.
A new, easy-to-make pectin-honey hydrogel enhances wound healing in rats.
Giusto, Gessica; Vercelli, Cristina; Comino, Francesco; Caramello, Vittorio; Tursi, Massimiliano; Gandini, Marco
2017-05-16
Honey, alone or in combination, has been used for wound healing since ancient times and has reemerged as a topic of interest in the last decade. Pectin has recently been investigated for its use in various biomedical applications such as drug delivery, skin protection, and scaffolding for cells. The aim of the present study was to develop and evaluate a pectin-honey hydrogel (PHH) as a wound healing membrane and to compare this dressing to liquid honey. Thirty-six adult male Sprague-Dawley rats were anesthetized and a 2 × 2 cm excisional wound was created on the dorsum. Animals were randomly assigned to four groups (PHH, LH, Pec, and C): in the PHH group, the pectin-honey hydrogel was applied under a bandage on the wound; in the LH group, liquid Manuka honey was applied; in the Pec group, pectin hydrogel was applied (Pec); and in the C group, only bandage was applied to the wound. Images of the wound were taken at defined time points, and the wound area reduction rate was calculated and compared between groups. The wound area reduction rate was faster in the PHH, LH, and Pec groups compared to the control group and was significantly faster in the PHH group. Surprisingly, the Pec group exhibited faster wound healing than the LH group, but this effect was not statistically significant. This is the first study using pectin in combination with honey to produce biomedical hydrogels for wound treatment. The results indicate that the use of PHH is effective for promoting and accelerating wound healing.
Liu, Hong; Yin, Hui-fang; Wu, Da-xing; Xu, Shu-jing
2014-01-01
Dysfunctional cognitive processing and abnormal brain activation in response to emotional stimuli have long been recognized as core features of the major depressive disorder (MDD). The aim of this study was to examine how Chinese patients with MDD process Chinese emotional words presented to either the left (LH) or right hemisphere (RH). Reaction time (RT) and the late positive component of the event-related potential were measured while subjects judged the valence (positive or negative) of emotional words written in Chinese. Compared to healthy controls, patients with MDD exhibited slower RTs in response to negative words. In all subjects, the RTs in response to negative words were significantly faster than RTs in response to positive words presented to the LH, as well as significantly faster than responses to negative words presented to the RH. Compared to healthy controls, MDD patients exhibited reduced activation of the central and left regions of the brain in response to both negative and positive words. In healthy controls, the posterior brain areas were more active than the anterior brain areas when responding to negative words. All individuals showed faster RTs in response to negative words compared to positive words. In addition, MDD patients showed lateralization of brain activity in response to emotional words, whereas healthy individuals did not show this lateralization. Posterior brain areas appear to play an especially important role in discriminating and experiencing negative emotional words. This study provides further evidence in support of the negative bias hypothesis and the emotional processing theory.
Burnfield, Judith M; Eberly, Valerie J; Gronely, Joanne K; Perry, Jacquelin; Yule, William Jared; Mulroy, Sara J
2012-03-01
Microprocessor controlled prosthetic knees (MPK) offer opportunities for improved walking stability and function, but some devices' swing phase features may exceed needs of users with invariable cadence. One MPK offers computerized control of only stance (C-Leg Compact). To assess Medicare Functional Classification Level K2 walkers' ramp negotiation performance, function and balance while using a non-MPK (NMPK) compared to the C-Leg Compact. Crossover. Gait while ascending and descending a ramp (stride characteristics, kinematics, electromyography) and function were assessed in participant's existing NMPK and again in the C-Leg Compact following accommodation. Ramp ascent and descent were markedly faster in the C-Leg Compact compared to the NMPK (p ≤ 0.006), owing to increases in stride length (p ≤ 0.020) and cadence (p ≤ 0.020). Residual limb peak knee flexion and ankle dorsiflexion were significantly greater (12.9° and 4.9° more, respectively) during single limb support while using the C-Leg Compact to descend ramps. Electromyography (mean, peak) did not differ significantly between prosthesis. Function improved in the C-Leg Compact as evidenced by a significantly faster Timed Up and Go and higher functional questionnaire scores. Transfemoral K2 walkers exhibited significantly improved function and balance while using the stance-phase only MPK compared to their traditional NMPK.
Ahmad, Asima K; Kao, Chia-Ning; Quinn, Molly; Lenhart, Nikolaus; Rosen, Mitchell; Cedars, Marcelle I; Huddleston, Heather
2018-03-01
To estimate rates of ovarian aging in polycystic ovary syndrome (PCOS) subjects versus a community control population. Longitudinal. Tertiary academic center. PCOS subjects diagnosed according to the 2004 Rotterdam criteria were systematically enrolled in a PCOS cohort study. The comparison control subjects were from the Ovarian Aging study, a prospective longitudinal study of ovarian aging in healthy women with regular menstrual cycles. Clinical data collection over two study visits. Antral follicle count (AFC), ovarian volume (OV), and antimüllerian hormone level (AMH). PCOS subjects were found to have higher baseline values for all ovarian reserve markers compared with control subjects. Univariate models indicated that, compared with control subjects, PCOS patients experienced significantly faster rates of decline for both AFC and AMH. Change in OV did not differ significantly. To account for potential confounder effects, multiple analysis of covariance models were evaluated for the best fit, considering age, body mass index, and baseline ovarian reserve markers. Adjusted models demonstrated that PCOS patients do not experience a significant difference in AFC decline compared with control subjects, but they do experience a faster rate of decline in AMH (P<.01) and slower rate of decline in OV (P<.01). Ovarian aging in PCOS is characterized by a more rapid decline in AMH and a slower decline in OV compared with control subjects. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Harland, S; Legge, G E; Luebker, A
1998-03-01
Most people with low vision need magnification to read. Page navigation is the process of moving a magnifier during reading. Modern electronic technology can provide many alternatives for navigating through text. This study compared reading speeds for four methods of displaying text. The four methods varied in their page-navigation demands. The closed-circuit television (CCTV) and MOUSE methods involved manual navigation. The DRIFT method (horizontally drifting text) involved no manual navigation, but did involve both smooth-pursuit and saccadic eye movements. The rapid serial visual presentation (RSVP) method involved no manual navigation, and relatively few eye movements. There were 7 normal subjects and 12 low-vision subjects (7 with central-field loss, CFL group, and 5 with central fields intact, CFI group). The subjects read 70-word passages at speeds that yielded good comprehension. Taking the CCTV reading speed as a benchmark, neither the normal nor low-vision subjects had significantly different speeds with the MOUSE method. As expected from the reduced navigational demands, normal subjects read faster with the DRIFT method (85% faster) and the RSVP method (169%). The CFI group read significantly faster with DRIFT (43%) and RSVP (38%). The CFL group showed no significant differences in reading speed for the four methods.
Congruent bodily arousal promotes the constructive recognition of emotional words.
Kever, Anne; Grynberg, Delphine; Vermeulen, Nicolas
2017-08-01
Considerable research has shown that bodily states shape affect and cognition. Here, we examined whether transient states of bodily arousal influence the categorization speed of high arousal, low arousal, and neutral words. Participants realized two blocks of a constructive recognition task, once after a cycling session (increased arousal), and once after a relaxation session (reduced arousal). Results revealed overall faster response times for high arousal compared to low arousal words, and for positive compared to negative words. Importantly, low arousal words were categorized significantly faster after the relaxation than after the cycling, suggesting that a decrease in bodily arousal promotes the recognition of stimuli matching one's current arousal state. These findings highlight the importance of the arousal dimension in emotional processing, and suggest the presence of arousal-congruency effects. Copyright © 2017 Elsevier Inc. All rights reserved.
Batting cage performance of wood and nonwood youth baseball bats.
Crisco, Joseph J; Rainbow, Michael J; Schwartz, Joel B; Wilcox, Bethany J
2014-04-01
The purpose of this study was to examine the batting cage performance of wood and nonwood baseball bats used at the youth level. Three wood and ten nonwood bats were swung by 22 male players (13 to 18 years old) in a batting cage equipped with a 3-dimensional motion capture (300 Hz) system. Batted ball speeds were compared using a one-way ANOVA and bat swing speeds were analyzed as a function of bat moment of inertia by linear regression. Batted ball speeds were significantly faster for three nonwood bat models (P<.001), significantly slower for one nonwood model, and not different for six nonwood bats when compared with wood bats. Bat impact speed significantly (P<.05) decreased with increasing bat moment of inertia for the 13-, 14-, and 15-year-old groups, but not for the other age groups. Ball-bat coefficients of restitution (BBCOR) for all nonwood were greater than for wood, but this factor alone did not correlate with bat performance. Our findings indicate that increases in BBCOR and swing speed were not associated with faster batted ball speeds for the bats studied whose moment of inertia was substantially less than that of a wood bat of similar length.
Jelicic Kadic, Antonia; Vucic, Katarina; Dosenovic, Svjetlana; Sapunar, Damir; Puljak, Livia
2016-06-01
To compare speed and accuracy of graphical data extraction using manual estimation and open source software. Data points from eligible graphs/figures published in randomized controlled trials (RCTs) from 2009 to 2014 were extracted by two authors independently, both by manual estimation and with the Plot Digitizer, open source software. Corresponding authors of each RCT were contacted up to four times via e-mail to obtain exact numbers that were used to create graphs. Accuracy of each method was compared against the source data from which the original graphs were produced. Software data extraction was significantly faster, reducing time for extraction for 47%. Percent agreement between the two raters was 51% for manual and 53.5% for software data extraction. Percent agreement between the raters and original data was 66% vs. 75% for the first rater and 69% vs. 73% for the second rater, for manual and software extraction, respectively. Data extraction from figures should be conducted using software, whereas manual estimation should be avoided. Using software for data extraction of data presented only in figures is faster and enables higher interrater reliability. Copyright © 2016 Elsevier Inc. All rights reserved.
Display format, highlight validity, and highlight method: Their effects on search performance
NASA Technical Reports Server (NTRS)
Donner, Kimberly A.; Mckay, Tim D.; Obrien, Kevin M.; Rudisill, Marianne
1991-01-01
Display format and highlight validity were shown to affect visual display search performance; however, these studies were conducted on small, artificial displays of alphanumeric stimuli. A study manipulating these variables was conducted using realistic, complex Space Shuttle information displays. A 2x2x3 within-subjects analysis of variance found that search times were faster for items in reformatted displays than for current displays. Responses to valid applications of highlight were significantly faster than responses to non or invalidly highlighted applications. The significant format by highlight validity interaction showed that there was little difference in response time to both current and reformatted displays when the highlight validity was applied; however, under the non or invalid highlight conditions, search times were faster with reformatted displays. A separate within-subject analysis of variance of display format, highlight validity, and several highlight methods did not reveal a main effect of highlight method. In addition, observed display search times were compared to search time predicted by Tullis' Display Analysis Program. Benefits of highlighting and reformatting displays to enhance search and the necessity to consider highlight validity and format characteristics in tandem for predicting search performance are discussed.
Modular socket system versus traditionally laminated socket: a cost analysis.
Normann, Elna; Olsson, Anna; Brodtkorb, Thor-Henrik
2011-03-01
Using the new modular socket system (MSS) to produce a prosthetic socket directly on the patient has the potential of being easier and quicker to manufacture but also incurring higher costs. The purpose of the study was to compare the costs of manufacturing a transtibial prosthetic socket using either a MSS or a standard laminated socket (PC). Concurrent controlled trial. A total of 20 patients at two orthopaedic facilities were followed with regards to the cost of manufacturing a prosthetic socket using either MSS or PC. Time aspects and material costs were considered in the cost analysis. Other factors studied include delivery time and number of visits. For the cost analysis, only direct costs pertaining to the prosthetic socket were considered. The total cost of MSS was found to be significantly higher (p < 0.01) compared to PC. However, the production and time cost was significantly lower. Delivery time to the patient was 1 day for MSS compared to 17 days for PC. Our study shows that the direct prosthetic cost of treating a patient using MSS is significantly higher than treating a patient using PC. However, the MSS prosthesis can be delivered significantly faster and with fewer visits. Further studies taking the full societal costs of MSS into account should therefore be performed. This study shows that the direct prosthetic cost of treating a patient with Modular Socket System is significantly higher than treating a patient with plastercasting with standard laminated socket. However, the Modular Socket System prosthesis can be delivered significantly faster and with fewer visits.
Sequence-based heuristics for faster annotation of non-coding RNA families.
Weinberg, Zasha; Ruzzo, Walter L
2006-01-01
Non-coding RNAs (ncRNAs) are functional RNA molecules that do not code for proteins. Covariance Models (CMs) are a useful statistical tool to find new members of an ncRNA gene family in a large genome database, using both sequence and, importantly, RNA secondary structure information. Unfortunately, CM searches are extremely slow. Previously, we created rigorous filters, which provably sacrifice none of a CM's accuracy, while making searches significantly faster for virtually all ncRNA families. However, these rigorous filters make searches slower than heuristics could be. In this paper we introduce profile HMM-based heuristic filters. We show that their accuracy is usually superior to heuristics based on BLAST. Moreover, we compared our heuristics with those used in tRNAscan-SE, whose heuristics incorporate a significant amount of work specific to tRNAs, where our heuristics are generic to any ncRNA. Performance was roughly comparable, so we expect that our heuristics provide a high-quality solution that--unlike family-specific solutions--can scale to hundreds of ncRNA families. The source code is available under GNU Public License at the supplementary web site.
Chen, Xilin; Gestring, Mark L; Rosengart, Matthew R; Peitzman, Andrew B; Billiar, Timothy R; Sperry, Jason L; Brown, Joshua B
2018-05-04
Trauma is a time sensitive disease. Helicopter emergency medical services (HEMS) have shown benefit over ground EMS (GEMS), which may be related to reduced prehospital time. The distance at which this time benefit emerges depends on many factors that can vary across regions. Our objective was to determine the threshold distance at which HEMS has shorter prehospital time than GEMS under different conditions. Patients in the PA trauma registry 2000-2013 were included. Distance between zip centroid and trauma center was calculated using straight-line distance for HEMS and driving distance from GIS network analysis for GEMS. Contrast margins from linear regression identified the threshold distance at which HEMS had a significantly lower prehospital time than GEMS, indicated by non-overlapping 95% confidence intervals. The effect of peak traffic times and adverse weather on the threshold distance was evaluated. Geographic effects across EMS regions were also evaluated. A total of 144,741 patients were included with 19% transported by HEMS. Overall, HEMS became faster than GEMS at 7.7miles from the trauma center (p=0.043). HEMS became faster at 6.5miles during peak traffic (p=0.025) compared to 7.9miles during off-peak traffic (p=0.048). Adverse weather increased the distance at which HEMS was faster to 17.1miles (p=0.046) from 7.3miles in clear weather (p=0.036). Significant variation occurred across EMS regions, with threshold distances ranging from 5.4miles to 35.3miles. There was an inverse but non-significant relationship between urban population and threshold distance across EMS regions (ρ -0.351, p=0.28). This is the first study to demonstrate that traffic, weather, and geographic region significantly impact the threshold distance at which HEMS is faster than GEMS. HEMS was faster at shorter distances during peak traffic while adverse weather increased this distance. The threshold distance varied widely across geographic region. These factors must be considered to guide appropriate HEMS triage protocols. III, Therapeutic.
Grudinin, Sergei; Garkavenko, Maria; Kazennov, Andrei
2017-05-01
A new method called Pepsi-SAXS is presented that calculates small-angle X-ray scattering profiles from atomistic models. The method is based on the multipole expansion scheme and is significantly faster compared with other tested methods. In particular, using the Nyquist-Shannon-Kotelnikov sampling theorem, the multipole expansion order is adapted to the size of the model and the resolution of the experimental data. It is argued that by using the adaptive expansion order, this method has the same quadratic dependence on the number of atoms in the model as the Debye-based approach, but with a much smaller prefactor in the computational complexity. The method has been systematically validated on a large set of over 50 models collected from the BioIsis and SASBDB databases. Using a laptop, it was demonstrated that Pepsi-SAXS is about seven, 29 and 36 times faster compared with CRYSOL, FoXS and the three-dimensional Zernike method in SAStbx, respectively, when tested on data from the BioIsis database, and is about five, 21 and 25 times faster compared with CRYSOL, FoXS and SAStbx, respectively, when tested on data from SASBDB. On average, Pepsi-SAXS demonstrates comparable accuracy in terms of χ 2 to CRYSOL and FoXS when tested on BioIsis and SASBDB profiles. Together with a small allowed variation of adjustable parameters, this demonstrates the effectiveness of the method. Pepsi-SAXS is available at http://team.inria.fr/nano-d/software/pepsi-saxs.
Singer product apertures-A coded aperture system with a fast decoding algorithm
NASA Astrophysics Data System (ADS)
Byard, Kevin; Shutler, Paul M. E.
2017-06-01
A new type of coded aperture configuration that enables fast decoding of the coded aperture shadowgram data is presented. Based on the products of incidence vectors generated from the Singer difference sets, we call these Singer product apertures. For a range of aperture dimensions, we compare experimentally the performance of three decoding methods: standard decoding, induction decoding and direct vector decoding. In all cases the induction and direct vector methods are several orders of magnitude faster than the standard method, with direct vector decoding being significantly faster than induction decoding. For apertures of the same dimensions the increase in speed offered by direct vector decoding over induction decoding is better for lower throughput apertures.
The effect of an acute ingestion of Turkish coffee on reaction time and time trial performance.
Church, David D; Hoffman, Jay R; LaMonica, Michael B; Riffe, Joshua J; Hoffman, Mattan W; Baker, Kayla M; Varanoske, Alyssa N; Wells, Adam J; Fukuda, David H; Stout, Jeffrey R
2015-01-01
The purpose of this study was to examine the ergogenic benefits of Turkish coffee consumed an hour before exercise. In addition, metabolic, cardiovascular, and subjective measures of energy, focus and alertness were examined in healthy, recreationally active adults who were regular caffeine consumers (>200 mg per day). Twenty males (n = 10) and females (n = 10), age 24.1 ± 2.9 y; height 1.70 ± 0.09 m; body mass 73.0 ± 13.0 kg (mean ± SD), ingested both Turkish coffee [3 mg · kg(-1) BW of caffeine, (TC)], and decaffeinated Turkish coffee (DC) in a double-blind, randomized, cross-over design. Performance measures included a 5 km time trial, upper and lower body reaction to visual stimuli, and multiple object tracking. Plasma caffeine concentrations, blood pressure (BP), heart rate and subjective measures of energy, focus and alertness were assessed at baseline (BL), 30-min following coffee ingestion (30+), prior to endurance exercise (PRE) and immediately-post 5 km (IP). Metabolic measures [VO2, V E , and respiratory exchange rate (RER)] were measured during the 5 km. Plasma caffeine concentrations were significantly greater during TC (p < 0.001) at 30+, PRE, and IP compared to DC. Significantly higher energy levels were reported at 30+ and PRE for TC compared to DC. Upper body reaction performance (p = 0.023) and RER (p = 0.019) were significantly higher for TC (85.1 ± 11.6 "hits," and 0.98 ± 0.05 respectively) compared to DC (81.2 ± 13.7 "hits," and 0.96 ± 0.05, respectively). Although no significant differences (p = 0.192) were observed in 5 km run time, 12 of the 20 subjects ran faster (p = 0.012) during TC (1662 ± 252 s) compared to DC (1743 ± 296 s). Systolic BP was significantly elevated during TC in comparison to DC. No other differences (p > 0.05) were noted in any of the other performance or metabolic measures. Acute ingestion of TC resulted in a significant elevation in plasma caffeine concentrations within 30-min of consumption. TC ingestion resulted in significant performance benefits in reaction time and an increase in subjective feelings of energy in habitual caffeine users. No significant differences were noted in time for the 5 km between trials, however 60 % of the participants performed the 5 km faster during the TC trial and were deemed responders. When comparing TC to DC in responders only, significantly faster times were noted when consuming TC compared to DC. No significant benefits were noted in measures of cognitive function.
Accelerating gravitational microlensing simulations using the Xeon Phi coprocessor
NASA Astrophysics Data System (ADS)
Chen, B.; Kantowski, R.; Dai, X.; Baron, E.; Van der Mark, P.
2017-04-01
Recently Graphics Processing Units (GPUs) have been used to speed up very CPU-intensive gravitational microlensing simulations. In this work, we use the Xeon Phi coprocessor to accelerate such simulations and compare its performance on a microlensing code with that of NVIDIA's GPUs. For the selected set of parameters evaluated in our experiment, we find that the speedup by Intel's Knights Corner coprocessor is comparable to that by NVIDIA's Fermi family of GPUs with compute capability 2.0, but less significant than GPUs with higher compute capabilities such as the Kepler. However, the very recently released second generation Xeon Phi, Knights Landing, is about 5.8 times faster than the Knights Corner, and about 2.9 times faster than the Kepler GPU used in our simulations. We conclude that the Xeon Phi is a very promising alternative to GPUs for modern high performance microlensing simulations.
Deconstructing Planning Ability in Children and Adolescents with Anorexia Nervosa.
Rose, Mark; Reville, Marie-Claire; Iszatt, Amber; Levinson, Simon; Frampton, Ian; Lask, Bryan
2017-01-01
Weaknesses in planning by patients with anorexia nervosa (AN) have been noted (e.g., Zakzanis, Campbell, & Polsinelli, 2010 ) and are generally based on adults. This study explored D-KEFS Tower Test performance to better understand learning styles and strategies used by child and adolescent patients with AN compared to healthy controls. Overall, no significant differences were found in achievement; however, Item 5 predicted performance across harder items. The AN group was significantly faster to move their first disc suggesting patients with AN did not spend as much time planning their strategies for item completion. The findings of this study in conjunction with other studies investigating planning in AN may suggest the existence of subtle differences in learning style and strategy, such as faster initiation times, rather than gross planning differences. Further research is required to better understand the relationship between these subtle differences and clinical presentations.
UAH mathematical model of the variable polarity plasma ARC welding system calculation
NASA Technical Reports Server (NTRS)
Hung, R. J.
1994-01-01
Significant advantages of Variable Polarity Plasma Arc (VPPA) welding process include faster welding, fewer repairs, less joint preparation, reduced weldment distortion, and absence of porosity. A mathematical model is presented to analyze the VPPA welding process. Results of the mathematical model were compared with the experimental observation accomplished by the GDI team.
Dodawad, Ravichandra; G. B., Sumalatha; Pandarpurkar, Sandeep; Jajee, Parashuram
2016-01-01
Background A pain-free postoperative period is essential following a caesarean section so new mothers may care for and bond with their neonates. Intrathecal adjuvants are often administered during this procedure to provide significant analgesia, but they may also have bothersome side effects. Intrathecal midazolam produces effective postoperative analgesia with no significant side effects. Objectives This prospective, randomized, double-blind study was designed to compare the analgesic efficacy and safety of intrathecal midazolam vs. plain bupivacaine as an adjunct to bupivacaine in pregnancy-induced hypertension patients scheduled for elective caesarean section. Methods Sixty patients diagnosed with pregnancy-induced hypertension on regular treatment who were scheduled for a caesarean section were randomly allocated into two groups: a control group (Group BC, n = 30) and a midazolam group (Group BM, n = 30). Both groups received 10 mg (2 mL) of 0.5% hyperbaric bupivacaine. Group BC received 0.4 mL of distilled water, while group BM received 0.4 mL (2 mg) of midazolam intrathecally. The duration of postoperative analgesia, analgesic requirements during the first 24 hours after surgery, onset times and durations of sensory and motor blocks, incidence of hypotension, vasopressor requirements, and side effects were recorded. Results Postoperative analgesia was significantly longer in the midazolam group compared to the control group (201.5 minutes vs. 357.6 minutes). The mean onset times of the sensory and motor blocks were significantly faster (P < 0.01) in the midazolam group compared to the control group. The mean times to attain the maximum sensory level and motor blocks were also significantly faster in the midazolam group compared to the control group (P < 0.05). The incidence of hypotension was 6.6% in the midazolam group and 36.6% in the control group, which was highly significant. In addition, the number of patients with side effects was significantly lower in the midazolam group compared to the control group. Conclusions Intrathecal midazolam 2 mg provides significantly longer and effective postoperative analgesia with no side effects. PMID:27847698
Schill, Matthew R.; Varela, J. Esteban; Frisella, Margaret M.; Brunt, L. Michael
2015-01-01
Background We compared performance of validated laparoscopic tasks on four commercially available single site access (SSA) access devices (AD) versus an independent port (IP) SSA set-up. Methods A prospective, randomized comparison of laparoscopic skills performance on four AD (GelPOINT™, SILS™ Port, SSL Access System™, TriPort™) and one IP SSA set-up was conducted. Eighteen medical students (2nd–4th year), four surgical residents, and five attending surgeons were trained to proficiency in multi-port laparoscopy using four laparoscopic drills (peg transfer, bean drop, pattern cutting, extracorporeal suturing) in a laparoscopic trainer box. Drills were then performed in random order on each IP-SSA and AD-SSA set-up using straight laparoscopic instruments. Repetitions were timed and errors recorded. Data are mean ± SD, and statistical analysis was by two-way ANOVA with Tukey HSD post-hoc tests. Results Attending surgeons had significantly faster total task times than residents or students (p< 0.001), but the difference between residents and students was NS. Pair-wise comparisons revealed significantly faster total task times for the IP-SSA set-up compared to all four AD-SSA’s within the student group only (p<0.05). Total task times for residents and attending surgeons showed a similar profile, but the differences were NS. When data for the three groups was combined, the total task time was less for the IP-SSA set-up than for each of the four AD-SSA set-ups (p < 0.001). Similarly,, the IP-SSA set-up was significantly faster than 3 of 4 AD-SSA set-ups for peg transfer, 3 of 4 for pattern cutting, and 2 of 4 for suturing. No significant differences in error rates between IP-SSA and AD-SSA set-ups were detected. Conclusions When compared to an IP-SSA laparoscopic set-up, single site access devices are associated with longer task performance times in a trainer box model, independent of level of training. Task performance was similar across different SSA devices. PMID:21993938
Elith, Craig A; Dempsey, Shane E; Warren-Forward, Helen M
2013-01-01
Introduction The primary aim of this study is to compare intensity modulated radiation therapy (IMRT) to volumetric modulated arc therapy (VMAT) for the radical treatment of prostate cancer using version 10.0 (v10.0) of Varian Medical Systems, RapidArc radiation oncology system. Particular focus was placed on plan quality and the implications on departmental resources. The secondary objective was to compare the results in v10.0 to the preceding version 8.6 (v8.6). Methods Twenty prostate cancer cases were retrospectively planned using v10.0 of Varian's Eclipse and RapidArc software. Three planning techniques were performed: a 5-field IMRT, VMAT using one arc (VMAT-1A), and VMAT with two arcs (VMAT-2A). Plan quality was assessed by examining homogeneity, conformity, the number of monitor units (MUs) utilized, and dose to the organs at risk (OAR). Resource implications were assessed by examining planning and treatment times. The results obtained using v10.0 were also compared to those previously reported by our group for v8.6. Results In v10.0, each technique was able to produce a dose distribution that achieved the departmental planning guidelines. The IMRT plans were produced faster than VMAT plans and displayed improved homogeneity. The VMAT plans provided better conformity to the target volume, improved dose to the OAR, and required fewer MUs. Treatments using VMAT-1A were significantly faster than both IMRT and VMAT-2A. Comparison between versions 8.6 and 10.0 revealed that in the newer version, VMAT planning was significantly faster and the quality of the VMAT dose distributions produced were of a better quality. Conclusion VMAT (v10.0) using one or two arcs provides an acceptable alternative to IMRT for the treatment of prostate cancer. VMAT-1A has the greatest impact on reducing treatment time. PMID:26229615
Self- or familiar-face recognition advantage? New insight using ambient images.
Bortolon, Catherine; Lorieux, Siméon; Raffard, Stéphane
2018-06-01
Self-face recognition has been widely explored in the past few years. Nevertheless, the current literature relies on the use of standardized photographs which do not represent daily-life face recognition. Therefore, we aim for the first time to evaluate self-face processing in healthy individuals using natural/ambient images which contain variations in the environment and in the face itself. In total, 40 undergraduate and graduate students performed a forced delayed-matching task, including images of one's own face, friend, famous and unknown individuals. For both reaction time and accuracy, results showed that participants were faster and more accurate when matching different images of their own face compared to both famous and unfamiliar faces. Nevertheless, no significant differences were found between self-face and friend-face and between friend-face and famous-face. They were also faster and more accurate when matching friend and famous faces compared to unfamiliar faces. Our results suggest that faster and more accurate responses to self-face might be better explained by a familiarity effect - that is, (1) the result of frequent exposition to one's own image through mirror and photos, (2) a more robust mental representation of one's own face and (3) strong face recognition units as for other familiar faces.
Effect of plasma actuator control parameters on a transitional flow
NASA Astrophysics Data System (ADS)
Das Gupta, Arnob; Roy, Subrata
2018-04-01
This study uses a wall-resolved implicit large eddy simulation to investigate the effects of different surface dielectric barrier discharge actuator parameters such as the geometry of the electrodes, frequency, amplitude of actuation and thermal effect. The actuator is used as a tripping device on a zero-pressure gradient laminar boundary layer flow. It is shown that the standard linear actuator creates structures like the Tollmien-Schlichting wave transition. The circular serpentine, square serpentine and spanwise actuators have subharmonic sinuous streak breakdown and behave like oblique wave transition scenario. The spanwise and square actuators cause comparably faster transition to turbulence. The square actuator adds energy into the higher spanwise wavenumber modes resulting in a faster transition compared to the circular actuator. When the Strouhal number of actuation is varied, the transition does not occur for a value below 0.292. Higher frequencies with same amplitude of actuation lead to faster transition. Small changes (<4%) in the amplitude of actuation can have a significant impact on the transition location which suggests that an optimal combination of frequency and amplitude exists for highest control authority. The thermal bumps approximating the actuator heating only shows localized effects on the later stages of transition for temperatures up to 373 K and can be ignored for standard actuators operating in subsonic regimes.
Faster Self-paced Rate of Drinking for Alcohol Mixed with Energy Drinks versus Alcohol Alone
Marczinski, Cecile A.; Fillmore, Mark T.; Maloney, Sarah F.; Stamates, Amy L.
2016-01-01
The consumption of alcohol mixed with energy drinks (AmED) has been associated with higher rates of binge drinking and impaired driving when compared to alcohol alone. However, it remains unclear why the risks of use of AmED are heightened compared to alcohol alone even when the doses of alcohol consumed are similar. Therefore, the purpose of this laboratory study was to investigate if the rate of self-paced beverage consumption was faster for a dose of AmED versus alcohol alone using a double-blind, within-subjects, placebo-controlled study design. Participants (n = 16) of equal gender who were social drinkers attended 4 separate test sessions that involved consumption of alcohol (1.97 ml/kg vodka) and energy drinks, alone and in combination. On each test day, the dose assigned was divided into 10 cups. Participants were informed that they would have a two hour period to consume the 10 drinks. After the self-paced drinking period, participants completed a cued go/no-go reaction time task and subjective ratings of stimulation and sedation. The results indicated that participants consumed the AmED dose significantly faster (by approximately 16 minutes) than the alcohol dose. For the performance task, participants’ mean reaction times were slower in the alcohol conditions and faster in the energy drink conditions. In conclusion, alcohol consumers should be made aware that rapid drinking might occur for AmED beverages thus heightening alcohol-related safety risks. The fast rate of drinking may be related to the generalized speeding of responses following energy drink consumption. PMID:27819431
Caputo, M P; Benson, E R; Pritchett, E M; Hougentogler, D P; Jain, P; Patil, C; Johnson, A L; Alphin, R L
2012-12-01
The mass depopulation of production birds remains an effective means of controlling fast-moving, highly infectious diseases such as avian influenza and virulent Newcastle disease. Two experiments were performed to compare the physiological responses of White Pekin commercial ducks during foam depopulation and CO(2) gas depopulation. Both experiment 1 (5 to 9 wk of age) and 2 (8 to 14 wk of age) used electroencephalogram, electrocardiogram, and accelerometer to monitor and evaluate the difference in time to unconsciousness, motion cessation, brain death, altered terminal cardiac activity, duration of bradycardia, and elapsed time from onset of bradycardia to onset of unconsciousness between foam and CO(2) gas. Experiment 2 also added a third treatment, foam + atropine injection, to evaluate the effect of suppressing bradycardia. Experiment 1 resulted in significantly shorter times for all 6 physiological points for CO(2) gas compared with foam, whereas experiment 2 found that there were no significant differences between foam and CO(2) gas for these physiological points except brain death, in which CO(2) was significantly faster than foam and duration of bradycardia, which was shorter for CO(2). Experiment 2 also determined there was a significant positive correlation between duration of bradycardia and time to unconsciousness, motion cessation, brain death, and altered terminal cardiac activity. The time to unconsciousness, motion cessation, brain death, and altered terminal cardiac activity was significantly faster for the treatment foam + atropine injection compared with foam. Both experiments showed that bradycardia can occur as a result of either submersion in foam or exposure to CO(2) gas. The duration of bradycardia has a significant impact on the time it takes White Pekin ducks to reach unconsciousness and death during depopulation.
Is Single-Port Laparoscopy More Precise and Faster with the Robot?
Fransen, Sofie A F; van den Bos, Jacqueline; Stassen, Laurents P S; Bouvy, Nicole D
2016-11-01
Single-port laparoscopy is a step forward toward nearly scar less surgery. Concern has been raised that single-incision laparoscopic surgery (SILS) is technically more challenging because of the lack of triangulation and the clashing of instruments. Robotic single-incision laparoscopic surgery (RSILS) in chopstick setting might overcome these problems. This study evaluated the outcome in time and errors of two tasks of the Fundamentals of Laparoscopic Surgery on a dry platform, in two settings: SILS versus RSILS. Nine experienced laparoscopic surgeons performed two tasks: peg transfer and a suturing task, on a standard box trainer. All participants practiced each task three times in both settings: SILS and a RSILS setting. The assessment scores (time and errors) were recorded. For the first task of peg transfer, RSILS was significantly better in time (124 versus 230 seconds, P = .0004) and errors (0.80 errors versus 2.60 errors, P = .024) at the first run, compared to the SILS setting. At the third and final run, RSILS still proved to be significantly better in errors (0.10 errors versus 0.80 errors, P = .025) compared to the SILS group. RSILS was faster in the third run, but not significant (116 versus 157 seconds, P = .08). For the second task, a suturing task, only 3 participants of the SILS group were able to perform this task within the set time frame of 600 seconds. There was no significant difference in time in the three runs between SILS and RSILS for the 3 participants that fulfilled both tasks within the 600 seconds. This study shows that robotic single-port surgery seems easier, faster, and more precise to perform basis tasks of the Fundamentals of laparoscopic surgery. For the more complex task of suturing, only the single-port robotic setting enabled all participants to fulfill this task, within the set time frame.
Tavakoli, J; Costi, J J
2018-04-15
While few studies have improved our understanding of composition and organization of elastic fibres in the inter-lamellar matrix (ILM), its clinical relevance is not fully understood. Moreover, no studies have measured the direct tensile and shear failure and viscoelastic properties of the ILM. Therefore, the aim of this study was, for the first time, to measure the viscoelastic and failure properties of the ILM in both the tension and shear directions of loading. Using an ovine model, isolated ILM samples were stretched to 40% of their initial length at three strain rates of 0.1%s -1 (slow), 1%s -1 (medium) and 10%s -1 (fast) and a ramp test to failure was performed at a strain rate of 10%s -1 . The findings from this study identified that the stiffness of the ILM was significantly larger at faster strain rates, and energy absorption significantly smaller, compared to slower strain rates, and the viscoelastic and failure properties were not significantly different under tension and shear loading. We found a strain rate dependent response of the ILM during dynamic loading, particularly at the fastest rate. The ILM demonstrated a significantly higher capability for energy absorption at slow strain rates compared to medium and fast strain rates. A significant increase in modulus was found in both loading directions and all strain rates, having a trend of larger modulus in tension and at faster strain rates. The finding of no significant difference in failure properties in both loading directions, was consistent with our previous ultra-structural studies that revealed a well-organized (±45°) elastic fibre orientation in the ILM. The results from this study can be used to develop and validate finite element models of the AF at the tissue scale, as well as providing new strategies for fabricating tissue engineered scaffolds. While few studies have improved our understanding of composition and organization of elastic fibres in the inter-lamellar matrix (ILM) of the annulus in the disc no studies have measured the direct mechanical failure and viscoelastic properties of the ILM. The findings from this study identified that the stiffness of the ILM was significantly larger at faster strain rates, and energy absorption significantly smaller, compared to slower strain rates. The failure properties of the ILM were not significantly different under tension and shear. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Alshamsi, Shaikha; Binsaleh, Fatima; Hejaili, Fayez; Karkar, Ayman; Moussa, Dujana; Raza, Hamad; Parbat, Parkash; Al Suwida, Abdulkareem; Alobaili, Saad; AlSehli, R; Al Sayyari, Abdulla
2016-04-01
This paper aimed to study the effect of Ramadan fasting on biochemical and clinical parameters and compliance for dialysis. A prospective multicenter observational cross-sectional study comparing fasting with a non-fasting stable adult hemodialysis patients for demographic and biochemical parameters, compliance with dialysis, inter-dialytic weight gain, pre- and post-blood pressure, and frequency of intradialytic hypotensive episodes was carried out. Six hundred thirty-five patients, of whom 64.1% fasted, were studied. The fasters were younger (53.3 ± 16.2 vs. 58.4 ± 16.1 years; P = 0.001) but had similar duration on dialysis (P = 0.35). More fasters worked (22.0% vs. 14.6%; P = 0.001) and missed dialysis sessions during Ramadan. No differences were noted between groups in sex, diabetic status, or dialysis shift or day. There were no differences in the pre- and post-dialysis blood pressure; serum potassium, albumin or weight gain; diabetic status; sex; and dialysis shift time or days. However, serum phosphorous was significantly higher in the fasting group (2.78 ± 1.8 vs. 2.45 ± 1.6 mmol/L; P = 0.045). There were no intragroup differences in any of the parameters studied when comparing the findings during Ramadan with those in the month before Ramadan. Fasters were significantly younger and more likely to be working, to miss dialysis sessions, and to have higher serum phosphorous levels. No other differences were observed. © 2015 International Society for Hemodialysis.
An enhanced high-speed multi-digit BCD adder using quantum-dot cellular automata
NASA Astrophysics Data System (ADS)
Ajitha, D.; Ramanaiah, K. V.; Sumalatha, V.
2017-02-01
The advent of development of high-performance, low-power digital circuits is achieved by a suitable emerging nanodevice called quantum-dot cellular automata (QCA). Even though many efficient arithmetic circuits were designed using QCA, there is still a challenge to implement high-speed circuits in an optimized manner. Among these circuits, one of the essential structures is a parallel multi-digit decimal adder unit with significant speed which is very attractive for future environments. To achieve high speed, a new correction logic formulation method is proposed for single and multi-digit BCD adder. The proposed enhanced single-digit BCD adder (ESDBA) is 26% faster than the carry flow adder (CFA)-based BCD adder. The multi-digit operations are also performed using the proposed ESDBA, which is cascaded innovatively. The enhanced multi-digit BCD adder (EMDBA) performs two 4-digit and two 8-digit BCD addition 50% faster than the CFA-based BCD adder with the nominal overhead of the area. The EMDBA performs two 4-digit BCD addition 24% faster with 23% decrease in the area, similarly for 8-digit operation the EMDBA achieves 36% increase in speed with 21% less area compared to the existing carry look ahead (CLA)-based BCD adder design. The proposed multi-digit adder produces significantly less delay of (N –1) + 3.5 clock cycles compared to the N* One digit BCD adder delay required by the conventional BCD adder method. It is observed that as per our knowledge this is the first innovative proposal for multi-digit BCD addition using QCA.
Muiños, Mónica; Ballesteros, Soledad
2014-11-01
The present study investigated peripheral vision (PV) and perceptual asymmetries in young and older martial arts athletes (judo and karate athletes) and compared their performance with that of young and older nonathletes. Stimuli were dots presented at three different eccentricities along the horizontal, oblique, and vertical diameters and three interstimulus intervals. Experiment 1 showed that although the two athlete groups were faster in almost all conditions, karate athletes performed significantly better than nonathlete participants when stimuli were presented in the peripheral visual field. Experiment 2 showed that older participants who had practiced a martial art at a competitive level when they were young were significantly faster than sedentary older adults of the same age. The practiced sport (judo or karate) did not affect performance differentially, suggesting that it is the practice of martial arts that is the crucial factor, rather than the type of martial art. Importantly, older athletes lose their PV advantage, as compared with young athletes. Finally, we found that physical activity (young and older athletes) and age (young and older adults) did not alter the visual asymmetries that vary as a function of spatial location; all participants were faster for stimuli presented along the horizontal than for those presented along the vertical meridian and for those presented at the lower rather than at the upper locations within the vertical meridian. These results indicate that the practice of these martial arts is an effective way of counteracting the processing speed decline of visual stimuli appearing at any visual location and speed.
Derosa, Giuseppe; Maffioli, Pamela; Ferrari, Ilaria; Palumbo, Ilaria; Randazzo, Sabrina; D'Angelo, Angela; Cicero, Arrigo F G
2010-01-01
Comparison of the effects of one year treatment with sibutramine compared to placebo on insulin resistance parameters, body weight, glycemic control, and lipid profile, in type 2 diabetic patients. Two hundred and forty-six patients with uncontrolled type 2 diabetes mellitus in therapy with different oral hypoglycemic agents or insulin were enrolled in this study and randomised to take sibutramine 10 mg or placebo for one year. We evaluated at baseline, and after 3, 6, 9, and 12 months these parameters: homeostasis model assessment insulin resistance index (HOMA-IR), retinol binding protein-4 (RBP-4), resistin, visfatin, and high sensitivity-C reactive protein (Hs-CRP), body weight, body mass index (BMI), glycated hemoglobin (HbA(₁c)), fasting plasma glucose (FPG), post-prandial plasma glucose (PPG), fasting plasma insulin (FPI), total cholesterol (TC), low density lipoprotein-cholesterol (LDL-C), high density lipoprotein-cholesterol (HDL-C), and triglycerides (T(g)). A faster decrease of HOMA-IR, resistin, and RBP-4 was recorded with sibutramine compared to the control group. We observed a significant decrease of Hs-CRP in both groups, and a faster improvement of HbA(₁c), FPG and PPG with sibutramine compared to the control group; furthermore we recorded a decrease of FPI, TC, LDL-C, body weight, and BMI in the sibutramine group, but not in the control group. Sibutramine gave a faster improvement of insulin resistance parameters and glycemic control compared to placebo; furthermore sibutramine gave also an improvement of lipid profile, and body weight.
Erwin; Gunanti; Handharyani, Ekowati; Noviana, Deni
2016-05-01
The success of a skin graft in a cat is highly dependent on the granulation formed by the base of recipient bed. Granulation by the base of recipient bed will form after several days after injury. This research aimed to observe subjective and objective profile of skin graft recovery on forelimb of cats with different periods of donor skin placement. Nine male Indonesian local cats aged 1-2 years old, weighing 3-4 kg were divided into three groups. The first surgery for creating defect wound of 2 cm×2 cm in size was performed in the whole group. The wound was left for several days with the respective interval for each group, respectively: Group I (for 2 days), Group II (for 4 days), and Group III (for 6 days). In the whole group, the second surgery was done by the harvesting skin of thoracic area which then applied on recipient bed of respective groups. The donor skin on Group II was accepted faster compared to Group I and Group III. The donor skin did not show color differences compared to surrounding skin, painless, bright red in bleeding test had faster both hair growth and drug absorption. Test toward the size of donor skin and the effect of drugs did not show a significant difference between each group. The observe subjective and objective profile of skin graft recovery on forelimb of cats on Group II were accepted faster compared to Group I and III.
The utility of a "trauma 1 OP" activation at a level 1 pediatric trauma center.
Hunt, Madison M; Stevens, Austin M; Hansen, Kristine W; Fenton, Stephen J
2017-02-01
To expedite flow of injured children suspected to require operative intervention, a "trauma 1 OP" (T1OP) activation classification was created. The purpose of this study was to review this strategy at a level 1 pediatric trauma center. A retrospective review of T1OP activations between 2003 and 2015 was performed. Children suspected of requiring neurosurgical intervention were classified as trauma 1 OP neuro (T1OP(N)). Comparisons were made to trauma 1 (T1) patients who required emergent operative intervention, excluding orthopedic injuries. Overall, 461 T1OP activations occurred (72% T1OP(N)) compared to 129 T1 activations requiring emergent surgery. Demographics were not significantly different between groups, although T1OP patients were slightly younger and more often experienced falls or were victims of abuse. Compared to T1 activations, T1OP activations had a significantly higher mortality rate (21% vs. 7%, p<0.001). Repeat head imaging was more common in the T1OP(N) group compared to imaged children in the T1 group (20% vs. 37%, p=0.05). T1OP(N) patients more often went directly to the OR (45% vs. 33%, p=0.02) and did so in a significantly faster period of time (32min vs. 53min, p<0.001). Use of the T1OP activations appropriately triaged surgical patients, resulting in significantly faster transport times to the OR. II, prognosis study. Copyright © 2017 Elsevier Inc. All rights reserved.
Assessment of Chicken-Egg Membrane as a Dressing for Wound Healing.
Guarderas, Fernando; Leavell, Yaowaree; Sengupta, Trisha; Zhukova, Mariya; Megraw, Timothy L
2016-03-01
To examine the efficacy of the folk remedy of chicken-egg membrane dressing on wound healing. Full-thickness excisional wounds were created on 14 male Sprague-Dawley rats in 2 separate trials. Each animal received 2 wounds on the upper back. One wound was untreated, and the other was dressed with chicken-egg membrane to assess its impact on wound healing. Half of the rats received egg membrane treatment on the inferior wound, whereas the other half received egg membrane treatment on the superior wound. Membrane replacement, wound debridement, and imaging were done on days 5, 8, and 10 and then imaging continued on days 12, 14, 16, 18, and 20 of the experiment. Healing rate was measured based on the wound area over the 20 days of the experiment. The wounds dressed with chicken-egg membrane had a significantly (P < .01) faster rate of healing compared with the control at the early stages of healing between days 0 and 5. This group healed 21% faster during this early phase, compared with the control group. Overall, however, wound healing rates were indistinguishable from days 5 to 20. Chicken-egg membrane dressing significantly improves healing of cutaneous wounds in the early stages of wound healing.
Video Capsule Endoscopy: A Tool for the Assessment of Small Bowel Transit Time.
Hejazi, Reza A; Bashashati, Mohammad; Saadi, Mohammed; Mulla, Zuber D; Sarosiek, Irene; McCallum, Richard W; Zuckerman, Marc J
2016-01-01
Video capsule endoscopy (VCE) is a procedure that uses a wireless camera to take pictures of the gastrointestinal (GI) tract. A wireless motility capsule (WMC) of a similar size has been developed, which measures pH, pressure, and temperature and can be used to assess regional and total GI transit times. VCE could also potentially be used as a tool for measuring small bowel transit time (SBTT). This study was designed to obtain SBTT from VCE and compare it with historical data generated by WMC. Gastric transit time (GTT) was also measured. Patients were included if the indication for VCE was either iron deficiency anemia (IDA) or overt obscure GI bleed (OOGIB), and they did not have any known motility disorder. Results from VCE were also compared in diabetic vs. non-diabetic patients. There were a total of 147 VCE studies performed, including 42 for OOGIB and 105 for IDA. Median GTT and SBTT were 0.3 and 3.6 h, respectively. The overall median GTT and SBTT were 0.3 and 3.6 h, respectively, in the IDA group compared with 0.3 and 3.4 h in the OOGIB group. When compared with WMC, the GTT and SBTT were significantly faster in both groups (GTT: 3.6 h and SBTT: 4.6 h). The median GTT and SBTT were not significantly different in diabetics vs. non-diabetics [GTT: 17.5 vs. 18.0 min (P = 0.86) and SBTT: 3.9 h (237 min) vs. 3.8 h (230 min), respectively (P = 0.90)]. SBTT as measured using VCE is not significantly different in OOGIB compared with IDA. Both GTT and SBTT are significantly faster as assessed by VCE, which is initiated in the fasting state, compared with WMC measurement, which is initiated after a standard meal. In summary, VCE could potentially be used for measuring SBTT in the fasting state.
Bhaskar, Anusha; Nithya, V
2012-01-01
To investigate the wound-healing potency of the ethanolic extract of the flowers of Hibiscus rosa sinensis. The wound-healing activity of H. rosa sinensis (5 and 10% w/w) on Wistar albino rats was studied using three different models viz., excision, incision and dead space wound. The parameters studied were breaking strength in incision model, granulation tissue dry weight, breaking strength and collagen content in dead space wound model, percentage of wound contraction and period of epithelization in excision wound model. The granulation tissue formed on days 4, 8, 12, and 16 (post-wound) was used to estimate total collagen, hexosamine, protein, DNA and uronic acid. Data were analyzed by Analysis of Variance (ANOVA) test. P<0.05 was considered statistically significant. The extract increased cellular proliferation and collagen synthesis at the wound site, as evidenced by increase in DNA, total protein and total collagen content of granulation tissues. The extract-treated wounds were found to heal much faster as indicated by improved rates of epithelialization and wound contraction. The extract of H. rosa sinensis significantly (P<0.001) increased the wound-breaking strength in the incision wound model compared to controls. The extract-treated wounds were found to epithelialize faster, and the rate of wound contraction was significantly (P<0.001) increased as compared to control wounds. Wet and dry granulation tissue weights in a dead space wound model increased significantly (P<0.001). There was a significant increase in wound closure rate, tensile strength, dry granuloma weight, wet granuloma weight and decrease in epithelization period in H. rosa sinensis-treated group as compared to control and standard drug-treated groups. The ethanolic extract of H. rosa sinensis had greater wound-healing activity than the nitrofurazone ointment.
Otwell, Anne E; Callister, Stephen J; Sherwood, Robert W; Zhang, Sheng; Goldman, Abby R; Smith, Richard D; Richardson, Ruth E
2018-06-15
We established Fe(III)-reducing co-cultures of two species of metal-reducing bacteria, the Gram-positive Desulfotomaculum reducens MI-1 and the Gram-negative Geobacter sulfurreducens PCA. Co-cultures were given pyruvate, a substrate that D. reducens can ferment and use as electron donor for Fe(III) reduction. G. sulfurreducens relied upon products of pyruvate oxidation by D. reducens (acetate, hydrogen) for use as electron donor in the co-culture. Co-cultures reduced Fe(III) to Fe(II) robustly, and Fe(II) was consistently detected earlier in co-cultures than pure cultures. Notably, faster cell growth, and correspondingly faster pyruvate oxidation, was observed by D. reducens in co-cultures. Global comparative proteomic analysis was performed to observe differential protein abundance during co-culture vs. pure culture growth. Proteins previously associated with Fe(III) reduction in G. sulfurreducens, namely c-type cytochromes and type IV pili proteins, were significantly increased in abundance in co-cultures relative to pure cultures. D. reducens ribosomal proteins were significantly increased in co-cultures, likely a reflection of faster growth rates observed for D. reducens cells while in co-culture. Furthermore, we developed multiple reaction monitoring (MRM) assays to quantitate specific biomarker peptides. The assays were validated in pure and co-cultures, and protein abundance ratios from targeted MRM and global proteomic analysis correlate significantly. © 2018 John Wiley & Sons Ltd.
Age-related differences in recovery from inhalational anesthesia: a retrospective study.
Tsukamoto, Masanori; Yamanaka, Hitoshi; Yokoyama, Takeshi
2018-03-03
It is important to understand the anesthetic requirements of elderly patients. However, little is known about age-related recovery from inhalational anesthetics. In this retrospective study, we compared age-related differences in recovery from three inhalational anesthetics in elderly subjects. Patients were investigated as three age groups which can be defined as age ranges pediatric (< 15 years), adult (15-64 years), and elderly patients ( > 65 years) under general anesthesia using inhalational anesthetics. Anesthesia and surgery times, drug end-tidal concentrations, the time to first movement, time to eye opening, body movement, extubation, and discharge were recorded. The data were analyzed using a Kruskal-Wallis test and Steel-Dwass multiple comparisons. A total of 594 patients were included in the study. In inhalational anesthetics such as sevoflurane, isoflurane, or desflurane, recovery from general anesthesia was not significantly different among age groups (P > 0.05). In inhalational group, recovery was significantly 5-40% faster in desflurane group than in other inhalational anesthetics groups (P < 0.05). There were 20% faster recovery in pediatric and adult groups with desflurane than in elderly with desflurane group. Drug end-tidal inhalational concentrations in pediatric group were significantly higher than that in adult and elderly groups of all inhalational anesthetics, respectively (P < 0.05). In the current study, we have found that recovery from desflurane was faster in younger patients than in other inhalational anesthetics and aged patients.
Murray, Brad R.; Hardstaff, Lyndle K.; Phillips, Megan L.
2013-01-01
The flammability of plant leaves influences the spread of fire through vegetation. Exotic plants invading native vegetation may increase the spread of bushfires if their leaves are more flammable than native leaves. We compared fresh-leaf and dry-leaf flammability (time to ignition) between 52 native and 27 exotic plant species inhabiting dry sclerophyll forest. We found that mean time to ignition was significantly faster in dry exotic leaves than in dry native leaves. There was no significant native-exotic difference in mean time to ignition for fresh leaves. The significantly higher fresh-leaf water content that was found in exotics, lost in the conversion from a fresh to dry state, suggests that leaf water provides an important buffering effect that leads to equivalent mean time to ignition in fresh exotic and native leaves. Exotic leaves were also significantly wider, longer and broader in area with significantly higher specific leaf area–but not thicker–than native leaves. We examined scaling relationships between leaf flammability and leaf size (leaf width, length, area, specific leaf area and thickness). While exotics occupied the comparatively larger and more flammable end of the leaf size-flammability spectrum in general, leaf flammability was significantly correlated with all measures of leaf size except leaf thickness in both native and exotic species such that larger leaves were faster to ignite. Our findings for increased flammability linked with larger leaf size in exotics demonstrate that exotic plant species have the potential to increase the spread of bushfires in dry sclerophyll forest. PMID:24260169
Ramadan fasting in patients with adrenal insufficiency.
Chihaoui, Mélika; Chaker, Fatma; Yazidi, Meriem; Grira, Wafa; Ben Amor, Zohra; Rejeb, Ons; Slimane, Hedia
2017-01-01
The risks of fasting during Ramadan in patients with adrenal insufficiency are unknown. The aims of this study were to evaluate these risks in such patients, to determine the risk factors and finally to set some recommendations. It is a cross-sectional study about 180 patients with known and treated adrenal insufficiency. The patients responded to a 14-item questionnaire concerning their knowledge about the disease and fasting during the last month of Ramadan. There were 132 women and 48 men. The mean age was 47.6 ± 15.0 years (14-79). One hundred and thirty eight patients (76.7 %) were advised by their physician not to fast. Ninety-one patients (50.5 %) tried to fast. Complications occurred in 61 cases (67.0 %): asthenia in 88.5 % of cases, intense thirst in 32.8 %, symptoms of dehydration in 49.2 % and symptoms of hypoglycaemia in 18 %. One patient was hospitalized. Fifty-five patients (60.4 %) were able to fast for the whole month. Age, gender, duration of the disease, its primary origin, associated hypothyroidism, diabetes mellitus, hypertension or diabetes insipidus and daily dose of hydrocortisone did not significantly differ between fasters and non-fasters, full-month-fasters and partial-month-fasters, and fasters with complications and fasters without complications. The frequency of adequate knowledge about the disease was significantly higher in full-month-fasters vs. partial-month-fasters, and in fasters without complications vs. those with complications. In patients with adrenal insufficiency, fasting can cause complications especially if the level of knowledge about the disease is low.
Faster self-paced rate of drinking for alcohol mixed with energy drinks versus alcohol alone.
Marczinski, Cecile A; Fillmore, Mark T; Maloney, Sarah F; Stamates, Amy L
2017-03-01
The consumption of alcohol mixed with energy drinks (AmED) has been associated with higher rates of binge drinking and impaired driving when compared with alcohol alone. However, it remains unclear why the risks of use of AmED are heightened compared with alcohol alone even when the doses of alcohol consumed are similar. Therefore, the purpose of this laboratory study was to investigate if the rate of self-paced beverage consumption was faster for a dose of AmED versus alcohol alone using a double-blind, within-subjects, placebo-controlled study design. Participants (n = 16) of equal gender who were social drinkers attended 4 separate test sessions that involved consumption of alcohol (1.97 ml/kg vodka) and energy drinks, alone and in combination. On each test day, the dose assigned was divided into 10 cups. Participants were informed that they would have a 2-h period to consume the 10 drinks. After the self-paced drinking period, participants completed a cued go/no-go reaction time (RT) task and subjective ratings of stimulation and sedation. The results indicated that participants consumed the AmED dose significantly faster (by ∼16 min) than the alcohol dose. For the performance task, participants' mean RTs were slower in the alcohol conditions and faster in the energy-drink conditions. In conclusion, alcohol consumers should be made aware that rapid drinking might occur for AmED beverages, thus heightening alcohol-related safety risks. The fast rate of drinking may be related to the generalized speeding of responses after energy-drink consumption. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
The repeated-bout effect: influence on biceps brachii oxygenation and myoelectrical activity.
Muthalib, Makii; Lee, Hoseong; Millet, Guillaume Y; Ferrari, Marco; Nosaka, Kazunori
2011-05-01
This study investigated biceps brachii oxygenation and myoelectrical activity during and following maximal eccentric exercise to better understand the repeated-bout effect. Ten men performed two bouts of eccentric exercise (ECC1, ECC2), consisting of 10 sets of 6 maximal lengthening contractions of the elbow flexors separated by 4 wk. Tissue oxygenation index minimum amplitude (TOI(min)), mean and maximum total hemoglobin volume by near-infrared spectroscopy, torque, and surface electromyography root mean square (EMG(RMS)) during exercise were compared between ECC1 and ECC2. Changes in maximal voluntary isometric contraction (MVC) torque, range of motion, plasma creatine kinase activity, muscle soreness, TOI(min), and EMG(RMS) during sustained (10-s) and 30-repeated isometric contraction tasks at 30% (same absolute force) and 100% MVC (same relative force) for 4 days postexercise were compared between ECC1 and ECC2. No significant differences between ECC1 and ECC2 were evident for changes in torque, TOI(min), mean total hemoglobin volume, maximum total hemoglobin volume, and EMG(RMS) during exercise. Smaller (P < 0.05) changes and faster recovery of muscle damage markers were evident following ECC2 than ECC1. During 30% MVC tasks, TOI(min) did not change, but EMG(RMS) increased 1-4 days following ECC1 and ECC2. During 100% MVC tasks, EMG(RMS) did not change, but torque and TOI(min) decreased 1-4 days following ECC1 and ECC2. TOI(min) during 100% MVC tasks and EMG(RMS) during 30% MVC tasks recovered faster (P < 0.05) following ECC2 than ECC1. We conclude that the repeated-bout effect cannot be explained by altered muscle activation or metabolic/hemodynamic changes, and the faster recovery in muscle oxygenation and activation was mainly due to faster recovery of force.
Adrenaline in cardiac arrest: Prefilled syringes are faster.
Helm, Claire; Gillett, Mark
2015-08-01
Standard ampoules and prefilled syringes of adrenaline are widely available in Australasian EDs for use in cardiac arrest. We hypothesise that prefilled syringes can be administered more rapidly and accurately when compared with the two available standard ampoules. This is a triple arm superiority study comparing the time to i.v. administration and accuracy of dosing of three currently available preparations of adrenaline. In their standard packaging, prefilled syringes were on average more than 12 s faster to administer than the 1 mL 1:1000 ampoules and more than 16 s faster than the 10 mL 1:10,000 ampoules (P < 0.01 in both comparisons). With packaging removed, the time to administration was equal for the 1 mL (1:1000) ampoule and the prefilled syringe. Accuracy of dosing was excellent with both the 10 mL (1:10 000) ampoules and prefilled syringes. The 1 mL (1:1000) ampoules delivered a small number of markedly inaccurate doses, but these did not reach statistical significance. The speed of administration of adrenaline utilising a Minijet (CSL Limited, Parkville, Victoria, Australia) is faster than using adrenaline in glass ampoules presented in their plastic packaging. Removing the plastic packaging from the 1 mL (1 mg) ampoule might result in more rapid administration similar to the Minijet. Resuscitation personnel requiring rapid access to adrenaline should consider storing it as either Minijets or ampoules devoid of packaging. These results might be extrapolatable to other clinical scenarios, including pre-hospital and anaesthesia, where other drugs are required for rapid use. © 2015 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Control of a Robotic Hand Using a Tongue Control System-A Prosthesis Application.
Johansen, Daniel; Cipriani, Christian; Popovic, Dejan B; Struijk, Lotte N S A
2016-07-01
The aim of this study was to investigate the feasibility of using an inductive tongue control system (ITCS) for controlling robotic/prosthetic hands and arms. This study presents a novel dual modal control scheme for multigrasp robotic hands combining standard electromyogram (EMG) with the ITCS. The performance of the ITCS control scheme was evaluated in a comparative study. Ten healthy subjects used both the ITCS control scheme and a conventional EMG control scheme to complete grasping exercises with the IH1 Azzurra robotic hand implementing five grasps. Time to activate a desired function or grasp was used as the performance metric. Statistically significant differences were found when comparing the performance of the two control schemes. On average, the ITCS control scheme was 1.15 s faster than the EMG control scheme, corresponding to a 35.4% reduction in the activation time. The largest difference was for grasp 5 with a mean AT reduction of 45.3% (2.38 s). The findings indicate that using the ITCS control scheme could allow for faster activation of specific grasps or functions compared with a conventional EMG control scheme. For transhumeral and especially bilateral amputees, the ITCS control scheme could have a significant impact on the prosthesis control. In addition, the ITCS would provide bilateral amputees with the additional advantage of environmental and computer control for which the ITCS was originally developed.
Amaral, M B F; de Ávila, J M S; Abreu, M H G; Mesquita, R A
2015-11-01
Fibrous hyperplasia is treated by surgical incision using a scalpel, together with removal of the source of chronic trauma. However, scalpel techniques do not provide the haemostasis that is necessary when dealing with highly vascular tissues. Diode laser surgery can be used in the management of oral tissues due to its high absorption by water and haemoglobin, and has provided good results in both periodontal surgery and oral lesions. The aim of the present study was to compare the effects of diode laser surgery to those of the conventional technique in patients with fibrous hyperplasia. A randomized clinical trial was performed in which surgical and postoperative evaluations were analyzed. On comparison of the laser-treated (study group) patients to those treated with a scalpel (control group), significant differences were observed in the duration of surgery and the use of analgesic medications. Over a 3-week period, clinical healing of the postoperative wound was significantly faster in the control group as compared to the study group. In conclusion, diode laser surgery proved to be more effective and less invasive when compared to scalpel surgery in the management of fibrous hyperplasia. However, wound healing proved to be faster when using scalpel surgery. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Corneal wound healing promoted by 3 blood derivatives: an in vitro and in vivo comparative study.
Freire, Vanesa; Andollo, Noelia; Etxebarria, Jaime; Hernáez-Moya, Raquel; Durán, Juan A; Morales, María-Celia
2014-06-01
The aim of this study was to compare the effect on corneal wound healing of 3 differently manufactured blood derivatives [autologous serum (AS), platelet-rich plasma, and serum derived from plasma rich in growth factors (s-PRGF)]. Scratch wound-healing assays were performed on rabbit primary corneal epithelial cultures and human corneal epithelial cells. Additionally, mechanical debridement of rabbit corneal epithelium was performed. Wound-healing progression was assessed by measuring the denuded areas remaining over time after treatment with each of the 3 blood derivatives or a control treatment. In vitro data show statistically significant differences in the healing process with all the derivatives compared with the control, but 2 of them (AS and s-PRGF) induced markedly faster wound healing. In contrast, although the mean time required to complete in vivo reepithelization was similar to that of AS and s-PRGF treatment, only wounds treated with s-PRGF were significantly smaller in size from 2.5 days onward with respect to the control treatment. All 3 blood derivatives studied are promoters of corneal reepithelization. However, the corneal wound-healing progresses differently with each derivative, being faster in vitro under AS and s-PRGF treatment and producing in vivo the greatest decrease in wound size under s-PRGF treatment. These findings highlight that the manufacturing process of the blood derivatives may modulate the efficacy of the final product.
Anatomy of a hash-based long read sequence mapping algorithm for next generation DNA sequencing.
Misra, Sanchit; Agrawal, Ankit; Liao, Wei-keng; Choudhary, Alok
2011-01-15
Recently, a number of programs have been proposed for mapping short reads to a reference genome. Many of them are heavily optimized for short-read mapping and hence are very efficient for shorter queries, but that makes them inefficient or not applicable for reads longer than 200 bp. However, many sequencers are already generating longer reads and more are expected to follow. For long read sequence mapping, there are limited options; BLAT, SSAHA2, FANGS and BWA-SW are among the popular ones. However, resequencing and personalized medicine need much faster software to map these long sequencing reads to a reference genome to identify SNPs or rare transcripts. We present AGILE (AliGnIng Long rEads), a hash table based high-throughput sequence mapping algorithm for longer 454 reads that uses diagonal multiple seed-match criteria, customized q-gram filtering and a dynamic incremental search approach among other heuristics to optimize every step of the mapping process. In our experiments, we observe that AGILE is more accurate than BLAT, and comparable to BWA-SW and SSAHA2. For practical error rates (< 5%) and read lengths (200-1000 bp), AGILE is significantly faster than BLAT, SSAHA2 and BWA-SW. Even for the other cases, AGILE is comparable to BWA-SW and several times faster than BLAT and SSAHA2. http://www.ece.northwestern.edu/~smi539/agile.html.
The Relationship Between Midday Napping And Neurocognitive Function in Early Adolescents.
Ji, Xiaopeng; Li, Junxin; Liu, Jianghong
2018-02-01
The impact of midday napping on neurocognitive function in adolescents has not been well established. This study aimed to investigate the relationship between self-reported midday-napping behaviors and neurocognitive function in early adolescents. The sample was comprised of 363 early adolescents (12.00 ± 0.38 years old) from Jintan, China. Midday napping, nighttime sleep duration, and sleep quality were measured by self-reported questionnaires. Neurocognitive function was measured by the Penn Computerized Neurocognitive Battery (accuracy and reaction times). Generalized linear regression was used to analyze the relationships. Sixty-four percent of our sample took more than 3 naps per week, and 70.11% reported nap durations of over 30 min. Participants with higher frequencies or longer durations of midday napping reported significantly better nighttime sleep quality (p < 0.05). Adjusted models showed that frequent nappers (5-7d/week) were significantly associated with heightened accuracy on tasks that measured sustained attention and nonverbal reasoning and faster reaction times on spatial memory compared with other frequency groups (ps < 0.05). For napping duration subgroups, early adolescents who took naps of any length were estimated to have faster reaction speeds on the sustained attention task compared with participants who never napped (ps < 0.05). However, only nappers with a moderate duration (31-60 min) tended to achieve both faster speeds (β = -38.28, p = 0.02) and better accuracy (β = 3.90, p = 0.04) on the sustained attention task. Our findings suggest that there is an association between habitual midday napping and neurocognitive function in early adolescents, especially in China, where midday napping is a cultural practice.
Caputo, M P; Alphin, R L; Pritchett, E; Hougentogler, D P; Johnson, A L; Benson, E R; Patil, C
2013-02-01
The mass depopulation of production birds remains an effective means of controlling fast-moving, highly infectious diseases such as avian influenza and virulent Newcastle disease. Water-based fire-fighting foam is a conditionally approved method of depopulating floor-reared gallinaceous poultry such as chickens and turkeys; however, ducks have physiological mechanisms that may make them more resistant to this method of depopulation. The following experiment was designed to assess the physiological responses of White Pekin ducks to nonterminal submersion in water-based foam compared with water. The hypothesis of this experiment was that submersion of ducks in water or water-based foam would trigger the diving reflex and lead to bradycardia. All treatments led to pronounced bradycardia. Heart rate was not significantly different between treatments during the final 30 s of the 60-s treatment period. Heart rate dropped significantly faster for the water dip and foam dip treatments and rose significantly faster than the foam pour treatment after the termination of the 60-s treatment period. Duration of bradycardia approached significance for the foam pour treatment, leading to a longer duration of bradycardia compared with the water pour, water dip, and foam dip treatments. The results of this experiment demonstrated that apnea and bradycardia as a result of the diving reflex can occur as a result of submersion in foam, which may have an impact on the time it takes White Pekin ducks to reach unconsciousness and death during water-based foam depopulation.
Kinetic release of hydrogen peroxide from different whitening products.
da Silva Marques, Duarte Nuno; Silveira, Joao Miguel; Marques, Joana Rita; Amaral, Joao Almeida; Guilherme, Nuno Marques; da Mata, António Duarte
2012-01-01
The objective of this in vitro study was to evaluate the kinetics of hydrogen peroxide (HP) release from five different bleaching products: VivaStyle® 10% fitted tray gel, VivaStyle® 30% in-office bleaching gel, VivaStyle® Paint-On Plus paint-on bleaching varnish, Opalescence PF® 10% carbamide peroxide gel and Trèswhite Supreme 10% HP gel. Each product was firstly titrated for its HP content by a described method. HP release kinetics was assessed by a modified spectrophotometric technique. One sample t test was performed to test for differences between the manufacturers' claimed HP concentrations and the titrated HP content in the whitening products. Analysis of variance plus Tamhane's post hoc tests and Pearson correlation analysis were used as appropriate. Values of P < 0.05 were taken as significant. Titrated HP revealed an increased content when compared to the manufacturer's specifications for all the products tested (P < 0.05), although only products from one manufacturer produced significantly higher results. All products presented a significant (P < 0.05) and sustained release of HP. However, the product with paint-on cellulose-based matrix resulted in significantly (P < 0.05) faster kinetics when compared to other products tested. These results are consistent with manufacturers' reduced recommended application times. The results of this study suggest that modifying the matrix composition may be a viable alternative to HP concentration increase, since this may result in faster release kinetics without exposure to high HP concentrations.
Liu, Shawn; Vaillancourt, Christian; Kasaboski, Ann; Taljaard, Monica
2016-11-01
This study sought to measure bystander fatigue and cardiopulmonary resuscitation (CPR) quality after five minutes of CPR using the continuous chest compression (CCC) versus the 30:2 chest compression to ventilation method in older lay persons, a population most likely to perform CPR on cardiac arrest victims. This randomized crossover trial took place at three tertiary care hospitals and a seniors' center. Participants were aged ≥55 years without significant physical limitations (frailty score ≤3/7). They completed two 5-minute CPR sessions (using 30:2 and CCC) on manikins; sessions were separated by a rest period. We used concealed block randomization to determine CPR method order. Metronome feedback maintained a compression rate of 100/minute. We measured heart rate (HR), mean arterial pressure (MAP), and Borg Exertion Scale. CPR quality measures included total number of compressions and number of adequate compressions (depth ≥5 cm). Sixty-three participants were enrolled: mean age 70.8 years, female 66.7%, past CPR training 60.3%. Bystander fatigue was similar between CPR methods: mean difference in HR -0.59 (95% CI -3.51-2.33), MAP 1.64 (95% CI -0.23-3.50), and Borg 0.46 (95% CI 0.07-0.84). Compared to 30:2, participants using CCC performed more chest compressions (480.0 v. 376.3, mean difference 107.7; p<0.0001) and more adequate chest compressions (381.5 v. 324.9, mean difference. 62.0; p=0.0001), although good compressions/minute declined significantly faster with the CCC method (p=0.0002). CPR quality decreased significantly faster when performing CCC compared to 30:2. However, performing CCC produced more adequate compressions overall with a similar level of fatigue compared to the 30:2 method.
Methods for semi-automated indexing for high precision information retrieval.
Berrios, Daniel C; Cucina, Russell J; Fagan, Lawrence M
2002-01-01
To evaluate a new system, ISAID (Internet-based Semi-automated Indexing of Documents), and to generate textbook indexes that are more detailed and more useful to readers. Pilot evaluation: simple, nonrandomized trial comparing ISAID with manual indexing methods. Methods evaluation: randomized, cross-over trial comparing three versions of ISAID and usability survey. Pilot evaluation: two physicians. Methods evaluation: twelve physicians, each of whom used three different versions of the system for a total of 36 indexing sessions. Total index term tuples generated per document per minute (TPM), with and without adjustment for concordance with other subjects; inter-indexer consistency; ratings of the usability of the ISAID indexing system. Compared with manual methods, ISAID decreased indexing times greatly. Using three versions of ISAID, inter-indexer consistency ranged from 15% to 65% with a mean of 41%, 31%, and 40% for each of three documents. Subjects using the full version of ISAID were faster (average TPM: 5.6) and had higher rates of concordant index generation. There were substantial learning effects, despite our use of a training/run-in phase. Subjects using the full version of ISAID were much faster by the third indexing session (average TPM: 9.1). There was a statistically significant increase in three-subject concordant indexing rate using the full version of ISAID during the second indexing session (p < 0.05). Users of the ISAID indexing system create complex, precise, and accurate indexing for full-text documents much faster than users of manual methods. Furthermore, the natural language processing methods that ISAID uses to suggest indexes contributes substantially to increased indexing speed and accuracy.
Kruimel, J W; Naber, A H; Curfs, J H; Wenker, M A; Jansen, J B
2000-01-01
Parenteral lipid emulsions are suspected of suppressing the immune function. However, study results are contradictory and mainly concern the conventional long-chain triglyceride emulsions. Polymorphonuclear leukocytes were preincubated with parenteral lipid emulsions. The influence of the lipid emulsions on the production of oxygen radicals by these stimulated leukocytes was studied by measuring chemiluminescence. Three different parenteral lipid emulsions were tested: long-chain triglycerides, a physical mixture of medium- and long-chain triglycerides, and structured triglycerides. Structured triglycerides consist of triglycerides where the medium- and long-chain fatty acids are attached to the same glycerol molecule. Stimulated polymorphonuclear leukocytes preincubated with the physical mixture of medium- and long-chain triglycerides showed higher levels of oxygen radicals (p < .005) and faster production of oxygen radicals (p < .005) compared with polymorphonuclear leukocytes preincubated with long-chain triglycerides or structured triglycerides. Additional studies indicated that differences in results of various lipid emulsions were not caused by differences in emulsifier. The overall production of oxygen radicals was significantly lower after preincubation with the three lipid emulsions compared with controls without lipid emulsion. A physical mixture of medium- and long-chain triglycerides induced faster production of oxygen radicals, resulting in higher levels of oxygen radicals, compared with long-chain triglycerides or structured triglycerides. This can be detrimental in cases where oxygen radicals play either a pathogenic role or a beneficial one, such as when rapid phagocytosis and killing of bacteria is needed. The observed lower production of oxygen radicals by polymorphonuclear leukocytes in the presence of parenteral lipid emulsions may result in immunosuppression by these lipids.
Niederauer, Mark Q; Michalek, Joel E; Armstrong, David G
2017-09-01
Over the past generation, preclinical data have suggested that there is a potential physiologic benefit to applying oxygen topically to wounds. However, we are unaware of any studies in the literature that have robustly assessed whether this would lead to a higher proportion of healing in similarly treated people without oxygen. Therefore, the purpose of this study was to assess this in people being treated for chronic diabetic foot ulcers (DFUs). We enrolled and randomized 100 subjects with DFUs (79% male, aged 58.3 ± 12.1 years) to receive either active continuous diffusion of oxygen (CDO) therapy using an active CDO device, or an otherwise fully operational sham device that provided moist wound therapy (MWT) without delivering oxygen. Patients were followed until closure or 12 weeks, whichever was sooner. Patients, treating physicians and independent evaluators were blinded to the study arm. All patients received identical offloading, dressings and follow-up. There were no significant differences in assessed descriptive characteristics between the treatment arms ( P > .05 for all). A significantly higher proportion of people healed in the active arm compared to sham (46% vs 22%, P = .02). This relative effect became greater in more chronic wounds (42.5% vs 13.5%, P = .006). Patients randomized to the active device experienced significantly faster rates of closure relative to the sham ( P < .001). The results of this study suggest that continuously diffused oxygen over a wound leads to significantly higher rates of closure, and faster time to closure, compared to similarly treated patients receiving standard therapy coupled with a sham device. Furthermore, the relative efficacy appears to improve the more the therapy may be needed (more chronic and larger wounds).
Nusstein, John; Wood, Mark; Reader, Al; Beck, Mike; Weaver, Joel
2005-01-01
This prospective, randomized study compared the degree of pulpal anesthesia obtained from an intraosseous injection to an infiltration injection that used 2% lidocaine with 1:100,000 epinephrine. The success rate for the intraosseous injection was 98%; for the infiltration injection, the success rate was 85%. There was no significant difference between the two techniques. The mean time for the onset of pulpal anesthesia was significantly faster with the intraosseous injection and the infiltration injection resulted in a significantly longer duration of pulpal anesthesia.
The relationship between session frequency and psychotherapy outcome in a naturalistic setting.
Erekson, David M; Lambert, Michael J; Eggett, Dennis L
2015-12-01
The dose-response relationship in psychotherapy has been examined extensively, but few studies have included session frequency as a component of psychotherapy "dose." Studies that have examined session frequency have indicated that it may affect both the speed and the amount of recovery. No studies were found examining the clinical significance of this construct in a naturalistic setting, which is the aim of the current study. Using an archival database of session-by-session Outcome Questionnaire 45 (OQ-45) measures over 17 years, change trajectories of 21,488 university counseling center clients (54.9% female, 85.0% White, mean age = 22.5) were examined using multilevel modeling, including session frequency at the occasion level. Of these clients, subgroups that attended therapy approximately weekly or fortnightly were compared to each other for differences in speed of recovery (using multilevel Cox regression) and clinically significant change (using multilevel logistic regression). Results indicated that more frequent therapy was associated with steeper recovery curves (Cohen's f2 = 0.07; an effect size between small and medium). When comparing weekly and fortnightly groups, clinically significant gains were achieved faster for those attending weekly sessions; however, few significant differences were found between groups in total amount of change in therapy. Findings replicated previous session frequency literature and supported a clinically significant effect, where higher session frequency resulted in faster recovery. Session frequency appears to be an impactful component in delivering more efficient psychotherapy, and it is important to consider in individual treatment planning, institutional policy, and future research. (c) 2015 APA, all rights reserved).
Seiss, M; Gahr, A; Niessner, R
2001-09-01
In this article, the wastewater treatment by UV oxidation with and without preceding desalination is compared. The influence of different chloride concentrations on the TOC degradation and AOX concentration is analyzed. Nanofiltration membrane dialysis is used to separate the chloride ions from wastewater. It is demonstrated that a reduction of the chloride concentration leads to a faster TOC degradation compared to the treatment of non-desalinated wastewater. Furthermore, the additional formation of AOX during the process could be avoided in effect leading to a significant degradation of native AOX.
A comparison of microwave versus direct solar heating for lunar brick production
NASA Technical Reports Server (NTRS)
Yankee, S. J.; Strenski, D. G.; Pletka, B. J.; Patil, D. S.; Mutsuddy, B. C.
1990-01-01
Two processing techniques considered suitable for producing bricks from lunar regolith are examined: direct solar heating and microwave heating. An analysis was performed to compare the two processes in terms of the amount of power and time required to fabricate bricks of various sizes. Microwave heating was shown to be significantly faster than solar heating for rapid production of realistic-size bricks. However, the relative simplicity of the solar collector(s) used for the solar furnace compared to the equipment necessary for microwave generation may present an economic tradeoff.
A leap forward with UTK s Cray XC30
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fahey, Mark R
2014-01-01
This paper shows a significant productivity leap for several science groups and the accomplishments they have made to date on Darter - a Cray XC30 at the University of Tennessee Knoxville. The increased productivity is due to faster processors and interconnect combined in a new generation from Cray, and yet it still has a very similar programming environment as compared to previous generations of Cray machines that makes porting easy.
Looking and touching: What extant approaches reveal about the structure of early word knowledge
Hendrickson, Kristi; Mitsven, Samantha; Poulin-Dubois, Diane; Zesiger, Pascal; Friend, Margaret
2014-01-01
The goal of the current study is to assess the temporal dynamics of vision and action to evaluate the underlying word representations that guide infants’ responses. Sixteen-month-old infants participated in a two-alternative forced-choice word-picture matching task. We conducted a moment-by-moment analysis of looking and reaching behaviors as they occurred in tandem to assess the speed with which a prompted word was processed (visual reaction time) as a function of the type of haptic response: Target, Distractor, or No Touch. Visual reaction times (visual RTs) were significantly slower during No Touches compared to Distractor and Target Touches, which were statistically indistinguishable. The finding that visual RTs were significantly faster during Distractor Touches compared to No Touches suggests that incorrect and absent haptic responses appear to index distinct knowledge states: incorrect responses are associated with partial knowledge whereas absent responses appear to reflect a true failure to map lexical items to their target referents. Further, we found that those children who were faster at processing words were also those children who exhibited better haptic performance. This research provides a methodological clarification on knowledge measured by the visual and haptic modalities and new evidence for a continuum of word knowledge in the second year of life. PMID:25444711
Faster acquisition of laparoscopic skills in virtual reality with haptic feedback and 3D vision.
Hagelsteen, Kristine; Langegård, Anders; Lantz, Adam; Ekelund, Mikael; Anderberg, Magnus; Bergenfelz, Anders
2017-10-01
The study investigated whether 3D vision and haptic feedback in combination in a virtual reality environment leads to more efficient learning of laparoscopic skills in novices. Twenty novices were allocated to two groups. All completed a training course in the LapSim ® virtual reality trainer consisting of four tasks: 'instrument navigation', 'grasping', 'fine dissection' and 'suturing'. The study group performed with haptic feedback and 3D vision and the control group without. Before and after the LapSim ® course, the participants' metrics were recorded when tying a laparoscopic knot in the 2D video box trainer Simball ® Box. The study group completed the training course in 146 (100-291) minutes compared to 215 (175-489) minutes in the control group (p = .002). The number of attempts to reach proficiency was significantly lower. The study group had significantly faster learning of skills in three out of four individual tasks; instrument navigation, grasping and suturing. Using the Simball ® Box, no difference in laparoscopic knot tying after the LapSim ® course was noted when comparing the groups. Laparoscopic training in virtual reality with 3D vision and haptic feedback made training more time efficient and did not negatively affect later video box-performance in 2D. [Formula: see text].
Campos, José Luis; Johnston, Keira; Charlesworth, Brian
2017-12-08
A faster rate of adaptive evolution of X-linked genes compared with autosomal genes (the faster-X effect) can be caused by the fixation of recessive or partially recessive advantageous mutations. This effect should be largest for advantageous mutations that affect only male fitness, and least for mutations that affect only female fitness. We tested these predictions in Drosophila melanogaster by using coding and functionally significant non-coding sequences of genes with different levels of sex-biased expression. Consistent with theory, nonsynonymous substitutions in most male-biased and unbiased genes show faster adaptive evolution on the X. However, genes with very low recombination rates do not show such an effect, possibly as a consequence of Hill-Robertson interference. Contrary to expectation, there was a substantial faster-X effect for female-biased genes. After correcting for recombination rate differences, however, female-biased genes did not show a faster X-effect. Similar analyses of non-coding UTRs and long introns showed a faster-X effect for all groups of genes, other than introns of female-biased genes. Given the strong evidence that deleterious mutations are mostly recessive or partially recessive, we would expect a slower rate of evolution of X-linked genes for slightly deleterious mutations that become fixed by genetic drift. Surprisingly, we found little evidence for this after correcting for recombination rate, implying that weakly deleterious mutations are mostly close to being semidominant. This is consistent with evidence from polymorphism data, which we use to test how models of selection that assume semidominance with no sex-specific fitness effects may bias estimates of purifying selection. © The Author 2017. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Articulation rate across dialect, age, and gender
Jacewicz, Ewa; Fox, Robert A.; O’Neill, Caitlin; Salmons, Joseph
2009-01-01
The understanding of sociolinguistic variation is growing rapidly, but basic gaps still remain. Whether some languages or dialects are spoken faster or slower than others constitutes such a gap. Speech tempo is interconnected with social, physical and psychological markings of speech. This study examines regional variation in articulation rate and its manifestations across speaker age, gender and speaking situations (reading vs. free conversation). The results of an experimental investigation show that articulation rate differs significantly between two regional varieties of American English examined here. A group of Northern speakers (from Wisconsin) spoke significantly faster than a group of Southern speakers (from North Carolina). With regard to age and gender, young adults read faster than older adults in both regions; in free speech, only Northern young adults spoke faster than older adults. Effects of gender were smaller and less consistent; men generally spoke slightly faster than women. As the body of work on the sociophonetics of American English continues to grow in scope and depth, we argue that it is important to include fundamental phonetic information as part of our catalog of regional differences and patterns of change in American English. PMID:20161445
Sappey-Marinier, Dominique; Chileuitt, Laureano; Weiner, Michael W.; Faden, Alan I.; Weinstein, Philip R.
2009-01-01
Sequential 31P and 1H MRS was used to measure cerebral phosphate metabolites, intracellular pH, and lactate in normoglycemic and hypoglycemic rats during 30 min of complete cerebral ischemia and 5.5 h of reperfusion. These results were correlated with brain levels of free fatty acids (FFAs), excitatory amino acids, cations, and water content at death. The lactate/N-acetyl aspartate ratio was not significantly different between groups before or during occlusion. During reperfusion, the ratio was higher in normoglycemic rats from 3 to 85 min (p≤ 0.05), and recovery time was faster in hypoglycemic rats (29 vs 45 min; p = 0.04), suggesting reduced lactate production and faster recovery of aerobic metabolism. During occlusion, significant but comparable decrease of intracellular pH occurred in each group. Intracellular pH was higher in hypoglycemic rats at 140 min and 260 min of reperfusion. Water content, Na and K+ concentrations, and FFA and excitatory amino acid levels were not significantly different between groups, but hypoglycemic rats had less depletion of levels of Mg2+ (p=0.011). These results show that hypoglycemia has a limited but potentially beneficial effect on postischemic lactic acidosis. PMID:8771092
Wang, Xue-Min; Zhu, Yan-Ping; Wang, Li
2013-12-01
To investigate the effects of positive nutritional support in the early stage after birth on the nutritional status during hospitalization and extrauterine growth restriction (EUGR) in preterm infants. There were two groups of preterm infants. Group A (n=99) was given the previous nutritional program, while group B (n=101) was given positive nutritional support. The nutritional intake, growth rate and EUGR incidence were compared between the two groups. Compared with group A, group B had significantly higher enteral calorie intake and total calorie intake within one week after birth. Additionally, the age of first feeding, time of regaining birth weight, duration of intravenous nutrition, time to full enteral feeding, and length of hospital stay in group B were all shorter than in group A. Group B also had less physiological weight loss than group A. Among the preterm infants with a gestational age less than 32 weeks, group B had faster increases in body weight, head circumference, and body length and a lower incidence of EUGR compared with group A. Among the preterm infants with a gestational age not less than 32 weeks, group B had faster increases in body weight and a lower incidence of EUGR (evaluated based on body weight and head circumference) compared with group A. During hospitalization, group B had significantly lower incidence of feeding intolerance, necrotizing enterocolitis, and sepsis than group A. Positive nutritional support strategy, applied in preterm infants early after birth, can effectively improve their nutritional status during hospitalization and reduce the incidence of EUGR without increasing the incidence of related complications during hospitalization.
Peacock, Zachary S.; Tricomi, Brad; Murphy, Brian; Magill, John; Kaban, Leonard B.; Troulis, Maria
2013-01-01
Purpose To determine if automated continuous distraction osteogenesis at rates > 1mm/day would result in clinical and radiographic bone formation in a minipig model. Materials and Methods An automated, continuous, curvilinear distraction device was placed across a mandibular osteotomy in 10 minipigs. After 12 mm of distraction and 24 days fixation, animals were sacrificed and bone healing evaluated. The continuous distraction rates were 1.5 (n=5) and 3 mm/day (n=5). A semiquantitative scale was used to assess ex-vivo clinical appearance of the distraction gap (3= osteotomy not visible; 2= <50%; 1= >50%; 0= 100% visible); stability (3 = no mobility; 2 and 1 = mobility in 2 or 1 plane respectively; 0= mobility in 3 planes); radiographic density (4 = 100% gap opaque, 3= >75%, 2 = 50% – 75%, 1= <50%, or 0 = radiolucent). Groups of 4 minipigs distracted discontinuously at 1, 2, and 4 mm/day served as controls. Results The continuous DO 1.5 mm/day group had significantly higher scores for appearance and radiographic density compared to the discontinuous 4 mm/day group. The continuous DO 3mm/day group had significantly higher scores for appearance and radiographic density compared to the discontinuous 4 mm/day group, and higher stability compared to the discontinuous 2 and 4 mm/day groups. Conclusions Results of this preliminary study indicate that continuous DO at rates of 1.5 and 3.0 mm/day produces better bone formation when compared to discontinuous DO at rates faster than 1mm/day. PMID:23499159
Niaura, Raymond; Sayette, Michael; Shiffman, Saul; Glover, Elbert D; Nides, Mitch; Shelanski, Morris; Shadel, William; Koslo, Randy; Robbins, Bruce; Sorrentino, Jim
2005-11-01
Most relapse episodes occur when smokers are confronted with craving provoked by situational cues. Current nicotine gum can help relieve cue-provoked cravings, but faster effects may result in more rapid relief. We tested a prototype formulation of a new rapid-release nicotine gum (RRNG) that provides more rapid release and absorption of nicotine, for its ability to provide faster and better craving relief compared to current nicotine polacrilex gum (NPG). Random assignment to RRNG or NPG, used during a smoking cue provocation procedure. Participants and setting A total of 319 smokers were exposed to a smoking cue in the laboratory by being asked to light but not smoke a cigarette of their preferred brand. Subjects then chewed a piece of 2 mg RRNG (n = 159) or 2 mg NPG (n = 160) according to randomized assignment. Craving assessments were completed at regular intervals before and after cue exposure (baseline, pre-cue, and 3, 6, 9, 12, 15, 18, 21, 25, 30 and 35 minutes after the cue). Smokers chewing RRNG showed significantly lower craving than NPG subjects starting with the first assessment at 3 minutes (P < 0.025). Repeated-measures ANOVA revealed a significant treatment x time interaction (P < 0.05)-craving scores dropped more rapidly in RRNG subjects compared to NPG subjects. Survival analyses also indicated superiority of RRNG in achieving more rapid self-reported meaningful relief (P < 0.05) and complete relief (P < 0.05) of craving. Rapid-release nicotine gum reduced cue-provoked craving more rapidly compared to NPG, and thus merits further study in cessation efficacy trials.
RAPSearch: a fast protein similarity search tool for short reads
2011-01-01
Background Next Generation Sequencing (NGS) is producing enormous corpuses of short DNA reads, affecting emerging fields like metagenomics. Protein similarity search--a key step to achieve annotation of protein-coding genes in these short reads, and identification of their biological functions--faces daunting challenges because of the very sizes of the short read datasets. Results We developed a fast protein similarity search tool RAPSearch that utilizes a reduced amino acid alphabet and suffix array to detect seeds of flexible length. For short reads (translated in 6 frames) we tested, RAPSearch achieved ~20-90 times speedup as compared to BLASTX. RAPSearch missed only a small fraction (~1.3-3.2%) of BLASTX similarity hits, but it also discovered additional homologous proteins (~0.3-2.1%) that BLASTX missed. By contrast, BLAT, a tool that is even slightly faster than RAPSearch, had significant loss of sensitivity as compared to RAPSearch and BLAST. Conclusions RAPSearch is implemented as open-source software and is accessible at http://omics.informatics.indiana.edu/mg/RAPSearch. It enables faster protein similarity search. The application of RAPSearch in metageomics has also been demonstrated. PMID:21575167
Hontanilla, Bernardo; Marré, Diego
2012-11-01
Masseteric and hypoglossal nerve transfers are reliable alternatives for reanimating short-term facial paralysis. To date, few studies exist in the literature comparing these techniques. This work presents a quantitative comparison of masseter-facial transposition versus hemihypoglossal facial transposition with a nerve graft using the Facial Clima system. Forty-six patients with complete unilateral facial paralysis underwent reanimation with either hemihypoglossal transposition with a nerve graft (group I, n = 25) or direct masseteric-facial coaptation (group II, n = 21). Commissural displacement and commissural contraction velocity were measured using the Facial Clima system. Postoperative intragroup commissural displacement and commissural contraction velocity means of the reanimated versus the normal side were first compared using a paired sample t test. Then, mean percentages of recovery of both parameters were compared between the groups using an independent sample t test. Onset of movement was also compared between the groups. Significant differences of mean commissural displacement and commissural contraction velocity between the reanimated side and the normal side were observed in group I but not in group II. Mean percentage of recovery of both parameters did not differ between the groups. Patients in group II showed a significantly faster onset of movement compared with those in group I (62 ± 4.6 days versus 136 ± 7.4 days, p = 0.013). Reanimation of short-term facial paralysis can be satisfactorily addressed by means of either hemihypoglossal transposition with a nerve graft or direct masseteric-facial coaptation. However, with the latter, better symmetry and a faster onset of movement are observed. In addition, masseteric nerve transfer avoids morbidity from nerve graft harvesting. Therapeutic, III.
Vivas, David; Martín, Agustín; Bernardo, Esther; Ortega-Pozzi, María Aranzazu; Tirado, Gabriela; Fernández, Cristina; Vilacosta, Isidre; Núñez-Gil, Iván; Macaya, Carlos; Fernández-Ortiz, Antonio
2015-05-01
Prasugrel and ticagrelor, new P2Y12-adenosine diphosphate receptor antagonists, are associated with greater pharmacodynamic inhibition and reduction of cardiovascular events compared with clopidogrel in patients with an acute coronary syndrome. However, evidence is lacking about the effects of achieving faster and stronger cyclooxygenase inhibition with intravenous lysine acetylsalicylate (LA) compared with oral aspirin on prasugrel-inhibited platelets. This was a prospective, randomized, single-center, open, 2-period crossover platelet function study conducted in 30 healthy volunteers. Subjects were randomly assigned to receive a loading dose of intravenous LA 450 mg plus oral prasugrel 60 mg or loading dose of aspirin 300 mg plus prasugrel 60 mg orally in a crossover fashion after a 2-week washout period between treatments. Platelet function was evaluated at baseline, 30 minutes, 1 h, 4 h, and 24 h using light transmission aggregometry and vasodilator-stimulated phosphoprotein phosphorylation. The primary end point of the study, inhibition of platelet aggregation after arachidonic acid 1.5 mmol/L at 30 minutes, was significantly higher in subjects treated with LA compared with aspirin: 85.3% versus 44.3%, respectively, P=0.003. This differential effect was observed at 1 hour (P=0.002) and 4 hours (P=0.048), but not at 24 hours. Subjects treated with LA presented less variability and faster and greater inhibition of platelet aggregation with arachidonic acid compared with aspirin. The administration of intravenous LA resulted in a significant reduction of platelet reactivity compared with oral aspirin on prasugrel-inhibited platelets. Loading dose of LA achieves an earlier platelet inhibition and with less variability than aspirin. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02243137. © 2015 American Heart Association, Inc.
Anand, Sarah; Thomas, Samantha; Hyslop, Terry; Adcock, Janet; Corbet, Kelly; Gasparetto, Cristina; Lopez, Richard; Long, Gwynn D; Morris, Ashley K; Rizzieri, David A; Sullivan, Keith M; Sung, Anthony D; Sarantopoulos, Stefanie; Chao, Nelson J; Horwitz, Mitchell E
2017-07-01
Delayed hematopoietic recovery contributes to increased infection risk following umbilical cord blood (UCB) transplantation. In a Phase 1 study, adult recipients of UCB stem cells cultured ex vivo for 3 weeks with nicotinamide (NiCord) had earlier median neutrophil recovery compared with historical controls. To evaluate the impact of faster neutrophil recovery on clinically relevant early outcomes, we reviewed infection episodes and hospitalization during the first 100 days in an enlarged cohort of 18 NiCord recipients compared with 86 standard UCB recipients at our institution. The median time to neutrophil engraftment was shorter in NiCord recipients compared with standard UCB recipients (12.5 days versus 26 days; P < .001). Compared with standard UCB recipients, NiCord recipients had a significantly reduced risk for total infection (RR, 0.69; P = .01), grade 2-3 (moderate to severe) infection (RR, 0.36; P < .001), bacterial infection (RR, 0.39; P = .003), and grade 2-3 bacterial infection (RR, 0.21; P = .003) by Poisson regression analysis; this effect persisted after adjustment for age, disease stage, and grade II-IV acute GVHD. NiCord recipients also had significantly more time out of the hospital in the first 100 days post-transplantation after adjustment for age and Karnofsky Performance Status (69.9 days versus 49.7 days; P = .005). Overall, transplantation of NiCord was associated with faster neutrophil engraftment, fewer total and bacterial infections, and shorter hospitalization in the first 100 days compared with standard UCB transplantation. In conclusion, rapid hematopoietic recovery from an ex vivo expanded UCB transplantation approach is associated with early clinical benefit. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Peak, J N; Turner, K M; Burne, T H J
2015-01-01
Developmental vitamin D (DVD) deficiency is a plausible risk factor for schizophrenia that has been associated with behavioural alterations including disruptions in latent inhibition and response inhibition. The rodent gambling task (rGT) assesses risk-based decision-making, which is a key cognitive deficit observed in schizophrenia patients. The primary aim of this study was to examine risk-based decision-making in DVD-deficient and control rats on the rGT. We also evaluated the performance of female Sprague-Dawley rats on the rGT for the first time. Adult male and female Sprague-Dawley rats from control and vitamin D deficient dams were trained to perform the rGT in standard operant chambers and their performance and choice-preferences were assessed. Female rats were significantly faster to reach rGT training criteria compared with male rats and DVD-deficient rats were faster to reach training criteria than control animals. After reaching stable performance on the rGT DVD-deficient and control rats showed a significant preference for the optimal choice-option in the rGT, but there were no significant effects of sex or diet on these responses. DVD deficiency did not alter the decision-making processes on the rGT because no significant changes in choice-preferences were evident. This is the first study to demonstrate that once established, the performance of females is comparable to male Sprague-Dawley rats on the rGT. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.
Optimal knockout strategies in genome-scale metabolic networks using particle swarm optimization.
Nair, Govind; Jungreuthmayer, Christian; Zanghellini, Jürgen
2017-02-01
Knockout strategies, particularly the concept of constrained minimal cut sets (cMCSs), are an important part of the arsenal of tools used in manipulating metabolic networks. Given a specific design, cMCSs can be calculated even in genome-scale networks. We would however like to find not only the optimal intervention strategy for a given design but the best possible design too. Our solution (PSOMCS) is to use particle swarm optimization (PSO) along with the direct calculation of cMCSs from the stoichiometric matrix to obtain optimal designs satisfying multiple objectives. To illustrate the working of PSOMCS, we apply it to a toy network. Next we show its superiority by comparing its performance against other comparable methods on a medium sized E. coli core metabolic network. PSOMCS not only finds solutions comparable to previously published results but also it is orders of magnitude faster. Finally, we use PSOMCS to predict knockouts satisfying multiple objectives in a genome-scale metabolic model of E. coli and compare it with OptKnock and RobustKnock. PSOMCS finds competitive knockout strategies and designs compared to other current methods and is in some cases significantly faster. It can be used in identifying knockouts which will force optimal desired behaviors in large and genome scale metabolic networks. It will be even more useful as larger metabolic models of industrially relevant organisms become available.
Hsu, Ju-Wei; Su, Tung-Ping; Huang, Chen-Ying; Chen, Ying-Sheue; Chou, Yuan-Hwa
2011-10-01
Several previous studies, including a meta-analysis, reported no significant differences between various selective serotonin reuptake inhibitors (SSRIs) in the treatment of major depressive disorder. However, because of the different chemical structure of SSRIs and the difference in the frequency of serotonin transporter polymorphisms between ethnic groups, a head-to-head comparative study between SSRIs in different populations may be enlightening. We compared the efficacy and adverse effect profiles of citalopram and sertraline in a double-blinded randomized clinical trial in a Chinese population of drug-naïve patients with first-episode major depressive disorder. Fifty-one patients were randomly assigned to citalopram or sertraline treatment. The Montgomery-Åsberg Depression Rating Scale (MADRS) was used as the primary outcome. Efficacy and adverse effects were analyzed in an intent-to-treat population. Efficacy was analyzed using a last-observation-carried-forward method for early terminators. There were no significant differences in demographic characteristics at baseline. No significant differences were found in MADRS scores between citalopram and sertraline at baseline (36.6 ± 5.5 vs 38.2 ± 4.9; P = 0.322) or at the end of treatment (week 6; 10.8 ± 10.0 vs 16.7 ± 11.3; P = 0.082). However, MADRS scores in the citalopram group were significantly lower at week 1 (25.2 ± 8.5 vs 30.4 ± 6.1; P = 0.029) and week 3 (15.9 ± 10.0 vs 22.1 ± 8.7; P = 0.037). Overall, treatment-emergent adverse effects were reported by 14.3% and 28.6% of patients in the citalopram and sertraline groups, respectively. In conclusion, citalopram and sertraline were both efficacious and well tolerated. However, citalopram exhibited a significantly faster onset than sertraline during the early weeks of treatment and tended to have a better efficacy in overall treatment, although the statistic was not significant.
Looming auditory collision warnings for driving.
Gray, Rob
2011-02-01
A driving simulator was used to compare the effectiveness of increasing intensity (looming) auditory warning signals with other types of auditory warnings. Auditory warnings have been shown to speed driver reaction time in rear-end collision situations; however, it is not clear which type of signal is the most effective. Although verbal and symbolic (e.g., a car horn) warnings have faster response times than abstract warnings, they often lead to more response errors. Participants (N=20) experienced four nonlooming auditory warnings (constant intensity, pulsed, ramped, and car horn), three looming auditory warnings ("veridical," "early," and "late"), and a no-warning condition. In 80% of the trials, warnings were activated when a critical response was required, and in 20% of the trials, the warnings were false alarms. For the early (late) looming warnings, the rate of change of intensity signaled a time to collision (TTC) that was shorter (longer) than the actual TTC. Veridical looming and car horn warnings had significantly faster brake reaction times (BRT) compared with the other nonlooming warnings (by 80 to 160 ms). However, the number of braking responses in false alarm conditions was significantly greater for the car horn. BRT increased significantly and systematically as the TTC signaled by the looming warning was changed from early to veridical to late. Looming auditory warnings produce the best combination of response speed and accuracy. The results indicate that looming auditory warnings can be used to effectively warn a driver about an impending collision.
Methods for semi-automated indexing for high precision information retrieval
NASA Technical Reports Server (NTRS)
Berrios, Daniel C.; Cucina, Russell J.; Fagan, Lawrence M.
2002-01-01
OBJECTIVE: To evaluate a new system, ISAID (Internet-based Semi-automated Indexing of Documents), and to generate textbook indexes that are more detailed and more useful to readers. DESIGN: Pilot evaluation: simple, nonrandomized trial comparing ISAID with manual indexing methods. Methods evaluation: randomized, cross-over trial comparing three versions of ISAID and usability survey. PARTICIPANTS: Pilot evaluation: two physicians. Methods evaluation: twelve physicians, each of whom used three different versions of the system for a total of 36 indexing sessions. MEASUREMENTS: Total index term tuples generated per document per minute (TPM), with and without adjustment for concordance with other subjects; inter-indexer consistency; ratings of the usability of the ISAID indexing system. RESULTS: Compared with manual methods, ISAID decreased indexing times greatly. Using three versions of ISAID, inter-indexer consistency ranged from 15% to 65% with a mean of 41%, 31%, and 40% for each of three documents. Subjects using the full version of ISAID were faster (average TPM: 5.6) and had higher rates of concordant index generation. There were substantial learning effects, despite our use of a training/run-in phase. Subjects using the full version of ISAID were much faster by the third indexing session (average TPM: 9.1). There was a statistically significant increase in three-subject concordant indexing rate using the full version of ISAID during the second indexing session (p < 0.05). SUMMARY: Users of the ISAID indexing system create complex, precise, and accurate indexing for full-text documents much faster than users of manual methods. Furthermore, the natural language processing methods that ISAID uses to suggest indexes contributes substantially to increased indexing speed and accuracy.
Methods for Semi-automated Indexing for High Precision Information Retrieval
Berrios, Daniel C.; Cucina, Russell J.; Fagan, Lawrence M.
2002-01-01
Objective. To evaluate a new system, ISAID (Internet-based Semi-automated Indexing of Documents), and to generate textbook indexes that are more detailed and more useful to readers. Design. Pilot evaluation: simple, nonrandomized trial comparing ISAID with manual indexing methods. Methods evaluation: randomized, cross-over trial comparing three versions of ISAID and usability survey. Participants. Pilot evaluation: two physicians. Methods evaluation: twelve physicians, each of whom used three different versions of the system for a total of 36 indexing sessions. Measurements. Total index term tuples generated per document per minute (TPM), with and without adjustment for concordance with other subjects; inter-indexer consistency; ratings of the usability of the ISAID indexing system. Results. Compared with manual methods, ISAID decreased indexing times greatly. Using three versions of ISAID, inter-indexer consistency ranged from 15% to 65% with a mean of 41%, 31%, and 40% for each of three documents. Subjects using the full version of ISAID were faster (average TPM: 5.6) and had higher rates of concordant index generation. There were substantial learning effects, despite our use of a training/run-in phase. Subjects using the full version of ISAID were much faster by the third indexing session (average TPM: 9.1). There was a statistically significant increase in three-subject concordant indexing rate using the full version of ISAID during the second indexing session (p < 0.05). Summary. Users of the ISAID indexing system create complex, precise, and accurate indexing for full-text documents much faster than users of manual methods. Furthermore, the natural language processing methods that ISAID uses to suggest indexes contributes substantially to increased indexing speed and accuracy. PMID:12386114
X-ray-induced changes in growth of Mozambique tilapia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jana, B.B.; Basu, M.
1995-01-01
Early fry (30 d postfertilization) and 7-8-week-old Mozambique tilapias (Tilapia mossambica) were exposed to X rays in dosages of 50, 100, 200, 300, 400 or 500 roentgens and reared in outdoor culture tanks between May 1981 and October 1988. Fish of either sex that were irradiated as fry grew faster than controls at all test X-ray doses. Among fish irradiated at 7-8 weeks, males grew significantly faster, but females grew significantly slower, than controls at all test doses. X-ray-induced changes in growth were dose-dependent: growth rates of fry (both sexes) and of juvenile males rose relative to those of controlsmore » with increased radiation dose. The growth increase per unit of radiation dose was higher for fry than for older juveniles. The length-weight regression was steeper for irradiated males than for controls. The average weights of F{sub 1} offspring of irradiated fish were greatly reduced as compared with controls, which suggests the transfer of the detrimental effects of X rays from irradiated parents to their offspring. 39 refs., 3 figs., 3 tabs.« less
Faster-X Evolution of Gene Expression in Drosophila
Meisel, Richard P.; Malone, John H.; Clark, Andrew G.
2012-01-01
DNA sequences on X chromosomes often have a faster rate of evolution when compared to similar loci on the autosomes, and well articulated models provide reasons why the X-linked mode of inheritance may be responsible for the faster evolution of X-linked genes. We analyzed microarray and RNA–seq data collected from females and males of six Drosophila species and found that the expression levels of X-linked genes also diverge faster than autosomal gene expression, similar to the “faster-X” effect often observed in DNA sequence evolution. Faster-X evolution of gene expression was recently described in mammals, but it was limited to the evolutionary lineages shortly following the creation of the therian X chromosome. In contrast, we detect a faster-X effect along both deep lineages and those on the tips of the Drosophila phylogeny. In Drosophila males, the dosage compensation complex (DCC) binds the X chromosome, creating a unique chromatin environment that promotes the hyper-expression of X-linked genes. We find that DCC binding, chromatin environment, and breadth of expression are all predictive of the rate of gene expression evolution. In addition, estimates of the intraspecific genetic polymorphism underlying gene expression variation suggest that X-linked expression levels are not under relaxed selective constraints. We therefore hypothesize that the faster-X evolution of gene expression is the result of the adaptive fixation of beneficial mutations at X-linked loci that change expression level in cis. This adaptive faster-X evolution of gene expression is limited to genes that are narrowly expressed in a single tissue, suggesting that relaxed pleiotropic constraints permit a faster response to selection. Finally, we present a conceptional framework to explain faster-X expression evolution, and we use this framework to examine differences in the faster-X effect between Drosophila and mammals. PMID:23071459
Bhaskar, Anusha; Nithya, V.
2012-01-01
Objective: To investigate the wound-healing potency of the ethanolic extract of the flowers of Hibiscus rosa sinensis. Materials and Methods: The wound-healing activity of H. rosa sinensis (5 and 10% w/w) on Wistar albino rats was studied using three different models viz., excision, incision and dead space wound. The parameters studied were breaking strength in incision model, granulation tissue dry weight, breaking strength and collagen content in dead space wound model, percentage of wound contraction and period of epithelization in excision wound model. The granulation tissue formed on days 4, 8, 12, and 16 (post-wound) was used to estimate total collagen, hexosamine, protein, DNA and uronic acid. Data were analyzed by Analysis of Variance (ANOVA) test. P<0.05 was considered statistically significant. Results: The extract increased cellular proliferation and collagen synthesis at the wound site, as evidenced by increase in DNA, total protein and total collagen content of granulation tissues. The extract-treated wounds were found to heal much faster as indicated by improved rates of epithelialization and wound contraction. The extract of H. rosa sinensis significantly (P<0.001) increased the wound-breaking strength in the incision wound model compared to controls. The extract-treated wounds were found to epithelialize faster, and the rate of wound contraction was significantly (P<0.001) increased as compared to control wounds. Wet and dry granulation tissue weights in a dead space wound model increased significantly (P<0.001). There was a significant increase in wound closure rate, tensile strength, dry granuloma weight, wet granuloma weight and decrease in epithelization period in H. rosa sinensis-treated group as compared to control and standard drug-treated groups. Conclusion: The ethanolic extract of H. rosa sinensis had greater wound-healing activity than the nitrofurazone ointment. PMID:23248396
Wong, J C H; Chung, C C; Yau, K K; Cheung, H Y S; Wong, D C T; Chan, O C Y; Li, M K W
2008-04-01
This study was designed to compare stapled vs. conventional hemorrhoidectomy for patients with acute thrombosed hemorrhoids. Forty-one patients with acute thrombosed hemorrhoids were randomized into: 1) stapled hemorrhoidectomy (PPH group; n = 21), and 2) open hemorrhoidectomy (open group; n = 20). Emergency surgery was performed with perioperative data and complications were recorded. Patients were followed up by independent assessors to evaluate pain, recurrence, continence function, and satisfaction at regular intervals. The median follow-up for the PPH group and open group were 59 and 56 weeks, respectively. There was no significant difference in terms of the hospital stay, complication rate, and continence function; however, the mean pain intensity in the first postoperative week was significantly less in the PPH group (4.1 vs. 5.7, P = 0.02). Patients in the PPH group recovered significantly faster in terms of the time to become analgesic-free (4 vs. 8.5 days, P < 0.01), time to become pain-free (9 vs. 20.5 days, P = 0.01), resumption of work (7 vs. 12.5 days, P = 0.01), and time for complete wound healing (2 vs. 4 weeks, P < 0.01). On long-term follow-up, significantly fewer patients in the PPH group complained of recurrent symptoms (0 vs. 5, P = 0.02). The overall symptom improvement and patients' satisfaction were significantly better in the PPH group (90 vs. 80 percent, P = 0.03 and +3 vs. +2, P < 0.01 respectively). Stapled hemorrhoidectomy is safe and effective for acute thrombosed hemorrhoids. Similar to elective stapled procedure, emergency stapled excision has greater short-term benefits compared with conventional excision: diminished pain, faster recovery, and earlier return to work. Long-term results and satisfaction were excellent.
NASA Astrophysics Data System (ADS)
Wang, Jinniu; Xu, Bo; Wu, Yan; Gao, Jing; Shi, Fusun
2016-10-01
Litters of reproductive organs have rarely been studied despite their role in allocating nutrients for offspring reproduction. This study determines the mechanism through which flower litters efficiently increase the available soil nutrient pool. Field experiments were conducted to collect plant litters and calculate biomass production in an alpine meadow of the eastern Tibetan Plateau. C, N, P, lignin, cellulose content, and their relevant ratios of litters were analyzed to identify their decomposition features. A pot experiment was performed to determine the effects of litter addition on the soil nutrition pool by comparing the treated and control samples. The litter-bag method was used to verify decomposition rates. The flower litters of phanerophyte plants were comparable with non-flower litters. Biomass partitioning of other herbaceous species accounted for 10-40 % of the aboveground biomass. Flower litter possessed significantly higher N and P levels but less C / N, N / P, lignin / N, and lignin and cellulose concentrations than leaf litter. The litter-bag experiment confirmed that the flower litters of Rhododendron przewalskii and Meconopsis integrifolia decompose approximately 3 times faster than mixed litters within 50 days. Pot experiment findings indicated that flower litter addition significantly increased the available nutrient pool and soil microbial productivity. The time of litter fall significantly influenced soil available N and P, and soil microbial biomass. Flower litters fed the soil nutrition pool and influenced nutrition cycling in alpine ecosystems more efficiently because of their non-ignorable production, faster decomposition rate, and higher nutrient contents compared with non-flower litters. The underlying mechanism can enrich nutrients, which return to the soil, and non-structural carbohydrates, which feed and enhance the transitions of soil microorganisms.
Stracke, Jan; Emrich, Thomas; Rueger, Petra; Schlothauer, Tilman; Kling, Lothar; Knaupp, Alexander; Hertenberger, Hubert; Wolfert, Andreas; Spick, Christian; Lau, Wilma; Drabner, Georg; Reiff, Ulrike; Koll, Hans; Papadimitriou, Apollon
2014-01-01
Preserving the chemical and structural integrity of therapeutic antibodies during manufacturing and storage is a major challenge during pharmaceutical development. Oxidation of Fc methionines Met252 and Met428 is frequently observed, which leads to reduced affinity to FcRn and faster plasma clearance if present at high levels. Because oxidation occurs in both positions simultaneously, their individual contribution to the concomitant changes in pharmacokinetic properties has not been clearly established. A novel pH-gradient FcRn affinity chromatography method was applied to isolate three antibody oxidation variants from an oxidized IgG1 preparation based on their FcRn binding properties. Physico-chemical characterization revealed that the three oxidation variants differed predominantly in the number of oxMet252 per IgG (0, 1, or 2), but not significantly in the content of oxMet428. Corresponding to the increase in oxMet252 content, stepwise reduction of FcRn affinity in vitro, as well as faster clearance and shorter terminal half-life, in huFcRn-transgenic mice were observed. A single Met252 oxidation per antibody had no significant effect on pharmacokinetics (PK) compared with unmodified IgG. Importantly, only molecules with both heavy chains oxidized at Met252 exhibited significantly faster clearance. In contrast, Met428 oxidation had no apparent negative effect on PK and even led to somewhat improved FcRn binding and slower clearance. This minor effect, however, seemed to be abrogated by the dominant effect of Met252 oxidation. The novel approach of functional chromatographic separation of IgG oxidation variants followed by physico-chemical and biological characterization has yielded the first experimentally-backed explanation for the unaltered PK properties of antibody preparations containing relatively high Met252 and Met428 oxidation levels. PMID:25517308
Schapschröer, M; Baker, J; Schorer, J
2016-08-01
In the context of perceptual-cognitive expertise it is important to know whether physiological loads influence perceptual-cognitive performance. This study examined whether a handball specific physical exercise load influenced participants' speed and accuracy in a flicker task. At rest and during a specific interval exercise of 86.5-90% HRmax, 35 participants (experts: n=8, advanced: n=13, novices, n=14) performed a handball specific flicker task with two types of patterns (structured and unstructured). For reaction time, results revealed moderate effect sizes for group, with experts reacting faster than advanced and advanced reacting faster than novices, and for structure, with structured videos being performed faster than unstructured ones. A significant interaction for structure×group was also found, with experts and advanced players faster for structured videos, and novices faster for unstructured videos. For accuracy, significant main effects were found for structure with structured videos solved more accurately. A significant interaction for structure×group was revealed, with experts and advanced more accurate for structured scenes and novices more accurate for unstructured scenes. A significant interaction was also found for condition×structure; at rest, unstructured and structured scenes were performed with the same accuracy while under physical exercise, structured scenes were solved more accurately. No other interactions were found. These results were somewhat surprising given previous work in this area, although the impact of a specific physical exercise on a specific perceptual-cognitive task may be different from those tested generally. Copyright © 2016 Elsevier B.V. All rights reserved.
Tyner, Bryan C; Fienup, Daniel M
2015-09-01
Graphing is socially significant for behavior analysts; however, graphing can be difficult to learn. Video modeling (VM) may be a useful instructional method but lacks evidence for effective teaching of computer skills. A between-groups design compared the effects of VM, text-based instruction, and no instruction on graphing performance. Participants who used VM constructed graphs significantly faster and with fewer errors than those who used text-based instruction or no instruction. Implications for instruction are discussed. © Society for the Experimental Analysis of Behavior.
Zhang, Wei; Tang, Xiaoxiang; He, Xianyou; Lai, Shuxian
2018-01-01
Substantial evidence suggests that beauty is associated with the survival and reproduction of organisms. Landscape architecture is composed of a series of natural elements that have significant evolutionary implications. The present study used one pilot material ratings and three experiments to examine the mechanisms of aesthetic appraisals of landscape architecture. The results confirmed that landscape architecture elicited a sense of beauty and captured visual attention more easily than other types of architecture during explicit aesthetic rating task (Experiment 1) and implicit aesthetic perception task (dot-probe paradigm, Experiment 2). Furthermore, the spatial cueing paradigm revealed that response latencies were significantly faster for landscape architecture than non-landscape architecture on valid trials, but there was no significant difference in this contrast on invalid trials at 150-ms stimulus onset asynchrony (SOA, Experiment 3a). At 500-ms SOA (Experiment 3b), participants responded significantly faster for landscape architecture on valid trials, but reacted significantly slower for landscape architecture on invalid trials. The findings indicated that the beauty of landscape architecture can be perceived implicitly, and only faster orienting of attention, but not delayed disengagement of attention was generated at early stages of the processing of landscape architecture. However, the attentional bias at later stages of attentional processes may be resulted from both faster orienting of attention and delayed disengagement of attention from landscape architecture photographs. PMID:29467696
Zhang, Wei; Tang, Xiaoxiang; He, Xianyou; Lai, Shuxian
2018-01-01
Substantial evidence suggests that beauty is associated with the survival and reproduction of organisms. Landscape architecture is composed of a series of natural elements that have significant evolutionary implications. The present study used one pilot material ratings and three experiments to examine the mechanisms of aesthetic appraisals of landscape architecture. The results confirmed that landscape architecture elicited a sense of beauty and captured visual attention more easily than other types of architecture during explicit aesthetic rating task (Experiment 1) and implicit aesthetic perception task (dot-probe paradigm, Experiment 2). Furthermore, the spatial cueing paradigm revealed that response latencies were significantly faster for landscape architecture than non-landscape architecture on valid trials, but there was no significant difference in this contrast on invalid trials at 150-ms stimulus onset asynchrony (SOA, Experiment 3a). At 500-ms SOA (Experiment 3b), participants responded significantly faster for landscape architecture on valid trials, but reacted significantly slower for landscape architecture on invalid trials. The findings indicated that the beauty of landscape architecture can be perceived implicitly, and only faster orienting of attention, but not delayed disengagement of attention was generated at early stages of the processing of landscape architecture. However, the attentional bias at later stages of attentional processes may be resulted from both faster orienting of attention and delayed disengagement of attention from landscape architecture photographs.
De Loof, Esther; Van Opstal, Filip; Verguts, Tom
2016-04-01
Theories on visual awareness claim that predicted stimuli reach awareness faster than unpredicted ones. In the current study, we disentangle whether prior information about the upcoming stimulus affects visual awareness of stimulus location (i.e., individuation) by modulating processing efficiency or threshold setting. Analogous research on stimulus identification revealed that prior information modulates threshold setting. However, as identification and individuation are two functionally and neurally distinct processes, the mechanisms underlying identification cannot simply be extrapolated directly to individuation. The goal of this study was therefore to investigate how individuation is influenced by prior information about the upcoming stimulus. To do so, a drift diffusion model was fitted to estimate the processing efficiency and threshold setting for predicted versus unpredicted stimuli in a cued individuation paradigm. Participants were asked to locate a picture, following a cue that was congruent, incongruent or neutral with respect to the picture's identity. Pictures were individuated faster in the congruent and neutral condition compared to the incongruent condition. In the diffusion model analysis, the processing efficiency was not significantly different across conditions. However, the threshold setting was significantly higher following an incongruent cue compared to both congruent and neutral cues. Our results indicate that predictive information about the upcoming stimulus influences visual awareness by shifting the threshold for individuation rather than by enhancing processing efficiency. Copyright © 2016 Elsevier Ltd. All rights reserved.
Looking and touching: what extant approaches reveal about the structure of early word knowledge.
Hendrickson, Kristi; Mitsven, Samantha; Poulin-Dubois, Diane; Zesiger, Pascal; Friend, Margaret
2015-09-01
The goal of the current study is to assess the temporal dynamics of vision and action to evaluate the underlying word representations that guide infants' responses. Sixteen-month-old infants participated in a two-alternative forced-choice word-picture matching task. We conducted a moment-by-moment analysis of looking and reaching behaviors as they occurred in tandem to assess the speed with which a prompted word was processed (visual reaction time) as a function of the type of haptic response: Target, Distractor, or No Touch. Visual reaction times (visual RTs) were significantly slower during No Touches compared to Distractor and Target Touches, which were statistically indistinguishable. The finding that visual RTs were significantly faster during Distractor Touches compared to No Touches suggests that incorrect and absent haptic responses appear to index distinct knowledge states: incorrect responses are associated with partial knowledge whereas absent responses appear to reflect a true failure to map lexical items to their target referents. Further, we found that those children who were faster at processing words were also those children who exhibited better haptic performance. This research provides a methodological clarification on knowledge measured by the visual and haptic modalities and new evidence for a continuum of word knowledge in the second year of life. © 2014 The Authors Developmental Science Published by John Wiley & Sons Ltd.
Porter, Jared M.; Nolan, Russell P.; Ostrowski, Erik J.; Wulf, Gabriele
2010-01-01
The primary purpose of this study was to investigate if focusing attention externally produced faster movement times compared to instructions that focused attention internally or a control set of instructions that did not explicitly focus attention when performing an agility task. A second purpose of the study was to measure participants’ focus of attention during practice by use of a questionnaire. Participants (N = 20) completed 15 trials of an agility “L” run following instructions designed to induce an external (EXT), internal (INT) attentional focus or a control (CON) set of instructions inducing no specific focus of attention. Analysis revealed when participants followed the EXT instructions they had significantly faster movement times compared to when they followed the INT and CON set of instructions; consistent with previous research the INT and CON movement times were not significantly different from each other. Qualitative data showed when participants were in the external condition they focused externally 67% of the time. When they were in the internal condition they focused internally 76% of the time, and when they were in the control condition they did not use an internal or external focus of attention 77% of the time. Qualitative data also revealed participants in the EXT, INT, and CON conditions switched their focus of attention at a frequency of 27, 35, and 51% respectively. PMID:21833271
NASA Astrophysics Data System (ADS)
Qayyum Khan, Abdul; Yuan, Shuai; Niu, Sheng; Liu, Fengjiang; Feng, Guang; Jiang, Mengci; Zeng, Heping
2018-01-01
Photocatalytic methalyne blue dye degradation was carried out with copper (Cu)-titanium dioxide (TiO2) nanocomposites under sunlight and visible light irradiation. The Cu-TiO2 nanocomposites were fabricated via femtosecond laser ablation of pressed targets in water. The current method provides a facile route for Cu-TiO2 nanocomposites preparation, which is free from impurities on the catalysts surface. The Cu-TiO2 nanocomposites (with Cu content of 5 wt%) have shown 3 folds faster dye degradation kinetics compared with TiO2 nanoparticles under sunlight irradiation. While under visible light irradiation, the same nanocomposites exhibited 2.6 folds faster kinetics compared with TiO2 nanoparticles. The faster light harvesting efficiency of the catalysts is attributed to more hydroxyl radical generation.
Solomon, Daniel; Shariff, Amir H; Silasi, Dan-Arin; Duffy, Andrew J; Bell, Robert L; Roberts, Kurt E
2012-10-01
This report describes the first prospective cohort study comparing transvaginal cholecystectomies (TVC) with single incision laparoscopic cholecystectomies (SILC) and four-port laparoscopic cholecystectomies (4PLC). Between May 2009 and August 2010, 14 patients underwent a TVC. These patients were compared with patients who underwent SILC (22 patients) or 4PLC (11 patients) in a concurrent, randomized, controlled trial. Demographic data, operative time, numerical pain scales, complications, and return to work were recorded. Mean age (TVC: 33.5 ± 3.0 year; SILC: 38.4 ± 3.3 year; 4PLC: 35.5 ± 4.1 year; p = 0.58) and mean BMI (TVC: 28.8 ± 1.5 kg/m(2); SILC: 31.8 ± 1 kg/m(2); 4PLC: 31.4 ± 2.2 kg/m(2); p = 0.35) were not statistically significant. However, mean operative time (TVC: 67 ± 3.9 min; SILC: 48.9 ± 2.6 min; 4PLC: 42.3 ± 3.9 min; p < 0.001) was significantly longer for TVC. Numerical pain scales showed significantly lower pain scores on POD 1 and 3 for TVC compared with SILC and 4PLC (TVC: 4.1 ± 0.5 and 2.9 ± 0.7; SILC: 6.1 ± 0.5 and 5.3 ± 0.5; 4PLC: 5.7 ± 0.4 and 4.7 ± 0.3; p = 0.02) with equilibration of pain scores by days 14 and 30. Return to work (TVC: 6.4 ± 1.5 days; SILC: 13.1 ± 1.3 days; 4PLC: 14.1 ± 1.4 days; p < 0.001) also was significantly faster for patients in the TVC group. One conversion in the TVC group to a 4PLC was necessary due to adhesions within the pelvis. One dislodged IUD was seen and immediately replaced in the TVC group. One hernia was observed in the SILC group. Transvaginal cholecystectomy is a safe and well-tolerated procedure with statistically significantly less pain at 1 and 3 days after surgery, with a faster return to work but longer operative times compared with single incision and four-port laparoscopic cholecystectomy.
Simkin, Dina; Hattori, Shoai; Ybarra, Natividad; Musial, Timothy F; Buss, Eric W; Richter, Hannah; Oh, M Matthew; Nicholson, Daniel A; Disterhoft, John F
2015-09-23
Aging-related impairments in hippocampus-dependent cognition have been attributed to maladaptive changes in the functional properties of pyramidal neurons within the hippocampal subregions. Much evidence has come from work on CA1 pyramidal neurons, with CA3 pyramidal neurons receiving comparatively less attention despite its age-related hyperactivation being postulated to interfere with spatial processing in the hippocampal circuit. Here, we use whole-cell current-clamp to demonstrate that aged rat (29-32 months) CA3 pyramidal neurons fire significantly more action potentials (APs) during theta-burst frequency stimulation and that this is associated with faster AP repolarization (i.e., narrower AP half-widths and enlarged fast afterhyperpolarization). Using a combination of patch-clamp physiology, pharmacology, Western blot analyses, immunohistochemistry, and array tomography, we demonstrate that these faster AP kinetics are mediated by enhanced function and expression of Kv4.2/Kv4.3 A-type K(+) channels, particularly within the perisomatic compartment, of CA3 pyramidal neurons. Thus, our study indicates that inhibition of these A-type K(+) channels can restore the intrinsic excitability properties of aged CA3 pyramidal neurons to a young-like state. Significance statement: Age-related learning deficits have been attributed, in part, to altered hippocampal pyramidal neuronal function with normal aging. Much evidence has come from work on CA1 neurons, with CA3 neurons receiving comparatively less attention despite its age-related hyperactivation being postulated to interfere with spatial processing. Hence, we conducted a series of experiments to identify the cellular mechanisms that underlie the hyperexcitability reported in the CA3 region. Contrary to CA1 neurons, we demonstrate that postburst afterhyperpolarization is not altered with aging and that aged CA3 pyramidal neurons are able to fire significantly more action potentials and that this is associated with faster action potential repolarization through enhanced expression of Kv4.2/Kv4.3 A-type K(+) channels, particularly within the cell bodies of CA3 pyramidal neurons. Copyright © 2015 the authors 0270-6474/15/3513206-13$15.00/0.
Simkin, Dina; Hattori, Shoai; Ybarra, Natividad; Musial, Timothy F.; Buss, Eric W.; Richter, Hannah; Oh, M. Matthew
2015-01-01
Aging-related impairments in hippocampus-dependent cognition have been attributed to maladaptive changes in the functional properties of pyramidal neurons within the hippocampal subregions. Much evidence has come from work on CA1 pyramidal neurons, with CA3 pyramidal neurons receiving comparatively less attention despite its age-related hyperactivation being postulated to interfere with spatial processing in the hippocampal circuit. Here, we use whole-cell current-clamp to demonstrate that aged rat (29–32 months) CA3 pyramidal neurons fire significantly more action potentials (APs) during theta-burst frequency stimulation and that this is associated with faster AP repolarization (i.e., narrower AP half-widths and enlarged fast afterhyperpolarization). Using a combination of patch-clamp physiology, pharmacology, Western blot analyses, immunohistochemistry, and array tomography, we demonstrate that these faster AP kinetics are mediated by enhanced function and expression of Kv4.2/Kv4.3 A-type K+ channels, particularly within the perisomatic compartment, of CA3 pyramidal neurons. Thus, our study indicates that inhibition of these A-type K+ channels can restore the intrinsic excitability properties of aged CA3 pyramidal neurons to a young-like state. SIGNIFICANCE STATEMENT Age-related learning deficits have been attributed, in part, to altered hippocampal pyramidal neuronal function with normal aging. Much evidence has come from work on CA1 neurons, with CA3 neurons receiving comparatively less attention despite its age-related hyperactivation being postulated to interfere with spatial processing. Hence, we conducted a series of experiments to identify the cellular mechanisms that underlie the hyperexcitability reported in the CA3 region. Contrary to CA1 neurons, we demonstrate that postburst afterhyperpolarization is not altered with aging and that aged CA3 pyramidal neurons are able to fire significantly more action potentials and that this is associated with faster action potential repolarization through enhanced expression of Kv4.2/Kv4.3 A-type K+ channels, particularly within the cell bodies of CA3 pyramidal neurons. PMID:26400949
Stimulus fear relevance and the speed, magnitude, and robustness of vicariously learned fear.
Dunne, Güler; Reynolds, Gemma; Askew, Chris
2017-08-01
Superior learning for fear-relevant stimuli is typically indicated in the laboratory by faster acquisition of fear responses, greater learned fear, and enhanced resistance to extinction. Three experiments investigated the speed, magnitude, and robustness of UK children's (6-10 years; N = 290; 122 boys, 168 girls) vicariously learned fear responses for three types of stimuli. In two experiments, children were presented with pictures of novel animals (Australian marsupials) and flowers (fear-irrelevant stimuli) alone (control) or together with faces expressing fear or happiness. To determine learning speed the number of stimulus-face pairings seen by children was varied (1, 10, or 30 trials). Robustness of learning was examined via repeated extinction procedures over 3 weeks. A third experiment compared the magnitude and robustness of vicarious fear learning for snakes and marsupials. Significant increases in fear responses were found for snakes, marsupials and flowers. There was no indication that vicarious learning for marsupials was faster than for flowers. Moreover, vicariously learned fear was neither greater nor more robust for snakes compared to marsupials, or for marsupials compared to flowers. These findings suggest that for this age group stimulus fear relevance may have little influence on vicarious fear learning. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kemeny, Steven Frank; Clyne, Alisa Morss
2011-04-01
Fiber alignment plays a critical role in the structure and function of cells and tissues. While fiber alignment quantification is important to experimental analysis and several different methods for quantifying fiber alignment exist, many studies focus on qualitative rather than quantitative analysis perhaps due to the complexity of current fiber alignment methods. Speed and sensitivity were compared in edge detection and fast Fourier transform (FFT) for measuring actin fiber alignment in cells exposed to shear stress. While edge detection using matrix multiplication was consistently more sensitive than FFT, image processing time was significantly longer. However, when MATLAB functions were used to implement edge detection, MATLAB's efficient element-by-element calculations and fast filtering techniques reduced computation cost 100 times compared to the matrix multiplication edge detection method. The new computation time was comparable to the FFT method, and MATLAB edge detection produced well-distributed fiber angle distributions that statistically distinguished aligned and unaligned fibers in half as many sample images. When the FFT sensitivity was improved by dividing images into smaller subsections, processing time grew larger than the time required for MATLAB edge detection. Implementation of edge detection in MATLAB is simpler, faster, and more sensitive than FFT for fiber alignment quantification.
Pellegrini, L; Belcaro, G; Dugall, M; Hu, S; Gizzi, G; Corsi, M; Hosoi, M; Luzzi, R; Feragalli, B; Cotellese, R
2015-10-22
Mild, temporary hepatic failure (MTHF) after chemotherapy is a common clinical problem; in case of repeated episodes MTHF may cause chronic impairment. This registry has evaluated post- chemotherapy (PC)-MTHF in subjects using Liverubin (standardized Silymarin) for 8 weeks (3 capsules/day). PC-MTHF was evaluated in a registry study. Hepatitis markers were negative at inclusion and at end-registry. In the final registry there were results concerning 18 Liverubin-supplemented patients and 19 controls completing the 8-week period. Signs/symptoms. The distribution of the most common symptoms and signs with ultrasound scans were comparable. Symptoms were mostly minimal or subclinical. Most symptoms observed at inclusion were completely disappeared or greatly attenuated after 8 weeks. The improvement produced by Liverubin induced a better and faster disappearance of symptoms. The results of the blood tests (at inclusion and at 8 weeks showed the increase in albumin, significantly (P<0.05) faster with the final values higher in the supplement group. Total bilirubin was reduced with the supplement better than in controls (P<0.05). Direct bilirubin values improved more in the supplement (P<0.05) group. The decrease in SGPT and AST-ASAT was more evident with the supplement (P<0.05). Improvement in controls was more limited. Alkaline phosphatase was significantly lower (than in controls) with Liverubin at 8 weeks (p<0.05). Gamma GT also decreased more and faster with the supplement. The ESR (erythrocytes sedimentation rate) was decreased in both groups, more in the Liverubin group (P<0.05). There was a more limited decrease in controls with persisting higher values at 8 weeks. The white cell count was also better at 3 months (with a larger decrease with the supplement; P<0.05). Oxidative stress. Plasma free radicals (PFR) were elevated in both groups at inclusion. A more significant decrease in the supplement group was observed at 8 weeks. Persisting elevation in values was seen in controls (P<0.05). Platelets values improved better with Liverubin (P<0.05). Safety and tolerability were optimal (no side effect was registered). In conclusion, results from this pilot registry indicate a significant activity of Liverubin associated with a very good safety profile, in patients with post-chemotherapy hepatic failure. The recovery of hepatic function is faster and more effective with Liverubin in comparison with the best "standard" management.
Vide, João; Freitas, Tânia Pinto; Ramos, Acácio; Cruz, Henrique; Sousa, João Paulo
2017-08-01
This randomized controlled trial was conducted to compare patient-specific instrumentation (PSI) to standard instrumentation regarding efficacy to achieve a good coronal alignment and differences in surgical time, blood loss and length of stay. Ninety-five of 100 randomized patients eligible for total knee arthroplasty were analysed. PSI with magnetic resonance and long-leg radiograph was performed in 47 patients, while 48 patients received standard instrumentation. Primary outcome measure was coronal alignment, evaluated with long-leg radiograph. Deviation >3° varus/valgus was considered an outlier. Surgical time was compared from skin to skin. Length of stay was a post hoc analysis. Blood loss was evaluated comparing the number of blood units spent, fall in haemoglobin and haematocrit levels. Standard instrumentation had a higher number of outliers in the coronal alignment with a relative risk of 3.015, compared to PSI. Surgical time was reduced by 18 min (24.8 %) with the PSI, as well as length of stay, with a half-day reduction. Number of blood units spent was significantly less in the PSI group. Relative risk of transfusion was 7.09 for patients in the standard instrumentation group. Difference in Hg and Htc levels were not significant. No patient had to abandon PSI. Minor changes to preoperative plan occurred in 14.9 % of the patient: cut review in 4.3 % and insert change in 10.6 %. Patient-specific instrumentation (PSI) is able to provide important advantages over standard instrumentation in total knee arthroplasty: it lowers the risk of outliers and transfusion, is a faster procedure and enables a shorter length of stay with a low rate of intraoperative adjustments. I.
Yarmus, Lonny B; Semaan, Roy W; Arias, Sixto A; Feller-Kopman, David; Ortiz, Ricardo; Bösmüller, Hans; Illei, Peter B; Frimpong, Bernice O; Oakjones-Burgess, Karen; Lee, Hans J
2016-08-01
Transbronchial forceps biopsy (FBx) has been the preferred method for obtaining bronchoscopic lung biopsy specimens. Cryoprobe biopsy (CBx) has been shown to obtain larger and higher quality samples, but is limited by its inability to retrieve the sample through the working channel of the bronchoscope, requiring the bronchoscope to leave the airway for sample retrieval. We evaluated a novel device using a sheath cryobiopsy (SCBx). This method allows for specimen retrieval through the working channel of the bronchoscope, with the scope remaining inside the airway. This prospective, randomized controlled, single-blinded porcine study compared a 1.1-mm SCBx probe, a 1.9-mm CBx probe, and 2.0-mm FBx forceps. Assessment of histologic accessibility, sample quantity and quality, number of attempts to acquire and retrieve samples, cryoprobe activation time, fluoroscopy activation time, technical feasibility, and complications were compared. Samples adequate for standard pathologic processing were retrieved with 82.1% of the SCBx specimens, 82.9%% of the CBx specimens, and 30% of the FBx specimens. The histologic accessibility of both SCBx (P = .0002) and CBx (P = .0003) was superior to FBx. Procedure time for FBx was faster than for both SCBx and CBx, but SCBx was significantly faster than CBx (P < .0001). Fluoroscopy time was lower for both SCBx and CBx compared with FBx. There were no significant bleeding events. SCBx is a feasible technique providing a higher quality lung biopsy specimen compared with FBx and can successfully be retrieved through the working channel. Human studies are needed to further assess this technique with additional safety data. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Kemppainen, B W; Riley, R T; Biles-Thurlow, S
1987-05-01
The purpose of this research was to determine the rate of cutaneous penetration and metabolism of [3H]diacetoxyscirpenol (DAS) and [3H]verrucarin A (VCA) and compare these values to previously determined values for [3H]T-2 toxin (T-2), to compare the cutaneous penetration and metabolism of DAS in human and guinea-pig skin, and to compare the effects of dose and of two vehicles, methanol and dimethylsulphoxide (DMSO), on penetration rates. DAS or VCA was applied to the epidermal surface of excised skin, and the receptor fluid bathing the dermal surface was sampled periodically for 48 hr. Whether the applied dose (581 ng/cm2) was dissolved in methanol or DMSO, the rate of penetration through human skin was lower for VCA than for DAS or T-2, the rates for the two latter compounds being similar at this dose. Metabolism of DAS occurred during penetration through excised human skin and did not occur in the receptor fluid as a result of enzymes leaching out of the skin. VCA appeared to be metabolized by human skin, but this conclusion is tentative because of the relative instability of this compound. DAS penetrated significantly (P less than 0.05) faster through excised guinea-pig skin than through human skin. Metabolism of DAS was greater in human skin than in guinea-pig skin. When compared with methanol, DMSO increased the penetration of DAS and VCA by factors of between 7 and 52. At the low dose (79 ng/cm2) DAS penetrated human and guinea-pig skin significantly (P less than 0.05) faster than T-2 using either vehicle.
Barikroo, Ali; Berretin-Felix, Giedré; Carnaby, Giselle; Crary, Michael
2017-03-01
This study compared the effect of transcutaneous electrical stimulation (TES) amplitude on timing of lingual-palatal and pharyngeal peak pressures during swallowing in healthy younger and older adults. Transcutaneous electrical stimulation amplitude is one parameter that may have different impacts on the neuromotor system and swallowing physiology. One aspect of swallowing physiology influenced by age is the timing of swallowing events. However, the effect of varying TES amplitudes on timing of swallowing physiology is poorly understood, especially in older adults. Thirty-four adults (20 younger and 14 older) swallowed 10 ml of nectar-thick liquid under three TES conditions: no stimulation, low-amplitude stimulation and high-amplitude stimulation. TES was delivered by surface electrodes on the anterior neck. Timing of pressure peaks for lingual-palatal contacts and pharyngeal pressures were measured under each condition. A significant age × stimulation amplitude interaction was identified for the base of tongue (BOT) [F(2,62) = 5.087, p < 0.009] and the hypopharynx (HYPO) [F(2,62) = 3.277, p < 0.044]. At the BOT, low-amplitude TES resulted in slower swallows in the younger adults compared with no TES. In older adults, low-amplitude TES resulted in faster swallows compared with high-amplitude TES. At the HYPO, no significant differences were identified in pressure timing across the three TES amplitudes in both age groups. In each case, low-amplitude TES resulted in faster swallows in older adults compared with younger adults. Transcutaneous electrical stimulation influences pharyngeal pressure timing differently in young and old people, which questions the appropriateness of using a 'one-size-fits-all' TES amplitude for rehabilitating people with dysphagia. © 2015 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.
Sugammadex: A Review of Neuromuscular Blockade Reversal.
Keating, Gillian M
2016-07-01
Sugammadex (Bridion(®)) is a modified γ-cyclodextrin that reverses the effect of the steroidal nondepolarizing neuromuscular blocking agents rocuronium and vecuronium. Intravenous sugammadex resulted in rapid, predictable recovery from moderate and deep neuromuscular blockade in patients undergoing surgery who received rocuronium or vecuronium. Recovery from moderate neuromuscular blockade was significantly faster with sugammadex 2 mg/kg than with neostigmine, and recovery from deep neuromuscular blockade was significantly faster with sugammadex 4 mg/kg than with neostigmine or spontaneous recovery. In addition, recovery from neuromuscular blockade was significantly faster when sugammadex 16 mg/kg was administered 3 min after rocuronium than when patients spontaneously recovered from succinylcholine. Sugammadex also demonstrated efficacy in various special patient populations, including patients with pulmonary disease, cardiac disease, hepatic dysfunction or myasthenia gravis and morbidly obese patients. Intravenous sugammadex was generally well tolerated. In conclusion, sugammadex is an important option for the rapid reversal of rocuronium- or vecuronium-induced neuromuscular blockade.
Skeletal Growth Dysregulation in Australian Male Infants and Toddlers With Autism Spectrum Disorder.
Green, Cherie C; Dissanayake, Cheryl; Loesch, Danuta Z; Bui, Minh; Barbaro, Josephine
2018-06-01
Recent findings suggest that children with Autism Spectrum Disorder (ASD) are larger in size for head circumference (HC), height, and weight compared to typically developing (TD) children; however, little is known about their rate of growth, especially in height and weight. The current study aimed to: (a) confirm and extend upon previous findings of early generalized overgrowth in ASD; and (b) determine if there were any differences in the rate of growth between infants and toddlers with ASD compared to their TD peers. Measurements of HC, height, and weight were available for 135 boys with ASD and 74 TD boys, from birth through 3 years of age. Size and growth rate in HC, height, and weight were analyzed using a linear mixed-effects model. Infants with ASD were significantly smaller in size at birth for HC, body length, and weight compared to TD infants (all P < 0.05); however, they grew at a significantly faster rate in HC and height in comparison to the TD children (P < 0.001); there was no significant difference between the groups in growth rate for weight (P > 0.05). The results confirmed that male infants and toddlers with ASD exhibit skeletal growth dysregulation early in life. Autism Res 2018, 11: 846-856. © 2018 International Society for Autism Research, Wiley Periodicals, Inc. Recent findings suggest that infants with Autism Spectrum Disorder (ASD) are smaller in size at birth compared to typically developing infants but grow larger than their peers during the first year. Little is known about their rate of growth, especially for height and weight. Our findings confirmed that infants with ASD are smaller in size at birth for head circumference (HC), height, and weight, but grow at a faster rate in HC and height than their peers from birth to 3 years. © 2018 International Society for Autism Research, Wiley Periodicals, Inc.
Lai, Hou-Chuan; Chan, Shun-Ming; Lu, Chueng-He; Wong, Chih-Shung; Cherng, Chen-Hwan; Wu, Zhi-Fu
2017-02-01
Reducing anesthesia-controlled time (ACT) may improve operation room (OR) efficiency result from different anesthetic techniques. However, the information about the difference in ACT between desflurane (DES) anesthesia and propofol-based total intravenous anesthesia (TIVA) techniques for open major upper abdominal surgery under general anesthesia (GA) is not available in the literature.This retrospective study uses our hospital database to analyze the ACT of open major upper abdominal surgery without liver resection after either desflurane/fentanyl-based anesthesia or TIVA via target-controlled infusion with fentanyl/propofol from January 2010 to December 2011. The various time intervals including waiting for anesthesia time, anesthesia time, surgical time, extubation time, exit from OR after extubation, total OR time, and postanesthetic care unit (PACU) stay time and percentage of prolonged extubation (≥15 minutes) were compared between these 2 anesthetic techniques.We included data from 343 patients, with 159 patients receiving TIVA and 184 patients receiving DES. The only significant difference is extubation time, TIVA was faster than the DES group (8.5 ± 3.8 vs 9.4 ± 3.7 minutes; P = 0.04). The factors contributed to prolonged extubation were age, gender, body mass index, DES anesthesia, and anesthesia time.In our hospital, propofol-based TIVA by target-controlled infusion provides faster emergence compared with DES anesthesia; however, it did not improve OR efficiency in open major abdominal surgery. Older, male gender, higher body mass index, DES anesthesia, and lengthy anesthesia time were factors that contribute to extubation time.
Detection and diagnosis of colitis on computed tomography using deep convolutional neural networks.
Liu, Jiamin; Wang, David; Lu, Le; Wei, Zhuoshi; Kim, Lauren; Turkbey, Evrim B; Sahiner, Berkman; Petrick, Nicholas A; Summers, Ronald M
2017-09-01
Colitis refers to inflammation of the inner lining of the colon that is frequently associated with infection and allergic reactions. In this paper, we propose deep convolutional neural networks methods for lesion-level colitis detection and a support vector machine (SVM) classifier for patient-level colitis diagnosis on routine abdominal CT scans. The recently developed Faster Region-based Convolutional Neural Network (Faster RCNN) is utilized for lesion-level colitis detection. For each 2D slice, rectangular region proposals are generated by region proposal networks (RPN). Then, each region proposal is jointly classified and refined by a softmax classifier and bounding-box regressor. Two convolutional neural networks, eight layers of ZF net and 16 layers of VGG net are compared for colitis detection. Finally, for each patient, the detections on all 2D slices are collected and a SVM classifier is applied to develop a patient-level diagnosis. We trained and evaluated our method with 80 colitis patients and 80 normal cases using 4 × 4-fold cross validation. For lesion-level colitis detection, with ZF net, the mean of average precisions (mAP) were 48.7% and 50.9% for RCNN and Faster RCNN, respectively. The detection system achieved sensitivities of 51.4% and 54.0% at two false positives per patient for RCNN and Faster RCNN, respectively. With VGG net, Faster RCNN increased the mAP to 56.9% and increased the sensitivity to 58.4% at two false positive per patient. For patient-level colitis diagnosis, with ZF net, the average areas under the ROC curve (AUC) were 0.978 ± 0.009 and 0.984 ± 0.008 for RCNN and Faster RCNN method, respectively. The difference was not statistically significant with P = 0.18. At the optimal operating point, the RCNN method correctly identified 90.4% (72.3/80) of the colitis patients and 94.0% (75.2/80) of normal cases. The sensitivity improved to 91.6% (73.3/80) and the specificity improved to 95.0% (76.0/80) for the Faster RCNN method. With VGG net, Faster RCNN increased the AUC to 0.986 ± 0.007 and increased the diagnosis sensitivity to 93.7% (75.0/80) and specificity was unchanged at 95.0% (76.0/80). Colitis detection and diagnosis by deep convolutional neural networks is accurate and promising for future clinical application. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.
Saunders, Stuart M; Ellis, Scott J; Demetracopoulos, Constantine A; Marinescu, Anca; Burkett, Jayme; Deland, Jonathan T
2018-01-01
The forefoot abduction component of the flexible adult-acquired flatfoot can be addressed with lengthening of the anterior process of the calcaneus. We hypothesized that the step-cut lengthening calcaneal osteotomy (SLCO) would decrease the incidence of nonunion, lead to improvement in clinical outcome scores, and have a faster time to healing compared with the traditional Evans osteotomy. We retrospectively reviewed 111 patients (143 total feet: 65 Evans, 78 SLCO) undergoing stage IIB reconstruction followed clinically for at least 2 years. Preoperative and postoperative radiographs were analyzed for the amount of deformity correction. Computed tomography (CT) was used to analyze osteotomy healing. The Foot and Ankle Outcome Scores (FAOS) and lateral pain surveys were used to assess clinical outcomes. Mann-Whitney U tests were used to assess nonnormally distributed data while χ 2 and Fisher exact tests were used to analyze categorical variables (α = 0.05 significant). The Evans group used a larger graft size ( P < .001) and returned more often for hardware removal ( P = .038) than the SLCO group. SLCO union occurred at a mean of 8.77 weeks ( P < .001), which was significantly lower compared with the Evans group ( P = .02). The SLCO group also had fewer nonunions ( P = .016). FAOS scores improved equivalently between the 2 groups. Lateral column pain, ability to exercise, and ambulation distance were similar between groups. Following SLCO, patients had faster healing times and fewer nonunions, similar outcomes scores, and equivalent correction of deformity. SLCO is a viable technique for lateral column lengthening. Level III, retrospective cohort study.
Werner, Joseph G; Castellon-Larios, Karina; Thongrong, Cattleya; Knudsen, Bodo E; Lowery, Deborah S; Antor, Maria A; Bergese, Sergio Daniel
2015-01-01
We compared the effect of desflurane and sevoflurane on anesthesia recovery time in patients undergoing urological cystoscopic surgery. The Short Orientation-Memory-Concentration Test (SOMCT) measured and compared cognitive impairment between groups and coughing was assessed throughout the anesthetic. This investigation included 75 ambulatory patients. Patients were randomized to receive either desflurane or sevoflurane. Inhalational anesthetics were discontinued after removal of the cystoscope and once repositioning of the patient was final. Coughing assessment and awakening time from anesthesia were assessed by a blinded observer. Statistical analysis was performed by using t-test for parametric variables and Mann-Whitney U test for non-parametric variables. The primary endpoint, mean time to eye-opening, was 5.0 ± 2.5 min for desflurane and 7.9 ± 4.1 min for sevoflurane (p < 0.001). There were no significant differences in time to SOMCT recovery (p = 0.109), overall time spent in the post-anesthesia care unit (PACU) (p = 0.924) or time to discharge (p = 0.363). Median time until readiness for discharge was 9 min in the desflurane group, while the sevoflurane group had a median time of 20 min (p = 0.020). The overall incidence of coughing during the perioperative period was significantly higher in the desflurane (p = 0.030). We re-confirmed that patients receiving desflurane had a faster emergence and met the criteria to be discharged from the PACU earlier. No difference was found in time to return to baseline cognition between desflurane and sevoflurane.
Van Bruwaene, Siska; Schijven, Marlies P; Napolitano, Daniel; De Win, Gunter; Miserez, Marc
2015-01-01
As conventional laparoscopic procedural training requires live animals or cadaver organs, virtual simulation seems an attractive alternative. Therefore, we compared the transfer of training for the laparoscopic cholecystectomy from porcine cadaver organs vs virtual simulation to surgery in a live animal model in a prospective randomized trial. After completing an intensive training in basic laparoscopic skills, 3 groups of 10 participants proceeded with no additional training (control group), 5 hours of cholecystectomy training on cadaver organs (= organ training) or proficiency-based cholecystectomy training on the LapMentor (= virtual-reality training). Participants were evaluated on time and quality during a laparoscopic cholecystectomy on a live anaesthetized pig at baseline, 1 week (= post) and 4 months (= retention) after training. All research was performed in the Center for Surgical Technologies, Leuven, Belgium. In total, 30 volunteering medical students without prior experience in laparoscopy or minimally invasive surgery from the University of Leuven (Belgium). The organ training group performed the procedure significantly faster than the virtual trainer and borderline significantly faster than control group at posttesting. Only 1 of 3 expert raters suggested significantly better quality of performance of the organ training group compared with both the other groups at posttesting (p < 0.01). There were no significant differences between groups at retention testing. The virtual trainer group did not outperform the control group at any time. For trainees who are proficient in basic laparoscopic skills, the long-term advantage of additional procedural training, especially on a virtual but also on the conventional organ training model, remains to be proven. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Gomes, S; Civetta, A
2014-09-01
Hybrid male sterility is a common outcome of crosses between different species. Gene expression studies have found that a number of spermatogenesis genes are differentially expressed in sterile hybrid males, compared with parental species. Late-stage sperm development genes are particularly likely to be misexpressed, with fewer early-stage genes affected. Thus, a link has been posited between misexpression and sterility. A more recent alternative explanation for hybrid gene misexpression has been that it is independent of sterility and driven by divergent evolution of male-specific regulatory elements between species (faster male hypothesis). The faster male hypothesis predicts that misregulation of spermatogenesis genes should be independent of sterility and approximately the same in both hybrids, whereas sterility should only affect gene expression in sterile hybrids. To test the faster male hypothesis vs. the effect of sterility on gene misexpression, we analyse spermatogenesis gene expression in different species pairs of the Drosophila phylogeny, where hybrid male sterility occurs in only one direction of the interspecies cross (i.e. unidirectional sterility). We find significant differences among genes in misexpression with effects that are lineage-specific and caused by sterility or fast male regulatory divergence. © 2014 The Authors. Journal of Evolutionary Biology © 2014 European Society For Evolutionary Biology.
Leney, Jocelyn L; Drouillard, Ken G; Haffner, G Douglas
2006-11-01
Polychlorinated biphenyl (PCB) elimination rates were used to determine whether green frogs (Rana clamitans) and leopard frogs (Rana pipiens) at three life stages (tadpole, metamorph, and adult) were capable of metabolic biotransformation of PCBs. Polychlorinated biphenyls were grouped according to their structural properties to determine whether congeners with specific structures were eliminated more rapidly than others, which would suggest the occurrence of metabolic biotransformation. For both species and at all life stages studied, PCBs with adjacent unsubstituted meta-para sites (group-2 PCBs) were eliminated significantly faster than PCBs with adjacent unsubstituted ortho-meta sites (group-3 PCBs). Because these groups of PCBs span similar hydrophobicity ranges, it was concluded that green and leopard frogs can selectively metabolize group-2 PCBs. Metabolic activity was more pronounced in the metamorph stage than in any other life stage. In green frog metamorphs, the average elimination rate of the group-2 PCBs was 4.9-fold greater than that of the group-3 PCBs. By contrast, in green frog tadpoles, group-2 PCBs were eliminated 1.9-fold faster than group-3 PCBs, and in green frog adults, group-2 PCBs were eliminated 1.5-fold faster than group-3 PDBs.
Gluskin, A H; Brown, D C; Buchanan, L S
2001-09-01
The aim of this study was to compare the effects of preparation with conventional stainless steel Flexofiles and Gates Glidden burs versus nickel-titanium GT rotary files in the shaping of mesial root canals of extracted mandibular molars. A total of 54 canals from 27 mesial roots of mandibular molar teeth were prepared using one of two methods by novice dental students. One canal in each root was prepared by a crown-down approach. utilizing stainless steel Flexofiles and Gates Glidden burs. The other canal was prepared using nickel-titanium GT rotary files in a crown-down fashion as recommended by the manufacturer. Preoperative CT scans of each root were recorded and 50 canal specimens were available for postoperative comparisons. Following canal shaping, postoperative scans were superimposed on the original images. Changes in canal area, canal transportation and thickness of remaining root structure at strategic levels of the root were analyzed. The time taken for each method was also noted. At the coronal and mid-root coronal one-third sections, the rotary GT files produced a significantly smaller postoperative canal area (P < 0.05). In the mid-root sections there was significantly less transportation of the root canal toward the furcation, and less thinning of the root structure with GT files compared to the stainless steel files (P < 0.05). Overall, there was greater conservation of structure coronally and more adequate shape in the mid-root level. The GT rotary technique was significantly faster than the stainless steel hand-held file technique (P < 0.0001). Two GT instruments fractured during the study. Under the conditions of this study, novice dental students were able to prepare curved root canals with Ni-Ti GT rotary files with less transportation and greater conservation of tooth structure, compared to canals prepared with hand instruments. The rotary technique was significantly faster.
The metabolic and performance effects of caffeine compared to coffee during endurance exercise.
Hodgson, Adrian B; Randell, Rebecca K; Jeukendrup, Asker E
2013-01-01
There is consistent evidence supporting the ergogenic effects of caffeine for endurance based exercise. However, whether caffeine ingested through coffee has the same effects is still subject to debate. The primary aim of the study was to investigate the performance enhancing effects of caffeine and coffee using a time trial performance test, while also investigating the metabolic effects of caffeine and coffee. In a single-blind, crossover, randomised counter-balanced study design, eight trained male cyclists/triathletes (Mean ± SD: Age 41 ± 7 y, Height 1.80 ± 0.04 m, Weight 78.9 ± 4.1 kg, VO2 max 58 ± 3 ml • kg(-1) • min(-1)) completed 30 min of steady-state (SS) cycling at approximately 55% VO2max followed by a 45 min energy based target time trial (TT). One hour prior to exercise each athlete consumed drinks consisting of caffeine (5 mg CAF/kg BW), instant coffee (5 mg CAF/kg BW), instant decaffeinated coffee or placebo. The set workloads produced similar relative exercise intensities during the SS for all drinks, with no observed difference in carbohydrate or fat oxidation. Performance times during the TT were significantly faster (~5.0%) for both caffeine and coffee when compared to placebo and decaf (38.35 ± 1.53, 38.27 ± 1.80, 40.23 ± 1.98, 40.31 ± 1.22 min respectively, p<0.05). The significantly faster performance times were similar for both caffeine and coffee. Average power for caffeine and coffee during the TT was significantly greater when compared to placebo and decaf (294 ± 21 W, 291 ± 22 W, 277 ± 14 W, 276 ± 23 W respectively, p<0.05). No significant differences were observed between placebo and decaf during the TT. The present study illustrates that both caffeine (5 mg/kg/BW) and coffee (5 mg/kg/BW) consumed 1 h prior to exercise can improve endurance exercise performance.
The Metabolic and Performance Effects of Caffeine Compared to Coffee during Endurance Exercise
Hodgson, Adrian B.; Randell, Rebecca K.; Jeukendrup, Asker E.
2013-01-01
There is consistent evidence supporting the ergogenic effects of caffeine for endurance based exercise. However, whether caffeine ingested through coffee has the same effects is still subject to debate. The primary aim of the study was to investigate the performance enhancing effects of caffeine and coffee using a time trial performance test, while also investigating the metabolic effects of caffeine and coffee. In a single-blind, crossover, randomised counter-balanced study design, eight trained male cyclists/triathletes (Mean±SD: Age 41±7y, Height 1.80±0.04 m, Weight 78.9±4.1 kg, VO2 max 58±3 ml•kg−1•min−1) completed 30 min of steady-state (SS) cycling at approximately 55% VO2max followed by a 45 min energy based target time trial (TT). One hour prior to exercise each athlete consumed drinks consisting of caffeine (5 mg CAF/kg BW), instant coffee (5 mg CAF/kg BW), instant decaffeinated coffee or placebo. The set workloads produced similar relative exercise intensities during the SS for all drinks, with no observed difference in carbohydrate or fat oxidation. Performance times during the TT were significantly faster (∼5.0%) for both caffeine and coffee when compared to placebo and decaf (38.35±1.53, 38.27±1.80, 40.23±1.98, 40.31±1.22 min respectively, p<0.05). The significantly faster performance times were similar for both caffeine and coffee. Average power for caffeine and coffee during the TT was significantly greater when compared to placebo and decaf (294±21 W, 291±22 W, 277±14 W, 276±23 W respectively, p<0.05). No significant differences were observed between placebo and decaf during the TT. The present study illustrates that both caffeine (5 mg/kg/BW) and coffee (5 mg/kg/BW) consumed 1 h prior to exercise can improve endurance exercise performance. PMID:23573201
Differential emotional processing in concrete and abstract words.
Yao, Bo; Keitel, Anne; Bruce, Gillian; Scott, Graham G; O'Donnell, Patrick J; Sereno, Sara C
2018-02-12
Emotion (positive and negative) words are typically recognized faster than neutral words. Recent research suggests that emotional valence, while often treated as a unitary semantic property, may be differentially represented in concrete and abstract words. Studies that have explicitly examined the interaction of emotion and concreteness, however, have demonstrated inconsistent patterns of results. Moreover, these findings may be limited as certain key lexical variables (e.g., familiarity, age of acquisition) were not taken into account. We investigated the emotion-concreteness interaction in a large-scale, highly controlled lexical decision experiment. A 3 (Emotion: negative, neutral, positive) × 2 (Concreteness: abstract, concrete) design was used, with 45 items per condition and 127 participants. We found a significant interaction between emotion and concreteness. Although positive and negative valenced words were recognized faster than neutral words, this emotion advantage was significantly larger in concrete than in abstract words. We explored potential contributions of participant alexithymia level and item imageability to this interactive pattern. We found that only word imageability significantly modulated the emotion-concreteness interaction. While both concrete and abstract emotion words are advantageously processed relative to comparable neutral words, the mechanisms of this facilitation are paradoxically more dependent on imageability in abstract words. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Sonmez, Hayriye; Sari, Saziye
2016-01-01
Introduction. The aim of this study was to compare MTA with another base material, IRM, which is generally used on pulpal floor after root canal treatment, regarding their effect on the success of root canal treatment of primary teeth with furcation lesions. Materials and Methods. Fifty primary teeth with furcation lesions were divided into 2 groups. Following root canal treatment, the pulpal floor was coated with MTA in the experimental group and with IRM in the control group. Teeth were followed up considering clinical (pain, pathological mobility, tenderness to percussion and palpation, and any soft tissue pathology and sinus tract) and radiographical (pathological root resorption, reduced size or healing of existing lesion, and absence of new lesions at the interradicular or periapical area) criteria for 18 months. For the statistical analysis, Fisher's exact test and Pearson's chi-square tests were used and a p value of <0.05 was considered to be statistically significant. Results. Although there were no statistically significant differences between two groups in terms of treatment success, lesions healed significantly faster in the MTA group. Conclusion. In primary teeth with furcation lesions, usage of MTA on the pulpal floor following root canal treatment can be a better alternative since it induced faster healing. PMID:27957486
Arikan, Volkan; Sonmez, Hayriye; Sari, Saziye
2016-01-01
Introduction. The aim of this study was to compare MTA with another base material, IRM, which is generally used on pulpal floor after root canal treatment, regarding their effect on the success of root canal treatment of primary teeth with furcation lesions. Materials and Methods. Fifty primary teeth with furcation lesions were divided into 2 groups. Following root canal treatment, the pulpal floor was coated with MTA in the experimental group and with IRM in the control group. Teeth were followed up considering clinical (pain, pathological mobility, tenderness to percussion and palpation, and any soft tissue pathology and sinus tract) and radiographical (pathological root resorption, reduced size or healing of existing lesion, and absence of new lesions at the interradicular or periapical area) criteria for 18 months. For the statistical analysis, Fisher's exact test and Pearson's chi-square tests were used and a p value of <0.05 was considered to be statistically significant. Results. Although there were no statistically significant differences between two groups in terms of treatment success, lesions healed significantly faster in the MTA group. Conclusion. In primary teeth with furcation lesions, usage of MTA on the pulpal floor following root canal treatment can be a better alternative since it induced faster healing.
Faster Smith-Waterman database searches with inter-sequence SIMD parallelisation
2011-01-01
Background The Smith-Waterman algorithm for local sequence alignment is more sensitive than heuristic methods for database searching, but also more time-consuming. The fastest approach to parallelisation with SIMD technology has previously been described by Farrar in 2007. The aim of this study was to explore whether further speed could be gained by other approaches to parallelisation. Results A faster approach and implementation is described and benchmarked. In the new tool SWIPE, residues from sixteen different database sequences are compared in parallel to one query residue. Using a 375 residue query sequence a speed of 106 billion cell updates per second (GCUPS) was achieved on a dual Intel Xeon X5650 six-core processor system, which is over six times more rapid than software based on Farrar's 'striped' approach. SWIPE was about 2.5 times faster when the programs used only a single thread. For shorter queries, the increase in speed was larger. SWIPE was about twice as fast as BLAST when using the BLOSUM50 score matrix, while BLAST was about twice as fast as SWIPE for the BLOSUM62 matrix. The software is designed for 64 bit Linux on processors with SSSE3. Source code is available from http://dna.uio.no/swipe/ under the GNU Affero General Public License. Conclusions Efficient parallelisation using SIMD on standard hardware makes it possible to run Smith-Waterman database searches more than six times faster than before. The approach described here could significantly widen the potential application of Smith-Waterman searches. Other applications that require optimal local alignment scores could also benefit from improved performance. PMID:21631914
Faster Smith-Waterman database searches with inter-sequence SIMD parallelisation.
Rognes, Torbjørn
2011-06-01
The Smith-Waterman algorithm for local sequence alignment is more sensitive than heuristic methods for database searching, but also more time-consuming. The fastest approach to parallelisation with SIMD technology has previously been described by Farrar in 2007. The aim of this study was to explore whether further speed could be gained by other approaches to parallelisation. A faster approach and implementation is described and benchmarked. In the new tool SWIPE, residues from sixteen different database sequences are compared in parallel to one query residue. Using a 375 residue query sequence a speed of 106 billion cell updates per second (GCUPS) was achieved on a dual Intel Xeon X5650 six-core processor system, which is over six times more rapid than software based on Farrar's 'striped' approach. SWIPE was about 2.5 times faster when the programs used only a single thread. For shorter queries, the increase in speed was larger. SWIPE was about twice as fast as BLAST when using the BLOSUM50 score matrix, while BLAST was about twice as fast as SWIPE for the BLOSUM62 matrix. The software is designed for 64 bit Linux on processors with SSSE3. Source code is available from http://dna.uio.no/swipe/ under the GNU Affero General Public License. Efficient parallelisation using SIMD on standard hardware makes it possible to run Smith-Waterman database searches more than six times faster than before. The approach described here could significantly widen the potential application of Smith-Waterman searches. Other applications that require optimal local alignment scores could also benefit from improved performance.
Grigg, G C; Seebacher, F
1999-01-01
The discovery that changes in heart rate and blood flow allow some reptiles to heat faster than they cool has become a central paradigm in our understanding of reptilian thermoregulation. However, this hysteresis in heart rate has been demonstrated only in simplistic laboratory heating and cooling trials, leaving its functional significance in free-ranging animals unproven. To test the validity of this paradigm, we measured heart rate and body temperature (Tb) in undisturbed, free-ranging bearded dragons (Pogona barbata), the species in which this phenomenon was first described. Our field data confirmed the paradigm and we found that heart rate during heating usually exceeded heart rate during cooling at any Tb. Importantly, however, we discovered that heart rate was proportionally faster in cool lizards whose Tb was still well below the 'preferred Tb range' compared to lizards whose Tb was already close to it. Similarly, heart rate during cooling was proportionally slower the warmer the lizard and the greater its cooling potential compared to lizards whose Tb was already near minimum operative temperature. Further, we predicted that, if heart rate hysteresis has functional significance, a 'reverse hysteresis' pattern should be observable when lizards risked overheating. This was indeed the case and, during heating on those occasions when Tb reached very high levels (> 40 degrees C), heart rate was significantly lower than heart rate during the immediately following cooling phase. These results demonstrate that physiological control of thermoregulation in reptiles is more complex than has been previously recognized. PMID:10418165
The Case for Intelligent Propulsion Control for Fast Engine Response
NASA Technical Reports Server (NTRS)
Litt, Jonathan S.; Frederick, Dean K.; Guo, Ten-Huei
2009-01-01
Damaged aircraft have occasionally had to rely solely on thrust to maneuver as a consequence of losing hydraulic power needed to operate flight control surfaces. The lack of successful landings in these cases inspired research into more effective methods of utilizing propulsion-only control. That research demonstrated that one of the major contributors to the difficulty in landing is the slow response of the engines as compared to using traditional flight control. To address this, research is being conducted into ways of making the engine more responsive under emergency conditions. This can be achieved by relaxing controller limits, adjusting schedules, and/or redesigning the regulators to increase bandwidth. Any of these methods can enable faster response at the potential expense of engine life and increased likelihood of stall. However, an example sensitivity analysis revealed a complex interaction of the limits and the difficulty in predicting the way to achieve the fastest response. The sensitivity analysis was performed on a realistic engine model, and demonstrated that significantly faster engine response can be achieved compared to standard Bill of Material control. However, the example indicates the need for an intelligent approach to controller limit adjustment in order for the potential to be fulfilled.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-16
... be inspected, between 10 a.m. and 4 p.m., in the FinCEN reading room in Vienna, VA. Persons wishing... submission; faster routing of information to law enforcement; greater data security and privacy compared with... suspicious activity report (SAR) was filed; Feedback reports to filers; Faster receipt for money services...
Attentional Orienting towards Emotion: P2 and N400 ERP Effects
ERIC Educational Resources Information Center
Kanske, Philipp; Plitschka, Jan; Kotz, Sonja A.
2011-01-01
Attention can be oriented to different spatial locations yielding faster processing of attended compared to unattended stimuli. Similarly attention can be oriented to a semantic category such as "animals" or "tools". Words from the attended category will also be recognized faster than words from an unattended category. Here, we asked whether it is…
Scullin, Michael K; Krueger, Madison L; Ballard, Hannah K; Pruett, Natalya; Bliwise, Donald L
2018-01-01
Bedtime worry, including worrying about incomplete future tasks, is a significant contributor to difficulty falling asleep. Previous research showed that writing about one's worries can help individuals fall asleep. We investigated whether the temporal focus of bedtime writing-writing a to-do list versus journaling about completed activities-affected sleep onset latency. Fifty-seven healthy young adults (18-30) completed a writing assignment for 5 min prior to overnight polysomnography recording in a controlled sleep laboratory. They were randomly assigned to write about tasks that they needed to remember to complete the next few days (to-do list) or about tasks they had completed the previous few days (completed list). Participants in the to-do list condition fell asleep significantly faster than those in the completed-list condition. The more specifically participants wrote their to-do list, the faster they subsequently fell asleep, whereas the opposite trend was observed when participants wrote about completed activities. Therefore, to facilitate falling asleep, individuals may derive benefit from writing a very specific to-do list for 5 min at bedtime rather than journaling about completed activities. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Qin, Zhenxia; Dimitrijevic, Aleksandra; Aswad, Dana W
2015-02-01
Isoaspartate formation is a common type of protein damage normally kept in check by the repair enzyme protein-L-isoaspartyl methyltransferase (PIMT). Mice with a knockout of the gene (Pcmt1) for this enzyme (KO, -/-) exhibit a pronounced neuropathology with fatal epileptic seizures at 30-60 days. Heterozygous (HZ, +/-) mice have 50% of the PIMT activity found in wild-type (WT, +/+) mice, but appear normal. To see if HZ mice exhibit accelerated aging at the molecular level, we compared brain extracts from HZ and WT mice at 8 months and 2 years with regard to PIMT activity, isoaspartate levels, and activity of an endogenous PIMT substrate, creatine kinase B. PIMT activity declined modestly with age in both genotypes. Isoaspartate was significantly higher in HZ than WT mice at 8 months and more so at 2 years, rising 5× faster in HZ males and 3× faster in females. Creatine kinase activity decreased with age and was always lower in the HZ mice. These findings suggest the individual variation of human PIMT levels may significantly influence the course of age-related central nervous system dysfunction. Copyright © 2015 Elsevier Inc. All rights reserved.
Motes, Michael A; Yezhuvath, Uma S; Aslan, Sina; Spence, Jeffrey S; Rypma, Bart; Chapman, Sandra B
2018-02-01
Higher-order cognitive training has shown to enhance performance in older adults, but the neural mechanisms underlying performance enhancement have yet to be fully disambiguated. This randomized trial examined changes in processing speed and processing speed-related neural activity in older participants (57-71 years of age) who underwent cognitive training (CT, N = 12) compared with wait-listed (WLC, N = 15) or exercise-training active (AC, N = 14) controls. The cognitive training taught cognitive control functions of strategic attention, integrative reasoning, and innovation over 12 weeks. All 3 groups worked through a functional magnetic resonance imaging processing speed task during 3 sessions (baseline, mid-training, and post-training). Although all groups showed faster reaction times (RTs) across sessions, the CT group showed a significant increase, and the WLC and AC groups showed significant decreases across sessions in the association between RT and BOLD signal change within the left prefrontal cortex (PFC). Thus, cognitive training led to a change in processing speed-related neural activity where faster processing speed was associated with reduced PFC activation, fitting previously identified neural efficiency profiles. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
The behavior of an opponent alters pacing decisions in 4-km cycling time trials.
Konings, Marco J; Schoenmakers, Patrick P J M; Walker, Andrew J; Hettinga, Florentina J
2016-05-01
The present study aimed to explore how athletes respond to different behaviors of their opponents. Twelve moderately to highly physically active participants with at least two years of cycling experience completed four 4-km time trials on a Velotron cycle ergometer. After a familiarization time trial (FAM), participants performed three experimental time trials in randomized order with no opponent (NO), a virtual opponent who started slower and finished faster compared to FAM (OP-SLOWFAST), or a virtual opponent who started faster and finished slower compared to FAM (OP-FASTSLOW). Repeated-measures ANOVAs (P<0.05) were used to examine differences in pacing and performance related to power output, velocity and RPE. OP-SLOWFAST and OP-FASTSLOW were completed faster compared to NO (385.5±27.5, 385.0±28.6, and 390.6±29.3s, respectively). An interaction effect for condition×distance (F=3.944, P<0.001) indicated differences in pacing profiles between conditions. Post-hoc analysis revealed that a less aggressive starting strategy was adopted in NO compared to OP-FASTSLOW and OP-SLOWFAST during the initial 1000m. Finally, a faster starting opponent evokes higher power outputs by the participants in the initial 750m compared to a slower starting opponent. The present study is the first to show that the behavior of an opponent affects pacing-related decisions in laboratory-controlled conditions. Our findings support the recently proposed interdependence of perception and action, and emphasize the interaction with the environment as an important determinant for an athlete's pacing decisions, especially during the initial stages of a race. Copyright © 2016 Elsevier Inc. All rights reserved.
Rate and Pattern of Rim Area Loss in Healthy and Progressing Glaucoma Eyes
Hammel, Na’ama; Belghith, Akram; Bowd, Christopher; Medeiros, Felipe A.; Sharpsten, Lucie; Mendoza, Nadia; Tatham, Andrew J.; Khachatryan, Naira; Liebmann, Jeffrey M.; Girkin, Christopher A.; Weinreb, Robert N.; Zangwill, Linda M.
2015-01-01
Objective To characterize the rate and pattern of age-related and glaucomatous neuroretinal rim area changes in subjects of African descent (AD) and European descent (ED). Design Prospective longitudinal study. Subjects 296 eyes of 157 healthy subjects (88 AD and 69 ED) and 73 progressing glaucoma eyes of 67 subjects (24 AD and 43 ED) from the Diagnostic Innovations in Glaucoma Study (DIGS) and the African Descent and Glaucoma Evaluation Study (ADAGES) were included. Methods Global and sectoral rim area was measured using confocal laser scanning ophthalmoscopy (CSLO). Progression of glaucomatous optic disc damage was determined by masked stereophoto review. The rates of absolute rim area loss and percent rim area loss in healthy and progressing glaucomatous eyes were compared using multivariable nested mixed-effects models. Main Outcome Measures Rate of rim area loss over time. Results The median (inter-quartile range) follow-up time was 5.0 years (2.0–7.4) for healthy eyes and 8.3 years (7.5–9.9) for progressing glaucoma eyes. The mean rate of global rim area loss was significantly faster in progressing glaucoma eyes compared with healthy eyes for both rim area loss (−10.2 ×10−3 mm2/year vs. −2.8 ×10−3 mm2/year, respectively, P<.001) and percent rim area loss (−1.1 %/year vs. −0.2 %/year, respectively, P<.001), but there was considerable overlap between the two groups. 63% of progressing glaucoma eyes had a rate of change faster than the 5th quantile of healthy eyes. For both healthy and progressing eyes, the pattern of rim area loss and percent rim area loss was similar; it tended to be fastest in the superior temporal and inferior temporal sectors. The rate of change was similar in AD and ED progressing eyes. Conclusions Compared with healthy eyes, the mean rate of global rim area loss was 3.7 times faster and the mean rate of global percent rim area loss was 5.4 times faster in progressing glaucoma eyes. A reference database of healthy eyes can be used to help clinicians distinguish age-related rim area loss from rim area loss due to glaucoma. PMID:26746597
Auditory perceptual simulation: Simulating speech rates or accents?
Zhou, Peiyun; Christianson, Kiel
2016-07-01
When readers engage in Auditory Perceptual Simulation (APS) during silent reading, they mentally simulate characteristics of voices attributed to a particular speaker or a character depicted in the text. Previous research found that auditory perceptual simulation of a faster native English speaker during silent reading led to shorter reading times that auditory perceptual simulation of a slower non-native English speaker. Yet, it was uncertain whether this difference was triggered by the different speech rates of the speakers, or by the difficulty of simulating an unfamiliar accent. The current study investigates this question by comparing faster Indian-English speech and slower American-English speech in the auditory perceptual simulation paradigm. Analyses of reading times of individual words and the full sentence reveal that the auditory perceptual simulation effect again modulated reading rate, and auditory perceptual simulation of the faster Indian-English speech led to faster reading rates compared to auditory perceptual simulation of the slower American-English speech. The comparison between this experiment and the data from Zhou and Christianson (2016) demonstrate further that the "speakers'" speech rates, rather than the difficulty of simulating a non-native accent, is the primary mechanism underlying auditory perceptual simulation effects. Copyright © 2016 Elsevier B.V. All rights reserved.
Effects of low-level SO/sub 2/ on Usnes hirta and Parmelia chlorachroa
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eversman, S.
1978-01-01
Respiration rates of Usnea hirta (l.) wigg, and Parmelia chlorochroa tuck exposed in the field to SO/sub 2/ fumigation decreased significantly, compared to control rates, within 30 days at 94 ppB SO/sub 2/ and within 60 days at 33 ppB. Nearly 100% of the algal cells were plasmolyzed within 60 days. The respiration rates of P. chlorochora samples were not significantly different from those of conrol samples after 60 days of exposure to 18 ppB SO/sub 2/. The respiration rates of U. hirta samples were significantly less than those of control samples after 96 days of exposure to 18 ppBmore » SO/sub 2/. A significantly greater percentage of the algal cells were plasmolyzed in U. hirta and P. chlorochroa, compared to control samples, after 31 days of exposure to 18 ppB. Damage to the lichens was more obvious and occurred faster than damage to adjacent vascular vegetation.« less
Tournaki, Nelly
2003-01-01
Forty-two second-grade general education students and 42 students with learning disabilities (LD) were taught basic, one-digit addition facts (e.g., 5 + 3 = _). Students received instruction via (a) a minimum addend strategy, (b) drill and practice, or (c) control. The effectiveness of the two methods was measured through students' accuracy and latency scores on a posttest and a transfer task (e.g., 5 + 3 + 7 =_). Students with LD improved significantly only in the strategy condition, as compared to drill-and-practice and control conditions, whereas general education students improved significantly both in the strategy and the drill-and-practice conditions as compared to the control condition. However, in the transfer task, students from all groups became significantly more accurate only in the strategy condition, while all students were significantly faster than their control group peers regardless of teaching method. The implications for teachers' differential choices of methods of instruction for students with different learning characteristics are discussed.
Faiz, Seyed Hamid Reza; Imani, Farnad; Rahimzadeh, Poupak; Alebouyeh, Mahmoud Reza; Entezary, Saeed Reza; Shafeinia, Amineh
2017-08-01
Peripheral nerve block is an accepted method in lower limb surgeries regarding its convenience and good tolerance by the patients. Quick performance and fast sensory and motor block are highly demanded in this method. The aim of the present study was to compare 2 different methods of sciatic and tibial-peroneal nerve block in lower limb surgeries in terms of block onset. In this clinical trial, 52 candidates for elective lower limb surgery were randomly divided into 2 groups: sciatic nerve block before bifurcation (SG; n = 27) and separate tibial-peroneal nerve block (TPG; n = 25) under ultrasound plus nerve stimulator guidance. The mean duration of block performance, as well as complete sensory and motor block, was recorded and compared between the groups. The mean duration of complete sensory block in the SG and TPG groups was 35.4 ± 4.1 and 24.9 ± 4.2 minutes, respectively, which was significantly lower in the TPG group (P = 0.001). The mean duration of complete motor block in the SG and TPG groups was 63.3 ± 4.4 and 48.4 ± 4.6 minutes, respectively, which was significantly lower in the TPG group (P = 0.001). No nerve injuries, paresthesia, or other possible side effects were reported in patients. According to the present study, it seems that TPG shows a faster sensory and motor block than SG.
A comparison of caffeine versus pseudoephedrine on cycling time-trial performance.
Spence, Angela L; Sim, Marc; Landers, Grant; Peeling, Peter
2013-10-01
Both caffeine (CAF) and pseudoephedrine (PSE) are proposed to be central nervous system stimulants. However, during competition, CAF is a permitted substance, whereas PSE is a banned substance at urinary levels >150 μg · ml(-1). As a result, this study aimed to compare the effect of CAF versus PSE use on cycling time trial (TT) performance to explore whether the legal stimulant was any less ergogenic than the banned substance. Here, 10 well-trained male cyclists or triathletes were recruited for participation. All athletes were required to attend the laboratory on four separate occasions--including a familiarization trial and three experimental trials, which required participants to complete a simulated 40 km (1,200 kJ) cycling TT after the ingestion of either 200 mg CAF, 180 mg PSE or a nonnutritive placebo (PLA). The results showed that the total time taken and the mean power produced during each TT was not significantly different (p > .05) between trials, despite a 1.3% faster overall time (~57 s) after CAF consumption. Interestingly, the time taken to complete the second half of the TT was significantly faster (p < .05) in CAF as compared with PSE (by 99 s), with magnitude based inferences suggesting a 91% beneficial effect of CAF during the second half of the TT. This investigation further confirms the ergogenic benefits of CAF use during TT performances and further suggests this legal CNS stimulant has a better influence than a supra-therapeutic dose of PSE.
A comparison of classical histology to anatomy revealed by hard x-rays
NASA Astrophysics Data System (ADS)
Richter, Claus-Peter; Tan, Xiaodong; Young, Hunter; Stock, Stuart; Robinson, Alan; Byskosh, Orest; Zheng, Jing; Soriano, Carmen; Xiao, Xianghui; Whitlon, Donna
2016-10-01
Many diseases trigger morphological changes in affected tissue. Today, classical histology is still the "gold standard" used to study and describe those changes. Classical histology, however, is time consuming and requires chemical tissue manipulations that can result in significant tissue distortions. It is sometimes difficult to separate tissue-processing artifacts from changes caused by the disease process. We show that synchrotron X-ray phase-contrast micro-computed tomography (micro-CT) can be used to examine non-embedded, hydrated tissue at a resolution comparable to that obtained with classical histology. The data analysis from stacks of reconstructed micro-CT images is more flexible and faster than when using the classical, physically embedded sections that are by necessity fixed in a particular orientation. We show that in a three-dimensional (3D) structure with meticulous structural details such as the cochlea and the kidney, micro-CT is more flexible, faster and more convenient for morphological studies and disease diagnoses.
Development of Novel Faster-Dissolving Microneedle Patches for Transcutaneous Vaccine Delivery
Ono, Akihiko; Ito, Sayami; Sakagami, Shun; Saito, Mio; Quan, Ying-Shu; Kamiyama, Fumio; Hirobe, Sachiko; Okada, Naoki
2017-01-01
Microneedle (MN) patches are promising for transcutaneous vaccination because they enable vaccine antigens to physically penetrate the stratum corneum via low-invasive skin puncturing, and to be effectively delivered to antigen-presenting cells in the skin. In second-generation MN patches, the dissolving MNs release the loaded vaccine antigen into the skin. To shorten skin application time for clinical practice, this study aims to develop novel faster-dissolving MNs. We designed two types of MNs made from a single thickening agent, carboxymethylcellulose (CMC) or hyaluronan (HN). Both CMC-MN and HN-MN completely dissolved in rat skin after a 5-min application. In pre-clinical studies, both MNs could demonstrably increase antigen-specific IgG levels after vaccination and prolong antigen deposition compared with conventional injections, and deliver antigens into resected human dermal tissue. In clinical research, we demonstrated that both MNs could reliably and safely puncture human skin without any significant skin irritation from transepidermal water loss measurements and ICDRG (International Contact Dermatitis Research Group) evaluation results. PMID:28771172
Elephants born in the high stress season have faster reproductive ageing.
Mumby, Hannah S; Mar, Khyne U; Hayward, Adam D; Htut, Win; Htut-Aung, Ye; Lummaa, Virpi
2015-09-14
Senescent declines in reproduction and survival are found across the tree of life, but little is known of the factors causing individual variation in reproductive ageing rates. One contributor may be variation in early developmental conditions, but only a few studies quantify the effects of early environment on reproductive ageing and none concern comparably long-lived species to humans. We determine the effects of 'stressful' birth conditions on lifetime reproduction in a large semi-captive population of Asian elephants (Elephas maximus). We categorise birth month into stressful vs. not-stressful periods based on longitudinal measures of glucocorticoid metabolites in reproductive-aged females, which peak during heavy workload and the start of the monsoon in June-August. Females born in these months exhibit faster reproductive senescence in adulthood and have significantly reduced lifetime reproductive success than their counterparts born at other times of year. Improving developmental conditions could therefore delay reproductive ageing in species as long-lived as humans.
Comparison of three explicit multigrid methods for the Euler and Navier-Stokes equations
NASA Technical Reports Server (NTRS)
Chima, Rodrick V.; Turkel, Eli; Schaffer, Steve
1987-01-01
Three explicit multigrid methods, Ni's method, Jameson's finite-volume method, and a finite-difference method based on Brandt's work, are described and compared for two model problems. All three methods use an explicit multistage Runge-Kutta scheme on the fine grid, and this scheme is also described. Convergence histories for inviscid flow over a bump in a channel for the fine-grid scheme alone show that convergence rate is proportional to Courant number and that implicit residual smoothing can significantly accelerate the scheme. Ni's method was slightly slower than the implicitly-smoothed scheme alone. Brandt's and Jameson's methods are shown to be equivalent in form but differ in their node versus cell-centered implementations. They are about 8.5 times faster than Ni's method in terms of CPU time. Results for an oblique shock/boundary layer interaction problem verify the accuracy of the finite-difference code. All methods slowed considerably on the stretched viscous grid but Brandt's method was still 2.1 times faster than Ni's method.
Elephants born in the high stress season have faster reproductive ageing
Mumby, Hannah S.; Mar, Khyne U.; Hayward, Adam D.; Htut, Win; Htut-Aung, Ye; Lummaa, Virpi
2015-01-01
Senescent declines in reproduction and survival are found across the tree of life, but little is known of the factors causing individual variation in reproductive ageing rates. One contributor may be variation in early developmental conditions, but only a few studies quantify the effects of early environment on reproductive ageing and none concern comparably long-lived species to humans. We determine the effects of ‘stressful’ birth conditions on lifetime reproduction in a large semi-captive population of Asian elephants (Elephas maximus). We categorise birth month into stressful vs. not-stressful periods based on longitudinal measures of glucocorticoid metabolites in reproductive-aged females, which peak during heavy workload and the start of the monsoon in June-August. Females born in these months exhibit faster reproductive senescence in adulthood and have significantly reduced lifetime reproductive success than their counterparts born at other times of year. Improving developmental conditions could therefore delay reproductive ageing in species as long-lived as humans. PMID:26365592
Computed Tomography Window Blending: Feasibility in Thoracic Trauma.
Mandell, Jacob C; Wortman, Jeremy R; Rocha, Tatiana C; Folio, Les R; Andriole, Katherine P; Khurana, Bharti
2018-02-07
This study aims to demonstrate the feasibility of processing computed tomography (CT) images with a custom window blending algorithm that combines soft-tissue, bone, and lung window settings into a single image; to compare the time for interpretation of chest CT for thoracic trauma with window blending and conventional window settings; and to assess diagnostic performance of both techniques. Adobe Photoshop was scripted to process axial DICOM images from retrospective contrast-enhanced chest CTs performed for trauma with a window-blending algorithm. Two emergency radiologists independently interpreted the axial images from 103 chest CTs with both blended and conventional windows. Interpretation time and diagnostic performance were compared with Wilcoxon signed-rank test and McNemar test, respectively. Agreement with Nexus CT Chest injury severity was assessed with the weighted kappa statistic. A total of 13,295 images were processed without error. Interpretation was faster with window blending, resulting in a 20.3% time saving (P < .001), with no difference in diagnostic performance, within the power of the study to detect a difference in sensitivity of 5% as determined by post hoc power analysis. The sensitivity of the window-blended cases was 82.7%, compared to 81.6% for conventional windows. The specificity of the window-blended cases was 93.1%, compared to 90.5% for conventional windows. All injuries of major clinical significance (per Nexus CT Chest criteria) were correctly identified in all reading sessions, and all negative cases were correctly classified. All readers demonstrated near-perfect agreement with injury severity classification with both window settings. In this pilot study utilizing retrospective data, window blending allows faster preliminary interpretation of axial chest CT performed for trauma, with no significant difference in diagnostic performance compared to conventional window settings. Future studies would be required to assess the utility of window blending in clinical practice. Copyright © 2018 The Association of University Radiologists. All rights reserved.
Ivanecz, Arpad; Krebs, Bojan; Stozer, Andraz; Jagric, Tomaz; Plahuta, Irena; Potrc, Stojan
2018-03-01
The aim of the study was to compare the outcome of pure laparoscopic and open simultaneous resection of both the primary colorectal cancer and synchronous colorectal liver metastases (SCLM). From 2000 to 2016 all patients treated by simultaneous resection were assessed for entry in this single center, clinically nonrandomized trial. A propensity score matching was used to compare the laparoscopic group (LAP) to open surgery group (OPEN). Primary endpoints were perioperative and oncologic outcomes. Secondary endpoints were overall survival (OS) and disease-free survival (DFS). Of the 82 patients identified who underwent simultaneous liver resection for SCLM, 10 patients underwent LAP. All these consecutive patients from LAP were matched to 10 comparable OPEN. LAP reduced the length of hospital stay (P = 0.044) and solid food oral intake was faster (P = 0.006) in this group. No patient undergoing the laparoscopic procedure experienced conversion to the open technique. No difference was observed in operative time, blood loss, transfusion rate, narcotics requirement, clinical risk score, resection margin, R0 resections rate, morbidity, mortality and incisional hernias rate. The two groups did not differ significantly in terms of the 3-year OS rate (90 vs. 75%; P = 0.842) and DFS rate (60 vs. 57%; P = 0.724). LAP reduced the length of hospital stay and offers faster solid food oral intake. Comparable oncologic and survival outcomes can be achieved. LAP is beneficial for well selected patients in high volume centers with appropriate expertise.
Borel, F; Gaudin, C; Duchalais, E; Lehur, P-A; Meurette, G
2017-12-01
To assess the impact of a simple flap closing procedure by Karydakis flap (KF) after pilonidal sinus excision on the costs and healing time as compared to routine lay-open technique. Out of 44 consecutive patients operated on for pilonidal excision (November 2013-March 2015), 17 had a Karydakis flap and 27 a lay-open procedure. For each patient, the length of stay, the operating time (OT), the time needed for complete healing and postoperative care resources were recorded. The global costs included OT, nursing care quantity, and modalities until complete scar healing. One reoperation in the lay-open group was necessary during the follow-up (8±5months). No recurrence occurred. Postoperative morbidity was similar in both groups. Results showed that KF global cost was inferior as compared to lay-open technique (941±178€ vs. 1601±399€; P=0.0001), KF healed faster (32±17 vs. 59±22days; P=0.0001), whereas OT was longer in KF group (16±7 vs. 25±4min; P=0.001). KF allows a faster healing time and a 41% lower cost than lay-open technique. Preferential use of KF rather than lay-open procedure could allow a significant health cost saving. Copyright © 2017. Published by Elsevier Masson SAS.
Go East for Better Honey Bee Health: Apis cerana Is Faster at Hygienic Behavior than A. mellifera.
Lin, Zheguang; Page, Paul; Li, Li; Qin, Yao; Zhang, Yingying; Hu, Fuliang; Neumann, Peter; Zheng, Huoqing; Dietemann, Vincent
2016-01-01
The poor health status of the Western honey bee, Apis mellifera, compared to its Eastern counterpart, Apis cerana, is remarkable. This has been attributed to lower pathogen prevalence in A. cerana colonies and to their ability to survive infestations with the ectoparasitic mite, Varroa destructor. These properties have been linked to an enhanced removal of dead or unhealthy immature bees by adult workers in this species. Although such hygienic behavior is known to contribute to honey bee colony health, comparative data of A. mellifera and A. cerana in performing this task are scarce. Here, we compare for the first time the removal of freeze-killed brood in one population of each species and over two seasons in China. Our results show that A. cerana was significantly faster than A. mellifera at both opening cell caps and removing freeze-killed brood. The fast detection and removal of diseased brood is likely to limit the proliferation of pathogenic agents. Given our results can be generalized to the species level, a rapid hygienic response could contribute to the better health of A. cerana. Promoting the fast detection and removal of worker brood through adapted breeding programs could further improve the social immunity of A. mellifera colonies and contribute to a better health status of the Western honey bee worldwide.
Go East for Better Honey Bee Health: Apis cerana Is Faster at Hygienic Behavior than A. mellifera
Li, Li; Qin, Yao; Zhang, Yingying; Hu, Fuliang; Neumann, Peter; Zheng, Huoqing; Dietemann, Vincent
2016-01-01
The poor health status of the Western honey bee, Apis mellifera, compared to its Eastern counterpart, Apis cerana, is remarkable. This has been attributed to lower pathogen prevalence in A. cerana colonies and to their ability to survive infestations with the ectoparasitic mite, Varroa destructor. These properties have been linked to an enhanced removal of dead or unhealthy immature bees by adult workers in this species. Although such hygienic behavior is known to contribute to honey bee colony health, comparative data of A. mellifera and A. cerana in performing this task are scarce. Here, we compare for the first time the removal of freeze-killed brood in one population of each species and over two seasons in China. Our results show that A. cerana was significantly faster than A. mellifera at both opening cell caps and removing freeze-killed brood. The fast detection and removal of diseased brood is likely to limit the proliferation of pathogenic agents. Given our results can be generalized to the species level, a rapid hygienic response could contribute to the better health of A. cerana. Promoting the fast detection and removal of worker brood through adapted breeding programs could further improve the social immunity of A. mellifera colonies and contribute to a better health status of the Western honey bee worldwide. PMID:27606819
Cheng, Yuk Wah; Wilkinson, Jenny M
2015-08-01
This paper reports on an evaluation of the introduction of a blood bank automation system (Ortho AutoVue(®) Innova) in a hospital blood bank by considering the performance and workflow as compared with manual methods. The turnaround time was found to be 45% faster than the manual method. The concordance rate was found to be 100% for both ABO/Rh(D) typing and antibody screening in both of the systems and there was no significant difference in detection sensitivity for clinically significant antibodies. The Ortho AutoVue(®) Innova automated blood banking system streamlined the routine pre-transfusion testing in hospital blood bank with high throughput, equivalent sensitivity and reliability as compared with conventional manual method. Copyright © 2015 Elsevier Ltd. All rights reserved.
When listening to rain sounds boosts arithmetic ability
De Benedetto, Francesco; Ferrari, Maria Vittoria; Ferrarini, Giorgia
2018-01-01
Studies in the literature have provided conflicting evidence about the effects of background noise or music on concurrent cognitive tasks. Some studies have shown a detrimental effect, while others have shown a beneficial effect of background auditory stimuli. The aim of this study was to investigate the influence of agitating, happy or touching music, as opposed to environmental sounds or silence, on the ability of non-musician subjects to perform arithmetic operations. Fifty university students (25 women and 25 men, 25 introverts and 25 extroverts) volunteered for the study. The participants were administered 180 easy or difficult arithmetic operations (division, multiplication, subtraction and addition) while listening to heavy rain sounds, silence or classical music. Silence was detrimental when participants were faced with difficult arithmetic operations, as it was associated with significantly worse accuracy and slower RTs than music or rain sound conditions. This finding suggests that the benefit of background stimulation was not music-specific but possibly due to an enhanced cerebral alertness level induced by the auditory stimulation. Introverts were always faster than extroverts in solving mathematical problems, except when the latter performed calculations accompanied by the sound of heavy rain, a condition that made them as fast as introverts. While the background auditory stimuli had no effect on the arithmetic ability of either group in the easy condition, it strongly affected extroverts in the difficult condition, with RTs being faster during agitating or joyful music as well as rain sounds, compared to the silent condition. For introverts, agitating music was associated with faster response times than the silent condition. This group difference may be explained on the basis of the notion that introverts have a generally higher arousal level compared to extroverts and would therefore benefit less from the background auditory stimuli. PMID:29466472
Disease course in patients with autosomal recessive retinitis pigmentosa due to the USH2A gene.
Sandberg, Michael A; Rosner, Bernard; Weigel-DiFranco, Carol; McGee, Terri L; Dryja, Thaddeus P; Berson, Eliot L
2008-12-01
To estimate the mean rates of ocular function loss in patients with autosomal recessive retinitis pigmentosa due to USH2A mutations. In 125 patients with USH2A mutations, longitudinal regression was used to estimate mean rates of change in Snellen visual acuity, Goldmann visual field area (V4e white test light), and 30-Hz (cone) full-field electroretinogram amplitude. These rates were compared with those of previously studied cohorts with dominant retinitis pigmentosa due to RHO mutations and with X-linked retinitis pigmentosa due to RPGR mutations. Rates of change in patients with the Cys759Phe mutation, the USH2A mutation associated with nonsyndromic disease, were compared with rates of change in patients with the Glu767fs mutation, the most common USH2A mutation associated with Usher syndrome type II (i.e., retinitis pigmentosa and hearing loss). Mean annual exponential rates of decline for the USH2A patients were 2.6% for visual acuity, 7.0% for visual field area, and 13.2% for electroretinogram amplitude. The rate of acuity loss fell between the corresponding rates for the RHO and RPGR patients, whereas the rates for field and ERG amplitude loss were faster than those for the RHO and RPGR patients. No significant differences were found for patients with the Cys759Phe mutation versus patients with the Glu767fs mutation. On average, USH2A patients lose visual acuity faster than RHO patients and slower than RPGR patients. USH2A patients lose visual field and cone electroretinogram amplitude faster than patients with RHO or RPGR mutations. Patients with a nonsyndromic USH2A mutation have the same retinal disease course as patients with syndromic USH2A disease.
When listening to rain sounds boosts arithmetic ability.
Proverbio, Alice Mado; De Benedetto, Francesco; Ferrari, Maria Vittoria; Ferrarini, Giorgia
2018-01-01
Studies in the literature have provided conflicting evidence about the effects of background noise or music on concurrent cognitive tasks. Some studies have shown a detrimental effect, while others have shown a beneficial effect of background auditory stimuli. The aim of this study was to investigate the influence of agitating, happy or touching music, as opposed to environmental sounds or silence, on the ability of non-musician subjects to perform arithmetic operations. Fifty university students (25 women and 25 men, 25 introverts and 25 extroverts) volunteered for the study. The participants were administered 180 easy or difficult arithmetic operations (division, multiplication, subtraction and addition) while listening to heavy rain sounds, silence or classical music. Silence was detrimental when participants were faced with difficult arithmetic operations, as it was associated with significantly worse accuracy and slower RTs than music or rain sound conditions. This finding suggests that the benefit of background stimulation was not music-specific but possibly due to an enhanced cerebral alertness level induced by the auditory stimulation. Introverts were always faster than extroverts in solving mathematical problems, except when the latter performed calculations accompanied by the sound of heavy rain, a condition that made them as fast as introverts. While the background auditory stimuli had no effect on the arithmetic ability of either group in the easy condition, it strongly affected extroverts in the difficult condition, with RTs being faster during agitating or joyful music as well as rain sounds, compared to the silent condition. For introverts, agitating music was associated with faster response times than the silent condition. This group difference may be explained on the basis of the notion that introverts have a generally higher arousal level compared to extroverts and would therefore benefit less from the background auditory stimuli.
Trans advanced surface laser ablation (TransPRK) outcomes using SmartPulseTechnology.
Aslanides, Ioannis M; Kymionis, George D
2017-02-01
To evaluate early visual rehabilitation, post-operative pain, epithelial healing and haze after transepithelial photorefractive keratectomy (TransPRK) using the SmartPulseTechnology (SPT) of Schwind Amaris (Schwind eye-tech-solutions GmbH, Kleinostheim, Germany). This was a retrospective comparative evaluation of a cohort of myopic patients undergoing TransPRK with SPT (group 1), with one matched control group that underwent conventional TransPRK (group 2). All cases had a 6-month post-operative follow-up including visual acuity and slit-lamp examination. Subjective evaluation of pain was recorded post-operatively. 49 eyes of 25 patients in group 1 and 40 eyes of 20 patients in group 2 were enrolled. The patients' visual rehabilitation was significantly faster in group 1, one day and one week post-operatively (P<0.05). From one month onward there was no significant difference between the groups. The epithelial defect size was significantly smaller on post-operative days 1 and 2 for group 1 (P<0.05 in both cases). The pain score was also significantly less in group 1 (P<0.05). The haze level had no significant difference between the groups at any post-operative point (P>0.05). TransPRK using SPT provides promising results in the early post-operative period. Visual rehabilitation, re-epithelialization and pain were faster in the early post-operative period in group 1 in comparison with group 2. Haze formation was not significantly different between the two groups; however, it was consistently less in group 1. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Reverse engineering a gene network using an asynchronous parallel evolution strategy
2010-01-01
Background The use of reverse engineering methods to infer gene regulatory networks by fitting mathematical models to gene expression data is becoming increasingly popular and successful. However, increasing model complexity means that more powerful global optimisation techniques are required for model fitting. The parallel Lam Simulated Annealing (pLSA) algorithm has been used in such approaches, but recent research has shown that island Evolutionary Strategies can produce faster, more reliable results. However, no parallel island Evolutionary Strategy (piES) has yet been demonstrated to be effective for this task. Results Here, we present synchronous and asynchronous versions of the piES algorithm, and apply them to a real reverse engineering problem: inferring parameters in the gap gene network. We find that the asynchronous piES exhibits very little communication overhead, and shows significant speed-up for up to 50 nodes: the piES running on 50 nodes is nearly 10 times faster than the best serial algorithm. We compare the asynchronous piES to pLSA on the same test problem, measuring the time required to reach particular levels of residual error, and show that it shows much faster convergence than pLSA across all optimisation conditions tested. Conclusions Our results demonstrate that the piES is consistently faster and more reliable than the pLSA algorithm on this problem, and scales better with increasing numbers of nodes. In addition, the piES is especially well suited to further improvements and adaptations: Firstly, the algorithm's fast initial descent speed and high reliability make it a good candidate for being used as part of a global/local search hybrid algorithm. Secondly, it has the potential to be used as part of a hierarchical evolutionary algorithm, which takes advantage of modern multi-core computing architectures. PMID:20196855
Withholding response to self-face is faster than to other-face.
Zhu, Min; Hu, Yinying; Tang, Xiaochen; Luo, Junlong; Gao, Xiangping
2015-01-01
Self-face advantage refers to adults' response to self-face is faster than that to other-face. A stop-signal task was used to explore how self-face advantage interacted with response inhibition. The results showed that reaction times of self-face were faster than that of other-face not in the go task but in the stop response trials. The novelty of the finding was that self-face has shorter stop-signal reaction time compared to other-face in the successful inhibition trials. These results indicated the processing mechanism of self-face may be characterized by a strong response tendency and a corresponding strong inhibition control.
Kraken: ultrafast metagenomic sequence classification using exact alignments
2014-01-01
Kraken is an ultrafast and highly accurate program for assigning taxonomic labels to metagenomic DNA sequences. Previous programs designed for this task have been relatively slow and computationally expensive, forcing researchers to use faster abundance estimation programs, which only classify small subsets of metagenomic data. Using exact alignment of k-mers, Kraken achieves classification accuracy comparable to the fastest BLAST program. In its fastest mode, Kraken classifies 100 base pair reads at a rate of over 4.1 million reads per minute, 909 times faster than Megablast and 11 times faster than the abundance estimation program MetaPhlAn. Kraken is available at http://ccb.jhu.edu/software/kraken/. PMID:24580807
ERIC Educational Resources Information Center
Scriven, Michael
2011-01-01
In this paper, the author talks about Faster Forward Fund (3F). The basic idea of 3F is to provide support for three approaches within the evaluation field that are not the main foci of AEA activities, or of any other organization as far as is known: (1) to develop ideas that show promise for significantly accelerating the theory or practice of…
ERIC Educational Resources Information Center
Forbes, Bethany E.; Skinner, Christopher H.; Maurer, Kristin; Taylor, Emily; Schall, Megan; Cazzell, Samantha; Ciancio, Dennis; Conley, Matt; Conley, Elisha
2015-01-01
Working with middle-school students, we replicated and extended research on oral reading fluency (ORF) assessments and prompting students to read faster. Altering ORF administration procedures by instructing students to read fast caused statistically significant increases in their words correct per minute (WCPM) and errors, which was moderated by…
Neal, Jeremy L.; Lamp, Jane M.; Lowe, Nancy K.; Gillespie, Shannon L.; Sinnott, Loraine T.; Mccarthy, Donna O.
2014-01-01
Objectives To determine if labor-associated inflammatory markers differ between low-risk, nulliparous women in pre-active vs. active labor at hospital admission and over time. Study Design Prospective comparative study of low-risk, nulliparous women with spontaneous labor onset at term (N=118) sampled from two large Midwestern hospitals. Circulating concentrations of inflammatory markers were measured at admission and again 2 and 4 hours later: namely, neutrophil and monocyte counts; and serum inflammatory cytokines (interleukin [IL]-1β, IL-6, tumor necrosis factor [TNF]-α, IL-10) and chemokines (IL-8). Biomarker concentrations and their patterns of change over time were compared between pre-active (n=63) and active (n=55) labor admission groups using Mann-Whitney U tests. Results Concentrations of IL-6 and IL-10 in the active labor admission group were significantly higher than concentrations in the pre-active labor admission group at all three time points. Neutrophil levels were significantly higher in the active group at 2 and 4 hours after admission. The rate of increase in neutrophils and IL-10 between admission and 2 hours later was faster in the active group (p<0.001 and p=0.003, respectively). Conclusions Circulating concentrations of several inflammatory biomarkers are higher and their rate of change over time since admission is faster among low-risk, nulliparous women admitted to hospitals in active labor, as compared to those admitted in pre-active labor. More research is needed to determine if progressive changes in inflammatory biomarkers might be a useful adjunct to improving the assessment of labor progression and determining the optimal timing of labor admission. PMID:25086275
Petersen, Jesper; Sørensen, Henrik; Nielsen, Rasmus Østergaard
2015-04-01
Biomechanical cross-sectional study. To investigate the hypothesis that the cumulative load at the knee during running increases as running speed decreases. The knee joint load per stride decreases as running speed decreases. However, by decreasing running speed, the number of strides per given distance is increased. Running a given distance at a slower speed may increase the cumulative load at the knee joint compared with running the same distance at a higher speed, hence increasing the risk of running-related injuries in the knee. Kinematic and ground reaction force data were collected from 16 recreational runners, during steady-state running with a rearfoot strike pattern at 3 different speeds (mean ± SD): 8.02 ± 0.17 km/h, 11.79 ± 0.21 km/h, and 15.78 ± 0.22 km/h. The cumulative load (cumulative impulse) over a 1000-m distance was calculated at the knee joint on the basis of a standard 3-D inverse-dynamics approach. Based on a 1000-m running distance, the cumulative load at the knee was significantly higher at a slow running speed than at a high running speed (relative difference, 80%). The mean load per stride at the knee increased significantly across all biomechanical parameters, except impulse, following an increase in running speed. Slow-speed running decreases knee joint loads per stride and increases the cumulative load at the knee joint for a given running distance compared to faster running. The primary reason for the increase in cumulative load at slower speeds is an increase in number of strides needed to cover the same distance.
Asencio, Fernanda de Almeida; Ribeiro, Helizabet Abdala Salomão Ayroza; Romeo, Armando; Wattiez, Arnauld; Ribeiro, Paulo Augusto Galvão Ayroza
2018-05-18
To assess whether the monomanual or bimanual training of laparoscopic suture following the same technique may interfere with the knots' performance time and/or quality. A prospective observational study involving 41 resident students of gynecology/obstetrics and general surgery who attended a laparoscopic suture training for 2 days. The participants were divided into two groups. Group A performed the training using exclusively their dominant hand, and group B performed the training using both hands to tie the intracorporeal knot. All participants followed the same technique, called Romeo Gladiator Rule. At the end of the course, the participants were asked to perform three exercises to assess the time it took them to tie the knots, as well as the quality of the knots. A comparative analysis of the groups showed that there was no statistically significant difference ( p = 0.334) between them regarding the length of time to tie one knot. However, when the time to tie 10 consecutive knots was compared, group A was faster than group B ( p = 0.020). A comparison of the knot loosening average, in millimeters, revealed that the knots made by group B loosened less than those made by group A, but there was no statistically significant difference regarding the number of knots that became untied. This study demonstrated that the knots from group B showed better quality than those from group A, with lower loosening measures and more strength necessary to untie the knots. The study also demonstrated that group A was faster than B when the time to tie ten consecutive knots was compared. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.
Honarvar, Mohammad Reza; Eghtesadi, Shahryar; Gill, Pooria; Jazayeri, Shima; Vakili, Mohammad Ali; Shamsardekani, Mohammad Reza; Abbasi, Abdollah
2016-01-01
Background: Acceleration in sputum smear conversion helps faster improvement and decreased probability of the transfer of TB. In this study, we aimed to investigate the effect of green tea extract supplementation on sputum smear conversion and weight changes in smear positive pulmonary TB patients in Iran. Methods: In this double blind clinical study, TB patients were divided into intervention, (n=43) receiving 500 mg green tea extract (GTE), and control groups (n=40) receiving placebo for two months, using balanced randomization. Random allocation and allocation concealment were observed. Height and weight were measured at the beginning, and two and six months post-treatment. Evaluations were performed on three slides, using the ZiehlNeelsen method. Independent and paired t test, McNemar’s, Wilcoxon, Kaplan-Meier, Cox regression model and Log-Rank test were utilized. Statistical significance was set at p<0.05. This trial was registered under IRCT201212232602N11. Results: The interventional changes and the interactive effect of intervention on weight were not significant (p>0.05). In terms of shortening the duration of conversion, the case to control proportion showed a significant difference (p=0.032). Based on the Cox regression model, the hazard ratio of the relative risk of delay in sputum smear conversion was 3.7 (p=0.002) in the higher microbial load group compared to the placebo group and 0.54 (95% CI: 0.31-0.94) in the intervention compared to the placebo group. Conclusion: GTE decreases the risk of delay in sputum smear conversion, but has no effect on weight gain. Moreover, it may be used as an adjuvant therapy for faster rehabilitation for pulmonary TB patients. PMID:27493925
Faghihi, Gita; Iraji, Fariba; Rajaee Harandi, Manijeh; Nilforoushzadeh, Mohammad-Ali; Askari, Gholamreza
2013-01-01
According to the hypothesis on the stimulating effect of adenosine on increasing fibroblast growth factor 7 in dermal papilla cells and its vasorelaxant effect, we performed this study to compare the effect of topical minoxidil 5% and adenosine 0.75% on male pattern androgenetic alopecia. This prospective-randomized study recruited 110 male patients suffering from grade II-V Hamilton androgenetic alopecia. Fifty-five patients received minoxidil 5% (group 1) and adenosine 0.75% (group 2) each. Later, 16 patients were excluded due to allergic reactions or loss to follow up. After 3 and 6 months of treatment, complete and relative recovery rates alongside patient satisfaction rate (faster prevention of primary hair loss and appearance of newly grown hair) were compared between the groups. After 3 months of treatment, relative recovery was achieved in 2.4% and 1.9% of patients in group 1 and group 2, respectively, which was not significantly different (p=0.17). During 6 months, the relative recovery rate did not change either within or between the groups (p=0.99) and after 6 months none of the patients achieved complete recovery. However, the patient satisfaction rate was significantly higher in group 2 (p=0.003). In the light of the results, adenosine has no statistically superiority to minoxidil in the treatment of androgenetic alopecia according to recovery rates. However, the patients were significantly more satisfied with adenosine because of faster prevention of hair loss and appearance of the newly grown hairs. It seems further studies with larger sample size or different drug dosages are required to clarify the findings.
Sakadjian, Alex; Panchuk, Derek; Pearce, Alan J
2014-06-01
This study investigated the effectiveness of action observation (AO) on facilitating learning of the power clean technique (kinematics) compared with traditional strength coaching methods and whether improvements in performance (kinetics) were associated with an improvement in lifting technique. Fifteen subjects (age, 20.9 ± 2.3 years) with no experience in performing the power clean exercise attended 12 training and testing sessions over a 4-week period. Subjects were assigned to 2 matched groups, based on preintervention power clean performance and performed 3 sets of 5 repetitions of the power clean exercise at each training session. Subjects in the traditional coaching group (TC; n = 7) received the standard coaching feedback (verbal cues and physical practice), whereas subjects in the AO group (n = 8) received similar verbal coaching cues and physical practice but also observed a video of a skilled model before performing each set. Kinematic data were collected from video recordings of subjects who were fitted with joint center markings during testing, whereas kinetic data were collected from a weightlifting analyzer attached to the barbell. Subjects were tested before intervention, at the end of weeks 2 and 3, and at after intervention at the end of week 4. Faster improvements (3%) were observed in power clean technique with AO-facilitated learning in the first week and performance improvements (mean peak power of the subject's 15 repetitions) over time were significant (p < 0.001). In addition, performance improvement was significantly associated (R = 0.215) with technique improvements. In conclusion, AO combined with verbal coaching and physical practice of the power clean exercise resulted in significantly faster technique improvements and improvement in performance compared with traditional coaching methods.
Abu Hazeem, Anas A; Gillespie, Matthew J; Thun, Haley; Munson, David; Schwartz, Matthew C; Dori, Yoav; Rome, Jonathan J; Glatz, Andrew C
2013-10-01
To describe our experience with percutaneous closure of patent ductus arteriosus (PDA) in small infants and compare outcomes to matched surgical patients. Ligation via thoracotomy has been used to close PDAs in small infants, but has been associated with respiratory and hemodynamic compromise. We hypothesized that percutaneous closure would offer faster recovery of respiratory function. Patients <4 kg requiring positive pressure ventilation who underwent percutaneous PDA closure between January 2000 and April 2012 were reviewed and matched to contemporary surgical patients on gestational age (GA), birth weight (BW), procedure weight (WT), and ventilation mode. Patients returned to baseline respiratory status when the product of mean airway pressure and FiO2 returned to pre-procedural levels. Eight matched pairs were included. Median BW, GA, and WT were 1.43 kg (0.52-2.97), 29.8 weeks (24-39), and 2.8 kg (2.2-3.9) for catheter patients and 1.55 kg (0.48-3.04), 29 weeks (23-37), and 2.75 kg (2.3-4.2) for surgical patients. Complete PDA closure occurred in all. The median time to return to baseline respiratory status was significantly shorter in the percutaneous group (17 hr (range 0-113) vs. 53 hr (range 13-219), P < 0.05). In the percutaneous group, two patients developed mild aortic coarctation, one mild left pulmonary artery stenosis, and four femoral vascular thromboses which all resolved with medical therapy. Surgical complications included significant respiratory and cardiac compromise, rib fractures and urinary retention. Percutaneous closure of PDA in small infants on respiratory support is equivalent in safety and efficacy and may offer shorter recovery time than surgical ligation. Copyright © 2013 Wiley Periodicals, Inc.
Ten Haaf, Twan; van Staveren, Selma; Iannetta, Danilo; Roelands, Bart; Meeusen, Romain; Piacentini, Maria F; Foster, Carl; Koenderman, Leo; Daanen, Hein A M; de Koning, Jos J
2018-04-01
Reaction time has been proposed as a training monitoring tool, but to date, results are equivocal. Therefore, it was investigated whether reaction time can be used as a monitoring tool to establish overreaching. The study included 30 subjects (11 females and 19 males, age: 40.8 [10.8] years, VO 2max : 51.8 [6.3] mL/kg/min) who participated in an 8-day cycling event. The external exercise load increased approximately 900% compared with the preparation period. Performance was measured before and after the event using a maximal incremental cycling test. Subjects with decreased performance after the event were classified as functionally overreached (FOR) and others as acutely fatigued (AF). A choice reaction time test was performed 2 weeks before (pre), 1 week after (post), and 5 weeks after (follow-up), as well as at the start and end of the event. A total of 14 subjects were classified as AF and 14 as FOR (2 subjects were excluded). During the event, reaction time at the end was 68 ms (95% confidence interval, 46-89) faster than at the start. Reaction time post event was 41 ms (95% confidence interval, 12-71) faster than pre event and follow-up was 55 ms faster (95% confidence interval, 26-83). The time by class interaction was not significant during (P = .26) and after (P = .43) the event. Correlations between physical performance and reaction time were not significant (all Ps > .30). No differences in choice reaction time between AF and FOR subjects were observed. It is suggested that choice reaction time is not valid for early detection of overreaching in the field.
Tastet, Lionel; Capoulade, Romain; Clavel, Marie-Annick; Larose, Éric; Shen, Mylène; Dahou, Abdellaziz; Arsenault, Marie; Mathieu, Patrick; Bédard, Élisabeth; Dumesnil, Jean G.; Tremblay, Alexe; Bossé, Yohan; Després, Jean-Pierre; Pibarot, Philippe
2017-01-01
Aims Hypertension is highly prevalent in patients with aortic stenosis (AS) and is associated with worse outcomes. The current prospective study assessed the impact of systolic hypertension (SHPT) on the progression of aortic valve calcification (AVC) measured by multidetector computed tomography (MDCT) in patients with AS. Methods and results The present analysis includes the first series of 101 patients with AS prospectively recruited in the PROGRESSA study. Patients underwent comprehensive Doppler echocardiography and MDCT exams at baseline and after 2-year follow-up. AVC and coronary artery calcification (CAC) were measured using the Agatston method. Patients with SHPT at baseline (i.e. systolic blood pressure ≥140 mmHg; n = 37, 37%) had faster 2-year AVC progression compared with those without SHPT (i.e. systolic blood pressure <140 mmHg) (AVC median [25th percentile–75th percentile]: +370 [126–824] vs. +157 [58–303] AU; P = 0.007, respectively). Similar results were obtained with the analysis of AVC progression divided by the cross-sectional area of the aortic annulus (AVCdensity: +96 [34–218] vs. +45 [14–82] AU/cm2, P = 0.01, respectively). In multivariable analysis, SHPT remained significantly associated with faster progression of AVC or AVCdensity (all P = 0.001). There was no significant difference between groups with respect to progression of CAC (+39 [3–199] vs. +41 [0–156] AU, P = 0.88). Conclusion This prospective study shows for the first time that SHPT is associated with faster AVC progression but not with CAC progression in AS patients. These findings provide further support for the elaboration of randomized clinical trials to assess the efficacy of antihypertensive medication to slow the stenosis progression in patients with AS. PMID:26896413
Influence of flow velocity on motor behavior of sea cucumber Apostichopus japonicus.
Pan, Yang; Zhang, Libin; Lin, Chenggang; Sun, Jiamin; Kan, Rentao; Yang, Hongsheng
2015-05-15
The influence of flow velocity on the motor behavior of the sea cucumber, Apostichopus japonicus was investigated in the laboratory. Cameras were used to record sea cucumber movements and behavior analysis software was used to measure the distance traveled, time spent, upstream or downstream of the start position and the speed of movements. In general, the mean velocity of A. japonicus was below 0.7mms(-1). The maximum velocity recorded for all the sea cucumbers tested was for a large individual (89.25±17.11g), at a flow rate of 4.6±0.5cms(-1). Medium sized (19.68±5.53g) and large individuals moved significantly faster than small individuals (2.65±1.24g) at the same flow rate. A. japonicus moved significantly faster when there was a moderate current (4.6±0.5cms(-1) and 14.7±0.3cms(-1)), compared with the fast flow rate (29.3±3.7cms(-1)) and when there was no flow (0cms(-1)). Sea cucumbers did not show positive rheotaxis in general, but did move in a downstream direction at faster current speeds. Large, medium and small sized individuals moved downstream at the fastest current speed tested, 29.3±3.7cms(-1). When there was no water flow, sea cucumbers tended to move in an irregular pattern. The movement patterns show that the sea cucumber, A. japonicus can move across the direction of flow, and can move both upstream and downstream along the direction of flow. Copyright © 2015. Published by Elsevier Inc.
Metastable neural dynamics mediates expectation
NASA Astrophysics Data System (ADS)
Mazzucato, Luca; La Camera, Giancarlo; Fontanini, Alfredo
Sensory stimuli are processed faster when their presentation is expected compared to when they come as a surprise. We previously showed that, in multiple single-unit recordings from alert rat gustatory cortex, taste stimuli can be decoded faster from neural activity if preceded by a stimulus-predicting cue. However, the specific computational process mediating this anticipatory neural activity is unknown. Here, we propose a biologically plausible model based on a recurrent network of spiking neurons with clustered architecture. In the absence of stimulation, the model neural activity unfolds through sequences of metastable states, each state being a population vector of firing rates. We modeled taste stimuli and cue (the same for all stimuli) as two inputs targeting subsets of excitatory neurons. As observed in experiment, stimuli evoked specific state sequences, characterized in terms of `coding states', i.e., states occurring significantly more often for a particular stimulus. When stimulus presentation is preceded by a cue, coding states show a faster and more reliable onset, and expected stimuli can be decoded more quickly than unexpected ones. This anticipatory effect is unrelated to changes of firing rates in stimulus-selective neurons and is absent in homogeneous balanced networks, suggesting that a clustered organization is necessary to mediate the expectation of relevant events. Our results demonstrate a novel mechanism for speeding up sensory coding in cortical circuits. NIDCD K25-DC013557 (LM); NIDCD R01-DC010389 (AF); NSF IIS-1161852 (GL).
Faster REM sleep EEG and worse restedness in older insomniacs with HLA DQB1*0602
Zeitzer, Jamie Marc; Fisicaro, Ryan Anthony; Grove, Megan Elizabeth; Mignot, Emmanuel; Yesavage, Jerome Albert; Friedman, Leah
2011-01-01
HLA DQB1*0602 is found in most individuals with hypocretin-deficient narcolepsy, a disorder characterized by a severe disruption of sleep and wake. Population studies indicate that DQB1*0602 may also be associated with normal phenotypic variation of rapid eye movement (REM) sleep. Disruption of REM sleep has been linked to specific symptoms of insomnia. We here examine the relationship of sleep and DQB1*0602 in older individuals (n=46) with primary insomnia, using objective (polysomnography, wrist actigraphy) and subjective (logs, scales) measures. DQB1*0602 positivity was similarly distributed in the older individuals with insomnia (24%) as in the general population (25%). Most sleep variables were statistically indistinguishable between DQB1*0602 positive and negative subjects except that those with the allele reported that they were significantly less well rested than those without it. When sleep efficiencies were lower than 70%, DQB1*0602 positive subjects reported being less well rested at the same sleep efficiency than those without the allele. Examination of EEG during REM sleep also revealed that DQB1*0602 positive subjects had EEG shifted towards faster frequencies compared with negative subjects. Thus, DQB1*0602 positivity is associated with both a shift in EEG power spectrum to faster frequencies during REM sleep and a diminution of restedness given the same sleep quantity. PMID:21292329
Hammel, Naama; Belghith, Akram; Weinreb, Robert N; Medeiros, Felipe A; Mendoza, Nadia; Zangwill, Linda M
2017-06-01
To compare the rates of circumpapillary retinal nerve fiber layer (RNFL) and macular retinal ganglion cell-inner plexiform layer (GCIPL) change over time in healthy and glaucoma eyes. Cohort study. The rates of circumpapillary RNFL and macular GCIPL loss in 28 healthy subjects and 97 glaucoma subjects from the Diagnostic Innovations in Glaucoma Study (DIGS) were compared using mixed-effects models. The median follow-up time and number of visits were 1.7 years and 6 visits and 3.2 years and 7 visits for healthy and glaucoma eyes, respectively. Significant rates of loss of both global circumpapillary RNFL and average macular GCIPL thickness were detectable in early and moderate glaucoma eyes; in severe glaucoma eyes, rates of average macular GCIPL loss were significant, but rates of global circumpapillary RNFL loss were not. In glaucoma eyes, mean rates of global circumpapillary RNFL thickness change (-0.98 μm/year [95% confidence interval (CI), -1.20 to -0.76]) and normalized global circumpapillary RNFL change (-1.7%/year [95% CI, -2.1 to -1.3]) were significantly faster than average macular GCIPL change (-0.57 μm/year [(95% CI, -0.73 to -0.41]) and normalized macular GCIPL change (-1.3%/year [95% CI, -1.7 to -0.9]). The rates of global and inferior RNFL change were weakly correlated with global and inferior macular GCIPL change (r ranges from 0.16 to 0.23, all P < .05). In this cohort, the rate of circumpapillary RNFL thickness change was faster than macular GCIPL change for glaucoma eyes. Global circumpapillary RNFL thickness loss was detectable in early and moderate glaucoma, and average macular GCIPL thickness loss was detectable in early, moderate, and severe glaucoma, suggesting that structural changes can be detected in severe glaucoma. Copyright © 2017 Elsevier Inc. All rights reserved.
Choosing the Most Effective Pattern Classification Model under Learning-Time Constraint.
Saito, Priscila T M; Nakamura, Rodrigo Y M; Amorim, Willian P; Papa, João P; de Rezende, Pedro J; Falcão, Alexandre X
2015-01-01
Nowadays, large datasets are common and demand faster and more effective pattern analysis techniques. However, methodologies to compare classifiers usually do not take into account the learning-time constraints required by applications. This work presents a methodology to compare classifiers with respect to their ability to learn from classification errors on a large learning set, within a given time limit. Faster techniques may acquire more training samples, but only when they are more effective will they achieve higher performance on unseen testing sets. We demonstrate this result using several techniques, multiple datasets, and typical learning-time limits required by applications.
Taylor, Daniel; Smith, Mark F.
2017-01-01
Purpose: To examine the effects of deceptively aggressive bike pacing on performance, pacing, and associated physiological and perceptual responses during simulated sprint-distance triathlon. Methods: Ten non-elite, competitive male triathletes completed three simulated sprint-distance triathlons (0.75 km swim, 500 kJ bike, 5 km run), the first of which established personal best “baseline” performance (BL). During the remaining two trials athletes maintained a cycling power output 5% greater than BL, before completing the run as quickly as possible. However, participants were informed of this aggressive cycling strategy before and during only one of the two trials (HON). Prior to the alternate trial (DEC), participants were misinformed that cycling power output would equal that of BL, with on-screen feedback manipulated to reinforce this deception. Results: Compared to BL, a significantly faster run performance was observed following DEC cycling (p < 0.05) but not following HON cycling (1348 ± 140 vs. 1333 ± 129 s and 1350 ± 135 s, for BL, DEC, and HON, respectively). As such, magnitude-based inferences suggest HON running was more likely to be slower, than faster, compared to BL, and that DEC running was probably faster than both BL and HON. Despite a trend for overall triathlon performance to be quicker during DEC (4339 ± 395 s) compared to HON (4356 ± 384 s), the only significant and almost certainly meaningful differences were between each of these trials and BL (4465 ± 420 s; p < 0.05). Generally, physiological and perceptual strain increased with higher cycling intensities, with little, if any, substantial difference in physiological and perceptual response during each triathlon run. Conclusions: The present study is the first to show that mid-event pace deception can have a practically meaningful effect on multi-modal endurance performance, though the relative importance of different psychophysiological and emotional responses remains unclear. Whilst our findings support the view that some form of anticipatory “template” may be used by athletes to interpret levels of psychophysiological and emotional strain, and regulate exercise intensity accordingly, they would also suggest that individual constructs such as RPE and affect may be more loosely tied with pacing than previously suggested. PMID:28174540
[Laser biostimulation in the treatment of pleurisy].
Milojević, Momir; Kuruc, Vesna
2003-01-01
Low-intensity lasers have been utilized in medicine in two ways: for local stimulation and for stimulation of acupuncture points. Literature data reveal that this method has been indiscriminately applied in psychiatry, rheumatology, gynecology, dermatology, otorhinolaryngology, in diverse acute and chronic pains, inflammations, vascular disorders, angina pectoris, bronchial asthma. Most commonly reported clinical effects are analgesia, spasmolytic and anti-inflammatory effects, as well as faster wound and bone healing. This prospective study analyses effects of laser biostimulation on patients with pleurisy. The analysis included 25 patients treated at the Institute of Lung Diseases in Sremska Kamenica during 2000, 2001 and 2002. Apart from conservative treatment, these patients were treated with laser biostimulation of acupuncture points and local region for ten days. During treatment, changes of present clinical signs, general symptoms, radiological findings, as well as changes of some relevant biochemical parameters were recorded. Results were compared with the control group which included the same number of patients, who differed from the examined group only by not being exposed to laser biostimulation. The examined group of patients with pleuritis presented with quicker resorption of pleural effusion, less pleural adhesions, more significant decrease of clinical symptoms, especially pain, as well as more significant increase of cortisol and immunoglobulin A and decrease of circulating immune complexes (CIC), leukocytes and sedimentation rate than the control group. Mechanisms of laser biostimulation in treatment of pleurisy were described in detail and the obtained results were correlated to those reported by other authors. 1. Patients with pleurisy undergoing laser stimulation presented with faster resorption of effusion and remission of the subjective symptoms, as well as significant decrease of biochemical acute inflammation parameters in the peripheral blood and therefore with faster recovery. 2. In patients with pleurisy laser treatment increases regenerative mechanisms of the pleural surface, thus decreasing the quantity of formed adhesions and resulting in better mobility of the diaphragm.
Giri, Sidhartha; Rajan, Anand K; Kumar, Nirmal; Dhanapal, Pavithra; Venkatesan, Jayalakshmi; Iturriza-Gomara, Miren; Taniuchi, Mami; John, Jacob; Abraham, Asha Mary; Kang, Gagandeep
2017-08-01
Although, culture is considered the gold standard for poliovirus detection from stool samples, real-time PCR has emerged as a faster and more sensitive alternative. Detection of poliovirus from the stool of recently vaccinated children by culture, single and multiplex real-time PCR was compared. Of the 80 samples tested, 55 (68.75%) were positive by culture compared to 61 (76.25%) and 60 (75%) samples by the single and one step multiplex real-time PCR assays respectively. Real-time PCR (singleplex and multiplex) is more sensitive than culture for poliovirus detection in stool, although the difference was not statistically significant. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Yang, Liqin; Sang, Nong; Gao, Changxin
2018-03-01
Vehicle parts detection plays an important role in public transportation safety and mobility. The detection of vehicle parts is to detect the position of each vehicle part. We propose a new approach by combining Faster RCNN and three level cascaded convolutional neural network (DCNN). The output of Faster RCNN is a series of bounding boxes with coordinate information, from which we can locate vehicle parts. DCNN can precisely predict feature point position, which is the center of vehicle part. We design an output strategy by combining these two results. There are two advantages for this. The quality of the bounding boxes are greatly improved, which means vehicle parts feature point position can be located more precise. Meanwhile we preserve the position relationship between vehicle parts and effectively improve the validity and reliability of the result. By using our algorithm, the performance of the vehicle parts detection improve obviously compared with Faster RCNN.
A comparison of two central difference schemes for solving the Navier-Stokes equations
NASA Technical Reports Server (NTRS)
Maksymiuk, C. M.; Swanson, R. C.; Pulliam, T. H.
1990-01-01
Five viscous transonic airfoil cases were computed by two significantly different computational fluid dynamics codes: An explicit finite-volume algorithm with multigrid, and an implicit finite-difference approximate-factorization method with Eigenvector diagonalization. Both methods are described in detail, and their performance on the test cases is compared. The codes utilized the same grids, turbulence model, and computer to provide the truest test of the algorithms. The two approaches produce very similar results, which, for attached flows, also agree well with experimental results; however, the explicit code is considerably faster.
Phonological priming in young children who stutter: holistic versus incremental processing.
Byrd, Courtney T; Conture, Edward G; Ohde, Ralph N
2007-02-01
To investigate the holistic versus incremental phonological encoding processes of young children who stutter (CWS; N = 26) and age- and gender-matched children who do not stutter (CWNS; N = 26) via a picture-naming auditory priming paradigm. Children named pictures during 3 auditory priming conditions: neutral, holistic, and incremental. Speech reaction time (SRT) was measured from the onset of picture presentation to the onset of participant response. CWNS shifted from being significantly faster in the holistic priming condition to being significantly faster in the incremental priming condition from 3 to 5 years of age. In contrast, the majority of 3- and 5-year-old CWS continued to exhibit faster SRT in the holistic than the incremental condition. CWS are delayed in making the developmental shift in phonological encoding from holistic to incremental processing, a delay that may contribute to their difficulties establishing fluent speech.
How gender and task difficulty affect a sport-protective response in young adults
Lipps, David B.; Eckner, James T.; Richardson, James K.; Ashton-Miller, James A.
2013-01-01
We tested the hypotheses that gender and task difficulty affect the reaction, movement, and total response times associated with performing a head protective response. Twenty-four healthy young adults (13 females) performed a protective response of raising their hands from waist level to block a foam ball fired at their head from an air cannon. Participants initially stood 8.25 m away from the cannon (‘low difficulty’), and were moved successively closer in 60 cm increments until they failed to block at least 5 of 8 balls (‘high difficulty’). Limb motion was quantified using optoelectronic markers on the participants’ left wrist. Males had significantly faster total response times (p = 0.042), a trend towards faster movement times (p = 0.054), and faster peak wrist velocity (p < .001) and acceleration (p = 0.032) than females. Reaction time, movement time, and total response time were significantly faster under high difficulty conditions for both genders (p < .001). This study suggests that baseball and softball pitchers and fielders should have sufficient time to protect their head from a batted ball under optimal conditions if they are adequately prepared for the task. PMID:23234296
Fast Laplace solver approach to pore-scale permeability
NASA Astrophysics Data System (ADS)
Arns, C. H.; Adler, P. M.
2018-02-01
We introduce a powerful and easily implemented method to calculate the permeability of porous media at the pore scale using an approximation based on the Poiseulle equation to calculate permeability to fluid flow with a Laplace solver. The method consists of calculating the Euclidean distance map of the fluid phase to assign local conductivities and lends itself naturally to the treatment of multiscale problems. We compare with analytical solutions as well as experimental measurements and lattice Boltzmann calculations of permeability for Fontainebleau sandstone. The solver is significantly more stable than the lattice Boltzmann approach, uses less memory, and is significantly faster. Permeabilities are in excellent agreement over a wide range of porosities.
Comparison of VMAT and IMRT strategies for cervical cancer patients using automated planning.
Sharfo, Abdul Wahab M; Voet, Peter W J; Breedveld, Sebastiaan; Mens, Jan Willem M; Hoogeman, Mischa S; Heijmen, Ben J M
2015-03-01
In a published study on cervical cancer, 5-beam IMRT was inferior to single arc VMAT. Here we compare 9, 12, and 20 beam IMRT with single and dual arc VMAT. For each of 10 patients, automated plan generation with the in-house Erasmus-iCycle optimizer was used to assist an expert planner in generating the five plans with the clinical TPS. For each patient, all plans were clinically acceptable with a high and similar PTV coverage. OAR sparing increased when going from 9 to 12 to 20 IMRT beams, and from single to dual arc VMAT. For all patients, 12 and 20 beam IMRT were superior to single and dual arc VMAT, with substantial variations in gain among the study patients. As expected, delivery of VMAT plans was significantly faster than delivery of IMRT plans. Often reported increased plan quality for VMAT compared to IMRT has not been observed for cervical cancer. Twenty and 12 beam IMRT plans had a higher quality than single and dual arc VMAT. For individual patients, the optimal delivery technique depends on a complex trade-off between plan quality and treatment time that may change with introduction of faster delivery systems. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
High-intensity interval training has positive effects on performance in ice hockey players.
Naimo, M A; de Souza, E O; Wilson, J M; Carpenter, A L; Gilchrist, P; Lowery, R P; Averbuch, B; White, T M; Joy, J
2015-01-01
In spite of the well-known benefits that have been shown, few studies have looked at the practical applications of high-intensity interval training (HIIT) on athletic performance. This study investigated the effects of a HIIT program compared to traditional continuous endurance exercise training. 24 hockey players were randomly assigned to either a continuous or high-intensity interval group during a 4-week training program. The interval group (IG) was involved in a periodized HIIT program. The continuous group (CG) performed moderate intensity cycling for 45-60 min at an intensity that was 65% of their calculated heart rate reserve. Body composition, muscle thickness, anaerobic power, and on-ice measures were assessed pre- and post-training. Muscle thickness was significantly greater in IG (p=0.01) when compared to CG. The IG had greater values for both ∆ peak power (p<0.003) and ∆ mean power (p<0.02). Additionally, IG demonstrated a faster ∆ sprint (p<0.02) and a trend (p=0.08) for faster ∆ endurance test time to completion for IG. These results indicate that hockey players may utilize short-term HIIT to elicit positive effects in muscle thickness, power and on-ice performance. © Georg Thieme Verlag KG Stuttgart · New York.
Growth pattern and age at menarche of obese girls in a transitional society.
Jaruratanasirikul, S; Mo-suwan, L; Lebel, L
1997-01-01
Childhood obesity is an increasing problem in a transitional society such as Thailand. To study physical growth and puberty in obese children, a cross-sectional survey of growth and age at menarche was carried out in schoolgirls aged between 8 and 16 years old. The 3,120 girls were divided into two groups based on weight-for-height criteria. Girls with weight-for-height between 80 and 120% were classified as normal stature (2,625; 84.1%) and those more than 120% were obese (495; 15.9%). Using probit analysis, age at menarche in obese girls was 0.9 year earlier than normal stature girls (11.5 years vs 12.4 years). At age 12, obese girls were reaching menarche 2.8 times more when compared with the normal stature girls. In terms of growth pattern, obese girls were taller and grew faster during the prepubertal period, and then reached their final height earlier than the normal stature girls (13 years vs 15 years). The final height in obese girls was significantly shorter (153.0 cm and 155.0 cm, p = 0.01). We conclude that: 1) obese girls grow faster, have earlier menarche and then stop growing earlier, and 2) obese girls tend to be shorter as adults, compared with normal stature girls.
Effect of gender on fatigue and recovery following maximal intensity repeated sprint performance.
Laurent, C M; Green, J M; Bishop, P A; Sjökvist, J; Schumacker, R E; Richardson, M T; Curtner-Smith, M
2010-09-01
This study investigated the effects of gender on repeated, maximal-intensity intermittent sprint exercise following variable day-to-day recovery periods. Sixteen volunteers (8 men, 8 women) performed four trials of high-intensity intermittent sprint exercise consisting of three bouts of eight 30 m sprints (total of 24 sprints). Following completion of the baseline trial, in repeated-measures design, participants were assigned, in counter-balanced order, variable recovery periods of 24, 48, and 72 h whereupon they repeated an identical exercise trial. Results from a series of 4 (trial) x 3 (bout) repeated measures ANOVAs revealed men produced significantly (P < 0.01) faster times throughout all bouts and trials of repeated sprint exercise. Additionally, women exhibited significantly lower (P < 0.05) blood lactate concentration and significantly lower (P < 0.05) decrement in performance, indicating increased resistance to fatigue during repeated exercise sessions. There were no significant differences (P > 0.05) between genders for heart rate or rating of perceived exertion during or following trials. There were no significant differences for overall sprint performance within either gender among trials. These results indicate men, while able to produce higher absolute power outputs (i.e., lower sprint time), demonstrate higher decrement scores within a trial compared to women, thus suggesting women may recover faster and fatigue less. Also, gender differences affecting recovery within in a trial were observed to be diminished between trials (i.e., day-to-day recovery) of maximal intermittent sprint work evidenced by the observed stability of performance between trials following various recovery durations.
ERIC Educational Resources Information Center
Marcotullio, Peter J.
2006-01-01
Researchers have identified how in some rapidly developing countries, road and aviation transportation CO2 emissions are rising faster (over time) when compared to the experiences of the USA at similar levels of economic development. While suggestive of how experiences of the rapidly developing Asia are different from those of the developed world…
Cardiovascular fitness in obese versus nonobese 8-11-year-old boys and girls.
Mastrangelo, M Alysia; Chaloupka, Edward C; Rattigan, Peter
2008-09-01
The purpose of this study was to compare cardiovascular fitness between obese and nonobese children. Based on body mass index, 118 were classified as obese (boys [OB] = 62, girls [OG] = 56), while 421 were nonobese (boys [NOB] = 196, girls [NOG] = 225). Cardiovascular fitness was determined by a 1-mile [1.6 km] run/walk (MRW) and estimated peak oxygen uptake (VO2peak) and analyzed using two-way analyses of variance (Gender x Obese/Nonobese). MRW times were significantly faster (p < .05) for the NOB (10 min 34 s) compared to the OB (13 min 8 s) and the NOG (13 min 15 s.) compared to the OG (14 min 44 s.). Predicted VO2peak values (mL x kg(-1) x min(-1)) were significantly higher (p < .05) for the NOB (48.29) compared to the OB (41.56) and the NOG (45.99) compared to the OG (42.13). MRW was compared between obese and nonobese participants on the President's Challenge (2005), the National Children and Youth Fitness Study, and FITNESSGRAM HFZ standards. The nonobese boys and girls scored higher on all three, exhibiting better cardiovascular fitness as compared to obese counterparts.
Levrini, G; Sghedoni, R; Mori, C; Botti, A; Vacondio, R; Nitrosi, A; Iori, M; Nicoli, F
2011-10-01
The aim of this study was to investigate the efficacy of a dedicated software tool for automated volume measurement of breast lesions in contrast-enhanced (CE) magnetic resonance mammography (MRM). The size of 52 breast lesions with a known histopathological diagnosis (three benign, 49 malignant) was automatically evaluated using different techniques. The volume of all lesions was measured automatically (AVM) from CE 3D MRM examinations by means of a computer-aided detection (CAD) system and compared with the size estimates based on maximum diameter measurement (MDM) on MRM, ultrasonography (US), mammography and histopathology. Compared with histopathology as the reference method, AVM understimated lesion size by 4% on average. This result was similar to MDM (3% understimation, not significantly different) but significantly better than US and mammographic lesion measurements (24% and 33% size underestimation, respectively). AVM is as accurate as MDM but faster. Both methods are more accurate for size assessment of breast lesions compared with US and mammography.
El-Gazayerly, O N; Makhlouf, A I A; Soelm, A M A; Mohmoud, M A
2014-01-01
Milk thistle extract is a well-known hepatoprotectant with low bioavailability (20-50%). The objective of the present study is to prepare and characterize silymarin phytosomes and to test the hepatoprotective effect of the phytosomes in CCl4 induced liver injury in rats compared to milk thistle extract. Phytosomes were prepared using lecithin from soybeans and from egg yolk. The prepared phytosomes were examined using scanning electron microscopy, transmission electron microscopy, differential scanning calorimetry, Fourier transform infrared spectroscopy and proton nuclear magnetic resonance spectroscopy (H(1)NMR). The loading efficiency was >85% in all phytosomal formulations. Formula P2 (with the molar ratio of soybean lecithin to silybin 1:1) and P4 (with the molar ratio of egg-yolk lecithin to silybin 0.25:1) exhibited significantly (p < 0.05) faster release than milk thistle extract. The in vivo study revealed that phytosomes significantly (p < 0.05) decreased glutamic pyruvic transaminase and super oxide dismutase activities compared to milk thistle extract.
In vitro studies of degradation and bioactivity of aliphatic polyester composites
NASA Astrophysics Data System (ADS)
Chouzouri, Georgia
In spite of numerous publications on the potential use of combinations of aliphatic polyester composites containing bioactive fillers for bone regeneration, little information exists on the combined in vitro mechanisms involving simultaneously diffusion for polymer degradation and bioactivity through nucleation and growth of apatite in simulated body fluid (SBF) solution. The objective of this study is to contribute to the understanding of the fundamentals in designing non-porous, solid materials for bone regeneration, from experimental data along with their engineering interpretation. Bioactivity, in terms of apatite growth, was assessed through several experimental methods such as scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDX), X-ray-diffraction (XRD) and changes in ion concentration. In the case of the six neat fillers evaluated, the filler shape, form and chemical structure showed significant differences in bioactivity response. Bioglass and calcium silicate fillers showed faster nucleation and growth rates in the screening experiments. Composites at 30% by weight filler were prepared by solution and/or melt mixing. Polycaprolactone (PCL) composites containing five different fillers were evaluated. Solution processed PCL/calcium silicate (CS) samples showed faster bioactivity, as determined by apatite growth, compared to melt mixed samples. The onset time for bioactivity was different for all PCL composites. The limited bioactivity in the PCL composites over longer periods of time could be attributed to the PCL hydrophobicity leading to a slow polymer degradation rate, and also to the lack of SBF replenishment. For both polylactic acid (PLA) composites containing CS and bioglass, significant growth was observed after one week and in the case of CS was still evident after four weeks immersion. However, at prolonged time periods no further bioactivity was observed, although ion release results indicated a faster release rate that would eventually lead to a faster polymer degradation and possibly continuing bioactivity. The presence of silicate fillers enhanced the hydrolytic degradation rate of both PCL and PLA as shown from kinetic data calculations based on molecular weight measurements. Unfilled PLA samples showed significant embrittlement after two weeks immersion, whereas for the CS filled system more significant changes could be observed in the compressive strength and modulus after the same time period. Experimental data were also fitted into an equation proposed to calculate erosion number; in the case of unfilled PLA predictions were found to agree with literature results suggesting bulk erosion. By assuming impermeable, randomly dispersed glass flakes, water transport in a composite system, prior to significant polymer degradation could be modeled. However, modeling of transport in the case of the composite consisting of a degrading polymer and a reactive decaying filler was challenging, particularly in the case of directional bioactive reinforcements, due to the occurrence of simultaneous time dependent diffusion phenomena that altered the integrity of the sample.
Seebacher, F; Franklin, C E
2001-12-01
During thermoregulation in the bearded dragon Pogona barbata, heart rate when heating is significantly faster than when cooling at any given body temperature (heart rate hysteresis), resulting in faster rates of heating than cooling. However, the mechanisms that control heart rate during heating and cooling are unknown. The aim of this study was to test the hypothesis that changes in cholinergic and adrenergic tone on the heart are responsible for the heart rate hysteresis during heating and cooling in P. barbata. Heating and cooling trials were conducted before and after the administration of atropine, a muscarinic antagonist, and sotalol, a beta-adrenergic antagonist. Cholinergic and beta-adrenergic blockade did not abolish the heart rate hysteresis, as the heart rate during heating was significantly faster than during cooling in all cases. Adrenergic tone was extremely high (92.3 %) at the commencement of heating, and decreased to 30.7 % at the end of the cooling period. Moreover, in four lizards there was an instantaneous drop in heart rate (up to 15 beats min(-1)) as the heat source was switched off, and this drop in heart rate coincided with either a drop in beta-adrenergic tone or an increase in cholinergic tone. Rates of heating were significantly faster during the cholinergic blockade, and least with a combined cholinergic and beta-adrenergic blockade. The results showed that cholinergic and beta-adrenergic systems are not the only control mechanisms acting on the heart during heating and cooling, but they do have a significant effect on heart rate and on rates of heating and cooling.
Maloney, Sean J; Turner, Anthony N; Miller, Stuart
2014-10-01
It has previously been shown that a loaded warm-up may improve power performances. We examined the acute effects of loaded dynamic warm-up on change of direction speed (CODS), which had not been previously investigated. Eight elite badminton players participated in three sessions during which they performed vertical countermovement jump and CODS tests before and after undertaking the dynamic warm-up. The three warm-up conditions involved wearing a weighted vest (a) equivalent to 5% body mass, (b) equivalent to 10% body mass, and (c) a control where a weighted vest was not worn. Vertical jump and CODS performances were then tested at 15 seconds and 2, 4, and 6 minutes post warm-up. Vertical jump and CODS significantly improved following all warm-up conditions (P < .05). Post warm-up vertical jump performance was not different between conditions (P = .430). Post warm-up CODS was significantly faster following the 5% (P = .02) and 10% (P < .001) loaded conditions compared with the control condition. In addition, peak CODS test performances, independent of recovery time, were faster than the control condition following the 10% loaded condition (P = .012). In conclusion, the current study demonstrates that a loaded warm-up augmented CODS, but not vertical jump performance, in elite badminton players.
Physical characteristics of indigestible solids affect emptying from the fasting human stomach.
Meyer, B; Beglinger, C; Neumayer, M; Stalder, G A
1989-01-01
Gastric emptying of indigestible solids depends on their size. It is not clear whether physical characteristics other than particle size affect emptying of indigestible solids from the fasting human stomach. We studied gastric emptying of three differently shaped particles, (cubes, spheres, rods) of either hard or soft consistency during the fasting state in human volunteers. The shape of indigestible particles did not affect their emptying. The area under the gastric emptying curve (AUC: particles x hour) was for hard cubes 24.7 (2.2), for hard spheres 27.9 (1.6), for hard rods 26.9 (2.7). All soft particles emptied faster than their identically shaped hard counterparts, but there was no difference among the three shapes (AUC for soft cubes: 29.2 (3.0), for soft spheres 32.0 (1.8), for soft rods 34.1 (1.2). If gastric emptying of hard and soft particles was compared independently of their shape, soft particles emptied significantly faster than hard ones: AUC 31.8 (1.2) v 26.5 (1.3) (p less than 0.01). In conclusion, the consistency but not the shape significantly affects gastric emptying. Specific physical characteristics other than size and shape may affect gastric emptying of indigestible particles which may be of importance in the design of drugs. PMID:2599438
The impact of endocrine supplementation on adverse events in septic shock.
Bissell, Brittany D; Erdman, Michael J; Smotherman, Carmen; Kraemer, Dale F; Ferreira, Jason A
2015-12-01
The objective of this study was to compare the incidence of severe adverse events of vasopressin vs hydrocortisone for endocrine support therapy in patients with septic shock. This was a retrospective, propensity-matched cohort of patients admitted to the medical intensive care unit with septic shock between February 2012 and February 2015. Patients were included if vasopressin or hydrocortisone was administered for hemodynamic support secondary to norepinephrine. In the unmatched cohort of 124 patients, vasopressin was associated with a significant decrease in the number of severe adverse events (P=.03). In the matched cohort, severe adverse events occurred 3 times as often in patients receiving hydrocortisone; however, this difference was not statistically significant. (odds ratio, 3.33; 95% confidence interval, 0.92-12.11; P=.06). In the matched cohort, vasopressin was associated with a faster time to hemodynamic stability (P<.05) and discontinuation of hemodynamic support (P<.01) with an increased requirement for third-line therapy (P<.01). No statistical differences were seen in length of stay (intensive care unit and hospital), length of mechanical ventilation, and in-hospital mortality. Given the lower incidence of adverse events and faster time to hemodynamic stability, vasopressin appears to be the most advantageous endocrine agent for hemodynamic support in septic shock. Copyright © 2015 Elsevier Inc. All rights reserved.
Laterality of repetitive finger movement performance and clinical features of Parkinson's disease.
Stegemöller, Elizabeth; Zaman, Andrew; MacKinnon, Colum D; Tillman, Mark D; Hass, Chris J; Okun, Michael S
2016-10-01
Impairments in acoustically cued repetitive finger movement often emerge at rates near to and above 2Hz in persons with Parkinson's Disease (PD) in which some patients move faster (hastening) and others move slower (bradykinetic). The clinical features impacting this differential performance of repetitive finger movement remain unknown. The purpose of this study was to compare repetitive finger movement performance between the more and less affected side, and the difference in clinical ratings among performance groups. Forty-one participants diagnosed with idiopathic PD completed an acoustically cued repetitive finger movement task while "on" medication. Eighteen participants moved faster, 10 moved slower, and 13 were able to maintain the appropriate rate at rates above 2Hz. Clinical measures of laterality, disease severity, and the UPDRS were obtained. There were no significant differences between the more and less affected sides regardless of performance group. Comparison of disease severity, tremor, and rigidity among performance groups revealed no significant differences. Comparison of posture and postural instability scores revealed that the participants that demonstrated hastening had worse posture and postural instability scores. Consideration of movement rate during the clinical evaluation of repetitive finger movement may provide additional insight into varying disease features in persons with PD. Copyright © 2016 Elsevier B.V. All rights reserved.
Analysis of proximal and distal muscle activity during handwriting tasks.
Naider-Steinhart, Shoshana; Katz-Leurer, Michal
2007-01-01
In this study we sought to describe upper-extremity proximal and distal muscle activity in typically developing children during a handwriting task and to explore the relationship between muscle activity and speed and quality of writing. We evaluated 35 third- and fourth-grade Israeli children using the Alef-Alef Ktav Yad Hebrew Handwriting Test. Simultaneously, we recorded the participants' upper trapezius and thumb muscle activity by surface electromyography. Using the coefficient of variation (standard deviation divided by mean amplitude) as a measure of variability within each muscle, we analyzed differences in muscle activity variability within and between muscles. The proximal muscle displayed significantly less variability than the distal muscles. Decreased variability in proximal muscle activity was associated with decreased variability in distal muscle activity, and decreased variability in the distal muscles was significantly associated with faster speed of writing. The lower amount of variability exhibited in the proximal muscle compared with the distal muscles seems to indicate that the proximal muscle functions as a stabilizer during a handwriting task. In addition, decreased variability in both proximal and distal muscle activity appears to be more economical and is related to faster writing speed. Knowledge of the type of proximal and distal muscle activity used during handwriting can help occupational therapists plan treatment for children with handwriting disabilities.
Black, Emily; Stevenson, Jennifer L; Bish, Joel P
2017-08-01
The global precedence effect is a phenomenon in which global aspects of visual and auditory stimuli are processed before local aspects. Individuals with musical experience perform better on all aspects of auditory tasks compared with individuals with less musical experience. The hemispheric lateralization of this auditory processing is less well-defined. The present study aimed to replicate the global precedence effect with auditory stimuli and to explore the lateralization of global and local auditory processing in individuals with differing levels of musical experience. A total of 38 college students completed an auditory-directed attention task while electroencephalography was recorded. Individuals with low musical experience responded significantly faster and more accurately in global trials than in local trials regardless of condition, and significantly faster and more accurately when pitches traveled in the same direction (compatible condition) than when pitches traveled in two different directions (incompatible condition) consistent with a global precedence effect. In contrast, individuals with high musical experience showed less of a global precedence effect with regards to accuracy, but not in terms of reaction time, suggesting an increased ability to overcome global bias. Further, a difference in P300 latency between hemispheres was observed. These findings provide a preliminary neurological framework for auditory processing of individuals with differing degrees of musical experience.
Elbin, R J; Beatty, Amanda; Covassin, Tracey; Schatz, Philip; Hydeman, Ana; Kontos, Anthony P
2015-01-01
This study compared changes in neurocognitive performance and symptom reports following an acute bout of soccer heading among athletes with and without protective soccer headgear. A total of 25 participants headed a soccer ball 15 times over a 15-minute period, using a proper linear heading technique. Participants in the experimental group completed the heading exercise while wearing a protective soccer headband and controls performed the heading exercise without wearing the soccer headband. Neurocognitive performance and symptom reports were assessed before and after the acute bout of heading. Participants wearing the headband showed significant decreases on verbal memory (p = 0.02) compared with the no headband group, while the no headband group demonstrated significantly faster reaction time (p = 0.03) than the headband group following the heading exercise. These findings suggest that protective soccer headgear likely does not mitigate the subtle neurocognitive effects of acute soccer heading.
NASA Technical Reports Server (NTRS)
Hopkins, W. D.; Washburn, D. A.; Hyatt, C. W.; Rumbaugh, D. M. (Principal Investigator)
1996-01-01
This study describes video-task acquisition in two nonhuman primate species. The subjects were seven rhesus monkeys (Macaca mulatta) and seven chimpanzees (Pan troglodytes). All subjects were trained to manipulate a joystick which controlled a cursor displayed on a computer monitor. Two criterion levels were used: one based on conceptual knowledge of the task and one based on motor performance. Chimpanzees and rhesus monkeys attained criterion in a comparable number of trials using a conceptually based criterion. However, using a criterion based on motor performance, chimpanzees reached criterion significantly faster than rhesus monkeys. Analysis of error patterns and latency indicated that the rhesus monkeys had a larger asymmetry in response bias and were significantly slower in responding than the chimpanzees. The results are discussed in terms of the relation between object manipulation skills and video-task acquisition.
Mohammadi, Roghayeh; Ershad, Navid; Rezayinejad, Marziyeh; Fatemi, Elham; Phadke, Chetan P
2017-09-01
To examine the functional effects of walking retraining at faster than self-selected speed (SSS). Ten individuals with chronic stroke participated in a 4-week training over a treadmill at walking speeds 40% faster than SSS, three times per week, 30 min/session. Outcome measures assessed before, after, and 2 months after the end of intervention were the Timed Up and Go, the 6-Minute Walk, the 10-Meter Walk test, the Modified Ashworth Scale, SSS, and fastest comfortable speed. After 4 weeks of training, all outcome measures showed clinically meaningful and statistically significant improvements (P<0.05) that were maintained at 2 months after the end of the training. The results showed that a strategy of training at a speed 40% faster than SSS can improve functional activity in individuals with chronic stroke, with effects lasting up to 2 months after the intervention.
Aggarwal, Sunny; Upadhyay, Amit; Shah, Dheeraj; Teotia, Neeraj; Agarwal, Astha; Jaiswal, Vijay
2014-01-01
Background & objectives: Randomized controlled trials in developed countries have reported benefits of Lactobacillus GG (LGG) in the treatment of acute watery diarrhoea, but there is paucity of such data from India. The study was aimed to evaluate the efficacy and safety of Lactobacillus GG in the treatment of acute diarrhoea in children from a semi-urban city in north India. Methods: In this open labelled, randomized controlled trial 200 children with acute watery diarrhoea, aged between 6 months to 5 years visiting outpatient department and emergency room of a teaching hospital in north India were enrolled. The children were randomized into receiving either Lactobacillus GG in dose of 10 billion cfu/day for five days or no probiotic medication in addition to standard WHO management of diarrhoea. Primary outcomes were duration of diarrhoea and time to change in consistency of stools. Results: Median (inter quartile range) duration of diarrhoea was significantly shorter in children in LGG group [60 (54-72) h vs. 78 (72-90) h; P<0.001]. Also, there was faster improvement in stool consistency in children receiving Lactobacillus GG than control group [36 (30-36) h vs. 42 (36-48) h; P<0.001]. There was significant reduction in average number of stools per day in LGG group (P<0.001) compared to the control group. These benefits were seen irrespective of rotavirus positivity in stool tests. Interpretation & conclusions: Our results showed that the use of Lactobacillus GG in children with acute diarrhoea resulted in shorter duration and faster improvement in stool consistency as compared to the control group. PMID:24820831
Belcaro, G; Feragalli, B; Cornelli, U; Dugall, M
2015-10-22
This case report (supplement registry study) evaluated subjects with painful 'stress' arthritis of the hand mainly localized at the joints. The patients received a suggestion to follow a rehabilitation plan (standard management; SM). A second group also used the same SM in association with the oral, pharma-standard supplement FlexiQule (Alchem) a new standardized, phytosomal preparation manufactured from the Boswellia plant, which can be used for self-management in inflammatory conditions (150 mg / 3 times daily). The two resulting registry groups included 12 subjects using SM+Flexiqule and and 11 controls (SM only). The groups were comparable. Serology showed no significant alterations: only ESR was slightly elevated (minimal elevation). After 2 weeks, the ESR was normal in the supplement group and mildly elevated in controls (p<0.05%). The decrease in hypertermic areas was greater/faster (p<0.05) in the supplement group. The identification of a working stress and the localization to the dominant hand was comparable in both groups. At 2 weeks, the decrease in pain was significantly faster and more important with the supplement (p<0.05). The hand became more usable in time and the score was better with the supplement (p<0.05). No supplemented patient had to use other drugs, while in the control group 3 subjects eventually used NSAIDs to control pain and stiffness and one used corticosteroids. In conclusion, the natural extract Flexiqule was effective in controlling work-related stress arthritis (without inflammaìtory signs) over a 2 weeks period, better than only Standard Management. More prolonged and larger studies are needed.
Kinoshita, Akitoshi; Kurosawa, Yoshihiro; Kondoh, Kensuke; Suzuki, Toshio; Manabe, Atsushi; Inukai, Takeshi; Sugita, Kanji; Nakazawa, Shinpei
2003-03-01
To test whether a higher sodium dose in the hydration solution may facilitate faster methotrexate (MTX) elimination as compared with a lower sodium dose following high-dose MTX (HDMTX) treatment. Intravenous solutions with alternate doses of sodium (regimen A 70 mEq/l, regimen B 100 mEq/l) were given to 30 children with acute lymphoblastic leukemia in two courses of HDMTX in a randomized crossover fashion. The plasma MTX concentrations every 24 h from the beginning of MTX administration and the adverse events associated with HDMTX were compared between the two hydration regimens. The plasma MTX concentrations were similar in the two hydration regimens at 24 h (A 50.9+/-7.4 vs B 40.9+/-5.4 microM, means+/- SE, P=0.17), but was significantly lower in regimen B at 48 and 72 h (A 0.65+/-0.17 vs B 0.27+/-0.03 microM, P=0.04; and A 0.14+/-0.03 vs B 0.05+/-0.01 microM, P=0.003). The time during which MTX plasma concentrations exceeded 0.1 microM was significantly longer in regimen A than in regimen B (A 3.83+/-0.18 vs B 3.13+/-0.06 days, P=0.001). The incidences of adverse events were similar between the two regimens ( P=0.78), and severe adverse events were not seen in either regimen. Hydration with a higher sodium dose facilitated faster MTX elimination following HDMTX. Sodium may have a beneficial effect on MTX-induced nephrotoxicity.
Salihu, Lejla; Rüst, Christoph Alexander; Rosemann, Thomas; Knechtle, Beat
2016-04-30
Recent studies reported that the sex difference in performance in ultra-endurance sports such as swimming and cycling changed over the years. However, the aspect of drafting in draft-legal ultra-endurance races has not yet been investigated. This study investigates the sex difference in ultra-swimming and ultra-cycling draft-legal races where drafting - swimming or cycling behind other participants to save energy and have more power at the end of the race to overtake them, is allowed. The change in performance of the annual best and the annual three best in an ultra-endurance swimming race (16-km 'Faros Swim Marathon') over 38 years and in a 24-h ultra-cycling race ('World Cycling Race') over 13 years were compared and analysed with respect to sex difference. Furthermore, performances of the fastest female and male finishers ever were compared. In the swimming event, the sex difference of the annual best male and female decreased non-significantly (P = 0.262) from 5.3% (1976) to 1.0% (2013). The sex gap of speed in the annual three fastest swimmers decreased significantly (P = 0.043) from 5.9 ± 1.6% (1979) to 4.7 ± 3.1% (2013). In the cycling event, the difference in cycling speed between the annual best male and female decreased significantly (P = 0.026) from 33.31% (1999) to 10.89% (2011). The sex gap of speed in the annual three fastest decreased significantly (P = 0.001) from 32.9 ± 0.6% (1999) to 16.4 ± 5.9% (2011). The fastest male swimmer ever (swimming speed 5.3 km/h, race time: 03:01:55 h:min:s) was 1.5% faster than the fastest female swimmer (swimming speed 5.2 km/h, race time: 03:04:09 h:min:s). The three fastest male swimmers ever (mean 5.27 ± 0.13 km/h) were 4.4% faster than the three fastest female swimmers (mean 5.05 ± 0.20 km/h) (P < 0.05). In the cycling event, the best male ever (cycling speed 45.8 km/h) was 26.4% faster than the best female (cycling speed 36.1 km/h). The three fastest male cyclists ever (45.9 km/h) (mean 45.85 ± 0.05 km/h) were 32.1% faster (P < 0.05) than the three fastest female cyclists ever (34.7 km/h) (mean 34.70 ± 1.87 km/h). In summary, in draft-legal ultra-distance events such as swimming and cycling, the sex difference in the annual top and annual top three swimmers and cyclists decreased (i.e. non-linearly in swimmers and linearly in cyclists) over the years. The sex difference of the fastest athletes ever was smaller in swimming (1.5%) than in cycling (26.4%). This finding is different from reports about races where drafting was not possible or even prohibited and where the sex difference remained stable over years.
Jaffe-Dax, Sagi; Frenkel, Or; Ahissar, Merav
2017-01-01
Dyslexia is a prevalent reading disability whose underlying mechanisms are still disputed. We studied the neural mechanisms underlying dyslexia using a simple frequency-discrimination task. Though participants were asked to compare the two tones in each trial, implicit memory of previous trials affected their responses. We hypothesized that implicit memory decays faster among dyslexics. We tested this by increasing the temporal intervals between consecutive trials, and by measuring the behavioral impact and ERP responses from the auditory cortex. Dyslexics showed a faster decay of implicit memory effects on both measures, with similar time constants. Finally, faster decay of implicit memory also characterized the impact of sound regularities in benefitting dyslexics' oral reading rate. Their benefit decreased faster as a function of the time interval from the previous reading of the same non-word. We propose that dyslexics’ shorter neural adaptation paradoxically accounts for their longer reading times, since it reduces their temporal window of integration of past stimuli, resulting in noisier and less reliable predictions for both simple and complex stimuli. Less reliable predictions limit their acquisition of reading expertise. DOI: http://dx.doi.org/10.7554/eLife.20557.001 PMID:28115055
Net endogenous acid production is associated with a faster decline in GFR in African Americans
Scialla, Julia J.; Appel, Lawrence J.; Astor, Brad C.; Miller, Edgar R.; Beddhu, Srinivasan; Woodward, Mark; Parekh, Rulan S.; Anderson, Cheryl A. M.
2012-01-01
Increased acid excretion may promote renal injury. To evaluate this in African Americans with hypertensive nephrosclerosis, we studied the association between the net endogenous acid production and progression of kidney disease in 632 patients in the AASK trial. Protein and potassium intakes were estimated from 24-hour urea nitrogen and potassium excretion, and used to estimate net endogenous acid production, averaged over 2 years, approximating routine intake. The link between net endogenous acid production and the I125iothalamate glomerular filtration rate (iGFR) and time to end stage renal disease or doubling of serum creatinine was analyzed using mixed models and Cox proportional hazards regressions. The trend in higher net endogenous acid production was significantly associated with a faster decline in iGFR over a median of 3.2 years. After adjustment for age, body mass index, baseline iGFR, urine protein to creatinine ratio and randomized treatment group, the trend in higher net endogenous acid production remained significantly associated with a faster decline in iGFR at a rate 1.01 mL/min/1.73 m2 per year faster in the highest to the lowest quartile. However, in time to event analyses over a median of 7.7 years, the adjusted hazard ratio (1.10) for composite renal events per 25 mEq/day higher net endogenous acid production was not significant. Hence, our findings implicate endogenous acid production as a potential modifiable risk factor for progressive kidney disease. PMID:22475819
Consolidation of lunar regolith: Microwave versus direct solar heating
NASA Technical Reports Server (NTRS)
Kunitzer, J.; Strenski, D. G.; Yankee, S. J.; Pletka, B. J.
1991-01-01
The production of construction materials on the lunar surface will require an appropriate fabrication technique. Two processing methods considered as being suitable for producing dense, consolidated products such as bricks are direct solar heating and microwave heating. An analysis was performed to compare the two processes in terms of the amount of power and time required to fabricate bricks of various size. The regolith was considered to be a mare basalt with an overall density of 60 pct. of theoretical. Densification was assumed to take place by vitrification since this process requires moderate amounts of energy and time while still producing dense products. Microwave heating was shown to be significantly faster compared to solar furnace heating for rapid production of realistic-size bricks.
NASA Astrophysics Data System (ADS)
Attia, Khalid A. M.; Nassar, Mohammed W. I.; El-Zeiny, Mohamed B.; Serag, Ahmed
2017-01-01
For the first time, a new variable selection method based on swarm intelligence namely firefly algorithm is coupled with three different multivariate calibration models namely, concentration residual augmented classical least squares, artificial neural network and support vector regression in UV spectral data. A comparative study between the firefly algorithm and the well-known genetic algorithm was developed. The discussion revealed the superiority of using this new powerful algorithm over the well-known genetic algorithm. Moreover, different statistical tests were performed and no significant differences were found between all the models regarding their predictabilities. This ensures that simpler and faster models were obtained without any deterioration of the quality of the calibration.
Huffman and linear scanning methods with statistical language models.
Roark, Brian; Fried-Oken, Melanie; Gibbons, Chris
2015-03-01
Current scanning access methods for text generation in AAC devices are limited to relatively few options, most notably row/column variations within a matrix. We present Huffman scanning, a new method for applying statistical language models to binary-switch, static-grid typing AAC interfaces, and compare it to other scanning options under a variety of conditions. We present results for 16 adults without disabilities and one 36-year-old man with locked-in syndrome who presents with complex communication needs and uses AAC scanning devices for writing. Huffman scanning with a statistical language model yielded significant typing speedups for the 16 participants without disabilities versus any of the other methods tested, including two row/column scanning methods. A similar pattern of results was found with the individual with locked-in syndrome. Interestingly, faster typing speeds were obtained with Huffman scanning using a more leisurely scan rate than relatively fast individually calibrated scan rates. Overall, the results reported here demonstrate great promise for the usability of Huffman scanning as a faster alternative to row/column scanning.
SignalPlant: an open signal processing software platform.
Plesinger, F; Jurco, J; Halamek, J; Jurak, P
2016-07-01
The growing technical standard of acquisition systems allows the acquisition of large records, often reaching gigabytes or more in size as is the case with whole-day electroencephalograph (EEG) recordings, for example. Although current 64-bit software for signal processing is able to process (e.g. filter, analyze, etc) such data, visual inspection and labeling will probably suffer from rather long latency during the rendering of large portions of recorded signals. For this reason, we have developed SignalPlant-a stand-alone application for signal inspection, labeling and processing. The main motivation was to supply investigators with a tool allowing fast and interactive work with large multichannel records produced by EEG, electrocardiograph and similar devices. The rendering latency was compared with EEGLAB and proves significantly faster when displaying an image from a large number of samples (e.g. 163-times faster for 75 × 10(6) samples). The presented SignalPlant software is available free and does not depend on any other computation software. Furthermore, it can be extended with plugins by third parties ensuring its adaptability to future research tasks and new data formats.
A novel one-shot circular stapler closure for atrial septal defect in a beating-heart porcine model.
Tarui, Tatsuya; Tomita, Shigeyuki; Ishikawa, Norihiko; Ohtake, Hiroshi; Watanabe, Go
2015-02-01
In surgical atrial septal defect (ASD) closure, there are no techniques or devices that can close the ASD accurately in a short time under a beating heart. We have developed a simple and automatic ASD closure technique using a circular stapler. This study assessed the feasibility and efficacy of a new circular stapler closure for ASD. Under a continuous beating heart, hand-sewn patch plasty ASD closure was performed in 6 pigs (group A) and circular stapler ASD closure was performed in 6 pigs (group B). The time to close the ASD and the effectiveness of the closure were compared. Closure was significantly faster in group B (10.5 ± 1.0 seconds) than in group A (664 ± 10 seconds; p < 0.05). There was no leakage at the closure site, and sufficient tolerance was confirmed. A circular stapler can be used to treat ASD faster than hand-sewn patch plasty, with sufficient pressure tolerance in a beating heart porcine model. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Application of the low-level laser therapy for the treatment of vaginitis
NASA Astrophysics Data System (ADS)
Passeniouk, A. N.; Mikhailov, V. A.
2000-06-01
Vaginitis is the most common female infectious disease. Females suffering from this disorder are annually increasing in number. There are a lot of modalities of treatment of vaginitis, but because of drug allergy and microbe's stability to drug the treatment of vaginitis is difficult. Our study compares the efficacy of laser-therapy with drug therapy in the treatment of non-specific vaginitis and vaginal candidiasis. Thirty women reci4eed the LLLT by local action with antiseptic liquid daily during ten days, 20 women received metronidazole and fluconozole and vaginal application of metronidazole. The results suggest that local laser-therapy is able to remove sights of vaginitis more efficiently and faster than drug therapy. Repair of normal vaginal microflora, which is the best indicator of recovery, was significantly at a faster rate in laser-therapy group. There were no report of adverse reaction with vaginal laser- therapy, whereas there were women on drug therapy who reported side effects. In conclusion, vaginal aser-therapy with antiseptic liquid is a suitable, effective, safe and chip alternative to drug therapy in the treatment of vaginitis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumaran, D.; Eswaramoorthy, S; Furey, W
2009-01-01
Clostridium botulinum produces seven antigenically distinct neurotoxins [C. botulinum neurotoxins (BoNTs) A-G] sharing a significant sequence homology. Based on sequence and functional similarity, it was believed that their three-dimensional structures will also be similar. Indeed, the crystal structures of BoNTs A and B exhibit similar fold and domain association where the translocation domain is flanked on either side by binding and catalytic domains. Here, we report the crystal structure of BoNT E holotoxin and show that the domain association is different and unique, although the individual domains are similar to those of BoNTs A and B. In BoNT E, bothmore » the binding domain and the catalytic domain are on the same side of the translocation domain, and all three have mutual interfaces. This unique association may have an effect on the rate of translocation, with the molecule strategically positioned in the vesicle for quick entry into cytosol. Botulism, the disease caused by BoNT E, sets in faster than any other serotype because of its speedy internalization and translocation, and the present structure offers a credible explanation. We propose that the translocation domain in other BoNTs follows a two-step process to attain translocation-competent conformation as in BoNT E. We also suggest that this translocation-competent conformation in BoNT E is a probable reason for its faster toxic rate compared to BoNT A. However, this needs further experimental elucidation.« less
Stimulation of pontine reticular formation in monkeys with strabismus.
Walton, Mark M G; Ono, Seiji; Mustari, Michael J
2013-10-29
Saccade disconjugacy in strabismus could result from any of a number of factors, including abnormalities of eye muscles, the plant, motoneurons, near response cells, or atypical tuning of neurons in saccade-related areas of the brain. This study was designed to investigate the possibility that saccade disconjugacy in strabismus is associated with abnormalities in paramedian pontine reticular formation (PPRF). We applied microstimulation to 22 sites in PPRF and 20 sites in abducens nucleus in three rhesus macaque monkeys (one normal, one esotrope, and one exotrope). When mean velocity was compared between the two eyes, a slight difference was found for 1/5 sites in the normal animal. Significant differences were found for 5/6 sites in an esotrope and 10/11 sites in an exotrope. For five sites in the strabismic monkeys, the directions of evoked movements differed by more than 40° between the two eyes. When stimulation was applied to abducens nucleus (20 sites), the ipsilateral eye moved faster for 4/6 sites in the normal animal and all nine sites in the esotrope. For the exotrope, however, the left eye always moved faster, even for three sites on the right side. For the strabismic animals, stimulation of abducens nucleus often caused a different eye to move faster than stimulation of PPRF. These data suggest that PPRF is organized at least partly monocularly in strabismus and that disconjugate saccades are at least partly a consequence of unbalanced saccadic commands being sent to the two eyes.
Shaikhouni, Ammar
2017-01-01
Converging evidence suggests that reinstatement of neural activity underlies our ability to successfully retrieve memories. However, the temporal dynamics of reinstatement in the human cortex remain poorly understood. One possibility is that neural activity during memory retrieval, like replay of spiking neurons in the hippocampus, occurs at a faster timescale than during encoding. We tested this hypothesis in 34 participants who performed a verbal episodic memory task while we recorded high gamma (62–100 Hz) activity from subdural electrodes implanted for seizure monitoring. We show that reinstatement of distributed patterns of high gamma activity occurs faster than during encoding. Using a time-warping algorithm, we quantify the timescale of the reinstatement and identify brain regions that show significant timescale differences between encoding and retrieval. Our data suggest that temporally compressed reinstatement of cortical activity is a feature of cued memory retrieval. SIGNIFICANCE STATEMENT We show that cued memory retrieval reinstates neural activity on a faster timescale than was present during encoding. Our data therefore provide a link between reinstatement of neural activity in the cortex and spontaneous replay of cortical and hippocampal spiking activity, which also exhibits temporal compression, and suggest that temporal compression may be a universal feature of memory retrieval. PMID:28336569
2016-05-01
In order to detect the effects of simulated nitrogen deposition on litter decomposition and degradation of lignin and cellulose, a one-year field experiment of simulated nitrogen deposition has been conducted using litter bag method from November 2013 to November 2014 in an evergreen broad-leaved forest, Rainy Area of West China. Four levels of nitrogen deposition were set, i.e., control (0 g N·m -2 ·a -1 ), low (5 g N·m -2 ·a -1 ), medium (15 g N·m -2 ·a -1 ) and high (30 g N·m -2 ·a -1 ) nitrogen deposition. The results indicated that foliar litter decomposed faster in summer, obviously faster than in the other seasons. N deposition significantly inhibited the decomposition of foliar litter in this evergreen broad-leaved forest. As N deposition increased, the inhibition effect was enhanced. The time of 95% mass loss (T 95% ) of foliar litter due to simulated N deposition was increased by 0.53-1.88 years compared with T 95% of control (4.81 years). N deposition significantly inhibited the degradation of lignin and cellulose. The mass remaining after one year of decomposition of lignin and cellulose in the medium and high nitrogen deposition treatments were significantly higher than that in the control. There was a significant positive linear relationship among mass remaining rate and lignin and cellulose remaining rates. The inhibiting effects of inorga-nic N on degradation of lignin and cellulose explained the inhibitory effect of N on foliar litter decomposition.
Motion analysis of throwing Boccia balls in children with cerebral palsy.
Huang, Po-Chang; Pan, Po-Jung; Ou, Yu-Chih; Yu, Yi-Chen; Tsai, Yung-Shen
2014-02-01
Boccia is a sport suitable for children with cerebral palsy (CP). Throwing Boccia balls requires upper extremity and torso coordination. This study investigated the differences between children with CP and normally developed children regarding throwing patterns of Boccia balls. Thirteen children with bilateral spastic CP and 20 normally developed children participated in this study. The tests in this study were a pediatric reach test and throwing of Boccia balls. A 3D electromagnetic motion tracking system and a force plate were synchronized to record and analyze biomechanical parameters of throwing Boccia balls. The results of the pediatric reach test for participants with CP were significantly worse than those for normally developed participants. The 2 groups of participants did not significantly differ regarding the distance between a thrown Boccia ball and a target ball (jack). Participants with CP demonstrated significantly longer movement duration, smaller amplitude of elbow movement, greater amplitudes of shoulder abduction and flexion, slower maximal velocity of torso flexion and the linear velocity of moving the wrist joint forward, faster maximal velocity of head flexion, and smaller sway ratio compared with normally developed participants when throwing Boccia balls. Participants with CP seemed to mainly use head and shoulder movements to bring the Boccia balls forward with limited torso movement. Normally developed participants brought the Boccia ball forward with faster torso and greater elbow movement while stabilizing head and shoulder movements. Nevertheless, participants with CP did not demonstrate significantly worse performance in the throwing accuracy of Boccia balls. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mortimer, P.S.; Simmonds, R.; Rezvani, M.
1990-12-01
The measurement of skin lymph flow was investigated using an isotope clearance technique (ICT). Multiple lymph flow determinations were undertaken in the skin of anaesthetized large white pigs to test for reproducibility, ascertain the most suitable tracer, study the influence of injection dynamics, and observe the effect of massage as a stimulus to lymph flow. Blood clearance of tracer was also investigated. Results demonstrated that lymphatic clearance is a monoexponential function with good reproducibility under controlled laboratory conditions. 99mTc-colloid (TCK17 Cis) compared favorably with 131I-human serum albumin as a tracer and both performed better than colloid gold (198Au). Lymph flowmore » was significantly faster in one pig than in the other. No difference existed between left and right sides or between caudal and rostral sites on each flank, but clearance was significantly slower in thigh than flank skin. Sub-epidermal injections cleared faster and more consistently than either deep or subcutaneous injections. Neither injection volume nor needle tract backflow of tracer influenced results, but local massage significantly enhanced clearance. Escape of 99mTc-colloid by the blood was negligible. These results indicate that skin lymph flow can be reliably measured when conditions are controlled. Extrinsic factors such as massage strongly influence lymph flow. Greater sensitivity in detecting degrees of lymphatic insufficiency may be achieved if a standardized stimulus to lymph flow is administered during isotope clearance measurement.« less
[Are there any differences in the working memory of men and women?].
Talarowska, Monika; Florkowski, Antoni; Chamielec, Marcelina; Gałecki, Piotr
2013-01-01
The aim of the study was to compare the implementation of the Stroop test among women and men and to answer the question of the existence of differences in verbal working memory performance and efficiency of attention between representatives of both sexes. A sample of 348 persons aged 20-68 years (mean age: M = 42.16 years) participated in the study: 187 women (53.73%) and 161 men (42.26%). Patients who took part in the investigation were divided into several groups: depressive disorders (DD, n = 146), diabetes type 1 (DM1, n = 31), diabetes type 2 (DM2, n = 31), patients with hypertension (HA, n = 30) and healthy controls (HC, n=110). Cognitive functions were evaluated by the Stroop test. There were no significant differences between men and women in making the first (p = 0.831) and the second part of the Stroop test (p = 0.055). However, it should be noted that the difference between men and 'omen in the speed of the second part of the test is close to significance. Women performed the test faster than men, while men have committed in other parts of the test less errors (p = 0.441). In the present study there was no statistically significant differences between men and women in the implementation of both parts of the Stroop test. Women performed both part of the Stroop test faster than men do but the latter make fewer mistakes.
Vazini Taher, Amir; Parnow, Abdolhossein
2017-05-01
Different methods of warm-up may have implications in improving various aspects of soccer performance. The present study aimed to investigate acute effects of soccer specific warm-up protocols on functional performance tests. This study using randomized within-subject design, investigated the performance of 22 collegiate elite soccer player following soccer specific warm-ups using dynamic stretching, static stretching, and FIFA 11+ program. Post warm-up examinations consisted: 1) Illinois Agility Test; 2) vertical jump; 3) 30 meter sprint; 4) consecutive turns; 5) flexibility of knee. Vertical jump performance was significantly lower following static stretching, as compared to dynamic stretching (P=0.005). Sprint performance declined significantly following static stretching as compared to FIFA 11+ (P=0.023). Agility time was significantly faster following dynamic stretching as compared to FIFA 11+ (P=0.001) and static stretching (P=0.001). Knee flexibility scores were significantly improved following the static stretching as compared to dynamic stretching (P=016). No significant difference was observed for consecutive turns between three warm-up protocol. The present finding showed that a soccer specific warm-up protocol relied on dynamic stretching is preferable in enhancing performance as compared to protocols relying on static stretches and FIFA 11+ program. Investigators suggest that while different soccer specific warm-up protocols have varied types of effects on performance, acute effects of dynamic stretching on performance in elite soccer players are assured, however application of static stretching in reducing muscle stiffness is demonstrated.
Equipment for Hot-to-serve Foods
NASA Technical Reports Server (NTRS)
Smith, D. P.
1985-01-01
Patented surface heating devices with a much faster air-to-solid heat transfer rate than previous air ovens were developed. The accelerated surface heating can brown, sear or crisp much more rapidly than in conventional ovens so that partially prepared food can be finished quickly and tastefully immediately before serving. The crisp, freshly browned surfaces result from the faster heat transfer which does not dry out the food. The devices are then compared to convection ovens and microwave heating processes.
The use of the modified Cholesky decomposition in divergence and classification calculations
NASA Technical Reports Server (NTRS)
Vanroony, D. L.; Lynn, M. S.; Snyder, C. H.
1973-01-01
The use of the Cholesky decomposition technique is analyzed as applied to the feature selection and classification algorithms used in the analysis of remote sensing data (e.g. as in LARSYS). This technique is approximately 30% faster in classification and a factor of 2-3 faster in divergence, as compared with LARSYS. Also numerical stability and accuracy are slightly improved. Other methods necessary to deal with numerical stablity problems are briefly discussed.
The use of the modified Cholesky decomposition in divergence and classification calculations
NASA Technical Reports Server (NTRS)
Van Rooy, D. L.; Lynn, M. S.; Snyder, C. H.
1973-01-01
This report analyzes the use of the modified Cholesky decomposition technique as applied to the feature selection and classification algorithms used in the analysis of remote sensing data (e.g., as in LARSYS). This technique is approximately 30% faster in classification and a factor of 2-3 faster in divergence, as compared with LARSYS. Also numerical stability and accuracy are slightly improved. Other methods necessary to deal with numerical stability problems are briefly discussed.
Beltrame, Thomas; Villar, Rodrigo; Hughson, Richard L
2017-09-01
Previous studies in children and older adults demonstrated faster oxygen uptake (V̇O 2 ) kinetics in males compared with females, but young healthy adults have not been studied. We hypothesized that young men would have faster aerobic system dynamics in response to the onset of exercise than women. Interactions between oxygen supply and utilization were characterized by the dynamics of V̇O 2 , deoxyhemoglobin (HHb), tissue saturation index (TSI), cardiac output (Q̇), and calculated arteriovenous O 2 difference (a-vO 2 diff ) in women and men. Eighteen healthy active young women and men (9 of each sex) with similar aerobic fitness levels volunteered for this study. Participants performed an incremental cardiopulmonary treadmill exercise test and 3 moderate-intensity treadmill exercise tests (at 80% V̇O 2 of gas exchange threshold). Data related to the moderate exercise were submitted to exponential data modelling to obtain parameters related to the aerobic system dynamics. The time constants of V̇O 2 , a-vO 2 diff , HHb, and TSI (30 ± 6, 29 ± 1, 16 ± 1, and 15 ± 2 s, respectively) in women were statistically (p < 0.05) faster than the time constants in men (42 ± 10, 49 ± 21, 19 ± 3, and 20 ± 4 s, respectively). Although Q̇ dynamics were not statistically different (p = 0.06) between groups, there was a trend to slower Q̇ dynamics in men corresponding with the slower V̇O 2 kinetics. These results indicated that the peripheral and pulmonary oxygen extraction dynamics were remarkably faster in women. Thus, contrary to the hypothesis, V̇O 2 dynamics measured at the mouth at the onset of submaximal treadmill walking were faster in women compared with men.
Modifications of the PCPT method for HJB equations
NASA Astrophysics Data System (ADS)
Kossaczký, I.; Ehrhardt, M.; Günther, M.
2016-10-01
In this paper we will revisit the modification of the piecewise constant policy timestepping (PCPT) method for solving Hamilton-Jacobi-Bellman (HJB) equations. This modification is called piecewise predicted policy timestepping (PPPT) method and if properly used, it may be significantly faster. We will quickly recapitulate the algorithms of PCPT, PPPT methods and of the classical implicit method and apply them on a passport option pricing problem with non-standard payoff. We will present modifications needed to solve this problem effectively with the PPPT method and compare the performance with the PCPT method and the classical implicit method.
The yield of different pleural fluid volumes for Mycobacterium tuberculosis culture.
von Groote-Bidlingmaier, Florian; Koegelenberg, Coenraad Frederik; Bolliger, Chris T; Chung, Pui Khi; Rautenbach, Cornelia; Wasserman, Elizabeth; Bernasconi, Maurizio; Friedrich, Sven Olaf; Diacon, Andreas Henri
2013-03-01
We prospectively compared the culture yields of two pleural fluid volumes (5 and 100 ml) inoculated in liquid culture medium in 77 patients of whom 58 (75.3%) were diagnosed with pleural tuberculosis. The overall fluid culture yield was high (60.3% of cases with pleural tuberculosis). The larger volume had a faster time to positivity (329 vs 376 h, p=0.055) but its yield was not significantly higher (53.5% vs 50%; p=0.75). HIV-positive patients were more likely to have positive cultures (78.9% vs 51.5%; p=0.002).
Electromagnetic energy dispersion in a 5D universe
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hartnett, John G.
2010-06-15
Electromagnetism is analyzed in a 5D expanding universe. Compared to the usual 4D description of electrodynamics it can be viewed as adding effective charge and current densities to the universe that are static in time. These lead to effective polarization and magnetization of the vacuum, which is most significant at high redshift. Electromagnetic waves propagate but group and phase velocities are dispersive. This introduces a new energy scale to the cosmos. And as a result electromagnetic waves propagate with superluminal speeds but no energy is transmitted faster than the canonical speed of light c.
Culture, attention, and emotion.
Grossmann, Igor; Ellsworth, Phoebe C; Hong, Ying-yi
2012-02-01
This research provides experimental evidence for cultural influence on one of the most basic elements of emotional processing: attention to positive versus negative stimuli. To this end, we focused on Russian culture, which is characterized by brooding and melancholy. In Study 1, Russians spent significantly more time looking at negative than positive pictures, whereas Americans did not show this tendency. In Study 2, Russian Latvians were randomly primed with symbols of each culture, after which we measured the speed of recognition for positive versus negative trait words. Biculturals were significantly faster in recognizing negative words (as compared with baseline) when primed with Russian versus Latvian cultural symbols. Greater identification with Russian culture facilitated this effect. We provide a theoretical discussion of mental processes underlying cultural differences in emotion research.
NASA Astrophysics Data System (ADS)
Kimball, Jorja; Cole, Bryan; Hobson, Margaret; Watson, Karan; Stanley, Christine
This paper reports findings on gender that were part of a larger study reviewing time to completion of course work that includes the first two semesters of calculus, chemistry, and physics, which are often considered the stumbling points or "barrier courses" to an engineering baccalaureate degree. Texas A&M University terms these courses core body of knowledge (CBK), and statistical analysis was conducted on two cohorts of first-year enrolling engineering students at the institution. Findings indicate that gender is statistically significantly related to completion of CBK with female engineering students completing required courses faster than males at the .01 level (p = 0.008). Statistical significance for gender and ethnicity was found between white male and white female students at the .01 level (p = 0.008). Descriptive analysis indicated that of the five majors studied (chemical, civil, computer, electrical, and mechanical engineering), women completed CBK faster than men, and African American and Hispanic women completed CBK faster than males of the same ethnicity.
What difference reveals about similarity.
Sagi, Eyal; Gentner, Dedre; Lovett, Andrew
2012-08-01
Detecting that two images are different is faster for highly dissimilar images than for highly similar images. Paradoxically, we showed that the reverse occurs when people are asked to describe how two images differ--that is, to state a difference between two images. Following structure-mapping theory, we propose that this disassociation arises from the multistage nature of the comparison process. Detecting that two images are different can be done in the initial (local-matching) stage, but only for pairs with low overlap; thus, "different" responses are faster for low-similarity than for high-similarity pairs. In contrast, identifying a specific difference generally requires a full structural alignment of the two images, and this alignment process is faster for high-similarity pairs. We described four experiments that demonstrate this dissociation and show that the results can be simulated using the Structure-Mapping Engine. These results pose a significant challenge for nonstructural accounts of similarity comparison and suggest that structural alignment processes play a significant role in visual comparison. Copyright © 2012 Cognitive Science Society, Inc.
Zafar, M Urooj; Baber, Usman; Smith, Donald A; Sartori, Samantha; Contreras, Johanna; Rey-Mendoza, Juan; Linares-Koloffon, Carlos A; Escolar, Gines; Mehran, Roxana; Fuster, Valentin; Badimon, Juan J
2017-10-05
Type-2 Diabetes Mellitus [T2DM] is associated with increased platelet reactivity and hypo-response to antiplatelet drugs. Ticagrelor, with its faster and more potent antiplatelet effects, was shown to reduce adverse events more than clopidogrel in the overall CAD patient population of PLATO trial, but the benefits did not reach statistical significance in the T2DM subgroup. To better understand these findings, we compared the antithrombotic effects of ticagrelor versus with clopidogrel in T2DM patients with cardiovascular disease. In a randomized, 2 treatment-sequence, crossover-design, T2DM patients (n=20, 57±8 years, 60 % male) received a loading-dose [LD] plus one week of daily-therapy [DT] of clopidogrel or ticagrelor. Treatment effects were assessed by measuring thrombus formation (Badimon Chamber) and platelet aggregation (Multiple Electrode Aggregometry (MEA) Analyzer and VerifyNow®) at 2- and 6-hour post-LD and on Day-7 of DT, in comparison with pre-treatment baseline. After 2 weeks of washout, patients switched to the second treatment under identical testing conditions. Ticagrelor significantly reduced thrombus formation versus baseline at 2- and 6-hour post-LD and Day-7 of DT (33 %, 40 % and 31 %, respectively, p<0.01 for all) whereas thrombus reductions with clopidogrel were much lower and significant only at 6-hour post-LD (16 %, 20 % and 17 %, respectively). Antithrombotic effect of ticagrelor at 6-hour was significantly stronger than clopidogrel (p<0.05). Platelet aggregation (MEA and VerifyNow®) was inhibited by both treatments but effects of ticagrelor were significantly stronger at each time-point. Ticagrelor exhibits a faster and more potent antithrombotic effect than clopidogrel in T2DM patients with cardiovascular disease, supporting its use in this population.
Efficient Geometric Sound Propagation Using Visibility Culling
NASA Astrophysics Data System (ADS)
Chandak, Anish
2011-07-01
Simulating propagation of sound can improve the sense of realism in interactive applications such as video games and can lead to better designs in engineering applications such as architectural acoustics. In this thesis, we present geometric sound propagation techniques which are faster than prior methods and map well to upcoming parallel multi-core CPUs. We model specular reflections by using the image-source method and model finite-edge diffraction by using the well-known Biot-Tolstoy-Medwin (BTM) model. We accelerate the computation of specular reflections by applying novel visibility algorithms, FastV and AD-Frustum, which compute visibility from a point. We accelerate finite-edge diffraction modeling by applying a novel visibility algorithm which computes visibility from a region. Our visibility algorithms are based on frustum tracing and exploit recent advances in fast ray-hierarchy intersections, data-parallel computations, and scalable, multi-core algorithms. The AD-Frustum algorithm adapts its computation to the scene complexity and allows small errors in computing specular reflection paths for higher computational efficiency. FastV and our visibility algorithm from a region are general, object-space, conservative visibility algorithms that together significantly reduce the number of image sources compared to other techniques while preserving the same accuracy. Our geometric propagation algorithms are an order of magnitude faster than prior approaches for modeling specular reflections and two to ten times faster for modeling finite-edge diffraction. Our algorithms are interactive, scale almost linearly on multi-core CPUs, and can handle large, complex, and dynamic scenes. We also compare the accuracy of our sound propagation algorithms with other methods. Once sound propagation is performed, it is desirable to listen to the propagated sound in interactive and engineering applications. We can generate smooth, artifact-free output audio signals by applying efficient audio-processing algorithms. We also present the first efficient audio-processing algorithm for scenarios with simultaneously moving source and moving receiver (MS-MR) which incurs less than 25% overhead compared to static source and moving receiver (SS-MR) or moving source and static receiver (MS-SR) scenario.
Muir, Stacy L; Sheppard, Lance B; Maika-Wilson, Anne; Burgert, James M; Garcia-Blanco, Jose; Johnson, Arthur D; Coyner, Jennifer L
2016-08-01
Introduction Obtaining intravenous (IV) access in patients in hemorrhagic shock is often difficult and prolonged. Failed IV attempts delay life-saving treatment. Intraosseous (IO) access may often be obtained faster than IV access. Albumin (5%) is an option for prehospital volume expansion because of the absence of interference with coagulation and platelet function. Hypothesis/Problem There are limited data comparing the performance of IO and IV administered 5% albumin. The aims of this study were to compare the effects of tibial IO (TIO) and IV administration of 500 mL of 5% albumin on infusion time and hemodynamic measurements of heart rate (HR), mean arterial pressure (MAP), cardiac output (CO), and stroke volume (SV) in a swine model of hemorrhagic shock. Sixteen male swine were divided into two groups: TIO and IV. All subjects were anesthetized and a Class III hemorrhage was achieved by exsanguination of 31% of estimated blood volume (EBV) from a femoral artery catheter. Following exsanguination, 500 mL of 5% albumin was administered under pressurized infusion (300 mmHg) by the TIO or IV route and infusion time was recorded. Hemodynamic measurements of HR, MAP, CO, and SV were collected before and after exsanguination and every 20 seconds for 180 seconds during 5% albumin infusion. An independent t-test determined that IV 5% albumin infusion was significantly faster compared to IO (P=.01). Mean infusion time for TIO was seven minutes 35 seconds (SD=two minutes 44 seconds) compared to four minutes 32 seconds (SD=one minute 08 seconds) in the IV group. Multivariate Analysis of Variance was performed on hemodynamic data collected during the 5% albumin infusion. Analyses indicated there were no significant differences between the TIO and IV groups relative to MAP, CO, HR, or SV (P>.05). While significantly longer to infuse 5% albumin by the TIO route, the longer TIO infusion time may be negated as IO devices can be placed more quickly compared to repeated IV attempts. The lack of significant difference between the TIO and IV routes relative to hemodynamic measures indicate the TIO route is a viable route for the infusion of 5% albumin in a swine model of Class III hemorrhage. Muir SL , Sheppard LB , Maika-Wilson A , Burgert JM , Garcia-Blanco J , Johnson AD , Coyner JL . A comparison of the effects of intraosseous and intravenous 5% albumin on infusion time and hemodynamic measures in a swine model of hemorrhagic shock. Prehosp Disaster Med. 2016;31(4):436-442.
Mañas-Jordá, Saray; León-Cortés, Jorge L; García-García, María D; Caballero, Ubaldo; Infante, Francisco
2018-01-10
A comparative study of Diptera communities associated with pig carcasses was carried out in urban and natural settings in tropical mountain habitats of Southern Mexico. Schoenly-type traps were used to set out pig carcasses during 68 d of sampling effort. In total, 1,703 adult Diptera specimens were collected in both localities combined, and recording a total of 30 (morpho) species and 19 families. Compared to natural habitats, a significantly greater diversity in urban habitats, as well as a faster decomposition process of carcasses, was detected. Significant differences were also detected for the composition and structure of Dipteran communities between urban and natural sites. Dominant species of Calliphoridae for natural and urban habitats were represented by Compsomyiops spp. and Cochliomyia macellaria (Fabricius; Diptera: Calliphoridae), respectively. The properties of indicator species for urban and natural sites are discussed. Twenty Dipteran species were significantly associated to different decomposition stages. Such affinity would allow for estimating the post-mortem interval (PMI) in comparable situations. © The Author(s) 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Faster proton transfer dynamics of water on SnO2 compared to TiO2.
Kumar, Nitin; Kent, Paul R C; Bandura, Andrei V; Kubicki, James D; Wesolowski, David J; Cole, David R; Sofo, Jorge O
2011-01-28
Proton jump processes in the hydration layer on the iso-structural TiO(2) rutile (110) and SnO(2) cassiterite (110) surfaces were studied with density functional theory molecular dynamics. We find that the proton jump rate is more than three times faster on cassiterite compared with rutile. A local analysis based on the correlation between the stretching band of the O-H vibrations and the strength of H-bonds indicates that the faster proton jump activity on cassiterite is produced by a stronger H-bond formation between the surface and the hydration layer above the surface. The origin of the increased H-bond strength on cassiterite is a combined effect of stronger covalent bonding and stronger electrostatic interactions due to differences of its electronic structure. The bridging oxygens form the strongest H-bonds between the surface and the hydration layer. This higher proton jump rate is likely to affect reactivity and catalytic activity on the surface. A better understanding of its origins will enable methods to control these rates.
Yoshida, Naohisa; Toyonaga, Takashi; Murakami, Takaaki; Hirose, Ryohei; Ogiso, Kiyoshi; Inada, Yutaka; Rani, Rafiz Abdul; Naito, Yuji; Kishimoto, Mitsuo; Ohara, Yoshiko; Azuma, Takeshi; Itoh, Yoshito
2017-01-01
With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1-28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results.
Walk this way: approaching bodies can influence the processing of faces.
Pilz, Karin S; Vuong, Quoc C; Bülthoff, Heinrich H; Thornton, Ian M
2011-01-01
A highly familiar type of movement occurs whenever a person walks towards you. In the present study, we investigated whether this type of motion has an effect on face processing. We took a range of different 3D head models and placed them on a single, identical 3D body model. The resulting figures were animated to approach the observer. In a first series of experiments, we used a sequential matching task to investigate how the motion of an approaching person affects immediate responses to faces. We compared observers' responses following approach sequences to their performance with figures walking backwards (receding motion) or remaining still. Observers were significantly faster in responding to a target face that followed an approach sequence, compared to both receding and static primes. In a second series of experiments, we investigated long-term effects of motion using a delayed visual search paradigm. After studying moving or static avatars, observers searched for target faces in static arrays of varying set sizes. Again, observers were faster at responding to faces that had been learned in the context of an approach sequence. Together these results suggest that the context of a moving body influences face processing, and support the hypothesis that our visual system has mechanisms that aid the encoding of behaviourally-relevant and familiar dynamic events. Copyright © 2010 Elsevier B.V. All rights reserved.
The Faster, Better, Cheaper Approach to Space Missions: An Engineering Management Assessment
NASA Technical Reports Server (NTRS)
Hamaker, Joseph W.
1999-01-01
NASA was chartered as an independent civilian space agency in 1958 following the Soviet Union's dramatic launch of the Sputnik 1 (1957). In his state of the union address in May of 1961, President Kennedy issued to the fledging organization his famous challenge for a manned lunar mission by the end of the decade. The Mercury, Gemini and Apollo programs that followed put the utmost value on high quality, low risk (as low as possible within the context of space flight), quick results, all with little regard for cost. These circumstances essentially melded NASAs culture as an organization capable of great technological achievement but at extremely high cost. The Space Shuttle project, the next major agency endeavor, was put under severe annual budget constraints in the 1970's. NASAs response was to hold to the high quality standards, low risk and annual cost and let schedule suffer. The result was a significant delay in the introduction of the Shuttle as well as overall total cost growth. By the early 1990's, because NASA's budget was declining, the number of projects was also declining. Holding the same cost and schedule productivity levels as before was essentially causing NASA to price itself out of business. In 1992, the helm of NASA was turned over to a new Administrator. Dan Goldin's mantra was "faster, better, cheaper" and his enthusiasm and determination to change the NASA culture was not to be ignored. This research paper documents the various implementations of "faster, better, cheaper" that have been attempted, analyzes their impact and compares the cost performance of these new projects to previous NASA benchmarks. Fundamentally, many elements of "faster, better, cheaper" are found to be working well, especially on smaller projects. Some of the initiatives are found to apply only to smaller or experimental projects however, so that extrapolation to "flagship" projects may be problematic.
Validating New Software for Semiautomated Liver Volumetry--Better than Manual Measurement?
Noschinski, L E; Maiwald, B; Voigt, P; Wiltberger, G; Kahn, T; Stumpp, P
2015-09-01
This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33% vs. 57%, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04 min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience. Both tested types of software allow exact volumetry of resected liver parts. Preoperative prediction can be performed more accurately with the semiautomated software. The semiautomated software is nearly four times faster than the tested manual program and less dependent on the user's experience. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Technical Reports Server (NTRS)
Le Vine, D. M.; Willett, J.
1988-01-01
Fast electric field changes from subsequent return strokes of natural and triggered lightning with propagation paths almost entirely over water are compared. Data were collected at the Kennedy Space Center, Florida. Comparisons have been made of the average shape, the rise time and the spectrum of the electric field changes. The electric field changes from the triggered flashes tend to rise to peak faster and decay faster than do their counterparts in natural cloud-to-ground flashes.
Analysis of United States’ Broadband Policy
2007-03-01
compared with the minimum speed the FCC uses in its definition of broadband access. For example, using a 56K modem connection to download a 10...transmission rates multiple times faster than a 56K modem , users can view video or download software and other data-intensive files in a matter of seconds...boast download speeds from 144Kbps (roughly three times faster than a 56K dial-up modem connection) to 2.4Mbps (close to cable- modem speed). Although
Johari, Karim; Behroozmand, Roozbeh
2017-08-01
Skilled movement is mediated by motor commands executed with extremely fine temporal precision. The question of how the brain incorporates temporal information to perform motor actions has remained unanswered. This study investigated the effect of stimulus temporal predictability on response timing of speech and hand movement. Subjects performed a randomized vowel vocalization or button press task in two counterbalanced blocks in response to temporally-predictable and unpredictable visual cues. Results indicated that speech and hand reaction time was decreased for predictable compared with unpredictable stimuli. This finding suggests that a temporal predictive code is established to capture temporal dynamics of sensory cues in order to produce faster movements in responses to predictable stimuli. In addition, results revealed a main effect of modality, indicating faster hand movement compared with speech. We suggest that this effect is accounted for by the inherent complexity of speech production compared with hand movement. Lastly, we found that movement inhibition was faster than initiation for both hand and speech, suggesting that movement initiation requires a longer processing time to coordinate activities across multiple regions in the brain. These findings provide new insights into the mechanisms of temporal information processing during initiation and inhibition of speech and hand movement. Copyright © 2017 Elsevier B.V. All rights reserved.
High blood pressure and cognitive decline in mild cognitive impairment.
Goldstein, Felicia C; Levey, Allan I; Steenland, N Kyle
2013-01-01
To determine whether high blood pressure (BP) levels are associated with faster decline in specific cognitive domains. Prospective longitudinal cohort. Uniform Data Set of the National Institutes of Health, National Institute on Aging Alzheimer's Disease Centers. One thousand three hundred eighty-five participants with a diagnosis of mild cognitive impairment (MCI) and measured BP values at baseline and two annual follow-up visits. Neuropsychological test scores and Clinical Dementia Rating Sum of Boxes (CDR Sum) score. Participants with MCI with two or three annual occasions of high BP values (systolic BP ≥140 mmHg or diastolic BP ≥90 mmHg) had significantly faster decline on neuropsychological measures of visuomotor sequencing, set shifting, and naming than those who were normotensive on all three occasions. High systolic BP values were associated as well with faster decline on the CDR Sum score. Hypertension is associated with faster cognitive decline in persons at risk for dementia. © 2012, Copyright the Authors Journal compilation © 2012, The American Geriatrics Society.
High Blood Pressure and Cognitive Decline in Mild Cognitive Impairment
Goldstein, Felicia C.; Levey, Allan I.; Steenland, N. Kyle
2013-01-01
Objectives To determine whether high blood pressure (BP) levels are associated with faster decline in specific cognitive domains. Design Prospective longitudinal cohort. Setting Uniform Data Set of the National Institutes of Health, National Institute on Aging Alzheimer's Disease Centers. Participants One thousand three hundred eighty-five participants with a diagnosis of mild cognitive impairment (MCI) and measured BP values at baseline and two annual follow-up visits. Measurements Neuropsychological test scores and Clinical Dementia Rating Sum of Boxes (CDR Sum) score. Results Participants with MCI with two or three annual occasions of high BP values (systolic BP ≥ 140 mmHg or diastolic BP ≥ 90 mmHg) had significantly faster decline on neuropsychological measures of visuomotor sequencing, set shifting, and naming than those who were normotensive on all three occasions. High systolic BP values were associated as well with faster decline on the CDR Sum score. Conclusion Hypertension is associated with faster cognitive decline in persons at risk for dementia. PMID:23301925
Kaufmann, Amanda; Hitsman, Brian; Goelz, Patricia M; Veluz-Wilkins, Anna; Blazekovic, Sonja; Powers, Lindsay; Leone, Frank T; Gariti, Peter; Tyndale, Rachel F; Schnoll, Robert A
2015-12-01
In samples from controlled randomized clinical trials, a smoker's rate of nicotine metabolism, measured by the 3-hydroxycotinine to cotinine ratio (NMR), predicts response to transdermal nicotine. Replication of this relationship in community-based samples of treatment-seeking smokers may help guide the implementation of the NMR for personalized treatment for nicotine dependence. Data from a community-based sample of treatment seeking smokers (N=499) who received 8weeks of transdermal nicotine and 4 behavioral counseling sessions were used to evaluate associations between the NMR and smoking cessation. Secondary outcomes included withdrawal and craving, depression and anxiety, side effects, and treatment adherence. The NMR was a significant predictor of abstinence (OR=.56, 95% CI: 0.33-0.95, p=.03), with faster metabolizers showing lower quit rates than slower metabolizers (24% vs. 33%). Faster nicotine metabolizers exhibited significantly higher levels of anxiety symptoms over time during treatment, vs. slower metabolizers (NMR x Time interaction: F[3,357]=3.29, p=.02). NMR was not associated with changes in withdrawal, craving, depression, side effects, and treatment adherence (p's>.05). In a community-based sample of treatment-seeking smokers, faster nicotine metabolizers were significantly less likely to quit smoking and showed higher rates of anxiety symptoms during a smoking cessation treatment program, vs. slower nicotine metabolizers. These results provide further evidence that transdermal nicotine is less effective for faster nicotine metabolizers and suggest the need to address cessation-induced anxiety symptoms among these smokers to increase the chances for successful smoking cessation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Chen, David D; Pei, Laura; Chan, John S Y; Yan, Jin H
2012-10-01
Recent research using deliberate amplification of spatial errors to increase motor learning leads to the question of whether amplifying temporal errors may also facilitate learning. We investigated transfer effects caused by manipulating temporal constraints on learning a two-choice reaction time (CRT) task with varying degrees of stimulus-response compatibility. Thirty-four participants were randomly assigned to one of the three groups and completed 120 trials during acquisition. For every fourth trial, one group was instructed to decrease CRT by 50 msec. relative to the previous trial and a second group was instructed to increase CRT by 50 msec. The third group (the control) was told not to change their responses. After a 5-min. break, participants completed a 40-trial no-feedback transfer test. A 40-trial delayed transfer test was administered 24 hours later. During acquisition, the Decreased Reaction Time group responded faster than the two other groups, but this group also made more errors than the other two groups. In the 5-min. delayed test (immediate transfer), the Decreased Reaction Time group had faster reaction times than the other two groups, while for the 24-hr. delayed test (delayed transfer), both the Decreased Reaction Time group and Increased Reaction Time group had significantly faster reaction times than the control. For delayed transfer, both Decreased and Increased Reaction Time groups reacted significantly faster than the control group. Analyses of error scores in the transfer tests indicated revealed no significant group differences. Results were discussed with regard to the notion of practice variability and goal-setting benefits.
Vera, Angelina M; Russo, Michael; Mohsin, Adnan; Tsuda, Shawn
2014-12-01
Laparoscopic skills training has evolved over recent years. However, conveying a mentor's directions using conventional methods, without realistic on-screen visual cues, can be difficult and confusing. To facilitate laparoscopic skill transference, an augmented reality telementoring (ART) platform was designed to overlay the instruments of a mentor onto the trainee's laparoscopic monitor. The aim of this study was to compare the effectiveness of this new teaching modality to traditional methods in novices performing an intracorporeal suturing task. Nineteen pre-medical and medical students were randomized into traditional mentoring (n = 9) and ART (n = 10) groups for a laparoscopic suturing and knot-tying task. Subjects received either traditional mentoring or ART for 1 h on the validated fundamentals of laparoscopic surgery intracorporeal suturing task. Tasks for suturing were recorded and scored for time and errors. Results were analyzed using means, standard deviation, power regression analysis, correlation coefficient, analysis of variance, and student's t test. Using Wright's cumulative average model (Y = aX (b)) the learning curve slope was significantly steeper, demonstrating faster skill acquisition, for the ART group (b = -0.567, r (2) = 0.92) than the control group (b = -0.453, r (2) = 0.74). At the end of 10 repetitions or 1 h of practice, the ART group was faster versus traditional (mean 167.4 vs. 242.4 s, p = 0.014). The ART group also had fewer fails (8) than the traditional group (13). The ART Platform may be a more effective training technique in teaching laparoscopic skills to novices compared to traditional methods. ART conferred a shorter learning curve, which was more pronounced in the first 4 trials. ART reduced the number of failed attempts and resulted in faster suture times by the end of the training session. ART may be a more effective training tool in laparoscopic surgical training for complex tasks than traditional methods.
Seuss, Hannes; Janka, Rolf; Prümmer, Marcus; Cavallaro, Alexander; Hammon, Rebecca; Theis, Ragnar; Sandmair, Martin; Amann, Kerstin; Bäuerle, Tobias; Uder, Michael; Hammon, Matthias
2017-04-01
Volumetric analysis of the kidney parenchyma provides additional information for the detection and monitoring of various renal diseases. Therefore the purposes of the study were to develop and evaluate a semi-automated segmentation tool and a modified ellipsoid formula for volumetric analysis of the kidney in non-contrast T2-weighted magnetic resonance (MR)-images. Three readers performed semi-automated segmentation of the total kidney volume (TKV) in axial, non-contrast-enhanced T2-weighted MR-images of 24 healthy volunteers (48 kidneys) twice. A semi-automated threshold-based segmentation tool was developed to segment the kidney parenchyma. Furthermore, the three readers measured renal dimensions (length, width, depth) and applied different formulas to calculate the TKV. Manual segmentation served as a reference volume. Volumes of the different methods were compared and time required was recorded. There was no significant difference between the semi-automatically and manually segmented TKV (p = 0.31). The difference in mean volumes was 0.3 ml (95% confidence interval (CI), -10.1 to 10.7 ml). Semi-automated segmentation was significantly faster than manual segmentation, with a mean difference = 188 s (220 vs. 408 s); p < 0.05. Volumes did not differ significantly comparing the results of different readers. Calculation of TKV with a modified ellipsoid formula (ellipsoid volume × 0.85) did not differ significantly from the reference volume; however, the mean error was three times higher (difference of mean volumes -0.1 ml; CI -31.1 to 30.9 ml; p = 0.95). Applying the modified ellipsoid formula was the fastest way to get an estimation of the renal volume (41 s). Semi-automated segmentation and volumetric analysis of the kidney in native T2-weighted MR data delivers accurate and reproducible results and was significantly faster than manual segmentation. Applying a modified ellipsoid formula quickly provides an accurate kidney volume.
Ruan, Ning; Chen, Zhi-hua; Lin, Xia-bing
2013-07-01
To compare the efficacy and complication of tissue selecting therapy stapler (TST) and procedure for prolapse and hemorrhoids (PPH) in the treatment of severe hemorrhoids. Clinical data of 542 cases of severe hemorrhoids undergoing TST (258 cases) or PPH (284 cases) in The First Affiliated Hospital of Fujian Medical University from November 2010 to January 2012 were analyzed retrospectively. Operative parameters, efficacy and complication 3 months after operation were assessed and compared. No significant difference in cure rate between TST and PPH (96.5% vs. 95.4%) was found, while the operation time and hospital stay after operation in TST group were significantly shorter urgency [(20.6±4.7) vs. (26.4±6.3) min, (2.9±0.5) vs. (3.5±0.7) d, both P<0.05]. Incidences of postoperative pain, bleeding, anal urgency and urinary retention in TST group were significantly lower than those in PPH group (all P<0.01). No anal stenosis was observed in TST group, and 5 cases developed anal stenosis in PPH group (P<0.05). Hemorrhoid recurrence did not differ significantly between the two groups. The efficacy of TST and PPH is comparable for severe hemorrhoids patients, while TST is associated with faster postoperative recovery and less complications.
Belci, D; Kos, M; Zoricić, D; Kuharić, L; Slivar, A; Begić-Razem, E; Grdinić, I
2007-06-01
The aim of this study was to evaluate the advantages of the Misgav Ladach surgical technique compared to traditional cesarean section. A prospective randomized trial of 111 women undergoing cesarean section was carried out in the Pula General Hospital. Forty-nine operations were performed using the Pfannenstiel method of cesarean section, 55 by the Misgav Ladach method and 7 by lower midline laparotomy. It was proved that the cases where the Misgav Ladach method was implemented, compared to the Pfannenstiel method, showed a significantly shorter delivery/extraction and operative time (P=0.0009), the incision pain on the second postoperative day was significantly lower (0.021), we recorded a quicker stand up and walking time (P=0.013), significantly fewer analgesic injections and a shorter duration of analgesia were required (P=0.0009) and the bowel function was restored to normal sooner (P=0.001). The Misgav Ladach method of cesarean section has advantages over the Pfannenstiel method in so far as it is significantly quicker to perform, with diminished postoperative pain and less use of postoperative analgesics. The recovery of physiologic function is faster. No differences were found in intraoperative bleeding, maternal morbidity, scar appearance, uterus postoperative involution and the assessment of the inflammation response to the operative technique.
Casas, E; Thallman, R M; Cundiff, L V
2012-09-01
The objective of this study was to characterize breeds representing diverse biological types for birth and weaning traits in crossbred cattle (Bos taurus). Gestation length, calving difficulty, percentage of unassisted calving, percentage of perinatal survival, percentage of survival from birth to weaning, birth weight, weaning weight, BW at 205 d, and ADG was measured in 1,370 calves born and 1,285 calves weaned. Calves were obtained by mating Hereford, Angus, and MARC III (1/4 Hereford, 1/4 Angus, 1/4 Pinzgauer, and 1/4 Red Poll) mature cows to Hereford or Angus (British breeds), Norwegian Red, Swedish Red and White, Wagyu, and Friesian sires. Calves were born during the spring of 1997 and 1998. Sire breed was significant for gestation length, birth weight, BW at 205 d, and ADG (P < 0.001). Offspring from Swedish Red and White and Friesian had the shortest gestation length (282 d), whereas offspring from Wagyu sires had the longest gestation length (286 d). Progeny from British breeds were the heaviest at birth (40.5 kg) and at 205 d (237 kg), and grew faster (0.97 kg/d) than offspring from other breeds. Offspring from Wagyu sires were the lightest at birth (36.3 kg) and at 205 d (214 kg), and had the slowest growth (0.91 kg/d). Dam breed was significant for gestation length (P < 0.001), birth weight (P = 0.009), BW at 205 d, and ADG (P < 0.001). Offspring from Hereford cows had the longest gestation length (284 d), whereas offspring from Angus cows had the shortest (282 d). Offspring from MARC III cows were the heaviest at birth (39.4 kg) when compared with offspring from Hereford (38.2 kg) and Angus (38.6 kg) cows. Progeny from Angus cows were the heaviest at 205 d (235 kg) and grew faster (0.96 kg/d), whereas offspring from Hereford cows were the lightest at 205 d (219 kg) and were the slowest in growth (0.88 kg/d). Sex was significant for gestation length (P = 0.026), birth weight, BW at 205 d, and ADG (P < 0.001). Male calves had a longer gestation length (284 d) when compared with female calves (283 d). Males were heavier than females at birth and at 205 d, and grew faster. Sire breed effects can be optimized by selection and use of appropriate crossbreeding systems.
Kim, Yong Woo; Lee, Eun Ji; Kim, Tae-Woo; Kim, Mijin; Kim, Hyunjoong
2014-07-01
To investigate whether the rate of retinal nerve fiber layer (RNFL) thinning differs according to the microstructure of β-zone parapapillary atrophy (PPA) as evaluated by spectral-domain (SD) optical coherence tomography (OCT) in primary open-angle glaucoma (POAG). Prospective, observational, comparative study. A total of 195 eyes with POAG that had been evaluated by serial SD-OCT RNFL thickness measurements for ≥ 2 years. On the basis of the extent of Bruch's membrane (BM) within the β-zone PPA (area without retinal pigment epithelium [RPE]), as shown in the infrared fundus images, PPA was divided into PPA+BM (PPA with intact BM) and PPA-BM (PPA devoid of BM). Eyes were categorized into group A (having PPA+BM only, n=64), group B (having both PPA+BM and PPA-BM, n=58), group C (having PPA-BM only, n=32), and group D (without β-zone PPA, n=41). The rate of progressive OCT RNFL thinning was determined by linear regression and compared between groups. Factors influencing the rate of RNFL thinning were evaluated, including age, sex, follow-up duration, history of filtering surgery, baseline RNFL thickness, baseline intraocular pressure (IOP), mean IOP and IOP fluctuation during follow-up, PPA types, baseline PPA width, PPA width increase, axial length (AXL), central corneal thickness, and visual field mean deviation (MD). Rate of thinning of OCT RNFL thicknesses over time. Patients in groups B and C were significantly younger and more myopic, and had a greater AXL, than those in groups A and D (all P<0.001). The rate of global RNFL thinning was significantly faster in group A (-1.66 ± 2.94 μm/year) than in the other groups (group B, -0.87 ± 1.28 μm/year; group C, 0.20 ± 1.86 μm/year; group D, -0.28 ± 1.74 μm/year; P = 0.001). Multivariate regression showed a significant association of shorter follow-up period (P = 0.016), greater baseline global RNFL thickness (P = 0.035), type of β-zone PPA (group A, P = 0.023), and greater baseline PPA+BM width (P = 0.034) with a faster rate of RNFL thinning. The rate of RNFL thinning differed according to the microstructure of β-zone PPA. It was faster for eyes with β-zone PPA with intact BM than for eyes without β-zone PPA or with β-zone PPA devoid of BM. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Time Management in the Operating Room: An Analysis of the Dedicated Minimally Invasive Surgery Suite
Hsiao, Kenneth C.; Machaidze, Zurab
2004-01-01
Background: Dedicated minimally invasive surgery suites are available that contain specialized equipment to facilitate endoscopic surgery. Laparoscopy performed in a general operating room is hampered by the multitude of additional equipment that must be transported into the room. The objective of this study was to compare the preparation times between procedures performed in traditional operating rooms versus dedicated minimally invasive surgery suites to see whether operating room efficiency is improved in the specialized room. Methods: The records of 50 patients who underwent laparoscopic procedures between September 2000 and April 2002 were retrospectively reviewed. Twenty-three patients underwent surgery in a general operating room and 18 patients in an minimally invasive surgery suite. Nine patients were excluded because of cystoscopic procedures undergone prior to laparoscopy. Various time points were recorded from which various time intervals were derived, such as preanesthesia time, anesthesia induction time, and total preparation time. A 2-tailed, unpaired Student t test was used for statistical analysis. Results: The mean preanesthesia time was significantly faster in the minimally invasive surgery suite (12.2 minutes) compared with that in the traditional operating room (17.8 minutes) (P=0.013). Mean anesthesia induction time in the minimally invasive surgery suite (47.5 minutes) was similar to time in the traditional operating room (45.7 minutes) (P=0.734). The average total preparation time for the minimally invasive surgery suite (59.6 minutes) was not significantly faster than that in the general operating room (63.5 minutes) (P=0.481). Conclusion: The amount of time that elapses between the patient entering the room and anesthesia induction is statically shorter in a dedicated minimally invasive surgery suite. Laparoscopic surgery is performed more efficiently in a dedicated minimally invasive surgery suite versus a traditional operating room. PMID:15554269
Facilitating surgeon understanding of complex anatomy using a three-dimensional printed model.
Cromeens, Barrett P; Ray, William C; Hoehne, Brad; Abayneh, Fikir; Adler, Brent; Besner, Gail E
2017-08-01
3-dimensional prints (3DP) anecdotally facilitate surgeon understanding of anatomy and decision-making. However, the actual benefit to surgeons or patients has not been quantified. This study investigates how surgeon understanding of complex anatomy is altered by a 3DP compared to computed tomography (CT) scan or CT + digital reconstruction (CT + DR). Key anatomic features were segmented from a CT-abdomen/pelvis of pygopagus twins to build a DR and printed in color on a 3D printer. Pediatric surgery trainees and attendings (n = 21) were tested regarding anatomy identification and their understanding of point-to-point distances, scale, and shape. There was no difference between media regarding point-to-point distances. The 3DP led to an increased number of correct answers for questions of scale and shape compared to CT (P < 0.05). CT + DR performance was intermediate but not statistically different from 3DP or CT. Identification of anatomy was inconsistent between media; however, answers were significantly closer to correct when using the 3DP. Participants completed the test faster with the 3DP (6.6 ± 0.5 min) (P < 0.05) than with CT (18.9 ± 2.5 min) or CT + 3DR (14.9 ± 1.5 min). Although point-to-point measurements were not different, 3DP increased the understanding of shape, scale, and anatomy. It enabled understanding significantly faster than other media. In difficult surgical cases with complex anatomy and a need for efficient multidisciplinary coordination, 3D printed models should be considered for surgical planning. Copyright © 2017 Elsevier Inc. All rights reserved.
Neostigmine but not sugammadex impairs upper airway dilator muscle activity and breathing
Eikermann, M.; Zaremba, S.; Malhotra, A.; Jordan, A. S.; Rosow, C.; Chamberlin, N. L.
2008-01-01
Background Cholinesterase inhibitor-based reversal agents, given in the absence of neuromuscular block, evoke a partial upper airway obstruction by decreasing skeletal upper airway muscle function. Sugammadex reverses neuromuscular block by encapsulating rocuronium. However, its effects on upper airway integrity and breathing are unknown. Methods Fifty-one adult male rats were anaesthetized with isoflurane, tracheostomized, and a femoral artery and vein were cannulated. First, we compared the efficacy of sugammadex 15 mg kg−1 and neostigmine 0.06 mg kg−1 to reverse respiratory effects of rocuronium-induced partial paralysis [train-of-four ratio (T4/T1)=0.5]. Subsequently, we compared the safety of sugammadex and neostigmine given after recovery of the T4/T1 to 1, by measuring phasic genioglossus activity and breathing. Results During partial paralysis (T4/T1=0.5), time to recovery of minute volume to baseline values was 10.9 (2), 75.8 (18), and 153 (54) s with sugammadex, neostigmine, and placebo, respectively (sugammadex was significantly faster than neostigmine and placebo, P<0.05). Recovery of T4/T1 was also faster for sugammadex than neostigmine and placebo. Neostigmine administration after complete recovery of T4/T1 decreased upper airway dilator muscle activity to 64 (30)% of baseline and decreased tidal volume (P<0.05 for both variables), whereas sugammadex had no effect on either variable. Conclusions In contrast to neostigmine, which significantly impairs upper airway dilator muscle activity when given after recovery from neuromuscular block, a reversal dose of sugammadex given under the same conditions does not affect genioglossus muscle activity and normal breathing. Human studies will be required to evaluate the clinical relevance of our findings. PMID:18559352
Satyamitra, Merriline; Kumar, Vidya P.; Biswas, Shukla; Cary, Lynnette; Dickson, Leonora; Venkataraman, Srinivasan; Ghosh, Sanchita P.
2017-01-01
Filgrastim (Neupogen®, granulocyte-colony stimulating factor) is among the few countermeasures recommended for management of patients in the event of lethal total-body irradiation. Despite the plethora of studies using filgrastim as a radiation countermeasure, relatively little is known about the optimal dose schedule of filgrastim to mitigate radiation lethality. We evaluated the efficacy of filgrastim in improving 30-day survival of CD2F1 mice irradiated with a lethal dose (LD70/30) in the AFRRI cobalt-60 facility. We tested different schedules of 1, 3, 5,10 or 16 once-daily injections of filgrastim initiated one day after irradiation. Time optimization studies with filgrastim treatment were also performed, beginning 6–48 h postirradiation. Maximum survival was observed with 3 daily doses of 0.17 mg/kg filgrastim. Survival efficacy of the 3-day treatment was compared against the conventional 16-day filgrastim treatment after irradiation in four mouse strains with varying radiation sensitivities: C3H/HeN, C57BL/6, B6C3F1 and CD2F1. Blood indices, bone marrow histopathology and colony forming unit assays were also evaluated. Filgrastim significantly increased 30-day survival (P < 0.001) with a 3-day treatment compared to 16-day treatment. Filgrastim did not prevent cytopenia nadirs, but facilitated faster recovery of white blood cells, neutrophils, red blood cells, platelets, lymphocytes and hematocrits in all four strains. Accelerated hematopoietic recovery was also reflected in faster bone marrow reconstitution and significant increase in hematopoietic progenitors (P < 0.001) in all four mouse strains. These data indicate that prompt and abbreviated filgrastim treatment has potential benefit for triage in the event of a radiological incident for treating acute hematopoietic syndrome. PMID:28362168
Effects of Speaking Rate on Word Recognition in Parkinson’s Disease and Normal Aging
Forrest, Karen; Nygaard, Lynne; Pisoni, David B.; Siemers, Eric
2011-01-01
Current theories of basal ganglia function emphasize their role in the integration of sensory information into motor activities, particularly in the control of movement timing. People with basal ganglia disorders such as Parkinson’s disease exhibit poor temporal control of movements, in general and articulation in particular, as demonstrated by irregular speaking rate, reduced stress contrasts, and reduced movement durations and velocities. Previous research has implicated sensory deficits as contributory factors in limb movement control in patients with Parkinson’s disease; however, the relation between sensory deficits and speech-movement abnormalities has not been documented. In the present study, the existence of perceptual processing difficulties of speaking rate was investigated in subjects with Parkinsonian dysarthria (PD). Comparisons in perception were made between subjects with PD, neurologically normal geriatrics (GN) and neurologically normal young adults (YN) for accuracy in identification of words presented at different speaking rates. We hypothesized that word-identification scores would be lower for PD and GN subjects compared to the YN subjects, an effect that was supported by the data. We also expected that there would be differences between the GN and PD subjects in their accuracy of word identification at a faster speaking rate, an hypothesis that was not supported by the data. Rather, GN and PD subjects differed in identification scores for words spoken at a slow rate. PD subjects who had faster habitual speaking rates (HSR) had significantly lower word-identification scores in the slow compared to conversational rate conditions, a relation that was significant r = +0.64). These data suggest the need to consider perceptual deficits as an additional factor that contributes to rate variations in PD speech. PMID:21637728
Algorithms of GPU-enabled reactive force field (ReaxFF) molecular dynamics.
Zheng, Mo; Li, Xiaoxia; Guo, Li
2013-04-01
Reactive force field (ReaxFF), a recent and novel bond order potential, allows for reactive molecular dynamics (ReaxFF MD) simulations for modeling larger and more complex molecular systems involving chemical reactions when compared with computation intensive quantum mechanical methods. However, ReaxFF MD can be approximately 10-50 times slower than classical MD due to its explicit modeling of bond forming and breaking, the dynamic charge equilibration at each time-step, and its one order smaller time-step than the classical MD, all of which pose significant computational challenges in simulation capability to reach spatio-temporal scales of nanometers and nanoseconds. The very recent advances of graphics processing unit (GPU) provide not only highly favorable performance for GPU enabled MD programs compared with CPU implementations but also an opportunity to manage with the computing power and memory demanding nature imposed on computer hardware by ReaxFF MD. In this paper, we present the algorithms of GMD-Reax, the first GPU enabled ReaxFF MD program with significantly improved performance surpassing CPU implementations on desktop workstations. The performance of GMD-Reax has been benchmarked on a PC equipped with a NVIDIA C2050 GPU for coal pyrolysis simulation systems with atoms ranging from 1378 to 27,283. GMD-Reax achieved speedups as high as 12 times faster than Duin et al.'s FORTRAN codes in Lammps on 8 CPU cores and 6 times faster than the Lammps' C codes based on PuReMD in terms of the simulation time per time-step averaged over 100 steps. GMD-Reax could be used as a new and efficient computational tool for exploiting very complex molecular reactions via ReaxFF MD simulation on desktop workstations. Copyright © 2013 Elsevier Inc. All rights reserved.
Sharma, Manisha; Chandramouli, Kaushik; Curley, Louise; Pontre, Beau; Reilly, Keryn; Munro, Jacob; Hill, Andrew; Young, Simon; Svirskis, Darren
2018-06-01
Sustained lidocaine release via a thermoresponsive poloxamer-based in situ gelling system has the potential to alleviate pain following knee arthroplasty. A previously developed formulation showed a promising drug release profile in synthetic phosphate-buffered saline (PBS). To support the translation of this formulation, ex vivo characterisation was warranted. This study therefore aimed (1) to modify the previously developed formulation to reduce the burst release, (2) to compare the release behaviour into ex vivo human intra-articular fluid (IAF) and PBS and (3) to determine the formulation spread in an ex vivo human knee using magnetic resonance imaging (MRI). All formulations provided sustained release out to 72 h; polyvinyl pyrrolidone was the most effective additive yielding a small yet significant decrease (p < 0.05) in the burst release. Release of lidocaine from the formulation occurred significantly faster into IAF compared to PBS (1.4 times greater release in the first 24 h), correlating with faster rates of gel erosion in IAF. Injection was easily achieved through a 21-gauge (G) needle into the synovial space of a human cadaveric knee, and MRI scans revealed effective spreading of the formulation throughout the joint cavity. The pattern of spread is promising for the drug to reach the widespread nerve endings in the joint capsule; the effect of this spread on release in an in vivo setting will be the subject of future studies. The demonstrated properties indicate that the in situ gelling formulation has the potential to be used clinically to treat post-operative pain following knee arthroplasty.
Bun, Sok-Sithikun; Ayari, Anis; Latcu, Decebal Gabriel; Errahmouni, Abdelkarim; Saoudi, Nadir
2017-07-01
Remote magnetic navigation (RMN) and contact force (CF) sensing catheters are available technologies for radiofrequency (RF) catheter ablation of atrial fibrillation (AF). Our purpose was to compare time to electrogram (EGM) modification suggesting transmural lesions between RMN and CF-guided AF ablation. A total of 1,008 RF applications were analyzed in 21 patients undergoing RMN (n = 11) or CF-guided ablation (n = 10) for paroxysmal AF. All procedures were performed in sinus rhythm during general anesthesia. Time to EGM modification was measured until transmurality criteria were fulfilled: (1) complete disappearance of R if initial QR morphology; (2) diminution > 75% of R if initial QRS morphology; (3) complete disappearance of R' of initial RSR' morphology. Impedance drop as well as force time integral (FTI) were also assessed for each application. Mean CF at the beginning of each RF application in the CF group was 11 ± 2 g and mean FTI per application was 488 ± 163 gs. Time to EGM modification was significantly shorter in the RMN group (4.52 ± 0.1 seconds vs. 5.6 ± 0.09 seconds; P < 0.00001). There was no significant difference between other procedural parameters. Remote magnetic AF ablation is associated with faster EGM modification suggesting transmurality than optimized CF and FTI-guided catheter ablation. © 2017 Wiley Periodicals, Inc.
A female advantage in the serial production of non-representational learned gestures.
Chipman, Karen; Hampson, Elizabeth
2006-01-01
Clinical research has demonstrated a sex difference in the neuroanatomical organization of the limb praxis system. To test for a corresponding sex difference in the functioning of this system, we compared healthy men and women on a gesture production task modeled after those used in apraxia research. In two separate studies, participants were taught to perform nine non-representational gestures in response to computer-generated color cues. After extensive practice with the gestures, the color cues were placed on a timer and presented in randomized sequences at progressively faster speeds. A detailed videotape analysis revealed that women in both studies committed significantly fewer 'praxic' errors than men (i.e., errors that resembled those seen in limb apraxia). This was true during both the untimed practice trials and the speeded trials of the task, despite equivalent numbers of errors between the sexes in the 'non-praxic' (i.e., executory) error categories. Women in both studies also performed the task at significantly faster speeds than men. This finding was not accounted for by a female advantage in extraneous elements of the task, i.e., speed of color processing, associative retrieval, or motor execution. Together, the two studies provide convergent support for a female advantage in the efficiency of forelimb gesture production. They are consistent with emerging evidence of a sex difference in the anatomical organization of the praxis system.
Yamaguchi, Shohei; Konishi, Kozo; Yasunaga, Takefumi; Yoshida, Daisuke; Kinjo, Nao; Kobayashi, Kiichiro; Ieiri, Satoshi; Okazaki, Ken; Nakashima, Hideaki; Tanoue, Kazuo; Maehara, Yoshihiko; Hashizume, Makoto
2007-12-01
This study was carried out to investigate whether eye-hand coordination skill on a virtual reality laparoscopic surgical simulator (the LAP Mentor) was able to differentiate among subjects with different laparoscopic experience and thus confirm its construct validity. A total of 31 surgeons, who were all right-handed, were divided into the following two groups according to their experience as an operator in laparoscopic surgery: experienced surgeons (more than 50 laparoscopic procedures) and novice surgeons (fewer than 10 laparoscopic procedures). The subjects were tested using the eye-hand coordination task of the LAP Mentor, and performance was compared between the two groups. Assessment of the laparoscopic skills was based on parameters measured by the simulator. The experienced surgeons completed the task significantly faster than the novice surgeons. The experienced surgeons also achieved a lower number of movements (NOM), better economy of movement (EOM) and faster average speed of the left instrument than the novice surgeons, whereas there were no significant differences between the two groups for the NOM, EOM and average speed of the right instrument. Eye-hand coordination skill of the nondominant hand, but not the dominant hand, measured using the LAP Mentor was able to differentiate between subjects with different laparoscopic experience. This study also provides evidence of construct validity for eye-hand coordination skill on the LAP Mentor.
Speed of response in ultrabrief and brief pulse width right unilateral ECT.
Loo, Colleen K; Garfield, Joshua B B; Katalinic, Natalie; Schweitzer, Isaac; Hadzi-Pavlovic, Dusan
2013-05-01
Ultrabrief pulse width stimulation electroconvulsive therapy (ECT) results in less cognitive side-effects than brief pulse ECT, but recent work suggests that more treatment sessions may be required to achieve similar efficacy. In this retrospective analysis of subjects pooled from three research studies, time to improvement was analysed in 150 depressed subjects who received right unilateral ECT with a brief pulse width (at five times seizure threshold) or ultrabrief pulse width (at six times seizure threshold). Multivariate Cox regression analyses compared the number of treatments required for 50% reduction in depression scores (i.e. speed of response) in these two samples. The analyses controlled for clinical, demographic and treatment variables that differed between the samples or that were found to be significant predictors of speed of response in univariate analyses. In the multivariate analysis, older age predicted faster speed of response. There was a non-significant trend for faster time to 50% improvement with brief pulse ECT (p = 0.067). Remission rates were higher after brief pulse ECT than ultrabrief pulse ECT (p = 0.007) but response rates were similar. This study, the largest of its kind reported to date, suggests that fewer treatments may be needed to attain response with brief than ultrabrief pulse ECT and that remission rates are higher with brief pulse ECT. Further research with a larger randomized and blinded study is recommended.
Thistle, Jennifer J; Wilkinson, Krista
2017-09-01
Children whose speech does not meet their communication needs often benefit from augmentative and alternative communication (AAC). The design of an AAC display may influence the child's ability to communicate effectively. The current study examined how symbol background color cues and symbol arrangement affected construction of multi-symbol messages using line-drawing symbols, by young children with typical development. Participants (N = 52) heard a spoken phrase matching a photograph and selected line drawings within a 4 × 4 array. Friedman two-way ANOVAs evaluated speed and accuracy of multi-symbol message construction under four conditions in which the background color and arrangement of symbols was manipulated. Participants demonstrated significantly faster response times when symbols were arranged by word-class category compared to no symbol arrangement. The majority of children responded faster when symbols had white backgrounds, but this effect failed to reach statistical significance. This study provides preliminary evidence suggesting the importance of symbol arrangement for young children. The findings highlight the need for caution when incorporating background color on displays for young children. Future research is needed to examine the effect of visual cues on children who use AAC and consider additional factors that could influence efficacy of symbol arrangement and background color use.
Single session of Nd:YAG laser intracanal irradiation neutralizes endotoxin in dental root dentin
NASA Astrophysics Data System (ADS)
Archilla, José R. F.; Moreira, Maria S. N. A.; Miyagi, Sueli P. H.; Bombana, Antônio C.; Gutknecht, Norbert; Marques, Márcia M.
2012-11-01
Endotoxins released in the dental root by Gram-negative microorganisms can be neutralized by calcium hydroxide, when this medication is applied inside the root canal for at least seven days. However, several clinical situations demand faster root canal decontamination. Thus, for faster endotoxin neutralization, endodontists are seeking additional treatments. The in vitro study tested whether or not intracanal Nd:YAG laser irradiation would be able to neutralize endotoxin within the human dental root canal in a single session. Twenty-four human teeth with one root were mounted between two chambers. After conventional endodontic treatment, root canals were contaminated with Escherichia coli endotoxin. Then they were irradiated or not (controls) in contact mode with an Nd:YAG laser (1.5 W, 15 Hz, 100 mJ and pulse fluency of 124 J/cm2). The endotoxin activity was measured using the limulus lysate technique and data were statistically compared (p≤0.05). The concentration of active endotoxin measured in the negative control group was significantly lower than that of the positive control group (p=0.04). The concentrations of endotoxin in both irradiated groups were significantly lower than that of the positive control group (p=0.027) and similar to that of negative control group (p=0.20). A single session of intracanal Nd:YAG laser irradiation is able to neutralize endotoxin in the dental root tissues.
Single session of Nd:YAG laser intracanal irradiation neutralizes endotoxin in dental root dentin.
Archilla, José R F; Moreira, Maria S N A; Miyagi, Sueli P H; Bombana, Antônio C; Gutknecht, Norbert; Marques, Márcia M
2012-11-01
Endotoxins released in the dental root by Gram-negative microorganisms can be neutralized by calcium hydroxide, when this medication is applied inside the root canal for at least seven days. However, several clinical situations demand faster root canal decontamination. Thus, for faster endotoxin neutralization, endodontists are seeking additional treatments. The in vitro study tested whether or not intracanal Nd:YAG laser irradiation would be able to neutralize endotoxin within the human dental root canal in a single session. Twenty-four human teeth with one root were mounted between two chambers. After conventional endodontic treatment, root canals were contaminated with Escherichia coli endotoxin. Then they were irradiated or not (controls) in contact mode with an Nd:YAG laser (1.5 W, 15 Hz, 100 mJ and pulse fluency of 124 J/cm2). The endotoxin activity was measured using the limulus lysate technique and data were statistically compared (p≤0.05). The concentration of active endotoxin measured in the negative control group was significantly lower than that of the positive control group (p=0.04). The concentrations of endotoxin in both irradiated groups were significantly lower than that of the positive control group (p=0.027) and similar to that of negative control group (p=0.20). A single session of intracanal Nd:YAG laser irradiation is able to neutralize endotoxin in the dental root tissues.
Sutton, J A; Gillin, W P; Grattan, T J; Clarke, G D; Kilminster, S G
2002-01-01
Aims To discover whether a new infra-red laser method could detect a change in pain threshold after as mild an analgesic as paracetamol and whether an effervescent liquid formulation produced a faster onset of action than tablets. Methods This double-blind, placebo controlled randomized study used a portable, infra-red laser to measure ‘first pain’ thresholds on the nondominant forearm in 12 normal volunteers before and after 1 g of paracetamol or placebo. The mean of six recordings was determined three times before dosing, the first being used as a familiarization procedure, and 14 times after dosing. Results We detected a small (2%), statistically significant difference in pain threshold between a liquid formulation of paracetamol and placebo at 30 and 60 min (P = 0.004 and P = 0.001), but not between tablets and placebo. Liquid also increased the threshold significantly compared with tablets at 60 min (P = 0.01). Conclusions To detect such a small increase in pain threshold requires a highly consistent measure and the coefficient of variation was 2% for the study overall, surprisingly low for a subjective phenomenon. The reasons for this include minimizing reflectance by blacking the skin, using a nonhairy site, averaging six data points at each sample time and controlling closely the ambient conditions and the subjects’ preparation for studies. PMID:11849194
Mihalik, Jason P; Libby, Jeremiah J; Battaglini, Claudio L; McMurray, Robert G
2008-01-01
The purpose of this study was to determine whether there were differences in vertical jump height and lower body power production gains between complex and compound training programs. A secondary purpose was to determine whether differences in gains were observed at a faster rate between complex and compound training programs. Thirty-one college-aged club volleyball players (11 men and 20 women) were assigned into either a complex training group or a compound training group based on gender and pre-training performance measures. Both groups trained twice per week for 4 weeks. Work was equated between the 2 groups. Complex training alternated between resistance and plyometric exercises on each training day; whereas, compound training consisted of resistance training on one day and plyometric training on the other. Our analyses showed significant improvements in vertical jump height in both training groups after only 3 weeks of training (P < 0.0001); vertical jump height increased by approximately 5% and 9% in the complex and compound training groups, respectively. However, neither group improved significantly better than the other, nor did either group experience faster gains in vertical leap or power output. The results of this study suggest that performing a minimum of 3 weeks of either complex or compound training is effective for improving vertical jump height and power output; thus, coaches should choose the program which best suits their training schedules.
Buccal acetaminophen provides fast analgesia: two randomized clinical trials in healthy volunteers
Pickering, Gisèle; Macian, Nicolas; Libert, Frédéric; Cardot, J Michel; Coissard, Séverine; Perovitch, Philippe; Maury, Marc; Dubray, Claude
2014-01-01
Background Acetaminophen (APAP) by oral or intravenous (iv) routes is used for mild to moderate pain but may take time to be effective. When fast relief is required and/or oral or iv routes are not available because of the patient’s condition, the transmucosal route may be an alternative. Methodology A new transmucosal/buccal (b) pharmaceutical form of APAP dissolved in 50% wt alcohol is compared with other routes of administration. Two consecutive randomized, crossover, double-blind clinical trials (CT1: NCT00982215 and CT2: NCT01206985) included 16 healthy volunteers. CT1 compared the pharmacology of 250 mg bAPAP with 1 g iv APAP. CT2 compared the pharmacodynamics of 125 mg bAPAP with 1 g iv and 125 mg sublingual (s) APAP. Mechanical pain thresholds are recorded in response to mechanical stimuli applied on the forearm several times during 120 minutes. The objective is to compare the time of onset of antinociception and the antinociception (area under the curve) between the routes of administration with analysis of variance (significance P<0.05). Results bAPAP has a faster time of antinociception onset (15 minutes, P<0.01) and greater antinociception at 50 minutes (P<0.01, CT1) and 30 minutes (P<0.01, CT2) than ivAPAP and sAPAP. All routes are similar after 50 minutes. Conclusion bAPAP has a faster antinociceptive action in healthy volunteers. This attractive alternative to other routes would be useful in situations where oral or iv routes are not available. This finding must now be confirmed in patients suffering from acute pain of mild and moderate intensity. PMID:25302017
Takada, Kenta; Kumada, Hiroaki; Liem, Peng Hong; Sakurai, Hideyuki; Sakae, Takeji
2016-12-01
We simulated the effect of patient displacement on organ doses in boron neutron capture therapy (BNCT). In addition, we developed a faster calculation algorithm (NCT high-speed) to simulate irradiation more efficiently. We simulated dose evaluation for the standard irradiation position (reference position) using a head phantom. Cases were assumed where the patient body is shifted in lateral directions compared to the reference position, as well as in the direction away from the irradiation aperture. For three groups of neutron (thermal, epithermal, and fast), flux distribution using NCT high-speed with a voxelized homogeneous phantom was calculated. The three groups of neutron fluxes were calculated for the same conditions with Monte Carlo code. These calculated results were compared. In the evaluations of body movements, there were no significant differences even with shifting up to 9mm in the lateral directions. However, the dose decreased by about 10% with shifts of 9mm in a direction away from the irradiation aperture. When comparing both calculations in the phantom surface up to 3cm, the maximum differences between the fluxes calculated by NCT high-speed with those calculated by Monte Carlo code for thermal neutrons and epithermal neutrons were 10% and 18%, respectively. The time required for NCT high-speed code was about 1/10th compared to Monte Carlo calculation. In the evaluation, the longitudinal displacement has a considerable effect on the organ doses. We also achieved faster calculation of depth distribution of thermal neutron flux using NCT high-speed calculation code. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Stauder, Udo; Enginee, Diplom; Elton, Hina; Penfornis, Alfred; Edelman, Steve
2014-01-01
Glucagon-like peptide-1 (GLP-1) receptor agonists are a relatively recent addition to the treatment options for type 2 diabetes mellitus (T2DM) and are administered using prefilled pen devices. In this open-label task and interview-based pilot study, 3 GLP-1 receptor agonist pen devices-exenatide (Byetta ® , Bristol-Myers Squibb/AstraZeneca), liraglutide (Victoza ® , Novo Nordisk), and lixisenatide (Lyxumia ® , Sanofi-Aventis)-were comparatively assessed in a randomized order in 30 participants with T2DM for ease of use, using a series of key performance measures (time taken to complete a series of tasks, number of user errors [successful performance], and user satisfaction rating). Linear and logistic regression analysis was conducted for the lixisenatide and liraglutide pens versus the exenatide pen. Participants' mean age was 60 years; 27% and 20% of the participants had visual impairments and reduced manual dexterity, respectively. Tasks were completed faster (P < .001) and with higher successful performance (P = .001) with the lixisenatide pen than with the exenatide pen, whereas the liraglutide pen was not statistically significant versus the exenatide pen on these parameters. Overall, user satisfaction was statistically higher for the lixisenatide and liraglutide pens versus the exenatide pen (P < .001 for both). Lixisenatide and liraglutide pens are associated with higher user satisfaction compared with the exenatide pen. In addition, the lixisenatide pen is faster and results in fewer errors than its comparator (exenatide). The lixisenatide pen may therefore be a suitable choice for patients with T2DM, including older and pen device-naïve patients, and those with visual impairments and reduced manual dexterity. © 2014 Diabetes Technology Society.
Comparative Assessment of Lixisenatide, Exenatide, and Liraglutide Pen Devices
Enginee, Diplom; Elton, Hina; Penfornis, Alfred; Edelman, Steve
2014-01-01
Background: Glucagon-like peptide-1 (GLP-1) receptor agonists are a relatively recent addition to the treatment options for type 2 diabetes mellitus (T2DM) and are administered using prefilled pen devices. Method: In this open-label task and interview-based pilot study, 3 GLP-1 receptor agonist pen devices—exenatide (Byetta®, Bristol-Myers Squibb/AstraZeneca), liraglutide (Victoza®, Novo Nordisk), and lixisenatide (Lyxumia®, Sanofi-Aventis)—were comparatively assessed in a randomized order in 30 participants with T2DM for ease of use, using a series of key performance measures (time taken to complete a series of tasks, number of user errors [successful performance], and user satisfaction rating). Linear and logistic regression analysis was conducted for the lixisenatide and liraglutide pens versus the exenatide pen. Participants’ mean age was 60 years; 27% and 20% of the participants had visual impairments and reduced manual dexterity, respectively. Results: Tasks were completed faster (P < .001) and with higher successful performance (P = .001) with the lixisenatide pen than with the exenatide pen, whereas the liraglutide pen was not statistically significant versus the exenatide pen on these parameters. Overall, user satisfaction was statistically higher for the lixisenatide and liraglutide pens versus the exenatide pen (P < .001 for both). Conclusions: Lixisenatide and liraglutide pens are associated with higher user satisfaction compared with the exenatide pen. In addition, the lixisenatide pen is faster and results in fewer errors than its comparator (exenatide). The lixisenatide pen may therefore be a suitable choice for patients with T2DM, including older and pen device-naïve patients, and those with visual impairments and reduced manual dexterity. PMID:24876548
Economopoulos, Kostas J.; Milewski, Matthew D.; Hanks, John B.; Hart, Joseph M.; Diduch, David R.
2013-01-01
Background: The minimal repair technique for sports hernias repairs only the weak area of the posterior abdominal wall along with decompressing the genitofemoral nerve. This technique has been shown to return athletes to competition rapidly. This study compares the clinical outcomes of the minimal repair technique with the traditional modified Bassini repair. Hypothesis: Athletes undergoing the minimal repair technique for a sports hernia would return to play more rapidly compared with athletes undergoing the traditional modified Bassini repair. Methods: A retrospective study of 28 patients who underwent sports hernia repair at the authors’ institution was performed. Fourteen patients underwent the modified Bassini repair, and a second group of 14 patients underwent the minimal repair technique. The 2 groups were compared with respect to time to return to sport, return to original level of competition, and clinical outcomes. Results: Patients in the minimal repair group returned to sports at a median of 5.6 weeks (range, 4-8 weeks), which was significantly faster compared with the modified Bassini repair group, with a median return of 25.8 weeks (range, 4-112 weeks; P = 0.002). Thirteen of 14 patients in the minimal repair group returned to sports at their previous level, while 9 of 14 patients in the Bassini group were able to return to their previous level of sport (P = 0.01). Two patients in each group had recurrent groin pain. One patient in the minimal repair group underwent revision hernia surgery for recurrent pain, while 1 patient in the Bassini group underwent hip arthroscopy for symptomatic hip pain. Conclusion: The minimal repair technique allows athletes with sports hernias to return to play faster than patients treated with the modified Bassini. PMID:24427419
Rates of retinal nerve fiber layer thinning in glaucoma suspect eyes
Miki, Atsuya; Medeiros, Felipe A.; Weinreb, Robert N.; Jain, Sonia; He, Feng; Sharpsten, Lucie; Khachatryan, Naira; Hammel, Na’ama; Liebmann, Jeffrey M.; Girkin, Christopher A.; Sample, Pamela A.; Zangwill, Linda M.
2015-01-01
Purpose To compare the rates of retinal nerve fiber layer (RNFL) loss in patients suspect of having glaucoma who developed visual field damage (VFD) to those who did not develop VFD, and to determine whether the rate of RNFL loss can be used to predict who will develop VFD.. Design Prospective observational cohort study Participants Glaucoma suspects, defined as having glaucomatous optic neuropathy or ocular hypertension (Intraocular pressure (IOP)>21 mmHg) without repeatable VFD at baseline from the Diagnostic Innovations in Glaucoma Study, and the African Descent and Glaucoma Evaluation Study. Methods Global and quadrant RNFL thickness (RNFLT) were measured with the Spectralis spectral-domain optical coherence tomography (SD-OCT). VFD was defined as having 3 consecutive abnormal visual fields. The rate of RNFL loss in eyes developing VFD was compared with eyes not developing VFD using multivariable linear mixed-effects models. A joint longitudinal survival model utilized the estimated RNFLT slope to predict the risk of developing VFD, while adjusting for potential confounding variables. Main Outcome Measures The rate of RNFL thinning and the probability of developing VFD. Results Four hundred and fifty-four eyes of 294 glaucoma suspects were included. The average number of SD-OCT examinations was 4.6 (range, 2–9) with median follow-up time of 2.2 (0.4–4.1) years. Forty eyes (8.8%) developed VFD. The estimated mean rate of global RNFL loss was significantly faster in eyes developing VFD compared with eyes that did not (−2.02μm/year vs. −0.82μm/year, P<0.001). The joint longitudinal survival model showed that each 1μm/year faster rate of global RNFL loss corresponded to a 2.05 times higher risk of developing VFD (Hazards Ratio (HR)=2.05, 95% Confidence Interval (CI): 1.14–3.71; p=0.017). Conclusions The rate of global RNFL loss was more than twice as fast in eyes developing VFD compared with eyes that did not develop them. Joint longitudinal survival model showed that a 1μm/year faster rate of RNFLT loss corresponded to a 2.05 times higher risk of developing VFD. These results suggest that measuring the rate of SD-OCT RNFL loss may be a useful tool to help identify patients who are at a high risk of developing visual field loss. PMID:24629619
Kinematical Comparison of the 200 m Backstroke Turns between National and Regional Level Swimmers
Veiga, Santiago; Cala, Antonio; Frutos, Pablo González; Navarro, Enrique
2013-01-01
The aims of this investigation were to determine the evolution of selected turn variables during competitive backstroke races and to compare these kinematic variables between two different levels of swimmers. Sixteen national and regional level male swimmers participant in the 200 m backstroke event at the Spanish Swimming Championships in short course (25 m) were selected to analyze their turn performances. The individual distances method with two-dimensional Direct Linear Transformation (2D-DLT) algorithms was used to perform race analyses. National level swimmers presented a shorter “turn time”, a longer “distance in”, a faster “underwater velocity” and “normalized underwater velocity”, and a faster “stroking velocity” than regional level swimmers, whereas no significant differences were detected between levels for the “underwater distance”. National level swimmers maintained similar “turn times” over the event and increased “underwater velocity” and “normalized underwater velocity” in the last (seventh) turn segment, whereas regional level swimmers increased “turn time” in the last half of the race. For both national and regional level swimmers, turn “underwater distance” during the last three turns of the race was significantly shorter while no significant differences in distance into the wall occurred throughout the race. The skill level of the swimmers has an impact on the competitive backstroke turn segments. In a 200 m event, the underwater velocity should be maximized to maintain turn proficiency, whereas turn distance must be subordinated to the average velocity. Key Points The underwater turn velocity is as a critical variable related to the swimmers’ level of skill in a 200 m backstroke event. Best swimmers perform faster but no longer turn segments during a 200 m backstroke event. Best swimmers maintain their turn performance throughout the 200 m backstroke event by increasing the underwater velocity during the final part of the race. The turn distance out seems to be subordinated in order to maximize the average velocity during a 200 m backstroke event. PMID:24421733
Chang, Chiou Ling; Cho, Il Kyu; Li, Qing X
2009-02-01
Basil oil and its three major active constituents (trans-anethole, estragole, and linalool) obtained from basil (Oscimum basilicum L.) were tested on three tephritid fruit fly species [Ceratitis capitata (Wiedemann), Bactrocera dorsalis (Hendel), and Bactrocera cucurbitae (Coquillett)] for insecticidal activity. All test chemicals acted fast and showed a steep dose-response relationship. The lethal times for 90% mortality/knockdown (LT90) of the three fly species to 10% of the test chemicals were between 8 and 38 min. The toxic action of basil oil in C. capitata occurred significantly faster than in B. cucurbitae but slightly faster than in B. dorsalis. Estragole acted faster in B. dorsalis than in C. capitata and B. cucurbitae. Linalool action was faster in B. dorsalis and C. capitata than in B. cucurbitae. trans-Anethole action was similar to all three species. Methyl eugenol acted faster in C. capitata and B. cucurbitae than in B. dorsalis. When linalool was mixed with cuelure (attractant to B. cucurbitae male), its potency to the three fly species decreased as the concentration of cuelure increased. This was due to linalool hydrolysis catalyzed by acetic acid from cuelure degradation, which was confirmed by chemical analysis. When methyl eugenol (B. dorsalis male attractant) was mixed with basil oil, trans-anethole, estragole, or linalool, it did not affect the toxicity of basil oil and linalool to B. dorsalis, but it did significantly decrease the toxicity of trans-anethole and estragole. Structural similarity between methyl eugenol and trans-anethole and estragole suggests that methyl eugenol might act at a site similar to that of trans-anethole and estragole and serve as an antagonist if an action site exists. Methyl eugenol also may play a physiological role on the toxicity reduction.
Rapid assessment of forest canopy and light regime using smartphone hemispherical photography.
Bianchi, Simone; Cahalan, Christine; Hale, Sophie; Gibbons, James Michael
2017-12-01
Hemispherical photography (HP), implemented with cameras equipped with "fisheye" lenses, is a widely used method for describing forest canopies and light regimes. A promising technological advance is the availability of low-cost fisheye lenses for smartphone cameras. However, smartphone camera sensors cannot record a full hemisphere. We investigate whether smartphone HP is a cheaper and faster but still adequate operational alternative to traditional cameras for describing forest canopies and light regimes. We collected hemispherical pictures with both smartphone and traditional cameras in 223 forest sample points, across different overstory species and canopy densities. The smartphone image acquisition followed a faster and simpler protocol than that for the traditional camera. We automatically thresholded all images. We processed the traditional camera images for Canopy Openness (CO) and Site Factor estimation. For smartphone images, we took two pictures with different orientations per point and used two processing protocols: (i) we estimated and averaged total canopy gap from the two single pictures, and (ii) merging the two pictures together, we formed images closer to full hemispheres and estimated from them CO and Site Factors. We compared the same parameters obtained from different cameras and estimated generalized linear mixed models (GLMMs) between them. Total canopy gap estimated from the first processing protocol for smartphone pictures was on average significantly higher than CO estimated from traditional camera images, although with a consistent bias. Canopy Openness and Site Factors estimated from merged smartphone pictures of the second processing protocol were on average significantly higher than those from traditional cameras images, although with relatively little absolute differences and scatter. Smartphone HP is an acceptable alternative to HP using traditional cameras, providing similar results with a faster and cheaper methodology. Smartphone outputs can be directly used as they are for ecological studies, or converted with specific models for a better comparison to traditional cameras.
Tastet, Lionel; Capoulade, Romain; Clavel, Marie-Annick; Larose, Éric; Shen, Mylène; Dahou, Abdellaziz; Arsenault, Marie; Mathieu, Patrick; Bédard, Élisabeth; Dumesnil, Jean G; Tremblay, Alexe; Bossé, Yohan; Després, Jean-Pierre; Pibarot, Philippe
2017-01-01
Hypertension is highly prevalent in patients with aortic stenosis (AS) and is associated with worse outcomes. The current prospective study assessed the impact of systolic hypertension (SHPT) on the progression of aortic valve calcification (AVC) measured by multidetector computed tomography (MDCT) in patients with AS. The present analysis includes the first series of 101 patients with AS prospectively recruited in the PROGRESSA study. Patients underwent comprehensive Doppler echocardiography and MDCT exams at baseline and after 2-year follow-up. AVC and coronary artery calcification (CAC) were measured using the Agatston method. Patients with SHPT at baseline (i.e. systolic blood pressure ≥140 mmHg; n = 37, 37%) had faster 2-year AVC progression compared with those without SHPT (i.e. systolic blood pressure <140 mmHg) (AVC median [25th percentile-75th percentile]: +370 [126-824] vs. +157 [58-303] AU; P = 0.007, respectively). Similar results were obtained with the analysis of AVC progression divided by the cross-sectional area of the aortic annulus (AVC density : +96 [34-218] vs. +45 [14-82] AU/cm 2 , P = 0.01, respectively). In multivariable analysis, SHPT remained significantly associated with faster progression of AVC or AVC density (all P = 0.001). There was no significant difference between groups with respect to progression of CAC (+39 [3-199] vs. +41 [0-156] AU, P = 0.88). This prospective study shows for the first time that SHPT is associated with faster AVC progression but not with CAC progression in AS patients. These findings provide further support for the elaboration of randomized clinical trials to assess the efficacy of antihypertensive medication to slow the stenosis progression in patients with AS. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Yaffe, Robert B; Shaikhouni, Ammar; Arai, Jennifer; Inati, Sara K; Zaghloul, Kareem A
2017-04-26
Converging evidence suggests that reinstatement of neural activity underlies our ability to successfully retrieve memories. However, the temporal dynamics of reinstatement in the human cortex remain poorly understood. One possibility is that neural activity during memory retrieval, like replay of spiking neurons in the hippocampus, occurs at a faster timescale than during encoding. We tested this hypothesis in 34 participants who performed a verbal episodic memory task while we recorded high gamma (62-100 Hz) activity from subdural electrodes implanted for seizure monitoring. We show that reinstatement of distributed patterns of high gamma activity occurs faster than during encoding. Using a time-warping algorithm, we quantify the timescale of the reinstatement and identify brain regions that show significant timescale differences between encoding and retrieval. Our data suggest that temporally compressed reinstatement of cortical activity is a feature of cued memory retrieval. SIGNIFICANCE STATEMENT We show that cued memory retrieval reinstates neural activity on a faster timescale than was present during encoding. Our data therefore provide a link between reinstatement of neural activity in the cortex and spontaneous replay of cortical and hippocampal spiking activity, which also exhibits temporal compression, and suggest that temporal compression may be a universal feature of memory retrieval. Copyright © 2017 the authors 0270-6474/17/374472-09$15.00/0.
Self-relevant beauty evaluation: Evidence from an event-related potentials study.
Kong, Fanchang; Zhang, Yan; Tian, Yuan; Fan, Cuiying; Zhou, Zongkui
2015-03-01
This study examines the electrophysiological correlates of beauty evaluation when participants performed the self-reference task. About 13 (7 men, 6 women) undergraduates participated in the experiment using event-related potentials. Results showed that the response to self-relevant information was faster compared to other-relevant information and no significant differences for self-relevant relative to mother-relevant information were observed. Both physical and interior beauty words for self-relevant information showed an enhanced late positive component as compared to other-relevant information. Physical beauty for self-relevant information yielded a larger late positive component in contrast to mother-relevant information but not for interior beauty. This study indicates that beauty is specific to the person who judges it though an individual and one's mother may hold similar views of interior beauty.
Attia, Khalid A M; Nassar, Mohammed W I; El-Zeiny, Mohamed B; Serag, Ahmed
2017-01-05
For the first time, a new variable selection method based on swarm intelligence namely firefly algorithm is coupled with three different multivariate calibration models namely, concentration residual augmented classical least squares, artificial neural network and support vector regression in UV spectral data. A comparative study between the firefly algorithm and the well-known genetic algorithm was developed. The discussion revealed the superiority of using this new powerful algorithm over the well-known genetic algorithm. Moreover, different statistical tests were performed and no significant differences were found between all the models regarding their predictabilities. This ensures that simpler and faster models were obtained without any deterioration of the quality of the calibration. Copyright © 2016 Elsevier B.V. All rights reserved.
PconsD: ultra rapid, accurate model quality assessment for protein structure prediction.
Skwark, Marcin J; Elofsson, Arne
2013-07-15
Clustering methods are often needed for accurately assessing the quality of modeled protein structures. Recent blind evaluation of quality assessment methods in CASP10 showed that there is little difference between many different methods as far as ranking models and selecting best model are concerned. When comparing many models, the computational cost of the model comparison can become significant. Here, we present PconsD, a fast, stream-computing method for distance-driven model quality assessment that runs on consumer hardware. PconsD is at least one order of magnitude faster than other methods of comparable accuracy. The source code for PconsD is freely available at http://d.pcons.net/. Supplementary benchmarking data are also available there. arne@bioinfo.se Supplementary data are available at Bioinformatics online.
Morse, J; Terrasini, N; Wehbe, M; Philippona, C; Zaouter, C; Cyr, S; Hemmerling, T M
2014-06-01
This study focuses on a recently developed robotic nerve block system and its impact on learning regional anaesthesia skills. We compared success rates, learning curves, performance times, and inter-subject performance variability of robot-assisted vs manual ultrasound (US)-guided nerve block needle guidance. The hypothesis of this study is that robot assistance will result in faster skill acquisition than manual needle guidance. Five co-authors with different experience with nerve blocks and the robotic system performed both manual and robot-assisted, US-guided nerve blocks on two different nerves of a nerve phantom. Ten trials were performed for each of the four procedures. Time taken to move from a shared starting position till the needle was inserted into the target nerve was defined as the performance time. A successful block was defined as the insertion of the needle into the target nerve. Average performance times were compared using analysis of variance. P<0.05 was considered significant. Data presented as mean (standard deviation). All blocks were successful. There were significant differences in performance times between co-authors to perform the manual blocks, either superficial (P=0.001) or profound (P=0.0001); no statistical difference between co-authors was noted for the robot-assisted blocks. Linear regression indicated that the average decrease in time between consecutive trials for robot-assisted blocks of 1.8 (1.6) s was significantly (P=0.007) greater than the decrease for manual blocks of 0.3 (0.3) s. Robot assistance of nerve blocks allows for faster learning of needle guidance over manual positioning and reduces inter-subject performance variability. © The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Galletto Pregliasco, A; Collin, A; Guéguen, A; Metten, M A; Aboab, J; Deschamps, R; Gout, O; Duron, L; Sadik, J C; Savatovsky, J; Lecler, A
2018-06-07
MR imaging is the key examination in the follow-up of patients with MS, by identification of new high-signal T2 brain lesions. However, identifying new lesions when scrolling through 2 follow-up MR images can be difficult and time-consuming. Our aim was to compare an automated coregistration-fusion reading approach with the standard approach by identifying new high-signal T2 brain lesions in patients with multiple sclerosis during follow-up MR imaging. This prospective monocenter study included 94 patients (mean age, 38.9 years) treated for MS with dimethyl fumarate from January 2014 to August 2016. One senior neuroradiologist and 1 junior radiologist checked for new high-signal T2 brain lesions, independently analyzing blinded image datasets with automated coregistration-fusion or the standard scroll-through approach with a 3-week delay between the 2 readings. A consensus reading with a second senior neuroradiologist served as a criterion standard for analyses. A Poisson regression and logistic and γ regressions were used to compare the 2 methods. Intra- and interobserver agreement was assessed by the κ coefficient. There were significantly more new high-signal T2 lesions per patient detected with the coregistration-fusion method (7 versus 4, P < .001). The coregistration-fusion method detected significantly more patients with at least 1 new high-signal T2 lesion (59% versus 46%, P = .02) and was associated with significantly faster overall reading time (86 seconds faster, P < .001) and higher reader confidence (91% versus 40%, P < 1 × 10 -4 ). Inter- and intraobserver agreement was excellent for counting new high-signal T2 lesions. Our study showed that an automated coregistration-fusion method was more sensitive for detecting new high-signal T2 lesions in patients with MS and reducing reading time. This method could help to improve follow-up care. © 2018 by American Journal of Neuroradiology.
Cha, Dong Ik; Lee, Min Woo; Kim, Ah Yeong; Kang, Tae Wook; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Seo, Bong Koo; Kim, Kyunga
2017-11-01
Background A major drawback of conventional manual image fusion is that the process may be complex, especially for less-experienced operators. Recently, two automatic image fusion techniques called Positioning and Sweeping auto-registration have been developed. Purpose To compare the accuracy and required time for image fusion of real-time ultrasonography (US) and computed tomography (CT) images between Positioning and Sweeping auto-registration. Material and Methods Eighteen consecutive patients referred for planning US for radiofrequency ablation or biopsy for focal hepatic lesions were enrolled. Image fusion using both auto-registration methods was performed for each patient. Registration error, time required for image fusion, and number of point locks used were compared using the Wilcoxon signed rank test. Results Image fusion was successful in all patients. Positioning auto-registration was significantly faster than Sweeping auto-registration for both initial (median, 11 s [range, 3-16 s] vs. 32 s [range, 21-38 s]; P < 0.001] and complete (median, 34.0 s [range, 26-66 s] vs. 47.5 s [range, 32-90]; P = 0.001] image fusion. Registration error of Positioning auto-registration was significantly higher for initial image fusion (median, 38.8 mm [range, 16.0-84.6 mm] vs. 18.2 mm [6.7-73.4 mm]; P = 0.029), but not for complete image fusion (median, 4.75 mm [range, 1.7-9.9 mm] vs. 5.8 mm [range, 2.0-13.0 mm]; P = 0.338]. Number of point locks required to refine the initially fused images was significantly higher with Positioning auto-registration (median, 2 [range, 2-3] vs. 1 [range, 1-2]; P = 0.012]. Conclusion Positioning auto-registration offers faster image fusion between real-time US and pre-procedural CT images than Sweeping auto-registration. The final registration error is similar between the two methods.
Why Be a Shrub? A Basic Model and Hypotheses for the Adaptive Values of a Common Growth Form
Götmark, Frank; Götmark, Elin; Jensen, Anna M.
2016-01-01
Shrubs are multi-stemmed short woody plants, more widespread than trees, important in many ecosystems, neglected in ecology compared to herbs and trees, but currently in focus due to their global expansion. We present a novel model based on scaling relationships and four hypotheses to explain the adaptive significance of shrubs, including a review of the literature with a test of one hypothesis. Our model describes advantages for a small shrub compared to a small tree with the same above-ground woody volume, based on larger cross-sectional stem area, larger area of photosynthetic tissue in bark and stem, larger vascular cambium area, larger epidermis (bark) area, and larger area for sprouting, and faster production of twigs and canopy. These components form our Hypothesis 1 that predicts higher growth rate for a small shrub than a small tree. This prediction was supported by available relevant empirical studies (14 publications). Further, a shrub will produce seeds faster than a tree (Hypothesis 2), multiple stems in shrubs insure future survival and growth if one or more stems die (Hypothesis 3), and three structural traits of short shrub stems improve survival compared to tall tree stems (Hypothesis 4)—all hypotheses have some empirical support. Multi-stemmed trees may be distinguished from shrubs by more upright stems, reducing bending moment. Improved understanding of shrubs can clarify their recent expansion on savannas, grasslands, and alpine heaths. More experiments and other empirical studies, followed by more elaborate models, are needed to understand why the shrub growth form is successful in many habitats. PMID:27507981
Silvola, Juha; Salonen, Aarre; Nieminen, Jouko; Kokki, Hannu
2011-02-01
We have compared tonsillectomy (TE) with tissue welding (TW) technology using a specially designed forceps versus conventional monopolar electrocautery to evaluate whether this new technology may improve recovery after TE. This was a single-blind, randomized clinical trial with two parallel groups. Sixty healthy adult day-surgery patients were allocated into the TW-TE group (n = 31) and the monopolar electrocautery-TE group (n = 29). We recorded intraoperative events and short- and long-term recovery for 2 weeks postoperatively. The patients and study nurses evaluating patients during recovery were blinded to the operation method used. All patients in the TW-TE group completed the study as per protocol, but in the monopolar electrocautery-TE group, there was one drop-out in the hospital and another after discharge. There was no difference in the perioperative parameters and early recovery between the two groups. After discharge, recovery was significantly faster in the TW group than in the monopolar group: (1) the duration of postoperative pain was 2 days shorter, and (2) activities of normal daily living were less affected, and (3) the need for hospital contacts after discharge, and (4) the incidence of postoperative bleeding was less in the TW group than that in the monopolar group. No patients in the TW group developed secondary bleeding versus three patients in the monopolar group requiring electrocautery to control bleeding. In conclusion; our results indicate that, TW technique may provide reduced pain, faster recovery, and fewer complications compared to electrocautery TE.
Mavratzakis, Aimee; Herbert, Cornelia; Walla, Peter
2016-01-01
In the current study, electroencephalography (EEG) was recorded simultaneously with facial electromyography (fEMG) to determine whether emotional faces and emotional scenes are processed differently at the neural level. In addition, it was investigated whether these differences can be observed at the behavioural level via spontaneous facial muscle activity. Emotional content of the stimuli did not affect early P1 activity. Emotional faces elicited enhanced amplitudes of the face-sensitive N170 component, while its counterpart, the scene-related N100, was not sensitive to emotional content of scenes. At 220-280ms, the early posterior negativity (EPN) was enhanced only slightly for fearful as compared to neutral or happy faces. However, its amplitudes were significantly enhanced during processing of scenes with positive content, particularly over the right hemisphere. Scenes of positive content also elicited enhanced spontaneous zygomatic activity from 500-750ms onwards, while happy faces elicited no such changes. Contrastingly, both fearful faces and negative scenes elicited enhanced spontaneous corrugator activity at 500-750ms after stimulus onset. However, relative to baseline EMG changes occurred earlier for faces (250ms) than for scenes (500ms) whereas for scenes activity changes were more pronounced over the whole viewing period. Taking into account all effects, the data suggests that emotional facial expressions evoke faster attentional orienting, but weaker affective neural activity and emotional behavioural responses compared to emotional scenes. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Cognitive decline following incident and preexisting diabetes mellitus in a population sample.
Rajan, Kumar B; Arvanitakis, Zoe; Lynch, Elizabeth B; McAninch, Elizabeth A; Wilson, Robert S; Weuve, Jennifer; Barnes, Lisa L; Bianco, Antonio C; Evans, Denis A
2016-10-18
To examine if incident and preexisting diabetes mellitus (DM) were associated with cognitive decline among African Americans (AAs) and European Americans (EAs). Based on a prospective study of 7,740 older adults (mean age 72.3 years, 64% AA, 63% female), DM was ascertained by hypoglycemic medication use and Medicare claims during physician or hospital visits, and cognition by performance on a brief battery for executive functioning, episodic memory, and Mini-Mental State Examination (MMSE). Decline in composite and individual tests among those with incident DM, with preexisting DM, and without DM was studied using a linear mixed effects model with and without change point. At baseline, 737 (15%) AAs and 269 (10%) EAs had preexisting DM. Another 721 (17%) AAs and 289 (12%) EAs had incident DM in old age. Following incident DM, cognitive decline increased by 36% among AAs and by 40% among EAs compared to those without DM. No significant difference was observed between AAs and EAs (p = 0.64). However, cognitive decline increased by 17% among AAs with preexisting DM compared to those without DM, but no increased decline was observed among EAs with preexisting DM. In secondary analyses, faster decline in executive functioning and episodic memory was observed following incident DM. In old age, faster cognitive decline was present among AAs and EAs following incident DM, compared to cognitive decline prior to DM, and among those without DM. This underscores the need for stronger prevention and control of DM in old age. © 2016 American Academy of Neurology.
Tüzün, Nedim; Op de Beeck, Lin; Brans, Kristien I; Janssens, Lizanne; Stoks, Robby
2017-12-01
The rapidly increasing rate of urbanization has a major impact on the ecology and evolution of species. While increased temperatures are a key aspect of urbanization ("urban heat islands"), we have very limited knowledge whether this generates differentiation in thermal responses between rural and urban populations. In a common garden experiment, we compared the thermal performance curves (TPCs) for growth rate and mortality in larvae of the damselfly Coenagrion puella from three urban and three rural populations. TPCs for growth rate shifted vertically, consistent with the faster-slower theoretical model whereby the cold-adapted rural larvae grew faster than the warm-adapted urban larvae across temperatures. In line with costs of rapid growth, rural larvae showed lower survival than urban larvae across temperatures. The relatively lower temperatures hence expected shorter growing seasons in rural populations compared to the populations in the urban heat islands likely impose stronger time constraints to reach a certain developmental stage before winter, thereby selecting for faster growth rates. In addition, higher predation rates at higher temperature may have contributed to the growth rate differences between urban and rural ponds. A faster-slower differentiation in TPCs may be a widespread pattern along the urbanization gradient. The observed microgeographic differentiation in TPCs supports the view that urbanization may drive life-history evolution. Moreover, because of the urban heat island effect, urban environments have the potential to aid in developing predictions on the impact of climate change on rural populations.
Mechanical Determinants of Faster Change of Direction Speed Performance in Male Athletes.
DosʼSantos, Thomas; Thomas, Christopher; Jones, Paul A; Comfort, Paul
2017-03-01
Dos'Santos, T, Thomas, C, Jones, PA, and Comfort, P. Mechanical determinants of faster change of direction speed performance in male athletes. J Strength Cond Res 31(3): 696-705, 2017-Mechanical variables during change of directions, for example, braking and propulsive forces, impulses, and ground contact times (GCT) have been identified as determinants of faster change of direction speed (CODS) performance. The purpose of this study was to investigate the mechanical determinants of 180° CODS performance with mechanical characteristic comparisons between faster and slower performers; while exploring the role of the penultimate foot contact (PEN) during the change of direction. Forty multidirectional male athletes performed 6 modified 505 (mod505) trials (3 left and right), and ground reaction forces were collected across the PEN and final foot contact (FINAL) during the change of direction. Pearson's correlation coefficients and coefficients of determination were used to explore the relationship between mechanical variables and mod505 completion time. Independent T-tests and Cohen's d effect sizes (ES) were conducted between faster (n = 10) and slower (n = 10) mod505 performers to explore differences in mechanical variables. Faster CODS performance was associated (p ≤ 0.05) with shorter GCTs (r = 0.701-0.757), greater horizontal propulsive forces (HPF) (r = -0.572 to -0.611), greater horizontal braking forces (HBF) in the PEN (r = -0.337), lower HBF ratios (r = -0.429), and lower FINAL vertical impact forces (VIF) (r = 0.449-0.559). Faster athletes demonstrated significantly (p ≤ 0.05, ES = 1.08-2.54) shorter FINAL GCTs, produced lower VIF, lower HBF ratios, and greater HPF in comparison to slower athletes. These findings suggest that different mechanical properties are required to produce faster CODS performance, with differences in mechanical properties observed between fast and slower performers. Furthermore, applying a greater proportion of braking force during the PEN relative to the FINAL may be advantageous for turning performance.
Fully Convolutional Networks for Ground Classification from LIDAR Point Clouds
NASA Astrophysics Data System (ADS)
Rizaldy, A.; Persello, C.; Gevaert, C. M.; Oude Elberink, S. J.
2018-05-01
Deep Learning has been massively used for image classification in recent years. The use of deep learning for ground classification from LIDAR point clouds has also been recently studied. However, point clouds need to be converted into an image in order to use Convolutional Neural Networks (CNNs). In state-of-the-art techniques, this conversion is slow because each point is converted into a separate image. This approach leads to highly redundant computation during conversion and classification. The goal of this study is to design a more efficient data conversion and ground classification. This goal is achieved by first converting the whole point cloud into a single image. The classification is then performed by a Fully Convolutional Network (FCN), a modified version of CNN designed for pixel-wise image classification. The proposed method is significantly faster than state-of-the-art techniques. On the ISPRS Filter Test dataset, it is 78 times faster for conversion and 16 times faster for classification. Our experimental analysis on the same dataset shows that the proposed method results in 5.22 % of total error, 4.10 % of type I error, and 15.07 % of type II error. Compared to the previous CNN-based technique and LAStools software, the proposed method reduces the total error and type I error (while type II error is slightly higher). The method was also tested on a very high point density LIDAR point clouds resulting in 4.02 % of total error, 2.15 % of type I error and 6.14 % of type II error.
Induction of labor in women with a history of fast labor.
Kenny, Tiffany H; Fenton, Bradford W; Melrose, Erica L; McCarroll, Michele L; von Gruenigen, Vivian E
2016-01-01
History of fast labor is currently subjectively defined and inductions for non-medical indications are becoming restricted. We hypothesized that women induced for a history of fast labor do not have faster previous labors and do not deliver more quickly. A retrospective case-control cohort design studied multiparas undergoing elective induction at one high risk center. Outcomes of dyads electively induced for a history of previous fast labor indication (PFast) were compared to controls with a psychosocial indication. A total of 612 elective inductions with 1074 previous deliveries were evaluated: 81 (13%) PFast and 531 (87%) control. PFast had faster previous labors (median 5.5 h, IQR: 4.5-6) versus. control (10 h, IQR: 9-10.5; p < 0.001). Subsequent delivery time from start to expulsion was shorter for PFast (median 7 h, IQR: 5-9, p < 0.001) than controls with and without a previous labor <5.5 h (8.6 h, IQR: 6-14 and 9.5 h, IQR: 7-15, respectively). PFast were less likely to have a serious maternal complication. Neonatal complications were similar. Patients induced for a history of fast labor do have faster previous labors, suggesting a significant history of fast labor can be defined as <5.5 h. These women deliver more quickly and with lower morbidity than controls when subsequently induced, therefore the benefit may warrant the risk for a select number of women with a history of a prior labor length <5.5 h.
Yoga practice is associated with superior motor imagery performance.
Hartnoll, Susannah H; Punt, T David
2017-11-01
Yoga is an activity that aims to integrate physical, mental and spiritual elements and is an increasingly popular approach to enhancing physical fitness. The integration of imagery within yoga practice is considered an important component and may be critical in contributing to the benefits of yoga that have been reported. In this study, we tested whether individuals who practice yoga demonstrate superior performance on an objective measure of implicit motor imagery. Thirty-six participants (18 yoga, 18 non-yoga) matched for age, sex and handedness, undertook the hand laterality recognition task; an objective measure of implicit motor imagery performance. Accuracy and response times were gathered and analysed to determine any group differences as well as any differences relating to the typical hallmarks of imagery (i.e. dominance and awkwardness effects) on the task. Response Times (RTs) in the yoga group were significantly faster than controls (p < 0.05) and there was also a trend towards greater accuracy for the Yoga group (p = 0.073). Dominance effects (faster responses to images corresponding with the dominant limb) and Awkwardness effects (faster responses to images corresponding with natural compared with awkward postures) were evident across groups, supporting the participants' use of motor imagery in undertaking the task. Additionally, a Group × Awkwardness interaction (p < 0.05) revealed that the enhanced imagery performance for the yoga group was most pronounced for awkward postures. This is the first study to show that yoga practice is associated with superior motor imagery performance; an association that may be important in explaining the established rehabilitative value of yoga for chronic pain.
Yoga practice is associated with superior motor imagery performance.
Hartnoll, Susannah H; Punt, T David
2017-08-02
Yoga is an activity that aims to integrate physical, mental and spiritual elements and is an increasingly popular approach to enhancing physical fitness. The integration of imagery within yoga practice is considered an important component and may be critical in contributing to the benefits of yoga that have been reported. In this study, we tested whether individuals who practice yoga demonstrate superior performance on an objective measure of implicit motor imagery. Thirty-six participants (18 yoga, 18 nonyoga) matched for age, sex and handedness, undertook the hand laterality recognition task; an objective measure of implicit motor imagery performance. Accuracy and response times were gathered and analysed to determine any group differences as well as any differences relating to the typical hallmarks of imagery (i.e. dominance and awkwardness effects) on the task. Response Times (RTs) in the yoga group were significantly faster than controls (p < 0.05) and there was also a trend towards greater accuracy for the Yoga group (p = 0.073). Dominance effects (faster responses to images corresponding with the dominant limb) and Awkwardness effects (faster responses to images corresponding with natural compared with awkward postures) were evident across groups, supporting the participants' use of motor imagery in undertaking the task. Additionally, a Group × Awkwardness interaction (p < 0.05) revealed that the enhanced imagery performance for the yoga group was most pronounced for awkward postures. This is the first study to show that yoga practice is associated with superior motor imagery performance; an association that may be important in explaining the established rehabilitative value of yoga for chronic pain.
Self-Esteem and Mastery Trajectories in High School by Social Class and Gender
Falci, Christina D.
2011-01-01
Using longitudinal data from 769 white adolescents in the Midwest, this research applies a social structure and personality perspective to examine variation in self-esteem and mastery trajectories by gender and SES across the high school years. Analyses reveal that high SES adolescents experience significantly steeper gains in self-esteem and mastery compared to low SES adolescents, resulting in the reversal of SES differences in self-esteem and the emergence of significant SES differences in mastery. Pre-existing gender differences in self-esteem narrow between the 9th and 12th grade because self-esteem increases at a faster rate among girls than boys during high school. These SES and gender differences in self-concept growth are explained by changes in parent-adolescent relationship quality and stress exposure. Specifically, boys and adolescents with lower SES backgrounds experienced steeper declines in parent-adolescent relationship quality and steeper gains in chronic work strain compared to girls and low SES adolescents, respectively. PMID:21423844
A Comparative Study of Alternative Controls and Displays for by the Severely Physically Handicapped
NASA Technical Reports Server (NTRS)
Williams, D.; Simpson, C.; Barker, M.
1984-01-01
A modification of a row/column scanning system was investigated in order to increase the speed and accuracy with which communication aids can be accessed with one or two switches. A selection algorithm was developed and programmed in BASIC to automatically select individuals with the characteristic difficulty in controlling time dependent control and display systems. Four systems were compared: (1) row/column directed scan (2 switches); (2) row/column auto scan (1 switch); (3) row auto scan (1 switch); and (4) column auto scan (1 switch). For this sample population, there were no significant differences among systems for scan time to select the correct target. The row/column auto scan system resulted in significantly more errors than any of the other three systems. Thus, the most widely prescribed system for severely physically disabled individuals turns out for this group to have a higher error rate and no faster communication rate than three other systems that have been considered inappropriate for this group.
Evaluation of wound healing activity of ferulic acid in diabetic rats.
Ghaisas, Mahesh M; Kshirsagar, Shashank B; Sahane, Rajkumari S
2014-10-01
In diabetic patients, there is impairment in angiogenesis, neovascularisation and failure in matrix metalloproteineases (MMPs), keratinocyte and fibroblast functions, which affects wound healing mechanism. Hence, diabetic patients are more prone to infections and ulcers, which finally result in gangrene. Ferulic acid (FA) is a natural antioxidant found in fruits and vegetables, such as tomatoes, rice bran and sweet corn. In this study, wound healing activity of FA was evaluated in streptozotocin-induced diabetic rats using excision wound model. FA-treated wounds were found to epithelise faster as compared with diabetic wound control group. The hydroxyproline and hexosamine content increased significantly when compared with diabetic wound control. FA effectively inhibited the lipid peroxidation and elevated the catalase, superoxide dismutase, glutathione and nitric oxide levels along with the increase in the serum zinc and copper levels probably aiding the wound healing process. Hence, the results indicate that FA significantly promotes wound healing in diabetic rats. © 2012 The Authors. International Wound Journal © 2012 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
A significant upward shift in plant species optimum elevation during the 20th century.
Lenoir, J; Gégout, J C; Marquet, P A; de Ruffray, P; Brisse, H
2008-06-27
Spatial fingerprints of climate change on biotic communities are usually associated with changes in the distribution of species at their latitudinal or altitudinal extremes. By comparing the altitudinal distribution of 171 forest plant species between 1905 and 1985 and 1986 and 2005 along the entire elevation range (0 to 2600 meters above sea level) in west Europe, we show that climate warming has resulted in a significant upward shift in species optimum elevation averaging 29 meters per decade. The shift is larger for species restricted to mountain habitats and for grassy species, which are characterized by faster population turnover. Our study shows that climate change affects the spatial core of the distributional range of plant species, in addition to their distributional margins, as previously reported.
Carter, Richard T.
2017-01-01
Understandably, most locomotor analyses of bats have focused on flight mechanics and behaviors. However, we investigated nonflight locomotion in an effort to glean deeper insights into the evolutionary history of bats. We used high-speed video (300 Hz) to film and compare walking and climbing mechanics and kinematics between several species of the suborders Megachiroptera (Pteropodidae) versus Microchiroptera (Vespertilionidae and Phyllostomatidae). We found fundamentally distinctive behaviors, functional abilities, and performance outcomes between groups, but nearly homogeneous outcomes within groups. Megachiropterans exhibited climbing techniques and skills not found in microchiropterans and which aligned with other fully arboreal mammals. Megachiropterans climbed readily when placed in a head-up posture on a vertical surface, showed significantly greater ability than microchiropterans to abduct and extend the reach of their limbs, and climbed at a greater pace by using a more aggressive ipsilateral gait, at times being supported by only a single contact point. In addition, megachiropterans showed little ability to employ basic walking mechanics when placed on the ground, also a pattern observed in some highly adapted arboreal mammals. Conversely, microchiropterans resisted climbing vertical surfaces in a head-up posture, showed significantly less extension of their limbs, and employed a less-aggressive, slower contralateral gait with three points of contact. When walking, microchiropterans used the same gait they did when climbing which is representative of basic tetrapod terrestrial mechanics. Curiously, megachiropterans cycled their limbs significantly faster when climbing than when attempting to walk, whereas microchiropterans cycled their limbs at significantly faster rates when walking than when climbing. We contend that nonflight locomotion mechanics give a deep evolutionary view into the ancestral es locomotor platform on which flight was built in each of these groups. PMID:28957404
Alpha Lipoic Acid (ALA) effects on subchorionic hematoma: preliminary clinical results.
Porcaro, G; Brillo, E; Giardina, I; Di Iorio, R
2015-09-01
The clinic use of alpha Lipoic Acid (ALA) is linked to its capability to exert antioxidant effects and, more interestingly, to counteract the pathologic changes of complex networks of cytokines, chemokines and growth factors, restoring their physiological state. The aim of this randomized controlled clinical trial was to test the contribution of oral supplementation of ALA to the standard treatment with Progesterone vaginal suppositories, in healing subchorionic hematomas in patients with threatened miscarriage. Controls were administered only Progesterone suppositories. Nineteen pregnant women in the first trimester of gestation, with threatened miscarriage and ultrasound evidence of subchorionic hematoma, were included in the trial and randomly divided in two groups: controls, treated with 400 mg Progesterone (200 mg 2 times per day), given by vaginal suppositories, and case study treated with the same Progesterone dosage, plus ALA, given orally at the dose of 600 mg (300 mg 2 times per day, DAV®, Lo.Li. Pharma srl, Italy). Sixteen patients completed the trial. Treatment was performed until complete resolution of the clinical picture. In both groups, the subjects improved significantly but, in general, a better and faster evolution in the major signs of threatened miscarriage was observed in the subjects treated with ALA and Progesterone. In these patients, the speed of resorption of subchorionic hematoma was significantly (p ≤ 0.05) superior compared to controls. The ALA and Progesterone group showed a faster decrease or disappearance of all symptoms than that observed in the control group, however the difference was not significant. These preliminary results suggest that ALA supplementation significantly contributes to speed up the process of restoration of physiological conditions in threatened miscarriage and ameliorates the medical conditions of both the mothers and the foetus, probably modulating the networks of cytokines, growth factors and other molecules.
Cognitive function and advanced kidney disease: longitudinal trends and impact on decision-making.
Iyasere, Osasuyi; Okai, David; Brown, Edwina
2017-02-01
Background: Cognitive impairment commonly affects renal patients. But little is known about the influence of dialysis modality on cognitive trends or the influence of cognitive impairment on decision-making in renal patients. This study evaluated cognitive trends amongst chronic kidney disease (CKD), haemodialysis (HD) and peritoneal dialysis (PD) patients. The relationship between cognitive impairment and decision-making capacity (DMC) was also assessed. Methods: Patients were recruited from three outpatient clinics. Cognitive function was assessed 4-monthly for up to 2 years, using the Montreal Cognitive Assessment (MoCA) tool. Cognitive trends were assessed using mixed model analysis. DMC was assessed using the Macarthur Competency Assessment tool (MacCAT-T). MacCAT-T scores were compared between patients with cognitive impairment (MoCA <26) and those without. Results: In total, 102 (41 HD, 25 PD and 36 CKD) patients were recruited into the prospective study. After multivariate analysis, the total MoCA scores declined faster in dialysis compared with CKD patients [coefficient = -0.03, 95% confidence interval (95% CI) = -0.056 to - 0.004; P = 0.025]. The MoCA executive scores declined faster in the HD compared with PD patients (coefficient = -0.12, 95% CI = -0.233 to - 0.007; P = 0.037). DMC was assessed in 10 patients. Those with cognitive impairment had lower MacCAT-T compared with those without [median (interquartile range) 19 (17.9-19.6) versus 17.4 (16.3-18.4); P = 0.049]. Conclusions: Cognition declines faster in dialysis patients compared with CKD patients and in HD patients compared with PD patients. Cognitive impairment affects DMC in patients with advanced kidney disease.
The Simplest Chronoscope V: A Theory of Dual Primary and Secondary Reaction Time Systems.
Montare, Alberto
2016-12-01
Extending work by Montare, visual simple reaction time, choice reaction time, discriminative reaction time, and overall reaction time scores obtained from college students by the simplest chronoscope (a falling meterstick) method were significantly faster as well as significantly less variable than scores of the same individuals from electromechanical reaction timers (machine method). Results supported the existence of dual reaction time systems: an ancient primary reaction time system theoretically activating the V5 parietal area of the dorsal visual stream that evolved to process significantly faster sensory-motor reactions to sudden stimulations arising from environmental objects in motion, and a secondary reaction time system theoretically activating the V4 temporal area of the ventral visual stream that subsequently evolved to process significantly slower sensory-perceptual-motor reactions to sudden stimulations arising from motionless colored objects. © The Author(s) 2016.
Taylor Series Trajectory Calculations Including Oblateness Effects and Variable Atmospheric Density
NASA Technical Reports Server (NTRS)
Scott, James R.
2011-01-01
Taylor series integration is implemented in NASA Glenn's Spacecraft N-body Analysis Program, and compared head-to-head with the code's existing 8th- order Runge-Kutta Fehlberg time integration scheme. This paper focuses on trajectory problems that include oblateness and/or variable atmospheric density. Taylor series is shown to be significantly faster and more accurate for oblateness problems up through a 4x4 field, with speedups ranging from a factor of 2 to 13. For problems with variable atmospheric density, speedups average 24 for atmospheric density alone, and average 1.6 to 8.2 when density and oblateness are combined.
Region Based CNN for Foreign Object Debris Detection on Airfield Pavement
Cao, Xiaoguang; Wang, Peng; Meng, Cai; Gong, Guoping; Liu, Miaoming; Qi, Jun
2018-01-01
In this paper, a novel algorithm based on convolutional neural network (CNN) is proposed to detect foreign object debris (FOD) based on optical imaging sensors. It contains two modules, the improved region proposal network (RPN) and spatial transformer network (STN) based CNN classifier. In the improved RPN, some extra select rules are designed and deployed to generate high quality candidates with fewer numbers. Moreover, the efficiency of CNN detector is significantly improved by introducing STN layer. Compared to faster R-CNN and single shot multiBox detector (SSD), the proposed algorithm achieves better result for FOD detection on airfield pavement in the experiment. PMID:29494524
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Xiaobiao; Safranek, James
2014-09-01
Nonlinear dynamics optimization is carried out for a low emittance upgrade lattice of SPEAR3 in order to improve its dynamic aperture and Touschek lifetime. Two multi-objective optimization algorithms, a genetic algorithm and a particle swarm algorithm, are used for this study. The performance of the two algorithms are compared. The result shows that the particle swarm algorithm converges significantly faster to similar or better solutions than the genetic algorithm and it does not require seeding of good solutions in the initial population. These advantages of the particle swarm algorithm may make it more suitable for many accelerator optimization applications.
Region Based CNN for Foreign Object Debris Detection on Airfield Pavement.
Cao, Xiaoguang; Wang, Peng; Meng, Cai; Bai, Xiangzhi; Gong, Guoping; Liu, Miaoming; Qi, Jun
2018-03-01
In this paper, a novel algorithm based on convolutional neural network (CNN) is proposed to detect foreign object debris (FOD) based on optical imaging sensors. It contains two modules, the improved region proposal network (RPN) and spatial transformer network (STN) based CNN classifier. In the improved RPN, some extra select rules are designed and deployed to generate high quality candidates with fewer numbers. Moreover, the efficiency of CNN detector is significantly improved by introducing STN layer. Compared to faster R-CNN and single shot multiBox detector (SSD), the proposed algorithm achieves better result for FOD detection on airfield pavement in the experiment.
Ho, Derek; Drake, Tyler K.; Bentley, Rex C.; Valea, Fidel A.; Wax, Adam
2015-01-01
We evaluate a new hybrid algorithm for determining nuclear morphology using angle-resolved low coherence interferometry (a/LCI) measurements in ex vivo cervical tissue. The algorithm combines Mie theory based and continuous wavelet transform inverse light scattering analysis. The hybrid algorithm was validated and compared to traditional Mie theory based analysis using an ex vivo tissue data set. The hybrid algorithm achieved 100% agreement with pathology in distinguishing dysplastic and non-dysplastic biopsy sites in the pilot study. Significantly, the new algorithm performed over four times faster than traditional Mie theory based analysis. PMID:26309741
Effect of food service form on eating rate: meal served in a separated form might lower eating rate.
Suh, Hyung Joo; Jung, Eun Young
2016-01-01
In this study, we investigated the association between food form (mixed vs separated) and eating rate. The experiment used a within-subjects design (n=29, young healthy women with normal weight). Test meals (white rice and side dishes) with the same content and volume were served at lunch in a mixed or separated form. The form in which the food was served had significant effects on consumption volume and eating rate; subjects ate significantly more (p<0.05) when a test meal was served as a mixed form (285 g, 575 kcal) compared to a separated form (244 g, 492 kcal). Moreover, subjects also ate significantly faster (p<0.05) when the test meal was served as a mixed form (22.4 g/min) as compared to a separated form (16.2 g/min). Despite consuming more when the test meal was served as a mixed form than when served as a separated form, the subjects did not feel significantly fuller. In conclusion, we confirmed that meals served in a separated form might lower the eating rate and, moreover, slower eating might be associated with less energy intake, without compromising satiety.
Park, Jin Ha; Lee, Jong Seok; Nam, Sang Beom; Ju, Jin Wu
2016-01-01
Purpose Supraglottic airway devices have been widely utilized as an alternative to tracheal intubation in various clinical situations. The rotation technique has been proposed to improve the insertion success rate of supraglottic airways. However, the clinical efficacy of this technique remains uncertain as previous results have been inconsistent, depending on the variable evaluated. Materials and Methods We systematically searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials in April 2015 for randomized controlled trials that compared the rotation and standard techniques for inserting supraglottic airways. Results Thirteen randomized controlled trials (1505 patients, 753 with the rotation technique) were included. The success rate at the first attempt was significantly higher with the rotation technique than with the standard technique [relative risk (RR): 1.13; 95% confidence interval (CI): 1.05 to 1.23; p=0.002]. The rotation technique provided significantly higher overall success rates (RR: 1.06; 95% CI: 1.04 to 1.09; p<0.001). Device insertion was completed faster with the rotation technique (mean difference: -4.6 seconds; 95% CI: -7.37 to -1.74; p=0.002). The incidence of blood staining on the removed device (RR: 0.36; 95% CI: 0.27 to 0.47; p<0.001) was significantly lower with the rotation technique. Conclusion The rotation technique provided higher first-attempt and overall success rates, faster insertion, and a lower incidence of blood on the removed device, reflecting less mucosal trauma. Thus, it may be considered as an alternative to the standard technique when predicting or encountering difficulty in inserting supraglottic airways. PMID:27189296
Effects of youth football on selected clinical measures of neurologic function: a pilot study.
Munce, Thayne A; Dorman, Jason C; Odney, Tryg O; Thompson, Paul A; Valentine, Verle D; Bergeron, Michael F
2014-12-01
We assessed 10 youth football players (13.4 ± 0.7 y) immediately before and after their season to explore the effects of football participation on selected clinical measures of neurologic function. Postseason postural stability in a closed-eye condition was improved compared to preseason (P = .017). Neurocognitive testing with the Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) battery revealed that reaction time was significantly faster at postseason (P = .015). There were no significant preseason versus postseason differences in verbal memory (P = .507), visual memory (P = .750), or visual motor speed (P = .087). Oculomotor performance assessed by the King-Devick test was moderately to significantly improved (P = .047-.115). A 12-week season of youth football did not impair the postural stability, neurocognitive function, or oculomotor performance measures of the players evaluated. Though encouraging, continued and more comprehensive investigations of this at-risk population are warranted. © The Author(s) 2013.
Statistical Modeling of Zr/Hf Extraction using TBP-D2EHPA Mixtures
NASA Astrophysics Data System (ADS)
Rezaeinejhad Jirandehi, Vahid; Haghshenas Fatmehsari, Davoud; Firoozi, Sadegh; Taghizadeh, Mohammad; Keshavarz Alamdari, Eskandar
2012-12-01
In the present work, response surface methodology was employed for the study and prediction of Zr/Hf extraction curves in a solvent extraction system using D2EHPA-TBP mixtures. The effect of change in the levels of temperature, nitric acid concentration, and TBP/D2EHPA ratio (T/D) on the Zr/Hf extraction/separation was studied by the use of central composite design. The results showed a statistically significant effect of T/D, nitric acid concentration, and temperature on the extraction percentage of Zr and Hf. In the case of Zr, a statistically significant interaction was found between T/D and nitric acid, whereas for Hf, both interactive terms between temperature and T/D and nitric acid were significant. Additionally, the extraction curves were profitably predicted applying the developed statistical regression equations; this approach is faster and more economical compared with experimentally obtained curves.
Hodd, Jack A R; Doyle, D John; Gupta, Shipra; Dalton, Jarrod E; Cata, Juan P; Brewer, Edward J; James, Monyulona; Sessler, Daniel I
2011-10-01
The AP Advance (APA) is a videolaryngoscope with interchangeable blades: intubators can choose standard Macintosh blades or a difficult-airway blade with increased curvature and a channel to guide the tube to the larynx. The APA may therefore be comparably effective in both normal and difficult airways. We tested the hypotheses that intubation with the APA is no slower than Macintosh laryngoscopy for normal mannequin airways, and that it is no slower than videolaryngoscopy using a GlideScope Ranger in difficult mannequin airways. Medical professionals whose roles potentially include tracheal intubation were trained with each device. Participants intubated simulated (Laerdal SimMan) normal and difficult airways with the APA, GlideScope, and a conventional Macintosh blade. Speed of intubation was compared using Cox proportional hazards regression, with a hazard ratio >0.8 considered noninferior. We also compared laryngeal visualization, failures, and participant preferences. Unadjusted intubation times in the normal airway with the APA and Macintosh were virtually identical (median, 22 vs 23 seconds); after adjustment for effects of experience, order, and period, the hazard ratio (95% confidence interval) comparing APA with Macintosh laryngoscopy was 0.87 (0.65, 1.17), which was not significantly more than our predefined noninferiority boundary of 0.8 (P = 0.26). Intubation with the APA was faster than with the GlideScope in difficult airways (hazard ratio = 7.6 [5.0, 11.3], P < 0.001; median, 20 vs 59 seconds). All participants intubated the difficult airway mannequin with the APA, whereas 33% and 37% failed with the GlideScope and Macintosh, respectively. In the difficult airway, 99% of participants achieved a Cormack and Lehane grade I to II view with the APA, versus 85% and 33% with the GlideScope and Macintosh, respectively. When asked to choose 1 device overall, 82% chose the APA. Intubation times were similar with the APA and Macintosh laryngoscopes in mannequins with normal airways. However, intubation with the APA was significantly faster than with the GlideScope in the difficult mannequin simulation.
Noah, Benjamin; Li, Jingwen; Rothrock, Ling
2017-10-01
The objectives of this study were to test the effect of interaction device on performance in a process control task (managing a tank farm). The study compared the following two conditions: a) 4K-resolution 55" screen with a 21" touchscreen versus b) 4K-resolution 55″ screen with keyboard/mouse. The touchscreen acted both as an interaction device for data entry and navigation and as an additional source of information. A within-subject experiment was conducted among 20 college engineering students. A primary task of preventing tanks from overfilling as well as a secondary task of manual logging with situation awareness questions were designed for the study. Primary Task performance (including tank level at discharge, number of tank discharged and performance score), Secondary Task Performance (including Tank log count, performance score), system interaction times, subjective workload, situation awareness questionnaire, user experience survey regarding usability and condition comparison were used as the measures. Parametric data resulted in two metrics statistically different means between the two conditions: The 4K-keyboard condition resulted in faster Detection + Navigation time compared to the 4K-touchscreen condition, by about 2 s, while participants within the 4K-touchscreen condition were about 2 s faster in data entry than in the 4K-keyboard condition. No significant results were found for: performance on the secondary task, situation awareness, and workload. Additionally, no clear significant differences were found in the non-parametric data analysis. However, participants showed a slight preference for the 4K-touchscreen condition compared to the 4K-keyboard condition in subjective responses in comparing the conditions. Introducing the touchscreen as an additional/alternative input device showed to have an effect in interaction times, which suggests that proper design considerations need to be made. While having values shown on the interaction device provides value, a potential issue of visual distraction exists when having an additional visual display. The allocation of visual attention between primary displays and the touchscreen should be further investigated. Copyright © 2017 Elsevier Ltd. All rights reserved.
Huang, Peng; Sengupta, Dilip K
2014-04-15
A single-center retrospective study. To compare the speed of recovery of different sensory symptoms, pain, numbness, and paresthesia, after lumbar nerve root decompression. Lumbar radiculopathy is characterized by different sensory symptoms like pain, numbness, and paresthesia, which may resolve at different rates after surgical decompression. Eighty-five cases with predominant lumbar radiculopathy treated surgically were reviewed. Oswestry Disability Index score, 36-Item Short Form Health Survey scores (Physical Component Summary and Mental Component Summary), and pain drawing at preoperative and at 6 weeks, 3 months, 6 months, and 1-year follow-up were reviewed. Recovery rate between different sensory symptoms were compared in all patients, and between the short-term compression (<6 mo) and long-term compression groups. At baseline, 73 (85.8%) patients had pain, 63 (74.1%) had numbness, and 38 (44.7%) had paresthesia; 28 (32.9%) had all these 3 component of sensory symptoms. Mean pain score improved fastest (55.3% at 6 wk); further resolution until 1 year was slow and not significant compared with each previous visit. Both numbness and paresthesia scores showed a trend of faster recovery during the initial 6-week period (20.5% and 24%, respectively); paresthesia recovery reached a plateau at 3 months postoperatively, but numbness continued a slow recovery until 1-year follow-up. Both Oswestry Disability Index score and Physical Component Summary scores (54.02 ± 1.87 and 26.29 ± 0.93, respectively, at baseline) improved significantly compared with each previous visits at 6 weeks and 3 months postoperatively, but further improvement was insignificant. Mental Component Summary showed a similar trend but smaller improvement. The short-term compression group had faster recovery of pain than the long-term compression group. In lumbar radiculopathy patients after surgical decompression, pain recovers fastest, in the first 6 weeks postoperatively, followed by paresthesia recovery that plateaus at 3 months postoperatively. Numbness recovers at a slower pace but continues until 1 year. 4.
NASA Technical Reports Server (NTRS)
1994-01-01
A NASA contract led to the development of faster and more energy efficient semiconductor materials for digital integrated circuits. Gallium arsenide (GaAs) conducts electrons 4-6 times faster than silicon and uses less power at frequencies above 100-150 megahertz. However, the material is expensive, brittle, fragile and has lacked computer automated engineering tools to solve this problem. Systems & Processes Engineering Corporation (SPEC) developed a series of GaAs cell libraries for cell layout, design rule checking, logic synthesis, placement and routing, simulation and chip assembly. The system is marketed by Compare Design Automation.
Intervertebral disc detection in X-ray images using faster R-CNN.
Ruhan Sa; Owens, William; Wiegand, Raymond; Studin, Mark; Capoferri, Donald; Barooha, Kenneth; Greaux, Alexander; Rattray, Robert; Hutton, Adam; Cintineo, John; Chaudhary, Vipin
2017-07-01
Automatic identification of specific osseous landmarks on the spinal radiograph can be used to automate calculations for correcting ligament instability and injury, which affect 75% of patients injured in motor vehicle accidents. In this work, we propose to use deep learning based object detection method as the first step towards identifying landmark points in lateral lumbar X-ray images. The significant breakthrough of deep learning technology has made it a prevailing choice for perception based applications, however, the lack of large annotated training dataset has brought challenges to utilizing the technology in medical image processing field. In this work, we propose to fine tune a deep network, Faster-RCNN, a state-of-the-art deep detection network in natural image domain, using small annotated clinical datasets. In the experiment we show that, by using only 81 lateral lumbar X-Ray training images, one can achieve much better performance compared to traditional sliding window detection method on hand crafted features. Furthermore, we fine-tuned the network using 974 training images and tested on 108 images, which achieved average precision of 0.905 with average computation time of 3 second per image, which greatly outperformed traditional methods in terms of accuracy and efficiency.
Do we really need sugammadex as an antagonist of muscle relaxants in anesthesia?
Meistelman, Claude; Donati, François
2016-08-01
Sugammadex is a selective relaxant-binding agent that is designed to encapsulate rocuronium and chemically similar steroidal muscle relaxants such as vecuronium. This review summarizes recent information on the use of sugammadex in clinical practice. The main advantages of sugammadex when compared with conventional anticholinesterase agents are a much faster recovery time and its unique ability to reverse rapidly and efficiently, for the first time, deep levels of neuromuscular blockade. However, there is paucity of evidence-based studies on the benefit of deep neuromuscular block, and then routine administration of sugammadex to reverse any level of block, for example, during laparoscopic surgery. It appears that reduction of costs depends mainly on organizational factors. Finally it must be remembered that sugammadex only works with steroidal nondepolarizing muscle relaxants; therefore neostigmine should not be withdrawn because it is the only reversal agent effective against atracurium or cisatracurium. Sugammadex offers a significantly faster and more predictable recovery profile than neostigmine. It is now possible to reverse rapidly and efficiently any level of neuromuscular blockade and to avoid the risk of adverse events because of residual paralysis such as critical respiratory events during recovery from anesthesia.
NASA Astrophysics Data System (ADS)
Budhijanto, Wiratni; Darlianto, Deen; Pradana, Yano Surya; Hartono, Muhamad
2017-05-01
This study aimed to apply a novel type of aerator called Micro Bubble Generator (MBG) for fresh water fish farming. The MBG was run based on the principle of venturi tube in which water was circulated through a narrowed channel so that air was sucked into the device and pushed by the flowing water to create micro-sized bubble. The MBG aerator was tested on the aquaculture of tilapia fish to be compared to conventional aerator (the bubbler currently used in aquaculture experiments) and control (container with no aeration). The population of 150 tilapia fish of the average initial length of 6.44 cm was tested in each container. The water quality parameters (COD, pH, and TAN) and fish growth parameters (length and weight) were observed for 68 days. The results highlighted the promising potential of MBG as affordable aerator to be applied in intensive aquaculture. Although the dissolved oxygen level did not differ significantly with the conventional aerator, MBG aerator indicated faster degradation of organic content in the water and induced faster growth of the fish as measured by their length and weight.
Processing language in face-to-face conversation: Questions with gestures get faster responses.
Holler, Judith; Kendrick, Kobin H; Levinson, Stephen C
2017-09-08
The home of human language use is face-to-face interaction, a context in which communicative exchanges are characterised not only by bodily signals accompanying what is being said but also by a pattern of alternating turns at talk. This transition between turns is astonishingly fast-typically a mere 200-ms elapse between a current and a next speaker's contribution-meaning that comprehending, producing, and coordinating conversational contributions in time is a significant challenge. This begs the question of whether the additional information carried by bodily signals facilitates or hinders language processing in this time-pressured environment. We present analyses of multimodal conversations revealing that bodily signals appear to profoundly influence language processing in interaction: Questions accompanied by gestures lead to shorter turn transition times-that is, to faster responses-than questions without gestures, and responses come earlier when gestures end before compared to after the question turn has ended. These findings hold even after taking into account prosodic patterns and other visual signals, such as gaze. The empirical findings presented here provide a first glimpse of the role of the body in the psycholinguistic processes underpinning human communication.
SEXUAL SPECIES ARE SEPARATED BY LARGER GENETIC GAPS THAN ASEXUAL SPECIES IN ROTIFERS
Tang, Cuong Q; Obertegger, Ulrike; Fontaneto, Diego; Barraclough, Timothy G
2014-01-01
Why organisms diversify into discrete species instead of showing a continuum of genotypic and phenotypic forms is an important yet rarely studied question in speciation biology. Does species discreteness come from adaptation to fill discrete niches or from interspecific gaps generated by reproductive isolation? We investigate the importance of reproductive isolation by comparing genetic discreteness, in terms of intra- and interspecific variation, between facultatively sexual monogonont rotifers and obligately asexual bdelloid rotifers. We calculated the age (phylogenetic distance) and average pairwise genetic distance (raw distance) within and among evolutionarily significant units of diversity in six bdelloid clades and seven monogonont clades sampled for 4211 individuals in total. We find that monogonont species are more discrete than bdelloid species with respect to divergence between species but exhibit similar levels of intraspecific variation (species cohesiveness). This pattern arises because bdelloids have diversified into discrete genetic clusters at a faster net rate than monogononts. Although sampling biases or differences in ecology that are independent of sexuality might also affect these patterns, the results are consistent with the hypothesis that bdelloids diversified at a faster rate into less discrete species because their diversification does not depend on the evolution of reproductive isolation. PMID:24975991
Longitudinal changes in speech recognition in older persons.
Dubno, Judy R; Lee, Fu-Shing; Matthews, Lois J; Ahlstrom, Jayne B; Horwitz, Amy R; Mills, John H
2008-01-01
Recognition of isolated monosyllabic words in quiet and recognition of key words in low- and high-context sentences in babble were measured in a large sample of older persons enrolled in a longitudinal study of age-related hearing loss. Repeated measures were obtained yearly or every 2 to 3 years. To control for concurrent changes in pure-tone thresholds and speech levels, speech-recognition scores were adjusted using an importance-weighted speech-audibility metric (AI). Linear-regression slope estimated the rate of change in adjusted speech-recognition scores. Recognition of words in quiet declined significantly faster with age than predicted by declines in speech audibility. As subjects aged, observed scores deviated increasingly from AI-predicted scores, but this effect did not accelerate with age. Rate of decline in word recognition was significantly faster for females than males and for females with high serum progesterone levels, whereas noise history had no effect. Rate of decline did not accelerate with age but increased with degree of hearing loss, suggesting that with more severe injury to the auditory system, impairments to auditory function other than reduced audibility resulted in faster declines in word recognition as subjects aged. Recognition of key words in low- and high-context sentences in babble did not decline significantly with age.
Donovan, Oliver O; Cheung, Jeanette; Catley, Maria; McGregor, Alison H; Strutton, Paul H
2006-01-01
The purpose of this study was to investigate trunk and knee strength in practitioners of hard-style martial arts. An additional objective was to examine reaction times in these participants by measuring simple reaction times (SRT), choice reaction times (CRT) and movement times (MT). Thirteen high-level martial artists and twelve sedentary participants were tested under isokinetic and isometric conditions on an isokinetic dynamometer. Response and movement times were also measured in response to simple and choice auditory cues. Results indicated that the martial arts group generated a greater body-weight adjusted peak torque with both legs at all speeds during isokinetic extension and flexion, and in isometric extension but not flexion. In isokinetic and isometric trunk flexion and extension, martial artists tended to have higher peak torques than controls, but they were not significantly different (p > 0.05). During the SRT and CRT tasks the martial artists were no quicker in lifting their hand off a button in response to the stimulus [reaction time (RT)] but were significantly faster in moving to press another button [movement time (MT)]. In conclusion, the results reveal that training in a martial art increases the strength of both the flexors and extensors of the leg. Furthermore, they have faster movement times to auditory stimuli. These results are consistent with the physical aspects of the martial arts. Key PointsMartial artists undertaking hard-style martial arts have greater strength in their knee flexor and extensor muscles as tested under isokinetic testing. Under isometric testing conditions they have stronger knee extensors only.The trunk musculature is generally higher under both conditions of testing in the martial artists, although not significantly.The total reaction times of the martial artists to an auditory stimulus were significantly faster than the control participants. When analysed further it was revealed that the decrease in reaction time was due to the movement time component of the total reaction time.The training involved for the practice of the hard-style martial arts increases the strength of muscles involved in kicking. This increased strength is not seen in the trunk muscles. Furthermore, martial artists have a faster response time; the cause of which appears to be only the faster movement time.
Donovan, Oliver O; Cheung, Jeanette; Catley, Maria; McGregor, Alison H.; Strutton, Paul H.
2006-01-01
The purpose of this study was to investigate trunk and knee strength in practitioners of hard-style martial arts. An additional objective was to examine reaction times in these participants by measuring simple reaction times (SRT), choice reaction times (CRT) and movement times (MT). Thirteen high-level martial artists and twelve sedentary participants were tested under isokinetic and isometric conditions on an isokinetic dynamometer. Response and movement times were also measured in response to simple and choice auditory cues. Results indicated that the martial arts group generated a greater body-weight adjusted peak torque with both legs at all speeds during isokinetic extension and flexion, and in isometric extension but not flexion. In isokinetic and isometric trunk flexion and extension, martial artists tended to have higher peak torques than controls, but they were not significantly different (p > 0.05). During the SRT and CRT tasks the martial artists were no quicker in lifting their hand off a button in response to the stimulus [reaction time (RT)] but were significantly faster in moving to press another button [movement time (MT)]. In conclusion, the results reveal that training in a martial art increases the strength of both the flexors and extensors of the leg. Furthermore, they have faster movement times to auditory stimuli. These results are consistent with the physical aspects of the martial arts. Key Points Martial artists undertaking hard-style martial arts have greater strength in their knee flexor and extensor muscles as tested under isokinetic testing. Under isometric testing conditions they have stronger knee extensors only. The trunk musculature is generally higher under both conditions of testing in the martial artists, although not significantly. The total reaction times of the martial artists to an auditory stimulus were significantly faster than the control participants. When analysed further it was revealed that the decrease in reaction time was due to the movement time component of the total reaction time. The training involved for the practice of the hard-style martial arts increases the strength of muscles involved in kicking. This increased strength is not seen in the trunk muscles. Furthermore, martial artists have a faster response time; the cause of which appears to be only the faster movement time. PMID:24376366
Tissue adhesives for closure of surgical incisions.
Coulthard, Paul; Esposito, Marco; Worthington, Helen V; van der Elst, Maarten; van Waes, Oscar J F; Darcey, James
2010-05-12
Sutures, staples and adhesive tapes are the traditional methods of wound closure, whilst tissue adhesives have entered clinical practice more recently. Closure of wounds with sutures enables meticulous closure, but they may show tissue reactivity and can require removal. Tissue adhesives offer the advantages of no risk of needlestick injury and no requirement to remove sutures later. Tissue adhesives have been used primarily in emergency rooms but this review looks at the use of tissue adhesives in the operating room where surgeons are increasingly using these for the closure of surgical skin incisions. To determine the relative effects of various tissue adhesives and conventional skin closure techniques on the healing of surgical wounds. For this update we searched the Cochrane Wounds Group Specialised Register (Searched 17/11/09); The Cochrane Central Register of Controlled Trials (CENTRAL) - The Cochrane Library Issue 4 2009; Ovid MEDLINE - 1950 to November Week 1 2009; Ovid EMBASE - 1980 to 2009 Week 46; EBSCO CINAHL - 1982 to 17 November 20098. No date or language restrictions were applied. Only randomised controlled clinical trials were eligible for inclusion. Screening of eligible studies and data extraction were conducted independently and in triplicate whilst assessment of the methodological quality of the trials was conducted independently and in duplicate. Results were expressed as random effects models using mean difference for continuous outcomes and relative risks with 95% confidence intervals for dichotomous outcomes. Heterogeneity was investigated including both clinical and methodological factors. This update identified an additional six trials resulting in a total of fourteen RCTs (1152 patients) which met the inclusion criteria. Sutures were significantly better than tissue adhesives for minimising dehiscence (10 trials). Sutures were also found to be significantly faster to use. For all other analyses of infection, patient and operator satisfaction and cost there was no significant difference between sutures and tissue adhesives. No differences were found between tissue adhesives and tapes (2 trials) for minimising dehiscence, infection, patients assessment of cosmetic appearance, patient satisfaction or surgeon satisfaction. However a statistically significant difference in favour of using tape was found for surgeons' assessment of cosmetic appearance (mean difference 13, 95% CI 5 to 21). Tapes were also demonstrated to be significantly faster to use than tissue adhesives as were staples (1 trial). No other outcome measures were analysed in this group. One trial compared tissue adhesives with a variety of methods of wound closure and found both patients and clinicians were significantly more satisfied with the alternative closure methods than the adhesives. In this same trial tissue adhesives were significantly less time consuming to use. For the remaining outcomes of dehiscence and infection no difference was observed between groups. This trial also compared high viscosity with low viscosity adhesives and found that high viscosity adhesives were less time consuming to use than low viscosity tissue adhesives. For all other outcomes of dehiscence, infection, patient satisfaction and operator satisfaction there was no statistically significant difference between high and low viscosity adhesives. Sutures were significantly better than tissue adhesives for minimising dehiscence and were found to be significantly faster to use. Although surgeons may consider the use of tissue adhesives as an alternative to other methods of surgical site closure in the operating theatre they must be aware that adhesives may take more time to apply and that if higher tension is needed upon an incision, sutures may minimise dehiscence. There is a need for more well designed randomised controlled trials comparing tissue adhesives and alternative methods of closure. These trials should include people whose health may interfere with wound healing and surgical sites of high tension.
Place and response learning in human virtual navigation: behavioral measures and gender differences.
Schmitzer-Torbert, Neil
2007-04-01
Two experiments examined the use of place and response strategies by humans navigating virtual multiple T mazes. In Experiment 1, probe trials revealed that participants commonly used place and response strategies, and place strategies were more frequent early in training, whereas response strategies were more frequent late in training. Compared with women, men learned the correct path through the maze more quickly and developed a more stable route through the maze. In Experiment 2, participants were trained to locate 2 targets. One target required participants to use either a place or response strategy, whereas the other target could be found using either strategy. Accuracy improved faster for place training compared with response training, and women outperformed men in both groups. Probe trials testing transfer of the imposed strategy to the other target found faster transfer for place training than for response training and that women demonstrated faster transfer than men. Accuracy on probe trials was correlated with poor route stability in the place-trained group and with good route stability in the response-trained group, indicating that navigation strategy use may be related to measures of improvement in performance on normal trials. (c) 2007 APA, all rights reserved
Dilday, Joshua; Sirkin, Maxwell R; Wertin, Thomas; Bradley, Frances; Hiles, Jason
The current forward surgical team (FST) operating table is heavy and burdensome and hinders essential movement flexibility. A novel attachable rail system, the Shrail, has been developed to overcome these obstacles. The Shrail turns a North Atlantic Treaty Organization litter into a functional operating table. A local FST compared the assembly of the FST operating table with assembling the Shrail. Device weight, storage space, and assembly space were directly measured and compared. The mean assembly time required for the Shrail was significantly less compared with the operating table (23.36 versus 151.6 seconds; p ≤ .01). The Shrail weighs less (6.80kg versus 73.03kg) and requires less storage space (0.019m3 versus 0.323m3) compared with the current FST operating table. The Shrail provides an FST with a faster, lighter surgical table assembly. For these reasons, it is better suited for the demands of an FST and the implementation of prolonged field care. 2018.
Melich, George; Hong, Young Ki; Kim, Jieun; Hur, Hyuk; Baik, Seung Hyuk; Kim, Nam Kyu; Sender Liberman, A; Min, Byung Soh
2015-03-01
Laparoscopy offers some evidence of benefit compared to open rectal surgery. Robotic rectal surgery is evolving into an accepted approach. The objective was to analyze and compare laparoscopic and robotic rectal surgery learning curves with respect to operative times and perioperative outcomes for a novice minimally invasive colorectal surgeon. One hundred and six laparoscopic and 92 robotic LAR rectal surgery cases were analyzed. All surgeries were performed by a surgeon who was primarily trained in open rectal surgery. Patient characteristics and perioperative outcomes were analyzed. Operative time and CUSUM plots were used for evaluating the learning curve for laparoscopic versus robotic LAR. Laparoscopic versus robotic LAR outcomes feature initial group operative times of 308 (291-325) min versus 397 (373-420) min and last group times of 220 (212-229) min versus 204 (196-211) min-reversed in favor of robotics; major complications of 4.7 versus 6.5 % (NS), resection margin involvement of 2.8 versus 4.4 % (NS), conversion rate of 3.8 versus 1.1 (NS), lymph node harvest of 16.3 versus 17.2 (NS), and estimated blood loss of 231 versus 201 cc (NS). Due to faster learning curves for extracorporeal phase and total mesorectal excision phase, the robotic surgery was observed to be faster than laparoscopic surgery after the initial 41 cases. CUSUM plots demonstrate acceptable perioperative surgical outcomes from the beginning of the study. Initial robotic operative times improved with practice rapidly and eventually became faster than those for laparoscopy. Developing both laparoscopic and robotic skills simultaneously can provide acceptable perioperative outcomes in rectal surgery. It might be suggested that in the current milieu of clashing interests between evolving technology and economic constrains, there might be advantages in embracing both approaches.
Substance P in Flush Tears and Schirmer Strips of Healthy Participants.
Markoulli, Maria; Gokhale, Moneisha; You, Jingjing
2017-04-01
To determine the repeatability of the flush tear collection technique and the Schirmer strip for Substance P tear analysis. The tears of 10 healthy non-contact-lens wearers were collected via Schirmer strip and microcapillary following instillation of either 20 μL (F-20) or 60 μL (F-60) of saline. Each technique was conducted on two occasions and in a randomized order. Total protein content (TPC) and Substance P concentrations were determined. The overall protein separation profile of each type of tears was examined using one-dimensional gel electrophoresis (1DGE). Collection rates were significantly faster for the F-60 compared to F-20 (17.3 ± 6.9 μL/min and 11.9 ± 5.3 μL/min, respectively, P < .001), with an average Schirmer strip length of 1.5 ± 2.1 mm/min. The coefficient of repeatability between days and eyes was greatest for the Schirmer strip, with eyes and days being significantly different (P = .03 and P = .03, respectively) for Schirmer strip Substance P. TPC was 3.8 ± 2.6 mg/mL, 3.3 ± 1.8 mg/mL, and 3.6 ± 3.0 mg/mL for F-20, F-60, and Schirmer strip techniques, respectively, with no significant difference between techniques (P = .85). Substance P concentration was 13.1 ± 14.8 ng/mL, 9.1 ± 6.1 ng/mL, and 14.9 ± 10.6 ng/mL for F-20, F-60, and Schirmer strip tears, respectively, with no significant difference between techniques (P = .57). 1DGE profile showed similar electrophoresis patterns among F-20, F-60, and basal tears. The F-60 method allows faster collection than F-20, but the latter results in better repeatability than both the F-60 and Schirmer sampling techniques. All three techniques return the same concentrations of TPC and Substance P. This indicates that tear collection using the F-20 may be more appropriate when conducting comparative analysis, whereas the F-60 may be more appropriate when more volume is required.
Comparative study of state-of-the-art myoelectric controllers for multigrasp prosthetic hands.
Segil, Jacob L; Controzzi, Marco; Weir, Richard F ff; Cipriani, Christian
2014-01-01
A myoelectric controller should provide an intuitive and effective human-machine interface that deciphers user intent in real-time and is robust enough to operate in daily life. Many myoelectric control architectures have been developed, including pattern recognition systems, finite state machines, and more recently, postural control schemes. Here, we present a comparative study of two types of finite state machines and a postural control scheme using both virtual and physical assessment procedures with seven nondisabled subjects. The Southampton Hand Assessment Procedure (SHAP) was used in order to compare the effectiveness of the controllers during activities of daily living using a multigrasp artificial hand. Also, a virtual hand posture matching task was used to compare the controllers when reproducing six target postures. The performance when using the postural control scheme was significantly better (p < 0.05) than the finite state machines during the physical assessment when comparing within-subject averages using the SHAP percent difference metric. The virtual assessment results described significantly greater completion rates (97% and 99%) for the finite state machines, but the movement time tended to be faster (2.7 s) for the postural control scheme. Our results substantiate that postural control schemes rival other state-of-the-art myoelectric controllers.
Velocities of Bone Mineral Accrual in Black and White American Children
Hui, Siu L; Perkins, Anthony J; Harezlak, Jaroslaw; Peacock, Munro; McClintock, Cindy L; Johnston, C Conrad
2010-01-01
Black adults have higher bone mass than whites in the United States, but it is not clear when black children gain bone mineral faster than white children. We performed a cohort study to compare the growth velocity of total-body bone mineral content (TBMC) between black and white children of the same sex at different ages and stages of sexual maturity. TBMC and total-body area were measured in a cohort of 188 black and white boys and girls aged 5 to 15 years annually for up to 4 years. Rates of change in TBMC and area were found to vary with age and with Tanner stage. For both TBMC and area, growth velocities between black and white children differed significantly across Tanner stages. Age-specific velocities were higher in black children during prepuberty and initial entry into puberty but reversed in subsequent Tanner stages. Despite earlier entry into each Tanner stage, black children spent only an average of only 0.2 year longer in Tanner stages II through IV, and total gain in TBMC from age 5 to 15 was not higher in whites. In conclusion, the higher bone mass in black adults compared with whites cannot be attributed to faster accrual during puberty. It is due to black children's higher rate of bone mineral accrual in prepuberty and plausibly in postpuberty. Most of the racial difference in TBMC velocity can be explained by growth in size. © 2010 American Society for Bone and Mineral Research. PMID:20200959
Inada, Yutaka; Rani, Rafiz Abdul; Naito, Yuji; Azuma, Takeshi; Itoh, Yoshito
2017-01-01
Backgrounds With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). Methods In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. Results The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1–28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Conclusions Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results. PMID:29081793
Comparison of Irrigation Times Using Gravity and High-Pressure Lavage.
Muscatelli, Stefano; Howe, Andrea; O'Hara, Nathan N; O'Toole, Robert V; Sprague, Sheila A; Slobogean, Gerard P
2017-05-01
The benefits of high-pressure pulsatile lavage for open fracture irrigation have been controversial based on conflicting experimental animal research. Recently published data definitively demonstrated that irrigation pressure does not affect the incidence of reoperation for the treatment of open fractures. However, proponents of pulsatile lavage argue a faster irrigation time is an important benefit of the high-pressure treatment. The purpose of this study was to determine the difference in irrigation time between gravity and high-pressure lavage. The experimental setup was designed to mimic clinical practice and compared mean irrigation flow times for high-pressure pulsatile lavage and gravity flow with 2 commonly used tube diameters. Each irrigation setup was tested 5 times at 3 different irrigation bag heights. Analysis of variance and Student's t tests were used to compare the mean flow times of 3 irrigation methods at each height and among the 3 heights for each irrigation method. The mean irrigation flow time in the various experimental models ranged from 161 to 243 seconds. Gravity irrigation with wide tubing was significantly faster than pulsatile lavage or gravity with narrow tubing (P<.001). Increasing irrigation bag height had only a marginal effect on the overall flow times (<9% difference). The difference in mean flow time among the testing techniques was slightly longer than 1 minute, which is unlikely to have a material impact on procedural costs, operating times, and subsequent gains in patient safety. [Orthopedics. 2017; 40(3):e413-e416.]. Copyright 2017, SLACK Incorporated.
Doeltgen, Sebastian Heinrich; Ong, Ellisa; Scholten, Ingrid; Cock, Charles; Omari, Taher
2017-11-01
Objective To quantify the effects of 2 swallowing maneuvers used in dysphagia rehabilitation-the Mendelsohn maneuver and effortful swallowing-on pharyngoesophageal function with novel, objective pressure-flow analysis. Study Design Evaluation of intervention effects in a healthy control cohort. Setting A pharyngoesophageal motility research laboratory in a tertiary education facility. Subjects Twelve young healthy subjects (9 women, 28.6 ± 7.9 years) from the general public, without swallowing impairment, volunteered to participate in this study. Methods Surface electromyography from the floor-of-mouth musculature and high-resolution impedance manometry-based pressure flow analysis were used to assess floor-of-mouth activation and pharyngoesophageal motility, respectively. Subjects each performed 10 noneffortful control swallows, Mendelsohn maneuver swallows, and effortful swallows, with a 5-mL viscous bolus. Repeated measures analyses of variance was used to compare outcome measures across conditions. Results Effortful and Mendelsohn swallows generated greater floor-of-mouth contraction ( P = .001) and pharyngeal pressure ( P < .0001) when compared with control swallows. There were no changes at the level of the upper esophageal sphincter, except for a faster opening to maximal diameter during maneuver swallows ( P = .01). The proximal esophageal contractile integral was reduced during Mendelsohn swallows ( P = .001). Conclusion Effortful and Mendelsohn maneuver swallows significantly alter the pharyngoesophageal pressure profile. Faster opening of the upper esophageal sphincter may facilitate bolus transfer during maneuver swallows; however, reduced proximal esophageal contractility during Mendelsohn maneuver swallows may impair bolus flow and aggravate dysphagic symptoms.
Gender Differences in Physical Performance Characteristics of Elite Surfers.
Parsonage, Joanna R; Secomb, Josh L; Tran, Tai T; Farley, Oliver R L; Nimphius, Sophia; Lundgren, Lina; Sheppard, Jeremy M
2017-09-01
Parsonage, JR, Secomb, JL, Tran, TT, Farley, ORL, Nimphius, S, Lundgren, L, and Sheppard, JM. Gender differences in physical performance characteristics of elite surfers. J Strength Cond Res 31(9): 2417-2422, 2017-The purpose of this study was to describe and compare the gender differences in physical performance characteristics of elite surfers. Twenty competitive female surfers (CFS) and 20 competitive male surfers (CMS) performed a battery of physical performance tests: squat jump (SJ), isometric midthigh pull (IMTP), 15-m sprint paddle, and 400-m endurance paddle during a single testing session. All performance measures were significantly different between CFS and CMS (p < 0.01). Specifically, CMS produced greater peak force production (28.5%) and jumped higher (27.7%) in the SJ and produced greater normalized peak force during the IMTP (18.9%) compared with CFS. For paddling performance, CMS were faster over 5, 10, and 15 m (12.4%, 9.7%, and 10.9%), possessed a higher peak paddling velocity (11.3%), and recorded faster paddle times over 400 m (11.8%). The results of this study suggest that CMS exhibit superior physical performance characteristics than CFS, in relation to both the lower and upper body. Strength and conditioning practitioners should therefore implement a structured and periodized program to facilitate strength qualities that underpin surfing performance for all participants, but as highlighted in the current investigation, female surfers may have a greater window for adaptation and therefore vast benefit of targeting their underdeveloped physical qualities.
Spreading Characteristics and Thrust of Jets from Asymmetric Nozzles
NASA Technical Reports Server (NTRS)
Zaman, K. B. M. Q.
1995-01-01
The spreading characteristics of jets from several asymmetric nozzles are studied in comparison to those of an axisymmetric jet, over the Mach number (M(sub J)) range of 0.3 to 1.96. The effect of tabs in two cases, the axisymmetric nozzle fitted with four tabs and a rectangular nozzle fitted with two large tabs, is also included in the comparison. Compared to the axisymmetric jet, the asymmetric jets spread only slightly faster at subsonic conditions, while at supersonic conditions, when screech occurs, they spread much faster. Screech profoundly increases the spreading of all jets. The effect varies in the different stages of screech, and the corresponding unsteady flowfield characteristics are documented via phase-averaged measurement of the fluctuating total pressure. An organization and intensification of the azimuthal vortical structures under the screeching condition is believed to be responsible for the increased spreading. Curiously, the jet from a 'lobed mixer' nozzle spreads much less at supersonic conditions compared to all other cases. This is due to the absence of screech with this nozzle. Jet spreading for the two tab configurations, on the other hand, is significantly more than any of the no-tab cases. This is true in the subsonic regime, as well as in the supersonic regime in spite of the fact that screech is essentially eliminated by the tabs. The dynamics of the streamwise vortex pairs produced by the tabs cause the most efficient jet spreading thus far observed in the study.
Bürklein, S; Benten, S; Schäfer, E
2014-05-01
To assess in a laboratory setting the amount of apically extruded debris associated with different single-file nickel-titanium instrumentation systems compared to one multiple-file rotary system. Eighty human mandibular central incisors were randomly assigned to four groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the reciprocating single-file system Reciproc, the single-file rotary systems F360 and OneShape and the multiple-file rotary Mtwo instruments. The apically extruded debris was collected and dried in pre-weighed glass vials. The amount of debris was assessed with a micro balance and statistically analysed using anova and post hoc Student-Newman-Keuls test. The time required to prepare the canals with the different instruments was also recorded. Reciproc produced significantly more debris compared to all other systems (P < 0.05). No significant difference was noted between the two single-file rotary systems and the multiple-file rotary system (P > 0.05). Instrumentation with the three single-file systems was significantly faster than with Mtwo (P < 0.05). Under the condition of this study, all systems caused apical debris extrusion. Rotary instrumentation was associated with less debris extrusion compared to reciprocal instrumentation. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Self-organization in a bimotility mixture of model microswimmers
NASA Astrophysics Data System (ADS)
Agrawal, Adyant; Babu, Sujin B.
2018-02-01
We study the cooperation and segregation dynamics in a bimotility mixture of microorganisms which swim at low Reynolds numbers via periodic deformations along the body. We employ a multiparticle collision dynamics method to simulate a two component mixture of artificial swimmers, termed as Taylor lines, which differ from each other only in the propulsion speed. The analysis reveals that a contribution of slower swimmers towards clustering, on average, is much larger as compared to the faster ones. We notice distinctive self-organizing dynamics, depending on the percentage difference in the speed of the two kinds. If this difference is large, the faster ones fragment the clusters of the slower ones in order to reach the boundary and form segregated clusters. Contrarily, when it is small, both kinds mix together at first, the faster ones usually leading the cluster and then gradually the slower ones slide out thereby also leading to segregation.
G-CSF-primed BM for allogeneic SCT: revisited.
Pessach, I; Resnick, I; Shimoni, A; Nagler, A
2015-07-01
G-SCF-mobilized PBSC (GPB) grafts have a higher cell dose and somewhat more committed progenitor cells than steady-state BM (SBM), resulting in faster engraftment and faster immunological reconstitution. On the other hand, transplant related mortality (TRM), disease-free survival (DFS) and overall survival (OS) are similar both for PB and for BM. In contrast to SBM, G-CSF-primed BM (GBM) grafts stimulate HSC proliferation, increasing cell dose and thus resulting in faster engraftment because of higher cell dose infused, or because of treatment with G-CSF. Furthermore, GBM may induce tolerance and functional modulations in donor hematopoiesis and immunity, further reducing GVHD incidence, which is already lower with SBM compared with GPB grafts. Overall, a growing body of clinical evidence suggests that GBM transplants may share the advantages of GPB transplantations, without the associated increased risk of GVHD, and might be an attractive graft source for allogeneic SCTs.
Renshaw, Andrew A; Gould, Edwin W
2017-03-01
- The College of American Pathologists requires synoptic reports for specific types of pathology reports. - To compare the accuracy and speed of information retrieval in synoptic reports of different formats. - We assessed the performance of 28 nonpathologists from 4 different types of users (cancer registrars, MDs, medical non-MDs, and nonmedical) at identifying specific information in various formatted synoptic reports, using a computerized quiz that measured both accuracy and speed. - There was no significant difference in the accuracy of data identification for any user group or in any format. While there were significant differences in raw time between users, these were eliminated when normalized times were used. Compared with the standard format of a required data element (RDE) and response on 1 line, both a list of responses without an RDE (21%, P < .001) and a paired response with more concise text (33%, P < .001) were significantly faster. In contrast, both the 2-line format (RDE header on one line, response indented on the second line) (12%, P < .001) and a report with the RDE response pairs in a random order were significantly slower (16%, P < .001). - There are significant differences in ease of use by nonpathologists between different synoptic report formats. Such information may be useful in deciding between different format options.
Immersed boundary method for Boltzmann model kinetic equations
NASA Astrophysics Data System (ADS)
Pekardan, Cem; Chigullapalli, Sruti; Sun, Lin; Alexeenko, Alina
2012-11-01
Three different immersed boundary method formulations are presented for Boltzmann model kinetic equations such as Bhatnagar-Gross-Krook (BGK) and Ellipsoidal statistical Bhatnagar-Gross-Krook (ESBGK) model equations. 1D unsteady IBM solution for a moving piston is compared with the DSMC results and 2D quasi-steady microscale gas damping solutions are verified by a conformal finite volume method solver. Transient analysis for a sinusoidally moving beam is also carried out for the different pressure conditions (1 atm, 0.1 atm and 0.01 atm) corresponding to Kn=0.05,0.5 and 5. Interrelaxation method (Method 2) is shown to provide a faster convergence as compared to the traditional interpolation scheme used in continuum IBM formulations. Unsteady damping in rarefied regime is characterized by a significant phase-lag which is not captured by quasi-steady approximations.
Pitzer, Martin; Kastirke, Gregor; Kunitski, Maksim; Jahnke, Till; Bauer, Tobias; Goihl, Christoph; Trinter, Florian; Schober, Carl; Henrichs, Kevin; Becht, Jasper; Zeller, Stefan; Gassert, Helena; Waitz, Markus; Kuhlins, Andreas; Sann, Hendrik; Sturm, Felix; Wiegandt, Florian; Wallauer, Robert; Schmidt, Lothar Ph H; Johnson, Allan S; Mazenauer, Manuel; Spenger, Benjamin; Marquardt, Sabrina; Marquardt, Sebastian; Schmidt-Böcking, Horst; Stohner, Jürgen; Dörner, Reinhard; Schöffler, Markus; Berger, Robert
2016-08-18
The absolute configuration of individual small molecules in the gas phase can be determined directly by light-induced Coulomb explosion imaging (CEI). Herein, this approach is demonstrated for ionization with a single X-ray photon from a synchrotron light source, leading to enhanced efficiency and faster fragmentation as compared to previous experiments with a femtosecond laser. In addition, it is shown that even incomplete fragmentation pathways of individual molecules from a racemic CHBrClF sample can give access to the absolute configuration in CEI. This leads to a significant increase of the applicability of the method as compared to the previously reported complete break-up into atomic ions and can pave the way for routine stereochemical analysis of larger chiral molecules by light-induced CEI. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Self-microemulsifiyng suppository formulation of β-artemether.
Gugulothu, Dalapathi; Pathak, Sulabha; Suryavanshi, Shital; Sharma, Shobhona; Patravale, Vandana
2010-09-01
Parasitic diseases are of immense global significance as around 30% of world's population experiences parasitic infections. Among these, malaria is the most life-threatening disease. Various routes of administration have been explored for delivering antimalarial actives. The present investigation aims at formulating self-microemulsifying suppositories of β-artemether with faster onset of action and prolonged effect to be administered by rectal route. These were compared with conventional polyethylene glycol suppositories with respect to melting range, rheology, texture analysis, disintegration time, self microemulsification time, particle size, and drug content. In vitro drug release was studied by using USP apparatus II. Further, the suppositories were evaluated in murine model against virulent rodent malaria parasite Plasmodium berghei wherein the developed self-microemulsifying suppositories could sustain the activity (94%) for 20 days post infection. The survival of animals was also better as compared to the conventional formulation.
Cınar, Yasin; Cingü, Abdullah Kürşat; Türkcü, Fatih Mehmet; Çınar, Tuba; Yüksel, Harun; Özkurt, Zeynep Gürsel; Çaça, Ihsan
2014-09-01
To compare outcomes of accelerated and conventional corneal cross-linking (CXL) for progressive keratoconus (KC). Patients were divided into two groups as the accelerated CXL group and the conventional CXL group. The uncorrected distant visual acuity (UDVA), corrected distant visual acuity (CDVA), refraction and keratometric values were measured preoperatively and postoperatively. The data of the two groups were compared statistically. The mean UDVA and CDVA were better at the six month postoperative when compared with preoperative values in two groups. While change in UDVA and CDVA was statistically significant in the accelerated CXL group (p = 0.035 and p = 0.047, respectively), it did not reach statistical significance in the conventional CXL group (p = 0.184 and p = 0.113, respectively). The decrease in the mean corneal power (Km) and maximum keratometric value (Kmax) were statistically significant in both groups (p = 0.012 and 0.046, respectively in the accelerated CXL group, p = 0.012 and 0.041, respectively, in the conventional CXL group). There was no statistically significant difference in visual and refractive results between the two groups (p > 0.05). Refractive and visual results of the accelerated CXL method and the conventional CXL method for the treatment of KC in short time period were similar. The accelerated CXL method faster and provide high throughput of the patients.
Computational Models Predict Larger Muscle Tissue Strains at Faster Sprinting Speeds
Fiorentino, Niccolo M; Rehorn, Michael R; Chumanov, Elizabeth S; Thelen, Darryl G; Blemker, Silvia S
2014-01-01
Introduction: Proximal biceps femoris musculotendon strain injury has been well established as a common injury among athletes participating in sports that require sprinting near or at maximum speed; however, little is known about the mechanisms that make this muscle tissue more susceptible to injury at faster speeds. Purpose: Quantify localized tissue strain during sprinting at a range of speeds. Methods: Biceps femoris long head (BFlh) musculotendon dimensions of 14 athletes were measured on magnetic resonance (MR) images and used to generate a finite element computational model. The model was first validated through comparison with previous dynamic MR experiments. After validation, muscle activation and muscle-tendon unit length change were derived from forward dynamic simulations of sprinting at 70%, 85% and 100% maximum speed and used as input to the computational model simulations. Simulations ran from mid-swing to foot contact. Results: The model predictions of local muscle tissue strain magnitude compared favorably with in vivo tissue strain measurements determined from dynamic MR experiments of the BFlh. For simulations of sprinting, local fiber strain was non-uniform at all speeds, with the highest muscle tissue strain where injury is often observed (proximal myotendinous junction). At faster sprinting speeds, increases were observed in fiber strain non-uniformity and peak local fiber strain (0.56, 0.67 and 0.72, for sprinting at 70%, 85% and 100% maximum speed). A histogram of local fiber strains showed that more of the BFlh reached larger local fiber strains at faster speeds. Conclusions: At faster sprinting speeds, peak local fiber strain, fiber strain non-uniformity and the amount of muscle undergoing larger strains are predicted to increase, likely contributing to the BFlh muscle’s higher injury susceptibility at faster speeds. PMID:24145724
NASA Astrophysics Data System (ADS)
Pandiyan, Vimal Prabhu; Khare, Kedar; John, Renu
2017-09-01
A constrained optimization approach with faster convergence is proposed to recover the complex object field from a near on-axis digital holography (DH). We subtract the DC from the hologram after recording the object beam and reference beam intensities separately. The DC-subtracted hologram is used to recover the complex object information using a constrained optimization approach with faster convergence. The recovered complex object field is back propagated to the image plane using the Fresnel back-propagation method. The results reported in this approach provide high-resolution images compared with the conventional Fourier filtering approach and is 25% faster than the previously reported constrained optimization approach due to the subtraction of two DC terms in the cost function. We report this approach in DH and digital holographic microscopy using the U.S. Air Force resolution target as the object to retrieve the high-resolution image without DC and twin image interference. We also demonstrate the high potential of this technique in transparent microelectrode patterned on indium tin oxide-coated glass, by reconstructing a high-resolution quantitative phase microscope image. We also demonstrate this technique by imaging yeast cells.
Oxo-exchange of gas-phase uranyl, neptunyl, and plutonyl with water and methanol.
Lucena, Ana F; Odoh, Samuel O; Zhao, Jing; Marçalo, Joaquim; Schreckenbach, Georg; Gibson, John K
2014-02-17
A challenge in actinide chemistry is activation of the strong bonds in the actinyl ions, AnO2(+) and AnO2(2+), where An = U, Np, or Pu. Actinyl activation in oxo-exchange with water in solution is well established, but the exchange mechanisms are unknown. Gas-phase actinyl oxo-exchange is a means to probe these processes in detail for simple systems, which are amenable to computational modeling. Gas-phase exchange reactions of UO2(+), NpO2(+), PuO2(+), and UO2(2+) with water and methanol were studied by experiment and density functional theory (DFT); reported for the first time are experimental results for UO2(2+) and for methanol exchange, as well as exchange rate constants. Key findings are faster exchange of UO2(2+) versus UO2(+) and faster exchange with methanol versus water; faster exchange of UO2(+) versus PuO2(+) was quantified. Computed potential energy profiles (PEPs) are in accord with the observed kinetics, validating the utility of DFT to model these exchange processes. The seemingly enigmatic result of faster exchange for uranyl, which has the strongest oxo-bonds, may reflect reduced covalency in uranyl as compared with plutonyl.
USDA-ARS?s Scientific Manuscript database
Due to increasing financial and environmental concerns, governmental rules, regulations and incentives alternative energy sources are soon expected to grow at a much faster pace than conventional sources of energy. However, the current body of research providing comparative decision making models fo...
A preliminary study of the effect of guaiphenesin on mucociliary clearance from the human lung
Thomson, M. L.; Pavia, D.; McNicol, M. W.
1973-01-01
Thomson, M. L., Pavia, D., and McNicol, M. W. (1973).Thorax, 28, 742-747. A preliminary study of the effect of guaiphenesin on mucociliary clearance from the human lung. The effect of guaiphenesin (administered as Robitussin1) on mucociliary clearance has been assessed in 15 subjects from the rate of removal from the lung of previously inhaled radioactive tracer particles. The guaiphenesin was compared with a positive control preparation consisting of the guaiphenesin vehicle only in two double-blind crossover trials. The first trial examined eight aged `healthy' volunteer subjects and the second trial examined seven chronic bronchitic patients. Sequential gamma counts were made from the whole lung by scintillation counters for 6 hours after inhalation and the chest was also scanned rectilinearly. In the first 5 hours after inhalation the mean rate of removal of particles and therefore of secretions was faster after guaiphenesin than after the control preparation. This difference was not statistically significant in the healthy volunteers but achieved significance (P <0·05) in the chronic bronchitic patients. Lung scans after inhaling the tracer aerosol indicated that on average the initial penetration of the particles into the lung was similar in the guaiphenesin and control runs. The faster clearance after guaiphenesin was unlikely to be due to bulk movements of mucus caused by coughing since the mean frequency of coughing during the experiment was somewhat less after the drug. PMID:4595814
The macular photostress test in diabetes, glaucoma, and cataract
NASA Astrophysics Data System (ADS)
Baptista, António M. G.; Sousa, Raul A. R. C.; Rocha, Filomena A. S. Q.; Fernandes, Paula Sepúlveda; Macedo, António F.
2013-11-01
Purpose. The photostress recovery time test (PSRT) has been widely reported as a helpful screening clinical tool. However, the poor standardization of its measurement technique remains to be a limitation among clinicians. The purpose of this study is to apply a recommended clinical technique to measure the PSRT in some of the most commons eye diseases to ascertain whether these diseases affect the PSRT values. Methods. One hundred and one controls and 105 patients, with diagnosed diabetes (without visible signs of diabetic retinopathy), primary open angle glaucoma (POAG) or cataracts underwent photostress testing. The test was performed with a direct ophthalmoscope for illuminating the macula for 30 seconds. Participants belonged to three age classes: A, B and C; and were divided into four groups: control, diabetic, POAG and cataract. The age range for A, B and C classes were respectively 43-54, 55-64 and 65-74 years. The groups were also further compared within each age class. In addition, the influence of age on PSRT was evaluated using the control group. Results. Results demonstrate that PSRT changes with age (p<0.02). In class A, diabetic group had a faster PSRT than control group, (mean +/- standard deviation) 20.22+/-7.51 and 26.14+/-8.34 seconds. The difference between these groups was statistical significant (t-test, p=0.012). Cataract and POAG groups did not affect the PSRT significantly. Conclusions. The technique used for the Photostress showed that diabetics, younger than 54 years, may have faster PSRT and that, aging delays PSRT.
Ocular Vestibular Evoked Myogenic Potentials in Response to Three Test Positions and Two Frequencies
Todai, Janvi K.; Congdon, Sharon L.; Sangi-Haghpeykar, Haleh; Cohen, Helen S.
2014-01-01
Objective To determine how eye closure, test positions, and stimulus frequencies influence ocular vestibular evoked myogenic potentials. Study Design This study used a within-subjects repeated measures design. Methods Twenty asymptomatic subjects were each tested on ocular vestibular evoked myogenic potentials in three head/eye conditions at 500 Hz and 1000 Hz using air-conducted sound: 1) Sitting upright, head erect, eyes open, looking up. 2) Lying supine, neck flexed 30 degrees, eyes open and looking up. 3) Lying supine, neck flexed 30 degrees, eyes closed and relaxed. Four dependent variables measured were n10, p16, amplitude, and threshold. Results The supine position/ eyes open was comparable to sitting/ eyes open and better than supine/ eyes closed. Eyes closed resulted in lower amplitude, higher threshold, and prolonged latency. Significantly fewer subjects provided responses with eyes closed than with eyes open. No significant differences were found between both eyes open conditions. Both n10 and p16 were lower at 1000 Hz than at 500 Hz. Amplitude and threshold were higher at 1000 Hz than at 500 Hz. Conclusion Supine eyes open is a reliable alternative to sitting eyes open in patients who cannot maintain a seated position. Testing at 1000 Hz provides a larger response with a faster onset that fatigues faster than at 500 Hz. The increased variability and decreased response in the eyes closed position suggest that the eyes closed position is not reliable. PMID:24178911
Both anodal and cathodal transcranial direct current stimulation improves semantic processing.
Brückner, Sabrina; Kammer, Thomas
2017-02-20
Transcranial direct current stimulation (tDCS) is a common method to modulate cortical activity. Anodal tDCS is usually associated with an enhancement of the stimulated brain area, whereas cathodal tDCS is often described as inhibitory brain stimulation method. Our aim was to investigate whether this canonical assumption derived from the motor system could be transferred to the semantic system. Three groups with 20 healthy subjects each were stimulated at Wernicke's area with either anodal, cathodal or sham tDCS. Subsequently, they performed a simple lexical decision task for a duration of about 25min. Subjects receiving anodal tDCS revealed faster reaction times (RTs) compared to the sham group, although not reaching statistical significance. Surprisingly, in the cathodal group RTs were decreased significantly. All subjects were faster in the second half of the task, but the tDCS-induced improvement lasted for the entire duration of the task. Error rates were not influenced by tDCS, neither were RTs in a choice reaction time task. Thus, both anodal and cathodal tDCS applied to Wernicke's area improved semantic processing. Recently, a meta-analysis revealed that the canonical anodal excitation and cathodal inhibition assumption is observed rarely in cognitive studies. In particular, an inhibitory effect of cathodal tDCS on cognition is rare. Our findings thus support the speculation, that especially language functions could be somewhat 'immune' to cathodal inhibition. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Freeman, Benjamin G; Montgomery, Graham A; Schluter, Dolph
2017-09-01
Plasticity is often thought to accelerate trait evolution and speciation. For example, plasticity in birdsong may partially explain why clades of song learners are more diverse than related clades with innate song. This "song learning" hypothesis predicts that (1) differences in song traits evolve faster in song learners, and (2) behavioral discrimination against allopatric song (a proxy for premating reproductive isolation) evolves faster in song learners. We tested these predictions by analyzing acoustic traits and conducting playback experiments in allopatric Central American sister pairs of song learning oscines (N = 42) and nonlearning suboscines (N = 27). We found that nonlearners evolved mean acoustic differences slightly faster than did leaners, and that the mean evolutionary rate of song discrimination was 4.3 times faster in nonlearners than in learners. These unexpected results may be a consequence of significantly greater variability in song traits in song learners (by 54-79%) that requires song-learning oscines to evolve greater absolute differences in song before achieving the same level of behavioral song discrimination as nonlearning suboscines. This points to "a downside of learning" for the evolution of species discrimination, and represents an important example of plasticity reducing the rate of evolution and diversification by increasing variability. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.
Kamesh Iyer, Srikant; Tasdizen, Tolga; Likhite, Devavrat; DiBella, Edward
2016-01-01
Purpose: Rapid reconstruction of undersampled multicoil MRI data with iterative constrained reconstruction method is a challenge. The authors sought to develop a new substitution based variable splitting algorithm for faster reconstruction of multicoil cardiac perfusion MRI data. Methods: The new method, split Bregman multicoil accelerated reconstruction technique (SMART), uses a combination of split Bregman based variable splitting and iterative reweighting techniques to achieve fast convergence. Total variation constraints are used along the spatial and temporal dimensions. The method is tested on nine ECG-gated dog perfusion datasets, acquired with a 30-ray golden ratio radial sampling pattern and ten ungated human perfusion datasets, acquired with a 24-ray golden ratio radial sampling pattern. Image quality and reconstruction speed are evaluated and compared to a gradient descent (GD) implementation and to multicoil k-t SLR, a reconstruction technique that uses a combination of sparsity and low rank constraints. Results: Comparisons based on blur metric and visual inspection showed that SMART images had lower blur and better texture as compared to the GD implementation. On average, the GD based images had an ∼18% higher blur metric as compared to SMART images. Reconstruction of dynamic contrast enhanced (DCE) cardiac perfusion images using the SMART method was ∼6 times faster than standard gradient descent methods. k-t SLR and SMART produced images with comparable image quality, though SMART was ∼6.8 times faster than k-t SLR. Conclusions: The SMART method is a promising approach to reconstruct good quality multicoil images from undersampled DCE cardiac perfusion data rapidly. PMID:27036592
Leaf breakdown in streams differing in catchment land use
Paul, M.J.; Meyer, J.L.; Couch, C.A.
2006-01-01
1. The impact of changes in land use on stream ecosystem function is poorly understood. We studied leaf breakdown, a fundamental process of stream ecosystems, in streams that represent a range of catchment land use in the Piedmont physiographic province of the south-eastern United States. 2. We placed bags of chalk maple (Acer barbatum) leaves in similar-sized streams in 12 catchments of differing dominant land use: four forested, three agricultural, two suburban and three urban catchments. We measured leaf mass, invertebrate abundance and fungal biomass in leaf bags over time. 3. Leaves decayed significantly faster in agricultural (0.0465 day-1) and urban (0.0474 day-1) streams than in suburban (0.0173 day-1) and forested (0.0100 day-1) streams. Additionally, breakdown rates in the agricultural and urban streams were among the fastest reported for deciduous leaves in any stream. Nutrient concentrations in agricultural streams were significantly higher than in any other land-use type. Fungal biomass associated with leaves was significantly lower in urban streams; while shredder abundance in leaf bags was significantly higher in forested and agricultural streams than in suburban and urban streams. Storm runoff was significantly higher in urban and suburban catchments that had higher impervious surface cover than forested or agricultural catchments. 4. We propose that processes accelerating leaf breakdown in agricultural and urban streams were not the same: faster breakdown in agricultural streams was due to increased biological activity as a result of nutrient enrichment, whereas faster breakdown in urban streams was a result of physical fragmentation resulting from higher storm runoff. ?? 2006 The Authors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Memariani, Hamed; Shahbazzadeh, Delavar; Sabatier, Jean-Marc
Antimicrobial peptides are attractive candidates for developing novel therapeutic agents, since they are lethal to a broad spectrum of pathogens and have a unique low tendency for resistance development. In this study, mechanism of action and in vitro anti-pseudomonal activity of previously designed short hybrid antimicrobial peptide PV3 were investigated. Compared to ceftazidime, PV3 had not only higher antibacterial activity but also faster bactericidal activity. PV3 reduced biofilm biomass and viability of biofilm embedded bacteria in a concentration-dependent manner. Although the antimicrobial activity of PV3 was reduced in Mueller-Hinton broth (MHB) containing human serum, it was still active enough to eradicationmore » of bacteria at low concentrations. Compared with standard condition (MHB only), there was no significant decrease in antibacterial activity of PV3 against P. aeruginosa strains under 150 mM NaCl (p = 0.615) and 1 mM MgCl{sub 2} (p = 0.3466). Fluorescence microscopy and field emission scanning electron microscopy further indicated that PV3 killed bacteria by disrupting the cell membrane. Since PV3 has potent anti-pseudomonal activity and has little cytotoxicity in vitro, it seems plausible that the peptide should be further investigated with animal studies to support future pharmacological formulations and potential topical applications. - Highlights: • PV3 killed Pseudomonas aeruginosa by membrane-disrupting mechanism. • PV3 reduced biofilm biomass and viability of biofilm embedded bacteria in a concentration-dependent manner. • Short hybrid antimicrobial peptide PV3 exhibited higher and faster bactericidal activity comparing to ceftazidime.« less
Maie, Takashi; Wilson, Megan P; Schoenfuss, Heiko L; Blob, Richard W
2009-03-01
Distributions of Hawaiian stream fishes are typically interrupted by waterfalls that divide streams into multiple segments. Larvae hatch upstream, are flushed into the ocean, and must climb these waterfalls to reach adult habitats when returning back to freshwater as part of an amphidromous life cycle. Stream surveys and studies of climbing performance show that Lentipes concolor Gill can reach fast-flowing upper stream segments but that Awaous guamensis Valenciennes reaches only slower, lower stream segments. Gut content analyses for these two species indicate considerable overlap in diet, suggesting that feeding kinematics and performance of these two species might be comparable. Alternatively, feeding kinematics and performance of these species might be expected to differ in relation to the different flow regimes in their habitat (feeding in faster stream currents for L. concolor versus in slower currents for A. guamensis). To test these alternative hypotheses, we compared food capturing kinematics and performance during suction feeding behaviors of A. guamensis and L. concolor using morphological data and high-speed video. Lentipes concolor showed both a significantly larger gape angle and faster jaw opening than A. guamensis. Geometric models calculated that despite the inverse relationship of gape size and suction pressure generation, the fast jaw motions of L. concolor allow it to achieve higher pressure differentials than A. guamensis. Such elevated suction pressure would enhance the ability of L. concolor to successfully capture food in the fast stream reaches it typically inhabits. Differences in jaw morphology may contribute to these differences in performance, as the lever ratio for jaw opening is about 10% lower in L. concolor compared with A. guamensis, suiting the jaws of L. concolor better for fast opening. Copyright 2008 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Helser, Thomas E.; Colman, Jamie R.; Anderl, Delsa M.; Kastelle, Craig R.
2017-01-01
Saffron cod (Eleginus gracilis) and Arctic cod (Boreogadus saida) are two circumpolar gadids that serve as critically important species responsible for energy transfer in Arctic food webs of the northern Bering and Chukchi Seas. To understand the potential effects of sea ice loss and warming temperatures on these species' basic life history, information such as growth is needed. Yet to date, limited effort has been dedicated to the study of their growth dynamics. Based on a large sample of otoliths collected in the first comprehensive ecosystem integrated survey in the northern Bering and Chukchi Seas, procedures were developed to reliably estimate age from otolith growth zones and were used to study the growth dynamics of saffron and Arctic cod. Annual growth zone assignment was validated using oxygen isotope signatures in otoliths and otolith morphology analyzed and compared between species. Saffron cod attained larger asymptotic sizes (L∞=363 mm) and achieved their maximum size at a faster rate (K=0.378) than Arctic cod (L∞=209 mm; K=0.312). For both species, regional differences in growth were found (p<0.01). Saffron cod grew to a significantly larger size at age in the northern Bering Sea when compared to the Chukchi Sea, particularly at younger ages. Arctic cod grew to smaller asymptotic size but at faster rates in the more northerly central (L∞=197 mm;K=0.324) and southern Chukchi Sea (L∞=221 mm;K=0.297) when compared to the northern Bering Sea (L∞=266 mm;K=0.171), suggesting a possible cline in growth rates with more northerly latitudes. Comparison of growth to two periods separated by 30 years indicate that both species exhibited a decline in maximum size accompanied by higher instantaneous growth rates in more recent years.
Survival of Spoilage and Pathogenic Microorganisms on Cardboard and Plastic Packaging Materials
Siroli, Lorenzo; Patrignani, Francesca; Serrazanetti, Diana I.; Chiavari, Cristiana; Benevelli, Marzia; Grazia, Luigi; Lanciotti, Rosalba
2017-01-01
The aim of this work was to study the interaction of corrugated and plastic materials with pathogenic and spoiling microorganisms frequently associated to fresh produce. The effect of the two packaging materials on the survival during the storage of microorganisms belonging to the species Escherichia coli, Listeria monocytogenes, Salmonella enteritidis, Saccharomyces cerevisiae, Lactobacillus plantarum, Pseudomonas fluorescens, and Aspergillus flavus was studied through traditional plate counting and scanning electron microscopy (SEM). The results obtained showed that cardboard materials, if correctly stored, reduced the potential of packaging to cross-contaminate food due to a faster viability loss by spoilage and pathogenic microorganisms compared to the plastic ones. In fact, the cell loads of the pathogenic species considered decreased over time independently on the inoculation level and packaging material used. However, the superficial viability losses were significantly faster in cardboard compared to plastic materials. The same behavior was observed for the spoilage microorganisms considered. The SEM microphotographs indicate that the reduction of superficial contamination on cardboard surfaces was due to the entrapping of the microbial cells within the fibers and the pores of this material. In addition, SEM data showed that the entrapped cells were subjected to more or less rapid lyses, depending on the species, due to the absence of water and nutrients, with the exception of molds. The latter spoilers were able to proliferate inside the cardboard fibers only when the absorption of water was not prevented during the storage. In conclusion, the findings of this work showed the reduction of cross-contamination potential of corrugated compared to plastic packaging materials used in fruit and vegetable sector. However, the findings outlined the importance of hygiene and low humidity during cardboard storage to prevent the mold growth on packaging. PMID:29312271
Biomechanical implications of walking with indigenous footwear
Willems, Catherine; Stassijns, Gaetane; Cornelis, Wim; D'Août, Kristiaan
2017-01-01
Abstract Objectives This study investigates biomechanical implications of walking with indigenous “Kolhapuri” footwear compared to barefoot walking among a population of South Indians. Materials and methods Ten healthy adults from South India walked barefoot and indigenously shod at voluntary speed on an artificial substrate. The experiment was repeated outside, on a natural substrate. Data were collected from (1) a heel‐mounted 3D‐accelerometer recording peak impact at heel contact, (2) an ankle‐mounted 3D‐goniometer (plantar/dorsiflexion and inversion/eversion), and (3) sEMG electrodes at the m. tibialis anterior and the m. gastrocnemius medialis. Results Data show that the effect of indigenous footwear on the measured variables, compared to barefoot walking, is relatively small and consistent between substrates (even though subjects walked faster on the natural substrate). Walking barefoot, compared to shod walking yields higher impact accelerations, but the differences are small and only significant for the artificial substrate. The main rotations of the ankle joint are mostly similar between conditions. Only the shod condition shows a faster ankle rotation over the rapid eversion motion on the natural substrate. Maximal dorsiflexion in late stance differs between the footwear conditions on an artificial substrate, with the shod condition involving a less dorsiflexed ankle, and the plantar flexion at toe‐off is more extreme when shod. Overall the activity pattern of the external foot muscles is similar. Discussion The indigenous footwear studied (Kolhapuri) seems to alter foot biomechanics only in a subtle way. While offering some degree of protection, walking in this type of footwear resembles barefoot gait and this type of indigenous footwear might be considered “minimal”. PMID:28101944
Biomechanical implications of walking with indigenous footwear.
Willems, Catherine; Stassijns, Gaetane; Cornelis, Wim; D'Août, Kristiaan
2017-04-01
This study investigates biomechanical implications of walking with indigenous "Kolhapuri" footwear compared to barefoot walking among a population of South Indians. Ten healthy adults from South India walked barefoot and indigenously shod at voluntary speed on an artificial substrate. The experiment was repeated outside, on a natural substrate. Data were collected from (1) a heel-mounted 3D-accelerometer recording peak impact at heel contact, (2) an ankle-mounted 3D-goniometer (plantar/dorsiflexion and inversion/eversion), and (3) sEMG electrodes at the m. tibialis anterior and the m. gastrocnemius medialis. Data show that the effect of indigenous footwear on the measured variables, compared to barefoot walking, is relatively small and consistent between substrates (even though subjects walked faster on the natural substrate). Walking barefoot, compared to shod walking yields higher impact accelerations, but the differences are small and only significant for the artificial substrate. The main rotations of the ankle joint are mostly similar between conditions. Only the shod condition shows a faster ankle rotation over the rapid eversion motion on the natural substrate. Maximal dorsiflexion in late stance differs between the footwear conditions on an artificial substrate, with the shod condition involving a less dorsiflexed ankle, and the plantar flexion at toe-off is more extreme when shod. Overall the activity pattern of the external foot muscles is similar. The indigenous footwear studied (Kolhapuri) seems to alter foot biomechanics only in a subtle way. While offering some degree of protection, walking in this type of footwear resembles barefoot gait and this type of indigenous footwear might be considered "minimal". © 2017 The Authors American Journal of Physical Anthropology Published by Wiley Periodicals, Inc.
A novel constructive-optimizer neural network for the traveling salesman problem.
Saadatmand-Tarzjan, Mahdi; Khademi, Morteza; Akbarzadeh-T, Mohammad-R; Moghaddam, Hamid Abrishami
2007-08-01
In this paper, a novel constructive-optimizer neural network (CONN) is proposed for the traveling salesman problem (TSP). CONN uses a feedback structure similar to Hopfield-type neural networks and a competitive training algorithm similar to the Kohonen-type self-organizing maps (K-SOMs). Consequently, CONN is composed of a constructive part, which grows the tour and an optimizer part to optimize it. In the training algorithm, an initial tour is created first and introduced to CONN. Then, it is trained in the constructive phase for adding a number of cities to the tour. Next, the training algorithm switches to the optimizer phase for optimizing the current tour by displacing the tour cities. After convergence in this phase, the training algorithm switches to the constructive phase anew and is continued until all cities are added to the tour. Furthermore, we investigate a relationship between the number of TSP cities and the number of cities to be added in each constructive phase. CONN was tested on nine sets of benchmark TSPs from TSPLIB to demonstrate its performance and efficiency. It performed better than several typical Neural networks (NNs), including KNIES_TSP_Local, KNIES_TSP_Global, Budinich's SOM, Co-Adaptive Net, and multivalued Hopfield network as wall as computationally comparable variants of the simulated annealing algorithm, in terms of both CPU time and accuracy. Furthermore, CONN converged considerably faster than expanding SOM and evolved integrated SOM and generated shorter tours compared to KNIES_DECOMPOSE. Although CONN is not yet comparable in terms of accuracy with some sophisticated computationally intensive algorithms, it converges significantly faster than they do. Generally speaking, CONN provides the best compromise between CPU time and accuracy among currently reported NNs for TSP.
Sherry, Christina L; Kim, Stephanie S; Freund, Gregory G
2009-06-01
The proinflammatory consequences of obesity are thought to be due, in part, to macrophage infiltration into adipose tissue. There are, however, potential antiinflammatory consequences of obesity that include obesity-associated up-regulation of IL-1 receptor antagonist (IL-1RA). Here we show that obesity-associated up-regulation of IL-1RA speeds recovery from hypoxia. We found that high-fat diet-fed (HFD) mice recovered from acute hypoxia 5 times faster than normal-diet-fed (ND) mice. HFD mice had a 10-fold increase in serum IL-1RA when compared with ND mice. White adipose tissue (WAT) was a significant source of IL-RA, generating 330 +/- 77 pg/mg protein in HFD mice as compared with 15 +/- 5 pg/mg protein in ND mice. Peritoneal macrophages isolated from HFD mice showed little difference in IL-1RA production when compared with ND mice, but WAT macrophages from HFD mice generated 11-fold more IL-1RA than those from ND mice. When ND mice were given an ip transfer of the stromal vascular fraction portion of WAT from HFD mice, serum IL-1RA increased 836% and recovery from acute hypoxia was faster than in mice that did not receive a stromal vascular fraction transfer. To determine whether IL-1RA was important to this accelerated recovery, ND mice were administered exogenous IL-1RA prior to hypoxia, and their recovery matched that of HFD mice. Inversely, when IL-1RA was immunoabsorbed in HFD mice with IL-1RA antiserum, recovery from acute hypoxia was attenuated. Taken together these data demonstrate that HFD-induced obesity speeds recovery from hypoxia due to obesity-associated up-regulation of IL-1RA.
Sherry, Christina L.; Kim, Stephanie S.; Freund, Gregory G.
2009-01-01
The proinflammatory consequences of obesity are thought to be due, in part, to macrophage infiltration into adipose tissue. There are, however, potential antiinflammatory consequences of obesity that include obesity-associated up-regulation of IL-1 receptor antagonist (IL-1RA). Here we show that obesity-associated up-regulation of IL-1RA speeds recovery from hypoxia. We found that high-fat diet-fed (HFD) mice recovered from acute hypoxia 5 times faster than normal-diet-fed (ND) mice. HFD mice had a 10-fold increase in serum IL-1RA when compared with ND mice. White adipose tissue (WAT) was a significant source of IL-RA, generating 330 ± 77 pg/mg protein in HFD mice as compared with 15 ± 5 pg/mg protein in ND mice. Peritoneal macrophages isolated from HFD mice showed little difference in IL-1RA production when compared with ND mice, but WAT macrophages from HFD mice generated 11-fold more IL-1RA than those from ND mice. When ND mice were given an ip transfer of the stromal vascular fraction portion of WAT from HFD mice, serum IL-1RA increased 836% and recovery from acute hypoxia was faster than in mice that did not receive a stromal vascular fraction transfer. To determine whether IL-1RA was important to this accelerated recovery, ND mice were administered exogenous IL-1RA prior to hypoxia, and their recovery matched that of HFD mice. Inversely, when IL-1RA was immunoabsorbed in HFD mice with IL-1RA antiserum, recovery from acute hypoxia was attenuated. Taken together these data demonstrate that HFD-induced obesity speeds recovery from hypoxia due to obesity-associated up-regulation of IL-1RA. PMID:19213834
Risk perception influences athletic pacing strategy.
Micklewright, Dominic; Parry, David; Robinson, Tracy; Deacon, Greg; Renfree, Andrew; St Clair Gibson, Alan; Matthews, William J
2015-05-01
The objective of this study is to examine risk taking and risk perception associations with perceived exertion, pacing, and performance in athletes. Two experiments were conducted in which risk perception was assessed using the domain-specific risk taking (DOSPERT) scale in 20 novice cyclists (experiment 1) and 32 experienced ultramarathon runners (experiment 2). In experiment 1, participants predicted their pace and then performed a 5-km maximum effort cycling time trial on a calibrated Kingcycle mounted bicycle. Split times and perceived exertion were recorded every kilometer. In experiment 2, each participant predicted their split times before running a 100-km ultramarathon. Split times and perceived exertion were recorded at seven checkpoints. In both experiments, higher and lower risk perception groups were created using median split of DOSPERT scores. In experiment 1, pace during the first kilometer was faster among lower risk perceivers compared with higher risk perceivers (t(18) = 2.0, P = 0.03) and faster among higher risk takers compared with lower risk takers (t(18) = 2.2, P = 0.02). Actual pace was slower than predicted pace during the first kilometer in both the higher risk perceivers (t(9) = -4.2, P = 0.001) and lower risk perceivers (t(9) = -1.8, P = 0.049). In experiment 2, pace during the first 36 km was faster among lower risk perceivers compared with higher risk perceivers (t(16) = 2.0, P = 0.03). Irrespective of risk perception group, actual pace was slower than predicted pace during the first 18 km (t(16) = 8.9, P < 0.001) and from 18 to 36 km (t(16) = 4.0, P < 0.001). In both experiments, there was no difference in performance between higher and lower risk perception groups. Initial pace is associated with an individual's perception of risk, with low perceptions of risk being associated with a faster starting pace. Large differences between predicted and actual pace suggest that the performance template lacks accuracy, perhaps indicating greater reliance on momentary pacing decisions rather than preplanned strategy.
Agarkar, Smita; Hurt, Stephen W; Young, Robert C
2018-07-01
We reviewed studies that reported speed of antidepressant response to electroconvulsive therapy (ECT) in both bipolar depression (BPD) and major depressive disorder (MDD). We identified English language reports allowing this comparison. Ten studies met our criteria. Four reported significantly faster response in BPD and in one there was trend for faster response. None reported evidence for slower response in BPD. The findings support further study of speed of response to ECT in BPD. Copyright © 2018 Elsevier B.V. All rights reserved.
Comparison of Systemic and Topical Hypericum Perforatum on Diabetic Surgical Wounds.
Altıparmak, Mehmet; Eskitaşçıoğlu, Teoman
2018-02-01
Surgical wounds in diabetic patients still remain a problem till the present day. As a common plant found around the world, Hypericum perforatum L. (Hypericaceae) is traditionally prepared as an oily extract and used as a folk remedy for various diseases such as wounds, burns, cuts, etc. This study aims to evaluate the effect of St. John's wort (Hypericum perforatum) on problematic wounds while comparing oral and topical applications. Incisional and excisional wound models were made on the dorsal regions of 54 diabetic Spraque-Dawley rats. The rats were divided into the following six groups (n = 9): Group 1: control, Group 2: diabetic, Group 3: diabetic oral Hypericum perforatum, Group 4: diabetic topical Hypericum perforatum, Group 5: diabetic oral olive oil, and Group 6: diabetic topical olive oil. Groups 3 and 4 had significantly higher tensile strength, tissue hydroxyproline concentration, and collagen density compared with Group 2. Inflammatory cell density and collagen density on day 3 were significantly higher in Groups 3 and 6 compared with Group 2. On day 21, Groups 3 and 6 had significantly higher fibroblastic activity compared with Group 2. This study has proved that oral St. John's wort has more positive effects on problematic wounds compared with topical St. John's wort and olive oil, which is a vehicle. Hypericum perforatum results with faster inflammatory response and better healing. These results could be an addition to literature about the clinical usage of Hypericum perforatum on diabetic wounds.
Altahawi, Faysal F; Blount, Kevin J; Morley, Nicholas P; Raithel, Esther; Omar, Imran M
2017-01-01
To compare a faster, new, high-resolution accelerated 3D-fast-spin-echo (3D-FSE) acquisition sequence (CS-SPACE) to traditional 2D and high-resolution 3D sequences for knee 3-T magnetic resonance imaging (MRI). Twenty patients received knee MRIs that included routine 2D (T1, PD ± FS, T2-FS; 0.5 × 0.5 × 3 mm 3 ; ∼10 min), traditional 3D FSE (SPACE-PD-FS; 0.5 × 0.5 × 0.5 mm 3 ; ∼7.5 min), and accelerated 3D-FSE prototype (CS-SPACE-PD-FS; 0.5 × 0.5 × 0.5 mm 3 ; ∼5 min) acquisitions on a 3-T MRI system (Siemens MAGNETOM Skyra). Three musculoskeletal radiologists (MSKRs) prospectively and independently reviewed the studies with graded surveys comparing image and diagnostic quality. Tissue-specific signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were also compared. MSKR-perceived diagnostic quality of cartilage was significantly higher for CS-SPACE than for SPACE and 2D sequences (p < 0.001). Assessment of diagnostic quality of menisci and synovial fluid was higher for CS-SPACE than for SPACE (p < 0.001). CS-SPACE was not significantly different from SPACE but had lower assessments than 2D sequences for evaluation of bones, ligaments, muscles, and fat (p ≤ 0.004). 3D sequences had higher spatial resolution, but lower overall assessed contrast (p < 0.001). Overall image quality from CS-SPACE was assessed as higher than SPACE (p = 0.007), but lower than 2D sequences (p < 0.001). Compared to SPACE, CS-SPACE had higher fluid SNR and CNR against all other tissues (all p < 0.001). The CS-SPACE prototype allows for faster isotropic acquisitions of knee MRIs over currently used protocols. High fluid-to-cartilage CNR and higher spatial resolution over routine 2D sequences may present a valuable role for CS-SPACE in the evaluation of cartilage and menisci.
HIA: a genome mapper using hybrid index-based sequence alignment.
Choi, Jongpill; Park, Kiejung; Cho, Seong Beom; Chung, Myungguen
2015-01-01
A number of alignment tools have been developed to align sequencing reads to the human reference genome. The scale of information from next-generation sequencing (NGS) experiments, however, is increasing rapidly. Recent studies based on NGS technology have routinely produced exome or whole-genome sequences from several hundreds or thousands of samples. To accommodate the increasing need of analyzing very large NGS data sets, it is necessary to develop faster, more sensitive and accurate mapping tools. HIA uses two indices, a hash table index and a suffix array index. The hash table performs direct lookup of a q-gram, and the suffix array performs very fast lookup of variable-length strings by exploiting binary search. We observed that combining hash table and suffix array (hybrid index) is much faster than the suffix array method for finding a substring in the reference sequence. Here, we defined the matching region (MR) is a longest common substring between a reference and a read. And, we also defined the candidate alignment regions (CARs) as a list of MRs that is close to each other. The hybrid index is used to find candidate alignment regions (CARs) between a reference and a read. We found that aligning only the unmatched regions in the CAR is much faster than aligning the whole CAR. In benchmark analysis, HIA outperformed in mapping speed compared with the other aligners, without significant loss of mapping accuracy. Our experiments show that the hybrid of hash table and suffix array is useful in terms of speed for mapping NGS sequencing reads to the human reference genome sequence. In conclusion, our tool is appropriate for aligning massive data sets generated by NGS sequencing.
Imposed Faster and Slower Walking Speeds Influence Gait Stability Differently in Parkinson Fallers.
Cole, Michael H; Sweeney, Matthew; Conway, Zachary J; Blackmore, Tim; Silburn, Peter A
2017-04-01
To evaluate the effect of imposed faster and slower walking speeds on postural stability in people with Parkinson disease (PD). Cross-sectional cohort study. General community. Patients with PD (n=84; 51 with a falls history; 33 without) and age-matched controls (n=82) were invited to participate via neurology clinics and preexisting databases. Of those contacted, 99 did not respond (PD=36; controls=63) and 27 were not interested (PD=18; controls=9). After screening, a further 10 patients were excluded; 5 had deep brain stimulation surgery and 5 could not accommodate to the treadmill. The remaining patients (N=30) completed all assessments and were subdivided into PD fallers (n=10), PD nonfallers (n=10), and age-matched controls (n=10) based on falls history. Not applicable. Three-dimensional accelerometers assessed head and trunk accelerations and allowed calculation of harmonic ratios and root mean square (RMS) accelerations to assess segment control and movement amplitude. Symptom severity, balance confidence, and medical history were established before participants walked on a treadmill at 70%, 100%, and 130% of their preferred speed. Head and trunk control was lower for PD fallers than PD nonfallers and older adults. Significant interactions indicated head and trunk control increased with speed for PD nonfallers and older adults, but did not improve at faster speeds for PD fallers. Vertical head and trunk accelerations increased with walking speed for PD nonfallers and older adults, while the PD fallers demonstrated greater anteroposterior RMS accelerations compared with both other groups. The results suggest that improved gait dynamics do not necessarily represent improved walking stability, and this must be respected when rehabilitating gait in patients with PD. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Hand grip strength and dexterity function in children aged 6-12 years: A cross-sectional study.
Omar, Mohammed T A; Alghadir, Ahmad H; Zafar, Hamayun; Al Baker, Shaheerah
Cross-sectional and clinical measurement. Assessment of hand function considers an essential part in clinical practice. To develop normative values of hand grip strength and dexterity function for 6-12-year-old children in Saudi Arabia. Grip strength and dexterity function was measured in 525 children using Grip Track hand dynamometer (JTECH Medical, Midvale, UT, USA) and 9-hole pegboard test respectively. The grip strength and dexterity function was improved as age progressed regardless of gender. Across all age groups, the hand grip strength of boys was significantly higher than girls for dominant hand (31.75 ± 10.33 vs 28.24 ± 9.35; P < .001) and nondominant hand (31.01 ± 10.27 vs 27.27 ± 9.30; P < .001). The girls performed slightly faster than boys for dominant hand (19.70 vs 20.68; P < .05) and nondominant hand (21.79 vs 23.46; P < .05). In general, girls completed a 9-HPT faster than boys in the 2 of 7 age groups: 11 years (9-HPT scores = 2.10 seconds; P < .01) and 12 years (9-HPT scores = 1.93 seconds; P < .01). The overall patterns of hand grip strength and dexterity function observed in the present study are similar to the previous studies that established acceleration of grip strength with advanced age, and faster performance scores in older children than younger children in both genders. Norms of hand grip strength and dexterity enable therapists to identify some developmental characteristics of hand function among Saudi children, determine the presence of impairment, and compare scores from children in different clinical settings. Not applicable. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Le Vine, D. M.; Willett, J. C.; Bailey, J. C.
1989-01-01
Fast electric field changes from subsequent return strokes of natural and triggered lightning with propagation paths almost entirely over water are compared. Data were collected at the Kennedy Space Center, Florida, during the summer of 1987. Comparisons have been made of the average shape, the risetime, and the spectrum of the electric field changes. To a first approximation, the waveforms are very similar; however, the electric field changes from the triggered flashes tend to rise to peak faster and decay faster than do their counterparts in natural cloud-to-ground flashes.
Evaluating Zeolite-Modified Sensors: towards a faster set of chemical sensors
NASA Astrophysics Data System (ADS)
Berna, A. Z.; Vergara, A.; Trincavelli, M.; Huerta, R.; Afonja, A.; Parkin, I. P.; Binions, R.; Trowell, S.
2011-09-01
The responses of zeolite-modified sensors, prepared by screen printing layers of chromium titanium oxide (CTO), were compared to unmodified tin oxide sensors using amplitude and transient responses. For transient responses we used a family of features, derived from the exponential moving average (EMA), to characterize chemo-resistive responses. All sensors were tested simultaneously against 20 individual volatile compounds from four chemical groups. The responses of the two types of sensors showed some independence. The zeolite-modified CTO sensors discriminated compounds better using either amplitude response or EMA features and CTO-modified sensors also responded three times faster.
Baldofski, Sabrina; Lüthold, Patrick; Sperling, Ingmar; Hilbert, Anja
2018-03-01
Night eating syndrome (NES) is characterized by excessive evening and/or nocturnal eating episodes. Studies indicate an attentional bias towards food in other eating disorders. For NES, however, evidence of attentional food processing is lacking. Attention towards food and non-food stimuli was compared using eye-tracking in 19 participants with NES and 19 matched controls without eating disorders during a free exploration paradigm and a visual search task. In the free exploration paradigm, groups did not differ in initial fixation position or gaze duration. However, a significant orienting bias to food compared to non-food was found within the NES group, but not in controls. A significant attentional maintenance bias to non-food compared to food was found in both groups. Detection times did not differ between groups in the search task. Only in NES, attention to and faster detection of non-food stimuli were related to higher BMI and more evening eating episodes. The results might indicate an attentional approach-avoidance pattern towards food in NES. However, further studies should clarify the implications of attentional mechanisms for the etiology and maintenance of NES. Copyright © 2017. Published by Elsevier Ltd.
Loupe magnification for small incision cataract surgery--an alternative to microscope magnification?
Singh, S K; Winter, I; Hennig, A
2008-01-01
A Prospective randomized controlled study was conducted to compare outcome of Small Incision Cataract Surgery (SICS) using microscope or loupe magnification. Two hundred fifty one patient with mature cataract were randomly allocated to SICS-Fishhook Technique with either microscope (127 eyes) or loupe (124 eyes) magnification. Intra- and postoperative complications and immediate visual outcome were analyzed. Nearly two third (microscope 65% and magnifying loupe 62.9%) of all patients had good visual outcome on first postoperative day. Poor outcome (<6/60) was recorded in 8% (microscope group) and 7% (magnifying loupe group). Mean visual acuity with Snellen was 0.39 (SD 0.2) in microscope group and 0.38 (SD 0.2) in magnifying loupe group. Intra operative complications were comparable in both groups. Mean surgery time with loupe magnification was significantly shorter. Comparatively equivalent good surgical outcome was achieved with loupe as well as with microscope magnification. However performing SICS with loupe magnification is significantly faster. Small incision cataract surgery with loupe magnification is safe and effective procedure for cataract surgery so it can play a role in reducing cataract blindness in developing countries of the world.
Fast retinal layer segmentation of spectral domain optical coherence tomography images
NASA Astrophysics Data System (ADS)
Zhang, Tianqiao; Song, Zhangjun; Wang, Xiaogang; Zheng, Huimin; Jia, Fucang; Wu, Jianhuang; Li, Guanglin; Hu, Qingmao
2015-09-01
An approach to segment macular layer thicknesses from spectral domain optical coherence tomography has been proposed. The main contribution is to decrease computational costs while maintaining high accuracy via exploring Kalman filtering, customized active contour, and curve smoothing. Validation on 21 normal volumes shows that 8 layer boundaries could be segmented within 5.8 s with an average layer boundary error <2.35 μm. It has been compared with state-of-the-art methods for both normal and age-related macular degeneration cases to yield similar or significantly better accuracy and is 37 times faster. The proposed method could be a potential tool to clinically quantify the retinal layer boundaries.
Evidence for size-selective mortality after the first summer of ocean growth by pink salmon
Moss, J.H.; Beauchamp, D.A.; Cross, A.D.; Myers, K.W.; Farley, Edward V.; Murphy, J.M.; Helle, J.H.
2005-01-01
Pink salmon Onchorhynchus gorbuscha with identifiable thermal otolith marks from Prince William Sound hatchery release groups during 2001 were used to test the hypothesis that faster-growing fish during their first summer in the ocean had higher survival rates than slower-growing fish. Marked juvenile pink salmon were sampled monthly in Prince William Sound and the Gulf of Alaska, and adults that survived to maturity were recovered at hatchery release sites the following year. Surviving fish exhibited significantly wider circuli spacing on the region of the scale formed during early marine residence than did juveniles collected at sea during their first ocean summer, indicating that marine survival after the first growing season was related to increases in early marine growth. At the same circuli, a significantly larger average scale radius for returning adults than for juveniles from the same hatchery would suggest that larger, faster-growing juveniles had a higher survival rate and that significant size-selective mortality occurred after the juveniles were sampled. Growth patterns inferred from intercirculi spacing on scales varied among hatchery release groups, suggesting that density-dependent processes differed among release groups and occurred across Prince William Sound and the coastal Gulf of Alaska. These observations support other studies that have found that larger, faster-growing fish are more likely to survive until maturity. ?? Copyright by the American Fisheries Society 2005.
Ozcan, Ayse; Tulum, Zeliha; Pinar, Lamia; Başkurt, Ferdi
2004-12-01
This study was done to evaluate differences in pressure pain threshold, grip strength, manual dexterity and touch pressure threshold in the dominant and non-dominant hands of right- and left-handed subjects, and to compare findings within and between these groups. Thirty-nine right-handed and twenty-one left-handed subjects participated in the study. Pressure pain threshold was assessed using a dolorimeter, grip strength was assessed with a hand-grip dynamometer, manual dexterity was evaluated using the VALPAR Component Work Sample-4 system, and touch pressure threshold was determined using Semmes Weinstein monofilaments. Results for the dominant and non-dominant hands were compared within and between the groups. In the right-handed subjects, the dominant hand was significantly faster with the VALPAR Component Work Sample-4, showed significantly greater grip strength, and had a significantly higher pressure pain threshold than the non-dominant hand. The corresponding results for the two hands were similar in the left-handed subjects. The study revealed asymmetrical manual performance in grip strength, manual dexterity and pressure pain threshold in right-handed subjects, but no such asymmetries in left-handed subjects.
Westbrook, J I; Georgiou, A; Dimos, A; Germanos, T
2006-01-01
Objective To assess the impact of a computerised pathology order entry system on laboratory turnaround times and test ordering within a teaching hospital. Methods A controlled before and after study compared test assays ordered from 11 wards two months before (n = 97 851) and after (n = 113 762) the implementation of a computerised pathology order entry system (Cerner Millennium Powerchart). Comparisons were made of laboratory turnaround times, frequency of tests ordered and specimens taken, proportions of patients having tests, average number per patient, and percentage of gentamicin and vancomycin specimens labelled as random. Results Intervention wards experienced an average decrease in turnaround of 15.5 minutes/test assay (range 73.8 to 58.3 minutes; p<0.001). Reductions were significant for prioritised and non‐prioritised tests, and for those done within and outside business hours. There was no significant change in the average number of tests (p = 0.228), or specimens per patient (p = 0.324), and no change in turnaround time for the control ward (p = 0.218). Use of structured order screens enhanced data provided to laboratories. Removing three test assays from the liver function order set resulted in significantly fewer of these tests being done. Conclusions Computerised order entry systems are an important element in achieving faster test results. These systems can influence test ordering patterns through structured order screens, manipulation of order sets, and analysis of real time data to assess the impact of such changes, not possible with paper based systems. The extent to which improvements translate into improved patient outcomes remains to be determined. A potentially limiting factor is clinicians' capacity to respond to, and make use of, faster test results. PMID:16461564
Kavros, Steven J
2012-08-01
Gross deformity of the foot in Charcot neuroarthropathy can lead to collapse and subsequent ulceration, infection, amputation, or premature death. This study evaluated healing of midfoot ulcerations of Charcot neuroarthropathy using PriMatrix, a novel acellular fetal bovine dermal matrix. In this retrospective analysis, 20 patients with ulcerations of the midfoot associated with Charcot neuroarthropathy were treated with either PriMatrix in addition to standard wound care (PriMatrix group,n = 12) or standard wound care alone (control group, n = 8). All patients had chronic, nonhealing foot ulcerations of at least 2250 mm(3) for a minimum of 30 days duration. All foot ulcerations were full thickness with subcutaneous involvement. Ankle brachial index ≥0.90 and/or transcutaneous oximetry (TcPo(2)) ≥40 mm Hg at the periulcer site was necessary for inclusion. Patients were excluded if they had acute or chronic osteomyelitis of the foot. Demography, risk factors, baseline severity of Charcot neuroarthropathy, and wound volume (control 4078 mm(3), PriMatrix 3737.5 mm(3), P = nonsignificant) were similar between treatment groups. Mean time to healing in the PriMatrix group (116 days, 95% CI = 109-123) was significantly shorter than in the control group (180 days, 95% confidence interval [CI] = 171-188); P < .0001. A significantly faster rate of healing was observed with PriMatrix (87.9 mm(3)/wk, 95% CI = 115.2% to 60.6%) compared with control (59.0 mm(3)/wk, 95% CI = 72.8% to 45.3%); P < .0001). The significantly faster rate of healing and steeper slope of volume reduction in the PriMatrix group warrants further investigation into its effects on healing of neuropathic ulcerations and potential limb salvage.
Dalgaard, Vita Ligaya; Aschbacher, Kirstin; Andersen, Johan Hviid; Glasscock, David John; Willert, Morten Vejs; Carstensen, Ole; Biering, Karin
2017-09-01
Objectives This study aimed to evaluate the effect of a stress management intervention (SMI) on lasting return to work (RTW) among patients with work-related stress complaints. Methods Sickness benefit departments from three local municipalities referred patients on sick leave with work-related adjustment disorders or mild depression to the Department of Occupational Medicine, Regional Hospital West Jutland. A 2× randomization procedure allocated patients into one of three groups: intervention (N=58), control A (which received a clinical assessment; N=56), or control B (no assessment; N=49). Treatment comprised individual work-focused cognitive behavioral therapy (CBT) with an optional workplace intervention. The outcome was time until lasting RTW (16 and 44 weeks follow-up) using register data. Results Median number of weeks until lasting RTW was 15, 19, and 32 for the intervention group, control A, and control B respectively. However, for group B, clinical assessment was not part of the inclusion process, which may have introduced selection bias. In the fully-adjusted Cox regression model, the intervention group exhibited significantly faster lasting RTW at 44 weeks; hazard ratio (HR) 1.57 [95% confidence interval (95% CI) 1.01-2.44] relative to control group A, with a non-significant trend evident at 16 weeks; HR 1.70 (95% CI 0.94-3.10), when controlling for age, gender, occupation, sick leave during previous year, full or partial sick leave, and diagnosis. Unadjusted analyses remained directionally consistent but were reduced to marginal significance. Conclusions There was a tendency towards faster lasting RTW in the intervention group compared to control A, which received clinical assessment, in all analyses. The intervention group returned to work about 4 weeks earlier than control A, which could translate into substantial financial gains.
Malinova, Vesna; Schlegel, Anna; Rohde, Veit; Mielke, Dorothee
2017-07-01
For the fibrinolytic therapy of intracerebral hematomas (ICH) using recombinant tissue plasminogen activator (rtPA), a catheter position in the core of the hematoma along the largest clot diameter was assumed to be optimal for an effective clot lysis. However, it never had been proven that core position indeed enhances clot lysis if compared with less optimal catheter positions. In this study, the impact of the catheter position on the effectiveness and on the time course of clot lysis was evaluated. We analyzed the catheter position using a relative error calculating the distance perpendicular to the catheter's center in relation to hematoma's diameter and evaluated the relative hematoma volume reduction (RVR). The correlation of the RVR with the catheter position was evaluated. Additionally, we tried to identify patterns of clot lysis with different catheter positions. The patient's outcome at discharge was evaluated using the Glasgow outcome score. A total of 105 patients were included in the study. The mean hematoma volume was 56 ml. The overall RVR was 62.7 %. In 69 patients, a catheter position in the core of the clot was achieved. We found no significant correlation between catheter position and hematoma RVR (linear regression, p = 0.14). Core catheter position leads to more symmetrical hematoma RVR. Faster clot lysis happens in the vicinity of the catheter openings. We found no significant difference in the patient's outcome dependent on the catheter position (linear regression, p = 0.90). The catheter position in the core of the hematoma along its largest diameter does not significantly influence the effectiveness of clot lysis after rtPA application.
Granone, Tiffany D; de Francisco, Olga N; Killos, Maria B; Quandt, Jane E; Mandsager, Ron E; Graham, Lynelle F
2012-01-01
To compare isoflurane, sevoflurane and desflurane for inhalant anesthesia in red-tailed hawks (Buteo jamaicensis) in terms of the speed and characteristics of induction; cardiovascular and respiratory parameters while anesthetized; and speed and quality of recovery. Prospective, cross over, randomized experimental study. 12 healthy adult red-tailed hawks. Anesthesia was induced with isoflurane, sevoflurane or desflurane in oxygen via face mask in a crossover, randomized design with a 1 week washout period between each treatment. Hawks were tracheally intubated, allowed to breathe spontaneously, and instrumented for cardiopulmonary monitoring. Data collected included heart rate, respiratory rate, end-tidal CO(2) , inspired and expired agent, SpO(2,) temperature, systolic blood pressure, time to intubation and time to recovery (tracking). Recovery was subjectively scored on a 4 point scale as well as a summary evaluation, by a single blinded observer. No significant difference in time to induction and time to extubation was noted with the administration of isoflurane, sevoflurane or desflurane. Time to the ability of the bird to follow a moving object with its eyes (tracking) was significantly faster with the administration of sevoflurane and desflurane. All recoveries were scored 1 or 2 and were assessed as good to excellent. No significant difference was noted in heart rate, blood pressure and temperature among the three inhalants. Administration of isoflurane resulted in lower respiratory rates. Overall, although isoflurane remains the most common inhaled anesthetic in avian practice, sevoflurane and desflurane both offer faster time to tracking, while similar changes in cardiopulmonary function were observed with each agent during anesthesia of healthy red-tailed hawks. © 2011 The Authors. Veterinary Anaesthesia and Analgesia. © 2011 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.
Carrera, Adrián; Pifarré, Marc; Vilaplana, Jordi; Cuadrado, Josep; Solsona, Sara; Mateo, Jordi
2016-01-01
Summary Background Hypertension or high blood pressure is on the rise. Not only does it affect the elderly but is also increasingly spreading to younger sectors of the population. Treating this condition involves exhaustive monitoring of patients. The current mobile health services can be improved to perform this task more effectively. Objective To develop a useful, user-friendly, robust and efficient app, to monitor hypertensive patients and adapted to the particular requirements of hypertension. Methods This work presents BPcontrol, an Android and iOS app that allows hypertensive patients to communicate with their health-care centers, thus facilitating monitoring and diagnosis. Usability, robustness and efficiency factors for BPcontrol were evaluated for different devices and operating systems (Android, iOS and system-aware). Furthermore, its features were compared with other similar apps in the literature. Results BPcontrol is robust and user-friendly. The respective start-up efficiency of the Android and iOS versions of BPcontrol were 2.4 and 8.8 times faster than a system-aware app. Similar values were obtained for the communication efficiency (7.25 and 11.75 times faster for the Android and iOS respectively). When comparing plotting performance, BPcontrol was on average 2.25 times faster in the Android case. Most of the apps in the literature have no communication with a server, thus making it impossible to compare their performance with BPcontrol. Conclusions Its optimal design and the good behavior of its facilities make BPcontrol a very promising mobile app for monitoring hypertensive patients. PMID:27924346
BPcontrol. A Mobile App to Monitor Hypertensive Patients.
Carrera, Adrian; Pifarré, Marc; Vilaplana, Jordi; Cuadrado, Josep; Solsona, Sara; Mateo, Jordi; Solsona, Francesc
2016-12-07
Hypertension or high blood pressure is on the rise. Not only does it affect the elderly but is also increasingly spreading to younger sectors of the population. Treating this condition involves exhaustive monitoring of patients. The current mobile health services can be improved to perform this task more effectively. To develop a useful, user-friendly, robust and efficient app, to monitor hypertensive patients and adapted to the particular requirements of hypertension. This work presents BPcontrol, an Android and iOS app that allows hypertensive patients to communicate with their health-care centers, thus facilitating monitoring and diagnosis. Usability, robustness and efficiency factors for BPcontrol were evaluated for different devices and operating systems (Android, iOS and system-aware). Furthermore, its features were compared with other similar apps in the literature. BPcontrol is robust and user-friendly. The respective start-up efficiency of the Android and iOS versions of BPcontrol were 2.4 and 8.8 times faster than a system-aware app. Similar values were obtained for the communication efficiency (7.25 and 11.75 times faster for the Android and iOS respectively). When comparing plotting performance, BPcontrol was on average 2.25 times faster in the Android case. Most of the apps in the literature have no communication with a server, thus making it impossible to compare their performance with BPcontrol. Its optimal design and the good behavior of its facilities make BPcontrol a very promising mobile app for monitoring hypertensive patients.
Nainggolan, Leonard; Bardosono, Saptawati; Ibrahim Ilyas, Ermita I
2018-01-01
Plasma leakage plays an important role in dengue infection, and this condition can lead to hemoconcentration, hypovolemia, and shock. Fluid replacement is the main treatment for dengue. There is a lack of evidence to support certain oral fluid therapy as a treatment for dengue patients. The objective of this study is to evaluate tolerability and efficacy of oral isotonic solution (OIS) compared to plain water as a fluid replacement in dengue patients. A randomized, clinical trial with single-blinded groups was conducted to compare tolerability and efficacy of OIS and plain water in dengue patients. We evaluated gastrointestinal disturbances (nausea, vomiting, and bloating), body temperature, mean arterial pressure (MAP), fluid balance, hematocrit, Na + , and K + levels. Data were analyzed with SPSS 20.0, and figures were made with GraphPad Prism version 5.01. Twenty four subjects were included and divided equally into two groups. Our results showed that there are no significant differences but indicate several noteworthy trends. The intervention group (OIS) experienced less nausea, less vomiting, had positive fluid balance and higher MAP, and became afebrile faster compared to the control group (plain water). Although not statistically significant, this study shows the trend that OIS is well-tolerated and effective for dengue patients compared to plain water.
Goal-driven modulation of stimulus-driven attentional capture in multiple-cue displays.
Richard, Christian M; Wright, Richard D; Ward, Lawrence M
2003-08-01
Six location-cuing experiments were conducted to examine the goal-driven control of attentional capture in multiple-cue displays. In most of the experiments, the cue display consisted of the simultaneous presentation of a red direct cue that was highly predictive of the target location (the unique cue) and three gray direct cues (the standard cues) that were not predictive of the location. The results indicated that although target responses were faster at all cued locations relative to uncued locations, they were significantly faster at the unique-cue location than at the standard-cue locations. Other results suggest that the faster responses produced by direct cues may be associated with two different components: an attention-related component that can be modulated by goal-driven factors and a nonattentional component that occurs in parallel at multiple direct-cue locations and is minimally affected by the same goal-driven factors.
Rapiejko, Piotr; Jurkiewicz, Dariusz
2010-01-01
Surgical operations on the nose are very common otorhinolaryngological procedures. The surgical outcome depends not only on the performance of the procedure itself but also on the postoperative care of the nasal cavities. Clinicians continue their search for agents which would promote cleansing of the nasal cavities and regeneration of the nasal mucosa postoperatively. was a retrospective evaluation of the effect of the product Marimer Hypertonic on symptoms in patients who had undergone nasal surgery (septoplasty, functional endoscopic sinus surgery, surgical removal of nasal polyps). The medical records included details of full history and physical examination on postoperative days 1, 7 and 14.The medical records of 120 patients were randomly selected from all records. The records were consecutively selected using the following criteria: 1-Operation type; septoplasty group A and B, FESS group C and D or classical surgical removal of nasal polyps group E and F , 2- Use (group B, D, F) or non-use (group A, C, E) of the hypertonic sea water solution aerosol for nasal douching (Marimer Hypertonic 2.2% sea-water solution). All patients included in the postoperative follow-up at the ENT Outpatient Clinic assess their symptoms by completing a standard self-assessment chart. The symptoms include nasal obstruction, discharge and crusting in the nasal cavities, pain in the nose and paranasal sinuses, reduction of smell, and general health (disease severity) and are assessed on day 1 after removal of nasal packing and on treatment days 7 and 14. At the same time, a clinician assesses their condition, including general health, nasal blockage, discharge and crusting in the nasal cavities, appearance of the nasal mucosa, and sense of smell evaluated by a scratch test using a smell book and a felt-tip pen test. A statistically significance difference in the severity of disease between group A (control) and group B (using Marimer Hypertonic) indicates a statistically significant beneficial effect of nasal douching with Marimer Hypertonic after septoplasty. As early as day 7 after surgery, the disease severity rated by the participants was reduced by 58% in patients usining Marimer Hypertonic compared to 25% in controls. On day 14, the reduction was by 84% and by 51% respectively. The use of Marimer Hypertonic after septoplasty produced a much faster relief of nasal obstruction/blockage as assessed by both patients and clinicians. In the opinion of patients using Mariner Hypertonic, on day 7 and day 14 nasal obstruction/blockage was reduced by 73% and by 87% respectively while in controls the corresponding values were 14% and 48%. Nasal douching with Marimer Hypertonic produced faster relief of discomfort caused by the accumulation of abnormal nasal discharge and crusting. In the assessment of patients from the control group, 14 days after surgery abnormal nasal discharge and crusting persisted at a level similar to that reported immediately after septoplasty. In the group using Marimer Hypertonic, the symptoms reported by patients subsided by 58% and 88% by day 7 and day 14 respectively. As assessed by clinicians using rhinoscopy and endoscopy, the improvement of nasal discharge and crusting was significantly faster and more effective in patients using Marimer Hypertonic (by 70% on day 7 and 95% on day 14) compared to controls (15% and 45% respectively). The use of Marimer Hypertonic after FESS produced a much faster relief of nasal obstruction/blockage as assessed by both patients and clinicians. In the opinion of patients using Mariner Hypertonic, on day 7 and day 14 nasal obstruction/blockage was reduced by 73% and by 87% respectively while in controls the corresponding values were 23% and 61%. Nasal douching with Marimer Hypertonic was found to produce an obvious statistically significant beneficial effect resulting in the relief of discomfort caused by crusting and accumulation of abnormal nasal discharge after FESS. By day 7 the symptoms reported by patients subsided by 78% in patients using Marimer Hypertonic and by 88% in controls. By day 14 the symptoms decreased by 93% and 47 % respectively. As assessed by clinicians using rhinoscopy and endoscopy, the improvement of nasal discharge and crusting was significantly faster and more effective in patients using Marimer Hypertonic (by 84% on day 7 and 95% on day 14) compared to controls (11% and 26% respectively). The use of Marimer Hypertonic after polypectomy produced a much faster relief of nasal obstruction/blockage as assessed by both patients and clinicians. On day 7 nasal obstruction/blockage was reduced by 73% in patients using Marimer Hypertonic and by 14% in controls. On day 14 the corresponding values were 89% and 50%. The findings of the present study support the investigators' opinion that the use of hypertonic sea-water solution, i.e. the product Marimer Hypertonic should be recommended for nasal douching after corrective nasal septal surgery (septoplasty), functional endoscopic sinus surgery (FESS) and surgical removal of nasal polyps (polypectomy). The use of Marimer Hypertonic facilitates maintenance of normal patency of the nasal cavities, reduces the amount of abnormal nasal discharge and crusting and speeds up healing of iatrogenic injuries of the mucous membrane of the nose.
Rejman, Marek; Wiesner, Wojciech; Silakiewicz, Piotr; Klarowicz, Andrzej; Abraldes, J. Arturo
2012-01-01
The aim of this study was an analysis of the time required to swim to a victim and tow them back to shore, while perfoming the flutter-kick and the dolphin-kick using fins. It has been hypothesized that using fins while using the dolphin-kick when swimming leads to reduced rescue time. Sixteen lifeguards took part in the study. The main tasks performed by them, were to approach and tow (double armpit) a dummy a distance of 50m while applying either the flutter-kick, or the dolphin-kick with fins. The analysis of the temporal parameters of both techniques of kicking demonstrates that, during the approach to the victim, neither the dolphin (tmean = 32.9s) or the flutter kick (tmean = 33.0s) were significantly faster than the other. However, when used for towing a victim the flutter kick (tmean = 47.1s) was significantly faster when compared to the dolphin-kick (tmean = 52.8s). An assessment of the level of technical skills in competitive swimming, and in approaching and towing the victim, were also conducted. Towing time was significantly correlated with the parameter that linked the temporal and technical dimensions of towing and swimming (difference between flutter kick towing time and dolphin-kick towing time, 100m medley time and the four swimming strokes evaluation). No similar interdependency has been discovered in flutter kick towing time. These findings suggest that the dolphin-kick is a more difficult skill to perform when towing the victim than the flutter-kick. Since the hypothesis stated was not confirmed, postulates were formulated on how to improve dolphin-kick technique with fins, in order to reduce swimming rescue time. Key points The source of reduction of swimming rescue time was researched. Time required to approach and to tow the victim while doing the flutter kick and the dolphin-kick with fins was analyzed. The propulsion generated by dolphin-kick did not make the approach and tow faster than the flutter kick. More difficult skill to realize of dolphin-kick than the flutter-kick was postulated. The criteria for how improve dolphin kick technique with fins were formulated. PMID:24150079
Effect of oral mesalamine on inflammatory response in acute uncomplicated diverticulitis
Nespoli, Luca; Lo Bianco, Giulia; Uggeri, Fabio; Romano, Fabrizio; Nespoli, Angelo; Bernasconi, Davide Paolo; Gianotti, Luca
2015-01-01
AIM: To evaluate the impact of mesalamine administration on inflammatory response in acute uncomplicated diverticulitis. METHODS: We conducted a single centre retrospective cohort study on patients admitted to our surgical department between January 2012 and May 2014 with a computed tomography -confirmed diagnosis of acute uncomplicated diverticulitis. A total of 50 patients were included in the analysis, 20 (study group) had received 3.2 g/d of mesalamine starting from the day of admission in addition to the usual standard treatment, 30 (control group) had received standard therapy alone. Data was retrieved from a prospective database. Our primary study endpoints were: C reactive protein mean levels over time and their variation from baseline (ΔCRP) over the first three days of treatment. Secondary end points included: mean white blood cell and neutrophile count over time, time before regaining of regular bowel movements (passing of stools), time before reintroduction of food intake, intensity of lower abdominal pain over time, analgesic consumption and length of hospital stay. RESULTS: Patients characteristics and inflammatory parameters were similar at baseline in the two groups. The evaluation of CRP levels over time showed, in treated patients, a distinct trend towards a faster decrease compared to controls. This difference approached statistical significance on day 2 (mean CRP 6.0 +/- 4.2 mg/dL and 10.0 +/- 6.7 mg/dL respectively in study group vs controls, P = 0.055). ΔCRP evaluation evidenced a significantly greater increment of this inflammatory marker in the control group on day 1 (P = 0.03). A similar trend towards a faster resolution of inflammation was observed evaluating the total white blood cell count. Neutrophile levels were significantly lower in treated patients on day 2 and on day 3 (P < 0.05 for both comparisons). Mesalamine administration was also associated with an earlier reintroduction of food intake (median 1.5 d and 3 d, study group vs controls respectively, P < 0.001) and with a shorter hospital stay (median 5 d and 5.5 d, study group vs controls respectively, P = 0.03). CONCLUSION: Despite its limitations, this study suggests that mesalamine may allow for a faster recovery and for a reduction of inflammatory response in acute uncomplicated diverticulitis. PMID:26217088
Effect of oral mesalamine on inflammatory response in acute uncomplicated diverticulitis.
Nespoli, Luca; Lo Bianco, Giulia; Uggeri, Fabio; Romano, Fabrizio; Nespoli, Angelo; Bernasconi, Davide Paolo; Gianotti, Luca
2015-07-21
To evaluate the impact of mesalamine administration on inflammatory response in acute uncomplicated diverticulitis. We conducted a single centre retrospective cohort study on patients admitted to our surgical department between January 2012 and May 2014 with a computed tomography -confirmed diagnosis of acute uncomplicated diverticulitis. A total of 50 patients were included in the analysis, 20 (study group) had received 3.2 g/d of mesalamine starting from the day of admission in addition to the usual standard treatment, 30 (control group) had received standard therapy alone. Data was retrieved from a prospective database. Our primary study endpoints were: C reactive protein mean levels over time and their variation from baseline (ΔCRP) over the first three days of treatment. Secondary end points included: mean white blood cell and neutrophile count over time, time before regaining of regular bowel movements (passing of stools), time before reintroduction of food intake, intensity of lower abdominal pain over time, analgesic consumption and length of hospital stay. Patients characteristics and inflammatory parameters were similar at baseline in the two groups. The evaluation of CRP levels over time showed, in treated patients, a distinct trend towards a faster decrease compared to controls. This difference approached statistical significance on day 2 (mean CRP 6.0 +/- 4.2 mg/dL and 10.0 +/- 6.7 mg/dL respectively in study group vs controls, P = 0.055). ΔCRP evaluation evidenced a significantly greater increment of this inflammatory marker in the control group on day 1 (P = 0.03). A similar trend towards a faster resolution of inflammation was observed evaluating the total white blood cell count. Neutrophile levels were significantly lower in treated patients on day 2 and on day 3 (P < 0.05 for both comparisons). Mesalamine administration was also associated with an earlier reintroduction of food intake (median 1.5 d and 3 d, study group vs controls respectively, P < 0.001) and with a shorter hospital stay (median 5 d and 5.5 d, study group vs controls respectively, P = 0.03). Despite its limitations, this study suggests that mesalamine may allow for a faster recovery and for a reduction of inflammatory response in acute uncomplicated diverticulitis.
Thinking about touch facilitates tactile but not auditory processing.
Anema, Helen A; de Haan, Alyanne M; Gebuis, Titia; Dijkerman, H Chris
2012-05-01
Mental imagery is considered to be important for normal conscious experience. It is most frequently investigated in the visual, auditory and motor domain (imagination of movement), while the studies on tactile imagery (imagination of touch) are scarce. The current study investigated the effect of tactile and auditory imagery on the left/right discriminations of tactile and auditory stimuli. In line with our hypothesis, we observed that after tactile imagery, tactile stimuli were responded to faster as compared to auditory stimuli and vice versa. On average, tactile stimuli were responded to faster as compared to auditory stimuli, and stimuli in the imagery condition were on average responded to slower as compared to baseline performance (left/right discrimination without imagery assignment). The former is probably due to the spatial and somatotopic proximity of the fingers receiving the taps and the thumbs performing the response (button press), the latter to a dual task cost. Together, these results provide the first evidence of a behavioural effect of a tactile imagery assignment on the perception of real tactile stimuli.
The cost-effectiveness of TheraBite® as treatment for acute myogenic temporomandibular disorder.
Heres Diddens, Andreas; Kraaijenga, Sophie; Coupé, Veerle; Hilgers, Frans; van der Molen, Lisette; Smeele, Ludi; Retèl, Valesca
2017-09-01
Temporomandibular disorder (TMD) is a very common and costly pain problem concerning the temporomandibular joint. A previous study has shown that for the treatment of acute myogenic TMD, TheraBite® (TB) offers a faster and greater effect than usual care consisting of physical therapy (PT). This study estimates the cost-effectiveness of TB compared to PT. Differences in costs and quality-adjusted life-years (QALYs) between TB and PT are analyzed using a decision model. The point estimate for the incremental cost-effectiveness ratio is -28,068 EUR (-30,191 USD) per QALY (dominant) for TB versus PT. At the willingness-to-pay ratio of 20,000 EUR (21,513 USD) per QALY, TB has a 97% probability of being cost-effective compared to PT. TB is expected to be cost-effective compared to PT for the treatment of acute myogenic TMD, offering faster recovery of quality of life for patients, at a lower cost to society.
Bayineni, Venkata Krishna; Venkatesh, Krishna; Sahu, Chandan Kumar; Kadeppagari, Ravi-Kumar
2016-04-01
Methotrexate degrading enzymes are required to overcome the toxicity of the methotrexate while treating the cancer. The enzyme from Variovorax paradoxus converts the methotrexate in to non toxic products. Methotrexate degrading enzyme from V. paradoxus is a dimeric protein with a molecular mass of 46 kDa and it acts on casein and gelatin. This enzyme is optimally active at pH 7.5 and 40°C and nanoparticles of this enzyme were prepared by desolvation-crosslinking method. Enzyme nanoparticles could degrade methotrexate faster than the native enzyme and they show lower Km compare to the native enzyme. Enzyme nanoparticles show better thermostability and they were stable for much longer time in the serum compare to the native enzyme. Enzyme nanoparticles show better functionality than the native enzyme while clearing the methotrexate added to the serum suggesting their advantage over the native enzyme for the therapeutic and biotechnological applications. Copyright © 2016 Elsevier Inc. All rights reserved.
The Size Congruity Effect: Is Bigger Always More?
ERIC Educational Resources Information Center
Santens, Seppe; Verguts, Tom
2011-01-01
When comparing digits of different physical sizes, numerical and physical size interact. For example, in a numerical comparison task, people are faster to compare two digits when their numerical size (the relevant dimension) and physical size (the irrelevant dimension) are congruent than when they are incongruent. Two main accounts have been put…
The impact of video games on training surgeons in the 21st century.
Rosser, James C; Lynch, Paul J; Cuddihy, Laurie; Gentile, Douglas A; Klonsky, Jonathan; Merrell, Ronald
2007-02-01
Video games have become extensively integrated into popular culture. Anecdotal observations of young surgeons suggest that video game play contributes to performance excellence in laparoscopic surgery. Training benefits for surgeons who play video games should be quantifiable. There is a potential link between video game play and laparoscopic surgical skill and suturing. Cross-sectional analysis of the performance of surgical residents and attending physicians participating in the Rosser Top Gun Laparoscopic Skills and Suturing Program (Top Gun). Three different video game exercises were performed, and surveys were completed to assess past experience with video games and current level of play, and each subject's level of surgical training, number of laparoscopic cases performed, and number of years in medical practice. Academic medical center and surgical training program. Thirty-three residents and attending physicians participating in Top Gun from May 10 to August 24, 2002. The primary outcome measures were compared between participants' laparoscopic skills and suturing capability, video game scores, and video game experience. Past video game play in excess of 3 h/wk correlated with 37% fewer errors (P<.02) and 27% faster completion (P<.03). Overall Top Gun score (time and errors) was 33% better (P<.005) for video game players and 42% better (P<.01) if they played more than 3 h/wk. Current video game players made 32% fewer errors (P=.04), performed 24% faster (P<.04), and scored 26% better overall (time and errors) (P<.005) than their nonplaying colleagues. When comparing demonstrated video gaming skills, those in the top tertile made 47% fewer errors, performed 39% faster, and scored 41% better (P<.001 for all) on the overall Top Gun score. Regression analysis also indicated that video game skill and past video game experience are significant predictors of demonstrated laparoscopic skills. Video game skill correlates with laparoscopic surgical skills. Training curricula that include video games may help thin the technical interface between surgeons and screen-mediated applications, such as laparoscopic surgery. Video games may be a practical teaching tool to help train surgeons.
The Impact of Accelerating Faster than Exponential Population Growth on Genetic Variation
Reppell, Mark; Boehnke, Michael; Zöllner, Sebastian
2014-01-01
Current human sequencing projects observe an abundance of extremely rare genetic variation, suggesting recent acceleration of population growth. To better understand the impact of such accelerating growth on the quantity and nature of genetic variation, we present a new class of models capable of incorporating faster than exponential growth in a coalescent framework. Our work shows that such accelerated growth affects only the population size in the recent past and thus large samples are required to detect the models’ effects on patterns of variation. When we compare models with fixed initial growth rate, models with accelerating growth achieve very large current population sizes and large samples from these populations contain more variation than samples from populations with constant growth. This increase is driven almost entirely by an increase in singleton variation. Moreover, linkage disequilibrium decays faster in populations with accelerating growth. When we instead condition on current population size, models with accelerating growth result in less overall variation and slower linkage disequilibrium decay compared to models with exponential growth. We also find that pairwise linkage disequilibrium of very rare variants contains information about growth rates in the recent past. Finally, we demonstrate that models of accelerating growth may substantially change estimates of present-day effective population sizes and growth times. PMID:24381333
The impact of accelerating faster than exponential population growth on genetic variation.
Reppell, Mark; Boehnke, Michael; Zöllner, Sebastian
2014-03-01
Current human sequencing projects observe an abundance of extremely rare genetic variation, suggesting recent acceleration of population growth. To better understand the impact of such accelerating growth on the quantity and nature of genetic variation, we present a new class of models capable of incorporating faster than exponential growth in a coalescent framework. Our work shows that such accelerated growth affects only the population size in the recent past and thus large samples are required to detect the models' effects on patterns of variation. When we compare models with fixed initial growth rate, models with accelerating growth achieve very large current population sizes and large samples from these populations contain more variation than samples from populations with constant growth. This increase is driven almost entirely by an increase in singleton variation. Moreover, linkage disequilibrium decays faster in populations with accelerating growth. When we instead condition on current population size, models with accelerating growth result in less overall variation and slower linkage disequilibrium decay compared to models with exponential growth. We also find that pairwise linkage disequilibrium of very rare variants contains information about growth rates in the recent past. Finally, we demonstrate that models of accelerating growth may substantially change estimates of present-day effective population sizes and growth times.
Fluorescence Microscopy Gets Faster and Clearer: Roles of Photochemistry and Selective Illumination
Wolenski, Joseph S.; Julich, Doerthe
2014-01-01
Significant advances in fluorescence microscopy tend be a balance between two competing qualities wherein improvements in resolution and low light detection are typically accompanied by losses in acquisition rate and signal-to-noise, respectively. These trade-offs are becoming less of a barrier to biomedical research as recent advances in optoelectronic microscopy and developments in fluorophore chemistry have enabled scientists to see beyond the diffraction barrier, image deeper into live specimens, and acquire images at unprecedented speed. Selective plane illumination microscopy has provided significant gains in the spatial and temporal acquisition of fluorescence specimens several mm in thickness. With commercial systems now available, this method promises to expand on recent advances in 2-photon deep-tissue imaging with improved speed and reduced photobleaching compared to laser scanning confocal microscopy. Superresolution microscopes are also available in several modalities and can be coupled with selective plane illumination techniques. The combination of methods to increase resolution, acquisition speed, and depth of collection are now being married to common microscope systems, enabling scientists to make significant advances in live cell and in situ imaging in real time. We show that light sheet microscopy provides significant advantages for imaging live zebrafish embryos compared to laser scanning confocal microscopy. PMID:24600334
Multisensory integration across the senses in young and old adults
Mahoney, Jeannette R.; Li, Po Ching Clara; Oh-Park, Mooyeon; Verghese, Joe; Holtzer, Roee
2011-01-01
Stimuli are processed concurrently and across multiple sensory inputs. Here we directly compared the effect of multisensory integration (MSI) on reaction time across three paired sensory inputs in eighteen young (M=19.17 yrs) and eighteen old (M=76.44 yrs) individuals. Participants were determined to be non-demented and without any medical or psychiatric conditions that would affect their performance. Participants responded to randomly presented unisensory (auditory, visual, somatosensory) stimuli and three paired sensory inputs consisting of auditory-somatosensory (AS) auditory-visual (AV) and visual-somatosensory (VS) stimuli. Results revealed that reaction time (RT) to all multisensory pairings was significantly faster than those elicited to the constituent unisensory conditions across age groups; findings that could not be accounted for by simple probability summation. Both young and old participants responded the fastest to multisensory pairings containing somatosensory input. Compared to younger adults, older adults demonstrated a significantly greater RT benefit when processing concurrent VS information. In terms of co-activation, older adults demonstrated a significant increase in the magnitude of visual-somatosensory co-activation (i.e., multisensory integration), while younger adults demonstrated a significant increase in the magnitude of auditory-visual and auditory-somatosensory co-activation. This study provides first evidence in support of the facilitative effect of pairing somatosensory with visual stimuli in older adults. PMID:22024545
Up-down Asymmetries in Speed Perception
NASA Technical Reports Server (NTRS)
Thompson, Peter; Stone, Leland S.
1997-01-01
We compared speed matches for pairs of stimuli that moved in opposite directions (upward and downward). Stimuli were elliptical patches (2 deg horizontally by 1 deg vertically) of horizontal sinusoidal gratings of spatial. frequency 2 cycles/deg. Two sequential 380 msec reveal presentations were compared. One of each pair of gratings (the standard) moved at 4 Hz (2 deg/sec), the other (the test) moved at a rate determined by a simple up-down staircase. The point of subjectively equal speed was calculated from the average of the last eight reversals. The task was to fixate a central point and to determine which one of the pair appeared to move faster. Eight of 10 observers perceived the upward drifting grating as moving faster than a grating moving downward but otherwise identical. on average (N = 10), when the standard moved downward, it was matched by a test moving upward at 94.7+/-1.7(SE)% of the standard speed, and when the standard moved upward it was matched by a test moving downward at 105.1+/-2.3(SE)% of the standard speed. Extending this paradigm over a range of spatial (1.5 to 13.5 c/d) and temporal (1.5 to 13.5 Hz) frequencies, preliminary results (N = 4) suggest that, under the conditions of our experiment, upward matter is seen as faster than downward for speeds greater than approx.1 deg/sec, but the effect appears to reverse at speeds below approx.1 deg/sec with downward motion perceived as faster. Given that an up-down asymmetry has been observed for the optokinetic response, both perceptual and oculomotor contributions to this phenomenon deserve exploration.
NASA Technical Reports Server (NTRS)
Rorie, Conrad; Fern, Lisa; Pack, Jessica; Shively, Jay; Draper, Mark H.
2015-01-01
The pilot-in-the-loop Detect-and-Avoid (DAA) task requires the pilot to carry out three major functions: 1) detect a potential threat, 2) determine an appropriate resolution maneuver, and 3) execute that resolution maneuver via the GCS control and navigation interface(s). The purpose of the present study was to examine two main questions with respect to DAA display considerations that could impact pilots ability to maintain well clear from other aircraft. First, what is the effect of a minimum (or basic) information display compared to an advanced information display on pilot performance? Second, what is the effect of display location on UAS pilot performance? Two levels of information level (basic, advanced) were compared across two levels of display location (standalone, integrated), for a total of four displays. The results indicate that the advanced displays had faster overall response times compared to the basic displays, however, there were no significant differences between the standalone and integrated displays.
Higher integrity of the motor and visual pathways in long-term video game players.
Zhang, Yang; Du, Guijin; Yang, Yongxin; Qin, Wen; Li, Xiaodong; Zhang, Quan
2015-01-01
Long term video game players (VGPs) exhibit superior visual and motor skills compared with non-video game control subjects (NVGCs). However, the neural basis underlying the enhanced behavioral performance remains largely unknown. To clarify this issue, the present study compared the whiter matter integrity within the corticospinal tracts (CST), the superior longitudinal fasciculus (SLF), the inferior longitudinal fasciculus (ILF), and the inferior fronto-occipital fasciculus (IFOF) between the VGPs and the NVGCs using diffusion tensor imaging. Compared with the NVGCs, voxel-wise comparisons revealed significantly higher fractional anisotropy (FA) values in some regions within the left CST, left SLF, bilateral ILF, and IFOF in VGPs. Furthermore, higher FA values in the left CST at the level of cerebral peduncle predicted a faster response in visual attention tasks. These results suggest that higher white matter integrity in the motor and higher-tier visual pathways is associated with long-term video game playing, which may contribute to the understanding on how video game play influences motor and visual performance.
Higher integrity of the motor and visual pathways in long-term video game players
Du, Guijin; Yang, Yongxin; Qin, Wen; Li, Xiaodong; Zhang, Quan
2015-01-01
Long term video game players (VGPs) exhibit superior visual and motor skills compared with non-video game control subjects (NVGCs). However, the neural basis underlying the enhanced behavioral performance remains largely unknown. To clarify this issue, the present study compared the whiter matter integrity within the corticospinal tracts (CST), the superior longitudinal fasciculus (SLF), the inferior longitudinal fasciculus (ILF), and the inferior fronto-occipital fasciculus (IFOF) between the VGPs and the NVGCs using diffusion tensor imaging. Compared with the NVGCs, voxel-wise comparisons revealed significantly higher fractional anisotropy (FA) values in some regions within the left CST, left SLF, bilateral ILF, and IFOF in VGPs. Furthermore, higher FA values in the left CST at the level of cerebral peduncle predicted a faster response in visual attention tasks. These results suggest that higher white matter integrity in the motor and higher-tier visual pathways is associated with long-term video game playing, which may contribute to the understanding on how video game play influences motor and visual performance. PMID:25805981
Whipple, Brittany D; Nelson, Jason M
2016-02-01
This study investigated the performance of adolescents and young adults with Attention Deficit Hyperactivity Disorder (ADHD), Reading Disorder (RD), and ADHD/RD on measures of alphanumeric and nonalphanumeric naming speed and the relationship between naming speed and academic achievement. The sample (N = 203) included students aged 17-28 years diagnosed with ADHD (n = 83), RD (n = 71), or ADHD/RD (n = 49). Individuals with ADHD performed significantly faster on measures of alphanumeric naming compared with RD and comorbid groups and, within group, demonstrated significantly quicker naming of letters/digits compared with colors/objects. Both alphanumeric rapid naming scores and processing speed scores variably predicted academic achievement scores across groups, whereas nonalphanumeric rapid naming only predicted reading comprehension scores within the ADHD group. Results support findings that older individuals with ADHD show relative weakness in rapid naming of objects and colors. Implications of these findings in regard to assessment of older individuals for ADHD are discussed. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Pinedo, Pablo; Karreman, Hubert; Bothe, Hans; Velez, Juan; Risco, Carlos
2013-01-01
The objective was to evaluate the efficacy of a botanical product (PHYTO-MAST®) for the intra-mammary treatment of clinical mastitis (CM) in dairy cows managed in an organic system. The study involved 194 naturally occurring cases of clinical mastitis. Treatment was applied every 12 hours for 3 days and cows were evaluated for clinical cure starting on day 4. Outcomes of interest consisted of mastitis resolution at day 4, time to resolution, somatic cell score (SCS) after recovery, and bacteriological cure at 14 and 28 d after treatment. There was no significant effect on clinical mastitis resolution at day 4 for treatment compared with the control group. However, there was a faster recovery for the treatment group compared to the control group with median intervals from end of treatment to recovery of 4.6 d and 6.5 d, respectively. There was no effect on the probability of a SCS < 4 (200 000 SC/mL) after treatment. No significant effects were found for treatment on bacteriological cure at days 14 and 28. PMID:24155432
Preventing the common cold with a vitamin C supplement: a double-blind, placebo-controlled survey.
Van Straten, Michael; Josling, Peter
2002-01-01
One hundred sixty-eight volunteers were randomized to receive a placebo or a vitamin C supplement, two tablets daily, over a 60-day period between November and February. They used a five-point scale to assess their health and recorded any common cold infections and symptoms in a daily diary. Compared with the placebo group, the active-treatment group had significantly fewer colds (37 vs 50, P<.05), fewer days challenged virally (85 vs 178), and a significantly shorter duration of severe symptoms (1.8 vs 3.1 days, P<.03). Consequently, volunteers in the active group were less likely to get a cold and recovered faster if infected. Few side effects occurred with the active treatment, and volunteers reported greatly increased satisfaction with the study supplement compared with any previous form of vitamin C. This well-tolerated vitamin C supplement may prevent the common cold and shorten the duration of symptoms. Volunteers were generally impressed by the protection afforded them during the winter months and the general acceptability of the study medication.
Suitability of the echo-time-shift method as laboratory standard for thermal ultrasound dosimetry
NASA Astrophysics Data System (ADS)
Fuhrmann, Tina; Georg, Olga; Haller, Julian; Jenderka, Klaus-Vitold
2017-03-01
Ultrasound therapy is a promising, non-invasive application with potential to significantly improve cancer therapies like surgery, viro- or immunotherapy. This therapy needs faster, cheaper and more easy-to-handle quality assurance tools for therapy devices as well as possibilities to verify treatment plans and for dosimetry. This limits comparability and safety of treatments. Accurate spatial and temporal temperature maps could be used to overcome these shortcomings. In this contribution first results of suitability and accuracy investigations of the echo-time-shift method for two-dimensional temperature mapping during and after sonication are presented. The analysis methods used to calculate time-shifts were a discrete frame-to-frame and a discrete frame-to-base-frame algorithm as well as a sigmoid fit for temperature calculation. In the future accuracy could be significantly enhanced by using continuous methods for time-shift calculation. Further improvements can be achieved by improving filtering algorithms and interpolation of sampled diagnostic ultrasound data. It might be a comparatively accurate, fast and affordable method for laboratory and clinical quality control.
McMorris, Terry; Sproule, John; Turner, Anthony; Hale, Beverley J
2011-03-01
The purpose of this study was to compare, using meta-analytic techniques, the effect of acute, intermediate intensity exercise on the speed and accuracy of performance of working memory tasks. It was hypothesized that acute, intermediate intensity exercise would have a significant beneficial effect on response time and that effect sizes for response time and accuracy data would differ significantly. Random-effects meta-analysis showed a significant, beneficial effect size for response time, g=-1.41 (p<0.001) but a significant detrimental effect size, g=0.40 (p<0.01), for accuracy. There was a significant difference between effect sizes (Z(diff)=3.85, p<0.001). It was concluded that acute, intermediate intensity exercise has a strong beneficial effect on speed of response in working memory tasks but a low to moderate, detrimental one on accuracy. There was no support for a speed-accuracy trade-off. It was argued that exercise-induced increases in brain concentrations of catecholamines result in faster processing but increases in neural noise may negatively affect accuracy. 2010 Elsevier Inc. All rights reserved.
Romero-Vivas, C M; Llinás, H; Falconar, A K
2015-03-01
To confirm that a single water-surface sweep-net collection coupled with three calibration factors (2.6, 3.0 and 3.5 for 1/3, 2/3 and 3/3 water levels, respectively) (WSCF) could accurately estimate very low to high Aedes aegypti pupae numbers in water containers more rapidly than the exhaustive 5-sweep and total count (ESTC) method recommended by WHO. Both methods were compared in semi-field trials using low (n = 25) to moderate (n = 50-100) pupae numbers in a 250-l drum at 1/3, 2/3 and 3/3 water levels, and by their mean-time determinations using 200 pupae in three 220- to 1024-l water containers at these water levels. Accuracy was further assessed using 69.1% (393/569) of the field-based drums and tanks which contained <100 pupae. The WSCF method accurately estimated total populations in the semi-field trials up to 13.0 times faster than the ESTC method (all P < 0.001); no significant differences (all P-values ≥ 0.05) were obtained between the methods for very low (n = 4) to low-moderate (n = 25-100) and high (n > 100) pupae numbers/container and without sediment disturbance. The simple WSCF method sensitively, accurately and robustly estimated total pupae numbers in their principal breeding sites worldwide, containers with >20 l water volumes, significantly (2.7- to 13.0-fold: all P-values <0.001) faster than the ESTC method for very low to high pupae numbers/container without contaminating the clean water by sediment disturbance which is generated using the WHO-recommended ESTC method. The WSCF method seems ideal for global community-based surveillance and control programmes. © 2014 John Wiley & Sons Ltd.
Vigmond, Edward J.; Boyle, Patrick M.; Leon, L. Joshua; Plank, Gernot
2014-01-01
Simulations of cardiac bioelectric phenomena remain a significant challenge despite continual advancements in computational machinery. Spanning large temporal and spatial ranges demands millions of nodes to accurately depict geometry, and a comparable number of timesteps to capture dynamics. This study explores a new hardware computing paradigm, the graphics processing unit (GPU), to accelerate cardiac models, and analyzes results in the context of simulating a small mammalian heart in real time. The ODEs associated with membrane ionic flow were computed on traditional CPU and compared to GPU performance, for one to four parallel processing units. The scalability of solving the PDE responsible for tissue coupling was examined on a cluster using up to 128 cores. Results indicate that the GPU implementation was between 9 and 17 times faster than the CPU implementation and scaled similarly. Solving the PDE was still 160 times slower than real time. PMID:19964295
Miller, Karen; Hall, Brian; Tobias, Joseph D
2017-01-01
Sugammadex is a novel agent for the reversal of neuromuscular blockade. The speed and efficacy of reversal with sugammadex are significantly faster than acetylcholinesterase inhibitors, such as neostigmine. Sugammadex also has a limited adverse profile when compared with acetylcholinesterase inhibitors, specifically in regard to the incidence of bradycardia. This adverse effect may be particularly relevant in the setting of a heart transplant recipient with a denervated heart. The authors present a case of an 8-year-old child, status postcardiac transplantation, who required anesthetic care for laparoscopy and lysis of intra-abdominal adhesions. Sugammadex was used to reverse neuromuscular blockade and avoid the potential adverse effects of neostigmine. The unique mechanism of action of sugammadex is discussed, previous reports of its use in this unique patient population are reviewed, and its potential benefits compared to traditional acetylcholinesterase inhibitors are presented. PMID:28701612
Miller, Karen; Hall, Brian; Tobias, Joseph D
2017-01-01
Sugammadex is a novel agent for the reversal of neuromuscular blockade. The speed and efficacy of reversal with sugammadex are significantly faster than acetylcholinesterase inhibitors, such as neostigmine. Sugammadex also has a limited adverse profile when compared with acetylcholinesterase inhibitors, specifically in regard to the incidence of bradycardia. This adverse effect may be particularly relevant in the setting of a heart transplant recipient with a denervated heart. The authors present a case of an 8-year-old child, status postcardiac transplantation, who required anesthetic care for laparoscopy and lysis of intra-abdominal adhesions. Sugammadex was used to reverse neuromuscular blockade and avoid the potential adverse effects of neostigmine. The unique mechanism of action of sugammadex is discussed, previous reports of its use in this unique patient population are reviewed, and its potential benefits compared to traditional acetylcholinesterase inhibitors are presented.
Rapid, cool sintering of wet processed yttria-stabilized zirconia ceramic electrolyte thin films.
Park, Jun-Sik; Kim, Dug-Joong; Chung, Wan-Ho; Lim, Yonghyun; Kim, Hak-Sung; Kim, Young-Beom
2017-09-29
Here we report a photonic annealing process for yttria-stabilized zirconia films, which are one of the most well-known solid-state electrolytes for solid oxide fuel cells (SOFCs). Precursor films were coated using a wet-chemical method with a simple metal-organic precursor solution and directly annealed at standard pressure and temperature by two cycles of xenon flash lamp irradiation. The residual organics were almost completely decomposed in the first pre-annealing step, and the fluorite crystalline phases and good ionic conductivity were developed during the second annealing step. These films showed properties comparable to those of thermally annealed films. This process is much faster than conventional annealing processes (e.g. halogen furnaces); a few seconds compared to tens of hours, respectively. The significance of this work includes the treatment of solid-state electrolyte oxides for SOFCs and the demonstration of the feasibility of other oxide components for solid-state energy devices.
Semantic priming of familiar songs.
Johnson, Sarah K; Halpern, Andrea R
2012-05-01
We explored the functional organization of semantic memory for music by comparing priming across familiar songs both within modalities (Experiment 1, tune to tune; Experiment 3, category label to lyrics) and across modalities (Experiment 2, category label to tune; Experiment 4, tune to lyrics). Participants judged whether or not the target tune or lyrics were real (akin to lexical decision tasks). We found significant priming, analogous to linguistic associative-priming effects, in reaction times for related primes as compared to unrelated primes, but primarily for within-modality comparisons. Reaction times to tunes (e.g., "Silent Night") were faster following related tunes ("Deck the Hall") than following unrelated tunes ("God Bless America"). However, a category label (e.g., Christmas) did not prime tunes from within that category. Lyrics were primed by a related category label, but not by a related tune. These results support the conceptual organization of music in semantic memory, but with potentially weaker associations across modalities.
Adnan, Mehnaz; Peterkin, Donald; Lopez, Liza; Mackereth, Graham
2017-02-01
Electronic reporting of Influenza-like illness (eILI) from primary care was implemented and evaluated in three general medical practices in New Zealand during May to September 2015. To measure the uptake of eILI and to identify the system's strength and limitations. Analysis of transactional data from the eILI system; comparative study of influenza-like illness cases reported using manual methods and eILI; questionnaire administered to clinical and operational stakeholders. Over the study period 66% of total ILI cases were reported using eILI. Reporting timeliness improved significantly compared to manual reporting with an average of 24 minutes from submission by the clinician to processing in the national database. Users found the system to be user-friendly. eILI assists clinicians to report ILI cases to public health authorities within a stipulated time period and is associated with faster, more reliable and improved information transfer.
Ma, Li; Stübinger, Stefan; Liu, Xi Ling; Schneider, Urs A; Lang, Niklaus P
2013-08-01
The purpose of this study was to compare bone healing of experimental osteotomies applying either piezosurgery or two different oscillating saw blades in a rabbit model. The 16 rabbits were randomly assigned into four groups to comply with observation periods of one, two, three and five weeks. In all animals, four osteotomy lines were performed on the left and right nasal bone using a conventional saw blade, a novel saw blade and piezosurgery. All three osteotomy techniques revealed an advanced gap healing starting after one week. The most pronounced new bone formation took place between two and three weeks, whereby piezoelectric surgery revealed a tendency to faster bone formation and remodelling. Yet, there were no significant differences between the three modalities. The use of a novel as well as the piezoelectric bone-cutting instrument revealed advanced bone healing with a favourable surgical performance compared to a traditional saw.
Temperature & wood source control PyOM turnover in a Northern American forest
NASA Astrophysics Data System (ADS)
Hatton, Pierre-Joseph; Le Moine, James; Auclerc, Apolline; Gormley, Mark; Filley, Tim R.; Nadelhoffer, Knute J.; Bird, Jeff. A.
2016-04-01
Surprisingly little is known about how pyrolysis temperature and wood source affect the stability of forest-fire derived pyrogenic organic matter (PyOM). Here, we show that wood source and temperature affect in situ mineralization rates of PyOM in soils for two co-occurring gymnosperm (jack pine; JP [Pinus banksiana]) and angiosperm (red maple; RM [Acer rubrum])¬ species from North American boreal-temperate ecotones. We assess the effect of pyrolysis temperature on PyOM fates by following the decay of 13C/15N-enriched JP wood (JPwood) and PyOM produced at 300 °C (JP300) and 450 °C (JP450); and assess the effect of PyOM wood source by comparing fates of JP450 and RM450. JPwood mineralized 18× faster than JP300 and 44× faster than JP450 after 2.8y. RM450 mineralized initially faster than JP450 during the first ~2y, but became equivalent afterwards (1.1±0.2% of CO¬2 losses after 2.8y). Modeled turnover times suggest that this can be attributed to ~1% of fast-cycling PyOM (<3y). Slower-cycling pools are 12× faster for JPwood (13±5y) than for JP300 (157±28y) and 55× faster than for JP450 (700±229y). Modeled turnover times of the slow-cycling pools were equivalent for JP450 and RM450. The priming effect was positive for JPwood (0.10±0.05), neutral for JP300 (-0.02±0.04), and negative for JP450 (-0.15±0.03) and RM50 (-0.59±0.03). DOC losses were minimal compared with CO2 losses (DOC:CO2 ratio ≤0.005), but followed the same patterns: JPwood 6× greater than that of JP300 and 39× greater compared with JP450. After 1y, C recoveries were lower for JPwood than for PyOM, with no influence of pyrolysis temperature or wood source (yet); N recoveries did not differ. PLFA-(13)C data reveal that (i) treatments have similar microbial communities after 1y, (ii) JPwood is preferentially utilized by fungi, and (iii) bacteria increasingly utilize PyOM as pyrolysis temperature increases. Estimated carbon use efficiency decreased with increasing pyrolysis temperature (JPwood~JP300>JP450~RM450). Although insignificant, potential phenol oxidase and peroxidase activities decrease with increasing pyrolysis temperature. Neither PyOM nor wood additions (~11% of soil C stock 0-20 cm depth) affected pH or Ec after 1y. We provide the first, field experimental evidence that pyrolysis temperature and wood source affect the turnover of PyOM in soil. We show faster, initial decay for PyOM produced at lesser temperature and RM (angiosperm) compared with JP (gymnosperm). This study offers realistic insights on (i) the controls underlying in situ PyOM turnover, and on (ii) how ongoing/projected changes in tree species composition and fire frequency/intensity/distribution may affect PyOM in soil of North America temperate-boreal ecotones.
Pech, Melissa; O'Kearney, Richard
2013-01-01
Study Objectives: To compare the efficacy of problem-solving therapy (PST) combined with behavioral sleep strategies to standard cognitive therapy (CT) combined with behavioral sleep strategies in the treatment of insomnia. Design: A six-week randomized controlled trial with one month follow-up. Setting: The Australian National University Psychology Clinic, Canberra, Australia. Participants: Forty-seven adults aged 18-60 years recruited from the community meeting the Research Diagnostic Criteria for insomnia. Interventions: Participants received 6 weeks of treatment including one group session (sleep education and hygiene, stimulus control instructions and progressive muscle relaxation) followed by 5 weeks of individual treatment of PST or CT. Measurements and Results: Primary outcomes included sleep efficiency (SE) from sleep diaries, the Insomnia Severity Index (ISI), and the Pittsburgh Sleep Quality Index (PSQI). Secondary measures assessed dysfunctional sleep beliefs, problem-solving skills and orientations, and worry. Both treatments produced significant post therapy improvements in sleep which were maintained at 1 month follow-up (on SE Cohen d = 1.42, 95% CI 1.02-1.87 for PST; d = 1.26, 95% CI 0.81-1.65 for CT; on ISI d = 1.46, 95% CI 1.03-1.88 for PST; d = 1.95, 95% CI 0.52-2.38 for CT; for PSQI d = 0.97, 95% CI 0.55-1.40 for PST and d = 1.34, 95% CI 0.90-1.79 for the CT). There were no differences in PST and CT in the size or rate of improvement in sleep although CT produced a significant faster rate of decline in negative beliefs about sleep than PST and there was a trend (P = 0.08) for PST to produce a faster rate of improvement in negative problem orientation than CT. Conclusions: The results provide preliminary support for problem solving treatment as an equally efficacious alternative component to cognitive therapy in psychological interventions for insomnia. Citation: Pech M; O'Kearney R. A randomized controlled trial of problem-solving therapy compared to cognitive therapy for the treatment of insomnia in adults. SLEEP 2013;36(5):739-749. PMID:23633757
Martin, Vincent; Ratel, Sébastien; Siracusa, Julien; Le Ruyet, Pascale; Savary-Auzeloux, Isabelle; Combaret, Lydie; Guillet, Christelle; Dardevet, Dominique
2013-01-01
The purpose of this study was to investigate the effect of whey supplementation, as compared to the standard casein diet, on the recovery of muscle functional properties after a casting-induced immobilization period. After an initial (I0) evaluation of the contractile properties of the plantarflexors (isometric torque-frequency relationship, concentric power-velocity relationship and a fatigability test), the ankle of 20 male adult rats was immobilized by casting for 8 days. During this period, rats were fed a standard diet with 13% of casein (CAS). After cast removal, rats received either the same diet or a diet with 13% of whey proteins (WHEY). A control group (n = 10), non-immobilized but pair-fed to the two other experimental groups, was also studied and fed with the CAS diet. During the recovery period, contractile properties were evaluated 7 (R7), 21 (R21) and 42 days (R42) after cast removal. The immobilization procedure induced a homogeneous depression of average isometric force at R7 (CAS: − 19.0±8.2%; WHEY: − 21.7±8.4%; P<0.001) and concentric power (CAS: − 26.8±16.4%, P<0.001; WHEY: − 13.5±21.8%, P<0.05) as compared to I0. Conversely, no significant alteration of fatigability was observed. At R21, isometric force had fully recovered in WHEY, especially for frequencies above 50 Hz, whereas it was still significantly depressed in CAS, where complete recovery occurred only at R42. Similarly, recovery of concentric power was faster at R21 in the 500−700°/s range in the WHEY group. These results suggest that recovery kinetics varied between diets, the diet with the whey proteins promoting a faster recovery of isometric force and concentric power output as compared to the casein diet. These effects were more specifically observed at force level and movement velocities that are relevant for functional abilities, and thus natural locomotion. PMID:24069411
Impact of metabolic syndrome on progression of aortic stenosis: influence of age and statin therapy.
Capoulade, Romain; Clavel, Marie-Annick; Dumesnil, Jean G; Chan, Kwan L; Teo, Koon K; Tam, James W; Côté, Nancy; Mathieu, Patrick; Després, Jean-Pierre; Pibarot, Philippe
2012-07-17
The aims of this study were to examine prospectively the relationship between metabolic syndrome (MetS) and aortic stenosis (AS) progression and to evaluate the effect of age and statin therapy on AS progression in patients with or without MetS. Despite the clear benefits of statin therapy in primary and secondary coronary heart disease prevention, several recent randomized trials have failed to demonstrate any significant effect of this class of drugs on the progression of AS. Previous retrospective studies have reported an association between MetS and faster AS progression. This predefined substudy included 243 of the 269 patients enrolled in the ASTRONOMER (AS Progression Observation: Measuring Effects of Rosuvastatin) trial. Follow-up was 3.4 ± 1.3 years. AS progression rate was measured by calculating the annualized increase in peak aortic jet velocity measured by Doppler echocardiography. Patients with MetS (27%) had faster stenosis progression (+0.25 ± 0.21 m/s/year vs. +0.19 ± 0.19 m/s/year, p = 0.03). Predictors of faster AS progression in multivariate analysis were older age (p = 0.01), higher degree of valve calcification (p = 0.01), higher peak aortic jet velocity at baseline (p = 0.007), and MetS (p = 0.005). Impact of MetS on AS progression was most significant in younger (< 57 years) patients (MetS: +0.24 ± 0.19 m/s/year vs. no MetS: +0.13 ± 0.18 m/s/year, p = 0.008) and among patients receiving statin therapy (+0.27 ± 0.23 m/s/year vs. +0.19 ± 0.18 m/s/year, p = 0.045). In multivariate analysis, the MetS-age interaction was significant (p = 0.01), but the MetS-statin use interaction was not. MetS was found to be a powerful and independent predictor of faster AS progression, with more pronounced impact in younger patients. These findings emphasize the importance of routinely identifying and treating MetS in AS patients. The apparent faster stenosis progression in the subset of normocholesterolemic patients with MetS receiving the statin will need to be confirmed by future studies. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Mokry, Theresa; Bellemann, Nadine; Müller, Dirk; Lorenzo Bermejo, Justo; Klauß, Miriam; Stampfl, Ulrike; Radeleff, Boris; Schemmer, Peter; Kauczor, Hans-Ulrich; Sommer, Christof-Matthias
2014-01-01
Objectives To evaluate accuracy of estimated graft size for living-related liver transplantation using a semi-automated interactive software for CT-volumetry. Materials and Methods Sixteen donors for living-related liver transplantation (11 male; mean age: 38.2±9.6 years) underwent contrast-enhanced CT prior to graft removal. CT-volumetry was performed using a semi-automated interactive software (P), and compared with a manual commercial software (TR). For P, liver volumes were provided either with or without vessels. For TR, liver volumes were provided always with vessels. Intraoperative weight served as reference standard. Major study goals included analyses of volumes using absolute numbers, linear regression analyses and inter-observer agreements. Minor study goals included the description of the software workflow: degree of manual correction, speed for completion, and overall intuitiveness using five-point Likert scales: 1–markedly lower/faster/higher for P compared with TR, 2–slightly lower/faster/higher for P compared with TR, 3–identical for P and TR, 4–slightly lower/faster/higher for TR compared with P, and 5–markedly lower/faster/higher for TR compared with P. Results Liver segments II/III, II–IV and V–VIII served in 6, 3, and 7 donors as transplanted liver segments. Volumes were 642.9±368.8 ml for TR with vessels, 623.8±349.1 ml for P with vessels, and 605.2±345.8 ml for P without vessels (P<0.01). Regression equations between intraoperative weights and volumes were y = 0.94x+30.1 (R2 = 0.92; P<0.001) for TR with vessels, y = 1.00x+12.0 (R2 = 0.92; P<0.001) for P with vessels, and y = 1.01x+28.0 (R2 = 0.92; P<0.001) for P without vessels. Inter-observer agreement showed a bias of 1.8 ml for TR with vessels, 5.4 ml for P with vessels, and 4.6 ml for P without vessels. For the degree of manual correction, speed for completion and overall intuitiveness, scale values were 2.6±0.8, 2.4±0.5 and 2. Conclusions CT-volumetry performed with P can predict accurately graft size for living-related liver transplantation while improving workflow compared with TR. PMID:25330198
Vaghadia, H; McLeod, D H; Mitchell, G W; Merrick, P M; Chilvers, C R
1997-01-01
A randomized, single-blind trial of two spinal anesthetic solutions for outpatient laparoscopy was conducted to compare intraoperative conditions and postoperative recovery. Thirty women (ASA physical status I and II) were assigned to one of two groups. Group I patients received a small-dose hypobaric solution of 1% lidocaine 25 mg made up to 3 mL by the addition of fentanyl 25 micrograms. Group II patients received a conventional-dose hyperbaric solution of 5% lidocaine 75 mg (in 7.5% dextrose) made up to 3 mL by the addition of 1.5 mL 10% dextrose. All patients received 500 mL of crystalloid preloading. Spinal anesthesia was performed at L2-3 or L3-4 with a 27-gauge Quincke point needle. Surgery commenced when the level of sensory anesthesia reached T-6. Intraoperative hypotension requiring treatment with ephedrine occurred in 54% of Group II patients but not in any Group I patients. Median (range) time for full motor recovery was 50 (0-95) min in Group I patients compared to 90 (50-120) min in Group II patients (P = 0.0005). Sensory recovery also occurred faster in Group I patients (100 +/- 22 min) compared with Group II patients (140 +/- 27 min, P = 0.0001). Postoperative headache occurred in 38% of all patients and 70% of these were postural in nature. Oral analgesia was the only treatment required. Spinal anesthesia did not result in a significant incidence of postoperative backache. On follow-up, 96% said they found spinal needle insertion acceptable, 93% found surgery comfortable, and 90% said they would request spinal anesthesia for laparoscopy in future. Overall, this study found spinal anesthesia for outpatient laparoscopy to have high patient acceptance and a comparable complication rate to other studies. The small-dose hypobaric lidocaine-fentanyl technique has advantages over conventional-dose hyperbaric lidocaine of no hypotension and faster recovery.
Monstrey, S; Beele, H; Kettler, M; Van Landuyt, K; Blondeel, P; Matton, G; Naeyaert, J M
1999-09-01
Improved shock therapy has extended the limits of survival in patients with massive burns, and nowadays skin coverage has become the major problem in burn management. The use of mesh skin grafts is still the simplest technique to expand the amount of available donor skin. However, very wide-mesh skin grafts take a very long time to heal, often resulting in unaesthetic scar formation. On the other hand, allogeneic cultured keratinocytes have been reported as a natural source of growth factors and thus could be useful to improve wound healing of these wide-mesh grafts. A clinical study was performed to compare the use of cryopreserved allogeneic cultured keratinocytes vs. the traditional cadaveric skin as a double layer over widely expanded autogenous skin grafts. This procedure was performed in 18 pairs of full-thickness burn wounds (with similar depth and location) in 11 severely burned patients. Early clinical evaluation was made at 2, 3, and 4 to 5 weeks. Parameters such as epithelialization, granulation tissue formation, infection, and scar formation were evaluated. Biopsies were taken to compare the histological characteristics of the epidermis, the epidermal-dermal junction, and the dermis. Late evaluations were performed at 6 and 12 months regarding color, softness, thickness, and subjective feeling of the scar tissue. Aside from a faster (p < 0.05) epithelialization in the keratinocyte group at 2 weeks, there were no statistically different results in any of the early evaluated parameters, neither clinically nor histologically. At long-term follow-up, clinical results and scar characteristics were not significantly different in the two compared groups. It is concluded from the results of this study that, during the early phase, epithelialization was faster with allogeneic cultured keratinocytes compared with cadaveric skin. However, taking into account the substantial difference in costs, the described use of cryopreserved allogeneic cultured keratinocytes as a double layer on meshed autogenous split-thickness skin grafts can hardly be advocated.
Cento, Valeria; Nguyen, Thi Huyen Tram; Di Carlo, Domenico; Biliotti, Elisa; Gianserra, Laura; Lenci, Ilaria; Di Paolo, Daniele; Calvaruso, Vincenza; Teti, Elisabetta; Cerrone, Maddalena; Romagnoli, Dante; Melis, Michela; Danieli, Elena; Menzaghi, Barbara; Polilli, Ennio; Siciliano, Massimo; Nicolini, Laura Ambra; Di Biagio, Antonio; Magni, Carlo Federico; Bolis, Matteo; Antonucci, Francesco Paolo; Di Maio, Velia Chiara; Alfieri, Roberta; Sarmati, Loredana; Casalino, Paolo; Bernardini, Sergio; Micheli, Valeria; Rizzardini, Giuliano; Parruti, Giustino; Quirino, Tiziana; Puoti, Massimo; Babudieri, Sergio; D’Arminio Monforte, Antonella; Andreoni, Massimo; Craxì, Antonio; Angelico, Mario; Pasquazzi, Caterina; Taliani, Gloria; Guedj, Jeremie; Ceccherini-Silberstein, Francesca
2017-01-01
Background Intracellular HCV-RNA reduction is a proposed mechanism of action of direct-acting antivirals (DAAs), alternative to hepatocytes elimination by pegylated-interferon plus ribavirin (PR). We modeled ALT and HCV-RNA kinetics in cirrhotic patients treated with currently-used all-DAA combinations to evaluate their mode of action and cytotoxicity compared with telaprevir (TVR)+PR. Study design Mathematical modeling of ALT and HCV-RNA kinetics was performed in 111 HCV-1 cirrhotic patients, 81 treated with all-DAA regimens and 30 with TVR+PR. Kinetic-models and Cox-analysis were used to assess determinants of ALT-decay and normalization. Results HCV-RNA kinetics was biphasic, reflecting a mean effectiveness in blocking viral production >99.8%. The first-phase of viral-decline was faster in patients receiving NS5A-inhibitors compared to TVR+PR or sofosbuvir+simeprevir (p<0.001), reflecting higher efficacy in blocking assembly/secretion. The second-phase, noted δ and attributed to infected-cell loss, was faster in patients receiving TVR+PR or sofosbuvir+simeprevir compared to NS5A-inhibitors (0.27 vs 0.21 d-1, respectively, p = 0.0012). In contrast the rate of ALT-normalization, noted λ, was slower in patients receiving TVR+PR or sofosbuvir+simeprevir compared to NS5A-inhibitors (0.17 vs 0.27 d-1, respectively, p<0.001). There was no significant association between the second-phase of viral-decline and ALT normalization rate and, for a given level of viral reduction, ALT-normalization was more profound in patients receiving DAA, and NS5A in particular, than TVR+PR. Conclusions Our data support a process of HCV-clearance by all-DAA regimens potentiated by NS5A-inhibitor, and less relying upon hepatocyte death than IFN-containing regimens. This may underline a process of “cell-cure” by DAAs, leading to a fast improvement of liver homeostasis. PMID:28545127
Discharge measurements using a broad-band acoustic Doppler current profiler
Simpson, Michael R.
2002-01-01
The measurement of unsteady or tidally affected flow has been a problem faced by hydrologists for many years. Dynamic discharge conditions impose an unreasonably short time constraint on conventional current-meter discharge-measurement methods, which typically last a minimum of 1 hour. Tidally affected discharge can change more than 100 percent during a 10-minute period. Over the years, the U.S. Geological Survey (USGS) has developed moving-boat discharge-measurement techniques that are much faster but less accurate than conventional methods. For a bibliography of conventional moving-boat publications, see Simpson and Oltmann (1993, page 17). The advent of the acoustic Doppler current profiler (ADCP) made possible the development of a discharge-measurement system capable of more accurately measuring unsteady or tidally affected flow. In most cases, an ADCP discharge-measurement system is dramatically faster than conventional discharge-measurement systems, and has comparable or better accuracy. In many cases, an ADCP discharge-measurement system is the only choice for use at a particular measurement site. ADCP systems are not yet ?turnkey;? they are still under development, and for proper operation, require a significant amount of operator training. Not only must the operator have a rudimentary knowledge of acoustic physics, but also a working knowledge of ADCP operation, the manufacturer's discharge-measurement software, and boating techniques and safety.
Sentinel lymph node accumulation of Lymphoseek and Tc-99m-sulfur colloid using a “2-day” protocol☆
Wallace, Anne M.; Hoh, Carl K.; Limmer, Karl K.; Darrah, Denise D.; Schulteis, Gery; Vera, David R.
2014-01-01
Lymphoseek is a receptor-binding radiopharmaceutical specifically designed for sentinel lymph node (SLN) mapping. We conducted a clinical trial which measured the injection site clearance and sentinel lymph node accumulation after a single intradermal injection of Lymphoseek or unfiltered [99mTc]sulfur colloid (TcSC) using a “2-day” protocol for SLN mapping of breast cancer. Eleven patients with breast cancer participated in this study. Five patients received an intradermal administration of 1.0 nmol of 99mTc-labeled Lymphoseek; SLN mapping was performed on four subjects within 19 to 27 h. Six subjects received an intradermal administration of TcSC; SLN mapping was performed on five subjects within 18 to 26 h. Lymphoseek exhibited a significantly (P<.001) faster injection site clearance than TcSC. The mean Lymphoseek clearance half-time was 2.18±1.09 h compared to 57.4±92.8 h for TcSC. The mean sentinel lymph node uptake of Lymphoseek (1.5±1.7%) and TcSC (3.5±3.1%) was statistically equivalent (P=.213). When an intradermal injection is employed, Lymphoseek demonstrated faster injection site clearance than unfiltered [99mTc]sulfur colloid and persistent SLN accumulation for at least 24 h. PMID:19647175
Physiological characteristics of elite short- and long-distance triathletes.
Millet, Grégoire P; Dréano, Patrick; Bentley, David J
2003-01-01
The purpose of this study was to compare the physiological responses in cycling and running of elite short-distance (ShD) and long-distance (LD) triathletes. Fifteen elite male triathletes participating in the World Championships were divided into two groups (ShD and LD) and performed a laboratory trial that comprised submaximal treadmill running, maximal then submaximal ergometry cycling and then an additional submaximal run. "In situ" best ShD triathlon performances were also analysed for each athlete. ShD demonstrated a significantly faster swim time than LD whereas .VO(2max) (ml kg(-1) min(-1)), cycling economy (W l(-1) min(-1)), peak power output (.W(peak),W) and ventilatory threshold (%.VO(2max)) were all similar between ShD and LD. Moreover, there were no differences between the two groups in the change (%) in running economy from the first to the second running bout. Swimming time was correlated to .W(peak)(r=-0.76; P<0.05) and economy ( r=-0.89; P<0.01) in the ShD athletes. Also, cycling time in the triathlon was correlated to .W(peak)(r=-0.83; P<0.05) in LD. In conclusion, ShD triathletes had a faster swimming time but did not exhibit different maximal or submaximal physiological characteristics measured in cycling and running than LD triathletes.
Kara, Cankat; Demir, Turgut; Ozbek, Elvan
2013-12-01
The aim of the present study was to assess the histopathological effects of low-level laser therapy (LLLT) on healing of the oral mucosa after soft tissue graft operations. The alterations at the end of healing in normal and LLLT-applied oral mucosa were studied in two healthy adult New Zealand white rabbits by taking specimens for light microscopic inspection. There was no adverse event reported in the study and no post-operative complications, such as swelling, bleeding, or edema, were observed in the rabbits. Complete wound healing was faster in the LLLT-applied rabbit. Compared to the normal rabbit oral mucosa, thickening of the stratum corneum (hyperkeratosis) was found in the epithelia of the rabbits. A significant increase in the epithelial thickness was found in the samples of rabbits, suggesting increased scar tissue following the wound repair. Additionally, many mitotic figures were present in the epithelia of the LLLT-applied rabbit, indicating epithelial cell hyperplasia. Long and irregular connective tissue protrusions projecting into the undersurface of the epithelium and mononuclear cell infiltrations were noted in the rabbits. The results suggest that LLLT used for soft tissue operations provides better and faster wound healing and that LLLT enhances epithelization.
Evolution of sperm structure and energetics in passerine birds
Rowe, Melissah; Laskemoen, Terje; Johnsen, Arild; Lifjeld, Jan T.
2013-01-01
Spermatozoa exhibit considerable interspecific variability in size and shape. Our understanding of the adaptive significance of this diversity, however, remains limited. Determining how variation in sperm structure translates into variation in sperm performance will contribute to our understanding of the evolutionary diversification of sperm form. Here, using data from passerine birds, we test the hypothesis that longer sperm swim faster because they have more available energy. We found that sperm with longer midpieces have higher levels of intracellular adenosine triphosphate (ATP), but that greater energy reserves do not translate into faster-swimming sperm. Additionally, we found that interspecific variation in sperm ATP concentration is not associated with the level of sperm competition faced by males. Finally, using Bayesian methods, we compared the evolutionary trajectories of sperm morphology and ATP content, and show that both traits have undergone directional evolutionary change. However, in contrast to recent suggestions in other taxa, we show that changes in ATP are unlikely to have preceded changes in morphology in passerine sperm. These results suggest that variable selective pressures are likely to have driven the evolution of sperm traits in different taxa, and highlight fundamental biological differences between taxa with internal and external fertilization, as well as those with and without sperm storage. PMID:23282997
In vitro and in vivo evaluation of capsaicin-loaded microemulsion for enhanced oral bioavailability.
Zhu, Yuan; Zhang, Jiajia; Zheng, Qianfeng; Wang, Miaomiao; Deng, Wenwen; Li, Qiang; Firempong, Caleb Kesse; Wang, Shengli; Tong, Shanshan; Xu, Ximing; Yu, Jiangnan
2015-10-01
Capsaicin, as a food additive, has attracted worldwide concern owing to its pungency and multiple pharmacological effects. However, poor water solubility and low bioavailability have limited its application. This study aims to develop a capsaicin-loaded microemulsion to enhance the oral bioavailability of the anti-neuropathic-pain component, capsaicin, which is poorly water soluble. In this study, the microemulsion consisting of Cremophor EL, ethanol, medium-chain triglycerides (oil phase) and water (external phase) was prepared and characterized (particle size, morphology, stability and encapsulation efficiency). The gastric mucosa irritation test of formulated capsaicin was performed in rats to evaluate its oral feasibility, followed by the pharmacokinetic study in vivo. Under these conditions, the encapsulated capsaicin revealed a faster capsaicin release in vitro coupled with a greater absorption in vivo when compared to the free capsaicin. The oral bioavailability of the formulated capsaicin-loaded microemulsions was 2.64-fold faster than that of free capsaicin. No significant irritation was observed on the mucosa from the pathological section of capsaicin-loaded microemulsion treated stomach. These results indicate that the developed microemulsion represents a safe and orally effective carrier for poorly soluble substances. The formulation could be used for clinical trials and expand the application of capsaicin. © 2014 Society of Chemical Industry.
Cache-Oblivious parallel SIMD Viterbi decoding for sequence search in HMMER.
Ferreira, Miguel; Roma, Nuno; Russo, Luis M S
2014-05-30
HMMER is a commonly used bioinformatics tool based on Hidden Markov Models (HMMs) to analyze and process biological sequences. One of its main homology engines is based on the Viterbi decoding algorithm, which was already highly parallelized and optimized using Farrar's striped processing pattern with Intel SSE2 instruction set extension. A new SIMD vectorization of the Viterbi decoding algorithm is proposed, based on an SSE2 inter-task parallelization approach similar to the DNA alignment algorithm proposed by Rognes. Besides this alternative vectorization scheme, the proposed implementation also introduces a new partitioning of the Markov model that allows a significantly more efficient exploitation of the cache locality. Such optimization, together with an improved loading of the emission scores, allows the achievement of a constant processing throughput, regardless of the innermost-cache size and of the dimension of the considered model. The proposed optimized vectorization of the Viterbi decoding algorithm was extensively evaluated and compared with the HMMER3 decoder to process DNA and protein datasets, proving to be a rather competitive alternative implementation. Being always faster than the already highly optimized ViterbiFilter implementation of HMMER3, the proposed Cache-Oblivious Parallel SIMD Viterbi (COPS) implementation provides a constant throughput and offers a processing speedup as high as two times faster, depending on the model's size.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosard, D.D.; Steltz, W.G.
1986-10-01
Properly sized turbine and boiler bypass systems permit two-shift cycling operation of units, shorten start-up time, and reduce life expenditures of plant components. With bypasses installed, faster startups can reduce fuel costs by $100,000 per year for a typical 500-MW fossil-fired unit. This report discusses the technical characteristics of existing bypass systems and provides guidelines for sizing bypass systems to achieve economical and reliable two-shift operation. The collection and analysis of startup data from several generating units were used in conjunction with computer simulations to illustrate the effects of adding various arrangements and sizes of steam bypass systems. The report,more » which indicates that shutdown procedures have significant impact on subsequent startup and loading time, describes operating practices to optimize the effectiveness of bypass systems. To determine the effectiveness of large turbine bypass systems of less than 100% capacity in preventing boiler trips following load rejection, transient field data were compared to a load rejection simulation using the modular modeling system (MMS). The MMS was then used to predict system response to other levels of load rejection. 7 refs., 87 figs., 8 tabs.« less
Kang, Hee E; Chung, Hye J; Kim, Hyung S; Lee, Jee W; Lee, Myung G
2010-01-31
It has been reported that both liquiritigenin (LQ) and dimethyl-4,4'-dimethoxy-5,6,5',6'-dimethylenedioxybiphenyl-2,2'-dicarboxylate (DDB) have a hepatoprotective effect, and administration of both drugs together shows additive protective effect against acute liver injuries. Therefore, the pharmacokinetic interaction between LQ and DDB in rats was studied. LQ (20 and 50mg/kg for the i.v. and p.o. administration, respectively), DDB (10mg/kg for both i.v. and p.o. administration), and both drugs together were once administered intravenously or orally to rats. After the i.v. administration of both drugs together, the Cl(nr) and AUC of LQ were significantly faster (by 30.5%) and smaller (by 22.5%), respectively, than those of without DDB due to the faster hepatic blood flow rate by DDB. After the p.o. administration of both drugs together, the AUC of LQ was comparable to that of without DDB due to negligible effect of DDB on intestinal metabolism of LQ. The pharmacokinetic parameters of DDB after both i.v. and p.o. administration were not altered by LQ, indicating that LQ did not considerably affect the pharmacokinetics of DDB in rats. Copyright 2009 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Afzalian, Aryan; Colinge, Jean-Pierre; Flandre, Denis
2011-05-01
A new concept of nanoscale MOSFET, the Gate Modulated Resonant Tunneling Transistor (RT-FET), is presented and modeled using 3D Non-Equilibrium Green's Function simulations enlightening the main physical mechanisms. Owing to the additional tunnel barriers and the related longitudinal confinement present in the device, the density of state is reduced in its off-state, while remaining comparable in its on-state, to that of a MOS transistor without barriers. The RT-FET thus features both a lower RT-limited off-current and a faster increase of the current with V G, i.e. an improved slope characteristic, and hence an improved Ion/ Ioff ratio. Such improvement of the slope can happen in subthreshold regime, and therefore lead to subthreshold slope below the kT/q limit. In addition, faster increase of current and improved slope occur above threshold and lead to high thermionic on-current and significant Ion/ Ioff ratio improvement, even with threshold voltage below 0.2 V and supply voltage V dd of a few hundreds of mV as critically needed for future technology nodes. Finally RT-FETs are intrinsically immune to source-drain tunneling and are therefore promising candidate for extending the roadmap below 10 nm.
Sexual species are separated by larger genetic gaps than asexual species in rotifers.
Tang, Cuong Q; Obertegger, Ulrike; Fontaneto, Diego; Barraclough, Timothy G
2014-10-01
Why organisms diversify into discrete species instead of showing a continuum of genotypic and phenotypic forms is an important yet rarely studied question in speciation biology. Does species discreteness come from adaptation to fill discrete niches or from interspecific gaps generated by reproductive isolation? We investigate the importance of reproductive isolation by comparing genetic discreteness, in terms of intra- and interspecific variation, between facultatively sexual monogonont rotifers and obligately asexual bdelloid rotifers. We calculated the age (phylogenetic distance) and average pairwise genetic distance (raw distance) within and among evolutionarily significant units of diversity in six bdelloid clades and seven monogonont clades sampled for 4211 individuals in total. We find that monogonont species are more discrete than bdelloid species with respect to divergence between species but exhibit similar levels of intraspecific variation (species cohesiveness). This pattern arises because bdelloids have diversified into discrete genetic clusters at a faster net rate than monogononts. Although sampling biases or differences in ecology that are independent of sexuality might also affect these patterns, the results are consistent with the hypothesis that bdelloids diversified at a faster rate into less discrete species because their diversification does not depend on the evolution of reproductive isolation. © 2014 The Authors. Evolution published by Wiley Periodicals, Inc. on behalf of The Society for the Study of Evolution.
Lamas-Pinheiro, Ruben; Mitzman, Francesca; Miranda, Alice; Henriques-Coelho, Tiago; Estevão-Costa, José; Correia-Pinto, Jorge
2016-04-01
External compression is used for pectus carinatum (PC) treatment, but many patients are noncompliant. Costal cartilage resection (CCR) has been described as an alternative, but these approaches sacrifice the internal thoracic arteries (ITA). We aim to assess the feasibility of CCR sparing ITA comparing thoracoscopic and subcutaneous endoscopic approaches. Twelve pigs were used as models for surgical PC correction and randomized for 2 groups: thoracoscopy (T) and subcutaneous (subpectoralis) endoscopy (SP). In both groups, CCR from 3rd 4th and 5th ribs was performed avoiding ITA damage. ITA preservation was confirmed by Doppler-ultrasound as well as postmortem injection of methylene blue. Four persons evaluated the procedures being difficult, using a 6-item modified validated scale. In both techniques, the procedure was accomplished in all animals sparing ITAs. CCR was faster in T than in SP (49±5 vs. 65±16minutes, p<0.05). T was classified as easier than SP (p<0.001) with a significantly higher score for all items, especially better image and tissue handling. Sparing the ITAs during CCR for correction of PC is feasible in a porcine model and might be a goal in humans. The thoracoscopic approach allows for a faster and easier procedure. Copyright © 2016 Elsevier Inc. All rights reserved.
O'Grady, Kathleen M; Power, Hollie A; Olson, Jaret L; Morhart, Michael J; Harrop, A Robertson; Watt, M Joe; Chan, K Ming
2017-10-01
Upper trunk obstetric brachial plexus injury can cause profound shoulder and elbow dysfunction. Although neuroma excision with interpositional sural nerve grafting is the current gold standard, distal nerve transfers have a number of potential advantages. The goal of this study was to compare the clinical outcomes and health care costs between nerve grafting and distal nerve transfers in children with upper trunk obstetric brachial plexus injury. In this prospective cohort study, children who underwent triple nerve transfers were followed with the Active Movement Scale for 2 years. Their outcomes were compared to those of children who underwent nerve graft reconstruction. To assess health care use, a cost analysis was also performed. Twelve patients who underwent nerve grafting were compared to 14 patients who underwent triple nerve transfers. Both groups had similar baseline characteristics and showed improved shoulder and elbow function following surgery. However, the nerve transfer group displayed significantly greater improvement in shoulder external rotation and forearm supination 2 years after surgery (p < 0.05). The operative time and length of hospital stay were significantly lower (p < 0.05), and the overall cost was approximately 50 percent less in the nerve transfer group. Triple nerve transfer for upper trunk obstetric brachial plexus injury is a feasible option, with better functional shoulder external rotation and forearm supination, faster recovery, and lower cost compared with traditional nerve graft reconstruction. Therapeutic, II.
Karell, Patrik; Bensch, Staffan; Ahola, Kari; Asghar, Muhammad
2017-07-26
Parasites are expected to exert long-term costs on host fecundity and longevity. Understanding the consequences of heritable polymorphic variation in disease defence in wild populations is essential in order to predict evolutionary responses to changes in disease risk. Telomeres have been found to shorten faster in malaria-diseased individuals compared with healthy ones with negative effects on longevity and thereby fitness. Here, we study the impact of haemosporidian blood parasites on telomere dynamics in tawny owls, which display a highly heritable plumage colour polymorphism. Previously, it has been shown that blood parasites have morph-specific impact on body mass maintenance. Here, we show that telomeres shortened faster in individuals with shorter breeding lifespan. Telomere length was negatively associated with the degree of pheomelanic brown coloration and shorter in infected than uninfected individuals. The rate of telomere shortening between breeding seasons was faster in darker pheomelanic individuals and suppression of parasite intensity between seasons was associated with faster telomere shortening in the paler individuals but not in darker ones. We propose that morph-specific physiological profiles cause differential telomere shortening and that this is likely to be a mechanism involved in previously documented environment-driven survival selection against the pheomelanic morph in this population. © 2017 The Author(s).
Comparison of open and laparoscopic preperitoneal repair of groin hernia.
Li, Jianwen; Wang, Xin; Feng, Xueyi; Gu, Yan; Tang, Rui
2013-12-01
Compared with laparoscopic groin herniorrhaphy, the open procedure used in most former studies was Lichtenstein repair. However, unlike the totally extraperitoneal (TEP) or transabdominal preperitoneal (TAPP) laparoscopic techniques, Lichtenstein procedure is a premuscular but not preperitoneal repair. This retrospective study compared the outcomes between laparoscopic preperitoneal and open preperitoneal procedure-modified Kugel (MK) herniorrhaphy. Groin hernia patients older than 18 years who underwent open MK or laparoscopic preperitoneal herniorrhaphy in our hospitals between January 2008 and December 2010 were enrolled. Baseline characteristics, recurrence, and intraoperative, short-term, and long-term postoperative complications were recorded. Among the 1,760 included patients (530 open and 1,230 laparoscopic), 96.08% completed the follow-up (24-60 months). The patients in the open group were older than laparoscopic group (p < 0.001). More bilateral (91.45%) and recurrent (82.12%) hernia patients underwent laparoscopic procedures (p < 0.001 and p = 0.004, respectively). The overall recurrence rate was 0.71%, with no significant difference between the two approaches (p = 0.227). The overall complication rate was lower for the laparoscopic than the open approach (14.47 vs. 19.25%, p = 0.012), whereas the rates of life-threatening complications were similar (1.51 vs. 0.98%, p = 0.332). The laparoscopic group had significantly lower incidence rates of wound infection and chronic pain (p = 0.016 and p < 0.001, respectively), shorter operative time, lower visual analogue scale scores, and faster recovery than the open group (p < 0.001). As preperitoneal herniorrhaphy, both MK and laparoscopic (TEP/TAPP) procedures are safe and effective, with low incidence rates of life-threatening complications and recurrence. The laparoscopic approach is superior in terms of lower incidence rates of infection and chronic pain, shorter operative time, and faster recovery; however, careful surgical procedure selection and implementation of technical details are required.
Zhu, Yuan-Gang; Dong, Shu-Ting; Zhang, Ji-Wang; Liu, Peng; Yang, Jin-Sheng; Jia, Chun-Lan; Liu, Jing-Guo; Li, Deng-Hai
2010-06-01
In order to investigate the effects of interplanting and direct seeding on the photosynthesis characteristics of summer maize and its utilization of solar and heat resources, two summer maize cultivars (Zhengdan 958 and Denghai 661) were planted in the farmlands of Denghai Seed Co. Ltd in Laizhou City of Shandong Province, with 67500 plants x hm(-2) and three sowing dates. The above-ground biomass, plant growth rate, leaf area index, and net photosynthetic rate per ear leaf were measured to reveal the photosynthesis characteristics of test cultivars. In the meantime, the characters of grain-filling were simulated by Richards' model, and the solar resource utilization efficiency of the cultivars was calculated, in combining with meteorological data. Comparing with interplanting, direct seeding increased the grain yield by 1.17%-3.33%, but decreased the thousand-grain weight significantly. Growth stages were extended under earlier sowing. The leaf area index and net photosynthetic rate from flowering to 30 d after anthesis were significantly higher under direct seeding than under interplanting, but after then, they decreased faster. Direct seeding induced a higher accumulation of dry matter and a faster plant growth rate before and after flowering. Under direct seeding, the maximum grain-filling rate reached earlier, the starting potential was higher, but the grain-filling period, active grain-filling period, and W(max) were lower, compared with those under interplanting. Also under direct seeding, the total accumulative temperature and solar radiation during growth period decreased by 150-350 degrees C x d and 200-400 MJ x m(-2), respectively, but the solar resource utilization efficiency of grain increased by 10.5%-24.7%. All the results suggested that direct seeding was superior to interplanting for the summer maize production under field condition. In order to enhance solar and heat utilization efficiency and excavate yield potential, it would be essential to improve the leaf photosynthesis efficiency and postpone leaf aging.
Mah, Wesley; Jiang, Guoqiao; Olver, Dylan; Cheung, Godwin; Kim, Ben; Larjava, Hannu; Häkkinen, Lari
2014-01-01
Scar formation following skin injury can be a major psychosocial and physiological problem. However, the mechanisms of scar formation are still not completely understood. Previous studies have shown that wound healing in oral mucosa is faster, associates with a reduced inflammatory response and results to significantly reduced scar formation compared with skin wounds. In the present study, we hypothesized that oral mucosal fibroblasts from human gingiva are inherently distinct from fibroblasts from breast and abdominal skin, two areas prone to excessive scar formation, which may contribute to the preferential wound healing outcome in gingiva. To this end, we compared the phenotype of human gingival and skin fibroblasts cultured in in vivo-like three-dimensional (3D) cultures that mimic the cells' natural extracellular matrix (ECM) niche. To establish 3D cultures, five parallel fibroblast lines from human gingiva (GFBLs) and breast skin (SFBLs) were seeded in high density, and cultured for up to 21 days in serum and ascorbic acid containing medium to induce expression of wound-healing transcriptome and ECM deposition. Cell proliferation, morphology, phenotype and expression of wound healing and scar related genes were analyzed by real-time RT-PCR, Western blotting and immunocytochemical methods. The expression of a set of genes was also studied in three parallel lines of human abdominal SFBLs. Findings showed that GFBLs displayed morphologically distinct organization of the 3D cultures and proliferated faster than SFBLs. GFBLs expressed elevated levels of molecules involved in regulation of inflammation and ECM remodeling (MMPs) while SFBLs showed significantly higher expression of TGF-β signaling, ECM and myofibroblast and cell contractility-related genes. Thus, GFBLs display an inherent phenotype conducive for fast resolution of inflammation and ECM remodeling, characteristic for scar-free wound healing, while SFBLs have a profibrotic, scar-prone phenotype. PMID:24608113
Pech, Melissa; O'Kearney, Richard
2013-05-01
To compare the efficacy of problem-solving therapy (PST) combined with behavioral sleep strategies to standard cognitive therapy (CT) combined with behavioral sleep strategies in the treatment of insomnia. A six-week randomized controlled trial with one month follow-up. The Australian National University Psychology Clinic, Canberra, Australia. Forty-seven adults aged 18-60 years recruited from the community meeting the Research Diagnostic Criteria for insomnia. Participants received 6 weeks of treatment including one group session (sleep education and hygiene, stimulus control instructions and progressive muscle relaxation) followed by 5 weeks of individual treatment of PST or CT. Primary outcomes included sleep efficiency (SE) from sleep diaries, the Insomnia Severity Index (ISI), and the Pittsburgh Sleep Quality Index (PSQI). Secondary measures assessed dysfunctional sleep beliefs, problem-solving skills and orientations, and worry. Both treatments produced significant post therapy improvements in sleep which were maintained at 1 month follow-up (on SE Cohen d = 1.42, 95% CI 1.02-1.87 for PST; d = 1.26, 95% CI 0.81-1.65 for CT; on ISI d = 1.46, 95% CI 1.03-1.88 for PST; d = 1.95, 95% CI 0.52-2.38 for CT; for PSQI d = 0.97, 95% CI 0.55-1.40 for PST and d = 1.34, 95% CI 0.90-1.79 for the CT). There were no differences in PST and CT in the size or rate of improvement in sleep although CT produced a significant faster rate of decline in negative beliefs about sleep than PST and there was a trend (P = 0.08) for PST to produce a faster rate of improvement in negative problem orientation than CT. The results provide preliminary support for problem solving treatment as an equally efficacious alternative component to cognitive therapy in psychological interventions for insomnia.
Bhatnagar, Vibha; O’Connor, Daniel T.; Schork, Nicholas J.; Salem, Rany M.; Nievergelt, Caroline M.; Rana, Brinda K.; Smith, Douglas W.; Bakris, George L.; Middleton, John P.; Norris, Keith C.; Wright, Jackson T.; Cheek, Deanna; Hiremath, Leena; Contreras, Gabriel; Appel, Lawrence J.; Lipkowitz, Michael S.
2009-01-01
Objective It has yet to be determined whether genotyping at the angiotensin-converting enzyme (ACE) locus is predictive of blood pressure response to an ACE inhibitor. Methods Participants from the African American Study of Kidney Disease and Hypertension trial randomized to the ACE inhibitor ramipril (n = 347) were genotyped at three polymorphisms on ACE, just downstream from the ACE insertion/deletion polymorphism (Ins/Del): G12269A, C17888T, and G20037A. Time to reach target mean arterial pressure (≤ 107 mmHg) was analyzed by genotype and ACE haplotype using Kaplan–Meier survival curves and Cox proportional hazard models. Results Individuals with a homozygous genotype at G12269A responded significantly faster than those with a heterozygous genotype; the adjusted (average number of medications and baseline mean arterial pressure) hazard ratio (homozygous compared to heterozygous genotype) was 1.86 (95% confidence limits 1.32–3.23; P < 0.001 for G12269A genotype). The adjusted hazard ratio for participants with homozygous ACE haplotypes compared to those heterozygous ACE haplotypes was 1.40 (1.13–1.75; P = 0.003 for haplotype). The ACE genotype effects were specific for ACE inhibition (i.e., not seen among those randomized to a calcium channel blocker), and were independent of population stratification. Conclusions African-Americans with a homozygous genotype at G12269A or homozygous ACE haplotypes responded to ramipril significantly faster than those with a heterozygous genotype or heterozygous haplotypes, suggesting that heterosis may be an important determinant of responsiveness to an ACE inhibitor. These associations may be a result of biological activity of this polymorphism, or of linkage disequilibrium with nearby variants such as the ACE Ins/Del, perhaps in the regulation of ACE splicing. PMID:17885551
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pobegalov, Georgii, E-mail: george.pobegalov@nanobio.spbstu.ru; Cherevatenko, Galina; Alekseev, Aleksandr
2015-10-23
Deinococcus radiodurans can survive extreme doses of ionizing radiation due to the very efficient DNA repair mechanisms that are able to cope even with hundreds of double-strand breaks. RecA, the critical protein of homologous recombination in bacteria, is one of the key components of the DNA-repair system. Repair of double-strand breaks requires RecA binding to DNA and assembly of the RecA nucleoprotein helical filaments. The Escherichia coli RecA protein (EcRecA) and its interactions with DNA have been extensively studied using various approaches including single-molecule techniques, while the D. radiodurans RecA (DrRecA) remains much less characterized. However, DrRecA shows some remarkable differencesmore » from E. coli homolog. Here we combine microfluidics and single-molecule DNA manipulation with optical tweezers to follow the binding of DrRecA to long double-stranded DNA molecules and probe the mechanical properties of DrRecA nucleoprotein filaments at physiological pH. Our data provide a direct comparison of DrRecA and EcRecA binding to double-stranded DNA under identical conditions. We report a significantly faster filaments assembly as well as lower values of persistence length and contour length for DrRecA nucleoprotein filaments compared to EcRecA. Our results support the existing model of DrRecA forming more frequent and less continuous filaments relative to those of EcRecA. - Highlights: • We investigate Deinococcus radiodurans RecA interactions with long double-stranded DNA at the single-molecule level. • At physiological pH D. radiodurans RecA forms nucleoprotein filaments significantly faster relative to Escherichia coli RecA. • D. radiodurans RecA-dsDNA nucleoprotein filaments are more flexible and slightly shorter compared to those of E. coli RecA.« less
Anaerobic capacity of the upper arms in top-level team handball players.
Kounalakis, Stylianos N; Bayios, Ioannis A; Koskolou, Maria D; Geladas, Nickos D
2008-09-01
Handball is a sport with high anaerobic demands in lower body as has been indicated by Wingate test (WT) performed with the legs, but there are no data available concerning power production during a WT performed with the arms in handball players (HndP). Therefore, the purpose of this study was to explore the arm anaerobic profile of HndP during a WT. Twenty-one elite HndP and 9 physical education students (CON), performed a 30-s arm WT. Power production and muscle oxygenation were recorded. Peak power (PP) as well as mean power (MP) was higher (P = .017 and 0.03, and ES = 1.00 and 0.86, respectively) for HndP (HndP PP: 7.6 +/- 0.8 W x kg(-1); CON PP: 6.7 +/- 1.1 W x kg(-1); HndP MP 5.3 +/- 0.6 W x kg(-1); CON MP 4.7 +/- 0.9 W x kg(-1)) with no significant difference in fatigue index between the two groups. Muscle oxygen saturation (StO2) declined approximately 30% with exercise with no differences between groups. During recovery the HndP group had higher StO2 (P = .01, ES= 3.04), total hemoglobin and oxygenated hemoglobin compared with the CON group (P < .01 ES = 3.29 and 0.99, respectively). StO2 returned to resting values in 29.5 +/- 2.3 s in HndP, whereas this variable did not recover after 2 min in CON. The arm anaerobic capacity of the HndP was "excellent," significantly higher than that by the control group. Moreover, HndP exhibited faster recovery of StO2 compared with the control group. The greater power output and the faster muscle reoxygenation of arms in HndP can be attributed to specific training adaptations related to high performance in handball.
A fast and robust iterative algorithm for prediction of RNA pseudoknotted secondary structures
2014-01-01
Background Improving accuracy and efficiency of computational methods that predict pseudoknotted RNA secondary structures is an ongoing challenge. Existing methods based on free energy minimization tend to be very slow and are limited in the types of pseudoknots that they can predict. Incorporating known structural information can improve prediction accuracy; however, there are not many methods for prediction of pseudoknotted structures that can incorporate structural information as input. There is even less understanding of the relative robustness of these methods with respect to partial information. Results We present a new method, Iterative HFold, for pseudoknotted RNA secondary structure prediction. Iterative HFold takes as input a pseudoknot-free structure, and produces a possibly pseudoknotted structure whose energy is at least as low as that of any (density-2) pseudoknotted structure containing the input structure. Iterative HFold leverages strengths of earlier methods, namely the fast running time of HFold, a method that is based on the hierarchical folding hypothesis, and the energy parameters of HotKnots V2.0. Our experimental evaluation on a large data set shows that Iterative HFold is robust with respect to partial information, with average accuracy on pseudoknotted structures steadily increasing from roughly 54% to 79% as the user provides up to 40% of the input structure. Iterative HFold is much faster than HotKnots V2.0, while having comparable accuracy. Iterative HFold also has significantly better accuracy than IPknot on our HK-PK and IP-pk168 data sets. Conclusions Iterative HFold is a robust method for prediction of pseudoknotted RNA secondary structures, whose accuracy with more than 5% information about true pseudoknot-free structures is better than that of IPknot, and with about 35% information about true pseudoknot-free structures compares well with that of HotKnots V2.0 while being significantly faster. Iterative HFold and all data used in this work are freely available at http://www.cs.ubc.ca/~hjabbari/software.php. PMID:24884954
Witjas-Paalberends, E Rosalie; Ferrara, Claudia; Scellini, Beatrice; Piroddi, Nicoletta; Montag, Judith; Tesi, Chiara; Stienen, Ger J M; Michels, Michelle; Ho, Carolyn Y; Kraft, Theresia; Poggesi, Corrado; van der Velden, Jolanda
2014-08-01
The first mutation associated with hypertrophic cardiomyopathy (HCM) is the R403Q mutation in the gene encoding β-myosin heavy chain (β-MyHC). R403Q locates in the globular head of myosin (S1), responsible for interaction with actin, and thus motor function of myosin. Increased cross-bridge relaxation kinetics caused by the R403Q mutation might underlie increased energetic cost of tension generation; however, direct evidence is absent. Here we studied to what extent cross-bridge kinetics and energetics are related in single cardiac myofibrils and multicellular cardiac muscle strips of three HCM patients with the R403Q mutation and nine sarcomere mutation-negative HCM patients (HCMsmn). Expression of R403Q was on average 41 ± 4% of total MYH7 mRNA. Cross-bridge slow relaxation kinetics in single R403Q myofibrils was significantly higher (P < 0.0001) than in HCMsmn myofibrils (0.47 ± 0.02 and 0.30 ± 0.02 s(-1), respectively). Moreover, compared to HCMsmn, tension cost was significantly higher in the muscle strips of the three R403Q patients (2.93 ± 0.25 and 1.78 ± 0.10 μmol l(-1) s(-1) kN(-1) m(-2), respectively) which showed a positive linear correlation with relaxation kinetics in the corresponding myofibril preparations. This correlation suggests that faster cross-bridge relaxation kinetics results in an increase in energetic cost of tension generation in human HCM with the R403Q mutation compared to HCMsmn. Therefore, increased tension cost might contribute to HCM disease in patients carrying the R403Q mutation. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.
Large-scale seismic waveform quality metric calculation using Hadoop
NASA Astrophysics Data System (ADS)
Magana-Zook, S.; Gaylord, J. M.; Knapp, D. R.; Dodge, D. A.; Ruppert, S. D.
2016-09-01
In this work we investigated the suitability of Hadoop MapReduce and Apache Spark for large-scale computation of seismic waveform quality metrics by comparing their performance with that of a traditional distributed implementation. The Incorporated Research Institutions for Seismology (IRIS) Data Management Center (DMC) provided 43 terabytes of broadband waveform data of which 5.1 TB of data were processed with the traditional architecture, and the full 43 TB were processed using MapReduce and Spark. Maximum performance of 0.56 terabytes per hour was achieved using all 5 nodes of the traditional implementation. We noted that I/O dominated processing, and that I/O performance was deteriorating with the addition of the 5th node. Data collected from this experiment provided the baseline against which the Hadoop results were compared. Next, we processed the full 43 TB dataset using both MapReduce and Apache Spark on our 18-node Hadoop cluster. These experiments were conducted multiple times with various subsets of the data so that we could build models to predict performance as a function of dataset size. We found that both MapReduce and Spark significantly outperformed the traditional reference implementation. At a dataset size of 5.1 terabytes, both Spark and MapReduce were about 15 times faster than the reference implementation. Furthermore, our performance models predict that for a dataset of 350 terabytes, Spark running on a 100-node cluster would be about 265 times faster than the reference implementation. We do not expect that the reference implementation deployed on a 100-node cluster would perform significantly better than on the 5-node cluster because the I/O performance cannot be made to scale. Finally, we note that although Big Data technologies clearly provide a way to process seismic waveform datasets in a high-performance and scalable manner, the technology is still rapidly changing, requires a high degree of investment in personnel, and will likely require significant changes in other parts of our infrastructure. Nevertheless, we anticipate that as the technology matures and third-party tool vendors make it easier to manage and operate clusters, Hadoop (or a successor) will play a large role in our seismic data processing.
Evaluation of Techniques for Measuring Microbial Hazards in Bathing Waters: A Comparative Study
Schang, Christelle; Henry, Rebekah; Kolotelo, Peter A.; Prosser, Toby; Crosbie, Nick; Grant, Trish; Cottam, Darren; O’Brien, Peter; Coutts, Scott; Deletic, Ana; McCarthy, David T.
2016-01-01
Recreational water quality is commonly monitored by means of culture based faecal indicator organism (FIOs) assays. However, these methods are costly and time-consuming; a serious disadvantage when combined with issues such as non-specificity and user bias. New culture and molecular methods have been developed to counter these drawbacks. This study compared industry-standard IDEXX methods (Colilert and Enterolert) with three alternative approaches: 1) TECTA™ system for E. coli and enterococci; 2) US EPA’s 1611 method (qPCR based enterococci enumeration); and 3) Next Generation Sequencing (NGS). Water samples (233) were collected from riverine, estuarine and marine environments over the 2014–2015 summer period and analysed by the four methods. The results demonstrated that E. coli and coliform densities, inferred by the IDEXX system, correlated strongly with the TECTA™ system. The TECTA™ system had further advantages in faster turnaround times (~12 hrs from sample receipt to result compared to 24 hrs); no staff time required for interpretation and less user bias (results are automatically calculated, compared to subjective colorimetric decisions). The US EPA Method 1611 qPCR method also showed significant correlation with the IDEXX enterococci method; but had significant disadvantages such as highly technical analysis and higher operational costs (330% of IDEXX). The NGS method demonstrated statistically significant correlations between IDEXX and the proportions of sequences belonging to FIOs, Enterobacteriaceae, and Enterococcaceae. While costs (3,000% of IDEXX) and analysis time (300% of IDEXX) were found to be significant drawbacks of NGS, rapid technological advances in this field will soon see it widely adopted. PMID:27213772
Two-ply channels for faster wicking in paper-based microfluidic devices.
Camplisson, Conor K; Schilling, Kevin M; Pedrotti, William L; Stone, Howard A; Martinez, Andres W
2015-12-07
This article describes the development of porous two-ply channels for paper-based microfluidic devices that wick fluids significantly faster than conventional, porous, single-ply channels. The two-ply channels were made by stacking two single-ply channels on top of each other and were fabricated entirely out of paper, wax and toner using two commercially available printers, a convection oven and a thermal laminator. The wicking in paper-based channels was studied and modeled using a modified Lucas-Washburn equation to account for the effect of evaporation, and a paper-based titration device incorporating two-ply channels was demonstrated.
Prior topical anesthesia reduces time to full cycloplegia in Chinese.
Siu, A W; Sum, A C; Lee, D T; Tam, K W; Chan, S W
1999-01-01
To investigate the effect of prior anesthesia on the time to full cycloplegia in young Chinese subjects. The amplitude of accommodation was monitored over a 50-minute interval after the application of 1% cyclopentolate hydrochloride with a pretreatment of 0.4% benoxinate (oxybuprocaine) or 0.9% saline solution (control). Using a nonlinear mathematical model, the rate of accommodative loss (k) and the time required for 95% of total cycloplegia (T95%) were determined. Statistical analysis revealed a significantly faster rate of accommodative loss (P < .0001) after prior anesthesia (0.129 +/- 0.05) compared with the controls (0.103 +/- 0.04). T95% was noted at 26.43 +/- 10.22 minutes after prior anesthesia, which was significantly shorter (P < .0001) than that after the saline treatment (35.28 +/- 16.51 minutes). Prior application of topical anesthetic can shorten the time to full cycloplegia for people, such as the Chinese, with dark irides.
Effects of sevoflurane anaesthesia on recovery in children: a comparison with halothane.
Lapin, S L; Auden, S M; Goldsmith, L J; Reynolds, A M
1999-01-01
We prospectively studied one hundred ASA physical status I-II children, ages six months to six years, undergoing myringotomy surgery. Children were randomly assigned to one of four anaesthetic groups receiving either halothane or sevoflurane for anaesthesia and oral midazolam premedication or no premedication. We found that children anaesthetized with sevoflurane had significantly faster recovery times and discharge home times than those who received halothane. Patients given oral midazolam premedication had significantly longer recovery times, but no delay in discharge home compared with those not premedicated. However, children anaesthetized with sevoflurane and no premedication had an unacceptably high incidence (67%) of postoperative agitation. The use of oral midazolam preoperatively did decrease the amount of postoperative agitation seen with sevoflurane. We conclude that although sevoflurane does shorten recovery times, the degree of associated postoperative agitation makes it unacceptable as a sole anaesthetic for myringotomy surgery.
Balance training reduces falls risk in older individuals with type 2 diabetes.
Morrison, Steven; Colberg, Sheri R; Mariano, Mira; Parson, Henri K; Vinik, Arthur I
2010-04-01
This study assessed the effects of balance/strength training on falls risk and posture in older individuals with type 2 diabetes. Sixteen individuals with type 2 diabetes and 21 age-matched control subjects (aged 50-75 years) participated. Postural stability and falls risk was assessed before and after a 6-week exercise program. Diabetic individuals had significantly higher falls risk score compared with control subjects. The diabetic group also exhibited evidence of mild-to-moderate neuropathy, slower reaction times, and increased postural sway. Following exercise, the diabetic group showed significant improvements in leg strength, faster reaction times, decreased sway, and, consequently, reduced falls risk. Older individuals with diabetes had impaired balance, slower reactions, and consequently a higher falls risk than age-matched control subjects. However, all these variables improved after resistance/balance training. Together these results demonstrate that structured exercise has wide-spread positive effects on physiological function for older individuals with type 2 diabetes.
Yamagishi, Hatsushi; Koike, Tomoyuki; Ohara, Shuichi; Horii, Toru; Kikuchi, Ryousuke; Kobayashi, Shigeyuki; Abe, Yasuhiko; Iijima, Katsunori; Imatani, Akira; Suzuki, Kaori; Hishinuma, Takanori; Goto, Junichi; Shimosegawa, Tooru
2008-01-01
AIM: To compare rabeprazole (RPZ; 10 mg) with Lansoprazole orally disintegrating tablets (LPZ; 30 mg OD) in terms of antisecretory activity and blood drug concentration after a single dose. METHODS: Eight H pylori-negative cytochrome P450 (CYP) 2C19 extensive metabolizers were assigned to receive a single oral dose of RPZ 10 mg or LPZ 30 mg OD. Twelve hour intragastric pH monitoring was performed on the day of treatment. Blood samples were also collected after the administration of each drug. RESULTS: LPZ 30 mg OD induced a significantly earlier rise in blood drug concentration than RPZ 10 mg; consequently, LPZ 30 mg OD induced a significantly earlier rise in median pH in the third and fourth hours of the study. CONCLUSION: In H pylori-negative CYP2C19 extensive metabolizers, LPZ 30 mg OD induced a significantly faster inhibition of gastric acid secretion than RPZ 10 mg. PMID:18395905
Alexander, Michael B; Hodges, Theresa K; Wescott, Daniel J; Aitkenhead-Peterson, Jacqueline A
2016-05-01
Despite technological advances, human remains detection (HRD) dogs still remain one of the best tools for locating clandestine graves. However, soil texture may affect the escape of decomposition gases and therefore the effectiveness of HDR dogs. Six nationally credentialed HRD dogs (three HRD only and three cross-trained) were evaluated on novel buried human remains in contrasting soils, a clayey and a sandy soil. Search time and accuracy were compared for the clayey soil and sandy soil to assess odor location difficulty. Sandy soil (p < 0.001) yielded significantly faster trained response times, but no significant differences were found in performance accuracy between soil textures or training method. Results indicate soil texture may be significant factor in odor detection difficulty. Prior knowledge of soil texture and moisture may be useful for search management and planning. Appropriate adjustments to search segment sizes, sweep widths and search time allotment depending on soil texture may optimize successful detection. © 2016 American Academy of Forensic Sciences.
NASA Technical Reports Server (NTRS)
Pierotti, David J.; Roy, Roland R.; Flores, Vinicio; Edgerton, Reggie
1990-01-01
The effect of intermittent periods of weight support on a decrease in mass of the soleus (Sol) and medial gastrocnemius (MG) muscles atrophied by hindlimb suspension (HS) was investigated in rats subjected to continuous HS for seven days or an HS plus intermittent (10 min every 6 hrs of slow walking on a treadmill) weight support (HS-WS). After 7 d HS, the Sol weight relative to body weight was 21 and 9 percent lower in Hs and HS-WS, respectively, than in control rats. Maximum tetanic tension/muscle mass ratio was significantly lower in HS than in controls; the HS-WS rats had values similar to controls, whereas the maximum tetanic tension/muscle weight was significantly elevated in HS-WS compared to controls. Contraction times were 25 percent faster in the Sol and unchanged in the MG of HS rats, indicating that a low-force short-duration exercise regime results in a significant functional recovery in the 'slow' Sol, whereas the 'fast' MG is less affected.
The role and importance of porosity in the deflagration rates of HMX-based materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glascoe, E A; Hsu, P C; Springer, H K
The deflagration behavior of thermally damaged HMX-based materials will be discussed. Strands of material were burned at pressures ranging from 10-300 MPa using the LLNL high pressure strand burner. Strands were heated in-situ and burned while still hot; temperatures range from 90-200 C and were chosen in order to allow for thermal damage of the material without significant decomposition of the HMX. The results indicate that multiple variables affect the burn rate but the most important are the polymorph of HMX and the nature and thermal stability of the non-HE portion of the material. Characterization of the strands indicate thatmore » the thermal soak produces significant porosity and permeability in the sample allowing for significantly faster burning due to the increased surface area and new pathways for flame spread into the material. Specifically, the deflagration rates of heated PBXN-9, LX-10, and PBX-9501 will be discussed and compared.« less
Li, Meng; Zhang, Lu; Davé, Rajesh N; Bilgili, Ecevit
2016-04-01
As a drug-sparing approach in early development, vibratory milling has been used for the preparation of nanosuspensions of poorly water-soluble drugs. The aim of this study was to intensify this process through a systematic increase in vibration intensity and bead loading with the optimal bead size for faster production. Griseofulvin, a poorly water-soluble drug, was wet-milled using yttrium-stabilized zirconia beads with sizes ranging from 50 to 1500 μm at low power density (0.87 W/g). Then, this process was intensified with the optimal bead size by sequentially increasing vibration intensity and bead loading. Additional experiments with several bead sizes were performed at high power density (16 W/g), and the results were compared to those from wet stirred media milling. Laser diffraction, scanning electron microscopy, X-ray diffraction, differential scanning calorimetry, and dissolution tests were used for characterization. Results for the low power density indicated 800 μm as the optimal bead size which led to a median size of 545 nm with more than 10% of the drug particles greater than 1.8 μm albeit the fastest breakage. An increase in either vibration intensity or bead loading resulted in faster breakage. The most intensified process led to 90% of the particles being smaller than 300 nm. At the high power intensity, 400 μm beads were optimal, which enhanced griseofulvin dissolution significantly and signified the importance of bead size in view of the power density. Only the optimally intensified vibratory milling led to a comparable nanosuspension to that prepared by the stirred media milling.
Laveda, Josefa Vidal; Johnston, Beth; Paterson, Gary W.; ...
2017-12-04
Microwave heating presents a faster, lower energy synthetic methodology for the realization of functional materials. Here, we demonstrate for the first time that employing this method also leads to a decrease in the occurrence of defects in olivine structured LiFe 1–xMn xPO 4. For example, the presence of antisite defects in this structure precludes Li + diffusion along the b-axis leading to a significant decrease in reversible capacities. Total scattering measurements, in combination with Li + diffusion studies using muon spin relaxation (μ+SR) spectroscopy, reveal that this synthetic method generates fewer defects in the nanostructures compared to traditional solvothermal routes.more » Our interest in developing these routes to mixed-metal phosphate LiFe 1–xMn xPO 4 olivines is due to the higher Mn 2+/ 3+ redox potential in comparison to the Fe 2+/ 3+ pair. Here, single-phase LiFe 1–xMn xPO 4 (x = 0, 0.25, 0.5, 0.75 and 1) olivines have been prepared following a microwave-assisted approach which allows for up to 4 times faster reaction times compared to traditional solvothermal methods. Interestingly, the resulting particle morphology is dependent on the Mn content. We also examine their electrochemical performance as active electrodes in Li-ion batteries. In conclusion, these results present microwave routes as highly attractive for reproducible, gram-scale syntheses of high quality nanostructured electrodes which display close to theoretical capacity for the full iron phase.« less
Zhou, Yipeng; Tian, Yunfan; Zhong, Chongke; Batu, Buren; Xu, Tian; Li, Hongmei; Zhang, Mingzhi; Wang, Aili; Zhang, Yonghong
2016-05-01
This study aimed to evaluate the combined effects of family history of cardiovascular diseases (FHCVD) and heart rate on ischemic stroke incidence among Inner Mongolians in China. A prospective cohort study was conducted among 2589 participants aged 20 years and older from Inner Mongolia, China. The participants were divided into four groups according to status of FHCVD and heart rate and followed up from June 2002 to July 2012. Cox proportional hazards models were used to evaluate the combined effects of FHCVD and heart rate on the incidence of ischemic stroke. A total of 76 ischemic stroke occurred during the follow-up period. The observed ischemic stroke cases tended to be older and male, and had higher prevalence of smoking, drinking, hypertension and FHCVD as well as higher systolic and diastolic blood pressures at baseline compared with those who did not experience ischemic stroke. Age- and gender-adjusted hazard ratio (95% confidence interval) of ischemic stroke in the participants with both FHCVD and heart rate ≥ 80 were 2.89 (1.51-5.53), compared with those without FHCVD and heart rate < 80. After multiple adjustment, the association between ischemic stroke risk and both FHCVD and heart rate ≥ 80 remained statistically significant (hazard ratio, 2.47; 95% confidence interval: 1.22-5.01). Our main finding that participants with both FHCVD and faster heart rate have the highest risk of ischemic stroke suggests that faster heart rate may increase the risk of ischemic stroke among people with FHCVD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laveda, Josefa Vidal; Johnston, Beth; Paterson, Gary W.
Microwave heating presents a faster, lower energy synthetic methodology for the realization of functional materials. Here, we demonstrate for the first time that employing this method also leads to a decrease in the occurrence of defects in olivine structured LiFe 1–xMn xPO 4. For example, the presence of antisite defects in this structure precludes Li + diffusion along the b-axis leading to a significant decrease in reversible capacities. Total scattering measurements, in combination with Li + diffusion studies using muon spin relaxation (μ+SR) spectroscopy, reveal that this synthetic method generates fewer defects in the nanostructures compared to traditional solvothermal routes.more » Our interest in developing these routes to mixed-metal phosphate LiFe 1–xMn xPO 4 olivines is due to the higher Mn 2+/ 3+ redox potential in comparison to the Fe 2+/ 3+ pair. Here, single-phase LiFe 1–xMn xPO 4 (x = 0, 0.25, 0.5, 0.75 and 1) olivines have been prepared following a microwave-assisted approach which allows for up to 4 times faster reaction times compared to traditional solvothermal methods. Interestingly, the resulting particle morphology is dependent on the Mn content. We also examine their electrochemical performance as active electrodes in Li-ion batteries. In conclusion, these results present microwave routes as highly attractive for reproducible, gram-scale syntheses of high quality nanostructured electrodes which display close to theoretical capacity for the full iron phase.« less
Föcker, Julia; Best, Anna; Hölig, Cordula; Röder, Brigitte
2012-07-01
Blind people rely much more on voices compared to sighted individuals when identifying other people. Previous research has suggested a faster processing of auditory input in blind individuals than sighted controls and an enhanced activation of temporal cortical regions during voice processing. The present study used event-related potentials (ERPs) to single out the sub-processes of auditory person identification that change and allow for superior voice processing after congenital blindness. A priming paradigm was employed in which two successive voices (S1 and S2) of either the same (50% of the trials) or different actors were presented. Congenitally blind and matched sighted participants made an old-young decision on the S2. During the pre-experimental familiarization with the stimuli, congenitally blind individuals showed faster learning rates than sighted controls. Reaction times were shorter in person-congruent trials than in person-incongruent trials in both groups. ERPs to S2 stimuli in person-incongruent as compared to person-congruent trials were significantly enhanced at early processing stages (100-160 ms) in congenitally blind participants only. A later negative ERP effect (>200 ms) was found in both groups. The scalp topographies of the experimental effects were characterized by a central and parietal distribution in the sighted but a more posterior distribution in the congenitally blind. These results provide evidence for an improvement of early voice processing stages and a reorganization of the person identification system as a neural correlate of compensatory behavioral improvements following congenital blindness. Copyright © 2012 Elsevier Ltd. All rights reserved.
Szarpak, Lukasz; Truszewski, Zenon; Smereka, Jacek; Krajewski, Paweł; Fudalej, Marcin; Adamczyk, Piotr; Czyzewski, Lukasz
2016-05-01
Medical personnel may encounter difficulties in obtaining intravenous (IV) access during cardiac arrest. The 2015 American Heart Association guidelines and the 2015 European Resuscitation Council guidelines for cardiopulmonary resuscitation (CPR) suggest that rescuers establish intraosseous (IO) access if an IV line is not easily obtainable.The aim of the study was to compare the success rates of the IO proximal tibia and proximal humerus head access performed by paramedics using the New Intraosseous access device (NIO; Persys Medical, Houston, TX, USA) in an adult cadaver model during simulated CPR.In an interventional, randomized, crossover, single-center cadaver study, a semi-automatic spring-load driven NIO access device was investigated. In total, 84 paramedics with less than 5-year experience in Emergency Medical Service participated in the study. The trial was performed on 42 adult cadavers. In each cadaver, 2 IO accesses to the humerus head, and 2 IO accesses to the proximal tibia were obtained.The success rate of the first IO attempt was 89.3% (75/84) for tibial access, and 73.8% (62/84) for humeral access (P = 0.017). The procedure times were significantly faster for tibial access [16.8 (interquartile range, IQR, 15.1-19.9] s] than humeral access [26.7 (IQR, 22.1-30.9) s] (P < 0.001).Tibial IO access is easier and faster to put in place than humeral IO access. Humeral IO access can be an alternative method to tibial IO access. clinicaltrials.gov Identifier: NCT02700867.
For blacks in America, the gap in neighborhood poverty has declined faster than segregation
Acciai, Francesco
2016-01-01
Black residential segregation has been declining in the United States. That accomplishment rings hollow, however, if blacks continue to live in much poorer neighborhoods than other Americans. This study uses census data for all US metropolitan areas in 1980 and 2010 to compare decline in the neighborhood poverty gap between blacks and other Americans with decline in the residential segregation of blacks. We find that both declines resulted primarily from narrowing differences between blacks and whites as opposed to narrowing differences between blacks and Hispanics or blacks and Asians. Because black–white differences in neighborhood poverty declined much faster than black–white segregation, the neighborhood poverty disadvantage of blacks declined faster than black segregation—a noteworthy finding because the narrowing of the racial gap in neighborhood poverty for blacks has gone largely unnoticed. Further analysis reveals that the narrowing of the gap was produced by change in both the medians and shapes of the distribution of poverty across the neighborhoods where blacks, whites, Hispanics, and Asians reside. PMID:27821759
For blacks in America, the gap in neighborhood poverty has declined faster than segregation.
Firebaugh, Glenn; Acciai, Francesco
2016-11-22
Black residential segregation has been declining in the United States. That accomplishment rings hollow, however, if blacks continue to live in much poorer neighborhoods than other Americans. This study uses census data for all US metropolitan areas in 1980 and 2010 to compare decline in the neighborhood poverty gap between blacks and other Americans with decline in the residential segregation of blacks. We find that both declines resulted primarily from narrowing differences between blacks and whites as opposed to narrowing differences between blacks and Hispanics or blacks and Asians. Because black-white differences in neighborhood poverty declined much faster than black-white segregation, the neighborhood poverty disadvantage of blacks declined faster than black segregation-a noteworthy finding because the narrowing of the racial gap in neighborhood poverty for blacks has gone largely unnoticed. Further analysis reveals that the narrowing of the gap was produced by change in both the medians and shapes of the distribution of poverty across the neighborhoods where blacks, whites, Hispanics, and Asians reside.
Arthroscopic excision of ganglion cysts.
Bontempo, Nicholas A; Weiss, Arnold-Peter C
2014-02-01
Arthroscopy is an advancing field in orthopedics, the applications of which have been expanding over time. Traditionally, excision of ganglion cysts has been done in an open fashion. However, more recently, studies show outcomes following arthroscopic excision to be as good as open excision. Cosmetically, the incisions are smaller and heal faster following arthroscopy. In addition, there is the suggested benefit that patients will regain function and return to work faster following arthroscopic excision. More prospective studies comparing open and arthroscopic excision of ganglion cysts need to be done in order to delineate if there is a true functional benefit. Copyright © 2014 Elsevier Inc. All rights reserved.
Efficient solution of the simplified P N equations
Hamilton, Steven P.; Evans, Thomas M.
2014-12-23
We show new solver strategies for the multigroup SPN equations for nuclear reactor analysis. By forming the complete matrix over space, moments, and energy a robust set of solution strategies may be applied. Moreover, power iteration, shifted power iteration, Rayleigh quotient iteration, Arnoldi's method, and a generalized Davidson method, each using algebraic and physics-based multigrid preconditioners, have been compared on C5G7 MOX test problem as well as an operational PWR model. These results show that the most ecient approach is the generalized Davidson method, that is 30-40 times faster than traditional power iteration and 6-10 times faster than Arnoldi's method.
Software-assisted small bowel motility analysis using free-breathing MRI: feasibility study.
Bickelhaupt, Sebastian; Froehlich, Johannes M; Cattin, Roger; Raible, Stephan; Bouquet, Hanspeter; Bill, Urs; Patak, Michael A
2014-01-01
To validate a software prototype allowing for small bowel motility analysis in free breathing by comparing it to manual measurements. In all, 25 patients (15 male, 10 female; mean age 39 years) were included in this Institutional Review Board-approved, retrospective study. Magnetic resonance imaging (MRI) was performed on a 1.5T system after standardized preparation acquiring motility sequences in free breathing over 69-84 seconds. Small bowel motility was analyzed manually and with the software. Functional parameters, measurement time, and reproducibility were compared using the coefficient of variance and paired Student's t-test. Correlation was analyzed using Pearson's correlation coefficient and linear regression. The 25 segments were analyzed twice both by hand and using the software with automatic breathing correction. All assessed parameters significantly correlated between the methods (P < 0.01), but the scattering of repeated measurements was significantly (P < 0.01) lower using the software (3.90%, standard deviation [SD] ± 5.69) than manual examinations (9.77%, SD ± 11.08). The time needed was significantly less (P < 0.001) with the software (4.52 minutes, SD ± 1.58) compared to manual measurement, lasting 17.48 minutes for manual (SD ± 1.75 minutes). The use of the software proves reliable and faster small bowel motility measurements in free-breathing MRI compared to manual analyses. The new technique allows for analyses of prolonged sequences acquired in free breathing, improving the informative value of the examinations by amplifying the evaluable data. Copyright © 2013 Wiley Periodicals, Inc.
Quantitative assessment of drawing tests in children with dyslexia and dysgraphia.
Galli, Manuela; Cimolin, Veronica; Stella, Giacomo; De Pandis, Maria Francesca; Ancillao, Andrea; Condoluci, Claudia
2018-05-07
Drawing tests in children diagnosed with dyslexia and dysgraphia were quantitatively compared. Fourteen children with dysgraphia, 19 with dyslexia and 13 normally developing were asked to copy 3 figures: a circle, a square and a cross. An optoelectronic system allowed the acquisition of the drawing track in three-dimensions. The participants' head position and upper limb movements were measured as well. A set of parameters including movement duration, velocity, length of the trace, Range of Motion of the upper limb, was computed and compared among the 3 groups. Children with dyslexia traced the circle faster than the other groups. In the cross test, dyslexic participants showed a reduced execution time and increased velocity while drawing the horizontal line. Children with dyslexia were also faster in drawing certain sides of square with respect to the other groups. Copyright © 2018 Elsevier B.V. All rights reserved.
Gilligan, Adrienne M.; Waycaster, Curtis R.; Bizier, Richard; Chu, Bong-Chul; Carter, Marissa J.; Fife, Caroline E.
2017-01-01
Objective: Compare enzymatic debridement using clostridial collagenase ointment (CCO) with autolytic debridement using medicinal honey in the hospital outpatient setting for treating pressure ulcers (PUs). Approach: Retrospective deidentified electronic health records from 2007–2013 were extracted from the U.S. Wound Registry. Propensity score matching followed by multivariable analyses was used to adjust for selection bias and assess treatment effects comparing CCO-treated versus honey-treated PUs. Key outcomes included 100% granulation and epithelialization at 1 year. Results: Five hundred seventeen CCO-treated PUs (446 patients) were matched to corresponding honey-treated PUs (341 patients). The majority of PUs were stage III (CCO 56%, honey 55%). CCO users had significantly fewer total visits (9.1 vs. 12.6; p < 0.001), fewer total selective sharp debridements (2.7 vs. 4.4; p < 0.001), and fewer PUs receiving negative pressure wound therapy (29% vs. 38%; p = 0.002) compared with honey. Innovation: CCO-treated PUs were 38% more likely to achieve 100% granulation compared to honey-treated PUs at 1 year, p = 0.018. Mean days to 100% granulation were significantly lower for CCO-treated PUs (255 vs. 282 days, p < 0.001). CCO-treated PUs were 47% (p = 0.024) more likely to epithelialize at 1 year compared to PUs treated with honey. Mean days to epithelialization were significantly lower for PUs treated with CCO at 1 year (288 vs. 308 days; p = 0.011). Conclusion: All stages of PUs treated with CCO achieved faster rates of granulation and subsequent epithelialization compared to PUs treated with medicinal honey as measured by real-world data collected in the hospital outpatient department care setting. PMID:28451469
Shan, Siqing; Flowers, Clay; Peltz, Cathy D; Sweet, Heather; Maurer, Norbert; Kwon, Eun-Joo Gina; Krol, Ave; Yuan, Fan; Dewhirst, Mark W
2006-08-01
To quantitatively evaluate the extravasation, accumulation and selectivity to tumor tissues of liposomal vincristine (LV), dorsal skin-fold window chambers on athymic mice with or without LX-1, a human small cell lung cancer, xenograft implants and fluorescent intravital microscopy imaging were used. In vitro studies show that minimal loss of fluorescence marker DiI from liposomes occurs after 4 days of inoculation in murine plasma, and the release profiles of DiI-LV and LV were essentially the same with approximately 40% of the encapsulated vincristine sulfate (VCR) released after 26 h. Significantly faster extravasation of DiI-LV from tumor vessels was shown compared to non-tumor tissue after single dose i.v. administration. The relative interstitial amounts at 60 min (RIA(60)) for tumor and non-tumor tissues were 0.837+/-0.314 and 0.012+/-0.091, respectively (P=0.01). DiI-LV accumulation was significantly higher in tumor than in normal tissue, which continued beyond 48 h. Both DiI-LV and LV showed significant antitumor effects in window chambers and in flank tumors, compared with controls and VLS alone. The preferential extravasation of DiI-LV from tumor vasculature as well as its differential retention in tumor tissue provides the basis for the enhancement in antitumor activity of LV over VCR.
Canal Aberration Assessment in Simulated Root Canals: a Comparative Study
Jakupovic, Selma; Konjhodzic, Alma; Brankovic, Lajla Hasic; Korac, Samra; Tahmiscija, Irmina; Dzankovic, Aida; Glamoc, Alma Gavranovic
2017-01-01
Aim: The aim of this study was to compare time of preparation and canal aberrations in a simulated root canals after using three different rotary systems: Endostar E5, Endostar E3 and T One File Gold. Materials and Methods: A total of 90 endodontic training blocks were used in this study and divided into three groups consisting of 30 each (n = 30). Blocks processing was performed by thirty dentists without any prior experience in rotary instrumentation techniques. In the first group blocks were prepared using Endostar E5, in second one with Endostar E3 and in third one with T One File Gold system. The preparation time was measured. The postoperative image of each block was taken by stereomicroscope and canal aberrations (ledge and instrument fracture) was recorded. Statistical analysis was done by SPSS software. Results: Instrumentation with T One File Gold system is significantly faster compared to instrumentation with Endostar E5 and Endostar E3 systems (p <0.05). There are no statistically significant differences in the type and number of procedural errors between Endostar E5, Endostar E3 and T One File Gold systems when the operators have no previous experience in rotary instrumentation techniques. Conclusion: Under the conditions of this study, the incidence of examined canal aberrations were similar for all tested systems. The preparation time was significantly shorter with single file system. PMID:28974834
Schoenthaler, Martin; Avcil, Tuba; Sevcenco, Sabina; Nagele, Udo; Hermann, Thomas E W; Kuehhas, Franklin E; Shariat, Shahrokh F; Frankenschmidt, Alexander; Wetterauer, Ulrich; Miernik, Arkadiusz
2015-01-01
To evaluate the Single-Incision Transumbilical Surgery (SITUS) technique as compared to an established laparoendoscopic single-site surgery (LESS) technique (Single-Port Laparoscopic Surgery, SPLS) and conventional laparoscopy (CLS) in a surgical simulator model. Sixty-three medical students without previous laparoscopic experience were randomly assigned to one of the three groups (SITUS, SPLS and CLS). Subjects were asked to perform five standardized tasks of increasing difficulty adopted from the Fundamentals of Laparoscopic Surgery curriculum. Statistical evaluation included task completion times and accuracy. Overall performances of all tasks (except precision cutting) were significantly faster and of higher accuracy in the CLS and SITUS groups than in the SPLS group (p = 0.004 to p < 0.001). CLS and SITUS groups alone showed no significant difference in performance times and accuracy measurements for all tasks (p = 0.048 to p = 0.989). SITUS proved to be a simple, but highly effective technique to overcome restrictions of SPLS. In a surgical simulator model, novices were able to achieve task performances comparable to CLS and did significantly better than using a port-assisted LESS technique such as SPLS. The demonstrated advantages of SITUS may be attributed to a preservation of the basic principles of conventional laparoscopy, such as the use of straight instruments and an adequate degree of triangulation.
Ferrara, Giulia; Taschieri, Silvio; Corbella, Stefano; Ceci, Caterina; Del Fabbro, Massimo; Machtou, Pierre
2017-02-01
The aim of the present study was to compare the shaping ability of two different nickel-titanium rotary files in the curved root canals of extracted human molar teeth. Thirty root canals of 17 extracted human molars teeth were randomly assigned to two experimental groups (n = 15): ProTaper Next and ProTaper Universal (PTU), on the basis of the rotary files system used. The final size of all apical foramina was 0.25 mm in diameter. Standardized digital radiographs were taken before and after instrumentation in both clinical and proximal views, with a size 10 K-file inserted into the canal for the determination of the angle of curvature and apical transportation. Preparation time and fractured or deformed instruments were also recorded. The unpaired Student's t-test was used to compare results. There was no significant difference between the two instruments with respect to canal straightening and apical transportation before and after instrumentation (P > 0.05). The use of both instruments resulted in a significant reduction in the angle of curvature after instrumentation (P < 0.05). Instrumentation time was significantly greater for PTU (P < 0.05). The ProTaper Universal and ProTaper Next systems performed similarly with regard to the straightening of curved root canals and apical transportation. ProTaper Next was significantly faster than ProTaper Universal. © 2015 Wiley Publishing Asia Pty Ltd.