Elliott, Rachel A; Putman, Koen D; Franklin, Matthew; Annemans, Lieven; Verhaeghe, Nick; Eden, Martin; Hayre, Jasdeep; Rodgers, Sarah; Sheikh, Aziz; Avery, Anthony J
2014-06-01
We recently showed that a pharmacist-led information technology-based intervention (PINCER) was significantly more effective in reducing medication errors in general practices than providing simple feedback on errors, with cost per error avoided at £79 (US$131). We aimed to estimate cost effectiveness of the PINCER intervention by combining effectiveness in error reduction and intervention costs with the effect of the individual errors on patient outcomes and healthcare costs, to estimate the effect on costs and QALYs. We developed Markov models for each of six medication errors targeted by PINCER. Clinical event probability, treatment pathway, resource use and costs were extracted from literature and costing tariffs. A composite probabilistic model combined patient-level error models with practice-level error rates and intervention costs from the trial. Cost per extra QALY and cost-effectiveness acceptability curves were generated from the perspective of NHS England, with a 5-year time horizon. The PINCER intervention generated £2,679 less cost and 0.81 more QALYs per practice [incremental cost-effectiveness ratio (ICER): -£3,037 per QALY] in the deterministic analysis. In the probabilistic analysis, PINCER generated 0.001 extra QALYs per practice compared with simple feedback, at £4.20 less per practice. Despite this extremely small set of differences in costs and outcomes, PINCER dominated simple feedback with a mean ICER of -£3,936 (standard error £2,970). At a ceiling 'willingness-to-pay' of £20,000/QALY, PINCER reaches 59 % probability of being cost effective. PINCER produced marginal health gain at slightly reduced overall cost. Results are uncertain due to the poor quality of data to inform the effect of avoiding errors.
Heil, John R; Nordeste, Ricardo F; Charles, Trevor C
2011-04-01
Here we report a simple cost-effective device for screening colonies on plates for expression of the monomeric red fluorescent protein mRFP1 and the fluorescent dye Nile red. This device can be built from any simple light source, in our case a Quebec Colony Counter, and cost-effective theatre gels. The device can be assembled in as little as 20 min, and it produces excellent results when screening a large number of colonies.
ERIC Educational Resources Information Center
Downs, Nathan; Larsen, Kim; Parisi, Alfio; Schouten, Peter; Brennan, Chris
2012-01-01
A practical exercise for developing a simple cost-effective solar ultraviolet radiation dosimeter is presented for use by middle school science students. Specifically, this exercise investigates a series of experiments utilising the historical blue print reaction, combining ammonium iron citrate and potassium hexacyanoferrate to develop an…
Courville, Xan F; Tomek, Ivan M; Kirkland, Kathryn B; Birhle, Marian; Kantor, Stephen R; Finlayson, Samuel R G
2012-02-01
To perform a cost-effectiveness analysis to evaluate preoperative use of mupirocin in patients with total joint arthroplasty (TJA). Simple decision tree model. Outpatient TJA clinical setting. Hypothetical cohort of patients with TJA. A simple decision tree model compared 3 strategies in a hypothetical cohort of patients with TJA: (1) obtaining preoperative screening cultures for all patients, followed by administration of mupirocin to patients with cultures positive for Staphylococcus aureus; (2) providing empirical preoperative treatment with mupirocin for all patients without screening; and (3) providing no preoperative treatment or screening. We assessed the costs and benefits over a 1-year period. Data inputs were obtained from a literature review and from our institution's internal data. Utilities were measured in quality-adjusted life-years, and costs were measured in 2005 US dollars. Incremental cost-effectiveness ratio. The treat-all and screen-and-treat strategies both had lower costs and greater benefits, compared with the no-treatment strategy. Sensitivity analysis revealed that this result is stable even if the cost of mupirocin was over $100 and the cost of SSI ranged between $26,000 and $250,000. Treating all patients remains the best strategy when the prevalence of S. aureus carriers and surgical site infection is varied across plausible values as well as when the prevalence of mupirocin-resistant strains is high. Empirical treatment with mupirocin ointment or use of a screen-and-treat strategy before TJA is performed is a simple, safe, and cost-effective intervention that can reduce the risk of SSI. S. aureus decolonization with nasal mupirocin for patients undergoing TJA should be considered. Level II, economic and decision analysis.
The Instructional Cost Index. A Simplified Approach to Interinstitutional Cost Comparison.
ERIC Educational Resources Information Center
Beatty, George, Jr.; And Others
The paper describes a simple, yet effective method of computing a comparative index of instructional costs. The Instructional Cost Index identifies direct cost differentials among instructional programs. Cost differentials are described in terms of differences among numerical values of variables that reflect fundamental academic and resource…
Cost-effectiveness of surgery in low- and middle-income countries: a systematic review.
Grimes, Caris E; Henry, Jaymie Ang; Maraka, Jane; Mkandawire, Nyengo C; Cotton, Michael
2014-01-01
There is increasing interest in provision of essential surgical care as part of public health policy in low- and middle-income countries (LMIC). Relatively simple interventions have been shown to prevent death and disability. We reviewed the published literature to examine the cost-effectiveness of simple surgical interventions which could be made available at any district hospital, and compared these to standard public health interventions. PubMed and EMBASE were searched using single and combinations of the search terms "disability adjusted life year" (DALY), "quality adjusted life year," "cost-effectiveness," and "surgery." Articles were included if they detailed the cost-effectiveness of a surgical intervention of relevance to a LMIC, which could be made available at any district hospital. Suitable articles with both cost and effectiveness data were identified and, where possible, data were extrapolated to enable comparison across studies. Twenty-seven articles met our inclusion criteria, representing 64 LMIC over 16 years of study. Interventions that were found to be cost-effective included cataract surgery (cost/DALY averted range US$5.06-$106.00), elective inguinal hernia repair (cost/DALY averted range US$12.88-$78.18), male circumcision (cost/DALY averted range US$7.38-$319.29), emergency cesarean section (cost/DALY averted range US$18-$3,462.00), and cleft lip and palate repair (cost/DALY averted range US$15.44-$96.04). A small district hospital with basic surgical services was also found to be highly cost-effective (cost/DALY averted 1 US$0.93), as were larger hospitals offering emergency and trauma surgery (cost/DALY averted US$32.78-$223.00). This compares favorably with other standard public health interventions, such as oral rehydration therapy (US$1,062.00), vitamin A supplementation (US$6.00-$12.00), breast feeding promotion (US$930.00), and highly active anti-retroviral therapy for HIV (US$922.00). Simple surgical interventions that are life-saving and disability-preventing should be considered as part of public health policy in LMIC. We recommend an investment in surgical care and its integration with other public health measures at the district hospital level, rather than investment in single disease strategies.
Invisible Cost Effective Mechanics for Anterior Space Closure.
Jumle, Aatish Vinod; Bagrecha, Saurabh; Gharat, Ninad; Misal, Abhijit; Toshniwal, N G
2015-01-01
The shifting paradigm towards invisible orthodontic treatment and also awareness in patients has allured their focus towards the most esthetic treatment approach. Also the lingual treatment is proved successful and is very well accepted by the patients. The problem that persist is its high expenses, which is not affordable by all patients. This article is a effort to treat a simple Class I malocclusion with anterior spacing using a simple, esthetic, Cost effective approach with acceptable results when esthetics plays a priority role.
Simple Levelized Cost of Energy (LCOE) Calculator Documentation | Energy
Analysis | NREL Simple Levelized Cost of Energy (LCOE) Calculator Documentation Simple Levelized Cost of Energy (LCOE) Calculator Documentation Transparent Cost Database Button This is a simple : 1). Cost and Performance Adjust the sliders to suitable values for each of the cost and performance
Simple economic evaluation and applications experiments for photovoltaic systems for remote sites
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rios, M. Jr.
1980-01-01
A simple evaluation of the cost effectiveness of photovoltaic systems is presented. The evaluation is based on a calculation of breakeven costs of photovoltaics (PV) arrays with the levelized costs of two alternative energy sources (1) extension of the utility grid and (2) diesel generators. A selected number of PV applications experiments that are in progress in remote areas of the US are summarized. These applications experiments range from a 23 watt insect survey trap to a 100 kW PV system for a national park complex. It is concluded that PV systems for remote areas are now cost effective inmore » remote small applications with commercially available technology and will be cost competitive for intermediate scale systems (approx. 10 kW) in the 1980s if the DOE 1986 Commercial Readiness Goals are achieved.« less
10 CFR 455.63 - Cost-effectiveness testing.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) The simple payback period of each energy conservation measure (except measures to shift demand, or...), by the estimated annual cost savings accruing from the measure (adjusted for demand charges), as... non-renewable fuels displaced less the annual cost of the renewable fuel, if any, and the annual cost...
10 CFR 455.63 - Cost-effectiveness testing.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) The simple payback period of each energy conservation measure (except measures to shift demand, or...), by the estimated annual cost savings accruing from the measure (adjusted for demand charges), as... non-renewable fuels displaced less the annual cost of the renewable fuel, if any, and the annual cost...
Technology in rural transportation: "Simple Solutions"
DOT National Transportation Integrated Search
1997-10-01
The Rural Outreach Project: Simple Solutions Report contains the findings of a research effort aimed at identifying and describing proven, cost-effective, low-tech solutions for rural transportation-related problems or needs. Through a process ...
Simple Demonstration of the Seebeck Effect
ERIC Educational Resources Information Center
Molki, Arman
2010-01-01
In this article we propose a simple and low-cost experimental set-up through which science educators can demonstrate the Seebeck effect using a thermocouple and an instrumentation amplifier. The experiment can be set up and conducted during a 1-hour laboratory session. (Contains 3 tables and 3 figures.)
Energy survey study and report of hospitals in Chicago: South Suburban Hospital: Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1988-08-01
This study is part of a three-phased demonstration project to reduce energy consumption in hospitals through practical life-cycle/cost-effective modifications and alteration. Funds for the demonstration project are provided by the American Hospital Association (AHA), the Department of Energy (DOE), and the Department of Health and Human Services (DHHS). A thorough study and evaluation of all building systems is made to identify opportunities for reduction in energy consumption and to determine the most cost effective approaches to energy conservation. The primary objective of the study is to investigate and analyze energy usage of the facility and to identify all life cycle,more » cost-effective changes required to effect a reduction in energy consumption. For the purpose of economic evaluation of the energy conservation projects identified, life-cycle cost and simple payback periods are used. Energy conservation measures with simple payback periods exceeding five years were dismissed from further detailed study.« less
Hoch, Jeffrey S; Dewa, Carolyn S
2014-04-01
Economic evaluations commonly accompany trials of new treatments or interventions; however, regression methods and their corresponding advantages for the analysis of cost-effectiveness data are not well known. To illustrate regression-based economic evaluation, we present a case study investigating the cost-effectiveness of a collaborative mental health care program for people receiving short-term disability benefits for psychiatric disorders. We implement net benefit regression to illustrate its strengths and limitations. Net benefit regression offers a simple option for cost-effectiveness analyses of person-level data. By placing economic evaluation in a regression framework, regression-based techniques can facilitate the analysis and provide simple solutions to commonly encountered challenges. Economic evaluations of person-level data (eg, from a clinical trial) should use net benefit regression to facilitate analysis and enhance results.
The Production Effect: Costs and Benefits in Free Recall
ERIC Educational Resources Information Center
Jones, Angela C.; Pyc, Mary A.
2014-01-01
The production effect, the memorial benefit for information read aloud versus silently, has been touted as a simple memory improvement tool. The current experiments were designed to evaluate the relative costs and benefits of production using a free recall paradigm. Results extend beyond prior work showing a production effect only when production…
A simple and low-cost biofilm quantification method using LED and CMOS image sensor.
Kwak, Yeon Hwa; Lee, Junhee; Lee, Junghoon; Kwak, Soo Hwan; Oh, Sangwoo; Paek, Se-Hwan; Ha, Un-Hwan; Seo, Sungkyu
2014-12-01
A novel biofilm detection platform, which consists of a cost-effective red, green, and blue light-emitting diode (RGB LED) as a light source and a lens-free CMOS image sensor as a detector, is designed. This system can measure the diffraction patterns of cells from their shadow images, and gather light absorbance information according to the concentration of biofilms through a simple image processing procedure. Compared to a bulky and expensive commercial spectrophotometer, this platform can provide accurate and reproducible biofilm concentration detection and is simple, compact, and inexpensive. Biofilms originating from various bacterial strains, including Pseudomonas aeruginosa (P. aeruginosa), were tested to demonstrate the efficacy of this new biofilm detection approach. The results were compared with the results obtained from a commercial spectrophotometer. To utilize a cost-effective light source (i.e., an LED) for biofilm detection, the illumination conditions were optimized. For accurate and reproducible biofilm detection, a simple, custom-coded image processing algorithm was developed and applied to a five-megapixel CMOS image sensor, which is a cost-effective detector. The concentration of biofilms formed by P. aeruginosa was detected and quantified by varying the indole concentration, and the results were compared with the results obtained from a commercial spectrophotometer. The correlation value of the results from those two systems was 0.981 (N = 9, P < 0.01) and the coefficients of variation (CVs) were approximately threefold lower at the CMOS image-sensor platform. Copyright © 2014 Elsevier B.V. All rights reserved.
Time- and cost-saving apparatus for analytical sample filtration
William R. Kenealy; Joseph C. Destree
2005-01-01
Simple and cost-effective protocols were developed for removing particulates from samples prior to analysis by high performance liquid chromatography and gas chromatography. A filter and vial holder were developed for use with a 96-well filtration plate. The device saves preparation time and costs.
Use of a Tea Infuser to Submerge Low-Density Dry Ice
ERIC Educational Resources Information Center
Fictorie, Carl P.; Vitz, Ed
2004-01-01
A simple tea infuser is obtained and been used as a container for the dry ice to simulate the effect from high-density dry ice. The tea infuser is a simple, low cost device to allow instructors with access to dry ice makers to effectively use the interesting demonstration.
Chen, Shuming; Kwok, Hoi Sing
2010-01-04
Light extraction from organic light-emitting diodes (OLEDs) by scattering the light is one of the effective methods for large-area lighting applications. In this paper, we present a very simple and cost-effective method to rough the substrates and hence to scatter the light. By simply sand-blasting the edges and back-side surface of the glass substrates, a 20% improvement of forward efficiency has been demonstrated. Moreover, due to scattering effect, a constant color over all viewing angles and uniform light pattern with Lambertian distribution has been obtained. This simple and cost-effective method may be suitable for mass production of large-area OLEDs for lighting applications.
7 CFR 4288.21 - Application review and scoring.
Code of Federal Regulations, 2013 CFR
2013-01-01
... projects based on the cost, cost-effectiveness, and capacity of projects to reduce fossil fuels. The cost... economically produce energy from renewable biomass to replace its dependence on fossil fuels. Projects with... projects on simple payback as well as the percentage of fossil fuel reduction. (a) Review. The Agency will...
7 CFR 4288.21 - Application review and scoring.
Code of Federal Regulations, 2014 CFR
2014-01-01
... projects based on the cost, cost-effectiveness, and capacity of projects to reduce fossil fuels. The cost... economically produce energy from renewable biomass to replace its dependence on fossil fuels. Projects with... projects on simple payback as well as the percentage of fossil fuel reduction. (a) Review. The Agency will...
7 CFR 4288.21 - Application review and scoring.
Code of Federal Regulations, 2012 CFR
2012-01-01
... projects based on the cost, cost-effectiveness, and capacity of projects to reduce fossil fuels. The cost... economically produce energy from renewable biomass to replace its dependence on fossil fuels. Projects with... projects on simple payback as well as the percentage of fossil fuel reduction. (a) Review. The Agency will...
NASA Astrophysics Data System (ADS)
Oleksandrov, Sergiy; Kwon, Jung Ho; Lee, Ki-chang; Sujin-Ku; Paek, Mun Cheol
2014-09-01
This work introduces a novel chip to be used in the future as a simple and cost-effective method for creating DNA arrays using light emission diode (LED) photolithography. The DNA chip platform contains 24 independent reaction sites, which allows for the testing of a corresponding amount of patients' samples in hospital. An array of commercial UV LEDs and lens systems was combined with a microfluidic flow system to provide patterning of 24 individual reaction sites, each with 64 independent probes. Using the LED array instead of conventional laser exposure systems or micro-mirror systems significantly reduces the cost of equipment. The microfluidic system together with microfluidic flow cells drastically reduces the amount of used reagents, which is important due to the high cost of commercial reagents. The DNA synthesis efficiency was verified by fluorescence labeling and conventional hybridization.
McGrath, Brian; Buckius, Michelle T; Grim, Rod; Bell, Theodore; Ahuja, Vanita
2011-12-01
Laparoscopic appendectomy (LA) has become more acceptable for the treatment of appendicitis over the last decade; however, its cost benefit compared to open appendectomy (OA) remains under debate. The purpose of this study is to evaluate the utilization of LA and its cost effectiveness based on total hospital charges stratified by complexity of disease and complications compared to OA. Nationwide Inpatient Sample data from 1998 to 2008 with the principal diagnosis of appendicitis were included. Appendicitis cases were divided by simple and complex (peritonitis or abscess) and subdivided by OA, LA, and lap converted to open (CONV). Total charges (2008 value), length of stay (LOS), and complications were assessed by disease presentation and operative approach. Between 1998 and 2008, 1,561,518 (54.3%) OA, 1,231,643 (42.8%) LA, and 84,662 (2.9%) CONV appendectomies were performed. LA had shorter LOS (2 d) than OA (3 d) and CONV (5 d) (P<0.001). CONV (7.4%) cases had more complications than OA (3.7%) and LA (2.6%). LA ($19,978) and CONV ($28,103) are costlier than OA ($15,714) based on normalized cost for simple and complex diseases (P<0.001). LA is more prevalent but its cost is higher in both simple and complex cases. Cost and complications increase if the case is converted to open. OA remains the most cost effective approach for patients with acute appendicitis. Copyright © 2011 Elsevier Inc. All rights reserved.
Rome, K; Clark, H; Gray, J; McMeekin, P; Plant, M; Dixon, J
2017-05-01
Foot orthoses are commonly prescribed as an intervention for people with rheumatoid arthritis (RA). Data relating to the cost-effectiveness of foot orthoses in people with RA are limited. The aim was to evaluate the clinical and cost-effectiveness of two types of foot orthoses in people with established RA. A single-blind randomized controlled trial was undertaken to compare custom-made foot orthoses (CMFOs) and simple insoles (SIs) in 41 people with established RA. The Foot Function Index (FFI) was used to measure foot pain, disability, and functional limitation. Costs were estimated from the perspective of the UK National Health Service (NHS), societal (patient and family) perspective, and secondary care resource use in terms of the intervention and staff time. Effects were assessed in terms of health gain expressed as quality-adjusted life years (QALYs). At baseline, 20 participants received a CMFO and 21 participants received an SI. After 16 weeks foot pain improved in both the CMFOs (p = 0.000) and the SIs (p < 0.01). However, disability scores improved for CMFOs (p < 0.001) but not for SIs (p = 0.40). The cost-effectiveness results demonstrated no difference in cost between the arms (CMFOs: £159.10; SIs: £79.10; p = 0.35), with the CMFOs being less effective in terms of cost per QALY gain (p < 0.001). In people with established RA, semi-rigid customized foot orthoses can improve pain and disability scores in comparison to simple insoles. From a cost-effectiveness perspective, the customized foot orthoses were far more expensive to manufacture, with no significant cost per QALY gain.
Urban Land Cover Mapping Accuracy Assessment - A Cost-benefit Analysis Approach
NASA Astrophysics Data System (ADS)
Xiao, T.
2012-12-01
One of the most important components in urban land cover mapping is mapping accuracy assessment. Many statistical models have been developed to help design simple schemes based on both accuracy and confidence levels. It is intuitive that an increased number of samples increases the accuracy as well as the cost of an assessment. Understanding cost and sampling size is crucial in implementing efficient and effective of field data collection. Few studies have included a cost calculation component as part of the assessment. In this study, a cost-benefit sampling analysis model was created by combining sample size design and sampling cost calculation. The sampling cost included transportation cost, field data collection cost, and laboratory data analysis cost. Simple Random Sampling (SRS) and Modified Systematic Sampling (MSS) methods were used to design sample locations and to extract land cover data in ArcGIS. High resolution land cover data layers of Denver, CO and Sacramento, CA, street networks, and parcel GIS data layers were used in this study to test and verify the model. The relationship between the cost and accuracy was used to determine the effectiveness of each sample method. The results of this study can be applied to other environmental studies that require spatial sampling.
A Simple and Effective Program to Increase Faculty Knowledge of and Referrals to Counseling Centers
ERIC Educational Resources Information Center
Nolan, Susan A.; Pace, Kristi A.; Iannelli, Richard J.; Palma, Thomas V.; Pakalns, Gail P.
2006-01-01
The authors describe a simple, cost-effective, and empirically supported program to increase faculty referrals of students to counseling centers (CCs). Incoming faculty members at 3 universities received a mailing and personal telephone call from a CC staff member. Faculty assigned to the outreach program had greater knowledge of and rates of…
DOE Office of Scientific and Technical Information (OSTI.GOV)
High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiencymore » water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less
Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schoenbauer, Ben
High-performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency watermore » heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less
Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schoenbauer, Ben
High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiencymore » water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less
Reducing the healthcare costs of urban air pollution: the South African experience.
Leiman, Anthony; Standish, Barry; Boting, Antony; van Zyl, Hugo
2007-07-01
Air pollutants often have adverse effects on human health. This paper investigates and ranks a set of policy and technological interventions intended to reduce such health costs in the high population density areas of South Africa. It initially uses a simple benefit-cost rule, later extended to capture sectoral employment impacts. Although the focus of state air quality legislation is on industrial pollutants, the most efficient interventions were found to be at household level. These included such low-cost interventions as training householders to place kindling above rather than below the coal in a fireplace and insulating roofs. The first non-household policies to emerge involved vehicle fuels and technologies. Most proposed industrial interventions failed a simple cost-benefit test. The paper's policy messages are that interventions should begin with households and that further industry controls are not yet justifiable in their present forms as these relate to the health care costs of such interventions.
Dykes, Patricia C; Wantland, Dean; Whittenburg, Luann; Lipsitz, Stuart; Saba, Virginia K
2013-01-01
While nursing activities represent a significant proportion of inpatient care, there are no reliable methods for determining nursing costs based on the actual services provided by the nursing staff. Capture of data to support accurate measurement and reporting on the cost of nursing services is fundamental to effective resource utilization. Adopting standard terminologies that support tracking both the quality and the cost of care could reduce the data entry burden on direct care providers. This pilot study evaluated the feasibility of using a standardized nursing terminology, the Clinical Care Classification System (CCC), for developing a reliable costing method for nursing services. Two different approaches are explored; the Relative Value Unit RVU and the simple cost-to-time methods. We found that the simple cost-to-time method was more accurate and more transparent in its derivation than the RVU method and may support a more consistent and reliable approach for costing nursing services.
Zurovac, Dejan; Larson, Bruce A; Sudoi, Raymond K; Snow, Robert W
2012-01-01
Simple interventions for improving health workers' adherence to malaria case-management guidelines are urgently required across Africa. A recent trial in Kenya showed that text-message reminders sent to health workers' mobile phones improved management of pediatric outpatients by 25 percentage points. In this paper we examine costs and cost-effectiveness of this intervention. We evaluate costs and cost-effectiveness in 2010 USD under three implementation scenarios: (1) as implemented under study conditions in study areas; (2) if the intervention was routinely implemented by the Ministry of Health (MoH) in the same areas; and (3) if the intervention was scaled up nationally. Under study conditions, intervention costs were 19,342 USD, of which 45% were for developing and pretesting text-messages, 12% for developing text-message distribution system, 29% for collecting health workers' phone numbers, and 13% were costs of sending text-messages and monitoring of the system. If the intervention was implemented in the same areas by the MoH, the costs would be 28% lower (13,920 USD) due to lower costs of collecting health workers' numbers. The cost of national scale-up would be 97,350 USD, and the majority of these costs (66%) would be for sending text-messages. The cost per additional child correctly managed was 0.50 USD under study conditions, 0.36 USD if implemented by the MoH in the same area, and estimated at only 0.03 USD if implemented nationally. Even if the effect size was only 5% or the cost on the national scale was 400% higher than estimated, the cost per additional child correctly managed would be only 0.16 USD. A simple text-messaging intervention improving health worker adherence to malaria guidelines is effective and inexpensive. Further research is justified to optimize delivery of the intervention and expand targets beyond children and malaria disease.
Simple Elasticity Modeling and Failure Prediction for Composite Flexbeams
NASA Technical Reports Server (NTRS)
Makeev, Andrew; Armanios, Erian; OBrien, T. Kevin (Technical Monitor)
2001-01-01
A simple 2D boundary element analysis, suitable for developing cost effective models for tapered composite laminates, is presented. Constant stress and displacement elements are used. Closed-form fundamental solutions are derived. Numerical results are provided for several configurations to illustrate the accuracy of the model.
Simple, Low-Cost Data Collection Methods for Agricultural Field Studies.
ERIC Educational Resources Information Center
Koenig, Richard T.; Winger, Marlon; Kitchen, Boyd
2000-01-01
Summarizes relatively simple and inexpensive methods for collecting data from agricultural field studies. Describes methods involving on-farm testing, crop yield measurement, quality evaluations, weed control effectiveness, plant nutrient status, and other measures. Contains 29 references illustrating how these methods were used to conduct…
Foglia, Giovanni; Mistrangelo, Emanuela; Lijoi, Davide; Alessandri, Franco; Ragni, Nicola
2007-07-01
To analyse prospectively the effectiveness of a new simple, minimally invasive, and cost-effective technique for the treatment of female urinary stress incontinence: the transfascial vaginal tape (TFT). In a prospective study, we enrolled 45 women undergoing TFT with or without hysterectomy and/or another pelvic reconstructive procedure between 1st December 2003 and 31st December. TFT consists of a tension-free urethrosuspension using a sling located at the mid-urethral level and placed laterally in the endopelvic fascia previously perforated. Follow-up evaluations were established at 3 and 6 months and at 1 year after the operation. During each follow-up, women underwent cough stress test and they answered to the "Incontinence quality of life questionnaire" (I-QOL), to the Patient Global Impression of Severity (PGI-S) and of Improvement (PGI-I) questions. Thirty-nine patients (88.9%) had a follow-up examination 1 year after surgery. Of these, 30 (76.9%) were defined cured, 6 (15.4%) improved and 3 (7.7%) failed. TFT procedure can be considered a simple, safe and cost-effective procedure for the treatment of stress urinary incontinence and can be an alternative to tension-free vaginal tape or transobturator route for sub-urethral tape procedures.
10 CFR 436.23 - Estimated simple payback time.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...
10 CFR 436.23 - Estimated simple payback time.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...
10 CFR 436.23 - Estimated simple payback time.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...
10 CFR 436.23 - Estimated simple payback time.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...
10 CFR 436.23 - Estimated simple payback time.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...
Regeneration and reuse of iron catalyst for Fenton-like reactions.
Cao, Guo-min; Sheng, Mei; Niu, Wen-feng; Fei, Yu-lei; Li, Dong
2009-12-30
Fenton and Fenton-like reactions employed for oxidative treatment of a typical industrial wastewater generate a large amount of ferric hydroxide sludge which has to be properly disposed at a high cost. This paper presents a simple and cost-effective method for recovering the iron catalyst from the iron hydroxide sludge for oxidative treatment of industrial wastewaters. The sludge was dewatered, dried and baked at 350-400 degrees C for 20-30 min; the residual solids were dissolved in sulfuric acid to form the reusable catalyst for Fenton and Fenton-like reactions. The recovered catalyst was highly effective for the oxidative pretreatment of a fine chemical wastewater to improve its biodegradability; the resulting COD removal and BOD(5)/COD ratio of the treated stream remained nearly unchanged during the time period when the regenerated catalyst was reused six times. The simple and effective catalyst regeneration method will make Fenton and Fenton-like oxidation a more cost-effective wastewater treatment alternative.
Tyson, Adam L.; Hilton, Stephen T.; Andreae, Laura C.
2015-01-01
The cost of 3D printing has reduced dramatically over the last few years and is now within reach of many scientific laboratories. This work presents an example of how 3D printing can be applied to the development of custom laboratory equipment that is specifically adapted for use with the novel brain tissue clearing technique, CLARITY. A simple, freely available online software tool was used, along with consumer-grade equipment, to produce a brain slicing chamber and a combined antibody staining and imaging chamber. Using standard 3D printers we were able to produce research-grade parts in an iterative manner at a fraction of the cost of commercial equipment. 3D printing provides a reproducible, flexible, simple and cost-effective method for researchers to produce the equipment needed to quickly adopt new methods. PMID:25797056
Wang, Saina; Sheng, Feng; Pan, Yunhua; Xu, Feng; Wang, Zhichao; Cheng, Lei
2015-08-01
To compare the clinical efficacy on cervical spondylotic radiculopathy between the combined therapy of massage and magnetic-sticking at the auricular points and the simple massage therapy, and conduct the health economics evaluation. Seventy-two patients of cervical spondylotic radiculopathy were randomized into a combined therapy group, and a simple massage group, 36 cases in each one. Finally, 35 cases and 34 cases were met the inclusive criteria in the corresponding groups separately. In the combined therapy group, the massage therapy and the magnetic sticking therapy at auricular points were combined in the treatment. Massage therapy was mainly applied to Fengchi (GB 20), Jianjing (GB 21), Jianwaishu (SI 14), Jianyu (LI 15) and Quchi (LI 11). The main auricular points for magnetic sticking pressure were Jingzhui (AH13), Gan (On12) Shen (CO10), Shenmen (TF4), Pizhixia (AT4). In the simple massage group, the simple massage therapy was given, the massage parts and methods were the same as those in the combined therapy group. The treatment was given once every two days, three times a week, for 4 weeks totally. The cervical spondylosis effect scale and the simplified McGill pain questionnaire were adopted to observe the improvements in the clinical symptoms, clinical examination, daily life movement, superficial muscular pain in the neck and the health economics cost in the patients of the two groups. The effect was evaluated in the two groups. The effective rate and the clinical curative rate in the combined therapy group were better than those in the control group [100. 0% (35/35) vs 85. 3% (29/34), 42. 9% (15/35) vs 17. 6% (6/34), both P<0. 05]. The scores of the spontaneous symptoms, clinical examnation, daily life movement and superficialmuscular pain in the neck were improved apparently after treatment as compared with those before treatment in the patients of the two groups (all P<0. 001). In terms of the improvements in the spontaneous symptoms, clinical examination total scores and superficial muscular pain in the' neck were more significant in the combined therapy group as compared with those in the simple massage group (P<0. 05, P<0. 01, P<0. 001). The cost at the unit effect in the combined therapy group was lower than that in the simple massage group (P<0. 05). Compared with the simple massage therapy, the massage therapy combined with magnetic sticking therapy at auricular points achieves the better effect and lower cost in health economics.
ABC estimation of unit costs for emergency department services.
Holmes, R L; Schroeder, R E
1996-04-01
Rapid evolution of the health care industry forces managers to make cost-effective decisions. Typical hospital cost accounting systems do not provide emergency department managers with the information needed, but emergency department settings are so complex and dynamic as to make the more accurate activity-based costing (ABC) system prohibitively expensive. Through judicious use of the available traditional cost accounting information and simple computer spreadsheets. managers may approximate the decision-guiding information that would result from the much more costly and time-consuming implementation of ABC.
Balloon logging with the inverted skyline
NASA Technical Reports Server (NTRS)
Mosher, C. F.
1975-01-01
There is a gap in aerial logging techniques that has to be filled. The need for a simple, safe, sizeable system has to be developed before aerial logging will become effective and accepted in the logging industry. This paper presents such a system designed on simple principles with realistic cost and ecological benefits.
Economics of internal and external energy storage in solar power plant operation
NASA Technical Reports Server (NTRS)
Manvi, R.; Fujita, T.
1977-01-01
A simple approach is formulated to investigate the effect of energy storage on the bus-bar electrical energy cost of solar thermal power plants. Economic analysis based on this approach does not require detailed definition of a specific storage system. A wide spectrum of storage system candidates ranging from hot water to superconducting magnets can be studied based on total investment and a rough knowledge of energy in and out efficiencies. Preliminary analysis indicates that internal energy storage (thermal) schemes offer better opportunities for energy cost reduction than external energy storage (nonthermal) schemes for solar applications. Based on data and assumptions used in JPL evaluation studies, differential energy costs due to storage are presented for a 100 MWe solar power plant by varying the energy capacity. The simple approach presented in this paper provides useful insight regarding the operation of energy storage in solar power plant applications, while also indicating a range of design parameters where storage can be cost effective.
ERIC Educational Resources Information Center
Young, Edmond W. K.; Simmons, Craig A.
2009-01-01
We describe a simple, low-cost laboratory session to demonstrate the Fahraeus-Lindqvist effect, a microphase flow phenomenon that occurs in small blood vessels and alters the effective rheological properties of blood. The experiments are performed by flowing cells through microchannels fabricated by soft lithography and characterization of cell…
A Cost-Effective Atomic Force Microscope for Undergraduate Control Laboratories
ERIC Educational Resources Information Center
Jones, C. N.; Goncalves, J.
2010-01-01
This paper presents a simple, cost-effective and robust atomic force microscope (AFM), which has been purposely designed and built for use as a teaching aid in undergraduate controls labs. The guiding design principle is to have all components be open and visible to the students, so the inner functioning of the microscope has been made clear to…
Chen, Ingrid T; Aung, Tin; Thant, Hnin Nwe Nwe; Sudhinaraset, May; Kahn, James G
2015-02-05
The emergence of artemisinin-resistant Plasmodium falciparum parasites in Southeast Asia threatens global malaria control efforts. One strategy to counter this problem is a subsidy of malaria rapid diagnostic tests (RDTs) and artemisinin-based combination therapy (ACT) within the informal private sector, where the majority of malaria care in Myanmar is provided. A study in Myanmar evaluated the effectiveness of financial incentives vs information, education and counselling (IEC) in driving the proper use of subsidized malaria RDTs among informal private providers. This cost-effectiveness analysis compares intervention options. A decision tree was constructed in a spreadsheet to estimate the incremental cost-effectiveness ratios (ICERs) among four strategies: no intervention, simple subsidy, subsidy with financial incentives, and subsidy with IEC. Model inputs included programmatic costs (in dollars), malaria epidemiology and observed study outcomes. Data sources included expenditure records, study data and scientific literature. Model outcomes included the proportion of properly and improperly treated individuals with and without P. falciparum malaria, and associated disability-adjusted life years (DALYs). Results are reported as ICERs in US dollars per DALY averted. One-way sensitivity analysis assessed how outcomes depend on uncertainty in inputs. ICERs from the least to most expensive intervention are: $1,169/DALY averted for simple subsidy vs no intervention, $185/DALY averted for subsidy with financial incentives vs simple subsidy, and $200/DALY averted for a subsidy with IEC vs subsidy with financial incentives. Due to decreasing ICERs, each strategy was also compared to no intervention. The subsidy with IEC was the most favourable, costing $639/DALY averted compared with no intervention. One-way sensitivity analysis shows that ICERs are most affected by programme costs, RDT uptake, treatment-seeking behaviour, and the prevalence and virulence of non-malarial fevers. In conclusion, private provider subsidies with IEC or a combination of IEC and financial incentives may be a good investment for malaria control.
Kim, Jeong Hun; Hwang, Ji-Young; Hwang, Ha Ryeon; Kim, Han Seop; Lee, Joong Hoon; Seo, Jae-Won; Shin, Ueon Sang; Lee, Sang-Hoon
2018-01-22
The development of various flexible and stretchable materials has attracted interest for promising applications in biomedical engineering and electronics industries. This interest in wearable electronics, stretchable circuits, and flexible displays has created a demand for stable, easily manufactured, and cheap materials. However, the construction of flexible and elastic electronics, on which commercial electronic components can be mounted through simple and cost-effective processing, remains challenging. We have developed a nanocomposite of carbon nanotubes (CNTs) and polydimethylsiloxane (PDMS) elastomer. To achieve uniform distributions of CNTs within the polymer, an optimized dispersion process was developed using isopropyl alcohol (IPA) and methyl-terminated PDMS in combination with ultrasonication. After vaporizing the IPA, various shapes and sizes can be easily created with the nanocomposite, depending on the mold. The material provides high flexibility, elasticity, and electrical conductivity without requiring a sandwich structure. It is also biocompatible and mechanically stable, as demonstrated by cytotoxicity assays and cyclic strain tests (over 10,000 times). We demonstrate the potential for the healthcare field through strain sensor, flexible electric circuits, and biopotential measurements such as EEG, ECG, and EMG. This simple and cost-effective fabrication method for CNT/PDMS composites provides a promising process and material for various applications of wearable electronics.
A Low Cost Course Information Syndication System
ERIC Educational Resources Information Center
Ajayi, A. O.; Olajubu, E. A.; Bello, S. A.; Soriyan, H. A.; Obamuyide, A. V.
2011-01-01
This study presents a cost effective, reliable, and convenient mobile web-based system to facilitate the dissemination of course information to students, to support interaction that goes beyond the classroom. The system employed the Really Simple Syndication (RSS) technology and was developed using Rapid Application Development (RAD) methodology.…
A simple technique of laparoscopic port closure.
Aziz, Homayara Haque
2013-01-01
Laparoscopic and robotic surgery is widely practiced in modern medicine. The operative procedure is not complete until the port sites are closed with a fascial suture. We report a simple new technique that is easy, cost-effective, and quick to apply using 2 S-retractors for suture placement under direct visualization to secure the abdominal wall fascia and peritoneum. As a prospective consecutive case series, this technique was used for fascial closure after laparoscopy ports > 8 mm using 2 S-retractors. One S-retractor is used as a barrier protecting the contents of the abdominal cavity, reducing the risk of visceral injuries. The second S-retractor allows us to directly visualize the different layers, exposing the needle tip during its course through the fascia. This method was used in 100 patients with no intraoperative incidents, additional operative time, or need to access costly instruments. Currently, this technique is also used by many surgeons in our institution without any difficulty. No bowel injuries or port-site hernias were reported during a mean follow-up of 6 wk postoperation and 12-mo annual follow-up. The procedure is simple, easy, cost-effective, and quick to apply.
How to prevent trachoma and blindness.
1995-01-01
The etiology associated with the loss of vision due to trachoma has been studied in great detail; so much so, that this cause of human suffering and potential blindness is now considered preventable. This brief communication describes the issues of trachoma prevention, available treatment, cost of prevention, and implementation challenges to establishing a program and making it work. International organizations such as WHO and UNICEF, in collaboration with nongovernmental organizations (NGOs) and local and national governments, have designed a simple yet effective trachoma control program. At the center of the program is community involvement. Better sanitation and access to clean water are two important community issues. Health education from childhood to adulthood is also critical. Individual knowledge about this disease has direct self-care implications (e.g., increased face washing). Treatment consists of antibiotics or simple surgery. Both have been developed to be low-cost and effective. National health officials must determine where health care funds are to be spent. This trachoma control program should be considered cost-effective. Materials and training are available for program implementation. Cost need no longer be the limiting factor in the establishment of a trachoma prevention and control program.
A Simple "in Vitro" Culture of Freshwater Prawn Embryos for Laboratory Investigations
ERIC Educational Resources Information Center
Porntrai, Supaporn; Damrongphol, Praneet
2008-01-01
Giant freshwater prawn ("Macrobrachium rosenbergii" De Man) embryos can be cultured "in vitro" to hatching in 15% (v/v) artificial seawater (ASW). This technique can be applied as a bioassay for testing toxicity or for the effects of various substances on embryo development and can be used as a simple and low-cost model for…
Levelized Cost of Energy Calculator | Energy Analysis | NREL
Levelized Cost of Energy Calculator Levelized Cost of Energy Calculator Transparent Cost Database Button The levelized cost of energy (LCOE) calculator provides a simple calculator for both utility-scale need to be included for a thorough analysis. To estimate simple cost of energy, use the slider controls
Niarchos, Georgios; Dubourg, Georges; Afroudakis, Georgios; Georgopoulos, Markos; Tsouti, Vasiliki; Makarona, Eleni; Crnojevic-Bengin, Vesna; Tsamis, Christos
2017-01-01
In this paper, we investigated the effect of humidity on paper substrates and propose a simple and low-cost method for their passivation using ZnO nanoparticles. To this end, we built paper-based microdevices based on an interdigitated electrode (IDE) configuration by means of a mask-less laser patterning method on simple commercial printing papers. Initial resistive measurements indicate that a paper substrate with a porous surface can be used as a cost-effective, sensitive and disposable humidity sensor in the 20% to 70% relative humidity (RH) range. Successive spin-coated layers of ZnO nanoparticles then, control the effect of humidity. Using this approach, the sensors become passive to relative humidity changes, paving the way to the development of ZnO-based gas sensors on paper substrates insensitive to humidity. PMID:28273847
Market frictions: A unified model of search costs and switching costs
Wilson, Chris M.
2012-01-01
It is well known that search costs and switching costs can create market power by constraining the ability of consumers to change suppliers. While previous research has examined each cost in isolation, this paper demonstrates the benefits of examining the two types of friction in unison. The paper shows how subtle distinctions between the two costs can provide important differences in their effects upon consumer behaviour, competition and welfare. In addition, the paper also illustrates a simple empirical methodology for estimating separate measures of both costs, while demonstrating a potential bias that can arise if only one cost is considered. PMID:25550674
Opportunity Cost: A Reexamination
ERIC Educational Resources Information Center
Parkin, Michael
2016-01-01
Is opportunity cost an ambiguous and arbitrary concept or a simple, straightforward, and fruitful one? This reexamination of opportunity cost addresses this question, and shows that opportunity cost is an ambiguous concept because "two" definitions are in widespread use. One of the definitions is indeed simple, fruitful, and one that…
Simple Remodeling for Tomorrow's Needs: Cost-Effective Green Solutions for Your Home
ERIC Educational Resources Information Center
Purpora, Megan
2009-01-01
People normally do not think about the future of their home in terms of accessibility. But, since Americans spend approximately 90 percent of their time indoors, shouldn't their home be as accessible as possible? By doing a few simple home upgrades on overlooked items, it will lessen the burden later. To live safer and healthier use natural…
Results of FM-TV threshold reduction investigation for the ATS F trust experiment
NASA Technical Reports Server (NTRS)
Brown, J. P.
1972-01-01
An investigation of threshold effects in FM TV was initiated to determine if any simple, low cost techniques were available which can reduce the subjective video threshold, applicable to low cost community TV reception via satellite. Two methods of eliminating these effects were examined: the use of standard video pre-emphasis, and the use of an additional circuit to blank the picture tube during the retrace period.
Simple and cost-effective fluorescent labeling of 5-hydroxymethylcytosine
NASA Astrophysics Data System (ADS)
Shahal, Tamar; Green, Ori; Hananel, Uri; Michaeli, Yael; Shabat, Doron; Ebenstein, Yuval
2016-12-01
The nucleobase 5-hydroxymethylcytosine (5-hmC), a modified form of cytosine, is an important epigenetic mark related to regulation of gene expression. 5-hmC levels are highly dynamic during early development and are modulated during the progression of neurodegenerative disease and cancer. We describe a spectroscopic method for the global quantification of 5-hmC in genomic DNA. This method relies on the enzymatic glucosylation of 5-hmC, followed by a glucose oxidation step that results in the formation of aldehyde moieties that are covalently linked to a fluorescent reporter by oxime ligation. The fluorescence intensity of the labeled sample is directly proportional to its 5-hmC content. We show that this simple and cost-effective technique is suitable for quantification of 5-hmC content in different mouse tissues.
ERIC Educational Resources Information Center
Norris, Robert G.
A cost-effectiveness model is presented for academic administrators to use in making evaluation and planning decisions related directly to the instructional activities of academic departments. The advantages seen in the model are that it is simple and flexible, concentrates on balancing income generated by the department to expenses incurred, and…
Increased uniformity by planting clones will likely have a minimal effect on inventory costs
Curtis L. VanderSchaaf; Dean W. Coble; David B. South
2012-01-01
When conducting inventories, reducing variability among tree diameters, heights, and ultimately volumes or biomass, can reduce the number of points/plots needed to obtain a desired level of precision. We present a simple analysis examining the potential reduction in discounted inventory costs when stand variability is decreased (via improved genetics and intensive...
Airtightness the simple(CS) way
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andrews, S.
Builders who might buck against such time consuming air sealing methods as polyethylene wrap and the airtight drywall approach (ADA) may respond better to current strategies. One such method, called SimpleCS, has proven especially effective. SimpleCS, pronounced simplex, stands for simple caulk and seal. A modification of the ADA, SimpleCS is an air-sealing management tool, a simplified systems approach to building tight homes. The system address the crucial question of when and by whom various air sealing steps should be done. It avoids the problems that often occur when later contractors cut open polyethylene wrap to drill holes in themore » drywall. The author describes how SimpleCS works, and the cost and training involved.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dewani, Aliya A., E-mail: a.ashraf@griffith.edu.au; O’Keefe, Steven G.; Thiel, David V.
A novel 2D simple low cost frequency selective surface was screen printed on thin (0.21 mm), flexible transparent plastic substrate (relative permittivity 3.2). It was designed, fabricated and tested in the frequency range 10-20 GHz. The plane wave transmission and reflection coefficients agreed with numerical modelling. The effective permittivity and thickness of the backing sheet has a significant effect on the frequency characteristics. The stop band frequency reduced from 15GHz (no backing) to 12.5GHz with polycarbonate. The plastic substrate thickness beyond 1.8mm has minimal effect on the resonant frequency. While the inner element spacing controls the stop-band frequency, the substratemore » thickness controls the bandwidth. The screen printing technique provided a simple, low cost FSS fabrication method to produce flexible, conformal, optically transparent and bio-degradable FSS structures which can find their use in electromagnetic shielding and filtering applications in radomes, reflector antennas, beam splitters and polarizers.« less
Optically transparent frequency selective surfaces on flexible thin plastic substrates
NASA Astrophysics Data System (ADS)
Dewani, Aliya A.; O'Keefe, Steven G.; Thiel, David V.; Galehdar, Amir
2015-02-01
A novel 2D simple low cost frequency selective surface was screen printed on thin (0.21 mm), flexible transparent plastic substrate (relative permittivity 3.2). It was designed, fabricated and tested in the frequency range 10-20 GHz. The plane wave transmission and reflection coefficients agreed with numerical modelling. The effective permittivity and thickness of the backing sheet has a significant effect on the frequency characteristics. The stop band frequency reduced from 15GHz (no backing) to 12.5GHz with polycarbonate. The plastic substrate thickness beyond 1.8mm has minimal effect on the resonant frequency. While the inner element spacing controls the stop-band frequency, the substrate thickness controls the bandwidth. The screen printing technique provided a simple, low cost FSS fabrication method to produce flexible, conformal, optically transparent and bio-degradable FSS structures which can find their use in electromagnetic shielding and filtering applications in radomes, reflector antennas, beam splitters and polarizers.
Bae, Myungsoo; Lee, Sangmin; Kim, Namkug
2018-07-01
To develop and validate a robust and cost-effective 3D respiratory monitoring system based on a Kinect device with a custom-made simple marker. A 3D respiratory monitoring system comprising the simple marker and the Microsoft Kinect v2 device was developed. The marker was designed for simple and robust detection, and the tracking algorithm was developed using the depth, RGB, and infra-red images acquired from the Kinect sensor. A Kalman filter was used to suppress movement noises. The major movements of the marker attached to the four different locations of body surface were determined from the initially collected tracking points of the marker while breathing. The signal level of respiratory motion with the tracking point was estimated along the major direction vector. The accuracy of the results was evaluated through a comparison with those of the conventional stereovision navigation system (NDI Polaris Spectra). Sixteen normal volunteers were enrolled to evaluate the accuracy of this system. The correlation coefficients between the respiratory motion signal from the Kinect device and conventional navigation system ranged from 0.970 to 0.999 and from 0.837 to 0.995 at the abdominal and thoracic surfaces, respectively. The respiratory motion signal from this system was obtained at 27-30 frames/s. This system with the Kinect v2 device and simple marker could be used for cost-effective, robust and accurate 3D respiratory motion monitoring. In addition, this system is as reliable for respiratory motion signal generation and as practically useful as the conventional stereovision navigation system and is less sensitive to patient posture. Copyright © 2018 Elsevier B.V. All rights reserved.
Nema, Shubham; Hasan, Whidul; Bhargava, Anamika; Bhargava, Yogesh
2016-09-15
Behavioural neuroscience relies on software driven methods for behavioural assessment, but the field lacks cost-effective, robust, open source software for behavioural analysis. Here we propose a novel method which we called as ZebraTrack. It includes cost-effective imaging setup for distraction-free behavioural acquisition, automated tracking using open-source ImageJ software and workflow for extraction of behavioural endpoints. Our ImageJ algorithm is capable of providing control to users at key steps while maintaining automation in tracking without the need for the installation of external plugins. We have validated this method by testing novelty induced anxiety behaviour in adult zebrafish. Our results, in agreement with established findings, showed that during state-anxiety, zebrafish showed reduced distance travelled, increased thigmotaxis and freezing events. Furthermore, we proposed a method to represent both spatial and temporal distribution of choice-based behaviour which is currently not possible to represent using simple videograms. ZebraTrack method is simple and economical, yet robust enough to give results comparable with those obtained from costly proprietary software like Ethovision XT. We have developed and validated a novel cost-effective method for behavioural analysis of adult zebrafish using open-source ImageJ software. Copyright © 2016 Elsevier B.V. All rights reserved.
Palmer, Keith T; Harris, Elizabeth C; Linaker, Cathy; Barker, Mary; Lawrence, Wendy; Cooper, Cyrus; Coggon, David
2012-02-01
To assess the effectiveness of interventions in community and workplace settings to reduce sickness absence and job loss in workers with musculoskeletal disorders (MSDs). Relevant randomized controlled trials (RCTs) and cohort studies, published since 1990, were identified by screening citations from 35 earlier systematic reviews and by searching MEDLINE and Embase until April 2010. Effects were estimated by intervention category and other features, including study quality. Among 42 studies (including 34 RCTs), 27 assessed return to work (RTW), 21 duration of sickness absence and 5 job loss. Interventions included exercise therapy, behavioural change techniques, workplace adaptations and provision of additional services. Studies were typically small {median sample 107 [inter-quartile range (IQR) 77-148]} and limited in quality. Most interventions appeared beneficial: the median relative risk (RR) for RTW was 1.21 (IQR 1.00-1.60) and that for avoiding MSD-related job loss was 1.25 (IQR 1.06-1.71); the median reduction in sickness absence was 1.11 (IQR 0.32-3.20) days/month. However, effects were smaller in larger and better-quality studies, suggesting publication bias. No intervention was clearly superior, although effort-intensive interventions were less effective than simple ones. No cost-benefit analyses established statistically significant net economic benefits. As benefits are small and of doubtful cost-effectiveness, employers' practice should be guided by their value judgements about the uncertainties. Expensive interventions should be implemented only with rigorous cost-benefit evaluation planned from the outset. Future research should focus on the cost-effectiveness of simple, low-cost interventions, and further explore impacts on job retention.
USDA-ARS?s Scientific Manuscript database
Although Campylobacter is an important food-borne human pathogen, there remains a lack of molecular diagnostic assays that are simple to use, cost-effective, and provide rapid results in research, clinical, or regulatory laboratories. Of the numerous Campylobacter assays that do exist, to our knowl...
Understanding the essentials of economic evaluation.
Schmid, G P
1995-01-01
Economic evaluation (EE) answers the following simple question: "From which course of action do we get the most value for our money?" We ask this question because resources are always limited, i.e., we never have enough money to do all the things we would like to do. Three types of economic evaluations are used: cost-effectiveness analysis, cost-utility analysis, and cost-benefit analysis. Although all involve a monetary and outcome comparison of two or more courses of action, the methodologies and outcomes of each type vary, making each one particularly suited for specific and different indications. Although the performance of an EE may be complex, its concept is intuitively simple. Understanding the basic elements of economic analysis is more and more important to all health-care providers because health-care policy makers at all levels are increasingly using EE for allocating resources.
Nitrogen in the Baltic Sea--policy implications of stock effects.
Hart, Rob; Brady, Mark
2002-09-01
We develop an optimal control model for cost-effective management of pollution, including two state variables, pollution stock and ecosystem quality. We apply it to Baltic Sea pollution by nitrogen leachates from agriculture. We present a sophisticated, non-linear model of leaching abatement costs, and a simple model of nitrogen stocks. We find that significant abatement is achievable at reasonable cost, despite the countervailing effects of existing agricultural policies such as price supports. Successful abatement should lead to lower nitrogen stocks in the sea in 5 years or less. However, the rate of ecosystem recovery is less certain. The results are highly dependent on the rate of self-cleaning of the Baltic Sea, and less so on the discount rate. Choice of target has a radical effect on the abatement path chosen. Cost-effectiveness demands such a choice, and should therefore be used with care when stock effects are present.
Biomarker detection for disease diagnosis using cost-effective microfluidic platforms.
Sanjay, Sharma T; Fu, Guanglei; Dou, Maowei; Xu, Feng; Liu, Rutao; Qi, Hao; Li, XiuJun
2015-11-07
Early and timely detection of disease biomarkers can prevent the spread of infectious diseases, and drastically decrease the death rate of people suffering from different diseases such as cancer and infectious diseases. Because conventional diagnostic methods have limited application in low-resource settings due to the use of bulky and expensive instrumentation, simple and low-cost point-of-care diagnostic devices for timely and early biomarker diagnosis is the need of the hour, especially in rural areas and developing nations. The microfluidics technology possesses remarkable features for simple, low-cost, and rapid disease diagnosis. There have been significant advances in the development of microfluidic platforms for biomarker detection of diseases. This article reviews recent advances in biomarker detection using cost-effective microfluidic devices for disease diagnosis, with the emphasis on infectious disease and cancer diagnosis in low-resource settings. This review first introduces different microfluidic platforms (e.g. polymer and paper-based microfluidics) used for disease diagnosis, with a brief description of their common fabrication techniques. Then, it highlights various detection strategies for disease biomarker detection using microfluidic platforms, including colorimetric, fluorescence, chemiluminescence, electrochemiluminescence (ECL), and electrochemical detection. Finally, it discusses the current limitations of microfluidic devices for disease biomarker detection and future prospects.
A convenient Simple Method for Synthesis of Meta-iodobenzylguanidine (MIBG).
Sheikholislam, Zahra; Soleimani, Zohreh; Moghimi, Abolghasem; Shahhosseini, Soraya
2013-01-01
Radioiodinated meta-iodobenzylguanidine (MIBG) is one of the important radiopharmaceuticals in Nuclear Medicine. [(123/131)I] MIBG is used for imaging of Adrenal medulla, studying heart sympathetic nerves, treatment of pheochromacytoma and neuroblastoma. For clinical application, radioiodinated MIBG is prepared through isotopic exchange method, which includes replacement of radioactive iodine in a nucleophilic substitution reaction with cold iodine ((127)I). The unlabelled MIBG hemisulfate is synthesized by the procedure described by Wieland et al. (1980). The availability of a more practical and cost-effective procedure for MIBG preparation encouraged us to study the MIBG synthesis methods. In this study the preparation of MIBG through different methods were evaluated and a new method, which is one step, simple and cost-effective is introduced. The method has ability to be scaled up for production of unlabelled MIBG.
Palmer, Keith T; Harris, Clare; Linaker, Cathy; Barker, Mary; Lawrence, Wendy; Cooper, Cyrus; Coggon, David
2012-01-01
This systematic review assesses the effectiveness of interventions in community and workplace settings to reduce sickness absence and job loss in workers with musculoskeletal disorders (MSDs). Relevant studies (randomised controlled trials (RCTs) and cohort studies published since 1990) were identified by screening citations in 35 earlier systematic reviews and from searches of Medline and Embase to April 2010. Among 42 studies (54 reports) including 34 RCTs, 27 assessed return to work, 21 duration of sickness absence, and five job loss. Interventions included exercise therapy, behavioural change techniques, workplace adaptations and provision of additional services. Studies were typically small (median sample size 107 (inter-quartile range (IQR) 77 to 148) and limited in quality. Most interventions were reported as beneficial: the median relative risk (RR) for return to work was 1.21 (IQR 1.00 – 1.60) and that for avoiding MSD-related job loss, 1.25 (IQR 1.06-1.71); the median reduction in sickness absence was 1.11 (IQR 0.32 to 3.20) days/month. However, effects were smaller in the larger and better quality studies, suggesting publication bias. No intervention was clearly superior to others, although effort-intensive interventions were less effective than simple ones. No cost-benefit analyses established statistically significant net economic benefits. Given that benefits are small and of doubtful cost-effectiveness, employers’ practice should be guided by their value judgements about the uncertainties. Expensive interventions should be implemented only with rigorous cost-benefit evaluation planned from the outset. Future research should focus on the cost-effectiveness of simple low cost interventions, and further explore impacts on job retention. PMID:21415023
Cost effective patient location monitoring system using webcams.
Logeswaran, Rajasvaran
2009-10-01
This paper details the development of a simple webcam joystick, a wireless, or rather cableless, and contactless pointing device by using a webcam and a simple flexible non-electronic joystick. Such a system requires no power source on the joystick, allows for light, robust and very mobile joysticks, and can be extended into a large array of applications. This paper proposes the use of small webcam joysticks as sensors for recording movement, the way wireless sensors are used. Specifically, it could be used as a simple navigation and monitoring system for patient movement in medical wards, where knowledge of patient location and movement could provide instant assistance, pre-emptive action and also hinder untoward patient mix-ups. Experiments and discussions in this paper highlight how a successful implementation is possible, and emphasize the flexibility of such an implementation in a low cost medical environment.
The acquisition of simple associations as observed in color-word contingency learning.
Lin, Olivia Y-H; MacLeod, Colin M
2018-01-01
Three experiments investigated the learning of simple associations in a color-word contingency task. Participants responded manually to the print colors of 3 words, with each word associated strongly to 1 of the 3 colors and weakly to the other 2 colors. Despite the words being irrelevant, response times to high-contingency stimuli and to low-contingency stimuli quickly diverged. This high-low difference remained quite constant over successive blocks of trials, evidence of stable contingency learning. Inclusion of a baseline condition-an item having no color-word contingency-permitted separation of the contingency learning effect into 2 components: a cost due to low contingency and a benefit due to high contingency. Both cost and benefit were quick to acquire, quick to extinguish, and quick to reacquire. The color-word contingency task provides a simple way to directly study the learning of associations. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
[Cost-effectiveness analysis and diet quality index applied to the WHO Global Strategy].
Machado, Flávia Mori Sarti; Simões, Arlete Naresse
2008-02-01
To test the use of cost-effectiveness analysis as a decision making tool in the production of meals for the inclusion of the recommendations published in the World Health Organization's Global Strategy. Five alternative options for breakfast menu were assessed previously to their adoption in a food service at a university in the state of Sao Paulo, Southeastern Brazil, in 2006. Costs of the different options were based on market prices of food items (direct cost). Health benefits were estimated based on adaptation of the Diet Quality Index (DQI). Cost-effectiveness ratios were estimated by dividing benefits by costs and incremental cost-effectiveness ratios were estimated as cost differential per unit of additional benefit. The meal choice was based on health benefit units associated to direct production cost as well as incremental effectiveness per unit of differential cost. The analysis showed the most simple option with the addition of a fruit (DQI = 64 / cost = R$ 1.58) as the best alternative. Higher effectiveness was seen in the options with a fruit portion (DQI1=64 / DQI3=58 / DQI5=72) compared to the others (DQI2=48 / DQI4=58). The estimate of cost-effectiveness ratio allowed to identifying the best breakfast option based on cost-effectiveness analysis and Diet Quality Index. These instruments allow easy application easiness and objective evaluation which are key to the process of inclusion of public or private institutions under the Global Strategy directives.
Low-Cost Detection of Thin Film Stress during Fabrication
NASA Technical Reports Server (NTRS)
Nabors, Sammy A.
2015-01-01
NASA's Marshall Space Flight Center has developed a simple, cost-effective optical method for thin film stress measurements during growth and/or subsequent annealing processes. Stress arising in thin film fabrication presents production challenges for electronic devices, sensors, and optical coatings; it can lead to substrate distortion and deformation, impacting the performance of thin film products. NASA's technique measures in-situ stress using a simple, noncontact fiber optic probe in the thin film vacuum deposition chamber. This enables real-time monitoring of stress during the fabrication process and allows for efficient control of deposition process parameters. By modifying process parameters in real time during fabrication, thin film stress can be optimized or controlled, improving thin film product performance.
JJ Stent Removal under Ultrasound Guidance in Women: It is Simple and Safe.
Amer, Bernard; Gupta, Sandeep; Kanwar, Vijayendra S; Lodh, Bijit; Khumukcham, Somarendra; Akoijam, Kaku Singh
2014-12-01
With the increase in number of patients treated for urological problems with endoscopic procedures, the number of patients with JJ stent is also increasing. The amount of workload thus incurred multiplies, even to the point that, sometimes we waste more time in the operating room removing JJ stents than the actual endourological procedures. Here in our institute, we have devised a very simple and effective way of removing JJ stents in women and also determined the efficacy, safety and cost of JJ stent removal under ultrasound guidance in women in comparison to cystoscopic removal. Two hundred women attending the Department of Urology from July 2012 to July 2013 at RIMS hospital were randomly divided into two arms. One hundred women had their JJ stent removed with cystoscope and another 100 women had their JJ stent removed under ultrasound guidance using simple surgical tools available at the hospital. The primary comparative points were waiting time for operating room appointment date, cost of the procedure, time taken for the procedure, discomfort or pain felt by the patient and urethral injuries. In all the parameters, stent removal under ultrasound guidance was significantly better except for urethral injuries where both the procedures had similar outcomes. We concluded that JJ stent removal under ultrasound guidance in women was simple, effective and safe.
Practical thoughts on cost-benefit analysis and health services.
Burchell, A; Weeden, R
1982-08-01
Cost-benefit analysis is fast becoming--if it is not already--an essential tool in decision making. It is, however, a complex subject, and one in which few doctors have been trained. This paper offers practical thoughts on the art of cost-benefit analysis, and is written for clinicians and other medical specialists who, though inexpert in the techniques of accountancy, nevertheless wish to carry out their own simple analyses in a manner that will enable them, and others, to take effective decisions.
External tissue expansion for difficult wounds using a simple cost effective technique.
Nandhagopal, Vijayaraghavan; Chittoria, Ravi Kumar; Mohapatra, Devi Prasad; Thiruvoth, Friji Meethale; Sivakumar, Dinesh Kumar; Ashokan, Arjun
2015-01-01
To study and discuss role of external tissue expansion and wound closure (ETEWC) technique using hooks and rubber bands. The present study is a retrospective analysis of nine cases of wounds of different aetiology where ETEWC technique was applied using hooks and rubber bands. All the wounds in the study healed completely without split thickness skin graft (SSG) or flap. ETEWC technique using hooks and rubber bands is a cost-effective technique which can be used for wound closure without SSG or flap.
A Simple Low-Cost Lock-In Amplifier for the Laboratory
ERIC Educational Resources Information Center
Sengupta, Sandip K.; Farnham, Jessica M.; Whitten, James E.
2005-01-01
The creation of a simple, low-cost lock-in amplifier (LIA) suitable for use in the chemistry teaching laboratory is described. The use of integrated circuits and few components are necessary to adequately accomplish lock-in amplification limited the total cost of construction to under US$100.
Low cost charged-coupled device (CCD) based detectors for Shiga toxins activity analysis
USDA-ARS?s Scientific Manuscript database
To improve food safety there is a need to develop simple, low-cost sensitive devices for detection of foodborne pathogens and their toxins. We describe a simple and relatively low-cost webcam-based detector which can be used for various optical detection modalities, including fluorescence, chemilumi...
Déglon, Julien; Versace, François; Lauer, Estelle; Widmer, Christèle; Mangin, Patrice; Thomas, Aurélien; Staub, Christian
2012-06-01
Dried blood spots (DBS) sampling has gained popularity in the bioanalytical community as an alternative to conventional plasma sampling, as it provides numerous benefits in terms of sample collection and logistics. The aim of this work was to show that these advantages can be coupled with a simple and cost-effective sample pretreatment, with subsequent rapid LC-MS/MS analysis for quantitation of 15 benzodiazepines, six metabolites and three Z-drugs. For this purpose, a simplified offline procedure was developed that consisted of letting a 5-µl DBS infuse directly into 100 µl of MeOH, in a conventional LC vial. The parameters related to the DBS pretreatment, such as extraction time or internal standard addition, were investigated and optimized, demonstrating that passive infusion in a regular LC vial was sufficient to quantitatively extract the analytes of interest. The method was validated according to international criteria in the therapeutic concentration ranges of the selected compounds. The presented strategy proved to be efficient for the rapid analysis of the selected drugs. Indeed, the offline sample preparation was reduced to a minimum, using a small amount of organic solvent and consumables, without affecting the accuracy of the method. Thus, this approach enables simple and rapid DBS analysis, even when using a non-DBS-dedicated autosampler, while lowering the costs and environmental impact.
Modular experimental platform for science and applications
NASA Technical Reports Server (NTRS)
Hill, A. S.
1984-01-01
A modularized, standardized spacecraft bus, known as MESA, suitable for a variety of science and applications missions is discussed. The basic bus consists of a simple structural arrangement housing attitude control, telemetry/command, electrical power, propulsion and thermal control subsystems. The general arrangement allows extensive subsystem adaptation to mission needs. Kits provide for the addition of tape recorders, increased power levels and propulsion growth. Both 3-axis and spin stabilized flight proven attitude control subsystems are available. The MESA bus can be launched on Ariane, as a secondary payload for low cost, or on the STS with a PAM-D or other suitable upper stage. Multi-spacecraft launches are possible with either booster. Launch vehicle integration is simple and cost-effective. The low cost of the MESA bus is achieved by the extensive utilization of existing subsystem design concepts and equipment, and efficient program management and test integration techniques.
Application of a low cost ceramic filter to a membrane bioreactor for greywater treatment.
Hasan, Md Mahmudul; Shafiquzzaman, Md; Nakajima, Jun; Ahmed, Abdel Kader T; Azam, Mohammad Shafiul
2015-03-01
The performance of a low cost and simple ceramic filter to a membrane bioreactor (MBR) process was evaluated for greywater treatment. The ceramic filter was submerged in an acrylic cylindrical column bioreactor. Synthetic greywater (prepared by shampoo, dish cleaner and laundry detergent) was fed continuously into the reactor. The filter effluent was obtained by gravitational pressure. The average flux performance was observed to be 11.5 LMH with an average hydraulic retention time of 1.7 days. Complete biodegradation of surfactant (methylene blue active substance removal: 99-100%) as well as high organic removal performance (biochemical oxygen demand: 97-100% and total organic carbon: >88%) was obtained. The consistency of flux (11.5 LMH) indicated that the filter can be operated for a long time without fouling. The application of this simple ceramic filter would make MBR technology cost-effective in developing countries for greywater reclamation and reuse.
Strategies for Diagnosing and Treating Suspected Acute Bacterial Sinusitis
Balk, Ethan M; Zucker, Deborah R; Engels, Eric A; Wong, John B; Williams, John W; Lau, Joseph
2001-01-01
OBJECTIVE Symptoms suggestive of acute bacterial sinusitis are common. Available diagnostic and treatment options generate substantial costs with uncertain benefits. We assessed the cost-effectiveness of alternative management strategies to identify the optimal approach. DESIGN For such patients, we created a Markov model to examine four strategies: 1) no antibiotic treatment; 2) empirical antibiotic treatment; 3) clinical criteria-guided treatment; and 4) radiography-guided treatment. The model simulated a 14-day course of illness, included sinusitis prevalence, antibiotic side effects, sinusitis complications, direct and indirect costs, and symptom severity. Strategies costing less than $50,000 per quality-adjusted life year gained were considered “cost-effective.” MEASUREMENTS AND MAIN RESULTS For mild or moderate disease, basing antibiotic treatment on clinical criteria was cost-effective in clinical settings where sinusitis prevalence is within the range of 15% to 93% or 3% to 63%, respectively. For severe disease, or to prevent sinusitis or antibiotic side effect symptoms, use of clinical criteria was cost-effective in settings with lower prevalence (below 51% or 44%, respectively); empirical antibiotics was cost-effective with higher prevalence. Sinus radiography-guided treatment was never cost-effective for initial treatment. CONCLUSIONS Use of a simple set of clinical criteria to guide treatment is a cost-effective strategy in most clinical settings. Empirical antibiotics are cost-effective in certain settings; however, their use results in many unnecessary prescriptions. If this resulted in increased antibiotic resistance, costs would substantially rise and efficacy would fall. Newer, expensive antibiotics are of limited value. Additional testing is not cost-effective. Further studies are needed to find an accurate, low-cost diagnostic test for acute bacterial sinusitis. PMID:11679039
A Peltier-based variable temperature source
NASA Astrophysics Data System (ADS)
Molki, Arman; Roof Baba, Abdul
2014-11-01
In this paper we propose a simple and cost-effective variable temperature source based on the Peltier effect using a commercially purchased thermoelectric cooler. The proposed setup can be used to quickly establish relatively accurate dry temperature reference points, which are necessary for many temperature applications such as thermocouple calibration.
An Efficient, Noniterative Method of Identifying the Cost-Effectiveness Frontier.
Suen, Sze-chuan; Goldhaber-Fiebert, Jeremy D
2016-01-01
Cost-effectiveness analysis aims to identify treatments and policies that maximize benefits subject to resource constraints. However, the conventional process of identifying the efficient frontier (i.e., the set of potentially cost-effective options) can be algorithmically inefficient, especially when considering a policy problem with many alternative options or when performing an extensive suite of sensitivity analyses for which the efficient frontier must be found for each. Here, we describe an alternative one-pass algorithm that is conceptually simple, easier to implement, and potentially faster for situations that challenge the conventional approach. Our algorithm accomplishes this by exploiting the relationship between the net monetary benefit and the cost-effectiveness plane. To facilitate further evaluation and use of this approach, we also provide scripts in R and Matlab that implement our method and can be used to identify efficient frontiers for any decision problem. © The Author(s) 2015.
An Efficient, Non-iterative Method of Identifying the Cost-Effectiveness Frontier
Suen, Sze-chuan; Goldhaber-Fiebert, Jeremy D.
2015-01-01
Cost-effectiveness analysis aims to identify treatments and policies that maximize benefits subject to resource constraints. However, the conventional process of identifying the efficient frontier (i.e., the set of potentially cost-effective options) can be algorithmically inefficient, especially when considering a policy problem with many alternative options or when performing an extensive suite of sensitivity analyses for which the efficient frontier must be found for each. Here, we describe an alternative one-pass algorithm that is conceptually simple, easier to implement, and potentially faster for situations that challenge the conventional approach. Our algorithm accomplishes this by exploiting the relationship between the net monetary benefit and the cost-effectiveness plane. To facilitate further evaluation and use of this approach, we additionally provide scripts in R and Matlab that implement our method and can be used to identify efficient frontiers for any decision problem. PMID:25926282
Simple two-electrode biosignal amplifier.
Dobrev, D; Neycheva, T; Mudrov, N
2005-11-01
A simple, cost effective circuit for a two-electrode non-differential biopotential amplifier is proposed. It uses a 'virtual ground' transimpedance amplifier and a parallel RC network for input common mode current equalisation, while the signal input impedance preserves its high value. With this innovative interface circuit, a simple non-inverting amplifier fully emulates high CMRR differential. The amplifier equivalent CMRR (typical range from 70-100 dB) is equal to the open loop gain of the operational amplifier used in the transimpedance interface stage. The circuit has very simple structure and utilises a small number of popular components. The amplifier is intended for use in various two-electrode applications, such as Holter-type monitors, defibrillators, ECG monitors, biotelemetry devices etc.
NASA Astrophysics Data System (ADS)
Samuel, R.; Thacker, C. M.; Maricq, A. V.; Gale, B. K.
2014-09-01
We present a new fabrication protocol for fabricating pneumatically controlled microvalve arrays (consisting of 100 s of microvalves) in PDMS substrates. The protocol utilizes rapid and cost-effective fabrication of molds using laser cutting of adhesive vinyl tapes and replica molding of PDMS. Hence the protocol is fast, simple and avoids cleanroom use. The results show that effective doormat-style microvalves can be easily fabricated in arrays by manipulating the stiffness of the actuating membrane through varying the valve-chamber area/shape. Three frequently used valve-chamber shapes (circle, square and capsule) were tested and all showed advantages in different situations. Circular valve chambers were best for small valves, square valves were best for medium-sized valves, and the capsule valves were best for larger valves. An application of this protocol has been demonstrated in the fabrication of a microfluidic 32-well plate for high-throughput manipulation of C. elegans for biomedical research.
A method for measuring sulfide toxicity in the nematode Caenorhabditis elegans.
Livshits, Leonid; Gross, Einav
2017-01-01
Cysteine catabolism by gut microbiota produces high levels of sulfide. Excessive sulfide can interfere with colon function, and therefore may be involved in the etiology and risk of relapse of ulcerative colitis, an inflammatory bowel disease affecting millions of people worldwide. Therefore, it is crucial to understand how cells/animals regulate the detoxification of sulfide generated by bacterial cysteine catabolism in the gut. Here we describe a simple and cost-effective way to explore the mechanism of sulfide toxicity in the nematode Caenorhabditis elegans ( C. elegans ). •A rapid cost-effective method to quantify and study sulfide tolerance in C. elegans and other free-living nematodes.•A cost effective method to measure the concentration of sulfide in the inverted plate assay.
Cost-effectiveness of strategies to enhance mammography use.
Fishman, P; Taplin, S; Meyer, D; Barlow, W
2000-01-01
To estimate the cost-effectiveness of three strategies to increase breast cancer screening with mammography (reminder postcard, reminder telephone call, and motivational telephone call). Cost accounting for each strategy followed by cost-effectiveness analysis. DATA SOURCE FOR EFFECTIVENESS: Randomized trial of three strategies conducted at Group Health Cooperative of Puget Sound (GHC). Women 50 to 79 years of age who were enrolled in GHC's breast cancer screening program who did not schedule screening mammography within 2 months after it was recommended by letter. Health plan. Marginal cost-effectiveness of each additional woman screened. Because of its high cost (about $26 per call) and intermediate effectiveness, the motivational call was the least cost-effective strategy. If it was assumed that 50% of the women who scheduled mammography after receiving the reminder postcard would have scheduled mammography within 10 months even without it, marginal cost-effectiveness for the postcard among all women was $22 per woman screened versus $92 for the reminder call. Among women with no previous mammography, the marginal cost-effectiveness for the postcard was $70 versus $100 for the reminder call. Among women with no previous mammography, the choice between the reminder postcard and the reminder call was sensitive to assumptions about the percentage of women expected to receive mammography in the absence of other promotional strategies. A simple reminder postcard is the most cost-effective way to increase mammography. Choices about how to promote mammography will ultimately depend on plan values and willingness to invest in promotional strategies that increase participation at higher unit costs.
Shillcutt, Samuel D; LeFevre, Amnesty E; Fischer-Walker, Christa L; Taneja, Sunita; Black, Robert E; Mazumder, Sarmila
2017-01-01
This study evaluates the cost-effectiveness of the DAZT program for scaling up treatment of acute child diarrhea in Gujarat India using a net-benefit regression framework. Costs were calculated from societal and caregivers' perspectives and effectiveness was assessed in terms of coverage of zinc and both zinc and Oral Rehydration Salt. Regression models were tested in simple linear regression, with a specified set of covariates, and with a specified set of covariates and interaction terms using linear regression with endogenous treatment effects was used as the reference case. The DAZT program was cost-effective with over 95% certainty above $5.50 and $7.50 per appropriately treated child in the unadjusted and adjusted models respectively, with specifications including interaction terms being cost-effective with 85-97% certainty. Findings from this study should be combined with other evidence when considering decisions to scale up programs such as the DAZT program to promote the use of ORS and zinc to treat child diarrhea.
Simple and efficient L-band erbium-doped fiber amplifiers for WDM networks
NASA Astrophysics Data System (ADS)
Choi, H. B.; Oh, J. M.; Lee, D.; Ahn, S. J.; Park, B. S.; Lee, S. B.
2002-11-01
The performance of L-band erbium-doped fiber amplifier (EDFA) of a simple structure with a fiber Bragg grating (FBG) was investigated. The injected C-band ASE by the FBG offers low-cost amplification and greatly improves the efficiency of the EDFA. There are 9 and 4 dB improvements with the FBG at 1587 nm, at low and high input, respectively. The flat gain of 18 dB, up to a total input of -5 dBm at 150 mW of 980 nm pump, is obtained over 30 nm with less than ±0.5 dB gain variations without any gain equalizer. The proposed EDFA provides a cost-effective solution for wavelength division multiplexing systems.
Diazo processing of LANDSAT imagery: A low-cost instructional technique
NASA Technical Reports Server (NTRS)
Lusch, D. P.
1981-01-01
Diazo processing of LANDSAT imagery is a relatively simple and cost effective method of producing enhanced renditions of the visual LANDSAT products. This technique is capable of producing a variety of image enhancements which have value in a teaching laboratory environment. Additionally, with the appropriate equipment, applications research which relys on accurate and repeatable results is possible. Exposure and development equipment options, diazo materials, and enhancement routines are discussed.
Passive solar design strategies: Remodeling guidelines for conserving energy at home
NASA Astrophysics Data System (ADS)
The idea of passive solar is simple, but applying it effectively does require information and attention to the details of design and construction. Some passive solar techniques are modest and low-cost, and require only small changes in remodeler's typical practice. At the other end of the spectrum, some passive solar systems can almost eliminate a house's need for purchased heating (and in some cases, cooling) energy - but probably at a relatively high first cost. In between are a broad range of energy-conserving passive solar techniques. Whether or not they are cost-effective, practical, and attractive enough to offer a market advantage to any individual remodeler depends on very specific factors such as local costs, climate, and market characteristics. Passive Solar Design Strategies: Remodeling Guidelines For Conserving Energy At Home is written to help give remodelers the information they need to make these decisions. Passive Solar Design Strategies is a package in three basic parts: the guidelines contain information about passive solar techniques and how they work, and provides specific examples of systems which will save various percentages of energy; the worksheets offer a simple, fill-in-the-blank method to pre-evaluate the performance of a specific design; and the worked example demonstrates how to complete the worksheets for a typical residence.
Psota, Marek; Psenkova, Maria Bucek; Racekova, Natalia; Ramirez de Arellano, Antonio; Vandebrouck, Tom; Hunt, Barnaby
2017-01-01
Aims To investigate the cost-effectiveness of once-daily insulin degludec/liraglutide (IDegLira) versus basal-bolus therapy in patients with type 2 diabetes not meeting glycemic targets on basal insulin from a healthcare payer perspective in Slovakia. Methods Long-term clinical and economic outcomes for patients receiving IDegLira and basal-bolus therapy were estimated using the IMS CORE Diabetes Model based on a published pooled analysis of patient-level data. Results IDegLira was associated with an improvement in quality-adjusted life expectancy of 0.29 quality-adjusted life years (QALYs) compared with basal-bolus therapy. The average lifetime cost per patient in the IDegLira arm was EUR 2,449 higher than in the basal-bolus therapy arm. Increased treatment costs with IDegLira were partially offset by cost savings from avoided diabetes-related complications. IDegLira was highly cost-effective versus basal-bolus therapy with an incremental cost-effectiveness ratio of EUR 8,590 per QALY gained, which is well below the cost-effectiveness threshold set by the law in Slovakia. Conclusion IDegLira is cost-effective in Slovakia, providing a simple option for intensification of basal insulin therapy without increasing the risk of hypoglycemia or weight gain and with fewer daily injections than a basal-bolus regimen. PMID:29276398
Proprietary hospitals in cost containment.
Jones, D A
1985-08-23
Any effort to control the rise in health care costs must start with analyzing the causes, which are really quite simple. Most cost control efforts fail because they do not address the causes. The causes are large subsidies in several forms that send a false message that health care is free and should be used abundantly, and expansive reimbursement programs that reward inefficient providers with higher payments. This combination of demand stimulation and cost-plus reimbursement produced the world's most expensive health care delivery system and strident calls for reform. A long overdue change in public policy took effect October 1, 1983, when Medicare payments moved from cost-plus reimbursement to fixed, prospectively determined prices. Because it addressed one of the causes of medical inflation, this change has been effective in slowing the rise in Medicare expenditures. Sponsorship of a hospital is not a determinant of its cost-effectiveness. There are examples of efficient and inefficient hospitals in both the voluntary and the investor-owned or taxpaying hospitals. The determining factor is the will of management to keep costs under control.
Evaluating the cost effectiveness of environmental projects: Case studies in aerospace and defense
NASA Technical Reports Server (NTRS)
Shunk, James F.
1995-01-01
Using the replacement technology of high pressure waterjet decoating systems as an example, a simple methodology is presented for developing a cost effectiveness model. The model uses a four-step process to formulate an economic justification designed for presentation to decision makers as an assessment of the value of the replacement technology over conventional methods. Three case studies from major U.S. and international airlines are used to illustrate the methodology and resulting model. Tax and depreciation impacts are also presented as potential additions to the model.
Evolutionary space platform concept study. Volume 2, part A: SASP special emphasis trade studies
NASA Technical Reports Server (NTRS)
1982-01-01
Efforts are in progress to define an approach to provide a simple and cost effective solution to the problem of long duration space flight. This approach involves a Space Platform in low Earth orbit, which can be tended by the Space Shuttle and which will provide, for extended periods of time, stability, utilities and access for a variety of replaceable payloads. The feasibility of an evolutionary space system which would cost effectively support unmanned payloads in groups, using a Space Platform which provides centralized basic subsystems is addressed.
Design and Field Test of a WSN Platform Prototype for Long-Term Environmental Monitoring
Lazarescu, Mihai T.
2015-01-01
Long-term wildfire monitoring using distributed in situ temperature sensors is an accurate, yet demanding environmental monitoring application, which requires long-life, low-maintenance, low-cost sensors and a simple, fast, error-proof deployment procedure. We present in this paper the most important design considerations and optimizations of all elements of a low-cost WSN platform prototype for long-term, low-maintenance pervasive wildfire monitoring, its preparation for a nearly three-month field test, the analysis of the causes of failure during the test and the lessons learned for platform improvement. The main components of the total cost of the platform (nodes, deployment and maintenance) are carefully analyzed and optimized for this application. The gateways are designed to operate with resources that are generally used for sensor nodes, while the requirements and cost of the sensor nodes are significantly lower. We define and test in simulation and in the field experiment a simple, but effective communication protocol for this application. It helps to lower the cost of the nodes and field deployment procedure, while extending the theoretical lifetime of the sensor nodes to over 16 years on a single 1 Ah lithium battery. PMID:25912349
Hoque, Sheikh Ariful; Hoshino, Hiroo; Anwar, Kazi Selim; Tanaka, Atsushi; Shinagawa, Masahiko; Hayakawa, Yuko; Okitsu, Shoko; Wada, Yuichi; Ushijima, Hiroshi
2013-02-01
The postnatal transmission of human immunodeficiency virus (HIV) from mothers to children occurs through breastfeeding. Although heat treatment of expressed breast milk is a promising approach to make breastfeeding safer, it is still not popular, mainly because the recommended procedures are difficult to follow, or time-consuming, or because mothers do not know which temperature is sufficient to inactivate HIV without destroying the nutritional elements of milk. To overcome these drawbacks, a simple and rapid method of heat treatment that a mother could perform with regular household materials applying her day-to-day art of cooking was examined. This structured experiment has demonstrated that both cell-free and cell-associated HIV type 1 (HIV-1) in expressed breast milk could be inactivated once the temperature of milk reached 65°C. Furthermore, a heating method as simple as heating the milk in a pan over a stove to 65°C inhibited HIV-1 transmission retaining milk's nutritional key elements, for example, total protein, IgG, IgA, and vitamin B(12) . This study has highlighted a simple, handy, and cost-effective method of heat treatment of expressed breast milk that mothers infected with HIV could apply easily and with more confidence. Copyright © 2012 Wiley Periodicals, Inc.
In Vivo Effects of Barbituates on Seed Germination and Seedling Growth.
ERIC Educational Resources Information Center
Kordan, H. A.
1984-01-01
A simple, low-cost experimental system can be used to demonstrate the "in vivo" effects of barbituates on seed germination and seedling growth behavior in different plant species. Lipid solubility and concentration of individual barbituates both affect the response. List of materials needed, procedures used, and typical results obtained are…
Essays on Experimental Economics and Education
ERIC Educational Resources Information Center
Ogawa, Scott Richard
2013-01-01
In Chapter 1 I consider three separate explanations for how price affects the usage rate of a purchased product: Screening, signaling, and sunk-cost bias. I propose an experimental design that disentangles the three effects. Furthermore, in order to quantify and compare these effects I introduce a simple structural model and show that the…
Cost-effectiveness on a local level: whether and when to adopt a new technology.
Woertman, Willem H; Van De Wetering, Gijs; Adang, Eddy M M
2014-04-01
Cost-effectiveness analysis has become a widely accepted tool for decision making in health care. The standard textbook cost-effectiveness analysis focuses on whether to make the switch from an old or common practice technology to an innovative technology, and in doing so, it takes a global perspective. In this article, we are interested in a local perspective, and we look at the questions of whether and when the switch from old to new should be made. A new approach to cost-effectiveness from a local (e.g., a hospital) perspective, by means of a mathematical model for cost-effectiveness that explicitly incorporates time, is proposed. A decision rule is derived for establishing whether a new technology should be adopted, as well as a general rule for establishing when it pays to postpone adoption by 1 more period, and a set of decision rules that can be used to determine the optimal timing of adoption. Finally, a simple example is presented to illustrate our model and how it leads to optimal decision making in a number of cases.
QR Codes: Outlook for Food Science and Nutrition.
Sanz-Valero, Javier; Álvarez Sabucedo, Luis M; Wanden-Berghe, Carmina; Santos Gago, Juan M
2016-01-01
QR codes opens up the possibility to develop simple-to-use, cost-effective-cost, and functional systems based on the optical recognition of inexpensive tags attached to physical objects. These systems, combined with Web platforms, can provide us with advanced services that are already currently broadly used on many contexts of the common life. Due to its philosophy, based on the automatic recognition of messages embedded on simple graphics by means of common devices such as mobile phones, QR codes are very convenient for the average user. Regretfully, its potential has not yet been fully exploited in the domains of food science and nutrition. This paper points out some applications to make the most of this technology for these domains in a straightforward manner. For its characteristics, we are addressing systems with low barriers to entry and high scalability for its deployment. Therefore, its launching among professional and final users is quite simple. The paper also provides high-level indications for the evaluation of the technological frame required to implement the identified possibilities of use.
Oda, Hitomi; Miyauchi, Akira; Ito, Yasuhiro; Sasai, Hisanori; Masuoka, Hiroo; Yabuta, Tomonori; Fukushima, Mitsuhiro; Higashiyama, Takuya; Kihara, Minoru; Kobayashi, Kaoru; Miya, Akihiro
2017-01-30
The incidence of thyroid cancer is increasing rapidly in many countries, resulting in rising societal costs of the care of thyroid cancer. We reported that the active surveillance of low-risk papillary microcarcinoma had less unfavorable events than immediate surgery, while the oncological outcomes of these managements were similarly excellent. Here we calculated the medical costs of these two managements. We created a model of the flow of these managements, based on our previous study. The flow and costs include the step of diagnosis, surgery, prescription of medicine, recurrence, salvage surgery for recurrence, and care for 10 years after the diagnosis. The costs were calculated according to the typical clinical practices at Kuma Hospital performed under the Japanese Health Care Insurance System. If conversion surgeries were not considered, the 'simple cost' of active surveillance for 10 years was 167,780 yen/patient. If there were no recurrences, the 'simple cost' of immediate surgery was calculated as 794,770 yen/patient to 1,086,070 yen/patient, depending on the type of surgery and postoperative medication. The 'simple cost' of surgery was 4.7 to 6.5 times the 'simple cost' of surveillance. When conversion surgeries and recurrence were considered, the 'total cost' of active surveillance for 10 years became 225,695 yen/patient. When recurrence were considered, the 'total cost' of immediate surgery was 928,094 yen/patient, which was 4.1 times the 'total cost' of the active surveillance. At Kuma Hospital in Japan, the 10-year total cost of immediate surgery was 4.1 times expensive than active surveillance.
A case report on the remodelling technique for the earlobe using a soft splint.
Vaiude, Partha N; Anthony, Edwin T; Syed, Mobin; Ilyas, Syed
2008-01-01
Correcting earlobe deformities often presents an aesthetic challenge to the surgeon. The described technique presents a simple, accurate and cost effective method of remodelling soft tissue defects of the earlobe using a soft splint.
Essays on wholesale auctions in deregulated electricity markets
NASA Astrophysics Data System (ADS)
Baltaduonis, Rimvydas
2007-12-01
The early experience in the restructured electric power markets raised several issues, including price spikes, inefficiency, security, and the overall relationship of market clearing prices to generation costs. Unsatisfactory outcomes in these markets are thought to have resulted in part from strategic generator behaviors encouraged by inappropriate market design features. In this dissertation, I examine the performance of three auction mechanisms for wholesale power markets - Offer Cost Minimization auction, Payment Cost Minimization auction and Simple-Offer auction - when electricity suppliers act strategically. A Payment Cost Minimization auction has been proposed as an alternative to the traditional Offer Cost Minimization auction with the intention to solve the problem of inflated wholesale electricity prices. Efficiency concerns for this proposal were voiced due to insights predicated on the assumption of true production cost revelation. Using a game theoretic approach and an experimental method, I compare the two auctions, strictly controlling for the level of unilateral market power. A specific feature of these complex-offer auctions is that the sellers submit not only the quantities and the minimum prices that they are willing to sell at, but also the start-up fees, which are designed to reimburse the fixed start-up costs of the generation plants. I find that the complex structure of the offers leaves considerable room for strategic behavior, which consequently leads to anti-competitive and inefficient market outcomes. In the last chapter of my dissertation, I use laboratory experiments to contrast the performance of two complex-offer auctions against the performance of a simple-offer auction, in which the sellers have to recover all their generation costs - fixed and variable - through a uniform market-clearing price. I find that a simple-offer auction significantly reduces consumer prices and lowers price volatility. It mitigates anti-competitive effects that are present in the complex-offer auctions and achieves allocative efficiency more quickly.
ERIC Educational Resources Information Center
Pe´rez, Eduardo
2015-01-01
The procedure of a physical chemistry experiment for university students must be designed in a way that the accuracy and precision of the measurements is properly maintained. However, in many cases, that requires costly and sophisticated equipment not readily available in developing countries. A simple, low-cost experiment to determine isobaric…
Korber, Katharina; Wolfenstetter, Silke Britta
2017-03-08
It is a desirable medical as well as health economic objective to achieve the best possible health effects with given financial resources. Estimating the costs of intervention programs is complex and not always possible in advance. One possibility to obtain information on costs or cost effectiveness of certain interventions is to assess programs already in existence. The aim of this article was to develop a simple, easy to understand and practical possibility of documenting costs of prevention and health promotion programs. Based on the fundamentals necessary for cost assessment, a questionnaire and a module to document the consumed resources and the resultant costs were developed. These were applied and improved within a pre-test. The developed cost module is as follows: In the left column, 5 key cost categories are listed: personnel, rooms, equipment and process, management, other costs. The cost module is a compromise between different objectives that are difficult to reconcile. On the one hand, the costs should be documented as detailed as possible and on the other, the module must be very simple to implement, as otherwise it will not be used in practice. For this purpose, it might also be useful to develop a module for each stakeholder that is aligned as closely as possible to his or her special activities. All feedback and suggestions from the pre-test were incorporated. However, some of the feedback points were project specific. Here an attempt was made to find a compromise between detail and practicality. This was done by implementing more detailed descriptions and examples in the manual. The presented module is very general. This also is a great advantage because it can be used to document the costs of completely different stakeholders. Thus, the concept presented here for cost assessment provides a first and essential component for a detailed documentation of program costs and provides the potential to check comparability and transferability of those prevention programs. © Georg Thieme Verlag KG Stuttgart · New York.
Lamberts, Mark P; Özdemir, Cihan; Drenth, Joost P H; van Laarhoven, Cornelis J H M; Westert, Gert P; Kievit, Wietske
2017-06-01
The aim of this study was to determine the cost-effectiveness of a new strategy for the preoperative detection of patients that will likely benefit from a cholecystectomy, using simple criteria that can be applied by surgeons. Criteria for a cholecystectomy indication are: (1) having episodic pain; (2) onset of pain 1 year or less before the outpatient clinic visit. The cost-effectiveness of the new strategy was evaluated against current practice using a decision analytic model. The incremental cost-effectiveness of applying criteria for a cholecystectomy for a patient with abdominal pain and gallstones was compared to applying no criteria. The incremental cost-effectiveness ratio (ICER) was expressed as extra costs to be invested to gain one more patient with absence of pain. Scenarios were analyzed to assess the influence of applying different criteria. The new strategy of applying one out of two criteria resulted in a 4 % higher mean proportion of patients with absence of pain compared to current practice with similar costs. The 95 % upper limit of the ICER was €4114 ($4633) per extra patient with relief of upper abdominal pain. Application of two out of two criteria resulted in a 3 % lower mean proportion of patients with absence of pain with lower costs. The new strategy of using one out of two strict selection criteria may be an effective but also a cost-effective method to reduce the proportion of patients with pain after cholecystectomy.
Gutmann, Torsten; Ratajczyk, Tomasz; Dillenberger, Sonja; Xu, Yeping; Grünberg, Anna; Breitzke, Hergen; Bommerich, Ute; Trantzschel, Thomas; Bernarding, Johannes; Buntkowsky, Gerd
2011-09-01
It is shown that the para-hydrogen induced polarization (PHIP) phenomenon in homogenous solution containing the substrate styrene is also observable employing simple inorganic systems of the form MCl(3)·xH(2)O (M=Rh, Ir) as catalyst. Such observation confirms that already very simple metal complexes enable the creation of PHIP signal enhancement in solution. This opens up new pathways to increase the sensitivity of NMR and MRT by PHIP enhancement using cost-effective catalysts and will be essential for further mechanistic studies of simple transition metal systems. Copyright © 2011 Elsevier Inc. All rights reserved.
Variability in Costs across Hospital Wards. A Study of Chinese Hospitals
Adam, Taghreed; Evans, David B.; Ying, Bian; Murray, Christopher J. L.
2014-01-01
Introduction Analysts estimating the costs or cost-effectiveness of health interventions requiring hospitalization often cut corners because they lack data and the costs of undertaking full step-down costing studies are high. They sometimes use the costs taken from a single hospital, sometimes use simple rules of thumb for allocating total hospital costs between general inpatient care and the outpatient department, and sometimes use the average cost of an inpatient bed-day instead of a ward-specific cost. Purpose In this paper we explore for the first time the extent and the causes of variation in ward-specific costs across hospitals, using data from China. We then use the resulting model to show how ward-specific costs for hospitals outside the data set could be estimated using information on the determinants identified in the paper. Methodology Ward-specific costs estimated using step-down costing methods from 41 hospitals in 12 provinces of China were used. We used seemingly unrelated regressions to identify the determinants of variability in the ratio of the costs of specific wards to that of the outpatient department, and explain how this can be used to generate ward-specific unit costs. Findings Ward-specific unit costs varied considerably across hospitals, ranging from 1 to 24 times the unit cost in the outpatient department — average unit costs are not a good proxy for costs at specialty wards in general. The most important sources of variability were the number of staff and the level of capacity utilization. Practice Implications More careful hospital costing studies are clearly needed. In the meantime, we have shown that in China it is possible to estimate ward-specific unit costs taking into account key determinants of variability in costs across wards. This might well be a better alternative than using simple rules of thumb or using estimates from a single study. PMID:24874566
Using a crowdsourced approach for monitoring water level in a remote Kenyan catchment
NASA Astrophysics Data System (ADS)
Weeser, Björn; Jacobs, Suzanne; Rufino, Mariana; Breuer, Lutz
2017-04-01
Hydrological models or effective water management strategies only succeed if they are based on reliable data. Decreasing costs of technical equipment lower the barrier to create comprehensive monitoring networks and allow both spatial and temporal high-resolution measurements. However, these networks depend on specialised equipment, supervision, and maintenance producing high running expenses. This becomes particularly challenging for remote areas. Low income countries often do not have the capacity to run such networks. Delegating simple measurements to citizens living close to relevant monitoring points may reduce costs and increase the public awareness. Here we present our experiences of using a crowdsourced approach for monitoring water levels in remote catchments in Kenya. We established a low-cost system consisting of thirteen simple water level gauges and a Raspberry Pi based SMS-Server for data handling. Volunteers determine the water level and transmit their records using a simple text message. These messages are automatically processed and real-time feedback on the data quality is given. During the first year, more than 1200 valid records with high quality have been collected. In summary, the simple techniques for data collecting, transmitting and processing created an open platform that has the potential for reaching volunteers without the need for special equipment. Even though the temporal resolution of measurements cannot be controlled and peak flows might be missed, this data can still be considered as a valuable enhancement for developing management strategies or for hydrological modelling.
NASA Astrophysics Data System (ADS)
Ye, Xiaosheng; Shi, Hui; He, Xiaoxiao; Yu, Yanru; He, Dinggeng; Tang, Jinlu; Lei, Yanli; Wang, Kemin
2016-01-01
As a star material in cancer theranostics, photoresponsive gold (Au) nanostructures may still have drawbacks, such as low thermal conductivity, irradiation-induced melting effect and high cost. To solve the problem, copper (Cu) with a much higher thermal conductivity and lower cost was introduced to generate a novel Cu-Au alloy nanostructure produced by a simple, gentle and one-pot synthetic method. Having the good qualities of both Cu and Au, the irregularly-shaped Cu-Au alloy nanostructures showed several advantages over traditional Au nanorods, including a broad and intense near-infrared (NIR) absorption band from 400 to 1100 nm, an excellent heating performance under laser irradiation at different wavelengths and even a notable photostability against melting. Then, via a simple conjugation of fluorophore-labeled aptamers on the Cu-Au alloy nanostructures, active targeting and signal output were simultaneously introduced, thus constructing a theranostic platform based on fluorophore-labeled, aptamer-coated Cu-Au alloy nanostructures. By using human leukemia CCRF-CEM cancer and Cy5-labeled aptamer Sgc8c (Cy5-Sgc8c) as the model, a selective fluorescence imaging and NIR photothermal therapy was successfully realized for both in vitro cancer cells and in vivo tumor tissues. It was revealed that Cy5-Sgc8c-coated Cu-Au alloy nanostructures were not only capable of robust target recognition and stable signal output for molecular imaging in complex biological systems, but also killed target cancer cells in mice with only five minutes of 980 nm irradiation. The platform was found to be simple, stable, biocompatible and highly effective, and shows great potential as a versatile tool for cancer theranostics.As a star material in cancer theranostics, photoresponsive gold (Au) nanostructures may still have drawbacks, such as low thermal conductivity, irradiation-induced melting effect and high cost. To solve the problem, copper (Cu) with a much higher thermal conductivity and lower cost was introduced to generate a novel Cu-Au alloy nanostructure produced by a simple, gentle and one-pot synthetic method. Having the good qualities of both Cu and Au, the irregularly-shaped Cu-Au alloy nanostructures showed several advantages over traditional Au nanorods, including a broad and intense near-infrared (NIR) absorption band from 400 to 1100 nm, an excellent heating performance under laser irradiation at different wavelengths and even a notable photostability against melting. Then, via a simple conjugation of fluorophore-labeled aptamers on the Cu-Au alloy nanostructures, active targeting and signal output were simultaneously introduced, thus constructing a theranostic platform based on fluorophore-labeled, aptamer-coated Cu-Au alloy nanostructures. By using human leukemia CCRF-CEM cancer and Cy5-labeled aptamer Sgc8c (Cy5-Sgc8c) as the model, a selective fluorescence imaging and NIR photothermal therapy was successfully realized for both in vitro cancer cells and in vivo tumor tissues. It was revealed that Cy5-Sgc8c-coated Cu-Au alloy nanostructures were not only capable of robust target recognition and stable signal output for molecular imaging in complex biological systems, but also killed target cancer cells in mice with only five minutes of 980 nm irradiation. The platform was found to be simple, stable, biocompatible and highly effective, and shows great potential as a versatile tool for cancer theranostics. Electronic supplementary information (ESI) available: Fig. S1, S2 and Table S1. See DOI: 10.1039/c5nr07017a
Steininger, M S; Hulcr, J; Šigut, M; Lucky, A
2015-06-01
Bark and ambrosia beetles (Coleoptera: Curculionidae: Scolytinae & Platypodinae) are among the most damaging forest pests worldwide, and monitoring is essential to damage prevention. Unfortunately, traps and attractants that are currently used are costly, and agencies rely on limited field personnel for deployment. The situation can be greatly aided by 1) the development of cost-effective trapping techniques, and 2) distribution of the effort through the Citizen Science approach. The goal of this study was to test a simple, effective trap that can be made and deployed by anyone interested in collecting bark and ambrosia beetles. Three trap types made from 2-liter soda bottles and, separately, four attractants were compared. Simple, one-window traps performed comparably at capturing species in traps painted or with multiple windows. A comparison of attractants in two-window traps found that 95% ethanol attracted the highest number of species but that Purell hand sanitizer (70% ethanol) and then Germ-X hand sanitizer (63% ethanol) were also effective. A perforated zip-top plastic bag containing Purell hanging over a trap filled with automobile antifreeze attracted the fewest species and individual specimens. Overall, >4,500 bark and ambrosia beetles, including 30 species were captured, representing a third of the regional species diversity. More than three quarters of the specimens were nonnative, representing nearly half of the known regional exotic species. These results suggest that simple one-window soda bottle traps baited with ethanol-based hand sanitizer will be effective and inexpensive tools for large-scale monitoring of bark and ambrosia beetles. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
A simple method to locate changes in vegetation cover, which can be used to identify areas under stress. The method only requires inexpensive NDVI data. The use of remotely sensed data is far more cost-effective than field studies and can be performed more quickly. Local knowledg...
ERIC Educational Resources Information Center
Goldcamp, Michael J.; Underwood, Melinda N.; Cloud, Joshua L.; Harshman, Sean
2008-01-01
Contamination of the environment with heavy metals such as lead presents many health risks. Simple, effective, and field-portable methods for the measurement of toxic metals in environmental samples are vital tools for evaluating the risks that these contaminants pose. This article describes the use of new developments in anodic stripping…
Dobhal, S; Zhang, G; Rohla, C; Smith, M W; Ma, L M
2014-10-01
PCR is widely used in the routine detection of foodborne human pathogens; however, challenges remain in overcoming PCR inhibitors present in some sample matrices. The objective of this study was to develop a simple, sensitive, cost-effective and rapid method for processing large numbers of environmental and pecan samples for Salmonella detection. This study was also aimed at validation of a new protocol for the detection of Salmonella from in-shell pecans. Different DNA template preparation methods, including direct boiling, prespin, multiple washing and commercial DNA extraction kits, were evaluated with pure cultures of Salmonella Typhimurium and with enriched soil, cattle feces and in-shell pecan each spiked individually with Salmonella Typhimurium. PCR detection of Salmonella was conducted using invA and 16S rRNA gene (internal amplification control) specific primers. The effect of amplification facilitators, including bovine serum albumin (BSA), polyvinylpyrrolidone (PVP), polyethylene glycol (PEG) and gelatin on PCR sensitivity, was also evaluated. Conducting a prespin of sample matrices in combination with the addition of 0·4% (w/v) BSA and 1% (w/v) PVP in PCR mix was the simplest, most rapid, cost-effective and sensitive method for PCR detection of Salmonella, with up to 40 CFU Salmonella per reaction detectable in the presence of over 10(9 ) CFU ml(-1) of background micro-organisms from enriched feces soil or pecan samples. The developed method is rapid, cost-effective and sensitive for detection of Salmonella from different matrices. This study provides a method with broad applicability for PCR detection of Salmonella in complex sample matrices. This method has a potential for its application in different research arenas and diagnostic laboratories. © 2014 The Society for Applied Microbiology.
Zarei, Omid; Dastmalchi, Siavoush; Hamzeh-Mivehroud, Maryam
2016-01-01
Yeasts, especially Saccharomyces cerevisiae, are one of the oldest organisms with broad spectrum of applications, owing to their unique genetics and physiology. Yeast extract, i.e. the product of yeast cells, is extensively used as nutritional resource in bacterial culture media. The aim of this study was to develop a simple, rapid and cost benefit process to produce the yeast extract. In this procedure mechanical methods such as high temperature and pressure were utilized to produce the yeast extract. The growth of the bacteria feed with the produced yeast extract was monitored in order to assess the quality of the product. The results showed that the quality of the produced yeast extract was very promising concluded from the growth pattern of bacterial cells in media prepared from this product and was comparable with that of the three commercial yeast extracts in terms of bacterial growth properties. One of the main advantages of the current method was that no chemicals and enzymes were used, leading to the reduced production cost. The method is very simple and cost effective, and can be performed in a reasonable time making it suitable for being adopted by research laboratories. Furthermore, it can be scaled up to produce large quantities for industrial applications. PMID:28243289
A Marxian interpretation of the growth and development of coronary care technology.
Waitzkin, H
1979-01-01
Cost containment efforts will fail if they continue to ignore the structural relationships between health care costs and private profit in capitalist society. The recent history of coronary care shows that apparent irrationalities of health policy make sense from the standpoint of capitalist profit structure. Coronary care units (CCUs) gained wide acceptance, despite high costs. Studies of CCU effectiveness, using random controlled trials and epidemiologic techniques, do not show a consistent advantage of CCUs over non-intensive ward care or simple rest at home. From a Marxian perspective, the proliferation of CCUs and similar innovations is a complex historical process that includes initiatives by industrial corporations, cooperation by clinical investigators at academic medical centers, support by private philanthropies linked to corporate interests, intervention by state agencies, and changes in the health care labor force. Cost-effective methodology obscures the profit motive as a basic source of high costs and ineffective practices. Health-policy alternatives curtailing corporate involvement in medicine would reduce costs by restricting profit. PMID:116553
Development and Validation of the Texas Best Management Practice Evaluation Tool (TBET)
USDA-ARS?s Scientific Manuscript database
Conservation planners need simple yet accurate tools to predict sediment and nutrient losses from agricultural fields to guide conservation practice implementation and increase cost-effectiveness. The Texas Best management practice Evaluation Tool (TBET), which serves as an input/output interpreter...
Plastic carrier polishing chamber reduces pollution swapping from denitrifying woodchip bioreactors
USDA-ARS?s Scientific Manuscript database
Denitrifying bioreactors with solid organic carbon sources (i.e., “woodchip bioreactors”) have proven to be relatively simple and cost effective treatment systems for nitrate-laden agricultural and aquacultural waters and wastewaters. However, because this technology is still relatively new, design ...
Inexpensive and fast pathogenic bacteria screening using field-effect transistors.
Formisano, Nello; Bhalla, Nikhil; Heeran, Mel; Reyes Martinez, Juana; Sarkar, Amrita; Laabei, Maisem; Jolly, Pawan; Bowen, Chris R; Taylor, John T; Flitsch, Sabine; Estrela, Pedro
2016-11-15
While pathogenic bacteria contribute to a large number of globally important diseases and infections, current clinical diagnosis is based on processes that often involve culturing which can be time-consuming. Therefore, innovative, simple, rapid and low-cost solutions to effectively reduce the burden of bacterial infections are urgently needed. Here we demonstrate a label-free sensor for fast bacterial detection based on metal-oxide-semiconductor field-effect transistors (MOSFETs). The electric charge of bacteria binding to the glycosylated gates of a MOSFET enables quantification in a straightforward manner. We show that the limit of quantitation is 1.9×10(5) CFU/mL with this simple device, which is more than 10,000-times lower than is achieved with electrochemical impedance spectroscopy (EIS) and matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-ToF) on the same modified surfaces. Moreover, the measurements are extremely fast and the sensor can be mass produced at trivial cost as a tool for initial screening of pathogens. Copyright © 2016 Elsevier B.V. All rights reserved.
Hi-Plex for Simple, Accurate, and Cost-Effective Amplicon-based Targeted DNA Sequencing.
Pope, Bernard J; Hammet, Fleur; Nguyen-Dumont, Tu; Park, Daniel J
2018-01-01
Hi-Plex is a suite of methods to enable simple, accurate, and cost-effective highly multiplex PCR-based targeted sequencing (Nguyen-Dumont et al., Biotechniques 58:33-36, 2015). At its core is the principle of using gene-specific primers (GSPs) to "seed" (or target) the reaction and universal primers to "drive" the majority of the reaction. In this manner, effects on amplification efficiencies across the target amplicons can, to a large extent, be restricted to early seeding cycles. Product sizes are defined within a relatively narrow range to enable high-specificity size selection, replication uniformity across target sites (including in the context of fragmented input DNA such as that derived from fixed tumor specimens (Nguyen-Dumont et al., Biotechniques 55:69-74, 2013; Nguyen-Dumont et al., Anal Biochem 470:48-51, 2015), and application of high-specificity genetic variant calling algorithms (Pope et al., Source Code Biol Med 9:3, 2014; Park et al., BMC Bioinformatics 17:165, 2016). Hi-Plex offers a streamlined workflow that is suitable for testing large numbers of specimens without the need for automation.
Route to one-step microstructure mold fabrication for PDMS microfluidic chip
NASA Astrophysics Data System (ADS)
Lv, Xiaoqing; Geng, Zhaoxin; Fan, Zhiyuan; Wang, Shicai; Su, Yue; Fang, Weihao; Pei, Weihua; Chen, Hongda
2018-04-01
The microstructure mold fabrication for PDMS microfluidic chip remains complex and time-consuming process requiring special equipment and protocols: photolithography and etching. Thus, a rapid and cost-effective method is highly needed. Comparing with the traditional microfluidic chip fabricating process based on the micro-electromechanical system (MEMS), this method is simple and easy to implement, and the whole fabrication process only requires 1-2 h. Different size of microstructure from 100 to 1000 μm was fabricated, and used to culture four kinds of breast cancer cell lines. Cell viability and morphology was assessed when they were cultured in the micro straight channels, micro square holes and the bonding PDMS-glass microfluidic chip. The experimental results indicate that the microfluidic chip is good and meet the experimental requirements. This method can greatly reduce the process time and cost of the microfluidic chip, and provide a simple and effective way for the structure design and in the field of biological microfabrications and microfluidic chips.
Gopal, Venu; Ganesh, Praveen; Nagarjuna, Muralidhara; Kumar, Kiran; Shetty, Samarth; Salins, Paul C.
2015-01-01
Aim To fabricate a cost effective, indigenous and simple orthotics helmet for post-operative cranial molding in patients with craniosynostosis surgery. Methods We present a case of 15 month old infant with secondary cranial vault deformity. Cranial vault remodeling surgery involving the posterior skull was planned and executed to increase the posterior gap, so that brain growth would be facilitated towards this empty space. Materials such as thermoplastic sponge, thermoplastic ionomer resin sheet, soft sponge and Velcro straps are used to fabricate a cranial orthotics helmet. Results We have successfully used the above materials to fabricate the orthotics helmet for post-operative cranial molding. Conclusion The technique described in this article is simple and cost effective. It can be custom made according to the demands of the surgical technique and the type of synostosis. It favors an individualistic prognosis, and proves worthwhile as every synostosis requires a unique treatment plan. It is an excellent adjuvant to craniosynostosis remodeling surgery. PMID:26258018
NASA Astrophysics Data System (ADS)
So, Hongyun; Senesky, Debbie G.
2016-11-01
Rapid, cost-effective, and simple fabrication/packaging of microscale gallium nitride (GaN) ultraviolet (UV) sensors are demonstrated using zinc oxide nanorod arrays (ZnO NRAs) as an antireflective layer and direct bonding of aluminum wires to the GaN surface. The presence of the ZnO NRAs on the GaN surface significantly reduced the reflectance to less than 1% in the UV and 4% in the visible light region. As a result, the devices fabricated with ZnO NRAs and mechanically stable aluminum bonding wires (pull strength of 3-5 gf) showed higher sensitivity (136.3% at room temperature and 148.2% increase at 250 °C) when compared with devices with bare (uncoated) GaN surfaces. In addition, the devices demonstrated reliable operation at high temperatures up to 300 °C, supporting the feasibility of simple and cost-effective UV sensors operating with higher sensitivity in high-temperature conditions, such as in combustion, downhole, and space exploration applications.
Kuntalp, Mehmet; Akar, Orkun
2004-08-01
In many developing countries including Turkey, telemedicine systems are not in wide use due to the high cost and complexity of the required technology. Lack of these systems however has serious implications on patients who live in rural areas. The objective of this paper is to present a simple and economically affordable alternative to the current systems that would allow experts to easily access the medical data of their remote patients over the Internet. The system is developed in client-server architecture with a user-friendly graphical interface and various services are implemented as dynamic web pages based on PHP. The other key features of the system are its powerful security features and platform independency. An academic prototype is implemented and presented to the evaluation of a group of physicians. The results reveal that the system could find acceptance from the medical community and it could be an effective means of providing quality health care in developing countries.
Schechter, Clyde B; Basch, Charles E; Caban, Arlene; Walker, Elizabeth A
2008-01-01
In a clinical trial, we have previously shown that a telephone intervention can significantly increase participation in dilated fundus examination (DFE) screening among low-income adults with diabetes. Here the costs and cost-effectiveness ratio of this intervention are calculated. Intervention effectiveness was estimated as the difference in DFE utilization between the telephone intervention and print groups from the clinical trial multiplied by the size of the telephone intervention group. A micro-costing approach was used. Personnel time was aggregated from logs kept during the clinical trial of the intervention. Wage rates were taken from a commercial compensation database. Telephone charges were estimated based on prevailing fees. The cost-effectiveness ratio was calculated as the ratio of total costs of the intervention to the number of DFEs gained by the intervention. A sensitivity analysis estimated the cost-effectiveness of a more limited telephone intervention. A probabilistic sensitivity analysis using bootstrap samples from the clinical trial results quantified the uncertainties in resource utilization and intervention effectiveness. Net intervention costs were US$18,676.06, with an associated gain of 43.7 DFEs and 16.4 new diagnoses of diabetic retinopathy. The cost-effectiveness ratio is US$427.37 per DFE gained. A restricted intervention limiting the number of calls to 5, as opposed to 7, would achieve the same results, but would cost approximately 17% less. In the probabilistic sensitivity analysis, the 5th and 95th percentiles of the cost-effectiveness ratio were US$304.05 and US$692.52 per DFE gained, respectively. Our telephone intervention is more expensive than simple mail or telephone reminders used in other settings to promote preventive care; it is, however, also considerably more effective, and is effective in a low-income minority population at greater risk for diabetes complications. The costs are dominated by labor costs, and may be substantially defrayed, without loss of effectiveness, by restricting the number of telephone calls to 5 per patient. PMID:19668428
A Cost-Effective Energy-Recovering Sustain Driving Circuit for ac Plasma Display Panels
NASA Astrophysics Data System (ADS)
Lim, Jae Kwang; Tae, Heung-Sik; Choi, Byungcho; Kim, Seok Gi
A new sustain driving circuit, featuring an energy-recovering function with simple structure and minimal component count, is proposed as a cost-effective solution for driving plasma display panels during the sustaining period. Compared with existing solutions, the proposed circuit reduces the number of semiconductor switches and reactive circuit components without compromising the circuit performance and gas-discharging characteristics. In addition, the proposed circuit utilizes the harness wire as an inductive circuit component, thereby further simplifying the circuit structure. The performance of the proposed circuit is confirmed with a 42-inch plasma display panel.
Mori, Amani T; Ngalesoni, Frida; Norheim, Ole F; Robberstad, Bjarne
2014-09-15
Dihydroartemisinin-piperaquine (DhP) is highly recommended for the treatment of uncomplicated malaria. This study aims to compare the costs, health benefits and cost-effectiveness of DhP and artemether-lumefantrine (AL) alongside "do-nothing" as a baseline comparator in order to consider the appropriateness of DhP as a first-line anti-malarial drug for children in Tanzania. A cost-effectiveness analysis was performed using a Markov decision model, from a provider's perspective. The study used cost data from Tanzania and secondary effectiveness data from a review of articles from sub-Saharan Africa. Probabilistic sensitivity analysis was used to incorporate uncertainties in the model parameters. In addition, sensitivity analyses were used to test plausible variations of key parameters and the key assumptions were tested in scenario analyses. The model predicts that DhP is more cost-effective than AL, with an incremental cost-effectiveness ratio (ICER) of US$ 12.40 per DALY averted. This result relies on the assumption that compliance to treatment with DhP is higher than that with AL due to its relatively simple once-a-day dosage regimen. When compliance was assumed to be identical for the two drugs, AL was more cost-effective than DhP with an ICER of US$ 12.54 per DALY averted. DhP is, however, slightly more likely to be cost-effective compared to a willingness-to-pay threshold of US$ 150 per DALY averted. Dihydroartemisinin-piperaquine is a very cost-effective anti-malarial drug. The findings support its use as an alternative first-line drug for treatment of uncomplicated malaria in children in Tanzania and other sub-Saharan African countries with similar healthcare infrastructures and epidemiology of malaria.
A cost assessment of reliability requirements for shuttle-recoverable experiments
NASA Technical Reports Server (NTRS)
Campbell, J. W.
1975-01-01
The relaunching of unsuccessful experiments or satellites will become a real option with the advent of the space shuttle. An examination was made of the cost effectiveness of relaxing reliability requirements for experiment hardware by allowing more than one flight of an experiment in the event of its failure. Any desired overall reliability or probability of mission success can be acquired by launching an experiment with less reliability two or more times if necessary. Although this procedure leads to uncertainty in total cost projections, because the number of flights is not known in advance, a considerable cost reduction can sometimes be achieved. In cases where reflight costs are low relative to the experiment's cost, three flights with overall reliability 0.9 can be made for less than half the cost of one flight with a reliability of 0.9. An example typical of shuttle payload cost projections is cited where three low reliability flights would cost less than $50 million and a single high reliability flight would cost over $100 million. The ratio of reflight cost to experiment cost is varied and its effect on the range in total cost is observed. An optimum design reliability selection criterion to minimize expected cost is proposed, and a simple graphical method of determining this reliability is demonstrated.
Proton facility economics: the importance of "simple" treatments.
Johnstone, Peter A S; Kerstiens, John; Richard, Helsper
2012-08-01
Given the cost and debt incurred to build a modern proton facility, impetus exists to minimize treatment of patients with complex setups because of their slower throughput. The aim of this study was to determine how many "simple" cases are necessary given different patient loads simply to recoup construction costs and debt service, without beginning to cover salaries, utilities, beam costs, and so on. Simple cases are ones that can be performed quickly because of an easy setup for the patient or because the patient is to receive treatment to just one or two fields. A "standard" construction cost and debt for 1, 3, and 4 gantry facilities were calculated from public documents of facilities built in the United States, with 100% of the construction funded through standard 15-year financing at 5% interest. Clinical best case (that each room was completely scheduled with patients over a 14-hour workday) was assumed, and a statistical analysis was modeled with debt, case mix, and payer mix moving independently. Treatment times and reimbursement data from the investigators' facility for varying complexities of patients were extrapolated for varying numbers treated daily. Revenue assumptions of $X per treatment were assumed both for pediatric cases (a mix of Medicaid and private payer) and state Medicare simple case rates. Private payer reimbursement averages $1.75X per treatment. The number of simple patients required daily to cover construction and debt service costs was then derived. A single gantry treating only complex or pediatric patients would need to apply 85% of its treatment slots simply to service debt. However, that same room could cover its debt treating 4 hours of simple patients, thus opening more slots for complex and pediatric patients. A 3-gantry facility treating only complex and pediatric cases would not have enough treatment slots to recoup construction and debt service costs at all. For a 4-gantry center, focusing on complex and pediatric cases alone, there would not be enough treatment slots to cover even 60% of debt service. Personnel and recurring costs and profit further reduce the business case for performing more complex patients. Debt is not variable with capacity. Absent philanthropy, financing a modern proton center requires treating a case load emphasizing simple patients even before operating costs and any profit are achieved. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Borden, C. S.; Volkmer, K.; Cochrane, E. H.; Lawson, A. C.
1984-01-01
A simple methodology to estimate photovoltaic system size and life-cycle costs in stand-alone applications is presented. It is designed to assist engineers at Government agencies in determining the feasibility of using small stand-alone photovoltaic systems to supply ac or dc power to the load. Photovoltaic system design considerations are presented as well as the equations for sizing the flat-plate array and the battery storage to meet the required load. Cost effectiveness of a candidate photovoltaic system is based on comparison with the life-cycle cost of alternative systems. Examples of alternative systems addressed are batteries, diesel generators, the utility grid, and other renewable energy systems.
[Cost variation in care groups?
Mohnen, S M; Molema, C C M; Steenbeek, W; van den Berg, M J; de Bruin, S R; Baan, C A; Struijs, J N
2017-01-01
Is the simple mean of the costs per diabetes patient a suitable tool with which to compare care groups? Do the total costs of care per diabetes patient really give the best insight into care group performance? Cross-sectional, multi-level study. The 2009 insurance claims of 104,544 diabetes patients managed by care groups in the Netherlands were analysed. The data were obtained from Vektis care information centre. For each care group we determined the mean costs per patient of all the curative care and diabetes-specific hospital care using the simple mean method, then repeated it using the 'generalized linear mixed model'. We also calculated for which proportion the differences found could be attributed to the care groups themselves. The mean costs of the total curative care per patient were €3,092 - €6,546; there were no significant differences between care groups. The mixed model method resulted in less variation (€2,884 - €3,511), and there were a few significant differences. We found a similar result for diabetes-specific hospital care and the ranking position of the care groups proved to be dependent on the method used. The care group effect was limited, although it was greater in the diabetes-specific hospital costs than in the total costs of curative care (6.7% vs. 0.4%). The method used to benchmark care groups carries considerable weight. Simply stated, determining the mean costs of care (still often done) leads to an overestimation of the differences between care groups. The generalized linear mixed model is more accurate and yields better comparisons. However, the fact remains that 'total costs of care' is a faulty indicator since care groups have little impact on them. A more informative indicator is 'costs of diabetes-specific hospital care' as these costs are more influenced by care groups.
Microbial reduction of graphene oxide by Escherichia coli: a green chemistry approach.
Gurunathan, Sangiliyandi; Han, Jae Woong; Eppakayala, Vasuki; Kim, Jin-Hoi
2013-02-01
Graphene and graphene related materials are an important area of research in recent years due to their unique properties. The extensive industrial application of graphene and related compounds has led researchers to devise novel and simple methods for the synthesis of high quality graphene. In this paper, we developed an environment friendly, cost effective, simple method and green approaches for the reduction of graphene oxide (GO) using Escherichia coli biomass. In biological method, we can avoid use of toxic and environmentally harmful reducing agents commonly used in the chemical reduction of GO to obtain graphene. The biomass of E. coli reduces exfoliated GO to graphene at 37°C in an aqueous medium. The E. coli reduced graphene oxide (ERGO) was characterized with UV-visible absorption spectroscopy, particle analyzer, high resolution X-ray diffractometer, scanning electron microscopy and Raman spectroscopy. Besides the reduction potential, the biomass could also play an important role as stabilizing agent, in which synthesized graphene exhibited good stability in water. This method can open up the new avenue for preparing graphene in cost effective and large scale production. Our findings suggest that GO can be reduced by simple eco-friendly method by using E. coli biomass to produce water dispersible graphene. Copyright © 2012 Elsevier B.V. All rights reserved.
Larijani, Bagher; Arjmand, Babak; Ahmadbeigi, Naser; Falahzadeh, Khadijeh; Soleimani, Masoud; Sayahpour, Forough Azam; Aghayan, Hamid Reza
2015-11-01
Previous studies have suggested mesenchymal stem cells (MSCs) as a suitable source for cell replacement therapy in diabetes. MSCs have successfully isolated from different adult and fetal tissues, including the pancreas. In vitro studies have shown that human fetal pancreatic stem cells could be extensively expanded and differentiated into islet-like structures. Here, we introduce a simple and cost-effective method for the generation of MSCs from the human fetal pancreas (FPMSCs). To isolate FPMSCs, pancreata from four aborted fetuses (second trimester) were processed with short collagenase digestion. The resulting tissue fragments were transferred to a basic media (DMEM+15%FBS) without adding any growth factor. After 10 to14 days, fibroblast-like cells were harvested and passaged six times for further evaluations. Flow cytometry analysis and three-lineage differentiation capacity have demonstrated that these cells have MSC-like properties. We also continuously passaged samples of FPMSCs and found no evidence for chromosomal instability and morphological changes until 10th subculture. Moreover, our cell culture protocol can be easily modified and translated into a GMP-compliant one. The results of current study demonstrated that our simple and inexpensive method could yield a pure population of FPMSCs that might be suitable for transplantation.
Cost-effectiveness of cell saver in short-segment lumbar laminectomy and fusion (≤3 levels).
Kelly, Patrick D; Parker, Scott L; Mendenhall, Stephen K; Bible, Jesse E; Sivasubramaniam, Priya; Shau, David N; McGirt, Matthew J; Devin, Clinton J
2015-09-01
Mixed retrospective-prospective cohort study. To characterize practice patterns for the use of Cell Saver at our institution, investigate its cost-effectiveness, and propose a new tool for patient selection. Blood loss is an exceedingly common complication of spine surgery, and Cell Saver intraoperative cell salvage has been used to decrease reliance on allogeneic blood transfusions for blood volume replacement. The cost-effectiveness of Cell Saver has not been established for lumbar spinal surgery, and no universal guidelines exist for clinicians to decide when to utilize this tool. Other authors have proposed cutoffs for anticipated blood loss volumes which indicate that Cell Saver should be used. Five hundred and eight patients undergoing lumbar laminectomy in 3 or fewer levels were reviewed from our prospective spinal outcomes registry. Cost information for Cell Saver and allogeneic transfusions was collected from our institution's billing and collections department. Logistic regression was used to identify patient characteristics associated with use of Cell Saver. An incremental cost effectiveness ratio was calculated based on transfusion and cost data. A clinical prediction score was derived using logistic regression. Use of Cell Saver correlated with increased age, higher body mass index, diabetes, greater American Society of Anesthesiologists classification, and greater number of previous spine surgeries. Outcomes for patients who did and did not have Cell Saver set up intraoperatively were equivocal. Cell Saver was not cost effective based on current usage patterns, but may become cost effective if used for patients with high expected blood loss. A simple clinical prediction rule is proposed which may aid in selection of patients to have Cell Saver present intraoperatively. Cell Saver is not a cost-effective intervention but may become cost effective if a threshold of expected intraoperative blood loss is used to select patients more judiciously. 3.
47 CFR 76.980 - Charges for customer changes.
Code of Federal Regulations, 2012 CFR
2012-10-01
....980 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES... charge for customer changes in service tiers effected solely by coded entry on a computer terminal or by... involve more than coded entry on a computer or other similarly simple method shall be based on actual cost...
47 CFR 76.980 - Charges for customer changes.
Code of Federal Regulations, 2011 CFR
2011-10-01
....980 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES... charge for customer changes in service tiers effected solely by coded entry on a computer terminal or by... involve more than coded entry on a computer or other similarly simple method shall be based on actual cost...
47 CFR 76.980 - Charges for customer changes.
Code of Federal Regulations, 2014 CFR
2014-10-01
....980 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES... charge for customer changes in service tiers effected solely by coded entry on a computer terminal or by... involve more than coded entry on a computer or other similarly simple method shall be based on actual cost...
47 CFR 76.980 - Charges for customer changes.
Code of Federal Regulations, 2013 CFR
2013-10-01
....980 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES... charge for customer changes in service tiers effected solely by coded entry on a computer terminal or by... involve more than coded entry on a computer or other similarly simple method shall be based on actual cost...
47 CFR 76.980 - Charges for customer changes.
Code of Federal Regulations, 2010 CFR
2010-10-01
....980 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES... charge for customer changes in service tiers effected solely by coded entry on a computer terminal or by... involve more than coded entry on a computer or other similarly simple method shall be based on actual cost...
DOT National Transportation Integrated Search
1998-12-01
Biocell technology is a soil remediation technology that utilizes commercial roll-off dumpsters as simple, : yet effective bioreactors. Reported implementation costs for biocells range from $20 - $40 per cubic yard : treated. Biodegradation of some p...
On solar thermal electric power capacity sizing
NASA Astrophysics Data System (ADS)
Clark, J. S.
1984-03-01
The commercialization of parabolic dish/generator modules are investigated. Design analysis indicates that a 10 sq m/ three kilowatt generator configuration is simple and easy to maintain, manufacturing is easily adaptable, the demand is already established, the unit is cost effective and the hardware is readily available.
UPIC: Perl scripts to determine the number of SSR markers to run
USDA-ARS?s Scientific Manuscript database
We have developed Perl Scripts for the cost-effective planning of fingerprinting and genotyping experiments. The UPIC scripts detect the best combination of polymorphic simple sequence repeat (SSR) markers and provide coefficients of the amount of information obtainable (number of alleles of patter...
Electrospun ultra-fine cellulose acetate fibrous mats containing tannic acid-Fe+++ complexes
USDA-ARS?s Scientific Manuscript database
Cellulose acetate (CA) fibrous mats with improved mechanical and antioxidant properties were produced by a simple, scalable and cost-effective electrospinning method. Fibers loaded with small amounts of TA-Fe+++ complexes showed an increase in tensile strength of approximately 117% when compared to ...
Statistical methodologies for the control of dynamic remapping
NASA Technical Reports Server (NTRS)
Saltz, J. H.; Nicol, D. M.
1986-01-01
Following an initial mapping of a problem onto a multiprocessor machine or computer network, system performance often deteriorates with time. In order to maintain high performance, it may be necessary to remap the problem. The decision to remap must take into account measurements of performance deterioration, the cost of remapping, and the estimated benefits achieved by remapping. We examine the tradeoff between the costs and the benefits of remapping two qualitatively different kinds of problems. One problem assumes that performance deteriorates gradually, the other assumes that performance deteriorates suddenly. We consider a variety of policies for governing when to remap. In order to evaluate these policies, statistical models of problem behaviors are developed. Simulation results are presented which compare simple policies with computationally expensive optimal decision policies; these results demonstrate that for each problem type, the proposed simple policies are effective and robust.
Development of a simple and low cost microbioreactor for high-throughput bioprocessing.
Rahman, Pattanathu K S M; Pasirayi, Godfrey; Auger, Vincent; Ali, Zulfiqur
2009-02-01
A simple microbioreactor for high-throughput bioprocessing made from low cost polymer polytetrafluoroethylene (PTFE) tubes with a working volume of 1.5 ml is described. We have developed a microfluidic system that handles a small population of cells of a model microorganism, Pseudomonas aeruginosa DS10-129. Under the conditions of the microbioreactor, the organism produced extracellular secondary metabolites by using nutrient broth modified with glycerol. Pyocyanins were isolated from the fermented medium as a metabolite of interest. Antibiotic properties of pyocyanin were effective against a number of microorganisms such as Staphylococcus aureus, S. epidermis, Bacillus subtilis, Micrococcus luteus and Saccharomyces cerevisiae. Batch fermentation of the model organism in the microbioreactor was compared to shake-flask and conventional bench fermenter methods. Results obtained from the microbioreactor compared favourably with the conventional processes.
ERIC Educational Resources Information Center
Sawtelle, Sara
2008-01-01
Proving that technology works is not as simple as proving that a new vendor for art supplies is more cost effective. Technology effectiveness requires both the right software and the right implementation. Just having the software is not enough. Proper planning, training, leadership, support, pedagogy, and software use--along with many other…
Oral health care for pregnant and postpartum women.
Goldie, M Perno
2003-08-01
Pregnancy may pose a number of concerns to the mother and the foetus. This can include systemic and oral issues that effect health. Transmission of caries-causing bacteria is one problem that can be minimized by utilizing simple, cost-effective measures. Chlorhexidine rinses and xylitol containing chewing gum will be discussed as possible solutions to this tremendous public health problem.
ERIC Educational Resources Information Center
Ratanasiripong, Paul; Sverduk, Kevin; Hayashino, Diane; Prince, Judy
2010-01-01
The increasing prevalence of stress and anxiety on college campuses along with limited resources and budget reductions for many campuses has prompted the need for innovative approaches to help students effectively manage their stress and anxiety. With college students becoming more and more technology-savvy, the authors present an innovative…
2008-09-01
Explosives have been detected in HGR soils at levels from the low parts per billion (µg/kg) up to percent levels. RDX has been detected in leachate waters...soil are transport in surface water and subsurface transport in leachate . Simple, innovative, and cost effective technologies are being developed which...range via surface water and leachate . This technology demonstrated that application of lime is a low-cost treatment that can be incorporated into
Vehmeijer, Maarten; van Eijnatten, Maureen; Liberton, Niels; Wolff, Jan
2016-08-01
Fractures of the orbital floor are often a result of traffic accidents or interpersonal violence. To date, numerous materials and methods have been used to reconstruct the orbital floor. However, simple and cost-effective 3-dimensional (3D) printing technologies for the treatment of orbital floor fractures are still sought. This study describes a simple, precise, cost-effective method of treating orbital fractures using 3D printing technologies in combination with autologous bone. Enophthalmos and diplopia developed in a 64-year-old female patient with an orbital floor fracture. A virtual 3D model of the fracture site was generated from computed tomography images of the patient. The fracture was virtually closed using spline interpolation. Furthermore, a virtual individualized mold of the defect site was created, which was manufactured using an inkjet printer. The tangible mold was subsequently used during surgery to sculpture an individualized autologous orbital floor implant. Virtual reconstruction of the orbital floor and the resulting mold enhanced the overall accuracy and efficiency of the surgical procedure. The sculptured autologous orbital floor implant showed an excellent fit in vivo. The combination of virtual planning and 3D printing offers an accurate and cost-effective treatment method for orbital floor fractures. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Das, Roby; Sureshkumar, Sathasivam; Sreenath, Gubbi S; Kate, Vikram
2016-01-01
Comparison of Helicobacter pylori eradication rates, side effects, compliance, cost, and ulcer recurrence of sequential therapy (ST) with that of concomitant therapy (CT) in patients with perforated duodenal ulcer following simple omental patch closure. Sixty-eight patients with perforated duodenal ulcer treated with simple closure and found to be H. pylori positive on three months follow-up were randomized to receive either ST or CT for H. pylori eradication. Urease test and Giemsa stain were used to assess for H. pylori eradication status. Follow-up endoscopies were done after 3 months, 6 months, and 1 year to evaluate the ulcer recurrence. H. pylori eradication rates were similar in ST and CT groups on intention-to-treat (ITT) analysis (71.43% vs 81.80%,P = 0.40). Similar eradication rates were also found in per-protocol (PP) analysis (86.20% vs 90%,P = 0.71). Ulcer recurrence rate in ST groups and CT groups at 3 months (17.14% vs 6.06%,P = 0.26), 6 months (22.86% vs 9.09%,P = 0.19), and at 1 year (25.71% vs 15.15%,P = 0.37) of follow-up was also similar by ITT analysis. Compliance and side effects to therapies were comparable between the groups. The most common side effects were diarrhoea and metallic taste in ST and CT groups, respectively. A complete course of ST costs Indian Rupees (INR) 570.00, whereas CT costs INR 1080.00. H. pylori eradication rates, side effects, compliance, cost, and ulcer recurrences were similar between the two groups. The ST was more economical compared with CT.
Mudanyali, Onur; Tseng, Derek; Oh, Chulwoo; Isikman, Serhan O; Sencan, Ikbal; Bishara, Waheb; Oztoprak, Cetin; Seo, Sungkyu; Khademhosseini, Bahar; Ozcan, Aydogan
2010-06-07
Despite the rapid progress in optical imaging, most of the advanced microscopy modalities still require complex and costly set-ups that unfortunately limit their use beyond well equipped laboratories. In the meantime, microscopy in resource-limited settings has requirements significantly different from those encountered in advanced laboratories, and such imaging devices should be cost-effective, compact, light-weight and appropriately accurate and simple to be usable by minimally trained personnel. Furthermore, these portable microscopes should ideally be digitally integrated as part of a telemedicine network that connects various mobile health-care providers to a central laboratory or hospital. Toward this end, here we demonstrate a lensless on-chip microscope weighing approximately 46 grams with dimensions smaller than 4.2 cm x 4.2 cm x 5.8 cm that achieves sub-cellular resolution over a large field of view of approximately 24 mm(2). This compact and light-weight microscope is based on digital in-line holography and does not need any lenses, bulky optical/mechanical components or coherent sources such as lasers. Instead, it utilizes a simple light-emitting-diode (LED) and a compact opto-electronic sensor-array to record lensless holograms of the objects, which then permits rapid digital reconstruction of regular transmission or differential interference contrast (DIC) images of the objects. Because this lensless incoherent holographic microscope has orders-of-magnitude improved light collection efficiency and is very robust to mechanical misalignments it may offer a cost-effective tool especially for telemedicine applications involving various global health problems in resource limited settings.
ShareSync: A Solution for Deterministic Data Sharing over Ethernet
NASA Technical Reports Server (NTRS)
Dunn, Daniel J., II; Koons, William A.; Kennedy, Richard D.; Davis, Philip A.
2007-01-01
As part of upgrading the Contact Dynamics Simulation Laboratory (CDSL) at the NASA Marshall Space Flight Center (MSFC), a simple, cost effective method was needed to communicate data among the networked simulation machines and I/O controllers used to run the facility. To fill this need and similar applicable situations, a generic protocol was developed, called ShareSync. ShareSync is a lightweight, real-time, publish-subscribe Ethernet protocol for simple and deterministic data sharing across diverse machines and operating systems. ShareSync provides a simple Application Programming Interface (API) for simulation programmers to incorporate into their code. The protocol is compatible with virtually all Ethernet-capable machines, is flexible enough to support a variety of applications, is fast enough to provide soft real-time determinism, and is a low-cost resource for distributed simulation development, deployment, and maintenance. The first design cycle iteration of ShareSync has been completed, and the protocol has undergone several testing procedures including endurance and benchmarking tests and approaches the 2001ts data synchronization design goal for the CDSL.
Vernon, John A; Hughen, W Keener; Johnson, Scott J
2005-05-01
In the face of significant real healthcare cost inflation, pressured budgets, and ongoing launches of myriad technology of uncertain value, payers have formalized new valuation techniques that represent a barrier to entry for drugs. Cost-effectiveness analysis predominates among these methods, which involves differencing a new technological intervention's marginal costs and benefits with a comparator's, and comparing the resulting ratio to a payer's willingness-to-pay threshold. In this paper we describe how firms are able to model the feasible range of future product prices when making in-licensing and developmental Go/No-Go decisions by considering payers' use of the cost-effectiveness method. We illustrate this analytic method with a simple deterministic example and then incorporate stochastic assumptions using both analytic and simulation methods. Using this strategic approach, firms may reduce product development and in-licensing risk.
Estimation of surface temperature in remote pollution measurement experiments
NASA Technical Reports Server (NTRS)
Gupta, S. K.; Tiwari, S. N.
1978-01-01
A simple algorithm has been developed for estimating the actual surface temperature by applying corrections to the effective brightness temperature measured by radiometers mounted on remote sensing platforms. Corrections to effective brightness temperature are computed using an accurate radiative transfer model for the 'basic atmosphere' and several modifications of this caused by deviations of the various atmospheric and surface parameters from their base model values. Model calculations are employed to establish simple analytical relations between the deviations of these parameters and the additional temperature corrections required to compensate for them. Effects of simultaneous variation of two parameters are also examined. Use of these analytical relations instead of detailed radiative transfer calculations for routine data analysis results in a severalfold reduction in computation costs.
Open vs Laparoscopic Simple Prostatectomy: A Comparison of Initial Outcomes and Cost.
Demir, Aslan; Günseren, Kadir Ömür; Kordan, Yakup; Yavaşçaoğlu, İsmet; Vuruşkan, Berna Aytaç; Vuruşkan, Hakan
2016-08-01
We compared the cost-effectiveness of laparoscopic simple prostatectomy (LSP) vs open prostatectomy (OP). A total of 73 men treated for benign prostatic hyperplasia were enrolled for OP and LSP in groups 1 and 2, respectively. The findings were recorded perioperative, including operation time (OT), blood lost, transfusion rate, conversion to the open surgery, and the complications according to the Clavien Classification. The postoperative findings, including catheterization and drainage time, the amount of analgesic used, hospitalization time, postoperative complications, international prostate symptom score (IPSS) and International Index of Erectile Function (IIEF) scores, the extracted prostate weight, the uroflowmeter, as well as postvoiding residual (PVR) and quality of life (QoL) score at the postoperative third month, were analyzed. The cost of both techniques was also compared statistically. No statistical differences were found in the preoperative parameters, including age, IPSS and QoL score, maximum flow rate (Qmax), PVR, IIEF score, and prostate volumes, as measured by transabdominal ultrasonography. No statistical differences were established in terms of the OT and the weight of the extracted prostate. No differences were established with regard to complications according to Clavien's classification in groups. However, the bleeding rate was significantly lower in group 2. The drainage, catheterization, and hospitalization times and the amount of analgesics were significantly lower in the second group. The postoperative third month findings were not different statistically. Only the Qmax values were significantly greater in group 2. While there was only a $52 difference between groups with regard to operation cost, this difference was significantly different. The use of LSP for the prostates over 80 g is more effective than the OP in terms of OT, bleeding amount, transfusion rates, catheterization time, drain removal time, hospitalization time, consumed analgesic amount, and Qmax values. On the other hand, the mean cost of the LSP is higher than OP. Better effectiveness comes with higher cost.
Measurement of Antenna Bore-Sight Gain
NASA Technical Reports Server (NTRS)
Fortinberry, Jarrod; Shumpert, Thomas
2016-01-01
The absolute or free-field gain of a simple antenna can be approximated using standard antenna theory formulae or for a more accurate prediction, numerical methods may be employed to solve for antenna parameters including gain. Both of these methods will result in relatively reasonable estimates but in practice antenna gain is usually verified and documented via measurements and calibration. In this paper, a relatively simple and low-cost, yet effective means of determining the bore-sight free-field gain of a VHF/UHF antenna is proposed by using the Brewster angle relationship.
New Approaches to Data Acquisitions in a Torsion Pendulum Experiment
ERIC Educational Resources Information Center
Jiang, Daya; Xiao, Jinghua; Li, Haihong; Dai, Qionglin
2007-01-01
In this paper, two simple non-contact and cost-effective methods to acquire data in the student laboratory are applied to investigate the motion of a torsion pendulum. The first method is based on a Hall sensor, while the second makes use of an optical mouse.
Measurement of gaseous PAHs with an innovative passive sampler in community exposure studies
A sensitive, simple, and cost-effective passive sampling methodology was developed to quantify gaseous polycyclic aromatic hydrocarbons (PAHs) in personal, indoor and outdoor air. A Fan-Lioy passive PAH sampler (FL-PPS) is constructed from four 80 sections of 1 cm long SPB-5 GC c...
USDA-ARS?s Scientific Manuscript database
The advent of next-generation sequencing technologies has been a boon to the cost-effective development of molecular markers, particularly in non-model species. Here, we demonstrate the efficiency of microsatellite or simple sequence repeat (SSR) marker development from short-read sequences using th...
DESIGN MANUAL - REMOVAL OF ARSENIC FROM DRINKING WATER SUPPLIES BY ION EXCHANGE
This design manual is an in-depth presentation of the steps required to design and operate a water treatment plant for removal of excess arsenic from drinking water using the anion exchange process. The treatment process is very reliable, simple and cost-effective. This design ...
DESIGN MANUAL - REMOVAL OF ARSENIC FROM DRINKING WATER SUPPLIES BY ADSORPTIVE MEDIA
This design manual is an in-depth presentation of the steps required to design and operate a water treatment plant for removal of excess arsenic from drinking water using the adsorptive media process. The treatment process is very reliable, simple and cost-effective. The adsorpt...
A simple, cost-effective method is described for the analysis of polybrominated diphenyl ethers (PBDEs) in house dust using pressurized fluid extraction, cleanup with modified silica solid phase extraction tubes, and fluorinated internal standards. There are 14 PBDE congeners inc...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ian Metzger, Jesse Dean
2010-12-31
This software requires inputs of simple water fixture inventory information and calculates the water/energy and cost benefits of various retrofit opportunities. This tool includes water conservation measures for: Low-flow Toilets, Low-flow Urinals, Low-flow Faucets, and Low-flow Showheads. This tool calculates water savings, energy savings, demand reduction, cost savings, and building life cycle costs including: simple payback, discounted payback, net-present value, and savings to investment ratio. In addition this tool also displays the environmental benefits of a project.
Lalić, Nebojša; Russel-Szymczyk, Monika; Culic, Marina; Tikkanen, Christian Klyver; Chubb, Barrie
2018-04-26
This study investigates the cost-effectiveness of insulin degludec versus insulin glargine U100 in patients with type 1 and type 2 diabetes mellitus in Serbia. A cost-utility analysis, implementing a simple short-term model, was used to compare treatment costs and outcomes with degludec versus glargine U100 in patients with type 1 (T1DM) and type 2 diabetes (T2DM). Cost-effectiveness was analysed in a 1-year setting, based on data from clinical trials. Costs were estimated from the healthcare payer perspective, the Serbian Health Insurance Fund (RFZO). The outcome measure was the incremental cost-effectiveness ratio (ICER) or cost per quality-adjusted life-year (QALY) gained. Degludec is highly cost-effective compared with glargine U100 for people with T1DM and T2DM in Serbia. The ICERs are estimated at 417,586 RSD/QALY gained in T1DM, 558,811 RSD/QALY gained in T2DM on basal oral therapy (T2DM BOT ) and 1,200,141 RSD/QALY gained in T2DM on basal-bolus therapy (T2DM B/B ). All ICERs fall below the commonly accepted thresholds for cost-effectiveness in Serbia (1,785,642 RSD/QALY gained). In all three patient groups, insulin costs are higher with degludec than with glargine U100, but these costs are partially offset by savings from a lower daily insulin dose in T1DM and T2DM BOT , a reduction in hypoglycaemic events in all three patient groups and reduced costs of SMBG testing in the T2DM groups with degludec versus glargine U100. Degludec is a cost-effective alternative to glargine U100 for patients with T1DM and T2DM in Serbia. Degludec may particularly benefit those suffering from hypoglycaemia or where the patient would benefit from the option of flexible dosing. Novo Nordisk.
NASA Astrophysics Data System (ADS)
Gholami, Mehrdad; Behkami, Shima; Zain, Sharifuddin Md.; Bakirdere, Sezgin
2016-11-01
The objective of this work is to prepare a cost-effective, low reagent consumption and high performance polytetrafluoroethylene (PTFE) vessel that is capable to work in domestic microwave for digesting food and environmental samples. The designed vessel has a relatively thicker wall compared to that of commercial vessels. In this design, eight vessels are placed in an acrylonitrile butadiene styrene (ABS) holder to keep them safe and stable. This vessel needs only 2.0 mL of HNO3 and 1.0 mL H2O2 to digest 100 mg of biological sample. The performance of this design is then evaluated with an ICP-MS instrument in the analysis of the several NIST standard reference material of milk 1849a, rice flour 1568b, spinach leave 1570a and Peach Leaves 1547 in a domestic microwave oven with inverter technology. Outstanding agreement to (SRM) values are observed by using the suggested power to time microwave program, which simulates the reflux action occurring in this closed vessel. Taking into account the high cost of commercial microwave vessels and the volume of chemicals needed for various experiments (8-10 mL), this simple vessel is cost effective and suitable for digesting food and environmental samples.
Tian, Kun; Siegel, Gene; Tiwari, Ashutosh
2017-02-01
The development of simple and cost-effective methods for the detection and treatment of Hg 2+ in the environment is an important area of research due to the serious health risk that Hg 2+ poses to humans. Colorimetric sensing based on the induced aggregation of nanoparticles is of great interest since it offers a low cost, simple, and relatively rapid procedure, making it perfect for on-site analysis. Herein we report the development of a simple colorimetric sensor for the selective detection and estimation of mercury ions in water, based on chitosan stabilized gold nanoparticles (AuNPs) and 2,6-pyridinedicarboxylic acid (PDA). In the presence of Hg 2+ , PDA induces the aggregation of AuNPs, causing the solution to change colors varying from red to blue, depending on the concentration of Hg 2+ . The formation of aggregated AuNPs in the presence of Hg 2+ was confirmed using transmission electron microscopy (TEM) and UV-Vis spectroscopy. The method exhibits linearity in the range of 300nM to 5μM and shows excellent selectivity towards Hg 2+ among seventeen different metal ions and was successfully applied for the detection of Hg 2+ in spiked river water samples. The developed technique is simple and superior to the existing techniques in that it allows detection of Hg 2+ using the naked eye and simple and rapid colorimetric analysis, which eliminates the need for sophisticated instruments and sample preparation methods. Copyright © 2016 Elsevier B.V. All rights reserved.
Organizing for low cost space operations - Status and plans
NASA Technical Reports Server (NTRS)
Lee, C.
1976-01-01
Design features of the Space Transportation System (vehicle reuse, low cost expendable components, simple payload interfaces, standard support systems) must be matched by economical operational methods to achieve low operating and payload costs. Users will be responsible for their own payloads and will be charged according to the services they require. Efficient use of manpower, simple documentation, simplified test, checkout, and flight planning are firm goals, together with flexibility for quick response to varying user needs. Status of the Shuttle hardware, plans for establishing low cost procedures, and the policy for user charges are discussed.
NASA Astrophysics Data System (ADS)
John, Christopher; Spura, Thomas; Habershon, Scott; Kühne, Thomas D.
2016-04-01
We present a simple and accurate computational method which facilitates ab initio path-integral molecular dynamics simulations, where the quantum-mechanical nature of the nuclei is explicitly taken into account, at essentially no additional computational cost in comparison to the corresponding calculation using classical nuclei. The predictive power of the proposed quantum ring-polymer contraction method is demonstrated by computing various static and dynamic properties of liquid water at ambient conditions using density functional theory. This development will enable routine inclusion of nuclear quantum effects in ab initio molecular dynamics simulations of condensed-phase systems.
NASA Technical Reports Server (NTRS)
Torres-Pomales, Wilfredo
2015-01-01
This report documents a case study on the application of Reliability Engineering techniques to achieve an optimal balance between performance and robustness by tuning the functional parameters of a complex non-linear control system. For complex systems with intricate and non-linear patterns of interaction between system components, analytical derivation of a mathematical model of system performance and robustness in terms of functional parameters may not be feasible or cost-effective. The demonstrated approach is simple, structured, effective, repeatable, and cost and time efficient. This general approach is suitable for a wide range of systems.
NASA Technical Reports Server (NTRS)
Sterk, Steve; Chesley, Stephan
2008-01-01
The upcoming retirement of the Baby Boomers will leave a workforce age gap between the younger generation (the future NASA decision makers) and the gray beards. This paper will reflect on the average age of the workforce across NASA Centers, the Aerospace Industry and other Government Agencies, like DoD. This paper will dig into Productivity and Realization Factors and how they get applied to bi-monthly (payroll) data for true full-time equivalent (FTE) calculations that could be used at each of the NASA Centers and other business systems that are on the forefront in being implemented. This paper offers some comparative costs analysis/solutions, from simple FTE cost-estimating relationships (CERs) versus CERs for monthly time-phasing activities for small research projects that start and get completed within a government fiscal year. This paper will present the results of a parametric study investigating the cost-effectiveness of alternative performance-based CERs and how they get applied into the Center's forward pricing rate proposals (FPRP). True CERs based on the relationship of a younger aged workforce will have some effects on labor rates used in both commercial cost models and other internal home-grown cost models which may impact the productivity factors for future NASA missions.
Upstream solutions to coral reef conservation: The payoffs of smart and cooperative decision-making.
Oleson, Kirsten L L; Falinski, Kim A; Lecky, Joey; Rowe, Clara; Kappel, Carrie V; Selkoe, Kimberly A; White, Crow
2017-04-15
Land-based source pollutants (LBSP) actively threaten coral reef ecosystems globally. To achieve the greatest conservation outcome at the lowest cost, managers could benefit from appropriate tools that evaluate the benefits (in terms of LBSP reduction) and costs of implementing alternative land management strategies. Here we use a spatially explicit predictive model (InVEST-SDR) that quantifies change in sediment reaching the coast for evaluating the costs and benefits of alternative threat-abatement scenarios. We specifically use the model to examine trade-offs among possible agricultural road repair management actions (water bars to divert runoff and gravel to protect the road surface) across the landscape in West Maui, Hawaii, USA. We investigated changes in sediment delivery to coasts and costs incurred from management decision-making that is (1) cooperative or independent among landowners, and focused on (2) minimizing costs, reducing sediment, or both. The results illuminate which management scenarios most effectively minimize sediment while also minimizing the cost of mitigation efforts. We find targeting specific "hotspots" within all individual parcels is more cost-effective than targeting all road segments. The best outcomes are achieved when landowners cooperate and target cost-effective road repairs, however, a cooperative strategy can be counter-productive in some instances when cost-effectiveness is ignored. Simple models, such as the one developed here, have the potential to help managers make better choices about how to use limited resources. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Algal biofuels: challenges and opportunities.
Leite, Gustavo B; Abdelaziz, Ahmed E M; Hallenbeck, Patrick C
2013-10-01
Biodiesel production using microalgae is attractive in a number of respects. Here a number of pros and cons to using microalgae for biofuels production are reviewed. Algal cultivation can be carried out using non-arable land and non-potable water with simple nutrient supply. In addition, algal biomass productivities are much higher than those of vascular plants and the extractable content of lipids that can be usefully converted to biodiesel, triacylglycerols (TAGs) can be much higher than that of the oil seeds now used for first generation biodiesel. On the other hand, practical, cost-effective production of biofuels from microalgae requires that a number of obstacles be overcome. These include the development of low-cost, effective growth systems, efficient and energy saving harvesting techniques, and methods for oil extraction and conversion that are environmentally benign and cost-effective. Promising recent advances in these areas are highlighted. Copyright © 2013 Elsevier Ltd. All rights reserved.
Artificial neural networks using complex numbers and phase encoded weights.
Michel, Howard E; Awwal, Abdul Ahad S
2010-04-01
The model of a simple perceptron using phase-encoded inputs and complex-valued weights is proposed. The aggregation function, activation function, and learning rule for the proposed neuron are derived and applied to Boolean logic functions and simple computer vision tasks. The complex-valued neuron (CVN) is shown to be superior to traditional perceptrons. An improvement of 135% over the theoretical maximum of 104 linearly separable problems (of three variables) solvable by conventional perceptrons is achieved without additional logic, neuron stages, or higher order terms such as those required in polynomial logic gates. The application of CVN in distortion invariant character recognition and image segmentation is demonstrated. Implementation details are discussed, and the CVN is shown to be very attractive for optical implementation since optical computations are naturally complex. The cost of the CVN is less in all cases than the traditional neuron when implemented optically. Therefore, all the benefits of the CVN can be obtained without additional cost. However, on those implementations dependent on standard serial computers, CVN will be more cost effective only in those applications where its increased power can offset the requirement for additional neurons.
Sardiwalla, Yaeesh; Jufas, Nicholas; Morris, David P
2017-06-12
Minimally Invasive Ponto Surgery (MIPS) was recently described as a new technique to facilitate the placement of percutaneous bone anchored hearing devices. The procedure has resulted in a simplification of the surgical steps and a dramatic reduction in surgical time while maintaining excellent patient outcomes. Given these developments, our group sought to move the procedure from the main operating suite where they have traditionally been performed. This study aims to test the null hypothesis that MIPS and open approaches have the same direct costs for the implantation of percutaneous bone anchored hearing devices in a Canadian public hospital setting. A retrospective direct cost comparison of MIPS and open approaches for the implantation of bone conduction implants was conducted. Indirect and future costs were not included in the fiscal analysis. A simple cost comparison of the two approaches was made considering time, staff and equipment needs. All 12 operations were performed on adult patients from 2013 to 2016 by the same surgeon at a single hospital site. MIPS has a total mean reduction in cost of CAD$456.83 per operation from the hospital perspective when compared to open approaches. The average duration of the MIPS operation was 7 min, which is on average 61 min shorter compared with open approaches. The MIPS technique was more cost effective than traditional open approaches. This primarily reflects a direct consequence of a reduction in surgical time, with further contributions from reduced staffing and equipment costs. This simple, quick intervention proved to be feasible when performed outside the main operating room. A blister pack of required equipment could prove convenient and further reduce costs.
Kim, Minjin; Kim, Gi-Hwan; Oh, Kyoung Suk; Jo, Yimhyun; Yoon, Hyun; Kim, Ka-Hyun; Lee, Heon; Kim, Jin Young; Kim, Dong Suk
2017-06-27
Organic-inorganic hybrid metal halide perovskite solar cells (PSCs) are attracting tremendous research interest due to their high solar-to-electric power conversion efficiency with a high possibility of cost-effective fabrication and certified power conversion efficiency now exceeding 22%. Although many effective methods for their application have been developed over the past decade, their practical transition to large-size devices has been restricted by difficulties in achieving high performance. Here we report on the development of a simple and cost-effective production method with high-temperature and short-time annealing processing to obtain uniform, smooth, and large-size grain domains of perovskite films over large areas. With high-temperature short-time annealing at 400 °C for 4 s, the perovskite film with an average domain size of 1 μm was obtained, which resulted in fast solvent evaporation. Solar cells fabricated using this processing technique had a maximum power conversion efficiency exceeding 20% over a 0.1 cm 2 active area and 18% over a 1 cm 2 active area. We believe our approach will enable the realization of highly efficient large-area PCSs for practical development with a very simple and short-time procedure. This simple method should lead the field toward the fabrication of uniform large-scale perovskite films, which are necessary for the production of high-efficiency solar cells that may also be applicable to several other material systems for more widespread practical deployment.
A simple and low-cost permanent magnet system for NMR
NASA Astrophysics Data System (ADS)
Chonlathep, K.; Sakamoto, T.; Sugahara, K.; Kondo, Y.
2017-02-01
We have developed a simple, easy to build, and low-cost magnet system for NMR, of which homogeneity is about 4 ×10-4 at 57 mT, with a pair of two commercially available ferrite magnets. This homogeneity corresponds to about 90 Hz spectral resolution at 2.45 MHz of the hydrogen Larmor frequency. The material cost of this NMR magnet system is little more than 100. The components can be printed by a 3D printer.
Dong, Hengjin; Buxton, Martin
2006-01-01
The objective of this study is to apply a Markov model to compare cost-effectiveness of total knee replacement (TKR) using computer-assisted surgery (CAS) with that of TKR using a conventional manual method in the absence of formal clinical trial evidence. A structured search was carried out to identify evidence relating to the clinical outcome, cost, and effectiveness of TKR. Nine Markov states were identified based on the progress of the disease after TKR. Effectiveness was expressed by quality-adjusted life years (QALYs). The simulation was carried out initially for 120 cycles of a month each, starting with 1,000 TKRs. A discount rate of 3.5 percent was used for both cost and effectiveness in the incremental cost-effectiveness analysis. Then, a probabilistic sensitivity analysis was carried out using a Monte Carlo approach with 10,000 iterations. Computer-assisted TKR was a long-term cost-effective technology, but the QALYs gained were small. After the first 2 years, the incremental cost per QALY of computer-assisted TKR was dominant because of cheaper and more QALYs. The incremental cost-effectiveness ratio (ICER) was sensitive to the "effect of CAS," to the CAS extra cost, and to the utility of the state "Normal health after primary TKR," but it was not sensitive to utilities of other Markov states. Both probabilistic and deterministic analyses produced similar cumulative serious or minor complication rates and complex or simple revision rates. They also produced similar ICERs. Compared with conventional TKR, computer-assisted TKR is a cost-saving technology in the long-term and may offer small additional QALYs. The "effect of CAS" is to reduce revision rates and complications through more accurate and precise alignment, and although the conclusions from the model, even when allowing for a full probabilistic analysis of uncertainty, are clear, the "effect of CAS" on the rate of revisions awaits long-term clinical evidence.
Comparative study of disinfectants for use in low-cost gravity driven household water purifiers.
Patil, Rajshree A; Kausley, Shankar B; Balkunde, Pradeep L; Malhotra, Chetan P
2013-09-01
Point-of-use (POU) gravity-driven household water purifiers have been proven to be a simple, low-cost and effective intervention for reducing the impact of waterborne diseases in developing countries. The goal of this study was to compare commonly used water disinfectants for their feasibility of adoption in low-cost POU water purifiers. The potency of each candidate disinfectant was evaluated by conducting a batch disinfection study for estimating the concentration of disinfectant needed to inactivate a given concentration of the bacterial strain Escherichia coli ATCC 11229. Based on the concentration of disinfectant required, the size, weight and cost of a model purifier employing that disinfectant were estimated. Model purifiers based on different disinfectants were compared and disinfectants which resulted in the most safe, compact and inexpensive purifiers were identified. Purifiers based on bromine, tincture iodine, calcium hypochlorite and sodium dichloroisocyanurate were found to be most efficient, cost effective and compact with replacement parts costing US$3.60-6.00 for every 3,000 L of water purified and are thus expected to present the most attractive value proposition to end users.
Coins and Costs: A Simple and Rapid Assessment of Basic Financial Knowledge
ERIC Educational Resources Information Center
Willner, Paul; Bailey, Rebecca; Dymond, Simon; Parry, Rhonwen
2011-01-01
Introduction: We describe a simple and rapid screening test for basic financial knowledge that is suitable for administration to people with mild intellectual disabilities. Method: The Coins and Costs test asks respondents to name coins, and to estimate prices of objects ranging between 1 British Pound (an ice cream) and 100K British Pounds (a…
Willingness to pay and cost of illness for changes in health capital depreciation.
Ried, W
1996-01-01
The paper investigates the relationship between the willingness to pay and the cost of illness approach with respect to the evaluation of economic burden due to adverse health effects. The basic intertemporal framework is provided by Grossman's pure investment model, while effects on individual morbidity are taken to be generated by marginal changes in the rate of health capital depreciation. More specifically, both the simple example of purely temporary changes and the more general case of persistent variations in health capital depreciation are discussed. The analysis generates two principal findings. First, for a class of identical individuals cost as measured by the cost of illness approach is demonstrated to provide a lower bound on the true welfare cost to the individual, i.e. cost as given by the willingness to pay approach. Moreover, the cost of illness is increasing in the size of the welfare loss. Second, if one takes into account the possible heterogeneity of individuals, a clear relationship between the cost values supplied by the two approaches no longer exists. As an example, the impact of variations in either financial wealth or health capital endowment is discussed. Thus, diversity in individual type turns out to blur the link between cost of illness and the true economic cost.
Jernigan, J A; Adal, K A; Anglim, A M; Byers, K E; Farr, B M
1994-12-01
In 1990, the Centers for Disease Control and Prevention recommended substituting dust-mist particulate respirators for simple isolation masks in acid-fast bacillus isolation rooms, reasoning that air leaks around the simple masks could result in a higher rate of purified protein derivative skin-test conversion. In 1993, a Centers for Disease Control and Prevention draft guideline proposed that high-efficiency particulate air filter respirators be used instead of dust-mist particulate respirators. Epidemiologic data were not available to assess the importance of these changes or their cost-effectiveness. The University of Virginia was affiliated with a tuberculosis hospital from 1979 until 1987. We surveyed physicians who had served as residents in internal medicine during this period regarding purified protein derivative skin-test history. duration of work at the tuberculosis sanatorium, and any history of unprotected exposures to patients with active pulmonary or laryngeal tuberculosis. Patients with active tuberculosis at the sanatorium were isolated in negative-pressure rooms with UV lights. Physicians wore simple isolation masks in these rooms. Responses were received from 83 former resident physicians. Fifty-two physicians had worked on the tuberculosis wards for a total of 420 weeks, with no subsequent skin-test conversions (95% CI 0 to 1 conversion/8 physician-years). These data document a low risk of occupational transmission of Mycobacterium tuberculosis to physicians who wear simple isolation masks in negative-pressure ventilation rooms with UV lights. This low rate predicts that the additional protective efficacy and cost-effectiveness of the more expensive high-efficiency particulate air filter respirators and the respiratory protection program will be low.
Cai, Longfei; Zhong, Minghua; Li, Huolin; Xu, Chunxiu; Yuan, Biyu
2015-07-01
We describe a simple and cost-effective strategy for rapid fabrication of microfluidic paper-based analytical devices and valves by inkjet printing. NaOH aqueous solution was printed onto a hydrophobic filter paper, which was previously obtained by soaking in a trimethoxyoctadecylsilane-heptane solution, allowing selective wet etching of hydrophobic cellulose to create hydrophilic-hydrophobic contrast with a relatively good resolution. Hexadecyltrimethylammonium bromide (CTMAB)-ethanol solution was printed onto hydrophobic paper to fabricate temperature-controlled valves. At low temperature, CTMAB deposited on the paper is insoluble in aqueous fluid, thus the paper remains hydrophobic. At high temperature, CTMAB becomes soluble so the CTMAB-deposited channel becomes hydrophilic, allowing the wicking of aqueous solution through the valve. We believe that this strategy will be very attractive for the development of simple micro analytical devices for point-of-care applications, including diagnostic testing, food safety control, and environmental monitoring.
Efficient Jacobian inversion for the control of simple robot manipulators
NASA Technical Reports Server (NTRS)
Fijany, Amir; Bejczy, Antal K.
1988-01-01
Symbolic inversion of the Jacobian matrix for spherical wrist arms is investigated. It is shown that, taking advantage of the simple geometry of these arms, the closed-form solution of the system Q = J-1X, representing a transformation from task space to joint space, can be obtained very efficiently. The solutions for PUMA, Stanford, and a six-revolute-joint coplanar arm, along with all singular points, are presented. The solution for each joint variable is found as an explicit function of the singular points which provides a better insight into the effect of different singular points on the motion and force exertion of each individual joint. For the above arms, the computation cost of the solution is on the same order as the cost of forward kinematic solution and it is significantly reduced if forward kinematic solution is already obtained. A comparison with previous methods shows that this method is the most efficient to date.
Williamson, Mark; Sehjal, Ranjit; Jones, Mark; James, Chris; Smith, Andrew
2018-01-01
With today’s National Health Service (NHS) facing huge financial pressures the healthcare profession cannot afford to carry on spending at the current rate. Individual clinicians should be encouraged to critically appraise their own practices to bring about a more efficient and cost-effective service. The purpose of this project was to analyse the way that carpal tunnel surgery was being performed within our institution and bring about safe changes to practice that reduce expenditure. By critiquing our practices and applying simple changes based around sound evidence an annual saving of over £15 500 to the department was made. The changes instigated are simple, sustainable and safe to implement while providing improved patient satisfaction. They are also easily transferrable across institutions and to other minor hand surgical procedures to afford even greater ongoing savings to the NHS. PMID:29946571
Williamson, Mark; Sehjal, Ranjit; Jones, Mark; James, Chris; Smith, Andrew
2018-01-01
With today's National Health Service (NHS) facing huge financial pressures the healthcare profession cannot afford to carry on spending at the current rate. Individual clinicians should be encouraged to critically appraise their own practices to bring about a more efficient and cost-effective service. The purpose of this project was to analyse the way that carpal tunnel surgery was being performed within our institution and bring about safe changes to practice that reduce expenditure. By critiquing our practices and applying simple changes based around sound evidence an annual saving of over £15 500 to the department was made. The changes instigated are simple, sustainable and safe to implement while providing improved patient satisfaction. They are also easily transferrable across institutions and to other minor hand surgical procedures to afford even greater ongoing savings to the NHS.
Schmidt, James R.; Liefooghe, Baptist
2016-01-01
This report presents data from two versions of the task switching procedure in which the separate influence of stimulus repetitions, response key repetitions, conceptual response repetitions, cue repetitions, task repetitions, and congruency are considered. Experiment 1 used a simple alternating runs procedure with parity judgments of digits and consonant/vowel decisions of letters as the two tasks. Results revealed sizable effects of stimulus and response repetitions, and controlling for these effects reduced the switch cost. Experiment 2 was a cued version of the task switch paradigm with parity and magnitude judgments of digits as the two tasks. Results again revealed large effects of stimulus and response repetitions, in addition to cue repetition effects. Controlling for these effects again reduced the switch cost. Congruency did not interact with our novel “unbiased” measure of switch costs. We discuss how the task switch paradigm might be thought of as a more complex version of the feature integration paradigm and propose an episodic learning account of the effect. We further consider to what extent appeals to higher-order control processes might be unnecessary and propose that controls for feature integration biases should be standard practice in task switching experiments. PMID:26964102
NASA Technical Reports Server (NTRS)
Sterk, Steve; Chesley, Stephen
2008-01-01
The upcoming retirement of the Baby Boomers on the horizon will leave a performance gap between younger generation (the future NASA decision makers) and the gray beards. This paper will reflect on the average age of workforce across NASA Centers, the Aerospace Industry and other Government Agencies, like DoD. This papers will dig into Productivity and Realization Factors and how they get applied to bimonthly (payroll data) for true FTE calculations that could be used at each of the NASA Centers and other business systems that are on the forefront in being implemented. This paper offers some comparative costs solutions, from simple - full time equivalent (FTE) cost estimating relationships CERs, to complex - CERs for monthly time-phasing activities for small research projects that start and get completed within a government fiscal year. This paper will present the results of a parametric study investigating the cost-effectiveness of different alternatives performance based cost estimating relationships (CERs) and how they get applied into the Center s forward pricing rate proposals (FPRP). True CERs based on the relationship of a younger aged workforce will have some effects on labor rates used in both commercial cost models and internal home-grown cost models which may impact the productivity factors for future NASA missions.
Kahn, James G.; Jiwani, Aliya; Gomez, Gabriela B.; Hawkes, Sarah J.; Chesson, Harrell W.; Broutet, Nathalie; Kamb, Mary L.; Newman, Lori M.
2014-01-01
Background Syphilis in pregnancy imposes a significant global health and economic burden. More than half of cases result in serious adverse events, including infant mortality and infection. The annual global burden from mother-to-child transmission (MTCT) of syphilis is estimated at 3.6 million disability-adjusted life years (DALYs) and $309 million in medical costs. Syphilis screening and treatment is simple, effective, and affordable, yet, worldwide, most pregnant women do not receive these services. We assessed cost-effectiveness of scaling-up syphilis screening and treatment in existing antenatal care (ANC) programs in various programmatic, epidemiologic, and economic contexts. Methods and Findings We modeled the cost, health impact, and cost-effectiveness of expanded syphilis screening and treatment in ANC, compared to current services, for 1,000,000 pregnancies per year over four years. We defined eight generic country scenarios by systematically varying three factors: current maternal syphilis testing and treatment coverage, syphilis prevalence in pregnant women, and the cost of healthcare. We calculated program and net costs, DALYs averted, and net costs per DALY averted over four years in each scenario. Program costs are estimated at $4,142,287 – $8,235,796 per million pregnant women (2010 USD). Net costs, adjusted for averted medical care and current services, range from net savings of $12,261,250 to net costs of $1,736,807. The program averts an estimated 5,754 – 93,484 DALYs, yielding net savings in four scenarios, and a cost per DALY averted of $24 – $111 in the four scenarios with net costs. Results were robust in sensitivity analyses. Conclusions Eliminating MTCT of syphilis through expanded screening and treatment in ANC is likely to be highly cost-effective by WHO-defined thresholds in a wide range of settings. Countries with high prevalence, low current service coverage, and high healthcare cost would benefit most. Future analyses can be tailored to countries using local epidemiologic and programmatic data. PMID:24489931
NASA Astrophysics Data System (ADS)
Phumying, Santi; Labauyai, Sarawut; Chareonboon, Wirat; Phokha, Sumalin; Maensiri, Santi
2015-06-01
In this paper, we report on the optical properties of gallium oxide (β-Ga2O3) nanorods synthesized by a simple, cost-effective and environment-friendly method using gallium(III) nitrate hydrate and freshly extracted egg white (ovalbumin) in an aqueous medium. The extracted egg white acted as a matrix for the entrapment of gallium ions to generate a gelled precursor. The structure of the prepared samples was studied by X-ray diffraction and Raman spectroscopy to confirm the formation of β-Ga2O3 with a monoclinic structure after calcination of the precursor in air at 750, 850, and 950 °C for 3 h. Scanning electron microscopy images revealed the morphology and formation of nanorods with different sizes and shapes in the samples, resulting from the effect of the calcination temperature. All the samples showed a strong UV absorption with the band gap in the range of 3.87-3.97 eV. Room-temperature photoluminescence spectra of all the samples also showed a strong UV emission. The UV emission results were discussed based on the basis of charge recombination.
Managing Early Childhood Caries for Young Children in China.
Chen, Kitty Jieyi; Gao, Sherry Shiqian; Duangthip, Duangporn; Lo, Edward Chin Man; Chu, Chun Hung
2018-01-30
The latest national survey found that 70% of 5-year-old children in China had dental caries. The prevalence of early childhood caries (ECC) may not only be attributed to poor oral hygiene and unhealthy diet, but also to limited access to and availability of dental care. The prevailing preventive measures adopted by industrialised countries for ECC management are neither practical nor affordable in China. Hence, an alternative approach to ECC management is necessary. Atraumatic restorative treatment (ART) has been advocated because the simple and short operative time renders ART affordable. However, the success rate of ART in restoring anterior primary teeth is unfavourable. Although there is no water fluoridation in China, topical fluorides may be used to manage ECC. Tooth brushing with fluoride toothpaste is effective for caries control, but not all toothpastes in China are fluoridated. Professionally applied fluorides such as sodium fluoride varnish can be a cost-effective treatment for managing the high prevalence of ECC in China. Silver diamine fluoride (SDF) at 38% is suggested to be effective in arresting ECC in China. It can be a simple, non-invasive and low-cost treatment. However, it stains caries black. Children and their parents must be well informed before SDF treatment.
Managing Early Childhood Caries for Young Children in China
Chen, Kitty Jieyi; Duangthip, Duangporn; Lo, Edward Chin Man
2018-01-01
The latest national survey found that 70% of 5-year-old children in China had dental caries. The prevalence of early childhood caries (ECC) may not only be attributed to poor oral hygiene and unhealthy diet, but also to limited access to and availability of dental care. The prevailing preventive measures adopted by industrialised countries for ECC management are neither practical nor affordable in China. Hence, an alternative approach to ECC management is necessary. Atraumatic restorative treatment (ART) has been advocated because the simple and short operative time renders ART affordable. However, the success rate of ART in restoring anterior primary teeth is unfavourable. Although there is no water fluoridation in China, topical fluorides may be used to manage ECC. Tooth brushing with fluoride toothpaste is effective for caries control, but not all toothpastes in China are fluoridated. Professionally applied fluorides such as sodium fluoride varnish can be a cost-effective treatment for managing the high prevalence of ECC in China. Silver diamine fluoride (SDF) at 38% is suggested to be effective in arresting ECC in China. It can be a simple, non-invasive and low-cost treatment. However, it stains caries black. Children and their parents must be well informed before SDF treatment. PMID:29385684
The Good Behavior Game: a best practice candidate as a universal behavioral vaccine.
Embry, Dennis D
2002-12-01
A "behavioral vaccine" provides an inoculation against morbidity or mortality, impacting physical, mental, or behavior disorders. An historical example of a behavioral vaccine is antiseptic hand washing to reduce childbed fever. In current society, issues with high levels of morbidity, such as substance abuse, delinquency, youth violence, and other behavioral disorders (multiproblems), cry out for a low-cost, widespread strategy as simple as antiseptic hand washing. Congruent research findings from longitudinal studies, twin studies, and other investigations suggest that a possibility might exist for a behavioral vaccine for multiproblem behavior. A simple behavioral strategy called the Good Behavior Game (GBG), which reinforces inhibition in a group context of elementary school, has substantial previous research to consider its use as a behavioral vaccine. The GBG is not a curriculum but rather a simple behavioral procedure from applied behavior analysis. Approximately 20 independent replications of the GBG across different grade levels, different types of students, different settings, and some with long-term follow-up show strong, consistent impact on impulsive, disruptive behaviors of children and teens as well as reductions in substance use or serious antisocial behaviors. The GBG, named as a "best practice" for the prevention of substance abuse or violent behavior by a number of federal agencies, is unique because it is the only practice implemented by individual teachers that is documented to have long-term effects. Presently, the GBG is only used in a small number of settings. However, near universal use of the GBG, in major political jurisdictions during the elementary years, could substantially reduce the incidence of substance use, antisocial behavior, and other adverse developmental or social consequences at a very modest cost, with very positive cost-effectiveness ratios.
Kapoor, Ritika; Martinez-Vega, Rosario; Dong, Di; Tan, Sharlene Yanying; Leo, Yee-Sin; Lee, Cheng-Chuan; Sung, Cynthia; Ng, Oon-Tek; Archuleta, Sophia; Teo, Yik-Ying
2015-02-01
Abacavir (ABC) is one of the more affordable antiretroviral drugs used for controlling HIV. Although with similar efficacy to current first-line drugs, its limited usage in Singapore can be attributed to its possible side effect of adverse hypersensitivity reactions (HSRs). HLA-B*5701 genotyping is a clinically relevant procedure for avoiding abacavir-induced HSRs. As patients who do not carry the risk allele are unlikely to develop HSRs, a simple rule can be developed to allow abacavir prescription for patients who are B*5701 negative. Here, we carry out a cost-effectiveness analysis of HLA-B*5701 genotyping before abacavir prescription in the context of the Singapore healthcare system, which caters predominantly to Han Chinese, Southeast-asian Malays, and South-asian Indians. In addition, we aim to identify the most cost-effective treatment regimen for HIV patients. A decision tree model was developed in TreeAge. The model considers medical treatment and genotyping costs, genotyping test characteristics, the prevalence of the risk allele, reduction in the quality of life, and increased expenditure due to side effects and other factors, evaluating independently over early-stage and late-stage HIV patients segmented by drug contraindications. The study indicates that genotyping is not cost-effective for any ethnicity irrespective of the disease stage, except for Indian patients with early-stage HIV who are contraindicated to tenofovir. Abacavir (as first-line) without genotyping is the cheapest and most cost-effective treatment for all ethnicities except for early-stage Indian HIV patients contraindicated to tenofovir. The HLA-B*5701 frequency, the mortality rate from abacavir-induced HSRs, and genotyping costs are among the major factors influencing the cost-effectiveness.
Liu, I-Chen; Chen, Pin-Chuan; Chau, Lai-Kwan; Chang, Guo-En
2018-01-08
We propose and develop an intensity-detection-based refractive-index (RI) sensor for low-cost, rapid RI sensing. The sensor is composed of a polymer bent ridge waveguide (BRWG) structure on a low-cost glass substrate and is integrated with a microfluidic channel. Different-RI solutions flowing through the BRWG sensing region induce output optical power variations caused by optical bend losses, enabling simple and real-time RI detection. Additionally, the sensors are fabricated using rapid and cost-effective vacuum-less processes, attaining the low cost and high throughput required for mass production. A good RI solution of 5.31 10 -4 × RIU -1 is achieved from the RI experiments. This study demonstrates mass-producible and compact RI sensors for rapid and sensitive chemical analysis and biomedical sensing.
ERIC Educational Resources Information Center
Alkilany, Alaaldin M.; Mansour, Sara; Amro, Hamza M.; Pelaz, Beatriz; Soliman, Mahmoud G.; Hinman, Joshua G.; Dennison, Jordan M.; Parak, Wolfgang J.; Murphy, Catherine J.
2017-01-01
A simple, reliable, and cost-effective experiment is presented in which students synthesized citrate-capped gold nanoparticles (GNPs), functionalized them with poly(ethylene glycol) (PEG), and transferred the PEG-GNPs from water to the organic phase dichloromethane. The experiment introduces students to nanotechnology with foci on important…
A Controlled Drug-Delivery Experiment Using Alginate Beads
ERIC Educational Resources Information Center
Farrell, Stephanie; Vernengo, Jennifer
2012-01-01
This paper describes a simple, cost-effective experiment which introduces students to drug delivery and modeling using alginate beads. Students produce calcium alginate beads loaded with drug and measure the rate of release from the beads for systems having different stir rates, geometries, extents of cross-linking, and drug molecular weight.…
Climate analyses to assess risks from invasive forest insects: Simple matching to advanced models
Robert C. Venette
2017-01-01
Purpose of Review. The number of invasive alien insects that adversely affect trees and forests continues to increase as do associated ecological, economic, and sociological impacts. Prevention strategies remain the most cost-effective approach to address the issue, but risk management decisions, particularly those affecting international trade,...
DNA Extraction Techniques for Use in Education
ERIC Educational Resources Information Center
Hearn, R. P.; Arblaster, K. E.
2010-01-01
DNA extraction provides a hands-on introduction to DNA and enables students to gain real life experience and practical knowledge of DNA. Students gain a sense of ownership and are more enthusiastic when they use their own DNA. A cost effective, simple protocol for DNA extraction and visualization was devised. Buccal mucosal epithelia provide a…
Heat Transfer Modeling of Jet Vane Thrust Vector Control (TVC) Systems.
1987-12-01
Cost and complexity, to include materials, labor , design and fabrication. b. Effectiveness and ability to perform two and three axis control. c...8217 ESTR ’) CALL ESTRGR C C.... SCRS contains the simple-chemical-reaction-model of C combustion, the theoretical basis of which is found in the C book
Bakeout Chamber Within Vacuum Chamber
NASA Technical Reports Server (NTRS)
Taylor, Daniel M.; Soules, David M.; Barengoltz, Jack B.
1995-01-01
Vacuum-bakeout apparatus for decontaminating and measuring outgassing from pieces of equipment constructed by mounting bakeout chamber within conventional vacuum chamber. Upgrade cost effective: fabrication and installation of bakeout chamber simple, installation performed quickly and without major changes in older vacuum chamber, and provides quantitative data on outgassing from pieces of equipment placed in bakeout chamber.
Liu, Jing-fu; Liu, Rui; Yin, Yong-guang; Jiang, Gui-bin
2009-03-28
Capable of preserving the sizes and shapes of nanomaterials during the phase transferring, Triton X-114 based cloud point extraction provides a general, simple, and cost-effective route for reversible concentration/separation or dispersion of various nanomaterials in the aqueous phase.
Distillation and isolation of commodity chemicals from Bio-oil made by tail-gas reactive prolysis
USDA-ARS?s Scientific Manuscript database
Owing to instabilities, very little has been accomplished with regards to simple cost-effective separations of fast-pyrolysis bio-oil. However, recent developments in the use of tail-gas reactive pyrolysis (TGRP) (Mullen and Boateng 2013) provide higher quality bio-oils that are thermally stable. We...
Changing Fonts in Education: How the Benefits Vary with Ability and Dyslexia
ERIC Educational Resources Information Center
French, M. M. J.; Blood, Arabella; Bright, N. D.; Futak, Dez; Grohmann, M. J.; Hasthorpe, Alex; Heritage, John; Poland, Remy L.; Reece, Simon; Tabor, Jennifer
2013-01-01
Previous research has shown that presenting educational materials in slightly harder to read fonts than is typical engenders deeper processing. This leads to better retention and subsequent recall of information. Before this extremely simple-to-implement and cost-effective adaptation can be made routinely to educational materials, it needs to be…
Contemporary Approaches for Assessing Outcomes on Training, Education, and HRD Programs
ERIC Educational Resources Information Center
Brauchle, Paul E.; Schmidt, Klaus
2004-01-01
When educators, trainers, and human resource development (HRD) practitioners are asked to produce evidence that supports the productivity of the training enterprise, they are often frustrated by the lack of simple and effective methods for assessment. While administrators in an organization are likely to know exactly how much training costs, they…
Biochemist-Tree: Using Modular Origami to Understand the Integration of Intermediary Metabolism
ERIC Educational Resources Information Center
Sharp, Duncan
2013-01-01
Intermediary metabolism can be a complex area to study due to the inherent modularity of the catabolic biochemical processes. This article outlines a novel, cost-effective, and universally applicable teaching activity to enhance students understanding of the inter-relationship between the key processes of intermediary metabolism. A simple origami…
Rodríguez-Limas, William A; Pastor, Ana Ruth; Esquivel-Soto, Ernesto; Esquivel-Guadarrama, Fernando; Ramírez, Octavio T; Palomares, Laura A
2014-05-19
Rotavirus is the most common cause of severe diarrhea in many animal species of economic interest. A simple, safe and cost-effective vaccine is required for the control and prevention of rotavirus in animals. In this study, we evaluated the use of Saccharomyces cerevisiae extracts containing rotavirus-like particles (RLP) as a vaccine candidate in an adult mice model. Two doses of 1mg of yeast extract containing rotavirus proteins (between 0.3 and 3 μg) resulted in an immunological response capable of reducing the replication of rotavirus after infection. Viral shedding in all mice groups diminished in comparison with the control group when challenged with 100 50% diarrhea doses (DD50) of murine rotavirus strain EDIM. Interestingly, when immunizing intranasally protection against rotavirus infection was observed even when no increase in rotavirus-specific antibody titers was evident, suggesting that cellular responses were responsible of protection. Our results indicate that raw yeast extracts containing rotavirus proteins and RLP are a simple, cost-effective alternative for veterinary vaccines against rotavirus. Copyright © 2014 Elsevier Ltd. All rights reserved.
Modelling cost-effectiveness of different vasectomy methods in India, Kenya, and Mexico.
Seamans, Yancy; Harner-Jay, Claudia M
2007-07-13
Vasectomy is generally considered a safe and effective method of permanent contraception. The historical effectiveness of vasectomy has been questioned by recent research results indicating that the most commonly used method of vasectomy--simple ligation and excision (L and E)--appears to have a relatively high failure rate, with reported pregnancy rates as high as 4%. Updated methods such as fascial interposition (FI) and thermal cautery can lower the rate of failure but may require additional financial investments and may not be appropriate for low-resource clinics. In order to better compare the cost-effectiveness of these different vasectomy methods, we modelled the costs of different vasectomy methods using cost data collected in India, Kenya, and Mexico and effectiveness data from the latest published research. The costs associated with providing vasectomies were determined in each country through interviews with clinic staff. Costs collected were economic, direct, programme costs of fixed vasectomy services but did not include large capital expenses or general recurrent costs for the health care facility. Estimates of the time required to provide service were gained through interviews and training costs were based on the total costs of vasectomy training programmes in each country. Effectiveness data were obtained from recent published studies and comparative cost-effectiveness was determined using cost per couple years of protection (CYP). In each country, the labour to provide the vasectomy and follow-up services accounts for the greatest portion of the overall cost. Because each country almost exclusively used one vasectomy method at all of the clinics included in the study, we modelled costs based on the additional material, labour, and training costs required in each country. Using a model of a robust vasectomy program, more effective methods such as FI and thermal cautery reduce the cost per CYP of a vasectomy by $0.08-$0.55. Based on the results presented, more effective methods of vasectomy--including FI, thermal cautery, and thermal cautery combined with FI--are more cost-effective than L and E alone. Analysis shows that for a programme in which a minimum of 20 clients undergo vasectomies per month, the cost per CYP is reduced in all three countries by updated vasectomy methods.
Modelling cost-effectiveness of different vasectomy methods in India, Kenya, and Mexico
Seamans, Yancy; Harner-Jay, Claudia M
2007-01-01
Background Vasectomy is generally considered a safe and effective method of permanent contraception. The historical effectiveness of vasectomy has been questioned by recent research results indicating that the most commonly used method of vasectomy – simple ligation and excision (L and E) – appears to have a relatively high failure rate, with reported pregnancy rates as high as 4%. Updated methods such as fascial interposition (FI) and thermal cautery can lower the rate of failure but may require additional financial investments and may not be appropriate for low-resource clinics. In order to better compare the cost-effectiveness of these different vasectomy methods, we modelled the costs of different vasectomy methods using cost data collected in India, Kenya, and Mexico and effectiveness data from the latest published research. Methods The costs associated with providing vasectomies were determined in each country through interviews with clinic staff. Costs collected were economic, direct, programme costs of fixed vasectomy services but did not include large capital expenses or general recurrent costs for the health care facility. Estimates of the time required to provide service were gained through interviews and training costs were based on the total costs of vasectomy training programmes in each country. Effectiveness data were obtained from recent published studies and comparative cost-effectiveness was determined using cost per couple years of protection (CYP). Results In each country, the labour to provide the vasectomy and follow-up services accounts for the greatest portion of the overall cost. Because each country almost exclusively used one vasectomy method at all of the clinics included in the study, we modelled costs based on the additional material, labour, and training costs required in each country. Using a model of a robust vasectomy program, more effective methods such as FI and thermal cautery reduce the cost per CYP of a vasectomy by $0.08 – $0.55. Conclusion Based on the results presented, more effective methods of vasectomy – including FI, thermal cautery, and thermal cautery combined with FI – are more cost-effective than L and E alone. Analysis shows that for a programme in which a minimum of 20 clients undergo vasectomies per month, the cost per CYP is reduced in all three countries by updated vasectomy methods. PMID:17629921
Cost-effectiveness analysis of interventions for migraine in four low- and middle-income countries.
Linde, Mattias; Steiner, Timothy J; Chisholm, Dan
2015-02-18
Evidence of the cost and effects of interventions for reducing the global burden of migraine remains scarce. Our objective was to estimate the population-level cost-effectiveness of evidence-based migraine interventions and their contributions towards reducing current burden in low- and middle-income countries. Using a standard WHO approach to cost-effectiveness analysis (CHOICE), we modelled core set intervention strategies for migraine, taking account of coverage and efficacy as well as non-adherence. The setting was primary health care including pharmacies. We modelled 26 intervention strategies implemented during 10 years. These included first-line acute and prophylactic drugs, and the expected consequences of adding consumer-education and provider-training. Total population-level costs and effectiveness (healthy life years [HLY] gained) were combined to form average and incremental cost-effectiveness ratios. We executed runs of the model for the general populations of China, India, Russia and Zambia. Of the strategies considered, acute treatment of attacks with acetylsalicylic acid (ASA) was by far the most cost-effective and generated a HLY for less than US$ 100. Adding educational actions increased annual costs by 1-2 US cents per capita of the population. Cost-effectiveness ratios then became slightly less favourable but still less than US$ 100 per HLY gained for ASA. An incremental cost of > US$ 10,000 would have to be paid per extra HLY by adding a triptan in a stepped-care treatment paradigm. For prophylaxis, amitriptyline was more cost-effective than propranolol or topiramate. Self-management with simple analgesics was by far the most cost-effective strategy for migraine treatment in low- and middle-income countries and represents a highly efficient use of health resources. Consumer education and provider training are expected to accelerate progress towards desired levels of coverage and adherence, cost relatively little to implement, and can therefore be considered also economically attractive. Evidence-based interventions for migraine should have as much a claim on scarce health resources as those for other chronic, non-communicable conditions that impose a significant burden on societies.
Simple fluorescence-based high throughput cell viability assay for filamentous fungi.
Chadha, S; Kale, S P
2015-09-01
Filamentous fungi are important model organisms to understand the eukaryotic process and have been frequently exploited in research and industry. These fungi are also causative agents of serious diseases in plants and humans. Disease management strategies include in vitro susceptibility testing of the fungal pathogens to environmental conditions and antifungal agents. Conventional methods used for antifungal susceptibilities are cumbersome, time-consuming and are not suitable for a large-scale analysis. Here, we report a rapid, high throughput microplate-based fluorescence method for investigating the toxicity of antifungal and stress (osmotic, salt and oxidative) agents on Magnaporthe oryzae and compared it with agar dilution method. This bioassay is optimized for the resazurin reduction to fluorescent resorufin by the fungal hyphae. Resazurin bioassay showed inhibitory rates and IC50 values comparable to the agar dilution method and to previously reported IC50 or MICs for M. oryzae and other fungi. The present method can screen range of test agents from different chemical classes with different modes of action for antifungal activities in a simple, sensitive, time and cost effective manner. A simple fluorescence-based high throughput method is developed to test the effects of stress and antifungal agents on viability of filamentous fungus Magnaporthe oryzae. This resazurin fluorescence assay can detect inhibitory effects comparable to those obtained using the growth inhibition assay with added advantages of simplicity, time and cost effectiveness. This high throughput viability assay has a great potential in large-scale screening of the chemical libraries of antifungal agents, for evaluating the effects of environmental conditions and hyphal kinetic studies in mutant and natural populations of filamentous fungi. © 2015 The Society for Applied Microbiology.
Operational experience in underwater photogrammetry
NASA Astrophysics Data System (ADS)
Leatherdale, John D.; John Turner, D.
Underwater photogrammetry has become established as a cost-effective technique for inspection and maintenance of platforms and pipelines for the offshore oil industry. A commercial service based in Scotland operates in the North Sea, USA, Brazil, West Africa and Australia. 70 mm cameras and flash units are built for the purpose and analytical plotters and computer graphics systems are used for photogrammetric measurement and analysis of damage, corrosion, weld failures and redesign of underwater structures. Users are seeking simple, low-cost systems for photogrammetric analysis which their engineers can use themselves.
NASA Astrophysics Data System (ADS)
Cha, Kyoung Je; Kim, Taewan; Jea Park, Sung; Kim, Dong Sung
2014-11-01
Polymer microneedle arrays (MNAs) have received much attention for their use in transdermal drug delivery and microneedle therapy systems due to the advantages they offer, such as low cost, good mechanical properties, and a versatile choice of materials. Here, we present a simple and cost-effective method for the fabrication of a biodegradable polymer MNA in which the aspect ratio of each microneedle is adjustable using commercially available acupuncture microneedles. In our process, a master template with acupuncture microneedles, whose shape will be the final MNA, was carefully prepared by fixing them onto a plastic substrate with selectively drilled holes which, in turn, determine the aspect ratios of the microneedles. A polylactic acid (PLA; a biodegradable polymer) MNA was fabricated by a micromolding process with a polydimethylsiloxane (PDMS) mold containing the cavity of the microneedles, which was obtained by the PDMS replica molding against the master template. The mechanical force and degradation behavior of the replicated PLA MNA were characterized with the help of a compression test and an accelerated degradation test, respectively. Finally, the transdermal drug delivery performance of the PLA MNA was successfully simulated by two different methods of penetration and staining, using the skin of a pig cadaver. These results indicated that the proposed method can be effectively used for the fabrication of polymer MNAs which can be used in various microneedle applications.
[Effectiveness, benefit and necessity: making an attempt at a scientific definition].
Köbberling, Johannes
2009-01-01
Effectiveness does not always mean benefit but there is no benefit without effectiveness. Benefit does not always involve necessity but there is no necessity without benefit. In spite of this simple relationship these three important terms of the social security regulations are not well-defined. The array of the terms "effectiveness", "benefit" and "necessity" exhibits a decreasing accuracy of definition, a diminishing popularity in the context of scientific discourse, a rising importance for cost compensation, an increase of context dependencies and growing judgement dependence.
Kiss, H; Pichler, Eva; Petricevic, L; Husslein, P
2006-08-01
The purpose of this investigation was to determine the cost-saving potential of a simple screen-and-treat program for vaginal infection, which has previously been shown to lead to a reduction of 50% in the rate of preterm births. To determine the potential cost savings, we compared the direct costs of preterm delivery of infants with a birth weight below 1900g with the costs of the screen-and-treat program. We used a cut-off birth weight of 1900g because, in our population, all infants with a birth weight below 1900g were transferred to the neonatal intensive care unit. The direct costs associated with preterm delivery were defined to include the costs of the initial hospitalization of both mother and infant and the costs of outpatient follow-up throughout the first 6 years of life of the former preterm infant. The costs of the screen-and-treat program were defined to include the costs of the screening examination and the resulting costs of antimicrobial treatment and follow-up. All calculations were based on health-economic data obtained in the metropolitan area of Vienna, Austria. The number of preterm infants with a birth weight below 1900g was 12 (0.5%) in the intervention group (N=2058) and 29 (1.3%) in the control group (N=2097). The direct costs per preterm birth were found to amount to EUR (euro) 60262. Overall, the expected total savings in direct costs achieved by the screen-and-treat program and the ensuing 50% reduction in the number preterm births with a birth weight below 1900g amounted to more than euro 11 million. The costs of screening and treatment were found to amount to merely 7% of the direct costs saved as a result of the screen-and-treat program. A simple preterm prevention program, consisting of screening and antimicrobial treatment and follow-up of women with asymptomatic vaginal infection, leads not only to a significant reduction in the rate of preterm births but also to substantial savings in the direct costs associated with prematurity.
Simple morphological control over functional diversity of SERS materials
NASA Astrophysics Data System (ADS)
Semenova, A. A.; Goodilin, E. A.
2018-03-01
Nowadays, surface-enhanced Raman spectroscopy (SERS) becomes a promising universal low-cost and real-time tool in biomedical applications, medical screening or forensic analysis allowing for detection of different molecules below nanomolar concentrations. Silver nanoparticles and nanostructures have proven to be a common choice for SERS measurements due to a tunable plasmon resonance, high stability and facile fabrication methods. However, a proper design of silver-based nanomaterials for highly sensitive SERS applications still remains a challenge. In this work, effective and simple preparation methods of various silver nanostructures are proposed and systematically developed using aqueous diamminesilver (I) hydroxide as a precursor.
Gerke, Oke; Poulsen, Mads H; Høilund-Carlsen, Poul Flemming
2015-01-01
Diagnostic studies of accuracy targeting sensitivity and specificity are commonly done in a paired design in which all modalities are applied in each patient, whereas cost-effectiveness and cost-utility analyses are usually assessed either directly alongside to or indirectly by means of stochastic modeling based on larger randomized controlled trials (RCTs). However the conduct of RCTs is hampered in an environment such as ours, in which technology is rapidly evolving. As such, there is a relatively limited number of RCTs. Therefore, we investigated as to which extent paired diagnostic studies of accuracy can be also used to shed light on economic implications when considering a new diagnostic test. We propose a simple decision tree model-based cost-utility analysis of a diagnostic test when compared to the current standard procedure and exemplify this approach with published data from lymph node staging of prostate cancer. Average procedure costs were taken from the Danish Diagnosis Related Groups Tariff in 2013 and life expectancy was estimated for an ideal 60 year old patient based on prostate cancer stage and prostatectomy or radiation and chemotherapy. Quality-adjusted life-years (QALYs) were deduced from the literature, and an incremental cost-effectiveness ratio (ICER) was used to compare lymph node dissection with respective histopathological examination (reference standard) and (18)F-fluoromethylcholine positron emission tomography/computed tomography (FCH-PET/CT). Lower bounds of sensitivity and specificity of FCH-PET/CT were established at which the replacement of the reference standard by FCH-PET/CT comes with a trade-off between worse effectiveness and lower costs. Compared to the reference standard in a diagnostic accuracy study, any imperfections in accuracy of a diagnostic test imply that replacing the reference standard generates a loss in effectiveness and utility. We conclude that diagnostic studies of accuracy can be put to a more extensive use, over and above a mere indication of sensitivity and specificity of an imaging test, and that health economic considerations should be undertaken when planning a prospective diagnostic accuracy study. These endeavors will prove especially fruitful when comparing several imaging techniques with one another, or the same imaging technique using different tracers, with an independent reference standard for the evaluation of results.
Two-part payments for the reimbursement of investments in health technologies.
Levaggi, Rosella; Moretto, Michele; Pertile, Paolo
2014-04-01
The paper studies the impact of alternative reimbursement systems on two provider decisions: whether to adopt a technology whose provision requires a sunk investment cost and how many patients to treat with it. Using a simple economic model we show that the optimal pricing policy involves a two-part payment: a price equal to the marginal cost of the patient whose benefit of treatment equals the cost of provision, and a separate payment for the partial reimbursement of capital costs. Departures from this scheme, which are frequent in DRG tariff systems designed around the world, lead to a trade-off between the objective of making effective technologies available to patients and the need to ensure appropriateness in use. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
A simple and low-cost permanent magnet system for NMR.
Chonlathep, K; Sakamoto, T; Sugahara, K; Kondo, Y
2017-02-01
We have developed a simple, easy to build, and low-cost magnet system for NMR, of which homogeneity is about 4×10 -4 at 57mT, with a pair of two commercially available ferrite magnets. This homogeneity corresponds to about 90Hz spectral resolution at 2.45MHz of the hydrogen Larmor frequency. The material cost of this NMR magnet system is little more than $100. The components can be printed by a 3D printer. Copyright © 2016 Elsevier Inc. All rights reserved.
Simple Automatic File Exchange (SAFE) to Support Low-Cost Spacecraft Operation via the Internet
NASA Technical Reports Server (NTRS)
Baker, Paul; Repaci, Max; Sames, David
1998-01-01
Various issues associated with Simple Automatic File Exchange (SAFE) are presented in viewgraph form. Specific topics include: 1) Packet telemetry, Internet IP networks and cost reduction; 2) Basic functions and technical features of SAFE; 3) Project goals, including low-cost satellite transmission to data centers to be distributed via an Internet; 4) Operations with a replicated file protocol; 5) File exchange operation; 6) Ground stations as gateways; 7) Lessons learned from demonstrations and tests with SAFE; and 8) Feedback and future initiatives.
Alkoshi, Salem; Maimaiti, Namaitijiang; Dahlui, Maznah
2014-01-01
Background Rotavirus infection is a major cause of childhood diarrhea in Libya. The objective of this study is to evaluate the cost-effectiveness of rotavirus vaccination in that country. Methods We used a published decision tree model that has been adapted to the Libyan situation to analyze a birth cohort of 160,000 children. The evaluation of diarrhea events in three public hospitals helped to estimate the rotavirus burden. The economic analysis was done from two perspectives: health care provider and societal. Univariate sensitivity analyses were conducted to assess uncertainty in some values of the variables selected. Results The three hospitals received 545 diarrhea patients aged≤5 with 311 (57%) rotavirus positive test results during a 9-month period. The societal cost for treatment of a case of rotavirus diarrhea was estimated at US$ 661/event. The incremental cost-effectiveness ratio with a vaccine price of US$ 27 per course was US$ 8,972 per quality-adjusted life year gained from the health care perspective. From a societal perspective, the analysis shows cost savings of around US$ 16 per child. Conclusion The model shows that rotavirus vaccination could be economically a very attractive intervention in Libya. PMID:25499622
Zheng, Hao-Bo; Ding, Jun; Zheng, Shu-Jian; Zhu, Gang-Tian; Yuan, Bi-Feng; Feng, Yu-Qi
2016-01-01
In this study, we proposed a method to fabricate magnetic carbon nitride (CN) nanosheets by simple physical blending. Low-cost CN nanosheets prepared by urea possessed a highly π-conjugated structure; therefore the obtained composites were employed as magnetic solid-phase extraction (MSPE) sorbent for extraction of polycyclic aromatic hydrocarbons (PAHs) in edible oil samples. Moreover, sample pre-treatment time could be carried out within 10 min. Thus, a simple and cheap method for the analysis of PAHs in edible oil samples was established by coupling magnetic CN nanosheets-based MSPE with gas chromatography-mass spectrometry (GC/MS) analysis. Limits of quantitation (LOQs) for eight PAHs ranged from 0.4 to 0.9 ng/g. The intra- and inter-day relative standard deviations (RSDs) were less than 15.0%. The recoveries of PAHs for spiked soybean oil samples ranged from 91.0% to 124.1%, with RSDs of less than 10.2%. Taken together, the proposed method offers a simple and cost-effective option for the convenient analysis of PAHs in oil samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Self-powered Imbibing Microfluidic Pump by Liquid Encapsulation: SIMPLE.
Kokalj, Tadej; Park, Younggeun; Vencelj, Matjaž; Jenko, Monika; Lee, Luke P
2014-11-21
Reliable, autonomous, internally self-powered microfluidic pumps are in critical demand for rapid point-of-care (POC) devices, integrated molecular-diagnostic platforms, and drug delivery systems. Here we report on a Self-powered Imbibing Microfluidic Pump by Liquid Encapsulation (SIMPLE), which is disposable, autonomous, easy to use and fabricate, robust, and cost efficient, as a solution for self-powered microfluidic POC devices. The imbibition pump introduces the working liquid which is sucked into a porous material (paper) upon activation. The suction of the working liquid creates a reduced pressure in the analytical channel and induces the sequential sample flow into the microfluidic circuits. It requires no external power or control and can be simply activated by a fingertip press. The flow rate can be programmed by defining the shape of utilized porous material: by using three different paper shapes with circular section angles 20°, 40° and 60°, three different volume flow rates of 0.07 μL s(-1), 0.12 μL s(-1) and 0.17 μL s(-1) are demonstrated at 200 μm × 600 μm channel cross-section. We established the SIMPLE pumping of 17 μL of sample; however, the sample volume can be increased to several hundreds of μL. To demonstrate the design, fabrication, and characterization of SIMPLE, we used a simple, robust and cheap foil-laminating fabrication technique. The SIMPLE can be integrated into hydrophilic or hydrophobic materials-based microfluidic POC devices. Since it is also applicable to large-scale manufacturing processes, we anticipate that a new chapter of a cost effective, disposable, autonomous POC diagnostic chip is addressed with this technical innovation.
López-Ferrer, Daniel; Hixson, Kim K.; Smallwood, Heather; Squier, Thomas C.; Petritis, Konstantinos; Smith, Richard D.
2009-01-01
A new method that uses immobilized trypsin concomitant with ultrasonic irradiation results in ultra-rapid digestion and thorough 18O labeling for quantitative protein comparisons. The reproducible and highly efficient method provided effective digestions in <1 min with a minimized amount of enzyme required compared to traditional methods. This method was demonstrated for digestion of both simple and complex protein mixtures, including bovine serum albumin, a global proteome extract from the bacteria Shewanella oneidensis, and mouse plasma, as well as 18O labeling of such complex protein mixtures, which validated the application of this method for differential proteomic measurements. This approach is simple, reproducible, cost effective, rapid, and thus well-suited for automation. PMID:19555078
Study of CdTe/CdS solar cell at low power density for low-illumination applications
NASA Astrophysics Data System (ADS)
Devi, Nisha; Aziz, Anver; Datta, Shouvik
2016-05-01
In this paper, we numerically investigate CdTe/CdS PV cell properties using a simulation program Solar Cell Capacitance Simulator in 1D (SCAPS-1D). A simple structure of CdTe PV cell has been optimized to study the effect of temperature, absorber thickness and work function at very low incident power. Objective of this research paper is to build an efficient and cost effective solar cell for portable electronic devices such as portable computers and cell phones that work at low incident power because most of such devices work at diffused and reflected sunlight. In this report, we simulated a simple CdTe PV cell at very low incident power, which gives good efficiency.
Implementing Computer Based Laboratories
NASA Astrophysics Data System (ADS)
Peterson, David
2001-11-01
Physics students at Francis Marion University will complete several required laboratory exercises utilizing computer-based Vernier probes. The simple pendulum, the acceleration due to gravity, simple harmonic motion, radioactive half lives, and radiation inverse square law experiments will be incorporated into calculus-based and algebra-based physics courses. Assessment of student learning and faculty satisfaction will be carried out by surveys and test results. Cost effectiveness and time effectiveness assessments will be presented. Majors in Computational Physics, Health Physics, Engineering, Chemistry, Mathematics and Biology take these courses, and assessments will be categorized by major. To enhance the computer skills of students enrolled in the courses, MAPLE will be used for further analysis of the data acquired during the experiments. Assessment of these enhancement exercises will also be presented.
Sex workers can be screened too often: a cost-effectiveness analysis in Victoria, Australia.
Wilson, David P; Heymer, Kelly-Jean; Anderson, Jonathan; O'Connor, Jody; Harcourt, Christine; Donovan, Basil
2010-04-01
Commercial sex is licensed in Victoria, Australia such that sex workers are required to have regular tests for sexually transmitted infections (STIs). However, the incidence and prevalence of STIs in sex workers are very low, especially since there is almost universal condom use at work. We aimed to conduct a cost-effectiveness analysis of the financial cost of the testing policy versus the health benefits of averting the transmission of HIV, syphilis, chlamydia and gonorrhoea to clients. We developed a simple mathematical transmission model, informed by conservative parameter estimates from all available data, linked to a cost-effectiveness analysis. We estimated that under current testing rates, it costs over $A90,000 in screening costs for every chlamydia infection averted (and $A600,000 in screening costs for each quality-adjusted life year (QALY) saved) and over $A4,000,000 for every HIV infection averted ($A10,000,000 in screening costs for each QALY saved). At an assumed willingness to pay of $A50,000 per QALY gained, HIV testing should not be conducted less than approximately every 40 weeks and chlamydia testing approximately once per year; in comparison, current requirements are testing every 12 weeks for HIV and every 4 weeks for chlamydia. Mandatory screening of female sex workers at current testing frequencies is not cost-effective for the prevention of disease in their male clients. The current testing rate required of sex workers in Victoria is excessive. Screening intervals for sex workers should be based on local STI epidemiology and not locked by legislation.
Portable and cost-effective pixel super-resolution on-chip microscope for telemedicine applications.
Bishara, Waheb; Sikora, Uzair; Mudanyali, Onur; Su, Ting-Wei; Yaglidere, Oguzhan; Luckhart, Shirley; Ozcan, Aydogan
2011-01-01
We report a field-portable lensless on-chip microscope with a lateral resolution of <1 μm and a large field-of-view of ~24 mm(2). This microscope is based on digital in-line holography and a pixel super-resolution algorithm to process multiple lensfree holograms and obtain a single high-resolution hologram. In its compact and cost-effective design, we utilize 23 light emitting diodes butt-coupled to 23 multi-mode optical fibers, and a simple optical filter, with no moving parts. Weighing only ~95 grams, we demonstrate the performance of this field-portable microscope by imaging various objects including human malaria parasites in thin blood smears.
Yoo, Seunghwan; Song, Ho Young; Lee, Junghoon; Jang, Cheol-Yong; Jeong, Hakgeun
2012-11-20
In this article, we introduce a simple fabrication method for SiO(2)-based thin diffractive optical elements (DOEs) that uses the conventional processes widely used in the semiconductor industry. Photolithography and an inductively coupled plasma etching technique are easy and cost-effective methods for fabricating subnanometer-scale and thin DOEs with a refractive index of 1.45, based on SiO(2). After fabricating DOEs, we confirmed the shape of the output light emitted from the laser diode light source and applied to a light-emitting diode (LED) module. The results represent a new approach to mass-produce DOEs and realize a high-brightness LED module.
A Versatile PDMS/Paper Hybrid Microfluidic Platform for Sensitive Infectious Disease Diagnosis
2015-01-01
Bacterial meningitis is a serious health concern worldwide. Given that meningitis can be fatal and many meningitis cases occurred in high-poverty areas, a simple, low-cost, highly sensitive method is in great need for immediate and early diagnosis of meningitis. Herein, we report a versatile and cost-effective polydimethylsiloxane (PDMS)/paper hybrid microfluidic device integrated with loop-mediated isothermal amplification (LAMP) for the rapid, sensitive, and instrument-free detection of the main meningitis-causing bacteria, Neisseria meningitidis (N. meningitidis). The introduction of paper into the microfluidic device for LAMP reactions enables stable test results over a much longer period of time than a paper-free microfluidic system. This hybrid system also offers versatile functions, by providing not only on-site qualitative diagnostic analysis (i.e., a yes or no answer), but also confirmatory testing and quantitative analysis in laboratory settings. The limit of detection of N. meningitidis is about 3 copies per LAMP zone within 45 min, close to single-bacterium detection sensitivity. In addition, we have achieved simple pathogenic microorganism detection without a laborious sample preparation process and without the use of centrifuges. This low-cost hybrid microfluidic system provides a simple and highly sensitive approach for fast instrument-free diagnosis of N. meningitidis in resource-limited settings. This versatile PDMS/paper microfluidic platform has great potential for the point of care (POC) diagnosis of a wide range of infectious diseases, especially for developing nations. PMID:25019330
Control and Effort Costs Influence the Motivational Consequences of Choice
Sullivan-Toole, Holly; Richey, John A.; Tricomi, Elizabeth
2017-01-01
The act of making a choice, apart from any outcomes the choice may yield, has, paradoxically, been linked to both the enhancement and the detriment of intrinsic motivation. Research has implicated two factors in potentially mediating these contradictory effects: the personal control conferred by a choice and the costs associated with a choice. Across four experiments, utilizing a physical effort task disguised as a simple video game, we systematically varied costs across two levels of physical effort requirements (Low-Requirement, High-Requirement) and control over effort costs across three levels of choice (Free-Choice, Restricted-Choice, and No-Choice) to disambiguate how these factors affect the motivational consequences of choosing within an effortful task. Together, our results indicated that, in the face of effort requirements, illusory control alone may not sufficiently enhance perceptions of personal control to boost intrinsic motivation; rather, the experience of actual control may be necessary to overcome effort costs and elevate performance. Additionally, we demonstrated that conditions of illusory control, while otherwise unmotivating, can through association with the experience of free-choice, be transformed to have a positive effect on motivation. PMID:28515705
A simple cost-effective design for construction of a laparoscopic trainer.
Ricchiuti, Daniel; Ralat, Dane Arends; Evancho-Chapman, Michelle; Wyneski, Holly; Cerone, Jeffrey; Wegryn, John D
2005-10-01
Laparoscopic trainers have been shown to be effective tools for transitioning residents in surgical fields into live laparoscopic techniques. There have been few reports of homemade trainers, but each of these reports provides only scant detail about their construction, making production a novel task to those interested in employing this equipment. Virtual-reality trainers are gaining popularity and are exceptional modalities in the re-creation of laparoscopic surgery. In their present state, however, such trainers are very costly, making them unattainable by most urology residency programs. Numerous commercial non-virtual trainers are also available; however, these trainers are often cost-prohibitive or overly simplistic. We describe a detailed design template for creation of a laparoscopic trainer based on modifications of previous designs. This trainer can be made easily at a cost of approximately US$275.00 and may be used in conjunction with existing laparoscopic equipment. The methods described herein can be followed by any local machinist to create this trainer. The relatively low total cost, ready material availability, and ease of construction make this trainer an appropriate option for the training of residents in laparoscopic procedures.
ERIC Educational Resources Information Center
Dean, Michelle L.; Miller, Tyson A.; Bruckner, Christian
2011-01-01
A simple and cost-effective laboratory experiment is described that extracts protoporphyrin IX from brown eggshells. The porphyrin is characterized by UV-vis and fluorescence spectroscopy. A chemiluminescence reaction (peroxyoxalate ester fragmentation) is performed that emits light in the UV region. When the porphyrin extract is added as a fluor…
The effect of exchange rates on southern pine exports
H.W. Wisdom; James E. Granskog
2003-01-01
Changes in exchange rates affect southern pine exports by changing the cost of southern wood in foreign markets. A strong dollar discourages exports; a weak dollar encourages exports. A simple economic export market model is developed to determine whether changes in the exchange rates in foreign markets of southern pine products have, in fact, let to significant...
ERIC Educational Resources Information Center
Meeks, Glenn E.; Fisher, Ricki; Loveless, Warren
Personnel involved in planning or developing schools lack the costing tools that will enable them to determine educational technology costs. This report presents an overview of the technology costing process and the general costs used in estimating educational technology systems on a macro-budget basis, along with simple cost estimates for…
A case-mix classification system for explaining healthcare costs using administrative data in Italy.
Corti, Maria Chiara; Avossa, Francesco; Schievano, Elena; Gallina, Pietro; Ferroni, Eliana; Alba, Natalia; Dotto, Matilde; Basso, Cristina; Netti, Silvia Tiozzo; Fedeli, Ugo; Mantoan, Domenico
2018-03-04
The Italian National Health Service (NHS) provides universal coverage to all citizens, granting primary and hospital care with a copayment system for outpatient and drug services. Financing of Local Health Trusts (LHTs) is based on a capitation system adjusted only for age, gender and area of residence. We applied a risk-adjustment system (Johns Hopkins Adjusted Clinical Groups System, ACG® System) in order to explain health care costs using routinely collected administrative data in the Veneto Region (North-eastern Italy). All residents in the Veneto Region were included in the study. The ACG system was applied to classify the regional population based on the following information sources for the year 2015: Hospital Discharges, Emergency Room visits, Chronic disease registry for copayment exemptions, ambulatory visits, medications, the Home care database, and drug prescriptions. Simple linear regressions were used to contrast an age-gender model to models incorporating more comprehensive risk measures aimed at predicting health care costs. A simple age-gender model explained only 8% of the variance of 2015 total costs. Adding diagnoses-related variables provided a 23% increase, while pharmacy based variables provided an additional 17% increase in explained variance. The adjusted R-squared of the comprehensive model was 6 times that of the simple age-gender model. ACG System provides substantial improvement in predicting health care costs when compared to simple age-gender adjustments. Aging itself is not the main determinant of the increase of health care costs, which is better explained by the accumulation of chronic conditions and the resulting multimorbidity. Copyright © 2018. Published by Elsevier B.V.
Information Sharing Among Military Headquarters: The Effects of Decisionmaking
2004-01-01
adopted Murray Gell-Mann’s more neutral term plec - ticity to describe the effects of the network infrastructure on military operations. This...benefits of network plec - ticity for a cluster within the network, associated with the mission at hand. The term ‘costs’ suggests a simple cost-benefit...network is logically connected to support a given mission. Plec - ticity for a cluster is then associated with the flow of information associated with
1982-07-01
palladium acetate and the appropriate phosphine . This procedure is known to be effective for bromoarenes. In the early screen- ing runs, 4...Delaware), he indicated that he also had screened many phosphines , and the likelihood of success was very small. Dr. Heck reported that the palladium...any simple modification of the palla- dium phosphine catalyst system will effect the desired reaction. 5 III. PREPARATION OF OLIGOMERIC BENZILS AND
Hepatic Resection for Colorectal Liver Metastases: A Cost-Effectiveness Analysis
Beard, Stephen M.; Holmes, Michael; Price, Charles; Majeed, Ali W.
2000-01-01
Objective To analyze the cost-effectiveness of resection for liver metastases compared with standard nonsurgical cytotoxic treatment. Summary Background Data The efficacy of hepatic resection for metastases from colorectal cancer has been debated, despite reported 5-year survival rates of 20% to 40%. Resection is confined to specialized centers and is not widely available, perhaps because of lack of appropriate expertise, resources, or awareness of its efficacy. The cost-effectiveness of resection is important from the perspective of managed care in the United States and for the commissioning of health services in the United Kingdom. Methods A simple decision-based model was developed to evaluate the marginal costs and health benefits of hepatic resection. Estimates of resectability for liver metastases were taken from UK-reported case series data. The results of 100 hepatic resections conducted in Sheffield from 1997 to 1999 were used for the cost calculation of liver resection. Survival data from published series of resections were compiled to estimate the incremental cost per life-year gained (LYG) because of the short period of follow-up in the Sheffield series. Results Hepatic resection for colorectal liver metastases provides an estimated marginal benefit of 1.6 life-years (undiscounted) at a marginal cost of £6,742. If 17% of patients have only palliative resections, the overall cost per LYG is approximately £5,236 (£5,985 with discounted benefits). If potential benefits are extended to include 20-year survival rates, these figures fall to approximately £1,821 (£2,793 with discounted benefits). Further univariate sensitivity analysis of key model parameters showed the cost per LYG to be consistently less than £15,000. Conclusion In this model, hepatic resection appears highly cost-effective compared with nonsurgical treatments for colorectal-related liver metastases. PMID:11088071
Quality and Growth Implications of Incremental Costing Models for Distance Education Units
ERIC Educational Resources Information Center
Crawford, C. B.; Gould, Lawrence V.; King, Dennis; Parker, Carl
2010-01-01
The purpose of this article is to explore quality and growth implications emergent from various incremental costing models applied to distance education units. Prior research relative to costing models and three competing costing models useful in the current distance education environment are discussed. Specifically, the simple costing model, unit…
Developing a cardiopulmonary exercise testing laboratory.
Diamond, Edward
2007-12-01
Cardiopulmonary exercise testing is a noninvasive and cost-effective technique that adds significant value to the assessment and management of a variety of symptoms and diseases. The penetration of this testing in medical practice may be limited by perceived operational and financial barriers. This article reviews coding and supervision requirements related to both simple and complex pulmonary stress testing. A program evaluation and review technique diagram is used to describe the work flow process. Data from our laboratory are used to generate an income statement that separates fixed and variable costs and calculates the contribution margin. A cost-volume-profit (break-even) analysis is then performed. Using data from our laboratory including fixed and variable costs, payer mix, reimbursements by payer, and the assumption that the studies are divided evenly between simple and complex pulmonary stress tests, the break-even number is calculated to be 300 tests per year. A calculator with embedded formulas has been designed by the author and is available on request. Developing a cardiopulmonary exercise laboratory is challenging but achievable and potentially profitable. It should be considered by a practice that seeks to distinguish itself as a quality leader. Providing this clinically valuable service may yield indirect benefits such as increased patient volume and increased utilization of other services provided by the practice. The decision for a medical practice to commit resources to managerial accounting support requires a cost-benefit analysis, but may be a worthwhile investment in our challenging economic environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brink, J.
Crude oil (c. 10,700 BOPD) was produced through temporary topside facilities in the Rolf Field offshore Denmark from January 7th to September 17th, 1986. These simple, unmanned and remote controlled facilities were a low cost solution to a problem caused by delays of the permanent topside facilities. Project execution time was two months from start of conceptual design until start-up of oil production. Installation works were performed from a jack-up drilling rig - in part simultaneously with drilling operations. Materials and equipment installed were obtained with very short delivery times. The facilties which were certified by a Certification Society andmore » approved by the Danish Authoritites included all necessary safety features. Total costs for the facilities amounted to c. 1 million US$ (excl. rig time for installation). Due to simplicity high reliability of the production system was obtained. Availability of the facilities for the entire period from start-up was 99.6 percent. The facilities were manned 3.2 percent of the total operating time mainly due to wireline work for reservoir monitoring. It is considered that the experience with the concept applied for the early production from the Rolf Field could form the basis for more simple and cost effective topside facilities for minor offshore fields.« less
Incentives for solar energy in industry
NASA Astrophysics Data System (ADS)
Bergeron, K. D.
1981-05-01
Several issues are analyzed on the effects that government subsidies and other incentives have on the use of solar energy in industry, as well as on other capital-intensive alternative energy supplies. Discounted cash flow analysis is used to compare tax deductions for fuel expenses with tax credits for capital investments for energy. The result is a simple expression for tax equity. The effects that market penetration of solar energy has on conventional energy prices are analyzed with a free market model. It is shown that net costs of a subsidy program to the society can be significantly reduced by price. Several government loan guarantee concepts are evaluated as incentives that may not require direct outlays of government funds; their relative effectiveness in achieving loan leverage through project financing, and their cost and practicality, are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Stimulated by public demand and state and federal legislation, industry has begun to develop bio- and photo- degradable plastics. so far, however, none of these degradable plastics meets all of the criteria for success - adequate physical and mechanical properties for the desired use, cost-effectiveness, and 100% degradability. Polylactic acid (PLA) plastic is one degradable plastic that shows promise. It has the desired properties and is 100% degradable. However, PLA plastic made by conventional techniques is not cost effective. Made from lactic acid, which is typically made form petroleum using a very costly synthesis process. Lactic acid can also bemore » made from carbohydrates (starches), found in food processing wastes such as potato wastes, cheese whey, and sorghum. Conversion of starch to simple sugars, and fermentation of these sugars can produce lactic acid.« less
Aeration control of thermophilic aerobic digestion using fluorescence monitoring.
Kim, Young-Kee; Oh, Byung-Keun
2009-01-01
The thermophilic aerobic digestion (TAD) process is recognized as an effective method for rapid waste activated sludge (WAS) degradation and the deactivation of pathogenic microorganisms. Yet, high energy costs due to heating and aeration have limited the commercialization of economical TAD processes. Previous research on autothermal thermophilic aerobic digestion (ATAD) has already reduced the heating cost. However, only a few studies have focused on reducing the aeration cost. Therefore, this study applied a two-step aeration control strategy to a fill-and-draw mode semicontinuous TAD process. The NADH-dependent fluorescence was monitored throughout the TAD experiment, and the aeration rate shifted according to the fluorescence intensity. As a result, the simple two-step aeration control operation achieved a 20.3% reduction in the total aeration, while maintaining an effective and stable operation. It is also expected that more savings can be achieved with a further reduction of the lower aeration rate or multisegmentation of the aeration rate.
Science and society test VI: Energy economics
NASA Astrophysics Data System (ADS)
Hafemeister, David W.
1982-01-01
Simple numerical estimates are developed in order to quantify a variety of energy economics issues. The Verhulst equation, which considers the effect of finite resources on petroleum production, is modified to take into account supply and demand economics. Numerical and analytical solutions to these differential equations are presented in terms of supply and demand elasticity functions, various finite resources, and the rate of increase in fuel costs. The indirect cost per barrel of imported oil from OPEC is shown to be about the same as the direct cost. These effects, as well as those of discounted benefits and deregulation, are used in a calculation of payback periods for various energy conserving devices. A phenomenological model for market penetration is developed along with the factors for future energy growth rates. A brief analysis of the economic returns of the ''house doctor'' program to reprofit houses for energy conservation is presented.
Gratitude and prosocial behavior: helping when it costs you.
Bartlett, Monica Y; DeSteno, David
2006-04-01
The ability of the emotion gratitude to shape costly prosocial behavior was examined in three studies employing interpersonal emotion inductions and requests for assistance. Study 1 demonstrated that gratitude increases efforts to assist a benefactor even when such efforts are costly (i.e., hedonically negative), and that this increase differs from the effects of a general positive affective state. Additionally, mediational analyses revealed that gratitude, as opposed to simple awareness of reciprocity norms, drove helping behavior. Furthering the theory that gratitude mediates prosocial behavior, Study 2 replicated the findings of Study 1 and demonstrated gratitude's ability to function as an incidental emotion by showing it can increase assistance provided to strangers. Study 3 revealed that this incidental effect dissipates if one is made aware of the true cause of the emotional state. Implications of these findings for the role of gratitude in building relationships are discussed.
DNA-Based Nanobiosensors as an Emerging Platform for Detection of Disease
Abu-Salah, Khalid M.; Zourob, Mohammed M.; Mouffouk, Fouzi; Alrokayan, Salman A.; Alaamery, Manal A.; Ansari, Anees A.
2015-01-01
Detection of disease at an early stage is one of the biggest challenges in medicine. Different disciplines of science are working together in this regard. The goal of nanodiagnostics is to provide more accurate tools for earlier diagnosis, to reduce cost and to simplify healthcare delivery of effective and personalized medicine, especially with regard to chronic diseases (e.g., diabetes and cardiovascular diseases) that have high healthcare costs. Up-to-date results suggest that DNA-based nanobiosensors could be used effectively to provide simple, fast, cost-effective, sensitive and specific detection of some genetic, cancer, and infectious diseases. In addition, they could potentially be used as a platform to detect immunodeficiency, and neurological and other diseases. This review examines different types of DNA-based nanobiosensors, the basic principles upon which they are based and their advantages and potential in diagnosis of acute and chronic diseases. We discuss recent trends and applications of new strategies for DNA-based nanobiosensors, and emphasize the challenges in translating basic research to the clinical laboratory. PMID:26102488
A design study for a simple-to-fly, constant attitude light aircraft
NASA Technical Reports Server (NTRS)
Smetana, F. O.; Humphreys, D. E.; Montoya, R. J.; Rickard, W. W.; Wilkinson, I. E.
1973-01-01
The activities during a four-year study by doctoral students to evolve in detail a design for a simple-to-fly, constant attitude light airplane are described. The study indicated that such aircraft could materially reduce the hazards to light airplane occupants which arise from the high pilot work load and poor visibility that occur during landing. Preliminary cost studies indicate that in volume production this system would increase the cost of the aircraft in roughly the same fashion that automatic transmission, power steering, power brakes, and cruise control increase the cost of a compact car.
Pushing the boundaries of viability: the economic impact of extreme preterm birth.
Petrou, Stavros; Henderson, Jane; Bracewell, Melanie; Hockley, Christine; Wolke, Dieter; Marlow, Neil
2006-02-01
Previous assessments of the economic impact of preterm birth focussed on short term health service costs across the broad spectrum of prematurity. To estimate the societal costs of extreme preterm birth during the sixth year after birth. Unit costs were applied to estimates of health, social and broader resource use made by 241 children born at 20 through 25 completed weeks of gestation in the United Kingdom and Republic of Ireland and a comparison group of 160 children born at full term. Societal costs per child during the sixth year after birth were estimated and subjected to a rigorous sensitivity analysis. The effects of gestational age at birth on annual societal costs were analysed, first in a simple linear regression and then in a multiple linear regression. Mean societal costs over the 12 month period were 9541 pounds sterling (standard deviation 11,678 pounds sterling) for the extreme preterm group and 3883 pounds sterling (1098 pounds sterling) for the term group, generating a mean cost difference of 5658 pounds sterling (bootstrap 95% confidence interval: 4203 pounds sterling, 7256 pounds sterling) that was statistically significant (P<0.001). After adjustment for clinical and sociodemographic covariates, sex-specific extreme preterm birth was a strong predictor of high societal costs. The results of this study should facilitate the effective planning of services and may be used to inform the development of future economic evaluations of interventions aimed at preventing extreme preterm birth or alleviating its effects.
NASA Astrophysics Data System (ADS)
Henley, E. M.; Pope, E. C. D.
2017-12-01
This commentary concerns recent work on solar wind forecasting by Owens and Riley (2017). The approach taken makes effective use of tools commonly used in terrestrial weather—notably, via use of a simple model—generation of an "ensemble" forecast, and application of a "cost-loss" analysis to the resulting probabilistic information, to explore the benefit of this forecast to users with different risk appetites. This commentary aims to highlight these useful techniques to the wider space weather audience and to briefly discuss the general context of application of terrestrial weather approaches to space weather.
Virtual Induction Loops Based on Cooperative Vehicular Communications
Gramaglia, Marco; Bernardos, Carlos J.; Calderon, Maria
2013-01-01
Induction loop detectors have become the most utilized sensors in traffic management systems. The gathered traffic data is used to improve traffic efficiency (i.e., warning users about congested areas or planning new infrastructures). Despite their usefulness, their deployment and maintenance costs are expensive. Vehicular networks are an emerging technology that can support novel strategies for ubiquitous and more cost-effective traffic data gathering. In this article, we propose and evaluate VIL (Virtual Induction Loop), a simple and lightweight traffic monitoring system based on cooperative vehicular communications. The proposed solution has been experimentally evaluated through simulation using real vehicular traces. PMID:23348033
NASA Astrophysics Data System (ADS)
Khan, Baseem; Agnihotri, Ganga; Mishra, Anuprita S.
2016-03-01
In the present work authors proposed a novel method for transmission loss and cost allocation to users (generators and loads). In the developed methodology transmission losses are allocated to users based on their usage of the transmission line. After usage allocation, particular loss allocation indices (PLAI) are evaluated for loads and generators. Also Cooperative game theory approach is applied for comparison of results. The proposed method is simple and easy to implement on the practical power system. Sample 6 bus and IEEE 14 bus system is used for showing the effectiveness of proposed method.
FOCIS: A forest classification and inventory system using LANDSAT and digital terrain data
NASA Technical Reports Server (NTRS)
Strahler, A. H.; Franklin, J.; Woodcook, C. E.; Logan, T. L.
1981-01-01
Accurate, cost-effective stratification of forest vegetation and timber inventory is the primary goal of a Forest Classification and Inventory System (FOCIS). Conventional timber stratification using photointerpretation can be time-consuming, costly, and inconsistent from analyst to analyst. FOCIS was designed to overcome these problems by using machine processing techniques to extract and process tonal, textural, and terrain information from registered LANDSAT multispectral and digital terrain data. Comparison of samples from timber strata identified by conventional procedures showed that both have about the same potential to reduce the variance of timber volume estimates over simple random sampling.
Design and fabrication of microstrip antenna arrays
NASA Technical Reports Server (NTRS)
1978-01-01
A microstrip array project was conducted to demonstrate the feasibility of designing and fabricating simple, low cost, low sidelobe phased arrays with circular disk microstrip radiating elements. Design data were presented for microstrip elements and arrays including the effects of the protective covers, the mutual interaction between elements, and stripline feed network design. Low cost multilayer laminate fabrication techniques were also investigated. Utilizing this design data two C-band low sidelobe arrays were fabricated and tested: an eight-element linear and a sixty-four element planar array. These arrays incorporated stripline Butler matrix feed networks to produce a low sidelobe broadside beam.
Anderson, Peter; Chisholm, Dan; Fuhr, Daniela C
2009-06-27
This paper reviews the evidence for the effectiveness and cost-effectiveness of policies and programmes to reduce the harm caused by alcohol, in the areas of education and information, the health sector, community action, driving while under the influence of alcohol (drink-driving), availability, marketing, pricing, harm reduction, and illegally and informally produced alcohol. Systematic reviews and meta-analyses show that policies regulating the environment in which alcohol is marketed (particularly its price and availability) are effective in reducing alcohol-related harm. Enforced legislative measures to reduce drink-driving and individually directed interventions to already at-risk drinkers are also effective. However, school-based education does not reduce alcohol-related harm, although public information and education-type programmes have a role in providing information and in increasing attention and acceptance of alcohol on political and public agendas. Making alcohol more expensive and less available, and banning alcohol advertising, are highly cost-effective strategies to reduce harm. In settings with high amounts of unrecorded production and consumption, increasing the proportion of alcohol that is taxed could be a more effective pricing policy than a simple increase in tax.
Sashidhar, R B
1993-10-01
Aflatoxin contamination of food and feed have gained global significance due to its deleterious effect on human and animal health and its importance in the international trade. The potential of aflatoxin as a carcinogen, mutagen, teratogen, and immunosuppressive agent is well documented. The problem of aflatoxin contamination of food and feed has led to the enactment of various legislation. However, meaningful strategies for implementation of this legislation is limited by nonavailability of simple, cost-effective method for screening and detection of aflatoxin under field conditions. Keeping in mind the analytical constraints in developing countries, a simple-to-operate, rapid, reliable, and cost-effective portable aflatoxin detection kit has been developed. The important components of the kit include a hand-held UV lamp (365 nm, 4 W output), a solvent blender (12,000 rpm) for toxin extraction, and adsorbent-coated dip-strips (polyester film) for detecting and quantifying aflatoxin. Analysis of variance indicates that there were no significant differences between various batches of dip-strips (p > 0.05). The minimum detection limit for aflatoxin B1 was 10 ppb per spot. The kit may find wide application as a research tool in public health laboratories, environmental monitoring agencies, and in the poultry industry.
Sashidhar, R B
1993-01-01
Aflatoxin contamination of food and feed have gained global significance due to its deleterious effect on human and animal health and its importance in the international trade. The potential of aflatoxin as a carcinogen, mutagen, teratogen, and immunosuppressive agent is well documented. The problem of aflatoxin contamination of food and feed has led to the enactment of various legislation. However, meaningful strategies for implementation of this legislation is limited by nonavailability of simple, cost-effective method for screening and detection of aflatoxin under field conditions. Keeping in mind the analytical constraints in developing countries, a simple-to-operate, rapid, reliable, and cost-effective portable aflatoxin detection kit has been developed. The important components of the kit include a hand-held UV lamp (365 nm, 4 W output), a solvent blender (12,000 rpm) for toxin extraction, and adsorbent-coated dip-strips (polyester film) for detecting and quantifying aflatoxin. Analysis of variance indicates that there were no significant differences between various batches of dip-strips (p > 0.05). The minimum detection limit for aflatoxin B1 was 10 ppb per spot. The kit may find wide application as a research tool in public health laboratories, environmental monitoring agencies, and in the poultry industry. Images FIGURE 1. PMID:8143644
Yu, Chunmei; Zhu, Zhenkun; Wang, Li; Wang, Qiuhong; Bao, Ning; Gu, Haiying
2014-03-15
Developing cost-effective and simple analysis tools is of vital importance for practical applications in bioanalysis. In this work, a new disposable electrochemical cell sensor with low cost and simple fabrication was proposed to study the electrochemical behavior of leukemia K562 cells and the effect of anticancer drugs on cell viability. The analytical device was integrated by using ITO glass as the substrate of working electrodes and paper as the electrolytic cell. The cyclic voltammetry of the K562 cells at the disposable electrode exhibited an irreversible anodic peak and the peak current is proportional to the cell number. This anodic peak is attributed to the oxidation of guanine in cells involving two protons per transfer of two electrons. For the drug sensitivity tests, arsenic trioxide and cyclophosphamide were added to cell culture media. As a result, the electrochemical responses of the K562 cells decreased significantly. The cytotoxicity curves and results obtained corresponded well with the results of CCK-8 assays. In comparison to conventional methods, the proposed method is simple, rapid and inexpensive. More importantly, the developed sensor is supposed to be a single-use disposable device and electrodes were prepared "as new" for each experiment. We think that such disposable electrodes with these characteristics are suitable for experimental study with cancer cells or other types of pathogens for disease diagnosis, drug selection and on-site monitoring. © 2013 Elsevier B.V. All rights reserved.
Value-Based Medicine: Dollars and Sense.
Erstad, Brian L
2016-02-01
With ever-increasing total healthcare expenditures and expenditures on new pharmaceuticals, there is a temptation to enact relatively simple silo-based, cost-control measures such as attempts to control a burgeoning health-system medication budget by limiting physician and ultimately patient access to medications without considering cost-effectiveness or overall value. Such an approach with a singular focus on dollars does not make sense. The challenge is to think beyond a pure dollars approach in a specialty of health care where the high cost of care is acknowledged but the dynamics are not always understood. This will take a thoughtful, coordinated effort by a team of dedicated health professionals that includes a clinical pharmacist with expertise in optimal and comprehensive medication management.
The use of cluster analysis techniques in spaceflight project cost risk estimation
NASA Technical Reports Server (NTRS)
Fox, G.; Ebbeler, D.; Jorgensen, E.
2003-01-01
Project cost risk is the uncertainty in final project cost, contingent on initial budget, requirements and schedule. For a proposed mission, a dynamic simulation model relying for some of its input on a simple risk elicitation is used to identify and quantify systemic cost risk.
24 CFR 200.97 - Adjustments resulting from cost certification.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Adjustments resulting from cost certification. (a) Fee simple site. Upon receipt of the mortgagor's... held under a leasehold or other interest less than a fee, the cost, if any, of acquiring the leasehold or other interest is considered an allowable expense which may be added to actual cost provided that...
Real-time Human Activity Recognition
NASA Astrophysics Data System (ADS)
Albukhary, N.; Mustafah, Y. M.
2017-11-01
The traditional Closed-circuit Television (CCTV) system requires human to monitor the CCTV for 24/7 which is inefficient and costly. Therefore, there’s a need for a system which can recognize human activity effectively in real-time. This paper concentrates on recognizing simple activity such as walking, running, sitting, standing and landing by using image processing techniques. Firstly, object detection is done by using background subtraction to detect moving object. Then, object tracking and object classification are constructed so that different person can be differentiated by using feature detection. Geometrical attributes of tracked object, which are centroid and aspect ratio of identified tracked are manipulated so that simple activity can be detected.
Javed, Muhammad; Dingley, John; Dickson, William; Shokrollahi, Kayvan
2014-02-01
Ventilated patients in ITU (intensive treatment unit) tend to be challenging to communicate with, especially patients who are being weaned. These patients usually have tracheostomy in situ and use means such as writing or letter boards to communicate. The situation becomes complex in patient groups that have burn injuries with bulky dressings and restricted upper limb function. We demonstrate a low cost, easy to use, potentially disposable system that can display words on any television screen via patient input device for such patient groups. The system consists of input device incorporated with Arduino microcontroller (an open-source electronics prototyping platform based on easy-to-use hardware and software intended for creating interactive environments) and 4 generously oversized control buttons. These are used to control the cursor movements (up, down, left, right) while a fifth has a "select" function. These are large enough to be pressed by an entire bandaged hand using gross upper limb movements only. A standard television is used to display menu containing the 26 letters of the alphabet and a flashing cursor. The patient selects the required letters/icon by moving the cursor and the words so created are displayed along the lower part of the screen for the carers to read. It is envisaged that anyone with basic craft skills should be able to construct this device. This device is a self-contained, cost-effective, simple, and open-source system that can be used effectively to bridge the communication gap with significant potential for patient care globally.
A low cost, simple, portable instrument for the measurement of infra-red reflectance of paints
NASA Astrophysics Data System (ADS)
Marson, F.
1982-05-01
The construction and design of a low cost, simple, portable infra-red reflectometer which can be used to estimate the reflectance of paint films in the 800 nm region is described. The infra-red reflectances of a range of lustreless, semigloss and gloss olive drab camouflage paints determined using this instrument are compared to those obtained using modified commercial equipment and to the reflectances measured at 800 nm using a Cary model 17 spectrophotometer. The new reflectometer was shown to be superior to the modified commercial instrument currently specified in Australian government paint specifications and to be capable of estimating the reflectance of olive drab paints to within about one per cent of the Cary derived reflectance values. The reflectance values for a range of 24 experimental coatings made with pigments of varying absorption in the infra-red region are used to illustrate the effect of the instrument's spectral response and the necessity of establishing a reliable working standard.
Harrison, Thomas C; Sigler, Albrecht; Murphy, Timothy H
2009-09-15
We describe a simple and low-cost system for intrinsic optical signal (IOS) imaging using stable LED light sources, basic microscopes, and commonly available CCD cameras. IOS imaging measures activity-dependent changes in the light reflectance of brain tissue, and can be performed with a minimum of specialized equipment. Our system uses LED ring lights that can be mounted on standard microscope objectives or video lenses to provide a homogeneous and stable light source, with less than 0.003% fluctuation across images averaged from 40 trials. We describe the equipment and surgical techniques necessary for both acute and chronic mouse preparations, and provide software that can create maps of sensory representations from images captured by inexpensive 8-bit cameras or by 12-bit cameras. The IOS imaging system can be adapted to commercial upright microscopes or custom macroscopes, eliminating the need for dedicated equipment or complex optical paths. This method can be combined with parallel high resolution imaging techniques such as two-photon microscopy.
Melvin, Neal R; Poda, Daniel; Sutherland, Robert J
2007-10-01
When properly applied, stereology is a very robust and efficient method to quantify a variety of parameters from biological material. A common sampling strategy in stereology is systematic random sampling, which involves choosing a random sampling [corrected] start point outside the structure of interest, and sampling relevant objects at [corrected] sites that are placed at pre-determined, equidistant intervals. This has proven to be a very efficient sampling strategy, and is used widely in stereological designs. At the microscopic level, this is most often achieved through the use of a motorized stage that facilitates the systematic random stepping across the structure of interest. Here, we report a simple, precise and cost-effective software-based alternative to accomplishing systematic random sampling under the microscope. We believe that this approach will facilitate the use of stereological designs that employ systematic random sampling in laboratories that lack the resources to acquire costly, fully automated systems.
NASA Astrophysics Data System (ADS)
Zhang, Yingzi; Hou, Yulong; Zhang, Yanjun; Hu, Yanjun; Zhang, Liang; Gao, Xiaolong; Zhang, Huixin; Liu, Wenyi
2018-02-01
A simple and low-cost continuous liquid-level sensor based on two parallel plastic optical fibers (POFs) in a helical structure is presented. The change in the liquid level is determined by measuring the side-coupling power in the passive fiber. The side-coupling ratio is increased by just filling the gap between the two POFs with ultraviolet-curable optical cement, making the proposed sensor competitive. The experimental results show that the side-coupling power declines as the liquid level rises. The sensitivity and the measurement range are flexible and affected by the geometric parameters of the helical structure. A higher sensitivity of 0.0208 μW/mm is acquired for a smaller curvature radius of 5 mm, and the measurement range can be expanded to 120 mm by enlarging the screw pitch to 40 mm. In addition, the reversibility and temperature dependence are studied. The proposed sensor is a cost-effective solution offering the advantages of a simple fabrication process, good reversibility, and compensable temperature dependence.
75 FR 57719 - Federal Acquisition Regulation; TINA Interest Calculations
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-22
... the term ``simple interest'' as the requirement for calculating interest for TINA cost impacts with.... Revising the date of the clause; and b. Removing from paragraph (e)(1) ``Simple interest'' and adding...) ``Simple interest'' and adding ``Interest compounded daily, as required by 26 U.S.C. 6622,'' in its place...
Modal cost analysis for simple continua
NASA Technical Reports Server (NTRS)
Hu, A.; Skelton, R. E.; Yang, T. Y.
1988-01-01
The most popular finite element codes are based upon appealing theories of convergence of modal frequencies. For example, the popularity of cubic elements for beam-like structures is due to the rapid convergence of modal frequencies and stiffness properties. However, for those problems in which the primary consideration is the accuracy of response of the structure at specified locations, it is more important to obtain accuracy in the modal costs than in the modal frequencies. The modal cost represents the contribution of a mode in the norm of the response vector. This paper provides a complete modal cost analysis for simple continua such as beam-like structures. Upper bounds are developed for mode truncation errors in the model reduction process and modal cost analysis dictates which modes to retain in order to reduce the model for control design purposes.
NASA Astrophysics Data System (ADS)
Milliken, Sarah; Fraser, Jeff; Poirier, Shawn; Hulse, John; Tay, Li-Lin
2018-05-01
Self-assembled multi-layered vertically aligned gold nanorod (AuNR) arrays have been fabricated by a simple preparation process that requires a balance between the particle concentration and the ionic strength of the solvent. An experimentally determined critical AuNR concentration of 2.0 nM and 50 mM NaCl produces well-ordered vertically aligned hexagonally close-packed AuNR arrays. We demonstrate surface treatment via UV Ozone cleaning of such samples to allow introduction of analyte molecules (benzenethiol and cannabinol) for effective surface enhanced Raman scattering detection. This is the first demonstration of the SERS analysis of cannabinol. This approach demonstrates a cost-effective, high-yield and simple fabrication route to SERS sensors with application in the screening for the cannabinoids.
Study of CdTe/CdS solar cell at low power density for low-illumination applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Devi, Nisha, E-mail: nishatanwer1989@gmail.com; Aziz, Anver, E-mail: aaziz@jmi.ac.in; Datta, Shouvik
In this paper, we numerically investigate CdTe/CdS PV cell properties using a simulation program Solar Cell Capacitance Simulator in 1D (SCAPS-1D). A simple structure of CdTe PV cell has been optimized to study the effect of temperature, absorber thickness and work function at very low incident power. Objective of this research paper is to build an efficient and cost effective solar cell for portable electronic devices such as portable computers and cell phones that work at low incident power because most of such devices work at diffused and reflected sunlight. In this report, we simulated a simple CdTe PV cellmore » at very low incident power, which gives good efficiency.« less
A simplified life-cycle cost comparison of various engines for small helicopter use
NASA Technical Reports Server (NTRS)
Civinskas, K. C.; Fishbach, L. M.
1974-01-01
A ten-year, life-cycle cost comparison is made of the following engines for small helicopter use: (1) simple turboshaft; (2) regenerative turboshaft; (3) compression-ignition reciprocator; (4) spark-ignited rotary; and (5) spark-ignited reciprocator. Based on a simplified analysis and somewhat approximate data, the simple turboshaft engine apparently has the lowest costs for mission times up to just under 2 hours. At 2 hours and above, the regenerative turboshaft appears promising. The reciprocating and rotary engines are less attractive, requiring from 10 percent to 80 percent more aircraft to have the same total payload capability as a given number of turbine powered craft. A nomogram was developed for estimating total costs of engines not covered in this study.
ERIC Educational Resources Information Center
Singh, Nirbhay N.; Lancioni, Giulio E.; Winton, Alan S. W.; Singh, Ashvind N.; Adkins, Angela D.; Singh, Judy
2008-01-01
The effects of a mindfulness-based procedure, called "Meditation on the Soles of the Feet", were evaluated as a cognitive-behavioral intervention for physical aggression in 6 offenders with mild intellectual disabilities. They were taught a simple meditation technique that required them to shift their attention and awareness from the precursors of…
Using a Client Survey to Support Continuous Improvement: An Australian Case Study in Managing Change
ERIC Educational Resources Information Center
Besch, Janice
2014-01-01
With the arrival of online survey tools that are low-cost, readily available and easy to administer, all organizations have access to one of the most effective mechanisms for determining quality improvement priorities and measuring progress towards achieving those priorities over time. This case study outlines the use made of this simple tool by a…
Li, Zhen; Zhu, Wenping; Zhang, Jinwen; Jiang, Jianhui; Shen, Guoli; Yu, Ruqin
2013-07-07
A label-free fluorescent DNA biosensor has been presented based on isothermal circular strand-displacement polymerization reaction (ICSDPR) combined with graphene oxide (GO) binding. The proposed method is simple and cost-effective with a low detection limit of 4 pM, which compares favorably with other GO-based homogenous DNA detection methods.
ERIC Educational Resources Information Center
Dahl, Robyn Mieko; Droser, Mary L.
2016-01-01
University earth science departments seeking to establish meaningful geoscience outreach programs often pursue large-scale, grant-funded programs. Although this type of outreach is highly successful, it is also extremely costly, and grant funding can be difficult to secure. Here, we present the Geoscience Education Outreach Program (GEOP), a…
An alternative to real estate ownership.
Scarborough, Sydney
2004-05-01
Partnering with healthcare real estate managers and investors is one way to generate capital, improve cash flow, and minimize the management costs of developing and operating outpatient properties without sacrificing control of strategic locations or facilities. Eight simple steps can help you identify and select viable strategic healthcare real estate partners and negotiate effective monetization (sale of property title) agreements with them.
Using Integration and Autonomy to Teach an Elementary Running Unit
ERIC Educational Resources Information Center
Sluder, J. Brandon; Howard-Shaughnessy, Candice
2015-01-01
Cardiovascular fitness is an important aspect of overall fitness, health, and wellness, and running can be an excellent lifetime physical activity. One of the most simple and effective means of exercise, running raises heart rate in a short amount of time and can be done with little to no cost for equipment. There are many benefits to running,…
ERIC Educational Resources Information Center
Bentley, Anne K.; Weaver, Gabriela C.; Russell, Cianan B.; Fornes, William L.; Choi, Kyoung-Shin; Shih, Susan M.
2007-01-01
A simple and cost-effective experiment for the development and characterization of semiconductors using Uv-vis spectroscopy is described. The study shows that the optical properties of ZnO films can be easily modified by forming Zn[subscript 1-x] Co[subscript x]O solid solutions via spray pyrolysis.
ERIC Educational Resources Information Center
Koesdjojo, Myra T.; Pengpumkiat, Sumate; Wu, Yuanyuan; Boonloed, Anukul; Huynh, Daniel; Remcho, Thomas P.; Remcho, Vincent T.
2015-01-01
We have developed a simple and direct method to fabricate paper-based microfluidic devices that can be used for a wide range of colorimetric assay applications. With these devices, assays can be performed within minutes to allow for quantitative colorimetric analysis by use of a widely accessible iPhone camera and an RGB color reader application…
Recently published papers: dying Swans and other stories.
Rose, Hannah; Venn, Richard
2006-01-01
The use of pulmonary artery catheters is under debate yet again. We look at two recent trials evaluating their impact on mortality. Our suspicions regarding obesity are proven and we also look at a simple, cost effective method of reducing ventilator-associated pneumonia. Finally, an intervention to improve the poor outcome associated with out-of hospital cardiac arrests is evaluated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutchison, Janine R.; Erikson, Rebecca L.; Sheen, Allison M.
Rapid, cost-effective bacterial detection systems are needed to respond to potential biothreat events. Here we report the use of smartphone-based microscopy in combination with a simple microfluidic incubation device to detect 5000 Bacillus anthracis spores in 3 hours. This field-deployable approach is compatible with real-time PCR for secondary confirmation.
NASA Astrophysics Data System (ADS)
Nohara, Mitsuo; Takeuchi, Yoshio; Takahata, Fumio
Up-link power control (UPC) is one of the essential technologies to provide efficient satellite communication systems operated at frequency bands above 10 GHz. A simple and cost-effective UPC scheme applicable to a demand assignment international business satellite communications system has been developed. This paper presents the UPC scheme, including the hardware implementation and its performance.
Dai, Yifan; Liu, Chung Chiun
2017-01-01
This research has developed a simple to use, cost effective sensor system for the detection of lead ions in tap water. An under-potential deposited bismuth sub-layer on a thin gold film based electrochemical sensor was designed, manufactured, and evaluated. Differential pulse voltammetry (DPV) measurement technique was employed in this detection. Tap water from the Cleveland, OH, USA regional water district was the test medium. Concentrations of lead ion in the range of 8 × 10−7 M to 5 × 10−4 M were evaluated, showing a good sensitivity over this concentration range. The calibration curve for the DPV measurements of lead ions in tap water showed excellent reproducibility with R2 value of 0.970. This DPV detection system required 3–6 min to complete the detection measurement. A longer measurement time of 6 min was used for the lower lead ion concentration. The selectivity of this lead ion sensor was very good, and Fe III, Cu II, Ni II, and Mg II at a concentration level of 5 × 10−4 M did not interfere with the lead ion measurement. PMID:28441356
Ozaki, Christiane Y; Silveira, Caio R F; Andrade, Fernanda B; Nepomuceno, Roberto; Silva, Anderson; Munhoz, Danielle D; Yamamoto, Bruno B; Luz, Daniela; Abreu, Patrícia A E; Horton, Denise S P Q; Elias, Waldir P; Ramos, Oscar H P; Piazza, Roxane M F
2015-01-01
Diarrhea is a prevalent pathological condition frequently associated to the colonization of the small intestine by enterotoxigenic Escherichia coli (ETEC) strains, known to be endemic in developing countries. These strains can produce two enterotoxins associated with the manifestation of clinical symptoms that can be used to detect these pathogens. Although several detection tests have been developed, minimally equipped laboratories are still in need of simple and cost-effective methods. With the aim to contribute to the development of such diagnostic approaches, we describe here two mouse hybridoma-derived single chain fragment variable (scFv) that were produced in E. coli against enterotoxins of ETEC strains. Recombinant scFv were developed against ETEC heat-labile toxin (LT) and heat-stable toxin (ST), from previously isolated hybridoma clones. This work reports their design, construction, molecular and functional characterization against LT and ST toxins. Both antibody fragments were able to recognize the cell-interacting toxins by immunofluorescence, the purified toxins by ELISA and also LT-, ST- and LT/ST-producing ETEC strains. The developed recombinant scFvs against LT and ST constitute promising starting point for simple and cost-effective ETEC diagnosis.
Lobo-Júnior, Eulício O; Gabriel, Ellen F M; Dos Santos, Rodrigo A; de Souza, Fabrício R; Lopes, Wanderson D; Lima, Renato S; Gobbi, Angelo L; Coltro, Wendell K T
2017-01-01
This study describes a simple, rapid, and cost-effective fabrication of PDMS electrophoresis microchips using poly(vinyl acetate) (PVAc) emulsion as photoresist master. High-relief microfluidic structures were defined on poly(vinyl acetate) previously deposited on printed circuit boards surfaces without cleanroom facilities and sophisticated instrumentation. After a UV exposure, channels with heights ranging from 30 to 140 μm were obtained by controlling the emulsion mass deposited on the master surface. The developing stage was performed using water rather than the organic solvents that are applied for conventional masks. The surface morphology was characterized by optical imaging, profilometry, and SEM. Based on the achieved results, the proposed method offers suitable reproducibility for the prototyping of electrophoresis microchips in PDMS. The feasibility of the resulting PDMS electrophoresis chips was successfully demonstrated with the separation of major inorganic cations within 100 s using a contactless conductivity detection system. The separation efficiencies ranged from ca. 67 900 to 125 600 plates/m. Due to the satisfactory performance and simplified instrumentation, we believe this fabrication protocol presents potential to be implemented in any chemical, biochemical, or biological laboratory. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
New simple and low-cost methods for periodic checks of Cyclone® Plus Storage Phosphor System.
Edalucci, Elisabetta; Maffione, Anna Margherita; Fornasier, Maria Rosa; De Denaro, Mario; Scian, Giovanni; Dore, Franca; Rubello, Domenico
2017-01-01
The recent large use of the Cyclone® Plus Storage Phosphor System, especially in European countries, as imaging system for quantification of radiochemical purity of radiopharmaceuticals raised the problem of setting the periodic controls as required by European Legislation. We described simple, low-cost methods for Cyclone® Plus quality controls, which can be useful to evaluate the performance measurement of this imaging system.
A Simple Label Switching Algorithm for Semisupervised Structural SVMs.
Balamurugan, P; Shevade, Shirish; Sundararajan, S
2015-10-01
In structured output learning, obtaining labeled data for real-world applications is usually costly, while unlabeled examples are available in abundance. Semisupervised structured classification deals with a small number of labeled examples and a large number of unlabeled structured data. In this work, we consider semisupervised structural support vector machines with domain constraints. The optimization problem, which in general is not convex, contains the loss terms associated with the labeled and unlabeled examples, along with the domain constraints. We propose a simple optimization approach that alternates between solving a supervised learning problem and a constraint matching problem. Solving the constraint matching problem is difficult for structured prediction, and we propose an efficient and effective label switching method to solve it. The alternating optimization is carried out within a deterministic annealing framework, which helps in effective constraint matching and avoiding poor local minima, which are not very useful. The algorithm is simple and easy to implement. Further, it is suitable for any structured output learning problem where exact inference is available. Experiments on benchmark sequence labeling data sets and a natural language parsing data set show that the proposed approach, though simple, achieves comparable generalization performance.
A simple and low-cost platform technology for producing pexiganan antimicrobial peptide in E. coli.
Zhao, Chun-Xia; Dwyer, Mirjana Dimitrijev; Yu, Alice Lei; Wu, Yang; Fang, Sheng; Middelberg, Anton P J
2015-05-01
Antimicrobial peptides, as a new class of antibiotics, have generated tremendous interest as potential alternatives to classical antibiotics. However, the large-scale production of antimicrobial peptides remains a significant challenge. This paper reports a simple and low-cost chromatography-free platform technology for producing antimicrobial peptides in Escherichia coli (E. coli). A fusion protein comprising a variant of the helical biosurfactant protein DAMP4 and the known antimicrobial peptide pexiganan is designed by joining the two polypeptides, at the DNA level, via an acid-sensitive cleavage site. The resulting DAMP4(var)-pexiganan fusion protein expresses at high level and solubility in recombinant E. coli, and a simple heat-purification method was applied to disrupt cells and deliver high-purity DAMP4(var)-pexiganan protein. Simple acid cleavage successfully separated the DAMP4 variant protein and the antimicrobial peptide. Antimicrobial activity tests confirmed that the bio-produced antimicrobial peptide has the same antimicrobial activity as the equivalent product made by conventional chemical peptide synthesis. This simple and low-cost platform technology can be easily adapted to produce other valuable peptide products, and opens a new manufacturing approach for producing antimicrobial peptides at large scale using the tools and approaches of biochemical engineering. © 2014 Wiley Periodicals, Inc.
An opportunity cost approach to sample size calculation in cost-effectiveness analysis.
Gafni, A; Walter, S D; Birch, S; Sendi, P
2008-01-01
The inclusion of economic evaluations as part of clinical trials has led to concerns about the adequacy of trial sample size to support such analysis. The analytical tool of cost-effectiveness analysis is the incremental cost-effectiveness ratio (ICER), which is compared with a threshold value (lambda) as a method to determine the efficiency of a health-care intervention. Accordingly, many of the methods suggested to calculating the sample size requirements for the economic component of clinical trials are based on the properties of the ICER. However, use of the ICER and a threshold value as a basis for determining efficiency has been shown to be inconsistent with the economic concept of opportunity cost. As a result, the validity of the ICER-based approaches to sample size calculations can be challenged. Alternative methods for determining improvements in efficiency have been presented in the literature that does not depend upon ICER values. In this paper, we develop an opportunity cost approach to calculating sample size for economic evaluations alongside clinical trials, and illustrate the approach using a numerical example. We compare the sample size requirement of the opportunity cost method with the ICER threshold method. In general, either method may yield the larger required sample size. However, the opportunity cost approach, although simple to use, has additional data requirements. We believe that the additional data requirements represent a small price to pay for being able to perform an analysis consistent with both concept of opportunity cost and the problem faced by decision makers. Copyright (c) 2007 John Wiley & Sons, Ltd.
Mental health economics, health service provision, and the practice of geriatric psychiatry.
Suh, Guk-Hee; Han, Changsu
2008-11-01
Economic evaluation is becoming more and more important as a means to assist policy makers in choosing the best intervention or treatment against a pervasive scarcity of resources relative to the demands. Health service provision and the practice of geriatric psychiatry are closely associated with costs and outcomes of health economics. Recently published literature raising unanswered questions in these areas is reviewed. Some studies on the costs, outcomes, and cost-effectiveness of certain interventions or treatments (e.g. respite care, home-visiting community service) compared with usual strategies show that these are not optimal in terms of health economics. The updated guidance by the National Institute for Health and Clinical Excellence that cholinesterase inhibitors should be used only for moderate severity dementia on the grounds of cost-effectiveness has been heavily criticized. Mental health provision for older people varies across 'developed' and 'developing' countries. Updated findings provide better understanding of recent progress and issues on mental health economics, health service provision, and the practice of geriatric psychiatry. The application of health economics to the field of mental health should make complicated issues simple and explicit. Constructive criticisms and scientific debates will hasten the development of better tools or methodologies to evaluate the cost-effectiveness of current and new interventions or treatments.
Rudis, Maria I; Touchette, Daniel R; Swadron, Stuart P; Chiu, Amy P; Orlinsky, Michael
2004-03-01
Oral phenytoin, intravenous phenytoin, and intravenous fosphenytoin are all commonly used for loading phenytoin in the emergency department (ED). The cost-effectiveness of each was compared for patients presenting with seizures and subtherapeutic phenytoin concentrations. A simple decision tree was developed to determine the treatment costs associated with each of 3 loading techniques. We determined effectiveness by comparing adverse event rates and by calculating the time to safe ED discharge. Time to safe ED discharge was defined as the time at which therapeutic concentrations of phenytoin (>or=10 mg/L) were achieved with an absence of any adverse events that precluded discharge. The comparative cost-effectiveness of alternatives to oral phenytoin was determined by combining net costs and number of adverse events, expressed as cost per adverse events avoided. Cost-effectiveness was also determined by comparing the net costs of each loading technique required to achieve the time to safe ED discharge, expressed as cost per hour of ED time saved. The outcomes and costs were primarily derived from a prospective, randomized controlled trial, augmented by time-motion studies and alternate-cost sources. Costs included the cost of drugs, supplies, and personnel. Analyses were also performed in scenarios incorporating labor costs and savings from using a lower-urgency area of the ED. The mean number of adverse events per patient for oral phenytoin, intravenous phenytoin, and intravenous fosphenytoin was 1.06, 1.93, and 2.13, respectively. Mean time to safe ED discharge in the 3 groups was 6.4 hours, 1.7 hours, and 1.3 hours. Cost per patient was 2.83 dollars, 21.16 dollars, and 175.19 dollars, respectively, and did not differ substantially in the Labor and Triage (lower-urgency area of ED) scenarios. When the measure of effectiveness was adverse events, oral phenytoin dominated intravenous phenytoin and intravenous fosphenytoin, with a lower cost and number of adverse events. With time to safe ED discharge as the outcome measure, the incremental cost-effectiveness ratios were 3.90 dollars and 387.27 dollars per hour of ED time saved for oral phenytoin versus intravenous phenytoin and for intravenous fosphenytoin versus intravenous phenytoin, respectively. Oral phenytoin is the most cost-effective loading method in most settings. Intravenous phenytoin is preferred if one is willing to pay an additional 20.65 dollars to 44.25 dollars per patient and willing to have more adverse events for a quicker average time to safe ED discharge. It is unlikely that intravenous fosphenytoin is justifiable in any setting.
Ljungberg, Elinor M; Carlsson, Katarina Steen; Dahlin, Lars B
2008-01-01
Background Health-care costs for hand and forearm injuries in young children are poorly documented. We examined costs in 533 children injured years 1996–2003. Methods Health-care costs and costs for lost productivity were retrospectively calculated in children from three catchment areas in Sweden. Seven case categories corresponding to alternative prevention strategies were constructed. Results Over time, diminishing number of ward days reduced the health-care cost per case. Among children, the cost of lost productivity due to parental leave was 14 percent of total cost. Fingertip injuries had low median costs but high total costs due to their frequency. Complex injuries by machine or rifle had high costs per case, and despite a low number of cases, total cost was high. Type of injury, surgery and physiotherapy sessions were associated with variations in health-care cost. Low age and ethnic background had a significant effect on number of ward days. Conclusion The costs per hand injury for children were lower compared to adults due to both lower health-care costs and to the fact that parents had comparatively short periods of absence from work. Frequent simple fingertip injuries and rare complex injuries induce high costs for society. Such costs should be related to costs for prevention of these injuries. PMID:18606018
Removing ammonium from water and wastewater using cost-effective adsorbents: A review.
Huang, Jianyin; Kankanamge, Nadeeka Rathnayake; Chow, Christopher; Welsh, David T; Li, Tianling; Teasdale, Peter R
2018-01-01
Ammonium is an important nutrient in primary production; however, high ammonium loads can cause eutrophication of natural waterways, contributing to undesirable changes in water quality and ecosystem structure. While ammonium pollution comes from diffuse agricultural sources, making control difficult, industrial or municipal point sources such as wastewater treatment plants also contribute significantly to overall ammonium pollution. These latter sources can be targeted more readily to control ammonium release into water systems. To assist policy makers and researchers in understanding the diversity of treatment options and the best option for their circumstance, this paper produces a comprehensive review of existing treatment options for ammonium removal with a particular focus on those technologies which offer the highest rates of removal and cost-effectiveness. Ion exchange and adsorption material methods are simple to apply, cost-effective, environmentally friendly technologies which are quite efficient at removing ammonium from treated water. The review presents a list of adsorbents from the literature, their adsorption capacities and other parameters needed for ammonium removal. Further, the preparation of adsorbents with high ammonium removal capacities and new adsorbents is discussed in the context of their relative cost, removal efficiencies, and limitations. Efficient, cost-effective, and environmental friendly adsorbents for the removal of ammonium on a large scale for commercial or water treatment plants are provided. In addition, future perspectives on removing ammonium using adsorbents are presented. Copyright © 2017. Published by Elsevier B.V.
Powell, Rebecca L R; Urbanski, Mateusz M; Burda, Sherri; Nanfack, Aubin; Kinge, Thompson; Nyambi, Phillipe N
2008-01-01
The predominance of unique recombinant forms (URFs) of HIV-1 in Cameroon suggests that dual infection, the concomitant or sequential infection with genetically distinct HIV-1 strains, occurs frequently in this region; yet, identifying dual infection among large HIV cohorts in local, resource-limited settings is uncommon, since this generally relies on labor-intensive and costly sequencing methods. Consequently, there is a need to develop an effective, cost-efficient method appropriate to the developing world to identify these infections. In the present study, the heteroduplex assay (HDA) was used to verify dual or single infection status, as shown by traditional sequence analysis, for 15 longitudinally sampled study subjects from Cameroon. Heteroduplex formation, indicative of a dual infection, was identified for all five study subjects shown by sequence analysis to be dually infected. Conversely, heteroduplex formation was not detectable for all 10 HDA reactions of the singly infected study subjects. These results suggest that the HDA is a simple yet powerful and inexpensive tool for the detection of both intersubtype and intrasubtype dual infections, and that the HDA harbors significant potential for reliable, high-throughput screening for dual infection. As these infections and the recombinants they generate facilitate leaps in HIV-1 evolution, and may present major challenges for treatment and vaccine design, this assay will be critical for monitoring the continuing pandemic in regions of the world where HIV-1 viral diversity is broad.
Laser Speckle Photography: Some Simple Experiments for the Undergraduate Laboratory.
ERIC Educational Resources Information Center
Bates, B.; And Others
1986-01-01
Describes simple speckle photography experiments which are easy to set up and require only low cost standard laboratory equipment. Included are procedures for taking single, double, and multiple exposures. (JN)
Assessing map accuracy in a remotely sensed, ecoregion-scale cover map
Edwards, T.C.; Moisen, Gretchen G.; Cutler, D.R.
1998-01-01
Landscape- and ecoregion-based conservation efforts increasingly use a spatial component to organize data for analysis and interpretation. A challenge particular to remotely sensed cover maps generated from these efforts is how best to assess the accuracy of the cover maps, especially when they can exceed 1000 s/km2 in size. Here we develop and describe a methodological approach for assessing the accuracy of large-area cover maps, using as a test case the 21.9 million ha cover map developed for Utah Gap Analysis. As part of our design process, we first reviewed the effect of intracluster correlation and a simple cost function on the relative efficiency of cluster sample designs to simple random designs. Our design ultimately combined clustered and subsampled field data stratified by ecological modeling unit and accessibility (hereafter a mixed design). We next outline estimation formulas for simple map accuracy measures under our mixed design and report results for eight major cover types and the three ecoregions mapped as part of the Utah Gap Analysis. Overall accuracy of the map was 83.2% (SE=1.4). Within ecoregions, accuracy ranged from 78.9% to 85.0%. Accuracy by cover type varied, ranging from a low of 50.4% for barren to a high of 90.6% for man modified. In addition, we examined gains in efficiency of our mixed design compared with a simple random sample approach. In regard to precision, our mixed design was more precise than a simple random design, given fixed sample costs. We close with a discussion of the logistical constraints facing attempts to assess the accuracy of large-area, remotely sensed cover maps.
Assessing the costs attributed to project delay during project pre-construction stages
DOT National Transportation Integrated Search
2016-03-01
This project for the Texas Department of Transportation (TxDOT) developed a simple but sound : methodology for estimating the cost of delaying most types of highway projects. Researchers considered the : cost of delays during the pre-construction pha...
Assessing the costs attributed to project delay during project pre-construction stages.
DOT National Transportation Integrated Search
2016-03-01
This project for the Texas Department of Transportation (TxDOT) developed a simple but sound : methodology for estimating the cost of delaying most types of highway projects. Researchers considered the : cost of delays during the pre-construction pha...
A novel medical information management and decision model for uncertain demand optimization.
Bi, Ya
2015-01-01
Accurately planning the procurement volume is an effective measure for controlling the medicine inventory cost. Due to uncertain demand it is difficult to make accurate decision on procurement volume. As to the biomedicine sensitive to time and season demand, the uncertain demand fitted by the fuzzy mathematics method is obviously better than general random distribution functions. To establish a novel medical information management and decision model for uncertain demand optimization. A novel optimal management and decision model under uncertain demand has been presented based on fuzzy mathematics and a new comprehensive improved particle swarm algorithm. The optimal management and decision model can effectively reduce the medicine inventory cost. The proposed improved particle swarm optimization is a simple and effective algorithm to improve the Fuzzy interference and hence effectively reduce the calculation complexity of the optimal management and decision model. Therefore the new model can be used for accurate decision on procurement volume under uncertain demand.
Acute exacerbations of chronic bronchitis: a pharmacoeconomic review of antibacterial use.
Morris, Stephen; Anderson, Pippa; Irwin, Debra E
2002-01-01
Chronic bronchitis is a common problem affecting a large proportion of the adult population. People with chronic bronchitis are subject to recurrent attacks of bronchial inflammation called acute exacerbations of chronic bronchitis (AECBs). In patients with AECBs, symptoms may worsen due to a bacterial infection; the exacerbation is then known as an acute bacterial exacerbation of chronic bronchitis (ABECB). ABECBs are thought to be controllable through the use of antibacterial agents. In this paper we review current evidence on the cost of chronic bronchitis and AECBs, the cost effectiveness of antibacterials in the management of ABECB, and the factors that may affect the cost-effectiveness of antibacterials in the management of ABECB. We find that the number of economic evaluations conducted in this area is small. Of the few economic evaluations that have been conducted there has been only one prospective economic evaluation based on a clinical trial. The remainder are simple decision analysis-based modelling studies or retrospective database studies. Our principle findings are as follows: a key factor affecting the cost-effective use of antibacterials in the management of ABECB is the definitive diagnosis of the condition. Unfortunately, diagnosing a bacterial cause of an AECB is difficult, which presents problems in ensuring that antibacterials are not prescribed unnecessarily;current evidence suggests but does not prove that use of more effective but more costly first-line antibacterials may be relatively cost effective and may minimise overall expenditure by reducing the high costs associated with treatment failure;chronic bronchitis and AECB have a significant and negative physical and psychological effect on health-related quality of life. In conclusion, the small number of economic evaluations conducted in this area, coupled with the nature of the design of these studies, precludes a definitive statement recommending which specific antibacterial should be preferred on cost-effectiveness grounds for the management of ABECB. On the basis of our findings we suggest some topics for further research.
Segmenting high-cost Medicare patients into potentially actionable cohorts.
Joynt, Karen E; Figueroa, Jose F; Beaulieu, Nancy; Wild, Robert C; Orav, E John; Jha, Ashish K
2017-03-01
Providers are assuming growing responsibility for healthcare spending, and prior studies have shown that spending is concentrated in a small proportion of patients. Using simple methods to segment these patients into clinically meaningful subgroups may be a useful and accessible strategy for targeting interventions to control costs. Using Medicare fee-for-service claims from 2011 (baseline year, used to determine comorbidities and subgroups) and 2012 (spending year), we used basic demographics and comorbidities to group beneficiaries into 6 cohorts, defined by expert opinion and consultation: under-65 disabled/ESRD, frail elderly, major complex chronic, minor complex chronic, simple chronic, and relatively healthy. We considered patients in the highest 10% of spending to be "high-cost." 611,245 beneficiaries were high-cost; these patients were less often white (76.2% versus 80.9%) and more often dually-eligible (37.0% versus 18.3%). By segment, frail patients were the most likely (46.2%) to be high-cost followed by the under-65 (14.3%) and major complex chronic groups (11.1%); fewer than 5% of the beneficiaries in the other cohorts were high-cost in the spending year. The frail elderly ($70,196) and under-65 disabled/ESRD ($71,210) high-cost groups had the highest spending; spending in the frail high-cost group was driven by inpatient ($23,704) and post-acute care ($24,080), while the under 65-disabled/ESRD spent more through part D costs ($23,003). Simple criteria can segment Medicare beneficiaries into clinically meaningful subgroups with different spending profiles. Under delivery system reform, interventions that focus on frail or disabled patients may have particularly high value as providers seek to reduce spending. IV. Copyright © 2016 Elsevier Inc. All rights reserved.
Functional brain and age-related changes associated with congruency in task switching
Eich, Teal S.; Parker, David; Liu, Dan; Oh, Hwamee; Razlighi, Qolamreza; Gazes, Yunglin; Habeck, Christian; Stern, Yaakov
2016-01-01
Alternating between completing two simple tasks, as opposed to completing only one task, has been shown to produce costs to performance and changes to neural patterns of activity, effects which are augmented in old age. Cognitive conflict may arise from factors other than switching tasks, however. Sensorimotor congruency (whether stimulus-response mappings are the same or different for the two tasks) has been shown to behaviorally moderate switch costs in older, but not younger adults. In the current study, we used fMRI to investigate the neurobiological mechanisms of response-conflict congruency effects within a task switching paradigm in older (N=75) and younger (N=62) adults. Behaviorally, incongruency moderated age-related differences in switch costs. Neurally, switch costs were associated with greater activation in the dorsal attention network for older relative to younger adults. We also found that older adults recruited an additional set of brain areas in the ventral attention network to a greater extent than did younger adults to resolve congruency-related response-conflict. These results suggest both a network and an age-based dissociation between congruency and switch costs in task switching. PMID:27520472
Adhikari, Bishwa B; Goodson, James L; Chu, Susan Y; Rota, Paul A; Meltzer, Martin I
2016-12-01
Currently available measles vaccines are administered by subcutaneous injections and require reconstitution with a diluent and a cold chain, which is resource intensive and challenging to maintain. To overcome these challenges and potentially increase vaccination coverage, microneedle patches are being developed to deliver the measles vaccine. This study compares the cost-effectiveness of using microneedle patches with traditional vaccine delivery by syringe-and-needle (subcutaneous vaccination) in children's measles vaccination programs. We built a simple spreadsheet model to compute the vaccination costs for using microneedle patch and syringe-and-needle technologies. We assumed that microneedle vaccines will be, compared with current vaccines, more heat stable and require less expensive cool chains when used in the field. We used historical data on the incidence of measles among communities with low measles vaccination rates. The cost of microneedle vaccination was estimated at US$0.95 (range US$0.71-US$1.18) for the first dose, compared with US$1.65 (range US$1.24-US$2.06) for the first dose delivered by subcutaneous vaccination. At 95 % vaccination coverage, microneedle patch vaccination was estimated to cost US$1.66 per measles case averted (range US$1.24-US$2.07) compared with an estimated cost of US$2.64 per case averted (range US$1.98-US$3.30) using subcutaneous vaccination. Use of microneedle patches may reduce costs; however, the cost-effectiveness of patches would depend on the vaccine recipients' acceptability and vaccine effectiveness of the patches relative to the existing conventional vaccine-delivery method. This study emphasizes the need to continue research and development of this vaccine-delivery method that could boost measles elimination efforts through improved access to vaccines and increased vaccination coverage.
Yu, Yangyang R; Abbas, Paulette I; Smith, Carolyn M; Carberry, Kathleen E; Ren, Hui; Patel, Binita; Nuchtern, Jed G; Lopez, Monica E
2016-12-01
As reimbursement programs shift to value-based payment models emphasizing quality and efficient healthcare delivery, there exists a need to better understand process management to unearth true costs of patient care. We sought to identify cost-reduction opportunities in simple appendicitis management by applying a time-driven activity-based costing (TDABC) methodology to this high-volume surgical condition. Process maps were created using medical record time stamps. Labor capacity cost rates were calculated using national median physician salaries, weighted nurse-patient ratios, and hospital cost data. Consumable costs for supplies, pharmacy, laboratory, and food were derived from the hospital general ledger. Time-driven activity-based costing resulted in precise per-minute calculation of personnel costs. Highest costs were in the operating room ($747.07), hospital floor ($388.20), and emergency department ($296.21). Major contributors to length of stay were emergency department evaluation (270min), operating room availability (395min), and post-operative monitoring (1128min). The TDABC model led to $1712.16 in personnel costs and $1041.23 in consumable costs for a total appendicitis cost of $2753.39. Inefficiencies in healthcare delivery can be identified through TDABC. Triage-based standing delegation orders, advanced practice providers, and same day discharge protocols are proposed cost-reducing interventions to optimize value-based care for simple appendicitis. II. Copyright © 2016 Elsevier Inc. All rights reserved.
Greenwell, T J; Castle, C; Andrich, D E; MacDonald, J T; Nicol, D L; Mundy, A R
2004-07-01
We developed an algorithm for the management of urethral stricture based on cost-effectiveness. United Kingdom medical and hospital costs associated with the current management of urethral stricture were calculated using private medical insurance schedules of reimbursement and clean intermittent self-catheterization supply costs. These costs were applied to 126 new patients treated endoscopically for urethral stricture in a general urological setting between January 1, 1991 and December 31, 1999. Treatment failure was defined as recurrent symptomatic stricture requiring further operative intervention following initial intervention. Mean followup available was 25 months (range 1 to 132). The costs were urethrotomy/urethral dilation 2,250.00 pounds sterling (3,375.00 dollars, ratio 1.00), simple 1-stage urethroplasty 5,015.00 pounds sterling (7,522.50 dollars, ratio 2.23), complex 1-stage urethroplasty 5,335.00 pounds sterling (8,002.50 dollars, ratio 2.37) and 2-stage urethroplasty 10,370 pounds sterling (15,555.00 dollars, ratio 4.61). Of the 126 patients assessed 60 (47.6%) required more than 1 endoscopic retreatments (mean 3.13 each), 50 performed biweekly clean intermittent self-catheterization and 7 underwent urethroplasty during followup. The total cost per patient for all 126 patients for stricture treatment during followup was 6,113 pounds sterling (9,170 dollars). This cost was calculated by multiplying procedure cost by the number of procedures performed. A strategy of urethrotomy or urethral dilation as first line treatment, followed by urethroplasty for recurrence yielded a total cost per patient of 5,866 pounds sterling (8,799 dollars). A strategy of initial urethrotomy or urethral dilation followed by urethroplasty in patients with recurrent stricture proves to be the most cost-effective strategy. This financially based strategy concurs with evidence based best practice for urethral stricture management.
Economical Analysis on Prophylaxis, Diagnosis, and Treatment of Periprosthetic Infections
Fernandez-Fairen, Mariano; Torres, Ana; Menzie, Ann; Hernandez-Vaquero, Daniel; Fernandez-Carreira, José Manuel; Murcia-Mazon, Antonio; Guerado, Enrique; Merzthal, Luis
2013-01-01
The economic burden of periprosthetic infections is enormous, but the number of economic studies dealing with this issue is very scarce. This review tries to know the economic literature existing, assess the value of current data, and recognize the less costly and more effective procedures for prevention, diagnosis and treatment of periprosthetic infections. Forty five studies meeting the inclusion criteria and adhering to the quality criteria used were carefully analyzed to extract the economic data of relevance in evaluating the magnitude of problem and the more cost-effective solutions. However, because the heterogeneity and the low-quality of most of these studies meta-analytical technique has not been possible. Instead, the studies have been reviewed descriptively. Optimizing the antibiotic use in the prevention and treatment of periprosthetic infection, combined with systemic and behavioral changes in the operating room; detecting and treating the high-risk groups; a quick, simple, reliable, safe, and cost-effective diagnosis, and the rationale management of the instituted infection, specifically using the different procedures according to each particular case, could allow to improve outcomes and produce the highest quality of life for patients and the lowest economic impact. Nevertheless, the cost effectiveness of different interventions to prevent and to treat the periprosthetic infection remains unclear. PMID:24082966
Immersion frying for the thermal drying of sewage sludge: an economic assessment.
Peregrina, Carlos; Rudolph, Victor; Lecomte, Didier; Arlabosse, Patricia
2008-01-01
This paper presents an economic study of a novel thermal fry-drying technology which transforms sewage sludge and recycled cooking oil (RCO) into a solid fuel. The process is shown to have significant potential advantage in terms of capital costs (by factors of several times) and comparable operating costs. Three potential variants of the process have been simulated and costed in terms of both capital and operating requirements for a commercial scale of operation. The differences are in the energy recovery systems, which include a simple condensation of the evaporated water and two different heat pump configurations. Simple condensation provides the simplest process, but the energy efficiency gain of an open heat pump offset this, making it economically somewhat more attractive. In terms of operating costs, current sludge dryers are dominated by maintenance and energy requirements, while for fry-drying these are comparatively small. Fry-drying running costs are dominated by provision of makeup waste oil. Cost reduction could focus on cheaper waste oil, e.g. from grease trap waste.
ERIC Educational Resources Information Center
Ayed, Ahmad; Eqtait, Faeda; Harazneh, Lubna; Fashafsheh, Imad; Nazzal, Sewar; Talahmeh, Bian; Hajar, Deena; Awawdeh, Rrawan
2015-01-01
Background: Breast self-examination is a simple, very low cost, noninvasive with no special material/tool requirements; and it is an effective diagnostic method for breast cancer which only takes five minutes to apply. Aim of the Study: The study aimed to assess the level of BSE knowledge, attitude, and practice among female nursing students in…
Air-bridged Ohmic contact on vertically aligned si nanowire arrays: application to molecule sensors.
Han, Hee; Kim, Jungkil; Shin, Ho Sun; Song, Jae Yong; Lee, Woo
2012-05-02
A simple, cost-effective, and highly reliable method for constructing an air-bridged electrical contact on large arrays of vertically aligned nanowires was developed. The present method may open up new opportunities for developing advanced nanowire-based devices for energy harvest and storage, power generation, and sensing applications. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Microwave-Assisted Synthesis of Red-Light Emitting Au Nanoclusters with the Use of Egg White
ERIC Educational Resources Information Center
Tian, Jinghan; Yan, Lei; Sang, Aohua; Yuan, Hongyan; Zheng, Baozhan; Xiao, Dan
2014-01-01
We developed a simple, cost-effective, and eco-friendly method to synthesize gold nanoclusters (AuNCs) with red fluorescence. The experiment was performed using HAuCl[subscript 4], egg white, Na[subscript 2]CO[subscript 3] (known as soda ash or washing soda), and a microwave oven. In our experiment, fluorescent AuNCs were prepared within a…
Synthetic Nanovaccines Against Respiratory Pathogens (SYNARP)
2010-07-01
nanoscale delivery systems can provide versatile platforms for development of effective, safe, and cost-efficient vaccines. The materials used in these...polymers was estimated by calculating the degree of polymerization (DP) using the peak area normalized with the protons representing hydrolyzed and...structures can be prototyped very easily and rapidly using a simple mask. In this work, the desired 5x5 array of discrete wells was created using
Pre-Packaged Commercial PACE Financing Solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wallander, Michael
The objective of this project was to demonstrate a more streamlined method for facilitating commercial property assessed clean energy (PACE) retrofits. The Recipient aimed to prove that energy efficiency performance of simple, pre-packaged technologies (e.g., lighting and heating, ventilation and air conditioning (HVAC)) can be accurately estimated without the need for a detailed energy audit. A successful project would inspire consumer confidence in undertaking cost-effective retrofits.
The Instability of Instability
1991-05-01
thermodynamic principles, changes cannot be effected without some cost. The decision - making associated with Model I can be viewed as rational behavior. Consider...number Democratic simple majority voting is perhaps the most widely used method of group decision making i;i our time. Current theory, based on...incorporate any of several plausible characteristics of decision - making , then the instability theorems do not hold and in fact the probability of
ERIC Educational Resources Information Center
Downs, Nathan; Parisi, Alfio
2010-01-01
A method is described for building a cost effective digital circuit capable of monitoring the solar radiation incident upon a remote solar cell. The circuit is built in two sections, the first, digitises the analogue voltage produced by the solar cell at a remote location and transmits the received signal to the second receiver circuit which…
ERIC Educational Resources Information Center
Gold, J.; Aitken, C. K.; Dixon, H. G.; Lim, M. S. C.; Gouillou, M.; Spelman, T.; Wakefield, M.; Hellard, M. E.
2011-01-01
Mobile phone text messages (SMS) are a promising method of health promotion, but a simple and low cost way to obtain phone numbers is required to reach a wide population. We conducted a randomised controlled trial with simultaneous brief interventions to (i) evaluate effectiveness of messages related to safer sex and sun safety and (ii) pilot the…
2011-07-26
residual spray of insecticides . Since the early 1900s [3,4], it has been known that the most cost - effective means of preventing mosquito-borne disease is...buildings usually accomplished with indoor residual or space spray are often hampered by limited access into homes and resource limitations [5]. On the...and indoor residual spray has focused mainly on the lethal actions of chemicals [6,7]. However, research shows that there are other chemical actions
[Sclerotherapy of hydrocele and cord cyst with polidocanol. Efficiency study].
Merenciano Cortina, F J; Rafie Mazketli, W; Amat Cecilia, M; Romero Pérez, P
2001-01-01
Checking the efficiency (cost/benefit) of the sclerotherapy with polidocanol in our country for the treatment of hydrocele and epididymal cyst. We studies 86 patients with this diagnosis from may of 1995, until april of 2000. We have applied the costs for process according to the indicators of administration-cost our hospital in the year 1999. 79 patient completed the protocol. The overall cure rate was 83.87% with sclerotherapy; 42.3% with first one treatment. Only a 4.5% of the patients had significant pain and a 7.4% others complications. There were necessaries 1.5 sclerotherapies of mean for curation, resulting this treatment 4.78 more cheaper than surgery. The sclerotherapy with polidocanol of the hydrocele or epididymal cyst are an effective treatment, sure, simple, reasonably comfortable and fundamentally, economical.
Proactive replica checking to assure reliability of data in cloud storage with minimum replication
NASA Astrophysics Data System (ADS)
Murarka, Damini; Maheswari, G. Uma
2017-11-01
The two major issues for cloud storage systems are data reliability and storage costs. For data reliability protection, multi-replica replication strategy which is used mostly in current clouds acquires huge storage consumption, leading to a large storage cost for applications within the loud specifically. This paper presents a cost-efficient data reliability mechanism named PRCR to cut back the cloud storage consumption. PRCR ensures data reliability of large cloud information with the replication that might conjointly function as a price effective benchmark for replication. The duplication shows that when resembled to the standard three-replica approach, PRCR will scale back to consume only a simple fraction of the cloud storage from one-third of the storage, thence considerably minimizing the cloud storage price.
A Novel High-Efficiency Rear-Contact Solar Cell with Bifacial Sensitivity
NASA Astrophysics Data System (ADS)
Hezel, R.
At present, wafer-based silicon solar cells have a share of more than 90% of the photovoltaic market. Despite rapid growth in the manufacturing volume, accompanied by a significant drop in the module selling price, the high costs currently associated with photovoltaic power generation are one of the most important obstacles to widespread global use of solar electricity. Up to a certain level, a higher production volume is a key driver in cost reduction. However, apart from a drastic reduction of the silicon wafer thickness in conjunction with improved light-trapping schemes, innovative processing sequences combining very high solar cell efficiencies with simple and cost-effective fabrication techniques are needed to become competitive with conventional energy sources and thus to move solar energy from niche to mainstream.
Ranked set sampling: cost and optimal set size.
Nahhas, Ramzi W; Wolfe, Douglas A; Chen, Haiying
2002-12-01
McIntyre (1952, Australian Journal of Agricultural Research 3, 385-390) introduced ranked set sampling (RSS) as a method for improving estimation of a population mean in settings where sampling and ranking of units from the population are inexpensive when compared with actual measurement of the units. Two of the major factors in the usefulness of RSS are the set size and the relative costs of the various operations of sampling, ranking, and measurement. In this article, we consider ranking error models and cost models that enable us to assess the effect of different cost structures on the optimal set size for RSS. For reasonable cost structures, we find that the optimal RSS set sizes are generally larger than had been anticipated previously. These results will provide a useful tool for determining whether RSS is likely to lead to an improvement over simple random sampling in a given setting and, if so, what RSS set size is best to use in this case.
The Location of Sales Offices and the Attraction of Cities.
ERIC Educational Resources Information Center
Holmes, Thomas J.
2005-01-01
This paper examines how manufacturers locate sales offices across cities. Sales office costs are assumed to have four components: a fixed cost, a frictional cost for out-of-town sales, a cost-reducing knowledge spillover related to city size, and an idiosyncratic match quality for each firm-city pair. A simple theoretical model is developed and is…
The impact of Pulpwood Rail Freight Costs on the Minnesota-Wisconsin Pulpwood Market
David C. Lothner
1976-01-01
Transportation costs affect the marketing and utilization of pulpwood. Their impact on the procurement and utilization of pulpwood often prove difficult to measure because deriving an average annual measure of the transportation cost is difficult. This note, by means of a simple index method for measuring regional interstate pulpwood rail freight costs, illustrates...
Harbert, Simeon D; Jaiswal, Tushar; Harley, Linda R; Vaughn, Tyler W; Baranak, Andrew S
2013-01-01
The low cost, simple, robust, mobile, and easy to use Mobile Motion Capture (MiMiC) system is presented and the constraints which guided the design of MiMiC are discussed. The MiMiC Android application allows motion data to be captured from kinematic modules such as Shimmer 2r sensors over Bluetooth. MiMiC is cost effective and can be used for an entire day in a person's daily routine without being intrusive. MiMiC is a flexible motion capture system which can be used for many applications including fall detection, detection of fatigue in industry workers, and analysis of individuals' work patterns in various environments.
Cost-effectiveness of rapid syphilis screening in prenatal HIV testing programs in Haiti.
Schackman, Bruce R; Neukermans, Christopher P; Fontain, Sandy N Nerette; Nolte, Claudine; Joseph, Patrice; Pape, Jean W; Fitzgerald, Daniel W
2007-05-01
New rapid syphilis tests permit simple and immediate diagnosis and treatment at a single clinic visit. We compared the cost-effectiveness, projected health outcomes, and annual cost of screening pregnant women using a rapid syphilis test as part of scaled-up prenatal testing to prevent mother-to-child HIV transmission in Haiti. A decision analytic model simulated health outcomes and costs separately for pregnant women in rural and urban areas. We compared syphilis syndromic surveillance (rural standard of care), rapid plasma reagin test with results and treatment at 1-wk follow-up (urban standard of care), and a new rapid test with immediate results and treatment. Test performance data were from a World Health Organization-Special Programme for Research and Training in Tropical Diseases field trial conducted at the GHESKIO Center Groupe Haitien d'Etude du Sarcome de Kaposi et des Infections Opportunistes in Port-au-Prince. Health outcomes were projected using historical data on prenatal syphilis treatment efficacy and included disability-adjusted life years (DALYs) of newborns, congenital syphilis cases, neonatal deaths, and stillbirths. Cost-effectiveness ratios are in US dollars/DALY from a societal perspective; annual costs are in US dollars from a payer perspective. Rapid testing with immediate treatment has a cost-effectiveness ratio of $6.83/DALY in rural settings and $9.95/DALY in urban settings. Results are sensitive to regional syphilis prevalence, rapid test sensitivity, and the return rate for follow-up visits. Integrating rapid syphilis testing into a scaled-up national HIV testing and prenatal care program would prevent 1,125 congenital syphilis cases and 1,223 stillbirths or neonatal deaths annually at a cost of $525,000. In Haiti, integrating a new rapid syphilis test into prenatal care and HIV testing would prevent congenital syphilis cases and stillbirths, and is cost-effective. A similar approach may be beneficial in other resource-poor countries that are scaling up prenatal HIV testing.
Public Housing: A Tailored Approach to Energy Retrofits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dentz, J.; Conlin, F.; Podorson, D.
2014-06-01
Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 PHAs across the country indicated that there is a high level of interest in developing low cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations at themore » time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation in ten housing units. Reductions in average air leakage were 16-20% and duct leakage reductions averaged 38%. Total source energy consumption savings was estimated at 6-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of unit per year nationally.« less
Introducing criteria based audit into Ugandan maternity units.
Weeks, A D; Alia, G; Ononge, S; Mutungi, A; Otolorin, E O; Mirembe, F M
2004-02-01
Maternal mortality in Uganda has remained unchanged at 500/100 000 over the past 10 years despite concerted efforts to improve the standard of maternity care. It is especially difficult to improve standards in rural areas, where there is little money for improvements. Furthermore, staff may be isolated, poorly paid, disempowered, lacking in morale, and have few skills to bring about change. Training programme to introduce criteria based audit into rural Uganda. Makerere University Medical School, Mulago Hospital (large government teaching hospital in Kampala), and Mpigi District (rural area with 10 small health centres around a district hospital). Didactic teaching about criteria based audit followed by practical work in own units, with ongoing support and follow up workshops. Improvements were seen in many standards of care. Staff showed universal enthusiasm for the training; many staff produced simple, cost-free improvements in their standard of care. Teaching of criteria based audit to those providing health care in developing countries can produce low cost improvements in the standards of care. Because the method is simple and can be used to provide improvements even without new funding, it has the potential to produce sustainable and cost effective changes in the standard of health care. Follow up is needed to prevent a waning of enthusiasm with time.
Sail Plan Configuration Optimization for a Modern Clipper Ship
NASA Astrophysics Data System (ADS)
Gerritsen, Margot; Doyle, Tyler; Iaccarino, Gianluca; Moin, Parviz
2002-11-01
We investigate the use of gradient-based and evolutionary algorithms for sail shape optimization. We present preliminary results for the optimization of sheeting angles for the rig of the future three-masted clipper yacht Maltese Falcon. This yacht will be equipped with square-rigged masts made up of yards of circular arc cross sections. This design is especially attractive for megayachts because it provides a large sail area while maintaining aerodynamic and structural efficiency. The rig remains almost rigid in a large range of wind conditions and therefore a simple geometrical model can be constructed without accounting for the true flying shape. The sheeting angle optimization studies are performed using both gradient-based cost function minimization and evolutionary algorithms. The fluid flow is modeled by the Reynolds-averaged Navier-Stokes equations with the Spallart-Allmaras turbulence model. Unstructured non-conforming grids are used to increase robustness and computational efficiency. The optimization process is automated by integrating the system components (geometry construction, grid generation, flow solver, force calculator, optimization). We compare the optimization results to those done previously by user-controlled parametric studies using simple cost functions and user intuition. We also investigate the effectiveness of various cost functions in the optimization (driving force maximization, ratio of driving force to heeling force maximization).
Are “knife and fork” good enough for day case surgery of resistant tennis elbow?
Govindaswamy, Raja; Elbouni, Tariq; Chambler, Andrew F. W.
2008-01-01
This observational retrospective study was performed on 22 consecutive patients treated surgically in a day surgery unit for resistant tennis elbow to ascertain the effectiveness of the “knife and fork” procedure. All patients had an unfavourable response to nonsurgical treatment lasting at least six months. A simple and inexpensive “knife and fork” technique yielded excellent results in 90.5% of patients and a high percentage (95.2%) of satisfied patients at an average follow-up of two years. There were no fair or poor results and no complications. We conclude that the “knife and fork” technique is a simple and dependable day case procedure. In the present National Health Service (NHS) era of tariff and “payment by results”, this approach is more cost effective than an arthroscopic alternative. PMID:19096844
Milliken, Sarah; Fraser, Jeff; Poirier, Shawn; Hulse, John; Tay, Li-Lin
2018-05-05
Self-assembled multi-layered vertically aligned gold nanorod (AuNR) arrays have been fabricated by a simple preparation process that requires a balance between the particle concentration and the ionic strength of the solvent. An experimentally determined critical AuNR concentration of 2.0nM and 50mM NaCl produces well-ordered vertically aligned hexagonally close-packed AuNR arrays. We demonstrate surface treatment via UV Ozone cleaning of such samples to allow introduction of analyte molecules (benzenethiol and cannabinol) for effective surface enhanced Raman scattering detection. This is the first demonstration of the SERS analysis of cannabinol. This approach demonstrates a cost-effective, high-yield and simple fabrication route to SERS sensors with application in the screening for the cannabinoids. Copyright © 2018. Published by Elsevier B.V.
Cuthbertson, Brian H; Campbell, Marion K; Stott, Stephen A; Elders, Andrew; Hernández, Rodolfo; Boyers, Dwayne; Norrie, John; Kinsella, John; Brittenden, Julie; Cook, Jonathan; Rae, Daniela; Cotton, Seonaidh C; Alcorn, David; Addison, Jennifer; Grant, Adrian
2011-01-01
Fluid strategies may impact on patient outcomes in major elective surgery. We aimed to study the effectiveness and cost-effectiveness of pre-operative fluid loading in high-risk surgical patients undergoing major elective surgery. This was a pragmatic, non-blinded, multi-centre, randomised, controlled trial. We sought to recruit 128 consecutive high-risk surgical patients undergoing major abdominal surgery. The patients underwent pre-operative fluid loading with 25 ml/kg of Ringer's solution in the six hours before surgery. The control group had no pre-operative fluid loading. The primary outcome was the number of hospital days after surgery with cost-effectiveness as a secondary outcome. A total of 111 patients were recruited within the study time frame in agreement with the funder. The median pre-operative fluid loading volume was 1,875 ml (IQR 1,375 to 2,025) in the fluid group compared to 0 (IQR 0 to 0) in controls with days in hospital after surgery 12.2 (SD 11.5) days compared to 17.4 (SD 20.0) and an adjusted mean difference of 5.5 days (median 2.2 days; 95% CI -0.44 to 11.44; P = 0.07). There was a reduction in adverse events in the fluid intervention group (P = 0.048) and no increase in fluid based complications. The intervention was less costly and more effective (adjusted average cost saving: £2,047; adjusted average gain in benefit: 0.0431 quality adjusted life year (QALY)) and has a high probability of being cost-effective. Pre-operative intravenous fluid loading leads to a non-significant reduction in hospital length of stay after high-risk major surgery and is likely to be cost-effective. Confirmatory work is required to determine whether these effects are reproducible, and to confirm whether this simple intervention could allow more cost-effective delivery of care. Prospective Clinical Trials, ISRCTN32188676.
2011-01-01
Introduction Fluid strategies may impact on patient outcomes in major elective surgery. We aimed to study the effectiveness and cost-effectiveness of pre-operative fluid loading in high-risk surgical patients undergoing major elective surgery. Methods This was a pragmatic, non-blinded, multi-centre, randomised, controlled trial. We sought to recruit 128 consecutive high-risk surgical patients undergoing major abdominal surgery. The patients underwent pre-operative fluid loading with 25 ml/kg of Ringer's solution in the six hours before surgery. The control group had no pre-operative fluid loading. The primary outcome was the number of hospital days after surgery with cost-effectiveness as a secondary outcome. Results A total of 111 patients were recruited within the study time frame in agreement with the funder. The median pre-operative fluid loading volume was 1,875 ml (IQR 1,375 to 2,025) in the fluid group compared to 0 (IQR 0 to 0) in controls with days in hospital after surgery 12.2 (SD 11.5) days compared to 17.4 (SD 20.0) and an adjusted mean difference of 5.5 days (median 2.2 days; 95% CI -0.44 to 11.44; P = 0.07). There was a reduction in adverse events in the fluid intervention group (P = 0.048) and no increase in fluid based complications. The intervention was less costly and more effective (adjusted average cost saving: £2,047; adjusted average gain in benefit: 0.0431 quality adjusted life year (QALY)) and has a high probability of being cost-effective. Conclusions Pre-operative intravenous fluid loading leads to a non-significant reduction in hospital length of stay after high-risk major surgery and is likely to be cost-effective. Confirmatory work is required to determine whether these effects are reproducible, and to confirm whether this simple intervention could allow more cost-effective delivery of care. Trial registration Prospective Clinical Trials, ISRCTN32188676 PMID:22177541
Flow-induced immobilization of glucose oxidase in nonionic micellar nanogels for glucose sensing.
Cardiel, Joshua J; Zhao, Ya; Tonggu, Lige; Wang, Liguo; Chung, Jae-Hyun; Shen, Amy Q
2014-10-21
A simple microfluidic platform was utilized to immobilize glucose oxidase (GOx) in a nonionic micellar scaffold. The immobilization of GOx was verified by using a combination of cryogenic electron microscopy (cryo-EM), scanning electron microscopy (SEM), and ultraviolet spectroscopy (UV) techniques. Chronoamperometric measurements were conducted on nanogel-GOx scaffolds under different glucose concentrations, exhibiting linear amperometric responses. Without impacting the lifetime and denaturation of GOx, the nonionic nanogel provides a favorable microenvironment for GOx in biological media. This flow-induced immobilization method in a nonionic nanogel host matrix opens up new pathways for designing a simple, fast, biocompatible, and cost-effective process to immobilize biomolecules that are averse to ionic environments.
Economic modeling of HIV treatments.
Simpson, Kit N
2010-05-01
To review the general literature on microeconomic modeling and key points that must be considered in the general assessment of economic modeling reports, discuss the evolution of HIV economic models and identify models that illustrate this development over time, as well as examples of current studies. Recommend improvements in HIV economic modeling. Recent economic modeling studies of HIV include examinations of scaling up antiretroviral (ARV) in South Africa, screening prior to use of abacavir, preexposure prophylaxis, early start of ARV in developing countries and cost-effectiveness comparisons of specific ARV drugs using data from clinical trials. These studies all used extensively published second-generation Markov models in their analyses. There have been attempts to simplify approaches to cost-effectiveness estimates by using simple decision trees or cost-effectiveness calculations with short-time horizons. However, these approaches leave out important cumulative economic effects that will not appear early in a treatment. Many economic modeling studies were identified in the 'gray' literature, but limited descriptions precluded an assessment of their adherence to modeling guidelines, and thus to the validity of their findings. There is a need for developing third-generation models to accommodate new knowledge about adherence, adverse effects, and viral resistance.
Kincaid, D Lawrence; Do, Mai Phuong
2006-01-01
Cost-effectiveness analysis is based on a simple formula. A dollar estimate of the total cost to conduct a program is divided by the number of people estimated to have been affected by it in terms of some intended outcome. The direct, total costs of most communication campaigns are usually available. Estimating the amount of effect that can be attributed to the communication alone, however is problematical in full-coverage, mass media campaigns where the randomized control group design is not feasible. Single-equation, multiple regression analysis controls for confounding variables but does not adequately address the issue of causal attribution. In this article, multivariate causal attribution (MCA) methods are applied to data from a sample survey of 1,516 married women in the Philippines to obtain a valid measure of the number of new adopters of modern contraceptives that can be causally attributed to a national mass media campaign and to calculate its cost-effectiveness. The MCA analysis uses structural equation modeling to test the causal pathways and to test for endogeneity, biprobit analysis to test for direct effects of the campaign and endogeneity, and propensity score matching to create a statistically equivalent, matched control group that approximates the results that would have been obtained from a randomized control group design. The MCA results support the conclusion that the observed, 6.4 percentage point increase in modern contraceptive use can be attributed to the national mass media campaign and to its indirect effects on attitudes toward contraceptives. This net increase represented 348,695 new adopters in the population of married women at a cost of U.S. $1.57 per new adopter.
SERS-based pesticide detection by using nanofinger sensors
NASA Astrophysics Data System (ADS)
Kim, Ansoon; Barcelo, Steven J.; Li, Zhiyong
2015-01-01
Simple, sensitive, and rapid detection of trace levels of extensively used and highly toxic pesticides are in urgent demand for public health. Surface-enhanced Raman scattering (SERS)-based sensor was designed to achieve ultrasensitive and simple pesticide sensing. We developed a portable sensor system composed of high performance and reliable gold nanofinger sensor strips and a custom-built portable Raman spectrometer. Compared to the general procedure and previously reported studies that are limited to laboratory settings, our analytical method is simple, sensitive, rapid, and cost-effective. Based on the SERS results, the chemical interaction of two pesticides, chlorpyrifos (CPF) and thiabendazole (TBZ), with gold nanofingers was studied to determine a fingerprint for each pesticide. The portable SERS-sensor system was successfully demonstrated to detect CPF and TBZ pesticides within 15 min with a detection limit of 35 ppt in drinking water and 7 ppb on apple skin, respectively.
Diego, Ariel de Lima; Stemberg Martins, de Vasconcelos; Dias, Leite José Alberto; Moreira, Pinto Dilamar; Beltrão, Teixeira Rogério; Coelho, de Léo Álvaro; de Lima, Silveira Leonardo; Krause, Gonçalves Romeu; Carvalho Krause, Gonçalves Marcelo; Carolina Leite, de Vasconcelos Ana; Dias Costa, Filho Carlos Frederico; Lana Lacerda, de Lima
2017-01-01
An anterior cruciate ligament (ACL) rupture is a frequent injury, with short and long-term consequences if left untreated. With a view to benefitting as many patients as possible and preventing future complications, we created a low-cost ligament reconstruction technique. The present article describes an anatomic ACL reconstruction technique. The technique involves single-band reconstruction, using flexors tendon graft, outside-in tunnel perforation, femoral fixation with metal interference screw and surgical staples (Agrafe) in the longitudinal position. We present a simple, easy-to-reproduce technique that, when executed on patients with good bone quality, primarily in the tibia, is effective and inexpensive, favoring its large scale application.
Diego, Ariel de Lima; Stemberg Martins, de Vasconcelos,; Dias, Leite, José Alberto; Moreira, Pinto, Dilamar; Beltrão, Teixeira, Rogério; Coelho, de Léo, Álvaro; de Lima, Silveira, Leonardo; Krause, Gonçalves, Romeu; Carvalho Krause, Gonçalves, Marcelo; Carolina Leite, de Vasconcelos, Ana; Dias Costa, Filho, Carlos Frederico; Lana Lacerda, de Lima,
2017-01-01
Background: An anterior cruciate ligament (ACL) rupture is a frequent injury, with short and long-term consequences if left untreated. With a view to benefitting as many patients as possible and preventing future complications, we created a low-cost ligament reconstruction technique. Method: The present article describes an anatomic ACL reconstruction technique. Results: The technique involves single-band reconstruction, using flexors tendon graft, outside-in tunnel perforation, femoral fixation with metal interference screw and surgical staples (Agrafe) in the longitudinal position. Conclusion: We present a simple, easy-to-reproduce technique that, when executed on patients with good bone quality, primarily in the tibia, is effective and inexpensive, favoring its large scale application. PMID:29290851
When enough is enough: The worth of monitoring data in aquifer remediation design
NASA Astrophysics Data System (ADS)
James, Bruce R.; Gorelick, Steven M.
1994-12-01
Given the high cost of data collection at groundwater contamination remediation sites, it is becoming increasingly important to make data collection as cost-effective as possible. A Bayesian data worth framework is developed in an attempt to carry out this task for remediation programs in which a groundwater contaminant plume must be located and then hydraulically contained. The framework is applied to a hypothetical contamination problem where uncertainty in plume location and extent are caused by uncertainty in source location, source loading time, and aquifer heterogeneity. The goal is to find the optimum number and the best locations for a sequence of observation wells that minimize the expected cost of remediation plus sampling. Simplifying assumptions include steady state heads, advective transport, simple retardation, and remediation costs as a linear function of discharge rate. In the case here, an average of six observation wells was needed. Results indicate that this optimum number was particularly sensitive to the mean hydraulic conductivity. The optimum number was also sensitive to the variance of the hydraulic conductivity, annual discount rate, operating cost, and sample unit cost. It was relatively insensitive to the correlation length of hydraulic conductivity. For the case here, points of greatest uncertainty in plume presence were on average poor candidates for sample locations, and randomly located samples were not cost-effective.
A Simple and Reliable Method of Design for Standalone Photovoltaic Systems
NASA Astrophysics Data System (ADS)
Srinivasarao, Mantri; Sudha, K. Rama; Bhanu, C. V. K.
2017-06-01
Standalone photovoltaic (SAPV) systems are seen as a promoting method of electrifying areas of developing world that lack power grid infrastructure. Proliferations of these systems require a design procedure that is simple, reliable and exhibit good performance over its life time. The proposed methodology uses simple empirical formulae and easily available parameters to design SAPV systems, that is, array size with energy storage. After arriving at the different array size (area), performance curves are obtained for optimal design of SAPV system with high amount of reliability in terms of autonomy at a specified value of loss of load probability (LOLP). Based on the array to load ratio (ALR) and levelized energy cost (LEC) through life cycle cost (LCC) analysis, it is shown that the proposed methodology gives better performance, requires simple data and is more reliable when compared with conventional design using monthly average daily load and insolation.
Gonçalves-Araujo, Rafael; Wiegmann, Sonja; Torrecilla, Elena; Bardaji, Raul; Röttgers, Rüdiger; Bracher, Astrid; Piera, Jaume
2017-01-01
The detection and prediction of changes in coastal ecosystems require a better understanding of the complex physical, chemical and biological interactions, which involves that observations should be performed continuously. For this reason, there is an increasing demand for small, simple and cost-effective in situ sensors to analyze complex coastal waters at a broad range of scales. In this context, this study seeks to explore the potential of beam attenuation spectra, c(λ), measured in situ with an advanced-technology optical transmissometer, for assessing temporal and spatial patterns in the complex estuarine waters of Alfacs Bay (NW Mediterranean) as a test site. In particular, the information contained in the spectral beam attenuation coefficient was assessed and linked with different biogeochemical variables. The attenuation at λ = 710 nm was used as a proxy for particle concentration, TSM, whereas a novel parameter was adopted as an optical indicator for chlorophyll a (Chl-a) concentration, based on the local maximum of c(λ) observed at the long-wavelength side of the red band Chl-a absorption peak. In addition, since coloured dissolved organic matter (CDOM) has an important influence on the beam attenuation spectral shape and complementary measurements of particle size distribution were available, the beam attenuation spectral slope was used to analyze the CDOM content. Results were successfully compared with optical and biogeochemical variables from laboratory analysis of collocated water samples, and statistically significant correlations were found between the attenuation proxies and the biogeochemical variables TSM, Chl-a and CDOM. This outcome depicted the potential of high-frequency beam attenuation measurements as a simple, continuous and cost-effective approach for rapid detection of changes and patterns in biogeochemical properties in complex coastal environments. PMID:28107539
Kruger, Jen; Pollard, Daniel; Basarir, Hasan; Thokala, Praveen; Cooke, Debbie; Clark, Marie; Bond, Rod; Heller, Simon; Brennan, Alan
2015-10-01
. Health economic modeling has paid limited attention to the effects that patients' psychological characteristics have on the effectiveness of treatments. This case study tests 1) the feasibility of incorporating psychological prediction models of treatment response within an economic model of type 1 diabetes, 2) the potential value of providing treatment to a subgroup of patients, and 3) the cost-effectiveness of providing treatment to a subgroup of responders defined using 5 different algorithms. . Multiple linear regressions were used to investigate relationships between patients' psychological characteristics and treatment effectiveness. Two psychological prediction models were integrated with a patient-level simulation model of type 1 diabetes. Expected value of individualized care analysis was undertaken. Five different algorithms were used to provide treatment to a subgroup of predicted responders. A cost-effectiveness analysis compared using the algorithms to providing treatment to all patients. . The psychological prediction models had low predictive power for treatment effectiveness. Expected value of individualized care results suggested that targeting education at responders could be of value. The cost-effectiveness analysis suggested, for all 5 algorithms, that providing structured education to a subgroup of predicted responders would not be cost-effective. . The psychological prediction models tested did not have sufficient predictive power to make targeting treatment cost-effective. The psychological prediction models are simple linear models of psychological behavior. Collection of data on additional covariates could potentially increase statistical power. . By collecting data on psychological variables before an intervention, we can construct predictive models of treatment response to interventions. These predictive models can be incorporated into health economic models to investigate more complex service delivery and reimbursement strategies. © The Author(s) 2015.
Extending cluster Lot Quality Assurance Sampling designs for surveillance programs
Hund, Lauren; Pagano, Marcello
2014-01-01
Lot quality assurance sampling (LQAS) has a long history of applications in industrial quality control. LQAS is frequently used for rapid surveillance in global health settings, with areas classified as poor or acceptable performance based on the binary classification of an indicator. Historically, LQAS surveys have relied on simple random samples from the population; however, implementing two-stage cluster designs for surveillance sampling is often more cost-effective than simple random sampling. By applying survey sampling results to the binary classification procedure, we develop a simple and flexible non-parametric procedure to incorporate clustering effects into the LQAS sample design to appropriately inflate the sample size, accommodating finite numbers of clusters in the population when relevant. We use this framework to then discuss principled selection of survey design parameters in longitudinal surveillance programs. We apply this framework to design surveys to detect rises in malnutrition prevalence in nutrition surveillance programs in Kenya and South Sudan, accounting for clustering within villages. By combining historical information with data from previous surveys, we design surveys to detect spikes in the childhood malnutrition rate. PMID:24633656
Extending cluster lot quality assurance sampling designs for surveillance programs.
Hund, Lauren; Pagano, Marcello
2014-07-20
Lot quality assurance sampling (LQAS) has a long history of applications in industrial quality control. LQAS is frequently used for rapid surveillance in global health settings, with areas classified as poor or acceptable performance on the basis of the binary classification of an indicator. Historically, LQAS surveys have relied on simple random samples from the population; however, implementing two-stage cluster designs for surveillance sampling is often more cost-effective than simple random sampling. By applying survey sampling results to the binary classification procedure, we develop a simple and flexible nonparametric procedure to incorporate clustering effects into the LQAS sample design to appropriately inflate the sample size, accommodating finite numbers of clusters in the population when relevant. We use this framework to then discuss principled selection of survey design parameters in longitudinal surveillance programs. We apply this framework to design surveys to detect rises in malnutrition prevalence in nutrition surveillance programs in Kenya and South Sudan, accounting for clustering within villages. By combining historical information with data from previous surveys, we design surveys to detect spikes in the childhood malnutrition rate. Copyright © 2014 John Wiley & Sons, Ltd.
Vinten, Andy; Sample, James; Ibiyemi, Adekunle; Abdul-Salam, Yakubu; Stutter, Marc
2017-05-15
The cost-effectiveness of six edge-of-field measures for mitigating diffuse pollution from sediment bound phosphorus (P) runoff from temperate arable farmland is analysed at catchment/field scales. These measures were: buffer strips, permanent grassland in the lowest 7% of arable fields, dry detention bunds, wetlands, and temporary barriers such as sediment fences. Baseline field P export was estimated using export coefficients (low risk crops) or a modified Universal Soil Loss Equation (high risk crops). The impact of measures was estimated using simple equations. Costs were estimated from gross margin losses or local data on grants. We used a net cost:benefit (NCB) factor to normalise the costs and impacts of each measure over time. Costs minimisation for target impact was done using PuLP, a linear programming module for Python, across 1634 riparian and non-riparian fields in the Lunan Water, a mixed arable catchment in Eastern Scotland. With all measures in place, average cost-effectiveness increases from £9 to £48/kg P as target P mitigation increases from 500 to 2500kg P across the catchment. Costs increase significantly when the measures available are restricted only to those currently eligible for government grants (buffers, bunds and wetlands). The assumed orientation of the average field slope makes a strong difference to the potential for storage of water by bunds and overall cost-effectiveness, but the non-funded measures can substitute for the extra expense incurred by bunds, where the slope orientation is not suitable. Economic discounting over time of impacts and costs of measures favours those measures, such as sediment fences, which are strongly targeted both spatially and temporally. This tool could be a useful guide for dialogue with land users about the potential fields to target for mitigation to achieve catchment targets. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Nguyen, D Duc; Ngo, H Hao; Guo, W; Nguyen, T Thanh; Chang, Soon W; Jang, A; Yoon, Yong S
2016-09-01
This paper evaluated a novel pilot scale electrocoagulation (EC) system for improving total phosphorus (TP) removal from municipal wastewater. This EC system was operated in continuous and batch operating mode under differing conditions (e.g. flow rate, initial concentration, electrolysis time, conductivity, voltage) to evaluate correlative phosphorus and electrical energy consumption. The results demonstrated that the EC system could effectively remove phosphorus to meet current stringent discharge standards of less than 0.2mg/L within 2 to 5min. This target was achieved in all ranges of initial TP concentrations studied. It was also found that an increase in conductivity of solution, voltages, or electrolysis time, correlated with improved TP removal efficiency and reduced specific energy consumption. Based on these results, some key economic considerations, such as operating costs, cost-effectiveness, product manufacturing feasibility, facility design and retrofitting, and program implementation are also discussed. This EC process can conclusively be highly efficient in a relatively simple, easily managed, and cost-effective for wastewater treatment system. Copyright © 2016 Elsevier B.V. All rights reserved.
Petrinco, Michele; Pagano, Eva; Desideri, Alessandro; Bigi, Riccardo; Ghidina, Marco; Ferrando, Alberto; Cortigiani, Lauro; Merletti, Franco; Gregori, Dario
2009-01-01
Several methodological problems arise when health outcomes and resource utilization are collected at different sites. To avoid misleading conclusions in multi-center economic evaluations the center effect needs to be taken into adequate consideration. The aim of this article is to compare several models, which make use of a different amount of information about the enrolling center. To model the association of total medical costs with the levels of two sets of covariates, one at patient and one at center level, we considered four statistical models, based on the Gamma model in the class of the Generalized Linear Models with a log link, which use different amount of information on the enrolling centers. Models were applied to Cost of Strategies after Myocardial Infarction data, an international randomized trial on costs of uncomplicated acute myocardial infarction (AMI). The simple center effect adjustment based on a single random effect results in a more conservative estimation of the parameters as compared with approaches which make use of deeper information on the centers characteristics. This study shows, with reference to a real multicenter trial, that center information cannot be neglected and should be collected and inserted in the analysis, better in combination with one or more random effect, taking into account in this way also the heterogeneity among centers because of unobserved centers characteristics.
2014-01-01
Background Cost-effectiveness analyses (CEAs) that use patient-specific data from a randomized controlled trial (RCT) are popular, yet such CEAs are criticized because they neglect to incorporate evidence external to the trial. A popular method for quantifying uncertainty in a RCT-based CEA is the bootstrap. The objective of the present study was to further expand the bootstrap method of RCT-based CEA for the incorporation of external evidence. Methods We utilize the Bayesian interpretation of the bootstrap and derive the distribution for the cost and effectiveness outcomes after observing the current RCT data and the external evidence. We propose simple modifications of the bootstrap for sampling from such posterior distributions. Results In a proof-of-concept case study, we use data from a clinical trial and incorporate external evidence on the effect size of treatments to illustrate the method in action. Compared to the parametric models of evidence synthesis, the proposed approach requires fewer distributional assumptions, does not require explicit modeling of the relation between external evidence and outcomes of interest, and is generally easier to implement. A drawback of this approach is potential computational inefficiency compared to the parametric Bayesian methods. Conclusions The bootstrap method of RCT-based CEA can be extended to incorporate external evidence, while preserving its appealing features such as no requirement for parametric modeling of cost and effectiveness outcomes. PMID:24888356
Sadatsafavi, Mohsen; Marra, Carlo; Aaron, Shawn; Bryan, Stirling
2014-06-03
Cost-effectiveness analyses (CEAs) that use patient-specific data from a randomized controlled trial (RCT) are popular, yet such CEAs are criticized because they neglect to incorporate evidence external to the trial. A popular method for quantifying uncertainty in a RCT-based CEA is the bootstrap. The objective of the present study was to further expand the bootstrap method of RCT-based CEA for the incorporation of external evidence. We utilize the Bayesian interpretation of the bootstrap and derive the distribution for the cost and effectiveness outcomes after observing the current RCT data and the external evidence. We propose simple modifications of the bootstrap for sampling from such posterior distributions. In a proof-of-concept case study, we use data from a clinical trial and incorporate external evidence on the effect size of treatments to illustrate the method in action. Compared to the parametric models of evidence synthesis, the proposed approach requires fewer distributional assumptions, does not require explicit modeling of the relation between external evidence and outcomes of interest, and is generally easier to implement. A drawback of this approach is potential computational inefficiency compared to the parametric Bayesian methods. The bootstrap method of RCT-based CEA can be extended to incorporate external evidence, while preserving its appealing features such as no requirement for parametric modeling of cost and effectiveness outcomes.
A novel cost-effective approach to post-vasectomy semen analysis.
Senanayake, Eshan; Pacey, Allan A; Maddireddy, Vinod; Shariff, Umar; Hastie, Ken; Rosario, Derek J
2011-05-01
• To examine compliance, clearance rates and cost-effectiveness of a novel approach to managing men following vasectomy based on the testing of sperm viability. • Between January 2003 and March 2005, 832 men undergoing vasectomy were followed prospectively for a minimum of 12 months. • Post-vasectomy semen analysis (PVSA) was carried out at 16 weeks with repeat at 20 weeks only if sperm were detected on initial PVSA i.e. a single clear PVSA on simple microscopy was deemed sufficient for declaring vasectomy successful. • In men with persistent non-motile sperm (PNMS) in the second specimen, comprehensive analysis of number and viability of sperm using a fluorescent probe was carried out on a fresh semen specimen taken in accordance with British Andrology Society (BAS) guidelines. • Overall compliance with the PVSA protocol was 81.3% (95% CI 78.5 to 83.8). No sperm were seen in 540 (78.8%) and 70 (10.3%) at the initial and 2(nd) PVSA respectively. • Persistent spermatozoa at 20 weeks were present in 66 (9.8%, 7.8 to 12.2) cases with 58 (8.6%, 6.7 to 11.0) having PNMS and 8 (1.2%, 0.6 to 2.3) having motile sperm. • Fluorescent viability testing in 53 of the 58 with PNMS showed viable sperm in 2 (3.8%, 1.0 to 12.8). The failure rate of vasectomy defined by PVSA (8 with motile sperm on 2(nd) PVSA and 2 with viable non-motile sperm on fluorescent testing) was 1.2% (0.7 to 2.2). • Average cost per vasectomy of PVSA using this protocol was £10.77 (US$ 16.67) compared with a minimum likely average cost using BAS guidelines of £18.10 (US$ 28). • Demonstrating absence of sperm on simple light microscopy in a single specimen of semen at 16 or 20 weeks post-vasectomy and reserving comprehensive testing of sperm viability for only the higher risk group with PNMS improves compliance and represents a cost-effective strategy for declaring surgical success. This reduces the costs of PVSA by least 40% compared with adherence with BAS guidelines without compromising success in determining outcome after vasectomy. © 2010 THE AUTHORS. BJU INTERNATIONAL © 2010 BJU INTERNATIONAL.
Accounting for the drug life cycle and future drug prices in cost-effectiveness analysis.
Hoyle, Martin
2011-01-01
Economic evaluations of health technologies typically assume constant real drug prices and model only the cohort of patients currently eligible for treatment. It has recently been suggested that, in the UK, we should assume that real drug prices decrease at 4% per annum and, in New Zealand, that real drug prices decrease at 2% per annum and at patent expiry the drug price falls. It has also recently been suggested that we should model multiple future incident cohorts. In this article, the cost effectiveness of drugs is modelled based on these ideas. Algebraic expressions are developed to capture all costs and benefits over the entire life cycle of a new drug. The lifetime of a new drug in the UK, a key model parameter, is estimated as 33 years, based on the historical lifetime of drugs in England over the last 27 years. Under the proposed methodology, cost effectiveness is calculated for seven new drugs recently appraised in the UK. Cost effectiveness as assessed in the future is also estimated. Whilst the article is framed in mathematics, the findings and recommendations are also explained in non-mathematical language. The 'life-cycle correction factor' is introduced, which is used to convert estimates of cost effectiveness as traditionally calculated into estimates under the proposed methodology. Under the proposed methodology, all seven drugs appear far more cost effective in the UK than published. For example, the incremental cost-effectiveness ratio decreases by 46%, from £61, 900 to £33, 500 per QALY, for cinacalcet versus best supportive care for end-stage renal disease, and by 45%, from £31,100 to £17,000 per QALY, for imatinib versus interferon-α for chronic myeloid leukaemia. Assuming real drug prices decrease over time, the chance that a drug is publicly funded increases over time, and is greater when modelling multiple cohorts than with a single cohort. Using the methodology (compared with traditional methodology) all drugs in the UK and New Zealand are predicted to be more cost effective. It is suggested that the willingness-to-pay threshold should be reduced in the UK and New Zealand. The ranking of cost effectiveness will change with drugs assessed as relatively more cost effective and medical devices and surgical procedures relatively less cost effective than previously thought. The methodology is very simple to implement. It is suggested that the model should be parameterized for other countries.
Software Development Cost Estimation Executive Summary
NASA Technical Reports Server (NTRS)
Hihn, Jairus M.; Menzies, Tim
2006-01-01
Identify simple fully validated cost models that provide estimation uncertainty with cost estimate. Based on COCOMO variable set. Use machine learning techniques to determine: a) Minimum number of cost drivers required for NASA domain based cost models; b) Minimum number of data records required and c) Estimation Uncertainty. Build a repository of software cost estimation information. Coordinating tool development and data collection with: a) Tasks funded by PA&E Cost Analysis; b) IV&V Effort Estimation Task and c) NASA SEPG activities.
A cost effective method of meeting emission requirements from a 50 MMscfd glycol dehydrator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gearhart, L.E.
1998-12-31
The removal of volatile organic compounds (VOC) and benzene, toluene, ethylbenzene, xylene (BTEX) from glycol dehydration systems does not require costly equipment or elaborate controls. This paper will describe the design and installation of a 10 equivalent try glycol dehydration unit for field gas dehydration. The absorber design minimizes the absorption of VOC and BTEX by requiring 1.0 to 1.5 gallons of glycol per pound of water removed. Glycol unit VOC emissions are effectively controlled without installing vent gas condensers which require disposal of the waste condensate. The emission control system on this unit is simple to operate, meets emissionmore » standards and the dehydrator design achieves pipeline sales gas specifications at a reasonable cost. The system reduces the VOC and BTEX by adding a stripper on the glycol going to the reboiler. A 50 MMscfd dehydrator was installed in December 1995 and the results of an emission test done in April 1997 are presented in this paper.« less
Meloni, Gabriel N; Bertotti, Mauro
2017-01-01
A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM) sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder.
Bertotti, Mauro
2017-01-01
A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM) sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder. PMID:28753638
Breilh, Jaime; Pagliccia, Nino; Yassi, Annalee
2012-01-01
Chronic pesticide poisoning is difficult to detect. We sought to develop a low-cost test battery for settings such as Ecuador's floriculture industry. First we had to develop a case definition; as with all occupational diseases a case had to have both sufficient effective dose and associated health effects. For the former, using canonical discriminant analysis, we found that adding measures of protection and overall environmental stressors to occupational category and duration of exposure was useful. For the latter, factor analysis suggested three distinct manifestations of pesticide poisoning. We then determined sensitivity and specificity of various combinations of symptoms and simple neurotoxicity tests from the Pentox questionnaire, and found that doing so increased sensitivity and specificity compared to use of acethylcholinesterase alone--the current screening standard. While sensitivity and specificity varied with different case definitions, our results support the development of a low-cost test battery for screening in such settings.
Lin, Da; Hong, Ping; Zhang, Siheng; Xu, Weize; Jamal, Muhammad; Yan, Keji; Lei, Yingying; Li, Liang; Ruan, Yijun; Fu, Zhen F; Li, Guoliang; Cao, Gang
2018-05-01
Chromosome conformation capture (3C) technologies can be used to investigate 3D genomic structures. However, high background noise, high costs, and a lack of straightforward noise evaluation in current methods impede the advancement of 3D genomic research. Here we developed a simple digestion-ligation-only Hi-C (DLO Hi-C) technology to explore the 3D landscape of the genome. This method requires only two rounds of digestion and ligation, without the need for biotin labeling and pulldown. Non-ligated DNA was efficiently removed in a cost-effective step by purifying specific linker-ligated DNA fragments. Notably, random ligation could be quickly evaluated in an early quality-control step before sequencing. Moreover, an in situ version of DLO Hi-C using a four-cutter restriction enzyme has been developed. We applied DLO Hi-C to delineate the genomic architecture of THP-1 and K562 cells and uncovered chromosomal translocations. This technology may facilitate investigation of genomic organization, gene regulation, and (meta)genome assembly.
Dewa, Carolyn S; Hoch, Jeffrey S
2014-06-01
This article estimates the net benefit for a company incorporating a collaborative care model into its return-to-work program for workers on short-term disability related to a mental disorder. Employing a simple decision model, the net benefit and uncertainty were explored. The breakeven point occurs when the average short-term disability episode is reduced by at least 7 days. In addition, 85% of the time, benefits could outweigh costs. Model results and sensitivity analyses indicate that organizational benefits can be greater than the costs of incorporating a collaborative care model into a return-to-work program for workers on short-term disability related to a mental disorder. The results also demonstrate how the probability of a program's effectiveness and the magnitude of its effectiveness are key factors that determine whether the benefits of a program outweigh its costs.
Low-cost oblique illumination: an image quality assessment.
Ruiz-Santaquiteria, Jesus; Espinosa-Aranda, Jose Luis; Deniz, Oscar; Sanchez, Carlos; Borrego-Ramos, Maria; Blanco, Saul; Cristobal, Gabriel; Bueno, Gloria
2018-01-01
We study the effectiveness of several low-cost oblique illumination filters to improve overall image quality, in comparison with standard bright field imaging. For this purpose, a dataset composed of 3360 diatom images belonging to 21 taxa was acquired. Subjective and objective image quality assessments were done. The subjective evaluation was performed by a group of diatom experts by psychophysical test where resolution, focus, and contrast were assessed. Moreover, some objective nonreference image quality metrics were applied to the same image dataset to complete the study, together with the calculation of several texture features to analyze the effect of these filters in terms of textural properties. Both image quality evaluation methods, subjective and objective, showed better results for images acquired using these illumination filters in comparison with the no filtered image. These promising results confirm that this kind of illumination filters can be a practical way to improve the image quality, thanks to the simple and low cost of the design and manufacturing process. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
A cost-based comparison of quarantine strategies for new emerging diseases.
Mubayi, Anuj; Zaleta, Christopher Kribs; Martcheva, Maia; Castillo-Chávez, Carlos
2010-07-01
A classical epidemiological framework is used to provide a preliminary cost analysis of the effects of quarantine and isolation on the dynamics of infectious diseases for which no treatment or immediate diagnosis tools are available. Within this framework we consider the cost incurred from the implementation of three types of dynamic control strategies. Taking the context of the 2003 SARS outbreak in Hong Kong as an example, we use a simple cost function to compare the total cost of each mixed (quarantine and isolation) control strategy from a public health resource allocation perspective. The goal is to extend existing epi-economics methodology by developing a theoretical framework of dynamic quarantine strategies aimed at emerging diseases, by drawing upon the large body of literature on the dynamics of infectious diseases. We find that the total cost decreases with increases in the quarantine rates past a critical value, regardless of the resource allocation strategy. In the case of a manageable outbreak resources must be used early to achieve the best results whereas in case of an unmanageable outbreak, a constant-effort strategy seems the best among our limited plausible sets.
24 CFR 200.97 - Adjustments resulting from cost certification.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 24 Housing and Urban Development 2 2011-04-01 2011-04-01 false Adjustments resulting from cost certification. 200.97 Section 200.97 Housing and Urban Development Regulations Relating to Housing and Urban... Adjustments resulting from cost certification. (a) Fee simple site. Upon receipt of the mortgagor's...
24 CFR 200.97 - Adjustments resulting from cost certification.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 24 Housing and Urban Development 2 2014-04-01 2014-04-01 false Adjustments resulting from cost certification. 200.97 Section 200.97 Housing and Urban Development Regulations Relating to Housing and Urban... Adjustments resulting from cost certification. (a) Fee simple site. Upon receipt of the mortgagor's...
24 CFR 200.97 - Adjustments resulting from cost certification.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 24 Housing and Urban Development 2 2012-04-01 2012-04-01 false Adjustments resulting from cost certification. 200.97 Section 200.97 Housing and Urban Development Regulations Relating to Housing and Urban... Adjustments resulting from cost certification. (a) Fee simple site. Upon receipt of the mortgagor's...
24 CFR 200.97 - Adjustments resulting from cost certification.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 24 Housing and Urban Development 2 2013-04-01 2013-04-01 false Adjustments resulting from cost certification. 200.97 Section 200.97 Housing and Urban Development Regulations Relating to Housing and Urban... Adjustments resulting from cost certification. (a) Fee simple site. Upon receipt of the mortgagor's...
49 CFR 92.35 - Interest, penalties and administrative costs.
Code of Federal Regulations, 2010 CFR
2010-10-01
... accrue until payment is received. Interest shall be calculated only on the principal of the debt (simple... 49 Transportation 1 2010-10-01 2010-10-01 false Interest, penalties and administrative costs. 92... UNITED STATES BY SALARY OFFSET § 92.35 Interest, penalties and administrative costs. (a) Where a DOT...
Simplified Life-Cycle Cost Estimation
NASA Technical Reports Server (NTRS)
Remer, D. S.; Lorden, G.; Eisenberger, I.
1983-01-01
Simple method for life-cycle cost (LCC) estimation avoids pitfalls inherent in formulations requiring separate estimates of inflation and interest rates. Method depends for validity observation that interest and inflation rates closely track each other.
Brar, Harinder; Hogen, Liat; Covens, Al
2017-05-15
The objective of this study was to determine the cost-effectiveness of radical hysterectomy (RH) and sentinel lymph node biopsy (SLNB) for the management of early-stage cervical cancer (stage IA2-IB1). A simple decision tree model was developed to follow a simulated cohort of patients with early-stage cervical cancer treated with RH and 1 of 3 lymph node assessment strategies: systematic pelvic lymph node dissection (PLND), SLNB using technetium 99 (Tc99) and blue dye, and SLNB using Tc99 only. SLNB using indocyanine green (ICG) was used as an exploratory strategy. Relevant studies were identified to extract the probability data and utility parameters and to estimate quality-adjusted life-years (QALYs) and absolute life-years (ALYs). Only direct medical costs were modeled, and the time horizon for the study was 5 years. SLNB using Tc99 and blue dye cost $21,089 and yielded 4.54 QALYs and 4.90 ALYs. PLND cost $22,353 and yielded 4.47 QALYs and 4.91 ALYs. SLNB using blue dye and Tc99 was the most cost-effective strategy when ALYs were considered with an incremental cost-effectiveness ratio (ICER) of $144,531. When QALYs were considered, the SLNB technique using Tc99 and blue dye dominated all other strategies. SLNB using ICG cost $20,624 and yielded 4.90 ALYs and 4.54 QALYs. It was clinically superior to and less expensive than all other strategies when QALYs were the outcome of interest and had an ICER of $221,171 per ALY in comparison with RH plus PLND. SLNB using Tc99 and blue dye with ultrastaging is considered the most cost-effective strategy with respect to 5-year progression-free survival and morbidity-free survival. Although it was included only as an exploratory strategy in this study, SLNB with ICG has the potential to be the most cost-effective strategy. Cancer 2017;123:1751-1759. © 2017 American Cancer Society. © 2017 American Cancer Society.
McLeod, Melissa; Blakely, Tony; Kvizhinadze, Giorgi; Harris, Ricci
2014-01-01
A critical first step toward incorporating equity into cost-effectiveness analyses is to appropriately model interventions by population subgroups. In this paper we use a standardized treatment intervention to examine the impact of using ethnic-specific (Māori and non-Māori) data in cost-utility analyses for three cancers. We estimate gains in health-adjusted life years (HALYs) for a simple intervention (20% reduction in excess cancer mortality) for lung, female breast, and colon cancers, using Markov modeling. Base models include ethnic-specific cancer incidence with other parameters either turned off or set to non-Māori levels for both groups. Subsequent models add ethnic-specific cancer survival, morbidity, and life expectancy. Costs include intervention and downstream health system costs. For the three cancers, including existing inequalities in background parameters (population mortality and comorbidities) for Māori attributes less value to a year of life saved compared to non-Māori and lowers the relative health gains for Māori. In contrast, ethnic inequalities in cancer parameters have less predictable effects. Despite Māori having higher excess mortality from all three cancers, modeled health gains for Māori were less from the lung cancer intervention than for non-Māori but higher for the breast and colon interventions. Cost-effectiveness modeling is a useful tool in the prioritization of health services. But there are important (and sometimes counterintuitive) implications of including ethnic-specific background and disease parameters. In order to avoid perpetuating existing ethnic inequalities in health, such analyses should be undertaken with care.
2014-01-01
Background A critical first step toward incorporating equity into cost-effectiveness analyses is to appropriately model interventions by population subgroups. In this paper we use a standardized treatment intervention to examine the impact of using ethnic-specific (Māori and non-Māori) data in cost-utility analyses for three cancers. Methods We estimate gains in health-adjusted life years (HALYs) for a simple intervention (20% reduction in excess cancer mortality) for lung, female breast, and colon cancers, using Markov modeling. Base models include ethnic-specific cancer incidence with other parameters either turned off or set to non-Māori levels for both groups. Subsequent models add ethnic-specific cancer survival, morbidity, and life expectancy. Costs include intervention and downstream health system costs. Results For the three cancers, including existing inequalities in background parameters (population mortality and comorbidities) for Māori attributes less value to a year of life saved compared to non-Māori and lowers the relative health gains for Māori. In contrast, ethnic inequalities in cancer parameters have less predictable effects. Despite Māori having higher excess mortality from all three cancers, modeled health gains for Māori were less from the lung cancer intervention than for non-Māori but higher for the breast and colon interventions. Conclusions Cost-effectiveness modeling is a useful tool in the prioritization of health services. But there are important (and sometimes counterintuitive) implications of including ethnic-specific background and disease parameters. In order to avoid perpetuating existing ethnic inequalities in health, such analyses should be undertaken with care. PMID:24910540
Cost effectiveness of drug eluting coronary artery stenting in a UK setting: cost-utility study.
Bagust, A; Grayson, A D; Palmer, N D; Perry, R A; Walley, T
2006-01-01
To assess the cost effectiveness of drug eluting stents (DES) compared with conventional stents for treatment of symptomatic coronary artery disease in the UK. Cost-utility analysis of audit based patient subgroups by means of a simple economic model. Tertiary care. 12 month audit data for 2884 patients receiving percutaneous coronary intervention with stenting at the Cardiothoracic Centre Liverpool between January 2000 and December 2002. Risk of repeat revascularisation within 12 months of index procedure and reduction in risk from use of DES. Economic modelling was used to estimate the cost-utility ratio and threshold price premium. Four factors were identified for patients undergoing elective surgery (n = 1951) and two for non-elective surgery (n = 933) to predict risk of repeat revascularisation within 12 months. Most patients fell within the subgroup with lowest risk (57% of the elective surgery group with 5.6% risk and 91% of the non-elective surgery group with 9.9% risk). Modelled cost-utility ratios were acceptable for only one group of high risk patients undergoing non-elective surgery (only one patient in audit data). Restricting the number of DES for each patient improved results marginally: 4% of stents could then be drug eluting on economic grounds. The threshold price premium justifying 90% substitution of conventional stents was estimated to be 112 pound sterling (212 USD, 162 pound sterling) (sirolimus stents) or 89 pound sterling (167 USD, 130 pound sterling) (paclitaxel stents). At current UK prices, DES are not cost effective compared with conventional stents except for a small minority of patients. Although the technology is clearly effective, general substitution is not justified unless the price premium falls substantially.
Economic Evaluation of a Hybrid Desalination System Combining Forward and Reverse Osmosis
Choi, Yongjun; Cho, Hyeongrak; Shin, Yonghyun; Jang, Yongsun; Lee, Sangho
2015-01-01
This study seeks to evaluate the performance and economic feasibility of the forward osmosis (FO)–reverse osmosis (RO) hybrid process; to propose a guideline by which this hybrid process might be more price-competitive in the field. A solution-diffusion model modified with film theory was applied to analyze the effects of concentration polarization, water, and salt transport coefficient on flux, recovery, seawater concentration, and treated wastewater of the FO process of an FO-RO hybrid system. A simple cost model was applied to analyze the effects of flux; recovery of the FO process; energy; and membrane cost on the FO-RO hybrid process. The simulation results showed that the water transport coefficient and internal concentration polarization resistance are very important factors that affect performance in the FO process; however; the effect of the salt transport coefficient does not seem to be large. It was also found that the flux and recovery of the FO process, the FO membrane, and the electricity cost are very important factors that influence the water cost of an FO-RO hybrid system. This hybrid system can be price-competitive with RO systems when its recovery rate is very high, the flux and the membrane cost of the FO are similar to those of the RO, and the electricity cost is expensive. The most important thing in commercializing the FO process is enhancing performance (e.g.; flux and the recovery of FO membranes). PMID:26729176
NASA Astrophysics Data System (ADS)
Jeon, Kiseok; Jee, Hongsub; Lim, Sangwoo; Park, Min Joon; Jeong, Chaehwan
2018-03-01
Effective incident light should be controlled for improving the current density of solar cells by employing nano- and micro-structures on silicon surface. The elastomeric stamp process, which is more cost effective and simpler than conventional photolithography, was proposed for the fabrication of nano- and micro-structures. Polydimethylsiloxane (PDMS) was poured on a mother pattern with a diameter of 6 μm and a spacing of 2 μm; then, curing was performed to create a PDMS mold. The regular micropattern was stamped on a low-viscosity resin-coated silicon surface, followed by the simple reactive ion etching process. Nano-structures were formed using the Ag-based electroless etching process. As etching time was increased to 6 min, reflectance decreased to 4.53% and current density improved from 22.35 to 34.72 mA/cm2.
Costs of postabortion care in public sector health facilities in Malawi: a cross-sectional survey.
Benson, Janie; Gebreselassie, Hailemichael; Mañibo, Maribel Amor; Raisanen, Keris; Johnston, Heidi Bart; Mhango, Chisale; Levandowski, Brooke A
2015-12-17
Health systems could obtain substantial cost savings by providing safe abortion care rather than providing expensive treatment for complications of unsafely performed abortions. This study estimates current health system costs of treating unsafe abortion complications and compares these findings with newly-projected costs for providing safe abortion in Malawi. We conducted in-depth surveys of medications, supplies, and time spent by clinical personnel dedicated to postabortion care (PAC) for three treatment categories (simple, severe non-surgical, and severe surgical complications) and three uterine evacuation (UE) procedure types (manual vacuum aspiration (MVA), dilation and curettage (D&C) and misoprostol-alone) at 15 purposively-selected public health facilities. Per-case treatment costs were calculated and applied to national, annual PAC caseload data. The median cost per D&C case ($63) was 29% higher than MVA treatment ($49). Costs to treat severe non-surgical complications ($63) were almost five times higher than those of a simple PAC case ($13). Severe surgical complications were especially costly to treat at $128. PAC treatment in public facilities cost an estimated $314,000 annually. Transition to safe, legal abortion would yield an estimated cost reduction of 20%-30%. The method of UE and severity of complications have a large impact on overall costs. With a liberalized abortion law and implementation of induced abortion services with WHO-recommended UE methods, current PAC costs to the health system could markedly decrease.
A Simple Metallothionein-Based Biosensor for Enhanced Detection of Arsenic and Mercury
Irvine, Gordon W.; Tan, Swee Ngin; Stillman, Martin J.
2017-01-01
Metallothioneins (MTs) are a family of cysteine-rich proteins whose biological roles include the regulation of essential metal ions and protection against the harmful effects of toxic metals. Due to its high affinity for many toxic, soft metals, recombinant human MT isoform 1a was incorporated into an electrochemical-based biosensor for the detection of As3+ and Hg2+. A simple design was chosen to maximize its potential in environmental monitoring and MT was physically adsorbed onto paper discs placed on screen-printed carbon electrodes (SPCEs). This system was tested with concentrations of arsenic and mercury typical of contaminated water sources ranging from 5 to 1000 ppb. The analytical performance of the MT-adsorbed paper discs on SPCEs demonstrated a greater than three-fold signal enhancement and a lower detection limit compared to blank SPCEs, 13 ppb for As3+ and 45 ppb for Hg2+. While not being as low as some of the recommended drinking water limits, the sensitivity of the simple MT-biosensor would be potentially useful in monitoring of areas of concern with a known contamination problem. This paper describes the ability of the metal binding protein metallothionein to enhance the effectiveness of a simple, low-cost electrochemical sensor. PMID:28335390
Automated external defibrillators in schools?
Cornelis, Charlotte; Calle, Paul; Mpotos, Nicolas; Monsieurs, Koenraad
2015-06-01
Automated external defibrillators (AEDs) placed in public locations can save lives of cardiac arrest victims. In this paper, we try to estimate the cost-effectiveness of AED placement in Belgian schools. This would allow school policy makers to make an evidence-based decision about an on-site AED project. We developed a simple mathematical model containing literature data on the incidence of cardiac arrest with a shockable rhythm; the feasibility and effectiveness of defibrillation by on-site AEDs and the survival benefit. This was coupled to a rough estimation of the minimal costs to initiate an AED project. According to the model described above, AED projects in all Belgian schools may save 5 patients annually. A rough estimate of the minimal costs to initiate an AED project is 660 EUR per year. As there are about 6000 schools in Belgium, a national AED project in all schools would imply an annual cost of at least 3960 000 EUR, resulting in 5 lives saved. As our literature survey shows that AED use in schools is feasible and effective, the placement of these devices in all Belgian schools is undoubtedly to be considered. The major counter-arguments are the very low incidence and the high costs to set up a school-based AED programme. Our review may fuel the discussion about Whether or not school-based AED projects represent good value for money and should be preferred above other health care interventions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dhanavel, S.; Nivethaa, E. A. K.; Esther, G.
Chitosan supported Palladium nanoparticles were synthesized by a simple cost effective chemical reduction method using NaBH{sub 4}. The prepared nanocomposite was characterized by X-Ray diffraction analysis, FESEM and Energy dispersive spectroscopy analysis of X-rays (EDAX). The catalytic performance of the nanocomposite was evaluated on the reduction of 2-Nitrophenol to the 2-Amino phenol with rate constant 1.08 × 10{sup −3} S{sup −1} by NaBH{sub 4} using Spectrophotometer.
Lords of the Silk Route: Violent Non-State Actors in Central Asia
2002-05-01
communications, internet connectivity, and the like; however, more traditional activities, such as simple cross-border smuggling, remain popular in the...Uzbekistan. It is a government production intended to sustain popular support for an on-going conflict with the Islamic Movement of Uzbekistan (IMU...valuable, cost-effective research to meet the needs of our sponsors. We appreciate your continued interest in INSS and our research products
Flexible Dye-Sensitized Solar Cell Based on Vertical ZnO Nanowire Arrays
2011-01-01
Flexible dye-sensitized solar cells are fabricated using vertically aligned ZnO nanowire arrays that are transferred onto ITO-coated poly(ethylene terephthalate) substrates using a simple peel-off process. The solar cells demonstrate an energy conversion efficiency of 0.44% with good bending tolerance. This technique paves a new route for building large-scale cost-effective flexible photovoltaic and optoelectronic devices. PMID:27502660
A simple and robust vector-based shRNA expression system used for RNA interference.
Wang, Xue-jun; Li, Ying; Huang, Hai; Zhang, Xiu-juan; Xie, Pei-wen; Hu, Wei; Li, Dan-dan; Wang, Sheng-qi
2013-01-01
RNA interference (RNAi) mediated by small interfering RNAs (siRNAs) or short hairpin RNAs (shRNAs) has become a powerful genetic tool for conducting functional studies. Previously, vector-based shRNA-expression strategies capable of inducing RNAi in viable cells have been developed, however, these vector systems have some disadvantages, either because they were error-prone or cost prohibitive. In this report we described the development of a simple, robust shRNA expression system utilizing 1 long oligonucleotide or 2 short oligonucleotides for half the cost of conventional shRNA construction methods and with a >95% cloning success rate. The shRNA loop sequence and stem structure were also compared and carefully selected for better RNAi efficiency. Furthermore, an easier strategy was developed based on isocaudomers which permit rapid combination of the most efficient promoter-shRNA cassettes. Finally, using this method, the conservative target sites for hepatitis B virus (HBV) knockdown were systemically screened and HBV antigen expression shown to be successfully suppressed in the presence of connected multiple shRNAs both in vitro and in vivo. This novel design describes an inexpensive and effective way to clone and express single or multiple shRNAs from the same vector with the capacity for potent and effective silencing of target genes.
Plasmonic SERS nanochips and nanoprobes for medical diagnostics and bio-energy applications
NASA Astrophysics Data System (ADS)
Ngo, Hoan T.; Wang, Hsin-Neng; Crawford, Bridget M.; Fales, Andrew M.; Vo-Dinh, Tuan
2017-02-01
The development of rapid, easy-to-use, cost-effective, high accuracy, and high sensitive DNA detection methods for molecular diagnostics has been receiving increasing interest. Over the last five years, our laboratory has developed several chip-based DNA detection techniques including the molecular sentinel-on-chip (MSC), the multiplex MSC, and the inverse molecular sentinel-on-chip (iMS-on-Chip). In these techniques, plasmonic surface-enhanced Raman scattering (SERS) Nanowave chips were functionalized with DNA probes for single-step DNA detection. Sensing mechanisms were based on hybridization of target sequences and DNA probes, resulting in a distance change between SERS reporters and the Nanowave chip's gold surface. This distance change resulted in change in SERS intensity, thus indicating the presence and capture of the target sequences. Our techniques were single-step DNA detection techniques. Target sequences were detected by simple delivery of sample solutions onto DNA probe-functionalized Nanowave chips and SERS signals were measured after 1h - 2h incubation. Target sequence labeling or washing to remove unreacted components was not required, making the techniques simple, easy-to-use, and cost effective. The usefulness of the techniques for medical diagnostics was illustrated by the detection of genetic biomarkers for respiratory viral infection and of dengue virus 4 DNA.
Singh, P C; Nautiyal, C S
2012-12-01
To prepare concentrated formulation of Trichoderma harzianum MTCC-3841 (NBRI-1055) with high colony forming units (CFU), long shelf life and efficient in root colonization by a simple scrapping method. NBRI-1055 spores scrapped from potato dextrose agar plates were used to prepare a concentrated formulation after optimizing carrier material, moisture content and spore harvest time. The process provides an advantage of maintaining optimum moisture level by the addition of water rather than dehydration. The formulation had an initial 11-12 log(10) CFU g(-1). Its concentrated form reduces its application amount by 100 times (10 g 100 kg(-1) seed) and provides 3-4 log(10) CFU seed(-1). Shelf life of the product was experimentally determined at 30 and 40 °C and predicted at other temperatures following Arrhenius equation. The concentrated formulation as compared to similar products provides an extra advantage of smaller packaging for storage and transportation, cutting down product cost. Seed application of the formulation recorded significant increase in plant growth promotion. Stable and effective formulation of Trichoderma harzianum NBRI-1055 was obtained by a simple scrapping method. A new method for the production of concentrated, stable, effective and cost efficient formulation of T. harzianum has been validated for seed application. © 2012 The Society for Applied Microbiology.
Chorioallantoic membrane for in vivo investigation of tissue-engineered construct biocompatibility.
Baiguera, Silvia; Macchiarini, Paolo; Ribatti, Domenico
2012-07-01
In tissue engineering approach, the scaffold plays a key role for a suitable outcome of cell-scaffold interactions and for the success of tissue healing and regeneration. As a consequence, the characterization of scaffold properties and the in vivo evaluation of tissue responses and effects result to be essential in the development of suitable implantable device. Among the in vivo methods, the chick embryo chorioallantoic membrane (CAM) assay represents a rather simple and cost-effective procedure to study the biocompatibility responses of graft materials. CAM is indeed characterized by low experiment costs, simplicity, relative speed in obtaining the expected results, limited ethical concern, no need of high-level technical skill, and the absence of a mature immune system, resulting in an inexpensive, simple, and practical method to evaluate and characterize tissue-engineered constructs. The results till now obtained suggest that CAM assay can be used as a pre-screening assay, before in vivo animal studies, to determine whether the scaffold is liable to cause an adverse reaction and to evaluate its future enhancement of existing materials for tissue engineering. A review of the more recent results related to the use of CAM for in vivo biomaterial property evaluation is herein reported. Copyright © 2012 Wiley Periodicals, Inc.
A piezo-ring-on-chip microfluidic device for simple and low-cost mass spectrometry interfacing.
Tsao, Chia-Wen; Lei, I-Chao; Chen, Pi-Yu; Yang, Yu-Liang
2018-02-12
Mass spectrometry (MS) interfacing technology provides the means for incorporating microfluidic processing with post MS analysis. In this study, we propose a simple piezo-ring-on-chip microfluidic device for the controlled spraying of MALDI-MS targets. This device uses a low-cost, commercially-available ring-shaped piezoelectric acoustic atomizer (piezo-ring) directly integrated into a polydimethylsiloxane microfluidic device to spray the sample onto the MS target substrate. The piezo-ring-on-chip microfluidic device's design, fabrication, and actuation, and its pulsatile pumping effects were evaluated. The spraying performance was examined by depositing organic matrix samples onto the MS target substrate by using both an automatic linear motion motor, and manual deposition. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was performed to analyze the peptide samples on the MALDI target substrates. Using our technique, model peptides with 10 -6 M concentration can be successfully detected. The results also indicate that the piezo-ring-on-chip approach forms finer matrix crystals and presents better MS signal uniformity with little sample consumption compared to the conventional pipetting method.
Facile fabrication of CNT-based chemical sensor operating at room temperature
NASA Astrophysics Data System (ADS)
Sheng, Jiadong; Zeng, Xian; Zhu, Qi; Yang, Zhaohui; Zhang, Xiaohua
2017-12-01
This paper describes a simple, low cost and effective route to fabricate CNT-based chemical sensors, which operate at room temperature. Firstly, the incorporation of silk fibroin in vertically aligned CNT arrays (CNTA) obtained through a thermal chemical vapor deposition (CVD) method makes the direct removal of CNT arrays from substrates without any rigorous acid or sonication treatment feasible. Through a simple one-step in situ polymerization of anilines, the functionalization of CNT arrays with polyaniline (PANI) significantly improves the sensing performance of CNT-based chemical sensors in detecting ammonia (NH3) and hydrogen chloride (HCl) vapors. Chemically modified CNT arrays also show responses to organic vapors like menthol, ethyl acetate and acetone. Although the detection limits of chemically modified CNT-based chemical sensors are of the same orders of magnitudes reported in previous studies, these CNT-based chemical sensors show advantages of simplicity, low cost and energy efficiency in preparation and fabrication of devices. Additionally, a linear relationship between the relative sensitivity and concentration of analyte makes precise estimations on the concentrations of trace chemical vapors possible.
Small-Scale and Low Cost Electrodes for "Standard" Reduction Potential Measurements
ERIC Educational Resources Information Center
Eggen, Per-Odd; Kvittingen, Lise
2007-01-01
The construction of three simple and inexpensive electrodes, hydrogen, and chlorine and copper electrode is described. This simple method will encourage students to construct their own electrode and better help in understanding precipitation and other electrochemistry concepts.
An Inexpensive Robotics Laboratory.
ERIC Educational Resources Information Center
Inigo, R. M.; Angulo, J. M.
1985-01-01
Describes the design and implementation of a simple robot manipulator. The manipulator has three degrees of freedom and is controlled by a general purpose microcomputer. The basis for the manipulator (which costs under $100) is a simple working model of a crane. (Author/JN)
Lin, Yu-Shiuan; Jan, I-Shiow; Cheng, Shou-Hsia
2017-03-01
Generic medications used for chronic diseases are beneficial in containing healthcare costs and improving drug accessibility. However, the effects of generic drugs in acute and severe illness remain controversial. This study aims to investigate treatment costs and outcomes of generic antibiotics prescribed for adults with a urinary tract infection in outpatient settings. The data source was the Longitudinal Health Insurance Database of Taiwan. We included outpatients aged 20 years and above with a urinary tract infection who required one oral antibiotic for which brand-name and generic products were simultaneously available. Drug cost and overall healthcare expense of the index consultation, healthcare cost during a 42-day follow-up period, and treatment failure rates were the main dependent variables. Data were compared between brand-name and generic users from the entire cohort and a propensity score-matched samples. Results from the entire cohort and propensity score-matched samples were similar. Daily antibiotic cost was significantly lower among generic users than brand-name users. Significant lower total drug claims of the index consultation only existed in patients receiving the investigated antibiotics, while the drug price between brand-name and generic versions were relatively large (e.g., >50%). The overall healthcare cost of the index consultation, healthcare expenditure during a 42-day follow-up period, and treatment failure rates were similar between the two groups. Compared with those treated with brand-name antibiotics, outpatients who received generic antibiotics had equivalent treatment outcomes with lower drug costs. Generic antibiotics are effective and worthy of adoption among outpatients with simple infections indicating oral antibiotic treatment. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Optimal joint management of a coastal aquifer and a substitute resource
NASA Astrophysics Data System (ADS)
Moreaux, M.; Reynaud, A.
2004-06-01
This article characterizes the optimal joint management of a coastal aquifer and a costly water substitute. For this purpose we use a mathematical representation of the aquifer that incorporates the displacement of the interface between the seawater and the freshwater of the aquifer. We identify the spatial cost externalities created by users on each other and we show that the optimal water supply depends on the location of users. Users located in the coastal zone exclusively use the costly substitute. Those located in the more upstream area are supplied from the aquifer. At the optimum their withdrawal must take into account the cost externalities they generate on users located downstream. Last, users located in a median zone use the aquifer with a surface transportation cost. We show that the optimum can be implemented in a decentralized economy through a very simple Pigouvian tax. Finally, the optimal and decentralized extraction policies are simulated on a very simple example.
Natural wind variability triggered drop in German redispatch volume and costs from 2015 to 2016.
Wohland, Jan; Reyers, Mark; Märker, Carolin; Witthaut, Dirk
2018-01-01
Avoiding dangerous climate change necessitates the decarbonization of electricity systems within the next few decades. In Germany, this decarbonization is based on an increased exploitation of variable renewable electricity sources such as wind and solar power. While system security has remained constantly high, the integration of renewables causes additional costs. In 2015, the costs of grid management saw an all time high of about € 1 billion. Despite the addition of renewable capacity, these costs dropped substantially in 2016. We thus investigate the effect of natural climate variability on grid management costs in this study. We show that the decline is triggered by natural wind variability focusing on redispatch as a main cost driver. In particular, we find that 2016 was a weak year in terms of wind generation averages and the occurrence of westerly circulation weather types. Moreover, we show that a simple model based on the wind generation time series is skillful in detecting redispatch events on timescales of weeks and beyond. As a consequence, alterations in annual redispatch costs in the order of hundreds of millions of euros need to be understood and communicated as a normal feature of the current system due to natural wind variability.
A Cost Estimation Tool for Charter Schools
ERIC Educational Resources Information Center
Hayes, Cheryl D.; Keller, Eric
2009-01-01
To align their financing strategies and fundraising efforts with their fiscal needs, charter school leaders need to know how much funding they need and what that funding will support. This cost estimation tool offers a simple set of worksheets to help start-up charter school operators identify and estimate the range of costs and timing of…
NASA Technical Reports Server (NTRS)
Chamberlain, R. G.; Aster, R. W.; Firnett, P. J.; Miller, M. A.
1985-01-01
Improved Price Estimation Guidelines, IPEG4, program provides comparatively simple, yet relatively accurate estimate of price of manufactured product. IPEG4 processes user supplied input data to determine estimate of price per unit of production. Input data include equipment cost, space required, labor cost, materials and supplies cost, utility expenses, and production volume on industry wide or process wide basis.
ERIC Educational Resources Information Center
Chen, Huai-Yi; Nieh, Hwa-Ming; Yang, Ming-Feng; Chou, Yu-Kung; Chung, Jui-Hsu; Liou, Je-Wen
2016-01-01
This study proposes a home-assembled, low-cost blue light-emitting diode (LED) photometer that uses simple and low-cost hardware and software, costing about US $150. This 425-nm wavelength photometer is controlled by an 89C51 microcontroller chip. Glucose concentration detection experiments involving enzyme coupling reactions were carried out to…
Frischer, Robert; Penhaker, Marek; Krejcar, Ondrej; Kacerovsky, Marian; Selamat, Ali
2014-01-01
Precise temperature measurement is essential in a wide range of applications in the medical environment, however the regarding the problem of temperature measurement inside a simple incubator, neither a simple nor a low cost solution have been proposed yet. Given that standard temperature sensors don't satisfy the necessary expectations, the problem is not measuring temperature, but rather achieving the desired sensitivity. In response, this paper introduces a novel hardware design as well as the implementation that increases measurement sensitivity in defined temperature intervals at low cost. PMID:25494352
Tregenza, Tom; Wedell, Nina; Hosken, David J; Ward, Paul I
2003-02-01
Direct costs and benefits to females of multiple mating have been shown to have large effects on female fecundity and longevity in several species. However, with the exception of studies examining genetic benefits of polyandry, little attention has been paid to the possible effects on offspring of multiple mating by females. We propose that nongenetic effects of maternal matings on offspring fitness are best viewed in the same context as other maternal phenotype effects on offspring that are well known even in species lacking parental care. Hence, matings can exert effects on offspring in the same way as other maternal environment variables, and are likely to interact with such effects. We have conducted a study using yellow dung flies (Scathophaga stercoraria), in which we independently manipulated female mating rate, number of mates and maternal thermal environment and measured subsequent fecundity, hatching success, and offspring life-history traits. To distinguish between direct effects of matings and potential genetic benefits of polyandry we split broods and reared offspring at three different temperature regimes. This allowed us to demonstrate that although we could not detect any simple benefits or costs to matings, there are effects of maternal environment on offspring and these effects interact with female mating regime affecting offspring fitness. Such interactions between female phenotype and the costs and benefits of matings have potentially broad implications for understanding female behavior.
Simple glucose reduction route for one-step synthesis of copper nanofluids
NASA Astrophysics Data System (ADS)
Shenoy, U. Sandhya; Shetty, A. Nityananda
2014-01-01
One-step method has been employed in the synthesis of copper nanofluids. Copper nitrate is reduced by glucose in the presence of sodium lauryl sulfate. The synthesized particles are characterized by X-ray diffraction technique for the phase structure; electron diffraction X-ray analysis for chemical composition; transmission electron microscopy and field emission scanning electron microscopy for the morphology; Fourier-transform infrared spectroscopy and ultraviolet-visible spectroscopy for the analysis of ingredients of the solution. Thermal conductivity, sedimentation and rheological measurements have also been carried out. It is found that the reaction parameters have considerable effect on the size of the particle formed and rate of the reaction. The techniques confirm that the synthesized particles are copper. The reported method showed promising increase in the thermal conductivity of the base fluid and is found to be reliable, simple and cost-effective method for preparing heat transfer fluids with higher stability.
Interconnected V2O5 nanoporous network for high-performance supercapacitors.
Saravanakumar, B; Purushothaman, Kamatchi K; Muralidharan, G
2012-09-26
Vanadium pentoxide (V(2)O(5)) has attracted attention for supercapcitor applications because of its extensive multifunctional properties. In the present study, V(2)O(5) nanoporous network was synthesized via simple capping-agent-assisted precipitation technique and it is further annealed at different temperatures. The effect of annealing temperature on the morphology, electrochemical and structural properties, and stability upon oxidation-reduction cycling has been analyzed for supercapacitor application. We achieved highest specific capacitance of 316 F g(-1) for interconnected V(2)O(5) nanoporous network. This interconnected nanoporous network creates facile nanochannels for ion diffusion and facilitates the easy accessibility of ions. Moreover, after six hundred consecutive cycling processes the specific capacitance has changed only by 24%. A simple cost-effective preparation technique of V(2)O(5) nanoporous network with excellent capacitive behavior, energy density, and stability encourages its possible commercial exploitation for the development of high-performance supercapacitors.
Kowalczyk, Wojciech; Rybicki, Zbigniew; Tomaszewski, Dariusz; Truszczyński, Andrzej; Guzek, Aneta
2011-01-01
Although broncho-alveolar lavage (BAL) culture and protected specimen brush (PSB) are regarded as the most effective methods in the diagnosis of VAP, a simple endotracheal aspiration (EA) is frequently performed during routine care, because of its simplicity and low cost. We compared the effectiveness of EA with BAL and PSB in VAP patients. Sixty-one adult VAP patients, ventilated for longer than 48 h, were cultured with all three methods. Positive cultures were obtained from 63.9% of patients, with Acinetobacter baumannii being the most common pathogen. There was a high positive correlation between simple aspirates and BAL (k 0.817, CI 0.664-0.840, p <0.001) and aspirates and PSB (k 0.667, CI 0.483-0.871, p <0.001). Because of the high sensitivity of bronchial aspirate culturing, compared to BAL and PSB, it can be used successfully in most cases.
Distillation Apparatuses Using Household Items
NASA Astrophysics Data System (ADS)
Campanizzi, Danielle R. D.; Mason, Brenda; Hermann, Christine K. F.
1999-08-01
A simple apparatus to demonstrate distillation principles can be very difficult to build without the specialty glassware found in chemistry laboratories. We have built inexpensive but effective distillation apparatuses from equipment that can be easily purchased at local department, grocery, or hardware stores. In one apparatus, colored water is heated to boiling and the condensed vapors drip into another container. In another apparatus, acetone is heated to boiling with hot water and the acetone vapors condense onto a Styrofoam cup. The Styrofoam cup is softened by the acetone and collapses. Rubbing alcohol can be used instead of acetone, but the cup is not softened and the boiling point is much higher. Both apparatuses can be used in a classroom. Both are simple, cost-effective ways of demonstrating distillation, evaporation, and condensation. They would be ideal to use in elementary and middle school classrooms when explaining these concepts.
Biomimetic small scale variable focal length lens unit using synthetic elastomer actuators
NASA Astrophysics Data System (ADS)
Kim, Baek-chul; Chung, Jinah; Lee, Y.; Nam, Jae-Do; Moon, Hyungpil; Choi, Hyouk Ryeol; Koo, J. C.
2011-04-01
Having a combination of a gel-like soft lens, ligaments, and the Ciliary muscles, the human eyes are effectively working for various focal lengths without a complicated group of lens. The simple and compact but effective optical system should deserve numerous attentions from various technical field especially portable information technology device industry. Noting the limited physical space of those deivces, demanding shock durability, and massive volume productivity, the present paper proposes a biomimetic optical lens unit that is organized with a circular silicone lens and an annular dielectric polymer actuator. Unlike the traditional optical lens mechanism that normally acquires a focus by changing its focal distance with moving lens or focal plane. the proposed optical system changes its lens thickness using a annulary connected polymer actuator in order to get image focuses. The proposed biomimetic lens system ensures high shock durability, compact physical dimensions, fast actuations, simple manufacturing process, and low production cost.
Kidwell, Mallory C.; Lazarević, Ljiljana B.; Baranski, Erica; Piechowski, Sarah; Falkenberg, Lina-Sophia; Sonnleitner, Carina; Fiedler, Susann; Nosek, Brian A.
2016-01-01
Beginning January 2014, Psychological Science gave authors the opportunity to signal open data and materials if they qualified for badges that accompanied published articles. Before badges, less than 3% of Psychological Science articles reported open data. After badges, 23% reported open data, with an accelerating trend; 39% reported open data in the first half of 2015, an increase of more than an order of magnitude from baseline. There was no change over time in the low rates of data sharing among comparison journals. Moreover, reporting openness does not guarantee openness. When badges were earned, reportedly available data were more likely to be actually available, correct, usable, and complete than when badges were not earned. Open materials also increased to a weaker degree, and there was more variability among comparison journals. Badges are simple, effective signals to promote open practices and improve preservation of data and materials by using independent repositories. PMID:27171007
Systematic review of cost effectiveness studies of telemedicine interventions
Whitten, Pamela S; Mair, Frances S; Haycox, Alan; May, Carl R; Williams, Tracy L; Hellmich, Seth
2002-01-01
Objectives To systematically review cost benefit studies of telemedicine. Design Systematic review of English language, peer reviewed journal articles. Data sources Searches of Medline, Embase, ISI citation indexes, and database of Telemedicine Information Exchange. Studies selected 55 of 612 identified articles that presented actual cost benefit data. Main outcome measures Scientific quality of reports assessed by use of an established instrument for adjudicating on the quality of economic analyses. Results 557 articles without cost data categorised by topic. 55 articles with data initially categorised by cost variables employed in the study and conclusions. Only 24/55 (44%) studies met quality criteria justifying inclusion in a quality review. 20/24 (83%) restricted to simple cost comparisons. No study used cost utility analysis, the conventional means of establishing the “value for money” that a therapeutic intervention represents. Only 7/24 (29%) studies attempted to explore the level of utilisation that would be needed for telemedicine services to compare favourably with traditionally organised health care. None addressed this question in sufficient detail to adequately answer it. 15/24 (62.5%) of articles reviewed here provided no details of sensitivity analysis, a method all economic analyses should incorporate. Conclusion There is no good evidence that telemedicine is a cost effective means of delivering health care. What is already known on this topicThe use of telemedicine has garnered much attention in the past decadeHundreds of articles have been published claiming that telemedicine is cost effectiveHowever, missing from the literature is a synthesis or meta-analysis of these publicationsWhat this study addsA comprehensive literature search of cost related articles on telemedicine identified more than 600 articles, but only 9% contained any cost benefit dataOnly 4% of these articles met quality criteria justifying inclusion in a formalised quality review, and most of these were small scale, short term, pragmatic evaluations with few generalisable conclusionsThere is little published evidence to confirm whether or not telemedicine is a cost effective alternative to standard healthcare delivery PMID:12065269
Could CT screening for lung cancer ever be cost effective in the United Kingdom?
Whynes, David K
2008-01-01
Background The absence of trial evidence makes it impossible to determine whether or not mass screening for lung cancer would be cost effective and, indeed, whether a clinical trial to investigate the problem would be justified. Attempts have been made to resolve this issue by modelling, although the complex models developed to date have required more real-world data than are currently available. Being founded on unsubstantiated assumptions, they have produced estimates with wide confidence intervals and of uncertain relevance to the United Kingdom. Method I develop a simple, deterministic, model of a screening regimen potentially applicable to the UK. The model includes only a limited number of parameters, for the majority of which, values have already been established in non-trial settings. The component costs of screening are derived from government guidance and from published audits, whilst the values for test parameters are derived from clinical studies. The expected health gains as a result of screening are calculated by combining published survival data for screened and unscreened cohorts with data from Life Tables. When a degree of uncertainty over a parameter value exists, I use a conservative estimate, i.e. one likely to make screening appear less, rather than more, cost effective. Results The incremental cost effectiveness ratio of a single screen amongst a high-risk male population is calculated to be around £14,000 per quality-adjusted life year gained. The average cost of this screening regimen per person screened is around £200. It is possible that, when obtained experimentally in any future trial, parameter values will be found to differ from those previously obtained in non-trial settings. On the basis both of differing assumptions about evaluation conventions and of reasoned speculations as to how test parameters and costs might behave under screening, the model generates cost effectiveness ratios as high as around £20,000 and as low as around £7,000. Conclusion It is evident that eventually being able to identify a cost effective regimen of CT screening for lung cancer in the UK is by no means an unreasonable expectation. PMID:18302756
NASA Astrophysics Data System (ADS)
Robertson, Randolph B.
This study investigates the impact of concurrent design on the cost growth and schedule growth of US Department of Defense Major Defense Acquisition Systems (MDAPs). It is motivated by the question of whether employment of concurrent design in the development of a major weapon system will produce better results in terms of cost and schedule than traditional serial development methods. Selected Acquisition Reports were used to determine the cost and schedule growth of MDAPs as well as the degree of concurrency employed. Two simple linear regression analyses were used to determine the degree to which cost growth and schedule growth vary with concurrency. The results were somewhat surprising in that for major weapon systems the utilization of concurrency as it was implemented in the programs under study was shown to have no effect on cost performance, and that performance to development schedule, one of the purported benefits of concurrency, was actually shown to deteriorate with increases in concurrency. These results, while not an indictment of the concept of concurrency, indicate that better practices and methods are needed in the implementation of concurrency in major weapon systems. The findings are instructive to stakeholders in the weapons acquisition process in their consideration of whether and how to employ concurrent design strategies in their planning of new weapons acquisition programs.
Toward an affordable and user-friendly visual motion capture system.
Bonnet, V; Sylla, N; Cherubini, A; Gonzáles, A; Azevedo Coste, C; Fraisse, P; Venture, G
2014-01-01
The present study aims at designing and evaluating a low-cost, simple and portable system for arm joint angle estimation during grasping-like motions. The system is based on a single RGB-D camera and three customized markers. The automatically detected and tracked marker positions were used as inputs to an offline inverse kinematic process based on bio-mechanical constraints to reduce noise effect and handle marker occlusion. The method was validated on 4 subjects with different motions. The joint angles were estimated both with the proposed low-cost system and, a stereophotogrammetric system. Comparative analysis shows good accuracy with high correlation coefficient (r= 0.92) and low average RMS error (3.8 deg).
NASA SensorWeb and OGC Standards for Disaster Management
NASA Technical Reports Server (NTRS)
Mandl, Dan
2010-01-01
I. Goal: Enable user to cost-effectively find and create customized data products to help manage disasters; a) On-demand; b) Low cost and non-specialized tools such as Google Earth and browsers; c) Access via open network but with sufficient security. II. Use standards to interface various sensors and resultant data: a) Wrap sensors in Open Geospatial Consortium (OGC) standards; b) Wrap data processing algorithms and servers with OGC standards c) Use standardized workflows to orchestrate and script the creation of these data; products. III. Target Web 2.0 mass market: a) Make it simple and easy to use; b) Leverage new capabilities and tools that are emerging; c) Improve speed and responsiveness.
Vial OrganicTM-Organic Chemistry Labs for High School and Junior College
NASA Astrophysics Data System (ADS)
Russo, Thomas J.; Meszaros, Mark
1999-01-01
Vial Organic is the most economical, safe, and time-effective method of performing organic chemistry experiments. Activities are carried out in low-cost, sealed vials. Vial Organic is extremely safe because only micro quantities of reactants are used, reactants are contained in tightly sealed vials, and only water baths are used for temperature control. Vial Organic laboratory activities are easily performed within one 50-minute class period. When heat is required, a simple hot-water bath is prepared from a beaker of water and an inexpensive immersion heater. The low cost, ease of use, and relatively short time requirement will allow organic chemistry to be experienced by more students with less confusion and intimidation.
Plastic masters-rigid templates for soft lithography.
Desai, Salil P; Freeman, Dennis M; Voldman, Joel
2009-06-07
We demonstrate a simple process for the fabrication of rigid plastic master molds for soft lithography directly from (poly)dimethysiloxane devices. Plastics masters (PMs) provide a cost-effective alternative to silicon-based masters and can be easily replicated without the need for cleanroom facilities. We have successfully demonstrated the use of plastics micromolding to generate both single and dual-layer plastic structures, and have characterized the fidelity of the molding process. Using the PM fabrication technique, world-to-chip connections can be integrated directly into the master enabling devices with robust, well-aligned fluidic ports directly after molding. PMs provide an easy technique for the fabrication of microfluidic devices and a simple route for the scaling-up of fabrication of robust masters for soft lithography.
Zhang, Xiaomei; Yu, Hongwen; Yang, Hongjun; Wan, Yuchun; Hu, Hong; Zhai, Zhuang; Qin, Jieming
2015-01-01
A simple sol-gel method using non-toxic and cost-effective precursors has been developed to prepare graphene oxide (GO)/cellulose bead (GOCB) composites for removal of dye pollutants. Taking advantage of the combined benefits of GO and cellulose, the prepared GOCB composites exhibit excellent removal efficiency towards malachite green (>96%) and can be reused for over 5 times through simple filtration method. The high-decontamination performance of the GOCB system is strongly dependent on encapsulation amount of GO, temperature and pH value. In addition, the adsorption behavior of this new adsorbent fits well with the Langmuir isotherm and pseudo-second-order kinetic model. Copyright © 2014 Elsevier Inc. All rights reserved.
Advantages and disadvantages of endoscopically assisted front-lift.
Dusková, M; Padĕra, J; Kristen, M
2002-01-01
Reduced surgical risk, a diminution of visible scars, rapid recovery, long-termed results and reduced costs are at present the most important demands on development in aesthetic plastic surgery. Endoscopically assisted front-lift meets perfectly the need of reduced invasiveness. It is technically simple and associated with a minimum of complications. It brings minimal scars beyond the hairline with a favourable effect after eliminating the drop of the brows, and wrinkles on the forehead. The duration of the effect in the aging face depends, however, similarly as other methods, on the characteristics of the skin, changes in other parts and the individual disposition. A marked disadvantage is the high initial, cost of special equipment. Their recovery ensues from the reduced time of surgery, reduced consumption of material, lower number of complications and more rapid return to normal life.
Human cooperation based on punishment reputation.
dos Santos, Miguel; Rankin, Daniel J; Wedekind, Claus
2013-08-01
The threat of punishment usually promotes cooperation. However, punishing itself is costly, rare in nonhuman animals, and humans who punish often finish with low payoffs in economic experiments. The evolution of punishment has therefore been unclear. Recent theoretical developments suggest that punishment has evolved in the context of reputation games. We tested this idea in a simple helping game with observers and with punishment and punishment reputation (experimentally controlling for other possible reputational effects). We show that punishers fully compensate their costs as they receive help more often. The more likely defection is punished within a group, the higher the level of within-group cooperation. These beneficial effects perish if the punishment reputation is removed. We conclude that reputation is key to the evolution of punishment. © 2013 The Author(s). Evolution © 2013 The Society for the Study of Evolution.
NASA Astrophysics Data System (ADS)
Kulkarni, Swati S.; Bodkhe, Gajanan A.; Shirsat, Sumedh M.; Hussaini, S. S.; Shejwal, N. N.; Shirsat, Mahendra D.
2018-03-01
Present communication deals with the development of cost effective dye sensitized solar cell (DSSC) with eco-friendly materials. Eco-friendly Eosin Y dye was used to sensitize photo anode which was fabricated using undoped and Aluminium doped titanium dioxide (TiO2) nanoparticles. Undoped and Aluminium doped TiO2 nanoparticles were synthesized by simple and cost effective sol-gel method. Aluminium doped and undoped TiO2 nanoparticles were characterized using UV-visible, FT-IR spectroscopy, x-ray Diffraction, and Scanning Electron Micrograph with EDX. The photo-voltaic activity of the cell was studied under light irradiation of 100 milliwatt cm-2. Aluminium doped TiO2 nanoparticle photo electrode exhibits more than 60% increase in cell efficiency as compared to the undoped TiO2 nanoparticle photo electrode.
Direct laser writing of polymeric nanostructures via optically induced local thermal effect
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tong, Quang Cong; Institute of Materials Science, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay, 10000 Hanoi; Nguyen, Dam Thuy Trang
We demonstrate the fabrication of desired structures with feature size below the diffraction limit by use of a positive photoresist. The direct laser writing technique employing a continuous-wave laser was used to optically induce a local thermal effect in a positive photoresist, which then allowed the formation of solid nanostructures. This technique enabled us to realize multi-dimensional sub-microstructures by use of a positive photoresist, with a feature size down to 57 nm. This mechanism acting on positive photoresists opens a simple and low-cost way for nanofabrication.
Profitable capitation requires accurate costing.
West, D A; Hicks, L L; Balas, E A; West, T D
1996-01-01
In the name of costing accuracy, nurses are asked to track inventory use on per treatment basis when more significant costs, such as general overhead and nursing salaries, are usually allocated to patients or treatments on an average cost basis. Accurate treatment costing and financial viability require analysis of all resources actually consumed in treatment delivery, including nursing services and inventory. More precise costing information enables more profitable decisions as is demonstrated by comparing the ratio-of-cost-to-treatment method (aggregate costing) with alternative activity-based costing methods (ABC). Nurses must participate in this costing process to assure that capitation bids are based upon accurate costs rather than simple averages.
Suo, Guoquan; Yu, Yanhao; Zhang, Zhiyi; Wang, Shifa; Zhao, Ping; Li, Jianye; Wang, Xudong
2016-12-21
Piezoelectric and triboelectric nanogenerators have been developed as rising energy-harvesting devices in the past few years to effectively convert mechanical energy into electricity. Here, a novel hybrid piezo/triboelectric nanogenerator based on BaTiO 3 NP/PDMS composite film was developed in a simple and low-cost way. The effects of the BTO content and polarization degree on the output performance were systematically studied. The device with 20 wt % BTO in PDMS and a 100-μm-thick film showed the highest output power. We also designed three measurement modes to record hybrid, triboelectric, and piezoelectric outputs separately with a simple structure that has only two electrodes. The hybrid output performance is higher than the tribo- and piezoelectric performances. This work will provide not only a new way to enhance the output power of nanogenerators, but also new opportunities for developing built-in power sources in self-powered electronics.
A simple, low-cost, data logging pendulum built from a computer mouse
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gintautas, Vadas; Hubler, Alfred
Lessons and homework problems involving a pendulum are often a big part of introductory physics classes and laboratory courses from high school to undergraduate levels. Although laboratory equipment for pendulum experiments is commercially available, it is often expensive and may not be affordable for teachers on fixed budgets, particularly in developing countries. We present a low-cost, easy-to-build rotary sensor pendulum using the existing hardware in a ball-type computer mouse. We demonstrate how this apparatus may be used to measure both the frequency and coefficient of damping of a simple physical pendulum. This easily constructed laboratory equipment makes it possible formore » all students to have hands-on experience with one of the most important simple physical systems.« less
Naval Surface Forces Real-Time Reutilization Asset Management Warehouses: A Cost-Benefit Analysis
2008-12-01
shared their valuable insights. And finally, to our advisors Dr . Ken Euske and CDR Brett Wagner who kept us on track throughout the project. Nick could...of $206,368,657. SURFOR’s East and West Coast warehouses accounted for $146,975,108 of the list value. The team identified potential cost...obligating the funds. A relatively simple cost benefit analysis of the reprogramming costs versus the cost savings would justify the expense. In the
Su, Bin-Guang; Chen, Shao-Fen; Yeh, Shu-Hsing; Shih, Po-Wen; Lin, Ching-Chiang
2016-11-01
To cope with the government's policies to reduce medical costs, Taiwan's healthcare service providers are striving to survive by pursuing profit maximization through cost control. This article aimed to present the results of cost evaluation using activity-based costing performed in the laboratory in order to throw light on the differences between costs and the payment system of National Health Insurance (NHI). This study analyzed the data of costs and income of the clinical laboratory. Direct costs belong to their respective sections of the department. The department's shared costs, including public expenses and administrative assigned costs, were allocated to the department's respective sections. A simple regression equation was created to predict profit and loss, and evaluate the department's break-even point, fixed cost, and contribution margin ratio. In clinical chemistry and seroimmunology sections, the cost per test was lower than the NHI payment and their major laboratory tests had revenues with the profitability ratio of 8.7%, while the other sections had a higher cost per test than the NHI payment and their major tests were in deficit. The study found a simple linear regression model as follows: "Balance=-84,995+0.543×income (R2=0.544)". In order to avoid deficit, laboratories are suggested to increase test volumes, enhance laboratory test specialization, and become marginal scale. A hospital could integrate with regional medical institutions through alliances or OEM methods to increase volumes to reach marginal scale and reduce laboratory costs, enhancing the level and quality of laboratory medicine.
Proposal to upgrade the MIPP data acquisition system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, W.; Carey, D.; Johnstone, C.
2005-03-01
The MIPP TPC is the largest contributor to the MIPP event size by far. Its readout system and electronics were designed in the 1990's and limit it to a readout rate of 60 Hz in simple events and {approx} 20 Hz in complicated events. With the readout chips designed for the ALICE collaboration at the LHC, we propose a low cost effective scheme of upgrading the MIPP data acquisition speed to 3000 Hz.
Keep it simple? Predicting primary health care costs with clinical morbidity measures
Brilleman, Samuel L.; Gravelle, Hugh; Hollinghurst, Sandra; Purdy, Sarah; Salisbury, Chris; Windmeijer, Frank
2014-01-01
Models of the determinants of individuals’ primary care costs can be used to set capitation payments to providers and to test for horizontal equity. We compare the ability of eight measures of patient morbidity and multimorbidity to predict future primary care costs and examine capitation payments based on them. The measures were derived from four morbidity descriptive systems: 17 chronic diseases in the Quality and Outcomes Framework (QOF); 17 chronic diseases in the Charlson scheme; 114 Expanded Diagnosis Clusters (EDCs); and 68 Adjusted Clinical Groups (ACGs). These were applied to patient records of 86,100 individuals in 174 English practices. For a given disease description system, counts of diseases and sets of disease dummy variables had similar explanatory power. The EDC measures performed best followed by the QOF and ACG measures. The Charlson measures had the worst performance but still improved markedly on models containing only age, gender, deprivation and practice effects. Comparisons of predictive power for different morbidity measures were similar for linear and exponential models, but the relative predictive power of the models varied with the morbidity measure. Capitation payments for an individual patient vary considerably with the different morbidity measures included in the cost model. Even for the best fitting model large differences between expected cost and capitation for some types of patient suggest incentives for patient selection. Models with any of the morbidity measures show higher cost for more deprived patients but the positive effect of deprivation on cost was smaller in better fitting models. PMID:24657375
Low cost voice compression for mobile digital radios
NASA Technical Reports Server (NTRS)
Omura, J. K.
1985-01-01
A new technique for low cost rubust voice compression at 4800 bits per second was studied. The approach was based on using a cascade of digital biquad adaptive filters with simplified multipulse excitation followed by simple bit sequence compression.
System cost/performance analysis (study 2.3). Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
Kazangey, T.
1973-01-01
The relationships between performance, safety, cost, and schedule parameters were identified and quantified in support of an overall effort to generate program models and methodology that provide insight into a total space vehicle program. A specific space vehicle system, the attitude control system (ACS), was used, and a modeling methodology was selected that develops a consistent set of quantitative relationships among performance, safety, cost, and schedule, based on the characteristics of the components utilized in candidate mechanisms. These descriptive equations were developed for a three-axis, earth-pointing, mass expulsion ACS. A data base describing typical candidate ACS components was implemented, along with a computer program to perform sample calculations. This approach, implemented on a computer, is capable of determining the effect of a change in functional requirements to the ACS mechanization and the resulting cost and schedule. By a simple extension of this modeling methodology to the other systems in a space vehicle, a complete space vehicle model can be developed. Study results and recommendations are presented.
Smith, Cynthia D
2012-08-21
Health care expenditures are projected to reach nearly 20% of the U.S. gross domestic product by 2020. Up to $765 billion of this spending has been identified as potentially avoidable; many of the avoidable costs have been attributed to unnecessary services. Postgraduate trainees have historically received little specific training in the stewardship of health care resources and minimal feedback on resource utilization and its effect on the cost of care. This article describes a new curriculum that was developed collaboratively by the Alliance for Academic Internal Medicine and the American College of Physicians to address this training gap. The curriculum introduces a simple, stepwise framework for delivering high-value care and focuses on teaching trainees to incorporate high-value, cost-conscious care principles into their clinical practice. It consists of ten 1-hour, case-based, interactive sessions designed to be flexibly incorporated into the existing conference structure of a residency training program.
HIV Treatment and Prevention: A Simple Model to Determine Optimal Investment.
Juusola, Jessie L; Brandeau, Margaret L
2016-04-01
To create a simple model to help public health decision makers determine how to best invest limited resources in HIV treatment scale-up and prevention. A linear model was developed for determining the optimal mix of investment in HIV treatment and prevention, given a fixed budget. The model incorporates estimates of secondary health benefits accruing from HIV treatment and prevention and allows for diseconomies of scale in program costs and subadditive benefits from concurrent program implementation. Data sources were published literature. The target population was individuals infected with HIV or at risk of acquiring it. Illustrative examples of interventions include preexposure prophylaxis (PrEP), community-based education (CBE), and antiretroviral therapy (ART) for men who have sex with men (MSM) in the US. Outcome measures were incremental cost, quality-adjusted life-years gained, and HIV infections averted. Base case analysis indicated that it is optimal to invest in ART before PrEP and to invest in CBE before scaling up ART. Diseconomies of scale reduced the optimal investment level. Subadditivity of benefits did not affect the optimal allocation for relatively low implementation levels. The sensitivity analysis indicated that investment in ART before PrEP was optimal in all scenarios tested. Investment in ART before CBE became optimal when CBE reduced risky behavior by 4% or less. Limitations of the study are that dynamic effects are approximated with a static model. Our model provides a simple yet accurate means of determining optimal investment in HIV prevention and treatment. For MSM in the US, HIV control funds should be prioritized on inexpensive, effective programs like CBE, then on ART scale-up, with only minimal investment in PrEP. © The Author(s) 2015.
Sateanchok, Suphasinee; Wangkarn, Sunanta; Saenjum, Chalermpong; Grudpan, Kate
2018-01-15
A cost-effective assay for antioxidant using simple cotton thread combining paper based device with mobile phone detection has been investigated. Standard and sample solutions flow along a bunch of cotton thread treated with sodium hydroxide via microfluidic behaviors without external pumping. The analyte solution reacts with the reagents that have been immobilized on the paper strip fixed at the end of the cotton bunch. The developed platforms were used for the assays of total phenolic content and antioxidant capacity by employing Folin-Ciocalteu and 2, 2-diphenyl-1-picryhydrazyl (DPPH) respectively. Simple detection can be made by employing a mobile phone camera (iPhone 4S) with Image J or Photoshop for image processing and evaluation. Gallic acid was used as a reference standard in this work, as its polyphenol structures can be found in many plants. The total phenolic content is expressed as gallic acid equivalents (GAE) (mg/g material). Inhibition capacity is calculated by the equation: % I = [(I o - I s )/ I o ] × 100, where I s is the relative magenta intensity (CMYK mode) of sample, and I o the relative magenta intensity of DPPH•. IC 50 inhibition can be estimated from the graph and can be used for the antioxidant capacity consideration. Applications to the assay green tea samples were demonstrated. The total phenolic contents in the green tea samples were found to be 48-105mg/g, with %RSD of less than 10 for that of higher 50 GAE mg/g and IC 50 values of the samples studied were 25-50mg/L. The results obtained by the developed methods agree with that of the standard methods. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
2016-02-01
Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with four PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost-effectively implement with their own staffs in the normal course of housing operations at the time whenmore » units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing, and measures that improve equipment efficiency. ARIES documented implementation in 18 housing units. Reductions in average air leakage were 16 percent and duct leakage reductions averaged 23 percent. Total source energy consumption savings due to implemented measures was estimated at 3-10 percent based on BEopt modeling with a simple payback of 1.6 to 2.5 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.« less
Islip Housing Authority Energy Efficiency Turnover Protocols, Islip, New York (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2014-08-01
More than 1 million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 PHAs across the country indicated that there is a high level of interest in developing low cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations atmore » the time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation in ten housing units. Reductions in average air leakage were 16-20% and duct leakage reductions averaged 38%. Total source energy consumption savings was estimated at 6-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of unit per year nationally.« less
NASA Astrophysics Data System (ADS)
Humayun, Q.; Hashim, U.; Ruzaidi, C. M.; Noriman, N. Z.
2017-03-01
The fabrication and characterization of sensitive and selective fluids delivery system for the application of nano laboratory on a single chip is a challenging task till to date. This paper is one of the initial attempt to resolve this challenging task by using a simple, cost effective and reproductive technique for pattering a microchannel structures on SU-8 resist. The objective of the research is to design, fabricate and characterize polydimethylsiloxane (PDMS) microchannel. The proposed device mask was designed initially by using AutoCAD software and then the designed was transferred to transparency sheet and to commercial chrome mask for better photo masking process. The standard photolithography process coupled with wet chemical etching process was used for the fabrication of proposed microchannel. This is a low cost fabrication technique for the formation of microchannel structure at resist. The fabrication process start from microchannel formation and then the structure was transformed to PDMS substrate, the microchannel structure was cured from mold and then the cured mold was bonded with the glass substrate by plasma oxidation bonding process. The surface morphology was characterized by high power microscope (HPM) and the structure was characterized by Hawk 3 D surface nanoprofiler. The next part of the research will be focus onto device testing and validation by using real biological samples by the implementation of a simple manual injection technique.
Zhu, Xing; He, Bin; Zhao, Changwen; Fan, Rong; Zhang, Lihua; Wang, Guan; Ma, Yuhong; Yang, Wantai
2016-01-01
The main limitation preventing the use of enzymatic cellulosic ethanol in industrial production is its higher cost which is mainly due to the elevated price of β-glucosidase (BG). Herein, we report on a simple strategy for the in-situ encapsulation of BG for repeated cellulosic ethanol production. In this strategy, BG was net-immobilized into a poly(ethylene glycol) (PEG) net-cloth layer on a PP nonwoven fabric by way of the visible light-induced surface controlled/living graft cross-linking polymerization. The visible light and mild reaction conditions could ensure the activity retention of BG during immobilization, while the non-swelling uniform net-mesh formed by living cross-linking polymerization could prevent the leakage of BG effectively (at the immobilization rate of more than 98.6% and the leakage rate of only 0.4%). When the BG-loaded fabric was used in combination with free cellulase (CEL), the results of the catalytic reaction demonstrated that these BG-loaded fabrics could not only give a 40% increase in cellulose conversions but also be reused for more than fifteen batches without losing the activity. These BG-loaded fabrics with characteristics including easy separation, excellent operation stability, a low cost of the polymeric matrix and a simple fabrication process are particularly interesting for a future bio-fuel production strategy. PMID:27009788
Public Housing: A Tailored Approach to Energy Retrofits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dentz, J.; Conlin, F.; Podorson, D.
2016-02-18
Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with four PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost-effectively implement with their own staffs in the normal course of housing operations at the time whenmore » units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing, and measures that improve equipment efficiency. ARIES documented implementation in 18 housing units. Reductions in average air leakage were 16% and duct leakage reductions averaged 23%. Total source energy consumption savings due to implemented measures was estimated at 3-10% based on BEopt modeling with a simple payback of 1.6 to 2.5 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.« less
NASA Astrophysics Data System (ADS)
Zhu, Xing; He, Bin; Zhao, Changwen; Fan, Rong; Zhang, Lihua; Wang, Guan; Ma, Yuhong; Yang, Wantai
2016-03-01
The main limitation preventing the use of enzymatic cellulosic ethanol in industrial production is its higher cost which is mainly due to the elevated price of β-glucosidase (BG). Herein, we report on a simple strategy for the in-situ encapsulation of BG for repeated cellulosic ethanol production. In this strategy, BG was net-immobilized into a poly(ethylene glycol) (PEG) net-cloth layer on a PP nonwoven fabric by way of the visible light-induced surface controlled/living graft cross-linking polymerization. The visible light and mild reaction conditions could ensure the activity retention of BG during immobilization, while the non-swelling uniform net-mesh formed by living cross-linking polymerization could prevent the leakage of BG effectively (at the immobilization rate of more than 98.6% and the leakage rate of only 0.4%). When the BG-loaded fabric was used in combination with free cellulase (CEL), the results of the catalytic reaction demonstrated that these BG-loaded fabrics could not only give a 40% increase in cellulose conversions but also be reused for more than fifteen batches without losing the activity. These BG-loaded fabrics with characteristics including easy separation, excellent operation stability, a low cost of the polymeric matrix and a simple fabrication process are particularly interesting for a future bio-fuel production strategy.
Avery, Anthony J; Rodgers, Sarah; Cantrill, Judith A; Armstrong, Sarah; Elliott, Rachel; Howard, Rachel; Kendrick, Denise; Morris, Caroline J; Murray, Scott A; Prescott, Robin J; Cresswell, Kathrin; Sheikh, Aziz
2009-01-01
Background Medication errors are an important cause of morbidity and mortality in primary care. The aims of this study are to determine the effectiveness, cost effectiveness and acceptability of a pharmacist-led information-technology-based complex intervention compared with simple feedback in reducing proportions of patients at risk from potentially hazardous prescribing and medicines management in general (family) practice. Methods Research subject group: "At-risk" patients registered with computerised general practices in two geographical regions in England. Design: Parallel group pragmatic cluster randomised trial. Interventions: Practices will be randomised to either: (i) Computer-generated feedback; or (ii) Pharmacist-led intervention comprising of computer-generated feedback, educational outreach and dedicated support. Primary outcome measures: The proportion of patients in each practice at six and 12 months post intervention: - with a computer-recorded history of peptic ulcer being prescribed non-selective non-steroidal anti-inflammatory drugs - with a computer-recorded diagnosis of asthma being prescribed beta-blockers - aged 75 years and older receiving long-term prescriptions for angiotensin converting enzyme inhibitors or loop diuretics without a recorded assessment of renal function and electrolytes in the preceding 15 months. Secondary outcome measures; These relate to a number of other examples of potentially hazardous prescribing and medicines management. Economic analysis: An economic evaluation will be done of the cost per error avoided, from the perspective of the UK National Health Service (NHS), comparing the pharmacist-led intervention with simple feedback. Qualitative analysis: A qualitative study will be conducted to explore the views and experiences of health care professionals and NHS managers concerning the interventions, and investigate possible reasons why the interventions prove effective, or conversely prove ineffective. Sample size: 34 practices in each of the two treatment arms would provide at least 80% power (two-tailed alpha of 0.05) to demonstrate a 50% reduction in error rates for each of the three primary outcome measures in the pharmacist-led intervention arm compared with a 11% reduction in the simple feedback arm. Discussion At the time of submission of this article, 72 general practices have been recruited (36 in each arm of the trial) and the interventions have been delivered. Analysis has not yet been undertaken. Trial registration Current controlled trials ISRCTN21785299 PMID:19409095
Avery, Anthony J; Rodgers, Sarah; Cantrill, Judith A; Armstrong, Sarah; Elliott, Rachel; Howard, Rachel; Kendrick, Denise; Morris, Caroline J; Murray, Scott A; Prescott, Robin J; Cresswell, Kathrin; Sheikh, Aziz
2009-05-01
Medication errors are an important cause of morbidity and mortality in primary care. The aims of this study are to determine the effectiveness, cost effectiveness and acceptability of a pharmacist-led information-technology-based complex intervention compared with simple feedback in reducing proportions of patients at risk from potentially hazardous prescribing and medicines management in general (family) practice. RESEARCH SUBJECT GROUP: "At-risk" patients registered with computerised general practices in two geographical regions in England. Parallel group pragmatic cluster randomised trial. Practices will be randomised to either: (i) Computer-generated feedback; or (ii) Pharmacist-led intervention comprising of computer-generated feedback, educational outreach and dedicated support. The proportion of patients in each practice at six and 12 months post intervention: - with a computer-recorded history of peptic ulcer being prescribed non-selective non-steroidal anti-inflammatory drugs; - with a computer-recorded diagnosis of asthma being prescribed beta-blockers; - aged 75 years and older receiving long-term prescriptions for angiotensin converting enzyme inhibitors or loop diuretics without a recorded assessment of renal function and electrolytes in the preceding 15 months. SECONDARY OUTCOME MEASURES; These relate to a number of other examples of potentially hazardous prescribing and medicines management. An economic evaluation will be done of the cost per error avoided, from the perspective of the UK National Health Service (NHS), comparing the pharmacist-led intervention with simple feedback. QUALITATIVE ANALYSIS: A qualitative study will be conducted to explore the views and experiences of health care professionals and NHS managers concerning the interventions, and investigate possible reasons why the interventions prove effective, or conversely prove ineffective. 34 practices in each of the two treatment arms would provide at least 80% power (two-tailed alpha of 0.05) to demonstrate a 50% reduction in error rates for each of the three primary outcome measures in the pharmacist-led intervention arm compared with a 11% reduction in the simple feedback arm. At the time of submission of this article, 72 general practices have been recruited (36 in each arm of the trial) and the interventions have been delivered. Analysis has not yet been undertaken.
Successful and stable orthodontic camouflage of a mandibular asymmetry with sliding jigs.
Oliveira, Dauro Douglas; Oliveira, Bruno Franco de; Mordente, Carolina Morsani; Godoy, Gabriela Martins; Soares, Rodrigo Villamarim; Seraidarian, Paulo Isaías
2018-03-12
The purpose of this paper is to present and discuss a simple and low-cost clinical approach to correct an asymmetric skeletal Class III combined to an extensive dental open bite that significantly compromised the occlusal function and smile aesthetics of an adult male patient. The patient did not accept the idealistic surgical-orthodontic treatment option, neither the use of temporary anchorage devices to facilitate the camouflage of the asymmetrical skeletal Class III/open bite. Therefore, a very simple and inexpensive biomechanical approach using sliding jigs in the mandibular arch was implemented as the compensatory treatment of the malocclusion. Although minor enhancements in facial aesthetics were obtained, the occlusal function and dental aesthetics were significantly improved. Furthermore, the patient was very satisfied with his new smile appearance. Some advantages of this treatment option included the small invasiveness and the remarkably low financial costs involved. Moreover, the final results fulfilled all realistic treatment objectives and the patient's expectations. Results remained stable 5 years post-treatment demonstrating that excellent results can be obtained when simple and low cost, but well-controlled mechanics are conducted.
The Simple Lamb Wave Analysis to Characterize Concrete Wide Beams by the Practical MASW Test
Lee, Young Hak; Oh, Taekeun
2016-01-01
In recent years, the Lamb wave analysis by the multi-channel analysis of surface waves (MASW) for concrete structures has been an effective nondestructive evaluation, such as the condition assessment and dimension identification by the elastic wave velocities and their reflections from boundaries. This study proposes an effective Lamb wave analysis by the practical application of MASW to concrete wide beams in an easy and simple manner in order to identify the dimension and elastic wave velocity (R-wave) for the condition assessment (e.g., the estimation of elastic properties). This is done by identifying the zero-order antisymmetric (A0) and first-order symmetric (S1) modes among multimodal Lamb waves. The MASW data were collected on eight concrete wide beams and compared to the actual depth and to the pressure (P-) wave velocities collected for the same specimen. Information is extracted from multimodal Lamb wave dispersion curves to obtain the elastic stiffness parameters and the thickness of the concrete structures. Due to the simple and cost-effective procedure associated with the MASW processing technique, the characteristics of several fundamental modes in the experimental Lamb wave dispersion curves could be measured. Available reference data are in good agreement with the parameters that were determined by our analysis scheme. PMID:28773562
NASA Astrophysics Data System (ADS)
Kuo, Cynthia; Walker, Jesse; Perrig, Adrian
Bluetooth Simple Pairing and Wi-Fi Protected Setup specify mechanisms for exchanging authentication credentials in wireless networks. Both Simple Pairing and Protected Setup support multiple setup mechanisms, which increases security risks and hurts the user experience. To improve the security and usability of these specifications, we suggest defining a common baseline for hardware features and a consistent, interoperable user experience across devices.
ERIC Educational Resources Information Center
Namwong, Pithakpong; Jarujamrus, Purim; Amatatongchai, Maliwan; Chairam, Sanoe
2018-01-01
In this article, a low-cost, simple, and rapid fabrication of paper-based analytical devices (PADs) using a wax screen-printing method is reported here. The acid-base reaction is implemented in the simple PADs to demonstrate to students the chemistry concept of a limiting reagent. When a fixed concentration of base reacts with a gradually…
Prosser, Helen; Walley, Tom
2005-03-01
With prescribing expenditure rising and evidence of prescribing costs variation, general practitioners (GPs) in the UK are under increasing pressure to contain spending. The introduction of cash-limited, unified budgets and increased monitoring of prescribing within Primary Care Organizations (PCO) are intended to increase efficiency and enhance GPs financial responsibility. Whilst GPs regularly receive data on the costs of their prescribing and also performance against a set prescribing budget, little is known about the extent to which GPs take cost into account in their prescribing decisions. This study undertook a qualitative exploration of the attitudes of various stakeholders on the relative importance and influence of cost on general practice prescribing. In order to explore a plurality of perspectives, data were obtained from focus groups and a series of individual semi-structured interviews with GPs and key PCO stakeholders. The data suggest that although almost all GPs believed costs should be taken into account when prescribing, there was great variation in the extent to which this was applied and to how sensitive GPs were to costs. Cost was secondary to clinical effectiveness and safety, whilst individual patient need was emphasized above other forms of rationality or notions of opportunity costs. Conflict was apparent between a PCO policy of cost-containment and GPs' resistance to cost-cutting. GPs largely applied simple cost-minimization while cost-consideration was undermined by contextual factors. Implications for research and policy are discussed.
Suárez-Llanos, José Pablo; Benítez-Brito, Néstor; Vallejo-Torres, Laura; Delgado-Brito, Irina; Rosat-Rodrigo, Adriá; Hernández-Carballo, Carolina; Ramallo-Fariña, Yolanda; Pereyra-García-Castro, Francisca; Carlos-Romero, Juan; Felipe-Pérez, Nieves; García-Niebla, Jennifer; Calderón-Ledezma, Eduardo Mauricio; González-Melián, Teresa de Jesús; Llorente-Gómez de Segura, Ignacio; Barrera-Gómez, Manuel Ángel
2017-04-20
Malnutrition is highly prevalent in hospitalized patients and results in a worsened clinical course as well as an increased length of stay, mortality, and costs. Therefore, simple nutrition screening systems, such as CIPA (control of food intake, protein, anthropometry), may be implemented to facilitate the patient's recovery process. The aim of this study is to evaluate the effectiveness and cost-effectiveness of implementing such screening tool in a tertiary hospital, consistent with the lack of similar, published studies on any hospital nutrition screening system. The present study is carried out as an open, controlled, randomized study on patients that were admitted to the Internal Medicine and the General and Digestive Surgery ward; the patients were randomized to either a control or an intervention group (n = 824, thereof 412 patients in each of the two study arms). The control group underwent usual inpatient clinical care, while the intervention group was evaluated with the CIPA screening tool for early detection of malnutrition and treated accordingly. CIPA nutrition screening was performed upon hospital admission and classified positive when at least one of the following parameters was met: 72 h food intake control < 50%, serum albumin < 3 g/dL, body mass index < 18.5 kg/m 2 (or mid-upper arm circumference ≤ 22.5 cm). In this case, the doctor decided on whether or not providing nutrition support. The following variables will be evaluated: hospital length of stay (primary endpoint), mortality, 3-month readmission, and in-hospital complications. Likewise, the quality of life questionnaires EQ-5D-5 L are being collected for all patients at hospital admission, discharge, and 3 months post-discharge. Analysis of cost-effectiveness will be performed by measuring effectiveness in terms of quality-adjusted life years (QALYs). The cost per patient will be established by identifying health care resource utilization; cost-effectiveness will be determined through the incremental cost-effectiveness ratio (ICER). We will calculate the incremental cost per QALY gained with respect to the intervention. This ongoing trial aims to evaluate the cost-effectiveness of implementing the malnutrition screening tool CIPA in a tertiary hospital. Clinical Trial.gov ( NCT02721706 ). First receivevd: March 1, 2016 Last updated: April 8, 2017 Last verified: April 2017.
A decision-making framework for total ownership cost management of complex systems: A Delphi study
NASA Astrophysics Data System (ADS)
King, Russel J.
This qualitative study, using a modified Delphi method, was conducted to develop a decision-making framework for the total ownership cost management of complex systems in the aerospace industry. The primary focus of total ownership cost is to look beyond the purchase price when evaluating complex system life cycle alternatives. A thorough literature review and the opinions of a group of qualified experts resulted in a compilation of total ownership cost best practices, cost drivers, key performance factors, applicable assessment methods, practitioner credentials and potential barriers to effective implementation. The expert panel provided responses to the study questions using a 5-point Likert-type scale. Data were analyzed and provided to the panel members for review and discussion with the intent to achieve group consensus. As a result of the study, the experts agreed that a total ownership cost analysis should (a) be as simple as possible using historical data; (b) establish cost targets, metrics, and penalties early in the program; (c) monitor the targets throughout the product lifecycle and revise them as applicable historical data becomes available; and (d) directly link total ownership cost elements with other success factors during program development. The resultant study framework provides the business leader with incentives and methods to develop and implement strategies for controlling and reducing total ownership cost over the entire product life cycle when balancing cost, schedule, and performance decisions.
Darmon, Nicole; Ferguson, Elaine L; Briend, André
2002-12-01
Economic constraints may contribute to the unhealthy food choices observed among low socioeconomic groups in industrialized countries. The objective of the present study was to predict the food choices a rational individual would make to reduce his or her food budget, while retaining a diet as close as possible to the average population diet. Isoenergetic diets were modeled by linear programming. To ensure these diets were consistent with habitual food consumption patterns, departure from the average French diet was minimized and constraints that limited portion size and the amount of energy from food groups were introduced into the models. A cost constraint was introduced and progressively strengthened to assess the effect of cost on the selection of foods by the program. Strengthening the cost constraint reduced the proportion of energy contributed by fruits and vegetables, meat and dairy products and increased the proportion from cereals, sweets and added fats, a pattern similar to that observed among low socioeconomic groups. This decreased the nutritional quality of modeled diets, notably the lowest cost linear programming diets had lower vitamin C and beta-carotene densities than the mean French adult diet (i.e., <25% and 10% of the mean density, respectively). These results indicate that a simple cost constraint can decrease the nutrient densities of diets and influence food selection in ways that reproduce the food intake patterns observed among low socioeconomic groups. They suggest that economic measures will be needed to effectively improve the nutritional quality of diets consumed by these populations.
A simple ion implanter for material modifications in agriculture and gemmology
NASA Astrophysics Data System (ADS)
Singkarat, S.; Wijaikhum, A.; Suwannakachorn, D.; Tippawan, U.; Intarasiri, S.; Bootkul, D.; Phanchaisri, B.; Techarung, J.; Rhodes, M. W.; Suwankosum, R.; Rattanarin, S.; Yu, L. D.
2015-12-01
In our efforts in developing ion beam technology for novel applications in biology and gemmology, an economic simple compact ion implanter especially for the purpose was constructed. The designing of the machine was aimed at providing our users with a simple, economic, user friendly, convenient and easily operateable ion implanter for ion implantation of biological living materials and gemstones for biotechnological applications and modification of gemstones, which would eventually contribute to the national agriculture, biomedicine and gem-industry developments. The machine was in a vertical setup so that the samples could be placed horizontally and even without fixing; in a non-mass-analyzing ion implanter style using mixed molecular and atomic nitrogen (N) ions so that material modifications could be more effective; equipped with a focusing/defocusing lens and an X-Y beam scanner so that a broad beam could be possible; and also equipped with a relatively small target chamber so that living biological samples could survive from the vacuum period during ion implantation. To save equipment materials and costs, most of the components of the machine were taken from decommissioned ion beam facilities. The maximum accelerating voltage of the accelerator was 100 kV, ideally necessary for crop mutation induction and gem modification by ion beams from our experience. N-ion implantation of local rice seeds and cut gemstones was carried out. Various phenotype changes of grown rice from the ion-implanted seeds and improvements in gemmological quality of the ion-bombarded gemstones were observed. The success in development of such a low-cost and simple-structured ion implanter provides developing countries with a model of utilizing our limited resources to develop novel accelerator-based technologies and applications.
A comparison of 8.415-, 32.0- and 565646-GHz deep space telemetry links
NASA Technical Reports Server (NTRS)
Dickinson, R. M.
1985-01-01
An economic and performance comparison is made of spacecraft telecommunication links at 8.415, 32.0, and 565646 GHz (0.53-micron wavelength) for the return of 3.43 x 10 to the 11th power bits from a Saturn Orbiter/Titan Probe mission in year 2000. Technical performance and costs for both ends of the links are included. Spacecraft antenna or telescope efficiencies, pointing losses, ground-based or Earth-orbiting relay terminals efficiencies, noise temperatures, recurring and nonrecurring engineering, and maintenance and operations costs are modeled. Weather effects, dc-to-RF or laser power conversion efficiencies, gravity and other environment distortions gain reductions, and the cost of pointing and tracking are analyzed. The effort is focused primarily on the microwave frequency links. There are large uncertainties in the cost results, but conclusions indicate that for a mid-1990's launch, the Ka-band system is as cost effective as X-band. The Ka-band system has a data rate advantage as compared to the X-band system for the same dc power input to the spacecraft. The magnitude of the advantage is a complex function of the weather at the DSN stations and the elevation angle of the ground antenna. A simple numerical comparison of the advantage is difficult and curves are provided. The optical frequency link is more costly based on the launch-to-orbit costs for the orbiting terminal. A more detailed study of the optical system is recommended to quantify astrometric tracking benefits and improve the accuracy of the cost estimate.
Economic implications of resistance to antimalarial drugs.
Phillips, M; Phillips-Howard, P A
1996-09-01
The widespread evolution of drug resistance in malarial parasites has seriously hampered efforts to control this debilitating disease. Chloroquine, the mainstay of malaria treatment for many decades, is now proving largely ineffective in many parts of the world, particularly against the most severe form of malaria--falciparum. Alternative drugs have been developed, but they are frequently less safe and are all between 50 and 700% more expensive than chloroquine. Choice of drug clearly has important budgetary implications and national malaria control programmes need to weigh up the costs and benefits in deciding whether to change to more effective but more expensive drugs. The growth in drug resistance also has implications for the choice of diagnostic tool. Clinical diagnosis of malaria is relatively cheap, but less specific than some technological approaches. As more expensive drugs are employed, the cost of wasted treatment on suspected cases who do not in fact have malaria rises and the more worthwhile it becomes to invest in more specific diagnostic techniques. This paper presents an economic framework for analysing the various malaria drug and diagnostic tool options available. It discusses the nature of the key factors that need to be considered when making choices of malaria treatment (including treatment costs, drug resistance, the costs of treatment failure and compliance) and diagnosis (including diagnosis cost and accuracy, and the often overlooked costs associated with delayed treatment), and uses some simple equations to illustrate the impact of these on the relative cost effectiveness of the alternatives being considered. On the basis of some simplifying assumptions and illustrative calculations, it appears that in many countries more effective drugs and more specific and rapid diagnostic approaches will be worth adopting even although they imply additional expense.
Self-Assembled Carbon-Polyoxometalate Composites for Electrochemical Capacitors
NASA Astrophysics Data System (ADS)
Genovese, Matthew
The development of high performance yet cost effective energy storage devices is critical for enabling the growth of important emerging sectors from the internet of things to grid integration of renewable energy. Material costs are by far the largest contributor to the overall cost of energy storage devices and thus research into cost effective energy storage materials will play an important role in developing technology to meet real world storage demands. In this thesis, low cost high performance composite electrode materials for supercapacitors (SCs) have been developed through the surface modification of electrochemically double layer capacitive (EDLC) carbon substrates with pseudocapacitive Polyoxometalates (POMs). Significant fundamental contributions have been made to the understanding of all components of the composite electrode including the POM active layer, cation linker, and carbon substrate. The interaction of different POM chemistries in solution has been studied to elucidate the novel ways in which these molecules combine and the mechanism underlying this combination. A more thorough understanding regarding the cation linker's role in electrode fabrication has been developed through examining the linker properties which most strongly affect electrode performance. The development of porosity in biomass derived carbon materials has also been examined leading to important insights regarding the effect of substrate porosity on POM modification and electrochemical properties. These fundamental contributions enabled the design and performance optimization of POM-carbon composite SC electrodes. Understanding how POMs combine in solution, allowed for the development of mixed POM molecular coatings with tunable electrochemical properties. These molecular coatings were used to modify low cost biomass derived carbon substrates that had been structurally optimized to accommodate POM molecules. The resulting electrode composites utilizing low cost materials fabricated through simple scalable techniques demonstrated (i) high capacitance (361 F g-1), (ii) close to ideal pseudocapacitive behavior, (iii) stable cycling, and (iv) good rate performance.
Low-Cost Propellant Launch to Earth Orbit from a Tethered Balloon
NASA Technical Reports Server (NTRS)
Wilcox, Brian H.
2006-01-01
Propellant will be more than 85% of the mass that needs to be lofted into Low Earth Orbit (LEO) in the planned program of Exploration of the Moon, Mars, and beyond. This paper describes a possible means for launching thousands of tons of propellant per year into LEO at a cost 15 to 30 times less than the current launch cost per kilogram. The basic idea is to mass-produce very simple, small and relatively low-performance rockets at a cost per kilogram comparable to automobiles, instead of the 25X greater cost that is customary for current launch vehicles that are produced in small quantities and which are manufactured with performance near the limits of what is possible. These small, simple rockets can reach orbit because they are launched above 95% of the atmosphere, where the drag losses even on a small rocket are acceptable, and because they can be launched nearly horizontally with very simple guidance based primarily on spin-stabilization. Launching above most of the atmosphere is accomplished by winching the rocket up a tether to a balloon. A fuel depot in equatorial orbit passes over the launch site on every orbit (approximately every 90 minutes). One or more rockets can be launched each time the fuel depot passes overhead, so the launch rate can be any multiple of 6000 small rockets per year, a number that is sufficient to reap the benefits of mass production.
[Extraction of artemisinin and synthesis of its derivates artesunate and artemether].
Chekem, L; Wierucki, S
2006-12-01
Artemisinin is extracted from Artemisia annua, a shrub also known as sweet wormwood that was used in traditional medicine in Asia for more than 1500 years. Recent studies in numerous malarious zones have demonstrated the effectiveness of artemisinin and have reported no evidence of the resistance now associated with almost all other antimalarials on the market. Despite its remarkable activity, artermisinin is not accessible to many patients due to high cost. This situation confronts all players in the fight against malaria with the urgent need to develop a simple process to produce massive supplies of artemisinin and its derivative at an affordable price. The purpose of the study described here was to develop a simple, cost-effective method that could be used by all professionals to extract artemisinin and transform it into artesunate or artemether. Artemisinin was extracted with dichloromethane and purified on the basis of variations in polarity and in the hydrophile/lipophile balance of solvents. Transformation into artesunate was a two-step process involving reduction to dihydroartemisinin using diisobutylaluminium hydride (DIBAL) followed by esterification using succinic anhydride. Artemether was obtained from dihydroartemisinin using boron trifluoride. Extraction using dichloromethane presents several advantages. Since dichloromethane is not explosive it can be safely transported and used for extraction on farms where Artemisia annua is grown. Evaporation and recovery of dichloromethane is relatively easy so that it can be re-used. These advantages result in a significant decrease in purchasing and shipping costs. Extraction on the farm eliminates the expense and facilities that would otherwise be required to transport and store leaves at the laboratory (250 kg of leaves yield 4 to 5 kg of raw artemisinin extract that yields approximately 1 kg of pure artemisinin). The low-cost process described here is feasible for any pharmaceutical laboratory including those in developing countries.
Time-of-Flight Measurement of the Speed of Sound in Water
ERIC Educational Resources Information Center
Ganci, Salvatore
2016-01-01
A simple setup is designed to investigate a "time-of-flight" measurement of the speed of sound in water. This experiment only requires low cost components and is also very simple to understand by students. It could be easily used as a demonstration experiment.
MODIFICATIONS TO REDUCE DRAG OUT AT A PRINTED CIRCUIT BOARD MANUFACTURER
This MnTAP/EPA Waste Reduction Innovative Technology Evaluation project at Micom, Inc., demonstrated the waste reducing capability of two simple rinsing modifications on an etchant and an electroless copper process. he simple, tow (or no) cost, low technology changes that were ma...
Morselli, Paolo Giovanni; Micai, Alessandro; Giorgini, Federico Armando
2016-08-01
The "Lull pgm system" is a closed system for purifying harvested fat. It processes the collected tissue safely without any additional cost. The system was conceived by referring to the targets described in the literature with the aim of creating a simple system that guarantees a high standard of purification and requires minimal equipment that is available in every operating room. Cost must be always considered: even the most prosperous hospitals must keep within tight annual budgets. "Lull" can be used instead of expensive devices or disposable kits, without substantially increasing the operating time. The system has been used in clinical practice for many plastic reconstructive procedures and has obtained positive results and patient satisfaction, and no contraindications or disadvantages have been observed.
The cost-effectiveness of screening for hereditary hemochromatosis in Germany: a remodeling study.
Rogowski, Wolf H
2009-01-01
Genetic tests for hereditary hemochromatosis (HH) are currently included in the German ambulatory care reimbursement scheme but only for symptomatic individuals and the offspring of HH patients. This study synthesizes the most current evidence to examine whether screening in the broader population is cost-effective and to identify the best choice of initial and follow-up screening tests. A probabilistic decision-analytic model was constructed to calculate cost per life year gained (LYG) for HH screening among male Caucasians aged 30. Three strategies were considered in both the general population and male offspring of HH patients: phenotypic (transferrin saturation, TS), genotypic (C282Y mutation), and sequential (genotype if TS is elevated) screening. The incremental cost-effectiveness of sequential screening among male offspring, sequential population-wide screening, and genotypic screening is 41000, 124000, and 161000 Eero/LYG, respectively. All other strategies were subject to simple or extended dominance. The results are subject to high uncertainty. The most influential parameters in the deterministic one-way sensitivity analysis are discounting of life years gained and the adherence of patients to preventive phlebotomy. The current German policy of only screening at-risk individuals is consistent with health economic decision making based on typically accepted thresholds. However, conducting the DNA test after the first elevated TS result is more cost-effective than waiting for a second TS result as recommended by the German guidelines. Further empirical work regarding adherence to long-term prevention recommendations and explicit and well-justified guidance for the choice of discount rates in German economic evaluation are needed.
Araya, Ricardo; Flynn, Terry; Rojas, Graciela; Fritsch, Rosemarie; Simon, Greg
2006-08-01
The authors compared the incremental cost-effectiveness of a stepped-care, multicomponent program with usual care for the treatment of depressed women in primary care in Santiago, Chile. A cost-effectiveness study was conducted of a previous randomized controlled trial involving 240 eligible women with DSM-IV major depression who were selected from a consecutive sample of adult women attending primary care clinics. The patients were randomly allocated to usual care or a multicomponent stepped-care program led by a nonmedical health care worker. Depression-free days and health care costs derived from local sources were assessed after 3 and 6 months. A health service perspective was used in the economic analysis. Complete data were determined for 80% of the randomly assigned patients. After we adjusted for initial severity, women receiving the stepped-care program had a mean of 50 additional depression-free days over 6 months relative to patients allocated to usual care. The stepped-care program was marginally more expensive than usual care (an extra 216 Chilean pesos per depression-free day). There was a 90% probability that the incremental cost of obtaining an extra depression-free day with the intervention would not exceed 300 pesos (1.04 US dollars). The stepped-care program was significantly more effective and marginally more expensive than usual care for the treatment of depressed women in primary care. Small investments to improve depression appear to yield larger gains in poorer environments. Simple and inexpensive treatment programs tested in developing countries might provide good study models for developed countries.
Mehta, Mohina; Ram, Raja; Bhattacharya, Amita
2014-07-01
The two commercially important apple rootstocks i.e., MM106 and B9 were micropropagated using a liquid culture system. Three different strengths of 0.8% agar solidified PGR free basal MS medium were first tested to optimize the culture media for both the rootstocks. Full strength medium (MS0) supported maximum in vitro growth, multiplication, rooting and survival under field conditions as opposed to quarter and half strength media. When three different volumes of liquid MS0 were tested, highest in vitro growth, multiplication, rooting and also survival under field conditions were achieved in 20 mL liquid MS0. The cost of one litre of liquid medium was also reduced by 8 times to Rs. 6.29 as compared to solid medium. The cost of 20 mL medium was further reduced to Rs. 0.125.
In-plane cost-effective magnetically actuated valve for microfluidic applications
NASA Astrophysics Data System (ADS)
Pugliese, Marco; Ferrara, Francesco; Bramanti, Alessandro Paolo; Gigli, Giuseppe; Maiorano, Vincenzo
2017-04-01
We present a new in-plane magnetically actuated microfluidic valve. Its simple design includes a circular area joining two channels lying on the same plane. The area is parted by a septum lying on and adhering to a magneto-active polymeric ‘floor’ membrane, keeping the channels normally separated (valve closed). Under the action of a magnetic field, the membrane collapses, letting the liquid flow below the septum (valve open). The valve was extensively characterized experimentally, and modeled and optimized theoretically. The growing interest in lab on chips, especially for diagnostics and precision medicine, is driving researchers towards smart, efficient and low cost solutions to the management of biological samples. In this context, the valve developed in this work represents a useful building-block for microfluidic applications requiring precise flow control, its main features being easy and rapid manufacturing, biocompatibility and low cost.
Crowdsourcing Stream Stage in Data Scarce Regions: Applications of CrowdHydrology
NASA Astrophysics Data System (ADS)
Lowry, C.; Fienen, M. N.
2013-12-01
Crowdsourced data collection using citizen scientists and mobile phones is a promising way to collect supplemental information in data scarce or remote regions. The research presented here explore the possibilities and pitfalls of crowdsourcing hydrologic data via mobile phone text messaging through the example of CrowdHydrology, a distributed network of over 40 stream gages in four states. Signage at the CrowdHydrology gages ask citizen scientists to answer to a simple question via text message: 'What is the water height?'. While these data in no way replace more traditional measurements of stream stage, they do provide low cost supplemental measurements in data scarce regions. Results demonstrate the accuracy of crowdsourced data and provide insight for successful future crowdsourced data collection efforts. A less recognized benefit is that even in data rich areas, crowdsourced data collection is a cost-effective way to perform quality assurance on more sophisticated, and costly, data collection efforts.
Analyzing costs of space debris mitigation methods
NASA Astrophysics Data System (ADS)
Wiedemann, C.; Krag, H.; Bendisch, J.; Sdunnus, H.
The steadily increasing number of space objects poses a considerable hazard to all kinds of spacecraft. To reduce the risks to future space missions different debris mitigation measures and spacecraft protection techniques have been investigated during the last years. However, the economic efficiency has not been considered yet in this context. This economical background is not always clear to satellite operators and the space industry. Current studies have the objective to evaluate the mission costs due to space debris in a business as usual (no mitigation) scenario compared to the missions costs considering debris mitigation. The aim i an estimation of thes time until the investment in debris mitigation will lead to an effective reduction of mission costs. This paper presents the results of investigations on the key problems of cost estimation for spacecraft and the influence of debris mitigation and shielding on cost. The shielding of a satellite can be an effective method to protect the spacecraft against debris impact. Mitigation strategies like the reduction of orbital lifetime and de- or re-orbit of non-operational satellites are methods to control the space debris environment. These methods result in an increase of costs. In a first step the overall costs of different types of unmanned satellites are analyzed. The key problem is, that it is not possible to provide a simple cost model that can be applied to all types of satellites. Unmanned spacecraft differ very much in mission, complexity of design, payload and operational lifetime. It is important to classify relevant cost parameters and investigate their influence on the respective mission. The theory of empirical cost estimation and existing cost models are discussed. A selected cost model is simplified and generalized for an application on all operational satellites. In a next step the influence of space debris on cost is treated, if the implementation of mitigation strategies is considered.
A simple integrated assessment approach to global change simulation and evaluation
NASA Astrophysics Data System (ADS)
Ogutu, Keroboto; D'Andrea, Fabio; Ghil, Michael
2016-04-01
We formulate and study the Coupled Climate-Economy-Biosphere (CoCEB) model, which constitutes the basis of our idealized integrated assessment approach to simulating and evaluating global change. CoCEB is composed of a physical climate module, based on Earth's energy balance, and an economy module that uses endogenous economic growth with physical and human capital accumulation. A biosphere model is likewise under study and will be coupled to the existing two modules. We concentrate on the interactions between the two subsystems: the effect of climate on the economy, via damage functions, and the effect of the economy on climate, via a control of the greenhouse gas emissions. Simple functional forms of the relation between the two subsystems permit simple interpretations of the coupled effects. The CoCEB model is used to make hypotheses on the long-term effect of investment in emission abatement, and on the comparative efficacy of different approaches to abatement, in particular by investing in low carbon technology, in deforestation reduction or in carbon capture and storage (CCS). The CoCEB model is very flexible and transparent, and it allows one to easily formulate and compare different functional representations of climate change mitigation policies. Using different mitigation measures and their cost estimates, as found in the literature, one is able to compare these measures in a coherent way.
Kim, Bongseok; Kim, Sangdong; Lee, Jonghun
2018-01-01
We propose a novel discrete Fourier transform (DFT)-based direction of arrival (DOA) estimation by a virtual array extension using simple multiplications for frequency modulated continuous wave (FMCW) radar. DFT-based DOA estimation is usually employed in radar systems because it provides the advantage of low complexity for real-time signal processing. In order to enhance the resolution of DOA estimation or to decrease the missing detection probability, it is essential to have a considerable number of channel signals. However, due to constraints of space and cost, it is not easy to increase the number of channel signals. In order to address this issue, we increase the number of effective channel signals by generating virtual channel signals using simple multiplications of the given channel signals. The increase in channel signals allows the proposed scheme to detect DOA more accurately than the conventional scheme while using the same number of channel signals. Simulation results show that the proposed scheme achieves improved DOA estimation compared to the conventional DFT-based method. Furthermore, the effectiveness of the proposed scheme in a practical environment is verified through the experiment. PMID:29758016
Webcam camera as a detector for a simple lab-on-chip time based approach.
Wongwilai, Wasin; Lapanantnoppakhun, Somchai; Grudpan, Supara; Grudpan, Kate
2010-05-15
A modification of a webcam camera for use as a small and low cost detector was demonstrated with a simple lab-on-chip reactor. Real time continuous monitoring of the reaction zone could be done. Acid-base neutralization with phenolphthalein indicator was used as a model reaction. The fading of pink color of the indicator when the acidic solution diffused into the basic solution zone was recorded as the change of red, blue and green colors (%RBG.) The change was related to acid concentration. A low cost portable semi-automation analysis system was achieved.
A Simplified, Low-Cost Method for Polarized Light Microscopy
Maude, Richard J.; Buapetch, Wanchana; Silamut, Kamolrat
2009-01-01
Malaria pigment is an intracellular inclusion body that appears in blood and tissue specimens on microscopic examination and can help in establishing the diagnosis of malaria. In simple light microscopy, it can be difficult to discern from cellular background and artifacts. It has long been known that if polarized light microscopy is used, malaria pigment can be much easier to distinguish. However, this technique is rarely used because of the need for a relatively costly polarization microscope. We describe a simple and economical technique to convert any standard light microscope suitable for examination of malaria films into a polarization microscope. PMID:19861611
Dai, Yifan; Molazemhosseini, Alireza; Liu, Chung Chiun
2017-07-20
A simple in vitro biosensor for the detection of β-amyloid 42 in phosphate-buffered saline (PBS) and undiluted human serum was fabricated and tested based on our platform sensor technology. The bio-recognition mechanism of this biosensor was based on the effect of the interaction between antibody and antigen of β-amyloid 42 to the redox couple probe of K₄Fe(CN)₆ and K₃Fe(CN)₆. Differential pulse voltammetry (DPV) served as the transduction mechanism measuring the current output derived from the redox coupling reaction. The biosensor was a three-electrode electrochemical system, and the working and counter electrodes were 50 nm thin gold film deposited by a sputtering technique. The reference electrode was a thick-film printed Ag/AgCl electrode. Laser ablation technique was used to define the size and structure of the biosensor. Cost-effective roll-to-roll manufacturing process was employed in the fabrication of the biosensor, making it simple and relatively inexpensive. Self-assembled monolayers (SAM) of 3-Mercaptopropionic acid (MPA) was employed to covalently immobilize the thiol group on the gold working electrode. A carbodiimide conjugation approach using N -(3-dimethylaminopropyl)- N '-ethylcarbodiimide hydrochloride (EDC) and N -hydroxysuccinimide (NHS) was undertaken for cross-linking antibody of β-amyloid 42 to the carboxylic groups on one end of the MPA. The antibody concentration of β-amyloid 42 used was 18.75 µg/mL. The concentration range of β-amyloid 42 in this study was from 0.0675 µg/mL to 0.5 µg/mL for both PBS and undiluted human serum. DPV measurements showed excellent response in this antigen concentration range. Interference study of this biosensor was carried out in the presence of Tau protein antigen. Excellent specificity of this β-amyloid 42 biosensor was demonstrated without interference from other species, such as T-tau protein.
Goh, Wei Jiang; Zou, Shui; Ong, Wei Yi; Torta, Federico; Alexandra, Alvarez Fernandez; Schiffelers, Raymond M; Storm, Gert; Wang, Jiong-Wei; Czarny, Bertrand; Pastorin, Giorgia
2017-10-30
Cell Derived Nanovesicles (CDNs) have been developed from the rapidly expanding field of exosomes, representing a class of bioinspired Drug Delivery Systems (DDS). However, translation to clinical applications is limited by the low yield and multi-step approach in isolating naturally secreted exosomes. Here, we show the first demonstration of a simple and rapid production method of CDNs using spin cups via a cell shearing approach, which offers clear advantages in terms of yield and cost-effectiveness over both traditional exosomes isolation, and also existing CDNs fabrication techniques. The CDNs obtained were of a higher protein yield and showed similarities in terms of physical characterization, protein and lipid analysis to both exosomes and CDNs previously reported in the literature. In addition, we investigated the mechanisms of cellular uptake of CDNs in vitro and their biodistribution in an in vivo mouse tumour model. Colocalization of the CDNs at the tumour site in a cancer mouse model was demonstrated, highlighting the potential for CDNs as anti-cancer strategy. Taken together, the results suggest that CDNs could provide a cost-effective alternative to exosomes as an ideal drug nanocarrier.
Water Management Planning: A Case Study at Blue Grass Army Depot
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solana, Amy E.; Mcmordie, Katherine
2006-04-03
Executive Order 13123, Greening the Government Through Efficient Energy Management, mandates an aggressive policy for reducing potable water consumption at federal facilities. Implementation guid¬ance from the U.S. Department of Energy (DOE) set a requirement for each federal agency to “reduce potable water usage by implementing life cycle, cost-effective water efficiency programs that include a water management plan, and not less than four Federal Energy Management Program (FEMP) Best Manage¬ment Practices (BMPs).” The objective of this plan is to gain full compliance with Executive Order 13123 and associated DOE implementation guidance on behalf of Blue Grass Army Depot (BGAD), Richmond, Kentucky.more » In accordance with this plan, BGAD must: • Incorporate the plan as a component of the Installation energy conservation plan • Investigate the water savings potential and life-cycle cost effectiveness of the Operations and Maintenance (O&M) and retrofit/replacement options associated with the ten FEMP BMPs • Put into practice all applicable O&M options • Identify retrofit/replacement options appropriate for implementation (based upon calculation of the simple payback periods) • Establish a schedule for implementation of applicable and cost-effective retrofit/replacement options.« less
An IMS-Based Middleware Solution for Energy-Efficient and Cost-Effective Mobile Multimedia Services
NASA Astrophysics Data System (ADS)
Bellavista, Paolo; Corradi, Antonio; Foschini, Luca
Mobile multimedia services have recently become of extreme industrial relevance due to the advances in both wireless client devices and multimedia communications. That has motivated important standardization efforts, such as the IP Multimedia Subsystem (IMS) to support session control, mobility, and interoperability in all-IP next generation networks. Notwithstanding the central role of IMS in novel mobile multimedia, the potential of IMS-based service composition for the development of new classes of ready-to-use, energy-efficient, and cost-effective services is still widely unexplored. The paper proposes an original solution for the dynamic and standard-compliant redirection of incoming voice calls towards WiFi-equipped smart phones. The primary design guideline is to reduce energy consumption and service costs for the final user by automatically switching from the 3G to the WiFi infrastructure whenever possible. The proposal is fully compliant with the IMS standard and exploits the recently released IMS presence service to update device location and current communication opportunities. The reported experimental results point out that our solution, in a simple way and with full compliance with state-of-the-art industrially-accepted standards, can significantly increase battery lifetime without negative effects on call initiation delay.
Nishikiori, Nobuyuki; Van Weezenbeek, Catharina
2013-02-02
Despite the progress made in the past decade, tuberculosis (TB) control still faces significant challenges. In many countries with declining TB incidence, the disease tends to concentrate in vulnerable populations that often have limited access to health care. In light of the limitations of the current case-finding approach and the global urgency to improve case detection, active case-finding (ACF) has been suggested as an important complementary strategy to accelerate tuberculosis control especially among high-risk populations. The present exercise aims to develop a model that can be used for county-level project planning. A simple deterministic model was developed to calculate the number of estimated TB cases diagnosed and the associated costs of diagnosis. The model was designed to compare cost-effectiveness parameters, such as the cost per case detected, for different diagnostic algorithms when they are applied to different risk populations. The model was transformed into a web-based tool that can support national TB programmes and civil society partners in designing ACF activities. According to the model output, tuberculosis active case-finding can be a costly endeavor, depending on the target population and the diagnostic strategy. The analysis suggests the following: (1) Active case-finding activities are cost-effective only if the tuberculosis prevalence among the target population is high. (2) Extensive diagnostic methods (e.g. X-ray screening for the entire group, use of sputum culture or molecular diagnostics) can be applied only to very high-risk groups such as TB contacts, prisoners or people living with human immunodeficiency virus (HIV) infection. (3) Basic diagnostic approaches such as TB symptom screening are always applicable although the diagnostic yield is very limited. The cost-effectiveness parameter was sensitive to local diagnostic costs and the tuberculosis prevalence of target populations. The prioritization of appropriate target populations and careful selection of cost-effective diagnostic strategies are critical prerequisites for rational active case-finding activities. A decision to conduct such activities should be based on the setting-specific cost-effectiveness analysis and programmatic assessment. A web-based tool was developed and is available to support national tuberculosis programmes and partners in the formulation of cost-effective active case-finding activities at the national and subnational levels.
2008-01-01
simple,” is the share of airframe structure that is neither tita - nium nor composite material. Unfortunately, only 49 of the 93 aircraft with...of airframe materials (or as simpler materials decrease), aircraft unit cost increases. Increasing the proportion of tita - nium and composite
NASA Astrophysics Data System (ADS)
Hu, Huan; Siu, Vince S.; Gifford, Stacey M.; Kim, Sungcheol; Lu, Minhua; Meyer, Pablo; Stolovitzky, Gustavo A.
2017-12-01
The recently discovered bactericidal properties of nanostructures on wings of insects such as cicadas and dragonflies have inspired the development of similar nanostructured surfaces for antibacterial applications. Since most antibacterial applications require nanostructures covering a considerable amount of area, a practical fabrication method needs to be cost-effective and scalable. However, most reported nanofabrication methods require either expensive equipment or a high temperature process, limiting cost efficiency and scalability. Here, we report a simple, fast, low-cost, and scalable antibacterial surface nanofabrication methodology. Our method is based on metal-assisted chemical etching that only requires etching a single crystal silicon substrate in a mixture of silver nitrate and hydrofluoric acid for several minutes. We experimentally studied the effects of etching time on the morphology of the silicon nanospikes and the bactericidal properties of the resulting surface. We discovered that 6 minutes of etching results in a surface containing silicon nanospikes with optimal geometry. The bactericidal properties of the silicon nanospikes were supported by bacterial plating results, fluorescence images, and scanning electron microscopy images.
Innovative concepts for marginal fields (advanced monotower developments)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, M.T.; Marks, V.E.
1995-12-01
The braced monotower provides a safe, functional and cost effective solution for topsides up to 500 tonnes, with up to 8 wells and standing in water depths of up to 70 meters. It is both simple in concept and structurally efficient. The superstructure is supported by a single column which is stayed by three symmetrically orientated legs. A broad mudline base is also provided to limit pile loads. The final concept offers complete protection to the risers and conductors from ship impact, as all appurtenances are housed within the central column. The basic design philosophy of the low intervention platformmore » is to minimize the onboard equipment to that vitally needed to produce hydrocarbon. The concept eliminates the life support functions that on a normal North Sea platform can contribute up to 50% of the topside dry weight. A system of Zero Based Engineering is used that ensures each item of equipment contributes more to the NPV of the platform than the fully built-up through life cost. This effectively eliminates the operator preference factor and the ``culture`` cost.« less
Low-cost and facile synthesis of Ni(OH)2/ZnO nanostructures for high-sensitivity glucose detection
NASA Astrophysics Data System (ADS)
Strano, V.; Mirabella, S.
2018-01-01
An efficient electrode for non-enzymatic glucose detection is produced with low-cost techniques on a Cu wire. ZnO nanorods (NRs) were grown on a Cu wire by chemical bath deposition and were used as the substrate for pulsed electrodeposition of nanostructured Ni(OH)2 flakes. The effect of the electrodeposition potential on the final morphology and electrochemical behavior of the Ni(OH)2/ZnO/Cu structures is reported. ZnO NRs resulted to be well dressed by Ni(OH)2 flakes and were tested as glucose sensing electrodes in 0.1 M NaOH solution, showing high sensitivities (up to 3 mA mM-1 cm-2) and long-term stability. The presence of ZnO NRs was shown to improve the performance of the glucose sensor in terms of electrochemical stability over the time and sensitivity compared to Ni(OH)2/Cu sample. The reported data demonstrate a simple, versatile and low-cost fabrication approach for effective glucose sensing system within a urban mines framework.
Time-of-Flight Measurement of the Speed of Sound in a Metal Bar
ERIC Educational Resources Information Center
Ganci, Salvatore
2016-01-01
A simple setup was designed for a "time-of-flight" measurement of the sound speed in a metal bar. The experiment requires low cost components and is very simple to understand by students. A good use of it is as a demonstration experiment.
High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory
ERIC Educational Resources Information Center
Frey, Douglas D.; Guo, Hui; Karnik, Nikhila
2013-01-01
This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…
77 FR 3506 - Copyright Office Fees
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-24
... spring. As part of the process of formulating that fee schedule, the Office seeks the views of interested... recognition of the lower cost in processing such simple applications as well as the need to encourage.... There is some precedent for special treatment for simple basic applications by individual authors. Since...
78 FR 71558 - Insurance Cost Information Regulation
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-29
... [Docket No. NHTSA-2013-0078] Insurance Cost Information Regulation AGENCY: National Highway Traffic Safety... method for reporting simple and understandable motor vehicle damage susceptibility information to consumers. NHTSA plans to use this information to meet a requirement by Congress that it study and report...
Cost-effectiveness of different screening strategies for osteoporosis in postmenopausal women.
Nayak, Smita; Roberts, Mark S; Greenspan, Susan L
2011-12-06
The best strategies to screen postmenopausal women for osteoporosis are not clear. To identify the cost-effectiveness of various screening strategies. Individual-level state-transition cost-effectiveness model. Published literature. U.S. women aged 55 years or older. Lifetime. Payer. Screening strategies composed of alternative tests (central dual-energy x-ray absorptiometry [DXA], calcaneal quantitative ultrasonography [QUS], and the Simple Calculated Osteoporosis Risk Estimation [SCORE] tool) initiation ages, treatment thresholds, and rescreening intervals. Oral bisphosphonate treatment was assumed, with a base-case adherence rate of 50% and a 5-year on/off treatment pattern. Incremental cost-effectiveness ratios (2010 U.S. dollars per quality-adjusted life-year [QALY] gained). At all evaluated ages, screening was superior to not screening. In general, quality-adjusted life-days gained with screening tended to increase with age. At all initiation ages, the best strategy with an incremental cost-effectiveness ratio (ICER) of less than $50,000 per QALY was DXA screening with a T-score threshold of -2.5 or less for treatment and with follow-up screening every 5 years. Across screening initiation ages, the best strategy with an ICER less than $50,000 per QALY was initiation of screening at age 55 years by using DXA -2.5 with rescreening every 5 years. The best strategy with an ICER less than $100,000 per QALY was initiation of screening at age 55 years by using DXA with a T-score threshold of -2.0 or less for treatment and then rescreening every 10 years. No other strategy that involved treatment of women with osteopenia had an ICER less than $100,000 per QALY. Many other strategies, including strategies with SCORE or QUS prescreening, were also cost-effective, and in general the differences in effectiveness and costs between evaluated strategies was small. Probabilistic sensitivity analysis did not reveal a consistently superior strategy. Data were primarily from white women. Screening initiation at ages younger than 55 years were not examined. Only osteoporotic fractures of the hip, vertebrae, and wrist were modeled. Many strategies for postmenopausal osteoporosis screening are effective and cost-effective, including strategies involving screening initiation at age 55 years. No strategy substantially outperforms another. National Center for Research Resources.
Cook, Darren A N; Pilotte, Nils; Minetti, Corrado; Williams, Steven A; Reimer, Lisa J
2017-11-06
Background: Molecular xenomonitoring (MX), the testing of insect vectors for the presence of human pathogens, has the potential to provide a non-invasive and cost-effective method for monitoring the prevalence of disease within a community. Current MX methods require the capture and processing of large numbers of mosquitoes, particularly in areas of low endemicity, increasing the time, cost and labour required. Screening the excreta/feces (E/F) released from mosquitoes, rather than whole carcasses, improves the throughput by removing the need to discriminate vector species since non-vectors release ingested pathogens in E/F. It also enables larger numbers of mosquitoes to be processed per pool. However, this new screening approach requires a method of efficiently collecting E/F. Methods: We developed a cone with a superhydrophobic surface to allow for the efficient collection of E/F. Using mosquitoes exposed to either Plasmodium falciparum , Brugia malayi or Trypanosoma brucei brucei, we tested the performance of the superhydrophobic cone alongside two other collection methods. Results: All collection methods enabled the detection of DNA from the three parasites. Using the superhydrophobic cone to deposit E/F into a small tube provided the highest number of positive samples (16 out of 18) and facilitated detection of parasite DNA in E/F from individual mosquitoes. Further tests showed that following a simple washing step, the cone can be reused multiple times, further improving its cost-effectiveness. Conclusions: Incorporating the superhydrophobic cone into mosquito traps or holding containers could provide a simple and efficient method for collecting E/F. Where this is not possible, swabbing the container or using the washing method facilitates the detection of the three parasites used in this study.
One-dimensional acoustic standing waves in rectangular channels for flow cytometry.
Austin Suthanthiraraj, Pearlson P; Piyasena, Menake E; Woods, Travis A; Naivar, Mark A; Lόpez, Gabriel P; Graves, Steven W
2012-07-01
Flow cytometry has become a powerful analytical tool for applications ranging from blood diagnostics to high throughput screening of molecular assemblies on microsphere arrays. However, instrument size, expense, throughput, and consumable use limit its use in resource poor areas of the world, as a component in environmental monitoring, and for detection of very rare cell populations. For these reasons, new technologies to improve the size and cost-to-performance ratio of flow cytometry are required. One such technology is the use of acoustic standing waves that efficiently concentrate cells and particles to the center of flow channels for analysis. The simplest form of this method uses one-dimensional acoustic standing waves to focus particles in rectangular channels. We have developed one-dimensional acoustic focusing flow channels that can be fabricated in simple capillary devices or easily microfabricated using photolithography and deep reactive ion etching. Image and video analysis demonstrates that these channels precisely focus single flowing streams of particles and cells for traditional flow cytometry analysis. Additionally, use of standing waves with increasing harmonics and in parallel microfabricated channels is shown to effectively create many parallel focused streams. Furthermore, we present the fabrication of an inexpensive optical platform for flow cytometry in rectangular channels and use of the system to provide precise analysis. The simplicity and low-cost of the acoustic focusing devices developed here promise to be effective for flow cytometers that have reduced size, cost, and consumable use. Finally, the straightforward path to parallel flow streams using one-dimensional multinode acoustic focusing, indicates that simple acoustic focusing in rectangular channels may also have a prominent role in high-throughput flow cytometry. Copyright © 2012 Elsevier Inc. All rights reserved.
Development of longitudinally excited CO2 laser
NASA Astrophysics Data System (ADS)
Masroon, N. S.; Tanaka, M.; Tei, M.; Uno, K.; Tsuyama, M.; Nakano, H.
2018-05-01
Simple, compact, and affordable discharged-pumped CO2 laser controlled by a fast high voltage solid state switch has been developed. In this study, longitudinal excitation scheme has been adapted for simple configuration. In the longitudinal excitation scheme, the discharge is produced along the direction of the laser axis, and the electrodes are well separated with a small discharge cross-section. Triggered spark gap switch is usually used to switch out the high voltage because of simple and low cost. However, the triggered spark gap operates in the arc mode and suffer from recovery problem causing a short life time and low efficiency for high repetition rate operation. As a result, there is now considerable interest in replacing triggered spark gap switch with solid state switches. Solid state switches have significant advantages compared to triggered spark gap switch which include longer service lifetime, low cost and stable high trigger pulse. We have developed simple and low cost fast high voltage solid state switch that consists of series connected-MOSFETs. It has been installed to the longitudinally excited CO2 laser to realize the gap switch less operation. Characteristics of laser oscillation by varying the discharge length, charging voltage, capacitance and gas pressure have been evaluated. Longer discharge length produce high power of laser oscillation. Optimum charging voltage and gas pressure were existed for longitudinally excited CO2 laser.
A simple circuit to deliver bubbling CPAP.
Kaur, Charanjit; Sema, Akatoli; Beri, Rajbir S; Puliyel, Jacob M
2008-04-01
Nasal continuous positive airway pressure (CPAP), especially bubbling CPAP, is known to reduce the need for more invasive ventilation. We here describe a circuit that can deliver bubbling CPAP in resource poor settings. We describe how the oxygen concentration can be altered from 98% to 21% oxygen using this system. Addition of a humidifier in the circuit has the effect of reducing the oxygen concentration by 1 to 5%. The cost of putting together the system is approximately Rs 5000.
Li, Guimin; Li, Wangfeng; Liu, Lixia
2012-01-01
Real-time PCR has engendered wide acceptance for quantitation of hepatitis B virus (HBV) DNA in the blood due to its improved rapidity, sensitivity, reproducibility, and reduced contamination. Here we describe a cost-effective and highly sensitive HBV real-time quantitative assay based on the light upon extension real-time PCR platform and a simple and reliable HBV DNA preparation method using silica-coated magnetic beads.
High Frontier: The Journal for Space and Missile Professionals. Volume 7, Number 1, November 2010
2010-11-01
effect on their decision calculus . The predictability of our response—and their accounting for it—was a part of their cost/ benefit trade space well...national leadership’s decision calculus , there is one simple point of clarity about nuclear deterrence that transcends all of the variables: your...Together with more inci- dental situations of entanglement (e.g., when services are shared on a commercial bearer), these common systems create a
Interface design principles for high-performance organic semiconductor devices
Nie, Wanyi; Gupta, Gautam; Crone, Brian K.; ...
2015-03-23
Organic solar cells (OSCs) are a promising cost-effective candidate in next generation photovoltaic technology. However, a critical bottleneck for OSCs is the electron/hole recombination loss through charge transfer state at the interface, which greatly limits the power conversion efficiency. W. Nie, A. Mohite, and co-workers demonstrate a simple strategy of suppressing the recombination rate by inserting a spacer layer at the donor-acceptor interface, resulting in a dramatic increase in power conversion efficiency.
Imaging of acoustic fields using optical feedback interferometry.
Bertling, Karl; Perchoux, Julien; Taimre, Thomas; Malkin, Robert; Robert, Daniel; Rakić, Aleksandar D; Bosch, Thierry
2014-12-01
This study introduces optical feedback interferometry as a simple and effective technique for the two-dimensional visualisation of acoustic fields. We present imaging results for several pressure distributions including those for progressive waves, standing waves, as well as the diffraction and interference patterns of the acoustic waves. The proposed solution has the distinct advantage of extreme optical simplicity and robustness thus opening the way to a low cost acoustic field imaging system based on mass produced laser diodes.
A pipette-based calibration system for fast-scan cyclic voltammetry with fast response times.
Ramsson, Eric S
2016-01-01
Fast-scan cyclic voltammetry (FSCV) is an electrochemical technique that utilizes the oxidation and/or reduction of an analyte of interest to infer rapid changes in concentrations. In order to calibrate the resulting oxidative or reductive current, known concentrations of an analyte must be introduced under controlled settings. Here, I describe a simple and cost-effective method, using a Petri dish and pipettes, for the calibration of carbon fiber microelectrodes (CFMs) using FSCV.
NASA Astrophysics Data System (ADS)
Dhanavel, S.; Nivethaa, E. A. K.; Esther, G.; Narayanan, V.; Stephen, A.
2016-05-01
Chitosan supported Palladium nanoparticles were synthesized by a simple cost effective chemical reduction method using NaBH4. The prepared nanocomposite was characterized by X-Ray diffraction analysis, FESEM and Energy dispersive spectroscopy analysis of X-rays (EDAX). The catalytic performance of the nanocomposite was evaluated on the reduction of 2-Nitrophenol to the 2-Amino phenol with rate constant 1.08 × 10-3 S-1 by NaBH4 using Spectrophotometer.
A Nuclear Waste Management Cost Model for Policy Analysis
NASA Astrophysics Data System (ADS)
Barron, R. W.; Hill, M. C.
2017-12-01
Although integrated assessments of climate change policy have frequently identified nuclear energy as a promising alternative to fossil fuels, these studies have often treated nuclear waste disposal very simply. Simple assumptions about nuclear waste are problematic because they may not be adequate to capture relevant costs and uncertainties, which could result in suboptimal policy choices. Modeling nuclear waste management costs is a cross-disciplinary, multi-scale problem that involves economic, geologic and environmental processes that operate at vastly different temporal scales. Similarly, the climate-related costs and benefits of nuclear energy are dependent on environmental sensitivity to CO2 emissions and radiation, nuclear energy's ability to offset carbon emissions, and the risk of nuclear accidents, factors which are all deeply uncertain. Alternative value systems further complicate the problem by suggesting different approaches to valuing intergenerational impacts. Effective policy assessment of nuclear energy requires an integrated approach to modeling nuclear waste management that (1) bridges disciplinary and temporal gaps, (2) supports an iterative, adaptive process that responds to evolving understandings of uncertainties, and (3) supports a broad range of value systems. This work develops the Nuclear Waste Management Cost Model (NWMCM). NWMCM provides a flexible framework for evaluating the cost of nuclear waste management across a range of technology pathways and value systems. We illustrate how NWMCM can support policy analysis by estimating how different nuclear waste disposal scenarios developed using the NWMCM framework affect the results of a recent integrated assessment study of alternative energy futures and their effects on the cost of achieving carbon abatement targets. Results suggest that the optimism reflected in previous works is fragile: Plausible nuclear waste management costs and discount rates appropriate for intergenerational cost-benefit analysis produce many scenarios where nuclear energy is economically unattractive.
Wang, Zhihong; Cao, Fenhui; Chen, Kongfa; Yan, Yingming; Chen, Yifu; Zhang, Yaohui; Zhu, Xingbao; Wei, Bo; Xiong, Yueping; Lv, Zhe
2018-03-09
Cellular metals with the large surface/volume ratios and excellent electrical conductivity are widely applicable and have thus been studied extensively. It is highly desirable to develop a facile and cost-effective process for fabrication of porous metallic structures, and yet more so for micro/nanoporous structures. A direct-flame strategy is developed for in situ fabrication of micron-scale cellular architecture on a Ni metal precursor. The flame provides the required heat and also serves as a fuel reformer, which provides a gas mixture of H 2 , CO, and O 2 for redox treatment of metallic Ni. The redox processes at elevated temperatures allow fast reconstruction of the metal, leading to a cellular structure on Ni wire. This process is simple and clean and avoids the use of sacrificial materials or templates. Furthermore, nanocrystalline MnO 2 is coated on the microporous Ni wire (MPNW) to form a supercapacitor electrode. The MnO 2 /MPNW electrode and the corresponding fiber-shaped supercapacitor exhibit high specific capacitance and excellent cycling stability. Moreover, this work provides a novel strategy for the fabrication of cellular metals and alloys for a variety of applications, including catalysis, energy storage and conversion, and chemical sensing. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Xiong, Ai-Sheng; Yao, Quan-Hong; Peng, Ri-He; Li, Xian; Fan, Hui-Qin; Cheng, Zong-Ming; Li, Yi
2004-07-07
Chemical synthesis of DNA sequences provides a powerful tool for modifying genes and for studying gene function, structure and expression. Here, we report a simple, high-fidelity and cost-effective PCR-based two-step DNA synthesis (PTDS) method for synthesis of long segments of DNA. The method involves two steps. (i) Synthesis of individual fragments of the DNA of interest: ten to twelve 60mer oligonucleotides with 20 bp overlap are mixed and a PCR reaction is carried out with high-fidelity DNA polymerase Pfu to produce DNA fragments that are approximately 500 bp in length. (ii) Synthesis of the entire sequence of the DNA of interest: five to ten PCR products from the first step are combined and used as the template for a second PCR reaction using high-fidelity DNA polymerase pyrobest, with the two outermost oligonucleotides as primers. Compared with the previously published methods, the PTDS method is rapid (5-7 days) and suitable for synthesizing long segments of DNA (5-6 kb) with high G + C contents, repetitive sequences or complex secondary structures. Thus, the PTDS method provides an alternative tool for synthesizing and assembling long genes with complex structures. Using the newly developed PTDS method, we have successfully obtained several genes of interest with sizes ranging from 1.0 to 5.4 kb.
NASA Astrophysics Data System (ADS)
Suresh, K.; Balaji, S.; Saravanan, K.; Navas, J.; David, C.; Panigrahi, B. K.
2018-02-01
We developed a simple, low cost user-friendly automated indirect ion beam fluence measurement system for ion irradiation and analysis experiments requiring indirect beam fluence measurements unperturbed by sample conditions like low temperature, high temperature, sample biasing as well as in regular ion implantation experiments in the ion implanters and electrostatic accelerators with continuous beam. The system, which uses simple, low cost, off-the-shelf components/systems and two distinct layers of in-house built softwarenot only eliminates the need for costly data acquisition systems but also overcomes difficulties in using properietry software. The hardware of the system is centered around a personal computer, a PIC16F887 based embedded system, a Faraday cup drive cum monitor circuit, a pair of Faraday Cups and a beam current integrator and the in-house developed software include C based microcontroller firmware and LABVIEW based virtual instrument automation software. The automatic fluence measurement involves two important phases, a current sampling phase lasting over 20-30 seconds during which the ion beam current is continuously measured by intercepting the ion beam and the averaged beam current value is computed. A subsequent charge computation phase lasting 700-900 seconds is executed making the ion beam to irradiate the samples and the incremental fluence received by the sampleis estimated usingthe latest averaged beam current value from the ion beam current sampling phase. The cycle of current sampling-charge computation is repeated till the required fluence is reached. Besides simplicity and cost-effectiveness, other important advantages of the developed system include easy reconfiguration of the system to suit customisation of experiments, scalability, easy debug and maintenance of the hardware/software, ability to work as a standalone system. The system was tested with different set of samples and ion fluences and the results were verified using Rutherford backscattering technique which showed the satisfactory functioning of the system. The accuracy of the fluence measurements is found to be less than 2% which meets the demands of the irradiation experiments undertaken using the developed set up. The system was incorporated for regular use at the existing ultra high vacuum (UHV) ion irradiation chamber of 1.7 MV Tandem accelerator and several ion implantation experiments on a variety of samples like SS304, D9, ODS alloys have been successfully carried out.
L-band mobile terminal antennas for helicopters
NASA Technical Reports Server (NTRS)
Wu, T. K.; Farazian, K.; Golshan, N.; Divsalar, D.; Hinedi, S.
1993-01-01
The feasibility of using a low gain antenna (LGA) as a mobile terminal antenna for a helicopter is described in this paper. The objectives are to select the lowest cost antenna system which can be easily mounted on a helicopter and capable of communicating with a satellite, and to determine the best antenna position on the helicopter to mitigate the signal blockage due to rotor blades and the multipath effect from the helicopter's body. The omnidirectional LGA is selected because it is simple, reliable, and low cost. The helix antenna is selected among the many LGA's because it is the most economical one and has the widest elevation beamwidth. Both 2-arm and 4-arm helices are studied experimentally to determine the antenna's performance and the scattering effects from the helicopter's body. It is found that the LGA should be located near the tail section and at least eight inches above the helicopter.