Sample records for simple accurate method

  1. Simple Test Functions in Meshless Local Petrov-Galerkin Methods

    NASA Technical Reports Server (NTRS)

    Raju, Ivatury S.

    2016-01-01

    Two meshless local Petrov-Galerkin (MLPG) methods based on two different trial functions but that use a simple linear test function were developed for beam and column problems. These methods used generalized moving least squares (GMLS) and radial basis (RB) interpolation functions as trial functions. These two methods were tested on various patch test problems. Both methods passed the patch tests successfully. Then the methods were applied to various beam vibration problems and problems involving Euler and Beck's columns. Both methods yielded accurate solutions for all problems studied. The simple linear test function offers considerable savings in computing efforts as the domain integrals involved in the weak form are avoided. The two methods based on this simple linear test function method produced accurate results for frequencies and buckling loads. Of the two methods studied, the method with radial basis trial functions is very attractive as the method is simple, accurate, and robust.

  2. A Simple yet Accurate Method for Students to Determine Asteroid Rotation Periods from Fragmented Light Curve Data

    ERIC Educational Resources Information Center

    Beare, R. A.

    2008-01-01

    Professional astronomers use specialized software not normally available to students to determine the rotation periods of asteroids from fragmented light curve data. This paper describes a simple yet accurate method based on Microsoft Excel[R] that enables students to find periods in asteroid light curve and other discontinuous time series data of…

  3. BASIC: A Simple and Accurate Modular DNA Assembly Method.

    PubMed

    Storch, Marko; Casini, Arturo; Mackrow, Ben; Ellis, Tom; Baldwin, Geoff S

    2017-01-01

    Biopart Assembly Standard for Idempotent Cloning (BASIC) is a simple, accurate, and robust DNA assembly method. The method is based on linker-mediated DNA assembly and provides highly accurate DNA assembly with 99 % correct assemblies for four parts and 90 % correct assemblies for seven parts [1]. The BASIC standard defines a single entry vector for all parts flanked by the same prefix and suffix sequences and its idempotent nature means that the assembled construct is returned in the same format. Once a part has been adapted into the BASIC format it can be placed at any position within a BASIC assembly without the need for reformatting. This allows laboratories to grow comprehensive and universal part libraries and to share them efficiently. The modularity within the BASIC framework is further extended by the possibility of encoding ribosomal binding sites (RBS) and peptide linker sequences directly on the linkers used for assembly. This makes BASIC a highly versatile library construction method for combinatorial part assembly including the construction of promoter, RBS, gene variant, and protein-tag libraries. In comparison with other DNA assembly standards and methods, BASIC offers a simple robust protocol; it relies on a single entry vector, provides for easy hierarchical assembly, and is highly accurate for up to seven parts per assembly round [2].

  4. A simple method for HPLC retention time prediction: linear calibration using two reference substances.

    PubMed

    Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng

    2017-01-01

    Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.

  5. A Simple and Accurate Method for Measuring Enzyme Activity.

    ERIC Educational Resources Information Center

    Yip, Din-Yan

    1997-01-01

    Presents methods commonly used for investigating enzyme activity using catalase and presents a new method for measuring catalase activity that is more reliable and accurate. Provides results that are readily reproduced and quantified. Can also be used for investigations of enzyme properties such as the effects of temperature, pH, inhibitors,…

  6. Simple and accurate method for determining dissolved inorganic carbon in environmental water by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2018-03-01

    We investigate a simple and accurate method for quantitatively analyzing dissolved inorganic carbon in environmental water by reaction headspace gas chromatography. The neutralization reaction between the inorganic carbon species (i.e. bicarbonate ions and carbonate ions) in environmental water and hydrochloric acid is carried out in a sealed headspace vial, and the carbon dioxide formed from the neutralization reaction, the self-decomposition of carbonic acid, and dissolved carbon dioxide in environmental water is then analyzed by headspace gas chromatography. The data show that the headspace gas chromatography method has good precision (relative standard deviation ≤ 1.63%) and accuracy (relative differences ≤ 5.81% compared with the coulometric titration technique). The headspace gas chromatography method is simple, reliable, and can be well applied in the dissolved inorganic carbon detection in environmental water. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Advantage of multiple spot urine collections for estimating daily sodium excretion: comparison with two 24-h urine collections as reference.

    PubMed

    Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi

    2016-02-01

    Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62  mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.

  8. Accurate Time/Frequency Transfer Method Using Bi-Directional WDM Transmission

    NASA Technical Reports Server (NTRS)

    Imaoka, Atsushi; Kihara, Masami

    1996-01-01

    An accurate time transfer method is proposed using b-directional wavelength division multiplexing (WDM) signal transmission along a single optical fiber. This method will be used in digital telecommunication networks and yield a time synchronization accuracy of better than 1 ns for long transmission lines over several tens of kilometers. The method can accurately measure the difference in delay between two wavelength signals caused by the chromatic dispersion of the fiber in conventional simple bi-directional dual-wavelength frequency transfer methods. We describe the characteristics of this difference in delay and then show that the accuracy of the delay measurements can be obtained below 0.1 ns by transmitting 156 Mb/s times reference signals of 1.31 micrometer and 1.55 micrometers along a 50 km fiber using the proposed method. The sub-nanosecond delay measurement using the simple bi-directional dual-wavelength transmission along a 100 km fiber with a wavelength spacing of 1 nm in the 1.55 micrometer range is also shown.

  9. A simple finite element method for the Stokes equations

    DOE PAGES

    Mu, Lin; Ye, Xiu

    2017-03-21

    The goal of this paper is to introduce a simple finite element method to solve the Stokes equations. This method is in primal velocity-pressure formulation and is so simple such that both velocity and pressure are approximated by piecewise constant functions. Implementation issues as well as error analysis are investigated. A basis for a divergence free subspace of the velocity field is constructed so that the original saddle point problem can be reduced to a symmetric and positive definite system with much fewer unknowns. The numerical experiments indicate that the method is accurate.

  10. A simple finite element method for the Stokes equations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mu, Lin; Ye, Xiu

    The goal of this paper is to introduce a simple finite element method to solve the Stokes equations. This method is in primal velocity-pressure formulation and is so simple such that both velocity and pressure are approximated by piecewise constant functions. Implementation issues as well as error analysis are investigated. A basis for a divergence free subspace of the velocity field is constructed so that the original saddle point problem can be reduced to a symmetric and positive definite system with much fewer unknowns. The numerical experiments indicate that the method is accurate.

  11. A simple, stable, and accurate linear tetrahedral finite element for transient, nearly, and fully incompressible solid dynamics: A dynamic variational multiscale approach [A simple, stable, and accurate tetrahedral finite element for transient, nearly incompressible, linear and nonlinear elasticity: A dynamic variational multiscale approach

    DOE PAGES

    Scovazzi, Guglielmo; Carnes, Brian; Zeng, Xianyi; ...

    2015-11-12

    Here, we propose a new approach for the stabilization of linear tetrahedral finite elements in the case of nearly incompressible transient solid dynamics computations. Our method is based on a mixed formulation, in which the momentum equation is complemented by a rate equation for the evolution of the pressure field, approximated with piece-wise linear, continuous finite element functions. The pressure equation is stabilized to prevent spurious pressure oscillations in computations. Incidentally, it is also shown that many stabilized methods previously developed for the static case do not generalize easily to transient dynamics. Extensive tests in the context of linear andmore » nonlinear elasticity are used to corroborate the claim that the proposed method is robust, stable, and accurate.« less

  12. A simple, stable, and accurate linear tetrahedral finite element for transient, nearly, and fully incompressible solid dynamics: A dynamic variational multiscale approach [A simple, stable, and accurate tetrahedral finite element for transient, nearly incompressible, linear and nonlinear elasticity: A dynamic variational multiscale approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scovazzi, Guglielmo; Carnes, Brian; Zeng, Xianyi

    Here, we propose a new approach for the stabilization of linear tetrahedral finite elements in the case of nearly incompressible transient solid dynamics computations. Our method is based on a mixed formulation, in which the momentum equation is complemented by a rate equation for the evolution of the pressure field, approximated with piece-wise linear, continuous finite element functions. The pressure equation is stabilized to prevent spurious pressure oscillations in computations. Incidentally, it is also shown that many stabilized methods previously developed for the static case do not generalize easily to transient dynamics. Extensive tests in the context of linear andmore » nonlinear elasticity are used to corroborate the claim that the proposed method is robust, stable, and accurate.« less

  13. The Krylov accelerated SIMPLE(R) method for flow problems in industrial furnaces

    NASA Astrophysics Data System (ADS)

    Vuik, C.; Saghir, A.; Boerstoel, G. P.

    2000-08-01

    Numerical modeling of the melting and combustion process is an important tool in gaining understanding of the physical and chemical phenomena that occur in a gas- or oil-fired glass-melting furnace. The incompressible Navier-Stokes equations are used to model the gas flow in the furnace. The discrete Navier-Stokes equations are solved by the SIMPLE(R) pressure-correction method. In these applications, many SIMPLE(R) iterations are necessary to obtain an accurate solution. In this paper, Krylov accelerated versions are proposed: GCR-SIMPLE(R). The properties of these methods are investigated for a simple two-dimensional flow. Thereafter, the efficiencies of the methods are compared for three-dimensional flows in industrial glass-melting furnaces. Copyright

  14. Testing a simple field method for assessing nitrate removal in riparian zones

    Treesearch

    Philippe Vidon; Michael G. Dosskey

    2008-01-01

    Being able to identify riparian sites that function better for nitrate removal from groundwater is critical to using efficiently the riparian zones for water quality management. For this purpose, managers need a method that is quick, inexpensive, and accurate enough to enable effective management decisions. This study assesses the precision and accuracy of a simple...

  15. Simple method for quick estimation of aquifer hydrogeological parameters

    NASA Astrophysics Data System (ADS)

    Ma, C.; Li, Y. Y.

    2017-08-01

    Development of simple and accurate methods to determine the aquifer hydrogeological parameters was of importance for groundwater resources assessment and management. Aiming at the present issue of estimating aquifer parameters based on some data of the unsteady pumping test, a fitting function of Theis well function was proposed using fitting optimization method and then a unitary linear regression equation was established. The aquifer parameters could be obtained by solving coefficients of the regression equation. The application of the proposed method was illustrated, using two published data sets. By the error statistics and analysis on the pumping drawdown, it showed that the method proposed in this paper yielded quick and accurate estimates of the aquifer parameters. The proposed method could reliably identify the aquifer parameters from long distance observed drawdowns and early drawdowns. It was hoped that the proposed method in this paper would be helpful for practicing hydrogeologists and hydrologists.

  16. A practical model for pressure probe system response estimation (with review of existing models)

    NASA Astrophysics Data System (ADS)

    Hall, B. F.; Povey, T.

    2018-04-01

    The accurate estimation of the unsteady response (bandwidth) of pneumatic pressure probe systems (probe, line and transducer volume) is a common practical problem encountered in the design of aerodynamic experiments. Understanding the bandwidth of the probe system is necessary to capture unsteady flow features accurately. Where traversing probes are used, the desired traverse speed and spatial gradients in the flow dictate the minimum probe system bandwidth required to resolve the flow. Existing approaches for bandwidth estimation are either complex or inaccurate in implementation, so probes are often designed based on experience. Where probe system bandwidth is characterized, it is often done experimentally, requiring careful experimental set-up and analysis. There is a need for a relatively simple but accurate model for estimation of probe system bandwidth. A new model is presented for the accurate estimation of pressure probe bandwidth for simple probes commonly used in wind tunnel environments; experimental validation is provided. An additional, simple graphical method for air is included for convenience.

  17. Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.

    PubMed

    Green, Michael D; Nettey, Henry; Villalva Rojas, Ofelia; Pamanivong, Chansapha; Khounsaknalath, Lamphet; Grande Ortiz, Miguel; Newton, Paul N; Fernández, Facundo M; Vongsack, Latsamy; Manolin, Ot

    2007-01-04

    The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.

  18. Two smart spectrophotometric methods for the simultaneous estimation of Simvastatin and Ezetimibe in combined dosage form

    NASA Astrophysics Data System (ADS)

    Magdy, Nancy; Ayad, Miriam F.

    2015-02-01

    Two simple, accurate, precise, sensitive and economic spectrophotometric methods were developed for the simultaneous determination of Simvastatin and Ezetimibe in fixed dose combination products without prior separation. The first method depends on a new chemometrics-assisted ratio spectra derivative method using moving window polynomial least square fitting method (Savitzky-Golay filters). The second method is based on a simple modification for the ratio subtraction method. The suggested methods were validated according to USP guidelines and can be applied for routine quality control testing.

  19. A novel method for the accurate evaluation of Poisson's ratio of soft polymer materials.

    PubMed

    Lee, Jae-Hoon; Lee, Sang-Soo; Chang, Jun-Dong; Thompson, Mark S; Kang, Dong-Joong; Park, Sungchan; Park, Seonghun

    2013-01-01

    A new method with a simple algorithm was developed to accurately measure Poisson's ratio of soft materials such as polyvinyl alcohol hydrogel (PVA-H) with a custom experimental apparatus consisting of a tension device, a micro X-Y stage, an optical microscope, and a charge-coupled device camera. In the proposed method, the initial positions of the four vertices of an arbitrarily selected quadrilateral from the sample surface were first measured to generate a 2D 1st-order 4-node quadrilateral element for finite element numerical analysis. Next, minimum and maximum principal strains were calculated from differences between the initial and deformed shapes of the quadrilateral under tension. Finally, Poisson's ratio of PVA-H was determined by the ratio of minimum principal strain to maximum principal strain. This novel method has an advantage in the accurate evaluation of Poisson's ratio despite misalignment between specimens and experimental devices. In this study, Poisson's ratio of PVA-H was 0.44 ± 0.025 (n = 6) for 2.6-47.0% elongations with a tendency to decrease with increasing elongation. The current evaluation method of Poisson's ratio with a simple measurement system can be employed to a real-time automated vision-tracking system which is used to accurately evaluate the material properties of various soft materials.

  20. A Simple Plasma Retinol Isotope Ratio Method for Estimating β-Carotene Relative Bioefficacy in Humans: Validation with the Use of Model-Based Compartmental Analysis.

    PubMed

    Ford, Jennifer Lynn; Green, Joanne Balmer; Lietz, Georg; Oxley, Anthony; Green, Michael H

    2017-09-01

    Background: Provitamin A carotenoids are an important source of dietary vitamin A for many populations. Thus, accurate and simple methods for estimating carotenoid bioefficacy are needed to evaluate the vitamin A value of test solutions and plant sources. β-Carotene bioefficacy is often estimated from the ratio of the areas under plasma isotope response curves after subjects ingest labeled β-carotene and a labeled retinyl acetate reference dose [isotope reference method (IRM)], but to our knowledge, the method has not yet been evaluated for accuracy. Objectives: Our objectives were to develop and test a physiologically based compartmental model that includes both absorptive and postabsorptive β-carotene bioconversion and to use the model to evaluate the accuracy of the IRM and a simple plasma retinol isotope ratio [(RIR), labeled β-carotene-derived retinol/labeled reference-dose-derived retinol in one plasma sample] for estimating relative bioefficacy. Methods: We used model-based compartmental analysis (Simulation, Analysis and Modeling software) to develop and apply a model that provided known values for β-carotene bioefficacy. Theoretical data for 10 subjects were generated by the model and used to determine bioefficacy by RIR and IRM; predictions were compared with known values. We also applied RIR and IRM to previously published data. Results: Plasma RIR accurately predicted β-carotene relative bioefficacy at 14 d or later. IRM also accurately predicted bioefficacy by 14 d, except that, when there was substantial postabsorptive bioconversion, IRM underestimated bioefficacy. Based on our model, 1-d predictions of relative bioefficacy include absorptive plus a portion of early postabsorptive conversion. Conclusion: The plasma RIR is a simple tracer method that accurately predicts β-carotene relative bioefficacy based on analysis of one blood sample obtained at ≥14 d after co-ingestion of labeled β-carotene and retinyl acetate. The method also provides information about the contributions of absorptive and postabsorptive conversion to total bioefficacy if an additional sample is taken at 1 d. © 2017 American Society for Nutrition.

  1. Accurate mass measurement by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry. I. Measurement of positive radical ions using porphyrin standard reference materials.

    PubMed

    Griffiths, Nia W; Wyatt, Mark F; Kean, Suzanna D; Graham, Andrew E; Stein, Bridget K; Brenton, A Gareth

    2010-06-15

    A method for the accurate mass measurement of positive radical ions by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) is described. Initial use of a conjugated oligomeric calibration material was rejected in favour of a series of meso-tetraalkyl/tetraalkylaryl-functionalised porphyrins, from which the two calibrants required for a particular accurate mass measurement were chosen. While all measurements of monoisotopic species were within +/-5 ppm, and the method was rigorously validated using chemometrics, mean values of five measurements were used for extra confidence in the generation of potential elemental formulae. Potential difficulties encountered when measuring compounds containing multi-isotopic elements are discussed, where the monoisotopic peak is no longer the lowest mass peak, and a simple mass-correction solution can be applied. The method requires no significant expertise to implement, but care and attention is required to obtain valid measurements. The method is operationally simple and will prove useful to the analytical chemistry community. Copyright (c) 2010 John Wiley & Sons, Ltd.

  2. Phonon scattering in nanoscale systems: lowest order expansion of the current and power expressions

    NASA Astrophysics Data System (ADS)

    Paulsson, Magnus; Frederiksen, Thomas; Brandbyge, Mads

    2006-04-01

    We use the non-equilibrium Green's function method to describe the effects of phonon scattering on the conductance of nano-scale devices. Useful and accurate approximations are developed that both provide (i) computationally simple formulas for large systems and (ii) simple analytical models. In addition, the simple models can be used to fit experimental data and provide physical parameters.

  3. Comparative Validation of the Determination of Sofosbuvir in Pharmaceuticals by Several Inexpensive Ecofriendly Chromatographic, Electrophoretic, and Spectrophotometric Methods.

    PubMed

    El-Yazbi, Amira F

    2017-07-01

    Sofosbuvir (SOFO) was approved by the U.S. Food and Drug Administration in 2013 for the treatment of hepatitis C virus infection with enhanced antiviral potency compared with earlier analogs. Notwithstanding, all current editions of the pharmacopeias still do not present any analytical methods for the quantification of SOFO. Thus, rapid, simple, and ecofriendly methods for the routine analysis of commercial formulations of SOFO are desirable. In this study, five accurate methods for the determination of SOFO in pharmaceutical tablets were developed and validated. These methods include HPLC, capillary zone electrophoresis, HPTLC, and UV spectrophotometric and derivative spectrometry methods. The proposed methods proved to be rapid, simple, sensitive, selective, and accurate analytical procedures that were suitable for the reliable determination of SOFO in pharmaceutical tablets. An analysis of variance test with P-value > 0.05 confirmed that there were no significant differences between the proposed assays. Thus, any of these methods can be used for the routine analysis of SOFO in commercial tablets.

  4. Compression-based distance (CBD): a simple, rapid, and accurate method for microbiota composition comparison

    PubMed Central

    2013-01-01

    Background Perturbations in intestinal microbiota composition have been associated with a variety of gastrointestinal tract-related diseases. The alleviation of symptoms has been achieved using treatments that alter the gastrointestinal tract microbiota toward that of healthy individuals. Identifying differences in microbiota composition through the use of 16S rRNA gene hypervariable tag sequencing has profound health implications. Current computational methods for comparing microbial communities are usually based on multiple alignments and phylogenetic inference, making them time consuming and requiring exceptional expertise and computational resources. As sequencing data rapidly grows in size, simpler analysis methods are needed to meet the growing computational burdens of microbiota comparisons. Thus, we have developed a simple, rapid, and accurate method, independent of multiple alignments and phylogenetic inference, to support microbiota comparisons. Results We create a metric, called compression-based distance (CBD) for quantifying the degree of similarity between microbial communities. CBD uses the repetitive nature of hypervariable tag datasets and well-established compression algorithms to approximate the total information shared between two datasets. Three published microbiota datasets were used as test cases for CBD as an applicable tool. Our study revealed that CBD recaptured 100% of the statistically significant conclusions reported in the previous studies, while achieving a decrease in computational time required when compared to similar tools without expert user intervention. Conclusion CBD provides a simple, rapid, and accurate method for assessing distances between gastrointestinal tract microbiota 16S hypervariable tag datasets. PMID:23617892

  5. Compression-based distance (CBD): a simple, rapid, and accurate method for microbiota composition comparison.

    PubMed

    Yang, Fang; Chia, Nicholas; White, Bryan A; Schook, Lawrence B

    2013-04-23

    Perturbations in intestinal microbiota composition have been associated with a variety of gastrointestinal tract-related diseases. The alleviation of symptoms has been achieved using treatments that alter the gastrointestinal tract microbiota toward that of healthy individuals. Identifying differences in microbiota composition through the use of 16S rRNA gene hypervariable tag sequencing has profound health implications. Current computational methods for comparing microbial communities are usually based on multiple alignments and phylogenetic inference, making them time consuming and requiring exceptional expertise and computational resources. As sequencing data rapidly grows in size, simpler analysis methods are needed to meet the growing computational burdens of microbiota comparisons. Thus, we have developed a simple, rapid, and accurate method, independent of multiple alignments and phylogenetic inference, to support microbiota comparisons. We create a metric, called compression-based distance (CBD) for quantifying the degree of similarity between microbial communities. CBD uses the repetitive nature of hypervariable tag datasets and well-established compression algorithms to approximate the total information shared between two datasets. Three published microbiota datasets were used as test cases for CBD as an applicable tool. Our study revealed that CBD recaptured 100% of the statistically significant conclusions reported in the previous studies, while achieving a decrease in computational time required when compared to similar tools without expert user intervention. CBD provides a simple, rapid, and accurate method for assessing distances between gastrointestinal tract microbiota 16S hypervariable tag datasets.

  6. Analysis and calculation by integral methods of laminar compressible boundary-layer with heat transfer and with and without pressure gradient

    NASA Technical Reports Server (NTRS)

    Morduchow, Morris

    1955-01-01

    A survey of integral methods in laminar-boundary-layer analysis is first given. A simple and sufficiently accurate method for practical purposes of calculating the properties (including stability) of the laminar compressible boundary layer in an axial pressure gradient with heat transfer at the wall is presented. For flow over a flat plate, the method is applicable for an arbitrarily prescribed distribution of temperature along the surface and for any given constant Prandtl number close to unity. For flow in a pressure gradient, the method is based on a Prandtl number of unity and a uniform wall temperature. A simple and accurate method of determining the separation point in a compressible flow with an adverse pressure gradient over a surface at a given uniform wall temperature is developed. The analysis is based on an extension of the Karman-Pohlhausen method to the momentum and the thermal energy equations in conjunction with fourth- and especially higher degree velocity and stagnation-enthalpy profiles.

  7. A Simple Accurate Alternative to the Minimum-Deviation Method for the Determination of the Refractive Index of a Prism.

    ERIC Educational Resources Information Center

    Waldenstrom, S.; Naqvi, K. Razi

    1978-01-01

    Proposes an alternative to the classical minimum-deviation method for determining the refractive index of a prism. This new "fixed angle of incidence method" may find applications in research. (Author/GA)

  8. Simple and Accurate Method for Central Spin Problems

    NASA Astrophysics Data System (ADS)

    Lindoy, Lachlan P.; Manolopoulos, David E.

    2018-06-01

    We describe a simple quantum mechanical method that can be used to obtain accurate numerical results over long timescales for the spin correlation tensor of an electron spin that is hyperfine coupled to a large number of nuclear spins. This method does not suffer from the statistical errors that accompany a Monte Carlo sampling of the exact eigenstates of the central spin Hamiltonian obtained from the algebraic Bethe ansatz, or from the growth of the truncation error with time in the time-dependent density matrix renormalization group (TDMRG) approach. As a result, it can be applied to larger central spin problems than the algebraic Bethe ansatz, and for longer times than the TDMRG algorithm. It is therefore an ideal method to use to solve central spin problems, and we expect that it will also prove useful for a variety of related problems that arise in a number of different research fields.

  9. Simple Criteria to Determine the Set of Key Parameters of the DRPE Method by a Brute-force Attack

    NASA Astrophysics Data System (ADS)

    Nalegaev, S. S.; Petrov, N. V.

    Known techniques of breaking Double Random Phase Encoding (DRPE), which bypass the resource-intensive brute-force method, require at least two conditions: the attacker knows the encryption algorithm; there is an access to the pairs of source and encoded images. Our numerical results show that for the accurate recovery by numerical brute-force attack, someone needs only some a priori information about the source images, which can be quite general. From the results of our numerical experiments with optical data encryption DRPE with digital holography, we have proposed four simple criteria for guaranteed and accurate data recovery. These criteria can be applied, if the grayscale, binary (including QR-codes) or color images are used as a source.

  10. A pilot study to explore the feasibility of using theClinical Care Classification System for developing a reliable costing method for nursing services.

    PubMed

    Dykes, Patricia C; Wantland, Dean; Whittenburg, Luann; Lipsitz, Stuart; Saba, Virginia K

    2013-01-01

    While nursing activities represent a significant proportion of inpatient care, there are no reliable methods for determining nursing costs based on the actual services provided by the nursing staff. Capture of data to support accurate measurement and reporting on the cost of nursing services is fundamental to effective resource utilization. Adopting standard terminologies that support tracking both the quality and the cost of care could reduce the data entry burden on direct care providers. This pilot study evaluated the feasibility of using a standardized nursing terminology, the Clinical Care Classification System (CCC), for developing a reliable costing method for nursing services. Two different approaches are explored; the Relative Value Unit RVU and the simple cost-to-time methods. We found that the simple cost-to-time method was more accurate and more transparent in its derivation than the RVU method and may support a more consistent and reliable approach for costing nursing services.

  11. Quantitative determination of some pharmaceutical piperazine derivatives through complexation with iron(III) chloride.

    PubMed

    Abou-Attia, F M; Issa, Y M; Abdel-Gawad, F M; Abdel-Hamid, S M

    2003-08-01

    A simple, accurate and sensitive spectrophotometric method has been developed for the determination of three pharmaceutical piperazine derivatives, namely ketoconazole (KC), trimetazidine hydrochloride (TMH) and piribedil (PD). This method is based on the formation of yellow orange complexes between iron(III) chloride and the investigated drugs. The optimum reaction conditions, spectral characteristics, conditional stability constants and composition of the water soluble complexes have been established. The method permits the determination of KC, TMH and PD over a concentration range 1-15, 1-12 and 1-12 microg ml(-1), respectively. Sandell sensitivity is found to be 0.016, 0.013 and 0.013 microg cm(-2) for KC, TMH and PD, respectively. The method was sensitive, simple, reproducible and accurate within +/-1.5%. The method is applicable to the assay of the three drugs under investigation in different dosage forms and the results are in good agreement with those obtained by the official methods (USP and JP).

  12. A comparison of quantitative methods for clinical imaging with hyperpolarized (13)C-pyruvate.

    PubMed

    Daniels, Charlie J; McLean, Mary A; Schulte, Rolf F; Robb, Fraser J; Gill, Andrew B; McGlashan, Nicholas; Graves, Martin J; Schwaiger, Markus; Lomas, David J; Brindle, Kevin M; Gallagher, Ferdia A

    2016-04-01

    Dissolution dynamic nuclear polarization (DNP) enables the metabolism of hyperpolarized (13)C-labelled molecules, such as the conversion of [1-(13)C]pyruvate to [1-(13)C]lactate, to be dynamically and non-invasively imaged in tissue. Imaging of this exchange reaction in animal models has been shown to detect early treatment response and correlate with tumour grade. The first human DNP study has recently been completed, and, for widespread clinical translation, simple and reliable methods are necessary to accurately probe the reaction in patients. However, there is currently no consensus on the most appropriate method to quantify this exchange reaction. In this study, an in vitro system was used to compare several kinetic models, as well as simple model-free methods. Experiments were performed using a clinical hyperpolarizer, a human 3 T MR system, and spectroscopic imaging sequences. The quantitative methods were compared in vivo by using subcutaneous breast tumours in rats to examine the effect of pyruvate inflow. The two-way kinetic model was the most accurate method for characterizing the exchange reaction in vitro, and the incorporation of a Heaviside step inflow profile was best able to describe the in vivo data. The lactate time-to-peak and the lactate-to-pyruvate area under the curve ratio were simple model-free approaches that accurately represented the full reaction, with the time-to-peak method performing indistinguishably from the best kinetic model. Finally, extracting data from a single pixel was a robust and reliable surrogate of the whole region of interest. This work has identified appropriate quantitative methods for future work in the analysis of human hyperpolarized (13)C data. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

  13. The generalized scattering coefficient method for plane wave scattering in layered structures

    NASA Astrophysics Data System (ADS)

    Liu, Yu; Li, Chao; Wang, Huai-Yu; Zhou, Yun-Song

    2017-02-01

    The generalized scattering coefficient (GSC) method is pedagogically derived and employed to study the scattering of plane waves in homogeneous and inhomogeneous layered structures. The numerical stabilities and accuracies of this method and other commonly used numerical methods are discussed and compared. For homogeneous layered structures, concise scattering formulas with clear physical interpretations and strong numerical stability are obtained by introducing the GSCs. For inhomogeneous layered structures, three numerical methods are employed: the staircase approximation method, the power series expansion method, and the differential equation based on the GSCs. We investigate the accuracies and convergence behaviors of these methods by comparing their predictions to the exact results. The conclusions are as follows. The staircase approximation method has a slow convergence in spite of its simple and intuitive implementation, and a fine stratification within the inhomogeneous layer is required for obtaining accurate results. The expansion method results are sensitive to the expansion order, and the treatment becomes very complicated for relatively complex configurations, which restricts its applicability. By contrast, the GSC-based differential equation possesses a simple implementation while providing fast and accurate results.

  14. Local SIMPLE multi-atlas-based segmentation applied to lung lobe detection on chest CT

    NASA Astrophysics Data System (ADS)

    Agarwal, M.; Hendriks, E. A.; Stoel, B. C.; Bakker, M. E.; Reiber, J. H. C.; Staring, M.

    2012-02-01

    For multi atlas-based segmentation approaches, a segmentation fusion scheme which considers local performance measures may be more accurate than a method which uses a global performance measure. We improve upon an existing segmentation fusion method called SIMPLE and extend it to be localized and suitable for multi-labeled segmentations. We demonstrate the algorithm performance on 23 CT scans of COPD patients using a leave-one- out experiment. Our algorithm performs significantly better (p < 0.01) than majority voting, STAPLE, and SIMPLE, with a median overlap of the fissure of 0.45, 0.48, 0.55 and 0.6 for majority voting, STAPLE, SIMPLE, and the proposed algorithm, respectively.

  15. An unexpected way forward: towards a more accurate and rigorous protein-protein binding affinity scoring function by eliminating terms from an already simple scoring function.

    PubMed

    Swanson, Jon; Audie, Joseph

    2018-01-01

    A fundamental and unsolved problem in biophysical chemistry is the development of a computationally simple, physically intuitive, and generally applicable method for accurately predicting and physically explaining protein-protein binding affinities from protein-protein interaction (PPI) complex coordinates. Here, we propose that the simplification of a previously described six-term PPI scoring function to a four term function results in a simple expression of all physically and statistically meaningful terms that can be used to accurately predict and explain binding affinities for a well-defined subset of PPIs that are characterized by (1) crystallographic coordinates, (2) rigid-body association, (3) normal interface size, and hydrophobicity and hydrophilicity, and (4) high quality experimental binding affinity measurements. We further propose that the four-term scoring function could be regarded as a core expression for future development into a more general PPI scoring function. Our work has clear implications for PPI modeling and structure-based drug design.

  16. Accurate radiative transfer calculations for layered media.

    PubMed

    Selden, Adrian C

    2016-07-01

    Simple yet accurate results for radiative transfer in layered media with discontinuous refractive index are obtained by the method of K-integrals. These are certain weighted integrals applied to the angular intensity distribution at the refracting boundaries. The radiative intensity is expressed as the sum of the asymptotic angular intensity distribution valid in the depth of the scattering medium and a transient term valid near the boundary. Integrated boundary equations are obtained, yielding simple linear equations for the intensity coefficients, enabling the angular emission intensity and the diffuse reflectance (albedo) and transmittance of the scattering layer to be calculated without solving the radiative transfer equation directly. Examples are given of half-space, slab, interface, and double-layer calculations, and extensions to multilayer systems are indicated. The K-integral method is orders of magnitude more accurate than diffusion theory and can be applied to layered scattering media with a wide range of scattering albedos, with potential applications to biomedical and ocean optics.

  17. Linear segmentation algorithm for detecting layer boundary with lidar.

    PubMed

    Mao, Feiyue; Gong, Wei; Logan, Timothy

    2013-11-04

    The automatic detection of aerosol- and cloud-layer boundary (base and top) is important in atmospheric lidar data processing, because the boundary information is not only useful for environment and climate studies, but can also be used as input for further data processing. Previous methods have demonstrated limitations in defining the base and top, window-size setting, and have neglected the in-layer attenuation. To overcome these limitations, we present a new layer detection scheme for up-looking lidars based on linear segmentation with a reasonable threshold setting, boundary selecting, and false positive removing strategies. Preliminary results from both real and simulated data show that this algorithm cannot only detect the layer-base as accurate as the simple multi-scale method, but can also detect the layer-top more accurately than that of the simple multi-scale method. Our algorithm can be directly applied to uncalibrated data without requiring any additional measurements or window size selections.

  18. Comparative Validation of the Determination of Sofosbuvir in Pharmaceuticals by Several Inexpensive Ecofriendly Chromatographic, Electrophoretic, and Spectrophotometric Methods.

    PubMed

    El-Yazbi, Amira F

    2017-01-20

    Sofosbuvir (SOFO) was approved by the U.S. Food and Drug Administration in 2013 for the treatment of hepatitis C virusinfection with enhanced antiviral potency compared with earlier analogs. Notwithstanding, all current editions of the pharmacopeias still do not present any analytical methods for the quantification of SOFO. Thus, rapid, simple, and ecofriendly methods for the routine analysis of commercial formulations of SOFO are desirable. In this study, five accurate methods for the determination of SOFO in pharmaceutical tablets were developed and validated. These methods include HPLC, capillary zone electrophoresis, HPTLC, and UV spectrophotometric and derivative spectrometry methods. The proposed methods proved to be rapid, simple, sensitive, selective, and accurate analytical procedures that were suitable for the reliable determination of SOFO in pharmaceutical tablets. An analysis of variance test with <em>P</em>-value &#x003E; 0.05 confirmed that there were no significant differences between the proposed assays. Thus, any of these methods can be used for the routine analysis of SOFO in commercial tablets.

  19. The Measurement of the Specific Latent Heat of Fusion of Ice: Two Improved Methods.

    ERIC Educational Resources Information Center

    Mak, S. Y.; Chun, C. K. W.

    2000-01-01

    Suggests two methods for measuring the specific latent heat of ice fusion for high school physics laboratories. The first method is an ice calorimeter which is made from simple materials. The second method improves the thermal contact and allows for a more accurate measurement. Lists instructions for both methods. (Author/YDS)

  20. Accurate, high-throughput typing of copy number variation using paralogue ratios from dispersed repeats

    PubMed Central

    Armour, John A. L.; Palla, Raquel; Zeeuwen, Patrick L. J. M.; den Heijer, Martin; Schalkwijk, Joost; Hollox, Edward J.

    2007-01-01

    Recent work has demonstrated an unexpected prevalence of copy number variation in the human genome, and has highlighted the part this variation may play in predisposition to common phenotypes. Some important genes vary in number over a high range (e.g. DEFB4, which commonly varies between two and seven copies), and have posed formidable technical challenges for accurate copy number typing, so that there are no simple, cheap, high-throughput approaches suitable for large-scale screening. We have developed a simple comparative PCR method based on dispersed repeat sequences, using a single pair of precisely designed primers to amplify products simultaneously from both test and reference loci, which are subsequently distinguished and quantified via internal sequence differences. We have validated the method for the measurement of copy number at DEFB4 by comparison of results from >800 DNA samples with copy number measurements by MAPH/REDVR, MLPA and array-CGH. The new Paralogue Ratio Test (PRT) method can require as little as 10 ng genomic DNA, appears to be comparable in accuracy to the other methods, and for the first time provides a rapid, simple and inexpensive method for copy number analysis, suitable for application to typing thousands of samples in large case-control association studies. PMID:17175532

  1. An efficient transport solver for tokamak plasmas

    DOE PAGES

    Park, Jin Myung; Murakami, Masanori; St. John, H. E.; ...

    2017-01-03

    A simple approach to efficiently solve a coupled set of 1-D diffusion-type transport equations with a stiff transport model for tokamak plasmas is presented based on the 4th order accurate Interpolated Differential Operator scheme along with a nonlinear iteration method derived from a root-finding algorithm. Here, numerical tests using the Trapped Gyro-Landau-Fluid model show that the presented high order method provides an accurate transport solution using a small number of grid points with robust nonlinear convergence.

  2. A simple and inclusive method to determine the habit plane in transmission electron microscope based on accurate measurement of foil thickness

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qiu, Dong, E-mail: d.qiu@uq.edu.au; Zhang, Mingxing

    2014-08-15

    A simple and inclusive method is proposed for accurate determination of the habit plane between bicrystals in transmission electron microscope. Whilst this method can be regarded as a variant of surface trace analysis, the major innovation lies in the improved accuracy and efficiency of foil thickness measurement, which involves a simple tilt of the thin foil about a permanent tilting axis of the specimen holder, rather than cumbersome tilt about the surface trace of the habit plane. Experimental study has been done to validate this proposed method in determining the habit plane between lamellar α{sub 2} plates and γ matrixmore » in a Ti–Al–Nb alloy. Both high accuracy (± 1°) and high precision (± 1°) have been achieved by using the new method. The source of the experimental errors as well as the applicability of this method is discussed. Some tips to minimise the experimental errors are also suggested. - Highlights: • An improved algorithm is formulated to measure the foil thickness. • Habit plane can be determined with a single tilt holder based on the new algorithm. • Better accuracy and precision within ± 1° are achievable using the proposed method. • The data for multi-facet determination can be collected simultaneously.« less

  3. Profitable capitation requires accurate costing.

    PubMed

    West, D A; Hicks, L L; Balas, E A; West, T D

    1996-01-01

    In the name of costing accuracy, nurses are asked to track inventory use on per treatment basis when more significant costs, such as general overhead and nursing salaries, are usually allocated to patients or treatments on an average cost basis. Accurate treatment costing and financial viability require analysis of all resources actually consumed in treatment delivery, including nursing services and inventory. More precise costing information enables more profitable decisions as is demonstrated by comparing the ratio-of-cost-to-treatment method (aggregate costing) with alternative activity-based costing methods (ABC). Nurses must participate in this costing process to assure that capitation bids are based upon accurate costs rather than simple averages.

  4. Deconvolution method for accurate determination of overlapping peak areas in chromatograms.

    PubMed

    Nelson, T J

    1991-12-20

    A method is described for deconvoluting chromatograms which contain overlapping peaks. Parameters can be selected to ensure that attenuation of peak areas is uniform over any desired range of peak widths. A simple extension of the method greatly reduces the negative overshoot frequently encountered with deconvolutions. The deconvoluted chromatograms are suitable for integration by conventional methods.

  5. Gasometric Determination of CO[subscript 2] Released from Carbonate Materials

    ERIC Educational Resources Information Center

    Fagerlund, Johan; Zevenhoven, Ron; Hulden, Stig-Goran; Sodergard, Berndt

    2010-01-01

    To determine the carbonation degree of materials used in mineral carbonation experiments, a fast, simple, and sufficiently accurate method is required. For this purpose, a method based on the reaction between carbonates and hydrochloric acid was developed. It was noted that this method could also be used to teach undergraduate students some basic…

  6. Simple estimate of critical volume

    NASA Technical Reports Server (NTRS)

    Fedors, R. F.

    1980-01-01

    Method for estimating critical molar volume of materials is faster and simpler than previous procedures. Formula sums no more than 18 different contributions from components of chemical structure of material, and is as accurate (within 3 percent) as older more complicated models. Method should expedite many thermodynamic design calculations.

  7. Calculation of Temperature Rise in Calorimetry.

    ERIC Educational Resources Information Center

    Canagaratna, Sebastian G.; Witt, Jerry

    1988-01-01

    Gives a simple but fuller account of the basis for accurately calculating temperature rise in calorimetry. Points out some misconceptions regarding these calculations. Describes two basic methods, the extrapolation to zero time and the equal area method. Discusses the theoretical basis of each and their underlying assumptions. (CW)

  8. Multiplexed microsatellite recovery using massively parallel sequencing

    Treesearch

    T.N. Jennings; B.J. Knaus; T.D. Mullins; S.M. Haig; R.C. Cronn

    2011-01-01

    Conservation and management of natural populations requires accurate and inexpensive genotyping methods. Traditional microsatellite, or simple sequence repeat (SSR), marker analysis remains a popular genotyping method because of the comparatively low cost of marker development, ease of analysis and high power of genotype discrimination. With the availability of...

  9. Simple and accurate sum rules for highly relativistic systems

    NASA Astrophysics Data System (ADS)

    Cohen, Scott M.

    2005-03-01

    In this paper, I consider the Bethe and Thomas-Reiche-Kuhn sum rules, which together form the foundation of Bethe's theory of energy loss from fast charged particles to matter. For nonrelativistic target systems, the use of closure leads directly to simple expressions for these quantities. In the case of relativistic systems, on the other hand, the calculation of sum rules is fraught with difficulties. Various perturbative approaches have been used over the years to obtain relativistic corrections, but these methods fail badly when the system in question is very strongly bound. Here, I present an approach that leads to relatively simple expressions yielding accurate sums, even for highly relativistic many-electron systems. I also offer an explanation for the difference between relativistic and nonrelativistic sum rules in terms of the Zitterbewegung of the electrons.

  10. SU-F-T-486: A Simple Approach to Performing Light Versus Radiation Field Coincidence Quality Assurance Using An Electronic Portal Imaging Device (EPID)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herchko, S; Ding, G

    2016-06-15

    Purpose: To develop an accurate, straightforward, and user-independent method for performing light versus radiation field coincidence quality assurance utilizing EPID images, a simple phantom made of readily-accessible materials, and a free software program. Methods: A simple phantom consisting of a blocking tray, graph paper, and high-density wire was constructed. The phantom was used to accurately set the size of a desired light field and imaged on the electronic portal imaging device (EPID). A macro written for use in ImageJ, a free image processing software, was then use to determine the radiation field size utilizing the high density wires on themore » phantom for a pixel to distance calibration. The macro also performs an analysis on the measured radiation field utilizing the tolerances recommended in the AAPM Task Group #142. To verify the accuracy of this method, radiochromic film was used to qualitatively demonstrate agreement between the film and EPID results, and an additional ImageJ macro was used to quantitatively compare the radiation field sizes measured both with the EPID and film images. Results: The results of this technique were benchmarked against film measurements, which have been the gold standard for testing light versus radiation field coincidence. The agreement between this method and film measurements were within 0.5 mm. Conclusion: Due to the operator dependency associated with tracing light fields and measuring radiation fields by hand when using film, this method allows for a more accurate comparison between the light and radiation fields with minimal operator dependency. Removing the need for radiographic or radiochromic film also eliminates a reoccurring cost and increases procedural efficiency.« less

  11. An Accurate Non-Cooperative Method for Measuring Textureless Spherical Target Based on Calibrated Lasers.

    PubMed

    Wang, Fei; Dong, Hang; Chen, Yanan; Zheng, Nanning

    2016-12-09

    Strong demands for accurate non-cooperative target measurement have been arising recently for the tasks of assembling and capturing. Spherical objects are one of the most common targets in these applications. However, the performance of the traditional vision-based reconstruction method was limited for practical use when handling poorly-textured targets. In this paper, we propose a novel multi-sensor fusion system for measuring and reconstructing textureless non-cooperative spherical targets. Our system consists of four simple lasers and a visual camera. This paper presents a complete framework of estimating the geometric parameters of textureless spherical targets: (1) an approach to calibrate the extrinsic parameters between a camera and simple lasers; and (2) a method to reconstruct the 3D position of the laser spots on the target surface and achieve the refined results via an optimized scheme. The experiment results show that our proposed calibration method can obtain a fine calibration result, which is comparable to the state-of-the-art LRF-based methods, and our calibrated system can estimate the geometric parameters with high accuracy in real time.

  12. 3D Boolean operations in virtual surgical planning.

    PubMed

    Charton, Jerome; Laurentjoye, Mathieu; Kim, Youngjun

    2017-10-01

    Boolean operations in computer-aided design or computer graphics are a set of operations (e.g. intersection, union, subtraction) between two objects (e.g. a patient model and an implant model) that are important in performing accurate and reproducible virtual surgical planning. This requires accurate and robust techniques that can handle various types of data, such as a surface extracted from volumetric data, synthetic models, and 3D scan data. This article compares the performance of the proposed method (Boolean operations by a robust, exact, and simple method between two colliding shells (BORES)) and an existing method based on the Visualization Toolkit (VTK). In all tests presented in this article, BORES could handle complex configurations as well as report impossible configurations of the input. In contrast, the VTK implementations were unstable, do not deal with singular edges and coplanar collisions, and have created several defects. The proposed method of Boolean operations, BORES, is efficient and appropriate for virtual surgical planning. Moreover, it is simple and easy to implement. In future work, we will extend the proposed method to handle non-colliding components.

  13. An Accurate Non-Cooperative Method for Measuring Textureless Spherical Target Based on Calibrated Lasers

    PubMed Central

    Wang, Fei; Dong, Hang; Chen, Yanan; Zheng, Nanning

    2016-01-01

    Strong demands for accurate non-cooperative target measurement have been arising recently for the tasks of assembling and capturing. Spherical objects are one of the most common targets in these applications. However, the performance of the traditional vision-based reconstruction method was limited for practical use when handling poorly-textured targets. In this paper, we propose a novel multi-sensor fusion system for measuring and reconstructing textureless non-cooperative spherical targets. Our system consists of four simple lasers and a visual camera. This paper presents a complete framework of estimating the geometric parameters of textureless spherical targets: (1) an approach to calibrate the extrinsic parameters between a camera and simple lasers; and (2) a method to reconstruct the 3D position of the laser spots on the target surface and achieve the refined results via an optimized scheme. The experiment results show that our proposed calibration method can obtain a fine calibration result, which is comparable to the state-of-the-art LRF-based methods, and our calibrated system can estimate the geometric parameters with high accuracy in real time. PMID:27941705

  14. A Simpler Way to Tame Multiple-Effect Evaporators.

    ERIC Educational Resources Information Center

    Joye, Donald D.; Koko, F. William Jr.

    1988-01-01

    Presents a new method to teach the subject of evaporators which is both simple enough to use in the classroom and accurate and flexible enough to be used as a design tool in practice. Gives an example using a triple evaporator series. Analyzes the effect of this method. (CW)

  15. An implicit semianalytic numerical method for the solution of nonequilibrium chemistry problems

    NASA Technical Reports Server (NTRS)

    Graves, R. A., Jr.; Gnoffo, P. A.; Boughner, R. E.

    1974-01-01

    The first order differential equation form systems of equations. They are solved by a simple and relatively accurate implicit semianalytic technique which is derived from a quadrature solution of the governing equation. This method is mathematically simpler than most implicit methods and has the exponential nature of the problem embedded in the solution.

  16. Reflective array modeling for reflective and directional SAW transducers.

    PubMed

    Morgan, D P

    1998-01-01

    This paper presents a new approximate method for analyzing reflective SAW transducers, with much of the convenience of the coupled-mode (COM) method but with better accuracy. Transduction accuracy is obtained by incorporating the accurate electrostatic solution, giving for example correct harmonics, and allowance for electrode width variation, in a simple manner. Results are shown for a single-electrode transducer, Natural SPUDT and DART SPUDT, each using theoretically derived parameters. In contrast to the COM, the RAM can give accurate results for short or withdrawal-weighted transducers and for wide analysis bandwidth.

  17. Accurate Energy Transaction Allocation using Path Integration and Interpolation

    NASA Astrophysics Data System (ADS)

    Bhide, Mandar Mohan

    This thesis investigates many of the popular cost allocation methods which are based on actual usage of the transmission network. The Energy Transaction Allocation (ETA) method originally proposed by A.Fradi, S.Brigonne and B.Wollenberg which gives unique advantage of accurately allocating the transmission network usage is discussed subsequently. Modified calculation of ETA based on simple interpolation technique is then proposed. The proposed methodology not only increase the accuracy of calculation but also decreases number of calculations to less than half of the number of calculations required in original ETAs.

  18. Measurement of Antenna Bore-Sight Gain

    NASA Technical Reports Server (NTRS)

    Fortinberry, Jarrod; Shumpert, Thomas

    2016-01-01

    The absolute or free-field gain of a simple antenna can be approximated using standard antenna theory formulae or for a more accurate prediction, numerical methods may be employed to solve for antenna parameters including gain. Both of these methods will result in relatively reasonable estimates but in practice antenna gain is usually verified and documented via measurements and calibration. In this paper, a relatively simple and low-cost, yet effective means of determining the bore-sight free-field gain of a VHF/UHF antenna is proposed by using the Brewster angle relationship.

  19. Tracking of electrochemical impedance of batteries

    NASA Astrophysics Data System (ADS)

    Piret, H.; Granjon, P.; Guillet, N.; Cattin, V.

    2016-04-01

    This paper presents an evolutionary battery impedance estimation method, which can be easily embedded in vehicles or nomad devices. The proposed method not only allows an accurate frequency impedance estimation, but also a tracking of its temporal evolution contrary to classical electrochemical impedance spectroscopy methods. Taking into account constraints of cost and complexity, we propose to use the existing electronics of current control to perform a frequency evolutionary estimation of the electrochemical impedance. The developed method uses a simple wideband input signal, and relies on a recursive local average of Fourier transforms. The averaging is controlled by a single parameter, managing a trade-off between tracking and estimation performance. This normalized parameter allows to correctly adapt the behavior of the proposed estimator to the variations of the impedance. The advantage of the proposed method is twofold: the method is easy to embed into a simple electronic circuit, and the battery impedance estimator is evolutionary. The ability of the method to monitor the impedance over time is demonstrated on a simulator, and on a real Lithium ion battery, on which a repeatability study is carried out. The experiments reveal good tracking results, and estimation performance as accurate as the usual laboratory approaches.

  20. Application of Certain π-Acceptors for the Spectrophotometric Determination of Alendronate Sodium in Pharmaceutical Bulk and Dosage Forms.

    PubMed

    Raza, Asad; Zia-Ul-Haq, Muhammad

    2011-01-01

    Two simple, fast, and accurate spectrophotometric methods for the determination of alendronate sodium are described. The methods are based on charge-transfer complex formation of the drug with two π-electron acceptors 7,7,7,8-tetracyanoquinodimethane (TCNQ) and 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) in acetonitrile and methanol medium. The methods are followed spectrophotometrically by measuring the maximum absorbance at 840 nm and 465 nm, respectively. Under the optimized experimental conditions, the calibration curves showed a linear relationship over the concentration ranges of 2-10 μg mL(-1) and 2-12 μg mL(-1), respectively. The optimal reactions conditions values such as the reagent concentration, heating time, and stability of reaction product were determined. No significant difference was obtained between the results of newly proposed methods and the B.P. Titrimetric procedures. The charge transfer approach using TCNQ and DDQ procedures described in this paper is simple, fast, accurate, precise, and extraction-free.

  1. Application of Certain π-Acceptors for the Spectrophotometric Determination of Alendronate Sodium in Pharmaceutical Bulk and Dosage Forms

    PubMed Central

    Raza, Asad; Zia-ul-Haq, Muhammad

    2011-01-01

    Two simple, fast, and accurate spectrophotometric methods for the determination of alendronate sodium are described. The methods are based on charge-transfer complex formation of the drug with two π-electron acceptors 7,7,7,8-tetracyanoquinodimethane (TCNQ) and 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) in acetonitrile and methanol medium. The methods are followed spectrophotometrically by measuring the maximum absorbance at 840 nm and 465 nm, respectively. Under the optimized experimental conditions, the calibration curves showed a linear relationship over the concentration ranges of 2–10 μg mL−1 and 2–12 μg mL−1, respectively. The optimal reactions conditions values such as the reagent concentration, heating time, and stability of reaction product were determined. No significant difference was obtained between the results of newly proposed methods and the B.P. Titrimetric procedures. The charge transfer approach using TCNQ and DDQ procedures described in this paper is simple, fast, accurate, precise, and extraction-free. PMID:21760789

  2. Highly accurate symplectic element based on two variational principles

    NASA Astrophysics Data System (ADS)

    Qing, Guanghui; Tian, Jia

    2018-02-01

    For the stability requirement of numerical resultants, the mathematical theory of classical mixed methods are relatively complex. However, generalized mixed methods are automatically stable, and their building process is simple and straightforward. In this paper, based on the seminal idea of the generalized mixed methods, a simple, stable, and highly accurate 8-node noncompatible symplectic element (NCSE8) was developed by the combination of the modified Hellinger-Reissner mixed variational principle and the minimum energy principle. To ensure the accuracy of in-plane stress results, a simultaneous equation approach was also suggested. Numerical experimentation shows that the accuracy of stress results of NCSE8 are nearly the same as that of displacement methods, and they are in good agreement with the exact solutions when the mesh is relatively fine. NCSE8 has advantages of the clearing concept, easy calculation by a finite element computer program, higher accuracy and wide applicability for various linear elasticity compressible and nearly incompressible material problems. It is possible that NCSE8 becomes even more advantageous for the fracture problems due to its better accuracy of stresses.

  3. Complementary-encoding holographic associative memory using a photorefractive crystal

    NASA Astrophysics Data System (ADS)

    Yuan, ShiFu; Wu, Minxian; Yan, Yingbai; Jin, Guofan

    1996-06-01

    We present a holographic implementation of accurate associative memory with only one holographic memory system. In the implementation, the stored and test images are coded by using complementary-encoding method. The recalled complete image is also a coded image that can be decoded with a decoding mask to get an original image or its complement image. The experiment shows that the complementary encoding can efficiently increase the addressing accuracy in a simple way. Instead of the above complementary-encoding method, a scheme that uses complementary area-encoding method is also proposed for the holographic implementation of gray-level image associative memory with accurate addressing.

  4. [Application of acupoint anatomy localization method with colorful tube in education of acupoint anatomy].

    PubMed

    Song, Shi-Lin

    2013-04-01

    To seek a precise and simple method for localization of acupoint in anatomical experiment teaching. Medical bone needles were inserted into acupoints. Then, self-mode copper probe needles were thrust along the center of the bone needles to open the inner structures of acuppoints. And probe needles were replaced by colored plastic tubes. Finally, bone needles were withdrawn so as to fix the plastic tubes into the acupoints to facilitate the later cutting. This method for acupoint anatomic positioning is of low cost with accurate positioning and simple manipulation, which has advantages in strong experimental and innovative values.

  5. A Simple yet Accurate Method for the Estimation of the Biovolume of Planktonic Microorganisms.

    PubMed

    Saccà, Alessandro

    2016-01-01

    Determining the biomass of microbial plankton is central to the study of fluxes of energy and materials in aquatic ecosystems. This is typically accomplished by applying proper volume-to-carbon conversion factors to group-specific abundances and biovolumes. A critical step in this approach is the accurate estimation of biovolume from two-dimensional (2D) data such as those available through conventional microscopy techniques or flow-through imaging systems. This paper describes a simple yet accurate method for the assessment of the biovolume of planktonic microorganisms, which works with any image analysis system allowing for the measurement of linear distances and the estimation of the cross sectional area of an object from a 2D digital image. The proposed method is based on Archimedes' principle about the relationship between the volume of a sphere and that of a cylinder in which the sphere is inscribed, plus a coefficient of 'unellipticity' introduced here. Validation and careful evaluation of the method are provided using a variety of approaches. The new method proved to be highly precise with all convex shapes characterised by approximate rotational symmetry, and combining it with an existing method specific for highly concave or branched shapes allows covering the great majority of cases with good reliability. Thanks to its accuracy, consistency, and low resources demand, the new method can conveniently be used in substitution of any extant method designed for convex shapes, and can readily be coupled with automated cell imaging technologies, including state-of-the-art flow-through imaging devices.

  6. A Simple yet Accurate Method for the Estimation of the Biovolume of Planktonic Microorganisms

    PubMed Central

    2016-01-01

    Determining the biomass of microbial plankton is central to the study of fluxes of energy and materials in aquatic ecosystems. This is typically accomplished by applying proper volume-to-carbon conversion factors to group-specific abundances and biovolumes. A critical step in this approach is the accurate estimation of biovolume from two-dimensional (2D) data such as those available through conventional microscopy techniques or flow-through imaging systems. This paper describes a simple yet accurate method for the assessment of the biovolume of planktonic microorganisms, which works with any image analysis system allowing for the measurement of linear distances and the estimation of the cross sectional area of an object from a 2D digital image. The proposed method is based on Archimedes’ principle about the relationship between the volume of a sphere and that of a cylinder in which the sphere is inscribed, plus a coefficient of ‘unellipticity’ introduced here. Validation and careful evaluation of the method are provided using a variety of approaches. The new method proved to be highly precise with all convex shapes characterised by approximate rotational symmetry, and combining it with an existing method specific for highly concave or branched shapes allows covering the great majority of cases with good reliability. Thanks to its accuracy, consistency, and low resources demand, the new method can conveniently be used in substitution of any extant method designed for convex shapes, and can readily be coupled with automated cell imaging technologies, including state-of-the-art flow-through imaging devices. PMID:27195667

  7. A novel method for accurate needle-tip identification in trans-rectal ultrasound-based high-dose-rate prostate brachytherapy.

    PubMed

    Zheng, Dandan; Todor, Dorin A

    2011-01-01

    In real-time trans-rectal ultrasound (TRUS)-based high-dose-rate prostate brachytherapy, the accurate identification of needle-tip position is critical for treatment planning and delivery. Currently, needle-tip identification on ultrasound images can be subject to large uncertainty and errors because of ultrasound image quality and imaging artifacts. To address this problem, we developed a method based on physical measurements with simple and practical implementation to improve the accuracy and robustness of needle-tip identification. Our method uses measurements of the residual needle length and an off-line pre-established coordinate transformation factor, to calculate the needle-tip position on the TRUS images. The transformation factor was established through a one-time systematic set of measurements of the probe and template holder positions, applicable to all patients. To compare the accuracy and robustness of the proposed method and the conventional method (ultrasound detection), based on the gold-standard X-ray fluoroscopy, extensive measurements were conducted in water and gel phantoms. In water phantom, our method showed an average tip-detection accuracy of 0.7 mm compared with 1.6 mm of the conventional method. In gel phantom (more realistic and tissue-like), our method maintained its level of accuracy while the uncertainty of the conventional method was 3.4mm on average with maximum values of over 10mm because of imaging artifacts. A novel method based on simple physical measurements was developed to accurately detect the needle-tip position for TRUS-based high-dose-rate prostate brachytherapy. The method demonstrated much improved accuracy and robustness over the conventional method. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  8. A simple differential steady-state method to measure the thermal conductivity of solid bulk materials with high accuracy.

    PubMed

    Kraemer, D; Chen, G

    2014-02-01

    Accurate measurements of thermal conductivity are of great importance for materials research and development. Steady-state methods determine thermal conductivity directly from the proportionality between heat flow and an applied temperature difference (Fourier Law). Although theoretically simple, in practice, achieving high accuracies with steady-state methods is challenging and requires rather complex experimental setups due to temperature sensor uncertainties and parasitic heat loss. We developed a simple differential steady-state method in which the sample is mounted between an electric heater and a temperature-controlled heat sink. Our method calibrates for parasitic heat losses from the electric heater during the measurement by maintaining a constant heater temperature close to the environmental temperature while varying the heat sink temperature. This enables a large signal-to-noise ratio which permits accurate measurements of samples with small thermal conductance values without an additional heater calibration measurement or sophisticated heater guards to eliminate parasitic heater losses. Additionally, the differential nature of the method largely eliminates the uncertainties of the temperature sensors, permitting measurements with small temperature differences, which is advantageous for samples with high thermal conductance values and/or with strongly temperature-dependent thermal conductivities. In order to accelerate measurements of more than one sample, the proposed method allows for measuring several samples consecutively at each temperature measurement point without adding significant error. We demonstrate the method by performing thermal conductivity measurements on commercial bulk thermoelectric Bi2Te3 samples in the temperature range of 30-150 °C with an error below 3%.

  9. Method for Accurately Calibrating a Spectrometer Using Broadband Light

    NASA Technical Reports Server (NTRS)

    Simmons, Stephen; Youngquist, Robert

    2011-01-01

    A novel method has been developed for performing very fine calibration of a spectrometer. This process is particularly useful for modern miniature charge-coupled device (CCD) spectrometers where a typical factory wavelength calibration has been performed and a finer, more accurate calibration is desired. Typically, the factory calibration is done with a spectral line source that generates light at known wavelengths, allowing specific pixels in the CCD array to be assigned wavelength values. This method is good to about 1 nm across the spectrometer s wavelength range. This new method appears to be accurate to about 0.1 nm, a factor of ten improvement. White light is passed through an unbalanced Michelson interferometer, producing an optical signal with significant spectral variation. A simple theory can be developed to describe this spectral pattern, so by comparing the actual spectrometer output against this predicted pattern, errors in the wavelength assignment made by the spectrometer can be determined.

  10. Tau-independent Phase Analysis: A Novel Method for Accurately Determining Phase Shifts.

    PubMed

    Tackenberg, Michael C; Jones, Jeff R; Page, Terry L; Hughey, Jacob J

    2018-06-01

    Estimations of period and phase are essential in circadian biology. While many techniques exist for estimating period, comparatively few methods are available for estimating phase. Current approaches to analyzing phase often vary between studies and are sensitive to coincident changes in period and the stage of the circadian cycle at which the stimulus occurs. Here we propose a new technique, tau-independent phase analysis (TIPA), for quantifying phase shifts in multiple types of circadian time-course data. Through comprehensive simulations, we show that TIPA is both more accurate and more precise than the standard actogram approach. TIPA is computationally simple and therefore will enable accurate and reproducible quantification of phase shifts across multiple subfields of chronobiology.

  11. A case report on the remodelling technique for the earlobe using a soft splint.

    PubMed

    Vaiude, Partha N; Anthony, Edwin T; Syed, Mobin; Ilyas, Syed

    2008-01-01

    Correcting earlobe deformities often presents an aesthetic challenge to the surgeon. The described technique presents a simple, accurate and cost effective method of remodelling soft tissue defects of the earlobe using a soft splint.

  12. CASE STUDIES EXAMINING LCA STREAMLINING TECHNIQUES

    EPA Science Inventory

    Pressure is mounting for more streamlined Life Cycle Assessment (LCA) methods that allow for evaluations that are quick and simple, but accurate. As part of an overall research effort to develop and demonstrate streamlined LCA, the U.S. Environmental Protection Agency has funded ...

  13. A simple video-based timing system for on-ice team testing in ice hockey: a technical report.

    PubMed

    Larson, David P; Noonan, Benjamin C

    2014-09-01

    The purpose of this study was to describe and evaluate a newly developed on-ice timing system for team evaluation in the sport of ice hockey. We hypothesized that this new, simple, inexpensive, timing system would prove to be highly accurate and reliable. Six adult subjects (age 30.4 ± 6.2 years) performed on ice tests of acceleration and conditioning. The performance times of the subjects were recorded using a handheld stopwatch, photocell, and high-speed (240 frames per second) video. These results were then compared to allow for accuracy calculations of the stopwatch and video as compared with filtered photocell timing that was used as the "gold standard." Accuracy was evaluated using maximal differences, typical error/coefficient of variation (CV), and intraclass correlation coefficients (ICCs) between the timing methods. The reliability of the video method was evaluated using the same variables in a test-retest analysis both within and between evaluators. The video timing method proved to be both highly accurate (ICC: 0.96-0.99 and CV: 0.1-0.6% as compared with the photocell method) and reliable (ICC and CV within and between evaluators: 0.99 and 0.08%, respectively). This video-based timing method provides a very rapid means of collecting a high volume of very accurate and reliable on-ice measures of skating speed and conditioning, and can easily be adapted to other testing surfaces and parameters.

  14. Machine learning predictions of molecular properties: Accurate many-body potentials and nonlocality in chemical space

    DOE PAGES

    Hansen, Katja; Biegler, Franziska; Ramakrishnan, Raghunathan; ...

    2015-06-04

    Simultaneously accurate and efficient prediction of molecular properties throughout chemical compound space is a critical ingredient toward rational compound design in chemical and pharmaceutical industries. Aiming toward this goal, we develop and apply a systematic hierarchy of efficient empirical methods to estimate atomization and total energies of molecules. These methods range from a simple sum over atoms, to addition of bond energies, to pairwise interatomic force fields, reaching to the more sophisticated machine learning approaches that are capable of describing collective interactions between many atoms or bonds. In the case of equilibrium molecular geometries, even simple pairwise force fields demonstratemore » prediction accuracy comparable to benchmark energies calculated using density functional theory with hybrid exchange-correlation functionals; however, accounting for the collective many-body interactions proves to be essential for approaching the “holy grail” of chemical accuracy of 1 kcal/mol for both equilibrium and out-of-equilibrium geometries. This remarkable accuracy is achieved by a vectorized representation of molecules (so-called Bag of Bonds model) that exhibits strong nonlocality in chemical space. The same representation allows us to predict accurate electronic properties of molecules, such as their polarizability and molecular frontier orbital energies.« less

  15. Machine Learning Predictions of Molecular Properties: Accurate Many-Body Potentials and Nonlocality in Chemical Space

    PubMed Central

    2015-01-01

    Simultaneously accurate and efficient prediction of molecular properties throughout chemical compound space is a critical ingredient toward rational compound design in chemical and pharmaceutical industries. Aiming toward this goal, we develop and apply a systematic hierarchy of efficient empirical methods to estimate atomization and total energies of molecules. These methods range from a simple sum over atoms, to addition of bond energies, to pairwise interatomic force fields, reaching to the more sophisticated machine learning approaches that are capable of describing collective interactions between many atoms or bonds. In the case of equilibrium molecular geometries, even simple pairwise force fields demonstrate prediction accuracy comparable to benchmark energies calculated using density functional theory with hybrid exchange-correlation functionals; however, accounting for the collective many-body interactions proves to be essential for approaching the “holy grail” of chemical accuracy of 1 kcal/mol for both equilibrium and out-of-equilibrium geometries. This remarkable accuracy is achieved by a vectorized representation of molecules (so-called Bag of Bonds model) that exhibits strong nonlocality in chemical space. In addition, the same representation allows us to predict accurate electronic properties of molecules, such as their polarizability and molecular frontier orbital energies. PMID:26113956

  16. Zinc Biosorption by Seaweed Illustrated by the Zincon Colorimetric Method and the Langmuir Isotherm

    ERIC Educational Resources Information Center

    Areco, Maria Mar; dos Santos Afonso, Maria; Valdman, Erika

    2007-01-01

    An experiment is conducted to promote biotechnology knowledge that is an emerging technology on cleaning treatment, showing the potential of seaweed to remove heavy-metal ions from solution. The rapid and accurate determination of zinc in aqueous solution by the zincon colorimetric method gives an interesting and simple experiment for any…

  17. On simulating flow with multiple time scales using a method of averages

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Margolin, L.G.

    1997-12-31

    The author presents a new computational method based on averaging to efficiently simulate certain systems with multiple time scales. He first develops the method in a simple one-dimensional setting and employs linear stability analysis to demonstrate numerical stability. He then extends the method to multidimensional fluid flow. His method of averages does not depend on explicit splitting of the equations nor on modal decomposition. Rather he combines low order and high order algorithms in a generalized predictor-corrector framework. He illustrates the methodology in the context of a shallow fluid approximation to an ocean basin circulation. He finds that his newmore » method reproduces the accuracy of a fully explicit second-order accurate scheme, while costing less than a first-order accurate scheme.« less

  18. Combinational Reasoning of Quantitative Fuzzy Topological Relations for Simple Fuzzy Regions

    PubMed Central

    Liu, Bo; Li, Dajun; Xia, Yuanping; Ruan, Jian; Xu, Lili; Wu, Huanyi

    2015-01-01

    In recent years, formalization and reasoning of topological relations have become a hot topic as a means to generate knowledge about the relations between spatial objects at the conceptual and geometrical levels. These mechanisms have been widely used in spatial data query, spatial data mining, evaluation of equivalence and similarity in a spatial scene, as well as for consistency assessment of the topological relations of multi-resolution spatial databases. The concept of computational fuzzy topological space is applied to simple fuzzy regions to efficiently and more accurately solve fuzzy topological relations. Thus, extending the existing research and improving upon the previous work, this paper presents a new method to describe fuzzy topological relations between simple spatial regions in Geographic Information Sciences (GIS) and Artificial Intelligence (AI). Firstly, we propose a new definition for simple fuzzy line segments and simple fuzzy regions based on the computational fuzzy topology. And then, based on the new definitions, we also propose a new combinational reasoning method to compute the topological relations between simple fuzzy regions, moreover, this study has discovered that there are (1) 23 different topological relations between a simple crisp region and a simple fuzzy region; (2) 152 different topological relations between two simple fuzzy regions. In the end, we have discussed some examples to demonstrate the validity of the new method, through comparisons with existing fuzzy models, we showed that the proposed method can compute more than the existing models, as it is more expressive than the existing fuzzy models. PMID:25775452

  19. Simple Approaches for Measuring Dry Atmospheric Nitrogen Deposition to Watersheds

    EPA Science Inventory

    Assessing the effects of atmospheric nitrogen (N) deposition on surface water quality requires accurate accounts of total N deposition (wet, dry, and cloud vapor); however, dry deposition is difficult to measure and is often spatially variable. Affordable passive sampling methods...

  20. Determination of Caffeine in Beverages by High Performance Liquid Chromatography.

    ERIC Educational Resources Information Center

    DiNunzio, James E.

    1985-01-01

    Describes the equipment, procedures, and results for the determination of caffeine in beverages by high performance liquid chromatography. The method is simple, fast, accurate, and, because sample preparation is minimal, it is well suited for use in a teaching laboratory. (JN)

  1. Accurate reporting of adherence to inhaled therapies in adults with cystic fibrosis: methods to calculate “normative adherence”

    PubMed Central

    Hoo, Zhe Hui; Curley, Rachael; Campbell, Michael J; Walters, Stephen J; Hind, Daniel; Wildman, Martin J

    2016-01-01

    Background Preventative inhaled treatments in cystic fibrosis will only be effective in maintaining lung health if used appropriately. An accurate adherence index should therefore reflect treatment effectiveness, but the standard method of reporting adherence, that is, as a percentage of the agreed regimen between clinicians and people with cystic fibrosis, does not account for the appropriateness of the treatment regimen. We describe two different indices of inhaled therapy adherence for adults with cystic fibrosis which take into account effectiveness, that is, “simple” and “sophisticated” normative adherence. Methods to calculate normative adherence Denominator adjustment involves fixing a minimum appropriate value based on the recommended therapy given a person’s characteristics. For simple normative adherence, the denominator is determined by the person’s Pseudomonas status. For sophisticated normative adherence, the denominator is determined by the person’s Pseudomonas status and history of pulmonary exacerbations over the previous year. Numerator adjustment involves capping the daily maximum inhaled therapy use at 100% so that medication overuse does not artificially inflate the adherence level. Three illustrative cases Case A is an example of inhaled therapy under prescription based on Pseudomonas status resulting in lower simple normative adherence compared to unadjusted adherence. Case B is an example of inhaled therapy under-prescription based on previous exacerbation history resulting in lower sophisticated normative adherence compared to unadjusted adherence and simple normative adherence. Case C is an example of nebulizer overuse exaggerating the magnitude of unadjusted adherence. Conclusion Different methods of reporting adherence can result in different magnitudes of adherence. We have proposed two methods of standardizing the calculation of adherence which should better reflect treatment effectiveness. The value of these indices can be tested empirically in clinical trials in which there is careful definition of treatment regimens related to key patient characteristics, alongside accurate measurement of health outcomes. PMID:27284242

  2. A spectral dynamic stiffness method for free vibration analysis of plane elastodynamic problems

    NASA Astrophysics Data System (ADS)

    Liu, X.; Banerjee, J. R.

    2017-03-01

    A highly efficient and accurate analytical spectral dynamic stiffness (SDS) method for modal analysis of plane elastodynamic problems based on both plane stress and plane strain assumptions is presented in this paper. First, the general solution satisfying the governing differential equation exactly is derived by applying two types of one-dimensional modified Fourier series. Then the SDS matrix for an element is formulated symbolically using the general solution. The SDS matrices are assembled directly in a similar way to that of the finite element method, demonstrating the method's capability to model complex structures. Any arbitrary boundary conditions are represented accurately in the form of the modified Fourier series. The Wittrick-Williams algorithm is then used as the solution technique where the mode count problem (J0) of a fully-clamped element is resolved. The proposed method gives highly accurate solutions with remarkable computational efficiency, covering low, medium and high frequency ranges. The method is applied to both plane stress and plane strain problems with simple as well as complex geometries. All results from the theory in this paper are accurate up to the last figures quoted to serve as benchmarks.

  3. A new background subtraction method for Western blot densitometry band quantification through image analysis software.

    PubMed

    Gallo-Oller, Gabriel; Ordoñez, Raquel; Dotor, Javier

    2018-06-01

    Since its first description, Western blot has been widely used in molecular labs. It constitutes a multistep method that allows the detection and/or quantification of proteins from simple to complex protein mixtures. Western blot quantification method constitutes a critical step in order to obtain accurate and reproducible results. Due to the technical knowledge required for densitometry analysis together with the resources availability, standard office scanners are often used for the imaging acquisition of developed Western blot films. Furthermore, the use of semi-quantitative software as ImageJ (Java-based image-processing and analysis software) is clearly increasing in different scientific fields. In this work, we describe the use of office scanner coupled with the ImageJ software together with a new image background subtraction method for accurate Western blot quantification. The proposed method represents an affordable, accurate and reproducible approximation that could be used in the presence of limited resources availability. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. An Integrated Fuselage-Sting Balance for a Sonic-Boom Wind-Tunnel Model

    NASA Technical Reports Server (NTRS)

    Mack, Robert J.

    2004-01-01

    Measured and predicted pressure signatures from a lifting wind-tunnel model can be compared when the lift on the model is accurately known. The model's lift can be set by bending the support sting to a desired angle of attack. This method is simple in practice, but difficult to accurately apply. A second method is to build a normal force/pitching moment balance into the aft end of the sting, and use an angle-of-attack mechanism to set model attitude. In this report, a method for designing a sting/balance into the aft fuselage/sting of a sonic-boom model is described. A computer code is given, and a sample sting design is outlined to demonstrate the method.

  5. CAD-based Automatic Modeling Method for Geant4 geometry model Through MCAM

    NASA Astrophysics Data System (ADS)

    Wang, Dong; Nie, Fanzhi; Wang, Guozhong; Long, Pengcheng; LV, Zhongliang; LV, Zhongliang

    2014-06-01

    Geant4 is a widely used Monte Carlo transport simulation package. Before calculating using Geant4, the calculation model need be established which could be described by using Geometry Description Markup Language (GDML) or C++ language. However, it is time-consuming and error-prone to manually describe the models by GDML. Automatic modeling methods have been developed recently, but there are some problem existed in most of present modeling programs, specially some of them were not accurate or adapted to specifically CAD format. To convert the GDML format models to CAD format accurately, a Geant4 Computer Aided Design (CAD) based modeling method was developed for automatically converting complex CAD geometry model into GDML geometry model. The essence of this method was dealing with CAD model represented with boundary representation (B-REP) and GDML model represented with constructive solid geometry (CSG). At first, CAD model was decomposed to several simple solids which had only one close shell. And then the simple solid was decomposed to convex shell set. Then corresponding GDML convex basic solids were generated by the boundary surfaces getting from the topological characteristic of a convex shell. After the generation of these solids, GDML model was accomplished with series boolean operations. This method was adopted in CAD/Image-based Automatic Modeling Program for Neutronics & Radiation Transport (MCAM), and tested with several models including the examples in Geant4 install package. The results showed that this method could convert standard CAD model accurately, and can be used for Geant4 automatic modeling.

  6. A simple method for correcting spatially resolved solar intensity oscillation observations for variations in scattered light

    NASA Technical Reports Server (NTRS)

    Jefferies, S. M.; Duvall, T. L., Jr.

    1991-01-01

    A measurement of the intensity distribution in an image of the solar disk will be corrupted by a spatial redistribution of the light that is caused by the earth's atmosphere and the observing instrument. A simple correction method is introduced here that is applicable for solar p-mode intensity observations obtained over a period of time in which there is a significant change in the scattering component of the point spread function. The method circumvents the problems incurred with an accurate determination of the spatial point spread function and its subsequent deconvolution from the observations. The method only corrects the spherical harmonic coefficients that represent the spatial frequencies present in the image and does not correct the image itself.

  7. External validation of a simple clinical tool used to predict falls in people with Parkinson disease

    PubMed Central

    Duncan, Ryan P.; Cavanaugh, James T.; Earhart, Gammon M.; Ellis, Terry D.; Ford, Matthew P.; Foreman, K. Bo; Leddy, Abigail L.; Paul, Serene S.; Canning, Colleen G.; Thackeray, Anne; Dibble, Leland E.

    2015-01-01

    Background Assessment of fall risk in an individual with Parkinson disease (PD) is a critical yet often time consuming component of patient care. Recently a simple clinical prediction tool based only on fall history in the previous year, freezing of gait in the past month, and gait velocity <1.1 m/s was developed and accurately predicted future falls in a sample of individuals with PD. METHODS We sought to externally validate the utility of the tool by administering it to a different cohort of 171 individuals with PD. Falls were monitored prospectively for 6 months following predictor assessment. RESULTS The tool accurately discriminated future fallers from non-fallers (area under the curve [AUC] = 0.83; 95% CI 0.76 –0.89), comparable to the developmental study. CONCLUSION The results validated the utility of the tool for allowing clinicians to quickly and accurately identify an individual’s risk of an impending fall. PMID:26003412

  8. A simple formula for predicting claw volume of cattle.

    PubMed

    Scott, T D; Naylor, J M; Greenough, P R

    1999-11-01

    The object of this study was to develop a simple method for accurately calculating the volume of bovine claws under field conditions. The digits of 30 slaughterhouse beef cattle were examined and the following four linear measurements taken from each pair of claws: (1) the length of the dorsal surface of the claw (Toe); (2) the length of the coronary band (CorBand); (3) the length of the bearing surface (Base); and (4) the height of the claw at the abaxial groove (AbaxGr). Measurements of claw volume using a simple hydrometer were highly repeatable (r(2)= 0.999) and could be calculated from linear measurements using the formula:Claw Volume (cm(3)) = (17.192 x Base) + (7.467 x AbaxGr) + 45.270 x (CorBand) - 798.5This formula was found to be accurate (r(2)= 0.88) when compared to volume data derived from a hydrometer displacement procedure. The front claws occupied 54% of the total volume compared to 46% for the hind claws. Copyright 1999 Harcourt Publishers Ltd.

  9. Passive acoustic monitoring of bed load for fluvial applications

    USDA-ARS?s Scientific Manuscript database

    The sediment transported as bed load in streams and rivers is notoriously difficult to monitor cheaply and accurately. Passive acoustic methods are relatively simple, inexpensive, and provide spatial integration along with high temporal resolution. In 1963 work began on monitoring emissions from par...

  10. The 'double headed slug flap': a simple technique to reconstruct large helical rim defects.

    PubMed

    Masud, D; Tzafetta, K

    2012-10-01

    Reconstructing partial defects of the ear can be challenging, balancing the creation of the details of the ear with scarring, morbidity and number of surgical stages. Common causes of ear defects are human bites, tumour excision and burn injuries. Reconstructing defects of the ear with tube pedicled flaps and other local flaps requires an accurate measurement of size of the defect with little room for error, particularly under estimation. We present a simple method of reconstruction for partial defects of the ear using a two-stage technique with post auricular transposition flaps. This allows for under or over estimation of size defects permitting accurate tissue usage giving good aesthetic outcomes. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Improving Prediction Accuracy for WSN Data Reduction by Applying Multivariate Spatio-Temporal Correlation

    PubMed Central

    Carvalho, Carlos; Gomes, Danielo G.; Agoulmine, Nazim; de Souza, José Neuman

    2011-01-01

    This paper proposes a method based on multivariate spatial and temporal correlation to improve prediction accuracy in data reduction for Wireless Sensor Networks (WSN). Prediction of data not sent to the sink node is a technique used to save energy in WSNs by reducing the amount of data traffic. However, it may not be very accurate. Simulations were made involving simple linear regression and multiple linear regression functions to assess the performance of the proposed method. The results show a higher correlation between gathered inputs when compared to time, which is an independent variable widely used for prediction and forecasting. Prediction accuracy is lower when simple linear regression is used, whereas multiple linear regression is the most accurate one. In addition to that, our proposal outperforms some current solutions by about 50% in humidity prediction and 21% in light prediction. To the best of our knowledge, we believe that we are probably the first to address prediction based on multivariate correlation for WSN data reduction. PMID:22346626

  12. Development of a new flux splitting scheme

    NASA Technical Reports Server (NTRS)

    Liou, Meng-Sing; Steffen, Christopher J., Jr.

    1991-01-01

    The use of a new splitting scheme, the advection upstream splitting method, for model aerodynamic problems where Van Leer and Roe schemes had failed previously is discussed. The present scheme is based on splitting in which the convective and pressure terms are separated and treated differently depending on the underlying physical conditions. The present method is found to be both simple and accurate.

  13. Development of a new flux splitting scheme

    NASA Technical Reports Server (NTRS)

    Liou, Meng-Sing; Steffen, Christopher J., Jr.

    1991-01-01

    The successful use of a novel splitting scheme, the advection upstream splitting method, for model aerodynamic problems where Van Leer and Roe schemes had failed previously is discussed. The present scheme is based on splitting in which the convective and pressure terms are separated and treated differently depending on the underlying physical conditions. The present method is found to be both simple and accurate.

  14. Which Method Is Most Precise; Which Is Most Accurate? An Undergraduate Experiment

    ERIC Educational Resources Information Center

    Jordan, A. D.

    2007-01-01

    A simple experiment, the determination of the density of a liquid by several methods, is presented. Since the concept of density is a familiar one, the experiment is suitable for the introductory laboratory period of a first- or second-year course in physical or analytical chemistry. The main objective of the experiment is to familiarize students…

  15. Review of Thawing Time Prediction Models Depending
on Process Conditions and Product Characteristics

    PubMed Central

    Kluza, Franciszek; Spiess, Walter E. L.; Kozłowicz, Katarzyna

    2016-01-01

    Summary Determining thawing times of frozen foods is a challenging problem as the thermophysical properties of the product change during thawing. A number of calculation models and solutions have been developed. The proposed solutions range from relatively simple analytical equations based on a number of assumptions to a group of empirical approaches that sometimes require complex calculations. In this paper analytical, empirical and graphical models are presented and critically reviewed. The conditions of solution, limitations and possible applications of the models are discussed. The graphical and semi--graphical models are derived from numerical methods. Using the numerical methods is not always possible as running calculations takes time, whereas the specialized software and equipment are not always cheap. For these reasons, the application of analytical-empirical models is more useful for engineering. It is demonstrated that there is no simple, accurate and feasible analytical method for thawing time prediction. Consequently, simplified methods are needed for thawing time estimation of agricultural and food products. The review reveals the need for further improvement of the existing solutions or development of new ones that will enable accurate determination of thawing time within a wide range of practical conditions of heat transfer during processing. PMID:27904387

  16. Multi-atlas segmentation enables robust multi-contrast MRI spleen segmentation for splenomegaly

    NASA Astrophysics Data System (ADS)

    Huo, Yuankai; Liu, Jiaqi; Xu, Zhoubing; Harrigan, Robert L.; Assad, Albert; Abramson, Richard G.; Landman, Bennett A.

    2017-02-01

    Non-invasive spleen volume estimation is essential in detecting splenomegaly. Magnetic resonance imaging (MRI) has been used to facilitate splenomegaly diagnosis in vivo. However, achieving accurate spleen volume estimation from MR images is challenging given the great inter-subject variance of human abdomens and wide variety of clinical images/modalities. Multi-atlas segmentation has been shown to be a promising approach to handle heterogeneous data and difficult anatomical scenarios. In this paper, we propose to use multi-atlas segmentation frameworks for MRI spleen segmentation for splenomegaly. To the best of our knowledge, this is the first work that integrates multi-atlas segmentation for splenomegaly as seen on MRI. To address the particular concerns of spleen MRI, automated and novel semi-automated atlas selection approaches are introduced. The automated approach interactively selects a subset of atlases using selective and iterative method for performance level estimation (SIMPLE) approach. To further control the outliers, semi-automated craniocaudal length based SIMPLE atlas selection (L-SIMPLE) is proposed to introduce a spatial prior in a fashion to guide the iterative atlas selection. A dataset from a clinical trial containing 55 MRI volumes (28 T1 weighted and 27 T2 weighted) was used to evaluate different methods. Both automated and semi-automated methods achieved median DSC > 0.9. The outliers were alleviated by the L-SIMPLE (≍1 min manual efforts per scan), which achieved 0.9713 Pearson correlation compared with the manual segmentation. The results demonstrated that the multi-atlas segmentation is able to achieve accurate spleen segmentation from the multi-contrast splenomegaly MRI scans.

  17. Multi-atlas Segmentation Enables Robust Multi-contrast MRI Spleen Segmentation for Splenomegaly.

    PubMed

    Huo, Yuankai; Liu, Jiaqi; Xu, Zhoubing; Harrigan, Robert L; Assad, Albert; Abramson, Richard G; Landman, Bennett A

    2017-02-11

    Non-invasive spleen volume estimation is essential in detecting splenomegaly. Magnetic resonance imaging (MRI) has been used to facilitate splenomegaly diagnosis in vivo. However, achieving accurate spleen volume estimation from MR images is challenging given the great inter-subject variance of human abdomens and wide variety of clinical images/modalities. Multi-atlas segmentation has been shown to be a promising approach to handle heterogeneous data and difficult anatomical scenarios. In this paper, we propose to use multi-atlas segmentation frameworks for MRI spleen segmentation for splenomegaly. To the best of our knowledge, this is the first work that integrates multi-atlas segmentation for splenomegaly as seen on MRI. To address the particular concerns of spleen MRI, automated and novel semi-automated atlas selection approaches are introduced. The automated approach interactively selects a subset of atlases using selective and iterative method for performance level estimation (SIMPLE) approach. To further control the outliers, semi-automated craniocaudal length based SIMPLE atlas selection (L-SIMPLE) is proposed to introduce a spatial prior in a fashion to guide the iterative atlas selection. A dataset from a clinical trial containing 55 MRI volumes (28 T1 weighted and 27 T2 weighted) was used to evaluate different methods. Both automated and semi-automated methods achieved median DSC > 0.9. The outliers were alleviated by the L-SIMPLE (≈1 min manual efforts per scan), which achieved 0.9713 Pearson correlation compared with the manual segmentation. The results demonstrated that the multi-atlas segmentation is able to achieve accurate spleen segmentation from the multi-contrast splenomegaly MRI scans.

  18. Improved Design Formulae for Buckling of Orthotropic Plates under Combined Loading

    NASA Technical Reports Server (NTRS)

    Weaver, Paul M.; Nemeth, Michael P.

    2008-01-01

    Simple, accurate buckling interaction formulae are presented for long orthotropic plates with either simply supported or clamped longitudinal edges and under combined loading that are suitable for design studies. The loads include 1) combined uniaxial compression (or tension) and shear, 2) combined pure inplane bending and 3) shear and combined uniaxial compression (or tension) and pure inplane bending. The interaction formulae are the results of detailed regression analysis of buckling data obtained from a very accurate Rayleigh-Ritz method.

  19. Measuring g Using a Magnetic Pendulum and Telephone Pickup

    NASA Astrophysics Data System (ADS)

    Sinacore, J.; Takai, H.

    2010-10-01

    The simple pendulum has long been used to measure g, the acceleration due to gravity, with a precision of a few percent. Achieving agreement with the accepted value of less than 1% is feasible in the high school laboratory, though it requires some care. The precision of the measurement is bound by how accurately the period and the pendulum length are determined. To improve on the period measurement, we have developed a simple and inexpensive method using a magnet and telephone pickup.2

  20. A method for determining the composition of methanol-trimethyl borate mixtures

    NASA Technical Reports Server (NTRS)

    Kaye, Samuel; Sordyl, Frank

    1955-01-01

    A study of mixtures of pure methanol and trimethyl borate showed that the composition can be accurately obtained by a simple density determination. The refractive-index determination gives the composition with much less accuracy. The potentiometric titration of boric acid is also discussed.

  1. Determination of the cement content of hardened concrete by selective solution : final report.

    DOT National Transportation Integrated Search

    1972-01-01

    The method of selective solution by methanolic maleic acid, developed by Tabikh et. al for the determination of cement content in hardened concrete, was evaluated. It was found to be relatively simple and inexpensive, and is accurate to within 1 pe...

  2. Numerical Differentiation of Noisy, Nonsmooth Data

    DOE PAGES

    Chartrand, Rick

    2011-01-01

    We consider the problem of differentiating a function specified by noisy data. Regularizing the differentiation process avoids the noise amplification of finite-difference methods. We use total-variation regularization, which allows for discontinuous solutions. The resulting simple algorithm accurately differentiates noisy functions, including those which have a discontinuous derivative.

  3. Sexing the Sciuridae: a simple and accurate set of molecular methods to determine sex in tree squirrels, ground squirrels and marmots.

    PubMed

    Gorrell, Jamieson C; Boutin, Stan; Raveh, Shirley; Neuhaus, Peter; Côté, Steeve D; Coltman, David W

    2012-09-01

    We determined the sequence of the male-specific minor histocompatibility complex antigen (Smcy) from the Y chromosome of seven squirrel species (Sciuridae, Rodentia). Based on conserved regions inside the Smcy intron sequence, we designed PCR primers for sex determination in these species that can be co-amplified with nuclear loci as controls. PCR co-amplification yields two products for males and one for females that are easily visualized as bands by agarose gel electrophoresis. Our method provides simple and reliable sex determination across a wide range of squirrel species. © 2012 Blackwell Publishing Ltd.

  4. Accurate Estimate of Some Propagation Characteristics for the First Higher Order Mode in Graded Index Fiber with Simple Analytic Chebyshev Method

    NASA Astrophysics Data System (ADS)

    Dutta, Ivy; Chowdhury, Anirban Roy; Kumbhakar, Dharmadas

    2013-03-01

    Using Chebyshev power series approach, accurate description for the first higher order (LP11) mode of graded index fibers having three different profile shape functions are presented in this paper and applied to predict their propagation characteristics. These characteristics include fractional power guided through the core, excitation efficiency and Petermann I and II spot sizes with their approximate analytic formulations. We have shown that where two and three Chebyshev points in LP11 mode approximation present fairly accurate results, the values based on our calculations involving four Chebyshev points match excellently with available exact numerical results.

  5. The use of National Weather Service Data to Compute the Dose to the MEOI.

    PubMed

    Vickers, Linda

    2018-05-01

    The Turner method is the "benchmark method" for computing the stability class that is used to compute the X/Q (s m). The Turner method should be used to ascertain the validity of X/Q results determined by other methods. This paper used site-specific meteorological data obtained from the National Weather Service. The Turner method described herein is simple, quick, accurate, and transparent because all of the data, calculations, and results are visible for verification and validation with published literature.

  6. Therapeutic Drug Monitoring of Phenytoin by Simple, Rapid, Accurate, Highly Sensitive and Novel Method and Its Clinical Applications.

    PubMed

    Shaikh, Abdul S; Guo, Ruichen

    2017-01-01

    Phenytoin has very challenging pharmacokinetic properties. To prevent its toxicity and ensure efficacy, continuous therapeutic monitoring is required. It is hard to get a simple, accurate, rapid, easily available, economical and highly sensitive assay in one method for therapeutic monitoring of phenytoin. The present study is directed towards establishing and validating a simpler, rapid, an accurate, highly sensitive, novel and environment friendly liquid chromatography/mass spectrometry (LC/MS) method for offering rapid and reliable TDM results of phenytoin in epileptic patients to physicians and clinicians for making immediate and rational decision. 27 epileptics patients with uncontrolled seizures or suspected of non-compliance or toxicity of phenytoin were selected and advised for TDM of phenytoin by neurologists of Qilu Hospital Jinan, China. The LC/MS assay was used for performing of therapeutic monitoring of phenytoin. The Agilent 1100 LC/MS system was used for TDM. The mixture of Ammonium acetate 5mM: Methanol at (35: 65 v/v) was used for the composition of mobile phase. The Diamonsil C18 (150mm×4.6mm, 5μm) column was used for the extraction of analytes in plasma. The samples were prepared with one step simple protein precipitation method. The technique was validated with the guidelines of International Conference on Harmonisation (ICH). The calibration curve demonstrated decent linearity within (0.2-20 µg/mL) concentration range with linearity equation, y= 0.0667855 x +0.00241785 and correlation coefficient (R2) of 0.99928. The specificity, recovery, linearity, accuracy, precision and stability results were within the accepted limits. The concentration of 0.2 µg/mL was observed as lower limit of quantitation (LLOQ), which is 12.5 times lower than the currently available enzyme-multiplied immunoassay technique (EMIT) for measurement of phenytoin in epilepsy patients. A rapid, simple, economical, precise, highly sensitive and novel LC/MS assay has been established, validated and applied successfully in TDM of 27 epileptics patients. It was alarmingly found that TDM results of all these patients were out of safe range except two patients. However, it needs further evaluation. Besides TDM, the stated method can also be applied in bioequivalence, pharmacokinetics, toxicokinetics and pharmacovigilance studies. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  7. Simple gas chromatographic method for furfural analysis.

    PubMed

    Gaspar, Elvira M S M; Lopes, João F

    2009-04-03

    A new, simple, gas chromatographic method was developed for the direct analysis of 5-hydroxymethylfurfural (5-HMF), 2-furfural (2-F) and 5-methylfurfural (5-MF) in liquid and water soluble foods, using direct immersion SPME coupled to GC-FID and/or GC-TOF-MS. The fiber (DVB/CAR/PDMS) conditions were optimized: pH effect, temperature, adsorption and desorption times. The method is simple and accurate (RSD<8%), showed good recoveries (77-107%) and good limits of detection (GC-FID: 1.37 microgL(-1) for 2-F, 8.96 microgL(-1) for 5-MF, 6.52 microgL(-1) for 5-HMF; GC-TOF-MS: 0.3, 1.2 and 0.9 ngmL(-1) for 2-F, 5-MF and 5-HMF, respectively). It was applied to different commercial food matrices: honey, white, demerara, brown and yellow table sugars, and white and red balsamic vinegars. This one-step, sensitive and direct method for the analysis of furfurals will contribute to characterise and quantify their presence in the human diet.

  8. Protein detection by Simple Western™ analysis.

    PubMed

    Harris, Valerie M

    2015-01-01

    Protein Simple© has taken a well-known protein detection method, the western blot, and revolutionized it. The Simple Western™ system uses capillary electrophoresis to identify and quantitate a protein of interest. Protein Simple© provides multiple detection apparatuses (Wes, Sally Sue, or Peggy Sue) that are suggested to save scientists valuable time by allowing the researcher to prepare the protein sample, load it along with necessary antibodies and substrates, and walk away. Within 3-5 h the protein will be separated by size, or charge, immuno-detection of target protein will be accurately quantitated, and results will be immediately made available. Using the Peggy Sue instrument, one study recently examined changes in MAPK signaling proteins in the sex-determining stage of gonadal development. Here the methodology is described.

  9. A simple and accurate HPLC method for fecal bile acid profile in healthy and cirrhotic subjects: validation by GC-MS and LC-MS[S

    PubMed Central

    Kakiyama, Genta; Muto, Akina; Takei, Hajime; Nittono, Hiroshi; Murai, Tsuyoshi; Kurosawa, Takao; Hofmann, Alan F.; Pandak, William M.; Bajaj, Jasmohan S.

    2014-01-01

    We have developed a simple and accurate HPLC method for measurement of fecal bile acids using phenacyl derivatives of unconjugated bile acids, and applied it to the measurement of fecal bile acids in cirrhotic patients. The HPLC method has the following steps: 1) lyophilization of the stool sample; 2) reconstitution in buffer and enzymatic deconjugation using cholylglycine hydrolase/sulfatase; 3) incubation with 0.1 N NaOH in 50% isopropanol at 60°C to hydrolyze esterified bile acids; 4) extraction of bile acids from particulate material using 0.1 N NaOH; 5) isolation of deconjugated bile acids by solid phase extraction; 6) formation of phenacyl esters by derivatization using phenacyl bromide; and 7) HPLC separation measuring eluted peaks at 254 nm. The method was validated by showing that results obtained by HPLC agreed with those obtained by LC-MS/MS and GC-MS. We then applied the method to measuring total fecal bile acid (concentration) and bile acid profile in samples from 38 patients with cirrhosis (17 early, 21 advanced) and 10 healthy subjects. Bile acid concentrations were significantly lower in patients with advanced cirrhosis, suggesting impaired bile acid synthesis. PMID:24627129

  10. A novel diagnostic method for malaria using loop-mediated isothermal amplification (LAMP) and MinION™ nanopore sequencer.

    PubMed

    Imai, Kazuo; Tarumoto, Norihito; Misawa, Kazuhisa; Runtuwene, Lucky Ronald; Sakai, Jun; Hayashida, Kyoko; Eshita, Yuki; Maeda, Ryuichiro; Tuda, Josef; Murakami, Takashi; Maesaki, Shigefumi; Suzuki, Yutaka; Yamagishi, Junya; Maeda, Takuya

    2017-09-13

    A simple and accurate molecular diagnostic method for malaria is urgently needed due to the limitations of conventional microscopic examination. In this study, we demonstrate a new diagnostic procedure for human malaria using loop mediated isothermal amplification (LAMP) and the MinION™ nanopore sequencer. We generated specific LAMP primers targeting the 18S-rRNA gene of all five human Plasmodium species including two P. ovale subspecies (P. falciparum, P. vivax, P. ovale wallikeri, P. ovale curtisi, P. knowlesi and P. malariae) and examined human blood samples collected from 63 malaria patients in Indonesia. Additionally, we performed amplicon sequencing of our LAMP products using MinION™ nanopore sequencer to identify each Plasmodium species. Our LAMP method allowed amplification of all targeted 18S-rRNA genes of the reference plasmids with detection limits of 10-100 copies per reaction. Among the 63 clinical samples, 54 and 55 samples were positive by nested PCR and our LAMP method, respectively. Identification of the Plasmodium species by LAMP amplicon sequencing analysis using the MinION™ was consistent with the reference plasmid sequences and the results of nested PCR. Our diagnostic method combined with LAMP and MinION™ could become a simple and accurate tool for the identification of human Plasmodium species, even in resource-limited situations.

  11. New developments in the method of space-time conservation element and solution element: Applications to the Euler and Navier-Stokes equations

    NASA Technical Reports Server (NTRS)

    Chang, Sin-Chung

    1993-01-01

    A new numerical framework for solving conservation laws is being developed. This new approach differs substantially in both concept and methodology from the well-established methods--i.e., finite difference, finite volume, finite element, and spectral methods. It is conceptually simple and designed to avoid several key limitations to the above traditional methods. An explicit model scheme for solving a simple 1-D unsteady convection-diffusion equation is constructed and used to illuminate major differences between the current method and those mentioned above. Unexpectedly, its amplification factors for the pure convection and pure diffusion cases are identical to those of the Leapfrog and the DuFort-Frankel schemes, respectively. Also, this explicit scheme and its Navier-Stokes extension have the unusual property that their stabilities are limited only by the CFL condition. Moreover, despite the fact that it does not use any flux-limiter or slope-limiter, the Navier-Stokes solver is capable of generating highly accurate shock tube solutions with shock discontinuities being resolved within one mesh interval. An accurate Euler solver also is constructed through another extension. It has many unusual properties, e.g., numerical diffusion at all mesh points can be controlled by a set of local parameters.

  12. A novel method for determining sex in late term gestational mice based on the external genitalia

    PubMed Central

    Murdaugh, Laura B.; Mendoza-Romero, Haley N.; Fish, Eric W.

    2018-01-01

    In many experiments using fetal mice, it is necessary to determine the sex of the individual fetus. However, other than genotyping for sex-specific genes, there is no convenient, reliable method of sexing mice between gestational day (GD) 16.5 and GD 18.0. We designed a rapid, relatively simple visual method to determine the sex of mouse fetuses in the GD 16.5—GD 18.0 range that can be performed as part of a routine morphological assessment. By examining the genitalia for the presence or absence of key features, raters with minimal experience with the method were able to correctly identify the sex of embryos with 99% accuracy, while raters with no experience were 95% accurate. The critical genital features include: the presence or absence of urethral seam or proximal urethral meatus; the shape of the genitalia, and the presence or absence of an area related to the urethral plate. By comparing these morphological features of the external genitalia, we show a simple, accurate, and fast way to determine the sex of late stage mouse fetuses. Integrating this method into regular morphological assessments will facilitate the determination of sex differences in fetuses between GD 16.5 and GD 18.0. PMID:29617407

  13. A Simple Method for Reproducing Orbital Plots for Illustration Using Microsoft Paint and Microsoft Excel

    NASA Astrophysics Data System (ADS)

    Niebuhr, Cole

    2018-04-01

    Papers published in the astronomical community, particularly in the field of double star research, often contain plots that display the positions of the component stars relative to each other on a Cartesian coordinate plane. Due to the complexities of plotting a three-dimensional orbit into a two-dimensional image, it is often difficult to include an accurate reproduction of the orbit for comparison purposes. Methods to circumvent this obstacle do exist; however, many of these protocols result in low-quality blurred images or require specific and often expensive software. Here, a method is reported using Microsoft Paint and Microsoft Excel to produce high-quality images with an accurate reproduction of a partial orbit.

  14. An Economical Semi-Analytical Orbit Theory for Retarded Satellite Motion About an Oblate Planet

    NASA Technical Reports Server (NTRS)

    Gordon, R. A.

    1980-01-01

    Brouwer and Brouwer-Lyddanes' use of the Von Zeipel-Delaunay method is employed to develop an efficient analytical orbit theory suitable for microcomputers. A succinctly simple pseudo-phenomenologically conceptualized algorithm is introduced which accurately and economically synthesizes modeling of drag effects. The method epitomizes and manifests effortless efficient computer mechanization. Simulated trajectory data is employed to illustrate the theory's ability to accurately accommodate oblateness and drag effects for microcomputer ground based or onboard predicted orbital representation. Real tracking data is used to demonstrate that the theory's orbit determination and orbit prediction capabilities are favorably adaptable to and are comparable with results obtained utilizing complex definitive Cowell method solutions on satellites experiencing significant drag effects.

  15. Improved response functions for gamma-ray skyshine analyses

    NASA Astrophysics Data System (ADS)

    Shultis, J. K.; Faw, R. E.; Deng, X.

    1992-09-01

    A computationally simple method, based on line-beam response functions, is refined for estimating gamma skyshine dose rates. Critical to this method is the availability of an accurate approximation for the line-beam response function (LBRF). In this study, the LBRF is evaluated accurately with the point-kernel technique using recent photon interaction data. Various approximations to the LBRF are considered, and a three parameter formula is selected as the most practical approximation. By fitting the approximating formula to point-kernel results, a set of parameters is obtained that allows the LBRF to be quickly and accurately evaluated for energies between 0.01 and 15 MeV, for source-to-detector distances from 1 to 3000 m, and for beam angles from 0 to 180 degrees. This re-evaluation of the approximate LBRF gives better accuracy, especially at low energies, over a greater source-to-detector range than do previous LBRF approximations. A conical beam response function is also introduced for application to skyshine sources that are azimuthally symmetric about a vertical axis. The new response functions are then applied to three simple skyshine geometries (an open silo geometry, an infinite wall, and a rectangular four-wall building) and the results are compared to previous calculations and benchmark data.

  16. Improved response functions for gamma-ray skyshine analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shultis, J.K.; Faw, R.E.; Deng, X.

    1992-09-01

    A computationally simple method, based on line-beam response functions, is refined for estimating gamma skyshine dose rates. Critical to this method is the availability of an accurate approximation for the line-beam response function (LBRF). In this study the LBRF is evaluated accurately with the point-kernel technique using recent photon interaction data. Various approximations to the LBRF are considered, and a three parameter formula is selected as the most practical approximation. By fitting the approximating formula to point-kernel results, a set of parameters is obtained that allows the LBRF to be quickly and accurately evaluated for energies between 0.01 and 15more » MeV, for source-to-detector distances from 1 to 3000 m, and for beam angles from 0 to 180 degrees. This reevaluation of the approximate LBRF gives better accuracy, especially at low energies, over a greater source-to-detector range than do previous LBRF approximations. A conical beam response function is also introduced for application to skyshine sources that are azimuthally symmetric about a vertical axis. The new response functions are then applied to three simple skyshine geometries (an open silo geometry, an infinite wall, and a rectangular four-wall building) and the results compared to previous calculations and benchmark data.« less

  17. Use of iPhone technology in improving acetabular component position in total hip arthroplasty.

    PubMed

    Tay, Xiau Wei; Zhang, Benny Xu; Gayagay, George

    2017-09-01

    Improper acetabular cup positioning is associated with high risk of complications after total hip arthroplasty. The aim of our study is to objectively compare 3 methods, namely (1) free hand, (2) alignment jig (Sputnik), and (3) iPhone application to identify an easy, reproducible, and accurate method in improving acetabular cup placement. We designed a simple setup and carried out a simple experiment (see Method section). Using statistical analysis, the difference in inclination angles using iPhone application compared with the freehand method was found to be statistically significant ( F [2,51] = 4.17, P = .02) in the "untrained group". There is no statistical significance detected for the other groups. This suggests a potential role for iPhone applications in junior surgeons in overcoming the steep learning curve.

  18. Methods for estimating 2D cloud size distributions from 1D observations

    DOE PAGES

    Romps, David M.; Vogelmann, Andrew M.

    2017-08-04

    The two-dimensional (2D) size distribution of clouds in the horizontal plane plays a central role in the calculation of cloud cover, cloud radiative forcing, convective entrainment rates, and the likelihood of precipitation. Here, a simple method is proposed for calculating the area-weighted mean cloud size and for approximating the 2D size distribution from the 1D cloud chord lengths measured by aircraft and vertically pointing lidar and radar. This simple method (which is exact for square clouds) compares favorably against the inverse Abel transform (which is exact for circular clouds) in the context of theoretical size distributions. Both methods also performmore » well when used to predict the size distribution of real clouds from a Landsat scene. When applied to a large number of Landsat scenes, the simple method is able to accurately estimate the mean cloud size. Finally, as a demonstration, the methods are applied to aircraft measurements of shallow cumuli during the RACORO campaign, which then allow for an estimate of the true area-weighted mean cloud size.« less

  19. Methods for estimating 2D cloud size distributions from 1D observations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romps, David M.; Vogelmann, Andrew M.

    The two-dimensional (2D) size distribution of clouds in the horizontal plane plays a central role in the calculation of cloud cover, cloud radiative forcing, convective entrainment rates, and the likelihood of precipitation. Here, a simple method is proposed for calculating the area-weighted mean cloud size and for approximating the 2D size distribution from the 1D cloud chord lengths measured by aircraft and vertically pointing lidar and radar. This simple method (which is exact for square clouds) compares favorably against the inverse Abel transform (which is exact for circular clouds) in the context of theoretical size distributions. Both methods also performmore » well when used to predict the size distribution of real clouds from a Landsat scene. When applied to a large number of Landsat scenes, the simple method is able to accurately estimate the mean cloud size. Finally, as a demonstration, the methods are applied to aircraft measurements of shallow cumuli during the RACORO campaign, which then allow for an estimate of the true area-weighted mean cloud size.« less

  20. Keeping It Simple: Can We Estimate Malting Quality Potential Using an Isothermal Mashing Protocol and Common Laboratory Instrumentation?

    USDA-ARS?s Scientific Manuscript database

    Current methods for generating malting quality metrics have been developed largely to support commercial malting and brewing operations, providing accurate, reproducible analytical data to guide malting and brewing production. Infrastructure to support these analytical operations often involves sub...

  1. Oxygen transfer rate estimation in oxidation ditches from clean water measurements.

    PubMed

    Abusam, A; Keesman, K J; Meinema, K; Van Straten, G

    2001-06-01

    Standard methods for the determination of oxygen transfer rate are based on assumptions that are not valid for oxidation ditches. This paper presents a realistic and simple new method to be used in the estimation of oxygen transfer rate in oxidation ditches from clean water measurements. The new method uses a loop-of-CSTRs model, which can be easily incorporated within control algorithms, for modelling oxidation ditches. Further, this method assumes zero oxygen transfer rates (KLa) in the unaerated CSTRs. Application of a formal estimation procedure to real data revealed that the aeration constant (k = KLaVA, where VA is the volume of the aerated CSTR) can be determined significantly more accurately than KLa and VA. Therefore, the new method estimates k instead of KLa. From application to real data, this method proved to be more accurate than the commonly used Dutch standard method (STORA, 1980).

  2. Daniell method for power spectral density estimation in atomic force microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Labuda, Aleksander

    An alternative method for power spectral density (PSD) estimation—the Daniell method—is revisited and compared to the most prevalent method used in the field of atomic force microscopy for quantifying cantilever thermal motion—the Bartlett method. Both methods are shown to underestimate the Q factor of a simple harmonic oscillator (SHO) by a predictable, and therefore correctable, amount in the absence of spurious deterministic noise sources. However, the Bartlett method is much more prone to spectral leakage which can obscure the thermal spectrum in the presence of deterministic noise. By the significant reduction in spectral leakage, the Daniell method leads to amore » more accurate representation of the true PSD and enables clear identification and rejection of deterministic noise peaks. This benefit is especially valuable for the development of automated PSD fitting algorithms for robust and accurate estimation of SHO parameters from a thermal spectrum.« less

  3. Light Field Imaging Based Accurate Image Specular Highlight Removal

    PubMed Central

    Wang, Haoqian; Xu, Chenxue; Wang, Xingzheng; Zhang, Yongbing; Peng, Bo

    2016-01-01

    Specular reflection removal is indispensable to many computer vision tasks. However, most existing methods fail or degrade in complex real scenarios for their individual drawbacks. Benefiting from the light field imaging technology, this paper proposes a novel and accurate approach to remove specularity and improve image quality. We first capture images with specularity by the light field camera (Lytro ILLUM). After accurately estimating the image depth, a simple and concise threshold strategy is adopted to cluster the specular pixels into “unsaturated” and “saturated” category. Finally, a color variance analysis of multiple views and a local color refinement are individually conducted on the two categories to recover diffuse color information. Experimental evaluation by comparison with existed methods based on our light field dataset together with Stanford light field archive verifies the effectiveness of our proposed algorithm. PMID:27253083

  4. A simple and inexpensive method for muddy shore profiling

    NASA Astrophysics Data System (ADS)

    Chowdhury, Sayedur Rahman; Hossain, M. Shahadat; Sharifuzzaman, S. M.

    2014-11-01

    There are several well-established methods for obtaining beach profiles, and more accurate and precise high-tech methods are emerging. Traditional low-cost methods requiring minimal user skill or training are still popular among professionals, scientists, and coastal zone management practitioners. Simple methods are being developed with a primary focus on sand and gravel beaches. This paper describes a simple, low-cost, manual field method for measuring profiles of beaches, which is particularly suitable for muddy shores. The equipment is a type of flexible U-tube manometer that uses liquid columns in vertical tubes to measure differences in elevation; the supporting frame is constructed from wooden poles with base disks, which hold measuring scales and a PVC tube. The structure was trialed on a mudflat characterized by a 20-40-cm-thick surface layer of silt and clay, located at the Kutubdia Island, Bangladesh. The study results are discussed with notes on the method's applicability, advantages and limitations, and several optional modifications for different scenarios for routine profiling of muddy shores. The equipment can be used by one person or two people, and the accuracy of the method is comparable to those in other methods. The equipment can also be used on sandy or gravel beaches.

  5. Development of a simple fluorescence-based microplate method for the high-throughput analysis of proline in wine samples.

    PubMed

    Robert-Peillard, Fabien; Boudenne, Jean-Luc; Coulomb, Bruno

    2014-05-01

    This paper presents a simple, accurate and multi-sample method for the determination of proline in wines thanks to a 96-well microplate technique. Proline is the most abundant amino acid in wine and is an important parameter related to wine characteristics or maturation processes of grape. In the current study, an improved application of the general method based on sodium hypochlorite oxidation and o-phthaldialdehyde (OPA)-thiol spectrofluorometric detection is described. The main interfering compounds for specific proline detection in wines are strongly reduced by selective reaction with OPA in a preliminary step under well-defined pH conditions. Application of the protocol after a 500-fold dilution of wine samples provides a working range between 0.02 and 2.90gL(-1), with a limit of detection of 7.50mgL(-1). Comparison and validation on real wine samples by ion-exchange chromatography prove that this procedure yields accurate results. Simplicity of the protocol used, with no need for centrifugation or filtration, organic solvents or high temperature enables its full implementation in plastic microplates and efficient application for routine analysis of proline in wines. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Spectrophotometric simultaneous determination of Rabeprazole Sodium and Itopride Hydrochloride in capsule dosage form

    NASA Astrophysics Data System (ADS)

    Sabnis, Shweta S.; Dhavale, Nilesh D.; Jadhav, Vijay. Y.; Gandhi, Santosh V.

    2008-03-01

    A new simple, economical, rapid, precise and accurate method for simultaneous determination of rabeprazole sodium and itopride hydrochloride in capsule dosage form has been developed. The method is based on ratio spectra derivative spectrophotometry. The amplitudes in the first derivative of the corresponding ratio spectra at 231 nm (minima) and 260 nm were selected to determine rabeprazole sodium and itopride hydrochloride, respectively. The method was validated with respect to linearity, precision and accuracy.

  7. Spectrophotometric simultaneous determination of rabeprazole sodium and itopride hydrochloride in capsule dosage form.

    PubMed

    Sabnis, Shweta S; Dhavale, Nilesh D; Jadhav, Vijay Y; Gandhi, Santosh V

    2008-03-01

    A new simple, economical, rapid, precise and accurate method for simultaneous determination of rabeprazole sodium and itopride hydrochloride in capsule dosage form has been developed. The method is based on ratio spectra derivative spectrophotometry. The amplitudes in the first derivative of the corresponding ratio spectra at 231nm (minima) and 260nm were selected to determine rabeprazole sodium and itopride hydrochloride, respectively. The method was validated with respect to linearity, precision and accuracy.

  8. Age estimation standards for a Western Australian population using the coronal pulp cavity index.

    PubMed

    Karkhanis, Shalmira; Mack, Peter; Franklin, Daniel

    2013-09-10

    Age estimation is a vital aspect in creating a biological profile and aids investigators by narrowing down potentially matching identities from the available pool. In addition to routine casework, in the present global political scenario, age estimation in living individuals is required in cases of refugees, asylum seekers, human trafficking and to ascertain age of criminal responsibility. Thus robust methods that are simple, non-invasive and ethically viable are required. The aim of the present study is, therefore, to test the reliability and applicability of the coronal pulp cavity index method, for the purpose of developing age estimation standards for an adult Western Australian population. A total of 450 orthopantomograms (220 females and 230 males) of Australian individuals were analyzed. Crown and coronal pulp chamber heights were measured in the mandibular left and right premolars, and the first and second molars. These measurements were then used to calculate the tooth coronal index. Data was analyzed using paired sample t-tests to assess bilateral asymmetry followed by simple linear and multiple regressions to develop age estimation models. The most accurate age estimation based on simple linear regression model was with mandibular right first molar (SEE ±8.271 years). Multiple regression models improved age prediction accuracy considerably and the most accurate model was with bilateral first and second molars (SEE ±6.692 years). This study represents the first investigation of this method in a Western Australian population and our results indicate that the method is suitable for forensic application. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Simple, sensitive, selective and validated spectrophotometric methods for the estimation of a biomarker trigonelline from polyherbal gels

    NASA Astrophysics Data System (ADS)

    Chopra, Shruti; Motwani, Sanjay K.; Ahmad, Farhan J.; Khar, Roop K.

    2007-11-01

    Simple, accurate, reproducible, selective, sensitive and cost effective UV-spectrophotometric methods were developed and validated for the estimation of trigonelline in bulk and pharmaceutical formulations. Trigonelline was estimated at 265 nm in deionised water and at 264 nm in phosphate buffer (pH 4.5). Beer's law was obeyed in the concentration ranges of 1-20 μg mL -1 ( r2 = 0.9999) in deionised water and 1-24 μg mL -1 ( r2 = 0.9999) in the phosphate buffer medium. The apparent molar absorptivity and Sandell's sensitivity coefficient were found to be 4.04 × 10 3 L mol -1 cm -1 and 0.0422 μg cm -2/0.001A in deionised water; and 3.05 × 10 3 L mol -1 cm -1 and 0.0567 μg cm -2/0.001A in phosphate buffer media, respectively. These methods were tested and validated for various parameters according to ICH guidelines. The detection and quantitation limits were found to be 0.12 and 0.37 μg mL -1 in deionised water and 0.13 and 0.40 μg mL -1 in phosphate buffer medium, respectively. The proposed methods were successfully applied for the determination of trigonelline in pharmaceutical formulations (vaginal tablets and bioadhesive vaginal gels). The results demonstrated that the procedure is accurate, precise, specific and reproducible (percent relative standard deviation <2%), while being simple and less time consuming and hence can be suitably applied for the estimation of trigonelline in different dosage forms and dissolution studies.

  10. A Cartesian cut cell method for rarefied flow simulations around moving obstacles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dechristé, G., E-mail: Guillaume.Dechriste@math.u-bordeaux1.fr; CNRS, IMB, UMR 5251, F-33400 Talence; Mieussens, L., E-mail: Luc.Mieussens@math.u-bordeaux1.fr

    2016-06-01

    For accurate simulations of rarefied gas flows around moving obstacles, we propose a cut cell method on Cartesian grids: it allows exact conservation and accurate treatment of boundary conditions. Our approach is designed to treat Cartesian cells and various kinds of cut cells by the same algorithm, with no need to identify the specific shape of each cut cell. This makes the implementation quite simple, and allows a direct extension to 3D problems. Such simulations are also made possible by using an adaptive mesh refinement technique and a hybrid parallel implementation. This is illustrated by several test cases, including amore » 3D unsteady simulation of the Crookes radiometer.« less

  11. Estimating Model Probabilities using Thermodynamic Markov Chain Monte Carlo Methods

    NASA Astrophysics Data System (ADS)

    Ye, M.; Liu, P.; Beerli, P.; Lu, D.; Hill, M. C.

    2014-12-01

    Markov chain Monte Carlo (MCMC) methods are widely used to evaluate model probability for quantifying model uncertainty. In a general procedure, MCMC simulations are first conducted for each individual model, and MCMC parameter samples are then used to approximate marginal likelihood of the model by calculating the geometric mean of the joint likelihood of the model and its parameters. It has been found the method of evaluating geometric mean suffers from the numerical problem of low convergence rate. A simple test case shows that even millions of MCMC samples are insufficient to yield accurate estimation of the marginal likelihood. To resolve this problem, a thermodynamic method is used to have multiple MCMC runs with different values of a heating coefficient between zero and one. When the heating coefficient is zero, the MCMC run is equivalent to a random walk MC in the prior parameter space; when the heating coefficient is one, the MCMC run is the conventional one. For a simple case with analytical form of the marginal likelihood, the thermodynamic method yields more accurate estimate than the method of using geometric mean. This is also demonstrated for a case of groundwater modeling with consideration of four alternative models postulated based on different conceptualization of a confining layer. This groundwater example shows that model probabilities estimated using the thermodynamic method are more reasonable than those obtained using the geometric method. The thermodynamic method is general, and can be used for a wide range of environmental problem for model uncertainty quantification.

  12. A simple accurate chest-compression depth gauge using magnetic coils during cardiopulmonary resuscitation

    NASA Astrophysics Data System (ADS)

    Kandori, Akihiko; Sano, Yuko; Zhang, Yuhua; Tsuji, Toshio

    2015-12-01

    This paper describes a new method for calculating chest compression depth and a simple chest-compression gauge for validating the accuracy of the method. The chest-compression gauge has two plates incorporating two magnetic coils, a spring, and an accelerometer. The coils are located at both ends of the spring, and the accelerometer is set on the bottom plate. Waveforms obtained using the magnetic coils (hereafter, "magnetic waveforms"), which are proportional to compression-force waveforms and the acceleration waveforms were measured at the same time. The weight factor expressing the relationship between the second derivatives of the magnetic waveforms and the measured acceleration waveforms was calculated. An estimated-compression-displacement (depth) waveform was obtained by multiplying the weight factor and the magnetic waveforms. Displacements of two large springs (with similar spring constants) within a thorax and displacements of a cardiopulmonary resuscitation training manikin were measured using the gauge to validate the accuracy of the calculated waveform. A laser-displacement detection system was used to compare the real displacement waveform and the estimated waveform. Intraclass correlation coefficients (ICCs) between the real displacement using the laser system and the estimated displacement waveforms were calculated. The estimated displacement error of the compression depth was within 2 mm (<1 standard deviation). All ICCs (two springs and a manikin) were above 0.85 (0.99 in the case of one of the springs). The developed simple chest-compression gauge, based on a new calculation method, provides an accurate compression depth (estimation error < 2 mm).

  13. Laser light-scattering spectroscopy: a new application in the study of ciliary activity.

    PubMed Central

    Lee, W I; Verdugo, P

    1976-01-01

    A uniquely precise and simple method to study ciliary activity by laser light-scattering spectroscopy has been developed and validated. A concurrent study of the effect of Ca2+ on ciliary activity in vitro by laser scattering spectroscopy and high speed cinematography has demonstrated that this new method is simpler and as accurate and reproducible as the high speed film technique. PMID:963208

  14. Standardized methods for photography in procedural dermatology using simple equipment.

    PubMed

    Hexsel, Doris; Hexsel, Camile L; Dal'Forno, Taciana; Schilling de Souza, Juliana; Silva, Aline F; Siega, Carolina

    2017-04-01

    Photography is an important tool in dermatology. Reproducing the settings of before photos after interventions allows more accurate evaluation of treatment outcomes. In this article, we describe standardized methods and tips to obtain photographs, both for clinical practice and research procedural dermatology, using common equipment. Standards for the studio, cameras, photographer, patients, and framing are presented in this article. © 2017 The International Society of Dermatology.

  15. Electrochemistry and analytical determination of lysergic acid diethylamide (LSD) via adsorptive stripping voltammetry.

    PubMed

    Merli, Daniele; Zamboni, Daniele; Protti, Stefano; Pesavento, Maria; Profumo, Antonella

    2014-12-01

    Lysergic acid diethylamide (LSD) is hardly detectable and quantifiable in biological samples because of its low active dose. Although several analytical tests are available, routine analysis of this drug is rarely performed. In this article, we report a simple and accurate method for the determination of LSD, based on adsorptive stripping voltammetry in DMF/tetrabutylammonium perchlorate, with a linear range of 1-90 ng L(-1) for deposition times of 50s. LOD of 1.4 ng L(-1) and LOQ of 4.3 ng L(-1) were found. The method can be also applied to biological samples after a simple extraction with 1-chlorobutane. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Robot geometry calibration

    NASA Technical Reports Server (NTRS)

    Hayati, Samad; Tso, Kam; Roston, Gerald

    1988-01-01

    Autonomous robot task execution requires that the end effector of the robot be positioned accurately relative to a reference world-coordinate frame. The authors present a complete formulation to identify the actual robot geometric parameters. The method applies to any serial link manipulator with arbitrary order and combination of revolute and prismatic joints. A method is also presented to solve the inverse kinematic of the actual robot model which usually is not a so-called simple robot. Experimental results performed by utilizing a PUMA 560 with simple measurement hardware are presented. As a result of this calibration a precision move command is designed and integrated into a robot language, RCCL, and used in the NASA Telerobot Testbed.

  17. Development of a simple chromatographic method for the determination of piracetam in human plasma and its pharmacokinetic evaluation.

    PubMed

    Barkat, K; Ahmad, M; Minhas, M U; Malik, M Z; Sohail, M

    2014-07-01

    The objective of study was to develop an accurate and reproducible HPLC method for determination of piracetam in human plasma and to evaluate pharmacokinetic parameters of 800 mg piracetam. A simple, rapid, accurate, precise and sensitive high pressure liquid chromatography method has been developed and subsequently validated for determination of piracetam. This study represents the results of a randomized, single-dose and single-period in 18 healthy male volunteers to assess pharmacokinetic parameters of 800 mg piracetam tablets. Various pharmacokinetic parameters were determined from plasma for piracetam and found to be in good agreement with previous reported values. The data was analyzed by using Kinetica® version 4.4 according to non-compartment model of pharmacokinetic analysis and after comparison with previous studies, no significant differences were found in present study of tested product. The major pharmacokinetic parameters for piracetam were as follows: t1/2 was (4.40 ± 0.179) h; Tmax value was (2.33 ± 0.105) h; Cmax was (14.53 ± 0.282) µg/mL; the AUC(0-∞) was (59.19 ± 4.402) µg · h/mL. AUMC(0-∞) was (367.23 ± 38.96) µg. (h)(2)/mL; Ke was (0.16 ± 0.006) h; MRT was (5.80 ± 0.227) h; Vd was (96.36 ± 8.917 L). A rapid, accurate and precise high pressure liquid chromatography method was developed and validated before the study. It is concluded that this method is very useful for the analysis of pharmacokinetic parameters, in human plasma and assured the safety and efficacy of piracetam, can be effectively used in medical practice. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Reverse radiance: a fast accurate method for determining luminance

    NASA Astrophysics Data System (ADS)

    Moore, Kenneth E.; Rykowski, Ronald F.; Gangadhara, Sanjay

    2012-10-01

    Reverse ray tracing from a region of interest backward to the source has long been proposed as an efficient method of determining luminous flux. The idea is to trace rays only from where the final flux needs to be known back to the source, rather than tracing in the forward direction from the source outward to see where the light goes. Once the reverse ray reaches the source, the radiance the equivalent forward ray would have represented is determined and the resulting flux computed. Although reverse ray tracing is conceptually simple, the method critically depends upon an accurate source model in both the near and far field. An overly simplified source model, such as an ideal Lambertian surface substantially detracts from the accuracy and thus benefit of the method. This paper will introduce an improved method of reverse ray tracing that we call Reverse Radiance that avoids assumptions about the source properties. The new method uses measured data from a Source Imaging Goniometer (SIG) that simultaneously measures near and far field luminous data. Incorporating this data into a fast reverse ray tracing integration method yields fast, accurate data for a wide variety of illumination problems.

  19. Fast and Accurate Circuit Design Automation through Hierarchical Model Switching.

    PubMed

    Huynh, Linh; Tagkopoulos, Ilias

    2015-08-21

    In computer-aided biological design, the trifecta of characterized part libraries, accurate models and optimal design parameters is crucial for producing reliable designs. As the number of parts and model complexity increase, however, it becomes exponentially more difficult for any optimization method to search the solution space, hence creating a trade-off that hampers efficient design. To address this issue, we present a hierarchical computer-aided design architecture that uses a two-step approach for biological design. First, a simple model of low computational complexity is used to predict circuit behavior and assess candidate circuit branches through branch-and-bound methods. Then, a complex, nonlinear circuit model is used for a fine-grained search of the reduced solution space, thus achieving more accurate results. Evaluation with a benchmark of 11 circuits and a library of 102 experimental designs with known characterization parameters demonstrates a speed-up of 3 orders of magnitude when compared to other design methods that provide optimality guarantees.

  20. Homodyne chiral polarimetry for measuring thermo-optic refractive index variations.

    PubMed

    Twu, Ruey-Ching; Wang, Jhao-Sheng

    2015-10-10

    Novel reflection-type homodyne chiral polarimetry is proposed for measuring the refractive index variations of a transparent plate under thermal impact. The experimental results show it is a simple and useful method for providing accurate measurements of refractive index variations. The measurement can reach a resolution of 7×10-5.

  1. High Precision Method of Measuring the Velocity of Sound With Simple Apparatus

    ERIC Educational Resources Information Center

    Hansen, Russell C.

    1975-01-01

    A capacitor is discharged to generate an acoustical pulse and start a digital counter which is stopped by a microphone. Differences are accurately measured by positioning the sensing microphone on an optical bench. Results are discussed and extended experiments are suggested. The sources of some components are given. (GH)

  2. A simple, accurate, field-portable mixing ratio generator and Rayleigh distillation device

    USDA-ARS?s Scientific Manuscript database

    Routine field calibration of water vapor analyzers has always been a challenging problem for those making long-term flux measurements at remote sites. Automated sampling of standard gases from compressed tanks, the method of choice for CO2 calibration, cannot be used for H2O. Calibrations are typica...

  3. On the use of video projectors for three-dimensional scanning

    NASA Astrophysics Data System (ADS)

    Juarez-Salazar, Rigoberto; Diaz-Ramirez, Victor H.; Robledo-Sanchez, Carlos; Diaz-Gonzalez, Gerardo

    2017-08-01

    Structured light projection is one of the most useful methods for accurate three-dimensional scanning. Video projectors are typically used as the illumination source. However, because video projectors are not designed for structured light systems, some considerations such as gamma calibration must be taken into account. In this work, we present a simple method for gamma calibration of video projectors. First, the experimental fringe patterns are normalized. Then, the samples of the fringe patterns are sorted in ascending order. The sample sorting leads to a simple three-parameter sine curve that is fitted using the Gauss-Newton algorithm. The novelty of this method is that the sorting process removes the effect of the unknown phase. Thus, the resulting gamma calibration algorithm is significantly simplified. The feasibility of the proposed method is illustrated in a three-dimensional scanning experiment.

  4. Selection of actuator locations for static shape control of large space structures by heuristic integer programing

    NASA Technical Reports Server (NTRS)

    Haftka, R. T.; Adelman, H. M.

    1984-01-01

    Orbiting spacecraft such as large space antennas have to maintain a highly accurate space to operate satisfactorily. Such structures require active and passive controls to mantain an accurate shape under a variety of disturbances. Methods for the optimum placement of control actuators for correcting static deformations are described. In particular, attention is focused on the case were control locations have to be selected from a large set of available sites, so that integer programing methods are called for. The effectiveness of three heuristic techniques for obtaining a near-optimal site selection is compared. In addition, efficient reanalysis techniques for the rapid assessment of control effectiveness are presented. Two examples are used to demonstrate the methods: a simple beam structure and a 55m space-truss-parabolic antenna.

  5. Highly Accurate Analytical Approximate Solution to a Nonlinear Pseudo-Oscillator

    NASA Astrophysics Data System (ADS)

    Wu, Baisheng; Liu, Weijia; Lim, C. W.

    2017-07-01

    A second-order Newton method is presented to construct analytical approximate solutions to a nonlinear pseudo-oscillator in which the restoring force is inversely proportional to the dependent variable. The nonlinear equation is first expressed in a specific form, and it is then solved in two steps, a predictor and a corrector step. In each step, the harmonic balance method is used in an appropriate manner to obtain a set of linear algebraic equations. With only one simple second-order Newton iteration step, a short, explicit, and highly accurate analytical approximate solution can be derived. The approximate solutions are valid for all amplitudes of the pseudo-oscillator. Furthermore, the method incorporates second-order Taylor expansion in a natural way, and it is of significant faster convergence rate.

  6. Speeding up GW Calculations to Meet the Challenge of Large Scale Quasiparticle Predictions.

    PubMed

    Gao, Weiwei; Xia, Weiyi; Gao, Xiang; Zhang, Peihong

    2016-11-11

    Although the GW approximation is recognized as one of the most accurate theories for predicting materials excited states properties, scaling up conventional GW calculations for large systems remains a major challenge. We present a powerful and simple-to-implement method that can drastically accelerate fully converged GW calculations for large systems, enabling fast and accurate quasiparticle calculations for complex materials systems. We demonstrate the performance of this new method by presenting the results for ZnO and MgO supercells. A speed-up factor of nearly two orders of magnitude is achieved for a system containing 256 atoms (1024 valence electrons) with a negligibly small numerical error of ±0.03 eV. Finally, we discuss the application of our method to the GW calculations for 2D materials.

  7. Reconstructing Spatial Distributions from Anonymized Locations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Horey, James L; Forrest, Stephanie; Groat, Michael

    2012-01-01

    Devices such as mobile phones, tablets, and sensors are often equipped with GPS that accurately report a person's location. Combined with wireless communication, these devices enable a wide range of new social tools and applications. These same qualities, however, leave location-aware applications vulnerable to privacy violations. This paper introduces the Negative Quad Tree, a privacy protection method for location aware applications. The method is broadly applicable to applications that use spatial density information, such as social applications that measure the popularity of social venues. The method employs a simple anonymization algorithm running on mobile devices, and a more complex reconstructionmore » algorithm on a central server. This strategy is well suited to low-powered mobile devices. The paper analyzes the accuracy of the reconstruction method in a variety of simulated and real-world settings and demonstrates that the method is accurate enough to be used in many real-world scenarios.« less

  8. SLTCAP: A Simple Method for Calculating the Number of Ions Needed for MD Simulation.

    PubMed

    Schmit, Jeremy D; Kariyawasam, Nilusha L; Needham, Vince; Smith, Paul E

    2018-04-10

    An accurate depiction of electrostatic interactions in molecular dynamics requires the correct number of ions in the simulation box to capture screening effects. However, the number of ions that should be added to the box is seldom given by the bulk salt concentration because a charged biomolecule solute will perturb the local solvent environment. We present a simple method for calculating the number of ions that requires only the total solute charge, solvent volume, and bulk salt concentration as inputs. We show that the most commonly used method for adding salt to a simulation results in an effective salt concentration that is too high. These findings are confirmed using simulations of lysozyme. We have established a web server where these calculations can be readily performed to aid simulation setup.

  9. Comparison of different approaches of modelling in a masonry building

    NASA Astrophysics Data System (ADS)

    Saba, M.; Meloni, D.

    2017-12-01

    The present work has the objective to model a simple masonry building, through two different modelling methods in order to assess their validity in terms of evaluation of static stresses. Have been chosen two of the most commercial software used to address this kind of problem, which are of S.T.A. Data S.r.l. and Sismicad12 of Concrete S.r.l. While the 3Muri software adopts the Frame by Macro Elements Method (FME), which should be more schematic and more efficient, Sismicad12 software uses the Finite Element Method (FEM), which guarantees accurate results, with greater computational burden. Remarkably differences of the static stresses, for such a simple structure between the two approaches have been found, and an interesting comparison and analysis of the reasons is proposed.

  10. Simultaneous Determination of Potassium Clavulanate and Amoxicillin Trihydrate in Bulk, Pharmaceutical Formulations and in Human Urine Samples by UV Spectrophotometry

    PubMed Central

    Gujral, Rajinder Singh; Haque, Sk Manirul

    2010-01-01

    A simple and sensitive UV spectrophotometric method was developed and validated for the simultaneous determination of Potassium Clavulanate (PC) and Amoxicillin Trihydrate (AT) in bulk, pharmaceutical formulations and in human urine samples. The method was linear in the range of 0.2–8.5 μg/ml for PC and 6.4–33.6 μg/ml for AT. The absorbance was measured at 205 and 271 nm for PC and AT respectively. The method was validated with respect to accuracy, precision, specificity, ruggedness, robustness, limit of detection and limit of quantitation. This method was used successfully for the quality assessment of four PC and AT drug products and in human urine samples with good precision and accuracy. This is found to be simple, specific, precise, accurate, reproducible and low cost UV Spectrophotometric method. PMID:23675211

  11. Method for Constructing Composite Response Surfaces by Combining Neural Networks with Polynominal Interpolation or Estimation Techniques

    NASA Technical Reports Server (NTRS)

    Rai, Man Mohan (Inventor); Madavan, Nateri K. (Inventor)

    2007-01-01

    A method and system for data modeling that incorporates the advantages of both traditional response surface methodology (RSM) and neural networks is disclosed. The invention partitions the parameters into a first set of s simple parameters, where observable data are expressible as low order polynomials, and c complex parameters that reflect more complicated variation of the observed data. Variation of the data with the simple parameters is modeled using polynomials; and variation of the data with the complex parameters at each vertex is analyzed using a neural network. Variations with the simple parameters and with the complex parameters are expressed using a first sequence of shape functions and a second sequence of neural network functions. The first and second sequences are multiplicatively combined to form a composite response surface, dependent upon the parameter values, that can be used to identify an accurate mode

  12. Transmitted wavefront testing with large dynamic range based on computer-aided deflectometry

    NASA Astrophysics Data System (ADS)

    Wang, Daodang; Xu, Ping; Gong, Zhidong; Xie, Zhongmin; Liang, Rongguang; Xu, Xinke; Kong, Ming; Zhao, Jun

    2018-06-01

    The transmitted wavefront testing technique is demanded for the performance evaluation of transmission optics and transparent glass, in which the achievable dynamic range is a key issue. A computer-aided deflectometric testing method with fringe projection is proposed for the accurate testing of transmitted wavefronts with a large dynamic range. Ray tracing of the modeled testing system is carried out to achieve the virtual ‘null’ testing of transmitted wavefront aberrations. The ray aberration is obtained from the ray tracing result and measured slope, with which the test wavefront aberration can be reconstructed. To eliminate testing system modeling errors, a system geometry calibration based on computer-aided reverse optimization is applied to realize accurate testing. Both numerical simulation and experiments have been carried out to demonstrate the feasibility and high accuracy of the proposed testing method. The proposed testing method can achieve a large dynamic range compared with the interferometric method, providing a simple, low-cost and accurate way for the testing of transmitted wavefronts from various kinds of optics and a large amount of industrial transmission elements.

  13. A computer program for the localization of small areas in roentgenological images

    NASA Technical Reports Server (NTRS)

    Keller, R. A.; Baily, N. A.

    1976-01-01

    A method and associated algorithm are presented which allow a simple and accurate determination to be made of the location of small symmetric areas presented in roentgenological images. The method utilizes an operator to visually spot object positions but eliminates the need for critical positioning accuracy on the operator's part. The rapidity of measurement allows results to be evaluated on-line. Parameters associated with the algorithm have been analyzed, and methods to facilitate an optimum choice for any particular experimental setup are presented.

  14. Synapse fits neuron: joint reduction by model inversion.

    PubMed

    van der Scheer, H T; Doelman, A

    2017-08-01

    In this paper, we introduce a novel simplification method for dealing with physical systems that can be thought to consist of two subsystems connected in series, such as a neuron and a synapse. The aim of our method is to help find a simple, yet convincing model of the full cascade-connected system, assuming that a satisfactory model of one of the subsystems, e.g., the neuron, is already given. Our method allows us to validate a candidate model of the full cascade against data at a finer scale. In our main example, we apply our method to part of the squid's giant fiber system. We first postulate a simple, hypothetical model of cell-to-cell signaling based on the squid's escape response. Then, given a FitzHugh-type neuron model, we derive the verifiable model of the squid giant synapse that this hypothesis implies. We show that the derived synapse model accurately reproduces synaptic recordings, hence lending support to the postulated, simple model of cell-to-cell signaling, which thus, in turn, can be used as a basic building block for network models.

  15. Stability indicating methods for the analysis of cefprozil in the presence of its alkaline induced degradation product

    NASA Astrophysics Data System (ADS)

    Attia, Khalid A. M.; Nassar, Mohammed W. I.; El-Zeiny, Mohamed B.; Serag, Ahmed

    2016-04-01

    Three simple, specific, accurate and precise spectrophotometric methods were developed for the determination of cefprozil (CZ) in the presence of its alkaline induced degradation product (DCZ). The first method was the bivariate method, while the two other multivariate methods were partial least squares (PLS) and spectral residual augmented classical least squares (SRACLS). The multivariate methods were applied with and without variable selection procedure (genetic algorithm GA). These methods were tested by analyzing laboratory prepared mixtures of the above drug with its alkaline induced degradation product and they were applied to its commercial pharmaceutical products.

  16. A Simple Method for Assessing Upper-Limb Force-Velocity Profile in Bench Press.

    PubMed

    Rahmani, Abderrahmane; Samozino, Pierre; Morin, Jean-Benoit; Morel, Baptiste

    2018-02-01

    To analyze the reliability and validity of a field computation method based on easy-to-measure data to assess the mean force ([Formula: see text]) and velocity ([Formula: see text]) produced during a ballistic bench-press movement and to verify that the force-velocity profile (F-v) obtained with multiple loaded trials is accurately described. Twelve participants performed ballistic bench presses against various lifted mass from 30% to 70% of their body mass. For each trial, [Formula: see text] and [Formula: see text] were determined from an accelerometer (sampling rate 500 Hz; reference method) and a simple computation method based on upper-limb mass, barbell flight height, and push-off distance. These [Formula: see text] and [Formula: see text] data were used to establish the F-v relationship for each individual and method. A strong to almost perfect reliability was observed between the 2 trials (ICC > .90 for [Formula: see text] and .80 for [Formula: see text], CV% < 10%), whatever the considered method. The mechanical variables ([Formula: see text], [Formula: see text]) measured with the 2 methods and all the variables extrapolated from the F-v relationships were strongly correlated (r 2  > .80, P < .001). The practical differences between the methods for the extrapolated mechanical parameters were all <5%, indicating very probably no differences. The findings suggest that the simple computation method used here provides valid and reliable information on force and velocity produced during ballistic bench press, in line with that observed in laboratory conditions. This simple method is thus a practical tool, requiring only 3 simple parameters (upper-limb mass, barbell flight height, and push-off distance).

  17. Accurate Simulation of MPPT Methods Performance When Applied to Commercial Photovoltaic Panels

    PubMed Central

    2015-01-01

    A new, simple, and quick-calculation methodology to obtain a solar panel model, based on the manufacturers' datasheet, to perform MPPT simulations, is described. The method takes into account variations on the ambient conditions (sun irradiation and solar cells temperature) and allows fast MPPT methods comparison or their performance prediction when applied to a particular solar panel. The feasibility of the described methodology is checked with four different MPPT methods applied to a commercial solar panel, within a day, and under realistic ambient conditions. PMID:25874262

  18. Accurate simulation of MPPT methods performance when applied to commercial photovoltaic panels.

    PubMed

    Cubas, Javier; Pindado, Santiago; Sanz-Andrés, Ángel

    2015-01-01

    A new, simple, and quick-calculation methodology to obtain a solar panel model, based on the manufacturers' datasheet, to perform MPPT simulations, is described. The method takes into account variations on the ambient conditions (sun irradiation and solar cells temperature) and allows fast MPPT methods comparison or their performance prediction when applied to a particular solar panel. The feasibility of the described methodology is checked with four different MPPT methods applied to a commercial solar panel, within a day, and under realistic ambient conditions.

  19. Simple and accurate methods for quantifying deformation, disruption, and development in biological tissues

    PubMed Central

    Boyle, John J.; Kume, Maiko; Wyczalkowski, Matthew A.; Taber, Larry A.; Pless, Robert B.; Xia, Younan; Genin, Guy M.; Thomopoulos, Stavros

    2014-01-01

    When mechanical factors underlie growth, development, disease or healing, they often function through local regions of tissue where deformation is highly concentrated. Current optical techniques to estimate deformation can lack precision and accuracy in such regions due to challenges in distinguishing a region of concentrated deformation from an error in displacement tracking. Here, we present a simple and general technique for improving the accuracy and precision of strain estimation and an associated technique for distinguishing a concentrated deformation from a tracking error. The strain estimation technique improves accuracy relative to other state-of-the-art algorithms by directly estimating strain fields without first estimating displacements, resulting in a very simple method and low computational cost. The technique for identifying local elevation of strain enables for the first time the successful identification of the onset and consequences of local strain concentrating features such as cracks and tears in a highly strained tissue. We apply these new techniques to demonstrate a novel hypothesis in prenatal wound healing. More generally, the analytical methods we have developed provide a simple tool for quantifying the appearance and magnitude of localized deformation from a series of digital images across a broad range of disciplines. PMID:25165601

  20. Simple method for self-referenced and lable-free biosensing by using a capillary sensing element.

    PubMed

    Liu, Yun; Chen, Shimeng; Liu, Qiang; Liu, Zigeng; Wei, Peng

    2017-05-15

    We demonstrated a simple method for self-reference and label free biosensing based on a capillary sensing element and common optoelectronic devices. The capillary sensing element is illuminated by a light-emitting diode (LED) light source and detected by a webcam. Part of gold film that deposited on the tubing wall is functionalized to carry on the biological information in the excited SPR modes. The end face of the capillary was monitored and separate regions of interest (ROIs) were selected as the measurement channel and the reference channel. In the ROIs, the biological information can be accurately extracted from the image by simple image processing. Moreover, temperature fluctuation, bulk RI fluctuation, light source fluctuation and other factors can be effectively compensated during detection. Our biosensing device has a sensitivity of 1145%/RIU and a resolution better than 5.287 × 10 -4 RIU, considering a 0.79% noise level. We apply it for concanavalin A (Con A) biological measurement, which has an approximately linear response to the specific analyte concentration. This simple method provides a new approach for multichannel SPR sensing and reference-compensated calibration of SPR signal for label-free detection.

  1. Use of Machine Learning to Identify Children with Autism and Their Motor Abnormalities

    ERIC Educational Resources Information Center

    Crippa, Alessandro; Salvatore, Christian; Perego, Paolo; Forti, Sara; Nobile, Maria; Molteni, Massimo; Castiglioni, Isabella

    2015-01-01

    In the present work, we have undertaken a proof-of-concept study to determine whether a simple upper-limb movement could be useful to accurately classify low-functioning children with autism spectrum disorder (ASD) aged 2-4. To answer this question, we developed a supervised machine-learning method to correctly discriminate 15 preschool children…

  2. Comparing simple respiration models for eddy flux and dynamic chamber data

    Treesearch

    Andrew D. Richardson; Bobby H. Braswell; David Y. Hollinger; Prabir Burman; Eric A. Davidson; Robert S. Evans; Lawrence B. Flanagan; J. William Munger; Kathleen Savage; Shawn P. Urbanski; Steven C. Wofsy

    2006-01-01

    Selection of an appropriate model for respiration (R) is important for accurate gap-filling of CO2 flux data, and for partitioning measurements of net ecosystem exchange (NEE) to respiration and gross ecosystem exchange (GEE). Using cross-validation methods and a version of Akaike's Information Criterion (AIC), we evaluate a wide range of...

  3. Programmable calculator uses equation to figure steady-state gas-pipeline flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmberg, E.

    Because it is accurate and consistent over a wide range of variables, the Colebrook-White (C-W) formula serves as the basis for many methods of calculating turbulent flow in gas pipelines. Oilconsult reveals a simple way to adapt the C-W formula to calculate steady-state pipeline flow using the TI-59 programmable calculator.

  4. QUANTITATION OF MENSTRUAL BLOOD LOSS: A RADIOACTIVE METHOD UTILIZING A COUNTING DOME

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tauxe, W.N.

    A description has been given of a simple, accurate tech nique for the quantitation of menstrual blood loss, involving the determination of a three- dimensional isosensitivity curve and the fashioning of a lucite dome with cover to fit these specifications. Ten normal subjects lost no more than 50 ml each per menstrual period. (auth)

  5. Fuel moisture - a guide for evaluating severity of fire seasons

    Treesearch

    Richard J. Barney

    1964-01-01

    Field personnel in all forest fire protection agencies need some simple but reasonably accurate method for evaluating severity of the fire season as it progresses and of comparing severity of the current season with that of preceding fire seasons. This paper proposes use of records of average fuel moisture percentages cumulated continuously for 5-day periods throughout...

  6. A generalized modal shock spectra method for spacecraft loads analysis. [internal loads in a spacecraft structure subjected to a dynamic launch environment

    NASA Technical Reports Server (NTRS)

    Trubert, M.; Salama, M.

    1979-01-01

    Unlike an earlier shock spectra approach, generalization permits an accurate elastic interaction between the spacecraft and launch vehicle to obtain accurate bounds on the spacecraft response and structural loads. In addition, the modal response from a previous launch vehicle transient analysis with or without a dummy spacecraft - is exploited to define a modal impulse as a simple idealization of the actual forcing function. The idealized modal forcing function is then used to derive explicit expressions for an estimate of the bound on the spacecraft structural response and forces. Greater accuracy is achieved with the present method over the earlier shock spectra, while saving much computational effort over the transient analysis.

  7. An accurate reactive power control study in virtual flux droop control

    NASA Astrophysics Data System (ADS)

    Wang, Aimeng; Zhang, Jia

    2017-12-01

    This paper investigates the problem of reactive power sharing based on virtual flux droop method. Firstly, flux droop control method is derived, where complicated multiple feedback loops and parameter regulation are avoided. Then, the reasons for inaccurate reactive power sharing are theoretically analyzed. Further, a novel reactive power control scheme is proposed which consists of three parts: compensation control, voltage recovery control and flux droop control. Finally, the proposed reactive power control strategy is verified in a simplified microgrid model with two parallel DGs. The simulation results show that the proposed control scheme can achieve accurate reactive power sharing and zero deviation of voltage. Meanwhile, it has some advantages of simple control and excellent dynamic and static performance.

  8. Determination of molybenum in soils and rocks: A geochemical semimicro field method

    USGS Publications Warehouse

    Ward, F.N.

    1951-01-01

    Reconnaissance work in geochemical prospecting requires a simple, rapid, and moderately accurate method for the determination of small amounts of molybdenum in soils and rocks. The useful range of the suggested procedure is from 1 to 32 p.p.m. of molybdenum, but the upper limit can be extended. Duplicate determinations on eight soil samples containing less than 10 p.p.m. of molybdenum agree within 1 p.p.m., and a comparison of field results with those obtained by a conventional laboratory procedure shows that the method is sufficiently accurate for use in geochemical prospecting. The time required for analysis and the quantities of reagents needed have been decreased to provide essentially a "test tube" method for the determination of molybdenum in soils and rocks. With a minimum amount of skill, one analyst can make 30 molybdenum determinations in an 8-hour day.

  9. Accurate Bit Error Rate Calculation for Asynchronous Chaos-Based DS-CDMA over Multipath Channel

    NASA Astrophysics Data System (ADS)

    Kaddoum, Georges; Roviras, Daniel; Chargé, Pascal; Fournier-Prunaret, Daniele

    2009-12-01

    An accurate approach to compute the bit error rate expression for multiuser chaosbased DS-CDMA system is presented in this paper. For more realistic communication system a slow fading multipath channel is considered. A simple RAKE receiver structure is considered. Based on the bit energy distribution, this approach compared to others computation methods existing in literature gives accurate results with low computation charge. Perfect estimation of the channel coefficients with the associated delays and chaos synchronization is assumed. The bit error rate is derived in terms of the bit energy distribution, the number of paths, the noise variance, and the number of users. Results are illustrated by theoretical calculations and numerical simulations which point out the accuracy of our approach.

  10. A simple filter circuit for denoising biomechanical impact signals.

    PubMed

    Subramaniam, Suba R; Georgakis, Apostolos

    2009-01-01

    We present a simple scheme for denoising non-stationary biomechanical signals with the aim of accurately estimating their second derivative (acceleration). The method is based on filtering in fractional Fourier domains using well-known low-pass filters in a way that amounts to a time-varying cut-off threshold. The resulting algorithm is linear and its design is facilitated by the relationship between the fractional Fourier transform and joint time-frequency representations. The implemented filter circuit employs only three low-order filters while its efficiency is further supported by the low computational complexity of the fractional Fourier transform. The results demonstrate that the proposed method can denoise the signals effectively and is more robust against noise as compared to conventional low-pass filters.

  11. DendroBLAST: approximate phylogenetic trees in the absence of multiple sequence alignments.

    PubMed

    Kelly, Steven; Maini, Philip K

    2013-01-01

    The rapidly growing availability of genome information has created considerable demand for both fast and accurate phylogenetic inference algorithms. We present a novel method called DendroBLAST for reconstructing phylogenetic dendrograms/trees from protein sequences using BLAST. This method differs from other methods by incorporating a simple model of sequence evolution to test the effect of introducing sequence changes on the reliability of the bipartitions in the inferred tree. Using realistic simulated sequence data we demonstrate that this method produces phylogenetic trees that are more accurate than other commonly-used distance based methods though not as accurate as maximum likelihood methods from good quality multiple sequence alignments. In addition to tests on simulated data, we use DendroBLAST to generate input trees for a supertree reconstruction of the phylogeny of the Archaea. This independent analysis produces an approximate phylogeny of the Archaea that has both high precision and recall when compared to previously published analysis of the same dataset using conventional methods. Taken together these results demonstrate that approximate phylogenetic trees can be produced in the absence of multiple sequence alignments, and we propose that these trees will provide a platform for improving and informing downstream bioinformatic analysis. A web implementation of the DendroBLAST method is freely available for use at http://www.dendroblast.com/.

  12. A critical analysis of some popular methods for the discretisation of the gradient operator in finite volume methods

    NASA Astrophysics Data System (ADS)

    Syrakos, Alexandros; Varchanis, Stylianos; Dimakopoulos, Yannis; Goulas, Apostolos; Tsamopoulos, John

    2017-12-01

    Finite volume methods (FVMs) constitute a popular class of methods for the numerical simulation of fluid flows. Among the various components of these methods, the discretisation of the gradient operator has received less attention despite its fundamental importance with regards to the accuracy of the FVM. The most popular gradient schemes are the divergence theorem (DT) (or Green-Gauss) scheme and the least-squares (LS) scheme. Both are widely believed to be second-order accurate, but the present study shows that in fact the common variant of the DT gradient is second-order accurate only on structured meshes whereas it is zeroth-order accurate on general unstructured meshes, and the LS gradient is second-order and first-order accurate, respectively. This is explained through a theoretical analysis and is confirmed by numerical tests. The schemes are then used within a FVM to solve a simple diffusion equation on unstructured grids generated by several methods; the results reveal that the zeroth-order accuracy of the DT gradient is inherited by the FVM as a whole, and the discretisation error does not decrease with grid refinement. On the other hand, use of the LS gradient leads to second-order accurate results, as does the use of alternative, consistent, DT gradient schemes, including a new iterative scheme that makes the common DT gradient consistent at almost no extra cost. The numerical tests are performed using both an in-house code and the popular public domain partial differential equation solver OpenFOAM.

  13. Decoding spike timing: the differential reverse correlation method

    PubMed Central

    Tkačik, Gašper; Magnasco, Marcelo O.

    2009-01-01

    It is widely acknowledged that detailed timing of action potentials is used to encode information, for example in auditory pathways; however the computational tools required to analyze encoding through timing are still in their infancy. We present a simple example of encoding, based on a recent model of time-frequency analysis, in which units fire action potentials when a certain condition is met, but the timing of the action potential depends also on other features of the stimulus. We show that, as a result, spike-triggered averages are smoothed so much they do not represent the true features of the encoding. Inspired by this example, we present a simple method, differential reverse correlations, that can separate an analysis of what causes a neuron to spike, and what controls its timing. We analyze with this method the leaky integrate-and-fire neuron and show the method accurately reconstructs the model's kernel. PMID:18597928

  14. Charge carrier mobility in thin films of organic semiconductors by the gated van der Pauw method

    PubMed Central

    Rolin, Cedric; Kang, Enpu; Lee, Jeong-Hwan; Borghs, Gustaaf; Heremans, Paul; Genoe, Jan

    2017-01-01

    Thin film transistors based on high-mobility organic semiconductors are prone to contact problems that complicate the interpretation of their electrical characteristics and the extraction of important material parameters such as the charge carrier mobility. Here we report on the gated van der Pauw method for the simple and accurate determination of the electrical characteristics of thin semiconducting films, independently from contact effects. We test our method on thin films of seven high-mobility organic semiconductors of both polarities: device fabrication is fully compatible with common transistor process flows and device measurements deliver consistent and precise values for the charge carrier mobility and threshold voltage in the high-charge carrier density regime that is representative of transistor operation. The gated van der Pauw method is broadly applicable to thin films of semiconductors and enables a simple and clean parameter extraction independent from contact effects. PMID:28397852

  15. Simple, accurate formula for the average bit error probability of multiple-input multiple-output free-space optical links over negative exponential turbulence channels.

    PubMed

    Peppas, Kostas P; Lazarakis, Fotis; Alexandridis, Antonis; Dangakis, Kostas

    2012-08-01

    In this Letter we investigate the error performance of multiple-input multiple-output free-space optical communication systems employing intensity modulation/direct detection and operating over strong atmospheric turbulence channels. Atmospheric-induced strong turbulence fading is modeled using the negative exponential distribution. For the considered system, an approximate yet accurate analytical expression for the average bit error probability is derived and an efficient method for its numerical evaluation is proposed. Numerically evaluated and computer simulation results are further provided to demonstrate the validity of the proposed mathematical analysis.

  16. Energy Measurement Studies for CO2 Measurement with a Coherent Doppler Lidar System

    NASA Technical Reports Server (NTRS)

    Beyon, Jeffrey Y.; Koch, Grady J.; Vanvalkenburg, Randal L.; Yu, Jirong; Singh, Upendra N.; Kavaya, Michael J.

    2010-01-01

    The accurate measurement of energy in the application of lidar system for CO2 measurement is critical. Different techniques of energy estimation in the online and offline pulses are investigated for post processing of lidar returns. The cornerstone of the techniques is the accurate estimation of the spectrum of lidar signal and background noise. Since the background noise is not the ideal white Gaussian noise, simple average level estimation of noise level is not well fit in the energy estimation of lidar signal and noise. A brief review of the methods is presented in this paper.

  17. Modeling State-Space Aeroelastic Systems Using a Simple Matrix Polynomial Approach for the Unsteady Aerodynamics

    NASA Technical Reports Server (NTRS)

    Pototzky, Anthony S.

    2008-01-01

    A simple matrix polynomial approach is introduced for approximating unsteady aerodynamics in the s-plane and ultimately, after combining matrix polynomial coefficients with matrices defining the structure, a matrix polynomial of the flutter equations of motion (EOM) is formed. A technique of recasting the matrix-polynomial form of the flutter EOM into a first order form is also presented that can be used to determine the eigenvalues near the origin and everywhere on the complex plane. An aeroservoelastic (ASE) EOM have been generalized to include the gust terms on the right-hand side. The reasons for developing the new matrix polynomial approach are also presented, which are the following: first, the "workhorse" methods such as the NASTRAN flutter analysis lack the capability to consistently find roots near the origin, along the real axis or accurately find roots farther away from the imaginary axis of the complex plane; and, second, the existing s-plane methods, such as the Roger s s-plane approximation method as implemented in ISAC, do not always give suitable fits of some tabular data of the unsteady aerodynamics. A method available in MATLAB is introduced that will accurately fit generalized aerodynamic force (GAF) coefficients in a tabular data form into the coefficients of a matrix polynomial form. The root-locus results from the NASTRAN pknl flutter analysis, the ISAC-Roger's s-plane method and the present matrix polynomial method are presented and compared for accuracy and for the number and locations of roots.

  18. Speeding up GW Calculations to Meet the Challenge of Large Scale Quasiparticle Predictions

    PubMed Central

    Gao, Weiwei; Xia, Weiyi; Gao, Xiang; Zhang, Peihong

    2016-01-01

    Although the GW approximation is recognized as one of the most accurate theories for predicting materials excited states properties, scaling up conventional GW calculations for large systems remains a major challenge. We present a powerful and simple-to-implement method that can drastically accelerate fully converged GW calculations for large systems, enabling fast and accurate quasiparticle calculations for complex materials systems. We demonstrate the performance of this new method by presenting the results for ZnO and MgO supercells. A speed-up factor of nearly two orders of magnitude is achieved for a system containing 256 atoms (1024 valence electrons) with a negligibly small numerical error of ±0.03 eV. Finally, we discuss the application of our method to the GW calculations for 2D materials. PMID:27833140

  19. Densitometric HPTLC analysis of 8-gingerol in Zingiber officinale extract and ginger-containing dietary supplements, teas and commercial creams

    PubMed Central

    Alam, Prawez

    2013-01-01

    Objective To develop and validate a simple, accurate HPTLC method for the analysis of 8-gingerol and to determine the quantity of 8-gingerol in Zingiber officinale extract and ginger-containing dietary supplements, teas and commercial creams. Methods The analysis was performed on 10×20 cm aluminium-backed plates coated with 0.2 mm layers of silica gel 60 F254 (E-Merck, Germany) with n-hexane: ethyl acetate 60: 40 (v/v) as mobile phase. Camag TLC Scanner III was used for the UV densitometric scanning at 569. Results This system was found to give a compact spot of 8-gingerol at retention factor (Rf) value of (0.39±0.04) and linearity was found in the ranges 50-500 ng/spot (r2=0.9987). Limit of detection (12.76 ng/spot), limit of quantification (26.32 ng/spot), accuracy (less than 2 %) and recovery (ranging from 98.22-99.20) were found satisfactory. Conclusions The HPTLC method developed for quantification of 8-gingerol was found to be simple, accurate, reproducible, sensitive and is applicable to the analysis of 8-gingerol in Zingiber officinale extract and ginger-containing dietary supplements, teas and commercial creams. PMID:23905021

  20. Rapid and sensitive detection of mink circovirus by recombinase polymerase amplification.

    PubMed

    Ge, Junwei; Shi, Yunjia; Cui, Xingyang; Gu, Shanshan; Zhao, Lili; Chen, Hongyan

    2018-06-01

    To date, the pathogenic role of mink circovirus (MiCV) remains unclear, and its prevalence and economic importance are unknown. Therefore, a rapid and sensitive molecular diagnosis is necessary for disease management and epidemiological surveillance. However, only PCR methods can identify MiCV infection at present. In this study, we developed a nested PCR and established a novel recombinase polymerase amplification (RPA) assay for MiCV detection. Sensitivity analysis showed that the detection limit of nested PCR and RPA assay was 10 1 copies/reaction, and these methods were more sensitive than conventional PCR, which has a detection limit of 10 5 copies/reaction. The RPA assay had no cross-reactivity with other related viral pathogens, and amplification was completed in less than 20 min with a simple device. Further assessment of clinical samples showed that the two assays were accurate in identifying positive and negative conventional PCR samples. The detection rate of MiCV by the RPA assay in clinical samples was 38.09%, which was 97% consistent with that by the nested PCR. The developed nested PCR is a highly sensitive tool for practical use, and the RPA assay is a simple, sensitive, and potential alternative method for rapid and accurate MiCV diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Comparative study between different simple methods manipulating ratio spectra for the analysis of alogliptin and metformin co-formulated with highly different concentrations

    NASA Astrophysics Data System (ADS)

    Zaghary, Wafaa A.; Mowaka, Shereen; Hassan, Mostafa A.; Ayoub, Bassam M.

    2017-11-01

    Different simple spectrophotometric methods were developed for simultaneous determination of alogliptin and metformin manipulating their ratio spectra with successful application on recently approved combination, Kazano® tablets. Spiking was implemented to detect alogliptin in spite of its low contribution in the pharmaceutical formulation as low quantity in comparison to metformin. Linearity was acceptable over the concentration range of 2.5-25.0 μg/mL and 2.5-15.0 μg/mL for alogliptin and metformin, respectively using derivative ratio, ratio subtraction coupled with extended ratio subtraction and spectrum subtraction coupled with constant multiplication. The optimized methods were compared using one-way analysis of variance (ANOVA) and proved to be accurate for assay of the investigated drugs in their pharmaceutical dosage form.

  2. Methods for Efficiently and Accurately Computing Quantum Mechanical Free Energies for Enzyme Catalysis.

    PubMed

    Kearns, F L; Hudson, P S; Boresch, S; Woodcock, H L

    2016-01-01

    Enzyme activity is inherently linked to free energies of transition states, ligand binding, protonation/deprotonation, etc.; these free energies, and thus enzyme function, can be affected by residue mutations, allosterically induced conformational changes, and much more. Therefore, being able to predict free energies associated with enzymatic processes is critical to understanding and predicting their function. Free energy simulation (FES) has historically been a computational challenge as it requires both the accurate description of inter- and intramolecular interactions and adequate sampling of all relevant conformational degrees of freedom. The hybrid quantum mechanical molecular mechanical (QM/MM) framework is the current tool of choice when accurate computations of macromolecular systems are essential. Unfortunately, robust and efficient approaches that employ the high levels of computational theory needed to accurately describe many reactive processes (ie, ab initio, DFT), while also including explicit solvation effects and accounting for extensive conformational sampling are essentially nonexistent. In this chapter, we will give a brief overview of two recently developed methods that mitigate several major challenges associated with QM/MM FES: the QM non-Boltzmann Bennett's acceptance ratio method and the QM nonequilibrium work method. We will also describe usage of these methods to calculate free energies associated with (1) relative properties and (2) along reaction paths, using simple test cases with relevance to enzymes examples. © 2016 Elsevier Inc. All rights reserved.

  3. A new experimental method for the determination of the effective orifice area based on the acoustical source term

    NASA Astrophysics Data System (ADS)

    Kadem, L.; Knapp, Y.; Pibarot, P.; Bertrand, E.; Garcia, D.; Durand, L. G.; Rieu, R.

    2005-12-01

    The effective orifice area (EOA) is the most commonly used parameter to assess the severity of aortic valve stenosis as well as the performance of valve substitutes. Particle image velocimetry (PIV) may be used for in vitro estimation of valve EOA. In the present study, we propose a new and simple method based on Howe’s developments of Lighthill’s aero-acoustic theory. This method is based on an acoustical source term (AST) to estimate the EOA from the transvalvular flow velocity measurements obtained by PIV. The EOAs measured by the AST method downstream of three sharp-edged orifices were in excellent agreement with the EOAs predicted from the potential flow theory used as the reference method in this study. Moreover, the AST method was more accurate than other conventional PIV methods based on streamlines, inflexion point or vorticity to predict the theoretical EOAs. The superiority of the AST method is likely due to the nonlinear form of the AST. There was also an excellent agreement between the EOAs measured by the AST method downstream of the three sharp-edged orifices as well as downstream of a bioprosthetic valve with those obtained by the conventional clinical method based on Doppler-echocardiographic measurements of transvalvular velocity. The results of this study suggest that this new simple PIV method provides an accurate estimation of the aortic valve flow EOA. This new method may thus be used as a reference method to estimate the EOA in experimental investigation of the performance of valve substitutes and to validate Doppler-echocardiographic measurements under various physiologic and pathologic flow conditions.

  4. Using the Nudge and Shove Methods to Adjust Item Difficulty Values.

    PubMed

    Royal, Kenneth D

    2015-01-01

    In any examination, it is important that a sufficient mix of items with varying degrees of difficulty be present to produce desirable psychometric properties and increase instructors' ability to make appropriate and accurate inferences about what a student knows and/or can do. The purpose of this "teaching tip" is to demonstrate how examination items can be affected by the quality of distractors, and to present a simple method for adjusting items to meet difficulty specifications.

  5. An approximate Riemann solver for thermal and chemical nonequilibrium flows

    NASA Technical Reports Server (NTRS)

    Prabhu, Ramadas K.

    1994-01-01

    Among the many methods available for the determination of inviscid fluxes across a surface of discontinuity, the flux-difference-splitting technique that employs Roe-averaged variables has been used extensively by the CFD community because of its simplicity and its ability to capture shocks exactly. This method, originally developed for perfect gas flows, has since been extended to equilibrium as well as nonequilibrium flows. Determination of the Roe-averaged variables for the case of a perfect gas flow is a simple task; however, for thermal and chemical nonequilibrium flows, some of the variables are not uniquely defined. Methods available in the literature to determine these variables seem to lack sound bases. The present paper describes a simple, yet accurate, method to determine all the variables for nonequilibrium flows in the Roe-average state. The basis for this method is the requirement that the Roe-averaged variables form a consistent set of thermodynamic variables. The present method satisfies the requirement that the square of the speed of sound be positive.

  6. Image quality evaluation of full reference algorithm

    NASA Astrophysics Data System (ADS)

    He, Nannan; Xie, Kai; Li, Tong; Ye, Yushan

    2018-03-01

    Image quality evaluation is a classic research topic, the goal is to design the algorithm, given the subjective feelings consistent with the evaluation value. This paper mainly introduces several typical reference methods of Mean Squared Error(MSE), Peak Signal to Noise Rate(PSNR), Structural Similarity Image Metric(SSIM) and feature similarity(FSIM) of objective evaluation methods. The different evaluation methods are tested by Matlab, and the advantages and disadvantages of these methods are obtained by analyzing and comparing them.MSE and PSNR are simple, but they are not considered to introduce HVS characteristics into image quality evaluation. The evaluation result is not ideal. SSIM has a good correlation and simple calculation ,because it is considered to the human visual effect into image quality evaluation,However the SSIM method is based on a hypothesis,The evaluation result is limited. The FSIM method can be used for test of gray image and color image test, and the result is better. Experimental results show that the new image quality evaluation algorithm based on FSIM is more accurate.

  7. Assessment of cell concentration and viability of isolated hepatocytes using flow cytometry.

    PubMed

    Wigg, Alan J; Phillips, John W; Wheatland, Loretta; Berry, Michael N

    2003-06-01

    The assessment of cell concentration and viability of freshly isolated hepatocyte preparations has been traditionally performed using manual counting with a Neubauer counting chamber and staining for trypan blue exclusion. Despite the simple and rapid nature of this assessment, concerns about the accuracy of these methods exist. Simple flow cytometry techniques which determine cell concentration and viability are available yet surprisingly have not been extensively used or validated with isolated hepatocyte preparations. We therefore investigated the use of flow cytometry using TRUCOUNT Tubes and propidium iodide staining to measure cell concentration and viability of isolated rat hepatocytes in suspension. Analysis using TRUCOUNT Tubes provided more accurate and reproducible measurement of cell concentration than manual cell counting. Hepatocyte viability, assessed using propidium iodide, correlated more closely than did trypan blue exclusion with all indicators of hepatocyte integrity and function measured (lactate dehydrogenase leakage, cytochrome p450 content, cellular ATP concentration, ammonia and lactate removal, urea and albumin synthesis). We conclude that flow cytometry techniques can be used to measure cell concentration and viability of isolated hepatocyte preparations. The techniques are simple, rapid, and more accurate than manual cell counting and trypan blue staining and the results are not affected by protein-containing media.

  8. Constructing a Measure for Longitudinal Medical Achievement Studies by the Rasch Model One-Step Equating.

    ERIC Educational Resources Information Center

    Shen, Linjun

    As part of a longitudinal study of the growth of general medical knowledge among osteopathic medical students, a simple, convenient, and accurate vertical equating method was developed for constructing a scale for medical achievement. It was believed that Parts 1, 2, and 3 of the National Board of Osteopathic Medical Examiners' (NBOME) examination…

  9. Clinical value of selective serial sectioning of laryngectomy specimens.

    PubMed Central

    Browning, G. G.

    1976-01-01

    A simple routine pathology method for examining laryngectomy specimens has been presented which (1) gives the clinician information regarding the probability of total excision of the tumour; (2) allows more accurate staging of laryngeal tumours; (3) will act as a basis for evaluation of preoperative investigations and future clinical trials of treatment. Images Fig 1 Fig 2 PMID:785476

  10. Densitometric HPTLC analysis of 8-gingerol in Zingiber officinale extract and ginger-containing dietary supplements, teas and commercial creams.

    PubMed

    Alam, Prawez

    2013-08-01

    To develop and validate a simple, accurate HPTLC method for the analysis of 8-gingerol and to determine the quantity of 8-gingerol in Zingiber officinale extract and ginger-containing dietary supplements, teas and commercial creams. The analysis was performed on 10×20 cm aluminium-backed plates coated with 0.2 mm layers of silica gel 60 F254 (E-Merck, Germany) with n-hexane: ethyl acetate 60: 40 (v/v) as mobile phase. Camag TLC Scanner III was used for the UV densitometric scanning at 569. This system was found to give a compact spot of 8-gingerol at retention factor (Rf) value of (0.39±0.04) and linearity was found in the ranges 50-500 ng/spot (r (2)=0.9987). Limit of detection (12.76 ng/spot), limit of quantification (26.32 ng/spot), accuracy (less than 2 %) and recovery (ranging from 98.22-99.20) were found satisfactory. The HPTLC method developed for quantification of 8-gingerol was found to be simple, accurate, reproducible, sensitive and is applicable to the analysis of 8-gingerol in Zingiber officinale extract and ginger-containing dietary supplements, teas and commercial creams.

  11. A simple method for accurate endotracheal placement of an intubation tube in Guinea pigs to assess lung injury following chemical exposure.

    PubMed

    Nambiar, M P; Gordon, R K; Moran, T S; Richards, S M; Sciuto, A M

    2007-01-01

    ABSTRACT Guinea pigs are considered as the animal model of choice for toxicology and medical countermeasure studies against chemical warfare agents (CWAs) and toxic organophosphate pesticides because of the low levels of carboxylesterase compared to rats and mice. However, it is difficult to intubate guinea pigs without damaging the larynx to perform CWA inhalation experiments. We describe an easy technique of intubation of guinea pigs for accurate endotracheal placement of the intubation tube. The technique involves a speculum made by cutting the medium-size ear speculum in the midline leaving behind the intact circular connector to the otoscope. Guinea pigs were anesthetized with Telazol/meditomidine, the tongue was pulled using blunt forceps, and an otoscope attached with the specially prepared speculum was inserted gently. Insertion of the speculum raises the epiglottis and restrains the movements of vocal cord, which allows smooth insertion of the metal stylet-reinforced intubation tube. Accurate endotracheal placement of the intubation tube was achieved by measuring the length from the tracheal bifurcation to vocal cord and vocal cord to the upper front teeth. The average length of the trachea in guinea pigs (275 +/- 25 g) was 5.5 +/- 0.2 cm and the distance from the vocal cord to the front teeth was typically 3 cm. Coinciding an intubation tube marked at 6 cm with the upper front teeth accurately places the intubation tube 2.5 cm above the tracheal bifurcation. This simple method of intubation does not disturb the natural flora of the mouth and causes minimum laryngeal damage. It is rapid and reliable, and will be very valuable in inhalation exposure to chemical/biological warfare agents or toxic chemicals to assess respiratory toxicity and develop medical countermeasures.

  12. DFT-based method for more accurate adsorption energies: An adaptive sum of energies from RPBE and vdW density functionals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hensley, Alyssa J. R.; Ghale, Kushal; Rieg, Carolin

    In recent years, the popularity of density functional theory with periodic boundary conditions (DFT) has surged for the design and optimization of functional materials. However, no single DFT exchange–correlation functional currently available gives accurate adsorption energies on transition metals both when bonding to the surface is dominated by strong covalent or ionic bonding and when it has strong contributions from van der Waals interactions (i.e., dispersion forces). Here we present a new, simple method for accurately predicting adsorption energies on transition-metal surfaces based on DFT calculations, using an adaptively weighted sum of energies from RPBE and optB86b-vdW (or optB88-vdW) densitymore » functionals. This method has been benchmarked against a set of 39 reliable experimental energies for adsorption reactions. Our results show that this method has a mean absolute error and root mean squared error relative to experiments of 13.4 and 19.3 kJ/mol, respectively, compared to 20.4 and 26.4 kJ/mol for the BEEF-vdW functional. For systems with large van der Waals contributions, this method decreases these errors to 11.6 and 17.5 kJ/mol. Furthermore, this method provides predictions of adsorption energies both for processes dominated by strong covalent or ionic bonding and for those dominated by dispersion forces that are more accurate than those of any current standard DFT functional alone.« less

  13. DFT-based method for more accurate adsorption energies: An adaptive sum of energies from RPBE and vdW density functionals

    DOE PAGES

    Hensley, Alyssa J. R.; Ghale, Kushal; Rieg, Carolin; ...

    2017-01-26

    In recent years, the popularity of density functional theory with periodic boundary conditions (DFT) has surged for the design and optimization of functional materials. However, no single DFT exchange–correlation functional currently available gives accurate adsorption energies on transition metals both when bonding to the surface is dominated by strong covalent or ionic bonding and when it has strong contributions from van der Waals interactions (i.e., dispersion forces). Here we present a new, simple method for accurately predicting adsorption energies on transition-metal surfaces based on DFT calculations, using an adaptively weighted sum of energies from RPBE and optB86b-vdW (or optB88-vdW) densitymore » functionals. This method has been benchmarked against a set of 39 reliable experimental energies for adsorption reactions. Our results show that this method has a mean absolute error and root mean squared error relative to experiments of 13.4 and 19.3 kJ/mol, respectively, compared to 20.4 and 26.4 kJ/mol for the BEEF-vdW functional. For systems with large van der Waals contributions, this method decreases these errors to 11.6 and 17.5 kJ/mol. Furthermore, this method provides predictions of adsorption energies both for processes dominated by strong covalent or ionic bonding and for those dominated by dispersion forces that are more accurate than those of any current standard DFT functional alone.« less

  14. Simple to complex modeling of breathing volume using a motion sensor.

    PubMed

    John, Dinesh; Staudenmayer, John; Freedson, Patty

    2013-06-01

    To compare simple and complex modeling techniques to estimate categories of low, medium, and high ventilation (VE) from ActiGraph™ activity counts. Vertical axis ActiGraph™ GT1M activity counts, oxygen consumption and VE were measured during treadmill walking and running, sports, household chores and labor-intensive employment activities. Categories of low (<19.3 l/min), medium (19.3 to 35.4 l/min) and high (>35.4 l/min) VEs were derived from activity intensity classifications (light <2.9 METs, moderate 3.0 to 5.9 METs and vigorous >6.0 METs). We examined the accuracy of two simple techniques (multiple regression and activity count cut-point analyses) and one complex (random forest technique) modeling technique in predicting VE from activity counts. Prediction accuracy of the complex random forest technique was marginally better than the simple multiple regression method. Both techniques accurately predicted VE categories almost 80% of the time. The multiple regression and random forest techniques were more accurate (85 to 88%) in predicting medium VE. Both techniques predicted the high VE (70 to 73%) with greater accuracy than low VE (57 to 60%). Actigraph™ cut-points for light, medium and high VEs were <1381, 1381 to 3660 and >3660 cpm. There were minor differences in prediction accuracy between the multiple regression and the random forest technique. This study provides methods to objectively estimate VE categories using activity monitors that can easily be deployed in the field. Objective estimates of VE should provide a better understanding of the dose-response relationship between internal exposure to pollutants and disease. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. SU-F-J-217: Accurate Dose Volume Parameters Calculation for Revealing Rectum Dose-Toxicity Effect Using Deformable Registration in Cervical Cancer Brachytherapy: A Pilot Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhen, X; Chen, H; Liao, Y

    Purpose: To study the feasibility of employing deformable registration methods for accurate rectum dose volume parameters calculation and their potentials in revealing rectum dose-toxicity between complication and non-complication cervical cancer patients with brachytherapy treatment. Method and Materials: Data from 60 patients treated with BT including planning images, treatment plans, and follow-up clinical exam were retrospectively collected. Among them, 12 patients complained about hematochezia were further examined with colonoscopy and scored as Grade 1–3 complication (CP). Meanwhile, another 12 non-complication (NCP) patients were selected as a reference group. To seek for potential gains in rectum toxicity prediction when fractional anatomical deformationsmore » are account for, the rectum dose volume parameters D0.1/1/2cc of the selected patients were retrospectively computed by three different approaches: the simple “worstcase scenario” (WS) addition method, an intensity-based deformable image registration (DIR) algorithm-Demons, and a more accurate, recent developed local topology preserved non-rigid point matching algorithm (TOP). Statistical significance of the differences between rectum doses of the CP group and the NCP group were tested by a two-tailed t-test and results were considered to be statistically significant if p < 0.05. Results: For the D0.1cc, no statistical differences are found between the CP and NCP group in all three methods. For the D1cc, dose difference is not detected by the WS method, however, statistical differences between the two groups are observed by both Demons and TOP, and more evident in TOP. For the D2cc, the CP and NCP cases are statistically significance of the difference for all three methods but more pronounced with TOP. Conclusion: In this study, we calculated the rectum D0.1/1/2cc by simple WS addition and two DIR methods and seek for gains in rectum toxicity prediction. The results favor the claim that accurate dose deformation and summation tend to be more sensitive in unveiling the dose-toxicity relationship. This work is supported in part by grant from VARIAN MEDICAL SYSTEMS INC, the National Natural Science Foundation of China (no 81428019 and no 81301940), the Guangdong Natural Science Foundation (2015A030313302)and the 2015 Pearl River S&T Nova Program of Guangzhou (201506010096).« less

  16. New method for GC/FID and GC-C-IRMS Analysis of plasma free fatty acid concentration and isotopic enrichment

    PubMed Central

    Kangani, Cyrous O.; Kelley, David E.; DeLany, James P.

    2008-01-01

    A simple, direct and accurate method for the determination of concentration and enrichment of free fatty acids in human plasma was developed. The validation and comparison to a conventional method are reported. Three amide derivatives, dimethyl, diethyl and pyrrolidide, were investigated in order to achieve optimal resolution of the individual fatty acids. This method involves the use of dimethylamine/Deoxo-Fluor to derivatize plasma free fatty acids to their dimethylamides. This derivatization method is very mild and efficient, and is selective only towards free fatty acids so that no separation from a total lipid extract is required. The direct method gave lower concentrations for palmitic acid and stearic acid and increased concentrations for oleic acid and linoleic acid in plasma as compared to methylester derivative after thin-layer chromatography. The [13C]palmitate isotope enrichment measured using direct method was significantly higher than that observed with the BF3/MeOH-TLC method. The present method provided accurate and precise measures of concentration as well as enrichment when analyzed with gas chromatography combustion-isotope ratio-mass spectrometry. PMID:18757250

  17. New method for GC/FID and GC-C-IRMS analysis of plasma free fatty acid concentration and isotopic enrichment.

    PubMed

    Kangani, Cyrous O; Kelley, David E; Delany, James P

    2008-09-15

    A simple, direct and accurate method for the determination of concentration and enrichment of free fatty acids (FFAs) in human plasma was developed. The validation and comparison to a conventional method are reported. Three amide derivatives, dimethyl, diethyl and pyrrolidide, were investigated in order to achieve optimal resolution of the individual fatty acids. This method involves the use of dimethylamine/Deoxo-Fluor to derivatize plasma free fatty acids to their dimethylamides. This derivatization method is very mild and efficient, and is selective only towards FFAs so that no separation from a total lipid extract is required. The direct method gave lower concentrations for palmitic acid and stearic acid and increased concentrations for oleic acid and linoleic acid in plasma as compared to methyl ester derivative after thin-layer chromatography. The [(13)C]palmitate isotope enrichment measured using direct method was significantly higher than that observed with the BF(3)/MeOH-TLC method. The present method provided accurate and precise measures of concentration as well as enrichment when analyzed with gas chromatography combustion-isotope ratio-mass spectrometry.

  18. Simple, Sensitive and Accurate Multiplex Detection of Clinically Important Melanoma DNA Mutations in Circulating Tumour DNA with SERS Nanotags

    PubMed Central

    Wee, Eugene J.H.; Wang, Yuling; Tsao, Simon Chang-Hao; Trau, Matt

    2016-01-01

    Sensitive and accurate identification of specific DNA mutations can influence clinical decisions. However accurate diagnosis from limiting samples such as circulating tumour DNA (ctDNA) is challenging. Current approaches based on fluorescence such as quantitative PCR (qPCR) and more recently, droplet digital PCR (ddPCR) have limitations in multiplex detection, sensitivity and the need for expensive specialized equipment. Herein we describe an assay capitalizing on the multiplexing and sensitivity benefits of surface-enhanced Raman spectroscopy (SERS) with the simplicity of standard PCR to address the limitations of current approaches. This proof-of-concept method could reproducibly detect as few as 0.1% (10 copies, CV < 9%) of target sequences thus demonstrating the high sensitivity of the method. The method was then applied to specifically detect three important melanoma mutations in multiplex. Finally, the PCR/SERS assay was used to genotype cell lines and ctDNA from serum samples where results subsequently validated with ddPCR. With ddPCR-like sensitivity and accuracy yet at the convenience of standard PCR, we believe this multiplex PCR/SERS method could find wide applications in both diagnostics and research. PMID:27446486

  19. Simple, Sensitive and Accurate Multiplex Detection of Clinically Important Melanoma DNA Mutations in Circulating Tumour DNA with SERS Nanotags.

    PubMed

    Wee, Eugene J H; Wang, Yuling; Tsao, Simon Chang-Hao; Trau, Matt

    2016-01-01

    Sensitive and accurate identification of specific DNA mutations can influence clinical decisions. However accurate diagnosis from limiting samples such as circulating tumour DNA (ctDNA) is challenging. Current approaches based on fluorescence such as quantitative PCR (qPCR) and more recently, droplet digital PCR (ddPCR) have limitations in multiplex detection, sensitivity and the need for expensive specialized equipment. Herein we describe an assay capitalizing on the multiplexing and sensitivity benefits of surface-enhanced Raman spectroscopy (SERS) with the simplicity of standard PCR to address the limitations of current approaches. This proof-of-concept method could reproducibly detect as few as 0.1% (10 copies, CV < 9%) of target sequences thus demonstrating the high sensitivity of the method. The method was then applied to specifically detect three important melanoma mutations in multiplex. Finally, the PCR/SERS assay was used to genotype cell lines and ctDNA from serum samples where results subsequently validated with ddPCR. With ddPCR-like sensitivity and accuracy yet at the convenience of standard PCR, we believe this multiplex PCR/SERS method could find wide applications in both diagnostics and research.

  20. A pairwise maximum entropy model accurately describes resting-state human brain networks

    PubMed Central

    Watanabe, Takamitsu; Hirose, Satoshi; Wada, Hiroyuki; Imai, Yoshio; Machida, Toru; Shirouzu, Ichiro; Konishi, Seiki; Miyashita, Yasushi; Masuda, Naoki

    2013-01-01

    The resting-state human brain networks underlie fundamental cognitive functions and consist of complex interactions among brain regions. However, the level of complexity of the resting-state networks has not been quantified, which has prevented comprehensive descriptions of the brain activity as an integrative system. Here, we address this issue by demonstrating that a pairwise maximum entropy model, which takes into account region-specific activity rates and pairwise interactions, can be robustly and accurately fitted to resting-state human brain activities obtained by functional magnetic resonance imaging. Furthermore, to validate the approximation of the resting-state networks by the pairwise maximum entropy model, we show that the functional interactions estimated by the pairwise maximum entropy model reflect anatomical connexions more accurately than the conventional functional connectivity method. These findings indicate that a relatively simple statistical model not only captures the structure of the resting-state networks but also provides a possible method to derive physiological information about various large-scale brain networks. PMID:23340410

  1. Error Reduction Program. [combustor performance evaluation codes

    NASA Technical Reports Server (NTRS)

    Syed, S. A.; Chiappetta, L. M.; Gosman, A. D.

    1985-01-01

    The details of a study to select, incorporate and evaluate the best available finite difference scheme to reduce numerical error in combustor performance evaluation codes are described. The combustor performance computer programs chosen were the two dimensional and three dimensional versions of Pratt & Whitney's TEACH code. The criteria used to select schemes required that the difference equations mirror the properties of the governing differential equation, be more accurate than the current hybrid difference scheme, be stable and economical, be compatible with TEACH codes, use only modest amounts of additional storage, and be relatively simple. The methods of assessment used in the selection process consisted of examination of the difference equation, evaluation of the properties of the coefficient matrix, Taylor series analysis, and performance on model problems. Five schemes from the literature and three schemes developed during the course of the study were evaluated. This effort resulted in the incorporation of a scheme in 3D-TEACH which is usuallly more accurate than the hybrid differencing method and never less accurate.

  2. Benchmark solutions for the galactic ion transport equations: Energy and spatially dependent problems

    NASA Technical Reports Server (NTRS)

    Ganapol, Barry D.; Townsend, Lawrence W.; Wilson, John W.

    1989-01-01

    Nontrivial benchmark solutions are developed for the galactic ion transport (GIT) equations in the straight-ahead approximation. These equations are used to predict potential radiation hazards in the upper atmosphere and in space. Two levels of difficulty are considered: (1) energy independent, and (2) spatially independent. The analysis emphasizes analytical methods never before applied to the GIT equations. Most of the representations derived have been numerically implemented and compared to more approximate calculations. Accurate ion fluxes are obtained (3 to 5 digits) for nontrivial sources. For monoenergetic beams, both accurate doses and fluxes are found. The benchmarks presented are useful in assessing the accuracy of transport algorithms designed to accommodate more complex radiation protection problems. In addition, these solutions can provide fast and accurate assessments of relatively simple shield configurations.

  3. Accurate radiation temperature and chemical potential from quantitative photoluminescence analysis of hot carrier populations.

    PubMed

    Gibelli, François; Lombez, Laurent; Guillemoles, Jean-François

    2017-02-15

    In order to characterize hot carrier populations in semiconductors, photoluminescence measurement is a convenient tool, enabling us to probe the carrier thermodynamical properties in a contactless way. However, the analysis of the photoluminescence spectra is based on some assumptions which will be discussed in this work. We especially emphasize the importance of the variation of the material absorptivity that should be considered to access accurate thermodynamical properties of the carriers, especially by varying the excitation power. The proposed method enables us to obtain more accurate results of thermodynamical properties by taking into account a rigorous physical description and finds direct application in investigating hot carrier solar cells, which are an adequate concept for achieving high conversion efficiencies with a relatively simple device architecture.

  4. Methods for developing time-series climate surfaces to drive topographically distributed energy- and water-balance models

    USGS Publications Warehouse

    Susong, D.; Marks, D.; Garen, D.

    1999-01-01

    Topographically distributed energy- and water-balance models can accurately simulate both the development and melting of a seasonal snowcover in the mountain basins. To do this they require time-series climate surfaces of air temperature, humidity, wind speed, precipitation, and solar and thermal radiation. If data are available, these parameters can be adequately estimated at time steps of one to three hours. Unfortunately, climate monitoring in mountain basins is very limited, and the full range of elevations and exposures that affect climate conditions, snow deposition, and melt is seldom sampled. Detailed time-series climate surfaces have been successfully developed using limited data and relatively simple methods. We present a synopsis of the tools and methods used to combine limited data with simple corrections for the topographic controls to generate high temporal resolution time-series images of these climate parameters. Methods used include simulations, elevational gradients, and detrended kriging. The generated climate surfaces are evaluated at points and spatially to determine if they are reasonable approximations of actual conditions. Recommendations are made for the addition of critical parameters and measurement sites into routine monitoring systems in mountain basins.Topographically distributed energy- and water-balance models can accurately simulate both the development and melting of a seasonal snowcover in the mountain basins. To do this they require time-series climate surfaces of air temperature, humidity, wind speed, precipitation, and solar and thermal radiation. If data are available, these parameters can be adequately estimated at time steps of one to three hours. Unfortunately, climate monitoring in mountain basins is very limited, and the full range of elevations and exposures that affect climate conditions, snow deposition, and melt is seldom sampled. Detailed time-series climate surfaces have been successfully developed using limited data and relatively simple methods. We present a synopsis of the tools and methods used to combine limited data with simple corrections for the topographic controls to generate high temporal resolution time-series images of these climate parameters. Methods used include simulations, elevational gradients, and detrended kriging. The generated climate surfaces are evaluated at points and spatially to determine if they are reasonable approximations of actual conditions. Recommendations are made for the addition of critical parameters and measurement sites into routine monitoring systems in mountain basins.

  5. High throughput single cell counting in droplet-based microfluidics.

    PubMed

    Lu, Heng; Caen, Ouriel; Vrignon, Jeremy; Zonta, Eleonora; El Harrak, Zakaria; Nizard, Philippe; Baret, Jean-Christophe; Taly, Valérie

    2017-05-02

    Droplet-based microfluidics is extensively and increasingly used for high-throughput single-cell studies. However, the accuracy of the cell counting method directly impacts the robustness of such studies. We describe here a simple and precise method to accurately count a large number of adherent and non-adherent human cells as well as bacteria. Our microfluidic hemocytometer provides statistically relevant data on large populations of cells at a high-throughput, used to characterize cell encapsulation and cell viability during incubation in droplets.

  6. GRAVIMETRIC DETERMINATION OF PLATINIUM, PALLADIUM, RUTHENIUM, RHODIUM AS TlPtS$sub 3$, TlPd$sub 2$S$sub 3$, TlRu$sub 2$S$sub 6$, TlRh$sub 2$S$sub 4$ (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudnev, N.A.; Malofeeva, G.I.

    1963-07-01

    Gravimetric methods were developed for the determination of microamounts of Ru, Rh, Pt, and Pd as TlRu/sub 2/S/sub 6/, TlRh/sub 2/S/sub 4/ TlPtS/sub 3/, and TlPd/sub 2/S/sub 3/. The methods are simpl e, rapid, and satisfactorily accurate. (auth)

  7. Horizontal lifelines - review of regulations and simple design method considering anchorage rigidity.

    PubMed

    Galy, Bertrand; Lan, André

    2018-03-01

    Among the many occupational risks construction workers encounter every day falling from a height is the most dangerous. The objective of this article is to propose a simple analytical design method for horizontal lifelines (HLLs) that considers anchorage flexibility. The article presents a short review of the standards and regulations/acts/codes concerning HLLs in Canada the USA and Europe. A static analytical approach is proposed considering anchorage flexibility. The analytical results are compared with a series of 42 dynamic fall tests and a SAP2000 numerical model. The experimental results show that the analytical method is a little conservative and overestimates the line tension in most cases with a maximum of 17%. The static SAP2000 results show a maximum 2.1% difference with the analytical method. The analytical method is accurate enough to safely design HLLs and quick design abaci are provided to allow the engineer to make quick on-site verification if needed.

  8. Hormonal profiling: Development of a simple method to extract and quantify phytohormones in complex matrices by UHPLC-MS/MS.

    PubMed

    Delatorre, Carolina; Rodríguez, Ana; Rodríguez, Lucía; Majada, Juan P; Ordás, Ricardo J; Feito, Isabel

    2017-01-01

    Plant growth regulators (PGRs) are very different chemical compounds that play essential roles in plant development and the regulation of physiological processes. They exert their functions by a mechanism called cross-talk (involving either synergistic or antagonistic actions) thus; it is for great interest to study as many PGRs as possible to obtain accurate information about plant status. Much effort has been applied to develop methods capable of analyze large numbers of these compounds but frequently excluding some chemical families or important PGRs within each family. In addition, most of the methods are specially designed for matrices easy to work with. Therefore, we wanted to develop a method which achieved the requirements lacking in the literature and also being fast and reliable. Here we present a simple, fast and robust method for the extraction and quantification of 20 different PGRs using UHPLC-MS/MS optimized in complex matrices. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. The estimation of tree posterior probabilities using conditional clade probability distributions.

    PubMed

    Larget, Bret

    2013-07-01

    In this article I introduce the idea of conditional independence of separated subtrees as a principle by which to estimate the posterior probability of trees using conditional clade probability distributions rather than simple sample relative frequencies. I describe an algorithm for these calculations and software which implements these ideas. I show that these alternative calculations are very similar to simple sample relative frequencies for high probability trees but are substantially more accurate for relatively low probability trees. The method allows the posterior probability of unsampled trees to be calculated when these trees contain only clades that are in other sampled trees. Furthermore, the method can be used to estimate the total probability of the set of sampled trees which provides a measure of the thoroughness of a posterior sample.

  10. 3D Documentation and BIM Modeling of Cultural Heritage Structures Using UAVs: The Case of the Foinikaria Church

    NASA Astrophysics Data System (ADS)

    Themistocleous, K.; Agapiou, A.; Hadjimitsis, D.

    2016-10-01

    The documentation of architectural cultural heritage sites has traditionally been expensive and labor-intensive. New innovative technologies, such as Unmanned Aerial Vehicles (UAVs), provide an affordable, reliable and straightforward method of capturing cultural heritage sites, thereby providing a more efficient and sustainable approach to documentation of cultural heritage structures. In this study, hundreds of images of the Panagia Chryseleousa church in Foinikaria, Cyprus were taken using a UAV with an attached high resolution camera. The images were processed to generate an accurate digital 3D model by using Structure in Motion techniques. Building Information Model (BIM) was then used to generate drawings of the church. The methodology described in the paper provides an accurate, simple and cost-effective method of documenting cultural heritage sites and generating digital 3D models using novel techniques and innovative methods.

  11. A simple and rapid creatinine sensing via DLS selectivity, using calix[4]arene thiol functionalized gold nanoparticles.

    PubMed

    Sutariya, Pinkesh G; Pandya, Alok; Lodha, Anand; Menon, Shobhana K

    2016-01-15

    A new, simple, ultra-sensitive and selective approach has been reported for the "on spot" colorimetric detection of creatinine based on calix[4]arene functionalized gold nanoparticles (AuNPs) with excellent discrimination in the presence of other biomolecules. The lower detection limit of the method is 2.16nM. The gold nanoparticles and p-tert-butylcalix[4]arene were synthesized by microwave assisted method. Specifically, in our study, we used dynamic light scattering (DLS) which is a powerful method for the determination of small changes in particle size, improved selectivity and sensitivity of the creatinine detection system over colorimetric method. The nanoassembly is characterized by Transmission electron microscopy (TEM), DLS, UV-vis and ESI-MS spectroscopy, which demonstrates the binding affinity due its ability of hydrogen bonding and electrostatic interaction between -NH group of creatinine and pSDSC4. It exhibits fast response time (<60s) to creatinine and has long shelf-life (>5 weeks). The developed pSDSC4-AuNPs based creatinine biosensor will be established as simple, reliable and accurate tool for the determination of creatinine in human urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Validation and Application of a Simple UHPLC–MS-MS Method for the Enantiospecific Determination of Warfarin in Human Urine

    PubMed Central

    Alshogran, Osama Y.; Ocque, Andrew J.; Leblond, François A.; Pichette, Vincent; Nolin, Thomas D.

    2016-01-01

    A simple and rapid liquid chromatographic–tandem mass spectrometric method has been developed and validated for the enantiospecific determination of R- and S-warfarin in human urine. Warfarin enantiomers were extracted from urine using methyl tert-butyl ether. Chromatographic separation of warfarin enantiomers and the internal standard d5-warfarin was achieved using a Astec Chirobiotic V column with gradient mobile phase at a flow rate of 400 µL/min over 10 min. Detection was performed on a TSQ Quantum Ultra triple quadrupole mass spectrometer equipped with a heated electrospray ionization source. Analytes were detected in negative ionization mode using selected reaction monitoring. Calibration curves were linear with a correlation coefficient of ≥0.996 for both enantiomers over a concentration range of 5–500 ng/mL. The intra- and interday accuracy and precision for both analytes were within ±9.0%. Excellent extraction efficiency and negligible matrix effects were observed. The applicability of the method was demonstrated by successful measurement of warfarin enantiomers in urine of patients with kidney disease. The method is simple, accurate and reproducible and is currently being used to support warfarin pharmacokinetic studies. PMID:26657732

  13. Control surface hinge moment prediction using computational fluid dynamics

    NASA Astrophysics Data System (ADS)

    Simpson, Christopher David

    The following research determines the feasibility of predicting control surface hinge moments using various computational methods. A detailed analysis is conducted using a 2D GA(W)-1 airfoil with a 20% plain flap. Simple hinge moment prediction methods are tested, including empirical Datcom relations and XFOIL. Steady-state and time-accurate turbulent, viscous, Navier-Stokes solutions are computed using Fun3D. Hinge moment coefficients are computed. Mesh construction techniques are discussed. An adjoint-based mesh adaptation case is also evaluated. An NACA 0012 45-degree swept horizontal stabilizer with a 25% elevator is also evaluated using Fun3D. Results are compared with experimental wind-tunnel data obtained from references. Finally, the costs of various solution methods are estimated. Results indicate that while a steady-state Navier-Stokes solution can accurately predict control surface hinge moments for small angles of attack and deflection angles, a time-accurate solution is necessary to accurately predict hinge moments in the presence of flow separation. The ability to capture the unsteady vortex shedding behavior present in moderate to large control surface deflections is found to be critical to hinge moment prediction accuracy. Adjoint-based mesh adaptation is shown to give hinge moment predictions similar to a globally-refined mesh for a steady-state 2D simulation.

  14. Fault identification of rotor-bearing system based on ensemble empirical mode decomposition and self-zero space projection analysis

    NASA Astrophysics Data System (ADS)

    Jiang, Fan; Zhu, Zhencai; Li, Wei; Zhou, Gongbo; Chen, Guoan

    2014-07-01

    Accurately identifying faults in rotor-bearing systems by analyzing vibration signals, which are nonlinear and nonstationary, is challenging. To address this issue, a new approach based on ensemble empirical mode decomposition (EEMD) and self-zero space projection analysis is proposed in this paper. This method seeks to identify faults appearing in a rotor-bearing system using simple algebraic calculations and projection analyses. First, EEMD is applied to decompose the collected vibration signals into a set of intrinsic mode functions (IMFs) for features. Second, these extracted features under various mechanical health conditions are used to design a self-zero space matrix according to space projection analysis. Finally, the so-called projection indicators are calculated to identify the rotor-bearing system's faults with simple decision logic. Experiments are implemented to test the reliability and effectiveness of the proposed approach. The results show that this approach can accurately identify faults in rotor-bearing systems.

  15. A Time-Accurate Upwind Unstructured Finite Volume Method for Compressible Flow with Cure of Pathological Behaviors

    NASA Technical Reports Server (NTRS)

    Loh, Ching Y.; Jorgenson, Philip C. E.

    2007-01-01

    A time-accurate, upwind, finite volume method for computing compressible flows on unstructured grids is presented. The method is second order accurate in space and time and yields high resolution in the presence of discontinuities. For efficiency, the Roe approximate Riemann solver with an entropy correction is employed. In the basic Euler/Navier-Stokes scheme, many concepts of high order upwind schemes are adopted: the surface flux integrals are carefully treated, a Cauchy-Kowalewski time-stepping scheme is used in the time-marching stage, and a multidimensional limiter is applied in the reconstruction stage. However even with these up-to-date improvements, the basic upwind scheme is still plagued by the so-called "pathological behaviors," e.g., the carbuncle phenomenon, the expansion shock, etc. A solution to these limitations is presented which uses a very simple dissipation model while still preserving second order accuracy. This scheme is referred to as the enhanced time-accurate upwind (ETAU) scheme in this paper. The unstructured grid capability renders flexibility for use in complex geometry; and the present ETAU Euler/Navier-Stokes scheme is capable of handling a broad spectrum of flow regimes from high supersonic to subsonic at very low Mach number, appropriate for both CFD (computational fluid dynamics) and CAA (computational aeroacoustics). Numerous examples are included to demonstrate the robustness of the methods.

  16. A technique for measuring petal gloss, with examples from the Namaqualand flora.

    PubMed

    Whitney, Heather M; Rands, Sean A; Elton, Nick J; Ellis, Allan G

    2012-01-01

    The degree of floral gloss varies between species. However, little is known about this distinctive floral trait, even though it could be a key feature of floral biotic and abiotic interactions. One reason for the absence of knowledge is the lack of a simple, repeatable method of gloss measurement that can be used in the field to study floral gloss. A protocol is described for measuring gloss in petal samples collected in the field, using a glossmeter. Repeatability of the technique is assessed. We demonstrate a simple yet highly accurate and repeatable method that can easily be implemented in the field. We also highlight the huge variety of glossiness found within flowers and between species in a sample of spring-blooming flowers collected in Namaqualand, South Africa. We discuss the potential uses of this method and its applications for furthering studies in plant-pollinator interactions. We also discuss the potential functions of gloss in flowers.

  17. Comparative study between different simple methods manipulating ratio spectra for the analysis of alogliptin and metformin co-formulated with highly different concentrations.

    PubMed

    Zaghary, Wafaa A; Mowaka, Shereen; Hassan, Mostafa A; Ayoub, Bassam M

    2017-11-05

    Different simple spectrophotometric methods were developed for simultaneous determination of alogliptin and metformin manipulating their ratio spectra with successful application on recently approved combination, Kazano® tablets. Spiking was implemented to detect alogliptin in spite of its low contribution in the pharmaceutical formulation as low quantity in comparison to metformin. Linearity was acceptable over the concentration range of 2.5-25.0μg/mL and 2.5-15.0μg/mL for alogliptin and metformin, respectively using derivative ratio, ratio subtraction coupled with extended ratio subtraction and spectrum subtraction coupled with constant multiplication. The optimized methods were compared using one-way analysis of variance (ANOVA) and proved to be accurate for assay of the investigated drugs in their pharmaceutical dosage form. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Simple and universal model for electron-impact ionization of complex biomolecules

    NASA Astrophysics Data System (ADS)

    Tan, Hong Qi; Mi, Zhaohong; Bettiol, Andrew A.

    2018-03-01

    We present a simple and universal approach to calculate the total ionization cross section (TICS) for electron impact ionization in DNA bases and other biomaterials in the condensed phase. Evaluating the electron impact TICS plays a vital role in ion-beam radiobiology simulation at the cellular level, as secondary electrons are the main cause of DNA damage in particle cancer therapy. Our method is based on extending the dielectric formalism. The calculated results agree well with experimental data and show a good comparison with other theoretical calculations. This method only requires information of the chemical composition and density and an estimate of the mean binding energy to produce reasonably accurate TICS of complex biomolecules. Because of its simplicity and great predictive effectiveness, this method could be helpful in situations where the experimental TICS data are absent or scarce, such as in particle cancer therapy.

  19. Numerical tilting compensation in microscopy based on wavefront sensing using transport of intensity equation method

    NASA Astrophysics Data System (ADS)

    Hu, Junbao; Meng, Xin; Wei, Qi; Kong, Yan; Jiang, Zhilong; Xue, Liang; Liu, Fei; Liu, Cheng; Wang, Shouyu

    2018-03-01

    Wide-field microscopy is commonly used for sample observations in biological research and medical diagnosis. However, the tilting error induced by the oblique location of the image recorder or the sample, as well as the inclination of the optical path often deteriorates the imaging quality. In order to eliminate the tilting in microscopy, a numerical tilting compensation technique based on wavefront sensing using transport of intensity equation method is proposed in this paper. Both the provided numerical simulations and practical experiments prove that the proposed technique not only accurately determines the tilting angle with simple setup and procedures, but also compensates the tilting error for imaging quality improvement even in the large tilting cases. Considering its simple systems and operations, as well as image quality improvement capability, it is believed the proposed method can be applied for tilting compensation in the optical microscopy.

  20. Road simulation for four-wheel vehicle whole input power spectral density

    NASA Astrophysics Data System (ADS)

    Wang, Jiangbo; Qiang, Baomin

    2017-05-01

    As the vibration of running vehicle mainly comes from road and influence vehicle ride performance. So the road roughness power spectral density simulation has great significance to analyze automobile suspension vibration system parameters and evaluate ride comfort. Firstly, this paper based on the mathematical model of road roughness power spectral density, established the integral white noise road random method. Then in the MATLAB/Simulink environment, according to the research method of automobile suspension frame from simple two degree of freedom single-wheel vehicle model to complex multiple degrees of freedom vehicle model, this paper built the simple single incentive input simulation model. Finally the spectrum matrix was used to build whole vehicle incentive input simulation model. This simulation method based on reliable and accurate mathematical theory and can be applied to the random road simulation of any specified spectral which provides pavement incentive model and foundation to vehicle ride performance research and vibration simulation.

  1. Development and validation of high-performance liquid chromatography and high-performance thin-layer chromatography methods for the quantification of khellin in Ammi visnaga seed

    PubMed Central

    Kamal, Abid; Khan, Washim; Ahmad, Sayeed; Ahmad, F. J.; Saleem, Kishwar

    2015-01-01

    Objective: The present study was used to design simple, accurate and sensitive reversed phase-high-performance liquid chromatography RP-HPLC and high-performance thin-layer chromatography (HPTLC) methods for the development of quantification of khellin present in the seeds of Ammi visnaga. Materials and Methods: RP-HPLC analysis was performed on a C18 column with methanol: Water (75: 25, v/v) as a mobile phase. The HPTLC method involved densitometric evaluation of khellin after resolving it on silica gel plate using ethyl acetate: Toluene: Formic acid (5.5:4.0:0.5, v/v/v) as a mobile phase. Results: The developed HPLC and HPTLC methods were validated for precision (interday, intraday and intersystem), robustness and accuracy, limit of detection and limit of quantification. The relationship between the concentration of standard solutions and the peak response was linear in both HPLC and HPTLC methods with the concentration range of 10–80 μg/mL in HPLC and 25–1,000 ng/spot in HPTLC for khellin. The % relative standard deviation values for method precision was found to be 0.63–1.97%, 0.62–2.05% in HPLC and HPTLC for khellin respectively. Accuracy of the method was checked by recovery studies conducted at three different concentration levels and the average percentage recovery was found to be 100.53% in HPLC and 100.08% in HPTLC for khellin. Conclusions: The developed HPLC and HPTLC methods for the quantification of khellin were found simple, precise, specific, sensitive and accurate which can be used for routine analysis and quality control of A. visnaga and several formulations containing it as an ingredient. PMID:26681890

  2. Simple and sensitive analysis of blonanserin and blonanserin C in human plasma by liquid chromatography tandem mass spectrometry and its application.

    PubMed

    Zheng, Yunliang; Hu, Xingjiang; Liu, Jian; Wu, Guolan; Zhou, Huili; Zhu, Meixiang; Zhai, You; Wu, Lihua; Shentu, Jianzhong

    2014-01-01

    A highly sensitive, simple, and rapid liquid chromatography tandem mass spectrometry method to simultaneously determine blonanserin and blonanserin C in human plasma with AD-5332 as internal standard (IS) was established. A simple direct protein precipitation method was used for the sample pretreatment, and chromatographic separation was performed on a Waters XBridge C8 (4.6 × 150 mm, 3.5  μ m) column. The mobile phase consists of a mixture of 10 mM ammonium formate and 0.1% formic acid in water (A) and 0.1% formic acid in methanol (B). To quantify blonanserin, blonanserin C, and IS, multiple reaction monitoring (MRM) was performed in positive ESI mode. The calibration curve was linear in the concentration range of 0.012-5.78 ng·mL(-1) for blonanserin and 0.023-11.57 ng·mL(-1) for blonanserin C (r (2) > 0.9990). The intra- and interday precision of three quality control (QC) levels in plasma were less than 7.5%. Finally, the current simple, sensitive, and accurate LC-MS/MS method was successfully applied to investigate the pharmacokinetics of blonanserin and blonanserin C in healthy Chinese volunteers.

  3. Simple and Sensitive Analysis of Blonanserin and Blonanserin C in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry and Its Application

    PubMed Central

    Zheng, Yunliang; Hu, Xingjiang; Liu, Jian; Wu, Guolan; Zhou, Huili; Zhu, Meixiang; Zhai, You; Wu, Lihua; ShenTu, Jianzhong

    2014-01-01

    A highly sensitive, simple, and rapid liquid chromatography tandem mass spectrometry method to simultaneously determine blonanserin and blonanserin C in human plasma with AD-5332 as internal standard (IS) was established. A simple direct protein precipitation method was used for the sample pretreatment, and chromatographic separation was performed on a Waters XBridge C8 (4.6 × 150 mm, 3.5 μm) column. The mobile phase consists of a mixture of 10 mM ammonium formate and 0.1% formic acid in water (A) and 0.1% formic acid in methanol (B). To quantify blonanserin, blonanserin C, and IS, multiple reaction monitoring (MRM) was performed in positive ESI mode. The calibration curve was linear in the concentration range of 0.012–5.78 ng·mL−1 for blonanserin and 0.023–11.57 ng·mL−1 for blonanserin C (r 2 > 0.9990). The intra- and interday precision of three quality control (QC) levels in plasma were less than 7.5%. Finally, the current simple, sensitive, and accurate LC-MS/MS method was successfully applied to investigate the pharmacokinetics of blonanserin and blonanserin C in healthy Chinese volunteers. PMID:24678425

  4. A conservative finite difference algorithm for the unsteady transonic potential equation in generalized coordinates

    NASA Technical Reports Server (NTRS)

    Bridgeman, J. O.; Steger, J. L.; Caradonna, F. X.

    1982-01-01

    An implicit, approximate-factorization, finite-difference algorithm has been developed for the computation of unsteady, inviscid transonic flows in two and three dimensions. The computer program solves the full-potential equation in generalized coordinates in conservation-law form in order to properly capture shock-wave position and speed. A body-fitted coordinate system is employed for the simple and accurate treatment of boundary conditions on the body surface. The time-accurate algorithm is modified to a conventional ADI relaxation scheme for steady-state computations. Results from two- and three-dimensional steady and two-dimensional unsteady calculations are compared with existing methods.

  5. Oligonucleotide (GTG)5 as an epidemiological tool in the study of nontuberculous mycobacteria.

    PubMed Central

    Cilliers, F J; Warren, R M; Hauman, J H; Wiid, I J; van Helden, P D

    1997-01-01

    Analysis of restriction fragment length polymorphisms in the genome of Mycobacterium tuberculosis (DNA fingerprinting) has proved to be a useful epidemiological tool in the study of tuberculosis within populations or communities. However, to date, no similar method has been developed to study the epidemiology of nontuberculous mycobacteria (NTM). In this communication, we report that a simple oligonucleotide repeat, (GTG)5, can be used to accurately genotype all species and strains of NTM tested. We suggest that this technology is an easily applied and accurate tool which can be used for the study of the epidemiology of NTM. PMID:9163479

  6. A wave superposition method formulated in digital acoustic space

    NASA Astrophysics Data System (ADS)

    Hwang, Yong-Sin

    In this thesis, a new formulation of the Wave Superposition method is proposed wherein the conventional mesh approach is replaced by a simple 3-D digital work space that easily accommodates shape optimization for minimizing or maximizing radiation efficiency. As sound quality is in demand in almost all product designs and also because of fierce competition between product manufacturers, faster and accurate computational method for shape optimization is always desired. Because the conventional Wave Superposition method relies solely on mesh geometry, it cannot accommodate fast shape changes in the design stage of a consumer product or machinery, where many iterations of shape changes are required. Since the use of a mesh hinders easy shape changes, a new approach for representing geometry is introduced by constructing a uniform lattice in a 3-D digital work space. A voxel (a portmanteau, a new word made from combining the sound and meaning, of the words, volumetric and pixel) is essentially a volume element defined by the uniform lattice, and does not require separate connectivity information as a mesh element does. In the presented method, geometry is represented with voxels that can easily adapt to shape changes, therefore it is more suitable for shape optimization. The new method was validated by computing radiated sound power of structures of simple and complex geometries and complex mode shapes. It was shown that matching volume velocity is a key component to an accurate analysis. A sensitivity study showed that it required at least 6 elements per acoustic wavelength, and a complexity study showed a minimal reduction in computational time.

  7. Direct quantification of lipopeptide biosurfactants in biological samples via HPLC and UPLC-MS requires sample modification with an organic solvent.

    PubMed

    Biniarz, Piotr; Łukaszewicz, Marcin

    2017-06-01

    The rapid and accurate quantification of biosurfactants in biological samples is challenging. In contrast to the orcinol method for rhamnolipids, no simple biochemical method is available for the rapid quantification of lipopeptides. Various liquid chromatography (LC) methods are promising tools for relatively fast and exact quantification of lipopeptides. Here, we report strategies for the quantification of the lipopeptides pseudofactin and surfactin in bacterial cultures using different high- (HPLC) and ultra-performance liquid chromatography (UPLC) systems. We tested three strategies for sample pretreatment prior to LC analysis. In direct analysis (DA), bacterial cultures were injected directly and analyzed via LC. As a modification, we diluted the samples with methanol and detected an increase in lipopeptide recovery in the presence of methanol. Therefore, we suggest this simple modification as a tool for increasing the accuracy of LC methods. We also tested freeze-drying followed by solvent extraction (FDSE) as an alternative for the analysis of "heavy" samples. In FDSE, the bacterial cultures were freeze-dried, and the resulting powder was extracted with different solvents. Then, the organic extracts were analyzed via LC. Here, we determined the influence of the extracting solvent on lipopeptide recovery. HPLC methods allowed us to quantify pseudofactin and surfactin with run times of 15 and 20 min per sample, respectively, whereas UPLC quantification was as fast as 4 and 5.5 min per sample, respectively. Our methods provide highly accurate measurements and high recovery levels for lipopeptides. At the same time, UPLC-MS provides the possibility to identify lipopeptides and their structural isoforms.

  8. Estimating phosphorus loss in runoff from manure and fertilizer for a phosphorus loss quantification tool.

    PubMed

    Vadas, P A; Good, L W; Moore, P A; Widman, N

    2009-01-01

    Nonpoint-source pollution of fresh waters by P is a concern because it contributes to accelerated eutrophication. Given the state of the science concerning agricultural P transport, a simple tool to quantify annual, field-scale P loss is a realistic goal. We developed new methods to predict annual dissolved P loss in runoff from surface-applied manures and fertilizers and validated the methods with data from 21 published field studies. We incorporated these manure and fertilizer P runoff loss methods into an annual, field-scale P loss quantification tool that estimates dissolved and particulate P loss in runoff from soil, manure, fertilizer, and eroded sediment. We validated the P loss tool using independent data from 28 studies that monitored P loss in runoff from a variety of agricultural land uses for at least 1 yr. Results demonstrated (i) that our new methods to estimate P loss from surface manure and fertilizer are an improvement over methods used in existing Indexes, and (ii) that it was possible to reliably quantify annual dissolved, sediment, and total P loss in runoff using relatively simple methods and readily available inputs. Thus, a P loss quantification tool that does not require greater degrees of complexity or input data than existing P Indexes could accurately predict P loss across a variety of management and fertilization practices, soil types, climates, and geographic locations. However, estimates of runoff and erosion are still needed that are accurate to a level appropriate for the intended use of the quantification tool.

  9. A single step reversed-phase high performance liquid chromatography separation of polar and non-polar lipids.

    PubMed

    Olsson, Petter; Holmbäck, Jan; Herslöf, Bengt

    2014-11-21

    This paper reports a simple chromatographic system to separate lipids classes as well as their molecular species. By the use of phenyl coated silica as stationary phase in combination with a simple mobile phase consisting of methanol and water, all tested lipid classes elute within 30 min. Furthermore, a method to accurately predict retention times of specific lipid components for this type of chromatography is presented. Common detection systems were used, namely evaporative light scattering detection (ELSD), charged aerosol detection (CAD), electrospray mass spectrometry (ESI-MS), and UV detection. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Harmonizing multiple methods for reconstructing historical potential and reference evapotranspiration

    USGS Publications Warehouse

    Belaineh, Getachew; Sumner, David; Carter, Edward; Clapp, David

    2013-01-01

    Potential evapotranspiration (PET) and reference evapotranspiration (RET) data are usually critical components of hydrologic analysis. Many different equations are available to estimate PET and RET. Most of these equations, such as the Priestley-Taylor and Penman- Monteith methods, rely on detailed meteorological data collected at ground-based weather stations. Few weather stations collect enough data to estimate PET or RET using one of the more complex evapotranspiration equations. Currently, satellite data integrated with ground meteorological data are used with one of these evapotranspiration equations to accurately estimate PET and RET. However, earlier than the last few decades, historical reconstructions of PET and RET needed for many hydrologic analyses are limited by the paucity of satellite data and of some types of ground data. Air temperature stands out as the most generally available meteorological ground data type over the last century. Temperature-based approaches used with readily available historical temperature data offer the potential for long period-of-record PET and RET historical reconstructions. A challenge is the inconsistency between the more accurate, but more data intensive, methods appropriate for more recent periods and the less accurate, but less data intensive, methods appropriate to the more distant past. In this study, multiple methods are harmonized in a seamless reconstruction of historical PET and RET by quantifying and eliminating the biases of the simple Hargreaves-Samani method relative to the more complex and accurate Priestley-Taylor and Penman-Monteith methods. This harmonization process is used to generate long-term, internally consistent, spatiotemporal databases of PET and RET.

  11. Rapid Classification and Identification of Multiple Microorganisms with Accurate Statistical Significance via High-Resolution Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Alves, Gelio; Wang, Guanghui; Ogurtsov, Aleksey Y.; Drake, Steven K.; Gucek, Marjan; Sacks, David B.; Yu, Yi-Kuo

    2018-06-01

    Rapid and accurate identification and classification of microorganisms is of paramount importance to public health and safety. With the advance of mass spectrometry (MS) technology, the speed of identification can be greatly improved. However, the increasing number of microbes sequenced is complicating correct microbial identification even in a simple sample due to the large number of candidates present. To properly untwine candidate microbes in samples containing one or more microbes, one needs to go beyond apparent morphology or simple "fingerprinting"; to correctly prioritize the candidate microbes, one needs to have accurate statistical significance in microbial identification. We meet these challenges by using peptide-centric representations of microbes to better separate them and by augmenting our earlier analysis method that yields accurate statistical significance. Here, we present an updated analysis workflow that uses tandem MS (MS/MS) spectra for microbial identification or classification. We have demonstrated, using 226 MS/MS publicly available data files (each containing from 2500 to nearly 100,000 MS/MS spectra) and 4000 additional MS/MS data files, that the updated workflow can correctly identify multiple microbes at the genus and often the species level for samples containing more than one microbe. We have also shown that the proposed workflow computes accurate statistical significances, i.e., E values for identified peptides and unified E values for identified microbes. Our updated analysis workflow MiCId, a freely available software for Microorganism Classification and Identification, is available for download at https://www.ncbi.nlm.nih.gov/CBBresearch/Yu/downloads.html.

  12. Rapid Classification and Identification of Multiple Microorganisms with Accurate Statistical Significance via High-Resolution Tandem Mass Spectrometry.

    PubMed

    Alves, Gelio; Wang, Guanghui; Ogurtsov, Aleksey Y; Drake, Steven K; Gucek, Marjan; Sacks, David B; Yu, Yi-Kuo

    2018-06-05

    Rapid and accurate identification and classification of microorganisms is of paramount importance to public health and safety. With the advance of mass spectrometry (MS) technology, the speed of identification can be greatly improved. However, the increasing number of microbes sequenced is complicating correct microbial identification even in a simple sample due to the large number of candidates present. To properly untwine candidate microbes in samples containing one or more microbes, one needs to go beyond apparent morphology or simple "fingerprinting"; to correctly prioritize the candidate microbes, one needs to have accurate statistical significance in microbial identification. We meet these challenges by using peptide-centric representations of microbes to better separate them and by augmenting our earlier analysis method that yields accurate statistical significance. Here, we present an updated analysis workflow that uses tandem MS (MS/MS) spectra for microbial identification or classification. We have demonstrated, using 226 MS/MS publicly available data files (each containing from 2500 to nearly 100,000 MS/MS spectra) and 4000 additional MS/MS data files, that the updated workflow can correctly identify multiple microbes at the genus and often the species level for samples containing more than one microbe. We have also shown that the proposed workflow computes accurate statistical significances, i.e., E values for identified peptides and unified E values for identified microbes. Our updated analysis workflow MiCId, a freely available software for Microorganism Classification and Identification, is available for download at https://www.ncbi.nlm.nih.gov/CBBresearch/Yu/downloads.html . Graphical Abstract ᅟ.

  13. Millimeter wave satellite communication studies. Results of the 1981 propagation modeling effort

    NASA Technical Reports Server (NTRS)

    Stutzman, W. L.; Tsolakis, A.; Dishman, W. K.

    1982-01-01

    Theoretical modeling associated with rain effects on millimeter wave propagation is detailed. Three areas of work are discussed. A simple model for prediction of rain attenuation is developed and evaluated. A method for computing scattering from single rain drops is presented. A complete multiple scattering model is described which permits accurate calculation of the effects on dual polarized signals passing through rain.

  14. Pre-Packaged Commercial PACE Financing Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallander, Michael

    The objective of this project was to demonstrate a more streamlined method for facilitating commercial property assessed clean energy (PACE) retrofits. The Recipient aimed to prove that energy efficiency performance of simple, pre-packaged technologies (e.g., lighting and heating, ventilation and air conditioning (HVAC)) can be accurately estimated without the need for a detailed energy audit. A successful project would inspire consumer confidence in undertaking cost-effective retrofits.

  15. A new method of time difference measurement: The time difference method by dual phase coincidence points detection

    NASA Technical Reports Server (NTRS)

    Zhou, Wei

    1993-01-01

    In the high accurate measurement of periodic signals, the greatest common factor frequency and its characteristics have special functions. A method of time difference measurement - the time difference method by dual 'phase coincidence points' detection is described. This method utilizes the characteristics of the greatest common factor frequency to measure time or phase difference between periodic signals. It can suit a very wide frequency range. Measurement precision and potential accuracy of several picoseconds were demonstrated with this new method. The instrument based on this method is very simple, and the demand for the common oscillator is low. This method and instrument can be used widely.

  16. Validated modified Lycopodium spore method development for standardisation of ingredients of an ayurvedic powdered formulation Shatavaryadi churna.

    PubMed

    Kumar, Puspendra; Jha, Shivesh; Naved, Tanveer

    2013-01-01

    Validated modified lycopodium spore method has been developed for simple and rapid quantification of herbal powdered drugs. Lycopodium spore method was performed on ingredients of Shatavaryadi churna, an ayurvedic formulation used as immunomodulator, galactagogue, aphrodisiac and rejuvenator. Estimation of diagnostic characters of each ingredient of Shatavaryadi churna individually was carried out. Microscopic determination, counting of identifying number, measurement of area, length and breadth of identifying characters were performed using Leica DMLS-2 microscope. The method was validated for intraday precision, linearity, specificity, repeatability, accuracy and system suitability, respectively. The method is simple, precise, sensitive, and accurate, and can be used for routine standardisation of raw materials of herbal drugs. This method gives the ratio of individual ingredients in the powdered drug so that any adulteration of genuine drug with its adulterant can be found out. The method shows very good linearity value between 0.988-0.999 for number of identifying character and area of identifying character. Percentage purity of the sample drug can be determined by using the linear equation of standard genuine drug.

  17. Development of a Simple RP-HPLC-UV Method for Determination of Azithromycin in Bulk and Pharmaceutical Dosage forms as an Alternative to the USP Method

    PubMed Central

    Ghari, Tayebeh; Kobarfard, Farzad; Mortazavi, Seyed Alireza

    2013-01-01

    The present study was designed to develop a simple, validated liquid chromatographic method for the analysis of azithromycin in bulk and pharmaceutical dosage forms using ultraviolet detector. The best stationary phase was determined as C18 column, 5 μm, 250 mm × 4.6 mm. Mobile phase was optimized to obtain a fast and selective separation of the drug. Flow rate was 1.5 mL/min, Wavelength was set at 210 nm and the volume of each injection was 500 μL. An isocratic methanol/buffer mobile phase at the ratio of 90:10 v/v gave the best separation and resolution. The proposed method was accurate, precise, sensitive, and linear over a wide range of concentration of azithromycin. The developed method has the advantage of using UV detector compared to the USP method in which electrochemical detector has been used. The validated method was successfully applied to the determination of azithromycin in bulk and pharmaceutical dosage forms. PMID:24250672

  18. Computer Vision Photogrammetry for Underwater Archaeological Site Recording in a Low-Visibility Environment

    NASA Astrophysics Data System (ADS)

    Van Damme, T.

    2015-04-01

    Computer Vision Photogrammetry allows archaeologists to accurately record underwater sites in three dimensions using simple twodimensional picture or video sequences, automatically processed in dedicated software. In this article, I share my experience in working with one such software package, namely PhotoScan, to record a Dutch shipwreck site. In order to demonstrate the method's reliability and flexibility, the site in question is reconstructed from simple GoPro footage, captured in low-visibility conditions. Based on the results of this case study, Computer Vision Photogrammetry compares very favourably to manual recording methods both in recording efficiency, and in the quality of the final results. In a final section, the significance of Computer Vision Photogrammetry is then assessed from a historical perspective, by placing the current research in the wider context of about half a century of successful use of Analytical and later Digital photogrammetry in the field of underwater archaeology. I conclude that while photogrammetry has been used in our discipline for several decades now, for various reasons the method was only ever used by a relatively small percentage of projects. This is likely to change in the near future since, compared to the `traditional' photogrammetry approaches employed in the past, today Computer Vision Photogrammetry is easier to use, more reliable and more affordable than ever before, while at the same time producing more accurate and more detailed three-dimensional results.

  19. Time accurate application of the MacCormack 2-4 scheme on massively parallel computers

    NASA Technical Reports Server (NTRS)

    Hudson, Dale A.; Long, Lyle N.

    1995-01-01

    Many recent computational efforts in turbulence and acoustics research have used higher order numerical algorithms. One popular method has been the explicit MacCormack 2-4 scheme. The MacCormack 2-4 scheme is second order accurate in time and fourth order accurate in space, and is stable for CFL's below 2/3. Current research has shown that the method can give accurate results but does exhibit significant Gibbs phenomena at sharp discontinuities. The impact of adding Jameson type second, third, and fourth order artificial viscosity was examined here. Category 2 problems, the nonlinear traveling wave and the Riemann problem, were computed using a CFL number of 0.25. This research has found that dispersion errors can be significantly reduced or nearly eliminated by using a combination of second and third order terms in the damping. Use of second and fourth order terms reduced the magnitude of dispersion errors but not as effectively as the second and third order combination. The program was coded using Thinking Machine's CM Fortran, a variant of Fortran 90/High Performance Fortran, and was executed on a 2K CM-200. Simple extrapolation boundary conditions were used for both problems.

  20. Radiologic evaluation of nonalcoholic fatty liver disease

    PubMed Central

    Lee, Seung Soo; Park, Seong Ho

    2014-01-01

    Nonalcoholic fatty liver disease (NAFLD) is a frequent cause of chronic liver diseases, ranging from simple steatosis to nonalcoholic steatohepatitis (NASH)-related liver cirrhosis. Although liver biopsy is still the gold standard for the diagnosis of NAFLD, especially for the diagnosis of NASH, imaging methods have been increasingly accepted as noninvasive alternatives to liver biopsy. Ultrasonography is a well-established and cost-effective imaging technique for the diagnosis of hepatic steatosis, especially for screening a large population at risk of NAFLD. Ultrasonography has a reasonable accuracy in detecting moderate-to-severe hepatic steatosis although it is less accurate for detecting mild hepatic steatosis, operator-dependent, and rather qualitative. Computed tomography is not appropriate for general population assessment of hepatic steatosis given its inaccuracy in detecting mild hepatic steatosis and potential radiation hazard. However, computed tomography may be effective in specific clinical situations, such as evaluation of donor candidates for hepatic transplantation. Magnetic resonance spectroscopy and magnetic resonance imaging are now regarded as the most accurate practical methods of measuring liver fat in clinical practice, especially for longitudinal follow-up of patients with NAFLD. Ultrasound elastography and magnetic resonance elastography are increasingly used to evaluate the degree of liver fibrosis in patients with NAFLD and to differentiate NASH from simple steatosis. This article will review current imaging methods used to evaluate hepatic steatosis, including the diagnostic accuracy, limitations, and practical applicability of each method. It will also briefly describe the potential role of elastography techniques in the evaluation of patients with NAFLD. PMID:24966609

  1. Correlated k-distribution method for radiative transfer in climate models: Application to effect of cirrus clouds on climate

    NASA Technical Reports Server (NTRS)

    Lacis, A. A.; Wang, W. C.; Hansen, J. E.

    1979-01-01

    A radiative transfer method appropriate for use in simple climate models and three dimensional global climate models was developed. It is fully interactive with climate changes, such as in the temperature-pressure profile, cloud distribution, and atmospheric composition, and it is accurate throughout the troposphere and stratosphere. The vertical inhomogeneity of the atmosphere is accounted for by assuming a correlation of gaseous k-distributions of different pressures and temperatures. Line-by-line calculations are made to demonstrate that The method is remarkably accurate. The method is then used in a one-dimensional radiative-convective climate model to study the effect of cirrus clouds on surface temperature. It is shown that an increase in cirrus cloud cover can cause a significant warming of the troposphere and the Earth's surface, by the mechanism of an enhanced green-house effect. The dependence of this phenomenon on cloud optical thickness, altitude, and latitude is investigated.

  2. High-speed engine/component performance assessment using exergy and thrust-based methods

    NASA Technical Reports Server (NTRS)

    Riggins, D. W.

    1996-01-01

    This investigation summarizes a comparative study of two high-speed engine performance assessment techniques based on energy (available work) and thrust-potential (thrust availability). Simple flow-fields utilizing Rayleigh heat addition and one-dimensional flow with friction are used to demonstrate the fundamental inability of conventional energy techniques to predict engine component performance, aid in component design, or accurately assess flow losses. The use of the thrust-based method on these same examples demonstrates its ability to yield useful information in all these categories. Energy and thrust are related and discussed from the stand-point of their fundamental thermodynamic and fluid dynamic definitions in order to explain the differences in information obtained using the two methods. The conventional definition of energy is shown to include work which is inherently unavailable to an aerospace Brayton engine. An engine-based energy is then developed which accurately accounts for this inherently unavailable work; performance parameters based on this quantity are then shown to yield design and loss information equivalent to the thrust-based method.

  3. Multiphase Interface Tracking with Fast Semi-Lagrangian Contouring.

    PubMed

    Li, Xiaosheng; He, Xiaowei; Liu, Xuehui; Zhang, Jian J; Liu, Baoquan; Wu, Enhua

    2016-08-01

    We propose a semi-Lagrangian method for multiphase interface tracking. In contrast to previous methods, our method maintains an explicit polygonal mesh, which is reconstructed from an unsigned distance function and an indicator function, to track the interface of arbitrary number of phases. The surface mesh is reconstructed at each step using an efficient multiphase polygonization procedure with precomputed stencils while the distance and indicator function are updated with an accurate semi-Lagrangian path tracing from the meshes of the last step. Furthermore, we provide an adaptive data structure, multiphase distance tree, to accelerate the updating of both the distance function and the indicator function. In addition, the adaptive structure also enables us to contour the distance tree accurately with simple bisection techniques. The major advantage of our method is that it can easily handle topological changes without ambiguities and preserve both the sharp features and the volume well. We will evaluate its efficiency, accuracy and robustness in the results part with several examples.

  4. Droplet Digital PCR-Based Chimerism Analysis for Primary Immunodeficiency Diseases.

    PubMed

    Okano, Tsubasa; Tsujita, Yuki; Kanegane, Hirokazu; Mitsui-Sekinaka, Kanako; Tanita, Kay; Miyamoto, Satoshi; Yeh, Tzu-Wen; Yamashita, Motoi; Terada, Naomi; Ogura, Yumi; Takagi, Masatoshi; Imai, Kohsuke; Nonoyama, Shigeaki; Morio, Tomohiro

    2018-04-01

    In the current study, we aimed to accurately evaluate donor/recipient or male/female chimerism in samples from patients who underwent hematopoietic stem cell transplantation (HSCT). We designed the droplet digital polymerase chain reaction (ddPCR) for SRY and RPP30 to detect the male/female chimerism. We also developed mutation-specific ddPCR for four primary immunodeficiency diseases. The accuracy of the male/female chimerism analysis using ddPCR was confirmed by comparing the results with those of conventional methods (fluorescence in situ hybridization and short tandem repeat-PCR) and evaluating dilution assays. In particular, we found that this method was useful for analyzing small samples. Thus, this method could be used with patient samples, especially to sorted leukocyte subpopulations, during the early post-transplant period. Four mutation-specific ddPCR accurately detected post-transplant chimerism. ddPCR-based male/female chimerism analysis and mutation-specific ddPCR were useful for all HSCT, and these simple methods contribute to following the post-transplant chimerism, especially in disease-specific small leukocyte fractions.

  5. Spectrophotometric Methods for the Determination of Sitagliptin and Vildagliptin in Bulk and Dosage Forms

    PubMed Central

    El-Bagary, Ramzia I.; Elkady, Ehab F.; Ayoub, Bassam M.

    2011-01-01

    Simple, accurate and precise spectrophotometric methods have been developed for the determination of sitagliptin and vildagliptin in bulk and dosage forms. The proposed methods are based on the charge transfer complexes of sitagliptin phosphate and vildagliptin with 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ), 7,7,8,8-tetracyanoquinodimethane (TCNQ) and tetrachloro-1,4-benzoquinone (p-chloranil). All the variables were studied to optimize the reactions conditions. For sitagliptin, Beer’s law was obeyed in the concentration ranges of 50-300 μg/ml, 20-120 μg/ml and 100-900 μg/ml with DDQ, TCNQ and p-chloranil, respectively. For vildagliptin, Beer’s law was obeyed in the concentration ranges of 50-300 μg/ml, 10-85 μg/ml and 50-350 μg/ml with DDQ, TCNQ and p-chloranil, respectively. The developed methods were validated and proved to be specific and accurate for the quality control of the cited drugs in pharmaceutical dosage forms. PMID:23675221

  6. Comparison of HPLC & spectrophotometric methods for estimation of antiretroviral drug content in pharmaceutical products.

    PubMed

    Hemanth Kumar, A K; Sudha, V; Swaminathan, Soumya; Ramachandran, Geetha

    2010-10-01

    Simple and reliable methods to estimate drugs in pharmaceutical products are needed. In most cases, antiretroviral drug estimations are performed using a HPLC method, requiring expensive equipment and trained technicians. A relatively simple and accurate method to estimate antiretroviral drugs in pharmaceutical preparations is by spectrophotometric method, which is cheap and simple to use as compared to HPLC. We undertook this study to standardise methods for estimation of nevirapine (NVP), lamivudine (3TC) and stavudine (d4T) in single tablets/capsules by HPLC and spectrophotometry and to compare the content of these drugs determined by both these methods. Twenty tablets/capsules of NVP, 3TC and d4T each were analysed for their drug content by HPLC and spectrophotometric methods. Suitably diluted drug solutions were run on HPLC fitted with a C18 column using UV detection at ambient temperature. The absorbance of the diluted drug solutions were read in a spectrophotometer at 300, 285 and 270 nm for NVP, 3TC and d4T respectively. Pure powders of the drugs were used to prepare calibration standards of known drug concentrations, which was set up with each assay. The inter-day variation (%) of standards for NVP, 3TC and d4T ranged from 2.5 to 6.7, 2.1 to 7.7 and 6.2 to 7.7, respectively by HPLC. The corresponding values by spectrophotometric method were 2.7 to 4.7, 4.2 to 7.2 and 3.8 to 6.0. The per cent variation between the HPLC and spectrophotometric methods ranged from 0.45 to 4.49 per cent, 0 to 4.98 per cent and 0.35 to 8.73 per cent for NVP, 3TC and d4T,respectively. The contents of NVP, 3TC and d4T in the tablets estimated by HPLC and spectrophotometric methods were similar, and the variation in the amount of these drugs estimated by HPLC and spectrophotometric methods was below 10 per cent. This suggests that the spectrophotometric method is as accurate as the HPLC method for estimation of NVP, 3TC and d4T in tablet/capsule. Hence laboratories that do not have HPLC equipment can also undertake these drug estimations using spectrophotometer.

  7. Stability-Derivative Determination from Flight Data

    NASA Technical Reports Server (NTRS)

    Holowicz, Chester H.; Holleman, Euclid C.

    1958-01-01

    A comprehensive discussion of the various factors affecting the determination of stability and control derivatives from flight data is presented based on the experience of the NASA High-Speed Flight Station. Factors relating to test techniques, determination of mass characteristics, instrumentation, and methods of analysis are discussed. For most longitudinal-stability-derivative analyses simple equations utilizing period and damping have been found to be as satisfactory as more comprehensive methods. The graphical time-vector method has been the basis of lateral-derivative analysis, although simple approximate methods can be useful If applied with caution. Control effectiveness has been generally obtained by relating the peak acceleration to the rapid control input, and consideration must be given to aerodynamic contributions if reasonable accuracy is to be realized.. Because of the many factors involved In the determination of stability derivatives, It is believed that the primary stability and control derivatives are probably accurate to within 10 to 25 percent, depending upon the specific derivative. Static-stability derivatives at low angle of attack show the greatest accuracy.

  8. Tenax extraction as a simple approach to improve environmental risk assessments.

    PubMed

    Harwood, Amanda D; Nutile, Samuel A; Landrum, Peter F; Lydy, Michael J

    2015-07-01

    It is well documented that using exhaustive chemical extractions is not an effective means of assessing exposure of hydrophobic organic compounds in sediments and that bioavailability-based techniques are an improvement over traditional methods. One technique that has shown special promise as a method for assessing the bioavailability of hydrophobic organic compounds in sediment is the use of Tenax-extractable concentrations. A 6-h or 24-h single-point Tenax-extractable concentration correlates to both bioaccumulation and toxicity. This method has demonstrated effectiveness for several hydrophobic organic compounds in various organisms under both field and laboratory conditions. In addition, a Tenax bioaccumulation model was developed for multiple compounds relating 24-h Tenax-extractable concentrations to oligochaete tissue concentrations exposed in both the laboratory and field. This model has demonstrated predictive capacity for additional compounds and species. Use of Tenax-extractable concentrations to estimate exposure is rapid, simple, straightforward, and relatively inexpensive, as well as accurate. Therefore, this method would be an invaluable tool if implemented in risk assessments. © 2015 SETAC.

  9. A machine learning method for fast and accurate characterization of depth-of-interaction gamma cameras

    NASA Astrophysics Data System (ADS)

    Pedemonte, Stefano; Pierce, Larry; Van Leemput, Koen

    2017-11-01

    Measuring the depth-of-interaction (DOI) of gamma photons enables increasing the resolution of emission imaging systems. Several design variants of DOI-sensitive detectors have been recently introduced to improve the performance of scanners for positron emission tomography (PET). However, the accurate characterization of the response of DOI detectors, necessary to accurately measure the DOI, remains an unsolved problem. Numerical simulations are, at the state of the art, imprecise, while measuring directly the characteristics of DOI detectors experimentally is hindered by the impossibility to impose the depth-of-interaction in an experimental set-up. In this article we introduce a machine learning approach for extracting accurate forward models of gamma imaging devices from simple pencil-beam measurements, using a nonlinear dimensionality reduction technique in combination with a finite mixture model. The method is purely data-driven, not requiring simulations, and is applicable to a wide range of detector types. The proposed method was evaluated both in a simulation study and with data acquired using a monolithic gamma camera designed for PET (the cMiCE detector), demonstrating the accurate recovery of the DOI characteristics. The combination of the proposed calibration technique with maximum- a posteriori estimation of the coordinates of interaction provided a depth resolution of  ≈1.14 mm for the simulated PET detector and  ≈1.74 mm for the cMiCE detector. The software and experimental data are made available at http://occiput.mgh.harvard.edu/depthembedding/.

  10. HPTLC Determination of Artemisinin and Its Derivatives in Bulk and Pharmaceutical Dosage

    NASA Astrophysics Data System (ADS)

    Agarwal, Suraj P.; Ahuja, Shipra

    A simple, selective, accurate, and precise high-performance thin-layer chromatographic (HPTLC) method has been established and validated for the analysis of artemisinin and its derivatives (artesunate, artemether, and arteether) in the bulk drugs and formulations. The artemisinin, artesunate, artemether, and arteether were separated on aluminum-backed silica gel 60 F254 plates with toluene:ethyl acetate (10:1), toluene: ethyl acetate: acetic acid (2:8:0.2), toluene:butanol (10:1), and toluene:dichloro methane (0.5:10) mobile phase, respectively. The linear detector response for concentrations between 100 and 600 ng/spot showed good linear relationship with r value 0.9967, 0.9989, 0.9981 and 0.9989 for artemisinin, artesunate, artemether, and arteether, respectively. Statistical analysis proves that the method is precise, accurate, and reproducible and hence can be employed for the routine analysis.

  11. An instrumental electrode model for solving EIT forward problems.

    PubMed

    Zhang, Weida; Li, David

    2014-10-01

    An instrumental electrode model (IEM) capable of describing the performance of electrical impedance tomography (EIT) systems in the MHz frequency range has been proposed. Compared with the commonly used Complete Electrode Model (CEM), which assumes ideal front-end interfaces, the proposed model considers the effects of non-ideal components in the front-end circuits. This introduces an extra boundary condition in the forward model and offers a more accurate modelling for EIT systems. We have demonstrated its performance using simple geometry structures and compared the results with the CEM and full Maxwell methods. The IEM can provide a significantly more accurate approximation than the CEM in the MHz frequency range, where the full Maxwell methods are favoured over the quasi-static approximation. The improved electrode model will facilitate the future characterization and front-end design of real-world EIT systems.

  12. A novel method to calibrate DOI function of a PET detector with a dual-ended-scintillator readout.

    PubMed

    Shao, Yiping; Yao, Rutao; Ma, Tianyu

    2008-12-01

    The detection of depth-of-interaction (DOI) is a critical detector capability to improve the PET spatial resolution uniformity across the field-of-view and will significantly enhance, in particular, small bore system performance for brain, breast, and small animal imaging. One promising technique of DOI detection is to use dual-ended-scintillator readout that uses two photon sensors to detect scintillation light from both ends of a scintillator array and estimate DOI based on the ratio of signals (similar to Anger logic). This approach needs a careful DOI function calibration to establish accurate relationship between DOI and signal ratios, and to recalibrate if the detection condition is shifted due to the drift of sensor gain, bias variations, or degraded optical coupling, etc. However, the current calibration method that uses coincident events to locate interaction positions inside a single scintillator crystal has severe drawbacks, such as complicated setup, long and repetitive measurements, and being prone to errors from various possible misalignments among the source and detector components. This method is also not practically suitable to calibrate multiple DOI functions of a crystal array. To solve these problems, a new method has been developed that requires only a uniform flood source to irradiate a crystal array without the need to locate the interaction positions, and calculates DOI functions based solely on the uniform probability distribution of interactions over DOI positions without knowledge or assumption of detector responses. Simulation and experiment have been studied to validate the new method, and the results show that the new method, with a simple setup and one single measurement, can provide consistent and accurate DOI functions for the entire array of multiple scintillator crystals. This will enable an accurate, simple, and practical DOI function calibration for the PET detectors based on the design of dual-ended-scintillator readout. In addition, the new method can be generally applied to calibrating other types of detectors that use the similar dual-ended readout to acquire the radiation interaction position.

  13. A novel method to calibrate DOI function of a PET detector with a dual-ended-scintillator readout

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shao Yiping; Yao Rutao; Ma Tianyu

    The detection of depth-of-interaction (DOI) is a critical detector capability to improve the PET spatial resolution uniformity across the field-of-view and will significantly enhance, in particular, small bore system performance for brain, breast, and small animal imaging. One promising technique of DOI detection is to use dual-ended-scintillator readout that uses two photon sensors to detect scintillation light from both ends of a scintillator array and estimate DOI based on the ratio of signals (similar to Anger logic). This approach needs a careful DOI function calibration to establish accurate relationship between DOI and signal ratios, and to recalibrate if the detectionmore » condition is shifted due to the drift of sensor gain, bias variations, or degraded optical coupling, etc. However, the current calibration method that uses coincident events to locate interaction positions inside a single scintillator crystal has severe drawbacks, such as complicated setup, long and repetitive measurements, and being prone to errors from various possible misalignments among the source and detector components. This method is also not practically suitable to calibrate multiple DOI functions of a crystal array. To solve these problems, a new method has been developed that requires only a uniform flood source to irradiate a crystal array without the need to locate the interaction positions, and calculates DOI functions based solely on the uniform probability distribution of interactions over DOI positions without knowledge or assumption of detector responses. Simulation and experiment have been studied to validate the new method, and the results show that the new method, with a simple setup and one single measurement, can provide consistent and accurate DOI functions for the entire array of multiple scintillator crystals. This will enable an accurate, simple, and practical DOI function calibration for the PET detectors based on the design of dual-ended-scintillator readout. In addition, the new method can be generally applied to calibrating other types of detectors that use the similar dual-ended readout to acquire the radiation interaction position.« less

  14. Model independent approach to the single photoelectron calibration of photomultiplier tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saldanha, R.; Grandi, L.; Guardincerri, Y.

    2017-08-01

    The accurate calibration of photomultiplier tubes is critical in a wide variety of applications in which it is necessary to know the absolute number of detected photons or precisely determine the resolution of the signal. Conventional calibration methods rely on fitting the photomultiplier response to a low intensity light source with analytical approximations to the single photoelectron distribution, often leading to biased estimates due to the inability to accurately model the full distribution, especially at low charge values. In this paper we present a simple statistical method to extract the relevant single photoelectron calibration parameters without making any assumptions aboutmore » the underlying single photoelectron distribution. We illustrate the use of this method through the calibration of a Hamamatsu R11410 photomultiplier tube and study the accuracy and precision of the method using Monte Carlo simulations. The method is found to have significantly reduced bias compared to conventional methods and works under a wide range of light intensities, making it suitable for simultaneously calibrating large arrays of photomultiplier tubes.« less

  15. Efficient quantification of water content in edible oils by headspace gas chromatography with vapour phase calibration.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2018-06-01

    An automated and accurate headspace gas chromatographic (HS-GC) technique was investigated for rapidly quantifying water content in edible oils. In this method, multiple headspace extraction (MHE) procedures were used to analyse the integrated water content from the edible oil sample. A simple vapour phase calibration technique with an external vapour standard was used to calibrate both the water content in the gas phase and the total weight of water in edible oil sample. After that the water in edible oils can be quantified. The data showed that the relative standard deviation of the present HS-GC method in the precision test was less than 1.13%, the relative differences between the new method and a reference method (i.e. the oven-drying method) were no more than 1.62%. The present HS-GC method is automated, accurate, efficient, and can be a reliable tool for quantifying water content in edible oil related products and research. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  16. Detection of Adulterated Vegetable Oils Containing Waste Cooking Oils Based on the Contents and Ratios of Cholesterol, β-Sitosterol, and Campesterol by Gas Chromatography/Mass Spectrometry.

    PubMed

    Zhao, Haixiang; Wang, Yongli; Xu, Xiuli; Ren, Heling; Li, Li; Xiang, Li; Zhong, Weike

    2015-01-01

    A simple and accurate authentication method for the detection of adulterated vegetable oils that contain waste cooking oil (WCO) was developed. This method is based on the determination of cholesterol, β-sitosterol, and campesterol in vegetable oils and WCO by GC/MS without any derivatization. A total of 148 samples involving 12 types of vegetable oil and WCO were analyzed. According to the results, the contents and ratios of cholesterol, β-sitosterol, and campesterol were found to be criteria for detecting vegetable oils adulterated with WCO. This method could accurately detect adulterated vegetable oils containing 5% refined WCO. The developed method has been successfully applied to multilaboratory analysis of 81 oil samples. Seventy-five samples were analyzed correctly, and only six adulterated samples could not be detected. This method could not yet be used for detection of vegetable oils adulterated with WCO that are used for frying non-animal foods. It provides a quick method for detecting adulterated edible vegetable oils containing WCO.

  17. Evaluation of automated threshold selection methods for accurately sizing microscopic fluorescent cells by image analysis.

    PubMed Central

    Sieracki, M E; Reichenbach, S E; Webb, K L

    1989-01-01

    The accurate measurement of bacterial and protistan cell biomass is necessary for understanding their population and trophic dynamics in nature. Direct measurement of fluorescently stained cells is often the method of choice. The tedium of making such measurements visually on the large numbers of cells required has prompted the use of automatic image analysis for this purpose. Accurate measurements by image analysis require an accurate, reliable method of segmenting the image, that is, distinguishing the brightly fluorescing cells from a dark background. This is commonly done by visually choosing a threshold intensity value which most closely coincides with the outline of the cells as perceived by the operator. Ideally, an automated method based on the cell image characteristics should be used. Since the optical nature of edges in images of light-emitting, microscopic fluorescent objects is different from that of images generated by transmitted or reflected light, it seemed that automatic segmentation of such images may require special considerations. We tested nine automated threshold selection methods using standard fluorescent microspheres ranging in size and fluorescence intensity and fluorochrome-stained samples of cells from cultures of cyanobacteria, flagellates, and ciliates. The methods included several variations based on the maximum intensity gradient of the sphere profile (first derivative), the minimum in the second derivative of the sphere profile, the minimum of the image histogram, and the midpoint intensity. Our results indicated that thresholds determined visually and by first-derivative methods tended to overestimate the threshold, causing an underestimation of microsphere size. The method based on the minimum of the second derivative of the profile yielded the most accurate area estimates for spheres of different sizes and brightnesses and for four of the five cell types tested. A simple model of the optical properties of fluorescing objects and the video acquisition system is described which explains how the second derivative best approximates the position of the edge. Images PMID:2516431

  18. A simple method for determining stress intensity factors for a crack in bi-material interface

    NASA Astrophysics Data System (ADS)

    Morioka, Yuta

    Because of violently oscillating nature of stress and displacement fields near the crack tip, it is difficult to obtain stress intensity factors for a crack between two dis-similar media. For a crack in a homogeneous medium, it is a common practice to find stress intensity factors through strain energy release rates. However, individual strain energy release rates do not exist for bi-material interface crack. Hence it is necessary to find alternative methods to evaluate stress intensity factors. Several methods have been proposed in the past. However they involve mathematical complexity and sometimes require additional finite element analysis. The purpose of this research is to develop a simple method to find stress intensity factors in bi-material interface cracks. A finite element based projection method is proposed in the research. It is shown that the projection method yields very accurate stress intensity factors for a crack in isotropic and anisotropic bi-material interfaces. The projection method is also compared to displacement ratio method and energy method proposed by other authors. Through comparison it is found that projection method is much simpler to apply with its accuracy comparable to that of displacement ratio method.

  19. A novel method for calculating the energy barriers for carbon diffusion in ferrite under heterogeneous stress

    NASA Astrophysics Data System (ADS)

    Tchitchekova, Deyana S.; Morthomas, Julien; Ribeiro, Fabienne; Ducher, Roland; Perez, Michel

    2014-07-01

    A novel method for accurate and efficient evaluation of the change in energy barriers for carbon diffusion in ferrite under heterogeneous stress is introduced. This method, called Linear Combination of Stress States, is based on the knowledge of the effects of simple stresses (uniaxial or shear) on these diffusion barriers. Then, it is assumed that the change in energy barriers under a complex stress can be expressed as a linear combination of these already known simple stress effects. The modifications of energy barriers by either uniaxial traction/compression and shear stress are determined by means of atomistic simulations with the Climbing Image-Nudge Elastic Band method and are stored as a set of functions. The results of this method are compared to the predictions of anisotropic elasticity theory. It is shown that, linear anisotropic elasticity fails to predict the correct energy barrier variation with stress (especially with shear stress) whereas the proposed method provides correct energy barrier variation for stresses up to ˜3 GPa. This study provides a basis for the development of multiscale models of diffusion under non-uniform stress.

  20. Comparison of Two Simplification Methods for Shoreline Extraction from Digital Orthophoto Images

    NASA Astrophysics Data System (ADS)

    Bayram, B.; Sen, A.; Selbesoglu, M. O.; Vārna, I.; Petersons, P.; Aykut, N. O.; Seker, D. Z.

    2017-11-01

    The coastal ecosystems are very sensitive to external influences. Coastal resources such as sand dunes, coral reefs and mangroves has vital importance to prevent coastal erosion. Human based effects also threats the coastal areas. Therefore, the change of coastal areas should be monitored. Up-to-date, accurate shoreline information is indispensable for coastal managers and decision makers. Remote sensing and image processing techniques give a big opportunity to obtain reliable shoreline information. In the presented study, NIR bands of seven 1:5000 scaled digital orthophoto images of Riga Bay-Latvia have been used. The Object-oriented Simple Linear Clustering method has been utilized to extract shoreline of Riga Bay. Bend and Douglas-Peucker methods have been used to simplify the extracted shoreline to test the effect of both methods. Photogrammetrically digitized shoreline has been taken as reference data to compare obtained results. The accuracy assessment has been realised by Digital Shoreline Analysis tool. As a result, the achieved shoreline by the Bend method has been found closer to the extracted shoreline with Simple Linear Clustering method.

  1. Machine learning methods for locating re-entrant drivers from electrograms in a model of atrial fibrillation

    NASA Astrophysics Data System (ADS)

    McGillivray, Max Falkenberg; Cheng, William; Peters, Nicholas S.; Christensen, Kim

    2018-04-01

    Mapping resolution has recently been identified as a key limitation in successfully locating the drivers of atrial fibrillation (AF). Using a simple cellular automata model of AF, we demonstrate a method by which re-entrant drivers can be located quickly and accurately using a collection of indirect electrogram measurements. The method proposed employs simple, out-of-the-box machine learning algorithms to correlate characteristic electrogram gradients with the displacement of an electrogram recording from a re-entrant driver. Such a method is less sensitive to local fluctuations in electrical activity. As a result, the method successfully locates 95.4% of drivers in tissues containing a single driver, and 95.1% (92.6%) for the first (second) driver in tissues containing two drivers of AF. Additionally, we demonstrate how the technique can be applied to tissues with an arbitrary number of drivers. In its current form, the techniques presented are not refined enough for a clinical setting. However, the methods proposed offer a promising path for future investigations aimed at improving targeted ablation for AF.

  2. A novel method for calculating the energy barriers for carbon diffusion in ferrite under heterogeneous stress.

    PubMed

    Tchitchekova, Deyana S; Morthomas, Julien; Ribeiro, Fabienne; Ducher, Roland; Perez, Michel

    2014-07-21

    A novel method for accurate and efficient evaluation of the change in energy barriers for carbon diffusion in ferrite under heterogeneous stress is introduced. This method, called Linear Combination of Stress States, is based on the knowledge of the effects of simple stresses (uniaxial or shear) on these diffusion barriers. Then, it is assumed that the change in energy barriers under a complex stress can be expressed as a linear combination of these already known simple stress effects. The modifications of energy barriers by either uniaxial traction/compression and shear stress are determined by means of atomistic simulations with the Climbing Image-Nudge Elastic Band method and are stored as a set of functions. The results of this method are compared to the predictions of anisotropic elasticity theory. It is shown that, linear anisotropic elasticity fails to predict the correct energy barrier variation with stress (especially with shear stress) whereas the proposed method provides correct energy barrier variation for stresses up to ∼3 GPa. This study provides a basis for the development of multiscale models of diffusion under non-uniform stress.

  3. Evaporation estimation of rift valley lakes: comparison of models.

    PubMed

    Melesse, Assefa M; Abtew, Wossenu; Dessalegne, Tibebe

    2009-01-01

    Evapotranspiration (ET) accounts for a substantial amount of the water flux in the arid and semi-arid regions of the World. Accurate estimation of ET has been a challenge for hydrologists, mainly because of the spatiotemporal variability of the environmental and physical parameters governing the latent heat flux. In addition, most available ET models depend on intensive meteorological information for ET estimation. Such data are not available at the desired spatial and temporal scales in less developed and remote parts of the world. This limitation has necessitated the development of simple models that are less data intensive and provide ET estimates with acceptable level of accuracy. Remote sensing approach can also be applied to large areas where meteorological data are not available and field scale data collection is costly, time consuming and difficult. In areas like the Rift Valley regions of Ethiopia, the applicability of the Simple Method (Abtew Method) of lake evaporation estimation and surface energy balance approach using remote sensing was studied. The Simple Method and a remote sensing-based lake evaporation estimates were compared to the Penman, Energy balance, Pan, Radiation and Complementary Relationship Lake Evaporation (CRLE) methods applied in the region. Results indicate a good correspondence of the models outputs to that of the above methods. Comparison of the 1986 and 2000 monthly lake ET from the Landsat images to the Simple and Penman Methods show that the remote sensing and surface energy balance approach is promising for large scale applications to understand the spatial variation of the latent heat flux.

  4. A simple and low-cost biofilm quantification method using LED and CMOS image sensor.

    PubMed

    Kwak, Yeon Hwa; Lee, Junhee; Lee, Junghoon; Kwak, Soo Hwan; Oh, Sangwoo; Paek, Se-Hwan; Ha, Un-Hwan; Seo, Sungkyu

    2014-12-01

    A novel biofilm detection platform, which consists of a cost-effective red, green, and blue light-emitting diode (RGB LED) as a light source and a lens-free CMOS image sensor as a detector, is designed. This system can measure the diffraction patterns of cells from their shadow images, and gather light absorbance information according to the concentration of biofilms through a simple image processing procedure. Compared to a bulky and expensive commercial spectrophotometer, this platform can provide accurate and reproducible biofilm concentration detection and is simple, compact, and inexpensive. Biofilms originating from various bacterial strains, including Pseudomonas aeruginosa (P. aeruginosa), were tested to demonstrate the efficacy of this new biofilm detection approach. The results were compared with the results obtained from a commercial spectrophotometer. To utilize a cost-effective light source (i.e., an LED) for biofilm detection, the illumination conditions were optimized. For accurate and reproducible biofilm detection, a simple, custom-coded image processing algorithm was developed and applied to a five-megapixel CMOS image sensor, which is a cost-effective detector. The concentration of biofilms formed by P. aeruginosa was detected and quantified by varying the indole concentration, and the results were compared with the results obtained from a commercial spectrophotometer. The correlation value of the results from those two systems was 0.981 (N = 9, P < 0.01) and the coefficients of variation (CVs) were approximately threefold lower at the CMOS image-sensor platform. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Validation of different spectrophotometric methods for determination of vildagliptin and metformin in binary mixture

    NASA Astrophysics Data System (ADS)

    Abdel-Ghany, Maha F.; Abdel-Aziz, Omar; Ayad, Miriam F.; Tadros, Mariam M.

    New, simple, specific, accurate, precise and reproducible spectrophotometric methods have been developed and subsequently validated for determination of vildagliptin (VLG) and metformin (MET) in binary mixture. Zero order spectrophotometric method was the first method used for determination of MET in the range of 2-12 μg mL-1 by measuring the absorbance at 237.6 nm. The second method was derivative spectrophotometric technique; utilized for determination of MET at 247.4 nm, in the range of 1-12 μg mL-1. Derivative ratio spectrophotometric method was the third technique; used for determination of VLG in the range of 4-24 μg mL-1 at 265.8 nm. Fourth and fifth methods adopted for determination of VLG in the range of 4-24 μg mL-1; were ratio subtraction and mean centering spectrophotometric methods, respectively. All the results were statistically compared with the reported methods, using one-way analysis of variance (ANOVA). The developed methods were satisfactorily applied to analysis of the investigated drugs and proved to be specific and accurate for quality control of them in pharmaceutical dosage forms.

  6. A flux monitoring method for easy and accurate flow rate measurement in pressure-driven flows.

    PubMed

    Siria, Alessandro; Biance, Anne-Laure; Ybert, Christophe; Bocquet, Lydéric

    2012-03-07

    We propose a low-cost and versatile method to measure flow rate in microfluidic channels under pressure-driven flows, thereby providing a simple characterization of the hydrodynamic permeability of the system. The technique is inspired by the current monitoring method usually employed to characterize electro-osmotic flows, and makes use of the measurement of the time-dependent electric resistance inside the channel associated with a moving salt front. We have successfully tested the method in a micrometer-size channel, as well as in a complex microfluidic channel with a varying cross-section, demonstrating its ability in detecting internal shape variations.

  7. Angiotensin-converting enzyme insertion/deletion polymorphism genotyping error: the cause and a possible solution to the problem.

    PubMed

    Saracevic, Andrea; Simundic, Ana-Maria; Celap, Ivana; Luzanic, Valentina

    2013-07-01

    Rigat and colleagues were the first ones to develop a rapid PCR-based assay for identifying the angiotensin converting enzyme insertion/deletion (I/D) polymorphism. Due to a big difference between the length of the wild-type and mute alleles the PCR method is prone to mistyping because of preferential amplification of the D allele causing depicting I/D heterozygotes as D/D homozygotes. The aim of this study was to investigate whether this preferential amplification can be repressed by amplifying a longer DNA fragment in a so called Long PCR protocol. We also aimed to compare the results of genotyping using five different PCR protocols and to estimate the mistyping rate. The study included 200 samples which were genotyped using standard method used in our laboratory, a stepdown PCR, PCR protocol with the inclusion of 4 % DMSO, PCR with the use of insertion specific primers and new Long PCR method. The results of this study have shown that accurate ACE I/D polymorphism genotyping can be accomplished with the standard and the Long PCR method. Also, as of our results, accurate ACE I/D polymorphism genotyping can be accomplished regardless of the method used. Therefore, if the standard method is optimized more cautiously, accurate results can be obtained by this simple, inexpensive and rapid PCR protocol.

  8. Accuracy-enhanced constitutive parameter identification using virtual fields method and special stereo-digital image correlation

    NASA Astrophysics Data System (ADS)

    Zhang, Zhongya; Pan, Bing; Grédiac, Michel; Song, Weidong

    2018-04-01

    The virtual fields method (VFM) is generally used with two-dimensional digital image correlation (2D-DIC) or grid method (GM) for identifying constitutive parameters. However, when small out-of-plane translation/rotation occurs to the test specimen, 2D-DIC and GM are prone to yield inaccurate measurements, which further lessen the accuracy of the parameter identification using VFM. In this work, an easy-to-implement but effective "special" stereo-DIC (SS-DIC) method is proposed for accuracy-enhanced VFM identification. The SS-DIC can not only deliver accurate deformation measurement without being affected by unavoidable out-of-plane movement/rotation of a test specimen, but can also ensure evenly distributed calculation data in space, which leads to simple data processing. Based on the accurate kinematics fields with evenly distributed measured points determined by SS-DIC method, constitutive parameters can be identified by VFM with enhanced accuracy. Uniaxial tensile tests of a perforated aluminum plate and pure shear tests of a prismatic aluminum specimen verified the effectiveness and accuracy of the proposed method. Experimental results show that the constitutive parameters identified by VFM using SS-DIC are more accurate and stable than those identified by VFM using 2D-DIC. It is suggested that the proposed SS-DIC can be used as a standard measuring tool for mechanical identification using VFM.

  9. Neural Network Design on the SRC-6 Reconfigurable Computer

    DTIC Science & Technology

    2006-12-01

    fingerprint identification. In this field, automatic identification methods are used to save time, especially for the purpose of fingerprint matching in...grid widths and lengths and therefore was useful in producing an accurate canvas with which to create sample training images. The added benefit of...tools available free of charge and readily accessible on the computer, it was simple to design bitmap data files visually on a canvas and then

  10. A Time-of-Flight Method to Measure the Speed of Sound Using a Stereo Sound Card

    ERIC Educational Resources Information Center

    Carvalho, Carlos C.; dos Santos, J. M. B. Lopes; Marques, M. B.

    2008-01-01

    Most homes in developed countries have a sophisticated data acquisition board, namely the PC sound board. Designed to be able to reproduce CD-quality stereo sound, it must have a sampling rate of at least 44 kHz and have very accurate timing between the two stereo channels. With a very simple adaptation of a pair of regular PC microphones, a…

  11. Diazo processing of LANDSAT imagery: A low-cost instructional technique

    NASA Technical Reports Server (NTRS)

    Lusch, D. P.

    1981-01-01

    Diazo processing of LANDSAT imagery is a relatively simple and cost effective method of producing enhanced renditions of the visual LANDSAT products. This technique is capable of producing a variety of image enhancements which have value in a teaching laboratory environment. Additionally, with the appropriate equipment, applications research which relys on accurate and repeatable results is possible. Exposure and development equipment options, diazo materials, and enhancement routines are discussed.

  12. Using a Video Camera to Measure the Radius of the Earth

    ERIC Educational Resources Information Center

    Carroll, Joshua; Hughes, Stephen

    2013-01-01

    A simple but accurate method for measuring the Earth's radius using a video camera is described. A video camera was used to capture a shadow rising up the wall of a tall building at sunset. A free program called ImageJ was used to measure the time it took the shadow to rise a known distance up the building. The time, distance and length of…

  13. Simple Parametric Model for Intensity Calibration of Cassini Composite Infrared Spectrometer Data

    NASA Technical Reports Server (NTRS)

    Brasunas, J.; Mamoutkine, A.; Gorius, N.

    2016-01-01

    Accurate intensity calibration of a linear Fourier-transform spectrometer typically requires the unknown science target and the two calibration targets to be acquired under identical conditions. We present a simple model suitable for vector calibration that enables accurate calibration via adjustments of measured spectral amplitudes and phases when these three targets are recorded at different detector or optics temperatures. Our model makes calibration more accurate both by minimizing biases due to changing instrument temperatures that are always present at some level and by decreasing estimate variance through incorporating larger averages of science and calibration interferogram scans.

  14. Accurate screening for insulin resistance in PCOS women using fasting insulin concentrations.

    PubMed

    Lunger, Fabian; Wildt, Ludwig; Seeber, Beata

    2013-06-01

    The aims of this cross-sectional study were to evaluate the relative agreement of both static and dynamic methods of diagnosing IR in women with polycystic ovary syndrome (PCOS) and to suggest a simple screening method for IR. All participants underwent serial blood draws for hormonal profiling and lipid assessment, a 3 h, 75 g load oral glucose tolerance test (OGTT) with every 15 min measurements of glucose and insulin, and an ACTH stimulation test. The prevalence of IR ranged from 12.2% to 60.5%, depending on the IR index used. Based on largest area under the curve on receiver operating curve (ROC) analyses, the dynamic indices outperformed the static indices with glucose to insulin ratio and fasting insulin (fInsulin) demonstrating the best diagnostic properties. Applying two cut-offs representing fInsulin extremes (<7 and >13 mIU/l, respectively) gave the diagnosis in 70% of the patients with high accuracy. Currently utilized indices for assessing IR give highly variable results in women with PCOS. The most accurate indices based on dynamic testing can be time-consuming and labor-intensive. We suggest the use of fInsulin as a simple screening test, which can reduce the number of OGTTs needed to routinely assess insulin resistance in women with PCOS.

  15. A Simple Endoscopic Technique for Measuring the Cross-Sectional Area of the Upper Airway in a Rabbit Model.

    PubMed

    Wistermayer, Paul R; McIlwain, Wesley R; Ieronimakis, Nicholas; Rogers, Derek J

    2018-04-01

    Validate an accurate and reproducible method of measuring the cross-sectional area (CSA) of the upper airway. This is a prospective animal study done at a tertiary care medical treatment facility. Control images were obtained using endotracheal tubes of varying sizes. In vivo images were obtained from various timepoints of a concurrent study on subglottic stenosis. Using a 0° rod telescope, an instrument was placed at the level of interest, and a photo was obtained. Three independent and blinded raters then measured the CSA of the narrowest portion of the airway using open source image analysis software. Each blinded rater measured the CSA of 79 photos. The t testing to assess for accuracy showed no difference between measured and known CSAs of the control images ( P = .86), with an average error of 1.5% (SD = 5.5%). All intraclass correlation (ICC) values for intrarater agreement showed excellent agreement (ICC > .75). Interrater reliability among all raters in control (ICC = .975; 95% CI, .817-.995) and in vivo (ICC = .846;, 95% CI, .780-.896) images showed excellent agreement. We validate a simple, accurate, and reproducible method of measuring the CSA of the airway that can be used in a clinical or research setting.

  16. Shape-based reconstruction for transrectal diffuse optical tomography monitoring of photothermal focal therapy of prostate cancer: simulation studies

    NASA Astrophysics Data System (ADS)

    Weersink, Robert A.; Chaudhary, Sahil; Mayo, Kenwrick; He, Jie; Wilson, Brian C.

    2017-04-01

    We develop and demonstrate a simple shape-based approach for diffuse optical tomographic reconstruction of coagulative lesions generated during interstitial photothermal therapy (PTT) of the prostate. The shape-based reconstruction assumes a simple ellipsoid shape, matching the general dimensions of a cylindrical diffusing fiber used for light delivery in current clinical studies of PTT in focal prostate cancer. The specific requirement is to accurately define the border between the photothermal lesion and native tissue as the photothermal lesion grows, with an accuracy of ≤1 mm, so treatment can be terminated before there is damage to the rectal wall. To demonstrate the feasibility of the shape-based diffuse optical tomography reconstruction, simulated data were generated based on forward calculations in known geometries that include the prostate, rectum, and lesions of varying dimensions. The only source of optical contrast between the lesion and prostate was increased scattering in the lesion, as is typically observed with coagulation. With noise added to these forward calculations, lesion dimensions were reconstructed using the shape-based method. This approach for reconstruction is shown to be feasible and sufficiently accurate for lesions that are within 4 mm from the rectal wall. The method was also robust for irregularly shaped lesions.

  17. A simple mass-conserved level set method for simulation of multiphase flows

    NASA Astrophysics Data System (ADS)

    Yuan, H.-Z.; Shu, C.; Wang, Y.; Shu, S.

    2018-04-01

    In this paper, a modified level set method is proposed for simulation of multiphase flows with large density ratio and high Reynolds number. The present method simply introduces a source or sink term into the level set equation to compensate the mass loss or offset the mass increase. The source or sink term is derived analytically by applying the mass conservation principle with the level set equation and the continuity equation of flow field. Since only a source term is introduced, the application of the present method is as simple as the original level set method, but it can guarantee the overall mass conservation. To validate the present method, the vortex flow problem is first considered. The simulation results are compared with those from the original level set method, which demonstrates that the modified level set method has the capability of accurately capturing the interface and keeping the mass conservation. Then, the proposed method is further validated by simulating the Laplace law, the merging of two bubbles, a bubble rising with high density ratio, and Rayleigh-Taylor instability with high Reynolds number. Numerical results show that the mass is a well-conserved by the present method.

  18. Adulteration of Ginkgo biloba products and a simple method to improve its detection.

    PubMed

    Wohlmuth, Hans; Savage, Kate; Dowell, Ashley; Mouatt, Peter

    2014-05-15

    Extracts of ginkgo (Ginkgo biloba) leaf are widely available worldwide in herbal medicinal products, dietary supplements, botanicals and complementary medicines, and several pharmacopoeias contain monographs for ginkgo leaf, leaf extract and finished products. Being a high-value botanical commodity, ginkgo extracts may be the subject of economically motivated adulteration. We analysed eight ginkgo leaf retail products purchased in Australia and Denmark and found compelling evidence of adulteration with flavonol aglycones in three of these. The same three products also contained genistein, an isoflavone that does not occur in ginkgo leaf. Although the United States Pharmacopeia - National Formulary (USP-NF) and the British and European Pharmacopoeias stipulate a required range for flavonol glycosides in ginkgo extract, the prescribed assays quantify flavonol aglycones. This means that these pharmacopoeial methods are not capable of detecting adulteration of ginkgo extract with free flavonol aglycones. We propose a simple modification of the USP-NF method that addresses this problem: by assaying for flavonol aglycones pre and post hydrolysis the content of flavonol glycosides can be accurately estimated via a simple calculation. We also recommend a maximum limit be set for free flavonol aglycones in ginkgo extract. Copyright © 2014 Elsevier GmbH. All rights reserved.

  19. [Determination of acetochlor and oxyfluorfen by capillary gas chromatography].

    PubMed

    Xiang, Wen-Sheng; Wang, Xiang-Jing; Wang, Jing; Wang, Qing

    2002-09-01

    A method is described for the determination of acetochlor and oxyfluorfen by capillary gas chromatography with FID and an SE-30 capillary column (60 m x 0.53 mm i. d., 1.5 microm), using dibutyl phthalate as the internal standard. The standard deviations for acetochlor and oxyfluorfen concentration(mass fraction) were 0.44% and 0.47% respectively. The relative standard deviations for acetochlor and oxyfluorfen were 0.79% and 0.88% and the average recoveries for acetochlor and oxyfluorfen were 99.3% and 101.1% respectively. The method is simple, rapid and accurate.

  20. Cross Check of NOvA Oscillation Probabilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parke, Stephen J.; Messier, Mark D.

    2018-01-12

    In this note we perform a cross check of the programs used by NOvA to calculate the 3-flavor oscillation probabilities with a independent program using a different method. The comparison is performed at 6 significant figures and the agreement,more » $$|\\Delta P|/P$$ is better than $$10^{-5}$$, as good as can be expected with 6 significant figures. In addition, a simple and accurate alternative method to calculate the oscillation probabilities is outlined and compared in the L/E range and matter density relevant for the NOvA experiment.« less

  1. Foucault's method for measuring the speed of light with modern apparatus

    NASA Astrophysics Data System (ADS)

    Vörös, Zoltán; Weihs, Gregor

    2015-05-01

    In this paper, we introduce two simple and inexpensive, yet quite accurate versions of the well-known Foucault method for measuring the speed of light. In a compact footprint of just 20 cm by 270 cm with readily available laboratory items, a rotating mirror taken from a laser printer, and a webcam, we obtained c=296\\720+/- 3000 km s-1, and c=302\\295+/- 3000 km s-1, respectively, both within less than a per cent of the defined value. The experiment also prepares students for extracting data through image processing.

  2. Measuring Seebeck Coefficient

    NASA Technical Reports Server (NTRS)

    Snyder, G. Jeffrey (Inventor)

    2015-01-01

    A high temperature Seebeck coefficient measurement apparatus and method with various features to minimize typical sources of errors is described. Common sources of temperature and voltage measurement errors which may impact accurate measurement are identified and reduced. Applying the identified principles, a high temperature Seebeck measurement apparatus and method employing a uniaxial, four-point geometry is described to operate from room temperature up to 1300K. These techniques for non-destructive Seebeck coefficient measurements are simple to operate, and are suitable for bulk samples with a broad range of physical types and shapes.

  3. Modulational estimate for the maximal Lyapunov exponent in Fermi-Pasta-Ulam chains

    NASA Astrophysics Data System (ADS)

    Dauxois, Thierry; Ruffo, Stefano; Torcini, Alessandro

    1997-12-01

    In the framework of the Fermi-Pasta-Ulam (FPU) model, we show a simple method to give an accurate analytical estimation of the maximal Lyapunov exponent at high energy density. The method is based on the computation of the mean value of the modulational instability growth rates associated to unstable modes. Moreover, we show that the strong stochasticity threshold found in the β-FPU system is closely related to a transition in tangent space, the Lyapunov eigenvector being more localized in space at high energy.

  4. Streamline similarity method for flow distributions and shock losses at the impeller inlet of the centrifugal pump

    NASA Astrophysics Data System (ADS)

    Zhang, Zh.

    2018-02-01

    An analytical method is presented, which enables the non-uniform velocity and pressure distributions at the impeller inlet of a pump to be accurately computed. The analyses are based on the potential flow theory and the geometrical similarity of the streamline distribution along the leading edge of the impeller blades. The method is thus called streamline similarity method (SSM). The obtained geometrical form of the flow distribution is then simply described by the geometrical variable G( s) and the first structural constant G I . As clearly demonstrated and also validated by experiments, both the flow velocity and the pressure distributions at the impeller inlet are usually highly non-uniform. This knowledge is indispensible for impeller blade designs to fulfill the shockless inlet flow condition. By introducing the second structural constant G II , the paper also presents the simple and accurate computation of the shock loss, which occurs at the impeller inlet. The introduction of two structural constants contributes immensely to the enhancement of the computational accuracies. As further indicated, all computations presented in this paper can also be well applied to the non-uniform exit flow out of an impeller of the Francis turbine for accurately computing the related mean values.

  5. Detection of ESBL among ampc producing enterobacteriaceae using inhibitor-based method

    PubMed Central

    Bakthavatchalu, Sasirekha; Shakthivel, Uma; Mishra, Tannu

    2013-01-01

    Introduction The occurrence of multiple β-lactamases among bacteria only limits the therapeutic options but also poses a challenge. A study using boronic acid (BA), an AmpC enzyme inhibitor, was designed to detect the combined expression of AmpC β-lactamases and extended-spectrum β-lactamases (ESBLs) in bacterial isolates further different phenotypic methods are compared to detect ESBL and AmpC. Methods A total of 259 clinical isolates of Enterobacteriaceae were isolated and screened for ESBL production by (i) CLSI double-disk diffusion method (ii) cefepime- clavulanic acid method (iii) boronic disk potentiation method. AmpC production was detected using cefoxitin alone and in combination with boronic acid and confirmation was done by three dimensional disk methods. Isolates were also subjected to detailed antibiotic susceptibility test. Results Among 259 isolates, 20.46% were coproducers of ESBL and AmpC, 26.45% were ESBL and 5.40% were AmpC. All of the 53 AmpC and ESBL coproducers were accurately detected by boronic acid disk potentiation method. Conclusion The BA disk test using Clinical and Laboratory Standards Institute methodology is simple and very efficient method that accurately detects the isolates that harbor both AmpCs and ESBLs. PMID:23504148

  6. Determination of exposure multiples of human metabolites for MIST assessment in preclinical safety species without using reference standards or radiolabeled compounds.

    PubMed

    Ma, Shuguang; Li, Zhiling; Lee, Keun-Joong; Chowdhury, Swapan K

    2010-12-20

    A simple, reliable, and accurate method was developed for quantitative assessment of metabolite coverage in preclinical safety species by mixing equal volumes of human plasma with blank plasma of animal species and vice versa followed by an analysis using high-resolution full-scan accurate mass spectrometry. This approach provided comparable results (within (±15%) to those obtained from regulated bioanalysis and did not require synthetic standards or radiolabeled compounds. In addition, both qualitative and quantitative data were obtained from a single LC-MS analysis on all metabolites and, therefore, the coverage of any metabolite of interest can be obtained.

  7. Validation and Application of a Simple UHPLC-MS-MS Method for the Enantiospecific Determination of Warfarin in Human Urine.

    PubMed

    Alshogran, Osama Y; Ocque, Andrew J; Leblond, François A; Pichette, Vincent; Nolin, Thomas D

    2016-04-01

    A simple and rapid liquid chromatographic-tandem mass spectrometric method has been developed and validated for the enantiospecific determination of R- and S-warfarin in human urine. Warfarin enantiomers were extracted from urine using methyl tert-butyl ether. Chromatographic separation of warfarin enantiomers and the internal standard d5-warfarin was achieved using a Astec Chirobiotic V column with gradient mobile phase at a flow rate of 400 µL/min over 10 min. Detection was performed on a TSQ Quantum Ultra triple quadrupole mass spectrometer equipped with a heated electrospray ionization source. Analytes were detected in negative ionization mode using selected reaction monitoring. Calibration curves were linear with a correlation coefficient of ≥0.996 for both enantiomers over a concentration range of 5-500 ng/mL. The intra- and interday accuracy and precision for both analytes were within ±9.0%. Excellent extraction efficiency and negligible matrix effects were observed. The applicability of the method was demonstrated by successful measurement of warfarin enantiomers in urine of patients with kidney disease. The method is simple, accurate and reproducible and is currently being used to support warfarin pharmacokinetic studies. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Comments on the variational modified-hypernetted-chain theory for simple fluids

    NASA Astrophysics Data System (ADS)

    Rosenfeld, Yaakov

    1986-02-01

    The variational modified-hypernetted-chain (VMHNC) theory, based on the approximation of universality of the bridge functions, is reformulated. The new formulation includes recent calculations by Lado and by Lado, Foiles, and Ashcroft, as two stages in a systematic approach which is analyzed. A variational iterative procedure for solving the exact (diagrammatic) equations for the fluid structure which is formally identical to the VMHNC is described, featuring the theory of simple classical fluids as a one-iteration theory. An accurate method for calculating the pair structure for a given potential and for inverting structure factor data in order to obtain the potential and the thermodynamic functions, follows from our analysis.

  9. Simple extrapolation method to predict the electronic structure of conjugated polymers from calculations on oligomers

    DOE PAGES

    Larsen, Ross E.

    2016-04-12

    In this study, we introduce two simple tight-binding models, which we call fragment frontier orbital extrapolations (FFOE), to extrapolate important electronic properties to the polymer limit using electronic structure calculations on only a few small oligomers. In particular, we demonstrate by comparison to explicit density functional theory calculations that for long oligomers the energies of the highest occupied molecular orbital (HOMO), the lowest unoccupied molecular orbital (LUMO), and of the first electronic excited state are accurately described as a function of number of repeat units by a simple effective Hamiltonian parameterized from electronic structure calculations on monomers, dimers and, optionally,more » tetramers. For the alternating copolymer materials that currently comprise some of the most efficient polymer organic photovoltaic devices one can use these simple but rigorous models to extrapolate computed properties to the polymer limit based on calculations on a small number of low-molecular-weight oligomers.« less

  10. Magnetic Field Analysis of Lorentz Motors Using a Novel Segmented Magnetic Equivalent Circuit Method

    PubMed Central

    Qian, Junbing; Chen, Xuedong; Chen, Han; Zeng, Lizhan; Li, Xiaoqing

    2013-01-01

    A simple and accurate method based on the magnetic equivalent circuit (MEC) model is proposed in this paper to predict magnetic flux density (MFD) distribution of the air-gap in a Lorentz motor (LM). In conventional MEC methods, the permanent magnet (PM) is treated as one common source and all branches of MEC are coupled together to become a MEC network. In our proposed method, every PM flux source is divided into three sub-sections (the outer, the middle and the inner). Thus, the MEC of LM is divided correspondingly into three independent sub-loops. As the size of the middle sub-MEC is small enough, it can be treated as an ideal MEC and solved accurately. Combining with decoupled analysis of outer and inner MECs, MFD distribution in the air-gap can be approximated by a quadratic curve, and the complex calculation of reluctances in MECs can be avoided. The segmented magnetic equivalent circuit (SMEC) method is used to analyze a LM, and its effectiveness is demonstrated by comparison with FEA, conventional MEC and experimental results. PMID:23358368

  11. An Edge-Based Method for the Incompressible Navier-Stokes Equations on Polygonal Meshes

    NASA Astrophysics Data System (ADS)

    Wright, Jeffrey A.; Smith, Richard W.

    2001-05-01

    A pressure-based method is presented for discretizing the unsteady incompressible Navier-Stokes equations using hybrid unstructured meshes. The edge-based data structure and assembly procedure adopted lead naturally to a strictly conservative discretization, which is valid for meshes composed of n-sided polygons. Particular attention is given to the construction of a pressure-velocity coupling procedure which is supported by edge data, resulting in a relatively simple numerical method that is consistent with the boundary and initial conditions required by the incompressible Navier-Stokes equations. Edge formulas are presented for assembling the momentum equations, which are based on an upwind-biased linear reconstruction of the velocity field. Similar formulas are presented for assembling the pressure equation. The method is demonstrated to be second-order accurate in space and time for two Navier-Stokes problems admitting an exact solution. Results for several other well-known problems are also presented, including lid-driven cavity flow, impulsively started cylinder flow, and unsteady vortex shedding from a circular cylinder. Although the method is by construction minimalist, it is shown to be accurate and robust for the problems considered.

  12. Stoichiometric determination of moisture in edible oils by Mid-FTIR spectroscopy.

    PubMed

    van de Voort, F R; Tavassoli-Kafrani, M H; Curtis, J M

    2016-04-28

    A simple and accurate method for the determination of moisture in edible oils by differential FTIR spectroscopy has been devised based on the stoichiometric reaction of the moisture in oil with toluenesulfonyl isocyanate (TSI) to produce CO2. Calibration standards were devised by gravimetrically spiking dry dioxane with water, followed by the addition of neat TSI and examination of the differential spectra relative to the dry dioxane. In the method, CO2 peak area changes are measured at 2335 cm(-1) and were shown to be related to the amount of moisture added, with any CO2 inherent to residual moisture in the dry dioxane subtracted ratioed out. CO2 volatility issues were determined to be minimal, with the overall SD of dioxane calibrations being ∼18 ppm over a range of 0-1000 ppm. Gravimetrically blended dry and water-saturated oils analysed in a similar manner produced linear CO2 responses with SD's of <15 ppm on average. One set of dry-wet blends was analysed in duplicate by FTIR and by two independent laboratories using coulometric Karl Fischer (KF) procedures. All 3 methods produced highly linear moisture relationships with SD's of 7, 16 and 28 ppm, respectively over a range of 200-1500 ppm. Although the absolute moisture values obtained by each method did not exactly coincide, each tracked the expected moisture changes proportionately. The FTIRTSI-H2O method provides a simple and accurate instrumental means of determining moisture in oils rivaling the accuracy and specificity of standard KF procedures and has the potential to be automated. It could also be applied to other hydrophobic matrices and possibly evolve into a more generalized method, if combined with polar aprotic solvent extraction. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. A general method for bead-enhanced quantitation by flow cytometry

    PubMed Central

    Montes, Martin; Jaensson, Elin A.; Orozco, Aaron F.; Lewis, Dorothy E.; Corry, David B.

    2009-01-01

    Flow cytometry provides accurate relative cellular quantitation (percent abundance) of cells from diverse samples, but technical limitations of most flow cytometers preclude accurate absolute quantitation. Several quantitation standards are now commercially available which, when added to samples, permit absolute quantitation of CD4+ T cells. However, these reagents are limited by their cost, technical complexity, requirement for additional software and/or limited applicability. Moreover, few studies have validated the use of such reagents in complex biological samples, especially for quantitation of non-T cells. Here we show that addition to samples of known quantities of polystyrene fluorescence standardization beads permits accurate quantitation of CD4+ T cells from complex cell samples. This procedure, here termed single bead-enhanced cytofluorimetry (SBEC), was equally capable of enumerating eosinophils as well as subcellular fragments of apoptotic cells, moieties with very different optical and fluorescent characteristics. Relative to other proprietary products, SBEC is simple, inexpensive and requires no special software, suggesting that the method is suitable for the routine quantitation of most cells and other particles by flow cytometry. PMID:17067632

  14. Towards discrete wavelet transform-based human activity recognition

    NASA Astrophysics Data System (ADS)

    Khare, Manish; Jeon, Moongu

    2017-06-01

    Providing accurate recognition of human activities is a challenging problem for visual surveillance applications. In this paper, we present a simple and efficient algorithm for human activity recognition based on a wavelet transform. We adopt discrete wavelet transform (DWT) coefficients as a feature of human objects to obtain advantages of its multiresolution approach. The proposed method is tested on multiple levels of DWT. Experiments are carried out on different standard action datasets including KTH and i3D Post. The proposed method is compared with other state-of-the-art methods in terms of different quantitative performance measures. The proposed method is found to have better recognition accuracy in comparison to the state-of-the-art methods.

  15. Simple transfer calibration method for a Cimel Sun-Moon photometer: calculating lunar calibration coefficients from Sun calibration constants.

    PubMed

    Li, Zhengqiang; Li, Kaitao; Li, Donghui; Yang, Jiuchun; Xu, Hua; Goloub, Philippe; Victori, Stephane

    2016-09-20

    The Cimel new technologies allow both daytime and nighttime aerosol optical depth (AOD) measurements. Although the daytime AOD calibration protocols are well established, accurate and simple nighttime calibration is still a challenging task. Standard lunar-Langley and intercomparison calibration methods both require specific conditions in terms of atmospheric stability and site condition. Additionally, the lunar irradiance model also has some known limits on its uncertainty. This paper presents a simple calibration method that transfers the direct-Sun calibration constant, V0,Sun, to the lunar irradiance calibration coefficient, CMoon. Our approach is a pure calculation method, independent of site limits, e.g., Moon phase. The method is also not affected by the lunar irradiance model limitations, which is the largest error source of traditional calibration methods. Besides, this new transfer calibration approach is easy to use in the field since CMoon can be obtained directly once V0,Sun is known. Error analysis suggests that the average uncertainty of CMoon over the 440-1640 nm bands obtained with the transfer method is 2.4%-2.8%, depending on the V0,Sun approach (Langley or intercomparison), which is comparable with that of lunar-Langley approach, theoretically. In this paper, the Sun-Moon transfer and the Langley methods are compared based on site measurements in Beijing, and the day-night measurement continuity and performance are analyzed.

  16. A Simple Method for Deriving the Confidence Regions for the Penalized Cox’s Model via the Minimand Perturbation†

    PubMed Central

    Lin, Chen-Yen; Halabi, Susan

    2017-01-01

    We propose a minimand perturbation method to derive the confidence regions for the regularized estimators for the Cox’s proportional hazards model. Although the regularized estimation procedure produces a more stable point estimate, it remains challenging to provide an interval estimator or an analytic variance estimator for the associated point estimate. Based on the sandwich formula, the current variance estimator provides a simple approximation, but its finite sample performance is not entirely satisfactory. Besides, the sandwich formula can only provide variance estimates for the non-zero coefficients. In this article, we present a generic description for the perturbation method and then introduce a computation algorithm using the adaptive least absolute shrinkage and selection operator (LASSO) penalty. Through simulation studies, we demonstrate that our method can better approximate the limiting distribution of the adaptive LASSO estimator and produces more accurate inference compared with the sandwich formula. The simulation results also indicate the possibility of extending the applications to the adaptive elastic-net penalty. We further demonstrate our method using data from a phase III clinical trial in prostate cancer. PMID:29326496

  17. A Simple Method for Deriving the Confidence Regions for the Penalized Cox's Model via the Minimand Perturbation.

    PubMed

    Lin, Chen-Yen; Halabi, Susan

    2017-01-01

    We propose a minimand perturbation method to derive the confidence regions for the regularized estimators for the Cox's proportional hazards model. Although the regularized estimation procedure produces a more stable point estimate, it remains challenging to provide an interval estimator or an analytic variance estimator for the associated point estimate. Based on the sandwich formula, the current variance estimator provides a simple approximation, but its finite sample performance is not entirely satisfactory. Besides, the sandwich formula can only provide variance estimates for the non-zero coefficients. In this article, we present a generic description for the perturbation method and then introduce a computation algorithm using the adaptive least absolute shrinkage and selection operator (LASSO) penalty. Through simulation studies, we demonstrate that our method can better approximate the limiting distribution of the adaptive LASSO estimator and produces more accurate inference compared with the sandwich formula. The simulation results also indicate the possibility of extending the applications to the adaptive elastic-net penalty. We further demonstrate our method using data from a phase III clinical trial in prostate cancer.

  18. A simple, fast and accurate in-situ method to measure the rate of transport of redox species through membranes for lithium batteries

    NASA Astrophysics Data System (ADS)

    Meddings, Nina; Owen, John R.; Garcia-Araez, Nuria

    2017-10-01

    Lithium ion conducting membranes are important to protect the lithium metal electrode and act as a barrier to crossover species such as polysulphides in Li-S systems, redox mediators in Li-O2 cells or dissolved cathode species or electrolyte oxidation products in high voltage Li-ion batteries. We present an in-situ method for measuring permeability of membranes to crossover redox species. The method employs a 'Swagelok' cell design equipped with a glassy carbon working electrode, in which redox species are placed initially in the counter electrode compartment only. Permeability through the membrane, which separates working and counter electrodes, is determined using a square wave voltammetry technique that allows the concentration of crossover redox species to be evaluated over time with very high precision. We test the method using a model and well-behaved electrochemical system to demonstrate its sensitivity, reproducibility and reliability relative to alternative approaches. This new method offers advantages in terms of small electrolyte volume, and simple, fast, quantitative and in-situ measurement.

  19. Development of the local magnification method for quantitative evaluation of endoscope geometric distortion

    NASA Astrophysics Data System (ADS)

    Wang, Quanzeng; Cheng, Wei-Chung; Suresh, Nitin; Hua, Hong

    2016-05-01

    With improved diagnostic capabilities and complex optical designs, endoscopic technologies are advancing. As one of the several important optical performance characteristics, geometric distortion can negatively affect size estimation and feature identification related diagnosis. Therefore, a quantitative and simple distortion evaluation method is imperative for both the endoscopic industry and the medical device regulatory agent. However, no such method is available yet. While the image correction techniques are rather mature, they heavily depend on computational power to process multidimensional image data based on complex mathematical model, i.e., difficult to understand. Some commonly used distortion evaluation methods, such as the picture height distortion (DPH) or radial distortion (DRAD), are either too simple to accurately describe the distortion or subject to the error of deriving a reference image. We developed the basic local magnification (ML) method to evaluate endoscope distortion. Based on the method, we also developed ways to calculate DPH and DRAD. The method overcomes the aforementioned limitations, has clear physical meaning in the whole field of view, and can facilitate lesion size estimation during diagnosis. Most importantly, the method can facilitate endoscopic technology to market and potentially be adopted in an international endoscope standard.

  20. Finite difference elastic wave modeling with an irregular free surface using ADER scheme

    NASA Astrophysics Data System (ADS)

    Almuhaidib, Abdulaziz M.; Nafi Toksöz, M.

    2015-06-01

    In numerical modeling of seismic wave propagation in the earth, we encounter two important issues: the free surface and the topography of the surface (i.e. irregularities). In this study, we develop a 2D finite difference solver for the elastic wave equation that combines a 4th- order ADER scheme (Arbitrary high-order accuracy using DERivatives), which is widely used in aeroacoustics, with the characteristic variable method at the free surface boundary. The idea is to treat the free surface boundary explicitly by using ghost values of the solution for points beyond the free surface to impose the physical boundary condition. The method is based on the velocity-stress formulation. The ultimate goal is to develop a numerical solver for the elastic wave equation that is stable, accurate and computationally efficient. The solver treats smooth arbitrary-shaped boundaries as simple plane boundaries. The computational cost added by treating the topography is negligible compared to flat free surface because only a small number of grid points near the boundary need to be computed. In the presence of topography, using 10 grid points per shortest shear-wavelength, the solver yields accurate results. Benchmark numerical tests using several complex models that are solved by our method and other independent accurate methods show an excellent agreement, confirming the validity of the method for modeling elastic waves with an irregular free surface.

  1. MULTI-K: accurate classification of microarray subtypes using ensemble k-means clustering

    PubMed Central

    Kim, Eun-Youn; Kim, Seon-Young; Ashlock, Daniel; Nam, Dougu

    2009-01-01

    Background Uncovering subtypes of disease from microarray samples has important clinical implications such as survival time and sensitivity of individual patients to specific therapies. Unsupervised clustering methods have been used to classify this type of data. However, most existing methods focus on clusters with compact shapes and do not reflect the geometric complexity of the high dimensional microarray clusters, which limits their performance. Results We present a cluster-number-based ensemble clustering algorithm, called MULTI-K, for microarray sample classification, which demonstrates remarkable accuracy. The method amalgamates multiple k-means runs by varying the number of clusters and identifies clusters that manifest the most robust co-memberships of elements. In addition to the original algorithm, we newly devised the entropy-plot to control the separation of singletons or small clusters. MULTI-K, unlike the simple k-means or other widely used methods, was able to capture clusters with complex and high-dimensional structures accurately. MULTI-K outperformed other methods including a recently developed ensemble clustering algorithm in tests with five simulated and eight real gene-expression data sets. Conclusion The geometric complexity of clusters should be taken into account for accurate classification of microarray data, and ensemble clustering applied to the number of clusters tackles the problem very well. The C++ code and the data sets tested are available from the authors. PMID:19698124

  2. Hi-Plex for Simple, Accurate, and Cost-Effective Amplicon-based Targeted DNA Sequencing.

    PubMed

    Pope, Bernard J; Hammet, Fleur; Nguyen-Dumont, Tu; Park, Daniel J

    2018-01-01

    Hi-Plex is a suite of methods to enable simple, accurate, and cost-effective highly multiplex PCR-based targeted sequencing (Nguyen-Dumont et al., Biotechniques 58:33-36, 2015). At its core is the principle of using gene-specific primers (GSPs) to "seed" (or target) the reaction and universal primers to "drive" the majority of the reaction. In this manner, effects on amplification efficiencies across the target amplicons can, to a large extent, be restricted to early seeding cycles. Product sizes are defined within a relatively narrow range to enable high-specificity size selection, replication uniformity across target sites (including in the context of fragmented input DNA such as that derived from fixed tumor specimens (Nguyen-Dumont et al., Biotechniques 55:69-74, 2013; Nguyen-Dumont et al., Anal Biochem 470:48-51, 2015), and application of high-specificity genetic variant calling algorithms (Pope et al., Source Code Biol Med 9:3, 2014; Park et al., BMC Bioinformatics 17:165, 2016). Hi-Plex offers a streamlined workflow that is suitable for testing large numbers of specimens without the need for automation.

  3. Quantification of urinary zwitterionic organic acids using weak-anion exchange chromatography with tandem MS detection.

    PubMed

    Bishop, Michael Jason; Crow, Brian S; Kovalcik, Kasey D; George, Joe; Bralley, James A

    2007-04-01

    A rapid and accurate quantitative method was developed and validated for the analysis of four urinary organic acids with nitrogen containing functional groups, formiminoglutamic acid (FIGLU), pyroglutamic acid (PYRGLU), 5-hydroxyindoleacetic acid (5-HIAA), and 2-methylhippuric acid (2-METHIP) by liquid chromatography tandem mass spectrometry (LC/MS/MS). The chromatography was developed using a weak anion-exchange amino column that provided mixed-mode retention of the analytes. The elution gradient relied on changes in mobile phase pH over a concave gradient, without the use of counter-ions or concentrated salt buffers. A simple sample preparation was used, only requiring the dilution of urine prior to instrumental analysis. The method was validated based on linearity (r2>or=0.995), accuracy (85-115%), precision (C.V.<12%), sample preparation stability (

  4. Geographic information system (GIS)-based image analysis for assessing growth of Physarum polycephalum on a solid medium.

    PubMed

    Tran, Hanh T M; Stephenson, Steven L; Tullis, Jason A

    2015-01-01

    The conventional method used to assess growth of the plasmodium of the slime mold Physarum polycephalum in solid culture is to measure the extent of plasmodial expansion from the point of inoculation by using a ruler. However, plasmodial growth is usually rather irregular, so the values obtained are not especially accurate. Similar challenges exist in quantification of the growth of a fungal mycelium. In this paper, we describe a method that uses geographic information system software to obtain highly accurate estimates of plasmodial growth over time. This approach calculates plasmodial area from images obtained at particular intervals following inoculation. In addition, the correlation between plasmodial area and its dry cell weight value was determined. The correlation could be used for biomass estimation without the need of having to terminate the cultures in question. The method described herein is simple but effective and could also be used for growth measurements of other microorganisms such as fungi on solid media.

  5. A study on suppressing transmittance fluctuations for air-gapped Glan-type polarizing prisms

    NASA Astrophysics Data System (ADS)

    Zhang, Chuanfa; Li, Dailin; Zhu, Huafeng; Li, Chuanzhi; Jiao, Zhiyong; Wang, Ning; Xu, Zhaopeng; Wang, Xiumin; Song, Lianke

    2018-05-01

    Light intensity transmittance is a key parameter for the design of polarizing prisms, while sometimes its experimental curves based on spatial incident angle presents periodical fluctuations. Here, we propose a novel method for completely suppressing these fluctuations via setting a glued error angle in the air gap of Glan-Taylor prisms. The proposal consists of: an accurate formula of the intensity transmittance for Glan-Taylor prisms, a numerical simulation and a contrast experiment of Glan-Taylor prisms for analyzing the causes of the fluctuations, and a simple method for accurately measuring the glued error angle. The result indicates that when the setting glued error angle is larger than the critical angle for a certain polarizing prism, the fluctuations can be completely suppressed, and a smooth intensity transmittance curve can be obtained. Besides, the critical angle in the air gap for suppressing the fluctuations is decreased with the increase of beam spot size. This method has the advantage of having less demand for the prism position in optical systems.

  6. A 4-Dimensional Representation of Antennal Lobe Output Based on an Ensemble of Characterized Projection Neurons

    PubMed Central

    Staudacher, Erich M.; Huetteroth, Wolf; Schachtner, Joachim; Daly, Kevin C.

    2009-01-01

    A central problem facing studies of neural encoding in sensory systems is how to accurately quantify the extent of spatial and temporal responses. In this study, we take advantage of the relatively simple and stereotypic neural architecture found in invertebrates. We combine standard electrophysiological techniques, recently developed population analysis techniques, and novel anatomical methods to form an innovative 4-dimensional view of odor output representations in the antennal lobe of the moth Manduca sexta. This novel approach allows quantification of olfactory responses of characterized neurons with spike time resolution. Additionally, arbitrary integration windows can be used for comparisons with other methods such as imaging. By assigning statistical significance to changes in neuronal firing, this method can visualize activity across the entire antennal lobe. The resulting 4-dimensional representation of antennal lobe output complements imaging and multi-unit experiments yet provides a more comprehensive and accurate view of glomerular activation patterns in spike time resolution. PMID:19464513

  7. IDLN-MSP: Idiolocal normalization of real-time methylation-specific PCR for genetic imbalanced DNA specimens.

    PubMed

    Santourlidis, Simeon; Ghanjati, Foued; Beermann, Agnes; Hermanns, Thomas; Poyet, Cédric

    2016-02-01

    Sensitive, accurate, and reliable measurements of tumor cell-specific DNA methylation changes are of fundamental importance in cancer diagnosis, prognosis, and monitoring. Real-time methylation-specific PCR (MSP) using intercalating dyes is an established method of choice for this purpose. Here we present a simple but crucial adaptation of this widely applied method that overcomes a major obstacle: genetic abnormalities in the DNA samples, such as aneuploidy or copy number variations, that could result in inaccurate results due to improper normalization if the copy numbers of the target and reference sequences are not the same. In our idiolocal normalization (IDLN) method, the locus for the normalizing, methylation-independent reference amplification is chosen close to the locus of the methylation-dependent target amplification. This ensures that the copy numbers of both the target and reference sequences will be identical in most cases if they are close enough to each other, resulting in accurate normalization and reliable comparative measurements of DNA methylation in clinical samples when using real-time MSP.

  8. Accurate van der Waals coefficients from density functional theory

    PubMed Central

    Tao, Jianmin; Perdew, John P.; Ruzsinszky, Adrienn

    2012-01-01

    The van der Waals interaction is a weak, long-range correlation, arising from quantum electronic charge fluctuations. This interaction affects many properties of materials. A simple and yet accurate estimate of this effect will facilitate computer simulation of complex molecular materials and drug design. Here we develop a fast approach for accurate evaluation of dynamic multipole polarizabilities and van der Waals (vdW) coefficients of all orders from the electron density and static multipole polarizabilities of each atom or other spherical object, without empirical fitting. Our dynamic polarizabilities (dipole, quadrupole, octupole, etc.) are exact in the zero- and high-frequency limits, and exact at all frequencies for a metallic sphere of uniform density. Our theory predicts dynamic multipole polarizabilities in excellent agreement with more expensive many-body methods, and yields therefrom vdW coefficients C6, C8, C10 for atom pairs with a mean absolute relative error of only 3%. PMID:22205765

  9. A practical method of estimating stature of bedridden female nursing home patients.

    PubMed

    Muncie, H L; Sobal, J; Hoopes, J M; Tenney, J H; Warren, J W

    1987-04-01

    Accurate measurement of stature is important for the determination of several nutritional indices as well as body surface area (BSA) for the normalization of creatinine clearances. Direct standing measurement of stature of bedridden elderly nursing home patients is impossible, and stature as recorded in the chart may not be valid. An accurate stature obtained by summing five segmental measurements was compared to the stature recorded in the patient's chart and calculated estimates of stature from measurement of a long bone (humerus, tibia, knee height). Estimation of stature from measurement of knee height was highly correlated (r = 0.93) to the segmental measurement of stature while estimates from other long-bone measurements were less highly correlated (r = 0.71 to 0.81). Recorded chart stature was poorly correlated (r = 0.37). Measurement of knee height provides a simple, quick, and accurate means of estimating stature for bedridden females in nursing homes.

  10. Calculation of three-dimensional compressible laminar and turbulent boundary layers. An implicit finite-difference procedure for solving the three-dimensional compressible laminar, transitional, and turbulent boundary-layer equations

    NASA Technical Reports Server (NTRS)

    Harris, J. E.

    1975-01-01

    An implicit finite-difference procedure is presented for solving the compressible three-dimensional boundary-layer equations. The method is second-order accurate, unconditionally stable (conditional stability for reverse cross flow), and efficient from the viewpoint of computer storage and processing time. The Reynolds stress terms are modeled by (1) a single-layer mixing length model and (2) a two-layer eddy viscosity model. These models, although simple in concept, accurately predicted the equilibrium turbulent flow for the conditions considered. Numerical results are compared with experimental wall and profile data for a cone at an angle of attack larger than the cone semiapex angle. These comparisons clearly indicate that the numerical procedure and turbulence models accurately predict the experimental data with as few as 21 nodal points in the plane normal to the wall boundary.

  11. Fixed-rate layered multicast congestion control

    NASA Astrophysics Data System (ADS)

    Bing, Zhang; Bing, Yuan; Zengji, Liu

    2006-10-01

    A new fixed-rate layered multicast congestion control algorithm called FLMCC is proposed. The sender of a multicast session transmits data packets at a fixed rate on each layer, while receivers each obtain different throughput by cumulatively subscribing to deferent number of layers based on their expected rates. In order to provide TCP-friendliness and estimate the expected rate accurately, a window-based mechanism implemented at receivers is presented. To achieve this, each receiver maintains a congestion window, adjusts it based on the GAIMD algorithm, and from the congestion window an expected rate is calculated. To measure RTT, a new method is presented which combines an accurate measurement with a rough estimation. A feedback suppression based on a random timer mechanism is given to avoid feedback implosion in the accurate measurement. The protocol is simple in its implementation. Simulations indicate that FLMCC shows good TCP-friendliness, responsiveness as well as intra-protocol fairness, and provides high link utilization.

  12. A novel medical information management and decision model for uncertain demand optimization.

    PubMed

    Bi, Ya

    2015-01-01

    Accurately planning the procurement volume is an effective measure for controlling the medicine inventory cost. Due to uncertain demand it is difficult to make accurate decision on procurement volume. As to the biomedicine sensitive to time and season demand, the uncertain demand fitted by the fuzzy mathematics method is obviously better than general random distribution functions. To establish a novel medical information management and decision model for uncertain demand optimization. A novel optimal management and decision model under uncertain demand has been presented based on fuzzy mathematics and a new comprehensive improved particle swarm algorithm. The optimal management and decision model can effectively reduce the medicine inventory cost. The proposed improved particle swarm optimization is a simple and effective algorithm to improve the Fuzzy interference and hence effectively reduce the calculation complexity of the optimal management and decision model. Therefore the new model can be used for accurate decision on procurement volume under uncertain demand.

  13. Remote sensing techniques for prediction of watershed runoff

    NASA Technical Reports Server (NTRS)

    Blanchard, B. J.

    1975-01-01

    Hydrologic parameters of watersheds for use in mathematical models and as design criteria for flood detention structures are sometimes difficult to quantify using conventional measuring systems. The advent of remote sensing devices developed in the past decade offers the possibility that watershed characteristics such as vegetative cover, soils, soil moisture, etc., may be quantified rapidly and economically. Experiments with visible and near infrared data from the LANDSAT-1 multispectral scanner indicate a simple technique for calibration of runoff equation coefficients is feasible. The technique was tested on 10 watersheds in the Chickasha area and test results show more accurate runoff coefficients were obtained than with conventional methods. The technique worked equally as well using a dry fall scene. The runoff equation coefficients were then predicted for 22 subwatersheds with flood detention structures. Predicted values were again more accurate than coefficients produced by conventional methods.

  14. Using an analytical geometry method to improve tiltmeter data presentation

    USGS Publications Warehouse

    Su, W.-J.

    2000-01-01

    The tiltmeter is a useful tool for geologic and geotechnical applications. To obtain full benefit from the tiltmeter, easy and accurate data presentations should be used. Unfortunately, the most commonly used method for tilt data reduction now may yield inaccurate and low-resolution results. This article describes a simple, accurate, and high-resolution approach developed at the Illinois State Geological Survey for data reduction and presentation. The orientation of tiltplates is determined first by using a trigonometric relationship, followed by a matrix transformation, to obtain the true amount of rotation change of the tiltplate at any given time. The mathematical derivations used for the determination and transformation are then coded into an integrated PC application by adapting the capabilities of commercial spreadsheet, database, and graphics software. Examples of data presentation from tiltmeter applications in studies of landfill covers, characterizations of mine subsidence, and investigations of slope stability are also discussed.

  15. Methods for Real-Time Prediction of the Mode of Travel Using Smartphone-Based GPS and Accelerometer Data

    PubMed Central

    Martin, Bryan D.; Wolfson, Julian; Adomavicius, Gediminas; Fan, Yingling

    2017-01-01

    We propose and compare combinations of several methods for classifying transportation activity data from smartphone GPS and accelerometer sensors. We have two main objectives. First, we aim to classify our data as accurately as possible. Second, we aim to reduce the dimensionality of the data as much as possible in order to reduce the computational burden of the classification. We combine dimension reduction and classification algorithms and compare them with a metric that balances accuracy and dimensionality. In doing so, we develop a classification algorithm that accurately classifies five different modes of transportation (i.e., walking, biking, car, bus and rail) while being computationally simple enough to run on a typical smartphone. Further, we use data that required no behavioral changes from the smartphone users to collect. Our best classification model uses the random forest algorithm to achieve 96.8% accuracy. PMID:28885550

  16. Optical thermometry using fluorescence intensities multi-ratios in NaGdTiO4:Yb3+/Tm3+ phosphors

    NASA Astrophysics Data System (ADS)

    Zhou, Aihua; Song, Feng; Song, Feifei; Feng, Ming; Adnan, Khan; Ju, Dandan; Wang, Xueqing

    2018-04-01

    The NaGdTiO4:Yb3+/Tm3+ phosphor has been effectively synthesized by the traditional solid-state reaction method and its down-conversion and up-conversion luminescence properties were systematically studied. The results indicate that the electric dipole-dipole interaction is the main mechanism for the luminescence quenching. The fact that the ratios of the up-conversion intensities, i.e., I795nm/I798nm, I807nm/I798nm, and I812nm/I798nm, increase linearly with temperature (100 K-300 K) provides us a simple and accurate temperature measurement method. Multi-ratios can be more accurate than using only one ratio, allowing for self-referenced temperature determination. It's promising for NaGdTiO4: Yb3+/Tm3+ to be used for optical temperature sensors.

  17. Methods for Real-Time Prediction of the Mode of Travel Using Smartphone-Based GPS and Accelerometer Data.

    PubMed

    Martin, Bryan D; Addona, Vittorio; Wolfson, Julian; Adomavicius, Gediminas; Fan, Yingling

    2017-09-08

    We propose and compare combinations of several methods for classifying transportation activity data from smartphone GPS and accelerometer sensors. We have two main objectives. First, we aim to classify our data as accurately as possible. Second, we aim to reduce the dimensionality of the data as much as possible in order to reduce the computational burden of the classification. We combine dimension reduction and classification algorithms and compare them with a metric that balances accuracy and dimensionality. In doing so, we develop a classification algorithm that accurately classifies five different modes of transportation (i.e., walking, biking, car, bus and rail) while being computationally simple enough to run on a typical smartphone. Further, we use data that required no behavioral changes from the smartphone users to collect. Our best classification model uses the random forest algorithm to achieve 96.8% accuracy.

  18. SHORT COMMUNICATION: Recognition of supercooled dew in a quartz crystal microbalance dew-point sensor by slip phenomena

    NASA Astrophysics Data System (ADS)

    Kwon, Su-Yong; Kim, Jong-Chul; Choi, Byung-Il

    2007-10-01

    Distinguishing between a supercooled dew and frost below 0 °C in dew/frost-point measurements is an important and challenging problem that has not yet been completely solved. This study presents a new method for the recognition of a supercooled dew in a dew/frost-point sensor. A quartz crystal microbalance (QCM) sensor was used as a dew/frost-point sensor to detect a dew and a supercooled dew as well as frost. The slip phenomenon occurring at an interface between the water droplet and the surface of the quartz crystal resonator of the QCM sensor gives a simple and accurate way of distinguishing between a supercooled dew and frost below 0 °C. This method can give a highly accurate measurement of the dew or the frost point without misreading in the dew-point sensor at temperatures below 0 °C.

  19. In silico method for modelling metabolism and gene product expression at genome scale

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lerman, Joshua A.; Hyduke, Daniel R.; Latif, Haythem

    2012-07-03

    Transcription and translation use raw materials and energy generated metabolically to create the macromolecular machinery responsible for all cellular functions, including metabolism. A biochemically accurate model of molecular biology and metabolism will facilitate comprehensive and quantitative computations of an organism's molecular constitution as a function of genetic and environmental parameters. Here we formulate a model of metabolism and macromolecular expression. Prototyping it using the simple microorganism Thermotoga maritima, we show our model accurately simulates variations in cellular composition and gene expression. Moreover, through in silico comparative transcriptomics, the model allows the discovery of new regulons and improving the genome andmore » transcription unit annotations. Our method presents a framework for investigating molecular biology and cellular physiology in silico and may allow quantitative interpretation of multi-omics data sets in the context of an integrated biochemical description of an organism.« less

  20. Simple scale interpolator facilitates reading of graphs

    NASA Technical Reports Server (NTRS)

    Fetterman, D. E., Jr.

    1965-01-01

    Simple transparent overlay with interpolation scale facilitates accurate, rapid reading of graph coordinate points. This device can be used for enlarging drawings and locating points on perspective drawings.

  1. Compound Specific Extraction of Camptothecin from Nothapodytes nimmoniana and Piperine from Piper nigrum Using Accelerated Solvent Extractor

    PubMed Central

    Upadhya, Vinayak; Pai, Sandeep R.; Sharma, Ajay K.; Hegde, Harsha V.; Kholkute, Sanjiva D.; Joshi, Rajesh K.

    2014-01-01

    Effects of varying temperatures with constant pressure of solvent on extraction efficiency of two chemically different alkaloids were studied. Camptothecin (CPT) from stem of Nothapodytes nimmoniana (Grah.) Mabb. and piperine from the fruits of Piper nigrum L. were extracted using Accelerated Solvent Extractor (ASE). Three cycles of extraction for a particular sample cell at a given temperature assured complete extraction. CPT and piperine were determined and quantified by using a simple and efficient UFLC-PDA (245 and 343 nm) method. Temperature increased efficiency of extraction to yield higher amount of CPT, whereas temperature had diminutive effect on yield of piperine. Maximum yield for CPT was achieved at 80°C and for piperine at 40°C. Thus, the study determines compound specific extraction of CPT from N. nimmoniana and piperine from P. nigrum using ASE method. The present study indicates the use of this method for simple, fast, and accurate extraction of the compound of interest. PMID:24527258

  2. Cyclic voltammetry using silver as cathode material: a simple method for determining electro and chemical features and solubility values of CO2 in ionic liquids.

    PubMed

    Reche, Irene; Gallardo, Iluminada; Guirado, Gonzalo

    2015-01-28

    A report is presented on the use of cyclic voltammetry using silver as a working electrode. The combined electrocatalytic properties of silver and ionic liquids allow cyclic voltammetry to be turned into an ideal tool for the rapid and accurate access to diffusion coefficient values and solubility values of carbon dioxide in ionic liquids under standard conditions.

  3. Full-Field Stress Determination Around Circular Discontinuity in a Tensile-Loaded Plate using x-displacements Only

    NASA Astrophysics Data System (ADS)

    Baek, Tae Hyun; Chung, Tae Jin; Panganiban, Henry

    The significant effects of stress raisers demand well-defined evaluation techniques to accurately determine the stress along the geometric boundary. A simple and accurate method for the determination of stress concentration around circular geometric discontinuity in a tensile-loaded plate is illustrated. The method is based on the least-squares technique, mapping functions, and a complex power series representation (Laurent series) of the stress functions for the calculation of tangential stress around the hole. Traction-free conditions were satisfied at the geometric discontinuity using conformal mapping and analytic continuation. In this study, we use only a relatively small amount of x-component displacement data of points away from the discontinuity of concern with their respective coordinates. Having this information we can easily obtain full-field stresses at the edge of the geometric discontinuity. Excellent results were obtained when the number of terms of the power series expansions, m=1. The maximum stress concentration calculation results using the present method and FEM using ANSYS agree well by less than one per cent difference. Experimental advantage of the method underscores the use of relatively small amount of data which are conveniently determined being away from the edge. Moreover, the small amount of measured input data needed affords the approach suitable for applications such as the multi-parameter concept used to obtain stress intensity factors from measured data. The use of laser speckle interferometry and moiré interferometry are also potential future related fields since the optical system for one-directional measurement is much simple.

  4. Accurate upwind methods for the Euler equations

    NASA Technical Reports Server (NTRS)

    Huynh, Hung T.

    1993-01-01

    A new class of piecewise linear methods for the numerical solution of the one-dimensional Euler equations of gas dynamics is presented. These methods are uniformly second-order accurate, and can be considered as extensions of Godunov's scheme. With an appropriate definition of monotonicity preservation for the case of linear convection, it can be shown that they preserve monotonicity. Similar to Van Leer's MUSCL scheme, they consist of two key steps: a reconstruction step followed by an upwind step. For the reconstruction step, a monotonicity constraint that preserves uniform second-order accuracy is introduced. Computational efficiency is enhanced by devising a criterion that detects the 'smooth' part of the data where the constraint is redundant. The concept and coding of the constraint are simplified by the use of the median function. A slope steepening technique, which has no effect at smooth regions and can resolve a contact discontinuity in four cells, is described. As for the upwind step, existing and new methods are applied in a manner slightly different from those in the literature. These methods are derived by approximating the Euler equations via linearization and diagonalization. At a 'smooth' interface, Harten, Lax, and Van Leer's one intermediate state model is employed. A modification for this model that can resolve contact discontinuities is presented. Near a discontinuity, either this modified model or a more accurate one, namely, Roe's flux-difference splitting. is used. The current presentation of Roe's method, via the conceptually simple flux-vector splitting, not only establishes a connection between the two splittings, but also leads to an admissibility correction with no conditional statement, and an efficient approximation to Osher's approximate Riemann solver. These reconstruction and upwind steps result in schemes that are uniformly second-order accurate and economical at smooth regions, and yield high resolution at discontinuities.

  5. The Estimation of Tree Posterior Probabilities Using Conditional Clade Probability Distributions

    PubMed Central

    Larget, Bret

    2013-01-01

    In this article I introduce the idea of conditional independence of separated subtrees as a principle by which to estimate the posterior probability of trees using conditional clade probability distributions rather than simple sample relative frequencies. I describe an algorithm for these calculations and software which implements these ideas. I show that these alternative calculations are very similar to simple sample relative frequencies for high probability trees but are substantially more accurate for relatively low probability trees. The method allows the posterior probability of unsampled trees to be calculated when these trees contain only clades that are in other sampled trees. Furthermore, the method can be used to estimate the total probability of the set of sampled trees which provides a measure of the thoroughness of a posterior sample. [Bayesian phylogenetics; conditional clade distributions; improved accuracy; posterior probabilities of trees.] PMID:23479066

  6. The maximum specific hydrogen-producing activity of anaerobic mixed cultures: definition and determination

    PubMed Central

    Mu, Yang; Yang, Hou-Yun; Wang, Ya-Zhou; He, Chuan-Shu; Zhao, Quan-Bao; Wang, Yi; Yu, Han-Qing

    2014-01-01

    Fermentative hydrogen production from wastes has many advantages compared to various chemical methods. Methodology for characterizing the hydrogen-producing activity of anaerobic mixed cultures is essential for monitoring reactor operation in fermentative hydrogen production, however there is lack of such kind of standardized methodologies. In the present study, a new index, i.e., the maximum specific hydrogen-producing activity (SHAm) of anaerobic mixed cultures, was proposed, and consequently a reliable and simple method, named SHAm test, was developed to determine it. Furthermore, the influences of various parameters on the SHAm value determination of anaerobic mixed cultures were evaluated. Additionally, this SHAm assay was tested for different types of substrates and bacterial inocula. Our results demonstrate that this novel SHAm assay was a rapid, accurate and simple methodology for determining the hydrogen-producing activity of anaerobic mixed cultures. Thus, application of this approach is beneficial to establishing a stable anaerobic hydrogen-producing system. PMID:24912488

  7. The maximum specific hydrogen-producing activity of anaerobic mixed cultures: definition and determination

    NASA Astrophysics Data System (ADS)

    Mu, Yang; Yang, Hou-Yun; Wang, Ya-Zhou; He, Chuan-Shu; Zhao, Quan-Bao; Wang, Yi; Yu, Han-Qing

    2014-06-01

    Fermentative hydrogen production from wastes has many advantages compared to various chemical methods. Methodology for characterizing the hydrogen-producing activity of anaerobic mixed cultures is essential for monitoring reactor operation in fermentative hydrogen production, however there is lack of such kind of standardized methodologies. In the present study, a new index, i.e., the maximum specific hydrogen-producing activity (SHAm) of anaerobic mixed cultures, was proposed, and consequently a reliable and simple method, named SHAm test, was developed to determine it. Furthermore, the influences of various parameters on the SHAm value determination of anaerobic mixed cultures were evaluated. Additionally, this SHAm assay was tested for different types of substrates and bacterial inocula. Our results demonstrate that this novel SHAm assay was a rapid, accurate and simple methodology for determining the hydrogen-producing activity of anaerobic mixed cultures. Thus, application of this approach is beneficial to establishing a stable anaerobic hydrogen-producing system.

  8. Estimating the use of morphometric measurements from museum specimens for sex determination in Mountain Plovers (Charadrius montanus)

    USGS Publications Warehouse

    Iko, W.M.; Dinsmore, S.J.; Knopf, F.L.

    2004-01-01

    The Mountain Plover (Charadrius montanus) is a shorebird species endemic to the dry, terrestrial ecosystems of the Great Plains and southwestern United States. Breeding Bird Survey data suggest that Mountain Plover populations have declined by >60% in the last 30 years. A better understanding of the population dynamics of the Mountain Plover is important in determining future management goals for this species. However, this effort is hampered by the inability to determine the sex of Mountain Plovers accurately under field conditions. In an effort to develop a simple method for sexing plovers in the hand, we measured external morphometric characteristics from 190 museum specimens of adult Mountain Plovers in alternate (breeding) plumage. Logistic regression and discriminant function analyses were performed on 10 external morphometric measurements (lengths of unflattened wing chord, 10th primary, central rectrix, outer rectrix, total head length, exposed culmen, culmen, bill depth, bill width, and tarsus). The results of these analyses indicated that Mountain Plover sexes were similar for all measures except culmen length. However, further analysis determined that culmen length accurately predicted sex in less than two-thirds of the specimens, suggesting that this measure is a poor predictor of sex in Mountain Plovers. Structurally, Mountain Plovers appear to be nearly identical between the sexes, and other methods of sexing birds (e.g., plumage characteristics, behavioral observations, or molecular markers) should be further assessed for devising a simple method for sexing Mountain Plovers under field conditions.

  9. Simultaneous Determination of Ofloxacin and Flavoxate Hydrochloride by Absorption Ratio and Second Derivative UV Spectrophotometry

    PubMed Central

    Attimarad, Mahesh

    2010-01-01

    The objective of this study was to develop simple, precise, accurate and sensitive UV spectrophotometric methods for the simultaneous determination of ofloxacin (OFX) and flavoxate HCl (FLX) in pharmaceutical formulations. The first method is based on absorption ratio method, by formation of Q absorbance equation at 289 nm (λmax of OFX) and 322.4 nm (isoabsorptive point). The linearity range was found to be 1 to 30 μg/ml for FLX and OFX. In the method-II second derivative absorption at 311.4 nm for OFX (zero crossing for FLX) and at 246.2 nm for FLX (zero crossing for OFX) was used for the determination of the drugs and the linearity range was found to be 2 to 30 μg/ml for OFX and 2-75 μg /ml for FLX. The accuracy and precision of the methods were determined and validated statistically. Both the methods showed good reproducibility and recovery with % RSD less than 1.5%. Both the methods were found to be rapid, specific, precise and accurate and can be successfully applied for the routine analysis of OFX and FLX in combined dosage form PMID:24826003

  10. Determination of rivaroxaban in patient's plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS).

    PubMed

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo Dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels.

  11. Configurational entropy: an improvement of the quasiharmonic approximation using configurational temperature.

    PubMed

    Nguyen, Phuong H; Derreumaux, Philippe

    2012-01-14

    One challenge in computational biophysics and biology is to develop methodologies able to estimate accurately the configurational entropy of macromolecules. Among many methods, the quasiharmonic approximation (QH) is most widely used as it is simple in both theory and implementation. However, it has been shown that this method becomes inaccurate by overestimating entropy for systems with rugged free energy landscapes. Here, we propose a simple method to improve the QH approximation, i.e., to reduce QH entropy. We approximate the potential energy landscape of the system by an effective harmonic potential, and request that this potential must produce exactly the configurational temperature of the system. Due to this constraint, the force constants associated with the effective harmonic potential are increased, or equivalently, entropy of motion governed by this effective harmonic potential is reduced. We also introduce the effective configurational temperature concept which can be used as an indicator to check the anharmonicity of the free energy landscape. To validate the new method we compare it with the recently developed expansion approximate method by calculating entropy of one simple model system and two peptides with 3 and 16 amino acids either in gas phase or in explicit solvent. We show that the new method appears to be a good choice in practice as it is a compromise between accuracy and computational speed. A modification of the expansion approximate method is also introduced and advantages are discussed in some detail.

  12. Comparative study of the discrete velocity and lattice Boltzmann methods for rarefied gas flows through irregular channels

    NASA Astrophysics Data System (ADS)

    Su, Wei; Lindsay, Scott; Liu, Haihu; Wu, Lei

    2017-08-01

    Rooted from the gas kinetics, the lattice Boltzmann method (LBM) is a powerful tool in modeling hydrodynamics. In the past decade, it has been extended to simulate rarefied gas flows beyond the Navier-Stokes level, either by using the high-order Gauss-Hermite quadrature, or by introducing the relaxation time that is a function of the gas-wall distance. While the former method, with a limited number of discrete velocities (e.g., D2Q36), is accurate up to the early transition flow regime, the latter method (especially the multiple relaxation time (MRT) LBM), with the same discrete velocities as those used in simulating hydrodynamics (i.e., D2Q9), is accurate up to the free-molecular flow regime in the planar Poiseuille flow. This is quite astonishing in the sense that less discrete velocities are more accurate. In this paper, by solving the Bhatnagar-Gross-Krook kinetic equation accurately via the discrete velocity method, we find that the high-order Gauss-Hermite quadrature cannot describe the large variation in the velocity distribution function when the rarefaction effect is strong, but the MRT-LBM can capture the flow velocity well because it is equivalent to solving the Navier-Stokes equations with an effective shear viscosity. Since the MRT-LBM has only been validated in simple channel flows, and for complex geometries it is difficult to find the effective viscosity, it is necessary to assess its performance for the simulation of rarefied gas flows. Our numerical simulations based on the accurate discrete velocity method suggest that the accuracy of the MRT-LBM is reduced significantly in the simulation of rarefied gas flows through the rough surface and porous media. Our simulation results could serve as benchmarking cases for future development of the LBM for modeling and simulation of rarefied gas flows in complex geometries.

  13. Comparative study of the discrete velocity and lattice Boltzmann methods for rarefied gas flows through irregular channels.

    PubMed

    Su, Wei; Lindsay, Scott; Liu, Haihu; Wu, Lei

    2017-08-01

    Rooted from the gas kinetics, the lattice Boltzmann method (LBM) is a powerful tool in modeling hydrodynamics. In the past decade, it has been extended to simulate rarefied gas flows beyond the Navier-Stokes level, either by using the high-order Gauss-Hermite quadrature, or by introducing the relaxation time that is a function of the gas-wall distance. While the former method, with a limited number of discrete velocities (e.g., D2Q36), is accurate up to the early transition flow regime, the latter method (especially the multiple relaxation time (MRT) LBM), with the same discrete velocities as those used in simulating hydrodynamics (i.e., D2Q9), is accurate up to the free-molecular flow regime in the planar Poiseuille flow. This is quite astonishing in the sense that less discrete velocities are more accurate. In this paper, by solving the Bhatnagar-Gross-Krook kinetic equation accurately via the discrete velocity method, we find that the high-order Gauss-Hermite quadrature cannot describe the large variation in the velocity distribution function when the rarefaction effect is strong, but the MRT-LBM can capture the flow velocity well because it is equivalent to solving the Navier-Stokes equations with an effective shear viscosity. Since the MRT-LBM has only been validated in simple channel flows, and for complex geometries it is difficult to find the effective viscosity, it is necessary to assess its performance for the simulation of rarefied gas flows. Our numerical simulations based on the accurate discrete velocity method suggest that the accuracy of the MRT-LBM is reduced significantly in the simulation of rarefied gas flows through the rough surface and porous media. Our simulation results could serve as benchmarking cases for future development of the LBM for modeling and simulation of rarefied gas flows in complex geometries.

  14. Incorporating the gas analyzer response time in gas exchange computations.

    PubMed

    Mitchell, R R

    1979-11-01

    A simple method for including the gas analyzer response time in the breath-by-breath computation of gas exchange rates is described. The method uses a difference equation form of a model for the gas analyzer in the computation of oxygen uptake and carbon dioxide production and avoids a numerical differentiation required to correct the gas fraction wave forms. The effect of not accounting for analyzer response time is shown to be a 20% underestimation in gas exchange rate. The present method accurately measures gas exchange rate, is relatively insensitive to measurement errors in the analyzer time constant, and does not significantly increase the computation time.

  15. Modeling laser beam diffraction and propagation by the mode-expansion method.

    PubMed

    Snyder, James J

    2007-08-01

    In the mode-expansion method for modeling propagation of a diffracted beam, the beam at the aperture can be expanded as a weighted set of orthogonal modes. The parameters of the expansion modes are chosen to maximize the weighting coefficient of the lowest-order mode. As the beam propagates, its field distribution can be reconstructed from the set of weighting coefficients and the Gouy phase of the lowest-order mode. We have developed a simple procedure to implement the mode-expansion method for propagation through an arbitrary ABCD matrix, and we have demonstrated that it is accurate in comparison with direct calculations of diffraction integrals and much faster.

  16. Shear velocity criterion for incipient motion of sediment

    USGS Publications Warehouse

    Simoes, Francisco J.

    2014-01-01

    The prediction of incipient motion has had great importance to the theory of sediment transport. The most commonly used methods are based on the concept of critical shear stress and employ an approach similar, or identical, to the Shields diagram. An alternative method that uses the movability number, defined as the ratio of the shear velocity to the particle’s settling velocity, was employed in this study. A large amount of experimental data were used to develop an empirical incipient motion criterion based on the movability number. It is shown that this approach can provide a simple and accurate method of computing the threshold condition for sediment motion.

  17. Quantum ring-polymer contraction method: Including nuclear quantum effects at no additional computational cost in comparison to ab initio molecular dynamics

    NASA Astrophysics Data System (ADS)

    John, Christopher; Spura, Thomas; Habershon, Scott; Kühne, Thomas D.

    2016-04-01

    We present a simple and accurate computational method which facilitates ab initio path-integral molecular dynamics simulations, where the quantum-mechanical nature of the nuclei is explicitly taken into account, at essentially no additional computational cost in comparison to the corresponding calculation using classical nuclei. The predictive power of the proposed quantum ring-polymer contraction method is demonstrated by computing various static and dynamic properties of liquid water at ambient conditions using density functional theory. This development will enable routine inclusion of nuclear quantum effects in ab initio molecular dynamics simulations of condensed-phase systems.

  18. A Solution Adaptive Technique Using Tetrahedral Unstructured Grids

    NASA Technical Reports Server (NTRS)

    Pirzadeh, Shahyar Z.

    2000-01-01

    An adaptive unstructured grid refinement technique has been developed and successfully applied to several three dimensional inviscid flow test cases. The method is based on a combination of surface mesh subdivision and local remeshing of the volume grid Simple functions of flow quantities are employed to detect dominant features of the flowfield The method is designed for modular coupling with various error/feature analyzers and flow solvers. Several steady-state, inviscid flow test cases are presented to demonstrate the applicability of the method for solving practical three-dimensional problems. In all cases, accurate solutions featuring complex, nonlinear flow phenomena such as shock waves and vortices have been generated automatically and efficiently.

  19. Accurate analysis and visualization of cardiac (11)C-PIB uptake in amyloidosis with semiautomatic software.

    PubMed

    Kero, Tanja; Lindsjö, Lars; Sörensen, Jens; Lubberink, Mark

    2016-08-01

    (11)C-PIB PET is a promising non-invasive diagnostic tool for cardiac amyloidosis. Semiautomatic analysis of PET data is now available but it is not known how accurate these methods are for amyloid imaging. The aim of this study was to evaluate the feasibility of one semiautomatic software tool for analysis and visualization of (11)C-PIB left ventricular retention index (RI) in cardiac amyloidosis. Patients with systemic amyloidosis and cardiac involvement (n = 10) and healthy controls (n = 5) were investigated with dynamic (11)C-PIB PET. Two observers analyzed the PET studies with semiautomatic software to calculate the left ventricular RI of (11)C-PIB and to create parametric images. The mean RI at 15-25 min from the semiautomatic analysis was compared with RI based on manual analysis and showed comparable values (0.056 vs 0.054 min(-1) for amyloidosis patients and 0.024 vs 0.025 min(-1) in healthy controls; P = .78) and the correlation was excellent (r = 0.98). Inter-reader reproducibility also was excellent (intraclass correlation coefficient, ICC > 0.98). Parametric polarmaps and histograms made visual separation of amyloidosis patients and healthy controls fast and simple. Accurate semiautomatic analysis of cardiac (11)C-PIB RI in amyloidosis patients is feasible. Parametric polarmaps and histograms make visual interpretation fast and simple.

  20. VALIDATION OF MICROSATELLITE MARKERS FOR USE IN GENOTYPING POLYCLONAL PLASMODIUM FALCIPARUM INFECTIONS

    PubMed Central

    GREENHOUSE, BRYAN; MYRICK, ALISSA; DOKOMAJILAR, CHRISTIAN; WOO, JONATHAN M.; CARLSON, ELAINE J.; ROSENTHAL, PHILIP J.; DORSEY, GRANT

    2006-01-01

    Genotyping methods for Plasmodium falciparum drug efficacy trials have not been standardized and may fail to accurately distinguish recrudescence from new infection, especially in high transmission areas where polyclonal infections are common. We developed a simple method for genotyping using previously identified microsatellites and capillary electrophoresis, validated this method using mixtures of laboratory clones, and applied the method to field samples. Two microsatellite markers produced accurate results for single-clone but not polyclonal samples. Four other microsatellite markers were as sensitive as, and more specific than, commonly used genotyping techniques based on merozoite surface proteins 1 and 2. When applied to samples from 15 patients in Burkina Faso with recurrent parasitemia after treatment with sulphadoxine-pyrimethamine, the addition of these four microsatellite markers to msp1 and msp2 genotyping resulted in a reclassification of outcomes that strengthened the association between dhfr 59R, an anti-folate resistance mutation, and recrudescence (P = 0.31 versus P = 0.03). Four microsatellite markers performed well on polyclonal samples and may provide a valuable addition to genotyping for clinical drug efficacy studies in high transmission areas. PMID:17123974

  1. Purification of Single-Stranded cDNA Based on RNA Degradation Treatment and Adsorption Chromatography.

    PubMed

    Trujillo-Esquivel, Elías; Franco, Bernardo; Flores-Martínez, Alberto; Ponce-Noyola, Patricia; Mora-Montes, Héctor M

    2016-08-02

    Analysis of gene expression is a common research tool to study networks controlling gene expression, the role of genes with unknown function, and environmentally induced responses of organisms. Most of the analytical tools used to analyze gene expression rely on accurate cDNA synthesis and quantification to obtain reproducible and quantifiable results. Thus far, most commercial kits for isolation and purification of cDNA target double-stranded molecules, which do not accurately represent the abundance of transcripts. In the present report, we provide a simple and fast method to purify single-stranded cDNA, exhibiting high purity and yield. This method is based on the treatment with RNase H and RNase A after cDNA synthesis, followed by separation in silica spin-columns and ethanol precipitation. In addition, our method avoids the use of DNase I to eliminate genomic DNA from RNA preparations, which improves cDNA yield. As a case report, our method proved to be useful in the purification of single-stranded cDNA from the pathogenic fungus Sporothrix schenckii.

  2. Performance of quantum Monte Carlo for calculating molecular bond lengths

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cleland, Deidre M., E-mail: deidre.cleland@csiro.au; Per, Manolo C., E-mail: manolo.per@csiro.au

    2016-03-28

    This work investigates the accuracy of real-space quantum Monte Carlo (QMC) methods for calculating molecular geometries. We present the equilibrium bond lengths of a test set of 30 diatomic molecules calculated using variational Monte Carlo (VMC) and diffusion Monte Carlo (DMC) methods. The effect of different trial wavefunctions is investigated using single determinants constructed from Hartree-Fock (HF) and Density Functional Theory (DFT) orbitals with LDA, PBE, and B3LYP functionals, as well as small multi-configurational self-consistent field (MCSCF) multi-determinant expansions. When compared to experimental geometries, all DMC methods exhibit smaller mean-absolute deviations (MADs) than those given by HF, DFT, and MCSCF.more » The most accurate MAD of 3 ± 2 × 10{sup −3} Å is achieved using DMC with a small multi-determinant expansion. However, the more computationally efficient multi-determinant VMC method has a similar MAD of only 4.0 ± 0.9 × 10{sup −3} Å, suggesting that QMC forces calculated from the relatively simple VMC algorithm may often be sufficient for accurate molecular geometries.« less

  3. Centrifugal techniques for measuring saturated hydraulic conductivity

    USGS Publications Warehouse

    Nimmo, John R.; Mello, Karen A.

    1991-01-01

    Centrifugal force is an alternative to large pressure gradients for the measurement of low values of saturated hydraulic conductivity (Ksat). With a head of water above a porous medium in a centrifuge bucket, both constant-head and falling-head measurements are practical at forces up to at least 1800 times normal gravity. Darcy's law applied to the known centrifugal potential leads to simple formulas for Ksat that are analogous to those used in the standard gravity-driven constant- and falling-head methods. Both centrifugal methods were tested on several fine-textured samples of soil and ceramic with Ksat between about 10−10 and 10−9 m/s. The results were compared to falling-head gravity measurements. The comparison shows most measurements agreeing to within 20% for a given sample, much of the variation probably resulting from run-to-run changes in sample structure. The falling-head centrifuge method proved to be especially simple in design and operation and was more accurate than the constant-head method. With modified apparatus, Ksat measurements less than 10−10 m/s should be attainable.

  4. Estimation of postmortem interval through albumin in CSF by simple dye binding method.

    PubMed

    Parmar, Ankita K; Menon, Shobhana K

    2015-12-01

    Estimation of postmortem interval is a very important question in some medicolegal investigations. For the precise estimation of postmortem interval, there is a need of a method which can give accurate estimation. Bromocresol green (BCG) is a simple dye binding method and widely used in routine practice. Application of this method in forensic practice may bring revolutionary changes. In this study, cerebrospinal fluid was aspirated from cisternal puncture from 100 autopsies. A study was carried out on concentration of albumin with respect to postmortem interval. After death, albumin present in CSF undergoes changes, after 72 h of death, concentration of albumin has become 0.012 mM, and this decrease was linear from 2 h to 72 h. An important relationship was found between albumin concentration and postmortem interval with an error of ± 1-4h. The study concludes that CSF albumin can be a useful and significant parameter in estimation of postmortem interval. Copyright © 2015 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  5. Analytical detection and method development of anticancer drug Gemcitabine HCl using gold nanoparticles.

    PubMed

    Menon, Shobhana K; Mistry, Bhoomika R; Joshi, Kuldeep V; Sutariya, Pinkesh G; Patel, Ravindra V

    2012-08-01

    A simple, rapid, cost effective and extractive UV spectrophotometric method was developed for the determination of Gemcitabine HCl (GMCT) in bulk drug and pharmaceutical formulation. It was based on UV spectrophotometric measurements in which the drug reacts with gold nanoparticles (AuNP) and changes the original colour of AuNP and forms a dark blue coloured solution which exhibits absorption maximum at 688nm. The apparent molar absorptivity and Sandell's sensitivity coefficient were found to be 3.95×10(-5)lmol(-1)cm(-1) and 0.060μgcm(-2) respectively. Beer's law was obeyed in the concentration range of 2.0-40μgml(-1). This method was tested and validated for various parameters according to ICH guidelines. The proposed method was successfully applied for the determination of GMCT in pharmaceutical formulation (parental formulation). The results demonstrated that the procedure is accurate, precise and reproducible (relative standard deviation <2%). As it is simple, cheap and less time consuming, it can be suitably applied for the estimation of GMCT in dosage forms. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Use of MEMs and optical sensors for closed loop heliostat control

    NASA Astrophysics Data System (ADS)

    Harper, Paul Julian; Dreijer, Janto; Malan, Karel; Larmuth, James; Gauche, Paul

    2016-05-01

    The Helio 100 project at STERG (Stellenbosch Solar Thermal Research Group) aims to help reduce the cost of Concentrated Solar Thermal plants by deploying large numbers of small (1x2 m) low cost heliostats. One of the methods employed to reduce the cost of the heliostat field is to have a field that requires no site preparation (grading, leveling, vegetation clearance) and no expensive foundations or concrete pouring for each individual heliostat base. This implies that the heliostat pod frames and vertical mounts might be slightly out of vertical, and the normal method of dead reckoning using accurately surveyed and aligned heliostat bases cannot be used. This paper describes a combination of MEMs and optical sensors on the back of the heliostat, that together with a simple machine learning approach, give accurate and reproducible azimuth and elevation information for the heliostat plane. Initial experiments were done with an android phone mounted on the back of a heliostat as it was a readily available platform combining accelerometers' and camera into one programmable package. It was found quite easy to determine the pointing angle of the heliostat to within 1 milliradian using the rear facing camera and correlating known heliostat angles with target image features on the ground. We also tested the accuracy at various image resolutions by halving the image size successively till the feature detection failed. This showed that even a VGA (640x480) resolution image could give mean errors of 1.5 milliradian. The optical technique is exceedingly simple and does not use any camera calibration, angular reconstruction or knowledge of heliostat drive geometry. We also tested the ability of the 3d accelerometers to determine angle, but this was coarser than the camera and only accurate to around 10 milliradians.

  7. Realistic absorption coefficient of each individual film in a multilayer architecture

    NASA Astrophysics Data System (ADS)

    Cesaria, M.; Caricato, A. P.; Martino, M.

    2015-02-01

    A spectrophotometric strategy, termed multilayer-method (ML-method), is presented and discussed to realistically calculate the absorption coefficient of each individual layer embedded in multilayer architectures without reverse engineering, numerical refinements and assumptions about the layer homogeneity and thickness. The strategy extends in a non-straightforward way a consolidated route, already published by the authors and here termed basic-method, able to accurately characterize an absorbing film covering transparent substrates. The ML-method inherently accounts for non-measurable contribution of the interfaces (including multiple reflections), describes the specific film structure as determined by the multilayer architecture and used deposition approach and parameters, exploits simple mathematics, and has wide range of applicability (high-to-weak absorption regions, thick-to-ultrathin films). Reliability tests are performed on films and multilayers based on a well-known material (indium tin oxide) by deliberately changing the film structural quality through doping, thickness-tuning and underlying supporting-film. Results are found consistent with information obtained by standard (optical and structural) analysis, the basic-method and band gap values reported in the literature. The discussed example-applications demonstrate the ability of the ML-method to overcome the drawbacks commonly limiting an accurate description of multilayer architectures.

  8. Development and Validation of Different Ultraviolet-Spectrophotometric Methods for the Estimation of Besifloxacin in Different Simulated Body Fluids.

    PubMed

    Singh, C L; Singh, A; Kumar, S; Kumar, M; Sharma, P K; Majumdar, D K

    2015-01-01

    In the present study a simple, accurate, precise, economical and specific UV-spectrophotometric method for estimation of besifloxacin in bulk and in different pharmaceutical formulation has been developed. The drug shows maximum λmax289 nm in distilled water, simulated tears and phosphate buffer saline. The linearity range of developed methods were in the range of 3-30 μg/ml of drug with a correlation coefficient (r(2)) 0.9992, 0.9989 and 0.9984 with respect to distilled water, simulated tears and phosphate buffer saline, respectively. Reproducibility by repeating methods as %RSD were found to be less than 2%. The limit of detection in different media was found to be 0.62, 0.72 and 0.88 μg/ml, respectively. The limit of quantification was found to be 1.88, 2.10, 2.60 μg/ml, respectively. The proposed method was validated statically according to International Conference on Harmonization guidelines with respect to specificity, linearity, range, accuracy, precision and robustness. The proposed methods of validation were found to be accurate and highly specific for the estimation of besifloxacin in different pharmaceutical formulations.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vargas, Asticio; Center for Optics and Photonics, Universidad de Concepción, Casilla 4016, Concepción; Mar Sánchez-López, María del

    Multiple-beam Fabry-Perot (FP) interferences occur in liquid crystal retarders (LCR) devoid of an antireflective coating. In this work, a highly accurate method to obtain the spectral retardance of such devices is presented. On the basis of a simple model of the LCR that includes FP effects and by using a voltage transfer function, we show how the FP features in the transmission spectrum can be used to accurately retrieve the ordinary and extraordinary spectral phase delays, and the voltage dependence of the latter. As a consequence, the modulation characteristics of the device are fully determined with high accuracy by meansmore » of a few off-state physical parameters which are wavelength-dependent, and a single voltage transfer function that is valid within the spectral range of characterization.« less

  10. Mean centering of ratio spectra and concentration augmented classical least squares in a comparative approach for quantitation of spectrally overlapped bands of antihypertensives in formulations

    NASA Astrophysics Data System (ADS)

    Hegazy, Maha Abdel Monem; Fayez, Yasmin Mohammed

    2015-04-01

    Two different methods manipulating spectrophotometric data have been developed, validated and compared. One is capable of removing the signal of any interfering components at the selected wavelength of the component of interest (univariate). The other includes more variables and extracts maximum information to determine the component of interest in the presence of other components (multivariate). The applied methods are smart, simple, accurate, sensitive, precise and capable of determination of spectrally overlapped antihypertensives; hydrochlorothiazide (HCT), irbesartan (IRB) and candesartan (CAN). Mean centering of ratio spectra (MCR) and concentration residual augmented classical least-squares method (CRACLS) were developed and their efficiency was compared. CRACLS is a simple method that is capable of extracting the pure spectral profiles of each component in a mixture. Correlation was calculated between the estimated and pure spectra and was found to be 0.9998, 0.9987 and 0.9992 for HCT, IRB and CAN, respectively. The methods were successfully determined the three components in bulk powder, laboratory-prepared mixtures, and combined dosage forms. The results obtained were compared statistically with each other and to those of the official methods.

  11. A simple spectrophotometric method for determination of zirconium or hafnium in selected molybdenum-base alloys

    NASA Technical Reports Server (NTRS)

    Dupraw, W. A.

    1972-01-01

    A simple analytical procedure is described for accurately and precisely determining the zirconium or hafnium content of molybdenum-base alloys. The procedure is based on the reaction of the reagent Arsenazo III with zirconium or hafnium in strong hydrochloric acid solution. The colored complexes of zirconium or hafnium are formed in the presence of molybdenum. Titanium or rhenium in the alloy have no adverse effect on the zirconium or hafnium complex at the following levels in the selected aliquot: Mo, 10 mg; Re, 10 mg; Ti, 1 mg. The spectrophotometric measurement of the zirconium or hafnium complex is accomplished without prior separation with a relative standard deviation of 1.3 to 2.7 percent.

  12. Wide dynamic logarithmic InGaAs sensor suitable for eye-safe active imaging

    NASA Astrophysics Data System (ADS)

    Ni, Yang; Bouvier, Christian; Arion, Bogdan; Noguier, Vincent

    2016-05-01

    In this paper, we present a simple method to analyze the injection efficiency of the photodiode interface circuit under fast shuttering conditions for active Imaging applications. This simple model has been inspired from the companion model for reactive elements largely used in CAD. In this paper, we demonstrate that traditional CTIA photodiode interface is not adequate for active imaging where fast and precise shuttering operation is necessary. Afterwards we present a direct amplification based photodiode interface which can provide an accurate and fast shuttering operation on photodiode. These considerations have been used in NIT's newly developed ROIC and corresponding SWIR sensors both in VGA 15um pitch (NSC1201) and also in QVGA 25um pitch (NSC1401).

  13. Ultrasonic technique for characterizing skin burns

    DOEpatents

    Goans, Ronald E.; Cantrell, Jr., John H.; Meyers, F. Bradford; Stambaugh, Harry D.

    1978-01-01

    This invention, a method for ultrasonically determining the depth of a skin burn, is based on the finding that the acoustical impedance of burned tissue differs sufficiently from that of live tissue to permit ultrasonic detection of the interface between the burn and the underlying unburned tissue. The method is simple, rapid, and accurate. As compared with conventional practice, it provides the important advantage of permitting much earlier determination of whether a burn is of the first, second, or third degree. In the case of severe burns, the usual two - to three-week delay before surgery may be reduced to about 3 days or less.

  14. Are artificial opals non-close-packed fcc structures?

    NASA Astrophysics Data System (ADS)

    García-Santamaría, F.; Braun, P. V.

    2007-06-01

    The authors report a simple experimental method to accurately measure the volume fraction of artificial opals. The results are modeled using several methods, and they find that some of the most common yield very inaccurate results. Both finite size and substrate effects play an important role in calculations of the volume fraction. The experimental results show that the interstitial pore volume is 4%-15% larger than expected for close-packed structures. Consequently, calculations performed in previous work relating the amount of material synthesized in the opal interstices with the optical properties may need revision, especially in the case of high refractive index materials.

  15. Measuring Distance of Fuzzy Numbers by Trapezoidal Fuzzy Numbers

    NASA Astrophysics Data System (ADS)

    Hajjari, Tayebeh

    2010-11-01

    Fuzzy numbers and more generally linguistic values are approximate assessments, given by experts and accepted by decision-makers when obtaining value that is more accurate is impossible or unnecessary. Distance between two fuzzy numbers plays an important role in linguistic decision-making. It is reasonable to define a fuzzy distance between fuzzy objects. To achieve this aim, the researcher presents a new distance measure for fuzzy numbers by means of improved centroid distance method. The metric properties are also studied. The advantage is the calculation of the proposed method is far simple than previous approaches.

  16. Fast and accurate computation of system matrix for area integral model-based algebraic reconstruction technique

    NASA Astrophysics Data System (ADS)

    Zhang, Shunli; Zhang, Dinghua; Gong, Hao; Ghasemalizadeh, Omid; Wang, Ge; Cao, Guohua

    2014-11-01

    Iterative algorithms, such as the algebraic reconstruction technique (ART), are popular for image reconstruction. For iterative reconstruction, the area integral model (AIM) is more accurate for better reconstruction quality than the line integral model (LIM). However, the computation of the system matrix for AIM is more complex and time-consuming than that for LIM. Here, we propose a fast and accurate method to compute the system matrix for AIM. First, we calculate the intersection of each boundary line of a narrow fan-beam with pixels in a recursive and efficient manner. Then, by grouping the beam-pixel intersection area into six types according to the slopes of the two boundary lines, we analytically compute the intersection area of the narrow fan-beam with the pixels in a simple algebraic fashion. Overall, experimental results show that our method is about three times faster than the Siddon algorithm and about two times faster than the distance-driven model (DDM) in computation of the system matrix. The reconstruction speed of our AIM-based ART is also faster than the LIM-based ART that uses the Siddon algorithm and DDM-based ART, for one iteration. The fast reconstruction speed of our method was accomplished without compromising the image quality.

  17. A rapid method of accurate detection and differentiation of Newcastle disease virus pathotypes by demonstrating multiple bands in degenerate primer based nested RT-PCR.

    PubMed

    Desingu, P A; Singh, S D; Dhama, K; Kumar, O R Vinodh; Singh, R; Singh, R K

    2015-02-01

    A rapid and accurate method of detection and differentiation of virulent and avirulent Newcastle disease virus (NDV) pathotypes was developed. The NDV detection was carried out for different domestic avian field isolates and pigeon paramyxo virus-1 (25 field isolates and 9 vaccine strains) by using APMV-I "fusion" (F) gene Class II specific external primer A and B (535bp), internal primer C and D (238bp) based reverses transcriptase PCR (RT-PCR). The internal degenerative reverse primer D is specific for F gene cleavage position of virulent strain of NDV. The nested RT-PCR products of avirulent strains showed two bands (535bp and 424bp) while virulent strains showed four bands (535bp, 424bp, 349bp and 238bp) on agar gel electrophoresis. This is the first report regarding development and use of degenerate primer based nested RT-PCR for accurate detection and differentiation of NDV pathotypes by demonstrating multiple PCR band patterns. Being a rapid, simple, and economical test, the developed method could serve as a valuable alternate diagnostic tool for characterizing NDV isolates and carrying out molecular epidemiological surveillance studies for this important pathogen of poultry. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Stochastic simulation of enzyme-catalyzed reactions with disparate timescales.

    PubMed

    Barik, Debashis; Paul, Mark R; Baumann, William T; Cao, Yang; Tyson, John J

    2008-10-01

    Many physiological characteristics of living cells are regulated by protein interaction networks. Because the total numbers of these protein species can be small, molecular noise can have significant effects on the dynamical properties of a regulatory network. Computing these stochastic effects is made difficult by the large timescale separations typical of protein interactions (e.g., complex formation may occur in fractions of a second, whereas catalytic conversions may take minutes). Exact stochastic simulation may be very inefficient under these circumstances, and methods for speeding up the simulation without sacrificing accuracy have been widely studied. We show that the "total quasi-steady-state approximation" for enzyme-catalyzed reactions provides a useful framework for efficient and accurate stochastic simulations. The method is applied to three examples: a simple enzyme-catalyzed reaction where enzyme and substrate have comparable abundances, a Goldbeter-Koshland switch, where a kinase and phosphatase regulate the phosphorylation state of a common substrate, and coupled Goldbeter-Koshland switches that exhibit bistability. Simulations based on the total quasi-steady-state approximation accurately capture the steady-state probability distributions of all components of these reaction networks. In many respects, the approximation also faithfully reproduces time-dependent aspects of the fluctuations. The method is accurate even under conditions of poor timescale separation.

  19. Field Method for Measuring the Shrinkage/Swelling Dynamics of Cracks Using a Low-Cost ``Crack-o-meter''

    NASA Astrophysics Data System (ADS)

    Stewart, R. D.; Abou Najm, M. R.; Rupp, D. E.; Selker, J. S.

    2010-12-01

    Shrinking/swelling soils are characterized by transient crack networks which function as dominant controls on the partitioning of surface and subsurface flow, the rate and depth of percolation, and evaporation rates. For such soils, understanding the dynamics of cracks is critical to accurately quantify their influence on groundwater recharge, stream-flow generation, and solute transport, among other component of a site’s hydrology. We propose a low-cost method for measuring transient crack-volume using a sealed plastic bag connected by a hose to a PVC standpipe. The empty bag is placed into the crack, and then water is added via the standpipe, until the bag has expanded to the boundaries of the crack and some water remains in the standpipe. As the crack shrinks or swells, its volume changes, causing water displacement within the bag, which is measured as a corresponding change in water level in the standpipe. An automated level logger within the standpipe is used to record changes in water level, which are converted to volumetric changes from the known internal cross-sectional area of the standpipe. The volume of water filling the bag is accurately measured at the start and completion of the experiment (to check for leakage). Adding the startup volume to the cumulative temporal volumetric change in the standpipe provides a simple and accurate method for monitoring transient crack volume. Currently, the design is undergoing preliminary testing in a field site in Ninhue, Chile, and field and laboratory testing in Corvallis, Oregon. Initial results from the Chilean field site suggest that the crack-o-meters are responding to the closing of cracks, but further effort is needed to calibrate and validate the results. We hope that these low-cost “crack-o-meters” will become useful and simple tools for researchers to quantify temporal changes in crack volume with the objective of incorporating these results into hydrological modeling efforts.

  20. Quantitative Analysis of Clopidogrel Bisulphate and Aspirin by First Derivative Spectrophotometric Method in Tablets

    PubMed Central

    Game, Madhuri D.; Gabhane, K. B.; Sakarkar, D. M.

    2010-01-01

    A simple, accurate and precise spectrophotometric method has been developed for simultaneous estimation of clopidogrel bisulphate and aspirin by employing first order derivative zero crossing method. The first order derivative absorption at 232.5 nm (zero cross point of aspirin) was used for clopidogrel bisulphate and 211.3 nm (zero cross point of clopidogrel bisulphate) for aspirin.Both the drugs obeyed linearity in the concentration range of 5.0 μg/ml to 25.0 μg/ml (correlation coefficient r2<1). No interference was found between both determined constituents and those of matrix. The method was validated statistically and recovery studies were carried out to confirm the accuracy of the method. PMID:21969765

  1. Distortion Correction of OCT Images of the Crystalline Lens: GRIN Approach

    PubMed Central

    Siedlecki, Damian; de Castro, Alberto; Gambra, Enrique; Ortiz, Sergio; Borja, David; Uhlhorn, Stephen; Manns, Fabrice; Marcos, Susana; Parel, Jean-Marie

    2012-01-01

    Purpose To propose a method to correct Optical Coherence Tomography (OCT) images of posterior surface of the crystalline lens incorporating its gradient index (GRIN) distribution and explore its possibilities for posterior surface shape reconstruction in comparison to existing methods of correction. Methods 2-D images of 9 human lenses were obtained with a time-domain OCT system. The shape of the posterior lens surface was corrected using the proposed iterative correction method. The parameters defining the GRIN distribution used for the correction were taken from a previous publication. The results of correction were evaluated relative to the nominal surface shape (accessible in vitro) and compared to the performance of two other existing methods (simple division, refraction correction: assuming a homogeneous index). Comparisons were made in terms of posterior surface radius, conic constant, root mean square, peak to valley and lens thickness shifts from the nominal data. Results Differences in the retrieved radius and conic constant were not statistically significant across methods. However, GRIN distortion correction with optimal shape GRIN parameters provided more accurate estimates of the posterior lens surface, in terms of RMS and peak values, with errors less than 6μm and 13μm respectively, on average. Thickness was also more accurately estimated with the new method, with a mean discrepancy of 8μm. Conclusions The posterior surface of the crystalline lens and lens thickness can be accurately reconstructed from OCT images, with the accuracy improving with an accurate model of the GRIN distribution. The algorithm can be used to improve quantitative knowledge of the crystalline lens from OCT imaging in vivo. Although the improvements over other methods are modest in 2-D, it is expected that 3-D imaging will fully exploit the potential of the technique. The method will also benefit from increasing experimental data of GRIN distribution in the lens of larger populations. PMID:22466105

  2. Development and Validation of Liquid Chromatographic Method for Estimation of Naringin in Nanoformulation

    PubMed Central

    Musmade, Kranti P.; Trilok, M.; Dengale, Swapnil J.; Bhat, Krishnamurthy; Reddy, M. S.; Musmade, Prashant B.; Udupa, N.

    2014-01-01

    A simple, precise, accurate, rapid, and sensitive reverse phase high performance liquid chromatography (RP-HPLC) method with UV detection has been developed and validated for quantification of naringin (NAR) in novel pharmaceutical formulation. NAR is a polyphenolic flavonoid present in most of the citrus plants having variety of pharmacological activities. Method optimization was carried out by considering the various parameters such as effect of pH and column. The analyte was separated by employing a C18 (250.0 × 4.6 mm, 5 μm) column at ambient temperature in isocratic conditions using phosphate buffer pH 3.5: acetonitrile (75 : 25% v/v) as mobile phase pumped at a flow rate of 1.0 mL/min. UV detection was carried out at 282 nm. The developed method was validated according to ICH guidelines Q2(R1). The method was found to be precise and accurate on statistical evaluation with a linearity range of 0.1 to 20.0 μg/mL for NAR. The intra- and interday precision studies showed good reproducibility with coefficients of variation (CV) less than 1.0%. The mean recovery of NAR was found to be 99.33 ± 0.16%. The proposed method was found to be highly accurate, sensitive, and robust. The proposed liquid chromatographic method was successfully employed for the routine analysis of said compound in developed novel nanopharmaceuticals. The presence of excipients did not show any interference on the determination of NAR, indicating method specificity. PMID:26556205

  3. Z-scan theoretical and experimental studies for accurate measurements of the nonlinear refractive index and absorption of optical glasses near damage threshold

    NASA Astrophysics Data System (ADS)

    Olivier, Thomas; Billard, Franck; Akhouayri, Hassan

    2004-06-01

    Self-focusing is one of the dramatic phenomena that may occur during the propagation of a high power laser beam in a nonlinear material. This phenomenon leads to a degradation of the wave front and may also lead to a photoinduced damage of the material. Realistic simulations of the propagation of high power laser beams require an accurate knowledge of the nonlinear refractive index γ. In the particular case of fused silica and in the nanosecond regime, it seems that electronic mechanisms as well as electrostriction and thermal effects can lead to a significant refractive index variation. Compared to the different methods used to measure this parmeter, the Z-scan method is simple, offers a good sensitivity and may give absolute measurements if the incident beam is accurately studied. However, this method requires a very good knowledge of the incident beam and of its propagation inside a nonlinear sample. We used a split-step propagation algorithm to simlate Z-scan curves for arbitrary beam shape, sample thickness and nonlinear phase shift. According to our simulations and a rigorous analysis of the Z-scan measured signal, it appears that some abusive approximations lead to very important errors. Thus, by reducing possible errors on the interpretation of Z-scan experimental studies, we performed accurate measurements of the nonlinear refractive index of fused silica that show the significant contribution of nanosecond mechanisms.

  4. Vibratory high pressure coal feeder having a helical ramp

    DOEpatents

    Farber, Gerald

    1978-01-01

    Apparatus and method for feeding powdered coal from a helical ramp into a high pressure, heated, reactor tube containing hydrogen for hydrogenating the coal and/or for producing useful products from coal. To this end, the helical ramp is vibrated to feed the coal cleanly at an accurately controlled rate in a simple reliable and trouble-free manner that eliminates complicated and expensive screw feeders, and/or complicated and expensive seals, bearings and fully rotating parts.

  5. A simple real-time polymerase chain reaction (PCR)-based assay for authentication of the Chinese Panax ginseng cultivar Damaya from a local ginseng population.

    PubMed

    Wang, H; Wang, J; Li, G

    2016-06-27

    Panax ginseng is one of the most important medicinal plants in the Orient. Owing to its increasing demand in the world market, cultivated ginseng has become the main source of medicinal material. Among the Chinese ginseng cultivars, Damaya commands higher prices and is grown in significant proportions among the local ginseng population. Due to the lack of rapid and accurate authentication methods, Damaya is distributed among different cultivars in the local ginseng population in China. Here, we identified a unique, Damaya-specific single nucleotide polymorphism (SNP) site present in the second intron of mitochondrial cytochrome c oxidase subunit 2 (cox2). Based on this SNP, a Damaya cultivar-specific primer was designed and an allele-specific polymerase chain reaction (PCR) was optimized for the effective molecular authentication of Damaya. We designed a method by combining a simple DNA isolation method with real-time allele-specific PCR using SYBR Green I fluorescent dye, and proved its efficacy in clearly discriminated Damaya cultivar from other Chinese ginseng cultivars according to the allelic discrimination analysis. Hence, this study provides a simple and rapid assay for the differentiation and conservation of Damaya from the local Chinese ginseng population.

  6. Prediction of Petermann I and II Spot Sizes for Single-mode Dispersion-shifted and Dispersion-flattened Fibers by a Simple Technique

    NASA Astrophysics Data System (ADS)

    Kamila, Kiranmay; Panda, Anup Kumar; Gangopadhyay, Sankar

    2013-09-01

    Employing the series expression for the fundamental modal field of dispersion-shifted trapezoidal and dispersion-flattened graded and step W fibers, we present simple but accurate analytical expressions for Petermann I and II spot sizes of such kind of fibers. Choosing some typical dispersion-shifted trapezoidal and dispersion-flattened graded and step W fibers as examples, we show that our estimations match excellently with the exact numerical results. The evaluation of the concerned propagation parameters by our formalism needs very little computations. This accurate but simple formalism will benefit the system engineers working in the field of all optical technology.

  7. Simultaneous Spectrophotometric Estimation of Nitazoxanide and Ofloxacin in Tablets

    PubMed Central

    Game, Madhuri D.; Sakarkar, D. M.

    2011-01-01

    Two simple, accurate and precise spectrophotometric methods have been developed for simultaneous determination of nitazoxanide and ofloxacin in tablets. Method I is Q-absorbance ratio method which involves Q-absorbance at isobestic point (306.25 nm) and max (347.5 nm) of nitazoxanide, while method II is two wavelength method, where 244.6 nm and 273.0 nm were selected as 1 and 2 for determination of nitazoxanide and 294.3 nm and 388.1 nm were selected as 3 and 4 for determination of ofloxacin. Both drugs obeyed the Beer's law in the concentration range 2-30 μg/ml,correlation coefficient (r2<1). Both methods were validated statistically and recovery studies were carried out to confirm the accuracy. Commercial tablet formulation was successfully analyzed using the developed methods. PMID:22131624

  8. Bio-inspired adaptive feedback error learning architecture for motor control.

    PubMed

    Tolu, Silvia; Vanegas, Mauricio; Luque, Niceto R; Garrido, Jesús A; Ros, Eduardo

    2012-10-01

    This study proposes an adaptive control architecture based on an accurate regression method called Locally Weighted Projection Regression (LWPR) and on a bio-inspired module, such as a cerebellar-like engine. This hybrid architecture takes full advantage of the machine learning module (LWPR kernel) to abstract an optimized representation of the sensorimotor space while the cerebellar component integrates this to generate corrective terms in the framework of a control task. Furthermore, we illustrate how the use of a simple adaptive error feedback term allows to use the proposed architecture even in the absence of an accurate analytic reference model. The presented approach achieves an accurate control with low gain corrective terms (for compliant control schemes). We evaluate the contribution of the different components of the proposed scheme comparing the obtained performance with alternative approaches. Then, we show that the presented architecture can be used for accurate manipulation of different objects when their physical properties are not directly known by the controller. We evaluate how the scheme scales for simulated plants of high Degrees of Freedom (7-DOFs).

  9. Distortion correction of OCT images of the crystalline lens: gradient index approach.

    PubMed

    Siedlecki, Damian; de Castro, Alberto; Gambra, Enrique; Ortiz, Sergio; Borja, David; Uhlhorn, Stephen; Manns, Fabrice; Marcos, Susana; Parel, Jean-Marie

    2012-05-01

    To propose a method to correct optical coherence tomography (OCT) images of posterior surface of the crystalline lens incorporating its gradient index (GRIN) distribution and explore its possibilities for posterior surface shape reconstruction in comparison to existing methods of correction. Two-dimensional images of nine human lenses were obtained with a time-domain OCT system. The shape of the posterior lens surface was corrected using the proposed iterative correction method. The parameters defining the GRIN distribution used for the correction were taken from a previous publication. The results of correction were evaluated relative to the nominal surface shape (accessible in vitro) and compared with the performance of two other existing methods (simple division, refraction correction: assuming a homogeneous index). Comparisons were made in terms of posterior surface radius, conic constant, root mean square, peak to valley, and lens thickness shifts from the nominal data. Differences in the retrieved radius and conic constant were not statistically significant across methods. However, GRIN distortion correction with optimal shape GRIN parameters provided more accurate estimates of the posterior lens surface in terms of root mean square and peak values, with errors <6 and 13 μm, respectively, on average. Thickness was also more accurately estimated with the new method, with a mean discrepancy of 8 μm. The posterior surface of the crystalline lens and lens thickness can be accurately reconstructed from OCT images, with the accuracy improving with an accurate model of the GRIN distribution. The algorithm can be used to improve quantitative knowledge of the crystalline lens from OCT imaging in vivo. Although the improvements over other methods are modest in two dimension, it is expected that three-dimensional imaging will fully exploit the potential of the technique. The method will also benefit from increasing experimental data of GRIN distribution in the lens of larger populations.

  10. An optimized knife-edge method for on-orbit MTF estimation of optical sensors using powell parameter fitting

    NASA Astrophysics Data System (ADS)

    Han, Lu; Gao, Kun; Gong, Chen; Zhu, Zhenyu; Guo, Yue

    2017-08-01

    On-orbit Modulation Transfer Function (MTF) is an important indicator to evaluate the performance of the optical remote sensors in a satellite. There are many methods to estimate MTF, such as pinhole method, slit method and so on. Among them, knife-edge method is quite efficient, easy-to-use and recommended in ISO12233 standard for the wholefrequency MTF curve acquisition. However, the accuracy of the algorithm is affected by Edge Spread Function (ESF) fitting accuracy significantly, which limits the range of application. So in this paper, an optimized knife-edge method using Powell algorithm is proposed to improve the ESF fitting precision. Fermi function model is the most popular ESF fitting model, yet it is vulnerable to the initial values of the parameters. Considering the characteristics of simple and fast convergence, Powell algorithm is applied to fit the accurate parameters adaptively with the insensitivity to the initial parameters. Numerical simulation results reveal the accuracy and robustness of the optimized algorithm under different SNR, edge direction and leaning angles conditions. Experimental results using images of the camera in ZY-3 satellite show that this method is more accurate than the standard knife-edge method of ISO12233 in MTF estimation.

  11. Orbital dependent functionals: An atom projector augmented wave method implementation

    NASA Astrophysics Data System (ADS)

    Xu, Xiao

    This thesis explores the formulation and numerical implementation of orbital dependent exchange-correlation functionals within electronic structure calculations. These orbital-dependent exchange-correlation functionals have recently received renewed attention as a means to improve the physical representation of electron interactions within electronic structure calculations. In particular, electron self-interaction terms can be avoided. In this thesis, an orbital-dependent functional is considered in the context of Hartree-Fock (HF) theory as well as the Optimized Effective Potential (OEP) method and the approximate OEP method developed by Krieger, Li, and Iafrate, known as the KLI approximation. In this thesis, the Fock exchange term is used as a simple well-defined example of an orbital-dependent functional. The Projected Augmented Wave (PAW) method developed by P. E. Blochl has proven to be accurate and efficient for electronic structure calculations for local and semi-local functions because of its accurate evaluation of interaction integrals by controlling multiple moments. We have extended the PAW method to treat orbital-dependent functionals in Hartree-Fock theory and the Optimized Effective Potential method, particularly in the KLI approximation. In the course of study we develop a frozen-core orbital approximation that accurately treats the core electron contributions for above three methods. The main part of the thesis focuses on the treatment of spherical atoms. We have investigated the behavior of PAW-Hartree Fock and PAW-KLI basis, projector, and pseudopotential functions for several elements throughout the periodic table. We have also extended the formalism to the treatment of solids in a plane wave basis and implemented PWPAW-KLI code, which will appear in future publications.

  12. Spatial Statistics for Tumor Cell Counting and Classification

    NASA Astrophysics Data System (ADS)

    Wirjadi, Oliver; Kim, Yoo-Jin; Breuel, Thomas

    To count and classify cells in histological sections is a standard task in histology. One example is the grading of meningiomas, benign tumors of the meninges, which requires to assess the fraction of proliferating cells in an image. As this process is very time consuming when performed manually, automation is required. To address such problems, we propose a novel application of Markov point process methods in computer vision, leading to algorithms for computing the locations of circular objects in images. In contrast to previous algorithms using such spatial statistics methods in image analysis, the present one is fully trainable. This is achieved by combining point process methods with statistical classifiers. Using simulated data, the method proposed in this paper will be shown to be more accurate and more robust to noise than standard image processing methods. On the publicly available SIMCEP benchmark for cell image analysis algorithms, the cell count performance of the present paper is significantly more accurate than results published elsewhere, especially when cells form dense clusters. Furthermore, the proposed system performs as well as a state-of-the-art algorithm for the computer-aided histological grading of meningiomas when combined with a simple k-nearest neighbor classifier for identifying proliferating cells.

  13. An accurate and rapid radiographic method of determining total lung capacity

    PubMed Central

    Reger, R. B.; Young, A.; Morgan, W. K. C.

    1972-01-01

    The accuracy and reliability of Barnhard's radiographic method of determining total lung capacity have been confirmed by several groups of investigators. Despite its simplicity and general reliability, it has several shortcomings, especially when used in large-scale epidemiological surveys. Of these, the most serious is related to film technique; thus, when the cardiac and diaphragmatic shadows are poorly defined, the appropriate measurements cannot be made accurately. A further drawback involves the time needed to measure the segments and to perform the necessary calculations. We therefore set out to develop an abbreviated and simpler radiographic method for determining total lung capacity. This uses a step-wise multiple regression model which allows total lung capacity to be derived as follows: posteroanterior and lateral films are divided into the standard sections as described in the text, the width, depth, and height of sections 1 and 4 are measured in centimetres, finally the necessary derivations and substitutions are made and applied to the formula Ŷ = −1·41148 + (0·00479 X1) + (0·00097 X4), where Ŷ is the total lung capacity. In our hands this method has provided a simple, rapid, and acceptable method of determining total lung capacity. PMID:5034594

  14. Development and application of accurate analytical models for single active electron potentials

    NASA Astrophysics Data System (ADS)

    Miller, Michelle; Jaron-Becker, Agnieszka; Becker, Andreas

    2015-05-01

    The single active electron (SAE) approximation is a theoretical model frequently employed to study scenarios in which inner-shell electrons may productively be treated as frozen spectators to a physical process of interest, and accurate analytical approximations for these potentials are sought as a useful simulation tool. Density function theory is often used to construct a SAE potential, requiring that a further approximation for the exchange correlation functional be enacted. In this study, we employ the Krieger, Li, and Iafrate (KLI) modification to the optimized-effective-potential (OEP) method to reduce the complexity of the problem to the straightforward solution of a system of linear equations through simple arguments regarding the behavior of the exchange-correlation potential in regions where a single orbital dominates. We employ this method for the solution of atomic and molecular potentials, and use the resultant curve to devise a systematic construction for highly accurate and useful analytical approximations for several systems. Supported by the U.S. Department of Energy (Grant No. DE-FG02-09ER16103), and the U.S. National Science Foundation (Graduate Research Fellowship, Grants No. PHY-1125844 and No. PHY-1068706).

  15. Determination of Total Biotin by Liquid Chromatography Coupled with Immunoaffinity Column Cleanup Extraction: Multilaboratory Testing, Final Action 2016.02.

    PubMed

    Joseph, George; Devi, Ranjani; Marley, Elaine C; Leeman, David

    2018-05-01

    Single- and multilaboratory testing data have provided systematic scientific evidence that a simple, selective, accurate, and precise method can be used as a potential candidate reference method for dispute resolution in determining total biotin in all forms of infant, adult, and/or pediatric formula. Using LC coupled with immunoaffinity column cleanup extraction, the method fully meets the intended purpose and applicability statement in AOAC Standard Method Performance Requirement 2014.005. The method was applied to a cross-section of infant formula and adult nutritional matrixes, and acceptable precision and accuracy were established. The analytical platform is inexpensive, and the method can be used in almost any laboratory worldwide with basic facilities. The immunoaffinity column cleanup extraction is the key step to successful analysis.

  16. Simultaneous determination of potassium guaiacolsulfonate, guaifenesin, diphenhydramine HCl and carbetapentane citrate in syrups by using HPLC-DAD coupled with partial least squares multivariate calibration.

    PubMed

    Dönmez, Ozlem Aksu; Aşçi, Bürge; Bozdoğan, Abdürrezzak; Sungur, Sidika

    2011-02-15

    A simple and rapid analytical procedure was proposed for the determination of chromatographic peaks by means of partial least squares multivariate calibration (PLS) of high-performance liquid chromatography with diode array detection (HPLC-DAD). The method is exemplified with analysis of quaternary mixtures of potassium guaiacolsulfonate (PG), guaifenesin (GU), diphenhydramine HCI (DP) and carbetapentane citrate (CP) in syrup preparations. In this method, the area does not need to be directly measured and predictions are more accurate. Though the chromatographic and spectral peaks of the analytes were heavily overlapped and interferents coeluted with the compounds studied, good recoveries of analytes could be obtained with HPLC-DAD coupled with PLS calibration. This method was tested by analyzing the synthetic mixture of PG, GU, DP and CP. As a comparison method, a classsical HPLC method was used. The proposed methods were applied to syrups samples containing four drugs and the obtained results were statistically compared with each other. Finally, the main advantage of HPLC-PLS method over the classical HPLC method tried to emphasized as the using of simple mobile phase, shorter analysis time and no use of internal standard and gradient elution. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Noncontact methods for measuring water-surface elevations and velocities in rivers: Implications for depth and discharge extraction

    USGS Publications Warehouse

    Nelson, Jonathan M.; Kinzel, Paul J.; McDonald, Richard R.; Schmeeckle, Mark

    2016-01-01

    Recently developed optical and videographic methods for measuring water-surface properties in a noninvasive manner hold great promise for extracting river hydraulic and bathymetric information. This paper describes such a technique, concentrating on the method of infrared videog- raphy for measuring surface velocities and both acoustic (laboratory-based) and laser-scanning (field-based) techniques for measuring water-surface elevations. In ideal laboratory situations with simple flows, appropriate spatial and temporal averaging results in accurate water-surface elevations and water-surface velocities. In test cases, this accuracy is sufficient to allow direct inversion of the governing equations of motion to produce estimates of depth and discharge. Unlike other optical techniques for determining local depth that rely on transmissivity of the water column (bathymetric lidar, multi/hyperspectral correlation), this method uses only water-surface information, so even deep and/or turbid flows can be investigated. However, significant errors arise in areas of nonhydrostatic spatial accelerations, such as those associated with flow over bedforms or other relatively steep obstacles. Using laboratory measurements for test cases, the cause of these errors is examined and both a simple semi-empirical method and computational results are presented that can potentially reduce bathymetric inversion errors.

  18. Optical aberration correction for simple lenses via sparse representation

    NASA Astrophysics Data System (ADS)

    Cui, Jinlin; Huang, Wei

    2018-04-01

    Simple lenses with spherical surfaces are lightweight, inexpensive, highly flexible, and can be easily processed. However, they suffer from optical aberrations that lead to limitations in high-quality photography. In this study, we propose a set of computational photography techniques based on sparse signal representation to remove optical aberrations, thereby allowing the recovery of images captured through a single-lens camera. The primary advantage of the proposed method is that many prior point spread functions calibrated at different depths are successfully used for restoring visual images in a short time, which can be generally applied to nonblind deconvolution methods for solving the problem of the excessive processing time caused by the number of point spread functions. The optical software CODE V is applied for examining the reliability of the proposed method by simulation. The simulation results reveal that the suggested method outperforms the traditional methods. Moreover, the performance of a single-lens camera is significantly enhanced both qualitatively and perceptually. Particularly, the prior information obtained by CODE V can be used for processing the real images of a single-lens camera, which provides an alternative approach to conveniently and accurately obtain point spread functions of single-lens cameras.

  19. [Molecular typing methods for Pasteurella multocida-A review].

    PubMed

    Peng, Zhong; Liang, Wan; Wu, Bin

    2016-10-04

    Pasteurella multocida is an important gram-negative pathogenic bacterium that could infect wide ranges of animals. Humans could also be infected by P. multocida via animal bite or scratching. Current typing methods for P. multocida include serological typing methods and molecular typing methods. Of them, serological typing methods are based on immunological assays, which are too complicated for clinical bacteriological studies. However, the molecular methods including multiple PCRs and multilocus sequence typing (MLST) methods are more suitable for bacteriological studies of P. multocida in clinic, with their simple operation, high efficiency and accurate detection compared to the traditional serological typing methods, they are therefore widely used. In the current review, we briefly describe the molecular typing methods for P. multocida. Our aim is to provide a knowledge-foundation for clinical bacteriological investigation especially the molecular investigation for P. multocida.

  20. Accurate and simple method for quantification of hepatic fat content using magnetic resonance imaging: a prospective study in biopsy-proven nonalcoholic fatty liver disease.

    PubMed

    Hatta, Tomoko; Fujinaga, Yasunari; Kadoya, Masumi; Ueda, Hitoshi; Murayama, Hiroaki; Kurozumi, Masahiro; Ueda, Kazuhiko; Komatsu, Michiharu; Nagaya, Tadanobu; Joshita, Satoru; Kodama, Ryo; Tanaka, Eiji; Uehara, Tsuyoshi; Sano, Kenji; Tanaka, Naoki

    2010-12-01

    To assess the degree of hepatic fat content, simple and noninvasive methods with high objectivity and reproducibility are required. Magnetic resonance imaging (MRI) is one such candidate, although its accuracy remains unclear. We aimed to validate an MRI method for quantifying hepatic fat content by calibrating MRI reading with a phantom and comparing MRI measurements in human subjects with estimates of liver fat content in liver biopsy specimens. The MRI method was performed by a combination of MRI calibration using a phantom and double-echo chemical shift gradient-echo sequence (double-echo fast low-angle shot sequence) that has been widely used on a 1.5-T scanner. Liver fat content in patients with nonalcoholic fatty liver disease (NAFLD, n = 26) was derived from a calibration curve generated by scanning the phantom. Liver fat was also estimated by optical image analysis. The correlation between the MRI measurements and liver histology findings was examined prospectively. Magnetic resonance imaging measurements showed a strong correlation with liver fat content estimated from the results of light microscopic examination (correlation coefficient 0.91, P < 0.001) regardless of the degree of hepatic steatosis. Moreover, the severity of lobular inflammation or fibrosis did not influence the MRI measurements. This MRI method is simple and noninvasive, has excellent ability to quantify hepatic fat content even in NAFLD patients with mild steatosis or advanced fibrosis, and can be performed easily without special devices.

  1. A binary method for simple and accurate two-dimensional cursor control from EEG with minimal subject training.

    PubMed

    Kayagil, Turan A; Bai, Ou; Henriquez, Craig S; Lin, Peter; Furlani, Stephen J; Vorbach, Sherry; Hallett, Mark

    2009-05-06

    Brain-computer interfaces (BCI) use electroencephalography (EEG) to interpret user intention and control an output device accordingly. We describe a novel BCI method to use a signal from five EEG channels (comprising one primary channel with four additional channels used to calculate its Laplacian derivation) to provide two-dimensional (2-D) control of a cursor on a computer screen, with simple threshold-based binary classification of band power readings taken over pre-defined time windows during subject hand movement. We tested the paradigm with four healthy subjects, none of whom had prior BCI experience. Each subject played a game wherein he or she attempted to move a cursor to a target within a grid while avoiding a trap. We also present supplementary results including one healthy subject using motor imagery, one primary lateral sclerosis (PLS) patient, and one healthy subject using a single EEG channel without Laplacian derivation. For the four healthy subjects using real hand movement, the system provided accurate cursor control with little or no required user training. The average accuracy of the cursor movement was 86.1% (SD 9.8%), which is significantly better than chance (p = 0.0015). The best subject achieved a control accuracy of 96%, with only one incorrect bit classification out of 47. The supplementary results showed that control can be achieved under the respective experimental conditions, but with reduced accuracy. The binary method provides naïve subjects with real-time control of a cursor in 2-D using dichotomous classification of synchronous EEG band power readings from a small number of channels during hand movement. The primary strengths of our method are simplicity of hardware and software, and high accuracy when used by untrained subjects.

  2. Proton dose distribution measurements using a MOSFET detector with a simple dose-weighted correction method for LET effects.

    PubMed

    Kohno, Ryosuke; Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-04-04

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth-dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high-bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L-shaped bolus. The dose reproducibility, angular dependence and depth-dose response were evaluated using a 190 MeV proton beam. Depth-output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose-weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L-shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors.

  3. Proton dose distribution measurements using a MOSFET detector with a simple dose‐weighted correction method for LET effects

    PubMed Central

    Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-01-01

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth‐dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high‐bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L‐shaped bolus. The dose reproducibility, angular dependence and depth‐dose response were evaluated using a 190 MeV proton beam. Depth‐output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose‐weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L‐shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors. PACS number: 87.56.‐v

  4. Respiratory-phase domain analysis of heart rate variability can accurately estimate cardiac vagal activity during a mental arithmetic task.

    PubMed

    Kotani, Kiyoshi; Takamasu, Kiyoshi; Tachibana, Makoto

    2007-01-01

    The objectives of this paper were to present a method to extract the amplitude of RSA in the respiratory-phase domain, to compare that with subjective or objective indices of the MWL (mental workload), and to compare that with a conventional frequency analysis in terms of its accuracy during a mental arithmetic task. HRV (heart rate variability), ILV (instantaneous lung volume), and motion of the throat were measured under a mental arithmetic experiment and subjective and objective indices were also obtained. The amplitude of RSA was extracted in the respiratory-phase domain, and its correlation with the load level was compared with the results of the frequency domain analysis, which is the standard analysis of the HRV. The subjective and objective indices decreased as the load level increased, showing that the experimental protocol was appropriate. Then, the amplitude of RSA in the respiratory-phase domain also decreased with the increase in the load level. The results of the correlation analysis showed that the respiratory-phase domain analysis has higher negative correlations, -0.84 and -0.82, with the load level as determined by simple correlation and rank correlation, respectively, than does frequency analysis, for which the correlations were found to be -0.54 and -0.63, respectively. In addition, it was demonstrated that the proposed method could be applied to the short-term extraction of RSA amplitude. We proposed a simple and effective method to extract the amplitude of the respiratory sinus arrhythmia (RSA) in the respiratory-phase domain and the results show that this method can estimate cardiac vagal activity more accurately than frequency analysis.

  5. Instillation and Fixation Methods Useful in Mouse Lung Cancer Research.

    PubMed

    Limjunyawong, Nathachit; Mock, Jason; Mitzner, Wayne

    2015-08-31

    The ability to instill live agents, cells, or chemicals directly into the lung without injuring or killing the mice is an important tool in lung cancer research. Although there are a number of methods that have been published showing how to intubate mice for pulmonary function measurements, none are without potential problems for rapid tracheal instillation in large cohorts of mice. In the present paper, a simple and quick method is described that enables an investigator to carry out such instillations in an efficient manner. The method does not require any special tools or lighting and can be learned with very little practice. It involves anesthetizing a mouse, making a small incision in the neck to visualize the trachea, and then inserting an intravenous catheter directly. The small incision is quickly closed with tissue adhesive, and the mice are allowed to recover. A skilled student or technician can do instillations at an average rate of 2 min/mouse. Once the cancer is established, there is frequently a need for quantitative histologic analysis of the lungs. Traditionally pathologists usually do not bother to standardize lung inflation during fixation, and analyses are often based on a scoring system that can be quite subjective. While this may sometime be sufficiently adequate for gross estimates of the size of a lung tumor, any proper stereological quantification of lung structure or cells requires a reproducible fixation procedure and subsequent lung volume measurement. Here we describe simple reliable procedures for both fixing the lungs under pressure and then accurately measuring the fixed lung volume. The only requirement is a laboratory balance that is accurate over a range of 1 mg-300 g. The procedures presented here thus could greatly improve the ability to create, treat, and analyze lung cancers in mice.

  6. [Determination of Total Iron and Fe2+ in Basalt].

    PubMed

    Liu, Jian-xun; Chen, Mei-rong; Jian, Zheng-guo; Wu, Gang; Wu, Zhi-shen

    2015-08-01

    Basalt is the raw material of basalt fiber. The content of FeO and Fe2O3 has a great impact on the properties of basalt fibers. ICP-OES and dichromate method were used to test total Fe and Fe(2+) in basalt. Suitable instrument parameters and analysis lines of Fe were chosen for ICP-OES. The relative standard deviation (RSD) of ICP-OES is 2.2%, and the recovery is in the range of 98%~101%. The method shows simple, rapid and highly accurate for determination of total Fe and Fe(2+) in basalt. The RSD of ICP-OES and dichromate method is 0.42% and 1.4%, respectively.

  7. Simple and sensitive method for quantification of fluorescent enzymatic mature and senescent crosslinks of collagen in bone hydrolysate using single-column high performance liquid chromatography.

    PubMed

    Viguet-Carrin, S; Gineyts, E; Bertholon, C; Delmas, P D

    2009-01-01

    A rapid high performance liquid chromatographic method was developed including an internal standard for the measurement of mature and senescent crosslinks concentration in non-demineralized bone hydrolysates. To avoid the demineralization which is a tedious step, we developed a method based on the use of a solid-phase extraction procedure to clean-up the samples. It resulted in sensitive and accurate measurements: the detection limits as low as 0.2 pmol for the pyridimium crosslinks and 0.02 pmol for the pentosidine. The inter- and intra-assay coefficients of variation were as low as 5% and 2%, respectively, for all crosslinks.

  8. A semi-analytical method for the computation of the Lyapunov exponents of fractional-order systems

    NASA Astrophysics Data System (ADS)

    Caponetto, Riccardo; Fazzino, Stefano

    2013-01-01

    Fractional-order differential equations are interesting for their applications in the construction of mathematical models in finance, materials science or diffusion. In this paper, an application of a well known transformation technique, Differential Transform Method (DTM), to the area of fractional differential equation is employed for calculating Lyapunov exponents of fractional order systems. It is known that the Lyapunov exponents, first introduced by Oseledec, play a crucial role in characterizing the behaviour of dynamical systems. They can be used to analyze the sensitive dependence on initial conditions and the presence of chaotic attractors. The results reveal that the proposed method is very effective and simple and leads to accurate, approximately convergent solutions.

  9. Spectrophotometric estimation of ambroxol and cetirizine hydrochloride from tablet dosage form.

    PubMed

    Gowekar, N M; Pande, V V; Kasture, A V; Tekade, A R; Chandorkar, J G

    2007-07-01

    Fixed dose combination tablets containing ambroxol HCl and cetirizine HCl are clinically used as mucolytic and antiallergic. Several spectrophotometric and HPLC methods have been reported for simultaneous estimation of these drugs with other drugs. The drugs individually and in mixture obeys Beer's law over conc. range 1.2-4.4 microg/mL for cetirizine HCL and for ambroxol HCL 15-52 microg/mL at all five sampling wavelengths (correlation coeff. well above 0.995). The mean recoveries from tablet by standard addition method were 100.18% (+/-2.4) and 100.66 % (+/-2.31). The present work reports simple, accurate and precise spectrophotometric methods for their simultaneous estimation from tablet dosage form.

  10. Method for measuring retardation of infrared wave-plate by modulated-polarized visible light

    NASA Astrophysics Data System (ADS)

    Zhang, Ying; Song, Feijun

    2012-11-01

    A new method for precisely measuring the optical phase retardation of wave-plates in the infrared spectral region is presented by using modulated-polarized visible light. An electro-optic modulator is used to accurately determine the zero point by the frequency-doubled signal of the Modulated-polarized light. A Babinet-Soleil compensator is employed to make the phase delay compensation. Based on this method, an instrument is set up to measure the retardations of the infrared wave-plates with visible region laser. Measurement results with high accuracy and sound repetition are obtained by simple calculation. Its measurement precision is less than and repetitive precision is within 0.3%.

  11. An efficient reliable method to estimate the vaporization enthalpy of pure substances according to the normal boiling temperature and critical properties

    PubMed Central

    Mehmandoust, Babak; Sanjari, Ehsan; Vatani, Mostafa

    2013-01-01

    The heat of vaporization of a pure substance at its normal boiling temperature is a very important property in many chemical processes. In this work, a new empirical method was developed to predict vaporization enthalpy of pure substances. This equation is a function of normal boiling temperature, critical temperature, and critical pressure. The presented model is simple to use and provides an improvement over the existing equations for 452 pure substances in wide boiling range. The results showed that the proposed correlation is more accurate than the literature methods for pure substances in a wide boiling range (20.3–722 K). PMID:25685493

  12. An efficient reliable method to estimate the vaporization enthalpy of pure substances according to the normal boiling temperature and critical properties.

    PubMed

    Mehmandoust, Babak; Sanjari, Ehsan; Vatani, Mostafa

    2014-03-01

    The heat of vaporization of a pure substance at its normal boiling temperature is a very important property in many chemical processes. In this work, a new empirical method was developed to predict vaporization enthalpy of pure substances. This equation is a function of normal boiling temperature, critical temperature, and critical pressure. The presented model is simple to use and provides an improvement over the existing equations for 452 pure substances in wide boiling range. The results showed that the proposed correlation is more accurate than the literature methods for pure substances in a wide boiling range (20.3-722 K).

  13. A Simple and Accurate Method To Calculate Free Energy Profiles and Reaction Rates from Restrained Molecular Simulations of Diffusive Processes.

    PubMed

    Ovchinnikov, Victor; Nam, Kwangho; Karplus, Martin

    2016-08-25

    A method is developed to obtain simultaneously free energy profiles and diffusion constants from restrained molecular simulations in diffusive systems. The method is based on low-order expansions of the free energy and diffusivity as functions of the reaction coordinate. These expansions lead to simple analytical relationships between simulation statistics and model parameters. The method is tested on 1D and 2D model systems; its accuracy is found to be comparable to or better than that of the existing alternatives, which are briefly discussed. An important aspect of the method is that the free energy is constructed by integrating its derivatives, which can be computed without need for overlapping sampling windows. The implementation of the method in any molecular simulation program that supports external umbrella potentials (e.g., CHARMM) requires modification of only a few lines of code. As a demonstration of its applicability to realistic biomolecular systems, the method is applied to model the α-helix ↔ β-sheet transition in a 16-residue peptide in implicit solvent, with the reaction coordinate provided by the string method. Possible modifications of the method are briefly discussed; they include generalization to multidimensional reaction coordinates [in the spirit of the model of Ermak and McCammon (Ermak, D. L.; McCammon, J. A. J. Chem. Phys. 1978, 69, 1352-1360)], a higher-order expansion of the free energy surface, applicability in nonequilibrium systems, and a simple test for Markovianity. In view of the small overhead of the method relative to standard umbrella sampling, we suggest its routine application in the cases where umbrella potential simulations are appropriate.

  14. Direct measurement of clinical mammographic x-ray spectra using a CdTe spectrometer.

    PubMed

    Santos, Josilene C; Tomal, Alessandra; Furquim, Tânia A; Fausto, Agnes M F; Nogueira, Maria S; Costa, Paulo R

    2017-07-01

    To introduce and evaluate a method developed for the direct measurement of mammographic x-ray spectra using a CdTe spectrometer. The assembly of a positioning system and the design of a simple and customized alignment device for this application is described. A positioning system was developed to easily and accurately locate the CdTe detector in the x-ray beam. Additionally, an alignment device to line up the detector with the central axis of the radiation beam was designed. Direct x-ray spectra measurements were performed in two different clinical mammography units and the measured x-ray spectra were compared with computer-generated spectra. In addition, the spectrometer misalignment effect was evaluated by comparing the measured spectra when this device is aligned relatively to when it is misaligned. The positioning and alignment of the spectrometer have allowed the measurements of direct mammographic x-ray spectra in agreement with computer-generated spectra. The most accurate x-ray spectral shape, related with the minimal HVL value, and high photon fluence for measured spectra was found with the spectrometer aligned according to the proposed method. The HVL values derived from both simulated and measured x-ray spectra differ at most 1.3 and 4.5% for two mammography devices evaluated in this study. The experimental method developed in this work allows simple positioning and alignment of a spectrometer for x-ray spectra measurements given the geometrical constraints and maintenance of the original configurations of mammography machines. © 2017 American Association of Physicists in Medicine.

  15. Serum biotin in Japanese children: Enzyme-linked immunosorbent assay measurement.

    PubMed

    Wakabayashi, Kenji; Kodama, Hiroko; Ogawa, Eishin; Sato, Yasuhiro; Motoyama, Kahoko; Suzuki, Mitsuyoshi

    2016-09-01

    Biotin deficiency has been reported in Japanese infants fed special formulas for medical reasons, including those with milk allergy and congenital metabolic diseases, because these formulas contain little biotin. Serum biotin measurement is useful for diagnosing biotin deficiency. We applied a simple and rapid method to analyze serum biotin, and established normal ranges for children and adults. Serum biotin in 188 healthy Japanese children aged 0-4 years and in 25 healthy adults was analyzed using a Biotin ELISA Kit (immundiagnostik). The effects of various conditions on the measurement of serum biotin were also examined. Median biotin in children aged 0-4 years was 10.4 ng/dL (IQR, 7.9-13.4 ng/dL), and that in adults was 12.9 ng/dL (IQR, 10.8-15.8 ng/dL). Normal range was 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults (calculated using two-sided 95%CI). Measurements obtained with this method were not affected by frozen storage, freeze-thaw, or hemolysis, indicating that serum biotin can be analyzed accurately under these conditions, with a possible application to plasma samples. Serum biotin was significantly lower in children than in adults, with the normal range being 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults. This simple and accurate enzyme-linked immunosorbent assay method is useful for diagnosing biotin deficiency. © 2016 The Authors. Pediatrics International published by John Wiley & Sons Australia, Ltd on behalf of Japan Pediatric Society.

  16. Comparison between the basic least squares and the Bayesian approach for elastic constants identification

    NASA Astrophysics Data System (ADS)

    Gogu, C.; Haftka, R.; LeRiche, R.; Molimard, J.; Vautrin, A.; Sankar, B.

    2008-11-01

    The basic formulation of the least squares method, based on the L2 norm of the misfit, is still widely used today for identifying elastic material properties from experimental data. An alternative statistical approach is the Bayesian method. We seek here situations with significant difference between the material properties found by the two methods. For a simple three bar truss example we illustrate three such situations in which the Bayesian approach leads to more accurate results: different magnitude of the measurements, different uncertainty in the measurements and correlation among measurements. When all three effects add up, the Bayesian approach can have a large advantage. We then compared the two methods for identification of elastic constants from plate vibration natural frequencies.

  17. An X-ray diffraction method for semiquantitative mineralogical analysis of Chilean nitrate ore

    USGS Publications Warehouse

    Jackson, J.C.; Ericksent, G.E.

    1997-01-01

    Computer analysis of X-ray diffraction (XRD) data provides a simple method for determining the semiquantitative mineralogical composition of naturally occurring mixtures of saline minerals. The method herein described was adapted from a computer program for the study of mixtures of naturally occurring clay minerals. The program evaluates the relative intensities of selected diagnostic peaks for the minerals in a given mixture, and then calculates the relative concentrations of these minerals. The method requires precise calibration of XRD data for the minerals to be studied and selection of diffraction peaks that minimize inter-compound interferences. The calculated relative abundances are sufficiently accurate for direct comparison with bulk chemical analyses of naturally occurring saline mineral assemblages.

  18. An x-ray diffraction method for semiquantitative mineralogical analysis of chilean nitrate ore

    USGS Publications Warehouse

    John, C.; George, J.; Ericksen, E.

    1997-01-01

    Computer analysis of X-ray diffraction (XRD) data provides a simple method for determining the semiquantitative mineralogical composition of naturally occurring mixtures of saline minerals. The method herein described was adapted from a computer program for the study of mixtures of naturally occurring clay minerals. The program evaluates the relative intensities of selected diagnostic peaks for the minerals in a given mixture, and then calculates the relative concentrations of these minerals. The method requires precise calibration of XRD data for the minerals to be studied and selection of diffraction peaks that minimize inter-compound interferences. The calculated relative abundances are sufficiently accurate for direct comparison with bulk chemical analyses of naturally occurring saline mineral assemblages.

  19. Kinetic determination of propranolol in tablets by oxidation with ceric sulphate.

    PubMed

    Sultan, S M; Altamrah, S A; Aziz Alrahman, A M; Alzamil, I Z; Karrar, M O

    1989-01-01

    A simple and accurate kinetic method for the determination of propranolol has been developed. Cerium(IV) sulphate (0.5 M) is used to oxidize propranolol in 2 M sulphuric acid at room temperature to the ketone form that absorbs light at a lambda max of 525 nm. The fixed-concentration method is used by recording the exact time, t(s), taken for the reaction to reach a fixed absorbance of 0.100. The unknown concentration, c(M), of propranolol is calculated from the equation: l/t = 0 0.000217 + 0.03 c. The method has been applied to the determination of propranolol in proprietary tablets and the results were compared with those obtained by the B.P. and other standard methods.

  20. An approach for automated analysis of particle holograms

    NASA Technical Reports Server (NTRS)

    Stanton, A. C.; Caulfield, H. J.; Stewart, G. W.

    1984-01-01

    A simple method for analyzing droplet holograms is proposed that is readily adaptable to automation using modern image digitizers and analyzers for determination of the number, location, and size distributions of spherical or nearly spherical droplets. The method determines these parameters by finding the spatial location of best focus of the droplet images. With this location known, the particle size may be determined by direct measurement of image area in the focal plane. Particle velocity and trajectory may be determined by comparison of image locations at different instants in time. The method is tested by analyzing digitized images from a reconstructed in-line hologram, and the results show that the method is more accurate than a time-consuming plane-by-plane search for sharpest focus.

  1. Microarray-based cancer prediction using soft computing approach.

    PubMed

    Wang, Xiaosheng; Gotoh, Osamu

    2009-05-26

    One of the difficulties in using gene expression profiles to predict cancer is how to effectively select a few informative genes to construct accurate prediction models from thousands or ten thousands of genes. We screen highly discriminative genes and gene pairs to create simple prediction models involved in single genes or gene pairs on the basis of soft computing approach and rough set theory. Accurate cancerous prediction is obtained when we apply the simple prediction models for four cancerous gene expression datasets: CNS tumor, colon tumor, lung cancer and DLBCL. Some genes closely correlated with the pathogenesis of specific or general cancers are identified. In contrast with other models, our models are simple, effective and robust. Meanwhile, our models are interpretable for they are based on decision rules. Our results demonstrate that very simple models may perform well on cancerous molecular prediction and important gene markers of cancer can be detected if the gene selection approach is chosen reasonably.

  2. Forecasting Air Force Logistics Command Second Destination Transportation: An Application of Multiple Regression Analysis and Neural Networks

    DTIC Science & Technology

    1990-09-01

    without the help from the DSXR staff. William Lyons, Charles Ramsey , and Martin Meeks went above and beyond to help complete this research. Special...develop a valid forecasting model that is significantly more accurate than the one presently used by DSXR and suggested the development and testing of a...method, Strom tested DSXR’s iterative linear regression forecasting technique by examining P1 in the simple regression equation to determine whether

  3. Absolute and angular efficiencies of a microchannel-plate position-sensitive detector

    NASA Technical Reports Server (NTRS)

    Gao, R. S.; Gibner, P. S.; Newman, J. H.; Smith, K. A.; Stebbings, R. F.

    1984-01-01

    This paper presents a characterization of a commercially available position-sensitive detector of energetic ions and neutrals. The detector consists of two microchannel plates followed by a resistive position-encoding anode. The work includes measurement of absolute efficiencies of H(+), He(+), and O(+) ions in the energy range between 250 and 5000 eV, measurement of relative detection efficiencies as a function of particle impact angle, and a simple method for accurate measurement of the time at which a particle strikes the detector.

  4. Blockmodels for connectome analysis

    NASA Astrophysics Data System (ADS)

    Moyer, Daniel; Gutman, Boris; Prasad, Gautam; Faskowitz, Joshua; Ver Steeg, Greg; Thompson, Paul

    2015-12-01

    In the present work we study a family of generative network model and its applications for modeling the human connectome. We introduce a minor but novel variant of the Mixed Membership Stochastic Blockmodel and apply it and two other related model to two human connectome datasets (ADNI and a Bipolar Disorder dataset) with both control and diseased subjects. We further provide a simple generative classifier that, alongside more discriminating methods, provides evidence that blockmodels accurately summarize tractography count networks with respect to a disease classification task.

  5. Ultrasound measurement apparatus for liquids characterization

    NASA Astrophysics Data System (ADS)

    Vieira, R. C.; Costa-Felix, R. P. B.

    2018-03-01

    The present paper discloses the validation of an experimental ultrasound apparatus and method for liquids characterization. The research aims to stablish a simple, reliable, accurate and portable way to identify contaminants in hydrocarbon substances, such as adulteration in gasoline. The results depicted so far demonstrated a general uncertainty of speed of sound assessment less than 10 m s-1, and distance accuracy of less than 1%. Those figures are good enough for an in-site device to evaluate possible contamination of fuels or other liquids.

  6. BPERM version 3.0: A 2-D wakepotential/impedance code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barts, T.; Chou, W.

    1996-10-01

    BPERM 3.0 is an improved version of a previous release. The main purpose of this version is to make it more user friendly. Following a simple 1-2-3 procedure, one obtains both text and graphical output of the wakepotential and impedance for a given geometry. The calculation is based on a boundary perturbation method, which is significantly faster than numerical simulations. It is accurate when the discontinuities are small. In particular, it works well for tapered structures. 5 refs., 3 figs.

  7. A novel simple QSAR model for the prediction of anti-HIV activity using multiple linear regression analysis.

    PubMed

    Afantitis, Antreas; Melagraki, Georgia; Sarimveis, Haralambos; Koutentis, Panayiotis A; Markopoulos, John; Igglessi-Markopoulou, Olga

    2006-08-01

    A quantitative-structure activity relationship was obtained by applying Multiple Linear Regression Analysis to a series of 80 1-[2-hydroxyethoxy-methyl]-6-(phenylthio) thymine (HEPT) derivatives with significant anti-HIV activity. For the selection of the best among 37 different descriptors, the Elimination Selection Stepwise Regression Method (ES-SWR) was utilized. The resulting QSAR model (R (2) (CV) = 0.8160; S (PRESS) = 0.5680) proved to be very accurate both in training and predictive stages.

  8. A moment projection method for population balance dynamics with a shrinkage term

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Shaohua; Yapp, Edward K.Y.; Akroyd, Jethro

    A new method of moments for solving the population balance equation is developed and presented. The moment projection method (MPM) is numerically simple and easy to implement and attempts to address the challenge of particle shrinkage due to processes such as oxidation, evaporation or dissolution. It directly solves the moment transport equation for the moments and tracks the number of the smallest particles using the algorithm by Blumstein and Wheeler (1973) . The performance of the new method is measured against the method of moments (MOM) and the hybrid method of moments (HMOM). The results suggest that MPM performs muchmore » better than MOM and HMOM where shrinkage is dominant. The new method predicts mean quantities which are almost as accurate as a high-precision stochastic method calculated using the established direct simulation algorithm (DSA).« less

  9. Simultaneous determination of some cholesterol-lowering drugs in their binary mixture by novel spectrophotometric methods

    NASA Astrophysics Data System (ADS)

    Lotfy, Hayam Mahmoud; Hegazy, Maha Abdel Monem

    2013-09-01

    Four simple, specific, accurate and precise spectrophotometric methods manipulating ratio spectra were developed and validated for simultaneous determination of simvastatin (SM) and ezetimibe (EZ) namely; extended ratio subtraction (EXRSM), simultaneous ratio subtraction (SRSM), ratio difference (RDSM) and absorption factor (AFM). The proposed spectrophotometric procedures do not require any preliminary separation step. The accuracy, precision and linearity ranges of the proposed methods were determined, and the methods were validated and the specificity was assessed by analyzing synthetic mixtures containing the cited drugs. The four methods were applied for the determination of the cited drugs in tablets and the obtained results were statistically compared with each other and with those of a reported HPLC method. The comparison showed that there is no significant difference between the proposed methods and the reported method regarding both accuracy and precision.

  10. Field Application of the Micro Biological Survey Method for a Simple and Effective Assessment of the Microbiological Quality of Water Sources in Developing Countries

    PubMed Central

    Arienzo, Alyexandra; Sobze, Martin Sanou; Wadoum, Raoul Emeric Guetiya; Losito, Francesca; Colizzi, Vittorio; Antonini, Giovanni

    2015-01-01

    According to the World Health Organization (WHO) guidelines, “safe drinking-water must not represent any significant risk to health over a lifetime of consumption, including different sensitivities that may occur between life stages”. Traditional methods of water analysis are usually complex, time consuming and require an appropriately equipped laboratory, specialized personnel and expensive instrumentation. The aim of this work was to apply an alternative method, the Micro Biological Survey (MBS), to analyse for contaminants in drinking water. Preliminary experiments were carried out to demonstrate the linearity and accuracy of the MBS method and to verify the possibility of using the evaluation of total coliforms in 1 mL of water as a sufficient parameter to roughly though accurately determine water microbiological quality. The MBS method was then tested “on field” to assess the microbiological quality of water sources in the city of Douala (Cameroon, Central Africa). Analyses were performed on both dug and drilled wells in different periods of the year. Results confirm that the MBS method appears to be a valid and accurate method to evaluate the microbiological quality of many water sources and it can be of valuable aid in developing countries. PMID:26308038

  11. Determination of rivaroxaban in patient’s plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS)

    PubMed Central

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels. PMID:28170419

  12. Detection of food intake from swallowing sequences by supervised and unsupervised methods.

    PubMed

    Lopez-Meyer, Paulo; Makeyev, Oleksandr; Schuckers, Stephanie; Melanson, Edward L; Neuman, Michael R; Sazonov, Edward

    2010-08-01

    Studies of food intake and ingestive behavior in free-living conditions most often rely on self-reporting-based methods that can be highly inaccurate. Methods of Monitoring of Ingestive Behavior (MIB) rely on objective measures derived from chewing and swallowing sequences and thus can be used for unbiased study of food intake with free-living conditions. Our previous study demonstrated accurate detection of food intake in simple models relying on observation of both chewing and swallowing. This article investigates methods that achieve comparable accuracy of food intake detection using only the time series of swallows and thus eliminating the need for the chewing sensor. The classification is performed for each individual swallow rather than for previously used time slices and thus will lead to higher accuracy in mass prediction models relying on counts of swallows. Performance of a group model based on a supervised method (SVM) is compared to performance of individual models based on an unsupervised method (K-means) with results indicating better performance of the unsupervised, self-adapting method. Overall, the results demonstrate that highly accurate detection of intake of foods with substantially different physical properties is possible by an unsupervised system that relies on the information provided by the swallowing alone.

  13. Detection of Food Intake from Swallowing Sequences by Supervised and Unsupervised Methods

    PubMed Central

    Lopez-Meyer, Paulo; Makeyev, Oleksandr; Schuckers, Stephanie; Melanson, Edward L.; Neuman, Michael R.; Sazonov, Edward

    2010-01-01

    Studies of food intake and ingestive behavior in free-living conditions most often rely on self-reporting-based methods that can be highly inaccurate. Methods of Monitoring of Ingestive Behavior (MIB) rely on objective measures derived from chewing and swallowing sequences and thus can be used for unbiased study of food intake with free-living conditions. Our previous study demonstrated accurate detection of food intake in simple models relying on observation of both chewing and swallowing. This article investigates methods that achieve comparable accuracy of food intake detection using only the time series of swallows and thus eliminating the need for the chewing sensor. The classification is performed for each individual swallow rather than for previously used time slices and thus will lead to higher accuracy in mass prediction models relying on counts of swallows. Performance of a group model based on a supervised method (SVM) is compared to performance of individual models based on an unsupervised method (K-means) with results indicating better performance of the unsupervised, self-adapting method. Overall, the results demonstrate that highly accurate detection of intake of foods with substantially different physical properties is possible by an unsupervised system that relies on the information provided by the swallowing alone. PMID:20352335

  14. Stirling Analysis Comparison of Commercial vs. High-Order Methods

    NASA Technical Reports Server (NTRS)

    Dyson, Rodger W.; Wilson, Scott D.; Tew, Roy C.; Demko, Rikako

    2007-01-01

    Recently, three-dimensional Stirling engine simulations have been accomplished utilizing commercial Computational Fluid Dynamics software. The validations reported can be somewhat inconclusive due to the lack of precise time accurate experimental results from engines, export control/ proprietary concerns, and the lack of variation in the methods utilized. The last issue may be addressed by solving the same flow problem with alternate methods. In this work, a comprehensive examination of the methods utilized in the commercial codes is compared with more recently developed high-order methods. Specifically, Lele's Compact scheme and Dyson s Ultra Hi-Fi method will be compared with the SIMPLE and PISO methods currently employed in CFD-ACE, FLUENT, CFX, and STAR-CD (all commercial codes which can in theory solve a three-dimensional Stirling model although sliding interfaces and their moving grids limit the effective time accuracy). We will initially look at one-dimensional flows since the current standard practice is to design and optimize Stirling engines with empirically corrected friction and heat transfer coefficients in an overall one-dimensional model. This comparison provides an idea of the range in which commercial CFD software for modeling Stirling engines may be expected to provide accurate results. In addition, this work provides a framework for improving current one-dimensional analysis codes.

  15. Field Application of the Micro Biological Survey Method for a Simple and Effective Assessment of the Microbiological Quality of Water Sources in Developing Countries.

    PubMed

    Arienzo, Alyexandra; Sobze, Martin Sanou; Wadoum, Raoul Emeric Guetiya; Losito, Francesca; Colizzi, Vittorio; Antonini, Giovanni

    2015-08-25

    According to the World Health Organization (WHO) guidelines, "safe drinking-water must not represent any significant risk to health over a lifetime of consumption, including different sensitivities that may occur between life stages". Traditional methods of water analysis are usually complex, time consuming and require an appropriately equipped laboratory, specialized personnel and expensive instrumentation. The aim of this work was to apply an alternative method, the Micro Biological Survey (MBS), to analyse for contaminants in drinking water. Preliminary experiments were carried out to demonstrate the linearity and accuracy of the MBS method and to verify the possibility of using the evaluation of total coliforms in 1 mL of water as a sufficient parameter to roughly though accurately determine water microbiological quality. The MBS method was then tested "on field" to assess the microbiological quality of water sources in the city of Douala (Cameroon, Central Africa). Analyses were performed on both dug and drilled wells in different periods of the year. Results confirm that the MBS method appears to be a valid and accurate method to evaluate the microbiological quality of many water sources and it can be of valuable aid in developing countries.

  16. Stirling Analysis Comparison of Commercial Versus High-Order Methods

    NASA Technical Reports Server (NTRS)

    Dyson, Rodger W.; Wilson, Scott D.; Tew, Roy C.; Demko, Rikako

    2005-01-01

    Recently, three-dimensional Stirling engine simulations have been accomplished utilizing commercial Computational Fluid Dynamics software. The validations reported can be somewhat inconclusive due to the lack of precise time accurate experimental results from engines, export control/proprietary concerns, and the lack of variation in the methods utilized. The last issue may be addressed by solving the same flow problem with alternate methods. In this work, a comprehensive examination of the methods utilized in the commercial codes is compared with more recently developed high-order methods. Specifically, Lele's compact scheme and Dyson's Ultra Hi-Fi method will be compared with the SIMPLE and PISO methods currently employed in CFD-ACE, FLUENT, CFX, and STAR-CD (all commercial codes which can in theory solve a three-dimensional Stirling model with sliding interfaces and their moving grids limit the effective time accuracy). We will initially look at one-dimensional flows since the current standard practice is to design and optimize Stirling engines with empirically corrected friction and heat transfer coefficients in an overall one-dimensional model. This comparison provides an idea of the range in which commercial CFD software for modeling Stirling engines may be expected to provide accurate results. In addition, this work provides a framework for improving current one-dimensional analysis codes.

  17. Extreme Learning Machine and Particle Swarm Optimization in optimizing CNC turning operation

    NASA Astrophysics Data System (ADS)

    Janahiraman, Tiagrajah V.; Ahmad, Nooraziah; Hani Nordin, Farah

    2018-04-01

    The CNC machine is controlled by manipulating cutting parameters that could directly influence the process performance. Many optimization methods has been applied to obtain the optimal cutting parameters for the desired performance function. Nonetheless, the industry still uses the traditional technique to obtain those values. Lack of knowledge on optimization techniques is the main reason for this issue to be prolonged. Therefore, the simple yet easy to implement, Optimal Cutting Parameters Selection System is introduced to help the manufacturer to easily understand and determine the best optimal parameters for their turning operation. This new system consists of two stages which are modelling and optimization. In modelling of input-output and in-process parameters, the hybrid of Extreme Learning Machine and Particle Swarm Optimization is applied. This modelling technique tend to converge faster than other artificial intelligent technique and give accurate result. For the optimization stage, again the Particle Swarm Optimization is used to get the optimal cutting parameters based on the performance function preferred by the manufacturer. Overall, the system can reduce the gap between academic world and the industry by introducing a simple yet easy to implement optimization technique. This novel optimization technique can give accurate result besides being the fastest technique.

  18. Modeling the radiation pattern of LEDs.

    PubMed

    Moreno, Ivan; Sun, Ching-Cherng

    2008-02-04

    Light-emitting diodes (LEDs) come in many varieties and with a wide range of radiation patterns. We propose a general, simple but accurate analytic representation for the radiation pattern of the light emitted from an LED. To accurately render both the angular intensity distribution and the irradiance spatial pattern, a simple phenomenological model takes into account the emitting surfaces (chip, chip array, or phosphor surface), and the light redirected by both the reflecting cup and the encapsulating lens. Mathematically, the pattern is described as the sum of a maximum of two or three Gaussian or cosine-power functions. The resulting equation is widely applicable for any kind of LED of practical interest. We accurately model a wide variety of radiation patterns from several world-class manufacturers.

  19. Principal axis-based correspondence between multiple cameras for people tracking.

    PubMed

    Hu, Weiming; Hu, Min; Zhou, Xue; Tan, Tieniu; Lou, Jianguang; Maybank, Steve

    2006-04-01

    Visual surveillance using multiple cameras has attracted increasing interest in recent years. Correspondence between multiple cameras is one of the most important and basic problems which visual surveillance using multiple cameras brings. In this paper, we propose a simple and robust method, based on principal axes of people, to match people across multiple cameras. The correspondence likelihood reflecting the similarity of pairs of principal axes of people is constructed according to the relationship between "ground-points" of people detected in each camera view and the intersections of principal axes detected in different camera views and transformed to the same view. Our method has the following desirable properties: 1) Camera calibration is not needed. 2) Accurate motion detection and segmentation are less critical due to the robustness of the principal axis-based feature to noise. 3) Based on the fused data derived from correspondence results, positions of people in each camera view can be accurately located even when the people are partially occluded in all views. The experimental results on several real video sequences from outdoor environments have demonstrated the effectiveness, efficiency, and robustness of our method.

  20. Development of a Global Multilayered Cloud Retrieval System

    NASA Technical Reports Server (NTRS)

    Huang, J.; Minnis, P.; Lin, B.; Yi, Y.; Ayers, J. K.; Khaiyer, M. M.; Arduini, R.; Fan, T.-F

    2004-01-01

    A more rigorous multilayered cloud retrieval system has been developed to improve the determination of high cloud properties in multilayered clouds. The MCRS attempts a more realistic interpretation of the radiance field than earlier methods because it explicitly resolves the radiative transfer that would produce the observed radiances. A two-layer cloud model was used to simulate multilayered cloud radiative characteristics. Despite the use of a simplified two-layer cloud reflectance parameterization, the MCRS clearly produced a more accurate retrieval of ice water path than simple differencing techniques used in the past. More satellite data and ground observation have to be used to test the MCRS. The MCRS methods are quite appropriate for interpreting the radiances when the high cloud has a relatively large optical depth (tau(sub I) greater than 2). For thinner ice clouds, a more accurate retrieval might be possible using infrared methods. Selection of an ice cloud retrieval and a variety of other issues must be explored before a complete global application of this technique can be implemented. Nevertheless, the initial results look promising.

  1. Sum-rule corrections: a route to error cancellations in correlation matrix renormalisation theory

    NASA Astrophysics Data System (ADS)

    Liu, C.; Liu, J.; Yao, Y. X.; Wang, C. Z.; Ho, K. M.

    2017-03-01

    We recently proposed the correlation matrix renormalisation (CMR) theory to efficiently and accurately calculate ground state total energy of molecular systems, based on the Gutzwiller variational wavefunction (GWF) to treat the electronic correlation effects. To help reduce numerical complications and better adapt the CMR to infinite lattice systems, we need to further refine the way to minimise the error originated from the approximations in the theory. This conference proceeding reports our recent progress on this key issue, namely, we obtained a simple analytical functional form for the one-electron renormalisation factors, and introduced a novel sum-rule correction for a more accurate description of the intersite electron correlations. Benchmark calculations are performed on a set of molecules to show the reasonable accuracy of the method.

  2. How to achieve more accurate comparisons in organ donation activity: time to effectiveness indicators.

    PubMed

    Deulofeu, R; Bodí, M A; Twose, J; López, P

    2010-06-01

    We are used to comparisons of activity using donation or transplantation population (pmp) rates between regions or countries, without a further evaluation of the process. But crude pmp rates do not clearly reflect real transplantation capacity, because organ procurement does not finish with the donation step; it is also necessary to know the utilization of the obtained organs. The objective of this study was to present methods and indicators deemed necessary to evaluate the effectiveness of the process. We have proposed the use of simple definitions and indicators to more accurately measure and compare the effectiveness of the total organ procurement process. To illustrate the use and performance of these indicators, we have presented the donation and transplantation activity in Catalonia from 2002 to 2007.

  3. Direct reconstruction of dark energy.

    PubMed

    Clarkson, Chris; Zunckel, Caroline

    2010-05-28

    An important issue in cosmology is reconstructing the effective dark energy equation of state directly from observations. With so few physically motivated models, future dark energy studies cannot only be based on constraining a dark energy parameter space. We present a new nonparametric method which can accurately reconstruct a wide variety of dark energy behavior with no prior assumptions about it. It is simple, quick and relatively accurate, and involves no expensive explorations of parameter space. The technique uses principal component analysis and a combination of information criteria to identify real features in the data, and tailors the fitting functions to pick up trends and smooth over noise. We find that we can constrain a large variety of w(z) models to within 10%-20% at redshifts z≲1 using just SNAP-quality data.

  4. A Simple and Accurate Rate-Driven Infiltration Model

    NASA Astrophysics Data System (ADS)

    Cui, G.; Zhu, J.

    2017-12-01

    In this study, we develop a novel Rate-Driven Infiltration Model (RDIMOD) for simulating infiltration into soils. Unlike traditional methods, RDIMOD avoids numerically solving the highly non-linear Richards equation or simply modeling with empirical parameters. RDIMOD employs infiltration rate as model input to simulate one-dimensional infiltration process by solving an ordinary differential equation. The model can simulate the evolutions of wetting front, infiltration rate, and cumulative infiltration on any surface slope including vertical and horizontal directions. Comparing to the results from the Richards equation for both vertical infiltration and horizontal infiltration, RDIMOD simply and accurately predicts infiltration processes for any type of soils and soil hydraulic models without numerical difficulty. Taking into account the accuracy, capability, and computational effectiveness and stability, RDIMOD can be used in large-scale hydrologic and land-atmosphere modeling.

  5. Continuum Modeling of Inductor Hysteresis and Eddy Current Loss Effects in Resonant Circuits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pries, Jason L.; Tang, Lixin; Burress, Timothy A.

    This paper presents experimental validation of a high-fidelity toroid inductor modeling technique. The aim of this research is to accurately model the instantaneous magnetization state and core losses in ferromagnetic materials. Quasi–static hysteresis effects are captured using a Preisach model. Eddy currents are included by coupling the associated quasi-static Everett function to a simple finite element model representing the inductor cross sectional area. The modeling technique is validated against the nonlinear frequency response from two different series RLC resonant circuits using inductors made of electrical steel and soft ferrite. The method is shown to accurately model shifts in resonant frequencymore » and quality factor. The technique also successfully predicts a discontinuity in the frequency response of the ferrite inductor resonant circuit.« less

  6. Design of liver functional reserve monitor based on three-wavelength from IR to NIR.

    PubMed

    Ye, Fuli; Zhan, Huimiao; Shi, Guilian

    2018-05-04

    The preoperative evaluation of liver functional reserve is very important to determine the excision of liver lobe for the patients with liver cancer. There already exist many effective evaluation methods, but these ones have many disadvantages such as large trauma, complicated process and so on. Therefore, it is essential to develop a fast, accurate and simple detection method of liver functional reserve for the practical application in the clinical engineering field. According to the principle of spectrophotometry, this paper proposes a detection method of liver functional reserve based on three-wavelength from infrared light (IR) to near-infrared light (NIR), in which the artery pulse, the vein pulse and the move of tissue are taken into account. By using near-infrared photoelectric sensor technology and excreting experiment of indocyanine green, a minimally invasive, fast and simple testing equipment is designed in this paper. The testing result shows this equipment can greatly reduce the interference from human body and ambient, realize continuous and real-time detection of arterial degree of blood oxygen saturation and liver functional reserve.

  7. Determination of the absorption coefficient of chromophoric dissolved organic matter from underway spectrophotometry.

    PubMed

    Dall'Olmo, Giorgio; Brewin, Robert J W; Nencioli, Francesco; Organelli, Emanuele; Lefering, Ina; McKee, David; Röttgers, Rüdiger; Mitchell, Catherine; Boss, Emmanuel; Bricaud, Annick; Tilstone, Gavin

    2017-11-27

    Measurements of the absorption coefficient of chromophoric dissolved organic matter (ay) are needed to validate existing ocean-color algorithms. In the surface open ocean, these measurements are challenging because of low ay values. Yet, existing global datasets demonstrate that ay could contribute between 30% to 50% of the total absorption budget in the 400-450 nm spectral range, thus making accurate measurement of ay essential to constrain these uncertainties. In this study, we present a simple way of determining ay using a commercially-available in-situ spectrophotometer operated in underway mode. The obtained ay values were validated using independent collocated measurements. The method is simple to implement, can provide measurements with very high spatio-temporal resolution, and has an accuracy of about 0.0004 m -1 and a precision of about 0.0025 m -1 when compared to independent data (at 440 nm). The only limitation for using this method at sea is that it relies on the availability of relatively large volumes of ultrapure water. Despite this limitation, the method can deliver the ay data needed for validating and assessing uncertainties in ocean-colour algorithms.

  8. Simple 1H NMR spectroscopic method for assay of salts of the contrast agent diatrizoate in commercial solutions.

    PubMed

    Hanna, G M; Lau-Cam, C A

    1996-01-01

    A simple, accurate, and specific 1H NMR spectroscopic method was developed for the assay of diatrizoate meglumine or the combination diatrizoate meglumine and diatrizoate sodium in commercial solutions for injection. A mixture of injectable solution and sodium acetate, the internal standard, was diluted with D2O and the 1H NMR spectrum of the solution was obtained. Two approaches were used to calculate the drug content, based on the integral values for the -N-CO-CH3 protons of diatrizoic acid at 2.23 ppm, and -N-CH3 protons of meglumine at 2.73 ppm, and the CH3-CO-protons of sodium acetate at 1.9 ppm. Recoveries (mean +/- standard deviation) of diatrizoic acid and meglumine from 10 synthetic mixtures of various amounts of these compounds with a fixed amount of internal standard were 100.3 +/- 0.55% and 100.1 +/- 0.98%, respectively. In addition to providing a direct means of simultaneously assaying diatrizoic acid and meglumine, the proposed NMR method can also be used to identify diatrizoate meglumine and each of its molecular components.

  9. Determination of the Deacetylation Degree of Chitooligosaccharides

    PubMed Central

    Fu, Chuhan; Wu, Sihui; Liu, Guihua; Guo, Jiao; Su, Zhengquan

    2017-01-01

    The methods for determination of chitosan content recommended in the Chinese Pharmacopoeia and the European Pharmacopoeia are not applicable for evaluation of the extent of deacetylation (deacetylation degree, DD) in chitooligosaccharides (COS). This study explores two different methods for assessment of DD in COS having relatively high and low molecular weights: an acid-base titration with bromocresol green indicator and a first order derivative UV spectrophotometric method for assessment of DD in COS. The accuracy of both methods as a function of molecular weight was also investigated and compared to results obtained using 1H NMR spectroscopy. Our study demonstrates two simple, fast, widely adaptable, highly precise, accurate, and inexpensive methods for the effective determination of DD in COS, which have the potential for widespread commercial applications in developing country. PMID:29068401

  10. Estimation of time averages from irregularly spaced observations - With application to coastal zone color scanner estimates of chlorophyll concentration

    NASA Technical Reports Server (NTRS)

    Chelton, Dudley B.; Schlax, Michael G.

    1991-01-01

    The sampling error of an arbitrary linear estimate of a time-averaged quantity constructed from a time series of irregularly spaced observations at a fixed located is quantified through a formalism. The method is applied to satellite observations of chlorophyll from the coastal zone color scanner. The two specific linear estimates under consideration are the composite average formed from the simple average of all observations within the averaging period and the optimal estimate formed by minimizing the mean squared error of the temporal average based on all the observations in the time series. The resulting suboptimal estimates are shown to be more accurate than composite averages. Suboptimal estimates are also found to be nearly as accurate as optimal estimates using the correct signal and measurement error variances and correlation functions for realistic ranges of these parameters, which makes it a viable practical alternative to the composite average method generally employed at present.

  11. Performance improvement of the one-dot lateral flow immunoassay for aflatoxin B1 by using a smartphone-based reading system.

    PubMed

    Lee, Sangdae; Kim, Giyoung; Moon, Jihea

    2013-04-18

    This study was conducted to develop a simple, rapid, and accurate lateral flow immunoassay (LFIA) detection method for point-of-care diagnosis. The one-dot LFIA for aflatoxin B1 (AFB1) was based on the modified competitive binding format using competition between AFB1 and colloidal gold-AFB1-BSA conjugate for antibody binding sites in the test zone. A Smartphone-based reading system consisting of a Samsung Galaxy S2 Smartphone, a LFIA reader, and a Smartphone application for the image acquisition and data analysis. The detection limit of one-dot LFIA for AFB1 is 5 μg/kg. This method provided semi-quantitative analysis of AFB1 samples in the range of 5 to 1,000 μg/kg. Using combination of the one-dot LFIA and the Smartphone-based reading system, it is possible to conduct a more fast and accurate point-of-care diagnosis.

  12. Performance Improvement of the One-Dot Lateral Flow Immunoassay for Aflatoxin B1 by Using a Smartphone-Based Reading System

    PubMed Central

    Lee, Sangdae; Kim, Giyoung; Moon, Jihea

    2013-01-01

    This study was conducted to develop a simple, rapid, and accurate lateral flow immunoassay (LFIA) detection method for point-of-care diagnosis. The one-dot LFIA for aflatoxin B1 (AFB1) was based on the modified competitive binding format using competition between AFB1 and colloidal gold-AFB1-BSA conjugate for antibody binding sites in the test zone. A Smartphone-based reading system consisting of a Samsung Galaxy S2 Smartphone, a LFIA reader, and a Smartphone application for the image acquisition and data analysis. The detection limit of one-dot LFIA for AFB1 is 5 μg/kg. This method provided semi-quantitative analysis of AFB1 samples in the range of 5 to 1,000 μg/kg. Using combination of the one-dot LFIA and the Smartphone-based reading system, it is possible to conduct a more fast and accurate point-of-care diagnosis. PMID:23598499

  13. Automated discovery and construction of surface phase diagrams using machine learning

    DOE PAGES

    Ulissi, Zachary W.; Singh, Aayush R.; Tsai, Charlie; ...

    2016-08-24

    Surface phase diagrams are necessary for understanding surface chemistry in electrochemical catalysis, where a range of adsorbates and coverages exist at varying applied potentials. These diagrams are typically constructed using intuition, which risks missing complex coverages and configurations at potentials of interest. More accurate cluster expansion methods are often difficult to implement quickly for new surfaces. We adopt a machine learning approach to rectify both issues. Using a Gaussian process regression model, the free energy of all possible adsorbate coverages for surfaces is predicted for a finite number of adsorption sites. Our result demonstrates a rational, simple, and systematic approachmore » for generating accurate free-energy diagrams with reduced computational resources. Finally, the Pourbaix diagram for the IrO 2(110) surface (with nine coverages from fully hydrogenated to fully oxygenated surfaces) is reconstructed using just 20 electronic structure relaxations, compared to approximately 90 using typical search methods. Similar efficiency is demonstrated for the MoS 2 surface.« less

  14. Single-particle cryo-EM-Improved ab initio 3D reconstruction with SIMPLE/PRIME.

    PubMed

    Reboul, Cyril F; Eager, Michael; Elmlund, Dominika; Elmlund, Hans

    2018-01-01

    Cryogenic electron microscopy (cryo-EM) and single-particle analysis now enables the determination of high-resolution structures of macromolecular assemblies that have resisted X-ray crystallography and other approaches. We developed the SIMPLE open-source image-processing suite for analysing cryo-EM images of single-particles. A core component of SIMPLE is the probabilistic PRIME algorithm for identifying clusters of images in 2D and determine relative orientations of single-particle projections in 3D. Here, we extend our previous work on PRIME and introduce new stochastic optimization algorithms that improve the robustness of the approach. Our refined method for identification of homogeneous subsets of images in accurate register substantially improves the resolution of the cluster centers and of the ab initio 3D reconstructions derived from them. We now obtain maps with a resolution better than 10 Å by exclusively processing cluster centers. Excellent parallel code performance on over-the-counter laptops and CPU workstations is demonstrated. © 2017 The Protein Society.

  15. The structure of tropical forests and sphere packings

    PubMed Central

    Jahn, Markus Wilhelm; Dobner, Hans-Jürgen; Wiegand, Thorsten; Huth, Andreas

    2015-01-01

    The search for simple principles underlying the complex architecture of ecological communities such as forests still challenges ecological theorists. We use tree diameter distributions—fundamental for deriving other forest attributes—to describe the structure of tropical forests. Here we argue that tree diameter distributions of natural tropical forests can be explained by stochastic packing of tree crowns representing a forest crown packing system: a method usually used in physics or chemistry. We demonstrate that tree diameter distributions emerge accurately from a surprisingly simple set of principles that include site-specific tree allometries, random placement of trees, competition for space, and mortality. The simple static model also successfully predicted the canopy structure, revealing that most trees in our two studied forests grow up to 30–50 m in height and that the highest packing density of about 60% is reached between the 25- and 40-m height layer. Our approach is an important step toward identifying a minimal set of processes responsible for generating the spatial structure of tropical forests. PMID:26598678

  16. Segmentation by fusion of histogram-based k-means clusters in different color spaces.

    PubMed

    Mignotte, Max

    2008-05-01

    This paper presents a new, simple, and efficient segmentation approach, based on a fusion procedure which aims at combining several segmentation maps associated to simpler partition models in order to finally get a more reliable and accurate segmentation result. The different label fields to be fused in our application are given by the same and simple (K-means based) clustering technique on an input image expressed in different color spaces. Our fusion strategy aims at combining these segmentation maps with a final clustering procedure using as input features, the local histogram of the class labels, previously estimated and associated to each site and for all these initial partitions. This fusion framework remains simple to implement, fast, general enough to be applied to various computer vision applications (e.g., motion detection and segmentation), and has been successfully applied on the Berkeley image database. The experiments herein reported in this paper illustrate the potential of this approach compared to the state-of-the-art segmentation methods recently proposed in the literature.

  17. Simple heuristics in over-the-counter drug choices: a new hint for medical education and practice

    PubMed Central

    Riva, Silvia; Monti, Marco; Antonietti, Alessandro

    2011-01-01

    Introduction Over-the-counter (OTC) drugs are widely available and often purchased by consumers without advice from a health care provider. Many people rely on self-management of medications to treat common medical conditions. Although OTC medications are regulated by the National and the International Health and Drug Administration, many people are unaware of proper dosing, side effects, adverse drug reactions, and possible medication interactions. Purpose This study examined how subjects make their decisions to select an OTC drug, evaluating the role of cognitive heuristics which are simple and adaptive rules that help the decision-making process of people in everyday contexts. Subjects and methods By analyzing 70 subjects’ information-search and decision-making behavior when selecting OTC drugs, we examined the heuristics they applied in order to assess whether simple decision-making processes were also accurate and relevant. Subjects were tested with a sequence of two experimental tests based on a computerized Java system devised to analyze participants’ choices in a virtual environment. Results We found that subjects’ information-search behavior reflected the use of fast and frugal heuristics. In addition, although the heuristics which correctly predicted subjects’ decisions implied significantly fewer cues on average than the subjects did in the information-search task, they were accurate in describing order of information search. A simple combination of a fast and frugal tree and a tallying rule predicted more than 78% of subjects’ decisions. Conclusion The current emphasis in health care is to shift some responsibility onto the consumer through expansion of self medication. To know which cognitive mechanisms are behind the choice of OTC drugs is becoming a relevant purpose of current medical education. These findings have implications both for the validity of simple heuristics describing information searches in the field of OTC drug choices and for current medical education, which has to prepare competent health specialists to orientate and support the choices of their patients. PMID:23745077

  18. Direction Finding Using an Antenna with Direction Dependent Impulse Response

    NASA Technical Reports Server (NTRS)

    Foltz, Heinrich; Kegege, Obadiah

    2016-01-01

    Wideband antennas may be designed to have an impulse response that is direction dependent, not only in amplitude but also in waveform shape. This property can be used to perform direction finding using a single fixed antenna, without the need for an array or antenna rotation. In this paper direction finding is demonstrated using a simple candelabra-shaped monopole operating in the 1-3 GHz range. The method requires a known transmitted pulse shape and high signal-to-noise ratio, and is not as accurate or robust as conventional methods. However, it can add direction finding capability to a wideband communication system without the addition of any hardware.

  19. On estimation of secret message length in LSB steganography in spatial domain

    NASA Astrophysics Data System (ADS)

    Fridrich, Jessica; Goljan, Miroslav

    2004-06-01

    In this paper, we present a new method for estimating the secret message length of bit-streams embedded using the Least Significant Bit embedding (LSB) at random pixel positions. We introduce the concept of a weighted stego image and then formulate the problem of determining the unknown message length as a simple optimization problem. The methodology is further refined to obtain more stable and accurate results for a wide spectrum of natural images. One of the advantages of the new method is its modular structure and a clean mathematical derivation that enables elegant estimator accuracy analysis using statistical image models.

  20. [Determination of protopine and isocorydine in root of Dactylicapnos scandens by HPLC].

    PubMed

    Yan, Tian-qing; Yang, Yan-fang; Ai, Tie-min

    2004-10-01

    To establish a HPLC method for determination of protopine and isocorydine in root of Dactylicapnos scandens. The separation was performed in a PHENOMENEX-C18 column with a mobile phase of methanol-0.2% phosphoric acid (adjusted to pH 7.0 with triethylamine)(50:50), The detection wavelength was at 254 nm and the flow rate was 0.8 mL x min(-1). The average recovery of Protopine and Isocorydine was 97.9%, 98.6% respectively, and RSD 1.3%, 1.4%. This method is accurate, simple and reliable. It can be used for quality control of D. scandens.

  1. A new approach for the determination of sulphur in food samples by high-resolution continuum source flame atomic absorption spectrometer.

    PubMed

    Ozbek, N; Baysal, A

    2015-02-01

    The new approach for the determination of sulphur in foods was developed, and the sulphur concentrations of various fresh and dried food samples determined using a high-resolution continuum source flame atomic absorption spectrometer with an air/acetylene flame. The proposed method was optimised and the validated using standard reference materials, and certified values were found to be within the 95% confidence interval. The sulphur content of foods ranged from less than the LOD to 1.5mgg(-1). The method is accurate, fast, simple and sensitive. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Peak intensity measurement of relativistic lasers via nonlinear Thomson scattering.

    PubMed

    Har-Shemesh, Omri; Di Piazza, Antonino

    2012-04-15

    The measurement of peak laser intensities exceeding 10(20) W/cm(2) is in general a very challenging task. We suggest a simple method to accurately measure such high intensities up to about 10(23) W/cm(2), by colliding a beam of ultrarelativistic electrons with the laser pulse. The method exploits the high directionality of the radiation emitted by ultrarelativistic electrons via nonlinear Thomson scattering. Initial electron energies well within the reach of laser wake-field accelerators are required, allowing in principle for an all-optical setup. Accuracies of the order of 10% are theoretically envisaged. © 2012 Optical Society of America

  3. Principal Effects of Axial Load on Moment-Distribution Analysis of Rigid Structures

    NASA Technical Reports Server (NTRS)

    James, Benjamin Wylie

    1935-01-01

    This thesis presents the method of moment distribution modified to include the effect of axial load upon the bending moments. This modification makes it possible to analyze accurately complex structures, such as rigid fuselage trusses, that heretofore had to be analyzed by approximate formulas and empirical rules. The method is simple enough to be practicable even for complex structures, and it gives a means of analysis for continuous beams that is simpler than the extended three-moment equation now in common use. When the effect of axial load is included, it is found that the basic principles of moment distribution remain unchanged, the only difference being that the factors used, instead of being constants for a given member, become functions of the axial load. Formulas have been developed for these factors, and curves plotted so that their applications requires no more work than moment distribution without axial load. Simple problems have been included to illustrate the use of the curves.

  4. Development of a simple and low-cost enzymatic methodology for quantitative analysis of carbamates in meat samples of forensic interest.

    PubMed

    Sabino, Bruno Duarte; Torraca, Tathiana Guilliod; Moura, Claudia Melo; Rozenbaum, Hannah Felicia; de Castro Faria, Mauro Velho

    2010-05-01

    Foods contaminated with a granulated material similar to Temik (a commercial pesticide formulation containing the carbamate insecticide aldicarb) are often involved in accidental ingestion, suicides, and homicides in Brazil. We developed a simple technique to detect aldicarb. This technique is based on the inhibition of a stable preparation of the enzyme acetylcholinesterase, and it is specially adapted for forensic purposes. It comprises an initial extraction step with the solvent methylene chloride followed by a colorimetric acetylcholinesterase assay. We propose that results of testing contaminated forensic samples be expressed in aldicarb equivalents because, even though all other carbamates are also potent enzyme inhibitors, aldicarb is the contaminant most frequently found in forensic samples. This method is rapid (several samples can be run in a period of 2 h) and low cost. This method also proved to be precise and accurate, detecting concentrations as low as 40 microg/kg of aldicarb in meat samples.

  5. Effects of practice on the Wechsler Adult Intelligence Scale-IV across 3- and 6-month intervals.

    PubMed

    Estevis, Eduardo; Basso, Michael R; Combs, Dennis

    2012-01-01

    A total of 54 participants (age M = 20.9; education M = 14.9; initial Full Scale IQ M = 111.6) were administered the Wechsler Adult Intelligence Scale-Fourth Edition (WAIS-IV) at baseline and again either 3 or 6 months later. Scores on the Full Scale IQ, Verbal Comprehension, Working Memory, Perceptual Reasoning, Processing Speed, and General Ability Indices improved approximately 7, 5, 4, 5, 9, and 6 points, respectively, and increases were similar regardless of whether the re-examination occurred over 3- or 6-month intervals. Reliable change indices (RCI) were computed using the simple difference and bivariate regression methods, providing estimated base rates of change across time. The regression method provided more accurate estimates of reliable change than did the simple difference between baseline and follow-up scores. These findings suggest that prior exposure to the WAIS-IV results in significant score increments. These gains reflect practice effects instead of genuine intellectual changes, which may lead to errors in clinical judgment.

  6. High density lipoproteins: Measurement techniques and potential biomarkers of cardiovascular risk

    PubMed Central

    Hafiane, Anouar; Genest, Jacques

    2015-01-01

    Plasma high density lipoprotein cholesterol (HDL) comprises a heterogeneous family of lipoprotein species, differing in surface charge, size and lipid and protein compositions. While HDL cholesterol (C) mass is a strong, graded and coherent biomarker of cardiovascular risk, genetic and clinical trial data suggest that the simple measurement of HDL-C may not be causal in preventing atherosclerosis nor reflect HDL functionality. Indeed, the measurement of HDL-C may be a biomarker of cardiovascular health. To assess the issue of HDL function as a potential therapeutic target, robust and simple analytical methods are required. The complex pleiotropic effects of HDL make the development of a single measurement challenging. Development of laboratory assays that accurately HDL function must be developed validated and brought to high-throughput for clinical purposes. This review discusses the limitations of current laboratory technologies for methods that separate and quantify HDL and potential application to predict CVD, with an emphasis on emergent approaches as potential biomarkers in clinical practice. PMID:26674734

  7. Microstrip Ring Resonator for Soil Moisture Measurements

    NASA Technical Reports Server (NTRS)

    Sarabandi, Kamal; Li, Eric S.

    1993-01-01

    Accurate determination of spatial soil moisture distribution and monitoring its temporal variation have a significant impact on the outcomes of hydrologic, ecologic, and climatic models. Development of a successful remote sensing instrument for soil moisture relies on the accurate knowledge of the soil dielectric constant (epsilon(sub soil)) to its moisture content. Two existing methods for measurement of dielectric constant of soil at low and high frequencies are, respectively, the time domain reflectometry and the reflection coefficient measurement using an open-ended coaxial probe. The major shortcoming of these methods is the lack of accurate determination of the imaginary part of epsilon(sub soil). In this paper a microstrip ring resonator is proposed for the accurate measurement of soil dielectric constant. In this technique the microstrip ring resonator is placed in contact with soil medium and the real and imaginary parts of epsilon(sub soil) are determined from the changes in the resonant frequency and the quality factor of the resonator respectively. The solution of the electromagnetic problem is obtained using a hybrid approach based on the method of moments solution of the quasi-static formulation in conjunction with experimental data obtained from reference dielectric samples. Also a simple inversion algorithm for epsilon(sub soil) = epsilon'(sub r) + j(epsilon"(sub r)) based on regression analysis is obtained. It is shown that the wide dynamic range of the measured quantities provides excellent accuracy in the dielectric constant measurement. A prototype microstrip ring resonator at L-band is designed and measurements of soil with different moisture contents are presented and compared with other approaches.

  8. Analytical Method Development and Validation for the Simultaneous Estimation of Abacavir and Lamivudine by Reversed-phase High-performance Liquid Chromatography in Bulk and Tablet Dosage Forms.

    PubMed

    Raees Ahmad, Sufiyan Ahmad; Patil, Lalit; Mohammed Usman, Mohammed Rageeb; Imran, Mohammad; Akhtar, Rashid

    2018-01-01

    A simple rapid, accurate, precise, and reproducible validated reverse phase high performance liquid chromatography (HPLC) method was developed for the determination of Abacavir (ABAC) and Lamivudine (LAMI) in bulk and tablet dosage forms. The quantification was carried out using Symmetry Premsil C18 (250 mm × 4.6 mm, 5 μm) column run in isocratic way using mobile phase comprising methanol: water (0.05% orthophosphoric acid with pH 3) 83:17 v/v and a detection wavelength of 245 nm and injection volume of 20 μl, with a flow rate of 1 ml/min. In the developed method, the retention times of ABAC and LAMI were found to be 3.5 min and 7.4 min, respectively. The method was validated in terms of linearity, precision, accuracy, limits of detection, limits of quantitation, and robustness in accordance with the International Conference on Harmonization guidelines. The assay of the proposed method was found to be 99% - 101%. The recovery studies were also carried out and mean % recovery was found to be 99% - 101%. The % relative standard deviation from reproducibility was found to be <2%. The proposed method was statistically evaluated and can be applied for routine quality control analysis of ABAC and LAMI in bulk and in tablet dosage form. Attempts were made to develop RP-HPLC method for simultaneous estimation of Abacavir and Lamivudine for the RP-HPLC method. The developed method was validated according to the ICH guidelines. The linearity, precision, range, robustness were within the limits as specified by the ICH guidelines. Hence the method was found to be simple, accurate, precise, economic and reproducible. So the proposed methods can be used for the routine quality control analysis of Abacavir and Lamivudine in bulk drug as well as in formulations. Abbreviations Used: HPLC: High-performance liquid chromatography, UV: Ultraviolet, ICH: International Conference on Harmonization, ABAC: Abacavir, LAMI: Lamivudine, HIV: Human immunodeficiency virus, AIDS: Acquired immunodeficiency syndrome, NRTI: Nucleoside reverse transcriptase inhibitors, ARV: Antiretroviral, RSD: Relative standard deviation, RT: Retention time, SD: Standard deviation.

  9. The single water-surface sweep estimation method accurately estimates very low (n = 4) to low-moderate (n = 25-100) and high (n > 100) Aedes aegypti (Diptera: Culicidae) pupae numbers in large water containers up to 13 times faster than the exhaustive sweep and total count method and without any sediment contamination.

    PubMed

    Romero-Vivas, C M; Llinás, H; Falconar, A K

    2015-03-01

    To confirm that a single water-surface sweep-net collection coupled with three calibration factors (2.6, 3.0 and 3.5 for 1/3, 2/3 and 3/3 water levels, respectively) (WSCF) could accurately estimate very low to high Aedes aegypti pupae numbers in water containers more rapidly than the exhaustive 5-sweep and total count (ESTC) method recommended by WHO. Both methods were compared in semi-field trials using low (n = 25) to moderate (n = 50-100) pupae numbers in a 250-l drum at 1/3, 2/3 and 3/3 water levels, and by their mean-time determinations using 200 pupae in three 220- to 1024-l water containers at these water levels. Accuracy was further assessed using 69.1% (393/569) of the field-based drums and tanks which contained <100 pupae. The WSCF method accurately estimated total populations in the semi-field trials up to 13.0 times faster than the ESTC method (all P < 0.001); no significant differences (all P-values ≥ 0.05) were obtained between the methods for very low (n = 4) to low-moderate (n = 25-100) and high (n > 100) pupae numbers/container and without sediment disturbance. The simple WSCF method sensitively, accurately and robustly estimated total pupae numbers in their principal breeding sites worldwide, containers with >20 l water volumes, significantly (2.7- to 13.0-fold: all P-values <0.001) faster than the ESTC method for very low to high pupae numbers/container without contaminating the clean water by sediment disturbance which is generated using the WHO-recommended ESTC method. The WSCF method seems ideal for global community-based surveillance and control programmes. © 2014 John Wiley & Sons Ltd.

  10. Digital frequency-offset detector

    NASA Technical Reports Server (NTRS)

    Bogart, R. W.; Juengst, M. J.

    1977-01-01

    Simple, low-cost device with designer-selectable tolerances provides accurate frequency comparison with minimal circuitry and ease of adjustment. Warning alerts if frequencies being compared fall outside selected tolerance. Device can be applied to any electronic system where accurate timing or frequency control is important.

  11. A simple method to predict body temperature of small reptiles from environmental temperature.

    PubMed

    Vickers, Mathew; Schwarzkopf, Lin

    2016-05-01

    To study behavioral thermoregulation, it is useful to use thermal sensors and physical models to collect environmental temperatures that are used to predict organism body temperature. Many techniques involve expensive or numerous types of sensors (cast copper models, or temperature, humidity, radiation, and wind speed sensors) to collect the microhabitat data necessary to predict body temperatures. Expense and diversity of requisite sensors can limit sampling resolution and accessibility of these methods. We compare body temperature predictions of small lizards from iButtons, DS18B20 sensors, and simple copper models, in both laboratory and natural conditions. Our aim was to develop an inexpensive yet accurate method for body temperature prediction. Either method was applicable given appropriate parameterization of the heat transfer equation used. The simplest and cheapest method was DS18B20 sensors attached to a small recording computer. There was little if any deficit in precision or accuracy compared to other published methods. We show how the heat transfer equation can be parameterized, and it can also be used to predict body temperature from historically collected data, allowing strong comparisons between current and previous environmental temperatures using the most modern techniques. Our simple method uses very cheap sensors and loggers to extensively sample habitat temperature, improving our understanding of microhabitat structure and thermal variability with respect to small ectotherms. While our method was quite precise, we feel any potential loss in accuracy is offset by the increase in sample resolution, important as it is increasingly apparent that, particularly for small ectotherms, habitat thermal heterogeneity is the strongest influence on transient body temperature.

  12. Fast and accurate preparation fatty acid methyl esters by microwave-assisted derivatization in the yeast Saccharomyces cerevisiae.

    PubMed

    Khoomrung, Sakda; Chumnanpuen, Pramote; Jansa-ard, Suwanee; Nookaew, Intawat; Nielsen, Jens

    2012-06-01

    We present a fast and accurate method for preparation of fatty acid methyl esters (FAMEs) using microwave-assisted derivatization of fatty acids present in yeast samples. The esterification of free/bound fatty acids to FAMEs was completed within 5 min, which is 24 times faster than with conventional heating methods. The developed method was validated in two ways: (1) through comparison with a conventional method (hot plate) and (2) through validation with the standard reference material (SRM) 3275-2 omega-3 and omega-6 fatty acids in fish oil (from the Nation Institute of Standards and Technology, USA). There were no significant differences (P>0.05) in yields of FAMEs with both validations. By performing a simple modification of closed-vessel microwave heating, it was possible to carry out the esterification in Pyrex glass tubes kept inside the closed vessel. Hereby, we are able to increase the number of sample preparations to several hundred samples per day as the time for preparation of reused vessels was eliminated. Pretreated cell disruption steps are not required, since the direct FAME preparation provides equally quantitative results. The new microwave-assisted derivatization method facilitates the preparation of FAMEs directly from yeast cells, but the method is likely to also be applicable for other biological samples.

  13. A new method to address verification bias in studies of clinical screening tests: cervical cancer screening assays as an example.

    PubMed

    Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D

    2014-03-01

    Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Robust and Accurate Shock Capturing Method for High-Order Discontinuous Galerkin Methods

    NASA Technical Reports Server (NTRS)

    Atkins, Harold L.; Pampell, Alyssa

    2011-01-01

    A simple yet robust and accurate approach for capturing shock waves using a high-order discontinuous Galerkin (DG) method is presented. The method uses the physical viscous terms of the Navier-Stokes equations as suggested by others; however, the proposed formulation of the numerical viscosity is continuous and compact by construction, and does not require the solution of an auxiliary diffusion equation. This work also presents two analyses that guided the formulation of the numerical viscosity and certain aspects of the DG implementation. A local eigenvalue analysis of the DG discretization applied to a shock containing element is used to evaluate the robustness of several Riemann flux functions, and to evaluate algorithm choices that exist within the underlying DG discretization. A second analysis examines exact solutions to the DG discretization in a shock containing element, and identifies a "model" instability that will inevitably arise when solving the Euler equations using the DG method. This analysis identifies the minimum viscosity required for stability. The shock capturing method is demonstrated for high-speed flow over an inviscid cylinder and for an unsteady disturbance in a hypersonic boundary layer. Numerical tests are presented that evaluate several aspects of the shock detection terms. The sensitivity of the results to model parameters is examined with grid and order refinement studies.

  15. Simultaneous Quantification of Multiple Alternatively Spliced mRNA Transcripts Using Droplet Digital PCR.

    PubMed

    Sun, Bing; Zheng, Yun-Ling

    2018-01-01

    Currently there is no sensitive, precise, and reproducible method to quantitate alternative splicing of mRNA transcripts. Droplet digital™ PCR (ddPCR™) analysis allows for accurate digital counting for quantification of gene expression. Human telomerase reverse transcriptase (hTERT) is one of the essential components required for telomerase activity and for the maintenance of telomeres. Several alternatively spliced forms of hTERT mRNA in human primary and tumor cells have been reported in the literature. Using one pair of primers and two probes for hTERT, four alternatively spliced forms of hTERT (α-/β+, α+/β- single deletions, α-/β- double deletion, and nondeletion α+/β+) were accurately quantified through a novel analysis method via data collected from a single ddPCR reaction. In this chapter, we describe this ddPCR method that enables direct quantitative comparison of four alternatively spliced forms of the hTERT messenger RNA without the need for internal standards or multiple pairs of primers specific for each variant, eliminating the technical variation due to differential PCR amplification efficiency for different amplicons and the challenges of quantification using standard curves. This simple and straightforward method should have general utility for quantifying alternatively spliced gene transcripts.

  16. Digital Signal Processing Methods for Ultrasonic Echoes.

    PubMed

    Sinding, Kyle; Drapaca, Corina; Tittmann, Bernhard

    2016-04-28

    Digital signal processing has become an important component of data analysis needed in industrial applications. In particular, for ultrasonic thickness measurements the signal to noise ratio plays a major role in the accurate calculation of the arrival time. For this application a band pass filter is not sufficient since the noise level cannot be significantly decreased such that a reliable thickness measurement can be performed. This paper demonstrates the abilities of two regularization methods - total variation and Tikhonov - to filter acoustic and ultrasonic signals. Both of these methods are compared to a frequency based filtering for digitally produced signals as well as signals produced by ultrasonic transducers. This paper demonstrates the ability of the total variation and Tikhonov filters to accurately recover signals from noisy acoustic signals faster than a band pass filter. Furthermore, the total variation filter has been shown to reduce the noise of a signal significantly for signals with clear ultrasonic echoes. Signal to noise ratios have been increased over 400% by using a simple parameter optimization. While frequency based filtering is efficient for specific applications, this paper shows that the reduction of noise in ultrasonic systems can be much more efficient with regularization methods.

  17. A phasing and imputation method for pedigreed populations that results in a single-stage genomic evaluation

    PubMed Central

    2012-01-01

    Background Efficient, robust, and accurate genotype imputation algorithms make large-scale application of genomic selection cost effective. An algorithm that imputes alleles or allele probabilities for all animals in the pedigree and for all genotyped single nucleotide polymorphisms (SNP) provides a framework to combine all pedigree, genomic, and phenotypic information into a single-stage genomic evaluation. Methods An algorithm was developed for imputation of genotypes in pedigreed populations that allows imputation for completely ungenotyped animals and for low-density genotyped animals, accommodates a wide variety of pedigree structures for genotyped animals, imputes unmapped SNP, and works for large datasets. The method involves simple phasing rules, long-range phasing and haplotype library imputation and segregation analysis. Results Imputation accuracy was high and computational cost was feasible for datasets with pedigrees of up to 25 000 animals. The resulting single-stage genomic evaluation increased the accuracy of estimated genomic breeding values compared to a scenario in which phenotypes on relatives that were not genotyped were ignored. Conclusions The developed imputation algorithm and software and the resulting single-stage genomic evaluation method provide powerful new ways to exploit imputation and to obtain more accurate genetic evaluations. PMID:22462519

  18. Indirect spectrophotometric determination of arbutin, whitening agent through oxidation by periodate and complexation with ferric chloride

    NASA Astrophysics Data System (ADS)

    Barsoom, B. N.; Abdelsamad, A. M. E.; Adib, N. M.

    2006-07-01

    A simple and accurate spectrophotometric method for the determination of arbutin (glycosylated hydroquinone) is described. It is based on the oxidation of arbutin by periodate in presence of iodate. Excess periodate causes liberation of iodine at pH 8.0. The unreacted periodate is determined by measurement of the liberated iodine spectrophotometrically in the wavelength range (300-500 nm). A calibration curve was constructed for more accurate results and the correlation coefficient of linear regression analysis was -0.9778. The precision of this method was better than 6.17% R.S.D. ( n = 3). Regression analysis of Bear-Lambert plot shows good correlation in the concentration range 25-125 ug/ml. The identification limit was determined to be 25 ug/ml a detailed study of the reaction conditions was carried out, including effect of changing pH, time, temperature and volume of periodate. Analyzing pure and authentic samples containing arbutin tested the validity of the proposed method which has an average percent recovery of 100.86%. An alternative method is also proposed which involves a complexation reaction between arbutin and ferric chloride solution. The produced complex which is yellowish-green in color was determined spectophotometrically.

  19. Smart fast blood counting of trace volumes of body fluids from various mammalian species using a compact custom-built microscope cytometer (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian

    2016-03-01

    Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.

  20. Colorimetric microdetermination of captopril in pure form and in pharmaceutical formulations

    NASA Astrophysics Data System (ADS)

    Shama, Sayed Ahmed; El-Sayed Amin, Alla; Omara, Hany

    2006-11-01

    A simple, rapid, accurate, precise and sensitive colorimetric method for the determination of captopril (CAP) in bulk sample and in dosage forms is described. The method is based on oxidation of the drug by potassium permanganate in acidic medium and determination of the unreacted oxidant by measuring the decrease in absorbance for five different dyes; methylene blue (MB); acid blue 74 (AB), acid red 73 (AR), amaranth dye (AM) and acid orange 7 (AO) at a suitable λmax (660, 610, 510, 520, and 485 nm), respectively. Regression analysis of Beer's plots showed good correlation in the concentration ranges (0.4 12.5, 0.3 10, 0.5 11, 0.4 8.3 and 0.5 9.3 μg ml-1), respectively. The apparent molar absorbtivity, Sandell sensitivity, detection and quantitation limits were calculated. For more accurate results, Ringbom optimum concentration ranges were 0.5 12, 0.5 9.6, 0.6 10.5, 0.5 8.0 and 0.7 9.0 μg ml-1, respectively. The validity of the proposed method was tested by analyzing in pure and dosage forms containing CAP whether alone or in combination with hydrochlorothiazide. Statistical analysis of the results reflects that the proposed procedures are precise, accurate and easily applicable for the determination of CAP in pure form and in pharmaceutical preparations. Also, the stability constant was determined and the free energy change was calculated potentiometrically.

  1. A validated LC method for determination of 2,3-dichlorobenzoic acid and its associated regio isomers.

    PubMed

    Krishnaiah, Ch; Sri, Khagga Bhavya

    2012-05-01

    A simple, selective and sensitive gradient reversed-phase liquid chromatography method has been developed for the separation and determination of 2,3-dichlorobenzoic acid, which is an intermediate of the lamotrizine drug substance, and its regio isomers. The separation was achieved on a reversed-phase United States Pharmacopeia L1 (C-18) column using 0.01 M ammonium acetate buffer at pH 2.5 and methanol (50:50 v/v) mixture as mobile phase A and a methanol and water mixture (80:20 v/v) as mobile phase B in a gradient elution at flow rate 1.2 mL/min with ultraviolet detection at 210 nm. The method is found to be selective, precise, linear, accurate and robust. It was used for quality assurance and monitoring the synthetic reactions involved in the process development of lamotrizine. The method is found to be simple, rapid, specific and reliable for the determination of unreacted levels of raw materials and isomers in reaction mixtures and finished product lamotrizine. The method was fully validated as per International Conference of Harmonization guidelines and results from validation confirm that the method is highly suitable for its intended purpose. © The Author [2012]. Published by Oxford University Press. All rights reserved.

  2. Simple and fast PO-CL method for the evaluation of antioxidant capacity of hydrophilic and hydrophobic antioxidants.

    PubMed

    Zargoosh, Kiomars; Ghayeb, Yousef; Azmoon, Behnaz; Qandalee, Mohammad

    2013-08-01

    A simple and fast procedure is described for evaluating the antioxidant activity of hydrophilic and hydrophobic compounds by using the peroxyoxalate-chemiluminescence (PO-CL) reaction of Bis(2,4,6-trichlorophenyl) oxalate (TCPO) with hydrogen peroxide in the presence of di(tert-butyl)2-(tert-butylamino)-5-[(E)-2-phenyl-1-ethenyl]3,4-furandicarboxylate as a highly fluorescent fluorophore. The IC50 values of the well-known antioxidants were calculated and the results were expressed as gallic equivalent antioxidant capacity (GEAC). It was found that the proposed method is free of physical quenching and oxidant interference, for this reason, proposed method is able to determine the accurate scavenging activity of the antioxidants to the free radicals. Finally, the proposed method was applied to the evaluation of antioxidant activity of complex real samples such as soybean oil and sunflower oil (as hydrophobic samples) and honey (as hydrophilic sample). To the best of our knowledge, this is the first time that total antioxidant activity can be determined directly in soybean oil, sunflower oil and honey (not in their extracts) using PO-CL reactions. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. A simple method for finding explicit analytic transition densities of diffusion processes with general diploid selection.

    PubMed

    Song, Yun S; Steinrücken, Matthias

    2012-03-01

    The transition density function of the Wright-Fisher diffusion describes the evolution of population-wide allele frequencies over time. This function has important practical applications in population genetics, but finding an explicit formula under a general diploid selection model has remained a difficult open problem. In this article, we develop a new computational method to tackle this classic problem. Specifically, our method explicitly finds the eigenvalues and eigenfunctions of the diffusion generator associated with the Wright-Fisher diffusion with recurrent mutation and arbitrary diploid selection, thus allowing one to obtain an accurate spectral representation of the transition density function. Simplicity is one of the appealing features of our approach. Although our derivation involves somewhat advanced mathematical concepts, the resulting algorithm is quite simple and efficient, only involving standard linear algebra. Furthermore, unlike previous approaches based on perturbation, which is applicable only when the population-scaled selection coefficient is small, our method is nonperturbative and is valid for a broad range of parameter values. As a by-product of our work, we obtain the rate of convergence to the stationary distribution under mutation-selection balance.

  4. A Simple Method for Finding Explicit Analytic Transition Densities of Diffusion Processes with General Diploid Selection

    PubMed Central

    Song, Yun S.; Steinrücken, Matthias

    2012-01-01

    The transition density function of the Wright–Fisher diffusion describes the evolution of population-wide allele frequencies over time. This function has important practical applications in population genetics, but finding an explicit formula under a general diploid selection model has remained a difficult open problem. In this article, we develop a new computational method to tackle this classic problem. Specifically, our method explicitly finds the eigenvalues and eigenfunctions of the diffusion generator associated with the Wright–Fisher diffusion with recurrent mutation and arbitrary diploid selection, thus allowing one to obtain an accurate spectral representation of the transition density function. Simplicity is one of the appealing features of our approach. Although our derivation involves somewhat advanced mathematical concepts, the resulting algorithm is quite simple and efficient, only involving standard linear algebra. Furthermore, unlike previous approaches based on perturbation, which is applicable only when the population-scaled selection coefficient is small, our method is nonperturbative and is valid for a broad range of parameter values. As a by-product of our work, we obtain the rate of convergence to the stationary distribution under mutation–selection balance. PMID:22209899

  5. The Development and Validation of Novel, Simple High-Performance Liquid Chromatographic Method with Refractive Index Detector for Quantification of Memantine Hydrochloride in Dissolution Samples.

    PubMed

    Sawant, Tukaram B; Wakchaure, Vikas S; Rakibe, Udyakumar K; Musmade, Prashant B; Chaudhari, Bhata R; Mane, Dhananjay V

    2017-07-01

    The present study was aimed to develop an analytical method for quantification of memantine (MEM) hydrochloride in dissolution samples using high-performance liquid chromatography with refractive index (RI) detector. The chromatographic separation was achieved on C18 (250 × 4.5 mm, 5 μm) column using isocratic mobile phase comprises of buffer (pH 5.2):methanol (40:60 v/v) pumped at a flow rate of 1.0 mL/min. The column effluents were monitored using RI detector. The retention time of MEM was found to be ~6.5 ± 0.3 min. The developed chromatographic method was validated and found to be linear over the concentration range of 5.0-45.0 μg/mL for MEM. Mean recovery of MEM was found to be 99.2 ± 0.5% (w/w). The method was found to be simple, fast, precise and accurate, which can be utilized for the quantification of MEM in dissolution samples. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Determining gestational age and preterm birth in rural Guatemala: A comparison of methods.

    PubMed

    Weinstein, John R; Thompson, Lisa M; Díaz Artiga, Anaité; Bryan, Joe P; Arriaga, William E; Omer, Saad B; McCracken, John P

    2018-01-01

    Preterm birth is the leading cause of death among children <5 years of age. Accurate determination of prematurity is necessary to provide appropriate neonatal care and guide preventive measures. To estimate the most accurate method to identify infants at risk for adverse outcomes, we assessed the validity of two widely available methods-last menstrual period (LMP) and the New Ballard (NB) neonatal assessment-against ultrasound in determining gestational age and preterm birth in highland Guatemala. Pregnant women (n = 188) were recruited with a gestational age <20 weeks and followed until delivery. Ultrasound was performed by trained physicians and LMP was collected during recruitment. NB was performed on infants within 96 hours of birth by trained study nurses. LMP and NB accuracy at determining gestational age and identifying prematurity was assessed by comparing them to ultrasound. By ultrasound, infant mean gestational age at birth was 38.3 weeks (SD = 1.6) with 16% born at less than 37 gestation. LMP was more accurate than NB (mean difference of +0.13 weeks for LMP and +0.61 weeks for NB). However, LMP and NB estimates had low agreement with ultrasound-determined gestational age (Lin's concordance<0.48 for both methods) and preterm birth (κ<0.29 for both methods). By LMP, 18% were judged premature compared with 6% by NB. LMP underestimated gestational age among women presenting later to prenatal care (0.18 weeks for each additional week). Gestational age for preterm infants was overestimated by nearly one week using LMP and nearly two weeks using NB. New Ballard neuromuscular measurements were more predictive of preterm birth than those measuring physical criteria. In an indigenous population in highland Guatemala, LMP overestimated prematurity by 2% and NB underestimated prematurity by 10% compared with ultrasound estimates. New, simple and accurate methods are needed to identify preterm birth in resource-limited settings worldwide.

  7. Determining gestational age and preterm birth in rural Guatemala: A comparison of methods

    PubMed Central

    Thompson, Lisa M.; Díaz Artiga, Anaité; Bryan, Joe P.; Arriaga, William E.; Omer, Saad B.; McCracken, John P.

    2018-01-01

    Background Preterm birth is the leading cause of death among children <5 years of age. Accurate determination of prematurity is necessary to provide appropriate neonatal care and guide preventive measures. To estimate the most accurate method to identify infants at risk for adverse outcomes, we assessed the validity of two widely available methods—last menstrual period (LMP) and the New Ballard (NB) neonatal assessment—against ultrasound in determining gestational age and preterm birth in highland Guatemala. Methods Pregnant women (n = 188) were recruited with a gestational age <20 weeks and followed until delivery. Ultrasound was performed by trained physicians and LMP was collected during recruitment. NB was performed on infants within 96 hours of birth by trained study nurses. LMP and NB accuracy at determining gestational age and identifying prematurity was assessed by comparing them to ultrasound. Results By ultrasound, infant mean gestational age at birth was 38.3 weeks (SD = 1.6) with 16% born at less than 37 gestation. LMP was more accurate than NB (mean difference of +0.13 weeks for LMP and +0.61 weeks for NB). However, LMP and NB estimates had low agreement with ultrasound-determined gestational age (Lin’s concordance<0.48 for both methods) and preterm birth (κ<0.29 for both methods). By LMP, 18% were judged premature compared with 6% by NB. LMP underestimated gestational age among women presenting later to prenatal care (0.18 weeks for each additional week). Gestational age for preterm infants was overestimated by nearly one week using LMP and nearly two weeks using NB. New Ballard neuromuscular measurements were more predictive of preterm birth than those measuring physical criteria. Conclusion In an indigenous population in highland Guatemala, LMP overestimated prematurity by 2% and NB underestimated prematurity by 10% compared with ultrasound estimates. New, simple and accurate methods are needed to identify preterm birth in resource-limited settings worldwide. PMID:29554145

  8. Valid statistical approaches for analyzing sholl data: Mixed effects versus simple linear models.

    PubMed

    Wilson, Machelle D; Sethi, Sunjay; Lein, Pamela J; Keil, Kimberly P

    2017-03-01

    The Sholl technique is widely used to quantify dendritic morphology. Data from such studies, which typically sample multiple neurons per animal, are often analyzed using simple linear models. However, simple linear models fail to account for intra-class correlation that occurs with clustered data, which can lead to faulty inferences. Mixed effects models account for intra-class correlation that occurs with clustered data; thus, these models more accurately estimate the standard deviation of the parameter estimate, which produces more accurate p-values. While mixed models are not new, their use in neuroscience has lagged behind their use in other disciplines. A review of the published literature illustrates common mistakes in analyses of Sholl data. Analysis of Sholl data collected from Golgi-stained pyramidal neurons in the hippocampus of male and female mice using both simple linear and mixed effects models demonstrates that the p-values and standard deviations obtained using the simple linear models are biased downwards and lead to erroneous rejection of the null hypothesis in some analyses. The mixed effects approach more accurately models the true variability in the data set, which leads to correct inference. Mixed effects models avoid faulty inference in Sholl analysis of data sampled from multiple neurons per animal by accounting for intra-class correlation. Given the widespread practice in neuroscience of obtaining multiple measurements per subject, there is a critical need to apply mixed effects models more widely. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Quantitative computed tomography for the prediction of pulmonary function after lung cancer surgery: a simple method using simulation software.

    PubMed

    Ueda, Kazuhiro; Tanaka, Toshiki; Li, Tao-Sheng; Tanaka, Nobuyuki; Hamano, Kimikazu

    2009-03-01

    The prediction of pulmonary functional reserve is mandatory in therapeutic decision-making for patients with resectable lung cancer, especially those with underlying lung disease. Volumetric analysis in combination with densitometric analysis of the affected lung lobe or segment with quantitative computed tomography (CT) helps to identify residual pulmonary function, although the utility of this modality needs investigation. The subjects of this prospective study were 30 patients with resectable lung cancer. A three-dimensional CT lung model was created with voxels representing normal lung attenuation (-600 to -910 Hounsfield units). Residual pulmonary function was predicted by drawing a boundary line between the lung to be preserved and that to be resected, directly on the lung model. The predicted values were correlated with the postoperative measured values. The predicted and measured values corresponded well (r=0.89, p<0.001). Although the predicted values corresponded with values predicted by simple calculation using a segment-counting method (r=0.98), there were two outliers whose pulmonary functional reserves were predicted more accurately by CT than by segment counting. The measured pulmonary functional reserves were significantly higher than the predicted values in patients with extensive emphysematous areas (<-910 Hounsfield units), but not in patients with chronic obstructive pulmonary disease. Quantitative CT yielded accurate prediction of functional reserve after lung cancer surgery and helped to identify patients whose functional reserves are likely to be underestimated. Hence, this modality should be utilized for patients with marginal pulmonary function.

  10. The potential impact of integrated malaria transmission control on entomologic inoculation rate in highly endemic areas.

    PubMed

    Killeen, G F; McKenzie, F E; Foy, B D; Schieffelin, C; Billingsley, P F; Beier, J C

    2000-05-01

    We have used a relatively simple but accurate model for predicting the impact of integrated transmission control on the malaria entomologic inoculation rate (EIR) at four endemic sites from across sub-Saharan Africa and the southwest Pacific. The simulated campaign incorporated modestly effective vaccine coverage, bed net use, and larval control. The results indicate that such campaigns would reduce EIRs at all four sites by 30- to 50-fold. Even without the vaccine, 15- to 25-fold reductions of EIR were predicted, implying that integrated control with a few modestly effective tools can meaningfully reduce malaria transmission in a range of endemic settings. The model accurately predicts the effects of bed nets and indoor spraying and demonstrates that they are the most effective tools available for reducing EIR. However, the impact of domestic adult vector control is amplified by measures for reducing the rate of emergence of vectors or the level of infectiousness of the human reservoir. We conclude that available tools, including currently neglected methods for larval control, can reduce malaria transmission intensity enough to alleviate mortality. Integrated control programs should be implemented to the fullest extent possible, even in areas of intense transmission, using simple models as decision-making tools. However, we also conclude that to eliminate malaria in many areas of intense transmission is beyond the scope of methods which developing nations can currently afford. New, cost-effective, practical tools are needed if malaria is ever to be eliminated from highly endemic areas.

  11. Three different methods for determination of binary mixture of Amlodipine and Atorvastatin using dual wavelength spectrophotometry

    NASA Astrophysics Data System (ADS)

    Darwish, Hany W.; Hassan, Said A.; Salem, Maissa Y.; El-Zeany, Badr A.

    2013-03-01

    Three simple, specific, accurate and precise spectrophotometric methods depending on the proper selection of two wavelengths are developed for the simultaneous determination of Amlodipine besylate (AML) and Atorvastatin calcium (ATV) in tablet dosage forms. The first method is the new Ratio Difference method, the second method is the Bivariate method and the third one is the Absorbance Ratio method. The calibration curve is linear over the concentration range of 4-40 and 8-32 μg/mL for AML and ATV, respectively. These methods are tested by analyzing synthetic mixtures of the above drugs and they are applied to commercial pharmaceutical preparation of the subjected drugs. Methods are validated according to the ICH guidelines and accuracy, precision, repeatability and robustness are found to be within the acceptable limit. The mathematical explanation of the procedures is illustrated.

  12. Titrimetric and photometric methods for determination of hypochlorite in commercial bleaches.

    PubMed

    Jonnalagadda, Sreekanth B; Gengan, Prabhashini

    2010-01-01

    Two methods, simple titration and photometric methods for determination of hypochlorite are developed, based its reaction with hydrogen peroxide and titration of the residual peroxide by acidic permanganate. In the titration method, the residual hydrogen peroxide is estimated by titration with standard permanganate solution to estimate the hypochlorite concentration. The photometric method is devised to measure the concentration of remaining permanganate, after the reaction with residual hydrogen peroxide. It employs 4 ranges of calibration curves to enable the determination of hypochlorite accurately. The new photometric method measures hypochlorite in the range 1.90 x 10(-3) to 1.90 x 10(-2) M, with high accuracy and with low variance. The concentrations of hypochlorite in diverse commercial bleach samples and in seawater which is enriched with hypochlorite were estimated using the proposed method and compared with the arsenite method. The statistical analysis validates the superiority of the proposed method.

  13. Comparative study between derivative spectrophotometry and multivariate calibration as analytical tools applied for the simultaneous quantitation of Amlodipine, Valsartan and Hydrochlorothiazide

    NASA Astrophysics Data System (ADS)

    Darwish, Hany W.; Hassan, Said A.; Salem, Maissa Y.; El-Zeany, Badr A.

    2013-09-01

    Four simple, accurate and specific methods were developed and validated for the simultaneous estimation of Amlodipine (AML), Valsartan (VAL) and Hydrochlorothiazide (HCT) in commercial tablets. The derivative spectrophotometric methods include Derivative Ratio Zero Crossing (DRZC) and Double Divisor Ratio Spectra-Derivative Spectrophotometry (DDRS-DS) methods, while the multivariate calibrations used are Principal Component Regression (PCR) and Partial Least Squares (PLSs). The proposed methods were applied successfully in the determination of the drugs in laboratory-prepared mixtures and in commercial pharmaceutical preparations. The validity of the proposed methods was assessed using the standard addition technique. The linearity of the proposed methods is investigated in the range of 2-32, 4-44 and 2-20 μg/mL for AML, VAL and HCT, respectively.

  14. Indirect enantioseparation of fluoxetine in mouse serum by derivatization with 1R-(-)-menthyl chloroformate followed by ultra high performance liquid chromatography and quadrupole time-of-flight mass spectrometry.

    PubMed

    Zhao, Jing; Jin, Yan; Shin, Yujin; Jeong, Kyung Min; Lee, Jeongmi

    2016-03-01

    Here we describe a simple and sensitive analytical method for the enantioselective quantification of fluoxetine in mouse serum using ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry. The sample preparation method included a simple deproteinization with acetonitrile in 50 μL of serum, followed by derivatization of the extracts in 50 μL of 2 mM 1R-(-)-menthyl chloroformate at 45ºC for 55 min. These conditions were statistically optimized through response surface methodology using a central composite design. Under the optimized conditions, neither racemization nor kinetic resolution occurred. The derivatized diastereomers were readily resolved on a conventional sub-2 μm C18 column under a simple gradient elution of aqueous methanol containing 0.1% formic acid. The established method was validated and found to be linear, precise, and accurate over the concentration range of 5.0-1000.0 ng/mL for both R and S enantiomers (r(2) > 0.993). Stability tests of the prepared samples at three different concentration levels showed that the R- and S-fluoxetine derivatives were relatively stable for 48 h. No significant matrix effects were observed. Last, the developed method was successfully used for enantiomeric analysis of real serum samples collected at a number of time points from mice administered with racemic fluoxetine. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Image analysis methods for assessing levels of image plane nonuniformity and stochastic noise in a magnetic resonance image of a homogeneous phantom.

    PubMed

    Magnusson, P; Olsson, L E

    2000-08-01

    Magnetic response image plane nonuniformity and stochastic noise are properties that greatly influence the outcome of quantitative magnetic resonance imaging (MRI) evaluations such as gel dosimetry measurements using MRI. To study these properties, robust and accurate image analysis methods are required. New nonuniformity level assessment methods were designed, since previous methods were found to be insufficiently robust and accurate. The new and previously reported nonuniformity level assessment methods were analyzed with respect to, for example, insensitivity to stochastic noise; and previously reported stochastic noise level assessment methods with respect to insensitivity to nonuniformity. Using the same image data, different methods were found to assess significantly different levels of nonuniformity. Nonuniformity levels obtained using methods that count pixels in an intensity interval, and obtained using methods that use only intensity values, were found not to be comparable. The latter were found preferable, since they assess the quantity intrinsically sought. A new method which calculates a deviation image, with every pixel representing the deviation from a reference intensity, was least sensitive to stochastic noise. Furthermore, unlike any other analyzed method, it includes all intensity variations across the phantom area and allows for studies of nonuniformity shapes. This new method was designed for accurate studies of nonuniformities in gel dosimetry measurements, but could also be used with benefit in quality assurance and acceptance testing of MRI, scintillation camera, and computer tomography systems. The stochastic noise level was found to be greatly method dependent. Two methods were found to be insensitive to nonuniformity and also simple to use in practice. One method assesses the stochastic noise level as the average of the levels at five different positions within the phantom area, and the other assesses the stochastic noise in a region outside the phantom area.

  16. Accurate Modeling of Galaxy Clustering on Small Scales: Testing the Standard ΛCDM + Halo Model

    NASA Astrophysics Data System (ADS)

    Sinha, Manodeep; Berlind, Andreas A.; McBride, Cameron; Scoccimarro, Roman

    2015-01-01

    The large-scale distribution of galaxies can be explained fairly simply by assuming (i) a cosmological model, which determines the dark matter halo distribution, and (ii) a simple connection between galaxies and the halos they inhabit. This conceptually simple framework, called the halo model, has been remarkably successful at reproducing the clustering of galaxies on all scales, as observed in various galaxy redshift surveys. However, none of these previous studies have carefully modeled the systematics and thus truly tested the halo model in a statistically rigorous sense. We present a new accurate and fully numerical halo model framework and test it against clustering measurements from two luminosity samples of galaxies drawn from the SDSS DR7. We show that the simple ΛCDM cosmology + halo model is not able to simultaneously reproduce the galaxy projected correlation function and the group multiplicity function. In particular, the more luminous sample shows significant tension with theory. We discuss the implications of our findings and how this work paves the way for constraining galaxy formation by accurate simultaneous modeling of multiple galaxy clustering statistics.

  17. Standardizing a simpler, more sensitive and accurate tail bleeding assay in mice

    PubMed Central

    Liu, Yang; Jennings, Nicole L; Dart, Anthony M; Du, Xiao-Jun

    2012-01-01

    AIM: To optimize the experimental protocols for a simple, sensitive and accurate bleeding assay. METHODS: Bleeding assay was performed in mice by tail tip amputation, immersing the tail in saline at 37 °C, continuously monitoring bleeding patterns and measuring bleeding volume from changes in the body weight. Sensitivity and extent of variation of bleeding time and bleeding volume were compared in mice treated with the P2Y receptor inhibitor prasugrel at various doses or in mice deficient of FcRγ, a signaling protein of the glycoprotein VI receptor. RESULTS: We described details of the bleeding assay with the aim of standardizing this commonly used assay. The bleeding assay detailed here was simple to operate and permitted continuous monitoring of bleeding pattern and detection of re-bleeding. We also reported a simple and accurate way of quantifying bleeding volume from changes in the body weight, which correlated well with chemical assay of hemoglobin levels (r2 = 0.990, P < 0.0001). We determined by tail bleeding assay the dose-effect relation of the anti-platelet drug prasugrel from 0.015 to 5 mg/kg. Our results showed that the correlation of bleeding time and volume was unsatisfactory and that compared with the bleeding time, bleeding volume was more sensitive in detecting a partial inhibition of platelet’s haemostatic activity (P < 0.01). Similarly, in mice with genetic disruption of FcRγ as a signaling molecule of P-selectin glycoprotein ligand-1 leading to platelet dysfunction, both increased bleeding volume and repeated bleeding pattern defined the phenotype of the knockout mice better than that of a prolonged bleeding time. CONCLUSION: Determination of bleeding pattern and bleeding volume, in addition to bleeding time, improved the sensitivity and accuracy of this assay, particularly when platelet function is partially inhibited. PMID:24520531

  18. A Simple Device to Measure Root Growth Rates

    ERIC Educational Resources Information Center

    Rauser, Wilfried E.; Horton, Roger F.

    1975-01-01

    Describes construction and use of a simple auxanometer which students can use to accurately measure root growth rates of intact seedlings. Typical time course data are presented for the effect of ethylene and indole acetic acid on pea root growth. (Author/BR)

  19. A simple animal support for convenient weighing

    USGS Publications Warehouse

    Pan, H.P.; Caslick, J.W.; Harke, D.T.; Decker, D.G.

    1965-01-01

    A simple animal support constructed of web belts to hold skittish pigs for weighing was developed. The support is easily made, noninjurious to the pigs, and compact, facilitating rapid, accurate weighing. With minor modifications, the support can probably be used in weighing other animals.

  20. Deposits from Creams Containing 20% (w/w) Urea and Suppression of Crystallization (Part 2): Novel Analytical Methods of Urea Accumulated in the Stratum Corneum by Tape stripping and Colorimetry.

    PubMed

    Goto, Norio; Morita, Yutaka; Terada, Katsuhide

    2016-01-01

    The transfer of urea from a urea formulation to the stratum corneum varies with the formulation base and form, and impacts the formulation's therapeutic effect. Consequently, determining the amount of urea transferred is essential for developing efficient formulations. This study assessed a simple method for measuring the amount of urea accumulated in the stratum corneum. Conventional methods rely on labeling urea used in the formulation with radiocarbon ((14)C) or other radioactive isotopes (RIs), retrieving the transferred urea from the stratum corneum by tape stripping, then quantitating the urea. The handling and use of RIs, however, is subject to legal regulation and can only be performed in sanctioned facilities, so methods employing RIs are neither simple nor convenient. We therefore developed a non-radiolabel method "tape stripping-colorimetry (T-C)" that combines tape stripping with colorimetry (urease-glutamate dehydrogenase (GLDH)) for the quantitative measurement of urea. Urea in the stratum corneum is collected by tape stripping and measured using urease-GLDH, which is commonly used to measure urea nitrogen in blood tests. The results indicate that accurate urea measurement by the T-C method requires the application of 1400 mg (on hairless rats) of a 20% urea solution on a 50 cm(2) (5×10 cm) area. Further, we determined the amount of urea accumulated in the stratum corneum using formulations with different urea concentrations, and the time course of urea accumulation from formulations differing in the rate of urea crystallization. We demonstrate that the T-C method is simple and convenient, with no need for (14)C or other RIs.

  1. Quantitative estimation of itopride hydrochloride and rabeprazole sodium from capsule formulation.

    PubMed

    Pillai, S; Singhvi, I

    2008-09-01

    Two simple, accurate, economical and reproducible UV spectrophotometric methods and one HPLC method for simultaneous estimation of two component drug mixture of itopride hydrochloride and rabeprazole sodium from combined capsule dosage form have been developed. First developed method involves formation and solving of simultaneous equations using 265.2 nm and 290.8 nm as two wavelengths. Second method is based on two wavelength calculation, wavelengths selected for estimation of itopride hydrochloride was 278.0 nm and 298.8 nm and for rabeprazole sodium 253.6 nm and 275.2 nm. Developed HPLC method is a reverse phase chromatographic method using phenomenex C(18) column and acetonitrile: phosphate buffer (35:65 v/v) pH 7.0 as mobile phase. All developed methods obey Beer's law in concentration range employed for respective methods. Results of analysis were validated statistically and by recovery studies.

  2. Quantitative Estimation of Itopride Hydrochloride and Rabeprazole Sodium from Capsule Formulation

    PubMed Central

    Pillai, S.; Singhvi, I.

    2008-01-01

    Two simple, accurate, economical and reproducible UV spectrophotometric methods and one HPLC method for simultaneous estimation of two component drug mixture of itopride hydrochloride and rabeprazole sodium from combined capsule dosage form have been developed. First developed method involves formation and solving of simultaneous equations using 265.2 nm and 290.8 nm as two wavelengths. Second method is based on two wavelength calculation, wavelengths selected for estimation of itopride hydrochloride was 278.0 nm and 298.8 nm and for rabeprazole sodium 253.6 nm and 275.2 nm. Developed HPLC method is a reverse phase chromatographic method using phenomenex C18 column and acetonitrile: phosphate buffer (35:65 v/v) pH 7.0 as mobile phase. All developed methods obey Beer's law in concentration range employed for respective methods. Results of analysis were validated statistically and by recovery studies. PMID:21394269

  3. Measurement of the residual stress distribution in a thick pre-stretched aluminum plate

    NASA Astrophysics Data System (ADS)

    Yuan, S. X.; Li, X. Q.; M, S.; Zhang, Y. C.; Gong, Y. D.

    2008-12-01

    Thick pre-stretched aluminum alloy plates are widely used in aircraft, while machining distortion caused by initial residual stress release in thick plates is a common and serious problem. To reduce the distortion, the residual stress distribution in thick plate must be measured. According to the characteristics of the thick pre-stretched aluminum alloy plate, based the elastic mechanical theory, this article deduces the modified layer-removal strain method adapting two different strain situations, which are caused by tensile and compressive stress. To validate this method, the residual stresses distribution along the thick direction of plate 2D70T351 is measured by this method, it is shown that the new method deduced in this paper is simple and accurate, and is very useful in engineering.

  4. Determination of total mercury in environmental and biological samples by flow injection cold vapour atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Murphy, James; Jones, Phil; Hill, Steve J.

    1996-12-01

    A simple and accurate method has been developed for the determination of total mercury in environmental and biological samples. The method utilises an off-line microwave digestion stage followed by analysis using a flow injection system with detection by cold vapour atomic absorption spectrometry. The method has been validated using two certified reference materials (DORM-1 dogfish and MESS-2 estuarine sediment) and the results agreed well with the certified values. A detection limit of 0.2 ng g -1 Hg was obtained and no significant interference was observed. The method was finally applied to the determination of mercury in river sediments and canned tuna fish, and gave results in the range 0.1-3.0 mg kg -1.

  5. Preconcentration of Sn (II) using the methylene blue on the activated carbon and its determination by spectrophotometry method.

    PubMed

    Khodadoust, Saeid; Cham Kouri, Narges

    2014-04-05

    A simple and accurate spectrophotometric method for determination of trace amounts of Sn (II) ion in soil sample was developed by using the methylene blue (MB) in the presence of activated carbon (AC) as the adsorbent Solid Phase Extraction (SPE) of Sn (II) and then determined by UV-Vis. The Beer's law is obeyed over the concentration range of 1-80ngmL(-1) of Sn (II) with the detection limits of 0.34ngmL(-1). The influence of type and volume of eluent, concentration of MB, pH, and amount of AC on sensitivity of spectrophotometric method were optimized. The method has been successfully applied for Sn (II) ion determination in soil sample. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. A semi-micromethod for determination of oxalate in human plasma.

    PubMed

    Porowski, Tadeusz; Gałasiński, Władysław

    2003-01-01

    An enzymatic semi-micromethod for oxalate determination in human plasma was elaborated. The principle of the method depends on the oxalate isolation from deproteinized plasma, following determination by the calorimetric oxalate oxidase-peroxidase-indamine system. This method protects against internal oxalate losses and excludes an interference of contaminations. Results, obtained by this method, were reliable and ideally suited for use as real normal values (less than or equal to 6 microM) of oxalate content in the plasma of healthy individuals. The elaborated method, which can assay plasma oxalate accurately in normal individuals as well as in hyperoxalemic conditions is superior to those previously used. The procedure of semi-micromethod does not require expensive equipments and apparatus: it is simple and easy to perform in every laboratory and takes little time.

  7. Functional renormalization group and Kohn-Sham scheme in density functional theory

    NASA Astrophysics Data System (ADS)

    Liang, Haozhao; Niu, Yifei; Hatsuda, Tetsuo

    2018-04-01

    Deriving accurate energy density functional is one of the central problems in condensed matter physics, nuclear physics, and quantum chemistry. We propose a novel method to deduce the energy density functional by combining the idea of the functional renormalization group and the Kohn-Sham scheme in density functional theory. The key idea is to solve the renormalization group flow for the effective action decomposed into the mean-field part and the correlation part. Also, we propose a simple practical method to quantify the uncertainty associated with the truncation of the correlation part. By taking the φ4 theory in zero dimension as a benchmark, we demonstrate that our method shows extremely fast convergence to the exact result even for the highly strong coupling regime.

  8. [Determination of acacetin in Xiangjuganmao Keli (no sweet) by HPLC].

    PubMed

    Bian, Jia-Hong; Qian, Kun; Xu, Xiang; Shen, Jun

    2006-11-01

    To establish a method for the determination of acacetin in Xiangjuganmao Keli (no sweet). Acacetin in powdered herb was extracted by ultrasonator with methanol and was hydrolyzed with hydrochloric acid. Separation was accomplished on an ODS reversed phase column (5 microm, 4.6 x 250 mm) with a mobile phase of methanol-water-acetic acid(350: 150: 2). The detective wavelength was at 340 nm. The method was accurate, the results were stable and reproducible. The linear range of calibration cure was within the concentration of 2.00 - 10.00 microg/ml (r = 0.9998). The average extraction recovery was 99.9% (n = 6), RSD = 0.41% (n = 6). The method is simple, convenient, sensitive, and reproducible for quality control of Xiangjuganmao Keli (no sweet).

  9. Remotely controlling of mobile robots using gesture captured by the Kinect and recognized by machine learning method

    NASA Astrophysics Data System (ADS)

    Hsu, Roy CHaoming; Jian, Jhih-Wei; Lin, Chih-Chuan; Lai, Chien-Hung; Liu, Cheng-Ting

    2013-01-01

    The main purpose of this paper is to use machine learning method and Kinect and its body sensation technology to design a simple, convenient, yet effective robot remote control system. In this study, a Kinect sensor is used to capture the human body skeleton with depth information, and a gesture training and identification method is designed using the back propagation neural network to remotely command a mobile robot for certain actions via the Bluetooth. The experimental results show that the designed mobile robots remote control system can achieve, on an average, more than 96% of accurate identification of 7 types of gestures and can effectively control a real e-puck robot for the designed commands.

  10. Split Node and Stress Glut Methods for Dynamic Rupture Simulations in Finite Elements.

    NASA Astrophysics Data System (ADS)

    Ramirez-Guzman, L.; Bielak, J.

    2008-12-01

    I present two numerical techniques to solve the Dynamic problem. I revisit and modify the Split Node approach and introduce a Stress Glut type Method. Both algorithms are implemented using a iso/sub- parametric FEM solver. In the first case, I discuss the formulation and perform an analysis of convergence for different orders of approximation for the acoustic case. I describe the algorithm of the second methodology as well as the assumptions made. The key to the new technique is to have an accurate representation of the traction. Thus, I devote part of the discussion to analyze the tractions for a simple example. The sensitivity of the method is tested by comparing against Split Node solutions.

  11. Parallel tempering for the traveling salesman problem

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Percus, Allon; Wang, Richard; Hyman, Jeffrey

    We explore the potential of parallel tempering as a combinatorial optimization method, applying it to the traveling salesman problem. We compare simulation results of parallel tempering with a benchmark implementation of simulated annealing, and study how different choices of parameters affect the relative performance of the two methods. We find that a straightforward implementation of parallel tempering can outperform simulated annealing in several crucial respects. When parameters are chosen appropriately, both methods yield close approximation to the actual minimum distance for an instance with 200 nodes. However, parallel tempering yields more consistently accurate results when a series of independent simulationsmore » are performed. Our results suggest that parallel tempering might offer a simple but powerful alternative to simulated annealing for combinatorial optimization problems.« less

  12. Spectrophotometric determination of some histamine H1-antagonists drugs in their pharmaceutical preparations.

    PubMed

    Hassan, Wafaa S; El-Henawee, Magda M; Gouda, Ayman A

    2008-01-01

    Two rapid, simple and sensitive extractive specrophotometric methods has been developed for the determination of three histamine H1-antagonists drugs, e.g., chlorphenoxamine hydrochloride (CPX), diphenhydramine hydrochloride (DPH) and clemastine (CMT) in bulk and in their pharmaceutical formulations. The first method depend upon the reaction of molybdenum(V) thiocyanate ions (Method A) with the cited drugs to form stable ion-pair complexes which extractable with methylene chloride, the orange red color complex was determined colorimetrically at lambda(max) 470nm. The second method is based on the formation of an ion-association complex with alizarin red S as chromogenic reagents in acidic medium (Method B), which is extracted into chloroform. The complexes have a maximum absorbance at 425 and 426nm for (DPH or CMT) and CPX, respectively. Regression analysis of Beer-Lambert plots showed a good correlation in the concentration ranges of 5.0-40 and 5-70microgmL(-1) for molybdenum(V) thiocyanate (Method A) and alizarin red S (Method B), respectively. For more accurate analysis, Ringbom optimum concentration ranges were calculated. The molar absorptivity, Sandell sensitivity, detection and quantification limits were calculated. Applications of the procedure to the analysis of various pharmaceutical preparations gave reproducible and accurate results. Further, the validity of the procedure was confirmed by applying the standard addition technique and the results obtained in good agreement well with those obtained by the official method.

  13. Spectrophotometric determination of some histamine H1-antagonists drugs in their pharmaceutical preparations

    NASA Astrophysics Data System (ADS)

    Hassan, Wafaa S.; El-Henawee, Magda M.; Gouda, Ayman A.

    2008-01-01

    Two rapid, simple and sensitive extractive specrophotometric methods has been developed for the determination of three histamine H1-antagonists drugs, e.g., chlorphenoxamine hydrochloride (CPX), diphenhydramine hydrochloride (DPH) and clemastine (CMT) in bulk and in their pharmaceutical formulations. The first method depend upon the reaction of molybdenum(V) thiocyanate ions (Method A) with the cited drugs to form stable ion-pair complexes which extractable with methylene chloride, the orange red color complex was determined colorimetrically at λmax 470 nm. The second method is based on the formation of an ion-association complex with alizarin red S as chromogenic reagents in acidic medium (Method B), which is extracted into chloroform. The complexes have a maximum absorbance at 425 and 426 nm for (DPH or CMT) and CPX, respectively. Regression analysis of Beer-Lambert plots showed a good correlation in the concentration ranges of 5.0-40 and 5-70 μg mL -1 for molybdenum(V) thiocyanate (Method A) and alizarin red S (Method B), respectively. For more accurate analysis, Ringbom optimum concentration ranges were calculated. The molar absorptivity, Sandell sensitivity, detection and quantification limits were calculated. Applications of the procedure to the analysis of various pharmaceutical preparations gave reproducible and accurate results. Further, the validity of the procedure was confirmed by applying the standard addition technique and the results obtained in good agreement well with those obtained by the official method.

  14. Reliability of the Parabola Approximation Method in Heart Rate Variability Analysis Using Low-Sampling-Rate Photoplethysmography.

    PubMed

    Baek, Hyun Jae; Shin, JaeWook; Jin, Gunwoo; Cho, Jaegeol

    2017-10-24

    Photoplethysmographic signals are useful for heart rate variability analysis in practical ambulatory applications. While reducing the sampling rate of signals is an important consideration for modern wearable devices that enable 24/7 continuous monitoring, there have not been many studies that have investigated how to compensate the low timing resolution of low-sampling-rate signals for accurate heart rate variability analysis. In this study, we utilized the parabola approximation method and measured it against the conventional cubic spline interpolation method for the time, frequency, and nonlinear domain variables of heart rate variability. For each parameter, the intra-class correlation, standard error of measurement, Bland-Altman 95% limits of agreement and root mean squared relative error were presented. Also, elapsed time taken to compute each interpolation algorithm was investigated. The results indicated that parabola approximation is a simple, fast, and accurate algorithm-based method for compensating the low timing resolution of pulse beat intervals. In addition, the method showed comparable performance with the conventional cubic spline interpolation method. Even though the absolute value of the heart rate variability variables calculated using a signal sampled at 20 Hz were not exactly matched with those calculated using a reference signal sampled at 250 Hz, the parabola approximation method remains a good interpolation method for assessing trends in HRV measurements for low-power wearable applications.

  15. Development and validation of a rapid and simple LC-MS/MS method for quantification of vemurafenib in human plasma: application to a human pharmacokinetic study.

    PubMed

    Bihan, Kevin; Sauzay, Chloé; Goldwirt, Lauriane; Charbonnier-Beaupel, Fanny; Hulot, Jean-Sebastien; Funck-Brentano, Christian; Zahr, Noël

    2015-02-01

    Vemurafenib (Zelboraf) is a new tyrosine kinase inhibitor that selectively targets activated BRAF V600E gene and is indicated for the treatment of advanced BRAF mutation-positive melanoma. We developed a simple method for vemurafenib quantification using liquid chromatography-tandem mass spectrometry. A stability study of vemurafenib in human plasma was also performed. (13)C(6)-vemurafenib was used as the internal standard. A single-step protein precipitation was used for plasma sample preparation. Chromatography was performed on an Acquity UPLC system (Waters) with chromatographic separation by the use of an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7-mm particle size; Waters). Quantification was performed using the monitoring of multiple reactions of following transitions: m/z 488.2 → 381.0 for vemurafenib and m/z 494.2 → 387.0 for internal standard. This method was linear over the range from 1.0 to 100.0 mcg/mL. The lower limit of quantification was 0.1 mcg/mL for vemurafenib in plasma. Vemurafenib remained stable for 1 month at all levels tested, when stored indifferently at room temperature (20 °C), at +4 °C, or at -20 °C. This method was used successfully to perform a plasma pharmacokinetic study of vemurafenib in a patient after oral administration at a steady state. This liquid chromatography-tandem mass spectrometry method for vemurafenib quantification in human plasma is simple, rapid, specific, sensitive, accurate, precise, and reliable.

  16. An efficient hybrid technique in RCS predictions of complex targets at high frequencies

    NASA Astrophysics Data System (ADS)

    Algar, María-Jesús; Lozano, Lorena; Moreno, Javier; González, Iván; Cátedra, Felipe

    2017-09-01

    Most computer codes in Radar Cross Section (RCS) prediction use Physical Optics (PO) and Physical theory of Diffraction (PTD) combined with Geometrical Optics (GO) and Geometrical Theory of Diffraction (GTD). The latter approaches are computationally cheaper and much more accurate for curved surfaces, but not applicable for the computation of the RCS of all surfaces of a complex object due to the presence of caustic problems in the analysis of concave surfaces or flat surfaces in the far field. The main contribution of this paper is the development of a hybrid method based on a new combination of two asymptotic techniques: GTD and PO, considering the advantages and avoiding the disadvantages of each of them. A very efficient and accurate method to analyze the RCS of complex structures at high frequencies is obtained with the new combination. The proposed new method has been validated comparing RCS results obtained for some simple cases using the proposed approach and RCS using the rigorous technique of Method of Moments (MoM). Some complex cases have been examined at high frequencies contrasting the results with PO. This study shows the accuracy and the efficiency of the hybrid method and its suitability for the computation of the RCS at really large and complex targets at high frequencies.

  17. Determination of dasatinib in the tablet dosage form by ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis.

    PubMed

    Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel

    2017-01-01

    Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Calculation of water equivalent thickness of materials of arbitrary density, elemental composition and thickness in proton beam irradiation

    NASA Astrophysics Data System (ADS)

    Zhang, Rui; Newhauser, Wayne D.

    2009-03-01

    In proton therapy, the radiological thickness of a material is commonly expressed in terms of water equivalent thickness (WET) or water equivalent ratio (WER). However, the WET calculations required either iterative numerical methods or approximate methods of unknown accuracy. The objective of this study was to develop a simple deterministic formula to calculate WET values with an accuracy of 1 mm for materials commonly used in proton radiation therapy. Several alternative formulas were derived in which the energy loss was calculated based on the Bragg-Kleeman rule (BK), the Bethe-Bloch equation (BB) or an empirical version of the Bethe-Bloch equation (EBB). Alternative approaches were developed for targets that were 'radiologically thin' or 'thick'. The accuracy of these methods was assessed by comparison to values from an iterative numerical method that utilized evaluated stopping power tables. In addition, we also tested the approximate formula given in the International Atomic Energy Agency's dosimetry code of practice (Technical Report Series No 398, 2000, IAEA, Vienna) and stopping power ratio approximation. The results of these comparisons revealed that most methods were accurate for cases involving thin or low-Z targets. However, only the thick-target formulas provided accurate WET values for targets that were radiologically thick and contained high-Z material.

  19. Accurate Monte Carlo simulations on FCC and HCP Lennard-Jones solids at very low temperatures and high reduced densities up to 1.30

    NASA Astrophysics Data System (ADS)

    Adidharma, Hertanto; Tan, Sugata P.

    2016-07-01

    Canonical Monte Carlo simulations on face-centered cubic (FCC) and hexagonal closed packed (HCP) Lennard-Jones (LJ) solids are conducted at very low temperatures (0.10 ≤ T∗ ≤ 1.20) and high densities (0.96 ≤ ρ∗ ≤ 1.30). A simple and robust method is introduced to determine whether or not the cutoff distance used in the simulation is large enough to provide accurate thermodynamic properties, which enables us to distinguish the properties of FCC from that of HCP LJ solids with confidence, despite their close similarities. Free-energy expressions derived from the simulation results are also proposed, not only to describe the properties of those individual structures but also the FCC-liquid, FCC-vapor, and FCC-HCP solid phase equilibria.

  20. Sum-rule corrections: A route to error cancellations in correlation matrix renormalisation theory

    DOE PAGES

    Liu, C.; Liu, J.; Yao, Y. X.; ...

    2017-01-16

    Here, we recently proposed the correlation matrix renormalisation (CMR) theory to efficiently and accurately calculate ground state total energy of molecular systems, based on the Gutzwiller variational wavefunction (GWF) to treat the electronic correlation effects. To help reduce numerical complications and better adapt the CMR to infinite lattice systems, we need to further refine the way to minimise the error originated from the approximations in the theory. This conference proceeding reports our recent progress on this key issue, namely, we obtained a simple analytical functional form for the one-electron renormalisation factors, and introduced a novel sum-rule correction for a moremore » accurate description of the intersite electron correlations. Benchmark calculations are performed on a set of molecules to show the reasonable accuracy of the method.« less

Top